14 CFR 27.337 - Limit maneuvering load factor.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factor. 27.337... Limit maneuvering load factor. The rotorcraft must be designed for— (a) A limit maneuvering load factor... load factor not less than 2.0 and any negative limit maneuvering load factor of not less than −0.5 for...
14 CFR 29.337 - Limit maneuvering load factor.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factor. 29.337... Limit maneuvering load factor. The rotorcraft must be designed for— (a) A limit maneuvering load factor... load factor not less than 2.0 and any negative limit maneuvering load factor of not less than −0.5 for...
14 CFR 23.337 - Limit maneuvering load factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factors. 23.337... Flight Loads § 23.337 Limit maneuvering load factors. (a) The positive limit maneuvering load factor n... airplanes; or (3) 6.0 for acrobatic category airplanes. (b) The negative limit maneuvering load factor may...
14 CFR 25.1531 - Maneuvering flight load factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Maneuvering flight load factors. 25.1531... Operating Limitations § 25.1531 Maneuvering flight load factors. Load factor limitations, not exceeding the positive limit load factors determined from the maneuvering diagram in § 25.333(b), must be established. ...
14 CFR 23.473 - Ground load conditions and assumptions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... vertical inertia load factor at the center of gravity of the airplane for the ground load conditions... through the center of gravity. The ground reaction load factor may be equal to the inertia load factor..., these tests must be made under § 23.723(a). (g) No inertia load factor used for design purposes may be...
14 CFR 23.473 - Ground load conditions and assumptions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... vertical inertia load factor at the center of gravity of the airplane for the ground load conditions... through the center of gravity. The ground reaction load factor may be equal to the inertia load factor..., these tests must be made under § 23.723(a). (g) No inertia load factor used for design purposes may be...
14 CFR 23.473 - Ground load conditions and assumptions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... vertical inertia load factor at the center of gravity of the airplane for the ground load conditions... through the center of gravity. The ground reaction load factor may be equal to the inertia load factor..., these tests must be made under § 23.723(a). (g) No inertia load factor used for design purposes may be...
14 CFR 23.473 - Ground load conditions and assumptions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... vertical inertia load factor at the center of gravity of the airplane for the ground load conditions... through the center of gravity. The ground reaction load factor may be equal to the inertia load factor..., these tests must be made under § 23.723(a). (g) No inertia load factor used for design purposes may be...
14 CFR 23.473 - Ground load conditions and assumptions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... vertical inertia load factor at the center of gravity of the airplane for the ground load conditions... through the center of gravity. The ground reaction load factor may be equal to the inertia load factor..., these tests must be made under § 23.723(a). (g) No inertia load factor used for design purposes may be...
14 CFR 23.527 - Hull and main float load factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hull and main float load factors. 23.527... Water Loads § 23.527 Hull and main float load factors. (a) Water reaction load factors nw must be...=seaplane landing weight in pounds. (6) K1=empirical hull station weighing factor, in accordance with figure...
14 CFR 23.527 - Hull and main float load factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Water Loads § 23.527 Hull and main float load factors. (a) Water reaction load factors nw must be... landing cases EC28SE91.005 (b) The following values are used: (1) nw=water reaction load factor (that is, the water reaction divided by seaplane weight). (2) C1=empirical seaplane operations factor equal to 0...
14 CFR 31.23 - Flight load factor.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flight load factor. 31.23 Section 31.23... STANDARDS: MANNED FREE BALLOONS Strength Requirements § 31.23 Flight load factor. In determining limit load, the limit flight load factor must be at least 1.4. ...
14 CFR 31.23 - Flight load factor.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flight load factor. 31.23 Section 31.23... STANDARDS: MANNED FREE BALLOONS Strength Requirements § 31.23 Flight load factor. In determining limit load, the limit flight load factor must be at least 1.4. ...
14 CFR 31.23 - Flight load factor.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flight load factor. 31.23 Section 31.23... STANDARDS: MANNED FREE BALLOONS Strength Requirements § 31.23 Flight load factor. In determining limit load, the limit flight load factor must be at least 1.4. ...
14 CFR 25.527 - Hull and main float load factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... float load factors. (a) Water reaction load factors n W must be computed in the following manner: (1... following values are used: (1) n W=water reaction load factor (that is, the water reaction divided by...
14 CFR 23.341 - Gust loads factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Gust loads factors. 23.341 Section 23.341... loads factors. (a) Each airplane must be designed to withstand loads on each lifting surface resulting... criteria of § 23.333(c). (c) In the absence of a more rational analysis, the gust load factors must be...
Calibration of LRFR live load factors using weigh-in-motion data.
DOT National Transportation Integrated Search
2006-06-01
The Load and Resistance Factor Rating (LRFR) code for load rating bridges is based on factors calibrated from structural : load and resistance statistics to achieve a more uniform level of reliability for all bridges. The liveload factors in the : LR...
14 CFR 25.1531 - Maneuvering flight load factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Maneuvering flight load factors. 25.1531 Section 25.1531 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Operating Limitations § 25.1531 Maneuvering flight load factors. Load factor limitations, not exceeding the...
14 CFR 25.1531 - Maneuvering flight load factors.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Maneuvering flight load factors. 25.1531 Section 25.1531 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Operating Limitations § 25.1531 Maneuvering flight load factors. Load factor limitations, not exceeding the...
14 CFR 398.9 - Load factor standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Load factor standards. 398.9 Section 398.9... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.9 Load factor standards. The load factor standards used in this part may be raised for individual eligible places under...
14 CFR 25.337 - Limit maneuvering load factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Limit maneuvering load factors. 25.337... Conditions § 25.337 Limit maneuvering load factors. (a) Except where limited by maximum (static) lift... maneuvering load factors prescribed in this section. Pitching velocities appropriate to the corresponding pull...
Ximénez, Carmen
2016-01-01
This article extends previous research on the recovery of weak factor loadings in confirmatory factor analysis (CFA) by exploring the effects of adding the mean structure. This issue has not been examined in previous research. This study is based on the framework of Yung and Bentler (1999) and aims to examine the conditions that affect the recovery of weak factor loadings when the model includes the mean structure, compared to analyzing the covariance structure alone. A simulation study was conducted in which several constraints were defined for one-, two-, and three-factor models. Results show that adding the mean structure improves the recovery of weak factor loadings and reduces the asymptotic variances for the factor loadings, particularly for the models with a smaller number of factors and a small sample size. Therefore, under certain circumstances, modeling the means should be seriously considered for covariance models containing weak factor loadings. PMID:26779071
An alternative method for centrifugal compressor loading factor modelling
NASA Astrophysics Data System (ADS)
Galerkin, Y.; Drozdov, A.; Rekstin, A.; Soldatova, K.
2017-08-01
The loading factor at design point is calculated by one or other empirical formula in classical design methods. Performance modelling as a whole is out of consideration. Test data of compressor stages demonstrates that loading factor versus flow coefficient at the impeller exit has a linear character independent of compressibility. Known Universal Modelling Method exploits this fact. Two points define the function - loading factor at design point and at zero flow rate. The proper formulae include empirical coefficients. A good modelling result is possible if the choice of coefficients is based on experience and close analogs. Earlier Y. Galerkin and K. Soldatova had proposed to define loading factor performance by the angle of its inclination to the ordinate axis and by the loading factor at zero flow rate. Simple and definite equations with four geometry parameters were proposed for loading factor performance calculated for inviscid flow. The authors of this publication have studied the test performance of thirteen stages of different types. The equations are proposed with universal empirical coefficients. The calculation error lies in the range of plus to minus 1,5%. The alternative model of a loading factor performance modelling is included in new versions of the Universal Modelling Method.
Perceptual load in different regions of the visual scene and its relevance for driving.
Marciano, Hadas; Yeshurun, Yaffa
2015-06-01
The aim of this study was to better understand the role played by perceptual load, at both central and peripheral regions of the visual scene, in driving safety. Attention is a crucial factor in driving safety, and previous laboratory studies suggest that perceptual load is an important factor determining the efficiency of attentional selectivity. Yet, the effects of perceptual load on driving were never studied systematically. Using a driving simulator, we orthogonally manipulated the load levels at the road (central load) and its sides (peripheral load), while occasionally introducing critical events at one of these regions. Perceptual load affected driving performance at both regions of the visual scene. Critically, the effect was different for central versus peripheral load: Whereas load levels on the road mainly affected driving speed, load levels on its sides mainly affected the ability to detect critical events initiating from the roadsides. Moreover, higher levels of peripheral load impaired performance but mainly with low levels of central load, replicating findings with simple letter stimuli. Perceptual load has a considerable effect on driving, but the nature of this effect depends on the region of the visual scene at which the load is introduced. Given the observed importance of perceptual load, authors of future studies of driving safety should take it into account. Specifically, these findings suggest that our understanding of factors that may be relevant for driving safety would benefit from studying these factors under different levels of load at different regions of the visual scene. © 2014, Human Factors and Ergonomics Society.
Moving Aerospace Structural Design Practice to a Load and Resistance Factor Approach
NASA Technical Reports Server (NTRS)
Larsen, Curtis E.; Raju, Ivatury S.
2016-01-01
Aerospace structures are traditionally designed using the factor of safety (FOS) approach. The limit load on the structure is determined and the structure is then designed for FOS times the limit load - the ultimate load. Probabilistic approaches utilize distributions for loads and strengths. Failures are predicted to occur in the region of intersection of the two distributions. The load and resistance factor design (LRFD) approach judiciously combines these two approaches by intensive calibration studies on loads and strength to result in structures that are efficient and reliable. This paper discusses these three approaches.
Measuring cognitive load during procedural skills training with colonoscopy as an exemplar.
Sewell, Justin L; Boscardin, Christy K; Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S
2016-06-01
Few studies have investigated cognitive factors affecting learning of procedural skills in medical education. Cognitive load theory, which focuses on working memory, is highly relevant, but methods for measuring cognitive load during procedural training are not well understood. Using colonoscopy as an exemplar, we used cognitive load theory to develop a self-report instrument to measure three types of cognitive load (intrinsic, extraneous and germane load) and to provide evidence for instrument validity. We developed the instrument (the Cognitive Load Inventory for Colonoscopy [CLIC]) using a multi-step process. It included 19 items measuring three types of cognitive load, three global rating items and demographics. We then conducted a cross-sectional survey that was administered electronically to 1061 gastroenterology trainees in the USA. Participants completed the CLIC following a colonoscopy. The two study phases (exploratory and confirmatory) each lasted for 10 weeks during the 2014-2015 academic year. Exploratory factor analysis determined the most parsimonious factor structure; confirmatory factor analysis assessed model fit. Composite measures of intrinsic, extraneous and germane load were compared across years of training and with global rating items. A total of 477 (45.0%) invitees participated (116 in the exploratory study and 361 in the confirmatory study) in 154 (95.1%) training programmes. Demographics were similar to national data from the USA. The most parsimonious factor structure included three factors reflecting the three types of cognitive load. Confirmatory factor analysis verified that a three-factor model was the best fit. Intrinsic, extraneous and germane load items had high internal consistency (Cronbach's alpha 0.90, 0.87 and 0.96, respectively) and correlated as expected with year in training and global assessment of cognitive load. The CLIC measures three types of cognitive load during colonoscopy training. Evidence of validity is provided. Although CLIC items relate to colonoscopy, the development process we detail can be used to adapt the instrument for use in other learning settings in medical education. © 2016 John Wiley & Sons Ltd.
DOT National Transportation Integrated Search
2016-06-01
Load and Resistance Factor Rating (LRFR) is a reliability-based rating procedure complementary to Load and Resistance Factor Design (LRFD). The intent of LRFR is to provide consistent reliability for all bridges regardless of in-situ condition. The p...
14 CFR 23.525 - Application of loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the loads corresponding to the load factors specified in § 23.527. (b) In applying the loads resulting from the load factors prescribed in § 23.527, the loads may be distributed over the hull or main float... on the seaplane during the impact is assumed to be 2/3 of the weight of the seaplane. [Doc. No. 26269...
14 CFR 23.525 - Application of loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the loads corresponding to the load factors specified in § 23.527. (b) In applying the loads resulting from the load factors prescribed in § 23.527, the loads may be distributed over the hull or main float... on the seaplane during the impact is assumed to be 2/3 of the weight of the seaplane. [Doc. No. 26269...
14 CFR 23.525 - Application of loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the loads corresponding to the load factors specified in § 23.527. (b) In applying the loads resulting from the load factors prescribed in § 23.527, the loads may be distributed over the hull or main float... on the seaplane during the impact is assumed to be 2/3 of the weight of the seaplane. [Doc. No. 26269...
14 CFR 23.525 - Application of loads.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the loads corresponding to the load factors specified in § 23.527. (b) In applying the loads resulting from the load factors prescribed in § 23.527, the loads may be distributed over the hull or main float... on the seaplane during the impact is assumed to be 2/3 of the weight of the seaplane. [Doc. No. 26269...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
Zhang, Zhenzhen; O'Neill, Marie S; Sánchez, Brisa N
2016-04-01
Factor analysis is a commonly used method of modelling correlated multivariate exposure data. Typically, the measurement model is assumed to have constant factor loadings. However, from our preliminary analyses of the Environmental Protection Agency's (EPA's) PM 2.5 fine speciation data, we have observed that the factor loadings for four constituents change considerably in stratified analyses. Since invariance of factor loadings is a prerequisite for valid comparison of the underlying latent variables, we propose a factor model that includes non-constant factor loadings that change over time and space using P-spline penalized with the generalized cross-validation (GCV) criterion. The model is implemented using the Expectation-Maximization (EM) algorithm and we select the multiple spline smoothing parameters by minimizing the GCV criterion with Newton's method during each iteration of the EM algorithm. The algorithm is applied to a one-factor model that includes four constituents. Through bootstrap confidence bands, we find that the factor loading for total nitrate changes across seasons and geographic regions.
Parameter Accuracy in Meta-Analyses of Factor Structures
ERIC Educational Resources Information Center
Gnambs, Timo; Staufenbiel, Thomas
2016-01-01
Two new methods for the meta-analysis of factor loadings are introduced and evaluated by Monte Carlo simulations. The direct method pools each factor loading individually, whereas the indirect method synthesizes correlation matrices reproduced from factor loadings. The results of the two simulations demonstrated that the accuracy of…
Dwivedi, Dipankar; Mohanty, Binayak P.; Lesikar, Bruce J.
2013-01-01
Microbes have been identified as a major contaminant of water resources. Escherichia coli (E. coli) is a commonly used indicator organism. It is well recognized that the fate of E. coli in surface water systems is governed by multiple physical, chemical, and biological factors. The aim of this work is to provide insight into the physical, chemical, and biological factors along with their interactions that are critical in the estimation of E. coli loads in surface streams. There are various models to predict E. coli loads in streams, but they tend to be system or site specific or overly complex without enhancing our understanding of these factors. Hence, based on available data, a Bayesian Neural Network (BNN) is presented for estimating E. coli loads based on physical, chemical, and biological factors in streams. The BNN has the dual advantage of overcoming the absence of quality data (with regards to consistency in data) and determination of mechanistic model parameters by employing a probabilistic framework. This study evaluates whether the BNN model can be an effective alternative tool to mechanistic models for E. coli loads estimation in streams. For this purpose, a comparison with a traditional model (LOADEST, USGS) is conducted. The models are compared for estimated E. coli loads based on available water quality data in Plum Creek, Texas. All the model efficiency measures suggest that overall E. coli loads estimations by the BNN model are better than the E. coli loads estimations by the LOADEST model on all the three occasions (three-fold cross validation). Thirteen factors were used for estimating E. coli loads with the exhaustive feature selection technique, which indicated that six of thirteen factors are important for estimating E. coli loads. Physical factors included temperature and dissolved oxygen; chemical factors include phosphate and ammonia; biological factors include suspended solids and chlorophyll. The results highlight that the LOADEST model estimates E. coli loads better in the smaller ranges, whereas the BNN model estimates E. coli loads better in the higher ranges. Hence, the BNN model can be used to design targeted monitoring programs and implement regulatory standards through TMDL programs. PMID:24511166
Calibration of the live load factor in LRFD design guidelines.
DOT National Transportation Integrated Search
2010-09-01
The Load and Resistant Factor Design (LRFD) approach is based on the concept of structural reliability. The approach is : more rational than the former design approaches such as Load Factor Design or Allowable Stress Design. The LRFD : Specification ...
Calibration of the live load factor in LRFD design guidelines : [revised].
DOT National Transportation Integrated Search
2011-07-01
The Load and Resistant Factor Design (LRFD) approach is based on the concept of structural reliability. The approach is : more rational than the former design approaches such as Load Factor Design or Allowable Stress Design. The LRFD : Specification ...
Research notes : customized live-load factors for bridge load rating.
DOT National Transportation Integrated Search
2007-03-01
The state-of-the-art approach to load rating bridges is the Load and Resistance Factor Rating (LRFR) method, supported by the Federal Highway Administration and the American Association of State Highway and Transportation Officials. This approach ens...
NASA Technical Reports Server (NTRS)
Kussner, H G; Thalau, Karl
1933-01-01
Load factors and loading conditions are presented for German aircraft. Loading conditions under various stress factors are presented along with a breakdown of individual aircraft components such as landing gear, wings, etc.
Exploratory factor analysis of the functional movement screen in elite athletes.
Li, Yongming; Wang, Xiong; Chen, Xiaoping; Dai, Boyi
2015-01-01
The functional movement screen is developed to examine individuals' movement patterns through 7 functional tasks. The purpose of this study was to identify the internal consistency and factor structure of the 7 tasks of the functional movement screen in elite athletes; 290 elite athletes from a variety of Chinese national teams were assessed using the functional movement screen. Cronbach's alpha was calculated for the scores of the 7 tasks. Exploratory factor analysis was performed to explore the factor structure of the functional movement screen. The mean and standard deviation of the sum score were 15.2 ± 3.0. A low Cronbach's alpha (0.58) was found for the scores of the 7 tasks. Exploratory factor analysis extracted 2 factors with eigenvalues greater than 1, and these 2 factors explained 47.3% of the total variance. The first factor had a high loading on the rotatory stability (loading = 0.99) and low loadings on the other 6 tasks (loading range: 0.04-0.34). The second factor had high loadings on the deep squat, hurdle step and inline lunge (loading range: 0.46-0.61) and low loadings on the other 3 tasks (loading range: 0.12-0.32). The 7 tasks of the functional movement screen had low internal consistency and were not indicators of a single factor. Evidence for unidimensionality was not found for the functional movement screen in elite athletes. More attention should be paid to the score of each task rather than the sum score when we interpret the functional movement screen scores.
Weigh-in-motion (WIM) data for site-specific LRFR bridge load rating.
DOT National Transportation Integrated Search
2011-08-12
The live load factors in the Load and Resistant Factor Rating (LRFR) Manual are based on load data from Ontario : thought to be representative of traffic volumes nationwide. However, in accordance with the methodology for : developing site-specific l...
Quality factor concept in piezoceramic transformer performance description.
Mezheritsky, Alex V
2006-02-01
A new general approach based on the quality factor concept to piezoceramic transformer (PT) performance description is proposed. The system's quality factor, material elastic anisotropy, and coupling factors of the input and output sections of an electrically excited and electrically loaded PT fully characterize its resonance and near-resonance behavior. The PT efficiency, transformation ratio, and input and output power were analytically analyzed and simulated as functions of the load and frequency for the simplest classical Langevin-type and Rosen-type PT designs. A new formulation of the electrical input impedance allows one to separate the power consumed by PT from the power transferred into the load. The system's PT quality factor takes into account losses in each PT "input-output-load" functional components. The loading process is changing PT input electrical impedance on the way that under loading the minimum series impedance is increasing and the maximum parallel impedance is decreasing coincidentally. The quality-factors ratio, between the states of fully loaded and nonloaded PT, is one of the best measures of PTs dynamic performance--practically, the lower the ratio is, the better PT efficiency. A simple and effective method for the loaded PT quality factor determination is proposed. As was found, a piezoceramic with low piezoelectric anisotropy is required to provide maximum PT efficiency and higher corresponding voltage gain. Limitations on the PT output voltage and power, caused by nonlinear effects in piezoceramics, were established.
Impact of measurement uncertainty from experimental load distribution factors on bridge load rating
NASA Astrophysics Data System (ADS)
Gangone, Michael V.; Whelan, Matthew J.
2018-03-01
Load rating and testing of highway bridges is important in determining the capacity of the structure. Experimental load rating utilizes strain transducers placed at critical locations of the superstructure to measure normal strains. These strains are then used in computing diagnostic performance measures (neutral axis of bending, load distribution factor) and ultimately a load rating. However, it has been shown that experimentally obtained strain measurements contain uncertainties associated with the accuracy and precision of the sensor and sensing system. These uncertainties propagate through to the diagnostic indicators that in turn transmit into the load rating calculation. This paper will analyze the effect that measurement uncertainties have on the experimental load rating results of a 3 span multi-girder/stringer steel and concrete bridge. The focus of this paper will be limited to the uncertainty associated with the experimental distribution factor estimate. For the testing discussed, strain readings were gathered at the midspan of each span of both exterior girders and the center girder. Test vehicles of known weight were positioned at specified locations on each span to generate maximum strain response for each of the five girders. The strain uncertainties were used in conjunction with a propagation formula developed by the authors to determine the standard uncertainty in the distribution factor estimates. This distribution factor uncertainty is then introduced into the load rating computation to determine the possible range of the load rating. The results show the importance of understanding measurement uncertainty in experimental load testing.
Fundamental concepts of structural loading and load relief techniques for the space shuttle
NASA Technical Reports Server (NTRS)
Ryan, R. S.; Mowery, D. K.; Winder, S. W.
1972-01-01
The prediction of flight loads and their potential reduction, using various control system logics for the space shuttle vehicles, is discussed. Some factors not found on previous launch vehicles that increase the complexity are large lifting surfaces, unsymmetrical structure, unsymmetrical aerodynamics, trajectory control system coupling, and large aeroelastic effects. These load-producing factors and load-reducing techniques are analyzed.
14 CFR 25.527 - Hull and main float load factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hull and main float load factors. 25.527... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Structure Water Loads § 25.527 Hull and main... 1=empirical hull station weighing factor, in accordance with figure 2 of appendix B. (7) r x=ratio...
Testing Measurement Invariance Using MIMIC: Likelihood Ratio Test with a Critical Value Adjustment
ERIC Educational Resources Information Center
Kim, Eun Sook; Yoon, Myeongsun; Lee, Taehun
2012-01-01
Multiple-indicators multiple-causes (MIMIC) modeling is often used to test a latent group mean difference while assuming the equivalence of factor loadings and intercepts over groups. However, this study demonstrated that MIMIC was insensitive to the presence of factor loading noninvariance, which implies that factor loading invariance should be…
NASA Technical Reports Server (NTRS)
Hartranft, R. J.; Sih, G. C.
1973-01-01
The closed form expressions for the stress intensity factors due to concentrated forces applied to the surfaces of a half plane crack in an infinite body are used to generate solutions for distributed loads in this geometry. The stress intensity factors for uniformly distributed loads applied over a rectangular portion of the crack surface are given in closed form. An example of non-uniformly distributed loads which can be treated numerically is also included. In particular, combinations of normal and shear stresses on the crack which simulate the case of loading at an angle to the crack front are considered. The resulting stress intensity factors are combined with the strain energy density fracture criterion for the purpose of predicting the most likely direction of crack propagation. The critical value of the energy density factor can then be used for determining the allowable load on a specimen with a crack front not perpendicular to the tensile axis.
14 CFR 23.341 - Gust loads factors.
Code of Federal Regulations, 2014 CFR
2014-01-01
... loads factors. (a) Each airplane must be designed to withstand loads on each lifting surface resulting...=airplane mass ratio; U de=Derived gust velocities referred to in § 23.333(c) (f.p.s.); ρ=Density of air... C NA per radian if the gust loads are applied to the wings and horizontal tail surfaces...
14 CFR 23.341 - Gust loads factors.
Code of Federal Regulations, 2012 CFR
2012-01-01
... loads factors. (a) Each airplane must be designed to withstand loads on each lifting surface resulting...=airplane mass ratio; U de=Derived gust velocities referred to in § 23.333(c) (f.p.s.); ρ=Density of air... C NA per radian if the gust loads are applied to the wings and horizontal tail surfaces...
14 CFR 23.341 - Gust loads factors.
Code of Federal Regulations, 2013 CFR
2013-01-01
... loads factors. (a) Each airplane must be designed to withstand loads on each lifting surface resulting...=airplane mass ratio; U de=Derived gust velocities referred to in § 23.333(c) (f.p.s.); ρ=Density of air... C NA per radian if the gust loads are applied to the wings and horizontal tail surfaces...
14 CFR 23.341 - Gust loads factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... loads factors. (a) Each airplane must be designed to withstand loads on each lifting surface resulting...=airplane mass ratio; U de=Derived gust velocities referred to in § 23.333(c) (f.p.s.); ρ=Density of air... C NA per radian if the gust loads are applied to the wings and horizontal tail surfaces...
Meyer, N K; Ristovski, Z D
2007-11-01
The volatile and hygroscopic properties of diesel nanoparticles were simultaneously determined under a range of engine loads using the volatilization and humidification tandem differential mobility analyzer (VH-TDMA). Additionally, the VH-TDMA was used to measure changes in the hygroscopic behavior of the heterogeneously nucleated diesel nanoparticles as one or more semivolatile species were removed via thermal evaporation or decomposition. Particles produced at high loads exhibited high, dual-step volatility, while those particles produced at low loads were less volatile and exhibited continuous volatilization curves. The hygroscopic growth factor of the particles was shown to be load dependent with high-load particles exhibiting growth factors similar to that of ammonium sulfate. At 85% relative humidity, particles produced at moderate loads exhibited growth factors of approximately 1.1 while low-load particles were shown to be hydrophobic. Growth factors and volatilization temperatures measured for high-load particles clearly indicate that ternary nucleation is involved in particle formation.
Petzold, A; Weingartner, E; Hasselbach, J; Lauer, P; Kurok, C; Fleischer, F
2010-05-15
Particulate matter (PM) emissions from one serial 4-stroke medium-speed marine diesel engine were measured for load conditions from 10% to 110% in test rig studies using heavy fuel oil (HFO). Testing the engine across its entire load range permitted the scaling of exhaust PM properties with load. Emission factors for particle number, particle mass, and chemical compounds were determined. The potential of particles to form cloud droplets (cloud condensation nuclei, CCN) was calculated from chemical composition and particle size. Number emission factors are (3.43 +/- 1.26) x 10(16) (kg fuel)(-1) at 85-110% load and (1.06 +/- 0.10) x 10(16) (kg fuel)(-1) at 10% load. CCN emission factors of 1-6 x 10(14) (kg fuel)(-1) are at the lower bound of data reported in the literature. From combined thermal and optical methods, black carbon (BC) emission factors of 40-60 mg/(kg fuel) were determined for 85-100% load and 370 mg/(kg fuel) for 10% load. The engine load dependence of the conversion efficiency for fuel sulfur into sulfate of (1.08 +/- 0.15)% at engine idle to (3.85 +/- 0.41)% at cruise may serve as input to global emission calculations for various load conditions.
14 CFR 27.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor...
14 CFR 27.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor...
14 CFR 27.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor...
Improved LRFD/LRFR specifications for permit and fatigue load truck.
DOT National Transportation Integrated Search
2011-01-01
Bridge design and evaluation are moving toward the American Association of State Highway and Transportation : Officials (AASHTO) load and resistance factor design/load and resistance factor rating (LRFD/LRFR) : specifications using calibrated truck l...
Healthy eating opinion survey for individuals at risk for cardiovascular disease.
Mark, Amy E; Riley, Dana L; McDonnell, Lisa A; Pipe, Andrew L; Reid, Robert D
2014-08-01
To develop and evaluate the validity and reliability of a questionnaire to measure intentions and beliefs about healthy eating in individuals at risk for coronary heart disease. The Healthy Eating Opinion Survey was developed using the theory of planned behavior. An open-ended elicitation questionnaire was administered to 21 participants, and a 46-item questionnaire was developed for further testing. Test-retest reliability of each question on the survey was assessed by calculating the correlation coefficients between the responses over a 2- week period in 17 participants. Internal consistency was assessed using Cronbach's alpha, and factor analysis was used to assess the construct validity of the questionnaire in a sample of 388 participants. The responses to the elicitation questions were used to develop behavioral beliefs, normative beliefs, and control beliefs questions for the final questionnaire. Test-retest reliability ranged from 0.22-0.90, with the majority (89%) of correlations being moderate to strong. Internal consistency was good, with Cronbach's alpha ranging from 0.74-0.92. All intentions questions loaded onto a single factor; attitude questions loaded onto two factors; subjective norm questions loaded onto two factors; perceived behavioral control questions loaded onto one factor; behavioral beliefs questions loaded onto one factor; normative beliefs questions loaded onto one factor; and control beliefs questions loaded onto one factor. The questionnaire was found to be a reliable, valid questionnaire to assess beliefs and intentions toward eating a healthy diet in individuals at risk for coronary heart disease.
Ormel, J; Oldehinkel, A J; Ferdinand, R F; Hartman, C A; De Winter, A F; Veenstra, R; Vollebergh, W; Minderaa, R B; Buitelaar, J K; Verhulst, F C
2005-12-01
We investigated the links between familial loading, preadolescent temperament, and internalizing and externalizing problems in adolescence, hereby distinguishing effects on maladjustment in general versus dimension-specific effects on either internalizing or externalizing problems. In a population-based sample of 2230 preadolescents (10-11 years) familial loading (parental lifetime psychopathology) and offspring temperament were assessed at baseline by parent report, and offspring psychopathology at 2.5-years follow-up by self-report, teacher report and parent report. We used purified measures of temperament and psychopathology and partialled out shared variance between internalizing and externalizing problems. Familial loading of internalizing psychopathology predicted offspring internalizing but not externalizing problems, whereas familial loading of externalizing psychopathology predicted offspring externalizing but not internalizing problems. Both familial loadings were associated with Frustration, low Effortful Control, and Fear. Frustration acted as a general risk factor predicting severity of maladjustment; low Effortful Control and Fear acted as dimension-specific risk factors that predicted a particular type of psychopathology; whereas Shyness, High-Intensity Pleasure, and Affiliation acted as direction markers that steered the conditional probability of internalizing versus externalizing problems, in the event of maladjustment. Temperament traits mediated one-third of the association between familial loading and psychopathology. Findings were robust across different composite measures of psychopathology, and applied to girls as well as boys. With regard to familial loading and temperament, it is important to distinguish general risk factors (Frustration) from dimension-specific risk factors (familial loadings, Effortful Control, Fear), and direction markers that act as pathoplastic factors (Shyness, High-Intensity Pleasure, Affiliation) from both types of risk factors. About one-third of familial loading effects on psychopathology in early adolescence are mediated by temperament.
14 CFR 29.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor... factor of safety prescribed in § 29.303 need not be used. [Amdt. 29-3, 33 FR 966, Jan. 26, 1968] ...
14 CFR 29.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor... factor of safety prescribed in § 29.303 need not be used. [Amdt. 29-3, 33 FR 966, Jan. 26, 1968] ...
14 CFR 29.473 - Ground loading conditions and assumptions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... through the center of gravity throughout the landing impact. This lift may not exceed two-thirds of the... rotorcraft must be designed for a limit load factor of not less than the limit inertia load factor... factor of safety prescribed in § 29.303 need not be used. [Amdt. 29-3, 33 FR 966, Jan. 26, 1968] ...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
14 CFR 23.725 - Limit drop tests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...
Code of Federal Regulations, 2010 CFR
2010-01-01
... load would significantly change the distribution of external or internal loads, this redistribution...) and ultimate loads (limit loads multiplied by prescribed factors of safety). Unless otherwise provided...
Wind loads on flat plate photovoltaic array fields (nonsteady winds)
NASA Technical Reports Server (NTRS)
Miller, R. D.; Zimmerman, D. K.
1981-01-01
Techniques to predict the dynamic response and the structural dynamic loads of flat plate photovoltaic arrays due to wind turbulence were analyzed. Guidelines for use in predicting the turbulent portion of the wind loading on future similar arrays are presented. The dynamic response and the loads dynamic magnification factor of the two array configurations are similar. The magnification factors at a mid chord and outer chord location on the array illustrated and at four points on the chord are shown. The wind tunnel test experimental rms pressure coefficient on which magnification factors are based is shown. It is found that the largest response and dynamic magnification factor occur at a mid chord location on an array and near the trailing edge. A technique employing these magnification factors and the wind tunnel test rms fluctuating pressure coefficients to calculate design pressure loads due to wind turbulence is presented.
Control circuit maintains unity power factor of reactive load
NASA Technical Reports Server (NTRS)
Kramer, M.; Martinage, L. H.
1966-01-01
Circuit including feedback control elements automatically corrects the power factor of a reactive load. It maintains power supply efficiency where negative load reactance changes and varies by providing corrective error signals to the control windings of a power supply transformer.
14 CFR 25.531 - Hull and main float takeoff condition.
Code of Federal Regulations, 2011 CFR
2011-01-01
... wing lift is assumed to be zero; and (b) A downward inertia load, corresponding to a load factor computed from the following formula, must be applied: EC28SE91.038 where— n=inertia load factor; C TO...
14 CFR 25.531 - Hull and main float takeoff condition.
Code of Federal Regulations, 2013 CFR
2013-01-01
... wing lift is assumed to be zero; and (b) A downward inertia load, corresponding to a load factor computed from the following formula, must be applied: EC28SE91.038 where— n=inertia load factor; C TO...
14 CFR 25.531 - Hull and main float takeoff condition.
Code of Federal Regulations, 2014 CFR
2014-01-01
... wing lift is assumed to be zero; and (b) A downward inertia load, corresponding to a load factor computed from the following formula, must be applied: EC28SE91.038 where— n=inertia load factor; C TO...
14 CFR 25.531 - Hull and main float takeoff condition.
Code of Federal Regulations, 2012 CFR
2012-01-01
... wing lift is assumed to be zero; and (b) A downward inertia load, corresponding to a load factor computed from the following formula, must be applied: EC28SE91.038 where— n=inertia load factor; C TO...
NASA Technical Reports Server (NTRS)
Lee, H. M.
1992-01-01
It is shown that the mechanism of bolt loading for preloaded fasteners can be effectively portrayed through simple spring models and some algebraic manipulations. Understanding schematically what is involved in such joints provides insight into the distribution of loads. The developed equations confirm that for both symmetric and nonsymmetric joints the loading plane factor and the stiffness factor directly affect the load seen in preloaded fasteners. The manner in which an external loading is transferred through the joint can be explained as energy dissipated in the various springs of both the abutment and the bolt itself.
1989-03-01
comparison between the two. Tyre self-excited vibration can be caused by lack of uniforuity and/or out-of-balance. The authors suggest that driving ... safety is best described by the ’Dynamic Load Factor’ which relates the ainimum rolling dynamic load to the static tyre load. Dynamic Load Factors are
14 CFR 25.499 - Nose-wheel yaw and steering.
Code of Federal Regulations, 2012 CFR
2012-01-01
... steering. (a) A vertical load factor of 1.0 at the airplane center of gravity, and a side component at the... structure forward of the center of gravity must be designed for the following loads: (1) A vertical load factor at the center of gravity of 1.0. (2) A forward acting load at the airplane center of gravity of 0...
14 CFR 25.499 - Nose-wheel yaw and steering.
Code of Federal Regulations, 2013 CFR
2013-01-01
... steering. (a) A vertical load factor of 1.0 at the airplane center of gravity, and a side component at the... structure forward of the center of gravity must be designed for the following loads: (1) A vertical load factor at the center of gravity of 1.0. (2) A forward acting load at the airplane center of gravity of 0...
Creep crack growth by grain boundary cavitation under monotonic and cyclic loading
NASA Astrophysics Data System (ADS)
Wen, Jian-Feng; Srivastava, Ankit; Benzerga, Amine; Tu, Shan-Tung; Needleman, Alan
2017-11-01
Plane strain finite deformation finite element calculations of mode I crack growth under small scale creep conditions are carried out. Attention is confined to isothermal conditions and two time histories of the applied stress intensity factor: (i) a monononic increase to a plateau value subsequently held fixed; and (ii) a cyclic time variation. The crack growth calculations are based on a micromechanics constitutive relation that couples creep deformation and damage due to grain boundary cavitation. Grain boundary cavitation, with cavity growth due to both creep and diffusion, is taken as the sole failure mechanism contributing to crack growth. The influence on the crack growth rate of loading history parameters, such as the magnitude of the applied stress intensity factor, the ratio of the applied minimum to maximum stress intensity factors, the loading rate, the hold time and the cyclic loading frequency, are explored. The crack growth rate under cyclic loading conditions is found to be greater than under monotonic creep loading with the plateau applied stress intensity factor equal to its maximum value under cyclic loading conditions. Several features of the crack growth behavior observed in creep-fatigue tests naturally emerge, for example, a Paris law type relation is obtained for cyclic loading.
Mimura, Satoru; Kubota, Yumiko; Takisawa, Haruhiko
2018-01-01
The minichromosome maintenance (MCM) complex, consisting of six subunits, Mcm2-7, is loaded onto replication origins through loading factors (origin recognition complex [ORC], Cdc6, and Cdt1) and forms an MCM double hexamer that licenses the initiation of DNA replication. Previous studies with Xenopus egg extracts showed that loading factors, especially Cdc6, dissociate from chromatin on MCM loading, but the molecular mechanism and physiological significance remain largely unknown. Using a cell-free system for MCM loading onto plasmid DNA in Xenopus egg extracts, we found that MCM loaded onto DNA prevents DNA binding of the loading factors ORC, Cdc6, and Cdt1. We further report that a peptide of the C-terminal region of MCM3 (MCM3-C), previously implicated in the initial association with ORC/Cdc6 in budding yeast, prevents ORC/Cdc6/Cdt1 binding to DNA in the absence of MCM loading. ATP-γ-S suppresses inhibitory activities of both the MCM loaded onto DNA and the MCM3-C peptide. Other soluble factors in the extract, but neither MCM nor Cdt1, are required for the activity. Conservation of the amino acid sequences of MCM3-C and its activity in vertebrates implies a novel negative autoregulatory mechanism that interferes with MCM loading in the vicinity of licensed origins to ensure proper origin licensing.
14 CFR 27.337 - Limit maneuvering load factor.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Limit maneuvering load factor. 27.337 Section 27.337 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements Flight Loads § 27.337...
NASA Astrophysics Data System (ADS)
Hidayat, Dony; Istiyanto, Jos; Agus Sumarsono, Danardono
2018-04-01
Loads at main landing gear while touchdown impact is function of aircraft weight and ground reaction load factor. In regulation states ground reaction load factor at Vsink = 3.05 m/s is below 3. Contact/impact force from simulation using MSC ADAMS is 94680 N, while using Solidworks Motion Analysis is 97691 N. The difference between MSC ADAMS and Solidworks Motion Analysis is 3.08%. The ground reaction load factor in MSC ADAMS is 2.78 while in Solidworks Motion Analysis is 2.87.
Likelihood-Based Confidence Intervals in Exploratory Factor Analysis
ERIC Educational Resources Information Center
Oort, Frans J.
2011-01-01
In exploratory or unrestricted factor analysis, all factor loadings are free to be estimated. In oblique solutions, the correlations between common factors are free to be estimated as well. The purpose of this article is to show how likelihood-based confidence intervals can be obtained for rotated factor loadings and factor correlations, by…
On the Relations among Regular, Equal Unique Variances, and Image Factor Analysis Models.
ERIC Educational Resources Information Center
Hayashi, Kentaro; Bentler, Peter M.
2000-01-01
Investigated the conditions under which the matrix of factor loadings from the factor analysis model with equal unique variances will give a good approximation to the matrix of factor loadings from the regular factor analysis model. Extends the results to the image factor analysis model. Discusses implications for practice. (SLD)
ERIC Educational Resources Information Center
Zhang, Guangjian; Preacher, Kristopher J.; Luo, Shanhong
2010-01-01
This article is concerned with using the bootstrap to assign confidence intervals for rotated factor loadings and factor correlations in ordinary least squares exploratory factor analysis. Coverage performances of "SE"-based intervals, percentile intervals, bias-corrected percentile intervals, bias-corrected accelerated percentile…
Perceptual load corresponds with factors known to influence visual search
Roper, Zachary J. J.; Cosman, Joshua D.; Vecera, Shaun P.
2014-01-01
One account of the early versus late selection debate in attention proposes that perceptual load determines the locus of selection. Attention selects stimuli at a late processing level under low-load conditions but selects stimuli at an early level under high-load conditions. Despite the successes of perceptual load theory, a non-circular definition of perceptual load remains elusive. We investigated the factors that influence perceptual load by using manipulations that have been studied extensively in visual search, namely target-distractor similarity and distractor-distractor similarity. Consistent with previous work, search was most efficient when targets and distractors were dissimilar and the displays contained homogeneous distractors; search became less efficient when target-distractor similarity increased irrespective of display heterogeneity. Importantly, we used these same stimuli in a typical perceptual load task that measured attentional spill-over to a task-irrelevant flanker. We found a strong correspondence between search efficiency and perceptual load; stimuli that generated efficient searches produced flanker interference effects, suggesting that such displays involved low perceptual load. Flanker interference effects were reduced in displays that produced less efficient searches. Furthermore, our results demonstrate that search difficulty, as measured by search intercept, has little bearing on perceptual load. These results suggest that perceptual load might be defined in part by well-characterized, continuous factors that influence visual search. PMID:23398258
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.
1979-01-01
A two dimensional, boundary collocation stress analysis was used to analyze various round compact specimens. The influence of the round external boundary and of pin-loaded holes on stress intensity factors and crack opening displacements was determined as a function of crack-length-to-specimen-width ratios. A wide-range equation for the stress intensity factors was developed. Equations for crack-surface displacements and load-point displacements were also developed. In addition, stress intensity factors were calculated from compliance methods to demonstrate that load-displacement records must be made at the loading points and not along the crack line for crack-length-to-specimen-width ratios less than about 0.4.
Performance of a cognitive load inventory during simulated handoffs: Evidence for validity.
Young, John Q; Boscardin, Christy K; van Dijk, Savannah M; Abdullah, Ruqayyah; Irby, David M; Sewell, Justin L; Ten Cate, Olle; O'Sullivan, Patricia S
2016-01-01
Advancing patient safety during handoffs remains a public health priority. The application of cognitive load theory offers promise, but is currently limited by the inability to measure cognitive load types. To develop and collect validity evidence for a revised self-report inventory that measures cognitive load types during a handoff. Based on prior published work, input from experts in cognitive load theory and handoffs, and a think-aloud exercise with residents, a revised Cognitive Load Inventory for Handoffs was developed. The Cognitive Load Inventory for Handoffs has items for intrinsic, extraneous, and germane load. Students who were second- and sixth-year students recruited from a Dutch medical school participated in four simulated handoffs (two simple and two complex cases). At the end of each handoff, study participants completed the Cognitive Load Inventory for Handoffs, Paas' Cognitive Load Scale, and one global rating item for intrinsic load, extraneous load, and germane load, respectively. Factor and correlational analyses were performed to collect evidence for validity. Confirmatory factor analysis yielded a single factor that combined intrinsic and germane loads. The extraneous load items performed poorly and were removed from the model. The score from the combined intrinsic and germane load items associated, as predicted by cognitive load theory, with a commonly used measure of overall cognitive load (Pearson's r = 0.83, p < 0.001), case complexity (beta = 0.74, p < 0.001), level of experience (beta = -0.96, p < 0.001), and handoff accuracy (r = -0.34, p < 0.001). These results offer encouragement that intrinsic load during handoffs may be measured via a self-report measure. Additional work is required to develop an adequate measure of extraneous load.
Factor Structure of the Penn State Worry Questionnaire: Examination of a Method Factor
ERIC Educational Resources Information Center
Hazlett-Stevens, Holly; Ullman, Jodie B.; Craske, Michelle G.
2004-01-01
The Penn State Worry Questionnaire (PSWQ) was originally designed as a unifactorial measure of pathological trait worry. However, recent studies supported a two-factor solution with positively worded items loading on the first factor and reverse-scored items loading on a second factor. The current study compared this two-factor model to a negative…
A VERSATILE FAMILY OF GALACTIC WIND MODELS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bustard, Chad; Zweibel, Ellen G.; D’Onghia, Elena, E-mail: bustard@wisc.edu
2016-03-01
We present a versatile family of model galactic outflows including non-uniform mass and energy source distributions, a gravitational potential from an extended mass source, and radiative losses. The model easily produces steady-state wind solutions for a range of mass-loading factors, energy-loading factors, galaxy mass, and galaxy radius. We find that, with radiative losses included, highly mass-loaded winds must be driven at high central temperatures, whereas low mass-loaded winds can be driven at low temperatures just above the peak of the cooling curve, meaning radiative losses can drastically affect the wind solution even for low mass-loading factors. By including radiative losses,more » we are able to show that subsonic flows can be ignored as a possible mechanism for expelling mass and energy from a galaxy compared to the more efficient transonic solutions. Specifically, the transonic solutions with low mass loading and high energy loading are the most efficient. Our model also produces low-temperature, high-velocity winds that could explain the prevalence of low-temperature material in observed outflows. Finally, we show that our model, unlike the well-known Chevalier and Clegg model, can reproduce the observed linear relationship between wind X-ray luminosity and star formation rate (SFR) over a large range of SFR from 1–1000 M{sub ⊙} yr{sup −1} assuming the wind mass-loading factor is higher for low-mass, and hence, low-SFR galaxies. We also constrain the allowed mass-loading factors that can fit the observed X-ray luminosity versus SFR trend, further suggesting an inverse relationship between mass loading and SFR as explored in advanced numerical simulations.« less
LRFD Resistance Factor Calibration for Axially Loaded Drilled Shafts in the Las Vegas Valley
DOT National Transportation Integrated Search
2016-07-19
Resistance factors for LRFD of axially loaded drilled shafts in the Las Vegas Valley are calibrated using data from 41 field load tests. In addition to the traditional implementation of Monte Carlo (MC) simulations for calibration, a more robust tech...
Evaluation of LADOTD traffic load data for determination of traffic load equivalency factors.
DOT National Transportation Integrated Search
2001-07-01
This study updates Louisiana's Load Equivalency Factor (LEF) tables, which are used as an integral part of the State's highway design and rehabilitation effort. This study was required because the tables have not been updated in over 15 years and are...
Crack growth induced by thermal-mechanical loading
NASA Astrophysics Data System (ADS)
John, R.; Hartman, G. A.; Gallagher, J. P.
1992-06-01
Advanced aerospace structures are often subjected to combined thermal and mechanical loads. The fracture-mechanics behavior of the structures may be altered by the thermal state existing around the crack. Hence, design of critical structural elements requires the knowledge of stress-intensity factors under both thermal and mechanical loads. This paper describes the development of an experimental technique to verify the thermal-stress-intensity factor generated by a temperature gradient around the crack. Thin plate specimens of a model material (AISI-SAE 1095 steel) were used for the heat transfer and thermal-mechanical fracture tests. Rapid thermal loading was achieved using high-intensity focused infrared spot heaters. These heaters were also used to generate controlled temperature rates for heat-transfer verification tests. The experimental results indicate that thermal loads can generate stress-intensity factors large enough to induce crack growth. The proposed thermal-stress-intensity factors appear to have the same effect as the conventional mechanical-stress-intensity factors with respect to fracture.
2014-09-01
peak shaving, conducting power factor correction, matching critical load to most efficient distributed resource, and islanding a system during...photovoltaic arrays during islanding, and power factor correction, the implementation of the ESS by itself is likely to prove cost prohibitive. The DOD...These functions include peak shaving, conducting power factor correction, matching critical load to most efficient distributed resource, and islanding a
Resistance factors for 100% dynamic testing, with and without static load tests.
DOT National Transportation Integrated Search
2011-05-01
Current department of transportation (DOT) and Federal Highway Administration (FHWA) practice has highly : variable load and resistance factor design (LRFD) resistance factors, , for driven piles from design (e.g., Standard : Penetration Tests (SPT...
The Role of Cardiovascular Risk Factors and Stroke in Familial Alzheimer Disease.
Tosto, Giuseppe; Bird, Thomas D; Bennett, David A; Boeve, Bradley F; Brickman, Adam M; Cruchaga, Carlos; Faber, Kelley; Foroud, Tatiana M; Farlow, Martin; Goate, Alison M; Graff-Radford, Neill R; Lantigua, Rafael; Manly, Jennifer; Ottman, Ruth; Rosenberg, Roger; Schaid, Daniel J; Schupf, Nicole; Stern, Yaakov; Sweet, Robert A; Mayeux, Richard
2016-10-01
The contribution of cardiovascular disease (CV) and cerebrovascular disease to the risk for late-onset Alzheimer disease (LOAD) has been long debated. Investigations have shown that antecedent CV risk factors increase the risk for LOAD, although other investigations have failed to validate this association. To study the contribution of CV risk factors (type 2 diabetes, hypertension, and heart disease) and the history of stroke to LOAD in a data set of large families multiply affected by LOAD. The National Institute on Aging Late-Onset Alzheimer Disease/National Cell Repository for Alzheimer Disease family study (hereinafter referred to as NIA-LOAD study) is a longitudinal study of families with multiple members affected with LOAD. A multiethnic community-based longitudinal study (Washington Heights-Inwood Columbia Aging Project [WHICAP]) was used to replicate findings. The 6553 participants in the NIA-LOAD study were recruited from 23 US Alzheimer disease centers with ongoing data collection since 2003; the 5972 WHICAP participants were recruited at Columbia University with ongoing data collection since 1992. Data analysis was performed from 2003 to 2015. Generalized mixed logistic regression models tested the association of CV risk factors (primary association) with LOAD. History of stroke was used for the secondary association. A secondary model adjusted for the presence of an apolipoprotein E (APOE) ε4 allele. A genetic risk score, based on common variants associated with LOAD, was used to account for LOAD genetic risk beyond the APOE ε4 effect. Mediation analyses evaluated stroke as a mediating factor between the primary association and LOAD. A total of 6553 NIA-LOAD participants were included in the analyses (4044 women [61.7%]; 2509 men [38.3%]; mean [SD] age, 77.0 [9] years), with 5972 individuals from the WHICAP study included in the replication sample (4072 women [68.2%]; 1900 men [31.8%]; mean [SD] age, 76.5 [7.0] years). Hypertension was associated with decreased LOAD risk (odds ratio [OR], 0.63; 95% CI, 0.55-0.72); type 2 diabetes and heart disease were not. History of stroke conferred greater than 2-fold increased risk for LOAD (OR, 2.23; 95% CI, 1.75-2.83). Adjustment for APOE ε4 did not alter results. The genetic risk score was associated with LOAD (OR, 2.85; 95% CI, 2.05-3.97) but did not change the independent association of LOAD with hypertension or stroke. In the WHICAP sample, hypertension was not associated with LOAD (OR, 0.99; 95% CI, 0.88-1.11), whereas history of stroke increased the risk for LOAD (OR, 1.96; 95% CI, 1.56-2.46). The effect of hypertension on LOAD risk was also mediated by stroke in the NIA-LOAD and the WHICAP samples. In familial and sporadic LOAD, a history of stroke was significantly associated with increased disease risk and mediated the association between selected CV risk factors and LOAD, which appears to be independent of the LOAD-related genetic background.
The Role of Cardiovascular Risk Factors and Stroke in Familial Alzheimer Disease
Tosto, Giuseppe; Bird, Thomas D.; Bennett, David A.; Boeve, Bradley F.; Brickman, Adam M.; Cruchaga, Carlos; Faber, Kelley; Foroud, Tatiana M.; Farlow, Martin; Goate, Alison M.; Graff-Radford, Neill R.; Lantigua, Rafael; Manly, Jennifer; Ottman, Ruth; Rosenberg, Roger; Schaid, Daniel J.; Schupf, Nicole; Stern, Yaakov; Sweet, Robert A.; Mayeux, Richard
2016-01-01
Importance The contribution of cardiovascular disease (CV) and cerebrovascular disease to the risk for late-onset Alzheimer disease (LOAD) has been long debated. Investigations have shown that antecedent CV risk factors increase the risk for LOAD, although other investigations have failed to validate this association. Objective To study the contribution of CV risk factors (type 2 diabetes, hypertension, and heart disease) and the history of stroke to LOAD in a data set of large families multiply affected by LOAD. Design, Setting, and Participants The National Institute on Aging Late-Onset Alzheimer Disease/National Cell Repository for Alzheimer Disease family study (hereinafter referred to as NIA-LOAD study) is a longitudinal study of families with multiple members affected with LOAD. A multiethnic community-based longitudinal study (Washington Heights–Inwood Columbia Aging Project [WHICAP]) was used to replicate findings. The 6553 participants in the NIA-LOAD study were recruited from 23 US Alzheimer disease centers with ongoing data collection since 2003; the 5972 WHICAP participants were recruited at Columbia University with ongoing data collection since 1992. Data analysis was performed from 2003 to 2015. Main Outcomes and Measures Generalized mixed logistic regression models tested the association of CV risk factors (primary association) with LOAD. History of stroke was used for the secondary association. A secondary model adjusted for the presence of an apolipoprotein E (APOE) ε4 allele. A genetic risk score, based on common variants associated with LOAD, was used to account for LOAD genetic risk beyond the APOE ε4 effect. Mediation analyses evaluated stroke as a mediating factor between the primary association and LOAD. Results A total of 6553 NIA-LOAD participants were included in the analyses (4044 women [61.7%]; 2509 men [38.3%]; mean [SD] age, 77.0 [9] years), with 5972 individuals from the WHICAP study included in the replication sample (4072 women [68.2%]; 1900 men [31.8%]; mean [SD] age, 76.5 [7.0] years). Hypertension was associated with decreased LOAD risk (odds ratio [OR], 0.63; 95% CI, 0.55-0.72); type 2 diabetes and heart disease were not. History of stroke conferred greater than 2-fold increased risk for LOAD (OR, 2.23; 95% CI, 1.75-2.83). Adjustment for APOE ε4 did not alter results. The genetic risk score was associated with LOAD (OR, 2.85; 95% CI, 2.05-3.97) but did not change the independent association of LOAD with hypertension or stroke. In the WHICAP sample, hypertension was not associated with LOAD (OR, 0.99; 95% CI, 0.88-1.11), whereas history of stroke increased the risk for LOAD (OR, 1.96; 95% CI, 1.56-2.46). The effect of hypertension on LOAD risk was also mediated by stroke in the NIA-LOAD and the WHICAP samples. Conclusions and Relevance In familial and sporadic LOAD, a history of stroke was significantly associated with increased disease risk and mediated the association between selected CV risk factors and LOAD, which appears to be independent of the LOAD-related genetic background. PMID:27533593
Factor Analysis via Components Analysis
ERIC Educational Resources Information Center
Bentler, Peter M.; de Leeuw, Jan
2011-01-01
When the factor analysis model holds, component loadings are linear combinations of factor loadings, and vice versa. This interrelation permits us to define new optimization criteria and estimation methods for exploratory factor analysis. Although this article is primarily conceptual in nature, an illustrative example and a small simulation show…
What is the relationship between mental workload factors and cognitive load types?
Galy, Edith; Cariou, Magali; Mélan, Claudine
2012-03-01
The present study tested the hypothesis of an additive interaction between intrinsic, extraneous and germane cognitive load, by manipulating factors of mental workload assumed to have a specific effect on either type of cognitive load. The study of cognitive load factors and their interaction is essential if we are to improve workers' wellbeing and safety at work. High cognitive load requires the individual to allocate extra resources to entering information. It is thought that this demand for extra resources may reduce processing efficiency and performance. The present study tested the effects of three factors thought to act on either cognitive load type, i.e. task difficulty, time pressure and alertness in a working memory task. Results revealed additive effects of task difficulty and time pressure, and a modulation by alertness on behavioral, subjective and psychophysiological workload measures. Mental overload can be the result of a combination of task-related components, but its occurrence may also depend on subject-related characteristics, including alertness. Solutions designed to reduce incidents and accidents at work should consider work organization in addition to task constraints in so far that both these factors may interfere with mental workload. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Saraswat, S. K.; Rao, K. V. S.
2018-03-01
Jaisalmer town in Rajasthan, India is having annual average solar insolation of 5.80 kWh/m2/day and 270 – 300 clear sky days in a year. A 10 kW off-grid hybrid energy system (HES) consisting of solar photovoltaic panels – diesel generator – bidirectional converter and batteries with zero percentage loss of load for Jaisalmer is designed using HOMER (version 3.4.3) software. Different system load factors of 0.33, 0.50, 0.67, 0.83 and 1 corresponding to fraction of running hours per day of the system are considered. The system is analyzed for all three aspects, namely, electrical, economic and emission point of view. Least levelized cost of electricity (LCOE) of Rs. 8.43/kWh is obtained at a load factor value of 0.5. If diesel generator alone (without Solar PV) is used to fulfil the demand for a load factor of 0.5the value of LCOE is obtained Rs.19.23/kWh. Comparison of results obtained for HES and diesel generator are made for load factor of 0.5 and 1.
Code of Federal Regulations, 2010 CFR
2010-01-01
... significantly change the distribution of external or internal loads, this redistribution must be taken into... loads multiplied by prescribed factors of safety). Unless otherwise provided, prescribed loads are limit...
Perceptual load corresponds with factors known to influence visual search.
Roper, Zachary J J; Cosman, Joshua D; Vecera, Shaun P
2013-10-01
One account of the early versus late selection debate in attention proposes that perceptual load determines the locus of selection. Attention selects stimuli at a late processing level under low-load conditions but selects stimuli at an early level under high-load conditions. Despite the successes of perceptual load theory, a noncircular definition of perceptual load remains elusive. We investigated the factors that influence perceptual load by using manipulations that have been studied extensively in visual search, namely target-distractor similarity and distractor-distractor similarity. Consistent with previous work, search was most efficient when targets and distractors were dissimilar and the displays contained homogeneous distractors; search became less efficient when target-distractor similarity increased irrespective of display heterogeneity. Importantly, we used these same stimuli in a typical perceptual load task that measured attentional spillover to a task-irrelevant flanker. We found a strong correspondence between search efficiency and perceptual load; stimuli that generated efficient searches produced flanker interference effects, suggesting that such displays involved low perceptual load. Flanker interference effects were reduced in displays that produced less efficient searches. Furthermore, our results demonstrate that search difficulty, as measured by search intercept, has little bearing on perceptual load. We conclude that rather than be arbitrarily defined, perceptual load might be defined by well-characterized, continuous factors that influence visual search. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Relationship between current load and temperature for quasi-steady state and transient conditions
NASA Astrophysics Data System (ADS)
Lyon, Bernard R., Jr.; Orlove, Gary L.; Peters, Donna L.
2000-03-01
Infrared thermographers involved in predictive maintenance programs often use temperature measurement as a means of quantifying the severity of a problem. Temperature is certainly an important factor in evaluating equipment. However, if you follow guidelines that are based solely on absolute temperature measurement--or on a temperature rise (Delta T)--you run the risk of incorrectly diagnosing your problems. The consequences of such actions can lead to a false sense of security, equipment failure, fire, and even the possibility of personal injury. Understanding the additional factors involved in diagnosis is essential for obtaining productive results. One of these factors is the load or current flowing through conductors. The load can have a drastic effect on the temperature of a component. Changing loads can cause additional concerns because temperature changes lag behind load changes. The purpose of this paper is to illustrate the relationship between load and temperature of a faulty connection. The thermal response of a changing load is also investigated.
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Zaretsky, Erwin V.; Poplawski, Joseph V.
2012-01-01
The effect of internal clearance on radially loaded deepgroove ball and cylindrical roller bearing load distribution and fatigue life was determined for four clearance groups defined in the bearing standards. The analysis was extended to negative clearance (interference) conditions to produce a curve of life factor versus internal clearance. Rolling-element loads can be optimized and bearing life maximized for a small negative operating clearance. Life declines gradually with positive clearance and rapidly with increasing negative clearance. Relationships were found between bearing life and internal clearance as a function of ball or roller diameter, adjusted for load. Results are presented as life factors for radially loaded bearings independent of bearing size or applied load. In addition, a modified Stribeck Equation is presented that relates the maximum rolling-element load to internal bearing clearance.
Predicted effect of dynamic load on pitting fatigue life for low-contact-ratio spur gears
NASA Technical Reports Server (NTRS)
Lewicki, David G.
1986-01-01
How dynamic load affects the surface pitting fatigue life of external spur gears was predicted by using the NASA computer program TELSGE. Parametric studies were performed over a range of various gear parameters modeling low-contact-ratio involute spur gears. In general, gear life predictions based on dynamic loads differed significantly from those based on static loads, with the predictions being strongly influenced by the maximum dynamic load during contact. Gear mesh operating speed strongly affected predicted dynamic load and life. Meshes operating at a resonant speed or one-half the resonant speed had significantly shorter lives. Dynamic life factors for gear surface pitting fatigue were developed on the basis of the parametric studies. In general, meshes with higher contact ratios had higher dynamic life factors than meshes with lower contact ratios. A design chart was developed for hand calculations of dynamic life factors.
Prasant, M C; Thukral, Rishi; Kumar, Sachin; Sadrani, Sannishth M; Baxi, Harsh; Shah, Aditi
2016-10-01
Ever since its introduction in 1977, a minimum of few months of period is required for osseointegration to take place after dental implant surgery. With the passage of time and advancements in the fields of dental implant, this healing period is getting smaller and smaller. Immediate loading of dental implants is becoming a very popular procedure in the recent time. Hence, we retrospectively analyzed the various risk factors for the failure of delayed and immediate loaded dental implants. In the present study, retrospective analysis of all the patients was done who underwent dental implant surgeries either by immediate loading procedure or by delayed loading procedures. All the patients were divided broadly into two groups with one group containing patients in which delayed loaded dental implants were placed while other consisted of patients in whom immediate loaded dental implants were placed. All the patients in whom follow-up records were missing and who had past medical history of any systemic diseases were excluded from the present study. Evaluation of associated possible risk factors was done by classifying the predictable factors as primary and secondary factors. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. Kaplan-Meier survival analyses and chi-square test were used for assessment of level of significance. In delayed and immediate group of dental implants, mean age of the patients was 54.2 and 54.8 years respectively. Statistically significant results were obtained while comparing the clinical parameters of the dental implants in both the groups while demographic parameters showed nonsignificant correlation. Significant higher risk of dental implant failure is associated with immediate loaded dental implants. Tobacco smoking, shorter implant size, and other risk factors play a significant role in predicting the success and failure of dental implants. Delayed loaded dental implant placement should be preferred as they are associated with decreased risk of implant failure.
NASA Technical Reports Server (NTRS)
Binienda, Wieslaw K.; Roberts, Gary D.; Papadopoulos, Demetrios S.
1992-01-01
The results of in-plane four-point bend experiments on unidirectionally reinforced composite beams are presented for graphite/epoxy (T300/934) and graphite/polyimide (G30-500/PMR-15) composites. The maximum load and the location of cracks formed during failure were measured for testpieces with fibers oriented at various angles to the beam axis. Since most of the beams failed near one or more of the load points, the strength of the beams was evaluated in terms of a proposed model, for the local stress distribution. In this model, an exact solution to the problem of a localized contact force acting on a unidirectionally reinforced half plane is used to describe the local stress field. The stress singularity at the load points is treated in a manner similar to the stress singularity at a crack tip in fracture mechanisms problems. Using this approach, the effect of fiber angle and elastic material properties on the strength of the beam is described in terms of a load intensity factor. For fiber angles less than 45 deg from the beam axis, a single crack is initiated near one of the load points at a critical value of the load intensity factor. The critical load intensity factor decreases with the increasing fiber angle. For larger fiber angles, multiple cracks occur at locations both near and away from the load points, and the load intensity factor at failure increases sharply with increasing fiber angle.
NASA Technical Reports Server (NTRS)
Binienda, W. K.; Roberts, G. D.; Papadopoulos, D. S.
1992-01-01
The results of in-plane four-point bend experiments on unidirectionally reinforced composite beams are presented for graphite/epoxy (T300/934) and graphite/polyimide (G30-500/PMR-15) composites. The maximum load and the location of cracks formed during failure were measured for testpieces with fibers oriented at various angles to the beam axis. Since most of the beams failed near one or more of the load points, the strength of the beams was evaluated in terms of a proposed model for the local stress distribution. In this model, an exact solution to the problem of a localized contact force acting on a unidirectionally reinforced half plane is used to describe the local stress field. The stress singularity at the load points is treated in a manner similar to the stress singularity at a crack tip in fracture mechanisms problems. Using this approach, the effect of fiber angle and elastic material properties on the strength of the beam is described in terms of a load intensity factor. For fiber angles less than 45 deg from the beam axis, a single crack is initiated near one of the load points at a critical value of the load intensity factor. The critical load intensity factor decreases with increasing fiber angle. For larger fiber angles, multiple cracks occur at locations both near and away from the load points, and the load intensity factor at failure increases sharply with increasing fiber angle.
ERIC Educational Resources Information Center
Major, Jason T.; Johnson, Wendy; Bouchard, Thomas J., Jr.
2011-01-01
Floyd, Shands, Rafael, Bergeron and McGrew (2009) used generalizability theory to test the reliability of general-factor loadings and to compare three different sources of error in them: the test battery size, the test battery composition, the factor-extraction technique, and their interactions. They found that their general-factor loadings were…
Quantitative evolutionary design
Diamond, Jared
2002-01-01
The field of quantitative evolutionary design uses evolutionary reasoning (in terms of natural selection and ultimate causation) to understand the magnitudes of biological reserve capacities, i.e. excesses of capacities over natural loads. Ratios of capacities to loads, defined as safety factors, fall in the range 1.2-10 for most engineered and biological components, even though engineered safety factors are specified intentionally by humans while biological safety factors arise through natural selection. Familiar examples of engineered safety factors include those of buildings, bridges and elevators (lifts), while biological examples include factors of bones and other structural elements, of enzymes and transporters, and of organ metabolic performances. Safety factors serve to minimize the overlap zone (resulting in performance failure) between the low tail of capacity distributions and the high tail of load distributions. Safety factors increase with coefficients of variation of load and capacity, with capacity deterioration with time, and with cost of failure, and decrease with costs of initial construction, maintenance, operation, and opportunity. Adaptive regulation of many biological systems involves capacity increases with increasing load; several quantitative examples suggest sublinear increases, such that safety factors decrease towards 1.0. Unsolved questions include safety factors of series systems, parallel or branched pathways, elements with multiple functions, enzyme reaction chains, and equilibrium enzymes. The modest sizes of safety factors imply the existence of costs that penalize excess capacities. Those costs are likely to involve wasted energy or space for large or expensive components, but opportunity costs of wasted space at the molecular level for minor components. PMID:12122135
ERIC Educational Resources Information Center
Reynolds, Matthew R.
2013-01-01
The linear loadings of intelligence test composite scores on a general factor ("g") have been investigated recently in factor analytic studies. Spearman's law of diminishing returns (SLODR), however, implies that the "g" loadings of test scores likely decrease in magnitude as g increases, or they are nonlinear. The purpose of…
Load assumptions for the landing impact of seaplanes
NASA Technical Reports Server (NTRS)
Taub, Josef
1931-01-01
The formula for the impact of floats must include the enlargement factor itself as well as the type of enlargement. The latter is preferably characterized by the change in surface loading. It is shown that the enlargement of a small seaplane generally results in a changed float (or boat) loading as well as wing loading. The conditions of starting stipulate the retention of the float loading when changing from single-float (boat) to twin-float arrangement. This contingency is followed by an increased impact factor in the twin-float type against the otherwise equivalent single-float type.
Platelet-independent adhesion of calcium-loaded erythrocytes to von Willebrand factor
Bierings, Ruben; Meems, Henriet; Mul, Frederik P. J.; Geerts, Dirk; Vlaar, Alexander P. J.; Voorberg, Jan; Hordijk, Peter L.
2017-01-01
Adhesion of erythrocytes to endothelial cells lining the vascular wall can cause vaso-occlusive events that impair blood flow which in turn may result in ischemia and tissue damage. Adhesion of erythrocytes to vascular endothelial cells has been described in multiple hemolytic disorders, especially in sickle cell disease, but the adhesion of normal erythrocytes to endothelial cells has hardly been described. It was shown that calcium-loaded erythrocytes can adhere to endothelial cells. Because sickle erythrocyte adhesion to ECs can be enhanced by ultra-large von Willebrand factor multimers, we investigated whether calcium loading of erythrocytes could promote binding to endothelial cells via ultra-large von Willebrand factor multimers. We used (immunofluorescent) live-cell imaging of washed erythrocytes perfused over primary endothelial cells at venular flow rate. Using this approach, we show that calcium-loaded erythrocytes strongly adhere to histamine-stimulated primary human endothelial cells. This adhesion is mediated by ultra-large von Willebrand factor multimers. Von Willebrand factor knockdown or ADAMTS13 cleavage abolished the binding of erythrocytes to activated endothelial cells under flow. Platelet depletion did not interfere with erythrocyte binding to von Willebrand factor. Our results reveal platelet-independent adhesion of calcium-loaded erythrocytes to endothelium-derived von Willebrand factor. Erythrocyte adhesion to von Willebrand factor may be particularly relevant for venous thrombosis, which is characterized by the formation of erythrocyte-rich thrombi. PMID:28249049
NASA Technical Reports Server (NTRS)
Quade, D. A.
1978-01-01
The airplane flutter and maneuver-gust load analysis results obtained during B-52B drop test vehicle configuration (with fins) evaluation are presented. These data are presented as supplementary data to that given in Volume 1 of this document. A brief mathematical description of airspeed notation and gust load factor criteria are provided as a help to the user. References are defined which provide mathematical description of the airplane flutter and load analysis techniques. Air-speed-load factor diagrams are provided for the airplane weight configurations reanalyzed for finned drop test vehicle configuration.
Factor structure of the Hooper Visual Organization Test: a cross-cultural replication and extension.
Merten, Thomas
2005-01-01
To investigate construct validity of the Hooper Visual Organization Test (VOT), a principal-axis analysis was performed on the neuropsychological test results of 200 German-speaking neurological patients who received a comprehensive battery, encompassing tests of visuospatial functions, memory, attention, executive functions, naming ability, and vocabulary. A four-factor solution was obtained with substantial loadings of the VOT only on the first factor, interpreted as a global dimension of non-verbal cognitive functions. This factor loaded significantly on numerous measures of visuospatial processing and attention (with particularly high loadings on WAIS-R Block Design, Trails A and B, and Raven's Standard Progressive Matrices). The remaining three factors were interpreted as memory, verbal abilities (vocabulary), and a separate factor of naming abilities.
Confirmatory Factor Analysis of the Delirium Rating Scale Revised-98 (DRS-R98).
Thurber, Steven; Kishi, Yasuhiro; Trzepacz, Paula T; Franco, Jose G; Meagher, David J; Lee, Yanghyun; Kim, Jeong-Lan; Furlanetto, Leticia M; Negreiros, Daniel; Huang, Ming-Chyi; Chen, Chun-Hsin; Kean, Jacob; Leonard, Maeve
2015-01-01
Principal components analysis applied to the Delirium Rating Scale-Revised-98 contributes to understanding the delirium construct. Using a multisite pooled international delirium database, the authors applied confirmatory factor analysis to Delirium Rating Scale-Revised-98 scores from 859 adult patients evaluated by delirium experts (delirium, N=516; nondelirium, N=343). Confirmatory factor analysis found all diagnostic features and core symptoms (cognitive, language, thought process, sleep-wake cycle, motor retardation), except motor agitation, loaded onto factor 1. Motor agitation loaded onto factor 2 with noncore symptoms (delusions, affective lability, and perceptual disturbances). Factor 1 loading supports delirium as a single construct, but when accompanied by psychosis, motor agitation's role may not be solely as a circadian activity indicator.
Qinqin, Li; Qiao, Chen; Jiancai, Deng; Weiping, Hu
2015-01-01
An understanding of the characteristics of pollutants on impervious surfaces is essential to estimate pollution loads and to design methods to minimize the impacts of pollutants on the environment. In this study, simulated rainfall equipment was constructed to investigate the pollutant discharge process and the influence factors of urban surface runoff (USR). The results indicated that concentrations of total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP) and chemical oxygen demand (COD) appeared to be higher in the early period and then decreased gradually with rainfall duration until finally stabilized. The capacity and particle size of surface dust, rainfall intensity and urban surface slopes affected runoff pollution loads to a variable extent. The loads of TP, TN and COD showed a positive relationship with the surface dust capacity, whereas the maximum TSS load appeared when the surface dust was 0.0317 g·cm⁻². Smaller particle sizes (<0.125 mm) of surface dust generated high TN, TP and COD loads. Increases in rainfall intensity and surface slope enhanced the pollution carrying capacity of runoff, leading to higher pollution loads. Knowledge of the influence factors could assist in the management of USR pollution loads.
This paper summarizes an ongoing examination of the primary factors that affect sensitivity of marine embayment responses to nitrogen loading. Included is a discussion of two methods for using these factors: classification of embayments into discrete sensitivity classes and norma...
DOT National Transportation Integrated Search
2011-07-01
For pavement design practices, several factors must be considered to ensure good pavement performance over the anticipated life cycle. : Such factors include, but are not limited to, the type of paving materials, traffic loading characteristics, prev...
1994-06-03
transport , the effects of technology, terrain and weather, and physical conditioning. Load, Soidier’s Load, Rucksack, Physical Conditioning, Combat Load...Fighting Load, Sustainment Load, Approach March Load, Fear, Fatigue, Risk, Training, Transport , Techn-logy UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED I .1 THE...standards, myths of peacetime training, the nature of the soldier, lack of transport , the effects of technology, terrain and weather, and physical
1989-05-01
also drawn up by Vereinigte Flugtech- nischen Werken as a technoeconomic analysis . The aerospace industry will be looking for the following...ultimate load without rupture. These conditions are verified by analysis and test. The limit load is the maximum load the vehicle is expected to see...the uncertainty factor (formerly known as the factor of safety) which accounts for variations in manufacture, defects not assumed in analysis but
NASA Astrophysics Data System (ADS)
Qiu, Yunfei; Li, Xizhong; Zheng, Wei; Hu, Qinghe; Wei, Zhanmeng; Yue, Yaqin
2017-08-01
The climate changes have great impact on the residents’ electricity consumption, so the study on the impact of climatic factors on electric power load is of significance. In this paper, the effects of the data of temperature, rainfall and wind of smart city on short-term power load is studied to predict power load. The authors studied the relation between power load and daily temperature, rainfall and wind in the 31 days of January of one year. In the research, the authors used the Matlab neural network toolbox to establish the combinational forecasting model. The authors trained the original input data continuously to get the internal rules inside the data and used the rules to predict the daily power load in the next January. The prediction method relies on the accuracy of weather forecasting. If the weather forecasting is different from the actual weather, we need to correct the climatic factors to ensure accurate prediction.
NASA Astrophysics Data System (ADS)
Chen, Rong; Li, Kang; Xia, Kaiwen; Lin, Yuliang; Yao, Wei; Lu, Fangyun
2016-10-01
A dynamic load superposed on a static pre-load is a key problem in deep underground rock engineering projects. Based on a modified split Hopkinson pressure bar test system, the notched semi-circular bend (NSCB) method is selected to investigate the fracture initiation toughness of rocks subjected to pre-load. In this study, a two-dimensional ANSYS finite element simulation model is developed to calculate the dimensionless stress intensity factor. Three groups of NSCB specimen are tested under a pre-load of 0, 37 and 74 % of the maximum static load and with the loading rate ranging from 0 to 60 GPa m1/2 s-1. The results show that under a given pre-load, the fracture initiation toughness of rock increases with the loading rate, resembling the typical rate dependence of materials. Furthermore, the dynamic rock fracture toughness decreases with the static pre-load at a given loading rate. The total fracture toughness, defined as the sum of the dynamic fracture toughness and initial stress intensity factor calculated from the pre-load, increases with the pre-load at a given loading rate. An empirical equation is used to represent the effect of loading rate and pre-load force, and the results show that this equation can depict the trend of the experimental data.
40 CFR Table 33 to Subpart G of... - Saturation Factors
Code of Federal Regulations, 2011 CFR
2011-07-01
... service 0.60 Submerged loading: dedicated vapor balance service 1.00 Splash loading of a clean cargo tank 1.45 Splash loading: dedicated normal service 1.45 Splash loading: dedicated vapor balance service 1...
40 CFR Table 33 to Subpart G of... - Saturation Factors
Code of Federal Regulations, 2014 CFR
2014-07-01
... service 0.60 Submerged loading: dedicated vapor balance service 1.00 Splash loading of a clean cargo tank 1.45 Splash loading: dedicated normal service 1.45 Splash loading: dedicated vapor balance service 1...
40 CFR Table 33 to Subpart G of... - Saturation Factors
Code of Federal Regulations, 2012 CFR
2012-07-01
... service 0.60 Submerged loading: dedicated vapor balance service 1.00 Splash loading of a clean cargo tank 1.45 Splash loading: dedicated normal service 1.45 Splash loading: dedicated vapor balance service 1...
40 CFR Table 33 to Subpart G of... - Saturation Factors
Code of Federal Regulations, 2010 CFR
2010-07-01
... service 0.60 Submerged loading: dedicated vapor balance service 1.00 Splash loading of a clean cargo tank 1.45 Splash loading: dedicated normal service 1.45 Splash loading: dedicated vapor balance service 1...
40 CFR Table 33 to Subpart G of... - Saturation Factors
Code of Federal Regulations, 2013 CFR
2013-07-01
... service 0.60 Submerged loading: dedicated vapor balance service 1.00 Splash loading of a clean cargo tank 1.45 Splash loading: dedicated normal service 1.45 Splash loading: dedicated vapor balance service 1...
Experimental Investigations on Axially and Eccentrically Loaded Masonry Walls
NASA Astrophysics Data System (ADS)
Keshava, Mangala; Raghunath, Seshagiri Rao
2017-12-01
In India, un-reinforced masonry walls are often used as main structural components in load bearing structures. Indian code on masonry accounts the reduction in strength of walls by using stress reduction factors in its design philosophy. This code was introduced in 1987 and reaffirmed in 1995. The present study investigates the use of these factors for south Indian masonry. Also, with the gaining popularity in block work construction, the aim of this study was to find out the suitability of these factors given in the Indian code to block work masonry. Normally, the load carrying capacity of masonry walls can be assessed in three ways, namely, (1) tests on masonry constituents, (2) tests on masonry prisms and (3) tests on full-scale wall specimens. Tests on bricks/blocks, cement-sand mortar, brick/block masonry prisms and 14 full-scale brick/block masonry walls formed the experimental investigation. The behavior of the walls was investigated under varying slenderness and eccentricity ratios. Hollow concrete blocks normally used as in-fill masonry can be considered as load bearing elements as its load carrying capacity was found to be high when compared to conventional brick masonry. Higher slenderness and eccentricity ratios drastically reduced the strength capacity of south Indian brick masonry walls. The reduction in strength due to slenderness and eccentricity is presented in the form of stress reduction factors in the Indian code. These factors obtained through experiments on eccentrically loaded brick masonry walls was lower while that of brick/block masonry under axial loads was higher than the values indicated in the Indian code. Also the reduction in strength is different for brick and block work masonry thus indicating the need for separate stress reduction factors for these two masonry materials.
Microgrid Study: Energy Security for DoD Installations
2012-06-18
security, efficiency, and the incorporation of renewable and distributed energy resources into microgrids, as well as the factors that might facilitate...better understand how different environmental factors affected the choice of optimal microgrid architecture. Environmental factors in this context...lower costs—Networking generation assets allow for load sharing, allowing fewer generators to run at higher load factors and therefore with greater
Load Distribution Factors for Composite Multicell Box Girder Bridges
NASA Astrophysics Data System (ADS)
Tiwari, Sanjay; Bhargava, Pradeep
2017-12-01
Cellular steel section composite with a concrete deck is one of the most suitable superstructures in resisting torsional and warping effects induced by highway loading. This type of structure has inherently created new design problems for engineers in estimating its load distribution when subjected to moving vehicles. Indian Codes of Practice does not provide any specific guidelines for the design of straight composite concrete deck-steel multi-cell bridges. To meet the practical requirements arising during the design process, a simple design method is needed for straight composite multi-cell bridges in the form of load distribution factors for moment and shear. This work presents load distribution characteristics of straight composite multi-cell box girder bridges under IRC trains of loads.
A Fatigue Life Prediction Method Based on Strain Intensity Factor
Zhang, Wei; Liu, Huili; Wang, Qiang; He, Jingjing
2017-01-01
In this paper, a strain-intensity-factor-based method is proposed to calculate the fatigue crack growth under the fully reversed loading condition. A theoretical analysis is conducted in detail to demonstrate that the strain intensity factor is likely to be a better driving parameter correlated with the fatigue crack growth rate than the stress intensity factor (SIF), especially for some metallic materials (such as 316 austenitic stainless steel) in the low cycle fatigue region with negative stress ratios R (typically R = −1). For fully reversed cyclic loading, the constitutive relation between stress and strain should follow the cyclic stress-strain curve rather than the monotonic one (it is a nonlinear function even within the elastic region). Based on that, a transformation algorithm between the SIF and the strain intensity factor is developed, and the fatigue crack growth rate testing data of 316 austenitic stainless steel and AZ31 magnesium alloy are employed to validate the proposed model. It is clearly observed that the scatter band width of crack growth rate vs. strain intensity factor is narrower than that vs. the SIF for different load ranges (which indicates that the strain intensity factor is a better parameter than the stress intensity factor under the fully reversed load condition). It is also shown that the crack growth rate is not uniquely determined by the SIF range even under the same R, but is also influenced by the maximum loading. Additionally, the fatigue life data (strain-life curve) of smooth cylindrical specimens are also used for further comparison, where a modified Paris equation and the equivalent initial flaw size (EIFS) are involved. The results of the proposed method have a better agreement with the experimental data compared to the stress intensity factor based method. Overall, the strain intensity factor method shows a fairly good ability in calculating the fatigue crack propagation, especially for the fully reversed cyclic loading condition. PMID:28773049
Tanaka, Kaori; Hori, Tsukasa; Hatakeyama, Naoki; Yamamoto, Masaki; Takayama, Rumiko; Yoto, Yuko; Suzuki, Nobuhiro; Hayashi, Toshiaki; Ikeda, Yukiho; Ikeda, Hiroshi; Ishida, Tadao; Tsutsumi, Hiroyuki
2008-12-01
Polyoma BK virus (BKV) is frequently found in the urine of stem cell transplantation (SCT) patients with hemorrhagic cystitis (HC), but also occurs in SCT patients without HC. How BK viruria relates to the development of HC in SCT patients, especially in children, has not yet been fully evaluated. In the present study, we analyzed the relationship of several factors including urinary BKV load to HC development in children and adults undergoing SCT. We employed a quantitative PCR assay and evaluated 37 patients (aged 9 months-62 years) of whom 12 developed HC and 25 did not. Older age was a risk factor for the development of HC; however, other factors such as sex, primary disease, type of SCT, conditioning regimen and aGVHD were not. Peak urinary BKV values in HC patients were not higher than those in non-HC patients. Severity of HC also did not correlate with urinary BKV loads. However, in some patients who secreted higher urinary BKV loads, the peak loads were closely related with the onset of HC. Higher BKV loads may be a risk factor for the development of HC in conjunction with other coexisting factors.
Ontogeny of intestinal safety factors: lactase capacities and lactose loads.
O'Connor, T P; Diamond, J
1999-03-01
We measured intestinal safety factors (ratio of a physiological capacity to the load on it) for lactose digestion in developing rat pups. Specifically, we assessed the quantitative relationships between lactose load and the series capacities of lactase and the Na+-glucose cotransporter (SGLT-1). Both capacities increased significantly with age in suckling pups as a result of increasing intestinal mass and maintenance of mass-specific activities. The youngest pups examined (5 days) had surprisingly high safety factors of 8-13 for both lactase and SGLT-1, possibly because milk contains lactase substrates other than lactose; it also, however, suggests that their intestinal capacities were being prepared to meet future demands rather than just current ones. By day 10 (and also at day 15), increased lactose loads resulted in lower safety factors of 4-6, values more typical of adult intestines. The safety factor of SGLT-1 in day 30 (weanling) and day 100 (adult) rats was only approximately 1.0. This was initially unexpected, because most adult intestines maintain a modest reserve capacity beyond nutrient load values, but postweaning rats appear to use hindgut fermentation, assessed by gut morphology and hydrogen production assays, as a built-in reserve capacity. The series capacities of lactase and SGLT-1 varied in concert with each other over ontogeny and as lactose load was manipulated by experimental variation in litter size.
A factor analytical study of tinnitus complaint behaviour.
Jakes, S C; Hallam, R S; Chambers, C; Hinchcliffe, R
1985-01-01
Two separate factor analyses were conducted on various self-rated complaints about tinnitus and related neuro-otological symptoms, together with audiometric measurements of tinnitus 'intensity' (masking level and loudness matching levels). Two general tinnitus complaint factors were identified, i.e. 'intrusiveness of tinnitus' and 'distress due to tinnitus'. 3 specific tinnitus complaint factors were also found, i.e. 'sleep disturbance', 'medication use' and 'interference with passive auditory entertainments'. Other neuro-otological symptoms and the audiometric measures did not load on these factors. An exception was provided by loudness matches at 1 kHz, which had a small loading on the 'intrusiveness of tinnitus' factor. Self-rated loudness had a high loading on this factor. Otherwise, the loudness (either self-rated or determined by loudness matching) was unrelated to complaint dimensions. The clinical implications of the multifactorial nature of tinnitus complaint behaviour are considered.
A Methodology for Multihazards Load Combinations of Earthquake and Heavy Trucks for Bridges
Wang, Xu; Sun, Baitao
2014-01-01
Issues of load combinations of earthquakes and heavy trucks are important contents in multihazards bridge design. Current load resistance factor design (LRFD) specifications usually treat extreme hazards alone and have no probabilistic basis in extreme load combinations. Earthquake load and heavy truck load are considered as random processes with respective characteristics, and the maximum combined load is not the simple superimposition of their maximum loads. Traditional Ferry Borges-Castaneda model that considers load lasting duration and occurrence probability well describes random process converting to random variables and load combinations, but this model has strict constraint in time interval selection to obtain precise results. Turkstra's rule considers one load reaching its maximum value in bridge's service life combined with another load with its instantaneous value (or mean value), which looks more rational, but the results are generally unconservative. Therefore, a modified model is presented here considering both advantages of Ferry Borges-Castaneda's model and Turkstra's rule. The modified model is based on conditional probability, which can convert random process to random variables relatively easily and consider the nonmaximum factor in load combinations. Earthquake load and heavy truck load combinations are employed to illustrate the model. Finally, the results of a numerical simulation are used to verify the feasibility and rationality of the model. PMID:24883347
Analytical study of pressure balancing in gas film seals
NASA Technical Reports Server (NTRS)
Zuk, J.
1973-01-01
The load factor is investigated for subsonic and choked flow conditions, laminar and turbulent flows, and various seal entrance conditions. Both parallel sealing surfaces and surfaces with small linear deformation were investigated. The load factor for subsonic flow depends strongly on pressure ratio; under choked flow conditions, however the load factor is found to depend more strongly on film thickness and flow entrance conditions rather than pressure ratio. The importance of generating hydrodynamic forces to keep the seal balanced under severe and multipoint operation is also discussed.
NASA Astrophysics Data System (ADS)
Jiang, Yu; Yang, Jiacheng; Gagné, Stéphanie; Chan, Tak W.; Thomson, Kevin; Fofie, Emmanuel; Cary, Robert A.; Rutherford, Dan; Comer, Bryan; Swanson, Jacob; Lin, Yue; Van Rooy, Paul; Asa-Awuku, Akua; Jung, Heejung; Barsanti, Kelley; Karavalakis, Georgios; Cocker, David; Durbin, Thomas D.; Miller, J. Wayne; Johnson, Kent C.
2018-06-01
Knowledge of black carbon (BC) emission factors from ships is important from human health and environmental perspectives. A study of instruments measuring BC and fuels typically used in marine operation was carried out on a small marine engine. Six analytical methods measured the BC emissions in the exhaust of the marine engine operated at two load points (25% and 75%) while burning one of three fuels: a distillate marine (DMA), a low sulfur, residual marine (RMB-30) and a high-sulfur residual marine (RMG-380). The average emission factors with all instruments increased from 0.08 to 1.88 gBC/kg fuel in going from 25 to 75% load. An analysis of variance (ANOVA) tested BC emissions against instrument, load, and combined fuel properties and showed that both engine load and fuels had a statistically significant impact on BC emission factors. While BC emissions were impacted by the fuels used, none of the fuel properties investigated (sulfur content, viscosity, carbon residue and CCAI) was a primary driver for BC emissions. Of the two residual fuels, RMB-30 with the lower sulfur content, lower viscosity and lower residual carbon, had the highest BC emission factors. BC emission factors determined with the different instruments showed a good correlation with the PAS values with correlation coefficients R2 >0.95. A key finding of this research is the relative BC measured values were mostly independent of load and fuel, except for some instruments in certain fuel and load combinations.
NASA Astrophysics Data System (ADS)
Mueller, W. H.; Schmauder, S.
1993-02-01
The plane stress/plane strain problem of radial matrix cracking in fiber-reinforced composites, due to thermal mismatch and externally applied stress is solved numerically in the framework of linear elasticity, using Erdogan's integral equation technique. It is shown that, in order to obtain the results of the combined loading case, the solutions of purely thermal and purely mechanical loading can simply be superimposed. Stress-intensity factors are calculated for various lengths and distances of the crack from the interface for each of these loading conditions.
Human exposure to environmental health concern by types of urban environment: The case of Tel Aviv.
Schnell, Izhak; Potchter, Oded; Yaakov, Yaron; Epstein, Yoram
2016-01-01
This study classifies urban environments into types characterized by different exposure to environmental risk factors measured by general sense of discomfort and Heart Rate Variability (HRV). We hypothesize that a set of environmental factors (micro-climatic, CO, noise and individual heart rate) that were measured simultaneously in random locations can provide a better understanding of the distribution of human exposure to environmental loads throughout the urban space than results calculated based on measurements from close fixed stations. We measured micro-climatic and thermal load, CO and noise, individual Heart Rate, Subjective Social Load and Sense of Discomfort (SD) were tested by questionnaire survey. The results demonstrate significant differences in exposure to environmental factors among 8 types of urban environments. It appears that noise and social load are the more significant environmental factors to enhance health risks and general sense of discomfort. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ameer, Fatima; Munir, Rimsha; Usman, Hina; Rashid, Rida; Shahjahan, Muhammad; Hasnain, Shahida; Zaidi, Nousheen
2017-04-01
Lipid-load in peripheral blood mononuclear cells (PBMCs) has recently gained attention of the researchers working on nutritional regulation of metabolic health. Previous works have indicated that the metabolic circuitries in the circulating PBMCs are influenced by dietary-intake and macronutrient composition of diet. In the present work, we analyzed the impact of diet and dietary macronutrients on PBMCs' lipid-load. The overall analyses revealed that dietary carbohydrates and fats combinatorially induce triglyceride accumulation in PBMCs. On the other hand, dietary fats were shown to induce significant decrease in PBMCs' cholesterol-load. The effects of various demographic factors -including age, gender and body-weight- on PBMCs' lipid-load were also examined. Body-weight and age were both shown to affect PBMC's lipid-load. Our study fails to provide any direct association between extracellular lipid availability and cholesterol-load in both, freshly isolated and cultured PBMCs. The presented work significantly contributes to the current understanding of the impact of food-consumption, dietary macronutrients, extracellular lipid availability and demographic factors on lipid-load in PBMCs. Copyright © 2017 Elsevier B.V. and Société Française de Biochimie et Biologie Moléculaire (SFBBM). All rights reserved.
Three-dimensional finite-element analysis of chevron-notched fracture specimens
NASA Technical Reports Server (NTRS)
Raju, I. S.; Newman, J. C., Jr.
1984-01-01
Stress-intensity factors and load-line displacements were calculated for chevron-notched bar and rod fracture specimens using a three-dimensional finite-element analysis. Both specimens were subjected to simulated wedge loading (either uniform applied displacement or uniform applied load). The chevron-notch sides and crack front were assumed to be straight. Crack-length-to-specimen width ratios (a/w) ranged from 0.4 to 0.7. The width-to-thickness ratio (w/B) was 1.45 or 2. The bar specimens had a height-to-width ratio of 0.435 or 0.5. Finite-element models were composed of singularity elements around the crack front and 8-noded isoparametric elements elsewhere. The models had about 11,000 degrees of freedom. Stress-intensity factors were calculated by using a nodal-force method for distribution along the crack front and by using a compliance method for average values. The stress intensity factors and load-line displacements are presented and compared with experimental solutions from the literature. The stress intensity factors and load-line displacements were about 2.5 and 5 percent lower than the reported experimental values, respectively.
NASA Astrophysics Data System (ADS)
Singaravelu, J.; Sundaresan, S.; Nageswara Rao, B.
2013-04-01
This article presents a methodology for evaluation of the proof load factor (PLF) for clamp band system (CBS) made of M250 Maraging steel following fracture mechanics principles.CBS is most widely used as a structural element and as a separation system. Using Taguchi's design of experiments and the response surface method (RSM) the compact tension specimens were tested to establish an empirical relation for the failure load ( P max) in terms of the ultimate strength, width, thickness, and initial crack length. The test results of P max closely matched with the developed RSM empirical relation. Crack growth rates of the maraging steel in different environments were examined. Fracture strength (σf) of center surface cracks and through-crack tension specimens are evaluated utilizing the fracture toughness ( K IC). Stress induced in merman band at flight loading conditions is evaluated to estimate the higher load factor and PLF. Statistical safety factor and reliability assessments were made for the specified flaw sizes useful in the development of fracture control plan for CBS of launch vehicles.
Surface Irregularity Factor as a Parameter to Evaluate the Fatigue Damage State of CFRP
Zuluaga-Ramírez, Pablo; Frövel, Malte; Belenguer, Tomás; Salazar, Félix
2015-01-01
This work presents an optical non-contact technique to evaluate the fatigue damage state of CFRP structures measuring the irregularity factor of the surface. This factor includes information about surface topology and can be measured easily on field, by techniques such as optical perfilometers. The surface irregularity factor has been correlated with stiffness degradation, which is a well-accepted parameter for the evaluation of the fatigue damage state of composite materials. Constant amplitude fatigue loads (CAL) and realistic variable amplitude loads (VAL), representative of real in- flight conditions, have been applied to “dog bone” shaped tensile specimens. It has been shown that the measurement of the surface irregularity parameters can be applied to evaluate the damage state of a structure, and that it is independent of the type of fatigue load that has caused the damage. As a result, this measurement technique is applicable for a wide range of inspections of composite material structures, from pressurized tanks with constant amplitude loads, to variable amplitude loaded aeronautical structures such as wings and empennages, up to automotive and other industrial applications. PMID:28793655
NASA Technical Reports Server (NTRS)
Boshar, John
1947-01-01
Results are presented of a flight investigation conducted on a fighter-type airplane to determine the factors which affect the loads and load distributions on the vertical tail surfaces in maneuvers. An analysis is made of the data obtained in steady flight, rudder kicks, and fishtail maneuvers. For the rudder kicks, the significant loads were the "deflection load" resulting from an abrupt control deflection and the "dynamic load" consisting of a load corresponding to the new static equilibrium condition for the rudder deflected plus a load due to a transient overshoot. The minimum time to reach the maximum control deflection attainable by the pilot in any flight condition was found to be a constant. In the fishtail maneuvers, it was found that the pilot tends to deflect the rudder in phase with the natural frequency of the airplane. The maximum loads measured in fishtails were of the same order of magnitude as those from a rudder kick in which the rudder is returned to zero at the time of maximum sideslip.
Load and resistance factor design of drilled shafts in shale for lateral loading.
DOT National Transportation Integrated Search
2014-04-01
A research project involving 32 drilled shaft load tests was undertaken to establish LRFD procedures for : design of drilled shafts subjected to lateral loads. Tests were performed at two Missouri Department of : Transportation (MoDOT) geotechnical r...
National Launch System cycle 1 loads and models data book
NASA Technical Reports Server (NTRS)
Bugg, F.; Brunty, J.; Ernsberger, G.; Mcghee, D.; Gagliano, L.; Harrington, F.; Meyer, D.; Blades, E.
1992-01-01
This document contains preliminary cycle 1 loads for the National Launch System (NLS) 1 and 2 vehicles. The loads provided and recommended as design loads represent the maximum load expected during prelaunch and flight regimes, i.e., limit loads, except that propellant tank ullage pressure has not been included. Ullage pressure should be added to the loads book values for cases where the addition results in higher loads. The loads must be multiplied by the appropriate factors of safety to determine the ultimate loads for which the structure must be capable.
14 CFR 23.531 - Hull and main float takeoff condition.
Code of Federal Regulations, 2011 CFR
2011-01-01
... or main float— (a) The aerodynamic wing lift is assumed to be zero; and (b) A downward inertia load...=inertia load factor; CTO=empirical seaplane operations factor equal to 0.004; VS1=seaplane stalling speed...
14 CFR 23.531 - Hull and main float takeoff condition.
Code of Federal Regulations, 2014 CFR
2014-01-01
... or main float— (a) The aerodynamic wing lift is assumed to be zero; and (b) A downward inertia load...=inertia load factor; CTO=empirical seaplane operations factor equal to 0.004; VS1=seaplane stalling speed...
14 CFR 23.531 - Hull and main float takeoff condition.
Code of Federal Regulations, 2013 CFR
2013-01-01
... or main float— (a) The aerodynamic wing lift is assumed to be zero; and (b) A downward inertia load...=inertia load factor; CTO=empirical seaplane operations factor equal to 0.004; VS1=seaplane stalling speed...
14 CFR 23.531 - Hull and main float takeoff condition.
Code of Federal Regulations, 2012 CFR
2012-01-01
... or main float— (a) The aerodynamic wing lift is assumed to be zero; and (b) A downward inertia load...=inertia load factor; CTO=empirical seaplane operations factor equal to 0.004; VS1=seaplane stalling speed...
Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hogue, M. G.; Gause-Lott, S. M.; Owensby, B. N.
Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dustmore » loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2.« less
Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set
Hogue, M. G.; Gause-Lott, S. M.; Owensby, B. N.; ...
2018-03-03
Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dustmore » loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2.« less
NASA Astrophysics Data System (ADS)
Diniş, C. M.; Cunţan, C. D.; Rob, R. O. S.; Popa, G. N.
2018-01-01
The paper presents the analysis of a power factor with capacitors banks, without series coils, used for improving power factor for a three-phase and single-phase inductive loads. In the experimental measurements, to improve the power factor, the Roederstein ESTAmat RPR power factor controller can command up to twelve capacitors banks, while experimenting using only six capacitors banks. Six delta capacitors banks with approximately equal reactive powers were used for experimentation. The experimental measurements were carried out with a three-phase power quality analyser which worked in three cases: a case without a controller with all capacitors banks permanently parallel connected with network, and two other cases with power factor controller (one with setting power factor at 0.92 and the other one at 1). When performing experiments with the power factor controller, a current transformer was used to measure the current on one phase (at a more charged or less loaded phase).
HPV-16 viral load in oropharyngeal squamous cell carcinoma using digital PCR.
Antonsson, Annika; Knight, Lani; Panizza, Benedict J; Porceddu, Sandro V; Emmett, Sarah; Whiteman, David C
2018-05-09
We did not identify any strong associations between HPV-16 viral load and any of the clinical or lifestyle factors. The epidemiology of oropharyngeal SCC is changing, with an increasing proportion of HPV-positive cases seen in the last decade. It is known that a high viral load is linked to the development of cervical cancer, the relation between viral load and oropharyngeal SCC is less clear. We sought to determine HPV-16 viral load in HPV-positive oropharyngeal SCCs using highly sensitive digital PCR and to identify clinical and lifestyle factors associated with viral load. We analysed 45 HPV-16 positive oropharyngeal SCCs diagnosed between 2013 and 2015. All patients completed a lifestyle questionnaire and clinical data were extracted from medical charts. Viral load was determined using digital PCR assays for HPV-L1 and RNAseP. We found large variations in HPV-16 viral load from 1 to 930 copies per cell (median 34 copies per cell).
14 CFR 23.363 - Side load on engine mount.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Side load on engine mount. 23.363 Section....363 Side load on engine mount. (a) Each engine mount and its supporting structure must be designed for a limit load factor in a lateral direction, for the side load on the engine mount, of not less than...
14 CFR 23.363 - Side load on engine mount.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Side load on engine mount. 23.363 Section....363 Side load on engine mount. (a) Each engine mount and its supporting structure must be designed for a limit load factor in a lateral direction, for the side load on the engine mount, of not less than...
14 CFR 23.363 - Side load on engine mount.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Side load on engine mount. 23.363 Section....363 Side load on engine mount. (a) Each engine mount and its supporting structure must be designed for a limit load factor in a lateral direction, for the side load on the engine mount, of not less than...
14 CFR 23.363 - Side load on engine mount.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Side load on engine mount. 23.363 Section....363 Side load on engine mount. (a) Each engine mount and its supporting structure must be designed for a limit load factor in a lateral direction, for the side load on the engine mount, of not less than...
14 CFR 23.363 - Side load on engine mount.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Side load on engine mount. 23.363 Section....363 Side load on engine mount. (a) Each engine mount and its supporting structure must be designed for a limit load factor in a lateral direction, for the side load on the engine mount, of not less than...
Rising breakeven load factors threaten airline finances
DOT National Transportation Integrated Search
2003-10-01
Since 2000, most large passenger airlines suffered a sharp increase in their Breakeven Load Factor the number of seats they have to sell to cover operating expenses. Some carriers could not cover operating expenses even if they sold 100% of their...
Reliability-based evaluation of bridge components for consistent safety margins.
DOT National Transportation Integrated Search
2010-10-01
The Load and Resistant Factor Design (LRFD) approach is based on the concept of structural reliability. The approach is more : rational than the former design approaches such as Load Factor Design or Allowable Stress Design. The LRFD Specification fo...
Parenti, Carmela; Turnaturi, Rita
2017-01-01
Lipid nanocarriers show occlusive properties that may be related to their ability to improve skin hydration. The aim of this work was to evaluate the relationship between in vitro occlusion factor and in vivo skin hydration for three types of lipid nanocarriers: nanoemulsions (NEs), solid lipid nanoparticles (SLNs) and nanostructured lipid carriers (NLCs). These lipid nanocarriers were loaded with trans-resveratrol (RSV) and incorporated in gel vehicles. In vitro occlusion factor was in the order SLNs > NLCs > NEs. Gels containing unloaded or RSV loaded lipid nanocarriers were applied on the back of a hand of 12 healthy volunteers twice a day for one week, recording skin hydration changes using the instrument Soft Plus. An increase of skin hydration was observed for all lipid nanocarriers (SLNs > NLCs > NEs). RSV loading into these nanocarriers did not affect in vitro and in vivo lipid nanocarriers effects. A linear relationship (r2 = 0.969) was observed between occlusion factor and in vivo increase of skin hydration. Therefore, the results of this study showed the feasibility of using the occlusion factor to predict in vivo skin hydration resulting from topical application of different lipid nanocarriers loading an active ingredient with no inherent hydrating activity. PMID:29232856
Molecular mechanisms of the genetic risk factors in pathogenesis of Alzheimer disease.
Kanatsu, Kunihiko; Tomita, Taisuke
2017-01-01
Alzheimer disease (AD) is a neurodegenerative disease characterized by the extensive deposition of senile plaques and neurofibrillary tangles. Until recently, only the APOE gene had been known as a genetic risk factor for late-onset AD (LOAD), which accounts for more than 95% of all AD cases. However, in addition to this well-established genetic risk factor, genome-wide association studies have identified several single nucleotide polymorphisms as genetic risk factors of LOAD, such as PICALM and BIN1 . In addition, whole genome sequencing and exome sequencing have identified rare variants associated with LOAD, including TREM2 . We review the recent findings related to the molecular mechanisms by which these genetic risk factors contribute to AD, and our perspectives regarding the etiology of AD for the development of therapeutic agents.
Lai, Junmin; Lin, Wu; Scholes, Peter; Li, Mingzhong
2017-01-01
The aim of the study was to investigate the effects of the loading factors, i.e., the initial drug loading concentration and the ratio of the drug to carriers, on the in vitro pharmaceutical performance of drug-loaded mesoporous systems. Ibuprofen (IBU) was used as a model drug, and two non-ordered mesoporous materials of commercial silica Syloid® 244FP (S244FP) and Neusilin® US2 (NS2) were selected in the study. The IBU-loaded mesoporous samples were prepared by a solvent immersion method with a rotary evaporation drying technique and characterized by polarized light microscopy (PLM), Fourier transform infrared (FTIR) spectroscopy, X-ray powder diffraction (XRPD) and differential scanning calorimetry (DSC). Dissolution experiments were performed in simulated gastric media at 37 °C under non-sink conditions. The concentration of IBU in solution was determined by HPLC. The study showed that the dissolution rate of IBU can be improved significantly using the mesoporous S224FP carriers due to the conversion of crystalline IBU into the amorphous form. Both of the loading factors affected the IBU dissolution kinetics. Due to the molecular interaction between the IBU and NS2 carriers, the loading factors had little effects on the drug release kinetics with incomplete drug desorption recovery and insignificant dissolution enhancement. Care and extensive evaluation must therefore be taken when mesoporous materials are chosen as carrier delivery systems. PMID:28772509
Van Strien, Tatjana; van Niekerk, Rianne; Ouwens, Machteld A
2009-08-01
To better understand whether the parental food controlling practices pressure and restriction to eat are obesity preventing or obesity promoting, this study examined whether these parenting practices are related to other (food or non-food) areas that are generally regarded as obesogenic or leptogenic. Are these foods controlling practices more indicative of obesogenic or leptogenic child life style behaviors? In a sample of 7-12-year-old boys and girls (n = 943) the perceived parental food controlling practices were related to various measures for unhealthy life style. Using factor analysis we assessed whether there is a constellation of lifestyle behaviors that is potentially obesogenic or leptogenic. Remarkably, perceived parental restriction and pressure loaded on two different factors. Perceived parental restriction to eat had a negative loading on a factor that further comprised potential obesogenic child life style behaviors, such as snacking (positive loading), time spend with screen media (television or computer) (positive loadings) and frequency of fruit consumption (negative loading). Perceived parental pressure to eat had a positive loading on a factor that further comprised potential leptogenic life style behaviors such as frequency of eating a breakfast meal and sporting (positive loadings). It is concluded that low perceived parental restriction in regard to food may perhaps be a sign of more uninvolved 'neglecting' or indulgent parenting/obesogenic home environment, whereas high perceived parental pressure to eat may be sign of a more 'concerned' leptogenic parenting/home environment, though more research into style of parenting is needed.
Effects of partitioning and scheduling sparse matrix factorization on communication and load balance
NASA Technical Reports Server (NTRS)
Venugopal, Sesh; Naik, Vijay K.
1991-01-01
A block based, automatic partitioning and scheduling methodology is presented for sparse matrix factorization on distributed memory systems. Using experimental results, this technique is analyzed for communication and load imbalance overhead. To study the performance effects, these overheads were compared with those obtained from a straightforward 'wrap mapped' column assignment scheme. All experimental results were obtained using test sparse matrices from the Harwell-Boeing data set. The results show that there is a communication and load balance tradeoff. The block based method results in lower communication cost whereas the wrap mapped scheme gives better load balance.
Electrical Load Profile Analysis Using Clustering Techniques
NASA Astrophysics Data System (ADS)
Damayanti, R.; Abdullah, A. G.; Purnama, W.; Nandiyanto, A. B. D.
2017-03-01
Data mining is one of the data processing techniques to collect information from a set of stored data. Every day the consumption of electricity load is recorded by Electrical Company, usually at intervals of 15 or 30 minutes. This paper uses a clustering technique, which is one of data mining techniques to analyse the electrical load profiles during 2014. The three methods of clustering techniques were compared, namely K-Means (KM), Fuzzy C-Means (FCM), and K-Means Harmonics (KHM). The result shows that KHM is the most appropriate method to classify the electrical load profile. The optimum number of clusters is determined using the Davies-Bouldin Index. By grouping the load profile, the demand of variation analysis and estimation of energy loss from the group of load profile with similar pattern can be done. From the group of electric load profile, it can be known cluster load factor and a range of cluster loss factor that can help to find the range of values of coefficients for the estimated loss of energy without performing load flow studies.
NASA Technical Reports Server (NTRS)
Kussner, H G; Thalau, Karl
1933-01-01
Load factors and loading conditions are presented for Germany, England, and the United States. Results of tests are presented and loading conditions are presented under various stress categories like freight, commercial, aerobatics, and training.
Soil and groundwater attenuation factors for nitrogen from septic systems in the Chesapeake Bay TMDL
NASA Astrophysics Data System (ADS)
Radcliffe, D. E.; Geza, M.; O'Drisoll, M.; Humphrey, C., Jr.
2015-12-01
An expert panel was tasked with estimating the percent of the nitrogen (N) load from septic systems that was lost in the flow path from a typical home to third-order streams as part of the Chesapeake Bay Total Maximum Daily Load (TMDL). These losses were referred to as attenuation factors. We developed values for the soil (unsaturated) zone and for the Piedmont and Coastal Plain groundwater zones. For the soil zone, we used the Soil Treatment Unit MODel (STUMOD) to estimate loses due to denitrification for all 12 soil textural classes and then averaged the results over three textural groups. Assuming hydraulic loading at the design rate and a conventional system, the attenuation factors were 16% for sand, loamy sand, sandy loam, and loam soils; 34% for silt loam, clay loam, sandy clay loam, silty clay loam, and silt soils; and 54% for sandy clay, silty clay, and clay soils. Attenuation factors increased in the more clayey soils due to wetter conditions and more losses due to denitrification. Attenuation factors were also developed for reduced hydraulic loading rates and for systems using advanced N pre-treatment. For the Piedmont groundwater zone, we used data from a recent study in Georgia of small suburban streams with high-density septic systems. Stream base-flow load was estimated using simultaneous measurements of total N concentration and discharge and compared to the estimated groundwater input load, resulting in an attenuation factor of 81%. For the Coastal Plain groundwater zone, literature values of groundwater N concentrations within septic system plumes in Virginia, North Carolina, and Florida were used to estimate an attenuation factor of approximately 60% at 100m downgradient from the drainfield. These attenuation factors will be used to estimate the contribution of N to the Chesapeake Bay in the Phase 6 TMDL models.
14 CFR 23.813 - Emergency exit access.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the door is subjected to the inertia loads resulting from the ultimate static load factors prescribed... it by the door when the door is subjected to the inertia loads resulting from the ultimate static...
14 CFR 23.813 - Emergency exit access.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the door is subjected to the inertia loads resulting from the ultimate static load factors prescribed... it by the door when the door is subjected to the inertia loads resulting from the ultimate static...
14 CFR 23.813 - Emergency exit access.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the door is subjected to the inertia loads resulting from the ultimate static load factors prescribed... it by the door when the door is subjected to the inertia loads resulting from the ultimate static...
14 CFR 23.813 - Emergency exit access.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the door is subjected to the inertia loads resulting from the ultimate static load factors prescribed... it by the door when the door is subjected to the inertia loads resulting from the ultimate static...
14 CFR 23.813 - Emergency exit access.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the door is subjected to the inertia loads resulting from the ultimate static load factors prescribed... it by the door when the door is subjected to the inertia loads resulting from the ultimate static...
Load and resistance factor rating (LRFR) in New York State : volume II.
DOT National Transportation Integrated Search
2011-09-01
This report develops a Load and Resistance Factor Rating (NYS-LRFR) methodology : for New York bridges. The methodology is applicable for the rating of existing : bridges, the posting of under-strength bridges, and checking Permit trucks. The : propo...
Load and resistance factor rating (LRFR) in NYS : volume II final report.
DOT National Transportation Integrated Search
2011-09-01
This report develops a Load and Resistance Factor Rating (NYS-LRFR) methodology for New York bridges. The methodology is applicable for the rating of existing bridges, the posting of under-strength bridges, and checking Permit trucks. The proposed LR...
Resistance factors for 100% dynamic testing, with and without static load tests : [summary].
DOT National Transportation Integrated Search
2011-01-01
The Federal Highway Administration (FHWA) and : most state departments of transportation have : adopted the Load and Resistance Factor (LRFD) : approach to design. Critical to the design of : piles in this approach is the development of a : resistanc...
Load and resistance factor rating (LRFR) in NYS : volume I final report.
DOT National Transportation Integrated Search
2011-09-01
This report develops a Load and Resistance Factor Rating (NYS-LRFR) methodology for New York bridges. The methodology is applicable for the rating of existing bridges, the posting of under-strength bridges, and checking Permit trucks. The proposed LR...
Load and resistance factor rating (LRFR) in New York State : volume I.
DOT National Transportation Integrated Search
2011-09-01
This report develops a Load and Resistance Factor Rating (NYS-LRFR) methodology : for New York bridges. The methodology is applicable for the rating of existing : bridges, the posting of under-strength bridges, and checking Permit trucks. The : propo...
Effect of environmental factors on pavement deterioration : Final report, Volume II of II
DOT National Transportation Integrated Search
1988-11-01
A computerized model for the determination of pavement deterioration responsibilities due to load and non-load related factors was developed. The model is based on predicted pavement performance and the relationship of pavement performance to a quant...
Effect of environmental factors on pavement deterioration : Final report, Volume I of II.
DOT National Transportation Integrated Search
1988-11-01
A computerized model for the determination of pavement deterioration responsibilities due to load and non-load related factors was developed. The model is based on predicted pavement performance and the relationship of pavement performance to a quant...
Ranasinha, S; Joham, A E; Norman, R J; Shaw, J E; Zoungas, S; Boyle, J; Moran, L; Teede, H J
2015-12-01
Polycystic ovary syndrome (PCOS) affects 12-21% of women. Women with PCOS exhibit clustering of metabolic features. We applied rigorous statistical methods to further understand the interplay between PCOS and metabolic features including insulin resistance, obesity and androgen status. Retrospective cross-sectional analysis. Women with PCOS attending reproductive endocrine clinics in South Australia for the treatment of PCOS (n = 172). Women without PCOS (controls) in the same Australian region (n = 335) from the Australian Diabetes, Obesity and Lifestyle Study (AusDiab), a national population-based study (age- and BMI-matched within one standard deviation of the PCOS cohort). The factor structure for metabolic syndrome for women with PCOS and control groups was examined, specifically, the contribution of individual factors to metabolic syndrome and the association of hyperandrogenism with other metabolic factors. Women with PCOS demonstrated clustering of metabolic features that was not observed in the control group. Metabolic syndrome in the PCOS cohort was strongly represented by obesity (standardized factor loading = 0·95, P < 0·001) and insulin resistance factors (loading = 0·92, P < 0·001) and moderately by blood pressure (loading = 0·62, P < 0·001) and lipid factors (loading = 0·67, P = 0·002). On further analysis, the insulin resistance factor strongly correlated with the obesity (r = 0·70, P < 0·001) and lipid factors (r = 0·68, P < 0·001) and moderately with the blood pressure factor (loading = 0·43, P = 0·002). The hyperandrogenism factor was moderately correlated with the insulin resistance factor (r = 0·38, P < 0·003), but did not correlate with any other metabolic factors. PCOS women are more likely to display metabolic clustering in comparison with age- and BMI-matched control women. Obesity and insulin resistance, but not androgens, are independently and most strongly associated with metabolic syndrome in PCOS. © 2015 John Wiley & Sons Ltd.
Ryberg, Karen R.; Blomquist, Joel; Sprague, Lori A.; Sekellick, Andrew J.; Keisman, Jennifer
2018-01-01
Causal attribution of changes in water quality often consists of correlation, qualitative reasoning, listing references to the work of others, or speculation. To better support statements of attribution for water-quality trends, structural equation modeling was used to model the causal factors of total phosphorus loads in the Chesapeake Bay watershed. By transforming, scaling, and standardizing variables, grouping similar sites, grouping some causal factors into latent variable models, and using methods that correct for assumption violations, we developed a structural equation model to show how causal factors interact to produce total phosphorus loads. Climate (in the form of annual total precipitation and the Palmer Hydrologic Drought Index) and anthropogenic inputs are the major drivers of total phosphorus load in the Chesapeake Bay watershed. Increasing runoff due to natural climate variability is offsetting purposeful management actions that are otherwise decreasing phosphorus loading; consequently, management actions may need to be reexamined to achieve target reductions in the face of climate variability.
14 CFR 25.363 - Side load on engine and auxiliary power unit mounts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... § 25.363 Side load on engine and auxiliary power unit mounts. (a) Each engine and auxiliary power unit... the side load on the engine and auxiliary power unit mount, at least equal to the maximum load factor... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Side load on engine and auxiliary power...
14 CFR 25.363 - Side load on engine and auxiliary power unit mounts.
Code of Federal Regulations, 2010 CFR
2010-01-01
... § 25.363 Side load on engine and auxiliary power unit mounts. (a) Each engine and auxiliary power unit... the side load on the engine and auxiliary power unit mount, at least equal to the maximum load factor... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Side load on engine and auxiliary power...
14 CFR 25.363 - Side load on engine and auxiliary power unit mounts.
Code of Federal Regulations, 2013 CFR
2013-01-01
... § 25.363 Side load on engine and auxiliary power unit mounts. (a) Each engine and auxiliary power unit... the side load on the engine and auxiliary power unit mount, at least equal to the maximum load factor... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Side load on engine and auxiliary power...
14 CFR 25.363 - Side load on engine and auxiliary power unit mounts.
Code of Federal Regulations, 2014 CFR
2014-01-01
... § 25.363 Side load on engine and auxiliary power unit mounts. (a) Each engine and auxiliary power unit... the side load on the engine and auxiliary power unit mount, at least equal to the maximum load factor... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Side load on engine and auxiliary power...
14 CFR 25.363 - Side load on engine and auxiliary power unit mounts.
Code of Federal Regulations, 2012 CFR
2012-01-01
... § 25.363 Side load on engine and auxiliary power unit mounts. (a) Each engine and auxiliary power unit... the side load on the engine and auxiliary power unit mount, at least equal to the maximum load factor... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Side load on engine and auxiliary power...
Cyclic load magnitude is a risk factor for a cumulative lower back disorder.
Le, Peter; Solomonow, Moshe; Zhou, Bing-He; Lu, Yun; Patel, Vikas
2007-04-01
Epidemiological data suggest that high loads lifted by workers engaged in static and cyclic daily activities may be a risk factor for low back disorder. Our previous research provided physiological and biomechanical validation of the epidemiological data for static load conditions. The objective of this report was to provide physiological and biomechanical experimental validation to the epidemiological data in cyclic (repetitive) load conditions. Three groups of in vivo feline models were subjected to 3 cyclic load levels in a series of 6 periods of 10 minutes of work spaced by 10 minutes of rest followed by 7 hours of rest. Multifidus electromyography (EMG) and lumbar displacement were statistically analyzed after processing. Delayed muscular hyperexcitability was observed only in moderate (40 N) and high (60 N) loads (P<0.0001) but was absent in low (20 N) loads. The magnitude of the delayed hyperexcitability was found to be higher (P<0.0001) in the high (60 N) loads compared with the moderate (40 N) loads. Exposure to moderate and high loads in cyclic (repetitive) work results in an acute neuromuscular disorder indicative of soft tissue inflammation that may become chronic with further exposure.
Effects of cognitive appraisal and mental workload factors on performance in an arithmetic task.
Galy, Edith; Mélan, Claudine
2015-12-01
We showed in a previous study an additive interaction between intrinsic and extraneous cognitive loads and of participants' alertness in an 1-back working memory task. The interaction between intrinsic and extraneous cognitive loads was only observed when participants' alertness was low (i.e. in the morning). As alertness is known to reflect an individual's general functional state, we suggested that the working memory capacity available for germane cognitive load depends on a participant's functional state, in addition to intrinsic and extraneous loads induced by the task and task conditions. The relationships between the different load types and their assessment by specific load measures gave rise to a modified cognitive load model. The aim of the present study was to complete the model by determining to what extent and at what processing level an individual's characteristics intervene in order to implement efficient strategies in a working memory task. Therefore, the study explored participants' cognitive appraisal of the situation in addition to the load factors considered previously-task difficulty, time pressure and alertness. Each participant performed a mental arithmetic task in four different cognitive load conditions (crossover of two task difficulty conditions and of two time pressure conditions), both while their alertness was low (9 a.m.) and high (4 p.m.). Results confirmed an additive effect of task difficulty and time pressure, previously reported in the 1-back memory task, thereby lending further support to the modified cognitive load model. Further, in the high intrinsic and extraneous load condition, performance was reduced on the morning session (i.e. when alertness was low) on one hand, and in those participants' having a threat appraisal of the situation on the other hand. When these factors were included into the analysis, a performance drop occurred in the morning irrespective of cognitive appraisal, and with threat appraisal in the afternoon (i.e. high alertness). Taken together, these findings indicate that mental overload can be the result of a combination of subject-related characteristics, including alertness and cognitive appraisal, in addition to well-documented task-related components (intrinsic and extraneous load). As the factors investigated in the study are known to be critically involved in a number of real job-activities, the findings suggest that solutions designed to reduce incidents and accidents at work should consider the situation from a global perspective, including individual characteristics, task parameters, and work organization, rather than dealing with each factor separately.
Mashin, V A; Mashina, M N
2004-12-01
In the paper, outcomes of the researches devoted to factor analysis of heart rate variability parameters and definition of the most informative parameters for diagnostics of functional states and an evaluation of level of stability to mental loads, are presented. The factor structure of parameters, which unclude integral level of heart rate variability (1), balance between activity of vagus and brain cortical-limbic systems (2), integrated level of cardiovascular system functioning (3), is substantiated. Factor analysis outcomes have been used for construction of functional state classification, for their differential diagnostics, and for development and check of algorithm for evaluation of the stability level in mental loads.
Dyondi, Deepti; Webster, Thomas J; Banerjee, Rinti
2013-01-01
Gellan xanthan gels have been shown to be excellent carriers for growth factors and as matrices for several tissue engineering applications. Gellan xanthan gels along with chitosan nanoparticles of 297 ± 61 nm diameter, basic fibroblast growth factor (bFGF), and bone morphogenetic protein 7 (BMP7) were employed in a dual growth factor delivery system to promote the differentiation of human fetal osteoblasts. An injectable system with ionic and temperature gelation was optimized and characterized. The nanoparticle loaded gels showed significantly improved cell proliferation and differentiation due to the sustained release of growth factors. A differentiation marker study was conducted, analyzed, and compared to understand the effect of single vs dual growth factors and free vs encapsulated growth factors. Dual growth factor loaded gels showed a higher alkaline phosphatase and calcium deposition compared to single growth factor loaded gels. The results suggest that encapsulation and stabilization of growth factors within nanoparticles and gels are promising for bone regeneration. Gellan xanthan gels also showed antibacterial effects against Pseudomonas aeruginosa, Staphylococcus aureus, and Staphylococcus epidermidis, the common pathogens in implant failure.
Bio-implantable passive on-chip RF-MEMS strain sensing resonators for orthopaedic applications
NASA Astrophysics Data System (ADS)
Melik, Rohat; Kosku Perkgoz, Nihan; Unal, Emre; Puttlitz, Christian; Demir, Hilmi Volkan
2008-11-01
One out of ten bone fractures does not heal properly due to improper load distribution and strain profiles during the healing process. To provide implantable tools for the assessment of bone fractures, we have designed novel, bio-implantable, passive, on-chip, RF-MEMS strain sensors that rely on the resonance frequency shift with mechanical deformation. For this purpose, we modeled, fabricated and experimentally characterized two on-chip sensors with high quality factors for in vivo implantation. One of the sensors has an area of ~0.12 mm2 with a quality factor of ~60 and the other has an area of ~0.07 mm2 with a quality factor of ~70. To monitor the mechanical deformation by measuring the change in the resonance frequencies with the applied load, we employed a controllable, point load applying experimental setup designed and constructed for in vitro characterization. In the case of the sensor with the larger area, when we apply a load of 3920 N, we obtain a frequency shift of ~330 MHz and a quality factor of ~76. For the smaller sensor, the frequency shift and the quality factor are increased to 360 MHz and 95, respectively. These data demonstrate that our sensor chips have the capacity to withstand relatively high physiologic loads, and that the concomitant and very large resonant frequency shift with the applied load is achieved while maintaining a high signal quality factor. These experiments demonstrate that these novel sensors have the capacity for producing high sensitivity strain readout, even when the total device area is considerably small. Also, we have demonstrated that our bio-implantable, passive sensors deliver a telemetric, real-time readout of the strain on a chip. Placing two more resonators on the sides of the sensor to serve as transmitter and receiver antennas, we achieved to transfer contactless power and read out loads in the absence of direct wiring to the sensor. With this model, where telemetric measurements become simpler due to the fact that all sensor system is built on the same chip, we obtain a frequency shift of ~190 MHz with an increase in the quality factor from ~38 to ~46 when a load of 3920 N is applied. Therefore, as a first proof of concept, we have demonstrated the feasibility of our on-chip strain sensors for monitoring the mechanical deformation using telemetry-based systems.
Development of preliminary load and resistance factor design of drilled shafts in Iowa.
DOT National Transportation Integrated Search
2014-10-01
The Federal Highway Administration (FHWA) mandated utilizing the Load and Resistance Factor Design (LRFD) approach for all new : bridges initiated in the United States after October 1, 2007. To achieve part of this goal, a database for Drilled SHAft ...
Guidelines for design and rating of gusset-plate connections for steel truss bridges : [tech brief].
DOT National Transportation Integrated Search
2014-08-01
The FHWA guide provides rating guidance : on both load and resistance factor rating : (LRFR) and load factor rating philosophies. : Discussions in this TechBrief are from the LRFR : perspective only. The FHWA guide recommends five resistance checks a...
Random vibration analysis of space flight hardware using NASTRAN
NASA Technical Reports Server (NTRS)
Thampi, S. K.; Vidyasagar, S. N.
1990-01-01
During liftoff and ascent flight phases, the Space Transportation System (STS) and payloads are exposed to the random acoustic environment produced by engine exhaust plumes and aerodynamic disturbances. The analysis of payloads for randomly fluctuating loads is usually carried out using the Miles' relationship. This approximation technique computes an equivalent load factor as a function of the natural frequency of the structure, the power spectral density of the excitation, and the magnification factor at resonance. Due to the assumptions inherent in Miles' equation, random load factors are often over-estimated by this approach. In such cases, the estimates can be refined using alternate techniques such as time domain simulations or frequency domain spectral analysis. Described here is the use of NASTRAN to compute more realistic random load factors through spectral analysis. The procedure is illustrated using Spacelab Life Sciences (SLS-1) payloads and certain unique features of this problem are described. The solutions are compared with Miles' results in order to establish trends at over or under prediction.
NASA Technical Reports Server (NTRS)
Whalley, Matthew S.
1993-01-01
A piloted simulation study was performed by the U.S. Army Aeroflighydynamics Directorate to develop insight into the maneuverability requirements for aggressive helicopter maneuvering tasks such as air-to-air combat. Both a conventional helicopter and a helicopter with auxiliary thrust were examined. The aircraft parameters of interest were the normal and longitudinal load factor envelopes. Of particular interest were the mission performance and handling qualities tradeoffs with the parameters of interest. Two air-to-air acquisition and tracking tasks and a return-to-cover task were performed to assess mission performance. Results indicate that without auxiliary thrust, the ownship normal load factor capability needs to match that of the adversary in order to provide satisfactory handling qualities. Auxiliary thrust provides significant handling qualities advantages and can be substituted to some extent for normal load factor capability. Auxiliary thrust levels as low as 0.2 thrust/weight can provide significant handling qualities advantages.
Factors affecting the stability of reverse shoulder arthroplasty: a biomechanical study.
Clouthier, Allison L; Hetzler, Markus A; Fedorak, Graham; Bryant, J Tim; Deluzio, Kevin J; Bicknell, Ryan T
2013-04-01
Despite the success of reverse shoulder arthroplasty (RSA) in treating patients with painful pseudoparalytic shoulders, instability is a common complication and currently the factors affecting stability are not well understood. The objective of this study was to investigate a number of factors as well as the interactions between factors to determine how they affect the stability of the prosthesis. These factors included: active arm posture (abduction and abduction plane angles), loading direction, glenosphere diameter and eccentricity, and humeral socket constraint. Force required to dislocate the joint, determined using a biomechanical shoulder simulator, was used as a measure of stability. A factorial design experiment was implemented to examine the factors and interactions. Actively increasing the abduction angle by 15° leads to a 30% increase in stability and use of an inferior-offset rather than a centered glenosphere improved stability by 17%. Use of a more constrained humeral socket also increased stability; but the effect was dependent on loading direction, with a 88% improvement for superior loading, 66% for posterior, 36% for anterior, and no change for inferior loading. Abduction plane angle and glenosphere diameter had no effect on stability. Increased glenohumeral abduction and the use of an inferior-offset glenosphere were found to increase the stability of RSA. Additionally, use of a more constrained humeral socket increased stability for anterior, posterior, and superior loading. These identified factor effects have the potential to decrease the risk of dislocation following RSA. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Measuring cognitive load: mixed results from a handover simulation for medical students.
Young, John Q; Irby, David M; Barilla-LaBarca, Maria-Louise; Ten Cate, Olle; O'Sullivan, Patricia S
2016-02-01
The application of cognitive load theory to workplace-based activities such as patient handovers is hindered by the absence of a measure of the different load types. This exploratory study tests a method for measuring cognitive load during handovers. The authors developed the Cognitive Load Inventory for Handoffs (CLI4H) with items for intrinsic, extraneous, and germane load. Medical students completed the measure after participating in a simulated handover. Exploratory factor and correlation analyses were performed to collect evidence for validity. Results yielded a two-factor solution for intrinsic and germane load that explained 50 % of the variance. The extraneous load items performed poorly and were removed from the model. The score for intrinsic load correlated with the Paas Cognitive Load scale (r = 0.31, p = 0.004) and was lower for students with more prior handover training (p = 0.036). Intrinsic load did not, however, correlate with performance. Germane load did not correlate with the Paas Cognitive Load scale but did correlate as expected with performance (r = 0.30, p = 0.005) and was lower for those students with more prior handover training (p = 0.03). The CLI4H yielded mixed results with some evidence for validity of the score from the intrinsic load items. The extraneous load items performed poorly and the use of only a single item for germane load limits conclusions. The instrument requires further development and testing. Study results and limitations provide guidance to future efforts to measure cognitive load during workplace-based activities, such as handovers.
Postma, Dirkje S; Anzueto, Antonio R; Jenkins, Christine; Make, Barry J; Similowski, Thomas; Östlund, Ollie; Eriksson, Göran S; Calverley, Peter M
2013-12-01
The clinical and demographic variables defining the heterogeneity of chronic obstructive pulmonary disease (COPD) are unclear. A post-hoc analysis of five randomised studies in patients with a history of previous exacerbations examined the clinical and demographic characteristics describing moderate-to-very-severe COPD. Factor analysis was performed on all continuous baseline demographic and clinical data, without variable selection. Analyses were based on the full cohort and on stratifications by pack-years smoked, smoking status, gender, and comorbidities; patient exacerbation history was analysed in two of the five studies. 6162 COPD patients were evaluated (70% male; 40% current smokers; mean pre-bronchodilator forced expiratory volume in 1 s [FEV1] 35.2% predicted). Baseline clinical and demographic variables loaded differentially on six factors with minimal overlap, explaining 60.4% of the heterogeneity: 1) symptoms (cough, dyspnoea, sleep disturbance), health status, reliever use; 2) pre-bronchodilator FEV1, FEV1/forced vital capacity, morning peak expiratory flow (PEF), body mass index (BMI); 3) blood pressure; 4) age, months since first COPD symptoms; 5) PEF variability; 6) pulse, FEV1 reversibility. Most factors loaded similarly in stratified and exacerbation analyses. BMI loaded with reversibility in females, and with age and months since first COPD symptoms in ex-smokers. Exacerbations loaded to factor 6. Readily available data can explain ≈ 60% of COPD heterogeneity in a large dataset of predominantly severe COPD patients. Factors were robust over determinants of disease outcome; gender, smoking status, pack-years smoked, and comorbidities. The main factors were largely unchanged by adding exacerbations. Only BMI loaded to other factors. Copyright © 2013. Published by Elsevier Ltd.
Altered sensory-motor control of the head as an etiological factor in space-motion sickness
NASA Technical Reports Server (NTRS)
Lackner, J. R.; DiZio, P.
1989-01-01
Mechanical unloading during head movements in weightlessness may be an etiological factor in space-motion sickness. We simulated altered head loading on Earth without affecting vestibular stimulation by having subjects wear a weighted helmet. Eight subjects were exposed to constant velocity rotation about a vertical axis with direction reversals every 60 sec. for eight reversals with the head loaded and eight with the head unloaded. The severity of motion sickness elicited was significantly higher when the head was loaded. This suggests that altered sensory-motor control of the head is also an etiological factor in space-motion sickness.
Cognitive task load in a naval ship control centre: from identification to prediction.
Grootjen, M; Neerincx, M A; Veltman, J A
Deployment of information and communication technology will lead to further automation of control centre tasks and an increasing amount of information to be processed. A method for establishing adequate levels of cognitive task load for the operators in such complex environments has been developed. It is based on a model distinguishing three load factors: time occupied, task-set switching, and level of information processing. Application of the method resulted in eight scenarios for eight extremes of task load (i.e. low and high values for each load factor). These scenarios were performed by 13 teams in a high-fidelity control centre simulator of the Royal Netherlands Navy. The results show that the method provides good prediction of the task load that will actually appear in the simulator. The model allowed identification of under- and overload situations showing negative effects on operator performance corresponding to controlled experiments in a less realistic task environment. Tools proposed to keep the operator at an optimum task load are (adaptive) task allocation and interface support.
Kamalinia, Mojtaba; Nasl Saraji, Gebreal; Kee, Dohyung; Hosseini, Mostafa; Choobineh, Alireza
2013-01-01
Changes in industries and work practices have coincided with work-related musculoskeletal disorders (MSDs). This study was conducted to determine the prevalence of MSDs and to assess postural loading in assembly workers of an Iranian telecommunication manufacturing company. Data were collected from 193 randomly selected workers in 4 units of the company. The Nordic musculoskeletal disorders questionnaire and the UBC ergonomic checklist were used as data collection tools. Loading on the upper body assessment (LUBA) was used to assess postural loading. Lower back symptoms were the most prevalent problems among the workers (67.9%). LUBA showed that most assembly workers (94.3%) had experienced considerable and high postural loading (postural load index, PLI > 5). Regression analyses revealed that lighting, rotation, contact stress, repetition, gender and age were factors associated with symptoms. Work-related MSDs occurred at a high rate among workers. Postural loading requires consideration. Any ergonomic intervention should focus on eliminating ergonomic factors associated with symptoms.
Review of Rail Behavior Under Wheel/Rail Impact Loading
DOT National Transportation Integrated Search
1986-04-01
The report discusses several studies involving factors that significantly affect rail life, particularly wheel impact loads. Parameters that characterize the effect of wheel impact loads on rail behavior are examined in terms of system variables such...
McCormick, Paul V.; Campbell, Sharon G.
2007-01-01
A literature review of best management practices to reduce nutrient loading was performed to provide information for resource managers in the Klamath Basin, Oregon. Although BMPs have already been implemented in the watershed, some sense of their effectiveness in reducing phosphorus loading and their cost for installation and maintenance is still lacking. This report discusses both causes of nutrient loading and a wide-variety of BMPs used to treat or reduce causal factors. We specifically focused on cattle grazing as the principal land-use and causal factor for nutrient loading in the Klamath Basin above Upper Klamath Lake, Oregon. Several BMP types, including stream corridor fencing, riparian buffer strips and constructed wetlands, seem to have potential for reducing phosphorus loading that may result from cattle grazing. However, no single BMP is likely to be the most effective in all locations or situations.
Poor phonetic perceivers are affected by cognitive load when resolving talker variability
Antoniou, Mark; Wong, Patrick C. M.
2015-01-01
Speech training paradigms aim to maximise learning outcomes by manipulating external factors such as talker variability. However, not all individuals may benefit from such manipulations because subject-external factors interact with subject-internal ones (e.g., aptitude) to determine speech perception and/or learning success. In a previous tone learning study, high-aptitude individuals benefitted from talker variability, whereas low-aptitude individuals were impaired. Because increases in cognitive load have been shown to hinder speech perception in mixed-talker conditions, it has been proposed that resolving talker variability requires cognitive resources. This proposal leads to the hypothesis that low-aptitude individuals do not use their cognitive resources as efficiently as those with high aptitude. Here, high- and low-aptitude subjects identified pitch contours spoken by multiple talkers under high and low cognitive load conditions established by a secondary task. While high-aptitude listeners outperformed low-aptitude listeners across load conditions, only low-aptitude listeners were impaired by increased cognitive load. The findings suggest that low-aptitude listeners either have fewer available cognitive resources or are poorer at allocating attention to the signal. Therefore, cognitive load is an important factor when considering individual differences in speech perception and training paradigms. PMID:26328675
Poor phonetic perceivers are affected by cognitive load when resolving talker variability.
Antoniou, Mark; Wong, Patrick C M
2015-08-01
Speech training paradigms aim to maximise learning outcomes by manipulating external factors such as talker variability. However, not all individuals may benefit from such manipulations because subject-external factors interact with subject-internal ones (e.g., aptitude) to determine speech perception and/or learning success. In a previous tone learning study, high-aptitude individuals benefitted from talker variability, whereas low-aptitude individuals were impaired. Because increases in cognitive load have been shown to hinder speech perception in mixed-talker conditions, it has been proposed that resolving talker variability requires cognitive resources. This proposal leads to the hypothesis that low-aptitude individuals do not use their cognitive resources as efficiently as those with high aptitude. Here, high- and low-aptitude subjects identified pitch contours spoken by multiple talkers under high and low cognitive load conditions established by a secondary task. While high-aptitude listeners outperformed low-aptitude listeners across load conditions, only low-aptitude listeners were impaired by increased cognitive load. The findings suggest that low-aptitude listeners either have fewer available cognitive resources or are poorer at allocating attention to the signal. Therefore, cognitive load is an important factor when considering individual differences in speech perception and training paradigms.
Evaluation of LA DOTD traffic load data for determination of traffic load equivalency factors
DOT National Transportation Integrated Search
2001-07-01
This study updates Louisiana's Equivalency Factor (LEF) tables, which are used as an integral part of the State's highway design and rehabilitation effort. This study was required because the tables have not been updated in over 15 years and are, as ...
14 CFR 23.529 - Hull and main float landing conditions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... landing. For symmetrical step, bow, and stern landings, the limit water reaction load factors are those....25 tan β times the resultant load in the corresponding symmetrical landing condition; and (2) The... at one float times the step landing load reached under § 23.527. The side load is directed inboard...
14 CFR 23.529 - Hull and main float landing conditions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... landing. For symmetrical step, bow, and stern landings, the limit water reaction load factors are those....25 tan β times the resultant load in the corresponding symmetrical landing condition; and (2) The... at one float times the step landing load reached under § 23.527. The side load is directed inboard...
14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.
Code of Federal Regulations, 2014 CFR
2014-01-01
... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...
14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.
Code of Federal Regulations, 2011 CFR
2011-01-01
... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...
14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.
Code of Federal Regulations, 2010 CFR
2010-01-01
... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...
14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.
Code of Federal Regulations, 2012 CFR
2012-01-01
... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...
14 CFR 23.785 - Seats, berths, litters, safety belts, and shoulder harnesses.
Code of Federal Regulations, 2013 CFR
2013-01-01
... combination of structural analysis and static load tests to limit load; or (3) Static load tests to ultimate... OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY... resulting from the ultimate static load factors prescribed in § 23.561(b)(2) of this part. Each occupant...
Vibration Testing of Electrical Cables to Quantify Loads at Tie-Down Locations
NASA Technical Reports Server (NTRS)
Dutson, Joseph D.
2013-01-01
The standard method for defining static equivalent structural load factors for components is based on Mile s equation. Unless test data is available, 5% critical damping is assumed for all components when calculating loads. Application of this method to electrical cable tie-down hardware often results in high loads, which often exceed the capability of typical tie-down options such as cable ties and P-clamps. Random vibration testing of electrical cables was used to better understand the factors that influence component loads: natural frequency, damping, and mass participation. An initial round of vibration testing successfully identified variables of interest, checked out the test fixture and instrumentation, and provided justification for removing some conservatism in the standard method. Additional testing is planned that will include a larger range of cable sizes for the most significant contributors to load as variables to further refine loads at cable tie-down points. Completed testing has provided justification to reduce loads at cable tie-downs by 45% with additional refinement based on measured cable natural frequencies.
McGivney, C L; Gough, K F; McGivney, B A; Farries, G; Hill, E W; Katz, L M
2018-06-23
Conflicting results have been reported for risk factors for recurrent laryngeal neuropathy (RLN) based on resting endoscopic evaluation and comparison of single conformation traits, with many traits correlated to one another. To simplify identification of signalment and conformation traits (i.e. variables) associated with RLN cases and controls diagnosed with exercising overground endoscopy (OGE) using exploratory factor analysis (EFA). Prospective cohort. Pearson's rank correlation was used to establish significance and association between variables collected from n = 188 Thoroughbreds from one stable by observers blinded to OGE results. Exploratory factor analysis was conducted on 9 variables for cases and controls; common elements between variables developed a factor, with variables grouped into 3 factors for cases and controls, respectively. Correlation (loading) between each variable and factor was calculated to rank relationships between variables and cases/controls, with factors retrospectively named based on their underlying correlations with variables. Numerous inter-correlations were present between variables. Most strongly correlated in cases were wither height with body weight (r = 0.70) and ventral neck length (r = 0.68) and in controls body weight with rostral neck circumference (r = 0.58). Wither height (r = 0.61) significantly loaded the top-ranked factor for cases ('height RLN '), explaining 25% of conformational variance. Ventral neck length (r = 0.69) and age (r = 0.57) significantly loaded the second-ranked factor for cases ('neck length RLN '), explaining 16% of conformational variance. Rostral neck circumference (r = 0.86) and body weight (r = 0.6) significantly loaded the top-ranked factor for controls ('body size CON '), explaining 19% of the variance. Wither height (r = 0.84) significantly loaded the second-ranked factor for controls ('height CON '), explaining 13% of the variance. Horses had not reached skeletal maturity. Exploratory factor analysis allowed weightings to be determined for each variable. Wither height was the predominant conformational feature associated with RLN. Exploratory factor analysis confirms aggregated conformational differences exist between RLN cases and controls, suitable for future evaluations. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
An extravehicular suit impact load attenuation study to improve astronaut bone fracture prediction.
Sulkowski, Christina M; Gilkey, Kelly M; Lewandowski, Beth E; Samorezov, Sergey; Myers, Jerry G
2011-04-01
Understanding the contributions to the risk of bone fracture during spaceflight is essential for mission success. A pressurized extravehicular activity (EVA) suit analogue test bed was developed, impact load attenuation data were obtained, and the load at the hip of an astronaut who falls to the side during an EVA was characterized. Offset (representing the gap between the EVA suit and the astronaut's body), impact load magnitude, and EVA suit operating pressure were factors varied in the study. The attenuation data were incorporated into a probabilistic model of bone fracture risk during spaceflight, replacing the previous load attenuation value that was based on commercial hip protector data. Load attenuation was more dependent on offset than on pressurization or load magnitude, especially at small offset values. Load attenuation factors for offsets between 0.1-1.5 cm were 0.69 +/- 0.15, 0.49 +/- 0.22, and 0.35 +/- 0.18 for mean impact forces of 4827, 6400, and 8467 N, respectively. Load attenuation factors for offsets of 2.8-5.3 cm were 0.93 +/- 0.2, 0.94 +/- 0.1, and 0.84 +/- 0.5 for the same mean impact forces. The mean and 95th percentile bone fracture risk index predictions were each reduced by 65-83%. The mean and 95th percentile bone fracture probability predictions were both reduced approximately 20-50%. The reduction in uncertainty and improved confidence in bone fracture predictions increased the fidelity and credibility of the fracture risk model and its benefit to mission design and in-flight operational decisions.
Simplified Design Method for Tension Fasteners
NASA Astrophysics Data System (ADS)
Olmstead, Jim; Barker, Paul; Vandersluis, Jonathan
2012-07-01
Tension fastened joints design has traditionally been an iterative tradeoff between separation and strength requirements. This paper presents equations for the maximum external load that a fastened joint can support and the optimal preload to achieve this load. The equations, based on linear joint theory, account for separation and strength safety factors and variations in joint geometry, materials, preload, load-plane factor and thermal loading. The strength-normalized versions of the equations are applicable to any fastener and can be plotted to create a "Fastener Design Space", FDS. Any combination of preload and tension that falls within the FDS represents a safe joint design. The equation for the FDS apex represents the optimal preload and load capacity of a set of joints. The method can be used for preliminary design or to evaluate multiple pre-existing joints.
The effects of dynamic loading on the intervertebral disc.
Chan, Samantha C W; Ferguson, Stephen J; Gantenbein-Ritter, Benjamin
2011-11-01
Loading is important to maintain the balance of matrix turnover in the intervertebral disc (IVD). Daily cyclic diurnal assists in the transport of large soluble factors across the IVD and its surrounding circulation and applies direct and indirect stimulus to disc cells. Acute mechanical injury and accumulated overloading, however, could induce disc degeneration. Recently, there is more information available on how cyclic loading, especially axial compression and hydrostatic pressure, affects IVD cell biology. This review summarises recent studies on the response of the IVD and stem cells to applied cyclic compression and hydrostatic pressure. These studies investigate the possible role of loading in the initiation and progression of disc degeneration as well as quantifying a physiological loading condition for the study of disc degeneration biological therapy. Subsequently, a possible physiological/beneficial loading range is proposed. This physiological/beneficial loading could provide insight into how to design loading regimes in specific system for the testing of various biological therapies such as cell therapy, chemical therapy or tissue engineering constructs to achieve a better final outcome. In addition, the parameter space of 'physiological' loading may also be an important factor for the differentiation of stem cells towards most ideally 'discogenic' cells for tissue engineering purpose.
NASA Technical Reports Server (NTRS)
Poe, C. C., Jr.
1973-01-01
A linear elastic stress analysis was made of a centrally cracked sheet stiffened by riveted, uniformly spaced and sized stringers. The stress intensity factor for the sheet and the load concentration factor for the most highly loaded stringer were determined for various numbers of broken stringers. A broken stringer causes the stress intensity factor to be very high when the crack tip is near the broken stringer, but causes little effect when the crack tip extends beyond several intact stringers. A broken stringer also causes an increase in the load concentration factor of the adjacent stringers. The calculated residual strengths and fatigue-crack-growth lives of a stiffened aluminum sheet with a broken stringer were only slightly less than a sheet with all intact stringers, and were still much higher than those of an unstiffened sheet.
Roivainen, Eka
2015-12-01
Vocabularies of natural languages evolve over time. Useful words become more popular and useless concepts disappear. In this study, the frequency of the use of 295 English, 100 German, and 114 French personality adjectives in book texts and Twitter messages as qualifiers of the words person, woman, homme, femme, and Person was studied. Word frequency data were compared to factor loadings from previous factor analytic studies on personality terms. The correlation between the popularity of an adjective and its highest primary loading in five- and six-factor models was low (-0.12 to 0.17). The Big five (six) marker adjectives were not more popular than "blended" adjectives that had moderate loadings on several factors. This finding implies that laymen consider "blended" adjectives as equally useful descriptors compared to adjectives that represent core features of the five (six) factors. These results are compatible with three hypotheses: 1) laymen are not good at describing personality, 2) the five (six) factors are artifacts of research methods, 3) the interaction of the five (six) factors is not well understood.
Comprehensive manual handling limits for lowering, pushing, pulling and carrying activities.
Shoaf, C; Genaidy, A; Karwowski, W; Waters, T; Christensen, D
1997-11-01
The objective of this study was to develop a set of mathematical models for manual lowering, pushing, pulling and carrying activities that would result in establishing load capacity limits to protect the lower back against occupational low-back disorders. In order to establish safe guidelines, a three-stage process was used. First, psychophysical data was used to generate the models' discounting factors and recommended load capacities. Second, biomechanical analysis was used to refine the recommended load capacities. Third, physiological criteria were used to validate the models' discounting factors. Both task and personal factors were considered in the models' development. When compared to the results from prior psychophysical research for these activities, the developed load capacity values are lower than previously established limits. The results of this study allowed the authors to validate the hypothesis proposed and tested by Karwowski (1983) that states that the combination of physiological and biomechanical stresses should lead to the overall measure of task acceptability or the psychophysical stress. This study also found that some of the discounting factors for the task frequency parameters recommended in the prior psychophysical research should not be used as several of the high frequency factors violated physiological limits.
Farm factors associated with reducing Cryptosporidium loading in storm runoff from dairies.
Miller, W A; Lewis, D J; Pereira, M D G; Lennox, M; Conrad, P A; Tate, K W; Atwill, E R
2008-01-01
A systems approach was used to evaluate environmental loading of Cryptosporidium oocysts on five coastal dairies in California. One aspect of the study was to determine Cryptosporidium oocyst concentrations and loads for 350 storm runoff samples from dairy high use areas collected over two storm seasons. Selected farm factors and beneficial management practices (BMPs) associated with reducing the Cryptosporidium load in storm runoff were assessed. Using immunomagnetic separation (IMS) with direct fluorescent antibody (DFA) analysis, Cryptosporidium oocysts were detected on four of the five farms and in 21% of storm runoff samples overall. Oocysts were detected in 59% of runoff samples collected near cattle less than 2 mo old, while 10% of runoff samples collected near cattle over 6 mo old were positive. Factors associated with environmental loading of Cryptosporidium oocysts included cattle age class, 24 h precipitation, and cumulative seasonal precipitation, but not percent slope, lot acreage, cattle stocking number, or cattle density. Vegetated buffer strips and straw mulch application significantly reduced the protozoal concentrations and loads in storm runoff, while cattle exclusion and removal of manure did not. The study findings suggest that BMPs such as vegetated buffer strips and straw mulch application, especially when placed near calf areas, will reduce environmental loading of fecal protozoa and improve stormwater quality. These findings are assisting working dairies in their efforts to improve farm and ecosystem health along the California coast.
Exploratory Study of Factors Influencing Job-Related Stress in Japanese Psychiatric Nurses
Yada, Hironori; Lu, Xi; Omori, Hisamitsu; Abe, Hiroshi; Matsuo, Hisae; Ishida, Yasushi; Katoh, Takahiko
2015-01-01
This study explored the factor structure of psychiatric nurses' job-related stress and examined the specificity of the related stressors using the job stressor scale of the Brief Job Stress Questionnaire (BJSQ). The stressor scale of the BJSQ was administered to 296 nurses and assistant nurses. Answers were examined statistically. Exploratory factor analysis was performed to identify factor structures; two factors (overload and job environment) were valid. Confirmatory factor analysis was conducted to examine the two-factor structure and found 11 items with factor loadings of >0.40 (model 1), 13 items with factor loadings from 0.30 to <0.40 (model 2), and 17 items with factor loadings from 0.20 to <0.30 (model 3) for one factor; model 1 demonstrated the highest goodness of fit. Then, we observed that the two-factor structure (model 1) showed a higher goodness of fit than the original six-factor structure. This differed from subscales based on general workers' job-related stressors, suggesting that the factor structure of psychiatric nurses' job-related stressors is specific. Further steps may be necessary to reduce job-related stress specifically related to overload including attention to many needs of patients and job environment including complex ethical dilemmas in psychiatric nursing. PMID:25922763
Exploratory study of factors influencing job-related stress in Japanese psychiatric nurses.
Yada, Hironori; Lu, Xi; Omori, Hisamitsu; Abe, Hiroshi; Matsuo, Hisae; Ishida, Yasushi; Katoh, Takahiko
2015-01-01
This study explored the factor structure of psychiatric nurses' job-related stress and examined the specificity of the related stressors using the job stressor scale of the Brief Job Stress Questionnaire (BJSQ). The stressor scale of the BJSQ was administered to 296 nurses and assistant nurses. Answers were examined statistically. Exploratory factor analysis was performed to identify factor structures; two factors (overload and job environment) were valid. Confirmatory factor analysis was conducted to examine the two-factor structure and found 11 items with factor loadings of >0.40 (model 1), 13 items with factor loadings from 0.30 to <0.40 (model 2), and 17 items with factor loadings from 0.20 to <0.30 (model 3) for one factor; model 1 demonstrated the highest goodness of fit. Then, we observed that the two-factor structure (model 1) showed a higher goodness of fit than the original six-factor structure. This differed from subscales based on general workers' job-related stressors, suggesting that the factor structure of psychiatric nurses' job-related stressors is specific. Further steps may be necessary to reduce job-related stress specifically related to overload including attention to many needs of patients and job environment including complex ethical dilemmas in psychiatric nursing.
Improved load rating of reinforced concrete slab bridges.
DOT National Transportation Integrated Search
2007-09-01
In New Mexico, many reinforced concrete slab (RCS) bridges provide service on interstates I-10, I-25, and I-40. An accurate strength evaluation of interstate bridges is essential to avoid unnecessary load restrictions. The AASHTO load rating factor f...
Processing Capacity under Perceptual and Cognitive Load: A Closer Look at Load Theory
ERIC Educational Resources Information Center
Fitousi, Daniel; Wenger, Michael J.
2011-01-01
Variations in perceptual and cognitive demands (load) play a major role in determining the efficiency of selective attention. According to load theory (Lavie, Hirst, Fockert, & Viding, 2004) these factors (a) improve or hamper selectivity by altering the way resources (e.g., processing capacity) are allocated, and (b) tap resources rather than…
Decreasing Cognitive Load for Learners: Strategy of Web-Based Foreign Language Learning
ERIC Educational Resources Information Center
Zhang, Jianfeng
2013-01-01
Cognitive load is one of the important factors that influence the effectiveness and efficiency of web-based foreign language learning. Cognitive load theory assumes that human's cognitive capacity in working memory is limited and if it overloads, learning will be hampered, so that high level of cognitive load can affect the performance of learning…
The lag time between groundwater recharge and discharge in a watershed and the potential groundwater load to streams is an important factor in forecasting responses to future land use practices. We call this concept managing the “space-time-load continuum”. It’s understood that i...
DOT National Transportation Integrated Search
2014-01-01
The Advanced Structures and Composites Center at the University of Maine (UMaine) performed live load testing : and rating factor analysis for two bridges (No. 5506 and No. 5507) in Batchelders Grant, Maine. The bridge load : rating performed by cons...
Jayaratne, E R; Ristovski, Z D; Meyer, N; Morawska, L
2009-04-01
Exhaust emissions from thirteen compressed natural gas (CNG) and nine ultralow sulphur diesel in-service transport buses were monitored on a chassis dynamometer. Measurements were carried out at idle and at three steady engine loads of 25%, 50% and 100% of maximum power at a fixed speed of 60 km h(-1). Emission factors were estimated for particle mass and number, carbon dioxide and oxides of nitrogen for two types of CNG buses (Scania and MAN, compatible with Euro 2 and 3 emission standards, respectively) and two types of diesel buses (Volvo Pre-Euro/Euro1 and Mercedez OC500 Euro3). All emission factors increased with load. The median particle mass emission factor for the CNG buses was less than 1% of that from the diesel buses at all loads. However, the particle number emission factors did not show a statistically significant difference between buses operating on the two types of fuel. In this paper, for the very first time, particle number emission factors are presented at four steady state engine loads for CNG buses. Median values ranged from the order of 10(12) particles min(-)(1) at idle to 10(15) particles km(-)(1) at full power. Most of the particles observed in the CNG emissions were in the nanoparticle size range and likely to be composed of volatile organic compounds The CO2 emission factors were about 20% to 30% greater for the diesel buses over the CNG buses, while the oxides of nitrogen emission factors did not show any difference due to the large variation between buses.
Gentis, Nicolaos D; Betz, Gabriele
2012-02-01
The purpose of this work was to investigate and evaluate the powder compressibility of binary mixtures containing a well-compressible compound (microcrystalline cellulose) and a brittle active drug (paracetamol and mefenamic acid) and its progression after a drug load increase. Drug concentration range was 0%-100% (m/m) with 10% intervals. The powder formulations were compacted to several relative densities with the Zwick material tester. The compaction force and tensile strength were fitted to several mathematical models that give representative factors for the powder compressibility. The factors k and C (Heckel and modified Heckel equation) showed mostly a nonlinear correlation with increasing drug load. The biggest drop in both factors occurred at far regions and drug load ranges. This outcome is crucial because in binary mixtures the drug load regions with higher changeover of plotted factors could be a hint for an existing percolation threshold. The susceptibility value (Leuenberger equation) showed varying values for each formulation without the expected trend of decrease for higher drug loads. The outcomes of this study showed the main challenges for good formulation design. Thus, we conclude that such mathematical plots are mandatory for a scientific evaluation and prediction of the powder compaction process. Copyright © 2011 Wiley Periodicals, Inc.
de Sa, Suzane S.; Palm, Brett B.; Campuzano-Jost, Pedro; ...
2017-06-06
The atmospheric chemistry of isoprene contributes to the production of a substantial mass fraction of the particulate matter (PM) over tropical forests. Isoprene epoxydiols (IEPOX) produced in the gas phase by the oxidation of isoprene under HO 2-dominant conditions are subsequently taken up by particles, thereby leading to production of secondary organic PM. The present study investigates possible perturbations to this pathway by urban pollution. The measurement site in central Amazonia was located 4 to 6 hours downwind of Manaus, Brazil. Measurements took place from February through March 2014 of the wet season, as part of the GoAmazon2014/5 experiment. Massmore » spectra of organic PM collected with an Aerodyne Aerosol Mass Spectrometer were analyzed by positive-matrix factorization. One resolved statistical factor (“IEPOX-SOA factor”) was associated with PM production by the IEPOX pathway. Loadings of this factor correlated with independently measured mass concentrations of tracers of IEPOX-derived PM, namely C 5-alkene triols and 2-methyltetrols (R = 0.96 and 0.78, respectively). Factor loading, as well as the ratio of the factor loading to organic PM mass concentration, decreased under polluted compared to background conditions. For the study period, sulfate concentration explained 37 % of the variability in the factor loading. After segregation of the data set by NO y concentration, the sulfate concentration explained up to 75 % of the variability in factor loading within the NO y subsets. The sulfate-detrended IEPOX-SOA factor loading decreased by two- to three-fold for an increase in NO y concentration from 0.5 to 2 ppb. Here, the suppressing effects of elevated NO dominated over the enhancing effects of higher sulfate with respect to the production of IEPOX-derived PM. Relative to background conditions, the Manaus pollution contributed more significantly to NO y than to sulfate. In this light, increased emissions of nitrogen oxides, as anticipated for some scenarios of Amazonian economic development, could significantly alter pathways of PM production that presently prevail over the tropical forest, implying changes to air quality and regional climate.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
de Sa, Suzane S.; Palm, Brett B.; Campuzano-Jost, Pedro
The atmospheric chemistry of isoprene contributes to the production of a substantial mass fraction of the particulate matter (PM) over tropical forests. Isoprene epoxydiols (IEPOX) produced in the gas phase by the oxidation of isoprene under HO 2-dominant conditions are subsequently taken up by particles, thereby leading to production of secondary organic PM. The present study investigates possible perturbations to this pathway by urban pollution. The measurement site in central Amazonia was located 4 to 6 hours downwind of Manaus, Brazil. Measurements took place from February through March 2014 of the wet season, as part of the GoAmazon2014/5 experiment. Massmore » spectra of organic PM collected with an Aerodyne Aerosol Mass Spectrometer were analyzed by positive-matrix factorization. One resolved statistical factor (“IEPOX-SOA factor”) was associated with PM production by the IEPOX pathway. Loadings of this factor correlated with independently measured mass concentrations of tracers of IEPOX-derived PM, namely C 5-alkene triols and 2-methyltetrols (R = 0.96 and 0.78, respectively). Factor loading, as well as the ratio of the factor loading to organic PM mass concentration, decreased under polluted compared to background conditions. For the study period, sulfate concentration explained 37 % of the variability in the factor loading. After segregation of the data set by NO y concentration, the sulfate concentration explained up to 75 % of the variability in factor loading within the NO y subsets. The sulfate-detrended IEPOX-SOA factor loading decreased by two- to three-fold for an increase in NO y concentration from 0.5 to 2 ppb. Here, the suppressing effects of elevated NO dominated over the enhancing effects of higher sulfate with respect to the production of IEPOX-derived PM. Relative to background conditions, the Manaus pollution contributed more significantly to NO y than to sulfate. In this light, increased emissions of nitrogen oxides, as anticipated for some scenarios of Amazonian economic development, could significantly alter pathways of PM production that presently prevail over the tropical forest, implying changes to air quality and regional climate.« less
Swineford, Lauren B; Guthrie, Whitney; Thurm, Audrey
2015-12-01
The purpose of this study was to report on the construct, convergent, and divergent validity of the Mullen Scales of Early Learning (MSEL), a widely used test of development for young children. The sample consisted of 399 children with a mean age of 3.38 years (SD = 1.14) divided into a group of children with autism spectrum disorder (ASD) and a group of children not on the autism spectrum, with and without developmental delays. The study used the MSEL and several other measures assessing constructs relevant to the age range--including developmental skills, autism symptoms, and psychopathology symptoms--across multiple methods of assessment. Multiple-group confirmatory factor analyses revealed good overall fit and equal form of the MSEL 1-factor model across the ASD and nonspectrum groups, supporting the construct validity of the MSEL. However, neither full nor partial invariance of factor loadings was established because of the lower loadings in the ASD group compared with the nonspectrum group. Exploratory structural equation modeling revealed that other measures of developmental skills loaded together with the MSEL domain scores on a Developmental Functioning factor, supporting convergent validity of the MSEL. Divergent validity was supported by the lack of loading of MSEL domain scores on Autism Symptoms or Emotion/Behavior Problems factors. Although factor structure and loadings varied across groups, convergent and divergent validity findings were similar in the ASD and nonspectrum samples. Together, these results demonstrate evidence for the construct, convergent, and divergent validity of the MSEL using powerful data-analytic techniques. (c) 2015 APA, all rights reserved).
RF-MEMS Load Sensors with Enhanced Q-factor and Sensitivity in a Suspended Architecture.
Melik, Rohat; Unal, Emre; Perkgoz, Nihan Kosku; Puttlitz, Christian; Demir, Hilmi Volkan
2011-03-01
In this paper, we present and demonstrate RF-MEMS load sensors designed and fabricated in a suspended architecture that increases their quality-factor (Q-factor), accompanied with an increased resonance frequency shift under load. The suspended architecture is obtained by removing silicon under the sensor. We compare two sensors that consist of 195 μm × 195 μm resonators, where all of the resonator features are of equal dimensions, but one's substrate is partially removed (suspended architecture) and the other's is not (planar architecture). The single suspended device has a resonance of 15.18 GHz with 102.06 Q-factor whereas the single planar device has the resonance at 15.01 GHz and an associated Q-factor of 93.81. For the single planar device, we measured a resonance frequency shift of 430 MHz with 3920 N of applied load, while we achieved a 780 MHz frequency shift in the single suspended device. In the planar triplet configuration (with three devices placed side by side on the same chip, with the two outmost ones serving as the receiver and the transmitter), we observed a 220 MHz frequency shift with 3920 N of applied load while we obtained a 340 MHz frequency shift in the suspended triplet device with 3920 N load applied. Thus, the single planar device exhibited a sensitivity level of 0.1097 MHz/N while the single suspended device led to an improved sensitivity of 0.1990 MHz/N. Similarly, with the planar triplet device having a sensitivity of 0.0561 MHz/N, the suspended triplet device yielded an enhanced sensitivity of 0.0867 MHz/N.
Optical components damage parameters database system
NASA Astrophysics Data System (ADS)
Tao, Yizheng; Li, Xinglan; Jin, Yuquan; Xie, Dongmei; Tang, Dingyong
2012-10-01
Optical component is the key to large-scale laser device developed by one of its load capacity is directly related to the device output capacity indicators, load capacity depends on many factors. Through the optical components will damage parameters database load capacity factors of various digital, information technology, for the load capacity of optical components to provide a scientific basis for data support; use of business processes and model-driven approach, the establishment of component damage parameter information model and database systems, system application results that meet the injury test optical components business processes and data management requirements of damage parameters, component parameters of flexible, configurable system is simple, easy to use, improve the efficiency of the optical component damage test.
Performance simulation of a plasma magnetohydrodynamic power generator
NASA Astrophysics Data System (ADS)
Huang, Hulin; Li, Linyong; Zhu, Guiping
2018-05-01
The performance of magnetohydrodynamic (MHD) power generator is affected by many issues, among which the load coefficient k is of great importance. This paper reveals the relationship between the k and the performance of MHD generator by numerical simulation on Faraday-type MHD power generator using He/Xe as working plasma. The results demonstrate that the power generation efficiency increases with an increment of the load factor. However, the enthalpy extraction firstly increases then decreases with the load factor increasing. The enthalpy extraction rate reaches the maximum when the load coefficient k equals to 0.625, which infers the best performance of the power generator channel with the maximum electricity production.
ADAPTION OF NONSTANDARD PIPING COMPONENTS INTO PRESENT DAY SEISMIC CODES
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. T. Clark; M. J. Russell; R. E. Spears
2009-07-01
With spiraling energy demand and flat energy supply, there is a need to extend the life of older nuclear reactors. This sometimes requires that existing systems be evaluated to present day seismic codes. Older reactors built in the 1960s and early 1970s often used fabricated piping components that were code compliant during their initial construction time period, but are outside the standard parameters of present-day piping codes. There are several approaches available to the analyst in evaluating these non-standard components to modern codes. The simplest approach is to use the flexibility factors and stress indices for similar standard components withmore » the assumption that the non-standard component’s flexibility factors and stress indices will be very similar. This approach can require significant engineering judgment. A more rational approach available in Section III of the ASME Boiler and Pressure Vessel Code, which is the subject of this paper, involves calculation of flexibility factors using finite element analysis of the non-standard component. Such analysis allows modeling of geometric and material nonlinearities. Flexibility factors based on these analyses are sensitive to the load magnitudes used in their calculation, load magnitudes that need to be consistent with those produced by the linear system analyses where the flexibility factors are applied. This can lead to iteration, since the magnitude of the loads produced by the linear system analysis depend on the magnitude of the flexibility factors. After the loading applied to the nonstandard component finite element model has been matched to loads produced by the associated linear system model, the component finite element model can then be used to evaluate the performance of the component under the loads with the nonlinear analysis provisions of the Code, should the load levels lead to calculated stresses in excess of Allowable stresses. This paper details the application of component-level finite element modeling to account for geometric and material nonlinear component behavior in a linear elastic piping system model. Note that this technique can be applied to the analysis of B31 piping systems.« less
Wind Tunnel Strain-Gage Balance Calibration Data Analysis Using a Weighted Least Squares Approach
NASA Technical Reports Server (NTRS)
Ulbrich, N.; Volden, T.
2017-01-01
A new approach is presented that uses a weighted least squares fit to analyze wind tunnel strain-gage balance calibration data. The weighted least squares fit is specifically designed to increase the influence of single-component loadings during the regression analysis. The weighted least squares fit also reduces the impact of calibration load schedule asymmetries on the predicted primary sensitivities of the balance gages. A weighting factor between zero and one is assigned to each calibration data point that depends on a simple count of its intentionally loaded load components or gages. The greater the number of a data point's intentionally loaded load components or gages is, the smaller its weighting factor becomes. The proposed approach is applicable to both the Iterative and Non-Iterative Methods that are used for the analysis of strain-gage balance calibration data in the aerospace testing community. The Iterative Method uses a reasonable estimate of the tare corrected load set as input for the determination of the weighting factors. The Non-Iterative Method, on the other hand, uses gage output differences relative to the natural zeros as input for the determination of the weighting factors. Machine calibration data of a six-component force balance is used to illustrate benefits of the proposed weighted least squares fit. In addition, a detailed derivation of the PRESS residuals associated with a weighted least squares fit is given in the appendices of the paper as this information could not be found in the literature. These PRESS residuals may be needed to evaluate the predictive capabilities of the final regression models that result from a weighted least squares fit of the balance calibration data.
On the Stability of Rotated Factor Loadings: The Wexler Phenomenon.
ERIC Educational Resources Information Center
Jennerich, Robert I.
The formulas which give the standard errors of factor loading estimates while available and computable are complicated, and our understanding of them is limited. A nontechnical description of their behavior under favorable and unfavorable conditions is given. Of particular interest is their behavior in the presence of singularities arising from…
1989-08-01
thermal pulse loadings. The work couples a Green’s function integration technique for transient thermal stresses with the well-known influence ... function approach for calculating stress intensity factors. A total of seven most commonly used crack models were investigated in this study. A computer
Towards a Probabilistic Preliminary Design Criterion for Buckling Critical Composite Shells
NASA Technical Reports Server (NTRS)
Arbocz, Johann; Hilburger, Mark W.
2003-01-01
A probability-based analysis method for predicting buckling loads of compression-loaded laminated-composite shells is presented, and its potential as a basis for a new shell-stability design criterion is demonstrated and discussed. In particular, a database containing information about specimen geometry, material properties, and measured initial geometric imperfections for a selected group of laminated-composite cylindrical shells is used to calculate new buckling-load "knockdown factors". These knockdown factors are shown to be substantially improved, and hence much less conservative than the corresponding deterministic knockdown factors that are presently used by industry. The probability integral associated with the analysis is evaluated by using two methods; that is, by using the exact Monte Carlo method and by using an approximate First-Order Second- Moment method. A comparison of the results from these two methods indicates that the First-Order Second-Moment method yields results that are conservative for the shells considered. Furthermore, the results show that the improved, reliability-based knockdown factor presented always yields a safe estimate of the buckling load for the shells examined.
Tree-based modeling of complex interactions of phosphorus loadings and environmental factors.
Grunwald, S; Daroub, S H; Lang, T A; Diaz, O A
2009-06-01
Phosphorus (P) enrichment has been observed in the historic oligotrophic Greater Everglades in Florida mainly due to P influx from upstream, agriculturally dominated, low relief drainage basins of the Everglades Agricultural Area (EAA). Our specific objectives were to: (1) investigate relationships between various environmental factors and P loads in 10 farm basins within the EAA, (2) identify those environmental factors that impart major effects on P loads using three different tree-based modeling approaches, and (3) evaluate predictive models to assess P loads. We assembled thirteen environmental variable sets for all 10 sub-basins characterizing water level management, cropping practices, soils, hydrology, and farm-specific properties. Drainage flow and P concentrations were measured at each sub-basin outlet from 1992-2002 and aggregated to derive monthly P loads. We used three different tree-based models including single regression trees (ST), committee trees in Bagging (CTb) and ARCing (CTa) modes and ten-fold cross-validation to test prediction performances. The monthly P loads (MPL) during the monitoring period showed a maximum of 2528 kg (mean: 103 kg) and maximum monthly unit area P loads (UAL) of 4.88 kg P ha(-1) (mean: 0.16 kg P ha(-1)). Our results suggest that hydrologic/water management properties are the major controlling variables to predict MPL and UAL in the EAA. Tree-based modeling was successful in identifying relationships between P loads and environmental predictor variables on 10 farms in the EAA indicated by high R(2) (>0.80) and low prediction errors. Committee trees in ARCing mode generated the best performing models to predict P loads and P loads per unit area. Tree-based models had the ability to analyze complex, non-linear relationships between P loads and multiple variables describing hydrologic/water management, cropping practices, soil and farm-specific properties within the EAA.
Short rest between cyclic flexion periods is a risk factor for a lumbar disorder.
Hoops, Heather; Zhou, Bing-He; Lu, Yun; Solomonow, Moshe; Patel, Vikas
2007-08-01
The epidemiology identifies cyclic lumbar loading as a risk factor for cumulative trauma disorder. Experimental biomechanical and physiological confirmation is lacking. The objective of this study was to asses the impact of different rest durations applied between periods of cyclic loading on the development of an acute lumbar disorder which, if continued to be subjected to loading, may develop into a cumulative disorder. Three groups of in vivo feline preparations were subjected to six sequential 10 min loading periods of cyclic lumbar flexion at 40 N with a frequency of 0.25 Hz applied to the L-4/5 level. The rest durations varied from 5 min in the first group, to 10 min in the second and to 20 min in the third. Reflexive EMG from the multifidi and lumbar displacement were used to identify significant (P<0.001) effects of time and rest duration for post-load EMG and displacement. Single-cycle test were performed hourly for 7 h post-loading to assess recovery. A model developed earlier was applied to represent the experimental data. The groups allowed 5 and 10 min rest exhibited an acute neuromuscular disorder expressed by a significant (P<0.001) delayed hyperexcitability 2-3 h into the 7 h recovery period with the intensity of the hyperexcitability significantly higher (P<0.001) for the group allowed only 5 min rest. The group allowed 20 min rest had a slow, uneventful recovery, free of delayed hyperexcitability. Occupational and sports activities requiring repetitive (cyclic) loading of the lumbar spine may be a risk factor for the development of a cumulative lumbar disorder and may require sufficient rest, as much as twice as long as the loading period, for prevention. Comparison to similar data for static lumbar loading shows that cyclic loading is more deleterious than static loading, requiring more rest to offset the negative effect of the repeated acts of stretch.
Ribeiro, Ana Paula; João, Silvia Maria Amado; Dinato, Roberto Casanova; Tessutti, Vitor Daniel; Sacco, Isabel Camargo Neves
2015-01-01
Aim/Hypothesis The etiology of plantar fasciitis (PF) has been related to several risk factors, but the magnitude of the plantar load is the most commonly described factor. Although PF is the third most-common injury in runners, only two studies have investigated this factor in runners, and their results are still inconclusive regarding the injury stage. Objective Analyze and compare the plantar loads and vertical loading rate during running of runners in the acute stage of PF to those in the chronic stage of the injury in relation to healthy runners. Methods Forty-five runners with unilateral PF (30 acute and 15 chronic) and 30 healthy control runners were evaluated while running at 12 km/h for 40 meters wearing standardized running shoes and Pedar-X insoles. The contact area and time, maximum force, and force-time integral over the rearfoot, midfoot, and forefoot were recorded and the loading rate (20–80% of the first vertical peak) was calculated. Groups were compared by ANOVAs (p<0.05). Results Maximum force and force-time integral over the rearfoot and the loading rate was higher in runners with PF (acute and chronic) compared with controls (p<0.01). Runners with PF in the acute stage showed lower loading rate and maximum force over the rearfoot compared to runners in the chronic stage (p<0.01). Conclusion Runners with PF showed different dynamic patterns of plantar loads during running over the rearfoot area depending on the injury stage (acute or chronic). In the acute stage of PF, runners presented lower loading rate and forces over the rearfoot, possibly due to dynamic mechanisms related to pain protection of the calcaneal area. PMID:26375815
Psychosocial factors and mental work load: a reality perceived by nurses in intensive care units1
Ceballos-Vásquez, Paula; Rolo-González, Gladys; Hérnandez-Fernaud, Estefanía; Díaz-Cabrera, Dolores; Paravic-Klijn, Tatiana; Burgos-Moreno, Mónica
2015-01-01
OBJECTIVE: To analyse the perception of psychosocial factors and mental workload of nurses who work in intensive care units. It is hypothesised that nurses in these units could perceive psychosocial risks, manifesting in a high mental work load. The psychosocial dimension related to the position's cognitive demands is hypothesised to mostly explain mental work load. METHOD: Quantitative study, with a descriptive, cross-sectional, and comparative design. A total of 91% of the intensive care unit populations of three Chilean hospitals was surveyed, corresponding to 111 nurses. The instruments utilised included (A) a biosociodemographic history questionnaire; (b) the SUSESO-ISTAS 21 questionnaire; and (c) the Mental Work Load Subjective Scale (ESCAM, in Spanish). RESULTS: In total, 64% and 57% of participants perceived high levels of exposure to the psychosocial risks Psychosocial demands and Double shift, respectively. In addition, a medium-high level of overall mental load was observed. Positive and significant correlations between some of the SUSESO-ISTAS 21 and ESCAM dimensions were obtained. Using a regression analysis, it was determined that three dimensions of the psychosocial risk questionnaire helped to explain 38% of the overall mental load. CONCLUSION: Intensive care unit nurses felt that inadequate psychosocial factors and mental work overload existed in several of the tested dimensions. PMID:26039303
The Influence of Cognitive Load on Empathy and Intention in Response to Infant Crying.
Hiraoka, Daiki; Nomura, Michio
2016-06-16
Many studies have explored risk factors for child maltreatment, but little research has focused on situational risk factors such as cognitive load, which involves within-individual fluctuation. The current study sought to determine whether cognitive load led to within-individual changes in intention in response to infant crying. The study also sought to ascertain whether state empathy, empathic concern (EC), and personal distress mediated or moderated this relationship. Sixty-six participants completed a memory task (remembering meaningless, two- or eight-letter, English alphabet string), during which they were required to keep these letters in mind while hearing infant crying (or a tone). Subsequently, participants rated questions concerning state empathy and intention in response to the crying (i.e., intentions involving caregiving, neglect, or physical abuse). Results showed that cognitive load reduced caregiving intention and increased intention to perpetrate neglect. In addition, EC mediated the relationship between cognitive load and intention to provide care or perpetrate neglect. Moreover, cognitive load interacted with state empathy to predict intention to provide care or perpetrate neglect. These findings highlighted the importance of focusing on situational cognitive risk factors for child maltreatment and elucidated the role of state empathy as a mediator or moderator in child maltreatment research.
The Influence of Cognitive Load on Empathy and Intention in Response to Infant Crying
Hiraoka, Daiki; Nomura, Michio
2016-01-01
Many studies have explored risk factors for child maltreatment, but little research has focused on situational risk factors such as cognitive load, which involves within-individual fluctuation. The current study sought to determine whether cognitive load led to within-individual changes in intention in response to infant crying. The study also sought to ascertain whether state empathy, empathic concern (EC), and personal distress mediated or moderated this relationship. Sixty-six participants completed a memory task (remembering meaningless, two- or eight-letter, English alphabet string), during which they were required to keep these letters in mind while hearing infant crying (or a tone). Subsequently, participants rated questions concerning state empathy and intention in response to the crying (i.e., intentions involving caregiving, neglect, or physical abuse). Results showed that cognitive load reduced caregiving intention and increased intention to perpetrate neglect. In addition, EC mediated the relationship between cognitive load and intention to provide care or perpetrate neglect. Moreover, cognitive load interacted with state empathy to predict intention to provide care or perpetrate neglect. These findings highlighted the importance of focusing on situational cognitive risk factors for child maltreatment and elucidated the role of state empathy as a mediator or moderator in child maltreatment research. PMID:27305959
Psychosocial factors and mental work load: a reality perceived by nurses in intensive care units.
Ceballos-Vásquez, Paula; Rolo-González, Gladys; Hérnandez-Fernaud, Estefanía; Díaz-Cabrera, Dolores; Paravic-Klijn, Tatiana; Burgos-Moreno, Mónica
2015-01-01
To analyse the perception of psychosocial factors and mental workload of nurses who work in intensive care units. It is hypothesised that nurses in these units could perceive psychosocial risks, manifesting in a high mental work load. The psychosocial dimension related to the position's cognitive demands is hypothesised to mostly explain mental work load. Quantitative study, with a descriptive, cross-sectional, and comparative design. A total of 91% of the intensive care unit populations of three Chilean hospitals was surveyed, corresponding to 111 nurses. The instruments utilised included (A) a biosociodemographic history questionnaire; (b) the SUSESO-ISTAS 21 questionnaire; and (c) the Mental Work Load Subjective Scale (ESCAM, in Spanish). In total, 64% and 57% of participants perceived high levels of exposure to the psychosocial risks Psychosocial demands and Double shift, respectively. In addition, a medium-high level of overall mental load was observed. Positive and significant correlations between some of the SUSESO-ISTAS 21 and ESCAM dimensions were obtained. Using a regression analysis, it was determined that three dimensions of the psychosocial risk questionnaire helped to explain 38% of the overall mental load. Intensive care unit nurses felt that inadequate psychosocial factors and mental work overload existed in several of the tested dimensions.
NASA Astrophysics Data System (ADS)
Khalili, S. M. R.; Shariyat, M.; Mokhtari, M.
2014-06-01
In this study, the central cracked aluminum plates repaired with two sided composite patches are investigated numerically for their response to static tensile and transient dynamic loadings. Contour integral method is used to define and evaluate the stress intensity factors at the crack tips. The reinforcement for the composite patches is carbon fibers. The effect of adhesive thickness and patch thickness and configuration in tensile loading case and pre-tension, pre-compression and crack length effect on the evolution of the mode I stress intensity factor (SIF) (KI) of the repaired structure under transient dynamic loading case are examined. The results indicated that KI of the central cracked plate is reduced by 1/10 to 1/2 as a result of the bonded composite patch repair in tensile loading case. The crack length and the pre-loads are more effective in repaired structure in transient dynamic loading case in which, the 100 N pre-compression reduces the maximum KI for about 40 %, and the 100 N pre-tension reduces the maximum KI after loading period, by about 196 %.
A comparison of three methods for classifying fuel loads in the Southern Appalachian Mountains
Lucy Brudnak; Thomas A. Waldrop; Sandra Rideout-Hanzak
2006-01-01
As the wildland-urban interface in the Southern Appalachian Mountains has grown and become more complex, land managers, property owners, and ecologists have found it increasingly necessary to understand factors that drive fuel loading. Few predictive fuel loading models have been created for this important region. Three approaches to estimating fuel loads are compared...
Optimization of Nanowire-Resistance Load Logic Inverter.
Hashim, Yasir; Sidek, Othman
2015-09-01
This study is the first to demonstrate characteristics optimization of nanowire resistance load inverter. Noise margins and inflection voltage of transfer characteristics are used as limiting factors in this optimization. Results indicate that optimization depends on resistance value. Increasing of load resistor tends to increasing in noise margins until saturation point, increasing load resistor after this point will not improve noise margins significantly.
Iron does not cause arrhythmias in the guinea pig model of transfusional iron overload.
Kaiser, Lana; Davis, John; Patterson, Jon; Boyd, Ryan F; Olivier, N Bari; Bohart, George; Schwartz, Kenneth A
2007-08-01
Cardiac events, including heart failure and arrhythmias, are the leading cause of death in patients with beta thalassemia. Although cardiac arrhythmias in humans are believed to result from iron overload, excluding confounding factors in the human population is difficult. The goal of the current study was to determine whether cardiac arrhythmias occurred in the guinea pig model of secondary iron overload. Electrocardiograms were recorded by using surgically implanted telemetry devices in guinea pigs loaded intraperitoneally with iron dextran (test animals) or dextran alone (controls). Loading occurred over approximately 6 wk. Electrocardiograms were recorded for 1 wk prior to loading, throughout loading, and for approximately 4 wk after loading was complete. Cardiac and liver iron concentrations were significantly increased in the iron-loaded animals compared with controls and were in the range of those reported for humans with thalassemia. Arrhythmias were rare in both iron-loaded and control guinea pigs. No life-threatening arrhythmias were detected in either group. These data suggest that iron alone may be insufficient to cause cardiac arrhythmias in the iron-loaded guinea pig model and that arrhythmias detected in human patients with iron overload may be the result of a complex interplay of factors.
The effect of mechanical loads on the degradation of aliphatic biodegradable polyesters.
Li, Ying; Chu, Zhaowei; Li, Xiaoming; Ding, Xili; Guo, Meng; Zhao, Haoran; Yao, Jie; Wang, Lizhen; Cai, Qiang; Fan, Yubo
2017-06-01
Aliphatic biodegradable polyesters have been the most widely used synthetic polymers for developing biodegradable devices as alternatives for the currently used permanent medical devices. The performances during biodegradation process play crucial roles for final realization of their functions. Because physiological and biochemical environment in vivo significantly affects biodegradation process, large numbers of studies on effects of mechanical loads on the degradation of aliphatic biodegradable polyesters have been launched during last decades. In this review article, we discussed the mechanism of biodegradation and several different mechanical loads that have been reported to affect the biodegradation process. Other physiological and biochemical factors related to mechanical loads were also discussed. The mechanical load could change the conformational strain energy and morphology to weaken the stability of the polymer. Besides, the load and pattern could accelerate the loss of intrinsic mechanical properties of polymers. This indicated that investigations into effects of mechanical loads on the degradation should be indispensable. More combination condition of mechanical loads and multiple factors should be considered in order to keep the degradation rate controllable and evaluate the degradation process in vivo accurately. Only then can the degradable devise achieve the desired effects and further expand the special applications of aliphatic biodegradable polyesters.
Vibration of high-voltage electric machines with rotors on rolling bearings
NASA Astrophysics Data System (ADS)
Shekyan, H. G.; Gevorgyan, A. V.
2018-04-01
The paper presents an investigation of vibrational activity of electric machines due to high-harmonic vibrational loadings. It is shown that the vibrational loadings experienced by bearings may result in the interruption of their normal operation and even take them out of action. Therefore, the values of the vibrational speed-up leading to high harmonics are factors determining the admissible dynamic loading on the bearings. In the paper, an attempt is made to consider the factors which result in origination of high harmonics and to illustrate methods for their smoothing.
Mynarek, Martin; Ganzenmueller, Tina; Mueller-Heine, Annika; Mielke, Christopher; Gonnermann, Andrea; Beier, Rita; Sauer, Martin; Eiz-Vesper, Britta; Kohstall, Ute; Sykora, Karl-Walter; Heim, Albert; Maecker-Kolhoff, Britta
2014-02-01
Human adenovirus (HAdV) infection after hematopoietic stem cell transplantation (HSCT) is associated with significant morbidity and mortality in children. The optimal surveillance and treatment strategies are under discussion. Here, we present data from 238 consecutive pediatric allogeneic HSCT recipients who underwent transplantation in a single center who were included in a prospective, weekly HAdV DNAemia monitoring program by quantitative PCR. HAdV loads >1000 copies/mL were detected in 15.5% of all patients. Despite a low mortality directly attributed to HAdV infection (2 patients, 0.84%), blood HAdV loads >10,000 copies/mL (6.7% of all patients) were significant and independent risk factors for poor survival. We searched for patient, virus, and treatment-related risk factors of HAdV DNAemia and disease. Detection of HAdV in blood before day 50 post transplantation was a major independent risk factor for the development of blood HAdV loads >10,000 copies/mL. HAdV typing revealed A31, C1, and C2 as the predominant pathogens among several other HAdV strains with type C species detected in most patients with severe HAdV disease. Stool HAdV loads were prospectively monitored in 111 patients and correlated with but did not significantly precede detection in blood. Treatment with cidofovir led to stable or reduced viral load in 70% of patients with blood HAdV loads >1000 copies/mL. Thus, early occurrence of HAdV-DNA in blood of pediatric HSCT recipients predisposes for development of high viral loads. Control of HAdV infections was attempted by preemptive cidofovir treatment of patients with high blood HAdV loads or with symptomatic organ infections and correlated with low HAdV-attributed mortality. Copyright © 2014 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Wargo, Andrew R.; Kell, Alison M.; Scott, Robert J.; Thorgaard, Gary H.; Kurath, Gael
2012-01-01
Little is known about the factors that drive the high levels of between-host variation in pathogen burden that are frequently observed in viral infections. Here, two factors thought to impact viral load variability, host genetic diversity and stochastic processes linked with viral entry into the host, were examined. This work was conducted with the aquatic vertebrate virus, Infectious hematopoietic necrosis virus (IHNV), in its natural host, rainbow trout. It was found that in controlled in vivo infections of IHNV, a suggestive trend of reduced between-fish viral load variation was observed in a clonal population of isogenic trout compared to a genetically diverse population of out-bred trout. However, this trend was not statistically significant for any of the four viral genotypes examined, and high levels of fish-to-fish variation persisted even in the isogenic trout population. A decrease in fish-to-fish viral load variation was also observed in virus injection challenges that bypassed the host entry step, compared to fish exposed to the virus through the natural water-borne immersion route of infection. This trend was significant for three of the four virus genotypes examined and suggests host entry may play a role in viral load variability. However, high levels of viral load variation also remained in the injection challenges. Together, these results indicate that although host genetic diversity and viral entry may play some role in between-fish viral load variation, they are not major factors. Other biological and non-biological parameters that may influence viral load variation are discussed.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Flight Loads § 23.321 General. (a) Flight load factors represent the ratio of the aerodynamic force component (acting normal to... distribution of disposable load within the operating limitations specified in §§ 23.1583 through 23.1589. (c...
Spool assembly support analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Norman, B.F.
1994-10-07
This document provides the wind/seismic analysis and evaluation for the pump pit spool assemblies. Hand calculations were used for the analysis. UBC, AISC, and load factors were used in this evaluation. The results show that the actual loads are under the allowable loads and all requirements are met.
Embedded data collector (EDC) phase II load and resistance factor design (LRFD).
DOT National Transportation Integrated Search
2015-09-01
A total of 16 static load test results was collected in Florida and Louisiana. New static load tests on five test piles : in Florida (four of which were voided) were monitored with Embedded Data Collector (EDC) instrumentation and : contributed to th...
Chen, Youzhen; Lian, Rong; Yang, Lixian; Liu, Jianrong; Meng, Yingfang
The effects of working memory (WM) demand and reminders on an event-based prospective memory (PM) task were compared between students with low and high achievement in math. WM load (1- and 2-back tasks) was manipulated as a within-subject factor and reminder (with or without reminder) as a between-subject factor. Results showed that high-achieving students outperformed low-achieving students on all PM and n-back tasks. Use of a reminder improved PM performance and thus reduced prospective interference; the performance of ongoing tasks also improved for all students. Both PM and n-back performances in low WM load were better than in high WM load. High WM load had more influence on low-achieving students than on high-achieving students. Results suggest that low-achieving students in math were weak at PM and influenced more by high WM load. Thus, it is important to train these students to set up an obvious reminder for their PM and improve their WM.
Determination of stress intensity factors for interface cracks under mixed-mode loading
NASA Technical Reports Server (NTRS)
Naik, Rajiv A.; Crews, John H., Jr.
1992-01-01
A simple technique was developed using conventional finite element analysis to determine stress intensity factors, K1 and K2, for interface cracks under mixed-mode loading. This technique involves the calculation of crack tip stresses using non-singular finite elements. These stresses are then combined and used in a linear regression procedure to calculate K1 and K2. The technique was demonstrated by calculating three different bimaterial combinations. For the normal loading case, the K's were within 2.6 percent of an exact solution. The normalized K's under shear loading were shown to be related to the normalized K's under normal loading. Based on these relations, a simple equation was derived for calculating K1 and K2 for mixed-mode loading from knowledge of the K's under normal loading. The equation was verified by computing the K's for a mixed-mode case with equal and normal shear loading. The correlation between exact and finite element solutions is within 3.7 percent. This study provides a simple procedure to compute K2/K1 ratio which has been used to characterize the stress state at the crack tip for various combinations of materials and loadings. Tests conducted over a range of K2/K1 ratios could be used to fully characterize interface fracture toughness.
Temperature effects on ash physical and chemical properties. A laboratory study.
NASA Astrophysics Data System (ADS)
Pereira, Paulo; Úbeda, Xavier; Martin, Deborah
2010-05-01
Fire temperatures have different impacts on ash physical and chemical properties that depend mainly of the specie affected and time of exposition. In a real prescribed or wildland fire, the temperatures produce ash with different characteristics. Know the impacts of a specific temperature or a gradient on a certain element and specie is very difficult in real fires, especially in wildland fires, where temperatures achieve higher values and the burning conditions are not controlled. Hence, laboratory studies revealed to be an excellent methodology to understand the effects of fire temperatures in ash physical and chemical. The aim of this study is study the effects of a temperature gradient (150, 200, 250, 300, 350, 400, 450, 500 and 550°C) on ash physical and chemical properties. For this study we collected litter of Quercus suber, Pinus pinea and Pinus pinaster in a plot located in Portugal. The selected species are the most common in the ecosystem. We submitted samples to the mentioned temperatures throughout a time of two hours and we analysed several parameters, namely, Loss on Ignition (LOI%), ash colour - through the Croma Value (CV) observed in Munsell color chart - CaCO3, Total Nitrogen (TN), Total Carbon (TC), C/N ratio, ash pH, Electrical Conductivity (EC), extractable Calcium (Ca2+), Magnesium (Mg2+), Sodium (Na+), Potassium (K+), Aluminium (Al3+), Manganese (Mn2+), Iron (Fe2+), Zinc (Zn2+), Total Phosphorous (TP), Sulphur (S) and Silica (SiO2). Since we considered many elements, in order to obtain a better explanation of all dataset, we applied a Factorial Analysis (FA), based on the correlation matrix and the Factors were extracted according to the Principle Components method. To obtain a better relation between the variables with a specific Factor we rotated the matrix according to the VARIMAX NORMALIZED method. FA identified 5 Factors that explained a total of 95% of the variance. We retained in each Factor the variables that presented an eigenvalue >0.7. Factor 1 explained the majority of the variance (60.05%). LOI(%), CV, CaCO3, pH, Na+, K+, S (these last tree elements only in both Pinus) and SiO2, showed positive loadings. Inversely, TC, C/N ratio, Al3+, Fe2+ (these last tree elements for Quercus suber and Pinus pinaster ash) and Mn2+ (In the case of Quercus suber) presented negative loadings. Factor 2 explained 19.89% of the variance and showed higher loadings in TN, Ca2+ and Mg2+ (in the case of the ions only in both Pinus). Factor 3 explains only 6.69% of the variance and we identified higher loadings in Mg2+, Na+ and K+ of Quercus suber. Factor 4 explains less then the last Factor, only 4.60% of the variance and presented negative loadings above -0.7 in TP of Quercus suber and Pinus pinea. Factor 5 explained 3.93% of the variance, less than all other Factors and showed in Al3+, Mn2+ and Zn2+ of Pinus pinea and in the case of the last element, also in Pinus pinaster. The observation of the scores matrix allowed us to understand the major concentration of these elements according the temperature of exposition. Hence, the elements that showed higher positive loadings in Factor 1, have a major concentration at 450, 500 and 550°C, and the ones with higher negative loadings presented higher concentration at 200 and 250°C. The nutrients that presented higher positive loadings in Factor 2 have higher concentrations at 400°C. The elements with higher positive loadings in Factor 3 have bigger amounts in the ash slurries produced at 350°C and the ones with higher negative loadings in the Factor 4 showed greater concentrations in the ash produced at 300°C. The elements with higher negative loadings in the Factor 5 showed higher amounts in the ash created at 150°C of exposition. The results obtained showed that nutrients concentration is a function of the burned specie and temperature reached in the considered exposure time. Micronutrients and TC and C/N showed higher values at lower temperatures, TN, Ca2+, Mg2+ and TP at temperatures between 300-400°C. The other variables in study have major concentrations at temperatures higher than 450°C. Some differences between species can be identified and this is a result of the different litter vulnerabilities to the same temperature, producing diverse fire severities. This and other reasons for this behaviour will be discussed in the communication.
Wind Loads on Flat Plate Photovoltaic Array Fields
NASA Technical Reports Server (NTRS)
Miller, R.; Zimmerman, D.
1979-01-01
The aerodynamic forces resulting from winds acting on flat plate photovoltaic arrays were investigated. Local pressure distributions and total aerodynamic forces on the arrays are shown. Design loads are presented to cover the conditions of array angles relative to the ground from 20 deg to 60 deg, variable array spacings, a ground clearance gap up to 1.2 m (4 ft) and array slant heights of 2.4 m (8 ft) and 4.8 m (16 ft). Several means of alleviating the wind loads on the arrays are detailed. The expected reduction of the steady state wind velocity with the use of fences as a load alleviation device are indicated to be in excess of a factor of three for some conditions. This yields steady state wind load reductions as much as a factor of ten compared to the load incurred if no fence is used to protect the arrays. This steady state wind load reduction is offset by the increase in turbulence due to the fence but still an overall load reduction of 2.5 can be realized. Other load alleviation devices suggested are the installation of air gaps in the arrays, blocking the flow under the arrays and rounding the edges of the array. A wind tunnel test plan to supplement the theoretical study and to evaluate the load alleviation devices is outlined.
Mosaly, Prithima R; Mazur, Lukasz M; Marks, Lawrence B
2017-10-01
The methods employed to quantify the baseline pupil size and task-evoked pupillary response (TEPR) may affect the overall study results. To test this hypothesis, the objective of this study was to assess variability in baseline pupil size and TEPR during two basic working memory tasks: constant load of 3-letters memorisation-recall (10 trials), and incremental load memorisation-recall (two trials of each load level), using two commonly used methods (1) change from trail/load specific baseline, (2) change from constant baseline. Results indicated that there was a significant shift in baseline between the trails for constant load, and between the load levels for incremental load. The TEPR was independent of shifts in baseline using method 1 only for constant load, and method 2 only for higher levels of incremental load condition. These important findings suggest that the assessment of both the baseline and methods to quantify TEPR are critical in ergonomics application, especially in studies with small number of trials per subject per condition. Practitioner Summary: Quantification of TEPR can be affected by shifts in baseline pupil size that are most likely affected by non-cognitive factors when other external factors are kept constant. Therefore, quantification methods employed to compute both baseline and TEPR are critical in understanding the information processing of humans in practical ergonomics settings.
14 CFR 25.365 - Pressurized compartment loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
... multiplied by a factor of 1.33 for airplanes to be approved for operation to 45,000 feet or by a factor of 1.67 for airplanes to be approved for operation above 45,000 feet, omitting other loads. (e) Any... an engine disintegration; (2) Any opening in any pressurized compartment up to the size Ho in square...
Applying Cognitive Load Theory Principles to Library Instructional Guidance
ERIC Educational Resources Information Center
Pickens, Kathleen E.
2017-01-01
If the goal of library instructional guidance is to provide students with the knowledge needed to acquire new skills in order to accomplish their learning objectives, then it is prudent to consider factors that impact learning. Cognitive load theory addresses several of these factors and is applicable to a wide-range of instructional devices used…
ERIC Educational Resources Information Center
Reker, Gary T.; Cousins, J. B.
1979-01-01
In this study with 240 introductory psychology students, ten interpretable independent dimensions of satisfaction with life were extracted with six factors that loaded on the PIL and four that loaded on the SONG, supporting Crumbaugh's assertion that the SONG is a complementary scale to the PIL. (Author/SJL)
NASA Technical Reports Server (NTRS)
Gordon, S. E.; Fluck, M.; Booth, F. W.
2001-01-01
This investigation examined the effect of mechanical loading state on focal adhesion kinase (FAK), paxillin, and serum response factor (SRF) in rat skeletal muscle. We found that FAK concentration and tyrosine phosphorylation, paxillin concentration, and SRF concentration are all lower in the lesser load-bearing fast-twitch plantaris and gastrocnemius muscles compared with the greater load-bearing slow-twitch soleus muscle. Of these three muscles, 7 days of mechanical unloading via tail suspension elicited a decrease in FAK tyrosine phosphorylation only in the soleus muscle and decreases in FAK and paxillin concentrations only in the plantaris and gastrocnemius muscles. Unloading decreased SRF concentration in all three muscles. Mechanical overloading (via bilateral gastrocnemius ablation) for 1 or 8 days increased FAK and paxillin concentrations in the soleus and plantaris muscles. Additionally, whereas FAK tyrosine phosphorylation and SRF concentration were increased by < or =1 day of overloading in the soleus muscle, these increases did not occur until somewhere between 1 and 8 days of overloading in the plantaris muscle. These data indicate that, in the skeletal muscles of rats, the focal adhesion complex proteins FAK and paxillin and the transcription factor SRF are generally modulated in association with the mechanical loading state of the muscle. However, the somewhat different patterns of adaptation of these proteins to altered loading in slow- vs. fast-twitch skeletal muscles indicate that the mechanisms and time course of adaptation may partly depend on the prior loading state of the muscle.
Is Hand Selection Modulated by Cognitive-perceptual Load?
Liang, Jiali; Wilkinson, Krista; Sainburg, Robert L
2018-01-15
Previous studies proposed that selecting which hand to use for a reaching task appears to be modulated by a factor described as "task difficulty". However, what features of a task might contribute to greater or lesser "difficulty" in the context of hand selection decisions has yet to be determined. There has been evidence that biomechanical and kinematic factors such as movement smoothness and work can predict patterns of selection across the workspace, suggesting a role of predictive cost analysis in hand-selection. We hypothesize that this type of prediction for hand-selection should recruit substantial cognitive resources and thus should be influenced by cognitive-perceptual loading. We test this hypothesis by assessing the role of cognitive-perceptual loading on hand selection decisions, using a visual search task that presents different levels of difficulty (cognitive-perceptual load), as established in previous studies on overall response time and efficiency of visual search. Although the data are necessarily preliminary due to small sample size, our data suggested an influence of cognitive-perceptual load on hand selection, such that the dominant hand was selected more frequently as cognitive load increased. Interestingly, cognitive-perceptual loading also increased cross-midline reaches with both hands. Because crossing midline is more costly in terms of kinematic and kinetic factors, our findings suggest that cognitive processes are normally engaged to avoid costly actions, and that the choice not-to-cross midline requires cognitive resources. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.
Can physical activity improve peak bone mass?
Specker, Bonny; Minett, Maggie
2013-09-01
The pediatric origin of osteoporosis has led many investigators to focus on determining factors that influence bone gain during growth and methods for optimizing this gain. Bone responds to bone loading activities by increasing mass or size. Overall, pediatric studies have found a positive effect of bone loading on bone size and accrual, but the types of loads necessary for a bone response have only recently been investigated in human studies. Findings indicate that responses vary by sex, maturational status, and are site-specific. Estrogen status, body composition, and nutritional status also may influence the bone response to loading. Despite the complex interrelationships among these various factors, it is prudent to conclude that increased physical activity throughout life is likely to optimize bone health.
Study on Impact of Electric Vehicles Charging Models on Power Load
NASA Astrophysics Data System (ADS)
Cheng, Chen; Hui-mei, Yuan
2017-05-01
With the rapid increase in the number of electric vehicles, which will lead the power load on grid increased and have an adversely affect. This paper gives a detailed analysis of the following factors, such as scale of the electric cars, charging mode, initial charging time, initial state of charge, charging power and other factors. Monte Carlo simulation method is used to compare the two charging modes, which are conventional charging and fast charging, and MATLAB is used to model and simulate the electric vehicle charging load. The results show that compared with the conventional charging mode, fast charging mode can meet the requirements of fast charging, but also bring great load to the distribution network which will affect the reliability of power grid.
Stress intensity factors for surface and corner cracks emanating from a wedge-loaded hole
NASA Technical Reports Server (NTRS)
Zhao, W.; Sutton, M. A.; Shivakumar, K. N.; Newman, J. C., Jr.
1994-01-01
To assist analysis of riveted lap joints, stress intensity factors are determined for surface and corner cracks emanating from a wedge-loaded hole by using a 3-D weight function method in conjunction with a 3-D finite element method. A stress intensity factor equation for surface cracks is also developed to provide a closed-form solution. The equation covers commonly-encountered geometrical ranges and retains high accuracy over the entire range.
NASA Astrophysics Data System (ADS)
Demir, Ozgur; Sahin, Abdurrahman; Yilmaz, Tamer
2012-09-01
Underwater explosion induced shock loads are capable of causing considerable structural damage. Investigations of the underwater explosion (UNDEX) effects on structures have seen continuous developments because of security risks. Most of the earlier experimental investigations were performed by military since the World War I. Subsequently; Cole [1] established mathematical relations for modeling underwater explosion shock loading, which were the outcome of many experimental investigations This study predicts and establishes the transient responses of a panel structure to underwater explosion shock loads using non-linear finite element code Ls-Dyna. Accordingly, in this study a new MATLAB code has been developed for predicting shock loading profile for different weight of explosive and different shock factors. Numerical analysis was performed for various test conditions and results are compared with Ramajeyathilagam's experimental study [8].
Dynamic Load on Continuous Multi-Lane Bridge Deck from Moving Vehicles
NASA Astrophysics Data System (ADS)
ZHU, X. Q.; LAW, S. S.
2002-04-01
The dynamic loading on a multi-lane continuous bridge deck due to vehicles moving on top at a constant velocity is investigated. The bridge is modelled as a multi-span continuous orthotropic rectangular plate with line rigid intermediate supports. The vehicle is simulated as a two-axle three-dimensional vehicle model with seven degrees of freedom according to the H20-44 vehicle design loading (AASHTO LRFD Bridge Design Specifications 1998 American Association of State Highway and Transportation Officials [1]). The dynamic behavior of the bridge deck under single and several vehicles moving in different lanes is analyzed using the orthotropic plate theory and modal superposition technique. The dynamic loading is studied in terms of the dynamic impact factor of the bridge deck. The impact factor is found varying in an opposite trend as the dynamic responses for the different loading cases under study.
NASA Technical Reports Server (NTRS)
Amtmann, E.; Kimura, T.; Oyama, J.; Doden, E.; Potulski, M.
1979-01-01
At the age of 30 days female Sprague-Dawley rats were placed on a 3.66 m radius centrifuge and subsequently exposed almost continuously for 810 days to either 2.76 or 4.15 G. An age-matched control group of rats was raised near the centrifuge facility at earth gravity. Three further control groups of rats were obtained from the animal colony and sacrificed at the age of 34, 72 and 102 days. A total of 16 variables were simultaneously factor analyzed by maximum-likelihood extraction routine and the factor loadings presented after-rotation to simple structure by a varimax rotation routine. The variables include the G-load, age, body mass, femoral length and cross-sectional area, inner and outer radii, density and strength at the mid-length of the femur, dry weight of gluteus medius, semimenbranosus and triceps surae muscles. Factor analyses on A) all controls, B) all controls and the 2.76 G group, and C) all controls and centrifuged animals, produced highly similar loading structures of three common factors which accounted for 74%, 68% and 68%. respectively, of the total variance. The 3 factors were interpreted as: 1. An age and size factor which stimulates the growth in length and diameter and increases the density and strength of the femur. This factor is positively correlated with G-load but is also active in the control animals living at earth gravity. 2. A growth inhibition factor which acts on body size, femoral length and on both the outer and inner radius at mid-length of the femur. This factor is intensified by centrifugation.
Genetic Factors Affecting Late-Onset Alzheimer's Disease Susceptibility.
Rezazadeh, Maryam; Khorrami, Aziz; Yeghaneh, Tarlan; Talebi, Mahnaz; Kiani, Seyed Jalal; Heshmati, Yaser; Gharesouran, Jalal
2016-03-01
Alzheimer's disease is considered a progressive brain disease in the older population. Late-onset Alzheimer's disease (LOAD) as a multifactorial dementia has a polygenic inheritance. Age, environment, and lifestyle along with a growing number of genetic factors have been reported as risk factors for LOAD. Our aim was to present results of LOAD association studies that have been done in northwestern Iran, and we also explored possible interactions with apolipoprotein E (APOE) status. We re-evaluated the association of these markers in dominant, recessive, and additive models. In all, 160 LOAD and 163 healthy control subjects of Azeri Turkish ethnicity were studied. The Chi-square test with Yates' correction and Fisher's exact test were used for statistical analysis. A Bonferroni-corrected p value, based on the number of statistical tests, was considered significant. Our results confirmed that chemokine receptor type 2 (CCR2), estrogen receptor 1 (ESR1), toll-like receptor 2 (TLR2), tumor necrosis factor alpha (TNF α), APOE, bridging integrator 1 (BIN1), and phosphatidylinositol-binding clathrin assembly protein (PICALM) are LOAD susceptibility loci in Azeri Turk ancestry populations. Among them, variants of CCR2, ESR1, TNF α, and APOE revealed associations in three different genetic models. After adjusting for APOE, the association (both allelic and genotypic) with CCR2, BIN1, and ESRα (PvuII) was evident only among subjects without the APOE ε4, whereas the association with CCR5, without Bonferroni correction, was significant only among subjects carrying the APOE ε4 allele. This result is an evidence of a synergistic and antagonistic effect of APOE on variant associations with LOAD.
The Extravehicular Suit Impact Load Attenuation Study for Use in Astronaut Bone Fracture Prediction
NASA Technical Reports Server (NTRS)
Lewandowski, Beth E.; Gilkey, Kelly M.; Sulkowski, Christina M.; Samorezov, Sergey; Myers, Jerry G.
2011-01-01
The NASA Integrated Medical Model (IMM) assesses the risk, including likelihood and impact of occurrence, of all credible in-flight medical conditions. Fracture of the proximal femur is a traumatic injury that would likely result in loss of mission if it were to happen during spaceflight. The low gravity exposure causes decreases in bone mineral density which heightens the concern. Researchers at the NASA Glenn Research Center have quantified bone fracture probability during spaceflight with a probabilistic model. It was assumed that a pressurized extravehicular activity (EVA) suit would attenuate load during a fall, but no supporting data was available. The suit impact load attenuation study was performed to collect analogous data. METHODS: A pressurized EVA suit analog test bed was used to study how the offset, defined as the gap between the suit and the astronaut s body, impact load magnitude and suit operating pressure affects the attenuation of impact load. The attenuation data was incorporated into the probabilistic model of bone fracture as a function of these factors, replacing a load attenuation value based on commercial hip protectors. RESULTS: Load attenuation was more dependent on offset than on pressurization or load magnitude, especially at small offsets. Load attenuation factors for offsets between 0.1 - 1.5 cm were 0.69 +/- 0.15, 0.49 +/- 0.22 and 0.35 +/- 0.18 for mean impact forces of 4827, 6400 and 8467 N, respectively. Load attenuation factors for offsets of 2.8 - 5.3 cm were 0.93 +/- 0.2, 0.94 +/- 0.1 and 0.84 +/- 0.5, for the same mean impact forces. Reductions were observed in the 95th percentile confidence interval of the bone fracture probability predictions. CONCLUSIONS: The reduction in uncertainty and improved confidence in bone fracture predictions increased the fidelity and credibility of the fracture risk model and its benefit to mission design and operational decisions.
NASA Technical Reports Server (NTRS)
Adams, G. R.
1998-01-01
Adaptations in muscle mass stimulated by changes in muscle loading state entail alternations in the synthesis and degradation of myofiber proteins and the modulation of myonuclear number such that the ratio between the number of myonuclei and the size of the myofibers remains relatively constant. As depicted schematically in Figure 2.6, the literature regarding the role of IGF-in mediating muscle adaptation to alterations in loading state suggests the following conclusions: During periods of increased loading, myofibers upregulate the expression and secretion of IGF-I. Acting as an autocrine and/or paracrine growth factor, IGF-I stimulates myofiber anabolic processes. Acting as a paracrine growth factor, IGF-I also stimulates adjacent satellite cells to enter the cell cycle and proliferate. Continued myofiber production of IGF-I stimulates some satellite cells to differentiate and then fuse with myofibers, thus providing additional myonuclei in order to maintain or reestablish the myonucleus to myofiber size ratios of the enlarged myofibers.
NASA Technical Reports Server (NTRS)
Olson, R.E.; Allison, J.M.
1939-01-01
Present designs for large flying boats are characterized by high wing loading, high aspect ratio, and low parasite drag. The high wing loading results in the universal use of flaps for reducing the takeoff and landing speeds. These factors have an effect on takeoff performance and influence to a certain extent the design of the hull. An investigation was made of the influence of various factors and design parameters on the takeoff performance of a hypothetical large flying boat by means of takeoff calculations. The parameters varied in the calculations were size of hull (load coefficient), wing setting, trim, deflection of flap, wing loading, aspect ratio, and parasite drag. The takeoff times and distances were calculated to the stalling speeds and the performance above these speeds was studied separately to determine piloting technique for optimum takeoff. The advantage of quick deflection of the flap at high water speeds is shown.
NASA Astrophysics Data System (ADS)
Ramli, Nor Azlinda; Abdullah, Che Sobry; Nawi, Mohd Nasrun Mohd; Bahaudin, Ahmad Yusni
2016-08-01
This study addresses the factors that influence the adoption of load-bearing masonry (LBM) system. A case study of the load-bearing masonry (LBM) system adoption is conducted through an interview to explore the situation of the technology adoption in a construction company. The finding indicates the factors influence the adoption of LBM system for the construction company are: organizational resources, usefulness, less maintenance, reduce construction time and cost. From the findings, these factors consistent with previous literature. Furthermore, the performance of the company was measured by looking into the financial and non-financial aspects. The LBM system brings good performance as it increased the profits of the company, a good quality of product and attracts more demand from customers. Thus, these factors should be considered for the other companies that are interested in implementing the LBM system in their projects.
Static load simulation of steering knuckle for a formula student race car
NASA Astrophysics Data System (ADS)
Saputro, Bagus Aulia; Ubaidillah, Triono, Dicky Agus; Pratama, Dzaky Roja; Cahyono, Sukmaji Indro; Imaduddin, Fitrian
2018-02-01
This research aims to determine the stress distribution which occurs on the steering knuckle and to define its safety factor number. Steering knuckle is the most critical part of a car's steering system. Steering knuckle supports the tie rod, brake caliper, and the wheels to provide stability. Steering knuckle withstands the load which given on the front wheels and functions as the wheel's axis. Balljoint and king support the rotation of the suspension arm. When the car is in idle position, knuckle hold the weight of the car, it gets braking force when it's braking and cornering. Knuckle is designed to have the strength that could withstand load and to have a good safety factor value. Knuckle is designed using Fusion software then simulated using Fusion simulation software with a static load, moment braking force, and cornering force as the loads in this simulation. The simulation works in ideal condition. The result of this simulation is satisfying. This simulation produces a maximum displacement of 0.01281mm, the maximum shear stress is 3.707 MPa on the stub hole, and the safety factor is 5.24. The material used for this product is mild steel AISI 1018.
Chen, Fang Fang
2008-11-01
It is a common practice to export instruments developed in one culture to another. Little is known about the consequences of making inappropriate comparisons in cross-cultural research. Several studies were conducted to fill in this gap. Study 1 examined the impact of lacking factor loading invariance on regression slope comparisons. When factor loadings of a predictor are higher in the reference group (e.g., United States), for which the scale was developed, than in the focal group (e.g., China), into which the scale was imported, the predictive relationship (e.g., self-esteem predicting life satisfaction) is artificially stronger in the reference group but weaker in the focal group, creating a bogus interaction effect of predictor by group (e.g., self-esteem by culture); the opposite pattern is found when the reference group has higher loadings in an outcome variable. Studies 2 and 3 examined the impact of lacking loading and intercept (i.e., point of origin) invariance on factor means, respectively. When the reference group has higher loadings or intercepts, the mean is overestimated in that group but underestimated in the focal group, resulting in a pseudo group difference. (c) 2008 APA, all rights reserved.
Blanco, Carlos; García-Anaya, María; Wall, Melanie; de los Cobos, José Carlos Pérez; Swierad, Ewelina; Wang, Shuai; Petry, Nancy M.
2015-01-01
Objective Pathological gambling (PG) is now aligned with substance use disorders in the DSM-5 as the first officially recognized behavioral addiction. There is growing interest in examining obesity as an addictive disorder as well. The goal of this study was to investigate whether epidemiological data provide support for the consideration of PG and obesity as addictive disorders. Method Factor analysis of data from a large, nationally representative sample of US adults (N=43,093), using nicotine dependence, alcohol dependence, drug dependence, PG and obesity as indicators. It was hypothesized that nicotine dependence, alcohol dependence and drug use dependence would load on a single factor. It was further hypothesized that if PG and obesity were addictive disorders, they would load on the same factor as substance use disorders, whereas failure to load on the addictive factor would not support their conceptualization as addictive disorders. Results A model with one factor including nicotine dependence, alcohol dependence, drug dependence and PG, but not obesity, provided a very good fit to the data, as indicated by CFI=0.99, TLI=0.99 and RMSEA=.01 and loadings of all indicators >0.4. Conclusion Data from this study support the inclusion of PG in a latent factor with substance use disorders but do not lend support to the consideration of obesity, as defined by BMI, as an addictive disorder. Future research should investigate whether certain subtypes of obesity are best conceptualized as addictive disorders and the shared biological and environmental factors that account for the common and specific features of addictive disorders. PMID:25769392
Phillip Harte; Marcel Belaval; Andrea Traviglia
2016-01-01
The lag time between groundwater recharge and discharge in a watershed and the potential groundwater load to streams is an important factor in forecasting responses to future land use practices. We call this concept managing the âspace-time-load continuum.â Itâs understood that in any given watershed, the response function (the load at any given time) will differ for...
Fatigue flaw growth behavior in stiffened and unstiffened panels loaded in biaxial tension
NASA Technical Reports Server (NTRS)
Beck, E. J.
1973-01-01
The effect was investigated of biaxial loading on the flaw growth rate of 2219-T87 aluminum alloy that would be typical of Space Shuttle cryogenic tankage design. The stress distribution and stress concentration factors for several integrally stiffened panels under various loading conditions were obtained. The flaw growth behavior of both stiffened and unstiffened panels under biaxial loading conditions was determined. The effect of a complex stress state was studied by introducing flaws in fillet areas of biaxially loaded stiffened panels.
Sewell, Justin L; Boscardin, Christy K; Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S
2017-11-01
Cognitive load theory, focusing on limits of the working memory, is relevant to medical education; however, factors associated with cognitive load during procedural skills training are not well characterized. The authors sought to determine how features of learners, patients/tasks, settings, and supervisors were associated with three types of cognitive load among learners performing a specific procedure, colonoscopy, to identify implications for procedural teaching. Data were collected through an electronically administered survey sent to 1,061 U.S. gastroenterology fellows during the 2014-2015 academic year; 477 (45.0%) participated. Participants completed the survey immediately following a colonoscopy. Using multivariable linear regression analyses, the authors identified sets of features associated with intrinsic, extraneous, and germane loads. Features associated with intrinsic load included learners (prior experience and year in training negatively associated, fatigue positively associated) and patient/tasks (procedural complexity positively associated, better patient tolerance negatively associated). Features associated with extraneous load included learners (fatigue positively associated), setting (queue order positively associated), and supervisors (supervisor engagement and confidence negatively associated). Only one feature, supervisor engagement, was (positively) associated with germane load. These data support practical recommendations for teaching procedural skills through the lens of cognitive load theory. To optimize intrinsic load, level of experience and competence of learners should be balanced with procedural complexity; part-task approaches and scaffolding may be beneficial. To reduce extraneous load, teachers should remain engaged, and factors within the procedural setting that may interfere with learning should be minimized. To optimize germane load, teachers should remain engaged.
Unpacking the Complexity of Patient Handoffs Through the Lens of Cognitive Load Theory.
Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S; Irby, David M
2016-01-01
The transfer of a patient from one clinician to another is a high-risk event. Errors are common and lead to patient harm. More effective methods for learning how to give and receive sign-out is an important public health priority. Performing a handoff is a complex task. Trainees must simultaneously apply and integrate clinical, communication, and systems skills into one time-limited and highly constrained activity. The task demands can easily exceed the information-processing capacity of the trainee, resulting in impaired learning and performance. Appreciating the limits of working memory can help identify the challenges that instructional techniques and research must then address. Cognitive load theory (CLT) identifies three types of load that impact working memory: intrinsic (task-essential), extraneous (not essential to task), and germane (learning related). The authors generated a list of factors that affect a trainee's learning and performance of a handoff based on CLT. The list was revised based on feedback from experts in medical education and in handoffs. By consensus, the authors associated each factor with the type of cognitive load it primarily effects. The authors used this analysis to build a conceptual model of handoffs through the lens of CLT. The resulting conceptual model unpacks the complexity of handoffs and identifies testable hypotheses for educational research and instructional design. The model identifies features of a handoff that drive extraneous, intrinsic, and germane load for both the sender and the receiver. The model highlights the importance of reducing extraneous load, matching intrinsic load to the developmental stage of the learner and optimizing germane load. Specific CLT-informed instructional techniques for handoffs are explored. Intrinsic and germane load are especially important to address and include factors such as knowledge of the learner, number of patients, time constraints, clinical uncertainties, overall patient/panel complexity, interacting comorbidities or therapeutics, experience or specialty gradients between the sender and receiver, the maturity of the evidence base for the patient's disease, and the use of metacognitive techniques. Research that identifies which cognitive load factors most significantly affect the learning and performance of handoffs can lead to novel, contextually adapted instructional techniques and handoff protocols. The application of CLT to handoffs may also help with the further development of CLT as a learning theory.
Internal consistency and validity of a new physical workload questionnaire
Bot, S; Terwee, C; van der Windt, D A W M; Feleus, A; Bierma-Zeinstra, S; Knol, D; Bouter, L; Dekker, J
2004-01-01
Aims: To examine the dimensionality, internal consistency, and construct validity of a new physical workload questionnaire in employees with musculoskeletal complaints. Methods: Factor analysis was applied to the responses in three study populations with musculoskeletal disorders (n = 406, 300, and 557) on 26 items related to physical workload. The internal consistency of the resulting subscales was examined. It was hypothesised that physical workload would vary among different occupational groups. The occupations of all subjects were classified into four groups on the basis of expected workload (heavy physical load; long lasting postures and repetitive movements; both; no physical load). Construct validity of the subscales created was tested by comparing the subscale scores among these occupational groups. Results: The pattern of the factor loadings of items was almost identical for the three study populations. Two interpretable factors were found: items related to heavy physical workload loaded highly on the first factor, and items related to static postures or repetitive work loaded highly on the second factor. The first constructed subscale "heavy physical work" had a Cronbach's α of 0.92 to 0.93 and the second subscale "long lasting postures and repetitive movements", of 0.86 to 0.87. Six of eight hypotheses regarding the construct validity of the subscales were confirmed. Conclusions: The results support the internal structure, internal consistency, and validity of the new physical workload questionnaire. Testing this questionnaire in non-symptomatic employees and comparing its performance with objective assessments of physical workload are important next steps in the validation process. PMID:15550603
Use of herd information for predicting Salmonella status in pig herds.
Baptista, F M; Alban, L; Nielsen, L R; Domingos, I; Pomba, C; Almeida, V
2010-11-01
Salmonella surveillance-and-control programs in pigs are highly resource demanding, so alternative cost-effective approaches are desirable. The aim of this study was to develop and evaluate a tool for predicting the Salmonella test status in pig herds based on herd information collected from 108 industrial farrow-to-finish pig herds in Portugal. A questionnaire including known risk factors for Salmonella was used. A factor analysis model was developed to identify relevant factors that were then tested for association with Salmonella status. Three factors were identified and labelled: general biosecurity (factor 1), herd size (factor 2) and sanitary gap implementation (factor 3). Based on the loadings in factor 1 and factor 3, herds were classified according to their biosecurity practices. In total, 59% of the herds had a good level of biosecurity (interpreted as a loading below zero in factor 1) and 37% of the farms had good biosecurity and implemented sanitary gap (loading below zero in factor 1 and loading above zero in factor 3). This implied that they, among other things, implemented preventive measures for visitors and workers entering the herd, controlled biological vectors, had hygiene procedures in place, water quality assessment, and sanitary gap in the fattening and growing sections. In total, 50 herds were tested for Salmonella. Logistic regression analysis showed that factor 1 was significantly associated with Salmonella test status (P = 0.04). Herds with poor biosecurity had a higher probability of testing Salmonella positive compared with herds with good biosecurity. This study shows the potential for using herd information to classify herds according to their Salmonella status in the absence of good testing options. The method might be used as a potentially cost-effective tool for future development of risk-based approaches to surveillance, targeting interventions to high-risk herds or differentiating sampling strategies in herds with different levels of infection. © 2010 Blackwell Verlag GmbH.
Factors that affect the fatigue strength of power transmission shafting
NASA Technical Reports Server (NTRS)
Loewenthal, S. H.
1984-01-01
A long standing objective in the design of power transmission shafting is to eliminate excess shaft material without compromising operational reliability. A shaft design method is presented which accounts for variable amplitude loading histories and their influence on limited life designs. The effects of combined bending and torsional loading are considered along with a number of application factors known to influence the fatigue strength of shafting materials. Among the factors examined are surface condition, size, stress concentration, residual stress and corrosion fatigue.
Fine particle and organic vapor emissions from staged tests of an in-use aircraft engine
NASA Astrophysics Data System (ADS)
Presto, Albert A.; Nguyen, Ngoc T.; Ranjan, Manish; Reeder, Aaron J.; Lipsky, Eric M.; Hennigan, Christopher J.; Miracolo, Marissa A.; Riemer, Daniel D.; Robinson, Allen L.
2011-07-01
Staged tests were conducted to measure the particle and vapor emissions from a CFM56-2B1 gas-turbine engine mounted on a KC-135T Stratotanker airframe at different engine loads. Exhaust was sampled using a rake inlet installed 1-m downstream of the engine exit plane of a parked and chocked aircraft and a dilution sampler and portable smog chamber were used to investigate the particulate matter (PM) emissions. Total fine PM mass emissions were highest at low (4%) and high (85%) load and lower at intermediate loads (7% and 30%). PM mass emissions at 4% load are dominated by organics, while at 85% load elemental carbon is dominant. Quantifying the primary organic aerosol (POA) emissions is complicated by substantial filter sampling artifacts. Partitioning experiments reveal that the majority of the POA is semivolatile; for example, the POA emission factor changed by a factor of two when the background organic aerosol concentration was increased from 0.7 to 4 μg m -3. Therefore, one cannot define a single non-volatile PM emission factor for aircraft exhaust. The gas- and particle-phase organic emissions were comprehensively characterized by analyzing canister, sorbent and filter samples with gas-chromatography/mass-spectrometry. Vapor-phase organic emissions are highest at 4% load and decrease with increasing load. Low-volatility organics (less volatile than a C 12n-alkane) contributed 10-20% of the total organic emissions. The low-volatility organic emissions contain signatures of unburned fuel and aircraft lubricating oil but are dominated by an unresolved complex mixture (UCM) of presumably branched and cyclic alkanes. Emissions at all loads contain more low-volatility organic vapors than POA; thus secondary organic aerosol formation in the aging plume will likely exceed POA emissions.
Reynolds, Matthew R
2013-03-01
The linear loadings of intelligence test composite scores on a general factor (g) have been investigated recently in factor analytic studies. Spearman's law of diminishing returns (SLODR), however, implies that the g loadings of test scores likely decrease in magnitude as g increases, or they are nonlinear. The purpose of this study was to (a) investigate whether the g loadings of composite scores from the Differential Ability Scales (2nd ed.) (DAS-II, C. D. Elliott, 2007a, Differential Ability Scales (2nd ed.). San Antonio, TX: Pearson) were nonlinear and (b) if they were nonlinear, to compare them with linear g loadings to demonstrate how SLODR alters the interpretation of these loadings. Linear and nonlinear confirmatory factor analysis (CFA) models were used to model Nonverbal Reasoning, Verbal Ability, Visual Spatial Ability, Working Memory, and Processing Speed composite scores in four age groups (5-6, 7-8, 9-13, and 14-17) from the DAS-II norming sample. The nonlinear CFA models provided better fit to the data than did the linear models. In support of SLODR, estimates obtained from the nonlinear CFAs indicated that g loadings decreased as g level increased. The nonlinear portion for the nonverbal reasoning loading, however, was not statistically significant across the age groups. Knowledge of general ability level informs composite score interpretation because g is less likely to produce differences, or is measured less, in those scores at higher g levels. One implication is that it may be more important to examine the pattern of specific abilities at higher general ability levels. PsycINFO Database Record (c) 2013 APA, all rights reserved.
The Latent Structure of Spatial Skills and Mathematics: A Replication of the Two-Factor Model
ERIC Educational Resources Information Center
Mix, Kelly S.; Levine, Susan C.; Cheng, Yi-Lang; Young, Christopher J.; Hambrick, David Z.; Konstantopoulos, Spyros
2017-01-01
In a previous study, Mix et al. (2016) reported that spatial skill and mathematics were composed of 2 highly correlated, domain-specific factors, with a few cross-domain loadings. The overall structure was consistent across grade (kindergarten, 3rd grade, 6th grade), but the cross-domain loadings varied with age. The present study sought to…
A. C. Gellis; NO-VALUE
2013-01-01
The significant characteristics controlling the variability in storm-generated suspended-sediment loads and concentrations were analyzed for four basins of differing land use (forest, pasture, cropland, and urbanizing) in humid-tropical Puerto Rico. Statistical analysis involved stepwise regression on factor scores. The explanatory variables were attributes of flow,...
ERIC Educational Resources Information Center
Maynard, Jennifer L.; Floyd, Randy G.; Acklie, Teresa J.; Houston, Lawrence, III
2011-01-01
The purpose of this study was to investigate the "g" loadings and specific effects of the core and diagnostic composite scores from the Differential Abilities Scales, Second Edition (DAS-II; Elliott, 2007a). Scores from a subset of the DAS-II standardization sample for ages 3:6 to 17:11 were submitted to principal factor analysis. Four…
Behavior of Fatigue Crack Tip Opening in Air and Corrosive Atmosphere
NASA Astrophysics Data System (ADS)
Hayashi, Morihito; Toeda, Kazunori
In the study, a formula for predicting fatigue crack tip opening displacement is deduced firstly. And then, due to comparing actual crack growth rate with the deduced formula, the crack tip configuration factor is defined to figure out the crack tip opening configuration that is useful to clarify the behavior of fatigue crack tip formation apparently. Applying the concept, the crack growth of 7/3 brass and 6/4 brass is predicted from the formula, by replacing material properties such as plastic flow resistance, Young modulus, the Poisson ratio, and fatigue toughness, and fatigue test conditions such as the stress intensity factor range, the load ratio, and cycle frequency. Furthermore, the theoretically expected results are verified with the fatigue tests which were carried out on CT specimens under different load conditions of load ratio, cycle frequency, and cyclic peak load, in different environments of air or corrosive ammonia atmosphere, for various brasses. And by comparing and discussing the calculated crack growth rate with attained experimental results, the apparent configuration factor at the crack tip is determined. And through the attained factor which changes along with crack growth, the behaviors of fatigue crack tip formation under different test conditions have been found out.
Schürmann, Tim; Beckerle, Philipp; Preller, Julia; Vogt, Joachim; Christ, Oliver
2016-12-19
In product development for lower limb prosthetic devices, a set of special criteria needs to be met. Prosthetic devices have a direct impact on the rehabilitation process after an amputation with both perceived technological and psychological aspects playing an important role. However, available psychometric questionnaires fail to consider the important links between these two dimensions. In this article a probabilistic latent trait model is proposed with seven technical and psychological factors which measure satisfaction with the prosthesis. The results of a first study are used to determine the basic parameters of the statistical model. These distributions represent hypotheses about factor loadings between manifest items and latent factors of the proposed psychometric questionnaire. A study was conducted and analyzed to form hypotheses for the prior distributions of the questionnaire's measurement model. An expert agreement study conducted on 22 experts was used to determine the prior distribution of item-factor loadings in the model. Model parameters that had to be specified as part of the measurement model were informed prior distributions on the item-factor loadings. For the current 70 items in the questionnaire, each factor loading was set to represent the certainty with which experts had assigned the items to their respective factors. Considering only the measurement model and not the structural model of the questionnaire, 70 out of 217 informed prior distributions on parameters were set. The use of preliminary studies to set prior distributions in latent trait models, while being a relatively new approach in psychological research, provides helpful information towards the design of a seven factor questionnaire that means to identify relations between technical and psychological factors in prosthetic product design and rehabilitation medicine.
Kausto, Johanna; Miranda, Helena; Pehkonen, Irmeli; Heliövaara, Markku; Viikari-Juntura, Eira; Solovieva, Svetlana
2011-10-01
There is growing evidence that physical and psychosocial exposures at work increase the risk of musculoskeletal disorders. The aim of this study was to describe the distribution and co-occurrence of these risk factors in the working population. We used data from the Health 2000 survey carried out in Finland in 2000-2001. The sample of our study consisted of 2,491 men and 2,613 women who had been actively working during the year preceding the survey. Logistic regression and exploratory factor analysis were used to analyze the co-occurrence of the work-related risk factors. Exposure to high physical work load and several co-occurring work load factors was more prevalent among men than women. In women, as opposed to men, the highest exposure to most physical work load factors was found in their later work life. Gender and age showed weak associations with psychosocial work load factors. Low socioeconomic position, in both genders, was related to an increased risk of being exposed to several co-occurring physical or psychosocial factors. Physical exposures most frequently co-occurred with high job demands and low job control in men. Among women, physical exposures were found to co-occur with high job demands, low job control and job insecurity. This study provides novel information on the occupational exposures in general working population. It appears that co-occurrence of physical and psychosocial exposures should be considered in research and prevention of musculoskeletal disorders. In addition, a broader set of occupational factors, e.g., work organization, are suggested to be included in future studies to cover all the relevant determinants.
14 CFR 23.787 - Baggage and cargo compartments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and... critical load distributions at the appropriate maximum load factors corresponding to the flight and ground...
Short-term load forecasting of power system
NASA Astrophysics Data System (ADS)
Xu, Xiaobin
2017-05-01
In order to ensure the scientific nature of optimization about power system, it is necessary to improve the load forecasting accuracy. Power system load forecasting is based on accurate statistical data and survey data, starting from the history and current situation of electricity consumption, with a scientific method to predict the future development trend of power load and change the law of science. Short-term load forecasting is the basis of power system operation and analysis, which is of great significance to unit combination, economic dispatch and safety check. Therefore, the load forecasting of the power system is explained in detail in this paper. First, we use the data from 2012 to 2014 to establish the partial least squares model to regression analysis the relationship between daily maximum load, daily minimum load, daily average load and each meteorological factor, and select the highest peak by observing the regression coefficient histogram Day maximum temperature, daily minimum temperature and daily average temperature as the meteorological factors to improve the accuracy of load forecasting indicators. Secondly, in the case of uncertain climate impact, we use the time series model to predict the load data for 2015, respectively, the 2009-2014 load data were sorted out, through the previous six years of the data to forecast the data for this time in 2015. The criterion for the accuracy of the prediction is the average of the standard deviations for the prediction results and average load for the previous six years. Finally, considering the climate effect, we use the BP neural network model to predict the data in 2015, and optimize the forecast results on the basis of the time series model.
Duffy, Frank H; Als, Heidelise
2012-06-26
The autism rate has recently increased to 1 in 100 children. Genetic studies demonstrate poorly understood complexity. Environmental factors apparently also play a role. Magnetic resonance imaging (MRI) studies demonstrate increased brain sizes and altered connectivity. Electroencephalogram (EEG) coherence studies confirm connectivity changes. However, genetic-, MRI- and/or EEG-based diagnostic tests are not yet available. The varied study results likely reflect methodological and population differences, small samples and, for EEG, lack of attention to group-specific artifact. Of the 1,304 subjects who participated in this study, with ages ranging from 1 to 18 years old and assessed with comparable EEG studies, 463 children were diagnosed with autism spectrum disorder (ASD); 571 children were neuro-typical controls (C). After artifact management, principal components analysis (PCA) identified EEG spectral coherence factors with corresponding loading patterns. The 2- to 12-year-old subsample consisted of 430 ASD- and 554 C-group subjects (n = 984). Discriminant function analysis (DFA) determined the spectral coherence factors' discrimination success for the two groups. Loading patterns on the DFA-selected coherence factors described ASD-specific coherence differences when compared to controls. Total sample PCA of coherence data identified 40 factors which explained 50.8% of the total population variance. For the 2- to 12-year-olds, the 40 factors showed highly significant group differences (P < 0.0001). Ten randomly generated split half replications demonstrated high-average classification success (C, 88.5%; ASD, 86.0%). Still higher success was obtained in the more restricted age sub-samples using the jackknifing technique: 2- to 4-year-olds (C, 90.6%; ASD, 98.1%); 4- to 6-year-olds (C, 90.9%; ASD 99.1%); and 6- to 12-year-olds (C, 98.7%; ASD, 93.9%). Coherence loadings demonstrated reduced short-distance and reduced, as well as increased, long-distance coherences for the ASD-groups, when compared to the controls. Average spectral loading per factor was wide (10.1 Hz). Classification success suggests a stable coherence loading pattern that differentiates ASD- from C-group subjects. This might constitute an EEG coherence-based phenotype of childhood autism. The predominantly reduced short-distance coherences may indicate poor local network function. The increased long-distance coherences may represent compensatory processes or reduced neural pruning. The wide average spectral range of factor loadings may suggest over-damped neural networks.
Creation of an Aeronautical Capstone Design Project Program at Ohio State University
2014-12-08
Equation 12 below. As Figure 35 shows, a single adhesively bonded lap joint is considered. The epoxy only sees a load in the axial direction. In...lap joint [1] = = ( ) 12 =stress distribution factor = applied load in the axial direction ...Figure 11. The joints are designed to handle the bending loads of horizontal, vertical and angled deployment and are designed to directly load the carbon
Li, Guicai; Xiao, Qinzhi; Zhang, Luzhong; Zhao, Yahong; Yang, Yumin
2017-09-01
Artificial chitosan scaffolds have been widely investigated for peripheral nerve regeneration. However, the effect was not as good as that of autologous grafts and therefore could not meet the clinical requirement. In the present study, the nerve growth factor (NGF) loaded heparin/chitosan scaffolds were fabricated via electrostatic interaction for further improving nerve regeneration. The physicochemical properties including morphology, wettability and composition were measured. The heparin immobilization, NGF loading and release were quantitatively and qualitatively characterized, respectively. The effect of NGF loaded heparin/chitosan scaffolds on nerve regeneration was evaluated by Schwann cells culture for different periods. The results showed that the heparin immobilization and NGF loading did not cause the change of bulk properties of chitosan scaffolds except for morphology and wettability. The pre-immobilization of heparin in chitosan scaffolds could enhance the stability of subsequently loaded NGF. The NGF loaded heparin/chitosan scaffolds could obviously improve the attachment and proliferation of Schwann cells in vitro. More importantly, the NGF loaded heparin/chitosan scaffolds could effectively promote the morphology development of Schwann cells. The study may provide a useful experimental basis to design and develop artificial implants for peripheral nerve regeneration and other tissue regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.
Baharifar, Hadi; Amani, Amir
2017-01-01
When designing nanoparticles for drug delivery, many variables such as size, loading efficiency, and cytotoxicity should be considered. Usually, smaller particles are preferred in drug delivery because of longer blood circulation time and their ability to escape from immune system, whereas smaller nanoparticles often show increased toxicity. Determination of parameters which affect size of particles and factors such as loading efficiency and cytotoxicity could be very helpful in designing drug delivery systems. In this work, albumin (as a protein drug model)-loaded chitosan nanoparticles were prepared by polyelectrolyte complexation method. Simultaneously, effects of 4 independent variables including chitosan and albumin concentrations, pH, and reaction time were determined on 3 dependent variables (i.e., size, loading efficiency, and cytotoxicity) by artificial neural networks. Results showed that concentrations of initial materials are the most important factors which may affect the dependent variables. A drop in the concentrations decreases the size directly, but they simultaneously decrease loading efficiency and increase cytotoxicity. Therefore, an optimization of the independent variables is required to obtain the most useful preparation. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Flying Lessons: Learning from Ryanair's Cost Reduction Culture
NASA Technical Reports Server (NTRS)
Lawton, Thomas C.
2000-01-01
Through radically improving the value equation for airline customers, Ryanair has served to shake-up established norms and practices in European aviation. Underpinning its price leadership and market success is a vigorous and relentless cost reduction ethos and resultant low break-even load factor. Ryanair has lowered European airline cost structures considerably, shattering existing cost floors. Few competitors are able to follow, either because they do not know how or they are unable due to social settlement obligations or service commitments. At the same time, the company has maintained high average load factors on its flights. Taken in conjunction with its low break-even load factor, this results in consistently high overall profit margins. On this basis, Ryanair is likely to remain a significant competitor and increase its market presence and success across Europe.
Whiting, Terry L; Drain, Mairead E; Rasali, Drona P
2007-02-01
This observational study was conducted to identify the cause of death and load level factors associated with mortality in 1 090 733 Manitoba broiler chickens transported to slaughter in spring and early summer. Death loss in transit was 0.346% and accounted for 19% of the total carcass condemnation. The death loss pattern was clearly bimodal, with a low death loss in 180 of 198 shipments. Cumulative death loss during the growing phase of production was consistently associated with increased transport mortalities in load level models and when comparing high death loss with low death loss truckloads. High ambient temperature at the time of slaughter and loading density of the truck were the major factors associated with exceptional death loss.
Psychometric evaluation of the Nurse Practitioner Satisfaction Survey (NPSS).
Agosta, Lucie J
2009-01-01
The purpose of this study was to identify and define underlying latent constructs within the concept of patient satisfaction with nurse practitioner delivered primary health care. The Nurse Practitioner Satisfaction Survey (NPSS), a 28-item, Likert-type, researcher developed instrument was completed by 300 clients presenting for primary health care visits in a hospital outpatient clinic. Factor analysis with promax rotation resulted in a three factor model explaining 70.77% of the variance. Eighteen items loaded on general satisfaction. Six items loaded on communication, and four items loaded on accessibility and convenience. Cronbach's alpha internal consistency reliability coefficients were .98, .83, and .76 for the three factors, respectively. The NPSS was found to be reliable and valid for measuring patient satisfaction with nurse practitioner delivered primary health care services.
[The risk of neoplastic processes transformation in cervix uteri].
Kiseleva, V I; Krikunova, L I; Mkrtchian, L S; Liubina, L V; Beziaeva, G P; Panarina, L V; Zamuliaeva, I A
2014-01-01
There was performed a comparative analysis of quantitative load and physical status of human papillomavirus (HPV) type 16 in groups of patients with cervical intraepithelial neoplasia (CIN)--25 people and cervical cancer (CC)--85 people. According to the analysis there were selected criteria appropriate to a combination of adverse factors that characterized HPV- infection and at the same time estimated both quantitative load and physical status of the virus: high viral load (> 6,5 lg copies of HPV DNA per 100000 cells) in episomal form or low load (< 6,5 lg copies of HPV DNA per 100000 cells) in integrated form of the virus. According to calculations a relative chance of appearing of CC in CIN patients with unfavorable combination of factors was 7,5 times higher than in other patients.
Object-Based Attention Overrides Perceptual Load to Modulate Visual Distraction
ERIC Educational Resources Information Center
Cosman, Joshua D.; Vecera, Shaun P.
2012-01-01
The ability to ignore task-irrelevant information and overcome distraction is central to our ability to efficiently carry out a number of tasks. One factor shown to strongly influence distraction is the perceptual load of the task being performed; as the perceptual load of task-relevant information processing increases, the likelihood that…
DOT National Transportation Integrated Search
2011-07-01
Current roadway pavement design practices follow the standards set by the American Society of State : Highway and Transportation Officials (AASHTO), which require the use of an equivalent single axle load : (ESAL-18 kip single axle load) for design t...
Jiang, Z; Dou, Z; Yan, Z H; Song, W L; Chen, Y; Ren, X L; Chen, J; Cao, W; Xu, J; Wu, Z Y
2017-09-10
Objective: To analyze the effect of missing data in population based viral load (PVL) survey in HIV infected men who have sex with men (MSM) sampled in 16 cities in China. Methods: The database of 3 virus load sampling survey conducted consecutively in HIV infected MSM population in 16 large cities (Beijing, Shanghai, Nanjing, Hangzhou, Wuhan, Chongqing, Kunming, Xi'an, Guangzhou, Shenzhen, Nanning, Urumuqi, Harbin, Changchun, Chengdu and Tianjin) during 2013-2015 was used. SPSS 17.0 software was used to describe distribution of the missing data and analyze associated factors. Results: A total of 12 150 HIV infected MSM were randomly selected for the surveys, in whom, 9 141 (75.2 % ) received virus load tests, while 3 009 (24.8 % ) received no virus load tests, whose virus load data missed. The virus load data missing rates in MSM with or without access to antiretroviral therapy (ART) were 11.5 % (765/6 675) and 39.4 % (2 060/5 223) respectively, and the virus load data missing rates were 21.9 % (1 866/8 523) and 28.4 % (959/3 374), respectively, in local residents and non-local residents (migrants). Conclusions: The analysis indicated that the data missing occurred in the virus load survey in HIV infected MSM population. ART status and census registering status were the main influencing factors. Data missing could influence the accurate evaluation of community viral load (CVL) and population viral load(PVL) levels in HIV infected MSM in China.
Miller, Woutrina A; Lewis, David J; Lennox, Michael; Pereira, Maria G C; Tate, Kenneth W; Conrad, Patricia A; Atwill, Edward R
2007-11-01
Climatic factors and on-farm management practices were evaluated for their association with the concentrations (cyst/liter) and instantaneous loads (cysts/second) of Giardia duodenalis in storm-based runoff from dairy lots and other high-cattle-use areas on five coastal California farms over two storm seasons. Direct fluorescent antibody analysis was used to quantitate cysts in 350 storm runoff samples. G. duodenalis was detected on all five dairy farms, with fluxes of 1 to 14,000 cysts/liter observed in 16% of samples. Cysts were detected in 41% of runoff samples collected near cattle less than 2 months old, compared to 10% of runoff samples collected near cattle over 6 months old. Furthermore, the concentrations and instantaneous loads of cysts were > or =65 and > or =79 times greater, respectively, in runoff from sites housing young calves than in sites housing other age classes of animals. Factors associated with environmental loading of G. duodenalis included cattle age, cattle stocking number, and precipitation but not lot area, land slope, or cattle density. Vegetated buffer strips were found to significantly reduce waterborne cysts in storm runoff: each additional meter of vegetated buffer placed below high-cattle-use areas was associated with reductions in the concentration and instantaneous load of cysts by factors of 0.86 and 0.79 (-0.07 and -0.10 log(10)/m), respectively. Straw mulch, seed application, scraping of manure, and cattle exclusion did not significantly affect the concentration or load of G. duodenalis cysts. The study findings suggest that vegetated buffer strips, especially when placed near dairy calf areas, should help reduce the environmental loading of these fecal protozoa discharging from dairy farms.
Effect of Combined Loading Due to Bending and Internal Pressure on Pipe Flaw Evaluation Criteria
NASA Astrophysics Data System (ADS)
Miura, Naoki; Sakai, Shinsuke
Considering a rule for the rationalization of maintenance of Light Water Reactor piping, reliable flaw evaluation criteria are essential for determining how a detected flaw will be detrimental to continuous plant operation. Ductile fracture is one of the dominant failure modes that must be considered for carbon steel piping and can be analyzed by elastic-plastic fracture mechanics. Some analytical efforts have provided various flaw evaluation criteria using load correction factors, such as the Z-factors in the JSME codes on fitness-for-service for nuclear power plants and the section XI of the ASME boiler and pressure vessel code. The present Z-factors were conventionally determined, taking conservativity and simplicity into account; however, the effect of internal pressure, which is an important factor under actual plant conditions, was not adequately considered. Recently, a J-estimation scheme, LBB.ENGC for the ductile fracture analysis of circumferentially through-wall-cracked pipes subjected to combined loading was developed for more accurate prediction under more realistic conditions. This method explicitly incorporates the contributions of both bending and tension due to internal pressure by means of a scheme that is compatible with an arbitrary combined-loading history. In this study, the effect of internal pressure on the flaw evaluation criteria was investigated using the new J-estimation scheme. The Z-factor obtained in this study was compared with the presently used Z-factors, and the predictability of the current flaw evaluation criteria was quantitatively evaluated in consideration of the internal pressure.
Preliminary Study of Applied Load Factors in Bumpy Air
NASA Technical Reports Server (NTRS)
Rhode, Richard V; Lundquist, Eugene E
1931-01-01
Theoretical relations involved in the study are reviewed to furnish a basis upon which experimental data can be properly analyzed. The structure of the atmosphere in relation to the load-factor problem is briefly discussed, and the acceleration data obtained on a number of flights with various airplanes are presented and analyzed to the extent that the results are applicable to n=any airplane.
Soldier Performance as a Function of Stress and Load: A Review
1990-01-01
1985) increasing load obstacle course decreased weight performance Ikai & Steinhaus shouting forearm flex strength increased (1961) gun shot increased...performance. Capacity represents relatively fil1 ed physiological limits of behavior, while performance is a function of psychological factors (Ikai & Steinhaus ...3), 513-524. Ikai, M., & Steinhaus , A. H. (1961). Some factors modifying the expression of human strength. Journal of ADnlied Physiology, 15, 157-163
Reliability-based criteria for load and resistance factor design code for wood bridges
Chris Eamon; Andrzej S. Nowak; Michael A. Ritter; Joe Murphy
2000-01-01
Recently AASHTO adopted a load and resistance factor design code for highway bridges. The new code provides a rational basis for the design of steel and concrete structures. However, the calibration was not done for wood bridges. Therefore, there is a need to fill this gap. The development of statistical models for wood bridge structures is discussed. Recent test...
Comparison of Deterministic and Probabilistic Radial Distribution Systems Load Flow
NASA Astrophysics Data System (ADS)
Gupta, Atma Ram; Kumar, Ashwani
2017-12-01
Distribution system network today is facing the challenge of meeting increased load demands from the industrial, commercial and residential sectors. The pattern of load is highly dependent on consumer behavior and temporal factors such as season of the year, day of the week or time of the day. For deterministic radial distribution load flow studies load is taken as constant. But, load varies continually with a high degree of uncertainty. So, there is a need to model probable realistic load. Monte-Carlo Simulation is used to model the probable realistic load by generating random values of active and reactive power load from the mean and standard deviation of the load and for solving a Deterministic Radial Load Flow with these values. The probabilistic solution is reconstructed from deterministic data obtained for each simulation. The main contribution of the work is: Finding impact of probable realistic ZIP load modeling on balanced radial distribution load flow. Finding impact of probable realistic ZIP load modeling on unbalanced radial distribution load flow. Compare the voltage profile and losses with probable realistic ZIP load modeling for balanced and unbalanced radial distribution load flow.
Emmelin, Maria; Weinehall, Lars; Stenlund, Hans; Wall, Stig; Dahlgren, Lars
2007-01-01
Background Public health interventions are directed towards social systems and it is difficult to foresee all consequences. While targeted outcomes may be positively influenced, interventions may at worst be counterproductive. To include self-reported health in an evaluation is one way of addressing possible side-effects. This study is based on a 10 year follow-up of a cardiovascular community intervention programme in northern Sweden. Methods Both quantitative and qualitative approaches were used to address the interaction between changes in self-rated health and risk factor load. Qualitative interviews contributed to an analysis of how the outcome was influenced by health related norms and attitudes. Results Most people maintained a low risk factor load and a positive perception of health. However, more people improved than deteriorated their situation regarding both perceived health and risk factor load. "Ideal types" of attitude sets towards the programme, generated from the interviews, helped to interpret an observed polarisation for men and the lower educated. Conclusion Our observation of a socially and gender differentiated intervention effect suggests a need to test new intervention strategies. Future community interventions may benefit from targeting more directly those who in combination with high risk factor load perceive their health as bad and to make all participants feel seen, confirmed and involved. PMID:17672911
Ozaki, N; Tokumitsu, H; Kojima, K; Kindaichi, T
2007-01-01
In order to consider the total atmospheric loadings of the PAHs (polycyclic aromatic hydrocarbons) from traffic activities, the emission factors of PAHs were estimated and from the obtained emission factors and vehicle transportation statistics, total atmospheric loadings were integrated and the loadings into the water body were estimated on a regional scale. The atmospheric concentration of PAHs was measured at the roadside of a road with heavy traffic in the Hiroshima area in Japan. The samplings were conducted in summer and winter. Atmospheric particulate matters (fine particle, 0.6-7 microm; coarse particle, over 7 microm) and their PAH concentration were measured. Also, four major emission sources (gasoline and diesel vehicle emissions, tire and asphalt debris) were assumed for vehicle transportation activities, the chemical mass balance method was applied and the source partitioning at the roadside was estimated. Furthermore, the dispersion of atmospheric particles from the vehicles was modelled and the emission factors of the sources were determined by the comparison to the chemical mass balance results. Based on emission factors derived from the modelling, an atmospheric dispersion model of nationwide scale (National Institute of Advanced Industrial Science and Technology - Atmospheric Dispersion Model for Exposure and Risk assessment) was applied, and the atmospheric concentration and loading to the ground were calculated for the Hiroshima Bay watershed area.
Blanco, Carlos; García-Anaya, María; Wall, Melanie; de Los Cobos, José Carlos Pérez; Swierad, Ewelina; Wang, Shuai; Petry, Nancy M
2015-05-01
Pathological gambling (PG) is now aligned with substance use disorders in the DSM-5 as the first officially recognized behavioral addiction. There is growing interest in examining obesity as an addictive disorder as well. The goal of this study was to investigate whether epidemiological data provide support for the consideration of PG and obesity as addictive disorders. Factor analysis of data from a large, nationally representative sample of US adults (N=43,093), using nicotine dependence, alcohol dependence, drug dependence, PG and obesity as indicators. It was hypothesized that nicotine dependence, alcohol dependence and drug use dependence would load on a single factor. It was further hypothesized that if PG and obesity were addictive disorders, they would load on the same factor as substance use disorders, whereas failure to load on the addictive factor would not support their conceptualization as addictive disorders. A model with one factor including nicotine dependence, alcohol dependence, drug dependence and PG, but not obesity, provided a very good fit to the data, as indicated by CFI=0.99, TLI=0.99 and RMSEA=0.01 and loadings of all indicators >0.4. Data from this study support the inclusion of PG in a latent factor with substance use disorders but do not lend support to the consideration of obesity, as defined by BMI, as an addictive disorder. Future research should investigate whether certain subtypes of obesity are best conceptualized as addictive disorders and the shared biological and environmental factors that account for the common and specific features of addictive disorders. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Correlation of neonatal intensive care unit performance across multiple measures of quality of care.
Profit, Jochen; Zupancic, John A F; Gould, Jeffrey B; Pietz, Kenneth; Kowalkowski, Marc A; Draper, David; Hysong, Sylvia J; Petersen, Laura A
2013-01-01
To examine whether high performance on one measure of quality is associated with high performance on others and to develop a data-driven explanatory model of neonatal intensive care unit (NICU) performance. We conducted a cross-sectional data analysis of a statewide perinatal care database. Risk-adjusted NICU ranks were computed for each of 8 measures of quality selected based on expert input. Correlations across measures were tested using the Pearson correlation coefficient. Exploratory factor analysis was used to determine whether underlying factors were driving the correlations. Twenty-two regional NICUs in California. In total, 5445 very low-birth-weight infants cared for between January 1, 2004, and December 31, 2007. Pneumothorax, growth velocity, health care-associated infection, antenatal corticosteroid use, hypothermia during the first hour of life, chronic lung disease, mortality in the NICU, and discharge on any human breast milk. The NICUs varied substantially in their clinical performance across measures of quality. Of 28 unit-level correlations, 6 were significant (ρ < .05). Correlations between pairs of measures of quality of care were strong (ρ ≥ .5) for 1 pair, moderate (range, ρ ≥ .3 to ρ < .5) for 8 pairs, weak (range, ρ ≥ .1 to ρ < .3) for 5 pairs, and negligible (ρ < .1) for 14 pairs. Exploratory factor analysis revealed 4 underlying factors of quality in this sample. Pneumothorax, mortality in the NICU, and antenatal corticosteroid use loaded on factor 1; growth velocity and health care-associated infection loaded on factor 2; chronic lung disease loaded on factor 3; and discharge on any human breast milk loaded on factor 4. In this sample, the ability of individual measures of quality to explain overall quality of neonatal intensive care was modest.
Correlation of Neonatal Intensive Care Unit Performance Across Multiple Measures of Quality of Care
Profit, J; Zupancic, JAF; Gould, JB; Pietz, K; Kowalkowski, MA; Draper, D; Hysong, SJ; Petersen, LA
2014-01-01
Objectives To examine whether high performance on one measure of quality is associated with high performance on others and to develop a data-driven explanatory model of neonatal intensive care unit (NICU) performance. Design We conducted a cross-sectional data analysis of a statewide perinatal care database. Risk-adjusted NICU ranks were computed for each of 8 measures of quality selected based on expert input. Correlations across measures were tested using the Pearson correlation coefficient. Exploratory factor analysis was used to determine whether underlying factors were driving the correlations. Setting Twenty-two regional NICUs in California. Patients In total, 5445 very low-birth-weight infants cared for between January 1, 2004, and December 31, 2007. Main Outcomes Measures Pneumothorax, growth velocity, health care–associated infection, antenatal corticosteroid use, hypothermia during the first hour of life, chronic lung disease, mortality in the NICU, and discharge on any human breast milk. Results The NICUs varied substantially in their clinical performance across measures of quality. Of 28 unit-level correlations only 6 were significant (P < .05). Correlations between pairs of quality measures were strong (ρ > .5) for 1 pair, moderate (.3 < |ρ| < .5) for 8 pairs, weak (.1 < |ρ| < .3) for 5 pairs and negligible (|ρ| < .1) for 14 pairs. Exploratory factor analysis revealed 4 underlying factors of quality in this sample. Pneumothorax, mortality in the NICU, and antenatal corticosteroid use loaded on factor 1; growth velocity and health care–associated infection loaded on factor 2; chronic lung disease loaded on factor 3; and discharge on any human breast milk loaded on factor 4. Conclusion In this sample, the ability of individual measures of quality to explain overall quality of neonatal intensive care was modest. PMID:23403539
Unidimensional factor models imply weaker partial correlations than zero-order correlations.
van Bork, Riet; Grasman, Raoul P P P; Waldorp, Lourens J
2018-06-01
In this paper we present a new implication of the unidimensional factor model. We prove that the partial correlation between two observed variables that load on one factor given any subset of other observed variables that load on this factor lies between zero and the zero-order correlation between these two observed variables. We implement this result in an empirical bootstrap test that rejects the unidimensional factor model when partial correlations are identified that are either stronger than the zero-order correlation or have a different sign than the zero-order correlation. We demonstrate the use of the test in an empirical data example with data consisting of fourteen items that measure extraversion.
14 CFR 91.521 - Shoulder harness.
Code of Federal Regulations, 2010 CFR
2010-01-01
... inertia load factors established under the certification basis of the airplane. (b) No person may operate... used; and (2) Safety belt and shoulder harness restraint systems may be designed to the inertia load...
14 CFR 91.521 - Shoulder harness.
Code of Federal Regulations, 2013 CFR
2013-01-01
... inertia load factors established under the certification basis of the airplane. (b) No person may operate... used; and (2) Safety belt and shoulder harness restraint systems may be designed to the inertia load...
14 CFR 91.521 - Shoulder harness.
Code of Federal Regulations, 2014 CFR
2014-01-01
... inertia load factors established under the certification basis of the airplane. (b) No person may operate... used; and (2) Safety belt and shoulder harness restraint systems may be designed to the inertia load...
14 CFR 91.521 - Shoulder harness.
Code of Federal Regulations, 2011 CFR
2011-01-01
... inertia load factors established under the certification basis of the airplane. (b) No person may operate... used; and (2) Safety belt and shoulder harness restraint systems may be designed to the inertia load...
14 CFR 91.521 - Shoulder harness.
Code of Federal Regulations, 2012 CFR
2012-01-01
... inertia load factors established under the certification basis of the airplane. (b) No person may operate... used; and (2) Safety belt and shoulder harness restraint systems may be designed to the inertia load...
Principal Effects of Axial Load on Moment-Distribution Analysis of Rigid Structures
NASA Technical Reports Server (NTRS)
James, Benjamin Wylie
1935-01-01
This thesis presents the method of moment distribution modified to include the effect of axial load upon the bending moments. This modification makes it possible to analyze accurately complex structures, such as rigid fuselage trusses, that heretofore had to be analyzed by approximate formulas and empirical rules. The method is simple enough to be practicable even for complex structures, and it gives a means of analysis for continuous beams that is simpler than the extended three-moment equation now in common use. When the effect of axial load is included, it is found that the basic principles of moment distribution remain unchanged, the only difference being that the factors used, instead of being constants for a given member, become functions of the axial load. Formulas have been developed for these factors, and curves plotted so that their applications requires no more work than moment distribution without axial load. Simple problems have been included to illustrate the use of the curves.
Gand, Adeline; Hindié, Mathilde; Chacon, Diane; Van Tassel, Paul R; Pauthe, Emmanuel
2014-01-01
Biomaterials capable of delivering controlled quantities of bioactive agents, while maintaining mechanical integrity, are needed for a variety of cell contacting applications. We describe here a nanotemplating strategy toward porous, polyelectrolyte-based thin films capable of controlled biomolecular loading and release. Films are formed via the layer-by-layer assembly of charged polymers and nanoparticles (NP), then chemically cross-linked to increase mechanical rigidity and stability, and finally exposed to tetrahydrofuran to dissolve the NP and create an intra-film porous network. We report here on the loading and release of the growth factor bone morphogenetic protein 2 (BMP-2), and the influence of BMP-2 loaded films on contacting murine C2C12 myoblasts. We observe nanotemplating to enable stable BMP-2 loading throughout the thickness of the film, and find the nanotemplated film to exhibit comparable cell adhesion, and enhanced cell differentiation, compared with a non-porous cross-linked film (where BMP-2 loading is mainly confined to the film surface).
Analysis of operational limit of an aircraft: An aeroelastic approach
NASA Astrophysics Data System (ADS)
Hasan, Md. Mehedi; Hassan, M. D. Mehedi; Sarrowar, S. M. Bayazid; Faisal, Kh. Md.; Ahmed, Sheikh Reaz, Dr.
2017-06-01
In classical theory of elasticity, external loading acting on the body is independent of deformation of the body. But, in aeroelasticity, aerodynamic forces depend on the attitude of the body relative to the flow. Aircraft's are subjected to a range of static loads resulting from equilibrium or steady flight maneuvers such as coordinated level turn, steady pitch and bank rate, steady and level flight. Interaction of these loads with elastic forces of aircraft structure creates some aeroelastic phenomena. In this paper, we have summarized recent developments in the area of aeroelasticity. A numerical approach has been applied for finding divergence speed, a static aeroelastic phenomena, of a typical aircraft. This paper also involves graphical representations of constraints on load factor and bank angle during different steady flight maneuvers taking flexibility into account and comparing it with the value without flexibility. Effect of wing skin thickness, spar web thickness and position of flexural axis of wing on this divergence speed as well as load factor and bank angle has also been observed using MATLAB.
Vondrova, Diana; Kapsdorfer, Daniela; Argalasova, Lubica; Hirosova, Katarina; Samohyl, Martin; Sevcikova, Ludmila
2017-03-01
Children develop rapidly and many exogenous determinants of health significantly affect their somatic and mental development. There is a subjective perception of cognitive load associated with the educational process. The aim of the study is to assess individual environmental, behavioral and psychosocial factors influencing physical health and to investigate the amount of mental load in children. We investigated 87 schoolchildren (47 girls and 40 boys) aged 10-12 years, who were attending primary school in Bratislava. To assess values of selected factors we used a questionnaire form and personality characteristics were estimated by standardized psycho-diagnostic and IQ tests [range of classic fear, social-situation anxiety and jitters [skala Klasickeho strachu a Socialno-situacnej (in Slovak)] (KSAT), Eyesenck Personality Questionnaire for children (EPQ), Raven's IQ test]. Self-reported perception of mental load was assessed by questionnaire of subjective feelings and states (SFS). Children's body parameters were assessed using anthropometric measurements [height, weight, chest, abdominal and hip girth, Rohrer's index (RI), body mass index (BMI)] and a body fat measurement method (skinfold thickness). The results confirmed a significant relationship between higher parameters of overweight and obesity and irregular breakfast eating (p<0.05), absence of family dining (p<0.05), exposure to tobacco smoke in the family environment (p<0.01) and mother's level of education (p<0.05). Almost 60% of children reported high mental effort and cognitive load associated with the educational process. We note a close relationship between the higher mental load and the score of neuroticism (p<0.01). The physical and mental health of schoolchildren is significantly affected by exogenous factors. Therefore, in terms of protection and promotion of children's health, it is important to evaluate and monitor environmental risk factors and to form their healthy habits.
Deletion of Nrf2 reduces skeletal mechanical properties and decreases load-driven bone formation.
Sun, Yong-Xin; Li, Lei; Corry, Kylie A; Zhang, Pei; Yang, Yang; Himes, Evan; Mihuti, Cristina Layla; Nelson, Cecilia; Dai, Guoli; Li, Jiliang
2015-05-01
Nuclear factor erythroid 2-related factor 2 (Nrf2) is a transcription factor expressed in many cell types, including osteoblasts, osteocytes, and osteoclasts. Nrf2 has been considered a master regulator of cytoprotective genes against oxidative and chemical insults. The lack of Nrf2 can induce pathologies in multiple organs. The aim of this study was to investigate the role of Nrf2 in load-driven bone metabolism using Nrf2 knockout (KO) mice. Compared to age-matched littermate wild-type controls, Nrf2 KO mice have significantly lowered femoral bone mineral density (-7%, p<0.05), bone formation rate (-40%, p<0.05), as well as ultimate force (-11%, p<0.01). The ulna loading experiment showed that Nrf2 KO mice were less responsive than littermate controls, as indicated by reduction in relative mineralizing surface (rMS/BS, -69%, p<0.01) and relative bone formation rate (rBFR/BS, -84%, p<0.01). Furthermore, deletion of Nrf2 suppressed the load-driven gene expression of antioxidant enzymes and Wnt5a in cultured primary osteoblasts. Taken together, the results suggest that the loss-of-function mutation of Nrf2 in bone impairs bone metabolism and diminishes load-driven bone formation. Copyright © 2015 Elsevier Inc. All rights reserved.
Shoulder joint loading and posture during medicine cart pushing task.
Xu, Xu; Lin, Jia-Hua; Boyer, Jon
2013-01-01
Excessive physical loads and awkward shoulder postures during pushing and pulling are risk factors for shoulder pain. Pushing a medicine cart is a major component of a work shift for nurses and medical assistants in hospitals and other health care facilities. A laboratory experiment was conducted to examine the effects of common factors (e.g., lane congestion, cart load stability, floor surface friction) on shoulder joint moment and shoulder elevation angle of participants during cart pushing. Participants pushed a medicine cart on straight tracks and turning around right-angle corners. Peak shoulder joint moments reached 25.1 Nm, 20.3 Nm, and 26.8 Nm for initial, transition, and turning phases of the pushing tasks, indicating that shoulder joint loading while pushing a medical cart is comparable to levels previously reported from heavy manual activities encountered in industry (e.g., garbage collection). Also, except for user experience, all other main study factors, including congestion level, cart load stability, location of transition strip, shoulder tendency, surface friction, and handedness, significantly influenced shoulder joint moment and shoulder elevation angle. The findings provide a better understanding of shoulder exposures associated with medicine cart operations and may be helpful in designing and optimizing the physical environment where medicine carts are used.
Solid Rocket Booster Hydraulic Pump Port Cap Joint Load Testing
NASA Technical Reports Server (NTRS)
Gamwell, W. R.; Murphy, N. C.
2004-01-01
The solid rocket booster uses hydraulic pumps fabricated from cast C355 aluminum alloy, with 17-4 PH stainless steel pump port caps. Corrosion-resistant steel, MS51830 CA204L self-locking screw thread inserts are installed into C355 pump housings, with A286 stainless steel fasteners installed into the insert to secure the pump port cap to the housing. In the past, pump port cap fasteners were installed to a torque of 33 Nm (300 in-lb). However, the structural analyses used a significantly higher nut factor than indicated during tests conducted by Boeing Space Systems. When the torque values were reassessed using Boeing's nut factor, the fastener preload had a factor of safety of less than 1, with potential for overloading the joint. This paper describes how behavior was determined for a preloaded joint with a steel bolt threaded into steel inserts in aluminum parts. Finite element models were compared with test results. For all initial bolt preloads, bolt loads increased as external applied loads increased. For higher initial bolt preloads, less load was transferred into the bolt, due to external applied loading. Lower torque limits were established for pump port cap fasteners and additional limits were placed on insert axial deformation under operating conditions after seating the insert with an initial preload.
Tasaka, Akinori; Kikuchi, Manaki; Nakanishi, Kousuke; Ueda, Takayuki; Yamashita, Shuichiro; Sakurai, Kaoru
2018-01-01
The objective of the present study was to investigate the relationship between masticatory function-related factors (masticatory performance, occlusal contact area, maximum bite force, number of chewing strokes, and muscle activity) and the stress-relieving effects of chewing. A total of 28 healthy male subjects were instructed to rest or chew for 10min after 30min of stress loading with arithmetic calculations. Their stress state was assessed by measuring salivary cortisol levels. Saliva was collected at three time points: before stress loading, immediately after stress loading, and 10min after stress loading. Compared to resting, chewing produced a significantly greater reduction in the rate of change in salivary cortisol levels 10min after stress loading. A negative correlation was observed between the rate of decrease in salivary cortisol levels and the number of chewing strokes. No significant correlation was observed between the rate of decrease in salivary cortisol levels and other measurement items. In healthy dentulous people, the number of chewing strokes has been shown to be a masticatory function-related factor that affects stress relief from chewing, suggesting the possibility that more appropriate chewing would produce a greater effect psychological stress relief. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Characterizing the uncertainty in holddown post load measurements
NASA Technical Reports Server (NTRS)
Richardson, J. A.; Townsend, J. S.
1993-01-01
In order to understand unexpectedly erratic load measurements in the launch-pad supports for the space shuttle, the sensitivities of the load cells in the supports were analyzed using simple probabilistic techniques. NASA engineers use the loads in the shuttle's supports to calculate critical stresses in the shuttle vehicle just before lift-off. The support loads are measured with 'load cells' which are actually structural components of the mobile launch platform which have been instrumented with strain gauges. Although these load cells adequately measure vertical loads, the horizontal load measurements have been erratic. The load measurements were simulated in this study using Monte Carlo simulation procedures. The simulation studies showed that the support loads are sensitive to small deviations in strain and calibration. In their current configuration, the load cells will not measure loads with sufficient accuracy to reliably calculate stresses in the shuttle vehicle. A simplified model of the holddown post (HDP) load measurement system was used to study the effect on load measurement accuracy for several factors, including load point deviations, gauge heights, and HDP geometry.
NASA Technical Reports Server (NTRS)
Bubsey, R. T.; Pierce, W. S.; Shannon, J. L., Jr.; Munz, D.
1982-01-01
The short rod chevron-notch specimen has the advantages of (1) crack development at the chevron tip during the early stage of test loading, and (2) convenient calculation of plane-strain fracture toughness from the maximum test load and from a calibration factor which depends only on the specimen geometry and manner of loading. For generalized application, calibration of the specimen over a range of specimen proportions and chevron-notch configurations is necessary. Such was the objective of this investigation, wherein calibration of the short rod specimen was made by means of experimental compliance measurements converted into dimensionless stress intensity factor coefficients.
The Unintentional Memory Load in Tests for Young Children.
ERIC Educational Resources Information Center
Jones, Margaret Hubbard
The validity of certain standardized tests may be affected by the short-term memory load therein and its relation to a child's short-term memory capacity. Factors of testing which increase a test's memory load and consequently interfere with comprehension are discussed. It is hypothesized that a test which strains the short-term memory capacity of…
36 CFR 1192.23 - Mobility aid accessibility.
Code of Federal Regulations, 2010 CFR
2010-07-01
... subpart shall provide a level-change mechanism or boarding device (e.g., lift or ramp) complying with... 22 feet in length or less. (b) Vehicle lift—(1) Design load. The design load of the lift shall be at... upon which the lift depends for support of the load, shall have a safety factor of at least six, based...
36 CFR 1192.23 - Mobility aid accessibility.
Code of Federal Regulations, 2011 CFR
2011-07-01
... subpart shall provide a level-change mechanism or boarding device (e.g., lift or ramp) complying with... 22 feet in length or less. (b) Vehicle lift—(1) Design load. The design load of the lift shall be at... upon which the lift depends for support of the load, shall have a safety factor of at least six, based...
Declining sediment loads from Redwood Creek and the Klamath River, north coastal California
Randy D. Klein; Jeffrey K. Anderson
2012-01-01
River basin sediment loads are affected by several factors, with flood magnitude and watershed erosional stability playing dominant and dynamic roles. Long-term average sediment loads for northern California river basins have been computed by several researchers by several methods. However, characterizing the dynamic nature of climate and watershed stability requires...
Renal Response to Acid Load after Phenformin
Rooth, Gösta; Bandman, Ulf
1973-01-01
Normally the kidneys respond to an acid load by increased ammonia production. In six patients with adult-type diabetes this response was reduced by a mean 50% after a therapeutic dose of phenformin. The reduced ability to compensate for acid loads may be one factor leading to metabolic acidosis and lactoacidosis sometimes associated with phenformin therapy. PMID:4753235
NASA Astrophysics Data System (ADS)
Zhuk, Ya A.; Senchenkov, I. K.
1999-02-01
Certain aspects of the correct definitions of stress and strain concentration factors for elastic-viscoplastic solids under cyclic loading are discussed. Problems concerning the harmonic kinematic excitation of cylindrical specimens with a lateral V-notch are examined. The behavior of the material of a cylinder is modeled using generalized flow theory. An approximate model based on the concept of complex moduli is used for comparison. Invariant characteristics such as stress and strain intensities and maximum principal stress and strain are chosen as constitutive quantities for concentration-factor definitions. The behavior of time-varying factors is investigated. Concentration factors calculated in terms of the amplitudes of the constitutive quantities are used as representative characteristics over the cycle of vibration. The dependences of the concentration factors on the loads are also studied. The accuracy of Nueber's and Birger's formulas is evaluated. The solution of the problem in the approximate formulation agrees with its solution in the exact formulation. The possibilities of the approximate model for estimating low-cycle fatigue are evaluated.
Platelet lysate and chondroitin sulfate loaded contact lenses to heal corneal lesions.
Sandri, Giuseppina; Bonferoni, Maria Cristina; Rossi, Silvia; Delfino, Alessio; Riva, Federica; Icaro Cornaglia, Antonia; Marrubini, Giorgio; Musitelli, Giorgio; Del Fante, Claudia; Perotti, Cesare; Caramella, Carla; Ferrari, Franca
2016-07-25
Hemoderivative tear substitutes contain various ephiteliotrophic factors, such as growth factors (GF), involved in ocular surface homeostasis without immunogenic properties. The aim of the present work was the loading of platelet lysate into contact lenses to improve the precorneal permanence of platelet lysate growth factors on the ocular surface to enhance the treatment of corneal lesions. To this purpose, chondroitin sulfate, a sulfated glycosaminoglycan, which is normally present in the extracellular matrix, was associated with platelet lysate. In fact, chondroitin sulfate is capable of electrostatic interaction with positively charged growth factors, in particular, with bFGF, IGF, VEGF, PDGF and TGF-β, resulting in their stabilization and reduced degradation in solution. In the present work, various types of commercially available contact lenses have been loaded with chondroitin sulfate or chondroitin sulfate in association with platelet lysate to achieve a release of growth factors directly onto the corneal surface lesions. One type of contact lenses (PureVision(®)) showed in vitro good proliferation properties towards corneal cells and were able to enhance cut closure in cornea constructs. Copyright © 2016 Elsevier B.V. All rights reserved.
Study on Mechanical Properties of Barite Concrete under Impact Load
NASA Astrophysics Data System (ADS)
Chen, Z. F.; Cheng, K.; Wu, D.; Gan, Y. C.; Tao, Q. W.
2018-03-01
In order to research the mechanical properties of Barite concrete under impact load, a group of concrete compression tests was carried out under the impact load by using the drop test machine. A high-speed camera was used to record the failure process of the specimen during the impact process. The test results show that:with the increase of drop height, the loading rate, the peak load, the strain under peak load, the strain rate and the dynamic increase factor (DIF) all increase gradually. The ultimate tensile strain is close to each other, and the time of impact force decreases significantly, showing significant strain rate effect.
Factors that affect the fatigue strength of power transmission shafting and their impact on design
NASA Technical Reports Server (NTRS)
Leowenthal, S. H.
1986-01-01
A long standing objective in the design of power transmission shafting is to eliminate excess shaft material without compromising operational reliability. A shaft design method is presented which accounts for variable amplitude loading histories and their influence on limited life designs. The effects of combined bending and torsional loading are considered along with a number of application factors known to influence the fatigue strength of shafting materials. Among the factors examined are surface condition, size, stress concentration, residual stress and corrosion fatigue.
The effect of transverse shear in a cracked plate under skew-symmetric loading
NASA Technical Reports Server (NTRS)
Delale, F.; Erdogan, F.
1979-01-01
The problem of an elastic plate containing a through crack and subjected to twisting moments or transverse shear loads is considered. By using a bending theory which allows the satisfaction of the boundary conditions on the crack surface regarding the normal and the twisting moments and the transverse shear load separately, it is found that the resulting asymptotic stress field around the crack tip becomes identical to that given by the elasticity solutions of the plane strain and antiplane shear problems. The problem is solved for uniformly distributed or concentrated twisting moment or transverse shear load and the normalized Mode II and Mode III stress-intensity factors are tabulated. The results also include the effect of the Poisson's ratio and material orthotropy for specially orthotropic materials on the stress-intensity factors.
Numerical calibration of the stable poisson loaded specimen
NASA Technical Reports Server (NTRS)
Ghosn, Louis J.; Calomino, Anthony M.; Brewer, Dave N.
1992-01-01
An analytical calibration of the Stable Poisson Loaded (SPL) specimen is presented. The specimen configuration is similar to the ASTM E-561 compact-tension specimen with displacement controlled wedge loading used for R-Curve determination. The crack mouth opening displacements (CMOD's) are produced by the diametral expansion of an axially compressed cylindrical pin located in the wake of a machined notch. Due to the unusual loading configuration, a three-dimensional finite element analysis was performed with gap elements simulating the contact between the pin and specimen. In this report, stress intensity factors, CMOD's, and crack displacement profiles are reported for different crack lengths and different contacting conditions. It was concluded that the computed stress intensity factor decreases sharply with increasing crack length, thus making the SPL specimen configuration attractive for fracture testing of brittle, high modulus materials.
Analytical stress intensity solution for the Stable Poisson Loaded specimen
NASA Technical Reports Server (NTRS)
Ghosn, Louis J.; Calomino, Anthony M.; Brewer, David N.
1993-01-01
An analytical calibration of the Stable Poisson Loaded (SPL) specimen is presented. The specimen configuration is similar to the ASTM E-561 compact-tension specimen with displacement controlled wedge loading used for R-curve determination. The crack mouth opening displacements (CMODs) are produced by the diametral expansion of an axially compressed cylindrical pin located in the wake of a machined notch. Due to the unusual loading configuration, a three-dimensional finite element analysis was performed with gap elements simulating the contact between the pin and specimen. In this report, stress intensity factors, CMODs, and crack displacement profiles, are reported for different crack lengths and different contacting conditions. It was concluded that the computed stress intensity factor decreases sharply with increasing crack length thus making the SPL specimen configuration attractive for fracture testing of brittle, high modulus materials.
NASA Technical Reports Server (NTRS)
Hancock, P. A.; Robinson, M. A.
1989-01-01
The present experiment examined the influence of several task-related factors on tracking performance and concomitant workload. The manipulated factors included tracking order, the presence or absence of knowledge of performance, and the control device. Summed root mean square error (rmse) and perceived workload were measured at the termination of each trial. Perceived workload was measured using the NASA Task Load Index (TLX) and the Subjective Workload Assessment Technique (SWAT). Results indicated a large and expected effect for track order on both performance and the perception of load. In general, trackball input was more accurate and judged for lower load than input using a mouse. The presence or absence of knowledge of performance had little effect on either performance or workload. There were a number of interactions between factors shown in performance that were mirrored by perceived workload scores. Results from each workload scale were equivalent in terms of sensitivity to task manipulations. The pattern of results affirm the utility of these workload measures in assessing the imposed load of multiple task-related variables.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Modern, energy-efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate the impactmore » of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.« less
Bearing Capacity Assessment on low Volume Roads
NASA Astrophysics Data System (ADS)
Zariņš, A.
2015-11-01
A large part of Latvian road network consists of low traffic volume roads and in particular of roads without hard pavement. Unbounded pavements shows serious problems in the form of rutting and other deformations, which finally lead to weak serviceability and damage of the road structure after intensive exploitation periods. Traditionally, these problems have been associated with heavy goods transport, overloaded vehicles and their impact. To find the specific damaging factors causing road pavement deformations and evaluate their prevention possibilities, and establish conditions that will allow doing it, the study was carried out. The tire pressure has been set as the main factor of load. Two different tire pressures have been used in tests and their impacts were compared. The comparison was done using deflection measurements with LWD together with dielectric constant measurements in a road structure using percometer. Measurements were taken in the upper pavement structure layers at different depths during full-scale loading and in different moisture/temperature conditions. Advisable load intensity and load factors for heavy traffic according to road conditions were set based on the study results.
Risk Assessment of Heating, Ventilating, and Air-Conditioning Strategies in Low-Load Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew
2016-02-17
"Modern, energy efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate themore » impact of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luke Chen; Hsu-Cheng Chang
An air pollutant (CO) distribution in a typical street canyon is simulated to evaluate pedestrian exposure. In this study, we consider factors those may affect the pollutant distribution in a typical street canyon. The considered factors include aspect ratio of a street canyon, atmospheric stability, traffic load and turbulent buoyancy effect. A two-dimensional domain that includes suburban roughness and urban street canyon is considered. The factors such as atmospheric stability, traffic load and turbulent buoyancy are imposed through the associated boundary conditions. With numerical simulation, the critical aspect ration of a street canyon the includes two vortices and results inmore » pollutant accumulation are found. The buoyant effect is found to raise the same pollutant concentration up to the position higher than the results come out from the case without buoyancy. The pedestrian exposure to the street air pollutant under various traffic loads and atmospheric stability are evaluated. This study conclude that the local building regulations that specify the building height/street width ratio will not cause significant pedestrian exposure to the street air pollution in most of traffic loads and atmospheric stability conditions.« less
NASA Astrophysics Data System (ADS)
Pasasa, Linus; Marbun, Parlin; Mariza, Ita
2015-09-01
The purpose of this paper is to study and analyse the factors affecting customer decisions in using electricity at peak-load hours (between 17.00 to 22.00 WIB) and their behaviors towards electricity conservation in Indonesian household. The underlying rationale is to influence a reduction in energy consumption by stimulating energy saving behaviors, thereby reducing the impact of energy use on the environment. How is the correlation between the decisions in using electricity during peak load hours with the household customer's behavior towards saving electricity? The primary data is obtained by distributing questionnaires to customers of PT. PLN Jakarta Raya and Tangerang Distribution from Household segment. The data is analysed using the Structural Equation Model (SEM) and AMOS Software. The research is finding that all factors (Personal, Social, PLN Services, Psychological, and Cultural) are positively influence customer decision in using electricity at peak load hours. There is a correlation between the decisions in using electricity during peak load hours with the household customer's behavior towards saving electricity.
Using change-point models to estimate empirical critical loads for nitrogen in mountain ecosystems.
Roth, Tobias; Kohli, Lukas; Rihm, Beat; Meier, Reto; Achermann, Beat
2017-01-01
To protect ecosystems and their services, the critical load concept has been implemented under the framework of the Convention on Long-range Transboundary Air Pollution (UNECE) to develop effects-oriented air pollution abatement strategies. Critical loads are thresholds below which damaging effects on sensitive habitats do not occur according to current knowledge. Here we use change-point models applied in a Bayesian context to overcome some of the difficulties when estimating empirical critical loads for nitrogen (N) from empirical data. We tested the method using simulated data with varying sample sizes, varying effects of confounding variables, and with varying negative effects of N deposition on species richness. The method was applied to the national-scale plant species richness data from mountain hay meadows and (sub)alpine scrubs sites in Switzerland. Seven confounding factors (elevation, inclination, precipitation, calcareous content, aspect as well as indicator values for humidity and light) were selected based on earlier studies examining numerous environmental factors to explain Swiss vascular plant diversity. The estimated critical load confirmed the existing empirical critical load of 5-15 kg N ha -1 yr -1 for (sub)alpine scrubs, while for mountain hay meadows the estimated critical load was at the lower end of the current empirical critical load range. Based on these results, we suggest to narrow down the critical load range for mountain hay meadows to 10-15 kg N ha -1 yr -1 . Copyright © 2016 Elsevier Ltd. All rights reserved.
Jiang, Luhua; Liu, Yunguo; Hu, Xinjiang; Zeng, Guangming; Wang, Hui; Zhou, Lu; Tan, Xiaofei; Huang, Binyan; Liu, Shaobo; Liu, Simian
2016-01-01
With the unique advantages of lower operational and maintenance cost, the use of microbial-earthworm ecofilters (MEEs) for the wastewater treatment has been increasing rapidly in the recent years. This paper provided an overview of the research activities on the use of MEEs for removing pollutants from various wastewater throughout the world. However, the long-term effective treatment performance and sustainable operation of this system still remain a challenge since the treatment performance would be affected by design parameters, operational conditions, and environmental factors. In order to promote the treatment performance, therefore, this paper also provided and summarized the influencing factors of pollutants removal in MEEs. The design parameters and operational conditions of MEEs include earthworm species and load, filter media type, hydraulic loading rate, nutrient load, packing bed height, chemical factors and temperature. Lastly, this review highlighted the further research on these issues to improve performance and sustainability of MEEs. Copyright © 2015 Elsevier Ltd. All rights reserved.
Well-being as a moving target: measurement equivalence of the Bradburn Affect Balance Scale.
Maitland, S B; Dixon, R A; Hultsch, D F; Hertzog, C
2001-03-01
Although the Bradburn Affect Balance scale (ABS) is a frequently used two-factor indicator of well-being in later life, its measurement and invariance properties are not well documented. We examined these issues using confirmatory factor analyses of cross-sectional (adults ages 54-87 years) and longitudinal data from the Victoria Longitudinal Study. Stability of the positive and negative affect factors was moderate across a 3-year period. Overall, factor loadings for positive affect items were invariant over time with the exception of the pleased item. Negative affect items were time invariant. However, age-group comparisons between young-old and old-old groups revealed age differences in loadings for the upset item at Time 1. Finally, gender groups differed in loadings for the top of the world and going your way items. Thus a pattern of partial measurement equivalence characterized item response to the ABS. Our results suggest that group comparisons and longitudinal change in ABS scale scores of positive and negative affect should be interpreted with caution.
Anomolous Fatigue Crack Growth Phenomena in High-Strength Steel
NASA Technical Reports Server (NTRS)
Forth, Scott C.; James, Mark A.; Johnston, William M., Jr.; Newman, James C., Jr.
2004-01-01
The growth of a fatigue crack through a material is the result of a complex interaction between the applied loading, component geometry, three-dimensional constraint, load history, environment, material microstructure and several other factors. Previous studies have developed experimental and computational methods to relate the fatigue crack growth rate to many of the above conditions, with the intent of discovering some fundamental material response, i.e. crack growth rate as a function of something. Currently, the technical community uses the stress intensity factor solution as a simplistic means to relate fatigue crack growth rate to loading, geometry and all other variables. The stress intensity factor solution is a very simple linear-elastic representation of the continuum mechanics portion of crack growth. In this paper, the authors present fatigue crack growth rate data for two different high strength steel alloys generated using standard methods. The steels exhibit behaviour that appears unexplainable, compared to an aluminium alloy presented as a baseline for comparison, using the stress intensity factor solution.
Bayesian Factor Analysis as a Variable Selection Problem: Alternative Priors and Consequences
Lu, Zhao-Hua; Chow, Sy-Miin; Loken, Eric
2016-01-01
Factor analysis is a popular statistical technique for multivariate data analysis. Developments in the structural equation modeling framework have enabled the use of hybrid confirmatory/exploratory approaches in which factor loading structures can be explored relatively flexibly within a confirmatory factor analysis (CFA) framework. Recently, a Bayesian structural equation modeling (BSEM) approach (Muthén & Asparouhov, 2012) has been proposed as a way to explore the presence of cross-loadings in CFA models. We show that the issue of determining factor loading patterns may be formulated as a Bayesian variable selection problem in which Muthén and Asparouhov’s approach can be regarded as a BSEM approach with ridge regression prior (BSEM-RP). We propose another Bayesian approach, denoted herein as the Bayesian structural equation modeling with spike and slab prior (BSEM-SSP), which serves as a one-stage alternative to the BSEM-RP. We review the theoretical advantages and disadvantages of both approaches and compare their empirical performance relative to two modification indices-based approaches and exploratory factor analysis with target rotation. A teacher stress scale data set (Byrne, 2012; Pettegrew & Wolf, 1982) is used to demonstrate our approach. PMID:27314566
Yang, Xi; Han, Guoqiang; Cai, Hongmin; Song, Yan
2017-03-31
Revealing data with intrinsically diagonal block structures is particularly useful for analyzing groups of highly correlated variables. Earlier researches based on non-negative matrix factorization (NMF) have been shown to be effective in representing such data by decomposing the observed data into two factors, where one factor is considered to be the feature and the other the expansion loading from a linear algebra perspective. If the data are sampled from multiple independent subspaces, the loading factor would possess a diagonal structure under an ideal matrix decomposition. However, the standard NMF method and its variants have not been reported to exploit this type of data via direct estimation. To address this issue, a non-negative matrix factorization with multiple constraints model is proposed in this paper. The constraints include an sparsity norm on the feature matrix and a total variational norm on each column of the loading matrix. The proposed model is shown to be capable of efficiently recovering diagonal block structures hidden in observed samples. An efficient numerical algorithm using the alternating direction method of multipliers model is proposed for optimizing the new model. Compared with several benchmark models, the proposed method performs robustly and effectively for simulated and real biological data.
Buchanan, Drew; Ural, Ani
2010-08-01
Distal forearm fracture is one of the most frequently observed osteoporotic fractures, which may occur as a result of low energy falls such as falls from a standing height and may be linked to the osteoporotic nature of the bone, especially in the elderly. In order to prevent the occurrence of radius fractures and their adverse outcomes, understanding the effect of both extrinsic and intrinsic contributors to fracture risk is essential. In this study, a nonlinear fracture mechanics-based finite element model is applied to human radius to assess the influence of extrinsic factors (load orientation and load distribution between scaphoid and lunate) and intrinsic bone properties (age-related changes in fracture properties and bone geometry) on the Colles' fracture load. Seven three-dimensional finite element models of radius were created, and the fracture loads were determined by using cohesive finite element modeling, which explicitly represented the crack and the fracture process zone behavior. The simulation results showed that the load direction with respect to the longitudinal and dorsal axes of the radius influenced the fracture load. The fracture load increased with larger angles between the resultant load and the dorsal axis, and with smaller angles between the resultant load and longitudinal axis. The fracture load also varied as a function of the load ratio between the lunate and scaphoid, however, not as drastically as with the load orientation. The fracture load decreased as the load ratio (lunate/scaphoid) increased. Multiple regression analysis showed that the bone geometry and the load orientation are the most important variables that contribute to the prediction of the fracture load. The findings in this study establish a robust computational fracture risk assessment method that combines the effects of intrinsic properties of bone with extrinsic factors associated with a fall, and may be elemental in the identification of high fracture risk individuals as well as in the development of fracture prevention methods including protective falling techniques. The additional information that this study brings to fracture identification and prevention highlights the promise of fracture mechanics-based finite element modeling in fracture risk assessment.
ERIC Educational Resources Information Center
Chen, Youzhen; Lian, Rong; Yang, Lixian; Liu, Jianrong; Meng, Yingfang
2017-01-01
The effects of working memory (WM) demand and reminders on an event-based prospective memory (PM) task were compared between students with low and high achievement in math. WM load (1- and 2-back tasks) was manipulated as a within-subject factor and reminder (with or without reminder) as a between-subject factor. Results showed that high-achieving…
Adaptation to high throughput batch chromatography enhances multivariate screening.
Barker, Gregory A; Calzada, Joseph; Herzer, Sibylle; Rieble, Siegfried
2015-09-01
High throughput process development offers unique approaches to explore complex process design spaces with relatively low material consumption. Batch chromatography is one technique that can be used to screen chromatographic conditions in a 96-well plate. Typical batch chromatography workflows examine variations in buffer conditions or comparison of multiple resins in a given process, as opposed to the assessment of protein loading conditions in combination with other factors. A modification to the batch chromatography paradigm is described here where experimental planning, programming, and a staggered loading approach increase the multivariate space that can be explored with a liquid handling system. The iterative batch chromatography (IBC) approach is described, which treats every well in a 96-well plate as an individual experiment, wherein protein loading conditions can be varied alongside other factors such as wash and elution buffer conditions. As all of these factors are explored in the same experiment, the interactions between them are characterized and the number of follow-up confirmatory experiments is reduced. This in turn improves statistical power and throughput. Two examples of the IBC method are shown and the impact of the load conditions are assessed in combination with the other factors explored. Copyright © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Dutch Musculoskeletal Questionnaire: description and basic qualities.
Hildebrandt, V H; Bongers, P M; van Dijk, F J; Kemper, H C; Dul, J
2001-10-10
A questionnaire ('Dutch Musculoskeletal Questionnaire', DMQ) for the analysis of musculoskeletal workload and associated potential hazardous working conditions as well as musculoskeletal symptoms in worker populations is described and its qualities are explored using a database of 1575 workers in various occupations who completed the questionnaire. The 63 questions on musculoskeletal workload and associated potentially hazardous working conditions can be categorized into seven indices (force, dynamic and static load, repetitive load, climatic factors, vibration and ergonomic environmental factors). Together with four separate questions on standing, sitting, walking and uncomfortable postures, the indices constitute a brief overview of the main findings on musculoskeletal workload and associated potentially hazardous working conditions. Homogeneity of the indices is satisfactory. The divergent validity of the indices is fair when compared with an index of psychosocial working conditions and discomfort during exposure to physical loads. Worker groups with contrasting musculoskeletal loads can be differentiated on the basis of the indices and other factors. With respect to the concurrent validity, it appears that most indices and factors show significant associations with low back and/or neck-shoulder symptoms. This questionnaire can be used as a simple and quick inventory for occupational health services to identify worker groups in which a more thorough ergonomic analysis is indicated.
Determination of current loads of floating platform for special purposes
NASA Astrophysics Data System (ADS)
Ma, Guang-ying; Yao, Yun-long; Zhao, Chen-yao
2017-08-01
This article studied a new floating offshore platform for special purposes, which was assembled by standard floating modules. The environmental load calculation of the platform is an important part of the research of the ocean platform, which has always been paid attention to by engineers. In addition to wave loads, the wind loads and current loads are also important environmental factors that affect the dynamic response of the offshore platform. The current loads on the bottom structure should not be ignored. By Fluent software, the hydrostatic conditions and external current loads of the platform were calculated in this paper. The coefficient which is independent of the current velocity, namely, current force coefficient, can be fitted through current loads, which can be used for the consequent hydrodynamic and mooring analyses.
Noguera, Antonio; Carvajal, Ana; Alonso-Babarro, Alberto; Chisholm, Gary; Bruera, Eduardo; Centeno, Carlos
2014-01-01
The Memorial Delirium Assessment Scale (MDAS) is a reliable and validated instrument with which to assess delirium. However, MDAS responsiveness has only been investigated in an indirect way. Also, neurobehavioral and global cognitive factors seem to be the MDAS main factor loads. The primary objective of this study was to evaluate MDAS responsiveness and analyze individual factors on this scale. The secondary objective was to confirm concurrent validity and reliability of the Spanish version of the MDAS. The translation-back translation method was used to obtain the Spanish version of the MDAS. Delirium diagnosis was determined by the clinical Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision criteria and with the Confusion Assessment Method. Responsiveness and factor loadings were determined with the Delirium Rating Scale-Revised-98, the Mini-Mental State Examination (MMSE), and the MDAS at baseline (0 hours) and at 72 hours. Variation in the scores of the Delirium Rating Scale-Revised-98 shows a correlation of r = 0.93, with variation in MDAS scores at P < 0.001. Variation in MMSE scores shows a correlation of r = -0.84, with variation in MDAS scores at P = 0.015. Factor I, neurobehavioral (reduced awareness, reduced attention, perceptual disturbance, delusions, altered psychomotor activity, and sleep-wake cycle disturbance), correlated moderately with the MMSE at -0.56. Factor II, global cognitive (disorientation, short-term memory impairment, impaired digit span, and disorganized thinking), correlated strongly with the MMSE at -0.81. Factor II was significantly more reliable than Factor I, rho = 0.7, P = 0.01. The high responsiveness confirms the value of the MDAS for ongoing delirium assessment. Two differentiated factor loadings point to a potential future need for MDAS subscales. Copyright © 2014 U.S. Cancer Pain Relief Committee. All rights reserved.
NASA Astrophysics Data System (ADS)
Aftah Syukron, Ahmad; Marzuki, Ahmad; Setyawan, Ary
2017-11-01
Road network plays very important role in economic development. Overweight is one of the main factors contributing to road damage. To minimize this factor, road authority has to make sure that all vehicles operate in according to maximum vehicle regulation set by the government. The one solution can use from this problem is Weight in motion (WIM) technology. WIM technology allows measuring vehicle weight quickly. The sensor is one of the important components in the WIM system. This paper presents a model of WIM fiber sensor work based on bend loss. Fiber sensor has made by coiling optical fiber. Coiling optical fiber has managed in the elliptical shape rubber coil. Rubber coil then is planted in the pad of sensor. The principle of this sensor is a detecting of the shift light intensity output of optical fiber when the vehicles a passing through on fiber sensor. Loading was carried out using loaded truck model. Data was carried out with variations of load and load positions in the truck. The results can be concluded that the shift light intensity is greater with the more shift loads. The loader of the truck has also resulted in the greater loss. Loads in the truck distributed on the axles due to the position of loads.
Cell type-selective disease-association of genes under high regulatory load
Galhardo, Mafalda; Berninger, Philipp; Nguyen, Thanh-Phuong; Sauter, Thomas; Sinkkonen, Lasse
2015-01-01
We previously showed that disease-linked metabolic genes are often under combinatorial regulation. Using the genome-wide ChIP-Seq binding profiles for 93 transcription factors in nine different cell lines, we show that genes under high regulatory load are significantly enriched for disease-association across cell types. We find that transcription factor load correlates with the enhancer load of the genes and thereby allows the identification of genes under high regulatory load by epigenomic mapping of active enhancers. Identification of the high enhancer load genes across 139 samples from 96 different cell and tissue types reveals a consistent enrichment for disease-associated genes in a cell type-selective manner. The underlying genes are not limited to super-enhancer genes and show several types of disease-association evidence beyond genetic variation (such as biomarkers). Interestingly, the high regulatory load genes are involved in more KEGG pathways than expected by chance, exhibit increased betweenness centrality in the interaction network of liver disease genes, and carry longer 3′ UTRs with more microRNA (miRNA) binding sites than genes on average, suggesting a role as hubs integrating signals within regulatory networks. In summary, epigenetic mapping of active enhancers presents a promising and unbiased approach for identification of novel disease genes in a cell type-selective manner. PMID:26338775
Quantifying Training Loads in Contemporary Dance.
Jeffries, Annie C; Wallace, Lee; Coutts, Aaron J
2017-07-01
To describe the training demands of contemporary dance and determine the validity of using the session rating of perceived exertion (sRPE) to monitor exercise intensity and training load in this activity. In addition, the authors examined the contribution of training (ie, accelerometry and heart rate) and non-training-related factors (ie, sleep and wellness) to perceived exertion during dance training. Training load and ActiGraphy for 16 elite amateur contemporary dancers were collected during a 49-d period, using heart-rate monitors, accelerometry, and sRPE. Within-individual correlation analysis was used to determine relationships between sRPE and several other measures of training intensity and load. Stepwise multiple regressions were used to determine a predictive equation to estimate sRPE during dance training. Average weekly training load was 4283 ± 2442 arbitrary units (AU), monotony 2.13 ± 0.92 AU, strain 10677 ± 9438 AU, and average weekly vector magnitude load 1809,707 ± 1015,402 AU. There were large to very large within-individual correlations between training-load sRPE and various other internal and external measures of intensity and load. The stepwise multiple-regression analysis also revealed that 49.7% of the adjusted variance in training-load sRPE was explained by peak heart rate, metabolic equivalents, soreness, motivation, and sleep quality (y = -4.637 + 13.817%HR peak + 0.316 METS + 0.100 soreness + 0.116 motivation - 0.204 sleep quality). The current findings demonstrate the validity of the sRPE method for quantifying training load in dance, that dancers undertake very high training loads, and a combination of training and nontraining factors contribute to perceived exertion in dance training.
NASA Astrophysics Data System (ADS)
Thawinkarn, Dawruwan
2018-01-01
This research aims to analyze factors of science teacher leadership in the Thailand World-Class Standard Schools. The research instrument was a five scale rating questionnaire with reliability 0.986. The sample group included 500 science teachers from World-Class Standard Schools who had been selected by using the stratified random sampling technique. Factor analysis of science teacher leadership in the Thailand World-Class Standard Schools was conducted by using M plus for Windows. The results are as follows: The results of confirmatory factor analysis on science teacher leadership in the Thailand World-Class Standard Schools revealed that the model significantly correlated with the empirical data. The consistency index value was x2 = 105.655, df = 88, P-Value = 0.086, TLI = 0.997, CFI = 0.999, RMSEA = 0.022, and SRMR = 0.019. The value of factor loading of science teacher leadership was positive, with statistical significance at the level of 0.01. The value of six factors was between 0.880-0.996. The highest factor loading was the professional learning community, followed by child-centered instruction, participation in development, the role model in teaching, transformational leaders, and self-development with factor loading at 0.996, 0.928, 0.911, 0.907, 0.901, and 0.871, respectively. The reliability of each factor was 99.1%, 86.0%, 83.0%, 82.2%, 81.0%, and 75.8%, respectively.
Sheffield, K Megan; Butcher, Michael T; Shugart, S Katherine; Gander, Jennifer C; Blob, Richard W
2011-08-01
Skeletal elements are usually able to withstand several times their usual load before they yield, and this ratio is known as the bone's safety factor. Limited studies on amphibians and non-avian reptiles have shown that they have much higher limb bone safety factors than birds and mammals. It has been hypothesized that this difference is related to the difference in posture between upright birds and mammals and sprawling ectotherms; however, limb bone loading data from a wider range of sprawling species are needed in order to determine whether the higher safety factors seen in amphibians and non-avian reptiles are ancestral or derived conditions. Tegus (family Teiidae) are an ideal lineage with which to expand sampling of limb bone loading mechanics for sprawling taxa, particularly for lizards, because they are from a different clade than previously sampled iguanas and exhibit different foraging and locomotor habits (actively foraging carnivore versus burst-activity herbivore). We evaluated the mechanics of locomotor loading for the femur of the Argentine black and white tegu (Tupinambus merianae) using three-dimensional measurements of the ground reaction force and hindlimb kinematics, in vivo bone strains and femoral mechanical properties. Peak bending stresses experienced by the femur were low (tensile: 10.4 ± 1.1 MPa; compressive: -17.4 ± 0.9 MPa) and comparable to those in other reptiles, with moderate shear stresses and strains also present. Analyses of peak femoral stresses and strains led to estimated safety factor ranges of 8.8-18.6 in bending and 7.8-17.5 in torsion, both substantially higher than typical for birds and mammals but similar to other sprawling tetrapods. These results broaden the range of reptilian and amphibian taxa in which high femoral safety factors have been evaluated and further indicate a trend for the independent evolution of lower limb bone safety factors in endothermic taxa.
NASA Astrophysics Data System (ADS)
Saleh, D.; Domagalski, J. L.
2012-12-01
Sources and factors affecting the transport of total nitrogen are being evaluated for a study area that covers most of California and some areas in Oregon and Nevada, by using the SPARROW model (SPAtially Referenced Regression On Watershed attributes) developed by the U.S. Geological Survey. Mass loads of total nitrogen calculated for monitoring sites at stream gauging stations are regressed against land-use factors affecting nitrogen transport, including fertilizer use, recharge, atmospheric deposition, stream characteristics, and other factors to understand how total nitrogen is transported under average conditions. SPARROW models have been used successfully in other parts of the country to understand how nutrients are transported, and how management strategies can be formulated, such as with Total Maximum Daily Load (TMDL) assessments. Fertilizer use, atmospheric deposition, and climatic data were obtained for 2002, and loads for that year were calculated for monitored streams and point sources (mostly from wastewater treatment plants). The stream loads were calculated by using the adjusted maximum likelihood estimation method (AMLE). River discharge and nitrogen concentrations were de-trended in these calculations in order eliminate the effect of temporal changes on stream load. Effluent discharge information as well as total nitrogen concentrations from point sources were obtained from USEPA databases and from facility records. The model indicates that atmospheric deposition and fertilizer use account for a large percentage of the total nitrogen load in many of the larger watersheds throughout the study area. Point sources, on the other hand, are generally localized around large cities, are considered insignificant sources, and account for a small percentage of the total nitrogen loads throughout the study area.
2012-01-01
Background The autism rate has recently increased to 1 in 100 children. Genetic studies demonstrate poorly understood complexity. Environmental factors apparently also play a role. Magnetic resonance imaging (MRI) studies demonstrate increased brain sizes and altered connectivity. Electroencephalogram (EEG) coherence studies confirm connectivity changes. However, genetic-, MRI- and/or EEG-based diagnostic tests are not yet available. The varied study results likely reflect methodological and population differences, small samples and, for EEG, lack of attention to group-specific artifact. Methods Of the 1,304 subjects who participated in this study, with ages ranging from 1 to 18 years old and assessed with comparable EEG studies, 463 children were diagnosed with autism spectrum disorder (ASD); 571 children were neuro-typical controls (C). After artifact management, principal components analysis (PCA) identified EEG spectral coherence factors with corresponding loading patterns. The 2- to 12-year-old subsample consisted of 430 ASD- and 554 C-group subjects (n = 984). Discriminant function analysis (DFA) determined the spectral coherence factors' discrimination success for the two groups. Loading patterns on the DFA-selected coherence factors described ASD-specific coherence differences when compared to controls. Results Total sample PCA of coherence data identified 40 factors which explained 50.8% of the total population variance. For the 2- to 12-year-olds, the 40 factors showed highly significant group differences (P < 0.0001). Ten randomly generated split half replications demonstrated high-average classification success (C, 88.5%; ASD, 86.0%). Still higher success was obtained in the more restricted age sub-samples using the jackknifing technique: 2- to 4-year-olds (C, 90.6%; ASD, 98.1%); 4- to 6-year-olds (C, 90.9%; ASD 99.1%); and 6- to 12-year-olds (C, 98.7%; ASD, 93.9%). Coherence loadings demonstrated reduced short-distance and reduced, as well as increased, long-distance coherences for the ASD-groups, when compared to the controls. Average spectral loading per factor was wide (10.1 Hz). Conclusions Classification success suggests a stable coherence loading pattern that differentiates ASD- from C-group subjects. This might constitute an EEG coherence-based phenotype of childhood autism. The predominantly reduced short-distance coherences may indicate poor local network function. The increased long-distance coherences may represent compensatory processes or reduced neural pruning. The wide average spectral range of factor loadings may suggest over-damped neural networks. PMID:22730909
Dynamic Magnification Factor in a Box-Shape Steel Girder
NASA Astrophysics Data System (ADS)
Rahbar-Ranji, A.
2014-01-01
The dynamic effect of moving loads on structures is treated as a dynamic magnification factor when resonant is not imminent. Studies have shown that the calculated magnification factors from field measurements could be higher than the values specified in design codes. It is the main aim of present paper to investigate the applicability and accuracy of a rule-based expression for calculation of dynamic magnification factor for lifting appliances used in marine industry. A steel box shape girder of a crane is considered and transient dynamic analysis using computer code ANSYS is implemented. Dynamic magnification factor is calculated for different loading conditions and compared with rule-based equation. The effects of lifting speeds, acceleration, damping ratio and position of cargo are examined. It is found that rule-based expression underestimate dynamic magnification factor.
Assessment of modification factors for a row of bolts or timber connectors
Thomas Lee Wilkinson
1980-01-01
When bolts or timber connectors are used in a row, with load applied parallel to the row, load will be unequally distributed among the fasteners. This study assessed methods of predicting this unequal load distribution, looked at how joint variables can affect the distribution, and compared the predictions with data existing in the literature. Presently used design...
77 FR 58970 - Special Conditions: Embraer S.A. Model EMB-550 Airplanes, Sudden Engine Stoppage
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-25
... factor. The criteria for the more-severe events would no longer be a purely static torque-load condition... combines 1g flight loads with the transient dynamic loads resulting from: (a) The loss of any fan... the adoption of the final rules. #0; #0; #0; #0;#0;Federal Register / Vol. 77, No. 186 / Tuesday...
Code of Federal Regulations, 2011 CFR
2011-07-01
... percent reduction in the long-term average daily BOD5 load of the raw (untreated) process wastewater, multiplied by a variability factor of 3.0. (1) The long-term average daily BOD5 load of the raw process... concentration value reflecting a reduction in the long-term average daily COD load in the raw (untreated...
Code of Federal Regulations, 2010 CFR
2010-07-01
... percent reduction in the long-term average daily BOD5 load of the raw (untreated) process wastewater, multiplied by a variability factor of 3.0. (1) The long-term average daily BOD5 load of the raw process... concentration value reflecting a reduction in the long-term average daily COD load in the raw (untreated...
USDA-ARS?s Scientific Manuscript database
Transportation is known to be a multi-faceted stressor, with the process of loading being one of the most significant factors impacting the stress to which animals are exposed. This project was designed to determine if using a conveyor to load pigs into the top deck of a simulated straight deck trai...
1980-07-01
Arnold. Some further insight into the problem is obtained here, however, when it is demonstrated that highly optimized structural designs may...aircraft of this type are normally designed to withstand loads up to 1.5 times the maximum limit load (load factor 8.0 to 8.67), the structure should...on the wing, for example, give rise to concentrated drag and chordwise loadings as does the recoil from firing wing mounted gun systems . The drag on
A carrier sensed multiple access protocol for high data base rate ring networks
NASA Technical Reports Server (NTRS)
Foudriat, E. C.; Maly, Kurt J.; Overstreet, C. Michael; Khanna, S.; Paterra, Frank
1990-01-01
The results of the study of a simple but effective media access protocol for high data rate networks are presented. The protocol is based on the fact that at high data rates networks can contain multiple messages simultaneously over their span, and that in a ring, nodes used to detect the presence of a message arriving from the immediate upstream neighbor. When an incoming signal is detected, the node must either abort or truncate a message it is presently sending. Thus, the protocol with local carrier sensing and multiple access is designated CSMA/RN. The performance of CSMA/RN with TTattempt and truncate is studied using analytic and simulation models. Three performance factors, wait or access time, service time and response or end-to-end travel time are presented. The service time is basically a function of the network rate, it changes by a factor of 1 between no load and full load. Wait time, which is zero for no load, remains small for load factors up to 70 percent of full load. Response time, which adds travel time while on the network to wait and service time, is mainly a function of network length, especially for longer distance networks. Simulation results are shown for CSMA/RN where messages are removed at the destination. A wide range of local and metropolitan area network parameters including variations in message size, network length, and node count are studied. Finally, a scaling factor based upon the ratio of message to network length demonstrates that the results, and hence, the CSMA/RN protocol, are applicable to wide area networks.
Yan, Wenxia; Liu, Hanping; Deng, Xiaoyuan; Jin, Ying; Wang, Ning; Chu, Jing
2018-03-01
The regional injection of connective tissue growth factor (CTGF) for diabetic wound healing requires multiple components and results in a substantial loss of its biological activity. Acellular dermal matrix (ADM) scaffolds are optimal candidates for delivering these factors to local ischaemic environments. In this study, we explored whether CTGF loaded on ADM scaffolds can enhance fibronectin (FN) expression to accelerate diabetic wound healing via the protein kinase C (PKC) signalling pathway. The performance of CTGF and CTGF + PKC inhibitor, which were loaded on ADM scaffolds to treat dorsal skin wounds in streptozotocin-induced diabetic mice, was evaluated with naked ADM as a control. Wound closure showed that ADM scaffolds loaded with CTGF induced greater diabetic wound healing in the early stage of the wound in diabetic mice. Moreover, ADM scaffolds loaded with CTGF obviously increased the expression of FN both at the mRNA and protein levels, whereas the expression of FN was significantly reduced in the inhibitor group. Furthermore, the ADM + CTGF group, which produce FN, obviously promoted alpha-smooth muscle actin and transforming growth factor-beta expression and enhanced neovasculature and collagen synthesis at the wound sites. ADM scaffolds loaded with CTGF + PKC inhibitor delayed diabetic wound healing, indicating that FN expression was mediated by the PKC signalling pathway. Our findings offer new perspectives for the treatment of diabetic wound healing and suggest a rationale for the clinical evaluation of CTGF use in diabetic wound healing. Copyright © 2017 John Wiley & Sons, Ltd.
Probabilistic model of bridge vehicle loads in port area based on in-situ load testing
NASA Astrophysics Data System (ADS)
Deng, Ming; Wang, Lei; Zhang, Jianren; Wang, Rei; Yan, Yanhong
2017-11-01
Vehicle load is an important factor affecting the safety and usability of bridges. An statistical analysis is carried out in this paper to investigate the vehicle load data of Tianjin Haibin highway in Tianjin port of China, which are collected by the Weigh-in- Motion (WIM) system. Following this, the effect of the vehicle load on test bridge is calculated, and then compared with the calculation result according to HL-93(AASHTO LRFD). Results show that the overall vehicle load follows a distribution with a weighted sum of four normal distributions. The maximum vehicle load during the design reference period follows a type I extremum distribution. The vehicle load effect also follows a weighted sum of four normal distributions, and the standard value of the vehicle load is recommended as 1.8 times that of the calculated value according to HL-93.
ERIC Educational Resources Information Center
Hwang, Ming-Yueh; Hong, Jon-Chao; Cheng, Hao-Yueh; Peng, Yu-Chi; Wu, Nien-Chen
2013-01-01
Do girls have more competition anxiety and exogenous cognitive load than equally able boys during the playing of stressful competitive on-line games? This question led to the adoption of a technology acceptance model to compare the influence factors of competitors in sequential and synchronous games. Confirmatory factor analysis of the data on 220…
Cellular and molecular mechanisms for the bone response to mechanical loading
NASA Technical Reports Server (NTRS)
Bloomfield, S. A.
2001-01-01
To define the cellular and molecular mechanisms for the osteogenic response of bone to increased loading, several key steps must be defined: sensing of the mechanical signal by cells in bone, transduction of the mechanical signal to a biochemical one, and transmission of that biochemical signal to effector cells. Osteocytes are likely to serve as sensors of loading, probably via interstitial fluid flow produced during loading. Evidence is presented for the role of integrins, the cell's actin cytoskeleton, G proteins, and various intracellular signaling pathways in transducing that mechanical signal to a biochemical one. Nitric oxide, prostaglandins, and insulin-like growth factors all play important roles in these pathways. There is growing evidence for modulation of these mechanotransduction steps by endocrine factors, particularly parathyroid hormone and estrogen. The efficiency of this process is also impaired in the aged animal, yet what remains undefined is at what step mechanotransduction is affected.
Costigan, Patrick A; Morin, Evelyn L; Reid, Susan A
2014-01-01
In this paper, Dr. Joan Stevenson's work on assessment of the effects of lifting, supporting and transporting loads is reviewed. A defining attribute of this work is the use of objective, biomechanical measures as the basis from which a fuller understanding of all factors affecting worker performance can be obtained, and how such performance should be measured and evaluated. The central objectives and conclusions of Dr. Stevenson's research programs spanning the years from 1985 through 2012 are summarized and discussed in terms of an overall research trajectory. The guiding principle of Dr. Stevenson's work is to reduce the potential harm to which workers are exposed through the development of bona fide occupational standards, a better understanding of risk factors leading to low back pain, and the establishment of an enhanced objective design process for functional load-bearing clothing and equipment.
Temperament Factor Structure in Fragile X Syndrome: The Children's Behavior Questionnaire
Roberts, Jane E.; Tonnsen, Bridgette L.; Robinson, Marissa; McQuillin, Samuel D.; Hatton, Deborah D.
2014-01-01
Early patterns of temperament lay the foundation for a variety of developmental constructs such as self-regulation, psychopathology, and resilience. Children with fragile X syndrome (FXS) display unique patterns of temperament compared to age-matched clinical and non-clinical samples, and early patterns of temperament have been associated with later anxiety in this population. Despite these unique patterns in FXS and recent reports of atypical factor structure of temperament questionnaires in Williams Syndrome (Leyfer, John, Woodruff-Borden, & Mervis, 2012), no studies have examined the latent factor structure of temperament scales in FXS to ensure measurement validity in this sample. The present study used confirmatory factor analysis to examine the factor structure of a well-validated parent-reported temperament questionnaire, the Children's Behavior Questionnaire (Rothbart, Ahadi, Hershey, & Fisher, 2001), in a sample of 90 males with FXS ages 3-9 years. Our data produced a similar, but not identical, three-factor model that retained the original CBQ factors of negative affectivity, effortful control, and extraversion/surgency. In particular, our FXS sample demonstrated stronger factor loadings for fear and shyness than previously reported loadings in non-clinical samples, consistent with reports of poor social approach and elevated anxiety in this population. Although the original factor structure of the Children's Behavior Questionnaire is largely retained in children with FXS, differences in factor loading magnitudes may reflect phenotypic characteristics of the syndrome. These findings may inform future developmental and translational research efforts. PMID:24380785
Chen, Guobao; Lv, Yonggang
2015-01-01
Electrospun nanofibers have been extensively used in growth factor delivery and regenerative medicine due to many advantages including large surface area to volume ratio, high porosity, excellent loading capacity, ease of access and cost effectiveness. Their relatively large surface area is helpful for cell adhesion and growth factor loading, while storage and release of growth factor are essential to guide cellular behaviors and tissue formation and organization. In bone tissue engineering, growth factors are expected to transmit signals that stimulate cellular proliferation, migration, differentiation, metabolism, apoptosis and extracellular matrix (ECM) deposition. Bolus administration is not always an effective method for the delivery of growth factors because of their rapid diffusion from the target site and quick deactivation. Therefore, the integration of controlled release strategy within electrospun nanofibers can provide protection for growth factors against in vivo degradation, and can manipulate desired signal at an effective level with extended duration in local microenvironment to support tissue regeneration and repair which normally takes a much longer time. In this review, we provide an overview of growth factor delivery using biomimetic electrospun nanofiber scaffolds in bone tissue engineering. It begins with a brief introduction of different kinds of polymers that were used in electrospinning and their applications in bone tissue engineering. The review further focuses on the nanofiber-based growth factor delivery and summarizes the strategies of growth factors loading on the nanofiber scaffolds for bone tissue engineering applications. The perspectives on future challenges in this area are also pointed out.
Sewage-treatment under substantial load variations in winter tourism areas--a full case study.
Winkler, S; Matsché, N; Gamperer, T; Dum, M
2004-01-01
The sewage-load variations in winter tourism areas are characterized by sudden increases--in the range of a factor two to three--within only a few days at the start and the end of the tourist season, especially at Christmas. The sudden load increases occur during periods of low wastewater temperatures, which is an additional demanding factor with respect to nitrogen removal. A full case study was carried out at WWTP Saalfelden, which is located near one of Austria's largest skiing resorts. The plant is designed for 80,000 PE and built according to the HYBRID-concept, which is a special two stage activated sludge process for extensive nutrient removal.
Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Starke, Michael R; Onar, Omer C; DeVault, Robert C
2011-09-01
Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The powermore » system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems, sensors, and communication technologies for demand response and load factor control applications for the residential sector. The purpose is to cover the gaps that exist in the information captured by the sensors for energy management system to be able to provide demand response and load factor control. The vision is the development of an energy management system or other controlling enterprise hardware and software that is not only able to control loads, PHEVs, and renewable generation for demand response and load factor control, but also to do so with consumer comforts in mind and in an optimal fashion.« less
NASA Technical Reports Server (NTRS)
Thornton, Stephen V.
1993-01-01
A transonic fighter-bomber aircraft, having a swept supercritical wing with smooth variable-camber flaps was fitted with a maneuver load control (MLC) system that implements a technique to reduce the inboard bending moments in the wing by shifting the spanwise load distribution inboard as load factor increases. The technique modifies the spanwise camber distribution by automatically commanding flap position as a function of flap position, true airspeed, Mach number, dynamic pressure, normal acceleration, and wing sweep position. Flight test structural loads data were obtained for loads in both the wing box and the wing root. Data from uniformly deflected flaps were compared with data from flaps in the MLC configuration where the outboard segment of three flap segments was deflected downward less than the two inboard segments. The changes in the shear loads in the forward wing spar and at the roots of the stabilators also are presented. The camber control system automatically reconfigures the flaps through varied flight conditions. Configurations having both moderate and full trailing-edge flap deflection were tested. Flight test data were collected at Mach numbers of 0.6, 0.7, 0.8, and 0.9 and dynamic pressures of 300, 450, 600, and 800 lb/sq ft. The Reynolds numbers for these flight conditions ranged from 26 x 10(exp 6) to 54 x 10(exp 6) at the mean aerodynamic chord. Load factor increases of up to 1.0 g achieved with no increase in wing root bending moment with the MLC flap configuration.
Assessment of the Uniqueness of Wind Tunnel Strain-Gage Balance Load Predictions
NASA Technical Reports Server (NTRS)
Ulbrich, N.
2016-01-01
A new test was developed to assess the uniqueness of wind tunnel strain-gage balance load predictions that are obtained from regression models of calibration data. The test helps balance users to gain confidence in load predictions of non-traditional balance designs. It also makes it possible to better evaluate load predictions of traditional balances that are not used as originally intended. The test works for both the Iterative and Non-Iterative Methods that are used in the aerospace testing community for the prediction of balance loads. It is based on the hypothesis that the total number of independently applied balance load components must always match the total number of independently measured bridge outputs or bridge output combinations. This hypothesis is supported by a control volume analysis of the inputs and outputs of a strain-gage balance. It is concluded from the control volume analysis that the loads and bridge outputs of a balance calibration data set must separately be tested for linear independence because it cannot always be guaranteed that a linearly independent load component set will result in linearly independent bridge output measurements. Simple linear math models for the loads and bridge outputs in combination with the variance inflation factor are used to test for linear independence. A highly unique and reversible mapping between the applied load component set and the measured bridge output set is guaranteed to exist if the maximum variance inflation factor of both sets is less than the literature recommended threshold of five. Data from the calibration of a six{component force balance is used to illustrate the application of the new test to real-world data.
Espinosa, Yazmín; San Martín, Camila; Torres, Alejandro A.; Farfán, Mauricio J.; Torres, Juan P.; Avadhanula, Vasanthi; Piedra, Pedro A.; Tapia, Lorena I.
2017-01-01
The clinical impact of viral factors (types and viral loads) during respiratory syncytial virus (RSV) infection is still controversial, especially regarding newly described genotypes. In this study, infants with RSV bronchiolitis were recruited to describe the association of these viral factors with severity of infection. RSV antigenic types, genotypes, and viral loads were determined from hospitalized patients at Hospital Roberto del Río, Santiago, Chile. Cases were characterized by demographic and clinical information, including days of lower respiratory symptoms and severity. A total of 86 patients were included: 49 moderate and 37 severe cases. During 2013, RSV-A was dominant (86%). RSV-B predominated in 2014 (92%). Phylogenetic analyses revealed circulation of GA2, Buenos Aires (BA), and Ontario (ON) genotypes. No association was observed between severity of infection and RSV group (p = 0.69) or genotype (p = 0.87). After a clinical categorization of duration of illness, higher RSV genomic loads were detected in infants evaluated earlier in their disease (p < 0.001) and also in infants evaluated later, but coursing a more severe infection (p = 0.04). Although types and genotypes did not associate with severity in our children, higher RSV genomic loads and delayed viral clearance in severe patients define a group that might benefit from new antiviral therapies. PMID:28335547
Estimation of Gust Response Factor for a Tall Building Model with 1:1.5 Plan Ratios
NASA Astrophysics Data System (ADS)
Sarath Kumar, H.; Selvi Rajan, S.
2017-08-01
The purpose of structural analysis and design of structures as per the building codes and its corresponding standers is to ensure the safety of structure under maximum loads and remains functional under service load. The structure which is designed under consideration of codes should also satisfy the durability, economy and aesthetics. The primary purpose of this work is to understand and compare design wind loads according with the Gust Response Factor as per codes of practices. The paper is concerned with the calculation of design wind loads on a rectangular building model (1:300gemetric scale) of size 10cm x 15cm x 70cm with an aspect ratio of 1:1.5:7 at eight different levels over the height under sub-urban terrain category for 00 angle and 900 angle wind incidence. The experiment id conducted in an atmospheric boundary layer wind tunnel facility of CSIR-Structural engineering Research centre, Chennai. The measured pressures are integrated to evaluate mean and RMS (Root, Mean, Square). Further the variation of above mentioned loads and response factor along the heights of the building with respect to sub-urban terrain condition are discussed and summarized in addition, the codal values of various international standards [IS-875 part-3 1987, IS-875 part-3 draft, ASCE-07] have also considered for comparison.
Fatigue crack growth under variable amplitude loading
NASA Astrophysics Data System (ADS)
Sidawi, Jihad A.
1994-09-01
Fatigue crack growth tests were conducted on an Fe 510 E C-Mn steel and a submerged arc welded joint from the same material under constant, variable, and random loading amplitudes. Paris-Erdogan's crack growth rate law was tested for the evaluation of m and C using the stress intensity factor K, the J-integral, the effective stress intensity factor K(sub eff), and the root mean square stress intensity factor K(sub rms) fracture mechanics concepts. The effect of retardation and residual stresses resulting from welding was also considered. It was found that all concepts gave good life predictions in all cases.
Communication requirements of sparse Cholesky factorization with nested dissection ordering
NASA Technical Reports Server (NTRS)
Naik, Vijay K.; Patrick, Merrell L.
1989-01-01
Load distribution schemes for minimizing the communication requirements of the Cholesky factorization of dense and sparse, symmetric, positive definite matrices on multiprocessor systems are presented. The total data traffic in factoring an n x n sparse symmetric positive definite matrix representing an n-vertex regular two-dimensional grid graph using n exp alpha, alpha not greater than 1, processors are shown to be O(n exp 1 + alpha/2). It is O(n), when n exp alpha, alpha not smaller than 1, processors are used. Under the conditions of uniform load distribution, these results are shown to be asymptotically optimal.
NASA Technical Reports Server (NTRS)
Olson, R E; Allison, J M
1940-01-01
Report presents the results of an investigation made to determine the influence of various factors on the take-off performance of a hypothetical large flying boat by means of take-off calculations. The factors varied in the calculations were size of hull (load coefficient), wing setting, trim, deflection of flap, wing loading, aspect ratio, and parasite drag. The take-off times and distances were calculated to the stalling speeds and the performance above these speeds was separately studied to determine piloting technique for optimum take-off.
Levant, Ronald F; McDermott, Ryon C; Hewitt, Amber A; Alto, Kathleen M; Harris, Kyle T
2016-10-01
Confirmatory factor analysis of responses to the Male Role Norms Inventory-Adolescent-revised (MRNI-A-r) from 384 middle school students (163 boys, 221 girls) indicated that the best fit to the data was a bifactor model incorporating the hypothesized 3-factor structure while explicitly modeling an additional, general factor. Specifically, each item-level indicator loaded simultaneously on 2 factors: a general traditional masculinity ideology factor and a specific factor corresponding to 1 of the 3 hypothesized masculine norms for adolescents: Emotionally Detached Dominance, Toughness, and Avoidance of Femininity. Invariance testing across gender supported metric invariance for the general factor only. Although item loadings on the general factor were similar across boys and girls, the specific factor loadings varied substantially, with many becoming nonsignificant in the presence of the general factor for girls. A structural regression analysis predicting latent variables of the Meanings of Adolescent Masculinity Scale (MAMS), the Rosenberg Self-esteem Scale, and the Discipline, School Difficulties, and Positive Behavior Scale (DSDPBS) indicated that the general factor was a strong predictor of MAMS for both genders and DSDPBS for girls. Findings indicate that the MRNI-A-r general factor is a valid and reliable indicator of overall internalization of traditional masculinity ideology in adolescents; however, the specific factors may have different meanings for boys as compared with girls and lack validity in the presence of the general factor. These findings are consistent with a developmental perspective of gender ideology that views adolescence as a time when a differentiated cognitive schema of masculine norms is beginning to develop. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Mori, Michela; Rossi, Silvia; Ferrari, Franca; Bonferoni, Maria C; Sandri, Giuseppina; Riva, Federica; Tenci, Marika; Del Fante, Claudia; Nicoletti, Giovanni; Caramella, Carla
2016-03-01
Platelet lysate (PL) was loaded into dressings based on chitosan glutamate (CSG) low and high molecular weight, sericin (Ser), and glycine (Gly). A synergic effect of Ser and PL on fibroblast proliferation was proved in vitro. Two different PL loading approaches were considered: the first provided to prepare dressings by freeze-drying a mixture of PL and CSG/Gly/Ser solution, the second approach consisted in the extemporarily loading of PL in the CSG/Gly/Ser freeze-dried dressings. As for the first approach, PL loading did not produce any variation in dressing mechanical properties. Such dressings absorbed a high amount (about 8-fold of dry weight) of phosphate-buffered saline (fluid mimicking wound exudate), forming a gel with pseudoplastic and elastic properties. Platelet-derived growth factor AB assay indicated that neither freeze-drying nor the excipients alter PL growth factor content. As for the second approach, mechanical and rheological properties of the gel formed upon PL absorption enabled to choose a PL loading of about 90 μL/cm(2). Upon contact with fibroblasts, all PL loaded formulations increased the number not only of viable cells but also of those in the proliferative phase. Histological studies effected on human skin strips pointed out the positive effect of PL loaded dressings on dermal matrix reconstruction. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Hashemikia, Samaneh; Hemmatinejad, Nahid; Ahmadi, Ebrahim; Montazer, Majid
2015-04-01
Several researchers are focused on preparation of mesoporous silica as drug carriers with high loading efficiency to control or sustain the drug release. Carriers with highly loaded drug are utilized to minimize the time of drug intake. In this study, amino modified SBA-15 was synthesized through grafting with amino propyl triethoxy silane and then loaded with tetracycline hydrochloride. The drug loading was optimized by using the response surface method considering various factors including drug to silica ratio, operation time, and temperature. The drug to silica ratio indicated as the most influential factor on the drug loading yield. Further, a quadratic polynomial equation was developed to predict the loading percentage. The experimental results indicated reasonable agreement with the predicted values. The modified and drug loaded mesoporous particles were characterized by FT-IR, SEM, TEM, X-ray diffraction (XRD), elemental analysis and N2 adsorption-desorption. The release profiles of tetracycline-loaded particles were studied in different pH. Also, Higuchi equation was used to analyze the release profile of the drug and to evaluate the kinetic of drug release. The drug release rate followed the conventional Higuchi model that could be controlled by amino-functionalized SBA-15. Further, the drug delivery system based on amino modified SBA-15 exhibits novel features with an appropriate usage as an anti-bacterial drug delivery system with effective management of drug adsorption and release. Copyright © 2014 Elsevier Inc. All rights reserved.
Howard, Jeffrey T; Sparks, P Johnelle
2016-09-10
Using nationally representative data for adults of age 25 years and older from four waves of the National Health and Nutrition Examination Survey (NHANES), collected from 2003 through 2010, this study examines differences in individual health markers used to calculate allostatic load, with particular attention given to stratification by race/ethnicity and educational level. Factor analysis with maximum likelihood estimation was used. Fisher's r to z transformation test was used to determine whether or not observed differences in factor loadings were statistically significant. The findings reveal the unidimensionality of the concept of allostatic load and the underlying differences in associations between individual biomarkers and summary measures of allostatic load. Additionally, metabolic processes tend to be the most important predictor of allostatic load for all adults; however, inflammatory measures are more important in determining allostatic load scores for non-Hispanic blacks compared to non-Hispanic whites and for adults with less than a college education compared to adults with some college or a college degree. These findings highlight the continued importance of studying the concept of "weathering" or allostatic load at the population level and need to better understand how population groups facing exclusion from economic, social, and political power may internalize this position which may cause early health deterioration and ultimate mortality chance through different expression of health insults and premature aging. Am. J. Hum. Biol. 28:627-635, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Load theory behind the wheel; perceptual and cognitive load effects.
Murphy, Gillian; Greene, Ciara M
2017-09-01
Perceptual Load Theory has been proposed as a resolution to the longstanding early versus late selection debate in cognitive psychology. There is much evidence in support of Load Theory but very few applied studies, despite the potential for the model to shed light on everyday attention and distraction. Using a driving simulator, the effect of perceptual and cognitive load on drivers' visual search was assessed. The findings were largely in line with Load Theory, with reduced distractor processing under high perceptual load, but increased distractor processing under high cognitive load. The effect of load on driving behaviour was also analysed, with significant differences in driving behaviour under perceptual and cognitive load. In addition, the effect of perceptual load on drivers' levels of awareness was investigated. High perceptual load significantly increased inattentional blindness and deafness, for stimuli that were both relevant and irrelevant to driving. High perceptual load also increased RTs to hazards. The current study helps to advance Load Theory by illustrating its usefulness outside of traditional paradigms. There are also applied implications for driver safety and roadway design, as the current study suggests that perceptual and cognitive load are important factors in driver attention. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
14 CFR 25.529 - Hull and main float landing conditions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... stern landings, the limit water reaction load factors are those computed under § 25.527. In addition— (1... upward component and a side component equal, respectively, to 0.75 and 0.25 tan β times the resultant... upward load at the step of each float of 0.75 and a side load of 0.25 tan β at one float times the step...
14 CFR 25.529 - Hull and main float landing conditions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... stern landings, the limit water reaction load factors are those computed under § 25.527. In addition— (1... upward component and a side component equal, respectively, to 0.75 and 0.25 tan β times the resultant... upward load at the step of each float of 0.75 and a side load of 0.25 tan β at one float times the step...
Code of Federal Regulations, 2013 CFR
2013-07-01
... than 90 percent reduction in the long-term average daily BOD5 load of the raw (untreated) process wastewater, multiplied by a variability factor of 3.0. (1) The long-term average daily BOD5 load of the raw..., calculation of the long-term average daily BOD5 load in the influent to the wastewater treatment system must...
Code of Federal Regulations, 2012 CFR
2012-07-01
... than 90 percent reduction in the long-term average daily BOD5 load of the raw (untreated) process wastewater, multiplied by a variability factor of 3.0. (1) The long-term average daily BOD5 load of the raw..., calculation of the long-term average daily BOD5 load in the influent to the wastewater treatment system must...
Code of Federal Regulations, 2014 CFR
2014-07-01
... than 90 percent reduction in the long-term average daily BOD5 load of the raw (untreated) process wastewater, multiplied by a variability factor of 3.0. (1) The long-term average daily BOD5 load of the raw..., calculation of the long-term average daily BOD5 load in the influent to the wastewater treatment system must...
Guide to dowel load transfer systems for jointed concrete roadway pavements.
DOT National Transportation Integrated Search
2011-09-01
This guide provides a summary of the factors and design theories that should be considered when designing : dowel load transfer systems for concrete pavement systems (including dowel basket design and fabrication) and : presents recommendations for w...
Influence of load type on power factor and harmonic composition of three-phase rectifier current
NASA Astrophysics Data System (ADS)
Nikolayzin, N. V.; Vstavskaya, E. V.; Konstantinov, V. I.; Konstantinova, O. V.
2018-05-01
This article is devoted to research of the harmonic composition of the three-phase rectifier current consumed when it operates with different types of load. The results are compared with Standard requirements.
14 CFR 23.485 - Side load conditions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... positions. (b) The limit vertical load factor must be 1.33, with the vertical ground reaction divided... reaction divided between the main wheels so that— (1) 0.5 (W) is acting inboard on one side; and (2) 0.33...
Performance based design of laterally loaded drilled shafts.
DOT National Transportation Integrated Search
2013-12-01
Reliability-based design of deep foundations such as drilled shafts has been increasingly important due to the : heightened awareness of the importance of risk management. The load and resistance factor design has been : implemented by FHWA since 200...
Analysis of composite laminates with multiple fasteners by boundary collocation technique
NASA Astrophysics Data System (ADS)
Sergeev, Boris Anatolievich
Mechanical fasteners remain the primary means of load transfer between structural components made of composite laminates. As, in pursuit of increasing efficiency of the structure, the operational load continues to grow, the load carried by each fastener increases accordingly. This accelerates initiation of fatigue-related cracks near the fasteners holes and increases probability of failure. Therefore, the assessment of the stresses around the fastener holes and the stress intensity factors associated with edge cracks becomes critical for damage-tolerant design. Because of the presence of unknown contact stresses and the contact region between the fastener and the laminate, the analysis of a pin-loaded hole becomes considerably more complex than that of a traction-free hole. The accurate prediction of the contact stress distribution along the hole boundary is critical for determining the stress intensity factors and is essential for reliable strength evaluation and failure prediction. This study concerns the development of an analytical methodology, based on the boundary collocation technique, to determine the contact stresses and stress intensity factors required for strength and life prediction of bolted joints with many fasteners. It provides an analytical capability for determining the non-linear contact stresses in mechanically fastened composite laminates while capturing the effects of finite geometry, presence of edge cracks, interaction among fasteners, material anisotropy, fastener flexibility, fastener-hole clearance, friction between the pin and the laminate, and by-pass loading. Also, the proposed approach permits the determination of the fastener load distribution, which significantly influences the failure load of a multi-fastener joint. The well known phenomenon of the fastener tightening torque (clamping force) influence on the load distribution among the different fastener in a multi-fastener joints is taken into account by means of bi-linear representation of the elastic fastener deflection. Finally, two different failure criteria, maximum strains averaged over the characteristic distances and Tsai-Wu criterion, were used to predict the failure load and failure mode in two composite-aluminum joints. The comparison of the present predictions with the published experimental results reveals their agreement.
Design of a 3T preamplifier which stability is insensitive to coil loading
NASA Astrophysics Data System (ADS)
Cao, Xueming; Fischer, Elmar; Korvink, Jan G.; Gruschke, Oliver; Hennig, Jürgen; Zaitsev, Maxim
2016-04-01
In MRI (magnetic resonance imaging), preamplifiers are needed to amplify signals obtained from MRI receiver coils. Under various loading conditions of the corresponding receiver coils, preamplifiers see different source impedance at their input and may become unstable. Therefore preamplifiers which stability is not sensitive to coil loading are desirable. In this article, a coil-loading-insensitive preamplifier for MRI is presented, derived from an unstable preamplifier. Different approaches to improve stability were used during this derivation. Since a very low noise factor is essential for MRI preamplifiers, noise contributions from passive components in the MRI preamplifier have to be considered during the stabilization process. As a result, the initially unstable preamplifier became stable with regard to coil loading, while other MRI requirements, as the extremely low noise factor, were still fulfilled. The newly designed preamplifier was manufactured, characterized and tested in the MRI spectrometer. Compared to a commercially available preamplifier, the newly designed preamplifier has similar imaging performance but other advantages like smaller size and better stability. Furthermore, presented stabilization approaches can be generalized to stabilize other unstable low-noise amplifiers.
Modeling particulate matter emissions during mineral loading process under weak wind simulation.
Zhang, Xiaochun; Chen, Weiping; Ma, Chun; Zhan, Shuifen
2013-04-01
The quantification of particulate matter emissions from mineral handling is an important problem for the quantification of global emissions on industrial sites. Mineral particulate matter emissions could adversely impact environmental quality in mining regions, transport regions, and even on a global scale. Mineral loading is an important process contributing to mineral particulate matter emissions, especially under weak wind conditions. Mathematical models are effective ways to evaluate particulate matter emissions during the mineral loading process. The currently used empirical models based on the form of a power function do not predict particulate matter emissions accurately under weak wind conditions. At low particulate matter emissions, the models overestimated, and at high particulate matter emissions, the models underestimated emission factors. We conducted wind tunnel experiments to evaluate the particulate matter emission factors for the mineral loading process. A new approach based on the mathematical form of a logistical function was developed and tested. It provided a realistic depiction of the particulate matter emissions during the mineral loading process, accounting for fractions of fine mineral particles, dropping height, and wind velocity. Copyright © 2013 Elsevier B.V. All rights reserved.
[Characteristics of fugitive dust emission from paved road near construction activities].
Tian, Gang; Fan, Shou-Bin; Li, Gang; Qin, Jian-Ping
2007-11-01
Because of the mud/dirt carryout from construction activities, the silt loading of paved road nearby is higher and the fugitive dust emission is stronger. By sampling and laboratory analysis of the road surface dust samples, we obtain the silt loading (mass of material equal to or less than 75 micromaters in physical diameter per unit area of travel surface) of paved roads near construction activities. The result show that silt loading of road near construction activities is higher than "normal road", and silt loading is negatively correlated with length from construction's door. According to AP-42 emission factor model of fugitive dust from roads, the emission factor of influenced road is 2 - 10 times bigger than "normal road", and the amount of fugitive dust emission influenced by one construction activity is "equivalent" to an additional road length of approximately 422 - 3 800 m with the baseline silt loading. Based on the spatial and temporal distribution of construction activities, in 2002 the amount of PM10 emission influenced by construction activities in Beijing city areas account of for 59% of fugitive dust from roads.
Exploratory Bi-factor Analysis: The Oblique Case.
Jennrich, Robert I; Bentler, Peter M
2012-07-01
Bi-factor analysis is a form of confirmatory factor analysis originally introduced by Holzinger and Swineford (Psychometrika 47:41-54, 1937). The bi-factor model has a general factor, a number of group factors, and an explicit bi-factor structure. Jennrich and Bentler (Psychometrika 76:537-549, 2011) introduced an exploratory form of bi-factor analysis that does not require one to provide an explicit bi-factor structure a priori. They use exploratory factor analysis and a bifactor rotation criterion designed to produce a rotated loading matrix that has an approximate bi-factor structure. Among other things this can be used as an aid in finding an explicit bi-factor structure for use in a confirmatory bi-factor analysis. They considered only orthogonal rotation. The purpose of this paper is to consider oblique rotation and to compare it to orthogonal rotation. Because there are many more oblique rotations of an initial loading matrix than orthogonal rotations, one expects the oblique results to approximate a bi-factor structure better than orthogonal rotations and this is indeed the case. A surprising result arises when oblique bi-factor rotation methods are applied to ideal data.
Response of shallow geothermal energy pile from laboratory model tests
NASA Astrophysics Data System (ADS)
Marto, A.; Amaludin, A.
2015-09-01
In shallow geothermal energy pile systems, the thermal loads from the pile, transferred and stored in the soil will cause thermally induced settlement. This factor must be considered in the geotechnical design process to avoid unexpected hazards. Series of laboratory model tests were carried out to study the behaviour of energy piles installed in kaolin soil, subjected to thermal loads and a combination of axial and thermal loads (henceforth known as thermo-axial loads). Six tests which included two thermal load tests (35°C and 40°C) and four thermo-axial load tests (100 N and 200 N, combined with 35°C and 40°C thermal loads) were conducted. To simulate the behaviour of geothermal energy piles during its operation, the thermo-axial tests were carried out by applying an axial load to the model pile head, and a subsequent application of thermal load. The model soil was compacted at 90% maximum dry density and had an undrained shear strength of 37 kPa, thus classified as having a firm soil consistency. The behaviour of model pile, having the ultimate load capacity of 460 N, was monitored using a linear variable displacement transducer, load cell and wire thermocouple, to measure the pile head settlement, applied axial load and model pile temperature. The acquired data from this study was used to define the thermo-axial response characteristics of the energy pile model. In this study, the limiting settlement was defined as 10% of the model pile diameter. For thermal load tests, higher thermal loads induced higher values of thermal settlement. At 40°C thermal load an irreversible settlement was observed after the heating and cooling cycle was applied to the model pile. Meanwhile, the pile response to thermo-axial loads were attributed to soil consistency and the magnitude of both the axial and thermal loads applied to the pile. The higher the thermoaxial loads, the higher the settlements occurred. A slight hazard on the model pile was detected, since the settlement occurred was greater than the limiting value when the pile was loaded with thermo-axial loads of 40°C and 200 N. It is therefore recommended that the global factor of safety to be applied for energy pile installed in firm soil should be more than 2.3 to prevent any hazard to occur in the future, should the pile also be subjected to thermal load of 40°C or greater.
Babbin, Steven F.; Yin, Hui-Qing; Rossi, Joseph S.; Redding, Colleen A.; Paiva, Andrea L.; Velicer, Wayne F.
2015-01-01
The Self-Efficacy Scale for Sun Protection consists of two correlated factors with three items each for Sunscreen Use and Avoidance. This study evaluated two crucial psychometric assumptions, factorial invariance and scale reliability, with a sample of adults (N = 1356) participating in a computer-tailored, population-based intervention study. A measure has factorial invariance when the model is the same across subgroups. Three levels of invariance were tested, from least to most restrictive: (1) Configural Invariance (nonzero factor loadings unconstrained); (2) Pattern Identity Invariance (equal factor loadings); and (3) Strong Factorial Invariance (equal factor loadings and measurement errors). Strong Factorial Invariance was a good fit for the model across seven grouping variables: age, education, ethnicity, gender, race, skin tone, and Stage of Change for Sun Protection. Internal consistency coefficient Alpha and factor rho scale reliability, respectively, were .84 and .86 for Sunscreen Use, .68 and .70 for Avoidance, and .78 and .78 for the global (total) scale. The psychometric evidence demonstrates strong empirical support that the scale is consistent, has internal validity, and can be used to assess population-based adult samples. PMID:26457203
Suitability of the Depression, Anxiety, and Stress Scale in Parkinson's Disease.
Johnson, Andrew R; Lawrence, Blake J; Corti, Emily J; Booth, Leon; Gasson, N; Thomas, Meghan G; Loftus, A M; Bucks, Romola S
2016-05-27
The Depression, Anxiety, and Stress Scale -21 (DASS-21) is a frequently used measure of emotional disturbance symptoms in Parkinson's disease (PD). However, the factor structure of the DASS-21 in PD has yet to be explored. To assess whether the scale is measuring these symptoms in PD in the same way as the general population. The present study fit a series of established DASS-21 factor structures with both confirmatory factor analysis (CFA) and exploratory structural equation modelling (ESEM) using data from 251 participants with PD. The 3-factor ESEM provided the best fit. The depression and stress scales fit well, however, few items on the anxiety subscale loaded clearly, with several items significantly loading onto the depression or stress factors. Whilst the depression and stress subscales appear suitable in PD, poor loadings and internal consistency indicate the anxiety subscale may not accurately assess anxiety symptomology in PD. This may be due to the scale's reliance on physiological symptoms as indicators of anxiety, when many of these are present in PD. Thus, the anxiety subscale of the DASS-21 may not be a suitable measure of anxiety in PD.
Structural validity of the Dutch-language version of the WAIS-III in a psychiatric sample.
van der Heijden, Paul; van den Bos, Pancras; Mol, Bart; Kessels, Roy P C
2013-01-01
The Wechsler Adult Intelligence Scale-Fourth Edition (WAIS-IV; Wechsler, 2008 ) no longer provides the "traditional" Verbal IQ and Performance IQ deviation scores. In the current study, we investigated the structural validity of these scores in the scale's predecessor, the WAIS-Third Edition (WAIS-III; Wechsler, 1997c ), which is still widely used in clinical practice, especially outside the United States. Confirmative (CFA) and exploratory factor analyses (EFA) were performed on WAIS-III data from a Dutch sample of 247 psychiatric patients. Four competing models were tested in the CFA on 11 subtests. The model that fit the data best was a model in which subtests loaded on the four factor indexes (i.e., 3 Verbal Comprehension subtests, 3 Perceptual Organization subtests, 3 Working Memory subtests, and 2 Processing Speed subtests) as proposed by the manual (Wechsler, 1997b ). In the EFA on 13 subtests with four factors extracted, all subtests were found to load on the factors in accordance with the WAIS-III test manual. However, Picture Arrangement, Arithmetic, and Picture Completion showed only moderate loadings on the proposed factors. Implications for clinical practice are discussed.
Cell type-selective disease-association of genes under high regulatory load.
Galhardo, Mafalda; Berninger, Philipp; Nguyen, Thanh-Phuong; Sauter, Thomas; Sinkkonen, Lasse
2015-10-15
We previously showed that disease-linked metabolic genes are often under combinatorial regulation. Using the genome-wide ChIP-Seq binding profiles for 93 transcription factors in nine different cell lines, we show that genes under high regulatory load are significantly enriched for disease-association across cell types. We find that transcription factor load correlates with the enhancer load of the genes and thereby allows the identification of genes under high regulatory load by epigenomic mapping of active enhancers. Identification of the high enhancer load genes across 139 samples from 96 different cell and tissue types reveals a consistent enrichment for disease-associated genes in a cell type-selective manner. The underlying genes are not limited to super-enhancer genes and show several types of disease-association evidence beyond genetic variation (such as biomarkers). Interestingly, the high regulatory load genes are involved in more KEGG pathways than expected by chance, exhibit increased betweenness centrality in the interaction network of liver disease genes, and carry longer 3' UTRs with more microRNA (miRNA) binding sites than genes on average, suggesting a role as hubs integrating signals within regulatory networks. In summary, epigenetic mapping of active enhancers presents a promising and unbiased approach for identification of novel disease genes in a cell type-selective manner. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
Magistri, Marco; Velmeshev, Dmitry; Makhmutova, Madina; Faghihi, Mohammad Ali
2015-01-01
Abstract The underlying genetic variations of late-onset Alzheimer’s disease (LOAD) cases remain largely unknown. A combination of genetic variations with variable penetrance and lifetime epigenetic factors may converge on transcriptomic alterations that drive LOAD pathological process. Transcriptome profiling using deep sequencing technology offers insight into common altered pathways regardless of underpinning genetic or epigenetic factors and thus represents an ideal tool to investigate molecular mechanisms related to the pathophysiology of LOAD. We performed directional RNA sequencing on high quality RNA samples extracted from hippocampi of LOAD and age-matched controls. We further validated our data using qRT-PCR on a larger set of postmortem brain tissues, confirming downregulation of the gene encoding substance P (TAC1) and upregulation of the gene encoding the plasminogen activator inhibitor-1 (SERPINE1). Pathway analysis indicates dysregulation in neural communication, cerebral vasculature, and amyloid-β clearance. Beside protein coding genes, we identified several annotated and non-annotated long noncoding RNAs that are differentially expressed in LOAD brain tissues, three of them are activity-dependent regulated and one is induced by Aβ1 - 42 exposure of human neural cells. Our data provide a comprehensive list of transcriptomics alterations in LOAD hippocampi and warrant holistic approach including both coding and non-coding RNAs in functional studies aimed to understand the pathophysiology of LOAD. PMID:26402107
Skin, Stringer, and Fastener Loads in Buckled Fuselage Panels
NASA Technical Reports Server (NTRS)
Young, Richard D.; Rose, Cheryl A.; Starnes, James H., Jr.
2001-01-01
The results of a numerical study to assess the effect of skin buckling on the internal load distribution in a stiffened fuselage panel, with and without longitudinal cracks, are presented. In addition, the impact of changes in the internal loads on the fatigue life and residual strength of a fuselage panel is assessed. A generic narrow-body fuselage panel is considered. The entire panel is modeled using shell elements and considerable detail is included to represent the geometric-nonlinear response of the buckled skin, cross section deformation of the stiffening components, and details of the skin-string attachment with discrete fasteners. Results are presented for a fixed internal pressure and various combinations of axial tension or compression loads. Results illustrating the effect of skin buckling on the stress distribution in the skin and stringer, and fastener loads are presented. Results are presented for the pristine structure, and for cases where damage is introduced in the form of a longitudinal crack adjacent to the stringer, or failed fastener elements. The results indicate that axial compression loads and skin buckling can have a significant effect on the circumferential stress in the skin, and fastener loads, which will influence damage initiation, and a comparable effect on stress intensity factors for cases with cracks. The effects on stress intensity factors will influence damage propagation rates and the residual strength of the panel.
NASA Astrophysics Data System (ADS)
Khaleghi, Mohammad Reza; Varvani, Javad
2018-02-01
Complex and variable nature of the river sediment yield caused many problems in estimating the long-term sediment yield and problems input into the reservoirs. Sediment Rating Curves (SRCs) are generally used to estimate the suspended sediment load of the rivers and drainage watersheds. Since the regression equations of the SRCs are obtained by logarithmic retransformation and have a little independent variable in this equation, they also overestimate or underestimate the true sediment load of the rivers. To evaluate the bias correction factors in Kalshor and Kashafroud watersheds, seven hydrometric stations of this region with suitable upstream watershed and spatial distribution were selected. Investigation of the accuracy index (ratio of estimated sediment yield to observed sediment yield) and the precision index of different bias correction factors of FAO, Quasi-Maximum Likelihood Estimator (QMLE), Smearing, and Minimum-Variance Unbiased Estimator (MVUE) with LSD test showed that FAO coefficient increases the estimated error in all of the stations. Application of MVUE in linear and mean load rating curves has not statistically meaningful effects. QMLE and smearing factors increased the estimated error in mean load rating curve, but that does not have any effect on linear rating curve estimation.
Bradshaw, Elizabeth J; Hume, Patria A
2012-09-01
Targeted injury prevention strategies, based on biomechanical analyses, have the potential to help reduce the incidence and severity of gymnastics injuries. This review outlines the potential benefits of biomechanics research to contribute to injury prevention strategies for women's artistic gymnastics by identification of mechanisms of injury and quantification of the effects of injury risk factors. One hundred and twenty-three articles were retained for review after searching electronic databases using key words, including 'gymnastic', 'biomech*', and 'inj*', and delimiting by language and relevance to the paper aim. Impact load can be measured biomechanically by the use of instrumented equipment (e.g. beatboard), instrumentation on the gymnast (accelerometers), or by landings on force plates. We need further information on injury mechanisms and risk factors in gymnastics and practical methods of monitoring training loads. We have not yet shown, beyond a theoretical approach, how biomechanical analysis of gymnastics can help reduce injury risk through injury prevention interventions. Given the high magnitude of impact load, both acute and accumulative, coaches should monitor impact loads per training session, taking into consideration training quality and quantity such as the control of rotation and the height from which the landings are executed.
Sassani, Farrokh
2014-01-01
The simulation results for electromagnetic energy harvesters (EMEHs) under broad band stationary Gaussian random excitations indicate the importance of both a high transformation factor and a high mechanical quality factor to achieve favourable mean power, mean square load voltage, and output spectral density. The optimum load is different for random vibrations and for sinusoidal vibration. Reducing the total damping ratio under band-limited random excitation yields a higher mean square load voltage. Reduced bandwidth resulting from decreased mechanical damping can be compensated by increasing the electrical damping (transformation factor) leading to a higher mean square load voltage and power. Nonlinear EMEHs with a Duffing spring and with linear plus cubic damping are modeled using the method of statistical linearization. These nonlinear EMEHs exhibit approximately linear behaviour under low levels of broadband stationary Gaussian random vibration; however, at higher levels of such excitation the central (resonant) frequency of the spectral density of the output voltage shifts due to the increased nonlinear stiffness and the bandwidth broadens slightly. Nonlinear EMEHs exhibit lower maximum output voltage and central frequency of the spectral density with nonlinear damping compared to linear damping. Stronger nonlinear damping yields broader bandwidths at stable resonant frequency. PMID:24605063
Camacho, Ana María; Veganzones, Mariano; Claver, Juan; Martín, Francisco; Sevilla, Lorenzo; Sebastián, Miguel Ángel
2016-09-01
Tribological conditions can change drastically during heavy loaded regimes as experienced in metal forming; this is especially critical when lubrication can only be applied at the early stage of the process because the homogeneous lubricant layer can break along the die-workpiece interface. In these cases, adopting a constant friction factor for the lubricant-surface pair may not be a valid assumption. This paper presents a procedure based on the use of dual friction factor maps to determine friction factors employed in heavy loaded regimes. A finite element (FE) simulation is used to obtain the friction factor map for the alloy UNS A96082. Experiments were conducted using four lubricants (aluminum anti-size, MoS₂ grease, silicone oil, and copper paste) to determine the actual friction curves. The experimental procedure is based on the application of lubricant only at the beginning of the first stage of ring compression, and not at intermediate stages as is usual in typical ring compression tests (RCTs). The results show that for small reductions ( r h < 20%), the conventional RCT can be applied because the tribological conditions remain similar. For large reductions ( r h > 20%), it is recommended to obtain an average value of the friction factor for every lubricant-surface pair in the range of deformation considered.
Camacho, Ana María; Veganzones, Mariano; Claver, Juan; Martín, Francisco; Sevilla, Lorenzo; Sebastián, Miguel Ángel
2016-01-01
Tribological conditions can change drastically during heavy loaded regimes as experienced in metal forming; this is especially critical when lubrication can only be applied at the early stage of the process because the homogeneous lubricant layer can break along the die-workpiece interface. In these cases, adopting a constant friction factor for the lubricant-surface pair may not be a valid assumption. This paper presents a procedure based on the use of dual friction factor maps to determine friction factors employed in heavy loaded regimes. A finite element (FE) simulation is used to obtain the friction factor map for the alloy UNS A96082. Experiments were conducted using four lubricants (aluminum anti-size, MoS2 grease, silicone oil, and copper paste) to determine the actual friction curves. The experimental procedure is based on the application of lubricant only at the beginning of the first stage of ring compression, and not at intermediate stages as is usual in typical ring compression tests (RCTs). The results show that for small reductions (rh < 20%), the conventional RCT can be applied because the tribological conditions remain similar. For large reductions (rh > 20%), it is recommended to obtain an average value of the friction factor for every lubricant-surface pair in the range of deformation considered. PMID:28773868
Limited Investigation of Active Feel Control Stick System (Active Stick)
2009-06-01
contained no limit protection and was the baseline system. The second system was “F-16 like” and contained angle -of-attack and load factor limiting...system. The second system was “F-16 like” and contained angle of attack (AOA) and load factor limiting features built into the flight control system...Force PTI at VLO .......................... 13 Figure 9: Pitch Angle Response to 1.5 g Commanded Force PTI at VLO ........................ 14 Figure 10
Holden, Richard J.; Scanlon, Matthew C.; Patel, Neal R.; Kaushal, Rainu; Escoto, Kamisha Hamilton; Brown, Roger L.; Alper, Samuel J.; Arnold, Judi M.; Shalaby, Theresa M.; Murkowski, Kathleen; Karsh, Ben-Tzion
2010-01-01
Backgrounds Nursing workload is increasingly thought to contribute to both nurses’ quality of working life and quality/safety of care. Prior studies lack a coherent model for conceptualizing and measuring the effects of workload in health care. In contrast, we conceptualized a human factors model for workload specifying workload at three distinct levels of analysis and having multiple nurse and patient outcomes. Methods To test this model, we analyzed results from a cross-sectional survey of a volunteer sample of nurses in six units of two academic tertiary care pediatric hospitals. Results Workload measures were generally correlated with outcomes of interest. A multivariate structural model revealed that: the unit-level measure of staffing adequacy was significantly related to job dissatisfaction (path loading = .31) and burnout (path loading = .45); the task-level measure of mental workload related to interruptions, divided attention, and being rushed was associated with burnout (path loading = .25) and medication error likelihood (path loading = 1.04). Job-level workload was not uniquely and significantly associated with any outcomes. Discussion The human factors engineering model of nursing workload was supported by data from two pediatric hospitals. The findings provided a novel insight into specific ways that different types of workload could affect nurse and patient outcomes. These findings suggest further research and yield a number of human factors design suggestions. PMID:21228071
Wattmo, Carina; Wallin, Åsa K
2017-01-01
Whether age at onset influences functional deterioration in Alzheimer disease (AD) is unclear. We, therefore, investigated risk factors for progression in activities of daily living (ADL) and nursing home placement (NHP) in cholinesterase inhibitor (ChEI)-treated patients with early-onset AD (EOAD) versus late-onset AD (LOAD). This 3-year, prospective, observational, multicenter study included 1,017 participants with mild-to-moderate AD; 143 had EOAD (onset <65 years) and 874 LOAD (onset ≥65 years). Possible sociodemographic and clinical factors that could affect functional outcome and NHP were analyzed using mixed-effects models and logistic regression, respectively. Younger individuals exhibited longer illness duration before AD diagnosis, whereas 6-month functional response to ChEI therapy, 3-year changes in ADL capacities, time from diagnosis to NHP, and survival time in nursing homes were similar between the groups. In LOAD, a higher ChEI dose, no antidepressant use, and lower education level were protective factors for slower instrumental ADL (IADL) decline. In EOAD, antihypertensives/cardiac therapy implied faster IADL progression but lower risk of NHP. This study highlights the clinical importance of an earlier diagnosis and treatment initiation and the need for functional evaluations in EOAD. Despite the age differences between EOAD and LOAD, a similar need for nursing homes was observed.
Comparative Assessment of Models and Methods To Calculate Grid Electricity Emissions.
Ryan, Nicole A; Johnson, Jeremiah X; Keoleian, Gregory A
2016-09-06
Due to the complexity of power systems, tracking emissions attributable to a specific electrical load is a daunting challenge but essential for many environmental impact studies. Currently, no consensus exists on appropriate methods for quantifying emissions from particular electricity loads. This paper reviews a wide range of the existing methods, detailing their functionality, tractability, and appropriate use. We identified and reviewed 32 methods and models and classified them into two distinct categories: empirical data and relationship models and power system optimization models. To illustrate the impact of method selection, we calculate the CO2 combustion emissions factors associated with electric-vehicle charging using 10 methods at nine charging station locations around the United States. Across the methods, we found an up to 68% difference from the mean CO2 emissions factor for a given charging site among both marginal and average emissions factors and up to a 63% difference from the average across average emissions factors. Our results underscore the importance of method selection and the need for a consensus on approaches appropriate for particular loads and research questions being addressed in order to achieve results that are more consistent across studies and allow for soundly supported policy decisions. The paper addresses this issue by offering a set of recommendations for determining an appropriate model type on the basis of the load characteristics and study objectives.
Holden, Richard J; Scanlon, Matthew C; Patel, Neal R; Kaushal, Rainu; Escoto, Kamisha Hamilton; Brown, Roger L; Alper, Samuel J; Arnold, Judi M; Shalaby, Theresa M; Murkowski, Kathleen; Karsh, Ben-Tzion
2011-01-01
Nursing workload is increasingly thought to contribute to both nurses' quality of working life and quality/safety of care. Prior studies lack a coherent model for conceptualising and measuring the effects of workload in healthcare. In contrast, we conceptualised a human factors model for workload specifying workload at three distinct levels of analysis and having multiple nurse and patient outcomes. To test this model, we analysed results from a cross-sectional survey of a volunteer sample of nurses in six units of two academic tertiary care paediatric hospitals. Workload measures were generally correlated with outcomes of interest. A multivariate structural model revealed that: the unit-level measure of staffing adequacy was significantly related to job dissatisfaction (path loading=0.31) and burnout (path loading=0.45); the task-level measure of mental workload related to interruptions, divided attention, and being rushed was associated with burnout (path loading=0.25) and medication error likelihood (path loading=1.04). Job-level workload was not uniquely and significantly associated with any outcomes. The human factors engineering model of nursing workload was supported by data from two paediatric hospitals. The findings provided a novel insight into specific ways that different types of workload could affect nurse and patient outcomes. These findings suggest further research and yield a number of human factors design suggestions.
Conceptual and methodological concerns in the theory of perceptual load.
Benoni, Hanna; Tsal, Yehoshua
2013-01-01
The present paper provides a short critical review of the theory of perceptual load. It closely examines the basic tenets and assumptions of the theory and identifies major conceptual and methodological problems that have been largely ignored in the literature. The discussion focuses on problems in the definition of the concept of perceptual load, on the circularity in the characterization and manipulation of perceptual load and the confusion between the concept of perceptual load and its operationalization. The paper also selectively reviews evidence supporting the theory as well as inconsistent evidence which proposed alternative dominant factors influencing the efficacy of attentional selection.
Conceptual and methodological concerns in the theory of perceptual load
Benoni, Hanna; Tsal, Yehoshua
2013-01-01
The present paper provides a short critical review of the theory of perceptual load. It closely examines the basic tenets and assumptions of the theory and identifies major conceptual and methodological problems that have been largely ignored in the literature. The discussion focuses on problems in the definition of the concept of perceptual load, on the circularity in the characterization and manipulation of perceptual load and the confusion between the concept of perceptual load and its operationalization. The paper also selectively reviews evidence supporting the theory as well as inconsistent evidence which proposed alternative dominant factors influencing the efficacy of attentional selection. PMID:23964262
A novel load balanced energy conservation approach in WSN using biogeography based optimization
NASA Astrophysics Data System (ADS)
Kaushik, Ajay; Indu, S.; Gupta, Daya
2017-09-01
Clustering sensor nodes is an effective technique to reduce energy consumption of the sensor nodes and maximize the lifetime of Wireless sensor networks. Balancing load of the cluster head is an important factor in long run operation of WSNs. In this paper we propose a novel load balancing approach using biogeography based optimization (LB-BBO). LB-BBO uses two separate fitness functions to perform load balancing of equal and unequal load respectively. The proposed method is simulated using matlab and compared with existing methods. The proposed method shows better performance than all the previous works implemented for energy conservation in WSN
Probabilistic simulation of stress concentration in composite laminates
NASA Technical Reports Server (NTRS)
Chamis, C. C.; Murthy, P. L. N.; Liaw, L.
1993-01-01
A computational methodology is described to probabilistically simulate the stress concentration factors in composite laminates. This new approach consists of coupling probabilistic composite mechanics with probabilistic finite element structural analysis. The probabilistic composite mechanics is used to probabilistically describe all the uncertainties inherent in composite material properties while probabilistic finite element is used to probabilistically describe the uncertainties associated with methods to experimentally evaluate stress concentration factors such as loads, geometry, and supports. The effectiveness of the methodology is demonstrated by using it to simulate the stress concentration factors in composite laminates made from three different composite systems. Simulated results match experimental data for probability density and for cumulative distribution functions. The sensitivity factors indicate that the stress concentration factors are influenced by local stiffness variables, by load eccentricities and by initial stress fields.
Verloo, Henk; Desmedt, Mario; Morin, Diane
2017-09-01
To evaluate two psychometric properties of the French versions of the Evidence-Based Practice Beliefs and Evidence-Based Practice Implementation scales, namely their internal consistency and construct validity. The Evidence-Based Practice Beliefs and Evidence-Based Practice Implementation scales developed by Melnyk et al. are recognised as valid, reliable instruments in English. However, no psychometric validation for their French versions existed. Secondary analysis of a cross sectional survey. Source data came from a cross-sectional descriptive study sample of 382 nurses and other allied healthcare providers. Cronbach's alpha was used to evaluate internal consistency, and principal axis factor analysis and varimax rotation were computed to determine construct validity. The French Evidence-Based Practice Beliefs and Evidence-Based Practice Implementation scales showed excellent reliability, with Cronbach's alphas close to the scores established by Melnyk et al.'s original versions. Principal axis factor analysis showed medium-to-high factor loading scores without obtaining collinearity. Principal axis factor analysis with varimax rotation of the 16-item Evidence-Based Practice Beliefs scale resulted in a four-factor loading structure. Principal axis factor analysis with varimax rotation of the 17-item Evidence-Based Practice Implementation scale revealed a two-factor loading structure. Further research should attempt to understand why the French Evidence-Based Practice Implementation scale showed a two-factor loading structure but Melnyk et al.'s original has only one. The French versions of the Evidence-Based Practice Beliefs and Evidence-Based Practice Implementation scales can both be considered valid and reliable instruments for measuring Evidence-Based Practice beliefs and implementation. The results suggest that the French Evidence-Based Practice Beliefs and Evidence-Based Practice Implementation scales are valid and reliable and can therefore be used to evaluate the effectiveness of organisational strategies aimed at increasing professionals' confidence in Evidence-Based Practice, supporting its use and implementation. © 2017 John Wiley & Sons Ltd.
Embedded data collector (EDC) phase II load and resistance factor design (LRFD) : [summary].
DOT National Transportation Integrated Search
2015-07-01
Piles that support bridge structures are designed for the specific site characteristics and loads : that the piles are expected to bear. In Florida, driven piles are monitored during installation : (dynamically tested) to assess resistance, com...
Generating Fatigue Crack Growth Thresholds with Constant Amplitude Loads
NASA Technical Reports Server (NTRS)
Forth, Scott C.; Newman, James C., J.; Forman, Royce G.
2002-01-01
The fatigue crack growth threshold, defining crack growth as either very slow or nonexistent, has been traditionally determined with standardized load reduction methodologies. Some experimental procedures tend to induce load history effects that result in remote crack closure from plasticity. This history can affect the crack driving force, i.e. during the unloading process the crack will close first at some point along the wake, reducing the effective load at the crack tip. One way to reduce the effects of load history is to propagate a crack under constant amplitude loading. As a crack propagates under constant amplitude loading, the stress intensity factor, K, will increase, as will the crack growth rate, da/dN. A fatigue crack growth threshold test procedure is developed and experimentally validated that does not produce load history effects and can be conducted at a specified stress ratio, R.
NASA Technical Reports Server (NTRS)
Morris, C. E. K., Jr.; Tomaine, R. L.; Stevens, D. D.
1979-01-01
Data on performance and rotor loads for a teetering-rotor, AH-1G helicopter flown with a main rotor that had the NLR-1T airfoil as the blade-section contour are presented. The test envelope included hover, forward-flight speed sweeps from 35 to 85 m/sec, and collective-fixed maneuvers at about 0.25 tip-speed ratio. The data set for each test point described vehicle flight state, control positions, rotor loads, power requirements, and blade motions. Rotor loads are reviewed primarily in terms of peak-to-peak and harmonic content. Lower frequency components predominated for most loads and generally increased with increased airspeed, but not necessarily with increased maneuver load factor.
Axial-Load Fatigue Tests on 17-7 PH Stainless Steel Under Constant-Amplitude Loading
NASA Technical Reports Server (NTRS)
Leybold, Herbert A.
1960-01-01
Axial-load fatigue tests were conducted at room temperature on notched and unnotched sheet specimens of 17-7 PH stainless steel in Condition TH 1050. The notched specimens had theoretical stress-concentration factors of 2.32, 4.00, and 5.00. All specimens were tested under completely reversed loading. S-N curves are presented for each specimen configuration and ratios of fatigue strengths of unnotched specimens to those of notched specimens are given. Predictions of the fatigue behavior of notched specimens near the fatigue limit were made.
Elevated temperature biaxial fatigue
NASA Technical Reports Server (NTRS)
Jordan, E. H.
1983-01-01
Biaxial fatigue is often encountered in the complex thermo-mechanical loadings present in gas turbine engines. Engine strain histories can involve non-constant temperature, mean stress, creep, environmental effects, both isotropic and anisotropic materials and non-proportional loading. Life prediction for the general case involving all the above factors is not a practicable research project. The current research program is limited to isothermal fatigue at room temperature and 1200 F of Hastalloy-X for both proportional and non-proportional loading. An improved method for predicting the fatigue life and deformation response under biaxial cycle loading is sought.
Field Testing and Load Rating Report, Bridge FSBR-514, Fort Shafter, Hawaii
2009-05-01
composite model – wearing surface and railing DW 5.95 kip-in./in. Live load effect (HS-20) LL 8.55 kip-in./in. Resistance factor for steel in...and live load at Interior Beam. MCap 51.1 Kip-in/in Superimposed dead load applied to composite model – wearing surface and railing DW 5.88...with concrete studs . If the above steps are followed, it should be possible to mount each trans- ducer in approximately 5 to 10 min. The Figures C1
NASA Astrophysics Data System (ADS)
Jordan, Yuyan C.; Ghulam, Abduwasit; Hartling, Sean
2014-01-01
In this paper, spatial and temporal trajectories of land cover/land use change (LCLUC) derived from Landsat data record are combined with hydrological modeling to explore the implication of vegetation dynamics on soil erosion and total suspended sediment (TSS) loading to surface rivers. The inter-annual coefficient of variation (CoV) of normalized difference vegetation index (NDVI) is used to screen the LCLUC and climate change. The Soil and Water Assessment Tool (SWAT) is employed to identify the monthly TSS for two times interval (1991 to 2001 and 2001 to 2011) at subbasin levels. SWAT model is calibrated from 1991 to 2001 and validated from 2002 to 2011 at three USGS gauging sites located in the study area. The Spearman's rank correlation of annual mean TSS is used to assess the temporal trends of TSS dynamics in the subbasins in the two study periods. The spatial correlation among NDVI, LCLUC, climate change and TSS loading rate changes is quantified by using linear regression model and negative/positive trend analysis. Our results showed that higher rainfall yields contribute to higher TSS loading into surface waters. A higher inter-annual accumulated vegetation index and lower inter-annual CoV distributed over the uplands resulted in a lower TSS loading rate, while a relatively low vegetation index with larger CoV observed over lowlands resulted in a higher TSS loading rate. The TSS loading rate at the basin outlet increased with the decrease of annual NDVI due to expanding urban areas in the watershed. The results also suggested nonlinearity between the trends of TSS loading with any of a specific land cover change because of the fact that the contribution of a factor can be influenced by the effects of other factors. However, dominant factors that shape the relationship between the trend of TSS loading and specific land cover changes were detected. The change of forest showed a negative relationship while agriculture and pasture demonstrated positive relationships with TSS loading change. Our results do not show any significant causal relationship between urbanization and the TSS loading change suggesting that further investigation needs to be carried out to understand the mechanism of the impact of urban sprawl on surface water quality.
Hip ontogenesis: how evolution, genes, and load history shape hip morphotype and cartilotype.
Hogervorst, Tom; Eilander, Wouter; Fikkers, Joost T; Meulenbelt, Ingrid
2012-12-01
Developmental hip disorders (DHDs), eg, developmental dysplasia of the hip, slipped capitis femoris epiphysis, and femoroacetabular impingement, can be considered morphology variants of the normal hip. The femoroacetabular morphology of DHD is believed to induce osteoarthritis (OA) through local cumulative mechanical overload acting on genetically controlled patterning systems and subsequent damage of joint structures. However, it is unclear why hip morphology differs between individuals with seemingly comparable load histories and why certain hips with DHD progress to symptomatic OA whereas others do not. We asked (1) which mechanical factors influence growth and development of the proximal femur; and (2) which genes or genetic mechanisms are associated with hip ontogenesis. We performed a systematic literature review of mechanical and genetic factors of hip ontogeny. We focused on three fields that in recent years have advanced our knowledge of adult hip morphology: imaging, evolution, and genetics. WHERE ARE WE NOW?: Mechanical factors can be understood in view of human evolutionary peculiarities and may summate to load histories conducive to DHD. Genetic factors most likely act through multiple genes, each with modest effect sizes. Single genes that explain a DHD are therefore unlikely to be found. Apparently, the interplay between genes and load history not only determines hip morphotype, but also joint cartilage robustness ("cartilotype") and resistance to symptomatic OA. WHERE DO WE NEED TO GO?: We need therapies that can improve both morphotype and cartilotype. HOW DO WE GET THERE?: Better phenotyping, improving classification systems of hip morphology, and comparative population studies can be done with existing methods. Quantifying load histories likely requires new tools, but proof of principle of modifying morphotype in treatment of DDH and of cartilotype with exercise is available.
Mousavizadeh, Rouhollah; Scott, Alex; Lu, Alex; Ardekani, Gholamreza S; Behzad, Hayedeh; Lundgreen, Kirsten; Ghaffari, Mazyar; McCormack, Robert G; Duronio, Vincent
2016-06-01
Angiopoietin-like 4 (ANGPTL4) modulates tendon neovascularization. Cyclic loading stimulates the activity of transforming growth factor-β and hypoxia-inducible factor 1α and thereby increases the expression and release of ANGPTL4 from human tendon cells. Targeting ANGPTL4 and its regulatory pathways is a potential avenue for regulating tendon vascularization to improve tendon healing or adaptation. The mechanisms that regulate angiogenic activity in injured or mechanically loaded tendons are poorly understood. The present study examined the potential role of angiopoietin-like 4 (ANGPTL4) in the angiogenic response of tendons subjected to repetitive mechanical loading or injury. Cyclic stretching of human tendon fibroblasts stimulated the expression and release of ANGPTL4 protein via transforming growth factor-β (TGF-β) and hypoxia-inducible factor 1α (HIF-1α) signalling, and the released ANGPTL4 was pro-angiogenic. Angiogenic activity was increased following ANGPTL4 injection into mouse patellar tendons, whereas the patellar tendons of ANGPTL4 knockout mice displayed reduced angiogenesis following injury. In human rotator cuff tendons, the expression of ANGPTL4 was correlated with the density of tendon endothelial cells. To our knowledge, this is the first study characterizing a role of ANGPTL4 in the tendon. ANGPTL4 may assist in the regulation of vascularity in the injured or mechanically loaded tendon. TGF-β and HIF-1α comprise two signalling pathways that modulate the expression of ANGPTL4 by mechanically stimulated tendon fibroblasts and, in the future, these could be manipulated to influence tendon healing or adaptation. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.
A summary risk score for the prediction of Alzheimer disease in elderly persons.
Reitz, Christiane; Tang, Ming-Xin; Schupf, Nicole; Manly, Jennifer J; Mayeux, Richard; Luchsinger, José A
2010-07-01
To develop a simple summary risk score for the prediction of Alzheimer disease in elderly persons based on their vascular risk profiles. A longitudinal, community-based study. New York, New York. Patients One thousand fifty-one Medicare recipients aged 65 years or older and residing in New York who were free of dementia or cognitive impairment at baseline. We separately explored the associations of several vascular risk factors with late-onset Alzheimer disease (LOAD) using Cox proportional hazards models to identify factors that would contribute to the risk score. Then we estimated the score values of each factor based on their beta coefficients and created the LOAD vascular risk score by summing these individual scores. Risk factors contributing to the risk score were age, sex, education, ethnicity, APOE epsilon4 genotype, history of diabetes, hypertension or smoking, high-density lipoprotein levels, and waist to hip ratio. The resulting risk score predicted dementia well. According to the vascular risk score quintiles, the risk to develop probable LOAD was 1.0 for persons with a score of 0 to 14 and increased 3.7-fold for persons with a score of 15 to 18, 3.6-fold for persons with a score of 19 to 22, 12.6-fold for persons with a score of 23 to 28, and 20.5-fold for persons with a score higher than 28. While additional studies in other populations are needed to validate and further develop the score, our study suggests that this vascular risk score could be a valuable tool to identify elderly individuals who might be at risk of LOAD. This risk score could be used to identify persons at risk of LOAD, but can also be used to adjust for confounders in epidemiologic studies.
Dutch monitor on stress and physical load: risk factors, consequences, and preventive action.
Houtman, I L; Goudswaard, A; Dhondt, S; van der Grinten, M P; Hildebrandt, V H; van der Poel, E G
1998-02-01
Due to recent changes in legislation on occupational health and safety, a national monitor on stress and physical load was developed in The Netherlands to monitor (a) risks and consequences of stress and physical load at work, (b) preventive actions in companies to reduce these risks, and (c) organisational and environmental variables that facilitate preventive actions. Information was gathered from employers, employees, and employees' representatives. The monitor was used with a nationally representative sample of companies in industry, wholesale trade, and banking and finance, 782 companies in total. The information from the employees, aggregated at the company level, was not found to be correlated with that from the employer from the same companies. Although many employers do recognise risk factors for both physical load and stress as a problem they often seem to underestimate the problem when compared with employees or their representatives. This is particularly the case for psychosocial risk factors. Also, the perception of outcome measures, especially employers who consider emotional exhaustion to be work related, were fewer than the employees' representatives of the same organisation. Preventive measures on physical load are much more popular than measures against stress. It is the responsibility of the employer to take more preventive action of all kinds. They need to recognise risk factors as problems and health outcomes to be related to work. Employees of larger companies should participate with employers to consider effective measures, and more use should be made of support at branch level. For specific preventive measures, specific predictors emerged. Except for measures to prevent work stress, information from employees did not sufficiently contribute to the initiation of preventive measures in the workplace.
1993-09-01
Different Size Transformers (Per Transformer ) 41 15 Additional Energy Losses for Mis-Sized Transformers (Per Transformer ) 42 16 Power System ...directly affects the amount of neutral line power loss in the system . Since most Army three-phase loads are distribution transformers spread out over a...61 Balancing Three-Phase Loads Balancing Feeder Circuit Loads Power Factor Correction Optimal Transformer Sizing Conductor Sizing Combined
Factors Controlling Sediment Load in The Central Anatolia Region of Turkey: Ankara River Basin.
Duru, Umit; Wohl, Ellen; Ahmadi, Mehdi
2017-05-01
Better understanding of the factors controlling sediment load at a catchment scale can facilitate estimation of soil erosion and sediment transport rates. The research summarized here enhances understanding of correlations between potential control variables on suspended sediment loads. The Soil and Water Assessment Tool was used to simulate flow and sediment at the Ankara River basin. Multivariable regression analysis and principal component analysis were then performed between sediment load and controlling variables. The physical variables were either directly derived from a Digital Elevation Model or from field maps or computed using established equations. Mean observed sediment rate is 6697 ton/year and mean sediment yield is 21 ton/y/km² from the gage. Soil and Water Assessment Tool satisfactorily simulated observed sediment load with Nash-Sutcliffe efficiency, relative error, and coefficient of determination (R²) values of 0.81, -1.55, and 0.93, respectively in the catchment. Therefore, parameter values from the physically based model were applied to the multivariable regression analysis as well as principal component analysis. The results indicate that stream flow, drainage area, and channel width explain most of the variability in sediment load among the catchments. The implications of the results, efficient siltation management practices in the catchment should be performed to stream flow, drainage area, and channel width.
Factors Controlling Sediment Load in The Central Anatolia Region of Turkey: Ankara River Basin
NASA Astrophysics Data System (ADS)
Duru, Umit; Wohl, Ellen; Ahmadi, Mehdi
2017-05-01
Better understanding of the factors controlling sediment load at a catchment scale can facilitate estimation of soil erosion and sediment transport rates. The research summarized here enhances understanding of correlations between potential control variables on suspended sediment loads. The Soil and Water Assessment Tool was used to simulate flow and sediment at the Ankara River basin. Multivariable regression analysis and principal component analysis were then performed between sediment load and controlling variables. The physical variables were either directly derived from a Digital Elevation Model or from field maps or computed using established equations. Mean observed sediment rate is 6697 ton/year and mean sediment yield is 21 ton/y/km² from the gage. Soil and Water Assessment Tool satisfactorily simulated observed sediment load with Nash-Sutcliffe efficiency, relative error, and coefficient of determination ( R²) values of 0.81, -1.55, and 0.93, respectively in the catchment. Therefore, parameter values from the physically based model were applied to the multivariable regression analysis as well as principal component analysis. The results indicate that stream flow, drainage area, and channel width explain most of the variability in sediment load among the catchments. The implications of the results, efficient siltation management practices in the catchment should be performed to stream flow, drainage area, and channel width.
Quantifying weight bearing while in passive standers and a comparison of standers.
Kecskemethy, Heidi H; Herman, Daniel; May, Ryan; Paul, Kathleen; Bachrach, Steven J; Henderson, Richard C
2008-07-01
Mechanical loading plays an important role in skeletal health, and this is a major reason standing devices are widely used with non-ambulatory persons. However, little is known about the true axial loading that occurs while in a stander, or the factors which may impact loading. The purpose of this study was to quantify weight borne while in a stander, and to directly compare different standers. Load measuring footplate adaptors were designed and fabricated specifically for this study. Weight bearing loads in 20 non-ambulatory persons with quadriplegic cerebral palsy aged 6 to 21 years (median 14 y) were continuously monitored during routine 30-minute standing sessions. Fourteen participants were female, six were male; one was Gross Motor Function Classification System (GMFCS) Level IV, and 19 were GMFCS Level V. Each participant was monitored on four to six occasions over an 8-week period, two to three times in each of two different standers (total 108 standing sessions). Weight bearing loads ranged widely from 37 to 101% of body weight. The difference between standers was as much as 29% body weight. There is wide variance in the actual weight borne while in passive standers. The type of stander utilized is one factor which can significantly affect the amount of weight borne.
Zhuang, Zhihao; Yoder, Bonita L; Burgers, Peter M J; Benkovic, Stephen J
2006-02-21
Numerous proteins that function in DNA metabolic pathways are known to interact with the proliferating cell nuclear antigen (PCNA). The important function of PCNA in stimulating various cellular activities requires its topological linkage with DNA. Loading of the circular PCNA onto duplex DNA requires the activity of a clamp-loader [replication factor C (RFC)] complex and the energy derived from ATP hydrolysis. The mechanistic and structural details regarding PCNA loading by the RFC complex are still developing. In particular, the positive identification of a long-hypothesized structure of an open clamp-RFC complex as an intermediate in loading has remained elusive. In this study, we capture an open yeast PCNA clamp in a complex with RFC through fluorescence energy transfer experiments. We also follow the topological transitions of PCNA in the various steps of the clamp-loading pathway through both steady-state and stopped-flow fluorescence studies. We find that ATP effectively drives the clamp-loading process to completion with the formation of the closed PCNA bound to DNA, whereas ATPgammaS cannot. The information derived from this work complements that obtained from previous structural and mechanistic studies and provides a more complete picture of a eukaryotic clamp-loading pathway using yeast as a paradigm.
Improved estimation of random vibration loads in launch vehicles
NASA Technical Reports Server (NTRS)
Mehta, R.; Erwin, E.; Suryanarayan, S.; Krishna, Murali M. R.
1993-01-01
Random vibration induced load is an important component of the total design load environment for payload and launch vehicle components and their support structures. The current approach to random vibration load estimation is based, particularly at the preliminary design stage, on the use of Miles' equation which assumes a single degree-of-freedom (DOF) system and white noise excitation. This paper examines the implications of the use of multi-DOF system models and response calculation based on numerical integration using the actual excitation spectra for random vibration load estimation. The analytical study presented considers a two-DOF system and brings out the effects of modal mass, damping and frequency ratios on the random vibration load factor. The results indicate that load estimates based on the Miles' equation can be significantly different from the more accurate estimates based on multi-DOF models.
Flight Speeds among Bird Species: Allometric and Phylogenetic Effects
Alerstam, Thomas; Rosén, Mikael; Bäckman, Johan; Ericson, Per G. P; Hellgren, Olof
2007-01-01
Flight speed is expected to increase with mass and wing loading among flying animals and aircraft for fundamental aerodynamic reasons. Assuming geometrical and dynamical similarity, cruising flight speed is predicted to vary as (body mass)1/6 and (wing loading)1/2 among bird species. To test these scaling rules and the general importance of mass and wing loading for bird flight speeds, we used tracking radar to measure flapping flight speeds of individuals or flocks of migrating birds visually identified to species as well as their altitude and winds at the altitudes where the birds were flying. Equivalent airspeeds (airspeeds corrected to sea level air density, U e) of 138 species, ranging 0.01–10 kg in mass, were analysed in relation to biometry and phylogeny. Scaling exponents in relation to mass and wing loading were significantly smaller than predicted (about 0.12 and 0.32, respectively, with similar results for analyses based on species and independent phylogenetic contrasts). These low scaling exponents may be the result of evolutionary restrictions on bird flight-speed range, counteracting too slow flight speeds among species with low wing loading and too fast speeds among species with high wing loading. This compression of speed range is partly attained through geometric differences, with aspect ratio showing a positive relationship with body mass and wing loading, but additional factors are required to fully explain the small scaling exponent of U e in relation to wing loading. Furthermore, mass and wing loading accounted for only a limited proportion of the variation in U e. Phylogeny was a powerful factor, in combination with wing loading, to account for the variation in U e. These results demonstrate that functional flight adaptations and constraints associated with different evolutionary lineages have an important influence on cruising flapping flight speed that goes beyond the general aerodynamic scaling effects of mass and wing loading. PMID:17645390
Thorstensen, Ketil; Kvitland, Mona A; Irgens, Wenche Ø; Åsberg, Arne; Borch-Iohnsen, Berit; Moen, Torolf; Hveem, Kristian
2017-11-01
Iron loading in p.C282Y homozygous HFE hemochromatosis subjects is highly variable, and it is unclear what factors cause this variability. Finding such factors could aid in predicting which patients are at highest risk and require closest follow-up. The degree of iron loading has previously been associated with certain HLA-types and with abnormally low CD8 + cell counts in peripheral blood. In 183 Norwegian, p.C282Y homozygotes (104 men, 79 women) originally found through population screening we determined HLA type and measured total T-lymphocytes, CD4 + and CD8 + cells, and compared this with data on iron loading. In p.C282Y homozygous men, but not in homozygous women, we found that the presence of two HLA-A*03 alleles increased the iron load on average by approximately 2-fold compared to p.C282Y homozygous men carrying zero or one A*03 allele. On the other hand, the presence of two HLA-A*01 alleles, in male subjects, apparently reduced the iron loading. In p.C282Y homozygous individuals, the iron loading was increased if the CD8 + cell number was below the 25 percentile or if the CD4 + cell number was above the 75 percentile. This effect appeared to be additive to the effect of the number of HLA-A*03 alleles. Our data indicate that homozygosity for the HLA-A*03 allele significantly increases the risk of excessive iron loading in Norwegian p.C282Y homozygous male patients. In addition, low CD8 + cell number or high CD4 + cell number further increases the risk of excessive iron loading.
Crucial parameter of the outcome in Crimean Congo hemorrhagic fever: Viral load.
Hasanoglu, Imran; Guner, Rahmet; Carhan, Ahmet; Kocak Tufan, Zeliha; Yagci-Caglayik, Dilek; Guven, Tumer; Yilmaz, Gul Ruhsar; Tasyaran, Mehmet A
2016-02-01
Crimean Congo hemorrhagic fever (CCHF) is a fatal disease with a mortality rate of 5-30%. CCHF can be asymptomatic or it may progress with bleeding and cause mortality. To evaluate relation of viral load with mortality, clinical and laboratory findings in CCHF. A total of 126 CCHF patients were included. Serum samples obtained from all patients on admission for measurement of viral load. In our study, mortality rate was 11.1%. The most important prognostic factor was viral load. Mean viral load was 8.3×10(7)copy/ml and 4.6×10(9)copy/ml in survived and dead patients, respectively (p<0.005). Probability of survival is found to be significantly reduced where AST >1130U/l, ALT >490U/l, CPK >505U/l, LDH >980U/l, platelet count <23×10(3)/l, creatinine >1.4mg/dl, INR >1.3, d-dimer >7100ng/dl, and viral load >1.03×10(8)copy/ml. Patients with 10(8)copy/ml or higher viral load had diarrhea, headache, unconsciousness, bleeding, and seizure significantly more frequently (p<0.05). WBC, hemoglobin, platelet counts were significantly lower whereas AST, ALT, CPK, LDH, creatinine levels, PT and aPTT time, d-dimer levels, and INR were found to be significantly higher in these group. There are several severity criteria for prognosis of CCHF. In addition to these parameters, we introduce creatinine as a predictive factor for prognosis. Our study, which has the largest number of patients among studies that evaluate viral load on CCHF shows that viral load is the most effective parameter on mortality. Copyright © 2015 Elsevier B.V. All rights reserved.
Fatigue analyses of the prototype Francis runners based on site measurements and simulations
NASA Astrophysics Data System (ADS)
Huang, X.; Chamberland-Lauzon, J.; Oram, C.; Klopfer, A.; Ruchonnet, N.
2014-03-01
With the increasing development of solar power and wind power which give an unstable output to the electrical grid, hydropower is required to give a rapid and flexible compensation, and the hydraulic turbines have to operate at off-design conditions frequently. Prototype Francis runners suffer from strong vibrations induced by high pressure pulsations at part load, low part load, speed-no-load and during start-stops and load rejections. Fatigue and damage may be caused by the alternating stress on the runner blades. Therefore, it becomes increasingly important to carry out fatigue analysis and life time assessment of the prototype Francis runners, especially at off-design conditions. This paper presents the fatigue analyses of the prototype Francis runners based on the strain gauge site measurements and numerical simulations. In the case of low part load, speed-no-load and transient events, since the Francis runners are subjected to complex hydraulic loading, which shows a stochastic characteristic, the rainflow counting method is used to obtain the number of cycles for various dynamic amplitude ranges. From middle load to full load, pressure pulsations caused by Rotor-stator- Interaction become the dominant hydraulic excitation of the runners. Forced response analysis is performed to calculate the maximum dynamic stress. The agreement between numerical and experimental stresses is evaluated using linear regression method. Taking into account the effect of the static stress on the S-N curve, the Miner's rule, a linear cumulative fatigue damage theory, is employed to calculate the damage factors of the prototype Francis runners at various operating conditions. The relative damage factors of the runners at different operating points are compared and discussed in detail.
Kamei, Hideya; Ito, Yoshinori; Kawada, Junichi; Ogiso, Satoshi; Onishi, Yasuharu; Komagome, Masahiko; Kurata, Nobuhiko; Ogura, Yasuhiro
2018-04-20
Serial monitoring of Epstein-Barr virus (EBV) reveals that certain pediatric liver transplant (LT) recipients exhibit high EBV loads for long periods. We investigated the incidence and risk factors of chronic high EBV (CHEBV) loads (continuous EBV DNA >10 000 IU/mL of whole blood for ≥6 months) and long-term outcomes. This single center, retrospective observational study investigated pediatric LT recipients who survived ≥6 months. We quantitated EBV DNA weekly during hospitalization and subsequently every 4 or 6 weeks at the outpatient clinic. Tacrolimus was maintained at a low trough level (<3 ng/mL, EBV DNA load >5000 IU/mL). Thirty-one of 77 LT recipients developed CHEBV. Univariate analysis revealed that age <2 years and body weight <10 kg upon LT, operation time <700 minutes, warm ischemia time (WIT) >35 minutes, graft-to-recipient weight ratio (GRWR) >2.7%, and preoperative EBV seronegativity were significantly associated with the development of CHEBV loads. Multivariate analysis identified significant associations of CHEBV with WIT >35 minutes, GRWR >2.7%, and preoperative seronegative. None of the recipients developed post-transplantation lymphoproliferative disorder. Survival rates of patients with and without CHEBV loads were not significantly different. A significant number of pediatric LT recipients developed CHEBV loads. Long WIT, high GRWR, and preoperative EBV seronegativity were significantly associated with the development of CHEBV loads. Although the long-term outcomes of patients with or without CHEBV loads were not significantly different, further studies of more subjects are warranted. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Atopy: a risk factor of refractory mycoplasma pneumoniae pneumonia?
Bao, Yi-Xiao; Li, Jing; Tian, Ye; Liu, Quang-Hua; Bao, Jun
2017-11-01
To investigate the relationship of pathogen DNA copies with clinic and laboratory features among children with Mycoplasma pneumoniae (MP) pneumonia. A total of 95 enrolled children with MP pneumonia were assigned into the high-MP-load group (>10 6 /mL) and the low-MP-load group (≤10 6 /mL) according to MP-DNA copies in bronchoalveolar lavage fluid (BALF). Clinical characteristics and any allergy history were collected. Aeroallergens and food allergens were detected with a skin test. Serum IgE and eosinophil cationic protein (ECP) were assessed using enzyme immunoassay. BALF levels of IL-4, IFN-γ, IL-8 and TNF-α were assessed by ELISA. Compared with the low-MP-load group, 72.7% in the high-MP-load group developed refractory MP pneumonia who failed to respond to at least 1-week treatment with macrolides (72.7% vs 41.9%, P = 0.005). More children in the high-load group than those in the low-load group presented with extrapulmonary manifestations, lung consolidation, pleural effusion and atopic conditions including any allergy history, positive findings of aeroallergen test and increased serum IgE and ECP (P < 0.05). A significant higher BALF IL-4 level was seen in the high-load group versus the low-load group (23.00 ± 11.24 vs 14.68 ± 7.12; pg/mL; P < 0.01). There were no significant differences in BALF levels of IFN-γ, IL-8 and TNF-α between the two groups (P > 0.05). Atopy may be a risk factor for the presence and severity of refractory MP pneumonia due to the high pathogen load in airway. © 2016 John Wiley & Sons Ltd.
Compliance measurements of chevron notched four point bend specimen
NASA Technical Reports Server (NTRS)
Calomino, Anthony; Bubsey, Raymond; Ghosn, Louis J.
1994-01-01
The experimental stress intensity factors for various chevron notched four point bend specimens are presented. The experimental compliance is verified using the analytical solution for a straight through crack four point bend specimen and the boundary integral equation method for one chevron geometry. Excellent agreement is obtained between the experimental and analytical results. In this report, stress intensity factors, loading displacements and crack mouth opening displacements are reported for different crack lengths and different chevron geometries, under four point bend loading condition.
Defining the market for gas cooling--
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brodrick, J.R.; Patel, R.
1990-01-01
This paper looks at the market prospects for emerging gas cooling technologies. Many factors are found influence market decisions, and a number of factors have been set aside for reasons of conservatism and expediency. By considering some of these motivators, a fuller understanding of the market is made. Relative to this information, the potential success of gas cooling systems are estimated. Three gas cooling systems are evaluated as possible approaches for base-loaded and peak-loaded commercial buildings. Other system concepts may be appropriate.
Experiments with Geometric Non-Linear Coupling for Analytical Validation
2010-03-01
maintaining a high safety factor. This is the primary constraint and is very important in keeping the end conditions of the experiment known. 3.1.4...the maximum load case while maintaining a safety factor of at least 2. Figure 3.14: Cable and Winch. The load is measured using a 3,000 lbf...the class and power of this laser, laser eyewear is required for safe use of the system. The Photon 80 can scan at various levels of detail. For
On Solutions for the Transient Response of Beams
NASA Technical Reports Server (NTRS)
Leonard, Robert W.
1959-01-01
Williams type modal solutions of the elementary and Timoshenko beam equations are presented for the response of several uniform beams to a general applied load. Example computations are shown for a free-free beam subject to various concentrated loads at its center. Discussion includes factors influencing the convergence of modal solutions and factors to be considered in a choice of beam theory. Results obtained by two numerical procedures, the traveling-wave method and Houbolt's method, are also presented and discussed.
Factor Rotation and Standard Errors in Exploratory Factor Analysis
ERIC Educational Resources Information Center
Zhang, Guangjian; Preacher, Kristopher J.
2015-01-01
In this article, we report a surprising phenomenon: Oblique CF-varimax and oblique CF-quartimax rotation produced similar point estimates for rotated factor loadings and factor correlations but different standard error estimates in an empirical example. Influences of factor rotation on asymptotic standard errors are investigated using a numerical…
Golay, Philippe; Reverte, Isabelle; Rossier, Jérôme; Favez, Nicolas; Lecerf, Thierry
2013-06-01
The interpretation of the Wechsler Intelligence Scale for Children--Fourth Edition (WISC-IV) is based on a 4-factor model, which is only partially compatible with the mainstream Cattell-Horn-Carroll (CHC) model of intelligence measurement. The structure of cognitive batteries is frequently analyzed via exploratory factor analysis and/or confirmatory factor analysis. With classical confirmatory factor analysis, almost all cross-loadings between latent variables and measures are fixed to zero in order to allow the model to be identified. However, inappropriate zero cross-loadings can contribute to poor model fit, distorted factors, and biased factor correlations; most important, they do not necessarily faithfully reflect theory. To deal with these methodological and theoretical limitations, we used a new statistical approach, Bayesian structural equation modeling (BSEM), among a sample of 249 French-speaking Swiss children (8-12 years). With BSEM, zero-fixed cross-loadings between latent variables and measures are replaced by approximate zeros, based on informative, small-variance priors. Results indicated that a direct hierarchical CHC-based model with 5 factors plus a general intelligence factor better represented the structure of the WISC-IV than did the 4-factor structure and the higher order models. Because a direct hierarchical CHC model was more adequate, it was concluded that the general factor should be considered as a breadth rather than a superordinate factor. Because it was possible for us to estimate the influence of each of the latent variables on the 15 subtest scores, BSEM allowed improvement of the understanding of the structure of intelligence tests and the clinical interpretation of the subtest scores. PsycINFO Database Record (c) 2013 APA, all rights reserved.
McNeer, Richard R; Bennett, Christopher L; Dudaryk, Roman
2016-02-01
Operating rooms are identified as being one of the noisiest of clinical environments, and intraoperative noise is associated with adverse effects on staff and patient safety. Simulation-based experiments would offer controllable and safe venues for investigating this noise problem. However, realistic simulation of the clinical auditory environment is rare in current simulators. Therefore, we retrofitted our operating room simulator to be able to produce immersive auditory simulations with the use of typical sound sources encountered during surgeries. Then, we tested the hypothesis that anesthesia residents would perceive greater task load and fatigue while being given simulated lunch breaks in noisy environments rather than in quiet ones. As a secondary objective, we proposed and tested the plausibility of a novel psychometric instrument for the assessment of stress. In this simulation-based, randomized, repeated-measures, crossover study, 2 validated psychometric survey instruments, the NASA Task Load Index (NASA-TLX), composed of 6 items, and the Swedish Occupational Fatigue Inventory (SOFI), composed of 5 items, were used to assess perceived task load and fatigue, respectively, in first-year anesthesia residents. Residents completed the psychometric instruments after being given lunch breaks in quiet and noisy intraoperative environments (soundscapes). The effects of soundscape grouping on the psychometric instruments and their comprising items were analyzed with a split-plot analysis. A model for a new psychometric instrument for measuring stress that combines the NASA-TLX and SOFI instruments was proposed, and a factor analysis was performed on the collected data to determine the model's plausibility. Twenty residents participated in this study. Multivariate analysis of variance showed an effect of soundscape grouping on the combined NASA-TLX and SOFI instrument items (P = 0.003) and the comparisons of univariate item reached significance for the NASA Temporal Demand item (P = 0.0004) and the SOFI Lack of Energy item (P = 0.001). Factor analysis extracted 4 factors, which were assigned the following construct names for model development: Psychological Task Load, Psychological Fatigue, Acute Physical Load, and Performance-Chronic Physical Load. Six of the 7 fit tests used in the partial confirmatory factor analysis were positive when we fitted the data to the proposed model, suggesting that further validation is warranted. This study provides evidence that noise during surgery can increase feelings of stress, as measured by perceived task load and fatigue levels, in anesthesiologists and adds to the growing literature pointing to an overall adverse impact of clinical noise on caregivers and patient safety. The psychometric model proposed in this study for assessing perceived stress is plausible based on factor analysis and will be useful for characterizing the impact of the clinical environment on subject stress levels in future investigations.
Schwellnus, Martin; Alonso, Juan-Manuel; Bahr, Roald; Clarsen, Ben; Dijkstra, H Paul; Gabbett, Tim J; Gleeson, Michael; Hutchinson, Mark R; Janse Van Rensburg, Christa; Meeusen, Romain; Orchard, John W; Pluim, Babette M; Raftery, Martin; Budgett, Richard; Engebretsen, Lars
2016-01-01
The modern-day athlete participating in elite sports is exposed to high training loads and increasingly saturated competition calendar. Emerging evidence indicates that inappropriate load management is a significant risk factor for acute illness and the overtraining syndrome. The IOC convened an expert group to review the scientific evidence for the relationship of load—including rapid changes in training and competition load, competition calendar congestion, psychological load and travel—and health outcomes in sport. This paper summarises the results linking load to risk of illness and overtraining in athletes, and provides athletes, coaches and support staff with practical guidelines for appropriate load management to reduce the risk of illness and overtraining in sport. These include guidelines for prescription of training and competition load, as well as for monitoring of training, competition and psychological load, athlete well-being and illness. In the process, urgent research priorities were identified. PMID:27535991
NASA Astrophysics Data System (ADS)
Zhe, MI; Jinfang, Zhang; Jun, Liu
2018-06-01
This paper presents the impacts of load, source and grid factors on renewable energy accommodation in the northern region of China. Renewable energy curtailment reasons and key measures to improve accommodations are also discussed. The production simulation method is utilized to analysis renewable energy accommodation and the Shapely value method is introduced to calculate the accommodation contribution rate of different factors. The result shows that the amount of renewable energy accommodation is 389 TWh in northern region of China by the year 2020. The contribution rate of load, source and grid factors to renewable energy accommodation are 39%, 35.8% and 25.1%, respectively.
Thermal expansion of composites: Methods and results. [large space structures
NASA Technical Reports Server (NTRS)
Bowles, D. E.; Tenney, D. R.
1981-01-01
The factors controlling the dimensional stability of various components of large space structures were investigated. Cyclic, thermal and mechanical loading were identified as the primary controlling factors of the dimensional stability of cables. For organic matrix composites, such as graphite-epoxy, it was found that these factors include moisture desorption in the space environment, thermal expansion as the structure moves from the sunlight to shadow in its orbit, mechanical loading, and microyielding of the material caused by microcracking of the matrix material. The major focus was placed on the thermal expansion of composites and in particular the development and testing of a method for its measurement.
Wu, Zhiwei; He, Hong S; Liu, Zhihua; Liang, Yu
2013-06-01
Fuel load is often used to prioritize stands for fuel reduction treatments. However, wildfire size and intensity are not only related to fuel loads but also to a wide range of other spatially related factors such as topography, weather and human activity. In prioritizing fuel reduction treatments, we propose using burn probability to account for the effects of spatially related factors that can affect wildfire size and intensity. Our burn probability incorporated fuel load, ignition probability, and spread probability (spatial controls to wildfire) at a particular location across a landscape. Our goal was to assess differences in reducing wildfire size and intensity using fuel-load and burn-probability based treatment prioritization approaches. Our study was conducted in a boreal forest in northeastern China. We derived a fuel load map from a stand map and a burn probability map based on historical fire records and potential wildfire spread pattern. The burn probability map was validated using historical records of burned patches. We then simulated 100 ignitions and six fuel reduction treatments to compare fire size and intensity under two approaches of fuel treatment prioritization. We calibrated and validated simulated wildfires against historical wildfire data. Our results showed that fuel reduction treatments based on burn probability were more effective at reducing simulated wildfire size, mean and maximum rate of spread, and mean fire intensity, but less effective at reducing maximum fire intensity across the burned landscape than treatments based on fuel load. Thus, contributions from both fuels and spatially related factors should be considered for each fuel reduction treatment. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Wasiuta, V. L.; Cooke, C. A.; Kirk, J.; Chambers, P. A.; Alexander, A. C.; Rooney, R. C.
2017-12-01
Rapid development of Oil Sands deposits in northern Alberta (Canada) raises concerns about human health and environmental impacts. We present results from a three-year study of winter-time atmospheric deposition of total mercury (THg) and methylmercury (MeHg) in six tributary watersheds of the Athabasca River. Seasonal snowpack THg and MeHg concentrations were obtained from spring-time sampling throughout the oil sands region. Winter-time Hg loads were then modeled at watershed and sub-basin scales using ArcGIS geostatistical kriging. To determine the potential impacts of snowmelt on aquatic ecosystems, six rivers were sampled at high frequency over 2012 to 2014 ice-free seasons. Hydrologic year (HY) and first discharge peak loads were then calculated from linear extrapolation of measured concentrations and mean daily discharge. Results showed high THg and MeHg loads from atmospheric deposition around regional upgrading facilities with loads diminishing outwards. This reflects the large proportion of particle bound Hg with a short atmospheric residence time, and deposition close to emission sources. Snowpacks within the six watersheds contained substantial proportions of tributary river THg and MeHg loads. For example, HY2014 snowpacks contained 24 to 46 % of river MeHg loads. All rivers showed a large proportion of HY loads discharged, within a few weeks, in the spring first discharge peak. HY2014 snowpack MeHg loads were greater than river loads in the first discharge peak for all watersheds except the High Hills. This first discharge peak is important as it occurs during critical growth periods for aquatic life. Large differences in tributary river THg and MeHg loads suggest factors other than atmospheric deposition and watershed scale contributed to the load. Considerably higher THg and MeHg snowpack loads in the Muskeg Watershed relative to river export suggest substantial losses to catchment soils or wetlands during snowmelt. Evaluation of factors that could contribute to the large differences in watershed Hg discharge, include proportion of wetlands along with different wetland classes, scale of industrial development, and development hydrologic connectivity. The consequence of long-term Hg loading to wetland ecosystems has yet to be assessed.
Brotons, Pedro; de Paz, Hector D; Toledo, Diana; Villanova, Marta; Plans, Pedro; Jordan, Iolanda; Dominguez, Angela; Jane, Mireia; Godoy, Pere; Muñoz-Almagro, Carmen
2016-04-01
To identify associations between nasopharyngeal Bordetella pertussis DNA load and clinical and epidemiological characteristics and evaluate DNA load prognostic value in pertussis severity. Prospective observational multi-centre study including nasopharyngeal samples positive to pertussis DNA by real-time PCR collected from children and adult patients in more than 200 health centres of Catalonia (Spain) during 2012-2013. B. pertussis load was inversely correlated with age (rho = -0.32, p < 0.001), time to diagnosis (rho = -0.33, p < 0.001) and number of symptoms (rho = 0.13, p = 0.002). Median bacterial load was significantly higher in inpatients versus outpatients (4.91 vs. 2.55 log10 CFU/mL, p < 0.001), patients with complications versus those without (6.05 vs. 2.82 log10 CFU/mL, p < 0.001), disease incidence in summer and autumn versus spring and winter (3.50 vs. 2.21 log10 CFU/mL, p = 0.002), and unvaccinated-partially vaccinated patients versus vaccinated (4.20 vs. 2.76 log10 CFU/mL, p = 0.004). A logistic regression model including bacterial load and other candidate prognostic factors showed good prediction for hospital care (AUC = 0.94) although only age and unvaccinated status were found to be prognostic factors. We observed strong positive associations of nasopharyngeal bacterial load with severity outcomes of hospitalisation and occurrence of complications. Bacterial load and other independent variables contributed to an accurate prognostic model for hospitalisation. Copyright © 2016 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Manorama, Abinand; Meyer, Ronald; Wiseman, Robert; Bush, Tamara Reid
2013-06-01
Forces applied to the skin cause a decrease in regional blood flow. This decrease in blood flow can cause tissue necrosis and lead to the formation of deep, penetrating wounds called pressure ulcers. These wounds are detrimental to individuals with compromised health, such as the elderly and spinal-cord injured. Although surface pressure is known to be a primary risk factor for developing a pressure ulcer, a seated individual rarely experiences pressure alone but rather combined loading which includes pressure as well as shear force on the skin. However, little research has been conducted to quantify the effects of shear forces on blood flow. Fifteen men were tested in a magnetic resonance imaging scanner under no load, a normal load, and a combination of normal and shear loads. Changes in arterial and venous blood flow in the forearm were measured using magnetic resonance angiography phase-contrast imaging. The blood flow in the anterior interosseous artery and basilic vein of the forearm decreased with the application of normal loads, and decreased further with the addition of shear loads. Marginal to significant differences at a 90% confidence level (P=0.08, 0.10) were observed, and medium to high effect sizes (0.3 to 0.5) were obtained. Based on these results, shear force is an important factor to consider in relation to pressure ulcer propagation and prevention, and hence, future prevention approaches should also focus on mitigating shear loads. Copyright © 2013 Elsevier Ltd. All rights reserved.
Rural population survey of behavioral and demographic risk factors for loaded firearms
Nordstrom, D; Zwerling, C; Stromquist, A; Burmeister, L; Merchant, J
2001-01-01
Objectives—In the United States, firearm deaths are almost as frequent as motor vehicle deaths. Firearm unintentional and suicide death rates are raised in rural areas. This study examines firearm prevalence and storage practices in three different types of rural households. Methods—Adults from a stratified random sample of 983 households in a rural Iowa county were interviewed. The χ2 test of independence was used to assess association between loaded, unlocked firearms and seven behavioral and demographic risk factors. Results—Nearly 67% of respondents reported firearms in their households. Nearly 7% of households had a loaded, unlocked gun. Prevalence of firearms at home was higher while prevalence of loaded, unlocked guns was lower than reported in other surveys. Prevalence of loaded, unlocked guns in farm households, 10.5%, was about twice the level in town households, 5.5% (χ2 test, p=0.033). Having taken a gun safety course was associated with more than double the prevalence of a loaded, unlocked gun, 13.5% v 5.1% (χ2 test, p=0.001). The prevalence of loaded, unlocked guns in households with a handgun, 19.3%, was four and one half times higher than in households with a long gun only, 4.2% (χ2 test, p=0.001). Households with someone with a lifetime prevalence of alcohol abuse or dependence were about twice as likely as other households, 13.0% v 6.6% (χ2 test, p=0.004), to report having loaded, unlocked firearms. Conclusions—Anyone interested in promoting safe storage of firearms in rural homes should consider these observations. PMID:11428557
Josephson, M; Pernold, G; Ahlberg-Hultén, G; Härenstam, A; Theorell, T; Vingård, E; Waldenström, M; Hjelm, E W
1999-01-01
This study investigated whether there is a relationship between high physical work load and adverse psychosocial work factors, and whether this relationship is different for women and men. Separate analyses for female registered nurses and assistant nurses were made because these are common occupations involving high physical and psychological demands. This study was part of the MUSIC-Norrtälje study, a population study with the overall aim of identifying risk factors for musculoskeletal disorders. The respondents, 1423 gainfully employed men and women, were randomly selected from the study population. The exposure assessments referred to a typical workday during the previous 12 months. Physical exposure was investigated by interview, psychosocial work factors by interview and questionnaire. For the women, but not the men, mainly routine work and a job strain situation, according to the model of Karasek and Theorell, increased the probability of having a high physical work load, assessed as a time-weighted average of energy expenditure in multiples of the resting metabolic rate. Results indicated that in female-dominated occupations, high physical work load might also imply adverse psychosocial conditions. A higher frequency of high physical work load and job strain was observed among assistant nurses compared with registered nurses. Covariance between physical and psychosocial demands makes it difficult to determine the relative influence of each in health problems. Results of the present study imply that this is a larger problem in studies of women than men.
Li, Zhonghua; Wang, Haiqin; Yang, Bo; Sun, Yukai; Huo, Ran
2015-12-01
The regeneration of functional skin remains elusive, due to poor engraftment, deficient vascularization, and excessive scar formation. Aiming to overcome these issues, the present study proposed the combination of a three-dimensional graphene foam (GF) scaffold loaded with bone marrow derived mesenchymal stem cells (MSCs) to improve skin wound healing. The GFs demonstrated good biocompatibility and promoted the growth and proliferation of MSCs. Meanwhile, the GFs loaded with MSCs obviously facilitated wound closure in animal model. The dermis formed in the presence of the GF structure loaded with MSCs was thicker and possessed a more complex structure at day 14 post-surgery. The transplanted MSCs correlated with upregulation of vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (bFGF), which may lead to neo-vascularization. Additionally, an anti-scarring effect was observed in the presence of the 3D-GF scaffold and MSCs, as evidenced by a downregulation of transforming growth factor-beta 1 (TGF-β1) and alpha-smooth muscle actin (α-SMA) together with an increase of TGF-β3. Altogether, the GF scaffold could guide the wound healing process with reduced scarring, and the MSCs were crucial to enhance vascularization and provided a better quality neo-skin. The GF scaffold loaded with MSCs possesses necessary bioactive cues to improve wound healing with reduced scarring, which may be of great clinical significance for skin wound healing. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Béjar, M.; Vericat, D.; Batalla, R. J.; Gibbins, C. N.
2018-06-01
The temporal and spatial variability of water and sediment loads of rivers is controlled by a suite of factors whose individual effects are often difficult to disentangle. While land use changes and localised human activities such as instream mining and hydropeaking alter water and sediment transfer, tributaries naturally contribute to discharge and sediment load of mainstem rivers, and so may help compensate upstream anthropogenic factors. The work presented here aimed to assess water and the sediment transfer in a river reach affected by gravel extraction and hydropeaking, set against a backdrop of changes to the supply of water and sediment from tributaries. Discharge and suspended sediment transport were monitored during two average hydrological years at three cross-sections along a 10-km reach of the upper River Cinca, in the Southern Pyrenees. Water and sediment loads differed substantially between the reaches. The upper reach showed a largely torrential discharge regime, controlled mainly by floods, and had high but variable water and sediment loads. The middle reach was influenced markedly by hydropeaking and tributary inflows, which increased its annual water yield four-fold. Suspended sediment load in this reach increased by only 25% compared to upstream, indicating that dilution predominated. In the lowermost section, while discharge remained largely unaltered, sediment load increased appreciably as a result of changes to sediment availability from instream mining and inputs from tributaries. At the reach scale, snowmelt and summer and autumn thunderstorms were responsible for most of the water yield, while flood flows determined the magnitude and transport of the sediment load. The study highlights that a combination of natural and human factors control the spatial and temporal transfer of water and sediment in river channels and that, depending on their geographic location and effect-size, can result in marked variability even over short downstream distances.
Tubiana, Roland; Le Chenadec, Jerome; Rouzioux, Christine; Mandelbrot, Laurent; Hamrene, Karima; Dollfus, Catherine; Faye, Albert; Delaugerre, Constance; Blanche, Stephane; Warszawski, Josiane
2010-02-15
The rate of mother-to-child transmission (MTCT) of human immunodeficiency virus (HIV) type 1 is as low as 0.5% in non-breast-feeding mothers who delivered at term while receiving antiretroviral therapy with a plasma viral load <500 copies/mL. This situation accounted for 20% of the infected children born during the period 1997-2006 in the French Perinatal Cohort. We aimed to identify factors associated with such residual transmission risk. We performed a case-control study nested in the aforementioned subpopulation of the French Perinatal Cohort. Nineteen case patients (transmitters) and 60 control subjects (nontransmitters) were included. Case patients and control subjects did not differ by geographical origin, gestational age at HIV diagnosis, type of antiretroviral therapy received, or elective Cesarean delivery. Case patients were less often receiving treatment at the time that they conceived pregnancy than control subjects (16% vs 45%; P=.017). A lower proportion of case patients had a viral load <500 copies/mL, compared with control subjects, at 14 weeks (0% vs 38.1%; P=.02), 28 weeks (7.7% vs 62.1%; P=.005), and 32 weeks: (21.4% vs 71.1%; P=.004). The difference remained significant when we restricted analysis to the 10 of 16 intrapartum transmission cases. In a multivariate analysis at 30+/-4 weeks adjusted for viral load, CD4(+) T cell count, and time at antiretroviral therapy initiation, viral load was the only factor independently associated with MTCT of HIV (adjusted odds ratio, 23.2; 95% confidence interval, 3.5-553; P<.001). Early and sustained control of viral load is associated with a decreasing residual risk of MTCT of HIV-1. Guidelines should take into account not only CD4(+) T cell count and risk of preterm delivery, but also baseline HIV-1 load for deciding when to start antiretroviral therapy during pregnancy.
Higher and Lower Order Factor Analyses of the Temperament in Middle Childhood Questionnaire.
Kotelnikova, Yuliya; Olino, Thomas M; Klein, Daniel N; Mackrell, Sarah V M; Hayden, Elizabeth P
2017-12-01
The Temperament in Middle Childhood Questionnaire (TMCQ) is a widely used parent-report measure of temperament. However, neither its lower nor higher order structures has been tested via a bottom-up, empirically based approach. We conducted higher and lower order exploratory factor analyses (EFAs) of the TMCQ in a large ( N = 654) sample of 9-year-olds. Item-level EFAs identified 92 items as suitable (i.e., with loadings ≥.40) for constructing lower order factors, only half of which resembled a TMCQ scale posited by the measure's authors. Higher order EFAs of the lower order factors showed that a three-factor structure (Impulsivity/Negative Affectivity, Negative Affectivity, and Openness/Assertiveness) was the only admissible solution. Overall, many TMCQ items did not load well onto a lower order factor. In addition, only three factors, which did not show a clear resemblance to Rothbart's four-factor model of temperament in middle childhood, were needed to account for the higher order structure of the TMCQ.
Higher- and Lower-Order Factor Analyses of the Temperament in Middle Childhood Questionnaire
Kotelnikova, Yuliya; Olino, Thomas M.; Klein, Daniel N.; Mackrell, Sarah V.M.; Hayden, Elizabeth P.
2017-01-01
The Temperament in Middle Childhood Questionnaire (TMCQ; Simonds & Rothbart, 2004) is a widely used parent-report measure of temperament. However, neither its lower- nor higher-order structures have been tested via a bottom-up, empirically based approach. We conducted higher- and lower-order exploratory factor analyses (EFAs) of the TMCQ in a large (N = 654) sample of 9-year-olds. Item-level EFAs identified 92 items as suitable (i.e., with loadings ≥.40) for constructing lower-order factors, only half of which resembled a TMCQ scale posited by the measure’s authors. Higher-order EFAs of the lower-order factors showed that a three-factor structure (Impulsivity/Negative Affectivity, Negative Affectivity, and Openness/Assertiveness) was the only admissible solution. Overall, many TMCQ items did not load well onto a lower-order factor. In addition, only three factors, which did not show a clear resemblance to Rothbart’s four-factor model of temperament in middle childhood, were needed to account for the higher-order structure of the TMCQ. PMID:27002124
Tan, Eng-lai; Selvaratnam, G; Kananathan, R; Sam, Choon-kook
2006-09-24
Nasopharyngeal carcinoma (NPC) is a common epithelial neoplasm among the Chinese populations in Southern China and South East Asia. Epstein-Barr virus (EBV) is known to be an important etiologic agent of NPC and the viral gene products are frequently detected in NPC tissues along with elevated antibody titres to the viral proteins (VCA and EA) in a majority of patients. Elevated plasma EBV DNA load is regarded as an important marker for the presence of the disease and for the monitoring of disease progression. However, other serum/plasma parameters such as the levels of certain interleukins and growth factors have also been implicated in NPC. The objectives of the present study are, 1) to investigate the correlations between plasma EBV DNA load and the levels of interleukin (IL)-6, IL-10, TGF-beta1 and SCF (steel factor) and 2) to relate these parameters to the stages of NPC and the effect of treatment. A total of 78 untreated NPC patients were enrolled in this study. Of these, 51 were followed-up after treatment. The remaining patients had irregular or were lost to follow-up. Plasma EBV DNA was quantified using real-time quantitative PCR. The levels of plasma interleukins and growth factors were quantified using ELISA. A significant decrease in EBV DNA load was detected in plasma of untreated NPC patients (1669 +/- 637 copies/mL; n = 51) following treatment (57 +/- 37 copies/mL, p < 0.05); n = 51). Plasma EBV DNA load was shown to be a good prognosticator for disease progression and clinical outcome in five of the follow-up patients. A significant difference in IL-6 levels was noted between the untreated patients (164 +/- 37 pg/mL; n = 51) and following treatment (58 +/- 16 pg/mL, p < 0.05; n = 51). Positive correlations between EBV DNA load and IL-10 (r(49) = 0.535, p < 0.01), between IL6 and IL-10 (r(49) = 0.474, p < 0.01) and between TGF and SCF (r(49) = 0.464, p < 0.01) were observed in patients following treatment. None of the parameters tested including IgA-VCA were associated with tumour stages. We conclude that among the parameters investigated, EBV DNA load and IL-6 levels were promising markers for the presence of NPC and for the assessment of treatment outcome.
DOT National Transportation Integrated Search
2007-01-01
The Commonwealth of Virginia is currently transitioning from the long-used AASHTO Allowable Stress Design (ASD) specification to AASHTO's Load and Resistance Factor Design (LRFD) specification. The new specification features revised live loads, more ...
Fatigue Resistant Design Criteria for MD SHA Cantilevered Mast Arm Signal Structure
DOT National Transportation Integrated Search
2017-12-01
The fatigue design of the mast arm structures and connections vary significantly based on the Category of Importance factor adopted and the load cases for fatigue design loads. Consideration should include the cost and size of the structures for both...
DOT National Transportation Integrated Search
2015-06-01
The Load and Resistance Factor Design (LRFD) method has evolved to become a : more reliable approach to bridge design in the past century. Nevertheless, safety is : always the number one concern in the design of bridge structures. Equally important, ...
Empirical determination of nutrient loading thresholds that negatively impact seagrass communities have been elusive due to the multitude of factors involved. Using a mesocosm system that simulated Pacific Northwest estuaries, we evaluated macrophyte metrics across gradients of ...
14 CFR 27.493 - Braked roll conditions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... vertical load must be based on a load factor of at least— (1) 1.33, for the attitude specified in § 27.479(a)(1); and (2) 1.0 for the attitude specified in § 27.479(a)(2); and (b) The structure must be...
14 CFR 29.493 - Braked roll conditions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... vertical load must be based on a load factor of at least— (1) 1.33, for the attitude specified in § 29.479(a)(1); and (2) 1.0, for the attitude specified in § 29.479(a)(2); and (b) The structure must be...
Analysis of surface cracks in finite plates under tension or bending loads
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.; Raju, I. S.
1979-01-01
Stress-intensity factors calculated with a three-dimensional, finite-element analysis for shallow and deep semielliptical surface cracks in finite elastic isotropic plates subjected to tension or bending loads are presented. A wide range of configuration parameters was investigated. The ratio of crack depth to plate thickness ranged from 0.2 to 0.8 and the ratio of crack depth to crack length ranged from 0.2 to 2.0. The effects of plate width on stress-intensity variations along the crack front was also investigated. A wide-range equation for stress-intensity factors along the crack front as a function of crack depth, crack length, plate thickness, and plate width was developed for tension and bending loads. The equation was used to predict patterns of surface-crack growth under tension or bending fatigue loads. A modified form of the equation was also used to correlate surface-crack fracture data for a brittle epoxy material within + or - 10 percent for a wide range of crack shapes and crack sizes.
Mayton, Alan G.; Jobes, Christopher C.; Gallagher, Sean
2015-01-01
To further assess vibration exposure on haul trucks (HTs) and front-end wheel loaders (FELs), follow-up investigations were conducted at two US crushed stone operations. The purpose was to: 1) evaluate factors such as load/no-load conditions, speed, load capacity, vehicle age, and seat transmissibility relative to vibration exposure; 2) compare exposure levels with existing ISO/ANSI and EUGPG guidelines. Increasing HT speed increased recorded vibration at the chassis and seat as expected. Neither vehicle load nor vehicle speed increased transmissibility. Increasing HT size and age did show transmissibility decreasing. HT dominant-axis wRMS levels (most often the y-axis, lateral or side-to-side direction) were predominantly within the health guidance caution zone (HGCZ). However, several instances showed vibration dose value (VDV) above the exposure limit value (ELV) for the ISO/ANSI guidelines. VDV levels (all dominant x-axis or fore-aft) were within and above the HGCZ for the EUGPG and above the HGCZ for ISO/ANSI guidelines. PMID:26361493
Numerical investigation of contact stresses for fretting fatigue damage initiation
NASA Astrophysics Data System (ADS)
Bhatti, N. A.; Abdel Wahab, M.
2017-05-01
Fretting fatigue phenomena occurs due to interaction between contacting bodies under application of cyclic and normal loads. In addition to environmental conditions and material properties, the response at the contact interface highly depends on the combination of applied loads. High stress concentration is present at the contact interface, which can start the damage nucleation process. At the culmination of nucleation process several micro cracks are initiated, ultimately leading to the structural failure. In this study, effect of ratio of tangential to normal load on contact stresses, slip amplitude and damage initiation is studied using finite element analysis. The results are evaluated for Ruiz parameter as it involves the slip amplitude which in an important factor in fretting fatigue conditions. It is observed that tangential to normal load ratio influences the stick zone size and damage initiation life. Furthermore, it is observed that tensile stress is the most important factor that drives the damage initiation to failure for the cases where failure occurs predominantly in mode I manner.