  1. Accuracy of active chirp linearization for broadband frequency modulated continuous wave ladar.

    PubMed

    Barber, Zeb W; Babbitt, Wm Randall; Kaylor, Brant; Reibel, Randy R; Roos, Peter A

    2010-01-10

    As the bandwidth and linearity of frequency modulated continuous wave chirp ladar increase, the resulting range resolution, precisions, and accuracy are improved correspondingly. An analysis of a very broadband (several THz) and linear (<1 ppm) chirped ladar system based on active chirp linearization is presented. Residual chirp nonlinearity and material dispersion are analyzed as to their effect on the dynamic range, precision, and accuracy of the system. Measurement precision and accuracy approaching the part per billion level is predicted.

  2. Precision Linear Actuator for Space Interferometry Mission (SIM) Siderostat Pointing

    NASA Technical Reports Server (NTRS)

    Cook, Brant; Braun, David; Hankins, Steve; Koenig, John; Moore, Don

    2008-01-01

    'SIM PlanetQuest will exploit the classical measuring tool of astrometry (interferometry) with unprecedented precision to make dramatic advances in many areas of astronomy and astrophysics'(1). In order to obtain interferometric data two large steerable mirrors, or Siderostats, are used to direct starlight into the interferometer. A gimbaled mechanism actuated by linear actuators is chosen to meet the unprecedented pointing and angle tracking requirements of SIM. A group of JPL engineers designed, built, and tested a linear ballscrew actuator capable of performing submicron incremental steps for 10 years of continuous operation. Precise, zero backlash, closed loop pointing control requirements, lead the team to implement a ballscrew actuator with a direct drive DC motor and a precision piezo brake. Motor control commutation using feedback from a precision linear encoder on the ballscrew output produced an unexpected incremental step size of 20 nm over a range of 120 mm, yielding a dynamic range of 6,000,000:1. The results prove linear nanometer positioning requires no gears, levers, or hydraulic converters. Along the way many lessons have been learned and will subsequently be shared.

  3. Research on precise pneumatic-electric displacement sensor with large measurement range

    NASA Astrophysics Data System (ADS)

    Yin, Zhehao; Yuan, Yibao; Liu, Baoshuai

    2017-10-01

    This research mainly focuses on precise pneumatic-electric displacement sensor which has large measurement range. Under the high precision, measurement range can be expanded so that the need of high precision as well as large range can be satisfied in the field of machining inspection technology. This research was started by the analysis of pneumatic-measuring theory. Then, an gas circuit measuring system which is based on differential pressure was designed. This designed system can reach two aims: Firstly, to convert displacement signal into gas signal; Secondly, to reduce the measurement error which caused by pressure and environmental turbulence. Furthermore, in consideration of the high requirement for linearity, sensitivity and stability, the project studied the pneumatic-electric transducer which puts the SCX series pressure sensor as a key part. The main purpose of this pneumatic-electric transducer is to convert gas signal to suitable electrical signal. Lastly, a broken line subsection linearization circuit was designed, which can nonlinear correct the output characteristic curve so as to enlarge the linear measurement range. The final result could be briefly described like this: under the condition that measuring error is less than 1μm, measurement range could be extended to approximately 200μm which is much higher than the measurement range of traditional pneumatic measuring instrument. Meanwhile, it can reach higher exchangeability and stability in order to become more suitable to engineering application.

  4. Sample Introduction Using the Hildebrand Grid Nebulizer for Plasma Spectrometry

    DTIC Science & Technology

    1988-01-01

    linear dynamic ranges, precision, and peak width were de- termined for elements in methanol and acetonitrile solutions. , (1)> The grid nebulizer was...FIA) with ICP-OES detection were evaluated. Detec- tion limits, linear dynamic ranges, precision, and peak width were de- termined for elements in...Concentration vs. Log Peak Area for Mn, 59 Cd, Zn, Au, Ni in Methanol (CMSC) 3-28 Log Concentration vs. Log Peak Area for Mn, 60 Cd, Au, Ni in

  5. A phase match based frequency estimation method for sinusoidal signals

    NASA Astrophysics Data System (ADS)

    Shen, Yan-Lin; Tu, Ya-Qing; Chen, Lin-Jun; Shen, Ting-Ao

    2015-04-01

    Accurate frequency estimation affects the ranging precision of linear frequency modulated continuous wave (LFMCW) radars significantly. To improve the ranging precision of LFMCW radars, a phase match based frequency estimation method is proposed. To obtain frequency estimation, linear prediction property, autocorrelation, and cross correlation of sinusoidal signals are utilized. The analysis of computational complex shows that the computational load of the proposed method is smaller than those of two-stage autocorrelation (TSA) and maximum likelihood. Simulations and field experiments are performed to validate the proposed method, and the results demonstrate the proposed method has better performance in terms of frequency estimation precision than methods of Pisarenko harmonic decomposition, modified covariance, and TSA, which contribute to improving the precision of LFMCW radars effectively.

  6. Improved measurement linearity and precision for AMCW time-of-flight range imaging cameras.

    PubMed

    Payne, Andrew D; Dorrington, Adrian A; Cree, Michael J; Carnegie, Dale A

    2010-08-10

    Time-of-flight range imaging systems utilizing the amplitude modulated continuous wave (AMCW) technique often suffer from measurement nonlinearity due to the presence of aliased harmonics within the amplitude modulation signals. Typically a calibration is performed to correct these errors. We demonstrate an alternative phase encoding approach that attenuates the harmonics during the sampling process, thereby improving measurement linearity in the raw measurements. This mitigates the need to measure the system's response or calibrate for environmental changes. In conjunction with improved linearity, we demonstrate that measurement precision can also be increased by reducing the duty cycle of the amplitude modulated illumination source (while maintaining overall illumination power).

  7. Influence of Waveform Characteristics on LiDAR Ranging Accuracy and Precision

    PubMed Central

    Yang, Bingwei; Xie, Xinhao; Li, Duan

    2018-01-01

    Time of flight (TOF) based light detection and ranging (LiDAR) is a technology for calculating distance between start/stop signals of time of flight. In lab-built LiDAR, two ranging systems for measuring flying time between start/stop signals include time-to-digital converter (TDC) that counts time between trigger signals and analog-to-digital converter (ADC) that processes the sampled start/stop pulses waveform for time estimation. We study the influence of waveform characteristics on range accuracy and precision of two kinds of ranging system. Comparing waveform based ranging (WR) with analog discrete return system based ranging (AR), a peak detection method (WR-PK) shows the best ranging performance because of less execution time, high ranging accuracy, and stable precision. Based on a novel statistic mathematical method maximal information coefficient (MIC), WR-PK precision has a high linear relationship with the received pulse width standard deviation. Thus keeping the received pulse width of measuring a constant distance as stable as possible can improve ranging precision. PMID:29642639

  8. Precision Interval Estimation of the Response Surface by Means of an Integrated Algorithm of Neural Network and Linear Regression

    NASA Technical Reports Server (NTRS)

    Lo, Ching F.

    1999-01-01

    The integration of Radial Basis Function Networks and Back Propagation Neural Networks with the Multiple Linear Regression has been accomplished to map nonlinear response surfaces over a wide range of independent variables in the process of the Modem Design of Experiments. The integrated method is capable to estimate the precision intervals including confidence and predicted intervals. The power of the innovative method has been demonstrated by applying to a set of wind tunnel test data in construction of response surface and estimation of precision interval.

  9. [Determination of tungsten and cobalt in the air of workplace by ICP-OES].

    PubMed

    Zhang, J; Ding, C G; Li, H B; Song, S; Yan, H F

    2017-08-20

    Objective: To establish the inductively coupled plasma optical emission spectrometry (ICP-OES) method for determination of cobalt and tungsten in the air of workplace. Methods: The cobalt and tungsten were collected by filter membrane and then digested by nitric acid, inductively coupled plasma optical emission spectrometry (ICP-OES) was used for the detection of cobalt and tungsten. Results: The linearity of tungsten was good at the range of 0.01-1 000 μg/ml with a correlation coefficient of 0.999 9, the LOD and LOQ were 0.006 7 μg/ml and 0.022 μg/ml, respectively. The recovery was ranged from 98%-101%, the RSD of intra-and inter-batch precision were 1.1%-3.0% and 2.1%-3.8%, respectively. The linearity of cobalt was good at the range of 0.01-100 μg/ml with a correlation coefficient of 0.999 9, the LOD and LOQ were 0.001 2 μg/ml and 0.044 μg/ml, respectively. The recovery was ranged from 95%-97%, the RSD of intra-and inter-batch precision were 1.1%-2.4% and 1.1%-2.9%, respectively. The sampling efficiency of tungsten and cobalt were higher than 94%. Conclusion: The linear range, sensitivity and precision of the method was suitable for the detection of tungsten and cobalt in the air of workplace.

  10. Design and implementation of a novel rotary micropositioning system driven by linear voice coil motor.

    PubMed

    Xu, Qingsong

    2013-05-01

    Limited-angle rotary micropositioning stages are required in precision engineering applications where an ultrahigh-precision rotational motion within a restricted range is needed. This paper presents the design, fabrication, and control of a compliant rotary micropositioning stage dedicated to the said applications. To tackle the challenge of achieving both a large rotational range and a compact size, a new idea of multi-stage compound radial flexure is proposed. A compact rotary stage is devised to deliver an over 10° rotational range while possessing a negligible magnitude of center shift. The stage is driven by a linear voice coil motor and its output motion is measured by laser displacement sensors. Analytical models are derived to facilitate the parametric design, which is validated by conducting finite element analysis. The actuation and sensing issues are addressed to guarantee the stage performance. A prototype is fabricated and a proportional-integral-derivative control is implemented to achieve a precise positioning. Experimental results demonstrate a resolution of 2 μrad over 10° rotational range as well as a low level of center shift of the rotary micropositioning system.

  11. Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil

    PubMed Central

    Tandon, Shishir; Kumar, Satyendra; Sand, N. K.

    2015-01-01

    This paper aims at developing and validating a convenient, rapid, and sensitive method for estimation of metamitron from soil samples.Determination andquantification was carried out by Gas Chromatography on microcapillary column with an Electron Capture Detector source. The compound was extracted from soil using methanol and cleanup by C-18 SPE. After optimization, the method was validated by evaluating the analytical curves, linearity, limits of detection, and quantification, precision (repeatability and intermediate precision), and accuracy (recovery). Recovery values ranged from 89 to 93.5% within 0.05- 2.0 µg L−1 with average RSD 1.80%. The precision (repeatability) ranged from 1.7034 to 1.9144% and intermediate precision from 1.5685 to 2.1323%. Retention time was 6.3 minutes, and minimum detectable and quantifiable limits were 0.02 ng mL−1 and 0.05 ng g−1, respectively. Good linearity (R 2 = 0.998) of the calibration curves was obtained over the range from 0.05 to 2.0 µg L−1. Results indicated that the developed method is rapid and easy to perform, making it applicable for analysis in large pesticide monitoring programmes. PMID:25733978

  12. Accurate determination of reference materials and natural isolates by means of quantitative (1)h NMR spectroscopy.

    PubMed

    Frank, Oliver; Kreissl, Johanna Karoline; Daschner, Andreas; Hofmann, Thomas

    2014-03-26

    A fast and precise proton nuclear magnetic resonance (qHNMR) method for the quantitative determination of low molecular weight target molecules in reference materials and natural isolates has been validated using ERETIC 2 (Electronic REference To access In vivo Concentrations) based on the PULCON (PULse length based CONcentration determination) methodology and compared to the gravimetric results. Using an Avance III NMR spectrometer (400 MHz) equipped with a broad band observe (BBO) probe, the qHNMR method was validated by determining its linearity, range, precision, and accuracy as well as robustness and limit of quantitation. The linearity of the method was assessed by measuring samples of l-tyrosine, caffeine, or benzoic acid in a concentration range between 0.3 and 16.5 mmol/L (r(2) ≥ 0.99), whereas the interday and intraday precisions were found to be ≤2%. The recovery of a range of reference compounds was ≥98.5%, thus demonstrating the qHNMR method as a precise tool for the rapid quantitation (~15 min) of food-related target compounds in reference materials and natural isolates such as nucleotides, polyphenols, or cyclic peptides.

  13. Computing Generalized Matrix Inverse on Spiking Neural Substrate.

    PubMed

    Shukla, Rohit; Khoram, Soroosh; Jorgensen, Erik; Li, Jing; Lipasti, Mikko; Wright, Stephen

    2018-01-01

    Emerging neural hardware substrates, such as IBM's TrueNorth Neurosynaptic System, can provide an appealing platform for deploying numerical algorithms. For example, a recurrent Hopfield neural network can be used to find the Moore-Penrose generalized inverse of a matrix, thus enabling a broad class of linear optimizations to be solved efficiently, at low energy cost. However, deploying numerical algorithms on hardware platforms that severely limit the range and precision of representation for numeric quantities can be quite challenging. This paper discusses these challenges and proposes a rigorous mathematical framework for reasoning about range and precision on such substrates. The paper derives techniques for normalizing inputs and properly quantizing synaptic weights originating from arbitrary systems of linear equations, so that solvers for those systems can be implemented in a provably correct manner on hardware-constrained neural substrates. The analytical model is empirically validated on the IBM TrueNorth platform, and results show that the guarantees provided by the framework for range and precision hold under experimental conditions. Experiments with optical flow demonstrate the energy benefits of deploying a reduced-precision and energy-efficient generalized matrix inverse engine on the IBM TrueNorth platform, reflecting 10× to 100× improvement over FPGA and ARM core baselines.

  14. Linear FMCW Laser Radar for Precision Range and Vector Velocity Measurements

    NASA Technical Reports Server (NTRS)

    Pierrottet, Diego; Amzajerdian, Farzin; Petway, Larry; Barnes, Bruce; Lockhard, George; Rubio, Manuel

    2008-01-01

    An all fiber linear frequency modulated continuous wave (FMCW) coherent laser radar system is under development with a goal to aide NASA s new Space Exploration initiative for manned and robotic missions to the Moon and Mars. By employing a combination of optical heterodyne and linear frequency modulation techniques and utilizing state-of-the-art fiber optic technologies, highly efficient, compact and reliable laser radar suitable for operation in a space environment is being developed. Linear FMCW lidar has the capability of high-resolution range measurements, and when configured into a multi-channel receiver system it has the capability of obtaining high precision horizontal and vertical velocity measurements. Precision range and vector velocity data are beneficial to navigating planetary landing pods to the preselected site and achieving autonomous, safe soft-landing. The all-fiber coherent laser radar has several important advantages over more conventional pulsed laser altimeters or range finders. One of the advantages of the coherent laser radar is its ability to measure directly the platform velocity by extracting the Doppler shift generated from the motion, as opposed to time of flight range finders where terrain features such as hills, cliffs, or slopes add error to the velocity measurement. Doppler measurements are about two orders of magnitude more accurate than the velocity estimates obtained by pulsed laser altimeters. In addition, most of the components of the device are efficient and reliable commercial off-the-shelf fiber optic telecommunication components. This paper discusses the design and performance of a second-generation brassboard system under development at NASA Langley Research Center as part of the Autonomous Landing and Hazard Avoidance (ALHAT) project.

  15. Video-rate or high-precision: a flexible range imaging camera

    NASA Astrophysics Data System (ADS)

    Dorrington, Adrian A.; Cree, Michael J.; Carnegie, Dale A.; Payne, Andrew D.; Conroy, Richard M.; Godbaz, John P.; Jongenelen, Adrian P. P.

    2008-02-01

    A range imaging camera produces an output similar to a digital photograph, but every pixel in the image contains distance information as well as intensity. This is useful for measuring the shape, size and location of objects in a scene, hence is well suited to certain machine vision applications. Previously we demonstrated a heterodyne range imaging system operating in a relatively high resolution (512-by-512) pixels and high precision (0.4 mm best case) configuration, but with a slow measurement rate (one every 10 s). Although this high precision range imaging is useful for some applications, the low acquisition speed is limiting in many situations. The system's frame rate and length of acquisition is fully configurable in software, which means the measurement rate can be increased by compromising precision and image resolution. In this paper we demonstrate the flexibility of our range imaging system by showing examples of high precision ranging at slow acquisition speeds and video-rate ranging with reduced ranging precision and image resolution. We also show that the heterodyne approach and the use of more than four samples per beat cycle provides better linearity than the traditional homodyne quadrature detection approach. Finally, we comment on practical issues of frame rate and beat signal frequency selection.

  16. Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast-enhanced MRI.

    PubMed

    Kallehauge, Jesper F; Sourbron, Steven; Irving, Benjamin; Tanderup, Kari; Schnabel, Julia A; Chappell, Michael A

    2017-06-01

    Fitting tracer kinetic models using linear methods is much faster than using their nonlinear counterparts, although this comes often at the expense of reduced accuracy and precision. The aim of this study was to derive and compare the performance of the linear compartmental tissue uptake (CTU) model with its nonlinear version with respect to their percentage error and precision. The linear and nonlinear CTU models were initially compared using simulations with varying noise and temporal sampling. Subsequently, the clinical applicability of the linear model was demonstrated on 14 patients with locally advanced cervical cancer examined with dynamic contrast-enhanced magnetic resonance imaging. Simulations revealed equal percentage error and precision when noise was within clinical achievable ranges (contrast-to-noise ratio >10). The linear method was significantly faster than the nonlinear method, with a minimum speedup of around 230 across all tested sampling rates. Clinical analysis revealed that parameters estimated using the linear and nonlinear CTU model were highly correlated (ρ ≥ 0.95). The linear CTU model is computationally more efficient and more stable against temporal downsampling, whereas the nonlinear method is more robust to variations in noise. The two methods may be used interchangeably within clinical achievable ranges of temporal sampling and noise. Magn Reson Med 77:2414-2423, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  17. Double Arm Linkage precision Linear motion (DALL) Carriage, a simplified, rugged, high performance linear motion stage for the moving mirror of an Fourier Transform Spectrometer or other system requiring precision linear motion

    NASA Astrophysics Data System (ADS)

    Johnson, Kendall B.; Hopkins, Greg

    2017-08-01

    The Double Arm Linkage precision Linear motion (DALL) carriage has been developed as a simplified, rugged, high performance linear motion stage. Initially conceived as a moving mirror stage for the moving mirror of a Fourier Transform Spectrometer (FTS), it is applicable to any system requiring high performance linear motion. It is based on rigid double arm linkages connecting a base to a moving carriage through flexures. It is a monolithic design. The system is fabricated from one piece of material including the flexural elements, using high precision machining. The monolithic design has many advantages. There are no joints to slip or creep and there are no CTE (coefficient of thermal expansion) issues. This provides a stable, robust design, both mechanically and thermally and is expected to provide a wide operating temperature range, including cryogenic temperatures, and high tolerance to vibration and shock. Furthermore, it provides simplicity and ease of implementation, as there is no assembly or alignment of the mechanism. It comes out of the machining operation aligned and there are no adjustments. A prototype has been fabricated and tested, showing superb shear performance and very promising tilt performance. This makes it applicable to both corner cube and flat mirror FTS systems respectively.

  18. Multi-center evaluation of analytical performance of the Beckman Coulter AU5822 chemistry analyzer.

    PubMed

    Zimmerman, M K; Friesen, L R; Nice, A; Vollmer, P A; Dockery, E A; Rankin, J D; Zmuda, K; Wong, S H

    2015-09-01

    Our three academic institutions, Indiana University, Northwestern Memorial Hospital, and Wake Forest, were among the first in the United States to implement the Beckman Coulter AU5822 series chemistry analyzers. We undertook this post-hoc multi-center study by merging our data to determine performance characteristics and the impact of methodology changes on analyte measurement. We independently completed performance validation studies including precision, linearity/analytical measurement range, method comparison, and reference range verification. Complete data sets were available from at least one institution for 66 analytes with the following groups: 51 from all three institutions, and 15 from 1 or 2 institutions for a total sample size of 12,064. Precision was similar among institutions. Coefficients of variation (CV) were <10% for 97%. Analytes with CVs >10% included direct bilirubin and digoxin. All analytes exhibited linearity over the analytical measurement range. Method comparison data showed slopes between 0.900-1.100 for 87.9% of the analytes. Slopes for amylase, tobramycin and urine amylase were <0.8; the slope for lipase was >1.5, due to known methodology or standardization differences. Consequently, reference ranges of amylase, urine amylase and lipase required only minor or no modification. The four AU5822 analyzers independently evaluated at three sites showed consistent precision, linearity, and correlation results. Since installations, the test results had been well received by clinicians from all three institutions. Copyright © 2015. Published by Elsevier Inc.

  19. Computing Generalized Matrix Inverse on Spiking Neural Substrate

    PubMed Central

    Shukla, Rohit; Khoram, Soroosh; Jorgensen, Erik; Li, Jing; Lipasti, Mikko; Wright, Stephen

    2018-01-01

    Emerging neural hardware substrates, such as IBM's TrueNorth Neurosynaptic System, can provide an appealing platform for deploying numerical algorithms. For example, a recurrent Hopfield neural network can be used to find the Moore-Penrose generalized inverse of a matrix, thus enabling a broad class of linear optimizations to be solved efficiently, at low energy cost. However, deploying numerical algorithms on hardware platforms that severely limit the range and precision of representation for numeric quantities can be quite challenging. This paper discusses these challenges and proposes a rigorous mathematical framework for reasoning about range and precision on such substrates. The paper derives techniques for normalizing inputs and properly quantizing synaptic weights originating from arbitrary systems of linear equations, so that solvers for those systems can be implemented in a provably correct manner on hardware-constrained neural substrates. The analytical model is empirically validated on the IBM TrueNorth platform, and results show that the guarantees provided by the framework for range and precision hold under experimental conditions. Experiments with optical flow demonstrate the energy benefits of deploying a reduced-precision and energy-efficient generalized matrix inverse engine on the IBM TrueNorth platform, reflecting 10× to 100× improvement over FPGA and ARM core baselines. PMID:29593483

  20. Simultaneous Determination of Piperine, Capsaicin, and Dihydrocapsaicin in Korean Instant-Noodle (Ramyun) Soup Base Using High-Performance Liquid Chromatography with Ultraviolet Detection.

    PubMed

    Shim, You-Shin; Kim, Jong-Chan; Jeong, Seung-Weon

    2016-01-01

    A simultaneous analytical method for piperine, capsaicin, and dihydrocapsaicin in Korean instant-noodle soup base using HPLC was validated in terms of precision, accuracy, sensitivity, and linearity. The HPLC separation was performed on a reversed-phase C18 column (5 μm particle size, 4.6 mm id, 250 mm length) using a UV detector fixed at 280 nm. The LOD and LOQ of the HPLC analyses ranged from 0.25 to 1.03 mg/kg. The intraday and interday precisions of the individual piperine, capsaicin, and dihydrocapsaicin were <10.55%, and the recovery values ranged from 85.43 to 94.68%. The calibration curves exhibited good linearity (r(2) = 0.999) within the tested ranges. These results suggest that the analytical method in this study can be used to classify Korean instant noodles based on their levels of spiciness.

  1. The fastclime Package for Linear Programming and Large-Scale Precision Matrix Estimation in R.

    PubMed

    Pang, Haotian; Liu, Han; Vanderbei, Robert

    2014-02-01

    We develop an R package fastclime for solving a family of regularized linear programming (LP) problems. Our package efficiently implements the parametric simplex algorithm, which provides a scalable and sophisticated tool for solving large-scale linear programs. As an illustrative example, one use of our LP solver is to implement an important sparse precision matrix estimation method called CLIME (Constrained L 1 Minimization Estimator). Compared with existing packages for this problem such as clime and flare, our package has three advantages: (1) it efficiently calculates the full piecewise-linear regularization path; (2) it provides an accurate dual certificate as stopping criterion; (3) it is completely coded in C and is highly portable. This package is designed to be useful to statisticians and machine learning researchers for solving a wide range of problems.

  2. Strategy for Realizing High-Precision VUV Spectro-Polarimeter

    NASA Astrophysics Data System (ADS)

    Ishikawa, R.; Narukage, N.; Kubo, M.; Ishikawa, S.; Kano, R.; Tsuneta, S.

    2014-12-01

    Spectro-polarimetric observations in the vacuum ultraviolet (VUV) range are currently the only means to measure magnetic fields in the upper chromosphere and transition region of the solar atmosphere. The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) aims to measure linear polarization at the hydrogen Lyman- α line (121.6 nm). This measurement requires a polarization sensitivity better than 0.1 %, which is unprecedented in the VUV range. We here present a strategy with which to realize such high-precision spectro-polarimetry. This involves the optimization of instrument design, testing of optical components, extensive analyses of polarization errors, polarization calibration of the instrument, and calibration with onboard data. We expect that this strategy will aid the development of other advanced high-precision polarimeters in the UV as well as in other wavelength ranges.

  3. Application of a microplate-based ORAC-pyrogallol red assay for the estimation ofantioxidant capacity: First Action 2012.03.

    PubMed

    Ortiz, Rocío; Antilén, Mónica; Speisky, Hernán; Aliaga, Margarita E; López-Alarcón, Camilo; Baugh, Steve

    2012-01-01

    A method was developed for microplate-based oxygen radicals absorbance capacity (ORAC) using pyrogallol red (PGR) as probe (ORAC-PGR). The method was evaluated for linearity, precision, and accuracy. In addition, the antioxidant capacity of commercial beverages, such as wines, fruit juices, and iced teas, was measured. Linearity of the area under the curve (AUC) versus Trolox concentration plots was [AUC = (845 +/- 110) + (23 +/- 2) [Trolox, microM]; R = 0.9961, n = 19]. Analyses showed better precision and accuracy at the highest Trolox concentration (40 microM) with RSD and recovery (REC) values of 1.7 and 101.0%, respectively. The method also showed good linearity for red wine [AUC = (787 +/- 77) + (690 +/- 60) [red wine, microL/mL]; R = 0.9926, n = 17], precision and accuracy with RSD values from 1.4 to 8.3%, and REC values that ranged from 89.7 to 103.8%. Red wines showed higher ORAC-PGR values than white wines, while the ORAC-PGR index of fruit juices and iced teas presented a wide range of results, from 0.6 to 21.6 mM of Trolox equivalents. Product-to-product variability was also observed for juices of the same fruit, showing the differences between brands on the ORAC-PGR index.

  4. Determination of some phenolic compounds in red wine by RP-HPLC: method development and validation.

    PubMed

    Burin, Vívian Maria; Arcari, Stefany Grützmann; Costa, Léa Luzia Freitas; Bordignon-Luiz, Marilde T

    2011-09-01

    A methodology employing reversed-phase high-performance liquid chromatography (RP-HPLC) was developed and validated for simultaneous determination of five phenolic compounds in red wine. The chromatographic separation was carried out in a C(18) column with water acidify with acetic acid (pH 2.6) (solvent A) and 20% solvent A and 80% acetonitrile (solvent B) as the mobile phase. The validation parameters included: selectivity, linearity, range, limits of detection and quantitation, precision and accuracy, using an internal standard. All calibration curves were linear (R(2) > 0.999) within the range, and good precision (RSD < 2.6%) and recovery (80-120%) was obtained for all compounds. This method was applied to quantify phenolics in red wine samples from Santa Catarina State, Brazil, and good separation peaks for phenolic compounds in these wines were observed.

  5. High Precision Piezoelectric Linear Motors for Operations at Cryogenic Temperatures and Vacuum

    NASA Technical Reports Server (NTRS)

    Wong, D.; Carman, G.; Stam, M.; Bar-Cohen, Y.; Sen, A.; Henry, P.; Bearman, G.; Moacanin, J.

    1995-01-01

    The use of an electromechanical device for optically positioning a mirror system during the pre-project phase of the Pluto Fast Flyby mission was evaluated at JPL. The device under consideration was a piezoelectric driven linear motor functionally dependent upon a time varying electric field which induces displacements ranging from submicrons to millimeters with positioning accuracy within nanometers.

  6. On the Linear Relation between the Mean and the Standard Deviation of a Response Time Distribution

    ERIC Educational Resources Information Center

    Wagenmakers, Eric-Jan; Brown, Scott

    2007-01-01

    Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different…

  7. Reversed phase HPLC for strontium ranelate: Method development and validation applying experimental design.

    PubMed

    Kovács, Béla; Kántor, Lajos Kristóf; Croitoru, Mircea Dumitru; Kelemen, Éva Katalin; Obreja, Mona; Nagy, Előd Ernő; Székely-Szentmiklósi, Blanka; Gyéresi, Árpád

    2018-06-01

    A reverse-phase HPLC (RP-HPLC) method was developed for strontium ranelate using a full factorial, screening experimental design. The analytical procedure was validated according to international guidelines for linearity, selectivity, sensitivity, accuracy and precision. A separate experimental design was used to demonstrate the robustness of the method. Strontium ranelate was eluted at 4.4 minutes and showed no interference with the excipients used in the formulation, at 321 nm. The method is linear in the range of 20-320 μg mL-1 (R2 = 0.99998). Recovery, tested in the range of 40-120 μg mL-1, was found to be 96.1-102.1 %. Intra-day and intermediate precision RSDs ranged from 1.0-1.4 and 1.2-1.4 %, resp. The limit of detection and limit of quantitation were 0.06 and 0.20 μg mL-1, resp. The proposed technique is fast, cost-effective, reliable and reproducible, and is proposed for the routine analysis of strontium ranelate.

  8. Accuracy of the Precision® point-of-care ketone test examined by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in the same fingerstick sample.

    PubMed

    Janssen, Marcel J W; Hendrickx, Ben H E; Habets-van der Poel, Carin D; van den Bergh, Joop P W; Haagen, Anton A M; Bakker, Jaap A

    2010-12-01

    The Precision(®) (Abbott Diabetes Care) point-of-care biosensor test strips are widely used by patients with diabetes and clinical laboratories for measurement of plasma β-hydroxybutyrate (β-HB) concentrations in capillary blood samples obtained by fingerstick. In the literature, this procedure has been validated only against the enzymatic determination of β-HB in venous plasma, i.e., the method to which the Precision(®) has been calibrated. In this study, the Precision(®) Xceed was compared to a methodologically different and superior procedure: determination of β-HB by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in capillary blood spots. Blood spots were obtained from the same fingerstick sample from out of which Precision(®) measurements were performed. Linearity was tested by adding varying amounts of standard to an EDTA venous whole blood matrix. The Precision(®) was in good agreement with LC-MS/MS within the measuring range of 0.0-6.0 mmol/L (Passing and Bablok regression: slope=1.20 and no significant intercept, R=0.97, n=59). Surprisingly, the Precision(®) showed non-linearity and full saturation at concentrations above 6.0 mmol/L, which were confirmed by a standard addition experiment. Results obtained at the saturation level varied between 3.0 and 6.5 mmol/L. The Precision(®) β-HB test strips demonstrate good comparison with LC-MS/MS. Inter-individual variation around the saturation level, however, is large. Therefore, we advise reporting readings above 3.0 as >3.0 mmol/L. The test is valid for use in the clinically relevant range of 0.0-3.0 mmol/L.

  9. Clinical evaluation of the Technico Stat/Ion system.

    PubMed

    Slaunwhite, D; Clements, J C; Reynoso, G

    1977-02-01

    1. We describe our evaluation of the Technicon Stat/Ion, an instrument which performs sodium, chloride and bicarbonate analysis simultaneously. 2. All four of the assays resulted in linear response over the entire clinical range with insignificant carryover between specimens. 3. Precision studies for within-run variation were: sodium 0.3 percent, potassium 0.7 percent, chloride 0.5 percent and bicarbonate 1.6 percent. Day-to-day precision was similar to the within-run precision. 4. Comparison methods for sodium, potassium, chloride and bicarbonate utilizing flame photometry, chloridometry and titration of released carbon dioxide respectively showed the following linear regression and correlation coefficients: sodium y=0.96+5.5 (a=0.988) potassium y=1.01x+0.0 (a=.996) chloride y=0.99x+1.0 (a=.993)bicarbonate y=1.0x+1.2 (alpha=.969).

  10. Development and application of a validated HPLC method for the analysis of dissolution samples of levothyroxine sodium drug products.

    PubMed

    Collier, J W; Shah, R B; Bryant, A R; Habib, M J; Khan, M A; Faustino, P J

    2011-02-20

    A rapid, selective, and sensitive gradient HPLC method was developed for the analysis of dissolution samples of levothyroxine sodium tablets. Current USP methodology for levothyroxine (L-T(4)) was not adequate to resolve co-elutants from a variety of levothyroxine drug product formulations. The USP method for analyzing dissolution samples of the drug product has shown significant intra- and inter-day variability. The sources of method variability include chromatographic interferences introduced by the dissolution media and the formulation excipients. In the present work, chromatographic separation of levothyroxine was achieved on an Agilent 1100 Series HPLC with a Waters Nova-pak column (250 mm × 3.9 mm) using a 0.01 M phosphate buffer (pH 3.0)-methanol (55:45, v/v) in a gradient elution mobile phase at a flow rate of 1.0 mL/min and detection UV wavelength of 225 nm. The injection volume was 800 μL and the column temperature was maintained at 28°C. The method was validated according to USP Category I requirements. The validation characteristics included accuracy, precision, specificity, linearity, and analytical range. The standard curve was found to have a linear relationship (r(2)>0.99) over the analytical range of 0.08-0.8 μg/mL. Accuracy ranged from 90 to 110% for low quality control (QC) standards and 95 to 105% for medium and high QC standards. Precision was <2% at all QC levels. The method was found to be accurate, precise, selective, and linear for L-T(4) over the analytical range. The HPLC method was successfully applied to the analysis of dissolution samples of marketed levothyroxine sodium tablets. Published by Elsevier B.V.

  11. Development and application of a validated HPLC method for the analysis of dissolution samples of levothyroxine sodium drug products

    PubMed Central

    Collier, J.W.; Shah, R.B.; Bryant, A.R.; Habib, M.J.; Khan, M.A.; Faustino, P.J.

    2011-01-01

    A rapid, selective, and sensitive gradient HPLC method was developed for the analysis of dissolution samples of levothyroxine sodium tablets. Current USP methodology for levothyroxine (l-T4) was not adequate to resolve co-elutants from a variety of levothyroxine drug product formulations. The USP method for analyzing dissolution samples of the drug product has shown significant intra- and inter-day variability. The sources of method variability include chromatographic interferences introduced by the dissolution media and the formulation excipients. In the present work, chromatographic separation of levothyroxine was achieved on an Agilent 1100 Series HPLC with a Waters Nova-pak column (250mm × 3.9mm) using a 0.01 M phosphate buffer (pH 3.0)–methanol (55:45, v/v) in a gradient elution mobile phase at a flow rate of 1.0 mL/min and detection UV wavelength of 225 nm. The injection volume was 800 µL and the column temperature was maintained at 28 °C. The method was validated according to USP Category I requirements. The validation characteristics included accuracy, precision, specificity, linearity, and analytical range. The standard curve was found to have a linear relationship (r2 > 0.99) over the analytical range of 0.08–0.8 µg/mL. Accuracy ranged from 90 to 110% for low quality control (QC) standards and 95 to 105% for medium and high QC standards. Precision was <2% at all QC levels. The method was found to be accurate, precise, selective, and linear for l-T4 over the analytical range. The HPLC method was successfully applied to the analysis of dissolution samples of marketed levothyroxine sodium tablets. PMID:20947276

  12. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique.

    PubMed

    Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan; Kim, Hae-Young

    2014-03-01

    This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.

  13. Validation of analytical methods in GMP: the disposable Fast Read 102® device, an alternative practical approach for cell counting.

    PubMed

    Gunetti, Monica; Castiglia, Sara; Rustichelli, Deborah; Mareschi, Katia; Sanavio, Fiorella; Muraro, Michela; Signorino, Elena; Castello, Laura; Ferrero, Ivana; Fagioli, Franca

    2012-05-31

    The quality and safety of advanced therapy products must be maintained throughout their production and quality control cycle to ensure their final use in patients. We validated the cell count method according to the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use and European Pharmacopoeia, considering the tests' accuracy, precision, repeatability, linearity and range. As the cell count is a potency test, we checked accuracy, precision, and linearity, according to ICH Q2. Briefly our experimental approach was first to evaluate the accuracy of Fast Read 102® compared to the Bürker chamber. Once the accuracy of the alternative method was demonstrated, we checked the precision and linearity test only using Fast Read 102®. The data were statistically analyzed by average, standard deviation and coefficient of variation percentages inter and intra operator. All the tests performed met the established acceptance criteria of a coefficient of variation of less than ten percent. For the cell count, the precision reached by each operator had a coefficient of variation of less than ten percent (total cells) and under five percent (viable cells). The best range of dilution, to obtain a slope line value very similar to 1, was between 1:8 and 1:128. Our data demonstrated that the Fast Read 102® count method is accurate, precise and ensures the linearity of the results obtained in a range of cell dilution. Under our standard method procedures, this assay may thus be considered a good quality control method for the cell count as a batch release quality control test. Moreover, the Fast Read 102® chamber is a plastic, disposable device that allows a number of samples to be counted in the same chamber. Last but not least, it overcomes the problem of chamber washing after use and so allows a cell count in a clean environment such as that in a Cell Factory. In a good manufacturing practice setting the disposable cell counting devices will allow a single use of the count chamber they can then be thrown away, thus avoiding the waste disposal of vital dye (e.g. Trypan Blue) or lysing solution (e.g. Tuerk solution).

  14. Validation of analytical methods in GMP: the disposable Fast Read 102® device, an alternative practical approach for cell counting

    PubMed Central

    2012-01-01

    Background The quality and safety of advanced therapy products must be maintained throughout their production and quality control cycle to ensure their final use in patients. We validated the cell count method according to the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use and European Pharmacopoeia, considering the tests’ accuracy, precision, repeatability, linearity and range. Methods As the cell count is a potency test, we checked accuracy, precision, and linearity, according to ICH Q2. Briefly our experimental approach was first to evaluate the accuracy of Fast Read 102® compared to the Bürker chamber. Once the accuracy of the alternative method was demonstrated, we checked the precision and linearity test only using Fast Read 102®. The data were statistically analyzed by average, standard deviation and coefficient of variation percentages inter and intra operator. Results All the tests performed met the established acceptance criteria of a coefficient of variation of less than ten percent. For the cell count, the precision reached by each operator had a coefficient of variation of less than ten percent (total cells) and under five percent (viable cells). The best range of dilution, to obtain a slope line value very similar to 1, was between 1:8 and 1:128. Conclusions Our data demonstrated that the Fast Read 102® count method is accurate, precise and ensures the linearity of the results obtained in a range of cell dilution. Under our standard method procedures, this assay may thus be considered a good quality control method for the cell count as a batch release quality control test. Moreover, the Fast Read 102® chamber is a plastic, disposable device that allows a number of samples to be counted in the same chamber. Last but not least, it overcomes the problem of chamber washing after use and so allows a cell count in a clean environment such as that in a Cell Factory. In a good manufacturing practice setting the disposable cell counting devices will allow a single use of the count chamber they can then be thrown away, thus avoiding the waste disposal of vital dye (e.g. Trypan Blue) or lysing solution (e.g. Tuerk solution). PMID:22650233

  15. A validated ultra high-pressure liquid chromatography method for separation of candesartan cilexetil impurities and its degradents in drug product

    PubMed Central

    Kumar, Namala Durga Atchuta; Babu, K. Sudhakar; Gosada, Ullas; Sharma, Nitish

    2012-01-01

    Introduction: A selective, specific, and sensitive “Ultra High-Pressure Liquid Chromatography” (UPLC) method was developed for determination of candesartan cilexetil impurities as well asits degradent in tablet formulation. Materials and Methods: The chromatographic separation was performed on Waters Acquity UPLC system and BEH Shield RP18 column using gradient elution of mobile phase A and B. 0.01 M phosphate buffer adjusted pH 3.0 with Orthophosphoric acid was used as mobile phase A and 95% acetonitrile with 5% Milli Q Water was used as mobile phase B. Ultraviolet (UV) detection was performed at 254 nm and 210 nm, where (CDS-6), (CDS-5), (CDS-7), (Ethyl Candesartan), (Desethyl CCX), (N-Ethyl), (CCX-1), (1 N Ethyl Oxo CCX), (2 N Ethyl Oxo CCX), (2 N Ethyl) and any unknown impurity were monitored at 254 nm wavelength, and two process-related impurities, trityl alcohol and MTE impurity, were estimated at 210 nm. Candesartan cilexetil andimpurities were chromatographed with a total run time of 20 min. Results: Calibration showed that the response of impurity was a linear function of concentration over the range limit of quantification to 2 μg/mL (r2≥0.999) and the method was validated over this range for precision, intermediate precision, accuracy, linearity, and specificity. For the precision study, percentage relative standard deviation of each impurity was <15% (n=6). Conclusion: The method was found to be precise, accurate, linear, and specific. The proposed method was successfully employed for estimation of candesartan cilexetil impurities in pharmaceutical preparations. PMID:23781475

  16. Improved quality control of [18F]fluoromethylcholine.

    PubMed

    Nader, Michael; Reindl, Dietmar; Eichinger, Reinhard; Beheshti, Mohsen; Langsteger, Werner

    2011-11-01

    With respect to the broad application of [(18)F-methyl]fluorocholine (FCH), there is a need for a safe, but also efficient and convenient way for routine quality control of FCH. Therefore, a GC- method should be developed and validated which allows the simultaneous quantitation of all chemical impurities and residual solvents such as acetonitrile, ethanol, dibromomethane and N,N-dimethylaminoethanol. Analytical GC has been performed with a GC-capillary column Optima 1701 (50 m×0.32 mm), and a pre-column deactivated capillary column phenyl-Sil (10 m×0.32) in line with a flame ionization detector (FID) was used. The validation includes the following tests: specificity, range, accuracy, linearity, precision, limit of detection (LOD) and limit of quantitation (LOQ) of all listed substances. The described GC method has been successfully used for the quantitation of the listed chemical impurities. The specificity of the GC separation has been proven by demonstrating that the appearing peaks are completely separated from each other and that a resolution R≥1.5 for the separation of the peaks could be achieved. The specified range confirmed that the analytical procedure provides an acceptable degree of linearity, accuracy and precision. For each substance, a range from 2% to 120% of the specification limit could be demonstrated. The corresponding LOD values were determined and were much lower than the specification limits. An efficient and convenient GC method for the quality control of FCH has been developed and validated which meets all acceptance criteria in terms of linearity, specificity, precision, accuracy, LOD and LOQ. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Influence of non-ideal performance of lasers on displacement precision in single-grating heterodyne interferometry

    NASA Astrophysics Data System (ADS)

    Wang, Guochao; Xie, Xuedong; Yan, Shuhua

    2010-10-01

    Principle of the dual-wavelength single grating nanometer displacement measuring system, with a long range, high precision, and good stability, is presented. As a result of the nano-level high-precision displacement measurement, the error caused by a variety of adverse factors must be taken into account. In this paper, errors, due to the non-ideal performance of the dual-frequency laser, including linear error caused by wavelength instability and non-linear error caused by elliptic polarization of the laser, are mainly discussed and analyzed. On the basis of theoretical modeling, the corresponding error formulas are derived as well. Through simulation, the limit value of linear error caused by wavelength instability is 2nm, and on the assumption that 0.85 x T = , 1 Ty = of the polarizing beam splitter(PBS), the limit values of nonlinear-error caused by elliptic polarization are 1.49nm, 2.99nm, 4.49nm while the non-orthogonal angle is selected correspondingly at 1°, 2°, 3° respectively. The law of the error change is analyzed based on different values of Tx and Ty .

  18. Anodic Oxidation of Etodolac and its Linear Sweep, Square Wave and Differential Pulse Voltammetric Determination in Pharmaceuticals

    PubMed Central

    Yilmaz, B.; Kaban, S.; Akcay, B. K.

    2015-01-01

    In this study, simple, fast and reliable cyclic voltammetry, linear sweep voltammetry, square wave voltammetry and differential pulse voltammetry methods were developed and validated for determination of etodolac in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of etodolac at platinum electrode in acetonitrile solution containing 0.1 M lithium perchlorate. The well-defined oxidation peak was observed at 1.03 V. The calibration curves were linear for etodolac at the concentration range of 2.5-50 μg/ml for linear sweep, square wave and differential pulse voltammetry methods, respectively. Intra- and inter-day precision values for etodolac were less than 4.69, and accuracy (relative error) was better than 2.00%. The mean recovery of etodolac was 100.6% for pharmaceutical preparations. No interference was found from three tablet excipients at the selected assay conditions. Developed methods in this study are accurate, precise and can be easily applied to Etol, Tadolak and Etodin tablets as pharmaceutical preparation. PMID:26664057

  19. Development and validation of dissolution study of sustained release dextromethorphan hydrobromide tablets.

    PubMed

    Rajan, Sekar; Colaco, Socorrina; Ramesh, N; Meyyanathan, Subramania Nainar; Elango, K

    2014-02-01

    This study describes the development and validation of dissolution tests for sustained release Dextromethorphan hydrobromide tablets using an HPLC method. Chromatographic separation was achieved on a C18 column utilizing 0.5% triethylamine (pH 7.5) and acetonitrile in the ratio of 50:50. The detection wavelength was 280 nm. The method was validated and response was found to be linear in the drug concentration range of 10-80 microg mL(-1). The suitable conditions were clearly decided after testing sink conditions, dissolution medium and agitation intensity. The most excellent dissolution conditions tested, for the Dextromethorphan hydrobromide was applied to appraise the dissolution profiles. The method was validated and response was found to be linear in the drug concentration range of 10-80 microg mL(-1). The method was established to have sufficient intermediate precision as similar separation was achieved on another instrument handled by different operators. Mean Recovery was 101.82%. Intra precisions for three different concentrations were 1.23, 1.10 0.72 and 1.57, 1.69, 0.95 and inter run precisions were % RSD 0.83, 1.36 and 1.57%, respectively. The method was successfully applied for dissolution study of the developed Dextromethorphan hydrobromide tablets.

  20. Simultaneous Determination of Ofloxacin and Flavoxate Hydrochloride by Absorption Ratio and Second Derivative UV Spectrophotometry

    PubMed Central

    Attimarad, Mahesh

    2010-01-01

    The objective of this study was to develop simple, precise, accurate and sensitive UV spectrophotometric methods for the simultaneous determination of ofloxacin (OFX) and flavoxate HCl (FLX) in pharmaceutical formulations. The first method is based on absorption ratio method, by formation of Q absorbance equation at 289 nm (λmax of OFX) and 322.4 nm (isoabsorptive point). The linearity range was found to be 1 to 30 μg/ml for FLX and OFX. In the method-II second derivative absorption at 311.4 nm for OFX (zero crossing for FLX) and at 246.2 nm for FLX (zero crossing for OFX) was used for the determination of the drugs and the linearity range was found to be 2 to 30 μg/ml for OFX and 2-75 μg /ml for FLX. The accuracy and precision of the methods were determined and validated statistically. Both the methods showed good reproducibility and recovery with % RSD less than 1.5%. Both the methods were found to be rapid, specific, precise and accurate and can be successfully applied for the routine analysis of OFX and FLX in combined dosage form PMID:24826003

  1. Validating data analysis of broadband laser ranging

    NASA Astrophysics Data System (ADS)

    Rhodes, M.; Catenacci, J.; Howard, M.; La Lone, B.; Kostinski, N.; Perry, D.; Bennett, C.; Patterson, J.

    2018-03-01

    Broadband laser ranging combines spectral interferometry and a dispersive Fourier transform to achieve high-repetition-rate measurements of the position of a moving surface. Telecommunications fiber is a convenient tool for generating the large linear dispersions required for a dispersive Fourier transform, but standard fiber also has higher-order dispersion that distorts the Fourier transform. Imperfections in the dispersive Fourier transform significantly complicate the ranging signal and must be dealt with to make high-precision measurements. We describe in detail an analysis process for interpreting ranging data when standard telecommunications fiber is used to perform an imperfect dispersive Fourier transform. This analysis process is experimentally validated over a 27-cm scan of static positions, showing an accuracy of 50 μm and a root-mean-square precision of 4.7 μm.

  2. Analog-to-digital conversion techniques for precision photometry

    NASA Technical Reports Server (NTRS)

    Opal, Chet B.

    1988-01-01

    Three types of analog-to-digital converters are described: parallel, successive-approximation, and integrating. The functioning of comparators and sample-and-hold amplifiers is explained. Differential and integral linearity are defined, and good and bad examples are illustrated. The applicability and relative advantages of the three types of converters for precision astronomical photometric measurements are discussed. For most measurements, integral linearity is more important than differential linearity. Successive-approximation converters should be used with multielement solid state detectors because of their high speed, but dual slope integrating converters may be superior for use with single element solid state detectors where speed of digitization is not a factor. In all cases, the input signal should be tailored so that they occupy the upper part of the converter's dynamic range; this can be achieved by providing adjustable gain, or better by varying the integration time of the observation if possible.

  3. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

    PubMed Central

    Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan

    2014-01-01

    Objective This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. Results The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. Conclusions The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models. PMID:24696823

  4. A Miniaturized Colorimeter with a Novel Design and High Precision for Photometric Detection.

    PubMed

    Yan, Jun-Chao; Chen, Yan; Pang, Yu; Slavik, Jan; Zhao, Yun-Fei; Wu, Xiao-Ming; Yang, Yi; Yang, Si-Fan; Ren, Tian-Ling

    2018-03-08

    Water quality detection plays an increasingly important role in environmental protection. In this work, a novel colorimeter based on the Beer-Lambert law was designed for chemical element detection in water with high precision and miniaturized structure. As an example, the colorimeter can detect phosphorus, which was accomplished in this article to evaluate the performance. Simultaneously, a modified algorithm was applied to extend the linear measurable range. The colorimeter encompassed a near infrared laser source, a microflow cell based on microfluidic technology and a light-sensitive detector, then Micro-Electro-Mechanical System (MEMS) processing technology was used to form a stable integrated structure. Experiments were performed based on the ammonium molybdate spectrophotometric method, including the preparation of phosphorus standard solution, reducing agent, chromogenic agent and color reaction. The device can obtain a wide linear response range (0.05 mg/L up to 7.60 mg/L), a wide reliable measuring range up to 10.16 mg/L after using a novel algorithm, and a low limit of detection (0.02 mg/L). The size of flow cell in this design is 18 mm × 2.0 mm × 800 μm, obtaining a low reagent consumption of 0.004 mg ascorbic acid and 0.011 mg ammonium molybdate per determination. Achieving these advantages of miniaturized volume, high precision and low cost, the design can also be used in automated in situ detection.

  5. A Miniaturized Colorimeter with a Novel Design and High Precision for Photometric Detection

    PubMed Central

    Chen, Yan; Pang, Yu; Slavik, Jan; Zhao, Yun-Fei; Wu, Xiao-Ming; Yang, Yi; Yang, Si-Fan; Ren, Tian-Ling

    2018-01-01

    Water quality detection plays an increasingly important role in environmental protection. In this work, a novel colorimeter based on the Beer-Lambert law was designed for chemical element detection in water with high precision and miniaturized structure. As an example, the colorimeter can detect phosphorus, which was accomplished in this article to evaluate the performance. Simultaneously, a modified algorithm was applied to extend the linear measurable range. The colorimeter encompassed a near infrared laser source, a microflow cell based on microfluidic technology and a light-sensitive detector, then Micro-Electro-Mechanical System (MEMS) processing technology was used to form a stable integrated structure. Experiments were performed based on the ammonium molybdate spectrophotometric method, including the preparation of phosphorus standard solution, reducing agent, chromogenic agent and color reaction. The device can obtain a wide linear response range (0.05 mg/L up to 7.60 mg/L), a wide reliable measuring range up to 10.16 mg/L after using a novel algorithm, and a low limit of detection (0.02 mg/L). The size of flow cell in this design is 18 mm × 2.0 mm × 800 μm, obtaining a low reagent consumption of 0.004 mg ascorbic acid and 0.011 mg ammonium molybdate per determination. Achieving these advantages of miniaturized volume, high precision and low cost, the design can also be used in automated in situ detection. PMID:29518059

  6. Bit Grooming: statistically accurate precision-preserving quantization with compression, evaluated in the netCDF Operators (NCO, v4.4.8+)

    NASA Astrophysics Data System (ADS)

    Zender, Charles S.

    2016-09-01

    Geoscientific models and measurements generate false precision (scientifically meaningless data bits) that wastes storage space. False precision can mislead (by implying noise is signal) and be scientifically pointless, especially for measurements. By contrast, lossy compression can be both economical (save space) and heuristic (clarify data limitations) without compromising the scientific integrity of data. Data quantization can thus be appropriate regardless of whether space limitations are a concern. We introduce, implement, and characterize a new lossy compression scheme suitable for IEEE floating-point data. Our new Bit Grooming algorithm alternately shaves (to zero) and sets (to one) the least significant bits of consecutive values to preserve a desired precision. This is a symmetric, two-sided variant of an algorithm sometimes called Bit Shaving that quantizes values solely by zeroing bits. Our variation eliminates the artificial low bias produced by always zeroing bits, and makes Bit Grooming more suitable for arrays and multi-dimensional fields whose mean statistics are important. Bit Grooming relies on standard lossless compression to achieve the actual reduction in storage space, so we tested Bit Grooming by applying the DEFLATE compression algorithm to bit-groomed and full-precision climate data stored in netCDF3, netCDF4, HDF4, and HDF5 formats. Bit Grooming reduces the storage space required by initially uncompressed and compressed climate data by 25-80 and 5-65 %, respectively, for single-precision values (the most common case for climate data) quantized to retain 1-5 decimal digits of precision. The potential reduction is greater for double-precision datasets. When used aggressively (i.e., preserving only 1-2 digits), Bit Grooming produces storage reductions comparable to other quantization techniques such as Linear Packing. Unlike Linear Packing, whose guaranteed precision rapidly degrades within the relatively narrow dynamic range of values that it can compress, Bit Grooming guarantees the specified precision throughout the full floating-point range. Data quantization by Bit Grooming is irreversible (i.e., lossy) yet transparent, meaning that no extra processing is required by data users/readers. Hence Bit Grooming can easily reduce data storage volume without sacrificing scientific precision or imposing extra burdens on users.

  7. Analytical parameters of the microplate-based ORAC-pyrogallol red assay.

    PubMed

    Ortiz, Rocío; Antilén, Mónica; Speisky, Hernán; Aliaga, Margarita E; López-Alarcón, Camilo

    2011-01-01

    The analytical parameters of the microplate-based oxygen radicals absorbance capacity (ORAC) method using pyrogallol red (PGR) as probe (ORAC-PGR) are presented. In addition, the antioxidant capacity of commercial beverages, such as wines, fruit juices, and iced teas, is estimated. A good linearity of the area under the curve (AUC) versus Trolox concentration plots was obtained [AUC = (845 +/- 110) + (23 +/- 2) [Trolox, microM], R = 0.9961, n = 19]. QC experiments showed better precision and accuracy at the highest Trolox concentration (40 microM) with RSD and REC (recuperation) values of 1.7 and 101.0%, respectively. When red wine was used as sample, the method also showed good linearity [AUC = (787 +/- 77) + (690 +/- 60) [red wine, microL/mL]; R = 0.9926, n = 17], precision and accuracy with RSD values from 1.4 to 8.3%, and REC values that ranged from 89.7 to 103.8%. Additivity assays using solutions containing gallic acid and Trolox (or red wine) showed an additive protection of PGR given by the samples. Red wines showed higher ORAC-PGR values than white wines, while the ORAC-PGR index of fruit juices and iced teas presented a great variability, ranging from 0.6 to 21.6 mM of Trolox equivalents. This variability was also observed for juices of the same fruit, showing the influence of the brand on the ORAC-PGR index. The ORAC-PGR methodology can be applied in a microplate reader with good linearity, precision, and accuracy.

  8. Evaluation of Piecewise Polynomial Equations for Two Types of Thermocouples

    PubMed Central

    Chen, Andrew; Chen, Chiachung

    2013-01-01

    Thermocouples are the most frequently used sensors for temperature measurement because of their wide applicability, long-term stability and high reliability. However, one of the major utilization problems is the linearization of the transfer relation between temperature and output voltage of thermocouples. The linear calibration equation and its modules could be improved by using regression analysis to help solve this problem. In this study, two types of thermocouple and five temperature ranges were selected to evaluate the fitting agreement of different-order polynomial equations. Two quantitative criteria, the average of the absolute error values |e|ave and the standard deviation of calibration equation estd, were used to evaluate the accuracy and precision of these calibrations equations. The optimal order of polynomial equations differed with the temperature range. The accuracy and precision of the calibration equation could be improved significantly with an adequate higher degree polynomial equation. The technique could be applied with hardware modules to serve as an intelligent sensor for temperature measurement. PMID:24351627

  9. Rapid method for the determination of 14 isoflavones in food using UHPLC coupled to photo diode array detection.

    PubMed

    Shim, You-Shin; Yoon, Won-Jin; Hwang, Jin-Bong; Park, Hyun-Jin; Seo, Dongwon; Ha, Jaeho

    2015-11-15

    A rapid method for the determination of 14 types of isoflavones in food using ultra-high performance liquid chromatography (UHPLC) was validated in terms of precision, accuracy, sensitivity and linearity. The UHPLC separation was performed on a reverse-phase C18 column (particle size 2 μm, i.d. 2 mm, length 100 mm) using a photo diode array detector that was fixed to 260 nm. The limits of detection and quantification of the UHPLC analyses ranged from 0.03 to 0.33 mg kg(-1). The intra-day and inter-day precision of the individual isoflavones were less than 11.77% and calibration curves exhibited good linearity (r(2) = 0.99) within the tested ranges. These results suggest that the rapid method used in this study could be available to determine of 14 types of isoflavones in a variety of food such as soy bean, black bean, red bean and soybean paste. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. A creatinine biosensor based on admittance measurement

    NASA Astrophysics Data System (ADS)

    Ching, Congo Tak-Shing; Sun, Tai-Ping; Jheng, Deng-Yun; Tsai, Hou-Wei; Shieh, Hsiu-Li

    2015-08-01

    Regular check of blood creatinine level is very important as it is a measurement of renal function. Therefore, the objective of this study is to develop a simple and reliable creatinine biosensor based on admittance measurement for precise determination of creatinine. The creatinine biosensor was fabricated with creatinine deiminase immobilized on screen-printed carbon electrodes. Admittance measurement at a specific frequency ranges (22.80 - 84.71 Hz) showed that the biosensor has an excellent linear (r2 > 0.95) response range (50 - 250 uM), which covers the normal physiological and pathological ranges of blood creatinine levels. Intraclass correlation coefficient (ICC) showed that the biosensor has excellent reliability and validity (ICC = 0.98). In conclusion, a simple and reliable creatinine biosensor was developed and it is capable of precisely determining blood creatinine levels in both the normal physiological and pathological ranges.

  11. A survey of the state of the art and focused research in range systems, task 2

    NASA Technical Reports Server (NTRS)

    Yao, K.

    1986-01-01

    Many communication, control, and information processing subsystems are modeled by linear systems incorporating tapped delay lines (TDL). Such optimized subsystems result in full precision multiplications in the TDL. In order to reduce complexity and cost in a microprocessor implementation, these multiplications can be replaced by single-shift instructions which are equivalent to powers of two multiplications. Since, in general, the obvious operation of rounding the infinite precision TDL coefficients to the nearest powers of two usually yield quite poor system performance, the optimum powers of two coefficient solution was considered. Detailed explanations on the use of branch-and-bound algorithms for finding the optimum powers of two solutions are given. Specific demonstration of this methodology to the design of a linear data equalizer and its implementation in assembly language on a 8080 microprocessor with a 12 bit A/D converter are reported. This simple microprocessor implementation with optimized TDL coefficients achieves a system performance comparable to the optimum linear equalization with full precision multiplications for an input data rate of 300 baud. The philosophy demonstrated in this implementation is dully applicable to many other microprocessor controlled information processing systems.

  12. Comparisons between designs for single-sided linear electric motors: Homopolar synchronous and induction

    NASA Astrophysics Data System (ADS)

    Nondahl, T. A.; Richter, E.

    1980-09-01

    A design study of two types of single sided (with a passive rail) linear electric machine designs, namely homopolar linear synchronous machines (LSM's) and linear induction machines (LIM's), is described. It is assumed the machines provide tractive effort for several types of light rail vehicles and locomotives. These vehicles are wheel supported and require tractive powers ranging from 200 kW to 3735 kW and top speeds ranging from 112 km/hr to 400 km/hr. All designs are made according to specified magnetic and thermal criteria. The LSM advantages are a higher power factor, much greater restoring forces for track misalignments, and less track heating. The LIM advantages are no need to synchronize the excitation frequency precisely to vehicle speed, simpler machine construction, and a more easily anchored track structure. The relative weights of the two machine types vary with excitation frequency and speed; low frequencies and low speeds favor the LSM.

  13. Probing New Long-Range Interactions by Isotope Shift Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berengut, Julian C.; Budker, Dmitry; Delaunay, Cédric

    We explore a method to probe new long- and intermediate-range interactions using precision atomic isotope shift spectroscopy. We develop a formalism to interpret linear King plots as bounds on new physics with minimal theory inputs. We focus only on bounding the new physics contributions that can be calculated independently of the standard model nuclear effects. We apply our method to existing Ca + data and project its sensitivity to conjectured new bosons with spin-independent couplings to the electron and the neutron using narrow transitions in other atoms and ions, specifically, Sr and Yb. Future measurements are expected to improve themore » relative precision by 5 orders of magnitude, and they can potentially lead to an unprecedented sensitivity for bosons within the 0.3 to 10 MeV mass range.« less

  14. Probing New Long-Range Interactions by Isotope Shift Spectroscopy.

    PubMed

    Berengut, Julian C; Budker, Dmitry; Delaunay, Cédric; Flambaum, Victor V; Frugiuele, Claudia; Fuchs, Elina; Grojean, Christophe; Harnik, Roni; Ozeri, Roee; Perez, Gilad; Soreq, Yotam

    2018-03-02

    We explore a method to probe new long- and intermediate-range interactions using precision atomic isotope shift spectroscopy. We develop a formalism to interpret linear King plots as bounds on new physics with minimal theory inputs. We focus only on bounding the new physics contributions that can be calculated independently of the standard model nuclear effects. We apply our method to existing Ca^{+} data and project its sensitivity to conjectured new bosons with spin-independent couplings to the electron and the neutron using narrow transitions in other atoms and ions, specifically, Sr and Yb. Future measurements are expected to improve the relative precision by 5 orders of magnitude, and they can potentially lead to an unprecedented sensitivity for bosons within the 0.3 to 10 MeV mass range.

  15. Probing New Long-Range Interactions by Isotope Shift Spectroscopy

    DOE PAGES

    Berengut, Julian C.; Budker, Dmitry; Delaunay, Cédric; ...

    2018-02-26

    We explore a method to probe new long- and intermediate-range interactions using precision atomic isotope shift spectroscopy. We develop a formalism to interpret linear King plots as bounds on new physics with minimal theory inputs. We focus only on bounding the new physics contributions that can be calculated independently of the standard model nuclear effects. We apply our method to existing Ca + data and project its sensitivity to conjectured new bosons with spin-independent couplings to the electron and the neutron using narrow transitions in other atoms and ions, specifically, Sr and Yb. Future measurements are expected to improve themore » relative precision by 5 orders of magnitude, and they can potentially lead to an unprecedented sensitivity for bosons within the 0.3 to 10 MeV mass range.« less

  16. Development of an ultrasonic linear motor with ultra-positioning capability and four driving feet.

    PubMed

    Zhu, Cong; Chu, Xiangcheng; Yuan, Songmei; Zhong, Zuojin; Zhao, Yanqiang; Gao, Shuning

    2016-12-01

    This paper presents a novel linear piezoelectric motor which is suitable for rapid ultra-precision positioning. The finite element analysis (FEA) was applied for optimal design and further analysis, then experiments were conducted to investigate its performance. By changing the input signal, the proposed motor was found capable of working in the fast driving mode as well as in the precision positioning mode. When working in the fast driving mode, the motor acts as an ultrasonic motor with maximum no-load speed up to 181.2mm/s and maximum thrust of 1.7N at 200Vp-p. Also, when working in precision positioning mode, the motor can be regarded as a flexible hinge piezoelectric actuator with arbitrary motion in the range of 8μm. The measurable minimum output displacement was found to be 0.08μm, but theoretically, can be even smaller. More importantly, the motor can be quickly and accurately positioned in a large stroke. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Correlation of the turbo-MP RIA with ImmunoCAP FEIA for determination of food allergen-specific immunoglobulin E.

    PubMed

    Kontis, Kris J; Valcour, Andre; Patel, Ashok; Chen, Andy; Wang, Jan; Chow, Julia; Nayak, Narayan

    2006-01-01

    It has been reported that in vitro measurement of food-specific IgE can be used to accurately predict food allergy and reduce the risk associated with double-blinded placebo-controlled food challenges (DBPCFC). Our objective was to assess the performance characteristics of the Hycor Turbo-MP quantitative radioimmunoassay for food-specific IgE and to determine this method's comparability to another assay, the Pharmacia ImmunoCAP fluorescence enzyme immunoassay (FEIA). The dynamic range of the Turbo-MP assay is 0.05 to 100 IU/ml, compared to 0.35 to 100 IU/ml for the FEIA. Performance characteristics of the Turbo-MP assay (ie, reproducibility of the calibration curve, within-run precision, total precision, parallelism, and linearity) were determined using samples from the Hycor serum bank. The precision (CV) of IgE calibrator replicates was <10%. The total precision (CV) of the Turbo-MP assay ranged from 8.8% to 18.4% for specific IgE concentrations between 0.28 to 31.4 IU/ml. Testing of serial dilutions of sera with IgE specificities for egg white, cow's milk, codfish, wheat, peanut, and soybean showed that the assay is linear over the entire dynamic range. Serial dilution data (slopes of 1.01 to 1.10) showed parallelism to serial dilutions of the IgE calibrator (slope of 0.96). The Turbo-MP and FEIA methods were both used for quantitative assays of food-specific IgE in 457 serum samples obtained from a clinical reference laboratory. Comparison of specific IgE results by the Turbo-MP and FEIA methods for 6 major food allergens exhibited a slope of 0.99 (0.92 to 1.03) with a correlation coefficient of 0.81.

  18. High Precision Motion Control System for the Two-Stage Light Gas Gun at the Dynamic Compression Sector

    NASA Astrophysics Data System (ADS)

    Zdanowicz, E.; Guarino, V.; Konrad, C.; Williams, B.; Capatina, D.; D'Amico, K.; Arganbright, N.; Zimmerman, K.; Turneaure, S.; Gupta, Y. M.

    2017-06-01

    The Dynamic Compression Sector (DCS) at the Advanced Photon Source (APS), located at Argonne National Laboratory (ANL), has a diverse set of dynamic compression drivers to obtain time resolved x-ray data in single event, dynamic compression experiments. Because the APS x-ray beam direction is fixed, each driver at DCS must have the capability to move through a large range of linear and angular motions with high precision to accommodate a wide variety of scientific needs. Particularly challenging was the design and implementation of the motion control system for the two-stage light gas gun, which rests on a 26' long structure and weighs over 2 tons. The target must be precisely positioned in the x-ray beam while remaining perpendicular to the gun barrel axis to ensure one-dimensional loading of samples. To accommodate these requirements, the entire structure can pivot through 60° of angular motion and move 10's of inches along four independent linear directions with 0.01° and 10 μm resolution, respectively. This presentation will provide details of how this system was constructed, how it is controlled, and provide examples of the wide range of x-ray/sample geometries that can be accommodated. Work supported by DOE/NNSA.

  19. Simultaneous Determination of Crypto-Chlorogenic Acid, Isoquercetin, and Astragalin Contents in Moringa oleifera Leaf Extracts by TLC-Densitometric Method.

    PubMed

    Vongsak, Boonyadist; Sithisarn, Pongtip; Gritsanapan, Wandee

    2013-01-01

    Moringa oleifera Lamarck (Moringaceae) is used as a multipurpose medicinal plant for the treatment of various diseases. Isoquercetin, astragalin, and crypto-chlorogenic acid have been previously found to be major active components in the leaves of this plant. In this study, a thin-layer-chromatography (TLC-)densitometric method was developed and validated for simultaneous quantification of these major components in the 70% ethanolic extracts of M. oleifera leaves collected from 12 locations. The average amounts of crypto-chlorogenic acid, isoquercetin, and astragalin were found to be 0.0473, 0.0427, and 0.0534% dry weight, respectively. The method was validated for linearity, precision, accuracy, limit of detection, limit of quantitation, and robustness. The linearity was obtained in the range of 100-500 ng/spot with a correlation coefficient (r) over 0.9961. Intraday and interday precisions demonstrated relative standard deviations of less than 5%. The accuracy of the method was confirmed by determining the recovery. The average recoveries of each component from the extracts were in the range of 98.28 to 99.65%. Additionally, the leaves from Chiang Mai province contained the highest amounts of all active components. The proposed TLC-densitometric method was simple, accurate, precise, and cost-effective for routine quality controlling of M. oleifera leaf extracts.

  20. QuEChERS-based purification method coupled to ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) to determine six quaternary ammonium compounds (QACs) in dairy products.

    PubMed

    Xian, Yanping; Dong, Hao; Wu, Yuluan; Guo, Xindong; Hou, Xiangchang; Wang, Bin

    2016-12-01

    QuEChERS-based purification coupled with UPLC-MS/MS method, was developed for six quaternary ammonium compounds (QACs) determination in dairy products. Powder samples were firstly dispersed by water. Protein in liquid milk was precipitated and sample solution was extracted by acetonitrile. QuEChERS-based purification was used to purify the solution. QACs were finally separated by HILIC column and detected in MRM mode of MS/MS under ESI(+). The stable isotope benzyl-2,3,4,5,6-d5-dimethyltetradecylammonium bromide (C14-BAC-d5) was used as an internal standard. This method was validated in terms of linearity, sensitivity, precision, accuracy. Linear relations were favorable for QACs over the selected concentration ranges of 0.2-50μg/L, with correlation coefficients greater than 0.999. The limits of detection (LODs) were in the range of 0.4-14.5μg/kg. Recoveries were between 91.2% and 115% with RSDs of 2.8-7.5% for intra-day precision and 3.7-6.7% for inter-day precision. This validated method was successfully applied to determine the QACs concentrations in dairy products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. UV Spectrophotometric Method for Estimation of Polypeptide-K in Bulk and Tablet Dosage Forms

    NASA Astrophysics Data System (ADS)

    Kaur, P.; Singh, S. Kumar; Gulati, M.; Vaidya, Y.

    2016-01-01

    An analytical method for estimation of polypeptide-k using UV spectrophotometry has been developed and validated for bulk as well as tablet dosage form. The developed method was validated for linearity, precision, accuracy, specificity, robustness, detection, and quantitation limits. The method has shown good linearity over the range from 100.0 to 300.0 μg/ml with a correlation coefficient of 0.9943. The percentage recovery of 99.88% showed that the method was highly accurate. The precision demonstrated relative standard deviation of less than 2.0%. The LOD and LOQ of the method were found to be 4.4 and 13.33, respectively. The study established that the proposed method is reliable, specific, reproducible, and cost-effective for the determination of polypeptide-k.

  2. Development of parallel line analysis criteria for recombinant adenovirus potency assay and definition of a unit of potency.

    PubMed

    Ogawa, Yasushi; Fawaz, Farah; Reyes, Candice; Lai, Julie; Pungor, Erno

    2007-01-01

    Parameter settings of a parallel line analysis procedure were defined by applying statistical analysis procedures to the absorbance data from a cell-based potency bioassay for a recombinant adenovirus, Adenovirus 5 Fibroblast Growth Factor-4 (Ad5FGF-4). The parallel line analysis was performed with a commercially available software, PLA 1.2. The software performs Dixon outlier test on replicates of the absorbance data, performs linear regression analysis to define linear region of the absorbance data, and tests parallelism between the linear regions of standard and sample. Width of Fiducial limit, expressed as a percent of the measured potency, was developed as a criterion for rejection of the assay data and to significantly improve the reliability of the assay results. With the linear range-finding criteria of the software set to a minimum of 5 consecutive dilutions and best statistical outcome, and in combination with the Fiducial limit width acceptance criterion of <135%, 13% of the assay results were rejected. With these criteria applied, the assay was found to be linear over the range of 0.25 to 4 relative potency units, defined as the potency of the sample normalized to the potency of Ad5FGF-4 standard containing 6 x 10(6) adenovirus particles/mL. The overall precision of the assay was estimated to be 52%. Without the application of Fiducial limit width criterion, the assay results were not linear over the range, and an overall precision of 76% was calculated from the data. An absolute unit of potency for the assay was defined by using the parallel line analysis procedure as the amount of Ad5FGF-4 that results in an absorbance value that is 121% of the average absorbance readings of the wells containing cells not infected with the adenovirus.

  3. Design considerations for ultra-precision magnetic bearing supported slides

    NASA Technical Reports Server (NTRS)

    Slocum, Alexander H.; Eisenhaure, David B.

    1993-01-01

    Development plans for a prototype servocontrolled machine with 1 angstrom resolution of linear motion and 50 mm range of travel are described. Two such devices could then be combined to produce a two dimensional machine for probing large planar objects with atomic resolution, the Angstrom Resolution Measuring Machine (ARMM).

  4. Evaluation of the Coat-A-Count sup 125 I fentanyl RIA: Comparison of sup 12 5I RIA and GC/MS-SIM for quantification of fentanyl in case urine specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watts, V.W.; Caplan, Y.H.

    The Coat-A-Count solid phase {sup 125}I Fentanyl Radioimmunoassay was evaluated with respect to linearity and precision using equine urine fortified with fentanyl and then compared with a gas chromatographic/mass spectrometric method for quantification of fentanyl in urine. The RIA assay was found to be linear over the urine fentanyl concentration range of 0.25 to 7.5 ng/mL and precise with coefficients of variation (CV) ranging from 9.6 to 19.3%. The RIA calibrators, ranging in fentanyl concentrations from 0.25 to 7.5 ng/mL, and controls, at mean fentanyl concentrations of 0.46 and 1.32 ng/mL, were compared by both the RIA and GC/MS methods.more » The cross-reactivity with the {sup 125}I RIA test was determined for the fentanyl metabolites, norfentanyl and hydroxyfentanyl, and found to be 5% and 35%, respectively. The illicit fentanyl analogs were found to show significant cross-reactivity, ranging from 20 to 100%. The {sup 125}I RIA was compared to GC/MS quantifications of fentanyl in 35 positive and 20 negative case urine specimens.« less

  5. Development and Validation of Different Ultraviolet-Spectrophotometric Methods for the Estimation of Besifloxacin in Different Simulated Body Fluids.

    PubMed

    Singh, C L; Singh, A; Kumar, S; Kumar, M; Sharma, P K; Majumdar, D K

    2015-01-01

    In the present study a simple, accurate, precise, economical and specific UV-spectrophotometric method for estimation of besifloxacin in bulk and in different pharmaceutical formulation has been developed. The drug shows maximum λmax289 nm in distilled water, simulated tears and phosphate buffer saline. The linearity range of developed methods were in the range of 3-30 μg/ml of drug with a correlation coefficient (r(2)) 0.9992, 0.9989 and 0.9984 with respect to distilled water, simulated tears and phosphate buffer saline, respectively. Reproducibility by repeating methods as %RSD were found to be less than 2%. The limit of detection in different media was found to be 0.62, 0.72 and 0.88 μg/ml, respectively. The limit of quantification was found to be 1.88, 2.10, 2.60 μg/ml, respectively. The proposed method was validated statically according to International Conference on Harmonization guidelines with respect to specificity, linearity, range, accuracy, precision and robustness. The proposed methods of validation were found to be accurate and highly specific for the estimation of besifloxacin in different pharmaceutical formulations.

  6. On-line solid phase extraction using the Prospekt-2 coupled with a liquid chromatography/tandem mass spectrometer for the determination of dextromethorphan, dextrorphan and guaifenesin in human plasma.

    PubMed

    Kuhlenbeck, Debbie L; Eichold, Thomas H; Hoke, Steven H; Baker, Timothy R; Mensen, Robert; Wehmeyer, Kenneth R

    2005-01-01

    An on-line liquid chromatography/tandem mass spectrometry (LC-MS/MS) procedure, using the Prospekt- 2 system, was developed and used for the determination of the levels of the active ingredients of cough/cold medications in human plasma matrix. The experimental configuration allows direct plasma injection by performing on- line solid phase extraction (SPE) on small cartridge columns prior to elution of the analyte(s) onto the analytical column and subsequent MS/MS detection. The quantitative analysis of three analytes with differing polarities, dextromethorphan (DEX), dextrorphan (DET) and guaifenesin (GG) in human plasma presented a significant challenge. Using stable-isotope-labeled internal standards for each analyte, the Prospekt-2 on-line methodology was evaluated for sensitivity, suppression, accuracy, precision, linearity, analyst time, analysis time, cost, carryover and ease of use. The lower limit of quantitation for the on-line SPE procedure for DEX, DET and GG was 0.05, 0.05 and 5.0 ng mL(-1), respectively, using a 0.1 mL sample volume. The linear range for DEX and DET was 0.05-50 ng mL(-1) and was 5-5,000 ng mL(-1) for GG. Accuracy and precision data for five different levels of QC samples were collected over three separate days. Accuracy ranged from 90% to 112% for all three analytes, while the precision, as measured by the %RSD, ranged from 1.5% to 16.0%

  7. A novel methodology for non-linear system identification of battery cells used in non-road hybrid electric vehicles

    NASA Astrophysics Data System (ADS)

    Unger, Johannes; Hametner, Christoph; Jakubek, Stefan; Quasthoff, Marcus

    2014-12-01

    An accurate state of charge (SoC) estimation of a traction battery in hybrid electric non-road vehicles, which possess higher dynamics and power densities than on-road vehicles, requires a precise battery cell terminal voltage model. This paper presents a novel methodology for non-linear system identification of battery cells to obtain precise battery models. The methodology comprises the architecture of local model networks (LMN) and optimal model based design of experiments (DoE). Three main novelties are proposed: 1) Optimal model based DoE, which aims to high dynamically excite the battery cells at load ranges frequently used in operation. 2) The integration of corresponding inputs in the LMN to regard the non-linearities SoC, relaxation, hysteresis as well as temperature effects. 3) Enhancements to the local linear model tree (LOLIMOT) construction algorithm, to achieve a physical appropriate interpretation of the LMN. The framework is applicable for different battery cell chemistries and different temperatures, and is real time capable, which is shown on an industrial PC. The accuracy of the obtained non-linear battery model is demonstrated on cells with different chemistries and temperatures. The results show significant improvement due to optimal experiment design and integration of the battery non-linearities within the LMN structure.

  8. Physics at the e⁺e⁻ linear collider

    DOE PAGES

    Moortgat-Picka, G.; Kronfeld, A. S.

    2015-08-14

    A comprehensive review of physics at an e⁺e⁻ linear collider in the energy range of √s = 92 GeV–3 TeV is presented in view of recent and expected LHC results, experiments from low-energy as well as astroparticle physics. The report focuses in particular on Higgs-boson, top-quark and electroweak precision physics, but also discusses several models of beyond the standard model physics such as supersymmetry, little Higgs models and extra gauge bosons. The connection to cosmology has been analysed as well.

  9. Physics with e{sup +}e{sup -} Linear Colliders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barklow, Timothy L

    2003-05-05

    We describe the physics potential of e{sup +}e{sup -} linear colliders in this report. These machines are planned to operate in the first phase at a center-of-mass energy of 500 GeV, before being scaled up to about 1 TeV. In the second phase of the operation, a final energy of about 2 TeV is expected. The machines will allow us to perform precision tests of the heavy particles in the Standard Model, the top quark and the electroweak bosons. They are ideal facilities for exploring the properties of Higgs particles, in particular in the intermediate mass range. New vector bosonsmore » and novel matter particles in extended gauge theories can be searched for and studied thoroughly. The machines provide unique opportunities for the discovery of particles in supersymmetric extensions of the Standard Model, the spectrum of Higgs particles, the supersymmetric partners of the electroweak gauge and Higgs bosons, and of the matter particles. High precision analyses of their properties and interactions will allow for extrapolations to energy scales close to the Planck scale where gravity becomes significant. In alternative scenarios, like compositeness models, novel matter particles and interactions can be discovered and investigated in the energy range above the existing colliders up to the TeV scale. Whatever scenario is realized in Nature, the discovery potential of e{sup +}e{sup -} linear colliders and the high-precision with which the properties of particles and their interactions can be analyzed, define an exciting physics programme complementary to hadron machines.« less

  10. Three-dimensional repositioning accuracy of semiadjustable articulator cast mounting systems.

    PubMed

    Tan, Ming Yi; Ung, Justina Youlin; Low, Ada Hui Yin; Tan, En En; Tan, Keson Beng Choon

    2014-10-01

    In spite of its importance in prosthesis precision and quality, the 3-dimensional repositioning accuracy of cast mounting systems has not been reported in detail. The purpose of this study was to quantify the 3-dimensional repositioning accuracy of 6 selected cast mounting systems. Five magnetic mounting systems were compared with a conventional screw-on system. Six systems on 3 semiadjustable articulators were evaluated: Denar Mark II with conventional screw-on mounting plates (DENSCR) and magnetic mounting system with converter plates (DENCON); Denar Mark 330 with in-built magnetic mounting system (DENMAG) and disposable mounting plates; and Artex CP with blue (ARTBLU), white (ARTWHI), and black (ARTBLA) magnetic mounting plates. Test casts with 3 high-precision ceramic ball bearings at the mandibular central incisor (Point I) and the right and left second molar (Point R; Point L) positions were mounted on 5 mounting plates (n=5) for all 6 systems. Each cast was repositioned 10 times by 4 operators in random order. Nine linear (Ix, Iy, Iz; Rx, Ry, Rz; Lx, Ly, Lz) and 3 angular (anteroposterior, mediolateral, twisting) displacements were measured with a coordinate measuring machine. The mean standard deviations of the linear and angular displacements defined repositioning accuracy. Anteroposterior linear repositioning accuracy ranged from 23.8 ±3.7 μm (DENCON) to 4.9 ±3.2 μm (DENSCR). Mediolateral linear repositioning accuracy ranged from 46.0 ±8.0 μm (DENCON) to 3.7 ±1.5 μm (ARTBLU), and vertical linear repositioning accuracy ranged from 7.2 ±9.6 μm (DENMAG) to 1.5 ±0.9 μm (ARTBLU). Anteroposterior angular repositioning accuracy ranged from 0.0084 ±0.0080 degrees (DENCON) to 0.0020 ±0.0006 degrees (ARTBLU), and mediolateral angular repositioning accuracy ranged from 0.0120 ±0.0111 degrees (ARTWHI) to 0.0027 ±0.0008 degrees (ARTBLU). Twisting angular repositioning accuracy ranged from 0.0419 ±0.0176 degrees (DENCON) to 0.0042 ±0.0038 degrees (ARTBLA). One-way ANOVA found significant differences (P<.05) among all systems for Iy, Ry, Lx, Ly, and twisting. Generally, vertical linear displacements were less likely to reach the threshold of clinical detectability compared with anteroposterior or mediolateral linear displacements. The overall repositioning accuracy of DENSCR was comparable with 4 magnetic mounting systems (DENMAG, ARTBLU, ARTWHI, ARTBLA). DENCON exhibited the worst repositioning accuracy for Iy, Ry, Lx, Ly, and twisting. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. Bit Grooming: Statistically accurate precision-preserving quantization with compression, evaluated in the netCDF operators (NCO, v4.4.8+)

    DOE PAGES

    Zender, Charles S.

    2016-09-19

    Geoscientific models and measurements generate false precision (scientifically meaningless data bits) that wastes storage space. False precision can mislead (by implying noise is signal) and be scientifically pointless, especially for measurements. By contrast, lossy compression can be both economical (save space) and heuristic (clarify data limitations) without compromising the scientific integrity of data. Data quantization can thus be appropriate regardless of whether space limitations are a concern. We introduce, implement, and characterize a new lossy compression scheme suitable for IEEE floating-point data. Our new Bit Grooming algorithm alternately shaves (to zero) and sets (to one) the least significant bits ofmore » consecutive values to preserve a desired precision. This is a symmetric, two-sided variant of an algorithm sometimes called Bit Shaving that quantizes values solely by zeroing bits. Our variation eliminates the artificial low bias produced by always zeroing bits, and makes Bit Grooming more suitable for arrays and multi-dimensional fields whose mean statistics are important. Bit Grooming relies on standard lossless compression to achieve the actual reduction in storage space, so we tested Bit Grooming by applying the DEFLATE compression algorithm to bit-groomed and full-precision climate data stored in netCDF3, netCDF4, HDF4, and HDF5 formats. Bit Grooming reduces the storage space required by initially uncompressed and compressed climate data by 25–80 and 5–65 %, respectively, for single-precision values (the most common case for climate data) quantized to retain 1–5 decimal digits of precision. The potential reduction is greater for double-precision datasets. When used aggressively (i.e., preserving only 1–2 digits), Bit Grooming produces storage reductions comparable to other quantization techniques such as Linear Packing. Unlike Linear Packing, whose guaranteed precision rapidly degrades within the relatively narrow dynamic range of values that it can compress, Bit Grooming guarantees the specified precision throughout the full floating-point range. Data quantization by Bit Grooming is irreversible (i.e., lossy) yet transparent, meaning that no extra processing is required by data users/readers. Hence Bit Grooming can easily reduce data storage volume without sacrificing scientific precision or imposing extra burdens on users.« less

  12. Extraction and LC determination of lysine clonixinate salt in water/oil microemulsions.

    PubMed

    Pineros, I; Ballesteros, P; Lastres, J L

    2002-02-01

    A new reversed-phase high performance liquid chromatography method has been developed and validated for the quantitative determination of lysine clonixinate salt in water/oil microemulsions. The mobile phase was acetonitrile-buffer phosphate pH 3.3. Detection was UV absorbance at 252 nm. The precision and accurately of the method were excellent. The established linearity range was 5-60 microg ml(-1) (r(2)=0.999). Microemulsions samples were dispersed with chloroform and extracted lysine clonixinate salt with water. This easy method employing chloroformic extraction has been done three times. The recovery of lysine clonixinate salt from spiked placebo and microemulsion were >90% over the linear range.

  13. Microbiological assay for the determination of meropenem in pharmaceutical dosage form.

    PubMed

    Mendez, Andreas S L; Weisheimer, Vanessa; Oppe, Tércio P; Steppe, Martin; Schapoval, Elfrides E S

    2005-04-01

    Meropenem is a highly active carbapenem antibiotic used in the treatment of a wide range of serious infections. The present work reports a microbiological assay, applying the cylinder-plate method, for the determination of meropenem in powder for injection. The validation method yielded good results and included linearity, precision, accuracy and specificity. The assay is based on the inhibitory effect of meropenem upon the strain of Micrococcus luteus ATCC 9341 used as the test microorganism. The results of assay were treated statistically by analysis of variance (ANOVA) and were found to be linear (r=0.9999) in the range of 1.5-6.0 microg ml(-1), precise (intra-assay: R.S.D.=0.29; inter-assay: R.S.D.=0.94) and accurate. A preliminary stability study of meropenem was performed to show that the microbiological assay is specific for the determination of meropenem in the presence of its degradation products. The degraded samples were also analysed by the HPLC method. The proposed method allows the quantitation of meropenem in pharmaceutical dosage form and can be used for the drug analysis in routine quality control.

  14. Development and validation of a HPTLC method for simultaneous estimation of lornoxicam and thiocolchicoside in combined dosage form.

    PubMed

    Sahoo, Madhusmita; Syal, Pratima; Hable, Asawaree A; Raut, Rahul P; Choudhari, Vishnu P; Kuchekar, Bhanudas S

    2011-07-01

    To develop a simple, precise, rapid and accurate HPTLC method for the simultaneous estimation of Lornoxicam (LOR) and Thiocolchicoside (THIO) in bulk and pharmaceutical dosage forms. The separation of the active compounds from pharmaceutical dosage form was carried out using methanol:chloroform:water (9.6:0.2:0.2 v/v/v) as the mobile phase and no immiscibility issues were found. The densitometric scanning was carried out at 377 nm. The method was validated for linearity, accuracy, precision, LOD (Limit of Detection), LOQ (Limit of Quantification), robustness and specificity. The Rf values (±SD) were found to be 0.84 ± 0.05 for LOR and 0.58 ± 0.05 for THIO. Linearity was obtained in the range of 60-360 ng/band for LOR and 30-180 ng/band for THIO with correlation coefficients r(2) = 0.998 and 0.999, respectively. The percentage recovery for both the analytes was in the range of 98.7-101.2 %. The proposed method was optimized and validated as per the ICH guidelines.

  15. Generalized Nonlinear Chirp Scaling Algorithm for High-Resolution Highly Squint SAR Imaging.

    PubMed

    Yi, Tianzhu; He, Zhihua; He, Feng; Dong, Zhen; Wu, Manqing

    2017-11-07

    This paper presents a modified approach for high-resolution, highly squint synthetic aperture radar (SAR) data processing. Several nonlinear chirp scaling (NLCS) algorithms have been proposed to solve the azimuth variance of the frequency modulation rates that are caused by the linear range walk correction (LRWC). However, the azimuth depth of focusing (ADOF) is not handled well by these algorithms. The generalized nonlinear chirp scaling (GNLCS) algorithm that is proposed in this paper uses the method of series reverse (MSR) to improve the ADOF and focusing precision. It also introduces a high order processing kernel to avoid the range block processing. Simulation results show that the GNLCS algorithm can enlarge the ADOF and focusing precision for high-resolution highly squint SAR data.

  16. Performance characteristics of two bioassays and high-performance liquid chromatography for determination of flucytosine in serum.

    PubMed Central

    St-Germain, G; Lapierre, S; Tessier, D

    1989-01-01

    We compared the accuracy and precision of two microbiological methods and one high-pressure liquid chromatography (HPLC) procedure used to measure the concentrations of flucytosine in serum. On the basis of an analysis of six standards, all methods were judged reliable within acceptable limits for clinical use. With the biological methods, a slight loss of linearity was observed in the 75- to 100-micrograms/ml range. Compared with the bioassays, the HPLC method did not present linearity problems and was more precise and accurate in the critical zone of 100 micrograms/ml. On average, results obtained with patient sera containing 50 to 100 micrograms of flucytosine per ml were 10.6% higher with the HPLC method than with the bioassays. Standards for the biological assays may be prepared in serum or water. PMID:2802566

  17. Stability indicating high performance thin-layer chromatographic method for simultaneous estimation of pantoprazole sodium and itopride hydrochloride in combined dosage form

    PubMed Central

    Bageshwar, Deepak; Khanvilkar, Vineeta; Kadam, Vilasrao

    2011-01-01

    A specific, precise and stability indicating high-performance thin-layer chromatographic method for simultaneous estimation of pantoprazole sodium and itopride hydrochloride in pharmaceutical formulations was developed and validated. The method employed TLC aluminium plates precoated with silica gel 60F254 as the stationary phase. The solvent system consisted of methanol:water:ammonium acetate; 4.0:1.0:0.5 (v/v/v). This system was found to give compact and dense spots for both itopride hydrochloride (Rf value of 0.55±0.02) and pantoprazole sodium (Rf value of 0.85±0.04). Densitometric analysis of both drugs was carried out in the reflectance–absorbance mode at 289 nm. The linear regression analysis data for the calibration plots showed a good linear relationship with R2=0.9988±0.0012 in the concentration range of 100–400 ng for pantoprazole sodium. Also, the linear regression analysis data for the calibration plots showed a good linear relationship with R2=0.9990±0.0008 in the concentration range of 200–1200 ng for itopride hydrochloride. The method was validated for specificity, precision, robustness and recovery. Statistical analysis proves that the method is repeatable and selective for the estimation of both the said drugs. As the method could effectively separate the drug from its degradation products, it can be employed as a stability indicating method. PMID:29403710

  18. Stability indicating high performance thin-layer chromatographic method for simultaneous estimation of pantoprazole sodium and itopride hydrochloride in combined dosage form.

    PubMed

    Bageshwar, Deepak; Khanvilkar, Vineeta; Kadam, Vilasrao

    2011-11-01

    A specific, precise and stability indicating high-performance thin-layer chromatographic method for simultaneous estimation of pantoprazole sodium and itopride hydrochloride in pharmaceutical formulations was developed and validated. The method employed TLC aluminium plates precoated with silica gel 60F 254 as the stationary phase. The solvent system consisted of methanol:water:ammonium acetate; 4.0:1.0:0.5 (v/v/v). This system was found to give compact and dense spots for both itopride hydrochloride ( R f value of 0.55±0.02) and pantoprazole sodium ( R f value of 0.85±0.04). Densitometric analysis of both drugs was carried out in the reflectance-absorbance mode at 289 nm. The linear regression analysis data for the calibration plots showed a good linear relationship with R 2 =0.9988±0.0012 in the concentration range of 100-400 ng for pantoprazole sodium. Also, the linear regression analysis data for the calibration plots showed a good linear relationship with R 2 =0.9990±0.0008 in the concentration range of 200-1200 ng for itopride hydrochloride. The method was validated for specificity, precision, robustness and recovery. Statistical analysis proves that the method is repeatable and selective for the estimation of both the said drugs. As the method could effectively separate the drug from its degradation products, it can be employed as a stability indicating method.

  19. Estimation of L-dopa from Mucuna pruriens LINN and formulations containing M. pruriens by HPTLC method.

    PubMed

    Modi, Ketan Pravinbhai; Patel, Natvarlal Manilal; Goyal, Ramesh Kishorilal

    2008-03-01

    A selective, precise, and accurate high-performance thin-layer chromatographic (HPTLC) method has been developed for the analysis of L-dopa in Mucuna pruriens seed extract and its formulations. The method involves densitometric evaluation of L-dopa after resolving it by HPTLC on silica gel plates with n-butanol-acetic acid-water (4.0+1.0+1.0, v/v) as the mobile phase. Densitometric analysis of L-dopa was carried out in the absorbance mode at 280 nm. The relationship between the concentration of L-dopa and corresponding peak areas was found to be linear in the range of 100 to 1200 ng/spot. The method was validated for precision (inter and intraday), repeatability, and accuracy. Mean recovery was 100.30%. The relative standard deviation (RSD) values of the precision were found to be in the range 0.64-1.52%. In conclusion, the proposed TLC method was found to be precise, specific and accurate and can be used for identification and quantitative determination of L-dopa in herbal extract and its formulations.

  20. Development and validation of a UV-spectrophotometric method for the determination of pheniramine maleate and its stability studies

    NASA Astrophysics Data System (ADS)

    Raghu, M. S.; Basavaiah, K.; Ramesh, P. J.; Abdulrahman, Sameer A. M.; Vinay, K. B.

    2012-03-01

    A sensitive, precise, and cost-effective UV-spectrophotometric method is described for the determination of pheniramine maleate (PAM) in bulk drug and tablets. The method is based on the measurement of absorbance of a PAM solution in 0.1 N HCl at 264 nm. As per the International Conference on Harmonization (ICH) guidelines, the method was validated for linearity, accuracy, precision, limits of detection (LOD) and quantification (LOQ), and robustness and ruggedness. A linear relationship between absorbance and concentration of PAM in the range of 2-40 μg/ml with a correlation coefficient (r) of 0.9998 was obtained. The LOD and LOQ values were found to be 0.18 and 0.39 μg/ml PAM, respectively. The precision of the method was satisfactory: the value of relative standard deviation (RSD) did not exceed 3.47%. The proposed method was applied successfully to the determination of PAM in tablets with good accuracy and precision. Percentages of the label claims ranged from 101.8 to 102.01% with the standard deviation (SD) from 0.64 to 0.72%. The accuracy of the method was further ascertained by recovery studies via a standard addition procedure. In addition, the forced degradation of PAM was conducted in accordance with the ICH guidelines. Acidic and basic hydrolysis, thermal stress, peroxide, and photolytic degradation were used to assess the stability-indicating power of the method. A substantial degradation was observed during oxidative and alkaline degradations. No degradation was observed under other stress conditions.

  1. RP-HPLC method development and validation for simultaneous estimation of atorvastatin calcium and pioglitazone hydrochloride in pharmaceutical dosage form.

    PubMed

    Peraman, Ramalingam; Mallikarjuna, Sasikala; Ammineni, Pravalika; Kondreddy, Vinod kumar

    2014-10-01

    A simple, selective, rapid, precise and economical reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for simultaneous estimation of atorvastatin calcium (ATV) and pioglitazone hydrochloride (PIO) from pharmaceutical formulation. The method is carried out on a C8 (25 cm × 4.6 mm i.d., 5 μm) column with a mobile phase consisting of acetonitrile (ACN):water (pH adjusted to 6.2 using o-phosphoric acid) in the ratio of 45:55 (v/v). The retention time of ATV and PIO is 4.1 and 8.1 min, respectively, with the flow rate of 1 mL/min with diode array detector detection at 232 nm. The linear regression analysis data from the linearity plot showed good linear relationship with a correlation coefficient (R(2)) value for ATV and PIO of 0.9998 and 0.9997 in the concentration range of 10-80 µg mL(-1), respectively. The relative standard deviation for intraday precision has been found to be <2.0%. The method is validated according to the ICH guidelines. The developed method is validated in terms of specificity, selectivity, accuracy, precision, linearity, limit of detection, limit of quantitation and solution stability. The proposed method can be used for simultaneous estimation of these drugs in marketed dosage forms. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Simultaneous Determination of Crypto-Chlorogenic Acid, Isoquercetin, and Astragalin Contents in Moringa oleifera Leaf Extracts by TLC-Densitometric Method

    PubMed Central

    Vongsak, Boonyadist; Sithisarn, Pongtip; Gritsanapan, Wandee

    2013-01-01

    Moringa oleifera Lamarck (Moringaceae) is used as a multipurpose medicinal plant for the treatment of various diseases. Isoquercetin, astragalin, and crypto-chlorogenic acid have been previously found to be major active components in the leaves of this plant. In this study, a thin-layer-chromatography (TLC-)densitometric method was developed and validated for simultaneous quantification of these major components in the 70% ethanolic extracts of M. oleifera leaves collected from 12 locations. The average amounts of crypto-chlorogenic acid, isoquercetin, and astragalin were found to be 0.0473, 0.0427, and 0.0534% dry weight, respectively. The method was validated for linearity, precision, accuracy, limit of detection, limit of quantitation, and robustness. The linearity was obtained in the range of 100–500 ng/spot with a correlation coefficient (r) over 0.9961. Intraday and interday precisions demonstrated relative standard deviations of less than 5%. The accuracy of the method was confirmed by determining the recovery. The average recoveries of each component from the extracts were in the range of 98.28 to 99.65%. Additionally, the leaves from Chiang Mai province contained the highest amounts of all active components. The proposed TLC-densitometric method was simple, accurate, precise, and cost-effective for routine quality controlling of M. oleifera leaf extracts. PMID:23533530

  3. Highly sensitive spectrofluorimetric determination of lomefloxacin in spiked human plasma, urine and pharmaceutical preparations.

    PubMed

    Ulu, Sevgi Tatar

    2009-09-01

    A sensitive, simple and selective spectrofluorimetric method was developed for the determination of lomefloxacin in biological fluids and pharmaceutical preparations. The method is based on the reaction between the drug and 4-chloro-7-nitrobenzodioxazole in borate buffer of pH 8.5 to yield a highly fluorescent derivative that is measured at 533 nm after excitation at 433 nm. The calibration curves were linear over the concentration ranges of 12.5-625, 15-1500 and 20-2000 ng/mL for plasma, urine and standard solution, respectively. The limits of detection were 4.0 ng/mL in plasma, 5.0 ng/mL in urine and 7.0 ng/mL in standard solution. The intra-assay accuracy and precision in plasma ranged from 0.032 to 2.40% and 0.23 to 0.36%, respectively, while inter-assay accuracy and precision ranged from 0.45 to 2.10% and 0.25 to 0.38%, respectively. The intra-assay accuracy and precision estimated on spiked samples in urine ranged from 1.27 to 4.20% and 0.12 to 0.24%, respectively, while inter-assay accuracy and precision ranged from 1.60 to 4.00% and 0.14 to 0.25%, respectively. The mean recovery of lomefloxacin from plasma and urine was 98.34 and 98.43%, respectively. The method was successfully applied to the determination of lomefloxacin in pharmaceuticals and biological fluids.

  4. Use of Longitudinal Data in Genetic Studies in the Genome-wide Association Studies Era: Summary of Group 14

    PubMed Central

    Kerner, Berit; North, Kari E; Fallin, M Daniele

    2010-01-01

    Participants analyzed actual and simulated longitudinal data from the Framingham Heart Study for various metabolic and cardiovascular traits. The genetic information incorporated into these investigations ranged from selected single-nucleotide polymorphisms to genome-wide association arrays. Genotypes were incorporated using a broad range of methodological approaches including conditional logistic regression, linear mixed models, generalized estimating equations, linear growth curve estimation, growth modeling, growth mixture modeling, population attributable risk fraction based on survival functions under the proportional hazards models, and multivariate adaptive splines for the analysis of longitudinal data. The specific scientific questions addressed by these different approaches also varied, ranging from a more precise definition of the phenotype, bias reduction in control selection, estimation of effect sizes and genotype associated risk, to direct incorporation of genetic data into longitudinal modeling approaches and the exploration of population heterogeneity with regard to longitudinal trajectories. The group reached several overall conclusions: 1) The additional information provided by longitudinal data may be useful in genetic analyses. 2) The precision of the phenotype definition as well as control selection in nested designs may be improved, especially if traits demonstrate a trend over time or have strong age-of-onset effects. 3) Analyzing genetic data stratified for high-risk subgroups defined by a unique development over time could be useful for the detection of rare mutations in common multi-factorial diseases. 4) Estimation of the population impact of genomic risk variants could be more precise. The challenges and computational complexity demanded by genome-wide single-nucleotide polymorphism data were also discussed. PMID:19924713

  5. Theoretically guided analytical method development and validation for the estimation of rifampicin in a mixture of isoniazid and pyrazinamide by UV spectrophotometer

    NASA Astrophysics Data System (ADS)

    Khan, Mohammad F.; Rita, Shamima A.; Kayser, Md. Shahidulla; Islam, Md. Shariful; Asad, Sharmeen; Bin Rashid, Ridwan; Bari, Md. Abdul; Rahman, Muhammed M.; Al Aman, D. A. Anwar; Setu, Nurul I.; Banoo, Rebecca; Rashid, Mohammad A.

    2017-04-01

    A simple, rapid, economic, accurate and precise method for the estimation of rifampicin in a mixture of isoniazid and pyrazinamide by UV spectrophotometeric technique (guided by the theoretical investigation of physicochemical properties) was developed and validated. Theoretical investigations revealed that isoniazid and pyrazinamide both were freely soluble in water and slightly soluble in ethyl acetate whereas rifampicin was practically insoluble in water but freely soluble in ethyl acetate. This indicates that ethyl acetate is an effective solvent for the extraction of rifampicin from a water mixture of isoniazid and pyrazinamide. Computational study indicated that pH range of 6.0-8.0 would favor the extraction of rifampicin. Rifampicin is separated from isoniazid and pyrazinamide at pH 7.4 ± 0.1 by extracting with ethyl acetate. The ethyl acetate was then analyzed at λmax of 344.0 nm. The developed method was validated for linearity, accuracy and precision according to ICH guidelines. The proposed method exhibited good linearity over the concentration range of 2.5 - 35.0 µg/mL. The intraday and inter-day precision in terms of % RSD ranged from 1.09 - 1.70% and 1.63 - 2.99%, respectively. The accuracy (in terms of recovery) of the method varied from of 96.7 ± 0.9 to 101.1 ± 0.4%. The LOD and LOQ were found to be 0.83 and 2.52 µg/mL, respectively. In addition, the developed method was successfully applied to assay rifampicin combination (isoniazid and pyrazinamide) brands available in Bangladesh.

  6. Determining CDOM Absorption Spectra in Diverse Aquatic Environments Using a Multiple Pathlength, Liquid Core Waveguide System

    NASA Technical Reports Server (NTRS)

    Miller, Richard L.; Belz, Mathias; DelCastillo, Carlos; Trzaska, Rick

    2001-01-01

    We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, aCDOM, and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values and showed a linear response across all four pathlengths. Values of aCDOM measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of aCDOM for MPLCW measurements was 0.002 - 231.5 m-1. At low CDOM concentrations spectrophotometric aCDOM were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples.

  7. Physics at the [Formula: see text] linear collider.

    PubMed

    Moortgat-Pick, G; Baer, H; Battaglia, M; Belanger, G; Fujii, K; Kalinowski, J; Heinemeyer, S; Kiyo, Y; Olive, K; Simon, F; Uwer, P; Wackeroth, D; Zerwas, P M; Arbey, A; Asano, M; Bagger, J; Bechtle, P; Bharucha, A; Brau, J; Brümmer, F; Choi, S Y; Denner, A; Desch, K; Dittmaier, S; Ellwanger, U; Englert, C; Freitas, A; Ginzburg, I; Godfrey, S; Greiner, N; Grojean, C; Grünewald, M; Heisig, J; Höcker, A; Kanemura, S; Kawagoe, K; Kogler, R; Krawczyk, M; Kronfeld, A S; Kroseberg, J; Liebler, S; List, J; Mahmoudi, F; Mambrini, Y; Matsumoto, S; Mnich, J; Mönig, K; Mühlleitner, M M; Pöschl, R; Porod, W; Porto, S; Rolbiecki, K; Schmitt, M; Serpico, P; Stanitzki, M; Stål, O; Stefaniak, T; Stöckinger, D; Weiglein, G; Wilson, G W; Zeune, L; Moortgat, F; Xella, S; Bagger, J; Brau, J; Ellis, J; Kawagoe, K; Komamiya, S; Kronfeld, A S; Mnich, J; Peskin, M; Schlatter, D; Wagner, A; Yamamoto, H

    A comprehensive review of physics at an [Formula: see text] linear collider in the energy range of [Formula: see text] GeV-3 TeV is presented in view of recent and expected LHC results, experiments from low-energy as well as astroparticle physics. The report focusses in particular on Higgs-boson, top-quark and electroweak precision physics, but also discusses several models of beyond the standard model physics such as supersymmetry, little Higgs models and extra gauge bosons. The connection to cosmology has been analysed as well.

  8. Characterizing Accuracy and Precision of Glucose Sensors and Meters

    PubMed Central

    2014-01-01

    There is need for a method to describe precision and accuracy of glucose measurement as a smooth continuous function of glucose level rather than as a step function for a few discrete ranges of glucose. We propose and illustrate a method to generate a “Glucose Precision Profile” showing absolute relative deviation (ARD) and /or %CV versus glucose level to better characterize measurement errors at any glucose level. We examine the relationship between glucose measured by test and comparator methods using linear regression. We examine bias by plotting deviation = (test – comparator method) versus glucose level. We compute the deviation, absolute deviation (AD), ARD, and standard deviation (SD) for each data pair. We utilize curve smoothing procedures to minimize the effects of random sampling variability to facilitate identification and display of the underlying relationships between ARD or %CV and glucose level. AD, ARD, SD, and %CV display smooth continuous relationships versus glucose level. Estimates of MARD and %CV are subject to relatively large errors in the hypoglycemic range due in part to a markedly nonlinear relationship with glucose level and in part to the limited number of observations in the hypoglycemic range. The curvilinear relationships of ARD and %CV versus glucose level are helpful when characterizing and comparing the precision and accuracy of glucose sensors and meters. PMID:25037194

  9. The Magsat precision vector magnetometer

    NASA Technical Reports Server (NTRS)

    Acuna, M. H.

    1980-01-01

    This paper examines the Magsat precision vector magnetometer which is designed to measure projections of the ambient field in three orthogonal directions. The system contains a highly stable and linear triaxial fluxgate magnetometer with a dynamic range of + or - 2000 nT (1 nT = 10 to the -9 weber per sq m). The magnetometer electronics, analog-to-digital converter, and digitally controlled current sources are implemented with redundant designs to avoid a loss of data in case of failures. Measurements are carried out with an accuracy of + or - 1 part in 64,000 in magnitude and 5 arcsec in orientation (1 arcsec = 0.00028 deg).

  10. Aircraft MSS data registration and vegetation classification of wetland change detection

    USGS Publications Warehouse

    Christensen, E.J.; Jensen, J.R.; Ramsey, Elijah W.; Mackey, H.E.

    1988-01-01

    Portions of the Savannah River floodplain swamp were evaluated for vegetation change using high resolution (5a??6 m) aircraft multispectral scanner (MSS) data. Image distortion from aircraft movement prevented precise image-to-image registration in some areas. However, when small scenes were used (200-250 ha), a first-order linear transformation provided registration accuracies of less than or equal to one pixel. A larger area was registered using a piecewise linear method. Five major wetland classes were identified and evaluated for change. Phenological differences and the variable distribution of vegetation limited wetland type discrimination. Using unsupervised methods and ground-collected vegetation data, overall classification accuracies ranged from 84 per cent to 87 per cent for each scene. Results suggest that high-resolution aircraft MSS data can be precisely registered, if small areas are used, and that wetland vegetation change can be accurately detected and monitored.

  11. Generalized Nonlinear Chirp Scaling Algorithm for High-Resolution Highly Squint SAR Imaging

    PubMed Central

    He, Zhihua; He, Feng; Dong, Zhen; Wu, Manqing

    2017-01-01

    This paper presents a modified approach for high-resolution, highly squint synthetic aperture radar (SAR) data processing. Several nonlinear chirp scaling (NLCS) algorithms have been proposed to solve the azimuth variance of the frequency modulation rates that are caused by the linear range walk correction (LRWC). However, the azimuth depth of focusing (ADOF) is not handled well by these algorithms. The generalized nonlinear chirp scaling (GNLCS) algorithm that is proposed in this paper uses the method of series reverse (MSR) to improve the ADOF and focusing precision. It also introduces a high order processing kernel to avoid the range block processing. Simulation results show that the GNLCS algorithm can enlarge the ADOF and focusing precision for high-resolution highly squint SAR data. PMID:29112151

  12. Validation of a spectrophotometric assay method for bisoprolol using picric acid.

    PubMed

    Panainte, Alina-Diana; Bibire, Nela; Tântaru, Gladiola; Apostu, M; Vieriu, Mădălina

    2013-01-01

    Bisoprolol is a drug belonging to beta blockers drugs used primarily for the treatment of cardiovascular diseases. A spectrophotometric method for quantitative determination of bisoprolol was developed based on the formation of a complex combination between bisoprolol and picric acid. The complex combination of bisoprolol and picric acid has a maximum absorbance peak at 420 nm. Optimum working conditions were established and the method was validated. The method presented a good linearity in the concentration range 5-120 microg/ml (regression coefficient r2 = 0.9992). The RSD for the precision of the method was 1.74 and for the intermediate precision 1.43, and recovery values ranged between 98.25-101.48%. The proposed and validated spectrophotometric method for the determination of bisoprolol is simple and cost effective.

  13. Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods

    PubMed Central

    Atila, Alptug; Yilmaz, Bilal

    2015-01-01

    In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containing 0.1 M TBACIO4. The well-defined oxidation peak was observed at 1.21 V. The calibration curves were linear for bosentan at the concentration range of 5-40 µg/mL for LSV and 5-35 µg/mL for SWV and DPV methods, respectively. Intra- and inter-day precision values for bosentan were less than 4.92, and accuracy (relative error) was better than 6.29%. The mean recovery of bosentan was 100.7% for pharmaceutical preparations. No interference was found from two tablet excipients at the selected assay conditions. Developed methods in this study are accurate, precise and can be easily applied to Tracleer and Diamond tablets as pharmaceutical preparation. PMID:25901151

  14. Development and Validation of High Performance Liquid Chromatography Method for Determination Atorvastatin in Tablet

    NASA Astrophysics Data System (ADS)

    Yugatama, A.; Rohmani, S.; Dewangga, A.

    2018-03-01

    Atorvastatin is the primary choice for dyslipidemia treatment. Due to patent expiration of atorvastatin, the pharmaceutical industry makes copy of the drug. Therefore, the development methods for tablet quality tests involving atorvastatin concentration on tablets needs to be performed. The purpose of this research was to develop and validate the simple atorvastatin tablet analytical method by HPLC. HPLC system used in this experiment consisted of column Cosmosil C18 (150 x 4,6 mm, 5 µm) as the stationary reverse phase chomatography, a mixture of methanol-water at pH 3 (80:20 v/v) as the mobile phase, flow rate of 1 mL/min, and UV detector at wavelength of 245 nm. Validation methods were including: selectivity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The results of this study indicate that the developed method had good validation including selectivity, linearity, accuracy, precision, LOD, and LOQ for analysis of atorvastatin tablet content. LOD and LOQ were 0.2 and 0.7 ng/mL, and the linearity range were 20 - 120 ng/mL.

  15. Determination of bosentan in pharmaceutical preparations by linear sweep, square wave and differential pulse voltammetry methods.

    PubMed

    Atila, Alptug; Yilmaz, Bilal

    2015-01-01

    In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containing 0.1 M TBACIO4. The well-defined oxidation peak was observed at 1.21 V. The calibration curves were linear for bosentan at the concentration range of 5-40 µg/mL for LSV and 5-35 µg/mL for SWV and DPV methods, respectively. Intra- and inter-day precision values for bosentan were less than 4.92, and accuracy (relative error) was better than 6.29%. The mean recovery of bosentan was 100.7% for pharmaceutical preparations. No interference was found from two tablet excipients at the selected assay conditions. Developed methods in this study are accurate, precise and can be easily applied to Tracleer and Diamond tablets as pharmaceutical preparation.

  16. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of chromium in water by graphite furnace atomic absorption spectrophotometry

    USGS Publications Warehouse

    McLain, B.J.

    1993-01-01

    Graphite furnace atomic absorption spectrophotometry is a sensitive, precise, and accurate method for the determination of chromium in natural water samples. The detection limit for this analytical method is 0.4 microg/L with a working linear limit of 25.0 microg/L. The precision at the detection limit ranges from 20 to 57 percent relative standard deviation (RSD) with an improvement to 4.6 percent RSD for concentrations more than 3 microg/L. Accuracy of this method was determined for a variety of reference standards that was representative of the analytical range. The results were within the established standard deviations. Samples were spiked with known concentrations of chromium with recoveries ranging from 84 to 122 percent. In addition, a comparison of data between graphite furnace atomic absorption spectrophotometry and direct-current plasma atomic emission spectrometry resulted in suitable agreement between the two methods, with an average deviation of +/- 2.0 microg/L throughout the analytical range.

  17. Liquid chromatography/tandem mass spectrometry method for simultaneous determination of cocaine and its metabolite (-)ecgonine methyl ester in human acidified stabilized plasma samples.

    PubMed

    Liu, Yongzhen; Zheng, Bo; Strafford, Stephanie; Orugunty, Ravi; Sullivan, Michael; Gus, Jeffrey; Heidbreder, Christian; Fudala, Paul J; Nasser, Azmi

    2014-06-15

    Two simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) methods (low range and high range) were developed and validated for the quantification of cocaine and its metabolite (-)ecgonine methyl ester (EME) in human acidified stabilized plasma samples. In the low range assay, cocaine and the internal standard, cocaine-D3, were extracted using a single step liquid-liquid extraction from human acidified stabilized plasma. For the high range assay, human acidified stabilized plasma containing cocaine, EME, and the internal standards, cocaine-D3 and EME-D3, was mixed with acetonitrile, and the protein precipitate was separated by centrifugation. Both cocaine and EME extracted from both assays were separated on a HILIC column and detected in positive ion mode using multiple reaction monitoring (MRM). Both methods were validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. The linear range for the low range assay was 0.01-5ng/mL for cocaine; in the high range assay values were 5-1000ng/mL for cocaine and 1-200ng/mL for EME. The correlation coefficient (R(2)) values for both assays were 0.993 or greater. The precision and accuracy for intra-day and inter-day were better than 13.0%. The recovery was above 85% and matrix effects were low with the matrix factor ranging from 0.817 to 1.10 for both analytes in both assays. The validated methods were successfully used to quantify the plasma concentrations of cocaine and EME in clinical pharmacokinetic and pharmacodynamic studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. An improved triangulation laser rangefinder using a custom CMOS HDR linear image sensor

    NASA Astrophysics Data System (ADS)

    Liscombe, Michael

    3-D triangulation laser rangefinders are used in many modern applications, from terrain mapping to biometric identification. Although a wide variety of designs have been proposed, laser speckle noise still provides a fundamental limitation on range accuracy. These works propose a new triangulation laser rangefinder designed specifically to mitigate the effects of laser speckle noise. The proposed rangefinder uses a precision linear translator to laterally reposition the imaging system (e.g., image sensor and imaging lens). For a given spatial location of the laser spot, capturing N spatially uncorrelated laser spot profiles is shown to improve range accuracy by a factor of N . This technique has many advantages over past speckle-reduction technologies, such as a fixed system cost and form factor, and the ability to virtually eliminate laser speckle noise. These advantages are made possible through spatial diversity and come at the cost of increased acquisition time. The rangefinder makes use of the ICFYKWG1 linear image sensor, a custom CMOS sensor developed at the Vision Sensor Laboratory (York University). Tests are performed on the image sensor's innovative high dynamic range technology to determine its effects on range accuracy. As expected, experimental results have shown that the sensor provides a trade-off between dynamic range and range accuracy.

  19. Estimation of suspended-sediment rating curves and mean suspended-sediment loads

    USGS Publications Warehouse

    Crawford, Charles G.

    1991-01-01

    A simulation study was done to evaluate: (1) the accuracy and precision of parameter estimates for the bias-corrected, transformed-linear and non-linear models obtained by the method of least squares; (2) the accuracy of mean suspended-sediment loads calculated by the flow-duration, rating-curve method using model parameters obtained by the alternative methods. Parameter estimates obtained by least squares for the bias-corrected, transformed-linear model were considerably more precise than those obtained for the non-linear or weighted non-linear model. The accuracy of parameter estimates obtained for the biascorrected, transformed-linear and weighted non-linear model was similar and was much greater than the accuracy obtained by non-linear least squares. The improved parameter estimates obtained by the biascorrected, transformed-linear or weighted non-linear model yield estimates of mean suspended-sediment load calculated by the flow-duration, rating-curve method that are more accurate and precise than those obtained for the non-linear model.

  20. Development, validation and evaluation of an analytical method for the determination of monomeric and oligomeric procyanidins in apple extracts.

    PubMed

    Hollands, Wendy J; Voorspoels, Stefan; Jacobs, Griet; Aaby, Kjersti; Meisland, Ane; Garcia-Villalba, Rocio; Tomas-Barberan, Francisco; Piskula, Mariusz K; Mawson, Deborah; Vovk, Irena; Needs, Paul W; Kroon, Paul A

    2017-04-28

    There is a lack of data for individual oligomeric procyanidins in apples and apple extracts. Our aim was to develop, validate and evaluate an analytical method for the separation, identification and quantification of monomeric and oligomeric flavanols in apple extracts. To achieve this, we prepared two types of flavanol extracts from freeze-dried apples; one was an epicatechin-rich extract containing ∼30% (w/w) monomeric (-)-epicatechin which also contained oligomeric procyanidins (Extract A), the second was an oligomeric procyanidin-rich extract depleted of epicatechin (Extract B). The parameters considered for method optimisation were HPLC columns and conditions, sample heating, mass of extract and dilution volumes. The performance characteristics considered for method validation included standard linearity, method sensitivity, precision and trueness. Eight laboratories participated in the method evaluation. Chromatographic separation of the analytes was best achieved utilizing a Hilic column with a binary mobile phase consisting of acidic acetonitrile and acidic aqueous methanol. The final method showed linearity for epicatechin in the range 5-100μg/mL with a correlation co-efficient >0.999. Intra-day and inter-day precision of the analytes ranged from 2 to 6% and 2 to 13% respectively. Up to dp3, trueness of the method was >95% but decreased with increasing dp. Within laboratory precision showed RSD values <5 and 10% for monomers and oligomers, respectively. Between laboratory precision was 4 and 15% (Extract A) and 7 and 30% (Extract B) for monomers and oligomers, respectively. An analytical method for the separation, identification and quantification of procyanidins in an apple extract was developed, validated and assessed. The results of the inter-laboratory evaluation indicate that the method is reliable and reproducible. Copyright © 2017. Published by Elsevier B.V.

  1. A low noise and high precision linear power supply with thermal foldback protection.

    PubMed

    Carniti, P; Cassina, L; Gotti, C; Maino, M; Pessina, G

    2016-05-01

    A low noise and high precision linear power supply was designed for use in rare event search experiments with macrobolometers. The circuit accepts at the input a "noisy" dual supply voltage up to ±15 V and gives at the output precise, low noise, and stable voltages that can be set between ±3.75 V and ±12.5 V in eight 1.25 V steps. Particular care in circuit design, component selection, and proper filtering results in a noise spectral density of 50nV/Hz at 1 Hz and 20nV/Hz white when the output is set to ±5 V. This corresponds to 125 nV RMS (0.8 μV peak to peak) between 0.1 Hz and 10 Hz, and 240 nV RMS (1.6 μV peak to peak) between 0.1 Hz and 100 Hz. The power supply rejection ratio (PSRR) of the circuit is 100 dB at low frequency, and larger than 40 dB up to high frequency, thanks to a proper compensation design. Calibration allows to reach a precision in the absolute value of the output voltage of ±70 ppm, or ±350 μV at ±5 V, and to reduce thermal drifts below ±1 ppm/(∘)C in the expected operating range. The maximum peak output current is about 6 A from each output. An original foldback protection scheme was developed that dynamically limits the maximum output current to keep the temperature of the output transistors within their safe operating range. An add-on card based on an ARM Cortex-M3 microcontroller is devoted to the monitoring and control of all circuit functionalities and provides remote communication via CAN bus.

  2. The Effects of Baseline Estimation on the Reliability, Validity, and Precision of CBM-R Growth Estimates

    ERIC Educational Resources Information Center

    Van Norman, Ethan R.; Christ, Theodore J.; Zopluoglu, Cengiz

    2013-01-01

    This study examined the effect of baseline estimation on the quality of trend estimates derived from Curriculum Based Measurement of Oral Reading (CBM-R) progress monitoring data. The authors used a linear mixed effects regression (LMER) model to simulate progress monitoring data for schedules ranging from 6-20 weeks for datasets with high and low…

  3. Development and validation of a HPTLC method for simultaneous estimation of lornoxicam and thiocolchicoside in combined dosage form

    PubMed Central

    Sahoo, Madhusmita; Syal, Pratima; Hable, Asawaree A.; Raut, Rahul P.; Choudhari, Vishnu P.; Kuchekar, Bhanudas S.

    2011-01-01

    Aim: To develop a simple, precise, rapid and accurate HPTLC method for the simultaneous estimation of Lornoxicam (LOR) and Thiocolchicoside (THIO) in bulk and pharmaceutical dosage forms. Materials and Methods: The separation of the active compounds from pharmaceutical dosage form was carried out using methanol:chloroform:water (9.6:0.2:0.2 v/v/v) as the mobile phase and no immiscibility issues were found. The densitometric scanning was carried out at 377 nm. The method was validated for linearity, accuracy, precision, LOD (Limit of Detection), LOQ (Limit of Quantification), robustness and specificity. Results: The Rf values (±SD) were found to be 0.84 ± 0.05 for LOR and 0.58 ± 0.05 for THIO. Linearity was obtained in the range of 60–360 ng/band for LOR and 30–180 ng/band for THIO with correlation coefficients r2 = 0.998 and 0.999, respectively. The percentage recovery for both the analytes was in the range of 98.7–101.2 %. Conclusion: The proposed method was optimized and validated as per the ICH guidelines. PMID:23781452

  4. UltraForm Finishing (UFF) a 5-axis computer controlled precision optical component grinding and polishing system

    NASA Astrophysics Data System (ADS)

    Bechtold, Michael; Mohring, David; Fess, Edward

    2007-05-01

    OptiPro Systems has developed a new finishing process for the manufacturing of precision optical components. UltraForm Finishing (UFF) has evolved from a tire shaped tool with polishing material on its periphery, to its newest design, which incorporates a precision rubber wheel wrapped with a band of polishing material passing over it. Through our research we have developed a user friendly graphical interface giving the optician a deterministic path for finishing precision optical components. Complex UFF Algorithms combine the removal function and desired depth of removal into a motion controlled tool path which minimizes surface roughness and form errors. The UFF process includes 5 axes of computer controlled motion, (3 linear and 2 rotary) which provide the flexibility for finishing a variety of shapes including spheres, aspheres, and freeform optics. The long arm extension, along with a range of diameters for the "UltraWheel" provides a unique solution for the finishing of steep concave shapes such as ogives and domes. The UltraForm process utilizes, fixed and loose abrasives, in combination with our proprietary "UltraBelts" made of a range of materials such as polyurethane, felt, resin, diamond and others.

  5. A high sensitive 66 dB linear dynamic range receiver for 3-D laser radar

    NASA Astrophysics Data System (ADS)

    Ma, Rui; Zheng, Hao; Zhu, Zhangming

    2017-08-01

    This study presents a CMOS receiver chip realized in 0.18 μm standard CMOS technology and intended for high precision 3-D laser radar. The chip includes an adjustable gain transimpedance pre-amplifier, a post-amplifier and two timing comparators. An additional feedback is employed in the regulated cascode transimpedance amplifier to decrease the input impedance, and a variable gain transimpedance amplifier controlled by digital switches and analog multiplexer is utilized to realize four gain modes, extending the input dynamic range. The measurement shows that the highest transimpedance of the channel is 50 k {{Ω }}, the uncompensated walk error is 1.44 ns in a wide linear dynamic range of 66 dB (1:2000), and the input referred noise current is 2.3 pA/\\sqrt{{Hz}} (rms), resulting in a very low detectable input current of 1 μA with SNR = 5.

  6. Amesos2 and Belos: Direct and Iterative Solvers for Large Sparse Linear Systems

    DOE PAGES

    Bavier, Eric; Hoemmen, Mark; Rajamanickam, Sivasankaran; ...

    2012-01-01

    Solvers for large sparse linear systems come in two categories: direct and iterative. Amesos2, a package in the Trilinos software project, provides direct methods, and Belos, another Trilinos package, provides iterative methods. Amesos2 offers a common interface to many different sparse matrix factorization codes, and can handle any implementation of sparse matrices and vectors, via an easy-to-extend C++ traits interface. It can also factor matrices whose entries have arbitrary “Scalar” type, enabling extended-precision and mixed-precision algorithms. Belos includes many different iterative methods for solving large sparse linear systems and least-squares problems. Unlike competing iterative solver libraries, Belos completely decouples themore » algorithms from the implementations of the underlying linear algebra objects. This lets Belos exploit the latest hardware without changes to the code. Belos favors algorithms that solve higher-level problems, such as multiple simultaneous linear systems and sequences of related linear systems, faster than standard algorithms. The package also supports extended-precision and mixed-precision algorithms. Together, Amesos2 and Belos form a complete suite of sparse linear solvers.« less

  7. Theoretically Guided Analytical Method Development and Validation for the Estimation of Rifampicin in a Mixture of Isoniazid and Pyrazinamide by UV Spectrophotometer

    PubMed Central

    Khan, Mohammad F.; Rita, Shamima A.; Kayser, Md. Shahidulla; Islam, Md. Shariful; Asad, Sharmeen; Bin Rashid, Ridwan; Bari, Md. Abdul; Rahman, Muhammed M.; Al Aman, D. A. Anwar; Setu, Nurul I.; Banoo, Rebecca; Rashid, Mohammad A.

    2017-01-01

    A simple, rapid, economic, accurate, and precise method for the estimation of rifampicin in a mixture of isoniazid and pyrazinamide by UV spectrophotometeric technique (guided by the theoretical investigation of physicochemical properties) was developed and validated. Theoretical investigations revealed that isoniazid and pyrazinamide both were freely soluble in water and slightly soluble in ethyl acetate whereas rifampicin was practically insoluble in water but freely soluble in ethyl acetate. This indicates that ethyl acetate is an effective solvent for the extraction of rifampicin from a water mixture of isoniazid and pyrazinamide. Computational study indicated that pH range of 6.0–8.0 would favor the extraction of rifampicin. Rifampicin is separated from isoniazid and pyrazinamide at pH 7.4 ± 0.1 by extracting with ethyl acetate. The ethyl acetate was then analyzed at λmax of 344.0 nm. The developed method was validated for linearity, accuracy and precision according to ICH guidelines. The proposed method exhibited good linearity over the concentration range of 2.5–35.0 μg/mL. The intraday and inter-day precision in terms of % RSD ranged from 1.09 to 1.70% and 1.63 to 2.99%, respectively. The accuracy (in terms of recovery) of the method varied from of 96.7 ± 0.9 to 101.1 ± 0.4%. The LOD and LOQ were found to be 0.83 and 2.52 μg/mL, respectively. In addition, the developed method was successfully applied to determine rifampicin combination (isoniazid and pyrazinamide) brands available in Bangladesh. PMID:28503547

  8. Theoretically Guided Analytical Method Development and Validation for the Estimation of Rifampicin in a Mixture of Isoniazid and Pyrazinamide by UV Spectrophotometer.

    PubMed

    Khan, Mohammad F; Rita, Shamima A; Kayser, Md Shahidulla; Islam, Md Shariful; Asad, Sharmeen; Bin Rashid, Ridwan; Bari, Md Abdul; Rahman, Muhammed M; Al Aman, D A Anwar; Setu, Nurul I; Banoo, Rebecca; Rashid, Mohammad A

    2017-01-01

    A simple, rapid, economic, accurate, and precise method for the estimation of rifampicin in a mixture of isoniazid and pyrazinamide by UV spectrophotometeric technique (guided by the theoretical investigation of physicochemical properties) was developed and validated. Theoretical investigations revealed that isoniazid and pyrazinamide both were freely soluble in water and slightly soluble in ethyl acetate whereas rifampicin was practically insoluble in water but freely soluble in ethyl acetate. This indicates that ethyl acetate is an effective solvent for the extraction of rifampicin from a water mixture of isoniazid and pyrazinamide. Computational study indicated that pH range of 6.0-8.0 would favor the extraction of rifampicin. Rifampicin is separated from isoniazid and pyrazinamide at pH 7.4 ± 0.1 by extracting with ethyl acetate. The ethyl acetate was then analyzed at λ max of 344.0 nm. The developed method was validated for linearity, accuracy and precision according to ICH guidelines. The proposed method exhibited good linearity over the concentration range of 2.5-35.0 μg/mL. The intraday and inter-day precision in terms of % RSD ranged from 1.09 to 1.70% and 1.63 to 2.99%, respectively. The accuracy (in terms of recovery) of the method varied from of 96.7 ± 0.9 to 101.1 ± 0.4%. The LOD and LOQ were found to be 0.83 and 2.52 μg/mL, respectively. In addition, the developed method was successfully applied to determine rifampicin combination (isoniazid and pyrazinamide) brands available in Bangladesh.

  9. Optimization and validation of liquid chromatography and headspace-gas chromatography based methods for the quantitative determination of capsaicinoids, salicylic acid, glycol monosalicylate, methyl salicylate, ethyl salicylate, camphor and l-menthol in a topical formulation.

    PubMed

    Pauwels, Jochen; D'Autry, Ward; Van den Bossche, Larissa; Dewever, Cédric; Forier, Michel; Vandenwaeyenberg, Stephanie; Wolfs, Kris; Hoogmartens, Jos; Van Schepdael, Ann; Adams, Erwin

    2012-02-23

    Capsaicinoids, salicylic acid, methyl and ethyl salicylate, glycol monosalicylate, camphor and l-menthol are widely used in topical formulations to relieve local pain. For each separate compound or simple mixtures, quantitative analysis methods are reported. However, for a mixture containing all above mentioned active compounds, no assay methods were found. Due to the differing physicochemical characteristics, two methods were developed and optimized simultaneously. The non-volatile capsaicinoids, salicylic acid and glycol monosalicylate were analyzed with liquid chromatography following liquid-liquid extraction, whereas the volatile compounds were analyzed with static headspace-gas chromatography. For the latter method, liquid paraffin was selected as compatible dilution solvent. The optimized methods were validated in terms of specificity, linearity, accuracy and precision in a range of 80% to 120% of the expected concentrations. For both methods, peaks were well separated without interference of other compounds. Linear relationships were demonstrated with R² values higher than 0.996 for all compounds. Accuracy was assessed by performing replicate recovery experiments with spiked blank samples. Mean recovery values were all between 98% and 102%. Precision was checked at three levels: system repeatability, method precision and intermediate precision. Both methods were found to be acceptably precise at all three levels. Finally, the method was successfully applied to the analysis of some real samples (cutaneous sticks). Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Simultaneous determination of four neuroprotective compounds of Tilia amurensis by high performance liquid chromatography coupled with diode array detector

    PubMed Central

    Lee, Bohyung; Weon, Jin Bae; Yun, Bo-Ra; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je

    2014-01-01

    Background: Tilia amurensis consists of various compounds, such as flavonoids and terpenoids. Objective: A simple and reliable high performance liquid chromatography (HPLC) coupled with the diode array detector (DAD) method has been established for simultaneous determination of epicatechin, nudiposide, lyoniside, and scopoletin isolated from Tilia amurensis. Materials and Methods: Optimum separations were obtained with a SHISEIDO C18 column by gradient eluton, with 0.1% Trifluoroacetic acid (TFA) water-methanol as the mobile phase. The gradient elution system was completed within 40 minutes. The flow rate and detection wavelength were 1 mL/minute, 205 nm, 250 nm, and 280 nm, respectively. Results: Validation of the analytical method was evaluated by linearity, precision, and the accuracy test. The calibration curve was linear over the established range with R2 > 0.997. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.01-15.20 μg/mL and 0.03-46.06 μg/mL. The method exhibited an intraday and interday precision range of 96.25-105.66% and 93.52-109.92%, respectively (RSD <2.80%). The recoveries and relative standard deviation (RSD) of the four compounds in Tilia amurensis were in the range of 90.42-104.84% and 0.2-2.58%. Conclusion: This developed method was accurate and reliable for the quality evaluation of the four compounds isolated from Tilia amurensis. PMID:25210303

  11. On the linear relation between the mean and the standard deviation of a response time distribution.

    PubMed

    Wagenmakers, Eric-Jan; Brown, Scott

    2007-07-01

    Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different experimental paradigms support a linear relation between RT mean and RT standard deviation. Both R. Ratcliff's (1978) diffusion model and G. D. Logan's (1988) instance theory of automatization provide explanations for this linear relation. The authors identify and discuss 3 specific boundary conditions for the linear law to hold. The law constrains RT models and supports the use of the coefficient of variation to (a) compare variability while controlling for differences in baseline speed of processing and (b) assess whether changes in performance with practice are due to quantitative speedup or qualitative reorganization. Copyright 2007 APA.

  12. Cumulative Retrospective Exposure Assessment (REA) as a predictor of amphibole asbestos lung burden: validation procedures and results for industrial hygiene and pathology estimates.

    PubMed

    Rasmuson, James O; Roggli, Victor L; Boelter, Fred W; Rasmuson, Eric J; Redinger, Charles F

    2014-01-01

    A detailed evaluation of the correlation and linearity of industrial hygiene retrospective exposure assessment (REA) for cumulative asbestos exposure with asbestos lung burden analysis (LBA) has not been previously performed, but both methods are utilized for case-control and cohort studies and other applications such as setting occupational exposure limits. (a) To correlate REA with asbestos LBA for a large number of cases from varied industries and exposure scenarios; (b) to evaluate the linearity, precision, and applicability of both industrial hygiene exposure reconstruction and LBA; and (c) to demonstrate validation methods for REA. A panel of four experienced industrial hygiene raters independently estimated the cumulative asbestos exposure for 363 cases with limited exposure details in which asbestos LBA had been independently determined. LBA for asbestos bodies was performed by a pathologist by both light microscopy and scanning electron microscopy (SEM) and free asbestos fibers by SEM. Precision, reliability, correlation and linearity were evaluated via intraclass correlation, regression analysis and analysis of covariance. Plaintiff's answers to interrogatories, work history sheets, work summaries or plaintiff's discovery depositions that were obtained in court cases involving asbestos were utilized by the pathologist to provide a summarized brief asbestos exposure and work history for each of the 363 cases. Linear relationships between REA and LBA were found when adjustment was made for asbestos fiber-type exposure differences. Significant correlation between REA and LBA was found with amphibole asbestos lung burden and mixed fiber-types, but not with chrysotile. The intraclass correlation coefficients (ICC) for the precision of the industrial hygiene rater cumulative asbestos exposure estimates and the precision of repeated laboratory analysis were found to be in the excellent range. The ICC estimates were performed independent of specific asbestos fiber-type. Both REA and pathology assessment are reliable and complementary predictive methods to characterize asbestos exposures. Correlation analysis between the two methods effectively validates both REA methodology and LBA procedures within the determined precision, particularly for cumulative amphibole asbestos exposures since chrysotile fibers, for the most part, are not retained in the lung for an extended period of time.

  13. Lawrence Livermore National Laboratory ULTRA-350 Test Bed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopkins, D J; Wulff, T A; Carlisle, K

    2001-04-10

    LLNL has many in-house designed high precision machine tools. Some of these tools include the Large Optics Diamond Turning Machine (LODTM) [1], Diamond Turning Machine No.3 (DTM-3) and two Precision Engineering Research Lathes (PERL-1 and PERL-11). These machines have accuracy in the sub-micron range and in most cases position resolution in the couple of nanometers range. All of these machines are built with similar underlying technologies. The machines use capstan drive technology, laser interferometer position feedback, tachometer velocity feedback, permanent magnet (PM) brush motors and analog velocity and position loop servo compensation [2]. The machine controller does not perform anymore » servo compensation it simply computes the differences between the commanded position and the actual position (the following error) and sends this to a D/A for the analog servo position loop. LLNL is designing a new high precision diamond turning machine. The machine is called the ULTRA 350 [3]. In contrast to many of the proven technologies discussed above, the plan for the new machine is to use brushless linear motors, high precision linear scales, machine controller motor commutation and digital servo compensation for the velocity and position loops. Although none of these technologies are new and have been in use in industry, applications of these technologies to high precision diamond turning is limited. To minimize the risks of these technologies in the new machine design, LLNL has established a test bed to evaluate these technologies for application in high precision diamond turning. The test bed is primarily composed of commercially available components. This includes the slide with opposed hydrostatic bearings, the oil system, the brushless PM linear motor, the two-phase input three-phase output linear motor amplifier and the system controller. The linear scales are not yet commercially available but use a common electronic output format. As of this writing, the final verdict for the use of these technologies is still out but the first part of the work has been completed with promising results. The goal of this part of the work was to close a servo position loop around a slide incorporating these technologies and to measure the performance. This paper discusses the tests that were setup for system evaluation and the results of the measurements made. Some very promising results include; slide positioning to nanometer level and slow speed slide direction reversal at less than 100nm/min with no observed discontinuities. This is very important for machine contouring in diamond turning. As a point of reference, at 100 nm/min it would take the slide almost 7 years to complete the full designed travel of 350 mm. This speed has been demonstrated without the use of a velocity sensor. The velocity is derived from the position sensor. With what has been learned on the test bed, the paper finishes with a brief comparison of the old and new technologies. The emphasis of this comparison will be on the servo performance as illustrated with bode plot diagrams.« less

  14. Lawrence Livermore National Laboratory ULTRA-350 Test Bed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopkins, D J; Wulff, T A; Carlisle, K

    2001-04-10

    LLNL has many in-house designed high precision machine tools. Some of these tools include the Large Optics Diamond Turning Machine (LODTM) [1], Diamond Turning Machine No.3 (DTM-3) and two Precision Engineering Research Lathes (PERL-I and PERL-II). These machines have accuracy in the sub-micron range and in most cases position resolution in the couple of nanometers range. All of these machines are built with similar underlying technologies. The machines use capstan drive technology, laser interferometer position feedback, tachometer velocity feedback, permanent magnet (PM) brush motors and analog velocity and position loop servo compensation [2]. The machine controller does not perform anymore » servo compensation it simply computes the differences between the commanded position and the actual position (the following error) and sends this to a D/A for the analog servo position loop. LLNL is designing a new high precision diamond turning machine. The machine is called the ULTRA 350 [3]. In contrast to many of the proven technologies discussed above, the plan for the new machine is to use brushless linear motors, high precision linear scales, machine controller motor commutation and digital servo compensation for the velocity and position loops. Although none of these technologies are new and have been in use in industry, applications of these technologies to high precision diamond turning is limited. To minimize the risks of these technologies in the new machine design, LLNL has established a test bed to evaluate these technologies for application in high precision diamond turning. The test bed is primarily composed of commercially available components. This includes the slide with opposed hydrostatic bearings, the oil system, the brushless PM linear motor, the two-phase input three-phase output linear motor amplifier and the system controller. The linear scales are not yet commercially available but use a common electronic output format. As of this writing, the final verdict for the use of these technologies is still out but the first part of the work has been completed with promising results. The goal of this part of the work was to close a servo position loop around a slide incorporating these technologies and to measure the performance. This paper discusses the tests that were setup for system evaluation and the results of the measurements made. Some very promising results include; slide positioning to nanometer level and slow speed slide direction reversal at less than 100nm/min with no observed discontinuities. This is very important for machine contouring in diamond turning. As a point of reference, at 100 nm/min it would take the slide almost 7 years to complete the full designed travel of 350 mm. This speed has been demonstrated without the use of a velocity sensor. The velocity is derived from the position sensor. With what has been learned on the test bed, the paper finishes with a brief comparison of the old and new technologies. The emphasis of this comparison will be on the servo performance as illustrated with bode plot diagrams.« less

  15. Interlaboratory comparability, bias, and precision for four laboratories measuring constituents in precipitation, November 1982-August 1983

    USGS Publications Warehouse

    Brooks, M.H.; Schroder, L.J.; Malo, B.A.

    1985-01-01

    Four laboratories were evaluated in their analysis of identical natural and simulated precipitation water samples. Interlaboratory comparability was evaluated using analysis of variance coupled with Duncan 's multiple range test, and linear-regression models describing the relations between individual laboratory analytical results for natural precipitation samples. Results of the statistical analyses indicate that certain pairs of laboratories produce different results when analyzing identical samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple range test on data produced by the laboratories from the analysis of identical simulated precipitation samples. Bias for a given analyte produced by a single laboratory has been indicated when the laboratory mean for that analyte is shown to be significantly different from the mean for the most-probable analyte concentrations in the simulated precipitation samples. Ion-chromatographic methods for the determination of chloride, nitrate, and sulfate have been compared with the colorimetric methods that were also in use during the study period. Comparisons were made using analysis of variance coupled with Duncan 's multiple range test for means produced by the two methods. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Analyte estimated precisions have been compared using F-tests and differences in analyte precisions for laboratory pairs have been reported. (USGS)

  16. Development and Validation of High-performance Thin Layer Chromatographic Method for Ursolic Acid in Malus domestica Peel

    PubMed Central

    Nikam, P. H.; Kareparamban, J. A.; Jadhav, A. P.; Kadam, V. J.

    2013-01-01

    Ursolic acid, a pentacyclic triterpenoid possess a wide range of pharmacological activities. It shows hypoglycemic, antiandrogenic, antibacterial, antiinflammatory, antioxidant, diuretic and cynogenic activity. It is commonly present in plants especially coating of leaves and fruits, such as apple fruit, vinca leaves, rosemary leaves, and eucalyptus leaves. A simple high-performance thin layer chromatographic method has been developed for the quantification of ursolic acid from apple peel (Malus domestica). The samples dissolved in methanol and linear ascending development was carried out in twin trough glass chamber. The mobile phase was selected as toluene:ethyl acetate:glacial acetic acid (70:30:2). The linear regression analysis data for the calibration plots showed good linear relationship with r2=0.9982 in the concentration range 0.2-7 μg/spot with respect to peak area. According to the ICH guidelines the method was validated for linearity, accuracy, precision, and robustness. Statistical analysis of the data showed that the method is reproducible and selective for the estimation of ursolic acid. PMID:24302805

  17. Higgs physics at the CLIC electron-positron linear collider.

    PubMed

    Abramowicz, H; Abusleme, A; Afanaciev, K; Alipour Tehrani, N; Balázs, C; Benhammou, Y; Benoit, M; Bilki, B; Blaising, J-J; Boland, M J; Boronat, M; Borysov, O; Božović-Jelisavčić, I; Buckland, M; Bugiel, S; Burrows, P N; Charles, T K; Daniluk, W; Dannheim, D; Dasgupta, R; Demarteau, M; Díaz Gutierrez, M A; Eigen, G; Elsener, K; Felzmann, U; Firlej, M; Firu, E; Fiutowski, T; Fuster, J; Gabriel, M; Gaede, F; García, I; Ghenescu, V; Goldstein, J; Green, S; Grefe, C; Hauschild, M; Hawkes, C; Hynds, D; Idzik, M; Kačarević, G; Kalinowski, J; Kananov, S; Klempt, W; Kopec, M; Krawczyk, M; Krupa, B; Kucharczyk, M; Kulis, S; Laštovička, T; Lesiak, T; Levy, A; Levy, I; Linssen, L; Lukić, S; Maier, A A; Makarenko, V; Marshall, J S; Martin, V J; Mei, K; Milutinović-Dumbelović, G; Moroń, J; Moszczyński, A; Moya, D; Münker, R M; Münnich, A; Neagu, A T; Nikiforou, N; Nikolopoulos, K; Nürnberg, A; Pandurović, M; Pawlik, B; Perez Codina, E; Peric, I; Petric, M; Pitters, F; Poss, S G; Preda, T; Protopopescu, D; Rassool, R; Redford, S; Repond, J; Robson, A; Roloff, P; Ros, E; Rosenblat, O; Ruiz-Jimeno, A; Sailer, A; Schlatter, D; Schulte, D; Shumeiko, N; Sicking, E; Simon, F; Simoniello, R; Sopicki, P; Stapnes, S; Ström, R; Strube, J; Świentek, K P; Szalay, M; Tesař, M; Thomson, M A; Trenado, J; Uggerhøj, U I; van der Kolk, N; van der Kraaij, E; Vicente Barreto Pinto, M; Vila, I; Vogel Gonzalez, M; Vos, M; Vossebeld, J; Watson, M; Watson, N; Weber, M A; Weerts, H; Wells, J D; Weuste, L; Winter, A; Wojtoń, T; Xia, L; Xu, B; Żarnecki, A F; Zawiejski, L; Zgura, I-S

    2017-01-01

    The Compact Linear Collider (CLIC) is an option for a future [Formula: see text] collider operating at centre-of-mass energies up to [Formula: see text], providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages: [Formula: see text], 1.4 and [Formula: see text]. The initial stage of operation allows the study of Higgs boson production in Higgsstrahlung ([Formula: see text]) and [Formula: see text]-fusion ([Formula: see text]), resulting in precise measurements of the production cross sections, the Higgs total decay width [Formula: see text], and model-independent determinations of the Higgs couplings. Operation at [Formula: see text] provides high-statistics samples of Higgs bosons produced through [Formula: see text]-fusion, enabling tight constraints on the Higgs boson couplings. Studies of the rarer processes [Formula: see text] and [Formula: see text] allow measurements of the top Yukawa coupling and the Higgs boson self-coupling. This paper presents detailed studies of the precision achievable with Higgs measurements at CLIC and describes the interpretation of these measurements in a global fit.

  18. Novel linear piezoelectric motor for precision position stage

    NASA Astrophysics Data System (ADS)

    Chen, Chao; Shi, Yunlai; Zhang, Jun; Wang, Junshan

    2016-03-01

    Conventional servomotor and stepping motor face challenges in nanometer positioning stages due to the complex structure, motion transformation mechanism, and slow dynamic response, especially directly driven by linear motor. A new butterfly-shaped linear piezoelectric motor for linear motion is presented. A two-degree precision position stage driven by the proposed linear ultrasonic motor possesses a simple and compact configuration, which makes the system obtain shorter driving chain. Firstly, the working principle of the linear ultrasonic motor is analyzed. The oscillation orbits of two driving feet on the stator are produced successively by using the anti-symmetric and symmetric vibration modes of the piezoelectric composite structure, and the slider pressed on the driving feet can be propelled twice in only one vibration cycle. Then with the derivation of the dynamic equation of the piezoelectric actuator and transient response model, start-upstart-up and settling state characteristics of the proposed linear actuator is investigated theoretically and experimentally, and is applicable to evaluate step resolution of the precision platform driven by the actuator. Moreover the structure of the two-degree position stage system is described and a special precision displacement measurement system is built. Finally, the characteristics of the two-degree position stage are studied. In the closed-loop condition the positioning accuracy of plus or minus <0.5 μm is experimentally obtained for the stage propelled by the piezoelectric motor. A precision position stage based the proposed butterfly-shaped linear piezoelectric is theoretically and experimentally investigated.

  19. A new capacitive long-range displacement nanometer sensor with differential sensing structure based on time-grating

    NASA Astrophysics Data System (ADS)

    Yu, Zhicheng; Peng, Kai; Liu, Xiaokang; Pu, Hongji; Chen, Ziran

    2018-05-01

    High-precision displacement sensors, which can measure large displacements with nanometer resolution, are key components in many ultra-precision fabrication machines. In this paper, a new capacitive nanometer displacement sensor with differential sensing structure is proposed for long-range linear displacement measurements based on an approach denoted time grating. Analytical models established using electric field coupling theory and an area integral method indicate that common-mode interference will result in a first-harmonic error in the measurement results. To reduce the common-mode interference, the proposed sensor design employs a differential sensing structure, which adopts a second group of induction electrodes spatially separated from the first group of induction electrodes by a half-pitch length. Experimental results based on a prototype sensor demonstrate that the measurement accuracy and the stability of the sensor are substantially improved after adopting the differential sensing structure. Finally, a prototype sensor achieves a measurement accuracy of  ±200 nm over the full 200 mm measurement range of the sensor.

  20. Linearity, Bias, and Precision of Hepatic Proton Density Fat Fraction Measurements by Using MR Imaging: A Meta-Analysis.

    PubMed

    Yokoo, Takeshi; Serai, Suraj D; Pirasteh, Ali; Bashir, Mustafa R; Hamilton, Gavin; Hernando, Diego; Hu, Houchun H; Hetterich, Holger; Kühn, Jens-Peter; Kukuk, Guido M; Loomba, Rohit; Middleton, Michael S; Obuchowski, Nancy A; Song, Ji Soo; Tang, An; Wu, Xinhuai; Reeder, Scott B; Sirlin, Claude B

    2018-02-01

    Purpose To determine the linearity, bias, and precision of hepatic proton density fat fraction (PDFF) measurements by using magnetic resonance (MR) imaging across different field strengths, imager manufacturers, and reconstruction methods. Materials and Methods This meta-analysis was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A systematic literature search identified studies that evaluated the linearity and/or bias of hepatic PDFF measurements by using MR imaging (hereafter, MR imaging-PDFF) against PDFF measurements by using colocalized MR spectroscopy (hereafter, MR spectroscopy-PDFF) or the precision of MR imaging-PDFF. The quality of each study was evaluated by using the Quality Assessment of Studies of Diagnostic Accuracy 2 tool. De-identified original data sets from the selected studies were pooled. Linearity was evaluated by using linear regression between MR imaging-PDFF and MR spectroscopy-PDFF measurements. Bias, defined as the mean difference between MR imaging-PDFF and MR spectroscopy-PDFF measurements, was evaluated by using Bland-Altman analysis. Precision, defined as the agreement between repeated MR imaging-PDFF measurements, was evaluated by using a linear mixed-effects model, with field strength, imager manufacturer, reconstruction method, and region of interest as random effects. Results Twenty-three studies (1679 participants) were selected for linearity and bias analyses and 11 studies (425 participants) were selected for precision analyses. MR imaging-PDFF was linear with MR spectroscopy-PDFF (R 2 = 0.96). Regression slope (0.97; P < .001) and mean Bland-Altman bias (-0.13%; 95% limits of agreement: -3.95%, 3.40%) indicated minimal underestimation by using MR imaging-PDFF. MR imaging-PDFF was precise at the region-of-interest level, with repeatability and reproducibility coefficients of 2.99% and 4.12%, respectively. Field strength, imager manufacturer, and reconstruction method each had minimal effects on reproducibility. Conclusion MR imaging-PDFF has excellent linearity, bias, and precision across different field strengths, imager manufacturers, and reconstruction methods. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on October 2, 2017.

  1. Simultaneous determination of some cholesterol-lowering drugs in their binary mixture by novel spectrophotometric methods

    NASA Astrophysics Data System (ADS)

    Lotfy, Hayam Mahmoud; Hegazy, Maha Abdel Monem

    2013-09-01

    Four simple, specific, accurate and precise spectrophotometric methods manipulating ratio spectra were developed and validated for simultaneous determination of simvastatin (SM) and ezetimibe (EZ) namely; extended ratio subtraction (EXRSM), simultaneous ratio subtraction (SRSM), ratio difference (RDSM) and absorption factor (AFM). The proposed spectrophotometric procedures do not require any preliminary separation step. The accuracy, precision and linearity ranges of the proposed methods were determined, and the methods were validated and the specificity was assessed by analyzing synthetic mixtures containing the cited drugs. The four methods were applied for the determination of the cited drugs in tablets and the obtained results were statistically compared with each other and with those of a reported HPLC method. The comparison showed that there is no significant difference between the proposed methods and the reported method regarding both accuracy and precision.

  2. Low-Amplitude Topographic Features and Textures on the Moon: Initial Results from Detrended Lunar Orbiter Laser Altimeter (LOLA) Topography

    NASA Technical Reports Server (NTRS)

    Kreslavsky, Mikhail A.; Head, James W.; Neumann, Gregory A.; Zuber, Maria T.; Smith, David E.

    2016-01-01

    Global lunar topographic data derived from ranging measurements by the Lunar Orbiter Laser Altimeter (LOLA) onboard LRO mission to the Moon have extremely high vertical precision. We use detrended topography as a means for utilization of this precision in geomorphological analysis. The detrended topography was calculated as a difference between actual topography and a trend surface defined as a median topography in a circular sliding window. We found that despite complicated distortions caused by the non-linear nature of the detrending procedure, visual inspection of these data facilitates identification of low-amplitude gently-sloping geomorphic features. We present specific examples of patterns of lava flows forming the lunar maria and revealing compound flow fields, a new class of lava flow complex on the Moon. We also highlight the identification of linear tectonic features that otherwise are obscured in the images and topographic data processed in a more traditional manner.

  3. Development and Validation of an HPLC Method for Karanjin in Pongamia pinnata linn. Leaves.

    PubMed

    Katekhaye, S; Kale, M S; Laddha, K S

    2012-01-01

    A rapid, simple and specific reversed-phase HPLC method has been developed for analysis of karanjin in Pongamia pinnata Linn. leaves. HPLC analysis was performed on a C(18) column using an 85:13.5:1.5 (v/v) mixtures of methanol, water and acetic acid as isocratic mobile phase at a flow rate of 1 ml/min. UV detection was at 300 nm. The method was validated for accuracy, precision, linearity, specificity. Validation revealed the method is specific, accurate, precise, reliable and reproducible. Good linear correlation coefficients (r(2)>0.997) were obtained for calibration plots in the ranges tested. Limit of detection was 4.35 μg and limit of quantification was 16.56 μg. Intra and inter-day RSD of retention times and peak areas was less than 1.24% and recovery was between 95.05 and 101.05%. The established HPLC method is appropriate enabling efficient quantitative analysis of karanjin in Pongamia pinnata leaves.

  4. Development and Validation of an HPLC Method for Karanjin in Pongamia pinnata linn. Leaves

    PubMed Central

    Katekhaye, S; Kale, M. S.; Laddha, K. S.

    2012-01-01

    A rapid, simple and specific reversed-phase HPLC method has been developed for analysis of karanjin in Pongamia pinnata Linn. leaves. HPLC analysis was performed on a C18 column using an 85:13.5:1.5 (v/v) mixtures of methanol, water and acetic acid as isocratic mobile phase at a flow rate of 1 ml/min. UV detection was at 300 nm. The method was validated for accuracy, precision, linearity, specificity. Validation revealed the method is specific, accurate, precise, reliable and reproducible. Good linear correlation coefficients (r2>0.997) were obtained for calibration plots in the ranges tested. Limit of detection was 4.35 μg and limit of quantification was 16.56 μg. Intra and inter-day RSD of retention times and peak areas was less than 1.24% and recovery was between 95.05 and 101.05%. The established HPLC method is appropriate enabling efficient quantitative analysis of karanjin in Pongamia pinnata leaves. PMID:23204626

  5. Development and Validation of RP-LC Method for the Determination of Cinnarizine/Piracetam and Cinnarizine/Heptaminol Acefyllinate in Presence of Cinnarizine Reported Degradation Products

    PubMed Central

    EL-Houssini, Ola M.; Zawilla, Nagwan H.; Mohammad, Mohammad A.

    2013-01-01

    Specific stability indicating reverse-phase liquid chromatography (RP-LC) assay method (SIAM) was developed for the determination of cinnarizine (Cinn)/piracetam (Pira) and cinnarizine (Cinn)/heptaminol acefyllinate (Hept) in the presence of the reported degradation products of Cinn. A C18 column and gradient mobile phase was applied for good resolution of all peaks. The detection was achieved at 210 nm and 254 nm for Cinn/Pira and Cinn/Hept, respectively. The responses were linear over concentration ranges of 20–200, 20–1000 and 25–1000 μgmL−1 for Cinn, Pira, and Hept respectively. The proposed method was validated for linearity, accuracy, repeatability, intermediate precision, and robustness via statistical analysis of the data. The method was shown to be precise, accurate, reproducible, sensitive, and selective for the analysis of Cinn/Pira and Cinn/Hept in laboratory prepared mixtures and in pharmaceutical formulations. PMID:24137049

  6. 5-HMF and carbohydrates content in stingless bee honey by CE before and after thermal treatment.

    PubMed

    Biluca, Fabíola C; Della Betta, Fabiana; de Oliveira, Gabriela Pirassol; Pereira, Lais Morilla; Gonzaga, Luciano Valdemiro; Costa, Ana Carolina Oliveira; Fett, Roseane

    2014-09-15

    This study aimed to assess 5-hydroximethylfurfural and carbohydrates (fructose, glucose, and sucrose) in 13 stingless bee honey samples before and after thermal treatment using a capillary electrophoresis method. The methods were validated for the parameters of linearity, matrix effects, precision, and accuracy. A factorial design was implemented to determine optimal thermal treatment conditions and then verify the postprocedural 5-HMF formation, but once 5-HMF were

  7. Determination of the neuropharmacological drug nodakenin in rat plasma and brain tissues by liquid chromatography tandem mass spectrometry: Application to pharmacokinetic studies.

    PubMed

    Song, Yingshi; Yan, Huiyu; Xu, Jingbo; Ma, Hongxi

    2017-09-01

    A rapid and sensitive liquid chromatography tandem mass spectrometry detection using selected reaction monitoring in positive ionization mode was developed and validated for the quantification of nodakenin in rat plasma and brain. Pareruptorin A was used as internal standard. A single step liquid-liquid extraction was used for plasma and brain sample preparation. The method was validated with respect to selectivity, precision, accuracy, linearity, limit of quantification, recovery, matrix effect and stability. Lower limit of quantification of nodakenin was 2.0 ng/mL in plasma and brain tissue homogenates. Linear calibration curves were obtained over concentration ranges of 2.0-1000 ng/mL in plasma and brain tissue homogenates for nodakenin. Intra-day and inter-day precisions (relative standard deviation, RSD) were <15% in both biological media. This assay was successfully applied to plasma and brain pharmacokinetic studies of nodakenin in rats after intravenous administration. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Experimental demonstration of deep frequency modulation interferometry.

    PubMed

    Isleif, Katharina-Sophie; Gerberding, Oliver; Schwarze, Thomas S; Mehmet, Moritz; Heinzel, Gerhard; Cervantes, Felipe Guzmán

    2016-01-25

    Experiments for space and ground-based gravitational wave detectors often require a large dynamic range interferometric position readout of test masses with 1 pm/√Hz precision over long time scales. Heterodyne interferometer schemes that achieve such precisions are available, but they require complex optical set-ups, limiting their scalability for multiple channels. This article presents the first experimental results on deep frequency modulation interferometry, a new technique that combines sinusoidal laser frequency modulation in unequal arm length interferometers with a non-linear fit algorithm. We have tested the technique in a Michelson and a Mach-Zehnder Interferometer topology, respectively, demonstrated continuous phase tracking of a moving mirror and achieved a performance equivalent to a displacement sensitivity of 250 pm/Hz at 1 mHz between the phase measurements of two photodetectors monitoring the same optical signal. By performing time series fitting of the extracted interference signals, we measured that the linearity of the laser frequency modulation is on the order of 2% for the laser source used.

  9. Linear CCD attitude measurement system based on the identification of the auxiliary array CCD

    NASA Astrophysics Data System (ADS)

    Hu, Yinghui; Yuan, Feng; Li, Kai; Wang, Yan

    2015-10-01

    Object to the high precision flying target attitude measurement issues of a large space and large field of view, comparing existing measurement methods, the idea is proposed of using two array CCD to assist in identifying the three linear CCD with multi-cooperative target attitude measurement system, and to address the existing nonlinear system errors and calibration parameters and more problems with nine linear CCD spectroscopic test system of too complicated constraints among camera position caused by excessive. The mathematical model of binocular vision and three linear CCD test system are established, co-spot composition triangle utilize three red LED position light, three points' coordinates are given in advance by Cooperate Measuring Machine, the red LED in the composition of the three sides of a triangle adds three blue LED light points as an auxiliary, so that array CCD is easier to identify three red LED light points, and linear CCD camera is installed of a red filter to filter out the blue LED light points while reducing stray light. Using array CCD to measure the spot, identifying and calculating the spatial coordinates solutions of red LED light points, while utilizing linear CCD to measure three red LED spot for solving linear CCD test system, which can be drawn from 27 solution. Measured with array CCD coordinates auxiliary linear CCD has achieved spot identification, and has solved the difficult problems of multi-objective linear CCD identification. Unique combination of linear CCD imaging features, linear CCD special cylindrical lens system is developed using telecentric optical design, the energy center of the spot position in the depth range of convergence in the direction is perpendicular to the optical axis of the small changes ensuring highprecision image quality, and the entire test system improves spatial object attitude measurement speed and precision.

  10. The Performance of the Abbott i2000 for Measuring Serum Markers of Infectious Diseases.

    PubMed

    Wang, Linchuan; Chen, Wei; Yu, Yan

    2017-01-01

    To date, there is a trend that the chemiluminescent microparticle immunoassays (CMIA) and electrochemiluminescence immunoassays (ECIA) technology gradually replacing the enzyme-linked immunosorbent assay (ELISA). But the performance such as the limit of quantitation (LOQ), precision, linear range of CMIA, or ECIA for serum markers of infectious diseases has rarely been reported. Using proficiency testing samples and standard materials, we confirmed the LOQ of the ELISA and the precision, linear range, LOQ, and instrument biases of the Abbott i2000 for eight serum markers. We used the Abbott i2000 and ELISAs to assess five HIV samples; the researchers were blinded to the true status of the samples. For the Abbott i2000, the coefficients of variation (CV) for the low, medium, and high concentration samples ranged from 1.06 to 12.74%, which were less than the allowable error; the linear ranges of HBsAg and HBsAb were 0.66-304.11 IU/ml and 8.16-1205.9 mIU/ml, respectively. For the Abbott i2000, the LOQs of HBsAg, HBsAb, HBeAg, HBeAb, HBcAb, anti-HCV, anti-TP, and anti-HIV were 0.026 IU/ml, 4 mIU/ml, 0.14 NCU/ml, 0.56 NCU/ml, 0.99 NCU/ml, 0.5 NCU/ml, 8.8 mIU/ml, and 1.92 NCU/ml, respectively, and these values were 0.16 IU/ml, 6.97 mIU/ml, 1.16 NCU/ml, 1.63 NCU/ml, 1.79 NCU/ml, 1.03 NCU/ml, 8.33 mIU/ml, and 1.3 NCU/ml, respectively, for the ELISA. When five HIV samples were blindly assessed, two cases were missed by the Abbott i2000 and the ELISA results were consistent with the expected results. The Abbott i2000 performed significantly better than the ELISA on HBV and HCV screening; however, for anti-TP and anti-HIV, the ELISA remained the preferred method. © 2016 Wiley Periodicals, Inc.

  11. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident

    PubMed Central

    Semenova, Vera A.; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r2), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from −4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r2 = 0.952, slope = 1.02 and intercept = −0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. PMID:27814939

  12. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident.

    PubMed

    Semenova, Vera A; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r 2 ), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from -4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r 2  = 0.952, slope = 1.02 and intercept = -0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. Published by Elsevier Ltd.

  13. Validation of an assay for quantification of free normetanephrine, metanephrine and methoxytyramine in plasma by high performance liquid chromatography with coulometric detection: Comparison of peak-area vs. peak-height measurements.

    PubMed

    Nieć, Dawid; Kunicki, Paweł K

    2015-10-01

    Measurements of plasma concentrations of free normetanephrine (NMN), metanephrine (MN) and methoxytyramine (MTY) constitute the most diagnostically accurate screening test for pheochromocytomas and paragangliomas. The aim of this article is to present the results from a validation of an analytical method utilizing high performance liquid chromatography with coulometric detection (HPLC-CD) for quantifying plasma free NMN, MN and MTY. Additionally, peak integration by height and area and the use of one calibration curve for all batches or individual calibration curve for each batch of samples was explored as to determine the optimal approach with regard to accuracy and precision. The method was validated using charcoal stripped plasma spiked with solutions of NMN, MN, MTY and internal standard (4-hydroxy-3-methoxybenzylamine) with the exception of selectivity which was evaluated by analysis of real plasma samples. Calibration curve performance, accuracy, precision and recovery were determined following both peak-area and peak-height measurements and the obtained results were compared. The most accurate and precise method of calibration was evaluated by analyzing quality control samples at three concentration levels in 30 analytical runs. The detector response was linear over the entire tested concentration range from 10 to 2000pg/mL with R(2)≥0.9988. The LLOQ was 10pg/mL for each analyte of interest. To improve accuracy for measurements at low concentrations, a weighted (1/amount) linear regression model was employed, which resulted in inaccuracies of -2.48 to 9.78% and 0.22 to 7.81% following peak-area and peak-height integration, respectively. The imprecisions ranged from 1.07 to 15.45% and from 0.70 to 11.65% for peak-area and peak-height measurements, respectively. The optimal approach to calibration was the one utilizing an individual calibration curve for each batch of samples and peak-height measurements. It was characterized by inaccuracies ranging from -3.39 to +3.27% and imprecisions from 2.17 to 13.57%. The established HPLC-CD method enables accurate and precise measurements of plasma free NMN, MN and MTY with reasonable selectivity. Preparing calibration curve based on peak-height measurements for each batch of samples yields optimal accuracy and precision. Copyright © 2015. Published by Elsevier B.V.

  14. One novel type of miniaturization FBG rotation angle sensor with high measurement precision and temperature self-compensation

    NASA Astrophysics Data System (ADS)

    Jiang, Shanchao; Wang, Jing; Sui, Qingmei

    2018-03-01

    In order to achieve rotation angle measurement, one novel type of miniaturization fiber Bragg grating (FBG) rotation angle sensor with high measurement precision and temperature self-compensation is proposed and studied in this paper. The FBG rotation angle sensor mainly contains two core sensitivity elements (FBG1 and FBG2), triangular cantilever beam, and rotation angle transfer element. In theory, the proposed sensor can achieve temperature self-compensation by complementation of the two core sensitivity elements (FBG1 and FBG2), and it has a boundless angel measurement range with 2π rad period duo to the function of the rotation angle transfer element. Based on introducing the joint working processes, the theory calculation model of the FBG rotation angel sensor is established, and the calibration experiment on one prototype is also carried out to obtain its measurement performance. After experimental data analyses, the measurement precision of the FBG rotation angle sensor prototype is 0.2 ° with excellent linearity, and the temperature sensitivities of FBG1 and FBG2 are 10 pm/° and 10.1 pm/°, correspondingly. All these experimental results confirm that the FBG rotation angle sensor can achieve large-range angle measurement with high precision and temperature self-compensation.

  15. Precision tip-tilt-piston actuator that provides exact constraint

    DOEpatents

    Hale, Layton C.

    1999-01-01

    A precision device which can precisely actuate three degrees of freedom of an optic mount, commonly referred to as tip, tilt, and piston. The device consists of three identical flexure mechanisms, an optic mount to be supported and positioned, a structure that supports the flexure mechanisms, and three commercially available linear actuators. The advantages of the precision device is in the arrangement of the constraints offered by the flexure mechanism and not in the particular design of the flexure mechanisms, as other types of mechanisms could be substituted. Each flexure mechanism constrains two degrees of freedom in the plane of the mechanisms and one direction is actuated. All other degrees of freedom are free to move within the range of flexure mechanisms. Typically, three flexure mechanisms are equally spaced in angle about to optic mount and arranged so that each actuated degree of freedom is perpendicular to the plane formed by the optic mount. This arrangement exactly constrains the optic mount and allows arbitrary actuated movement of the plane within the range of the flexure mechanisms. Each flexure mechanism provides a mechanical advantage, typically on the order of 5:1, between the commercially available actuator and the functional point on the optic mount. This improves resolution by the same ratio and stiffness by the square of the ratio.

  16. Simultaneous determination of naringenin and hesperetin in rats after oral administration of Da-Cheng-Qi decoction by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Liu, Ying; Xu, Fengguo; Zhang, Zunjian; Song, Rui; Tian, Yuan

    2008-07-01

    To quantify naringenin and hesperetin in rat plasma after oral administration of Da-Cheng-Qi decoction, a famous purgative traditional Chinese medicine, a high-performance liquid chromatography-tandem mass spectrometry method was developed and validated. The HPLC separation was carried out on a Zorbax SB-C(18) column using 0.1% formic acid-methanol as mobile phase and estazolam as internal standard after the sample of rat plasma had been cleaned up with one-step protein precipitation using methanol. Atmospheric pressure chemical ionization in the positive ion mode and selected reaction monitoring method was developed to determine the active components. This method was validated in terms of recovery, linearity, accuracy and precision (intra- and inter-batch variation). The recoveries of naringenin and hesperetin were 72.8-76.6 and 75.7-77.2%, respectively. Linearity in rat plasma was observed over the range of 0.5-250 ng/mL (r2 > 0.99) for both naringenin and hesperetin. The accuracy and precision were well within the acceptable range and the relative standard deviation of the measured rat plasma samples was less than 15% (n = 5). The validated method was successfully applied for the evaluation of the pharmacokinetics of naringenin and hesperetin administered to six rats.

  17. Cytoplasmic dynein binding, run length, and velocity are guided by long-range electrostatic interactions

    PubMed Central

    Li, Lin; Alper, Joshua; Alexov, Emil

    2016-01-01

    Dyneins are important molecular motors involved in many essential biological processes, including cargo transport along microtubules, mitosis, and in cilia. Dynein motility involves the coupling of microtubule binding and unbinding to a change in the configuration of the linker domain induced by ATP hydrolysis, which occur some 25 nm apart. This leaves the accuracy of dynein stepping relatively inaccurate and susceptible to thermal noise. Using multi-scale modeling with a computational focusing technique, we demonstrate that the microtubule forms an electrostatic funnel that guides the dynein’s microtubule binding domain (MTBD) as it finally docks to the precise, keyed binding location on the microtubule. Furthermore, we demonstrate that electrostatic component of the MTBD’s binding free energy is linearly correlated with the velocity and run length of dynein, and we use this linearity to predict the effect of mutating each glutamic and aspartic acid located in MTBD domain to alanine. Lastly, we show that the binding of dynein to the microtubule is associated with conformational changes involving several helices, and we localize flexible hinge points within the stalk helices. Taken all together, we demonstrate that long range electrostatic interactions bring a level of precision to an otherwise noisy dynein stepping process. PMID:27531742

  18. Microbiological assay for the analysis of certain macrolides in pharmaceutical dosage forms.

    PubMed

    Mahmoudi, A; Fourar, R E-A; Boukhechem, M S; Zarkout, S

    2015-08-01

    Clarithromycin (CLA) and roxithromycin (ROX) are macrolide antibiotics with an expanded spectrum of activity that are commercially available as tablets. A microbiological assay, applying the cylinder-plate method and using a strain of Micrococcus luteus ATCC 9341 as test organism, has been used and validated for the quantification of two macrolide drugs; CLA and ROX in pure and pharmaceutical formulations. The validation of the proposed method was carried out for linearity, precision, accuracy and specificity. The linear dynamic ranges were from 0.1 to 0.5μg/mL for both compounds. Logarithmic calibration curve was obtained for each macrolide (r>0.989) with statistically equal slopes varying from 3.275 to 4.038, and a percentage relative standard deviation in the range of 0.24-0.92%. Moreover, the method was applied successfully for the assay of the studied drugs in pharmaceutical tablet dosage forms. Recovery from standard addition experiments in commercial products was 94.71-96.91% regarding clarithromycin and 93.94-98.12% regarding roxithromycin, with a precision (%RSD) 1.32-2.11%. Accordingly, this microbiological assay can be used for routine quality control analysis of titled drugs in tablet formulations. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. A sensitive and rapid determination of ranitidine in human plasma by HPLC with fluorescence detection and its application for a pharmacokinetic study.

    PubMed

    Ulu, Sevgi Tatar; Tuncel, Muzaffer

    2012-04-01

    A novel precolumn derivatization reversed-phase high-performance liquid chromatography method with fluorescence detection is described for the determination of ranitidine in human plasma. The method was based on the reaction of ranitidine with 4-fluoro-7-nitrobenzo-2-oxa-1,3-diazole forming yellow colored fluorescent product. The separation was achieved on a C(18) column using methanol-water (60:40, v/v) mobile phase. Fluorescence detection was used at the excitation and emission of 458 and 521 nm, respectively. Lisinopril was utilized as an internal standard. The flow rate was 1.2 mL/min. Ranitidine and lisinopril appeared at 3.24 and 2.25 min, respectively. The method was validated for system suitability, precision, accuracy, linearity, limit of detection, limit of quantification, recovery and robustness. Intra- and inter-day precisions of the assays were in the range of 0.01-0.44%. The assay was linear over the concentration range of 50-2000 ng/mL. The mean recovery was determined to be 96.40 ± 0.02%. This method was successfully applied to a pharmacokinetic study after oral administration of a dose (150 mg) of ranitidine. © The Author [2012]. Published by Oxford University Press. All rights reserved.

  20. Development and Analytical Validation of an Immunoassay for Quantifying Serum Anti-Pertussis Toxin Antibodies Resulting from Bordetella pertussis Infection ▿

    PubMed Central

    Menzies, Sandra L.; Kadwad, Vijay; Pawloski, Lucia C.; Lin, Tsai-Lien; Baughman, Andrew L.; Martin, Monte; Tondella, Maria Lucia C.; Meade, Bruce D.

    2009-01-01

    Adequately sensitive and specific methods to diagnose pertussis in adolescents and adults are not widely available. Currently, no Food and Drug Administration-approved diagnostic assays are available for the serodiagnosis of Bordetella pertussis. Since concentrations of B. pertussis-specific antibodies tend to be high during the later phases of disease, a simple, rapid, easily transferable serodiagnostic test was developed. This article describes test development, initial evaluation of a prototype kit enzyme-linked immunosorbent assay (ELISA) in an interlaboratory collaborative study, and analytical validation. The data presented here demonstrate that the kit met all prespecified criteria for precision, linearity, and accuracy for samples with anti-pertussis toxin (PT) immunoglobulin G (IgG) antibody concentrations in the range of 50 to 150 ELISA units (EU)/ml, the range believed to be most relevant for serodiagnosis. The assay met the precision and linearity criteria for a wider range, namely, from 50 to 200 EU/ml; however, the accuracy criterion was not met at 200 EU/ml. When the newly adopted World Health Organization International Standard for pertussis antiserum (human) reference reagent was used to evaluate accuracy, the accuracy criteria were met from 50 to 200 international units/ml. In conclusion, the IgG anti-PT ELISA met all assay validation parameters within the range considered most relevant for serodiagnosis. This ELISA was developed and analytically validated as a user-friendly kit that can be used in both qualitative and quantitative formats. The technology for producing the kit is transferable to public health laboratories. PMID:19864485

  1. Simultaneous determination of five major compounds in the traditional medicine Pyeongwee-San by high performance liquid chromatography-diode array detection and liquid chromatography-mass spectrometry/mass spectrometry.

    PubMed

    Lee, Bohyoung; Weon, Jin Bae; Yun, Bo-Ra; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je

    2014-01-01

    Pyeongwee-San (PWS) has been widely used for treating acute gastritis, chronic, and gastritis. In this paper, simultaneous determination of five compounds (naringin, hesperidin, glycyrrhizin, atractylenolide III, and magnolol) from traditional medicine PWS using the high performance liquid chromatography (HPLC) was established for quality control. Optimum separations were obtained with a SHISEIDO C18 reverse-phase column by gradient elution with 0.1% Trifluoroacetic acid (TFA) water-acetonitrile as the mobile phase. The flow rate was 1 mL/min and detection wavelength was set at 205 nm and 250 nm. Validation of the analytical method was evaluated by linearity, precision, and accuracy test. The calibration curves were linear over the established range with R (2) > 0.9978. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.09 to 0.43 and 0.27 to 1.29 μg/mL. The method exhibited intra-day and inter-day precision range between 0.01-1.86% and 0.04-0.35% respectively. The recoveries of five compounds in PWS were in the range between 93.18-106.40%, and 0.20-1.51%. The application of this method was identified through the successful analysis of five compounds in 12 batches of PWS. In addition, identification of five compounds was confirmed by a liquid chromatography method and mass spectrometry. The HPLC method was could be accomplished to the quality control and stable experiment for the preparations consisted of five major compounds.

  2. High-precision Ru isotopic measurements by multi-collector ICP-MS.

    PubMed

    Becker, Harry; Dalpe, Claude; Walker, Richard J

    2002-06-01

    Ruthenium isotopic data for a pure Aldrich ruthenium nitrate solution obtained using a Nu Plasma multi collector inductively coupled plasma-mass spectrometer (MC-ICP-MS) shows excellent agreement (better than 1 epsilon unit = 1 part in 10(4)) with data obtained by other techniques for the mass range between 96 and 101 amu. External precisions are at the 0.5-1.7 epsilon level (2sigma). Higher sensitivity for MC ICP-MS compared to negative thermal ionization mass spectrometry (N-TIMS) is offset by the uncertainties introduced by relatively large mass discrimination and instabilities in the plasma source-ion extraction region that affect the long-term reproducibility. Large mass bias correction in ICP mass spectrometry demands particular attention to be paid to the choice of normalizing isotopes. Because of its position in the mass spectrum and the large mass bias correction, obtaining precise and accurate abundance data for 104Ru by MC-ICP-MS remains difficult. Internal and external mass bias correction schemes in this mass range may show similar shortcomings if the isotope of interest does not lie within the mass range covered by the masses used for normalization. Analyses of meteorite samples show that if isobaric interferences from Mo are sufficiently large (Ru/Mo < 10(4)), uncertainties on the Mo interference correction propagate through the mass bias correction and yield inaccurate results for Ru isotopic compositions. Second-order linear corrections may be used to correct for these inaccuracies, but such results are generally less precise than N-TIMS data.

  3. High Precision Piezoelectric Linear Motors for Operations at Cryogenic Temperatures and Vacuum

    NASA Technical Reports Server (NTRS)

    Wong, D.; Carman, G.; Stam, M.; Bar-Cohen, Y.; Sen, A.; Henry, P.; Bearman, G.; Moacanin, J.

    1995-01-01

    The Jet Propulsion Laboratory evaluated the use of an electromechanical device for optically positioning a mirror system during the pre-project phase of the Pluto-Fast-Flyby (PFF) mission. The device under consideration was a piezoelectric driven linear motor functionally dependent upon a time varying electric field which induces displacements ranging from submicrons to millimeters with positioning accuracy within nanometers. Using a control package, the mirror system provides image motion compensation and mosaicking capabilities. While this device offers unique advantages, there were concerns pertaining to its operational capabilities for the PFF mission. The issues include irradiation effects and thermal concerns. A literature study indicated that irradiation effects will not significantly impact the linear motor's operational characteristics. On the other hand, thermal concerns necessitated an in depth study.

  4. Determining CDOM Absorption Spectra in Diverse Coastal Environments Using a Multiple Pathlength, Liquid Core Waveguide System. Measuring the Absorption of CDOM in the Field Using a Multiple Pathlength Liquid Waveguide System

    NASA Technical Reports Server (NTRS)

    Miller, Richard L.; Belz, Mathias; DelCastillo, Carlos; Trzaska, Rick

    2000-01-01

    We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, a(sub CDOM), and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values (r > 0.99) and showed a linear response across all four pathlengths. Values of a(sub CDOM) measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of a(sub CDOM) for MPLCW measurements was 0.002 - 231.5/m. At low CDOM concentrations (a(sub 370) < 0.1/m) spectrophotometric a(sub CDOM) were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples. The maximum deviation in replicate MPLCW spectra was less than 0.001 absorbance units. The portability, sampling, and optical characteristics of a MPLCW system provide significant enhancements for routine CDOM absorption measurements in a broad range of natural waters.

  5. A fast liquid chromatography-tandem mass spectrometry method for determining benzodiazepines and analogues in urine. Validation and application to real cases of forensic interest.

    PubMed

    Salomone, Alberto; Gerace, Enrico; Brizio, Paola; Gennaro, M Carla; Vincenti, Marco

    2011-11-01

    A fast liquid chromatographic/tandem mass spectrometric method was developed for the simultaneous determination in human urine of seventeen benzodiazepines, four relevant metabolites together plus zolpidem and zopiclone. The sample preparation, optimized to take into account the matrix effect, was based on enzymatic hydrolysis and liquid-liquid extraction. The separation of the twenty-three analytes was achieved in less than eight minutes. The whole methodology was fully validated according to UNI EN ISO/IEC 17025:2005 rules and 2006 SOFT/AAFS guidelines. Selectivity, linearity range, identification (LOD) and quantitation (LOQ) limits, precision, accuracy and recovery were evaluated. For all the species the signal/concentration linearity was satisfactory in the 50-1000 ng/mL concentration range. The limits of detection ranged from 0.5 to 30 ng/mL and LOQs from 1.7 to 100.0 ng/mL. Precisions were in the ranges 5.0-11.8%, 1.5-11.0% and 1.1-4.4% for low (100 ng/mL), medium (300 ng/mL) and high (1000 ng/mL) concentration, respectively. The accuracy, expressed as bias% was within ± 25 % for all the analytes. The recovery values, evaluated at 300 ng/mL concentration, ranged from 56.2% to 98.8%. The present method for the determination of several benzodiazepines, zolpidem and zopiclone in human urine proved to be simple, fast, specific and sensitive. The quantification by LC-MS/MS was successfully applied to 329 forensic cases among driving re-licensing, car accidents and alleged sexual violence cases. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Absolute GPS Positioning Using Genetic Algorithms

    NASA Astrophysics Data System (ADS)

    Ramillien, G.

    A new inverse approach for restoring the absolute coordinates of a ground -based station from three or four observed GPS pseudo-ranges is proposed. This stochastic method is based on simulations of natural evolution named genetic algorithms (GA). These iterative procedures provide fairly good and robust estimates of the absolute positions in the Earth's geocentric reference system. For comparison/validation, GA results are compared to the ones obtained using the classical linearized least-square scheme for the determination of the XYZ location proposed by Bancroft (1985) which is strongly limited by the number of available observations (i.e. here, the number of input pseudo-ranges must be four). The r.m.s. accuracy of the non -linear cost function reached by this latter method is typically ~10-4 m2 corresponding to ~300-500-m accuracies for each geocentric coordinate. However, GA can provide more acceptable solutions (r.m.s. errors < 10-5 m2), even when only three instantaneous pseudo-ranges are used, such as a lost of lock during a GPS survey. Tuned GA parameters used in different simulations are N=1000 starting individuals, as well as Pc=60-70% and Pm=30-40% for the crossover probability and mutation rate, respectively. Statistical tests on the ability of GA to recover acceptable coordinates in presence of important levels of noise are made simulating nearly 3000 random samples of erroneous pseudo-ranges. Here, two main sources of measurement errors are considered in the inversion: (1) typical satellite-clock errors and/or 300-metre variance atmospheric delays, and (2) Geometrical Dilution of Precision (GDOP) due to the particular GPS satellite configuration at the time of acquisition. Extracting valuable information and even from low-quality starting range observations, GA offer an interesting alternative for high -precision GPS positioning.

  7. Leaner and greener analysis of cannabinoids.

    PubMed

    Mudge, Elizabeth M; Murch, Susan J; Brown, Paula N

    2017-05-01

    There is an explosion in the number of labs analyzing cannabinoids in marijuana (Cannabis sativa L., Cannabaceae) but existing methods are inefficient, require expert analysts, and use large volumes of potentially environmentally damaging solvents. The objective of this work was to develop and validate an accurate method for analyzing cannabinoids in cannabis raw materials and finished products that is more efficient and uses fewer toxic solvents. An HPLC-DAD method was developed for eight cannabinoids in cannabis flowers and oils using a statistically guided optimization plan based on the principles of green chemistry. A single-laboratory validation determined the linearity, selectivity, accuracy, repeatability, intermediate precision, limit of detection, and limit of quantitation of the method. Amounts of individual cannabinoids above the limit of quantitation in the flowers ranged from 0.02 to 14.9% w/w, with repeatability ranging from 0.78 to 10.08% relative standard deviation. The intermediate precision determined using HorRat ratios ranged from 0.3 to 2.0. The LOQs for individual cannabinoids in flowers ranged from 0.02 to 0.17% w/w. This is a significant improvement over previous methods and is suitable for a wide range of applications including regulatory compliance, clinical studies, direct patient medical services, and commercial suppliers.

  8. Programmable Quantitative DNA Nanothermometers.

    PubMed

    Gareau, David; Desrosiers, Arnaud; Vallée-Bélisle, Alexis

    2016-07-13

    Developing molecules, switches, probes or nanomaterials that are able to respond to specific temperature changes should prove of utility for several applications in nanotechnology. Here, we describe bioinspired strategies to design DNA thermoswitches with programmable linear response ranges that can provide either a precise ultrasensitive response over a desired, small temperature interval (±0.05 °C) or an extended linear response over a wide temperature range (e.g., from 25 to 90 °C). Using structural modifications or inexpensive DNA stabilizers, we show that we can tune the transition midpoints of DNA thermometers from 30 to 85 °C. Using multimeric switch architectures, we are able to create ultrasensitive thermometers that display large quantitative fluorescence gains within small temperature variation (e.g., > 700% over 10 °C). Using a combination of thermoswitches of different stabilities or a mix of stabilizers of various strengths, we can create extended thermometers that respond linearly up to 50 °C in temperature range. Here, we demonstrate the reversibility, robustness, and efficiency of these programmable DNA thermometers by monitoring temperature change inside individual wells during polymerase chain reactions. We discuss the potential applications of these programmable DNA thermoswitches in various nanotechnology fields including cell imaging, nanofluidics, nanomedecine, nanoelectronics, nanomaterial, and synthetic biology.

  9. A robust LC-MS/MS method for the determination of pidotimod in different biological matrixes and its application to in vivo and in vitro pharmacokinetic studies.

    PubMed

    Wang, Guangji; Wang, Qian; Rao, Tai; Shen, Boyu; Kang, Dian; Shao, Yuhao; Xiao, Jingcheng; Chen, Huimin; Liang, Yan

    2016-06-15

    Pidotimod, (R)-3-[(S)-(5-oxo-2-pyrrolidinyl) carbonyl]-thiazolidine-4-carboxylic acid, was frequently used to treat children with recurrent respiratory infections. Preclinical pharmacokinetics of pidotimod was still rarely reported to date. Herein, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to determine pidotimod in rat plasma, tissue homogenate and Caco-2 cells. In this process, phenacetin was chosen as the internal standard due to its similarity in chromatographic and mass spectrographic characteristics with pidotimod. The plasma calibration curves were established within the concentration range of 0.01-10.00μg/mL, and similar linear curves were built using tissue homogenate and Caco-2 cells. The calibration curves for all biological samples showed good linearity (r>0.99) over the concentration ranges tested. The intra- and inter-day precision (RSD, %) values were below 15% and accuracy (RE, %) was ranged from -15% to 15% at all quality control levels. For plasma, tissue homogenate and Caco-2 cells, no obvious matrix effect was found, and the average recoveries were all above 75%. Thus, the method demonstrated excellent accuracy, precision and robustness for high throughput applications, and was then successfully applied to the studies of absorption in rat plasma, distribution in rat tissues and intracellular uptake characteristics in Caco-2 cells for pidotimod. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. A Wide Linearity Range Method for the Determination of Lenalidomide in Plasma by High-Performance Liquid Chromatography: Application to Pharmacokinetic Studies.

    PubMed

    Guglieri-López, Beatriz; Pérez-Pitarch, Alejandro; Martinez-Gómez, Maria Amparo; Porta-Oltra, Begoña; Climente-Martí, Mónica; Merino-Sanjuán, Matilde

    2016-12-01

    A wide linearity range analytical method for the determination of lenalidomide in patients with multiple myeloma for pharmacokinetic studies is required. Plasma samples were ultrasonicated for protein precipitation. A solid-phase extraction was performed. The eluted samples were evaporated to dryness under vacuum, and the solid obtained was diluted and injected into the high-performance liquid chromatography (HPLC) system. Separation of lenalidomide was performed on an Xterra RP C18 (250 mm length × 4.6 mm i.d., 5 µm) using a mobile phase consisting of phosphate buffer/acetonitrile (85:15, v/v, pH 3.2) at a flow rate of 0.5 mL · min -1 The samples were monitored at a wavelength of 311 nm. A linear relationship with good correlation coefficient (r = 0.997, n = 9) was found between the peak area and lenalidomide concentrations in the range of 100 to 950 ng · mL -1 The limits of detection and quantitation were 28 and 100 ng · mL -1 , respectively. The intra- and interassay precisions were satisfactory, and the accuracy of the method was proved. In conclusion, the proposed method is suitable for the accurate quantification of lenalidomide in human plasma with a wide linear range, from 100 to 950 ng · mL -1 This is a valuable method for pharmacokinetic studies of lenalidomide in human subjects. © 2016 Society for Laboratory Automation and Screening.

  11. CPU time optimization and precise adjustment of the Geant4 physics parameters for a VARIAN 2100 C/D gamma radiotherapy linear accelerator simulation using GAMOS.

    PubMed

    Arce, Pedro; Lagares, Juan Ignacio

    2018-01-25

    We have verified the GAMOS/Geant4 simulation model of a 6 MV VARIAN Clinac 2100 C/D linear accelerator by the procedure of adjusting the initial beam parameters to fit the percentage depth dose and cross-profile dose experimental data at different depths in a water phantom. Thanks to the use of a wide range of field sizes, from 2  ×  2 cm 2 to 40  ×  40 cm 2 , a small phantom voxel size and high statistics, fine precision in the determination of the beam parameters has been achieved. This precision has allowed us to make a thorough study of the different physics models and parameters that Geant4 offers. The three Geant4 electromagnetic physics sets of models, i.e. Standard, Livermore and Penelope, have been compared to the experiment, testing the four different models of angular bremsstrahlung distributions as well as the three available multiple-scattering models, and optimizing the most relevant Geant4 electromagnetic physics parameters. Before the fitting, a comprehensive CPU time optimization has been done, using several of the Geant4 efficiency improvement techniques plus a few more developed in GAMOS.

  12. Development and Validation of RP-HPLC Method for the Estimation of Ivabradine Hydrochloride in Tablets

    PubMed Central

    Seerapu, Sunitha; Srinivasan, B. P.

    2010-01-01

    A simple, sensitive, precise and robust reverse–phase high-performance liquid chromatographic method for analysis of ivabradine hydrochloride in pharmaceutical formulations was developed and validated as per ICH guidelines. The separation was performed on SS Wakosil C18AR, 250×4.6 mm, 5 μm column with methanol:25 mM phosphate buffer (60:40 v/v), adjusted to pH 6.5 with orthophosphoric acid, added drop wise, as mobile phase. A well defined chromatographic peak of Ivabradine hydrochloride was exhibited with a retention time of 6.55±0.05 min and tailing factor of 1.14 at the flow rate of 0.8 ml/min and at ambient temperature, when monitored at 285 nm. The linear regression analysis data for calibration plots showed good linear relationship with R=0.9998 in the concentration range of 30-210 μg/ml. The method was validated for precision, recovery and robustness. Intra and Inter-day precision (% relative standard deviation) were always less than 2%. The method showed the mean % recovery of 99.00 and 98.55 % for Ivabrad and Inapure tablets, respectively. The proposed method has been successfully applied to the commercial tablets without any interference of excipients. PMID:21695008

  13. New Stability-Indicating RP-HPLC Method for Determination of Diclofenac Potassium and Metaxalone from their Combined Dosage Form

    PubMed Central

    Panda, Sagar Suman; Patanaik, Debasis; Ravi Kumar, Bera V. V.

    2012-01-01

    A simple, precise and accurate isocratic RP-HPLC stability-indicating assay method has been developed to determine diclofenac potassium and metaxalone in their combined dosage forms. Isocratic separation was achieved on a Hibar-C18, Lichrosphere-100® (250 mm × 4.6 mm i.d., particle size 5 μm) column at room temperature in isocratic mode, the mobile phase consists of methanol: water (80:20, v/v) at a flow rate of 1.0 ml/min, the injection volume was 20 μl and UV detection was carried out at 280nm. The drug was subjected to acid and alkali hydrolysis, oxidation, photolysis and heat as stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness and system suitability. The method was linear in the drug concentration range of 2.5–30 μg/ml and 20–240 μg/ml for diclofenac potassium and metaxalone, respectively. The precision (RSD) of six samples was 0.83 and 0.93% for repeatability, and the intermediate precision (RSD) among six-sample preparation was 1.63 and 0.49% for diclofenac potassium and metaxalone, respectively. The mean recoveries were between 100.99–102.58% and 99.97–100.01% for diclofenac potassium and metaxalone, respectively. The proposed method can be used successfully for routine analysis of the drug in bulk and combined pharmaceutical dosage forms. PMID:22396909

  14. Simultaneous Determination of Soyasaponins and Isoflavones in Soy (Glycine max L.) Products by HPTLC-densitometry-Multiple Detection.

    PubMed

    Shawky, Eman; Sallam, Shaimaa M

    2017-11-01

    A new high-throughput method was developed for the simultaneous analysis of isoflavones and soyasaponnins in Soy (Glycine max L.) products by high-performance thin-layer chromatography with densitometry and multiple detection. Silica gel was used as the stationary phase and ethyl acetate:methanol:water:acetic acid (100:20:16:1, v/v/v/v) as the mobile phase. After chromatographic development, multi-wavelength scanning was carried out by: (i) UV-absorbance measurement at 265 nm for genistin, daidzin and glycitin, (ii) Vis-absorbance measurement at 650 nm for Soyasaponins I and III, after post-chromatographic derivatization with anisaldehyde/sulfuric acid reagent. Validation of the developed method was found to meet the acceptance criteria delineated by ICH guidelines with respect to linearity, accuracy, precision, specificity and robustness. Calibrations were linear with correlation coefficients of >0.994. Intra-day precisions relative standard deviation (RSD)% of all substances in matrix were determined to be between 0.7 and 0.9%, while inter-day precisions (RSD%) ranged between 1.2 and 1.8%. The validated method was successfully applied for determination of the studied analytes in soy-based infant formula and soybean products. The new method compares favorably to other reported methods in being as accurate and precise and in the same time more feasible and cost-effective. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Simultaneous Determination of Potassium Clavulanate and Amoxicillin Trihydrate in Bulk, Pharmaceutical Formulations and in Human Urine Samples by UV Spectrophotometry

    PubMed Central

    Gujral, Rajinder Singh; Haque, Sk Manirul

    2010-01-01

    A simple and sensitive UV spectrophotometric method was developed and validated for the simultaneous determination of Potassium Clavulanate (PC) and Amoxicillin Trihydrate (AT) in bulk, pharmaceutical formulations and in human urine samples. The method was linear in the range of 0.2–8.5 μg/ml for PC and 6.4–33.6 μg/ml for AT. The absorbance was measured at 205 and 271 nm for PC and AT respectively. The method was validated with respect to accuracy, precision, specificity, ruggedness, robustness, limit of detection and limit of quantitation. This method was used successfully for the quality assessment of four PC and AT drug products and in human urine samples with good precision and accuracy. This is found to be simple, specific, precise, accurate, reproducible and low cost UV Spectrophotometric method. PMID:23675211

  16. In vivo precision of the GE Lunar iDXA densitometer for the measurement of total-body, lumbar spine, and femoral bone mineral density in adults.

    PubMed

    Hind, Karen; Oldroyd, Brian; Truscott, John G

    2010-01-01

    Knowledge of precision is integral to the monitoring of bone mineral density (BMD) changes using dual-energy X-ray absorptiometry (DXA). We evaluated the precision for bone measurements acquired using a GE Lunar iDXA (GE Healthcare, Waukesha, WI) in self-selected men and women, with mean age of 34.8 yr (standard deviation [SD]: 8.4; range: 20.1-50.5), heterogeneous in terms of body mass index (mean: 25.8 kg/m(2); SD: 5.1; range: 16.7-42.7 kg/m(2)). Two consecutive iDXA scans (with repositioning) of the total body, lumbar spine, and femur were conducted within 1h, for each subject. The coefficient of variation (CV), the root-mean-square (RMS) averages of SDs of repeated measurements, and the corresponding 95% least significant change were calculated. Linear regression analyses were also undertaken. We found a high level of precision for BMD measurements, particularly for scans of the total body, lumbar spine, and total hip (RMS: 0.007, 0.004, and 0.007 g/cm(2); CV: 0.63%, 0.41%, and 0.53%, respectively). Precision error for the femoral neck was higher but still represented good reproducibility (RMS: 0.014 g/cm(2); CV: 1.36%). There were associations between body size and total-body BMD and total-hip BMD SD precisions (r=0.534-0.806, p<0.05) in male subjects. Regression parameters showed good association between consecutive measurements for all body sites (r(2)=0.98-0.99). The Lunar iDXA provided excellent precision for BMD measurements of the total body, lumbar spine, femoral neck, and total hip. Copyright © 2010 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  17. Measurement precision in a series of visual fields acquired by the standard and fast versions of the Swedish interactive thresholding algorithm: analysis of large-scale data from clinics.

    PubMed

    Saunders, Luke J; Russell, Richard A; Crabb, David P

    2015-01-01

    Swedish Interactive Thresholding Algorithm (SITA) testing strategies for the Humphrey Field Analyzer have become a clinical standard. Measurements from SITA Fast are thought to be more variable than SITA Standard, yet some clinics routinely use SITA Fast because it is quicker. To examine the measurement precision of the 2 SITA strategies across a range of sensitivities using a large number of visual field (VF) series from 4 glaucoma clinics in England. Retrospective cohort study at Moorfields Eye Hospital in London, England; Gloucestershire Eye Unit at Cheltenham General Hospital; Queen Alexandra Hospital in Portsmouth, England; and the Calderdale and Huddersfield National Health Service Foundation Trust that included 66,974 Humphrey 24-2 SITA Standard VFs (10,124 eyes) and 19,819 Humphrey 24-2 SITA Fast VFs (3654 eyes) recorded between May 20, 1997, and September 20, 2012. Pointwise ordinary least squares linear regression of measured sensitivity over time was conducted using VF series of 1 random eye from each patient. Residuals from the regression were pooled according to fitted sensitivities. For each sensitivity (decibel) level, the standard deviation of the residuals was used to estimate measurement precision and were compared for SITA Standard and SITA Fast. Simulations of progression from different VF baselines were used to evaluate how different levels of precision would affect time to detect VF progression. Median years required to detect progression. Median (interquartile range) patient age, follow-up, and series lengths for SITA Standard were 64 (53-72) years, 6.0 (4.0-8.5) years, and 6 (4-8) VFs, respectively; for SITA Fast, medians (interquartile range) were 70 (61-78) years, 5.1 (3.2-7.3) years, and 5 (4-6) VFs. Measurement precision worsened as sensitivity decreased for both test strategies. In the 20 to 5 dB range, SITA Fast was less precise than SITA Standard; this difference was largest between 15 to 10 dB, where variability in both methods peaked. Translated to median time to detection, differences in measurement precision were negligible, suggesting minimal effects on time to detect progression. Although SITA Standard is a more precise testing algorithm than SITA Fast at lower VF sensitivities, it is unlikely to make a sizeable difference to improving the time to detect VF progression.

  18. Application of snapshot imaging spectrometer in environmental detection

    NASA Astrophysics Data System (ADS)

    Sun, Kai; Qin, Xiaolei; Zhang, Yu; Wang, Jinqiang

    2017-10-01

    This study aimed at the application of snapshot imaging spectrometer in environmental detection. The simulated sewage and dyeing wastewater were prepared and the optimal experimental conditions were determined. The white LED array was used as the detection light source and the image of the sample was collected by the imaging spectrometer developed in the laboratory to obtain the spectral information of the sample in the range of 400-800 nm. The standard curve between the absorbance and the concentration of the samples was established. The linear range of a single component of Rhoda mine B was 1-50 mg/L, the linear correlation coefficient was more than 0.99, the recovery was 93%-113% and the relative standard deviations (RSD) was 7.5%. The linear range of chemical oxygen demand (COD) standard solution was 50-900mg/L, the linear correlation coefficient was 0.981, the recovery was 91% -106% and the relative standard deviation (RSD) was 6.7%. The rapid, accurate and precise method for detecting dyes showed an excellent promise for on-site and emergency detection in environment. At the request of the proceedings editor, an updated version of this article was published on 17 October 2017. The original version of this article was replaced due to an accidental inversion of Figure 2 and Figure 3. The Figures have been corrected in the updated and republished version.

  19. Generalised optical differentiation wavefront sensor: a sensitive high dynamic range wavefront sensor.

    PubMed

    Haffert, S Y

    2016-08-22

    Current wavefront sensors for high resolution imaging have either a large dynamic range or a high sensitivity. A new kind of wavefront sensor is developed which can have both: the Generalised Optical Differentiation wavefront sensor. This new wavefront sensor is based on the principles of optical differentiation by amplitude filters. We have extended the theory behind linear optical differentiation and generalised it to nonlinear filters. We used numerical simulations and laboratory experiments to investigate the properties of the generalised wavefront sensor. With this we created a new filter that can decouple the dynamic range from the sensitivity. These properties make it suitable for adaptive optic systems where a large range of phase aberrations have to be measured with high precision.

  20. Comparison of two-concentration with multi-concentration linear regressions: Retrospective data analysis of multiple regulated LC-MS bioanalytical projects.

    PubMed

    Musuku, Adrien; Tan, Aimin; Awaiye, Kayode; Trabelsi, Fethi

    2013-09-01

    Linear calibration is usually performed using eight to ten calibration concentration levels in regulated LC-MS bioanalysis because a minimum of six are specified in regulatory guidelines. However, we have previously reported that two-concentration linear calibration is as reliable as or even better than using multiple concentrations. The purpose of this research is to compare two-concentration with multiple-concentration linear calibration through retrospective data analysis of multiple bioanalytical projects that were conducted in an independent regulated bioanalytical laboratory. A total of 12 bioanalytical projects were randomly selected: two validations and two studies for each of the three most commonly used types of sample extraction methods (protein precipitation, liquid-liquid extraction, solid-phase extraction). When the existing data were retrospectively linearly regressed using only the lowest and the highest concentration levels, no extra batch failure/QC rejection was observed and the differences in accuracy and precision between the original multi-concentration regression and the new two-concentration linear regression are negligible. Specifically, the differences in overall mean apparent bias (square root of mean individual bias squares) are within the ranges of -0.3% to 0.7% and 0.1-0.7% for the validations and studies, respectively. The differences in mean QC concentrations are within the ranges of -0.6% to 1.8% and -0.8% to 2.5% for the validations and studies, respectively. The differences in %CV are within the ranges of -0.7% to 0.9% and -0.3% to 0.6% for the validations and studies, respectively. The average differences in study sample concentrations are within the range of -0.8% to 2.3%. With two-concentration linear regression, an average of 13% of time and cost could have been saved for each batch together with 53% of saving in the lead-in for each project (the preparation of working standard solutions, spiking, and aliquoting). Furthermore, examples are given as how to evaluate the linearity over the entire concentration range when only two concentration levels are used for linear regression. To conclude, two-concentration linear regression is accurate and robust enough for routine use in regulated LC-MS bioanalysis and it significantly saves time and cost as well. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation by ultra-high performance liquid chromatography coupled with nano quantity analyte detector.

    PubMed

    Zhang, Honggen; Wang, Zhenyu; Liu, Oscar

    2016-02-01

    A novel method for simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation was developed using ultra-high performance liquid chromatography coupled with a nano quantitation analytical detector (UHPLC-NQAD). All components in kolliphor HS15 and miglyol 812 were well separated on an Acquity BEH C 18 column. Mobile phase A was 0.1% trifluoroacetic acid (TFA) in water and mobile phase B was acetonitrile. A gradient elution sequence was programed initially with 60% organic solvent, slowly increased to 100% within 8 min. The flow rate was 0.7 mL/min. Good linearity ( r >0.95) was obtained in the range of 27.6-1381.1 μg/mL for polyoxyl 15 hydroxystearate in kolliphor HS15, 0.8-202.0 μg/mL for caprylic acid triglyceride and 2.7-221.9 μg/mL for capric acid triglyceride in miglyol 812. The relative standard deviations (RSD) ranged from 0.6% to 1.7% for intra-day precision and from 0.4% to 2.7% for inter-day precision. The overall recoveries (accuracy) were 99.7%-101.4% for polyoxyl 15 hydroxystearate in kolliphor HS15, 96.7%-99.6% for caprylic acid triglyceride, and 94.1%-103.3% for capric acid triglyceride in miglyol 812. Quantification limits (QL) were determined as 27.6 μg/mL for polyoxyl 15 hydroxystearate in kolliphor HS15, 0.8 μg/mL for caprylic acid triglyceride, and 2.7 μg/mL for capric acid triglyceride in miglyol 812. No interferences were observed in the retention time ranges of kolliphor HS15 and miglyol 812. The method was validated in terms of specificity, linearity, precision, accuracy, QL, and robustness. The proposed method has been applied to microemulsion formulation analyses with good recoveries (82.2%-103.4%).

  2. Validation of a rapid micellar electrokinetic capillary chromatographic method for the simultaneous determination of isoniazid and pyridoxine hydrochloride in pharmaceutical formulation.

    PubMed

    Nemutlu, E; Celebier, M; Uyar, B; Altinöz, S

    2007-07-01

    An efficient and reliable micellar electrokinetic capillary chromatography (MEKC) method has been developed for the simultaneous determination of isoniazid (ISO) and pyridoxine hydrochloride (PYR) in pharmaceutical formulations. A chemometric two level full factorial design approach was used to search for the optimum conditions of separation. Three parameters were selected for this study: the buffer pH, the buffer concentration and sodium dodecyl sulphate (SDS) concentrations. Resolution, peak symmetry and analysis time were established as response. The two analytes were separated within 6 min with the optimized conditions: 50 mM borate buffer, 25 mM SDS pH 7.8, 35 degrees C, at 50 mbar 4s injection and 30 kV by using a fused silica capillary (72 cm effective length, 50 microm i.d.). The detection wavelength was set to 205 nm. Meloxicam was used as internal standard. The method was validated with respect to stability, linearity range, limit of quantitation and detection, precision, accuracy, specificity and robustness. The detection limits of the method were 1.0 microg mL(-1) for ISO and 0.40 microg mL(-1) for PYR and the method was linear at least in the range of 3.0-100 microg mL(-1) for ISO and 1.0-100 microg mL(-1) for PYR with excellent correlation coefficients (0.9995 for ISO and 0.9998 for PYR). Relative standard deviations (R.S.D.s) of the described method ranged between 0.54 and 2.27% for intra-day precision and between 0.65 and 2.69% for inter-day precision. The developed method was applied to the tablet form of ISO and PYR-containing the pharmaceutical preparations and the data were compared with obtained from the standard addition method. No statistically significant difference was found.

  3. Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants.

    PubMed

    Giraldo-Cadavid, Luis F; Agudelo-Otalora, Luis Mauricio; Burguete, Javier; Arbulu, Mario; Moscoso, William Daniel; Martínez, Fabio; Ortiz, Andrés Felipe; Diaz, Juan; Pantoja, Jaime A; Rueda-Arango, Andrés Felipe; Fernández, Secundino

    2016-05-10

    Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device for exploring LPMS is limited because it assesses only the laryngeal adductor reflex during fiber-optic endoscopic evaluations of swallowing and requires a high degree of expertise to obtain reliable results, introducing intrinsic expert variability and subjectivity. We designed, developed and validated a new air-pulse laryngo-pharyngeal endoscopic esthesiometer with a built-in laser range-finder (LPEER) based on the evaluation and control of air-pulse variability determinants and on intrinsic observer variability and subjectivity determinants of the distance, angle and site of stimulus impact. The LPEER was designed to be capable of delivering precise and accurate stimuli with a wide range of intensities that can explore most laryngo-pharyngeal reflexes. We initially explored the potential factors affecting the reliability of LPMS tests and included these factors in a multiple linear regression model. The following factors significantly affected the precision and accuracy of the test (P < 0.001): the tube conducting the air-pulses, the supply pressure of the system, the duration of the air-pulses, and the distance and angle between the end of the tube conducting the air-pulses and the site of impact. To control all of these factors, an LPEER consisting of an air-pulse generator and an endoscopic laser range-finder was designed and manufactured. We assessed the precision and accuracy of the LPEER's stimulus and range-finder according to the coefficient of variation (CV) and by looking at the differences between the measured properties and the desired values, and we performed a pilot validation on ten human subjects. The air-pulses and range-finder exhibited good precision and accuracy (CV < 0.06), with differences between the desired and measured properties at <3 % and a range-finder measurement error of <1 mm. The tests in patients demonstrated obtainable and reproducible thresholds for the laryngeal adductor, cough and gag reflexes. The new LPEER was capable of delivering precise and accurate stimuli for exploring laryngo-pharyngeal reflexes.

  4. Clinical laboratory investigation of the Sanofi ACCESS CK-MB procedure and comparison to electrophoresis and Abbott IMx.

    PubMed

    Mao, G D; Adeli, K; Eisenbrey, A B; Artiss, J D

    1996-07-01

    This evaluation was undertaken to verify the application protocol for the CK-MB assay on the ACCESS Immunoassay Analyzer (Sanofi Diagnostics Pasteur, Chaska, MN). The results show that the ACCESS CK-MB assay total imprecision was 6.8% to 9.1%. Analytical linearity of the ACCESS CK-MB assay was excellent in the range of < 1-214 micrograms/L. A comparison of the ACCESS CK-MB assay with the IMx (Abbott Laboratories, Abbott Park, IL) method shows good correlation r = 0.990 (n = 108). Linear regression analysis yielded Y = 1.36X-0.3, Sx/y = 7.2. ACCESS CK-MB values also correlated well with CK-MB by electrophoresis with r = 0.968 (n = 132). The linear regression equation for this comparison was Y = 1.08X + 1.4, Sx/y = 14.1. The expected non-myocardial infarction range of CK-MB determined by the ACCESS system was 1.3-9.4 micrograms/L (mean = 4.0, n = 58). The ACCESS CK-MB assay would appear to be rapid, precise and clinically useful.

  5. Simultaneous quantification of coumarins, flavonoids and limonoids in Fructus Citri Sarcodactylis by high performance liquid chromatography coupled with diode array detector.

    PubMed

    Chu, Jun; Li, Song-Lin; Yin, Zhi-Qi; Ye, Wen-Cai; Zhang, Qing-Wen

    2012-07-01

    A high performance liquid chromatography coupled with diode array detector (HPLC-DAD) method was developed for simultaneous quantification of eleven major bioactive components including six coumarins, three flavonoids and two limonoids in Fructus Citri Sarcodactylis. The analysis was performed on a Cosmosil 5 C(18)-MS-II column (4.6 mm × 250 mm, 5 μm) with water-acetonitrile gradient elution. The method was validated in terms of linearity, sensitivity, precision, stability and accuracy. It was found that the calibration curves for all analytes showed good linearity (R(2)>0.9993) within the test ranges. The overall limit of detection (LOD) and limit of quantification (LOQ) were less than 3.0 and 10.2 ng. The relative standard deviations (RSDs) for intra- and inter-day repeatability were not more than 4.99% and 4.92%, respectively. The sample was stable for at least 48 h. The spike recoveries of eleven components were 95.1-104.9%. The established method was successfully applied to determine eleven components in three samples from different locations. The results showed that the newly developed HPLC-DAD method was linear, sensitive, precise and accurate, and could be used for quality control of Fructus Citri Sarcodactylis. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Validation of a LC/MS method for the determination of gemfibrozil in human plasma and its application to a pharmacokinetic study

    PubMed Central

    Rower, Joseph E.; Bushman, Lane R.; Hammond, Kyle P.; Kadam, Rajendra S.; Aquilante, Christina L.

    2011-01-01

    Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate, and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6% and 10.7%, and inter-assay precision ranging from 4.4% to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6% and 108.7% of the expected value, and inter-assay concentrations within 89.4 to 104.0% of the expected value. The linear concentration range was between 0.5 and 50 μg/mL with a lower limit of quantitation of 0.5 μg/mL when 125 μL of plasma were extracted. This LC/MS method yielded a quick, simple, and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. PMID:21077249

  7. Validation of an LC/MS method for the determination of gemfibrozil in human plasma and its application to a pharmacokinetic study.

    PubMed

    Rower, Joseph E; Bushman, Lane R; Hammond, Kyle P; Kadam, Rajendra S; Aquilante, Christina L

    2010-12-01

    Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6 and 10.7%, and inter-assay precision ranging from 4.4 to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6-108.7% of the expected value, and inter-assay concentrations within 89.4-104.0% of the expected value. The linear concentration range was between 0.5 and 50 µg/mL with a lower limit of quantitation of 0.5 µg/mL when 125 µL of plasma were extracted. This LC/MS method yielded a quick, simple and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd.

  8. Simple and sensitive method for the quantification of total bilirubin in human serum using 3-methyl-2-benzothiazolinone hydrazone hydrochloride as a chromogenic probe

    NASA Astrophysics Data System (ADS)

    Nagaraja, Padmarajaiah; Avinash, Krishnegowda; Shivakumar, Anantharaman; Dinesh, Rangappa; Shrestha, Ashwinee Kumar

    2010-11-01

    We here describe a new spectrophotometric method for measuring total bilirubin in serum. The method is based on the cleavage of bilirubin giving formaldehyde which further reacts with diazotized 3-methyl-2-benzothiazolinone hydrazone hydrochloride giving blue colored solution with maximum absorbance at 630 nm. Sensitivity of the developed method was compared with Jendrassik-Grof assay procedure and its applicability has been tested with human serum samples. Good correlation was attained between both methods giving slope of 0.994, intercept 0.015, and R2 = 0.997. Beers law obeyed in the range of 0.068-17.2 μM with good linearity, absorbance y = 0.044 Cbil + 0.003. Relative standard deviation was 0.006872, within day precision ranged 0.3-1.2% and day-to-day precision ranged 1-6%. Recovery of the method varied from 97 to 102%. The proposed method has higher sensitivity with less interference. The obtained product was extracted and was spectrally characterized for structural confirmation with FT-IR, 1H NMR.

  9. Constraining new physics models with isotope shift spectroscopy

    NASA Astrophysics Data System (ADS)

    Frugiuele, Claudia; Fuchs, Elina; Perez, Gilad; Schlaffer, Matthias

    2017-07-01

    Isotope shifts of transition frequencies in atoms constrain generic long- and intermediate-range interactions. We focus on new physics scenarios that can be most strongly constrained by King linearity violation such as models with B -L vector bosons, the Higgs portal, and chameleon models. With the anticipated precision, King linearity violation has the potential to set the strongest laboratory bounds on these models in some regions of parameter space. Furthermore, we show that this method can probe the couplings relevant for the protophobic interpretation of the recently reported Be anomaly. We extend the formalism to include an arbitrary number of transitions and isotope pairs and fit the new physics coupling to the currently available isotope shift measurements.

  10. Analysis of 10 metabolites of polymethoxyflavones with high sensitivity by electrochemical detection in high-performance liquid chromatography.

    PubMed

    Zheng, Jinkai; Bi, Jinfeng; Johnson, David; Sun, Yue; Song, Mingyue; Qiu, Peiju; Dong, Ping; Decker, Eric; Xiao, Hang

    2015-01-21

    Polymethoxyflavones (PMFs) have been known as a type of bioactive flavones that possess various beneficial biological functions. Accumulating evidence demonstrated that the metabolites of PMFs, that is, hydroxyl PMFs (OH-PMFs), had more potent beneficial biological effects than their corresponding parent PMFs. To facilitate the further identification and quantification of OH-PMFs in biological samples, the aim of this study was to develop a methodology for the simultaneous determination of 10 OH-PMFs using high-performance liquid chromatography (HPLC) coupled with electrochemistry detection. The HPLC profiles of these 10 OH-PMFs affected by different chromatographic parameters (different organic composition in mobile phases, the concentration of trifluoroacetic acid, and the concentration of ammonium acetate) are fully discussed in this study. The optimal condition was selected for the following validation studies. The linearity of calibration curves, accuracy, and precision (intra- and interday) at three concentration levels (low, middle, and high concentration range) were verified. The regression equations were linear (r > 0.9992) over the range of 0.005-10 μM. The limit of detection for 10 OH-PMFs was in the range of 0.8-3.7 ng/mL (S/N = 3, 10 μL injection). The recovery rates ranged from 86.6 to 108.7%. The precisions of intraday and interday analyses were less than 7.37 and 8.63% for relative standard deviation, respectively. This validated method was applied for the analysis of a variety of samples containing OH-PMFs. This paper also gives an example of analyzing the metabolites of nobiletin in mouse urine using the developed method. The transformation from nobiletin to traces of 5-hydroxyl metabolites has been discovered by this effective method, and this is the first paper to report such an association.

  11. UV Spectrophotometric Determination and Validation of Hydroquinone in Liposome.

    PubMed

    Khoshneviszadeh, Rabea; Fazly Bazzaz, Bibi Sedigheh; Housaindokht, Mohammad Reza; Ebrahim-Habibi, Azadeh; Rajabi, Omid

    2015-01-01

    The method has been developed and validated for the determination of hydroquinone in liposomal formulation. The samples were dissolved in methanol and evaluated in 293 nm. The validation parameters such as linearity, accuracy, precision, specificity, limit of detection (LOD) and limit of quantitation (LOQ) were determined. The calibration curve was linear in 1-50 µg/mL range of hydroquinone analyte with a regression coefficient of 0.9998. This study showed that the liposomal hydroquinone composed of phospholipid (7.8 %), cholesterol (1.5 %), alpha ketopherol (0.17 %) and hydroquinone (0.5 %) did not absorb wavelength of 293 nm if it diluted 500 times by methanol. The concentration of hydroquinone reached 10 µg/mL after 500 times of dilution. Furthermore, various validation parameters as per ICH Q2B guideline were tested and found accordingly. The recovery percentages of liposomal hydroquinone were found 102 ± 0.8, 99 ± 0.2 and 98 ± 0.4 for 80%, 100% and 120% respectively. The relative standard deviation values of inter and intra-day precisions were <%2. LOD and LOQ were 0.24 and 0.72 µg/mL respectively.

  12. RP-HPLC Method Development and Validation for Determination of Eptifibatide Acetate in Bulk Drug Substance and Pharmaceutical Dosage Forms.

    PubMed

    Bavand Savadkouhi, Maryam; Vahidi, Hossein; Ayatollahi, Abdul Majid; Hooshfar, Shirin; Kobarfard, Farzad

    2017-01-01

    A new, rapid, economical and isocratic reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of eptifibatide acetate, a small synthetic antiplatelet peptide, in bulk drug substance and pharmaceutical dosage forms. The developed method was validated as per of ICH guidelines. The chromatographic separation was achieved isocratically on C18 column (150 x 4.60 mm i.d., 5 µM particle size) at ambient temperature using acetonitrile (ACN), water and trifluoroacetic acid (TFA) as mobile phase at flow rate of 1 mL/min and UV detection at 275 nm. Eptifibatide acetate exhibited linearity over the concentration range of 0.15-2 mg/mL (r 2 =0.997) with limit of detection of 0.15 mg/mL The accuracy of the method was 96.4-103.8%. The intra-day and inter-day precision were between 0.052% and 0.598%, respectively. The present successfully validated method with excellent selectivity, linearity, sensitivity, precision and accuracy was applicable for the assay of eptifibatide acetate in bulk drug substance and pharmaceutical dosage forms.

  13. Electron kinetic effects on interferometry, polarimetry and Thomson scattering measurements in burning plasmas (invited).

    PubMed

    Mirnov, V V; Brower, D L; Den Hartog, D J; Ding, W X; Duff, J; Parke, E

    2014-11-01

    At anticipated high electron temperatures in ITER, the effects of electron thermal motion on Thomson scattering (TS), toroidal interferometer/polarimeter (TIP), and poloidal polarimeter (PoPola) diagnostics will be significant and must be accurately treated. The precision of the previous lowest order linear in τ = Te/mec(2) model may be insufficient; we present a more precise model with τ(2)-order corrections to satisfy the high accuracy required for ITER TIP and PoPola diagnostics. The linear model is extended from Maxwellian to a more general class of anisotropic electron distributions that allows us to take into account distortions caused by equilibrium current, ECRH, and RF current drive effects. The classical problem of the degree of polarization of incoherent Thomson scattered radiation is solved analytically exactly without any approximations for the full range of incident polarizations, scattering angles, and electron thermal motion from non-relativistic to ultra-relativistic. The results are discussed in the context of the possible use of the polarization properties of Thomson scattered light as a method of Te measurement relevant to ITER operational scenarios.

  14. Determination of lipophilic marine toxins in mussels. Quantification and confirmation criteria using high resolution mass spectrometry.

    PubMed

    Domènech, Albert; Cortés-Francisco, Nuria; Palacios, Oscar; Franco, José M; Riobó, Pilar; Llerena, José J; Vichi, Stefania; Caixach, Josep

    2014-02-07

    A multitoxin method has been developed for quantification and confirmation of lipophilic marine biotoxins in mussels by liquid chromatography coupled to high resolution mass spectrometry (HRMS), using an Orbitrap-Exactive HCD mass spectrometer. Okadaic acid (OA), yessotoxin, azaspiracid-1, gymnodimine, 13-desmethyl spirolide C, pectenotoxin-2 and Brevetoxin B were analyzed as representative compounds of each lipophilic toxin group. HRMS identification and confirmation criteria were established. Fragment and isotope ions and ion ratios were studied and evaluated for confirmation purpose. In depth characterization of full scan and fragmentation spectrum of the main toxins were carried out. Accuracy (trueness and precision), linearity, calibration curve check, limit of quantification (LOQ) and specificity were the parameters established for the method validation. The validation was performed at 0.5 times the current European Union permitted levels. The method performed very well for the parameters investigated. The trueness, expressed as recovery, ranged from 80% to 94%, the precision, expressed as intralaboratory reproducibility, ranged from 5% to 22% and the LOQs range from 0.9 to 4.8pg on column. Uncertainty of the method was also estimated for OA, using a certified reference material. A top-down approach considering two main contributions: those arising from the trueness studies and those coming from the precision's determination, was used. An overall expanded uncertainty of 38% was obtained. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Application of a fast and cost-effective in situ derivatization method prior to gas chromatography with mass spectrometry to monitor endocrine disruptors in water matrices.

    PubMed

    Melo, Armindo; Ferreira, Isabel M P L V O; Mansilha, Catarina

    2015-06-01

    This work deals with the optimization of a rapid, cost-effective, and eco-friendly gas chromatography with mass spectrometry method for the simultaneous determination of four endocrine disruptor compounds in water matrices: estrone, 17β-estradiol, 17α-ethinylestradiol, and bisphenol A, that are currently considered to be of main concern in the field of water policy and that could became candidates for future regulations. The method involves simultaneous derivatization and extraction of compounds by dispersive liquid-liquid microextraction followed by gas chromatography with mass spectrometry analysis. Derivatization and extraction parameters were optimized with the aid of experimental design approach. An excellent linear response was achieved for all analytes (r(2) ≥ 0.999). Limits of detection and quantification are 0.003-0.005 and 0.0094-0.0164 μg/L, respectively. Intraday precision ranged between 1.1 and 12.6%, whereas interday precision ranged between 0.5 and 14.7%. For accuracy, bias values varied between -15.0 and 13.7%. Recoveries at three concentration levels ranged from 86.4 to 118.2%. The proposed method can be applied to the routine analysis of groundwater, river, sea, tap, and mineral water samples with excellent sensitivity, precision, and accuracy. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector.

    PubMed

    Lee, Jiwoo; Weon, Jin Bae; Yun, Bo-Ra; Eom, Min Rye; Ma, Choong Je

    2015-01-01

    Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography-mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established. The analytes were separated on a Shiseido C18 column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm. Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R (2) > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55-7.07 μg/mL and 1.67-21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03-104.91%. The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea.

  17. Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector

    PubMed Central

    Lee, Jiwoo; Weon, Jin Bae; Yun, Bo-Ra; Eom, Min Rye; Ma, Choong Je

    2015-01-01

    Background: Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. Objective: An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography–mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established. Materials and Methods: The analytes were separated on a Shiseido C18 column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm. Results: Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R2 > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55–7.07 μg/mL and 1.67–21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03–104.91%. Conclusion: The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea. PMID:25829768

  18. A HPLC-DAD method for the simultaneous determination of five marker components in the traditional herbal medicine Bangpungtongsung-san

    PubMed Central

    Weon, Jin Bae; Yang, Hye Jin; Ma, Jin Yeul; Ma, Choong Je

    2011-01-01

    Background: Bangpungtongsung-san, one of the traditional herbal medicines, was known to be a prescription for obesity. Objective: For the simultaneous determination of five components (paeoniflorin, 6-gingerol, decursin, geniposide, and glycyrrhizin) in Bangpungtongsung-san, a high-performance liquid chromatography with diode-array detector method was established. Materials and Methods: To develop the method, a reverse phase column, DIONEX C 18 (5 μm, 120 µ, 4.6 mm × 150 mm) was used. The mobile phase consisted of methanol and water using a gradient elution. The UV wavelength was set at 230, 240, and 254 nm. Method validation was accomplished by linearity, precision test, and recovery test. Results: All calibration curves of components showed good linearity (R 2 > 0.9959). The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.01 to 0.17 μg/ml and 0.04 to 0.53 μg/ml, respectively. The relative standard deviations (RSD) value of precision test, intraday and interday tests were less than 0.43% and 1.26%. In the recovery test, results of accuracy ranged from 95.27% to 107.70% with RSD values less than 2.21%. Conclusion: This developed method was applied to the commercial Bangpungtongsung-san sample and the five marker components were separated effectively without interference of any peaks of components. PMID:21472081

  19. Simultaneous determination of isochamaejasmin, neochamaejasmin A and aphnoretinin rat plasma by UPLC-MS/MS and its application to a pharmacokinetic study of Stellera chamaejasme L. extract.

    PubMed

    Wang, Ludi; Yang, Wei; Wu, Siyang; Wang, Shuyao; Kang, Chen; Ma, Xiaoli; Li, Yingfei; Li, Chuan

    2018-05-01

    Isochamaejasmin, neochamaejasmin A and daphnoretin derived from Stellera chamaejasme L. are important because of their reported anticancer properties. In this study, a sensitive UPLC-MS/MS method for the determination of isochamaejasmin, neochamaejasmin A and daphnoretin in rat plasma was developed. The analyte and IS were separated on an Acquity UPLC HSS T3 column (100 × 2.1 mm, 1.8 μm) using gradient elution with the mobile phase of aqueous solution (methanol-water, 1:99, v/v, containing 1 mm formic acid) and organic solution (methanol-water, 99:1, v/v, containing 1 mm formic acid) at a flow rate of 0.3 mL/min. Multiple reaction monitoring mode with negative electrospray ionization interface was carried out to detect the components. The method was validated in terms of specificity, linearity, accuracy, precision, stability, etc. Excellent linear behavior was observed over the certain concentration ranges with the correlation coefficient values >0.99. Intra- and inter-day precisions (RSD) were <6.7% and accuracy (RE) ranged from -7.0 to 12.0%. The validated method was successfully applied to investigate the pharmacokinetics of three chemical ingredients after oral administration of S. chamaejasme L. extract to rats. Copyright © 2017 John Wiley & Sons, Ltd.

  20. A validated RP-HPLC method for simultaneous determination of propranolol and valsartan in bulk drug and gel formulation

    PubMed Central

    Imam, Syed Sarim; Ahad, Abdul; Aqil, Mohammed; Sultana, Yasmin; Ali, Asgar

    2013-01-01

    Objective: A simple, precise, and stability indicating high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of propranolol hydrochloride and valsartan in pharmaceutical dosage form. Materials and Methods: The method involves the use of easily available inexpensive laboratory reagents. The separation was achieved on Hypersil ODS C-18 column (250*4.6 mm, i.d., 5 μm particle size) with isocratic flow with UV detector. The mobile phase at a flow rate of 1.0 mL/min consisted of acetonitrile, methanol, and 0.01 M disodium hydrogen phosphate (pH 3.5) in the ratio of 50:35:15 v/v. Results: A linear response was observed over the concentration range 5-50 μg/mL of propranolol and the concentration range 4-32 μg/mL of valsartan. Limit of detection and limit of quantitation for propranolol were 0.27 μg/mL and 0.85 μg/mL, and for valsartan were 0.45 μg/mL and 1.39 μg/mL, respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for linearity, accuracy, precision, specificity, robustness. Conclusion: The analysis concluded that the method was selective for simultaneous estimation of propranolol and valsartan can be potentially used for the estimation of these drugs in combined dosage form. PMID:23559826

  1. Development and validation of carbofuran and 3-hydroxycarbofuran analysis by high-pressure liquid chromatography with diode array detector (HPLC-DAD) for forensic Veterinary Medicine.

    PubMed

    Gonçalves, Vagner; Hazarbassanov, Nicolle Queiroz; de Siqueira, Adriana; Florio, Jorge Camilo; Ciscato, Claudia Helena Pastor; Maiorka, Paulo Cesar; Fukushima, André Rinaldi; de Souza Spinosa, Helenice

    2017-10-15

    Agricultural pesticides used with the criminal intent to intoxicate domestic and wild animals are a serious concern in Veterinary Medicine. In order to identify the pesticide carbofuran and its metabolite 3- hydroxycarbofuran in animals suspected of exogenous intoxication a high pressure liquid chromatography with diode array detector (HPLC-DAD) method was developed and validated in stomach contents, liver, vitreous humor and blood. The method was evaluated using biological samples from seven different animal species. The following parameters of analytical validation were evaluated: linearity, precision, accuracy, selectivity, recovery and matrix effect. The method was linear at the range of 6.25-100μg/mL and the correlation coefficient (r 2 ) values were >0.9811 for all matrices. The precision and accuracy of the method was determined by coefficient of variation (CV) and the relative standard deviation error (RSE), and both were less than 15%. Recovery ranged from 74.29 to 100.1% for carbofuran and from 64.72 to 100.61% for 3-hydroxycarbofuran. There were no significant interfering peaks or matrix effects. This method was suitable for detecting 25 positive cases for carbofuran amongst a total of 64 animal samples suspected of poisoning brought to the Toxicology Diagnostic Laboratory, School of Veterinary Medicine and Animal Sciences, University of Sao Paulo. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. 3-D profilometer using a CCD linear image sensor: application to skin surface topography measurement.

    PubMed

    Nita, D; Mignot, J; Chuard, M; Sofa, M

    1998-08-01

    Measurement of cutaneous surface topography can be made by three-dimensional (3-D) profilometry. Different equipment is used for this measurement. The magnitude of the vertical scale required, which can vary from several tens of micrometers (microrelief) to several millimeters (skin pathologies), depends also on the precision required and the duration of acquisition time. Over the last few years, different apparatuses have been produced, with a vertical range that is most frequently used for classical industrial applications, i.e., 0-1000 μm. The system developed here has a wide range of about 7 mm and is accurate enough to analyse each of the different skin surfaces that fall in this range without changing magnification. An optical principle, operating without any contact with a skin replica, allows a precise measurement with a high scanning speed. The profilometer has a vertical sensitivity of 4 μm within a vertical range of 7 mm. This sensitivity is lower than that of a mechanical or focusing profilometer, but the vertical range is wider. The system has several advantages: because of its verticale range, it can measure large surfaces with great roughness variations; the initial position of the replica beneath the profilometer must be within the 7 mm vertical range; and skin topography can be quantified, without contact, in a short time.

  3. Method of orthogonally splitting imaging pose measurement

    NASA Astrophysics Data System (ADS)

    Zhao, Na; Sun, Changku; Wang, Peng; Yang, Qian; Liu, Xintong

    2018-01-01

    In order to meet the aviation's and machinery manufacturing's pose measurement need of high precision, fast speed and wide measurement range, and to resolve the contradiction between measurement range and resolution of vision sensor, this paper proposes an orthogonally splitting imaging pose measurement method. This paper designs and realizes an orthogonally splitting imaging vision sensor and establishes a pose measurement system. The vision sensor consists of one imaging lens, a beam splitter prism, cylindrical lenses and dual linear CCD. Dual linear CCD respectively acquire one dimensional image coordinate data of the target point, and two data can restore the two dimensional image coordinates of the target point. According to the characteristics of imaging system, this paper establishes the nonlinear distortion model to correct distortion. Based on cross ratio invariability, polynomial equation is established and solved by the least square fitting method. After completing distortion correction, this paper establishes the measurement mathematical model of vision sensor, and determines intrinsic parameters to calibrate. An array of feature points for calibration is built by placing a planar target in any different positions for a few times. An terative optimization method is presented to solve the parameters of model. The experimental results show that the field angle is 52 °, the focus distance is 27.40 mm, image resolution is 5185×5117 pixels, displacement measurement error is less than 0.1mm, and rotation angle measurement error is less than 0.15°. The method of orthogonally splitting imaging pose measurement can satisfy the pose measurement requirement of high precision, fast speed and wide measurement range.

  4. In vivo dosimetry with optically stimulated luminescent dosimeters for conformal and intensity-modulated radiation therapy: A 2-year multicenter cohort study.

    PubMed

    Riegel, Adam C; Chen, Yu; Kapur, Ajay; Apicello, Laura; Kuruvilla, Abraham; Rea, Anthony J; Jamshidi, Abolghassem; Potters, Louis

    Optically stimulated luminescent dosimeters (OSLDs) are utilized for in vivo dosimetry (IVD) of modern radiation therapy techniques such as intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). Dosimetric precision achieved with conventional techniques may not be attainable. In this work, we measured accuracy and precision for a large sample of clinical OSLD-based IVD measurements. Weekly IVD measurements were collected from 4 linear accelerators for 2 years and were expressed as percent differences from planned doses. After outlier analysis, 10,224 measurements were grouped in the following way: overall, modality (photons, electrons), treatment technique (3-dimensional [3D] conformal, field-in-field intensity modulation, inverse-planned IMRT, and VMAT), placement location (gantry angle, cardinality, and central axis positioning), and anatomical site (prostate, breast, head and neck, pelvis, lung, rectum and anus, brain, abdomen, esophagus, and bladder). Distributions were modeled via a Gaussian function. Fitting was performed with least squares, and goodness-of-fit was assessed with the coefficient of determination. Model means (μ) and standard deviations (σ) were calculated. Sample means and variances were compared for statistical significance by analysis of variance and the Levene tests (α = 0.05). Overall, μ ± σ was 0.3 ± 10.3%. Precision for electron measurements (6.9%) was significantly better than for photons (10.5%). Precision varied significantly among treatment techniques (P < .0001) with field-in-field lowest (σ = 7.2%) and IMRT and VMAT highest (σ = 11.9% and 13.4%, respectively). Treatment site models with goodness-of-fit greater than 0.90 (6 of 10) yielded accuracy within ±3%, except for head and neck (μ = -3.7%). Precision varied with treatment site (range, 7.3%-13.0%), with breast and head and neck yielding the best and worst precision, respectively. Placement on the central axis of cardinal gantry angles yielded more precise results (σ = 8.5%) compared with other locations (range, 10.5%-11.4%). Accuracy of ±3% was achievable. Precision ranged from 6.9% to 13.4% depending on modality, technique, and treatment site. Simple, standardized locations may improve IVD precision. These findings may aid development of patient-specific tolerances for OSLD-based IVD. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  5. A validated high-performance liquid chromatographic method for the determination of glibenclamide in human plasma and its application to pharmacokinetic studies.

    PubMed

    Niopas, Ioannis; Daftsios, Athanasios C

    2002-05-15

    Glibenclamide is a potent second generation oral sulfonylurea antidiabetic agent widely used for the treatment of type II diabetes melitus. A rapid, sensitive, precise, accurate and specific HPLC assay for the determination of glibenclamide in human plasma was developed and validated. After addition of flufenamic acid as internal standard, the analytes were isolated from human plasma by liquid-liquid extraction. The method was linear in the 10-400 ng/ml concentration range (r > 0.999). Recovery for glibenclamide was greater than 91.5% and for internal standard was 93.5%. Within-day and between-day precision, expressed as the relative standard deviation (RSD%), ranged from 1.4 to 5.9% and 5.8 to 6.6%, respectively. Assay accuracy was better than 93.4%. The assay was used to estimate the pharmacokinetics of glibenclamide after oral administration of a 5 mg tablet of glibenclamide to 18 healthy volunteers.

  6. Validation of quantitative method for azoxystrobin residues in green beans and peas.

    PubMed

    Abdelraheem, Ehab M H; Hassan, Sayed M; Arief, Mohamed M H; Mohammad, Somaia G

    2015-09-01

    This study presents a method validation for extraction and quantitative analysis of azoxystrobin residues in green beans and peas using HPLC-UV and the results confirmed by GC-MS. The employed method involved initial extraction with acetonitrile after the addition of salts (magnesium sulfate and sodium chloride), followed by a cleanup step by activated neutral carbon. Validation parameters; linearity, matrix effect, LOQ, specificity, trueness and repeatability precision were attained. The spiking levels for the trueness and the precision experiments were (0.1, 0.5, 3 mg/kg). For HPLC-UV analysis, mean recoveries ranged between 83.69% to 91.58% and 81.99% to 107.85% for green beans and peas, respectively. For GC-MS analysis, mean recoveries ranged from 76.29% to 94.56% and 80.77% to 100.91% for green beans and peas, respectively. According to these results, the method has been proven to be efficient for extraction and determination of azoxystrobin residues in green beans and peas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Soft network composite materials with deterministic and bio-inspired designs

    PubMed Central

    Jang, Kyung-In; Chung, Ha Uk; Xu, Sheng; Lee, Chi Hwan; Luan, Haiwen; Jeong, Jaewoong; Cheng, Huanyu; Kim, Gwang-Tae; Han, Sang Youn; Lee, Jung Woo; Kim, Jeonghyun; Cho, Moongee; Miao, Fuxing; Yang, Yiyuan; Jung, Han Na; Flavin, Matthew; Liu, Howard; Kong, Gil Woo; Yu, Ki Jun; Rhee, Sang Il; Chung, Jeahoon; Kim, Byunggik; Kwak, Jean Won; Yun, Myoung Hee; Kim, Jin Young; Song, Young Min; Paik, Ungyu; Zhang, Yihui; Huang, Yonggang; Rogers, John A.

    2015-01-01

    Hard and soft structural composites found in biology provide inspiration for the design of advanced synthetic materials. Many examples of bio-inspired hard materials can be found in the literature; far less attention has been devoted to soft systems. Here we introduce deterministic routes to low-modulus thin film materials with stress/strain responses that can be tailored precisely to match the non-linear properties of biological tissues, with application opportunities that range from soft biomedical devices to constructs for tissue engineering. The approach combines a low-modulus matrix with an open, stretchable network as a structural reinforcement that can yield classes of composites with a wide range of desired mechanical responses, including anisotropic, spatially heterogeneous, hierarchical and self-similar designs. Demonstrative application examples in thin, skin-mounted electrophysiological sensors with mechanics precisely matched to the human epidermis and in soft, hydrogel-based vehicles for triggered drug release suggest their broad potential uses in biomedical devices. PMID:25782446

  8. Non-linear matter power spectrum covariance matrix errors and cosmological parameter uncertainties

    NASA Astrophysics Data System (ADS)

    Blot, L.; Corasaniti, P. S.; Amendola, L.; Kitching, T. D.

    2016-06-01

    The covariance of the matter power spectrum is a key element of the analysis of galaxy clustering data. Independent realizations of observational measurements can be used to sample the covariance, nevertheless statistical sampling errors will propagate into the cosmological parameter inference potentially limiting the capabilities of the upcoming generation of galaxy surveys. The impact of these errors as function of the number of realizations has been previously evaluated for Gaussian distributed data. However, non-linearities in the late-time clustering of matter cause departures from Gaussian statistics. Here, we address the impact of non-Gaussian errors on the sample covariance and precision matrix errors using a large ensemble of N-body simulations. In the range of modes where finite volume effects are negligible (0.1 ≲ k [h Mpc-1] ≲ 1.2), we find deviations of the variance of the sample covariance with respect to Gaussian predictions above ˜10 per cent at k > 0.3 h Mpc-1. Over the entire range these reduce to about ˜5 per cent for the precision matrix. Finally, we perform a Fisher analysis to estimate the effect of covariance errors on the cosmological parameter constraints. In particular, assuming Euclid-like survey characteristics we find that a number of independent realizations larger than 5000 is necessary to reduce the contribution of sampling errors to the cosmological parameter uncertainties at subpercent level. We also show that restricting the analysis to large scales k ≲ 0.2 h Mpc-1 results in a considerable loss in constraining power, while using the linear covariance to include smaller scales leads to an underestimation of the errors on the cosmological parameters.

  9. Performance evaluation of the Sysmex(®) XP-300 in an oncology setting: evaluation and comparison of hematological parameters with the Sysmex(®) XN-3000.

    PubMed

    van Dievoet, M A; Louagie, H; Ghys, T

    2016-10-01

    The Sysmex XP-300(®) (XP-300) is a new, fully automated hematology analyzer, designed to generate complete blood counts (CBC) with 3-part differential. In our study, the XP-300 was evaluated as a point-of-care (POC) analyzer in an oncology setting. In which blood samples from patients with different pathologies and treatments, affecting hematopoiesis, were analyzed. Performance was evaluated according to the International Council for Standardization in Haematology (ICSH) guidelines and CLSI protocol H20-A2 . Beside precision, linearity and carry-over, a comparison study with the Sysmex(®) XN-3000 (XN-3000) and a manual reference leukocyte differential was performed. Flagging performance was also evaluated. XP-300 showed excellent precision and linearity results. For within- and between-run precision, the criteria, according to Ricos et al. , were met for all parameters tested, except for platelets in the low level. Less than or equal to 0.5% carry-over was seen for all parameters tested. Comparison studies showed an acceptable correlation with both XN-3000 and the manual reference leukocyte count. A suboptimal flagging performance was demonstrated. In the context of diagnosing cytopenia due to myelosuppressing agents or leukocytosis due to infection, the XP-300 showed good analytical performance. However, in the thrombocytopenic range, precision was suboptimal. In follow-up of hematological malignancies with the occurrence of abnormal cells, we advise verification with a more advanced analyzer or with microscopic review, although further studies with a higher prevalence of abnormal cells are needed. © 2016 John Wiley & Sons Ltd.

  10. A linear refractive photovoltaic concentrator solar array flight experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, P.A.; Murphy, D.M.; Piszczor, M.F.

    1995-12-31

    Concentrator arrays deliver a number of generic benefits for space including high array efficiency, protection from space radiation effects, and minimized plasma interactions. The line focus concentrator concept delivers two added advantages: (1) low-cost mass production of the lens material and, (2) relaxation of precise array tracking requirements to only a single axis. New array designs emphasize lightweight, high stiffness, stow-ability and ease of manufacture and assembly. The linear refractive concentrator can be designed to provide an essentially flat response over a wide range of longitudinal pointing errors for satellites having only single-axis tracking capability. In this paper the authorsmore » address the current status of the SCARLET linear concentrator program with special emphasis on hardware development of an array-level linear refractive concentrator flight experiment. An aggressive, 6-month development and flight validation program, sponsored by the Ballistic Missile Defense Organization (BMDO) and NASA Lewis Research Center, will quantify and verify SCARLET benefits with in-orbit performance measurements.« less

  11. A Linear Variable-[theta] Model for Measuring Individual Differences in Response Precision

    ERIC Educational Resources Information Center

    Ferrando, Pere J.

    2011-01-01

    Models for measuring individual response precision have been proposed for binary and graded responses. However, more continuous formats are quite common in personality measurement and are usually analyzed with the linear factor analysis model. This study extends the general Gaussian person-fluctuation model to the continuous-response case and…

  12. Realizing Broadband and Invertible Linear-to-circular Polarization Converter with Ultrathin Single-layer Metasurface

    PubMed Central

    Li, Zhancheng; Liu, Wenwei; Cheng, Hua; Chen, Shuqi; Tian, Jianguo

    2015-01-01

    The arbitrary control of the polarization states of light has attracted the interest of the scientific community because of the wide range of modern optical applications that such control can afford. However, conventional polarization control setups are bulky and very often operate only within a narrow wavelength range, thereby resisting optical system miniaturization and integration. Here, we present the basic theory, simulated demonstration, and in-depth analysis of a high-performance broadband and invertible linear-to-circular (LTC) polarization converter composed of a single-layer gold nanorod array with a total thickness of ~λ/70 for the near-infrared regime. This setup can transform a circularly polarized wave into a linearly polarized one or a linearly polarized wave with a wavelength-dependent electric field polarization angle into a circularly polarized one in the transmission mode. The broadband and invertible LTC polarization conversion can be attributed to the tailoring of the light interference at the subwavelength scale via the induction of the anisotropic optical resonance mode. This ultrathin single-layer metasurface relaxes the high-precision requirements of the structure parameters in general metasurfaces while retaining the polarization conversion performance. Our findings open up intriguing possibilities towards the realization of novel integrated metasurface-based photonics devices for polarization manipulation, modulation, and phase retardation. PMID:26667360

  13. Development and validation of a new HPLC-UV method for the simultaneous determination of triclabendazole and ivermectin B1a in a pharmaceutical formulation.

    PubMed

    Shurbaji, Maher; Abu Al Rub, Mohamad H; Saket, Munib M; Qaisi, Ali M; Salim, Maher L; Abu-Nameh, Eyad S M

    2010-01-01

    A rapid, simple, and sensitive RP-HPLC analytical method was developed for the simultaneous determination of triclabendazole and ivermectin in combination using a C18 RP column. The mobile phase was acetonitrile-methanol-water-acetic acid (56 + 36 + 7.5 + 0.5, v/v/v/v) at a pH of 4.35 and flow rate of 1.0 mL/min. A 245 nm UV detection wavelength was used. Complete validation, including linearity, accuracy, recovery, LOD, LOQ, precision, robustness, stability, and peak purity, was performed. The calibration curve was linear over the range 50.09-150.26 microg/mL for triclabendazole with r = 0.9999 and 27.01-81.02 microg/mL for ivermectin with r = 0.9999. Calculated LOD and LOQ for triclabendazole were 0.03 and 0.08 microg/mL, respectively, and for ivermectin 0.07 and 0.20 microg/mL, respectively. The intraday precision obtained was 98.71% with RSD of 0.87% for triclabendazole and 100.79% with RSD 0.73% for ivermectin. The interday precision obtained was 99.51% with RSD of 0.35% for triclabendazole and 100.55% with RSD of 0.59% for ivermectin. Robustness was also studied, and there was no significant variation of the system suitability of the analytical method with small changes in experimental parameters.

  14. Use of experimental design for optimisation of the cold plasma ICP-MS determination of lithium, aluminum and iron in soft drinks and alcoholic beverages.

    PubMed

    Bianchi, F; Careri, M; Maffini, M; Mangia, A; Mucchino, C

    2003-01-01

    A sensitive method for the simultaneous determination of (7)Li, (27)Al and (56)Fe by cold plasma ICP-MS was developed and validated. Experimental design was used to investigate the effects of torch position, torch power, lens 2 voltage, and coolant flow. Regression models and desirability functions were applied to find the experimental conditions providing the highest global sensitivity in a multi-elemental analysis. Validation was performed in terms of limits of detection (LOD), limits of quantitation (LOQ), linearity and precision. LODs were 1.4 and 159 ng L(-1) for (7)Li and (56)Fe, respectively; the highest LOD found being that for (27)Al (425 ng L(-1)). Linear ranges of 5 orders of magnitude for Li and 3 orders for Fe were statistically verified for each compound. Precision was evaluated by testing two concentration levels, and good results in terms of both intra-day repeatability and intermediate precision were obtained. RSD values lower than 4.8% at the lowest concentration level were calculated for intra-day repeatability. Commercially available soft drinks and alcoholic beverages contained in different packaging materials (TetraPack, polyethylene terephthalate (PET), commercial cans and glass) were analysed, and all the analytes were detected and quantitated. Copyright 2002 John Wiley & Sons, Ltd.

  15. The Too-Much-Precision Effect.

    PubMed

    Loschelder, David D; Friese, Malte; Schaerer, Michael; Galinsky, Adam D

    2016-12-01

    Past research has suggested a fundamental principle of price precision: The more precise an opening price, the more it anchors counteroffers. The present research challenges this principle by demonstrating a too-much-precision effect. Five experiments (involving 1,320 experts and amateurs in real-estate, jewelry, car, and human-resources negotiations) showed that increasing the precision of an opening offer had positive linear effects for amateurs but inverted-U-shaped effects for experts. Anchor precision backfired because experts saw too much precision as reflecting a lack of competence. This negative effect held unless first movers gave rationales that boosted experts' perception of their competence. Statistical mediation and experimental moderation established the critical role of competence attributions. This research disentangles competing theoretical accounts (attribution of competence vs. scale granularity) and qualifies two putative truisms: that anchors affect experts and amateurs equally, and that more precise prices are linearly more potent anchors. The results refine current theoretical understanding of anchoring and have significant implications for everyday life.

  16. Pore-Environment Engineering with Multiple Metal Sites in Rare-Earth Porphyrinic Metal-Organic Frameworks.

    PubMed

    Zhang, Liangliang; Yuan, Shuai; Feng, Liang; Guo, Bingbing; Qin, Jun-Sheng; Xu, Ben; Lollar, Christina; Sun, Daofeng; Zhou, Hong-Cai

    2018-04-23

    Multi-component metal-organic frameworks (MOFs) with precisely controlled pore environments are highly desired owing to their potential applications in gas adsorption, separation, cooperative catalysis, and biomimetics. A series of multi-component MOFs, namely PCN-900(RE), were constructed from a combination of tetratopic porphyrinic linkers, linear linkers, and rare-earth hexanuclear clusters (RE 6 ) under the guidance of thermodynamics. These MOFs exhibit high surface areas (up to 2523 cm 2  g -1 ) and unlimited tunability by modification of metal nodes and/or linker components. Post-synthetic exchange of linear linkers and metalation of two organic linkers were realized, allowing the incorporation of a wide range of functional moieties. Two different metal sites were sequentially placed on the linear linker and the tetratopic porphyrinic linker, respectively, giving rise to an ideal platform for heterogeneous catalysis. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bose, Benjamin; Koyama, Kazuya, E-mail: benjamin.bose@port.ac.uk, E-mail: kazuya.koyama@port.ac.uk

    We develop a code to produce the power spectrum in redshift space based on standard perturbation theory (SPT) at 1-loop order. The code can be applied to a wide range of modified gravity and dark energy models using a recently proposed numerical method by A.Taruya to find the SPT kernels. This includes Horndeski's theory with a general potential, which accommodates both chameleon and Vainshtein screening mechanisms and provides a non-linear extension of the effective theory of dark energy up to the third order. Focus is on a recent non-linear model of the redshift space power spectrum which has been shownmore » to model the anisotropy very well at relevant scales for the SPT framework, as well as capturing relevant non-linear effects typical of modified gravity theories. We provide consistency checks of the code against established results and elucidate its application within the light of upcoming high precision RSD data.« less

  18. Perceptual scale expansion: an efficient angular coding strategy for locomotor space.

    PubMed

    Durgin, Frank H; Li, Zhi

    2011-08-01

    Whereas most sensory information is coded on a logarithmic scale, linear expansion of a limited range may provide a more efficient coding for the angular variables important to precise motor control. In four experiments, we show that the perceived declination of gaze, like the perceived orientation of surfaces, is coded on a distorted scale. The distortion seems to arise from a nearly linear expansion of the angular range close to horizontal/straight ahead and is evident in explicit verbal and nonverbal measures (Experiments 1 and 2), as well as in implicit measures of perceived gaze direction (Experiment 4). The theory is advanced that this scale expansion (by a factor of about 1.5) may serve a functional goal of coding efficiency for angular perceptual variables. The scale expansion of perceived gaze declination is accompanied by a corresponding expansion of perceived optical slants in the same range (Experiments 3 and 4). These dual distortions can account for the explicit misperception of distance typically obtained by direct report and exocentric matching, while allowing for accurate spatial action to be understood as the result of calibration.

  19. Perceptual Scale Expansion: An Efficient Angular Coding Strategy for Locomotor Space

    PubMed Central

    Durgin, Frank H.; Li, Zhi

    2011-01-01

    Whereas most sensory information is coded in a logarithmic scale, linear expansion of a limited range may provide a more efficient coding for angular variables important to precise motor control. In four experiments it is shown that the perceived declination of gaze, like the perceived orientation of surfaces is coded on a distorted scale. The distortion seems to arise from a nearly linear expansion of the angular range close to horizontal/straight ahead and is evident in explicit verbal and non-verbal measures (Experiments 1 and 2) and in implicit measures of perceived gaze direction (Experiment 4). The theory is advanced that this scale expansion (by a factor of about 1.5) may serve a functional goal of coding efficiency for angular perceptual variables. The scale expansion of perceived gaze declination is accompanied by a corresponding expansion of perceived optical slants in the same range (Experiments 3 and 4). These dual distortions can account for the explicit misperception of distance typically obtained by direct report and exocentric matching while allowing accurate spatial action to be understood as the result of calibration. PMID:21594732

  20. Structural design of off-axis aspheric surface reflective zoom optical system

    NASA Astrophysics Data System (ADS)

    Zhang, Ke; Chang, Jun; Song, Haiping; Niu, Yajun

    2018-01-01

    Designed an off-axis aspheric reflective zoom optical system, and produced a prototype. The system consists of three aspheric reflective lens, the zoom range is 30mm { 90mm. This system gave up the traditional structure of zoom cam, the lens moved using linear guide rail driven by motor, the positioning precision of which was 0.01mm. And introduced the design of support frames of each lens. The practice tests verified the rationality of the prototype structure design.

  1. Solution for the nonuniformity correction of infrared focal plane arrays.

    PubMed

    Zhou, Huixin; Liu, Shangqian; Lai, Rui; Wang, Dabao; Cheng, Yubao

    2005-05-20

    Based on the S-curve model of the detector response of infrared focal plan arrays (IRFPAs), an improved two-point correction algorithm is presented. The algorithm first transforms the nonlinear image data into linear data and then uses the normal two-point algorithm to correct the linear data. The algorithm can effectively overcome the influence of nonlinearity of the detector's response, and it enlarges the correction precision and the dynamic range of the response. A real-time imaging-signal-processing system for IRFPAs that is based on a digital signal processor and field-programmable gate arrays is also presented. The nonuniformity correction capability of the presented solution is validated by experimental imaging procedures of a 128 x 128 pixel IRFPA camera prototype.

  2. Earth fissures and localized differential subsidence

    USGS Publications Warehouse

    Holzer, Thomas L.; Pampeyan, Earl H.

    1981-01-01

    Long linear tension cracks associated with declining groundwater levels at four sites in subsiding areas in south-central Arizona, Fremont Valley, California, and Las Vegas Valley, Nevada, occur near points of maximum convex-upward curvature in subsidence profiles oriented perpendicular to the cracks. Profiles are based on repeated precise vertical control surveys of lines of closely spaced bench marks. Association of these fissures with zones of localized differential subsidence indicates that linear earth fissures are caused by horizontal tensile strains probably resulting from localized differential compaction. Horizontal tensile strains across the fissures at the point of maximum convex-upward curvature, ranging from approximately 100 to 700 microstrains (0.01 to 0.07% per year), were indicated based on measurements with a tape or electronic distance meter.

  3. Linear vs non-linear QCD evolution in the neutrino-nucleon cross section

    NASA Astrophysics Data System (ADS)

    Albacete, Javier L.; Illana, José I.; Soto-Ontoso, Alba

    2016-03-01

    Evidence for an extraterrestrial flux of ultra-high-energy neutrinos, in the order of PeV, has opened a new era in Neutrino Astronomy. An essential ingredient for the determination of neutrino fluxes from the number of observed events is the precise knowledge of the neutrino-nucleon cross section. In this work, based on [1], we present a quantitative study of σνN in the neutrino energy range 104 < Eν < 1014 GeV within two transversal QCD approaches: NLO DGLAP evolution using different sets of PDFs and BK small-x evolution with running coupling and kinematical corrections. Further, we translate this theoretical uncertainty into upper bounds for the ultra-high-energy neutrino flux for different experiments.

  4. A 41 ps ASIC time-to-digital converter for physics experiments

    NASA Astrophysics Data System (ADS)

    Russo, Stefano; Petra, Nicola; De Caro, Davide; Barbarino, Giancarlo; Strollo, Antonio G. M.

    2011-12-01

    We present a novel Time-to-Digital (TDC) converter for physics experiments. Proposed TDC is based on a synchronous counter and an asynchronous fine interpolator. The fine part of the measurement is obtained using NORA inverters that provide improved resolution. A prototype IC was fabricated in 180 nm CMOS technology. Experimental measurements show that proposed TDC features 41 ps resolution associated with 0.35LSB differential non-linearity, 0.77LSB integral non-linearity and a negligible single shot precision. The whole dynamic range is equal to 18 μs. The proposed TDC is designed using a flash architecture that reduces dead time. Data reported in the paper show that our design is well suited for present and future particle physics experiments.

  5. Development and Validation of Stability-Indicating Derivative Spectrophotometric Methods for Determination of Dronedarone Hydrochloride

    NASA Astrophysics Data System (ADS)

    Chadha, R.; Bali, A.

    2016-05-01

    Rapid, sensitive, cost effective and reproducible stability-indicating derivative spectrophotometric methods have been developed for the estimation of dronedarone HCl employing peak-zero (P-0) and peak-peak (P-P) techniques, and their stability-indicating potential assessed in forced degraded solutions of the drug. The methods were validated with respect to linearity, accuracy, precision and robustness. Excellent linearity was observed in concentrations 2-40 μg/ml ( r 2 = 0.9986). LOD and LOQ values for the proposed methods ranged from 0.42-0.46 μg/ml and 1.21-1.27 μg/ml, respectively, and excellent recovery of the drug was obtained in the tablet samples (99.70 ± 0.84%).

  6. Study on fluorescence characteristics of duloxetine hydrochloride

    NASA Astrophysics Data System (ADS)

    Liu, Xiangping; Du, Yingxiang; Wu, Xiulan

    2008-12-01

    The fluorescence characteristics of duloxetine hydrochloride are studied in this paper. The fluorescence emission spectra of duloxetine demonstrate that intramolecular charge-transfer takes place between thiophene ring and napthalenyloxy group upon irradiation. The effects of excitation light, solvent system, variation of solution pH value, metal ions and vitamin C on the fluorescence spectra of duloxetine hydrochloride are elucidated, respectively. A spectrofluorometric method of quantitative determination of duloxetine in dosage form is reported for the first time, the linear range is 7.14 × 10 -8 mol/L to 1.43 × 10 -5 mol/L, the linear correlation coefficient r is equal to 0.9997, and the detection limit is 3.5 × 10 -8 mol/L. The accuracy and the precision are satisfactory.

  7. Determination of d-limonene in adipose tissue by gas chromatography-mass spectrometry

    PubMed Central

    Miller, Jessica A.; Hakim, Iman A.; Thomson, Cynthia; Thompson, Patricia; Chow, H-H. Sherry

    2008-01-01

    We developed a novel method for analyzing d-limonene levels in adipose tissue. Fat samples were subjected to saponification followed by solvent extraction. d-Limonene in the sample extract was analyzed using gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring. Linear calibration curves were established over the mass range of 79.0-2,529 ng d-limonene per 0.1 grams of adipose tissue. Satisfactory within day precision (RSD 6.7 to 9.6%) and accuracy (% difference of −2.7 to 3.8%) and between day precision (RSD 6.0 to 10.7%) and accuracy (% difference of 1.8 to 2.6%) were achieved. The assay was successfully applied to human fat biopsy samples from a d-limonene feeding trial. PMID:18571481

  8. A cautionary tale: The Coulomb modified ANC for the 1/2+ 2 state in 17O

    NASA Astrophysics Data System (ADS)

    Keeley, N.; Kemper, K. W.; Rusek, K.

    2018-05-01

    We discuss the impact of the uncertainty (± 8 keV) in the excitation energy of the astrophysically important 6.356 MeV 1/2+2 state of 17O on the precision with which the Coulomb reduced ANC (\\widetilde{C}) for the < ^{17}O (1/2^+_2) | {}^{13}C + α> overlap can be extracted from direct reaction data. We find a linear dependence of \\widetilde{C}2 on the binding energy, the value extracted varying by a factor of 4 over the range E_{ex} = 6.356-6.348 MeV. This represents an intrinsic limit on the precision with which \\widetilde{C}2 can be determined which cannot be improved unless or until the uncertainty in E_{ex} is reduced.

  9. Method development and validation of potent pyrimidine derivative by UV-VIS spectrophotometer.

    PubMed

    Chaudhary, Anshu; Singh, Anoop; Verma, Prabhakar Kumar

    2014-12-01

    A rapid and sensitive ultraviolet-visible (UV-VIS) spectroscopic method was developed for the estimation of pyrimidine derivative 6-Bromo-3-(6-(2,6-dichlorophenyl)-2-(morpolinomethylamino) pyrimidine4-yl) -2H-chromen-2-one (BT10M) in bulk form. Pyrimidine derivative was monitored at 275 nm with UV detection, and there is no interference of diluents at 275 nm. The method was found to be linear in the range of 50 to 150 μg/ml. The accuracy and precision were determined and validated statistically. The method was validated as a guideline. The results showed that the proposed method is suitable for the accurate, precise, and rapid determination of pyrimidine derivative. Graphical Abstract Method development and validation of potent pyrimidine derivative by UV spectroscopy.

  10. Mars entry guidance based on an adaptive reference drag profile

    NASA Astrophysics Data System (ADS)

    Liang, Zixuan; Duan, Guangfei; Ren, Zhang

    2017-08-01

    The conventional Mars entry tracks a fixed reference drag profile (FRDP). To improve the landing precision, a novel guidance approach that utilizes an adaptive reference drag profile (ARDP) is presented. The entry flight is divided into two phases. For each phase, a family of drag profiles corresponding to various trajectory lengths is planned. Two update windows are investigated for the reference drag profile. At each window, the ARDP is selected online from the profile database according to the actual range-to-go. The tracking law for the selected drag profile is designed based on the feedback linearization. Guidance approaches using the ARDP and the FRDP are then tested and compared. Simulation results demonstrate that the proposed ARDP approach achieves much higher guidance precision than the conventional FRDP approach.

  11. Development of an automatic test equipment for nano gauging displacement transducers

    NASA Astrophysics Data System (ADS)

    Wang, Yung-Chen; Jywe, Wen-Yuh; Liu, Chien-Hung

    2005-01-01

    In order to satisfy the increasing demands on the precision in manufacturing technology, nanaometrology gradually becomes more important in manufacturing process. To ensure the precision of manufacture, precise measuring instruments and sensors play a decesive role for the accurate characterization and inspection of products. For linear length inspection, high precision gauging displacement transducers, i.e. nano gauging displacement transducers (NGDT), have been often utilized, which have been often utilized, which have the resolution in the nanometer range and can achieve an accuracy of less than 100 nm. Such measurement instruments include transducers based on electronic as well as optical measurement principles, e.g. inductive, incremental-optical or interference optical. To guarantee the accuracy and the traceability to the definition of the meter, calibration and test of NGDT are essential. Currently, there are some methods and machines for test of NGDT, but they suffer from various disadvantages. Some of them permit only manual test procedures which are time-consuming, e.g. with high accurate gauge blocks as material measures. Other tests can reach higher accuracy only in the micrometer range or result in uncertainties of more than 100 nm in the large measuring ranges. To realize the test of NGDT with a high resolution as well as a large measuring range, an automatic test equipment was constructed, that has a resolution of 1.24 nm, a measuring range of up to 20 nm (60 mm) and a measuring uncertainty of approximate ±10 nm can fulfil the requirements of high resolution within the nanometer range while simultaneously covering a large measuring range in the order of millimeters. The test system includes a stable frame, a polarization interferometer, an angle sensor, an angular control, a drive system and piezo translators. During the test procedure, the angular control and piezo translators minimize the Abbe error. For the automation of the test procedure a measuring program adhering to the measurement principle outlined in VDI/VDE 2617 guidelines was designed. With this program NGDT can be tested in less than thirty minutes with eleven measuring points and five repetitions. By mean of theoretical and experimental investigations it can be proved that the automatic test system achieves a test uncertainty of approx. ±10 nm at the measuring range of 18 mm, that corresponds to a relative uncertainty of approximately ±5 × 10-7. With small uncertainty, the minimization of the Abbe error and short test time, this system can be regarded as a universal and efficient precision test equipment, which is available for the accurate test of arbitrary high precision gauging displacement transducers.

  12. Precise Lamb Shift Measurements in Hydrogen-Like Heavy Ions—Status and Perspectives

    NASA Astrophysics Data System (ADS)

    Andrianov, V.; Beckert, K.; Bleile, A.; Chatterjee, Ch.; Echler, A.; Egelhof, P.; Gumberidze, A.; Ilieva, S.; Kiselev, O.; Kilbourne, C.; Kluge, H.-J.; Kraft-Bermuth, S.; McCammon, D.; Meier, J. P.; Reuschl, R.; Stöhlker, T.; Trassinelli, M.

    2009-12-01

    The precise determination of the energy of the Lyman α1 and α2 lines in hydrogen-like heavy ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields. For the first time, a calorimetric low-temperature detector was applied in an experiment to precisely determine the transition energy of the Lyman lines of lead ions 207Pb81+ at the Experimental Storage Ring (ESR) at GSI. The detectors consist of silicon thermistors, provided by the NASA/Goddard Space Flight Center, and Pb or Sn absorbers to obtain high quantum efficiency in the energy range of 40-80 keV, where the Doppler-shifted Lyman lines are located. The measured energy of the Lyman α1 line, E(Ly-α1, 207Pb81+) = (77937±12stat±23syst) eV, agrees within errors with theoretical predictions. The systematic error is mainly due to uncertainties in the non-linear energy calibration of the detectors as well as the relative position of detector and gas-jet target.

  13. Time-resolved optical spectrometer based on a monolithic array of high-precision TDCs and SPADs

    NASA Astrophysics Data System (ADS)

    Tamborini, Davide; Markovic, Bojan; Di Sieno, Laura; Contini, Davide; Bassi, Andrea; Tisa, Simone; Tosi, Alberto; Zappa, Franco

    2013-12-01

    We present a compact time-resolved spectrometer suitable for optical spectroscopy from 400 nm to 1 μm wavelengths. The detector consists of a monolithic array of 16 high-precision Time-to-Digital Converters (TDC) and Single-Photon Avalanche Diodes (SPAD). The instrument has 10 ps resolution and reaches 70 ps (FWHM) timing precision over a 160 ns full-scale range with a Differential Non-Linearity (DNL) better than 1.5 % LSB. The core of the spectrometer is the application-specific integrated chip composed of 16 pixels with 250 μm pitch, containing a 20 μm diameter SPAD and an independent TDC each, fabricated in a 0.35 μm CMOS technology. In front of this array a monochromator is used to focus different wavelengths into different pixels. The spectrometer has been used for fluorescence lifetime spectroscopy: 5 nm spectral resolution over an 80 nm bandwidth is achieved. Lifetime spectroscopy of Nile blue is demonstrated.

  14. Quantitative analysis of the immunosuppressant CP-690,550 in whole blood by column-switching high-performance liquid chromatography and mass spectrometry detection.

    PubMed

    Paniagua, Ricardo; Campbell, Andrew; Changelian, Paul S; Reitz, Bruce A; Prakash, Chandra; Borie, Dominic C

    2005-10-01

    A fast and accurate method to quantify the new immunosuppressive JAK3 inhibitor CP-690,550 in whole blood using a dual-pump liquid chromatography-liquid chromatography-mass spectrometry (LC/LC-MS) system was developed and validated in nonhuman primate blood. Before injection, blood samples were prepared by precipitation with a reagent that included methanol and acetonitrile (30:70, vol/vol) along with the internal standard (CP-istd). Column-switching LC/LC-MS analysis used online extraction followed by separation on a C8 analytic column and MS detection of the [M + H] CP-690,550 (m/z = 313.1) and CP internal standard (m/z = 288.1). Linearity was always better than r = 0.99 (n = 7) for CP-690,550 (range 2.5-750 ng/mL), with a lower limit of quantification (LLOQ) of 2.5 ng/mL. The intrarun accuracy and precision ranged from 103.0% to 105.4% and 2.7% to 4.3%, respectively (n = 5), and the interday precision ranged from 8.7% to 11.1%, and the interday accuracy ranged from 98.1% to 103.8% of nominal values (n = 14). The injection repeatability for the method was 1.3% (n = 7). Except for the LLOQ, the intraday accuracy and precision in human blood were also within 15% (n = 5). The combination of simple sample preparation and short analytic run time of this sensitive procedure makes it effective for monitoring the concentration of CP-690,550 in whole blood in organ-transplant recipients.

  15. Multiple Reaction Monitoring Enables Precise Quantification of 97 Proteins in Dried Blood Spots*

    PubMed Central

    Chambers, Andrew G.; Percy, Andrew J.; Yang, Juncong; Borchers, Christoph H.

    2015-01-01

    The dried blood spot (DBS) methodology provides a minimally invasive approach to sample collection and enables room-temperature storage for most analytes. DBS samples have successfully been analyzed by liquid chromatography multiple reaction monitoring mass spectrometry (LC/MRM-MS) to quantify a large range of small molecule biomarkers and drugs; however, this strategy has only recently been explored for MS-based proteomics applications. Here we report the development of a highly multiplexed MRM assay to quantify endogenous proteins in human DBS samples. This assay uses matching stable isotope-labeled standard peptides for precise, relative quantification, and standard curves to characterize the analytical performance. A total of 169 peptides, corresponding to 97 proteins, were quantified in the final assay with an average linear dynamic range of 207-fold and an average R2 value of 0.987. The total range of this assay spanned almost 5 orders of magnitude from serum albumin (P02768) at 18.0 mg/ml down to cholinesterase (P06276) at 190 ng/ml. The average intra-assay and inter-assay precision for 6 biological samples ranged from 6.1–7.5% CV and 9.5–11.0% CV, respectively. The majority of peptide targets were stable after 154 days at storage temperatures from −20 °C to 37 °C. Furthermore, protein concentration ratios between matching DBS and whole blood samples were largely constant (<20% CV) across six biological samples. This assay represents the highest multiplexing yet achieved for targeted protein quantification in DBS samples and is suitable for biomedical research applications. PMID:26342038

  16. Multitarget, quantitative nanoplasmonic electrical field-enhanced resonating device (NE2RD) for diagnostics.

    PubMed

    Inci, Fatih; Filippini, Chiara; Baday, Murat; Ozen, Mehmet Ozgun; Calamak, Semih; Durmus, Naside Gozde; Wang, ShuQi; Hanhauser, Emily; Hobbs, Kristen S; Juillard, Franceline; Kuang, Ping Ping; Vetter, Michael L; Carocci, Margot; Yamamoto, Hidemi S; Takagi, Yuko; Yildiz, Umit Hakan; Akin, Demir; Wesemann, Duane R; Singhal, Amit; Yang, Priscilla L; Nibert, Max L; Fichorova, Raina N; Lau, Daryl T-Y; Henrich, Timothy J; Kaye, Kenneth M; Schachter, Steven C; Kuritzkes, Daniel R; Steinmetz, Lars M; Gambhir, Sanjiv S; Davis, Ronald W; Demirci, Utkan

    2015-08-11

    Recent advances in biosensing technologies present great potential for medical diagnostics, thus improving clinical decisions. However, creating a label-free general sensing platform capable of detecting multiple biotargets in various clinical specimens over a wide dynamic range, without lengthy sample-processing steps, remains a considerable challenge. In practice, these barriers prevent broad applications in clinics and at patients' homes. Here, we demonstrate the nanoplasmonic electrical field-enhanced resonating device (NE(2)RD), which addresses all these impediments on a single platform. The NE(2)RD employs an immunodetection assay to capture biotargets, and precisely measures spectral color changes by their wavelength and extinction intensity shifts in nanoparticles without prior sample labeling or preprocessing. We present through multiple examples, a label-free, quantitative, portable, multitarget platform by rapidly detecting various protein biomarkers, drugs, protein allergens, bacteria, eukaryotic cells, and distinct viruses. The linear dynamic range of NE(2)RD is five orders of magnitude broader than ELISA, with a sensitivity down to 400 fg/mL This range and sensitivity are achieved by self-assembling gold nanoparticles to generate hot spots on a 3D-oriented substrate for ultrasensitive measurements. We demonstrate that this precise platform handles multiple clinical samples such as whole blood, serum, and saliva without sample preprocessing under diverse conditions of temperature, pH, and ionic strength. The NE(2)RD's broad dynamic range, detection limit, and portability integrated with a disposable fluidic chip have broad applications, potentially enabling the transition toward precision medicine at the point-of-care or primary care settings and at patients' homes.

  17. Multitarget, quantitative nanoplasmonic electrical field-enhanced resonating device (NE2RD) for diagnostics

    PubMed Central

    Inci, Fatih; Filippini, Chiara; Ozen, Mehmet Ozgun; Calamak, Semih; Durmus, Naside Gozde; Wang, ShuQi; Hanhauser, Emily; Hobbs, Kristen S.; Juillard, Franceline; Kuang, Ping Ping; Vetter, Michael L.; Carocci, Margot; Yamamoto, Hidemi S.; Takagi, Yuko; Yildiz, Umit Hakan; Akin, Demir; Wesemann, Duane R.; Singhal, Amit; Yang, Priscilla L.; Nibert, Max L.; Fichorova, Raina N.; Lau, Daryl T.-Y.; Henrich, Timothy J.; Kaye, Kenneth M.; Schachter, Steven C.; Kuritzkes, Daniel R.; Steinmetz, Lars M.; Gambhir, Sanjiv S.; Davis, Ronald W.; Demirci, Utkan

    2015-01-01

    Recent advances in biosensing technologies present great potential for medical diagnostics, thus improving clinical decisions. However, creating a label-free general sensing platform capable of detecting multiple biotargets in various clinical specimens over a wide dynamic range, without lengthy sample-processing steps, remains a considerable challenge. In practice, these barriers prevent broad applications in clinics and at patients’ homes. Here, we demonstrate the nanoplasmonic electrical field-enhanced resonating device (NE2RD), which addresses all these impediments on a single platform. The NE2RD employs an immunodetection assay to capture biotargets, and precisely measures spectral color changes by their wavelength and extinction intensity shifts in nanoparticles without prior sample labeling or preprocessing. We present through multiple examples, a label-free, quantitative, portable, multitarget platform by rapidly detecting various protein biomarkers, drugs, protein allergens, bacteria, eukaryotic cells, and distinct viruses. The linear dynamic range of NE2RD is five orders of magnitude broader than ELISA, with a sensitivity down to 400 fg/mL This range and sensitivity are achieved by self-assembling gold nanoparticles to generate hot spots on a 3D-oriented substrate for ultrasensitive measurements. We demonstrate that this precise platform handles multiple clinical samples such as whole blood, serum, and saliva without sample preprocessing under diverse conditions of temperature, pH, and ionic strength. The NE2RD’s broad dynamic range, detection limit, and portability integrated with a disposable fluidic chip have broad applications, potentially enabling the transition toward precision medicine at the point-of-care or primary care settings and at patients’ homes. PMID:26195743

  18. Accuracy and Precision in Measurements of Biomass Oxidative Ratio and Carbon Oxidation State

    NASA Astrophysics Data System (ADS)

    Gallagher, M. E.; Masiello, C. A.; Randerson, J. T.; Chadwick, O. A.; Robertson, G. P.

    2007-12-01

    Ecosystem oxidative ratio (OR) is a critical parameter in the apportionment of anthropogenic CO2 between the terrestrial biosphere and ocean carbon reservoirs. OR is the ratio of O2 to CO2 in gas exchange fluxes between the terrestrial biosphere and atmosphere. Ecosystem OR is linearly related to biomass carbon oxidation state (Cox), a fundamental property of the earth system describing the bonding environment of carbon in molecules. Cox can range from -4 to +4 (CH4 to CO2). Variations in both Cox and OR are driven by photosynthesis, respiration, and decomposition. We are developing several techniques to accurately measure variations in ecosystem Cox and OR; these include elemental analysis, bomb calorimetry, and 13C nuclear magnetic resonance spectroscopy. A previous study, comparing the accuracy and precision of elemental analysis versus bomb calorimetry for pure chemicals, showed that elemental analysis-based measurements are more accurate, while calorimetry- based measurements yield more precise data. However, the limited biochemical range of natural samples makes it possible that calorimetry may ultimately prove most accurate, as well as most cost-effective. Here we examine more closely the accuracy of Cox and OR values generated by calorimetry on a large set of natural biomass samples collected from the Kellogg Biological Station-Long Term Ecological Research (KBS-LTER) site in Michigan.

  19. Precision measurements of linear scattering density using muon tomography

    NASA Astrophysics Data System (ADS)

    Åström, E.; Bonomi, G.; Calliari, I.; Calvini, P.; Checchia, P.; Donzella, A.; Faraci, E.; Forsberg, F.; Gonella, F.; Hu, X.; Klinger, J.; Sundqvist Ökvist, L.; Pagano, D.; Rigoni, A.; Ramous, E.; Urbani, M.; Vanini, S.; Zenoni, A.; Zumerle, G.

    2016-07-01

    We demonstrate that muon tomography can be used to precisely measure the properties of various materials. The materials which have been considered have been extracted from an experimental blast furnace, including carbon (coke) and iron oxides, for which measurements of the linear scattering density relative to the mass density have been performed with an absolute precision of 10%. We report the procedures that are used in order to obtain such precision, and a discussion is presented to address the expected performance of the technique when applied to heavier materials. The results we obtain do not depend on the specific type of material considered and therefore they can be extended to any application.

  20. μ-PADs for detection of chemical warfare agents.

    PubMed

    Pardasani, Deepak; Tak, Vijay; Purohit, Ajay K; Dubey, D K

    2012-12-07

    Conventional methods of detection of chemical warfare agents (CWAs) based on chromogenic reactions are time and solvent intensive. The development of cost, time and solvent effective microfluidic paper based analytical devices (μ-PADs) for the detection of nerve and vesicant agents is described. The detection of analytes was based upon their reactions with rhodamine hydroxamate and para-nitrobenzyl pyridine, producing red and blue colours respectively. Reactions were optimized on the μ-PADs to produce the limits of detection (LODs) as low as 100 μM for sulfur mustard in aqueous samples. Results were quantified with the help of a simple desktop scanner and Photoshop software. Sarin achieved a linear response in the two concentration ranges of 20-100 mM and 100-500 mM, whereas the response of sulfur mustard was found to be linear in the concentration range of 10-75 mM. Results were precise enough to establish the μ-PADs as a valuable tool for security personnel fighting against chemical terrorism.

  1. Development and validation of RP-UHPLC procedure for estimation of 5-amino salicyclic acid in 5-amino salicyclic acid rectal suppositories

    NASA Astrophysics Data System (ADS)

    Balaji, Jayagopal; Shivashankar, Murugesh

    2017-11-01

    The present study describes a simple and robust reverse phase ultra performance liquid chromatography (RP-UPLC) method for the quantification of 5-amino salicyclic acid in 5-amino salicyclic acid rectal capsules. Successful separation of Mesalamine peak from excipient peaks and diluent were achieved on a Acquity C8 (50 × 2.1 mm, 1.7 μm) and UV detector at 254 nm, 0.3 mL/min as a flow rate, and 3 μL as an injection volume. For the RP-UPLC method, phosphate buffer and methanol was used as mobile phases at ratio of 83:17 and the column temperature was 25 °C. Percentage recovery obtained in the range of 98.7 - 99.7 % and the method is linear for Mesalamine for specified concentration range with coefficient of variation (r) not less than 0.99. The proposed RP-UPLC method was found to be specific, linear, precise, accurate and robust.

  2. Analysis of Waveform Retracking Methods in Antarctic Ice Sheet Based on CRYOSAT-2 Data

    NASA Astrophysics Data System (ADS)

    Xiao, F.; Li, F.; Zhang, S.; Hao, W.; Yuan, L.; Zhu, T.; Zhang, Y.; Zhu, C.

    2017-09-01

    Satellite altimetry plays an important role in many geoscientific and environmental studies of Antarctic ice sheet. The ranging accuracy is degenerated near coasts or over nonocean surfaces, due to waveform contamination. A postprocess technique, known as waveform retracking, can be used to retrack the corrupt waveform and in turn improve the ranging accuracy. In 2010, the CryoSat-2 satellite was launched with the Synthetic aperture Interferometric Radar ALtimeter (SIRAL) onboard. Satellite altimetry waveform retracking methods are discussed in the paper. Six retracking methods including the OCOG method, the threshold method with 10 %, 25 % and 50 % threshold level, the linear and exponential 5-β parametric methods are used to retrack CryoSat-2 waveform over the transect from Zhongshan Station to Dome A. The results show that the threshold retracker performs best with the consideration of waveform retracking success rate and RMS of retracking distance corrections. The linear 5-β parametric retracker gives best waveform retracking precision, but cannot make full use of the waveform data.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahyuni, Wulan Tri, E-mail: wulantriws@gmail.com; Department of Chemistry, FMIPA, Universitas Indonesia, Kampus UI Depok; Ivandini, Tribidasari A.

    Biomolecule modified magnetic beads has been widely used in separation and sensing process. This study used streptavidin modified magnetic beads to immobilize biotin modified zanamivir. Biotin-streptavidin affinity facilitates immobilization of zanamivir on magnetic beads. Then interaction of zanamivir and neuraminidase was adopted as basic for enzyme detection. Detection of neuraminidase was performed at gold modified BDD using cyclic voltammetry technique. The measurement was carried out based on alteration of electrochemical signals of working electrode as neuraminidase response. The result showed that zanamivir was successfully immobilized on magnetic beads. The optimum amount of magnetic beads for zanamivir immobilization was 120 ug.more » Linear responses of neuraminidase were detected in concentration range of 0-15 mU. Detection limit (LOD) of measurement was 2.32 mU (R2 = 0.959) with precision as % RSD of 1.41%. Measurement of neuraminidase on magnetic beads could be also performed in the presence of mucin matrix. The linearity range was 0-8 mU with LOD of 0.64 mU (R2 = 0.950) and % RSD of 7.25%.« less

  4. Time-to-digital converter card for multichannel time-resolved single-photon counting applications

    NASA Astrophysics Data System (ADS)

    Tamborini, Davide; Portaluppi, Davide; Tisa, Simone; Tosi, Alberto

    2015-03-01

    We present a high performance Time-to-Digital Converter (TDC) card that provides 10 ps timing resolution and 20 ps (rms) timing precision with a programmable full-scale-range from 160 ns to 10 μs. Differential Non-Linearity (DNL) is better than 1.3% LSB (rms) and Integral Non-Linearity (INL) is 5 ps rms. Thanks to the low power consumption (400 mW) and the compact size (78 mm x 28 mm x 10 mm), this card is the building block for developing compact multichannel time-resolved instrumentation for Time-Correlated Single-Photon Counting (TCSPC). The TDC-card outputs the time measurement results together with the rates of START and STOP signals and the number of valid TDC conversions. These additional information are needed by many TCSPC-based applications, such as: Fluorescence Lifetime Imaging (FLIM), Time-of-Flight (TOF) ranging measurements, time-resolved Positron Emission Tomography (PET), single-molecule spectroscopy, Fluorescence Correlation Spectroscopy (FCS), Diffuse Optical Tomography (DOT), Optical Time-Domain Reflectometry (OTDR), quantum optics, etc.

  5. Weighted linear least squares estimation of diffusion MRI parameters: strengths, limitations, and pitfalls.

    PubMed

    Veraart, Jelle; Sijbers, Jan; Sunaert, Stefan; Leemans, Alexander; Jeurissen, Ben

    2013-11-01

    Linear least squares estimators are widely used in diffusion MRI for the estimation of diffusion parameters. Although adding proper weights is necessary to increase the precision of these linear estimators, there is no consensus on how to practically define them. In this study, the impact of the commonly used weighting strategies on the accuracy and precision of linear diffusion parameter estimators is evaluated and compared with the nonlinear least squares estimation approach. Simulation and real data experiments were done to study the performance of the weighted linear least squares estimators with weights defined by (a) the squares of the respective noisy diffusion-weighted signals; and (b) the squares of the predicted signals, which are reconstructed from a previous estimate of the diffusion model parameters. The negative effect of weighting strategy (a) on the accuracy of the estimator was surprisingly high. Multi-step weighting strategies yield better performance and, in some cases, even outperformed the nonlinear least squares estimator. If proper weighting strategies are applied, the weighted linear least squares approach shows high performance characteristics in terms of accuracy/precision and may even be preferred over nonlinear estimation methods. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Stability-indicating method for simultaneous estimation of olmesartan medoxomile, amlodipine besylate and hydrochlorothiazide by RP-HPLC in tablet dosage form.

    PubMed

    Jain, P S; Patel, M K; Gorle, A P; Chaudhari, A J; Surana, S J

    2012-09-01

    A simple, specific, accurate and precise stability-indicating reversed-phase high-performance liquid chromatographic method was developed for simultaneous estimation of olmesartan medoxomile (OLME), amlodipine besylate (AMLO) and hydrochlorothiazide (HCTZ) in tablet dosage form. The method was developed using an RP C18 base deactivated silica column (250 × 4.6 mm, 5 µm) with a mobile phase consisting of triethylamine (pH 3.0) adjusted with orthophosphoric acid (A) and acetonitrile (B), with a timed gradient program of T/%B: 0/30, 7/70, 8/30, 10/30 with a flow rate of 1.4 mL/min. Ultraviolet detection was used at 236 nm. The retention times for OLME, AMLO and HCTZ were found to be 6.72, 4.28 and 2.30, respectively. The proposed method was validated for precision, accuracy, linearity, range, robustness, ruggedness and force degradation study. The calibration curves of OLME, AMLO and HCTZ were linear over the range of 50-150, 12.5-37.5 and 31-93 µg/mL, respectively. The method was found to be sensitive. The limits of detection of OLME, AMLO and HCTZ were determined 0.19, 0.16 and 0.22 µg/mL and limits of quantification of OLME, AMLO and HCTZ were determined 0.57, 0.49 and 0.66, respectively. Forced degradation study was performed according to International Conference on Harmonization guidelines.

  7. Simultaneous determination of triacetin, acetic ether, butyl acetate and amorolfine hydrochloride in amorolfine liniment by HPLC.

    PubMed

    Gao, Yuan; Li, Li; Zhang, Jianjun; Shu, Wenjuan; Gao, Liqiong

    2012-04-01

    A simple, rapid, specific and precise reversed-phase high-performance liquid chromatographic method was developed for simultaneous estimation of triacetin, acetic ether, butyl acetate and amorolfine in marketed pharmaceutical liniment. Chromatographic separation was performed on a Shimadzu VP-ODS C(18) column using the mixture of citric acid-hydrochloric acid-sodium hydrate buffer (pH 3.0), acetonitrile and methanol (32:30:38) as the mobile phase at a flow rate of 1.0 mL/min with UV-detection at 215 nm. The method separated the four components simultaneously in less than 10 min. The validation of the method was performed with respect to specificity, linearity, accuracy, and precision. The calibration curves were linear in the range of 35.1-81.9 μ/mL for triacetin, 431.1-1005.9 μ/mL for acetic ether, 167.0-389.7 μ/mL for butyl acetate and 151.0-352.3 μ/mL for amorolfine. The mean 100% spiked recovery for triacetin, acetic ether, butyl acetate and amorolfine is 99.43 ± 0.42, 101.5 ± 1.09, 101.4 ± 1.02 and 100.8 ± 0.69, respectively. The intra-day and inter-day relative standard deviation values were <2.0%. The limits of detection of these compounds ranged from 0.08 to 5.88 ng. The utility of the procedure was verified by its application to the commercial liniment.

  8. validated microbiological and HPLC methods for the determination of moxifloxacin in pharmaceutical preparations and human plasma.

    PubMed

    Abdelaziz, Ahmed A; Elbanna, Tarek E; Gamaleldeen, Noha M

    2012-10-01

    The article presents a comparison between microbiological and high performance liquid chromatographic (HPLC) assays for quantification of moxifloxacin in tablets, ophthalmic solutions and human plasma. The microbiological method employed a cylinder-plate agar diffusion assay using a strain of Esherichia coli ATCC 25922 as the test organism and phosphate buffer (pH8) as the diluent. The calibration curves were linear (R(2) > 0.98) over a concentration range of 0.125 to 16 µgml(-1). The within day and between days precisions were ≤ 4.47% and ≤ 6.39% respectively. Recovery values were between 89.4 and 110.2%. The HPLC assay used Hypersil(®) BDS C18 reversed phase column (250×4.6 mm, 5µm) with a mobile phase comprising 20 mM ammonium dihydrogen orthophosphate (pH3) and acetonitrile (75:25) and flowing at 1.5 ml/min. The detection was at 295nm. The calibration curves were linear (R(2) > 0.999) over the range of 0.125 to 16 µg ml(-1). The within day and between days precisions were ≤ 4.07% and ≤ 5.09% respectively. Recovery values were between 97.7 and 107.6%. Similar potencies were obtained after the analysis of moxifloxacin tablets and ophthalmic solutions by both methods. Also pharmacokinetic parameters were calculated after the analysis of plasma samples of six male healthhy volunteers by both validated methods.

  9. A UPLC-MS/MS method for simultaneous determination of five flavonoids from Stellera chamaejasme L. in rat plasma and its application to a pharmacokinetic study.

    PubMed

    Li, Yun-Qing; Li, Cheng-Jian; Lv, Lei; Cao, Qing-Qing; Qian, Xian; Li, Si Wei; Wang, Hui; Zhao, Liang

    2018-06-01

    Stellera chamaejasme L. has been used as a traditional Chinese medicine for the treatment of scabies, tinea, stubborn skin ulcers, chronic tracheitis, cancer and tuberculosis. A sensitive and selective ultra-high liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of five flavonoids (stelleranol, chamaechromone, neochamaejasmin A, chamaejasmine and isochamaejasmin) of S. chamaejasme L. in rat plasma. Chromatographic separation was accomplished on an Agilent Poroshell 120 EC-C 18 column (2.1 × 100 mm, 2.7 μm) with gradient elution at a flow rate of 0.4 mL/min and the total analysis time was 7 min. The analytes were detected using multiple reaction monitoring in positive ionization mode. The samples were prepared by liquid-liquid extraction with ethyl acetate. The UPLC-MS/MS method was validated for specificity, linearity, sensitivity, accuracy and precision, recovery, matrix effect and stability. The validated method exhibited good linearity (r ≥ 0.9956), and the lower limits of quantification ranged from 0.51 to 0.64 ng/mL for five flavonoids. The intra- and inter-day precision were both <10.2%, and the accuracy ranged from -11.79 to 9.21%. This method was successfully applied to a pharmacokinetic study of five flavonoids in rats after oral administration of ethyl acetate extract of S. chamaejasme L. Copyright © 2018 John Wiley & Sons, Ltd.

  10. Multiple-channel ultra-violet absorbance detector for two-dimensional chromatographic separations.

    PubMed

    Lynch, Kyle B; Yang, Yu; Ren, Jiangtao; Liu, Shaorong

    2018-05-01

    In recent years, much research has gone into developing online comprehensive two-dimensional liquid chromatographic systems allowing for high peak capacities in comparable separation times to that of one-dimensional liquid chromatographic systems. However, the speed requirements in the second dimension (2nd-D) still remain one challenge for complex biological samples due to the current configuration of two column/two detector systems. Utilization of multiple 2nd-D columns can mitigate this challenge. To adapt this approach, we need a multiple channel detector. Here we develop a versatile multichannel ultraviolet (UV) light absorbance detector that is capable of simultaneously monitoring separations in 12 columns. The detector consists of a deuterium lighthouse, a flow cell assembly (a 13-channel flow cell fitted with a 13-photodiode-detection system), and a data acquisition and monitoring terminal. Through the use of a custom high optical quality furcated fiber to improve light transmission, precise machining of a flow cell to reduce background stray light through precision alignment, and sensitive electronic circuitry to reduce electronic noise through an active low pass filter, the background noise level is measured in the tens of µAU. We obtain a linear dynamic range of close to three orders of magnitude. Compared to a commercialized multichannel UV light absorbance detector like the Waters 2488 UV/Vis, our device provides an increase in channel detection while residing within the same noise region and linear range. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. A Fast and Validated Reversed-Phase HPLC Method for Simultaneous Determination of Simvastatin, Atorvastatin, Telmisartan and Irbesartan in Bulk Drugs and Tablet Formulations

    PubMed Central

    Alhazmi, Hassan A.; Alnami, Ahmed M.; Arishi, Mohammed A. A.; Alameer, Raad K.; Al Bratty, Mohammed; Rehman, Zia ur; Javed, Sadique A.; Arbab, Ismail A.

    2017-01-01

    The aim of this study was to develop and validate a fast and simple reversed-phase HPLC method for simultaneous determination of four cardiovascular agents—atorvastatin, simvastatin, telmisartan and irbesartan in bulk drugs and tablet oral dosage forms. The chromatographic separation was accomplished by using Symmetry C18 column (75 mm × 4.6 mm; 3.5 μ) with a mobile phase consisting of ammonium acetate buffer (10 mM; pH 4.0) and acetonitrile in a ratio 40:60 v/v. Flow rate was maintained at 1 mL/min up to 3.5 min, and then suddenly changed to 2 mL/min till the end of the run (7.5 min). The data was acquired using ultraviolet detector monitored at 220 nm. The method was validated for linearity, precision, accuracy and specificity. The developed method has shown excellent linearity (R2 > 0.999) over the concentration range of 1–16 µg/mL. The limits of detection (LODs) and limits of quantification (LOQs) were in the range of 0.189–0.190 and 0.603–0.630 µg/mL, respectively. Inter-day and intra-day accuracy and precision data were recorded in the acceptable limits. The new method has successfully been applied for quantification of all four drugs in their tablet dosage forms with percent recovery within 100 ± 2%. PMID:29257120

  12. Spectrofluorimetric determination of some water-soluble vitamins.

    PubMed

    Mohamed, Abdel-Maaboud I; Mohamed, Horria A; Abdel-Latif, Niveen M; Mohamed, Marwa R

    2011-01-01

    Two simple and sensitive spectrofluorimetric methods were developed for determination of three water-soluble vitamins (B1, B2, and B6) in mixtures in the presence of cyanocobalamin. The first one was for thiamine determination, which depends on the oxidation of thiamine HCl to thiochrome by iodine in an alkaline medium. The method was applied accurately to determine thiamine in binary, ternary, and quaternary mixtures with pyridoxine HCl, riboflavin, and cyanocobalamin without interference. In the second method, riboflavin and pyridoxine HCl were determined fluorimetrically in acetate buffer, pH 6. The three water-soluble vitamins (B1, B2, and B6) were determined spectrofluorimetrically in binary, ternary, and quaternary mixtures in the presence of cyanocobalamin. All variables were studied in order to optimize the reaction conditions. Linear relationship was obeyed for all studied vitamins by the proposed methods at their corresponding lambda(exc) or lambda(em). The linear calibration curves were obtained from 10 to 500 ng/mL; the correlation ranged from 0.9991 to 0.9999. The suggested procedures were applied to the analysis of the investigated vitamins in their laboratory-prepared mixtures and pharmaceutical dosage forms from different manufacturers. The RSD range was 0.46-1.02%, which indicates good precision. No interference was observed from common pharmaceutical additives. Good recoveries (97.6 +/- 0.7-101.2 +/- 0.8%) were obtained. Statistical comparison of the results with reported methods shows excellent agreement and indicates no significant difference in accuracy and precision.

  13. Quantitative determination of insulin entrapment efficiency in triblock copolymeric nanoparticles by high-performance liquid chromatography.

    PubMed

    Xu, Xiongliang; Fu, Yao; Hu, Haiyan; Duan, Yourong; Zhang, Zhirong

    2006-04-11

    A rapid and effective isocratic chromatographic procedure was described in this paper for the determination of insulin entrapment efficiency (EE) in triblock copolymeric nanoparticles using reversed-phase high-performance liquid chromatography (RP-HPLC) with an ultraviolet/visible detector at low flow rate. The method has been developed on a Shimadzu Shim-pack VP-ODS column (150 mm x 4.6 mm, 5 microm, Chiyoda-Ku, Tokyo, Japan) using a mixture of 0.2 M sodium sulfate anhydrous solution adjusted to pH 2.3 with phosphoric acid and acetonitrile (73:27, v/v) as mobile phase at the flow rate of 0.8 ml min(-1) and a 214 nm detection. The method was validated in terms of selectivity, linearity, precision, accuracy, solution stability, limit of detection (LOD) and limit of quantification (LOQ). The calibration curve was linear in the concentration range of 2.0-500.0 microg ml(-1), and the limits of detection and quantitation were 8 and 20 ng, respectively. The mean recovery of insulin from spiked samples, in a concentration range of 8-100 microg ml(-1), was 98.96% (R.S.D.= 2.51%, n = 9). The intra- and inter-assay coefficients of variation were less than 2.24%. The proposed method has the advantages of simple pretreatment, rapid isolation, high specificity and precision, which can be used for direct analysis of insulin in commercially available raw materials, formulations of nanoparticles, and drug release as well as stability studies.

  14. Concurrent determination of olanzapine, risperidone and 9-hydroxyrisperidone in human plasma by ultra performance liquid chromatography with diode array detection method: application to pharmacokinetic study.

    PubMed

    Siva Selva Kumar, M; Ramanathan, M

    2016-02-01

    A simple and sensitive ultra-performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of olanzapine (OLZ), risperidone (RIS) and 9-hydroxyrisperidone (9-OHRIS) in human plasma in vitro. The sample preparation was performed by simple liquid-liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP18 column maintained at 40°C. Quantification was performed on a photodiode array detector set at 277 nm and clozapine was used as internal standard (IS). OLZ, RIS, 9-OHRIS and IS retention times were found to be 0.9, 1.4, .1.8 and 3.1 min, respectively, and the total run time was 4 min. The method was validated for selectivity, specificity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 1-100 ng/mL for OLZ, RIS and 9-OHRIS. Intra- and inter-day precisions for OLZ, RIS and 9-OHRIS were found to be good with the coefficient of variation <6.96%, and the accuracy ranging from 97.55 to 105.41%, in human plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of RIS and 9-OHRIS in human plasma. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Fast and parallel determination of PCB 77 and PCB 180 in plasma using ultra performance liquid chromatography with diode array detection: A pharmacokinetic study in Swiss albino mouse.

    PubMed

    Ramanujam, N; Sivaselvakumar, M; Ramalingam, S

    2017-11-01

    A simple, sensitive and reproducible ultra-performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of polychlorinated biphenyl (PCB) 77 and PCB 180 in mouse plasma. The sample preparation was performed by simple liquid-liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP 18 column maintained at 35°C. Quantification was performed on a photodiode array detector set at 215 nm and PCB 101 was used as internal standard (IS). PCB 77, PCB 180, and IS retention times were 2.6, 4.7 and 2.8 min, respectively, and the total run time was 6 min. The method was validated for specificity, selectivity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 10-3000 ng/mL for PCB 77 and PCB 180. Intra- and inter-day precisions for PCBs 77 and 180 were found to be good with CV <4.64%, and the accuracy ranged from 98.90 to 102.33% in mouse plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of PCBs 77 and 180 in mouse plasma. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Construction accident narrative classification: An evaluation of text mining techniques.

    PubMed

    Goh, Yang Miang; Ubeynarayana, C U

    2017-11-01

    Learning from past accidents is fundamental to accident prevention. Thus, accident and near miss reporting are encouraged by organizations and regulators. However, for organizations managing large safety databases, the time taken to accurately classify accident and near miss narratives will be very significant. This study aims to evaluate the utility of various text mining classification techniques in classifying 1000 publicly available construction accident narratives obtained from the US OSHA website. The study evaluated six machine learning algorithms, including support vector machine (SVM), linear regression (LR), random forest (RF), k-nearest neighbor (KNN), decision tree (DT) and Naive Bayes (NB), and found that SVM produced the best performance in classifying the test set of 251 cases. Further experimentation with tokenization of the processed text and non-linear SVM were also conducted. In addition, a grid search was conducted on the hyperparameters of the SVM models. It was found that the best performing classifiers were linear SVM with unigram tokenization and radial basis function (RBF) SVM with uni-gram tokenization. In view of its relative simplicity, the linear SVM is recommended. Across the 11 labels of accident causes or types, the precision of the linear SVM ranged from 0.5 to 1, recall ranged from 0.36 to 0.9 and F1 score was between 0.45 and 0.92. The reasons for misclassification were discussed and suggestions on ways to improve the performance were provided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Stability indicating RP-HPLC method development and validation for the simultaneous determination of aminexil and minoxidil in pharmaceutical dosage form.

    PubMed

    Siddiraju, S; Sahithi, M

    2015-03-01

    The objective of the present work is to develop stability indicating high-performance liquid chromatographic method for the simultaneous determination of aminexil and minoxidil in pharmaceutical dosage form. The chromatographic separation was achieved with BDS Hypersil C18 column (250 mm×4.6 mm×5 μ) as stationary phase and phosphate buffer and acetonitrile (78:22) as mobile phase. The method was employed by using a flow rate of 1.1 mL/min kept at 30°C. The detection wavelength was kept at 238 nm by using photo-diode array detector. The retention times of the aminexil and minoxidil were found to be 2.3 min and 3.9 min, respectively. The method developed was validated in accordance with ICH guidelines with respect to the stability indicating capacity of the method including system suitability, accuracy, precision, linearity, range, limit of detection, limit of quantification and robustness. The linearity responses of aminexil and minoxidil were found to be in the concentration ranges of 18.75-112.5 μg/mL and 25-150 μg/mL, respectively. The LOD and LOQ values for aminexil were found to be 0.31 and 0.92 μg/mL and minoxidil were found to be 0.03 and 0.10 μg/mL respectively. The percentage recoveries for both the drugs were found in the range of 98-101%. This method is accurate, precise and sensitive; hence, it can be employed for routine quality control of aminexil and minoxidil in pharmaceutical industries and drug testing laboratories. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Capabilities and limitations of dispersive liquid-liquid microextraction with solidification of floating organic drop for the extraction of organic pollutants from water samples.

    PubMed

    Vera-Avila, Luz E; Rojo-Portillo, Tania; Covarrubias-Herrera, Rosario; Peña-Alvarez, Araceli

    2013-12-17

    Dispersive liquid-liquid microextraction with solidification of floating organic drop (DLLME-SFO) is one of the most interesting sample preparation techniques developed in recent years. Although several applications have been reported, the potentiality and limitations of this simple and rapid extraction technique have not been made sufficiently explicit. In this work, the extraction efficiency of DLLME-SFO for pollutants from different chemical families was determined. Studied compounds include: 10 polycyclic aromatic hydrocarbons, 5 pesticides (chlorophenoxy herbicides and DDT), 8 phenols and 6 sulfonamides, thus, covering a large range of polarity and hydrophobicity (LogKow 0-7, overall). After optimization of extraction conditions using 1-dodecanol as extractant, the procedure was applied for extraction of each family from 10-mL spiked water samples, only adjusting sample pH as required. Absolute recoveries for pollutants with LogKow 3-7 were >70% and recovery values within this group (18 compounds) were independent of structure or hydrophobicity; the precision of recovery was very acceptable (RSD<12%) and linear behavior was observed in the studied concentration range (r(2)>0.995). Extraction recoveries for pollutants with LogKow 1.46-2.8 were in the range 13-62%, directly depending on individual LogKow values; however, good linearity (r(2)>0.993) and precision (RSD<6.5%) were also demonstrated for these polar solutes, despite recovery level. DLLME-SFO with 1-dodecanol completely failed for extraction of compounds with LogKow≤1 (sulfa drugs), other more polar extraction solvents (ionic liquids) should be explored for highly hydrophilic pollutants. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Ultrasensitive quantification of the CYP2E1 probe chlorzoxazone and its main metabolite 6-hydroxychlorzoxazone in human plasma using ultra performance liquid chromatography coupled to tandem mass spectrometry after chlorzoxazone microdosing.

    PubMed

    Witt, Lukas; Suzuki, Yosuke; Hohmann, Nicolas; Mikus, Gerd; Haefeli, Walter E; Burhenne, Jürgen

    2016-08-01

    Chlorzoxazone is a probe drug to assess cytochrome P450 (CYP) 2E1 activity (phenotyping). If the pharmacokinetics of the probe drug is linear, pharmacologically ineffective doses are sufficient for the purpose of phenotyping and adverse effects can thus be avoided. For this reason, we developed and validated an assay for the ultrasensitive quantification of chlorzoxazone and 6-hydroxychlorzoxazone in human plasma. Plasma (0.5mL) and liquid/liquid partitioning were used for sample preparation. Extraction recoveries ranged between 76 and 93% for both analytes. Extracts were separated within 3min on a Waters BEH C18 Shield 1.7μm UPLC column with a fast gradient consisting of aqueous formic acid and acetonitrile. Quantification was achieved using internal standards labeled with deuterium or (13)C and tandem mass spectrometry in the multiple reaction monitoring mode using negative electrospray ionization, which yielded lower limits of quantification of 2.5pgmL(-1), while maintaining a precision always below 15%. The calibrated concentration ranges were linear for both analytes (2.5-1000pgmL(-1)) with correlation coefficients of >0.99. Within-batch and batch-to-batch precision in the calibrated ranges for both analytes were <15% and <11% and plasma matrix effects always were below 50%. The assay was successfully applied to assess the pharmacokinetics of chlorzoxazone in two human volunteers after administration of single oral doses (2.5-5000μg). This ultrasensitive assay allowed the determination of chlorzoxazone pharmacokinetics for 8h after microdosing of 25μg chlorzoxazone. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. A methodology based on reduced complexity algorithm for system applications using microprocessors

    NASA Technical Reports Server (NTRS)

    Yan, T. Y.; Yao, K.

    1988-01-01

    The paper considers a methodology on the analysis and design of a minimum mean-square error criterion linear system incorporating a tapped delay line (TDL) where all the full-precision multiplications in the TDL are constrained to be powers of two. A linear equalizer based on the dispersive and additive noise channel is presented. This microprocessor implementation with optimized power of two TDL coefficients achieves a system performance comparable to the optimum linear equalization with full-precision multiplications for an input data rate of 300 baud.

  1. Development of an isocratic HPLC method for catechin quantification and its application to formulation studies.

    PubMed

    Li, Danhui; Martini, Nataly; Wu, Zimei; Wen, Jingyuan

    2012-10-01

    The aim of this study was to develop a simple, rapid and accurate isocratic HPLC analytical method to qualify and quantify five catechin derivatives, namely (+)-catechin (C), (-)-epigallocatechin (EGC), (-)-epicatechin gallate (ECG), (-)-epicatechin (EC) and (-)-epigallocatechin gallate (EGCG). To validate the analytical method, linearity, repeatability, intermediate precision, sensitivity, selectivity and recovery were investigated. The five catechin derivatives were completely separated by HPLC using a mobile phase containing 0.1% TFA in Milli-Q water (pH 2.0) mixed with methanol at the volume ratio of 75:25 at a flow rate of 0.8 ml/min. The method was shown to be linear (r²>0.99), repeatable with instrumental precision<2.0 and intra-assay precision<2.5 (%CV, percent coefficient of variation), precise with intra-day variation<1 and inter-day variation<2.5 (%CV, percent coefficient of variation) and sensitive (LOD<1 μg/mL and LOQ<3 μg/mL) over the calibration range for all five derivatives. Derivatives could be fully recovered in the presence of niosomal formulation (recovery rates>91%). Selectivity of the method was proven by the forced degradation studies, which showed that under acidic, basic, oxidation temperature and photolysis stresses, the parent drug can be separated from the degradation products by means of this analytical method. The described method was successfully applied in the in vitro release studies of catechin-loaded niosomes to manifest its utility in formulation characterization. Obtained results indicated that the drug release from niosomal formulations was a biphasic process and a diffusion mechanism regulated the permeation of catechin niosomes. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Adaptive nonsingular terminal sliding mode controller for micro/nanopositioning systems driven by linear piezoelectric ceramic motors.

    PubMed

    Safa, Alireza; Abdolmalaki, Reza Yazdanpanah; Shafiee, Saeed; Sadeghi, Behzad

    2018-06-01

    In the field of nanotechnology, there is a growing demand to provide precision control and manipulation of devices with the ability to interact with complex and unstructured environments at micro/nano-scale. As a result, ultrahigh-precision positioning stages have been turned into a key requirement of nanotechnology. In this paper, linear piezoelectric ceramic motors (LPCMs) are adopted to drive micro/nanopositioning stages since they have the ability to achieve high precision in addition to being versatile to be implemented over a wide range of applications. In the establishment of a control scheme for such manipulation systems, the presence of friction, parameter uncertainties, and external disturbances prevent the systems from providing the desired positioning accuracy. The work in this paper focuses on the development of a control framework that addresses these issues as it uses the nonsingular terminal sliding mode technique for the precise position tracking problem of an LPCM-driven positioning stage with friction, uncertain parameters, and external disturbances. The developed control algorithm exhibits the following two attractive features. First, upper bounds of system uncertainties/perturbations are adaptively estimated in the proposed controller; thus, prior knowledge about uncertainty/disturbance bounds is not necessary. Second, the discontinuous signum function is transferred to the time derivative of the control input and the continuous control signal is obtained after integration; consequently, the chattering phenomenon, which presents a major handicap to the implementation of conventional sliding mode control in real applications, is alleviated without deteriorating the robustness of the system. The stability of the controlled system is analyzed, and the convergence of the position tracking error to zero is analytically proven. The proposed control strategy is experimentally validated and compared to the existing control approaches. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  3. Magnetic N-doped carbon nanotubes: A versatile and efficient material for the determination of polycyclic aromatic hydrocarbons in environmental water samples.

    PubMed

    Menezes, Helvécio Costa; de Barcelos, Stella Maris Resende; Macedo, Damiana Freire Dias; Purceno, Aluir Dias; Machado, Bruno Fernades; Teixeira, Ana Paula Carvalho; Lago, Rochel Monteiro; Serp, Philippe; Cardeal, Zenilda Lourdes

    2015-05-11

    This paper describes a new, efficient and versatile method for the sampling and preconcentration of PAH in environmental water matrices using special hybrid magnetic carbon nanotubes. These N-doped amphiphilic CNT can be easily dispersed in any aqueous matrix due to the N containing hydrophilic part and at the same time show high efficiency for the adsorption of different PAH contaminants due to the very hydrophobic surface. After adsorption, the CNT can be easily removed from the medium by a simple magnetic separation. GC/MS analyses showed that the CNT method is more efficient than the use of polydimethylsiloxane (PDMS) with much lower solvent consumption, technical simplicity and time, showing good linearity (range 0.18-80.00 μg L(-1)) and determination coefficient (R(2) > 0.9810). The limit of detection ranged from 0.05 to 0.42 μg L(-1) with limit of quantification from 0.18 to 1.40 μg L(-1). Recovery (n=9) ranged from 80.50 ± 10 to 105.40 ± 12%. Intraday precision (RSD, n=9) ranged from 1.91 to 9.01%, whereas inter day precision (RSD, n=9) ranged from 7.02 to 17.94%. The method was applied to the analyses of PAH in four lake water samples collected in Belo Horizonte City, Brazil. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Development and validation of a high performance liquid chromatographic method for the determination of oxcarbazepine and its main metabolites in human plasma and cerebrospinal fluid and its application to pharmacokinetic study.

    PubMed

    Kimiskidis, Vasilios; Spanakis, Marios; Niopas, Ioannis; Kazis, Dimitrios; Gabrieli, Chrysi; Kanaze, Feras Imad; Divanoglou, Daniil

    2007-01-17

    An isocratic reversed-phase HPLC-UV procedure for the determination of oxcarbazepine and its main metabolites 10-hydroxy-10,11-dihydrocarbamazepine and 10,11-dihydroxy-trans-10,11-dihydrocarbamazepine in human plasma and cerebrospinal fluid has been developed and validated. After addition of bromazepam as internal standard, the analytes were isolated from plasma and cerebrospinal fluid by liquid-liquid extraction. Separation was achieved on a X-TERRA C18 column using a mobile phase composed of 20 mM KH(2)PO(4), acetonitrile, and n-octylamine (76:24:0.05, v/v/v) at 40 degrees C and detected at 237 nm. The described assay was validated in terms of linearity, accuracy, precision, recovery and lower limit of quantification according to the FDA validation guidelines. Calibration curves were linear with a coefficient of variation (r) greater than 0.998. Accuracy ranged from 92.3% to 106.0% and precision was between 2.3% and 8.2%. The method has been applied to plasma and cerebrospinal fluid samples obtained from patients treated with oxcarbazepine, both in monotherapy and adjunctive therapy.

  5. Conical scan impact study. Volume 1: General central data processing facility. [multispectral band scanner design alternatives for earth resources data

    NASA Technical Reports Server (NTRS)

    Ebert, D. H.; Eppes, T. A.; Thomas, D. J.

    1973-01-01

    The impact of a conical scan versus a linear scan multispectral scanner (MSS) instrument was studied in terms of: (1) design modifications required in framing and continuous image recording devices; and (2) changes in configurations of an all-digital precision image processor. A baseline system was defined to provide the framework for comparison, and included pertinent spacecraft parameters, a conical MSS, a linear MSS, an image recording system, and an all-digital precision processor. Lateral offset pointing of the sensors over a range of plus or minus 20 deg was considered. The study addressed the conical scan impact on geometric, radiometric, and aperture correction of MSS data in terms of hardware and software considerations, system complexity, quality of corrections, throughput, and cost of implementation. It was concluded that: (1) if the MSS data are to be only film recorded, then there is only a nomial concial scan impact on the ground data processing system; and (2) if digital data are to be provided to users on computer compatible tapes in rectilinear format, then there is a significant conical scan impact on the ground data processing system.

  6. Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part I: Liquid chromatography-tandem mass spectrometry analysis.

    PubMed

    Aszyk, Justyna; Kubica, Paweł; Kot-Wasik, Agata; Namieśnik, Jacek; Wasik, Andrzej

    2017-10-13

    Liquid chromatography-tandem mass spectrometry with electrospray ionization (HPLC-ESI-MS/MS) methods were developed for the simultaneous determination of 42 flavouring compounds and nicotine in liquids for e-cigarettes. The chromatographic separation was performed using an Ace ® Ultracore™ SuperC18™ (100×2.1mm, 2.5μm) column in both acidic and alkaline pH conditions to separate all the compounds. A simple "dilute & shoot" approach was used for the sample preparation. The method validation was performed by evaluating key analytical parameters such as linearity, accuracy, selectivity, precision, limit of detection (LOD) and limit of quantification (LOQ). The calibration curves showed good linearity within the specific ranges for the investigated compounds with correlation coefficients greater than 0.990 in each case. The recovery for all the investigated compounds varied from 89% to 110%. The intra- and inter-day precision were within the acceptable limits (±15%) at all tested concentrations. The applicability of the methods was examined by analysing 25 liquid samples from e-cigarettes commercially available on the Polish market. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A comparative study of first-derivative spectrophotometry and column high-performance liquid chromatography applied to the determination of repaglinide in tablets and for dissolution testing.

    PubMed

    AlKhalidi, Bashar A; Shtaiwi, Majed; AlKhatib, Hatim S; Mohammad, Mohammad; Bustanji, Yasser

    2008-01-01

    A fast and reliable method for the determination of repaglinide is highly desirable to support formulation screening and quality control. A first-derivative UV spectroscopic method was developed for the determination of repaglinide in tablet dosage form and for dissolution testing. First-derivative UV absorbance was measured at 253 nm. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) in comparison to the U.S. Pharmacopeia (USP) column high-performance liquid chromatographic (HPLC) method. The first-derivative UV spectrophotometric method showed excellent linearity [correlation coefficient (r) = 0.9999] in the concentration range of 1-35 microg/mL and precision (relative standard deviation < 1.5%). The LOD and LOQ were 0.23 and 0.72 microg/mL, respectively, and good recoveries were achieved (98-101.8%). Statistical comparison of results of the first-derivative UV spectrophotometric and the USP HPLC methods using the t-test showed that there was no significant difference between the 2 methods. Additionally, the method was successfully used for the dissolution test of repaglinide and was found to be reliable, simple, fast, and inexpensive.

  8. Electron kinetic effects on interferometry, polarimetry and Thomson scattering measurements in burning plasmas (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mirnov, V. V.; Hartog, D. J. Den; Duff, J.

    2014-11-15

    At anticipated high electron temperatures in ITER, the effects of electron thermal motion on Thomson scattering (TS), toroidal interferometer/polarimeter (TIP), and poloidal polarimeter (PoPola) diagnostics will be significant and must be accurately treated. The precision of the previous lowest order linear in τ = T{sub e}/m{sub e}c{sup 2} model may be insufficient; we present a more precise model with τ{sup 2}-order corrections to satisfy the high accuracy required for ITER TIP and PoPola diagnostics. The linear model is extended from Maxwellian to a more general class of anisotropic electron distributions that allows us to take into account distortions caused bymore » equilibrium current, ECRH, and RF current drive effects. The classical problem of the degree of polarization of incoherent Thomson scattered radiation is solved analytically exactly without any approximations for the full range of incident polarizations, scattering angles, and electron thermal motion from non-relativistic to ultra-relativistic. The results are discussed in the context of the possible use of the polarization properties of Thomson scattered light as a method of T{sub e} measurement relevant to ITER operational scenarios.« less

  9. RP-HPLC Method Development and Validation for Determination of Eptifibatide Acetate in Bulk Drug Substance and Pharmaceutical Dosage Forms

    PubMed Central

    Bavand Savadkouhi, Maryam; Vahidi, Hossein; Ayatollahi, Abdul Majid; Hooshfar, Shirin; Kobarfard, Farzad

    2017-01-01

    A new, rapid, economical and isocratic reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of eptifibatide acetate, a small synthetic antiplatelet peptide, in bulk drug substance and pharmaceutical dosage forms. The developed method was validated as per of ICH guidelines. The chromatographic separation was achieved isocratically on C18 column (150 x 4.60 mm i.d., 5 µM particle size) at ambient temperature using acetonitrile (ACN), water and trifluoroacetic acid (TFA) as mobile phase at flow rate of 1 mL/min and UV detection at 275 nm. Eptifibatide acetate exhibited linearity over the concentration range of 0.15-2 mg/mL (r2=0.997) with limit of detection of 0.15 mg/mL The accuracy of the method was 96.4-103.8%. The intra-day and inter-day precision were between 0.052% and 0.598%, respectively. The present successfully validated method with excellent selectivity, linearity, sensitivity, precision and accuracy was applicable for the assay of eptifibatide acetate in bulk drug substance and pharmaceutical dosage forms. PMID:28979304

  10. Shot noise limited characterization of ultraweak femtosecond pulse trains.

    PubMed

    Schwartz, Osip; Raz, Oren; Katz, Ori; Dudovich, Nirit; Oron, Dan

    2011-01-17

    Ultrafast science is inherently, due to the lack of fast enough detectors and electronics, based on nonlinear interactions. Typically, however, nonlinear measurements require significant powers and often operate in a limited spectral range. Here we overcome the difficulties of ultraweak ultrafast measurements by precision time-domain localization of spectral components. We utilize this for linear self-referenced characterization of pulse trains having ∼ 1 photon per pulse, a regime in which nonlinear techniques are impractical, at a temporal resolution of ∼ 10 fs. This technique does not only set a new scale of sensitivity in ultrashort pulse characterization, but is also applicable in any spectral range from the near-infrared to the deep UV.

  11. Validation of a Thin-Layer Chromatography for the Determination of Hydrocortisone Acetate and Lidocaine in a Pharmaceutical Preparation

    PubMed Central

    Dołowy, Małgorzata; Kulpińska-Kucia, Katarzyna; Pyka, Alina

    2014-01-01

    A new specific, precise, accurate, and robust TLC-densitometry has been developed for the simultaneous determination of hydrocortisone acetate and lidocaine hydrochloride in combined pharmaceutical formulation. The chromatographic analysis was carried out using a mobile phase consisting of chloroform + acetone + ammonia (25%) in volume composition 8 : 2 : 0.1 and silica gel 60F254 plates. Densitometric detection was performed in UV at wavelengths 200 nm and 250 nm, respectively, for lidocaine hydrochloride and hydrocortisone acetate. The validation of the proposed method was performed in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and robustness. The applied TLC procedure is linear in hydrocortisone acetate concentration range of 3.75 ÷ 12.50 μg·spot−1, and from 1.00 ÷ 2.50 μg·spot−1 for lidocaine hydrochloride. The developed method was found to be accurate (the value of the coefficient of variation CV [%] is less than 3%), precise (CV [%] is less than 2%), specific, and robust. LOQ of hydrocortisone acetate is 0.198 μg·spot−1 and LOD is 0.066 μg·spot−1. LOQ and LOD values for lidocaine hydrochloride are 0.270 and 0.090 μg·spot−1, respectively. The assay value of both bioactive substances is consistent with the limits recommended by Pharmacopoeia. PMID:24526880

  12. Validation of a thin-layer chromatography for the determination of hydrocortisone acetate and lidocaine in a pharmaceutical preparation.

    PubMed

    Dołowy, Małgorzata; Kulpińska-Kucia, Katarzyna; Pyka, Alina

    2014-01-01

    A new specific, precise, accurate, and robust TLC-densitometry has been developed for the simultaneous determination of hydrocortisone acetate and lidocaine hydrochloride in combined pharmaceutical formulation. The chromatographic analysis was carried out using a mobile phase consisting of chloroform+acetone+ammonia (25%) in volume composition 8:2:0.1 and silica gel 60F254 plates. Densitometric detection was performed in UV at wavelengths 200 nm and 250 nm, respectively, for lidocaine hydrochloride and hydrocortisone acetate. The validation of the proposed method was performed in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and robustness. The applied TLC procedure is linear in hydrocortisone acetate concentration range of 3.75÷12.50  μg·spot(-1), and from 1.00÷2.50  μg·spot(-1) for lidocaine hydrochloride. The developed method was found to be accurate (the value of the coefficient of variation CV [%] is less than 3%), precise (CV [%] is less than 2%), specific, and robust. LOQ of hydrocortisone acetate is 0.198  μg·spot(-1) and LOD is 0.066  μg·spot(-1). LOQ and LOD values for lidocaine hydrochloride are 0.270 and 0.090  μg·spot(-1), respectively. The assay value of both bioactive substances is consistent with the limits recommended by Pharmacopoeia.

  13. Purity assessment of recombinant human granulocyte colony-stimulating factor in finished drug product by capillary zone electrophoresis.

    PubMed

    Benković, Goran; Skrlin, Ana; Madić, Tomislav; Debeljak, Zeljko; Medić-Šarić, Marica

    2014-09-01

    Current methods for determination of impurities with different charge-to-volume ratio are limited especially in terms of sensitivity and precision. The main goal of this research was to establish a quantitative method for determination of impurities with charges differing from that of recombinant human granulocyte colony-stimulating factor (rhG-CSF, filgrastim) with superior precision and sensitivity compared to existing methods. A CZE method has been developed, optimized, and validated for a purity assessment of filgrastim in liquid pharmaceutical formulations. Optimal separation of filgrastim from the related impurities with different charges was achieved on a 50 μm id fused-silica capillary of a total length of 80.5 cm. A BGE that contains 100 mM phosphoric acid adjusted to pH 7.0 with triethanolamine was used. The applied voltage was 20 kV while the temperature was maintained at 25°C. UV detection was set to 200 nm. Method was validated in terms of selectivity/specificity, linearity, precision, LOD, LOQ, stability, and robustness. Linearity was observed in the concentration range of 6-600 μg/mL and the LOQ was determined to be 0.3% relative to the concentration of filgrastim of 0.6 mg/mL. Other validation parameters were also found to be acceptable; thus the method was successfully applied for a quantitative purity assessment of filgrastim in a finished drug product. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Proton beam spatial distribution and Bragg peak imaging by photoluminescence of color centers in lithium fluoride crystals at the TOP-IMPLART linear accelerator

    NASA Astrophysics Data System (ADS)

    Piccinini, M.; Ronsivalle, C.; Ampollini, A.; Bazzano, G.; Picardi, L.; Nenzi, P.; Trinca, E.; Vadrucci, M.; Bonfigli, F.; Nichelatti, E.; Vincenti, M. A.; Montereali, R. M.

    2017-11-01

    Solid-state radiation detectors based on the photoluminescence of stable point defects in lithium fluoride crystals have been used for advanced diagnostics during the commissioning of the segment up to 27 MeV of the TOP-IMPLART proton linear accelerator for proton therapy applications, under development at ENEA C.R. Frascati, Italy. The LiF detectors high intrinsic spatial resolution and wide dynamic range allow obtaining two-dimensional images of the beam transverse intensity distribution and also identifying the Bragg peak position with micrometric precision by using a conventional optical fluorescence microscope. Results of the proton beam characterization, among which, the estimation of beam energy components and dynamics, are reported and discussed for different operating conditions of the accelerator.

  15. An automated real-time free phenytoin assay to replace the obsolete Abbott TDx method.

    PubMed

    Williams, Christopher; Jones, Richard; Akl, Pascale; Blick, Kenneth

    2014-01-01

    Phenytoin is a commonly used anticonvulsant that is highly protein bound with a narrow therapeutic range. The unbound fraction, free phenytoin (FP), is responsible for pharmacologic effects; therefore, it is essential to measure both FP and total serum phenytoin levels. Historically, the Abbott TDx method has been widely used for the measurement of FP and was the method used in our laboratory. However, the FP TDx assay was recently discontinued by the manufacturer, so we had to develop an alternative methodology. We evaluated the Beckman-Coulter DxC800 based FP method for linearity, analytical sensitivity, and precision. The analytical measurement range of the method was 0.41 to 5.30 microg/mL. Within-run and between-run precision studies yielded CVs of 3.8% and 5.5%, respectively. The method compared favorably with the TDx method, yielding the following regression equation: DxC800 = 0.9**TDx + 0.10; r2 = 0.97 (n = 97). The new FP assay appears to be an acceptable alternative to the TDx method.

  16. Airborne Measurements of CO2 Column Absorption and Range Using a Pulsed Direct-Detection Integrated Path Differential Absorption Lidar

    NASA Technical Reports Server (NTRS)

    Abshire, James B.; Riris, Haris; Weaver, Clark J.; Mao, Jianping; Allan, Graham R.; Hasselbrack, William E.; Browell, Edward V.

    2013-01-01

    We report on airborne CO2 column absorption measurements made in 2009 with a pulsed direct-detection lidar operating at 1572.33 nm and utilizing the integrated path differential absorption technique. We demonstrated these at different altitudes from an aircraft in July and August in flights over four locations in the central and eastern United States. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. The lidar measurement statistics were also calculated for each flight as a function of altitude. The optical depth varied nearly linearly with altitude, consistent with calculations based on atmospheric models. The scatter in the optical depth measurements varied with aircraft altitude as expected, and the median measurement precisions for the column varied from 0.9 to 1.2 ppm. The altitude range with the lowest scatter was 810 km, and the majority of measurements for the column within it had precisions between 0.2 and 0.9 ppm.

  17. Validation of an enzyme-linked immunosorbent assay screening method and a liquid chromatography-tandem mass spectrometry confirmation method for the identification and quantification of ketamine and norketamine in urine samples from Malaysia.

    PubMed

    Harun, Norlida; Anderson, Robert A; Miller, Eleanor I

    2009-01-01

    An ELISA and a liquid chromatography-tandem mass spectrometry (LC-MS-MS) confirmation method were developed and validated for the identification and quantitation of ketamine and its major metabolite norketamine in urine samples. The Neogen ketamine microplate ELISA was optimized with respect to sample and enzyme conjugate volumes and the sample preincubation time before addition of the enzyme conjugate. The ELISA kit was validated to include an assessment of the dose-response curve, intra- and interday precision, limit of detection (LOD), and cross-reactivity. The sensitivity and specificity were calculated by comparison to the results from the validated LC-MS-MS confirmation method. An LC-MS-MS method was developed and validated with respect to LOD, lower limit of quantitation (LLOQ), linearity, recovery, intra- and interday precision, and matrix effects. The ELISA dose-response curve was a typical S-shaped binding curve, with a linear portion of the graph observed between 25 and 500 ng/mL for ketamine. The cross-reactivity of 200 ng/mL norketamine to ketamine was 2.1%, and no cross-reactivity was detected with 13 common drugs tested at 10,000 ng/mL. The ELISA LOD was calculated to be 5 ng/mL. Both intra- (n = 10) and interday (n = 50) precisions were below 5.0% at 25 ng/mL. The LOD for ketamine and norketamine was calculated statistically to be 0.6 ng/mL. The LLOQ values were also calculated statistically and were 1.9 ng/mL and 2.1 ng/mL for ketamine and norketamine, respectively. The test linearity was 0-1200 ng/mL with correlation coefficient (R(2)) > 0.99 for both analytes. Recoveries at 50, 500, and 1000 ng/mL range from 97.9% to 113.3%. Intra- (n = 5) and interday (n = 25) precisions between extracts for ketamine and norketamine were excellent (< 10%). Matrix effects analysis showed an average ion suppression of 5.7% for ketamine and an average ion enhancement of 13.0% for norketamine for urine samples collected from six individuals. A comparison of ELISA and LC-MS-MS results demonstrated a sensitivity, specificity, and efficiency of 100%. These results indicated that a cutoff value of 25 ng/mL ketamine in the ELISA screen is particularly suitable and reliable for urine testing in a forensic toxicology setting. Furthermore, both ketamine and norketamine were detected in all 34 urine samples collected from individuals socializing in pubs by the Royal Malaysian Police. Ketamine concentrations detected by LC-MS-MS ranged from 22 to 31,670 ng/mL, and norketamine concentrations ranged from 25 to 10,990 ng/mL. The concentrations of ketamine and norketamine detected in the samples are most ikely indicative of ketamine abuse.

  18. An electron beam linear scanning mode for industrial limited-angle nano-computed tomography.

    PubMed

    Wang, Chengxiang; Zeng, Li; Yu, Wei; Zhang, Lingli; Guo, Yumeng; Gong, Changcheng

    2018-01-01

    Nano-computed tomography (nano-CT), which utilizes X-rays to research the inner structure of some small objects and has been widely utilized in biomedical research, electronic technology, geology, material sciences, etc., is a high spatial resolution and non-destructive research technique. A traditional nano-CT scanning model with a very high mechanical precision and stability of object manipulator, which is difficult to reach when the scanned object is continuously rotated, is required for high resolution imaging. To reduce the scanning time and attain a stable and high resolution imaging in industrial non-destructive testing, we study an electron beam linear scanning mode of nano-CT system that can avoid mechanical vibration and object movement caused by the continuously rotated object. Furthermore, to further save the scanning time and study how small the scanning range could be considered with acceptable spatial resolution, an alternating iterative algorithm based on ℓ 0 minimization is utilized to limited-angle nano-CT reconstruction problem with the electron beam linear scanning mode. The experimental results confirm the feasibility of the electron beam linear scanning mode of nano-CT system.

  19. An electron beam linear scanning mode for industrial limited-angle nano-computed tomography

    NASA Astrophysics Data System (ADS)

    Wang, Chengxiang; Zeng, Li; Yu, Wei; Zhang, Lingli; Guo, Yumeng; Gong, Changcheng

    2018-01-01

    Nano-computed tomography (nano-CT), which utilizes X-rays to research the inner structure of some small objects and has been widely utilized in biomedical research, electronic technology, geology, material sciences, etc., is a high spatial resolution and non-destructive research technique. A traditional nano-CT scanning model with a very high mechanical precision and stability of object manipulator, which is difficult to reach when the scanned object is continuously rotated, is required for high resolution imaging. To reduce the scanning time and attain a stable and high resolution imaging in industrial non-destructive testing, we study an electron beam linear scanning mode of nano-CT system that can avoid mechanical vibration and object movement caused by the continuously rotated object. Furthermore, to further save the scanning time and study how small the scanning range could be considered with acceptable spatial resolution, an alternating iterative algorithm based on ℓ0 minimization is utilized to limited-angle nano-CT reconstruction problem with the electron beam linear scanning mode. The experimental results confirm the feasibility of the electron beam linear scanning mode of nano-CT system.

  20. SU-E-T-451: Accuracy and Application of the Standard Imaging W1 Scintillator Dosimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kowalski, M; McEwen, M

    2014-06-01

    Purpose: To evaluate the Standard Imaging W1 scintillator dosimeter in a range of clinical radiation beams to determine its range of possible applications. Methods: The W1 scintillator is a small perturbation-free dosimeter which is of interest in absolute and relative clinical dosimetry due to its small size and water equivalence. A single version of this detector was evaluated in Co-60 and linac photon and electron beams to investigate the following: linearity, sensitivity, precision, and dependence on electrometer type. In addition, depth-dose and cross-plane profiles were obtained in both photon and electron beams and compared with data obtained with wellbehaved ionizationmore » chambers. Results: In linac beams the precision and linearity was very impressive, with typical values of 0.3% and 0.1% respectively. Performance in a Co-60 beam was much poorer (approximately three times worse) and it is not clear whether this is due to the lower signal current or the effect of the continuous beam (rather than pulsed beam of the linac measurements). There was no significant difference in the detector reading when using either the recommended SI Supermax electrometer or two independent high-quality electrometers, except for low signal levels, where the Supermax exhibited an apparent threshold effect, preventing the measurement of the bremsstrahlung background in electron depth-dose curves. Comparisons with ion chamber measurements in linac beams were somewhat variable: good agreement was seen for cross-profiles (photon and electron beams) and electron beam depth-dose curves, generally within the 0.3% precision of the scintillator but systematic differences were observed as a function of measurement depth in photon beam depth-dose curves. Conclusion: A first look would suggest that the W1 scintillator has applications beyond small field dosimetry but performance appears to be limited to higher doserate and/or pulsed radiation beams. Further work is required to resolve discrepancies compared to ion chambers.« less

  1. Determination of Bortezomib in API Samples Using HPLC: Assessment of Enantiomeric and Diastereomeric Impurities.

    PubMed

    Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein

    2017-08-01

    A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were <1.0%. System suitability parameters in terms of tailing factor (TF), number of theoretical plates (N) and RS were TF < 2.0, N > 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Solid phase extraction with high polarity Carb/PSA as composite fillers prior to UPLC-MS/MS to determine six bisphenols and alkylphenols in trace level hotpot seasoning.

    PubMed

    Dong, Hao; Zeng, Xiaofang; Bai, Weidong

    2018-08-30

    The present study reports an ultra high-performance liquid chromatography tandem mass spectrometry method for the simultaneous determination of six bisphenols (bisphenol A, bisphenol B and bisphenol F) and alkylphenols (4-nonylphenol, 4-n-nonylphenol and octylphenol) in hotpot seasoning. Samples were dispersed in n-hexane after addition of internal standards bisphenol A-d 4 and 4-n-nonylphenol-d 4 . Sample solutions were then centrifuged, and the supernatants purified using solid phase extraction with high polarity Carb/PSA composite fillers. Six target analytes were separated on a Waters ACQUITY BEH C18 column by gradient elution with methanol and 0.05% ammonium hydroxide in water as the mobile phase, and determined under multiple reactions monitoring mode. The limits of detection and quantitation, matrix effect, recovery and precision of the method were investigated. Results were linear in the concentration range 0.1-250 µg/L for all compounds of interest, with R 2  > 0.9950. Limits of detection were in the range 0.1-0.4 μg/kg, and limits of quantitation were between 0.5 μg/kg and 1.0 μg/kg. The mean recoveries for negative samples at three spiked concentrations were in the range 87.9%-102.4%, and the intra-day precision and inter-day precision were in the ranges 2.1-8.2% and 4.8-11.2%, respectively. This method is accurate and sensitive, and had good clean-up characteristics, which might apply to screening and quantitation of target bisphenols and alkylphenols in hotpot seasoning. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Validation of a liquid chromatography-tandem mass spectrometry method for the identification and quantification of 5-nitroimidazole drugs and their corresponding hydroxy metabolites in lyophilised pork meat.

    PubMed

    Zeleny, Reinhard; Harbeck, Stefan; Schimmel, Heinz

    2009-01-09

    A liquid chromatography-electrospray ionisation tandem mass spectrometry method for the simultaneous detection and quantitation of 5-nitroimidazole veterinary drugs in lyophilised pork meat, the chosen format of a candidate certified reference material, has been developed and validated. Six analytes have been included in the scope of validation, i.e. dimetridazole (DMZ), metronidazole (MNZ), ronidazole (RNZ), hydroxymetronidazole (MNZOH), hydroxyipronidazole (IPZOH), and 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI). The analytes were extracted from the sample with ethyl acetate, chromatographically separated on a C(18) column, and finally identified and quantified by tandem mass spectrometry in the multiple reaction monitoring mode (MRM) using matrix-matched calibration and (2)H(3)-labelled analogues of the analytes (except for MNZOH, where [(2)H(3)]MNZ was used). The method was validated in accordance with Commission Decision 2002/657/EC, by determining selectivity, linearity, matrix effect, apparent recovery, repeatability and intermediate precision, decision limits and detection capabilities, robustness of sample preparation method, and stability of extracts. Recovery at 1 microg/kg level was at 100% (estimates in the range of 101-107%) for all analytes, repeatabilities and intermediate precisions at this level were in the range of 4-12% and 2-9%, respectively. Linearity of calibration curves in the working range 0.5-10 microg/kg was confirmed, with r values typically >0.99. Decision limits (CCalpha) and detection capabilities (CCbeta) according to ISO 11843-2 (calibration curve approach) were 0.29-0.44 and 0.36-0.54 microg/kg, respectively. The method reliably identifies and quantifies the selected nitroimidazoles in the reconstituted pork meat in the low and sub-microg/kg range and will be applied in an interlaboratory comparison for determining the mass fraction of the selected nitroimidazoles in the candidate reference material currently developed at IRMM.

  4. Precision linear ramp function generator

    DOEpatents

    Jatko, W.B.; McNeilly, D.R.; Thacker, L.H.

    1984-08-01

    A ramp function generator is provided which produces a precise linear ramp function which is repeatable and highly stable. A derivative feedback loop is used to stabilize the output of an integrator in the forward loop and control the ramp rate. The ramp may be started from a selected baseline voltage level and the desired ramp rate is selected by applying an appropriate constant voltage to the input of the integrator.

  5. Precision linear ramp function generator

    DOEpatents

    Jatko, W. Bruce; McNeilly, David R.; Thacker, Louis H.

    1986-01-01

    A ramp function generator is provided which produces a precise linear ramp unction which is repeatable and highly stable. A derivative feedback loop is used to stabilize the output of an integrator in the forward loop and control the ramp rate. The ramp may be started from a selected baseline voltage level and the desired ramp rate is selected by applying an appropriate constant voltage to the input of the integrator.

  6. Complex thiolated mannose/quinone film modified on EQCM/Au electrode for recognizing specific carbohydrate-proteins.

    PubMed

    Zeng, Hongjuan; Yu, Junsheng; Jiang, Yadong; Zeng, Xiangqun

    2014-05-15

    A complex thiolated mannose (TM)/quinone functionalised polythiophene (QFPT) thin film was modified on EQCM/Au electrode for recognition of specific carbohydrate-proteins. Different lectins such as those from Sambucus nigra (elder berry), Arachis hypogaea (peanut), Ulex europaeus (gorse, furze), Triticum vulgaris and Concanavalin A (ConA) was used for probes to evaluate bio-sensing performance of the TM/QFPT film. A specific response was observed for ConA from lectins when using the TM/QFPT film as sensing material and employing either elelctrochemical or the QCM method. No response was detected between thiolated mannose and other lectins. The linear relationship between current and ConA concentration is in the range of 0.5-17.5 nM by the elelctrochemical method and the linear relationship between frequency change and ConA concentration is in the range of 0.5-4.5 nM by the QCM method. This shows that the TM/QFPT-modified EQCM biosensor presents a paralleled determination by using electrochemical and the QCM method. The elelctrochemical method of the biosensor can be applicable in a large concentration range and its frequency change can be more precise. © 2013 Published by Elsevier B.V.

  7. Linearized lattice Boltzmann method for micro- and nanoscale flow and heat transfer.

    PubMed

    Shi, Yong; Yap, Ying Wan; Sader, John E

    2015-07-01

    Ability to characterize the heat transfer in flowing gases is important for a wide range of applications involving micro- and nanoscale devices. Gas flows away from the continuum limit can be captured using the Boltzmann equation, whose analytical solution poses a formidable challenge. An efficient and accurate numerical simulation of the Boltzmann equation is thus highly desirable. In this article, the linearized Boltzmann Bhatnagar-Gross-Krook equation is used to develop a hierarchy of thermal lattice Boltzmann (LB) models based on half-space Gaussian-Hermite (GH) quadrature ranging from low to high algebraic precision, using double distribution functions. Simplified versions of the LB models in the continuum limit are also derived, and are shown to be consistent with existing thermal LB models for noncontinuum heat transfer reported in the literature. Accuracy of the proposed LB hierarchy is assessed by simulating thermal Couette flows for a wide range of Knudsen numbers. Effects of the underlying quadrature schemes (half-space GH vs full-space GH) and continuum-limit simplifications on computational accuracy are also elaborated. The numerical findings in this article provide direct evidence of improved computational capability of the proposed LB models for modeling noncontinuum flows and heat transfer at small length scales.

  8. Tramadol chronic abuse: an evidence from hair analysis by LC tandem MS.

    PubMed

    Verri, Patrizia; Rustichelli, Cecilia; Palazzoli, Federica; Vandelli, Daniele; Marchesi, Filippo; Ferrari, Anna; Licata, Manuela

    2015-01-01

    Hair analysis, as complementary matrix, has expanded across the spectrum of toxicological investigations for misuse drug monitoring. Hair has become an important matrix for drug analysis, owing to the possibility to detect target analytes for long time periods, depending on hair length. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for the quantitation of tramadol, a widely used centrally acting analgesic, and its main metabolites in hair (ODMT, NDMT, NOT). Hair samples were decontaminated and incubated overnight in diluted hydrochloric acid; the extracts were purified by mixed-mode solid phase cartridges and analyzed by LC-MS/MS in positive ionization mode monitoring two transitions per analyte. The procedure was fully validated in terms of linearity, limit of detection and lower limit of quantitation (LLOQ), accuracy, precision, recovery, matrix effect and selectivity. The linear regression analysis was calibrated by deuterated internal standards; for all analytes, responses were linear over the range 0.04-40.00 ng/mg hair, with R(2) values of at least 0.995. The method offered satisfactory precision (RSD < 10%), accuracy (90-110%) and recovery (> 90%) values. The found LLOQ values for tramadol and metabolites were in the range 0.010-0.030 ng/mg hair. The proposed procedure was successfully applied to quantify tramadol and metabolites in real hair samples submitted to our laboratory: three cases of tramadol assumption within the therapeutic dosage (3 × 2 segments) and one case of tramadol abuse in a binge pattern (8 segments). The ranges found for TRAM, ODMT, NDMT and NOT were markedly higher in the abuse case (63.42-107.30, 3.76-6.26, 24.88-45.66, 0.22-1.18 ng/mg hair, respectively) compared to the other case reports (3.29-20.12, 0.28-1.87, 0.45-4.32, 0.07-0.80 ng/mg, respectively); also the values of NMDT/ODMT ratio differed significantly. According to the obtained data, we hypothesized that the binge pattern may influence the metabolites' to parent drug concentration ratios; therefore this parameter could represent a target assessment tool to monitor abuse cases. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. The compression–error trade-off for large gridded data sets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silver, Jeremy D.; Zender, Charles S.

    The netCDF-4 format is widely used for large gridded scientific data sets and includes several compression methods: lossy linear scaling and the non-lossy deflate and shuffle algorithms. Many multidimensional geoscientific data sets exhibit considerable variation over one or several spatial dimensions (e.g., vertically) with less variation in the remaining dimensions (e.g., horizontally). On such data sets, linear scaling with a single pair of scale and offset parameters often entails considerable loss of precision. We introduce an alternative compression method called "layer-packing" that simultaneously exploits lossy linear scaling and lossless compression. Layer-packing stores arrays (instead of a scalar pair) of scalemore » and offset parameters. An implementation of this method is compared with lossless compression, storing data at fixed relative precision (bit-grooming) and scalar linear packing in terms of compression ratio, accuracy and speed. When viewed as a trade-off between compression and error, layer-packing yields similar results to bit-grooming (storing between 3 and 4 significant figures). Bit-grooming and layer-packing offer significantly better control of precision than scalar linear packing. Relative performance, in terms of compression and errors, of bit-groomed and layer-packed data were strongly predicted by the entropy of the exponent array, and lossless compression was well predicted by entropy of the original data array. Layer-packed data files must be "unpacked" to be readily usable. The compression and precision characteristics make layer-packing a competitive archive format for many scientific data sets.« less

  10. The compression–error trade-off for large gridded data sets

    DOE PAGES

    Silver, Jeremy D.; Zender, Charles S.

    2017-01-27

    The netCDF-4 format is widely used for large gridded scientific data sets and includes several compression methods: lossy linear scaling and the non-lossy deflate and shuffle algorithms. Many multidimensional geoscientific data sets exhibit considerable variation over one or several spatial dimensions (e.g., vertically) with less variation in the remaining dimensions (e.g., horizontally). On such data sets, linear scaling with a single pair of scale and offset parameters often entails considerable loss of precision. We introduce an alternative compression method called "layer-packing" that simultaneously exploits lossy linear scaling and lossless compression. Layer-packing stores arrays (instead of a scalar pair) of scalemore » and offset parameters. An implementation of this method is compared with lossless compression, storing data at fixed relative precision (bit-grooming) and scalar linear packing in terms of compression ratio, accuracy and speed. When viewed as a trade-off between compression and error, layer-packing yields similar results to bit-grooming (storing between 3 and 4 significant figures). Bit-grooming and layer-packing offer significantly better control of precision than scalar linear packing. Relative performance, in terms of compression and errors, of bit-groomed and layer-packed data were strongly predicted by the entropy of the exponent array, and lossless compression was well predicted by entropy of the original data array. Layer-packed data files must be "unpacked" to be readily usable. The compression and precision characteristics make layer-packing a competitive archive format for many scientific data sets.« less

  11. Simultaneous quantification and semi-quantification of ginkgolic acids and their metabolites in rat plasma by UHPLC-LTQ-Orbitrap-MS and its application to pharmacokinetics study.

    PubMed

    Qian, Yiyun; Zhu, Zhenhua; Duan, Jin-Ao; Guo, Sheng; Shang, Erxin; Tao, Jinhua; Su, Shulan; Guo, Jianming

    2017-01-15

    A highly sensitive method using ultra-high-pressure liquid chromatography coupled with linear ion trap-Orbitrap tandem mass spectrometry (UHPLC-LTQ-Orbitrap-MS) has been developed and validated for the simultaneous identification and quantification of ginkgolic acids and semi-quantification of their metabolites in rat plasma. For the five selected ginkgolic acids, the method was found to be with good linearities (r>0.9991), good intra- and inter-day precisions (RSD<15%), and good accuracies (RE, from -10.33% to 4.92%) as well. Extraction recoveries, matrix effects and stabilities for rat plasm samples were within the required limits. The validated method was successfully applied to investigate the pharmacokinetics of the five ginkgolic acids in rat plasma after oral administration of 3 dosage groups (900mg/kg, 300mg/kg and 100mg/kg). Meanwhile, six metabolites of GA (15:1) and GA (17:1) were identified by comparison of MS data with reported values. The results of validation in terms of linear ranges, precisions and stabilities were established for semi-quantification of metabolites. The curves of relative changes of these metabolites during the metabolic process were constructed by plotting the peak area ratios of metabolites to salicylic acid (internal standard, IS), respectively. Double peaks were observed in all 3 dose groups. Different type of metabolites and different dosage of each metabolite both resulted in different T max . Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Precision measurement of the local bias of dark matter halos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lazeyras, Titouan; Wagner, Christian; Schmidt, Fabian

    2016-02-01

    We present accurate measurements of the linear, quadratic, and cubic local bias of dark matter halos, using curved 'separate universe' N-body simulations which effectively incorporate an infinite-wavelength overdensity. This can be seen as an exact implementation of the peak-background split argument. We compare the results with the linear and quadratic bias measured from the halo-matter power spectrum and bispectrum, and find good agreement. On the other hand, the standard peak-background split applied to the Sheth and Tormen (1999) and Tinker et al. (2008) halo mass functions matches the measured linear bias parameter only at the level of 10%. The predictionmore » from the excursion set-peaks approach performs much better, which can be attributed to the stochastic moving barrier employed in the excursion set-peaks prediction. We also provide convenient fitting formulas for the nonlinear bias parameters b{sub 2}(b{sub 1}) and b{sub 3}(b{sub 1}), which work well over a range of redshifts.« less

  13. Microhartree precision in density functional theory calculations

    NASA Astrophysics Data System (ADS)

    Gulans, Andris; Kozhevnikov, Anton; Draxl, Claudia

    2018-04-01

    To address ultimate precision in density functional theory calculations we employ the full-potential linearized augmented plane-wave + local-orbital (LAPW + lo) method and justify its usage as a benchmark method. LAPW + lo and two completely unrelated numerical approaches, the multiresolution analysis (MRA) and the linear combination of atomic orbitals, yield total energies of atoms with mean deviations of 0.9 and 0.2 μ Ha , respectively. Spectacular agreement with the MRA is reached also for total and atomization energies of the G2-1 set consisting of 55 molecules. With the example of α iron we demonstrate the capability of LAPW + lo to reach μ Ha /atom precision also for periodic systems, which allows also for the distinction between the numerical precision and the accuracy of a given functional.

  14. Development, validation and application of a SDME/GC-FID methodology for the multiresidue determination of organophosphate and pyrethroid pesticides in water.

    PubMed

    Pinheiro, Anselmo de Souza; de Andrade, Jailson B

    2009-10-15

    A single-drop microextraction (SDME) procedure was developed for the analysis of organophosphorus and pyrethroid pesticides in water by gas chromatography (GC) with flame ionization detection (GC-FID). The significant parameters that affect SDME performance, such as the selection of microextraction solvent, solvent volume, extraction time, and stirring rate, were studied and optimized using a tool screening factorial design. The limits of detection (LODs) in water for the four investigated compounds were between 0.3 and 3.0 microgL(-1), with relative standard deviations ranging from 7.7 to 18.8%. Linear response data were obtained in the concentration range of 0.9-6.0 microg L(-1) (lambda-cyhalothrin), 3.0-60.0 microg L(-1) (methyl parathion), 9.0-60.0 microg L(-1) (ethion), and 9.0-30.0 microg L(-1) (permethrin), with correlation coefficients ranging from 0.9337 to 0.9977. The relative recoveries for the spiked water ranged from 73.0 to 104%. Environmental water samples (n=26) were successfully analyzed using the proposed method and methyl parathion presented concentration up to 2.74 microg L(-1). The SDME method, coupled with GC-FID analysis, provided good precision, accuracy, and reproducibility over a wide linear range. Other highlights of the method include its ease of use and its requirement of only small volumes of both organic solvent and sample.

  15. Precise measurement of coupling strength and high temperature quantum effect in a nonlinearly coupled qubit-oscillator system

    NASA Astrophysics Data System (ADS)

    Ge, Li; Zhao, Nan

    2018-04-01

    We study the coherence dynamics of a qubit coupled to a harmonic oscillator with both linear and quadratic interactions. As long as the linear coupling strength is much smaller than the oscillator frequency, the long time behavior of the coherence is dominated by the quadratic coupling strength g 2. The coherence decays and revives at a period , with the width of coherence peak decreasing as the temperature increases, hence providing a way to measure g 2 precisely without cooling. Unlike the case of linear coupling, here the coherence dynamics never reduces to the classical limit in which the oscillator is classical. Finally, the validity of linear coupling approximation is discussed and the coherence under Hahn-echo is evaluated.

  16. Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum

    PubMed Central

    Ciltas, Ulvihan; Yilmaz, Bilal; Kaban, Selcuk; Akcay, Bilge Kaan; Nazik, Gulsah

    2015-01-01

    In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL-1 and 2-20 μg mL-1 in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum. PMID:26330859

  17. Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum.

    PubMed

    Ciltas, Ulvihan; Yilmaz, Bilal; Kaban, Selcuk; Akcay, Bilge Kaan; Nazik, Gulsah

    2015-01-01

    In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL(-1) and 2-20 μg mL(-1) in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum.

  18. Novel spectrophotometric methods for simultaneous determination of timolol and dorzolamide in their binary mixture.

    PubMed

    Lotfy, Hayam Mahmoud; Hegazy, Maha A; Rezk, Mamdouh R; Omran, Yasmin Rostom

    2014-05-21

    Two smart and novel spectrophotometric methods namely; absorbance subtraction (AS) and amplitude modulation (AM) were developed and validated for the determination of a binary mixture of timolol maleate (TIM) and dorzolamide hydrochloride (DOR) in presence of benzalkonium chloride without prior separation, using unified regression equation. Additionally, simple, specific, accurate and precise spectrophotometric methods manipulating ratio spectra were developed and validated for simultaneous determination of the binary mixture namely; simultaneous ratio subtraction (SRS), ratio difference (RD), ratio subtraction (RS) coupled with extended ratio subtraction (EXRS), constant multiplication method (CM) and mean centering of ratio spectra (MCR). The proposed spectrophotometric procedures do not require any separation steps. Accuracy, precision and linearity ranges of the proposed methods were determined and the specificity was assessed by analyzing synthetic mixtures of both drugs. They were applied to their pharmaceutical formulation and the results obtained were statistically compared to that of a reported spectrophotometric method. The statistical comparison showed that there is no significant difference between the proposed methods and the reported one regarding both accuracy and precision. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. A comparative study of smart spectrophotometric methods for simultaneous determination of a skeletal muscle relaxant and an analgesic in combined dosage form

    NASA Astrophysics Data System (ADS)

    Salem, Hesham; Mohamed, Dalia

    2015-04-01

    Six simple, specific, accurate and precise spectrophotometric methods were developed and validated for the simultaneous determination of the analgesic drug; paracetamol (PARA) and the skeletal muscle relaxant; dantrolene sodium (DANT). Three methods are manipulating ratio spectra namely; ratio difference (RD), ratio subtraction (RS) and mean centering (MC). The other three methods are utilizing the isoabsorptive point either at zero order namely; absorbance ratio (AR) and absorbance subtraction (AS) or at ratio spectrum namely; amplitude modulation (AM). The proposed spectrophotometric procedures do not require any preliminary separation step. The accuracy, precision and linearity ranges of the proposed methods were determined. The selectivity of the developed methods was investigated by analyzing laboratory prepared mixtures of the drugs and their combined dosage form. Standard deviation values are less than 1.5 in the assay of raw materials and capsules. The obtained results were statistically compared with each other and with those of reported spectrophotometric ones. The comparison showed that there is no significant difference between the proposed methods and the reported methods regarding both accuracy and precision.

  20. Simultaneous Quantification of Gymnemic Acid as Gymnemagenin and Charantin as β-Sitosterol Using Validated HPTLC Densitometric Method.

    PubMed

    Ahamad, Javed; Amin, Saima; Mir, Showkat R

    2015-08-01

    Gymnemic acid and charantin are well-established antidiabetic phytosterols found in Gymnema sylvestre and Momordica charantia, respectively. The fact that these plants are often used together in antidiabetic poly-herbal formulations lured us to develop an HPTLC densitometric method for the simultaneous quantification of their bioactive compounds. Indirect estimation of gymnemic acid as gymnemagenin and charantin as β-sitosterol after hydrolysis has been proposed. Aluminum-backed silica gel 60 F254 plates (20 × 10 cm) were used as stationary phase and toluene-ethyl acetate-methanol-formic acid (60 : 20 : 15 : 5, v/v) as mobile phase. Developed chromatogram was scanned at 550 nm after derivatization with modified vanillin-sulfuric acid reagent. Regression analysis of the calibration data showed an excellent linear relationship between peak area versus concentration of the analytes. Linearity was found to be in the range of 500-2,500 and 100-500 ng/band for gymnemagenin and β-sitosterol, respectively. The suitability of the developed HPTLC method for simultaneous estimation of analytes was established by validating it as per the ICH guidelines. The limits of detection and quantification for gymnemagenin were found to be ≈60 and ≈190 ng/band, and those for β-sitosterol ≈30 and ≈90 ng/band, respectively. The developed method was found to be linear (r(2) = 0.9987 and 0.9943), precise (relative standard deviation <1.5 and <2% for intra- and interday precision) and accurate (mean recovery ranged between 98.43-101.44 and 98.68-100.20%) for gymnemagenin and β-sitosterol, respectively. The proposed method was also found specific and robust for quantification of both the analytes and was successfully applied to herbal drugs and in-house herbal formulation without any interference. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. A new LC-MS/MS bioanalytical method for atenolol in human plasma and milk.

    PubMed

    Phyo Lwin, Ei Mon; Gerber, Cobus; Song, Yunmei; Leggett, Catherine; Ritchie, Usha; Turner, Sean; Garg, Sanjay

    2017-04-01

    A new sensitive LC-MS/MS method for the quantification of atenolol in human plasma and milk has been developed for clinical lactation studies. Atenolol and the internal standard, phenazone, were extracted from biological matrices by protein precipitation. A Phenomenex ® C-18 column and gradient chromatographic conditions were used for separation of the analyte, followed by detection with MS. Stability of samples was confirmed for atenolol in human plasma and milk for up to 3 months. Linearity range of 1-800 ng/ml (r 2 = 0.9995), the precision within 15% CV and the recovery of the analyte (80-100% range) were achieved. A new validated analytical method for atenolol in plasma and milk was developed.

  2. Monitoring of cyclosporine concentrations by using dry blood-spot samples.

    PubMed

    Mee, A V; Wong, P Y; Sun, C; Oei, L; Elliott, S; Naik, N; Joaquin, B; Uchimaru, D

    1991-01-01

    We modified the Incstar Cyclo Trac SP kit to enable its use with dry blood-spots on filter paper. The recovery ranged from 92 to 106%. Dilution studies have shown excellent linearity and parallelism throughout the range of the assay. Precision is demonstrated by within-assay CV's of 6.6 and 4.3% at 96 and 342 micrograms/L respectively and between-assay CV's of 9.1 and 7.0% at 138 and 506 micrograms/L respectively. A comparison study (n = 209) with whole blood assay gave a correlation coefficient of 0.97, a slope of 1.04, and an intercept of 13.2. Whole blood and dry blood-spot cyclosporine assays on heart, kidney, liver, and lung transplants were also compared.

  3. Rapid and sensitive spectrofluorimetric determination of enrofloxacin, levofloxacin and ofloxacin with 2,3,5,6-tetrachloro- p-benzoquinone

    NASA Astrophysics Data System (ADS)

    Ulu, Sevgi Tatar

    2009-06-01

    A highly sensitive spectrofluorimetric method was developed for the first time, for the analysis of three fluoroquinolones (FQ) antibacterials, namely enrofloxacin (ENR), levofloxacin (LEV) and ofloxacin (OFL) in pharmaceutical preparations through charge transfer (CT) complex formation with 2,3,5,6-tetrachloro- p-benzoquinone (chloranil,CLA). At the optimum reaction conditions, the FQ-CLA complexes showed excitation maxima ranging from 359 to 363 nm and emission maxima ranging from 442 to 488 nm. Rectilinear calibration graphs were obtained in the concentration range of 50-1000, 50-1000 and 25-500 ng mL -1 for ENR, LEV and OFL, respectively. The detection limit was found to be 17 ng mL -1 for ENR, 17 ng mL -1 for LEV, 8 ng mL -1 for OFL, respectively. Excipients used as additive in commercial formulations did not interfere in the analysis. The method was validated according to the ICH guidelines with respect to specificity, linearity, accuracy, precision and robustness. The proposed method was successfully applied to the analysis of pharmaceutical preparations. The results obtained were in good agreement with those obtained using the official method; no significant difference in the accuracy and precision as revealed by the accepted values of t- and F-tests, respectively.

  4. Development of a fast LC-MS/MS assay for the determination of deferiprone in human plasma and application to pharmacokinetics.

    PubMed

    Song, Ta-Shu; Hsieh, Yow-Wen; Peng, Ching-Tien; Liu, Cheng-Hsiung; Chen, Tai-Lin; Hour, Mann-Jen

    2012-12-01

    A fast and accurate liquid chromatography/tandem mass spectrometric (LC-MS/MS) assay was first developed and validated for the determination of deferiprone in human plasma. The analytes were extracted with acetonitrile from only 50 μL aliquots of human plasma to achieve the protein precipitation. After extraction, chromatographic separation of analytes in human plasma was performed using a Synergi Fusion-RP 80A column at 30 °C. The mobile phase consisted of methanol and 0.2% formic acid containing 0.2 mM EDTA (60:40, v/v). The flow rate of the mobile phase was 0.8 mL/min. The total run time for each sample analysis was 4 min. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the precursor-to-parent ion transitions m/z 140.1 → 53.1 for deferiprone and m/z 143.1 → 98.1 for internal standard. A linear range was established from 0.1 to 20 µg/mL. The limit of detection was determined as 0.05 µg/mL. The validated method was estimated for linearity, recovery, stability, precision and accuracy. Intraday and interday precisions were 4.3-5.5 and 4.6-7.3%, respectively. The recovery of deferiprone was in the range of 80.1-86.8%. The method was successfully applied to a pharmacokinetic study of deferiprone in six thalassemia patients. Copyright © 2012 John Wiley & Sons, Ltd.

  5. Quantitative determination of acidic hydrolysis products of Chemical Weapons Convention related chemicals from aqueous and soil samples using ion-pair solid-phase extraction and in situ butylation.

    PubMed

    Pal Anagoni, Suresh; Kauser, Asma; Maity, Gopal; Upadhyayula, Vijayasarathi V R

    2018-02-01

    Chemical warfare agents such as organophosphorus nerve agents, mustard agents, and psychotomimetic agent like 3-quinuclidinylbenzilate degrade in the environment and form acidic degradation products, the analysis of which is difficult under normal analytical conditions. In the present work, a simultaneous extraction and derivatization method in which the analytes are butylated followed by gas chromatography and mass spectrometric identification of the analytes from aqueous and soil samples was carried out. The extraction was carried out using ion-pair solid-phase extraction with tetrabutylammonium hydroxide followed by gas chromatography with mass spectrometry in the electron ionization mode. Various parameters such as optimum concentration of the ion-pair reagent, pH of the sample, extraction solvent, and type of ion-pair reagent were optimized. The method was validated for various parameters such as linearity, accuracy, precision, and limit of detection and quantification. The method was observed to be linear from 1 to 1000 ng/mL range in selected ion monitoring mode. The extraction recoveries were in the range of 85-110% from the matrixes with the limit of quantification for alkyl phosphonic acids at 1 ng/mL, thiodiglycolic acid at 20 ng/mL, and benzilic acid at 50 ng/mL with intra- and interday precisions below 15%. The developed method was applied for the samples prepared in the scenario of challenging inspection. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. An ultra-high performance liquid chromatography method to determine the skin penetration of an octyl methoxycinnamate-loaded liquid crystalline system.

    PubMed

    Prado, A H; Borges, M C; Eloy, J O; Peccinini, R G; Chorilli, M

    2017-10-01

    Cutaneous penetration is a critical factor in the use of sunscreen, as the compounds should not reach systemic circulation in order to avoid the induction of toxicity. The evaluation of the skin penetration and permeation of the UVB filter octyl methoxycinnamate (OMC) is essential for the development of a successful sunscreen formulation. Liquid-crystalline systems are innovative and potential carriers of OMC, which possess several advantages, including controlled release and protection of the filter from degradation. In this study, a new and effective method was developed using ultra-high performance liquid chromatography (UPLC) with ultraviolet detection (UV) for the quantitative analysis of penetration of OMC-loaded liquid crystalline systems into the skin. The following parameters were assessed in the method: selectivity, linearity, precision, accuracy, robustness, limit of detection (LOD), and limit of quantification (LOQ). The analytical curve was linear in the range from 0.25 to 250 μg.m-1, precise, with a standard deviation of 0.05-1.24%, with an accuracy in the range from 96.72 to 105.52%, and robust, with adequate values for the LOD and LOQ of 0.1 and 0.25 μg.mL -1, respectively. The method was successfully used to determine the in vitro skin permeation of OMC-loaded liquid crystalline systems. The results of the in vitro tests on Franz cells showed low cutaneous permeation and high retention of the OMC, particularly in the stratum corneum, owing to its high lipophilicity, which is desirable for a sunscreen formulation.

  7. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    PubMed

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  8. Linear electrostatic micromotors for nano- and micro-positioning

    NASA Astrophysics Data System (ADS)

    Baginsky, I. L.; Kostsov, Edvard G.

    2004-05-01

    The functioning of the linear step electrostatic film micromotors with the short controlling pulse (less then 100-200 ´s) is studied to create nano- and micro-positioners. The theoretical study of the step movement of the given mass in this time frame is carried out. The results of the experimental studies of the multipetal reciprocal micromotors created on the basis of La modified Ba0.5Sr0.5Nb2O6 ferroelectric films with 1-3 μm thickness are shown. The petals were made of beryllium bronze. It is shown that the electrostatic rolling can last less than 50 μs, and the process of separating two surfaces (the metal and the ferroelectric) can last less than 1 μs. These parameters allow one to operate the micromotor at 1-10 kHz frequency, and the propulsion force in the beginning (the first 20-100 μs) of the electrostatic rolling can be as high as 1-10 N per 1 mm2 of the rolling surface with the voltage pulse amplitude of 40-50 V. The possibility of obtaining moving plate (MP) step in the nanometer range is studied, as well as the precision of these steps during the continuous MP movement with the different clock frequencies and durations of the voltage pulses. The recommendations are given to improve the accuracy and the speed of the positioning in the nano- and micro-movement range. Possible fields of micromotor application are micromechanics, including precision micromechanics, microelectronics, microrobots, microoptics, microscanners, micropumps (e.g. in the jet printers), micro flying vehicles etc.

  9. Comparison of UV spectrophotometry and high performance liquid chromatography methods for the determination of repaglinide in tablets.

    PubMed

    Dhole, Seema M; Khedekar, Pramod B; Amnerkar, Nikhil D

    2012-07-01

    Repaglinide is a miglitinide class of antidiabetic drug used for the treatment of type 2 diabetes mellitus. A fast and reliable method for the determination of repaglinide was highly desirable to support formulation screening and quality control. UV spectrophotometric and reversed-phase high performance liquid chromatography (RP-HPLC) methods were developed for determination of repaglinide in the tablet dosage form. The UV spectrum recorded between 200 400 nm using methanol as solvent and the wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted to 3.5 with orthophosphoric acid) at a flow rate of 1.0 ml/min. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the International Conference on Harmonization (ICH) guidelines. The developed methods illustrated excellent linearity (r(2) > 0.999) in the concentration range of 5-30 μg/ml and 5-50 μg/ml for UV spectrophotometric and HPLC methods, respectively. Precision (%R.S.D < 1.50) and mean recoveries were found in the range of 99.63-100.45% for UV spectrophotometric method and 99.71-100.25% for HPLC method which shows accuracy of the methods. The developed methods were found to be reliable, simple, fast, accurate and successfully used for the quality control of repaglinide as a bulk drug and in pharmaceutical formulations.

  10. Comparison of UV spectrophotometry and high performance liquid chromatography methods for the determination of repaglinide in tablets

    PubMed Central

    Dhole, Seema M.; Khedekar, Pramod B.; Amnerkar, Nikhil D.

    2012-01-01

    Background: Repaglinide is a miglitinide class of antidiabetic drug used for the treatment of type 2 diabetes mellitus. A fast and reliable method for the determination of repaglinide was highly desirable to support formulation screening and quality control. Objective: UV spectrophotometric and reversed-phase high performance liquid chromatography (RP-HPLC) methods were developed for determination of repaglinide in the tablet dosage form. Materials and Methods: The UV spectrum recorded between 200 400 nm using methanol as solvent and the wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted to 3.5 with orthophosphoric acid) at a flow rate of 1.0 ml/min. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the International Conference on Harmonization (ICH) guidelines. Results: The developed methods illustrated excellent linearity (r2 > 0.999) in the concentration range of 5-30 μg/ml and 5-50 μg/ml for UV spectrophotometric and HPLC methods, respectively. Precision (%R.S.D < 1.50) and mean recoveries were found in the range of 99.63-100.45% for UV spectrophotometric method and 99.71-100.25% for HPLC method which shows accuracy of the methods. Conclusion: The developed methods were found to be reliable, simple, fast, accurate and successfully used for the quality control of repaglinide as a bulk drug and in pharmaceutical formulations. PMID:23781481

  11. Validated spectrophotometric methods for determination of sodium valproate based on charge transfer complexation reactions.

    PubMed

    Belal, Tarek S; El-Kafrawy, Dina S; Mahrous, Mohamed S; Abdel-Khalek, Magdi M; Abo-Gharam, Amira H

    2016-02-15

    This work presents the development, validation and application of four simple and direct spectrophotometric methods for determination of sodium valproate (VP) through charge transfer complexation reactions. The first method is based on the reaction of the drug with p-chloranilic acid (p-CA) in acetone to give a purple colored product with maximum absorbance at 524nm. The second method depends on the reaction of VP with dichlone (DC) in dimethylformamide forming a reddish orange product measured at 490nm. The third method is based upon the interaction of VP and picric acid (PA) in chloroform resulting in the formation of a yellow complex measured at 415nm. The fourth method involves the formation of a yellow complex peaking at 361nm upon the reaction of the drug with iodine in chloroform. Experimental conditions affecting the color development were studied and optimized. Stoichiometry of the reactions was determined. The proposed spectrophotometric procedures were effectively validated with respect to linearity, ranges, precision, accuracy, specificity, robustness, detection and quantification limits. Calibration curves of the formed color products with p-CA, DC, PA and iodine showed good linear relationships over the concentration ranges 24-144, 40-200, 2-20 and 1-8μg/mL respectively. The proposed methods were successfully applied to the assay of sodium valproate in tablets and oral solution dosage forms with good accuracy and precision. Assay results were statistically compared to a reference pharmacopoeial HPLC method where no significant differences were observed between the proposed methods and reference method. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Validated spectrophotometric methods for determination of sodium valproate based on charge transfer complexation reactions

    NASA Astrophysics Data System (ADS)

    Belal, Tarek S.; El-Kafrawy, Dina S.; Mahrous, Mohamed S.; Abdel-Khalek, Magdi M.; Abo-Gharam, Amira H.

    2016-02-01

    This work presents the development, validation and application of four simple and direct spectrophotometric methods for determination of sodium valproate (VP) through charge transfer complexation reactions. The first method is based on the reaction of the drug with p-chloranilic acid (p-CA) in acetone to give a purple colored product with maximum absorbance at 524 nm. The second method depends on the reaction of VP with dichlone (DC) in dimethylformamide forming a reddish orange product measured at 490 nm. The third method is based upon the interaction of VP and picric acid (PA) in chloroform resulting in the formation of a yellow complex measured at 415 nm. The fourth method involves the formation of a yellow complex peaking at 361 nm upon the reaction of the drug with iodine in chloroform. Experimental conditions affecting the color development were studied and optimized. Stoichiometry of the reactions was determined. The proposed spectrophotometric procedures were effectively validated with respect to linearity, ranges, precision, accuracy, specificity, robustness, detection and quantification limits. Calibration curves of the formed color products with p-CA, DC, PA and iodine showed good linear relationships over the concentration ranges 24-144, 40-200, 2-20 and 1-8 μg/mL respectively. The proposed methods were successfully applied to the assay of sodium valproate in tablets and oral solution dosage forms with good accuracy and precision. Assay results were statistically compared to a reference pharmacopoeial HPLC method where no significant differences were observed between the proposed methods and reference method.

  13. A Brownian dynamics program for the simulation of linear and circular DNA and other wormlike chain polyelectrolytes.

    PubMed Central

    Klenin, K; Merlitz, H; Langowski, J

    1998-01-01

    For the interpretation of solution structural and dynamic data of linear and circular DNA molecules in the kb range, and for the prediction of the effect of local structural changes on the global conformation of such DNAs, we have developed an efficient and easy way to set up a program based on a second-order explicit Brownian dynamics algorithm. The DNA is modeled by a chain of rigid segments interacting through harmonic spring potentials for bending, torsion, and stretching. The electrostatics are handled using precalculated energy tables for the interactions between DNA segments as a function of relative orientation and distance. Hydrodynamic interactions are treated using the Rotne-Prager tensor. While maintaining acceptable precision, the simulation can be accelerated by recalculating this tensor only once in a certain number of steps. PMID:9533691

  14. Fiber optics frequency comb enabled linear optical sampling with operation wavelength range extension.

    PubMed

    Liao, Ruolin; Wu, Zhichao; Fu, Songnian; Zhu, Shengnan; Yu, Zhe; Tang, Ming; Liu, Deming

    2018-02-01

    Although the linear optical sampling (LOS) technique is powerful enough to characterize various advanced modulation formats with high symbol rates, the central wavelength of a pulsed local oscillator (LO) needs to be carefully set according to that of the signal under test, due to the coherent mixing operation. Here, we experimentally demonstrate wideband LOS enabled by a fiber optics frequency comb (FOFC). Meanwhile, when the broadband FOFC acts as the pulsed LO, we propose a scheme to mitigate the enhanced sampling error arising in the non-ideal response of a balanced photodetector. Finally, precise characterizations of arbitrary 128 Gbps PDM-QPSK wavelength channels from 1550 to 1570 nm are successfully achieved, when a 101.3 MHz frequency spaced comb with a 3 dB spectral power ripple of 20 nm is used.

  15. A method for fast determination of psoralens in oral solutions of phytomedicines using liquid chromatography.

    PubMed

    Pires, Adriana Elias; Honda, Neli Kiko; Cardoso, Cláudia Andréa Lima

    2004-10-29

    A method for sample preparation and analysis by high performance liquid chromatography with UV detection (HPLC-UV) has been developed for routine analysis of psoralen and bergapten, photosensitizing compounds, in oral solutions of phytomedicines employed in Brazil for some illnesses. The linearity, accuracy, the inter- and intra-day precision of the procedure were evaluated. Calibration curves for psoralen and bergapten were linear in the range of 1.0-600.0 microg ml(-1) and 1.0-400.0 microg ml(-1) respectively. The recoveries of the psoralens in the oral solutions analysed were 94.43-99.97%. The percentage coefficient of variation (CV) of the quantitative analysis of the psoralens in the products analysis was within 5%. In inter-equipment study was employed gas chromatography-flame ionization (CG-FID) detection.

  16. An update on the development of a line-focus refractive concentrator array

    NASA Technical Reports Server (NTRS)

    Piszczor, Michael F.; Oneill, Mark J.; Fraas, Lewis M.

    1994-01-01

    Concentrator arrays offer a number of generic benefits for space (i.e. high array efficiency, protection from space radiation effects, minimized plasma interactions, etc.). The line-focus refractive concept, however, also offers two very important advantages: (1) relaxation of precise array tracking requirements to only a single axis and (2) low-cost mass production of the lens material. The linear refractive concentrator can be designed to provide an essentially flat response over a wide range of longitudinal errors for satellites having only single-axis tracking capability. New panel designs emphasize light weight, high stiffness, storability, and ease of manufacturing and assembly. This paper addresses the current status of the concentrator program with special emphasis on the design implications, and flexibility, of using a linear refractive concentrator lens as well as details recent fabrication of prototype hardware.

  17. An Update on the Development of a Line-Focus Refractive Concentrator Array

    NASA Technical Reports Server (NTRS)

    Piszczor, Michael F.; ONeill, Mark J.; Fraas, Lewis M.

    1994-01-01

    Concentrator arrays offer a number of generic benefits for space (i.e. high array efficiency, protection from space radiation effects, minimized plasma interactions, etc.). The line-focus refractive concentrator concept, however, also offers two very important advantages: (1) relaxation of precise array tracking requirements to only a single axis and (2) low-cost mass production of the lens material. The linear refractive concentrator can be designed to provide an essentially flat response over a wide range of longitudinal errors for satellites having only single-axis tracking capability. New panel designs emphasize light weight, high stiffness, stowability and ease of manufacturing and assembly. This paper will address the current status of the concentrator program with special emphasis on the design implications, and flexibility, of using a linear refractive concentrator lens as well as detail the recent fabrication of prototype hardware.

  18. High performance liquid chromatographic assay for the quantitation of total glutathione in plasma

    NASA Technical Reports Server (NTRS)

    Abukhalaf, Imad K.; Silvestrov, Natalia A.; Menter, Julian M.; von Deutsch, Daniel A.; Bayorh, Mohamed A.; Socci, Robin R.; Ganafa, Agaba A.

    2002-01-01

    A simple and widely used homocysteine HPLC procedure was applied for the HPLC identification and quantitation of glutathione in plasma. The method, which utilizes SBDF as a derivatizing agent utilizes only 50 microl of sample volume. Linear quantitative response curve was generated for glutathione over a concentration range of 0.3125-62.50 micromol/l. Linear regression analysis of the standard curve exhibited correlation coefficient of 0.999. Limit of detection (LOD) and limit of quantitation (LOQ) values were 5.0 and 15 pmol, respectively. Glutathione recovery using this method was nearly complete (above 96%). Intra-assay and inter-assay precision studies reflected a high level of reliability and reproducibility of the method. The applicability of the method for the quantitation of glutathione was demonstrated successfully using human and rat plasma samples.

  19. Nearby Dwarf Stars: Duplicity, Binarity, and Masses

    NASA Astrophysics Data System (ADS)

    Mason, Brian D.; Hartkopf, William I.; Henry, Todd J.; Jao, Wei-Chun; Subasavage, John; Riedel, Adric; Winters, Jennifer

    2010-02-01

    Double stars have proven to be both a blessing and a curse for astronomers since their discovery over two centuries ago. They remain the only reliable source of masses, the most fundamental parameter defining stars. On the other hand, their sobriquet ``vermin of the sky'' is well-earned, due to the complications they present to both observers and theoreticians. These range from non-linear proper motions to stray light in detectors, to confusion in pointing of instruments due to non-symmetric point spread functions, to angular momentum conservation in multiple stars which results in binaries closer than allowed by evolution of two single stars. This proposal is primarily focused on targets where precise astrophysical information is sorely lacking: white dwarfs, red dwarfs, and subdwarfs. The proposed work will refine current statistics regarding duplicity (chance alignments of nearby point sources) and binarity (actual physical relationships), and improve the precisions and accuracies of stellar masses. Several targets support Riedel's and Winters' theses.

  20. Nearby Dwarf Stars: Duplicity, Binarity, and Masses

    NASA Astrophysics Data System (ADS)

    Mason, Brian D.; Hartkopf, William I.; Henry, Todd J.; Jao, Wei-Chun; Subasavage, John; Riedel, Adric; Winters, Jennifer

    2009-08-01

    Double stars have proven to be both a blessing and a curse for astronomers since their discovery over two centuries ago. They remain the only reliable source of masses, the most fundamental parameter defining stars. On the other hand, their sobriquet ``vermin of the sky'' is well-earned, due to the complications they present to both observers and theoreticians. These range from non-linear proper motions to stray light in detectors, to confusion in pointing of instruments due to non-symmetric point spread functions, to angular momentum conservation in multiple stars which results in binaries closer than allowed by evolution of two single stars. This proposal is primarily focused on targets where precise astrophysical information is sorely lacking: white dwarfs, red dwarfs, and subdwarfs. The proposed work will refine current statistics regarding duplicity (chance alignments of nearby point sources) and binarity (actual physical relationships), and improve the precisions and accuracies of stellar masses. Several targets support Riedel's and Winters' theses.

  1. Exploration and extension of an improved Riemann track fitting algorithm

    NASA Astrophysics Data System (ADS)

    Strandlie, A.; Frühwirth, R.

    2017-09-01

    Recently, a new Riemann track fit which operates on translated and scaled measurements has been proposed. This study shows that the new Riemann fit is virtually as precise as popular approaches such as the Kalman filter or an iterative non-linear track fitting procedure, and significantly more precise than other, non-iterative circular track fitting approaches over a large range of measurement uncertainties. The fit is then extended in two directions: first, the measurements are allowed to lie on plane sensors of arbitrary orientation; second, the full error propagation from the measurements to the estimated circle parameters is computed. The covariance matrix of the estimated track parameters can therefore be computed without recourse to asymptotic properties, and is consequently valid for any number of observation. It does, however, assume normally distributed measurement errors. The calculations are validated on a simulated track sample and show excellent agreement with the theoretical expectations.

  2. Iterative matrix algorithm for high precision temperature and force decoupling in multi-parameter FBG sensing.

    PubMed

    Hopf, Barbara; Dutz, Franz J; Bosselmann, Thomas; Willsch, Michael; Koch, Alexander W; Roths, Johannes

    2018-04-30

    A new iterative matrix algorithm has been applied to improve the precision of temperature and force decoupling in multi-parameter FBG sensing. For the first time, this evaluation technique allows the integration of nonlinearities in the sensor's temperature characteristic and the temperature dependence of the sensor's force sensitivity. Applied to a sensor cable consisting of two FBGs in fibers with 80 µm and 125 µm cladding diameter installed in a 7 m-long coiled PEEK capillary, this technique significantly reduced the uncertainties in friction-compensated temperature measurements. In the presence of high friction-induced forces of up to 1.6 N the uncertainties in temperature evaluation were reduced from several degrees Celsius if using a standard linear matrix approach to less than 0.5°C if using the iterative matrix approach in an extended temperature range between -35°C and 125°C.

  3. High-performance liquid chromatography-electrospray ionization mass spectrometry determination of sodium ferulate in human plasma.

    PubMed

    Yang, Cheng; Tian, Yuan; Zhang, Zunjian; Xu, Fengguo; Chen, Yun

    2007-02-19

    A selective and sensitive high-performance liquid chromatography-electrospray ionization mass spectrometry method has been developed for the determination of sodium ferulate in human plasma. The sample preparation was a liquid-liquid extraction and chromatographic separation was achieved with an Agilent ZORBAX SB-C(18) (3.5 microm, 100 mm x 3.0 mm) column, using a mobile phase of methanol-0.05% acetic acid 40:60 (v/v). Standard curves were linear (r(2)=0.9982) over the concentration range of 0.007-4.63 nM/ml and had acceptable accuracy and precision. The within- and between-batch precisions were within 12% relative standard deviation. The lower limit of quantification (LLOQ) was 0.007 nM/ml. The validated HPLC-ESI-MS method has been used successfully to study sodium ferulate pharmacokinetics, bioavailability and bioequivalence in 20 healthy volunteers.

  4. Analytical performances of the Diazyme ADA assay on the Cobas® 6000 system.

    PubMed

    Delacour, Hervé; Sauvanet, Christophe; Ceppa, Franck; Burnat, Pascal

    2010-12-01

    To evaluate the analytical performance of the Diazyme ADA assay on the Cobas® 6000 system for pleural fluid samples analysis. Imprecision, linearity, calibration curve stability, interference, and correlation studies were completed. The Diazyme ADA assay demonstrated excellent precision (CV<4%) over the analytical measurement range (0.5-117 U/L). Bilirubin above 50 μmol/L and haemoglobin above 177 μmol/L interfered with the test, inducing a negative and a positive interference respectively. The Diazyme ADA assay correlated well with the Giusti method (r(2)=0.93) but exhibited a negative bias (~ -30%). The Diazyme ADA assay on the Cobas® 6000 system represents a rapid, accurate, precise and reliable method for determination of ADA activity in pleural fluid samples. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. Development and validation of new spectrophotometric ratio H-point standard addition method and application to gastrointestinal acting drugs mixtures.

    PubMed

    Yehia, Ali M

    2013-05-15

    New, simple, specific, accurate and precise spectrophotometric technique utilizing ratio spectra is developed for simultaneous determination of two different binary mixtures. The developed ratio H-point standard addition method (RHPSAM) was managed successfully to resolve the spectral overlap in itopride hydrochloride (ITO) and pantoprazole sodium (PAN) binary mixture, as well as, mosapride citrate (MOS) and PAN binary mixture. The theoretical background and advantages of the newly proposed method are presented. The calibration curves are linear over the concentration range of 5-60 μg/mL, 5-40 μg/mL and 4-24 μg/mL for ITO, MOS and PAN, respectively. Specificity of the method was investigated and relative standard deviations were less than 1.5. The accuracy, precision and repeatability were also investigated for the proposed method according to ICH guidelines. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Development and validation of new spectrophotometric ratio H-point standard addition method and application to gastrointestinal acting drugs mixtures

    NASA Astrophysics Data System (ADS)

    Yehia, Ali M.

    2013-05-01

    New, simple, specific, accurate and precise spectrophotometric technique utilizing ratio spectra is developed for simultaneous determination of two different binary mixtures. The developed ratio H-point standard addition method (RHPSAM) was managed successfully to resolve the spectral overlap in itopride hydrochloride (ITO) and pantoprazole sodium (PAN) binary mixture, as well as, mosapride citrate (MOS) and PAN binary mixture. The theoretical background and advantages of the newly proposed method are presented. The calibration curves are linear over the concentration range of 5-60 μg/mL, 5-40 μg/mL and 4-24 μg/mL for ITO, MOS and PAN, respectively. Specificity of the method was investigated and relative standard deviations were less than 1.5. The accuracy, precision and repeatability were also investigated for the proposed method according to ICH guidelines.

  7. Novel spectrophotometric determination of flumethasone pivalate and clioquinol in their binary mixture and pharmaceutical formulation.

    PubMed

    Abdel-Aleem, Eglal A; Hegazy, Maha A; Sayed, Nour W; Abdelkawy, M; Abdelfatah, Rehab M

    2015-02-05

    This work is concerned with development and validation of three simple, specific, accurate and precise spectrophotometric methods for determination of flumethasone pivalate (FP) and clioquinol (CL) in their binary mixture and ear drops. Method A is a ratio subtraction spectrophotometric one (RSM). Method B is a ratio difference spectrophotometric one (RDSM), while method C is a mean center spectrophotometric one (MCR). The calibration curves are linear over the concentration range of 3-45 μg/mL for FP, and 2-25 μg/mL for CL. The specificity of the developed methods was assessed by analyzing different laboratory prepared mixtures of the FP and CL. The three methods were validated as per ICH guidelines; accuracy, precision and repeatability are found to be within the acceptable limits. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Three different spectrophotometric methods manipulating ratio spectra for determination of binary mixture of Amlodipine and Atorvastatin

    NASA Astrophysics Data System (ADS)

    Darwish, Hany W.; Hassan, Said A.; Salem, Maissa Y.; El-Zeiny, Badr A.

    2011-12-01

    Three simple, specific, accurate and precise spectrophotometric methods manipulating ratio spectra are developed for the simultaneous determination of Amlodipine besylate (AM) and Atorvastatin calcium (AT) in tablet dosage forms. The first method is first derivative of the ratio spectra ( 1DD), the second is ratio subtraction and the third is the method of mean centering of ratio spectra. The calibration curve is linear over the concentration range of 3-40 and 8-32 μg/ml for AM and AT, respectively. These methods are tested by analyzing synthetic mixtures of the above drugs and they are applied to commercial pharmaceutical preparation of the subjected drugs. Standard deviation is <1.5 in the assay of raw materials and tablets. Methods are validated as per ICH guidelines and accuracy, precision, repeatability and robustness are found to be within the acceptable limit.

  9. Three different methods for determination of binary mixture of Amlodipine and Atorvastatin using dual wavelength spectrophotometry

    NASA Astrophysics Data System (ADS)

    Darwish, Hany W.; Hassan, Said A.; Salem, Maissa Y.; El-Zeany, Badr A.

    2013-03-01

    Three simple, specific, accurate and precise spectrophotometric methods depending on the proper selection of two wavelengths are developed for the simultaneous determination of Amlodipine besylate (AML) and Atorvastatin calcium (ATV) in tablet dosage forms. The first method is the new Ratio Difference method, the second method is the Bivariate method and the third one is the Absorbance Ratio method. The calibration curve is linear over the concentration range of 4-40 and 8-32 μg/mL for AML and ATV, respectively. These methods are tested by analyzing synthetic mixtures of the above drugs and they are applied to commercial pharmaceutical preparation of the subjected drugs. Methods are validated according to the ICH guidelines and accuracy, precision, repeatability and robustness are found to be within the acceptable limit. The mathematical explanation of the procedures is illustrated.

  10. Rapid and sensitive analysis of multiple bioactive constituents in tripterygium glycosides tablets using liquid chromatography coupled with time-of-flight mass spectrometry.

    PubMed

    Su, Meng-xiang; Zhou, Wen-di; Lan, Juan; Di, Bin; Hang, Tai-jun

    2015-03-01

    A simultaneous determination method based on liquid chromatography coupled with time-of-flight mass spectrometry was developed for the analysis of 11 bioactive constituents in tripterygium glycosides tablets, an immune and inflammatory prescription used in China. The analysis was fully optimized on a 1.8 μm particle size C18 column with linear gradient elution, permitting good separation of the 11 analytes and two internal standards in 21 min. The quantitation of each target constituent was carried out using the narrow window extracted ion chromatograms with a ±l0 ppm extraction window, yielding good linearity (r(2) > 0.996) with a linear range of 10-1000 ng/mL. The limits of quantitation were low ranging from 0.25 to 5.02 ng/mL for the 11 analytes, and the precisions and repeatability were better than 1.6 and 5.3%, respectively. The acceptable recoveries obtained were in the range of 93.4-107.4%. This proposed method was successfully applied to quantify the 11 bioactive constituents in commercial samples produced by nine pharmaceutical manufacturers to profile the quality of these preparations. The overall results demonstrate that the contents of the 11 bioactive constituents in different samples were in great diversity, therefore, the quality, clinical safety, and efficacy of this drug needs further research and evaluation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Elastic and mechanical softening in boron-doped diamond

    PubMed Central

    Liu, Xiaobing; Chang, Yun-Yuan; Tkachev, Sergey N.; Bina, Craig R.; Jacobsen, Steven D.

    2017-01-01

    Alternative approaches to evaluating the hardness and elastic properties of materials exhibiting physical properties comparable to pure diamond have recently become necessary. The classic linear relationship between shear modulus (G) and Vickers hardness (HV), along with more recent non-linear formulations based on Pugh’s modulus extending into the superhard region (HV > 40 GPa) have guided synthesis and identification of novel superabrasives. These schemes rely on accurately quantifying HV of diamond-like materials approaching or potentially exceeding the hardness of the diamond indenter, leading to debate about methodology and the very definition of hardness. Elasticity measurements on such materials are equally challenging. Here we used a high-precision, GHz-ultrasonic interferometer in conjunction with a newly developed optical contact micrometer and 3D optical microscopy of indentations to evaluate elasticity-hardness relations in the ultrahard range (HV > 80 GPa) by examining single-crystal boron-doped diamond (BDD) with boron contents ranging from 50–3000 ppm. We observe a drastic elastic-mechanical softening in highly doped BDD relative to the trends observed for superhard materials, providing insight into elasticity-hardness relations for ultrahard materials. PMID:28233808

  12. Micro-fabrication of a novel linear actuator

    NASA Astrophysics Data System (ADS)

    Jiang, Shuidong; Liu, Lei; Hou, Yangqing; Fang, Houfei

    2017-04-01

    The novel linear actuator is researched with light weight, small volume, low power consumption, fast response and relatively large displacement output. It can be used for the net surface control of large deployable mesh antennas, the tension precise adjustment of the controlled cable in the tension and tensile truss structure and many other applications. The structure and the geometry parameters are designed and analysed by finite element method in multi-physics coupling. Meantime, the relationship between input voltage and displacement output is computed, and the strength check is completed according to the stress distribution. Carbon fiber reinforced composite (CFRC), glass fiber reinforced composited (GFRC), and Lead Zirconium Titanate (PZT) materials are used to fabricate the actuator by using laser etching and others MEMS process. The displacement output is measured by the laser displacement sensor device at the input voltage range of DC0-180V. The response time is obtained by oscilloscope at the arbitrarily voltage in the above range. The nominal force output is measured by the PTR-1101 mechanics setup. Finally, the computed and test results are compared and analysed.

  13. Elastic and mechanical softening in boron-doped diamond

    NASA Astrophysics Data System (ADS)

    Liu, Xiaobing; Chang, Yun-Yuan; Tkachev, Sergey N.; Bina, Craig R.; Jacobsen, Steven D.

    2017-02-01

    Alternative approaches to evaluating the hardness and elastic properties of materials exhibiting physical properties comparable to pure diamond have recently become necessary. The classic linear relationship between shear modulus (G) and Vickers hardness (HV), along with more recent non-linear formulations based on Pugh’s modulus extending into the superhard region (HV > 40 GPa) have guided synthesis and identification of novel superabrasives. These schemes rely on accurately quantifying HV of diamond-like materials approaching or potentially exceeding the hardness of the diamond indenter, leading to debate about methodology and the very definition of hardness. Elasticity measurements on such materials are equally challenging. Here we used a high-precision, GHz-ultrasonic interferometer in conjunction with a newly developed optical contact micrometer and 3D optical microscopy of indentations to evaluate elasticity-hardness relations in the ultrahard range (HV > 80 GPa) by examining single-crystal boron-doped diamond (BDD) with boron contents ranging from 50-3000 ppm. We observe a drastic elastic-mechanical softening in highly doped BDD relative to the trends observed for superhard materials, providing insight into elasticity-hardness relations for ultrahard materials.

  14. voom: precision weights unlock linear model analysis tools for RNA-seq read counts

    PubMed Central

    2014-01-01

    New normal linear modeling strategies are presented for analyzing read counts from RNA-seq experiments. The voom method estimates the mean-variance relationship of the log-counts, generates a precision weight for each observation and enters these into the limma empirical Bayes analysis pipeline. This opens access for RNA-seq analysts to a large body of methodology developed for microarrays. Simulation studies show that voom performs as well or better than count-based RNA-seq methods even when the data are generated according to the assumptions of the earlier methods. Two case studies illustrate the use of linear modeling and gene set testing methods. PMID:24485249

  15. voom: Precision weights unlock linear model analysis tools for RNA-seq read counts.

    PubMed

    Law, Charity W; Chen, Yunshun; Shi, Wei; Smyth, Gordon K

    2014-02-03

    New normal linear modeling strategies are presented for analyzing read counts from RNA-seq experiments. The voom method estimates the mean-variance relationship of the log-counts, generates a precision weight for each observation and enters these into the limma empirical Bayes analysis pipeline. This opens access for RNA-seq analysts to a large body of methodology developed for microarrays. Simulation studies show that voom performs as well or better than count-based RNA-seq methods even when the data are generated according to the assumptions of the earlier methods. Two case studies illustrate the use of linear modeling and gene set testing methods.

  16. The research of radar target tracking observed information linear filter method

    NASA Astrophysics Data System (ADS)

    Chen, Zheng; Zhao, Xuanzhi; Zhang, Wen

    2018-05-01

    Aiming at the problems of low precision or even precision divergent is caused by nonlinear observation equation in radar target tracking, a new filtering algorithm is proposed in this paper. In this algorithm, local linearization is carried out on the observed data of the distance and angle respectively. Then the kalman filter is performed on the linearized data. After getting filtered data, a mapping operation will provide the posteriori estimation of target state. A large number of simulation results show that this algorithm can solve above problems effectively, and performance is better than the traditional filtering algorithm for nonlinear dynamic systems.

  17. Linear signal noise summer accurately determines and controls S/N ratio

    NASA Technical Reports Server (NTRS)

    Sundry, J. L.

    1966-01-01

    Linear signal noise summer precisely controls the relative power levels of signal and noise, and mixes them linearly in accurately known ratios. The S/N ratio accuracy and stability are greatly improved by this technique and are attained simultaneously.

  18. Linear Covariance Analysis for a Lunar Lander

    NASA Technical Reports Server (NTRS)

    Jang, Jiann-Woei; Bhatt, Sagar; Fritz, Matthew; Woffinden, David; May, Darryl; Braden, Ellen; Hannan, Michael

    2017-01-01

    A next-generation lunar lander Guidance, Navigation, and Control (GNC) system, which includes a state-of-the-art optical sensor suite, is proposed in a concept design cycle. The design goal is to allow the lander to softly land within the prescribed landing precision. The achievement of this precision landing requirement depends on proper selection of the sensor suite. In this paper, a robust sensor selection procedure is demonstrated using a Linear Covariance (LinCov) analysis tool developed by Draper.

  19. Milrinone therapeutic drug monitoring in a pediatric population: Development and validation of a quantitative liquid chromatography-tandem mass spectrometry method.

    PubMed

    Raizman, Joshua E; Taylor, Katherine; Parshuram, Christopher; Colantonio, David A

    2017-05-01

    Milrinone is a potent selective phosphodiesterase type III inhibitor which stimulates myocardial function and improves myocardial relaxation. Although therapeutic monitoring is crucial to maintain therapeutic outcome, little data is available. A proof-of-principle study has been initiated in our institution to evaluate the clinical impact of optimizing milrinone dosing through therapeutic drug monitoring (TDM) in children following cardiac surgery. We developed a robust LC-MS/MS method to quantify milrinone in serum from pediatric patients in real-time. A liquid-liquid extraction procedure was used to prepare samples for analysis prior to measurement by LC-MS/MS. Performance characteristics, such as linearity, limit of quantitation (LOQ) and precision, were assessed. Patient samples were acquired post-surgery and analyzed to determine the concentration-time profile of the drug as well as to track turn-around-times. Within day precision was <8.3% across 3 levels of QC. Between-day precision was <12%. The method was linear from 50 to 800μg/l; the lower limit of quantification was 22μg/l. Comparison with another LC-MS/MS method showed good agreement. Using this simplified method, turnaround times within 3-6h were achievable, and patient drug profiles demonstrated that some milrinone levels were either sub-therapeutic or in the toxic range, highlighting the importance for milrinone TDM. This simplified and quick method proved to be analytically robust and able to provide therapeutic monitoring of milrinone in real-time in patients post-cardiac surgery. Copyright © 2017. Published by Elsevier B.V.

  20. Fractal geometry of music.

    PubMed Central

    Hsü, K J; Hsü, A J

    1990-01-01

    Music critics have compared Bach's music to the precision of mathematics. What "mathematics" and what "precision" are the questions for a curious scientist. The purpose of this short note is to suggest that the mathematics is, at least in part, Mandelbrot's fractal geometry and the precision is the deviation from a log-log linear plot. PMID:11607061

  1. Simultaneous determination of trace migration of phthalate esters in honey and royal jelly by GC-MS.

    PubMed

    Zhou, Jinhui; Qi, Yitao; Wu, Hongmei; Diao, Qingyun; Tian, Feifei; Li, Yi

    2014-03-01

    A simple, rapid, and reliable liquid-liquid extraction coupled to GC-MS method was developed and validated for the quantification of 22 phthalate esters (PAEs) in honey and royal jelly. Instrument parameters for GC-MS were tested to obtain the satisfactory separation between 22 PAEs with high sensitivity. The extraction procedure was optimized in order to achieve the best recovery. The following criteria were used to validate the developed method: linearity, LOD, lower LOQ, precision, accuracy, matrix effect and carry-over. Correlation coefficients were >0.999 by applying the linear regression model based on the least-squares method with a weighting factor (1/x). The intra- and interday precision were within 12.7% in terms of RSD, and the accuracy was within -11.8% in terms of relative error. The mean extraction recoveries ranged between 80.1 and 110.9% for honey and royal jelly. No significant matrix effect and carry-over for PAEs were observed for the analysis of honey and royal jelly samples. A total of 20 real samples were analyzed for a mini-survey using the developed method. Seven PAEs in honey samples and five PAEs in royal jelly samples were found, indicating potential contamination with several PAEs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. LC-MS/MS methods for sulfadimethoxine and ormetoprim analysis in feed and fish fillet and a leaching study for feed after alternative procedures for the incorporation of drugs.

    PubMed

    Fais, Ana Paula; Franco, Rodolfo Scarpino Barboza; da Silva, Agnaldo Fernando Baldo; de Freitas, Osvaldo; Paschoal, Jonas Augusto Rizzato

    2017-04-01

    This paper describes the method development for sulfadimethoxine (SDM) and ormetoprim (OMP) quantitation in fish feed and fish fillet employing LC-MS/MS. In order to assess the reliability of the analytical method, valuation was undertaken as recommended by guidelines proposed by the Brazilian Ministry of Agriculture. The calibration curve for the quantification of both drugs in feed showed adequate linearity (r > 0.99), precision (CV < 12%) and trueness ranging from 97% to 100%. The method for the determination of SDM and OMP residues in fish fillet involved a simple sample preparation procedure that had adequate linearity (r > 0.99), precision (CV < 16%) and trueness around 100%, with CCα < 100.2 ng g - 1 and CCβ < 100.4 ng g - 1 . With a goal of avoiding the risk of drug leaching from feed into the aquatic environment during fish medication via the oral route, different procedures for drug incorporation into feed were evaluated. Coating feed pellets with ethyl cellulose polymer containing the drug showed promising results. In this case, medicated feed released drugs to water at a level below 6% when the medicated feed stayed in the water for up to 15 min.

  3. Development and validation of a reversed-phase HPLC method for simultaneous estimation of ambroxol hydrochloride and azithromycin in tablet dosage form.

    PubMed

    Shaikh, K A; Patil, S D; Devkhile, A B

    2008-12-15

    A simple, precise and accurate reversed-phase liquid chromatographic method has been developed for the simultaneous estimation of ambroxol hydrochloride and azithromycin in tablet formulations. The chromatographic separation was achieved on a Xterra RP18 (250 mm x 4.6 mm, 5 microm) analytical column. A Mixture of acetonitrile-dipotassium phosphate (30 mM) (50:50, v/v) (pH 9.0) was used as the mobile phase, at a flow rate of 1.7 ml/min and detector wavelength at 215 nm. The retention time of ambroxol and azithromycin was found to be 5.0 and 11.5 min, respectively. The validation of the proposed method was carried out for specificity, linearity, accuracy, precision, limit of detection, limit of quantitation and robustness. The linear dynamic ranges were from 30-180 to 250-1500 microg/ml for ambroxol hydrochloride and azithromycin, respectively. The percentage recovery obtained for ambroxol hydrochloride and azithromycin were 99.40 and 99.90%, respectively. Limit of detection and quantification for azithromycin were 0.8 and 2.3 microg/ml, for ambroxol hydrochloride 0.004 and 0.01 microg/ml, respectively. The developed method can be used for routine quality control analysis of titled drugs in combination in tablet formulation.

  4. N-nitrosamines as "special case" leachables in a metered dose inhaler drug product.

    PubMed

    Norwood, Daniel L; Mullis, James O; Feinberg, Thomas N; Davis, Letha K

    2009-01-01

    N-nitrosamines are chemical entities, some of which are considered to be possible human carcinogens, which can be found at trace levels in some types of foods, tobacco smoke, certain cosmetics, and certain types of rubber. N-nitrosamines are of regulatory concern as leachables in inhalation drug products, particularly metered dose inhalers, which incorporate rubber seals into their container closure systems. The United States Food and Drug Administration considers N-nitrosamines (along with polycyclic aromatic hydrocarbons and 2-mercaptobenzothiazole) to be "special case" leachables in inhalation drug products, meaning that there are no recognized safety or analytical thresholds and these compounds must therefore be identified and quantitated at the lowest practical level. This report presents the development of a quantitative analytical method for target volatile N-nitrosamines in a metered dose inhaler drug product, Atrovent HFA. The method incorporates a target analyte recovery procedure from the drug product matrix with analysis by gas chromatography/thermal energy analysis detection. The capability of the method was investigated with respect to specificity, linearity/range, accuracy (linearity of recovery), precision (repeatability, intermediate precision), limits of quantitation, standard/sample stability, and system suitability. Sample analyses showed that Atrovent HFA contains no target N-nitrosamines at the trace level of 1 ng/canister.

  5. Validation and Uncertainty Estimation of an Ecofriendly and Stability-Indicating HPLC Method for Determination of Diltiazem in Pharmaceutical Preparations

    PubMed Central

    Sadeghi, Fahimeh; Navidpour, Latifeh; Bayat, Sima; Afshar, Minoo

    2013-01-01

    A green, simple, and stability-indicating RP-HPLC method was developed for the determination of diltiazem in topical preparations. The separation was based on a C18 analytical column using a mobile phase consisted of ethanol: phosphoric acid solution (pH = 2.5) (35 : 65, v/v). Column temperature was set at 50°C and quantitation was achieved with UV detection at 240 nm. In forced degradation studies, the drug was subjected to oxidation, hydrolysis, photolysis, and heat. The method was validated for specificity, selectivity, linearity, precision, accuracy, and robustness. The applied procedure was found to be linear in diltiazem concentration range of 0.5–50 μg/mL (r 2 = 0.9996). Precision was evaluated by replicate analysis in which % relative standard deviation (RSD) values for areas were found below 2.0. The recoveries obtained (99.25%–101.66%) ensured the accuracy of the developed method. The degradation products as well as the pharmaceutical excipients were well resolved from the pure drug. The expanded uncertainty (5.63%) of the method was also estimated from method validation data. Accordingly, the proposed validated and sustainable procedure was proved to be suitable for routine analyzing and stability studies of diltiazem in pharmaceutical preparations. PMID:24163778

  6. Complement dependent cytotoxicity (CDC) activity of a humanized anti Lewis-Y antibody: FACS-based assay versus the 'classical' radioactive method -- qualification, comparison and application of the FACS-based approach.

    PubMed

    Nechansky, A; Szolar, O H J; Siegl, P; Zinoecker, I; Halanek, N; Wiederkum, S; Kircheis, R

    2009-05-01

    The fully humanized Lewis-Y carbohydrate specific monoclonal antibody (mAb) IGN311 is currently tested in a passive immunotherapy approach in a clinical phase I trail and therefore regulatory requirements demand qualified assays for product analysis. To demonstrate the functionality of its Fc-region, the capacity of IGN311 to mediate complement dependent cytotoxicity (CDC) against human breast cancer cells was evaluated. The "classical" radioactive method using chromium-51 and a FACS-based assay were established and qualified according to ICH guidelines. Parameters evaluated were specificity, response function, bias, repeatability (intra-day precision), intermediate precision (operator-time different), and linearity (assay range). In the course of a fully nested design, a four-parameter logistic equation was identified as appropriate calibration model for both methods. For the radioactive assay, the bias ranged from -6.1% to -3.6%. The intermediate precision for future means of duplicate measurements revealed values from 12.5% to 15.9% and the total error (beta-expectation tolerance interval) of the method was found to be <40%. For the FACS-based assay, the bias ranged from -8.3% to 0.6% and the intermediate precision for future means of duplicate measurements revealed values from 4.2% to 8.0%. The total error of the method was found to be <25%. The presented data demonstrate that the FACS-based CDC is more accurate than the radioactive assay. Also, the elimination of radioactivity and the 'real-time' counting of apoptotic cells further justifies the implementation of this method which was subsequently applied for testing the influence of storage at 4 degrees C and 25 degrees C ('stability testing') on the potency of IGN311 drug product. The obtained results demonstrate that the qualified functional assay represents a stability indicating test method.

  7. Positioner with long travel in two dimensions

    DOEpatents

    Trumper, David L.; Williams, Mark E.

    1997-12-23

    A precision positioning system is provided which provides long travel in two of the linear dimensions, while using non-contact bearings for both a first subassembly which provides long travel in one of the linear dimension and a second subassembly which provides long travel in the second linear dimension. The first or upper subassembly is preferably a magnetic subassembly which, in addition to providing long travel, also compensates or positions in three rotary dimensions and in the third linear dimension. The second subassembly is preferably either an air bearing or magnetic subassembly and is normally used only to provide long travel. Angled surfaces may be provided for magnetic bearings and capacitive or other gap sensing probes may be mounted to the stage and ground flush with the bearing actuators to provide more precise gap measurements.

  8. Method of high precision interval measurement in pulse laser ranging system

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Lv, Xin-yuan; Mao, Jin-jin; Liu, Wei; Yang, Dong

    2013-09-01

    Laser ranging is suitable for laser system, for it has the advantage of high measuring precision, fast measuring speed,no cooperative targets and strong resistance to electromagnetic interference,the measuremen of laser ranging is the key paremeters affecting the performance of the whole system.The precision of the pulsed laser ranging system was decided by the precision of the time interval measurement, the principle structure of laser ranging system was introduced, and a method of high precision time interval measurement in pulse laser ranging system was established in this paper.Based on the analysis of the factors which affected the precision of range measure,the pulse rising edges discriminator was adopted to produce timing mark for the start-stop time discrimination,and the TDC-GP2 high precision interval measurement system based on TMS320F2812 DSP was designed to improve the measurement precision.Experimental results indicate that the time interval measurement method in this paper can obtain higher range accuracy. Compared with the traditional time interval measurement system,the method simplifies the system design and reduce the influence of bad weather conditions,furthermore,it satisfies the requirements of low costs and miniaturization.

  9. Verification of spectrophotometric method for nitrate analysis in water samples

    NASA Astrophysics Data System (ADS)

    Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu

    2017-12-01

    The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.

  10. Intensity Modulation Techniques for Continuous-Wave Lidar for Column CO2 Measurements

    NASA Astrophysics Data System (ADS)

    Campbell, J. F.; Lin, B.; Obland, M. D.; Kooi, S. A.; Fan, T. F.; Meadows, B.; Browell, E. V.; Erxleben, W. H.; McGregor, D.; Dobler, J. T.; Pal, S.; O'Dell, C.

    2017-12-01

    Global and regional atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission and the Atmospheric Carbon and Transport (ACT) - America project are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity-Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space and airborne platforms to meet the ASCENDS and ACT-America science measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) and Linear Swept Frequency modulations to uniquely discriminate surface lidar returns from intermediate aerosol and cloud returns. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that take advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques and provides very high (at sub-meter level) range resolution. We compare BPSK to linear swept frequency and introduce a new technique to eliminate sidelobes in situations from linear swept frequency where the SNR is high with results that rival BPSK. We also investigate the effects of non-linear modulators, which can in some circumstances degrade the orthogonality of the waveforms, and show how to avoid this. These techniques are used in a new data processing architecture written in the C language to support the ASCENDS CarbonHawk Experiment Simulator (ACES) and ACT-America programs.

  11. Precision measurements and computations of transition energies in rotationally cold triatomic hydrogen ions up to the midvisible spectral range.

    PubMed

    Pavanello, Michele; Adamowicz, Ludwik; Alijah, Alexander; Zobov, Nikolai F; Mizus, Irina I; Polyansky, Oleg L; Tennyson, Jonathan; Szidarovszky, Tamás; Császár, Attila G; Berg, Max; Petrignani, Annemieke; Wolf, Andreas

    2012-01-13

    First-principles computations and experimental measurements of transition energies are carried out for vibrational overtone lines of the triatomic hydrogen ion H(3)(+) corresponding to floppy vibrations high above the barrier to linearity. Action spectroscopy is improved to detect extremely weak visible-light spectral lines on cold trapped H(3)(+) ions. A highly accurate potential surface is obtained from variational calculations using explicitly correlated Gaussian wave function expansions. After nonadiabatic corrections, the floppy H(3)(+) vibrational spectrum is reproduced at the 0.1 cm(-1) level up to 16600 cm(-1).

  12. Model-Based, Closed-Loop Control of PZT Creep for Cavity Ring-Down Spectroscopy

    PubMed Central

    McCartt, A D; Ognibene, T J; Bench, G; Turteltaub, K W

    2014-01-01

    Cavity ring-down spectrometers typically employ a PZT stack to modulate the cavity transmission spectrum. While PZTs ease instrument complexity and aid measurement sensitivity, PZT hysteresis hinders the implementation of cavity-length-stabilized, data-acquisition routines. Once the cavity length is stabilized, the cavity’s free spectral range imparts extreme linearity and precision to the measured spectrum’s wavelength axis. Methods such as frequency-stabilized cavity ring-down spectroscopy have successfully mitigated PZT hysteresis, but their complexity limits commercial applications. Described herein is a single-laser, model-based, closed-loop method for cavity length control. PMID:25395738

  13. Model-Based, Closed-Loop Control of PZT Creep for Cavity Ring-Down Spectroscopy.

    PubMed

    McCartt, A D; Ognibene, T J; Bench, G; Turteltaub, K W

    2014-09-01

    Cavity ring-down spectrometers typically employ a PZT stack to modulate the cavity transmission spectrum. While PZTs ease instrument complexity and aid measurement sensitivity, PZT hysteresis hinders the implementation of cavity-length-stabilized, data-acquisition routines. Once the cavity length is stabilized, the cavity's free spectral range imparts extreme linearity and precision to the measured spectrum's wavelength axis. Methods such as frequency-stabilized cavity ring-down spectroscopy have successfully mitigated PZT hysteresis, but their complexity limits commercial applications. Described herein is a single-laser, model-based, closed-loop method for cavity length control.

  14. Development of Methodology and Technology for Identifying and Quantifying Emission Products from Open Burning and Open Detonation Thermal Treatment Methods. Field Test Series A, B, and C. Volume 2, Part B. Quality Assurance and Quality Control. Appendices

    DTIC Science & Technology

    1992-01-01

    the uncertainty. The above method can give an estimate of the precision of the * analysis. However, determining the accuracy can not be done as...speciation has been determined from analyzing model samples as well as comparison with other methods and combinations of other methods with this method . 3...laboratory. The output of the sensor is characterized over its working range and an appropriate response factor determined by linear regression of the

  15. High precision optical fiber Fabry-Perot sensor for gas pressure detection

    NASA Astrophysics Data System (ADS)

    Mao, Yan; Tong, Xing-lin

    2013-09-01

    An optical fiber Fabry-Perot (F-P) sensor with quartz diaphragm for gas pressure testing was designed and fabricated. It consisted of single-mode fiber, hollow glass tube and quartz diaphragm. It uses the double peak demodulation to obtain the initialized cavity length. The variety of cavity length can be calcultated by the single peak demodulation after changing the gas pressure. The results show that the sensor is small in size, whose sensitivity is 19 pm/kPa in the range of the 10 ~ 260 kPa gas pressure. And it has good linearity and repeatability.

  16. Application of mathematical modelling for assessing the biological half-times of chromium and nickel in field studies.

    PubMed Central

    Tossavainen, A; Nurminen, M; Mutanen, P; Tola, S

    1980-01-01

    The biological half-times of urinary chromium and nickel excretion and plasma nickel concentration were calculated for four welders and four electroplaters. A linear one-compartment kinetic model gave estimates of the half-times ranging from 15 to 41 hours for chromium in urine, from 17 to 39 hours for nickel in urine, and from 20 to 34 hours for nickel in plasma. The model allows a precise description to be made of a worker's state of exposure as affected by a varying concentration of the metals in the air. PMID:7426481

  17. Laminar flow burner system with infrared heated spray chamber and condenser.

    PubMed

    Hell, A; Ulrich, W F; Shifrin, N; Ramírez-Muñoz, J

    1968-07-01

    A laminar flow burner is described that provides several advantages in atomic absorption flame photometry. Included in its design is a heated spray chamber followed by a condensing system. This combination improves the concentration level of the analyte in the flame and keeps solvent concentration low. Therefore, sensitivities are significantly improved for most elements relative to cold chamber burners. The burner also contains several safety features. These various design features are discussed in detail, and performance data are given on (a) signal size, (b) signal-to-noise ratio, (c) linearity, (d) working range, (e) precision, and (g) accuracy.

  18. Modeling, system identification, and control of ASTREX

    NASA Technical Reports Server (NTRS)

    Abhyankar, Nandu S.; Ramakrishnan, J.; Byun, K. W.; Das, A.; Cossey, Derek F.; Berg, J.

    1993-01-01

    The modeling, system identification and controller design aspects of the ASTREX precision space structure are presented in this work. Modeling of ASTREX is performed using NASTRAN, TREETOPS and I-DEAS. The models generated range from simple linear time-invariant models to nonlinear models used for large angle simulations. Identification in both the time and frequency domains are presented. The experimental set up and the results from the identification experiments are included. Finally, controller design for ASTREX is presented. Simulation results using this optimal controller demonstrate the controller performance. Finally the future directions and plans for the facility are addressed.

  19. Probabilistic measurement of non-physical constructs during early childhood: Epistemological implications for advancing psychosocial science

    NASA Astrophysics Data System (ADS)

    Bezruczko, N.; Fatani, S. S.

    2010-07-01

    Social researchers commonly compute ordinal raw scores and ratings to quantify human aptitudes, attitudes, and abilities but without a clear understanding of their limitations for scientific knowledge. In this research, common ordinal measures were compared to higher order linear (equal interval) scale measures to clarify implications for objectivity, precision, ontological coherence, and meaningfulness. Raw score gains, residualized raw gains, and linear gains calculated with a Rasch model were compared between Time 1 and Time 2 for observations from two early childhood learning assessments. Comparisons show major inconsistencies between ratings and linear gains. When gain distribution was dense, relatively compact, and initial status near item mid-range, linear measures and ratings were indistinguishable. When Time 1 status was distributed more broadly and magnitude of change variable, ratings were unrelated to linear gain, which emphasizes problematic implications of ordinal measures. Surprisingly, residualized gain scores did not significantly improve ordinal measurement of change. In general, raw scores and ratings may be meaningful in specific samples to establish order and high/low rank, but raw score differences suffer from non-uniform units. Even meaningfulness of sample comparisons, as well as derived proportions and percentages, are seriously affected by rank order distortions and should be avoided.

  20. A Very Fast and Angular Momentum Conserving Tree Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcello, Dominic C., E-mail: dmarce504@gmail.com

    There are many methods used to compute the classical gravitational field in astrophysical simulation codes. With the exception of the typically impractical method of direct computation, none ensure conservation of angular momentum to machine precision. Under uniform time-stepping, the Cartesian fast multipole method of Dehnen (also known as the very fast tree code) conserves linear momentum to machine precision. We show that it is possible to modify this method in a way that conserves both angular and linear momenta.

  1. Achieving sub-millimetre precision with a solid-state full-field heterodyning range imaging camera

    NASA Astrophysics Data System (ADS)

    Dorrington, A. A.; Cree, M. J.; Payne, A. D.; Conroy, R. M.; Carnegie, D. A.

    2007-09-01

    We have developed a full-field solid-state range imaging system capable of capturing range and intensity data simultaneously for every pixel in a scene with sub-millimetre range precision. The system is based on indirect time-of-flight measurements by heterodyning intensity-modulated illumination with a gain modulation intensified digital video camera. Sub-millimetre precision to beyond 5 m and 2 mm precision out to 12 m has been achieved. In this paper, we describe the new sub-millimetre class range imaging system in detail, and review the important aspects that have been instrumental in achieving high precision ranging. We also present the results of performance characterization experiments and a method of resolving the range ambiguity problem associated with homodyne and heterodyne ranging systems.

  2. Relations between basic and specific motor abilities and player quality of young basketball players.

    PubMed

    Marić, Kristijan; Katić, Ratko; Jelicić, Mario

    2013-05-01

    Subjects from 5 first league clubs from Herzegovina were tested with the purpose of determining the relations of basic and specific motor abilities, as well as the effect of specific abilities on player efficiency in young basketball players (cadets). A battery of 12 tests assessing basic motor abilities and 5 specific tests assessing basketball efficiency were used on a sample of 83 basketball players. Two significant canonical correlations, i.e. linear combinations explained the relation between the set of twelve variables of basic motor space and five variables of situational motor abilities. Underlying the first canonical linear combination is the positive effect of the general motor factor, predominantly defined by jumping explosive power, movement speed of the arms, static strength of the arms and coordination, on specific basketball abilities: movement efficiency, the power of the overarm throw, shooting and passing precision, and the skill of handling the ball. The impact of basic motor abilities of precision and balance on specific abilities of passing and shooting precision and ball handling is underlying the second linear combination. The results of regression correlation analysis between the variable set of specific motor abilities and game efficiency have shown that the ability of ball handling has the largest impact on player quality in basketball cadets, followed by shooting precision and passing precision, and the power of the overarm throw.

  3. Evaluation of consumer monitors to measure particulate matter.

    PubMed

    Sousan, Sinan; Koehler, Kirsten; Hallett, Laura; Peters, Thomas M

    2017-05-01

    Recently, inexpensive (<$300) consumer aerosol monitors (CAMs) targeted for use in homes have become available. We evaluated the accuracy, bias, and precision of three CAMs (Foobot from Airoxlab, Speck from Carnegie Mellon University, and AirBeam from HabitatMap) for measuring mass concentrations in occupational settings. In a laboratory study, PM 2.5 measured with the CAMs and a medium-cost aerosol photometer (personal DataRAM 1500, Thermo Scientific) were compared to that from reference instruments for three aerosols (salt, welding fume, and Arizona road dust, ARD) at concentrations up to 8500 μg/m 3 . Three of each type of CAM were included to estimate precision. Compared to reference instruments, mass concentrations measured with the Foobot (r-value = 0.99) and medium-cost photometer (r-value = 0.99) show strong correlation, whereas those from the Speck (r-value range 0.88 - 0.99) and AirBeam (0.7 - 0.96) were less correlated. The Foobot bias was (-12%) for ARD and measurements were similar to the medium-cost instrument. Foobot bias was (< -46%) for salt and welding fume aerosols. Speck bias was at 18% salt for ARD and -86% for welding fume. AirBeam bias was (-36%) for salt and (-83%) for welding fume. All three photometers had a bias (< -82%) for welding fume. Precision was excellent for the Foobot (coefficient of variation range: 5% to 8%) and AirBeam (2% to 9%), but poorer for the Speck (8% to 25%). These findings suggest that the Foobot, with a linear response to different aerosol types and good precision, can provide reasonable estimates of PM 2.5 in the workplace after site-specific calibration to account for particle size and composition.

  4. Determination of Bile Acids in Piglet Bile by Solid Phase Extraction and Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    PubMed

    Mi, Si; Lim, David W; Turner, Justine M; Wales, Paul W; Curtis, Jonathan M

    2016-03-01

    An LC/MS/MS-based method was developed for the determination of individual bile acids (BA) and their conjugates in porcine bile samples. The C18-based solid-phase extraction (SPE) procedure was optimized so that all 19 target BA and their glycine and taurine conjugates were collected with high recoveries for standards (89.1-100.2%). Following this, all 19 compounds were separated and quantified in a single 12 min chromatographic run. The method was validated in terms of linearity, sensitivity, accuracy, precision, and recovery. An LOD in the low ppb range with measured precisions in the range of 0.5-9.3% was achieved. The recoveries for all of the 19 analytes in bile samples were all >80%. The validated method was successfully applied to the profiling of BA and their conjugates in the bile from piglets treated with exogenous glucagon-like peptide-2 (GLP-2) in a preclinical model of neonatal parenteral nutrition-associated liver disease (PNALD). The method developed is rapid and could be easily implemented for routine analysis of BA and their conjugates in other biofluids or tissues.

  5. Determination of ketamine and its main metabolites by liquid chromatography coupled to tandem mass spectrometry in pig plasma: Comparison of extraction methods.

    PubMed

    Ramiole, Cindy; D'Hayer, Benoit; Boudy, Vincent; Legagneux, Josette; Fonsart, Julien; Houzé, Pascal

    2017-11-30

    A rapid, sensitive and specific liquid chromatography coupled to tandem mass spectrometry method was developed for the simultaneous quantification pig plasma of ketamine and its two principal metabolites, norketamine and dehydronorketamine. Three extraction procoles were assessed including acetonitrile precipitation, Oase™ microplate extraction, and liquid-liquid extraction. Oase™ microplate extraction induced no significant matrix effect, important signal/noise ratio and good recoveries, ranging from 82 to 87% for the considered compounds. Using this extraction procedure, the assay was linear in the dynamic range 10-3000ng/mL (R 2 >0.99) regardless of the analytes. Intra- and inter-day accuracies were less than 12% for all compounds and intra- and inter-day precisions expressed as RSD were within <9.9%. Samples were stable in different storage conditions. High ketamine, norketamine and dehydronorketamine concentrations up to 15,000ng/mL can be determined with good precision using appropriate sample dilution. The assay was successfully applied to pig plasma samples to determine the pharmacokinetics of ketamine and the consecutive metabolites after buccal administration of a 4mg/kg ketamine base solutions. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Determination of residual cell culture media components by MEKC.

    PubMed

    Zhang, Junge; Chakraborty, Utpal; Foley, Joe P

    2009-11-01

    Folic acid, hypoxanthine, mycophenolic acid, nicotinic acid, riboflavin, and xanthine are widely used as cell culture media components in monoclonal antibody manufacturing. These components are subsequently removed during the downstream purification processes. This article describes a single MEKC method that can simultaneously determine all the listed compounds with acceptable LOD and LOQ. All the analytes were successfully separated by MEKC using running buffer containing 40 mM SDS, 20 mM sodium phosphate, and 20 mM sodium borate at pH 9.0. The MEKC method was compared to the corresponding CZE method using the same running buffer containing no SDS. The effect of SDS concentration on separation, the pH of the running buffer, and the detection wavelength were studied and optimal MEKC conditions were established. Good linearity was obtained with correlation coefficients of more than 0.99 for all analytes. Specificity, accuracy, and precision were also evaluated. The recovery was in the range of 89-112%. The precision results were in the range of 1.7-4.8%. The experimentally determined data demonstrated that the MEKC method is applicable to the determination of the six analytes in in-process samples from monoclonal antibody manufacturing processes.

  7. A validated HPLC determination of the flavone aglycone diosmetin in human plasma.

    PubMed

    Kanaze, Feras Imad; Bounartzi, Melpomeni I; Niopas, Ioannis

    2004-12-01

    Diosmetin, 3',5,7-trihydroxy-4'-methoxy flavone, is the aglycone of the flavonoid glycoside diosmin that occurs naturally in foods of plant origin. Diosmin exhibits antioxidant and anti-inflammatory activities, improves venous tone and it is used for the treatment of chronic venous insufficiency. Diosmin is hydrolyzed by enzymes of intestinal micro flora before absorption of its aglycone diosmetin. A specific, sensitive, precise, accurate and robust HPLC assay for the determination of diosmetin in human plasma was developed and validated. Diosmetin and the internal standard 7-ethoxycoumarin were isolated from plasma by liquid-liquid extraction and separated on a C8 reversed-phase column with methanol-water-acetic acid (55:43:2, v/v/v) as the mobile phase at 43 degrees C. Peaks were monitored at 344 nm. The method was linear in the 10-300 ng/mL concentration range (r > 0.999). Recovery for diosmetin and internal standard was greater than 89.7 and 86.8%, respectively. Intra-day and inter-day precision for diosmetin ranged from 1.6 to 4.6 and from 2.2 to 5.3%, respectively, and accuracy was better than 97.9%. Copyright 2004 John Wiley & Sons, Ltd.

  8. Picosecond Resolution Time-to-Digital Converter Using Gm-C Integrator and SAR-ADC

    NASA Astrophysics Data System (ADS)

    Xu, Zule; Miyahara, Masaya; Matsuzawa, Akira

    2014-04-01

    A picosecond resolution time-to-digital converter (TDC) is presented. The resolution of a conventional delay chain TDC is limited by the delay of a logic buffer. Various types of recent TDCs are successful in breaking this limitation, but they require a significant calibration effort to achieve picosecond resolution with a sufficient linear range. To address these issues, we propose a simple method to break the resolution limitation without any calibration: a Gm-C integrator followed by a successive approximation register analog-to-digital converter (SAR-ADC). This translates the time interval into charge, and then the charge is quantized. A prototype chip was fabricated in 90 nm CMOS. The measurement results reveal a 1 ps resolution, a -0.6/0.7 LSB differential nonlinearity (DNL), a -1.1/2.3 LSB integral nonlinearity (INL), and a 9-bit range. The measured 11.74 ps single-shot precision is caused by the noise of the integrator. We analyze the noise of the integrator and propose an improved front-end circuit to reduce this noise. The proposal is verified by simulations showing the maximum single-shot precision is less than 1 ps. The proposed front-end circuit can also diminish the mismatch effects.

  9. Development and validation of RP HPLC method to determine nandrolone phenylpropionate in different pharmaceutical formulations.

    PubMed

    Mukherjee, Jayanti; Das, Ayan; Chakrabarty, Uday Sankar; Sahoo, Bijay Kumar; Dey, Goutam; Choudhury, Hira; Pal, Tapan Kumar

    2011-01-01

    This study describes development and subsequent validation of a reversed phase high performance liquid chromatographic (RP-HPLC) method for the estimation of nandrolone phenylpropionate, an anabolic steroid, in bulk drug, in conventional parenteral dosage formulation and in prepared nanoparticle dosage form. The chromatographic system consisted of a Luna Phenomenex, CN (250 mm x 4.6 mm, 5 microm) column, an isocratic mobile phase comprising 10 mM phosphate buffer and acetonitrile (50:50, v/v) and UV detection at 240 nm. Nandrolone phenylpropionate was eluted about 6.3 min with no interfering peaks of excipients used for the preparation of dosage forms. The method was linear over the range from 0.050 to 25 microg/mL in raw drug (r2 = 0.9994). The intra-day and inter-day precision values were in the range of 0.219-0.609% and 0.441-0.875%, respectively. Limits of detection and quantitation were 0.010 microg/mL and 0.050 microg/mL, respectively. The results were validated according to International Conference on Harmonization (ICH) guidelines in parenteral and prepared nanoparticle formulation. The validated HPLC method is simple, sensitive, precise, accurate and reproducible.

  10. Predicting the Maximum Dynamic Strength in Bench Press: The High Precision of the Bar Velocity Approach.

    PubMed

    Loturco, Irineu; Kobal, Ronaldo; Moraes, José E; Kitamura, Katia; Cal Abad, César C; Pereira, Lucas A; Nakamura, Fábio Y

    2017-04-01

    Loturco, I, Kobal, R, Moraes, JE, Kitamura, K, Cal Abad, CC, Pereira, LA, and Nakamura, FY. Predicting the maximum dynamic strength in bench press: the high precision of the bar velocity approach. J Strength Cond Res 31(4): 1127-1131, 2017-The aim of this study was to determine the force-velocity relationship and test the possibility of determining the 1 repetition maximum (1RM) in "free weight" and Smith machine bench presses. Thirty-six male top-level athletes from 3 different sports were submitted to a standardized 1RM bench press assessment (free weight or Smith machine, in randomized order), following standard procedures encompassing lifts performed at 40-100% of 1RM. The mean propulsive velocity (MPV) was measured in all attempts. A linear regression was performed to establish the relationships between bar velocities and 1RM percentages. The actual and predicted 1RM for each exercise were compared using a paired t-test. Although the Smith machine 1RM was higher (10% difference) than the free weight 1RM, in both cases the actual and predicted values did not differ. In addition, the linear relationship between MPV and percentage of 1RM (coefficient of determination ≥95%) allow determination of training intensity based on the bar velocity. The linear relationships between the MPVs and the relative percentages of 1RM throughout the entire range of loads enable coaches to use the MPV to accurately monitor their athletes on a daily basis and accurately determine their actual 1RM without the need to perform standard maximum dynamic strength assessments.

  11. Measurement of HbA1c in Gingival Crevicular Blood Using a High Pressure Liquid Chromatography Procedure

    PubMed Central

    Pesce, Michael A.; Strauss, Shiela M.; Rosedale, Mary; Netterwald, Jane; Wang, Hangli

    2016-01-01

    Objectives To validate an ion exchange high-pressure liquid chromatography (HPLC) method for measuring glycated hemoglobin (HbA1c) in gingival crevicular blood (GCB) spotted on filter paper, for use in screening dental patients for diabetes. Methods We collected the GCB specimens for this study from the oral cavities of patients during dental visits, using rigorous strategies to obtain GCB that was as free of debris as possible. The analytical performance of the HPLC method was determined by measuring the precision, linearity, carryover, stability of HbA1c in GCB, and correlation of HbA1c results in GCB specimens with finger-stick blood (FSB) specimens spotted on filter paper. Results The coefficients of variation (CVs) for the inter- and intrarun precision of the method were less than 2.0%. Linearity ranged between 4.2% and 12.4%; carryover was less than 2.0%, and the stability of the specimen was 6 days at 4°C and as many as 14 days at −70°C. Linear regression analysis comparing the HbA1c results in GCB with FSB yielded a correlation coefficient of 0.993, a slope of 0.981, and an intercept of 0.13. The Bland-Altman plot showed no difference in the HbA1c results from the GCB and FSB specimens at normal, prediabetes, and diabetes HbA1c levels. Conclusion We validated an HPLC method for measuring HbA1c in GCB; this method can be used to screen dental patients for diabetes. PMID:26489673

  12. Precision Control of Multiple Quantum Cascade Lasers for Calibration Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taubman, Matthew S.; Myers, Tanya L.; Pratt, Richard M.

    We present a precision, digitally interfaced current controller for quantum cascade lasers, with demonstrated DC and modulated temperature coefficients of 1- 2 ppm/ºC and 15 ppm/ºC respectively. High linearity digital to analog converters (DACs) together with an ultra-precision voltage reference, produce highly stable, precision voltages. These are in turn selected by a low charge-injection multiplexer (MUX) chip, which are then used to set output currents via a linear current regulator. The controller is operated in conjunction with a power multiplexing unit, allowing one of three lasers to be driven by the controller while ensuring protection of controller and all lasersmore » during operation, standby and switching. Simple ASCII commands sent over a USB connection to a microprocessor located in the current controller operate both the controller (via the DACs and MUX chip) and the power multiplexer.« less

  13. Method validation for control determination of mercury in fresh fish and shrimp samples by solid sampling thermal decomposition/amalgamation atomic absorption spectrometry.

    PubMed

    Torres, Daiane Placido; Martins-Teixeira, Maristela Braga; Cadore, Solange; Queiroz, Helena Müller

    2015-01-01

    A method for the determination of total mercury in fresh fish and shrimp samples by solid sampling thermal decomposition/amalgamation atomic absorption spectrometry (TDA AAS) has been validated following international foodstuff protocols in order to fulfill the Brazilian National Residue Control Plan. The experimental parameters have been previously studied and optimized according to specific legislation on validation and inorganic contaminants in foodstuff. Linearity, sensitivity, specificity, detection and quantification limits, precision (repeatability and within-laboratory reproducibility), robustness as well as accuracy of the method have been evaluated. Linearity of response was satisfactory for the two range concentrations available on the TDA AAS equipment, between approximately 25.0 and 200.0 μg kg(-1) (square regression) and 250.0 and 2000.0 μg kg(-1) (linear regression) of mercury. The residues for both ranges were homoscedastic and independent, with normal distribution. Correlation coefficients obtained for these ranges were higher than 0.995. Limits of quantification (LOQ) and of detection of the method (LDM), based on signal standard deviation (SD) for a low-in-mercury sample, were 3.0 and 1.0 μg kg(-1), respectively. Repeatability of the method was better than 4%. Within-laboratory reproducibility achieved a relative SD better than 6%. Robustness of the current method was evaluated and pointed sample mass as a significant factor. Accuracy (assessed as the analyte recovery) was calculated on basis of the repeatability, and ranged from 89% to 99%. The obtained results showed the suitability of the present method for direct mercury measurement in fresh fish and shrimp samples and the importance of monitoring the analysis conditions for food control purposes. Additionally, the competence of this method was recognized by accreditation under the standard ISO/IEC 17025.

  14. Capillary electrophoresis method with UV-detection for analysis of free amino acids concentrations in food.

    PubMed

    Omar, Mei Musa Ali; Elbashir, Abdalla Ahmed; Schmitz, Oliver J

    2017-01-01

    Simple and inexpensive capillary electrophoresis with UV-detection method (CE-UV) was optimized and validated for determination of six amino acids namely (alanine, asparagine, glutamine, proline, serine and valine) for Sudanese food. Amino acids in the samples were derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) prior to CE-UV analysis. Labeling reaction conditions (100mM borate buffer at pH 8.5, labeling reaction time 60min, temperature 70°C and NBD-Cl concentration 40mM) were systematically investigated. The optimal conditions for the separation were 100mM borate buffer at pH 9.7 and detected at 475nm. The method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision (repeatability) (RSD%) and accuracy (recovery). Good linearity was achieved for all amino acids (r(2)>0.9981) in the concentration range of 2.5-40mg/L. The LODs in the range of 0.32-0.56mg/L were obtained. Recoveries of amino acids ranging from 85% to 108%, (n=3) were obtained. The validated method was successfully applied for the determination of amino acids for Sudanese food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Uranium Detection - Technique Validation Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colletti, Lisa Michelle; Garduno, Katherine; Lujan, Elmer J.

    As a LANL activity for DOE/NNSA in support of SHINE Medical Technologies™ ‘Accelerator Technology’ we have been investigating the application of UV-vis spectroscopy for uranium analysis in solution. While the technique has been developed specifically for sulfate solutions, the proposed SHINE target solutions, it can be adapted to a range of different solution matrixes. The FY15 work scope incorporated technical development that would improve accuracy, specificity, linearity & range, precision & ruggedness, and comparative analysis. Significant progress was achieved throughout FY 15 addressing these technical challenges, as is summarized in this report. In addition, comparative analysis of unknown samples usingmore » the Davies-Gray titration technique highlighted the importance of controlling temperature during analysis (impacting both technique accuracy and linearity/range). To fully understand the impact of temperature, additional experimentation and data analyses were performed during FY16. The results from this FY15/FY16 work were presented in a detailed presentation, LA-UR-16-21310, and an update of this presentation is included with this short report summarizing the key findings. The technique is based on analysis of the most intense U(VI) absorbance band in the visible region of the uranium spectra in 1 M H 2SO 4, at λ max = 419.5 nm.« less

  16. Anodic voltammetric behavior and determination of cefixime in pharmaceutical dosage forms and biological fluids.

    PubMed

    Golcu, Ayşegul; Dogan, Burcu; Ozkan, Sibel A

    2005-10-15

    The voltammetric behavior of cefixime was studied using cyclic, linear sweep, differential pulse and square wave voltammetric techniques. The oxidation of cefixime was irreversible and exhibited diffusion controlled process depending on pH. The oxidation mechanism was proposed and discussed. Different parameters were tested to optimize the conditions for the determination of cefixime. The dependence of current intensities and potentials on pH, concentration, scan rate, nature of the buffer was investigated. According to the linear relationship between the peak current and the concentration, differential pulse (DPV) and square wave (SWV) voltammetric methods for cefixime assay in pharmaceutical dosage forms and biological fluids were developed. For the determination of cefixime were proposed in acetate buffer at pH 4.5, which allows quantitation over the 6 x 10(-6)-2 x 10(-4)M range in supporting electrolyte and spiked serum sample; 8 x 10(-6)-2 x 10(-4)M range in urine sample; 6 x 10(-6)-1 x 10(-4)M range in breast milk samples for both techniques. The repeatability, reproducibility, precision and accuracy of the methods in all media were investigated. No electroactive interferences from the excipients and endogenous substances were found in the pharmaceutical dosage forms and in the biological samples, respectively.

  17. Performance evaluation of Abbott CELL-DYN Ruby for routine use.

    PubMed

    Lehto, T; Hedberg, P

    2008-10-01

    CELL-DYN Ruby is a new automated hematology analyzer suitable for routine use in small laboratories and as a back-up or emergency analyzer in medium- to high-volume laboratories. The analyzer was evaluated by comparing the results from the CELL-DYN((R)) Ruby with the results obtained from CELL-DYN Sapphire . Precision, linearity, and carryover between patient samples were also assessed. Precision was good at all levels for the routine cell blood count (CBC) parameters, CV% being or= 0.98) with CELL-DYN Sapphire for the CBC parameters. For the absolute reticulocyte count, R(2) was 0.82. In the white blood cell (WBC) differentials, the between-days precision was good for all parameters (CV%: or= 0.97), and the correlation coefficient for absolute monocyte count and monocyte percentage were 0.91 and 0.87, respectively. For absolute basophil count and basophil percentage the correlations were weaker (R(2) = 0.46 and 0.34, respectively). Carryover was minimal for all the parameters studied. The linearities of WBC, red blood cell, PLTs, and hemoglobin were acceptable within the tested ranges. In conclusion, the results of the evaluation showed the performance of CELL-DYN Ruby to be good.

  18. Linear and Nonlinear Molecular Spectroscopy with Laser Frequency Combs

    NASA Astrophysics Data System (ADS)

    Picque, Nathalie

    2013-06-01

    The regular pulse train of a mode-locked femtosecond laser can give rise to a comb spectrum of millions of laser modes with a spacing precisely equal to the pulse repetition frequency. Laser frequency combs were conceived a decade ago as tools for the precision spectroscopy of atomic hydrogen. They are now becoming enabling tools for an increasing number of applications, including molecular spectroscopy. Recent experiments of multi-heterodyne frequency comb Fourier transform spectroscopy (also called dual-comb spectroscopy) have demonstrated that the precisely spaced spectral lines of a laser frequency comb can be harnessed for new techniques of linear absorption spectroscopy. The first proof-of-principle experiments have demonstrated a very exciting potential of dual-comb spectroscopy without moving parts for ultra-rapid and ultra-sensitive recording of complex broad spectral bandwidth molecular spectra. Compared to conventional Michelson-based Fourier transform spectroscopy, recording times could be shortened from seconds to microseconds, with intriguing prospects for spectroscopy of short lived transient species. The resolution improves proportionally to the measurement time. Therefore longer recordings allow high resolution spectroscopy of molecules with extreme precision, since the absolute frequency of each laser comb line can be known with the accuracy of an atomic clock. Moreover, since laser frequency combs involve intense ultrashort laser pulses, nonlinear interactions can be harnessed. Broad spectral bandwidth ultra-rapid nonlinear molecular spectroscopy and imaging with two laser frequency combs is demonstrated with coherent Raman effects and two-photon excitation. Real-time multiplex accessing of hyperspectral images may dramatically expand the range of applications of nonlinear microscopy. B. Bernhardt et al., Nature Photonics 4, 55-57 (2010); A. Schliesser et al. Nature Photonics 6, 440-449 (2012); T. Ideguchi et al. arXiv:1201.4177 (2012) T. Ideguchi et al., Optics letters 37, 4498-4500 (2012); T. Ideguchi et al. arXiv:1302.2414 (2013)

  19. Robust post-stall perching with a simple fixed-wing glider using LQR-Trees.

    PubMed

    Moore, Joseph; Cory, Rick; Tedrake, Russ

    2014-06-01

    Birds routinely execute post-stall maneuvers with a speed and precision far beyond the capabilities of our best aircraft control systems. One remarkable example is a bird exploiting post-stall pressure drag in order to rapidly decelerate to land on a perch. Stall is typically associated with a loss of control authority, and it is tempting to attribute this agility of birds to the intricate morphology of the wings and tail, to their precision sensing apparatus, or their ability to perform thrust vectoring. Here we ask whether an extremely simple fixed-wing glider (no propeller) with only a single actuator in the tail is capable of landing precisely on a perch from a large range of initial conditions. To answer this question, we focus on the design of the flight control system; building upon previous work which used linear feedback control design based on quadratic regulators (LQR), we develop nonlinear feedback control based on nonlinear model-predictive control and 'LQR-Trees'. Through simulation using a flat-plate model of the glider, we find that both nonlinear methods are capable of achieving an accurate bird-like perching maneuver from a large range of initial conditions; the 'LQR-Trees' algorithm is particularly useful due to its low computational burden at runtime and its inherent performance guarantees. With this in mind, we then implement the 'LQR-Trees' algorithm on real hardware and demonstrate a 95 percent perching success rate over 147 flights for a wide range of initial speeds. These results suggest that, at least in the absence of significant disturbances like wind gusts, complex wing morphology and sensing are not strictly required to achieve accurate and robust perching even in the post-stall flow regime.

  20. Determination of very low levels of 5-(hydroxymethyl)-2-furaldehyde (HMF) in natural honey: comparison between the HPLC technique and the spectrophotometric white method.

    PubMed

    Truzzi, Cristina; Annibaldi, Anna; Illuminati, Silvia; Finale, Carolina; Rossetti, Monica; Scarponi, Giuseppe

    2012-07-01

    In this work we compared 2 official methods for the determination of HMF in honey, the spectrophotometric White method and the HPLC method (International Honey Commission) for the determination of HMF in unifloral honey and honeydew samples with a very low HMF content (<4 mg/kg), which is the most critical determination in terms of accuracy and precision of methods. In honey solutions, the limits of quantification for HPLC and White methods are 0.83 mg/L and 0.67 mg/L, respectively, and the linearity range is confirmed up to 20 mg/L for the HPLC method and up to 5 mg/L for the White method. In honeys with HMF >5 mg/kg, the molar extinction coefficient is 15369, lower than the literature value of 16830, and should be used for HMF determination. For samples with HMF content in the range 1-4 mg/kg the accuracy of the 2 methods is comparable both for unifloral and honeydew samples, whereas as regards precision, the HPLC method gives better results (3.5% compared with 6.4% for the White method). So, in general, the HPLC method seems to be more appropriate for the determination of HMF in honey in the range 1-4 mg/kg thanks to its greater precision, but for samples with a HMF content of less than 1 mg/kg the analyses are inaccurate for both methods. This work can help governmental and private laboratories that perform food analyses to choose the best method for the determination of HMF at very low levels in unifloral honey and honeydew samples. © 2012 Institute of Food Technologists®

  1. Simple and ultra-fast recognition and quantitation of compounded monoclonal antibodies: Application to flow injection analysis combined to UV spectroscopy and matching method.

    PubMed

    Jaccoulet, E; Schweitzer-Chaput, A; Toussaint, B; Prognon, P; Caudron, E

    2018-09-01

    Compounding of monoclonal antibody (mAbs) constantly increases in hospital. Quality control (QC) of the compounded mAbs based on quantification and identification is required to prevent potential errors and fast method is needed to manage outpatient chemotherapy administration. A simple and ultra-fast (less than 30 s) method using flow injection analysis associated to least square matching method issued from the analyzer software was performed and evaluated for the routine hospital QC of three compounded mAbs: bevacizumab, infliximab and rituximab. The method was evaluated through qualitative and quantitative parameters. Preliminary analysis of the UV absorption and second derivative spectra of the mAbs allowed us to adapt analytical conditions according to the therapeutic range of the mAbs. In terms of quantitative QC, linearity, accuracy and precision were assessed as specified in ICH guidelines. Very satisfactory recovery was achieved and the RSD (%) of the intermediate precision were less than 1.1%. Qualitative analytical parameters were also evaluated in terms of specificity, sensitivity and global precision through a matrix of confusion. Results showed to be concentration and mAbs dependant and excellent (100%) specificity and sensitivity were reached within specific concentration range. Finally, routine application on "real life" samples (n = 209) from different batch of the three mAbs complied with the specifications of the quality control i.e. excellent identification (100%) and ± 15% of targeting concentration belonging to the calibration range. The successful use of the combination of second derivative spectroscopy and partial least square matching method demonstrated the interest of FIA for the ultra-fast QC of mAbs after compounding using matching method. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Integrated Analytic and Linearized Inverse Kinematics for Precise Full Body Interactions

    NASA Astrophysics Data System (ADS)

    Boulic, Ronan; Raunhardt, Daniel

    Despite the large success of games grounded on movement-based interactions the current state of full body motion capture technologies still prevents the exploitation of precise interactions with complex environments. This paper focuses on ensuring a precise spatial correspondence between the user and the avatar. We build upon our past effort in human postural control with a Prioritized Inverse Kinematics framework. One of its key advantage is to ease the dynamic combination of postural and collision avoidance constraints. However its reliance on a linearized approximation of the problem makes it vulnerable to the well-known full extension singularity of the limbs. In such context the tracking performance is reduced and/or less believable intermediate postural solutions are produced. We address this issue by introducing a new type of analytic constraint that smoothly integrates within the prioritized Inverse Kinematics framework. The paper first recalls the background of full body 3D interactions and the advantages and drawbacks of the linearized IK solution. Then the Flexion-EXTension constraint (FLEXT in short) is introduced for the partial position control of limb-like articulated structures. Comparative results illustrate the interest of this new type of integrated analytical and linearized IK control.

  3. First patients treated with a 1.5 T MRI-Linac: clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment

    NASA Astrophysics Data System (ADS)

    Raaymakers, B. W.; Jürgenliemk-Schulz, I. M.; Bol, G. H.; Glitzner, M.; Kotte, A. N. T. J.; van Asselen, B.; de Boer, J. C. J.; Bluemink, J. J.; Hackett, S. L.; Moerland, M. A.; Woodings, S. J.; Wolthaus, J. W. H.; van Zijp, H. M.; Philippens, M. E. P.; Tijssen, R.; Kok, J. G. M.; de Groot-van Breugel, E. N.; Kiekebosch, I.; Meijers, L. T. C.; Nomden, C. N.; Sikkes, G. G.; Doornaert, P. A. H.; Eppinga, W. S. C.; Kasperts, N.; Kerkmeijer, L. G. W.; Tersteeg, J. H. A.; Brown, K. J.; Pais, B.; Woodhead, P.; Lagendijk, J. J. W.

    2017-12-01

    The integration of 1.5 T MRI functionality with a radiotherapy linear accelerator (linac) has been pursued since 1999 by the UMC Utrecht in close collaboration with Elekta and Philips. The idea behind this integrated device is to offer unrivalled, online and real-time, soft-tissue visualization of the tumour and the surroundings for more precise radiation delivery. The proof of concept of this device was given in 2009 by demonstrating simultaneous irradiation and MR imaging on phantoms, since then the device has been further developed and commercialized by Elekta. The aim of this work is to demonstrate the clinical feasibility of online, high-precision, high-field MRI guidance of radiotherapy using the first clinical prototype MRI-Linac. Four patients with lumbar spine bone metastases were treated with a 3 or 5 beam step-and-shoot IMRT plan. The IMRT plan was created while the patient was on the treatment table and based on the online 1.5 T MR images; pre-treatment CT was deformably registered to the online MRI to obtain Hounsfield values. Bone metastases were chosen as the first site as these tumors can be clearly visualized on MRI and the surrounding spine bone can be detected on the integrated portal imager. This way the portal images served as an independent verification of the MRI based guidance to quantify the geometric precision of radiation delivery. Dosimetric accuracy was assessed post-treatment from phantom measurements with an ionization chamber and film. Absolute doses were found to be highly accurate, with deviations ranging from 0.0% to 1.7% in the isocenter. The geometrical, MRI based targeting as confirmed using portal images was better than 0.5 mm, ranging from 0.2 mm to 0.4 mm. In conclusion, high precision, high-field, 1.5 T MRI guided radiotherapy is clinically feasible.

  4. Least median of squares and iteratively re-weighted least squares as robust linear regression methods for fluorimetric determination of α-lipoic acid in capsules in ideal and non-ideal cases of linearity.

    PubMed

    Korany, Mohamed A; Gazy, Azza A; Khamis, Essam F; Ragab, Marwa A A; Kamal, Miranda F

    2018-06-01

    This study outlines two robust regression approaches, namely least median of squares (LMS) and iteratively re-weighted least squares (IRLS) to investigate their application in instrument analysis of nutraceuticals (that is, fluorescence quenching of merbromin reagent upon lipoic acid addition). These robust regression methods were used to calculate calibration data from the fluorescence quenching reaction (∆F and F-ratio) under ideal or non-ideal linearity conditions. For each condition, data were treated using three regression fittings: Ordinary Least Squares (OLS), LMS and IRLS. Assessment of linearity, limits of detection (LOD) and quantitation (LOQ), accuracy and precision were carefully studied for each condition. LMS and IRLS regression line fittings showed significant improvement in correlation coefficients and all regression parameters for both methods and both conditions. In the ideal linearity condition, the intercept and slope changed insignificantly, but a dramatic change was observed for the non-ideal condition and linearity intercept. Under both linearity conditions, LOD and LOQ values after the robust regression line fitting of data were lower than those obtained before data treatment. The results obtained after statistical treatment indicated that the linearity ranges for drug determination could be expanded to lower limits of quantitation by enhancing the regression equation parameters after data treatment. Analysis results for lipoic acid in capsules, using both fluorimetric methods, treated by parametric OLS and after treatment by robust LMS and IRLS were compared for both linearity conditions. Copyright © 2018 John Wiley & Sons, Ltd.

  5. Application of an activated carbon-based support for magnetic solid phase extraction followed by spectrophotometric determination of tartrazine in commercial beverages.

    PubMed

    Rodríguez, José A; Escamilla-Lara, Karen A; Guevara-Lara, Alfredo; Miranda, Jose M; Páez-Hernández, Ma Elena

    2015-01-01

    A method is presented for magnetic solid phase extraction of tartrazine from nonalcoholic beverages. The method involves the extraction and clean-up by activated carbon covered with magnetite dispersed in the sample, followed by the magnetic isolation and desorption of the analyte by basified methanol. The tartrazine eluted from the magnetic support was determined by spectrophotometry. Under optimal conditions, the linear range of the calibration curve ranges from 3 to 30 mg L(-1), with a limit of detection of 1 mg L(-1). The method was validated by comparing the results with those obtained by HPLC. A precision of <5.0% was obtained in all cases and no significant differences were observed (P < 0.05).

  6. Application of an Activated Carbon-Based Support for Magnetic Solid Phase Extraction Followed by Spectrophotometric Determination of Tartrazine in Commercial Beverages

    PubMed Central

    Rodríguez, José A.; Escamilla-Lara, Karen A.; Guevara-Lara, Alfredo; Miranda, Jose M.

    2015-01-01

    A method is presented for magnetic solid phase extraction of tartrazine from nonalcoholic beverages. The method involves the extraction and clean-up by activated carbon covered with magnetite dispersed in the sample, followed by the magnetic isolation and desorption of the analyte by basified methanol. The tartrazine eluted from the magnetic support was determined by spectrophotometry. Under optimal conditions, the linear range of the calibration curve ranges from 3 to 30 mg L−1, with a limit of detection of 1 mg L−1. The method was validated by comparing the results with those obtained by HPLC. A precision of <5.0% was obtained in all cases and no significant differences were observed (P < 0.05). PMID:25873965

  7. Reconstructing baryon oscillations: A Lagrangian theory perspective

    NASA Astrophysics Data System (ADS)

    Padmanabhan, Nikhil; White, Martin; Cohn, J. D.

    2009-03-01

    Recently Eisenstein and collaborators introduced a method to “reconstruct” the linear power spectrum from a nonlinearly evolved galaxy distribution in order to improve precision in measurements of baryon acoustic oscillations. We reformulate this method within the Lagrangian picture of structure formation, to better understand what such a method does, and what the resulting power spectra are. We show that reconstruction does not reproduce the linear density field, at second order. We however show that it does reduce the damping of the oscillations due to nonlinear structure formation, explaining the improvements seen in simulations. Our results suggest that the reconstructed power spectrum is potentially better modeled as the sum of three different power spectra, each dominating over different wavelength ranges and with different nonlinear damping terms. Finally, we also show that reconstruction reduces the mode-coupling term in the power spectrum, explaining why miscalibrations of the acoustic scale are reduced when one considers the reconstructed power spectrum.

  8. Determination of myriocin in natural and cultured Cordyceps cicadae using 9-fluorenylmethyl chloroformate derivatization and high-performance liquid chromatography with UV-detection.

    PubMed

    Yu, Jiawen; Xu, Hongjuan; Mo, Zhihong; Zhu, Huali; Mao, Xianbing

    2009-07-01

    A simple and sensitive reversed-phase liquid chromatographic method, based on the precolumn derivatization with 9-fluorenylmethyl chloroformate, was developed for the determination of myriocin. The derivatization reaction was performed in organic solvents of pyridine and tetrahydrofuran at 40 degrees C. Several factors influencing the derivative yield were investigated and optimized. The formed derivative was stable for more than 24 h at room temperature. The detection wavelength was 262 nm. The system offered the following analytical parameters: the limit of detection was 0.045 microg ml(-1), the linear correlation coefficient was 0.9963 and the linear range response was from 2.0 to 500.0 microg ml(-1). The precision of the method was <2.0%. As a preliminary application, the method has been successfully applied to the determination of myriocin in natural and cultured Cordyceps cicadae.

  9. New Terfenol-D actuator design with applications to multiple DOF active vibration control

    NASA Astrophysics Data System (ADS)

    Haynes, Leonard S.; Geng, Zheng J.; Teter, Joseph P.

    1993-09-01

    A linear actuator system for multi-dimensional structure control using the magnetostrictive material Terfenol-D has been designed, built, and tested by the Intelligent Automation, Inc. The actuator assembly incorporates an instrumented Terfenol-D rod, an excitation coil to provide the magnetic field, a permanent magnet assembly to provide a magnetic bias field, and a mechanical preload mechanism. The prototype of the actuator is 2.0 inches in diameter and 8 inches long, and provides a peak-to-peak stroke of 0.01 inches. A linear model was also established to characterize the behavior of the actuator for small motion. Based on the prototype of the actuator, we have performed a study of a six degree-of-freedom active vibration isolation system using a Stewart Platform in a new configuration. IAI's final system is intended for precision control of a wide range of space-based structures as well as earth- base systems.

  10. Plasma L-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-IAF) and fluorescence detection.

    PubMed

    Sotgia, Salvatore; Pisanu, Elisabetta; Pintus, Gianfranco; Erre, Gian Luca; Pinna, Gerard Aime; Deiana, Luca; Carru, Ciriaco; Zinellu, Angelo

    2013-01-01

    Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried out by HPLC on an ODS-2 C-18 sperisorb column by using a linear gradient elution and by HPCE on an uncoated fused silica capillary, 50 µm id, and 60 cm length. The methods were validated and found to be linear in the range of 0.3 to 10 µmol/l. The limit of quantification was 0.27 µmol/l for HPCE and 0.15 µmol/l for HPLC. The variations for intra- and inter-assay precision were around 6 RSD%, and the mean recovery accuracy close to 100% (96.11%).

  11. Plasma L-Ergothioneine Measurement by High-Performance Liquid Chromatography and Capillary Electrophoresis after a Pre-Column Derivatization with 5-Iodoacetamidofluorescein (5-IAF) and Fluorescence Detection

    PubMed Central

    Sotgia, Salvatore; Pisanu, Elisabetta; Pintus, Gianfranco; Erre, Gian Luca; Pinna, Gerard Aime; Deiana, Luca; Carru, Ciriaco; Zinellu, Angelo

    2013-01-01

    Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried out by HPLC on an ODS-2 C-18 sperisorb column by using a linear gradient elution and by HPCE on an uncoated fused silica capillary, 50 µm id, and 60 cm length. The methods were validated and found to be linear in the range of 0.3 to 10 µmol/l. The limit of quantification was 0.27 µmol/l for HPCE and 0.15 µmol/l for HPLC. The variations for intra- and inter-assay precision were around 6 RSD%, and the mean recovery accuracy close to 100% (96.11%). PMID:23922985

  12. The all-fiber cladding-pumped Yb-doped gain-switched laser.

    PubMed

    Larsen, C; Hansen, K P; Mattsson, K E; Bang, O

    2014-01-27

    Gain-switching is an alternative pulsing technique of fiber lasers, which is power scalable and has a low complexity. From a linear stability analysis of rate equations the relaxation oscillation period is derived and from it, the pulse duration is defined. Good agreement between the measured pulse duration and the theoretical prediction is found over a wide range of parameters. In particular we investigate the influence of an often present length of passive fiber in the cavity and show that it introduces a finite minimum in the achievable pulse duration. This minimum pulse duration is shown to occur at longer active fibers length with increased passive length of fiber in the cavity. The peak power is observed to depend linearly on the absorbed pump power and be independent of the passive fiber length. Given these conclusions, the pulse energy, duration, and peak power can be estimated with good precision.

  13. Galaxy Clustering, Photometric Redshifts and Diagnosis of Systematics in the DES Science Verification Data

    DOE PAGES

    Crocce, M.

    2015-12-09

    We study the clustering of galaxies detected at i < 22.5 in the Science Verification observations of the Dark Energy Survey (DES). Two-point correlation functions are measured using 2.3 × 106 galaxies over a contiguous 116 deg 2 region in five bins of photometric redshift width Δz = 0.2 in the range 0.2 < z < 1.2. The impact of photometric redshift errors is assessed by comparing results using a template-based photo-zalgorithm (BPZ) to a machine-learning algorithm (TPZ). A companion paper presents maps of several observational variables (e.g. seeing, sky brightness) which could modulate the galaxy density. Here we characterizemore » and mitigate systematic errors on the measured clustering which arise from these observational variables, in addition to others such as Galactic dust and stellar contamination. After correcting for systematic effects, we then measure galaxy bias over a broad range of linear scales relative to mass clustering predicted from the Planck Λ cold dark matter model, finding agreement with the Canada-France-Hawaii Telescope Legacy Survey (CFHTLS) measurements with χ 2 of 4.0 (8.7) with 5 degrees of freedom for the TPZ (BPZ) redshifts. Furthermore, we test a ‘linear bias’ model, in which the galaxy clustering is a fixed multiple of the predicted non-linear dark matter clustering. The precision of the data allows us to determine that the linear bias model describes the observed galaxy clustering to 2.5 percent accuracy down to scales at least 4–10 times smaller than those on which linear theory is expected to be sufficient.« less

  14. Galaxy Clustering, Photometric Redshifts and Diagnosis of Systematics in the DES Science Verification Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crocce, M.

    We study the clustering of galaxies detected at i < 22.5 in the Science Verification observations of the Dark Energy Survey (DES). Two-point correlation functions are measured using 2.3 × 106 galaxies over a contiguous 116 deg 2 region in five bins of photometric redshift width Δz = 0.2 in the range 0.2 < z < 1.2. The impact of photometric redshift errors is assessed by comparing results using a template-based photo-zalgorithm (BPZ) to a machine-learning algorithm (TPZ). A companion paper presents maps of several observational variables (e.g. seeing, sky brightness) which could modulate the galaxy density. Here we characterizemore » and mitigate systematic errors on the measured clustering which arise from these observational variables, in addition to others such as Galactic dust and stellar contamination. After correcting for systematic effects, we then measure galaxy bias over a broad range of linear scales relative to mass clustering predicted from the Planck Λ cold dark matter model, finding agreement with the Canada-France-Hawaii Telescope Legacy Survey (CFHTLS) measurements with χ 2 of 4.0 (8.7) with 5 degrees of freedom for the TPZ (BPZ) redshifts. Furthermore, we test a ‘linear bias’ model, in which the galaxy clustering is a fixed multiple of the predicted non-linear dark matter clustering. The precision of the data allows us to determine that the linear bias model describes the observed galaxy clustering to 2.5 percent accuracy down to scales at least 4–10 times smaller than those on which linear theory is expected to be sufficient.« less

  15. Development of a direct competitive enzyme-linked immunosorbent assay for parathion residue in food samples.

    PubMed

    Gui, Wen-Jun; Liu, Yi-Hua; Wang, Chun-Mei; Liang, Xiao; Zhu, Guo-Nian

    2009-10-01

    A heterologous direct competitive enzyme-linked immunosorbent assay (ELISA) for parathion residue determination is described based on a monoclonal antibody and a new competitor. The effects of several physicochemical factors, such as methanol concentration, ionic strength, pH value, and sample matrix, on the performance of the ELISA were optimized for the sake of obtaining a satisfactory assay sensitivity. Results showed that when the assay medium was in the optimized condition (phosphate buffer solution [PBS] containing 10% [v/v] methanol and 0.2 mol/L NaCl at a pH value of 5.0), the sensitivity (estimated as the IC(50) value) and the limit of detection (LOD, estimated as the IC(10) value) were 1.19 and 0.08 ng/ml, respectively. The precision investigation indicated that the intraassay precision values all were below 10% and that the interassay precision values ranged from 4.89 to 19.12%. In addition, the developed ELISA showed a good linear correlation (r(2)=0.9962) to gas chromatography within the analyte's concentration range of 0.1 to 16 ng/ml. When applied to the fortified samples (parathion adding level: 5-15 microg/kg), the developed ELISA presented mean recoveries of 127.46, 122.52, 91.92, 124.01, 129.72, 99.37, and 87.17% for tomato, cucumber, banana, apple, orange, pear, and sugarcane, respectively. Results indicated that the established ELISA is a potential tool for parathion residue determination.

  16. Msn2 Coordinates a Stoichiometric Gene Expression Program

    PubMed Central

    Stewart-Ornstein, Jacob; Nelson, Christopher; DeRisi, Joe; Weissman, Jonathan S.; El-Samad, Hana

    2014-01-01

    Summary Background Many cellular processes operate in an “analog” regime in which the magnitude of the response is precisely tailored to the intensity of the stimulus. In order to maintain the coherence of such responses, the cell must provide for proportional expression of multiple target genes across a wide dynamic range of induction states. Our understanding of the strategies used to achieve graded gene regulation is limited. Results In this work, we document a relationship between stress responsive gene expression and the transcription factor Msn2 that is graded over a large range of Msn2 cocnentrations. We use computational modeling, in vivo, and in vitro analysis to dissect the roots of this relationship. Our studies reveal a simple and general strategy based on non-cooperative low-affinity interactions between Msn2 and its cognate binding sites, as well as competition over a large number of Msn2 binding sites in the genome relative to the number of Msn2 molecules. Conclusions In addition to enabling precise tuning of gene expression to the state of the environment, this strategy ensures co-linear activation of target genes, allowing for stoichiometric expression of large groups of genes without extensive promoter tuning. Furthermore, such a strategy enables precise modulation of the activity of any given promoter by addition of binding sites without altering the qualitative relationship between different genes in a regulon. This feature renders a given regulon highly ‘evolvable’. PMID:24210615

  17. Method validation for the determination of ochratoxin A in green and soluble coffee by immunoaffinity column cleanup and liquid chromatography.

    PubMed

    Diaz, G J; Ariza, D; Perilla, N S

    2004-06-01

    A method was validated for the determination of ochratoxin A (OTA) in soluble and green coffee. Performance parameters evaluated included selectivity, accuracy, intermediate precision, linearity, limit of detection, limit of quantitation, and ruggedness. The method was found to be selective for OTA in both matrices tested. Recovery rates from soluble coffee samples ranged from 73.5 to 91.2%, and from green coffee samples from 68.7 to 84.5%. The intermediate precision (RSDr) was between 9.1 and 9.4% for soluble coffee and between 14.3 and 15.5% for green coffee analysis. The linearity of the standard calibration curve (r(2)) was <0.999 for OTA levels of 1.0-20.0 μg/kg in coffee samples. The limit of detection was determined to be 0.01 ng of OTA on column, while the limit of quantitation was found to be 0.03 ng on column. The limit of quantitation is equivalent to 0.6 μg/kg in soluble coffee samples and 0.3 μg/kg in green coffee samples. The results of the ruggedness trial showed two factors are critical for soluble coffee analysis: the extraction method, and the flow rate of the mobile phase. For green coffee analysis two critical factors detected were the extraction method and the storage temperature of the immunoaffinity column.Five samples of soluble coffee and 42 of green coffee were analysed using the validated method. All soluble coffee samples contained OTA at levels that ranged from 8.4 to 13.9 μg/kg. Six of the 42 green coffee samples analysed (14.3%) contained OTA at levels ranging from 0.9 to 19.4 μg/kg. The validated method can be used to monitor OTA levels in Colombian coffee for export or for local consumption.

  18. Assessing disease stress and modeling yield losses in alfalfa

    NASA Astrophysics Data System (ADS)

    Guan, Jie

    Alfalfa is the most important forage crop in the U.S. and worldwide. Fungal foliar diseases are believed to cause significant yield losses in alfalfa, yet, little quantitative information exists regarding the amount of crop loss. Different fungicides and application frequencies were used as tools to generate a range of foliar disease intensities in Ames and Nashua, IA. Visual disease assessments (disease incidence, disease severity, and percentage defoliation) were obtained weekly for each alfalfa growth cycle (two to three growing cycles per season). Remote sensing assessments were performed using a hand-held, multispectral radiometer to measure the amount and quality of sunlight reflected from alfalfa canopies. Factors such as incident radiation, sun angle, sensor height, and leaf wetness were all found to significantly affect the percentage reflectance of sunlight reflected from alfalfa canopies. The precision of visual and remote sensing assessment methods was quantified. Precision was defined as the intra-rater repeatability and inter-rater reliability of assessment methods. F-tests, slopes, intercepts, and coefficients of determination (R2) were used to compare assessment methods for precision. Results showed that among the three visual disease assessment methods (disease incidence, disease severity, and percentage defoliation), percentage defoliation had the highest intra-rater repeatability and inter-rater reliability. Remote sensing assessment method had better precision than the percentage defoliation assessment method based upon higher intra-rater repeatability and inter-rater reliability. Significant linear relationships between canopy reflectance (810 nm), percentage defoliation and yield were detected using linear regression and percentage reflectance (810 nm) assessments were found to have a stronger relationship with yield than percentage defoliation assessments. There were also significant linear relationships between percentage defoliation, dry weight, percentage reflectance (810 nm), and green leaf area index (GLAI). Percentage reflectance (810 nm) assessments had a stronger relationship with dry weight and green leaf area index than percentage defoliation assessments. Our research conclusively demonstrates that percentage reflectance measurements can be used to nondestructively assess green leaf area index which is a direct measure of plant health and an indirect measure of productivity. This research conclusively demonstrates that remote sensing is superior to visual assessment method to assess alfalfa stress and to model yield and GLAI in the alfalfa foliar disease pathosystem.

  19. Use of Protein G Microcolumns in Chromatographic Immunoassays: A Comparison of Competitive Binding Formats

    PubMed Central

    Pfaunmiller, Erika L.; Anguizola, Jeanethe A.; Milanuk, Mitchell L.; Carter, NaTasha; Hage, David S.

    2016-01-01

    Affinity microcolumns containing protein G were used as general platforms for creating chromatographic-based competitive binding immunoassays. Human serum albumin (HSA) was used as a model target for this work and HSA tagged with a near infrared fluorescent dye was utilized as the label. The protein G microcolumns were evaluated for use in several assay formats, including both solution-based and column-based competitive binding immunoassays and simultaneous or sequential injection formats. All of these methods were characterized by using the same amounts of labeled HSA and anti-HSA antibodies per sample, as chosen for the analysis of a protein target in the low-to-mid ng/mL range. The results were used to compare these formats in terms of their response, precision, limits of detection, and analysis time. All these methods gave detection limits in the range of 8–19 ng/mL and precisions ranging from ± 5% to ± 10% when using an injection flow rate of 0.10 mL/min. The column-based sequential injection immunoassay provided the best limit of detection and the greatest change in response at low target concentrations, while the solution-based simultaneous injection method had the broadest linear and dynamic ranges. These results provided valuable guidelines that can be employed to develop and extend the use of protein G microcolumns and these competitive binding formats to other protein biomarkers or biological agents of clinical or pharmaceutical interest. PMID:26777776

  20. Large-scale performance evaluation of Accu-Chek inform II point-of-care glucose meters.

    PubMed

    Jeong, Tae-Dong; Cho, Eun-Jung; Ko, Dae-Hyun; Lee, Woochang; Chun, Sail; Hong, Ki-Sook; Min, Won-Ki

    2016-12-01

    The aim of this study was to report the experience of large-scale performance evaluation of 238 Accu-Chek Inform II point-of-care (POC) glucose meters in a single medical setting. The repeatability of 238 POC devices, the within-site imprecision of 12 devices, and the linearity of 49 devices were evaluated using glucose control solutions. The glucose results of 24 POC devices and central laboratory were compared using patient samples. Mean concentration of control solutions was 2.39 mmol/L for Level 1 and 16.52 mmol/L for Level 2. The pooled repeatability coefficient of variation (CV) of the 238 devices was 2.0% for Level 1 and 1.6% for Level 2. The pooled within-site imprecision CV and reproducibility CV of the 12 devices were 2.7% and 2.7% for Level 1, and 1.9%, and 1.9% for Level 2, respectively. The test results of all 49 devices were linear within analytical measurement range from 1.55-31.02 mmol/L. The correlation coefficient for individual POC devices ranged from 0.9967-0.9985. The total correlation coefficient for the 24 devices was 0.998. The Accu-Chek Inform II POC blood glucose meters performed well in terms of precision, linearity, and correlation evaluations. Consensus guidelines for the large-scale performance evaluations of POC devices are required.

  1. A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form.

    PubMed

    Darsazan, Bahar; Shafaati, Alireza; Mortazavi, Seyed Alireza; Zarghi, Afshin

    2017-01-01

    A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C 18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 mL/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a retention time of 5.8 ± 0.01 min. No interferences were observed from its stress degradation products. The method was validated according to the international guidelines. Linear regression analysis of data for the calibration plot showed a linear relationship between peak area and concentration over the range of 0.5-16 μg/mL; the regression coefficient was 0.9999and the linear regression equation was y = 24844x-2941.3. The detection (LOD) and quantification (LOQ) limits were 0.12 and 0.35 μg/mL, respectively. The results proved the method was fast (analysis time less than 7 min), precise, reproducible, and accurate for analysis of ADV over a wide range of concentration. The proposed specific method was used for routine quantification of ADV in pharmaceutical bulk and a tablet dosage form.

  2. Determination of enantiomeric vigabatrin by derivatization with diacetyl-l-tartaric anhydride followed by ultra-high performance liquid chromatography-quadrupole-time-of-flight mass spectrometry.

    PubMed

    Zhao, Jing; Shin, Yujin; Jin, Yan; Jeong, Kyung Min; Lee, Jeongmi

    2017-01-01

    Vigabatrin, one of the most widely used antiepileptic drugs, is marketed and administered as a racemic mixture, while only S-enantiomer is therapeutically effective. In the present study, diacetyl-l-tartaric acid anhydride was used as an inexpensive and effective chiral derivatization reagent to produce tartaric acid monoester derivatives of vigabatrin enantiomers that could be readily resolved by reversed phase chromatography. Derivatization conditions were statistically optimized by response surface methodology, resulting in an optimal reaction temperature of 44°C and an optimal reaction time of 30min. The derivatized diastereomers of vigabatrin and internal standard (gabapentin) were analyzed using ultra-high performance liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry. For this analysis, an Agilent ZORBAX Rapid Resolution High Definition Eclipse Plus C18 column (100mm×2.1mm, 1.8μm) was employed for chromatographic separation using 10mM ammonium formate (pH 3.0) and methanol as mobile phase at a flow rate of 0.2mLmin -1 . The established method was validated in terms of specificity, linearity, precision, accuracy, dilution integrity, recovery, matrix effect, stability, and incurred sample reanalysis. It was linear over a range of 0.25-100.0mgL -1 for both S- and R-enantiomers (R 2 ≥0.9987 for both). Intra- and inter-day precisions and accuracies were within acceptable ranges. The method was successfully applied to determine the levels of vigabatrin enantiomers in mouse serum after administration of vigabatrin racemate. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Quantification of strontium in human serum by ICP-MS using alternate analyte-free matrix and its application to a pilot bioequivalence study of two strontium ranelate oral formulations in healthy Chinese subjects.

    PubMed

    Zhang, Dan; Wang, Xiaolin; Liu, Man; Zhang, Lina; Deng, Ming; Liu, Huichen

    2015-01-01

    A rapid, sensitive and accurate ICP-MS method using alternate analyte-free matrix for calibration standards preparation and a rapid direct dilution procedure for sample preparation was developed and validated for the quantification of exogenous strontium (Sr) from the drug in human serum. Serum was prepared by direct dilution (1:29, v/v) in an acidic solution consisting of nitric acid (0.1%) and germanium (Ge) added as internal standard (IS), to obtain simple and high-throughput preparation procedure with minimized matrix effect, and good repeatability. ICP-MS analysis was performed using collision cell technology (CCT) mode. Alternate matrix method by using distilled water as an alternate analyte-free matrix for the preparation of calibration standards (CS) was used to avoid the influence of endogenous Sr in serum on the quantification. The method was validated in terms of selectivity, carry-over, matrix effects, lower limit of quantification (LLOQ), linearity, precision and accuracy, and stability. Instrumental linearity was verified in the range of 1.00-500ng/mL, corresponding to a concentration range of 0.0300-15.0μg/mL in 50μL sample of serum matrix and alternate matrix. Intra- and inter-day precision as relative standard deviation (RSD) were less than 8.0% and accuracy as relative error (RE) was within ±3.0%. The method allowed a high sample throughput, and was sensitive and accurate enough for a pilot bioequivalence study in healthy male Chinese subjects following single oral administration of two strontium ranelate formulations containing 2g strontium ranelate. Copyright © 2014 Elsevier GmbH. All rights reserved.

  4. Performance evaluation of the QIAGEN EZ1 DSP Virus Kit with Abbott RealTime HIV-1, HBV and HCV assays.

    PubMed

    Schneider, George J; Kuper, Kevin G; Abravaya, Klara; Mullen, Carolyn R; Schmidt, Marion; Bunse-Grassmann, Astrid; Sprenger-Haussels, Markus

    2009-04-01

    Automated sample preparation systems must meet the demands of routine diagnostics laboratories with regard to performance characteristics and compatibility with downstream assays. In this study, the performance of QIAGEN EZ1 DSP Virus Kit on the BioRobot EZ1 DSP was evaluated in combination with the Abbott RealTime HIV-1, HCV, and HBV assays, followed by thermalcycling and detection on the Abbott m2000rt platform. The following performance characteristics were evaluated: linear range and precision, sensitivity, cross-contamination, effects of interfering substances and correlation. Linearity was observed within the tested ranges (for HIV-1: 2.0-6.0 log copies/ml, HCV: 1.3-6.9 log IU/ml, HBV: 1.6-7.6 log copies/ml). Excellent precision was obtained (inter-assay standard deviation for HIV-1: 0.06-0.17 log copies/ml (>2.17 log copies/ml), HCV: 0.05-0.11 log IU/ml (>2.09 log IU/ml), HBV: 0.03-0.07 log copies/ml (>2.55 log copies/ml)), with good sensitivity (95% hit rates for HIV-1: 50 copies/ml, HCV: 12.5 IU/ml, HBV: 10 IU/ml). No cross-contamination was observed, as well as no negative impact of elevated levels of various interfering substances. In addition, HCV and HBV viral load measurements after BioRobot EZ1 DSP extraction correlated well with those obtained after Abbott m2000sp extraction. This evaluation demonstrates that the QIAGEN EZ1 DSP Virus Kit provides an attractive solution for fully automated, low throughput sample preparation for use with the Abbott RealTime HIV-1, HCV, and HBV assays.

  5. Development and validation of a UPLC method for the determination of duloxetine hydrochloride residues on pharmaceutical manufacturing equipment surfaces

    PubMed Central

    Kumar, Navneet; Sangeetha, D.; Balakrishna, P.

    2011-01-01

    Background: In pharmaceutical industries, it is very important to remove drug residues from the equipment and areas used. The cleaning procedure must be validated, so special attention must be devoted to the methods used for analysis of trace amounts of drugs. A rapid, sensitive, and specific reverse phase ultra-performance liquid chromatographic (UPLC) method was developed for the quantitative determination of duloxetine in cleaning validation swab samples. Material and Methods: The method was validated using an Acquity UPLC™ HSS T3 (100 × 2.1 mm2) 1.8 μm column with a isocratic mobile phase containing a mixture of 0.01 M potassium dihydrogen orthophosphate, pH adjusted to 3.0 with orthophosphoric acid and acetonitrile (60:40 v/v). The flow rate of the mobile phase was 0.4 ml/min with a column temperature of 40°C and detection wavelength at 230 nm. Cotton swabs, moisten with extraction solution (90% methanol and 10% water), were used to remove any residue of drug from stainless steel, glass and silica surfaces, and give recoveries >80% at four concentration levels. Results: The precision of the results, reported as the relative standard deviation, were below 1.5%. The calibration curve was linear over a concentration range from 0.02 to 5.0 μg/ml with a correlation coefficient of 0.999. The detection limit and quantitation limit were 0.006 and 0.02 μg/ml, respectively. The method was validated over a concentration range of 0.05–5.0 μg/ml. Conclusion: The developed method was validated with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness. PMID:23781449

  6. Development and Validation of Chemometric Spectrophotometric Methods for Simultaneous Determination of Simvastatin and Nicotinic Acid in Binary Combinations.

    PubMed

    Alahmad, Shoeb; Elfatatry, Hamed M; Mabrouk, Mokhtar M; Hammad, Sherin F; Mansour, Fotouh R

    2018-01-01

    The development and introduction of combined therapy represent a challenge for analysis due to severe overlapping of their UV spectra in case of spectroscopy or the requirement of a long tedious and high cost separation technique in case of chromatography. Quality control laboratories have to develop and validate suitable analytical procedures in order to assay such multi component preparations. New spectrophotometric methods for the simultaneous determination of simvastatin (SIM) and nicotinic acid (NIA) in binary combinations were developed. These methods are based on chemometric treatment of data, the applied chemometric techniques are multivariate methods including classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS). In these techniques, the concentration data matrix were prepared by using the synthetic mixtures containing SIM and NIA dissolved in ethanol. The absorbance data matrix corresponding to the concentration data matrix was obtained by measuring the absorbance at 12 wavelengths in the range 216 - 240 nm at 2 nm intervals in the zero-order. The spectrophotometric procedures do not require any separation step. The accuracy, precision and the linearity ranges of the methods have been determined and validated by analyzing synthetic mixtures containing the studied drugs. Chemometric spectrophotometric methods have been developed in the present study for the simultaneous determination of simvastatin and nicotinic acid in their synthetic binary mixtures and in their mixtures with possible excipients present in tablet dosage form. The validation was performed successfully. The developed methods have been shown to be accurate, linear, precise, and so simple. The developed methods can be used routinely for the determination dosage form. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Development & validation of a quantitative anti-protective antigen IgG enzyme linked immunosorbent assay for serodiagnosis of cutaneous anthrax.

    PubMed

    Ghosh, N; Gunti, D; Lukka, H; Reddy, B R; Padmaja, Jyothi; Goel, A K

    2015-08-01

    Anthrax caused by Bacillus anthracis is primarily a disease of herbivorous animals, although several mammals are vulnerable to it. ELISA is the most widely accepted serodiagnostic assay for large scale surveillance of cutaneous anthrax. The aims of this study were to develop and evaluate a quantitative ELISA for determination of IgG antibodies against B. anthracis protective antigen (PA) in human cutaneous anthrax cases. Quantitative ELISA was developed using the recombinant PA for coating and standard reference serum AVR801 for quantification. A total of 116 human test and control serum samples were used in the study. The assay was evaluated for its precision, accuracy and linearity. The minimum detection limit and lower limit of quantification of the assay for anti-PA IgG were 3.2 and 4 µg/ml, respectively. The serum samples collected from the anthrax infected patients were found to have anti-PA IgG concentrations of 5.2 to 166.3 µg/ml. The intra-assay precision per cent CV within an assay and within an operator ranged from 0.99 to 7.4 per cent and 1.7 to 3.9 per cent, respectively. The accuracy of the assay was high with a per cent error of 6.5 - 24.1 per cent. The described assay was found to be linear between the range of 4 to 80 ng/ml (R [2] = 0.9982; slope = 0.9186; intercept = 0.1108). The results suggested that the developed assay could be a useful tool for quantification of anti-PA IgG response in human after anthrax infection or vaccination.

  8. Determination of Residual Solvents in Linezolid by Static Headspace GC

    PubMed Central

    Feng, Xiao-Zhen; Han, Guo-Cheng; Qin, Jianhe; Yin, Shi-min; Chen, Zhencheng

    2016-01-01

    A headspace gas chromatographic method was developed for the determination of residual solvents in linezolid active substances. The solvents include petroleum ether (60–90°C), acetone, tetrahydrofuran, ethyl acetate, methanol, dichloromethane (DCM) and pyridine. The method showed the possibility to detect the tested solvents with a linear determination correlation coefficient (r) greater than 0.9995 except for petroleum ether (0.9980). The limits of detection ranged between 0.12 μg/mL (petroleum ether) and 3.56 μg/mL (DCM), and the limits of quantity ranged between 0.41 μg/mL (petroleum ether) and 11.86 μg/mL (DCM). The method achieved good accuracy (recoveries ranging from 92.8 to 102.5%) and precision for both run-to-run and day-to-day assay (relative standard deviation ranging from 0.4 to 1.3%) for all seven solvents concerned, which were applied in the quality control of three batches of linezolid successfully. PMID:26657409

  9. Method validation using weighted linear regression models for quantification of UV filters in water samples.

    PubMed

    da Silva, Claudia Pereira; Emídio, Elissandro Soares; de Marchi, Mary Rosa Rodrigues

    2015-01-01

    This paper describes the validation of a method consisting of solid-phase extraction followed by gas chromatography-tandem mass spectrometry for the analysis of the ultraviolet (UV) filters benzophenone-3, ethylhexyl salicylate, ethylhexyl methoxycinnamate and octocrylene. The method validation criteria included evaluation of selectivity, analytical curve, trueness, precision, limits of detection and limits of quantification. The non-weighted linear regression model has traditionally been used for calibration, but it is not necessarily the optimal model in all cases. Because the assumption of homoscedasticity was not met for the analytical data in this work, a weighted least squares linear regression was used for the calibration method. The evaluated analytical parameters were satisfactory for the analytes and showed recoveries at four fortification levels between 62% and 107%, with relative standard deviations less than 14%. The detection limits ranged from 7.6 to 24.1 ng L(-1). The proposed method was used to determine the amount of UV filters in water samples from water treatment plants in Araraquara and Jau in São Paulo, Brazil. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Development of a real-time, high-frequency ultrasound digital beamformer for high-frequency linear array transducers.

    PubMed

    Hu, Chang-Hong; Xu, Xiao-Chen; Cannata, Jonathan M; Yen, Jesse T; Shung, K Kirk

    2006-02-01

    A real-time digital beamformer for high-frequency (>20 MHz) linear ultrasonic arrays has been developed. The system can handle up to 64-element linear array transducers and excite 16 channels and receive simultaneously at 100 MHz sampling frequency with 8-bit precision. Radio frequency (RF) signals are digitized, delayed, and summed through a real-time digital beamformer, which is implemented using a field programmable gate array (FPGA). Using fractional delay filters, fine delays as small as 2 ns can be implemented. A frame rate of 30 frames per second is achieved. Wire phantom (20 microm tungsten) images were obtained and -6 dB axial and lateral widths were measured. The results showed that, using a 30 MHz, 48-element array with a pitch of 100 microm produced a -6 dB width of 68 microm in the axial and 370 microm in the lateral direction at 6.4 mm range. Images from an excised rabbit eye sample also were acquired, and fine anatomical structures, such as the cornea and lens, were resolved.

  11. THE MIRA–TITAN UNIVERSE: PRECISION PREDICTIONS FOR DARK ENERGY SURVEYS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heitmann, Katrin; Habib, Salman; Biswas, Rahul

    2016-04-01

    Large-scale simulations of cosmic structure formation play an important role in interpreting cosmological observations at high precision. The simulations must cover a parameter range beyond the standard six cosmological parameters and need to be run at high mass and force resolution. A key simulation-based task is the generation of accurate theoretical predictions for observables using a finite number of simulation runs, via the method of emulation. Using a new sampling technique, we explore an eight-dimensional parameter space including massive neutrinos and a variable equation of state of dark energy. We construct trial emulators using two surrogate models (the linear powermore » spectrum and an approximate halo mass function). The new sampling method allows us to build precision emulators from just 26 cosmological models and to systematically increase the emulator accuracy by adding new sets of simulations in a prescribed way. Emulator fidelity can now be continuously improved as new observational data sets become available and higher accuracy is required. Finally, using one ΛCDM cosmology as an example, we study the demands imposed on a simulation campaign to achieve the required statistics and accuracy when building emulators for investigations of dark energy.« less

  12. The mira-titan universe. Precision predictions for dark energy surveys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heitmann, Katrin; Bingham, Derek; Lawrence, Earl

    2016-03-28

    Large-scale simulations of cosmic structure formation play an important role in interpreting cosmological observations at high precision. The simulations must cover a parameter range beyond the standard six cosmological parameters and need to be run at high mass and force resolution. A key simulation-based task is the generation of accurate theoretical predictions for observables using a finite number of simulation runs, via the method of emulation. Using a new sampling technique, we explore an eight-dimensional parameter space including massive neutrinos and a variable equation of state of dark energy. We construct trial emulators using two surrogate models (the linear powermore » spectrum and an approximate halo mass function). The new sampling method allows us to build precision emulators from just 26 cosmological models and to systematically increase the emulator accuracy by adding new sets of simulations in a prescribed way. Emulator fidelity can now be continuously improved as new observational data sets become available and higher accuracy is required. Finally, using one ΛCDM cosmology as an example, we study the demands imposed on a simulation campaign to achieve the required statistics and accuracy when building emulators for investigations of dark energy.« less

  13. A comparative study of smart spectrophotometric methods for simultaneous determination of a skeletal muscle relaxant and an analgesic in combined dosage form.

    PubMed

    Salem, Hesham; Mohamed, Dalia

    2015-04-05

    Six simple, specific, accurate and precise spectrophotometric methods were developed and validated for the simultaneous determination of the analgesic drug; paracetamol (PARA) and the skeletal muscle relaxant; dantrolene sodium (DANT). Three methods are manipulating ratio spectra namely; ratio difference (RD), ratio subtraction (RS) and mean centering (MC). The other three methods are utilizing the isoabsorptive point either at zero order namely; absorbance ratio (AR) and absorbance subtraction (AS) or at ratio spectrum namely; amplitude modulation (AM). The proposed spectrophotometric procedures do not require any preliminary separation step. The accuracy, precision and linearity ranges of the proposed methods were determined. The selectivity of the developed methods was investigated by analyzing laboratory prepared mixtures of the drugs and their combined dosage form. Standard deviation values are less than 1.5 in the assay of raw materials and capsules. The obtained results were statistically compared with each other and with those of reported spectrophotometric ones. The comparison showed that there is no significant difference between the proposed methods and the reported methods regarding both accuracy and precision. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Multimycotoxin LC-MS/MS Analysis in Tea Beverages after Dispersive Liquid-Liquid Microextraction (DLLME).

    PubMed

    Pallarés, Noelia; Font, Guillermina; Mañes, Jordi; Ferrer, Emilia

    2017-11-29

    The aim of the present study was to develop a multimycotoxin liquid chromatography tandem mass spectrometry (LC-MS/MS) method with a dispersive liquid-liquid microextraction procedure (DLLME) for the analysis of AFs, 3aDON, 15aDON, NIV, HT-2, T-2, ZEA, OTA, ENNs, and BEA in tea beverages and to evaluate their mycotoxin contents. The proposed method was characterized in terms of linearity, limits of detection (LODs), limits of quantification (LOQs), recoveries, repeatability (intraday precision), reproducibility (interday precision), and matrix effects to check suitability. The results show LODs in the range of 0.05-10 μg/L, LOQs in the range of 0.2-33 μg/L, and recoveries in the range of 65-127% (RSD < 20%). The method developed in this study was applied to 44 commercial samples of black tea, red tea, green tea, and green mint tea. The results show that, of the analyzed mycotoxins, AFB2, AFG2, 15aDON, AFG1, and ENB were detected in the samples. AFB2 (14.4-32.2 μg/L) and 15aDON (60.5-61 μg/L) presented the highest levels. Green mint tea contained the highest concentration of mycotoxins. The risk assessment study shows that the population is not much exposed to mycotoxins through the consumption of tea beverages.

  15. Validated high-performance liquid chromatographic method utilizing solid-phase extraction for the simultaneous determination of naringenin and hesperetin in human plasma.

    PubMed

    Kanaze, Feras Imad; Kokkalou, Eugene; Georgarakis, Manolis; Niopas, Ioannis

    2004-03-05

    Naringenin and hesperetin, the aglycones of the flavanone glucosides naringin and hesperidin occur naturally in citrus fruits. They exert a variety of pharmacological effects such as antioxidant, blood lipid-lowering, anticarcinogenic and inhibit selected cytochrome P-450 enzymes resulting in drug interactions. A specific, sensitive, precise, and accurate solid-phase extraction high-performance liquid chromatographic (HPLC) assay for the simultaneous determination of naringenin and hesperetin in human plasma was developed and validated. After addition of 7-ethoxycoumarin as internal standard, plasma samples were incubated with beta-glucuronidase/sulphatase, and the analytes were isolated from plasma by solid-phase extraction using C(18) cartridges and separated on a C(8) reversed phase column with methanol/water/acetic acid (40:58:2, v/v/v) as the eluent at 45 degrees C. The method was linear in the 10-300 ng/ml concentration range for both naringenin and hesperetin (r>0.999). Recovery for naringenin, hesperetin and internal standard was greater than 76.7%. Intra- and inter-day precision for naringenin ranged from 1.4 to 4.2% and from 1.9 to 5.2%, respectively, and for hesperetin ranged from 1.3 to 4.1% and from 1.7 to 5.1%, respectively. Accuracy was better than 91.5 and 91.3% for naringenin and hesperetin, respectively.

  16. Five degree-of-freedom control of an ultra-precision magnetically-suspended linear bearing. Ph.D. Thesis - MIT

    NASA Technical Reports Server (NTRS)

    Trumper, David L.; Slocum, A. H.

    1991-01-01

    The authors constructed a high precision linear bearing. A 10.7 kg platen measuring 125 mm by 125 mm by 350 mm is suspended and controlled in five degrees of freedom by seven electromagnets. The position of the platen is measured by five capacitive probes which have nanometer resolution. The suspension acts as a linear bearing, allowing linear travel of 50 mm in the sixth degree of freedom. In the laboratory, this bearing system has demonstrated position stability of 5 nm peak-to-peak. This is believed to be the highest position stability yet demonstrated in a magnetic suspension system. Performance at this level confirms that magnetic suspensions can address motion control requirements at the nanometer level. The experimental effort associated with this linear bearing system is described. Major topics are the development of models for the suspension, implementation of control algorithms, and measurement of the actual bearing performance. Suggestions for the future improvement of the bearing system are given.

  17. Precision of dehydroascorbic acid quantitation with the use of the subtraction method--validation of HPLC-DAD method for determination of total vitamin C in food.

    PubMed

    Mazurek, Artur; Jamroz, Jerzy

    2015-04-15

    In food analysis, a method for determination of vitamin C should enable measuring of total content of ascorbic acid (AA) and dehydroascorbic acid (DHAA) because both chemical forms exhibit biological activity. The aim of the work was to confirm applicability of HPLC-DAD method for analysis of total content of vitamin C (TC) and ascorbic acid in various types of food by determination of validation parameters such as: selectivity, precision, accuracy, linearity and limits of detection and quantitation. The results showed that the method applied for determination of TC and AA was selective, linear and precise. Precision of DHAA determination by the subtraction method was also evaluated. It was revealed that the results of DHAA determination obtained by the subtraction method were not precise which resulted directly from the assumption of this method and the principles of uncertainty propagation. The proposed chromatographic method should be recommended for routine determinations of total vitamin C in various food. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Portable Linear Sled (PLS) for biomedical research

    NASA Technical Reports Server (NTRS)

    Vallotton, Will; Matsuhiro, Dennis; Wynn, Tom; Temple, John

    1993-01-01

    The PLS is a portable linear motion generating device conceived by researchers at Ames Research Center's Vestibular Research Facility and designed by engineers at Ames for the study of motion sickness in space. It is an extremely smooth apparatus, powered by linear motors and suspended on air bearings which ride on precision ground ceramic ways.

  19. Lack of transferability between two automated immunoassays for serum IGF-I measurement.

    PubMed

    Gomez-Gomez, Carolina; Iglesias, Eva M; Barallat, Jaume; Moreno, Fernando; Biosca, Carme; Pastor, Mari-Cruz; Granada, Maria-Luisa

    2014-01-01

    IGF-I is a clinically relevant protein in the diagnosis and monitoring of treatment of growth disor- ders. The Growth Hormone Research Society and the International IGF Research Society have encouraged the adoption of a universal calibration for immunoassays to improve standardization of IGF-I measurements, but currently commercial assays are calibrated either against the old WHO IRR 87/518 or the new WHO 02/254. We compared two IGF-I immunochemiluminescent assays: IMMULITE® 2000 (Siemens) and LIAISON® (DiaSorin), which differ in their standardization, and verified their precision according to quality specifications based on biological variation and their linear range. 62 patient serum samples were analyzed for both assays and compared according to standards of the Clinical and Laboratory Standards Institute (CLSI), EP9-A2-IR. Precision was verified according to CLSI EP15- A2. Optimal coefficient of variation (CVo) and desirable coefficient of variation (CVd) for IGF-I assays were calculated as quality specifications based on the biological variability, in order to assess if the interassay analytical CV (CVa1) in the two methods were appropriate. Two dilution series using the 1st WHO International Standard (WHO IS) for IGF-I 02/254 were used to verify and compare the linearity range. The regression analysis showed constant and proportional differences for serum samples (slope b = 0.8115 (CI 95% CI; 0.7575-0.8556); intercept a = 33.6873 (95% CI: 23.3613-44.0133) between assays and similar pro- portional differences for WHO IS 02/254 standard dilutions series (slope b = 0.8024 (CI 95% CI; 0.7560-0.8616); intercept a = 6.9623 (95% CI: -2.0819-18.4383) between assays. Within-laboratory coefficients of variation for low and high levels were 2.82% and 3.80% for IMMULITE® 2000 and 3.58% and 2.14% for LIAISON®, respecttively. IGF-I concentrations measured by both assays are not transferable. The results emphasize the need to express IGF-I concentrations in standard deviation score (SDS) according to a matched normal population of the same age and gender. Within-laboratory precision in both methods met quality specifications derived from biological variation.

  20. Combining simplicity with cost-effectiveness: Investigation of potential counterfeit of proton pump inhibitors through simulated formulations using thin-layer chromatography.

    PubMed

    Bhatt, Nejal M; Chavada, Vijay D; Sanyal, Mallika; Shrivastav, Pranav S

    2016-11-18

    A simple, accurate and precise high-performance thin-layer chromatographic method has been developed and validated for the analysis of proton pump inhibitors (PPIs) and their co-formulated drugs, available as binary combination. Planar chromatographic separation was achieved using a single mobile phase comprising of toluene: iso-propranol: acetone: ammonia 5.0:2.3:2.5:0.2 (v/v/v/v) for the analysis of 14 analytes on aluminium-backed layer of silica gel 60 FG 254 . Densitometric determination of the separated spots was done at 290nm. The method was validated according to ICH guidelines for linearity, precision and accuracy, sensitivity, specificity and robustness. The method showed good linear response for the selected drugs as indicated by the high values of correlation coefficients (≥0.9993). The limit of detection and limit of quantiation were in the range of 6.9-159.2ng/band and 20.8-478.1ng/band respectively for all the analytes. The optimized conditions afforded adequate resolution of each PPI from their co-formulated drugs and provided unambiguous identification of the co-formulated drugs from their homologous retardation factors (hR f ). The only limitation of the method was the inability to separate two PPIs, rabeprazole and lansoprazole from each other. Nevertheless, it is proposed that peak spectra recording and comparison with standard drug spot can be a viable option for assignment of TLC spots. The method performance was assessed by analyzing different laboratory simulated mixtures and some marketed formulations of the selected drugs. The developed method was successfully used to investigate potential counterfeit of PPIs through a series of simulated formulations with good accuracy and precision. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Measurement of atmospheric ozone by cavity ring-down spectroscopy.

    PubMed

    Washenfelder, R A; Wagner, N L; Dube, W P; Brown, S S

    2011-04-01

    Ozone plays a key role in both the Earth's radiative budget and photochemistry. Accurate, robust analytical techniques for measuring its atmospheric abundance are of critical importance. Cavity ring-down spectroscopy has been successfully used for sensitive and accurate measurements of many atmospheric species. However, this technique has not been used for atmospheric measurements of ozone, because the strongest ozone absorption bands occur in the ultraviolet spectral region, where Rayleigh and Mie scattering cause significant cavity losses and dielectric mirror reflectivities are limited. Here, we describe a compact instrument that measures O3 by chemical conversion to NO2 in excess NO, with subsequent detection by cavity ring-down spectroscopy. This method provides a simple, accurate, and high-precision measurement of atmospheric ozone. The instrument consists of two channels. The sum of NO2 and converted O3 (defined as Ox) is measured in the first channel, while NO2 alone is measured in the second channel. NO2 is directly detected in each channel by cavity ring-down spectroscopy with a laser diode light source at 404 nm. The limit of detection for O3 is 26 pptv (2 sigma precision) at 1 s time resolution. The accuracy of the measurement is ±2.2%, with the largest uncertainty being the effective NO2 absorption cross-section. The linear dynamic range of the instrument has been verified from the detection limit to above 200 ppbv (r2>99.99%). The observed precision on signal (2 sigma) with 41 ppbv O3 is 130 pptv in 1 s. Comparison of this instrument to UV absorbance instruments for ambient O3 concentrations shows linear agreement (r2=99.1%) with slope of 1.012±0.002.

  2. Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy.

    PubMed

    Low, D A; Sohn, J W; Klein, E E; Markman, J; Mutic, S; Dempsey, J F

    2001-05-01

    The characteristics of a commercial multileaf collimator (MLC) to deliver static and dynamic multileaf collimation (SMLC and DMLC, respectively) were investigated to determine their influence on intensity modulated radiation therapy (IMRT) treatment planning and quality assurance. The influence of MLC leaf positioning accuracy on sequentially abutted SMLC fields was measured by creating abutting fields with selected gaps and overlaps. These data were also used to measure static leaf positioning precision. The characteristics of high leaf-velocity DMLC delivery were measured with constant velocity leaf sequences starting with an open field and closing a single leaf bank. A range of 1-72 monitor units (MU) was used providing a range of leaf velocities. The field abutment measurements yielded dose errors (as a percentage of the open field max dose) of 16.7+/-0.7% mm(-1) and 12.8+/-0.7% mm(-1) for 6 MV and 18 MV photon beams, respectively. The MLC leaf positioning precision was 0.080+/-0.018 mm (single standard deviation) highlighting the excellent delivery hardware tolerances for the tested beam delivery geometry. The high leaf-velocity DMLC measurements showed delivery artifacts when the leaf sequence and selected monitor units caused the linear accelerator to move the leaves at their maximum velocity while modulating the accelerator dose rate to deliver the desired leaf and MU sequence (termed leaf-velocity limited delivery). According to the vendor, a unique feature to their linear accelerator and MLC is that the dose rate is reduced to provide the correct cm MU(-1) leaf velocity when the delivery is leaf-velocity limited. However, it was found that the system delivered roughly 1 MU per pulse when the delivery was leaf-velocity limited causing dose profiles to exhibit discrete steps rather than a smooth dose gradient. The root mean square difference between the steps and desired linear gradient was less than 3% when more than 4 MU were used. The average dose per MU was greater and less than desired for closing and opening leaf patterns, respectively, when the delivery was leaf-velocity limited. The results indicated that the dose delivery artifacts should be minor for most clinical cases, but limit the assumption of dose linearity when significantly reducing the delivered dose for dosimeter characterization studies or QA measurements.

  3. Mechanical design of a precision linear flexural stage for 3D x-ray diffraction microscope at the Advanced Photon Source

    NASA Astrophysics Data System (ADS)

    Shu, D.; Liu, W.; Kearney, S.; Anton, J.; Tischler, J. Z.

    2015-09-01

    The 3-D X-ray diffraction microscope is a new nondestructive tool for the three-dimensional characterization of mesoscopic materials structure. A flexural-pivot-based precision linear stage has been designed to perform a wire scan as a differential aperture for the 3-D diffraction microscope at the Advanced Photon Source, Argonne National Laboratory. The mechanical design and finite element analyses of the flexural stage, as well as its initial mechanical test results with laser interferometer are described in this paper.

  4. Plasma-equivalent glucose at the point-of-care: evaluation of Roche Accu-Chek Inform and Abbott Precision PCx glucose meters.

    PubMed

    Ghys, Timothy; Goedhuys, Wim; Spincemaille, Katrien; Gorus, Frans; Gerlo, Erik

    2007-01-01

    Glucose testing at the bedside has become an integral part of the management strategy in diabetes and of the careful maintenance of normoglycemia in all patients in intensive care units. We evaluated two point-of-care glucometers for the determination of plasma-equivalent blood glucose. The Precision PCx and the Accu-Chek Inform glucometers were evaluated. Imprecision and bias relative to the Vitros 950 system were determined using protocols of the Clinical Laboratory Standards Institute (CLSI). The effects of low, normal, and high hematocrit levels were investigated. Interference by maltose was also studied. Within-run precision for both instruments ranged from 2-5%. Total imprecision was less than 5% except for the Accu-Chek Inform at the low level (2.9 mmol/L). Both instruments correlated well with the comparison instrument and showed excellent recovery and linearity. Both systems reported at least 95% of their values within zone A of the Clarke Error Grid, and both fulfilled the CLSI quality criteria. The more stringent goals of the American Diabetes Association, however, were not reached. Both systems showed negative bias at high hematocrit levels. Maltose interfered with the glucose measurements on the Accu-Chek Inform but not on the Precision PCx. Both systems showed satisfactory imprecision and were reliable in reporting plasma-equivalent glucose concentrations. The most stringent performance goals were however not met.

  5. Trueness, Precision, and Detectability for Sampling and Analysis of Organic Species in Airborne Particulate Matter

    EPA Science Inventory

    Recovery. precision, limits of detection and quantitation, blank levels, calibration linearity, and agreement with certified reference materials were determined for two classes of organic components of airborne particulate matter, polycyclic aromatic hydrocarbons and hopanes usin...

  6. Cumulative detection probabilities and range accuracy of a pulsed Geiger-mode avalanche photodiode laser ranging system

    NASA Astrophysics Data System (ADS)

    Luo, Hanjun; Ouyang, Zhengbiao; Liu, Qiang; Chen, Zhiliang; Lu, Hualan

    2017-10-01

    Cumulative pulses detection with appropriate cumulative pulses number and threshold has the ability to improve the detection performance of the pulsed laser ranging system with GM-APD. In this paper, based on Poisson statistics and multi-pulses cumulative process, the cumulative detection probabilities and their influence factors are investigated. With the normalized probability distribution of each time bin, the theoretical model of the range accuracy and precision is established, and the factors limiting the range accuracy and precision are discussed. The results show that the cumulative pulses detection can produce higher target detection probability and lower false alarm probability. However, for a heavy noise level and extremely weak echo intensity, the false alarm suppression performance of the cumulative pulses detection deteriorates quickly. The range accuracy and precision is another important parameter evaluating the detection performance, the echo intensity and pulse width are main influence factors on the range accuracy and precision, and higher range accuracy and precision is acquired with stronger echo intensity and narrower echo pulse width, for 5-ns echo pulse width, when the echo intensity is larger than 10, the range accuracy and precision lower than 7.5 cm can be achieved.

  7. SPM interferometer with large range for mirco-vibration measurement

    NASA Astrophysics Data System (ADS)

    Fu, Mingyi; Tang, Chaowei; He, Guotian; Hu, Jun; Wang, Li

    2007-12-01

    The measuring range and precision are two inconsistent parameters of traditional optical interferometry. In this paper, the interferometer measuring vibration with high precision and large range is proposed and its measuring principle is analyzed in detail. The interferometer obtains phase information by processing interference signals with two real-time phase discriminator and the vibration displacement could be gotten by expanding this phase. The measuring range was enlarged from half wavelength to millimeter. Meanwhile, the measuring precision was independent of external disturbance and vibration displacement measurement with high precision was realized. The measuring range of vibration displacement for 6000.5nm and the repeatable measuring precision was 5.72nm from experiment. The feasibility of the measuring method was validated by experiments.

  8. Simultaneous determination of atenolol, chlorthalidone and amiloride in pharmaceutical preparations by capillary zone electrophoresis with ultraviolet detection.

    PubMed

    Al Azzam, Khaldun M; Saad, Bahruddin; Aboul-Enein, Hassan Y

    2010-09-01

    Capillary zone electrophoresis methods for the simultaneous determination of the beta-blocker drugs, atenolol, chlorthalidone and amiloride, in pharmaceutical formulations have been developed. The influences of several factors (buffer pH, concentration, applied voltage, capillary temperature and injection time) were studied. Using phenobarbital as internal standard, the analytes were all separated in less than 4 min. The separation was carried out in normal polarity mode at 25 degrees C, 25 kV and using hydrodynamic injection (10 s). The separation was effected in an uncoated fused-silica capillary (75 mum i.d. x 52 cm) and a background electrolyte of 25 mm H(3)PO(4) adjusted with 1 m NaOH solution (pH 9.0) and detection at 198 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 1-250 microg/mL for atenolol and chlorthalidone and from 2.5-250 microg/mL for amiloride. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol, chlorthalidone and amiloride in various pharmaceutical tablets formulations. 2010 John Wiley & Sons, Ltd.

  9. Ariadne's Thread: A Robust Software Solution Leading to Automated Absolute and Relative Quantification of SRM Data.

    PubMed

    Nasso, Sara; Goetze, Sandra; Martens, Lennart

    2015-09-04

    Selected reaction monitoring (SRM) MS is a highly selective and sensitive technique to quantify protein abundances in complex biological samples. To enhance the pace of SRM large studies, a validated, robust method to fully automate absolute quantification and to substitute for interactive evaluation would be valuable. To address this demand, we present Ariadne, a Matlab software. To quantify monitored targets, Ariadne exploits metadata imported from the transition lists, and targets can be filtered according to mProphet output. Signal processing and statistical learning approaches are combined to compute peptide quantifications. To robustly estimate absolute abundances, the external calibration curve method is applied, ensuring linearity over the measured dynamic range. Ariadne was benchmarked against mProphet and Skyline by comparing its quantification performance on three different dilution series, featuring either noisy/smooth traces without background or smooth traces with complex background. Results, evaluated as efficiency, linearity, accuracy, and precision of quantification, showed that Ariadne's performance is independent of data smoothness and complex background presence and that Ariadne outperforms mProphet on the noisier data set and improved 2-fold Skyline's accuracy and precision for the lowest abundant dilution with complex background. Remarkably, Ariadne could statistically distinguish from each other all different abundances, discriminating dilutions as low as 0.1 and 0.2 fmol. These results suggest that Ariadne offers reliable and automated analysis of large-scale SRM differential expression studies.

  10. Electron kinetic effects on optical diagnostics in fusion plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mirnov, V. V.; Den Hartog, D. J.; Duff, J.

    At anticipated high electron temperatures in ITER, the effects of electron thermal motion on Thomson scattering (TS), toroidal interferometer/polarimeter (TIP) and poloidal polarimeter (PoPola) diagnostics will be significant and must be accurately treated. We calculate electron thermal corrections to the interferometric phase and polarization state of an EM wave propagating along tangential and poloidal chords (Faraday and Cotton-Mouton polarimetry) and perform analysis of the degree of polarization for incoherent TS. The precision of the previous lowest order linear in τ = T{sub e}/m{sub e}c{sup 2} model may be insufficient; we present a more precise model with τ{sup 2}-order corrections to satisfy themore » high accuracy required for ITER TIP and PoPola diagnostics. The linear model is extended from Maxwellian to a more general class of anisotropic electron distributions that allows us to take into account distortions caused by equilibrium current, ECRH and RF current drive effects. The classical problem of degree of polarization of incoherent Thomson scattered radiation is solved analytically exactly without any approximations for the full range of incident polarizations, scattering angles, and electron thermal motion from non-relativistic to ultra-relativistic. The results are discussed in the context of the possible use of the polarization properties of Thomson scattered light as a method of T{sup e} measurement relevant to ITER operational scenarios.« less

  11. Stability of suxamethonium in pharmaceutical solution for injection by validated stability-indicating chromatographic method.

    PubMed

    Beck, William; Kabiche, Sofiane; Balde, Issa-Bella; Carret, Sandra; Fontan, Jean-Eudes; Cisternino, Salvatore; Schlatter, Joël

    2016-12-01

    To assess the stability of pharmaceutical suxamethonium (succinylcholine) solution for injection by validated stability-indicating chromatographic method in vials stored at room temperature. The chromatographic assay was achieved by using a detector wavelength set at 218 nm, a C18 column, and an isocratic mobile phase (100% of water) at a flow rate of 0.6 mL/min for 5 minutes. The method was validated according to the International Conference on Harmonization guidelines with respect to the stability-indicating capacity of the method including linearity, limits of detection and quantitation, precision, accuracy, system suitability, robustness, and forced degradations. Linearity was achieved in the concentration range of 5 to 40 mg/mL with a correlation coefficient higher than 0.999. The limits of detection and quantification were 0.8 and 0.9 mg/mL, respectively. The percentage relative standard deviation for intraday (1.3-1.7) and interday (0.1-2.0) precision was found to be less than 2.1%. Accuracy was assessed by the recovery test of suxamethonium from solution for injection (99.5%-101.2%). Storage of suxamethonium solution for injection vials at ambient temperature (22°C-26°C) for 17 days demonstrated that at least 95% of original suxamethonium concentration remained stable. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Simultaneous Determination of Clidinium Bromide and Chlordiazepoxide in Combined Dosage Forms by High-Performance Liquid Chromatography.

    PubMed

    Ashour, Safwan; Kattan, Nuha

    2013-01-01

    A sensitive and precise RP-HPLC method has been developed for the simultaneous estimation of clidinium bromide (CDB) and chlordiazepoxide (CDZ) in pure and pharmaceutical formulations. The separation was achieved on a Nucleodur C8 (250 × 4.6 mm i.d., 5 μm particle size) column at 25°C. CH3CN-MeOH-NH4OAc 0.1M (30 : 40 : 30, v/v/v) was used as the mobile phase at a flow rate of 1.0 mL min(-1) and detector wavelength at 218 nm. Almotriptan (ALT) was used as internal standard. The validation of the proposed method was carried out for linearity, accuracy, precision, LOD, LOQ, and robustness. The method showed good linearity in the ranges of 2.5-300.0 and 3.0-500.0 μg mL(-1) for CDB and CDZ, respectively. The percentage recovery obtained for CDB and CDZ was 100.40-103.38 and 99.98-105.59%, respectively. LOD and LOQ were 0.088 and 0.294 μg mL(-1) for CDB and 0.121 and 0.403 μg mL(-1) for CDZ, respectively. The proposed method was successfully applied to the determination of CDB and CDZ in combined dosage forms and the results tallied well with the label claim.

  13. Development and validation of a reversed-phase high-performance thin-layer chromatography-densitometric method for determination of atorvastatin calcium in bulk drug and tablets.

    PubMed

    Shirkhedkar, Atul A; Surana, Sanjay J

    2010-01-01

    Atorvastatin calcium is a synthetic HMG-CoA reductase inhibitor that is used as a cholesterol-lowering agent. A simple, sensitive, selective, and precise RP-HPTLC-densitometric determination of atorvastatin calcium both as bulk drug and from pharmaceutical formulation was developed and validated according to International Conference on Harmonization guidelines. The method used aluminum sheets precoated with silica gel 60 RP18F254S as the stationary phase, and the mobile phase consisted of methanol-water (3.5 + 1.5, v/v). The system gave a compact band for atorvastatin calcium with an Rf value of 0.62 +/- 0.02. Densitometric quantification was carried out at 246 nm. The linear regression analysis data for the calibration plots showed a good linear relationship with r = 0.9992 in the working concentration range of 100-800 ng/band. The method was validated for precision, accuracy, ruggedness, robustness, specificity, recovery, LOD, and LOQ. The LOD and LOQ were 6 and 18 ng, respectively. The drug underwent hydrolysis when subjected to acidic conditions and was found to be stable under alkali, oxidation, dry heat, and photodegradation conditions. Statistical analysis proved that the developed RP-HPTLC-densitometry method is reproducible and selective and that it can be applied for identification and quantitative determination of atorvastatin calcium in bulk drug and tablet formulation.

  14. Stress Degradation Studies on Varenicline Tartrate and Development of a Validated Stability-Indicating HPLC Method

    PubMed Central

    Pujeri, Sudhakar S.; Khader, Addagadde M. A.; Seetharamappa, Jaldappagari

    2012-01-01

    A simple, rapid and stability-indicating reversed-phase liquid chromatographic method was developed for the assay of varenicline tartrate (VRT) in the presence of its degradation products generated from forced decomposition studies. The HPLC separation was achieved on a C18 Inertsil column (250 mm × 4.6 mm i.d. particle size is 5 μm) employing a mobile phase consisting of ammonium acetate buffer containing trifluoroacetic acid (0.02M; pH 4) and acetonitrile in gradient program mode with a flow rate of 1.0 mL min−1. The UV detector was operated at 237 nm while column temperature was maintained at 40 °C. The developed method was validated as per ICH guidelines with respect to specificity, linearity, precision, accuracy, robustness and limit of quantification. The method was found to be simple, specific, precise and accurate. Selectivity of the proposed method was validated by subjecting the stock solution of VRT to acidic, basic, photolysis, oxidative and thermal degradation. The calibration curve was found to be linear in the concentration range of 0.1–192 μg mL−1 (R2 = 0.9994). The peaks of degradation products did not interfere with that of pure VRT. The utility of the developed method was examined by analyzing the tablets containing VRT. The results of analysis were subjected to statistical analysis. PMID:22396908

  15. Improved sample preparation for GC-MS-SIM analysis of ethyl carbamate in wine.

    PubMed

    Nóbrega, Ian C C; Pereira, Giuliano E; Silva, Marileide; Pereira, Elainy V S; Medeiros, Marcelo M; Telles, Danuza L; Albuquerque, Eden C; Oliveira, Juliane B; Lachenmeier, Dirk W

    2015-06-15

    An improved sample preparation procedure for analysis of carcinogenic ethyl carbamate (EC) in wine by GC-MS-SIM is proposed. Differences over AOAC reference procedure were: (1) use of EC-d5 as internal standard instead of less similar propyl carbamate; (2) extraction by diethyl ether instead of more toxic dichloromethane, and (3) concentration by vacuum automated parallel evaporation instead of more time and work consuming rotary evaporation. Mean recovery was 104.4%, intraday precision was 6.7% (3.4 μg L(-)(1)) and 1.7% (88.5 μg L(-)(1)), regression coefficient was 0.999 in the linear working range of 3-89 μg L(-)(1), and limits of detection and quantification were 0.4 and 1.2 μg L(-)(1). Applicability was demonstrated by analysis (in triplicate) of 5 wine samples. EC concentration ranged from 5.2 ± 0.2 to 29.4 ± 1.5 μg L(-)(1). The analytical method is selective, accurate, repeatable, linear, and has similar method performance as the reference method along with the several mentioned advantages. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Optimized lighting method of applying shaped-function signal for increasing the dynamic range of LED-multispectral imaging system

    NASA Astrophysics Data System (ADS)

    Yang, Xue; Hu, Yajia; Li, Gang; Lin, Ling

    2018-02-01

    This paper proposes an optimized lighting method of applying a shaped-function signal for increasing the dynamic range of light emitting diode (LED)-multispectral imaging system. The optimized lighting method is based on the linear response zone of the analog-to-digital conversion (ADC) and the spectral response of the camera. The auxiliary light at a higher sensitivity-camera area is introduced to increase the A/D quantization levels that are within the linear response zone of ADC and improve the signal-to-noise ratio. The active light is modulated by the shaped-function signal to improve the gray-scale resolution of the image. And the auxiliary light is modulated by the constant intensity signal, which is easy to acquire the images under the active light irradiation. The least square method is employed to precisely extract the desired images. One wavelength in multispectral imaging based on LED illumination was taken as an example. It has been proven by experiments that the gray-scale resolution and the accuracy of information of the images acquired by the proposed method were both significantly improved. The optimum method opens up avenues for the hyperspectral imaging of biological tissue.

  17. Optimized lighting method of applying shaped-function signal for increasing the dynamic range of LED-multispectral imaging system.

    PubMed

    Yang, Xue; Hu, Yajia; Li, Gang; Lin, Ling

    2018-02-01

    This paper proposes an optimized lighting method of applying a shaped-function signal for increasing the dynamic range of light emitting diode (LED)-multispectral imaging system. The optimized lighting method is based on the linear response zone of the analog-to-digital conversion (ADC) and the spectral response of the camera. The auxiliary light at a higher sensitivity-camera area is introduced to increase the A/D quantization levels that are within the linear response zone of ADC and improve the signal-to-noise ratio. The active light is modulated by the shaped-function signal to improve the gray-scale resolution of the image. And the auxiliary light is modulated by the constant intensity signal, which is easy to acquire the images under the active light irradiation. The least square method is employed to precisely extract the desired images. One wavelength in multispectral imaging based on LED illumination was taken as an example. It has been proven by experiments that the gray-scale resolution and the accuracy of information of the images acquired by the proposed method were both significantly improved. The optimum method opens up avenues for the hyperspectral imaging of biological tissue.

  18. Spectrophotometric determination of bacitracin in bulk drug as dabsyl derivative in a range of visible light.

    PubMed

    Krzek, Jan; Piotrowska, Joanna

    2011-01-01

    A fast spectrophotometric method has been developed for bacitracin identification and determination after condensation reaction with dabsyl chloride. In addition, determination of dye stability of sulfonamide derivative and identification of the molar ratio of reagents was done at various time-points. The developed method has a good linearity with very broad spectrum, correlation coefficient of r = 0.9972, good precision (RSD = 1.54 +/- 0.11%), and recovery at three different levels of concentration was found between 98.33% and 103.47%. Usefulness of the method was demonstrated by positive results obtained during determination of bacitracin concentration in bulk drug.

  19. Note: Comparison experimental results of the laser heterodyne interferometer for angle measurement based on the Faraday effect.

    PubMed

    Zhang, Enzheng; Chen, Benyong; Zheng, Hao; Teng, Xueying; Yan, Liping

    2018-04-01

    A laser heterodyne interferometer for angle measurement based on the Faraday effect is proposed. A novel optical configuration, designed by using the orthogonal return method for a linearly polarized beam based on the Faraday effect, guarantees that the measurement beam can return effectively even though an angular reflector has a large lateral displacement movement. The optical configuration and measurement principle are presented in detail. Two verification experiments were performed; the experimental results show that the proposed interferometer can achieve a large lateral displacement tolerance of 7.4 mm and also can realize high precision angle measurement with a large measurement range.

  20. Note: Comparison experimental results of the laser heterodyne interferometer for angle measurement based on the Faraday effect

    NASA Astrophysics Data System (ADS)

    Zhang, Enzheng; Chen, Benyong; Zheng, Hao; Teng, Xueying; Yan, Liping

    2018-04-01

    A laser heterodyne interferometer for angle measurement based on the Faraday effect is proposed. A novel optical configuration, designed by using the orthogonal return method for a linearly polarized beam based on the Faraday effect, guarantees that the measurement beam can return effectively even though an angular reflector has a large lateral displacement movement. The optical configuration and measurement principle are presented in detail. Two verification experiments were performed; the experimental results show that the proposed interferometer can achieve a large lateral displacement tolerance of 7.4 mm and also can realize high precision angle measurement with a large measurement range.

  1. An automated gas chromatography time-of-flight mass spectrometry instrument for the quantitative analysis of halocarbons in air

    NASA Astrophysics Data System (ADS)

    Obersteiner, F.; Bönisch, H.; Engel, A.

    2016-01-01

    We present the characterization and application of a new gas chromatography time-of-flight mass spectrometry instrument (GC-TOFMS) for the quantitative analysis of halocarbons in air samples. The setup comprises three fundamental enhancements compared to our earlier work (Hoker et al., 2015): (1) full automation, (2) a mass resolving power R = m/Δm of the TOFMS (Tofwerk AG, Switzerland) increased up to 4000 and (3) a fully accessible data format of the mass spectrometric data. Automation in combination with the accessible data allowed an in-depth characterization of the instrument. Mass accuracy was found to be approximately 5 ppm in mean after automatic recalibration of the mass axis in each measurement. A TOFMS configuration giving R = 3500 was chosen to provide an R-to-sensitivity ratio suitable for our purpose. Calculated detection limits are as low as a few femtograms by means of the accurate mass information. The precision for substance quantification was 0.15 % at the best for an individual measurement and in general mainly determined by the signal-to-noise ratio of the chromatographic peak. Detector non-linearity was found to be insignificant up to a mixing ratio of roughly 150 ppt at 0.5 L sampled volume. At higher concentrations, non-linearities of a few percent were observed (precision level: 0.2 %) but could be attributed to a potential source within the detection system. A straightforward correction for those non-linearities was applied in data processing, again by exploiting the accurate mass information. Based on the overall characterization results, the GC-TOFMS instrument was found to be very well suited for the task of quantitative halocarbon trace gas observation and a big step forward compared to scanning, quadrupole MS with low mass resolving power and a TOFMS technique reported to be non-linear and restricted by a small dynamical range.

  2. Optical telescope refocussing mechanism concept design on remote sensing satellite

    NASA Astrophysics Data System (ADS)

    Kuo, Jen-Chueh; Ling, Jer

    2017-09-01

    The optical telescope system in remote sensing satellite must be precisely aligned to obtain high quality images during its mission life. In practical, because the telescope mirrors could be misaligned due to launch loads, thermal distortion on supporting structures or hygroscopic distortion effect in some composite materials, the optical telescope system is often equipped with refocussing mechanism to re-align the optical elements while optical element positions are out of range during image acquisition. This paper is to introduce satellite Refocussing mechanism function model design development process and the engineering models. The design concept of the refocussing mechanism can be applied on either cassegrain type telescope or korsch type telescope, and the refocussing mechanism is located at the rear of the secondary mirror in this paper. The purpose to put the refocussing mechanism on the secondary mirror is due to its higher sensitivity on MTF degradation than other optical elements. There are two types of refocussing mechanism model to be introduced: linear type model and rotation type model. For the linear refocussing mechanism function model, the model is composed of ceramic piezoelectric linear step motor, optical rule as well as controller. The secondary mirror is designed to be precisely moved in telescope despace direction through refocussing mechanism. For the rotation refocussing mechanism function model, the model is assembled with two ceramic piezoelectric rotational motors around two orthogonal directions in order to adjust the secondary mirror attitude in tilt angle and yaw angle. From the validation test results, the linear type refocussing mechanism function model can be operated to adjust the secondary mirror position with minimum 500 nm resolution with close loop control. For the rotation type model, the attitude angle of the secondary mirror can be adjusted with the minimum 6 sec of arc resolution and 5°/sec of angle velocity.

  3. A comparative study between three stability indicating spectrophotometric methods for the determination of diatrizoate sodium in presence of its cytotoxic degradation product based on two-wavelength selection

    NASA Astrophysics Data System (ADS)

    Riad, Safaa M.; El-Rahman, Mohamed K. Abd; Fawaz, Esraa M.; Shehata, Mostafa A.

    2015-06-01

    Three sensitive, selective, and precise stability indicating spectrophotometric methods for the determination of the X-ray contrast agent, diatrizoate sodium (DTA) in the presence of its acidic degradation product (highly cytotoxic 3,5-diamino metabolite) and in pharmaceutical formulation, were developed and validated. The first method is ratio difference, the second one is the bivariate method, and the third one is the dual wavelength method. The calibration curves for the three proposed methods are linear over a concentration range of 2-24 μg/mL. The selectivity of the proposed methods was tested using laboratory prepared mixtures. The proposed methods have been successfully applied to the analysis of DTA in pharmaceutical dosage forms without interference from other dosage form additives. The results were statistically compared with the official US pharmacopeial method. No significant difference for either accuracy or precision was observed.

  4. Determination of emamectin benzoate in medicated fish feed: a multisite study.

    PubMed

    Farer, Leslie J

    2005-01-01

    A new method was developed for the quantitation of emamectin benzoate in medicated fish feed at levels between 1 and 30 ppm. The new procedure, based on a previously reported assay, consists of a wet methanolic extraction of ground feed, followed by solid-phase extraction and injection onto a gradient liquid chromatographic system. A multisite study involving 3 laboratories (the developing laboratory and 2 independent laboratories) was performed to evaluate precision, recovery, linearity, and sensitivity. Mean recove;ries for triplicate analyses at 3 levels, performed by 2 analysts per laboratory, were between 89 and 97%, with coefficients of variation ranging from 1.6 to 8.6%. Coefficients of determination (r2) obtained from the plotted data were > or =0.993. The precision of the method, determined from 6 replicate preparations from the same batch of medicated feed assayed in 3 separate trials per laboratory, was between 0.6 and 5.8%. The quantitation limit was established at 0.5 ppm. Specificity and robustness studies were performed by the developing laboratory.

  5. High-precision optical measurements of 13C/12C isotope ratios in organic compounds at natural abundance

    PubMed Central

    Zare, Richard N.; Kuramoto, Douglas S.; Haase, Christa; Tan, Sze M.; Crosson, Eric R.; Saad, Nabil M. R.

    2009-01-01

    A continuous-flow cavity ring-down spectroscopy (CRDS) system integrating a chromatographic separation technique, a catalytic combustor, and an isotopic 13C/12C optical analyzer is described for the isotopic analysis of a mixture of organic compounds. A demonstration of its potential is made for the geochemically important class of short-chain hydrocarbons. The system proved to be linear over a 3-fold injection volume dynamic range with an average precision of 0.95‰ and 0.67‰ for ethane and propane, respectively. The calibrated accuracy for methane, ethane, and propane is within 3‰ of the values determined using isotope ratio mass spectrometry (IRMS), which is the current method of choice for compound-specific isotope analysis. With anticipated improvements, the low-cost, portable, and easy-to-use CRDS-based instrumental setup is poised to evolve into a credible challenge to the high-cost and complex IRMS-based technique. PMID:19564619

  6. Simultaneous determination of diclofenac potassium and methocarbamol in ternary mixture with guaifenesin by reversed phase liquid chromatography.

    PubMed

    Elkady, Ehab F

    2010-09-15

    New, simple, rapid and precise reversed phase liquid chromatographic (RP-LC) method has been developed for the simultaneous determination of diclofenac potassium (DP) and methocarbamol (MT) in ternary mixture with guaifenesin (GF), degradation product of methocarbamol. Chromatographic separation was achieved on a Symmetry Waters C18 column (150 mm x 4. 6mm, 5 microm). Gradient elution based on phosphate buffer pH (8)-acetonitrile at a flow rate of 1 mL min(-1) was applied. The UV detector was operated at 282 nm for DP and 274 nm for MT and GF. Linearity, accuracy and precision were found to be acceptable over the concentration ranges of 0.05-16, 0.5-160 and 0.5-160 microg mL(-1) for DP, MT and GF, respectively. The optimized method proved to be specific, robust and accurate for the quality control of the cited drugs in pharmaceutical preparation. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  7. Offset-frequency locking of extended-cavity diode lasers for precision spectroscopy of water at 1.38 μm.

    PubMed

    Gianfrani, Livio; Castrillo, Antonio; Fasci, Eugenio; Galzerano, Gianluca; Casa, Giovanni; Laporta, Paolo

    2010-10-11

    We describe a continuous-wave diode laser spectrometer for water-vapour precision spectroscopy at 1.38 μm. The spectrometer is based upon the use of a simple scheme for offset-frequency locking of a pair of extended-cavity diode lasers that allows to achieve unprecedented accuracy and reproducibility levels in measuring molecular absorption. When locked to the master laser with an offset frequency of 1.5 GHz, the slave laser exhibits residual frequency fluctuations of 1 kHz over a time interval of 25 minutes, for a 1-s integration time. The slave laser could be continuously tuned up to 3 GHz, the scan showing relative deviations from linearity below the 10{-6} level. Simultaneously, a capture range of the order of 1 GHz was obtained. Quantitative spectroscopy was also demonstrated by accurately determining relevant spectroscopic parameters for the 22,1→22,0line of the H2(18)O v1+v3 band at 1384.6008 nm.

  8. 3D DNA origami as programmable anchoring points for bioreceptors in fiber optic surface plasmon resonance biosensing.

    PubMed

    Daems, Devin; Pfeifer, Wolfgang; Rutten, Iene; Sacca, Barbara; Spasic, Dragana; Lammertyn, Jeroen

    2018-06-27

    Many challenges in biosensing originate from the fact that the all-important nano-architecture of the biosensor's surface, including precise density and orientation of bioreceptors, is not entirely comprehended. Here we introduced a 3D DNA origami as bioreceptor carrier to functionalize the fiber optic surface plasmon resonance (FO-SPR) sensor with nanoscale precision. Starting from a 24-helix bundle, two distinct DNA origami structures were designed to position thrombin-specific aptamers with different density and distance (27 and 113 nm) from the FO-SPR surface. The origami-based biosensors proved to be not only capable of reproducible, label-free thrombin detection, but revealed also valuable innovative features: (1) a significantly better performance in the absence of backfilling, known as essential in biosensing field, suggesting improved bioreceptor orientation and accessibility and (2) a wider linear range compared to previously reported thrombin biosensors. We envisage that our method will be beneficial both for scientists and clinicians looking for new surface (bio)chemistry and improved diagnostics.

  9. A Highly Controllable Electrochemical Anodization Process to Fabricate Porous Anodic Aluminum Oxide Membranes

    NASA Astrophysics Data System (ADS)

    Lin, Yuanjing; Lin, Qingfeng; Liu, Xue; Gao, Yuan; He, Jin; Wang, Wenli; Fan, Zhiyong

    2015-12-01

    Due to the broad applications of porous alumina nanostructures, research on fabrication of anodized aluminum oxide (AAO) with nanoporous structure has triggered enormous attention. While fabrication of highly ordered nanoporous AAO with tunable geometric features has been widely reported, it is known that its growth rate can be easily affected by the fluctuation of process conditions such as acid concentration and temperature during electrochemical anodization process. To fabricate AAO with various geometric parameters, particularly, to realize precise control over pore depth for scientific research and commercial applications, a controllable fabrication process is essential. In this work, we revealed a linear correlation between the integrated electric charge flow throughout the circuit in the stable anodization process and the growth thickness of AAO membranes. With this understanding, we developed a facile approach to precisely control the growth process of the membranes. It was found that this approach is applicable in a large voltage range, and it may be extended to anodization of other metal materials such as Ti as well.

  10. A Highly Controllable Electrochemical Anodization Process to Fabricate Porous Anodic Aluminum Oxide Membranes.

    PubMed

    Lin, Yuanjing; Lin, Qingfeng; Liu, Xue; Gao, Yuan; He, Jin; Wang, Wenli; Fan, Zhiyong

    2015-12-01

    Due to the broad applications of porous alumina nanostructures, research on fabrication of anodized aluminum oxide (AAO) with nanoporous structure has triggered enormous attention. While fabrication of highly ordered nanoporous AAO with tunable geometric features has been widely reported, it is known that its growth rate can be easily affected by the fluctuation of process conditions such as acid concentration and temperature during electrochemical anodization process. To fabricate AAO with various geometric parameters, particularly, to realize precise control over pore depth for scientific research and commercial applications, a controllable fabrication process is essential. In this work, we revealed a linear correlation between the integrated electric charge flow throughout the circuit in the stable anodization process and the growth thickness of AAO membranes. With this understanding, we developed a facile approach to precisely control the growth process of the membranes. It was found that this approach is applicable in a large voltage range, and it may be extended to anodization of other metal materials such as Ti as well.

  11. Quantification of Hydroxychloroquine in Blood Using Turbulent Flow Liquid Chromatography-Tandem Mass Spectrometry (TFLC-MS/MS).

    PubMed

    Chambliss, Allison B; Füzéry, Anna K; Clarke, William A

    2016-01-01

    Hydroxychloroquine (HQ) is used routinely in the treatment of autoimmune disorders such as rheumatoid arthritis and lupus erythematosus. Issues such as marked pharmacokinetic variability and patient non-compliance make therapeutic drug monitoring of HQ a useful tool for management of patients taking this drug. Quantitative measurements of HQ may aid in identifying poor efficacy as well as provide reliable information to distinguish patient non-compliance from refractory disease. We describe a rapid 7-min assay for the accurate and precise measurement of HQ concentrations in 100 μL samples of human blood using turbulent flow liquid chromatography coupled to tandem mass spectrometry. HQ is isolated from EDTA whole blood after a simple extraction with its deuterated analog, hydroxychloroquine-d4, in 0.33 M perchloric acid. Samples are then centrifuged and injected onto the TFLC-MS/MS system. Quantification is performed using a nine-point calibration curve that is linear over a wide range (15.7-4000 ng/mL) with precisions of <5 %.

  12. Simultaneous quantification of withanolides in Withania somnifera by a validated high-performance thin-layer chromatographic method.

    PubMed

    Srivastava, Pooja; Tiwari, Neerja; Yadav, Akhilesh K; Kumar, Vijendra; Shanker, Karuna; Verma, Ram K; Gupta, Madan M; Gupta, Anil K; Khanuja, Suman P S

    2008-01-01

    This paper describes a sensitive, selective, specific, robust, and validated densitometric high-performance thin-layer chromatographic (HPTLC) method for the simultaneous determination of 3 key withanolides, namely, withaferin-A, 12-deoxywithastramonolide, and withanolide-A, in Ashwagandha (Withania somnifera) plant samples. The separation was performed on aluminum-backed silica gel 60F254 HPTLC plates using dichloromethane-methanol-acetone-diethyl ether (15 + 1 + 1 + 1, v/v/v/v) as the mobile phase. The withanolides were quantified by densitometry in the reflection/absorption mode at 230 nm. Precise and accurate quantification could be performed in the linear working concentration range of 66-330 ng/band with good correlation (r2 = 0.997, 0.999, and 0.996, respectively). The method was validated for recovery, precision, accuracy, robustness, limit of detection, limit of quantitation, and specificity according to International Conference on Harmonization guidelines. Specificity of quantification was confirmed using retention factor (Rf) values, UV-Vis spectral correlation, and electrospray ionization mass spectra of marker compounds in sample tracks.

  13. Research on accuracy analysis of laser transmission system based on Zemax and Matlab

    NASA Astrophysics Data System (ADS)

    Chen, Haiping; Liu, Changchun; Ye, Haixian; Xiong, Zhao; Cao, Tingfen

    2017-05-01

    Laser transmission system is important in high power solid-state laser facilities and its function is to transfer and focus the light beam in accordance with the physical function of the facility. This system is mainly composed of transmission mirror modules and wedge lens module. In order to realize the precision alignment of the system, the precision alignment of the system is required to be decomposed into the allowable range of the calibration error of each module. The traditional method is to analyze the error factors of the modules separately, and then the linear synthesis is carried out, and the influence of the multi-module and multi-factor is obtained. In order to analyze the effect of the alignment error of each module on the beam center and focus more accurately, this paper aims to combine with the Monte Carlo random test and ray tracing, analyze influence of multi-module and multi-factor on the center of the beam, and evaluate and optimize the results of accuracy decomposition.

  14. A comparative study between three stability indicating spectrophotometric methods for the determination of diatrizoate sodium in presence of its cytotoxic degradation product based on two-wavelength selection.

    PubMed

    Riad, Safaa M; El-Rahman, Mohamed K Abd; Fawaz, Esraa M; Shehata, Mostafa A

    2015-06-15

    Three sensitive, selective, and precise stability indicating spectrophotometric methods for the determination of the X-ray contrast agent, diatrizoate sodium (DTA) in the presence of its acidic degradation product (highly cytotoxic 3,5-diamino metabolite) and in pharmaceutical formulation, were developed and validated. The first method is ratio difference, the second one is the bivariate method, and the third one is the dual wavelength method. The calibration curves for the three proposed methods are linear over a concentration range of 2-24 μg/mL. The selectivity of the proposed methods was tested using laboratory prepared mixtures. The proposed methods have been successfully applied to the analysis of DTA in pharmaceutical dosage forms without interference from other dosage form additives. The results were statistically compared with the official US pharmacopeial method. No significant difference for either accuracy or precision was observed. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Simultaneous determination of a binary mixture of pantoprazole sodium and itopride hydrochloride by four spectrophotometric methods.

    PubMed

    Ramadan, Nesrin K; El-Ragehy, Nariman A; Ragab, Mona T; El-Zeany, Badr A

    2015-02-25

    Four simple, sensitive, accurate and precise spectrophotometric methods were developed for the simultaneous determination of a binary mixture containing Pantoprazole Sodium Sesquihydrate (PAN) and Itopride Hydrochloride (ITH). Method (A) is the derivative ratio method ((1)DD), method (B) is the mean centering of ratio spectra method (MCR), method (C) is the ratio difference method (RD) and method (D) is the isoabsorptive point coupled with third derivative method ((3)D). Linear correlation was obtained in range 8-44 μg/mL for PAN by the four proposed methods, 8-40 μg/mL for ITH by methods A, B and C and 10-40 μg/mL for ITH by method D. The suggested methods were validated according to ICH guidelines. The obtained results were statistically compared with those obtained by the official and a reported method for PAN and ITH, respectively, showing no significant difference with respect to accuracy and precision. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Simultaneous determination of a binary mixture of pantoprazole sodium and itopride hydrochloride by four spectrophotometric methods

    NASA Astrophysics Data System (ADS)

    Ramadan, Nesrin K.; El-Ragehy, Nariman A.; Ragab, Mona T.; El-Zeany, Badr A.

    2015-02-01

    Four simple, sensitive, accurate and precise spectrophotometric methods were developed for the simultaneous determination of a binary mixture containing Pantoprazole Sodium Sesquihydrate (PAN) and Itopride Hydrochloride (ITH). Method (A) is the derivative ratio method (1DD), method (B) is the mean centering of ratio spectra method (MCR), method (C) is the ratio difference method (RD) and method (D) is the isoabsorptive point coupled with third derivative method (3D). Linear correlation was obtained in range 8-44 μg/mL for PAN by the four proposed methods, 8-40 μg/mL for ITH by methods A, B and C and 10-40 μg/mL for ITH by method D. The suggested methods were validated according to ICH guidelines. The obtained results were statistically compared with those obtained by the official and a reported method for PAN and ITH, respectively, showing no significant difference with respect to accuracy and precision.

  17. A novel spectrofluorimetric method for the assay of pseudoephedrine hydrochloride in pharmaceutical formulations via derivatization with 4-chloro-7-nitrobenzofurazan.

    PubMed

    El-Didamony, Akram M; Gouda, Ayman A

    2011-01-01

    A new highly sensitive and specific spectrofluorimetric method has been developed to determine a sympathomimetic drug pseudoephedrine hydrochloride. The present method was based on derivatization with 4-chloro-7-nitrobenzofurazan in phosphate buffer at pH 7.8 to produce a highly fluorescent product which was measured at 532 nm (excitation at 475 nm). Under the optimized conditions a linear relationship and good correlation was found between the fluorescence intensity and pseudoephedrine hydrochloride concentration in the range of 0.5-5 µg mL(-1). The proposed method was successfully applied to the assay of pseudoephedrine hydrochloride in commercial pharmaceutical formulations with good accuracy and precision and without interferences from common additives. Statistical comparison of the results with a well-established method showed excellent agreement and proved that there was no significant difference in the accuracy and precision. The stoichiometry of the reaction was determined and the reaction pathway was postulated. Copyright © 2010 John Wiley & Sons, Ltd.

  18. Derivative spectrophotometric method for simultaneous determination of clindamycin phosphate and tretinoin in pharmaceutical dosage forms.

    PubMed

    Barazandeh Tehrani, Maliheh; Namadchian, Melika; Fadaye Vatan, Sedigheh; Souri, Effat

    2013-04-10

    A derivative spectrophotometric method was proposed for the simultaneous determination of clindamycin and tretinoin in pharmaceutical dosage forms. The measurement was achieved using the first and second derivative signals of clindamycin at (1D) 251 nm and (2D) 239 nm and tretinoin at (1D) 364 nm and (2D) 387 nm.The proposed method showed excellent linearity at both first and second derivative order in the range of 60-1200 and 1.25-25 μg/ml for clindamycin phosphate and tretinoin respectively. The within-day and between-day precision and accuracy was in acceptable range (CV<3.81%, error<3.20%). Good agreement between the found andadded concentrations indicates successful application of the proposed method for simultaneous determination of clindamycin and tretinoin in synthetic mixtures and pharmaceutical dosage form.

  19. Quantitative determination of dimethylaminoethanol in cosmetic formulations by nuclear magnetic resonance spectroscopy.

    PubMed

    Batista, Ivani Aparecida Soares de Andrade; Gonçalves, Maria Inês de Almeida; Singh, Anil Kumar; Hackmann, Erika Rosa Maria Kedor; Santoro, Maria Inês Rocha Miritello

    2008-01-01

    A nuclear magnetic resonance (NMR) spectroscopic method was validated for the quantitative determination of dimethylaminoethanol (DMAE) in cosmetic formulations. The linearity in the range from 0.5000 to 1.5000 g (DMAE salt/mass maleic acid) presents a correlation coefficient > 0.99 for all DMAE salts. The repeatability (intraday), expressed as relative standard deviation, ranged from 1.08 to 1.44% for samples and 1.31 to 1.88% for raw materials. The detection limit and quantitation limit were 0.0017 and 0.0051 g for DMAE, 0.0018 and 0.0054 g for DMAE bitartrate, and 0.0023 and 0.0071 g for DMAE acetamidobenzoate, respectively. The proposed method is simple, precise, and accurate and can be used in the quality control of raw materials and cosmetic gels containing these compounds as active substances.

  20. Stability of warped AdS3 vacua of topologically massive gravity

    NASA Astrophysics Data System (ADS)

    Anninos, Dionysios; Esole, Mboyo; Guica, Monica

    2009-10-01

    AdS3 vacua of topologically massive gravity (TMG) have been shown to be perturbatively unstable for all values of the coupling constant except the chiral point μl = 1. We study the possibility that the warped vacua of TMG, which exist for all values of μ, are stable under linearized perturbations. In this paper, we show that spacelike warped AdS3 vacua with Compère-Detournay boundary conditions are indeed stable in the range μl>3. This is precisely the range in which black hole solutions arise as discrete identifications of the warped AdS3 vacuum. The situation somewhat resembles chiral gravity: although negative energy modes do exist, they are all excluded by the boundary conditions, and the perturbative spectrum solely consists of boundary (pure large gauge) gravitons.

  1. Spectrophotometric Determination of Poorly Water Soluble Drug Rosiglitazone Using Hydrotropic Solubilization technique.

    PubMed

    Sherje, A P; Desai, K J

    2011-09-01

    In the present investigation, hydrotropic solution of urea was employed as a solubilizing agent for spectrophotometric determination of poorly water-soluble drug rosiglitazone maleate. In solubility determination study, it was found that there was more than 14-folds enhancement in solubility of rosiglitazone maleate in a 6M solution of urea. Rosiglitazone maleate obeys Beer's law in concentration range of 5-300 μg/ml. Linearity of rosiglitazone maleate was found in the range of 80-120% of the label claim. The proposed method has been applied successfully to the analysis of the cited drug in pharmaceutical formulations with good accuracy and precision. The method herein described is new, simple, eco-friendly, economic, and accurate and can be utilized in routine analysis of rosiglitazone maleate in bulk drug and tablet dosage form.

  2. Spectrophotometric Determination of Poorly Water Soluble Drug Rosiglitazone Using Hydrotropic Solubilization technique

    PubMed Central

    Sherje, A. P.; Desai, K. J.

    2011-01-01

    In the present investigation, hydrotropic solution of urea was employed as a solubilizing agent for spectrophotometric determination of poorly water-soluble drug rosiglitazone maleate. In solubility determination study, it was found that there was more than 14-folds enhancement in solubility of rosiglitazone maleate in a 6M solution of urea. Rosiglitazone maleate obeys Beer's law in concentration range of 5-300 μg/ml. Linearity of rosiglitazone maleate was found in the range of 80-120% of the label claim. The proposed method has been applied successfully to the analysis of the cited drug in pharmaceutical formulations with good accuracy and precision. The method herein described is new, simple, eco-friendly, economic, and accurate and can be utilized in routine analysis of rosiglitazone maleate in bulk drug and tablet dosage form. PMID:22923874

  3. Simultaneous determination of gatifloxacin and ambroxol hydrochloride from tablet dosage form using reversed-phase high performance liquid chromatography.

    PubMed

    Shahed, Mirza; Nanda, Rabindra; Dehghan, Muhammad Hassan; Nasreen, Huda; Feroz, Shaikh

    2008-05-01

    A reversed-phase high performance liquid chromatography (HPLC) method was developed, validated, and used for the quantitative determination of gatifloxacin (GA) and ambroxol hydrochloride (AM), from its tablet dosage form. Chromatographic separation was performed on a HiQ Sil C18 column (250 mm x 4.6 mm, 5 microm), with a mobile phase comprising of a mixture of 0.01 mol/L potassium dihydrogen orthophosphate buffer and acetonitrile (70 : 30, v/v), and pH adjusted to 3 with orthophosphoric acid, at a flow rate of 1 mL/min, with detection at 247 nm. Separation was completed in less than 10 min. As per International Conference on Harmonisation (ICH) guidelines the method was validated for linearity, accuracy, precision, limit of quantitation, limit of detection, and robustness. Linearity of GA was found to be in the range of 10 -60 microg/mL and that for AM was found to be 5 - 30 microg/mL. The correlation coefficients were 0.999 6 and 0.999 3 for GA and AM respectively. The results of the tablet analysis (n = 5) were found to be 99.94% with +/- 0.25% standard deviation (SD) and 99.98% with +/- 0.36% SD for GA and AM respectively. Percent recovery of GA was found to be 99.92% - 100.02% and that of AM was 99.86% - 100.16%. The assay experiment shows that the method is free from interference of excipients. This demonstrates that the developed HPLC method is simple, linear, precise, and accurate, and can be conveniently adopted for the routine quality control analysis of the tablet.

  4. Measurement of HbA1c in Gingival Crevicular Blood Using a High-Pressure Liquid Chromatography Procedure.

    PubMed

    Pesce, Michael A; Strauss, Shiela M; Rosedale, Mary; Netterwald, Jane; Wang, Hangli

    2015-01-01

    To validate an ion exchange high-pressure liquid chromatography (HPLC) method for measuring glycated hemoglobin (HbA1c) in gingival crevicular blood (GCB) spotted on filter paper, for use in screening dental patients for diabetes. We collected the GCB specimens for this study from the oral cavities of patients during dental visits, using rigorous strategies to obtain GCB that was as free of debris as possible. The analytical performance of the HPLC method was determined by measuring the precision, linearity, carryover, stability of HbA1c in GCB, and correlation of HbA1c results in GCB specimens with finger-stick blood (FSB) specimens spotted on filter paper. The coefficients of variation (CVs) for the inter- and intrarun precision of the method were less than 2.0%. Linearity ranged between 4.2% and 12.4%; carryover was less than 2.0%, and the stability of the specimen was 6 days at 4°C and as many as 14 days at -70°C. Linear regression analysis comparing the HbA1c results in GCB with FSB yielded a correlation coefficient of 0.993, a slope of 0.981, and an intercept of 0.13. The Bland-Altman plot showed no difference in the HbA1c results from the GCB and FSB specimens at normal, prediabetes, and diabetes HbA1c levels. We validated an HPLC method for measuring HbA1c in GCB; this method can be used to screen dental patients for diabetes. Copyright© by the American Society for Clinical Pathology (ASCP).

  5. Fitting and forecasting coupled dark energy in the non-linear regime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casas, Santiago; Amendola, Luca; Pettorino, Valeria

    2016-01-01

    We consider cosmological models in which dark matter feels a fifth force mediated by the dark energy scalar field, also known as coupled dark energy. Our interest resides in estimating forecasts for future surveys like Euclid when we take into account non-linear effects, relying on new fitting functions that reproduce the non-linear matter power spectrum obtained from N-body simulations. We obtain fitting functions for models in which the dark matter-dark energy coupling is constant. Their validity is demonstrated for all available simulations in the redshift range 0z=–1.6 and wave modes below 0k=1 h/Mpc. These fitting formulas can be used tomore » test the predictions of the model in the non-linear regime without the need for additional computing-intensive N-body simulations. We then use these fitting functions to perform forecasts on the constraining power that future galaxy-redshift surveys like Euclid will have on the coupling parameter, using the Fisher matrix method for galaxy clustering (GC) and weak lensing (WL). We find that by using information in the non-linear power spectrum, and combining the GC and WL probes, we can constrain the dark matter-dark energy coupling constant squared, β{sup 2}, with precision smaller than 4% and all other cosmological parameters better than 1%, which is a considerable improvement of more than an order of magnitude compared to corresponding linear power spectrum forecasts with the same survey specifications.« less

  6. An Open-Source Galaxy Redshift Survey Simulator for next-generation Large Scale Structure Surveys

    NASA Astrophysics Data System (ADS)

    Seijak, Uros

    Galaxy redshift surveys produce three-dimensional maps of the galaxy distribution. On large scales these maps trace the underlying matter fluctuations in a relatively simple manner, so that the properties of the primordial fluctuations along with the overall expansion history and growth of perturbations can be extracted. The BAO standard ruler method to measure the expansion history of the universe using galaxy redshift surveys is thought to be robust to observational artifacts and understood theoretically with high precision. These same surveys can offer a host of additional information, including a measurement of the growth rate of large scale structure through redshift space distortions, the possibility of measuring the sum of neutrino masses, tighter constraints on the expansion history through the Alcock-Paczynski effect, and constraints on the scale-dependence and non-Gaussianity of the primordial fluctuations. Extracting this broadband clustering information hinges on both our ability to minimize and subtract observational systematics to the observed galaxy power spectrum, and our ability to model the broadband behavior of the observed galaxy power spectrum with exquisite precision. Rapid development on both fronts is required to capitalize on WFIRST's data set. We propose to develop an open-source computational toolbox that will propel development in both areas by connecting large scale structure modeling and instrument and survey modeling with the statistical inference process. We will use the proposed simulator to both tailor perturbation theory and fully non-linear models of the broadband clustering of WFIRST galaxies and discover novel observables in the non-linear regime that are robust to observational systematics and able to distinguish between a wide range of spatial and dynamic biasing models for the WFIRST galaxy redshift survey sources. We have demonstrated the utility of this approach in a pilot study of the SDSS-III BOSS galaxies, in which we improved the redshift space distortion growth rate measurement precision by a factor of 2.5 using customized clustering statistics in the non-linear regime that were immunized against observational systematics. We look forward to addressing the unique challenges of modeling and empirically characterizing the WFIRST galaxies and observational systematics.

  7. A critical evaluation of liquid chromatography with hybrid linear ion trap-Orbitrap mass spectrometry for the determination of acidic contaminants in wastewater effluents.

    PubMed

    Cahill, Michael G; Dineen, Brian A; Stack, Mary A; James, Kevin J

    2012-12-28

    Acidic pesticide and pharmaceutical contaminants were pre-concentrated and extracted from wastewater samples (500 mL) using solid-phase extraction. Analyte recoveries were 79-96%, with % RSD values in the range, 1.7-7.4%. Analyte identification and quantification were carried out using liquid chromatography-mass spectrometry (LC-MS) with hybrid linear ion trap (LIT) Orbitrap instrumentation. Using a resolution setting of 30,000 FWHM, full-scan MS analysis was performed using heated electrospray ionization (HESI) in negative mode. The high mass resolution capabilities of the Orbitrap MS were exploited for the determination of trace contaminants allowing facile discrimination between analytes and matrix. The dependant scan functions of the Orbitrap MS using higher collisional dissociation (HCD) and LIT MS were evaluated for the confirmation of analytes at trace concentration levels. Mass accuracy for target contaminants using this method was less than 2 ppm. The limits of quantitation (LOQs) were in the range, 2.1-27 ng/L. The inter-day accuracy and precision were measured over a five-day period at two concentrations. The % relative errors were in the range, 0.30-7.7%, and the % RSD values were in the range, 1.5-5.5%. Using this method, 2,4-D, mecoprop, ibuprofen, naproxene and gemfibrozil were identified in several wastewater treatment plants in Ireland. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Electrochemical Impedance Spectrometer with an Environmental Chamber for Rapid Screening of New Precise Copolymers

    DTIC Science & Technology

    2017-10-07

    polymerization to make linear polyethylenes with carboxylic acid groups at precise intervals along the polymer . Precise acid- containing polymers provide...acid polyethylene and the a polymerized ionic liquids based on cyclopropenium. The instrument is also be used to study polymer segmental dynamics...Advances in batteries, fuel cells, and permselective membranes are materials limited. New acid- and ion-containing polymers must be designed and

  9. Modified Chapman-Enskog moment approach to diffusive phonon heat transport.

    PubMed

    Banach, Zbigniew; Larecki, Wieslaw

    2008-12-01

    A detailed treatment of the Chapman-Enskog method for a phonon gas is given within the framework of an infinite system of moment equations obtained from Callaway's model of the Boltzmann-Peierls equation. Introducing no limitations on the magnitudes of the individual components of the drift velocity or the heat flux, this method is used to derive various systems of hydrodynamic equations for the energy density and the drift velocity. For one-dimensional flow problems, assuming that normal processes dominate over resistive ones, it is found that the first three levels of the expansion (i.e., the zeroth-, first-, and second-order approximations) yield the equations of hydrodynamics which are linearly stable at all wavelengths. This result can be achieved either by examining the dispersion relations for linear plane waves or by constructing the explicit quadratic Lyapunov entropy functionals for the linear perturbation equations. The next order in the Chapman-Enskog expansion leads to equations which are unstable to some perturbations. Precisely speaking, the linearized equations of motion that describe the propagation of small disturbances in the flow have unstable plane-wave solutions in the short-wavelength limit of the dispersion relations. This poses no problem if the equations are used in their proper range of validity.

  10. Listing triangles in expected linear time on a class of power law graphs.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nordman, Daniel J.; Wilson, Alyson G.; Phillips, Cynthia Ann

    Enumerating triangles (3-cycles) in graphs is a kernel operation for social network analysis. For example, many community detection methods depend upon finding common neighbors of two related entities. We consider Cohen's simple and elegant solution for listing triangles: give each node a 'bucket.' Place each edge into the bucket of its endpoint of lowest degree, breaking ties consistently. Each node then checks each pair of edges in its bucket, testing for the adjacency that would complete that triangle. Cohen presents an informal argument that his algorithm should run well on real graphs. We formalize this argument by providing an analysismore » for the expected running time on a class of random graphs, including power law graphs. We consider a rigorously defined method for generating a random simple graph, the erased configuration model (ECM). In the ECM each node draws a degree independently from a marginal degree distribution, endpoints pair randomly, and we erase self loops and multiedges. If the marginal degree distribution has a finite second moment, it follows immediately that Cohen's algorithm runs in expected linear time. Furthermore, it can still run in expected linear time even when the degree distribution has such a heavy tail that the second moment is not finite. We prove that Cohen's algorithm runs in expected linear time when the marginal degree distribution has finite 4/3 moment and no vertex has degree larger than {radical}n. In fact we give the precise asymptotic value of the expected number of edge pairs per bucket. A finite 4/3 moment is required; if it is unbounded, then so is the number of pairs. The marginal degree distribution of a power law graph has bounded 4/3 moment when its exponent {alpha} is more than 7/3. Thus for this class of power law graphs, with degree at most {radical}n, Cohen's algorithm runs in expected linear time. This is precisely the value of {alpha} for which the clustering coefficient tends to zero asymptotically, and it is in the range that is relevant for the degree distribution of the World-Wide Web.« less

  11. Resimulation of noise: a precision estimator for least square error curve-fitting tested for axial strain time constant imaging

    NASA Astrophysics Data System (ADS)

    Nair, S. P.; Righetti, R.

    2015-05-01

    Recent elastography techniques focus on imaging information on properties of materials which can be modeled as viscoelastic or poroelastic. These techniques often require the fitting of temporal strain data, acquired from either a creep or stress-relaxation experiment to a mathematical model using least square error (LSE) parameter estimation. It is known that the strain versus time relationships for tissues undergoing creep compression have a non-linear relationship. In non-linear cases, devising a measure of estimate reliability can be challenging. In this article, we have developed and tested a method to provide non linear LSE parameter estimate reliability: which we called Resimulation of Noise (RoN). RoN provides a measure of reliability by estimating the spread of parameter estimates from a single experiment realization. We have tested RoN specifically for the case of axial strain time constant parameter estimation in poroelastic media. Our tests show that the RoN estimated precision has a linear relationship to the actual precision of the LSE estimator. We have also compared results from the RoN derived measure of reliability against a commonly used reliability measure: the correlation coefficient (CorrCoeff). Our results show that CorrCoeff is a poor measure of estimate reliability for non-linear LSE parameter estimation. While the RoN is specifically tested only for axial strain time constant imaging, a general algorithm is provided for use in all LSE parameter estimation.

  12. Determination of Iron Ion in the Water of a Natural Hot Spring Using Microfluidic Paper-based Analytical Devices.

    PubMed

    Ogawa, Kazuma; Kaneta, Takashi

    2016-01-01

    Microfluidic paper-based analytical devices (μPADs) were used to detect the iron ion content in the water of a natural hot spring in order to assess the applicability of this process to the environmental analysis of natural water. The μPADs were fabricated using a wax printer after the addition of hydroxylamine into the detection reservoirs to reduce Fe(3+) to Fe(2+), 1,10-phenanthroline for the forming of a complex, and poly(acrylic acid) for ion-pair formation with an acetate buffer (pH 4.7). The calibration curve of Fe(3+) showed a linearity that ranged from 100 to 1000 ppm in the semi-log plot whereas the color intensity was proportional to the concentration of Fe(3+) and ranged from 40 to 350 ppm. The calibration curve represented the daily fluctuation in successive experiments during four days, which indicated that a calibration curve must be constructed for each day. When freshly prepared μPADs were compared with stored ones, no significant difference was found. The μPADs were applied to the determination of Fe(3+) in a sample of water from a natural hot spring. Both the accuracy and the precision of the μPAD method were evaluated by comparisons with the results obtained via conventional spectrophotometry. The results of the μPADs were in good agreement with, but less precise than, those obtained via conventional spectrophotometry. Consequently, the μPADs offer advantages that include rapid and miniaturized operation, although the precision was poorer than that of conventional spectrophotometry.

  13. Selective optical sensing of biothiols with Ellman's reagent: 5,5'-Dithio-bis(2-nitrobenzoic acid)-modified gold nanoparticles.

    PubMed

    Güçlü, Kubilay; Ozyürek, Mustafa; Güngör, Nilay; Baki, Sefa; Apak, Reşat

    2013-09-10

    Development of sensitive and selective methods of determination for biothiols is important because of their significant roles in biological systems. We present a new optical sensor using Ellman's reagent (DTNB)-adsorbed gold nanoparticles (Au-NPs) (DTNB-Au-NP) in a colloidal solution devised to selectively determine biologically important thiols (biothiols) from biological samples and pharmaceuticals. 5,5'-Dithio-bis(2-nitrobenzoic acid) (DTNB), a versatile water-soluble compound for quantitating free sulfhydryl groups in solution, was adsorbed through non-covalent interaction onto Au-NPs, and the absorbance changes associated with the formation of the yellow-colored 5-thio-2-nitrobenzoate (TNB(2-)) anion as a result of reaction with biothiols was measured at 410nm. The sensor gave a linear response over a wide concentration range of standard biothiols comprising cysteine, glutathione, homocysteine, cysteamine, dihydrolipoic acid and 1,4-dithioerythritol. The calibration curves of individual biothiols were constructed, and their molar absorptivities and linear concentration ranges determined. The cysteine equivalent thiol content (CETC) values of various biothiols using the DTNB-Au-NP assay were comparable to those of the conventional DTNB assay, showing that the immobilized DTNB reagent retained its reactivity toward thiols. Common biological sample ingredients like amino acids, flavonoids, vitamins, and plasma antioxidants did not interfere with the proposed sensing method. This assay was validated through linearity, additivity, precision and recovery, demonstrating that the assay is reliable and robust. DTNB-adsorbed Au-NPs probes provided higher sensitivity (i.e., lower detection limits) in biothiol determination than conventional DTNB reagent. Under optimized conditions, cysteine (Cys) was quantified by the proposed assay, with a detection limit (LOD) of 0.57μM and acceptable linearity ranging from 0.4 to 29.0μM (r=0.998). Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Optimal moving grids for time-dependent partial differential equations

    NASA Technical Reports Server (NTRS)

    Wathen, A. J.

    1989-01-01

    Various adaptive moving grid techniques for the numerical solution of time-dependent partial differential equations were proposed. The precise criterion for grid motion varies, but most techniques will attempt to give grids on which the solution of the partial differential equation can be well represented. Moving grids are investigated on which the solutions of the linear heat conduction and viscous Burgers' equation in one space dimension are optimally approximated. Precisely, the results of numerical calculations of optimal moving grids for piecewise linear finite element approximation of partial differential equation solutions in the least squares norm.

  15. Optimal moving grids for time-dependent partial differential equations

    NASA Technical Reports Server (NTRS)

    Wathen, A. J.

    1992-01-01

    Various adaptive moving grid techniques for the numerical solution of time-dependent partial differential equations were proposed. The precise criterion for grid motion varies, but most techniques will attempt to give grids on which the solution of the partial differential equation can be well represented. Moving grids are investigated on which the solutions of the linear heat conduction and viscous Burgers' equation in one space dimension are optimally approximated. Precisely, the results of numerical calculations of optimal moving grids for piecewise linear finite element approximation of PDE solutions in the least-squares norm are reported.

  16. Measuring Solar Coronal Magnetism during the Total Solar Eclipse of 2017

    NASA Astrophysics Data System (ADS)

    Gibson, K. L.; Tomczyk, S.

    2017-12-01

    The total solar eclipse on August 21, 2017 provided a notable opportunity to measure the solar corona at specific emission wavelengths to gain information about coronal magnetic fields. Solar magnetic fields are intimately related to the generation of space weather and its effects on the earth, and the infrared imaging and polarization information collected on coronal emission lines here will enhance the scientific value of several other ongoing experiments, as well as benefit the astrophysics and upper atmosphere communities. Coronal measurements were collected during the 2 minute and 24 second totality period from Casper Mountain, WY. Computer-controlled telescopes automatically inserted four different narrow band pass filters to capture images in the visible range on a 4D PolCam, and in the infrared range on the FLIR 8501c camera. Each band pass filter selects a specific wavelength range that corresponds to a known coronal emission line possessing magnetic sensitivity. The 4D PolCam incorporated a novel grid of linear polarizers precisely aligned with the micron scale pixels. This allowed for direct measurement of the degree of linear polarization in a very small instrument with no external moving parts as is typically required. The FLIR offers short exposure times to freeze motion and output accurate thermal measurements. This allowed a new observation of the sun's corona using thermo infrared technology.

  17. Simultaneous quantification of polymethoxylated flavones and coumarins in Fructus aurantii and Fructus aurantii immaturus using HPLC-ESI-MS/MS.

    PubMed

    Chen, Hai-Fang; Zhang, Wu-Gang; Yuan, Jin-Bin; Li, Yan-Gang; Yang, Shi-Lin; Yang, Wu-Liang

    2012-02-05

    The major lipid-soluble constituents in Fructus aurantii (zhiqiao) and Fructus aurantii immaturus (zhishi) are polymethoxylated flavones (PMFs) and coumarins. In the present study, a high-performance liquid chromatography with electrospray ionization tandem mass spectrometry method was developed to quantify PMFs (nobiletin, tangeretin, 5-hydroxy-6,7,8,4'-tetramethoxyflavone, and natsudaidai) and coumarins (marmin, meranzin hydrate, and auraptene) simultaneously. PMFs and coumarins were detected by electrospray ionization tandem mass spectrometry in positive ion mode and quantified with multiple reaction monitor. Samples were separated on a Diamonsil C₁₈ (150 mm × 4.6 mm, 5 μm) column using acetonitrile and formic acid-water solution as a mobile phase in gradient mode with a flow rate at 0.5 mL/min. All calibration curves showed good linearity (r² > 0.9977) within the test ranges. Variations of the intraday and interday precisions were less than 4.07%. The recoveries of the components were within the range of 95.79%-105.04% and the relative standard deviations were less than 3.82%. The method developed was validated with acceptable accuracy, precision, and extraction recoveries and can be applied for the identification and quantification of four PMFs and three coumarins in citrus herbs. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Preliminary investigation of electrothermal vaporization sample introduction for inductively coupled plasma time-of-flight mass spectrometry.

    PubMed

    Mahoney, P P; Ray, S J; Li, G; Hieftje, G M

    1999-04-01

    The coupling of an electrothermal vaporization (ETV) apparatus to an inductively coupled plasma time-of-flight mass spectrometer (ICP-TOFMS) is described. The ability of the ICP-TOFMS to produce complete elemental mass spectra at high repetition rates is experimentally demonstrated. A signal-averaging data acquisition board is employed to rapidly record complete elemental spectra throughout the vaporization stage of the ETV temperature cycle; a solution containing 34 elements is analyzed. The reduction of both molecular and atomic isobaric interferences through the temperature program of the furnace is demonstrated. Isobaric overlaps among the isotopes of cadmium, tin, and indium are resolved by exploiting differences in the vaporization characteristics of the elements. Figures of merit for the system are defined with several different data acquisition schemes capable of operating at the high repetition rate of the TOF instrument. With the use of both ion counting and a boxcar averager, the dynamic range is shown to be linear over a range of at least 6 orders of magnitude. A pair of boxcar averagers are used to measure the isotope ratio for silver with a precision of 1.9% RSD, despite a cycle-to-cycle precision of 19% RSD. Detection limits of 10-80 fg are calculated for seven elements, based upon a 10-microL injection.

  19. Separation and determination of synthetic impurities of difloxacin by reversed-phase high-performance liquid chromatography.

    PubMed

    Rao, R Nageswara; Nagaraju, V

    2004-11-19

    A simple and rapid reversed-phase high-performance liquid chromatographic method for separation and determination of process-related impurities of difloxacin (DFL) was developed. The separation was achieved on a reversed-phase C(18) column using methanol-water-acetic acid (78:21.9:0.1, v/v/v) as a mobile solvent at a flow rate of 1.0 ml/min at 28 degrees C using UV detection at 230 nm. It was linear over a range of 0.03 x 10(-6) to 1.60 x 10(-6)g for process related impurities and 0.05 x 10(-6) to 2.40 x 10(-6)g for difloxacin. The detection limits were 0.009 x 10(-6) to 0.024 x 10(-6)g for all the compounds examined. The recoveries were found to be in the range of 97.6-102.0% for impurities as well as difloxacin. The precision and robustness of the method were evaluated. It was used for not only quality assurance, but also monitoring the synthetic reactions involved in the process development work of difloxacin. The method was found to be specific, precise and reliable for the determination of unreacted levels of raw materials, intermediates in the reaction mixtures and the finished products of difloxacin.

  20. Determination of quinolones and fluoroquinolones, tetracyclines and sulfonamides in bovine, swine and poultry liver using LC-MS/MS.

    PubMed

    Martins, Magda Targa; Barreto, Fabiano; Hoff, Rodrigo Barcelos; Jank, Louise; Arsand, Juliana Bazzan; Feijó, Tiago Correa; Schapoval, Elfrides Eva Scherman

    2015-01-01

    Antibacterials are widely used in veterinary medicine. Residues of these drugs can remain in food of animal origin, including bovine liver. This paper describes a fast and simple analytical method for the determination of quinolones and fluoroquinolones, tetracyclines and sulfonamides in bovine liver samples. Deuterated enrofloxacin, sulfapyridine and demeclocycline were used as internal standards. The homogenised liver samples were extracted with acidified acetonitrile. Steps of non-solid-phase extraction (SPE) clean-up and concentration were used in the presented method. The final extracts were analysed by sensitive and selective detection of all components in a single run using LC-MS/MS. Acceptable recoveries between 66% and 110% were obtained. Good linearity (r(2)) above 0.96, considering three different days, for all drugs was achieved in concentrations ranging from 0.0 to 2.0 × the maximum residue limit (MRL). Intraday precision with coefficient of variation (CV%) (n = 6) lower than 14.7% and inter-day precision lower than 18.8% in agreement with European Commission Decision 2002/657/EC were obtained in concentrations ranging from 0.5 to 1.5 MRL. Accuracy was between 86% and 110%. Limits of detection and quantitation, as well as decision limit (CCα) and detection capability (CCβ), were also evaluated.

  1. Morphologies of precise polyethylene-based acid copolymers and ionomers

    NASA Astrophysics Data System (ADS)

    Buitrago, C. Francisco

    Acid copolymers and ionomers are polymers that contain a small fraction of covalently bound acidic or ionic groups, respectively. For the specific case of polyethylene (PE), acid and ionic pendants enhance many of the physical properties such as toughness, adhesion and rheological properties. These improved properties result from microphase separated aggregates of the polar pendants in the non-polar PE matrix. Despite the widespread industrial use of these materials, rigorous chemical structure---morphology---property relationships remain elusive due to the inevitable structural heterogeneities in the historically-available acid copolymers and ionomers. Recently, precise acid copolymers and ionomers were successfully synthesized by acyclic diene metathesis (ADMET) polymerization. These precise materials are linear, high molecular weight PEs with pendant acid or ionic functional groups separated by a precisely controlled number of carbon atoms. The morphologies of nine precise acid copolymers and eleven precise ionomers were investigated by X-ray scattering, solid-state 13C nuclear magnetic resonance (NMR) and differential scanning calorimetry (DSC). For comparison, the morphologies of linear PEs with pseudo-random placement of the pendant groups were also studied. Previous studies of precise copolymers with acrylic acid (AA) found that the microstructural precision produces a new morphology in which PE crystals drive the acid aggregates into layers perpendicular to the chain axes and presumably at the interface between crystalline and amorphous phases. In this dissertation, a second new morphology for acid copolymers is identified in which the aggregates arrange on cubic lattices. The fist report of a cubic morphology was observed at room and elevated temperatures for a copolymer functionalized with two phosphonic acid (PA) groups on every 21st carbon atom. The cubic lattice has been identified as face-centered cubic (FCC). Overall, three morphology types have been identified for precise acid copolymers and ionomers at room temperature: (1) liquid-like order of aggregates dispersed throughout an amorphous PE matrix, (2) one-dimensional long-range order of aggregates in layers coexisting with PE crystals, and (3) three-dimensional periodicity of aggregates in cubic lattices in a PE matrix featuring defective packing. The liquid-like morphology is a result of high content of acid or ionic substituents deterring PE crystallinity due to steric hindrance. The layered morphology occurs when the content of pendants is low and the PE segments are long enough to crystallize. The cubic morphologies occur in precise copolymers with geminal substitution of phosphonic acid (PA) groups and long, flexible PE segments. At temperatures above the thermal transitions of the PE matrix, all but one material present a liquid-like morphology. Those conditions are ideal to study the evolution of the interaggregate spacing (d*) in X-ray scattering as a function of PE segment length between pendants, pendant type and pendant architecture (specifically, mono or geminal substitution). Also at elevated temperatures, the morphologies of precise acrylic acid (AA) copolymers and ionomers were investigated further via atomistic molecular dynamics (MD) simulations. The simulations complement X-ray scattering by providing real space visualization of the aggregates, demonstrating the occurrence of isolated, string-like and even percolated aggregate structures. This is the first dissertation completely devoted to the morphology of precise acid copolymers and precise ionomers. The complete analysis of the morphologies in these novel materials provides new insights into the shapes of aggregates in acid copolymers and ionomers in general. A key aspect of this thesis is the complementary use of experimental and simulation methods to unlock a wealth of new understanding.

  2. Quantitative high-throughput determination of endogenous retinoids in human plasma using triple-stage liquid chromatography/tandem mass spectrometry.

    PubMed

    Gundersen, Thomas E; Bastani, Nasser E; Blomhoff, Rune

    2007-01-01

    A high-throughput ultrasensitive analytical method based on liquid chromatography with positive ion atmospheric pressure chemical ionization (APCI) coupled to tandem mass spectrometric detection (LC/MS/MS) was developed for the determination of all-trans-4-oxo-retinoic acid (at4oxoRA), 13-cis-4-oxo-retinoic acid (13c4oxoRA), 13-cis-retinoic acid (13cRA), all-trans-retinoic acid (atRA) and all-trans-retinol (atROH) in human plasma. A stable isotope of atRA was used as internal standard (IS). The analytes and IS were isolated from 100 microL plasma by acetonitrile mono-phase extraction (MPE) performed in black 96-well microtiterplates. A 100 microL injection was focused on-column and chromatographed on an Agilent ZORBAX SB-C18 rapid-resolution high-throughput (RRHT) column with 1.8-microm particles (4.6 mmx50 mm) maintained at 60 degrees C. The initial mobile phase composition was acetonitrile/water/formic acid (10:90:0.1, v/v/v) delivered at 1.8 mL/min. Elution was accomplished by a fast gradient to acetonitrile/methanol/formic acid (90:10:0.1, v/v/v). The method had a chromatographic total run time of 7 min. An Applied Biosystems 4000 Q TRAP linear tandem mass spectrometer equipped with a heated nebulizer (APCI) ionization source was operated in multiple reaction monitoring (MRM) mode with the precursor-to-product ion transitions m/z 315.4-->297 (4-oxo-retinoic acids), 301.2-->205 (retinoic acids), 305.0-->209 (IS) and 269.2-->93 (retinol) used for quantification. The assay was fully validated and found to have acceptable accuracy, precision, linearity, sensitivity and selectivity. The mean extraction recoveries from spiked plasma samples were 80-105% for the various retinoids at three different levels. The intra-day accuracy of the assay was within 8% of nominal and intra-day precision was better than 8% coefficient of variance (CV) for retinoic acids. Inter-day precision results for quality control samples run over a 12-day period alongside clinical samples showed mean precision better than 12.5% CV. The limit of quantification was in the range of 0.1-0.2 ng/mL and the mass limit of detection (mLOD) was in the range 1-4 pg on column for the retinoic acids. The assay has been successfully applied to the analysis of 1700 plasma samples. Copyright (c) 2007 John Wiley & Sons, Ltd.

  3. A simple and rapid chromatographic method to determine unauthorized basic colorants (rhodamine B, auramine O, and pararosaniline) in processed foods.

    PubMed

    Tatebe, Chiye; Zhong, Xining; Ohtsuki, Takashi; Kubota, Hiroki; Sato, Kyoko; Akiyama, Hiroshi

    2014-09-01

    A simple and rapid high-performance liquid chromatography (HPLC) method to determine basic colorants such as pararosaniline (PA), auramine O (AO), and rhodamine B (RB) in various processed foods was developed. Linearity of the calibration curves ranged from 0.05 to 50 μg/mL for PA and 0.05-100 μg/mL for AO and RB. The detection and quantification limits (LOD and LOQ) of the basic colorants, which were evaluated as signal-to-noise ratios of 3 for LOD and 10 for LOQ, ranged from 0.0125 to 0.05 and 0.025 to 0.125 μg/g, respectively. The recoveries and relative standard deviations of three basic colorants in six processed foods, namely, chili sauce, curry paste, gochujang (hot pepper paste), tandoori chicken (roasted chicken prepared with yogurt and spices), powder soup, and shrimp powder ranged from 70.2% to 102.8% and 0.8% to 8.0%, respectively. The intraday precision of the recovery test ranged from 1.7% to 4.5%, whereas the interday precision ranged from 3.7% to 7.7%. The reported method has been successfully applied to basic colorant determination in various processed foods such as fat-based food matrices (curry paste and tandoori chicken), chili products (gochujang and chili sauce), and protein-based products (shrimp powder and powder soup). Thin layer chromatography and liquid chromatography/mass spectrometry methods for the determination of basic colorants in processed foods were also developed for rapid analysis and identification, respectively. These methods are very useful for monitoring unauthorized basic colorants in inspection centers or quarantine laboratories in many countries.

  4. A new linear least squares method for T1 estimation from SPGR signals with multiple TRs

    NASA Astrophysics Data System (ADS)

    Chang, Lin-Ching; Koay, Cheng Guan; Basser, Peter J.; Pierpaoli, Carlo

    2009-02-01

    The longitudinal relaxation time, T1, can be estimated from two or more spoiled gradient recalled echo x (SPGR) images with two or more flip angles and one or more repetition times (TRs). The function relating signal intensity and the parameters are nonlinear; T1 maps can be computed from SPGR signals using nonlinear least squares regression. A widely-used linear method transforms the nonlinear model by assuming a fixed TR in SPGR images. This constraint is not desirable since multiple TRs are a clinically practical way to reduce the total acquisition time, to satisfy the required resolution, and/or to combine SPGR data acquired at different times. A new linear least squares method is proposed using the first order Taylor expansion. Monte Carlo simulations of SPGR experiments are used to evaluate the accuracy and precision of the estimated T1 from the proposed linear and the nonlinear methods. We show that the new linear least squares method provides T1 estimates comparable in both precision and accuracy to those from the nonlinear method, allowing multiple TRs and reducing computation time significantly.

  5. Precision Efficacy Analysis for Regression.

    ERIC Educational Resources Information Center

    Brooks, Gordon P.

    When multiple linear regression is used to develop a prediction model, sample size must be large enough to ensure stable coefficients. If the derivation sample size is inadequate, the model may not predict well for future subjects. The precision efficacy analysis for regression (PEAR) method uses a cross- validity approach to select sample sizes…

  6. Development and Preliminary Testing of a High Precision Long Stroke Slit Change Mechanism for the SPICE Instrument

    NASA Technical Reports Server (NTRS)

    Paciotti, Gabriel; Humphries, Martin; Rottmeier, Fabrice; Blecha, Luc

    2014-01-01

    In the frame of ESA's Solar Orbiter scientific mission, Almatech has been selected to design, develop and test the Slit Change Mechanism of the SPICE (SPectral Imaging of the Coronal Environment) instrument. In order to guaranty optical cleanliness level while fulfilling stringent positioning accuracies and repeatability requirements for slit positioning in the optical path of the instrument, a linear guiding system based on a double flexible blade arrangement has been selected. The four different slits to be used for the SPICE instrument resulted in a total stroke of 16.5 mm in this linear slit changer arrangement. The combination of long stroke and high precision positioning requirements has been identified as the main design challenge to be validated through breadboard models testing. This paper presents the development of SPICE's Slit Change Mechanism (SCM) and the two-step validation tests successfully performed on breadboard models of its flexible blade support system. The validation test results have demonstrated the full adequacy of the flexible blade guiding system implemented in SPICE's Slit Change Mechanism in a stand-alone configuration. Further breadboard test results, studying the influence of the compliant connection to the SCM linear actuator on an enhanced flexible guiding system design have shown significant enhancements in the positioning accuracy and repeatability of the selected flexible guiding system. Preliminary evaluation of the linear actuator design, including a detailed tolerance analyses, has shown the suitability of this satellite roller screw based mechanism for the actuation of the tested flexible guiding system and compliant connection. The presented development and preliminary testing of the high-precision long-stroke Slit Change Mechanism for the SPICE Instrument are considered fully successful such that future tests considering the full Slit Change Mechanism can be performed, with the gained confidence, directly on a Qualification Model. The selected linear Slit Change Mechanism design concept, consisting of a flexible guiding system driven by a hermetically sealed linear drive mechanism, is considered validated for the specific application of the SPICE instrument, with great potential for other special applications where contamination and high precision positioning are dominant design drivers.

  7. Cross-validation of commercial enzyme-linked immunosorbent assay and radioimmunoassay for porcine C-peptide concentration measurements in non-human primate serum.

    PubMed

    Gresch, Sarah C; Mutch, Lucas A; Janecek, Jody L; Hegstad-Davies, Rebecca L; Graham, Melanie L

    2017-09-01

    C-peptide concentration is widely used as a marker of insulin secretion and is especially relevant in evaluating islet graft function following transplantation, because its measurement is not confounded by the presence of exogenous insulin. To address the shortage of human islet donors, the use of porcine islets has been proposed as a possible solution and the stringent pig-to-non-human primate (NHP) model is often the most relevant for pre-clinical evaluation of the potential for diabetes reversal resulting from an islet xenograft. The Millipore radioimmunoassay (RIA) was exclusively used to measure porcine C-peptide (PCP) until 2013 when the assay was discontinued and subsequently a commercially available enzyme-linked immunosorbent assay (ELISA) from Mercodia has been widely adopted. Both assays have been used in pre-clinical trials evaluating the therapeutic potential of xenograft products in reversing diabetes in the pig-to-NHP model, to interpret data in a comparable way it may be useful to perform a harmonization of C-peptide measurements. We performed a method comparison by determining the PCP concentration in 620 serum samples collected from 20 diabetic cynomolgus macaques transplanted with adult porcine islets. All analyses were performed according to manufacturer instructions. With both assays, we demonstrated an acceptable detection limit, precision, and recovery. Linearity of the ELISA met acceptance criteria at all concentrations tested while linearity of the RIA only met acceptance criteria at five of the eight concentrations tested. The RIA had a detection limit of 0.16 ng/mL, and recovery ranged from 82% to 96% and met linearity acceptance criteria at 0.35 ng/mL and from 0.78 to 2.33 ng/mL. The ELISA had a detection limit of 0.03 ng/mL, and recovery ranged from 81% to 115% and met linearity acceptance criteria from 0.08 to 0.85 ng/mL. Both assays had intra-assay precision <11% and inter-assay precision <14%. PCP concentration measured by ELISA demonstrated a significant correlation with RIA (R 2 =.9721, P<.0001). This strong correlation supports use of the regression equation y=2.029x+0.0897 to transform ELISA data to RIA or inversely y=0.4930x-0.0456 to convert RIA data to ELISA for direct comparison between assays in the concentration range of 0-3.0 ng/mL. Measured C-peptide concentration was lower with the ELISA than with the RIA; individual measurements plotted against the averages of the pair demonstrated that the variability from the mean strongly depended on increasing concentration. Porcine C-peptide can be reliably measured in NHP serum using the Mercodia ELISA, making this assay interchangeable with the Millipore RIA. Inherent differences in antibody affinity and calibration factors may explain the lower ELISA values as compared to the RIA; however without access to a traceable reference standard, it is not possible to determine which assay is most accurate. Regression modeling resulted in a correction factor appropriate for conversion of ELISA data to RIA-equivalent data facilitating comparison of assay results longitudinally and between groups. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Generation and multi-octave shaping of mid-infrared intense single-cycle pulses

    NASA Astrophysics Data System (ADS)

    Krogen, Peter; Suchowski, Haim; Liang, Houkun; Flemens, Noah; Hong, Kyung-Han; Kärtner, Franz X.; Moses, Jeffrey

    2017-03-01

    The generation of intense mid-infrared (mid-IR) optical pulses with customizable shape and spectra spanning a multiple-octave range of vibrational frequencies is an elusive technological capability. While some recent approaches to mid-IR supercontinuum generation—such as filamentation, multicolour four-wave-mixing and optical rectification—have successfully generated broad spectra, no process has been identified for achieving complex pulse shaping at the generation step. The adiabatic frequency converter allows for a one-to-one transfer of spectral phase through nonlinear frequency conversion over a larger-than-octave-spanning range and with an overall linear phase transfer function. Here, we show that we can convert shaped near-infrared (near-IR) pulses to shaped, energetic, multi-octave-spanning mid-IR pulses lasting only 1.2 optical cycles, and extendable to the sub-cycle regime. We expect this capability to enable a new class of precisely controlled nonlinear interactions in the mid-IR spectral range, from nonlinear vibrational spectroscopy to strong light-matter interactions and single-shot remote sensing.

  9. Determination of ragaglitazar, a novel dual acting peroxisome proliferator-activated receptor (PPAR) alpha and -gamma agonist, in human plasma by high-performance liquid chromatography coupled with tandem mass spectrometry.

    PubMed

    Andersen, Michael P; Nielsen, Karin K

    2003-05-05

    A sensitive and specific LC/MS/MS method has been developed and validated for determination of ragaglitazar (NNC 61-0029 or DRF 2725) in human plasma. After solid-phase extraction (SPEC((R)) PLUS C(8)) of plasma, separation was performed on a Symmetry Shield RP8 column (mobile phase: acetonitrile: 10 mM ammonium acetate, pH 5.6 (40:60 v/v)). Two ranges were validated having LLOQs of either 0.500 or 100 ng/ml and linearity up to either 500 or 50000 ng/ml. The intra-assay precision and accuracy were 1.1% to 15.7% and 85.8% to 118.2% (range 0.500-500 ng/ml) and 2.0% to 8.8% and 92.9% to 104.8% (range 100-50000 ng/ml). The method was applied for determination of ragaglitazar in plasma from phase 1 and 2 clinical studies.

  10. Evaluation of Small Mass Spectrometer Systems

    NASA Technical Reports Server (NTRS)

    Arkin, C. Richard; Griffin, Timothy P.; Ottens, Andrew K.; Diaz, Jorge A.; Follistein, Duke W.; Adams, Fredrick W.; Helms, William R.; Voska, N. (Technical Monitor)

    2002-01-01

    This work is aimed at understanding the aspects of designing a miniature mass spectrometer (MS) system. A multitude of commercial and government sectors, such as the military, environmental agencies and industrial manufacturers of semiconductors, refrigerants, and petroleum products, would find a small, portable, rugged and reliable MS system beneficial. Several types of small MS systems are evaluated and discussed, including linear quadrupole, quadrupole ion trap, time of flight and sector. The performance of each system in terms of accuracy, precision, limits of detection, response time, recovery time, scan rate, volume and weight is assessed. A performance scale is setup to rank each systems and an overall performance score is given to each system. All experiments involved the analysis of hydrogen, helium, oxygen and argon in a nitrogen background with the concentrations of the components of interest ranging from 0-5000 part-per-million (ppm). The relative accuracies of the systems vary from < 1% to approx. 40% with an average below 10%. Relative precisions varied from 1% to 20%, with an average below 5%. The detection limits had a large distribution, ranging from 0.2 to 170 ppm. The systems had a diverse response time ranging from 4 s to 210 s as did the recovery time with a 6 s to 210 s distribution. Most instruments had scan times near, 1 s, however one instrument exceeded 13 s. System weights varied from 9 to 52 kg and sizes from 15 x 10(exp 3)cu cm to 110 x 10(exp 3) cu cm.

  11. Reliable and sensitive determination of dutasteride in human plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Contractor, Pritesh; Kurani, Hemal; Guttikar, Swati; Shrivastav, Pranav S

    2013-09-01

    An accurate and precise method was developed and validated using LC-MS/MS to quantify dutasteride in human plasma. The analyte and dutasteride-13C6 as internal standard (IS) were extracted from 300 μL plasma volume using methyl tert-butyl ether-n-hexane (80:20, v/v). Chromatographic analysis was performed on a Gemini C18 (150 × 4.6 mm, 5 µm) column using acetonitrile-5 mm ammonium formate, pH adjusted to 4.0 with formic acid (85:15, v/v) as the mobile phase. Tandem mass spectrometry in positive ionization mode was used to quantify dutasteride by multiple reaction monitoring. The entire data processing was done using Watson LIMS(TM) software, which provided excellent data integrity and high throughput with improved operational efficiency. The calibration curve was linear in the range of 0.1-25 ng/mL, with intra-and inter-batch values for accuracy and precision (coefficient of variation) ranging from 95.8 to 104.0 and from 0.7 to 5.3%, respectively. The mean overall recovery across quality controls was ≥95% for the analyte and IS, while the interference of matrix expressed as IS-normalized matrix factors ranged from 1.01 to 1.02. The method was successfully applied to support a bioequivalence study of 0.5 mg dutasteride capsules in 24 healthy subjects. Assay reproducibility was demonstrated by reanalysis of 103 incurred samples. Copyright © 2013 John Wiley & Sons, Ltd.

  12. An accuracy improvement method for the topology measurement of an atomic force microscope using a 2D wavelet transform.

    PubMed

    Yoon, Yeomin; Noh, Suwoo; Jeong, Jiseong; Park, Kyihwan

    2018-05-01

    The topology image is constructed from the 2D matrix (XY directions) of heights Z captured from the force-feedback loop controller. For small height variations, nonlinear effects such as hysteresis or creep of the PZT-driven Z nano scanner can be neglected and its calibration is quite straightforward. For large height variations, the linear approximation of the PZT-driven Z nano scanner fail and nonlinear behaviors must be considered because this would cause inaccuracies in the measurement image. In order to avoid such inaccuracies, an additional strain gauge sensor is used to directly measure displacement of the PZT-driven Z nano scanner. However, this approach also has a disadvantage in its relatively low precision. In order to obtain high precision data with good linearity, we propose a method of overcoming the low precision problem of the strain gauge while its feature of good linearity is maintained. We expect that the topology image obtained from the strain gauge sensor showing significant noise at high frequencies. On the other hand, the topology image obtained from the controller output showing low noise at high frequencies. If the low and high frequency signals are separable from both topology images, the image can be constructed so that it is represented with high accuracy and low noise. In order to separate the low frequencies from high frequencies, a 2D Haar wavelet transform is used. Our proposed method use the 2D wavelet transform for obtaining good linearity from strain gauge sensor and good precision from controller output. The advantages of the proposed method are experimentally validated by using topology images. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Evaluation of Beckman Coulter DxI 800 immunoassay system using clinically oriented performance goals.

    PubMed

    Akbas, Neval; Schryver, Patricia G; Algeciras-Schimnich, Alicia; Baumann, Nikola A; Block, Darci R; Budd, Jeffrey R; Gaston, S J Stephen; Klee, George G

    2014-11-01

    We evaluated the analytical performance of 24 immunoassays using the Beckman Coulter DxI 800 immunoassay systems at Mayo Clinic, Rochester, MN for trueness, precision, detection limits, linearity, and consistency (across instruments and reagent lots). Clinically oriented performance goals were defined using the following methods: trueness-published desirable accuracy limits, precision-published desirable biologic variation; detection limits - 0.1 percentile of patient test values, linearity - 50% of total error, and consistency-percentage test values crossing key decision points. Local data were collected for precision, linearity, and consistency. Data were provided by Beckman Coulter, Inc. for trueness and detection limits. All evaluated assays except total thyroxine were within the proposed goals for trueness. Most of the assays met the proposed goals for precision (86% of intra-assay results and 75% of inter-assay results). Five assays had more than 15% of the test results below the minimum detection limits. Carcinoembryonic antigen, total thyroxine and free triiodothyronine exceeded the proposed goals of ±6.3%, ±5% and ±5.7% for dilution linearity. All evaluated assays were within the proposed goals for instrument consistency. Lot-to-lot consistency results for cortisol, ferritin and total thyroxine exceeded the proposed goals of 3.3%, 11.4% and 7% at one medical decision level, while vitamin B12 exceeded the proposed goals of 5.2% and 3.8% at two decision levels. The Beckman Coulter DxI 800 immunoassay system meets most of these proposed goals, even though these clinically focused performance goals represent relatively stringent limits. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Efficient calculation of cosmological neutrino clustering in the non-linear regime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Archidiacono, Maria; Hannestad, Steen, E-mail: archi@phys.au.dk, E-mail: sth@phys.au.dk

    2016-06-01

    We study in detail how neutrino perturbations can be followed in linear theory by using only terms up to l =2 in the Boltzmann hierarchy. We provide a new approximation to the third moment and demonstrate that the neutrino power spectrum can be calculated to a precision of better than ∼ 5% for masses up to ∼ 1 eV and k ∼< 10 h /Mpc. The matter power spectrum can be calculated far more precisely and typically at least a factor of a few better than with existing approximations. We then proceed to study how the neutrino power spectrum canmore » be reliably calculated even in the non-linear regime by using the non-linear gravitational potential, sourced by dark matter overdensities, as it is derived from semi-analytic methods based on N -body simulations in the Boltzmann evolution hierarchy. Our results agree extremely well with results derived from N -body simulations that include cold dark matter and neutrinos as independent particles with different properties.« less

  15. Molecular weight distribution of polysaccharides from edible seaweeds by high-performance size-exclusion chromatography (HPSEC).

    PubMed

    Gómez-Ordóñez, Eva; Jiménez-Escrig, Antonio; Rupérez, Pilar

    2012-05-15

    Biological properties of polysaccharides from seaweeds are related to their composition and structure. Many factors such as the kind of sugar, type of linkage or sulfate content of algal biopolymers exert an influence in the relationship between structure and function. Besides, the molecular weight (MW) also plays an important role. Thus, a simple, reliable and fast HPSEC method with refractive index detection was developed and optimized for the MW estimation of soluble algal polysaccharides. Chromatogram shape and repeatability of retention time was considerably improved when sodium nitrate was used instead of ultrapure water as mobile phase. Pullulan and dextran standards of different MW were used for method calibration and validation. Also, main polysaccharide standards from brown (alginate, fucoidan, laminaran) and red seaweeds (kappa- and iota-carrageenan) were used for quantification and method precision and accuracy. Relative standard deviation (RSD) of repeatability for retention time, peak areas and inter-day precision was below 0.7%, 2.5% and 2.6%, respectively, which indicated good repeatability and precision. Recoveries (96.3-109.8%) also showed its fairly good accuracy. Regarding linearity, main polysaccharide standards from brown or red seaweeds showed a highly satisfactory correlation coefficient (r>0.999). Moreover, a good sensitivity was shown, with corresponding limits of detection and quantitation in mg/mL of 0.05-0.21 and 0.16-0.31, respectively. The method was applied to the MW estimation of standard algal polysaccharides, as well as to the soluble polysaccharide fractions from the brown seaweed Saccharina latissima and the red Mastocarpus stellatus, respectively. Although distribution of molecular weight was broad, the good repeatability for retention time provided a good precision in MW estimation of polysaccharides. Water- and alkali-soluble fractions from S. latissima ranged from very high (>2400 kDa) to low MW compounds (<6 kDa); this high heterogeneity could be attributable to the complex polysaccharide composition of brown algae. Regarding M. stellatus, sulfated galactans followed a descending order of MW (>1400 kDa to <10 kDa), related to the different solubility of carrageenans in red seaweeds. In summary, the method developed allows for the molecular weight analysis of seaweed polysaccharides with very good precision, accuracy, linearity and sensitivity within a short time. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Automated landmark extraction for orthodontic measurement of faces using the 3-camera photogrammetry methodology.

    PubMed

    Deli, Roberto; Di Gioia, Eliana; Galantucci, Luigi Maria; Percoco, Gianluca

    2010-01-01

    To set up a three-dimensional photogrammetric scanning system for precise landmark measurements, without any physical contact, using a low-cost and noninvasive digital photogrammetric solution, for supporting several necessity in clinical orthodontics and/or surgery diagnosis. Thirty coded targets were directly applied onto the subject's face on the soft tissue landmarks, and then, 3 simultaneous photos were acquired using photogrammetry, at room light conditions. For comparison, a dummy head was digitized both with a photogrammetric technique and with the laser scanner Minolta Vivid 910i (Konica Minolta, Tokyo, Japan). The precise measurement of the landmarks is ranged between 0.017 and 0.029 mm. The system automatically measures spatial position of face landmarks, from which distances and angles can be obtained. The facial measurements were compared with those done using laser scanning and manual caliper. The adopted method gives higher precision than the others (0.022-mm mean value on points and 0.038-mm mean value on linear distances on a dummy head), is simple, and can be used easily as a standard routine. The study demonstrated the validity of photogrammetry for accurate digitization of human face landmarks. This research points out the potential of this low-cost photogrammetry approach for medical digitization.

  17. Kalman filter-based tracking of moving objects using linear ultrasonic sensor array for road vehicles

    NASA Astrophysics Data System (ADS)

    Li, Shengbo Eben; Li, Guofa; Yu, Jiaying; Liu, Chang; Cheng, Bo; Wang, Jianqiang; Li, Keqiang

    2018-01-01

    Detection and tracking of objects in the side-near-field has attracted much attention for the development of advanced driver assistance systems. This paper presents a cost-effective approach to track moving objects around vehicles using linearly arrayed ultrasonic sensors. To understand the detection characteristics of a single sensor, an empirical detection model was developed considering the shapes and surface materials of various detected objects. Eight sensors were arrayed linearly to expand the detection range for further application in traffic environment recognition. Two types of tracking algorithms, including an Extended Kalman filter (EKF) and an Unscented Kalman filter (UKF), for the sensor array were designed for dynamic object tracking. The ultrasonic sensor array was designed to have two types of fire sequences: mutual firing or serial firing. The effectiveness of the designed algorithms were verified in two typical driving scenarios: passing intersections with traffic sign poles or street lights, and overtaking another vehicle. Experimental results showed that both EKF and UKF had more precise tracking position and smaller RMSE (root mean square error) than a traditional triangular positioning method. The effectiveness also encourages the application of cost-effective ultrasonic sensors in the near-field environment perception in autonomous driving systems.

  18. Estimation of stature using anthropometry of feet and footprints in a Western Australian population.

    PubMed

    Hemy, Naomi; Flavel, Ambika; Ishak, Nur-Intaniah; Franklin, Daniel

    2013-07-01

    The aim of the study is to develop accurate stature estimation models for a contemporary Western Australian population from measurements of the feet and footprints. The sample comprises 200 adults (90 males, 110 females). A stature measurement, three linear measurements from each foot and bilateral footprints were collected from each subject. Seven linear measurements were then extracted from each print. Prior to data collection, a precision test was conducted to determine the repeatability of measurement acquisition. The primary data were then analysed using a range of parametric statistical tests. Results show that all foot and footprint measurements were significantly (P < 0.01-0.001) correlated with stature and estimation models were formulated with a prediction accuracy of ± 4.673 cm to ± 6.926 cm. Left foot length was the most accurate single variable in the simple linear regressions (males: ± 5.065 cm; females: ± 4.777 cm). This study provides viable alternatives for estimating stature in a Western Australian population that are equivalent to established standards developed from foot bones. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  19. Evaluation of empirical rule of linearly correlated peptide selection (ERLPS) for proteotypic peptide-based quantitative proteomics.

    PubMed

    Liu, Kehui; Zhang, Jiyang; Fu, Bin; Xie, Hongwei; Wang, Yingchun; Qian, Xiaohong

    2014-07-01

    Precise protein quantification is essential in comparative proteomics. Currently, quantification bias is inevitable when using proteotypic peptide-based quantitative proteomics strategy for the differences in peptides measurability. To improve quantification accuracy, we proposed an "empirical rule for linearly correlated peptide selection (ERLPS)" in quantitative proteomics in our previous work. However, a systematic evaluation on general application of ERLPS in quantitative proteomics under diverse experimental conditions needs to be conducted. In this study, the practice workflow of ERLPS was explicitly illustrated; different experimental variables, such as, different MS systems, sample complexities, sample preparations, elution gradients, matrix effects, loading amounts, and other factors were comprehensively investigated to evaluate the applicability, reproducibility, and transferability of ERPLS. The results demonstrated that ERLPS was highly reproducible and transferable within appropriate loading amounts and linearly correlated response peptides should be selected for each specific experiment. ERLPS was used to proteome samples from yeast to mouse and human, and in quantitative methods from label-free to O18/O16-labeled and SILAC analysis, and enabled accurate measurements for all proteotypic peptide-based quantitative proteomics over a large dynamic range. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Quantification of endocrine disruptors and pesticides in water by gas chromatography-tandem mass spectrometry. Method validation using weighted linear regression schemes.

    PubMed

    Mansilha, C; Melo, A; Rebelo, H; Ferreira, I M P L V O; Pinho, O; Domingues, V; Pinho, C; Gameiro, P

    2010-10-22

    A multi-residue methodology based on a solid phase extraction followed by gas chromatography-tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC-MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Voltammetric Determination of Penicillamine Using a Carbon Paste Electrode Modified with Multiwall Carbon Nanotubes In the Presence of Methyldopa as a Mediator.

    PubMed

    Safari, Fardin; Keyvanfard, Mohsen; Karimi-Maleh, Hassan; Alizad, Khadijeh

    2017-01-01

    A multiwall carbon nanotubes-modified carbon paste electrode (MWCNTs/MCPE) was fabricated and used to study the electrooxidation of penicillamine (PA) by electrochemical methods in the presence of methyldopa (MDOP) as a homogeneous mediator. The electrochemical oxidation of PA on the new sensor has been carefully studied. The kinetic parameters such as electron transfer coefficient, α, and catalytic reaction rate constant, K / h , were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of PA showed a linear dependent on the PA concentrations and linear calibration curves were obtained in the ranges of 0.2-250.0 µM of PA concentration with square wave voltammetry (SWV) method. The detection limit (3σ) was determined as 0.1 µM. This sensor was also examined as a fast, selective, simple and precise new sensor for voltammetric determination of PA in real samples such as drug and urine.

  2. Validated spectrofluorimetric method for the determination of tamsulosin in spiked human urine, pure and pharmaceutical preparations.

    PubMed

    Karasakal, A; Ulu, S T

    2014-05-01

    A novel, sensitive and selective spectrofluorimetric method was developed for the determination of tamsulosin in spiked human urine and pharmaceutical preparations. The proposed method is based on the reaction of tamsulosin with 1-dimethylaminonaphthalene-5-sulfonyl chloride in carbonate buffer pH 10.5 to yield a highly fluorescent derivative. The described method was validated and the analytical parameters of linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, recovery and robustness were evaluated. The proposed method showed a linear dependence of the fluorescence intensity on drug concentration over the range 1.22 × 10(-7) to 7.35 × 10(-6)  M. LOD and LOQ were calculated as 1.07 × 10(-7) and 3.23 × 10(-7)  M, respectively. The proposed method was successfully applied for the determination of tamsulosin in pharmaceutical preparations and the obtained results were in good agreement with those obtained using the reference method. Copyright © 2013 John Wiley & Sons, Ltd.

  3. A laser spectrometer and wavemeter for pulsed lasers

    NASA Technical Reports Server (NTRS)

    Mckay, J. A.; Laufer, P. M.; Cotnoir, L. J.

    1989-01-01

    The design, construction, calibration, and evaluation of a pulsed laser wavemeter and spectral analyzer are described. This instrument, called the Laserscope for its oscilloscope-like display of laser spectral structure, was delivered to NASA Langley Research Center as a prototype of a laboratory instrument. The key component is a multibeam Fizeau wedge interferometer, providing high (0.2 pm) spectral resolution and a linear dispersion of spectral information, ideally suited to linear array photodiode detectors. Even operating alone, with the classic order-number ambiguity of interferometers unresolved, this optical element will provide a fast, real-time display of the spectral structure of a laser output. If precise wavelength information is also desired then additional stages must be provided to obtain a wavelength measurement within the order-number uncertainty, i.e., within the free spectral range of the Fizeau wedge interferometer. A Snyder (single-beam Fizeau) wedge is included to provide this initial wavelength measurement. Difficulties in achieving the required wide-spectrum calibration limit the usefulness of this function.

  4. QUANTIFICATION OF GLYCYRRHIZIN BIOMARKER IN GLYCYRRHIZA GLABRA RHIZOME AND BABY HERBAL FORMULATIONS BY VALIDATED RP-HPTLC METHODS

    PubMed Central

    Alam, Prawez; Foudah, Ahmed I.; Zaatout, Hala H.; T, Kamal Y; Abdel-Kader, Maged S.

    2017-01-01

    Background: A simple and sensitive thin-layer chromatographic method has been established for quantification of glycyrrhizin in Glycyrrhiza glabra rhizome and baby herbal formulations by validated Reverse Phase HPTLC method. Materials and Methods: RP-HPTLC Method was carried out using glass coated with RP-18 silica gel 60 F254S HPTLC plates using methanol-water (7: 3 v/v) as mobile phase. Results: The developed plate was scanned and quantified densitometrically at 256 nm. Glycyrrhizin peaks from Glycyrrhiza glabra rhizome and baby herbal formulations were identified by comparing their single spot at Rf = 0.63 ± 0.01. Linear regression analysis revealed a good linear relationship between peak area and amount of glycyrrhizin in the range of 2000-7000 ng/band. Conclusion: The method was validated, in accordance with ICH guidelines for precision, accuracy, and robustness. The proposed method will be useful to enumerate the therapeutic dose of glycyrrhizin in herbal formulations as well as in bulk drug. PMID:28573236

  5. Autonomous Guidance of Agile Small-scale Rotorcraft

    NASA Technical Reports Server (NTRS)

    Mettler, Bernard; Feron, Eric

    2004-01-01

    This report describes a guidance system for agile vehicles based on a hybrid closed-loop model of the vehicle dynamics. The hybrid model represents the vehicle dynamics through a combination of linear-time-invariant control modes and pre-programmed, finite-duration maneuvers. This particular hybrid structure can be realized through a control system that combines trim controllers and a maneuvering control logic. The former enable precise trajectory tracking, and the latter enables trajectories at the edge of the vehicle capabilities. The closed-loop model is much simpler than the full vehicle equations of motion, yet it can capture a broad range of dynamic behaviors. It also supports a consistent link between the physical layer and the decision-making layer. The trajectory generation was formulated as an optimization problem using mixed-integer-linear-programming. The optimization is solved in a receding horizon fashion. Several techniques to improve the computational tractability were investigate. Simulation experiments using NASA Ames 'R-50 model show that this approach fully exploits the vehicle's agility.

  6. [Extracting THz absorption coefficient spectrum based on accurate determination of sample thickness].

    PubMed

    Li, Zhi; Zhang, Zhao-hui; Zhao, Xiao-yan; Su, Hai-xia; Yan, Fang

    2012-04-01

    Extracting absorption spectrum in THz band is one of the important aspects in THz applications. Sample's absorption coefficient has a complex nonlinear relationship with its thickness. However, as it is not convenient to measure the thickness directly, absorption spectrum is usually determined incorrectly. Based on the method proposed by Duvillaret which was used to precisely determine the thickness of LiNbO3, the approach to measuring the absorption coefficient spectra of glutamine and histidine in frequency range from 0.3 to 2.6 THz(1 THz = 10(12) Hz) was improved in this paper. In order to validate the correctness of this absorption spectrum, we designed a series of experiments to compare the linearity of absorption coefficient belonging to one kind amino acid in different concentrations. The results indicate that as agreed by Lambert-Beer's Law, absorption coefficient spectrum of amino acid from the improved algorithm performs better linearity with its concentration than that from the common algorithm, which can be the basis of quantitative analysis in further researches.

  7. Programmable motion of DNA origami mechanisms.

    PubMed

    Marras, Alexander E; Zhou, Lifeng; Su, Hai-Jun; Castro, Carlos E

    2015-01-20

    DNA origami enables the precise fabrication of nanoscale geometries. We demonstrate an approach to engineer complex and reversible motion of nanoscale DNA origami machine elements. We first design, fabricate, and characterize the mechanical behavior of flexible DNA origami rotational and linear joints that integrate stiff double-stranded DNA components and flexible single-stranded DNA components to constrain motion along a single degree of freedom and demonstrate the ability to tune the flexibility and range of motion. Multiple joints with simple 1D motion were then integrated into higher order mechanisms. One mechanism is a crank-slider that couples rotational and linear motion, and the other is a Bennett linkage that moves between a compacted bundle and an expanded frame configuration with a constrained 3D motion path. Finally, we demonstrate distributed actuation of the linkage using DNA input strands to achieve reversible conformational changes of the entire structure on ∼ minute timescales. Our results demonstrate programmable motion of 2D and 3D DNA origami mechanisms constructed following a macroscopic machine design approach.

  8. Programmable motion of DNA origami mechanisms

    PubMed Central

    Marras, Alexander E.; Zhou, Lifeng; Su, Hai-Jun; Castro, Carlos E.

    2015-01-01

    DNA origami enables the precise fabrication of nanoscale geometries. We demonstrate an approach to engineer complex and reversible motion of nanoscale DNA origami machine elements. We first design, fabricate, and characterize the mechanical behavior of flexible DNA origami rotational and linear joints that integrate stiff double-stranded DNA components and flexible single-stranded DNA components to constrain motion along a single degree of freedom and demonstrate the ability to tune the flexibility and range of motion. Multiple joints with simple 1D motion were then integrated into higher order mechanisms. One mechanism is a crank–slider that couples rotational and linear motion, and the other is a Bennett linkage that moves between a compacted bundle and an expanded frame configuration with a constrained 3D motion path. Finally, we demonstrate distributed actuation of the linkage using DNA input strands to achieve reversible conformational changes of the entire structure on ∼minute timescales. Our results demonstrate programmable motion of 2D and 3D DNA origami mechanisms constructed following a macroscopic machine design approach. PMID:25561550

  9. Temperature and neuronal circuit function: compensation, tuning and tolerance.

    PubMed

    Robertson, R Meldrum; Money, Tomas G A

    2012-08-01

    Temperature has widespread and diverse effects on different subcellular components of neuronal circuits making it difficult to predict precisely the overall influence on output. Increases in temperature generally increase the output rate in either an exponential or a linear manner. Circuits with a slow output tend to respond exponentially with relatively high Q(10)s, whereas those with faster outputs tend to respond in a linear fashion with relatively low temperature coefficients. Different attributes of the circuit output can be compensated by virtue of opposing processes with similar temperature coefficients. At the extremes of the temperature range, differences in the temperature coefficients of circuit mechanisms cannot be compensated and the circuit fails, often with a reversible loss of ion homeostasis. Prior experience of temperature extremes activates conserved processes of phenotypic plasticity that tune neuronal circuits to be better able to withstand the effects of temperature and to recover more rapidly from failure. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Temporal Stability of GPS Transmitter Group Delay Variations.

    PubMed

    Beer, Susanne; Wanninger, Lambert

    2018-05-29

    The code observable of global navigation satellite systems (GNSS) is influenced by group delay variations (GDV) of transmitter and receiver antennas. For the Global Positioning System (GPS), the variations can sum up to 1 m in the ionosphere-free linear combination and thus can significantly affect precise code applications. The contribution of the GPS transmitters can amount to 0.8 m peak-to-peak over the entire nadir angle range. To verify the assumption of their time-invariance, we determined daily individual satellite GDV for GPS transmitter antennas over a period of more than two years. Dual-frequency observations of globally distributed reference stations and their multipath combination form the basis for our analysis. The resulting GPS GDV are stable on the level of a few centimeters for C1, P2, and for the ionosphere-free linear combination. Our study reveals that the inconsistencies of the GDV of space vehicle number (SVN) 55 with respect to earlier studies are not caused by temporal instabilities, but are rather related to receiver properties.

  11. Voltammetric Determination of Penicillamine Using a Carbon Paste Electrode Modified with Multiwall Carbon Nanotubes In the Presence of Methyldopa as a Mediator

    PubMed Central

    Safari, Fardin; Keyvanfard, Mohsen; Karimi-Maleh, Hassan; Alizad, Khadijeh

    2017-01-01

    A multiwall carbon nanotubes-modified carbon paste electrode (MWCNTs/MCPE) was fabricated and used to study the electrooxidation of penicillamine (PA) by electrochemical methods in the presence of methyldopa (MDOP) as a homogeneous mediator. The electrochemical oxidation of PA on the new sensor has been carefully studied. The kinetic parameters such as electron transfer coefficient, α, and catalytic reaction rate constant, K/h, were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of PA showed a linear dependent on the PA concentrations and linear calibration curves were obtained in the ranges of 0.2-250.0 µM of PA concentration with square wave voltammetry (SWV) method. The detection limit (3σ) was determined as 0.1 µM. This sensor was also examined as a fast, selective, simple and precise new sensor for voltammetric determination of PA in real samples such as drug and urine. PMID:29201090

  12. Implementing DBS methodology for the determination of Compound A in monkey blood: GLP method validation and investigation of the impact of blood spreading on performance.

    PubMed

    Fan, Leimin; Lee, Jacob; Hall, Jeffrey; Tolentino, Edward J; Wu, Huaiqin; El-Shourbagy, Tawakol

    2011-06-01

    This article describes validation work for analysis of an Abbott investigational drug (Compound A) in monkey whole blood with dried blood spots (DBS). The impact of DBS spotting volume on analyte concentration was investigated. The quantitation range was between 30.5 and 10,200 ng/ml. Accuracy and precision of quality controls, linearity of calibration curves, matrix effect, selectivity, dilution, recovery and multiple stabilities were evaluated in the validation, and all demonstrated acceptable results. Incurred sample reanalysis was performed with 57 out of 58 samples having a percentage difference (versus the mean value) less than 20%. A linear relationship between the spotting volume and the spot area was drawn. The influence of spotting volume on concentration was discussed. All validation results met good laboratory practice acceptance requirements. Radial spreading of blood on DBS cards can be a factor in DBS concentrations at smaller spotting volumes.

  13. Analysis of Mycosporine-Like Amino Acids in Selected Algae and Cyanobacteria by Hydrophilic Interaction Liquid Chromatography and a Novel MAA from the Red Alga Catenella repens

    PubMed Central

    Hartmann, Anja; Becker, Kathrin; Karsten, Ulf; Remias, Daniel; Ganzera, Markus

    2015-01-01

    Mycosporine-like amino acids (MAAs), a group of small secondary metabolites found in algae, cyanobacteria, lichens and fungi, have become ecologically and pharmacologically relevant because of their pronounced UV-absorbing and photo-protective potential. Their analytical characterization is generally achieved by reversed phase HPLC and the compounds are often quantified based on molar extinction coefficients. As an alternative approach, in our study a fully validated hydrophilic interaction liquid chromatography (HILIC) method is presented. It enables the precise quantification of several analytes with adequate retention times in a single run, and can be coupled directly to MS. Excellent linear correlation coefficients (R2 > 0.9991) were obtained, with limit of detection (LOD) values ranging from 0.16 to 0.43 µg/mL. Furthermore, the assay was found to be accurate (recovery rates from 89.8% to 104.1%) and precise (intra-day precision: 5.6%, inter-day precision ≤6.6%). Several algae were assayed for their content of known MAAs like porphyra-334, shinorine, and palythine. Liquid chromatography-mass spectrometry (LC-MS) data indicated a novel compound in some of them, which could be isolated from the marine species Catenella repens and structurally elucidated by nuclear magnetic resonance spectroscopy (NMR) as (E)-3-hydroxy-2-((5-hydroxy-5-(hydroxymethyl)-2-methoxy-3-((2-sulfoethyl)amino)cyclohex-2-en-1-ylidene)amino) propanoic acid, a novel MAA called catenelline. PMID:26473886

  14. Analysis of Mycosporine-Like Amino Acids in Selected Algae and Cyanobacteria by Hydrophilic Interaction Liquid Chromatography and a Novel MAA from the Red Alga Catenella repens.

    PubMed

    Hartmann, Anja; Becker, Kathrin; Karsten, Ulf; Remias, Daniel; Ganzera, Markus

    2015-10-09

    Mycosporine-like amino acids (MAAs), a group of small secondary metabolites found in algae, cyanobacteria, lichens and fungi, have become ecologically and pharmacologically relevant because of their pronounced UV-absorbing and photo-protective potential. Their analytical characterization is generally achieved by reversed phase HPLC and the compounds are often quantified based on molar extinction coefficients. As an alternative approach, in our study a fully validated hydrophilic interaction liquid chromatography (HILIC) method is presented. It enables the precise quantification of several analytes with adequate retention times in a single run, and can be coupled directly to MS. Excellent linear correlation coefficients (R² > 0.9991) were obtained, with limit of detection (LOD) values ranging from 0.16 to 0.43 µg/mL. Furthermore, the assay was found to be accurate (recovery rates from 89.8% to 104.1%) and precise (intra-day precision: 5.6%, inter-day precision ≤6.6%). Several algae were assayed for their content of known MAAs like porphyra-334, shinorine, and palythine. Liquid chromatography-mass spectrometry (LC-MS) data indicated a novel compound in some of them, which could be isolated from the marine species Catenella repens and structurally elucidated by nuclear magnetic resonance spectroscopy (NMR) as (E)-3-hydroxy-2-((5-hydroxy-5-(hydroxymethyl)-2-methoxy-3-((2-sulfoethyl)amino)cyclohex-2-en-1-ylidene)amino) propanoic acid, a novel MAA called catenelline.

  15. Application of high-precision two-way ranging to Galileo Earth-1 encounter navigation

    NASA Technical Reports Server (NTRS)

    Pollmeier, V. M.; Thurman, S. W.

    1992-01-01

    The application of precision two-way ranging to orbit determination with relatively short data arcs is investigated for the Galileo spacecraft's approach to its first Earth encounter (December 8, 1990). Analysis of previous S-band (2.3-GHz) ranging data acquired from Galileo indicated that under good signal conditions submeter precision and 10-m ranging accuracy were achieved. It is shown that ranging data of sufficient accuracy, when acquired from multiple stations, can sense the geocentric angular position of a distant spacecraft. A range data filtering technique, in which explicit modeling of range measurement bias parameters for each station pass is utilized, is shown to largely remove the systematic ground system calibration errors and transmission media effects from the Galileo range measurements, which would otherwise corrupt the angle-finding capabilities of the data. The accuracy of the Galileo orbit solutions obtained with S-band Doppler and precision ranging were found to be consistent with simple theoretical calculations, which predicted that angular accuracies of 0.26-0.34 microrad were achievable. In addition, the navigation accuracy achieved with precision ranging was marginally better than that obtained using delta-differenced one-way range (delta DOR), the principal data type that was previously used to obtain spacecraft angular position measurements operationally.

  16. Supercritical fluid extraction of 13-cis retinoic acid and its photoisomers from selected pharmaceutical dosage forms.

    PubMed

    Simmons, B R; Chukwumerije, O; Stewart, J T

    1997-11-01

    13-Cis retinoic acid (Accutane) was extracted from a cream, gel, capsule and beadlet dosage from using supercritical carbon dioxide modified with 5% methanol as the mobile phase. The pump pressure and the extraction chamber and restrictor temperature were experimentally optimized at 325 atm and 45 degrees C, respectively. A 2.5-min static and 5-min dynamic extraction time were used. The supercritical fluid extraction (SFE) eluent was trapped in methanol, injected into the high-performance liquid chromatographic (HPLC) system, and quantitated by ultraviolet detection at 360 nm. Application of the SFE method to spiked placebo dosage forms gave 13-cis retinoic acid recoveries of 98.8, 98.9, 98.8 and 100% for the cream, gel, capsule and beadlet, respectively, with R.S.D.s in the range 0.6-0.9% (n = 4). Inter-day percent error and precision of the extraction were 1.1-2.0 and 0.2-2.4% (n = 3), respectively, and intra-day percent error and precision were 1.0-3.0 and 0.3-2.1% (n = 8), respectively. Percent error and precision data for spiked celite samples in the 0.05-1.0 microgram ml-1 range were 0.59-4.75 and 1.8-2.1% (n = 3), respectively. The extraction method was applied to commercial 13-cis retinoic acid dosage forms and the results compared to unextracted samples. Linear regression analysis of concentration versus peak height gave a correlation coefficient of 0.9991 with a slope of 7.468 and a y-intercept of 0.1923. The percent error and precision data were 1.3-5.3 and 0.2-1.5% (n = 4), respectively. The photoisomers of 13-cis retinoic acid were also extracted with the method and recoveries of 90.4-92.4% with R.S.D.s of 1.5-3.4% were obtained (n = 4).

  17. Analytical Method Development and Validation for the Simultaneous Estimation of Abacavir and Lamivudine by Reversed-phase High-performance Liquid Chromatography in Bulk and Tablet Dosage Forms.

    PubMed

    Raees Ahmad, Sufiyan Ahmad; Patil, Lalit; Mohammed Usman, Mohammed Rageeb; Imran, Mohammad; Akhtar, Rashid

    2018-01-01

    A simple rapid, accurate, precise, and reproducible validated reverse phase high performance liquid chromatography (HPLC) method was developed for the determination of Abacavir (ABAC) and Lamivudine (LAMI) in bulk and tablet dosage forms. The quantification was carried out using Symmetry Premsil C18 (250 mm × 4.6 mm, 5 μm) column run in isocratic way using mobile phase comprising methanol: water (0.05% orthophosphoric acid with pH 3) 83:17 v/v and a detection wavelength of 245 nm and injection volume of 20 μl, with a flow rate of 1 ml/min. In the developed method, the retention times of ABAC and LAMI were found to be 3.5 min and 7.4 min, respectively. The method was validated in terms of linearity, precision, accuracy, limits of detection, limits of quantitation, and robustness in accordance with the International Conference on Harmonization guidelines. The assay of the proposed method was found to be 99% - 101%. The recovery studies were also carried out and mean % recovery was found to be 99% - 101%. The % relative standard deviation from reproducibility was found to be <2%. The proposed method was statistically evaluated and can be applied for routine quality control analysis of ABAC and LAMI in bulk and in tablet dosage form. Attempts were made to develop RP-HPLC method for simultaneous estimation of Abacavir and Lamivudine for the RP-HPLC method. The developed method was validated according to the ICH guidelines. The linearity, precision, range, robustness were within the limits as specified by the ICH guidelines. Hence the method was found to be simple, accurate, precise, economic and reproducible. So the proposed methods can be used for the routine quality control analysis of Abacavir and Lamivudine in bulk drug as well as in formulations. Abbreviations Used: HPLC: High-performance liquid chromatography, UV: Ultraviolet, ICH: International Conference on Harmonization, ABAC: Abacavir, LAMI: Lamivudine, HIV: Human immunodeficiency virus, AIDS: Acquired immunodeficiency syndrome, NRTI: Nucleoside reverse transcriptase inhibitors, ARV: Antiretroviral, RSD: Relative standard deviation, RT: Retention time, SD: Standard deviation.

  18. High efficiency machining technology and equipment for edge chamfer of KDP crystals

    NASA Astrophysics Data System (ADS)

    Chen, Dongsheng; Wang, Baorui; Chen, Jihong

    2016-10-01

    Potassium dihydrogen phosphate (KDP) is a type of nonlinear optical crystal material. To Inhibit the transverse stimulated Raman scattering of laser beam and then enhance the optical performance of the optics, the edges of the large-sized KDP crystal needs to be removed to form chamfered faces with high surface quality (RMS<5 nm). However, as the depth of cut (DOC) of fly cutting is usually several, its machining efficiency is too low to be accepted for chamfering of the KDP crystal as the amount of materials to be removed is in the order of millimeter. This paper proposes a novel hybrid machining method, which combines precision grinding with fly cutting, for crackless and high efficiency chamfer of KDP crystal. A specialized machine tool, which adopts aerostatic bearing linear slide and aerostatic bearing spindle, was developed for chamfer of the KDP crystal. The aerostatic bearing linear slide consists of an aerostatic bearing guide with linearity of 0.1 μm/100mm and a linear motor to achieve linear feeding with high precision and high dynamic performance. The vertical spindle consists of an aerostatic bearing spindle with the rotation accuracy (axial) of 0.05 microns and Fork type flexible connection precision driving mechanism. The machining experiment on flying and grinding was carried out, the optimize machining parameters was gained by a series of experiment. Surface roughness of 2.4 nm has been obtained. The machining efficiency can be improved by six times using the combined method to produce the same machined surface quality.

  19. Derivative spectrophotometric method for simultaneous determination of clindamycin phosphate and tretinoin in pharmaceutical dosage forms

    PubMed Central

    2013-01-01

    A derivative spectrophotometric method was proposed for the simultaneous determination of clindamycin and tretinoin in pharmaceutical dosage forms. The measurement was achieved using the first and second derivative signals of clindamycin at (1D) 251 nm and (2D) 239 nm and tretinoin at (1D) 364 nm and (2D) 387 nm. The proposed method showed excellent linearity at both first and second derivative order in the range of 60–1200 and 1.25–25 μg/ml for clindamycin phosphate and tretinoin respectively. The within-day and between-day precision and accuracy was in acceptable range (CV<3.81%, error<3.20%). Good agreement between the found and added concentrations indicates successful application of the proposed method for simultaneous determination of clindamycin and tretinoin in synthetic mixtures and pharmaceutical dosage form. PMID:23575006

  20. Sensitive high-performance liquid chromatography/mass spectrometry method for determination of steviol in rat plasma.

    PubMed

    Wang, L Z; Goh, B C; Fan, L; Lee, H S

    2004-01-01

    The main toxicological concern of stevioside, a highly potent sweetener from S. rebaudiana, is its main metabolite, steviol. To determine very low levels of steviol in in vivo experiments, a sensitive liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS) method was developed for quantifying steviol in rat plasma after oral administration of a single dose of stevioside (0.5 g/kg). The sample preparation uses liquid-liquid extraction with tert-butyl methyl ether in an acidic environment. The retention time of steviol was 10.5 min. The assay was linear over the range 2-1000 ng/mL with a lower limit of detection of 1 ng/mL. The intra- and inter-day precision were <5 and <7%, respectively, and the accuracy was in the range 95-108%. The steviol concentration profile in rat plasma was determined. Copyright 2003 John Wiley & Sons, Ltd.