Hinchliffe, Edward; Rudge, James; Reed, Paul
2016-07-01
Measurement of vitamin A (retinol) and E (alpha-tocopherol) in UK clinical laboratories is currently performed exclusively by high-performance liquid chromatography with ultraviolet detection. We investigated whether retinol and alpha-tocopherol could be measured simultaneously by liquid chromatography tandem mass spectrometry. Serum samples (100 μL) were extracted using Isolute + Supported Liquid Extraction plates. Chromatography was performed on a Phenomenex Kinetex Biphenyl 2.6 μm, 50 × 2.1 mm column, and liquid chromatography tandem mass spectrometry on a Waters Acquity TQD. Injection-to-injection time was 4.3 min. The assay was validated according to published guidelines. Patient samples were used to compare liquid chromatography tandem mass spectrometry and high-performance liquid chromatography with ultraviolet detection methods. For retinol and alpha-tocopherol, respectively, the assay was linear up to 6.0 and 80.0 μmol/L, and lower limit of quantification was 0.07 and 0.26 μmol/L. Intra and interassay imprecision were within desirable analytical specifications. Analysis of quality control material aligned to NIST SRM 968e, and relative spiked recovery from human serum, both yielded results within 15% of target values. Method comparison with high-performance liquid chromatography with ultraviolet detection methodology demonstrated a negative bias for retinol and alpha-tocopherol by the liquid chromatography tandem mass spectrometry method. Analysis of United Kingdom National External Quality Assurance Scheme samples yielded mean bias from the target value of +3.0% for retinol and -11.2% for alpha-tocopherol. We have developed a novel, high-throughput method for extraction of retinol and alpha-tocopherol from human serum followed by simultaneous quantitation by liquid chromatography tandem mass spectrometry. The method offers a rapid, sensitive, specific and cost-effective alternative to high-performance liquid chromatography with ultraviolet detection methodology, and is suitable for routine clinical monitoring of patients predisposed to fat-soluble vitamin malabsorption. © The Author(s) 2015.
Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu
2016-07-01
An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin
2017-12-01
A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Markó, Lajos; Molnár, Gergo Attila; Wagner, Zoltán; Koszegi, Tamás; Matus, Zoltán; Mohás, Márton; Kuzma, Mónika; Szijártó, István András; Wittmann, István
2008-01-13
Hypertension as well as type 2 diabetes mellitus is a major factor in population mortality. Both diseases damage the endothelium, the early sign of which is microalbuminuria, which can be screened by dipstick and can be diagnosed by using immuno-based and high performance liquid chromatography methods. Using high performance liquid chromatography, the non-immunoreactive albumin can be detected as well. The authors aimed at the examination of albuminuria in the case of immunonephelometrically negative patients with high performance liquid chromatography, in diabetic and hypertensive and non-diabetic hypertensive populations. The authors also wanted to compare the present (albumin-creatinine ratio: male: > or =2.5 mg/mmol, female: > or =3.5 mg/mmol) and a new criteria of the Heart Outcomes Prevention Evaluation study (patients without diabetes: immunological method, > or =0.7 mg/mmol; high performance liquid chromatography, > or =3.1 mg/mmol; individuals with diabetes: immunological method, > or =1.4 mg/mmol; high performance liquid chromatography, > or =5.2 mg/mmol) of microalbuminuria. Examination of fresh urines of 469 microalbuminuria negative patients by dipstick were performed by immunonephelometry. Patients, who were microalbuminuria negative by immunonephelometry as well, were further analyzed by high performance liquid chromatography using the Accumintrade mark Kit, based on size-exclusion chromatography. Three times higher albuminuria were found with high performance liquid chromatography than with immunonephelometry. The intraindividual coefficient of variation did not differ in the two methods (37 +/- 31% vs. 40 +/- 31%, p = 0.869; immunonephelometry vs. high performance liquid chromatography; mean +/- standard deviation). Using the present criteria for microalbuminuria, 43% of immunonephelometrically negative patients proved to be microalbuminuric by high performance liquid chromatography. Using the new criteria of the Heart Outcomes Prevention Evaluation study, the rate of microalbuminuria positivity among the immunonephelometrically negative patients decreased to 14.5% by high performance liquid chromatography and the decrease in the number of microalbuminuria positive cases by high performance liquid chromatography could be observed mainly in the diabetic and hypertensive group (49% vs. 7.5%), while slighter decrease could be observed in the non-diabetic hypertensive group (37% vs. 26.5%). Applying the traditional criteria, the strongest predictor was the male gender by the logistic regression analysis. In 28% of microalbuminuria negative patients by immunonephelometry the diagnosis of microalbuminuria can be established using high performance liquid chromatography. Almost in one-third of microalbuminuria negative patients by immunonephelometry the diagnosis of microalbuminuria can be established by high performance liquid chromatography for which diagnosis three constitutive urine examinations are still needed. New criteria determined by the Heart Outcomes Prevention Evaluation study can be used neither in case of diabetic and hypertensive patients, nor in the case of non-diabetic hypertensive patients. The gender as the most important predictor of microalbuminuria cannot be ignored.
Tao, Lingyan; Zhang, Qing; Wu, Yongjiang; Liu, Xuesong
2016-12-01
In this study, a fast and effective high-performance liquid chromatography method was developed to obtain a fingerprint chromatogram and quantitative analysis simultaneously of four indexes including gallic acid, chlorogenic acid, albiflorin and paeoniflorin of the traditional Chinese medicine Moluodan Concentrated Pill. The method was performed by using a Waters X-bridge C 18 reversed phase column on an Agilent 1200S high-performance liquid chromatography system coupled with diode array detection. The mobile phase of the high-performance liquid chromatography method was composed of 20 mmol/L phosphate solution and acetonitrile with a 1 mL/min eluent velocity, under a detection temperature of 30°C and a UV detection wavelength of 254 nm. After the methodology validation, 16 batches of Moluodan Concentrated Pill were analyzed by this high-performance liquid chromatography method and both qualitative and quantitative evaluation results were achieved by similarity analysis, principal component analysis and hierarchical cluster analysis. The results of these three chemometrics were in good agreement and all indicated that batch 10 and batch 16 showed significant differences with the other 14 batches. This suggested that the developed high-performance liquid chromatography method could be applied in the quality evaluation of Moluodan Concentrated Pill. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Counter-current motion in counter-current chromatography.
Ito, Yoichiro
2014-12-12
After the CCC2012 meeting, I have received an e-mail regarding the terminology of "Countercurrent Chromatography". It stated that the term "Countercurrent" is a misnomer, because its stationary phase is motionless in the column and that the method should be renamed as liquid-liquid separations or centrifugal separations. However, it was found that these names are already used for various other techniques as found via Google search. The term "Countercurrent Chromatography" was originally made after two preparative methods of Countercurrent distribution and liquid Chromatography, both having no countercurrent motion in the column. However, it is surprising to find that this F1 hybrid method "Countercurrent Chromatography" can clearly exhibit countercurrent motion within the separation column in both hydrodynamic and hydrostatic equilibrium systems. This justifies that "Countercurrent Chromatography" is a proper term for this chromatographic method. Published by Elsevier B.V.
Challal, Soura; Queiroz, Emerson Ferreira; Debrus, Benjamin; Kloeti, Werner; Guillarme, Davy; Gupta, Mahabir Prashad; Wolfender, Jean-Luc
2015-11-01
In natural product research, the isolation of biomarkers or bioactive compounds from complex natural extracts represents an essential step for de novo identification and bioactivity assessment. When pure natural products have to be obtained in milligram quantities, the chromatographic steps are generally labourious and time-consuming. In this respect, an efficient method has been developed for the reversed-phase gradient transfer from high-performance liquid chromatography to medium-performance liquid chromatography for the isolation of pure natural products at the level of tens of milligrams from complex crude natural extracts. The proposed method provides a rational way to predict retention behaviour and resolution at the analytical scale prior to medium-performance liquid chromatography, and guarantees similar performances at both analytical and preparative scales. The optimisation of the high-performance liquid chromatography separation and system characterisation allows for the prediction of the gradient at the medium-performance liquid chromatography scale by using identical stationary phase chemistries. The samples were introduced in medium-performance liquid chromatography using a pressure-resistant aluminium dry load cell especially designed for this study to allow high sample loading while maintaining a maximum achievable flow rate for the separation. The method has been validated with a mixture of eight natural product standards. Ultraviolet and evaporative light scattering detections were used in parallel for a comprehensive monitoring. In addition, post-chromatographic mass spectrometry detection was provided by high-throughput ultrahigh-performance liquid chromatography time-of-flight mass spectrometry analyses of all fractions. The processing of all liquid chromatography-mass spectrometry data in the form of an medium-performance liquid chromatography x ultra high-performance liquid chromatography time-of-flight mass spectrometry matrix enabled an efficient localisation of the compounds of interest in the generated fractions. The methodology was successfully applied for the separation of three different plant extracts that contain many diverse secondary metabolites. The advantages and limitations of this approach and the theoretical chromatographic background that rules such as liquid chromatography gradient transfer are presented from a practical viewpoint. Georg Thieme Verlag KG Stuttgart · New York.
Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun
2017-10-13
A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.
Development of quality assurance methods for epoxy graphite prepreg
NASA Technical Reports Server (NTRS)
Chen, J. S.; Hunter, A. B.
1982-01-01
Quality assurance methods for graphite epoxy/prepregs were developed. Liquid chromatography, differential scanning calorimetry, and gel permeation chromatography were investigated. These methods were applied to a second prepreg system. The resin matrix formulation was correlated with mechanical properties. Dynamic mechanical analysis and fracture toughness methods were investigated. The chromatography and calorimetry techniques were all successfully developed as quality assurance methods for graphite epoxy prepregs. The liquid chromatography method was the most sensitive to changes in resin formulation. The were also successfully applied to the second prepreg system.
Suzuki, Shigeru
2014-01-01
The techniques and measurement methods developed in the Environmental Survey and Monitoring of Chemicals by Japan’s Ministry of the Environment, as well as a large amount of knowledge archived in the survey, have led to the advancement of environmental analysis. Recently, technologies such as non-target liquid chromatography/high resolution mass spectrometry and liquid chromatography with micro bore column have further developed the field. Here, the general strategy of a method developed for the liquid chromatography/mass spectrometry (LC/MS) analysis of environmental chemicals with a brief description is presented. Also, a non-target analysis for the identification of environmental pollutants using a provisional fragment database and “MsMsFilter,” an elemental composition elucidation tool, is presented. This analytical method is shown to be highly effective in the identification of a model chemical, the pesticide Bendiocarb. Our improved micro-liquid chromatography injection system showed substantially enhanced sensitivity to perfluoroalkyl substances, with peak areas 32–71 times larger than those observed in conventional LC/MS. PMID:26819891
Ma, Jing; Hou, Xiaofang; Zhang, Bing; Wang, Yunan; He, Langchong
2014-03-01
In this study, a new"heart-cutting" two-dimensional liquid chromatography method for the simultaneous determination of carbohydrate contents in milk powder was presented. In this two dimensional liquid chromatography system, a Venusil XBP-C4 analysis column was used in the first dimension ((1)D) as a pre-separation column, a ZORBAX carbohydrates analysis column was used in the second dimension ((2)D) as a final-analysis column. The whole process was completed in less than 35min without a particular sample preparation procedure. The capability of the new two dimensional HPLC method was demonstrated in the determination of carbohydrates in various brands of milk powder samples. A conventional one dimensional chromatography method was also proposed. The two proposed methods were both validated in terms of linearity, limits of detection, accuracy and precision. The comparison between the results obtained with the two methods showed that the new and completely automated two dimensional liquid chromatography method is more suitable for milk powder sample because of its online cleanup effect involved. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
[Development of methods for determining acrylamide in food products by gas-liquid chromatography].
Bessonov, V V; Malinkin, A D; Perederiaev, O I; Bogachuk, M N; Volkovich, S V; Medvedev, Iu V
2011-01-01
The method of determination of acrylamide in various food (milk powder, potato chips, instant coffee) by gas-liquid chromatography after pre-bromination was developed. Studies have shown the possibility of using bromination of acrylamide to give it the necessary properties for better extraction, purification and detection. Also revealed the possibility of qualitative and quantitative determine a acrylamide in food by gas-liquid chromatography with detection by electron capture detector.
Method 8321B describes procedures for preparation and analysis of solid, aqueous liquid, drinking water and wipe samples using high performance liquid chromatography and mass spectrometry for extractable non-volatile compounds.
Tisdall, P A; DeYoung, D R; Roberts, G D; Anhalt, J P
1982-01-01
Identification of routine mycobacterial isolates by gas-liquid chromatography profile analysis was performed on 335 strains received at the Mayo Clinic over a 10-month period. Comparison of identification by gas-liquid chromatography versus conventional biochemical profiles was made. The two methods agreed on the identification of 320 isolates, with gas-liquid chromatography profiling making eight errors and biochemical profiling making four errors. In three cases, discrepancies could not be resolved. PMID:6811612
ERIC Educational Resources Information Center
Owens, Janel E.; Zimmerman, Laura B.; Gardner, Michael A.; Lowe, Luis E.
2016-01-01
Analysis of whiskey samples prepared by a green microextraction technique, dispersive liquid-liquid microextraction (DLLME), before analysis by a qualitative gas chromatography-mass spectrometry (GC/MS) method, is described as a laboratory experiment for an upper division instrumental methods of analysis laboratory course. Here, aroma compounds in…
Tassi, Marco; De Vos, Jelle; Chatterjee, Sneha; Sobott, Frank; Bones, Jonathan; Eeltink, Sebastiaan
2018-01-01
The characterization of biotherapeutics represents a major analytical challenge. This review discusses the current state-of-the-art in analytical technologies to profile biopharma products under native conditions, i.e., the protein three dimensional conformation is maintained during liquid chromatographic analysis. Native liquid-chromatographic modes that are discussed include aqueous size-exclusion chromatography, hydrophobic interaction chromatography, and ion-exchange chromatography. Infusion conditions and the possibilities and limitations to hyphenate native liquid chromatography to mass spectrometry are discussed. Furthermore, the applicability of native liquid-chromatography methods and intact mass spectrometry analysis for the characterization of monoclonal antibodies and antibody-drug conjugates is discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Damm, Irina; Enger, Eileen; Chrubasik-Hausmann, Sigrun; Schieber, Andreas; Zimmermann, Benno F
2016-08-01
Fast methods for the extraction and analysis of various secondary metabolites from cocoa products were developed and optimized regarding speed and separation efficiency. Extraction by pressurized liquid extraction is automated and the extracts are analyzed by rapid reversed-phase ultra high-performance liquid chromatography and normal-phase high-performance liquid chromatography methods. After extraction, no further sample treatment is required before chromatographic analysis. The analytes comprise monomeric and oligomeric flavanols, flavonols, methylxanthins, N-phenylpropenoyl amino acids, and phenolic acids. Polyphenols and N-phenylpropenoyl amino acids are separated in a single run of 33 min, procyanidins are analyzed by normal-phase high-performance liquid chromatography within 16 min, and methylxanthins require only 6 min total run time. A fourth method is suitable for phenolic acids, but only protocatechuic acid was found in relevant quantities. The optimized methods were validated and applied to 27 dark chocolates, one milk chocolate, two cocoa powders and two food supplements based on cocoa extract. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-05
... was required for gas chromatography with mass selective detection (GC/MSD) but not for liquid... detection (LOD = 0.01) and a gas liquid chromatography (GLC) method with a flame photometric detection (LOD... quantification by high performance liquid chromatography with tandem mass spectrometric detection (HPLC/MS/MS...
Zonta, F; Stancher, B
1985-07-19
A high-performance liquid chromatographic method for determining phylloquinone (vitamin K1) in soy bean oils is described. Resolution of vitamin K1 from interfering peaks of the matrix was obtained after enzymatic digestion, extraction and liquid-solid chromatography on alumina. An isocratic reversed-phase chromatography with UV detection was used in the final stage. The quantitation was carried out by the standard addition method, and the recovery of the whole procedure was 88.2%.
Wang, Jing; Pan, Hefang; Liu, Zhengzheng; Ge, Fei
2009-03-20
A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 microm, 50 mm x 2.1mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0-103.4%, with the RSD<15%. The calibration curves for alkylphenols were linear within the range of 0.01-0.4 microg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 microg/kg.
An automated method for the determination of carbendazim in water that combines high-performance immunoaffinity chromatography (HPIAC), high-performance liquid chromatography (HPLC) in the reversed-phase mode, and detection by either UV-Vis diode array detector (DAD) spectroscopy...
Bailey, C; Kitchen, I
1985-06-01
A method is described for the separation of proenkephalin products using gradient high-performance liquid chromatography preceded by Sep-Pak chromatography. Samples can be assayed simply by use of a modified mouse vas deferens bioassay which is sufficiently sensitive for most applications. The preliminary Sep-Pak chromatography method excludes alpha-neoendorphin and the dynorphins and thus provides a suitable procedure for separation of prodynorphin and proenkephalin products.
Peterson, R. E.; Grove, M. D.
1983-01-01
A method was developed for the production and purification of xanthomegnin from Penicillium viridicatum (NRRL 6430) cultured on rice at 15°C for 29 days. Liquid-liquid extraction followed by high-pressure liquid chromatography afforded 440 mg of crystalline xanthomegnin per kg of rice. PMID:6881966
A qualitative method using 2,4-dinitrophenylhydrazine (DNPH) derivatization followed by analysis with liquid chromatography (LC)/negative ion-electrospray mass spectrometry (MS) was developed for identifying polar aldehydes and ketones in ozonated drinking water. This method offe...
Analysis of selected herbicide metabolites in surface and ground water of the United States
Scribner, E.A.; Thurman, E.M.; Zimmerman, L.R.
2000-01-01
One of the primary goals of the US Geological Survey (USGS) Laboratory in Lawrence, Kansas, is to develop analytical methods for the analysis of herbicide metabolites in surface and ground water that are vital to the study of herbicide fate and degradation pathways in the environment. Methods to measure metabolite concentrations from three major classes of herbicides - triazine, chloroacetanilide and phenyl-urea - have been developed. Methods for triazine metabolite detection cover nine compounds: six compounds are detected by gas chromatography/mass spectrometry; one is detected by high-performance liquid chromatography with diode-array detection; and eight are detected by liquid chromatography/mass spectrometry. Two metabolites of the chloroacetanilide herbicides - ethane sulfonic acid and oxanilic acid - are detected by high-performance liquid chromatography with diode-array detection and liquid chromatography/mass spectrometry. Alachlor ethane sulfonic acid also has been detected by solid-phase extraction and enzyme-linked immunosorbent assay. Six phenylurea metabolites are all detected by liquid chromatography/mass spectrometry; four of the six metabolites also are detected by gas chromatography/mass spectrometry. Additionally, surveys of herbicides and their metabolites in surface water, ground water, lakes, reservoirs, and rainfall have been conducted through the USGS laboratory in Lawrence. These surveys have been useful in determining herbicide and metabolite occurrence and temporal distribution and have shown that metabolites may be useful in evaluation of non-point-source contamination. Copyright (C) 2000 Elsevier Science B.V.
Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai
2016-04-01
In this study, a method coupling turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry was developed for analyzing the lignans in Magnoliae Flos. By the online pretreatment of turbulent flow chromatography solid-phase extraction, the impurities removal and analytes concentration were automatically processed, and the lignans were separated rapidly and well. Seven lignans of Magnoliae Flos including epieudesmin, magnolin, 1-irioresinol-B-dimethyl ether, epi-magnolin, fargesin aschantin, and demethoxyaschantin were identified by comparing their retention behavior, UV spectra, and mass spectra with those of reference substances or literature data. The developed method was validated, and the good results showed that the method was not only automatic and rapid, but also accurate and reliable. The turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry method holds a high potential to become an effective method for the quality control of lignans in Magnoliae Flos and a useful tool for the analysis of other complex mixtures. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zou, Nan; Chen, Ronghua; Qin, Yuhong; Song, Shuangyu; Tang, Xinglin; Pan, Canping
2016-09-01
Analytical methods based on multiplug filtration cleanup coupled with pulse glow discharge-ion mobility spectrometry and liquid chromatography tandem mass spectrometry were developed for the analysis of tricaine mesylate residue in fish and fish-raising water samples. A silica fiber holder and an appropriate new interface were designed to make the direct introduction of the fiber into the pulse glow discharge-ion mobility spectrometry introduction mechanism. The multiplug filtration cleanup method with adsorption mixtures was optimized for the determination of tricaine mesylate in fish samples. Good linear relationships were obtained by the two methods. For fish samples, limits of detection were 6 and 0.6 μg/kg by ion mobility spectrometry and liquid chromatography with tandem mass spectrometry, respectively. The matrix effect of the established liquid chromatography tandem mass spectrometry method was negligible for fish samples but that of the ion mobility spectrometry method was not. The two methods were compared. The ion mobility spectrometry system could be used a rapid screening tool on site with the advantage of rapidity, simplicity, and portability, and the liquid chromatography tandem mass spectrometry system could be used for validation in laboratory conditions with the advantage of lower limit of detection, stability, and precision. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Borovcová, Lucie; Pauk, Volodymyr; Lemr, Karel
2018-05-01
New psychoactive substances represent serious social and health problem as tens of new compounds are detected in Europe annually. They often show structural proximity or even isomerism, which complicates their analysis. Two methods based on ultra high performance supercritical fluid chromatography and ultra high performance liquid chromatography with mass spectrometric detection were validated and compared. A simple dilute-filter-and-shoot protocol utilizing propan-2-ol or methanol for supercritical fluid or liquid chromatography, respectively, was proposed to detect and quantify 15 cathinones and phenethylamines in human urine. Both methods offered fast separation (<3 min) and short total analysis time. Precision was well <15% with a few exceptions in liquid chromatography. Limits of detection in urine ranged from 0.01 to 2.3 ng/mL, except for cathinone (5 ng/mL) in supercritical fluid chromatography. Nevertheless, this technique distinguished all analytes including four pairs of isomers, while liquid chromatography was unable to resolve fluoromethcathinone regioisomers. Concerning matrix effects and recoveries, supercritical fluid chromatography produced more uniform results for different compounds and at different concentration levels. This work demonstrates the performance and reliability of supercritical fluid chromatography and corroborates its applicability as an alternative tool for analysis of new psychoactive substances in biological matrixes. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
APPLICATION OF A SPRAY DEPOSITION METHOD FOR REVERSED PHASE LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
Four coal gasification wastewater samples were analyzed for nonvolatile and polar organics by liquid chromatography-mass spectrometry (LC/MS). Samples were separated on a reverse phase liquid chromatographic column using an aqueous solvent as the eluant. A special spray depositio...
This research was conducted in cooperation with EPA Region 4 in Athens, GA to develop a method to analyze selected pyrethroid pesticides using Reverse Phase-High Pressure Liquid Chromatography (HPLC). This HPLC method will aid researchers in separating and identifying these py...
This document is a standardized single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection and quantification of cyanotoxins (combined intracellular and extracellular) in ambient freshwaters.
Yang, Bichao; Xin, Huaxia; Wang, Feier; Cai, Jianfeng; Liu, Yanfang; Fu, Qing; Jin, Yu; Liang, Xinmiao
2017-08-01
As a common traditional Chinese medicine, Fructus Arctii has important clinical medical values. Its main components are lignans, which are difficult to separate and analyze because of the complex composition, similar chemical structures, and close properties. In this study, an off-line two-dimensional supercritical fluid chromatography/reversed-phase liquid chromatography method, as well as an effective sample pretreatment method based on hydrophilic interaction chromatography material, was developed to enrich the minor lignan fractions and obtain high-purity compounds. In total, 12 high-purity compounds were isolated from Fructus Arctii. Their structures were identified by using high-resolution mass spectrometry and nuclear magnetic resonance spectroscopy, which showed that all were lignans and that most of them were isomers. The results demonstrated the effective off-line two-dimensional supercritical fluid chromatography/reversed-phase liquid chromatography method for the purification of lignans from Fructus Arctii. The separation protocol established here will be beneficial for the separation of complex samples from other kinds of natural products. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
High Performance Liquid Chromatography of Vitamin A: A Quantitative Determination.
ERIC Educational Resources Information Center
Bohman, Ove; And Others
1982-01-01
Experimental procedures are provided for the quantitative determination of Vitamin A (retinol) in food products by analytical liquid chromatography. Standard addition and calibration curve extraction methods are outlined. (SK)
Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai
2017-01-01
In this paper, by coupling reversed phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC), a two-dimensional liquid chromatography system was developed for separation and identification of the active ingredients in Gardenia jasminoides Ellis (GJE). By applying the semi-preparative C18 column as the first dimension and the core-shell column as the second dimension, a total of 896 peaks of GJE were separated. Among the 896 peaks, 16 active ingredients including geniposide, gardenoside, gardoside, etc. were identified by mass spectrometry analysis. The results indicated that the proposed two-dimensional RPLC/HILIC system was an effective method for the analysis of GJE and might hold a high potential to become a useful tool for analysis of other complex mixtures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Wang, Yifan; Li, Haiyan; Yang, Zhen; Zhang, Weijie; Hua, Jia
2017-12-01
To explore why the use of furfural as a transformer oil-paper insulation aging characteristic is problematic in real world application, we developed a method for the simultaneous determination of furfural, furoic acid, and maleic acid in transformer oil by reversed-phase vortex-assisted liquid-liquid microextraction combined with high-performance liquid chromatography. The conditions for the proposed method were optimized, and the obtained extract can be directly analyzed by high-performance liquid chromatography. The detection limits (signal-to-noise ratio = 3) of the method ranged from 1.0 to 4.6 μg/L, the enrichment factors for furfural, furoic acid, maleic acid, and fumaric acid were 4.6, 25.1, 15.6, and 17.5, respectively, and the recovery rates for three analytes (fumaric acid was undetected) range from 82.1 to 106.2%. The contents of furfural, furoic acid, and maleic acid resulted from accelerated aging of transformer insulation oil-paper were measured using the present method for the first time, and the aging samples were analyzed by liquid chromatography with mass spectrometry for the identification of furoic acid and maleic acid in the aging transformer oil samples. Using the optimal method, the target products of samples at different aging time were tracked and measured. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Chunhui; Ning, Ke; Zhang, Wenwen; Guo, Yuanjie; Chen, Jun; Liang, Chen
2013-04-01
Increased attention is currently being directed towards the potential negative effects of antibiotics and other PPCPs discharged into the aquatic environment via municipal WWTP secondary effluents. A number of analytical methods, such as high performance liquid chromatography technologies, including a high performance liquid chromatography-fluorescence method (HPLC-FLD), high performance liquid chromatography-UV detection method (HPLC-UV) and high performance liquid chromatography-mass spectrometry method (HPLC-MS), have been suggested as determination technologies for antibiotic residues in water. In this study, we implement a HPLC-MS/MS combined method to detect and analyze antibiotics in WWTP secondary effluent and apply a horizontal subsurface flow constructed wetland (CW) as an advanced wastewater treatment for removing antibiotics in the WWTP secondary effluent. The results show that there were 2 macrolides, 2 quinolones and 5 sulfas in WWTP secondary effluent among all the 22 antibiotics considered. After the CW advanced treatment, the concentration removal efficiencies and removal loads of 9 antibiotics were 53-100% and 0.004-0.7307 μg m(-2) per day, respectively.
USDA-ARS?s Scientific Manuscript database
A method for the highly sensitive determination of 2-, 3- and 4- nitrophenols was developed using reverse-phase high-performance liquid chromatography (RP-HPLC) with a UV photodiode array detector. Using a reverse-phase column and 40% aqueous acetonitrile as an eluent (i.e. isocratic elution), the i...
A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...
This research was conducted in cooperation with EPA Region 4 in Athens, GA to develop a method to analyze selected pyrethroid pesticides using Reverse Phase-High Pressure Liquid Chromatography (HPLC). This HPLC method will aid researchers in separating and identifying these pyre...
This document is a standardized, single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection of cyanotoxins—microsystins and nodularin (combined intracellular and extracellular)—in ambient freshwaters.
A method using reversed phase high performance liquid chromatography/electrospray ionization-mass spectrometric (RP-LC/ESI-MS) method has been developed to confirm the identity of dansylated derivatives of cysteine and glutathione, and their respective dimers. Cysteine, GSH, CSSC...
A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-24
... for plant commodities) are both gas liquid chromatography (GLC) methods with electron capture... analytical methodology using liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) detection...-aminopropane]) using gas chromatography (GC) have been submitted to the EPA. In addition, a new validated...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Hok, S; Alcaraz, A
Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limitmore » of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.« less
Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...
Baghdady, Yehia Z; Schug, Kevin A
2016-01-01
Accurate and specific analysis of target molecules in complex biological matrices remains a significant challenge, especially when ultra-trace detection limits are required. Liquid chromatography with mass spectrometry is often the method of choice for bioanalysis. Conventional sample preparation and clean-up methods prior to the analysis of biological fluids such as liquid-liquid extraction, solid-phase extraction, or protein precipitation are time-consuming, tedious, and can negatively affect target recovery and detection sensitivity. An alternative or complementary strategy is the use of an off-line or on-line in situ derivatization technique. In situ derivatization can be incorporated to directly derivatize target analytes in their native biological matrices, without any prior sample clean-up methods, to substitute or even enhance the extraction and preconcentration efficiency of these traditional sample preparation methods. Designed appropriately, it can reduce the number of sample preparation steps necessary prior to analysis. Moreover, in situ derivatization can be used to enhance the performance of the developed liquid chromatography with mass spectrometry-based bioanalysis methods regarding stability, chromatographic separation, selectivity, and ionization efficiency. This review presents an overview of the commonly used in situ derivatization techniques coupled to liquid chromatography with mass spectrometry-based bioanalysis to guide and to stimulate future research. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
USDA-ARS?s Scientific Manuscript database
Analysis of 9 macrolides is presented, including tulathromycin A (Draxxin), in beef, poultry and pork muscle with a simple multi-residue extraction and analysis method using high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The extraction method inv...
USDA-ARS?s Scientific Manuscript database
A method for the identification and quantification of citrus limonoid glucosides in juices based upon high performance liquid chromatography (HPLC) separation coupled to post-column reaction with Ehrlichs’s reagent has been developed. This method utilizes a phenyl stationary phase and an isocratic ...
ERIC Educational Resources Information Center
Smith, Eugene T.; Hill, Marc
2011-01-01
In this laboratory exercise, students develop a LabVIEW-controlled high-performance liquid chromatography system utilizing a data acquisition device, two pumps, a detector, and fraction collector. The programming experience involves a variety of methods for interface communication, including serial control, analog-to-digital conversion, and…
Yang, Lili; Jin, Fen; Zhang, Peng; Zhang, Yanxin; Wang, Jian; Shao, Hua; Jin, Maojun; Wang, Shanshan; Zheng, Lufei; Wang, Jing
2015-09-30
A simple analytical method was developed for the simultaneous analysis of 18 perfluorinated compounds (PFCs) in edible oil. The target compounds were extracted by acetonitrile, purified by gel permeation chromatography (GPC) and dispersive solid-phase extraction (DSPE) using graphitized carbon black (GCB) and octadecyl (C18), and analyzed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ES-MS/MS) in negative ion mode. Recovery studies were performed at three fortification levels. The average recoveries of all target PFCs ranged from 60 to 129%, with an acceptable relative standard deviation (RSD) (1-20%, n = 3). The method detection limits (MDLs) ranged from 0.004 to 0.4 μg/kg, which was significantly improved compared with the existing liquid-liquid extraction and cleanup method. The method was successfully applied for the analysis of all target PFCs in edible oil samples collected from markets in Beijing, China, and the results revealed that C6-C10 perfluorocarboxylic acid (PFCAs) and C7 perfluorosulfonic acid PFSAs were the major PFCs detected in oil samples.
GLC analysis of base composition of RNA and DNA hydrolysates
NASA Technical Reports Server (NTRS)
Lakings, D. B.; Gehreke, C. W.
1971-01-01
Various methods used for the analysis of the base composition of RNA and DNA hydrolysates are presented. The methods discussed are: (1) ion-exchange chromatography, (2) paper chromatography, (3) paper electrophoresis, (4) thin layer chromatography, (5) paper chromatography and time of flight mass spectrometry, and (6) gas-liquid chromatography. The equipment required and the conditions for obtaining the best results with each method are described.
Wang, Yinan; Han, Fei; Song, Aihua; Wang, Miao; Zhao, Min; Zhao, Chunjie
2016-11-01
Cortex Fraxini is an important traditional Chinese medicine. In this work, a rapid and reliable homogenate extraction method was applied for the fast extraction for Cortex Fraxini, and the method was optimized by response surface methodology. Ultra high performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry and gas chromatography with mass spectrometry were established for the separation and characterization of the constituents of Cortex Fraxini. Liquid chromatography separation was conducted on a C 18 column (150 mm × 2.1 mm, 1.8 μm), and gas chromatography separation was performed on a capillary with a 5% phenyl-methylpolysiloxane stationary phase (30 m × 0.25 mm × 0.25 mm) by injection of silylated samples. According to the results, 33 chemical compounds were characterized by liquid chromatography with mass spectrometry, and 11 chemical compounds were characterized by gas chromatography with mass spectrometry, and coumarins were the major components characterized by both gas chromatography with mass spectrometry and liquid chromatography with mass spectrometry. The proposed homogenate extraction was an efficient and rapid method, and coumarins, phenylethanoid glycosides, iridoid glycosides, phenylpropanoids, and lignans were the main constituents of Cortex Fraxini. This work laid the foundation for further study of Cortex Fraxini and will be helpful for the rapid extraction and characterization of ingredients in other traditional Chinese medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Chromatography/Mass Spectrometry (GC/MS) 525.3 24 Carbofuran High-performance liquid chromatography (HPLC) with... (HPLC) with Post-Column Derivatization and Fluorescence Detection 6651 B 6651 B 6651 B-00. Heptachlor... Spectrometry (GC/MS) 525.3 24 Oxamyl High-performance liquid chromatography (HPLC) with post-column...
Isolation of Gregatin A from Phialophora gregata by Preparative High-Pressure Liquid Chromatography
Taylor, Scott L.; Peterson, Robert E.; Gray, Lynn E.
1985-01-01
A method was developed for the production and purification of gregatin A from Phialophora gregata NRRL 13198 cultured on rice at 20°C for 28 days. Liquid extraction followed by high-pressure liquid chromatography afforded 247.0 mg of crystalline gregatin A per kg of rice. PMID:16346936
Chen, Tao; Liu, Yongling; Zou, Denglang; Chen, Chen; You, Jinmao; Zhou, Guoying; Sun, Jing; Li, Yulin
2014-01-01
This study presents an efficient strategy based on liquid-liquid extraction, high-speed counter-current chromatography, and preparative HPLC for the rapid enrichment, separation, and purification of four anthraquinones from Rheum tanguticum. A new solvent system composed of petroleum ether/ethyl acetate/water (4:2:1, v/v/v) was developed for the liquid-liquid extraction of the crude extract from R. tanguticum. As a result, emodin, aloe-emodin, physcion, and chrysophanol were greatly enriched in the organic layer. In addition, an efficient method was successfully established to separate and purify the above anthraquinones by high-speed counter-current chromatography and preparative HPLC. This study supplies a new alternative method for the rapid enrichment, separation, and purification of emodin, aloe-emodin, physcione, and chrysophanol. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zoccali, Mariosimone; Barp, Laura; Beccaria, Marco; Sciarrone, Danilo; Purcaro, Giorgia; Mondello, Luigi
2016-02-01
Mineral oils, which are mainly composed of saturated hydrocarbons and aromatic hydrocarbons, are widespread food contaminants. Liquid chromatography coupled to gas chromatography with flame ionization detection represents the method of choice to determine these two families. However, despite the high selectivity of this technique, the presence of olefins (particularly squalene and its isomers) in some samples as in olive oils, does not allow the correct quantification of the mineral oil aromatic hydrocarbons fraction, requiring additional off-line tools to eliminate them. In the present research, a novel on-line liquid chromatography coupled to gas chromatography method is described for the determination of hydrocarbon contamination in edible oils. Two different liquid chromatography columns, namely a silica one (to retain the bulk of the matrix) and a silver-ion one (which better retains the olefins), were coupled in series to obtain the mineral oil aromatic hydrocarbons hump free of interfering peaks. Furthermore, the use of a simultaneous dual detection, flame ionization detector and triple quadrupole mass spectrometer allowed us not only to quantify the mineral oil contamination, but also to evaluate the presence of specific markers (i.e. hopanes) to confirm the petrogenic origin of the contamination. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Pauwels, Jochen; D'Autry, Ward; Van den Bossche, Larissa; Dewever, Cédric; Forier, Michel; Vandenwaeyenberg, Stephanie; Wolfs, Kris; Hoogmartens, Jos; Van Schepdael, Ann; Adams, Erwin
2012-02-23
Capsaicinoids, salicylic acid, methyl and ethyl salicylate, glycol monosalicylate, camphor and l-menthol are widely used in topical formulations to relieve local pain. For each separate compound or simple mixtures, quantitative analysis methods are reported. However, for a mixture containing all above mentioned active compounds, no assay methods were found. Due to the differing physicochemical characteristics, two methods were developed and optimized simultaneously. The non-volatile capsaicinoids, salicylic acid and glycol monosalicylate were analyzed with liquid chromatography following liquid-liquid extraction, whereas the volatile compounds were analyzed with static headspace-gas chromatography. For the latter method, liquid paraffin was selected as compatible dilution solvent. The optimized methods were validated in terms of specificity, linearity, accuracy and precision in a range of 80% to 120% of the expected concentrations. For both methods, peaks were well separated without interference of other compounds. Linear relationships were demonstrated with R² values higher than 0.996 for all compounds. Accuracy was assessed by performing replicate recovery experiments with spiked blank samples. Mean recovery values were all between 98% and 102%. Precision was checked at three levels: system repeatability, method precision and intermediate precision. Both methods were found to be acceptably precise at all three levels. Finally, the method was successfully applied to the analysis of some real samples (cutaneous sticks). Copyright © 2011 Elsevier B.V. All rights reserved.
Taguchi, Kaori; Fukusaki, Eiichiro; Bamba, Takeshi
2014-10-03
Chromatography techniques usually use a single state in the mobile phase, such as liquid, gas, or supercritical fluid. Chromatographers manage one of these techniques for their purpose but are sometimes required to use multiple methods, or even worse, multiple techniques when the target compounds have a wide range of chemical properties. To overcome this challenge, we developed a single method covering a diverse compound range by means of a "unified" chromatography which completely bridges supercritical fluid chromatography and liquid chromatography. In our method, the phase state was continuously changed in the following order; supercritical, subcritical and liquid. Moreover, the gradient of the mobile phase starting at almost 100% CO2 was replaced with 100% methanol at the end completely. As a result, this approach achieved further extension of the polarity range of the mobile phase in a single run, and successfully enabled the simultaneous analysis of fat- and water-soluble vitamins with a wide logP range of -2.11 to 10.12. Furthermore, the 17 vitamins were exceptionally separated in 4min. Our results indicated that the use of dense CO2 and the replacement of CO2 by methanol are practical approaches in unified chromatography covering diverse compounds. Additionally, this is a first report to apply the novel approach to unified chromatography, and can open another door for diverse compound analysis in a single chromatographic technique with single injection, single column and single system. Copyright © 2014. Published by Elsevier B.V.
Fan, Chen; Li, Nai; Cao, Xueli
2015-05-01
In-situ ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) method was developed as a pretreatment method for the detection of six chlorophenols (CPs) in honey samples. The hydrophobic ionic liquid [C4MIM][NTf2], formed in-situ by the hydrophilic ionic liquid [C4MIM][BF4] and the ion exchange reagent LiNTf2 was used as the microextractant solvent of CPs from honey sample. Then the enriched analytes were back-extracted into 40 μL of 0.14 M NaOH solution and finally subjected to analysis by high-performance liquid chromatography. The method showed low limit of detection of CPs, 0.8-3.2 μg/L and high enrichment factor, 34-65 with the recoveries range from 91.60% to 114.33%. The method is simple, rapid, environmentally friendly and with high extraction efficiency. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Ionic liquid stationary phases for gas chromatography.
Poole, Colin F; Poole, Salwa K
2011-04-01
This article provides a summary of the development of ionic liquids as stationary phases for gas chromatography beginning with early work on packed columns that established details of the retention mechanism and established working methods to characterize selectivity differences compared with molecular stationary phases through the modern development of multi-centered cation and cross-linked ionic liquids for high-temperature applications in capillary gas chromatography. Since there are many reviews on ionic liquids dealing with all aspects of their chemical and physical properties, the emphasis in this article is placed on the role of gas chromatography played in the design of ionic liquids of low melting point, high thermal stability, high viscosity, and variable selectivity for separations. Ionic liquids provide unprecedented opportunities for extending the selectivity range and temperature-operating range of columns for gas chromatography, an area of separation science that has otherwise been almost stagnant for over a decade. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Two-Dimensional Liquid Chromatography Analysis of Polystyrene/Polybutadiene Block Copolymers.
Lee, Sanghoon; Choi, Heejae; Chang, Taihyun; Staal, Bastiaan
2018-05-15
A detailed characterization of a commercial polystyrene/polybutadiene block copolymer material (Styrolux) was carried out using two-dimensional liquid chromatography (2D-LC). The Styrolux is prepared by statistical linking reaction of two different polystyrene- block-polybutadienyl anion precursors with a multivalent linking agent. Therefore, it is a mixture of a number of branched block copolymers different in molecular weight, composition, and chain architecture. While individual LC analysis, including size exclusion chromatography, interaction chromatography, or liquid chromatography at critical condition, is not good enough to resolve all the polymer species, 2D-LC separations coupling two chromatography methods were able to resolve all polymer species present in the sample; at least 13 block copolymer species and a homopolystyrene blended. Four different 2D-LC analyses combining a different pair of two LC methods provide their characteristic separation results. The separation characteristics of the 2D-LC separations are compared to elucidate the elution characteristics of the block copolymer species.
USDA-ARS?s Scientific Manuscript database
In this study, optimization, extension, and validation of a streamlined, qualitative and quantitative multiclass, multiresidue method was conducted to monitor great than100 veterinary drug residues in meat using ultrahigh-performance liquid chromatography – tandem mass spectrometry (UHPLC-MS/MS). I...
USDA-ARS?s Scientific Manuscript database
We developed a rapid method with ultra-performance liquid chromatography – tandem mass spectrometry (UPLC-MS/MS) for the qualitative and quantitative analysis of plant proanthocyanidins (PAs) directly from crude plant extracts. The method utilizes a range of cone voltages to achieve the depolymeriza...
NASA Technical Reports Server (NTRS)
Fahey, Robert C.; Newton, Gerald L.
1988-01-01
Methods are described for the preparation and high-performance liquid chromatography (HPLC) analysis of monobromobimane derivatives of low molecular weight thiols in extracts of biological samples. Typical problems encountered in the development and application of these methods are discussed. Analysis of mung bean extract is used as an example.
NASA Technical Reports Server (NTRS)
Worstell, J. H.; Daniel, S. R.
1981-01-01
A method for the separation and analysis of tetralin hydroperoxide and its decomposition products by high pressure liquid chromatography has been developed. Elution with a single, mixed solvent from a micron-Porasil column was employed. Constant response factors (internal standard method) over large concentration ranges and reproducible retention parameters are reported.
A method for the detection of trace levels of N,N-diethyl-m-toluamide (DEET) in water is discussed. The method utilizes an on-line preconcentration column in series with high performance liquid chromatography (HPLC) and UV photodiode array detection. DEET, a common insect repel...
2007-06-01
T ACanadaY Approved for PublicR Distribution Uln& Liquid Chromatography Electrospray Ionization Mass Spectrometric ( LC -ESI- MS) and Desorption...consumer products with chemical warfare agents or other toxic chemicals. Liquid chromatography electrospray ionization mass spectrometry ( LC -ESI-MS) and...house LC -ESI-MS and LC -ESI-MS/MS methods were evaluated for the determination of chemical warfare agents in spiked bottled water samples. The
Code of Federal Regulations, 2014 CFR
2014-07-01
... Spectrometry (GC/MS) 525.3 24 Carbofuran High-performance liquid chromatography (HPLC) with post-column... (HPLC) with Post-Column Derivatization and Fluorescence Detection 6651 B 6651 B 6651 B-00, B-05... Chromatography/Mass Spectrometry (GC/MS) 525.3 24 Oxamyl High-performance liquid chromatography (HPLC) with post...
Jiménez, M; Mateo, R
1997-08-22
A method of analysis for trichothecenes (nivalenol, deoxynivalenol, 3- and 15-acetyldeoxynivalenol, diacetoxyscirpenol, neosolaniol, T-2 tetraol, T-2 and HT-2 toxins), zearalenone and zearalenols, and another method for determination of fumonisin B1 are described and applied to cultures of Fusarium isolated from bananas. Both methods were adapted from different techniques of extraction, clean-up and determination of these mycotoxins. The first method involves extraction with methanol-1% aqueous sodium chloride, clean-up of extracts by partition with hexane and dichloromethane, additional solid reversed-phase clean-up and analysis of two eluates by both high-performance liquid chromatography with ultraviolet detection and capillary gas chromatography. The method for fumonisin B1 implies extraction with aqueous methanol, concentration, clean-up with water and methanol on Amberlite XAD-2 column, formation of a fluorescent 4-fluoro-7-nitrobenzofurazan derivative and analysis by high-performance liquid chromatography with fluorescence detection. Both procedures give good limits of detection and recoveries, and are considered suitable for the detection and quantification of the studied toxins in corn and rice cultures of Fusarium spp. isolated from banana fruits.
Jiao, Lijin; Tao, Yanduo; Wang, Weidong; Shao, Yun; Mei, Lijuan; Wang, Qilan; Dang, Jun
2017-10-01
An offline preparative two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography coupled with hydrophilic interaction solid-phase extraction method was developed for the preparative isolation of flavonoid glycosides from a crude sample of Sphaerophysa salsula. First, the non-flavonoids were removed using an XAmide solid-phase extraction cartridge. Based on the separation results of three different chromatographic stationary phases, the first-dimensional preparation was performed on an XAqua C18 prep column, and 15 fractions were obtained from the 5.2 g target sample. Then, three representative fractions were selected for additional purification on an XAmide preparative column to further isolate the flavonoid glycosides. In all, eight flavonoid glycosides were isolated in purities over 97%. The results demonstrated that the two-dimensional liquid chromatography method used in this study was effective for the preparative separation of flavonoid glycosides from Sphaerophysa salsula. Additionally, this method showed great potential for the separation of flavonoid glycosides from other plant materials. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hwang, Taeik; Noh, Eunyoung; Jeong, Ji Hye; Park, Sung-Kwan; Shin, Dongwoo; Kang, Hoil
2018-02-28
A sensitive and specific high-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QTOF-MS) method combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of grayanotoxins I and III in dietary supplements and homemade wine. Grayanotoxins I and III were successfully extracted using solid-phase extraction cartridges, characterized by LC-QTOF-MS, and quantitated by LC-MS/MS. The LC-MS/MS calibration curves were linear over concentrations of 10-100 ng/mL (grayanotoxin I) and 20-400 ng/mL (grayanotoxin III). Grayanotoxins I and III were found in 51 foodstuffs, with quantitative determinations revealing total toxin concentrations of 18.4-101 000 ng/mL (grayanotoxin I) and 15.3-56 000 ng/mL (grayanotoxin III). The potential of the validated method was demonstrated by successful quantitative analysis of grayanotoxins I and III in dietary supplements and homemade wine; the method appears suitable for the routine detection of grayanotoxins I and III from Rhododendron brachycarpum.
Determination of Caffeine in Beverages by High Performance Liquid Chromatography.
ERIC Educational Resources Information Center
DiNunzio, James E.
1985-01-01
Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)
Yasukawa, Keiko; Shimosawa, Tatsuo; Okubo, Shigeo; Yatomi, Yutaka
2018-01-01
Background Human mercaptalbumin and human non-mercaptalbumin have been reported as markers for various pathological conditions, such as kidney and liver diseases. These markers play important roles in redox regulations throughout the body. Despite the recognition of these markers in various pathophysiologic conditions, the measurements of human mercaptalbumin and non-mercaptalbumin have not been popular because of the technical complexity and long measurement time of conventional methods. Methods Based on previous reports, we explored the optimal analytical conditions for a high-performance liquid chromatography method using an anion-exchange column packed with a hydrophilic polyvinyl alcohol gel. The method was then validated using performance tests as well as measurements of various patients' serum samples. Results We successfully established a reliable high-performance liquid chromatography method with an analytical time of only 12 min per test. The repeatability (within-day variability) and reproducibility (day-to-day variability) were 0.30% and 0.27% (CV), respectively. A very good correlation was obtained with the results of the conventional method. Conclusions A practical method for the clinical measurement of human mercaptalbumin and non-mercaptalbumin was established. This high-performance liquid chromatography method is expected to be a powerful tool enabling the expansion of clinical usefulness and ensuring the elucidation of the roles of albumin in redox reactions throughout the human body.
Akimoto, Masaru; Hokazono, Eisaku; Ota, Eri; Tateishi, Takiko; Kayamori, Yuzo
2016-01-01
Tamm-Horsfall protein (also known as uromodulin) is the most abundant urinary protein in healthy individuals. Since initially characterized by Tamm and Horsfall, the amount of urinary excretion and structural mutations of Tamm-Horsfall protein is associated with kidney diseases. However, currently available assays for Tamm-Horsfall protein, which are mainly enzyme-linked immunosorbent assay-based, suffer from poor reproducibility and might give false negative results. We developed a novel, quantitative assay for Tamm-Horsfall protein using reversed-phase high-performance liquid chromatography. A precipitation pretreatment avoided urine matrix interference and excessive sample dilution. High-performance liquid chromatography optimization based on polarity allowed excellent separation of Tamm-Horsfall protein from other major urine components. Our method exhibited high precision (based on the relative standard deviations of intraday [≤2.77%] and interday [≤5.35%] repetitions). The Tamm-Horsfall protein recovery rate was 100.0-104.2%. The mean Tamm-Horsfall protein concentration in 25 healthy individuals was 31.6 ± 18.8 mg/g creatinine. There was a strong correlation between data obtained by high-performance liquid chromatography and enzyme-linked immunosorbent assay (r = 0.906), but enzyme-linked immunosorbent assay values tended to be lower than high-performance liquid chromatography values at low Tamm-Horsfall protein concentrations. The high sensitivity and reproducibility of our Tamm-Horsfall protein assay will reduce the number of false negative results of the sample compared with enzyme-linked immunosorbent assay. Moreover, our method is superior to other high-performance liquid chromatography methods, and a simple protocol will facilitate further research on the physiological role of Tamm-Horsfall protein. © The Author(s) 2015.
Yilmaz, Bilal; Asci, Ali; Kucukoglu, Kaan; Albayrak, Mevlut
2016-08-01
A simple high-performance liquid chromatography method has been developed for the determination of formaldehyde in human tissue. FA Formaldehyde was derivatized with 2,4-dinitrophenylhydrazine. It was extracted from human tissue with ethyl acetate by liquid-liquid extraction and analyzed by high-performance liquid chromatography. The calibration curve was linear in the concentration range of 5.0-200 μg/mL. Intra- and interday precision values for formaldehyde in tissue were <6.9%, and accuracy (relative error) was better than 6.5%. The extraction recoveries of formaldehyde from human tissue were between 88 and 98%. The limits of detection and quantification of formaldehyde were 1.5 and 5.0 μg/mL, respectively. Also, this assay was applied to liver samples taken from a biopsy material. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Johnston, Patrick A; Brown, Robert C
2014-08-13
A rapid method for the quantitation of total sugars in pyrolysis liquids using high-performance liquid chromatography (HPLC) was developed. The method avoids the tedious and time-consuming sample preparation required by current analytical methods. It is possible to directly analyze hydrolyzed pyrolysis liquids, bypassing the neutralization step usually required in determination of total sugars. A comparison with traditional methods was used to determine the validity of the results. The calibration curve coefficient of determination on all standard compounds was >0.999 using a refractive index detector. The relative standard deviation for the new method was 1.13%. The spiked sugar recoveries on the pyrolysis liquid samples were between 104 and 105%. The research demonstrates that it is possible to obtain excellent accuracy and efficiency using HPLC to quantitate glucose after acid hydrolysis of polymeric and oligomeric sugars found in fast pyrolysis bio-oils without neutralization.
Zhang, Yaohai; Zhang, Xuelian; Jiao, Bining
2014-09-15
Dispersive liquid-liquid microextraction (DLLME) sample preparation and the quick, easy, cheap, effective, rugged and safe (QuEChERS) method combined with DLLME were developed and compared for the analysis of ten pyrethroids in various fruit juices using gas chromatography-electron capture detection (GC-ECD). QuEChERS-DLLME method has found its widespread applications to all the fruit juices including those samples with more complex matrices (orange, lemon, kiwi and mango) while DLLME was confined to the fruit juices with simpler matrices (apple, pear, grape and peach). The two methods provided acceptable recoveries and repeatability. In addition, the applicabilities of two methods were demonstrated with the real samples and further confirmed by gas chromatography-mass spectrometry (GC-MS). Copyright © 2014. Published by Elsevier Ltd.
USDA-ARS?s Scientific Manuscript database
A liquid chromatography-mass spectrometry method was developed for the analysis of the indolizidine alkaloid swainsonine and its N-oxide. The method is based on a one step solvent partitioning extraction procedure followed by trimethylsilylation of the dried extract and subsequent detection and qua...
Patricia L. Faulkner; Michele M. Schoeneberger; Kim H. Ludovici
1993-01-01
Foliar tissue was collected from a field study designed to test impacts of atmospheric pollutants on loblolIy pine (Pinus taeda L.) seedlings. Standard enzymatic (ENZ) and high performance liquid chromatography (HPLC) methods were used to analyze the tissue for soluble sugars. A comparison of the methods revealed no significant diffennces in accuracy...
Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W
2016-01-01
Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.
Li, Fangbing; Wang, Hui; Xin, Huaxia; Cai, Jianfeng; Fu, Qing; Jin, Yu
2016-12-01
Purified standards of xylooligosaccharides (XOSs) (DP2-6) were first prepared from a mixture of XOSs using solid phase extraction (SPE), followed by semi-preparative liquid chromatography both under hydrophilic interaction liquid chromatography (HILIC) modes. Then, an accurate quantitative analysis method based on hydrophilic interaction liquid chromatography-evaporative light scattering detection (HILIC-ELSD) was developed and validated for simultaneous determination of xylose (X1), xylobiose (X2), xylotriose (X3), xylotetraose (X4), xylopentaose (X5), and xylohexaose (X6). This developed HILIC-ELSD method was applied to the comparison of different hydrolysis methods for xylans and assessment of XOSs contents from different agricultural wastes. The result indicated that enzymatic hydrolysis was preferable with fewer by-products and high XOSs yield. The XOSs yield (48.40%) from sugarcane bagasse xylan was the highest, showing conversions of 11.21g X2, 12.75g X3, 4.54g X4, 13.31g X5, and 6.78g X6 from 100g xylan. Copyright © 2016 Elsevier Ltd. All rights reserved.
Viidanoja, Jyrki
2017-01-13
A new liquid chromatography-electrospray ionization-tandem Mass Spectrometry (LC-ESI-MS/MS) method was developed for the determination of more than 20 C 1 -C 6 alkyl and alkanolamines in aqueous matrices. The method employs Hydrophilic Interaction Liquid Chromatography Multiple Reaction Monitoring (HILIC-MRM) with a ZIC-pHILIC column and four stable isotope labeled amines as internal standards for signal normalization and quantification of the amines. The method was validated using a refinery process water sample that was obtained from a cooling cycle of crude oil distillation. The averaged within run precision, between run precision and accuracy were generally within 2-10%, 1-9% and 80-120%, respectively, depending on the analyte and concentration level. Selected aqueous process samples were analyzed with the method. Copyright © 2016 Elsevier B.V. All rights reserved.
Mahu, Ştefania Corina; Hăncianu, Monica; Agoroaei, Luminiţa; Grigoriu, Ioana Cezara; Strugaru, Anca Monica; Butnaru, Elena
2015-01-01
Hypertension is one of the most common causes of death, a complex and incompletely controlled disease for millions of patients. Metoprolol, bisoprolol, nebivolol and atenolol are selective beta-blockers frequently used in the management of arterial hypertension, alone or in fixed combination with other substances. This study presents the most used analytical methods for simultaneous determination in biological fluids of fixed combinations containing selective beta-blockers. Articles in Pub-Med, Science Direct and Wiley Journals databases published between years 2004-2014 were reviewed. Methods such as liquid chromatography--mass spectrometry--mass spectrometry (LC-MS/MS), high performance liquid chromatography (HPLC) or high performance liquid chromatography--mass spectrometry (HPLC-MS) were used for determination of fixed combination with beta-blockers in human plasma, rat plasma and human breast milk. LC-MS/MS method was used for simultaneous determination of fixed combinations of metoprolol with simvastatin, hydrochlorothiazide or ramipril, combinations of nebivolol and valsartan, or atenolol and amlodipine. Biological samples were processed by protein precipitation techniques or by liquid-liquid extraction. For the determination of fixed dose combinations of felodipine and metoprolol in rat plasma liquid chromatography--electrospray ionization--mass spectrometry (LC-ESI-MS/MS) was applied, using phenacetin as internal standard. HPLC-MS method was applied for the determination of bisoprolol and hydrochlorothiazide in human plasma. For the determination of atenolol and chlorthalidone from human breast milk and human plasma the HPLC method was used. The analytical methods were validated according to the specialized guidelines, and were applied to biological samples, thing that confirms the permanent concern of researchers in this field.
Jamalian, Azadeh; Sneekes, Evert-Jan; Wienk, Hans; Dekker, Lennard J. M.; Ruttink, Paul J. A.; Ursem, Mario; Luider, Theo M.; Burgers, Peter C.
2014-01-01
Here we describe a new method to identify calcium-binding sites in proteins using high-resolution liquid chromatography-mass spectrometry in concert with calcium-directed collision-induced dissociations. Our method does not require any modifications to the liquid chromatography-mass spectrometry apparatus, uses standard digestion protocols, and can be applied to existing high-resolution MS data files. In contrast to NMR, our method is applicable to very small amounts of complex protein mixtures (femtomole level). Calcium-bound peptides can be identified using three criteria: (1) the calculated exact mass of the calcium containing peptide; (2) specific dissociations of the calcium-containing peptide from threonine and serine residues; and (3) the very similar retention times of the calcium-containing peptide and the free peptide. PMID:25023127
Meng, Xiangpeng; Tong, Tong; Wang, Lianrong; Liu, Hanxia; Chan, Wan
2016-05-01
2-Alkylcyclobutanones (2-ACBs) are uniquely formed when triglycerides-containing food products are exposed to ionizing radiation. Thus, 2-ACBs have been used as marker molecules to identify irradiated food. Most methods to determine 2-ACBs involve mass spectrometric detection after chromatographic separation. The spectrofluorometer is rarely used to determine 2-ACBs because these molecules do not fluoresce. In this study, we developed an ultra-performance liquid chromatography (UPLC) method to determine 2-ACBs. 2-ACBs were converted into fluorophores after reacting with 1-naphthalenyl hydrazine to facilitate their sensitive and selective detection using a fluorescence detector (FLD). Analysis of 2-ACBs using our developed UPLC-FLD method allows sensitive determination of 2-ACBs at a detection limit of 2 ng 2-ACBs per g of fat (30 pg/injection), which is significantly lower than that of existing analytical methods. After validation for trueness and precision, the method was applied to γ-irradiated chicken samples to determine their 2-ACB content. Comparative studies employing liquid chromatography-tandem mass spectrometric method revealed no systematic difference between the two methods, thereby demonstrating that the proposed UPLC-FLD method can be suitably used to determine 2-ACBs in irradiated foodstuffs. Graphical Abstract Determination of radiation-induced food-borne 2-dodecylcyclobutanone and 2-tetradecylcyclobutanone by combining 1-naphthalenyl hydrazine derivatization and ultra-performance liquid chromatography with fluorescence detection.
Li, Yong; Pang, Tao; Shi, Junli; Lu, Xiuping; Deng, Jianhua; Lin, Qian
2014-11-01
Plant flavonoids are very important secondary metabolites for insect and virus control of their host plant and are potent nutrients for humans. To be able to understand the bioavailability and functions of plant flavonoids, it is necessary to reveal their exact chemical structures. Liquid chromatography with tandem mass spectrometry is a powerful approach for structural elucidation of metabolites. In this report, a two-step precursor ion scanning based liquid chromatography with tandem mass spectrometry method was developed for the structural elucidation of plant flavonoids. The established method consists of the two-step precursor ions scanning for possible flavonoids extraction, MS(2) fragment spectra acquisition and comparison with an online database, liquid chromatography retention rules correction, and commercial standards verification. The developed method was used for the structure elucidation of flavonoids in flowers and leaves of tobacco (Nicotiana tabacum), and 17 flavonoids were identified in the tobacco variety Yunyan 97. Nine of the 17 identified flavonoids were considered to be found in tobacco flowers or/and leaves for the first time based on the available references. This method was proved to be very effective and can be used for the identification of flavonoids in other plants. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel
2017-01-01
Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
This method provides a procedure for determination of chlorophylls a (chl a) and b (chl b) found in marine and freshwater phytoplankton. Reversed phase high performance liquid chromatography (HPLC) with detection at 440 nm is used to separate the pigments from a complex pigment ...
NASA Astrophysics Data System (ADS)
Tsyurupa, M. P.; Blinnikova, Z. K.; Il'in, M. M.; Davankov, V. A.; Parenago, O. O.; Pokrovskii, O. I.; Usovich, O. I.
2015-11-01
Monodisperse styrene-divinylbenzene (1 wt %) copolymer microbeads are obtained via the elaborate method of high-productivity precipitation polymerization. The crosslinking of this copolymer with chloromethyl methyl ether in the presence of Friedel-Crafts catalyst yields porous hypercrosslinked polymers with degrees of crosslinking that range from 200 to 500%. Microbead sorbents are shown to be suited for selective stationary phases for high-performance liquid chromatography and supercritical fluid chromatography.
High-pressure liquid chromatography analysis of antibiotic susceptibility disks.
Hagel, R B; Waysek, E H; Cort, W M
1979-01-01
The analysis of antibiotic susceptibility disks by high-pressure liquid chromatography (HPLC) was investigated. Methods are presented for the potency determination of mecillinam, ampicillin, carbenicillin, and cephalothin alone and in various combinations. Good agreement between HPLC and microbiological data is observed for potency determinations with recoveries of greater than 95%. Relative standard deviations of lower than 2% are recorded for each HPLC method. HPLC methods offer improved accuracy and greater precision when compared to the standard microbiological methods of analysis for susceptibility disks. PMID:507793
Bassanese, Danielle N; Conlan, Xavier A; Barnett, Neil W; Stevenson, Paul G
2015-05-01
This paper explores the analytical figures of merit of two-dimensional high-performance liquid chromatography for the separation of antioxidant standards. The cumulative two-dimensional high-performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods--the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high-performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10(-6) M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Phillips, Melissa M.; Bedner, Mary; Gradl, Manuela; Burdette, Carolyn Q.; Nelson, Michael A.; Yen, James H.; Sander, Lane C.; Rimmer, Catherine A.
2017-01-01
Two independent analytical approaches, based on liquid chromatography with absorbance detection and liquid chromatography with mass spectrometric detection, have been developed for determination of isoflavones in soy materials. These two methods yield comparable results for a variety of soy-based foods and dietary supplements. Four Standard Reference Materials (SRMs) have been produced by the National Institute of Standards and Technology to assist the food and dietary supplement community in method validation and have been assigned values for isoflavone content using both methods. These SRMs include SRM 3234 Soy Flour, SRM 3236 Soy Protein Isolate, SRM 3237 Soy Protein Concentrate, and SRM 3238 Soy-Containing Solid Oral Dosage Form. A fifth material, SRM 3235 Soy Milk, was evaluated using the methods and found to be inhomogeneous for isoflavones and unsuitable for value assignment. PMID:27832301
A simple method for the quantitative determination of elemental sulfur on oxidized sulfide minerals is described. Extraction of elemental sulfur in perchloroethylene and subsequent analysis with high-performance liquid chromatography were used to ascertain the total elemental ...
USDA-ARS?s Scientific Manuscript database
This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...
High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory
ERIC Educational Resources Information Center
Frey, Douglas D.; Guo, Hui; Karnik, Nikhila
2013-01-01
This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…
Method MS014 describes procedures for solvent extraction of aldicarb, bromadiolone, carbofuran, oxamyl and methomyl from water samples, followed by analysis using liquid chromatography tandem mass spectrometry (LC-MS-MS).
Caes, Benjamin R.; Van Oosbree, Thomas R.; Lu, Fachuang; Ralph, John; Maravelias, Christos T.
2015-01-01
Simulated moving bed chromatography, a continuous separation method, enables the nearly quantitative recovery of sugar products and ionic liquid solvent from chemical hydrolysates of biomass. The ensuing sugars support microbial growth, and the residual lignin from the process is intact. PMID:23939991
An, Meichen; Liu, Ning
2010-02-01
A high performance liquid chromatography-matrix-assisted laser desorption/ionization time of flight/time of flight mass spectrometry (HPLC-MALDI-TOF/TOF MS) method was developed for the separation and identification of bovine lactoferricin (LfcinB). Bovine lactoferrin was hydrolyzed by pepsin and then separated by ion exchange chromatography and reversed-phase liquid chromatography (RP-LC). The antibacterial activities of the fractions from RP-LC separation were determined and the protein concentration of the fraction with the highest activity was measured, whose sequence was indentified by MALDI-TOF/TOF MS. The relative molecular mass of LfcinB was 3 124.89 and the protein concentration was 18.20 microg/mL. The method of producing LfcinB proposed in this study has fast speed, high accuracy and high resolution.
Kaale, Eliangiringa; Van Schepdael, Ann; Roets, Eugène; Hoogmartens, Jos
2002-11-07
A reversed-phase liquid chromatography (LC) method has been developed, optimised and validated for the separation and quantitation of capsaicin (CP) and dihydrocapsaicin (DHCP) in a topical cream formulation. Sample preparation involves liquid-liquid extraction prior to LC analysis. The method uses a Hypersil C(18) BDS, 5 micrometer, 250x4.6 mm I.D. column maintained at 35 degrees C. The mobile phase comprises methanol, water, acetonitrile (ACN) and acetic acid (47:42:10:1, v/v/v/v) at a flow rate of 1.0 ml/min. Robustness was evaluated by performing a central composite face-centred design (CCF) experiment. The method shows good selectivity, linearity, sensitivity and repeatability. The conditions allow the separation and quantitation of CP and DHCP without interference from the other substances contained in the cream.
Otabe, Shuichi; Nakayama, Hitomi; Ohki, Tsuyoshi; Soejima, Eri; Tajiri, Yuji; Yamada, Kentaro
2017-07-01
Background We aimed to determine whether the discrepancy between haemoglobin A1c values determined by high-performance liquid chromatography and enzymatic haemoglobin A1c measurements in diabetic patients was clinically relevant. Methods We randomly recruited 1421 outpatients undergoing diabetic treatment and follow-up who underwent at least three haemoglobin A1c measurements between April 2014 and March 2015 at our clinic. In 6369 samples, haemoglobin A1c was simultaneously measured by HA-8160 and MetaboLead (enzymatic assay), and the values were compared. Results haemoglobin A1c measurements by high-performance liquid chromatography and enzymatic assay were strongly correlated (correlation coefficient: 0.9828, linear approximation curve y = 0.9986x - 0.2507). Mean haemoglobin A1c (6.8 ± 1.0%) measured by high-performance liquid chromatography was significantly higher than that measured by enzymatic assay (6.5 ± 1.0%, P < 0.0001). During the sample processing, four (0.3%) subjects presented consistently lower haemoglobin A1c values (<0.7%) by high-performance liquid chromatography than those from enzymatic assay. Of these, three had Hb Toranomon [β112 (G14) Cys→Trp]. The fourth had Hb Ube-2 [α68 (E17) Asn→Asp]. One other subject presented consistently higher haemoglobin A1c values (>1%) by high-performance liquid chromatography than those from enzymatic assay and was diagnosed with a -77 (T > C) mutation in the δ-globin gene. These unrelated asymptomatic subjects had normal erythrocyte profiles, without anaemia. Conclusions We showed that haemoglobin A1c values measured by high-performance liquid chromatography were significantly higher than those measured by enzymatic assay in diabetic subjects. However, when an oversized deviation (>0.7%) between glycaemic control status and haemoglobin A1c is apparent, clinicians should check the methods used to measure haemoglobin A1c and consider the possible presence of a haemoglobin variant.
Zimmerman, L.R.; Hostetler, K.A.; Thurman, E.M.
2000-01-01
Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: acetochlor ethanesulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The mean HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.50, and 2.0 mg/L (micrograms per liter) ranged from 84 to 112 percent, with relative standard deviations of 18 percent or less. The mean HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.20, and 2.0 mg/L ranged from 81 to 125 percent, with relative standard deviations of 20 percent or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 mg/L, whereas the LOQ using the HPLC/MS method was 0.05 mg/L. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water.
Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke
2006-11-03
A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.
Jin, Hongli; Liu, Yanfang; Guo, Zhimou; Wang, Jixia; Zhang, Xiuli; Wang, Chaoran; Liang, Xinmiao
2016-10-25
Traditional Chinese Medicine (TCM) is an ancient medical practice which has been used to prevent and cure diseases for thousands of years. TCMs are frequently multi-component systems with mainly unidentified constituents. The study of the chemical compositions of TCMs remains a hotspot of research. Different strategies have been developed to manage the significant complexity of TCMs, in an attempt to determine their constituents. Reversed-phase liquid chromatography (RPLC) is still the method of choice for the separation of TCMs, but has many problems related to limited selectivity. Recently, enormous efforts have been concentrated on the development of efficient liquid chromatography (LC) methods for TCMs, based on selective stationary phases. This can improve the resolution and peak capacity considerably. In addition, high-efficiency stationary phases have been applied in the analysis of TCMs since the invention of ultra high-performance liquid chromatography (UHPLC). This review describes the advances in LC methods in TCM research from 2010 to date, and focuses on novel stationary phases. Their potential in the separation of TCMs using relevant applications is also demonstrated. Copyright © 2016 Elsevier B.V. All rights reserved.
Turak, Fatma; Güzel, Remziye; Dinç, Erdal
2017-04-01
A new reversed-phase ultraperformance liquid chromatography method with a photodiode array detector was developed for the quantification of ascorbic acid (AA) and caffeine (CAF) in 11 different commercial drinks consisting of one energy drink and 10 ice tea drinks. Separation of the analyzed AA and CAF with an internal standard, caffeic acid, was performed on a Waters BEH C 18 column (100 mm × 2.1 mm, 1.7 μm i.d.), using a mobile phase consisting of acetonitrile and 0.2M H 3 PO 4 (11:89, v/v) with a flow rate of 0.25 mL/min and an injection volume of 1.0 μL. Calibration graphs for AA and CAF were computed from the peak area ratio of AA/internal standard and CAF/internal standard detected at 244.0 nm and 273.6 nm, respectively. The developed reversed-phase ultraperformance liquid chromatography method was validated by analyzing standard addition samples. The proposed reversed-phase ultraperformance liquid chromatography method gave us successful results for the quantitative analysis of commercial drinks containing AA and CAF substances. Copyright © 2016. Published by Elsevier B.V.
By-products of electrochemical synthesis of suberic acid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shirobokova, O.I.; Adamov, A.A.; Freidlin, G.N.
By-products of the electrochemical synthesis of dimethyl suberate from glutaric anhydride were studied. This is isolated by thermal dehydration of a mixture of lower dicarboxylic acids that are wastes from the production of adipic acid. To isolate the by-products, they used the methods of vacuum rectification and preparative gas-liquid chromatography, and for their identification, PMR, IR spectroscopy, gas-liquid chromatography, and other known physicochemical methods of investigation.
Varelis, P; Jeskelis, R
2008-10-01
For the determination of melamine and cyanuric acid the labelled internal standards [(13)C(3)]-melamine and [(13)C(3)]-cyanuric acid were synthesized using the common substrate [(13)C(3)]-cyanuric chloride by reaction with ammonia and acidified water, respectively. Standards with excellent isotopic and chemical purities were obtained in acceptable yields. These compounds were used to develop an isotope dilution liquid chromatography/mass spectrometry (LC/MS) method to determine melamine and cyanuric acid in catfish, pork, chicken, and pet food. The method involved extraction into aqueous methanol, liquid-liquid extraction and ion exchange solid phase clean-up, with normal phase high-performance liquid chromatography (HPLC) in the so-called hydrophilic interaction mode. The method had a limit of detection (LOD) of 10 microg kg(-1) for both melamine and cyanuric acid in the four foods with a percentage coefficient of variation (CV) of less than 10%. The recovery of the method at this level was in the range of 87-110% and 96-110% for melamine and cyanuric acid, respectively.
Liquid Crystals in Chromatography
NASA Astrophysics Data System (ADS)
Witkiewicz, Zygfryd
The following sections are included: * INTRODUCTION * LIQUID CRYSTALS SUITABLE FOR GAS CHROMATOGRAPHY * Monomeric Liquid Crystal Stationary Phases * Polymeric Liquid Crystal Stationary Phases * Polymeric Liquid Crystal Stationary Phases * Conventional Analytical Columns * Capillary Columns * FACTORS AFFECTING THE CHROMATOGRAPHIC SEPARATIONS ON LIQUID CRYSTAL STATIONARY PHASES * Kind of Mesophase of the Liquid Crystal * Molecular Structure of the Liquid Crystals and of the Chromatographed Substances * Substrate on which the Liquid Crystal is Deposited * ANALYTICAL APPLICATIONS OF LIQUID CRYSTAL STATIONARY PHASES IN GAS CHROMATOGRAPHY * Separation of Isomers of Benzene and Naphthalene Derivatives * Separation of Alkane and Alkene Isomers * Separation of Mixtures of Benzene and Aliphatic Hydrocarbon Derivatives Containing Heteroatoms * Separation of Polynuclear Hydrocarbons * INVESTIGATION OF THE PROPERTIES OF LIQUID CRYSTALS BY GAS CHROMATOGRAPHY * APPLICATION OF LIQUID CRYSTALS IN LIQUID CHROMATOGRAPHY * Column Chromatography * Thin-Layer Chromatography * APPLICATION OF LIQUID CRYSTAL STATIONARY PHASES IN SUPERCRITICAL FLUID CHROMATOGRAPHY * FINAL REMARKS * References
Kubica, Paweł; Wasik, Andrzej; Kot-Wasik, Agata; Namieśnik, Jacek
2014-05-01
The influence of sucrose combustion products on smoking and nicotine addiction is still controversial because the presence of the sucrose may be treated as a source of aldehydes and organic acids. In e-liquids used as refills for electronic cigarettes, which are made primarily of poly(propylene glycol), glycerine and ethanol, sucrose may be present at trace levels, and its impact on mainstream smoke formation, and hence on human health and smoking/nicotine addiction is unknown. An analytical method was developed where high-performance liquid chromatography in hydrophilic interaction liquid chromatography mode and tandem mass spectrometry were used for fast and simple determination of sucrose and other saccharides in e-liquids for electronic cigarettes. Minimal effort was required in the sample preparation step, and satisfactory results were obtained, and the sample matrix had an insignificant impact. The chromatographic separation was done using an Ascentis Express OH5 column (150 mm × 2.1 mm, 2.7 μm). The coefficients of variation for within-day precision for three concentrations were 2.4 %, 1.6 % and 2.3 %, and the between-day coefficients of variation for a single concentration were 2.1 %, 2.5 % and 1.7 % measured on the next 3 days. The detection limit was 0.73 μg/g, and the sucrose content in e-liquids ranged from 0.76 to 72.93 μg/g among 37 samples. Moreover, with the method presented it is possible to determine the presence of other saccharides such as fructose, glucose, maltose and lactose. However, only sucrose was found in all samples of e-liquids. The proposed method is rapid, simple and reliable in terms of high-performance liquid chromatography coupled with tandem mass spectrometry.
Onishi, S; Itoh, S; Ishida, Y
1982-01-01
An accurate and sensitive method that involves the group separations of serum bile acids (i.e. free and glycine- and taurine-conjugated bile acid fractions) by ion-exchange chromatography on piperidinohydroxypropyl-Sephadex LH-20 is described. Each group was then analysed by high-pressure liquid chromatography by using the post-column reaction technique with immobilized 3 alpha-hydroxy steroid dehydrogenase. The bile acid patterns in the umbilical venous serum samples were analysed by this method. Taurochenodeoxycholate predominated in the umbilical blood. PMID:6956336
Ceppa, F; Drouillard, I; Chianea, D; Burnat, P; Perrier, F; Vaillant, C; El Jahiri, Y
1999-01-01
Cardio-vascular diseases are the most common cause of death in industrialized countries. A new marker has emerged among offending risk factors in the past few years: homocysteine. This sulphured amino-acid is an important intermediate in transsulphuration and remethylation reactions of methionine's metabolism. We proposed to evaluate a home made method of determination for this parameter by high performance liquid chromatography (HPLC) and to compare it to fluorescence polarization immunoassay technique (FPIA) and to gaz phase chromatography (CG-SM). This method associated with good sensibility and precision remain much less expensive than FPIA technique.
das Neves Costa, Fernanda; Hubert, Jane; Borie, Nicolas; Kotland, Alexis; Hewitson, Peter; Ignatova, Svetlana; Renault, Jean-Hugues
2017-03-03
Countercurrent chromatography (CCC) and centrifugal partition chromatography (CPC) are support free liquid-liquid chromatography techniques sharing the same basic principles and features. Method transfer has previously been demonstrated for both techniques but never from one to another. This study aimed to show such a feasibility using fractionation of Schinus terebinthifolius berries dichloromethane extract as a case study. Heptane - ethyl acetate - methanol -water (6:1:6:1, v/v/v/v) was used as solvent system with masticadienonic and 3β-masticadienolic acids as target compounds. The optimized separation methodology previously described in Part I and II, was scaled up from an analytical hydrodynamic CCC column (17.4mL) to preparative hydrostatic CPC instruments (250mL and 303mL) as a part of method development. Flow-rate and sample loading were further optimized on CPC. Mobile phase linear velocity is suggested as a transfer invariant parameter if the CPC column contains sufficient number of partition cells. Copyright © 2017 Elsevier B.V. All rights reserved.
Lue, Bena-Marie; Guo, Zheng; Xu, Xuebing
2008-07-11
Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found essential for separation of flavonoids from strongly polar RTILs, whereby RTILs were generally visible as two major peaks identified based on an ion-pairing/exchanging hypothesis. C8 and C12 stationary phases were optimal while mobile phase pH (3-7) had only a minor influence on separation. The method developed was successfully applied for primary screening of RTILs (>20), with in depth evaluation of substrates in 10 RTILs, for their evaluation as reaction media.
Liquid Chromatography-Mass Spectrometry-based Quantitative Proteomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Fang; Liu, Tao; Qian, Weijun
2011-07-22
Liquid chromatography-mass spectrometry (LC-MS)-based quantitative proteomics has become increasingly applied for a broad range of biological applications due to growing capabilities for broad proteome coverage and good accuracy in quantification. Herein, we review the current LC-MS-based quantification methods with respect to their advantages and limitations, and highlight their potential applications.
Jia, Youmei; Cai, Jianfeng; Xin, Huaxia; Feng, Jiatao; Fu, Yanhui; Fu, Qing; Jin, Yu
2017-06-08
A preparative two dimensional hydrophilic interaction liquid chromatography/reversed-phase liquid chromatography (Pre-2D-HILIC/RPLC) method was established to separate and purify the components in Trachelospermum jasminoides . The pigments and strongly polar components were removed from the crude extract after the active carbon decolorization and solid phase extraction processes. A Click XIon column (250 mm×20 mm, 10 μm) was selected as stationary phase and water-acetonitrile as mobile phases in the first dimensional HILIC. Finally, 15 fractions were collected under UV-triggered mode. In the second dimensional RPLC, a C18 column (250 mm×20 mm, 5 μm) was selected and water-acetonitrile was used as mobile phases. As a result, 14 compounds with high purity were obtained, which were further identified by mass spectrometry (MS) and nuclear magnetic resonance (NMR). Finally, 11 lignan compounds and three flavonoid compounds were obtained. The method has a good orthogonality, and can improve the resolution and the peak capacity. It is significant for the separation of complex components from Trachelospermum jasminoides .
Liu, Lei; Cao, Na; Ma, Xingling; Xiong, Kaihe; Sun, Lili; Zou, Qiaogen
2016-04-01
High-performance liquid chromatography analysis of vonoprazan fumarate, a novel proton pump inhibitor drug revealed six impurities. These were identified by liquid chromatography with mass spectrometry. Further, the structures of the impurities were confirmed by synthesis followed by characterization by mass spectrometry, NMR spectroscopy, and infrared spectroscopy. On the basis of these data and knowledge of the synthetic scheme of vonoprazan fumarate, the previously unknown impurity was identified as 1-[5-(2-fluorophenyl)-1-(pyridin-3-ylsulfonyl)-1H-pyrrol-3-yl]-N-methyldimethylamine, which is a new compound. The possible mechanisms by which these impurities were formed were also discussed. A high-performance liquid chromatography method was optimized in order to separate, selectively detect, and quantify all process-related impurities of vonoprazan fumarate. The presented method has been validated in terms of linearity, limits of detection, and quantification, and response factors and, therefore, is highly suitable for routine analysis of vonoprazan fumarate related substances as well as stability studies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Major and Modified Nucleosides, RNA, and DNA
NASA Astrophysics Data System (ADS)
Gehrke, Charles W.; Kuo, Kenneth C.
Most analytical chemists are well aware of the rapid rate of development of high-performance liquid chromatography (HPLC) over the past 5 years. A number of articles have been published in Analytical Chemistry on different topics in HPLC and many papers appear in the chromatographic journals. Some books also have been published covering this subject. HPLC has proved to be a very effective, broadly applicable chromatographic method for the separation and analysis of complex molecules in fields as diverse as biochemistry and environmental, pharmaceutical, medical, and polymer chemistry. HPLC is now having a major impact on the clinical and research aspects of medical biochemistry. Although the contributions of HPLC to other disciplines generally complements gas-liquid chromatography, this method is destined to play a much greater role in medical and biochemical research. This is because many of the biomolecules, owing to their molecular complexity and size, are thermally unstable or nonvolatile, preventing or complicating an analysis by GC. A major factor contributing to the powerful advances in biomedical liquid chromatography is the development of reversed-phase high-performance liquid chromatography (RP-HPLC) using n-alkyl and phenyl chemically bonded substrates.
Wang, Tong; Wu, Hai-Long; Xie, Li-Xia; Zhu, Li; Liu, Zhi; Sun, Xiao-Dong; Xiao, Rong; Yu, Ru-Qin
2017-04-01
In this work, a smart chemometrics-enhanced strategy, high-performance liquid chromatography, and diode array detection coupled with second-order calibration method based on alternating trilinear decomposition algorithm was proposed to simultaneously quantify 12 polyphenols in different kinds of apple peel and pulp samples. The proposed strategy proved to be a powerful tool to solve the problems of coelution, unknown interferences, and chromatographic shifts in the process of high-performance liquid chromatography analysis, making it possible for the determination of 12 polyphenols in complex apple matrices within 10 min under simple conditions of elution. The average recoveries with standard deviations, and figures of merit including sensitivity, selectivity, limit of detection, and limit of quantitation were calculated to validate the accuracy of the proposed method. Compared to the quantitative analysis results from the classic high-performance liquid chromatography method, the statistical and graphical analysis showed that our proposed strategy obtained more reliable results. All results indicated that our proposed method used in the quantitative analysis of apple polyphenols was an accurate, fast, universal, simple, and green one, and it was expected to be developed as an attractive alternative method for simultaneous determination of multitargeted analytes in complex matrices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hostetler, K.A.; Thurman, E.M.
2000-01-01
Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.
Yan, Jun; Shi, Songshan; Wang, Hongwei; Liu, Ruimin; Li, Ning; Chen, Yonglin; Wang, Shunchun
2016-01-20
A novel analytical method for neutral monosaccharide composition analysis of plant-derived oligo- and polysaccharides was developed using hydrophilic interaction liquid chromatography coupled to a charged aerosol detector. The effects of column type, additives, pH and column temperature on retention and separation were evaluated. Additionally, the method could distinguish potential impurities in samples, including chloride, sulfate and sodium, from sugars. The results of validation demonstrated that this method had good linearity (R(2) ≥ 0.9981), high precision (relative standard deviation ≤ 4.43%), and adequate accuracy (94.02-103.37% recovery) and sensitivity (detection limit: 15-40 ng). Finally, the monosaccharide compositions of the polysaccharide from Eclipta prostrasta L. and stachyose were successfully profiled through this method. This report represents the first time that all of these common monosaccharides could be well-separated and determined simultaneously by high performance liquid chromatography without additional derivatization. This newly developed method is convenient, efficient and reliable for monosaccharide analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.
Tomková, Jana; Ondra, Peter; Kocianová, Eva; Václavík, Jan
2017-07-01
This paper presents a method for the determination of acebutolol, betaxolol, bisoprolol, metoprolol, nebivolol and sotalol in human serum by liquid-liquid extraction and ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry. After liquid-liquid extraction, beta blockers were separated on a reverse-phase analytical column (Acclaim RS 120; 100 × 2.1 mm, 2.2 μm). The total run time was 6 min for each sample. Linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery and sample stability were evaluated. The method was successfully applied to the therapeutic drug monitoring of 108 patients with hypertension. This method was also used for determination of beta blockers in 33 intoxicated patients. Copyright © 2016 John Wiley & Sons, Ltd.
Direct probing of chromatography columns by laser-induced fluorescence
NASA Astrophysics Data System (ADS)
McGuffin, V. L.
1992-12-01
This report summarizes the progress and accomplishments of this research project from 1 Sep. 1989 to 28 Feb. 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe in supercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.
Haggarty, Jennifer; Burgess, Karl Ev
2017-02-01
The metabolome is the complete complement of metabolites (small organic biomolecules). In order to comprehensively understand the effect of stimuli on a biological system, it is important to detect as many of the metabolites within that system as possible. This review briefly describes some new advances in liquid and gas chromatography to improve coverage of the metabolome, including the serial combination of two columns in tandem, column switching and different variations of two-dimensional chromatography. Supercritical fluid chromatography could provide complimentary data to liquid and gas chromatography. Although there have been many recent advancements in the field of metabolomics, it is evident that a combination, rather than a single method, is required to approach full coverage of the metabolome. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Sheng, Qianying; Yang, Kaiya; Ke, Yanxiong; Liang, Xinmiao; Lan, Minbo
2016-09-01
Maltose covalently bonded to silica was prepared by using carbonyl diimidazole as a cross-linker and employed as a stationary phase for hydrophilic interaction liquid chromatography. The column efficiency and the effect of water content, buffer concentration, and pH value influenced on retention were investigated. The separation or enrichment selectivity was also studied with nucleosides, saccharides, amino acids, peptides, and glycopeptides. The results indicated that the stationary phase processed good separation efficiency and separation selectivity in hydrophilic interaction liquid chromatography mode. Moreover, a two-dimensional hydrophilic interaction liquid chromatography× reversed-phase liquid chromatography method with high orthogonality was developed to analyze the Ginkgo Biloba extract fractions. The development of this two-dimensional chromatographic system would be an effective tool for the separation of complex samples of different polarities and contents. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Development of Impurity Profiling Methods Using Modern Analytical Techniques.
Ramachandra, Bondigalla
2017-01-02
This review gives a brief introduction about the process- and product-related impurities and emphasizes on the development of novel analytical methods for their determination. It describes the application of modern analytical techniques, particularly the ultra-performance liquid chromatography (UPLC), liquid chromatography-mass spectrometry (LC-MS), high-resolution mass spectrometry (HRMS), gas chromatography-mass spectrometry (GC-MS) and high-performance thin layer chromatography (HPTLC). In addition to that, the application of nuclear magnetic resonance (NMR) spectroscopy was also discussed for the characterization of impurities and degradation products. The significance of the quality, efficacy and safety of drug substances/products, including the source of impurities, kinds of impurities, adverse effects by the presence of impurities, quality control of impurities, necessity for the development of impurity profiling methods, identification of impurities and regulatory aspects has been discussed. Other important aspects that have been discussed are forced degradation studies and the development of stability indicating assay methods.
Araujo, Pedro; Tilahun, Ephrem; Breivik, Joar Fjørtoft; Abdulkader, Bashir M; Frøyland, Livar; Zeng, Yingxu
2016-02-01
It is well-known that triacylglycerol (TAG) ions are suppressed by phospholipid (PL) ions in regiospecific analysis of TAG by mass spectrometry (MS). Hence, it is essential to remove the PL during sample preparation prior to MS analysis. The present article proposes a cost-effective liquid-liquid extraction (LLE) method to remove PL from TAG in different kinds of biological samples by using methanol, hexane and water. High performance thin layer chromatography confirmed the lack of PL in krill oil and salmon liver samples, submitted to the proposed LLE protocol, and liquid chromatography tandem MS confirmed that the identified TAG ions were highly enhanced after implementing the LLE procedure. Copyright © 2015 Elsevier B.V. All rights reserved.
Hu, J-Y; Deng, Z-B; Qin, D-M
2009-12-01
JS-118 is a diacylhydrazines-type insect growth regulator used extensively in China now. An analytical method for residues determination of JS-118 in cabbage and soil samples by high performance liquid chromatography with DAD detection was established and optimized. Primary secondary amine solid phase extraction cartridge was used for sample preparation. Mean recoveries for the analyte ranged from 96.6% to 107.0% with CV value less than 4.7%. The limit of quantification is 0.01 mg/kg. Direct confirmation of JS-118 residues in samples was realized by high performance liquid chromatography-mass spectrometry. The proposed method is simple, rapid and reliable to perform and could be utilized for monitoring of pesticides residues.
Verweij-van Wissen, C P W G M; Aarnoutse, R E; Burger, D M
2005-02-25
A reversed phase high performance liquid chromatography method was developed for the simultaneous quantitative determination of the nucleoside reverse transcriptase inhibitors (NRTIs) lamivudine, didanosine, stavudine, zidovudine and abacavir in plasma. The method involved solid-phase extraction with Oasis MAX cartridges from plasma, followed by high performance liquid chromatography with a SymmetryShield RP 18 column and ultraviolet detection set at a wavelength of 260 nm. The assay was validated over the concentration range of 0.015-5 mg/l for all five NRTIs. The average accuracies for the assay were 92-102%, inter- and intra-day coefficients of variation (CV) were <2.5% and extraction recoveries were higher than 97%. This method proved to be simple, accurate and precise, and is currently in use in our laboratory for the quantitative analysis of NRTIs in plasma.
Acrylamide: formation, occurrence in food products, detection methods, and legislation.
Arvanitoyannis, Ioannis S; Dionisopoulou, Niki
2014-01-01
This review aims at summarizing the most recent updates in the field of acrylamide (AA) formation (mechanism, conditions) and the determination of AA in a number of foods (fried or baked potatoes, chips, coffee, bread, etc). The methods applied for AA detection [Capillary Electrophoresis-Mass Spectrometry (CE-MS), Liquid Chromatography-Mass Spectrometry (LC-MS), Non-Aqueous Capillary Electrophoresis (NACE), High Performance Liquid Chromatography-Mass Spectrometry (HPLC-MS), Pressurized Fluid Extraction (PFE), Matrix Solid-Phase Dispersion (MSPD), Gas Chromatography-Mass Spectrometry (GC-MS), Solid-Phase MicroExtraction-Gas Chromatography (SPME-GC), Enzyme Linked Immunosorbent Assay (ELISA), and MicroEmulsion ElectroKinetic Chromatography (MEEKC) are presented and commented. Several informative figures and tables are included to show the effect of conditions (temperature, time) on the AA formation. A section is also included related to AA legislation in EU and US.
Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy
2016-06-17
This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents. Copyright © 2016 Elsevier B.V. All rights reserved.
Cunha, Rafael R; Chaves, Sandro C; Ribeiro, Michelle M A C; Torres, Lívia M F C; Muñoz, Rodrigo A A; Dos Santos, Wallans T P; Richter, Eduardo M
2015-05-01
Paracetamol, caffeine and ibuprofen are found in over-the-counter pharmaceutical formulations. In this work, we propose two new methods for simultaneous determination of paracetamol, caffeine and ibuprofen in pharmaceutical formulations. One method is based on high-performance liquid chromatography with diode-array detection and the other on capillary electrophoresis with capacitively coupled contactless conductivity detection. The separation by high-performance liquid chromatography with diode-array detection was achieved on a C18 column (250×4.6 mm(2), 5 μm) with a gradient mobile phase comprising 20-100% acetonitrile in 40 mmol L(-1) phosphate buffer pH 7.0. The separation by capillary electrophoresis with capacitively coupled contactless conductivity detection was achieved on a fused-silica capillary (40 cm length, 50 μm i.d.) using 10 mmol L(-1) 3,4-dimethoxycinnamate and 10 mmol L(-1) β-alanine with pH adjustment to 10.4 with lithium hydroxide as background electrolyte. The determination of all three pharmaceuticals was carried out in 9.6 min by liquid chromatography and in 2.2 min by capillary electrophoresis. Detection limits for caffeine, paracetamol and ibuprofen were 4.4, 0.7, and 3.4 μmol L(-1) by liquid chromatography and 39, 32, and 49 μmol L(-1) by capillary electrophoresis, respectively. Recovery values for spiked samples were between 92-107% for both proposed methods. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Recent applications of hydrophilic interaction liquid chromatography in pharmaceutical analysis.
Zhang, Qian; Yang, Feng-Qing; Ge, Liya; Hu, Yuan-Jia; Xia, Zhi-Ning
2017-01-01
Hydrophilic interaction liquid chromatography, an alternative liquid chromatography mode, is of particular interest in separating hydrophilic and polar ionic compounds. Compared with traditional liquid chromatography techniques, hydrophilic interaction liquid chromatography offers specific advantages mainly including: (1) relatively green and water-soluble mobile phase composition, which enhances the solubility of hydrophilic and polar ionic compounds; (2) no need for ion-pairing reagents and high content of organic solvent, which benefits mass spectrometry detection; (3) high orthogonality to reverse-phase liquid chromatography, well adapted to two-dimensional liquid chromatography for complicated samples. Therefore, hydrophilic interaction liquid chromatography has been rapidly developed in many areas over the past decades. This review summarizes the recent progress (from 2012 to July 2016) of hydrophilic interaction liquid chromatography in pharmaceutical analysis, with the focus on detecting chemical drugs in various matrices, charactering active compounds of natural products and assessing biotherapeutics through typical structure unit. Moreover, the retention mechanism and behavior of analytes in hydrophilic interaction liquid chromatography as well as some novel hydrophilic interaction liquid chromatography columns used for pharmaceutical analysis are also described. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhou, Xi; Cui, Kunyan; Zeng, Feng; Li, Shoucong; Zeng, Zunxiang
2016-06-01
In the present study, solid-phase extraction cartridges including silica reversed-phase Isolute C18, polymeric reversed-phase Oasis HLB and mixed-mode anion-exchange Oasis MAX, and liquid-liquid extractions with ethyl acetate, n-hexane, dichloromethane and its mixtures were compared for clean-up of phthalate monoesters from vegetable samples. Best recoveries and minimised matrix effects were achieved using ethyl acetate/n-hexane liquid-liquid extraction for these target compounds. A simple and selective method, based on sample preparation by ultrasonic extraction and liquid-liquid extraction clean-up, for the determination of phthalate monoesters in vegetable samples by liquid chromatography/electrospray ionisation-tandem mass spectrometry was developed. The method detection limits for phthalate monoesters ranged from 0.013 to 0.120 ng g(-1). Good linearity (r(2)>0.991) between MQLs and 1000× MQLs was achieved. The intra- and inter-day relative standard deviation values were less than 11.8%. The method was successfully used to determine phthalate monoester metabolites in the vegetable samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pierson, Stephen A; Trujillo-Rodríguez, María J; Anderson, Jared L
2018-05-29
An ionic-liquid-based in situ dispersive liquid-liquid microextraction method coupled to headspace gas chromatography and mass spectrometry was developed for the rapid analysis of ultraviolet filters. The chemical structures of five ionic liquids were specifically designed to incorporate various functional groups for the favorable extraction of the target analytes. Extraction parameters including ionic liquid mass, molar ratio of ionic liquid to metathesis reagent, vortex time, ionic strength, pH, and total sample volume were studied and optimized. The effect of the headspace temperature and volume during the headspace sampling step was also evaluated to increase the sensitivity of the method. The optimized procedure is fast as it only required ∼7-10 min per extraction and allowed for multiple extractions to be performed simultaneously. In addition, the method exhibited high precision, good linearity, and low limits of detection for six ultraviolet filters in aqueous samples. The developed method was applied to both pool and lake water samples attaining acceptable relative recovery values. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ouyang, Ying; Mansell, Robert S; Nkedi-Kizza, Peter
2004-01-01
A high performance liquid chromatography (HPLC) method with UV detection was developed to analyze paraquat (1,1'-dimethyl-4,4'-dipyridinium dichloride) herbicide content in soil solution samples. The analytical method was compared with the liquid scintillation counting (LSC) method using 14C-paraquat. Agreement obtained between the two methods was reasonable. However, the detection limit for paraquat analysis was 0.5 mg L(-1) by the HPLC method and 0.05 mg L(-1) by the LSC method. The LSC method was, therefore, 10 times more precise than the HPLC method for solution concentrations less than 1 mg L(-1). In spite of the high detection limit, the UC (nonradioactive) HPLC method provides an inexpensive and environmentally safe means for determining paraquat concentration in soil solution compared with the 14C-LSC method.
Li, Jia-Fu; Fang, Hua; Yan, Xia; Chang, Fang-Rong; Wu, Zhen; Wu, Yun-Long; Qiu, Ying-Kun
2016-07-22
An on-line comprehensive preparative two-dimensional normal-phase liquid chromatography×reversed-phase liquid chromatography (2D NPLC×RPLC) system was constructed with a newly developed vacuum evaporation assisted adsorption (VEAA) interface, allowing fast removal of NPLC solvent in the vacuum condition and successfully solving the solvent incompatibility problem between NPLC and RPLC. The system achieved on-line solvent exchange within the two dimensions and its performance was illustrated by gram-scale isolation of crude extract from the venom of Bufo bufo gargarizans. Within separation time of ∼20h, 19 compounds were obtained with high purity in a single run. With the VEAA interface, the 2D system exhibited apparent advantages in separation efficiency and automation compared with conventional methods, indicating its promising application in the routine separation process for complicated natural products. Copyright © 2016 Elsevier B.V. All rights reserved.
Miralles, Pablo; Vrouvaki, Ilianna; Chisvert, Alberto; Salvador, Amparo
2016-07-01
An analytical method for the simultaneous determination of phenethyl alcohol, methylpropanediol, phenylpropanol, caprylyl glycol, and ethylhexylglycerin, which are used as alternative preservatives in cosmetic products, has been developed. The method is based on liquid chromatography with UV spectrophotometric detection after chromophoric derivatization with benzoyl chloride and vortex-assisted liquid-liquid semimicroextraction. Different chromatographic parameters, derivatization conditions, and sample preparation variables were studied. Under optimized conditions, the limits of detection values for the analytes ranged from 0.02 to 0.06µgmL(-1). The method was validated with good recovery values (84-118%) and precision values (3.9-9.5%). It was successfully applied to 10 commercially available cosmetic samples. The good analytical features of the proposed method besides of its environmentally-friendly characteristics, make it useful to carry out the quality control of cosmetic products containing the target compounds as preservative agents. Copyright © 2016 Elsevier B.V. All rights reserved.
Schneider, M J; Donoghue, D J
2004-05-01
Regulatory monitoring for most antibiotic residues in edible poultry tissues is often accomplished with accurate, although expensive and technically demanding, chemical analytical techniques. The purpose of this study is to determine if a simple, inexpensive bioassay could detect fluoroquinolone (FQ) residues in chicken muscle above the FDA established tolerance (300 ppb) comparable to a liquid chromatography-fluorescencemass spectrometry(n) method. To produce incurred enrofloxacin (ENRO) tissues (where ENRO is incorporated into complex tissue matrices) for the method comparison, 40-d-old broilers (mixed sex) were orally dosed through drinking water for 3 d at the FDA-approved dose of ENRO (50 ppm). At the end of each day of the 3-d dosing period and for 3 d postdosing, birds were sacrificed and breast and thigh muscle collected and analyzed. Both methods were able to detect ENRO at and below the tolerance level in the muscle, with limits of detection of 26 ppb (bioassay), 0.1 ppb for ENRO, and 0.5 ppb for the ENRO metabolite, ciprofloxacin (liquid chromatography-fluorescence-mass spectrometry(n)). All samples that had violative levels of antibiotic were detected by the bioassay. These results support the use of this bioassay as a screening method for examining large numbers of samples for regulatory monitoring. Positive samples should then be examined by a more extensive method, such as liquid chromatography-fluorescence-mass spectrometry(n), to provide confirmation of the analyte.
Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal
2017-11-24
Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements. Copyright © 2017 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
A selective ultra-high performance liquid chromatography-didode array detector-quadrapole time of flight-mass spectrometry (UHPLC-DAD-QToF-MS) method has been developed to screen grapefruit seeds, and other citrus seed samples for limonoid aglycones, limonoid acids, limonoid glucosides and flavonoid...
USDA-ARS?s Scientific Manuscript database
An ultra-high performance liquid chromatography-ion mobility- quadrupole time-of-flight mass spectrometry (UHPLC-IM-QTOF-MS) method was developed for profiling the indole alkaloids in yohimbe bark. Many indole alkaloids with the yohimbine core structure, plus methylated, oxidized, and reduced speci...
Benzoin Condensation: Monitoring a Chemical Reaction by High-Pressure Liquid Chromatography
ERIC Educational Resources Information Center
Bhattacharya, Apurba; Purohit, Vikram C.; Bellar, Nicholas R.
2004-01-01
High-pressure liquid chromatography (HPLC) is the preferred method of separating a variety of materials in complex mixtures such as pharmaceuticals, polymers, soils, food products and biological fluids and is also considered to be a powerful analytical tool in both academia and industry. The use of HPLC analysis as a means of monitoring and…
ERIC Educational Resources Information Center
Leacock, Rachel E.; Stankus, John J.; Davis, Julian M.
2011-01-01
A high-performance liquid chromatography experiment to determine the concentration of caffeine and vitamin B6 in sports energy drinks has been developed. This laboratory activity, which is appropriate for an upper-level instrumental analysis course, illustrates the standard addition method and simultaneous determination of two species. (Contains 1…
ERIC Educational Resources Information Center
Penteado, Jose C.; Masini, Jorge Cesar
2011-01-01
Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…
Phillips, Melissa M; Bedner, Mary; Reitz, Manuela; Burdette, Carolyn Q; Nelson, Michael A; Yen, James H; Sander, Lane C; Rimmer, Catherine A
2017-02-01
Two independent analytical approaches, based on liquid chromatography with absorbance detection and liquid chromatography with mass spectrometric detection, have been developed for determination of isoflavones in soy materials. These two methods yield comparable results for a variety of soy-based foods and dietary supplements. Four Standard Reference Materials (SRMs) have been produced by the National Institute of Standards and Technology to assist the food and dietary supplement community in method validation and have been assigned values for isoflavone content using both methods. These SRMs include SRM 3234 Soy Flour, SRM 3236 Soy Protein Isolate, SRM 3237 Soy Protein Concentrate, and SRM 3238 Soy-Containing Solid Oral Dosage Form. A fifth material, SRM 3235 Soy Milk, was evaluated using the methods and found to be inhomogeneous for isoflavones and unsuitable for value assignment. Graphical Abstract Separation of six isoflavone aglycones and glycosides found in Standard Reference Material (SRM) 3236 Soy Protein Isolate.
High-performance liquid chromatography of oligoguanylates at high pH
NASA Technical Reports Server (NTRS)
Stribling, R.; Deamer, D. (Principal Investigator)
1991-01-01
Because of the stable self-structures formed by oligomers of guanosine, standard high-performance liquid chromatography techniques for oligonucleotide fractionation are not applicable. Previously, oligoguanylate separations have been carried out at pH 12 using RPC-5 as the packing material. While RPC-5 provides excellent separations, there are several limitations, including the lack of a commercially available source. This report describes a new anion-exchange high-performance liquid chromatography method using HEMA-IEC BIO Q, which successfully separates different forms of the guanosine monomer as well as longer oligoguanylates. The reproducibility and stability at high pH suggests a versatile role for this material.
Recent trends in the impurity profile of pharmaceuticals
Pilaniya, Kavita; Chandrawanshi, Harish K.; Pilaniya, Urmila; Manchandani, Pooja; Jain, Pratishtha; Singh, Nitin
2010-01-01
Various regulatory authorities such as the International Conference on Harmonization (ICH), the United States Food and Drug administration (FDA), and the Canadian Drug and Health Agency (CDHA) are emphasizing on the purity requirements and the identification of impurities in Active Pharmaceutical Ingredients (APIs). The various sources of impurity in pharmaceutical products are — reagents, heavy metals, ligands, catalysts, other materials like filter aids, charcoal, and the like, degraded end products obtained during \\ after manufacturing of bulk drugs from hydrolysis, photolytic cleavage, oxidative degradation, decarboxylation, enantiomeric impurity, and so on. The different pharmacopoeias such as the British Pharmacopoeia, United State Pharmacopoeia, and Indian Pharmacopoeia are slowly incorporating limits to allowable levels of impurities present in APIs or formulations. Various methods are used to isolate and characterize impurities in pharmaceuticals, such as, capillary electrophoresis, electron paramagnetic resonance, gas–liquid chromatography, gravimetric analysis, high performance liquid chromatography, solid-phase extraction methods, liquid–liquid extraction method, Ultraviolet Spectrometry, infrared spectroscopy, supercritical fluid extraction column chromatography, mass spectrometry, Nuclear magnetic resonance (NMR) spectroscopy, and RAMAN spectroscopy. Among all hyphenated techniques, the most exploited techniques for impurity profiling of drugs are Liquid Chromatography (LC)-Mass Spectroscopy (MS), LC-NMR, LC-NMR-MS, GC-MS, and LC-MS. This reveals the need and scope of impurity profiling of drugs in pharmaceutical research. PMID:22247862
Ma, Zhen; Ge, Liya; Lee, Anna S Y; Yong, Jean Wan Hong; Tan, Swee Ngin; Ong, Eng Shi
2008-03-10
Coconut (Cocos nucifera L.) water, which contains many uncharacterized phytohormones is extensively used as a growth promoting supplement in plant tissue culture. In this paper, a high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of various classes phytohormones, including indole-3-acetic acid (IAA), indole-3-butyric acid (IBA), abscisic acid (ABA), gibberellic acid (GA), zeatin (Z), N(6)-benzyladenine (BA), alpha-naphthaleneacetic acid (NAA) and 2,4-dichlorophenoxyacetic acid (2,4-D) in young coconut water (CW). The analysis was carried out using a reverse-phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid, pH adjusted to 3.2 with triethylamine (TEA)) modified by methanol, and solute detection made at 265 nm wavelength. The method was validated for specificity, quantification, accuracy and precision. After preconcentration of putative endogenous phytohormones in CW using C(18) solid-phase extraction (SPE) cartridges, the HPLC method was able to screen for putative endogenous phytohormones present in CW. Finally, the identities of the putative phytohormones present in CW were further confirmed using independent liquid chromatography-tandem mass spectrometry (LC-MS/MS) equipped with an electrospray ionization (ESI) interface.
Xu, Liyuan; Gao, Haoshi; Li, Liangxing; Li, Yinnong; Wang, Liuyun; Gao, Chongkai; Li, Ning
2016-12-23
The effective permeability coefficient is of theoretical and practical importance in evaluation of the bioavailability of drug candidates. However, most methods currently used to measure this coefficient are expensive and time-consuming. In this paper, we addressed these problems by proposing a new measurement method which is based on the microemulsion liquid chromatography. First, the parallel artificial membrane permeability assays model was used to determine the effective permeability of drug so that quantitative retention-activity relationships could be established, which were used to optimize the microemulsion liquid chromatography. The most effective microemulsion system used a mobile phase of 6.0% (w/w) Brij35, 6.6% (w/w) butanol, 0.8% (w/w) octanol, and 86.6% (w/w) phosphate buffer (pH 7.4). Next, support vector machine and back-propagation neural networks are employed to develop a quantitative retention-activity relationships model associated with the optimal microemulsion system, and used to improve the prediction ability. Finally, an adequate correlation between experimental value and predicted value is computed to verify the performance of the optimal model. The results indicate that the microemulsion liquid chromatography can serve as a possible alternative to the PAMPA method for determination of high-throughput permeability and simulation of biological processes. Copyright © 2016. Published by Elsevier B.V.
Li, Jun; Bi, Yanlan; Sun, Shangde; Peng, Dan
2017-11-01
A normal-phase high performance liquid chromatography method for the simultaneous determination of tert-butylhydroquinone, tert-butylquinone, butylated hydroxytoluene, 2-tert-butyl-4-hydroxyanisole, 3-tert-butyl-4-hydroxyanisole, α-tocopherol, γ-tocopherol, and δ-tocopherol in edible oils was investigated. A silica column was used to separate the analytes with the gradient elution. An ultraviolet-visible detector was set at dual wavelengths mode (280 and 310nm). The column temperature was 30°C. The analytes were directly extracted with methanol. Results showed that the normal-phase high performance liquid chromatography method performed well with wide liner ranges (0.10∼500.00μg/mL, R 2 >0.9998), low limits of detection and quantitation (below 0.40 and 1.21μg/mL, respectively), and good recoveries (81.38∼102.34% in soybean oils and 83.03∼100.79% in lard, respectively). The reduction of tert-butylquinone caused by the reverse-phase high performance liquid chromatography during the injection was avoided with the current normal-phase method. The two isomers of butylated hydroxyanisole can also be separated with good resolution. Copyright © 2017 Elsevier Ltd. All rights reserved.
Yang, Xiao; Diao, Chun-Peng; Sun, Ai-Ling; Liu, Ren-Min
2014-10-01
A method for the rapid pretreatment and determination of bisphenol A in water samples based on vortex-assisted liquid-liquid microextraction followed by high-performance liquid chromatography with fluorescence detection was proposed in this paper. A simple apparatus consisting of a test tube and a cut-glass dropper was designed and applied to collect the floating extraction drop in liquid-liquid microextraction when low-density organic solvent was used as the extraction solvent. Solidification and melting steps that were tedious but necessary once the low-density organic solvent used as extraction solvent could be avoided by using this apparatus. Bisphenol A was selected as model pollutant and vortex-assisted liquid-liquid microextraction was employed to investigate the usefulness of the apparatus. High-performance liquid chromatography with fluorescence detection was selected as the analytical tool for the detection of bisphenol A. The linear dynamic range was from 0.10 to 100 μg/L for bisphenol A, with good squared regression coefficient (r(2) = 0.9990). The relative standard deviation (n = 7) was 4.7% and the limit of detection was 0.02 μg/L. The proposed method had been applied to the determination of bisphenol A in natural water samples and was shown to be economical, fast, and convenient. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
De Vrieze, Mike; Lynen, Frédéric; Chen, Kai; Szucs, Roman; Sandra, Pat
2013-07-01
Several in vitro methods have been tested for their ability to predict drug penetration across the blood-brain barrier (BBB) into the central nervous system (CNS). In this article, the performance of a variety of micellar liquid chromatographic (MLC) methods and immobilized artificial membrane (IAM) liquid chromatographic approaches were compared for a set of 45 solutes. MLC measurements were performed on a C18 column with sodium dodecyl sulfate (SDS), polyoxyethylene (23) lauryl ether (Brij35), or sodium deoxycholate (SDC) as surfactant in the micellar mobile phase. IAM liquid chromatography measurements were performed with Dulbecco's phosphate-buffered saline (DPBS) and methanol as organic modifier in the mobile phase. The corresponding retention and computed descriptor data for each solute were used for construction of models to predict transport across the blood-brain barrier (log BB). All data were correlated with experimental log BB values and the relative performance of the models was studied. SDS-based models proved most suitable for prediction of log BB values, followed closely by a simplified IAM method, in which it could be observed that extrapolation of retention data to 0% modifier in the mobile phase was unnecessary.
Analytical methodologies for broad metabolite coverage of exhaled breath condensate.
Aksenov, Alexander A; Zamuruyev, Konstantin O; Pasamontes, Alberto; Brown, Joshua F; Schivo, Michael; Foutouhi, Soraya; Weimer, Bart C; Kenyon, Nicholas J; Davis, Cristina E
2017-09-01
Breath analysis has been gaining popularity as a non-invasive technique that is amenable to a broad range of medical uses. One of the persistent problems hampering the wide application of the breath analysis method is measurement variability of metabolite abundances stemming from differences in both sampling and analysis methodologies used in various studies. Mass spectrometry has been a method of choice for comprehensive metabolomic analysis. For the first time in the present study, we juxtapose the most commonly employed mass spectrometry-based analysis methodologies and directly compare the resultant coverages of detected compounds in exhaled breath condensate in order to guide methodology choices for exhaled breath condensate analysis studies. Four methods were explored to broaden the range of measured compounds across both the volatile and non-volatile domain. Liquid phase sampling with polyacrylate Solid-Phase MicroExtraction fiber, liquid phase extraction with a polydimethylsiloxane patch, and headspace sampling using Carboxen/Polydimethylsiloxane Solid-Phase MicroExtraction (SPME) followed by gas chromatography mass spectrometry were tested for the analysis of volatile fraction. Hydrophilic interaction liquid chromatography and reversed-phase chromatography high performance liquid chromatography mass spectrometry were used for analysis of non-volatile fraction. We found that liquid phase breath condensate extraction was notably superior compared to headspace extraction and differences in employed sorbents manifested altered metabolite coverages. The most pronounced effect was substantially enhanced metabolite capture for larger, higher-boiling compounds using polyacrylate SPME liquid phase sampling. The analysis of the non-volatile fraction of breath condensate by hydrophilic and reverse phase high performance liquid chromatography mass spectrometry indicated orthogonal metabolite coverage by these chromatography modes. We found that the metabolite coverage could be enhanced significantly with the use of organic solvent as a device rinse after breath sampling to collect the non-aqueous fraction as opposed to neat breath condensate sample. Here, we show the detected ranges of compounds in each case and provide a practical guide for methodology selection for optimal detection of specific compounds. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhang, Wei-Dong; Wang, Ying; Wang, Qing; Yang, Wan-Jun; Gu, Yi; Wang, Rong; Song, Xiao-Mei; Wang, Xiao-Juan
2012-08-01
A sensitive and reliable ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry has been developed and partially validated to evaluate the quality of Semen Cassiae (Cassia obtusifolia L.) through simultaneous determination of 11 anthraquinones and two naphtha-γ-pyrone compounds. The analysis was achieved on a Poroshell 120 EC-C(18) column (100 mm × 2.1 mm, 2.7 μm; Agilent, Palo Alto, CA, USA) with gradient elution using a mobile phase that consisted of acetonitrile-water (30 mM ammonium acetate) at a flow rate of 0.4 mL/min. For quantitative analysis, all calibration curves showed perfect linear regression (r(2) > 0.99) within the testing range. This method was also validated with respect to precision and accuracy, and was successfully applied to quantify the 13 components in nine batches of Semen Cassiae samples from different areas. The performance of developed method was compared with that of conventional high-performance liquid chromatography method. The significant advantages of the former include high-speed chromatographic separation, four times faster than high-performance liquid chromatography with conventional columns, and great enhancement in sensitivity. This developed method provided a new basis for overall assessment on quality of Semen Cassiae. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
75 FR 22240 - Cyprodinil; Pesticide Tolerances
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-28
... chromatography with ultraviolet detector (HPLC/UV)) is available to enforce the tolerance expression on plant commodities. In addition, a high performance liquid chromatography with mass spectrometry (HPLC/MS) method...
Liu, Yong-Qiang; Yu, Hong
2017-04-01
A convenient and versatile method was developed for the separation and detection of alkaline earth metal ions by ion chromatography with indirect UV detection. The chromatographic separation of Mg 2+ , Ca 2+ , and Sr 2+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid as the mobile phase, in which the imidazolium ionic liquid acted as an UV-absorption reagent. The effects of imidazolium ionic liquids, detection wavelength, acids in the mobile phase, and column temperature on the retention of Mg 2+ , Ca 2+ , and Sr 2+ were investigated. The main factors influencing the separation and detection were the background UV absorption reagent and the concentration of hydrogen ion in ion chromatography with indirect UV detection. The successful separation and detection of Mg 2+ , Ca 2+ , and Sr 2+ within 14 min were achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.06, 0.12, and 0.23 mg/L, respectively. A new separation and detection method of alkaline earth metal ions by ion chromatography with indirect UV detection was developed, and the application range of ionic liquids was expanded. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.
Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel
2016-11-01
A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.
Wang, Yuanyuan; Li, Xiaowei; Zhang, Zhiwen; Ding, Shuangyang; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong; Xia, Xi
2016-02-01
A sensitive, confirmatory ultra-high performance liquid chromatography-tandem mass spectrometric method was developed and validated to detect 23 veterinary drugs and metabolites (nitroimidazoles, benzimidazoles, and chloramphenicol components) in bovine milk. Compounds of interest were sequentially extracted from milk with acetonitrile and basified acetonitrile using sodium chloride to induce liquid-liquid partition. The extract was purified on a mixed mode solid-phase extraction cartridge. Using rapid polarity switching in electrospray ionization, a single injection was capable of detecting both positively and negatively charged analytes in a 9 min chromatography run time. Recoveries based on matrix-matched calibrations and isotope labeled internal standards for milk ranged from 51.7% to 101.8%. The detection limits and quantitation limits of the analytical method were found to be within the range of 2-20 ng/kg and 5-50 ng/kg, respectively. The recommended method is simple, specific, and reliable for the routine monitoring of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk samples. Copyright © 2015 Elsevier Ltd. All rights reserved.
Wiese, Steffen; Teutenberg, Thorsten; Schmidt, Torsten C
2012-01-27
In the present work it is shown that the linear elution strength (LES) model which was adapted from temperature-programming gas chromatography (GC) can also be employed for systematic method development in high-temperature liquid chromatography (HT-HPLC). The ability to predict isothermal retention times based on temperature-gradient as well as isothermal input data was investigated. For a small temperature interval of ΔT=40°C, both approaches result in very similar predictions. Average relative errors of predicted retention times of 2.7% and 1.9% were observed for simulations based on isothermal and temperature-gradient measurements, respectively. Concurrently, it was investigated whether the accuracy of retention time predictions of segmented temperature gradients can be further improved by temperature dependent calculation of the parameter S(T) of the LES relationship. It was found that the accuracy of retention time predictions of multi-step temperature gradients can be improved to around 1.5%, if S(T) was also calculated temperature dependent. The adjusted experimental design making use of four temperature-gradient measurements was applied for systematic method development of selected food additives by high-temperature liquid chromatography. Method development was performed within a temperature interval from 40°C to 180°C using water as mobile phase. Two separation methods were established where selected food additives were baseline separated. In addition, a good agreement between simulation and experiment was observed, because an average relative error of predicted retention times of complex segmented temperature gradients less than 5% was observed. Finally, a schedule of recommendations to assist the practitioner during systematic method development in high-temperature liquid chromatography was established. Copyright © 2011 Elsevier B.V. All rights reserved.
Quantitative analysis of benzodiazepines in vitreous humor by high-performance liquid chromatography
Bazmi, Elham; Behnoush, Behnam; Akhgari, Maryam; Bahmanabadi, Leila
2016-01-01
Objective: Benzodiazepines are frequently screened drugs in emergency toxicology, drugs of abuse testing, and in forensic cases. As the variations of benzodiazepines concentrations in biological samples during bleeding, postmortem changes, and redistribution could be biasing forensic medicine examinations, hence selecting a suitable sample and a validated accurate method is essential for the quantitative analysis of these main drug categories. The aim of this study was to develop a valid method for the determination of four benzodiazepines (flurazepam, lorazepam, alprazolam, and diazepam) in vitreous humor using liquid–liquid extraction and high-performance liquid chromatography. Methods: Sample preparation was carried out using liquid–liquid extraction with n-hexane: ethyl acetate and subsequent detection by high-performance liquid chromatography method coupled to diode array detector. This method was applied to quantify benzodiazepines in 21 authentic vitreous humor samples. Linear curve for each drug was obtained within the range of 30–3000 ng/mL with coefficient of correlation higher than 0.99. Results: The limit of detection and quantitation were 30 and 100 ng/mL respectively for four drugs. The method showed an appropriate intra- and inter-day precision (coefficient of variation < 10%). Benzodiazepines recoveries were estimated to be over 80%. The method showed high selectivity; no additional peak due to interfering substances in samples was observed. Conclusion: The present method was selective, sensitive, accurate, and precise for the quantitative analysis of benzodiazepines in vitreous humor samples in forensic toxicology laboratory. PMID:27635251
Ma, Shufeng; Hu, Liming; Ma, Chaoyang; Lv, Wenping; Wang, Hongxin
2014-09-01
A novel on-line three-dimensional liquid chromatography method was developed to separate four main flavonoids from Rhodiola rosea. Ethyl acetate/0.5 mol/L ionic liquid 1-butyl-3-methylimidazolium chloride aqueous solution was selected as the solvent system. In the first-dimension separation, the target flavonoids were entrapped and subsequently desorbed into the second-dimension high-speed countercurrent chromatographic column for separation. In the third-dimension chromatography, the residual ionic liquid in the four separated flavonoids was removed and the used ionic liquid was recovered. As a result, 35.1 mg of compound 1, 20.4 mg of compound 2, 8.5 mg of compound 3, and 10.6 mg of compound 4 were obtained from 1.53 g R. rosea extract. They were identified as rhodiosin, rhodionin, herbacetin, and kaempferol, respectively. The recovery of ionic liquid reached 99.1% of the initial amount. The results showed that this method is a powerful technology for the separation of R. rosea flavonoids and that the ionic-liquid-based solvent system has advantages over traditional solvent systems in renewable and environmentally friendly properties. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
2013-02-11
calibration curves was ±5%. Ion chromatography (IC) was used for analysis of perchlorate and other ionic targets. Analysis was carried out on a...The methods utilize liquid or gas chromatography , techniques that do not lend themselves well to portable devices and methods. Portable methods are...
Wei, Zuofu; Pan, Youzhi; Li, Lu; Huang, Yuyang; Qi, Xiaolin; Luo, Meng; Zu, Yuangang; Fu, Yujie
2014-11-01
A method based on matrix solid-phase dispersion extraction followed by ultra high performance liquid chromatography with tandem mass spectrometry is presented for the extraction and determination of phenolic compounds in Equisetum palustre. This method combines the high efficiency of matrix solid-phase dispersion extraction and the rapidity, sensitivity, and accuracy of ultra high performance liquid chromatography with tandem mass spectrometry. The influential parameters of the matrix solid-phase dispersion extraction were investigated and optimized. The optimized conditions were as follows: silica gel was selected as dispersing sorbent, the ratio of silica gel to sample was selected to be 2:1 (400/200 mg), and 8 mL of 80% methanol was used as elution solvent. Furthermore, a fast and sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the determination of nine phenolic compounds in E. palustre. This method was carried out within <6 min, and exhibited satisfactory linearity, precision, and recovery. Compared with ultrasound-assisted extraction, the proposed matrix solid-phase dispersion procedure possessed higher extraction efficiency, and was more convenient and time saving with reduced requirements on sample and solvent amounts. All these results suggest that the developed method represents an excellent alternative for the extraction and determination of active components in plant matrices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Dinç, Erdal; Ertekin, Zehra Ceren; Büker, Eda
2016-09-01
Two-way and three-way calibration models were applied to ultra high performance liquid chromatography with photodiode array data with coeluted peaks in the same wavelength and time regions for the simultaneous quantitation of ciprofloxacin and ornidazole in tablets. The chromatographic data cube (tensor) was obtained by recording chromatographic spectra of the standard and sample solutions containing ciprofloxacin and ornidazole with sulfadiazine as an internal standard as a function of time and wavelength. Parallel factor analysis and trilinear partial least squares were used as three-way calibrations for the decomposition of the tensor, whereas three-way unfolded partial least squares was applied as a two-way calibration to the unfolded dataset obtained from the data array of ultra high performance liquid chromatography with photodiode array detection. The validity and ability of two-way and three-way analysis methods were tested by analyzing validation samples: synthetic mixture, interday and intraday samples, and standard addition samples. Results obtained from two-way and three-way calibrations were compared to those provided by traditional ultra high performance liquid chromatography. The proposed methods, parallel factor analysis, trilinear partial least squares, unfolded partial least squares, and traditional ultra high performance liquid chromatography were successfully applied to the quantitative estimation of the solid dosage form containing ciprofloxacin and ornidazole. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita
2016-08-01
Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). Copyright © 2016 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
A novel, rapid and sensitive Ultra Performance Liquid-Chromatography tandem Mass-Spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin, flavin a...
Pirulli, D; Giordano, M; Lessi, M; Spanò, A; Puzzer, D; Zezlina, S; Boniotto, M; Crovella, S; Florian, F; Marangella, M; Momigliano-Richiardi, P; Savoldi, S; Amoroso, A
2001-06-01
Primary hyperoxaluria type 1 is an autosomal recessive disorder of glyoxylate metabolism, caused by a deficiency of alanine:glyoxylate aminotransferase, which is encoded by a single copy gene (AGXT. The aim of this research was to standardize denaturing high-performance liquid chromatography, a new, sensitive, relatively inexpensive, and automated technique, for the detection of AGXT mutation. Denaturing high-performance liquid chromatography was used to analyze in blind the AGXT gene in 20 unrelated Italian patients with primary hyperoxaluria type I previously studied by other standard methods (single-strand conformation polymorphism analysis and direct sequencing) and 50 controls. Denaturing high-performance liquid chromatography allowed us to identify 13 mutations and the polymorphism at position 154 in exon I of the AGXT gene. Hence the method is more sensitive and less time consuming than single-strand conformation polymorphism analysis for the detection of AGXT mutations, thus representing a useful and reliable tool for detecting the mutations responsible for primary hyperoxaluria type 1. The new technology could also be helpful in the search for healthy carriers of AGXT mutations amongst family members and their partners, and for screening of AGXT polymorphisms in patients with nephrolithiasis and healthy populations.
Gergov, M; Ojanperä, I; Vuori, E
2003-09-25
A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method is presented for the qualitative screening for 238 drugs in blood samples, which is considerably more than in previous methods. After a two-step liquid-liquid extraction and C(18) chromatography, the compounds were introduced into a triple quadrupole mass spectrometer equipped with a turbo ion spray ion source operating in the positive ionization mode. Identification was based on the compound's absolute retention time, protonated molecular ion, and one representative fragment ion obtained by multiple reaction monitoring (MRM) at an individually selected collision energy of 20, 35, or 50 eV. The limit of detection (LOD) for the majority of the compounds (80%) was < or = 0.05 mg/l, ranging from 0.002 mg/l (e.g., antihistamines) to 5 mg/l (acidic compounds), and for malathion it was 10 mg/l. The LOD values were sufficiently low to allow the majority of compounds to be detected at therapeutic concentrations in the blood.
Cavedal, Luiz E; Mendes, Fabiana D; Domingues, Claudia C; Patni, Anil K; Monif, Tausif; Reyar, Simrit; Pereira, Alberto Dos S; Mendes, Gustavo D; De Nucci, Gilberto
2007-01-01
A rapid, sensitive and specific method for quantifying clonazepam in human plasma using diazepam as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using a hexane/diethylether (20 : 80, v/v) solution. The extracts were analysed by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed on a Jones Genesis C8 4 microm analytical column (100 x 2.1 mm i.d.). The method had a chromatographic run time of 3.0 min and a linear calibration curve over the range 0.5-50 ng/ml (r2 > 0.9965). The limit of quantification was 0.5 ng/ml. This HPLC/MS/MS procedure was used to assess the bioequivalence of two clonazepam 2 mg tablet formulations (clonazepam test formulation from Ranbaxy Laboratories Ltd and Rivotril from Roche Laboratórios Ltda as standard reference formulation). Copyright 2006 John Wiley & Sons, Ltd.
Pirok, Bob W J; Knip, Jitske; van Bommel, Maarten R; Schoenmakers, Peter J
2016-03-04
In the late 19th century, newly invented synthetic dyes rapidly replaced the natural dyes on the market. The characterization of mixtures of these so-called early synthetic dyes is complicated through the occurrence of many impurities and degradation products. Conventional one-dimensional liquid chromatography does not suffice to obtain fingerprints with sufficient resolution and baseline integrity. Comprehensive two-dimensional liquid chromatography (LC×LC) is employed in this study, with ion-exchange chromatography in the first dimension and fast ion-pair liquid chromatography in the second. Retention in the first dimension is largely determined by the number of charges, while the selection of a small ion-pair reagent (tetramethylammonium hydroxide) in the second dimension causes retention to be largely determined by the molecular structure of the dye. As a result, there is a high degree of orthogonality of the two dimensions, similar to the values typically encountered in GC×GC. The proposed LC×LC method shows a theroretical peak capacity of about 2000 in an analysis time of about three hours. Clear, informative fingerprints are obtained that open a way to a more efficient characterization of dyes used in objects of cultural heritage. Copyright © 2016 Elsevier B.V. All rights reserved.
Kajiyama, Shin'ichiro; Harada, Kazuo; Fukusaki, Eiichiro; Kobayashi, Akio
2006-12-01
The molecular constituents of the petal pigments of the Torenia plant (Torenia hybrida) were analyzed on a single-cell basis by a combination of newly developed laser-microsampling and nano-flow liquid chromatography-electro spray ionization mass spectrometry (LC-ESIMS) techniques. Our method should provide a facile method for obtaining precise metabolic profiles of each cell in a single plant tissue.
Crews, Colin
2015-01-01
The principles and application of established and newer methods for the quantitative and semi-quantitative determination of ergot alkaloids in food, feed, plant materials and animal tissues are reviewed. The techniques of sampling, extraction, clean-up, detection, quantification and validation are described. The major procedures for ergot alkaloid analysis comprise liquid chromatography with tandem mass spectrometry (LC-MS/MS) and liquid chromatography with fluorescence detection (LC-FLD). Other methods based on immunoassays are under development and variations of these and minor techniques are available for specific purposes. PMID:26046699
Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar
2015-12-01
In present study, a simultaneous derivatization and air-assisted liquid-liquid microextraction method combined with gas chromatography-nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1-flouro-2,4-dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05-0.34 ng mL(-1) are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. Copyright © 2015 John Wiley & Sons, Ltd.
Nojavan, Yones; Kamankesh, Marzieh; Shahraz, Farzaneh; Hashemi, Maryam; Mohammadi, Abdorreza
2015-05-01
A novel technique for simultaneous determination of five folate derivatives in various food matrices was developed by ion pair-based dispersive liquid-liquid microextraction (IP-DLLME) combined with high-performance liquid chromatography (HPLC). In the proposed method, N-methyl-N,N-dioctyloctan-1-ammonium chloride (aliquat-336) was used as an ion-pair reagent. Effective variables of microextraction process were optimized. Under optimum conditions, the method yielded a linear calibration curve ranging from 1-200 ng g(-1) with correlation coefficients (r(2)) higher than 0.98. The relative standard deviation for the seven analyses was 5.2-7.4%. Enrichment factors for the five folates ranged between 108-135. Limits of detection were 2-4.1 ng g(-1). A comparison of this method with other methods described that the new proposed method is rapid and accurate, and gives very good enrichment factors and detection limits for determining five folate derivatives. The newly developed method was successfully applied for the determination of five folate derivatives in wheat flour, egg yolk and orange juice samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Baranowska, Irena; Wojciechowska, Iwona; Solarz, Natalia; Krutysza, Ewa
2014-01-01
This paper reports the development of a method for simultaneously determining five preservatives in cosmetics, cleaning agents and pharmaceuticals by fast liquid chromatography. Methylisothiazolinone, methylchloroisothiazolinone, benzyl alcohol, sodium benzoate and methylparaben were separated on a Chromolith Fast Gradient reversed-phase 18e column using gradient elution with acetonitrile and a 0.1% aqueous solution of formic acid, with a run time of 3 min. The preparation of solid and liquid samples included ultrasonic extraction with methanol with recoveries ranging from 69 to 119%. The developed method was used to analyze samples of cosmetics (66 samples), cleaning agents (five samples) and pharmaceutical industry products (17 samples).
Bodai, Zsolt; Szabó, Bálint Sámuel; Novák, Márton; Hámori, Susanne; Nyiri, Zoltán; Rikker, Tamás; Eke, Zsuzsanna
2014-10-15
A simple and fast analytical method was developed for the determination of six UV stabilizers (Cyasorb UV-1164, Tinuvin P, Tinuvin 234, Tinuvin 326, Tinuvin 327, and Tinuvin 1577) and five antioxidants (Irgafos 168, Irganox 1010, Irganox 3114, Irganox 3790, and Irganox 565) in milk. For sample preparation liquid-liquid extraction with low-temperature purification combined with centrifugation was used to remove fats, proteins, and sugars. After the cleanup step, the sample was analyzed with high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). External standard and matrix calibrations were tested. External calibration proved to be acceptable for Tinuvin P, Tinuvin 234, Tinuvin 326, Tinuvin 327, Irganox 3114, and Irganox 3790. The method was successfully validated with matrix calibration for all compounds. Method detection limits were between 0.25 and 10 μg/kg. Accuracies ranged from 93 to 109%, and intraday precisions were <13%.
Bathena, Sai P; Huang, Jiangeng; Epstein, Adrian A; Gendelman, Howard E; Boska, Michael D; Alnouti, Yazen
2012-04-15
Amino acids and myo-inositol have long been proposed as putative biomarkers for neurodegenerative diseases. Accurate measures and stability have precluded their selective use. To this end, a sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method based on multiple reaction monitoring was developed to simultaneously quantify glutamine, glutamate, γ-aminobutyric acid (GABA), aspartic acid, N-acetyl aspartic acid, taurine, choline, creatine, phosphocholine and myo-inositol in mouse brain by methanol extractions. Chromatography was performed using a hydrophilic interaction chromatography silica column within in a total run time of 15 min. The validated method is selective, sensitive, accurate, and precise. The method has a limit of quantification ranging from 2.5 to 20 ng/ml for a range of analytes and a dynamic range from 2.5-20 to 500-4000 ng/ml. This LC-MS/MS method was validated for biomarker discovery in models of human neurological disorders. Copyright © 2012 Elsevier B.V. All rights reserved.
Serrano, Ana; van Bommel, Maarten; Hallett, Jessica
2013-11-29
An evaluation was undertaken of ultrahigh pressure liquid chromatography (UHPLC) in comparison to high-performance liquid chromatography (HPLC) for characterizing natural dyes in cultural heritage objects. A new UHPLC method was optimized by testing several analytical parameters adapted from prior UHPLC studies developed in diverse fields of research. Different gradient elution programs were tested on seven UHPLC columns with different dimensions and stationary phase compositions by applying several mobile phases, flow rates, temperatures, and runtimes. The UHPLC method successfully provided more improved data than that achieved by the HPLC method. Indeed, even though carminic acid has shown circa 146% higher resolution with HPLC, UHPLC resulted in an increase of 41-61% resolution and a decrease of 91-422% limit of detection, depending on the dye compound. The optimized method was subsequently assigned to analyse 59 natural reference materials, in which 85 different components were ascribed with different physicochemical properties, in order to create a spectral database for future characterization of dyes in cultural heritage objects. The majority of these reference samples could be successfully distinguished with one single method through the examination of these compounds' retention times and their spectra acquired with a photodiode array detector. These results demonstrate that UHPLC analyses are extremely valuable for the acquisition of more precise chromatographic information concerning natural dyes with complex mixtures of different and/or closely related physicochemical properties, essential for distinguishing similar species of plants and animals used to colour cultural heritage objects. Copyright © 2013 Elsevier B.V. All rights reserved.
Optimizing separations in online comprehensive two‐dimensional liquid chromatography
Gargano, Andrea F.G.; Schoenmakers, Peter J.
2017-01-01
Abstract Online comprehensive two‐dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two‐dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two‐dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high‐molecular‐weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one‐dimensional liquid chromatography, two‐dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two‐dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two‐dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two‐dimensional liquid chromatography separations. PMID:29027363
Çabuk, Hasan; Köktürk, Mustafa
2013-01-01
A simple and efficient method was established for the determination of synthetic antioxidants in beverages by using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography with ultraviolet detection. Butylated hydroxy toluene, butylated hydroxy anisole, and tert-butylhydroquinone were the antioxidants evaluated. Experimental parameters including extraction solvent, dispersive solvent, pH of sample solution, salt concentration, and extraction time were optimized. Under optimal conditions, the extraction recoveries ranged from 53 to 96%. Good linearity was observed by the square of correlation coefficients ranging from 0.9975 to 0.9997. The relative standard deviations ranged from 1.0 to 5.2% for all of the analytes. Limits of detection ranged from 0.85 to 2.73 ng mL−1. The method was successfully applied for determination of synthetic antioxidants in undiluted beverage samples with satisfactory recoveries. PMID:23853535
Kim, Hyo Seon; Chun, Jin Mi; Kwon, Bo-In; Lee, A-Reum; Kim, Ho Kyoung; Lee, A Yeong
2016-10-01
Ultra-performance convergence chromatography, which integrates the advantages of supercritical fluid chromatography and ultra high performance liquid chromatography technologies, is an environmentally friendly analytical method that uses dramatically reduced amounts of organic solvents. An ultra-performance convergence chromatography method was developed and validated for the quantification of decursinol angelate and decursin in Angelica gigas using a CSH Fluoro-Phenyl column (2.1 mm × 150 mm, 1.7 μm) with a run time of 4 min. The method had an improved resolution and a shorter analysis time in comparison to the conventional high-performance liquid chromatography method. This method was validated in terms of linearity, precision, and accuracy. The limits of detection were 0.005 and 0.004 μg/mL for decursinol angelate and decursin, respectively, while the limits of quantitation were 0.014 and 0.012 μg/mL, respectively. The two components showed good regression (correlation coefficient (r 2 ) > 0.999), excellent precision (RSD < 2.28%), and acceptable recoveries (99.75-102.62%). The proposed method can be used to efficiently separate, characterize, and quantify decursinol angelate and decursin in Angelica gigas and its related medicinal materials or preparations, with the advantages of a shorter analysis time, greater sensitivity, and better environmental compatibility. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ERIC Educational Resources Information Center
Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III
2015-01-01
Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…
Podhorniak, Lynda V; Kamel, Alaa; Rains, Diane M
2010-05-26
A rapid multiresidue method that captures residues of the insecticide formetanate hydrochloride (FHCl) in selected fruits is described. The method was used to provide residue data for dietary exposure determinations of FHCl. Using an acetonitrile extraction with a dispersive cleanup based on AOAC International method 2007.01, also known as QuEChERS, which was further modified and streamlined, thousands of samples were successfully analyzed for FHCl residues. FHCl levels were determined both by liquid chromatography-single-stage mass spectrometry (LC-MS) and ultraperformance liquid chromatography (UPLC)-tandem mass spectrometry (LC-MS/MS). The target limit of detection (LOD) and the limit of quantitation (LOQ) achieved for FHCl were 3.33 and 10 ng/g, respectively, with LC-MS and 0.1 and 0.3 ng/g, respectively, with LC-MS/MS. Recoveries at these previously unpublished levels ranged from 95 to 109%. A set of 20-40 samples can be prepared in one working day by two chemists.
Díaz, Laura; Llorca-Pórcel, Julio; Valor, Ignacio
2008-08-22
A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for the detection of pesticides in tap and treated wastewater was developed and validated according to the ISO/IEC 17025:1999. Key features of this method include direct injection of 100 microL of sample, an 11 min separation by means of a rapid resolution liquid chromatography system with a 4.6 mm x 50 mm, 1.8 microm particle size reverse phase column and detection by electrospray ionization (ESI) MS-MS. The limits of detection were below 15 ng L(-1) and correlation coefficients for the calibration curves in the range of 30-2000 ng L(-1) were higher than 0.99. Precision was always below 20% and accuracy was confirmed by external evaluation. The main advantages of this method are direct injection of sample without preparative procedures and low limits of detection that fulfill the requirements established by the current European regulations governing pesticide detection.
Viidanoja, Jyrki
2015-09-15
A new, sensitive and selective liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS/MS) method was developed for the analysis of Phospholipids (PLs) in bio-oils and fats. This analysis employs hydrophilic interaction liquid chromatography-scheduled multiple reaction monitoring (HILIC-sMRM) with a ZIC-cHILIC column. Eight PL class selective internal standards (homologs) were used for the semi-quantification of 14 PL classes for the first time. More than 400 scheduled MRMs were used for the measurement of PLs with a run time of 34min. The method's performance was evaluated for vegetable oil, animal fat and algae oil. The averaged within-run precision and between-run precision were ≤10% for all of the PL classes that had a direct homologue as an internal standard. The method accuracy was generally within 80-120% for the tested PL analytes in all three sample matrices. Copyright © 2015 Elsevier B.V. All rights reserved.
Raust, Jacques-Antoine; Bruell, Adele; Sinha, Pritish; Hiller, Wolf; Pasch, Harald
2010-09-01
A comprehensive two-dimensional liquid chromatography system was developed to precisely describe the molecular heterogeneity of fatty alcohol ethoxylates. The end-group functionality was analyzed by gradient HPLC while ethylene oxide oligomer distributions were characterized by liquid adsorption chromatography. A baseline separation of all functionality fractions irrespective of the ethylene oxide oligomer chain length was achieved on nonpolar X-Terra(®) C(18) with a methanol-water gradient, whereas an isocratic flow of isopropanol-water on a polar Chromolith(®) Si column gave a separation according to the oligomer chain length without interference of the end-group distribution. The combination of these two methods to conduct online two-dimensional liquid chromatography experiments resulted in a comprehensive two-dimensional picture on the molecular heterogeneity of the sample.
Electrochemical Detectors in HPLC and Ion Chromatography.
Horvai, George; Pungor, ErnÕ
1989-01-01
Back in 1952, the renowned Polish electrochemist Wiktor Kemula introduced chromato-polarography, 1 i.e., polaro-graphic detection for liquid chromatography. This technique continued to develop slowly until the early 1970s (for a review see Reference 2) when modem high-performance liquid chromatography (HPLC) emerged. This new, highly efficient chromatographc method could only be. used with detectors ensuring low dispersion. It was not easy to modify the dropping mercury electrode cells to satisfy this requirement. However, at the same time, electroanalytical chemists, who already had much experience in using carbon-based electrodes for oxidative detection in flow analysis, put forward the idea of oxidative amperometric detection in liquid chromatography. 3,4 In this technique, solid or quasi-solid (paste) electrodes were used and this made possible the construction of miniaturized cells with just a few microliter volume.
Razavi, Morteza; Frick, Lauren E; LaMarr, William A; Pope, Matthew E; Miller, Christine A; Anderson, N Leigh; Pearson, Terry W
2012-12-07
We investigated the utility of an SPE-MS/MS platform in combination with a modified SISCAPA workflow for chromatography-free MRM analysis of proteotypic peptides in digested human plasma. This combination of SISCAPA and SPE-MS/MS technology allows sensitive, MRM-based quantification of peptides from plasma digests with a sample cycle time of ∼7 s, a 300-fold improvement over typical MRM analyses with analysis times of 30-40 min that use liquid chromatography upstream of MS. The optimized system includes capture and enrichment to near purity of target proteotypic peptides using rigorously selected, high affinity, antipeptide monoclonal antibodies and reduction of background peptides using a novel treatment of magnetic bead immunoadsorbents. Using this method, we have successfully quantitated LPS-binding protein and mesothelin (concentrations of ∼5000 ng/mL and ∼10 ng/mL, respectively) in human plasma. The method eliminates the need for upstream liquid-chromatography and can be multiplexed, thus facilitating quantitative analysis of proteins, including biomarkers, in large sample sets. The method is ideal for high-throughput biomarker validation after affinity enrichment and has the potential for applications in clinical laboratories.
Hu, Xiaojian; Zhang, Haijing; Wang, Xiaohong; Ding, Changming; Lin, Shaobin
2015-05-01
To simultaneously determine the four bisphenolic compounds (bisphenol F, bisphenol A, tetrachlorobisphenol A and tetrabromobisphenol A) in drinking water by liquid chromatography tandem mass spectrometry. 200 ml water sample was extracted by solid-phase extraction, eluted with methanol and analyzed by liquid chromatography tandem mass spectrometry under the MRM mode. The separation was carried out on a T3 column (2.1 mm x 150 mm, 3 μm). The limits of detection for the four bisphenolic compounds were in the range of 0.20 - 5.5 ng/L. The mean recoveries at the two spiked levels were 87.1% - 109.0% with the intra-day precision between 6.3% - 12.4% and inter-day precision between 4.5% - 15.4%. The method was applied for determination of 15 water samples. The method was sensitive, precise and accurate.
Li, Senlin; Li, Sainan; Huang, Yu; Liu, Chunming; Chen, Lina; Zhang, Yuchi
2017-06-01
The separation of a compound of interest from its structurally similar homologues to produce high-purity natural products is a challenging problem. This work proposes a novel method for the separation of iristectorigenin A from its structurally similar homologues by ionic-liquid-based ultrasound-assisted extraction and the subsequent screening and isolation of potential α-glucosidase inhibitors via ultrafiltration and semipreparative high-performance liquid chromatography. Ionic-liquid-based ultrasound-assisted extraction was successfully applied to the extraction of tectorigenin, iristectorigenin A, irigenin, and irisflorentin from Belamcanda chinensis. The optimum conditions for the efficient extraction of isoflavones were determined as 1.0 M 1-ethyl-3-methylimidazolium tetrafluoroborate with extraction time of 30 min and a solvent to solid ratio of 30 mL/g. Ultrafiltration with liquid chromatography and mass spectrometry was applied to screen and identify α-glucosidase inhibitors from B. chinensis, followed by the application of semipreparative high-performance liquid chromatography to separate and isolate the active constituents. Four major compounds including tectorigenin, iristectorigenin A, irigenin, and irisflorentin were screened and identified as α-glucosidase inhibitors, and then the four active compounds abovementioned were subsequently isolated by semipreparative high-performance liquid chromatography (99.89, 88.97, 99.79, and 99.97% purity, respectively). The results demonstrate that ionic liquid extraction can be successfully applied to the extraction of isoflavones from B. chinensis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Pocock, Tessa; Król, Marianna; Huner, Norman P A
2004-01-01
Chorophylls and carotenoids are functionally important pigment molecules in photosynthetic organisms. Methods for the determination of chlorophylls a and b, beta-carotene, neoxanthin, and the pigments that are involved in photoprotective cycles such as the xanthophylls are discussed. These cycles involve the reversible de-epoxidation of violaxanthin into antheraxanthin and zeaxanthin, as well as the reversible de-epoxidation of lutein-5,6-epoxide into lutein. This chapter describes pigment extraction procedures from higher plants and green algae. Methods for the determination and quantification using high-performance liquid chromatograpy (HPLC) are described as well as methods for the separation and purification of pigments for use as standards using thin-layer chromatography (TLC). In addition, several spectrophotometric methods for the quantification of chlorophylls a and b are described.
Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen
2015-07-14
Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Yang, Xue-Dong; Tang, Xu-Yan; Sang, Lin
2012-11-01
To establish a method for rapid identification of micro-constituents in monoammonium glycyrrhizinate by high-pressure solid phase extraction-high performance liquid chromatography-mass spectrometry. HPLC preparative chromatograph was adopted for determining the optimal method for high-pressure solid phase extraction under optimal conditions. 5C18-MS-II column (20.0 mm x 20.0 mm) was used as the extraction column, with 35% acetonitrile-acetic acid solution (pH 2. 20) as eluent at the speed of 16 mL x min(-1). The sample size was 0.5 mL, and the extraction cycle was 4.5 min. Then, extract liquid was analyzed by high performance liquid chromatography-mass spectrometry (HPLC-MS) after being concentrated by 100 times. Under the optimal condition of high-pressure solid phase extraction-high performance liquid chromatography-mass spectrometry, 10 components were rapidly identified from monoammonium glycyrrhizinate raw materials. Among them, the chemical structures of six micro-constituents were identified as 3-O-[beta-D-glucuronopyranosyl-beta-D-glucuronopyranosyl]-30-0-beta-D-apiopyranosylglycyrrhetic/3-O- [P-D-glucuronopyranosyl-beta-D-glucuronopyranosyl]-30-O-beta-D-arabinopyranosylglycyrrhetic, glycyrrhizic saponin F3, 22-hydroxyglycyrrhizin/18alpha-glycyrrhizic saponin G2, 3-O-[beta-D-rhamnopyranosyl]-24-hydroxyglycyrrhizin, glycyrrhizic saponin J2, and glycyrrhizic saponin B2 by MS(n) spectra analysis and reference to literatures. Four main chemical components were identified as glycyrrhizic saponin G2, 18beta-glycyrrhizic acid, uralglycyrrhizic saponin B and 18alpha-glycyrrhizic acid by liquid chromatography, MS(n) and ultraviolet spectra information and comparison with reference substances. The method can be used to identify chemical constituents in monoammonium glycyrrhizinate quickly and effectively, without any reference substance, which provides basis for quality control and safe application of monoammonium glycyrrhizinate-related products.
ERIC Educational Resources Information Center
Revell, Kevin D.
2011-01-01
A new laboratory experiment is described in which students compare two benchtop separation methods to isolate the three active components of the commercial analgesic Excedrin. In the two-week sequence, aspirin, acetaminophen, and caffeine are separated using either a two-base liquid-liquid extraction or silica column chromatography. Students then…
Luo, Zhoufei; Lu, Jing; Li, Haipu; Tu, Yi; Wan, Yuehao; Yang, Zhaoguang
2018-09-15
A new, sensitive, and rapid method based on the Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) approach and air-assisted liquid-liquid microextraction (AALLME) technology was developed for the determination of 20 endocrine-disrupting compounds (EDCs) in fish by high-performance liquid chromatography-tandem mass spectrometry. The method first integrates AALLME into QuEChERS to achieve clean-up and enrichment of the EDCs in one step. A self-made glass tube was enfolded with plasticine to withstand the high centrifugal force. The established method was developed by optimization of the parameters. High linearities (R 2 > 0.9924) and recoveries (78.2-118.6%) at three spiked levels (5, 10, and 20 ng g -1 ), and low relative standard deviation values (1.1-14.5%) and limits of detection (0.03-0.80 ng g -1 ) were obtained. The method comparison shows that the proposed method is superior as it involves less organic solvent usage, simple operation and high efficiency. This method was successfully applied to different fishes for analyzing EDCs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Wang, Huayin
2014-09-01
A new quantitative technique for the simultaneous quantification of the individual anthocyanins based on the pH differential method and high-performance liquid chromatography with diode array detection is proposed in this paper. The six individual anthocyanins (cyanidin 3-glucoside, cyanidin 3-rutinoside, petunidin 3-glucoside, petunidin 3-rutinoside, and malvidin 3-rutinoside) from mulberry (Morus rubra) and Liriope platyphylla were used for demonstration and validation. The elution of anthocyanins was performed using a C18 column with stepwise gradient elution and individual anthocyanins were identified by high-performance liquid chromatography with tandem mass spectrometry. Based on the pH differential method, the high-performance liquid chromatography peak areas of maximum and reference absorption wavelengths of anthocyanin extracts were conducted to quantify individual anthocyanins. The calibration curves for these anthocyanins were linear within the range of 10-5500 mg/L. The correlation coefficients (r(2)) all exceeded 0.9972, and the limits of detection were in the range of 1-4 mg/L at a signal-to-noise ratio ≥5 for these anthocyanins. The proposed quantitative analysis was reproducible with good accuracy of all individual anthocyanins ranging from 96.3 to 104.2% and relative recoveries were in the range 98.4-103.2%. The proposed technique is performed without anthocyanin standards and is a simple, rapid, accurate, and economical method to determine individual anthocyanin contents. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Han, Zheng; Zheng, Yunliang; Chen, Na; Luan, Lianjun; Zhou, Changxin; Gan, Lishe; Wu, Yongjiang
2008-11-28
A new separation and quantification method using liquid chromatography under ultra-high-pressure in combination with tandem mass spectrometry (MS/MS) was developed for simultaneous determination of four alkaloids in Lindera aggregata. The analysis was performed on an Acquity UPLC BEH C(18) column (50mmx2.1mm, 1.7microm particle size; Waters, Milford, MA, USA) utilizing a gradient elution profile and a mobile phase consisting of (A) water containing 10mM ammonium acetate adjusted to pH 3 with acetic acid and (B) acetonitrile. An electrospray ionization (ESI)-tandem interface in the positive mode was employed prior to mass spectrometric detection. The calibration curve was linear over the range of 17.1-856ng for boldine, 42.4-2652ng for norboldine, 6.1-304ng for reticuline and 0.5-50ng for linderegatine, respectively. The average recoveries ranged from 99.2 to 101.4% with RSDs< or =2.7%. Then, four L. aggregata samples from different batches were analyzed using the established method. The results indicated that ultra-high-pressure liquid chromatography-tandem mass spectrometry provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LOQs) for most of target analytes compared to previous method employing conventional high-performance liquid chromatography (HPLC) separation. So, the established method was validated, sensitive and reliable for the determination of four alkaloids in L. aggregata.
Kalariya, Pradipbhai D; Kumar Talluri, Murali V N; Gaitonde, Vinay D; Devrukhakar, Prashant S; Srinivas, Ragampeta
2014-08-01
The present work describes the systematic development of a robust, precise, and rapid reversed-phase liquid chromatography method for the simultaneous determination of eprosartan mesylate and its six impurities using quality-by-design principles. The method was developed in two phases, screening and optimization. During the screening phase, the most suitable stationary phase, organic modifier, and pH were identified. The optimization was performed for secondary influential parameters--column temperature, gradient time, and flow rate using eight experiments--to examine multifactorial effects of parameters on the critical resolution and generated design space representing the robust region. A verification experiment was performed within the working design space and the model was found to be accurate. This study also describes other operating features of the column packed with superficially porous particles that allow very fast separations at pressures available in most liquid chromatography instruments. Successful chromatographic separation was achieved in less than 7 min using a fused-core C18 (100 mm × 2.1 mm, 2.6 μm) column with linear gradient elution of 10 mM ammonium formate (pH 3.0) and acetonitrile as the mobile phase. The method was validated for specificity, linearity, accuracy, precision, and robustness in compliance with the International Conference on Harmonization Q2 (R1) guidelines. The impurities were identified by liquid chromatography with mass spectrometry. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Du, Yan; Li, Yin-Jie; Hu, Xun-Xiu; Deng, Xu; Qian, Zeng-Ting; Li, Zheng; Guo, Meng-Zhe; Tang, Dao-Quan
2017-04-01
As essential endogenous compounds, nucleobases and nucleosides fulfill various functions in living organisms. This study presents the development and validation of a new hydrophilic interaction liquid chromatography tandem mass spectrometry method for simultaneous quantification of 19 nucleobases and nucleosides in rat plasma. For the sample preparation, 15 kinds of protein precipitants were evaluated according to the chromatographic profile and ion response of analytes. The optimization of chromatographic separation was respectively performed using reversed-phase liquid chromatography and hydrophilic interaction liquid chromatography mode; each separation mode included two test columns with different stationary phases. The chromatographic profile and parameters such as half-width (W 1/2 ), capacity factor (K') and tailing factor (f t ) were used to evaluate the separation efficiencies. Furthermore, the adopted composition of two mobile phase systems and the concentrations of the additives in the optimum buffer system were also investigated. The developed method was fully validated and successfully applied quantitatively to determine 19 nucleobases and nucleosides in plasma from normal and diabetic nephropathy (DN) rats. Significant differences between normal and DN rats were found in plasma levels of cytosine, xanthine, thymidine, adenosine, guanosine, inosine and 8-hydroxy-2'-deoxyguanosine. This information may provide a useful reference for the discovery of potential biomarkers of DN. Copyright © 2016 John Wiley & Sons, Ltd.
Ruan, Chunqiang; Zhao, Xiang; Liu, Chenglan
2015-09-01
In this study, a simple and low-organic-solvent-consuming method combining an acetonitrile-partitioning extraction procedure followed by "quick, easy, cheap, effective, rugged and safe" cleanup with ionic-liquid-based dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection was developed for the determination of diflubenzuron and chlorbenzuron in grapes and pears. Ionic-liquid-based dispersive liquid-liquid microextraction was performed using the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate as the extractive solvent and acetonitrile extract as the dispersive solvent. The main factors influencing the efficiency of the dispersive liquid-liquid microextraction were evaluated, including the extractive solvent type and volume and the dispersive solvent volume. The validation parameters indicated the suitability of the method for routine analyses of benzoylurea insecticides in a large number of samples. The relative recoveries at three spiked levels ranged between 98.6 and 109.3% with relative standard deviations of less than 5.2%. The limit of detection was 0.005 mg/kg for the two insecticides. The proposed method was successfully used for the rapid determination of diflubenzuron and chlorbenzuron residues in real fruit samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
USDA-ARS?s Scientific Manuscript database
A liquid chromatography-mass spectrometry (LC/MS) method for simultaneous quantitation of seven ergot alkaloids (lysergic acid, ergonovine, ergovaline, ergocornine, ergotamine, ergocryptine and ergocrystine) in vascular tissue was developed and validated. Reverse-phase chromatography, coupled to an...
NASA Astrophysics Data System (ADS)
Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi
2014-06-01
Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-01-01
The set of documents discusses the new draft methods (EPA method 551, EPA method 552) for the analysis of disinfection byproducts contained in drinking water. The methods use the techniques of liquid/liquid extraction and gas chromatography with electron capture detection.
Li, Xueqi; Woodman, Michael; Wang, Selina C
2015-08-01
Pheophytins and pyropheophytin are degradation products of chlorophyll pigments, and their ratios can be used as a sensitive indicator of stress during the manufacturing and storage of olive oil. They increase over time depending on the storage condition and if the oil is exposed to heat treatments during the refining process. The traditional analysis method includes solvent- and time-consuming steps of solid-phase extraction followed by analysis by high-performance liquid chromatography with ultraviolet detection. We developed an improved dilute/fluorescence method where multi-step sample preparation was replaced by a simple isopropanol dilution before the high-performance liquid chromatography injection. A quaternary solvent gradient method was used to include a fourth strong solvent wash on a quaternary gradient pump, which avoided the need to premix any solvents and greatly reduced the oil residues on the column from previous analysis. This new method not only reduces analysis cost and time but shows reliability, repeatability, and improved sensitivity, especially important for low-level samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ferry, Barbara; Gifu, Elena-Patricia; Sandu, Ioana; Denoroy, Luc; Parrot, Sandrine
2014-03-01
Electrochemical methods are very often used to detect catecholamine and indolamine neurotransmitters separated by conventional reverse-phase high performance liquid chromatography (HPLC). The present paper presents the development of a chromatographic method to detect monoamines present in low-volume brain dialysis samples using a capillary column filled with sub-2μm particles. Several parameters (repeatability, linearity, accuracy, limit of detection) for this new ultrahigh performance liquid chromatography (UHPLC) method with electrochemical detection were examined after optimization of the analytical conditions. Noradrenaline, adrenaline, serotonin, dopamine and its metabolite 3-methoxytyramine were separated in 1μL of injected sample volume; they were detected above concentrations of 0.5-1nmol/L, with 2.1-9.5% accuracy and intra-assay repeatability equal to or less than 6%. The final method was applied to very low volume dialysates from rat brain containing monoamine traces. The study demonstrates that capillary UHPLC with electrochemical detection is suitable for monitoring dialysate monoamines collected at high sampling rate. Copyright © 2014 Elsevier B.V. All rights reserved.
Yan, Xia; Wang, Li-Juan; Wu, Zhen; Wu, Yun-Long; Liu, Xiu-Xiu; Chang, Fang-Rong; Fang, Mei-Juan; Qiu, Ying-Kun
2016-10-15
Microbial metabolites represent an important source of bioactive natural products, but always exhibit diverse of chemical structures or complicated chemical composition with low active ingredients content. Traditional separation methods rely mainly on off-line combination of open-column chromatography and preparative high performance liquid chromatography (HPLC). However, the multi-step and prolonged separation procedure might lead to exposure to oxygen and structural transformation of metabolites. In the present work, a new two-dimensional separation workflow for fast isolation and analysis of microbial metabolites from Chaetomium globosum SNSHI-5, a cytotoxic fungus derived from extreme environment. The advantage of this analytical comprehensive two-dimensional liquid chromatography (2D-LC) lies on its ability to analyze the composition of the metabolites, and to optimize the separation conditions for the preparative 2D-LC. Furthermore, gram scale preparative 2D-LC separation of the crude fungus extract could be performed on a medium-pressure liquid chromatograph×preparative high-performance liquid chromatography system, under the optimized condition. Interestingly, 12 cytochalasan derivatives, including two new compounds named cytoglobosin Ab (3) and isochaetoglobosin Db (8), were successfully obtained with high purity in a short period of time. The structures of the isolated metabolites were comprehensively characterized by HR ESI-MS and NMR. To be highlighted, this is the first report on the combination of analytical and preparative 2D-LC for the separation of microbial metabolites. The new workflow exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Lee, Bohyoung; Weon, Jin Bae; Yun, Bo-Ra; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je
2014-01-01
Pyeongwee-San (PWS) has been widely used for treating acute gastritis, chronic, and gastritis. In this paper, simultaneous determination of five compounds (naringin, hesperidin, glycyrrhizin, atractylenolide III, and magnolol) from traditional medicine PWS using the high performance liquid chromatography (HPLC) was established for quality control. Optimum separations were obtained with a SHISEIDO C18 reverse-phase column by gradient elution with 0.1% Trifluoroacetic acid (TFA) water-acetonitrile as the mobile phase. The flow rate was 1 mL/min and detection wavelength was set at 205 nm and 250 nm. Validation of the analytical method was evaluated by linearity, precision, and accuracy test. The calibration curves were linear over the established range with R (2) > 0.9978. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.09 to 0.43 and 0.27 to 1.29 μg/mL. The method exhibited intra-day and inter-day precision range between 0.01-1.86% and 0.04-0.35% respectively. The recoveries of five compounds in PWS were in the range between 93.18-106.40%, and 0.20-1.51%. The application of this method was identified through the successful analysis of five compounds in 12 batches of PWS. In addition, identification of five compounds was confirmed by a liquid chromatography method and mass spectrometry. The HPLC method was could be accomplished to the quality control and stable experiment for the preparations consisted of five major compounds.
Optimizing separations in online comprehensive two-dimensional liquid chromatography.
Pirok, Bob W J; Gargano, Andrea F G; Schoenmakers, Peter J
2018-01-01
Online comprehensive two-dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two-dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two-dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high-molecular-weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one-dimensional liquid chromatography, two-dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two-dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two-dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two-dimensional liquid chromatography separations. © 2017 The Authors. Journal of Separation Science published by WILEY-VCH Verlag GmbH & Co. KGaA.
Guo, C; Hu, J-Y; Chen, X-Y; Li, J-Z
2008-02-01
An analytical method for the determination imazaquin residues in soybeans was developed. The developed liquid/liquid partition and strong anion exchange solid-phase extraction procedures provide the effective cleanup, removing the greatest number of sample matrix interferences. By optimizing mobile-phase pH water/acetonitrile conditions with phosphoric acid, using a C-18 reverse-phase chromatographic column and employing ultraviolet detection, excellent peak resolution was achieved. The combined cleanup and chromatographic method steps reported herein were sensitive and reliable for determining the imazaquin residues in soybean samples. This method is characterized by recovery >88.4%, precision <6.7% CV, and sensitivity of 0.005 ppm, in agreement with directives for method validation in residue analysis. Imazaquin residues in soybeans were further confirmed by high performance liquid chromatography-mass spectrometry (LC-MS). The proposed method was successfully applied to the analysis of imazaquin residues in soybean samples grown in an experimental field after treatments of imazaquin formulation.
Fan, Ruifang; Ramage, Robert; Wang, Dongli; Zhou, Junqiang; She, Jianwen
2012-05-15
The aim of this study is to develop and validate an analytical method for the quantitation of ten urinary monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) through high pressure liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). After enzymatic deconjugation, urine samples were extracted by liquid-liquid extraction (LLE) and OH-PAHs were analyzed by HPLC/MS/MS operated in negative electrospray ionization (ESI) and multiple reaction monitoring (MRM) mode. LLE was conducted with the solvent mixture of pentane and toluene, which reduced the matrix interferences and enhanced the method sensitivity significantly. Deuterated and (13)C-labeled analogs are used as internal standards. Calibration curves of all target analytes shows favorable linearity within the concentration range of 5.9-15,000.0 ng/L for different OH-PAHs with the regression coefficients above 0.993. The limits of detection (LODs) in pooled urine ranged from 1.72 to 17.47 ng/L, which were much lower than those obtained by a gas chromatography/high resolution mass spectrometry (GC/HRMS) method. The method shows satisfactory accuracy and precision when analyzing three different levels of OH-PAHs spiked in pooled urine. Except for 1-hydroxynaphthalene, recoveries of other OH-PAHs were in the range of 100 ± 20% with a variation coefficient of less than 13%. The measurement of OH-PAHs from a QC sample of the Centers for Disease Control and Prevention (CDC) generated results close to the values measured by CDC. This method has been successfully employed in the California Biomonitoring Program. Published by Elsevier B.V.
Xin, Li-Ping; Chai, Xin-Sheng; Hu, Hui-Chao; Barnes, Donald G
2014-09-05
This work demonstrates a novel method for rapid determination of total solid content in viscous liquid (polymer-enriched) samples. The method is based multiple headspace extraction gas chromatography (MHE-GC) on a headspace vial at a temperature above boiling point of water. Thus, the trend of water loss from the tested liquid due to evaporation can be followed. With the limited MHE-GC testing (e.g., 5 extractions) and a one-point calibration procedure (i.e., recording the weight difference before and after analysis), the total amount of water in the sample can be determined, from which the total solid contents in the liquid can be calculated. A number of black liquors were analyzed by the new method which yielded results that closely matched those of the reference method; i.e., the results of these two methods differed by no more than 2.3%. Compared with the reference method, the MHE-GC method is much simpler and more practical. Therefore, it is suitable for the rapid determination of the solid content in many polymer-containing liquid samples. Copyright © 2014 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
New, faster methods have been developed for analysis of vitamin D and triacylglycerols that eliminate hours of wet chemistry and preparative chromatography, while providing more information than classical methods for analysis. Unprecedented detail is provided by combining liquid chromatography with ...
Analytical methods for determination of mycotoxins: a review.
Turner, Nicholas W; Subrahmanyam, Sreenath; Piletsky, Sergey A
2009-01-26
Mycotoxins are small (MW approximately 700), toxic chemical products formed as secondary metabolites by a few fungal species that readily colonise crops and contaminate them with toxins in the field or after harvest. Ochratoxins and Aflatoxins are mycotoxins of major significance and hence there has been significant research on broad range of analytical and detection techniques that could be useful and practical. Due to the variety of structures of these toxins, it is impossible to use one standard technique for analysis and/or detection. Practical requirements for high-sensitivity analysis and the need for a specialist laboratory setting create challenges for routine analysis. Several existing analytical techniques, which offer flexible and broad-based methods of analysis and in some cases detection, have been discussed in this manuscript. There are a number of methods used, of which many are lab-based, but to our knowledge there seems to be no single technique that stands out above the rest, although analytical liquid chromatography, commonly linked with mass spectroscopy is likely to be popular. This review manuscript discusses (a) sample pre-treatment methods such as liquid-liquid extraction (LLE), supercritical fluid extraction (SFE), solid phase extraction (SPE), (b) separation methods such as (TLC), high performance liquid chromatography (HPLC), gas chromatography (GC), and capillary electrophoresis (CE) and (c) others such as ELISA. Further currents trends, advantages and disadvantages and future prospects of these methods have been discussed.
Bashiry, Moein; Mohammadi, Abdorreza; Hosseini, Hedayat; Kamankesh, Marzieh; Aeenehvand, Saeed; Mohammadi, Zaniar
2016-01-01
A novel method based on microwave-assisted extraction and dispersive liquid-liquid microextraction (MAE-DLLME) followed by high-performance liquid chromatography (HPLC) was developed for the determination of three polyamines from turkey breast meat samples. Response surface methodology (RSM) based on central composite design (CCD) was used to optimize the effective factors in DLLME process. The optimum microextraction efficiency was obtained under optimized conditions. The calibration graphs of the proposed method were linear in the range of 20-200 ng g(-1), with the coefficient determination (R(2)) higher than 0.9914. The relative standard deviations were 6.72-7.30% (n = 7). The limits of detection were in the range of 0.8-1.4 ng g(-1). The recoveries of these compounds in spiked turkey breast meat samples were from 95% to 105%. The increased sensitivity in using the MAE-DLLME-HPLC-UV has been demonstrated. Compared with previous methods, the proposed method is an accurate, rapid and reliable sample-pretreatment method. Copyright © 2015 Elsevier Ltd. All rights reserved.
Heo, Seok; Yoo, Geum Joo; Choi, Ji Yeon; Park, Hyoung Joon; Park, Sung-Kwan; Baek, Sun Young
2016-11-01
A novel, stable, simple and specific ultra-performance liquid chromatography method with ultraviolet detection (205 nm) for the simultaneous analysis of 25 anti-hypertensive substances was developed. The method was validated according to the International Conference of Harmonisation guidelines with respect to linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ) and stability. From the ultra-performance liquid chromatography results, we identified the LOD and LOQ of solid samples to be 0.20-1.00 and 0.60-3.00 μg ml -1 , respectively, while those of liquid samples were 0.30-1.20 and 0.90-3.60 μg ml -1 , respectively. The linearity exceeded 0.9999, and the intra- and inter-day precisions were 0.15-6.48% and 0.28-8.67%, respectively. The intra- and inter-day accuracies were 82.25-111.42% and 80.70-115.64%, respectively, and the stability was lower than 12.9% (relative standard deviation). This method was applied to the monitoring of 97 commercially available dietary supplements obtained in Korea, such as pills, soft capsules, hard capsules, liquids, powders and tablets. The proposed method is accurate, precise and of high quality, and can be used for the routine, reproducible analysis and control of 25 anti-hypertensive substances in various dietary supplements. The work presented herein may help to prevent incidents related to food adulteration and restrict the illegal food market.
Wang, Jixia; Kong, Song; Yan, Jingyu; Jin, Gaowa; Guo, Zhimou; Shen, Aijin; Xu, Junyan; Zhang, Xiuli; Zou, Lijuan; Liang, Xinmiao
2014-06-01
Peptide drugs play a critical role in therapeutic treatment. However, as the complexity of plasma, determination of peptide drugs using liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a daunting task. To solve this problem, hydrophilic interaction liquid chromatography-solid phase extraction (HILIC-SPE) directly combined with protein precipitation (PPT) was developed for the selective extraction of triptorelin from plasma. The extracts were analyzed by reversed-phase liquid chromatography (RPLC). Proteins, phospholipids and highly polar interferences could be removed from plasma by the efficient combination of PPT, HILIC-SPE and RPLC-MS/MS. This method was evaluated by matrix effect, recovery and process efficiency at different concentration levels (50, 500 and 5,000 ng/mL) of triptorelin. Furthermore, the performance of HILIC-SPE was compared with that of reversed-phase C18 SPE and hydrophilic lipophilic balance (Oasis HLB) SPE. Among them, HILIC-SPE provided the minimum matrix effect (ranging from 96.02% to 103.41%), the maximum recovery (ranging from 80.68% to 90.54%) and the satisfactory process efficiency (ranging from 82.83% to 92.95%). The validated method was successfully applied to determine triptorelin in rat plasma. Copyright © 2014 Elsevier B.V. All rights reserved.
Principles and Applications of Liquid Chromatography-Mass Spectrometry in Clinical Biochemistry
Pitt, James J
2009-01-01
Liquid chromatography-mass spectrometry (LC-MS) is now a routine technique with the development of electrospray ionisation (ESI) providing a simple and robust interface. It can be applied to a wide range of biological molecules and the use of tandem MS and stable isotope internal standards allows highly sensitive and accurate assays to be developed although some method optimisation is required to minimise ion suppression effects. Fast scanning speeds allow a high degree of multiplexing and many compounds can be measured in a single analytical run. With the development of more affordable and reliable instruments, LC-MS is starting to play an important role in several areas of clinical biochemistry and compete with conventional liquid chromatography and other techniques such as immunoassay. PMID:19224008
Zhang, Rui; Wang, Chuanliu; Yue, Qiaohong; Zhou, Tiecheng; Li, Na; Zhang, Hanqi; Hao, Xiaoke
2014-11-01
An ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction method was proposed for the extraction and concentration of 17-α-estradiol, 17-β-estradiol-benzoate, and quinestrol in environmental water samples by high-performance liquid chromatography with fluorescence detection. 1-Hexyl-3-methylimidazolium tetrafluoroborate was applied as foaming agent in the foam flotation process and dispersive solvent in microextraction. The introduction of the ion-pairing and salting-out agent NH4 PF6 was beneficial to the improvement of recoveries for the hydrophobic ionic liquid phase and analytes. Parameters of the proposed method including concentration of 1-hexyl-3-methylimidazolium tetrafluoroborate, flow rate of carrier gas, floatation time, types and concentration of ionic liquids, salt concentration in samples, extraction time, and centrifugation time were evaluated. The recoveries were between 98 and 105% with relative standard deviations lower than 7% for lake water and well water samples. The isolation of the target compounds from the water was found to be efficient, and the enrichment factors ranged from 4445 to 4632. This developing method is free of volatile organic solvents compared with regular extraction. Based on the unique properties of ionic liquids, the application of foam floatation, and dispersive liquid-liquid microextraction was widened. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Han, Shengli; Huang, Jing; Cui, Ronghua; Zhang, Tao
2015-02-01
Carthamus tinctorius, used in traditional Chinese medicine, has many pharmacological effects, such as anticoagulant effects, antioxidant effects, antiaging effects, regulation of gene expression, and antitumor effects. However, there is no report on the antiallergic effects of the components in C. tinctorius. In the present study, we investigated the antiallergic components of C. tinctorius and its mechanism of action. A rat basophilic leukemia 2H3/cell membrane chromatography coupled online with high-performance liquid chromatography and tandem mass spectrometry method was developed to screen antiallergic components from C. tinctorius. The screening results showed that Hydroxysafflor yellow A, from C. tinctorius, was the targeted component that retained on the rat basophilic leukemia 2H3/cell membrane chromatography column. We measured the amount of β-hexosaminidase and histamine released in mast cells and the key markers of degranulation. The release assays showed that Hydroxysafflor yellow A could attenuate the immunoglobulin E induced release of allergic cytokines without affecting cell viability from 1.0 to 50.0 μM. In conclusion, the established rat basophilic leukemia 2H3 cell membrane chromatography coupled with online high-performance liquid chromatography and tandem mass spectrometry method successfully screened and identified Hydroxysafflor yellow A from C. tinctorius as a potential antiallergic component. Pharmacological analysis elucidated that Hydroxysafflor yellow A is an effective natural component for inhibiting immunoglobulin E-antigen-mediated degranulation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chemical analysis of Panax quinquefolius (North American ginseng): A review.
Wang, Yaping; Choi, Hyung-Kyoon; Brinckmann, Josef A; Jiang, Xue; Huang, Linfang
2015-12-24
Panax quinquefolius (PQ) is one of the best-selling natural health products due to its proposed beneficial anti-aging, anti-cancer, anti-stress, anti-fatigue, and anxiolytic effects. In recent years, the quality of PQ has received considerable attention. Sensitive and accurate methods for qualitative and quantitative analyses of chemical constituents are necessary for the comprehensive quality control to ensure the safety and efficacy of PQ. This article reviews recent progress in the chemical analysis of PQ and its preparations. Numerous analytical techniques, including spectroscopy, thin-layer chromatography (TLC), gas chromatography (GC), high-performance liquid chromatography (HPLC), liquid chromatography/mass spectrometry (LC/MS), high-speed centrifugal partition chromatography (HSCPC), high-performance counter-current chromatography (HPCCC), nuclear magnetic resonance spectroscopy (NMR), and immunoassay, are described. Among these techniques, HPLC coupled with mass spectrometry (MS) is the most promising method for quality control. The challenges encountered in the chemical analysis of PQ are also briefly discussed, and the remaining questions regarding the quality control of PQ that require further investigation are highlighted. Copyright © 2015 Elsevier B.V. All rights reserved.
Liu, Cui-Ting; Zhang, Min; Yan, Ping; Liu, Hai-Chan; Liu, Xing-Yun; Zhan, Ruo-Ting
2016-01-01
Zhengtian pills (ZTPs) are traditional Chinese medicine (TCM) which have been commonly used to treat headaches. Volatile components of ZTPs extracted by ethyl acetate with an ultrasonic method were analyzed by gas chromatography mass spectrometry (GC-MS). Twenty-two components were identified, accounting for 78.884% of the total components of volatile oil. The three main volatile components including protocatechuic acid, ferulic acid, and ligustilide were simultaneously determined using ultra-high performance liquid chromatography coupled with diode array detection (UHPLC-DAD). Baseline separation was achieved on an XB-C18 column with linear gradient elution of methanol-0.2% acetic acid aqueous solution. The UHPLC-DAD method provided good linearity (R (2) ≥ 0.9992), precision (RSD < 3%), accuracy (100.68-102.69%), and robustness. The UHPLC-DAD/GC-MS method was successfully utilized to analyze volatile components, protocatechuic acid, ferulic acid, and ligustilide, in 13 batches of ZTPs, which is suitable for discrimination and quality assessment of ZTPs.
Sun, Meng; Ren, Jing; Du, Hui; Zhang, Yanmin; Zhang, Jie; Wang, Sicen; He, Langchong
2010-10-15
We have developed an online analytical method that combines A431 cell membrane chromatography (A431/CMC) with high performance liquid chromatography and mass spectrometry (LC/MS) for identifying active components from Radix Caulophylli acting on human EGFR. Retention fractions on A431/CMC model were captured onto an enrichment column and the components were directly analyzed by combining a 10-port column switcher with an LC/MS system for separation and preliminary identification. Using Sorafenib tosylate as a positive control, taspine and caulophine from Radix Caulophylli were identified as the active molecules which could act on the EGFR. This A431/CMC-online-LC/MS method can be applied for screening active components acting on EGFR from traditional Chinese medicines exemplified by Radix Caulophylli and will be of great utility in drug discovery using natural medicinal herbs as a source of novel compounds. Copyright © 2010 Elsevier B.V. All rights reserved.
Nilsson, L G; Walldorf, B; Paulsen, O
1987-12-25
A method based on column liquid chromatography was developed for determination of plasma concentrations of erythromycin. PRP-1, a polymeric type of packing material suitable for chromatography and amperometric detection at high pH, was used. The effect of pH on the column performance and on the electrochemical response was studied. A pH of ca. 10 was found to be optimal. After extraction with tert.-butyl methyl ether, plasma concentrations down to 0.2 mumol/l could be measured, using automated sample injection. Oleandomycin was used as internal standard. The method was used for determination of plasma concentrations in a pharmacokinetic study under steady-state conditions.
You, Xiangwei; Chen, Xiaochu; Liu, Fengmao; Hou, Fan; Li, Yiqiang
2018-01-15
A novel and simple ionic liquid-based air-assisted liquid-liquid microextraction technique combined with high performance liquid chromatography was developed to analyze five fungicides in juice samples. In this method, ionic liquid was used instead of a volatile organic solvent as the extraction solvent. The emulsion was formed by pulling in and pushing out the mixture of aqueous sample solution and extraction solvent repeatedly using a 10mL glass syringe. No organic dispersive solvent was required. Under the optimized conditions, the limits of detection (LODs) were 0.4-1.8μgL -1 at a signal-to-noise ratio of 3. The limits of quantification (LOQs) set as the lowest spiking levels with acceptable recovery in juices were 10μgL -1 , except for fludioxonil whose LOQ was 20μgL -1 . The proposed method was applied to determine the target fungicides in juice samples, and acceptable recoveries ranging from 74.9% to 115.4% were achieved. Copyright © 2017. Published by Elsevier Ltd.
Cooper, A D; Stubbings, G W; Kelly, M; Tarbin, J A; Farrington, W H; Shearer, G
1998-07-03
An improved on-line metal chelate affinity chromatography-high-performance liquid chromatography (MCAC-HPLC) method for the determination of tetracycline antibiotics in animal tissues and egg has been developed. Extraction was carried out with ethyl acetate. The extract was then evaporated to dryness and reconstituted in methanol prior to on-line MCAC clean-up and HPLC-UV determination. Recoveries of tetracycline, oxytetracycline, demeclocycline and chlortetracycline in the range 42% to 101% were obtained from egg, poultry, fish and venison tissues spiked at 25 micrograms kg-1. Limits of detection less than 10 microgram kg-1 were estimated for all four analytes. This method has higher throughput, higher recovery and lower limits of detection than a previously reported on-line MCAC-HPLC method which involved aqueous extraction and solid-phase extraction clean-up.
Zhou, M; Miles, C J
1991-01-01
Oxyfluorfen and oxyfluorfen amine were determined by liquid chromatography (LC) with ultraviolet (UV) and photoconductivity detection (PCD). A simple extraction procedure acceptably recovered both analytes from garbanzo beans over a wide range of fortifications (0.05 to 20 ppm) (83 +/- 4 for oxyfluorfen; 85 +/- 4 for oxyfluorfen amine). Percent recoveries decreased slightly as the fortification level decreased. Both analytes could be determined simultaneously at a concentration greater than 0.2 ppm in garbanzo beans. Detection limits were 3 ng for oxyfluorfen and 100 ng for oxyfluorfen amine using LC/UV, and 12 ng for both oxyfluorfen and oxyfluorfen amine with LC/PCD. Different knitted reaction coils and photoreactors were evaluated. Photoproduct yields and identification were determined by ion chromatography. The LC/PCD method measures oxyfluorfen and oxyfluorfen amine separately and has a shorter analysis time, while the standard method using gas chromatography measures total residues and is more sensitive.
Kang, Kyungsu; Peng, Lei; Jung, Yu-Jin; Kim, Joo Yeon; Lee, Eun Ha; Lee, Hee Ju; Kim, Sang Min; Sung, Sang Hyun; Pan, Cheol-Ho; Choi, Yongsoo
2018-02-01
To develop a high-throughput screening system to measure the conversion of testosterone to dihydrotestosterone (DHT) in cultured human prostate cancer cells using turbulent flow chromatography liquid chromatography-triple quadrupole mass spectrometry (TFC-LC-TQMS). After optimizing the cell reaction system, this method demonstrated a screening capability of 103 samples, including 78 single compounds and 25 extracts, in less than 12 h without manual sample preparation. Consequently, fucoxanthin, phenethyl caffeate, and Curcuma longa L. extract were validated as bioactive chemicals that inhibited DHT production in cultured DU145 cells. In addition, naringenin boosted DHT production in DU145 cells. The method can facilitate the discovery of bioactive chemicals that modulate the DHT production, and four phytochemicals are potential candidates of nutraceuticals to adjust DHT levels in male hormonal dysfunction.
Pazos, Manuel; Otten, Christian; Vollmer, Waldemar
2018-03-20
Peptidoglycan encases the bacterial cytoplasmic membrane to protect the cell from lysis due to the turgor. The final steps of peptidoglycan synthesis require a membrane-anchored substrate called lipid II, in which the peptidoglycan subunit is linked to the carrier lipid undecaprenol via a pyrophosphate moiety. Lipid II is the target of glycopeptide antibiotics and several antimicrobial peptides, and is degraded by 'attacking' enzymes involved in bacterial competition to induce lysis. Here we describe two protocols using thin-layer chromatography (TLC) and high pressure liquid chromatography (HPLC), respectively, to assay the digestion of lipid II by phosphatases such as Colicin M or the LXG toxin protein TelC from Streptococcus intermedius . The TLC method can also monitor the digestion of undecaprenyl (pyro)phosphate, whereas the HPLC method allows to separate the di-, mono- or unphosphorylated disaccharide pentapeptide products of lipid II.
Pazos, Manuel; Otten, Christian; Vollmer, Waldemar
2018-01-01
Peptidoglycan encases the bacterial cytoplasmic membrane to protect the cell from lysis due to the turgor. The final steps of peptidoglycan synthesis require a membrane-anchored substrate called lipid II, in which the peptidoglycan subunit is linked to the carrier lipid undecaprenol via a pyrophosphate moiety. Lipid II is the target of glycopeptide antibiotics and several antimicrobial peptides, and is degraded by ‘attacking’ enzymes involved in bacterial competition to induce lysis. Here we describe two protocols using thin-layer chromatography (TLC) and high pressure liquid chromatography (HPLC), respectively, to assay the digestion of lipid II by phosphatases such as Colicin M or the LXG toxin protein TelC from Streptococcus intermedius. The TLC method can also monitor the digestion of undecaprenyl (pyro)phosphate, whereas the HPLC method allows to separate the di-, mono- or unphosphorylated disaccharide pentapeptide products of lipid II. PMID:29651453
Shi, Shu Yun; Zhang, Yu Ping; Zhou, Hong Hao; Huang, Ke Long; Jiang, Xin Yu
2010-01-01
An online rapid screening method, the high-performance liquid chromatography (HPLC)-diode array detector (DAD)-radical scavenging detection (RSD)-electrospray ionization (ESI)-mass spectroscopy (MS)/MS system, was developed for the screening and identification of radical scavengers from Neo-Taraxacum siphonanthum, a new species found in China in 1989. For further characterization, the target compounds were isolated by silica column chromatography, preparative high-performance liquid chromatography (HPLC), HSCCC, and Sephadex LH-20 column chromatography and elucidated on the basis of ultraviolet (UV), ESI-MS/MS, and nuclear magnetic resonance (NMR) spectroscopy, as well as the chemical analysis. Eighteen antioxidative polyphenols (5 caffeic acid derivatives and 13 flavonoid derivatives) were characterized from Neo-T. siphonanthum. The distribution of all compounds was discussed in a chemosystematic context, which suggested that the genera Neo-Taraxacum and Taraxacum might relate chemosystematically.
Razmi, Rasoul; Shahpari, Behrouz; Pourbasheer, Eslam; Boustanifar, Mohammad Hasan; Azari, Zhila; Ebadi, Amin
2016-11-01
A rapid and simple method for the extraction and preconcentration of ceftazidime in aqueous samples has been developed using dispersive liquid-liquid microextraction followed by high-performance liquid chromatography analysis. The extraction parameters, such as the volume of extraction solvent and disperser solvent, salt effect, sample volume, centrifuge rate, centrifuge time, extraction time, and temperature in the dispersive liquid-liquid microextraction process, were studied and optimized with the experimental design methods. Firstly, for the preliminary screening of the parameters the taguchi design was used and then, the fractional factorial design was used for significant factors optimization. At the optimum conditions, the calibration curves for ceftazidime indicated good linearity over the range of 0.001-10 μg/mL with correlation coefficients higher than the 0.98, and the limits of detection were 0.13 and 0.17 ng/mL, for water and urine samples, respectively. The proposed method successfully employed to determine ceftazidime in water and urine samples and good agreement between the experimental data and predictive values has been achieved. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Le Guellec, C; Gaudet, M L; Breteau, M
1998-11-20
We report a high-performance liquid chromatography method for clonazepam determination in plasma. The use of a synthetic silica-based stationary phase markedly improved clonazepam resolution compared to standard reversed-phase columns. A liquid-liquid extraction was used, associated with reversed-phase chromatography, gradient elution and ultraviolet detection. Accuracy and precision were satisfactory at therapeutic concentrations. Selectivity was studied for benzodiazepines or other antiepileptic drugs, with particular attention to newly marketed drugs i.e., gabapentine and vigabatrin. No interfering substance was evidenced. Under the conditions described, it was possible to quantify clonazepam at nanogram level even when carbamazepine was present at therapeutic concentrations.
Cabañero, Ana I; Recio, Jose L; Rupérez, Mercedes
2010-01-27
A novel procedure was established for the simultaneous characterization of wine glycerol and ethanol (13)C/(12)C isotope ratio, using liquid chromatography/isotope ratio mass spectrometry (LC-IRMS). Several parameters influencing separation of glycerol and ethanol from wine matrix were optimized. Results obtained for 35 Spanish samples exposed no significant differences and very strong correlations (r = 0.99) between the glycerol (13)C/(12)C ratios obtained by an alternative method (gas chromatography/isotope ratio mass spectrometry) and the proposed new methodology, and between the ethanol (13)C/(12)C ratios obtained by the official method (elemental analyzer/isotope ratio mass spectrometry) and the proposed new methodology. The accuracy of the proposed method varied from 0.01 to 0.19 per thousand, and the analytical precision was better than 0.25 per thousand. The new developed LC-IRMS method it is the first isotopic method that allows (13)C/(12)C determination of both analytes in the same run directly from a liquid sample with no previous glycerol or ethanol isolation, overcoming technical difficulties associated with complex sample treatment and improving in terms of simplicity and speed.
Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases
Kalmár, É; Kormányos, B.; Szakonyi, G.; Dombi, G.
2014-01-01
Suppositories are important tools for individual therapy, especially in paediatrics, and an instrumental assay method has become necessary for the quality control of dosage units. The aim of this work was to develop a rapid, effective high-performance liquid chromatography method to assay aminophenazone in extemporaneous suppositories prepared with two different suppository bases, adeps solidus and massa macrogoli. With a novel sample preparation method developed by the authors, 4-dimethylaminoantipyrine was determined in these suppository bases with 95-105% recovery. The measurements were carried out on a Shimadzu Prominence ultra high-performance liquid chromatography system equipped with a 20 μl sample loop. The separation was achieved on a Hypersil ODS column, with methanol, sodium acetate buffer (pH 5.5±0.05, 0.05 M, 60:40, v/v) as the mobile phase at a flow rate of 1.5 ml/min. The chromatograms were acquired at 253 nm. The chromatographic method was fully validated in accordance with current guidelines. The presented data demonstrate the successful development of a rapid, efficient and robust sample preparation and high-performance liquid chromatography method for the routine quality control of the dosage units of suppositories containing 4-dimethylaminoantipyrine. PMID:24799736
High-performance liquid chromatographic determination of ambroxol in human plasma.
Nobilis, M; Pastera, J; Svoboda, D; Kvêtina, J; Macek, K
1992-10-23
Ambroxol has been determined in biological fluids using a rapid and sensitive high-performance liquid chromatographic method. The samples prepared from plasma by liquid-liquid extraction were analysed on reversed-phase silica gel by competing-ion chromatography with ultraviolet detection. The method was applied to the determination of ambroxol levels in twelve healthy volunteers after oral administration of 90 mg of ambroxol in tablets of Mucosolvan and Ambrosan.
Huang, Tao; He, Jiang
2017-01-01
Extracellular vesicles (EVs) have recently attracted substantial attention due to the potential diagnostic and therapeutic relevance. Although a variety of techniques have been used to isolate and analyze EVs, it is still far away from satisfaction. Size-exclusion chromatography (SEC), which separates subjects by size, has been widely applied in protein purification and analysis. The purpose of this chapter is to show the applications of size-exclusion high-performance liquid chromatography (HPLC) as methods for EV characterization of impurities or contaminants of small size, and thus for quality assay for the purity of the samples of EVs.
Lima, Eliana Martins; Diniz, Danielle G Almeida; Antoniosi-Filho, Nelson R
2005-07-15
This paper describes the development of a gas chromatography (GC) method used for the assay of isotretinoin in its isolated form and in pharmaceutical formulations. Isotretinoin soft and hard gelatin capsules were prepared with various excipients. The performance of the proposed gas chromatography method was compared to that of traditional high performance liquid chromatography (HPLC) systems for this substance, and the GC parameters were established based on several preliminary tests, including thermal analysis of isotretinoin. Results showed that gas chromatography-flame ionization detector (GC-FID) exhibited a separation efficiency superior to that of HPLC, particularly for separating isotretinoin degradation products. This method was proven to be effectively applicable to stability evaluation assays of isotretinoin and isotretinoin based pharmaceuticals.
Lu, Shuaimin; Wu, Di; Li, Guoliang; Lv, Zhengxian; Gong, Peiwei; Xia, Lian; Sun, Zhiwei; Chen, Guang; Chen, Xuefeng; You, Jinmao; Wu, Yongning
2017-11-01
The intake of N-nitrosamines (NAs) from foodstuffs is considered to be an important influence factor for several cancers. But the rapid and sensitive screening of NAs remains a challenge in the field of food safety. Inspired by that, a sensitive and rapid method was demonstrated for determination of five NAs (Nitrosopyrrolidine, Nitrosodimethylamine, Nitrosodiethylamine, Nitrosodipropylamine and Nitrosodibutylamine) using dispersive liquid-liquid microextraction (DLLME) followed by high-performance liquid chromatography with fluorescence detection (HPLC-FLD). The NAs were firstly denitrosated and labeled by 2-(11H-benzo[a]carbazol-11-yl) ethyl carbonochloridate (BCEC-Cl) and finally enriched by DLLME. Furthermore, the main DLLME conditions were optimized systematically. Under the optimal conditions, satisfactory limits of detection (LODs) were obtained with a range of 0.01-0.07ngg -1 , which were significantly lower than the reported methods. The developed method showed many merits including rapidity, simplicity, high sensitivity and excellent selectivity, which shows a broad prospect in food safety analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effect of Genetic Database Comprehensiveness on Fractional Proteomics of Escherichia coli O157:H7
2014-01-01
proteins would be observed in the extracellular fraction. 15. SUBJECT TERMS Escherichia coli O157:H7 Liquid chromatography Mass spectrometry...Preparation ...............1 2.2 Liquid Chromatography /Mass Spectrometry Sample Preparation ....................2 2.3 Liquid Chromatography /Mass... Chromatography /Mass Spectrometry Sample Preparation. Samples were prepared for liquid chromatography tandem mass spectrometry (LC-MS/MS) in a similar
Meyer, M.T.; Bumgarner, J.E.; Varns, J.L.; Daughtridge, J.V.; Thurman, E.M.; Hostetler, K.A.
2000-01-01
Approximately one-half of the 50 000000 lb of antibiotics produced in the USA are used in agriculture. Because of the intensive use of antibiotics in the management of confined livestock operations, the potential exists for the transport of these compounds and their metabolites into our nation's water resources. A commercially available radioimmunoassay method, developed as a screen for tetracycline antibiotics in serum, urine, milk, and tissue, was adapted to analyze water samples at a detection level of approximately 1.0 ppb and a semiquantitative analytical range of 1-20 ppb. Liquid waste samples were obtained from 13 hog lagoons in three states and 52 surface- and ground-water samples were obtained primarily from areas associated with intensive swine and poultry production in seven states. These samples were screened for the tetracycline antibiotics by using the modified radioimmunoassay screening method. The radioimmunoassay tests yielded positive results for tetracycline antibiotics in samples from all 13 of the hog lagoons. Dilutions of 10-100-fold of the hog lagoon samples indicated that tetracycline antibiotic concentrations ranged from approximately 5 to several hundred parts per billion in liquid hog lagoon waste. Of the 52 surface- and ground-water samples collected all but two tested negative and these two samples contained tetracycline antibiotic concentrations less than 1 ppb. A new liquid chromatography/mass spectrometry method was used to confirm the radioimmunoassay results in 9 samples and also to identify the tetracycline antibiotics to which the radioimmunoassay test was responding. The new liquid chromatography/mass spectrometry method with online solid-phase extraction and a detection level of 0.5 ??g/l confirmed the presence of chlorotetracycline in the hog lagoon samples and in one of the surface-water samples. The concentrations calculated from the radioimmunoassay were a factor of 1-5 times less than those calculated by the liquid chromatography/mass spectrometry concentrations for chlorotetracycline. Copyright (C) 2000 Elsevier Science B.V.
Xing, Han-Zhu; Wang, Xia; Chen, Xiang-Feng; Wang, Ming-Lin; Zhao, Ru-Song
2015-05-01
A method combining accelerated solvent extraction with dispersive liquid-liquid microextraction was developed for the first time as a sample pretreatment for the rapid analysis of phenols (including phenol, m-cresol, 2,4-dichlorophenol, and 2,4,6-trichlorophenol) in soil samples. In the accelerated solvent extraction procedure, water was used as an extraction solvent, and phenols were extracted from soil samples into water. The dispersive liquid-liquid microextraction technique was then performed on the obtained aqueous solution. Important accelerated solvent extraction and dispersive liquid-liquid microextraction parameters were investigated and optimized. Under optimized conditions, the new method provided wide linearity (6.1-3080 ng/g), low limits of detection (0.06-1.83 ng/g), and excellent reproducibility (<10%) for phenols. Four real soil samples were analyzed by the proposed method to assess its applicability. Experimental results showed that the soil samples were free of our target compounds, and average recoveries were in the range of 87.9-110%. These findings indicate that accelerated solvent extraction with dispersive liquid-liquid microextraction as a sample pretreatment procedure coupled with gas chromatography and mass spectrometry is an excellent method for the rapid analysis of trace levels of phenols in environmental soil samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ryan, C M; Yarmush, M L; Tompkins, R G
1992-04-01
Polyethylene glycol 3350 (PEG 3350) is useful as an orally administered probe to measure in vivo intestinal permeability to macromolecules. Previous methods to detect polyethylene glycol (PEG) excreted in the urine have been hampered by inherent inaccuracies associated with liquid-liquid extraction and turbidimetric analysis. For accurate quantitation by previous methods, radioactive labels were required. This paper describes a method to separate and quantitate PEG 3350 and PEG 400 in human urine that is independent of radioactive labels and is accurate in clinical practice. The method uses sized regenerated cellulose membranes and mixed ion-exchange resin for sample preparation and high-performance liquid chromatography with refractive index detection for analysis. The 24-h excretion for normal individuals after an oral dose of 40 g of PEG 3350 and 5 g of PEG 400 was 0.12 +/- 0.04% of the original dose of PEG 3350 and 26.3 +/- 5.1% of the original dose of PEG 400.
We used chromatography modeling software to assist in HPLC method development, with the goal
of enhancing separations through the exclusive use of gradient time and column temperature. We
surveyed nine stationary phases for their utility in pigment purification and natur...
Wu, Lijie; Song, Ying; Hu, Mingzhu; Xu, Xu; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming
2015-01-01
A novel, simple, and environmentally friendly pretreatment method, ionic liquid magnetic bar liquid-phase microextraction, was developed for the determination of sulfonamides in butter samples by high-performance liquid chromatography. The ionic liquid magnetic bar was prepared by inserting a stainless steel wire into the hollow of a hollow fiber and immobilizing ionic liquid in the micropores of the hollow fiber. In the extraction process, the ionic liquid magnetic bars were used to stir the mixture of sample and extraction solvent and enrich the sulfonamides in the mixture. After extraction, the analyte-adsorbed ionic liquid magnetic bars were readily isolated with a magnet from the extraction system. It is notable that the present method was environmentally friendly since water and only several microliters of ionic liquid were used in the whole extraction process. Several parameters affecting the extraction efficiency were investigated and optimized, including the type of ionic liquid, sample-to-extraction solvent ratio, the number of ionic liquid magnetic bars, extraction temperature, extraction time, salt concentration, stirring speed, pH of the extraction solvent, and desorption conditions. The recoveries were in the range of 73.25-103.85 % and the relative standard deviations were lower than 6.84 %. The experiment results indicated that the present method was effective for the extraction of sulfonamides in high-fat content samples.
Wang, Lu; Tian, Xiaofei; Wei, Wenhao; Chen, Gong; Wu, Zhenqiang
2016-10-01
Guava leaves are used in traditional herbal teas as antidiabetic therapies. Flavonoids are the main active of Guava leaves and have many physiological functions. However, the flavonoid compositions and activities of Guava leaves could change due to microbial fermentation. A high-performance liquid chromatography time-of-flight electrospray ionization mass spectrometry method was applied to identify the varieties of the flavonoids in Guava leaves before and after fermentation. High-performance liquid chromatography, hierarchical cluster analysis and principal component analysis were used to quantitatively determine the changes in flavonoid compositions and evaluate the consistency and quality of Guava leaves. Monascus anka Saccharomyces cerevisiae fermented Guava leaves contained 2.32- and 4.06-fold more total flavonoids and quercetin, respectively, than natural Guava leaves. The flavonoid compounds of the natural Guava leaves had similarities ranging from 0.837 to 0.927. The flavonoid compounds from the Monascus anka S. cerevisiae fermented Guava leaves had similarities higher than 0.993. This indicated that the quality consistency of the fermented Guava leaves was better than that of the natural Guava leaves. High-performance liquid chromatography fingerprinting and chemometric analysis are promising methods for evaluating the degree of fermentation of Guava leaves based on quality consistency, which could be used in assessing flavonoid compounds for the production of fermented Guava leaves. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cho, Hyun-Deok; Kim, Unyong; Suh, Joon Hyuk; Eom, Han Young; Kim, Junghyun; Lee, Seul Gi; Choi, Yong Seok; Han, Sang Beom
2016-04-01
Analytical methods using high-performance liquid chromatography with diode array and tandem mass spectrometry detection were developed for the discrimination of the rhizomes of four Atractylodes medicinal plants: A. japonica, A. macrocephala, A. chinensis, and A. lancea. A quantitative study was performed, selecting five bioactive components, including atractylenolide I, II, III, eudesma-4(14),7(11)-dien-8-one and atractylodin, on twenty-six Atractylodes samples of various origins. Sample extraction was optimized to sonication with 80% methanol for 40 min at room temperature. High-performance liquid chromatography with diode array detection was established using a C18 column with a water/acetonitrile gradient system at a flow rate of 1.0 mL/min, and the detection wavelength was set at 236 nm. Liquid chromatography with tandem mass spectrometry was applied to certify the reliability of the quantitative results. The developed methods were validated by ensuring specificity, linearity, limit of quantification, accuracy, precision, recovery, robustness, and stability. Results showed that cangzhu contained higher amounts of atractylenolide I and atractylodin than baizhu, and especially atractylodin contents showed the greatest variation between baizhu and cangzhu. Multivariate statistical analysis, such as principal component analysis and hierarchical cluster analysis, were also employed for further classification of the Atractylodes plants. The established method was suitable for quality control of the Atractylodes plants. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Saito-Shida, Shizuka; Nemoto, Satoru; Matsuda, Rieko; Akiyama, Hiroshi
2016-11-01
A sensitive and reliable method for the simultaneous determination of hydroxycoumarin-type (brodifacoum, bromadiolone, coumatetralyl, and warfarin) and indandione-type (chlorophacinone, diphacinone, and pindone) rodenticides in agricultural products by gel permeation chromatography (GPC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. The procedure involved extraction of the rodenticides from samples with acetone, followed by liquid-liquid partitioning with hexane/ethyl acetate (1:1, v/v) and 10% sodium chloride aqueous solution, then cleanup using GPC, and finally, analysis using LC-MS/MS. High recoveries from the GPC column were obtained for all rodenticides tested using a mobile phase of acetone/cyclohexane/triethylamine (400:1600:1, v/v/v). An ODS column, which contains low levels of metal impurities, gave satisfactory peak shapes for both hydroxycoumarin- and indandione-type rodenticides in the LC-MS/MS separation. The average recoveries of rodenticides from eight agricultural foods (apple, eggplant, cabbage, orange, potato, tomato, brown rice, and soybean) fortified at 0.0005-0.001 mg/kg ranged from 76 to 116%, except for bromadiolone in orange (53%) and diphacinone in soybean (54%), and the relative standard deviations ranged from 1 to 16%. The proposed method effectively removed interfering components, such as pigments and lipids, and showed high selectivity. In addition, the matrix effects were negligible for most of the rodenticide/food combinations. The results suggest that the proposed method is reliable and suitable for determining hydroxycoumarin- and indandione-type rodenticides in agricultural products.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunschel, David S.; Valenzuela, Blandina R.; Kaiser, Brooke L. Deatherage
A variety of toxins are produced by marine and freshwater microorganisms that present a threat to human health. These toxins have diverse chemical properties and specifically, a range of hydrophobicity. Methods for extraction and identification of these toxins are often geared toward specific classes of toxin depending on the sample type. There is a need for a general method of toxin extraction and identification for screening samples where the likely toxin content is not known a priori. Here, we have applied a general method for metabolite extraction to toxin containing samples. This method was coupled with a simple dual liquidmore » chromatography approach for separating a broad range of toxins. This liquid chromatography approach was coupled to triple quadrupole and quadrupole time-of-flight MS/MS platforms. The method was testing on a fish matrix for recovery of palytoxin as well as marine corals for detection of natural mixtures of palytoxin analogues. The recovery of palytoxin was found to produce a linear response (R 2 of 0.95) when spiked into the fish matrix with a limit of quantitation of 2.5 ng/μL and recovery efficiency of 73% +/- 9%. The screening of corals revealed varying amount of palytoxin, and in one case, different palytoxin structural analogues. This demonstration illustrates the potential utility of this method for toxin extraction and detection.« less
Wunschel, David S.; Valenzuela, Blandina R.; Kaiser, Brooke L. Deatherage; ...
2018-05-09
A variety of toxins are produced by marine and freshwater microorganisms that present a threat to human health. These toxins have diverse chemical properties and specifically, a range of hydrophobicity. Methods for extraction and identification of these toxins are often geared toward specific classes of toxin depending on the sample type. There is a need for a general method of toxin extraction and identification for screening samples where the likely toxin content is not known a priori. Here, we have applied a general method for metabolite extraction to toxin containing samples. This method was coupled with a simple dual liquidmore » chromatography approach for separating a broad range of toxins. This liquid chromatography approach was coupled to triple quadrupole and quadrupole time-of-flight MS/MS platforms. The method was testing on a fish matrix for recovery of palytoxin as well as marine corals for detection of natural mixtures of palytoxin analogues. The recovery of palytoxin was found to produce a linear response (R 2 of 0.95) when spiked into the fish matrix with a limit of quantitation of 2.5 ng/μL and recovery efficiency of 73% +/- 9%. The screening of corals revealed varying amount of palytoxin, and in one case, different palytoxin structural analogues. This demonstration illustrates the potential utility of this method for toxin extraction and detection.« less
2016-04-01
QUANTIFICATION OF VX NERVE AGENT IN VARIOUS FOOD MATRICES BY SOLID-PHASE EXTRACTION ULTRA-PERFORMANCE...TITLE AND SUBTITLE Quantification of VX Nerve Agent in Various Food Matrices by Solid-Phase Extraction Ultra-Performance Liquid Chromatography... food matrices. The mixed-mode cation exchange (MCX) sorbent and Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) methods were used for
Ortega, Nàdia; Macià, Alba; Romero, Maria-Paz; Trullols, Esther; Morello, Jose-Ramón; Anglès, Neus; Motilva, Maria-Jose
2009-08-26
An improved chromatographic method was developed using ultra-performance liquid chromatography-tandem mass spectrometry to identify and quantify phenolic compounds and alkaloids, theobromine and caffeine, in carob flour samples. The developed method has been validated in terms of speed, sensitivity, selectivity, peak efficiency, linearity, reproducibility, limits of detection, and limits of quantification. The chromatographic method allows the identification and quantification of 20 phenolic compounds, that is, phenolic acids, flavonoids, and their aglycone and glucoside forms, together with the determination of the alkaloids, caffeine and theobromine, at low concentration levels all in a short analysis time of less than 20 min.
Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masayo; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Suzuki, Osamu; Seno, Hiroshi
2010-01-01
A rapid and sensitive method for analysis of blonanserin in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry is presented. After pretreatment of a plasma sample by solid-phase extraction, blonanserin was analyzed by the system with a C(18) column. This method gave satisfactory recovery rates, reproducibility, and good linearity of calibration curve in the range of 0.01-10.0 ng/mL for quality control samples spiked with blonanserin. The detection limit was as low as 1 pg/mL. This method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.
Jin, Chunfen; Viidanoja, Jyrki
2017-01-15
Existing liquid chromatography - mass spectrometry method for the analysis of short chain carboxylic acids was expanded and validated to cover also the measurement of glycerol from oils and fats. The method employs chloride anion attachment and two ions, [glycerol+ 35 Cl] - and [glycerol+ 37 Cl] - , as alternative quantifiers for improved selectivity of glycerol measurement. The averaged within run precision, between run precision and accuracy ranged between 0.3-7%, 0.4-6% and 94-99%, respectively, depending on the analyte ion and sample matrix. Selected renewable diesel feedstocks were analyzed with the method. Copyright © 2016 Elsevier B.V. All rights reserved.
Saraji, Mohammad; Mehrafza, Narges; Bidgoli, Ali Akbar Hajialiakbari; Jafari, Mohammad Taghi
2012-10-01
A method was established for the determination of desipramine in biological samples using liquid-liquid-liquid microextraction followed by in-syringe derivatization and gas chromatography-nitrogen phosphorus detection. The extraction method was based on the use of two immiscible organic solvents. n-Dodecane was impregnated in the pores of the hollow fiber and methanol was placed inside the lumen of the fiber as the acceptor phase. Acetic anhydride was used as the reagent for the derivatization of the analyte inside the syringe barrel. Parameters that affect the extraction efficiency (composition of donor and acceptor phase, ionic strength, sample temperature, and extraction time) as well as derivatization efficiency (amount of acetic anhydride and reaction time and temperature) were investigated. The limit of detection was 0.02 μg/L with intra and interday RSDs of 2.6 and 7.7%, respectively. The linearity of the method was in the range of 0.2-20 μg/L (r(2) = 0.9986). The method was successfully applied to determine desipramine in human plasma and urine. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Zhong; Ren, Fei; Zhang, Pan
2012-11-01
A method was developed for the determination of capsaicinoids (capsaicin, dihydrocapsaicin and synthetic capsaicin) and eugenol in waste-edible-oil extracted by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The capsaicinoids and eugenol in waste-edible-oil were extracted by methanol, and then separated by a SUPEL COSIL ABZ + Plus dC18 column (150 mm x4.6 mm, 5 microm). The analysis was performed by MS/MS with electrospray ionization in positive and negative ion modes with multiple reaction monitoring (MRM). The limits of detection for capsaicin, dihydrocapsaicin, synthetic capsaicin and eugenol were 0.02, 0.03, 0.03 and 0.6 microg/L, respectively. The good linear relationships were obtained in certain concentration ranges of capsaicinoids and eugenol. The relative standard deviations (RSDs, n=5) of same-worker and different-worker were less than 5%. The method is exclusive, sensitive and accurate, and can be used in waste-edible-oil determination.
21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...
21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...
21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...
21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...
21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...
Harju, Kirsi; Rapinoja, Marja-Leena; Avondet, Marc-André; Arnold, Werner; Schär, Martin; Burrell, Stephen; Luginbühl, Werner; Vanninen, Paula
2015-01-01
Saxitoxin (STX) and some selected paralytic shellfish poisoning (PSP) analogues in mussel samples were identified and quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Sample extraction and purification methods of mussel sample were optimized for LC-MS/MS analysis. The developed method was applied to the analysis of the homogenized mussel samples in the proficiency test (PT) within the EQuATox project (Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk). Ten laboratories from eight countries participated in the STX PT. Identification of PSP toxins in naturally contaminated mussel samples was performed by comparison of product ion spectra and retention times with those of reference standards. The quantitative results were obtained with LC-MS/MS by spiking reference standards in toxic mussel extracts. The results were within the z-score of ±1 when compared to the results measured with the official AOAC (Association of Official Analytical Chemists) method 2005.06, pre-column oxidation high-performance liquid chromatography with fluorescence detection (HPLC-FLD). PMID:26610567
Schmitz-Afonso, I.; Loyo-Rosales, J.E.; de la Paz Aviles, M.; Rattner, B.A.; Rice, C.P.
2003-01-01
A quantitative method for the simultaneous determination of octylphenol, nonylphenol and the corresponding ethoxylates (1 to 5) in biota is presented. Extraction methods were developed for egg and fish matrices based on accelerated solvent extraction followed by a solid-phase extraction cleanup, using octadecylsilica or aminopropyl cartridges. Identification and quantitation were accomplished by liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) and compared to the traditional liquid chromatography with fluorescence spectroscopy detection. LC-MS-MS provides high sensitivity and specificity required for these complex matrices and an accurate quantitation with the use of 13C-labeled internal standards. Quantitation limits by LC-MS-MS ranged from 4 to 12 ng/g in eggs, and from 6 to 22 ng/g in fish samples. These methods were successfully applied to osprey eggs from the Chesapeake Bay and fish from the Great Lakes area. Total levels found in osprey egg samples were up to 18 ng/g wet mass and as high as 8.2 ug/g wet mass in the fish samples.
Serroukh, Sonia; Huber, Patrick; Lallam, Abdelaziz
2018-01-19
Inverse liquid chromatography is a technique for studying solid/liquid interaction and most specifically for the determination of solute adsorption isotherm. For the first time, the adsorption behaviour of microfibrillated cellulose was assessed using inverse liquid chromatography. We showed that microfibrillated cellulose could adsorb 17 mg/g of tetrasulfonated optical brightening agent in typical papermaking conditions. The adsorbed amount of hexasulfonated optical brightening agent was lower (7 mg/g). The packing of the column with microfibrillated cellulose caused important axial dispersion (D a = 5e-7 m²/s). Simulation of transport phenomena in the column showed that neglecting axial dispersion in the analysis of the chromatogram caused significant error (8%) in the determination of maximum adsorbed amount. We showed that conventional chromatogram analysis technique such as elution by characteristic point could not be used to fit our data. Using a bi-Langmuir isotherm model improved the fitting, but did not take into account axial dispersion, thus provided adsorption parameters which may have no physical significance. Using an inverse method with a single Langmuir isotherm, and fitting the transport equation to the chromatogram was shown to provide a satisfactory fitting to the chromatogram data. In general, the inverse method could be recommended to analyse inverse liquid chromatography data for column packing with significant axial dispersion (D a > 1e-7 m²/s). Copyright © 2017 Elsevier B.V. All rights reserved.
Tolrà, R P; Alonso, R; Poschenrieder, C; Barceló, D; Barceló, J
2000-08-11
Liquid chromatography-atmospheric pressure chemical ionization mass spectrometry was used to identify glucosinolates in plant extracts. Optimization of the analytical conditions and the determination of the method detection limit was performed using commercial 2-propenylglucosinolate (sinigrin). Optimal values for the following parameters were determined: nebulization pressure, gas temperature, flux of drying gas, capillar voltage, corona current and fragmentor conditions. The method detection limit for sinigrin was 2.85 ng. For validation of the method the glucosinolates in reference material (rapeseed) from the Community Bureau of Reference Materials (BCR) were analyzed. The method was applied for the determination of glucosinolates in Thlaspi caerulescens plants.
Stragierowicz, Joanna; Daragó, Adam; Brzeźnicki, Sławomir; Kilanowicz, Anna
2017-07-26
Glutamate (Glu) and γ-aminobutyric acid (GABA) are the main neurotransmitters in the central nervous system for excitatory and inhibitory processes, respectively. Monitoring these neurotransmitters is an essential tool in establishing pathological functions, among others in terms of occupational exposure to toxic substances. We present modification of the HPLC (high-performance liquid chromatography) to the UPLC (ultra-performance liquid chromatography) method for the simultaneous determination of glutamate and γ-aminobutyric acid in a single injection. The isocratic separation of these neurotransmitter derivatives was performed on Waters Acquity BEH (ethylene bridged hybrid) C18 column with particle size of 1.7 μm at 35°C using a mobile phase consisting of 0.1 M acetate buffer (pH 6.0) and methanol (60:40, v/v) at a flow rate of 0.3 ml/min. The analytes were detected with the fluorescence detector (FLD) using derivatization with o-phthaldialdehyde (OPA), resulting in excitation at 340 nm and emission at 455 nm. Several validation parameters including linearity (0.999), accuracy (101.1%), intra-day precision (1.52-1.84%), inter-day precision (2.47-3.12%), limit of detection (5-30 ng/ml) and quantification (100 ng/ml) were examined. The developed method was also used for the determination of these neurotransmitters in homogenates of selected rat brain structures. The presented UPLC-FLD is characterized by shorter separation time (3.5 min), which is an adaptation of the similar HPLC methods and is an alternative for more expensive references techniques such as liquid chromatography coupled with tandem mass-spectrometry (LC-MS/MS) methods. Med Pr 2017;68(5):583-591. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Nakahara, Ryosuke; Satho, Yuhki; Itoh, Hiroki
2016-11-01
A method for determining nilotinib concentration in human plasma is proposed using high-performance liquid chromatography and ultraviolet detection. Nilotinib and the internal standard dasatinib were separated using a mobile phase of 0.5% Na 2 PO 4 H 2 O (pH 2.5)-acetonitrile-methanol (55:25:20, v/v/v) on a Capcell Pak C18 MG II column (250 × 4.6 mm) at a flow rate of 1.0 ml/min, and ultraviolet measurement at 250 nm. The calibration curve exhibited linearity over the nilotinib concentration range of 50-2,500 ng/ml at 250 nm, with relative standard deviations (n = 5) of 7.1%, 2.5%, and 2.9% for 250, 1,500, and 2,500 ng/ml, respectively. The detection limit for nilotinib was 5 ng/ml due to three blank determinations (ρ = 3). This method was successfully applied to assaying nilotinib in human plasma samples from patients with chronic myelogenous leukemia. In addition, we compared the results with those measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) at BML, Inc. (a commercial laboratory). A strong correlation was observed between the nilotinib concentrations measured by our high-performance liquid chromatographic method and those obtained by LC/MS-MS (r 2 = 0.988, P < 0.01). © 2016 Wiley Periodicals, Inc.
Kirschbaum, Katrin M; Grellner, Wolfgang; Rochholz, Gertrud; Musshoff, Frank; Madea, Burkhard
2011-03-01
Quaternary ammonium compounds pose an analytical challenge. Mebezonium, a muscle-relaxing agent contained in veterinary euthanasia solution T61, was analyzed in body fluids, organs, and injection sites of a veterinarian by liquid chromatography-tandem mass spectrometry (LC-MS-MS) method. Additionally, embutramide and tetracaine, which are two other active ingredients contained in T61, methadone, xylazine, and analgesics were detected by LC-MS-MS and high-performance liquid chromatography-ultraviolet detection methods. For detection of mebezonium a solid-phase extraction (SPE) combined with ionpairing reagent heptafluorobutyric acid was developed. Separation was achieved on Phenomenex Synergi Hydro RP C(18) column combined with ammonium formate buffer and acetonitrile (pH 3.5). To enrich other drugs, liquid-liquid extraction procedures were used. Most of these drugs were separated on a Restek Allure PFP Propyl column using the mentioned mobile phase. Mebezonium and embutramide were detected in femoral vein serum in concentrations of 10.9 and 2.0 mg/L, respectively. The concentration of xylazine and methadone in serum was 2.0 and 0.4 mg/L, respectively. The LC-MS-MS method with SPE combined with an ion-pairing reagent allowed the quantitation of mebezonium. Methadone was detected in toxic concentrations and was, in combination with xylazine and T61, considered to be the cause of death.
Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M
2018-07-20
Nine organophosphorus pesticides (OPPs) were determined in environmental waters from different origins using in situ ionic liquid dispersive liquid microextraction (IL-DLLME). This preconcentration technique was coupled to gas chromatography-mass spectrometry (GC-MS) using microvial insert thermal desorption, an approach that uses a thermal desorption injector as sample introduction system. The parameters affecting both the microextraction and sample injection steps were optimized. The proposed method showed good precision, with RSD values ranging from 4.1 to 9.7%, accuracy with recoveries in the 85-118% range, and sensitivity with DLs ranging from 5 to 16 ng L -1 . Copyright © 2017 Elsevier B.V. All rights reserved.
Analysis of street drugs in seized material without primary reference standards.
Laks, Suvi; Pelander, Anna; Vuori, Erkki; Ali-Tolppa, Elisa; Sippola, Erkki; Ojanperä, Ilkka
2004-12-15
A novel approach was used to analyze street drugs in seized material without primary reference standards. Identification was performed by liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS), essentially based on accurate mass determination using a target library of 735 exact monoisotopic masses. Quantification was carried out by liquid chromatography/chemiluminescence nitrogen detection (LC/CLND) with a single secondary standard (caffeine), utilizing the detector's equimolar response to nitrogen. Sample preparation comprised dilution, first with methanol and further with the LC mobile phase. Altogether 21 seized drug samples were analyzed blind by the present method, and results were compared to accredited reference methods utilizing identification by gas chromatography/mass spectrometry and quantification by gas chromatography or liquid chromatography. The 31 drug findings by LC/TOFMS comprised 19 different drugs-of-abuse, byproducts, and adulterants, including amphetamine and tryptamine designer drugs, with one unresolved pair of compounds having an identical mass. By the reference methods, 27 findings could be confirmed, and among the four unconfirmed findings, only 1 apparent false positive was found. In the quantitative analysis of 11 amphetamine, heroin, and cocaine findings, mean relative difference between the results of LC/CLND and the reference methods was 11% (range 4.2-21%), without any observable bias. Mean relative standard deviation for three parallel LC/CLND results was 6%. Results suggest that the present combination of LC/TOFMS and LC/CLND offers a simple solution for the analysis of scheduled and designer drugs in seized material, independent of the availability of primary reference standards.
Flores, Gema; Díaz-Plaza, Eva María; Cortés, Jose Manuel; Villén, Jesús; Herraiz, Marta
2008-11-21
The use of absorbents as retaining materials in the through oven transfer adsorption desorption interface (TOTAD) of an on-line coupled reversed-phase liquid chromatography-gas chromatography system (RPLC-GC) is proposed for the first time. A comparative study of an adsorbent (Tenax TA) and two absorbents, namely polydimethylsiloxane and poly(50% phenyl/50% methylsiloxane) is performed to establish the best experimental conditions for the automated and simultaneous determination of 15 organophosphorus and organochlorine pesticide residues in olive oil. The proposed method provides satisfactory repeatability (RSDs lower, in general, than 8.5%) and sensitivity (limits of detection ranging from 0.6 to 81.9 microg/L) for the investigated compounds.
Nanomaterials as stationary phases and supports in liquid chromatography.
Beeram, Sandya R; Rodriguez, Elliott; Doddavenkatanna, Suresh; Li, Zhao; Pekarek, Allegra; Peev, Darin; Goerl, Kathryn; Trovato, Gianfranco; Hofmann, Tino; Hage, David S
2017-10-01
The development of various nanomaterials over the last few decades has led to many applications for these materials in liquid chromatography (LC). This review will look at the types of nanomaterials that have been incorporated into LC systems and the applications that have been explored for such systems. A number of carbon-based nanomaterials and inorganic nanomaterials have been considered for use in LC, ranging from carbon nanotubes, fullerenes and nanodiamonds to metal nanoparticles and nanostructures based on silica, alumina, zirconia and titanium dioxide. Many ways have been described for incorporating these nanomaterials into LC systems. These methods have included covalent immobilization, adsorption, entrapment, and the synthesis or direct development of nanomaterials as part of a chromatographic support. Nanomaterials have been used in many types of LC. These applications have included the reversed-phase, normal-phase, ion-exchange, and affinity modes of LC, as well as related methods such as chiral separations, ion-pair chromatography and hydrophilic interaction liquid chromatography. Both small and large analytes (e.g., dyes, drugs, amino acids, peptides and proteins) have been used to evaluate possible applications for these nanomaterial-based methods. The use of nanomaterials in columns, capillaries and planar chromatography has been considered as part of these efforts. Potential advantages of nanomaterials in these applications have included their good chemical and physical stabilities, the variety of interactions many nanomaterials can have with analytes, and their unique retention properties in some separation formats. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liquid chromatographic assay of ceftizoxime in sera of normal and uremic patients.
McCormick, E M; Echols, R M; Rosano, T G
1984-01-01
The application of high-pressure liquid chromatography assays for cephalosporin serum concentrations is difficult in uremic patients because of interference from nondialyzable substances. We developed a high-pressure liquid chromatography method for determining the serum concentration of ceftizoxime in normal and uremic patients. The method involves protein precipitation with acetonitrile, followed by removal of the acetonitrile with dichloromethane. Separation was accomplished with a reverse-phase (C-18) column and a mobile phase of 13% acetonitrile and 2.8% acetic acid. UV detection at 310 nm was used to monitor the peaks. This assay produced a linear relationship between peak height ratio and ceftizoxime concentration from 1.5 to 100 micrograms/ml. Samples from 30 patients were assayed by this method and by a bioassay, with a good correlation of results (r = 0.9832). The method was applicable equally to normal and uremic serum samples. PMID:6326665
Extraction and characterization of montmorency (Prunus cerasus L.) sour cherry pit oil
USDA-ARS?s Scientific Manuscript database
Montmorency sour cherry (Prunus cerasus L.) pit oil was extracted and characterized by various methods including: gas chromatography (GC), liquid chromatography coupled with mass spectrometry (LC-MS), nuclear magnetic resonance (NMR), thermogravimetric analysis (TGA), differential scanning calorime...
Donkuru, McDonald; Michel, Deborah; Awad, Hanan; Katselis, George; El-Aneed, Anas
2016-05-13
Diquaternary gemini surfactants have successfully been used to form lipid-based nanoparticles that are able to compact, protect, and deliver genetic materials into cells. However, what happens to the gemini surfactants after they have released their therapeutic cargo is unknown. Such knowledge is critical to assess the quality, safety, and efficacy of gemini surfactant nanoparticles. We have developed a simple and rapid liquid chromatography electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the quantitative determination of various structures of gemini surfactants in cells. Hydrophilic interaction liquid chromatography (HILIC) was employed allowing for a short simple isocratic run of only 4min. The lower limit of detection (LLOD) was 3ng/mL. The method was valid to 18 structures of gemini surfactants belonging to two different structural families. A full method validation was performed for two lead compounds according to USFDA guidelines. The HILIC-MS/MS method was compatible with the physicochemical properties of gemini surfactants that bear a permanent positive charge with both hydrophilic and hydrophobic elements within their molecular structure. In addition, an effective liquid-liquid extraction method (98% recovery) was employed surpassing previously used extraction methods. The analysis of nanoparticle-treated cells showed an initial rise in the analyte intracellular concentration followed by a maximum and a somewhat more gradual decrease of the intracellular concentration. The observed intracellular depletion of the gemini surfactants may be attributable to their bio-transformation into metabolites and exocytosis from the host cells. Obtained cellular data showed a pattern that grants additional investigations, evaluating metabolite formation and assessing the subcellular distribution of tested compounds. Copyright © 2016 Elsevier B.V. All rights reserved.
Stravs, Michael A; Mechelke, Jonas; Ferguson, P Lee; Singer, Heinz; Hollender, Juliane
2016-03-01
Online solid-phase extraction was combined with nano-liquid chromatography coupled to high-resolution mass spectrometry (HRMS) for the analysis of micropollutants in environmental samples from small volumes. The method was validated in surface water, Microcystis aeruginosa cell lysate, and spent Microcystis growth medium. For 41 analytes, quantification limits of 0.1-28 ng/L (surface water) and 0.1-32 ng/L (growth medium) were obtained from only 88 μL of sample. In cell lysate, quantification limits ranged from 0.1-143 ng/L or 0.33-476 ng/g dry weight from a sample of 88 μL, or 26 μg dry weight, respectively. The method matches the sensitivity of established online and offline solid-phase extraction-liquid chromatography-mass spectrometry methods but requires only a fraction of the sample used by those techniques, and is among the first applications of nano-LC-MS for environmental analysis. The method was applied to the determination of bioconcentration in Microcystis aeruginosa in a laboratory experiment, and the benefit of coupling to HRMS was demonstrated in a transformation product screening.
Cabañero, Ana I; Recio, Jose L; Rupérez, Mercedes
2008-10-01
Two new procedures for wine ethanol 13C/12C isotope ratio determination, using high-performance liquid chromatography and gas chromatography isotope ratio mass spectrometry (HPLC/IRMS and GC/IRMS), have been developed to improve isotopic methods dedicated to the study of wine authenticity. Parameters influencing separation of ethanol from wine matrix such as column, temperature, mobile phase, flow rates and injection mode were investigated. Twenty-three wine samples from various origins were analyzed for validation of the procedures. The analytical precision was better than 0.15 per thousand, and no significant isotopic fractionation was observed employing both separative techniques coupled to IRMS. No significant differences and a very strong correlation (r = 0.99) were observed between the 13C/12C ratios obtained by the official method (elemental analyzer/isotope ratio mass spectrometry) and the proposed new methodology. The potential advantages of the developed methods over the traditional one are speed (reducing time required from hours to minutes) and simplicity. In addition, these are the first isotopic methods that allow 13C/12C determination directly from a liquid sample with no previous ethanol isolation, overcoming technical difficulties associated with sample treatment.
Vikingsson, Svante; Strömqvist, Malin; Svedberg, Anna; Hansson, Johan; Höiom, Veronica; Gréen, Henrik
2016-08-01
A novel, rapid and sensitive liquid chromatography tandem-mass spectrometry method for quantification of vemurafenib in human plasma, that also for the first time allows for metabolite semi-quantification, was developed and validated to support clinical trials and therapeutic drug monitoring. Vemurafenib was analysed by precipitation with methanol followed by a 1.9 min isocratic liquid chromatography tandem masspectrometry analysis using an Acquity BEH C18 column with methanol and formic acid using isotope labelled internal standards. Analytes were detected in multireaction monitoring mode on a Xevo TQ. Semi-quantification of vemurafenib metabolites was performed using the same analytical system and sample preparation with gradient elution. The vemurafenib method was successfully validated in the range 0.5-100 μg/mL according to international guidelines. The metabolite method was partially validated owing to the lack of commercially available reference materials. For the first time concentration levels at steady state for melanoma patients treated with vemurafenib is presented. The low abundance of vemurafenib metabolites suggests that they lack clinical significance. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Qiu, Huidong; Sun, Dongdi; Gunatilake, Sameera R; She, Jinyan; Mlsna, Todd E
2015-09-01
An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction. The extraction procedure (including loading, washing, and eluting) used a flow rate of 1.0mL/min, and dicyandiamide was eluted with 20mL of a methanol/acetonitrile mixture (V/V=2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography-ultraviolet spectroscopy (HPLC-UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge (with activated carbon). Separation was achieved on a ZIC(®)-Hydrophilic Interaction Liquid Chromatography (ZIC-HILIC) (50mm×2.1mm, 3.5μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions (R(2)>0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations (RSDs, n=3) were below 6.1% with a detection limit of 5.0ng/mL for stream water samples. Copyright © 2015. Published by Elsevier B.V.
Rezanka, Tomás; Nedbalová, Linda; Sigler, Karel; Cepák, Vladislav
2008-01-01
A method is described for the identification of astaxanthin glucoside esters from snow alga Chlamydomonas nivalis by means of liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization (LC-MS/APCI). The method is based on the use of preparative HPLC and subsequent identification of astaxanthin diglucoside diesters by microbore LC-MS/APCI. The combination of these two techniques was used to identify more than 100 molecular species. The astaxanthin diglucoside diester, i.e. (all-E)-[di-(6-O-oleoyl-beta-D-glucopyranosyloxy)]-astaxanthin, was also synthesized to unambiguously confirm its structure.
Zainudin, Badrul Hisyam; Salleh, Salsazali; Mohamed, Rahmat; Yap, Ken Choy; Muhamad, Halimah
2015-04-01
An efficient and rapid method for the analysis of pesticide residues in cocoa beans using gas and liquid chromatography-tandem mass spectrometry was developed, validated and applied to imported and domestic cocoa beans samples collected over 2 years from smallholders and Malaysian ports. The method was based on solvent extraction method and covers 26 pesticides (insecticides, fungicides, and herbicides) of different chemical classes. The recoveries for all pesticides at 10 and 50 μg/kg were in the range of 70-120% with relative standard deviations of less than 20%. Good selectivity and sensitivity were obtained with method limit of quantification of 10 μg/kg. The expanded uncertainty measurements were in the range of 4-25%. Finally, the proposed method was successfully applied for the routine analysis of pesticide residues in cocoa beans via a monitoring study where 10% of them was found positive for chlorpyrifos, ametryn and metalaxyl. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chang, Huichao; Li, Jinyin; Li, Ji; Guan, Xiaoduo; Sun, Fanlu; Qian, Zhongzhi; Bi, Kaishun; Fan, Guorong
2012-12-01
A sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was established for the quantitative determination of amlodipine and bisoprolol, using clenbuterol as the internal standard (IS). The analytes and IS were isolated from 100μL plasma samples by a simple liquid-liquid extraction (LLE). Reverse-phase high performance liquid chromatography (RP-HPLC) separation was accomplished on a Diamonsil C(18) column (50mm×4.6mm, 5μm) with a mobile phase composed of methanol-water-formic acid (75:25:0.01, v/v/v) at a flow rate of 0.3mL/min. The method had a chromatographic total run time of 3min. Multiple reacting monitoring (MRM) transitions of m/z [M+H](+) 409.1→237.9 (amlodipine), m/z [M+H](+) 326.2→116.0 (bisoprolol) and m/z [M+H](+) 277.0→203.0 (clenbuterol, IS) were used to quantify amlodipine, bisoprolol and IS, respectively. The method was sensitive with a lower limit of quantitation (LLOQ) of 0.2ng/mL for both amlodipine and bisoprolol, and the linear range was 0.2-50ng/mL for both amlodipine and bisoprolol (r(2)>0.9961). All the validation data, such as accuracy, precision and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic studies of amlodipine and bisoprolol in Sprague-Dawley (SD) rats. Copyright © 2012 Elsevier B.V. All rights reserved.
Dong, Shuya; He, Jiao; Hou, Huiping; Shuai, Yaping; Wang, Qi; Yang, Wenling; Sun, Zheng; Li, Qing; Bi, Kaishun; Liu, Ran
2017-12-01
A novel, improved, and comprehensive method for quality evaluation and discrimination of Herba Leonuri has been developed and validated based on normal- and reversed-phase chromatographic methods. To identify Herba Leonuri, normal- and reversed-phase high-performance thin-layer chromatography fingerprints were obtained by comparing the colors and R f values of the bands, and reversed-phase high-performance liquid chromatography fingerprints were obtained by using an Agilent Poroshell 120 SB-C18 within 28 min. By similarity analysis and hierarchical clustering analysis, we show that there are similar chromatographic patterns in Herba Leonuri samples, but significant differences in counterfeits and variants. To quantify the bio-active components of Herba Leonuri, reversed-phase high-performance liquid chromatography was performed to analyze syringate, leonurine, quercetin-3-O-robiniaglycoside, hyperoside, rutin, isoquercitrin, wogonin, and genkwanin simultaneously by single standard to determine multi-components method with rutin as internal standard. Meanwhile, normal-phase high-performance liquid chromatography was performed by using an Agilent ZORBAX HILIC Plus within 6 min to determine trigonelline and stachydrine using trigonelline as internal standard. Innovatively, among these compounds, bio-active components of quercetin-3-O-robiniaglycoside and trigonelline were first determined in Herba Leonuri. In general, the method integrating multi-chromatographic analyses offered an efficient way for the standardization and identification of Herba Leonuri. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Su, Rui; Li, Dan; Wu, Lijie; Han, Jing; Lian, Wenhui; Wang, Keren; Yang, Hongmei
2017-07-01
A novel microextraction method, termed microwave-assisted ionic liquid/ionic liquid dispersive liquid-liquid microextraction, has been developed for the rapid enrichment and analysis of triazine herbicides in fruit juice samples by high-performance liquid chromatography. Instead of using hazardous organic solvents, two kinds of ionic liquids, a hydrophobic ionic liquid (1-hexyl-3-methylimidazolium hexafluorophosphate) and a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate), were used as the extraction solvent and dispersion agent, respectively, in this method. The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of 1-hexyl-3-methylimidazolium hexafluorophosphate dispersed entirely into sample solution with the help of 1-butyl-3-methylimidazolium tetrafluoroborate. In addition, an ion-pairing agent (NH 4 PF 6 ) was introduced to improve recoveries of the ionic liquid phase. Several experimental parameters that might affect the extraction efficiency were investigated. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 5.00-250.00 μg/L, with the correlation coefficients of 0.9982-0.9997. The practical application of this effective and green method is demonstrated by the successful analysis of triazine herbicides in four juice samples, with satisfactory recoveries (76.7-105.7%) and relative standard deviations (lower than 6.6%). In general, this method is fast, effective, and robust to determine triazine herbicides in juice samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
2010-01-01
Chrom LC –MS...Literature 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE A liquid chromatographic–mass spectrometric ( LC –MS) method for the analysis of the 5a...Journal of Chromatography B journa l homepage: www.e lsev ier .com/ locate /chromb A liquid chromatographic–mass spectrometric ( LC –MS) method for
Peng, Li-Qing; Cao, Jun; Du, Li-Jing; Zhang, Qi-Dong; Shi, Yu-Tin; Xu, Jing-Jing
2017-05-26
An environmentally friendly ionic liquid-in-water (IL/W) microemulsion was established and applied as mobile phase in microemulsion liquid chromatography (MELC) with ultraviolet (UV) detection or electrochemical detector (ECD) for analysis of phenolic compounds in real samples. The optimal condition of the method was using the best composition of microemulsion (0.2% w/v [HMIM]PF 6 , 1.0% w/v SDS, 3.0% w/v n-butanol, 95.8% v/v water, pH 2.5) with UV detection. The validation results indicated that the method provided high degree of sensitivity, precision and accuracy with the low limit of detections ranged from 17.9-238ng/mL, satisfactory mean recovery values in the range of 80.1-105% and good linearity (r 2 >0.9994). Additionally, this method exhibited high selectivity and resolution for the analytes and was more eco-friendly compared with traditional MELC method. Consequently, the established IL/W MELC method was successfully applied to simultaneously separate and determine target compounds in Danshen sample and its preparation. Copyright © 2017 Elsevier B.V. All rights reserved.
Chu, Shang-Ping; Tseng, Wan-Chi; Kong, Po-Hsin; Huang, Chun-Kai; Chen, Jung-Hsuan; Chen, Pai-Shan; Huang, Shang-Da
2015-10-15
An up-and-down-shaker-assisted dispersive liquid-liquid microextraction (UDSA-DLLME) method coupled with gas chromatography-mass spectrometry was developed for the determination of fungicides (cyprodinil, procymidone, fludioxonil, flusilazole, benalaxyl, and tebuconazole) in wine. The developed method requires 11 μL of 1-octanol without the need for dispersive solvents. The total extraction time was approximately 3 min. Under optimum conditions, the linear range of the method was 0.05-100 μg L(-1) for all fungicides and the limit of detection was 0.007-0.025 μg L(-1). The absolute and relative recoveries were 31-83% and 83-107% for white wine, respectively, and 32-85% and 83-108% for red wine, respectively. The intra-day and inter-day precision were 0.5-7.5% and 0.7-6.1%, respectively. Our developed method had good sensitivity and high extraction efficiency. UDSA-DLLME is a desirable method in terms of performance and speed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Liang, Tu; Fu, Qing; Li, Fangbing; Zhou, Wei; Xin, Huaxia; Wang, Hui; Jin, Yu; Liang, Xinmiao
2015-08-01
A systematic strategy based on hydrophilic interaction liquid chromatography was developed for the separation, purification and quantification of raffinose family oligosaccharides from Lycopus lucidus Turcz. Methods with enough hydrophilicity and selectivity were utilized to resolve the problems encountered in the separation of oligosaccharides such as low retention, low resolution and poor solubility. The raffinose family oligosaccharides in L. lucidus Turcz. were isolated using solid-phase extraction followed by hydrophilic interaction liquid chromatography at semi-preparative scale to obtain standards of stachyose, verbascose and ajugose. Utilizing the obtained oligosaccharides as standards, a quantitative determination method was developed, validated and applied for the content determination of raffinose family oligosaccharides both in the aerial and root parts of L. lucidus Turcz. There were no oligosaccharides in the aerial parts, while in the root parts, the total content was 686.5 mg/g with the average distribution: raffinose 66.5 mg/g, stachyose 289.0 mg/g, verbascose 212.4 mg/g, and ajugose 118.6 mg/g. The result provided the potential of roots of L. lucidus Turcz. as new raffinose family oligosaccharides sources for functional food. Moreover, since the present systematic strategy is efficient, sensitive and robust, separation, purification and quantification of oligosaccharides by hydrophilic interaction liquid chromatography seems to be possible. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Naser, Fuad J; Mahieu, Nathaniel G; Wang, Lingjue; Spalding, Jonathan L; Johnson, Stephen L; Patti, Gary J
2018-02-01
Although it is common in untargeted metabolomics to apply reversed-phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC) methods that have been systematically optimized for lipids and central carbon metabolites, here we show that these established protocols provide poor coverage of semipolar metabolites because of inadequate retention. Our objective was to develop an RPLC approach that improved detection of these metabolites without sacrificing lipid coverage. We initially evaluated columns recently released by Waters under the CORTECS line by analyzing 47 small-molecule standards that evenly span the nonpolar and semipolar ranges. An RPLC method commonly used in untargeted metabolomics was considered a benchmarking reference. We found that highly nonpolar and semipolar metabolites cannot be reliably profiled with any single method because of retention and solubility limitations of the injection solvent. Instead, we optimized a multiplexed approach using the CORTECS T3 column to analyze semipolar compounds and the CORTECS C 8 column to analyze lipids. Strikingly, we determined that combining these methods allowed detection of 41 of the total 47 standards, whereas our reference RPLC method detected only 10 of the 47 standards. We then applied credentialing to compare method performance at the comprehensive scale. The tandem method showed more than a fivefold increase in credentialing coverage relative to our RPLC benchmark. Our results demonstrate that comprehensive coverage of metabolites amenable to reversed-phase separation necessitates two reconstitution solvents and chromatographic methods. Thus, we suggest complementing HILIC methods with a dual T3 and C 8 RPLC approach to increase coverage of semipolar metabolites and lipids for untargeted metabolomics. Graphical abstract Analysis of semipolar and nonpolar metabolites necessitates two reversed-phase chromatography (RPLC) methods, which extend metabolome coverage more than fivefold for untargeted profiling. HILIC hydrophilic interaction liquid chromatography.
Bär, W; Fricke, G
1987-01-01
A gas-liquid chromatographic method which requires no chloroform extraction of the split products has been investigated for the detection of hippurate hydrolysis by Campylobacter spp. This technique gave better reproducibility than other tests also used in this study and allows the routine use of the gas-liquid chromatographic method for identification of Campylobacter isolates. PMID:3654950
Weidolf, L O; Chichila, T M; Henion, J D
1988-12-09
Methods for screening by thin-layer chromatography, quantification by high-performance liquid chromatography with ultraviolet detection and confirmation by gas chromatography-mass spectrometry of boldenone sulfate in equine urine after administration of boldenone undecylenate (Equipoise) are presented. Sample work-up was done with C18 liquid-solid extraction followed by solvolytic cleavage of the sulfate ester. Confirmatory evidence of boldenone sulfate in equine urine was obtained from 2 h to 42 days following a therapeutic intramuscular dose of Equipoise. The use of 19-nortestosterone sulfate as the internal standard for quantification of boldenone sulfate is discussed.
Karr, Dale B.; Waters, James K.; Emerich, David W.
1983-01-01
Ion-exclusion high-pressure liquid chromatography (HPLC) was used to measure poly-β-hydroxybutyrate (PHB) in Rhizobium japonicum bacteroids. The products in the acid digest of PHB-containing material were fractionated by HPLC on Aminex HPX-87H ion-exclusion resin for organic acid analysis. Crotonic acid formed from PHB during acid digestion was detected by its intense absorbance at 210 nm. The Aminex-HPLC method provides a rapid and simple chromatographic technique for routine analysis of organic acids. Results of PHB analysis by Aminex-HPLC were confirmed by gas chromatography and spectrophotometric analysis. PMID:16346443
ERIC Educational Resources Information Center
Mulik, James D.; Sawicki, Eugene
1979-01-01
Accurate for the analysis of ions in solution, this form of analysis enables the analyst to directly assay many compounds that previously were difficult or impossible to analyze. The method is a combination of the methodologies of ion exchange, liquid chromatography, and conductimetric determination with eluant suppression. (Author/RE)
Use of Pseudophase TLC in Teaching Laboratories.
ERIC Educational Resources Information Center
Armstrong, Daniel W.; And Others
1984-01-01
Suggests that pseudophase liquid chromatography, which uses aqueous surfactant solutions instead of organic solvents for the mobile phase, can be substituted for thin-layer chromatography in the introductory organic course. Outlines the method as it applies to common separations in the laboratory. (JN)
[Advance in study on zearalenone's toxicity and determination].
He, Qing-Hua; Xu, Yang
2005-07-01
The article is intended to introduce the zearalenone's toxicity, determination methods and prevention. Zearalenone is one of the most widely distributed mycotoxins produces by Fusarium Species, it is harm to animals and human. And it can induce human liver cancer,carcinoma of tesis esophagus cancer. Now we use high-performance liquid chromatography, gas chromatography, thin layer chromatography, non-toxicity determinations to detect it.
Tokunaga, Takashi; Akagi, Ken-Ichi; Okamoto, Masahiko
2017-07-28
High performance liquid chromatography can be coupled with nuclear magnetic resonance (NMR) spectroscopy to give a powerful analytical method known as liquid chromatography-nuclear magnetic resonance (LC-NMR) spectroscopy, which can be used to determine the chemical structures of the components of complex mixtures. However, intrinsic limitations in the sensitivity of NMR spectroscopy have restricted the scope of this procedure, and resolving these limitations remains a critical problem for analysis. In this study, we coupled ultra-high performance liquid chromatography (UHPLC) with NMR to give a simple and versatile analytical method with higher sensitivity than conventional LC-NMR. UHPLC separation enabled the concentration of individual peaks to give a volume similar to that of the NMR flow cell, thereby maximizing the sensitivity to the theoretical upper limit. The UHPLC concentration of compound peaks present at typical impurity levels (5.0-13.1 nmol) in a mixture led to at most three-fold increase in the signal-to-noise ratio compared with LC-NMR. Furthermore, we demonstrated the use of UHPLC-NMR for obtaining structural information of a minor impurity in a reaction mixture in actual laboratory-scale development of a synthetic process. Using UHPLC-NMR, the experimental run times for chromatography and NMR were greatly reduced compared with LC-NMR. UHPLC-NMR successfully overcomes the difficulties associated with analyses of minor components in a complex mixture by LC-NMR, which are problematic even when an ultra-high field magnet and cryogenic probe are used. Copyright © 2017 Elsevier B.V. All rights reserved.
Du, Kunze; Li, Jin; Bai, Yun; An, Mingrui; Gao, Xiu-Mei; Chang, Yan-Xu
2018-04-01
A simple and green ionic liquid-based vortex-forced matrix solid phase dispersion (IL-VFMSPD) method was presented to simultaneously extract 5-hydroxymethyl furfurol (5-HMF) and iridoid glycosides in Fructus Corni by ultra-high performance liquid chromatography. Ionic liquid was used as a green elution reagent in vortex-forced MSPD process. A few parameters such as the type of ionic liquid, the type of sorbent, ratio of sample to sorbent, the concentration and volume of ionic liquid, grinding time and vortex time, were investigated in detail and an orthogonal design experiment was introduced to confirm the best conditions in this procedure. With the final optimized method, the recoveries of the target compounds in Fructus Corni were in the range of 95.2-103% (RSD<5.0%) and the method displayed a good linearity within the range of 0.8-200 μg mL -1 for morroniside, sweroside, loganin, cornuside and 1.2-300 μg mL -1 for 5-HMF. The limits of detection ranged from 0.02 to 0.08 μg mL -1 for all compounds. The results showed that the newly established method was efficiently applied to extract and determine iridoid glycosides and 5-HMF for quality control of Fructus Corni. Copyright © 2017 Elsevier Ltd. All rights reserved.
Campillo, Natalia; Iniesta, María Jesús; Viñas, Pilar; Hernández-Córdoba, Manuel
2015-01-01
Seven strobilurin fungicides were pre-concentrated from soya-based drinks using dispersive liquid-liquid micro-extraction (DLLME) with a prior protein precipitation step in acid medium. The enriched phase was analysed by liquid chromatography (LC) with dual detection, using diode array detection (DAD) and electrospray-ion trap tandem mass spectrometry (ESI-IT-MS/MS). After selecting 1-undecanol and methanol as the extractant and disperser solvents, respectively, for DLLME, the Taguchi experimental method, an orthogonal array design, was applied to select the optimal solvent volumes and salt concentration in the aqueous phase. The matrix effect was evaluated and quantification was carried out using external aqueous calibration for DAD and matrix-matched calibration method for MS/MS. Detection limits in the 4-130 and 0.8-4.5 ng g(-1) ranges were obtained for DAD and MS/MS, respectively. The DLLME-LC-DAD-MS method was applied to the analysis of 10 different samples, none of which was found to contain residues of the studied fungicides.
Ptácek, Pavel; Klíma, Josef; Macek, Jan
2009-03-15
A high-performance liquid chromatographic method with fluorescence detection for the determination of itopride in human plasma is reported. The sample preparation was based on liquid-liquid extraction of itopride from plasma with t-butylmethylether and dichloromethane (70:30, v/v) mixture followed by a back extraction of the analyte to the phosphate buffer (pH 3.2). Liquid chromatography was performed on an octadecylsilica column (55 mm x 4 mm, 3 microm particles), the mobile phase consisted of acetonitrile-triethylamine-15 mM dihydrogenpotassium phosphate (14.5:0.5:85, v/v/v), pH of the mobile phase was adjusted to 4.8. The run time was 3 min. The fluorimetric detector was operated at 250/342 nm (excitation/emission wavelength). Naratriptan was used as the internal standard. The limit of quantitation was 9.5 ng/ml using 0.5 ml of plasma. The method precision and inaccuracy were less than 8%. The assay was applied to the analysis of samples from a bioequivalence study.
NASA Astrophysics Data System (ADS)
Barakat, I. S. A.; Hammouri, M. K.; Habib, I.
2015-10-01
A potential method for simultaneous determination of vitamin A and vitamin D3 (25- hydroxyvitamin D3) in fresh milk samples is addressed. The method is based on combination of high performance liquid chromatography and mass spectrometry during the course of analysis. The method applied for determination of vitamins A and D3 on eighteen (18) different fresh milk samples using liquid chromatography along with tandem -mass spectrometry. The work describes the suitability of the proposed method for the simultaneous determination of both vitamins using LC-MS/MS as a specific and quantitative technique. The vitamins of milk were separated by C18 Thermo gold column(100mm × 4.6mm × 5 μm) with a flow rate of 1ml/min (using an isocratic mobile phase). The method was validated using duplicate analyses, relative recovery experiment, and comparative analysis with control samples. Liquid- liquid extraction was employed as a pre-concentration step with n-hexane - dichloromethane mixture (90%:10%) as an extraction solvent. The molecular ions (m/z) appeared near 286 and 385nm and for the base peaks were appeared near 255 and 355nm for vitamins A and D3. Good correlation coefficients were obtained, 0.9999 for vitamin D3 and 0.9994 for vitamin A. The limit of detection and the limit of quantification were found to be 0.09ng/ml and 0.54ng/ml for vitamin D3 and 0.32ng/ml and 1.8ng/ml and for vitamin A. The proposed method showed excellent recoveries, about 98% for both vitamins A and D3.
Wang, L Z; Goh, B C; Fan, L; Lee, H S
2004-01-01
The main toxicological concern of stevioside, a highly potent sweetener from S. rebaudiana, is its main metabolite, steviol. To determine very low levels of steviol in in vivo experiments, a sensitive liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS) method was developed for quantifying steviol in rat plasma after oral administration of a single dose of stevioside (0.5 g/kg). The sample preparation uses liquid-liquid extraction with tert-butyl methyl ether in an acidic environment. The retention time of steviol was 10.5 min. The assay was linear over the range 2-1000 ng/mL with a lower limit of detection of 1 ng/mL. The intra- and inter-day precision were <5 and <7%, respectively, and the accuracy was in the range 95-108%. The steviol concentration profile in rat plasma was determined. Copyright 2003 John Wiley & Sons, Ltd.
Yang, Cheng; Tian, Yuan; Zhang, Zunjian; Xu, Fengguo; Chen, Yun
2007-02-19
A selective and sensitive high-performance liquid chromatography-electrospray ionization mass spectrometry method has been developed for the determination of sodium ferulate in human plasma. The sample preparation was a liquid-liquid extraction and chromatographic separation was achieved with an Agilent ZORBAX SB-C(18) (3.5 microm, 100 mm x 3.0 mm) column, using a mobile phase of methanol-0.05% acetic acid 40:60 (v/v). Standard curves were linear (r(2)=0.9982) over the concentration range of 0.007-4.63 nM/ml and had acceptable accuracy and precision. The within- and between-batch precisions were within 12% relative standard deviation. The lower limit of quantification (LLOQ) was 0.007 nM/ml. The validated HPLC-ESI-MS method has been used successfully to study sodium ferulate pharmacokinetics, bioavailability and bioequivalence in 20 healthy volunteers.
Yoshida, Terumitsu; Takahashi, Ryohei; Imai, Koichi; Uchida, Hiroshi; Arai, Yasutoshi; Oh-ishi, Tsutomu
2010-03-01
This study developed a simple and sensitive method using reversed-phase high-performance liquid chromatography (HPLC) for ganciclovir (GCV) plasma concentrations in cytomegalovirus infectious infants with hearing loss. The method involves a simple protein precipitation procedure that uses no solid-phase or liquid-liquid extraction. The HPLC separation was carried out on a Cadenza CD-C(18) column (3 microm, 4.6 mm x 150 mm) with phosphate buffer (pH 2.5, 25 mM) containing 1% methanol-acetonitrile mixture (4:3, v/v) as a mobile phase at a 0.7 mL/min flow rate. GCV was detected using a fluorescence detection (lambdaex/em: 265/380 nm). The quantification limit was 0.025 microg/mL for 100 microL of plasma sample at which good intra- and inter-assay coefficient of variation values (< 4.96%) and recoveries (94.9-96.5%) were established.
London, Anne Serdakowski; Patel, Kunal; Quinn, Lisa; Lemmerer, Martin
2015-04-01
Coupled affinity liquid chromatography and size exclusion chromatography (ALC-SEC) is a technique that has been shown to successfully report product quality of proteins during cell expression and prior to the commencement of downstream processing chromatography steps. This method was applied to monitoring the degradation and subsequent partial remediation of a HSA-tagged protein which showed proteolysis, allowing for rapid cell line development to address this product quality dilemma. This paper outlines the novel application of this method for measuring and addressing protease-induced proteolysis. Copyright © 2014 Elsevier Inc. All rights reserved.
Ali, Arslan; Haq, Faraz Ul; Ul Arfeen, Qamar; Sharma, Khaga Raj; Adhikari, Achyut; Musharraf, Syed Ghulam
2017-10-01
Diabetes is a major global health problem which requires new studies for its prevention and control. Scoparia dulcis, a herbal product, is widely used for treatment of diabetes. Recent studies demonstrate coixol as a potent and nontoxic insulin secretagog from S. dulcis. This study focuses on developing two quantitative methods of coixol in S. dulcis methanol-based extracts. Quantification of coixol was performed using high-performance liquid chromatography-tandem mass spectrometry (method 1) and high-performance liquid chromatography-ultraviolet detection (method 2) with limits of detection of 0.26 and 11.6 pg/μL, respectively, and limits of quantification of 0.78 and 35.5 pg/μL, respectively. S. dulcis is rich in coixol content with values of 255.5 ± 2.1 mg/kg (method 1) and 220.4 ± 2.9 mg/kg (method 2). Excellent linearity with determination coefficients >0.999 was achieved for calibration curves from 10 to 7500 ng/mL (method 1) and from 175 to 7500 ng/mL (method 2). Good accuracy (bias < -8.6%) and precision (RSD < 8.5%) were obtained for both methods. Thus, they can be employed to analyze coixol in plant extracts and herbal formulations. Copyright © 2017 John Wiley & Sons, Ltd.
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
Zhao, Lu; Wen, E; Upur, Halmuart; Tian, Shuge
2017-01-01
Sea buckthorn ( Hippophae rhamnoides L.) as a traditional Chinese medicinal plant has various uses in Xinjiang. A reversed-phase rapid-resolution liquid-chromatography method with diode array detector was developed for simultaneous determination of protocatechuic acid, rutin, quercetin, kaempferol, and isorhamnetin in the pulp and seed of sea buckthorn, a widely used traditional Chinese medicine for promoting metabolism and treating scurvy and other diseases. Compounds were separated on an Agilent ZORBAX SB-C18 column (4.6 mm × 250 mm, 5 μm; USA) with gradient elution using methanol and 0.4% phosphoric acid (v/v) at 1.0 mL/min. Detection wavelength was set at 280 nm. The fruits of wild sea buckthorn were collected from Wushi County in Aksu, Xinjiang Province. The RSD of precision test of the five compounds were in the range of 0.60-2.22%, and the average recoveries ranged from 97.36% to 101.19%. Good linearity between specific chromatographic peak and component qualities were observed in the investigated ranges for all the analytes ( R 2 > 0.9997). The proposed method was successfully applied to determine the levels of five active components in sea buckthorn samples from Aksu in Xinjiang. The proposed method is simple, fast, sensitive, accurate, and suitable for quantitative assessment of the pulp and seed of sea buckthorn. Quantitative analysis method of protocatechuic acid, rutin, quercetin, kaempferol, and isorhamnetin in the extract of sea buckthorn pulp and seed is developed by high-performance liquid chromatography (HPLC) diode array detection.This method is simple and accurate; has strong specificity, good precision, and high recovery rate; and provides a reliable basis for further development of the substances in the pulp and seed of sea buckthorn.The method is widely used for content determination of active ingredients or physiologically active components in traditional Chinese medicine and its preparation Abbreviation used: PR: protocatechuic acid, RU: rutin, QU: quercetin, KA: kaempferol, IS: isorhamnetin, HPLC: high-performance liquid chromatography, HPLC-DAD: high performance liquid chromatographydiode array detector, LOD: linearity and limit of detection, LOQ: limit of quantitation, RSD: relative standard deviation.
Modern separation techniques coupled to high performance mass spectrometry for glycolipid analysis.
Sarbu, Mirela; Zamfir, Alina Diana
2018-01-21
Glycolipids (GLs), involved in biological processes and pathologies, such as viral, neurodegenerative and oncogenic transformations are in the focus of research related to method development for structural analysis. This review highlights modern separation techniques coupled to mass spectrometry (MS) for the investigation of GLs from various biological matrices. First section is dedicated to methods, which, although provide the separation in a non-liquid phase, are able to supply important data on the composition of complex mixtures. While classical thin layer chromatography (TLC) is useful for MS analyses of the fractionated samples, ultramodern ion mobility (IMS) characterized by high reproducibility facilitates to discover minor species and to apply low sample amounts, in addition to providing conformational separation with isomer discrimination. Second section highlights the advantages, applications and limitations of liquid-based separation techniques such as high performance liquid chromatography (HPLC) and hydrophilic interaction liquid chromatography (HILIC) in direct or indirect coupling to MS for glycolipidomics surveys. The on- and off-line capillary electrophoresis (CE) MS, offering a remarkable separation efficiency of GLs is also presented and critically assessed from the technical and application perspective in the final part of the review. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hoffman, Justin T; Rossi, Steven S; Espina-Quinto, Rowena; Letendre, Scott; Capparelli, Edmund V
2013-04-01
Previously published methods for determination of efavirenz (EFV) in human dried blood spots (DBS) use costly and complex liquid chromatography/mass spectrometry. We describe the validation and evaluation of a simple and inexpensive high-performance liquid chromatography method for EFV quantification in human DBS and dried plasma spots (DPS), using ultraviolet detection appropriate for resource-limited settings. One hundred microliters of heparinized whole blood or plasma were spotted onto blood collection cards, dried, punched, and eluted. Eluates are injected onto a C-18 reversed phase high-performance liquid chromatography column. EFV is separated isocratically using a potassium phosphate and acetonitrile mobile phase. Ultraviolet detection is at 245 nm. Quantitation is by use of external calibration standards. Following validation, the method was evaluated using whole blood and plasma from HIV-positive patients undergoing EFV therapy. Mean recovery of drug from DBS is 91.5%. The method is linear over the validated concentration range of 0.3125-20.0 μg/mL. A good correlation (Spearman r = 0.96) between paired plasma and DBS EFV concentrations from the clinical samples was observed, and hematocrit level was not found to be a significant determinant of the EFV DBS level. The mean observed C DBS/C plasma ratio was 0.68. A good correlation (Spearman r = 0.96) between paired plasma and DPS EFV concentrations from the clinical samples was observed. The mean percent deviation of DPS samples from plasma samples is 1.68%. Dried whole blood spot or dried plasma spot sampling is well suited for monitoring EFV therapy in resource-limited settings, particularly when high sensitivity is not essential.
Olofsson, Madelen A; Bylund, Dan
2015-10-01
A liquid chromatography with electrospray ionization mass spectrometry method was developed to quantitatively and qualitatively analyze 13 hydroxamate siderophores (ferrichrome, ferrirubin, ferrirhodin, ferrichrysin, ferricrocin, ferrioxamine B, D1 , E and G, neocoprogen I and II, coprogen and triacetylfusarinine C). Samples were preconcentrated on-line by a switch-valve setup prior to analyte separation on a Kinetex C18 column. Gradient elution was performed using a mixture of an ammonium formate buffer and acetonitrile. Total analysis time including column conditioning was 20.5 min. Analytes were fragmented by applying collision-induced dissociation, enabling structural identification by tandem mass spectrometry. Limit of detection values for the selected ion monitoring method ranged from 71 pM to 1.5 nM with corresponding values of two to nine times higher for the multiple reaction monitoring method. The liquid chromatography with mass spectrometry method resulted in a robust and sensitive quantification of hydroxamate siderophores as indicated by retention time stability, linearity, sensitivity, precision and recovery. The analytical error of the methods, assessed through random-order, duplicate analysis of soil samples extracted with a mixture of 10 mM phosphate buffer and methanol, appears negligible in relation to between-sample variations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Shin, Jeong-Sook; Peng, Lei; Kang, Kyungsu; Choi, Yongsoo
2016-09-09
Direct analysis of prostaglandin-E2 (PGE2) and -D2 (PGD2) produced from a RAW264.7 cell-based reaction was performed by liquid chromatography high-resolution mass spectrometry (LC-HRMS), which was online coupled with turbulent flow chromatography (TFC). The capability of this method to accurately measure PG levels in cell reaction medium containing cytokines or proteins as a reaction byproduct was cross-validated by two conventional methods. Two methods, including an LC-HRMS method after liquid-liquid extraction (LLE) of the sample and a commercial PGE2 enzyme-linked immunosorbent assay (ELISA), showed PGE2 and/or PGD2 levels almost similar to those obtained by TFC LC-HRMS over the reaction time after LPS stimulation. After the cross-validation, significant analytical throughputs, allowing simultaneous screening and potency evaluation of 80 natural products including 60 phytochemicals and 20 natural product extracts for the inhibition of the PGD2 produced in the cell-based inflammatory reaction, were achieved using the TFC LC-HRMS method developed. Among the 60 phytochemicals screened, licochalcone A and formononetin inhibited PGD2 production the most with IC50 values of 126 and 151nM, respectively. For a reference activity, indomethacin and diclofenac were used, measuring IC50 values of 0.64 and 0.21nM, respectively. This method also found a butanol extract of Akebia quinata Decne (AQ) stem as a promising natural product for PGD2 inhibition. Direct and accurate analysis of PGs in the inflammatory cell reaction using the TFC LC-HRMS method developed enables the high-throughput screening and potency evaluation of as many as 320 samples in less than 48h without changing a TFC column. Copyright © 2016 Elsevier B.V. All rights reserved.
Downey, Mark O; Rochfort, Simone
2008-08-01
A limitation of large-scale viticultural trials is the time and cost of comprehensive compositional analysis of the fruit by high-performance liquid chromatography (HPLC). In addition, separate methods have generally been required to identify and quantify different classes of metabolites. To address these shortcomings a reversed-phase HPLC method was developed to simultaneously separate the anthocyanins and flavonols present in grape skins. The method employs a methanol and water gradient acidified with 10% formic acid with a run-time of 48 min including re-equilibration. Identity of anthocyanins and flavonols in Shiraz (Vitis vinifera L.) skin was confirmed by mass spectral analysis.
Nicoletti, I; Corradini, C; Cogliandro, E; Cavazza, A
1999-08-01
This paper reports the results of a study carried out to develop a simple, rapid and sensitive method for the separation, identification and quantitative measurement of alpha-hydroxy acids in commercial cosmetics using high-performance liquid chromatography (HPLC). This method is successfully applied to the simultaneous identification and quantitative determination of glycolic, lactic, malic, tartaric and citric acids employing a reversed phase narrow-bore column under isocratic condition and UV detection. The method is validated by determining the precision of replicate analyses and accuracy by analyzing samples with and without adding know amount of the alpha-hydroxy acids. The procedure is suitable for routine analyses of commercial cosmetics.
Sakuma, R; Nishina, T; Kitamura, M
1987-08-01
We evaluated six deproteinizing methods for determination of uric acid in serum by "high-performance" liquid chromatography with ultraviolet detection: those involving zinc hydroxide, sodium tungstate, trichloroacetic acid, perchloric acid, acetonitrile, and centrifugal ultrafiltration (with Amicon MPS-1 devices). We used a Toyosoda ODS-120A reversed-phase column. The mobile phase was sodium phosphate buffer (40 mmol/L, pH 2.2) containing 20 mL of methanol per liter. Absorbance of the eluate was monitored at 284 nm. The precipitation method with perchloric acid gave high recoveries of uric acid and good precision, and results agreed with those by the uricase-catalase method of Kageyama (Clin Chim Acta 1971;31:421-6).
Yang, Xing-Xin; Zhang, Xiao-Xia; Chang, Rui-Miao; Wang, Yan-Wei; Li, Xiao-Ni
2011-01-01
A simple and reliable high performance liquid chromatography (HPLC) method has been developed for the simultaneous quantification of five major bioactive components in ‘Shu-Jin-Zhi-Tong’ capsules (SJZTC), for the purposes of quality control of this commonly prescribed traditional Chinese medicine. Under the optimum conditions, excellent separation was achieved, and the assay was fully validated in terms of linearity, precision, repeatability, stability and accuracy. The validated method was applied successfully to the determination of the five compounds in SJZTC samples from different production batches. The HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of SJZTC. PMID:29403711
Marwah, Ashok; Marwah, Padma; Lardy, Henry
2005-09-25
17alpha-Methyltestosterone (MT) is used to manipulate the gender of a variety of fish species. A high performance liquid chromatography (HPLC) internal standard method for the determination of 17alpha-methyltestosterone in fish feed using 3beta-methoxy-17beta-hydroxyandrost-5-en-7-one as internal standard (IS) has been developed. The method has been validated for the quantitation of MT in fish feed using 245 nm UV absorbance as the parent wavelength and 255 nm as a qualifier wavelength. The method was validated in the concentration range of 15.0-120 mg/kg of 17alpha-methyltestosterone in fish feed. Method was also found to be suitable for other feeds.
Hegde, Satisha; Hegde, Harsha Vasudev; Jalalpure, Sunil Satyappa; Peram, Malleswara Rao; Pai, Sandeep Ramachandra; Roy, Subarna
2017-01-01
Saraca asoca (Roxb.) De Wilde (Ashoka) is a highly valued endangered medicinal tree species from Western Ghats of India. Besides treating cardiac and circulatory problems, S. asoca provides immense relief in gynecological disorders. Higher price and demand, in contrast to the smaller population size of the plant, have motivated adulteration with other plants such as Polyalthia longifolia (Sonnerat) Thwaites. The fundamental concerns in quality control of S. asoca arise due to its part of medicinal value (Bark) and the chemical composition. Phytochemical fingerprinting with proper selection of analytical markers is a promising method in addressing quality control issues. In the present study, high-performance liquid chromatography of phenolic compounds (gallic acid, catechin, and epicatechin) coupled to multivariate analysis was used. Five samples each of S. asoca, P. longifolia from two localities alongside five commercial market samples showed evidence of adulteration. Subsequently, multivariate hierarchical cluster analysis and principal component analysis was established to discriminate the adulterants of S. asoca. The proposed method ascertains identification of S. asoca from its putative adulterant P. longifolia and commercial market samples. The data generated may also serve as baseline data to form a quality standard for pharmacopoeias. SUMMARY Simultaneous quantification of gallic acid, catechin, epicatechin from Saraca asoca by high-performance liquid chromatographyDetection of S. asoca from adulterant and commercial samplesUse of analytical method along with a statistical tool for addressing quality issues. Abbreviations used: HPLC: High Performance Liquid Chromatography; RP-HPLC: Reverse Phase High Performance Liquid Chromatography; CAT: Catechin; EPI: Epicatechin; GA: Gallic acid; PCA: Principal Component Analysis. PMID:28808391
Behbahani, Mohammad; Najafi, Fatemeh; Bagheri, Saman; Bojdi, Majid Kalate; Hassanlou, Parmoon Ghareh; Bagheri, Akbar
2014-04-01
A simple, rapid, and efficient sample pretreatment technique, based on solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME), followed by high performance liquid chromatography (HPLC) has been developed for simultaneous preconcentration and trace detection of 2,4-dichlorophenoxyacetic acid (2,4-D) and 2-methyl-4-chlorophenoxyacetic acid (MCPA) in water and urine samples. Some parameters such as acidity of solution, the amount of salt, type, and volume of extraction solvents, type of disperser/de-emulsifier solvent, and its volume were investigated and optimized. Under optimum extraction conditions, the limits of detections (LODs) of this method for MCPA and 2,4-D were 0.2 and 0.6 μg L(-1) (based on 3S(b)/m) in water and 0.4 and 1.6 μg L(-1) in urine, respectively. Furthermore, dynamic linear range of this method for MCPA and 2,4-D was 1-300 and 2-400 μg L(-1), repectively. Finally, the applicability of the proposed method was evaluated by extraction and determination of the herbicides in urine and different water samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Derenzo, Stephen E.; Moses, William W.
An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method ofmore » liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.« less
High Performance Liquid Chromatography Experiments to Undergraduate Laboratories
ERIC Educational Resources Information Center
Kissinger, Peter T.; And Others
1977-01-01
Reviews the principles of liquid chromatography with electrochemical detection (LCEC), an analytical technique that incorporates the advantages of both liquids chromatography and electrochemistry. Also suggests laboratory experiments using this technique. (MLH)
Chen, Kai; Lynen, Frédéric; De Beer, Maarten; Hitzel, Laure; Ferguson, Paul; Hanna-Brown, Melissa; Sandra, Pat
2010-11-12
Stationary phase optimized selectivity liquid chromatography (SOSLC) is a promising technique to optimize the selectivity of a given separation by using a combination of different stationary phases. Previous work has shown that SOSLC offers excellent possibilities for method development, especially after the recent modification towards linear gradient SOSLC. The present work is aimed at developing and extending the SOSLC approach towards selectivity optimization and method development for green chromatography. Contrary to current LC practices, a green mobile phase (water/ethanol/formic acid) is hereby preselected and the composition of the stationary phase is optimized under a given gradient profile to obtain baseline resolution of all target solutes in the shortest possible analysis time. With the algorithm adapted to the high viscosity property of ethanol, the principle is illustrated with a fast, full baseline resolution for a randomly selected mixture composed of sulphonamides, xanthine alkaloids and steroids. Copyright © 2010 Elsevier B.V. All rights reserved.
Sauveur, C; Baune, A; Vergnes, N; Jeanniot, J P
1989-01-01
A selective and sensitive method for the determination of fenspiride in biological fluids is described. The method involves liquid-liquid extraction followed by separation on a reversed-phase column with electrochemical detection for low levels of the drug in plasma (less than or equal to 100 ng ml-1) or UV absorption for higher concentrations in plasma or urine. The method is suitable for pharmacokinetic analyses and drug monitoring studies.
1980-10-16
mixed culture with Streptococcus S mutans , Streptococcus singuis Staphylococcus aureus,*and Escheric ia coi 1 - sA -DoWed n o quaI It atfI ve -c nah...of both S. mutans and S. scnguis. I 4 |I KEY WORDS: Fatty Acids . High Performance Liquid Chromatography Mixed Bacterial Cultures Streptococcus sal...AND METHODS Streptococcus mutans (ATCC 25175), Streptococcus sanguis (ATCC 10557), Staphylococcus aureus (ATCC 25923) and Escherichia coli (ATCC 25922
A Highly Sensitive Method for Quantitative Determination of Abscisic Acid 1
Michler, Charles H.; Lineberger, R. Daniel; Chism, Grady W.
1986-01-01
An abscisic acid derivative was formed by reaction with pentafluorobenzyl bromide which allowed highly sensitive detection by gas-liquid chromatography with electron capture detection. In comparison to the methyl ester derivative, the pentafluorobenzyl derivative of abscisic acid was four times more sensitive to electron capture detection and was stable at room temperature in the presence of ultraviolet light. Derivatization was rapid and the molecular weight of the new compound was confirmed by gas-liquid chromatography-mass spectrometry. PMID:16665076
Osborne, D J; Peters, B J; Meade, C J
1983-11-01
The following high performance liquid chromatography system was found suitable for separating most lipoxygenase metabolites of arachidonic acid: Techsphere 5-C18 column, eluting solvent methanol:water:acetic acid (65:35:0.06 v/v), pH 5.3. Comparisons with other packing materials and solvent systems are described. The method could be used to identify lipoxygenase products released from mouse macrophage cells stimulated with gamma-hexachlorocyclohexane. Detection limits between 1 and 10 ng were obtained.
Hydrocarbon group type determination in jet fuels by high performance liquid chromatography
NASA Technical Reports Server (NTRS)
Antoine, A. C.
1977-01-01
Thirty-two jet and diesel fuel samples of varying chemical composition and physical properties were prepared from oil shale and coal syncrudes. Hydrocarbon types in these samples were determined by a fluorescent indicator adsorption analysis, and the results from three laboratories are presented and compared. Two methods of rapid high performance liquid chromatography were used to analyze some of the samples, and these results are also presented and compared. Two samples of petroleum-based Jet A fuel are similarly analyzed.
Chan, W; Gerhardt, G C; Salisbury, C D
1994-01-01
A method for the simultaneous determination of tylosin and tilmicosin residues in animal tissues is reported. Solid-phase extraction columns are used to isolate the drugs from tissue extracts. Determination is accomplished by reversed-phase liquid chromatography with UV detection at 287 nm. Mean recoveries from spiked tissues were 79.9% (coefficient of variation [CV], 8.1%) for tylosin and 92.6% (CV, 8.7%) for tilmicosin. Detection limits for tylosin and tilmicosin were 0.020 and 0.010 ppm, respectively.
Quality Analysis of Chlorogenic Acid and Hyperoside in Crataegi fructus
Weon, Jin Bae; Jung, Youn Sik; Ma, Choong Je
2016-01-01
Background: Crataegi fructus is a herbal medicine for strong stomach, sterilization, and alcohol detoxification. Chlorogenic acid and hyperoside are the major compounds in Crataegi fructus. Objective: In this study, we established novel high-performance liquid chromatography (HPLC)-diode array detection analysis method of chlorogenic acid and hyperoside for quality control of Crataegi fructus. Materials and Methods: HPLC analysis was achieved on a reverse-phase C18 column (5 μm, 4.6 mm × 250 mm) using water and acetonitrile as mobile phase with gradient system. The method was validated for linearity, precision, and accuracy. About 31 batches of Crataegi fructus samples collected from Korea and China were analyzed by using HPLC fingerprint of developed HPLC method. Then, the contents of chlorogenic acid and hyperoside were compared for quality evaluation of Crataegi fructus. Results: The results have shown that the average contents (w/w %) of chlorogenic acid and hyperoside in Crataegi fructus collected from Korea were 0.0438% and 0.0416%, respectively, and the average contents (w/w %) of 0.0399% and 0.0325%, respectively. Conclusion: In conclusion, established HPLC analysis method was stable and could provide efficient quality evaluation for monitoring of commercial Crataegi fructus. SUMMARY Quantitative analysis method of chlorogenic acid and hyperoside in Crataegi fructus is developed by high.performance liquid chromatography.(HPLC).diode array detectionEstablished HPLC analysis method is validated with linearity, precision, and accuracyThe developed method was successfully applied for quantitative analysis of Crataegi fructus sample collected from Korea and China. Abbreviations used: HPLC: High-performance liquid chromatography, GC: Gas chromatography, MS: Mass spectrometer, LOD: Limits of detection, LOQ: Limits of quantification, RSD: Relative standard deviation, RRT: Relative retention time, RPA: Relation peak area. PMID:27076744
Use of high pressure liquid chromatography in the study of liquid lubricant oxidation
NASA Technical Reports Server (NTRS)
Morales, W.
1982-01-01
The general principles of classical liquid chromatography and high-pressure liquid chromatography (HPLC) are reviewed, and their advantages and disadvantages are compared. Several chromatographic techniques are reviewed, and the analysis of a C-ether liquid lubricant by each technique is illustrated. An analysis by size exclusion chromatography of an ester lubricant, which had been degraded using a micro-oxidation apparatus, is illustrated to show how HPLC can be used in the study of high-temperature lubricant degradation.
Wankhede, S. B.; Raka, K. C.; Wadkar, S. B.; Chitlange, S. S.
2010-01-01
Two UV-spectrophotometric and one reverse phase high performance liquid chromatography methods have been developed for the simultaneous estimation of amlodipine besilate, losartan potassium and hydrochlorothiazide in tablet dosage form. The first UV spectrophotometric method was a determination using the simultaneous equation method at 236.5, 254 and 271 nm over the concentration range 5-25, 10-50 and 5-25 μg/ml for amlodipine besilate, losartan potassium and hydrochlorothiazide, respectively. The second UV method was a determination using the area under curve method at 231.5-241.5, 249-259 and 266-276 nm over the concentration range of 5-25, 5-25 and 10-50 μg/ml for amlodipine besilate, hydrochlorothiazide and losartan potassium, respectively. In reverse phase high performance liquid chromatography analysis is carried out using 0.025 M phosphate buffer (pH 3.7):acetonitrile (57:43 v/v) as the mobile phase and Kromasil C18 (4.6 mm i.d×250 mm) column as stationery phase with detection wavelength of 232 nm linearity was obtained in the concentration range of 2-14, 20-140 and 5-40 μg/ml for amlodipine besilate, losartan potassium and hydrochlorothiazide, respectively. Both UV-spectrophotometric and reverse phase high performance liquid chromatography methods were statistically validated and can be used for analysis of combined dose tablet formulation containing amlodipine besilate, losartan potassium and hydrochlorothiazide. PMID:20582208
Paired-ion chromatography and high performance liquid chromatography of labetalol in feeds.
Townley, E R; Ross, B
1980-11-01
A high performance liquid chromatographic (HPLC) method using reverse phase paired-ion chromatography and ultraviolet detection at 280 nm has been developed to determine labetalol, an alpha and beta adrenoceptor blocking agent, in Purina No. 5001 rodent chow. The method is simple and rapid, and demonstrates a separation technique applicable to other acidic and basic drugs. It requires only extraction of the drug with methanol--water--acetic acid (66 + 33 + 1) and separation of insoluble material by filtration before HPLC. Labetalol, is chromatographically separated from soluble feed components by means of a microBondapak C18 column and methanol--water--acetic acid (66 + 33 + 1) mobile phase, 0.005M with respect to sodium dioctylsulfosuccinate paired-ion reagent. Average recovery is 98.7% with a relative standard deviation of +/- 2.3% for the equipment described.
Pires, Adriana Elias; Honda, Neli Kiko; Cardoso, Cláudia Andréa Lima
2004-10-29
A method for sample preparation and analysis by high performance liquid chromatography with UV detection (HPLC-UV) has been developed for routine analysis of psoralen and bergapten, photosensitizing compounds, in oral solutions of phytomedicines employed in Brazil for some illnesses. The linearity, accuracy, the inter- and intra-day precision of the procedure were evaluated. Calibration curves for psoralen and bergapten were linear in the range of 1.0-600.0 microg ml(-1) and 1.0-400.0 microg ml(-1) respectively. The recoveries of the psoralens in the oral solutions analysed were 94.43-99.97%. The percentage coefficient of variation (CV) of the quantitative analysis of the psoralens in the products analysis was within 5%. In inter-equipment study was employed gas chromatography-flame ionization (CG-FID) detection.
Douša, Michal; Pivoňková, Veronika; Sýkora, David
2016-08-01
A rapid procedure for the determination of memantine based on hydrophilic interaction chromatography with fluorescence detection was developed. Fluorescence detection after postcolumn derivatization with o-phtaldialdehyde/2-mercaptoethanol was performed at excitation and emission wavelengths of 345 and 450 nm, respectively. The postcolumn reaction conditions such as reaction temperature, derivatization reagent flow rate, and reagents concentration were studied due to steric hindrance of amino group of memantine. The derivatization reaction was applied for the hydrophilic interaction liquid chromatography method which was based on Cogent Silica-C stationary phase with a mobile phase consisting of a mixture of 10 mmol/L citric acid and 10 mmol/L o-phosphoric acid (pH 6.0) with acetonitrile using an isocratic composition of 2:8 v/v. The benefit of the reported approach consists in a simple sample pretreatment and a quick and sensitive hydrophilic interaction chromatography method. The developed method was validated in terms of linearity, accuracy, precision, and selectivity according to the International Conference on Harmonisation guidelines. The developed method was successfully applied for the analysis of commercial memantine tablets. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Aldeek, Fadi; Hsieh, Kevin C; Ugochukwu, Obiadada N; Gerard, Ghislain; Hammack, Walter
2018-05-23
We developed and validated a method for the extraction, identification, and quantitation of four nitrofuran metabolites, 3-amino-2-oxazolidinone (AOZ), 3-amino-5-morpholinomethyl-2-oxazolidinone (AMOZ), semicarbazide (SC), and 1-aminohydantoin (AHD), as well as chloramphenicol and florfenicol in a variety of seafood commodities. Samples were extracted by liquid-liquid extraction techniques, analyzed by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), and quantitated using commercially sourced, derivatized nitrofuran metabolites, with their isotopically labeled internal standards in-solvent. We obtained recoveries of 90-100% at various fortification levels. The limit of detection (LOD) was set at 0.25 ng/g for AMOZ and AOZ, 1 ng/g for AHD and SC, and 0.1 ng/g for the phenicols. Various extraction methods, standard stability, derivatization efficiency, and improvements to conventional quantitation techniques were also investigated. We successfully applied this method to the identification and quantitation of nitrofuran metabolites and phenicols in 102 imported seafood products. Our results revealed that four of the samples contained residues from banned veterinary drugs.
Zokaei, Maryam; Abedi, Abdol-Samad; Kamankesh, Marzieh; Shojaee-Aliababadi, Saeedeh; Mohammadi, Abdorreza
2017-11-01
In this research, for the first time, we successfully developed ultrasonic-assisted extraction and dispersive liquid-liquid microextraction combined with gas chromatography-mass spectrometry as a new, fast and highly sensitive method for determining of acrylamide in potato chips samples. Xanthydrol was used as a derivatization reagent and parameters affecting in the derivatization and microextraction steps were studied and optimized. Under optimum conditions, the calibration curves showed high levels of linearity (R 2 >0.9993) for acrylamide in the range of 2-500ngmL -1 . The relative standard deviation (RSD) for the seven analyses was 6.8%. The limit of detection (LOD) and limit of quantification (LOQ) were 0.6ngg -1 and 2ngg -1 , respectively. The UAE-DLLME-GC-MS method demonstrated high sensitivity, good linearity, recovery, and enrichment factor. The performance of the new proposed method was evaluated for the determination of acrylamide in various types of chips samples and satisfactory results were obtained. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hoff, Rodrigo Barcellos; Pizzolato, Tânia Mara; Peralba, Maria do Carmo Ruaro; Díaz-Cruz, M Silvia; Barceló, Damià
2015-03-01
Sulfonamides are widely used in human and veterinary medicine. The presence of sulfonamides residues in food is an issue of great concern. Throughout the present work, a method for the targeted analysis of 16 sulfonamides and metabolites residue in liver of several species has been developed and validated. Extraction and clean-up has been statistically optimized using central composite design experiments. Two extraction methods have been developed, validated and compared: i) pressurized liquid extraction, in which samples were defatted with hexane and subsequently extracted with acetonitrile and ii) ultrasound-assisted extraction with acetonitrile and further liquid-liquid extraction with hexane. Extracts have been analyzed by liquid chromatography-quadrupole linear ion trap-tandem mass spectrometry. Validation procedure has been based on the Commission Decision 2002/657/EC and included the assessment of parameters such as decision limit (CCα), detection capability (CCβ), sensitivity, selectivity, accuracy and precision. Method׳s performance has been satisfactory, with CCα values within the range of 111.2-161.4 µg kg(-1), limits of detection of 10 µg kg(-1) and accuracy values around 100% for all compounds. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Chuanxian; Qu, Li; Liu, Xia; Zhao, Chaomin; Zhao, Fengjuan; Huang, Fuzhen; Zhu, Zhenou; Han, Chao
2017-02-01
An analytical method has been developed for the detection of a metabolite of nifursol, 3,5-dinitrosalicylic acid hydrazide, in foodstuffs of animal origin (chicken liver, pork liver, lobster, shrimp, eel, sausage, and honey). The method combines liquid chromatography and tandem mass spectrometry with liquid-liquid extraction. Samples were hydrolyzed with hydrochloric acid and derivatized with 2-nitrobenzaldehyde at 37°C for 16 h. The solutions of derivatives were adjusted to pH 7.0-7.5, and the metabolite was extracted with ethyl acetate. 3,5-Dinitrosalicylic acid hydrazide determination was performed in the negative electrospray ionization method. Both isotope-labeled internal standard and matrix-matched calibration solutions were used to correct the matrix effects. Limits of quantification were 0.5 μg/kg for all samples. The average recoveries, measured at three concentration levels (0.5, 2.0, and 10 μg/kg) were in the range of 75.8-108.4% with relative standard deviations below 9.8%. The developed method exhibits a high sensitivity and selectivity for the routine determination and confirmation of the presence of a metabolite of nifursol in foodstuffs of animal origin. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Faraji, Mohammad; Hamdamali, Mohammadrezza; Aryanasab, Fezzeh; Shabanian, Meisam
2018-07-13
In this research, an ultrasonic-assisted extraction followed by 2-naphthalenthiol derivatization and dispersive liquid-liquid microextraction of acrylamide (AA) was developed as simple and sensitive sample preparation method for AA in bread and biscuit samples using high performance liquid chromatography. Influence of derivatization and microextraction parameters were evaluated and optimized. Results showed that the derivatization of AA leads to improve its hydrophobicity and chromatographic behavior. Under optimum conditions of derivatization and microextraction, the method yielded a linear calibration curve ranging from 10 to 1000 μg L -1 with a determination coefficient (R 2 ) of 0.9987. Limit of detection (LOD) and limit of quantification (LOQ) were 3.0 and 9.0 μg L -1 , respectively. Intra-day (n = 6) and inter-day (n = 3) precisions based on relative standard deviation percent (RSD%) for extraction and determination of AA at 50 and 500 μg L -1 levels were less than 9.0%. Finally, the performance of proposed method was investigated for determination of AA in some bread and biscuit samples, and satisfactory results were obtained (relative recovery ≥ 90%). Copyright © 2018. Published by Elsevier B.V.
Zhang, Jiaheng; Gao, Haixiang; Peng, Bing; Li, Yubo; Li, Songqing; Zhou, Zhiqiang
2012-01-15
A novel pretreatment method termed ultrasound-assisted dispersive liquid-liquid microextraction (UADLLME) coupled with high-performance liquid chromatography-ultraviolet detector (HPLC-UV) was applied for the detection of four synthesized metabolites of mequindox in pig urine samples. A total volume of 200 μL of methanol (dispersant) and 60 μL of 1,1,2,2-tetrachloroethane (extract) were injected into 5.0 mL of urine sample and then emulsified by ultrasound treatment for 4 min to form a cloudy solution. The effect of several factors on the recovery of each metabolite was investigated by a fitting derivation method for the first time. Under optimum conditions, the method yields a linear calibration curve in the concentration range from 0.5 to 500 μg/L and a limit of detection (LOD) of 0.16-0.28 μg/L for target analytes. The recoveries ranged from 72.0% to 91.3% with a relative standard deviation (RSD) of less than 5.2%. The enrichment factors for the four compounds ranged from 75 to 95. Two pig urine samples were successfully analyzed using the proposed method. Copyright © 2011 Elsevier B.V. All rights reserved.
Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Campos Motta, Tanara Magalhães; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara
2015-11-01
A fast and simple method for residue analysis of the antibiotics classes of macrolides (erythromycin, azithromycin, tylosin, tilmicosin and spiramycin) and lincosamides (lincomycin and clindamycin) was developed and validated for cattle, swine and chicken muscle and for bovine milk. Sample preparation consists in a liquid-liquid extraction (LLE) with acetonitrile, followed by liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-ESI-MS/MS), without the need of any additional clean-up steps. Chromatographic separation was achieved using a C18 column and a mobile phase composed by acidified acetonitrile and water. The method was fully validated according the criteria of the Commission Decision 2002/657/EC. Validation parameters such as limit of detection, limit of quantification, linearity, accuracy, repeatability, specificity, reproducibility, decision limit (CCα) and detection capability (CCβ) were evaluated. All calculated values met the established criteria. Reproducibility values, expressed as coefficient of variation, were all lower than 19.1%. Recoveries range from 60% to 107%. Limits of detection were from 5 to 25 µg kg(-1).The present method is able to be applied in routine analysis, with adequate time of analysis, low cost and a simple sample preparation protocol. Copyright © 2015. Published by Elsevier B.V.
Doshi, Gaurav Mahesh; Une, Hemant Devidas
2016-01-01
Objective: In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. Materials and Methods: In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. Results: HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. Conclusion: The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. SUMMARY Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida PMID:26941534
Kazarian, Artaches A; Nesterenko, Pavel N; Soisungnoen, Phimpha; Burakham, Rodjana; Srijaranai, Supalax; Paull, Brett
2014-08-01
Liquid chromatographic assays were developed using a mixed-mode column coupled in sequence with a hydrophilic interaction liquid chromatography column to allow the simultaneous comprehensive analysis of inorganic/organic anions and cations, active pharmaceutical ingredients, and excipients (carbohydrates). The approach utilized dual sample injection and valve-mediated column switching and was based upon a single high-performance liquid chromatography gradient pump. The separation consisted of three distinct sequential separation mechanisms, namely, (i) ion-exchange, (ii) mixed-mode interactions under an applied dual gradient (reversed-phase/ion-exchange), and (iii) hydrophilic interaction chromatography. Upon first injection, the Scherzo SS C18 column (Imtakt) provided resolution of inorganic anions and cations under isocratic conditions, followed by a dual organic/salt gradient to elute active pharmaceutical ingredients and their respective organic counterions and potential degradants. At the top of the mixed-mode gradient (high acetonitrile content), the mobile phase flow was switched to a preconditioned hydrophilic interaction liquid chromatography column, and the standard/sample was reinjected for the separation of hydrophilic carbohydrates, some of which are commonly known excipients in drug formulations. The approach afforded reproducible separation and resolution of up to 23 chemically diverse solutes in a single run. The method was applied to investigate the composition of commercial cough syrups (Robitussin®), allowing resolution and determination of inorganic ions, active pharmaceutical ingredients, excipients, and numerous well-resolved unknown peaks. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yang, Guang; Sun, Qiushi; Hu, Zhiyan; Liu, Hua; Zhou, Tingting; Fan, Guorong
2015-10-01
In this study, an accelerated solvent extraction dispersive liquid-liquid microextraction coupled with gas chromatography and mass spectrometry was established and employed for the extraction, concentration and analysis of essential oil constituents from Ligusticum chuanxiong Hort. Response surface methodology was performed to optimize the key parameters in accelerated solvent extraction on the extraction efficiency, and key parameters in dispersive liquid-liquid microextraction were discussed as well. Two representative constituents in Ligusticum chuanxiong Hort, (Z)-ligustilide and n-butylphthalide, were quantitatively analyzed. It was shown that the qualitative result of the accelerated solvent extraction dispersive liquid-liquid microextraction approach was in good agreement with that of hydro-distillation, whereas the proposed approach took far less extraction time (30 min), consumed less plant material (usually <1 g, 0.01 g for this study) and solvent (<20 mL) than the conventional system. To sum up, the proposed method could be recommended as a new approach in the extraction and analysis of essential oil. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Protein separations using enhanced-fluidity liquid chromatography.
Bennett, Raffeal; Olesik, Susan V
2017-11-10
Enhanced-fluidity liquid chromatography (EFLC) methods using methanol/H 2 O/CO 2 and hydrophilic interaction liquid chromatography (HILIC) were explored for the separation of proteins and peptides. EFLC is a separation mode that uses a mobile phase made of conventional solvents combined with liquid carbon dioxide (CO 2 ) in subcritical conditions. The addition of liquid CO 2 enhances diffusivity and decreases viscosity while maintaining mixture polarity, which typically results in reduced time of analysis. TFA additive and elevated temperature were leveraged as key factors in the separation of a 13-analyte intact protein mixture in under 5min. Under these conditions EFLC showed modest improvement in terms of peak asymmetry and analysis time over the competing ACN/H 2 O separation. Protein analytes detected by electrospray ionization - quadrupole time of flight, were shown to be unaffected by the addition of CO 2 in the mobile phase. Herein, the feasibility of separating hydrophilic proteins up to 80kDa (with transferrin) is demonstrated for CO 2 -containing mobile phases. Copyright © 2017 Elsevier B.V. All rights reserved.
Comprehensive Urine Drug Screen by Gas Chromatography/Mass Spectrometry (GC/MS).
Ramoo, Bheemraj; Funke, Melissa; Frazee, Clint; Garg, Uttam
2016-01-01
Drug screening is an essential component of clinical toxicology laboratory service. Some laboratories use only automated chemistry analyzers for limited screening of drugs of abuse and few other drugs. Other laboratories use a combination of various techniques such as immunoassays, colorimetric tests, and mass spectrometry to provide more detailed comprehensive drug screening. Mass spectrometry, gas or liquid, can screen for hundreds of drugs and is often considered the gold standard for comprehensive drug screening. We describe an efficient and rapid gas chromatography/mass spectrometry (GC/MS) method for comprehensive drug screening in urine which utilizes a liquid-liquid extraction, sample concentration, and analysis by GC/MS.
da Costa, José Luiz; da Matta Chasin, Alice Aparecida
2004-11-05
This paper describes the development and validation of analytical methodology for the determination of the use of MDMA, MDEA and MDA in urine. After a simple liquid extraction, the analyses were carried out on a high performance liquid chromatography (HPLC) in an octadecyl column, with fluorescence detection. The mobile phase using a sodium dodecyl sulfate ion-pairing reagent allows good separation and efficiency. The method showed good linearity and precision. Recovery was between 85 and 102% and detection limits were 10, 15 and 20 ng/ml for MDA, MDMA and MDEA, respectively. No interfering substances were detected with fluorescence detection.
The Hildebrand solubility parameters of ionic liquids-part 2.
Marciniak, Andrzej
2011-01-01
The Hildebrand solubility parameters have been calculated for eight ionic liquids. Retention data from the inverse gas chromatography measurements of the activity coefficients at infinite dilution were used for the calculation. From the solubility parameters, the enthalpies of vaporization of ionic liquids were estimated. Results are compared with solubility parameters estimated by different methods.
Magiera, Sylwia; Kwietniowska, Ewelina
2016-11-15
In this study, an easy, simple and efficient method for the determination of naringenin enantiomers in fruit juices after salting-out-assisted liquid-liquid extraction (SALLE) and high-performance liquid chromatography (HPLC) with diode-array detection (DAD) was developed. The sample treatment is based on the use of water-miscible acetonitrile as the extractant and acetonitrile phase separation under high-salt conditions. After extraction, juice samples were incubated with hydrochloric acid in order to achieve hydrolysis of naringin to naringenin. The hydrolysis parameters were optimized by using a half-fraction factorial central composite design (CCD). After sample preparation, chromatographic separation was obtained on a Chiralcel® OJ-RH column using the mobile phase consisting of 10mM aqueous ammonium acetate:methanol:acetonitrile (50:30:20; v/v/v) with detection at 288nm. The average recovery of the analyzed compounds ranged from 85.6 to 97.1%. The proposed method was satisfactorily used for the determination of naringenin enantiomers in various fruit juices samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Arbeláez, Paula; Granados, Judith; Borrull, Francesc; Marcé, Rosa Maria; Pocurull, Eva
2014-12-01
This paper describes a method for the determination of eight sedative hypnotics (benzodiazepines and barbiturates) in sewage sludge using pressurized liquid extraction and liquid chromatography with tandem mass spectrometry. Pressurized liquid extraction operating conditions were optimized and maximum recoveries were reached using methanol under the following operational conditions: 100ºC, 1500 psi, extraction time of 5 min, one extraction cycle, flush volume of 60% and purge time of 120 s. Pressurized liquid extraction recoveries were higher than 88% for all the compounds except for carbamazepine (55%). The repeatability and reproducibility between days, expressed as relative standard deviation (n = 5), were lower than 6 and 10%, respectively. The detection limits for all compounds were lower than 12.5 μg/kg of dry weight. The method was applied to determine benzodiazepines and barbiturates in sewage sludge from urban sewage treatment plants, and carbamazepine showed the highest concentration (7.9-18.9 μg/kg dry weight). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hamed, Ahmed M; Arroyo-Manzanares, Natalia; García-Campaña, Ana M; Gámiz-Gracia, Laura
2017-11-01
Vegetable milks are considered as functional foods due to their physiological benefits. Although the consumption of these products has significantly increased, they have received little attention in legislation with regard to contaminants. However, they may contain mycotoxins resulting from the use of contaminated raw materials. In this work, ultra-high-performance liquid chromatography tandem mass spectrometry has been proposed for the determination of the most relevant Fusarium toxins (fumonisin B 1 and B 2 , HT-2 and T-2 toxins, zearalenone, deoxynivalenol and fusarenon-X) in different functional beverages based on cereals, legumes and seeds. Sample treatment consisted of a simple salting-out-assisted liquid-liquid extraction with no further clean-up. The method provided limits of quantification between 3.2 and 57.7 µg L -1 , recoveries above 80% and precision with RSD lower than 12%. The method was also applied for studying the occurrence of these mycotoxins in market samples of vegetable functional beverages and deoxynivalenol was found in three oat-based commercial drinks.
He, Yongrui; Zhao, Xian-En; Wang, Renjun; Wei, Na; Sun, Jing; Dang, Jun; Chen, Guang; Liu, Zhiqiang; Zhu, Shuyun; You, Jinmao
2016-11-02
A simple, rapid, sensitive, selective, and environmentally friendly method, based on in situ derivatization ultrasound-assisted dispersive liquid-liquid microextraction (in situ DUADLLME) coupled with ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) using multiple reaction monitoring (MRM) mode has been developed for the simultaneous determination of food-related biogenic amines and amino acids. A new mass-spectrometry-sensitive derivatization reagent 4'-carbonyl chloride rosamine (CCR) was designed, synthesized, and first reported. Parameters and conditions of in situ DUADLLME and UHPLC-MS/MS were optimized in detail. Under the optimized conditions, the in situ DUADLLME was completed speedily (within 1 min) with high derivatization efficiencies (≥98.5%). With the cleanup and concentration of microextraction step, good analytical performance was obtained for the analytes. The results showed that this method was accurate and practical for quantification of biogenic amines and amino acids in common food samples (red wine, beer, wine, cheese, sausage, and fish).
Liu, Shao-Ying; Huang, Xi-Hui; Wang, Xiao-Fang; Jin, Quan; Zhu, Guo-Nian
2014-05-01
This study developed an improved analytical method for the simultaneous quantification of 13 quinolones in cosmetics by ultra high performance liquid chromatography combined with ESI triple quadrupole MS/MS under the multiple reaction monitoring mode. The analytes were extracted and purified by using an SPE cartridge. The limits of quantification ranged from 0.03 to 3.02 μg/kg. The precision for determining the quinolones was <19.39%. The proposed method was successfully developed for the determination of quinolones in real cosmetic samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Xu, Jiao-Jiao; Zhou, Jian; Huang, Bai-Fen; Cai, Zeng-Xuan; Xu, Xiao-Min; Ren, Yi-Ping
2016-06-01
A simple and reliable method of ultra high performance liquid chromatography coupled with photo-diode array detection has been proposed for the simultaneous determination of deoxynivalenol and its acetylated derivatives in wheat flour and rice, especially focusing on the optimization of sample extraction, cleanup, and chromatographic separation conditions. Sample pretreatment consisted of a first step using a quick, easy, cheap, effective, rugged, and safe based extraction procedure and a subsequent cleanup step based on solid-phase extraction. The method was extensively validated in wheat flour and rice, obtaining satisfactory analytical performance with good linearity (R(2) ≥ 0.999), acceptable recoveries (80.0-104.4%), and repeatability (RSDs 1.3-10.7%). The limits of detection (21.7-57.4 μg/kg) and quantitation (72.3-191.4 μg/kg) for deoxynivalenols were lower than those usually permitted by various countries' legislation in these food matrices. The method was applied to 34 wheat and rice samples. The results were further compared with results of ultra high performance liquid chromatography with electrospray ionization tandem mass spectrometry. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Silva, Marisa; Rey, Verónica; Botana, Ana; Vasconcelos, Vitor; Botana, Luis
2015-01-01
Paralytic Shellfish Toxin blooms are common worldwide, which makes their monitoring crucial in the prevention of poisoning incidents. These toxins can be monitored by a variety of techniques, including mouse bioassay, receptor binding assay, and liquid chromatography with either mass spectrometric or pre- or post-column fluorescence detection. The post-column oxidation liquid chromatography with fluorescence detection method, used routinely in our laboratory, has been shown to be a reliable method for monitoring paralytic shellfish toxins in mussel, scallop, oyster and clam species. However, due to its high sensitivity to naturally fluorescent matrix interferences, when working with unconventional matrices, there may be problems in identifying toxins because of naturally fluorescent interferences that co-elute with the toxin peaks. This can lead to erroneous identification. In this study, in order to overcome this challenge in echinoderm and gastropod matrices, we optimized the conversion of Gonyautoxins 1 and 4 to Neosaxitoxin with 2-mercaptoethanol. We present a new and less time-consuming method with a good recovery (82.2%, RSD 1.1%, n = 3), requiring only a single reaction step. PMID:26729166
Zheng, Cao; Zhao, Jing; Bao, Peng; Gao, Jin; He, Jin
2011-06-24
A novel, simple and efficient dispersive liquid-liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) technique coupled with high-performance liquid chromatography with ultraviolet detection (HPLC-UV) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of triclosan and its degradation product 2,4-dichlorophenol in real water samples. The extraction solvent used in this work is of low density, low volatility, low toxicity and proper melting point around room temperature. The extractant droplets can be collected easily by solidifying it at a lower temperature. Parameters that affect the extraction efficiency, including type and volume of extraction solvent and dispersive solvent, salt effect, pH and extraction time, were investigated and optimized in a 5 mL sample system by HPLC-UV. Under the optimum conditions (extraction solvent: 12 μL of 1-dodecanol; dispersive solvent: 300 of μL acetonitrile; sample pH: 6.0; extraction time: 1 min), the limits of detection (LODs) of the pretreatment method combined with LC-MS/MS were in the range of 0.002-0.02 μg L(-1) which are lower than or comparable with other reported approaches applied to the determination of the same compounds. Wide linearities, good precisions and satisfactory relative recoveries were also obtained. The proposed technique was successfully applied to determine triclosan and 2,4-dichlorophenol in real water samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Wu, Yu-Tse; Wu, Ming-Tsang; Lin, Chia-Chun; Chien, Chao-Feng; Tsai, Tung-Hu
2012-01-01
The safety of herbal products is one of the major concerns for the modernization of traditional Chinese medicine, and pharmacokinetic data of medicinal herbs guide us to design the rational use of the herbal formula. This article reviews the advantages of the automated blood sampling (ABS) systems for pharmacokinetic studies. In addition, three commonly used sample preparative methods, protein precipitation, liquid-liquid extraction and solid-phase extraction, are introduced. Furthermore, the definition, causes and evaluation of matrix effects in liquid chromatography-mass spectrometry (LC/MS) analysis are demonstrated. Finally, we present our previous works as practical examples of the application of ABS systems and LC/MS for the pharmacokinetic studies of Chinese medicinal herbs.
76 FR 38033 - Cloquintocet-mexyl; Pesticide Tolerances
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-29
... enforcement methods are the High Performance Liquid Chromatography with Ultraviolet Detection (HPLC/UV) method REM 138.01 for determination of cloquintocet-mexyl (parent) and the HPLC/UV Method REM 138.10 for...
Vo Duy, S; Besteiro, S; Berry, L; Perigaud, C; Bressolle, F; Vial, H J; Lefebvre-Tournier, I
2012-08-20
Plasmodium falciparum is the causative agent of malaria, a deadly infectious disease for which treatments are scarce and drug-resistant parasites are now increasingly found. A comprehensive method of identifying and quantifying metabolites of this intracellular parasite could expand the arsenal of tools to understand its biology, and be used to develop new treatments against the disease. Here, we present two methods based on liquid chromatography tandem mass spectrometry for reliable measurement of water-soluble metabolites involved in phospholipid biosynthesis, as well as several other metabolites that reflect the metabolic status of the parasite including amino acids, carboxylic acids, energy-related carbohydrates, and nucleotides. A total of 35 compounds was quantified. In the first method, polar compounds were retained by hydrophilic interaction chromatography (amino column) and detected in negative mode using succinic acid-(13)C(4) and fluorovaline as internal standards. In the second method, separations were carried out using reverse phase (C18) ion-pair liquid chromatography, with heptafluorobutyric acid as a volatile ion pairing reagent in positive detection mode, using d(9)-choline and 4-aminobutanol as internal standards. Standard curves were performed in P. falciparum-infected and uninfected red blood cells using standard addition method (r(2)>0.99). The intra- and inter-day accuracy and precision as well as the extraction recovery of each compound were determined. The lower limit of quantitation varied from 50pmol to 100fmol/3×10(7)cells. These methods were validated and successfully applied to determine intracellular concentrations of metabolites from uninfected host RBCs and isolated Plasmodium parasites. Copyright © 2012 Elsevier B.V. All rights reserved.
Wang, Jing; Zheng, Meizhu; Chen, Lina; Liu, Zhiqiang; Zhang, Yuchi; Liu, Chun-Ming; Liu, Shu
2016-11-01
Hydroxyl radicals are the most reactive free radical of human body, a strong contributor to tissue damage. In this study, liquid chromatography coupled to electrospray ionization mass spectrometry was applied to screen and identify hydroxyl radical scavengers from the total flavonoids of Ginkgo biloba leaves, and high-performance counter current chromatography was used to separate and isolate the active compounds. Furthermore, molecular devices were used to determine hydroxyl radical scavenging activities of the obtained hydroxyl radical scavengers and other flavonoids from G. biloba leaves. As a result, six compounds were screened as hydroxyl radical scavengers, but only three flavonoids, namely, rutin, cosmos glycosides and apigenin-7-O-Glu-4'-O-Rha, were isolated successfully from total flavonoids by high-performance counter current chromatography. The purities of the three obtained compounds were over 90%, respectively, as determined by liquid chromatography. Molecular devices with 96-well microplates evaluation indicated that the 50% scavenging concentration values of screened compounds were lower than that of other flavonoids, they performed greater hydroxyl radical scavenging activity, and the evaluation effects were consistent with the liquid chromatography with mass spectrometry screening results. Therefore, chromatography combined with molecular devices is a feasible and an efficient method for systematic screening, identification, isolation, and evaluation of bioactive components in mixture of botanical medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ERIC Educational Resources Information Center
Majors, Ronald E.; And Others
1984-01-01
Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…
Petrarca, Mateus Henrique; Ccanccapa-Cartagena, Alexander; Masiá, Ana; Godoy, Helena Teixeira; Picó, Yolanda
2017-05-12
A new selective and sensitive liquid chromatography triple quadrupole mass spectrometry method was developed for simultaneous analysis of natural pyrethrins and synthetic pyrethroids residues in baby food. In this study, two sample preparation methods based on ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) and salting-out assisted liquid-liquid extraction (SALLE) were optimized, and then, compared regarding the performance criteria. Appropriate linearity in solvent and matrix-based calibrations, and suitable recoveries (75-120%) and precision (RSD values≤16%) were achieved for selected analytes by any of the sample preparation procedures. Both methods provided the analytical selectivity required for the monitoring of the insecticides in fruit-, cereal- and milk-based baby foods. SALLE, recognized by cost-effectiveness, and simple and fast execution, provided a lower enrichment factor, consequently, higher limits of quantification (LOQs) were obtained. Some of them too high to meet the strict legislation regarding baby food. Nonetheless, the combination of ultrasound and DLLME also resulted in a high sample throughput and environmental-friendly method, whose LOQs were lower than the default maximum residue limit (MRL) of 10μgkg -1 set by European Community for baby foods. In the commercial baby foods analyzed, cyhalothrin and etofenprox were detected in different samples, demonstrating the suitability of proposed method for baby food control. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhang, Cheng; Cagliero, Cecilia; Pierson, Stephen A; Anderson, Jared L
2017-01-20
A simple and rapid ionic liquid (IL)-based in situ dispersive liquid-liquid microextraction (DLLME) method was developed and coupled to headspace gas chromatography (HS-GC) employing electron capture (ECD) and mass spectrometry (MS) detection for the analysis of polychlorinated biphenyls (PCBs) and acrylamide at trace levels from milk and coffee samples. The chemical structures of the halide-based ILs were tailored by introducing various functional groups to the cations to evaluate the effect of different structural features on the extraction efficiency of the target analytes. Extraction parameters including the molar ratio of IL to metathesis reagent and IL mass were optimized. The effects of HS oven temperature and the HS sample vial volume on the analyte response were also evaluated. The optimized in situ DLLME method exhibited good analytical precision, good linearity, and provided detection limits down to the low ppt level for PCBs and the low ppb level for acrylamide in aqueous samples. The matrix-compatibility of the developed method was also established by quantifying acrylamide in brewed coffee samples. This method is much simpler and faster compared to previously reported GC-MS methods using solid-phase microextraction (SPME) for the extraction/preconcentration of PCBs and acrylamide from complex food samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Werner, Stephen L.; Burkhardt, Mark R.; DeRusseau, Sabrina N.
1996-01-01
In accordance with the needs of the National Water-Quality Assessment Program (NAWQA), the U.S. Geological Survey has developed and implemented a graphitized carbon-based solid-phase extraction and high-performance liquid chromatographic analytical method. The method is used to determine 41 pesticides and pesticide metabolites that are not readily amenable to gas chromatography or other high-temperature analytical techniques. Pesticides are extracted from filtered environmental water samples using a 0.5-gram graphitized carbon-based solid-phase cartridge, eluted from the cartridge into two analytical fractions, and analyzed using high-performance liquid chromatography with photodiode-array detection. The upper concentration limit is 1.6 micrograms per liter (=B5g/L) for most compounds. Single-operator method detection limits in organic-free water samples ranged from 0.006 to 0.032 =B5g/L= Recoveries in organic-free water samples ranged from 37 to 88 percent. Recoveries in ground- and surface-water samples ranged from 29 to 94 percent. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time of 7 days.
Wysoczynski, Christina L.; Roemer, Sarah C.; Dostal, Vishantie; Barkley, Robert M.; Churchill, Mair E. A.; Malarkey, Christopher S.
2013-01-01
Obtaining quantities of highly pure duplex DNA is a bottleneck in the biophysical analysis of protein–DNA complexes. In traditional DNA purification methods, the individual cognate DNA strands are purified separately before annealing to form DNA duplexes. This approach works well for palindromic sequences, in which top and bottom strands are identical and duplex formation is typically complete. However, in cases where the DNA is non-palindromic, excess of single-stranded DNA must be removed through additional purification steps to prevent it from interfering in further experiments. Here we describe and apply a novel reversed-phase ion-pair liquid chromatography purification method for double-stranded DNA ranging in lengths from 17 to 51 bp. Both palindromic and non-palindromic DNA can be readily purified. This method has the unique ability to separate blunt double-stranded DNA from pre-attenuated (n-1, n-2, etc) synthesis products, and from DNA duplexes with single base pair overhangs. Additionally, palindromic DNA sequences with only minor differences in the central spacer sequence of the DNA can be separated, and the purified DNA is suitable for co-crystallization of protein–DNA complexes. Thus, double-stranded ion-pair liquid chromatography is a useful approach for duplex DNA purification for many applications. PMID:24013567
Yu, Huan; Tao, Yanfei; Chen, Dongmei; Wang, Yulian; Huang, Lingli; Peng, Dapeng; Dai, Menghong; Liu, Zhenli; Wang, Xu; Yuan, Zonghui
2011-09-01
The residues of sulfonamides (SAs) in the foods of animal origin are of the major concern because they are harmful to the consumer's health and could induce pathogens to develop resistance. Rapid and efficient determination methods are urgently in need. A quantitative high performance liquid chromatography method (HPLC) and a confirmative liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 18 sulfonamides such as sulfamidinum, sulfanilamide, sulfisomidine, sulfadiazine, sulfapyridine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethoxypyridazine, sulfamethoxydiazine, sulfisoxazole, sulfachloropyridazine, sulfamethoxazole, sulfamonomethoxine, sulfadoxine, sulfaclozine, sulfadimethoxine, sulfaquinoxaline in the muscles, livers and kidneys of swine, bovine and chicken were developed and validated. The sample preparation procedures included a pressurized liquid extraction (PLE) with acetonitrile conducted at elevated temperature (70°C) and pressure (1400 psi). After clean-up with hydrophilic-lipophilic balance cartridge, the extraction solution was concentrated and analyzed by HPLC and LC-MS/MS analysis. 18 SAs were separated by the HPLC with a Zorbax SB-Aq-C18 column and the mobile phase of methanol/acetonitrile/1% acetic acid with a gradient system. The wavelength of UV for the HPLC detection was set at 285 nm. The LC-MS/MS analysis was achieved with a Hypersil Golden column and the mobile phase of acetonitrile and 0.1% formic acid aqueous solution with two gradient systems. The Limits of detection (LOD) and the limits of quantitation (LOQ) were 3 μg/kg and 10 μg/kg, respectively, for both of the HPLC and LC-MS/MS. Linearity was obtained with an average coefficient of determination (R) higher than 0.9980 over a dynamic range from the LOQ value up to 5000 μg/kg. The recoveries of the methods range from 71.1% to 118.3% with the relative standard derivation less than 13%. The peaks of interest with no interferences were observed throughout the chromatographic run. The sample pretreatment provided efficient extraction and cleanup that enables a sensitive and rugged determination of 18 SAs, the obtained results revealed that PLE, in comparison with other sample preparation methods applied, has significantly higher efficacy for SAs isolation from animal tissues. Copyright © 2011 Elsevier B.V. All rights reserved.
Liu, Yong-Qiang; Yu, Hong
2016-08-01
Indirect ultraviolet detection was conducted in ultraviolet-absorption-agent-added mobile phase to complete the detection of the absence of ultraviolet absorption functional group in analytes. Compared with precolumn derivatization or postcolumn derivatization, this method can be widely used, has the advantages of simple operation and good linear relationship. Chromatographic separation of Li(+) , Na(+) , K(+) , and NH4 (+) was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid/organic solvent as the mobile phase, in which imidazolium ionic liquids acted as ultraviolet absorption reagent and eluting agent. The retention behaviors of four kinds of cations are discussed, and the mechanism of separation and detection are described. The main factors influencing the separation and detection were the background ultraviolet absorption reagent and the concentration of hydrogen ion in the ion chromatography-indirect ultraviolet detection. The successful separation and detection of Li(+) , Na(+) , K(+) , and NH4 (+) within 13 min was achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.02, 0.11, 0.30, and 0.06 mg/L, respectively. A new separation and analysis method of alkali metal ions and ammonium by ion chromatography with indirect ultraviolet detection method was developed, and the application range of ionic liquid was expanded. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hamelin, Elizabeth I.; Schulze, Nicholas D.; Shaner, Rebecca L.; Coleman, Rebecca M.; Lawrence, Richard J.; Crow, Brian S.; Jakubowski, E. M.; Johnson, Rudolph C.
2015-01-01
Although nerve agent use is prohibited, concerns remain for human exposure to nerve agents during decommissioning, research, and warfare. Exposure can be detected through the analysis of the hydrolysis products in urine as well as blood. An analytical method to detect exposure to five nerve agents, including VX, VR (Russian VX), GB (sarin), GD (soman) and GF (cyclosarin), through the analysis of the hydrolysis products, which are the primary metabolites, in serum has been developed and characterized. This method uses solid phase extraction coupled with high performance liquid chromatography for separation and isotopic dilution tandem mass spectrometry for detection. An uncommon buffer of ammonium fluoride was used to enhance ionization and improve sensitivity when coupled with hydrophilic interaction liquid chromatography resulting in detection limits from 0.3–0.5 ng/mL. The assessment of two quality control samples demonstrated high accuracy (101–105%) and high precision (5–8%) for the detection of these five nerve agent hydrolysis products in serum. PMID:24633507
Russo, Marina; Dugo, Paola; Marzocco, Stefania; Inferrera, Veronica; Mondello, Luigi
2015-12-01
Important objectives of a high-performance liquid chromatography preparative process are: purity of products isolated, yield, and throughput. The multidimensional preparative liquid chromatography method used in this work was developed mainly to increase the throughput; moreover purity and yield are increased thanks to the automated collection of the molecules based on the intensity of a signal generated from the mass spectrometer detector, in this way only a specific product can be targeted. This preparative system allowed, in few analyses both in the first and second dimensions, the isolation of eight pure compounds present at very different concentration in the original sample with high purity (>95%) and yield, which showed how the system is efficient and versatile. Pure molecules were used to validate the analytical method and to test the anti-inflammatory and antiproliferative potential of flavonoids. The contemporary presence, in bergamot juice, of all the flavonoids together increases the anti-inflammatory effect with respect to the single compound alone. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jiang, Hongliang; Li, Yinghe; Pelzer, Mary; Cannon, Michelle J; Randlett, Christopher; Junga, Heiko; Jiang, Xiangyu; Ji, Qin C
2008-05-30
A sensitive and selective bioanalytical assay was developed and validated for the determination of enantiomeric molindone in human plasma using high-performance liquid chromatography-tandem mass spectrometry along with supported liquid extraction procedures. The chiral separation was evaluated and optimized on macrocyclic antibiotic type chiral stationary phases (CSPs) based on teicoplanin aglycone (Chirobiotic TAG) in polar organic, polar ionic, and reversed-phase mode chromatography, respectively. Complete baseline separation was achieved on a Chirobiotic TAG column under isocratic condition in reversed-phase chromatography. The method validation was conducted using a Chirobiotic TAG column (100 mm x 2.1 mm) over the curve range 0.100-100 ng/ml for each molindone enantiomer using 0.0500 ml of plasma sample. The flow rate was 0.8 ml/min and the total run time was 9 min. Supported liquid extraction in a 96-well plate format was used for sample preparation. Parameters including recovery, matrix effect, linearity, sensitivity, specificity, carryover, precision, accuracy, dilution integrity, and stability were evaluated. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels were RSD
Zhang, Minmin; Zhao, Hengqiang; Zhao, Zhiguo; Yan, Huijiao; Lv, Ruimin; Cui, Li; Yuan, Jinpeng; Wang, Daijie; Geng, Yanling; Liu, Daicheng; Wang, Xiao
2016-06-01
We put forward an efficient strategy based on bioassay guidance for the rapid screening, identification, and purification of the neuraminidase inhibitors from traditional Chinese medicines, and apply to the discovery of anti-influenza components from Lithospermiun erythrorhizon Sieb.et Zucc. Ultrafiltration with high-performance liquid chromatography and electrospray ionization time-of-flight mass spectrometry was employed for the rapid screening and preliminarily identification of anti-influenza components from Zicao. Semipreparative high-performance liquid chromatography was used for the rapid separation and purification of the target compounds. NMR spectroscopy, mass spectrometry, and UV spectroscopy were used for further structural identification, and the activity of the compounds was verified by in vitro assay. Five compounds were found to have neuraminidase inhibitory activity by this method. Subsequently, the five compounds were separated by semipreparative high-performance liquid chromatography with the purity over 98% for all of them by high-performance liquid chromatography test. Combined with the NMR spectroscopy, mass spectrometry, and UV spectroscopy data, they were identified as alkannin, acetylalkannin, isobutyrylalkannin, β,β-dimethylacryloylalkannin and isovalerylalkannin. The in vitro assay showed that all five compounds had good neuraminidase inhibitory activities. These results suggested that the method is highly efficient, and it can provide platform and methodology supports for the rapid discovery of anti-influenza active ingredients from complex Chinese herbal medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tong, Shengqiang; Shen, Mangmang; Cheng, Dongping; Ito, Yoichiro; Yan, Jizhong
2014-01-01
This work concentrates on the separation mechanism and application of chiral ligand exchange high-speed countercurrent chromatography (HSCCC) in enantioseparations, and comparison with traditional chiral ligand exchange high performance liquid chromatography (HPLC). The enantioseparation of ten aromatic α-hydroxyl acids were performed by these two chromatographic methods. Results showed that five of the racemates were successfully enantioseparated by HSCCC while only three of the racemates could be enantioseparated by HPLC using a suitable chiral ligand mobile phase additive. For HSCCC, the two-phase solvent system was composed of butanol-water (1:1, v/v), to which N-n-dodecyl-L-proline was added in the organic phase as chiral ligand and cupric acetate was added in the aqueous phase as a transition metal ion. Various operation parameters in HSCCC were optimized by enantioselective liquid-liquid extraction. Based on the results of the present studies the separation mechanism for HSCCC was proposed. For HPLC, the optimized mobile phase composed of aqueous solution containing 6 mmol L−1 L-phenylalanine and 3 mmol L−1 cupric sulfate and methanol was used for enantioseparation. Among three ligands tested on a conventional reverse stationary phase column, only one was found to be effective. In the present studies HSCCC presented unique advantages due to its high versatility of two-phase solvent systems and it could be used as an alternative method for enantioseparations. PMID:25087742
Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun
2015-03-27
A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2015 Elsevier B.V. All rights reserved.
Godin, Jean-Philippe; McCullagh, James S O
2011-10-30
High-precision isotope analysis is recognized as an essential research tool in many fields of study. Until recently, continuous flow isotope ratio mass spectrometry (CF-IRMS) was available via an elemental analyzer or a gas chromatography inlet system for compound-specific analysis of light stable isotopes. In 2004, however, an interface that coupled liquid chromatography with IRMS (LC/IRMS) became commercially available for the first time. This brought the capability for new areas of application, in particular enabling compound-specific δ(13)C analysis of non-volatile, aqueous soluble, compounds from complex mixtures. The interface design brought with it several analytical constraints, however, in particular a lack of compatibility with certain types of chromatography as well as limited flow rates and mobile phase compositions. Routine LC/IRMS methods have, however, been established for measuring the δ(13)C isotopic ratios of underivatized individual compounds for application in archeology, nutrition and physiology, geochemistry, hydrology, soil science and food authenticity. Seven years after its introduction, we review the technical advances and constraints, methodological developments and new applications of liquid chromatography coupled to isotope ratio mass spectrometry. Copyright © 2011 John Wiley & Sons, Ltd.
Polymer Analysis by Liquid Chromatography/Electrospray Ionization Time-of-Flight Mass Spectrometry.
Nielen, M W; Buijtenhuijs, F A
1999-05-01
Hyphenation of liquid chromatography (LC) techniques with electrospray ionization (ESI) orthogonal acceleration time-of-flight (oa-TOF) mass spectrometry (MS) provides both MS-based structural information and LC-based quantitative data in polymer analysis. In one experimental setup, three different LC modes are interfaced with MS: size-exclusion chromatography (SEC/MS), gradient polymer elution chromatography (GPEC/MS), and liquid chromatography at the critical point of adsorption (LCCC/MS). In SEC/MS, both absolute mass calibration of the SEC column based on the polymer itself and determination of monomers and end groups from the mass spectra are achieved. GPEC/MS shows detailed chemical heterogeneity of the polymer and the chemical composition distribution within oligomer groups. In LCCC/MS, the retention behavior is primarily governed by chemical heterogeneities, such as different end group functionalities, and quantitative end group calculations can be easily made. The potential of these methods and the benefit of time-of-flight analyzers in polymer analysis are discussed using SEC/MS of a polydisperse poly(methyl methacrylate) sample, GPEC/MS of dipropoxylated bisphenol A/adipic acid polyester resin, LCCC/MS of alkylated poly(ethylene glycol), and LCCC/MS of terephthalic acid/neopentyl glycol polyester resin.
Analysis of Biomass Sugars Using a Novel HPLC Method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agblevor, F. A.; Hames, B. R.; Schell, D.
The precise quantitative analysis of biomass sugars is a very important step in the conversion of biomass feedstocks to fuels and chemicals. However, the most accurate method of biomass sugar analysis is based on the gas chromatography analysis of derivatized sugars either as alditol acetates or trimethylsilanes. The derivatization method is time consuming but the alternative high-performance liquid chromatography (HPLC) method cannot resolve most sugars found in biomass hydrolysates. We have demonstrated for the first time that by careful manipulation of the HPLC mobile phase, biomass monomeric sugars (arabinose, xylose, fructose, glucose, mannose, and galactose) can be analyzed quantitatively andmore » there is excellent baseline resolution of all the sugars. This method was demonstrated for standard sugars, pretreated corn stover liquid and solid fractions. Our method can also be used to analyze dimeric sugars (cellobiose and sucrose).« less
Hayashi, Hideki; Kita, Yutaro; Iihara, Hirotoshi; Yanase, Koumei; Ohno, Yasushi; Hirose, Chiemi; Yamada, Maya; Todoroki, Kenichiro; Kitaichi, Kiyoyuki; Minatoguchi, Shinya; Itoh, Yoshinori; Sugiyama, Tadashi
2016-07-01
A simultaneous, selective, sensitive and rapid liquid chromatography/tandem mass spectrometry method was developed and validated for the quantification of gefitinib, erlotinib and afatinib in 250 μL samples of human blood plasma. Diluted plasma samples were extracted using a liquid-phase extraction procedure with tert-butyl methyl ether. The three drugs were separated by high-performance liquid chromatography using a C18 column and an isocratic mobile phase running at a flow rate of 0.2 mL/min for 5 min. The drugs were detected using a tandem mass spectrometer with electrospray ionization using imatinib as an internal standard. Calibration curves were generated over the linear concentration range of 0.05-100 nm in plasma with a lower limit of quantification of 0.01 or 0.05 nm for all compounds. Finally, the validated method was applied to a clinical pharmacokinetic study in patients with nonsmall-cell lung cancer (NSCLC) following the oral administration of afatinib. These results indicate that this method is suitable for assessing the risks and benefits of chemotherapy in patients with NSCLC and is useful for therapeutic drug monitoring for NSCLC treatment. As far as we know, this is the first report on LC-MS/MS method for the simultaneous quantification of NSCLC tyrosine kinase inhibitor plasma concentrations including afatinib. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Poch, G K; Klette, K L; Anderson, C
2000-04-01
This paper compares the potential forensic application of two sensitive and rapid procedures (liquid chromatography-mass spectrometry and liquid chromatography-ion trap mass spectrometry) for the detection and quantitation of 2-oxo-3-hydroxy lysergic acid diethylamide (O-H-LSD) a major LSD metabolite. O-H-LSD calibration curves for both procedures were linear over the concentration range 0-8,000 pg/mL with correlation coefficients (r2) greater than 0.99. The observed limit of detection (LOD) and limit of quantitation (LOQ) for O-H-LSD in both procedures was 400 pg/mL. Sixty-eight human urine specimens that had previously been found to contain LSD by gas chromatography-mass spectrometry were reanalyzed by both procedures for LSD and O-H-LSD. These specimens contained a mean concentration of O-H-LSD approximately 16 times higher than the LSD concentration. Because both LC methods produce similar results, either procedure can be readily adapted to O-H-LSD analysis for use in high-volume drug-testing laboratories. In addition, the possibility of significantly increasing the LSD detection time window by targeting this major LSD metabolite for analysis may influence other drug-free workplace programs to test for LSD.
Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...
USDA-ARS?s Scientific Manuscript database
An easy and reliable high-throughput analysis method was developed and validated for 192 diverse pesticides and 51 environmental contaminants (13 PCB congeners, 14 PAHs, 7 PBDE congeners, and 17 novel flame retardants) in cattle, swine, and poultry muscle. Sample preparation was based on the “quick,...
Zhang, Jian-Long; Kubanek, Julia; Hay, Mark E; Aalbersberg, William; Ye, Wen-Cai; Jiang, Ren-Wang
2011-09-01
Tydemania expeditionis Weber-van Bosse (Udoteaceae) is a weakly calcified green alga. In the present paper, liquid chromatography coupled with photodiode array detection and electrospray mass spectrometry was developed to identify the fingerprint components. A total of four triterpenoid sulfates and three hydroxy fatty acids in the ethyl acetate fraction of the crude extract were structurally characterized on the basis of retention time, online UV spectrum, and mass fragmentation pattern. Furthermore, a detailed liquid chromatography-mass spectrometry analysis revealed two new hydroxy fatty acids, which were then prepared and characterized by extensive nuclear magnetic resonance (NMR) analyses. The proposed method provides a scientific and technical platform for the rapid identification of triterpenoid sulfates and hydroxy fatty acids in similar marine algae and terrestrial plants. Copyright © 2011 John Wiley & Sons, Ltd.
Nano-liquid chromatography applied to enantiomers separation.
Fanali, Salvatore
2017-02-24
This paper presents the state of the art concerning the separation of chiral compounds by means of nano-liquid chromatography (nano-LC). The enantiomers' separation and determination are a subject of fundamental importance in various application fields such as pharmaceutical industry, biomedicine, food, agrochemical etc. Nano-LC is a miniaturized chromatographic technique offering some advantages over conventional ones such as low consumption of mobile phase, sample volume and amount of chiral stationary phase, reduced costs etc. This is reported in the first part of the paper illustrating the features of the nano-LC. In addition, chiral resolution methods are briefly illustrated. Some chiral selectors, used in high-performance liquid chromatography have also been applied in nano-LC including cyclodextrins, glycopeptide antibiotics, modified polysaccharides etc. This is discussed in the second part of the review. Finally some examples of the applications available in literature are reported. Copyright © 2016 Elsevier B.V. All rights reserved.
Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya
2016-01-01
The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification. PMID:27313979
Contemporary Carbon Content of Bis (2-ethylhexyl) Phthalate in Butter
Tong, T.; Ondov, J. M.; Buchholz, B. A.; VanDerveer, M. C.
2016-01-01
The fraction of naturally produced Bis (2-ethylhexyl) phthalate (DEHP), a ubiquitous plasticizer known to contaminate packaged foods, was determined for each of five 1.10 kg samples of unsalted market butter by accelerator mass spectrometry (AMS). After extraction and concentration enrichment with liquid-liquid extraction, flash column chromatography, and preparative-scale high performance liquid chromatography, each sample provided ≈250 µg extracts of DEHP with carbon purity ranging from 92.5±1.2% (n=3, 1σ) to 97.1±0.8% (n=3, 1σ) as measured with gas chromatography mass spectrometry (GC-MS). After corrections for method blank DEHP, co-eluting compounds, and unidentified carbon, the mean fraction of naturally produced DEHP in butter was determined to be 0.16±0.12 (n=5, 1σ). To our knowledge, this is the first report of the contemporary fraction of DEHP isolated from market butter in the U.S. PMID:26213077
Zhao, Ying-Yong; Qin, Xiang-Yang; Cheng, Xian-Long; Liu, Xue-Ying; Lin, Rui-Chao; Zhang, Yongmin; Li, Xiao-Ye; Sun, Xiao-Li; Sun, Wen-Ji
2010-08-24
Ergosta-4,6,8(14),22-tetraen-3-one (ergone) from many medicinal plants has been demonstrated to possess a variety of pharmacological activities in vivo and in vitro, including cytotoxic, diuretic and immunosuppressive activity. Metabolism and pharmacokinetic studies on rat were conducted for ergone. Rapid resolution liquid chromatography with atmospheric pressure chemical ionization tandem multi-stage mass spectrometry (RRLC-APCI-MS(n)) and high-performance liquid chromatography with fluorescence detection (HPLC-FLD) methods were applied for the identification and quantification of ergone and its metabolite from rat plasma, faeces and urine. A metabolite was identified by RRLC-DAD-APCI-MS(n): 22,23-epoxy-ergosta-4,6,8(14)-triaen-3-one (epoxyergone). The concentrations of the analyte with its metabolites were determined by HPLC-FLD at excitation wavelength of 370 nm and emission wavelength of 485 nm. The samples were deproteinized with methanol after addition of camptothecin as internal standard (IS). The analysis was performed on a Diamonsil C18 column (150 mm x 4.6 mm x 5 microm) with a mobile phase gradient consisting of methanol and water at a flow rate of 1 mL min(-1). The assay was linear over the concentration range of 42-1500, 36-7500 and 42-1500 ng mL(-1) for plasma, faecal homogenate and urine respectively. The absolute recoveries were found to be 97.0+/-1.2%, 98.1+/-0.7% and 96.6+/-1.8% for plasma, faecal homogenate and urine respectively. The intra-day and inter-day relative standard deviations (RSD) were less than 10%. The previous HPLC-MS/MS method is not affordable for most laboratories because of the specialty requirement and high equipment cost. However, the HPLC-FLD method is economic and operating simply for quantitative determination of ergone and its metabolite in rat plasma, faeces and urine. In addition, liquid chromatography coupled with ion trap multi-stage mass spectrometry is becoming a useful technique for ergone metabolite identification. 2010 Elsevier B.V. All rights reserved.
Determination of Ivermectin in Medicated Feeds by Liquid Chromatography with Fluorescence Detection
2013-01-01
A labour- and time-effective analytical procedure for determination of ivermectin in medicated feed at recommended level of 2.0 mg kg−1 has been developed and validated. The analyte was extracted from grinded feed samples with acetonitrile and derivatisated with N-methylimidazole and trifluoracetic anhydride. The fluorescent derivatives were analysed by liquid chromatography method using C8 column. The isocratic conditions using acetonitrile, methanol, water, and tetrahydrofuran were applied. Fluorescence detection was performed at 365 nm (excitation) and 475 nm (emission) wavelengths. The total analysis time was 10 min. The validation results of the method (within-laboratory reproducibility 4.0% CV, mean recovery 100.1%) confirm the appropriate precision and accuracy of the developed method. PMID:24453835
Mathias, Patricia I.; B’Hymer, Clayton
2016-01-01
This review describes recent selected HPLC/MS methods for the determination of urinary mercapturates that are useful as non-invasive biomarkers in characterizing human exposure to electrophilic industrial chemicals in occupational and environmental studies. High performance liquid chromatography/mass spectrometry is a sensitive and specific method for analysis of small molecules found in biological fluids. In this review, recent selected mercapturate quantification methods are summarized and specific cases are presented. The biological formation of mercapturates is introduced and their use indicators of metabolic processing of reactive toxicants is discussed, as well as future trends and limitations in this area of research. PMID:26900903
Vikram, Amit; Jayaprakasha, G K; Patil, Bhimanagouda S
2007-05-08
High performance liquid chromatography (HPLC) method has been developed for simultaneous quantification of limonoid aglycones and glucosides on a reversed phase C18 column using a binary solvent system, coupled with diode array detector. Seven limonoids such as limonin, nomilin, isolimonic acid, ichangin, isoobacunoic acid, limonin 17-beta-D glucopyranoside and deacetyl nomilinic acid 17-beta-D glucopyranoside were separated and detected at 210 nm. Furthermore, limonoids were separated, identified and quantified in four varieties of citrus fruits and seeds using developed method. Limonin and limonin glucoside were found to be the predominant limonoid aglycone and glucoside, respectively, in all tested samples. The sensitivity of the method was found to be 0.25-0.50 microg for tested limonoids.
liquid chromatography analysis Bench-scale methods Education B.S., Chemistry (Mathematics Minor), Adams ;Improved methods for the determination of drying conditions and fraction insoluble solids (FIS) in biomass
DOE Office of Scientific and Technical Information (OSTI.GOV)
C.J. Miller; G. Elias; N.C. Schmitt
2010-06-01
High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to specifically identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol using no sample cleanup prior to analysis. The methanol extracts were injected directly into several different column types and analyzed by HPLC-UV and/or GC-ECD. This paper describes general screening methods that weremore » used to determine the presence of explosives in unknown samples and techniques that have been optimized for quantification of each explosive from the substrate extracts.« less
Wang, Yun; Liu, Hui; Shen, Lifeng; Yao, Lan; Ma, Yinlian; Yu, Dingrong; Chen, Jianhong; Li, Puling; Chen, Ying; Zhang, Cun
2015-12-01
Gardeniae fructus is one of the most frequently used herbs in traditional Chinese medicine. In the present study, a process for the enrichment of six iridoid glycosides from Gardeniae fructus was developed using medium-pressure liquid chromatography combined with macroporous resin and reversed-phase chromatography. The purities of different fractions from Gardeniae fructus were assessed using quantitative high-performance liquid chromatography. After fractionation using HPD-100 column chromatography, a 30% ethanol fraction was selected based on high-performance liquid chromatography and liquid chromatography with mass spectrometry qualitative analysis to separate and purify. Based on the orientation analysis results, six compounds-deacetyl asperulosidic acid methyl ester, gardenoside, ixoroside, scandoside methyl ester, genipin-1-O-β-d-gentiobioside, and geniposide-were successfully isolated and purified in three to four combined steps from Gardeniae fructus. The purities of these compounds were found by high-performance liquid chromatography analysis to be 97.9, 98.1, 95.5, 96.3, 97.1, and 98.7%, respectively. Moreover, their structures were elucidated by NMR spectroscopy and liquid chromatography with tandem mass spectrometry. The separation process was highly efficient, rapid, and accurate, making it a potential approach for the large-scale production of iridoids in the laboratory and providing several marker compounds for quality control. This procedure may be meaningful for the purification of other natural products used in traditional Chinese medicine. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, Jian; Milne, Robert W.; Nation, Roger L.; Turnidge, John D.; Coulthard, Kingsley; Valentine, Jason
2002-01-01
A simple and sensitive high-performance liquid chromatographic method is described for the determination of colistimethate sodium in plasma and urine. The accuracy and reproducibility was within 10.1 and 11.2% with rat plasma and urine, respectively. Several commonly coadministered antibacterial agents do not interfere with the assay. PMID:12234867
Shen, Xiong; Liang, Jian; Zheng, Luxia; Lv, Qianzhou; Wang, Hong
2017-11-01
A simple and sensitive method for the simultaneous determination of eight parabens in human plasma and urine samples was developed. The samples were preconcentrated using dispersive liquid-liquid microextraction based on the solidification of floating organic drops and determined by high-performance liquid chromatography with ultraviolet detection. The influence of variables affecting the extraction efficiency was investigated and optimized using Placket-Burman design and Box-Behnken design. The optimized values were: 58 μL of 1-decanol (as extraction solvent), 0.65 mL methanol (as disperser solvent), 1.5% w/v NaCl in 5.0 mL of sample solution, pH 10.6, and 4.0 min centrifugation at 4000 rpm. The extract was injected into the high-performance liquid chromatography system for analysis. Under the optimum conditions, the linear ranges for eight parabens in plasma and urine were 1.0-1000 ng/mL, with correlation coefficients above 0.994. The limit of detection was 0.2-0.4 and 0.1-0.4 ng/mL for plasma and urine samples, respectively. Relative recoveries were between 80.3 and 110.7%, while relative standard deviations were less than 5.4%. Finally, the method was applied to analyze the parabens in 98 patients of primary breast cancer. Results showed that parabens existed widely, at least one paraben detected in 96.9% (95/98) of plasma samples and 98.0% (96/98) of urine samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Analysis of penicillin G in milk by liquid chromatography.
Boison, J O; Keng, L J; MacNeil, J D
1994-01-01
A liquid chromatographic (LC) method that was previously developed for penicillin G residues in animal tissues has been adapted to milk and milk products. After protein precipitation with sodium tungstate, samples are applied to a C18 solid-phase extraction cartridge, from which penicillin is eluted, derivatized with 1,2,4-triazole-mercuric chloride solution, and analyzed by isocratic liquid chromatography (LC) on a C18 column with UV detection at 325 nm. Quantitation is done with reference to penicillin V as an internal standard. Penicillin G recoveries were determined to be > 70% on standards fortified at 3-60 ppb. Accuracy approached 100% using the penicillin V internal standard. The detection limit for penicillin G residues was 3 ppb in fluid milk. Samples may be confirmed by thermospray/LC at concentrations approaching the detection limit of the UV method.
Liquid Chromatography in 1982.
ERIC Educational Resources Information Center
Freeman, David H.
1982-01-01
Reviews trends in liquid chromatography including apparatus, factors affecting efficient separation of a mixture (peak sharpness and speed), simplified problem-solving, adsorption, bonded phase chromatography, ion selectivity, and size exclusion. The current trend is to control chemical selectivity by the liquid phase. (Author/JN)
Kumar, Ashwini; Singh, Baldev; Malik, Ashok Kumar; Tiwary, Dhananjay K
2007-01-01
A new approach has been developed for the extraction and determination of aldehydes such as veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde by using solid-phase microextraction (SPME) and high-performance liquid chromatography with UV detection (HPLC/UV). The method involves adsorption of the aldehydes on polydimethylsiloxane/divinylbenzene-coated fiber, followed by desorption in the desorption chamber of the SPME-HPLC interface, using acetonitrile-water (70 + 30) as the mobile phase; UV detection was at 254 nm. A good separation of 5 aldehydes was obtained on a C18 column. The detection limits of veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde are 25, 41, 13, 12, and 11 pg/mL, respectively, which are about 100 times better than the detection limits for other SPME methods using gas chromatography. The proposed method was validated by determining benzaldehyde in bitter almonds and cinnamaldehyde in cinnamon bark. The recoveries of the 5 analytes were determined by analysis of spiked drinking water.
Lepom, P
1988-09-01
A method for the determination of zearalenone in maize and maize silage was developed which distinguishes itself by the effective and fast cleaning of the extracts with the help of a silica gel minicolumn. The samples were extracted with chloroform/methanol (9 + 1) and cleaned on a silica gel minicolumn after acid-base partition. The zearalenone was quantitatively determined optionally by means of high-performance liquid chromatography (HPLC) with fluorescence detection (excitation wavelength 236 nm, emission filter 418 nm) or thin-layer chromatography (TLC), p-methoxybenzene diazonium fluoroborate and aluminium chloride were used as detection chemicals. The limits of detection are 0.01 mg/kg (HPLC) and 0.1 mg/kg resp. (TLC), the average recovery is 81%. The method was used for the determination of zearalenone in grain maize, CCM silage and silage from whole maize plants.
Zhang, Chunyu; Wang, Hui; Zhang, Xiaohui; Ma, Zhongqiang; Deng, Wanmei; Hu, Ke; Ding, Mingyu
2011-12-01
A method of gel permeation chromatography-high performance liquid chromatography (GPC-HPLC) was established for the simultaneous determination of 5 main phthalate plasticizers in foods (edible oil, instant noodles, fried pastries, Saqima, etc.). The samples were extracted with petroleum ether in an ultrasonator, purified by a GPC column, and analyzed by HPLC. The chromatographic separation was achieved on a Labtech-C18 column (250 mm x 4.6 mm, 5 microm) using acetonitrile and water mixture as the mobile phases in a gradient elution mode. The developed method exhibited a linear correlation coefficient of more than 0.997 and the detection limits of 3.25 - 13.4 microg/L. The spike recoveries were between 70.4% and 113.6% with the relative standard deviations (RSDs, n = 3) of 0.3% - 5.8% at the spiked level of 50 mg/L. This method is simple, rapid and practical, and can be used for the simultaneous determination of PAEs in grease food samples.
The Analytical Chemistry of Drug Monitoring in Athletes
NASA Astrophysics Data System (ADS)
Bowers, Larry D.
2009-07-01
The detection and deterrence of the abuse of performance-enhancing drugs in sport are important to maintaining a level playing field among athletes and to decreasing the risk to athletes’ health. The World Anti-Doping Program consists of six documents, three of which play a role in analytical development: The World Anti-Doping Code, The List of Prohibited Substances and Methods, and The International Standard for Laboratories. Among the classes of prohibited substances, three have given rise to the most recent analytical developments in the field: anabolic agents; peptide and protein hormones; and methods to increase oxygen delivery to the tissues, including recombinant erythropoietin. Methods for anabolic agents, including designer steroids, have been enhanced through the use of liquid chromatography/tandem mass spectrometry and gas chromatography/combustion/isotope-ratio mass spectrometry. Protein and peptide identification and quantification have benefited from advances in liquid chromatography/tandem mass spectrometry. Incorporation of techniques such as flow cytometry and isoelectric focusing have supported the detection of blood doping.
Asea, P A; Patterson, J R; Korsrud, G O; Dowling, P M; Boison, J O
2001-01-01
A new and sensitive liquid chromatography-ultra violet method with a detection limit of 6 ng/g (ppb) and a limit of quantification of 15 ng/g was developed for the determination of flunixin residues in bovine muscle tissue. Flunixin in homogenized animal tissue was extracted with acetonitrile after enzyme digestion. The tissue digest (extract) was then cleaned up on a solid-phase extraction cartridge and eluted with acidified hexane. After the eluate was evaporated to dryness under nitrogen at 55 degrees C, the residue was reconstituted in 1 mL mobile phase solution and analyzed by reversed-phase gradient chromatography with UV detection at 285 nm. The method was then applied in a survey study of slaughter animals to determine whether flunixin is being used in an off-label manner for veal and beef production in Canada.
Wang, Ping; Liu, Yongling; Chen, Tao; Xu, Wenhua; You, Jinmao; Liu, Yongjun; Li, Yulin
2013-01-01
Lignans and flavonols are the primary constituents of Sinopodophyllum emodi and have been used as cathartic, anthelmintic, chemotherapeutic and anti-hypertensive compounds. Although these compounds have been isolated, there have been no reports on the separation of 4'-demethyl podophyllotoxin, podophyllotoxin, deoxypodophyllotoxin and kaempferol in one step by medium-pressure liquid chromatography (MPLC) and high-speed counter-current chromatography (HSCCC). Development of an efficient method for the preparative separation and purification of three lignans and one flavonol from S. emodi. The precipitate of crude extracts was first separated by MPLC into four parts, numbered GJ-1, GJ-2, GJ-3 and GJ-4. GJ-1 was separated and purified by HSCCC using a solvent system composed of n-hexane:ethyl acetate:methanol:water (1.75:1.5:1:0.75, v/v/v/v). The purities of the target compounds were assessed using high-performance liquid chromatography (HPLC) and chemical structures were identified by (1) H-NMR and (13) C-NMR. The HSCCC and MPLC methods were successfully used for the preparative separation and purification of 4'-demethyl podophyllotoxin (8.5 mg, 92.4%), podophyllotoxin (40.1 mg, 92.1%), deoxypodophyllotoxin (4.6 mg, 98.1%), and kaempferol (1.6 mg, 96.7%) from a 100 mg sample. Three lignans (4'-demethyl podophyllotoxin, podophyllotoxin, deoxypodophyllotoxin) and one flavonol (kaempferol) were successfully isolated by HSCCC and MPLC in one step. Copyright © 2013 John Wiley & Sons, Ltd.
Qu, Jing; Hu, You-cai; Li, Jian-bei; Wang, Ying-hong; Zhang, Jin-lan; Abliz, Zeper; Yu, Shi-shan; Liu, Yun-bao
2008-01-01
A combination of electrospray ionization tandem mass spectrometry with high-performance liquid chromatography (HPLC/ESI-MSn), and hyphenation of liquid chromatography to nuclear magnetic resonance spectroscopy (HPLC/NMR), have been extensively utilized for on-line analysis of natural products, analyzing metabolite and drug impurity. In our last paper, we reported an on-line analytical method for structural identification of trace alkaloids in the same class. However, the structural types of the constituents in plants were various, such as flavanoids, terpenoids and steroids. It is important to establish an effective analytical method for on-line structural identification of constituents with molecular diversity in extracts of plants. So, in the present study, the fragmentation patterns of some isolated stilbenes, phloroglucinols and flavanoids from Lysidice rhodostegia were investigated by ESI-MSn. Their fragmentation rules and UV characteristics are summarized, and the relationship between the spectral characteristics, rules and the structures is described. According to the fragmentation rules, NMR and UV spectral characteristics, 24 constituents of different types in the fractions from L. brevicalyx of the same genus were structurally characterized on the basis of HPLC/HRMS, HPLC-UV/ESI-MSn, HPLC/1H NMR and HPLC/1H-1H COSY rapidly. Of these, six (10, 13, 14, 16, 17 and 23) are new compounds and all of them are reported from L. brevicalyx for the first time. The aim is to develop an effective analytical method for on-line structural identification of natural products with molecular diversity in plants, and to guide the rapid and direct isolation of novel compounds by chemical screening.
Burton, Casey; Shi, Honglan; Ma, Yinfa
2013-11-19
Recent preliminary studies have implicated urinary pteridines as candidate biomarkers in a growing number of malignancies including breast cancer. While the developments of capillary electrophoresis-laser induced fluorescence (CE-LIF), high performance liquid chromatography (HPLC), and liquid chromatography-mass spectroscopy (LC-MS) pteridine urinalyses among others have helped to enable these findings, limitations including poor pteridine specificity, asynchronous or nonexistent renal dilution normalization, and a lack of information regarding adduct formation in mass spectrometry techniques utilizing electrospray ionization (ESI) have prevented application of these techniques to a larger clinical setting. In this study, a simple, rapid, specific, and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and optimized for simultaneous detection of six pteridines previously implicated in breast cancer and creatinine as a renal dilution factor in urine. In addition, this study reports cationic adduct formation of urinary pteridines under ESI-positive ionization for the first time. This newly developed technique separates and detects the following six urinary pteridines: 6-biopterin, 6-hydroxymethylpterin, d-neopterin, pterin, isoxanthopterin, and xanthopterin, as well as creatinine. The method detection limit for the pteridines is between 0.025 and 0.5 μg/L, and for creatinine, it is 0.15 μg/L. The method was also validated by spiked recoveries (81-105%), reproducibility (RSD: 1-6%), and application to 25 real urine samples from breast cancer positive and negative samples through a double-blind study. The proposed technique was finally compared directly with a previously reported CE-LIF technique, concluding that additional or alternative renal dilution factors are needed for proper investigation of urinary pteridines as breast cancer biomarkers.
Ojanperä, Suvi; Rasanen, Ilpo; Sistonen, Johanna; Pelander, Anna; Vuori, Erkki; Ojanperä, Ilkka
2007-08-01
Lack of availability of reference standards for drug metabolites, newly released drugs, and illicit drugs hinders the analysis of these substances in biologic samples. To counter this problem, an approach is presented here for quantitative drug analysis in plasma without primary reference standards by liquid chromatography-chemiluminescence nitrogen detection (LC-CLND). To demonstrate the feasibility of the method, metabolic ratios of the opioid drug tramadol were determined in the setting of a pharmacogenetic study. Four volunteers were given a single 100-mg oral dose of tramadol, and a blood sample was collected from each subject 1 hour later. Tramadol, O-desmethyltramadol, and nortramadol were determined in plasma by LC-CLND without reference standards and by a gas chromatography-mass spectrometry reference method. In contrast to previous CLND studies lacking an extraction step, a liquid-liquid extraction system was created for 5-mL plasma samples using n-butyl chloride-isopropyl alcohol (98 + 2) at pH 10. Extraction recovery estimation was based on model compounds chosen according to their similar physicochemical characteristics (retention time, pKa, logD). Instrument calibration was performed with a single secondary standard (caffeine) using the equimolar response of the detector to nitrogen. The mean differences between the results of the LC-CLND and gas chromatography-mass spectrometry methods for tramadol, O-desmethyltramadol, and nortramadol were 8%, 32%, and 19%, respectively. The sensitivity of LC-CLND was sufficient for therapeutic concentrations of tramadol and metabolites. A good correlation was obtained between genotype, expressed by the number of functional genes, and the plasma metabolite ratios. This experiment suggests that a recovery-corrected LC-CLND analysis produces sufficiently accurate results to be useful in a clinical context, particularly in instances in which reference standards are not readily accessible.
NASA Technical Reports Server (NTRS)
1983-01-01
The general principles of classical liquid chromatography and high pressure liquid chromatography (HPLC) are reviewed, and their advantages and disadvantages are compared. Several chromatographic techniques are reviewed, and the analytical separation of a C-ether liquid lubricant by each technique is illustrated. A practical application of HPLC is then demonstrated by analyzing a degraded C-ether liquid lubricant from full scale, high temperature bearing tests.
Chromatographic and electrophoretic approaches in ink analysis.
Zlotnick, J A; Smith, F P
1999-10-15
Inks are manufactured from a wide variety of substances that exhibit very different chemical behaviors. Inks designed for use in different writing instruments or printing methods have quite dissimilar components. Since the 1950s chromatographic and electrophoretic methods have played important roles in the analysis of inks, where compositional information may have bearing on the investigation of counterfeiting, fraud, forgery, and other crimes. Techniques such as paper chromatography and electrophoresis, thin-layer chromatography, high-performance liquid chromatography, gas chromatography, gel electrophoresis, and the relatively new technique of capillary electrophoresis have all been explored as possible avenues for the separation of components of inks. This paper reviews the components of different types of inks and applications of the above separation methods are reviewed.
Zhao, Lu; Wen, E; Upur, Halmuart; Tian, Shuge
2017-01-01
Context: Sea buckthorn (Hippophae rhamnoides L.) as a traditional Chinese medicinal plant has various uses in Xinjiang. Objective: A reversed-phase rapid-resolution liquid-chromatography method with diode array detector was developed for simultaneous determination of protocatechuic acid, rutin, quercetin, kaempferol, and isorhamnetin in the pulp and seed of sea buckthorn, a widely used traditional Chinese medicine for promoting metabolism and treating scurvy and other diseases. Settings and design: Compounds were separated on an Agilent ZORBAX SB-C18 column (4.6 mm × 250 mm, 5 μm; USA) with gradient elution using methanol and 0.4% phosphoric acid (v/v) at 1.0 mL/min. Detection wavelength was set at 280 nm. Materials and Methods: The fruits of wild sea buckthorn were collected from Wushi County in Aksu, Xinjiang Province. Statistical performances: The RSD of precision test of the five compounds were in the range of 0.60-2.22%, and the average recoveries ranged from 97.36% to 101.19%. Good linearity between specific chromatographic peak and component qualities were observed in the investigated ranges for all the analytes (R2 > 0.9997). Results: The proposed method was successfully applied to determine the levels of five active components in sea buckthorn samples from Aksu in Xinjiang. Conclusions: The proposed method is simple, fast, sensitive, accurate, and suitable for quantitative assessment of the pulp and seed of sea buckthorn. SUMMARY Quantitative analysis method of protocatechuic acid, rutin, quercetin, kaempferol, and isorhamnetin in the extract of sea buckthorn pulp and seed is developed by high-performance liquid chromatography (HPLC) diode array detection.This method is simple and accurate; has strong specificity, good precision, and high recovery rate; and provides a reliable basis for further development of the substances in the pulp and seed of sea buckthorn.The method is widely used for content determination of active ingredients or physiologically active components in traditional Chinese medicine and its preparation Abbreviation used: PR: protocatechuic acid, RU: rutin, QU: quercetin, KA: kaempferol, IS: isorhamnetin, HPLC: high-performance liquid chromatography, HPLC-DAD: high performance liquid chromatographydiode array detector, LOD: linearity and limit of detection, LOQ: limit of quantitation, RSD: relative standard deviation PMID:28216897
Schalk, Kathrin; Koehler, Peter; Scherf, Katharina Anne
2018-01-01
Celiac disease (CD) is an inflammatory disorder of the upper small intestine caused by the ingestion of storage proteins (prolamins and glutelins) from wheat, barley, rye, and, in rare cases, oats. CD patients need to follow a gluten-free diet by consuming gluten-free products with gluten contents of less than 20 mg/kg. Currently, the recommended method for the quantitative determination of gluten is an enzyme-linked immunosorbent assay (ELISA) based on the R5 monoclonal antibody. Because the R5 ELISA mostly detects the prolamin fraction of gluten, a new independent method is required to detect prolamins as well as glutelins. This paper presents the development of a method to quantitate 16 wheat marker peptides derived from all wheat gluten protein types by liquid chromatography tandem mass spectrometry (LC-MS/MS) in the multiple reaction monitoring mode. The quantitation of each marker peptide in the chymotryptic digest of a defined amount of the respective reference wheat protein type resulted in peptide-specific yields. This enabled the conversion of peptide into protein type concentrations. Gluten contents were expressed as sum of all determined protein type concentrations. This new method was applied to quantitate gluten in wheat starches and compared to R5 ELISA and gel-permeation high-performance liquid chromatography with fluorescence detection (GP-HPLC-FLD), which resulted in a strong correlation between LC-MS/MS and the other two methods.
Kovac, Andrej; Somikova, Zuzana; Zilka, Norbert; Novak, Michal
2014-02-01
Alzheimer's disease (AD) is still being recognized today as an unmet medical need. Currently, there is no cure and early preclinical diagnostic assay available for AD. Therefore much attention is now being directed at the development of novel methods for quantitative determination of AD biomarkers in the cerebrospinal fluid (CSF). Here, we describe the liquid chromatography-tandem mass spectrometry method for determination of 5-hydroxytryptamine (SER), 5-hydroxyindoleacetic acid (5-HIAA), homovanilic acid (HVA), noradrenaline (NADR), adrenaline (ADR), dopamine (DA), glutamic acid (Glu), γ-aminobutyric acid (GABA), 3,4-dihydroxyphenylacetic acid (DOPAC) and histamine (HIS) in cerebrospinal fluid (CSF) from the rat model for human tauopathy. The benzoyl chloride was used as pre-column derivatization reagents. Neurotransmitters and metabolites were analysed on ultra performance liquid chromatography (UPLC) on C18 column in combination with tandem mass spectrometry. The method is simple, highly sensitive and showed excellent linearity with regression coefficients higher than 0.99. The accuracy was in a range of 93-113% for all analytes. The inter-day precision (n=5 days), expressed as %RSD, was in a range 2-10% for all analytes. Using this method we detected significant changes of CSF levels of two important neurotransmitters/metabolites, ADR and 5-HIAA, which correlates with progression of neurodegeneration in our animal model. © 2013 Published by Elsevier B.V.
Reddy, Muntha K; Mills, Grier; Nixon, Christopher; Wyatt, Shane A; Croley, Timothy R
2011-08-15
Nitrogen mustards (NMs) are known to have DNA alkylation and strong vesicant properties. Their availability to terrorist organizations makes them a potential choice for chemical attacks on civilian populations. After an exposure, it is difficult to measure NMs directly because of their rapid metabolism in the human body. Therefore to determine an individual's level of exposure to NMs, it is necessary to analyze for NM metabolites being excreted by the body. The metabolites of NMs are generated by a hydrolysis reaction, and are easily detectable by liquid chromatography tandem mass spectrometry (LC-MS/MS). This work is focused on the development of a high-throughput assay for the quantitation of N-ethyldiethanolamine (EDEA) and N-methyldiethanolamine (MDEA) metabolites of bis (2-chloroethyl) ethylethanamine (HN1) and bis (2-chloroethyl) methylethanamine (HN2), respectively. The method uses automated 96-well plate sample preparation of human urine samples and a 2-position 10-port switching valve to allow for simultaneous regeneration of the liquid chromatography (LC) columns. Using this method, over 18 h was saved through the reduction of sample preparation and analysis time when compared to a conventional method for 96 samples. The validated method provided excellent accuracy for both EDEA (100.9%) and MDEA (100.6%) with precision better than 5.27% for each analyte. Copyright © 2011 Elsevier B.V. All rights reserved.
Isakau, Henadz; Robert, Marielle; Shingel, Kirill I
2009-04-05
The paper describes the development and validation of a new derivatization-free liquid chromatography method for simultaneous determination of propylene glycol and formaldehyde in the formulations containing formaldehyde-releasing preservative. Highly swollen hydrogel made of poly(ethylene glycol)-protein conjugates was taken as a model formulation for integration of the propylene glycol and the diazolydinyl urea as formaldehyde releaser. The method is shown to be simple and selective and, more importantly, allows determining an existing level of formaldehyde at the moment of analysis instead of all available formaldehyde that might be released during chemical derivatization. After liquid extraction the propylene glycol (PG) and formaldehyde (FA) amounts are determined chromatographically on a Shodex SH 1011 ligand-exchange column using 0.01 M sulfuric acid mobile phase, a flow rate of 1.0 ml/min and RI detection. The assay is validated showing good linearity, precision, and accuracy. The limits of detection of formaldehyde and propylene glycol in the analyzed solutions were estimated to be 25 ng and 87 ng, respectively. This analytical assay is considered useful for product stability studies and in developing new formaldehyde releaser-containing formulations where the concentration of formaldehyde is a presumable subject of labeling requirements. This method can also provide a rapid and convenient alternative to gas chromatography method of propylene glycol quantification.
St-Germain, G; Lapierre, S; Tessier, D
1989-01-01
We compared the accuracy and precision of two microbiological methods and one high-pressure liquid chromatography (HPLC) procedure used to measure the concentrations of flucytosine in serum. On the basis of an analysis of six standards, all methods were judged reliable within acceptable limits for clinical use. With the biological methods, a slight loss of linearity was observed in the 75- to 100-micrograms/ml range. Compared with the bioassays, the HPLC method did not present linearity problems and was more precise and accurate in the critical zone of 100 micrograms/ml. On average, results obtained with patient sera containing 50 to 100 micrograms of flucytosine per ml were 10.6% higher with the HPLC method than with the bioassays. Standards for the biological assays may be prepared in serum or water. PMID:2802566
Ge, Liya; Yong, Jean Wan Hong; Goh, Ngoh Khang; Chia, Lian Sai; Tan, Swee Ngin; Ong, Eng Shi
2005-12-27
Kinetin (free base and riboside), which was assumed by many scientists to be a synthetic cytokinin plant growth hormone, has been detected for the first time in the endosperm liquid of fresh young coconut fruits ("coconut water"). To facilitate the study, we developed a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the identification and quantification of kinetin and kinetin riboside in purified coconut water extract sample. Following a solid-phase extraction of cytokinins in coconut water using C18 columns, the samples were further purified by Oasis MCX columns and analyzed by LC-MS/MS for kinetin and kinetin riboside. Detection by mass spectrometry was carried out using selected reaction monitoring (SRM) mode, by identifying the putative kinetin and kinetin riboside based on their characteristic fragments. Based on a signal-to-noise ratio of 3, the limits of detection in SRM mode were 0.02 microM and 0.005 microM for kinetin and kinetin riboside, respectively. Furthermore, optimal conditions for a baseline chromatographic separation of 18 cytokinin standards by high performance liquid chromatography (HPLC) were developed. The HPLC method had been employed for the confirmation and further fractionation of kinetin in coconut water extracts. The confirmation and fractionation of kinetin riboside was carried out using a further modified HPLC program due to the presence of other interfering material(s) in the sample matrix. Finally, fractions of putative kinetin and kinetin riboside collected from HPLC eluate of coconut water sample were further authenticated by independent capillary zone electrophoresis (CZE) experiment.
[High-performance liquid-liquid chromatography in beverage analysis].
Bricout, J; Koziet, Y; de Carpentrie, B
1978-01-01
Liquid liquid chromatography was performed with columns packed with stationary phases chemically bonded to silica microparticules. These columns show a high efficiency and are used very easily. Flavouring compounds like aromatic aldehydes which have a low volatility were analyzed in brandy using a polar phase alkylnitrile. Sapid substances like amarogentin in Gentiana lutea or glyryrrhizin in Glycyrrhiza glabra were determined by reversed phase chromatography. Finally ionizable substances like synthetic dyes can be analyzed by paired ion chromatography witha non polar stationary phase.
Bahmanabadi, L; Akhgari, M; Jokar, F; Sadeghi, H B
2017-02-01
Methamphetamine abuse is one of the most medical and social problems many countries face. In spite of the ban on the use of methamphetamine, it is widely available in Iran's drug black market. There are many analytical methods for the detection of methamphetamine in biological specimen. Oral fluid has become a popular specimen to test for the presence of methamphetamine. The purpose of the present study was to develop a method for the extraction and detection of methamphetamine in oral fluid samples using liquid-liquid extraction (LLE) and gas chromatography/mass spectrometry (GC/MS) methods. An analytical study was designed in that blank and 50 authentic oral fluid samples were collected to be first extracted by LLE and subsequently analysed by GC/MS. The method was fully validated and showed an excellent intra- and inter-assay precision (reflex sympathetic dystrophy ˂ 10%) for external quality control samples. Recovery with LLE methods was 96%. Limit of detection and limit of quantitation were 5 and 15 ng/mL, respectively. The method showed high selectivity, no additional peak due to interfering substances in samples was observed. The introduced method was sensitive, accurate and precise enough for the extraction of methamphetamine from oral fluid samples in forensic toxicology laboratories.
Sun, Lirui; Jia, Longfei; Xie, Xing; Xie, Kaizhou; Wang, Jianfeng; Liu, Jianyu; Cui, Lulu; Zhang, Genxi; Dai, Guojun; Wang, Jinyu
2016-02-01
In this present study, we developed a simple, rapid and specific method for the quantitative analysis of the contents of amoxicillin (AMO), AMO metabolites and ampicillin (AMP) in eggs. This method uses a simple liquid-liquid extraction with acetonitrile followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The optimized method has been validated according to requirements defined by the European Union and Food and Drug Administration. Extraction recoveries of the target compounds from the egg at 5, 10 and 25 μg/kg were all higher than 80%, with relative standard deviations not exceeding 10.00%. The limits of quantification in eggs were below the maximum residue limits (MRLs). The decision limits (CCα) ranged between 11.1 and 11.5 μg/kg, while detection capabilities (CCβ) from 12.1 to 13.0 μg/kg. These values were very close to the corresponding MRLs. Finally, the new approach was successfully verified for the quantitative determination of these analytes in 40 commercial eggs from local supermarkets. Copyright © 2015 Elsevier Ltd. All rights reserved.
Garver, W S; Kemp, J D; Kuehn, G D
1992-12-01
Acyl-CoA:alcohol transacylase catalyzes the final step in the biosynthesis of storage liquid wax esters from acyl-CoA fatty acids and fatty alcohols in a limited number of microbes, algae, and Simmondsia chinensis Link (jojoba). An improved and automated method of enzyme assay for this catalyst from cotyledons of jojoba is described. The assay method uses reversed-phase C18 high performance liquid chromatography (HPLC) to separate the labeled C30:1 liquid wax product, [14C]-dodecanyl-octadecenoate, from the unreacted substrate, [14C]octadecenoyl-CoA (oleyl-CoA), and other components produced from enzymes present in the crude homogenate of jojoba cotyledons, including [14C]-octadecenoic acid (oleic acid) and [14C]octadecenol (oleyol). Methods are also described for microscale chemical synthesis in one vessel of 14C-radiolabeled substrates and products for the transacylase. These labeled reagents are required to confirm the HPLC separations of reaction products. The radioactive components are quantitated using an on-line flow-through scintillation detector enabling sensitive and precise analysis of the reaction products.
Hou, Xiaohong; Zheng, Xin; Zhang, Conglu; Ma, Xiaowei; Ling, Qiyuan; Zhao, Longshan
2014-10-15
A novel ultrasound-assisted dispersive liquid-liquid microextraction based on solidification of floating organic droplet method (UA-DLLME-SFO) combined with gas chromatography (GC) was developed for the determination of eight pyrethroid pesticides in tea for the first time. After ultrasound and centrifugation, 1-dodecanol and ethanol was used as the extraction and dispersive solvent, respectively. A series of parameters, including extraction solvent and volume, dispersive solvent and volume, extraction time, pH, and ultrasonic time influencing the microextraction efficiency were systematically investigated. Under the optimal conditions, the enrichment factors (EFs) were from 292 to 883 for the eight analytes. The linear ranges for the analytes were from 5 to 100μg/kg. The method recoveries ranged from 92.1% to 99.6%, with the corresponding RSDs less than 6.0%. The developed method was considered to be simple, fast, and precise to satisfy the requirements of the residual analysis of pyrethroid pesticides. Copyright © 2014 Elsevier B.V. All rights reserved.
Jäpelt, Rie Bak; Jakobsen, Jette
2016-02-01
The objective of this study was to develop a rapid, sensitive, and specific analytical method to study vitamin K1 in fruits and vegetables. Accelerated solvent extraction and solid phase extraction was used for sample preparation. Quantification was done by liquid chromatography tandem mass spectrometry with atmospheric pressure chemical ionization in selected reaction monitoring mode with deuterium-labeled vitamin K1 as an internal standard. The precision was estimated as the pooled estimate of three replicates performed on three different days for spinach, peas, apples, banana, and beetroot. The repeatability was 5.2% and the internal reproducibility was 6.2%. Recovery was in the range 90-120%. No significant difference was observed between the results obtained by the present method and by a method using the same principle as the CEN-standard i.e. liquid-liquid extraction and post-column zinc reduction with fluorescence detection. Limit of quantification was estimated to 0.05 μg/100g fresh weight. Copyright © 2015 Elsevier Ltd. All rights reserved.
Wang, Z; Hennion, B; Urruty, L; Montury, M
2000-11-01
Solid-phase microextraction coupled with high performance liquid chromatography has been studied for the analysis of methiocarb, napropamide, fenoxycarb and bupirimate in strawberries. The strawberries were blended and centrifuged. Then, an aliquot of the resulting extracting solution was subjected to solid-phase microextraction (SPME) on a 60 microns polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre for 45 min at room temperature. The extracted pesticides on the SPME fibre were desorbed into SPME/high performance liquid chromatography (HPLC) interface for HPLC analysis with diode-array detection (DAD). The method is organic solvent-free for the whole extraction process and is simple and easy to manipulate. The detection limits were shown to be at low microgram kg-1 level and the linear response covered the range from 0.05 to 2 mg kg-1 of pesticides in strawberries with a regression coefficient larger than 0.99. A good repeatability with RSDs between 2.92 and 9.25% was obtained, depending on compounds.
Wu, Xinhua; Zhu, Ruizhi; Ren, Zhuoying; Wang, Kai; Mou, Dingrong; Wei, Wanzhi; Miao, Mingming
2009-11-01
A qualitative method for the identification of 5 main glycosidic flavor precursors in tobacco was developed by using ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI MS/MS) and gas chromatography-mass spectrometry (GC-MS). The glycosidic flavor precursors in tobacco were extracted with methanol, cleaned up with an XAD-2 column. The aglycones were later released by enzyme-mediated hydrolysis under the condition of pH 5. The 5 volatile aglycone moieties were identified by GC-MS standard spectra library. The precursor ions of glycosides were determined by using electrospray ionization mass spectrometry in negative ion mode, then the 5 glycosidic flavor precursors were identified by using product ion scan (MS2) finally, using UPLC-ESI MS/MS, separation and identification of 5 glycosidic flavor precursors were accomplished on an RP-C,8 column in the multiple reaction monitoring (MRM) mode by using methanol and acetic acid-ammonium acetate aqueous solution as eluent. This work lays a foundation for the analysis of glycosidic flavor precursors without the standards by using liquid chromatography-mass spectrometry.
Reversed-phase high-performance liquid chromatography of sulfur mustard in water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raghuveeran, C.D.; Malhotra, R.C.; Dangi, R.S.
1993-01-01
A reversed-phase high-performance liquid chromatography method for the detection and quantitation of sulfur mustard (HD) in water is described with detection at 200 nm. The detection based on the solubility of HD in water revealed that extremely low quantities of HD (4 to 5 mg/L) only are soluble. Experience shows that water is still the medium of choice for the analysis of HD in water and aqueous effluents in spite of the minor handicap of its half-life of ca. 4 minutes, which only calls for speedy analysis.
Miksík, I; Vylitová, M; Pácha, J; Deyl, Z
1999-04-16
High-performance liquid chromatography coupled to atmospheric pressure ionization-electrospray ionization mass spectrometry (API-ESI-MS) was investigated for the analysis of corticosterone metabolites; their characterization was obtained by combining the separation on Zorbax Eclipse XDB C18 column (eluted with a methanol-water-acetic acid gradient) with identification using positive ion mode API-ESI-MS and selected ion analysis. The applicability of this method was verified by monitoring the activity of steroid converting enzymes (20beta-hydroxysteroid dehydrogenase and 11beta-hydroxysteroid dehydrogenase) in avian intestines.
Gong, Xiaoqing; Liu, Ji-Hong
2017-01-01
High-performance liquid chromatography (HPLC) is a sensitive, rapid, and accurate technique to detect and characterize various metabolites from plants. The metabolites are extracted with different solvents and eluted with appropriate mobile phases in a designed HPLC program. Polyamines are known to accumulate under abiotic stress conditions in various plant species and thought to provide protection against oxidative stress by scavenging reactive oxygen species. Here, we describe a common method to detect the free polyamines in plant tissues both qualitatively and quantitatively.
Song, Huiying; Vanderheyden, Yoachim; Adams, Erwin; Desmet, Gert; Cabooter, Deirdre
2016-07-15
Diffusion plays an important role in all aspects of band broadening in chromatography. An accurate knowledge of molecular diffusion coefficients in different mobile phases is therefore crucial in fundamental column performance studies. Correlations available in literature, such as the Wilke-Chang equation, can provide good approximations of molecular diffusion under reversed-phase conditions. However, these correlations have been demonstrated to be less accurate for mobile phases containing a large percentage of acetonitrile, as is the case in hydrophilic interaction liquid chromatography. A database of experimentally measured molecular diffusion coefficients of some 45 polar and apolar compounds that are frequently used as test molecules under hydrophilic interaction liquid chromatography and reversed-phase conditions is therefore presented. Special attention is given to diffusion coefficients of polar compounds obtained in large percentages of acetonitrile (>90%). The effect of the buffer concentration (5-10mM ammonium acetate) on the obtained diffusion coefficients is investigated and is demonstrated to mainly influence the molecular diffusion of charged molecules. Diffusion coefficients are measured using the Taylor-Aris method and hence deduced from the peak broadening of a solute when flowing through a long open tube. The validity of the set-up employed for the measurement of the diffusion coefficients is demonstrated by ruling out the occurrence of longitudinal diffusion, secondary flow interactions and extra-column effects, while it is also shown that radial equilibration in the 15m long capillary is effective. Copyright © 2016 Elsevier B.V. All rights reserved.
Patel, Dhavalkumar Narendrabhai; Li, Lin; Kee, Chee-Leong; Ge, Xiaowei; Low, Min-Yong; Koh, Hwee-Ling
2014-01-01
The popularity of phosphodiesterase type 5 (PDE-5) enzyme inhibitors for the treatment of erectile dysfunction has led to the increase in prevalence of illicit sexual performance enhancement products. PDE-5 inhibitors, namely sildenafil, tadalafil and vardenafil, and their unapproved designer analogues are being increasingly used as adulterants in the herbal products and health supplements marketed for sexual performance enhancement. To date, more than 50 unapproved analogues of prescription PDE-5 inhibitors were found as adulterants in the literature. To avoid detection of such adulteration by standard screening protocols, the perpetrators of such illegal products are investing time and resources to synthesize exotic analogues and devise novel means for adulteration. A comprehensive review of conventional and advance analytical techniques to detect and characterize the adulterants is presented. The rapid identification and structural elucidation of unknown analogues as adulterants is greatly enhanced by the wide myriad of analytical techniques employed, including high performance liquid chromatography (HPLC), gas chromatography-mass spectrometry (GC-MS), liquid chromatography mass-spectrometry (LC-MS), nuclear magnetic resonance (NMR) spectroscopy, vibrational spectroscopy, liquid chromatography-Fourier transform ion cyclotron resonance-mass spectrometry (LC-FT-ICR-MS), liquid chromatograph-hybrid triple quadrupole linear ion trap mass spectrometer with information dependent acquisition, ultra high performance liquid chromatography-time of flight-mass spectrometry (UHPLC-TOF-MS), ion mobility spectroscopy (IMS) and immunoassay methods. The many challenges in detecting and characterizing such adulterants, and the need for concerted effort to curb adulteration in order to safe guard public safety and interest are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Valeja, Santosh G; Xiu, Lichen; Gregorich, Zachery R; Guner, Huseyin; Jin, Song; Ge, Ying
2015-01-01
To address the complexity of the proteome in mass spectrometry (MS)-based top-down proteomics, multidimensional liquid chromatography (MDLC) strategies that can effectively separate proteins with high resolution and automation are highly desirable. Although various MDLC methods that can effectively separate peptides from protein digests exist, very few MDLC strategies, primarily consisting of 2DLC, are available for intact protein separation, which is insufficient to address the complexity of the proteome. We recently demonstrated that hydrophobic interaction chromatography (HIC) utilizing a MS-compatible salt can provide high resolution separation of intact proteins for top-down proteomics. Herein, we have developed a novel 3DLC strategy by coupling HIC with ion exchange chromatography (IEC) and reverse phase chromatography (RPC) for intact protein separation. We demonstrated that a 3D (IEC-HIC-RPC) approach greatly outperformed the conventional 2D IEC-RPC approach. For the same IEC fraction (out of 35 fractions) from a crude HEK 293 cell lysate, a total of 640 proteins were identified in the 3D approach (corresponding to 201 nonredundant proteins) as compared to 47 in the 2D approach, whereas simply prolonging the gradients in RPC in the 2D approach only led to minimal improvement in protein separation and identifications. Therefore, this novel 3DLC method has great potential for effective separation of intact proteins to achieve deep proteome coverage in top-down proteomics.
Sheng, Yanghao; Zhou, Boting
2017-05-26
Therapeutic drug monitoring (TDM) is one of the most important services of clinical laboratories. Two main techniques are commonly used: the immunoassay and chromatography method. We have developed a cost-effective system of two-dimensional liquid chromatography with ultraviolet detection (2D-LC-UV) for high-throughput determination of vancomycin in human plasma that combines the automation and low start-up costs of the immunoassay with the high selectivity and sensitivity of the liquid chromatography coupled with mass spectrometric detection without incurring their disadvantages, achieving high cost-effectiveness. This 2D-LC system offers a large volume injection to provide sufficient sensitivity and uses simulated gradient peak compression technology to control peak broadening and to improve peak shape. A middle column was added to reduce the analysis cycle time and make it suitable for high-throughput routine clinical assays. The analysis cycle time was 4min and the peak width was 0.8min. Compared with other chromatographic methods that have been developed, the analysis cycle time and peak width for vancomycin was reduced significantly. The lower limit of quantification was 0.20μg/mL for vancomycin, which is the same as certain LC-MS/MS methods that have been recently developed and validated. The method is rapid, automated, and low-cost and has high selectivity and sensitivity for the quantification of vancomycin in human plasma, thus making it well-suited for use in hospital clinical laboratories. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, Chun; Wu, Qiuhua; Wu, Chunxia; Wang, Zhi
2011-01-15
A simple, rapid and environmentally friendly method has been developed for the determination of four triazole fungicides (myclobutanil, tebuconazole, triadimenol, hexaconazole) in water samples by dispersion-solidification liquid-liquid microextraction coupled with high performance liquid chromatography-diode array detection. Several variables that affect the extraction efficiencies, including the type and volume of the extraction solvent and dispersive solvent, extraction time, effect of pH and salt addition, were investigated and optimized. Under the optimum conditions, the proposed method is sensitive and shows a good linearity within a range of 0.5-200 ng mL(-1), with the correlation coefficients (r) varying from 0.9992 to 0.9998. High enrichment factors were achieved ranging from 190 to 450. The recoveries of the target analytes from water samples at spiking levels of 1.0, 5.0 and 50.0 ng mL(-1) were between 84.8% and 110.2%. The limits of detection (LODs) for the analytes were ranged in 0.06-0.1 ng mL(-1), and the relative standard deviations (RSD) varied from 3.9% to 5.7%. The proposed method has been successfully applied for the determination of the triazole fungicides in real water samples. Copyright © 2010 Elsevier B.V. All rights reserved.
Wang, Meng; Cheng, Chunsheng; Liu, Chunbo; Yang, Yaling
2018-01-01
A rapid, simple, reliable and efficient hollow fiber supported ionic liquids liquid-phase micro-extraction method (IL-HF-LPME) followed by high-performance liquid chromatography was successfully applied to the determination of four kinds of polycyclic aromatic hydrocarbons (PAHs) in milk samples. In the IL-HF-LPME method, a mixture of [OMIM]PF6 and lauric acid, in a ratio of 3:1, was immobilized in the pores of a polypropylene hollow fiber used as extraction solvent. A series of essential parameters influencing the extraction efficiency were investigated and optimized. Under the optimal conditions, the extraction equilibrium is achieved within 3 min, the good linearity was >0.9990, the limits of detection varied from 0.14 to 0.71 ng/mL, the limit of quantification values were between 0.4 and 1.8 ng/mL, and the relative standard deviations were in the range of 1.24-3.27% (n = 5). The proposed method was applied to analyze four PAHs in milk samples and recoveries were between 93.6 and 102.8%. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zeeb, Mohsen; Farahani, Hadi; Papan, Mohammad Kazem
2016-06-01
An efficient analytical method called ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography was developed for the determination of atenolol in human plasma. A hydrophobic ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was formed by the addition of a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate) to a sample solution containing an ion-pairing agent during microextraction. The analyte was extracted into the ionic liquid phase while the microextraction solvent was dispersed throughout the sample by utilizing ultrasound. The sample was then centrifuged, and the extracting phase retracted into the microsyringe and injected to liquid chromatography. After optimization, the calibration curve showed linearity in the range of 2-750 ng/mL with the regression coefficient corresponding to 0.998. The limits of detection (S/N = 3) and quantification (S/N = 10) were 0.5 and 2 ng/mL, respectively. A reasonable relative recovery range of 90-96.7% and satisfactory intra-assay (4.8-5.1%, n = 6) and interassay (5.0-5.6%, n = 9) precision along with a substantial sample clean-up demonstrated good performance of the procedure. It was applied for the determination of atenolol in human plasma after oral administration and some pharmacokinetic data were obtained. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Polymer separations by liquid interaction chromatography: principles - prospects - limitations.
Radke, Wolfgang
2014-03-28
Most heterogeneities of polymers with respect to different structural features cannot be resolved by only size exclusion chromatography (SEC), the most frequently applied mode of polymer chromatography. Instead, methods of interaction chromatography became increasingly important. However, despite the increasing applications the principles and potential of polymer interaction chromatography are still often unknown to a large number of polymer scientists. The present review will explain the principles of the different modes of polymer chromatography. Based on selected examples it will be shown which separation techniques can be successfully applied for separations with respect to the different structural features of polymers. Copyright © 2013 Elsevier B.V. All rights reserved.
Cao, Kun; Xu, Yi; Zhao, Tian-Ming; Zhang, Qing
2016-01-01
Background: Sesquiterpenoids, such as tussilagone, has effects of raising blood pressure, antiplatelet aggregation, and anti-inflammation activities, which is regarded as index compound for quality control of Tussilago farfara L. Objective: This study was aimed to obtain an effective method for fast isolation of sesquiterpenoids from T. farfara L. by high-speed counter-current chromatography (HSCCC). Materials and Methods: A solvent optimization method for HSCCC was presented, i.e., the separation factors of compounds after the K values of solvent system should be investigated. Results: A ternary solvent system of n-hexane:methanol:water (5:8:2, v/v/v) was selected and applied for the HSCCC, and 56 mg of tussilagone (2) was isolated from T. farfara L., along with two other sesquiterpenoids 5.6 mg of 2,2-dimethyl-6-acetylchromanone (1) and 22 mg of 14-acetoxy-7 β-(3’-ethyl cis-crotonoyloxy)-lα-(2’-methylbutyryloxy)-notonipetranone (3) by HSCCC with high purities. Their chemical structures were elucidated by liquid chromatography-mass spectrometry and nuclear magnetic resonance experiments. Conclusion: These results offered an efficient strategy for preparation of potentially health-relevant phytochemicals from T. farfara L., which might be used for further chemical research and pharmacological studies by preparative HSCCC. SUMMARY The real separation efficiency has been verified by analytical HSCCC.A solvent optimization method for HSCCC was presented and applied to separate and prepare active compounds.A method for rapid and effective separation of target compound Tussilagone with high yield and purity from the flower buds of Tussilago farfara.Two other compounds 2,2-Dimethyl-6-acetylchromanone and 14-acetoxy-7β-(3’-ethyl cis-crotonoyloxy) -lα- (2’-methylbutyryloxy). notonipetranone hasbeen obtained with high purities from flower buds of Tussilago farfara. Abbreviations used: HSCCC: High-Speed Counter-Current Chromatography; LC-MS: Liquid Chromatograph-Mass Spectrometer; NMR: Nuclear Magnetic Resonance; TCM: Traditional Chinese Medicine; HPLC: High Performance Liquid Chromatography; ESI-MS: Electrospray Ionization Mass Spectrometry; PE: petroleum ether PMID:27867270
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wittmann, S.; Decsy, Z.; Regensperger, S.
1984-01-01
The separation and determination of groups of alkylphenols with C/sub 15/-C/sub 33/ isoalkane chains by gas chromatography, elution liquid chromatography, and gel permeation chromatography are described. Paraffinic hydrocarbons, monoalkylphenols, dialkylphenols, and bis(hydroxyphenyl)alkanes were identified in industrial alkylphenols by mass spectrometry. 7 references, 3 figures, 2 tables.
[Simultaneous determination of ochratoxin A, B and citrinin in foods by HPLC-FL and LC/MS/MS].
Tabata, Setsuko; Iida, Kenji; Kimura, Keisuke; Iwasaki, Yumiko; Nakazato, Mitsuo; Kamata, Kunihiro; Hirokado, Masako
2008-04-01
Methods using high-performance liquid chromatography with fluorescence detection (HPLC-FL) and using liquid chromatography with tandem mass spectrometry (LC/MS/MS) were developed for simultaneous determination of ochratoxin A (OTA), ochratoxin B (OTB) and citrinin (CIT) in cereal, fruit, and coffee products. The samples were extracted with ethyl acetate under an acidic condition, and then cleaned up with liquid-liquid separation. The test solutions were analyzed by reverse-phase HPLC-FL and LC/MS/MS. Mass spectral acquisition was performed in positive ion mode by applying multiple reaction monitoring. The performances of both detectors were almost equivalent. The recoveries of OTA and OTB were 87-111%, and that of CIT were 70-88%. The limits of quantification (S/N> or =10) of OTA, OTB and CIT was 0.1 mug/kg or less. These methods were considered to be useful for the determination of the three mycotoxins at low levels (0.1 microg/kg).
Wang, Jiang; Jiang, Yao; Wang, Yingwu; Zhao, Xia; Cui, Yimin; Gu, Jingkai
2007-05-09
A simple, sensitive and specific liquid chromatography/tandem mass spectrometry method for the quantitation of aildenafil, a new phosphodiesterase V inhibitor, in human plasma is presented. The analyte and internal standard, sildenafil, were extracted by a one-step liquid-liquid extraction in alkaline conditions and separated on a C(18) column using ammonia:10mM ammonium acetate buffer:methanol (0.1:15:85, v/v/v) as the mobile phase. The detection by an API 4000 triple quadrupole mass spectrometer in multiple-reaction monitoring mode was completed within 2.5 min. The calibration curve exhibited a linear dynamic range of 0.05-100 ng/ml with a 10 pg/ml limit of detection. The intra- and inter-day precisions measured as relative standard deviation were within 8.04% and 5.72%, respectively. This method has been used in a pharmacokinetic study of aildenafil in healthy male volunteers each given an oral administration of one of the three dosages.
Liu, Ai-Hua; Guo, Hui; Ye, Min; Lin, Yan-Hua; Sun, Jiang-Hao; Xu, Man; Guo, De-An
2007-08-17
By using HPLC-diode array detection-electrospray ion trap tandem mass spectrometry (HPLC-DAD-ESI-MS(n)) in negative ion mode, we have analyzed the fragmentation pathways of 11 phenolic acids which were isolated from Danshen. Then the extract of Danshen was analyzed, and a total of 42 phenolic acids, including sixteen new minor constituents, were identified or tentatively identified for the first time. A new solid-phase extraction (SPE) method, new HPLC separation method, new liquid chromatography (LC)-MS and LC-MS(n) (n=3-5) data and proposed fragmentation pathways, LC retention time for phenolic acids are reported.
[Determination of doping in human urine by gas chromatography-high resolution mass spectrometry].
Xing, Yan-Yi; Liu, Xin; Zhang, Yu-Mei; Wang, Xiao-Bing; Xu, You-Xuan
2012-12-01
A method was evaluated for determination of twenty-one doping (including nandrolone, boldenone and methandienone) in human urine by gas chromatography-high resolution mass spectrometry. Samples were prepared by liquid-liquid extraction, concentrated, TMS derivatization and limit of detection at ng x mL(-1) by MID/GC/HRMS. According to the code of the World Anti-Doping Agency (WADA), precision and recoveries of the procedure were evaluated by replicate analysis (n = 6), the recoveries in the range of 66%-103%, with the RSD below 10.0%. The precision within the day of the method with three different concentrations was also determined RSD were less than 9.5%, 10.0% and 9.7%.
Thera, Jennifer C; Kidd, Karen A; Dodge-Lynch, M Elaine; Bertolo, Robert F
2017-12-15
We examined the performance of an ultra-high performance liquid chromatography method to quantify protein-bound sulphur amino acids in zooplankton. Both cysteic acid and methionine sulfone were linear from 5 to 250 pmol (r 2 = 0.99), with a method detection limit of 13 pmol and 9 pmol, respectively. Although there was no matrix effect on linearity, adjacent peaks and co-eluting noise from the invertebrate proteins increased the detection limits when compared to common standards. Overall, performance characteristics were reproducible and accurate, and provide a means for quantifying sulphur amino acids in aquatic invertebrates, an understudied group. Copyright © 2017 Elsevier Inc. All rights reserved.
Miksík, Ivan; Mikulíková, Katerina; Pácha, Jirí; Kucka, Marek; Deyl, Zdenek
2004-02-05
A high-performance liquid chromatography-atmospheric pressure ionization-electrospray ionization mass spectrometry (HPLC-API-ESI-MS) method was developed for the analysis of steroids in a study of steroid-converting enzymes. Separations ware done on a Zorbax Eclipse XDB-C18 column (eluted with a linear methanol-water-acetic acid gradient) and identification of the steroids involved was done by API-ESI-MS using positive ion mode and extracted ion analysis. The applicability of the present method for studying steroid metabolism was proven in assaying two steroid-converting enzymes (20beta-hydroxysteroid dehydrogenase and 11beta-hydroxysteroid dehydrogenase) in various biological samples (rat and chicken intestine, chicken oviduct).
Li, Hui; Lu, Dingqiang; Liu, Weimin
2004-05-01
A method for determining glycyrrhizinic acid in the biotransformation system by reversed-phase high performance liquid chromatography (RP-HPLC) was developed. The HPLC conditions were as follows: Hypersil C18 column (4.6 mm i.d. x 250 mm, 5 microm) with a mixture of methanol-water-acetic acid (70:30:1, v/v) as the mobile phase; flow rate at 1.0 mL/min; and UV detection at 254 nm. The linear range of glycyrrhizinic acid was 0.2-20 microg. The recoveries were 98%-103% with relative standard deviations between 0.16% and 1.58% (n = 3). The method is simple, rapid and accurate for determining glycyrrhizinic acid.
Bielawski, D; Ostrea, E; Posecion, N; Corrion, M; Seagraves, J
2005-01-01
A solid phase extraction method was developed to isolate multiple classes of parent pesticides from meconium. A methanolic/hydrochloric acid methyl ester derivatization with liquid-liquid extraction technique was also developed for the analysis of metabolites. Identification and quantitation was by electron impact gas chromatography-mass spectrometry. For the parent compounds and metabolites, recoveries in spiked meconium ranged between 72-109%, with coefficients of variation ranging from 1.55-16.92% and limits of detection between 0.01-4.15 μg g(-1). Meconium samples obtained from infants in the Philippines were assayed using these methods, and propoxur, cypermethrin, pretilachlor, malathion, 4,4'-dichlorodiphenyltrichloroethylene, bioallethrin, and cyfluthrin were detected.
Charlton, Andrew J A; Stuckey, Vicki; Sykes, Mark D
2009-06-01
An analytical method was developed to determine the phenoxyacid herbicides 2,4-D, MCPA and mecoprop in kidney tissue from animals where poisoning is suspected. Samples were Soxhlet extracted using diethyl ether and the extracts cleaned-up using anion exchange solid phase extraction cartridges. Analysis was performed using liquid chromatography with negative-ion electrospray tandem mass spectrometry (LC-MS/MS). The method was evaluated by analysing control kidney samples fortified at 1 and 5 mg/kg. Mean recoveries ranged from 82 to 93% with relative standard deviations from 3.2 to 19%. The limit of detection was estimated to be 0.02 mg/kg.
Fuels characterization studies. [jet fuels
NASA Technical Reports Server (NTRS)
Seng, G. T.; Antoine, A. C.; Flores, F. J.
1980-01-01
Current analytical techniques used in the characterization of broadened properties fuels are briefly described. Included are liquid chromatography, gas chromatography, and nuclear magnetic resonance spectroscopy. High performance liquid chromatographic ground-type methods development is being approached from several directions, including aromatic fraction standards development and the elimination of standards through removal or partial removal of the alkene and aromatic fractions or through the use of whole fuel refractive index values. More sensitive methods for alkene determinations using an ultraviolet-visible detector are also being pursued. Some of the more successful gas chromatographic physical property determinations for petroleum derived fuels are the distillation curve (simulated distillation), heat of combustion, hydrogen content, API gravity, viscosity, flash point, and (to a lesser extent) freezing point.
Liu, Aifeng; Shen, Zhaoshuang; Tian, Yong; Shi, Rongguang; Liu, Yi; Zhao, Zongshan; Xian, Mo
2017-12-01
As brominated flame retardants (BFRs), tetrabromobisphenol A/S (TBBPA/S) and their derivatives have raised wide concerns owing to their widely usage, distributions and adverse effects on human health, thus monitoring these BFRs was urgently needed. In this study, a rapid and cost-effective method based on thin-layer chromatography (TLC) sample pre-treatment coupled with high performance liquid chromatography-diode array detector (HPLC-DAD) (UV=214nm) was developed for determining TBBPA/S and their derivatives in soils, including TBBPA, TBBPA bis(allyl ether) (TBBPA-BAE), TBBPA bis(2,3-dibromopropyl ether) (TBBPA-BDBPE), TBBPS bis(allyl ether) (TBBPS-BAE) and TBBPS bis(2,3-dibromopropyl ether) (TBBPS-BDBPE). The method detection limits (MDLs) and the method quantification limits (MQLs) for these BFRs ranged from 0.023 to 0.087μgg -1 dw and 0.076-0.29μgg -1 dw, respectively. The recoveries were 41-108% and both RSD of repeatability and intermediate precision were less than 11%. The developed method presented good performance for analyzing natural soil samples collected from BFRs industrial park, suggesting its great application potential for monitoring environmental TBBPA/S and their derivatives. Copyright © 2017 Elsevier B.V. All rights reserved.
Asati, Ankita; Satyanarayana, G N V; Panchal, Smita; Thakur, Ravindra Singh; Ansari, Nasreen G; Patel, Devendra K
2017-08-04
A sensitive, rapid and efficient ionic liquid-based vortex assisted liquid-liquid microextraction (IL-VALLME) with Liquid Chromatography Mass spectrometry (LC-MS/MS) method is proposed for the determination of bisphenols in thermal paper. Extraction factors were systematically optimized by response surface methodology. Experimental factors showing significant effects on the analytical responses were evaluated using design of experiment. The limit of detection for Bisphenol-A (BPA) and Bisphenol-S (BPS) in thermal paper were 1.25 and 0.93μgkg -1 respectively. The dynamic linearity range for BPA was between 4 and 100μgkg -1 and the determination of coefficient (R 2 ) was 0.996. The values of the same parameters were 3-100μgkg -1 and 0.998 for BPS. The extraction recoveries of BPA and BPS in thermal paper were 101% and 99%. Percent relative standard deviation (% RSD) for matrix effect and matrix match effects were not more than 10%, for both bisphenols. The proposed method uses a statistical approach for the analysis of bisphenols in environmental samples, and is easy, rapid, requires minimum organic solvents and efficient. Copyright © 2017 Elsevier B.V. All rights reserved.
Penney, Lisa; Smith, Anderson; Coates, Brent; Wijewickreme, Arosha
2005-01-01
A new liquid chromatography/mass spectrometry (LC/MS) method is presented for the determination of chloramphenicol (CAP) residues in milk, eggs, chicken muscle and liver, and beef muscle and kidney. CAP is extracted from the samples with acetonitrile and defatted with hexane. The acetonitrile extracts are then evaporated, and residues are reconstituted in 10mM ammonium acetate--acetonitrile mobile phase and injected into the LC system. CAP is determined by reversed-phase chromatography using an Inertsil ODS-2 column and MS detection with negative ion electrospray ionization. Calibration curves were linear between 0.5-5.0 ng/g for all matrixes studied. The relative standard deviations for measurements by this method were generally <12%, and average recoveries ranged from 80 to 120%, depending on the matrix involved. The method detection limits of CAP ranged from 0.2 to 0.6 ng/g, which are comparable to previously reported results. The proposed method is rapid, simple, and specific, allowing a single analyst to easily prepare over 40 samples in a regular working day.
NASA Astrophysics Data System (ADS)
Zhang, Xiang; Wang, Mingchao; Li, Li; Yin, Dali
2017-03-01
Asymmetric reactions often need to be evaluated during the synthesis of chiral compounds. However, traditional evaluation methods require the isolation of the individual enantiomer, which is tedious and time-consuming. Thus, it is desirable to develop simple, practical online detection methods. We developed a method based on high-performance liquid chromatography-electronic circular dichroism (HPLC-ECD) that simultaneously analyzes the material conversion ratio and absolute optical purity of each enantiomer. In particular, only a reverse-phase C18 column instead of a chiral column is required in our method because the ECD measurement provides a g-factor that describes the ratio of each enantiomer in the mixtures. We used our method to analyze the asymmetric hydrosilylation of β-enamino esters, and we discussed the advantage, feasibility, and effectiveness of this new methodology.
Matrix effects in pesticide multi-residue analysis by liquid chromatography-mass spectrometry.
Kruve, Anneli; Künnapas, Allan; Herodes, Koit; Leito, Ivo
2008-04-11
Three sample preparation methods: Luke method (AOAC 985.22), QuEChERS (quick, easy, cheap, effective, rugged and safe) and matrix solid-phase dispersion (MSPD) were applied to different fruits and vegetables for analysis of 14 pesticide residues by high-performance liquid chromatography with electrospray ionization-mass spectrometry (HPLC/ESI/MS). Matrix effect, recovery and process efficiency of the sample preparation methods applied to different fruits and vegetables were compared. The Luke method was found to produce least matrix effect. On an average the best recoveries were obtained with the QuEChERS method. MSPD gave unsatisfactory recoveries for some basic pesticide residues. Comparison of matrix effects for different apple varieties showed high variability for some residues. It was demonstrated that the amount of co-extracting compounds that cause ionization suppression of aldicarb depends on the apple variety as well as on the sample preparation method employed.
Eom, Min Rye; Weon, Jin Bae; Jung, Youn Sik; Ryu, Ga Hee; Yang, Woo Seung; Ma, Choong Je
2017-01-01
Background: Reynoutria sachalinensis is a well-known and used herbal medicine to treatment of arthralgia, jaundice, amenorrhea, coughs, carbuncles, and sores. Objective: We have developed high-performance liquid chromatography analysis method for simultaneous determination of isolated four compounds, campesterol, emodin8-O-β-D-glucopyranoside, quercetin, and isoquercitrin from R. sachalinensis is. Materials and Methods: The four compounds were separated on Shiseido C18 column (S-5 μm, 4.6 mm I.D. ×250 mm) at a column temperature of 25°C. The mobile phase composed of water and methanol with gradient elution system, and flow rate is 1.0 ml/min. The detection wavelength was set at 205 nm. Results: Validation of this analytical method was evaluated by linearity, precision, and accuracy test. This established method had good linearity (R2 > 0.997). The relative standard deviation values of intra- and inter-day testing were indicated that <2%, and accuracy is 91.66%–103.31% at intraday and 91.69%–103.31% at intraday. The results of recovery test were 92.60%–108.99%. Conclusion: In these results, developed method was accurate and reliable to the quality evaluation of campesterol, emodin 8-O-β-D-glucopyranoside, quercetin, and isoquercitrin isolated from R. sachalinensis. SUMMARY We have developed high-performance liquid analysis method for simultaneous determination of 4 compounds of Reynoutria sachalinensis. Abbreviations used: HPLC: High-performance liquid chromatography, DAD: Diode array detector, LOD: Limit of detection, LOQ: Limit of quantitation, ICH: International Conference on Harmonisation. PMID:28808389
Li, Austin C; Li, Yinghe; Guirguis, Micheal S; Caldwell, Robert G; Shou, Wilson Z
2007-01-04
A new analytical method is described here for the quantitation of anti-inflammatory drug cyclosporin A (CyA) in monkey and rat plasma. The method used tetrahydrofuran (THF)-water mobile phases to elute the analyte and internal standard, cyclosporin C (CyC). The gradient mobile phase program successfully eluted CyA into a sharp peak and therefore improved resolution between the analyte and possible interfering materials compared with previously reported analytical approaches, where CyA was eluted as a broad peak due to the rapid conversion between different conformers. The sharp peak resulted from this method facilitated the quantitative calculation as multiple smoothing and large number of bunching factors were not necessary. The chromatography in the new method was performed at 30 degrees C instead of 65-70 degrees C as reported previously. Other advantages of the method included simple and fast sample extraction-protein precipitation, direct injection of the extraction supernatant to column for analysis, and elimination of evaporation and reconstitution steps, which were needed in solid phase extraction or liquid-liquid extraction reported before. This method is amenable to high-throughput analysis with a total chromatographic run time of 3 min. This approach has been verified as sensitive, linear (0.977-4000 ng/mL), accurate and precise for the quantitation of CyA in monkey and rat plasma. However, compared with the usage of conventional mobile phases, the only drawback of this approach was the reduced detection response from the mass spectrometer that was possibly caused by poor desolvation in the ionization source. This is the first report to demonstrate the advantages of using THF-water mobile phases to elute CyA in liquid chromatography.
Asati, Ankita; Satyanarayana, G N V; Patel, Devendra K
2017-09-01
Two low density organic solvents based liquid-liquid microextraction methods, namely Vortex assisted liquid-liquid microextraction based on solidification of floating organic droplet (VALLME-SFO) and Dispersive liquid-liquid microextraction based on solidification of floating organic droplet(DLLME-SFO) have been compared for the determination of multiclass analytes (pesticides, plasticizers, pharmaceuticals and personal care products) in river water samples by using liquid chromatography tandem mass spectrometry (LC-MS/MS). The effect of various experimental parameters on the efficiency of the two methods and their optimum values were studied with the aid of Central Composite Design (CCD) and Response Surface Methodology(RSM). Under optimal conditions, VALLME-SFO was validated in terms of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery for which the respective values were (0.011-0.219ngmL -1 ), (0.035-0.723ngmL -1 ), (0.050-0.500ngmL -1 ), (R 2 =0.992-0.999), (40-56), (80-106%). However, when the DLLME-SFO method was validated under optimal conditions, the range of values of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery were (0.025-0.377ngmL -1 ), (0.083-1.256ngmL -1 ), (0.100-1.000ngmL -1 ), (R 2 =0.990-0.999), (35-49), (69-98%) respectively. Interday and intraday precisions were calculated as percent relative standard deviation (%RSD) and the values were ≤15% for VALLME-SFO and DLLME-SFO methods. Both methods were successfully applied for determining multiclass analytes in river water samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Kwok, Karen Y; Choi, Timmy L S; Kwok, Wai Him; Wong, Jenny K Y; Wan, Terence S M
2017-04-14
Anabolic and androgenic steroids (AASs) are a class of prohibited substances banned in horseracing at all times. The common approach for controlling the misuse of AASs in equine sports is by detecting the presence of AASs and/or their metabolites in urine and blood samples using gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). This approach, however, often falls short as the duration of effect for many AASs are longer than their detection time in both urine and blood. As a result, there is a high risk that such AASs could escape detection in their official race-day samples although they may have been used during the long period of training. Hair analysis, on the other hand, can afford significantly longer detection windows. In addition, the identification of synthetic ester derivatives of AASs in hair, particularly for the endogenous ones, can provide unequivocal proof of their exogenous origin. This paper describes the development of a sensitive method (at sub to low parts-per-billion or ppb levels) for detecting 48 AASs and/or their esters in horse hair using ultra-high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS). Decontaminated horse hair was pulverised and subjected to in-situ liquid-liquid extraction in a mixture of hexane - ethyl acetate (7:3, v/v) and phosphate buffer (0.1M, pH 9.5), followed by additional clean-up using mixed-mode solid-phase extraction. The final extract was analysed using UHPLC-HRMS in the positive electrospray ionisation (ESI) mode with both full scan and parallel reaction monitoring (PRM). This method was validated for qualitative identification purposes. Validation data, including method specificity, method sensitivity, extraction recovery, method precision and matrix effect are presented. Method applicability was demonstrated by the successful detection and confirmation of testosterone propionate in a referee hair sample. To our knowledge, this was the first report of a comprehensive screening method for detecting as many as 48 AASs and/or their esters in horse hair. Moreover, retrospective analysis of non-targeted AASs and/or their esters was made feasible by re-examining the full scan UHPLC-HRMS data acquired. Copyright © 2017 Elsevier B.V. All rights reserved.
Makoś, Patrycja; Fernandes, André; Boczkaj, Grzegorz
2018-06-01
We present a new method for simultaneous determination of 22 monoaromatic and polycyclic aromatic hydrocarbons in postoxidative effluents from the production of petroleum bitumen using dispersive liquid-liquid microextraction coupled to gas chromatography and mass spectrometry. The eight extraction parameters including the type and volume of extraction and disperser solvent, pH, salting out effect, extraction, and centrifugation time were optimized. The low detection limit ranging from 0.36 to 28 μg/L, limit of quantitation (1.1-84 μg/L), good reproducibility, and wide linear ranges, as well as the recoveries ranging from 71.74 to 114.67% revealed that the new method allows the determination of aromatic hydrocarbons at low concentration levels in industrial effluents having a very complex composition. The developed method was applied to the determination of content of mono- and polycyclic aromatic hydrocarbons in samples of raw postoxidative effluents in which 15 compounds were identified at concentrations ranging from 1.21 to 1017.0 μg/L as well as in effluents after chemical treatment. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bade, Richard; White, Jason M; Gerber, Cobus
2018-01-01
The combination of qualitative and quantitative bimonthly analysis of pharmaceuticals and illicit drugs using liquid chromatography coupled to mass spectrometry is presented. A liquid chromatography-quadrupole time of flight instrument equipped with Sequential Window Acquisition of all THeoretical fragment-ion spectra (SWATH) was used to qualitatively screen 346 compounds in influent wastewater from two wastewater treatment plants in South Australia over a 14-month period. A total of 100 compounds were confirmed and/or detected using this strategy, with 61 confirmed in all samples including antidepressants (amitriptyline, dothiepin, doxepin), antipsychotics (amisulpride, clozapine), illicit drugs (cocaine, methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA)), and known drug adulterants (lidocaine and tetramisole). A subset of these compounds was also included in a quantitative method, analyzed on a liquid chromatography-triple quadrupole mass spectrometer. The use of illicit stimulants (methamphetamine) showed a clear decrease, levels of opioid analgesics (morphine and methadone) remained relatively stable, while the use of new psychoactive substances (methylenedioxypyrovalerone (MDPV) and Alpha PVP) varied with no visible trend. This work demonstrates the value that high-frequency sampling combined with quantitative and qualitative analysis can deliver. Graphical abstract Temporal analysis of licit and illicit drugs in South Australia.
Rigol, A; Latorre, A; Lacorte, S; Barceló, D
2002-07-19
Three analytical methods were developed for the determination of toxic compounds in recirculating waters of a paper-recycling industry. Three main groups of compounds were considered: (i) wood extractives originated from the raw material; (ii) biocides added during the production process and (iii) surfactants and other adjuvants present in the formulates of these biocides. Wood extractives considered in this study included fatty and resin acids. They were analysed by liquid-liquid extraction using methyl tert.-butyl ether, followed by gas chromatography-mass spectrometry for previous formation of the respective trimethylsilyl esters. Water samples were also extracted with Oasis HLB (copolymer [poly(divinylbenzene-co-N-vinylpyrrolidone]) solid-phase extraction cartridges of 60 mg and analysed by liquid chromatography-electrospray mass spectrometry for the determination of additives and biocides. Using these two approaches levels up to 15 mg/l for total resin and fatty acids, 5 mg/l for alkylbenzene sulfonates and 2-(thiocyanomethylthio)benzotiazol, 100 microg/l for bisphenol A and 2,2-dibromo-3-nitrilepropionamide, and 300 microg/l for nonylphenol ethoxycarboxylate were detected in process waters at different production treatment stages. These levels are of relevance since poor water quality affects the paper-recycling process, the primary water treatment process and eventually, the environmental water quality.
Liang, Pei; Wang, Fang; Wan, Qin
2013-02-15
A highly efficient and environmentally friendly sample preparation method termed ionic liquid-based ultrasound-assisted emulsification microextraction (IL-USAEME) combined with high performance liquid chromatography has been developed for the determination of four fungicides (azoxystrobin, diethofencarb, pyrimethanil and kresoxim-methyl) in water samples. In this novel approach, ionic liquid (IL) was used as extraction solvent in place of the organic solvent used in conventional USAEME assay, and there is no need for using organic dispersive solvent which is typically required in the common dispersive liquid-liquid microextraction method. Various parameters that affect the extraction efficiency, such as the kind and volume of IL, ultrasound emulsification time, extraction temperature and salt addition were investigated and optimized. Under the optimum extraction condition, the linearities of calibration curves were in the range from 3 to 5000 ng mL(-1) for target analytes with the correlation coefficient higher than 0.9992. The enrichment factors and the limits of detection were in the range of 88-137 and 0.73-2.2 ng mL(-1), depending on the analytes. The environmental water samples were successfully analyzed using the proposed method, and the relative recoveries at fortified levels of 50 and 100 ng mL(-1) were in the range of 83.9%-116.2%. Copyright © 2012 Elsevier B.V. All rights reserved.
Pacheco-Fernández, Idaira; Herrera-Fuentes, Ariadna; Delgado, Bárbara; Pino, Verónica; Ayala, Juan H; Afonso, Ana M
2017-03-01
The environmental monitoring of trihalomethanes (THMs) has been performed by setting up a dispersive liquid-liquid microextraction method in combination with gas chromatography (GC)-mass spectrometry (MS). The optimized method only requires ∼26 µL of decanol as extractant solvent, dissolved in ∼1 mL of acetone (dispersive solvent) for 5 mL of the environmental water containing THMs. The mixture is then subjected to vortex for 1 min and then centrifuged for 2 min at 3500 rpm. The microdroplet containing the extracted THMs is then sampled with a micro-syringe, and injected (1 µL) in the GC-MS. The method is characterized for being fast (3 min for the entire sample preparation step) and environmentally friendly (low amounts of solvents required, being all non-chlorinated), and also for getting average relative recoveries of 90.2-106% in tap waters; relative standard deviation values always lower than 11%; average enrichment factors of 48-49; and detection limits down to 0.7 µg·L-1. Several waters: tap waters, pool waters, and wastewaters were successfully analyzed with the method proposed. Furthermore, the method was used to monitor the formation of THMs in wastewaters when different chlorination parameters, namely temperature and pH, were varied.
Filip, Katarzyna; Grynkiewicz, Grzegorz; Gruza, Mariusz; Jatczak, Kamil; Zagrodzki, Bogdan
2014-01-01
Escin, a complex mixture of pentacyclic triterpene saponins obtained from horse chestnut seeds extract (HCSE; Aesculus hippocastanum L.), constitutes a traditional herbal active substance of preparations (drugs) used for a treatment of chronic venous insufficiency and capillary blood vessel leakage. A new approach to exploitation of pharmacological potential of this saponin complex has been recently proposed, in which the β-escin mixture is perceived as a source of a hitherto unavailable raw material, pentacyclic triterpene aglycone-protoescigenin. Although many liquid chromatography methods are described in the literature for saponins determination, analysis of protoescigenin is barely mentioned. In this work, a new ultra-high performance liquid chromatography (UHPLC) method developed for protoescigenin quantification has been described. CAD (charged aerosol detection), as a relatively new detection method based on aerosol charging, has been applied in this method as an alternative to ultraviolet (UV) detection. The influence of individual parameters on CAD response and sensitivity was studied. The detection was performed using CAD and UV (200 nm) simultaneously and the results were compared with reference to linearity, accuracy, precision and limit of detection.
Wu, Wenying; Chen, Yu; Wang, Binjie; Sun, Xiaoyang; Guo, Ping; Chen, Xiaohui
2017-08-01
Baidianling Capsule, which is made from 16 Chinese herbs, has been widely used for treating vitiligo clinically. In this study, the sensitive and rapid method has been developed for the analysis of chemical components in Baidianling Capsule by gas chromatography-mass spectrometry in combination with retention indices and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Firstly, a total of 110 potential volatile compounds obtained from different extraction procedures including alkanes, alkenes, alkynes, ketones, ethers, aldehydes, alcohols, phenols, organic acids, esters, furans, pyrrole, acid amides, heterocycles, and oxides were detected from Baidianling Capsule by gas chromatography-mass spectrometry, of which 75 were identified by mass spectrometry in combination with the retention index. Then, a total of 124 components were tentatively identified by high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Fifteen constituents from Baidianling Capsule were accurately identified by comparing the retention times with those of reference compounds, others were identified by comparing the retention times and mass spectrometry data, as well as retrieving the reference literature. This study provides a practical strategy for rapidly screening and identifying the multiple constituents of a complex traditional Chinese medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Werner, Justyna
2016-04-01
Task-specific ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction was used for the preconcentration of cadmium(II), cobalt(II), and lead(II) ions in tea samples, which were subsequently analyzed by liquid chromatography with UV detection. The proposed method of preconcentration is free of volatile organic compounds, which are often used as extractants and dispersing solvents in classic techniques of microextraction. A task-specific ionic liquid trioctylmethylammonium thiosalicylate was used as an extractant and a chelating agent. Ultrasound was used to disperse the ionic liquid. After microextraction, the phases were separated by centrifugation, and the ionic liquid phase was solubilized in methanol and directly injected into the liquid chromatograph. Selected microextraction parameters, such as the volume of ionic liquid, the pH of the sample, the duration of ultrasound treatment, the speed and time of centrifugation, and the effect of ionic strength, were optimized. Under optimal conditions an enrichment factor of 200 was obtained for each analyte. The limits of detection were 0.002 mg/kg for Cd(II), 0.009 mg/kg for Co(II), and 0.013 mg/kg for Pb(II). The accuracy of the proposed method was evaluated by an analysis of the Certified Reference Materials (INCT-TL-1, INCT-MPH-2) with the recovery values in the range of 90-104%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chen, Tao; Li, Hongmei; Zou, Denglang; Liu, Yongling; Chen, Chen; Zhou, Guoying; Li, Yulin
2016-08-01
Anthraquinone glycosides, such as chrysophanol 1-O-β-d-glucoside, chrysophanol 8-O-β-d-glucoside, and physion 8-O-β-d-glucoside, are the accepted important active components of Rheum tanguticum Maxim. ex Balf. due to their pharmacological properties: antifungal, antimicrobial, cytotoxic, and antioxidant activities. However, an effective method for the separation of the above-mentioned anthraquinone glycosides from this herb is not currently available. Especially, greater difficulty existed in the separation of the two isomers chrysophanol 1-O-β-d-glucoside and chrysophanol 8-O-β-d-glucoside. This study demonstrated an efficient strategy based on preparative high-performance liquid chromatography and high-speed countercurrent chromatography for the separation of the above-mentioned anthraquinone glycosides from Rheum tanguticum Maxim.ex Balf. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sadeghi, Ramezan; Kobarfard, Farzad; Yazdanpanah, Hassan; Eslamizad, Samira; Bayate, Mitra
2016-01-01
Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and water for injection. Dispersive liquid-liquid microextraction procedure combined with gas chromatography-mass spectrometry was used for the extraction and determination of PAHs in the samples. Under the optimized conditions, the range of extraction recoveries and relative standard deviations (RSDs) of PAHs in water using internal standard (anthracene-d10) were in the range of 71-90% and 4-16%, respectively. Limit of detection for different PAHs were between 0.03 and 0.1 ngmL-1. The concentration of PAHs in all tap water as well as water for injection samples were lower than the limit of quantification of PAHs. This is the first study addressing the occurrence of PAHs in water for injection samples in Iran using dispersive liquid-liquid micro extraction procedure combined with gas chromatography-mass spectrometry. PMID:27642318
Triebl, Alexander; Trötzmüller, Martin; Hartler, Jürgen; Stojakovic, Tatjana; Köfeler, Harald C
2018-01-01
An improved approach for selective and sensitive identification and quantitation of lipid molecular species using reversed phase chromatography coupled to high resolution mass spectrometry was developed. The method is applicable to a wide variety of biological matrices using a simple liquid-liquid extraction procedure. Together, this approach combines three selectivity criteria: Reversed phase chromatography separates lipids according to their acyl chain length and degree of unsaturation and is capable of resolving positional isomers of lysophospholipids, as well as structural isomers of diacyl phospholipids and glycerolipids. Orbitrap mass spectrometry delivers the elemental composition of both positive and negative ions with high mass accuracy. Finally, automatically generated tandem mass spectra provide structural insight into numerous glycerolipids, phospholipids, and sphingolipids within a single run. Method validation resulted in a linearity range of more than four orders of magnitude, good values for accuracy and precision at biologically relevant concentration levels, and limits of quantitation of a few femtomoles on column. Hundreds of lipid molecular species were detected and quantified in three different biological matrices, which cover well the wide variety and complexity of various model organisms in lipidomic research. Together with a reliable software package, this method is a prime choice for global lipidomic analysis of even the most complex biological samples. PMID:28415015
Zeng, Dongping; Shen, Xiangguang; He, Limin; Ding, Huanzhong; Tang, Youzhi; Sun, Yongxue; Fang, Binghu; Zeng, Zhenling
2012-06-01
A rapid liquid chromatography tandem mass spectrometric method was developed for the simultaneous determination of mequindox and its five metabolites (2-isoethanol mequindox, 2-isoethanol 1-desoxymequindox, 1-desoxymequindox, 1,4-bisdesoxymequindox, and 2-isoethanol bisdesoxymequindox) in porcine muscle, liver, and kidney, fulfilling confirmation criteria with two transitions for each compound with acceptable relative ion intensities. The method involved acid hydrolysis, purification by solid-phase extraction, and subsequent analysis with liquid chromatography tandem mass spectrometry using electrospray ionization operated in positive polarity with a total run time of 15 min. The decision limit values of five analytes in porcine tissues ranged from 0.6 to 2.9 μg/kg, and the detection capability values ranged from 1.2 to 5.7 μg/kg. The results of the inter-day study, which was performed by fortifying porcine muscle (2, 4, and 8 μg/kg), liver, and kidney (10, 20, and 40 μg/kg) samples on three separate days, showed that the accuracy of the method for the various analytes ranged between 75.3 and 107.2% with relative standard deviation less than 12% for each analyte. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Zhou, Mingqiong; Peng, Jingdong; He, Rongxing; He, Yuting; Zhang, Jing; Li, Aiping
2015-02-01
A reliable and versatile high performance liquid chromatography coupled with resonance Rayleigh scattering method was established for the determination of three fluoroquinolones, including levofloxacin, norfloxacin and enrofloxacin in water sample and human urine sample. In pH 4.4-4.6 Britton-Robinson buffer medium, the fluoroquinolones separated by high performance liquid chromatography could react with erythrosine to form 1:1 ion-association complexes, which could make contributions to the great enhancement of RRS. The resonance Rayleigh scattering signal was recorded at λex = λem = 330 nm. The resonance Rayleigh scattering spectral characteristics of the drugs and the experimental conditions such as pH, detection wavelength, erythrosine concentration, flow rate, the length of reaction tube were studied. Quantum chemistry calculation, Fourier transform infrared spectroscopy and absorption spectroscopy were used to discuss the reaction mechanism. The recoveries of samples added standard ranged from 97.53% to 102.00%, and the relative standard deviation was below 4.64%. The limit of detection (S/N = 3) of 0.05-0.12 μg mL-1 was reached, and the linear regression coefficients were all above 0.999. The proposed method was proved as a simple, low cost and high sensitivity method.
Sha, Ou; Zhu, Xiashi; Feng, Yanli; Ma, Weixing
2015-05-01
A rapid and effective method of aqueous two-phase systems based on ionic liquid microextraction for the simultaneous determination of five synthetic food colourants (tartrazine, sunset yellow, amaranth, ponceau 4R and brilliant blue) in food samples was established. High-performance liquid chromatography coupled with an ultraviolet detector of variable wavelength was used for the determinations. 1-alkyl-3-methylimidazolium bromide was selected as the extraction reagent. The extraction efficiency of the five colourants in the proposed system is influenced by the types of salts, concentrations of salt and [CnMIM]Br, as well as the extracting time. Under the optimal conditions, the extraction efficiencies for these five colourants were above 95%. The phase behaviours of aqueous two-phase system and extraction mechanism were investigated by UV-vis spectroscopy. This method was applied to the analysis of the five colourants in real food samples with the detection limit of 0.051-0.074 ng/mL. Good spiked recoveries from 93.2% to 98.9% were obtained. Copyright © 2014 Elsevier Ltd. All rights reserved.
Selvaggini, Roberto; Servili, Maurizio; Urbani, Stefania; Esposto, Sonia; Taticchi, Agnese; Montedoro, GianFrancesco
2006-04-19
Hydrophilic phenols are the most abundant natural antioxidants of virgin olive oil (VOO), in which tocopherols and carotenes are also present. The prevalent classes of hydrophilic phenols found in VOO are phenyl alcohols, phenolic acids, secoiridoids such as the dialdehydic form of decarboxymethyl elenolic acid linked to (3,4-dihydroxyphenyl)ethanol or (p-hydroxypheny1)ethanol (3,4-DHPEA-EDA or p-HPEA-EDA) and an isomer of the oleuropein aglycon (3,4-DHPEA-EA), lignans such as (+)-1-acetoxypinoresinol and (+)-pinoresinol, and flavonoids. A new method for the analysis of VOO hydrophilic phenols by direct injection in high-performance liquid chromatography (HPLC) with the use of a fluorescence detector (FLD) has been proposed and compared with the traditional liquid-liquid extraction technique followed by the HPLC analysis utilizing a diode array detector (DAD) and a FLD. Results show that the most important classes of phenolic compounds occurring in VOO can be evaluated using HPLC direct injection. The efficiency of the new method, as compared to the liquid-liquid extraction, was higher to quantify phenyl alcohols, lignans, and 3,4-DHPEA-EA and lower for the evaluation of 3,4-DHPEA-EDA and p-HPEA-EDA.
Aeenehvand, Saeed; Toudehrousta, Zahra; Kamankesh, Marzieh; Mashayekh, Morteza; Tavakoli, Hamid Reza; Mohammadi, Abdorreza
2016-01-01
This study developed an analytical method based on microwave-assisted extraction and dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for the determination of three polar heterocyclic aromatic amines from hamburger patties. Effective parameters controlling the performance of the microextraction process, such as the type and volume of extraction and disperser solvents, microwave time, nature of alkaline aqueous solution, pH and salt amount, were optimized. The calibration graphs were linear in the range of 1-200 ng g(-1), with a coefficient of determination (R(2)) better than 0.9993. The relative standard deviations (RSD) for seven analyses were between 3.2% and 6.5%. The recoveries of those compounds in hamburger patties were from 90% to 105%. Detection limits were between 0.06 and 0.21 ng g(-1). A comparison of the proposed method with the existing literature demonstrates that it is a simple, rapid, highly selective and sensitive, and it gives good enrichment factors and detection limits for determining HAAs in real hamburger patties samples. Copyright © 2015 Elsevier Ltd. All rights reserved.
Faraji, M; Adeli, M
2017-04-15
A new and sensitive pre-column derivatization with dabsyl chloride followed by dispersive liquid-liquid microextraction was developed for the analysis of melamine (MEL) in raw milk and powdered infant formula samples by high performance liquid chromatography (HPLC) with visible detection. Derivatization with dabsyl chloride leads to improving sensitivity and hydrophobicity of MEL. Under optimum conditions of derivatization and microextraction steps, the method yielded a linear calibration curve ranging from 1.0 to 500μgL -1 with a determination coefficient (R 2 ) of 0.9995. Limit of detection and limit of quantification were 0.1 and 0.3μgL -1 , respectively. The relative standard deviation (RSD%) for intra-day (repeatability) and inter-day (reproducibility) at 25 and 100μgL -1 levels of MEL was less than 7.0% (n=6). Finally, the proposed method was successfully applied for the preconcentration and determination of MEL in different raw milk and powdered infant formula, and satisfactory results were obtained (relative recovery ⩾94%). Copyright © 2016 Elsevier Ltd. All rights reserved.
Chen, Chao-Jung; Chen, Wei-Yun; Tseng, Mei-Chun; Chen, Yet-Ran
2012-01-03
In this study, an easy method to fabricate a durable in-capillary frit was developed for use in nanoflow liquid chromatography (nanoLC). A small orifice was tunneled into the sol-gel frit during the polymerization process resulting in the simple fabrication of a tunnel frit. A short packing tunnel frit column (2 cm, C(18) particles) was able to sustain over 10,000 psi continuous liquid flow for 10 days without observation of particle loss, and back pressure variation was less than 5%. The tunnel frit was successfully applied to the fabrication of nanoflow ultra high-performance liquid chromatography (nano-UHPLC) trap and analytical columns. In the analysis of tryptic peptides, the tunnel frit trap and analytical columns were demonstrated to have high separation efficiency and sensitivity. In analysis of phosphopeptides, the use of the nonmetallic tunnel frit column showed better sensitivity than the metallic frit column. This design can facilitate the preparation of nano-HPLC and nano-UHPLC columns and the packing material can easily be refilled when the column is severely contaminated or clogged. © 2011 American Chemical Society
USDA-ARS?s Scientific Manuscript database
Flavonoids in different spinach genotypes were separated, identified, and quantified by a high-performance liquid chromatographic method with photodiode array and mass spectrometric detection. The antioxidant capacities of the genotypes were also measured using two antioxidant assays - oxygen radica...
A reversed-phase high-performance liquid chromatographic method for the separation and quantitation of a mixture consisting of nitrobenzene, dinitrobenzene isomers, 1,3,5-trinitrobenzene and their reduction products: aniline, nitroanilines and phenylenediamines has been developed...
Position sensitive radioactivity detection for gas and liquid chromatography
Cochran, Joseph L.; McCarthy, John F.; Palumbo, Anthony V.; Phelps, Tommy J.
2001-01-01
A method and apparatus are provided for the position sensitive detection of radioactivity in a fluid stream, particularly in the effluent fluid stream from a gas or liquid chromatographic instrument. The invention represents a significant advance in efficiency and cost reduction compared with current efforts.
Wang, Zhonghe; Yu, Jing; Yao, Jiaxi; Wu, Linlin; Xiao, Hang; Wang, Jun; Gao, Rong
2018-02-10
A method for the identification and quantification of bisphenol A and 12 bisphenol analogues in river water and sediment samples combining liquid-liquid extraction, precolumn derivatization, and ultra high-performance liquid chromatography coupled with tandem mass spectrometry was developed and validated. Analytes were extracted from the river water sample using a liquid-liquid extraction method. Dansyl chloride was selected as a derivatization reagent. Derivatization reaction conditions affecting production of the dansyl derivatives were tested and optimized. All the derivatized target compounds were well separated and eluted in 10 min. Dansyl chloride labeled compounds were analyzed using a high-resolution mass spectrometer with electrospray ionization in the positive mode, and the results were confirmed and quantified in the parallel reaction monitoring mode. The method validation results showed a satisfactory level of sensitivity. Linearity was assessed using matrix-matched standard calibration, and good correlation coefficients were obtained. The limits of quantification for the analytes ranged from 0.005 to 0.02 ng/mL in river water and from 0.15 to 0.80 ng/g in sediment. Good reproducibility of the method in terms of intra- and interday precision was achieved, yielding relative standard deviations of less than 10.1 and 11.6%, respectively. Finally, this method was successfully applied to the analysis of real samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sun, Mingqian; Liu, Jianxun; Lin, Chengren; Miao, Lan; Lin, Li
2014-01-01
Since alkaloids are the major active constituents of Rhizoma corydalis (RC), a convenient and accurate analytical method is needed for their identification and characterization. Here we report a method to profile the alkaloids in RC based on liquid chromatography-tandem quadrupole time-of-flight mass spectrometry (LC–Q-TOF-MS/MS). A total of 16 alkaloids belonging to four different classes were identified by comparison with authentic standards. The fragmentation pathway of each class of alkaloid was clarified and their differences were elucidated. Furthermore, based on an analysis of fragmentation pathways and alkaloid profiling, a rapid and accurate method for the identification of unknown alkaloids in RC is proposed. The method could also be useful for the quality control of RC. PMID:26579385
Amarasinghe, Kande; Chu, Pak-Sin; Evans, Eric; Reimschuessel, Renate; Hasbrouck, Nicholas; Jayasuriya, Hiranthi
2012-05-23
This paper describes the development of a fast method to screen and confirm methyltestosterone 17-O-glucuronide (MT-glu) in tilapia bile. The method consists of solid-phase extraction (SPE) followed by high-performance liquid chromatography-mass spectrometry. The system used was an Agilent 6530 Q-TOF with an Agilent Jet stream electrospray ionization interface. The glucuronide detected in the bile was characterized as MT-glu by comparison with a chemically synthesized standard. MT-glu was detected in bile for up to 7 days after dosing. Semiquantification was done with matrix-matched calibration curves, because MT-glu showed signal suppression due to matrix effects. This method provides a suitable tool to monitor the illegal use of methyltestosterone in tilapia culture.
Medić-Šarić, Marica; Rastija, Vesna; Bojić, Mirza; Maleš, Željan
2009-01-01
In the last decade we have been working on standardization of propolis extract and determination of active constituents of wine those are rich in polyphenolics and have nutritional as well as therapeutic value. Here we are summarizing our results and providing overview on systematic approach how to analyse natural products rich in flavonoids and phenolic acids. Chromatographic methods (thin layer chromatography and high performance liquid chromatography) were used for identification, quantification, and characterization of individual flavonoid or phenolic acid. Total content of active constituents and antioxidant activity were determined by spectrophotometry. Pharmacokinetic parameters were determined by high performance liquid chromatography and using appropriate software. Quantitative structure-activity relationship study of antioxidant activity was conducted, as well as assessment of prolonged propolis supplementation on antioxidative status of organism. Thin layer chromatography-densitometry has been proven as quick and reliable method for standard analysis of propolis and wine; the best mobile phase being chloroform – methanol – formic acid (98–100%) in ratio 44 : 3.5 : 2.5 (v/v). Higher number of polyphenolics was determined by high performance liquid chromatography; 15 compared to 9 by thin layer chromatography. Interactions in situ with acetylsalicylic acid were detected with most of polyphenolics analysed. Plasma protein binding and blood-barrier penetration was greatest for flavone. The interactions with human serum albumin have been grater than 95% for all flavonoids analysed. The prolonged propolis consumption increased superoxide dismutase activity. The necessity of standardization of natural products and their registration as functional nutraceuticals demand easy, quick and inexpensive methods of analysis. In this work we provided overview of analytical part for polyphenolics that could be used as data for possible registration of final products either as functional food or medicinal product. This feature introduces the readers to the authors' research through a concise overview of the selected topic. Reference to important work from others in the field is included. PMID:19624827
USDA-ARS?s Scientific Manuscript database
Traditional Chinese medicines (TCMs) have been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra Performance Liquid Chromatography (UHPLC) is a relatively new technique offering new possibilities in liquid chromatography. This paper reviews recen...
Book Chapter 18, titled Application in pesticide analysis: Liquid chromatography - A review of the state of science for biomarker discovery and identification, will be published in the book titled High Performance Liquid Chromatography in Pesticide Residue Analysis (Part of the C...
Weber, Berthold; Hartmann, Beate; Stöckigt, Detlef; Schreiber, Klaus; Roloff, Michael; Bertram, Heinz-Jürgen; Schmidt, Claus O
2006-01-25
Liquid chromatography/mass spectrometry and liquid chromatography/nuclear magnetic resonance techniques with ultraviolet/diode array detection were used as complementary analytical tools for the reliable identification of polymethoxylated flavones in residues from molecular distillation of cold-pressed peel oils of Citrus sinensis. After development of a liquid chromatographic separation procedure, the presence of several polymethoxy flavones such as sinensetin, nobiletin, tangeretin, quercetogetin, heptamethoxyflavone, and other derivatives was unambiguously confirmed. In addition, proceranone, an acetylated tetranortriterpenoid with limonoid structure, was identified for the first time in citrus.
Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi
2014-06-01
A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.
Bai, Lu; Guo, Sen; Liu, Qingchao; Cui, Xueqin; Zhang, Xinxin; Zhang, Li; Yang, Xinwen; Hou, Manwei; Ho, Chi-Tang; Bai, Naisheng
2016-04-01
Polyphenols are important bioactive substances in apple. To explore the profiles of the nine representative polyphenols in this fruit, a high-performance liquid chromatography method has been established and validated. The validated method was successfully applied for the simultaneous characterization and quantification of these nine apple polyphenols in 11 apple extracts, which were obtained from six cultivars from Shaanxi Province, China. The results showed that only abscission of the Fuji apple sample was rich in the nine apple polyphenols, and the polyphenol contents of other samples varied. Although all the samples were collected in the same region, the contents of nine polyphenols were different. The proposed method could serve as a prerequisite for quality control of Malus products. Copyright © 2015. Published by Elsevier B.V.
Khater, Syame; Lozac'h, Marie-Anne; Adam, Isabelle; Francotte, Eric; West, Caroline
2016-10-07
Analysis and production of enantiomerically pure compounds is a major topic of interest when active pharmaceutical ingredients are concerned. Enantioselective chromatography has become a favourite both at the analytical and preparative scales. High-performance liquid chromatography (HPLC) and supercritical fluid chromatography (SFC) are dominating the scene and are often seen as complementary techniques. Nowadays, for economic and ecologic reasons, SFC may be preferred over normal-phase HPLC (NPLC) as it allows significant reductions in solvent consumption. However, the transfer of NPLC methods to SFC is not always straightforward. In this study, we compare the retention of achiral molecules and separation of enantiomers under supercritical fluid (carbon dioxide with ethanol or isopropanol) and liquid normal-phase (heptane with ethanol or isopropanol) elution modes with polysaccharide stationary phases in order to explore the differences between the retention and enantioseparation properties between the two modes. Chemometric methods (namely quantitative structure-retention relationships and discriminant analysis) are employed to compare the results obtained on a large set of analytes (171 achiral probes and 97 racemates) and gain some understanding on the retention and separation mechanisms. The results indicate that, contrary to popular belief, carbon dioxide - solvent SFC mobile phases are often weaker eluents than liquid mobile phases. It appears that SFC and NPLC elution modes provide different retention mechanisms. While some enantioseparations are unaffected, facilitating the transfer between the two elution modes, other enantioseparations may be drastically different due to different types and strength of interactions contributing to enantioselectivity. Copyright © 2016 Elsevier B.V. All rights reserved.
Integration of electrochemistry with ultra-performance liquid chromatography/mass spectrometry.
Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A; Chen, Hao
2015-01-01
This study presents the development of ultra-performance liquid chromatography (UPLC) mass spectrometry (MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of proteins/peptides that contain disulfide bonds. In our approach, a protein/peptide mixture sample undergoes a fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and tandem mass spectrometry (MS/MS) analyses. The electrochemical cell is coupled to the mass spectrometer using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, peptides that contain disulfide bonds can be differentiated from those without disulfide bonds, as the former are electroactive and reducible. MS/MS analysis of the disulfide-reduced peptide ions provides increased information on the sequence and disulfide-linkage pattern. In a reactive DESI- MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which will be useful in top- down protein structure MS analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1(~)2 orders of magnitude by using UPLC for the liquid chromatography (LC)/EC/MS platform, in comparison to the previously used high- performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion, and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis.
Kawasaki, T; Maeda, M; Tsuji, A
1982-12-10
A fluorescence high-performance liquid chromatographic method is described for the direct determination of conjugated 17-oxosteroids in biological fluids without hydrolysis. Conjugated 17-oxosteroids are extracted with Sep-Pak C18 cartridge, labeled with dansyl hydrazine in trichloroacetic acid--benzene solution and then separated by high-performance liquid chromatography on reversed-phase muBondapak C18 column using 0.01 M sodium acetate in methanol-water-acetic acid (65:35:1, v/v) as the mobile phase. The eluate is monitored by a fluorophotometer at 365 nm (excitation) and 520 nm (emission). Linearities of fluorescence intensities (peak heights) with the amounts of various conjugated 17-oxosteroids were obtained between 10 pmol and 100 pmol. This method is sensitive, reliable and useful for the simultaneous determination of conjugated 17-oxosteroids in urine and serum.
Martínez-Moral, María Pilar; Tena, María Teresa
2012-11-15
The development and characterisation of a method based on reverse-phase ultra-performance liquid chromatography (UPLC) coupled to a quadrupole-time of flight mass spectrometer (Q-TOF-MS) with negative electrospray ionisation (ESI) to determine perfluorinated compounds (PFCs) in packaging is presented in this paper. Analytes were quantitatively recovered from packaging with methanol in only one PLE cycle of 6 min at 100 °C. The UPLC allowed the successful separation of the studied PFCs in less than 4 min. The whole method presented good precision, with RSDs below 8%, LODs from 0.6 to 16 ng g(-1); and excellent recovery values, around 100% in all cases, were achieved. The PLE-UPLC-MS method was applied to the analysis of popcorn packaging for microwave cooking. Besides the most commonly studied PFCs: PFOA and PFOS, the presence of other perfluorocarboxylic acids (PFCAs) in popcorn packaging is evidenced in this work. Copyright © 2012 Elsevier B.V. All rights reserved.
Li, Jing; Xie, Jianming; Yu, Jihua; Lv, Jian; Zhang, Junfeng; Wang, Xiaolong; Wang, Cheng; Tang, Chaonan; Zhang, Yingchun; Dawuda, Mohammed Mujitaba; Zhu, Daiqiang; Ma, Guoli
2017-09-27
Carotenoids are considered to be crucial elements in many fields and, furthermore, the significant factor in pepper leaves under low light and chilling temperature. However, little literature focused on the method to determinate and extract the contents of carotenoid compositions in pepper leaves. Therefore, a time-saving and highly sensitive reversed-phase high-performance liquid chromatography method for separation and quantification of 10 carotenoids was developed, and an optimized technological process for carotenoid composition extraction in pepper leaves was established for the first time. Our final method concluded that six xanthophylls eluted after about 9-26 min. In contrast, four carotenes showed higher retention times after nearly 28-40 min, which significantly shortened time and improved efficiency. Meanwhile, we suggested that 8 mL of 20% KOH-methanol solution should be added to perform saponification at 60 °C for 30 min. The ratio of solid-liquid was 1:8, and the ultrasound-assisted extraction time was 40 min.
Field, Christopher R.; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C.; Rose-Pehrsson, Susan L.
2014-01-01
The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples. PMID:25145416
Field, Christopher R; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C; Rose-Pehrsson, Susan L
2014-07-25
The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples.
Louveau, B; Fernandez, C; Zahr, N; Sauvageon-Martre, H; Maslanka, P; Faure, P; Mourah, S; Goldwirt, L
2016-12-01
A precise and accurate high-performance liquid chromatography (HPLC) quantification method of rifampicin in human plasma was developed and validated using ultraviolet detection after an automatized solid-phase extraction. The method was validated with respect to selectivity, extraction recovery, linearity, intra- and inter-day precision, accuracy, lower limit of quantification and stability. Chromatographic separation was performed on a Chromolith RP 8 column using a mixture of 0.05 m acetate buffer pH 5.7-acetonitrile (35:65, v/v) as mobile phase. The compounds were detected at a wavelength of 335 nm with a lower limit of quantification of 0.05 mg/L in human plasma. Retention times for rifampicin and 6,7-dimethyl-2,3-di(2-pyridyl) quinoxaline used as internal standard were respectively 3.77 and 4.81 min. This robust and exact method was successfully applied in routine for therapeutic drug monitoring in patients treated with rifampicin. Copyright © 2016 John Wiley & Sons, Ltd.
Phinney, Karen W; Rimmer, Catherine A; Thomas, Jeanice Brown; Sander, Lane C; Sharpless, Katherine E; Wise, Stephen A
2011-01-01
Vitamins are essential to human health, and dietary supplements containing vitamins are widely used by individuals hoping to ensure they have adequate intake of these important nutrients. Measurement of vitamins in nutritional formulations is necessary to monitor regulatory compliance and in studies examining the nutrient intake of specific populations. Liquid chromatographic methods, primarily with UV absorbance detection, are well established for both fat- and water-soluble measurements, but they do have limitations for certain analytes and may suffer from a lack of specificity in complex matrices. Liquid chromatography-mass spectrometry (LC-MS) provides both sensitivity and specificity for the determination of vitamins in these matrices, and simultaneous analysis of multiple vitamins in a single analysis is often possible. In this work, LC-MS methods were developed for both fat- and water-soluble vitamins and applied to the measurement of these analytes in two NIST Standard Reference Materials. When possible, stable isotope labeled internal standards were employed for quantification.
Levison, Bruce S.; Zhang, Renliang; Wang, Zeneng; Fu, Xiaoming; DiDonato, Joseph A.; Hazen, Stanley L.
2013-01-01
Oxidized fatty acids formed via lipid peroxidation are implicated in pathological processes such as inflammation and atherosclerosis. A number of methods may be used to detect specific oxidized fatty acids containing a single or multiple combinations of epoxide, hydroxyl, ketone and hydroperoxide moieties on varying carbon chain lengths from C8 up to C30. Some of these methods are nonspecific and their use in biological systems is fraught with difficulty. Measures of specific-oxidized fatty acid derivatives help in identifying oxidation pathways in pathological processes. We used liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC-MS/MS) as efficient, selective and sensitive methods for identifying and analyzing multiple specific fatty acid peroxidation products in human plasma and other biological matrices. We then distilled the essential components of a number of these analyses to provide an efficient protocol by which fatty acid oxidation products and their parent compounds can be determined. In this protocol, addition of synthetic internal standard to the sample, followed by base hydrolysis at elevated temperature, and liquid-liquid phase sample extraction with lighter than water solvents facilitates isolation of the oxidized fatty acid species. These species can be identified and accurately quantified using stable isotope dilution and multiple reaction monitoring. Use of a coupled multiplexed gradient HPLC system on the front end enables high-throughput chromatography and more efficient use of mass spectrometer time. PMID:23499838
Strum, John S; Aldredge, Danielle; Barile, Daniela; Lebrilla, Carlito B
2012-05-15
Mass spectrometry has been coupled with flash liquid chromatography to yield new capabilities for isolating nonchromophoric material from complicated biological mixtures. A flash liquid chromatography/tandem mass spectrometry (LC/MS/MS) method enabled fraction collection of milk oligosaccharides from biological mixtures based on composition and structure. The method is compatible with traditional gas pressure-driven flow flash chromatography widely employed in organic chemistry laboratories. The online mass detector enabled real-time optimization of chromatographic parameters to favor separation of oligosaccharides that would otherwise be indistinguishable from coeluting components with a nonspecific detector. Unlike previously described preparative LC/MS techniques, we have employed a dynamic flow connection that permits any flow rate from the flash system to be delivered from 1 to 200 ml/min without affecting the ionization conditions of the mass spectrometer. A new way of packing large amounts of graphitized carbon allowed the enrichment and separation of milligram quantities of structurally heterogeneous mixtures of human milk oligosaccharides (HMOs) and bovine milk oligosaccharides (BMOs). Abundant saccharide components in milk, such as lactose and lacto-N-tetraose, were separated from the rarer and less abundant oligosaccharides that have greater structural diversity and biological functionality. Neutral and acidic HMOs and BMOs were largely separated and enriched with a dual binary solvent system. Published by Elsevier Inc.
Fan, Chen; Cao, Xueli; Liu, Man; Wang, Wei
2016-03-04
Alternariol (AOH), alternariol monomethyl ether (AME), and tenuazonic acid (TeA) are some of the main Alternaria mycotoxins that can be found as contaminants in food materials. The objective of this study was to develop a pretreatment method with countercurrent chromatography (CCC) for enrichment and cleanup of trace Alternaria mycotoxins in food samples prior to high-performance liquid chromatography (HPLC) analysis. An Analytical CCC instrument with a column volume 22.5mL was used, and a two-phase solvent system composed of ethyl acetate and water modified with 6% [HOOMIM][Cl] in mass to volume ratio was selected. Under the optimized CCC operation conditions, trace amounts of AOH, AME, and TeA in large volume of liquid sample were efficiently extracted and enriched in the stationary phase, and then eluted out just by reversing the stationary phase as mobile phase in the opposite flowing direction tail-to-head. The enrichment and elution strategies are unique and can be fulfilled online with high enrichment factors (87-114) and high recoveries (81.14-110.94%). The method has been successively applied to the determination of Alternaria mycotoxins in real apple juice and wine samples with the limits of detection (LOD) in the range of 0.03-0.14μgL(-1). Totally 12 wine samples and 15 apple juice samples from the local market were analyzed. The detection rate of AOH and AME in both kinds of the samples were more than 50%, while TeA was found in relatively high level of 1.75-49.61μgL(-1) in some of the apple juice samples. The proposed method is simple, rapid, and sensitive and could also be used for the analysis and monitoring of Alternaria mycotoxin in other food samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Romarís-Hortas, Vanessa; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2012-05-04
Anion exchange high performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry has been novelly applied to assess inorganic (iodide and iodate) and organic (3-iodotyrosine - MIT, and 3,5-diiodotyrosine - DIT) iodine species in a single chromatographic run. The optimized operating conditions (Dionex IonPac AS7, gradient elution with 175 mM ammonium nitrate plus 15% (v/v) methanol, pH 3.8, as a mobile phase and flow rates within the 0.5-1.5 mL min(-1) range) have also been used to perform inorganic bromine speciation analysis (bromide and bromate). The developed method has been applied for determining the bio-available contents of iodine and bromine species in dialyzates from edible seaweed. Reverse phase high performance liquid chromatography (Zorbax Eclipse XDB-C8, gradient elution with 0.2% (m/m) acetic acid, and 0.2% (m/m) acetic acid in methanol, as mobile phases, and a constant flow rate of 0.75 mL min(-1)) also hyphenated with inductively coupled plasma-mass spectrometry was used to confirm the presence of organic iodine species (MIT and DIT) in the dialyzates. The verification of the presence of iodinated amino acids (MIT and DIT) in the extracts was also performed by reverse phase high performance liquid chromatography-electrospray ionization-mass spectrometry (LTQ Orbitrap). The developed methods have provided good repeatability (RSD values lower than 10% for both anion exchange and reverse phase separations) and analytical recoveries within the 90-105% range for all cases. The in vitro bio-availability method consisted of a simulated gastric and an intestinal digestion/dialysis (10 kDa molecular weight cut-off - MWCO) two-stage procedure. Iodide and MIT were the main bio-available species quantified, whereas bromide was the major bromine species found in the extracts. Copyright © 2012 Elsevier B.V. All rights reserved.
Wang, Hong-Ping; Zhang, You-Bo; Yang, Xiu-Wei; Yang, Xin-Bao; Xu, Wei; Xu, Feng; Cai, Shao-Qing; Wang, Ying-Ping; Xu, Yong-Hua; Zhang, Lian-Xue
2016-05-09
Ginseng, Panax ginseng C. A. Meyer, is an industrial crop in China and Korea. The functional components in ginseng roots and rhizomes are characteristic ginsenosides. This work developed a new high-performance liquid chromatography coupled with electrospray ionization ion trap time-of-flight multistage mass spectrometry (LC-ESI-IT-TOF-MS(n)) method to identify the triterpenoids. Sixty compounds (1-60) including 58 triterpenoids were identified from the ginseng cultivated in China. Substances 1, 2, 7, 15-20, 35, 39, 45-47, 49, 55-57, 59, and 60 were identified for the first time. To evaluate the quality of ginseng cultivated in Northeast China, this paper developed a practical liquid chromatography-diode array detection (LC-DAD) method to simultaneously quantify 14 interesting ginsenosides in ginseng collected from 66 different producing areas for the first time. The results showed the quality of ginseng roots and rhizomes from different sources was different due to growing environment, cultivation technology, and so on. The developed LC-ESI-IT-TOF-MS(n) method can be used to identify many more ginsenosides and the LC-DAD method can be used not only to assess the quality of ginseng, but also to optimize the cultivation conditions for the production of ginsenosides.
Mixed Stationary Liquid Phases for Gas-Liquid Chromatography.
ERIC Educational Resources Information Center
Koury, Albert M.; Parcher, Jon F.
1979-01-01
Describes a laboratory technique for use in an undergraduate instrumental analysis course that, using the interpretation of window diagrams, prepares a mixed liquid phase column for gas-liquid chromatography. A detailed procedure is provided. (BT)
Lin, Che-Yi; Fuh, Ming-Ren; Huang, Shang-Da
2011-02-01
A method termed liquid-liquid-liquid microextraction (LLLME) was utilized to extract 4-t-butylphenol, 4-t-octylphenol, 4-n-nonylphenol, and bisphenol-A from water. The extracted target analytes were separated and quantified by high-performance liquid chromatography using a fluorescence detector. In LLLME, the donor phase (i.e. water sample) was made weakly acidic by adding monobasic potassium phosphate (KH(2) PO(4)); the organic phase adopted was 4-chlorotoluene; the acceptor phase (i.e. enriched extract) was 0.2 M tetraethylammonium hydroxide dissolved in ethylene glycol. This study solves a problem associated with the surface activity of long-chain alkylphenolate ions, permitting LLLME to extract long-chain alkylphenols. Experimental conditions such as acceptor phase composition, organic phase identity, acceptor phase volume, sample agitation, extraction time, and salt addition were optimized. The relative standard deviation (RSD, 2.0-5.8%), coefficient of determination (r(2) 0.9977-0.9999), and detection limit (0.017-0.0048 ng/mL) of the proposed method were achieved under the selected optimized conditions. The method was successfully applied to analyses of lake and tap water samples, and the relative recoveries of target analytes from the spiked lake and tap water samples were 92.8-106.3 and 93.6-105.6%, respectively. The results obtained with the proposed method confirm this microextraction technique to be reliable for the monitoring of alkylphenols and bisphenol-A in water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.