Precise determination of time to reach viral load set point after acute HIV-1 infection.
Huang, Xiaojie; Chen, Hui; Li, Wei; Li, Haiying; Jin, Xia; Perelson, Alan S; Fox, Zoe; Zhang, Tong; Xu, Xiaoning; Wu, Hao
2012-12-01
The HIV viral load set point has long been used as a prognostic marker of disease progression and more recently as an end-point parameter in HIV vaccine clinical trials. The definition of set point, however, is variable. Moreover, the earliest time at which the set point is reached after the onset of infection has never been clearly defined. In this study, we obtained sequential plasma viral load data from 60 acutely HIV-infected Chinese patients among a cohort of men who have sex with men, mathematically determined viral load set point levels, and estimated time to attain set point after infection. We also compared the results derived from our models and that obtained from an empirical method. With novel uncomplicated mathematic model, we discovered that set points may vary from 21 to 119 days dependent on the patients' initial viral load trajectory. The viral load set points were 4.28 ± 0.86 and 4.25 ± 0.87 log10 copies per milliliter (P = 0.08), respectively, as determined by our model and an empirical method, suggesting an excellent agreement between the old and new methods. We provide a novel method to estimate viral load set point at the very early stage of HIV infection. Application of this model can accurately and reliably determine the set point, thus providing a new tool for physicians to better monitor early intervention strategies in acutely infected patients and scientists to rationally design preventative vaccine studies.
NASA Astrophysics Data System (ADS)
van Vonno, N. W.; White, J. D.; Pearce, L. G.; Thomson, E. J.; Gill, J. S.; Mansilla, O. E.
2014-08-01
Single-event transient (SET) phenomena in power management applications has evolved into a key issue, particularly in point of load (POL) buck regulators, as the loads driven by these devices are sensitive to even short-term overvoltage conditions. We preface this paper by a discussion of earlier destructive and nondestructive SEE testing of Intersil integrated point of load regulators, with emphasis on SET phenomena and some of the lessons learned in this work. We then report recent results of SET and destructive SEE testing of the ISL70003SEH POL converter, together with a brief discussion of the part's electrical and radiation hardness specifications. We conclude with a brief overview of low and high dose rate total dose testing of the part.
A comparison of methods for determining HIV viral set point.
Mei, Y; Wang, L; Holte, S E
2008-01-15
During a course of human immunodeficiency virus (HIV-1) infection, the viral load usually increases sharply to a peak following infection and then drops rapidly to a steady state, where it remains until progression to AIDS. This steady state is often referred to as the viral set point. It is believed that the HIV viral set point results from an equilibrium between the HIV virus and immune response and is an important indicator of AIDS disease progression. In this paper, we analyze a real data set of viral loads measured before antiretroviral therapy is initiated, and propose two-phase regression models to utilize all available data to estimate the viral set point. The advantages of the proposed methods are illustrated by comparing them with two empirical methods, and the reason behind the improvement is also studied. Our results illustrate that for our data set, the viral load data are highly correlated and it is cost effective to estimate the viral set point based on one or two measurements obtained between 5 and 12 months after HIV infection. The utility and limitations of this recommendation will be discussed. Copyright (c) 2007 John Wiley & Sons, Ltd.
Viral genetic variation accounts for a third of variability in HIV-1 set-point viral load in Europe.
Blanquart, François; Wymant, Chris; Cornelissen, Marion; Gall, Astrid; Bakker, Margreet; Bezemer, Daniela; Hall, Matthew; Hillebregt, Mariska; Ong, Swee Hoe; Albert, Jan; Bannert, Norbert; Fellay, Jacques; Fransen, Katrien; Gourlay, Annabelle J; Grabowski, M Kate; Gunsenheimer-Bartmeyer, Barbara; Günthard, Huldrych F; Kivelä, Pia; Kouyos, Roger; Laeyendecker, Oliver; Liitsola, Kirsi; Meyer, Laurence; Porter, Kholoud; Ristola, Matti; van Sighem, Ard; Vanham, Guido; Berkhout, Ben; Kellam, Paul; Reiss, Peter; Fraser, Christophe
2017-06-01
HIV-1 set-point viral load-the approximately stable value of viraemia in the first years of chronic infection-is a strong predictor of clinical outcome and is highly variable across infected individuals. To better understand HIV-1 pathogenesis and the evolution of the viral population, we must quantify the heritability of set-point viral load, which is the fraction of variation in this phenotype attributable to viral genetic variation. However, current estimates of heritability vary widely, from 6% to 59%. Here we used a dataset of 2,028 seroconverters infected between 1985 and 2013 from 5 European countries (Belgium, Switzerland, France, the Netherlands and the United Kingdom) and estimated the heritability of set-point viral load at 31% (CI 15%-43%). Specifically, heritability was measured using models of character evolution describing how viral load evolves on the phylogeny of whole-genome viral sequences. In contrast to previous studies, (i) we measured viral loads using standardized assays on a sample collected in a strict time window of 6 to 24 months after infection, from which the viral genome was also sequenced; (ii) we compared 2 models of character evolution, the classical "Brownian motion" model and another model ("Ornstein-Uhlenbeck") that includes stabilising selection on viral load; (iii) we controlled for covariates, including age and sex, which may inflate estimates of heritability; and (iv) we developed a goodness of fit test based on the correlation of viral loads in cherries of the phylogenetic tree, showing that both models of character evolution fit the data well. An overall heritability of 31% (CI 15%-43%) is consistent with other studies based on regression of viral load in donor-recipient pairs. Thus, about a third of variation in HIV-1 virulence is attributable to viral genetic variation.
Examining HIV Viral Load in a Matched Cohort of HIV Positive Individuals With and Without Psoriasis.
Wu, Jashin J; Gilbert, Kathleen E; Batech, Michael; Manalo, Iviensan F; Towner, William J; Raposo, Rui André Saraiva; Nixon, Douglas F; Liao, Wilson
2017-04-01
BACKGROUND: HIV-associated psoriasis is well-documented. Genetic, cellular, and cytokine profiles have been used as evidence to suggest psoriasis activates antiviral pathways. There has been a lack of epidemiologic evidence investigating whether psoriasis patients have lower HIV viral counts compared to non-psoriasis patients.
OBJECTIVE: Compare the viral load set point of HIV positive patients with and without psoriasis.
METHODS: A retrospective matched cohort study of HIV positive patients with and without psoriasis using the Kaiser Permanente Southern California Health Plan database.
RESULTS: We identified 101 HIV-positive psoriasis cases; 19 met inclusion criteria and were matched with 3-5 control patients; 94 total patients were analyzed. The mean age was 41.4 (12.07) years and 83% were male. Overall, the median log of the viral load of cases was slightly higher than controls (4.3 vs 4.2; P less than 0.01).
CONCLUSIONS: The serum viral load set point of patients with HIV and psoriasis was slightly higher than the viral load set point of HIV patients without psoriasis.
J Drugs Dermatol. 2017;16(4):372-377.
.Viral genetic variation accounts for a third of variability in HIV-1 set-point viral load in Europe
Wymant, Chris; Cornelissen, Marion; Gall, Astrid; Bakker, Margreet; Bezemer, Daniela; Hall, Matthew; Hillebregt, Mariska; Ong, Swee Hoe; Albert, Jan; Bannert, Norbert; Fellay, Jacques; Fransen, Katrien; Gourlay, Annabelle J.; Grabowski, M. Kate; Gunsenheimer-Bartmeyer, Barbara; Günthard, Huldrych F.; Kivelä, Pia; Kouyos, Roger; Laeyendecker, Oliver; Liitsola, Kirsi; Meyer, Laurence; Porter, Kholoud; Ristola, Matti; van Sighem, Ard; Vanham, Guido; Berkhout, Ben; Kellam, Paul; Reiss, Peter; Fraser, Christophe
2017-01-01
HIV-1 set-point viral load—the approximately stable value of viraemia in the first years of chronic infection—is a strong predictor of clinical outcome and is highly variable across infected individuals. To better understand HIV-1 pathogenesis and the evolution of the viral population, we must quantify the heritability of set-point viral load, which is the fraction of variation in this phenotype attributable to viral genetic variation. However, current estimates of heritability vary widely, from 6% to 59%. Here we used a dataset of 2,028 seroconverters infected between 1985 and 2013 from 5 European countries (Belgium, Switzerland, France, the Netherlands and the United Kingdom) and estimated the heritability of set-point viral load at 31% (CI 15%–43%). Specifically, heritability was measured using models of character evolution describing how viral load evolves on the phylogeny of whole-genome viral sequences. In contrast to previous studies, (i) we measured viral loads using standardized assays on a sample collected in a strict time window of 6 to 24 months after infection, from which the viral genome was also sequenced; (ii) we compared 2 models of character evolution, the classical “Brownian motion” model and another model (“Ornstein–Uhlenbeck”) that includes stabilising selection on viral load; (iii) we controlled for covariates, including age and sex, which may inflate estimates of heritability; and (iv) we developed a goodness of fit test based on the correlation of viral loads in cherries of the phylogenetic tree, showing that both models of character evolution fit the data well. An overall heritability of 31% (CI 15%–43%) is consistent with other studies based on regression of viral load in donor–recipient pairs. Thus, about a third of variation in HIV-1 virulence is attributable to viral genetic variation. PMID:28604782
Parametric analysis of parameters for electrical-load forecasting using artificial neural networks
NASA Astrophysics Data System (ADS)
Gerber, William J.; Gonzalez, Avelino J.; Georgiopoulos, Michael
1997-04-01
Accurate total system electrical load forecasting is a necessary part of resource management for power generation companies. The better the hourly load forecast, the more closely the power generation assets of the company can be configured to minimize the cost. Automating this process is a profitable goal and neural networks should provide an excellent means of doing the automation. However, prior to developing such a system, the optimal set of input parameters must be determined. The approach of this research was to determine what those inputs should be through a parametric study of potentially good inputs. Input parameters tested were ambient temperature, total electrical load, the day of the week, humidity, dew point temperature, daylight savings time, length of daylight, season, forecast light index and forecast wind velocity. For testing, a limited number of temperatures and total electrical loads were used as a basic reference input parameter set. Most parameters showed some forecasting improvement when added individually to the basic parameter set. Significantly, major improvements were exhibited with the day of the week, dew point temperatures, additional temperatures and loads, forecast light index and forecast wind velocity.
Bandholm, Thomas; Thorborg, Kristian; Lunn, Troels Haxholdt; Kehlet, Henrik; Jakobsen, Thomas Linding
2014-01-01
Background Loading and contraction failure (muscular exhaustion) are strength training variables known to influence neural activation of the exercising muscle in healthy subjects, which may help reduce neural inhibition of the quadriceps muscle following total knee arthroplasty (TKA). It is unknown how these exercise variables influence knee pain after TKA. Objective To investigate the effect of loading and contraction failure on knee pain during strength training, shortly following TKA. Design Cross-sectional study. Setting Consecutive sample of patients from the Copenhagen area, Denmark, receiving a TKA, between November 2012 and April 2013. Participants Seventeen patients, no more than 3 weeks after their TKA. Main outcome measures: In a randomized order, the patients performed 1 set of 4 standardized knee extensions, using relative loads of 8, 14, and 20 repetition maximum (RM), and ended with 1 single set to contraction failure (14 RM load). The individual loadings (kilograms) were determined during a familiarization session >72 hours prior. The patients rated their knee pain during each repetition, using a numerical rating scale (0–10). Results Two patients were lost to follow up. Knee pain increased with increasing load (20 RM: 3.1±2.0 points, 14 RM: 3.5±1.8 points, 8 RM: 4.3±2.5 points, P = 0.006), and repetitions to contraction failure (10% failure: 3.2±1.9 points, 100% failure: 5.4±1.6 points, P<0.001). Resting knee pain 60 seconds after the final repetition (2.7±2.4 points) was not different from that recorded before strength training (2.7±1.8 points, P = 0.88). Conclusion Both loading and repetitions performed to contraction failure during knee- extension strength-training, increased post-operative knee pain during strength training implemented shortly following TKA. However, only the increase in pain during repetitions to contraction failure exceeded that defined as clinically relevant, and was very short-lived. Trial Registration ClinicalTrials.gov NCT01729520 PMID:24614574
Indirect addressing and load balancing for faster solution to Mandelbrot Set on SIMD architectures
NASA Technical Reports Server (NTRS)
Tomboulian, Sherryl
1989-01-01
SIMD computers with local indirect addressing allow programs to have queues and buffers, making certain kinds of problems much more efficient. Examined here are a class of problems characterized by computations on data points where the computation is identical, but the convergence rate is data dependent. Normally, in this situation, the algorithm time is governed by the maximum number of iterations required by each point. Using indirect addressing allows a processor to proceed to the next data point when it is done, reducing the overall number of iterations required to approach the mean convergence rate when a sufficiently large problem set is solved. Load balancing techniques can be applied for additional performance improvement. Simulations of this technique applied to solving Mandelbrot Sets indicate significant performance gains.
Increased Coal Plant Flexibility Can Improve Renewables Integration |
practices that enable lower turndowns, faster starts and stops, and faster ramping between load set-points faster ramp rates and faster and less expensive starts. Flexible Load - Demand Response Resources Demand response (DR) is a load management practice of deliberately reducing or adding load to balance the system
Janes, Holly; Herbeck, Joshua T; Tovanabutra, Sodsai; Thomas, Rasmi; Frahm, Nicole; Duerr, Ann; Hural, John; Corey, Lawrence; Self, Steve G; Buchbinder, Susan P; McElrath, M Juliana; O'Connell, Robert J; Paris, Robert M; Rerks-Ngarm, Supachai; Nitayaphan, Sorachai; Pitisuttihum, Punnee; Kaewkungwal, Jaranit; Robb, Merlin L; Michael, Nelson L; Mullins, James I; Kim, Jerome H; Gilbert, Peter B; Rolland, Morgane
2015-10-01
Given the variation in the HIV-1 viral load (VL) set point across subjects, as opposed to a fairly stable VL over time within an infected individual, it is important to identify the characteristics of the host and virus that affect VL set point. Although recently infected individuals with multiple phylogenetically linked HIV-1 founder variants represent a minority of HIV-1 infections, we found--n two different cohorts--hat more diverse HIV-1 populations in early infection were associated with significantly higher VL 1 year after HIV-1 diagnosis.
Bertels, Frederic; Marzel, Alex; Leventhal, Gabriel; Mitov, Venelin; Fellay, Jacques; Günthard, Huldrych F; Böni, Jürg; Yerly, Sabine; Klimkait, Thomas; Aubert, Vincent; Battegay, Manuel; Rauch, Andri; Cavassini, Matthias; Calmy, Alexandra; Bernasconi, Enos; Schmid, Patrick; Scherrer, Alexandra U; Müller, Viktor; Bonhoeffer, Sebastian; Kouyos, Roger; Regoes, Roland R
2018-01-01
Pathogen strains may differ in virulence because they attain different loads in their hosts, or because they induce different disease-causing mechanisms independent of their load. In evolutionary ecology, the latter is referred to as "per-parasite pathogenicity". Using viral load and CD4+ T-cell measures from 2014 HIV-1 subtype B-infected individuals enrolled in the Swiss HIV Cohort Study, we investigated if virulence-measured as the rate of decline of CD4+ T cells-and per-parasite pathogenicity are heritable from donor to recipient. We estimated heritability by donor-recipient regressions applied to 196 previously identified transmission pairs, and by phylogenetic mixed models applied to a phylogenetic tree inferred from HIV pol sequences. Regressing the CD4+ T-cell declines and per-parasite pathogenicities of the transmission pairs did not yield heritability estimates significantly different from zero. With the phylogenetic mixed model, however, our best estimate for the heritability of the CD4+ T-cell decline is 17% (5-30%), and that of the per-parasite pathogenicity is 17% (4-29%). Further, we confirm that the set-point viral load is heritable, and estimate a heritability of 29% (12-46%). Interestingly, the pattern of evolution of all these traits differs significantly from neutrality, and is most consistent with stabilizing selection for the set-point viral load, and with directional selection for the CD4+ T-cell decline and the per-parasite pathogenicity. Our analysis shows that the viral genotype affects virulence mainly by modulating the per-parasite pathogenicity, while the indirect effect via the set-point viral load is minor. © The Author 2017. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.
Bertels, Frederic; Marzel, Alex; Leventhal, Gabriel; Mitov, Venelin; Fellay, Jacques; Günthard, Huldrych F; Böni, Jürg; Yerly, Sabine; Klimkait, Thomas; Aubert, Vincent; Battegay, Manuel; Rauch, Andri; Cavassini, Matthias; Calmy, Alexandra; Bernasconi, Enos; Schmid, Patrick; Scherrer, Alexandra U; Müller, Viktor; Bonhoeffer, Sebastian; Kouyos, Roger; Regoes, Roland R
2018-01-01
Abstract Pathogen strains may differ in virulence because they attain different loads in their hosts, or because they induce different disease-causing mechanisms independent of their load. In evolutionary ecology, the latter is referred to as “per-parasite pathogenicity”. Using viral load and CD4+ T-cell measures from 2014 HIV-1 subtype B-infected individuals enrolled in the Swiss HIV Cohort Study, we investigated if virulence—measured as the rate of decline of CD4+ T cells—and per-parasite pathogenicity are heritable from donor to recipient. We estimated heritability by donor–recipient regressions applied to 196 previously identified transmission pairs, and by phylogenetic mixed models applied to a phylogenetic tree inferred from HIV pol sequences. Regressing the CD4+ T-cell declines and per-parasite pathogenicities of the transmission pairs did not yield heritability estimates significantly different from zero. With the phylogenetic mixed model, however, our best estimate for the heritability of the CD4+ T-cell decline is 17% (5–30%), and that of the per-parasite pathogenicity is 17% (4–29%). Further, we confirm that the set-point viral load is heritable, and estimate a heritability of 29% (12–46%). Interestingly, the pattern of evolution of all these traits differs significantly from neutrality, and is most consistent with stabilizing selection for the set-point viral load, and with directional selection for the CD4+ T-cell decline and the per-parasite pathogenicity. Our analysis shows that the viral genotype affects virulence mainly by modulating the per-parasite pathogenicity, while the indirect effect via the set-point viral load is minor. PMID:29029206
Sullivan, Patrick S.; Fideli, Ulgen; Wall, Kristin M.; Chomba, Elwyn; Vwalika, Cheswa; Kilembe, William; Tichacek, Amanda; Luisi, Nicole; Mulenga, Joseph; Hunter, Eric; Boeras, Debrah; Allen, Susan
2013-01-01
Objective To describe symptoms, physical exam findings, and set point viral load associated with acute HIV seroconversion in a heterosexual cohort of discordant couples in Zambia. Design We followed HIV serodiscordant couples in Lusaka, Zambia from 1995–2009 with HIV testing of negative partners and symptom inventories 3-monthly, and physical examinations annually. Methods We compared prevalence of self-reported or treated symptoms (malaria syndrome, chronic diarrhea, asthenia, night sweats, and oral candidiasis) and annual physical exam [PE] findings (unilateral or bilateral neck, axillary, or inguinal adenopathy; and dermatosis) in seroconverting versus HIV-negative or HIV-positive intervals, controlling for repeated observations, age, and sex. A composite score comprised of significant symptoms and PE findings predictive of seroconversion versus HIV-negative intervals was constructed. We modeled the relationship between number of symptoms and PE findings at seroconversion and log set-point viral load [VL] using linear regression. Results 2,388 HIV-negative partners were followed for a median of 18 months; 429 seroconversions occurred. Neither symptoms nor PE findings were reported for most seroconverters. Seroconversion was significantly associated with malaria syndrome among non-diarrheic patients (adjusted odds ratio [aOR]=4.0) night sweats (aOR=1.4), and bilateral axillary (aOR = 1.6), inguinal (aOR=2.2), and neck (aOR=2.2) adenopathy relative to HIV-negative intervals. Median number of symptoms was positively associated with set-point VL (p<0.001). Conclusions Though most acute and early infections were asymptomatic, malaria syndrome was more common and more severe during seroconversion compared with HIV-negative and HIV-positive intervals. When present, symptoms and physical exam findings were non-specific and associated with higher set point viremia. PMID:22089380
Xu, Hua-Shan; Xu, Zong-Xue; Liu, Pin
2013-03-01
One of the key techniques in establishing and implementing TMDL (total maximum daily load) is to utilize hydrological model to quantify non-point source pollutant loads, establish BMPs scenarios, reduce non-point source pollutant loads. Non-point source pollutant loads under different years (wet, normal and dry year) were estimated by using SWAT model in the Zhangweinan River basin, spatial distribution characteristics of non-point source pollutant loads were analyzed on the basis of the simulation result. During wet years, total nitrogen (TN) and total phosphorus (TP) accounted for 0.07% and 27.24% of the total non-point source pollutant loads, respectively. Spatially, agricultural and residential land with steep slope are the regions that contribute more non-point source pollutant loads in the basin. Compared to non-point source pollutant loads with those during the baseline period, 47 BMPs scenarios were set to simulate the reduction efficiency of different BMPs scenarios for 5 kinds of pollutants (organic nitrogen, organic phosphorus, nitrate nitrogen, dissolved phosphorus and mineral phosphorus) in 8 prior controlled subbasins. Constructing vegetation type ditch was optimized as the best measure to reduce TN and TP by comparing cost-effective relationship among different BMPs scenarios, and the costs of unit pollutant reduction are 16.11-151.28 yuan x kg(-1) for TN, and 100-862.77 yuan x kg(-1) for TP, which is the most cost-effective measure among the 47 BMPs scenarios. The results could provide a scientific basis and technical support for environmental protection and sustainable utilization of water resources in the Zhangweinan River basin.
NASA Astrophysics Data System (ADS)
Guo, W. C.; Yang, J. D.; Chen, J. P.; Peng, Z. Y.; Zhang, Y.; Chen, C. C.
2016-11-01
Load rejection test is one of the essential tests that carried out before the hydroelectric generating set is put into operation formally. The test aims at inspecting the rationality of the design of the water diversion and power generation system of hydropower station, reliability of the equipment of generating set and the dynamic characteristics of hydroturbine governing system. Proceeding from different accident conditions of hydroelectric generating set, this paper presents the transient processes of load rejection corresponding to different accident conditions, and elaborates the characteristics of different types of load rejection. Then the numerical simulation method of different types of load rejection is established. An engineering project is calculated to verify the validity of the method. Finally, based on the numerical simulation results, the relationship among the different types of load rejection and their functions on the design of hydropower station and the operation of load rejection test are pointed out. The results indicate that: The load rejection caused by the accident within the hydroelectric generating set is realized by emergency distributing valve, and it is the basis of the optimization for the closing law of guide vane and the calculation of regulation and guarantee. The load rejection caused by the accident outside the hydroelectric generating set is realized by the governor. It is the most efficient measure to inspect the dynamic characteristics of hydro-turbine governing system, and its closure rate of guide vane set in the governor depends on the optimization result in the former type load rejection.
Hyle, Emily P; Jani, Ilesh V; Rosettie, Katherine L; Wood, Robin; Osher, Benjamin; Resch, Stephen; Pei, Pamela P; Maggiore, Paolo; Freedberg, Kenneth A; Peter, Trevor; Parker, Robert A; Walensky, Rochelle P
2017-09-24
To examine the clinical and economic value of point-of-care CD4 (POC-CD4) or viral load monitoring compared with current practices in Mozambique, a country representative of the diverse resource limitations encountered by HIV treatment programs in sub-Saharan Africa. We use the Cost-Effectiveness of Preventing AIDS Complications-International model to examine the clinical impact, cost (2014 US$), and incremental cost-effectiveness ratio [$/year of life saved (YLS)] of ART monitoring strategies in Mozambique. We compare: monitoring for clinical disease progression [clinical ART monitoring strategy (CLIN)] vs. annual POC-CD4 in rural settings without laboratory services and biannual laboratory CD4 (LAB-CD4), biannual POC-CD4, and annual viral load in urban settings with laboratory services. We examine the impact of a range of values in sensitivity analyses, using Mozambique's 2014 per capita gross domestic product ($620) as a benchmark cost-effectiveness threshold. In rural settings, annual POC-CD4 compared to CLIN improves life expectancy by 2.8 years, reduces time on failed ART by 0.6 years, and yields an incremental cost-effectiveness ratio of $480/YLS. In urban settings, biannual POC-CD4 is more expensive and less effective than viral load. Compared to biannual LAB-CD4, viral load improves life expectancy by 0.6 years, reduces time on failed ART by 1.0 year, and is cost-effective ($440/YLS). In rural settings, annual POC-CD4 improves clinical outcomes and is cost-effective compared to CLIN. In urban settings, viral load has the greatest clinical benefit and is cost-effective compared to biannual POC-CD4 or LAB-CD4. Tailoring ART monitoring strategies to specific settings with different available resources can improve clinical outcomes while remaining economically efficient.
Fluid/electrolyte and endocrine changes in space flight
NASA Technical Reports Server (NTRS)
Huntoon, Carolyn Leach
1989-01-01
The primary effects of space flight that influence the endocrine system and fluid and electrolyte regulation are the reduction of hydrostatic gradients, reduction in use and gravitational loading of bone and muscle, and stress. Each of these sets into motion a series of responses that culminates in alteration of some homeostatic set points for the environment of space. Set point alterations are believed to include decreases in venous pressure; red blood cell mass; total body water; plasma volume; and serum sodium, chloride, potassium, and osmolality. Serum calcium and phosphate increase. Hormones such as erythropoietin, atrial natriuretic peptide, aldosterone, cortisol, antidiuretic hormone, and growth hormone are involved in the dynamic processes that bring about the new set points. The inappropriateness of microgravity set points for 1-G conditions contributes to astronaut postflight responses.
Point of Care Technologies for HIV
Hewlett, Indira K.
2014-01-01
Effective prevention of HIV/AIDS requires early diagnosis, initiation of therapy, and regular plasma viral load monitoring of the infected individual. In addition, incidence estimation using accurate and sensitive assays is needed to facilitate HIV prevention efforts in the public health setting. Therefore, more affordable and accessible point-of-care (POC) technologies capable of providing early diagnosis, HIV viral load measurements, and CD4 counts in settings where HIV is most prevalent are needed to enable appropriate intervention strategies and ultimately stop transmission of the virus within these populations to achieve the future goal of an AIDS-free generation. This review discusses the available and emerging POC technologies for future application to these unmet public health needs. PMID:24579041
Research on stratified evolution of composite materials under four-point bending loading
NASA Astrophysics Data System (ADS)
Hao, M. J.; You, Q. J.; Zheng, J. C.; Yue, Z.; Xie, Z. P.
2017-12-01
In order to explore the effect of stratified evolution and delamination on the load capacity and service life of the composite materials under the four-point bending loading, the artificial tectonic defects of the different positions were set up. The four-point bending test was carried out, and the whole process was recorded by acoustic emission, and the damage degree of the composite layer was judged by the impact accumulation of the specimen - time-amplitude history chart, load-time-relative energy history chart, acoustic emission impact signal positioning map. The results show that the stratified defects near the surface of the specimen accelerate the process of material failure and expansion. The location of the delamination defects changes the bending performance of the composites to a great extent. The closer the stratification defects are to the surface of the specimen, the greater the damage, the worse the service capacity of the specimen.
Papasavvas, Emmanouil; Foulkes, Andrea; Yin, Xiangfan; Joseph, Jocelin; Ross, Brian; Azzoni, Livio; Kostman, Jay R; Mounzer, Karam; Shull, Jane; Montaner, Luis J
2015-07-01
The identification of immune correlates of HIV control is important for the design of immunotherapies that could support cure or antiretroviral therapy (ART) intensification-related strategies. ART interruptions may facilitate this task through exposure of an ART partially reconstituted immune system to endogenous virus. We investigated the relationship between set-point plasma HIV viral load (VL) during an ART interruption and innate/adaptive parameters before or after interruption. Dendritic cell (DC), natural killer (NK) cell and HIV Gag p55-specific T-cell functional responses were measured in paired cryopreserved peripheral blood mononuclear cells obtained at the beginning (on ART) and at set-point of an open-ended interruption from 31 ART-suppressed chronically HIV-1(+) patients. Spearman correlation and linear regression modeling were used. Frequencies of plasmacytoid DC (pDC), and HIV Gag p55-specific CD3(+) CD4(-) perforin(+) IFN-γ(+) cells at the beginning of interruption associated negatively with set-point plasma VL. Inclusion of both variables with interaction into a model resulted in the best fit (adjusted R(2) = 0·6874). Frequencies of pDC or HIV Gag p55-specific CD3(+) CD4(-) CSFE(lo) CD107a(+) cells at set-point associated negatively with set-point plasma VL. The dual contribution of pDC and anti-HIV T-cell responses to viral control, supported by our models, suggests that these variables may serve as immune correlates of viral control and could be integrated in cure or ART-intensification strategies. © 2015 John Wiley & Sons Ltd.
Advances in Developing HIV-1 Viral Load Assays for Resource-Limited Settings
Wang, ShuQi; Xu, Feng; Demirci, Utkan
2010-01-01
Commercial HIV-1 RNA viral load assays have been routinely used in developed countries to monitor antiretroviral treatment (ART). However, these assays require expensive equipment and reagents, well-trained operators, and established laboratory infrastructure. These requirements restrict their use in resource-limited settings where people are most afflicted with the HIV-1 epidemic. Inexpensive alternatives such as the Ultrasensitive p24 assay, the Reverse Transcriptase (RT) assay and in-house reverse transcription quantitative polymerase chain reaction (RT-qPCR) have been developed. However, they are still time-consuming, technologically complex and inappropriate for decentralized laboratories as point-of-care (POC) tests. Recent advances in microfluidics and nanotechnology offer new strategies to develop low-cost, rapid, robust and simple HIV-1 viral load monitoring systems. We review state-of-the-art technologies used for HIV-1 viral load monitoring in both developed and developing settings. Emerging approaches based on microfluidics and nanotechnology, which have potential to be integrated into POC HIV-1 viral load assays, are also discussed. PMID:20600784
Combined Space and Water Heating: Next Steps to Improved Performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. Schoenbauer; Bohac, D.; Huelman, P.
2016-07-13
A combined space- and water-heating (combi) system uses a high-efficiency direct-vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that using condensing water heaters or boilers with hydronic air handling units can provide both space and water heating with efficiencies of 90% or higher. Improved controls have the potential to reduce complexity and improve upon the measured performance. This project demonstrates that controls can significantly benefit these first-generation systems. Laboratory tests and daily load/performance models showed that the set point temperature reset control produced a 2.1%–4.3% (20–40 therms/year) savings for storage andmore » hybrid water heater combi systems operated in moderate-load homes. The full modulation control showed additional savings over set point control (in high-load homes almost doubling the savings: 4%–5% over the no-control case). At the time of installation the reset control can be implemented for $200–$400, which would provide paybacks of 6–25 years for low-load houses and 3–15 years for high-load houses. Full modulation implementation costs would be similar to the outdoor reset and would provide paybacks of 5-½–20 years for low-load houses and 2-½–10 years for high-load houses.« less
On load paths and load bearing topology from finite element analysis
NASA Astrophysics Data System (ADS)
Kelly, D.; Reidsema, C.; Lee, M.
2010-06-01
Load paths can be mapped from vector plots of 'pointing stress vectors'. They define a path along which a component of load remains constant as it traverses the solution domain. In this paper the theory for the paths is first defined. Properties of the plots that enable a designer to interpret the structural behavior from the contours are then identified. Because stress is a second order tensor defined on an orthogonal set of axes, the vector plots define separate paths for load transfer in each direction of the set of axes. An algorithm is therefore presented that combines the vectors to define a topology to carry the loads. The algorithm is shown to straighten the paths reducing bending moments and removing stress concentration. Application to a bolted joint, a racing car body and a yacht hull demonstrate the usefulness of the plots.
Strain gage selection in loads equations using a genetic algorithm
NASA Technical Reports Server (NTRS)
1994-01-01
Traditionally, structural loads are measured using strain gages. A loads calibration test must be done before loads can be accurately measured. In one measurement method, a series of point loads is applied to the structure, and loads equations are derived via the least squares curve fitting algorithm using the strain gage responses to the applied point loads. However, many research structures are highly instrumented with strain gages, and the number and selection of gages used in a loads equation can be problematic. This paper presents an improved technique using a genetic algorithm to choose the strain gages used in the loads equations. Also presented are a comparison of the genetic algorithm performance with the current T-value technique and a variant known as the Best Step-down technique. Examples are shown using aerospace vehicle wings of high and low aspect ratio. In addition, a significant limitation in the current methods is revealed. The genetic algorithm arrived at a comparable or superior set of gages with significantly less human effort, and could be applied in instances when the current methods could not.
Jacobson, Jeffrey M; Pat Bucy, R; Spritzler, John; Saag, Michael S; Eron, Joseph J; Coombs, Robert W; Wang, Rui; Fox, Lawrence; Johnson, Victoria A; Cu-Uvin, Susan; Cohn, Susan E; Mildvan, Donna; O'Neill, Dorothy; Janik, Jennifer; Purdue, Lynette; O'Connor, Deborah K; Vita, Christine Di; Frank, Ian
2006-09-01
The ability to control human immunodeficiency virus (HIV) replication in vivo in the absence of antiretroviral therapy (ART) is a measure of the efficiency of antiviral immunity. In a study of patients with chronic, ART-suppressed HIV infection, AIDS Clinical Trials Group 5068 investigated the effects of immunization with an exogenous HIV vaccine and pulse exposure to the subject's unique viral epitopes, by means of structured treatment interruptions (STIs), on the dynamics of viral rebound during a subsequent analytical treatment interruption (ATI). Ninety-seven subjects receiving stable ART with an HIV-1 RNA load <50 copies/mL and CD4(+) T lymphocyte count >400 cells/mm(3) were randomized to undergo continued ART, STIs, ALVAC-HIV vCP1452 immunization, or STIs and ALVAC-HIV vCP1452 immunization. Subjects in the 2 STI arms had a significantly longer median doubling time in the period of the initial rise of viral load, a significantly lower median peak viral load, a significantly lower median end-of-ATI viral load set point, and a greater proportion of subjects with an end-of-ATI viral load set point <1,000 copies/mL, compared with the subjects in the 2 arms without STIs. With an immunization schedule of 3 sets of 3 weekly injections, ALVAC-HIV vCP1452 did not affect viral load measures. In this randomized, controlled study of intermittent STI as a therapeutic autoimmunization strategy, evidence of enhanced immunologic control of HIV replication was demonstrated.
Assessment of New Load Schedules for the Machine Calibration of a Force Balance
NASA Technical Reports Server (NTRS)
Ulbrich, N.; Gisler, R.; Kew, R.
2015-01-01
New load schedules for the machine calibration of a six-component force balance are currently being developed and evaluated at the NASA Ames Balance Calibration Laboratory. One of the proposed load schedules is discussed in the paper. It has a total of 2082 points that are distributed across 16 load series. Several criteria were applied to define the load schedule. It was decided, for example, to specify the calibration load set in force balance format as this approach greatly simplifies the definition of the lower and upper bounds of the load schedule. In addition, all loads are assumed to be applied in a calibration machine by using the one-factor-at-a-time approach. At first, all single-component loads are applied in six load series. Then, three two-component load series are applied. They consist of the load pairs (N1, N2), (S1, S2), and (RM, AF). Afterwards, four three-component load series are applied. They consist of the combinations (N1, N2, AF), (S1, S2, AF), (N1, N2, RM), and (S1, S2, RM). In the next step, one four-component load series is applied. It is the load combination (N1, N2, S1, S2). Finally, two five-component load series are applied. They are the load combination (N1, N2, S1, S2, AF) and (N1, N2, S1, S2, RM). The maximum difference between loads of two subsequent data points of the load schedule is limited to 33 % of capacity. This constraint helps avoid unwanted load "jumps" in the load schedule that can have a negative impact on the performance of a calibration machine. Only loadings of the single- and two-component load series are loaded to 100 % of capacity. This approach was selected because it keeps the total number of calibration points to a reasonable limit while still allowing for the application of some of the more complex load combinations. Data from two of NASA's force balances is used to illustrate important characteristics of the proposed 2082-point calibration load schedule.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2017-11-06
ImagingSIMS is an open source application for loading, processing, manipulating and visualizing secondary ion mass spectrometry (SIMS) data. At PNNL, a separate branch has been further developed to incorporate application specific features for dynamic SIMS data sets. These include loading CAMECA IMS-1280, NanoSIMS and modified IMS-4f raw data, creating isotopic ratio images and stitching together images from adjacent interrogation regions. In addition to other modifications of the parent open source version, this version is equipped with a point-by-point image registration tool to assist with streamlining the image fusion process.
NASA Technical Reports Server (NTRS)
Chan, William Machado; Pandya, Shishir Ashok; Rogers, Stuart E.
2013-01-01
Recent developments on the automation of the X-rays approach to hole-cutting in over- set grids is further improved. A fast method to compute an auxiliary wall-distance function used in providing a rst estimate of the hole boundary location is introduced. Subsequent iterations lead to automatically-created hole boundaries with a spatially-variable o set from the minimum hole. For each hole boundary location, an averaged cell attribute measure over all fringe points is used to quantify the compatibility between the fringe points and their respective donor cells. The sensitivity of aerodynamic loads to di erent hole boundary locations and cell attribute compatibilities is investigated using four test cases: an isolated re-entry capsule, a two-rocket con guration, the AIAA 4th Drag Prediction Workshop Common Research Model (CRM), and the D8 \\Double Bubble" subsonic aircraft. When best practices in hole boundary treatment are followed, only small variations in integrated loads and convergence rates are observed for different hole boundary locations.
Manning, William A; Ghosh, Kanishka M; Blain, Alasdair P; Longstaff, Lee M; Rushton, Steven P; Deehan, David J
2017-06-01
Tibial component rotation at time of knee arthroplasty can influence conformity, load transmission across the polyethylene surface, and perhaps ultimately determined survivorship. Optimal tibial component rotation on the cut surface is reliant on standard per operative manual stressing. This subjective assessment aims to balance constraint and stability of the articulation through a full arc of movement. Using a cadaveric model, computer navigation and under defined, previously validated loaded conditions mimicking the in vivo setting, the influence of maximal tibial component external rotation compared with the neutral state was examined for changes in laxity and tibiofemoral continuous load using 3D displacement measurement and an orthosensor continuous load sensor implanted within the polyethylene spacer in a simulated single radius total knee arthroplasty. No significant difference was found throughout arc of motion (0-115 degrees of flexion) for maximal varus and/or valgus or rotatory laxity between the 2 states. The neutral state achieved equivalence for mediolateral load distribution at each point of flexion. We have found that external rotation of the tibial component increased medial compartment load in comparison with the neutral position. Compared with the neutral state, external rotation consistently effected a marginal, but not significant reduction in lateral load under similar loading conditions. The effects were most pronounced in midflexion. On the basis of these findings, we would advocate for the midtibial tubercle point to determine tibial component rotation and caution against component external rotation. Copyright © 2017 Elsevier Inc. All rights reserved.
Vegetation community change points suggest that critical loads of nutrient nitrogen may be too high
NASA Astrophysics Data System (ADS)
Wilkins, Kayla; Aherne, Julian; Bleasdale, Andy
2016-12-01
It is widely accepted that elevated nitrogen deposition can have detrimental effects on semi-natural ecosystems, including changes to plant diversity. Empirical critical loads of nutrient nitrogen have been recommended to protect many sensitive European habitats from significant harmful effects. In this study, we used Threshold Indicator Taxa Analysis (TITAN) to investigate shifts in vegetation communities along an atmospheric nitrogen deposition gradient for twenty-two semi-natural habitat types (as described under Annex I of the European Union Habitats Directive) in Ireland. Significant changes in vegetation community, i.e., change points, were determined for twelve habitats, with seven habitats showing a decrease in the number of positive indicator species. Community-level change points indicated a decrease in species abundance along a nitrogen deposition gradient ranging from 3.9 to 15.3 kg N ha-1 yr-1, which were significantly lower than recommended critical loads (Wilcoxon signed-rank test; V = 6, p < 0.05). These results suggest that lower critical loads of empirical nutrient nitrogen deposition may be required to protect many European habitats. Changes to vegetation communities may mean a loss of sensitive indicator species and potentially rare species in these habitats, highlighting how emission reductions policies set under the National Emissions Ceilings Directive may be directly linked to meeting the goal set out under the European Union's Biodiversity Strategy of "halting the loss of biodiversity" across Europe by 2020.
Winkler, Jon; Munk, Jeffrey; Woods, Jason
2018-04-01
Increasing insulation levels and improved windows are reducing sensible cooling loads in high-efficiency homes. This trend raises concerns that the resulting shift in the balance of sensible and latent cooling loads may result in higher indoor humidity, occupant discomfort, and stunted adoption of high-efficiency homes. This study utilizes established moisture-buffering and air-conditioner latent degradation models in conjunction with an approach to stochastically model internal gains. Building loads and indoor humidity levels are compared for simulations of typical new construction homes and high-efficiency homes in 10 US cities. The sensitivity of indoor humidity to changes in cooling set point, air-conditioner capacity,more » and blower control parameters are evaluated. The results show that high-efficiency homes in humid climates have cooling loads with a higher fraction of latent loads than the typical new construction home, resulting in higher indoor humidity. Reducing the cooling set point is the easiest method to reduce indoor humidity, but it is not energy efficient, and overcooling may lead to occupant discomfort. Eliminating the blower operation at the end of cooling cycles and reducing the cooling airflow rate also reduce indoor humidity and with a smaller impact on energy use and comfort.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winkler, Jon; Munk, Jeffrey; Woods, Jason
Increasing insulation levels and improved windows are reducing sensible cooling loads in high-efficiency homes. This trend raises concerns that the resulting shift in the balance of sensible and latent cooling loads may result in higher indoor humidity, occupant discomfort, and stunted adoption of high-efficiency homes. This study utilizes established moisture-buffering and air-conditioner latent degradation models in conjunction with an approach to stochastically model internal gains. Building loads and indoor humidity levels are compared for simulations of typical new construction homes and high-efficiency homes in 10 US cities. The sensitivity of indoor humidity to changes in cooling set point, air-conditioner capacity,more » and blower control parameters are evaluated. The results show that high-efficiency homes in humid climates have cooling loads with a higher fraction of latent loads than the typical new construction home, resulting in higher indoor humidity. Reducing the cooling set point is the easiest method to reduce indoor humidity, but it is not energy efficient, and overcooling may lead to occupant discomfort. Eliminating the blower operation at the end of cooling cycles and reducing the cooling airflow rate also reduce indoor humidity and with a smaller impact on energy use and comfort.« less
Dynamic strain distribution of FRP plate under blast loading
NASA Astrophysics Data System (ADS)
Saburi, T.; Yoshida, M.; Kubota, S.
2017-02-01
The dynamic strain distribution of a fiber re-enforced plastic (FRP) plate under blast loading was investigated using a Digital Image Correlation (DIC) image analysis method. The testing FRP plates were mounted in parallel to each other on a steel frame. 50 g of composition C4 explosive was used as a blast loading source and set in the center of the FRP plates. The dynamic behavior of the FRP plate under blast loading were observed by two high-speed video cameras. The set of two high-speed video image sequences were used to analyze the FRP three-dimensional strain distribution by means of DIC method. A point strain profile extracted from the analyzed strain distribution data was compared with a directly observed strain profile using a strain gauge and it was shown that the strain profile under the blast loading by DIC method is quantitatively accurate.
Herbeck, Joshua T.; Müller, Viktor; Maust, Brandon S.; Ledergerber, Bruno; Torti, Carlo; Di Giambenedetto, Simona; Gras, Luuk; Günthard, Huldrych F.; Jacobson, Lisa P.; Mullins, James I.; Gottlieb, Geoffrey S.
2013-01-01
Objective The potential for changing HIV-1 virulence has significant implications for the AIDS epidemic, including changing HIV transmission rates, rapidity of disease progression, and timing of ART. Published data to date have provided conflicting results. Design We conducted a meta-analysis of changes in baseline CD4+ T-cell counts and set point plasma viral RNA load over time in order to establish whether summary trends are consistent with changing HIV-1 virulence. Methods We searched PubMed for studies of trends in HIV-1 prognostic markers of disease progression and supplemented findings with publications referenced in epidemiological or virulence studies. We identified 12 studies of trends in baseline CD4+ T-cell counts (21 052 total individuals), and eight studies of trends in set point viral loads (10 785 total individuals), spanning the years 1984–2010. Using random-effects meta-analysis, we estimated summary effect sizes for trends in HIV-1 plasma viral loads and CD4+ T-cell counts. Results Baseline CD4+ T-cell counts showed a summary trend of decreasing cell counts [effect=−4.93 cells/µl per year, 95% confidence interval (CI) −6.53 to −3.3]. Set point viral loads showed a summary trend of increasing plasma viral RNA loads (effect=0.013 log10 copies/ml per year, 95% CI −0.001 to 0.03). The trend rates decelerated in recent years for both prognostic markers. Conclusion Our results are consistent with increased virulence of HIV-1 over the course of the epidemic. Extrapolating over the 30 years since the first description of AIDS, this represents a CD4+ T cells loss of approximately 148 cells/µl and a gain of 0.39 log10 copies/ml of viral RNA measured during early infection. These effect sizes would predict increasing rates of disease progression, and need for ART as well as increasing transmission risk. PMID:22089381
LabVIEW Serial Driver Software for an Electronic Load
NASA Technical Reports Server (NTRS)
Scullin, Vincent; Garcia, Christopher
2003-01-01
A LabVIEW-language computer program enables monitoring and control of a Transistor Devices, Inc., Dynaload WCL232 (or equivalent) electronic load via an RS-232 serial communication link between the electronic load and a remote personal computer. (The electronic load can operate at constant voltage, current, power consumption, or resistance.) The program generates a graphical user interface (GUI) at the computer that looks and acts like the front panel of the electronic load. Once the electronic load has been placed in remote-control mode, this program first queries the electronic load for the present values of all its operational and limit settings, and then drops into a cycle in which it reports the instantaneous voltage, current, and power values in displays that resemble those on the electronic load while monitoring the GUI images of pushbuttons for control actions by the user. By means of the pushbutton images and associated prompts, the user can perform such operations as changing limit values, the operating mode, or the set point. The benefit of this software is that it relieves the user of the need to learn one method for operating the electronic load locally and another method for operating it remotely via a personal computer.
NASA Technical Reports Server (NTRS)
Morris, C. E. K., Jr.; Tomaine, R. L.; Stevens, D. D.
1979-01-01
Data on performance and rotor loads for a teetering-rotor, AH-1G helicopter flown with a main rotor that had the NLR-1T airfoil as the blade-section contour are presented. The test envelope included hover, forward-flight speed sweeps from 35 to 85 m/sec, and collective-fixed maneuvers at about 0.25 tip-speed ratio. The data set for each test point described vehicle flight state, control positions, rotor loads, power requirements, and blade motions. Rotor loads are reviewed primarily in terms of peak-to-peak and harmonic content. Lower frequency components predominated for most loads and generally increased with increased airspeed, but not necessarily with increased maneuver load factor.
Manned maneuvering unit latching mechanism
NASA Technical Reports Server (NTRS)
Allton, C. S.
1980-01-01
The astronaut/Manned Maneuvering Unit interface, which presented a challenging set of requirements for a latching mechanism, is described. A spring loaded cam segment with variable ratio pulley release actuator was developed to meet the requirements. To preclude jamming of the mechanism, special precautions were taken such as spring loaded bearing points and careful selection of materials to resist cold welding. The mechanism successfully passed a number of tests which partially simulated orbital conditions.
NASA Astrophysics Data System (ADS)
Doležel, Jiří; Novák, Drahomír; Petrů, Jan
2017-09-01
Transportation routes of oversize and excessive loads are currently planned in relation to ensure the transit of a vehicle through critical points on the road. Critical points are level-intersection of roads, bridges etc. This article presents a comprehensive procedure to determine a reliability and a load-bearing capacity level of the existing bridges on highways and roads using the advanced methods of reliability analysis based on simulation techniques of Monte Carlo type in combination with nonlinear finite element method analysis. The safety index is considered as a main criterion of the reliability level of the existing construction structures and the index is described in current structural design standards, e.g. ISO and Eurocode. An example of a single-span slab bridge made of precast prestressed concrete girders of the 60 year current time and its load bearing capacity is set for the ultimate limit state and serviceability limit state. The structure’s design load capacity was estimated by the full probability nonlinear MKP analysis using a simulation technique Latin Hypercube Sampling (LHS). Load-bearing capacity values based on a fully probabilistic analysis are compared with the load-bearing capacity levels which were estimated by deterministic methods of a critical section of the most loaded girders.
Li, Kai; Zeng, Fan-Tang; Fang, Huai-Yang; Lin, Shu
2013-11-01
Based on the Long-term Hydrological Impact Assessment (L-THIA) model, the effect of land use and rainfall change on nitrogen and phosphorus loading of non-point sources in Shiqiao river watershed was analyzed. The parameters in L-THIA model were revised according to the data recorded in the scene of runoff plots, which were set up in the watershed. The results showed that the distribution of areas with high pollution load was mainly concentrated in agricultural land and urban land. Agricultural land was the biggest contributor to nitrogen and phosphorus load. From 1995 to 2010, the load of major pollutants, namely TN and TP, showed an obviously increasing trend with increase rates of 17.91% and 25.30%, respectively. With the urbanization in the watershed, urban land increased rapidly and its area proportion reached 43.94%. The contribution of urban land to nitrogen and phosphorus load was over 40% in 2010. This was the main reason why pollution load still increased obviously while the agricultural land decreased greatly in the past 15 years. The rainfall occurred in the watershed was mainly concentrated in the flood season, so the nitrogen and phosphorus load of the flood season was far higher than that of the non-flood season and the proportion accounting for the whole year was over 85%. Pearson regression analysis between pollution load and the frequency of different patterns of rainfall demonstrated that rainfall exceeding 20 mm in a day was the main rainfall type causing non-point source pollution.
Planetary Load Sharing in Three-Point Mounted Wind Turbine Gearboxes: A Design and Test Comparison
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keller, Jonathan; Guo, Yi; Zhang, Zhiwei
This work compares the planetary load-sharing characteristics of wind turbine gearboxes supported by cylindrical roller bearings (CRBs) and preloaded tapered roller bearings (TRBs) when subjected to rotor moments. Planetary bearing loads were measured in field-representative dynamometer tests and compared to loads predicted by finite-element models. Preloaded TRBs significantly improved load sharing. In pure torque conditions, the upwind planet bearing load in the gearbox with preloaded TRBs was only 14% more than the assumed load compared to 47% more for the gearbox with CRBs. Consequently, the predicted fatigue life of the complete set of planetary bearings for the gearbox with preloadedmore » TRBs is 3.5 times greater than that of the gearbox with CRBs.« less
Kulkarni, Smita; Jadhav, Sushama; Khopkar, Priyanka; Sane, Suvarna; Londhe, Rajkumar; Chimanpure, Vaishali; Dhilpe, Veronica; Ghate, Manisha; Yelagate, Rajendra; Panchal, Narayan; Rahane, Girish; Kadam, Dilip; Gaikwad, Nitin; Rewari, Bharat; Gangakhedkar, Raman
2017-07-21
Recent WHO guidelines identify virologic monitoring for diagnosing and confirming ART failure. In view of this, validation and scale up of point of care viral load technologies is essential in resource limited settings. A systematic validation of the GeneXpert® HIV-1 Quant assay (a point-of-care technology) in view of scaling up HIV-1 viral load in India to monitor the success of national ART programme was carried out. Two hundred nineteen plasma specimens falling in nine viral load ranges (<40 to >5 L copies/ml) were tested by the Abbott m2000rt Real Time and GeneXpert HIV-1 Quant assays. Additionally, 20 seronegative; 16 stored specimens and 10 spiked controls were also tested. Statistical analysis was done using Stata/IC and sensitivity, specificity, PPV, NPV and %misclassification rates were calculated as per DHSs/AISs, WHO, NACO cut-offs for virological failure. The GeneXpert assay compared well with the Abbott assay with a higher sensitivity (97%), specificity (97-100%) and concordance (91.32%). The correlation between two assays (r = 0.886) was statistically significant (p < 0.01), the linear regression showed a moderate fit (R 2 = 0.784) and differences were within limits of agreement. Reproducibility showed an average variation of 4.15 and 3.52% while Lower limit of detection (LLD) and Upper limit of detection (ULD) were 42 and 1,740,000 copies/ml respectively. The misclassification rates for three viral load cut offs were not statistically different (p = 0.736). All seronegative samples were negative and viral loads of the stored samples showed a good fit (R 2 = 0.896 to 0.982). The viral load results of GeneXpert HIV-1 Quant assay compared well with Abbott HIV-1 m2000 Real Time PCR; suggesting its use as a Point of care assay for viral load estimation in resource limited settings. Its ease of performance and rapidity will aid in timely diagnosis of ART failures, integrated HIV-TB management and will facilitate the UNAIDS 90-90-90 target.
NASA Astrophysics Data System (ADS)
McClurg, Jack Albert
The objective set forth in this study was to thoroughly document the effects of heat, moisture, and loading conditions on a variety of pultruded unidirectional fiberglass reinforced composite materials. This study incorporated the use of two environmental control chambers and two water immersion tanks in order to provide the necessary range of environmental exposure conditions. A set of specially designed stainless steel loading fixtures was produced in order to introduce the factor of external loading of the specimens while exposed to the predetermined environmental condition and how that would affect the mechanical and physical properties in question. The properties of interest were the flexural strength (determined using the three-point flexural bending method), flexural modulus (determined using the three-point flexural bending method), and glass transition temperature of the material (determined using differential scanning calorimetry). Other data that was noted during the conditioning and testing of the specimens was the break type (flexural tension, compression, shear, etc...), the change in dimensions (prior to exposure vs. after exposure), and the change in weight (prior to exposure vs. after exposure). Using all of the information that was obtained from this study, a more detailed understanding of how and why fiberglass reinforced materials react the way they do when exposed to moisture and elevated temperature was drawn. This study is different from most others in that it explores the interactions of three independent variables (heat, moisture, and loading condition) on three different fiberglass reinforced composite systems (epoxy, vinylester, and polyester resin).
Development of a Numerical Model for High-Temperature Shape Memory Alloys
NASA Technical Reports Server (NTRS)
DeCastro, Jonathan A.; Melcher, Kevin J.; Noebe, Ronald D.; Gaydosh, Darrell J.
2006-01-01
A thermomechanical hysteresis model for a high-temperature shape memory alloy (HTSMA) actuator material is presented. The model is capable of predicting strain output of a tensile-loaded HTSMA when excited by arbitrary temperature-stress inputs for the purpose of actuator and controls design. Common quasi-static generalized Preisach hysteresis models available in the literature require large sets of experimental data for model identification at a particular operating point, and substantially more data for multiple operating points. The novel algorithm introduced here proposes an alternate approach to Preisach methods that is better suited for research-stage alloys, such as recently-developed HTSMAs, for which a complete database is not yet available. A detailed description of the minor loop hysteresis model is presented in this paper, as well as a methodology for determination of model parameters. The model is then qualitatively evaluated with respect to well-established Preisach properties and against a set of low-temperature cycled loading data using a modified form of the one-dimensional Brinson constitutive equation. The computationally efficient algorithm demonstrates adherence to Preisach properties and excellent agreement to the validation data set.
Reeves, Daniel B; Peterson, Christopher W; Kiem, Hans-Peter; Schiffer, Joshua T
2017-07-01
Primary HIV-1 infection induces a virus-specific adaptive/cytolytic immune response that impacts the plasma viral load set point and the rate of progression to AIDS. Combination antiretroviral therapy (cART) suppresses plasma viremia to undetectable levels that rebound upon cART treatment interruption. Following cART withdrawal, the memory component of the virus-specific adaptive immune response may improve viral control compared to primary infection. Here, using primary infection and treatment interruption data from macaques infected with simian/human immunodeficiency virus (SHIV), we observe a lower peak viral load but an unchanged viral set point during viral rebound. The addition of an autologous stem cell transplant before cART withdrawal alters viral dynamics: we found a higher rebound set point but similar peak viral loads compared to the primary infection. Mathematical modeling of the data that accounts for fundamental immune parameters achieves excellent fit to heterogeneous viral loads. Analysis of model output suggests that the rapid memory immune response following treatment interruption does not ultimately lead to better viral containment. Transplantation decreases the durability of the adaptive immune response following cART withdrawal and viral rebound. Our model's results highlight the impact of the endogenous adaptive immune response during primary SHIV infection. Moreover, because we capture adaptive immune memory and the impact of transplantation, this model will provide insight into further studies of cure strategies inspired by the Berlin patient. IMPORTANCE HIV patients who interrupt combination antiretroviral therapy (cART) eventually experience viral rebound, the return of viral loads to pretreatment levels. However, the "Berlin patient" remained free of HIV rebound over a decade after stopping cART. His cure is attributed to leukemia treatment that included an HIV-resistant stem cell transplant. Inspired by this case, we studied the impact of stem cell transplantation in a macaque simian/HIV (SHIV) system. Using a mechanistic mathematical model, we found that while primary infection generates an adaptive immune memory response, stem cell transplantation disrupts this learned immunity. The results have implications for HIV cure regimens based on stem cell transplantation. Copyright © 2017 American Society for Microbiology.
Peterson, Christopher W.; Kiem, Hans-Peter
2017-01-01
ABSTRACT Primary HIV-1 infection induces a virus-specific adaptive/cytolytic immune response that impacts the plasma viral load set point and the rate of progression to AIDS. Combination antiretroviral therapy (cART) suppresses plasma viremia to undetectable levels that rebound upon cART treatment interruption. Following cART withdrawal, the memory component of the virus-specific adaptive immune response may improve viral control compared to primary infection. Here, using primary infection and treatment interruption data from macaques infected with simian/human immunodeficiency virus (SHIV), we observe a lower peak viral load but an unchanged viral set point during viral rebound. The addition of an autologous stem cell transplant before cART withdrawal alters viral dynamics: we found a higher rebound set point but similar peak viral loads compared to the primary infection. Mathematical modeling of the data that accounts for fundamental immune parameters achieves excellent fit to heterogeneous viral loads. Analysis of model output suggests that the rapid memory immune response following treatment interruption does not ultimately lead to better viral containment. Transplantation decreases the durability of the adaptive immune response following cART withdrawal and viral rebound. Our model's results highlight the impact of the endogenous adaptive immune response during primary SHIV infection. Moreover, because we capture adaptive immune memory and the impact of transplantation, this model will provide insight into further studies of cure strategies inspired by the Berlin patient. IMPORTANCE HIV patients who interrupt combination antiretroviral therapy (cART) eventually experience viral rebound, the return of viral loads to pretreatment levels. However, the “Berlin patient” remained free of HIV rebound over a decade after stopping cART. His cure is attributed to leukemia treatment that included an HIV-resistant stem cell transplant. Inspired by this case, we studied the impact of stem cell transplantation in a macaque simian/HIV (SHIV) system. Using a mechanistic mathematical model, we found that while primary infection generates an adaptive immune memory response, stem cell transplantation disrupts this learned immunity. The results have implications for HIV cure regimens based on stem cell transplantation. PMID:28404854
NASA Astrophysics Data System (ADS)
Legeay, Pierre-Louis; Moatar, Florentina; Gascuel-Odoux, Chantal; Gruau, Gérard
2015-04-01
In intensive agricultural regions with important livestock farming, long-term land application of Phosphorus (P) both as chemical fertilizer and animal wastes, have resulted in elevated P contents in soils. Since we know that high P concentrations in rivers is of major concern, few studies have been done at to assess the spatiotemporal variability of P loads in rivers and apportionment of point and nonpoint source in total loads. Here we focus on Brittany (Western France) where even though P is a great issue in terms of human and drinking water safety (cyano-toxins), environmental protection and economic costs for Brittany with regards to the periodic proliferations of cyanobacteria that occur every year in this region, no regional-scale systematic study has been carried out so far. We selected a set of small rivers (stream order 3-5) with homogeneous agriculture and granitic catchment. By gathering data from three water quality monitoring networks, covering more than 100 measurements stations, we provide a regional-scale quantification of the spatiotemporal variability of dissolved P (DP) and total P (TP) interannual loads from 1992 to 2012. Build on mean P load in low flows and statistical significance tests, we developed a new indicator, called 'low flow P load' (LFP-load), which allows us to determine the importance of domestic and industrial P sources in total P load and to assess their spatiotemporal variability compared to agricultural sources. The calculation and the map representation of DP and TP interannual load variations allow identification of the greatest and lowest P contributory catchments over the study period and the way P loads of Brittany rivers have evolved through time. Both mean DP and TP loads have been divided by more than two over the last 20 years. Mean LFDP-load decreased by more than 60% and mean LFTP-load by more than 45% on average over the same period showing that this marked temporal decrease in total load is largely due to the decrease of domestic and industrial P effluents. A global shift in P inputs apportionment to freshwaters thus occurred in Brittany since 20 years as agricultural nonpoint sources now contribute a greater portion of inputs showing the efficiency of the recent control of point sources by enhancement of water treatment plant and removal of phosphates in detergents. The spatialized P loads provided by this study could give a basis for a better understanding of the factors that drives the P transfers in Brittany soils and hotspots of P emissions while the LFP-load indicator can be a tool to assess effects of point-source P mitigation plans.
Zhang, H X
2008-01-01
An innovative approach for total maximum daily load (TMDL) allocation and implementation is the watershed-based pollutant trading. Given the inherent scientific uncertainty for the tradeoffs between point and nonpoint sources, setting of trading ratios can be a contentious issue and was already listed as an obstacle by several pollutant trading programs. One of the fundamental reasons that a trading ratio is often set higher (e.g. greater than 2) is to allow for uncertainty in the level of control needed to attain water quality standards, and to provide a buffer in case traded reductions are less effective than expected. However, most of the available studies did not provide an approach to explicitly address the determination of trading ratio. Uncertainty analysis has rarely been linked to determination of trading ratio.This paper presents a practical methodology in estimating "equivalent trading ratio (ETR)" and links uncertainty analysis with trading ratio determination from TMDL allocation process. Determination of ETR can provide a preliminary evaluation of "tradeoffs" between various combination of point and nonpoint source control strategies on ambient water quality improvement. A greater portion of NPS load reduction in overall TMDL load reduction generally correlates with greater uncertainty and thus requires greater trading ratio. The rigorous quantification of trading ratio will enhance the scientific basis and thus public perception for more informed decision in overall watershed-based pollutant trading program. (c) IWA Publishing 2008.
Rational Design of Tunnel Supports: Tunnel Support Loading Caused by Rock Failure
1975-05-01
dotted lines connect points indicating the magnitude of the normal force within the liner. Middle; Same as above, but with floor beam ...and foremost to include some rotational freedom at beam element nodal points that correspond to connections between steel set segments as well as...subroutine SOL during the first support connection , with beam stiffnesses calculated in FORMB. 9. The tunnel periphery displacements that
Spacecraft solid state power distribution switch
NASA Technical Reports Server (NTRS)
Praver, G. A.; Theisinger, P. C.
1986-01-01
As a spacecraft performs its mission, various loads are connected to the spacecraft power bus in response to commands from an on board computer, a function called power distribution. For the Mariner Mark II set of planetary missions, the power bus is 30 volts dc and when loads are connected or disconnected, both the bus and power return side must be switched. In addition, the power distribution function must be immune to single point failures and, when power is first applied, all switches must be in a known state. Traditionally, these requirements have been met by electromechanical latching relays. This paper describes a solid state switch which not only satisfies the requirements but incorporates several additional features including soft turn on, programmable current trip point with noise immunity, instantaneous current limiting, and direct telemetry of load currents and switch status. A breadboard of the design has been constructed and some initial test results are included.
Neural network based optimal control of HVAC&R systems
NASA Astrophysics Data System (ADS)
Ning, Min
Heating, Ventilation, Air-Conditioning and Refrigeration (HVAC&R) systems have wide applications in providing a desired indoor environment for different types of buildings. It is well acknowledged that 30%-40% of the total energy generated is consumed by buildings and HVAC&R systems alone account for more than 50% of the building energy consumption. Low operational efficiency especially under partial load conditions and poor control are part of reasons for such high energy consumption. To improve energy efficiency, HVAC&R systems should be properly operated to maintain a comfortable and healthy indoor environment under dynamic ambient and indoor conditions with the least energy consumption. This research focuses on the optimal operation of HVAC&R systems. The optimization problem is formulated and solved to find the optimal set points for the chilled water supply temperature, discharge air temperature and AHU (air handling unit) fan static pressure such that the indoor environment is maintained with the least chiller and fan energy consumption. To achieve this objective, a dynamic system model is developed first to simulate the system behavior under different control schemes and operating conditions. The system model is modular in structure, which includes a water-cooled vapor compression chiller model and a two-zone VAV system model. A fuzzy-set based extended transformation approach is then applied to investigate the uncertainties of this model caused by uncertain parameters and the sensitivities of the control inputs with respect to the interested model outputs. A multi-layer feed forward neural network is constructed and trained in unsupervised mode to minimize the cost function which is comprised of overall energy cost and penalty cost when one or more constraints are violated. After training, the network is implemented as a supervisory controller to compute the optimal settings for the system. In order to implement the optimal set points predicted by the supervisory controller, a set of five adaptive PI (proportional-integral) controllers are designed for each of the five local control loops of the HVAC&R system. The five controllers are used to track optimal set points and zone air temperature set points. Parameters of these PI controllers are tuned online to reduce tracking errors. The updating rules are derived from Lyapunov stability analysis. Simulation results show that compared to the conventional night reset operation scheme, the optimal operation scheme saves around 10% energy under full load condition and 19% energy under partial load conditions.
NASA Technical Reports Server (NTRS)
Morris, C. E. K.; Tomaine, R. L.; Stevens, D. D.
1980-01-01
A flight investigation produced data on performance and rotor loads for a teetering rotor, AH-1G helicopter flown with a main rotor that had the NLR-1T airfoil as the blade section contour. The test envelope included hover, forward flight speeds from 34 to 83 m/sec (65 to 162 knots), and collective fixed maneuvers at about 0.25 tip speed ratio. The data set for each test point describes vehicle flight state, control positions, rotor loads, power requirements, and blade motions. Rotor loads are reviewed primarily in terms of peak to peak and harmonic content. Lower frequency components predominated for most loads and generally increased with increased airspeed, but not necessarily with increased maneuver load factor. Detailed data for an advanced airfoil on an AH-1G are presented.
de Manuel, Marc; Shiina, Takashi; Suzuki, Shingo; Dereuddre-Bosquet, Nathalie; Garchon, Henri-Jean; Tanaka, Masayuki; Congy-Jolivet, Nicolas; Aarnink, Alice; Le Grand, Roger; Marques-Bonet, Tomas; Blancher, Antoine
2018-05-08
In the Mauritian macaque experimentally inoculated with SIV, gene polymorphisms potentially associated with the plasma virus load at a set point, approximately 100 days post inoculation, were investigated. Among the 42 animals inoculated with 50 AID 50 of the same strain of SIV, none of which received any preventive or curative treatment, nine individuals were selected: three with a plasma virus load (PVL) among the lowest, three with intermediate PVL values and three among the highest PVL values. The complete genomes of these nine animals were then analyzed. Initially, attention was focused on variants with a potential functional impact on protein encoding genes (non-synonymous SNPs (NS-SNPs) and splicing variants). Thus, 424 NS-SNPs possibly associated with PVL were detected. The 424 candidates SNPs were genotyped in these 42 SIV experimentally infected animals (including the nine animals subjected to whole genome sequencing). The genes containing variants most probably associated with PVL at a set time point are analyzed herein.
A transmission-virulence evolutionary trade-off explains attenuation of HIV-1 in Uganda
Blanquart, François; Grabowski, Mary Kate; Herbeck, Joshua; Nalugoda, Fred; Serwadda, David; Eller, Michael A; Robb, Merlin L; Gray, Ronald; Kigozi, Godfrey; Laeyendecker, Oliver; Lythgoe, Katrina A; Nakigozi, Gertrude; Quinn, Thomas C; Reynolds, Steven J; Wawer, Maria J; Fraser, Christophe
2016-01-01
Evolutionary theory hypothesizes that intermediate virulence maximizes pathogen fitness as a result of a trade-off between virulence and transmission, but empirical evidence remains scarce. We bridge this gap using data from a large and long-standing HIV-1 prospective cohort, in Uganda. We use an epidemiological-evolutionary model parameterised with this data to derive evolutionary predictions based on analysis and detailed individual-based simulations. We robustly predict stabilising selection towards a low level of virulence, and rapid attenuation of the virus. Accordingly, set-point viral load, the most common measure of virulence, has declined in the last 20 years. Our model also predicts that subtype A is slowly outcompeting subtype D, with both subtypes becoming less virulent, as observed in the data. Reduction of set-point viral loads should have resulted in a 20% reduction in incidence, and a three years extension of untreated asymptomatic infection, increasing opportunities for timely treatment of infected individuals. DOI: http://dx.doi.org/10.7554/eLife.20492.001 PMID:27815945
A Workflow to Model Microbial Loadings in Watersheds ...
Many watershed models simulate overland and instream microbial fate and transport, but few actually provide loading rates on land surfaces and point sources to the water body network. This paper describes the underlying general equations for microbial loading rates associated with 1) land-applied manure on undeveloped areas from domestic animals; 2) direct shedding on undeveloped lands by domestic animals and wildlife; 3) urban or engineered areas; and 4) point sources that directly discharge to streams from septic systems and shedding by domestic animals. A microbial source module, which houses these formulations, is linked within a workflow containing eight models and a set of databases that form a loosely configured modeling infrastructure which supports watershed-scale microbial source-to-receptor modeling by focusing on animal-impacted catchments. A hypothetical example application – accessing, retrieving, and using real-world data – demonstrates the ability of the infrastructure to automate many of the manual steps associated with a standard watershed assessment, culminating with calibrated flow and microbial densities at the pour point of a watershed. Presented at 2016 Biennial Conference, International Environmental Modelling & Software Society.
Adjustable electronic load-alarm relay
Mason, Charles H.; Sitton, Roy S.
1976-01-01
This invention is an improved electronic alarm relay for monitoring the current drawn by an AC motor or other electrical load. The circuit is designed to measure the load with high accuracy and to have excellent alarm repeatability. Chattering and arcing of the relay contacts are minimal. The operator can adjust the set point easily and can re-set both the high and the low alarm points by means of one simple adjustment. The relay includes means for generating a signal voltage proportional to the motor current. In a preferred form of the invention a first operational amplifier is provided to generate a first constant reference voltage which is higher than a preselected value of the signal voltage. A second operational amplifier is provided to generate a second constant reference voltage which is lower than the aforementioned preselected value of the signal voltage. A circuit comprising a first resistor serially connected to a second resistor is connected across the outputs of the first and second amplifiers, and the junction of the two resistors is connected to the inverting terminal of the second amplifier. Means are provided to compare the aforementioned signal voltage with both the first and second reference voltages and to actuate an alarm if the signal voltage is higher than the first reference voltage or lower than the second reference voltage.
Long-term Changes in Water Quality and Productivity in the Patuxent River Estuary: 1985 to 2003
We conducted a quantitative assessment of estuarine ecosystem responses to reduced phosphorus and nitrogen loading from sewage treatment facilities and to variability in freshwater flow and non-point nutrient inputs to the Patuxent River estuary. We analyzed a 19-year data set o...
NASA Technical Reports Server (NTRS)
Katow, S. M.
1979-01-01
The computer analysis of the 34-m HA-DEC antenna by the IDEAS program provided the rms distortions of the surface panels support points for full gravity loadings in the three directions of the basic coordinate system of the computer model. The rms distortions for the gravity vector not in line with any of the three basic directions were solved and contour plotted starting from three surface panels setting declination angle. By inspections of the plots, it was concluded that the setting or rigging angle of -15 degrees declination minimized the rms distortions for sky coverage of plus or minus 22 declination angles to 10 degrees of ground mask.
Systems and Methods for Data Visualization Using Three-Dimensional Displays
NASA Technical Reports Server (NTRS)
Davidoff, Scott (Inventor); Djorgovski, Stanislav G. (Inventor); Estrada, Vicente (Inventor); Donalek, Ciro (Inventor)
2017-01-01
Data visualization systems and methods for generating 3D visualizations of a multidimensional data space are described. In one embodiment a 3D data visualization application directs a processing system to: load a set of multidimensional data points into a visualization table; create representations of a set of 3D objects corresponding to the set of data points; receive mappings of data dimensions to visualization attributes; determine the visualization attributes of the set of 3D objects based upon the selected mappings of data dimensions to 3D object attributes; update a visibility dimension in the visualization table for each of the plurality of 3D object to reflect the visibility of each 3D object based upon the selected mappings of data dimensions to visualization attributes; and interactively render 3D data visualizations of the 3D objects within the virtual space from viewpoints determined based upon received user input.
Gray, Clive M; Williamson, Carolyn; Bredell, Helba; Puren, Adrian; Xia, Xiaohua; Filter, Ruben; Zijenah, Lynn; Cao, Huyen; Morris, Lynn; Vardas, Efthyia; Colvin, Mark; Gray, Glenda; McIntyre, James; Musonda, Rosemary; Allen, Susan; Katzenstein, David; Mbizo, Mike; Kumwenda, Newton; Taha, Taha; Karim, Salim Abdool; Flores, Jorge; Sheppard, Haynes W
2005-04-01
Defining viral dynamics in natural infection is prognostic of disease progression and could prove to be important for vaccine trial design as viremia may be a likely secondary end point in phase III HIV efficacy trials. There are limited data available on the early course of plasma viral load in subtype C HIV-1 infection in Africa. Plasma viral load and CD4+ T cell counts were monitored in 51 recently infected subjects for 9 months. Individuals were recruited from four southern African countries: Zambia, Malawi, Zimbabwe, and South Africa and the median estimated time from seroconversion was 8.9 months (interquartile range, 5.7-14 months). All were infected with subtype C HIV-1 and median viral loads, measured using branched DNA, ranged from 3.82-4.02 log10 RNA copies/ml from 2-24 months after seroconversion. Viral loads significantly correlated with CD4+ cell counts (r=-0.5, p<0.0001; range, 376-364 cells/mm3) and mathematical modeling defined a median set point of 4.08 log10 (12 143 RNA copies/ml), which was attained approximately 17 months after seroconversion. Comparative measurements using three different viral load platforms (bDNA, Amplicor, and NucliSens) confirmed that viremia in subtype C HIV-1-infected individuals within the first 2 years of infection did not significantly differ from that found in early subtype B infection. In conclusion, the course of plasma viremia, as described in this study, will allow a useful baseline comparator for understanding disease progression in an African setting and may be useful in the design of HIV-1 vaccine trials in southern Africa.
Das, Saptarshi; Pan, Indranil; Das, Shantanu
2013-07-01
Fuzzy logic based PID controllers have been studied in this paper, considering several combinations of hybrid controllers by grouping the proportional, integral and derivative actions with fuzzy inferencing in different forms. Fractional order (FO) rate of error signal and FO integral of control signal have been used in the design of a family of decomposed hybrid FO fuzzy PID controllers. The input and output scaling factors (SF) along with the integro-differential operators are tuned with real coded genetic algorithm (GA) to produce optimum closed loop performance by simultaneous consideration of the control loop error index and the control signal. Three different classes of fractional order oscillatory processes with various levels of relative dominance between time constant and time delay have been used to test the comparative merits of the proposed family of hybrid fractional order fuzzy PID controllers. Performance comparison of the different FO fuzzy PID controller structures has been done in terms of optimal set-point tracking, load disturbance rejection and minimal variation of manipulated variable or smaller actuator requirement etc. In addition, multi-objective Non-dominated Sorting Genetic Algorithm (NSGA-II) has been used to study the Pareto optimal trade-offs between the set point tracking and control signal, and the set point tracking and load disturbance performance for each of the controller structure to handle the three different types of processes. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.
Using regression methods to estimate stream phosphorus loads at the Illinois River, Arkansas
Haggard, B.E.; Soerens, T.S.; Green, W.R.; Richards, R.P.
2003-01-01
The development of total maximum daily loads (TMDLs) requires evaluating existing constituent loads in streams. Accurate estimates of constituent loads are needed to calibrate watershed and reservoir models for TMDL development. The best approach to estimate constituent loads is high frequency sampling, particularly during storm events, and mass integration of constituents passing a point in a stream. Most often, resources are limited and discrete water quality samples are collected on fixed intervals and sometimes supplemented with directed sampling during storm events. When resources are limited, mass integration is not an accurate means to determine constituent loads and other load estimation techniques such as regression models are used. The objective of this work was to determine a minimum number of water-quality samples needed to provide constituent concentration data adequate to estimate constituent loads at a large stream. Twenty sets of water quality samples with and without supplemental storm samples were randomly selected at various fixed intervals from a database at the Illinois River, northwest Arkansas. The random sets were used to estimate total phosphorus (TP) loads using regression models. The regression-based annual TP loads were compared to the integrated annual TP load estimated using all the data. At a minimum, monthly sampling plus supplemental storm samples (six samples per year) was needed to produce a root mean square error of less than 15%. Water quality samples should be collected at least semi-monthly (every 15 days) in studies less than two years if seasonal time factors are to be used in the regression models. Annual TP loads estimated from independently collected discrete water quality samples further demonstrated the utility of using regression models to estimate annual TP loads in this stream system.
A Workflow to Model Microbial Loadings in Watersheds ...
Many watershed models simulate overland and instream microbial fate and transport, but few actually provide loading rates on land surfaces and point sources to the water body network. This paper describes the underlying general equations for microbial loading rates associated with 1) land-applied manure on undeveloped areas from domestic animals; 2) direct shedding on undeveloped lands by domestic animals and wildlife; 3) urban or engineered areas; and 4) point sources that directly discharge to streams from septic systems and shedding by domestic animals. A microbial source module, which houses these formulations, is linked within a workflow containing eight models and a set of databases that form a loosely configured modeling infrastructure which supports watershed-scale microbial source-to-receptor modeling by focusing on animal-impacted catchments. A hypothetical example application – accessing, retrieving, and using real-world data – demonstrates the ability of the infrastructure to automate many of the manual steps associated with a standard watershed assessment, culminating with calibrated flow and microbial densities at the pour point of a watershed. In the Proceedings of the International Environmental Modelling and Software Society (iEMSs), 8th International Congress on Environmental Modelling and Software, Toulouse, France
NASA Astrophysics Data System (ADS)
Vink, Rona; Behrendt, Horst
2002-11-01
Pollutant transport and management in the Rhine and Elbe basins is still of international concern, since certain target levels set by the international committees for protection of both rivers have not been reached. The analysis of the chain of emissions of point and diffuse sources to river loads will provide policy makers with a tool for effective management of river basins. The analysis of large river basins such as the Elbe and Rhine requires information on the spatial and temporal characteristics of both emissions and physical information of the entire river basin. In this paper, an analysis has been made of heavy metal emissions from various point and diffuse sources in the Rhine and Elbe drainage areas. Different point and diffuse pathways are considered in the model, such as inputs from industry, wastewater treatment plants, urban areas, erosion, groundwater, atmospheric deposition, tile drainage, and runoff. In most cases the measured heavy metal loads at monitoring stations are lower than the sum of the heavy metal emissions. This behaviour in large river systems can largely be explained by retention processes (e.g. sedimentation) and is dependent on the specific runoff of a catchment. Independent of the method used to estimate emissions, the source apportionment analysis of observed loads was used to determine the share of point and diffuse sources in the heavy metal load at a monitoring station by establishing a discharge dependency. The results from both the emission analysis and the source apportionment analysis of observed loads were compared and gave similar results. Between 51% (for Hg) and 74% (for Pb) of the total transport in the Elbe basin is supplied by inputs from diffuse sources. In the Rhine basin diffuse source inputs dominate the total transport and deliver more than 70% of the total transport. The diffuse hydrological pathways with the highest share are erosion and urban areas.
Gupta, Soham; Palchaudhuri, Riya; Neogi, Ujjwal; Srinivasa, Hiresave; Ashorn, Per; De Costa, Ayesha; Källander, Clas; Shet, Anita
2016-01-27
To evaluate the performance and cost of an HIV reverse transcriptase-enzyme activity (HIV-RT) assay in comparison to an HIV-1 RNA assay for routine viral load monitoring in resource limited settings. A cohort-based longitudinal study. Two antiretroviral therapy (ART) centres in Karnataka state, South India, providing treatment under the Indian AIDS control programme. A cohort of 327 HIV-1-infected Indian adult patients initiating first-line ART. Performance and cost of an HIV-RT assay (ExaVir Load V3) in comparison to a gold standard HIV-1 RNA assay (Abbott m2000rt) in a cohort of 327 Indian patients before (WK00) and 4 weeks (WK04) after initiation of first-line therapy. Plasma viral load was determined by an HIV-1 RNA assay and an HIV-RT assay in 629 samples (302 paired samples and 25 single time point samples at WK00) obtained from 327 patients. Overall, a strong correlation of r=0.96 was observed, with good correlation at WK00 (r=0.84) and at WK04 (r=0.77). Bland-Altman analysis of all samples showed a good level of agreement with a mean difference (bias) of 0.22 log10copies/mL. The performance of ExaVir Load V3 was not negatively affected by a nevirapine/efavirenz based antiretroviral regimen. The per test cost of measuring plasma viral load by the Abbott m2000rt and ExaVir Load V3 assays in a basic lab setting was $36.4 and $16.8, respectively. The strong correlation between the HIV-RT and HIV-1 RNA assays suggests that the HIV-RT assay can be an affordable alternative option for monitoring patients on antiretroviral therapy in resource-limited settings. ISRCTN79261738. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Machine Learning Techniques in Optimal Design
NASA Technical Reports Server (NTRS)
Cerbone, Giuseppe
1992-01-01
Many important applications can be formalized as constrained optimization tasks. For example, we are studying the engineering domain of two-dimensional (2-D) structural design. In this task, the goal is to design a structure of minimum weight that bears a set of loads. A solution to a design problem in which there is a single load (L) and two stationary support points (S1 and S2) consists of four members, E1, E2, E3, and E4 that connect the load to the support points is discussed. In principle, optimal solutions to problems of this kind can be found by numerical optimization techniques. However, in practice [Vanderplaats, 1984] these methods are slow and they can produce different local solutions whose quality (ratio to the global optimum) varies with the choice of starting points. Hence, their applicability to real-world problems is severely restricted. To overcome these limitations, we propose to augment numerical optimization by first performing a symbolic compilation stage to produce: (a) objective functions that are faster to evaluate and that depend less on the choice of the starting point and (b) selection rules that associate problem instances to a set of recommended solutions. These goals are accomplished by successive specializations of the problem class and of the associated objective functions. In the end, this process reduces the problem to a collection of independent functions that are fast to evaluate, that can be differentiated symbolically, and that represent smaller regions of the overall search space. However, the specialization process can produce a large number of sub-problems. This is overcome by deriving inductively selection rules which associate problems to small sets of specialized independent sub-problems. Each set of candidate solutions is chosen to minimize a cost function which expresses the tradeoff between the quality of the solution that can be obtained from the sub-problem and the time it takes to produce it. The overall solution to the problem, is then obtained by solving in parallel each of the sub-problems in the set and computing the one with the minimum cost. In addition to speeding up the optimization process, our use of learning methods also relieves the expert from the burden of identifying rules that exactly pinpoint optimal candidate sub-problems. In real engineering tasks it is usually too costly to the engineers to derive such rules. Therefore, this paper also contributes to a further step towards the solution of the knowledge acquisition bottleneck [Feigenbaum, 1977] which has somewhat impaired the construction of rulebased expert systems.
Modeling propellant-based stimulation of a borehole with peridynamics
Panchadhara, Rohan; Gordon, Peter A.; Parks, Michael L.
2017-02-27
A non-local formulation of classical continuum mechanics theory known as peridynamics is used to study fracture initiation and growth from a wellbore penetrating the subsurface within the context of propellant-based stimulation. The principal objectives of this work are to analyze the influence of loading conditions on the resulting fracture pattern, to investigate the effect of in-situ stress anisotropy on fracture propagation, and to assess the suitability of peridynamics for modeling complex fracture formation. In peridynamics, the momentum equation from the classical theory of solid mechanics is replaced by a non-local analogue, which results in an integrodifferential conservation equation. A continuummore » material is discretized with a set of material points that interact with all other points within a specified distance. Interactions between points are governed by bonds that can deform and break depending on loading conditions. The accumulated breakage of bonds gives rise to a picture of complex growth of fractures that is seen as a key advantage in the peridynamic representation of discontinuities. It is shown that the loading rate significantly influences the number and ex- tent of fractures initiated from a borehole. Results show that low loading rates produce fewer but longer fractures, whereas high loading rates produce numerous shorter fractures around the borehole. The numerical method is able to predict fracture growth patterns over a wide range of loading and stress conditions. Our results also show that fracture growth is attenuated with increasing in-situ confining stress, and, in the case of confining stress anisotropy, fracture extensions are largest in the direction perpendicular to the minimum compressive stress. Since the results are in broad qualitative agreement with experimental and numerical studies found in the literature, suggesting that peridynamics can be a powerful tool in the study of complex fracture network formation.« less
Modeling propellant-based stimulation of a borehole with peridynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Panchadhara, Rohan; Gordon, Peter A.; Parks, Michael L.
A non-local formulation of classical continuum mechanics theory known as peridynamics is used to study fracture initiation and growth from a wellbore penetrating the subsurface within the context of propellant-based stimulation. The principal objectives of this work are to analyze the influence of loading conditions on the resulting fracture pattern, to investigate the effect of in-situ stress anisotropy on fracture propagation, and to assess the suitability of peridynamics for modeling complex fracture formation. In peridynamics, the momentum equation from the classical theory of solid mechanics is replaced by a non-local analogue, which results in an integrodifferential conservation equation. A continuummore » material is discretized with a set of material points that interact with all other points within a specified distance. Interactions between points are governed by bonds that can deform and break depending on loading conditions. The accumulated breakage of bonds gives rise to a picture of complex growth of fractures that is seen as a key advantage in the peridynamic representation of discontinuities. It is shown that the loading rate significantly influences the number and ex- tent of fractures initiated from a borehole. Results show that low loading rates produce fewer but longer fractures, whereas high loading rates produce numerous shorter fractures around the borehole. The numerical method is able to predict fracture growth patterns over a wide range of loading and stress conditions. Our results also show that fracture growth is attenuated with increasing in-situ confining stress, and, in the case of confining stress anisotropy, fracture extensions are largest in the direction perpendicular to the minimum compressive stress. Since the results are in broad qualitative agreement with experimental and numerical studies found in the literature, suggesting that peridynamics can be a powerful tool in the study of complex fracture network formation.« less
Digital data used to relate nutrient inputs to water quality in the Chesapeake Bay watershed
Brakebill, John W.; Preston, Stephen D.
1999-01-01
Digital data sets were compiled by the U. S. Geological Survey (USGS) and used as input for a collection of Spatially Referenced Regressions On Watershed attributes for the Chesapeake Bay region. These regressions relate streamwater loads to nutrient sources and the factors that affect the transport of these nutrients throughout the watershed. A digital segmented network based on watershed boundaries serves as the primary foundation for spatially referencing total nitrogen and total phosphorus source and land-surface characteristic data sets within a Geographic Information System. Digital data sets of atmospheric wet deposition of nitrate, point-source discharge locations, land cover, and agricultural sources such as fertilizer and manure were created and compiled from numerous sources and represent nitrogen and phosphorus inputs. Some land-surface characteristics representing factors that affect the transport of nutrients include land use, land cover, average annual precipitation and temperature, slope, and soil permeability. Nutrient input and land-surface characteristic data sets merged with the segmented watershed network provide the spatial detail by watershed segment required by the models. Nutrient stream loads were estimated for total nitrogen, total phosphorus, nitrate/nitrite, amonium, phosphate, and total suspended soilds at as many as 109 sites within the Chesapeake Bay watershed. The total nitrogen and total phosphorus load estimates are the dependent variables for the regressions and were used for model calibration. Other nutrient-load estimates may be used for calibration in future applications of the models.
Assessment of Wind Parameter Sensitivity on Ultimate and Fatigue Wind Turbine Loads: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, Amy N; Sethuraman, Latha; Jonkman, Jason
Wind turbines are designed using a set of simulations to ascertain the structural loads that the turbine could encounter. While mean hub-height wind speed is considered to vary, other wind parameters such as turbulence spectra, sheer, veer, spatial coherence, and component correlation are fixed or conditional values that, in reality, could have different characteristics at different sites and have a significant effect on the resulting loads. This paper therefore seeks to assess the sensitivity of different wind parameters on the resulting ultimate and fatigue loads on the turbine during normal operational conditions. Eighteen different wind parameters are screened using anmore » Elementary Effects approach with radial points. As expected, the results show a high sensitivity of the loads to the turbulence standard deviation in the primary wind direction, but the sensitivity to wind shear is often much greater. To a lesser extent, other wind parameters that drive loads include the coherence in the primary wind direction and veer.« less
Assessment of Wind Parameter Sensitivity on Extreme and Fatigue Wind Turbine Loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, Amy N; Sethuraman, Latha; Jonkman, Jason
Wind turbines are designed using a set of simulations to ascertain the structural loads that the turbine could encounter. While mean hub-height wind speed is considered to vary, other wind parameters such as turbulence spectra, sheer, veer, spatial coherence, and component correlation are fixed or conditional values that, in reality, could have different characteristics at different sites and have a significant effect on the resulting loads. This paper therefore seeks to assess the sensitivity of different wind parameters on the resulting ultimate and fatigue loads on the turbine during normal operational conditions. Eighteen different wind parameters are screened using anmore » Elementary Effects approach with radial points. As expected, the results show a high sensitivity of the loads to the turbulence standard deviation in the primary wind direction, but the sensitivity to wind shear is often much greater. To a lesser extent, other wind parameters that drive loads include the coherence in the primary wind direction and veer.« less
40 CFR 63.11527 - What are the monitoring requirements for new and existing sources?
Code of Federal Regulations, 2011 CFR
2011-07-01
... alarm that will sound when an increase in relative PM loadings is detected over the alarm set point... operating a bag leak detection system, if an alarm sounds, conduct visual monitoring of the monovent or... maintain a continuous parameter monitoring system (CPMS) to measure and record the 3-hour average pressure...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Woohyun; Katipamula, Srinivas; Lutes, Robert G.
This report describes how the intelligent load control (ILC) algorithm can be implemented to achieve peak demand reduction while minimizing impacts on occupant comfort. The algorithm was designed to minimize the additional sensors and minimum configuration requirements to enable a scalable and cost-effective implementation for both large and small-/medium-sized commercial buildings. The ILC algorithm uses an analytic hierarchy process (AHP) to dynamically prioritize the available curtailable loads based on both quantitative (deviation of zone conditions from set point) and qualitative rules (types of zone). Although the ILC algorithm described in this report was highly tailored to work with rooftop units,more » it can be generalized for application to other building loads such as variable-air-volume (VAV) boxes and lighting systems.« less
A General Simulation Method for Multiple Bodies in Proximate Flight
NASA Technical Reports Server (NTRS)
Meakin, Robert L.
2003-01-01
Methods of unsteady aerodynamic simulation for an arbitrary number of independent bodies flying in close proximity are considered. A novel method to efficiently detect collision contact points is described. A method to compute body trajectories in response to aerodynamic loads, applied loads, and inter-body collisions is also given. The physical correctness of the methods are verified by comparison to a set of analytic solutions. The methods, combined with a Navier-Stokes solver, are used to demonstrate the possibility of predicting the unsteady aerodynamics and flight trajectories of moving bodies that involve rigid-body collisions.
Endotoxins in indoor air and settled dust in primary schools in a subtropical climate.
Salonen, Heidi; Duchaine, Caroline; Létourneau, Valérie; Mazaheri, Mandana; Clifford, Sam; Morawska, Lidia
2013-09-03
Endotoxins can significantly affect the air quality in school environments. However, there is currently no reliable method for the measurement of endotoxins, and there is a lack of reference values for endotoxin concentrations to aid in the interpretation of measurement results in school settings. We benchmarked the "baseline" range of endotoxin concentration in indoor air, together with endotoxin load in floor dust, and evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings. Bayesian hierarchical modeling indicated that the concentration in indoor air and the load in floor dust were generally (<95th percentile) <13 EU/m(3) and <24,570 EU/m(2), respectively. Exceeding these levels would indicate abnormal sources of endotoxins in the school environment and the need for further investigation. Metaregression indicated no relationship between endotoxin concentration and load, which points to the necessity for measuring endotoxin levels in both the air and settled dust. Temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust. Higher levels of humidity may be associated with lower airborne endotoxin concentrations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haves, Phillip; Hencey, Brandon; Borrell, Francesco
2010-06-29
A Model Predictive Control algorithm was developed for the UC Merced campus chilled water plant. Model predictive control (MPC) is an advanced control technology that has proven successful in the chemical process industry and other industries. The main goal of the research was to demonstrate the practical and commercial viability of MPC for optimization of building energy systems. The control algorithms were developed and implemented in MATLAB, allowing for rapid development, performance, and robustness assessment. The UC Merced chilled water plant includes three water-cooled chillers and a two million gallon chilled water storage tank. The tank is charged during themore » night to minimize on-peak electricity consumption and take advantage of the lower ambient wet bulb temperature. The control algorithms determined the optimal chilled water plant operation including chilled water supply (CHWS) temperature set-point, condenser water supply (CWS) temperature set-point and the charging start and stop times to minimize a cost function that includes energy consumption and peak electrical demand over a 3-day prediction horizon. A detailed model of the chilled water plant and simplified models of the buildings served by the plant were developed using the equation-based modeling language Modelica. Steady state models of the chillers, cooling towers and pumps were developed, based on manufacturers performance data, and calibrated using measured data collected and archived by the control system. A detailed dynamic model of the chilled water storage tank was also developed and calibrated. Simple, semi-empirical models were developed to predict the temperature and flow rate of the chilled water returning to the plant from the buildings. These models were then combined and simplified for use in a model predictive control algorithm that determines the optimal chiller start and stop times and set-points for the condenser water temperature and the chilled water supply temperature. The report describes the development and testing of the algorithm and evaluates the resulting performance, concluding with a discussion of next steps in further research. The experimental results show a small improvement in COP over the baseline policy but it is difficult to draw any strong conclusions about the energy savings potential for MPC with this system only four days of suitable experimental data were obtained once correct operation of the MPC system had been achieved. These data show an improvement in COP of 3.1% {+-} 2.2% relative to a baseline established immediately prior to the period when the MPC was run in its final form. This baseline includes control policy improvements that the plant operators learned by observing the earlier implementations of MPC, including increasing the temperature of the water supplied to the chiller condensers from the cooling towers. The process of data collection and model development, necessary for any MPC project, resulted in the team uncovering various problems with the chilled water system. Although it is difficult to quantify the energy savings resulting from these problems being remedied, they were likely on the same order as the energy savings from the MPC itself. Although the types of problems uncovered and the level of energy savings may differ significantly from other projects, some of the benefits of detecting and diagnosing problems are expected from the use of MPC for any chilled water plant. The degree of chiller loading was found to be a key factor for efficiency. It is more efficient to operate the chillers at or near full load. In order to maximize the chiller load, one would maximize the temperature difference across chillers and the chilled water flow rate through the chillers. Thus, the CHWS set-point and the chilled water flow-rate can be used to limit the chiller loading to prevent chiller surging. Since the flow rate has an upper bound and the CHWS set point has a lower bound, the chiller loading is constrained and often determined by the chilled water return temperature (CHWR). The CHWR temperature is primarily comprised of warm water from the top of the TES tank. The CHWR temperature falls substantially as the thermocline approaches the top of the tank, which reduces the chiller loading. As a result, it has been determined that overcharging the TES tank can be detrimental to the chilled water plant efficiency. The resulting MPC policy differs from the current practice of fully charging the TES tank. A heuristic rule could possible avoid this problem without using predictive control. Similarly, the COP improvements from the change in CWS set-point were largely captured by a static set-point change by the operators. Further research is required to determine how much of the MPC savings could be garnered through simplified rules (based on the MPC study), with and without prediction.« less
Re-Evaluation of Development of the TMDL Using Long-Term Monitoring Data and Modeling
NASA Astrophysics Data System (ADS)
Squires, A.; Rittenburg, R.; Boll, J.; Brooks, E. S.
2012-12-01
Since 1996, 47,979 Total Maximum Daily Loads (TMDLs) have been approved throughout the United States for impaired water bodies. TMDLs are set through the determination of natural background loads for a given water body which then estimate contributions from point and nonpoint sources to create load allocations and determine acceptable pollutant levels to meet water quality standards. Monitoring data and hydrologic models may be used in this process. However, data sets used are often limited in duration and frequency, and model simulations are not always accurate. The objective of this study is to retrospectively look at the development and accuracy of the TMDL for a stream in an agricultural area using long-term monitoring data and a robust modeling process. The study area is the Paradise Creek Watershed in northern Idaho. A sediment TMDL was determined for the Idaho section of Paradise Creek in 1997. Sediment TMDL levels were determined using a short-term data set and the Water Erosion Prediction Project (WEPP) model. Background loads used for the TMDL in 1997 were from pre-agricultural levels, based on WEPP model results. We modified the WEPP model for simulation of saturation excess overland flow, the dominant runoff generation mechanism, and analyzed more than 10 years of high resolution monitoring data from 2001 - 2012, including discharge and total suspended solids. Results will compare background loading and current loading based on present-day land use documented during the monitoring period and compare previous WEPP model results with the modified WEPP model results. This research presents a reevaluation of the TMDL process with recommendations for a more scientifically sound methodology to attain realistic water quality goals.
Changing Regulations of COD Pollution Load of Weihe River Watershed above TongGuan Section, China
NASA Astrophysics Data System (ADS)
Zhu, Lei; Liu, WanQing
2018-02-01
TongGuan Section of Weihe River Watershed is a provincial section between Shaanxi Province and Henan Province, China. Weihe River Watershed above TongGuan Section is taken as the research objective in this paper and COD is chosen as the water quality parameter. According to the discharge characteristics of point source pollutions and non-point source pollutions, a method—characteristic section load (CSLD) method is suggested and point and non-point source pollution loads of Weihe River Watershed above TongGuan Section are calculated in the rainy, normal and dry season in 2013. The results show that the monthly point source pollution loads of Weihe River Watershed above TongGuan Section discharge stably and the monthly non-point source pollution loads of Weihe River Watershed above TongGuan Section change greatly and the non-point source pollution load proportions of total pollution load of COD decrease in the rainy, wet and normal period in turn.
NASA Astrophysics Data System (ADS)
Zhu, Lei; Song, JinXi; Liu, WanQing
2017-12-01
Huaxian Section is the last hydrological and water quality monitoring section of Weihe River Watershed. Weihe River Watershed above Huaxian Section is taken as the research objective in this paper and COD is chosen as the water quality parameter. According to the discharge characteristics of point source pollutions and non-point source pollutions, a new method to estimate pollution loads—characteristic section load(CSLD) method is suggested and point source pollution and non-point source pollution loads of Weihe River Watershed above Huaxian Section are calculated in the rainy, normal and dry season in the year 2007. The results show that the monthly point source pollution loads of Weihe River Watershed above Huaxian Section discharge stably and the monthly non-point source pollution loads of Weihe River Watershed above Huaxian Section change greatly and the non-point source pollution load proportions of total pollution load of COD decrease in the normal, rainy and wet period in turn.
Calculating NH3-N pollution load of wei river watershed above Huaxian section using CSLD method
NASA Astrophysics Data System (ADS)
Zhu, Lei; Song, JinXi; Liu, WanQing
2018-02-01
Huaxian Section is the last hydrological and water quality monitoring section of Weihe River Watershed. So it is taken as the research objective in this paper and NH3-N is chosen as the water quality parameter. According to the discharge characteristics of point source pollutions and non-point source pollutions, a new method to estimate pollution loads—characteristic section load (CSLD)method is suggested and point source pollution and non-point source pollution loads of Weihe River Watershed above Huaxian Section are calculated in the rainy, normal and dry season in the year 2007. The results show that the monthly point source pollution loads of Weihe River Watershed above Huaxian Section discharge stably and the monthly non-point source pollution loads of Weihe River Watershed above Huaxian Section change greatly. The non-point source pollution load proportions of total pollution load of NH3-N decrease in the normal, rainy and wet period in turn.
NASA Technical Reports Server (NTRS)
Solis, Eduardo; Meyn, Larry
2016-01-01
Calibrating the internal, multi-component balance mounted in the Tiltrotor Test Rig (TTR) required photogrammetric measurements to determine the location and orientation of forces applied to the balance. The TTR, with the balance and calibration hardware attached, was mounted in a custom calibration stand. Calibration loads were applied using eleven hydraulic actuators, operating in tension only, that were attached to the forward frame of the calibration stand and the TTR calibration hardware via linkages with in-line load cells. Before the linkages were installed, photogrammetry was used to determine the location of the linkage attachment points on the forward frame and on the TTR calibration hardware. Photogrammetric measurements were used to determine the displacement of the linkage attachment points on the TTR due to deflection of the hardware under applied loads. These measurements represent the first photogrammetric deflection measurements to be made to support 6-component rotor balance calibration. This paper describes the design of the TTR and the calibration hardware, and presents the development, set-up and use of the photogrammetry system, along with some selected measurement results.
NASA Astrophysics Data System (ADS)
Avci, Mesut
A practical cost and energy efficient model predictive control (MPC) strategy is proposed for HVAC load control under dynamic real-time electricity pricing. The MPC strategy is built based on a proposed model that jointly minimizes the total energy consumption and hence, cost of electricity for the user, and the deviation of the inside temperature from the consumer's preference. An algorithm that assigns temperature set-points (reference temperatures) to price ranges based on the consumer's discomfort tolerance index is developed. A practical parameter prediction model is also designed for mapping between the HVAC load and the inside temperature. The prediction model and the produced temperature set-points are integrated as inputs into the MPC controller, which is then used to generate signal actions for the AC unit. To investigate and demonstrate the effectiveness of the proposed approach, a simulation based experimental analysis is presented using real-life pricing data. An actual prototype for the proposed HVAC load control strategy is then built and a series of prototype experiments are conducted similar to the simulation studies. The experiments reveal that the MPC strategy can lead to significant reductions in overall energy consumption and cost savings for the consumer. Results suggest that by providing an efficient response strategy for the consumers, the proposed MPC strategy can enable the utility providers to adopt efficient demand management policies using real-time pricing. Finally, a cost-benefit analysis is performed to display the economic feasibility of implementing such a controller as part of a building energy management system, and the payback period is identified considering cost of prototype build and cost savings to help the adoption of this controller in the building HVAC control industry.
Wininger, Fred A; Kapatkin, Amy S; Radin, Alex; Shofer, Frances S; Smith, Gail K
2007-12-01
To compare failure mode and bending moment of a canine pancarpal arthrodesis construct using either a 2.7 mm/3.5 mm hybrid dynamic compression plate (HDCP) or a 3.5 mm dynamic compression plate (DCP). Paired in vitro biomechanical testing of canine pancarpal arthrodesis constructs stabilized with either a 2.7/3.5 HDCP or 3.5 DCP. Paired cadaveric canine antebrachii (n=5). Pancarpal arthrodesis constructs were loaded to failure (point of maximum load) in 4-point bending using a materials-testing machine. Using this point of failure, bending moments were calculated from system variables for each construct and the 2 plating systems compared using a paired t-test. To examine the relationship between metacarpal diameter and screw diameter failure loads, linear regression was used and Pearson' correlation coefficient was calculated. Significance was set at P<.05. HDCP failed at higher loads than DCP for 9 of 10 constructs. The absolute difference in failure rates between the 2 plates was 0.552+/-0.182 N m, P=.0144 (95% confidence interval: -0.58 to 1.68). This is an 8.1% mean difference in bending strength. There was a significant linear correlation r=0.74 (P-slope=.014) and 0.8 (P-slope=.006) between metacarpal diameter and failure loads for the HDCP and 3.5 DCP, respectively. There was a small but significant difference between bending moment at failure between 2.7/3.5 HDCP and 3.5 DCP constructs; however, the difference may not be clinically evident in all patients. The 2.7/3.5 HDCP has physical and mechanical properties making it a more desirable plate for pancarpal arthrodesis.
Determination of stores pointing error due to wing flexibility under flight load
NASA Technical Reports Server (NTRS)
Lokos, William A.; Bahm, Catherine M.; Heinle, Robert A.
1995-01-01
The in-flight elastic wing twist of a fighter-type aircraft was studied to provide for an improved on-board real-time computed prediction of pointing variations of three wing store stations. This is an important capability to correct sensor pod alignment variation or to establish initial conditions of iron bombs or smart weapons prior to release. The original algorithm was based upon coarse measurements. The electro-optical Flight Deflection Measurement System measured the deformed wing shape in flight under maneuver loads to provide a higher resolution database from which an improved twist prediction algorithm could be developed. The FDMS produced excellent repeatable data. In addition, a NASTRAN finite-element analysis was performed to provide additional elastic deformation data. The FDMS data combined with the NASTRAN analysis indicated that an improved prediction algorithm could be derived by using a different set of aircraft parameters, namely normal acceleration, stores configuration, Mach number, and gross weight.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shetulov, D. I.; Andreev, V. V., E-mail: vyach.andreev@mail.ru; Myasnikov, A. M.
Most of the destructions of machine parts are of fatigue character. Under cyclic loading, the surface layer, in which hardening–softening processes rapidly occur, is formed almost at once after its beginning. The interaction of plastic-deformation traces with each other and with other structural elements, such as grains, results in the formation of a characteristic microstructure of the machine-part surface subject to cyclic loadings. The character of accumulation of slip bands and their shape (narrow, wide, twisting, and broken) depends on the conditions under which (under what factors) the cyclic loading occurs. The fatigue-resistance index expressed in terms of the slopemore » of left portion of the fatigue curve linearized in logarithmic coordinates also depends on the set of relevant factors. The dependence of the surface damageability on the fatigue resistance index makes it possible to implement the method of predicting the fatigue curve by the description of the factors acting on a detail or construction. The position of the inflection point on the curve in the highcycle fatigue region (the endurance limit and the number of loading cycles, the ordinate and abscissa of the inflection point on the fatigue curve, respectively) also depends on the set of relevant factors. In combination with the previously obtained value of the slope of the left portion of the curve in the high-cycle fatigue region, this makes it possible to construct an a priori fatigue curve, thus reducing the scope of required fatigue tests and, hence, high expenses because of their long duration and high cost. The scope of tests upon using the developed method of prediction may be reduced to a minimum of one or two samples at the predicted level of the endurance limit.« less
Avionics for a Small Satellite
NASA Technical Reports Server (NTRS)
Abbott, Larry; Jochim, David; Schuler, Robert
2001-01-01
This paper discusses a small. seven and a half (7.5) inch diameter. satellite that NASA-JSC is developing as a technology demonstrator for an astronaut assistant free flyer. The Free Flyer is designed to off load flight crew work load by performing inspections of the exterior of Space Shuttle or International Space Station. The Free Flyer is designed to be operated by the flight crew thereby reducing the number of Extra Vehicle Activities (EVA) or by an astronaut on the ground further reducing crew work load. The paper focuses on the design constraint of a small satellite and the technology approach used to achieve the set of high performance requirements specified for the Free Flyer. Particular attention is paid to the processor card as it is the heart and system integration point of the Free Flyer.
Polsky, Yarom
2014-05-23
This entry contains raw data files from experiments performed on the Vulcan beamline at the Spallation Neutron Source at Oak Ridge National Laboratory using a pressure cell. Cylindrical granite and marble samples were subjected to confining pressures of either 0 psi or approximately 2500 psi and internal pressures of either 0 psi, 1500 psi or 2500 psi through a blind axial hole at the center of one end of the sample. The sample diameters were 1.5" and the sample lengths were 6". The blind hole was 0.25" in diameter and 3" deep. One set of experiments measured strains at points located circumferentially around the center of the sample with identical radii to determine if there was strain variability (this would not be expected for a homogeneous material based on the symmetry of loading). Another set of experiments measured load variation across the radius of the sample at a fixed axial and circumferential location. Raw neutron diffraction intensity files and experimental parameter descriptions are included.
Tools for Early Prediction of Drug Loading in Lipid-Based Formulations
2015-01-01
Identification of the usefulness of lipid-based formulations (LBFs) for delivery of poorly water-soluble drugs is at date mainly experimentally based. In this work we used a diverse drug data set, and more than 2,000 solubility measurements to develop experimental and computational tools to predict the loading capacity of LBFs. Computational models were developed to enable in silico prediction of solubility, and hence drug loading capacity, in the LBFs. Drug solubility in mixed mono-, di-, triglycerides (Maisine 35-1 and Capmul MCM EP) correlated (R2 0.89) as well as the drug solubility in Carbitol and other ethoxylated excipients (PEG400, R2 0.85; Polysorbate 80, R2 0.90; Cremophor EL, R2 0.93). A melting point below 150 °C was observed to result in a reasonable solubility in the glycerides. The loading capacity in LBFs was accurately calculated from solubility data in single excipients (R2 0.91). In silico models, without the demand of experimentally determined solubility, also gave good predictions of the loading capacity in these complex formulations (R2 0.79). The framework established here gives a better understanding of drug solubility in single excipients and of LBF loading capacity. The large data set studied revealed that experimental screening efforts can be rationalized by solubility measurements in key excipients or from solid state information. For the first time it was shown that loading capacity in complex formulations can be accurately predicted using molecular information extracted from calculated descriptors and thermal properties of the crystalline drug. PMID:26568134
Tools for Early Prediction of Drug Loading in Lipid-Based Formulations.
Alskär, Linda C; Porter, Christopher J H; Bergström, Christel A S
2016-01-04
Identification of the usefulness of lipid-based formulations (LBFs) for delivery of poorly water-soluble drugs is at date mainly experimentally based. In this work we used a diverse drug data set, and more than 2,000 solubility measurements to develop experimental and computational tools to predict the loading capacity of LBFs. Computational models were developed to enable in silico prediction of solubility, and hence drug loading capacity, in the LBFs. Drug solubility in mixed mono-, di-, triglycerides (Maisine 35-1 and Capmul MCM EP) correlated (R(2) 0.89) as well as the drug solubility in Carbitol and other ethoxylated excipients (PEG400, R(2) 0.85; Polysorbate 80, R(2) 0.90; Cremophor EL, R(2) 0.93). A melting point below 150 °C was observed to result in a reasonable solubility in the glycerides. The loading capacity in LBFs was accurately calculated from solubility data in single excipients (R(2) 0.91). In silico models, without the demand of experimentally determined solubility, also gave good predictions of the loading capacity in these complex formulations (R(2) 0.79). The framework established here gives a better understanding of drug solubility in single excipients and of LBF loading capacity. The large data set studied revealed that experimental screening efforts can be rationalized by solubility measurements in key excipients or from solid state information. For the first time it was shown that loading capacity in complex formulations can be accurately predicted using molecular information extracted from calculated descriptors and thermal properties of the crystalline drug.
Composite power system well-being analysis
NASA Astrophysics Data System (ADS)
Aboreshaid, Saleh Abdulrahman Saleh
The evaluation of composite system reliability is extremely complex as it is necessary to include detailed modeling of both generation and transmission facilities and their auxiliary elements. The most significant quantitative indices in composite power system adequacy evaluation are those which relate to load curtailment. Many utilities have difficulty in interpreting the expected load curtailment indices as the existing models are based on adequacy analysis and in many cases do not consider realistic operating conditions in the system under study. This thesis presents a security based approach which alleviates this difficulty and provides the ability to evaluate the well-being of customer load points and the overall composite generation and transmission power system. Acceptable deterministic criteria are included in the probabilistic evaluation of the composite system reliability indices to monitor load point well-being. The degree of load point well-being is quantified in terms of the healthy and marginal state indices in addition to the traditional risk indices. The individual well-being indices of the different system load points are aggregated to produce system indices. This thesis presents new models and techniques to quantify the well-being of composite generation and, direct and alternating current transmission systems. Security constraints are basically the operating limits which must be satisfied for normal system operation. These constraints depend mainly on the purpose behind the study. The constraints which govern the practical operation of a power system are divided, in this thesis, into three sets namely, steady-state, voltage stability and transient stability constraints. The inclusion of an appropriate transient stability constraint will lead to a more accurate appraisal of the overall power system well-being. This thesis illustrates the utilization of a bisection method in the analytical evaluation of the critical clearing time which forms the basis of most existing stability assessments. The effect of employing high-speed-simultaneous or adaptive reclosing schemes is presented in this thesis. An effective and fast technique to incorporate voltage stability considerations in composite generation and transmission system reliability evaluation is also presented. The proposed technique can be easily incorporated in an existing composite power system reliability program using voltage stability constraints that are constructed for individual load points based on a relatively simple risk index. It is believed that the concepts, procedures and indices presented in this thesis will provide useful tools for power system designers, planners and operators and assist them to perform composite system well-being analysis in addition to traditional risk assessment.
Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger
NASA Technical Reports Server (NTRS)
Ungar, Eugene K.; Schunk, Richard G.
2011-01-01
An active thermal control system architecture has been modified to include a regenerative heat exchanger (regenerator) inboard of the radiator. Rather than using a radiator bypass valve a regenerative heat exchanger is placed inboard of the radiators. A regenerator cold side bypass valve is used to set the return temperature. During operation, the regenerator bypass flow is varied, mixing cold radiator return fluid and warm regenerator outlet fluid to maintain the system setpoint. At the lowest heat load for stable operation, the bypass flow is closed off, sending all of the flow through the regenerator. This lowers the radiator inlet temperature well below the system set-point while maintaining full flow through the radiators. By using a regenerator bypass flow control to maintain system setpoint, the required minimum heat load to avoid radiator freezing can be reduced by more than half compared to a radiator bypass system.
Optimizing Maintenance of Constraint-Based Database Caches
NASA Astrophysics Data System (ADS)
Klein, Joachim; Braun, Susanne
Caching data reduces user-perceived latency and often enhances availability in case of server crashes or network failures. DB caching aims at local processing of declarative queries in a DBMS-managed cache close to the application. Query evaluation must produce the same results as if done at the remote database backend, which implies that all data records needed to process such a query must be present and controlled by the cache, i. e., to achieve “predicate-specific” loading and unloading of such record sets. Hence, cache maintenance must be based on cache constraints such that “predicate completeness” of the caching units currently present can be guaranteed at any point in time. We explore how cache groups can be maintained to provide the data currently needed. Moreover, we design and optimize loading and unloading algorithms for sets of records keeping the caching units complete, before we empirically identify the costs involved in cache maintenance.
Prospective Study of Acute HIV-1 Infection in Adults in East Africa and Thailand
Robb, Merlin L.; Eller, Leigh A.; Kibuuka, Hannah; Rono, Kathleen; Maganga, Lucas; Nitayaphan, Sorachai; Kroon, Eugene; Sawe, Fred K.; Sinei, Samuel; Sriplienchan, Somchai; Jagodzinski, Linda L.; Malia, Jennifer; Manak, Mark; de Souza, Mark S.; Tovanabutra, Sodsai; Sanders-Buell, Eric; Rolland, Morgane; Dorsey-Spitz, Julie; Eller, Michael A.; Milazzo, Mark; Li, Qun; Lewandowski, Andrew; Wu, Hao; Swann, Edith; O'Connell, Robert J.; Peel, Sheila; Dawson, Peter; Kim, Jerome H.; Michael, Nelson L.
2016-01-01
Background Acute human immunodeficiency virus type 1 (HIV-1) infection is a major contributor to transmission of HIV-1. An understanding of acute HIV-1 infection may be important in the development of treatment strategies to eradicate HIV-1 or achieve a functional cure. Methods We performed twice-weekly qualitative plasma HIV-1 RNA nucleic acid testing in 2276 volunteers who were at high risk for HIV-1 infection. For participants in whom acute HIV-1 infection was detected, clinical observations, quantitative measurements of plasma HIV-1 RNA levels (to assess viremia) and HIV antibodies, and results of immunophenotyping of lymphocytes were obtained twice weekly. Results Fifty of 112 volunteers with acute HIV-1 infection had two or more blood samples collected before HIV-1 antibodies were detected. The median peak viremia (6.7 log10 copies per milliliter) occurred 13 days after the first sample showed reactivity on nucleic acid testing. Reactivity on an enzyme immunoassay occurred at a median of 14 days. The nadir of viremia (4.3 log10 copies per milliliter) occurred at a median of 31 days and was nearly equivalent to the viral-load set point, the steady-state viremia that persists durably after resolution of acute viremia (median plasma HIV-1 RNA level, 4.4 log10 copies per milliliter). The peak viremia and downslope were correlated with the viral-load set point. Clinical manifestations of acute HIV-1 infection were most common just before and at the time of peak viremia. A median of one symptom of acute HIV-1 infection was recorded at a median of two study visits, and a median of one sign of acute HIV-1 infection was recorded at a median of three visits. Conclusions The viral-load set point occurred at a median of 31 days after the first detection of plasma viremia and correlated with peak viremia. Few symptoms and signs were observed during acute HIV-1 infection, and they were most common before peak viremia. (Funded by the Department of Defense and the National Institute of Allergy and Infectious Diseases.) PMID:27192360
Prospective Study of Acute HIV-1 Infection in Adults in East Africa and Thailand.
Robb, Merlin L; Eller, Leigh A; Kibuuka, Hannah; Rono, Kathleen; Maganga, Lucas; Nitayaphan, Sorachai; Kroon, Eugene; Sawe, Fred K; Sinei, Samuel; Sriplienchan, Somchai; Jagodzinski, Linda L; Malia, Jennifer; Manak, Mark; de Souza, Mark S; Tovanabutra, Sodsai; Sanders-Buell, Eric; Rolland, Morgane; Dorsey-Spitz, Julie; Eller, Michael A; Milazzo, Mark; Li, Qun; Lewandowski, Andrew; Wu, Hao; Swann, Edith; O'Connell, Robert J; Peel, Sheila; Dawson, Peter; Kim, Jerome H; Michael, Nelson L
2016-06-02
Acute human immunodeficiency virus type 1 (HIV-1) infection is a major contributor to transmission of HIV-1. An understanding of acute HIV-1 infection may be important in the development of treatment strategies to eradicate HIV-1 or achieve a functional cure. We performed twice-weekly qualitative plasma HIV-1 RNA nucleic acid testing in 2276 volunteers who were at high risk for HIV-1 infection. For participants in whom acute HIV-1 infection was detected, clinical observations, quantitative measurements of plasma HIV-1 RNA levels (to assess viremia) and HIV antibodies, and results of immunophenotyping of lymphocytes were obtained twice weekly. Fifty of 112 volunteers with acute HIV-1 infection had two or more blood samples collected before HIV-1 antibodies were detected. The median peak viremia (6.7 log10 copies per milliliter) occurred 13 days after the first sample showed reactivity on nucleic acid testing. Reactivity on an enzyme immunoassay occurred at a median of 14 days. The nadir of viremia (4.3 log10 copies per milliliter) occurred at a median of 31 days and was nearly equivalent to the viral-load set point, the steady-state viremia that persists durably after resolution of acute viremia (median plasma HIV-1 RNA level, 4.4 log10 copies per milliliter). The peak viremia and downslope were correlated with the viral-load set point. Clinical manifestations of acute HIV-1 infection were most common just before and at the time of peak viremia. A median of one symptom of acute HIV-1 infection was recorded at a median of two study visits, and a median of one sign of acute HIV-1 infection was recorded at a median of three visits. The viral-load set point occurred at a median of 31 days after the first detection of plasma viremia and correlated with peak viremia. Few symptoms and signs were observed during acute HIV-1 infection, and they were most common before peak viremia. (Funded by the Department of Defense and the National Institute of Allergy and Infectious Diseases.).
Stamer, J.K.; Cherry, R.N.; Faye, R.E.; Kleckner, R.L.
1978-01-01
On an average annual basis and during the storm period of March 12-15, 1976, nonpoint-source loads for most constituents were larger than point-source loads at the Whitesburg station, located on the Chattahoochee River about 40 miles downstream from Atlanta, GA. Most of the nonpoint-source constituent loads in the Atlanta to Whitesburg reach were from urban areas. Average annual point-source discharges accounted for about 50 percent of the dissolved nitrogen, total nitrogen, and total phosphorus loads and about 70 percent of the dissolved phosphorus loads at Whitesburg. During a low-flow period, June 1-2, 1977, five municipal point-sources contributed 63 percent of the ultimate biochemical oxygen demand, and 97 percent of the ammonium nitrogen loads at the Franklin station, at the upstream end of West Point Lake. Dissolved-oxygen concentrations of 4.1 to 5.0 milligrams per liter occurred in a 22-mile reach of the river downstream from Atlanta due about equally to nitrogenous and carbonaceous oxygen demands. The heat load from two thermoelectric powerplants caused a decrease in dissolved-oxygen concentration of about 0.2 milligrams per liter. Phytoplankton concentrations in West Point Lake, about 70 miles downstream from Atlanta, could exceed three million cells per millimeter during extended low-flow periods in the summer with present point-source phosphorus loads. (Woodard-USGS)
Wind Tunnel Strain-Gage Balance Calibration Data Analysis Using a Weighted Least Squares Approach
NASA Technical Reports Server (NTRS)
Ulbrich, N.; Volden, T.
2017-01-01
A new approach is presented that uses a weighted least squares fit to analyze wind tunnel strain-gage balance calibration data. The weighted least squares fit is specifically designed to increase the influence of single-component loadings during the regression analysis. The weighted least squares fit also reduces the impact of calibration load schedule asymmetries on the predicted primary sensitivities of the balance gages. A weighting factor between zero and one is assigned to each calibration data point that depends on a simple count of its intentionally loaded load components or gages. The greater the number of a data point's intentionally loaded load components or gages is, the smaller its weighting factor becomes. The proposed approach is applicable to both the Iterative and Non-Iterative Methods that are used for the analysis of strain-gage balance calibration data in the aerospace testing community. The Iterative Method uses a reasonable estimate of the tare corrected load set as input for the determination of the weighting factors. The Non-Iterative Method, on the other hand, uses gage output differences relative to the natural zeros as input for the determination of the weighting factors. Machine calibration data of a six-component force balance is used to illustrate benefits of the proposed weighted least squares fit. In addition, a detailed derivation of the PRESS residuals associated with a weighted least squares fit is given in the appendices of the paper as this information could not be found in the literature. These PRESS residuals may be needed to evaluate the predictive capabilities of the final regression models that result from a weighted least squares fit of the balance calibration data.
Robertazzi, Thomas G.; Skiena, Steven; Wang, Kai
2017-08-08
Provided are an apparatus and method for load-balancing of a three-phase electric power distribution system having a multi-phase feeder, including obtaining topology information of the feeder identifying supply points for customer loads and feeder sections between the supply points, obtaining customer information that includes peak customer load at each of the points between each of the feeder sections, performing a phase balancing analysis, and recommending phase assignment at the customer load supply points.
NASA Astrophysics Data System (ADS)
Shahmir, Hamed; Nili-Ahmadabadi, Mahmoud; Naghdi, Fariba; Habibi-Parsa, Mohammad; Haririan, Ismaeil
2014-04-01
The aim of this study is to investigate the effect of thermomechanical treatment on the superelastic behavior of a Ti-50.5 at.%Ni wire in terms of loading/unloading plateau, mechanical hysteresis, and permanent set to optimize these parameters for orthodontic applications. A new three-point bending fixture, oral cavity configuration three-point bending (OCTPB) test, was utilized to determine the superelastic property in clinical condition, and therefore, the tests were carried out at 37 °C. The results indicate that the thermomechanical treatment is crucial for thermal transformation and mechanically induced transformation characteristics of the wire. Annealing of thermomechanically treated specimens at 300 and 400 °C for 1/2 and 1 h leads to good superelasticity for orthodontic applications. However, the best superelasticity at body temperature is obtained after annealing at 300 °C for 1/2 h with regard to low and constant unloading force and minimum permanent set.
Swathirajan, Chinnambedu Ravichandran; Vignesh, Ramachandran; Boobalan, Jayaseelan; Solomon, Sunil Suhas; Saravanan, Shanmugam; Balakrishnan, Pachamuthu
2017-10-01
Sustainable suppression of HIV replication forms the basis of anti-retroviral therapy (ART) medication. Thus, reliable quantification of HIV viral load has become an essential factor to monitor the effectiveness of the ART. Longer turnaround-time (TAT), batch testing and technical skills are major drawbacks of standard real-time PCR assays. The performance of the point-of-care Xpert HIV-1 viral load assay was evaluated against the Abbott RealTime PCR m2000rt system. A total of 96 plasma specimens ranging from 2.5 log10 copies ml -1 to 4.99 log10 copies ml -1 and proficiency testing panel specimens were used. Precision and accuracy were checked using the Pearson correlation co-efficient test and Bland-Altman analysis. Compared to the Abbott RealTime PCR, the Xpert HIV-1 viral load assay showed a good correlation (Pearson r=0.81; P<0.0001) with a mean difference of 0.27 log10 copies ml -1 (95 % CI, -0.41 to 0.96 log10 copies ml -1 ; sd, 0.35 log10 copies ml -1 ). Reliable and ease of testing individual specimens could make the Xpert HIV-1 viral load assay an efficient alternative method for ART monitoring in clinical management of HIV disease in resource-limited settings. The rapid test results (less than 2 h) could help in making an immediate clinical decision, which further strengthens patient care.
Experimental compliance calibration of the compact fracture toughness specimen
NASA Technical Reports Server (NTRS)
Fisher, D. M.; Buzzard, R. J.
1980-01-01
Compliances and stress intensity coefficients were determined over crack length to width ratios from 0.1 to 0.8. Displacements were measured at the load points, load line, and crack mouth. Special fixturing was devised to permit accurate measurement of load point displacement. The results are in agreement with the currently used results of boundary collocation analyses. The errors which occur in stress intensity coefficients or specimen energy input determinations made from load line displacement measurements rather than from load point measurements are emphasized.
Assessing the spatial and temporal variations of water quality in lowland areas, Northern Germany
NASA Astrophysics Data System (ADS)
Lam, Q. D.; Schmalz, B.; Fohrer, N.
2012-05-01
SummaryThe pollution of rivers and streams with agro-chemical contaminants has become one of the most crucial environmental problems in the world. The assessment of spatial and temporal variations of water quality influenced by point and diffuse source pollution is necessary to manage the environment sustainably in various watershed scales. The overall objectives of this study were to assess the transferability of parameter sets between lowland catchments on different scales using the ecohydrological model SWAT (Soil and Water Assessment Tool) and to evaluate the temporal and spatial patterns of water quality in the whole catchments before and after implementation of best management practices (BMPs). The study area Kielstau catchment is located in Northern Germany as typical example of lowland - flood plain landscape. Sandy, loamy and peat soils are characteristic for this area. Land use is dominated by arable land and pasture. In this study we examined two catchment areas including Kielstau catchment 50 km2 and its subcatchment, namely Moorau, with the area of 7.6 km2. The water quality of these catchments is not only influenced by diffuse sources from agricultural areas but also by point sources from municipal wastewater treatment plants (WWTPs). Diffuse sources as well as punctual entries from the WWTPs are considered in the model set-up. For this study, the calibration and validation of the model were carried out in a daily time step for flow and nutrients. The results indicate that the parameter sets could be transferred in lowland catchments with similar environmental conditions. Shallow groundwater is the major contributor to total nitrate load in the stream accounting for about 93% of the total nitrate load, while only about 7% originates in surface runoff and lateral flow. The study also indicates that applying a spatially distributed modeling approach was an appropriate method to generate source maps showing the spatial distribution of TN load from hydrologic response units (HRUs) as well as from subbasins and to identify the crucial pollution areas within a watershed whose management practices can be improved to control more effectively nitrogen loading to water bodies.
Heavy-Load Lifting: Acute Response in Breast Cancer Survivors at Risk for Lymphedema
BLOOMQUIST, KIRA; OTURAI, PETER; STEELE, MEGAN L.; ADAMSEN, LIS; MØLLER, TOM; CHRISTENSEN, KARL BANG; EJLERTSEN, BENT; HAYES, SANDRA C.
2018-01-01
ABSTRACT Purpose Despite a paucity of evidence, prevention guidelines typically advise avoidance of heavy lifting in an effort to protect against breast cancer–related lymphedema. This study compared acute responses in arm swelling and related symptoms after low- and heavy-load resistance exercise among women at risk for lymphedema while receiving adjuvant taxane-based chemotherapy. Methods This is a randomized, crossover equivalence trial. Women receiving adjuvant taxane-based chemotherapy for breast cancer who had undergone axillary lymph node dissection (n = 21) participated in low-load (60%–65% 1-repetition maximum, two sets of 15–20 repetitions) and heavy-load (85%–90% 1-repetition maximum, three sets of 5–8 repetitions) upper-extremity resistance exercise separated by a 1-wk wash-out period. Swelling was determined by bioimpedance spectroscopy and dual-energy x-ray absorptiometry, with breast cancer–related lymphedema symptoms (heaviness, swelling, pain, tightness) reported using a numeric rating scale (0–10). Order of low- versus heavy-load was randomized. All outcomes were assessed before, immediately after, and 24 and 72 h after exercise. Generalized estimating equations were used to evaluate changes over time between groups, with equivalence between resistance exercise loads determined using the principle of confidence interval inclusion. Results The acute response to resistance exercise was equivalent for all outcomes at all time points irrespective of loads lifted, with the exception of extracellular fluid at 72 h after exercise with less swelling after heavy loads (estimated mean difference, −1.00; 95% confidence interval, −3.17 to 1.17). Conclusions Low- and heavy-load resistance exercise elicited similar acute responses in arm swelling and breast cancer–related lymphedema symptoms in women at risk for lymphedema receiving adjuvant taxane-based chemotherapy. These represent important preliminary findings, which can be used to inform future prospective evaluation of the long-term effects of repeated exposure to heavy-load resistance exercise. PMID:28991039
Scaling Relations of Starburst-driven Galactic Winds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanner, Ryan; Cecil, Gerald; Heitsch, Fabian, E-mail: rytanner@augusta.edu
2017-07-10
Using synthetic absorption lines generated from 3D hydrodynamical simulations, we explore how the velocity of a starburst-driven galactic wind correlates with the star formation rate (SFR) and SFR density. We find strong correlations for neutral and low ionized gas, but no correlation for highly ionized gas. The correlations for neutral and low ionized gas only hold for SFRs below a critical limit set by the mass loading of the starburst, above which point the scaling relations flatten abruptly. Below this point the scaling relations depend on the temperature regime being probed by the absorption line, not on the mass loading.more » The exact scaling relation depends on whether the maximum or mean velocity of the absorption line is used. We find that the outflow velocity of neutral gas can be up to five times lower than the average velocity of ionized gas, with the velocity difference increasing for higher ionization states. Furthermore, the velocity difference depends on both the SFR and mass loading of the starburst. Thus, absorption lines of neutral or low ionized gas cannot easily be used as a proxy for the outflow velocity of the hot gas.« less
Wise, Daniel R.; Rinella, Frank A.; Rinella, Joseph F.; Fuhrer, Greg J.; Embrey, Sandra S.; Clark, Gregory M.; Schwarz, Gregory E.; Sobieszczyk, Steven
2007-01-01
This study focused on three areas that might be of interest to water-quality managers in the Pacific Northwest: (1) annual loads of total nitrogen (TN), total phosphorus (TP) and suspended sediment (SS) transported through the Columbia River and Puget Sound Basins, (2) annual yields of TN, TP, and SS relative to differences in landscape and climatic conditions between subbasin catchments (drainage basins), and (3) trends in TN, TP, and SS concentrations and loads in comparison to changes in landscape and climatic conditions in the catchments. During water year 2000, an average streamflow year in the Pacific Northwest, the Columbia River discharged about 570,000 pounds per day of TN, about 55,000 pounds per day of TP, and about 14,000 tons per day of SS to the Pacific Ocean. The Snake, Yakima, Deschutes, and Willamette Rivers contributed most of the load discharged to the Columbia River. Point-source nutrient loads to the catchments (almost exclusively from municipal wastewater treatment plants) generally were a small percentage of the total in-stream nutrient loads; however, in some reaches of the Spokane, Boise, Walla Walla, and Willamette River Basins, point sources were responsible for much of the annual in-stream nutrient load. Point-source nutrient loads generally were a small percentage of the total catchment nutrient loads compared to nonpoint sources, except for a few catchments where point-source loads comprised as much as 30 percent of the TN load and as much as 80 percent of the TP load. The annual TN and TP loads from point sources discharging directly to the Puget Sound were about equal to the annual loads from eight major tributaries. Yields of TN, TP, and SS generally were greater in catchments west of the Cascade Range. A multiple linear regression analysis showed that TN yields were significantly (p < 0.05) and positively related to precipitation, atmospheric nitrogen load, fertilizer and manure load, and point-source load, and were negatively related to average slope. TP yields were significantly related positively to precipitation, and point-source load and SS yields were significantly related positively to precipitation. Forty-eight percent of the available monitoring sites for TN had significant trends in concentration (2 increasing, 19 decreasing), 32 percent of the available sites for TP had significant trends in concentration (7 increasing, 9 decreasing), and 40 percent of the available sites for SS had significant trends in concentration (4 increasing, 15 decreasing). The trends in load followed a similar pattern, but with fewer sites showing significant trends. The results from this study indicate that inputs from nonpoint sources of nutrients probably have decreased over time in many of the catchments. Despite the generally small contribution of point-source nutrient loads, they still may have been partially responsible for the significant decreasing trends for nutrients at sites where the total point-source nutrient loads to the catchments equaled a substantial proportion of the in-stream load.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magnucka-Blandzi, Ewa
The study is devoted to stability of simply supported beam under axial compression. The beam is subjected to an axial load located at any point along the axis of the beam. The buckling problem has been desribed and solved mathematically. Critical loads have been calculated. In the particular case, the Euler’s buckling load is obtained. Explicit solutions are given. The values of critical loads are collected in tables and shown in figure. The relation between the point of the load application and the critical load is presented.
Zhang, F; de Dear, R
2017-01-01
As one of the most common strategies for managing peak electricity demand, direct load control (DLC) of air-conditioners involves cycling the compressors on and off at predetermined intervals. In university lecture theaters, the implementation of DLC induces temperature cycles which might compromise university students' learning performance. In these experiments, university students' learning performance, represented by four cognitive skills of memory, concentration, reasoning, and planning, was closely monitored under DLC-induced temperature cycles and control conditions simulated in a climate chamber. In Experiment 1 with a cooling set point temperature of 22°C, subjects' cognitive performance was relatively stable or even slightly promoted by the mild heat intensity and short heat exposure resulting from temperature cycles; in Experiment 2 with a cooling set point of 24°C, subjects' reasoning and planning performance observed a trend of decline at the higher heat intensity and longer heat exposure. Results confirm that simpler cognitive tasks are less susceptible to temperature effects than more complex tasks; the effect of thermal variations on cognitive performance follows an extended-U relationship with performance being relatively stable across a range of temperatures. DLC appears to be feasible in university lecture theaters if DLC algorithms are implemented judiciously. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Axial calibration methods of piezoelectric load sharing dynamometer
NASA Astrophysics Data System (ADS)
Zhang, Jun; Chang, Qingbing; Ren, Zongjin; Shao, Jun; Wang, Xinlei; Tian, Yu
2018-06-01
The relationship between input and output of load sharing dynamometer is seriously non-linear in different loading points of a plane, so it's significant for accutately measuring force to precisely calibrate the non-linear relationship. In this paper, firstly, based on piezoelectric load sharing dynamometer, calibration experiments of different loading points are performed in a plane. And then load sharing testing system is respectively calibrated based on BP algorithm and ELM (Extreme Learning Machine) algorithm. Finally, the results show that the calibration result of ELM is better than BP for calibrating the non-linear relationship between input and output of loading sharing dynamometer in the different loading points of a plane, which verifies that ELM algorithm is feasible in solving force non-linear measurement problem.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Croft, M.; National Synchrotron Light Source, Brookhaven National Laboratory, Upton, New York 11973; Shukla, V.
Elastic and plastic strain evolution under four-point bending has been studied by synchrotron energy dispersive x-ray diffraction. Measured strain profiles across the specimen thickness showed an increasing linear elastic strain gradient under increasing four-point bending load up to approx2 kN. The bulk elastic modulus of Ti-6Al-4V was determined as 118 GPa. The onset of plastic deformation was found to set in at a total in-plane strain of approx0.008, both under tension and compression. Plastic deformation under bending is initiated in the vicinity of the surface and at a stress of 1100 MPa, and propagates inward, while a finite core regionmore » remains elastically deformed up to 3.67 kN loading. The onset of the plastic regime and the plastic regime itself has been verified by monitoring the line broadening of the (100) peak of alpha-Ti. The effective compression/tension stress-strain curve has been obtained from the scaling collapse of strain profile data taken at seven external load levels. A similar multiple load scaling collapse of the plastic strain variation has also been obtained. The level of precision in strain measurement reported herein was evaluated and found to be 1.5x10{sup -5} or better.« less
Flexibility effects on tooth contact location in spiral bevel gear transmissions
NASA Technical Reports Server (NTRS)
Altidis, P. C.; Savage, M.
1987-01-01
An analytical method to predict the shift of the contact ellipse between the meshing teeth in a spiral bevel gear set is presented in this report. The contact ellipse shift of interest is the motion of the nominal tooth contact location on each tooth from the ideal pitch point to the point of contact between the two teeth considering the elastic motions of the gears and their supporting shafts. This is the shift of the pitch point from the ideal, unloaded position on each tooth to the nominal contact location on the tooth when the gears are fully loaded. It is assumed that the major contributors of this motion are the elastic deflections of the gear shafts, the slopes of the shafts under load and the radial deflections of the four gear shaft bearings. The motions of the two pitch point locations on the pinion and the gear tooth surfaces are calculated in a FORTRAN program which also calculates the size and orientation of the Hertzian contact ellipse on the tooth faces. Based on the curvatures of the two spiral bevel gear teeth and the size of the contact ellipse, the program also predicts the basic dynamic capacity of the tooth pair. A complete numerical example is given to illustrate the use of the program.
Experimental investigation on a high head model Francis turbine during load rejection
NASA Astrophysics Data System (ADS)
Goyal, R.; Bergan, C.; Cervantes, M. J.; Gandhi, B. K.; Dahlhaug, O. G.
2016-11-01
Francis-99 is a set of workshop aiming to determine the state of the art of high head model Francis turbine simulations (flow and structure) under steady and transient operating conditions as well as to promote their development and knowledge dissemination openly. The first workshop (Trondheim, 2014) was concerned with steady state operation. The second workshop will focus on transient operations such as load variation and start-stop. In the present work, 2-D particle image velocimetry (PIV) with synchronized pressure measurements performed in the draft tube cone of the Francis-99 test case during load rejection is presented. Pressure sensors were mounted in the vaneless space and draft tube cone to estimate the instantaneous pressure fluctuations while operating the turbine from the best efficiency point (9.8°) to part load (6.7°) with the presence of a rotating vortex rope (RVR). The time-resolved velocity and pressure data are presented in this paper showing the transition in the turbine from one state to another.
Optimal PID gain schedule for hydrogenerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orelind, G.; Wozniak, L.; Medanic, J.
1989-09-01
This paper describes the development and testing of a digital gain switching governor for hydrogenerators. Optimal gains were found at different load points by minimizing a quadratic performance criterion prior to controller operating. During operation, the gain sets are switched in depending on the gate position and speed error magnitude. With gain switching operating, the digital governor was shown to have a substantial reduction of noise on the command signal and up to 42% faster responses to power requests. Non-linear control strategies enabled the digital governor to have a 2.5% to 2% reduction in speed overshoot on startups, and anmore » 8% to 1% reduction in undershoot on load rejections as compared to the analog.« less
Short-term Recovery Following Resistance Exercise Leading or not to Failure.
González-Badillo, J J; Rodríguez-Rosell, D; Sánchez-Medina, L; Ribas, J; López-López, C; Mora-Custodio, R; Yañez-García, J M; Pareja-Blanco, F
2016-04-01
This study analyzed the time course of recovery following 2 resistance exercise protocols differing in level of effort: maximum (to failure) vs. half-maximum number of repetitions per set. 9 males performed 3 sets of 4 vs. 8 repetitions with their 80% 1RM load, 3×4(8) vs. 3×8(8), in the bench press and squat. Several time-points from 24 h pre- to 48 h post-exercise were established to assess the mechanical (countermovement jump height, CMJ; velocity against the 1 m·s(-1) load, V1-load), biochemical (testosterone, cortisol, GH, prolactin, IGF-1, CK) and heart rate variability (HRV) and complexity (HRC) response to exercise. 3×8(8) resulted in greater neuromuscular fatigue (higher reductions in repetition velocity and velocity against V1-load) than 3×4(8). CMJ remained reduced up to 48 h post-exercise following 3×8(8), whereas it was recovered after 6 h for 3×4(8). Significantly greater prolactin and IGF-1 levels were found for 3×8(8) vs. 3×4(8). Significant reductions in HRV and HRC were observed for 3×8(8) vs. 3×4(8) in the immediate recovery. Performing a half-maximum number of repetitions per set resulted in: 1) a stimulus of faster mean repetition velocities; 2) lower impairment of neuromuscular performance and faster recovery; 3) reduced hormonal response and muscle damage; and 4) lower reduction in HRV and HRC following exercise. © Georg Thieme Verlag KG Stuttgart · New York.
Optimal Control Allocation with Load Sensor Feedback for Active Load Suppression
NASA Technical Reports Server (NTRS)
Miller, Christopher
2017-01-01
These slide sets describe the OCLA formulation and associated algorithms as a set of new technologies in the first practical application of load limiting flight control utilizing load feedback as a primary control measurement. Slide set one describes Experiment Development and slide set two describes Flight-Test Performance.
McBride, Jeffrey M; Porcari, John P; Scheunke, Mark D
2004-11-01
This investigation was designed to determine if vibration during fatiguing resistance exercise would alter associated patterns of muscle activity. A cross-over design was employed with 8 subjects completing a resistance exercise bout once with a vibrating dumbbell (V) (44 Hz, 3 mm displacement) and once without vibration (NV). For both exercise bouts, 10 sets were performed with a load that induced concentric muscle failure during the 10th repetition. The appropriate load for each set was determined during a pretest. Each testing session was separated by 1 week. Electromyography (EMG) was obtained from the biceps brachii muscle at 12 different time points during a maximum voluntary contraction (MVC) at a 170 degrees elbow angle after each set of the dumbbell exercise. The time points were as follows: pre (5 minutes before the resistance exercise bout), T1-T10 (immediately following each set of resistance exercise), and post (15 minutes after the resistance exercise bout). EMG was analyzed for median power frequency (MPF) and maximum (mEMG). NV resulted in a significant decrease in MPF at T1-T4 (p < or 0.05) and a significant increase in mEMG at T2 during the MVC. V had an overall trend of lower mEMG in comparison to NV. The mEMG and MPF values associated with NV were similar to previously reported investigations. The lower mEMG values and the higher MPF of V in comparison to NV are undocumented. The EMG patterns observed with vibration may indicate a more efficient and effective recruitment of high threshold motor units during fatiguing contractions. This may indicate the usage of vibration with resistance exercise as an effective tool for strength training athletes.
Driver for solar cell I-V characteristic plots
NASA Technical Reports Server (NTRS)
Turner, G. B. (Inventor)
1980-01-01
A bipolar voltage ramp generator which applies a linear voltage through a resistor to a solar cell for plotting its current versus voltage (I-V) characteristic between short circuit and open circuit conditions is disclosed. The generator has automatic stops at the end points. The resistor serves the multiple purpose of providing a current sensing resistor, setting the full-scale current value, and providing a load line with a slope approximately equal to one, such that it will pass through the origin and the approximate center of the I-V curve with about equal distance from that center to each of the end points.
NASA Technical Reports Server (NTRS)
Binienda, Wieslaw K.; Roberts, Gary D.; Papadopoulos, Demetrios S.
1992-01-01
The results of in-plane four-point bend experiments on unidirectionally reinforced composite beams are presented for graphite/epoxy (T300/934) and graphite/polyimide (G30-500/PMR-15) composites. The maximum load and the location of cracks formed during failure were measured for testpieces with fibers oriented at various angles to the beam axis. Since most of the beams failed near one or more of the load points, the strength of the beams was evaluated in terms of a proposed model, for the local stress distribution. In this model, an exact solution to the problem of a localized contact force acting on a unidirectionally reinforced half plane is used to describe the local stress field. The stress singularity at the load points is treated in a manner similar to the stress singularity at a crack tip in fracture mechanisms problems. Using this approach, the effect of fiber angle and elastic material properties on the strength of the beam is described in terms of a load intensity factor. For fiber angles less than 45 deg from the beam axis, a single crack is initiated near one of the load points at a critical value of the load intensity factor. The critical load intensity factor decreases with the increasing fiber angle. For larger fiber angles, multiple cracks occur at locations both near and away from the load points, and the load intensity factor at failure increases sharply with increasing fiber angle.
NASA Technical Reports Server (NTRS)
Binienda, W. K.; Roberts, G. D.; Papadopoulos, D. S.
1992-01-01
The results of in-plane four-point bend experiments on unidirectionally reinforced composite beams are presented for graphite/epoxy (T300/934) and graphite/polyimide (G30-500/PMR-15) composites. The maximum load and the location of cracks formed during failure were measured for testpieces with fibers oriented at various angles to the beam axis. Since most of the beams failed near one or more of the load points, the strength of the beams was evaluated in terms of a proposed model for the local stress distribution. In this model, an exact solution to the problem of a localized contact force acting on a unidirectionally reinforced half plane is used to describe the local stress field. The stress singularity at the load points is treated in a manner similar to the stress singularity at a crack tip in fracture mechanisms problems. Using this approach, the effect of fiber angle and elastic material properties on the strength of the beam is described in terms of a load intensity factor. For fiber angles less than 45 deg from the beam axis, a single crack is initiated near one of the load points at a critical value of the load intensity factor. The critical load intensity factor decreases with increasing fiber angle. For larger fiber angles, multiple cracks occur at locations both near and away from the load points, and the load intensity factor at failure increases sharply with increasing fiber angle.
Maupin, Molly A.; Ivahnenko, Tamara
2011-01-01
Data from the United States Environmental Protection Agency Permit Compliance System national database were used to calculate annual total nitrogen (TN) and total phosphorus (TP) loads to surface waters from municipal and industrial facilities in six major regions of the United States for 1992, 1997, and 2002. Concentration and effluent flow data were examined for approximately 118,250 facilities in 45 states and the District of Columbia. Inconsistent and incomplete discharge locations, effluent flows, and effluent nutrient concentrations limited the use of these data for calculating nutrient loads. More concentrations were reported for major facilities, those discharging more than 1 million gallons per day, than for minor facilities, and more concentrations were reported for TP than for TN. Analytical methods to check and improve the quality of the Permit Compliance System data were used. Annual loads were calculated using "typical pollutant concentrations" to supplement missing concentrations based on the type and size of facilities. Annual nutrient loads for over 26,600 facilities were calculated for at least one of the three years. Sewage systems represented 74% of all TN loads and 58% of all TP loads. This work represents an initial set of data to develop a comprehensive and consistent national database of point-source nutrient loads. These loads can be used to inform a wide range of water-quality management, watershed modeling, and research efforts at multiple scales.
NASA Astrophysics Data System (ADS)
Fang, Huaiyang; Lu, Qingshui; Gao, Zhiqiang; Shi, Runhe; Gao, Wei
2013-09-01
China economy has been rapidly increased since 1978. Rapid economic growth led to fast growth of fertilizer and pesticide consumption. A significant portion of fertilizers and pesticides entered the water and caused water quality degradation. At the same time, rapid economic growth also caused more and more point source pollution discharge into the water. Eutrophication has become a major threat to the water bodies. Worsening environment problems forced governments to take measures to control water pollution. We extracted land cover from Landsat TM images; calculated point source pollution with export coefficient method; then SWAT model was run to simulate non-point source pollution. We found that the annual TP loads from industry pollution into rivers are 115.0 t in the entire watershed. Average annual TP loads from each sub-basin ranged from 0 to 189.4 ton. Higher TP loads of each basin from livestock and human living mainly occurs in the areas where they are far from large towns or cities and the TP loads from industry are relatively low. Mean annual TP loads that delivered to the streams was 246.4 tons and the highest TP loads occurred in north part of this area, and the lowest TP loads is mainly distributed in middle part. Therefore, point source pollution has much high proportion in this area and governments should take measures to control point source pollution.
An approach for the regularization of a power flow solution around the maximum loading point
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kataoka, Y.
1992-08-01
In the conventional power flow solution, the boundary conditions are directly specified by active power and reactive power at each node, so that the singular point coincided with the maximum loading point. For this reason, the computations are often disturbed by ill-condition. This paper proposes a new method for getting the wide-range regularity by giving some modifications to the conventional power flow solution method, thereby eliminating the singular point or shifting it to the region with the voltage lower than that of the maximum loading point. Then, the continuous execution of V-P curves including maximum loading point is realized. Themore » efficiency and effectiveness of the method are tested in practical 598-nodes system in comparison with the conventional method.« less
Developement of watershed and reference loads for a TMDL in Charleston Harbor System, SC.
Silong Lu; Devenra Amatya; Jamie Miller
2005-01-01
It is essential to determine point and non-point source loads and their distribution for development of a dissolved oxygen (DO) Total Maximum Daily Load (TMDL). A series of models were developed to assess sources of oxygen-demand loadings in Charleston Harbor, South Carolina. These oxygen-demand loadings included nutrients and BOD. Stream flow and nutrient...
Maintenance of equilibrium point control during an unexpectedly loaded rapid limb movement.
Simmons, R W; Richardson, C
1984-06-08
Two experiments investigated whether the equilibrium point hypothesis or the mass-spring model of motor control subserves positioning accuracy during spring loaded, rapid, bi-articulated movement. For intact preparations, the equilibrium point hypothesis predicts response accuracy to be determined by a mixture of afferent and efferent information, whereas the mass-spring model predicts positioning to be under a direct control system. Subjects completed a series of load-resisted training trials to a spatial target. The magnitude of a sustained spring load was unexpectedly increased on selected trials. Results indicated positioning accuracy and applied force varied with increases in load, which suggests that the original efferent commands are modified by afferent information during the movement as predicted by the equilibrium point hypothesis.
Installation Torque Tables for Noncritical Applications
NASA Technical Reports Server (NTRS)
Rivera-Rosario, Hazel T.; Powell, Joseph S.
2017-01-01
The objective of this project is to define torque values for bolts and screws when loading is not a concern. Fasteners require a certain torque to fulfill its function and prevent failure. NASA Glenn Research Center did not have a set of fastener torque tables for non-critical applications without loads, usually referring to hand-tight or wrench-tight torqueing. The project is based on two formulas, torque and pullout load. Torque values are calculated giving way to preliminary data tables. Testing is done to various bolts and metal plates, torqueing them until the point of failure. Around 640 torque tables were developed for UNC, UNF, and M fasteners. Different lengths of thread engagement were analyzed for the 5 most common materials used at GRC. The tables were put together in an Excel spreadsheet and then formatted into a Word document. The plan is to later convert this to an official technical publication or memorandum.
Bench press exercise: the key points.
Padulo, J; Laffaye, G; Chaouachi, A; Chamari, K
2015-06-01
The bench press exercise (BPE) is receiving increasing interest as a field testing, training/therapeutic modality to improve neuromuscular performance or to increase bone mass density. Several studies have been performed using BPE as a standard for increasing upper-limb strength. For this purpose, the position of the bar, the loads, the sets, the number of repetitions, the recovery time in-between sets, the movement speed, the muscular work and the use of the determination of the one repetition maximum (1-RM) are the classical tools investigated in the literature that have been shown to affect the BPE effect on neuromuscular. The goal of the present short review is to make a picture of the current knowledge on the bench press exercise, which could be very helpful for a better understanding of this standard movement and its effects. Based on the related literature, several recommendations on these key points are presented here.
Computer Programs for Settlement Analysis.
1980-10-01
sieer ,d if - ... ly and identity by &ock .. mbr ) C(ohesiv’ soils Load tests (Foundations) Computer programs Set t l ement Embanikments Settlement...and stress conditions that are altered by a changing water table and settlement-dependent submergence of the soil. 9. FD31 is a specialized program...are saturated and have submerged unit weights of 50 lb/ft 3 The clay is linearly elastic and the consolidation curve passes through 2 2 the points (e, a
The Effect of the Number of Sets on Power Output for Different Loads
Morales-Artacho, Antonio J.; Padial, Paulino; García-Ramos, Amador; Feriche, Belén
2015-01-01
There is much debate concerning the optimal load (OL) for power training. The purpose of this study was to investigate the effect of the number of sets performed for a given load on mean power output (Pmean). Fourteen physically active men performed 3 sets of 3 bench-press repetitions with 30, 40 and 50 kg. The highest mean power value (Pmax) across all loads and Pmean were compared when data were taken from the first set at each absolute load vs. from the best of three sets performed. Pmean increased from the first to the third set (from 5.99 ± 0.81 to 6.16 ± 0.96 W·kg−1, p = 0.017), resulting in a main effect of the set number (p < 0.05). At the 30 kg load Pmean increased from the first to the third set (from 6.01 ± 0.75 to 6.35 ± 0.85 W·kg−1; p < 0.01). No significant effect was observed at 40 and 50 kg loads (p > 0.05). Pmax and velocity were significantly affected by the method employed to determine Pmean at each load (p < 0.05). These results show a positive effect of the number of sets per load on Pmean, affecting Pmax, OL and potentially power training prescription. PMID:26240658
Karlsson, Ingrid; Malleret, Benoît; Brochard, Patricia; Delache, Benoît; Calvo, Julien; Le Grand, Roger; Vaslin, Bruno
2007-01-01
The early immune response fails to prevent the establishment of chronic human immunodeficiency virus (HIV) infection but may influence viremia during primary infection, thereby possibly affecting long-term disease progression. CD25+ FoxP3+ regulatory T cells may contribute to HIV/simian immunodeficiency virus (SIV) pathogenesis by suppressing efficient antiviral responses during primary infection, favoring high levels of viral replication and the establishment of chronic infection. In contrast, they may decrease immune activation during chronic infection. CD4+ regulatory T cells have been studied in the most detail, but CD8+ CD25+ FoxP3+ T cells also have regulatory properties. We monitored the dynamics of CD25+ FoxP3+ T cells during primary and chronic SIVmac251 infection in cynomolgus macaques. The number of peripheral CD4+ CD25+ FoxP3+ T cells paralleled that of memory CD4+ T cells, with a rapid decline during primary infection followed by a rebound to levels just below baseline and gradual depletion during the course of infection. No change in the proportion of CD25+ FoxP3+ T cells was observed in peripheral lymph nodes. A small number of CD4+ CD25+ FoxP3+ T cells at set point was associated with a high plasma viral load. In contrast, peripheral CD8+ CD25+ FoxP3+ T cells were induced a few days after peak plasma viral load during primary infection. The number of these cells was positively correlated with viral load and negatively correlated with CD4+ T-cell activation, SIV antigen-specific proliferative responses during primary infection, and plasma viral load at set point, with large numbers of CD8+ CD25+ FoxP3+ T cells being indicative of a poor prognosis. PMID:17898053
Vertical load capacities of roof truss cross members.
Gearhart, David F; Morsy, Mohamed Khaled
2016-05-01
Trusses used for roof support in coal mines are constructed of two grouted bolts installed at opposing forty-five degree angles into the roof and a cross member that ties the angled bolts together. The load on the cross member is vertical, which is transverse to the longitudinal axis, and therefore the cross member is loaded in the weakest direction. Laboratory tests were conducted to determine the vertical load capacity and deflection of three different types of cross members. Single-point load tests, with the load applied in the center of the specimen and double-point load tests, with a span of 2.4 m, were conducted. For the single-point load configuration, the yield of the 25 mm solid bar cross member was nominally 98 kN of vertical load, achieved at 42 cm of deflection. For cable cross members, yield was not achieved even after 45 cm of deflection. Peak vertical loads were about 89 kN for 17 mm cables and 67 kN for the 15 mm cables. For the double-point load configurations, the 25 mm solid bar cross members yielded at 150 kN of vertical load and 25 cm of deflection. At 25 cm of deflection individual cable strands started breaking at 133 and 111 kN of vertical load for the 17 and 15 mm cable cross members respectively.
A method to approximate a closest loadability limit using multiple load flow solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yorino, Naoto; Harada, Shigemi; Cheng, Haozhong
A new method is proposed to approximate a closest loadability limit (CLL), or closest saddle node bifurcation point, using a pair of multiple load flow solutions. More strictly, the obtainable points by the method are the stationary points including not only CLL but also farthest and saddle points. An operating solution and a low voltage load flow solution are used to efficiently estimate the node injections at a CLL as well as the left and right eigenvectors corresponding to the zero eigenvalue of the load flow Jacobian. They can be used in monitoring loadability margin, in identification of weak spotsmore » in a power system and in the examination of an optimal control against voltage collapse. Most of the computation time of the proposed method is taken in calculating the load flow solution pair. The remaining computation time is less than that of an ordinary load flow.« less
Tracy, J.C.; Bernknopf, R.; Forney, W.; Hill, K.
2004-01-01
The Federal Clean Water Act (Section 303(d)) mandates that states develop Total Maximum Daily Load (TMDL) plans for water bodies that are on the Section 303(d) list. To be placed on the 303(d) list, a water body must be found to have water quality conditions that limit its ability to meet its designated beneficial uses. The TMDL for a water body is defined in 40 CFR 130 as the sum of waste load allocations from identified points sources and non-point sources within the water body's watershed. The TMDL plan for a listed water body should identify the current waste loads to the water body, the waste load capacity of the water body and then allocate the waste load capacity to the known point and non-point sources of pollution within the water body's watershed. Copyright 2004 ASCE.
Wireless power charging using point of load controlled high frequency power converters
Miller, John M.; Campbell, Steven L.; Chambon, Paul H.; Seiber, Larry E.; White, Clifford P.
2015-10-13
An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.
NASA Astrophysics Data System (ADS)
Zheng, Sifa; Liu, Haitao; Dan, Jiabi; Lian, Xiaomin
2015-05-01
Linear time-invariant assumption for the determination of acoustic source characteristics, the source strength and the source impedance in the frequency domain has been proved reasonable in the design of an exhaust system. Different methods have been proposed to its identification and the multi-load method is widely used for its convenience by varying the load number and impedance. Theoretical error analysis has rarely been referred to and previous results have shown an overdetermined set of open pipes can reduce the identification error. This paper contributes a theoretical error analysis for the load selection. The relationships between the error in the identification of source characteristics and the load selection were analysed. A general linear time-invariant model was built based on the four-load method. To analyse the error of the source impedance, an error estimation function was proposed. The dispersion of the source pressure was obtained by an inverse calculation as an indicator to detect the accuracy of the results. It was found that for a certain load length, the load resistance at the frequency points of one-quarter wavelength of odd multiples results in peaks and in the maximum error for source impedance identification. Therefore, the load impedance of frequency range within the one-quarter wavelength of odd multiples should not be used for source impedance identification. If the selected loads have more similar resistance values (i.e., the same order of magnitude), the identification error of the source impedance could be effectively reduced.
Optimization of K-shell emission in aluminum z-pinch implosions: Theory versus experiment
NASA Astrophysics Data System (ADS)
Whitney, K. G.; Thornhill, J. W.; Giuliani, J. L.; Davis, J.; Miles, L. A.; Nolting, E. E.; Kenyon, V. L.; Speicer, W. A.; Draper, J. A.; Parsons, C. R.; Dang, P.; Spielman, R. B.; Nash, T. J.; McGurn, J. S.; Ruggles, L. E.; Deeney, C.; Prasad, R. R.; Warren, L.
1994-09-01
Two sets of z-pinch experiments were recently completed at the Saturn and Phoenix facilities of Sandia National Laboratories and the Naval Surface Warfare Center, respectively, using aluminum wire arrays of different wire and array diameters. Measurements of the total x-ray yield from the K shell of aluminum were made. In this paper, a comparison of these measurements is made to both theoretical predictions and to a similar set of earlier measurements that were made at the Double Eagle facility of Physics International Company. These three sets of yield measurements have points of agreement with predicted yields and with each other, but they also show points of mutual disagreement, whose significance is discussed. The data are analyzed using a slightly revised version of a previously published K-shell yield scaling law, and they support the existence of a reasonably well defined region in (load mass)-(implosion velocity) space in which plasma kinetic energy is efficiently converted into K-shell x rays. Furthermore, a correlation is observed between the inferred conversion efficiencies and the times in which the implosions occur relative to the times when each generator's short-circuit current reaches its peak value. Finally, unlike the Double Eagle experiments, the largest measured yields in the new experiments were observed to occur at the upper velocity boundary of the efficient emission region. Moreover, the observed yields are in fairly good quantitative agreement with an earlier scaling law prediction of the maximum K-shell x-ray yield from aluminum as a function of load mass assuming kinetic energy conversion alone.
Performance testing of 3D point cloud software
NASA Astrophysics Data System (ADS)
Varela-González, M.; González-Jorge, H.; Riveiro, B.; Arias, P.
2013-10-01
LiDAR systems are being used widely in recent years for many applications in the engineering field: civil engineering, cultural heritage, mining, industry and environmental engineering. One of the most important limitations of this technology is the large computational requirements involved in data processing, especially for large mobile LiDAR datasets. Several software solutions for data managing are available in the market, including open source suites, however, users often unknown methodologies to verify their performance properly. In this work a methodology for LiDAR software performance testing is presented and four different suites are studied: QT Modeler, VR Mesh, AutoCAD 3D Civil and the Point Cloud Library running in software developed at the University of Vigo (SITEGI). The software based on the Point Cloud Library shows better results in the loading time of the point clouds and CPU usage. However, it is not as strong as commercial suites in working set and commit size tests.
Modeling CO{sub 2} and H{sub 2}S solubility in MDEA and DEA: Design implications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rochelle, G.T.; Posey, M.
1996-12-31
The solubility of H{sub 2}S and CO{sub 2} in aqueous alkanolamines affects solution capacity and the required circulation rate for acid gas absorption. These thermodynamics also determine the relationship of steam rate and the lean loading of the solution which in turn sets the leak of acid gas from the top of the absorber. Finally, the mechanisms of mass transfer and the role of kinetics, especially in stripping, depend on the vapor/liquid equilibria. Published measurements of CO{sub 2} and H{sub 2}S solubility in methyldiethanolamine (MDEA) and diethanolamine (DEA) are not in general agreement, especially at low loading of acid gas.more » The available sets of solubility data have been regressed with the AspenPlus electrolyte/NRTL model. All of the parameters and constants that make up this model have been carefully evaluated. Independent thermodynamic data such as freezing point and heat of mixing have been included in the regression to strengthen the estimates of model parameters. The parameters for each set of solubility data have been evaluated in an attempt to determine which set is correct. Each evaluated model has been used to calculate the acid gas capacity and minimum stripping steam rate for several industrial cases of acid gas absorption/stripping.« less
Quantifying morphological changes of cape-related shoals
NASA Astrophysics Data System (ADS)
Paniagua-Arroyave, J. F.; Adams, P. N.; Parra, S. M.; Valle-Levinson, A.
2017-12-01
The rising demand for marine resources has motivated the study of inner shelf transport processes, especially in locations with highly-developed coastlines, endangered-species habitats, and valuable economic resources. These characteristics are found at Cape Canaveral shoals, on the Florida Atlantic coast, where transport dynamics and morphological evolution are not well understood. To study morphological changes at these shoals, two sets of paired upward- and downward-pointing acoustic Doppler current profilers (ADCPs) were deployed in winter 2015-2016. One set was deployed at the inner swale of Shoal E, 20 km southeast of the cape tip in 13 m depth, while the other set was located at the edge of Southeast shoal in 5 m deep. Upward-pointing velocity profiles and suspended particle concentrations were implemented in the Exner equation to quantify instantaneous rates of change in bed elevation. This computation includes changes in sediment concentration and the advection of suspended particles, but does not account for spatial gradients in bed-load fluxes and water velocities. The results of the computation were then compared to bed change rates measured directly by the downward-pointing ADCPs. At the easternmost ridge, quantified bed elevation change rates ranged from -7×10-7 to 4×10-7 m/s, and those at the inner swale ranged from -4×10-7 to 8×10-7 m/s. These values were two orders of magnitude smaller than rates measured by downward-pointing ADCPs. Moreover, the cumulative changes were two orders of magnitude larger at the ridge (-0.33 m, downward, and -0.13, m upward) than at the inner swale (cf. -6×10-3 m, downward, and 3×10-3 m, upward). These values suggest that bedform migration may be occurring at the ridge, that suspended sediments account for up to 30% of total bed changes, and that gradients in bed-load fluxes exert control on morphological change over the shoals. Despite uncertainties related to the ADCP-derived sediment concentrations, these findings provide preliminary evidence about the spatial variability in morphological changes over cape-related shoals.
A data-driven approach of load monitoring on laminated composite plates using support vector machine
NASA Astrophysics Data System (ADS)
Gwon, Y. S.; Fekrmandi, H.
2018-03-01
In this study, the surface response to excitation method (SuRE) is investigated using a data-driven method for load monitoring on a laminated composite plate structure. The SuRE method is an emerging approach in ultrasonic wavebased structural health monitoring (SHM) field. In this method, a range of high-frequency, surface-guided waves are excited on the structure using piezoceramic elements. The waves propagate on the structure and interact with internal or surface damages. Initially, a baseline data of the intact structure is created by measuring the frequency transfer function between the excitation and sensing point. The integrity of structure is evaluated by monitoring changes in the frequency spectrums. The SuRE method has effectively been used for a variety of SHM applications including the detection of loose bolts, delamination in composite structures, internal corrosion in pipelines, and load and impact monitoring. Data obtained using the SuRE method was used for identifying the location of the applied load on a laminated composite plate using Support Vector Machine (SVM). A set of two piezoelectric elements were attached on the surface of the plate. A sweep excitation (150-250 kHz) generated surface-guided waves, and the transmitted waves were monitored at the sensory positions. The reference data set was measured simultaneously from the sensors. The plate was subjected to static loads while health monitoring data was being captured using the SuRE method. The confusion matrix indicated that the model classified correctly with up to 99.8% accuracy.
Simultaneous measurement of passage through the restriction point and MCM loading in single cells
Håland, T. W.; Boye, E.; Stokke, T.; Grallert, B.; Syljuåsen, R. G.
2015-01-01
Passage through the Retinoblastoma protein (RB1)-dependent restriction point and the loading of minichromosome maintenance proteins (MCMs) are two crucial events in G1-phase that help maintain genome integrity. Deregulation of these processes can cause uncontrolled proliferation and cancer development. Both events have been extensively characterized individually, but their relative timing and inter-dependence remain less clear. Here, we describe a novel method to simultaneously measure MCM loading and passage through the restriction point. We exploit that the RB1 protein is anchored in G1-phase but is released when hyper-phosphorylated at the restriction point. After extracting cells with salt and detergent before fixation we can simultaneously measure, by flow cytometry, the loading of MCMs onto chromatin and RB1 binding to determine the order of the two events in individual cells. We have used this method to examine the relative timing of the two events in human cells. Whereas in BJ fibroblasts released from G0-phase MCM loading started mainly after the restriction point, in a significant fraction of exponentially growing BJ and U2OS osteosarcoma cells MCMs were loaded in G1-phase with RB1 anchored, demonstrating that MCM loading can also start before the restriction point. These results were supported by measurements in synchronized U2OS cells. PMID:26250117
Biodynamic Assessment of Pilot Knee-Board Configurations During Simulated T-38 Catapult Acceleration
2015-04-01
Apple iPad Mini with a shock case. The T-38C ejection pulse was simulated using the Vertical Deceleration Tower (VDT) set-up with a Martin Baker Mk...Figure 6. Free-body Diagram to Illustrate Loading and Bending Moment at Mid-Point of Femur (Schematic from Kennedy, VPI Thesis , 2004...kneeboard configuration compared to the paper kneeboard configuration. The proposed kneeboard configuration consisted of an Apple iPad Mini with a
CO2 concentration and occupancy density in the critical zones served by the VAV system
NASA Astrophysics Data System (ADS)
Etoua Evina, Ghislaine; Kajl, Stanislaw; Lamarche, Louis; Beltran-Galindo, Javier
2017-11-01
This article presents the results obtained from monitoring a VAV system with highly diversified zone occupancy density are presented in the article. The investigated VAV system meets the load for 72 zones (68 perimeters and 4 interiors) consisting of classrooms, offices, conference rooms, etc. with highly diversified occupancy densities from 1.875 to 2.5 m2/person for the classrooms and from 10 to 15 m2/person for the offices. The monitoring shows that the CO2 concentration can exceed the set point in the critical rooms. Simulation results are also presented in the article to show that it is often impossible to adjust the operation of such VAV systems because the adjusted System Outdoor Air Fractions, % OA, can reach 100% even where the zone CO2 concentration is not respected. The presented monitoring and simulation results were obtained in the winter, with the VAV system operating at partial load and with the minimum outdoor air flowrate required by the economizer system. As shown in the article, to respect the zone set point CO2 concentration in such period, the VAV system must operate mostly at a %OA equal to 100% instead of its minimum value. To circumvent this, the supply zone air flow rate may have to be designed taking into account the CO2 concentration resulting from the critical zones occupancy density.
Klatt, Nichole R; Villinger, Francois; Bostik, Pavel; Gordon, Shari N; Pereira, Lara; Engram, Jessica C; Mayne, Ann; Dunham, Richard M; Lawson, Benton; Ratcliffe, Sarah J; Sodora, Donald L; Else, James; Reimann, Keith; Staprans, Silvija I; Haase, Ashley T; Estes, Jacob D; Silvestri, Guido; Ansari, Aftab A
2008-06-01
Naturally SIV-infected sooty mangabeys (SMs) remain asymptomatic despite high virus replication. Elucidating the mechanisms underlying AIDS resistance of SIV-infected SMs may provide crucial information to better understand AIDS pathogenesis. In this study, we assessed the determinants of set-point viremia in naturally SIV-infected SMs, i.e., immune control of SIV replication versus target cell limitation. We depleted CD4+ T cells in 6 naturally SIV-infected SMs by treating with humanized anti-CD4 mAb (Cdr-OKT4A-huIgG1). CD4+ T cells were depleted almost completely in blood and BM and at variable levels in mucosal tissues and LNs. No marked depletion of CD14+ monocytes was observed. Importantly, CD4+ T cell depletion was associated with a rapid, significant decline in viral load, which returned to baseline level at day 30-45, coincident with an increased fraction of proliferating and activated CD4+ T cells. Throughout the study, virus replication correlated with the level of proliferating CD4+ T cells. CD4+ T cell depletion did not induce any changes in the fraction of Tregs or the level of SIV-specific CD8+ T cells. Our results suggest that the availability of activated CD4+ T cells, rather than immune control of SIV replication, is the main determinant of set-point viral load during natural SIV infection of SMs.
Amand, L; Carlsson, B
2013-01-01
Ammonium feedback control is increasingly used to determine the dissolved oxygen (DO) set-point in aerated activated sludge processes for nitrogen removal. This study compares proportional-integral (PI) ammonium feedback control with a DO profile created from a mathematical minimisation of the daily air flow rate. All simulated scenarios are set to reach the same treatment level of ammonium, based on a daily average concentration. The influent includes daily variations only and the model has three aerated zones. Comparisons are made at different plant loads and DO concentrations, and the placement of the ammonium sensor is investigated. The results show that ammonium PI control can achieve the best performance if the DO set-point is limited at a maximum value and with little integral action in the controller. Compared with constant DO control the best-performing ammonium controller can achieve 1-3.5% savings in the air flow rate, while the optimal solution can achieve a 3-7% saving. Energy savings are larger when operating at higher DO concentrations.
Optimization of Nanowire-Resistance Load Logic Inverter.
Hashim, Yasir; Sidek, Othman
2015-09-01
This study is the first to demonstrate characteristics optimization of nanowire resistance load inverter. Noise margins and inflection voltage of transfer characteristics are used as limiting factors in this optimization. Results indicate that optimization depends on resistance value. Increasing of load resistor tends to increasing in noise margins until saturation point, increasing load resistor after this point will not improve noise margins significantly.
2016-01-01
It is important to consider the role of diagnostics and the critical need for quality diagnostics services in resource-limited settings. Accurate diagnostic tests play a key role in patient management and the prevention and control of most infectious diseases. As countries plan for implementation of HIV early infant diagnosis and viral load point-of-care testing, the London School of Hygiene & Tropical Medicine has worked with countries and partners with an interest in external quality assurance to support quality point-of-care testing on the continent. Through a series of collaborative consultations and workshops, the London School of Hygiene & Tropical Medicine has gathered lessons learned, tools, and resources and developed quality assurance models that will support point-of-care testing. The London School of Hygiene & Tropical Medicine is committed to the continued advancement of laboratory diagnostics in Africa and quality laboratory services and point-of-care testing. PMID:28879132
Gonneaud, Julie; Kalpouzos, Grégoria; Bon, Laetitia; Viader, Fausto; Eustache, Francis; Desgranges, Béatrice
2011-01-01
Prospective memory (PM) is the ability to remember to perform an action at a specific point in the future. Regarded as multidimensional, PM involves several cognitive functions that are known to be impaired in normal aging. In the present study, we set out to investigate the cognitive correlates of PM impairment in normal aging. Manipulating cognitive load, we assessed event- and time-based PM, as well as several cognitive functions, including executive functions, working memory and retrospective episodic memory, in healthy subjects covering the entire adulthood. We found that normal aging was characterized by PM decline in all conditions and that event-based PM was more sensitive to the effects of aging than time-based PM. Whatever the conditions, PM was linked to inhibition and processing speed. However, while event-based PM was mainly mediated by binding and retrospective memory processes, time-based PM was mainly related to inhibition. The only distinction between high- and low-load PM cognitive correlates lays in an additional, but marginal, correlation between updating and the high-load PM condition. The association of distinct cognitive functions, as well as shared mechanisms with event- and time-based PM confirms that each type of PM relies on a different set of processes. PMID:21678154
Spinning Reserve From Hotel Load Response: Initial Progress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kueck, John D; Kirby, Brendan J
2008-11-01
This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby andmore » Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.« less
Variations in medial-lateral hamstring force and force ratio influence tibiofemoral kinematics.
Shalhoub, Sami; Fitzwater, Fallon G; Cyr, Adam J; Maletsky, Lorin P
2016-10-01
A change in hamstring strength and activation is typically seen after injuries or invasive surgeries such as anterior cruciate reconstruction or total knee replacement. While many studies have investigated the influence of isometric increases in hamstring load on knee joint kinematics, few have quantified the change in kinematics due to a variation in medial to lateral hamstring force ratio. This study examined the changes in knee joint kinematics on eight cadaveric knees during an open-chain deep knee bend for six different loading configurations: five loaded hamstring configurations that varied the ratio of a total load of 175 N between the semimembranosus and biceps femoris and one with no loads on the hamstring. The anterior-posterior translation of the medial and lateral femoral condyles' lowest points along proximal-distal axis of the tibia, the axial rotation of the tibia, and the quadriceps load were measured at each flexion angle. Unloading the hamstring shifted the medial and lateral lowest points posteriorly and increased tibial internal rotation. The influence of unloading hamstrings on quadriceps load was small in early flexion and increased with knee flexion. The loading configuration with the highest lateral hamstrings force resulted in the most posterior translation of the medial lowest point, most anterior translation of the lateral lowest point, and the highest tibial external rotation of the five loading configurations. As the medial hamstring force ratio increased, the medial lowest point shifted anteriorly, the lateral lowest point shifted posteriorly, and the tibia rotated more internally. The results of this study, demonstrate that variation in medial-lateral hamstrings force and force ratio influence tibiofemoral transverse kinematics and quadriceps loads required to extend the knee. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1707-1715, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Whitehead, P G; Jin, L; Crossman, J; Comber, S; Johnes, P J; Daldorph, P; Flynn, N; Collins, A L; Butterfield, D; Mistry, R; Bardon, R; Pope, L; Willows, R
2014-05-15
The issues of diffuse and point source phosphorus (P) pollution in the Hampshire Avon and Blashford Lakes are explored using a catchment model of the river system. A multibranch, process based, dynamic water quality model (INCA-P) has been applied to the whole river system to simulate water fluxes, total phosphorus (TP) and soluble reactive phosphorus (SRP) concentrations and ecology. The model has been used to assess impacts of both agricultural runoff and point sources from waste water treatment plants (WWTPs) on water quality. The results show that agriculture contributes approximately 40% of the phosphorus load and point sources the other 60% of the load in this catchment. A set of scenarios have been investigated to assess the impacts of alternative phosphorus reduction strategies and it is shown that a combined strategy of agricultural phosphorus reduction through either fertiliser reductions or better phosphorus management together with improved treatment at WWTPs would reduce the SRP concentrations in the river to acceptable levels to meet the EU Water Framework Directive (WFD) requirements. A seasonal strategy for WWTP phosphorus reductions would achieve significant benefits at reduced cost. Copyright © 2014 Elsevier B.V. All rights reserved.
Experimental investigation and damage assessment in a post tensioned concrete beam
NASA Astrophysics Data System (ADS)
Limongelli, Maria; Siegert, Dominique; Merliot, Erick; Waeytens, Julien; Bourquin, Frederic; Vidal, Roland; Le Corvec, Veronique; Guegen, Ivan; Cottineau, Louis-Marie
2017-04-01
This paper presents the results of an experimental campaign carried out on a prestressed concrete beam in the realm of the project SIPRIS (Systèmes Intelligents pour la Prévention des Risques Structurels), aimed to develop intelligent systems for the prevention of structural risk related to the aging of large infrastructures. The specimen was tested in several configurations aimed to re-produce several different phases of the 'life' of the beam: in the original undamaged state, under an increasing loss of tension in the cables, during and after cracking induced by a point load, after a strengthening intervention, after new cracking of the 'repaired' beam. Damage was introduced in a controlled way by means of three-point static bending tests. The transverse point loads were ap-plied at several different sections along the beam axis. Before and after each static test, the dy-namical response of the beam was measured under sine-sweep and impact tests by an extensive set of accelerometers deployed along the beam axis. The availability of both static and dynamic tests allows to investigate and compare their effectiveness to detect damages in the tensioned beam and to reliably identify the evolution of damage. The paper discusses the tests program and some results relevant to the dynamic characterization of the beam in the different phases.
Borsook, D; Erpelding, N; Lebel, A; Linnman, C; Veggeberg, R; Grant, PE; Buettner, C; Becerra, L; Burstein, R
2014-01-01
The brain responds differently to environmental and internal signals that relates to the stage of development of neural systems. While genetic and epigenetic factors contribute to a premorbid state, hormonal fluctuations in women may alter the set point of migraine. The cyclic surges of gonadal hormones may directly alter neuronal, glial and astrocyte function throughout the brain. Estrogen is mainly excitatory and progesterone inhibitory on brain neuronal systems. These changes contribute to the allostatic load of the migraine condition that most notably starts at puberty in girls. PMID:24662368
Proportional plus integral MIMO controller for regulation and tracking with anti-wind-up features
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puleston, P.F.; Mantz, R.J.
1993-11-01
A proportional plus integral matrix control structure for MIMO systems is proposed. Based on a standard optimal control structure with integral action, it permits a greater degree of independence of the design and tuning of the regulating and tracking features, without considerably increasing the controller complexity. Fast recovery from load disturbances is achieved, while large overshoots associated with set-point changes and reset wind-up problems can be reduced. A simple effective procedure for practical tuning is introduced.
Use of photostress to analyze behavior of an aft skirt test specimen
NASA Technical Reports Server (NTRS)
Gambrell, S. C., Jr.
1994-01-01
Strains at twenty-one selected points in the critical lower weld region of a aft skirt of a solid rocket booster of the shuttle were measured using photoelastic coatings and stress separator gages. Data were taken at loads of 5, 14, 20, 28, 42, 56, and 70 percent of the design limit load. Results indicate that general yielding occurred in the weld metal and for a short distance outside the fusion boundaries on either side of the weld metal. The fusion boundaries did not yield at the 70 percent load. Slight non-linearity in the load strain curves were observed at several points above the 20 percent load level. Maximum measured strains occurred at points in the forged metal of the holddown post along a line 0.50 inches from the centerline of the weld. Maximum shearing strains within the area covered by the photoelastic coating occurred at points approximately 0.33 inches to the right of the weld centerline near points 6 and 7 and lying along a yellow vertical line extending from just below point 6 to point 11. Photoelastic coatings were shown to be an excellent method to provide the whole field strain distribution in the region of the critical weld and to enhance the overall understanding of the behavior of the welded joint.
Pollution loads in urban runoff and sanitary wastewater.
Taebi, Amir; Droste, Ronald L
2004-07-05
While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha.year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control.
Hainly, R.A.; Loper, C.A.
1997-01-01
This report describes analyses of available information on nutrients and suspended sediment collected in the Lower Susquehanna River Basin during water years 1975-90. Most of the analyses were applied to data collected during water years 1980-89. The report describes the spatial and temporal availability of nutrient and suspended-sediment data and presents a preliminary concept of the spatial and temporal patterns of concentrations and loads within the basin. Where data were available, total and dissolved forms of nitrogen and phosphorus species from precipitation, surface water, ground water, and springwater, and bottom material from streams and reservoirs were evaluated. Suspended-sediment data from streams also were evaluated. The U.S. Geological Survey National Water Information System (NWIS) database was selected as the primary database for the analyses. Precipitation-quality data from the National Atmospheric Deposition Program (NADP) and bottom-material-quality data from the National Uranium Resource Evaluation (NURE) were used to supplement the water-quality data from NWIS. Concentrations of nutrients were available from 3 precipitation sites established for longterm monitoring purposes, 883 wells (854 synoptic areal survey sites and 29 project and research sites), 23 springs (17 synoptic areal survey sites and 6 project and research sites), and 894 bottom-material sites (840 synoptic areal survey sites and 54 project and research sites). Concentrations of nutrients and (or) suspended sediment were available from 128 streams (36 long-term monitoring sites, 51 synoptic areal survey sites, and 41 project and research sites). Concentrations of nutrients and suspended sediment in streams varied temporally and spatially and were related to land use, agricultural practices, and streamflow. A general north-to-south pattern of increasing median nitrate concentrations, from 2 to 5 mg/L, was detected in samples collected in study unit streams. In streams that drain areas dominated by agriculture, concentrations of nutrients and suspended sediment tend to be elevated with respect to those found in areas of other land-use types and are related to the amount of commercial fertilizer and animal manure applied to the area drained by the streams. Animal manure is the dominant source of nitrogen for the streams in the lower, agricultural part of the basin. Concentrations of nutrients in samples from wells varied with season and well depth and were related to hydrogeologic setting. Median concentrations of nitrate were 2.5 and 3.5 mg/L for wells drawing water at depths of 0 to 100 ft and 101 to 200 ft, respectively. The lowest median concentrations for nitrate in ground water from wells were generally found in siliciclastic-bedrock, forested settings of the Ridge and Valley Physiographic Province, and the highest were found in carbonate-bedrock agricultural settings of the Piedmont Physiographic Province. Twenty-five percent of the measurements from wells in carbonate rocks in the Piedmont Physiographic Province exceeded the Pennsylvania drinking-water standard. An estimate of mass balance of nutrient loads within the Lower Susquehanna River Basin was produced by combining the available information on stream loads, atmosphericdeposition loads, commercial-fertilizer applications, animal-manure production, privateseptic-system nonpoint-source loads, and municipal and industrial point-source loads. The percentage of the average annual nitrate load carried in base flow of streams in the study unit ranged from 45 to 76 percent, and the average annual phosphorus load carried in base flow ranged from 20 to 33 percent. Average annual yields of nutrients and suspended sediment from tributary basins are directly related to percentage of drainage area in agriculture and inversely to drainage area. Information required to compute loads of nitrogen and phosphorus were available for all sources except atmospheric deposition, for which only nitrogen data were available. Atmospheric deposition is the dominant source of nitrogen for the mostly forested basins draining the upper half of the study unit. The estimate of total annual nitrogen load to the study unit from precipitation is 98.8 million pounds. Nonpoint and point sources of nutrients were estimated. Nonpoint and point sources combined, including atmospheric deposition, provide a potential annual load of 390 million pounds of nitrogen and 79.5 million pounds of phosphorus. The range of percentages of the estimated nonpoint and point sources that were measured in the stream was 20 to 47 percent for nitrogen and 6 to 14 percent for phosphorus. On the average, the Susquehanna River discharges 141,000 pounds of nitrogen and 7,920 pounds of phosphorus to the Lower Susquehanna River reservoir system each year. About 98 percent of the nitrogen and 60 percent of the phosphorus passes through the reservoir system. Interpretations of available water-quality data and conclusions about the water quality of the Lower Susquehanna River Basin were limited by the scarcity of certain types of water-quality data and current ancillary data. A more complete assessment of the water quality of the basin with respect to nutrients and suspended sediment would be enhanced by the availability of additional data for multiple samples over time from all water environments; samples from streams in the northern and western part of the basin; samples from streams and springs throughout the basin during high base-flow or stormflow conditions; and information on current land-use, and nutrient loading from all types of land-use settings.
Influence of central set on anticipatory and triggered grip-force adjustments
NASA Technical Reports Server (NTRS)
Winstein, C. J.; Horak, F. B.; Fisher, B. E.; Peterson, B. W. (Principal Investigator)
2000-01-01
The effects of predictability of load magnitude on anticipatory and triggered grip-force adjustments were studied as nine normal subjects used a precision grip to lift, hold, and replace an instrumented test object. Experience with a predictable stimulus has been shown to enhance magnitude scaling of triggered postural responses to different amplitudes of perturbations. However, this phenomenon, known as a central-set effect, has not been tested systematically for grip-force responses in the hand. In our study, predictability was manipulated by applying load perturbations of different magnitudes to the test object under conditions in which the upcoming load magnitude was presented repeatedly or under conditions in which the load magnitudes were presented randomly, each with two different pre-load grip conditions (unconstrained and constrained). In constrained conditions, initial grip forces were maintained near the minimum level necessary to prevent pre-loaded object slippage, while in unconstrained conditions, no initial grip force restrictions were imposed. The effect of predictable (blocked) and unpredictable (random) load presentations on scaling of anticipatory and triggered grip responses was tested by comparing the slopes of linear regressions between the imposed load and grip response magnitude. Anticipatory and triggered grip force responses were scaled to load magnitude in all conditions. However, regardless of pre-load grip force constraint, the gains (slopes) of grip responses relative to load magnitudes were greater when the magnitude of the upcoming load was predictable than when the load increase was unpredictable. In addition, a central-set effect was evidenced by the fewer number of drop trials in the predictable relative to unpredictable load conditions. Pre-load grip forces showed the greatest set effects. However, grip responses showed larger set effects, based on prediction, when pre-load grip force was constrained to lower levels. These results suggest that anticipatory processes pertaining to load magnitude permit the response gain of both voluntary and triggered rapid grip force adjustments to be set, at least partially, prior to perturbation onset. Comparison of anticipatory set effects for reactive torque and lower extremity EMG postural responses triggered by surface translation perturbations suggests a more general rule governing anticipatory processes.
Fatigue minimising power reference control of a de-rated wind farm
NASA Astrophysics Data System (ADS)
Jensen, T. N.; Knudsen, T.; Bak, T.
2016-09-01
Modern wind farms (cluster of wind turbines) can be required to control the total power output to meet a set-point, and would then profit by minimising the structural loads and thereby the cost of energy. In this paper, we propose a new control strategy for a derated wind farm with the objective of maintaining a desired reference power production for the wind farm, while minimising the sum of fatigues on the wind turbines in steady-state. The controller outputs a vector of power references for the individual turbines. It exploits the positive correlation between fatigue and added turbulence to minimise fatigue indirectly by minimising the added turbulence. Simulated results for a wind farm with three turbines demonstrate the efficacy of the proposed solution by assessing the damage equivalent loads.
A fully redundant power hinge for LANDSAT-D appendages
NASA Technical Reports Server (NTRS)
Mamrol, F. E.; Matteo, D. N.
1981-01-01
The configuration and testing of a power driven hinge for deployment of the solar array and antenna boom for the LANDSAT-D spacecraft is discussed. The hinge is fully mechanically and electrically redundant and, thereby, can sustain a single point failure of any one motor (or its power supply), speed reducer, or bearing set without loss of its ability to function. This design utilizes the capability of the stepper motor drive to remove the flexibility of the drive train from the joint stiffness equation when the hinge is loaded against its stop. This feature precludes gapping of the joint under spacecraft maneuver loads even in the absence of a latching feature. Thus, retraction is easily accomplished by motor reversal without the need for a solenoid function to remove the latch.
An inverter/controller subsystem optimized for photovoltaic applications
NASA Technical Reports Server (NTRS)
Pickrell, R. L.; Merrill, W. C.; Osullivan, G.
1978-01-01
Conversion of solar array dc power to ac power stimulated the specification, design, and simulation testing of an inverter/controller subsystem tailored to the photovoltaic power source characteristics. This paper discusses the optimization of the inverter/controller design as part of an overall Photovoltaic Power System (PPS) designed for maximum energy extraction from the solar array. The special design requirements for the inverter/controller include: (1) a power system controller (PSC) to control continuously the solar array operating point at the maximum power level based on variable solar insolation and cell temperatures; and (2) an inverter designed for high efficiency at rated load and low losses at light loadings to conserve energy. It must be capable of operating connected to the utility line at a level set by an external controller (PSC).
Attentional sets influence perceptual load effects, but not dilution effects.
Benoni, Hanna; Zivony, Alon; Tsal, Yehoshua
2014-01-01
Perceptual load theory [Lavie, N. (1995). Perceptual load as a necessary condition for selective attention. Journal of Experimental Psychology: Human Perception and Performance, 21, 451-468.; Lavie, N., & Tsal, Y. (1994) Perceptual load as a major determinant of the locus of selection in visual attention. Perception & Psychophysics, 56, 183-197.] proposes that interference from distractors can only be avoided in situations of high perceptual load. This theory has been supported by blocked design manipulations separating low load (when the target appears alone) and high load (when the target is embedded among neutral letters). Tsal and Benoni [(2010a). Diluting the burden of load: Perceptual load effects are simply dilution effects. Journal of Experimental Psychology: Human Perception and Performance, 36, 1645-1656.; Benoni, H., & Tsal, Y. (2010). Where have we gone wrong? Perceptual load does not affect selective attention. Vision Research, 50, 1292-1298.] have recently shown that these manipulations confound perceptual load with "dilution" (the mere presence of additional heterogeneous items in high-load situations). Theeuwes, Kramer, and Belopolsky [(2004). Attentional set interacts with perceptual load in visual search. Psychonomic Bulletin & Review, 11, 697-702.] independently questioned load theory by suggesting that attentional sets might also affect distractor interference. When high load and low load were intermixed, and participants could not prepare for the presentation that followed, both the low-load and high-load trials showed distractor interference. This result may also challenge the dilution account, which proposes a stimulus-driven mechanism. In the current study, we presented subjects with both fixed and mixed blocks, including a mix of dilution trials with low-load trials and with high-load trials. We thus separated the effect of dilution from load and tested the influence of attentional sets on each component. The results revealed that whereas perceptual load effects are influenced by attentional sets, the dilution component is not. This strengthens the notion that dilution is a stimulus-driven mechanism, which enables effective selectivity.
Definition of a Robust Supervisory Control Scheme for Sodium-Cooled Fast Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ponciroli, R.; Passerini, S.; Vilim, R. B.
In this work, an innovative control approach for metal-fueled Sodium-cooled Fast Reactors is proposed. With respect to the classical approach adopted for base-load Nuclear Power Plants, an alternative control strategy for operating the reactor at different power levels by respecting the system physical constraints is presented. In order to achieve a higher operational flexibility along with ensuring that the implemented control loops do not influence the system inherent passive safety features, a dedicated supervisory control scheme for the dynamic definition of the corresponding set-points to be supplied to the PID controllers is designed. In particular, the traditional approach based onmore » the adoption of tabulated lookup tables for the set-point definition is found not to be robust enough when failures of the implemented SISO (Single Input Single Output) actuators occur. Therefore, a feedback algorithm based on the Reference Governor approach, which allows for the optimization of reference signals according to the system operating conditions, is proposed.« less
Point-of-care diagnostics: extending the laboratory network to reach the last mile.
Drain, Paul K; Rousseau, Christine
2017-03-01
More point-of-care (POC) diagnostic tests are becoming available for HIV diagnosis and treatment in resource-limited settings. These novel technologies have the potential to foster decentralized HIV care and treatment for the benefit of clinical laboratories, HIV clinics, and HIV-infected patients. There continue to be many business, technological, and operational challenges that limit product development and regulatory approval, which limits products available for the required operational and cost-effectiveness studies and delays policy adoption and implementation. Although the rapid HIV diagnostic test has been widely successful, the pathways for POC CD4 cell count and HIV viral load assay analyzers have been more challenging. We describe significant hurdles for product development, approval, and implementation, which include the business case, technical development, clinical impact, and integrating laboratory and clinical networks. The objective of this review is to highlight the obstacles for developing and implementing appropriate strategies for POC HIV testing assays to improve the clinical services for HIV-infected patients in resource-limited settings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Guodong; Ollis, Thomas B.; Xiao, Bailu
Here, this paper proposes a Mixed Integer Conic Programming (MICP) model for community microgrids considering the network operational constraints and building thermal dynamics. The proposed optimization model optimizes not only the operating cost, including fuel cost, purchasing cost, battery degradation cost, voluntary load shedding cost and the cost associated with customer discomfort due to room temperature deviation from the set point, but also several performance indices, including voltage deviation, network power loss and power factor at the Point of Common Coupling (PCC). In particular, the detailed thermal dynamic model of buildings is integrated into the distribution optimal power flow (D-OPF)more » model for the optimal operation of community microgrids. The heating, ventilation and air-conditioning (HVAC) systems can be scheduled intelligently to reduce the electricity cost while maintaining the indoor temperature in the comfort range set by customers. Numerical simulation results show the effectiveness of the proposed model and significant saving in electricity cost could be achieved with network operational constraints satisfied.« less
Liu, Guodong; Ollis, Thomas B.; Xiao, Bailu; ...
2017-10-10
Here, this paper proposes a Mixed Integer Conic Programming (MICP) model for community microgrids considering the network operational constraints and building thermal dynamics. The proposed optimization model optimizes not only the operating cost, including fuel cost, purchasing cost, battery degradation cost, voluntary load shedding cost and the cost associated with customer discomfort due to room temperature deviation from the set point, but also several performance indices, including voltage deviation, network power loss and power factor at the Point of Common Coupling (PCC). In particular, the detailed thermal dynamic model of buildings is integrated into the distribution optimal power flow (D-OPF)more » model for the optimal operation of community microgrids. The heating, ventilation and air-conditioning (HVAC) systems can be scheduled intelligently to reduce the electricity cost while maintaining the indoor temperature in the comfort range set by customers. Numerical simulation results show the effectiveness of the proposed model and significant saving in electricity cost could be achieved with network operational constraints satisfied.« less
Detection and Use of Load and Gage Output Repeats of Wind Tunnel Strain-Gage Balance Data
NASA Technical Reports Server (NTRS)
Ulbrich, N.
2017-01-01
Criteria are discussed that may be used for the detection of load and gage output repeats of wind tunnel strain-gage balance data. First, empirical thresholds are introduced that help determine if the loads or electrical outputs of a pair of balance calibration or check load data points match. A threshold of 0.01 percent of the load capacity is suggested for the identification of matching loads. Similarly, a threshold of 0.1 microV/V is recommended for the identification of matching electrical outputs. Two examples for the use of load and output repeats are discussed to illustrate benefits of the implementation of a repeat point detection algorithm in a balance data analysis software package. The first example uses the suggested load threshold to identify repeat data points that may be used to compute pure errors of the balance loads. This type of analysis may reveal hidden data quality issues that could potentially be avoided by making calibration process improvements. The second example uses the electrical output threshold for the identification of balance fouling. Data from the calibration of a six-component force balance is used to illustrate the calculation of the pure error of the balance loads.
An Evaluation of the HVAC Load Potential for Providing Load Balancing Service
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Ning
This paper investigates the potential of providing aggregated intra-hour load balancing services using heating, ventilating, and air-conditioning (HVAC) systems. A direct-load control algorithm is presented. A temperature-priority-list method is used to dispatch the HVAC loads optimally to maintain consumer-desired indoor temperatures and load diversity. Realistic intra-hour load balancing signals were used to evaluate the operational characteristics of the HVAC load under different outdoor temperature profiles and different indoor temperature settings. The number of HVAC units needed is also investigated. Modeling results suggest that the number of HVACs needed to provide a {+-}1-MW load balancing service 24 hours a day variesmore » significantly with baseline settings, high and low temperature settings, and the outdoor temperatures. The results demonstrate that the intra-hour load balancing service provided by HVAC loads meet the performance requirements and can become a major source of revenue for load-serving entities where the smart grid infrastructure enables direct load control over the HAVC loads.« less
Lee, Dae-Young; Lee, Hung; Trevors, Jack T; Weir, Susan C; Thomas, Janis L; Habash, Marc
2014-04-15
Sources of fecal water pollution were assessed in the Grand River and two of its tributaries (Ontario, Canada) using total and host-specific (human and bovine) Bacteroidales genetic markers in conjunction with reference information, such as land use and weather. In-stream levels of the markers and culturable Escherichia coli were also monitored during multiple rain events to gain information on fecal loadings to catchment from diffuse sources. Elevated human-specific marker levels were accurately identified in river water impacted by a municipal wastewater treatment plant (WWTP) effluent and at a downstream site in the Grand River. In contrast, the bovine-specific marker showed high levels of cattle fecal pollution in two tributaries, both of which are characterized as intensely farmed areas. The bovine-specific Bacteroidales marker increased with rainfall in the agricultural tributaries, indicating enhanced loading of cattle-derived fecal pollutants to river from non-point sources following rain events. However, rain-triggered fecal loading was not substantiated in urban settings, indicating continuous inputs of human-originated fecal pollutants from point sources, such as WWTP effluent. This study demonstrated that the Bacteroidales source tracking assays, in combination with land use information and hydrological data, may provide additional insight into the spatial and temporal distribution of source-specific fecal contamination in streams impacted by varying land uses. Using the approach described in this study may help to characterize impacted water sources and to design targeted land use management plans in other watersheds in the future. Copyright © 2014 Elsevier Ltd. All rights reserved.
Digital robust active control law synthesis for large order systems using constrained optimization
NASA Technical Reports Server (NTRS)
Mukhopadhyay, Vivek
1987-01-01
This paper presents a direct digital control law synthesis procedure for a large order, sampled data, linear feedback system using constrained optimization techniques to meet multiple design requirements. A linear quadratic Gaussian type cost function is minimized while satisfying a set of constraints on the design loads and responses. General expressions for gradients of the cost function and constraints, with respect to the digital control law design variables are derived analytically and computed by solving a set of discrete Liapunov equations. The designer can choose the structure of the control law and the design variables, hence a stable classical control law as well as an estimator-based full or reduced order control law can be used as an initial starting point. Selected design responses can be treated as constraints instead of lumping them into the cost function. This feature can be used to modify a control law, to meet individual root mean square response limitations as well as minimum single value restrictions. Low order, robust digital control laws were synthesized for gust load alleviation of a flexible remotely piloted drone aircraft.
Biomechanics of the incudo-malleolar-joint - Experimental investigations for quasi-static loads.
Ihrle, S; Gerig, R; Dobrev, I; Röösli, C; Sim, J H; Huber, A M; Eiber, A
2016-10-01
Under large quasi-static loads, the incudo-malleolar joint (IMJ), connecting the malleus and the incus, is highly mobile. It can be classified as a mechanical filter decoupling large quasi-static motions while transferring small dynamic excitations. This is presumed to be due to the complex geometry of the joint inducing a spatial decoupling between the malleus and incus under large quasi-static loads. Spatial Laser Doppler Vibrometer (LDV) displacement measurements on isolated malleus-incus-complexes (MICs) were performed. With the malleus firmly attached to a probe holder, the incus was excited by applying quasi-static forces at different points. For each force application point the resulting displacement was measured subsequently at different points on the incus. The location of the force application point and the LDV measurement points were calculated in a post-processing step combining the position of the LDV points with geometric data of the MIC. The rigid body motion of the incus was then calculated from the multiple displacement measurements for each force application point. The contact regions of the articular surfaces for different load configurations were calculated by applying the reconstructed motion to the geometry model of the MIC and calculate the minimal distance of the articular surfaces. The reconstructed motion has a complex spatial characteristic and varies for different force application points. The motion changed with increasing load caused by the kinematic guidance of the articular surfaces of the joint. The IMJ permits a relative large rotation around the anterior-posterior axis through the joint when a force is applied at the lenticularis in lateral direction before impeding the motion. This is part of the decoupling of the malleus motion from the incus motion in case of large quasi-static loads. Copyright © 2015 Elsevier B.V. All rights reserved.
Nutrient Loadings to Streams of the Continental United States from Municipal and Industrial Effluent
Maupin, M.A.; Ivahnenko, T.
2011-01-01
Data from the United States Environmental Protection Agency Permit Compliance System national database were used to calculate annual total nitrogen (TN) and total phosphorus (TP) loads to surface waters from municipal and industrial facilities in six major regions of the United States for 1992, 1997, and 2002. Concentration and effluent flow data were examined for approximately 118,250 facilities in 45 states and the District of Columbia. Inconsistent and incomplete discharge locations, effluent flows, and effluent nutrient concentrations limited the use of these data for calculating nutrient loads. More concentrations were reported for major facilities, those discharging more than 1million gallons per day, than for minor facilities, and more concentrations were reported for TP than for TN. Analytical methods to check and improve the quality of the Permit Compliance System data were used. Annual loads were calculated using "typical pollutant concentrations" to supplement missing concentrations based on the type and size of facilities. Annual nutrient loads for over 26,600 facilities were calculated for at least one of the three years. Sewage systems represented 74% of all TN loads and 58% of all TP loads. This work represents an initial set of data to develop a comprehensive and consistent national database of point-source nutrient loads. These loads can be used to inform a wide range of water-quality management, watershed modeling, and research efforts at multiple scales. ?? 2011 American Water Resources Association. This article is a U.S. Government work and is in the public domain in the USA.
Wear consideration in gear design for space applications
NASA Technical Reports Server (NTRS)
Akin, Lee S.; Townsend, Dennis P.
1989-01-01
A procedure is described that was developed for evaluating the wear in a set of gears in mesh under high load and low rotational speed. The method can be used for any low-speed gear application, with nearly negligible oil film thickness, and is especially useful in space stepping mechanism applications where determination of pointing error due to wear is important, such as in long life sensor antenna drives. A method is developed for total wear depth at the ends of the line of action using a very simple formula with the slide to roll ratio V sub s/V sub r. A method is also developed that uses the wear results to calculate the transmission error also known as pointing error of a gear mesh.
Thiros, Susan A.; Gerner, Steven J.
2015-01-01
Irrigation improvements began to be implemented in 2007 to reduce dissolved-solids loads discharged from the MWSP area. The theoretical annual net dissolved-solids load where the cumulative NRCS calculated dissolved-solids load reduction is added to the net MWSP dissolved-solids load is what would be expected if there was no irrigation improvement in the area associated with the MWSP. The theoretical data points lie very near the baseline representing the pre-MWSP dissolved-solids load to canal streamflow relation. The proximity of the theoretical data points to the baseline shows that the NRCS calculations of reduction in dissolved-solids load are generally supported by the data collected during this study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aho, Jacob; Pao, Lucy Y.; Fleming, Paul
2014-11-13
As wind energy becomes a larger portion of the world's energy portfolio there has been an increased interest for wind turbines to control their active power output to provide ancillary services which support grid reliability. One of these ancillary services is the provision of frequency regulation, also referred to as secondary frequency control or automatic generation control (AGC), which is often procured through markets which recently adopted performance-based compensation. A wind turbine with a control system developed to provide active power ancillary services can be used to provide frequency regulation services. Simulations have been performed to determine the AGC trackingmore » performance at various power schedule set-points, participation levels, and wind conditions. The performance metrics used in this study are based on those used by several system operators in the US. Another metric that is analyzed is the damage equivalent loads (DELs) on turbine structural components, though the impacts on the turbine electrical components are not considered. The results of these single-turbine simulations show that high performance scores can be achieved when there are insufficient wind resources available. The capability of a wind turbine to rapidly and accurately follow power commands allows for high performance even when tracking rapidly changing AGC signals. As the turbine de-rates to meet decreased power schedule set-points there is a reduction in the DELs, and the participation in frequency regulation has a negligible impact on these loads.« less
Klatt, Nichole R.; Villinger, Francois; Bostik, Pavel; Gordon, Shari N.; Pereira, Lara; Engram, Jessica C.; Mayne, Ann; Dunham, Richard M.; Lawson, Benton; Ratcliffe, Sarah J.; Sodora, Donald L.; Else, James; Reimann, Keith; Staprans, Silvija I.; Haase, Ashley T.; Estes, Jacob D.; Silvestri, Guido; Ansari, Aftab A.
2008-01-01
Naturally SIV-infected sooty mangabeys (SMs) remain asymptomatic despite high virus replication. Elucidating the mechanisms underlying AIDS resistance of SIV-infected SMs may provide crucial information to better understand AIDS pathogenesis. In this study, we assessed the determinants of set-point viremia in naturally SIV-infected SMs, i.e., immune control of SIV replication versus target cell limitation. We depleted CD4+ T cells in 6 naturally SIV-infected SMs by treating with humanized anti-CD4 mAb (Cdr-OKT4A-huIgG1). CD4+ T cells were depleted almost completely in blood and BM and at variable levels in mucosal tissues and LNs. No marked depletion of CD14+ monocytes was observed. Importantly, CD4+ T cell depletion was associated with a rapid, significant decline in viral load, which returned to baseline level at day 30–45, coincident with an increased fraction of proliferating and activated CD4+ T cells. Throughout the study, virus replication correlated with the level of proliferating CD4+ T cells. CD4+ T cell depletion did not induce any changes in the fraction of Tregs or the level of SIV-specific CD8+ T cells. Our results suggest that the availability of activated CD4+ T cells, rather than immune control of SIV replication, is the main determinant of set-point viral load during natural SIV infection of SMs. PMID:18497876
Orthodontic intrusion of maxillary incisors: a 3D finite element method study
Saga, Armando Yukio; Maruo, Hiroshi; Argenta, Marco André; Maruo, Ivan Toshio; Tanaka, Orlando Motohiro
2016-01-01
Objective: In orthodontic treatment, intrusion movement of maxillary incisors is often necessary. Therefore, the objective of this investigation is to evaluate the initial distribution patterns and magnitude of compressive stress in the periodontal ligament (PDL) in a simulation of orthodontic intrusion of maxillary incisors, considering the points of force application. Methods: Anatomic 3D models reconstructed from cone-beam computed tomography scans were used to simulate maxillary incisors intrusion loading. The points of force application selected were: centered between central incisors brackets (LOAD 1); bilaterally between the brackets of central and lateral incisors (LOAD 2); bilaterally distal to the brackets of lateral incisors (LOAD 3); bilaterally 7 mm distal to the center of brackets of lateral incisors (LOAD 4). Results and Conclusions: Stress concentrated at the PDL apex region, irrespective of the point of orthodontic force application. The four load models showed distinct contour plots and compressive stress values over the midsagittal reference line. The contour plots of central and lateral incisors were not similar in the same load model. LOAD 3 resulted in more balanced compressive stress distribution. PMID:27007765
Preliminary results for model identification in characterizing 2-D topographic road profiles
NASA Astrophysics Data System (ADS)
Kern, Joshua V.; Ferris, John B.
2006-05-01
Load data representing severe customer usage is needed throughout a chassis development program; the majority of these chassis loads originate with the excitation from the road. These chassis loads are increasingly derived from vehicle simulations. Simulating a vehicle traversing long roads is simply impractical, however, and a greatly reduced set of characteristic roads must be found. In order to characterize a road, certain modeling assumptions must be made. Several models have been proposed making various assumptions about the properties that road profiles possess. The literature in this field is reviewed before focusing on two modeling assumptions of particular interest: the stationarity of the signal (homogeneity of the road) and the corresponding interval over which previous data points are correlated to the current data point. In this work, 2-D topographic road profiles are considered to be signals that are realizations of a stochastic process. The objective of this work is to investigate the stationarity assumption and the interval of influence for several carefully controlled sections of highway pavement in the United States. Two statistical techniques are used in analyzing these data: the autocorrelation and the partial autocorrelation. It is shown that the road profile signals in their original form are not stationary and have an extremely long interval of influence on the order of 25m. By differencing the data, however, it is often possible to generate stationary residuals and a very short interval of influence on the order of 250mm. By examining the autocorrelation and the partial autocorrelation, various versions of ARIMA models appear to be appropriate for further modeling. Implications to modeling the signals as Markov Chains are also discussed. In this way, roads can be characterized by the model architecture and the particular parameterization of the model. Any synthetic road realized from a particular model represents all profiles in this set. Realizations of any length can be generated, allowing efficient simulation and timely information about the chassis loads that can be used for design decisions. This work provides insights for future development in the modeling and characterization of 2-D topographic road profiles.
1991-12-01
ei a. "h:2 ;.::,e :v a :ei.w co±’eague. CAct. Alien Andrews. SAF. who s*_ese_ . zne tere in mod i: at:ons ch he m i emen tec tha nabed "he :CT -L work...program by entering: SET COMMAND SYS $SYSTEM:SAVE85 i0. Load the LOAD85 program by entering: SET COMMAND SYS $SYSTEM:LOAD85 11. Connect the VT340 with the...SYSINT CUROFF 4. Load the LOAD85 program by entering: SET COMMAND SYS $SYSTEM:LOAD85 5. Display the image to be printed on the screen by entering: LOAD85
Creep Behavior of High-Strength Concrete Subjected to Elevated Temperatures.
Yoon, Minho; Kim, Gyuyong; Kim, Youngsun; Lee, Taegyu; Choe, Gyeongcheol; Hwang, Euichul; Nam, Jeongsoo
2017-07-11
Strain is generated in concrete subjected to elevated temperatures owing to the influence of factors such as thermal expansion and design load. Such strains resulting from elevated temperatures and load can significantly influence the stability of a structure during and after a fire. In addition, the lower the water-to-binder (W-B) ratio and the smaller the quantity of aggregates in high-strength concrete, the more likely it is for unstable strain to occur. Hence, in this study, the compressive strength, elastic modulus, and creep behavior were evaluated at target temperatures of 100, 200, 300, 500, and 800 °C for high-strength concretes with W-B ratios of 30%, 26%, and 23%. The loading conditions were set as non-loading and 0.33f cu . It was found that as the compressive strength of the concrete increased, the mechanical characteristics deteriorated and transient creep increased. Furthermore, when the point at which creep strain occurred at elevated temperatures after the occurrence of transient creep was considered, greater shrinkage strain occurred as the compressive strength of the concrete increased. At a heating temperature of 800 °C, the 80 and 100 MPa test specimens showed creep failure within a shrinkage strain range similar to the strain at the maximum load.
Creep Behavior of High-Strength Concrete Subjected to Elevated Temperatures
Yoon, Minho; Kim, Gyuyong; Kim, Youngsun; Lee, Taegyu; Choe, Gyeongcheol; Hwang, Euichul; Nam, Jeongsoo
2017-01-01
Strain is generated in concrete subjected to elevated temperatures owing to the influence of factors such as thermal expansion and design load. Such strains resulting from elevated temperatures and load can significantly influence the stability of a structure during and after a fire. In addition, the lower the water-to-binder (W–B) ratio and the smaller the quantity of aggregates in high-strength concrete, the more likely it is for unstable strain to occur. Hence, in this study, the compressive strength, elastic modulus, and creep behavior were evaluated at target temperatures of 100, 200, 300, 500, and 800 °C for high-strength concretes with W–B ratios of 30%, 26%, and 23%. The loading conditions were set as non-loading and 0.33fcu. It was found that as the compressive strength of the concrete increased, the mechanical characteristics deteriorated and transient creep increased. Furthermore, when the point at which creep strain occurred at elevated temperatures after the occurrence of transient creep was considered, greater shrinkage strain occurred as the compressive strength of the concrete increased. At a heating temperature of 800 °C, the 80 and 100 MPa test specimens showed creep failure within a shrinkage strain range similar to the strain at the maximum load. PMID:28773144
Carroll, Kathryn A; Samek, Anya; Zepeda, Lydia
2018-02-01
Displaying bundles of healthy foods at the grocery store is a health nudge that simplifies shopping and may have the potential for increasing fruit and vegetable (F&V) purchasing. To evaluate the impact of food bundling, we conduct an artefactual field experiment with community participants in a laboratory set up as a grocery store. Dual-self theory suggests that food choices may differ depending on whether shoppers are under cognitive load - in our experiment, we exogenously vary whether bundles are displayed (with and without a price discount) and whether shoppers are under cognitive load. Our findings align with prior studies that suggest unhealthy options are more likely to be selected when cognitive resources are constrained. When bundles are displayed, we observe increased F&V purchasing. We also observe a significant interaction between cognitive load and price discounting. We find discounted bundles are more effective in the absence of cognitive load, but non-discounted bundles are more effective when shoppers are under cognitive load. Although more research is warranted, our findings suggest that when shopping under cognitive load, it is possible that discounts impose additional cognitive strain on the shopping experience. For retailers and policymakers, our results point to the potential power of bundling as a strategy for increasing healthy food purchasing. Copyright © 2017 Elsevier Ltd. All rights reserved.
Analysis of recurrent neural networks for short-term energy load forecasting
NASA Astrophysics Data System (ADS)
Di Persio, Luca; Honchar, Oleksandr
2017-11-01
Short-term forecasts have recently gained an increasing attention because of the rise of competitive electricity markets. In fact, short-terms forecast of possible future loads turn out to be fundamental to build efficient energy management strategies as well as to avoid energy wastage. Such type of challenges are difficult to tackle both from a theoretical and applied point of view. Latter tasks require sophisticated methods to manage multidimensional time series related to stochastic phenomena which are often highly interconnected. In the present work we first review novel approaches to energy load forecasting based on recurrent neural network, focusing our attention on long/short term memory architectures (LSTMs). Such type of artificial neural networks have been widely applied to problems dealing with sequential data such it happens, e.g., in socio-economics settings, for text recognition purposes, concerning video signals, etc., always showing their effectiveness to model complex temporal data. Moreover, we consider different novel variations of basic LSTMs, such as sequence-to-sequence approach and bidirectional LSTMs, aiming at providing effective models for energy load data. Last but not least, we test all the described algorithms on real energy load data showing not only that deep recurrent networks can be successfully applied to energy load forecasting, but also that this approach can be extended to other problems based on time series prediction.
Experimental studies on fatigue behavior of macro fiber composite (MFC) under mechanical loading
NASA Astrophysics Data System (ADS)
Pandey, Akash; Arockiarajan, A.
2016-04-01
Macro fiber Composite (MFC) finds its application in active control, vibration control and sensing elements. MFC can be laminated to surfaces or embedded in the structures to be used as an actuator and sensors. Due to its attractive properties and applications, it may be subjected to continuous loading, which leads to the deterioration of the properties. This study is focused on the fatigue lifetime of MFC under tensile and compressive loading at room temperature. Experiments were performed using 4 point bending setup, with MFC pasted at the center of the mild steel beam, to maintain constant bending stress along MFC. MFC is pasted using vacuum bagging technique. Sinusoidal loading is given to sample while maintaining R=0.13 (for tensile testing) and R=10 (for compressive testing). For d31 and d33 type of MFC, test was conducted for the strain values of 727 μ strain, 1400 μ strain, 1700 μ strain and 1900 μ strain for fatigue under tensile loading. For fatigue under compressive loading, both d33 and d31, was subjected to minimum strain of -2000 μ strain. Decrease in the slope of dielectric displacement vs. strain is the measure for the degradation. 10 percent decrease in the slope is set as the failure criteria. Experimental results show that MFC is very reliable below 1700 μ strain (R=0.13) at the room temperature.
Realworld maximum power point tracking simulation of PV system based on Fuzzy Logic control
NASA Astrophysics Data System (ADS)
Othman, Ahmed M.; El-arini, Mahdi M. M.; Ghitas, Ahmed; Fathy, Ahmed
2012-12-01
In the recent years, the solar energy becomes one of the most important alternative sources of electric energy, so it is important to improve the efficiency and reliability of the photovoltaic (PV) systems. Maximum power point tracking (MPPT) plays an important role in photovoltaic power systems because it maximize the power output from a PV system for a given set of conditions, and therefore maximize their array efficiency. This paper presents a maximum power point tracker (MPPT) using Fuzzy Logic theory for a PV system. The work is focused on the well known Perturb and Observe (P&O) algorithm and is compared to a designed fuzzy logic controller (FLC). The simulation work dealing with MPPT controller; a DC/DC Ćuk converter feeding a load is achieved. The results showed that the proposed Fuzzy Logic MPPT in the PV system is valid.
Willardson, Jeffrey M; Simão, Roberto; Fontana, Fabio E
2012-11-01
The purpose of this study was to compare 4 different loading schemes for the free weight bench press, wide grip front lat pull-down, and free weight back squat to determine the extent of progressive load reductions necessary to maintain repetition performance. Thirty-two recreationally trained women (age = 29.34 ± 4.58 years, body mass = 59.61 ± 4.72 kg, height = 162.06 ± 4.04 cm) performed 4 resistance exercise sessions that involved 3 sets of the free weight bench press, wide grip front lat pull-down, and free weight back squat, performed in this exercise order during all 4 sessions. Each of the 4 sessions was conducted under different randomly ordered loading schemes, including (a) a constant 10 repetition maximum (RM) load for all 3 sets and for all 3 exercises, (b) a 5% reduction after the first and second sets for all the 3 exercises, (c) a 10% reduction after the first and second sets for all the 3 exercises, and (d) a 15% reduction after the first and second sets for all the 3 exercises. The results indicated that for the wide grip front lat pull-down and free weight back squat, a 10% load reduction was necessary after the first and second sets to accomplish 10 repetitions on all the 3 sets. For the free weight bench press, a load reduction between 10 and 15% was necessary; specifically, a 10% reduction was insufficient and a 15% reduction was excessive, as evidenced by significantly >10 repetitions on the second and third sets for this exercise (p ≤ 0.05). In conclusion, the results of this study indicate that a resistance training prescription that involves 1-minute rest intervals between multiple 10RM sets does require load reductions to maintain repetition performance. Practitioners might apply these results by considering an approximate 10% load reduction after the first and second sets for the exercises examined, when training women of similar characteristics as in this study.
Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F
2015-02-01
To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA-LC-DCP fixation (116,274 ± 13,211) was significantly greater than that of the AO-LC-DCP fixation 47,619 ± 6580. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad HA-LC-DCP fixation compared with the AO-LC-DCP fixation. In single cycle to failure under torsion, mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, were: yield load, 101.3 ± 14.68 and 70.54 ± 10.20 N-m; composite rigidity, 437.9 ± 32.9 and 220.7 ± 17.6 N-m/rad; and failure load: 105.7 ± 15.5 and 75.28 ± 10.1 N-m. HA-LC-DCP was superior to AO-LC-DCP in resisting the static overload forces (palmarodorsal 4 point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4 point bending. © Copyright 2014 by The American College of Veterinary Surgeons.
Novel Musculoskeletal Loading and Assessment System
NASA Technical Reports Server (NTRS)
Downs, Meghan E.
2017-01-01
Ground based and ISS (International Space Station) exercise research have shown that axial loading via two-point loading at the shoulders and load quality (i.e. consistent load and at least 1:1 concentric to eccentric ratio) are extremely important to optimize musculoskeletal adaptations to resistance exercise. The Advanced Resistance Exercise Device (ARED) is on ISS now and is the "state of the art" for resistance exercise capabilities in microgravity; however, the ARED is far too large and power consuming for exploration vehicles. The single cable exercise device design selected for MPCV (Multi-Purpose Crew Vehicle), does not readily allow for the two-point loading at the shoulders.
Defining Exercise Performance Metrics for Flight Hardware Development
NASA Technical Reports Server (NTRS)
Beyene, Nahon M.
2004-01-01
The space industry has prevailed over numerous design challenges in the spirit of exploration. Manned space flight entails creating products for use by humans and the Johnson Space Center has pioneered this effort as NASA's center for manned space flight. NASA Astronauts use a suite of flight exercise hardware to maintain strength for extravehicular activities and to minimize losses in muscle mass and bone mineral density. With a cycle ergometer, treadmill, and the Resistive Exercise Device available on the International Space Station (ISS), the Space Medicine community aspires to reproduce physical loading schemes that match exercise performance in Earth s gravity. The resistive exercise device presents the greatest challenge with the duty of accommodating 20 different exercises and many variations on the core set of exercises. This paper presents a methodology for capturing engineering parameters that can quantify proper resistive exercise performance techniques. For each specified exercise, the method provides engineering parameters on hand spacing, foot spacing, and positions of the point of load application at the starting point, midpoint, and end point of the exercise. As humans vary in height and fitness levels, the methodology presents values as ranges. In addition, this method shows engineers the proper load application regions on the human body. The methodology applies to resistive exercise in general and is in use for the current development of a Resistive Exercise Device. Exercise hardware systems must remain available for use and conducive to proper exercise performance as a contributor to mission success. The astronauts depend on exercise hardware to support extended stays aboard the ISS. Future plans towards exploration of Mars and beyond acknowledge the necessity of exercise. Continuous improvement in technology and our understanding of human health maintenance in space will allow us to support the exploration of Mars and the future of space exploration.
Herbeck, Joshua T.; Mittler, John E.; Gottlieb, Geoffrey S.; Mullins, James I.
2014-01-01
Trends in HIV virulence have been monitored since the start of the AIDS pandemic, as studying HIV virulence informs our understanding of HIV epidemiology and pathogenesis. Here, we model changes in HIV virulence as a strictly evolutionary process, using set point viral load (SPVL) as a proxy, to make inferences about empirical SPVL trends from longitudinal HIV cohorts. We develop an agent-based epidemic model based on HIV viral load dynamics. The model contains functions for viral load and transmission, SPVL and disease progression, viral load trajectories in multiple stages of infection, and the heritability of SPVL across transmissions. We find that HIV virulence evolves to an intermediate level that balances infectiousness with longer infected lifespans, resulting in an optimal SPVL∼4.75 log10 viral RNA copies/mL. Adaptive viral evolution may explain observed HIV virulence trends: our model produces SPVL trends with magnitudes that are broadly similar to empirical trends. With regard to variation among studies in empirical SPVL trends, results from our model suggest that variation may be explained by the specific epidemic context, e.g. the mean SPVL of the founding lineage or the age of the epidemic; or improvements in HIV screening and diagnosis that results in sampling biases. We also use our model to examine trends in community viral load, a population-level measure of HIV viral load that is thought to reflect a population's overall transmission potential. We find that community viral load evolves in association with SPVL, in the absence of prevention programs such as antiretroviral therapy, and that the mean community viral load is not necessarily a strong predictor of HIV incidence. PMID:24945322
Deflection load characteristics of laser-welded orthodontic wires.
Watanabe, Etsuko; Stigall, Garrett; Elshahawy, Waleed; Watanabe, Ikuya
2012-07-01
To compare the deflection load characteristics of homogeneous and heterogeneous joints made by laser welding using various types of orthodontic wires. Four kinds of straight orthodontic rectangular wires (0.017 inch × 0.025 inch) were used: stainless-steel (SS), cobalt-chromium-nickel (Co-Cr-Ni), beta-titanium alloy (β-Ti), and nickel-titanium (Ni-Ti). Homogeneous and heterogeneous end-to-end joints (12 mm long each) were made by Nd:YAG laser welding. Two types of welding methods were used: two-point welding and four-point welding. Nonwelded wires were also used as a control. Deflection load (N) was measured by conducting the three-point bending test. The data (n = 5) were statistically analyzed using analysis of variance/Tukey test (P < .05). The deflection loads for control wires measured were as follows: SS: 21.7 ± 0.8 N; Co-Cr-Ni: 20.0 ± 0.3 N; β-Ti: 13.9 ± 1.3 N; and Ni-Ti: 6.6 ± 0.4 N. All of the homogeneously welded specimens showed lower deflection loads compared to corresponding control wires and exhibited higher deflection loads compared to heterogeneously welded combinations. For homogeneous combinations, Co-Cr-Ni/Co-Cr-Ni showed a significantly (P < .05) higher deflection load than those of the remaining homogeneously welded groups. In heterogeneous combinations, SS/Co-Cr-Ni and β-Ti/Ni-Ti showed higher deflection loads than those of the remaining heterogeneously welded combinations (significantly higher for SS/Co-Cr-Ni). Significance (P < .01) was shown for the interaction between the two factors (materials combination and welding method). However, no significant difference in deflection load was found between four-point and two-point welding in each homogeneous or heterogeneous combination. Heterogeneously laser-welded SS/Co-Cr-Ni and β-Ti/Ni-Ti wires provide a deflection load that is comparable to that of homogeneously welded orthodontic wires.
Thermoviscoplastic analysis of fibrous periodic composites using triangular subvolumes
NASA Technical Reports Server (NTRS)
Walker, Kevin P.; Freed, Alan D.; Jordan, Eric H.
1993-01-01
The nonlinear viscoplastic behavior of fibrous periodic composites is analyzed by discretizing the unit cell into triangular subvolumes. A set of these subvolumes can be configured by the analyst to construct a representation for the unit cell of a periodic composite. In each step of the loading history, the total strain increment at any point is governed by an integral equation which applies to the entire composite. A Fourier series approximation allows the incremental stresses and strains to be determined within a unit cell of the periodic lattice. The nonlinearity arising from the viscoplastic behavior of the constituent materials comprising the composite is treated as fictitious body force in the governing integral equation. Specific numerical examples showing the stress distributions in the unit cell of a fibrous tungsten/copper metal matrix composite under viscoplastic loading conditions are given. The stress distribution resulting in the unit cell when the composite material is subjected to an overall transverse stress loading history perpendicular to the fibers is found to be highly heterogeneous, and typical homogenization techniques based on treating the stress and strain distributions within the constituent phases as homogeneous result in large errors under inelastic loading conditions.
Thermoviscoplastic analysis of fibrous periodic composites by the use of triangular subvolumes
NASA Technical Reports Server (NTRS)
Walker, Kevin P.; Freed, Alan D.; Jordan, Eric H.
1994-01-01
The non-linear viscoplastic behavior of fibrous periodic composites is analyzed by discretizing the unit cell into triangular subvolumes. A set of these subvolumes can be configured by the analyst to construct a representation for the unit cell of a periodic composite. In each step of the loading history the total strain increment at any point is governed by an integral equation which applies to the entire composite. A Fourier series approximation allows the incremental stresses and strains to be determined within a unit cell of the periodic lattice. The non-linearity arising from the viscoplastic behavior of the constituent materials comprising the composite is treated as a fictitious body force in the governing integral equation. Specific numerical examples showing the stress distributions in the unit cell of a fibrous tungsten/copper metal-matrix composite under viscoplastic loading conditions are given. The stress distribution resulting in the unit cell when the composite material is subjected to an overall transverse stress loading history perpendicular to the fibers is found to be highly heterogeneous, and typical homogenization techniques based on treating the stress and strain distributions within the constituent phases as homogeneous result in large errors under inelastic loading conditions.
Static and fatigue mechanical behavior of three dental CAD/CAM ceramics.
Homaei, Ehsan; Farhangdoost, Khalil; Tsoi, James Kit Hon; Matinlinna, Jukka Pekka; Pow, Edmond Ho Nang
2016-06-01
The aim of this study was to measure the mechanical properties and fatigue behavior of three contemporary used dental ceramics, zirconia Cercon(®) (ZC), lithium disilicate e.max(®) CAD (LD), and polymer-infiltrated ceramic Enamic(®) (PIC). Flexural strength of each CAD/CAM ceramic was measured by three point bending (n=15) followed by Weibull analysis. Elastic modulus was calculated from the load-displacement curve. For cyclic fatigue loading, sinusoidal loading with a frequency of 8Hz with minimum load 3N were applied to these ceramics (n=24) using three point bending from 10(3) to 10(6) cycles. Fatigue limits of these ceramics were predicted with S-N fatigue diagram. Fracture toughness and Vickers hardness of the ceramics were measured respectively by single edge V-notch beam (SEVNB) and microindentation (Hv 0.2) methods. Chemical compositions of the materials׳ surfaces were analyzed by EDS, and microstructural analysis was conducted on the fracture surfaces by SEM. One-way ANOVA was performed and the level of significance was set at 0.05 to analyze the numerical results. The mean flexural strength of ZC, LD, and PIC was respectively 886.9, 356.7, and 135.8MPa. However, the highest Weibull modulus belonged to PIC with 19.7 and the lowest was found in LD with 7.0. The fatigue limit of maximum load for one million cycles of ZC, LD, and PIC was estimated to be 500.1, 168.4, and 73.8GPa. The mean fracture toughness of ZC, LD, and PIC was found to be respectively 6.6, 2.8, and 1.4MPam(1/2), while the mean Vickers hardness was 1641.7, 676.7, and 261.7Hv. Fracture surfaces followed fatigue loading appeared to be smoother than that after monotonic loading. Mechanical properties of ZC were substantially superior to the two other tested ceramics, but the scattering of data was the least in PIC. The fatigue limit was found to be approximately half of the mean flexural strength for all tested ceramics. Copyright © 2016 Elsevier Ltd. All rights reserved.
Combination Space Station Handrail Clamp and Pointing Device
NASA Technical Reports Server (NTRS)
Hughes, Stephen J. (Inventor)
1999-01-01
A device for attaching an experiment carrier to a space station handrail is provided. The device has two major components, a clamping mechanism for attachment to a space station handrail, and a pointing carrier on which an experiment package can be mounted and oriented. The handrail clamp uses an overcenter mechanism and the carrier mechanism uses an adjustable preload ball and socket for carrier positioning. The handrail clamp uses a stack of disk springs to provide a spring loaded button. This configuration provides consistent clamping force over a range of possible handrail thicknesses. Three load points are incorporated in the clamping mechanism thereby spreading the clamping load onto three separate points on the handrail. A four bar linkage is used to provide for a single actuation lever for all three load points. For additional safety, a secondary lock consisting of a capture plate and push lock keeps the clamp attached to the handrail in the event of main clamp failure. For the carrier positioning mechanism, a ball in a spring loaded socket uses friction to provide locking torque; however. the ball and socket are torque limited so that the ball ran slip under kick loads (125 pounds or greater). A lead screw attached to disk spring stacks is used to provide an adjustable spring force on the socket. A locking knob is attached to the lead screw to allow for hand manipulation of the lead screw.
NASA Astrophysics Data System (ADS)
Wang, H.; Chen, K.; Wu, Z.; Guan, X.
2017-12-01
In recent years, with the prominent of water environment problem and the relative increase of point source pollution governance, especially the agricultural non-point source pollution problem caused by the extensive use of fertilizers and pesticides has become increasingly aroused people's concern and attention. In order to reveal the quantitative relationship between agriculture water and fertilizer and non-point source pollution, on the basis of elm field experiment and combined with agricultural drainage irrigation model, the agricultural irrigation water and the relationship between fertilizer and fertilization scheme and non-point source pollution were analyzed and calculated by field emission intensity index. The results show that the variation of displacement varies greatly under different irrigation conditions. When the irrigation water increased from 22cm to 42cm, the irrigation water increased by 20 cm while the field displacement increased by 11.92 cm, about 66.22% of the added value of irrigation water. Then the irrigation water increased from 42 to 68, irrigation water increased 26 cm, and the field displacement increased by 22.48 cm, accounting for 86.46% of irrigation water. So there is an "inflection point" between the irrigation water amount and field displacement amount. The load intensity increases with the increase of irrigation water and shows a significant power correlation. Under the different irrigation condition, the increase amplitude of load intensity with the increase of irrigation water is different. When the irrigation water is smaller, the load intensity increase relatively less, and when the irrigation water increased to about 42 cm, the load intensity will increase considerably. In addition, there was a positive correlation between the fertilization and load intensity. The load intensity had obvious difference in different fertilization modes even with same fertilization level, in which the fertilizer field unit load intensity increased the most in July. The results provide some basis for the field control and management of agricultural non-point source pollution.
Apportioning riverine DIN load to export coefficients of land uses in an urbanized watershed.
Shih, Yu-Ting; Lee, Tsung-Yu; Huang, Jr-Chuan; Kao, Shuh-Ji; Chang
2016-08-01
The apportionment of riverine dissolved inorganic nitrogen (DIN) load to individual land use on a watershed scale demands the support of accurate DIN load estimation and differentiation of point and non-point sources, but both of them are rarely quantitatively determined in small montane watersheds. We introduced the Danshui River watershed of Taiwan, a mountainous urbanized watershed, to determine the export coefficients via a reverse Monte Carlo approach from riverine DIN load. The results showed that the dynamics of N fluctuation determines the load estimation method and sampling frequency. On a monthly sampling frequency basis, the average load estimation of the methods (GM, FW, and LI) outperformed that of individual method. Export coefficient analysis showed that the forest DIN yield of 521.5kg-Nkm(-2)yr(-1) was ~2.7-fold higher than the global riverine DIN yield (mainly from temperate large rivers with various land use compositions). Such a high yield was attributable to high rainfall and atmospheric N deposition. The export coefficient of agriculture was disproportionately larger than forest suggesting that a small replacement of forest to agriculture could lead to considerable change of DIN load. The analysis of differentiation between point and non-point sources showed that the untreated wastewater (non-point source), accounting for ~93% of the total human-associated wastewater, resulted in a high export coefficient of urban. The inclusion of the treated and untreated wastewater completes the N budget of wastewater. The export coefficient approach serves well to assess the riverine DIN load and to improve the understanding of N cascade. Copyright © 2016 Elsevier B.V. All rights reserved.
Composite-Material Point-Stress Analysis
NASA Technical Reports Server (NTRS)
Spears, F., S.
1982-01-01
PSANAL computes composite-laminate elastic and thermal properties and allowable load levels for any combination of applied membrane and bending loads occurring at a point. Basic linear orthotropic stress/ strain relationships and standard composite-laminate theory formulas are utilized.
A generalized force-modified potential energy surface (G-FMPES) for mechanochemical simulations
Subramanian, Gopinath; Mathew, Nithin; Leiding, Jeffery A.
2015-10-05
We describe the modifications that a spatially varying external load produces on a Born-Oppenheimer potential energy surface (PES) by calculating static quantities of interest. The effects of the external loads are exemplified using electronic structure calculations (at the HF/6-31G** level) of two different molecules: ethane and hexahydro-1,3,5-trinitro-s-triazine (RDX). The calculated transition states and The Hessian matrices of stationary points show that spatially varying external loads shift the stationary points and modify the curvature of the PES, thereby affecting the harmonic transition rates by altering both the energy barrier as well as the prefactor. The harmonic spectra of both molecules aremore » blue-shifted with increasing compressive “pressure.” Some stationary points on the RDX-PES disappear under application of the external load, indicating the merging of an energy minimum with a saddle point.« less
Measurement of Gear Tooth Dynamic Friction
NASA Technical Reports Server (NTRS)
Rebbechi, Brian; Oswald, Fred B.; Townsend, Dennis P.
1996-01-01
Measurements of dynamic friction forces at the gear tooth contact were undertaken using strain gages at the root fillets of two successive teeth. Results are presented from two gear sets over a range of speeds and loads. The results demonstrate that the friction coefficient does not appear to be significantly influenced by the sliding reversal at the pitch point, and that the friction coefficient values found are in accord with those in general use. The friction coefficient was found to increase at low sliding speeds. This agrees with the results of disc machine testing.
Grimbergen, M C M; van Swol, C F P; Kendall, C; Verdaasdonk, R M; Stone, N; Bosch, J L H R
2010-01-01
The overall quality of Raman spectra in the near-infrared region, where biological samples are often studied, has benefited from various improvements to optical instrumentation over the past decade. However, obtaining ample spectral quality for analysis is still challenging due to device requirements and short integration times required for (in vivo) clinical applications of Raman spectroscopy. Multivariate analytical methods, such as principal component analysis (PCA) and linear discriminant analysis (LDA), are routinely applied to Raman spectral datasets to develop classification models. Data compression is necessary prior to discriminant analysis to prevent or decrease the degree of over-fitting. The logical threshold for the selection of principal components (PCs) to be used in discriminant analysis is likely to be at a point before the PCs begin to introduce equivalent signal and noise and, hence, include no additional value. Assessment of the signal-to-noise ratio (SNR) at a certain peak or over a specific spectral region will depend on the sample measured. Therefore, the mean SNR over the whole spectral region (SNR(msr)) is determined in the original spectrum as well as for spectra reconstructed from an increasing number of principal components. This paper introduces a method of assessing the influence of signal and noise from individual PC loads and indicates a method of selection of PCs for LDA. To evaluate this method, two data sets with different SNRs were used. The sets were obtained with the same Raman system and the same measurement parameters on bladder tissue collected during white light cystoscopy (set A) and fluorescence-guided cystoscopy (set B). This method shows that the mean SNR over the spectral range in the original Raman spectra of these two data sets is related to the signal and noise contribution of principal component loads. The difference in mean SNR over the spectral range can also be appreciated since fewer principal components can reliably be used in the low SNR data set (set B) compared to the high SNR data set (set A). Despite the fact that no definitive threshold could be found, this method may help to determine the cutoff for the number of principal components used in discriminant analysis. Future analysis of a selection of spectral databases using this technique will allow optimum thresholds to be selected for different applications and spectral data quality levels.
Minimum airflow reset of single-duct VAV terminal boxes
NASA Astrophysics Data System (ADS)
Cho, Young-Hum
Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and applied to actual systems for performance validation. The results of the theoretical analysis, numeric simulations, and experiments show that the optimal control algorithms can automatically identify the minimum rate of heating airflow under actual working conditions. Improved control helps to stabilize room air temperatures. The vertical difference in the room air temperature was lower than the comfort value. Measurements of room CO2 levels indicate that when the minimum airflow set point was reduced it did not adversely affect the indoor air quality. According to the measured energy results, optimal control algorithms give a lower rate of reheating energy consumption than conventional controls.
Barcellona, Massimo G; Morrissey, Matthew C
2016-04-01
The commonly used open kinetic chain knee extensor (OKCKE) exercise loads the sagittal restraints to knee anterior tibial translation. To investigate the effect of different loads of OKCKE resistance training on anterior knee laxity (AKL) in the uninjured knee. non-clinical trial. Randomization into one of three supervised training groups occurred with training 3 times per week for 12 weeks. Subjects in the LOW and HIGH groups performed OKCKE resistance training at loads of 2 sets of 20 repetition maximum (RM) and 20 sets of 2RM, respectively. Subjects in the isokinetic training group (ISOK) performed isokinetic OKCKE resistance training using 2 sets of 20 maximal efforts. AKL was measured using the KT2000 arthrometer with concurrent measurement of lateral hamstrings muscle activity at baseline, 6 weeks and 12 weeks. Twenty six subjects participated (LOW n = 9, HIGH n = 10, ISOK n = 7). The main finding from this study is that a 12-week OKCKE resistance training programme at loads of 20 sets of 2RM, leads to an increase in manual maximal AKL. OKCKE resistance training at high loads (20 sets of 2RM) increases AKL while low load OKCKE resistance training (2 sets of 20RM) and isokinetic OKCKE resistance training at 2 sets of 20RM does not. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Aoyagi, Kiyoshi; Olson, Lawrence E.; Peterson, Randall L.; Yamauchi, Gloria K.; Ross, James C.; Norman, Thomas R.
1987-01-01
Time-averaged aerodynamic loads are estimated for each of the vane sets in the National Full-Scale Aerodynamic Complex (NFAC). The methods used to compute global and local loads are presented. Experimental inputs used to calculate these loads are based primarily on data obtained from tests conducted in the NFAC 1/10-Scale Vane-Set Test Facility and from tests conducted in the NFAC 1/50-Scale Facility. For those vane sets located directly downstream of either the 40- by 80-ft test section or the 80- by 120-ft test section, aerodynamic loads caused by the impingement of model-generated wake vortices and model-generated jet and propeller wakes are also estimated.
Estill, Janne; Egger, Matthias; Blaser, Nello; Vizcaya, Luisa Salazar; Garone, Daniela; Wood, Robin; Campbell, Jennifer; Hallett, Timothy B; Keiser, Olivia
2013-06-01
Monitoring of HIV viral load in patients on combination antiretroviral therapy (ART) is not generally available in resource-limited settings. We examined the cost-effectiveness of qualitative point-of-care viral load tests (POC-VL) in sub-Saharan Africa. Mathematical model based on longitudinal data from the Gugulethu and Khayelitsha township ART programmes in Cape Town, South Africa. Cohorts of patients on ART monitored by POC-VL, CD4 cell count or clinically were simulated. Scenario A considered the more accurate detection of treatment failure with POC-VL only, and scenario B also considered the effect on HIV transmission. Scenario C further assumed that the risk of virologic failure is halved with POC-VL due to improved adherence. We estimated the change in costs per quality-adjusted life-year gained (incremental cost-effectiveness ratios, ICERs) of POC-VL compared with CD4 and clinical monitoring. POC-VL tests with detection limits less than 1000 copies/ml increased costs due to unnecessary switches to second-line ART, without improving survival. Assuming POC-VL unit costs between US$5 and US$20 and detection limits between 1000 and 10,000 copies/ml, the ICER of POC-VL was US$4010-US$9230 compared with clinical and US$5960-US$25540 compared with CD4 cell count monitoring. In Scenario B, the corresponding ICERs were US$2450-US$5830 and US$2230-US$10380. In Scenario C, the ICER ranged between US$960 and US$2500 compared with clinical monitoring and between cost-saving and US$2460 compared with CD4 monitoring. The cost-effectiveness of POC-VL for monitoring ART is improved by a higher detection limit, by taking the reduction in new HIV infections into account and assuming that failure of first-line ART is reduced due to targeted adherence counselling.
Winstone, Nicola; Wilson, Aaron J.; Morrow, Gavin; Boggiano, Cesar; Chiuchiolo, Maria J.; Lopez, Mary; Kemelman, Marina; Ginsberg, Arielle A.; Mullen, Karl; Coleman, John W.; Wu, Chih-Da; Narpala, Sandeep; Ouellette, Ian; Dean, Hansi J.; Lin, Feng; Sardesai, Niranjan Y.; Cassamasa, Holly; McBride, Dawn; Felber, Barbara K.; Pavlakis, George N.; Schultz, Alan; Hudgens, Michael G.; King, C. Richter; Zamb, Timothy J.; Parks, Christopher L.; McDermott, Adrian B.
2011-01-01
DNA priming has previously been shown to elicit augmented immune responses when administered by electroporation (EP) or codelivered with a plasmid encoding interleukin-12 (pIL-12). We hypothesized that the efficacy of a DNA prime and recombinant adenovirus 5 boost vaccination regimen (DNA/rAd5) would be improved when incorporating these vaccination strategies into the DNA priming phase, as determined by pathogenic simian immunodeficiency virus SIVmac239 challenge outcome. The whole SIVmac239 proteome was delivered in 5 separate DNA plasmids (pDNA-SIV) by EP with or without pIL-12, followed by boosting 4 months later with corresponding rAd5-SIV vaccine vectors. Remarkably, after repeated low-dose SIVmac239 mucosal challenge, we demonstrate 2.6 and 4.4 log reductions of the median SIV peak and set point viral loads in rhesus macaques (RMs) that received pDNA-SIV by EP with pIL-12 compared to the median peak and set point viral loads in mock-immunized controls (P < 0.01). In 5 out of 6 infected RMs, strong suppression of viremia was observed, with intermittent “blips” in virus replication. In 2 RMs, we could not detect the presence of SIV RNA in tissue and lymph nodes, even after 13 viral challenges. RMs immunized without pIL-12 demonstrated a typical maximum of 1.5 log reduction in virus load. There was no significant difference in the overall magnitude of SIV-specific antibodies or CD8 T-cell responses between groups; however, pDNA delivery by EP with pIL-12 induced a greater magnitude of SIV-specific CD4 T cells that produced multiple cytokines. This vaccine strategy is relevant for existing vaccine candidates entering clinical evaluation, and this model may provide insights into control of retrovirus replication. PMID:21734035
An alternative method for centrifugal compressor loading factor modelling
NASA Astrophysics Data System (ADS)
Galerkin, Y.; Drozdov, A.; Rekstin, A.; Soldatova, K.
2017-08-01
The loading factor at design point is calculated by one or other empirical formula in classical design methods. Performance modelling as a whole is out of consideration. Test data of compressor stages demonstrates that loading factor versus flow coefficient at the impeller exit has a linear character independent of compressibility. Known Universal Modelling Method exploits this fact. Two points define the function - loading factor at design point and at zero flow rate. The proper formulae include empirical coefficients. A good modelling result is possible if the choice of coefficients is based on experience and close analogs. Earlier Y. Galerkin and K. Soldatova had proposed to define loading factor performance by the angle of its inclination to the ordinate axis and by the loading factor at zero flow rate. Simple and definite equations with four geometry parameters were proposed for loading factor performance calculated for inviscid flow. The authors of this publication have studied the test performance of thirteen stages of different types. The equations are proposed with universal empirical coefficients. The calculation error lies in the range of plus to minus 1,5%. The alternative model of a loading factor performance modelling is included in new versions of the Universal Modelling Method.
Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals
NASA Technical Reports Server (NTRS)
Ulbrich, N.; Volden, T.
2014-01-01
An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.
Euler Strut: A Mechanical Analogy for Dynamics in the Vicinity of a Critical Point
ERIC Educational Resources Information Center
Bobnar, Jaka; Susman, Katarina; Parsegian, V. Adrian; Rand, Peter R.; Cepic, Mojca; Podgornik, Rudolf
2011-01-01
An anchored elastic filament (Euler strut) under an external point load applied to its free end is a simple model for a second-order phase transition. In the static case, a load greater than the critical load causes a Euler buckling instability, leading to a change in the filament's shape. The analysis of filament dynamics with an external point…
NASA Astrophysics Data System (ADS)
Noh, Hae Young; Rajagopal, Ram; Kiremidjian, Anne S.
2012-04-01
This paper introduces a damage diagnosis algorithm for civil structures that uses a sequential change point detection method for the cases where the post-damage feature distribution is unknown a priori. This algorithm extracts features from structural vibration data using time-series analysis and then declares damage using the change point detection method. The change point detection method asymptotically minimizes detection delay for a given false alarm rate. The conventional method uses the known pre- and post-damage feature distributions to perform a sequential hypothesis test. In practice, however, the post-damage distribution is unlikely to be known a priori. Therefore, our algorithm estimates and updates this distribution as data are collected using the maximum likelihood and the Bayesian methods. We also applied an approximate method to reduce the computation load and memory requirement associated with the estimation. The algorithm is validated using multiple sets of simulated data and a set of experimental data collected from a four-story steel special moment-resisting frame. Our algorithm was able to estimate the post-damage distribution consistently and resulted in detection delays only a few seconds longer than the delays from the conventional method that assumes we know the post-damage feature distribution. We confirmed that the Bayesian method is particularly efficient in declaring damage with minimal memory requirement, but the maximum likelihood method provides an insightful heuristic approach.
NASA Technical Reports Server (NTRS)
Lim, Sang G.; Brewe, David E.; Prahl, Joseph M.
1990-01-01
The transient analysis of hydrodynamic lubrication of a point-contact is presented. A body-fitted coordinate system is introduced to transform the physical domain to a rectangular computational domain, enabling the use of the Newton-Raphson method for determining pressures and locating the cavitation boundary, where the Reynolds boundary condition is specified. In order to obtain the transient solution, an explicit Euler method is used to effect a time march. The transient dynamic load is a sinusoidal function of time with frequency, fractional loading, and mean load as parameters. Results include the variation of the minimum film thickness and phase-lag with time as functions of excitation frequency. The results are compared with the analytic solution to the transient step bearing problem with the same dynamic loading function. The similarities of the results suggest an approximate model of the point contact minimum film thickness solution.
NASA Astrophysics Data System (ADS)
Seryakov, A. V.; Konkin, A. V.
2017-11-01
The results of the numerical simulation of pulsations in the Laval-liked vapour channel of short low-temperature range heat pipes (HPs) are presented. The numerical results confirmed the experimentally obtained increase of the frequency of pulsations in the vapour channel of short HPs with increasing overheat of the porous evaporator relative to the boiling point of the working fluid. The occurrence of pressure pulsations inside the vapour channel in a short HPs is a complex phenomenon associated with the boiling beginning in the capillary-porous evaporator at high heat loads, and appearance the excess amount of vapour above it, leading to the increase in pressure P to a value at which the boiling point TB of the working fluid becomes higher than the evaporator temperature Tev. Vapour clot spreads through the vapour channel and condense, and then a rarefaction wave return from condenser in the evaporator, the boiling in which is resumed and the next cycle of the pulsations is repeated. Numerical simulation was performed using finite element method implemented in the commercial program ANSYS Multiphisics 14.5 in the two-dimensional setting of axis symmetric moist vapour flow with third kind boundary conditions.
Optimal robust control strategy of a solid oxide fuel cell system
NASA Astrophysics Data System (ADS)
Wu, Xiaojuan; Gao, Danhui
2018-01-01
Optimal control can ensure system safe operation with a high efficiency. However, only a few papers discuss optimal control strategies for solid oxide fuel cell (SOFC) systems. Moreover, the existed methods ignore the impact of parameter uncertainty on system instantaneous performance. In real SOFC systems, several parameters may vary with the variation of operation conditions and can not be identified exactly, such as load current. Therefore, a robust optimal control strategy is proposed, which involves three parts: a SOFC model with parameter uncertainty, a robust optimizer and robust controllers. During the model building process, boundaries of the uncertain parameter are extracted based on Monte Carlo algorithm. To achieve the maximum efficiency, a two-space particle swarm optimization approach is employed to obtain optimal operating points, which are used as the set points of the controllers. To ensure the SOFC safe operation, two feed-forward controllers and a higher-order robust sliding mode controller are presented to control fuel utilization ratio, air excess ratio and stack temperature afterwards. The results show the proposed optimal robust control method can maintain the SOFC system safe operation with a maximum efficiency under load and uncertainty variations.
2011-01-01
Background The Prospective Space-Time scan statistic (PST) is widely used for the evaluation of space-time clusters of point event data. Usually a window of cylindrical shape is employed, with a circular or elliptical base in the space domain. Recently, the concept of Minimum Spanning Tree (MST) was applied to specify the set of potential clusters, through the Density-Equalizing Euclidean MST (DEEMST) method, for the detection of arbitrarily shaped clusters. The original map is cartogram transformed, such that the control points are spread uniformly. That method is quite effective, but the cartogram construction is computationally expensive and complicated. Results A fast method for the detection and inference of point data set space-time disease clusters is presented, the Voronoi Based Scan (VBScan). A Voronoi diagram is built for points representing population individuals (cases and controls). The number of Voronoi cells boundaries intercepted by the line segment joining two cases points defines the Voronoi distance between those points. That distance is used to approximate the density of the heterogeneous population and build the Voronoi distance MST linking the cases. The successive removal of edges from the Voronoi distance MST generates sub-trees which are the potential space-time clusters. Finally, those clusters are evaluated through the scan statistic. Monte Carlo replications of the original data are used to evaluate the significance of the clusters. An application for dengue fever in a small Brazilian city is presented. Conclusions The ability to promptly detect space-time clusters of disease outbreaks, when the number of individuals is large, was shown to be feasible, due to the reduced computational load of VBScan. Instead of changing the map, VBScan modifies the metric used to define the distance between cases, without requiring the cartogram construction. Numerical simulations showed that VBScan has higher power of detection, sensitivity and positive predicted value than the Elliptic PST. Furthermore, as VBScan also incorporates topological information from the point neighborhood structure, in addition to the usual geometric information, it is more robust than purely geometric methods such as the elliptic scan. Those advantages were illustrated in a real setting for dengue fever space-time clusters. PMID:21513556
Lai, Y-C; Li, H-Y; Hung, C-S; Lin, M-S; Shih, S-R; Ma, W-Y; Hua, C-H; Chuang, L-M; Sung, F-C; Wei, J-N
2013-03-01
To evaluate whether homeostasis model assessment and high-sensitivity C-reactive protein improve the prediction of isolated post-load hyperglycaemia. The subjects were 1458 adults without self-reported diabetes recruited between 2006 and 2010. Isolated post-load hyperglycaemia was defined as fasting plasma glucose < 7 mmol/l and 2-h post-load plasma glucose ≥ 11.1 mmol/l. Risk scores of isolated post-load hyperglycaemia were constructed by multivariate logistic regression. An independent group (n = 154) was enrolled from 2010 to 2011 to validate the models' performance. One hundred and twenty-three subjects (8.28%) were newly diagnosed as having diabetes mellitus. Among those with undiagnosed diabetes, 64 subjects (52%) had isolated post-load hyperglycaemia. Subjects with isolated post-load hyperglycaemia were older, more centrally obese and had higher blood pressure, HbA(1c), fasting plasma glucose, triglycerides, LDL cholesterol, high-sensitivity C-reactive protein and homeostasis model assessment of insulin resistance and lower homeostasis model assessment of β-cell function than those without diabetes. The risk scores included age, gender, BMI, homeostasis model assessment, high-sensitivity C-reactive protein and HbA(1c). The full model had high sensitivity (84%) and specificity (87%) and area under the receiver operating characteristic curve (0.91), with a cut-off point of 23.81; validation in an independent data set showed 88% sensitivity, 77% specificity and an area under curve of 0.89. Over half of those with undiagnosed diabetes had isolated post-load hyperglycaemia. Homeostasis model assessment and high-sensitivity C-reactive protein are useful to identify subjects with isolated post-load hyperglycaemia, with improved performance over fasting plasma glucose or HbA(1c) alone. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.
Alternative electrical distribution system architectures for automobiles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Afridi, K.K.; Tabors, R.D.; Kassakian, J.G.
At present most automobiles use a 12 V electrical system with point-to-point wiring. The capability of this architecture in meeting the needs of future electrical loads is questionable. Furthermore, with the development of electric vehicles (EVs) there is a greater need for a better architecture. In this paper the authors outline the limitations of the conventional architecture and identify alternatives. They also present a multi-attribute trade-off methodology which compares these alternatives, and identifies a set of Pareto optimal architectures. The system attributes traded off are cost, weight, losses and probability of failure. These are calculated by a computer program thatmore » has built-in component attribute models. System attributes of a few dozen architectures are also reported and the results analyzed. 17 refs.« less
Tuning rules for robust FOPID controllers based on multi-objective optimization with FOPDT models.
Sánchez, Helem Sabina; Padula, Fabrizio; Visioli, Antonio; Vilanova, Ramon
2017-01-01
In this paper a set of optimally balanced tuning rules for fractional-order proportional-integral-derivative controllers is proposed. The control problem of minimizing at once the integrated absolute error for both the set-point and the load disturbance responses is addressed. The control problem is stated as a multi-objective optimization problem where a first-order-plus-dead-time process model subject to a robustness, maximum sensitivity based, constraint has been considered. A set of Pareto optimal solutions is obtained for different normalized dead times and then the optimal balance between the competing objectives is obtained by choosing the Nash solution among the Pareto-optimal ones. A curve fitting procedure has then been applied in order to generate suitable tuning rules. Several simulation results show the effectiveness of the proposed approach. Copyright © 2016. Published by Elsevier Ltd.
Efficient bulk-loading of gridfiles
NASA Technical Reports Server (NTRS)
Leutenegger, Scott T.; Nicol, David M.
1994-01-01
This paper considers the problem of bulk-loading large data sets for the gridfile multiattribute indexing technique. We propose a rectilinear partitioning algorithm that heuristically seeks to minimize the size of the gridfile needed to ensure no bucket overflows. Empirical studies on both synthetic data sets and on data sets drawn from computational fluid dynamics applications demonstrate that our algorithm is very efficient, and is able to handle large data sets. In addition, we present an algorithm for bulk-loading data sets too large to fit in main memory. Utilizing a sort of the entire data set it creates a gridfile without incurring any overflows.
A quantitative method for evaluating inferior glenohumeral joint stiffness using ultrasonography.
Tsai, Wen-Wei; Lee, Ming-Yih; Yeh, Wen-Lin; Cheng, Shih-Chung; Soon, Kok-Soon; Lei, Kin Fong; Lin, Wen-Yen
2013-02-01
Subluxation of the affected shoulder in post-stroke patients is associated with nerve disorders and muscle fatigue. Clinicians must be able to accurately and reliably measure inferior glenohumeral subluxation in patients to provide appropriate treatment. However, quantitative methods for evaluating the laxity and stiffness of the glenohumeral joint (GHJ) are still being developed. The aim of this study was to develop a new protocol for evaluating the laxity and stiffness of the inferior GHJ using ultrasonography under optimal testing conditions and to investigate changes in the GHJ from a commercially available humerus brace and shoulder brace. Multistage inferior displacement forces were applied to create a glide between the most cephalad point on the visible anterosuperior surface of the humeral head and coracoid process in seven healthy volunteers. GHJ stiffness was defined as the slope of the linear regression line between the glides and different testing loads. The testing conditions were defined by different test loading mechanisms (n=2), shoulder constraining conditions (n=2), and loading modes (n=4). The optimal testing condition was defined as the condition with the least residual variance of measured laxity to the calculated stiffness under different testing loads. A paired t-test was used to compare the laxity and stiffness of the inferior GHJ using different braces. No significant difference was identified between the two test loading mechanisms (t=0.218, p=0.831) and two shoulder constraining conditions (t=-0.235, p=0.818). We concluded that ultrasonographic laxity measurements performed using a pulley set loading mechanism was as reliable as direct loading. Additionally, constraining the unloaded shoulder was proposed due to the lower mean residual variance value. Moreover, pulling the elbow downward with loading on the upper arm was suggested, as pulling the elbow downward with the elbow flexed and loading on the forearm may overestimate stiffness and pain in the inferior GHJ at the loading point due to friction between the wide belt and skin. Furthermore, subjects wearing a humerus brace with a belt, which creates the effect of lifting the humerus toward the acromion, had greater GHJ stiffness compared to subjects wearing a shoulder brace without a belt to lift the humerus under the proposed testing conditions. This study provides experimental evidence that shoulder braces may reduce GHJ laxity under an external load, implying that the use of a humeral brace can prevent subluxation in post-stroke patients. The resulting optimal testing conditions for measuring the laxity and stiffness of the GHJ is to constrain the unloaded shoulder and bend the loaded arm at the elbow with loading on the upper arm using a pulley system. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
Some Remarks on Foundation Pile Testing Procedures
NASA Astrophysics Data System (ADS)
Rybak, Jarosław
2017-10-01
This work presents the review of pile capacity testing techniques. In an overview, the key points in pile designing are: determination of the appropriate computational schemes, reliable data on loads and the properties of structural materials (in particular, of the soil mass, which is marked by the greatest variability). The procedure of constructing a pile foundation should include: carrying out soil tests in the scope that ensures safe designing, selecting a piling technology that is relevant both to geotechnical conditions and expected loads, drafting a piling design together with the design of load tests, setting up a testing station for further load tests, static and/or dynamic tests of pile load capacity, preceded by supplementary soil tests when the conditions of test pile installation fail to comply with the design assumptions or when the pile length exceeds the depth of the previously investigated soil, making documentation of load capacity tests (with an additional correction of the piling design), the actual piling (ongoing analysis of pile driving logs and, if necessary, testing the piles’ integrity), drawing up the as-built documentation. Unfortunately, the design is corrected after the load test have been conducted only if the piles fail to show the designed bearing capacity. The designer is then obliged to revise the design assumptions on the basis of tests results. If the test results account for the a greater bearing capacity than necessary and it would be recommendable to limit the extent of the planned (i.e. set out in the contract) piling works, usually neither the contractor nor the designer, nor even the Construction Site Supervisor, acting for the benefit of the Investor, are willing to take on the responsibility for reducing the scope of the piling works. The necessity of conducting additional control tests before and during the implementation of the construction project is often treated by the investors as an attempt at extorting extra financial resources or at delaying the project implementation. The designer, however, has no other possibility (and often - he/she does not have required qualifications) to verify the obtained test results.
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
PynPoint code for exoplanet imaging
NASA Astrophysics Data System (ADS)
Amara, A.; Quanz, S. P.; Akeret, J.
2015-04-01
We announce the public release of PynPoint, a Python package that we have developed for analysing exoplanet data taken with the angular differential imaging observing technique. In particular, PynPoint is designed to model the point spread function of the central star and to subtract its flux contribution to reveal nearby faint companion planets. The current version of the package does this correction by using a principal component analysis method to build a basis set for modelling the point spread function of the observations. We demonstrate the performance of the package by reanalysing publicly available data on the exoplanet β Pictoris b, which consists of close to 24,000 individual image frames. We show that PynPoint is able to analyse this typical data in roughly 1.5 min on a Mac Pro, when the number of images is reduced by co-adding in sets of 5. The main computational work, the calculation of the Singular-Value-Decomposition, parallelises well as a result of a reliance on the SciPy and NumPy packages. For this calculation the peak memory load is 6 GB, which can be run comfortably on most workstations. A simpler calculation, by co-adding over 50, takes 3 s with a peak memory usage of 600 MB. This can be performed easily on a laptop. In developing the package we have modularised the code so that we will be able to extend functionality in future releases, through the inclusion of more modules, without it affecting the users application programming interface. We distribute the PynPoint package under GPLv3 licence through the central PyPI server, and the documentation is available online (http://pynpoint.ethz.ch).
Empirical comparison of heuristic load distribution in point-to-point multicomputer networks
NASA Technical Reports Server (NTRS)
Grunwald, Dirk C.; Nazief, Bobby A. A.; Reed, Daniel A.
1990-01-01
The study compared several load placement algorithms using instrumented programs and synthetic program models. Salient characteristics of these program traces (total computation time, total number of messages sent, and average message time) span two orders of magnitude. Load distribution algorithms determine the initial placement for processes, a precursor to the more general problem of load redistribution. It is found that desirable workload distribution strategies will place new processes globally, rather than locally, to spread processes rapidly, but that local information should be used to refine global placement.
NASA Astrophysics Data System (ADS)
Li, Peng; Jiang, Shengyuan; Tang, Dewei; Xu, Bo
2017-05-01
For sake of striking a balance between the need of drilling efficiency and the constrains of power budget on the moon, the penetrations per revolution of drill bit are generally limited in the range around 0.1 mm, and besides the geometric angle of the cutting blade need to be well designed. This paper introduces a simulation approach based on PFC3D (particle flow code 3 dimensions) for analyzing the cutting load feature on lunar rock simulant, which is derived from different geometric-angle blades with a small cutting depth. The mean values of the cutting force of five blades in the survey region (four on the boundary points and one on the center point) are selected as the macroscopic responses of model. The method of experimental design which includes Plackett-Burman (PB) design and central composite design (CCD) method is adopted in the matching procedure of microparameters in PFC model. Using the optimization method of enumeration, the optimum set of microparameters is acquired. Then, the experimental validation is implemented by using other twenty-five blades with different geometric angles, and the results from both simulations and laboratory tests give fair agreements. Additionally, the rock breaking process cut by different blades are quantified from simulation analysis. This research provides the theoretical support for the refinement of the rock cutting load prediction and the geometric design of cutting blade on the drill bit.
Simulation of flow and water quality of the Arroyo Colorado, Texas, 1989-99
Raines, Timothy H.; Miranda, Roger M.
2002-01-01
A model parameter set for use with the Hydrological Simulation Program—FORTRAN watershed model was developed to simulate flow and water quality for selected properties and constituents for the Arroyo Colorado from the city of Mission to the Laguna Madre, Texas. The model simulates flow, selected water-quality properties, and constituent concentrations. The model can be used to estimate a total maximum daily load for selected properties and constituents in the Arroyo Colorado. The model was calibrated and tested for flow with data measured during 1989–99 at three streamflow-gaging stations. The errors for total flow volume ranged from -0.1 to 29.0 percent, and the errors for total storm volume ranged from -15.6 to 8.4 percent. The model was calibrated and tested for water quality for seven properties and constituents with 1989–99 data. The model was calibrated sequentially for suspended sediment, water temperature, biochemical oxygen demand, dissolved oxygen, nitrate nitrogen, ammonia nitrogen, and orthophosphate. The simulated concentrations of the selected properties and constituents generally matched the measured concentrations available for the calibration and testing periods. The model was used to simulate total point- and nonpoint-source loads for selected properties and constituents for 1989–99 for urban, natural, and agricultural land-use types. About one-third to one-half of the biochemical oxygen demand and nutrient loads are from urban point and nonpoint sources, although only 13 percent of the total land use in the basin is urban.
NASA Astrophysics Data System (ADS)
Stergiopoulos, Ch.; Stavrakas, I.; Triantis, D.; Vallianatos, F.; Stonham, J.
2015-02-01
Weak electric signals termed as 'Pressure Stimulated Currents, PSC' are generated and detected while cement based materials are found under mechanical load, related to the creation of cracks and the consequent evolution of cracks' network in the bulk of the specimen. During the experiment a set of cement mortar beams of rectangular cross-section were subjected to Three-Point Bending (3PB). For each one of the specimens an abrupt mechanical load step was applied, increased from the low load level (Lo) to a high final value (Lh) , where Lh was different for each specimen and it was maintained constant for long time. The temporal behavior of the recorded PSC show that during the load increase a spike-like PSC emission was recorded and consequently a relaxation of the PSC, after reaching its final value, follows. The relaxation process of the PSC was studied using non-extensive statistical physics (NESP) based on Tsallis entropy equation. The behavior of the Tsallis q parameter was studied in relaxation PSCs in order to investigate its potential use as an index for monitoring the crack evolution process with a potential use in non-destructive laboratory testing of cement-based specimens of unknown internal damage level. The dependence of the q-parameter on the Lh (when Lh <0.8Lf), where Lf represents the 3PB strength of the specimen, shows an increase on the q value when the specimens are subjected to gradually higher bending loadings and reaches a maximum value close to 1.4 when the applied Lh becomes higher than 0.8Lf. While the applied Lh becomes higher than 0.9Lf the value of the q-parameter gradually decreases. This analysis of the experimental data manifests that the value of the entropic index q obtains a characteristic decrease while reaching the ultimate strength of the specimen, and thus could be used as a forerunner of the expected failure.
NASA Astrophysics Data System (ADS)
Mohanty, Shyama Prasad; Bhargava, Parag
2012-11-01
Nanoparticle loaded quasi solid electrolytes are important from the view point of developing electrolytes for dye sensitized solar cells (DSSCs) having long term stability. The present work shows the influence of isoelectric point of nanopowders in electrolyte on the photoelectrochemical characteristics of DSSCs. Electrolytes with nanopowders of silica, alumina and magnesia which have widely differing isoelectric points are used in the study. Adsorption of ions from the electrolyte on the nanopowder surface, characterized by zeta potential measurement, show that cations get adsorbed on silica, alumina surface while anions get adsorbed on magnesia surface. The electrochemical characteristics of nanoparticulate loaded electrolytes are examined through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). DSSCs fabricated using liquid, silica or alumina loaded electrolytes exhibit almost similar performance. But interestingly, the magnesia loaded electrolyte-based cell show lower short circuit current density (JSC) and much higher open circuit voltage (VOC), which is attributed to adsorption of anions. Such anionic adsorption prevents the dark reaction in magnesia loaded electrolyte-based cell and thus, enhances the VOC by almost 100 mV as compared to liquid electrolyte based cell. Also, higher electron life time at the titania/electrolyte interface is observed in magnesia loaded electrolyte-based cell as compared to others.
Sediment Dynamics Over a Stable Point bar of the San Pedro River, Southeastern Arizona
NASA Astrophysics Data System (ADS)
Hamblen, J. M.; Conklin, M. H.
2002-12-01
Streams of the Southwest receive enormous inputs of sediment during storm events in the monsoon season due to the high intensity rainfall and large percentages of exposed soil in the semi-arid landscape. In the Upper San Pedro River, with a watershed area of approximately 3600 square kilometers, particle size ranges from clays to boulders with large fractions of sand and gravel. This study focuses on the mechanics of scour and fill on a stable point bar. An innovative technique using seven co-located scour chains and liquid-filled, load-cell scour sensors characterized sediment dynamics over the point bar during the monsoon season of July to September 2002. The sensors were set in two transects to document sediment dynamics near the head and toe of the bar. Scour sensors record area-averaged sediment depths while scour chains measure scour and fill at a point. The average area covered by each scour sensor is 11.1 square meters. Because scour sensors have never been used in a system similar to the San Pedro, one goal of the study was to test their ability to detect changes in sediment load with time in order to determine the extent of scour and fill during monsoonal storms. Because of the predominantly unconsolidated nature of the substrate it was hypothesized that dune bedforms would develop in events less than the 1-year flood. The weak 2002 monsoon season produced only two storms that completely inundated the point bar, both less than the 1-year flood event. The first event, 34 cms, produced net deposition in areas where Johnson grass had been present and was now buried. The scour sensor at the lowest elevation, in a depression which serves as a secondary channel during storm events, recorded scour during the rising limb of the hydrograph followed by pulses we interpret to be the passage of dunes. The second event, although smaller at 28 cms, resulted from rain more than 50 km upstream and had a much longer peak and a slowly declining falling limb. During the second flood, several areas with buried vegetation were scoured back to their original bed elevations. Pulses of sediment passed over the sensor in the secondary channel and the sensor in the vegetated zone. Scour sensor measurements agree with data from scour chains (error +/- 3 cm) and surveys (error +/- 0.6 cm) performed before and after the two storm events, within the range of error of each method. All load sensor data were recorded at five minute intervals. Use of a smaller interval could give more details about the shapes of sediment waves and aid in bedform determination. Results suggest that dune migration is the dominant mechanism for scour and backfill in the point bar setting. Scour sensors, when coupled with surveying and/or scour chains, are a tremendous addition to the geomorphologist's toolbox, allowing unattended real-time measurements of sediment depth with time.
Kailer, Andreas; Stephan, Marc
2016-10-01
The fracture toughness determination of fine-grained zirconia ceramics using the chevron notched beam method (CNB) was investigated to assess the feasibility of this method for quality assurance and material characterization. CNB tests were performed using four different yttria-stabilized zirconia ceramics under various testing modes and conditions, including displacement-controlled and load-rate-controlled four point bending to assess the influence of slow crack growth and identify most suitable test parameters. For comparison, tests using single-edge V-notch beams (SEVNB) were conducted. It was observed that the CNB method yields well-reproducible results. However, slow crack growth effects significantly affect the measured KIC values, especially when slow loading rates are used. To minimize the effect of slow crack growth, the application of high loading rates is recommended. Despite a certain effort needed for setting up a sample preparation routine, the CNB method is considered to be very useful for measuring and controlling the fracture toughness of zirconia ceramics. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Curvature methods of damage detection using digital image correlation
NASA Astrophysics Data System (ADS)
Helfrick, Mark N.; Niezrecki, Christopher; Avitabile, Peter
2009-03-01
Analytical models have shown that local damage in a structure can be detected by studying changes in the curvature of the structure's displaced shape while under an applied load. In order for damage to be detected, located, and quantified using curvature methods, a spatially dense set of measurement points is required on the structure of interest and the change in curvature must be measurable. Experimental testing done to validate the theory is often plagued by sparse data sets and experimental noise. Furthermore, the type of load, the location and severity of the damage, and the mechanical properties (material and geometry) of the structure have a significant effect on how much the curvature will change. Within this paper, three-dimensional (3D) Digital Image Correlation (DIC) as one possible method for detecting damage through curvature methods is investigated. 3D DIC is a non-contacting full-field measurement technique which uses a stereo pair of digital cameras to capture surface shape. This approach allows for an extremely dense data set across the entire visible surface of an object. A test is performed to validate the approach on an aluminum cantilever beam. A dynamic load is applied to the beam which allows for measurements to be made of the beam's response at each of its first three resonant frequencies, corresponding to the first three bending modes of the structure. DIC measurements are used with damage detection algorithms to predict damage location with varying levels of damage inflicted in the form of a crack with a prescribed depth. The testing demonstrated that this technique will likely only work with structures where a large displaced shape is easily achieved and in cases where the damage is relatively severe. Practical applications and limitations of the technique are discussed.
NASA Astrophysics Data System (ADS)
Zhang, S.; Tang, L.
2007-05-01
Panjiakou Reservoir is an important drinking water resource in Haihe River Basin, Hebei Province, People's Republic of China. The upstream watershed area is about 35,000 square kilometers. Recently, the water pollution in the reservoir is becoming more serious owing to the non-point pollution as well as point source pollution on the upstream watershed. To effectively manage the reservoir and watershed and develop a plan to reduce pollutant loads, the loading of non-point and point pollution and their distribution on the upstream watershed must be understood fully. The SWAT model is used to simulate the production and transportation of the non-point source pollutants in the upstream watershed of the Panjiakou Reservoir. The loadings of non-point source pollutants are calculated for different hydrologic years and the spatial and temporal characteristics of non-point source pollution are studied. The stream network and topographic characteristics of the stream network and sub-basins are all derived from the DEM by ArcGIS software. The soil and land use data are reclassified and the soil physical properties database file is created for the model. The SWAT model was calibrated with observed data of several hydrologic monitoring stations in the study area. The results of the calibration show that the model performs fairly well. Then the calibrated model was used to calculate the loadings of non-point source pollutants for a wet year, a normal year and a dry year respectively. The time and space distribution of flow, sediment and non-point source pollution were analyzed depending on the simulated results. The comparison of different hydrologic years on calculation results is dramatic. The loading of non-point source pollution in the wet year is relatively larger but smaller in the dry year since the non-point source pollutants are mainly transported through the runoff. The pollution loading within a year is mainly produced in the flood season. Because SWAT is a distributed model, it is possible to view model output as it varies across the basin, so the critical areas and reaches can be found in the study area. According to the simulation results, it is found that different land uses can yield different results and fertilization in rainy season has an important impact on the non- point source pollution. The limitations of the SWAT model are also discussed and the measures of the control and prevention of non- point source pollution for Panjiakou Reservoir are presented according to the analysis of model calculation results.
Kusumoto, Yasuaki; Nitta, Osamu; Takaki, Kenji
2016-10-01
In the present study, we aimed to determine whether similarly loaded sit-to-stand exercises at different speeds improve the physiological cost of walking in children with spastic diplegia. This design was a single-blind randomized clinical trial. Sixteen children with cerebral palsy (CP), aged 12-18 years, with a diagnosis of spastic diplegia, were randomly allocated to a slow loaded sit-to-stand exercise group (n=8) and a self-paced loaded sit-to-stand exercise group (n=8). Loaded sit-to-stand exercise was conducted at home for 15min, 4 sets per day, 3-4days per week, for 6 weeks. The patients were evaluated immediately before the intervention and after the training. Lower limb muscle strength using a hand-held dynamometer, selective voluntary motor control using SCALE, 6-min walk distance (6MWD), and Physiological Cost Index (PCI) were measured. The 6MWD showed a significant difference before and after intervention. PCI showed a significant difference between the two groups and the two time points. 6MWD and the PCI improved after intervention in the slow sit-to-stand exercise group. Compared to loaded sit-to-stand exercise at a regular speed, slow low-loaded sit-to-stand exercise improved the 6MWD and PCI in children with CP, suggesting that this decrease in speed during exercise improves the physiological cost of walking in these children. Copyright © 2016 Elsevier Ltd. All rights reserved.
Determination of stresses in RC eccentrically compressed members using optimization methods
NASA Astrophysics Data System (ADS)
Lechman, Marek; Stachurski, Andrzej
2018-01-01
The paper presents an optimization method for determining the strains and stresses in reinforced concrete (RC) members subjected to the eccentric compression. The governing equations for strains in the rectangular cross-sections are derived by integrating the equilibrium equations of cross-sections, taking account of the effect of concrete softening in plastic range and the mean compressive strength of concrete. The stress-strain relationship for concrete in compression for short term uniaxial loading is assumed according to Eurocode 2 for nonlinear analysis. For reinforcing steel linear-elastic model with hardening in plastic range is applied. The task consists in the solving the set of the derived equations s.t. box constraints. The resulting problem was solved by means of fmincon function implemented from the Matlab's Optimization Toolbox. Numerical experiments have shown the existence of many points verifying the equations with a very good accuracy. Therefore, some operations from the global optimization were included: start of fmincon from many points and clusterization. The model is verified on the set of data encountered in the engineering practice.
NASA Astrophysics Data System (ADS)
Hamlin, Q. F.; Kendall, A. D.; Martin, S. L.; Whitenack, H. D.; Roush, J. A.; Hannah, B. A.; Hyndman, D. W.
2017-12-01
Excessive loading of nitrogen and phosphorous to the landscape has caused biologically and economically damaging eutrophication and harmful algal blooms in the Great Lakes Basin (GLB) and across the world. We mapped source-specific loads of nitrogen and phosphorous to the landscape using broadly available data across the GLB. SENSMap (Spatially Explicit Nutrient Source Map) is a 30m resolution snapshot of nutrient loads ca. 2010. We use these maps to study variable nutrient loading and provide this information to watershed managers through NOAA's GLB Tipping Points Planner. SENSMap individually maps nutrient point sources and six non-point sources: 1) atmospheric deposition, 2) septic tanks, 3) non-agricultural chemical fertilizer, 4) agricultural chemical fertilizer, 5) manure, and 6) nitrogen fixation from legumes. To model source-specific loads at high resolution, SENSMap synthesizes a wide range of remotely sensed, surveyed, and tabular data. Using these spatially explicit nutrient loading maps, we can better calibrate local land use-based water quality models and provide insight to watershed managers on how to focus nutrient reduction strategies. Here we examine differences in dominant nutrient sources across the GLB, and how those sources vary by land use. SENSMap's high resolution, source-specific approach offers a different lens to understand nutrient loading than traditional semi-distributed or land use based models.
NASA Astrophysics Data System (ADS)
Kang, Jidong; Gianetto, James A.; Tyson, William R.
2018-03-01
Fracture toughness measurement is an integral part of structural integrity assessment of pipelines. Traditionally, a single-edge-notched bend (SE(B)) specimen with a deep crack is recommended in many existing pipeline structural integrity assessment procedures. Such a test provides high constraint and therefore conservative fracture toughness results. However, for girth welds in service, defects are usually subjected to primarily tensile loading where the constraint is usually much lower than in the three-point bend case. Moreover, there is increasing use of strain-based design of pipelines that allows applied strains above yield. Low-constraint toughness tests represent more realistic loading conditions for girth weld defects, and the corresponding increased toughness can minimize unnecessary conservatism in assessments. In this review, we present recent developments in low-constraint fracture toughness testing, specifically using single-edgenotched tension specimens, SENT or SE(T). We focus our review on the test procedure development and automation, round-robin test results and some common concerns such as the effect of crack tip, crack size monitoring techniques, and testing at low temperatures. Examples are also given of the integration of fracture toughness data from SE(T) tests into structural integrity assessment.
LOD-based clustering techniques for efficient large-scale terrain storage and visualization
NASA Astrophysics Data System (ADS)
Bao, Xiaohong; Pajarola, Renato
2003-05-01
Large multi-resolution terrain data sets are usually stored out-of-core. To visualize terrain data at interactive frame rates, the data needs to be organized on disk, loaded into main memory part by part, then rendered efficiently. Many main-memory algorithms have been proposed for efficient vertex selection and mesh construction. Organization of terrain data on disk is quite difficult because the error, the triangulation dependency and the spatial location of each vertex all need to be considered. Previous terrain clustering algorithms did not consider the per-vertex approximation error of individual terrain data sets. Therefore, the vertex sequences on disk are exactly the same for any terrain. In this paper, we propose a novel clustering algorithm which introduces the level-of-detail (LOD) information to terrain data organization to map multi-resolution terrain data to external memory. In our approach the LOD parameters of the terrain elevation points are reflected during clustering. The experiments show that dynamic loading and paging of terrain data at varying LOD is very efficient and minimizes page faults. Additionally, the preprocessing of this algorithm is very fast and works from out-of-core.
Boeing Smart Rotor Full-scale Wind Tunnel Test Data Report
NASA Technical Reports Server (NTRS)
Kottapalli, Sesi; Hagerty, Brandon; Salazar, Denise
2016-01-01
A full-scale helicopter smart material actuated rotor technology (SMART) rotor test was conducted in the USAF National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel at NASA Ames. The SMART rotor system is a five-bladed MD 902 bearingless rotor with active trailing-edge flaps. The flaps are actuated using piezoelectric actuators. Rotor performance, structural loads, and acoustic data were obtained over a wide range of rotor shaft angles of attack, thrust, and airspeeds. The primary test objective was to acquire unique validation data for the high-performance computing analyses developed under the Defense Advanced Research Project Agency (DARPA) Helicopter Quieting Program (HQP). Other research objectives included quantifying the ability of the on-blade flaps to achieve vibration reduction, rotor smoothing, and performance improvements. This data set of rotor performance and structural loads can be used for analytical and experimental comparison studies with other full-scale rotor systems and for analytical validation of computer simulation models. The purpose of this final data report is to document a comprehensive, highquality data set that includes only data points where the flap was actively controlled and each of the five flaps behaved in a similar manner.
Compliance measurements of chevron notched four point bend specimen
NASA Technical Reports Server (NTRS)
Calomino, Anthony; Bubsey, Raymond; Ghosn, Louis J.
1994-01-01
The experimental stress intensity factors for various chevron notched four point bend specimens are presented. The experimental compliance is verified using the analytical solution for a straight through crack four point bend specimen and the boundary integral equation method for one chevron geometry. Excellent agreement is obtained between the experimental and analytical results. In this report, stress intensity factors, loading displacements and crack mouth opening displacements are reported for different crack lengths and different chevron geometries, under four point bend loading condition.
NASA Astrophysics Data System (ADS)
Kwan, Matthew P.
This work demonstrates that inserting nanomolecular layers (NMLs) can profoundly change and/or lead to novel electronic and mechanical properties of metal-ceramic interfaces. The first set of results demonstrate that organophosphonate NMLs up to 1.8 nm thick can alter metal work functions by +/- 0.6 eV. This work function change is a strong function of the NML terminal groups (methyl, mercaptan, carboxylic acid, or phosphonic acid), morphology (up right, lying down, or mixed orientation), and the nature of the bonding (covalent, polar, or Van der Waals) between NML and the adjacent layers. Additionally, while NML-ceramic bond type and strength can influence and counteract the effect of NML morphology, the metal-NML bond appears to be independent of the morphology of the NML underlayer. The second set of results demonstrate that inserting an organosilane NML at a metal-ceramic interface can lead to multifold fracture toughening under both static (stress corrosion) and cyclic loads (fatigue) tested in four-point bend. Nanolayer-induced interface strengthening during static loading activates metal plasticity above the metal yield strength, leading to two-fold fracture toughening. Metal plasticity-induced toughening increases as temperature is increased up to 85 °C due to decreasing yield stress. In the fatigue fracture tests I report for the first time a loading-frequency-dependent tripling in fracture toughening in the 75-300 Hz range upon inserting a mercapto-silane NML at the weakest interface of a ceramic-polymer-metal-ceramic stack. This unusual behavior arises from the NML strengthened interface enabling load transfer to- and plasticity in the polymer layer, while the fatigue toughening magnitude and frequency range are determined by polymer rheology.
Effects of taper and space settings of telescopic Ce-TZP/A crowns on retentive force and settling.
Nakagawa, Shusuke; Torii, Katsunori; Tanaka, Masahiro
2017-03-31
The aim of this study was to investigate the effect of the taper and space setting of using Ce-TZP/A on retentive force and secondary crown settling. The taper were 2°, 4°, and 6°, and the space settings were 0 and 10 μm. The applied loads were 50 and 100 N. The taper had a significant effect on retentive force and settling at both loads (p<0.05). The space settings did not have a significant effect on retentive force or settling at either load (p<0.05). The taper of the telescopic crowns and the load affected the retentive force and the settling.
Strain Gage Loads Calibration Testing of the Active Aeroelastic Wing F/A-18 Aircraft
NASA Technical Reports Server (NTRS)
Lokos, William A.; Olney, Candida D.; Chen, Tony; Crawford, Natalie D.; Stauf, Rick; Reichenbach, Eric Y.; Bessette, Denis (Technical Monitor)
2002-01-01
This report describes strain-gage calibration loading through the application of known loads of the Active Aeroelastic Wing F/A-18 airplane. The primary goal of this test is to produce a database suitable for deriving load equations for left and right wing root and fold shear; bending moment; torque; and all eight wing control-surface hinge moments. A secondary goal is to produce a database of wing deflections measured by string potentiometers and the onboard flight deflection measurement system. Another goal is to produce strain-gage data through both the laboratory data acquisition system and the onboard aircraft data system as a check of the aircraft system. Thirty-two hydraulic jacks have applied loads through whiffletrees to 104 tension-compression load pads bonded to the lower wing surfaces. The load pads covered approximately 60 percent of the lower wing surface. A series of 72 load cases has been performed, including single-point, double-point, and distributed load cases. Applied loads have reached 70 percent of the flight limit load. Maximum wingtip deflection has reached nearly 16 in.
High load operation in a homogeneous charge compression ignition engine
Duffy, Kevin P [Metamora, IL; Kieser, Andrew J [Morton, IL; Liechty, Michael P [Chillicothe, IL; Hardy, William L [Peoria, IL; Rodman, Anthony [Chillicothe, IL; Hergart, Carl-Anders [Peoria, IL
2008-12-23
A homogeneous charge compression ignition engine is set up by first identifying combinations of compression ratio and exhaust gas percentages for each speed and load across the engines operating range. These identified ratios and exhaust gas percentages can then be converted into geometric compression ratio controller settings and exhaust gas recirculation rate controller settings that are mapped against speed and load, and made available to the electronic
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habib, Hany F; El Hariri, Mohamad; Elsayed, Ahmed
Microgrids’ adaptive protection techniques rely on communication signals from the point of common coupling to ad- just the corresponding relays’ settings for either grid-connected or islanded modes of operation. However, during communication out- ages or in the event of a cyberattack, relays settings are not changed. Thus adaptive protection schemes are rendered unsuc- cessful. Due to their fast response, supercapacitors, which are pre- sent in the microgrid to feed pulse loads, could also be utilized to enhance the resiliency of adaptive protection schemes to communi- cation outages. Proper sizing of the supercapacitors is therefore im- portant in order to maintainmore » a stable system operation and also reg- ulate the protection scheme’s cost. This paper presents a two-level optimization scheme for minimizing the supercapacitor size along with optimizing its controllers’ parameters. The latter will lead to a reduction of the supercapacitor fault current contribution and an increase in that of other AC resources in the microgrid in the ex- treme case of having a fault occurring simultaneously with a pulse load. It was also shown that the size of the supercapacitor can be reduced if the pulse load is temporary disconnected during the transient fault period. Simulations showed that the resulting super- capacitor size and the optimized controller parameters from the proposed two-level optimization scheme were feeding enough fault currents for different types of faults and minimizing the cost of the protection scheme.« less
Ngo, Hoan T; Gandra, Naveen; Fales, Andrew M; Taylor, Steve M; Vo-Dinh, Tuan
2016-07-15
One of the major obstacles to implement nucleic acid-based molecular diagnostics at the point-of-care (POC) and in resource-limited settings is the lack of sensitive and practical DNA detection methods that can be seamlessly integrated into portable platforms. Herein we present a sensitive yet simple DNA detection method using a surface-enhanced Raman scattering (SERS) nanoplatform: the ultrabright SERS nanorattle. The method, referred to as the nanorattle-based method, involves sandwich hybridization of magnetic beads that are loaded with capture probes, target sequences, and ultrabright SERS nanorattles that are loaded with reporter probes. Upon hybridization, a magnet was applied to concentrate the hybridization sandwiches at a detection spot for SERS measurements. The ultrabright SERS nanorattles, composed of a core and a shell with resonance Raman reporters loaded in the gap space between the core and the shell, serve as SERS tags for signal detection. Using this method, a specific DNA sequence of the malaria parasite Plasmodium falciparum could be detected with a detection limit of approximately 100 attomoles. Single nucleotide polymorphism (SNP) discrimination of wild type malaria DNA and mutant malaria DNA, which confers resistance to artemisinin drugs, was also demonstrated. These test models demonstrate the molecular diagnostic potential of the nanorattle-based method to both detect and genotype infectious pathogens. Furthermore, the method's simplicity makes it a suitable candidate for integration into portable platforms for POC and in resource-limited settings applications. Copyright © 2016. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Higuita Cano, Mauricio; Mousli, Mohamed Islam Aniss; Kelouwani, Sousso; Agbossou, Kodjo; Hammoudi, Mhamed; Dubé, Yves
2017-03-01
This work investigates the design and validation of a fuel cell management system (FCMS) which can perform when the fuel cell is at water freezing temperature. This FCMS is based on a new tracking technique with intelligent prediction, which combined the Maximum Efficiency Point Tracking with variable perturbation-current step and the fuzzy logic technique (MEPT-FL). Unlike conventional fuel cell control systems, our proposed FCMS considers the cold-weather conditions, the reduction of fuel cell set-point oscillations. In addition, the FCMS is built to respond quickly and effectively to the variations of electric load. A temperature controller stage is designed in conjunction with the MEPT-FL in order to operate the FC at low-temperature values whilst tracking at the same time the maximum efficiency point. The simulation results have as well experimental validation suggest that propose approach is effective and can achieve an average efficiency improvement up to 8%. The MEPT-FL is validated using a Proton Exchange Membrane Fuel Cell (PEMFC) of 500 W.
NASA Astrophysics Data System (ADS)
Jean-Jumeau, Rene
1993-03-01
Voltage collapse (VC) is generally caused by either of two types of system disturbances: load variations and contingencies. In this thesis, we study VC resulting from load variations. This is termed static voltage collapse. This thesis deals with this type of voltage collapse in electrical power systems by using a stationary bifurcations viewpoint by associating it with the occurrence of saddle node bifurcations (SNB) in the system. Approximate models are generically used in most VC analyses. We consider the validity of these models for the study of SNB and, thus, of voltage collapse. We justify the use of saddle node bifurcation as a model for VC in power systems. In particular, we prove that this leads to definition of a model and--since load demand is used as a parameter for that model--of a mode of parameterization of that model in order to represent actual power demand variations within the power system network. Ill-conditioning of the set of nonlinear equations defining a dynamical system is a generic occurence near the SNB point. We suggest a reparameterization of the set of nonlinear equations which allows to avoid this problem. A new indicator for the proximity of voltage collapse, the voltage collapse index (VCI), is developed. A new (n + 1)-dimensional set of characteristic equations for the computation of the exact SNB point, replacing the standard (2n + 1)-dimensional one is presented for general parameter -dependent nonlinear dynamical systems. These results are then applied to electric power systems for the analysis and prediction of voltage collapse. The new methods offer the potential of faster computation and greater flexibility. For reasons of theoretical development and clarity, the preceding methodologies are developed under the assumption of the absence of constraints on the system parameters and states, and the full differentiability of the functions defining the power system model. In the latter part of this thesis, we relax these assumptions in order to develop a framework and new formulation for application of the tools previously developed for the analysis and prediction of voltage collapse in practical power system models which include numerous constraints and discontinuities. Illustrations and numerical simulations throughout the thesis support our results.
Lopes, Charles Ricardo; Aoki, Marcelo Saldanha; Crisp, Alex Harley; de Mattos, Renê Scarpari; Lins, Miguel Alves; da Mota, Gustavo Ribeiro; Schoenfeld, Brad Jon; Marchetti, Paulo Henrique
2017-01-01
Abstract The purpose of this study was to evaluate the impact of moderate-load (10 RM) and low-load (20 RM) resistance training schemes on maximal strength and body composition. Sixteen resistance-trained men were randomly assigned to 1 of 2 groups: a moderate-load group (n = 8) or a low-load group (n = 8). The resistance training schemes consisted of 8 exercises performed 4 times per week for 6 weeks. In order to equate the number of repetitions performed by each group, the moderate load group performed 6 sets of 10 RM, while the low load group performed 3 sets of 20 RM. Between-group differences were evaluated using a 2-way ANOVA and independent t-tests. There was no difference in the weekly total load lifted (sets × reps × kg) between the 2 groups. Both groups equally improved maximal strength and measures of body composition after 6 weeks of resistance training, with no significant between-group differences detected. In conclusion, both moderate-load and low-load resistance training schemes, similar for the total load lifted, induced a similar improvement in maximal strength and body composition in resistance-trained men. PMID:28828088
LPV control for the full region operation of a wind turbine integrated with synchronous generator.
Cao, Guoyan; Grigoriadis, Karolos M; Nyanteh, Yaw D
2015-01-01
Wind turbine conversion systems require feedback control to achieve reliable wind turbine operation and stable current supply. A robust linear parameter varying (LPV) controller is proposed to reduce the structural loads and improve the power extraction of a horizontal axis wind turbine operating in both the partial load and the full load regions. The LPV model is derived from the wind turbine state space models extracted by FAST (fatigue, aerodynamics, structural, and turbulence) code linearization at different operating points. In order to assure a smooth transition between the two regions, appropriate frequency-dependent varying scaling parametric weighting functions are designed in the LPV control structure. The solution of a set of linear matrix inequalities (LMIs) leads to the LPV controller. A synchronous generator model is connected with the closed LPV control loop for examining the electrical subsystem performance obtained by an inner speed control loop. Simulation results of a 1.5 MW horizontal axis wind turbine model on the FAST platform illustrates the benefit of the LPV control and demonstrates the advantages of this proposed LPV controller, when compared with a traditional gain scheduling PI control and prior LPV control configurations. Enhanced structural load mitigation, improved power extraction, and good current performance were obtained from the proposed LPV control.
EPA Office of Water (OW): Impaired Waters with TMDLs NHDPlus Indexed Dataset
The Total Maximum Daily Load (TMDL) Tracking System contains information on waters that are Not Supporting their designated uses. These waters are listed by the state as impaired under Section 303(d) of the Clean Water Act. The status of TMDLs are also tracked. TMDLs are pollution control measures that reduce the discharge of pollutants into impaired waters. A TMDL or Total Maximum Daily Load is a calculation of the maximum amount of a pollutant that a waterbody can receive and still meet water quality standards, and an allocation of that amount to the pollutant's sources. What is a total maximum daily load (TMDL)? Water quality standards are set by States, Territories, and Tribes. They identify the uses for each waterbody, for example, drinking water supply, contact recreation (swimming), and aquatic life support (fishing), and the scientific criteria to support that use. A TMDL is the sum of the allowable loads of a single pollutant from all contributing point and nonpoint sources. The calculation must include a margin of safety to ensure that the waterbody can be used for the purposes the state has designated. The calculation must also account for seasonal variation in water quality. The Clean Water Act, section 303, establishes the water quality standards and TMDL programs.
LPV Control for the Full Region Operation of a Wind Turbine Integrated with Synchronous Generator
Grigoriadis, Karolos M.; Nyanteh, Yaw D.
2015-01-01
Wind turbine conversion systems require feedback control to achieve reliable wind turbine operation and stable current supply. A robust linear parameter varying (LPV) controller is proposed to reduce the structural loads and improve the power extraction of a horizontal axis wind turbine operating in both the partial load and the full load regions. The LPV model is derived from the wind turbine state space models extracted by FAST (fatigue, aerodynamics, structural, and turbulence) code linearization at different operating points. In order to assure a smooth transition between the two regions, appropriate frequency-dependent varying scaling parametric weighting functions are designed in the LPV control structure. The solution of a set of linear matrix inequalities (LMIs) leads to the LPV controller. A synchronous generator model is connected with the closed LPV control loop for examining the electrical subsystem performance obtained by an inner speed control loop. Simulation results of a 1.5 MW horizontal axis wind turbine model on the FAST platform illustrates the benefit of the LPV control and demonstrates the advantages of this proposed LPV controller, when compared with a traditional gain scheduling PI control and prior LPV control configurations. Enhanced structural load mitigation, improved power extraction, and good current performance were obtained from the proposed LPV control. PMID:25884036
Control of the low-load region in partially premixed combustion
NASA Astrophysics Data System (ADS)
Ingesson, Gabriel; Yin, Lianhao; Johansson, Rolf; Tunestal, Per
2016-09-01
Partially premixed combustion (PPC) is a low temperature, direct-injection combustion concept that has shown to give promising emission levels and efficiencies over a wide operating range. In this concept, high EGR ratios, high octane-number fuels and early injection timings are used to slow down the auto-ignition reactions and to enhance the fuel and are mixing before the start of combustion. A drawback with this concept is the combustion stability in the low-load region where a high octane-number fuel might cause misfire and low combustion efficiency. This paper investigates the problem of low-load PPC controller design for increased engine efficiency. First, low-load PPC data, obtained from a multi-cylinder heavy- duty engine is presented. The data shows that combustion efficiency could be increased by using a pilot injection and that there is a non-linearity in the relation between injection and combustion timing. Furthermore, intake conditions should be set in order to avoid operating points with unfavourable global equivalence ratio and in-cylinder temperature combinations. Model predictive control simulations were used together with a calibrated engine model to find a gas-system controller that fulfilled this task. The findings are then summarized in a suggested engine controller design. Finally, an experimental performance evaluation of the suggested controller is presented.
Nowak, Dennis A; Hermsdörfer, Joachim; Marquardt, Christian; Topka, Helge
2003-03-01
Anticipatory grip force adjustments to movement-induced load fluctuations of a hand-held object suggest that motion planning is based on an internal forward model of both the external object properties and the dynamics of the own motor apparatus. However, the central nervous system also refers to real time sensory feedback from the grasping digits in order to achieve a highly economical coupling between grip force and the actual loading requirements. We analyzed grip force control during vertical point-to-point arm movements with a hand-held instrumented object in 9 patients with moderately impaired tactile sensibility of the grasping digits due to chronic median nerve compression (n = 3), axonal (n = 3) and demyelinating sensory polyneuropathy (n = 3) in comparison to 9 healthy age- and sex-matched control subjects. Point-to-point arm movements started and ended with the object being held stationary at rest. Load force changes arose from inertial loads related to the movement. A maximum of load force occurred early in upward and near the end of downward movements. Compared to healthy controls, patients with impaired manual sensibility generated similar static grip forces during stationary holding of the object and similar force ratios between maximum grip and load force. These findings reflect effective grip force scaling in relation to the movement-induced loads despite reduced afferent feedback from the grasping digits. For both groups the maxima of grip and load force coincided very closely in time, indicating that the temporal regulation of the grip force profile with the load profile was processed with a similar high precision. In addition, linear regression analyses between grip and load forces during movement-related load increase and load decrease phases revealed a similar precise temporo-spatial coupling between grip and load forces for patients and controls. Our results suggest that the precise and anticipatory adjustment of the grip force profile to the load force profile arising from voluntary arm movements with a hand-held object is centrally mediated and less under sensory feedback control. As suggested by previous investigations, the efficient scaling of the grip force magnitude in relation to the movement-induced loads may be intact when deficits of tactile sensibility from the grasping fingers are moderate.
Electric reaction arising in bone subjected to mechanical loadings
NASA Astrophysics Data System (ADS)
Murasawa, Go; Cho, Hideo; Ogawa, Kazuma
2006-03-01
The aim of present study is the investigation of the electric reaction arising in bone subjected to mechanical loadings. Firstly, specimen was fabricated from femur of cow, and ultrasonic propagation in bone was measured by ultrasonic technique. Secondary, 4-point bending test was conducted up to fracture, and electric reaction arising in bone was measured during loading. Thirdly, cyclic 4-point bending test was conducted to investigate the effect of applied displacement speed on electric reaction.
Sewell, Justin L; Boscardin, Christy K; Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S
2017-11-01
Cognitive load theory, focusing on limits of the working memory, is relevant to medical education; however, factors associated with cognitive load during procedural skills training are not well characterized. The authors sought to determine how features of learners, patients/tasks, settings, and supervisors were associated with three types of cognitive load among learners performing a specific procedure, colonoscopy, to identify implications for procedural teaching. Data were collected through an electronically administered survey sent to 1,061 U.S. gastroenterology fellows during the 2014-2015 academic year; 477 (45.0%) participated. Participants completed the survey immediately following a colonoscopy. Using multivariable linear regression analyses, the authors identified sets of features associated with intrinsic, extraneous, and germane loads. Features associated with intrinsic load included learners (prior experience and year in training negatively associated, fatigue positively associated) and patient/tasks (procedural complexity positively associated, better patient tolerance negatively associated). Features associated with extraneous load included learners (fatigue positively associated), setting (queue order positively associated), and supervisors (supervisor engagement and confidence negatively associated). Only one feature, supervisor engagement, was (positively) associated with germane load. These data support practical recommendations for teaching procedural skills through the lens of cognitive load theory. To optimize intrinsic load, level of experience and competence of learners should be balanced with procedural complexity; part-task approaches and scaffolding may be beneficial. To reduce extraneous load, teachers should remain engaged, and factors within the procedural setting that may interfere with learning should be minimized. To optimize germane load, teachers should remain engaged.
NASA Astrophysics Data System (ADS)
Hashimoto, Hiroyuki; Takaguchi, Yusuke; Nakamura, Shizuka
Instability of calculation process and increase of calculation time caused by increasing size of continuous optimization problem remain the major issues to be solved to apply the technique to practical industrial systems. This paper proposes an enhanced quadratic programming algorithm based on interior point method mainly for improvement of calculation stability. The proposed method has dynamic estimation mechanism of active constraints on variables, which fixes the variables getting closer to the upper/lower limit on them and afterwards releases the fixed ones as needed during the optimization process. It is considered as algorithm-level integration of the solution strategy of active-set method into the interior point method framework. We describe some numerical results on commonly-used bench-mark problems called “CUTEr” to show the effectiveness of the proposed method. Furthermore, the test results on large-sized ELD problem (Economic Load Dispatching problems in electric power supply scheduling) are also described as a practical industrial application.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bezler, P.; Hartzman, M.; Reich, M.
1980-08-01
A set of benchmark problems and solutions have been developed for verifying the adequacy of computer programs used for dynamic analysis and design of nuclear piping systems by the Response Spectrum Method. The problems range from simple to complex configurations which are assumed to experience linear elastic behavior. The dynamic loading is represented by uniform support motion, assumed to be induced by seismic excitation in three spatial directions. The solutions consist of frequencies, participation factors, nodal displacement components and internal force and moment components. Solutions to associated anchor point motion static problems are not included.
Tabulation of data from the tip aerodynamics and acoustics test
NASA Technical Reports Server (NTRS)
Cross, Jeffrey L.; Tu, Wilson
1990-01-01
In a continuing effort to understand helicopter rotor tip aerodynamics and acoustics, researchers at Ames Research Center conducted a flight test. The test was performed using the NASA White Cobra and a set of highly instrumented blades. Tabular and graphic summaries of two data subsets from the Tip Aerodynamics and Acoustics Test are given. The data presented are for airloads, blade structural loads, blade vibrations, with summary tables of the aircraft states for each test point. The tabular data consist of the first 15 harmonics only, whereas the plots contain the entire measured frequency content.
Assessment of the Uniqueness of Wind Tunnel Strain-Gage Balance Load Predictions
NASA Technical Reports Server (NTRS)
Ulbrich, N.
2016-01-01
A new test was developed to assess the uniqueness of wind tunnel strain-gage balance load predictions that are obtained from regression models of calibration data. The test helps balance users to gain confidence in load predictions of non-traditional balance designs. It also makes it possible to better evaluate load predictions of traditional balances that are not used as originally intended. The test works for both the Iterative and Non-Iterative Methods that are used in the aerospace testing community for the prediction of balance loads. It is based on the hypothesis that the total number of independently applied balance load components must always match the total number of independently measured bridge outputs or bridge output combinations. This hypothesis is supported by a control volume analysis of the inputs and outputs of a strain-gage balance. It is concluded from the control volume analysis that the loads and bridge outputs of a balance calibration data set must separately be tested for linear independence because it cannot always be guaranteed that a linearly independent load component set will result in linearly independent bridge output measurements. Simple linear math models for the loads and bridge outputs in combination with the variance inflation factor are used to test for linear independence. A highly unique and reversible mapping between the applied load component set and the measured bridge output set is guaranteed to exist if the maximum variance inflation factor of both sets is less than the literature recommended threshold of five. Data from the calibration of a six{component force balance is used to illustrate the application of the new test to real-world data.
NASA Astrophysics Data System (ADS)
Setianingsih, R.
2018-01-01
The nature of interactions that occurs among teacher, students, learning sources, and learning environment creates different settings to enhance learning. Any setting created by a teacher is affected by 3 (three) types of cognitive load: intrinsic cognitive load, extraneous cognitive load, and germane cognitive load. This study is qualitative in nature, aims to analyse the patterns of interaction that are constituted in mathematics instructions by taking into account the cognitive load theory. The subjects of this study are 21 fifth-grade students who learn mathematics in small groups and whole-class interactive lessons. The data were collected through classroom observations which were videotaped, while field notes were also taken. The data analysis revealed that students engaged in productive interaction and inquiry while they were learning mathematics in small groups or in whole class setting, in which there was a different type of cognitive load that dominantly affecting the learning processes at each setting. During learning mathematics in whole class setting, the most frequently found interaction patterns were to discuss and compare solution based on self-developed models, followed by expressing opinions. This is consistent with the principles of mathematics learning, which gives students wide opportunities to construct mathematical knowledge through individual learning, learning in small groups as well as learning in whole class settings. It means that by participating in interactive learning, the students are habitually engaged in productive interactions and high level of mathematical thinking.
A distributed grid-based watershed mercury loading model has been developed to characterize spatial and temporal dynamics of mercury from both point and non-point sources. The model simulates flow, sediment transport, and mercury dynamics on a daily time step across a diverse lan...
Web-based Communication of Water Quality Issues and Potential Solution Exploration
Many United States water bodies are impaired, i.e., do not meet applicable water quality standards. Pollutants enter water bodies from point sources (PS) and non-point sources (NPS). Loadings from PS are regulated by the Clean Water Act and permits limit them. Loadings from NPS a...
Linear Power-Flow Models in Multiphase Distribution Networks: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernstein, Andrey; Dall'Anese, Emiliano
This paper considers multiphase unbalanced distribution systems and develops approximate power-flow models where bus-voltages, line-currents, and powers at the point of common coupling are linearly related to the nodal net power injections. The linearization approach is grounded on a fixed-point interpretation of the AC power-flow equations, and it is applicable to distribution systems featuring (i) wye connections; (ii) ungrounded delta connections; (iii) a combination of wye-connected and delta-connected sources/loads; and, (iv) a combination of line-to-line and line-to-grounded-neutral devices at the secondary of distribution transformers. The proposed linear models can facilitate the development of computationally-affordable optimization and control applications -- frommore » advanced distribution management systems settings to online and distributed optimization routines. Performance of the proposed models is evaluated on different test feeders.« less
NASA Technical Reports Server (NTRS)
Sahai, Ranjana; Pierce, Larry; Cicolani, Luigi; Tischler, Mark
1998-01-01
Helicopter slung load operations are common in both military and civil contexts. The slung load adds load rigid body modes, sling stretching, and load aerodynamics to the system dynamics, which can degrade system stability and handling qualities, and reduce the operating envelope of the combined system below that of the helicopter alone. Further, the effects of the load on system dynamics vary significantly among the large range of loads, slings, and flight conditions that a utility helicopter will encounter in its operating life. In this context, military helicopters and loads are often qualified for slung load operations via flight tests which can be time consuming and expensive. One way to reduce the cost and time required to carry out these tests and generate quantitative data more readily is to provide an efficient method for analysis during the flight, so that numerous test points can be evaluated in a single flight test, with evaluations performed in near real time following each test point and prior to clearing the aircraft to the next point. Methodology for this was implemented at Ames and demonstrated in slung load flight tests in 1997 and was improved for additional flight tests in 1999. The parameters of interest for the slung load tests are aircraft handling qualities parameters (bandwidth and phase delay), stability margins (gain and phase margin), and load pendulum roots (damping and natural frequency). A procedure for the identification of these parameters from frequency sweep data was defined using the CIFER software package. CIFER is a comprehensive interactive package of utilities for frequency domain analysis previously developed at Ames for aeronautical flight test applications. It has been widely used in the US on a variety of aircraft, including some primitive flight time analysis applications.
NASA Technical Reports Server (NTRS)
1989-01-01
The stress analysis/structural design of the Pressure-Fed Booster Engine Test Bed using the existing F-1 Test Facility Test Stand at Huntsville, Alabama is described. The analysis has been coded and set up for solution on NASTRAN. A separate stress program was established to take the NASTRAN output and perform stress checks on the members. Joint checks and other necessary additional checks were performed by hand. The notes include a brief description of other programs which assist in reproducing and reviewing the NASTRAN results. The redesign of the test stand members and the stress analysis was performed per the A.I.S.C. Code. Loads on the stand consist of the loaded run tanks; wind loads; seismic loads; live loads consisting of snow and ice: live and dead loads of steel; and loaded pressurant bottle. In combining loads, wind loads and seismic loads were each combined with full live loads. Wind and seismic loads were not combined. No one third increase in allowables was taken for the environmental loads except at decks 147 and 214, where the increase was used when considering the stay rods, brackets and stay beams. Wind and seismic loads were considered from each of the four coordinate directions (i.e. N,S,E,W) to give eight basic conditions. The analysis was run with the pressurant tank mounted at level 125. One seismic condition was also run with the tank mounted at levels 169 and 214. No failures were noted with mounting at level 169, but extensive deck failure with mounting at level 214 (the loadsets used are included on the tape, but no detailed results are included in the package). Decking support beams at levels 147 and 214 are not included in the model. The stress program thus does not reduce strut lengths to the length between support beams (the struts are attached to the beams at intersection points) and gives stress ratios larger than one for some of the struts. The affected members were therefore checked by hand.
Analysis of fatigue on surface course using dissipated energy approach
NASA Astrophysics Data System (ADS)
Michael; Setyawan, A.; Pramesti, F. P.
2018-03-01
As an important transportation infrastructure, pavement is subjected to repeated vehicle loads that may cause fatigue, which often leads to cracking. The point when this cracking initiates can be determined from the energy dissipated during the loading. This research investigates fatigue in Adi Soemarmo Airport mix-design using bitumen Pen 60/70 + EVA (Ethyl Vinyl Acetate) polymer. An Indirect Tensile Fatigue Test (ITFT) was conducted using stress-controlled loading mode to determine its fatigue life. The stress levels were 500, 600, and 700 kPa, while the loading frequency and the temperature were 10 Hz and 20°C, respectively. The test exhibits strain levels for each loading cycle, which were used to determine the dissipated energy (DE). The result indicates that the DE increases when the number of loading cycles increases, due to progress of the strain levels. The values of DE are 7122.8, 8614.3, and 2654.9 J/m3 for loading levels of 500, 600, and 700 kPa, respectively, whereas the failure points for stress levels of 500, 600, and 700 kPa are 8171, 5161, and 841 cycles, respectively. Thus, the longer the time until the pavement failure point is reached (fatigue life), the greater the amount of energy that is dissipated.
Liao, Yi-Shan; Zhuo, Mu-Ning; Li, Ding-Qiang; Guo, Tai-Long
2013-08-01
In the Pearl Delta region, urban rivers have been seriously polluted, and the input of non-point source pollution materials, such as chemical oxygen demand (COD), into rivers cannot be neglected. During 2009-2010, the water qualities at eight different catchments in the Fenjiang River of Foshan city were monitored, and the COD loads for eight rivulet sewages were calculated in respect of different rainfall conditions. Interesting results were concluded in our paper. The rainfall and landuse type played important roles in the COD loading, with greater influence of rainfall than landuse type. Consequently, a COD loading formula was constructed that was defined as a function of runoff and landuse type that were derived SCS model and land use map. Loading of COD could be evaluated and predicted with the constructed formula. The mean simulation accuracy for single rainfall event was 75.51%. Long-term simulation accuracy was better than that of single rainfall. In 2009, the estimated COD loading and its loading intensity were 8 053 t and 339 kg x (hm2 x a)(-1), and the industrial land was regarded as the main source of COD pollution area. The severe non-point source pollution such as COD in Fenjiang River must be paid more attention in the future.
Stress Analysis of B-52B and B-52H Air-Launching Systems Failure-Critical Structural Components
NASA Technical Reports Server (NTRS)
Ko, William L.
2005-01-01
The operational life analysis of any airborne failure-critical structural component requires the stress-load equation, which relates the applied load to the maximum tangential tensile stress at the critical stress point. The failure-critical structural components identified are the B-52B Pegasus pylon adapter shackles, B-52B Pegasus pylon hooks, B-52H airplane pylon hooks, B-52H airplane front fittings, B-52H airplane rear pylon fitting, and the B-52H airplane pylon lower sway brace. Finite-element stress analysis was performed on the said structural components, and the critical stress point was located and the stress-load equation was established for each failure-critical structural component. The ultimate load, yield load, and proof load needed for operational life analysis were established for each failure-critical structural component.
NASA Astrophysics Data System (ADS)
Liebold, F.; Maas, H.-G.
2018-05-01
This paper deals with the determination of crack widths of concrete beams during load tests from monocular image sequences. The procedure starts in a reference image of the probe with suitable surface texture under zero load, where a large number of points is defined by an interest operator. Then a triangulated irregular network is established to connect the points. Image sequences are recorded during load tests with the load increasing continuously or stepwise, or at intermittently changing load. The vertices of the triangles are tracked through the consecutive images of the sequence with sub-pixel accuracy by least squares matching. All triangles are then analyzed for changes by principal strain calculation. For each triangle showing significant strain, a crack width is computed by a thorough geometric analysis of the relative movement of the vertices.
Effect of the Addition of 3% Co in NiTi Alloy on Loading/Unloading Force
NASA Astrophysics Data System (ADS)
Phukaoluan, A.; Dechkunakorn, S.; Anuwongnukroh, N.; Khantachawana, A.; Kaewtathip, P.; Kajornchaiyakul, J.; Wichai, W.
2017-11-01
The study evaluated the loading-unloading force in the load-deflection curve of the fabricated NiTiCo and NiTi wires. Wire alloys with Nickel, Titanium, and Cobalt (purity-99.95%) with atomic weight ratio 47Ni:50Ti:3Co and 50.6Ni:49.4Ti were prepared, sliced, and cold-rolled at 30% reduction, followed by heat treatment in a furnace at 400oC for 1 hour. The specimens of wire size of 0.016 x 0.022 inch2 were cut and subjected to three-point bending test to investigate the load-deflection curve at deflection point 0.25, 0.5, 0.75, 1.0, 1.25, and 1.5 mm. Descriptive statistic was used to evaluate each variables and independent t-test was used to compare between the groups. The results presented a load-deflection curve that resembled a typical superelastic wire. However, significant differences were seen in the loading-unloading forces between the two with an average loading force of 412.53g and 304.98g and unloading force of 292.40g and 208.08g for NiTiCo and NiTi wire, respectively. The force at each deflection point of NiTiCo in loading-unloading force was higher than NiTi wire. This study concluded that the addition of 3%Co in NiTi alloy can increase the loading-unloading force of NiTi wire but were within the range for orthodontic tooth movement.
Development of a Novel Approach for Fatigue Life Prediction of Structural Materials
2008-12-01
applied when the crack length was 8.45 mm and 14.96 mm, respectively, on these two specimens. A third specimen was subjected to a constant amplitude...The crack growth rate at the middle point (the third point) was determined from the derivative of the parabola. The stress intensity factor for...minimum load was identical in the two loading steps (Fig. 32(b)). The third specimen experienced two-step loading with identical /?-ratio in the two
Nutrient Mass Balance for the Mobile River Basin in Alabama, Georgia, and Mississippi
NASA Astrophysics Data System (ADS)
Harned, D. A.; Harvill, J. S.; McMahon, G.
2001-12-01
The source and fate of nutrients in the Mobile River drainage basin are important water-quality concerns in Alabama, Georgia, and Mississippi. Land cover in the basin is 74 percent forested, 16 percent agricultural, 2.5 percent developed, and 4 percent wetland. A nutrient mass balance calculated for 18 watersheds in the Mobile River Basin indicates that agricultural non-point nitrogen and phosphorus sources and urban non-point nitrogen sources are the most important factors associated with nutrients in the streams. Nitrogen and phosphorus inputs from atmospheric deposition, crop fertilizer, biological nitrogen fixation, animal waste, and point sources were estimated for each of the 18 drainage basins. Total basin nitrogen inputs ranged from 27 to 93 percent from atmospheric deposition (56 percent mean), 4 to 45 percent from crop fertilizer (25 percent mean), <0.01 to 31 percent from biological nitrogen fixation (8 percent mean), 2 to 14 percent from animal waste (8 percent mean), and 0.2 to 11 percent from point sources (3 percent mean). Total basin phosphorus inputs ranged from 10 to 39 percent from atmospheric deposition (26 percent mean), 7 to 51 percent from crop fertilizer (28 percent mean), 20 to 64 percent from animal waste (41 percent mean), and 0.2 to 11 percent from point sources (3 percent mean). Nutrient outputs for the watersheds were estimated by calculating instream loads and estimating nutrient uptake, or withdrawal, by crops. The difference between the total basin inputs and outputs represents nutrients that are retained or processed within the basin while moving from the point of use to the stream, or in the stream. Nitrogen output, as a percentage of the total basin nitrogen inputs, ranged from 19 to 79 percent for instream loads (35 percent mean) and from 0.01 to 32 percent for crop harvest (10 percent mean). From 53 to 87 percent (75 percent mean) of nitrogen inputs were retained within the 18 basins. Phosphorus output ranged from 9 to 29 percent for instream loads (18 percent mean) and from 0.01 to 23 percent for crop harvest (7 percent mean). The basins retained from 60 to 87 percent (74 percent mean) of phosphorous inputs. Correlation of basin nutrient output loads and concentrations with the basin inputs and correlation of output loads and concentrations with basin land use were tested using the Spearman rank test. The correlation analysis indicated that higher nitrogen concentrations in the streams are associated with urban areas and higher loads are associated with agriculture; high phosphorus output loads and concentrations are associated with agriculture. Higher nutrient loads in agricultural basins are partly an effect of basin size-- larger basins generate larger nutrient loads. Nutrient loads and concentrations showed no significant correlation to point-source inputs. Nitrogen loads were significantly (p<0.05, correlation coefficient >0.5) higher in basins with greater cropland areas. Nitrogen concentrations also increased as residential, commercial, and total urban areas increased. Phosphorus loads were positively correlated with animal-waste inputs, pasture, and total agricultural land. Phosphorus concentrations were highest in basins with the greatest amounts of row-crop agriculture.
Li, Tianhong; Bai, Fengjiao; Han, Peng; Zhang, Yuanyan
2016-11-01
Urban sprawl is a major driving force that alters local and regional hydrology and increases non-point source pollution. Using the Bao'an District in Shenzhen, China, a typical rapid urbanization area, as the study area and land-use change maps from 1988 to 2014 that were obtained by remote sensing, the contributions of different land-use types to NPS pollutant production were assessed with a localized long-term hydrologic impact assessment (L-THIA) model. The results show that the non-point source pollution load changed significantly both in terms of magnitude and spatial distribution. The loads of chemical oxygen demand, total suspended substances, total nitrogen and total phosphorus were affected by the interactions between event mean concentration and the magnitude of changes in land-use acreages and the spatial distribution. From 1988 to 2014, the loads of chemical oxygen demand, suspended substances and total phosphorus showed clearly increasing trends with rates of 132.48 %, 32.52 % and 38.76 %, respectively, while the load of total nitrogen decreased by 71.52 %. The immigrant population ratio was selected as an indicator to represent the level of rapid urbanization and industrialization in the study area, and a comparison analysis of the indicator with the four non-point source loads demonstrated that the chemical oxygen demand, total phosphorus and total nitrogen loads are linearly related to the immigrant population ratio. The results provide useful information for environmental improvement and city management in the study area.
NASA Astrophysics Data System (ADS)
Li, Tianhong; Bai, Fengjiao; Han, Peng; Zhang, Yuanyan
2016-11-01
Urban sprawl is a major driving force that alters local and regional hydrology and increases non-point source pollution. Using the Bao'an District in Shenzhen, China, a typical rapid urbanization area, as the study area and land-use change maps from 1988 to 2014 that were obtained by remote sensing, the contributions of different land-use types to NPS pollutant production were assessed with a localized long-term hydrologic impact assessment (L-THIA) model. The results show that the non-point source pollution load changed significantly both in terms of magnitude and spatial distribution. The loads of chemical oxygen demand, total suspended substances, total nitrogen and total phosphorus were affected by the interactions between event mean concentration and the magnitude of changes in land-use acreages and the spatial distribution. From 1988 to 2014, the loads of chemical oxygen demand, suspended substances and total phosphorus showed clearly increasing trends with rates of 132.48 %, 32.52 % and 38.76 %, respectively, while the load of total nitrogen decreased by 71.52 %. The immigrant population ratio was selected as an indicator to represent the level of rapid urbanization and industrialization in the study area, and a comparison analysis of the indicator with the four non-point source loads demonstrated that the chemical oxygen demand, total phosphorus and total nitrogen loads are linearly related to the immigrant population ratio. The results provide useful information for environmental improvement and city management in the study area.
Gomarus, H Karin; Althaus, Monika; Wijers, Albertus A; Minderaa, Ruud B
2006-04-01
Psychophysiological correlates of selective attention and working memory were investigated in a group of 18 healthy children using a visually presented selective memory search task. Subjects had to memorize one (load1) or 3 (load3) letters (memory set) and search for these among a recognition set consisting of 4 letters only if the letters appeared in the correct (relevant) color. Event-related potentials (ERPs) as well as alpha and theta event-related synchronization and desynchronization (ERD/ERS) were derived from the EEG that was recorded during the task. In the ERP to the memory set, a prolonged load-related positivity was found. In response to the recognition set, effects of relevance were manifested in an early frontal positivity and a later frontal negativity. Effects of load were found in a search-related negativity within the attended category and a suppression of the P3-amplitude. Theta ERS was most pronounced for the most difficult task condition during the recognition set, whereas alpha ERD showed a load-effect only during memorization. The manipulation of stimulus relevance and memory load affected both ERP components and ERD/ERS. The present paradigm may supply a useful method for studying processes of selective attention and working memory and can be used to examine group differences between healthy controls and children showing psychopathology.
Dilution: atheoretical burden or just load? A reply to Tsal and Benoni (2010).
Lavie, Nilli; Torralbo, Ana
2010-12-01
Load theory of attention proposes that distractor processing is reduced in tasks with high perceptual load that exhaust attentional capacity within task-relevant processing. In contrast, tasks of low perceptual load leave spare capacity that spills over, resulting in the perception of task-irrelevant, potentially distracting stimuli. Tsal and Benoni (2010) find that distractor response competition effects can be reduced under conditions with a high search set size but low perceptual load (due to a singleton color target). They claim that the usual effect of search set size on distractor processing is not due to attentional load but instead attribute this to lower level visual interference. Here, we propose an account for their findings within load theory. We argue that in tasks of low perceptual load but high set size, an irrelevant distractor competes with the search nontargets for remaining capacity. Thus, distractor processing is reduced under conditions in which the search nontargets receive the spillover of capacity instead of the irrelevant distractor. We report a new experiment testing this prediction. Our new results demonstrate that, when peripheral distractor processing is reduced, it is the search nontargets nearest to the target that are perceived instead. Our findings provide new evidence for the spare capacity spillover hypothesis made by load theory and rule out accounts in terms of lower level visual interference (or mere "dilution") for cases of reduced distractor processing under low load in displays of high set size. We also discuss additional evidence that discounts the viability of Tsal and Benoni's dilution account as an alternative to perceptual load.
Adhesion scratch testing - A round-robin experiment
NASA Technical Reports Server (NTRS)
Perry, A. J.; Valli, J.; Steinmann, P. A.
1988-01-01
Six sets of samples, TiN coated by chemical or physical vapor deposition methods (CVD or PVD) onto cemented carbide or high-speed steel (HSS), and TiC coated by CVD onto cemented carbide have been scratch tested using three types of commercially available scratch adhesion tester. With exception of one cemented carbide set, the reproducibility of the critical loads for any given set with a given stylus is excellent, about + or - 5 percent, and is about + or - 20 percent for different styli. Any differences in critical loads recorded for any given sample set can be attributed to the condition of the stylus (clean, new, etc.), the instrument used, the stylus itself (friction coefficient, etc.), and the sample set itself. One CVD set showed remarkably large differences in critical loads for different styli, which is thought to be related to a mechanical interaction between stylus and coating which is enhanced by a plastic deformability in the film related to the coating microstructure. The critical load for TiN on HSS increases with coating thickness, and differences in frictional conditions led to a systematic variation in the critical loads depending on the stylus used.
Monitor-based evaluation of pollutant load from urban stormwater runoff in Beijing.
Liu, Y; Che, W; Li, J
2005-01-01
As a major pollutant source to urban receiving waters, the non-point source pollution from urban runoff needs to be well studied and effectively controlled. Based on monitoring data from urban runoff pollutant sources, this article describes a systematic estimation of total pollutant loads from the urban areas of Beijing. A numerical model was developed to quantify main pollutant loads of urban runoff in Beijing. A sub-procedure is involved in this method, in which the flush process influences both the quantity and quality of stormwater runoff. A statistics-based method was applied in computing the annual pollutant load as an output of the runoff. The proportions of pollutant from point-source and non-point sources were compared. This provides a scientific basis for proper environmental input assessment of urban stormwater pollution to receiving waters, improvement of infrastructure performance, implementation of urban stormwater management, and utilization of stormwater.
Primary radiation damage of an FeCr alloy under pressure: Atomistic simulation
NASA Astrophysics Data System (ADS)
Tikhonchev, M. Yu.; Svetukhin, V. V.
2017-05-01
The primary radiation damage of a binary FeCr alloy deformed by applied mechanical loading is studied by an atomistic molecular dynamics simulation. Loading is simulated by specifying an applied pressure of 0.25, 1.0, and 2.5 GPa of both signs. Hydrostatic and uniaxial loading is considered along the [001], [111], [112], and [210] directions. The influence of loading on the energy of point defect formation and the threshold atomic displacement energy in single-component bcc iron is investigated. The 10-keV atomic displacement cascades in a "random" binary Fe-9 at % Cr alloy are simulated at an initial temperature of 300 K. The number of the point defects generated in a cascade is estimated, and the clustering of point defects and the spatial orientation of interstitial configurations are analyzed. Our results agree with the results of other researchers and supplement them.
Configuration and Sizing of a Test Fixture for Panels Under Combined Loads
NASA Technical Reports Server (NTRS)
Lovejoy, Andrew E.
2006-01-01
Future air and space structures are expected to utilize composite panels that are subjected to combined mechanical loads, such as bi-axial compression/tension, shear and pressure. Therefore, the ability to accurately predict the buckling and strength failures of such panels is important. While computational analysis can provide tremendous insight into panel response, experimental results are necessary to verify predicted performances of these panels to judge the accuracy of computational methods. However, application of combined loads is an extremely difficult task due to the complex test fixtures and set-up required. Presented herein is a comparison of several test set-ups capable of testing panels under combined loads. Configurations compared include a D-box, a segmented cylinder and a single panel set-up. The study primarily focuses on the preliminary sizing of a single panel test configuration capable of testing flat panels under combined in-plane mechanical loads. This single panel set-up appears to be best suited to the testing of both strength critical and buckling critical panels. Required actuator loads and strokes are provided for various square, flat panels.
NASA Technical Reports Server (NTRS)
Gutierrez-Lemini, Danton; McCool, Alex (Technical Monitor)
2001-01-01
A method is developed to establish the J-resistance function for an isotropic linear viscoelastic solid of constant Poisson's ratio using the single-specimen technique with constant-rate test data. The method is based on the fact that, for a test specimen of fixed crack size under constant rate, the initiation J-integral may be established from the crack size itself, the actual external load and load-point displacement at growth initiation, and the relaxation modulus of the viscoelastic solid, without knowledge of the complete test record. Since crack size alone, of the required data, would be unknown at each point of the load-vs-load-point displacement curve of a single-specimen test, an expression is derived to estimate it. With it, the physical J-integral at each point of the test record may be established. Because of its basis on single-specimen testing, not only does the method not require the use of multiple specimens with differing initial crack sizes, but avoids the need for tracking crack growth as well.
Generator voltage stabilisation for series-hybrid electric vehicles.
Stewart, P; Gladwin, D; Stewart, J; Cowley, R
2008-04-01
This paper presents a controller for use in speed control of an internal combustion engine for series-hybrid electric vehicle applications. Particular reference is made to the stability of the rectified DC link voltage under load disturbance. In the system under consideration, the primary power source is a four-cylinder normally aspirated gasoline internal combustion engine, which is mechanically coupled to a three-phase permanent magnet AC generator. The generated AC voltage is subsequently rectified to supply a lead-acid battery, and permanent magnet traction motors via three-phase full bridge power electronic inverters. Two complementary performance objectives exist. Firstly to maintain the internal combustion engine at its optimal operating point, and secondly to supply a stable 42 V supply to the traction drive inverters. Achievement of these goals minimises the transient energy storage requirements at the DC link, with a consequent reduction in both weight and cost. These objectives imply constant velocity operation of the internal combustion engine under external load disturbances and changes in both operating conditions and vehicle speed set-points. An electronically operated throttle allows closed loop engine velocity control. System time delays and nonlinearities render closed loop control design extremely problematic. A model-based controller is designed and shown to be effective in controlling the DC link voltage, resulting in the well-conditioned operation of the hybrid vehicle.
NASA Technical Reports Server (NTRS)
Van Dam, T. M.; Wahr, J. M.
1987-01-01
Atmospheric mass loads and deforms the earth's crust. By performing a convolution sum between daily, global barometric pressure data and mass loading Green's functions, the time dependent effects of atmospheric loading, including those associated with short-term synoptic storms, on surface point positioning measurements and surface gravity observations are estimated. The response for both an oceanless earth and an earth with an inverted barometer ocean is calculated. Load responses for near-coastal stations are significantly affected by the inclusion of an inverted barometer ocean. Peak-to-peak vertical displacements are frequently 15-20 mm with accompanying gravity perturbations of 3-6 micro Gal. Baseline changes can be as large as 20 mm or more. The perturbations are largest at higher latitudes and during winter months. These amplitudes are consistent with the results of Rabbel and Zschau (1985), who modeled synoptic pressure disturbances as Gaussian functions of radius around a central point. Deformation can be adequately computed using real pressure data from points within about 1000 km of the station. Knowledge of local pressure, alone, is not sufficient. Rabbel and Zschau's hypothesized corrections for these displacements, which use local pressure and the regionally averaged pressure, prove accurate at points well inland but are, in general, inadequate within a few hundred kilometers of the coast.
Metzak, Paul D.; Riley, Jennifer D.; Wang, Liang; Whitman, Jennifer C.; Ngan, Elton T. C.; Woodward, Todd S.
2012-01-01
Working memory (WM) is one of the most impaired cognitive processes in schizophrenia. Functional magnetic resonance imaging (fMRI) studies in this area have typically found a reduction in information processing efficiency but have focused on the dorsolateral prefrontal cortex. In the current study using the Sternberg Item Recognition Test, we consider networks of regions supporting WM and measure the activation of functionally connected neural networks over different WM load conditions. We used constrained principal component analysis with a finite impulse response basis set to compare the estimated hemodynamic response associated with different WM load condition for 15 healthy control subjects and 15 schizophrenia patients. Three components emerged, reflecting activated (task-positive) and deactivated (task-negative or default-mode) neural networks. Two of the components (with both task-positive and task-negative aspects) were load dependent, were involved in encoding and delay phases (one exclusively encoding and the other both encoding and delay), and both showed evidence for decreased efficiency in patients. The results suggest that WM capacity is reached sooner for schizophrenia patients as the overt levels of WM load increase, to the point that further increases in overt memory load do not increase fMRI activation, and lead to performance impairments. These results are consistent with an account holding that patients show reduced efficiency in task-positive and task-negative networks during WM and also partially support the shifted inverted-U-shaped curve theory of the relationship between WM load and fMRI activation in schizophrenia. PMID:21224491
Method and apparatus for calibrating multi-axis load cells in a dexterous robot
NASA Technical Reports Server (NTRS)
Wampler, II, Charles W. (Inventor); Platt, Jr., Robert J. (Inventor)
2012-01-01
A robotic system includes a dexterous robot having robotic joints, angle sensors adapted for measuring joint angles at a corresponding one of the joints, load cells for measuring a set of strain values imparted to a corresponding one of the load cells during a predetermined pose of the robot, and a host machine. The host machine is electrically connected to the load cells and angle sensors, and receives the joint angle values and strain values during the predetermined pose. The robot presses together mating pairs of load cells to form the poses. The host machine executes an algorithm to process the joint angles and strain values, and from the set of all calibration matrices that minimize error in force balance equations, selects the set of calibration matrices that is closest in a value to a pre-specified value. A method for calibrating the load cells via the algorithm is also provided.
Feaster, Toby D.; Conrads, Paul; Guimaraes, Wladmir B.; Sanders, Curtis L.; Bales, Jerad D.
2003-01-01
Time-series plots of dissolved-oxygen concentrations were determined for various simulated hydrologic and point-source loading conditions along a free-flowing section of the Catawba River from Lake Wylie Dam to the headwaters of Fishing Creek Reservoir in South Carolina. The U.S. Geological Survey one-dimensional dynamic-flow model, BRANCH, was used to simulate hydrodynamic data for the Branched Lagrangian Transport Model. Waterquality data were used to calibrate the Branched Lagrangian Transport Model and included concentrations of nutrients, chlorophyll a, and biochemical oxygen demand in water samples collected during two synoptic sampling surveys at 10 sites along the main stem of the Catawba River and at 3 tributaries; and continuous water temperature and dissolved-oxygen concentrations measured at 5 locations along the main stem of the Catawba River. A sensitivity analysis of the simulated dissolved-oxygen concentrations to model coefficients and data inputs indicated that the simulated dissolved-oxygen concentrations were most sensitive to watertemperature boundary data due to the effect of temperature on reaction kinetics and the solubility of dissolved oxygen. Of the model coefficients, the simulated dissolved-oxygen concentration was most sensitive to the biological oxidation rate of nitrite to nitrate. To demonstrate the utility of the Branched Lagrangian Transport Model for the Catawba River, the model was used to simulate several water-quality scenarios to evaluate the effect on the 24-hour mean dissolved-oxygen concentrations at selected sites for August 24, 1996, as simulated during the model calibration period of August 23 27, 1996. The first scenario included three loading conditions of the major effluent discharges along the main stem of the Catawba River (1) current load (as sampled in August 1996); (2) no load (all point-source loads were removed from the main stem of the Catawba River; loads from the main tributaries were not removed); and (3) fully loaded (in accordance with South Carolina Department of Health and Environmental Control National Discharge Elimination System permits). Results indicate that the 24-hour mean and minimum dissolved-oxygen concentrations for August 24, 1996, changed from the no-load condition within a range of - 0.33 to 0.02 milligram per liter and - 0.48 to 0.00 milligram per liter, respectively. Fully permitted loading conditions changed the 24-hour mean and minimum dissolved-oxygen concentrations from - 0.88 to 0.04 milligram per liter and - 1.04 to 0.00 milligram per liter, respectively. A second scenario included the addition of a point-source discharge of 25 million gallons per day to the August 1996 calibration conditions. The discharge was added at S.C. Highway 5 or at a location near Culp Island (about 4 miles downstream from S.C. Highway 5) and had no significant effect on the daily mean and minimum dissolved-oxygen concentration. A third scenario evaluated the phosphorus loading into Fishing Creek Reservoir; four loading conditions of phosphorus into Catawba River were simulated. The four conditions included fully permitted and actual loading conditions, removal of all point sources from the Catawba River, and removal of all point and nonpoint sources from Sugar Creek. Removing the point-source inputs on the Catawba River and the point and nonpoint sources in Sugar Creek reduced the organic phosphorus and orthophosphate loadings to Fishing Creek Reservoir by 78 and 85 percent, respectively.
Crumb Rubber-Concrete Panels Under Blast Loads
2010-05-01
and the samples were labeled. Samples were picked up with an overhead crane and a form spreader connected to two points on the sample, each outside...uniform loading. Shortly after test started 8 to 9 cracks developed within quarter points and 2 cracks developed through pick points where form spreader ...dynamic behaviour of recycled tyre rubber-filled concrete.” Cem. Concr. Res., 32, 1587–1596. Huang, B., Li, G., Pang, S. S., and Eggers, J. (2004
Ganni, Venkatarao
2008-08-12
A unique process cycle and apparatus design separates the consumer (cryogenic) load return flow from most of the recycle return flow of a refrigerator and/or liquefier process cycle. The refrigerator and/or liquefier process recycle return flow is recompressed by a multi-stage compressor set and the consumer load return flow is recompressed by an independent consumer load compressor set that maintains a desirable constant suction pressure using a consumer load bypass control valve and the consumer load return pressure control valve that controls the consumer load compressor's suction pressure. The discharge pressure of this consumer load compressor is thereby allowed to float at the intermediate pressure in between the first and second stage recycle compressor sets. Utilizing the unique gas management valve regulation, the unique process cycle and apparatus design in which the consumer load return flow is separate from the recycle return flow, the pressure ratios of each recycle compressor stage and all main pressures associated with the recycle return flow are allowed to vary naturally, thus providing a naturally regulated and balanced floating pressure process cycle that maintains optimal efficiency at design and off-design process cycle capacity and conditions automatically.
Ganni, Venkatarao
2007-10-09
A unique process cycle and apparatus design separates the consumer (cryogenic) load return flow from most of the recycle return flow of a refrigerator and/or liquefier process cycle. The refrigerator and/or liquefier process recycle return flow is recompressed by a multi-stage compressor set and the consumer load return flow is recompressed by an independent consumer load compressor set that maintains a desirable constant suction pressure using a consumer load bypass control valve and the consumer load return pressure control valve that controls the consumer load compressor's suction pressure. The discharge pressure of this consumer load compressor is thereby allowed to float at the intermediate pressure in between the first and second stage recycle compressor sets. Utilizing the unique gas management valve regulation, the unique process cycle and apparatus design in which the consumer load return flow is separate from the recycle return flow, the pressure ratios of each recycle compressor stage and all main pressures associated with the recycle return flow are allowed to vary naturally, thus providing a naturally regulated and balanced floating pressure process cycle that maintains optimal efficiency at design and off-design process cycle capacity and conditions automatically.
Lu, Yin-ping; Cao, Wei; Hong, Mei; Zhu, Jian-fang; Liu, Zhao; Yang, Dong-liang
2008-10-01
To investigate the relationship between pre-core G1896A point mutation of hepatitis B virus (HBV) and safety of breast feeding. Serum and breast milk samples were collected from 62 pregnant women of HBV DNA positive/HBeAg negative. PCR-solid phase hybridization was used to detect the point mutation in pre-core region G1896A of HBV from pregnant women, and HBV DNA loads in sera and breast milk were determined by fluorescence quantitative PCR (FQ-PCR). The prevalence of point mutation was 61.3% (38/62) in 62 pregnant women with HBsAg positive/HBeAg negative. The positive rate of HBV DNA in breast milk of group with point mutation (28.9%) was similar to that of group without mutation (29.2%, chi2=0.0003, P>0.05). However, The positive rate of HBV DNA in breast milk of group with high HBV loads (56.0%) was significantly higher than that of group with low HBV loads (10.8%, chi2=14.79, P<0.01). The point mutation in pre-core region G1896A of HBV dose not affect the positive rate of HBV DNA in breast milk and higher HBV DNA loads in serum of pregnant women might increase the risk of mother-infant transmission.
An evaluation of catchment-scale phosphorus mitigation using load apportionment modelling.
Greene, S; Taylor, D; McElarney, Y R; Foy, R H; Jordan, P
2011-05-01
Functional relationships between phosphorus (P) discharge and concentration mechanisms were explored using a load apportionment model (LAM) developed for use in a freshwater catchment in Ireland with fourteen years of data (1995-2008). The aim of model conceptualisation was to infer changes in point and diffuse sources from catchment P loading during P mitigation, based upon a dataset comprising geospatial and water quality data from a 256km(2) lake catchment in an intensively farmed drumlin region of the midlands of Ireland. The model was calibrated using river total P (TP), molybdate reactive P (MRP) and runoff data from seven subcatchments. Temporal and spatial heterogeneity of P sources existed within and between subcatchments; these were attributed to differences in agricultural intensity, soil type and anthropogenically-sourced effluent P loading. Catchment rivers were sensitive to flow regime, which can result in eutrophication of rivers during summer and lake enrichment from frequent flood events. For one sewage impacted river, the LAM estimated that point sourced P contributed up to of 90% of annual MRP load delivered during a hydrological year and in this river point P sources dominated flows up to 92% of days. In the other rivers, despite diffuse P forming a majority of the annual P exports, point sources of P dominated flows for up to 64% of a hydrological year. The calibrated model demonstrated that lower P export rates followed specific P mitigation measures. The LAM estimated up to 80% decreases in point MRP load after enhanced P removal at waste water treatments plants in urban subcatchments and the implementation of septic tank and agricultural bye-laws in rural subcatchments. The LAM approach provides a way to assess the long-term effectiveness of further measures to reduce P loadings in EU (International) River Basin Districts and subcatchments. Copyright © 2011 Elsevier B.V. All rights reserved.
Waveform distortion by 2-step modeling ground vibration from trains
NASA Astrophysics Data System (ADS)
Wang, F.; Chen, W.; Zhang, J.; Li, F.; Liu, H.; Chen, X.; Pan, Y.; Li, G.; Xiao, F.
2017-10-01
The 2-step procedure is widely used in numerical research on ground vibrations from trains. The ground is inconsistently represented by a simplified model in the first step and by a refined model in the second step, which may lead to distortions in the simulation results. In order to reveal this modeling error, time histories of ground-borne vibrations were computed based on the 2-step procedure and then compared with the results from a benchmark procedure of the whole system. All parameters involved were intentionally set as equal for the 2 methods, which ensures that differences in the results originated from the inconsistencies of the ground model. Excited by wheel loads of low speeds such as 60 km/h and low frequencies less than 8 Hz, the computed responses of the subgrade were quite close to the benchmarks. However, notable distortions were found in all loading cases at higher frequencies. Moreover, significant underestimation of intensity occurred when load frequencies equaled 16 Hz. This occurred not only at the subgrade but also at the points 10 m and 20 m away from the track. When the load speed was increased to 350 km/h, all computed waveforms were distorted, including the responses to the loads at very low frequencies. The modeling error found herein suggests that the ground models in the 2 steps should be calibrated in terms of frequency bands to be investigated, and the speed of train should be taken into account at the same time.
Szymocha, A M; Birczyński, A; Lalowicz, Z T; Stoch, G; Krzystyniak, M; Góra-Marek, K
2014-07-24
Deuteron NMR spectra were measured for D2O confined in NaX, NaY, and DY faujasites with various D2O loadings at temperatures ranging from T = 70 K to T = 200 K with the aim to study the molecular mobility of confined water as a function of Si/Al ratio and loading. The recorded spectra were fitted with linear combinations of representative spectral components. At low loading, with the number of water molecules per unit cell close to the abundance of sodium cations, a component related to π-jumps of water deuterons about the 2-fold symmetry axis dominated. For loadings at levels 3 times and 5 times higher than the initial loading level, Pake dublets due to rigid water deuterons dominated the recorded spectra. A set of the quadrupole coupling constant values of localized water deuterons was derived from the analysis of the Pake dublets. Their values were attributed to deuteron positions corresponding to the locations at oxygen atoms in the faujasite framework and locations within hydrogen-bonded water clusters inside faujasite cages. The contributions of the different spectral components were observed to change with increasing temperature according to the Arrhenius law with a characteristic dynamic crossover point at T = 165 K. Below T = 165 K a spectral component was observed whose contribution changed with temperature, yielding the activation energy of about 2 kJ/mol, characteristic for jumps between inversion-related water positions in clusters.
Damhorst, Gregory L.; Duarte-Guevara, Carlos; Chen, Weili; Ghonge, Tanmay; Cunningham, Brian T.; Bashir, Rashid
2015-01-01
Viral load measurements are an essential tool for the long-term clinical care of hum an immunodeficiency virus (HIV)-positive individuals. The gold standards in viral load instrumentation, however, are still too limited by their size, cost, and sophisticated operation for these measurements to be ubiquitous in remote settings with poor healthcare infrastructure, including parts of the world that are disproportionately affected by HIV infection. The challenge of developing a point-of-care platform capable of making viral load more accessible has been frequently approached but no solution has yet emerged that meets the practical requirements of low cost, portability, and ease-of-use. In this paper, we perform reverse-transcription loop-mediated isothermal amplification (RT-LAMP) on minimally processed HIV-spiked whole blood samples with a microfluidic and silicon microchip platform, and perform fluorescence measurements with a consumer smartphone. Our integrated assay shows amplification from as few as three viruses in a ~ 60 nL RT-LAMP droplet, corresponding to a whole blood concentration of 670 viruses per µL of whole blood. The technology contains greater power in a digital RT-LAMP approach that could be scaled up for the determination of viral load from a finger prick of blood in the clinical care of HIV-positive individuals. We demonstrate that all aspects of this viral load approach, from a drop of blood to imaging the RT-LAMP reaction, are compatible with lab-on-a-chip components and mobile instrumentation. PMID:26705482
Nowakowski, Alexandra C. H.
2017-01-01
Objectives: This study examines how the effects of childhood socioeconomic status (SES) may carry on into late adulthood. Methods: We examine how childhood SES affects both perceived stress and allostatic load, which is a cumulative measure of the body’s biologic response to chronic stress. We use the National Social Life, Health, and Aging Project, Waves 1 and 2, and suggest a novel method of incorporating a longitudinal allostatic load measure. Results: Individuals who grew up in low SES households have higher allostatic load scores in late adulthood, and this association is mediated mostly by educational attainment. Discussion: The longitudinal allostatic load measure shows similar results to the singular measures and allows us to include 2 time points into one outcome measure. Incorporating 2 separate time points into one measure is important because allostatic load is a measure of cumulative physiological dysregulation, and longitudinal data provide a more comprehensive measure. PMID:29226194
Lavie, Nilli; Torralbo, Ana
2010-01-01
Load theory of attention proposes that distractor processing is reduced in tasks with high perceptual load that exhaust attentional capacity within task-relevant processing. In contrast, tasks of low perceptual load leave spare capacity that spills over, resulting in the perception of task-irrelevant, potentially distracting stimuli. Tsal and Benoni (2010) find that distractor response competition effects can be reduced under conditions with a high search set size but low perceptual load (due to a singleton color target). They claim that the usual effect of search set size on distractor processing is not due to attentional load but instead attribute this to lower level visual interference. Here, we propose an account for their findings within load theory. We argue that in tasks of low perceptual load but high set size, an irrelevant distractor competes with the search nontargets for remaining capacity. Thus, distractor processing is reduced under conditions in which the search nontargets receive the spillover of capacity instead of the irrelevant distractor. We report a new experiment testing this prediction. Our new results demonstrate that, when peripheral distractor processing is reduced, it is the search nontargets nearest to the target that are perceived instead. Our findings provide new evidence for the spare capacity spillover hypothesis made by load theory and rule out accounts in terms of lower level visual interference (or mere “dilution”) for cases of reduced distractor processing under low load in displays of high set size. We also discuss additional evidence that discounts the viability of Tsal and Benoni's dilution account as an alternative to perceptual load. PMID:21133554
The impact of water loading on postglacial decay times in Hudson Bay
NASA Astrophysics Data System (ADS)
Han, Holly Kyeore; Gomez, Natalya
2018-05-01
Ongoing glacial isostatic adjustment (GIA) due to surface loading (ice and water) variations during the last glacial cycle has been contributing to sea-level changes globally throughout the Holocene, especially in regions like Canada that were heavily glaciated during the Last Glacial Maximum (LGM). The spatial and temporal distribution of GIA, as manifested in relative sea-level (RSL) change, are sensitive to the ice history and the rheological structure of the solid Earth, both of which are uncertain. It has been shown that RSL curves near the center of previously glaciated regions with no ongoing surface loading follow an exponential-like form, with the postglacial decay times associated with that form having a weak sensitivity to the details of the ice loading history. Postglacial decay time estimates thus provide a powerful datum for constraining the Earth's viscous structure and improving GIA predictions. We explore spatial patterns of postglacial decay time predictions in Hudson Bay by decomposing numerically modeled RSL changes into contributions from water and ice loading effects, and computing their relative impact on the decay times. We demonstrate that ice loading can contribute a strong geographic trend on the decay time estimates if the time window used to compute decay times includes periods that are temporally close to (i.e. contemporaneous with, or soon after) periods of active loading. This variability can be avoided by choosing a suitable starting point for the decay time window. However, more surprisingly, we show that across any adopted time window, water loading effects associated with inundation into, and postglacial flux out of, Hudson Bay and James Bay will impart significant geographic variability onto decay time estimates. We emphasize this issue by considering both maps of predicted decay times across the region and site-specific estimates, and we conclude that variability in observed decay times (whether based on existing or future data sets) may reflect this water loading signal.
Zhang, Lei; Lu, Wenxi; An, Yonglei; Li, Di; Gong, Lei
2012-01-01
The impacts of climate change on streamflow and non-point source pollutant loads in the Shitoukoumen reservoir catchment are predicted by combining a general circulation model (HadCM3) with the Soil and Water Assessment Tool (SWAT) hydrological model. A statistical downscaling model was used to generate future local scenarios of meteorological variables such as temperature and precipitation. Then, the downscaled meteorological variables were used as input to the SWAT hydrological model calibrated and validated with observations, and the corresponding changes of future streamflow and non-point source pollutant loads in Shitoukoumen reservoir catchment were simulated and analyzed. Results show that daily temperature increases in three future periods (2010-2039, 2040-2069, and 2070-2099) relative to a baseline of 1961-1990, and the rate of increase is 0.63°C per decade. Annual precipitation also shows an apparent increase of 11 mm per decade. The calibration and validation results showed that the SWAT model was able to simulate well the streamflow and non-point source pollutant loads, with a coefficient of determination of 0.7 and a Nash-Sutcliffe efficiency of about 0.7 for both the calibration and validation periods. The future climate change has a significant impact on streamflow and non-point source pollutant loads. The annual streamflow shows a fluctuating upward trend from 2010 to 2099, with an increase rate of 1.1 m(3) s(-1) per decade, and a significant upward trend in summer, with an increase rate of 1.32 m(3) s(-1) per decade. The increase in summer contributes the most to the increase of annual load compared with other seasons. The annual NH (4) (+) -N load into Shitoukoumen reservoir shows a significant downward trend with a decrease rate of 40.6 t per decade. The annual TP load shows an insignificant increasing trend, and its change rate is 3.77 t per decade. The results of this analysis provide a scientific basis for effective support of decision makers and strategies of adaptation to climate change.
Design and Construction of Mat Foundations
1989-11-01
column loads indicates the effectiveness of stiffening beams in spreading applied loads ... beams centered on rows of columns , (3) a shear and moment diagram may be constructed assuming that the column loads are point loads , (4) the mat depth...flexible consisting of precast concrete panels on a structural steel frame. Column loads , Figure 48, lead to an average pressure of 1.4 ksf. The mat
Research on wind power grid-connected operation and dispatching strategies of Liaoning power grid
NASA Astrophysics Data System (ADS)
Han, Qiu; Qu, Zhi; Zhou, Zhi; He, Xiaoyang; Li, Tie; Jin, Xiaoming; Li, Jinze; Ling, Zhaowei
2018-02-01
As a kind of clean energy, wind power has gained rapid development in recent years. Liaoning Province has abundant wind resources and the total installed capacity of wind power is in the forefront. With the large-scale wind power grid-connected operation, the contradiction between wind power utilization and peak load regulation of power grid has been more prominent. To this point, starting with the power structure and power grid installation situation of Liaoning power grid, the distribution and the space-time output characteristics of wind farm, the prediction accuracy, the curtailment and the off-grid situation of wind power are analyzed. Based on the deep analysis of the seasonal characteristics of power network load, the composition and distribution of main load are presented. Aiming at the problem between the acceptance of wind power and power grid adjustment, the scheduling strategies are given, including unit maintenance scheduling, spinning reserve, energy storage equipment settings by the analysis of the operation characteristics and the response time of thermal power units and hydroelectric units, which can meet the demand of wind power acceptance and provide a solution to improve the level of power grid dispatching.
Flexibility Considerations on the Hydrodynamic Loading on a Vertical Wedge Drop
NASA Astrophysics Data System (ADS)
Ren, Zhongshu; Wang, Zhaoyuan; Judge, Carolyn; Stern, Fred; Ikeda, Christine
2017-11-01
High-speed craft operating at in waves frequently become airborne and slam into the water surface. This fluid-structure interaction problem is important to understand in order to increase the operating envelope of these craft. The goals of the current work are to investigate both the hydrodynamic loads and the resulting structural response on a planing hull. A V-shaped wedge is dropped vertically into calm water. The hydrodynamic pressure is measured using pressure sensors at discrete points on the hull. Two hulls are studied: one is rigid and one is flexible. Predictions of the hydrodynamic loading are made using Wagner's theory, Vorus's theory, and simulations in CFDShip Iowa. These predictions assume the structure is completely rigid. These predictions of the pressure coefficient match well with the rigid hull, as expected. The spray root is tracked in the rigid experimental set and compared with the theoretical and computational models. The pressure coefficient measured on the flexible hull shows discrepancies with the predictions due to the fluid-structure interaction. These discrepancies are quantified and interpreted in light of the structural flexibility. Funding for this work is from the Office of Naval Research Grant Number N00014-16-1-3188.
Sequential structural damage diagnosis algorithm using a change point detection method
NASA Astrophysics Data System (ADS)
Noh, H.; Rajagopal, R.; Kiremidjian, A. S.
2013-11-01
This paper introduces a damage diagnosis algorithm for civil structures that uses a sequential change point detection method. The general change point detection method uses the known pre- and post-damage feature distributions to perform a sequential hypothesis test. In practice, however, the post-damage distribution is unlikely to be known a priori, unless we are looking for a known specific type of damage. Therefore, we introduce an additional algorithm that estimates and updates this distribution as data are collected using the maximum likelihood and the Bayesian methods. We also applied an approximate method to reduce the computation load and memory requirement associated with the estimation. The algorithm is validated using a set of experimental data collected from a four-story steel special moment-resisting frame and multiple sets of simulated data. Various features of different dimensions have been explored, and the algorithm was able to identify damage, particularly when it uses multidimensional damage sensitive features and lower false alarm rates, with a known post-damage feature distribution. For unknown feature distribution cases, the post-damage distribution was consistently estimated and the detection delays were only a few time steps longer than the delays from the general method that assumes we know the post-damage feature distribution. We confirmed that the Bayesian method is particularly efficient in declaring damage with minimal memory requirement, but the maximum likelihood method provides an insightful heuristic approach.
A Smart Power Electronic Multiconverter for the Residential Sector.
Guerrero-Martinez, Miguel Angel; Milanes-Montero, Maria Isabel; Barrero-Gonzalez, Fermin; Miñambres-Marcos, Victor Manuel; Romero-Cadaval, Enrique; Gonzalez-Romera, Eva
2017-05-26
The future of the grid includes distributed generation and smart grid technologies. Demand Side Management (DSM) systems will also be essential to achieve a high level of reliability and robustness in power systems. To do that, expanding the Advanced Metering Infrastructure (AMI) and Energy Management Systems (EMS) are necessary. The trend direction is towards the creation of energy resource hubs, such as the smart community concept. This paper presents a smart multiconverter system for residential/housing sector with a Hybrid Energy Storage System (HESS) consisting of supercapacitor and battery, and with local photovoltaic (PV) energy source integration. The device works as a distributed energy unit located in each house of the community, receiving active power set-points provided by a smart community EMS. This central EMS is responsible for managing the active energy flows between the electricity grid, renewable energy sources, storage equipment and loads existing in the community. The proposed multiconverter is responsible for complying with the reference active power set-points with proper power quality; guaranteeing that the local PV modules operate with a Maximum Power Point Tracking (MPPT) algorithm; and extending the lifetime of the battery thanks to a cooperative operation of the HESS. A simulation model has been developed in order to show the detailed operation of the system. Finally, a prototype of the multiconverter platform has been implemented and some experimental tests have been carried out to validate it.
A Smart Power Electronic Multiconverter for the Residential Sector
Guerrero-Martinez, Miguel Angel; Milanes-Montero, Maria Isabel; Barrero-Gonzalez, Fermin; Miñambres-Marcos, Victor Manuel; Romero-Cadaval, Enrique; Gonzalez-Romera, Eva
2017-01-01
The future of the grid includes distributed generation and smart grid technologies. Demand Side Management (DSM) systems will also be essential to achieve a high level of reliability and robustness in power systems. To do that, expanding the Advanced Metering Infrastructure (AMI) and Energy Management Systems (EMS) are necessary. The trend direction is towards the creation of energy resource hubs, such as the smart community concept. This paper presents a smart multiconverter system for residential/housing sector with a Hybrid Energy Storage System (HESS) consisting of supercapacitor and battery, and with local photovoltaic (PV) energy source integration. The device works as a distributed energy unit located in each house of the community, receiving active power set-points provided by a smart community EMS. This central EMS is responsible for managing the active energy flows between the electricity grid, renewable energy sources, storage equipment and loads existing in the community. The proposed multiconverter is responsible for complying with the reference active power set-points with proper power quality; guaranteeing that the local PV modules operate with a Maximum Power Point Tracking (MPPT) algorithm; and extending the lifetime of the battery thanks to a cooperative operation of the HESS. A simulation model has been developed in order to show the detailed operation of the system. Finally, a prototype of the multiconverter platform has been implemented and some experimental tests have been carried out to validate it. PMID:28587131
NASA Technical Reports Server (NTRS)
Johnston, G. D.; Coleman, A. D.; Portwood, J. N.; Saunders, J. M.; Porter, A. J.
1985-01-01
Load-cell and acoustic responses indicate bonding condition nondestructively. Signal recorded by load cell direct and instantaneous measure of local stiffness of material at point of impact. Separate and distinctly different measurement that sensed by microphone. Spectrum analysis of pulse obtained from debonded point will only show frequencies below 425 Hz because insulation alone does not have stiffness to support energy at higher frequencies.
SEE Transient Response of Crane Interpoint Single Output Point of Load DC-DC Converters
NASA Technical Reports Server (NTRS)
Sanders, Anthony B.; Chen, Dakai; Kim, Hak S.; Phan, Anthony M.
2011-01-01
This study was undertaken to determine the single event effect and transient susceptibility of the Crane Interpoint Maximum Flexible Power (MFP) Single Output Point of Load DC/DC Converters for transient interruptions in the output signal and for destructive and non destructive events induced by exposing it to a heavy ion beam..
Microprocessor-controlled step-down maximum-power-point tracker for photovoltaic systems
NASA Astrophysics Data System (ADS)
Mazmuder, R. K.; Haidar, S.
1992-12-01
An efficient maximum power point tracker (MPPT) has been developed and can be used with a photovoltaic (PV) array and a load which requires lower voltage than the PV array voltage to be operated. The MPPT makes the PV array to operate at maximum power point (MPP) under all insolation and temperature, which ensures the maximum amount of available PV power to be delivered to the load. The performance of the MPPT has been studied under different insolation levels.
The influence of impact direction and axial loading on the bone fracture pattern.
Cohen, Haim; Kugel, Chen; May, Hila; Medlej, Bahaa; Stein, Dan; Slon, Viviane; Brosh, Tamar; Hershkovitz, Israel
2017-08-01
The effect of the direction of the impact and the presence of axial loading on fracture patterns have not yet been established in experimental 3-point bending studies. To reveal the association between the direction of the force and the fracture pattern, with and without axial loading. A Dynatup Model POE 2000 (Instron Co.) low energy pendulum impact machine was utilized to apply impact loading on fresh pig femoral bones (n=50). The bone clamp shaft was adjusted to position the bone for three-point bending with and without additional bone compression. Four different directions of the force were applied: anterior, posterior, lateral, and medial. The impacted aspect can be distinguished from the non-impacted aspects based on the fracture pattern alone (the most fractured one); the impact point can be identified on bare bones (the area from which all oblique lines radiate and/or the presence of a chip fragment). None of our experiments (with and without compression) yielded a "true" butterfly fracture, but instead, oblique radiating lines emerged from the point of impact (also known as "false" butterfly). Impacts on the lateral and anterior aspects of the bones produce more and longer fracture lines than impacts on the contralateral side; bones subjected to an impact with axial loading are significantly more comminuted and fragmented. Under axial loading, the number of fracture lines is independent of the impact direction. Our study presents an experimental model for fracture analysis and shows that the impact direction and the presence of axial loading during impact significantly affect the fracture pattern obtained. Copyright © 2017 Elsevier B.V. All rights reserved.
Stamer, J.K.; Cherry, Rodney N.; Faye, R.E.; Kleckner, R.L.
1979-01-01
During the period April 1975 to June 1978, the U.S. Geological Survey conducted a river-quality assessment of the Upper Chattahoochee River basin in Georgia. One objective of the study was to assess the magnitudes, nature, and effects of point and non-point discharges in the Chattahoochee River basin from Atlanta to the West Point Dam. On an average annual basis and during the storm period of March 1215, 1976, non-point-source loads for most constituents analyzed were larger than point-source loads at the Whitesburg station, located on the Chattahoochee River about 40 river miles downstream of Atlanta. Most of the non-point-source constituent loads in the Atlanta-to-Whitesburg reach were from urban areas. Average annual point-source discharges accounted for about 50 percent of the dissolved nitrogen, total nitrogen, and total phosphorus loads, and about 70 percent of the dissolved phosphorus loads at Whitesburg. During weekends, power generation at the upstream Buford Dam hydroelectric facility is minimal. Streamflow at the Atlanta station during dry-weather weekends is estimated to be about 1,200 ft3/s (cubic feet per second). Average daily dissolved-oxygen concentrations of less than 5.0 mg/L (milligrams per liter) occurred often in the river, about 20 river miles downstream from Atlanta during these periods from May to November. During a low-flow period, June 1-2, 1977, five municipal point sources contributed 63 percent of the ultimate biochemical oxygen demand, 97 percent of the ammonium nitrogen, 78 percent of the total nitrogen, and 90 percent of the total phosphorus loads at the Franklin station, at the upstream end of West Point Lake. Average daily concentrations of 13 mg/L of ultimate biochemical oxygen demand and 1.8 mg/L of ammonium nitrogen were observed about 2 river miles downstream from two of the municipal point sources. Carbonaceous and nitrogenous oxygen demands caused dissolved-oxygen concentrations between 4.1 and 5.0 mg/L to occur in a 22-mile reach of the river downstream from Atlanta. Nitrogenous oxygen demands were greater than carbonaceous oxygen demands in the reach from river mile 303 to 271, and carbonaceous demands were greater from river mile 271 to 235. The heat load from the Atkinson-McDonough thermoelectric power-plants caused a decrease in the dissolved-oxygen concentrations of about 0.2 mg/L. During a critical low-flow period, a streamflow at Atlanta of about 1,800 ft3/s, with present (1977) point-source flows of 185 ft3/s containing concentrations of 45 mg/L of ultimate biochemical oxygen demand and 15 mg/L of ammonium nitrogen, results in a computed minimum dissolved-oxygen concentration of 4.7 mg/L in the river downstream from Atlanta. In the year 2000, a streamflow at Atlanta of about 1,800 ft3/s with point-source flows of 373 ft3/s containing concentrations of 45 mg/L of ultimate biochemical oxygen demand and 5.0 mg/L of ammonium nitrogen, will result in a computed minimum dissolved-oxygen concentration of 5.0 mg/L. A streamflow of about 1,050 ft3/s at Atlanta in the year 2000 will result in a dissolved-oxygen concentration of 5.0 mg/L if point-source flows contain concentrations of 15 mg/L of ultimate biochemical oxygen demand and 5.0 mg/L of ammonium nitrogen. Phytoplankton concentrations in West Point Lake, about 70 river miles downstream from Atlanta, could exceed 3 million cells per milliliter during extended low-flow periods in the summer with present point- and non-point-source nitrogen and phosphorus loads. In the year 2000, phytoplankton concentrations in West Point Lake are not likely to exceed 700,000 cells per milliliter during extended low-flow periods in the summer, if phosphorus concentrations do not exceed 1.0 mg/L in point-source discharges.
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.
1979-01-01
A two dimensional, boundary collocation stress analysis was used to analyze various round compact specimens. The influence of the round external boundary and of pin-loaded holes on stress intensity factors and crack opening displacements was determined as a function of crack-length-to-specimen-width ratios. A wide-range equation for the stress intensity factors was developed. Equations for crack-surface displacements and load-point displacements were also developed. In addition, stress intensity factors were calculated from compliance methods to demonstrate that load-displacement records must be made at the loading points and not along the crack line for crack-length-to-specimen-width ratios less than about 0.4.
Performance, emissions, and physical characteristics of a rotating combustion aircraft engine
NASA Technical Reports Server (NTRS)
Berkowitz, M.; Hermes, W. L.; Mount, R. E.; Myers, D.
1976-01-01
The RC2-75, a liquid cooled two chamber rotary combustion engine (Wankel type), designed for aircraft use, was tested and representative baseline (212 KW, 285 BHP) performance and emissions characteristics established. The testing included running fuel/air mixture control curves and varied ignition timing to permit selection of desirable and practical settings for running wide open throttle curves, propeller load curves, variable manifold pressure curves covering cruise conditions, and EPA cycle operating points. Performance and emissions data were recorded for all of the points run. In addition to the test data, information required to characterize the engine and evaluate its performance in aircraft use is provided over a range from one half to twice its present power. The exhaust emissions results are compared to the 1980 EPA requirements. Standard day take-off brake specific fuel consumption is 356 g/KW-HR (.585 lb/BHP-HR) for the configuration tested.
Test data from small solid propellant rocket motor plume measurements (FA-21)
NASA Technical Reports Server (NTRS)
Hair, L. M.; Somers, R. E.
1976-01-01
A program is described for obtaining a reliable, parametric set of measurements in the exhaust plumes of solid propellant rocket motors. Plume measurements included pressures, temperatures, forces, heat transfer rates, particle sampling, and high-speed movies. Approximately 210,000 digital data points and 15,000 movie frames were acquired. Measurements were made at points in the plumes via rake-mounted probes, and on the surface of a large plate impinged by the exhaust plume. Parametric variations were made in pressure altitude, propellant aluminum loading, impinged plate incidence angle and distance from nozzle exit to plate or rake. Reliability was incorporated by continual use of repeat runs. The test setup of the various hardware items is described along with an account of test procedures. Test results and data accuracy are discussed. Format of the data presentation is detailed. Complete data are included in the appendix.
NASA Technical Reports Server (NTRS)
Garcia, F., Jr.
1975-01-01
This paper presents a solution to a complex lifting reentry three-degree-of-freedom problem by using the calculus of variations to minimize the integral of the sum of the aerodynamics loads and heat rate input to the vehicle. The entry problem considered does not have state and/or control constraints along the trajectory. The calculus of variations method applied to this problem gives rise to a set of necessary conditions which are used to formulate a two point boundary value (TPBV) problem. This TPBV problem is then numerically solved by an improved method of perturbation functions (IMPF) using several starting co-state vectors. These vectors were chosen so that each one had a larger norm with respect to show how the envelope of convergence is significantly increased using this method and cases are presented to point this out.
Application for managing model-based material properties for simulation-based engineering
Hoffman, Edward L [Alameda, CA
2009-03-03
An application for generating a property set associated with a constitutive model of a material includes a first program module adapted to receive test data associated with the material and to extract loading conditions from the test data. A material model driver is adapted to receive the loading conditions and a property set and operable in response to the loading conditions and the property set to generate a model response for the material. A numerical optimization module is adapted to receive the test data and the model response and operable in response to the test data and the model response to generate the property set.
Design of crashworthy structures with controlled behavior in HCA framework
NASA Astrophysics Data System (ADS)
Bandi, Punit
The field of crashworthiness design is gaining more interest and attention from automakers around the world due to increasing competition and tighter safety norms. In the last two decades, topology and topometry optimization methods from structural optimization have been widely explored to improve existing designs or conceive new designs with better crashworthiness. Although many gradient-based and heuristic methods for topology- and topometry-based crashworthiness design are available these days, most of them result in stiff structures that are suitable only for a set of vehicle components in which maximizing the energy absorption or minimizing the intrusion is the main concern. However, there are some other components in a vehicle structure that should have characteristics of both stiffness and flexibility. Moreover, the load paths within the structure and potential buckle modes also play an important role in efficient functioning of such components. For example, the front bumper, side frame rails, steering column, and occupant protection devices like the knee bolster should all exhibit controlled deformation and collapse behavior. The primary objective of this research is to develop new methodologies to design crashworthy structures with controlled behavior. The well established Hybrid Cellular Automaton (HCA) method is used as the basic framework for the new methodologies, and compliant mechanism-type (sub)structures are the highlight of this research. The ability of compliant mechanisms to efficiently transfer force and/or motion from points of application of input loads to desired points within the structure is used to design solid and tubular components that exhibit controlled deformation and collapse behavior under crash loads. In addition, a new methodology for controlling the behavior of a structure under multiple crash load scenarios by adaptively changing the contributions from individual load cases is developed. Applied to practical design problems, the results demonstrate that the methodologies provide a practical tool to aid the design engineer in generating design concepts for crashworthy structures with controlled behavior. Although developed in the HCA framework, the basic ideas behind these methods are generic and can be easily implemented with other available topology- and topometry-based optimization methods.
Jackson, Timothy J; Jarrell, Shelby E; Adamson, Gregory J; Chung, Kyung Chil; Lee, Thay Q
2016-07-01
The main purpose of this study was to examine the functional characteristics of the anterior and posterior bands of the anterior bundle of the ulnar collateral ligament (UCL). Six cadaveric elbows were tested using a digital tracking system to measure the strain in the anterior band and posterior band of the anterior bundle of the UCL throughout a flexion/extension arc. The specimens were then placed in an Instron materials testing machine and loaded to failure to determine yield load and ultimate load of the UCL. The posterior band showed a linear increase in strain with increasing degrees of elbow flexion while the anterior band showed minimal change in strain throughout. The bands showed similar strain at yield load and ultimate load, demonstrating similar intrinsic properties. The anterior band of the anterior bundle of the UCL shows an isometric strain pattern through elbow range of motion, while the posterior band shows an increasing strain pattern in higher degrees of elbow flexion. Both bands show similar strain in a load to failure model, indicating insertion point, not intrinsic differences, of the bands determine the function of the anterior bundle of the UCL. This demonstrates a biomechanical rationale for UCL reconstructions using single point anatomical insertion points.
Shafiee, Hadi; Kanakasabapathy, Manoj Kumar; Juillard, Franceline; Keser, Mert; Sadasivam, Magesh; Yuksekkaya, Mehmet; Hanhauser, Emily; Henrich, Timothy J.; Kuritzkes, Daniel R.; Kaye, Kenneth M.; Demirci, Utkan
2015-01-01
We report a biosensing platform for viral load measurement through electrical sensing of viruses on a flexible plastic microchip with printed electrodes. Point-of-care (POC) viral load measurement is of paramount importance with significant impact on a broad range of applications, including infectious disease diagnostics and treatment monitoring specifically in resource-constrained settings. Here, we present a broadly applicable and inexpensive biosensing technology for accurate quantification of bioagents, including viruses in biological samples, such as plasma and artificial saliva, at clinically relevant concentrations. Our microchip fabrication is simple and mass-producible as we print microelectrodes on flexible plastic substrates using conductive inks. We evaluated the microchip technology by detecting and quantifying multiple Human Immunodeficiency Virus (HIV) subtypes (A, B, C, D, E, G, and panel), Epstein-Barr Virus (EBV), and Kaposi’s Sarcoma-associated Herpes Virus (KSHV) in a fingerprick volume (50 µL) of PBS, plasma, and artificial saliva samples for a broad range of virus concentrations between 102 copies/mL and 107 copies/mL. We have also evaluated the microchip platform with discarded, de-identified HIV-infected patient samples by comparing our microchip viral load measurement results with reverse transcriptase-quantitative polymerase chain reaction (RT-qPCR) as the gold standard method using Bland-Altman Analysis. PMID:26046668
The Effects of Ballistic and Non-Ballistic Bench Press on Mechanical Variables.
Moir, Gavin L; Munford, Shawn N; Moroski, Lindsey L; Davis, Shala E
2017-02-21
To investigate the effects of ballistic and non-ballistic bench press performed with loads equivalent to 30 and 90% 1-repetition maximum (1-RM) on mechanical variables. Eleven resistance-trained men (age: 23.0 ± 1.4 years; mass: 98.4 ± 14.4 kg) attended four testing sessions where they performed one of the following sessions: 1) three sets of five non-ballistic repetitions performed with a load equivalent to 30% 1-RM (30N-B), 2) three sets of five ballistic repetitions performed with a load equivalent to 30% 1-RM (30B), 3) three sets of four non-ballistic repetitions with a load equivalent to 90% 1-RM (90N-B), 4) three sets of four ballistic repetitions with a load equivalent to 90% 1-RM (90B). Force plates and a 3-D motion analysis system were used to determine the velocity, force, power output (PO) and work during each repetition. The heavier loads resulted in significantly greater forces applied to the barbell (mean differences: 472-783 N, p<0.001), but lower barbell velocities (mean differences: 0.85-1.20 m/s, p<0.001) and PO (mean differences: 118-492 W, p≤0.022). The ballistic conditions enhanced the mechanical variables only at the lower load with 30B producing significantly greater force (mean difference: 263 N, p<0.001), velocity (mean difference: 0.33 m/s, p<0.001), and PO (mean difference: 335 W, p<0.001) compared to 30N-B. Furthermore, the increase in PO across the 3 sets in 30B was significantly different from all other conditions (p=0.013). The total mechanical work performed was significantly greater for the conditions with the heavier loads compared to those with the lighter loads (mean differences: 3,62-5,600 J, p<0.001) and that performed during the ballistic conditions was significantly greater than that performed during the non-ballistic conditions with the same load (mean differences: 945-1,030 J, p<0.001). Ballistic bench press may be an effective exercise for developing power output and multiple sets may elicit post-activation potentiation that enhances force production. However, these benefits may be negated at heavier loads.
Liang, Shidong; Jia, Haifeng; Yang, Cong; Melching, Charles; Yuan, Yongping
2015-11-15
An environmental capacity management (ECM) system was developed to help practically implement a Total Maximum Daily Load (TMDL) for a key bay in a highly eutrophic lake in China. The ECM system consists of a simulation platform for pollutant load calculation and a pollutant load hierarchical allocation (PLHA) system. The simulation platform was developed by linking the Environmental Fluid Dynamics Code (EFDC) and Water Quality Analysis Simulation Program (WASP). In the PLHA, pollutant loads were allocated top-down in several levels based on characteristics of the pollutant sources. Different allocation methods could be used for the different levels with the advantages of each method combined over the entire allocation. Zhushan Bay of Taihu Lake, one of the most eutrophic lakes in China, was selected as a case study. The allowable loads of total nitrogen, total phosphorus, ammonia, and chemical oxygen demand were found to be 2122.2, 94.9, 1230.4, and 5260.0 t·yr(-1), respectively. The PLHA for the case study consists of 5 levels. At level 0, loads are allocated to those from the lakeshore direct drainage, atmospheric deposition, internal release, and tributary inflows. At level 1 the loads allocated to tributary inflows are allocated to the 3 tributaries. At level 2, the loads allocated to one inflow tributary are allocated to upstream areas and local sources along the tributary. At level 3, the loads allocated to local sources are allocated to the point and non-point sources from different towns. At level 4, the loads allocated to non-point sources in each town are allocated to different villages. Compared with traditional forms of pollutant load allocation methods, PLHA can combine the advantages of different methods which put different priority weights on equity and efficiency, and the PLHA is easy to understand for stakeholders and more flexible to adjust when applied in practical cases. Copyright © 2015 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
DeLeeuw, Krista E.; Mayer, Richard E.
2008-01-01
Understanding how to measure cognitive load is a fundamental challenge for cognitive load theory. In 2 experiments, 155 college students (ages = 17 to 22; 49 men and 106 women) with low domain knowledge learned from a multimedia lesson on electric motors. At 8 points during learning, their cognitive load was measured via self-report scales (mental…
A Workflow to Model Microbial Loadings in Watersheds
Many watershed models simulate overland and instream microbial fate and transport, but few actually provide loading rates on land surfaces and point sources to the water body network. This paper describes the underlying general equations for microbial loading rates associated wit...
External tank aerothermal design criteria verification, volume 1
NASA Technical Reports Server (NTRS)
Crain, William K.; Frost, Cynthia; Warmbrod, John
1990-01-01
The objective of this study was to produce an independent set of ascent environments which would serve as a check on the Rockwell IVBC-3 environments and provide an independent reevaluation of the thermal design criteria for the External Tank (ET). Design heating rates and loads were calculated at 367 acreage body point locations. Ascent flight regimes covered were lift-off, first stage ascent, Solid Rocket Booster (SRB) staging and second stage ascent through ET separation. The purpose here is to document these results, briefly describe the methodology used and present the environments along with a comparison with the Rockwell IVBC-3 counterpart. The methodology and environment summaries are given.
Development and validation of a canine radius replica for mechanical testing of orthopedic implants.
Little, Jeffrey P; Horn, Timothy J; Marcellin-Little, Denis J; Harrysson, Ola L A; West, Harvey A
2012-01-01
To design and fabricate fiberglass-reinforced composite (FRC) replicas of a canine radius and compare their mechanical properties with those of radii from dog cadavers. Replicas based on 3 FRC formulations with 33%, 50%, or 60% short-length discontinuous fiberglass by weight (7 replicas/group) and 5 radii from large (> 30-kg) dog cadavers. Bones and FRC replicas underwent nondestructive mechanical testing including 4-point bending, axial loading, and torsion and destructive testing to failure during 4-point bending. Axial, internal and external torsional, and bending stiffnesses were calculated. Axial pullout loads for bone screws placed in the replicas and cadaveric radii were also assessed. Axial, internal and external torsional, and 4-point bending stiffnesses of FRC replicas increased significantly with increasing fiberglass content. The 4-point bending stiffness of 33% and 50% FRC replicas and axial and internal torsional stiffnesses of 33% FRC replicas were equivalent to the cadaveric bone stiffnesses. Ultimate 4-point bending loads did not differ significantly between FRC replicas and bones. Ultimate screw pullout loads did not differ significantly between 33% or 50% FRC replicas and bones. Mechanical property variability (coefficient of variation) of cadaveric radii was approximately 2 to 19 times that of FRC replicas, depending on loading protocols. Within the range of properties tested, FRC replicas had mechanical properties equivalent to and mechanical property variability less than those of radii from dog cadavers. Results indicated that FRC replicas may be a useful alternative to cadaveric bones for biomechanical testing of canine bone constructs.
Method of recertifying a loaded bearing member
NASA Technical Reports Server (NTRS)
Allison, Sidney G. (Inventor)
1992-01-01
A method is described of recertifying a loaded bearing member using ultrasound testing to compensate for different equipment configurations and temperature conditions. The standard frequency F1 of a reference block is determined via an ultrasonic tone burst generated by a first pulsed phased locked loop (P2L2) equipment configuration. Once a lock point number S is determined for F1, the reference frequency F1a of the reference block is determined at this lock point number via a second P2L2 equipment configuration to permit an equipment offset compensation factor Fo1=((F1-F1a)/F1)(1000000) to be determined. Next, a reference frequency F2 of the unloaded bearing member is determined using a second P2L2 equipment configuration and is then compensated for equipment offset errors via the relationship F2+F2(Fo1)/1000000. A lock point number b is also determined for F2. A resonant frequency F3 is determined for the reference block using a third P2L2 equipment configuration to determine a second offset compensation factor F02=((F1-F3)/F1) 1000000. Next the resonant frequency F4 of the loaded bearing member is measured at lock point number b via the third P2L2 equipment configuration and the bolt load determined by the relationship (-1000000)CI(((F2-F4)/F2)-Fo2), wherein CI is a factor correlating measured frequency shift to the applied load. Temperature compensation is also performed at each point in the process.
The influence of perceptual load on age differences in selective attention.
Maylor, E A; Lavie, N
1998-12-01
The effect of perceptual load on age differences in visual selective attention was examined in 2 studies. In Experiment 1, younger and older adults made speeded choice responses indicating which of 2 target letters was present in a relevant set of letters in the center of the display while they attempted to ignore an irrelevant distractor in the periphery. The perceptual load of relevant processing was manipulated by varying the central set size. When the relevant set size was small, the adverse effect of an incompatible distractor was much greater for the older participants than for the younger ones. However, with larger relevant set sizes, this was no longer the case, with the distractor effect decreasing for older participants at lower levels of perceptual load than for younger ones. In Experiment 2, older adults were tested with the empty locations in the central set either unmarked (as in Experiment 1) or marked by small circles to form a group of 6 items irrespective of set size; the 2 conditions did not differ markedly, ruling out an explanation based entirely on perceptual grouping.
Bicycle ergometer instrumentation to determine muscle and bone forces during exercise
NASA Technical Reports Server (NTRS)
Figueroa, Fernando
1995-01-01
It is hypothesized that bone loss experienced by astronauts in zero gravity conditions may be curtailed by appropriate exercise. According to Wolf's law, bone regenerates when muscles produce stresses by pulling on the bone during daily activity and/or exercise on Earth. to use this theory to prevent or decrease bone loss, one needs to quantify musculoskeletal loads and relate them to bone density changes. In the context of the space program, it is desirable to determine musculoskeletal loads during exercise (using the bicycle ergometer in this case) so that one may make similar measurements on Earth and in space. In this manner, load measurements on Earth may be used as reference to generate similar loads during exercise in space. The work reported in this document entails a musculoskeletal load measurement system that, when complete, will provide forces at muscle insertion points and other contact points, on bone. This data will be used by Dr. Beth A. Todd, who is also a SSF working with Dr. Shackelford, as input to a finite element model of bone sections to determine stress distributions. A bicycle ergometer has been instrumented to measure parameters needed to determine musculoskeletal forces during exercise. A primary feature of the system is its compactness. It uses small/light sensors without line-of-sight requirements. The system developed includes sensors, signal processing, a data acquisition system, and software to collect the data. The sensors used include optical encoders to measure position and orientation of the pedal (foot), accelerometers to determine kinematic parameters of the shank and thigh, load cells to measure pedal forces on the sagittal plane, and EMG probes to measure muscle activity. The signals are processed using anti-aliasing filters and amplifiers. The sensors' output is digitized using 30 channels of a board mounted inside a 486 class PC. A program sets the data acquisition parameters and collects data during a time period specified by the user. The data is put directly into a file on the hard disk in binary form. The 30 channels are sampled at 200 KHz, and each 30 channel scan is done at a rate of 1000 Hz. The instrumented ergometer has been flown in the KC-135 zero-gravity (zero-g) flight to collect information needed to determine musculoskeletal forces under these conditions. Similar information has been collected in 1-g conditions for comparision with the results from the zero-g case. At this time, the sets of data from both experiments are being processed. An existing methodology will be used to determine the kinematic parameters of the shank and thigh using accelerometer and encoder data. This methodology was developed during the fellow's previous NASA/ASEE fellowship and thanks to a Director's Grant. In the future, a methodology to determine the musculoskeletal forces using Newton's Law of Motion and optimization techniques will be developed to determine forces exerted by particular muscles.
Back-Face Strain for Monitoring Stable Crack Extension in Precracked Flexure Specimens
NASA Technical Reports Server (NTRS)
Salem, Jonathan A.; Ghosn, Louis J.
2010-01-01
Calibrations relating back-face strain to crack length in precracked flexure specimens were developed for different strain gage sizes. The functions were verified via experimental compliance measurements of notched and precracked ceramic beams. Good agreement between the functions and experiments occurred, and fracture toughness was calculated via several operational methods: maximum test load and optically measured precrack length; load at 2 percent crack extension and optical precrack length; maximum load and back-face strain crack length. All the methods gave vary comparable results. The initiation toughness, K(sub Ii) , was also estimated from the initial compliance and load.The results demonstrate that stability of precracked ceramics specimens tested in four-point flexure is a common occurrence, and that methods such as remotely-monitored load-point displacement are only adequate for detecting stable extension of relatively deep cracks.
46 CFR 170.255 - Class 1 doors; permissible locations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... point at side, is at least 7 feet (2.14 meters) above the deepest load line. (b) Class 1 doors are..., the door is in a location where it will be closed at all times except when actually in use; and (2... lowest point at side is less than 7 feet (2.14 meters) above the deepest load line, an indicator light...
Program Calculates Forces in Bolted Structural Joints
NASA Technical Reports Server (NTRS)
Buder, Daniel A.
2005-01-01
FORTRAN 77 computer program calculates forces in bolts in the joints of structures. This program is used in conjunction with the NASTRAN finite-element structural-analysis program. A mathematical model of a structure is first created by approximating its load-bearing members with representative finite elements, then NASTRAN calculates the forces and moments that each finite element contributes to grid points located throughout the structure. The user selects the finite elements that correspond to structural members that contribute loads to the joints of interest, and identifies the grid point nearest to each such joint. This program reads the pertinent NASTRAN output, combines the forces and moments from the contributing elements to determine the resultant force and moment acting at each proximate grid point, then transforms the forces and moments from these grid points to the centroids of the affected joints. Then the program uses these joint loads to obtain the axial and shear forces in the individual bolts. The program identifies which bolts bear the greatest axial and/or shear loads. The program also performs a fail-safe analysis in which the foregoing calculations are repeated for a sequence of cases in which each fastener, in turn, is assumed not to transmit an axial force.
Critical capacity, travel time delays and travel time distribution of rapid mass transit systems
NASA Astrophysics Data System (ADS)
Legara, Erika Fille; Monterola, Christopher; Lee, Kee Khoon; Hung, Gih Guang
2014-07-01
We set up a mechanistic agent-based model of a rapid mass transit system. Using empirical data from Singapore's unidentifiable smart fare card, we validate our model by reconstructing actual travel demand and duration of travel statistics. We subsequently use this model to investigate two phenomena that are known to significantly affect the dynamics within the RTS: (1) overloading in trains and (2) overcrowding in the RTS platform. We demonstrate that by varying the loading capacity of trains, a tipping point emerges at which an exponential increase in the duration of travel time delays is observed. We also probe the impact on the rail system dynamics of three types of passenger growth distribution across stations: (i) Dirac delta, (ii) uniform and (iii) geometric, which is reminiscent of the effect of land use on transport. Under the assumption of a fixed loading capacity, we demonstrate the dependence of a given origin-destination (OD) pair on the flow volume of commuters in station platforms.
Propagations of fluctuations and flow separation on an unsteadily loaded airfoil
NASA Astrophysics Data System (ADS)
Tenney, Andrew; Lewalle, Jacques
2014-11-01
We analyze pressure data from 18 taps located along the surface of a DU-96-W180 airfoil in bothand steady flow conditions. The conditions were set to mimic the flow conditions experienced by a wind turbine blade under unsteady loading to test and to quantify the effects of several flow control schemes. Here we are interested in the propagation of fluctuations along the pressure and suction sides, particularly in relation to the fluctuating separation point. An unsteady phase of the incoming fluctuations is defined using Morlet wavelets, and phase-conditioned cross-correlations are calculated. Using wavelet-based pattern recognition, individual events in the pressure data are identified with several different algorithms utilizing both the original time series pressure signals and their corresponding scalograms. The data analyzed in this study was collected by G. Wang in the Skytop anechoic chamber at Syracuse University in the spring of 2013; the work of Zhe Bai on this data is also acknowledged.
A new approach to synthesis of benzyl cinnamate: Optimization by response surface methodology.
Zhang, Dong-Hao; Zhang, Jiang-Yan; Che, Wen-Cai; Wang, Yun
2016-09-01
In this work, the new approach to synthesis of benzyl cinnamate by enzymatic esterification of cinnamic acid with benzyl alcohol is optimized by response surface methodology. The effects of various reaction conditions, including temperature, enzyme loading, substrate molar ratio of benzyl alcohol to cinnamic acid, and reaction time, are investigated. A 5-level-4-factor central composite design is employed to search for the optimal yield of benzyl cinnamate. A quadratic polynomial regression model is used to analyze the experimental data at a 95% confidence level (P<0.05). The coefficient of determination of this model is found to be 0.9851. Three sets of optimum reaction conditions are established, and the verified experimental trials are performed for validating the optimum points. Under the optimum conditions (40°C, 31mg/mL enzyme loading, 2.6:1 molar ratio, 27h), the yield reaches 97.7%, which provides an efficient processes for industrial production of benzyl cinnamate. Copyright © 2016 Elsevier Ltd. All rights reserved.
Experience with small turbomachinery in a 400 watt refrigerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fuerst, J.D.
1996-12-31
A refrigerator similar to one of the Fermilab Tevatron satellites was re-configured to use turbomachinery instead of the reciprocating equipment typical of the installations. A Sulzer dry turboexpander, Creare wet turboexpander, and IHI centrifugal cold compressor have been installed and operated for about 8000 hours. Experience was gained both with the rotating machinery and with the refrigerator itself as it interfaced with the load. Equipment was set up to regulate in the same manner as the reciprocating devices had. Heat loads and operating mode were adjusted and evaluations made regarding the behavior of the devices. Individual equipment performance is described,more » as well as system behavior and overall integration of the machinery. In particular, attention is paid to the Creare wet turboexpander. This device is operated for the first time as part of a full scale refrigeration system, testing not only its performance at the design point but also its off design characteristics and behavior in transient situations.« less
Experience with small turbomachinery in a 400 watt refrigerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fuerst, J.D.
1996-09-01
A refrigerator similar to one of the Fermilab Tevatron satellites was reconfigured to use turbomachinery instead of the reciprocating equipment typical of the installations. A Sulzer dry turboexpander, Creare wet turboexpander, and IHI centrifugal cold compressor have been installed and operated for about 8000 hours. Experience was gained both with the rotating machinery and with the refrigerator itself as it interfaced with the load. Equipment was set up to regulate in the same manner as the reciprocating devices had. Heat load and operating mode were adjusted and evaluations made regarding the behavior of the devices. Individual equipment performance is describedmore » as well as system behavior and overall integration of the machinery. In particular, attention is paid to the Creare wet turboexpander. This device is operated for the first time as part of a full scale refrigeration system, testing not only its performance at the design point but also its off design characteristics and behavior in transient situations.« less
Implementation of Steiner point of fuzzy set.
Liang, Jiuzhen; Wang, Dejiang
2014-01-01
This paper deals with the implementation of Steiner point of fuzzy set. Some definitions and properties of Steiner point are investigated and extended to fuzzy set. This paper focuses on establishing efficient methods to compute Steiner point of fuzzy set. Two strategies of computing Steiner point of fuzzy set are proposed. One is called linear combination of Steiner points computed by a series of crisp α-cut sets of the fuzzy set. The other is an approximate method, which is trying to find the optimal α-cut set approaching the fuzzy set. Stability analysis of Steiner point of fuzzy set is also studied. Some experiments on image processing are given, in which the two methods are applied for implementing Steiner point of fuzzy image, and both strategies show their own advantages in computing Steiner point of fuzzy set.
Neogi, Ujjwal; Gupta, Soham; Rodridges, Rashmi; Sahoo, Pravat Nalini; Rao, Shwetha D.; Rewari, Bharat B.; Shastri, Suresh; De Costa, Ayesha; Shet, Anita
2012-01-01
Background & objectives: Monitoring of HIV-infected individuals on antiretroviral treatment (ART) ideally requires periodic viral load measurements to ascertain adequate response to treatment. While plasma viral load monitoring is widely available in high-income settings, it is rarely used in resource-limited regions because of high cost and need for sophisticated sample transport. Dried blood spot (DBS) as source specimens for viral load measurement has shown promise as an alternative to plasma specimens and is likely to be a useful tool for Indian settings. The present study was undertaken to investigate the performance of DBS in HIV-1 RNA quantification against the standard plasma viral load assay. Methods: Between April-June 2011, 130 samples were collected from HIV-1-infected (n=125) and non-infected (n=5) individuals in two district clinics in southern India. HIV-1 RNA quantification was performed from DBS and plasma using Abbott m2000rt system after manual RNA extraction. Statistical analysis included correlation, regression and Bland-Altman analysis. Results: The sensitivity of DBS viral load was 97 per cent with viral loads >3.0 log10 copies/ml. Measurable viral load (>3.0 log 10 copies/ml) results obtained for the 74 paired plasma-DBS samples showed positive correlation between both the assays (r=0.96). For clinically acceptable viral load threshold values of >5,000 copies/ml, Bland-Altman plots showed acceptable limits of agreement (−0.21 to +0.8 log10 copies/ml). The mean difference was 0.29 log10 copies/ml. The cost of DBS was $2.67 lower compared to conventional plasma viral load measurement in the setting Interpretation & conclusions: The significant positive correlation with standard plasma-based assay and lower cost of DBS viral load monitoring suggest that DBS sampling can be a feasible and economical means of viral load monitoring in HIV-infected individual in India and in other resource-limited settings globally. PMID:23391790
A Workflow to Model Microbial Loadings in Watersheds (proceedings)
Many watershed models simulate overland and instream microbial fate and transport, but few actually provide loading rates on land surfaces and point sources to the water body network. This paper describes the underlying general equations for microbial loading rates associated wit...
Study of Stand-Alone Microgrid under Condition of Faults on Distribution Line
NASA Astrophysics Data System (ADS)
Malla, S. G.; Bhende, C. N.
2014-10-01
The behavior of stand-alone microgrid is analyzed under the condition of faults on distribution feeders. During fault since battery is not able to maintain dc-link voltage within limit, the resistive dump load control is presented to do so. An inverter control is proposed to maintain balanced voltages at PCC under the unbalanced load condition and to reduce voltage unbalance factor (VUF) at load points. The proposed inverter control also has facility to protect itself from high fault current. Existing maximum power point tracker (MPPT) algorithm is modified to limit the speed of generator during fault. Extensive simulation results using MATLAB/SIMULINK established that the performance of the controllers is quite satisfactory under different fault conditions as well as unbalanced load conditions.
NASA Astrophysics Data System (ADS)
Bajoria, Kamal M.; Kaduskar, Shreya S.
2016-04-01
In this paper the structural behavior of reinforced concrete (RC) beams with smart rebars under two point loading system has been numerically studied, using Finite Element Method. The material used in this study is Super-elastic Shape Memory Alloys (SE SMAs) which contains nickel and titanium. In this study, different quantities of steel and SMA rebars have been used for reinforcement and the behavior of these models under two point bending loading system is studied. A comparison of load carrying capacity for the model between steel reinforced concrete beam and the beam reinforced with S.M.A and steel are performed. The results show that RC beams reinforced with combination of shape memory alloy and steel show better performance.
Development of a Portable Knee Rehabilitation Device That Uses Mechanical Loading.
Fitzwater, Daric; Dodge, Todd; Chien, Stanley; Yokota, Hiroki; Anwar, Sohel
2013-12-01
Joint loading is a recently developed mechanical modality, which potentially provides a therapeutic regimen to activate bone formation and prevent degradation of joint tissues. To our knowledge, however, few joint loading devices are available for clinical or point-of-care applications. Using a voice-coil actuator, we developed an electromechanical loading system appropriate for human studies and preclinical trials that should prove both safe and effective. Two specific tasks for this loading system were development of loading conditions (magnitude and frequency) suitable for humans, and provision of a convenient and portable joint loading apparatus. Desktop devices have been previously designed to evaluate the effects of various loading conditions using small and large animals. However, a portable knee loading device is more desirable from a usability point of view. In this paper, we present such a device that is designed to be portable, providing a compact, user-friendly loader. The portable device was employed to evaluate its capabilities using a human knee model. The portable device was characterized for force-pulse width modulation duty cycle and loading frequency properties. The results demonstrate that the device is capable of producing the necessary magnitude of forces at appropriate frequencies to promote the stimulation of bone growth and which can be used in clinical studies for further evaluations.
Bellomo, A; Inbar, G
1997-01-01
One of the theories of human motor control is the gamma Equilibrium Point Hypothesis. It is an attractive theory since it offers an easy control scheme where the planned trajectory shifts monotionically from an initial to a final equilibrium state. The feasibility of this model was tested by reconstructing the virtual trajectory and the stiffness profiles for movements performed with different inertial loads and examining them. Three types of movements were tested: passive movements, targeted movements, and repetitive movements. Each of the movements was performed with five different inertial loads. Plausible virtual trajectories and stiffness profiles were reconstructed based on the gamma Equilibrium Point Hypothesis for the three different types of movements performed with different inertial loads. However, the simple control strategy supported by the model, where the planned trajectory shifts monotonically from an initial to a final equilibrium state, could not be supported for targeted movements performed with added inertial load. To test the feasibility of the model further we must examine the probability that the human motor control system would choose a trajectory more complicated than the actual trajectory to control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vuckovich, M.; Burkett, J. P.; Sallustio, J.
1984-12-11
Fuel assemblies of a nuclear reactor are transferred during fueling or refueling or the like by a crane. The work-engaging fixture of the crane picks up an assembly, removes it from this slot, transfers it to the deposit site and deposits it in its slot at the deposit site. The control for the crane includes a strain gauge connected to the crane line which raises and lowers the load. The strain gauge senses the load on the crane. The signal from the strain gauge is compared with setpoints; a high-level setpoint, a low-level setpoint and a slack-line setpoint. If themore » strain gauge signal exceeds the high-level setpoint, the line drive is disabled. This event may occur during raising of a fuel assembly which encounters resistance. The high-level setpoint may be overridden under proper precautions. The line drive is also disabled if the strain gauge signal is less than the low-level setpoint. This event occurs when a fuel assembly being deposited contacts the bottom of its slot or an obstruction in, or at the entry to the slot. To preclude lateral movement and possible damage to a fuel assembly suspended from the crane line, the traverse drive of the crane is disabled once the strain-gauge exceets the lov-level setpoint. The traverse drive can only be enabled after the strain-gauge signal is less than the slack-line set-point. This occurs when the lines has been set in slack-line setting. When the line is tensioned after slack-li ne setting, the traverse drive remains enabled only if the line has been disconnected from the fuel assembly.« less
2014-01-01
Background Several footwear design characteristics are known to have detrimental effects on the foot. However, one characteristic that has received relatively little attention is the point where the sole flexes in the sagittal plane. Several footwear assessment forms assume that this should ideally be located directly under the metarsophalangeal joints (MTPJs), but this has not been directly evaluated. The aim of this study was therefore to assess the influence on plantar loading of different locations of the shoe sole flexion point. Method Twenty-one asymptomatic females with normal foot posture participated. Standardised shoes were incised directly underneath the metatarsophalangeal joints, proximal to the MTPJs or underneath the midfoot. The participants walked in a randomised sequence of the three shoes whilst plantar loading patterns were obtained using the Pedar® in-shoe pressure measurement system. The foot was divided into nine anatomically important masks, and peak pressure (PP), contact time (CT) and pressure time integral (PTI) were determined. A ratio of PP and PTI between MTPJ2-3/MTPJ1 was also calculated. Results Wearing the shoe with the sole flexion point located proximal to the MTPJs resulted in increased PP under MTPJ 4–5 (6.2%) and decreased PP under the medial midfoot compared to the sub-MTPJ flexion point (−8.4%). Wearing the shoe with the sole flexion point located under the midfoot resulted in decreased PP, CT and PTI in the medial and lateral hindfoot (PP: −4.2% and −5.1%, CT: −3.4% and −6.6%, PTI: −6.9% and −5.7%) and medial midfoot (PP: −5.9% CT: −2.9% PTI: −12.2%) compared to the other two shoes. Conclusion The findings of this study indicate that the location of the sole flexion point of the shoe influences plantar loading patterns during gait. Specifically, shoes with a sole flexion point located under the midfoot significantly decrease the magnitude and duration of loading under the midfoot and hindfoot, which may be indicative of an earlier heel lift. PMID:24642291
Chapman, Mark; Larumbe-Zabala, Eneko; Gosss-Sampson, Mark; Triplett, N Travis; Naclerio, Fernando
2018-02-22
The present study analyzed the effectiveness of the OMNI-RES (0-10) and the electromyographic signal for monitoring changes in the movement velocity during a set to muscular failure performed with different relative loads in the bench press exercise (BP). Ten males (30.8 ± 5.7 years) were evaluated on eight separate days with 48 hours of rest between sessions. After determining the 1RM value, participants performed seven sets to failure with the following relative loads ranges: 30<40%; 40<50%, 50<60%, 60%<70%, 70<80%, 80<90% and >90%. The mean accelerative velocity (MAV), the Rating of Perceived Exertion (RPE) and the normalized root mean square (N-RMS) signal from the anterior deltoids were measured for every repetition of each set. The RPE expressed after the first repetition and when the maximum value of MAV was achieved over the sets was lower (p <0.001, d >0.80) than the RPE associated with a 10% drop in MAV and at failure. Furthermore, the initial RPE was useful to distinguish different loading zones between the light relative loads (30<40% vs. 40<50% vs. 50<60%) and from these three zones to the higher relative load ranges (60 to >90%). Similar, but less clear, differences were observed for the N-RMS. In conclusion, apart from differentiating between relative loads, the RPE and in some cases N-RMS can both reflect changes associated with the initial, maximal, 10% drop in movement velocity and muscular failure during a continuous set in the BP.
NASA Astrophysics Data System (ADS)
Ianniruberto, Marco; Trevethan, Mark; Pinheiro, Arthur; Andrade, Joao Fernando; Dantas, Elton; Filizola, Naziano; Santos, André; Gualtieri, Carlo
2018-01-01
The confluence of the Negro and Solimões Rivers is an interesting study area under several points of view: it represents the second largest river confluence of the Amazon Basin; the rivers are characterized by very distinct hydrologic behaviour; and it is situated in a peculiar tectonic setting. A field investigation was undertaken to study the characteristics of this confluence, aiming to better understand the bed morphology and stratigraphy resulting from the complex interaction of geological setting, hydrodynamics, and sediment load. Two field campaigns were carried out, during low- and high-flow conditions, using high-resolution seismic, echosounding, and acoustic Doppler current profiling. A third campaign was carried out just in a limited area of the confluence, with a multi-beam echosounder. The results of these surveys provided a more detailed view of the geology, morphology and sediment distribution about the confluence.
FIBER OPTICS: Role of point defects in the photosensitivity of hydrogen-loaded phosphosilicate glass
NASA Astrophysics Data System (ADS)
Larionov, Yu V.
2010-08-01
It is shown that point defect modifications in hydrogen-loaded phosphosilicate glass (PSG) do not play a central role in determining its photosensitivity. Photochemical reactions that involve a two-step point defect modification and pre-exposure effect are incapable of accounting for photoinduced refractive index changes. It seems likely that a key role in UV-induced refractive index modifications is played by structural changes in the PSG network. Experimental data are presented that demonstrate intricate network rearrangement dynamics during UV exposure of PSG.
Experimental Nonlinear Dynamics and Snap-Through of Post-Buckled Thin Laminated Composite Plates
NASA Astrophysics Data System (ADS)
Kim, Han-Gyu
Modern aerospace systems are increasingly being designed with composite panels and plates to achieve light weight and high specific strength and stiffness. For constrained panels, thermally-induced axial loading may cause buckling of the structure, which can lead to nonlinear and potentially chaotic behavior. When post-buckled composite plates experience snap-through, they are subjected to large-amplitude deformations and in-plane compressive loading. These phenomena pose a potential threat to the structural integrity of composite structures. In this work, the nonlinear dynamic behavior of post-buckled composite plates was investigated experimentally and computationally. For the experimental work, an electrodynamic shaker was used to apply harmonic loads and the dynamic response of plate specimens was measured using a single-point displacement-sensing laser, a double-point laser vibrometer (velocity-sensing), and a set of digital image correlation cameras. Both chaotic and periodic steady-state snap-through behaviors were investigated. The experimental data were used to characterize snap-through behaviors of the post-buckled specimens and their boundaries in the harmonic forcing parameter space. The nonlinear behavior of post-buckled plates was modeled using the classical laminated plate theory (CLPT) and the von Karman strain-displacement relations. The static equilibrium paths of the post-buckled plates were analyzed using an arc-length method with a branch-switching technique. For the dynamic analysis, the nonlinear equations of motion were derived based on CLPT and the nonlinear finite element model of the equations was constructed using the Hermite cubic interpolation functions for both conforming and nonconforming elements. The numerical analyses were conducted using the model and were compared with the experimental data.
Calibration and Data Analysis of the MC-130 Air Balance
NASA Technical Reports Server (NTRS)
Booth, Dennis; Ulbrich, N.
2012-01-01
Design, calibration, calibration analysis, and intended use of the MC-130 air balance are discussed. The MC-130 balance is an 8.0 inch diameter force balance that has two separate internal air flow systems and one external bellows system. The manual calibration of the balance consisted of a total of 1854 data points with both unpressurized and pressurized air flowing through the balance. A subset of 1160 data points was chosen for the calibration data analysis. The regression analysis of the subset was performed using two fundamentally different analysis approaches. First, the data analysis was performed using a recently developed extension of the Iterative Method. This approach fits gage outputs as a function of both applied balance loads and bellows pressures while still allowing the application of the iteration scheme that is used with the Iterative Method. Then, for comparison, the axial force was also analyzed using the Non-Iterative Method. This alternate approach directly fits loads as a function of measured gage outputs and bellows pressures and does not require a load iteration. The regression models used by both the extended Iterative and Non-Iterative Method were constructed such that they met a set of widely accepted statistical quality requirements. These requirements lead to reliable regression models and prevent overfitting of data because they ensure that no hidden near-linear dependencies between regression model terms exist and that only statistically significant terms are included. Finally, a comparison of the axial force residuals was performed. Overall, axial force estimates obtained from both methods show excellent agreement as the differences of the standard deviation of the axial force residuals are on the order of 0.001 % of the axial force capacity.
Thermal performance of the CrIS passive cryocooler
NASA Astrophysics Data System (ADS)
Ghaffarian, B.; Kohrman, R.; Magner, A.
2006-02-01
The configuration, performance, and test validation of a passive radiant cooler for the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Crosstrack Infrared Sounder (CrIS) Instrument are presented. The cooler is required to provide cryogenic operation of IR focal planes. The 11 kg device, based on prior ITT Industries Space Systems Division coolers, requires virtually no power. It uses multiple thermally isolated cooling stages, each with an independent cryoradiator, operating at successively colder temperatures. The coldest stage, with a controlled set point at 81 K, cools a longwave IR (LWIR) focal plane. An intermediate stage, with a 98 K control point, cools detectors operating in MWIR and SWIR spectral regions. The warmest stage includes a fixed, integral earth shield that limits the thermal load from the earth in the NPOESS Operational Low-earth Orbiting (LEO) orbit. A study of the thermal balance and loads analysis used to evaluate the predicted cooler performance is discussed. High performance margins have been retained throughout the cooler development, fabrication and test phases of the program. The achievable in-orbit temperatures for this cooler are anticipated to be 73 K for the LWIR cooling stage and 91 K for the midwave IR (MWIR)/shortwave IR (SWIR) stage. Test results from two iterations of thermal vacuum verification testing are presented. Lessons learned from the first test, which failed to produce the predicted performance are included. The thermal model of the cooler and test configuration was used to identify deficiencies in the test targets resulting in unexpected heat loads. Corrective action was implemented to remove the heat leaks and a second test verified both the cooler performance and the correlation of the detailed thermal model.
Biomechanics of 4-point seat belt systems in frontal impacts.
Rouhana, Stephen W; Bedewi, Paul G; Kankanala, Sundeep V; Prasad, Priya; Zwolinski, Joseph J; Meduvsky, Alex G; Rupp, Jonathan D; Jeffreys, Thomas A; Schneider, Lawrence W
2003-01-01
The biomechanical behavior of 4-point seat belt systems was investigated through MADYMO modeling, dummy tests and post mortem human subject tests. This study was conducted to assess the effect of 4-point seat belts on the risk of thoracic injury in frontal impacts, to evaluate the ability to prevent submarining under the lap belt using 4-point seat belts, and to examine whether 4-point belts may induce injuries not typically observed with 3-point seat belts. The performance of two types of 4-point seat belts was compared with that of a pretensioned, load-limited, 3-point seat belt. A 3-point belt with an extra shoulder belt that "crisscrossed" the chest (X4) appeared to add constraint to the torso and increased chest deflection and injury risk. Harness style shoulder belts (V4) loaded the body in a different biomechanical manner than 3-point and X4 belts. The V4 belt appeared to shift load to the clavicles and pelvis and to reduce traction of the shoulder belt across the chest, resulting in a reduction in chest deflection by a factor of two. This is associated with a 5 to 500-fold reduction in thoracic injury risk, depending on whether one assumes 4-point belts apply concentrated or distributed load. In four of six post mortem human subjects restrained by V4 belts during 40 km/h sled tests, chest compression was zero or negative and rib fractures were nearly eliminated. Submarining was not observed in any test with post mortem human subjects. Though lumbar, sacral and pelvic injuries were noted, they are believed to be due to the artificial restraint environment (no knee bolsters, instrument panels, steering systems or airbags). While they show significant potential to reduce thoracic injury risk, there are still many issues to be resolved before 4-point belts can be considered for production vehicles. These issues include, among others, potential effects on hard and soft neck tissues, of interaction with inboard shoulder belts in farside impacts and potential effects on the fetus of latch/buckle junctions at the centerline of pregnant occupants. Work continues at Ford Motor Company to resolve these issues.
Loop Heat Pipe Operation with Thermoelectric Converters and Coupling Blocks
NASA Technical Reports Server (NTRS)
Ku, Jentung; Nagano, Hosei
2007-01-01
This paper presents theoretical and experimental studies on using thermoelectric converters (TECs) and coupling blocks to control the operating temperature of a miniature loop heat pipes (MLHP). The MLHP has two parallel evaporators and two parallel condensers, and each evaporator has its own integral compensation chamber (CC). A TEC is attached to each CC, and connected to the evaporator via a copper thermal strap. The TEC can provide both heating and cooling to the CC, therefore extending the LHP operating temperature over a larger range of the evaporator heat load. A bi-polar power supply is used for the TEC operation. The bipolar power supply automatically changes the direction of the current to the TEC, depending on whether the CC requires heating or cooling, to maintain the CC temperature at the desired set point. The TEC can also enhance the startup success by maintaining a constant CC temperature during the start-up transient. Several aluminum coupling blocks are installed between the vapor line and liquid line. The coupling blocks serve as a heat exchanger which preheats the cold returning liquid so as to reduce the amount of liquid subcooling, and hence the power required to maintain the CC at the desired set point temperature. This paper focuses on the savings of the CC control heater power afforded by the TECs when compared to traditional electric heaters. Tests were conducted by varying the evaporator power, the condenser sink temperature, the CC set point temperature, the number of coupling blocks, and the thermal conductance of the thermal strap. Test results show that the TECs are able to control the CC temperature within k0.5K under all test conditions, and the required TEC heater power is only a fraction of the required electric heater power.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2013-11-01
Maintaining comfort in a home can be challenging in hot-humid climates. At the common summer temperature set point of 75 degrees F, the perceived air temperature can vary by 11 degrees F because higher indoor humidity reduces comfort. Often the air conditioner (AC) thermostat set point is lower than the desirable cooling level to try to increase moisture removal so that the interior air is not humid or "muggy." However, this method is not always effective in maintaining indoor relative humidity (RH) or comfort. In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system, researchers frommore » the U.S. Department of Energy's Building America team Consortium of Advanced Residential Buildings (CARB) monitored the operation of two Lennox AC systems coupled with a Honeywell DH150 TrueDRY whole-house dehumidifier for a six-month period. By using a WHD to control moisture levels (latent cooling) and optimizing a central AC to control temperature (sensible cooling), improvements in comfort can be achieved while reducing utility costs. Indoor comfort for this study was defined as maintaining indoor conditions at below 60% RH and a humidity ratio of 0.012 lbm/lbm while at common dry bulb set point temperatures of 74 degrees -80 degrees F. In addition to enhanced comfort, controlling moisture to these levels can reduce the risk of other potential issues such as mold growth, pests, and building component degradation. Because a standard AC must also reduce dry bulb air temperature in order to remove moisture, a WHD is typically needed to support these latent loads when sensible heat removal is not desired.« less
NASA Astrophysics Data System (ADS)
Hasanov, Alemdar; Kawano, Alexandre
2016-05-01
Two types of inverse source problems of identifying asynchronously distributed spatial loads governed by the Euler-Bernoulli beam equation ρ (x){w}{tt}+μ (x){w}t+{({EI}(x){w}{xx})}{xx}-{T}r{u}{xx}={\\sum }m=1M{g}m(t){f}m(x), (x,t)\\in {{{Ω }}}T := (0,l)× (0,T), with hinged-clamped ends (w(0,t)={w}{xx}(0,t)=0,w(l,t) = {w}x(l,t)=0,t\\in (0,T)), are studied. Here {g}m(t) are linearly independent functions, describing an asynchronous temporal loading, and {f}m(x) are the spatial load distributions. In the first identification problem the values {ν }k(t),k=\\bar{1,K}, of the deflection w(x,t), are assumed to be known, as measured output data, in a neighbourhood of the finite set of points P:= \\{{x}k\\in (0,l),k=\\bar{1,K}\\}\\subset (0,l), corresponding to the internal points of a continuous beam, for all t\\in ]0,T[. In the second identification problem the values {θ }k(t),k=\\bar{1,K}, of the slope {w}x(x,t), are assumed to be known, as measured output data in a neighbourhood of the same set of points P for all t\\in ]0,T[. These inverse source problems will be defined subsequently as the problems ISP1 and ISP2. The general purpose of this study is to develop mathematical concepts and tools that are capable of providing effective numerical algorithms for the numerical solution of the considered class of inverse problems. Note that both measured output data {ν }k(t) and {θ }k(t) contain random noise. In the first part of the study we prove that each measured output data {ν }k(t) and {θ }k(t),k=\\bar{1,K} can uniquely determine the unknown functions {f}m\\in {H}-1(]0,l[),m=\\bar{1,M}. In the second part of the study we will introduce the input-output operators {{ K }}d :{L}2(0,T)\\mapsto {L}2(0,T),({{ K }}df)(t):= w(x,t;f),x\\in P, f(x) := ({f}1(x),\\ldots ,{f}M(x)), and {{ K }}s :{L}2(0,T)\\mapsto {L}2(0,T), ({{ K }}sf)(t):= {w}x(x,t;f), x\\in P , corresponding to the problems ISP1 and ISP2, and then reformulate these problems as the operator equations: {{ K }}df=ν and {{ K }}sf=θ , where ν (t):= ({ν }1(t),\\ldots ,{ν }K(t)) and {θ }k(t):= ({θ }1(t),\\ldots ,{θ }K(t)). Since both measured output data contain random noise, we use the most prominent regularisation method, Tikhonov regularisation, introducing the regularised cost functionals {J}1α (f):= (1/2)\\parallel {{ K }}df-ν {\\parallel }{L2(0,T)}2+(1/2)α \\parallel f{\\parallel }{L2(0,T)}2 and {J}2α (f):= (1/2)\\parallel {{ K }}sf-θ {\\parallel }{L2(0,T)}2+(1/2)α \\parallel f{\\parallel }{L2(0,T)}2. Using a priori estimates for the weak solution of the direct problem and the Tikhonov regularisation method combined with the adjoint problem approach, we prove that the Fréchet gradients {J}1\\prime (f) and {J}2\\prime (f) of both cost functionals can explicitly be derived via the corresponding weak solutions of adjoint problems and the known temporal loads {g}m(t). Moreover, we show that these gradients are Lipschitz continuous, which allows the use of gradient type iteration convergent algorithms. Two applications of the proposed theory are presented. It is shown that solvability results for inverse source problems related to the synchronous loading case, with a single interior measured data, are special cases of the obtained results for asynchronously distributed spatial load cases.
Development and Validity of a Scale of Perception of Velocity in Resistance Exercise
Bautista, Iker J.; Chirosa, Ignacio J.; Chirosa, Luis J.; Martín, Ignacio; González, Andrés; Robertson, Robert J.
2014-01-01
This aims of this study were twofold; 1) to development a new scale of perceived velocity in the bench press exercise and 2) to examine the scales concurrent validity. Twenty one physically active males with mean ±SD age, height and weights of: 27.5 ± 4.7 years, 1.77 ± 0.07 m, and 79.8 ± 10.3 kg respectively, took part in the study. The criterion variable used to test the validity of the new scale was the mean execution velocity (Velreal) of the bench press exercise. Three intensities (light loads [< 40% 1RM], medium loads [40% -70% 1RM] and heavy loads [> 70% 1RM]) were measured randomly during 5 days of testing. Perceived velocity (Velscale) was measured immediately after each exercise set using the new scale. A positive linear correlation (r range = 0.69 to 0.81) was found in all three intensities, analyzed individually, between the Velreal and Velscale. Pearson correlations showed a greater frequency of scale use resulted higher correlation values (range r = 0.88 to 0.96). This study provides evidence of the concurrent validity of a new scale of perceived velocity in the bench press exercise in trained adult males. These results suggest the exercise intensity of the bench press can be quantified quickly and effective using this new scale of perceived velocity, particularly when training for maximum power. Key Points Measurement of perception of velocity can complement other scales of perception such as the 15 category Borg scale or the OMNI-RES. The results obtained in this study show that there was a positive correlation between the perceived velocity measured by the scale and actual velocity Regular use of the new scale of perceived velocity in external resistance training provides athletes with continuous feedback of execution velocity in each repetition and set, especially with high power loads PMID:25177180
Development and validity of a scale of perception of velocity in resistance exercise.
Bautista, Iker J; Chirosa, Ignacio J; Chirosa, Luis J; Martín, Ignacio; González, Andrés; Robertson, Robert J
2014-09-01
This aims of this study were twofold; 1) to development a new scale of perceived velocity in the bench press exercise and 2) to examine the scales concurrent validity. Twenty one physically active males with mean ±SD age, height and weights of: 27.5 ± 4.7 years, 1.77 ± 0.07 m, and 79.8 ± 10.3 kg respectively, took part in the study. The criterion variable used to test the validity of the new scale was the mean execution velocity (Velreal) of the bench press exercise. Three intensities (light loads [< 40% 1RM], medium loads [40% -70% 1RM] and heavy loads [> 70% 1RM]) were measured randomly during 5 days of testing. Perceived velocity (Velscale) was measured immediately after each exercise set using the new scale. A positive linear correlation (r range = 0.69 to 0.81) was found in all three intensities, analyzed individually, between the Velreal and Velscale. Pearson correlations showed a greater frequency of scale use resulted higher correlation values (range r = 0.88 to 0.96). This study provides evidence of the concurrent validity of a new scale of perceived velocity in the bench press exercise in trained adult males. These results suggest the exercise intensity of the bench press can be quantified quickly and effective using this new scale of perceived velocity, particularly when training for maximum power. Key PointsMeasurement of perception of velocity can complement other scales of perception such as the 15 category Borg scale or the OMNI-RES.The results obtained in this study show that there was a positive correlation between the perceived velocity measured by the scale and actual velocityRegular use of the new scale of perceived velocity in external resistance training provides athletes with continuous feedback of execution velocity in each repetition and set, especially with high power loads.
Time- & Load-Dependence of Triboelectric Effect.
Pan, Shuaihang; Yin, Nian; Zhang, Zhinan
2018-02-06
Time- and load-dependent friction behavior is considered as important for a long time, due to its time-evolution and force-driving characteristics. However, its electronic behavior, mainly considered in triboelectric effect, has almost never been given the full attention and analyses from the above point of view. In this paper, by experimenting with fcc-latticed aluminum and copper friction pairs, the mechanical and electronic behaviors of friction contacts are correlated by time and load analyses, and the behind physical understanding is provided. Most importantly, the difference of "response lag" in force and electricity is discussed, the extreme points of coefficient of friction with the increasing normal loads are observed and explained with the surface properties and dynamical behaviors (i.e. wear), and the micro and macro theories linking tribo-electricity to normal load and wear (i.e. the physical explanation between coupled electrical and mechanical phenomena) are successfully developed and tested.
Blocked Force and Loading Calculations for LaRC THUNDER Actuators
NASA Technical Reports Server (NTRS)
Campbell, Joel F.
2007-01-01
An analytic approach is developed to predict the performance of LaRC Thunder actuators under load and under blocked conditions. The problem is treated with the Von Karman non-linear analysis combined with a simple Raleigh-Ritz calculation. From this, shape and displacement under load combined with voltage are calculated. A method is found to calculate the blocked force vs voltage and spring force vs distance. It is found that under certain conditions, the blocked force and displacement is almost linear with voltage. It is also found that the spring force is multivalued and has at least one bifurcation point. This bifurcation point is where the device collapses under load and locks to a different bending solution. This occurs at a particular critical load. It is shown this other bending solution has a reduced amplitude and is proportional to the original amplitude times the square of the aspect ratio.
Full Body Loading for Small Exercise Devices Project
NASA Technical Reports Server (NTRS)
Downs, Meghan; Hanson, Andrea; Newby, Nathaniel
2015-01-01
Protecting astronauts' spine, hip, and lower body musculoskeletal strength will be critical to safely and efficiently perform physically demanding vehicle egress, exploration, and habitat building activities necessary to expand human presence in the solar system. Functionally limiting decrements in musculoskeletal health are likely during Mars proving-ground and Earth-independent missions given extended transit times and the vehicle limitations for exercise devices (low-mass, small volume). Most small exercise device concepts are designed with single-cable loading, which inhibits the ability to perform full body exercises requiring two-point loading at the shoulders. Shoulder loading is critical to protect spine, hip, and lower body musculoskeletal strength. We propose a novel low-mass, low-maintenance, and rapid deploy pulley-based system that can attach to a single-cable small exercise device to enable two-point loading at the shoulders. This attachment could protect astronauts' health and save cost, space, and energy during all phases of the Journey to Mars.
Robust non-rigid registration algorithm based on local affine registration
NASA Astrophysics Data System (ADS)
Wu, Liyang; Xiong, Lei; Du, Shaoyi; Bi, Duyan; Fang, Ting; Liu, Kun; Wu, Dongpeng
2018-04-01
Aiming at the problem that the traditional point set non-rigid registration algorithm has low precision and slow convergence speed for complex local deformation data, this paper proposes a robust non-rigid registration algorithm based on local affine registration. The algorithm uses a hierarchical iterative method to complete the point set non-rigid registration from coarse to fine. In each iteration, the sub data point sets and sub model point sets are divided and the shape control points of each sub point set are updated. Then we use the control point guided affine ICP algorithm to solve the local affine transformation between the corresponding sub point sets. Next, the local affine transformation obtained by the previous step is used to update the sub data point sets and their shape control point sets. When the algorithm reaches the maximum iteration layer K, the loop ends and outputs the updated sub data point sets. Experimental results demonstrate that the accuracy and convergence of our algorithm are greatly improved compared with the traditional point set non-rigid registration algorithms.
An Elaborate Data Set Characterizing the Mechanical Response of the Foot
Erdemir, Ahmet; Sirimamilla, Pavana A.; Halloran, Jason P.; van den Bogert, Antonie J.
2010-01-01
Background Mechanical properties of the foot are responsible for its normal function and play a role in various clinical problems. Specifically, we are interested in quantification of foot mechanical properties to assist the development of computational models for movement analysis and detailed simulations of tissue deformation. Current available data are specific to a foot region and the loading scenarios are limited to a single direction. A data set that incorporates regional response, to quantify individual function of foot components, as well as overall response, to illustrate their combined operation, does not exist. Furthermore, combined three-dimensional loading scenarios while measuring the complete three-dimensional deformation response are lacking. When combined with an anatomical image data set, development of anatomically realistic and mechanically validated models becomes possible. Therefore, the goal of this study was to record and disseminate the mechanical response of a foot specimen, supported by imaging data. Method of Approach Robotic testing was conducted at the rear foot, forefoot, metatarsal heads, and the foot as a whole. Complex foot deformations were induced by single mode loading, e.g. compression, and combined loading, e.g. compression and shear. Small and large indenters were used for heel and metatarsal head loading; an elevated platform was utilized to isolate the rear foot and forefoot; and a full platform compressed the whole foot. Three-dimensional tool movements and reaction loads were recorded simultaneously. Computed tomography scans of the same specimen were collected for anatomical reconstruction a-priori. Results Three-dimensional mechanical response of the specimen was nonlinear and viscoelastic. A low stiffness region was observed starting with contact between the tool and foot regions, increasing with loading. Loading and unloading response portrayed hysteresis. Loading range ensured capturing the toe and linear regions of the load deformation curves for the dominant loading direction, with the rates approximating those of walking. Conclusion A large data set was successfully obtained to characterize the overall as well as regional mechanical response of an intact foot specimen under single and combined loads. Medical imaging complemented the mechanical testing data to establish the potential relationship between the anatomical architecture and mechanical response, and for further development of foot models that are mechanically realistic and anatomically consistent. This combined data set has been documented and disseminated in the public domain to promote future development in foot biomechanics. PMID:19725699
Stress induced phase transitions in silicon
NASA Astrophysics Data System (ADS)
Budnitzki, M.; Kuna, M.
2016-10-01
Silicon has a tremendous importance as an electronic, structural and optical material. Modeling the interaction of a silicon surface with a pointed asperity at room temperature is a major step towards the understanding of various phenomena related to brittle as well as ductile regime machining of this semiconductor. If subjected to pressure or contact loading, silicon undergoes a series of stress-driven phase transitions accompanied by large volume changes. In order to understand the material's response for complex non-hydrostatic loading situations, dedicated constitutive models are required. While a significant body of literature exists for the dislocation dominated high-temperature deformation regime, the constitutive laws used for the technologically relevant rapid low-temperature loading have severe limitations, as they do not account for the relevant phase transitions. We developed a novel finite deformation constitutive model set within the framework of thermodynamics with internal variables that captures the stress induced semiconductor-to-metal (cd-Si → β-Si), metal-to-amorphous (β-Si → a-Si) as well as amorphous-to-amorphous (a-Si → hda-Si, hda-Si → a-Si) transitions. The model parameters were identified in part directly from diamond anvil cell data and in part from instrumented indentation by the solution of an inverse problem. The constitutive model was verified by successfully predicting the transformation stress under uniaxial compression and load-displacement curves for different indenters for single loading-unloading cycles as well as repeated indentation. To the authors' knowledge this is the first constitutive model that is able to adequately describe cyclic indentation in silicon.
Zeng, Xiaodong; Bao, Xiaoyi; Chhoa, Chia Yee; Bremner, Theodore W; Brown, Anthony W; DeMerchant, Michael D; Ferrier, Graham; Kalamkarov, Alexander L; Georgiades, Anastasis V
2002-08-20
The strain measurement of a 1.65-m reinforced concrete beam by use of a distributed fiber strain sensor with a 50-cm spatial resolution and 5-cm readout resolution is reported. The strain-measurement accuracy is +/-15 microepsilon (microm/m) according to the system calibration in the laboratory environment with non-uniform-distributed strain and +/-5 microepsilon with uniform strain distribution. The strain distribution has been measured for one-point and two-point loading patterns for optical fibers embedded in pultruded glass fiber reinforced polymer (GFRP) rods and those bonded to steel reinforcing bars. In the one-point loading case, the strain deviations are +/-7 and +/-15 microepsilon for fibers embedded in the GFRP rods and fibers bonded to steel reinforcing bars, respectively, whereas the strain deviation is +/-20 microepsilon for the two-point loading case.
Schoenfeld, Brad J; Contreras, Bret; Vigotsky, Andrew D; Peterson, Mark
2016-12-01
The purpose of the present study was to evaluate muscular adaptations between heavy- and moderate-load resistance training (RT) with all other variables controlled between conditions. Nineteen resistance-trained men were randomly assigned to either a strength-type RT routine (HEAVY) that trained in a loading range of 2-4 repetitions per set (n = 10) or a hypertrophy-type RT routine (MODERATE) that trained in a loading range of 8-12 repetitions per set (n = 9). Training was carried out 3 days a week for 8 weeks. Both groups performed 3 sets of 7 exercises for the major muscle groups of the upper and lower body. Subjects were tested pre- and post-study for: 1 repetition maximum (RM) strength in the bench press and squat, upper body muscle endurance, and muscle thickness of the elbow flexors, elbow extensors, and lateral thigh. Results showed statistically greater increases in 1RM squat strength favoring HEAVY compared to MODERATE. Alternatively, statistically greater increases in lateral thigh muscle thickness were noted for MODERATE versus HEAVY. These findings indicate that heavy load training is superior for maximal strength goals while moderate load training is more suited to hypertrophy-related goals when an equal number of sets are performed between conditions.
NASA Astrophysics Data System (ADS)
Voss, Anja; Bärlund, Ilona; Punzet, Manuel; Williams, Richard; Teichert, Ellen; Malve, Olli; Voß, Frank
2010-05-01
Although catchment scale modelling of water and solute transport and transformations is a widely used technique to study pollution pathways and effects of natural changes, policies and mitigation measures there are only a few examples of global water quality modelling. This work will provide a description of the new continental-scale model of water quality WorldQual and the analysis of model simulations under changed climate and anthropogenic conditions with respect to changes in diffuse and point loading as well as surface water quality. BOD is used as an indicator of the level of organic pollution and its oxygen-depleting potential, and for the overall health of aquatic ecosystems. The first application of this new water quality model is to river systems of Europe. The model itself is being developed as part of the EU-funded SCENES Project which has the principal goal of developing new scenarios of the future of freshwater resources in Europe. The aim of the model is to determine chemical fluxes in different pathways combining analysis of water quantity with water quality. Simple equations, consistent with the availability of data on the continental scale, are used to simulate the response of in-stream BOD concentrations to diffuse and anthropogenic point loadings as well as flow dilution. Point sources are divided into manufacturing, domestic and urban loadings, whereas diffuse loadings come from scattered settlements, agricultural input (for instance livestock farming), and also from natural background sources. The model is tested against measured longitudinal gradients and time series data at specific river locations with different loading characteristics like the Thames that is driven by domestic loading and Ebro with relative high share of diffuse loading. With scenario studies the influence of climate and anthropogenic changes on European water resources shall be investigated with the following questions: 1. What percentage of river systems will have degraded water quality due to different driving forces? 2. How will climate change and changes in wastewater discharges affect water quality? For the analysis these scenario aspects are included: 1. climate with changed runoff (affecting diffuse pollution and loading from sealed areas), river discharge (causing dilution or concentration of point source pollution) and water temperature (affecting BOD degradation). 2. Point sources with changed population (affecting domestic pollution), connectivity to treatment plants (influencing domestic and manufacturing pollution as well as input from sealed areas and scattered settlements).
NASA Astrophysics Data System (ADS)
Dehbozorgi, Mohammad Reza
2000-10-01
Improvements in power system reliability have always been of interest to both power companies and customers. Since there are no sizable electrical energy storage elements in electrical power systems, the generated power should match the load demand at any given time. Failure to meet this balance may cause severe system problems, including loss of generation and system blackouts. This thesis proposes a methodology which can respond to either loss of generation or loss of load. It is based on switching of electric water heaters using power system frequency as the controlling signal. The proposed methodology encounters, and the thesis has addressed, the following associated problems. The controller must be interfaced with the existing thermostat control. When necessary to switch on loads, the water in the tank should not be overheated. Rapid switching of blocks of load, or chattering, has been considered. The contributions of the thesis are: (A) A system has been proposed which makes a significant portion of the distributed loads connected to a power system to behave in a predetermined manner to improve the power system response during disturbances. (B) The action of the proposed system is transparent to the customers. (C) The thesis proposes a simple analysis for determining the amount of such loads which might be switched and relates this amount to the size of the disturbances which can occur in the utility. (D) The proposed system acts without any formal communication links, solely using the embedded information present system-wide. (E) The methodology of the thesis proposes switching of water heater loads based on a simple, localized frequency set-point controller. The thesis has identified the consequent problem of rapid switching of distributed loads, which is referred to as chattering. (F) Two approaches have been proposed to reduce chattering to tolerable levels. (G) A frequency controller has been designed and built according to the specifications required to switch electric water heater loads in response to power system disturbances. (H) A cost analysis for building and installing the distributed frequency controller has been carried out. (I) The proposed equipment and methodology has been implemented and tested successfully. (Abstract shortened by UMI.)
Efficient Interconnection Schemes for VLSI and Parallel Computation
1989-08-01
Definition: Let R be a routing network. A set S of wires in R is a (directed) cut if it partitions the network into two sets of processors A and B ...such that every path from a processor in A to a processor in B contains a wire in S. The capacity cap(S) is the number of wires in the cut. For a set of...messages M, define the load load(M, S) of M on a cut S to be the number of messages in M from a processor in A to a processor in B . The load factor
Scudese, Estevão; Willardson, Jeffrey M; Simão, Roberto; Senna, Gilmar; de Salles, Belmiro F; Miranda, Humberto
2015-11-01
The purpose of this study was to compare different rest intervals between sets on repetition consistency and ratings of perceived exertion (RPE) during consecutive bench press sets with an absolute 3RM (3 repetition maximum) load. Sixteen trained men (23.75 ± 4.21 years; 74.63 ± 5.36 kg; 175 ± 4.64 cm; bench press relative strength: 1.44 ± 0.19 kg/kg of body mass) attended 4 randomly ordered sessions during which 5 consecutive sets of the bench press were performed with an absolute 3RM load and 1, 2, 3, or 5 minutes of rest interval between sets. The results indicated that significantly greater bench press repetitions were completed with 2, 3, and 5 minutes vs. 1-minute rest between sets (p ≤ 0.05); no significant differences were noted between the 2, 3, and 5 minutes rest conditions. For the 1-minute rest condition, performance reductions (relative to the first set) were observed commencing with the second set; whereas for the other conditions (2, 3, and 5 minutes rest), performance reductions were not evident until the third and fourth sets. The RPE values before each of the successive sets were significantly greater, commencing with the second set for the 1-minute vs. the 3 and 5 minutes rest conditions. Significant increases were also evident in RPE immediately after each set between the 1 and 5 minutes rest conditions from the second through fifth sets. These findings indicate that when utilizing an absolute 3RM load for the bench press, practitioners may prescribe a time-efficient minimum of 2 minutes rest between sets without significant impairments in repetition performance. However, lower perceived exertion levels may necessitate prescription of a minimum of 3 minutes rest between sets.
Markerless laser registration in image-guided oral and maxillofacial surgery.
Marmulla, Rüdiger; Lüth, Tim; Mühling, Joachim; Hassfeld, Stefan
2004-07-01
The use of registration markers in computer-assisted surgery is combined with high logistic costs and efforts. Markerless patient registration using laser scan surface registration techniques is a new challenging method. The present study was performed to evaluate the clinical accuracy in finding defined target points within the surgical site after markerless patient registration in image-guided oral and maxillofacial surgery. Twenty consecutive patients with different cranial diseases were scheduled for computer-assisted surgery. Data set alignment between the surgical site and the computed tomography (CT) data set was performed by markerless laser scan surface registration of the patient's face. Intraoral rigidly attached registration markers were used as target points, which had to be detected by an infrared pointer. The Surgical Segment Navigator SSN++ has been used for all procedures. SSN++ is an investigative product based on the SSN system that had previously been developed by the presenting authors with the support of Carl Zeiss (Oberkochen, Germany). SSN++ is connected to a Polaris infrared camera (Northern Digital, Waterloo, Ontario, Canada) and to a Minolta VI 900 3D digitizer (Tokyo, Japan) for high-resolution laser scanning. Minimal differences in shape between the laser scan surface and the surface generated from the CT data set could be detected. Nevertheless, high-resolution laser scan of the skin surface allows for a precise patient registration (mean deviation 1.1 mm, maximum deviation 1.8 mm). Radiation load, logistic costs, and efforts arising from the planning of computer-assisted surgery of the head can be reduced because native (markerless) CT data sets can be used for laser scan-based surface registration.
Geometrically Nonlinear Static Analysis of 3D Trusses Using the Arc-Length Method
NASA Technical Reports Server (NTRS)
Hrinda, Glenn A.
2006-01-01
Rigorous analysis of geometrically nonlinear structures demands creating mathematical models that accurately include loading and support conditions and, more importantly, model the stiffness and response of the structure. Nonlinear geometric structures often contain critical points with snap-through behavior during the response to large loads. Studying the post buckling behavior during a portion of a structure's unstable load history may be necessary. Primary structures made from ductile materials will stretch enough prior to failure for loads to redistribute producing sudden and often catastrophic collapses that are difficult to predict. The responses and redistribution of the internal loads during collapses and possible sharp snap-back of structures have frequently caused numerical difficulties in analysis procedures. The presence of critical stability points and unstable equilibrium paths are major difficulties that numerical solutions must pass to fully capture the nonlinear response. Some hurdles still exist in finding nonlinear responses of structures under large geometric changes. Predicting snap-through and snap-back of certain structures has been difficult and time consuming. Also difficult is finding how much load a structure may still carry safely. Highly geometrically nonlinear responses of structures exhibiting complex snap-back behavior are presented and analyzed with a finite element approach. The arc-length method will be reviewed and shown to predict the proper response and follow the nonlinear equilibrium path through limit points.
Herberstein, Marie E.
2017-01-01
The anchorage of structures is a crucial element of construction, both for humans and animals. Spiders use adhesive plaques to attach silk threads to substrates. Both biological and artificial adhesive structures usually have an optimal loading angle, and are prone to varying loading situations. Silk anchorages, however, must cope with loading in highly variable directions. Here we show that the detachment forces of thread anchorages of orb-web spiders are highly robust against pulling in different directions. This is gained by a two-step back-and-forth spinning pattern during the rapid production of the adhesive plaque, which shifts the thread insertion point towards the plaque centre and forms a flexible tree root-like network of branching fibres around the loading point. Using a morphometric approach and a tape-and-thread model we show that neither area, nor width of the plaque, but the shift of the loading point towards the plaque centre has the highest effect on pull-off resistance. This is explained by a circular propagation of the delamination crack with a low peeling angle. We further show that silken attachment discs are highly directional and adjusted to provide maximal performance in the upstream dragline. These results show that the way the glue is applied, crucially enhances the toughness of the anchorage without the need of additional material intake. This work is a starting point to study the evolution of tough and universal thread anchorages among spiders, and to develop bioinspired ‘instant’ anchorages of thread- and cable-like structures to a broad bandwidth of substrates. PMID:28228539
Wolff, Jonas O; Herberstein, Marie E
2017-02-01
The anchorage of structures is a crucial element of construction, both for humans and animals. Spiders use adhesive plaques to attach silk threads to substrates. Both biological and artificial adhesive structures usually have an optimal loading angle, and are prone to varying loading situations. Silk anchorages, however, must cope with loading in highly variable directions. Here we show that the detachment forces of thread anchorages of orb-web spiders are highly robust against pulling in different directions. This is gained by a two-step back-and-forth spinning pattern during the rapid production of the adhesive plaque, which shifts the thread insertion point towards the plaque centre and forms a flexible tree root-like network of branching fibres around the loading point. Using a morphometric approach and a tape-and-thread model we show that neither area, nor width of the plaque, but the shift of the loading point towards the plaque centre has the highest effect on pull-off resistance. This is explained by a circular propagation of the delamination crack with a low peeling angle. We further show that silken attachment discs are highly directional and adjusted to provide maximal performance in the upstream dragline. These results show that the way the glue is applied, crucially enhances the toughness of the anchorage without the need of additional material intake. This work is a starting point to study the evolution of tough and universal thread anchorages among spiders, and to develop bioinspired 'instant' anchorages of thread- and cable-like structures to a broad bandwidth of substrates. © 2017 The Author(s).
Wang, Ce; Bi, Jun; Zhang, Xu-Xiang; Fang, Qiang; Qi, Yi
2018-05-25
Influent river carrying cumulative watershed load plays a significant role in promoting nuisance algal bloom in river-fed lake. It is most relevant to discern in-stream water quality exceedance and evaluate the spatial relationship between risk location and potential pollution sources. However, no comprehensive studies of source tracking in watershed based on management grid have been conducted for refined water quality management, particularly for plain terrain with complex river network. In this study, field investigations were implemented during 2014 in Taige Canal watershed of Taihu Lake Basin. A Geographical Information System (GIS)-based spatial relationship model was established to characterize the spatial relationships of "point (point-source location and monitoring site)-line (river segment)-plane (catchment)." As a practical exemplification, in-time source tracking was triggered on April 15, 2015 at Huangnianqiao station, where TN and TP concentration violated the water quality standard (TN 4.0 mg/L, TP 0.15 mg/L). Of the target grid cells, 53 and 46 were identified as crucial areas having high pollution intensity for TN and TP pollution, respectively. The estimated non-point source load in each grid cell could be apportioned into different source types based on spatial pollution-related entity objects. We found that the non-point source load derived from rural sewage and livestock and poultry breeding accounted for more than 80% of total TN or TP load than another source type of crop farming. The approach in this study would be of great benefit to local authorities for identifying the serious polluted regions and efficiently making environmental policies to reduce watershed load.
A Comparison of Forecast Error Generators for Modeling Wind and Load Uncertainty
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Ning; Diao, Ruisheng; Hafen, Ryan P.
2013-12-18
This paper presents four algorithms to generate random forecast error time series, including a truncated-normal distribution model, a state-space based Markov model, a seasonal autoregressive moving average (ARMA) model, and a stochastic-optimization based model. The error time series are used to create real-time (RT), hour-ahead (HA), and day-ahead (DA) wind and load forecast time series that statistically match historically observed forecasting data sets, used for variable generation integration studies. A comparison is made using historical DA load forecast and actual load values to generate new sets of DA forecasts with similar stoical forecast error characteristics. This paper discusses and comparesmore » the capabilities of each algorithm to preserve the characteristics of the historical forecast data sets.« less
Multiscale registration algorithm for alignment of meshes
NASA Astrophysics Data System (ADS)
Vadde, Srikanth; Kamarthi, Sagar V.; Gupta, Surendra M.
2004-03-01
Taking a multi-resolution approach, this research work proposes an effective algorithm for aligning a pair of scans obtained by scanning an object's surface from two adjacent views. This algorithm first encases each scan in the pair with an array of cubes of equal and fixed size. For each scan in the pair a surrogate scan is created by the centroids of the cubes that encase the scan. The Gaussian curvatures of points across the surrogate scan pair are compared to find the surrogate corresponding points. If the difference between the Gaussian curvatures of any two points on the surrogate scan pair is less than a predetermined threshold, then those two points are accepted as a pair of surrogate corresponding points. The rotation and translation values between the surrogate scan pair are determined by using a set of surrogate corresponding points. Using the same rotation and translation values the original scan pairs are aligned. The resulting registration (or alignment) error is computed to check the accuracy of the scan alignment. When the registration error becomes acceptably small, the algorithm is terminated. Otherwise the above process is continued with cubes of smaller and smaller sizes until the algorithm is terminated. However at each finer resolution the search space for finding the surrogate corresponding points is restricted to the regions in the neighborhood of the surrogate points that were at found at the preceding coarser level. The surrogate corresponding points, as the resolution becomes finer and finer, converge to the true corresponding points on the original scans. This approach offers three main benefits: it improves the chances of finding the true corresponding points on the scans, minimize the adverse effects of noise in the scans, and reduce the computational load for finding the corresponding points.
NASA Astrophysics Data System (ADS)
Mahmoudabadi, H.; Briggs, G.
2016-12-01
Gridded data sets, such as geoid models or datum shift grids, are commonly used in coordinate transformation algorithms. Grid files typically contain known or measured values at regular fixed intervals. The process of computing a value at an unknown location from the values in the grid data set is called "interpolation". Generally, interpolation methods predict a value at a given point by computing a weighted average of the known values in the neighborhood of the point. Geostatistical Kriging is a widely used interpolation method for irregular networks. Kriging interpolation first analyzes the spatial structure of the input data, then generates a general model to describe spatial dependencies. This model is used to calculate values at unsampled locations by finding direction, shape, size, and weight of neighborhood points. Because it is based on a linear formulation for the best estimation, Kriging it the optimal interpolation method in statistical terms. The Kriging interpolation algorithm produces an unbiased prediction, as well as the ability to calculate the spatial distribution of uncertainty, allowing you to estimate the errors in an interpolation for any particular point. Kriging is not widely used in geospatial applications today, especially applications that run on low power devices or deal with large data files. This is due to the computational power and memory requirements of standard Kriging techniques. In this paper, improvements are introduced in directional kriging implementation by taking advantage of the structure of the grid files. The regular spacing of points simplifies finding the neighborhood points and computing their pairwise distances, reducing the the complexity and improving the execution time of the Kriging algorithm. Also, the proposed method iteratively loads small portion of interest areas in different directions to reduce the amount of required memory. This makes the technique feasible on almost any computer processor. Comparison between kriging and other standard interpolation methods demonstrated more accurate estimations in less denser data files.
Flexible Power Distribution Based on Point of Load Converters
NASA Astrophysics Data System (ADS)
Dhallewin, G.; Galiana, D.; Mollard, J. M.; Schaper, W.; Strixner, E.; Tonicello, F.; Triggianese, M.
2014-08-01
Present digital electronic loads require low voltages and suffer from high currents. In addition, they need several different voltage levels to supply the different parts of digital devices like the core, the input/output I/F, etc. Distributed Power Architectures (DPA) with point-of- load (POL) converters (synchronous buck type) offer excellent performance in term of efficiency and load step behaviour. They occupy little PCB area and are well suited for very low voltage (VLV) DC conversion (1V to 3.3V). The paper presents approaches to architectural design of POL based supplies including redundancy and protection as well as the requirements on a European hardware implementation. The main driver of the analysis is the flexibility of each element (DC/DC converter, protection, POL core) to cover a wide range of space applications.
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Jacking loads. 23.507 Section 23.507 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... inertia forces so as to result in no change in the direction of the resultant loads at the jack points. (c...
NASA Technical Reports Server (NTRS)
Houbolt, J. C.
1972-01-01
Criteria and guidelines are presented for combining loads that develop during the ascent phase of a space flight. The primary load-caring structure is discussed including the basic tank and interconnecting members, engine support mounts and connections to tank structure, transition structures between stages, payload shrouds, and the basic support points at separation planes.
Patterson, Carson; Raschner, Christian; Platzer, Hans-Peter
2009-05-01
The purpose of this paper was to investigate the power-load relationship and to compare power variables and bilateral force imbalances between sexes with squat jumps. Twenty men and 17 women, all members of the Austrian alpine ski team (junior and European Cup), performed unloaded and loaded (barbell loads equal to 25, 50, 75, and 100% body weight [BW]) squat jumps with free weights using a specially designed spotting system. Ground reaction force records from 2 force platforms were used to calculate relative average power (P), relative average power in the first 100 ms of the jump (P01), relative average power in the first 200 ms of the jump (P02), jump height, percentage of best jump height (%Jump), and maximal force difference between dominant and nondominant leg (Fmaxdiff). The men displayed significantly higher values at all loads for P and jump height (p < 0.05). No significant differences were found in P01. The men had significantly higher P02 at all loads except 75% BW). Maximum P was reached at light loads (men at 25% BW and women at 0% BW), and P decreased uniformly thereafter. Individual power-load curves show a deflection point. It is proposed that the load where the power-load deflection point occurs be used as the power training load and not the load at which maximum P is reached. It is also proposed that loads not be described in %1-repetition maximum (RM), but as %BW. This system can be used to safely assess and train power with loaded jumps and free weights.
Schnee, Sarah Valerie; Pfeil, Johannes; Ihling, Clara Marlene; Tabatabai, Julia; Schnitzler, Paul
2017-12-13
Respiratory syncytial virus (RSV) is the most important cause of severe acute respiratory tract infection in young children. Alere i RSV is a novel molecular rapid test which identifies respiratory syncytial virus in less than 13 min. We evaluated the clinical performance of the Alere i RSV assay in a pediatric point-of-care setting during winter season 2016 / 2017. Test results from 518 nasopharyngeal swab samples were compared to a real-time reverse transcription PCR reference standard. The overall sensitivity and specificity of the Alere i RSV test assay was 93% (CI 95 89% - 96%) and 96% (CI 95 93% - 98%), respectively. Alere i RSV performed well in children of all age groups. An optimal sensitivity of 98% (CI 95 94% - 100%) and specificity of 96% (CI 95 90% - 99%) was obtained in children < 6 months. In children ≥ 2 years, sensitivity and specificity remained at 87% (CI 95 73% - 96%) and 98% (CI 95 92% - 100%), respectively. False negative Alere i RSV test results mostly occurred in samples with low viral load (mean CT value 31.1; CI 95 29.6 - 32.6). The Alere i RSV assay is easy to use and can be operated after minimal initial training. Test results are available within 13 min, with most RSV positive samples being identified after approximately 5 min. The Alere i RSV assay has the potential to facilitate the detection of RSV in pediatric point-of-care settings.
Building laboratory capacity to support HIV care in Nigeria: Harvard/APIN PEPFAR, 2004-2012.
Hamel, Donald J; Sankalé, Jean-Louis; Samuels, Jay Osi; Sarr, Abdoulaye D; Chaplin, Beth; Ofuche, Eke; Meloni, Seema T; Okonkwo, Prosper; Kanki, Phyllis J
From 2004-2012, the Harvard/AIDS Prevention Initiative in Nigeria, funded through the US President's Emergency Plan for AIDS Relief programme, scaled up HIV care and treatment services in Nigeria. We describe the methodologies and collaborative processes developed to improve laboratory capacity significantly in a resource-limited setting. These methods were implemented at 35 clinic and laboratory locations. Systems were established and modified to optimise numerous laboratory processes. These included strategies for clinic selection and management, equipment and reagent procurement, supply chains, laboratory renovations, equipment maintenance, electronic data management, quality development programmes and trainings. Over the eight-year programme, laboratories supported 160 000 patients receiving HIV care in Nigeria, delivering over 2.5 million test results, including regular viral load quantitation. External quality assurance systems were established for CD4+ cell count enumeration, blood chemistries and viral load monitoring. Laboratory equipment platforms were improved and standardised and use of point-of-care analysers was expanded. Laboratory training workshops supported laboratories toward increasing staff skills and improving overall quality. Participation in a World Health Organisation-led African laboratory quality improvement system resulted in significant gains in quality measures at five laboratories. Targeted implementation of laboratory development processes, during simultaneous scale-up of HIV treatment programmes in a resource-limited setting, can elicit meaningful gains in laboratory quality and capacity. Systems to improve the physical laboratory environment, develop laboratory staff, create improvements to reduce costs and increase quality are available for future health and laboratory strengthening programmes. We hope that the strategies employed may inform and encourage the development of other laboratories in resource-limited settings.
Moppett, Iain K; Greenhaff, Paul L; Ollivere, Ben J; Joachim, Theophillus; Lobo, Dileep N; Rowlands, Martin
2014-12-04
Trauma such as hip fracture initiates a neurohumoral stress response that changes the balance between anabolism and catabolism resulting in muscle breakdown and reduced mobilisation. Various studies have demonstrated a reduction in catabolism with pre-operative carbohydrate loading but only in an elective setting. This is a two-centre, randomised double-blinded trial in the United Kingdom. Sample size will be 30 patients (approximately 15 from each centre). Randomisation will be web based using computer-generated concealed tables. Both participants and investigators will be blinded to group allocation. Participants will be >70 years of age, cognitively intact (Abbreviated Mental Score ≥ 7), able to give informed consent, and admitted directly through the emergency department with fractured neck of femur requiring hemiarthroplasty. Intervention will consist of two carbohydrate drinks (Nutricia pre-Op) given the night before, and the morning of the surgery. The control will receive two placebo drinks of equal volume. All participants will receive standard hospital care at the discretion of the clinical team. The primary outcome is the difference between groups in insulin resistance calculated by a glucose tolerance test administered pre-operatively and 24 hours postoperatively. Secondary endpoints will be changes in muscle carbohydrate metabolism (biopsy), mobility (Cumulative Ambulation Score) and subjective measures of tolerability. This is a small-scale pilot study, investigating the benefits and tolerability of carbohydrate loading in an emergency setting in a frail elderly group with known high morbidity and mortality. Positive findings will provide the basis for a larger scale study. Current Controlled Trials ISRCTN91109766 (7 April 2014); NRES ref: 13/EM/0214Trial Sponsor: University of Nottingham Ref.13036.
A screening-level modeling approach to estimate nitrogen ...
This paper presents a screening-level modeling approach that can be used to rapidly estimate nutrient loading and assess numerical nutrient standard exceedance risk of surface waters leading to potential classification as impaired for designated use. It can also be used to explore best management practice (BMP) implementation to reduce loading. The modeling framework uses a hybrid statistical and process based approach to estimate source of pollutants, their transport and decay in the terrestrial and aquatic parts of watersheds. The framework is developed in the ArcGIS environment and is based on the total maximum daily load (TMDL) balance model. Nitrogen (N) is currently addressed in the framework, referred to as WQM-TMDL-N. Loading for each catchment includes non-point sources (NPS) and point sources (PS). NPS loading is estimated using export coefficient or event mean concentration methods depending on the temporal scales, i.e., annual or daily. Loading from atmospheric deposition is also included. The probability of a nutrient load to exceed a target load is evaluated using probabilistic risk assessment, by including the uncertainty associated with export coefficients of various land uses. The computed risk data can be visualized as spatial maps which show the load exceedance probability for all stream segments. In an application of this modeling approach to the Tippecanoe River watershed in Indiana, USA, total nitrogen (TN) loading and risk of standard exce
Compression After Impact Testing of Sandwich Structures Using the Four Point Bend Test
NASA Technical Reports Server (NTRS)
Nettles, Alan T.; Gregory, Elizabeth; Jackson, Justin; Kenworthy, Devon
2008-01-01
For many composite laminated structures, the design is driven by data obtained from Compression after Impact (CAI) testing. There currently is no standard for CAI testing of sandwich structures although there is one for solid laminates of a certain thickness and lay-up configuration. Most sandwich CAI testing has followed the basic technique of this standard where the loaded ends are precision machined and placed between two platens and compressed until failure. If little or no damage is present during the compression tests, the loaded ends may need to be potted to prevent end brooming. By putting a sandwich beam in a four point bend configuration, the region between the inner supports is put under a compressive load and a sandwich laminate with damage can be tested in this manner without the need for precision machining. Also, specimens with no damage can be taken to failure so direct comparisons between damaged and undamaged strength can be made. Data is presented that demonstrates the four point bend CAI test and is compared with end loaded compression tests of the same sandwich structure.
Vibrations and structureborne noise in space station
NASA Technical Reports Server (NTRS)
Vaicaitis, R.
1985-01-01
Theoretical models were developed capable of predicting structural response and noise transmission to random point mechanical loads. Fiber reinforced composite and aluminum materials were considered. Cylindrical shells and circular plates were taken as typical representatives of structural components for space station habitability modules. Analytical formulations include double wall and single wall constructions. Pressurized and unpressurized models were considered. Parametric studies were conducted to determine the effect on structural response and noise transmission due to fiber orientation, point load location, damping in the core and the main load carrying structure, pressurization, interior acoustic absorption, etc. These analytical models could serve as preliminary tools for assessing noise related problems, for space station applications.
Method for thermoelectric cooler utilization using manufacturer's technical information
NASA Astrophysics Data System (ADS)
Ajiwiguna, Tri Ayodha; Nugroho, Rio; Ismardi, Abrar
2018-03-01
Thermoelectric cooler (TEC) module has been widely used for many applications. In this study, a procedure to use TEC module for specific requirement is developed based on manufacturer's technical data. For study case, the cooling system using TEC module is designed and tested to maintain 6.6 liter of water at 24 °C while surrounding temperature is 26 °C. First, cooling load estimation is performed empirically by observing the temperature change when cold water is inside the container. Second, the working temperature on hot side and cold side of TEC are determined. Third, the parameters of Seebeck coefficient, thermal resistance and electrical resistance are predicted by using information from the manufacturer. Fourth, the operating current is determined by the assumption the voltage across the TEC is 12V. Fifth, cooling capacity of TEC module is calculated by using energy balance equation of TEC. Sixth, the cooling load and cooling capacity are compared to determine the number of TEC module needed. The result of these calculations showed that one TEC module is enough for cooling system since the cooling load is 17.5 W while the cooling capacity is 18.87 W. From the experimental result, the set point temperature was achieved using one TEC module as predicted in calculations steps.
Variability of Jump Kinetics Related to Training Load in Elite Female Basketball.
Legg, Jan; Pyne, David B; Semple, Stuart; Ball, Nick
2017-11-04
The purpose of this study was to quantify changes in jump performance and variability in elite female basketballers. Junior and senior female representative basketball players ( n = 10) aged 18 ± 2 years participated in this study. Countermovement jump (CMJ) data was collected with a Gymaware™ optical encoder at pre-, mid-, and post-season time points across 10 weeks. Jump performance was maintained across the course of the full season (from pre to post). Concentric peak velocity, jump height, and dip showed the most stability from pre- to post-season, with the %CV ranging from 5.6⁻8.9%. In the period of the highest training load (mid-season), the variability of within-subject performance was reduced by approximately 2⁻4% in all measures except for jump height. Altered jump mechanics through a small (0.26 effect size) increase in dip were evident at mid-season, suggesting that CMJ analysis is useful for coaches to use as an in-season monitoring tool. The highest coefficient of variation (8⁻22%CV) in inter-set scores in all measures except eccentric peak velocity also occurred mid-season. It appears that in-season load not only impairs jump performance, but also movement variability in basketball players.
Design Spectrum Analysis in NASTRAN
NASA Technical Reports Server (NTRS)
Butler, T. G.
1984-01-01
The utility of Design Spectrum Analysis is to give a mode by mode characterization of the behavior of a design under a given loading. The theory of design spectrum is discussed after operations are explained. User instructions are taken up here in three parts: Transient Preface, Maximum Envelope Spectrum, and RMS Average Spectrum followed by a Summary Table. A single DMAP ALTER packet will provide for all parts of the design spectrum operations. The starting point for getting a modal break-down of the response to acceleration loading is the Modal Transient rigid format. After eigenvalue extraction, modal vectors need to be isolated in the full set of physical coordinates (P-sized as opposed to the D-sized vectors in RF 12). After integration for transient response the results are scanned over the solution time interval for the peak values and for the times that they occur. A module called SCAN was written to do this job, that organizes these maxima into a diagonal output matrix. The maximum amplifier in each mode is applied to the eigenvector of each mode which then reveals the maximum displacements, stresses, forces and boundary reactions that the structure will experience for a load history, mode by mode. The standard NASTRAN output processors have been modified for this task. It is required that modes be normalized to mass.
Rambling and trembling in response to body loading.
Tahayor, Behdad; Riley, Zachary A; Mahmoudian, Armaghan; Koceja, David M; Hong, Siang Lee
2012-04-01
Various studies have suggested that postural sway is controlled by at least two subsystems. Rambling-Trembling analysis is a widely accepted methodology to dissociate the signals generated by these two hypothetical subsystems. The core assumption of this method is based on the equilibrium point hypothesis which suggests that the central nervous system preserves upright standing by transiently shifting the center of pressure (COP) from one equilibrium point to another. The trajectory generated by this shifting is referred to as rambling and its difference from the original COP signal is referred to as trembling. In this study we showed that these two components of COP are differentially affected when standing with external loads. Using Detrended Fluctuation analysis, we compared the pattern of these two signals in different configurations of body loading. Our findings suggest that by applying an external load, the dynamics of the trembling component is altered independently of the area of postural sway and also independently of the rambling component. The dynamics of rambling changed only during the backloading condition in which the postural sway area also substantially increased. It can be suggested that during loaded standing, the trembling mechanism (which is suggested to be activated by peripheral mechanisms and reflexes) is altered without affecting the central influence on the shifts of the equilibrium point.
Ji, Haoran; Wang, Chengshan; Li, Peng; ...
2017-09-20
The integration of distributed generators (DGs) exacerbates the feeder power flow fluctuation and load unbalanced condition in active distribution networks (ADNs). The unbalanced feeder load causes inefficient use of network assets and network congestion during system operation. The flexible interconnection based on the multi-terminal soft open point (SOP) significantly benefits the operation of ADNs. The multi-terminal SOP, which is a controllable power electronic device installed to replace the normally open point, provides accurate active and reactive power flow control to enable the flexible connection of feeders. An enhanced SOCP-based method for feeder load balancing using the multi-terminal SOP is proposedmore » in this paper. Furthermore, by regulating the operation of the multi-terminal SOP, the proposed method can mitigate the unbalanced condition of feeder load and simultaneously reduce the power losses of ADNs. Then, the original non-convex model is converted into a second-order cone programming (SOCP) model using convex relaxation. In order to tighten the SOCP relaxation and improve the computation efficiency, an enhanced SOCP-based approach is developed to solve the proposed model. Finally, case studies are performed on the modified IEEE 33-node system to verify the effectiveness and efficiency of the proposed method.« less
Geometrically Nonlinear Finite Element Analysis of a Composite Space Reflector
NASA Technical Reports Server (NTRS)
Lee, Kee-Joo; Leet, Sung W.; Clark, Greg; Broduer, Steve (Technical Monitor)
2001-01-01
Lightweight aerospace structures, such as low areal density composite space reflectors, are highly flexible and may undergo large deflection under applied loading, especially during the launch phase. Accordingly, geometrically nonlinear analysis that takes into account the effect of finite rotation may be needed to determine the deformed shape for a clearance check and the stress and strain state to ensure structural integrity. In this study, deformation of the space reflector is determined under static conditions using a geometrically nonlinear solid shell finite element model. For the solid shell element formulation, the kinematics of deformation is described by six variables that are purely vector components. Because rotational angles are not used, this approach is free of the limitations of small angle increments. This also allows easy connections between substructures and large load increments with respect to the conventional shell formulation using rotational parameters. Geometrically nonlinear analyses were carried out for three cases of static point loads applied at selected points. A chart shows results for a case when the load is applied at the center point of the reflector dish. The computed results capture the nonlinear behavior of the composite reflector as the applied load increases. Also, they are in good agreement with the data obtained by experiments.
NASA Astrophysics Data System (ADS)
Petru, Jan; Dolezel, Jiri; Krivda, Vladislav
2017-09-01
In the past the excessive and oversized loads were realized on selected routes on roads that were adapted to ensure smooth passage of transport. Over the years, keeping the passages was abandoned and currently there are no earmarked routes which would be adapted for such type of transportation. The routes of excessive and oversized loads are currently planned to ensure passage of the vehicle through the critical points on the roads. Critical points are level and fly-over crossings of roads, bridges, toll gates, traffic signs and electrical and other lines. The article deals with the probability assessment of selected critical points of the route of the excessive load on the roads of 1st class, in relation to ensuring the passage through the roundabout. The bases for assessing the passage of the vehicle with excessive load through a roundabout are long-term results of video analyses of monitoring the movement of transports on similar intersections and determination of the theoretical probability model of vehicle movement at selected junctions. On the basis of a virtual simulation of the vehicle movement at crossroads and using MonteCarlo simulation method vehicles’ paths are analysed and the probability of exit of the vehicle outside the crossroad in given junctions is quantified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ji, Haoran; Wang, Chengshan; Li, Peng
The integration of distributed generators (DGs) exacerbates the feeder power flow fluctuation and load unbalanced condition in active distribution networks (ADNs). The unbalanced feeder load causes inefficient use of network assets and network congestion during system operation. The flexible interconnection based on the multi-terminal soft open point (SOP) significantly benefits the operation of ADNs. The multi-terminal SOP, which is a controllable power electronic device installed to replace the normally open point, provides accurate active and reactive power flow control to enable the flexible connection of feeders. An enhanced SOCP-based method for feeder load balancing using the multi-terminal SOP is proposedmore » in this paper. Furthermore, by regulating the operation of the multi-terminal SOP, the proposed method can mitigate the unbalanced condition of feeder load and simultaneously reduce the power losses of ADNs. Then, the original non-convex model is converted into a second-order cone programming (SOCP) model using convex relaxation. In order to tighten the SOCP relaxation and improve the computation efficiency, an enhanced SOCP-based approach is developed to solve the proposed model. Finally, case studies are performed on the modified IEEE 33-node system to verify the effectiveness and efficiency of the proposed method.« less
A potential method for lift evaluation from velocity field data
NASA Astrophysics Data System (ADS)
de Guyon-Crozier, Guillaume; Mulleners, Karen
2017-11-01
Computing forces from velocity field measurements is one of the challenges in experimental aerodynamics. This work focuses on low Reynolds flows, where the dynamics of the leading and trailing edge vortices play a major role in lift production. Recent developments in 2D potential flow theory, using discrete vortex models, have shown good results for unsteady wing motions. A method is presented to calculate lift from experimental velocity field data using a discrete vortex potential flow model. The model continuously adds new point vortices at leading and trailing edges whose circulations are set directly from vorticity measurements. Forces are computed using the unsteady Blasius equation and compared with measured loads.
Single-Event Transient Testing of Low Dropout PNP Series Linear Voltage Regulators
NASA Technical Reports Server (NTRS)
Adell, Philippe; Allen, Gregory
2013-01-01
As demand for high-speed, on-board, digital-processing integrated circuits on spacecraft increases (field-programmable gate arrays and digital signal processors in particular), the need for the next generation point-of-load (POL) regulator becomes a prominent design issue. Shrinking process nodes have resulted in core rails dropping to values close to 1.0 V, drastically reducing margin to standard switching converters or regulators that power digital ICs. The goal of this task is to perform SET characterization of several commercial POL converters, and provide a discussion of the impact of these results to state-of-the-art digital processing IC through laser and heavy ion testing
Multi-Agent Simulations of the Immune Response to Hiv during the Acute Stage of Infection
NASA Astrophysics Data System (ADS)
Walshe, R.; Ruskin, H. J.; Callaghan, A.
Results of multi-agent based simulations of the immune response to HIV during the acute phase of infection are presented here. The model successfully recreates the viral dynamics associated with the acute phase of infection, i.e., a rapid rise in viral load followed by a sharp decline to what is often referred to as a "set point", a result of T-cell response and emergence of HIV neutralizing antibodies. The results indicate that sufficient T Killer cell response is the key factor in controlling viral growth during this phase with antibody levels of critical importance only in the absence of a sufficient T Killer response.
Impact of HLA-DRB1 allele polymorphisms on control of HIV infection in a Peruvian MSM cohort.
Oriol-Tordera, B; Llano, A; Ganoza, C; Cate, S; Hildebrand, W; Sanchez, J; Calle, M L; Brander, C; Olvera, A
2017-10-01
Associations between HLA class II polymorphisms and HIV control were assessed in a Peruvian MSM cohort. Among 233 treatment naïve HIV+ individuals, DRB1*13:02 was linked to elevated viral loads (P = .044) while DRB1*12:01 showed significantly lower viral set points (P = .015) and restricted a dominant T cell response to HIV Gag p24 (P = .038). The present work contributes to a better knowledge of the Peruvian immunogenetics and supports the important role of HLA class II restricted T cells in HIV control. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Algorithms for Determining Physical Responses of Structures Under Load
NASA Technical Reports Server (NTRS)
Richards, W. Lance; Ko, William L.
2012-01-01
Ultra-efficient real-time structural monitoring algorithms have been developed to provide extensive information about the physical response of structures under load. These algorithms are driven by actual strain data to measure accurately local strains at multiple locations on the surface of a structure. Through a single point load calibration test, these structural strains are then used to calculate key physical properties of the structure at each measurement location. Such properties include the structure s flexural rigidity (the product of the structure's modulus of elasticity, and its moment of inertia) and the section modulus (the moment of inertia divided by the structure s half-depth). The resulting structural properties at each location can be used to determine the structure s bending moment, shear, and structural loads in real time while the structure is in service. The amount of structural information can be maximized through the use of highly multiplexed fiber Bragg grating technology using optical time domain reflectometry and optical frequency domain reflectometry, which can provide a local strain measurement every 10 mm on a single hair-sized optical fiber. Since local strain is used as input to the algorithms, this system serves multiple purposes of measuring strains and displacements, as well as determining structural bending moment, shear, and loads for assessing real-time structural health. The first step is to install a series of strain sensors on the structure s surface in such a way as to measure bending strains at desired locations. The next step is to perform a simple ground test calibration. For a beam of length l (see example), discretized into n sections and subjected to a tip load of P that places the beam in bending, the flexural rigidity of the beam can be experimentally determined at each measurement location x. The bending moment at each station can then be determined for any general set of loads applied during operation.
Wilkinson, S N; Dougall, C; Kinsey-Henderson, A E; Searle, R D; Ellis, R J; Bartley, R
2014-01-15
The use of river basin modelling to guide mitigation of non-point source pollution of wetlands, estuaries and coastal waters has become widespread. To assess and simulate the impacts of alternate land use or climate scenarios on river washload requires modelling techniques that represent sediment sources and transport at the time scales of system response. Building on the mean-annual SedNet model, we propose a new D-SedNet model which constructs daily budgets of fine sediment sources, transport and deposition for each link in a river network. Erosion rates (hillslope, gully and streambank erosion) and fine sediment sinks (floodplains and reservoirs) are disaggregated from mean annual rates based on daily rainfall and runoff. The model is evaluated in the Burdekin basin in tropical Australia, where policy targets have been set for reducing sediment and nutrient loads to the Great Barrier Reef (GBR) lagoon from grazing and cropping land. D-SedNet predicted annual loads with similar performance to that of a sediment rating curve calibrated to monitored suspended sediment concentrations. Relative to a 22-year reference load time series at the basin outlet derived from a dynamic general additive model based on monitoring data, D-SedNet had a median absolute error of 68% compared with 112% for the rating curve. RMS error was slightly higher for D-SedNet than for the rating curve due to large relative errors on small loads in several drought years. This accuracy is similar to existing agricultural system models used in arable or humid environments. Predicted river loads were sensitive to ground vegetation cover. We conclude that the river network sediment budget model provides some capacity for predicting load time-series independent of monitoring data in ungauged basins, and for evaluating the impact of land management on river sediment load time-series, which is challenging across large regions in data-poor environments. © 2013. Published by Elsevier B.V. All rights reserved.
Evaluation of Humidity Control Options in Hot-Humid Climate Homes (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2011-12-01
This technical highlight describes NREL research to analyze the indoor relative humidity in three home types in the hot-humid climate zone, and examine the impacts of various dehumidification equipment and controls. As the Building America program researches construction of homes that achieve greater source energy savings over typical mid-1990s construction, proper modeling of whole-house latent loads and operation of humidity control equipment has become a high priority. Long-term high relative humidity can cause health and durability problems in homes, particularly in a hot-humid climate. In this study, researchers at the National Renewable Energy Laboratory (NREL) used the latest EnergyPlus toolmore » equipped with the moisture capacitance model to analyze the indoor relative humidity in three home types: a Building America high-performance home; a mid-1990s reference home; and a 2006 International Energy Conservation Code (IECC)-compliant home in hot-humid climate zones. They examined the impacts of various dehumidification equipment and controls on the high-performance home where the dehumidification equipment energy use can become a much larger portion of whole-house energy consumption. The research included a number of simulated cases: thermostat reset, A/C with energy recovery ventilator, heat exchanger assisted A/C, A/C with condenser reheat, A/C with desiccant wheel dehumidifier, A/C with DX dehumidifier, A/C with energy recovery ventilator, and DX dehumidifier. Space relative humidity, thermal comfort, and whole-house source energy consumption were compared for indoor relative humidity set points of 50%, 55%, and 60%. The study revealed why similar trends of high humidity were observed in all three homes regardless of energy efficiency, and why humidity problems are not necessarily unique in the high-performance home. Thermal comfort analysis indicated that occupants are unlikely to notice indoor humidity problems. The study confirmed that supplemental dehumidification is needed to maintain space relative humidity (RH) below 60% in a hot-humid climate home. Researchers also concluded that while all the active dehumidification options included in the study successfully controlled space relative humidity excursions, the increase in whole-house energy consumption was much more sensitive to the humidity set point than the chosen technology option. In the high-performance home, supplemental dehumidification equipment results in a significant source energy consumption penalty at 50% RH set point (12.6%-22.4%) compared to the consumption at 60% RH set point (1.5%-2.7%). At 50% and 55% RH set points, A/C with desiccant wheel dehumidifier and A/C with ERV and high-efficiency DX dehumidifier stand out as the two cases resulting in the smallest increase of source energy consumption. At an RH set point of 60%, all explicit dehumidification technologies result in similar insignificant increases in source energy consumption and thus are equally competitive.« less
Lessons Learned from Stakeholder-Driven Modeling in the Western Lake Erie Basin
NASA Astrophysics Data System (ADS)
Muenich, R. L.; Read, J.; Vaccaro, L.; Kalcic, M. M.; Scavia, D.
2017-12-01
Lake Erie's history includes a great environmental success story. Recognizing the impact of high phosphorus loads from point sources, the United States and Canada 1972 Great Lakes Water Quality Agreement set load reduction targets to reduce algae blooms and hypoxia. The Lake responded quickly to those reductions and it was declared a success. However, since the mid-1990s, Lake Erie's algal blooms and hypoxia have returned, and this time with a dominant algae species that produces toxins. Return of the algal blooms and hypoxia is again driven by phosphorus loads, but this time a major source is the agriculturally-dominated Maumee River watershed that covers NW Ohio, NE Indiana, and SE Michigan, and the hypoxic extent has been shown to be driven by Maumee River loads plus those from the bi-national and multiple land-use St. Clair - Detroit River system. Stakeholders in the Lake Erie watershed have a long history of engagement with environmental policy, including modeling and monitoring efforts. This talk will focus on the application of interdisciplinary, stakeholder-driven modeling efforts aimed at understanding the primary phosphorus sources and potential pathways to reduce these sources and the resulting algal blooms and hypoxia in Lake Erie. We will discuss the challenges, such as engaging users with different goals, benefits to modeling, such as improvements in modeling data, and new research questions emerging from these modeling efforts that are driven by end-user needs.
Modelling of a Francis Turbine Runner Fatigue Failure Process Caused by Fluid-Structure Interaction
NASA Astrophysics Data System (ADS)
Lyutov, A.; Kryukov, A.; Cherny, S.; Chirkov, D.; Salienko, A.; Skorospelov, V.; Turuk, P.
2016-11-01
In the present paper considered is the problem of the numerical simulation of Francis turbine runner fatigue failure caused by fluid-structure interaction. The unsteady 3D flow is modeled simultaneously in the spiral chamber, each wicket gate and runner channels and in the draft tube using the Euler equations. Based on the unsteady runner loadings at each time step stresses in the whole runner are calculated using the elastic equilibrium equations solved with boundary element method. Set of static stress-strain states provides quasi-dynamics of runner cyclic loading. It is assumed that equivalent stresses in the runner are below the critical value after which irreversible plastic processes happen in the runner material. Therefore runner is subjected to the fatigue damage caused by high-cycle fatigue, in which the loads are generally low compared with the limit stress of the material. As a consequence, the stress state around the crack front can be fully characterized by linear elastic fracture mechanics. The place of runner cracking is determined as a point with maximal amplitude of stress oscillations. Stress pulsations amplitude is used to estimate the number of cycles until the moment of fatigue failure, number of loading cycles and oscillation frequency are used to calculate runner service time. Example of the real Francis runner which has encountered premature fatigue failure as a result of incorrect durability estimation is used to verify the developed numerical model.
On the structure of the set of coincidence points
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arutyunov, A V; Gel'man, B D
2015-03-31
We consider the set of coincidence points for two maps between metric spaces. Cardinality, metric and topological properties of the coincidence set are studied. We obtain conditions which guarantee that this set (a) consists of at least two points; (b) consists of at least n points; (c) contains a countable subset; (d) is uncountable. The results are applied to study the structure of the double point set and the fixed point set for multivalued contractions. Bibliography: 12 titles.
A study of the response of nonlinear springs
NASA Technical Reports Server (NTRS)
Hyer, M. W.; Knott, T. W.; Johnson, E. R.
1991-01-01
The various phases to developing a methodology for studying the response of a spring-reinforced arch subjected to a point load are discussed. The arch is simply supported at its ends with both the spring and the point load assumed to be at midspan. The spring is present to off-set the typical snap through behavior normally associated with arches, and to provide a structure that responds with constant resistance over a finite displacement. The various phases discussed consist of the following: (1) development of the closed-form solution for the shallow arch case; (2) development of a finite difference analysis to study (shallow) arches; and (3) development of a finite element analysis for studying more general shallow and nonshallow arches. The two numerical analyses rely on a continuation scheme to move the solution past limit points, and to move onto bifurcated paths, both characteristics being common to the arch problem. An eigenvalue method is used for a continuation scheme. The finite difference analysis is based on a mixed formulation (force and displacement variables) of the governing equations. The governing equations for the mixed formulation are in first order form, making the finite difference implementation convenient. However, the mixed formulation is not well-suited for the eigenvalue continuation scheme. This provided the motivation for the displacement based finite element analysis. Both the finite difference and the finite element analyses are compared with the closed form shallow arch solution. Agreement is excellent, except for the potential problems with the finite difference analysis and the continuation scheme. Agreement between the finite element analysis and another investigator's numerical analysis for deep arches is also good.
Evaluation of Strength Characteristics of Laterized Concrete with Corn Cob Ash (CCA) Blended Cement
NASA Astrophysics Data System (ADS)
Ikponmwosa, E. E.; Salau, M. A.; Kaigama, W. B.
2015-11-01
Agricultural wastes are dumped in landfills or left on land in which they constitute nuisance. This study presents the results of investigation of strength characteristics of reinforced laterized concrete beams with cement partially replaced with corn cob (agricultural wastes) ash (CCA). Laterized concrete specimen of 25% laterite and 75% sharp sand were made by blending cement with corn cob ash at 0 to 40% in steps of 10%. A concrete mix ratio of 1:2:4 was used to cast 54 cubes of 150×150×150mm size and 54 beams of dimension 750×150×150mm. The results show that the consistency and setting time of cement increased as the percentage replacement of cement with CCA increased while the workability and density of concrete decreased as the percentage of CCA increased. There was a decrease in compressive strength when laterite was introduced to the concrete from 25.04 to 22.96N/mm2 after 28 days and a continual reduction in strength when CCA was further added from 10% to 40% at steps of 10%. Generally, the beam specimens exhibited majorly shear failure with visible diagonal cracks extending from support points to the load points. The corresponding central deflection in beams, due to two points loading, increased as the laterite was added to the concrete mix but reduced and almost approaching that of the control as 10% CCA was added. The deflection then increased as the CCA content further increased to 20%, 30% and 40% in the mix. It was also noted that the deflection of all percentage replacement including 40% CCA is less than the standard recommended maximum deflection of the beam. The optimal flexural strength occurred with 10% CCA content.
Shock characterization of TOAD pins
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weirick, L.J.; Navarro, N.J.
1995-08-01
The purpose of this program was to characterize Time Of Arrival Detectors (TOAD) pins response to shock loading with respect to risetime, amplitude, repeatability and consistency. TOAD pins were subjected to impacts of 35 to 420 kilobars amplitude and approximately 1 ms pulse width to investigate the timing spread of four pins and the voltage output profile of the individual pins. Sets of pins were also aged at 45{degrees}, 60{degrees}, and 80{degrees}C for approximately nine weeks before shock testing at 315 kilobars impact stress. Four sets of pins were heated to 50.2{degrees}C (125{degrees}F) for approximately two hours and then impactedmore » at either 50 or 315 kilobars. Also, four sets of pins were aged at 60{degrees}C for nine weeks and then heated to 50.2{degrees}C before shock testing at 50 and 315 kilobars impact stress, respectively. Particle velocity measurements at the contact point between the stainless steel targets and TOAD pins were made using a Velocity Interferometer System for Any Reflector (VISAR) to monitor both the amplitude and profile of the shock waves.« less
Low Power Magnetic Bearing Design for High Speed Rotating Machinery
NASA Technical Reports Server (NTRS)
Allaire, P. E.; Maslen, E. H.; Humphris, R. R.; Sortore, C. K.; Studer, P. A.
1992-01-01
Magnetic suspension technology has advanced to the point of being able to offer a number of advantages to a variety of applications in the rotating machinery and aerospace fields. One strong advantage is the decrease in power consumption. The design and construction of a set of permanent magnet biased, actively controlled magnetic bearing for a flexible rotor are presented. Both permanent magnets and electromagnets are used in a configuration which effectively provides the necessary fluxes in the appropriate air gaps, while simultaneously keeping the undesirable destabilizing forces to a minimum. The design includes two radial bearings and a thrust bearing. The theoretical development behind the design is briefly discussed. Experimental performance results for a set of operating prototype bearings is presented. The results include measurements of load capacity, bearing stiffness and damping, and the dynamic response of the rotor. With few exceptions, the experimental results matched very well with the predicted performance. The power consumption of these bearings was found to be significantly reduced from that for a comparable set of all electromagnetic bearings.
Bruno Garza, J L; Young, J G
2015-01-01
Extended use of conventional computer input devices is associated with negative musculoskeletal outcomes. While many alternative designs have been proposed, it is unclear whether these devices reduce biomechanical loading and musculoskeletal outcomes. To review studies describing and evaluating the biomechanical loading and musculoskeletal outcomes associated with conventional and alternative input devices. Included studies evaluated biomechanical loading and/or musculoskeletal outcomes of users' distal or proximal upper extremity regions associated with the operation of alternative input devices (pointing devices, mice, other devices) that could be used in a desktop personal computing environment during typical office work. Some alternative pointing device designs (e.g. rollerbar) were consistently associated with decreased biomechanical loading while other designs had inconsistent results across studies. Most alternative keyboards evaluated in the literature reduce biomechanical loading and musculoskeletal outcomes. Studies of other input devices (e.g. touchscreen and gestural controls) were rare, however, those reported to date indicate that these devices are currently unsuitable as replacements for traditional devices. Alternative input devices that reduce biomechanical loading may make better choices for preventing or alleviating musculoskeletal outcomes during computer use, however, it is unclear whether many existing designs are effective.
Computational modeling of unsteady loads in tidal boundary layers
NASA Astrophysics Data System (ADS)
Alexander, Spencer R.
As ocean current turbines move from the design stage into production and installation, a better understanding of oceanic turbulent flows and localized loading is required to more accurately predict turbine performance and durability. In the present study, large eddy simulations (LES) are used to measure the unsteady loads and bending moments that would be experienced by an ocean current turbine placed in a tidal channel. The LES model captures currents due to winds, waves, thermal convection, and tides, thereby providing a high degree of physical realism. Probability density functions, means, and variances of unsteady loads are calculated, and further statistical measures of the turbulent environment are also examined, including vertical profiles of Reynolds stresses, two-point correlations, and velocity structure functions. The simulations show that waves and tidal velocity had the largest impact on the strength of off-axis turbine loads. By contrast, boundary layer stability and wind speeds were shown to have minimal impact on the strength of off- axis turbine loads. It is shown both analytically and using simulation results that either transverse velocity structure functions or two-point transverse velocity spatial correlations are good predictors of unsteady loading in tidal channels.
The Total Maximum Daily Load (TMDL) program, established by the Clean Water Act, is used to establish limits on loading of pollutants from point and nonpoint sources necessary to achieve water quality standards. One important use of a temperature TMDL is to allocate thermal loads...
Student Teacher Challenges: Using the Cognitive Load Theory as an Explanatory Lens
ERIC Educational Resources Information Center
Moos, Daniel C.; Pitton, Debra
2014-01-01
Cognitive load theory (CLT) can explain the challenges faced by student teachers. This study, guided by the CLT, included 26 pre-service teachers. Participants completed a cognitive load self-report questionnaire and were interviewed at two points during their student teaching. Results revealed that student teachers decreased mental effort related…
NASA Astrophysics Data System (ADS)
Frederickson, Lee Thomas
Much of combustion research focuses on reducing soot particulates in emissions. However, current research at San Diego State University (SDSU) Combustion and Solar Energy Laboratory (CSEL) is underway to develop a high temperature solar receiver which will utilize carbon nanoparticles as a solar absorption medium. To produce carbon nanoparticles for the small particle heat exchange receiver (SPHER), a lab-scale carbon particle generator (CPG) has been built and tested. The CPG is a heated ceramic tube reactor with a set point wall temperature of 1100-1300°C operating at 5-6 bar pressure. Natural gas and nitrogen are fed to the CPG where natural gas undergoes pyrolysis resulting in carbon particles. The gas-particle mixture is met downstream with dilution air and sent to the lab scale solar receiver. To predict soot yield and general trends in CPG performance, a model has been setup in Reaction Design CHEMKIN-PRO software. One of the primary goals of this research is to accurately measure particle properties. Mean particle diameter, size distribution, and index of refraction are calculated using Scanning Electron Microscopy (SEM) and a Diesel Particulate Scatterometer (DPS). Filter samples taken during experimentation are analyzed to obtain a particle size distribution with SEM images processed in ImageJ software. These results are compared with the DPS, which calculates the particle size distribution and the index of refraction from light scattering using Mie theory. For testing with the lab scale receiver, a particle diameter range of 200-500 nm is desired. Test conditions are varied to understand effects of operating parameters on particle size and the ability to obtain the size range. Analysis of particle loading is the other important metric for this research. Particle loading is measured downstream of the CPG outlet and dilution air mixing point. The air-particle mixture flows through an extinction tube where opacity of the mixture is measured with a 532 nm laser and detector. Beer's law is then used to calculate particle loading. The CPG needs to produce a certain particle loading for a corresponding receiver test. By obtaining the particle loading in the system, the reaction conversion to solid carbon in the CPG can be calculated to measure the efficiency of the CPG. To predict trends in reaction conversion and particle size from experimentation, the CHEMKIN-PRO computer model for the CPG is run for various flow rates and wall temperature profiles. These predictions were a reason for testing at higher wall set point temperatures. Based on these research goals, it was shown that the CPG consistently produces a mean particle diameter of 200-400 nm at the conditions tested, fitting perfectly inside the desired range. This led to successful lab scale SPHER testing which produced a 10-point efficiency increase and 150°C temperature difference with particles present. Also, at 3 g/s dilution air flow rate, an efficiency of 80% at an outlet temperature above 800°C was obtained. Promise was shown at higher CPG experimental temperatures to produce higher reaction conversion, both experimentally and in the model. However, based on wall temperature data taken during experimentation, it is apparent that the CPG needs to have multiple heating zones with separate temperature controllers in order to have an isothermal zone rather than a parabolic temperature profile. As for the computer model, it predicted much higher reaction conversion at higher temperature. The mass fraction of fuel in the inlet stream was shown to not affect conversion while increasing residence time led to increasing conversion. Particle size distribution in the model was far off and showed a bimodal distribution for one of the statistical methods. Using the results from experimentation and modeling, a preliminary CPG design is presented that will operate in a 5MWth receiver system.
Compensation for loads during arm movements using equilibrium-point control.
Gribble, P L; Ostry, D J
2000-12-01
A significant problem in motor control is how information about movement error is used to modify control signals to achieve desired performance. A potential source of movement error and one that is readily controllable experimentally relates to limb dynamics and associated movement-dependent loads. In this paper, we have used a position control model to examine changes to control signals for arm movements in the context of movement-dependent loads. In the model, based on the equilibrium-point hypothesis, equilibrium shifts are adjusted directly in proportion to the positional error between desired and actual movements. The model is used to simulate multi-joint movements in the presence of both "internal" loads due to joint interaction torques, and externally applied loads resulting from velocity-dependent force fields. In both cases it is shown that the model can achieve close correspondence to empirical data using a simple linear adaptation procedure. An important feature of the model is that it achieves compensation for loads during movement without the need for either coordinate transformations between positional error and associated corrective forces, or inverse dynamics calculations.
Lee, Ji-Hye; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra
2016-01-01
To evaluate the effect of implant coronal wall thickness on load-bearing capacity and screw joint stability. Experimental implants were customized after investigation of the thinnest coronal wall thickness of commercially available implant systems with a regular platform diameter. Implants with four coronal wall thicknesses (0.2, 0.3, 0.4, and 0.5 mm) were fabricated. Three sets of tests were performed. The first set was a failure test to evaluate load-bearing capacity and elastic limit. The second and third sets were cyclic and static loading tests. After abutment screw tightening of each implant, vertical cyclic loading of 250 N or static loading from 250 to 800 N was applied. Coronal diameter expansion, axial displacement, and removal torque values of the implants were compared. Repeated measures analysis of variance (ANOVA) was used for statistical analysis (α = .05). Implants with 0.2-mm coronal wall thickness demonstrated significantly low load-bearing capacity and elastic limit (both P < .05). These implants also showed significantly large coronal diameter expansion and axial displacement after screw tightening (both P < .05). Greater vertical load and thinner coronal wall thickness significantly increased coronal diameter expansion of the implant, axial displacement of the abutment, and removal torque loss of the abutment screw (all P < .05). Implant coronal wall thickness of 0.2 mm produces significantly inferior load-bearing capacity and screw joint stability.
A Load-Sharing Rip-Stop Fixation Construct for Arthroscopic Rotator Cuff Repair
Denard, Patrick J.; Burkhart, Stephen S.
2012-01-01
Despite advancements in arthroscopic rotator cuff repair techniques, achieving tendon-to-bone healing can be difficult in the setting of poor-quality tendon. Moreover, medial tendon tears or tears with lateral tendon loss may preclude standard techniques. Rip-stop suture configurations have been shown to improve load to failure compared with simple or mattress stitch patterns and may be particularly valuable in these settings. The purpose of this report is to describe a technical modification of a rip-stop rotator cuff repair that combines the advantages of a rip-stop suture (by providing resistance to tissue cutout) and a double row of load-sharing suture anchors (minimizing the load per anchor and therefore the load per suture within each anchor). PMID:23766972
Ready to Use Tissue Construct for Military Bone & Cartilage Trauma
2014-10-01
during nail introduction and reaming. In the present study, we examined the load - bearing capacity and optimal internal fixation of a bone/poly-ε...segmental defect, (a) axial loading via ball bearing , (b) torsional loading via square clamp allowing axial displacement, (c) three-point bending of tibia...knee joints by simulating loads seen during ambulation and knee range of motion. Our central hypothesis is that an anatomically and
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Yutian; Yang, Fei; Tolbert, Leon M.
With the increased cloud computing and digital information storage, the energy requirement of data centers keeps increasing. A high-voltage point of load (HV POL) with an input series output parallel structure is proposed to convert 400 to 1 VDC within a single stage to increase the power conversion efficiency. The symmetrical controlled half-bridge current doubler is selected as the converter topology in the HV POL. A load-dependent soft-switching method has been proposed with an auxiliary circuit that includes inductor, diode, and MOSFETs so that the hard-switching issue of typical symmetrical controlled half-bridge converters is resolved. The operation principles of themore » proposed soft-switching half-bridge current doubler have been analyzed in detail. Then, the necessity of adjusting the timing with the loading in the proposed method is analyzed based on losses, and a controller is designed to realize the load-dependent operation. A lossless RCD current sensing method is used to sense the output inductor current value in the proposed load-dependent operation. In conclusion, experimental efficiency of a hardware prototype is provided to show that the proposed method can increase the converter's efficiency in both heavy- and light-load conditions.« less
Cui, Yutian; Yang, Fei; Tolbert, Leon M.; ...
2016-06-14
With the increased cloud computing and digital information storage, the energy requirement of data centers keeps increasing. A high-voltage point of load (HV POL) with an input series output parallel structure is proposed to convert 400 to 1 VDC within a single stage to increase the power conversion efficiency. The symmetrical controlled half-bridge current doubler is selected as the converter topology in the HV POL. A load-dependent soft-switching method has been proposed with an auxiliary circuit that includes inductor, diode, and MOSFETs so that the hard-switching issue of typical symmetrical controlled half-bridge converters is resolved. The operation principles of themore » proposed soft-switching half-bridge current doubler have been analyzed in detail. Then, the necessity of adjusting the timing with the loading in the proposed method is analyzed based on losses, and a controller is designed to realize the load-dependent operation. A lossless RCD current sensing method is used to sense the output inductor current value in the proposed load-dependent operation. In conclusion, experimental efficiency of a hardware prototype is provided to show that the proposed method can increase the converter's efficiency in both heavy- and light-load conditions.« less
Dynamic parameters of three-point crutch gait in female patients after total hip arthroplasty.
Murawa, Michał; Dworak, Lechosław B; Kabaciński, Jarosław; Syczewska, Małgorzata; Rzepnicka, Agata
2016-01-01
Patient recovery after a surgical procedure depends, among other factors, on the amount of the body weight with which patient loads lower limb. Research studies report different results of the degree of body weight with which lower limb is loaded during three-point crutch gait. The aim of this study was to evaluate the level of the ground reaction forces (GRF) during crutch gait used by patients after total hip arthroplasty (THA) in the first week after discharge from the orthopaedic units. Ten female patients diagnosed with primary unilateral coxarthrosis participated in a single measurement session. In order to record kinematic and dynamic variables of this gait pattern motion analysis system was used together with two force plates. The static test of body weight distribution between lower limbs was performed on a dual-top stabilometric plate. The average peak values of loading on the operated (O) limb during mid stance and terminal stance of three-point crutch gait were 64.6% and 64.3% of body weight (BW), respectively, whereas in the case of the nonoperated (NO) limb 103.5%BW and 108.8%BW, respectively. The maximum loads on the crutches were significantly higher (by 9%BW) on the NO side as compared to the O side ( p < 0.05). During the static test, average values of body weight distribution on the O and NO limb were 36%BW and 64%BW, respectively. The patients showed surprisingly similar level of loading on the O limb. The weight bearing on the O limb was lower during static trial than during three-point crutch gait.
Using regression analysis to predict emergency patient volume at the Indianapolis 500 mile race.
Bowdish, G E; Cordell, W H; Bock, H C; Vukov, L F
1992-10-01
Emergency physicians often plan and provide on-site medical care for mass gatherings. Most of the mass gathering literature is descriptive. Only a few studies have looked at factors such as crowd size, event characteristics, or weather in predicting numbers and types of patients at mass gatherings. We used regression analysis to relate patient volume on Race Day at the Indianapolis Motor Speedway to weather conditions and race characteristics. Race Day weather data for the years 1983 to 1989 were obtained from the National Oceanic and Atmospheric Administration. Data regarding patients treated on 1983 to 1989 Race Days were obtained from the facility hospital (Hannah Emergency Medical Center) data base. Regression analysis was performed using weather factors and race characteristics as independent variables and number of patients seen as the dependent variable. Data from 1990 were used to test the validity of the model. There was a significant relationship between dew point (which is calculated from temperature and humidity) and patient load (P less than .01). Dew point, however, failed to predict patient load during the 1990 race. No relationships could be established between humidity, sunshine, wind, or race characteristics and number of patients. Although higher dew point was associated with higher patient load during the 1983 to 1989 races, dew point was a poor predictor of patient load during the 1990 race. Regression analysis may be useful in identifying relationships between event characteristics and patient load but is probably inadequate to explain the complexities of crowd behavior and too simplified to use as a prediction tool.
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. S. Schroeder; R. W. Youngblood
The Risk-Informed Safety Margin Characterization (RISMC) pathway of the Light Water Reactor Sustainability Program is developing simulation-based methods and tools for analyzing safety margin from a modern perspective. [1] There are multiple definitions of 'margin.' One class of definitions defines margin in terms of the distance between a point estimate of a given performance parameter (such as peak clad temperature), and a point-value acceptance criterion defined for that parameter (such as 2200 F). The present perspective on margin is that it relates to the probability of failure, and not just the distance between a nominal operating point and a criterion.more » In this work, margin is characterized through a probabilistic analysis of the 'loads' imposed on systems, structures, and components, and their 'capacity' to resist those loads without failing. Given the probabilistic load and capacity spectra, one can assess the probability that load exceeds capacity, leading to component failure. Within the project, we refer to a plot of these probabilistic spectra as 'the logo.' Refer to Figure 1 for a notional illustration. The implications of referring to 'the logo' are (1) RISMC is focused on being able to analyze loads and spectra probabilistically, and (2) calling it 'the logo' tacitly acknowledges that it is a highly simplified picture: meaningful analysis of a given component failure mode may require development of probabilistic spectra for multiple physical parameters, and in many practical cases, 'load' and 'capacity' will not vary independently.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chamana, Manohar; Mather, Barry A
A library of load variability classes is created to produce scalable synthetic data sets using historical high-speed raw data. These data are collected from distribution monitoring units connected at the secondary side of a distribution transformer. Because of the irregular patterns and large volume of historical high-speed data sets, the utilization of current load characterization and modeling techniques are challenging. Multi-resolution analysis techniques are applied to extract the necessary components and eliminate the unnecessary components from the historical high-speed raw data to create the library of classes, which are then utilized to create new synthetic load data sets. A validationmore » is performed to ensure that the synthesized data sets contain the same variability characteristics as the training data sets. The synthesized data sets are intended to be utilized in quasi-static time-series studies for distribution system planning studies on a granular scale, such as detailed PV interconnection studies.« less
Zhang, Sijia; Cao, Xuan; Stablow, Alec M.; Shenoy, Vivek B.; Winkelstein, Beth A.
2016-01-01
Excessive loading of ligaments can activate the neural afferents that innervate the collagenous tissue, leading to a host of pathologies including pain. An integrated experimental and modeling approach was used to define the responses of neurons and the surrounding collagen fibers to the ligamentous matrix loading and to begin to understand how macroscopic deformation is translated to neuronal loading and signaling. A neuron-collagen construct (NCC) developed to mimic innervation of collagenous tissue underwent tension to strains simulating nonpainful (8%) or painful ligament loading (16%). Both neuronal phosphorylation of extracellular signal-regulated kinase (ERK), which is related to neuroplasticity (R2 ≥ 0.041; p ≤ 0.0171) and neuronal aspect ratio (AR) (R2 ≥ 0.250; p < 0.0001), were significantly correlated with tissue-level strains. As NCC strains increased during a slowly applied loading (1%/s), a “switchlike” fiber realignment response was detected with collagen reorganization occurring only above a transition point of 11.3% strain. A finite-element based discrete fiber network (DFN) model predicted that at bulk strains above the transition point, heterogeneous fiber strains were both tensile and compressive and increased, with strains in some fibers along the loading direction exceeding the applied bulk strain. The transition point identified for changes in collagen fiber realignment was consistent with the measured strain threshold (11.7% with a 95% confidence interval of 10.2–13.4%) for elevating ERK phosphorylation after loading. As with collagen fiber realignment, the greatest degree of neuronal reorientation toward the loading direction was observed at the NCC distraction corresponding to painful loading. Because activation of neuronal ERK occurred only at strains that produced evident collagen fiber realignment, findings suggest that tissue strain-induced changes in the micromechanical environment, especially altered local collagen fiber kinematics, may be associated with mechanotransduction signaling in neurons. PMID:26549105
Zhao, Yifei; Zou, Xinqing; Liu, Qing; Yao, Yulong; Li, Yali; Wu, Xiaowei; Wang, Chenglong; Yu, Wenwen; Wang, Teng
2017-12-31
The water discharge and sediment load of rivers are changing substantially under the impacts of climate change and human activities, becoming a hot issue in hydro-environmental research. In this study, the water discharge and sediment load in the mainstream and seven tributaries of the Yangtze River were investigated by using long-term hydro-meteorological data from 1953 to 2013. The non-parametric Mann-Kendall test and double mass curve (DMC) were used to detect trends and abrupt change-points in water discharge and sediment load and to quantify the effects of climate change and human activities on water discharge and sediment load. The results are as follows: (1) the water discharge showed a non-significant decreasing trend at most stations except Hukou station. Among these, water discharge at Dongting Lake and the Min River basin shows a significant decreasing trend with average rates of -13.93×10 8 m 3 /year and -1.8×10 8 m 3 /year (P<0.05), respectively. However, the sediment load exhibited a significant decreasing trend in all tributaries of the Yangtze River. (2) No significant abrupt change-points were detected in the time series of water discharge for all hydrological stations. In contrast, significant abrupt change-points were detected in sediment load, most of these changes appeared in the late 1980s. (3) The water discharge was mainly influenced by precipitation in the Yangtze River basin, whereas sediment load was mainly affected by climate change and human activities; the relative contribution ratios of human activities were above 70% for the Yangtze River. (4) The decrease of sediment load has directly impacted the lower Yangtze River and the delta region. These results will provide a reference for better resource management in the Yangtze River Basin. Copyright © 2017 Elsevier B.V. All rights reserved.
Pathogen reduction co-benefits of nutrient best management practices
Wainger, Lisa A.; Barber, Mary C.
2016-01-01
Background Many of the practices currently underway to reduce nitrogen, phosphorus, and sediment loads entering the Chesapeake Bay have also been observed to support reduction of disease-causing pathogen loadings. We quantify how implementation of these practices, proposed to meet the nutrient and sediment caps prescribed by the Total Maximum Daily Load (TMDL), could reduce pathogen loadings and provide public health co-benefits within the Chesapeake Bay system. Methods We used published data on the pathogen reduction potential of management practices and baseline fecal coliform loadings estimated as part of prior modeling to estimate the reduction in pathogen loadings to the mainstem Potomac River and Chesapeake Bay attributable to practices implemented as part of the TMDL. We then compare the estimates with the baseline loadings of fecal coliform loadings to estimate the total pathogen reduction potential of the TMDL. Results We estimate that the TMDL practices have the potential to decrease disease-causing pathogen loads from all point and non-point sources to the mainstem Potomac River and the entire Chesapeake Bay watershed by 19% and 27%, respectively. These numbers are likely to be underestimates due to data limitations that forced us to omit some practices from analysis. Discussion Based on known impairments and disease incidence rates, we conclude that efforts to reduce nutrients may create substantial health co-benefits by improving the safety of water-contact recreation and seafood consumption. PMID:27904807
Pathogen reduction co-benefits of nutrient best management practices.
Richkus, Jennifer; Wainger, Lisa A; Barber, Mary C
2016-01-01
Many of the practices currently underway to reduce nitrogen, phosphorus, and sediment loads entering the Chesapeake Bay have also been observed to support reduction of disease-causing pathogen loadings. We quantify how implementation of these practices, proposed to meet the nutrient and sediment caps prescribed by the Total Maximum Daily Load (TMDL), could reduce pathogen loadings and provide public health co-benefits within the Chesapeake Bay system. We used published data on the pathogen reduction potential of management practices and baseline fecal coliform loadings estimated as part of prior modeling to estimate the reduction in pathogen loadings to the mainstem Potomac River and Chesapeake Bay attributable to practices implemented as part of the TMDL. We then compare the estimates with the baseline loadings of fecal coliform loadings to estimate the total pathogen reduction potential of the TMDL. We estimate that the TMDL practices have the potential to decrease disease-causing pathogen loads from all point and non-point sources to the mainstem Potomac River and the entire Chesapeake Bay watershed by 19% and 27%, respectively. These numbers are likely to be underestimates due to data limitations that forced us to omit some practices from analysis. Based on known impairments and disease incidence rates, we conclude that efforts to reduce nutrients may create substantial health co-benefits by improving the safety of water-contact recreation and seafood consumption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kulkarni, Rishikesh N.; Bakker, Astrid D.; Everts, Vincent
Highlights: Black-Right-Pointing-Pointer Osteocyte incubation with IL-1{beta} stimulated osteocyte-modulated osteoclastogenesis. Black-Right-Pointing-Pointer Conditioned medium from IL-1{beta}-treated osteocytes increased osteoclastogenesis. Black-Right-Pointing-Pointer IL-1{beta} upregulated RANKL and downregulated OPG gene expression by osteocytes. Black-Right-Pointing-Pointer CYR61 is upregulated in mechanically stimulated osteocytes. Black-Right-Pointing-Pointer Mechanical loading of osteocytes may abolish IL-1{beta}-induced osteoclastogenesis. -- Abstract: Inflammatory diseases such as rheumatoid arthritis are often accompanied by higher plasma and synovial fluid levels of interleukin-1{beta} (IL-1{beta}), and by increased bone resorption. Since osteocytes are known to regulate bone resorption in response to changes in mechanical stimuli, we investigated whether IL-1{beta} affects osteocyte-modulated osteoclastogenesis in the presence or absence of mechanicalmore » loading of osteocytes. MLO-Y4 osteocytes were pre-incubated with IL-1{beta} (0.1-1 ng/ml) for 24 h. Cells were either or not subjected to mechanical loading by 1 h pulsating fluid flow (PFF; 0.7 {+-} 0.3 Pa, 5 Hz) in the presence of IL-1{beta} (0.1-1 ng/ml). Conditioned medium was collected after 1 h PFF or static cultures. Subsequently mouse bone marrow cells were seeded on top of the IL-1{beta}-treated osteocytes to determine osteoclastogenesis. Conditioned medium from mechanically loaded or static IL-1{beta}-treated osteocytes was added to co-cultures of untreated osteocytes and mouse bone marrow cells. Gene expression of cysteine-rich protein 61 (CYR61/CCN1), receptor activator of nuclear factor kappa-B ligand (RANKL), and osteoprotegerin (OPG) by osteocytes was determined immediately after PFF. Incubation of osteocytes with IL-1{beta}, as well as conditioned medium from static IL-1{beta}-treated osteocytes increased the formation of osteoclasts. However, conditioned medium from mechanically loaded IL-1{beta}-treated osteocytes prevented osteoclast formation. Incubation with IL-1{beta} upregulated RANKL and downregulated OPG gene expression by static osteocytes. PFF upregulated CYR61, RANKL, and OPG gene expression by osteocytes. Our results suggest that IL-1{beta} increases osteocyte-modulated osteoclastogenesis, and that mechanical loading of osteocytes may abolish IL-1{beta}-induced osteoclastogenesis.« less
NASA Technical Reports Server (NTRS)
Edwards, T. R. (Inventor)
1985-01-01
Apparatus for doubling the data density rate of an analog to digital converter or doubling the data density storage capacity of a memory deviced is discussed. An interstitial data point midway between adjacent data points in a data stream having an even number of equal interval data points is generated by applying a set of predetermined one-dimensional convolute integer coefficients which can include a set of multiplier coefficients and a normalizer coefficient. Interpolator means apply the coefficients to the data points by weighting equally on each side of the center of the even number of equal interval data points to obtain an interstital point value at the center of the data points. A one-dimensional output data set, which is twice as dense as a one-dimensional equal interval input data set, can be generated where the output data set includes interstitial points interdigitated between adjacent data points in the input data set. The method for generating the set of interstital points is a weighted, nearest-neighbor, non-recursive, moving, smoothing averaging technique, equivalent to applying a polynomial regression calculation to the data set.
Ivahnenko, Tamara I.
2017-12-07
Changes in municipal and industrial point-source discharges over time have been an important factor affecting nutrient trends in many of the Nation’s streams and rivers. This report documents how three U.S. Environmental Protection Agency (EPA) national datasets—the Permit Compliance System, the Integrated Compliance Information System, and the Clean Watersheds Needs Survey—were evaluated for use in the U.S. Geological Survey National Water-Quality Assessment project to assess the causes of nutrient trends. This report also describes how a database of total nitrogen load and total phosphorous load was generated for select wastewater treatment facilities in the United States based on information reported in the EPA Clean Watersheds Needs Survey. Nutrient loads were calculated for the years 1978, 1980, 1982, 1984, 1986, 1988, 1990, 1992, 1996, 2000, 2004, 2008, and 2012 based on average nitrogen and phosphorous concentrations for reported treatment levels and on annual reported flow values.The EPA Permit Compliance System (PCS) and Integrated Compliance Information System (ICIS), which monitor point-source facility discharges, together are the Nation’s most spatially comprehensive dataset for nutrients released to surface waters. However, datasets for many individual facilities are incomplete, the PCS/ICIS historical data date back only to 1989, and historical data are available for only a limited number of facilities. Additionally, inconsistencies in facility reporting make it difficult to track or identify changes in nutrient discharges over time. Previous efforts made by the U.S. Geological Survey to “fill in” gaps in the PCS/ICIS data were based on statistical methods—missing data were filled in through the use of a statistical model based on the Standard Industrial Classification code, size, and flow class of the facility and on seasonal nutrient discharges of similar facilities. This approach was used to estimate point-source loads for a single point in time; it was not evaluated for use in generating a consistent data series over time.Another national EPA dataset that is available is the Clean Watersheds Needs Survey (CWNS), conducted every 4 years beginning 1973. The CWNS is an assessment of the capital needs of wastewater facilities to meet the water-quality goals set in the Clean Water Act. Data collected about these facilities include location and contact information for the facilities; population served; flow and treatment level of the facility; estimated capital needs to upgrade, repair, or improve facilities for water quality; and nonpoint-source best management practices.Total nitrogen and total phosphorous load calculations for each of the CWNS years were based on treatment level information and average annual outflow (in million gallons per day) from each of the facilities that had reported it. Treatment levels categories (such as Primary, Secondary, or Advanced) were substituted with average total nitrogen and total phosphorous concentrations for each treatment level based on those reported in literature. The CWNS dataset, like the PCS/ICIS dataset, has years where facilities did not report either a treatment level or an annual average outflow, or both. To fill in the data gaps, simple linear assumptions were made based on each facility’s responses to the survey in years bracketing the data gap or immediately before or after the data gap if open ended. Treatment level and flow data unique to each facility were used to complete the CWNS dataset for that facility.
Programs To Optimize Spacecraft And Aircraft Trajectories
NASA Technical Reports Server (NTRS)
Brauer, G. L.; Petersen, F. M.; Cornick, D.E.; Stevenson, R.; Olson, D. W.
1994-01-01
POST/6D POST is set of two computer programs providing ability to target and optimize trajectories of powered or unpowered spacecraft or aircraft operating at or near rotating planet. POST treats point-mass, three-degree-of-freedom case. 6D POST treats more-general rigid-body, six-degree-of-freedom (with point masses) case. Used to solve variety of performance, guidance, and flight-control problems for atmospheric and orbital vehicles. Applications include computation of performance or capability of vehicle in ascent, or orbit, and during entry into atmosphere, simulation and analysis of guidance and flight-control systems, dispersion-type analyses and analyses of loads, general-purpose six-degree-of-freedom simulation of controlled and uncontrolled vehicles, and validation of performance in six degrees of freedom. Written in FORTRAN 77 and C language. Two machine versions available: one for SUN-series computers running SunOS(TM) (LAR-14871) and one for Silicon Graphics IRIS computers running IRIX(TM) operating system (LAR-14869).
Ravald, L; Fornstedt, T
2001-01-26
The bi-Langmuir equation has recently been proven essential to describe chiral chromatographic surfaces and we therefore investigated the accuracy of the elution by characteristic points method (ECP) for estimation of bi-Langmuir isotherm parameters. The ECP calculations was done on elution profiles generated by the equilibrium-dispersive model of chromatography for five different sets of bi-Langmuir parameters. The ECP method generates two different errors; (i) the error of the ECP calculated isotherm and (ii) the model error of the fitting to the ECP isotherm. Both errors decreased with increasing column efficiency. Moreover, the model error was strongly affected by the weight of the bi-Langmuir function fitted. For some bi-Langmuir compositions the error of the ECP calculated isotherm is too large even at high column efficiencies. Guidelines will be given on surface types to be avoided and on column efficiencies and loading factors required for adequate parameter estimations with ECP.
NASA Astrophysics Data System (ADS)
Poirier, Vincent
Mesh deformation schemes play an important role in numerical aerodynamic optimization. As the aerodynamic shape changes, the computational mesh must adapt to conform to the deformed geometry. In this work, an extension to an existing fast and robust Radial Basis Function (RBF) mesh movement scheme is presented. Using a reduced set of surface points to define the mesh deformation increases the efficiency of the RBF method; however, at the cost of introducing errors into the parameterization by not recovering the exact displacement of all surface points. A secondary mesh movement is implemented, within an adjoint-based optimization framework, to eliminate these errors. The proposed scheme is tested within a 3D Euler flow by reducing the pressure drag while maintaining lift of a wing-body configured Boeing-747 and an Onera-M6 wing. As well, an inverse pressure design is executed on the Onera-M6 wing and an inverse span loading case is presented for a wing-body configured DLR-F6 aircraft.
Grinding efficiency of abutment tooth with both dentin and core composite resin on axial plane.
Miho, Otoaki; Sato, Toru; Matsukubo, Takashi
2015-01-01
The purpose of this study was to evaluate grinding efficiency in abutment teeth comprising both dentin and core composite resin in the axial plane. Grinding was performed over 5 runs at two loads (0.5 or 0.25 N) and two feed rates (1 or 2 mm/sec). The grinding surface was observed with a 3-D laser microscope. Tomographic images of the grinding surfaces captured perpendicular to the feed direction were also analyzed. Using a non-ground surface as a reference, areas comprising only dentin, both dentin and core composite resin, or only core composite resin were analyzed to determine the angle of the grinding surface. Composite resins were subjected to the Vickers hardness test and scanning electron microscopy. Data were statistically analyzed using a one-way analysis of variance and multiple comparison tests. Multiple regression analysis was performed for load, feed rate, and Vickers hardness of the build-up material depending on number of runs. When grinding was performed at a constant load and feed rate, a greater grinding angle was observed in areas comprising both dentin and composite resin or only composite resin than in areas consisting of dentin alone. A correlation was found between machinability and load or feed rate in areas comprising both dentin and composite resin or composite resin alone, with a particularly high correlation being observed between machinability and load. These results suggest that great caution should be exercised in a clinical setting when the boundary between the dentin and composite resin is to be ground, as the angle of the grinding surface changes when the rotating diamond point begins grinding the composite resin.
Zhang, Tao; Yang, Xiaojun
2013-01-01
Watershed-wide land-cover proportions can be used to predict the in-stream non-point source pollutant loadings through regression modeling. However, the model performance can vary greatly across different study sites and among various watersheds. Existing literature has shown that this type of regression modeling tends to perform better for large watersheds than for small ones, and that such a performance variation has been largely linked with different interwatershed landscape heterogeneity levels. The purpose of this study is to further examine the previously mentioned empirical observation based on a set of watersheds in the northern part of Georgia (USA) to explore the underlying causes of the variation in model performance. Through the combined use of the neutral landscape modeling approach and a spatially explicit nutrient loading model, we tested whether the regression model performance variation over the watershed groups ranging in size is due to the different watershed landscape heterogeneity levels. We adopted three neutral landscape modeling criteria that were tied with different similarity levels in watershed landscape properties and used the nutrient loading model to estimate the nitrogen loads for these neutral watersheds. Then we compared the regression model performance for the real and neutral landscape scenarios, respectively. We found that watershed size can affect the regression model performance both directly and indirectly. Along with the indirect effect through interwatershed heterogeneity, watershed size can directly affect the model performance over the watersheds varying in size. We also found that the regression model performance can be more significantly affected by other physiographic properties shaping nitrogen delivery effectiveness than the watershed land-cover heterogeneity. This study contrasts with many existing studies because it goes beyond hypothesis formulation based on empirical observations and into hypothesis testing to explore the fundamental mechanism.
Tefas, Lucia Ruxandra; Sylvester, Bianca; Tomuta, Ioan; Sesarman, Alina; Licarete, Emilia; Banciu, Manuela; Porfire, Alina
2017-01-01
The aim of this work was to use the quality-by-design (QbD) approach in the development of long-circulating liposomes co-loaded with curcumin (CUR) and doxorubicin (DOX) and to evaluate the cytotoxic potential of these liposomes in vitro using C26 murine colon carcinoma cell line. Based on a risk assessment, six parameters, namely the phospholipid, CUR and DOX concentrations, the phospholipid:cholesterol molar ratio, the temperature during the evaporation and hydration steps and the pH of the phosphate buffer, were identified as potential risk factors for the quality of the final product. The influence of these variables on the critical quality attributes of the co-loaded liposomal CUR and DOX was investigated: particle size, zeta potential, drug loading and entrapment efficiency. For this, a 2 6-2 factorial design was employed to establish a proper regression model and to generate the contour plots for the responses. The obtained data served to establish the design space for which different combinations of variables yielded liposomes with characteristics within predefined specifications. The validation of the model was carried out by preparing two liposomal formulations corresponding to the robust set point from within the design space and one outside the design space and calculating the percentage bias between the predicted and actual experimental results. The in vitro antiproliferative test showed that at higher CUR concentrations, the liposomes co-encapsulating CUR and DOX had a greater cytotoxic effect than DOX-loaded liposomes. Overall, this study showed that QbD is a useful instrument for controlling and optimizing the manufacturing process of liposomes co-loaded with CUR and DOX and that this nanoparticulate system possesses a great potential for use in colon cancer therapy.
Point-of-Care Viral Load Testing for Sub-Saharan Africa: Informing a Target Product Profile.
Phillips, Andrew N; Cambiano, Valentina; Nakagawa, Fumiyo; Ford, Deborah; Apollo, Tsitsi; Murungu, Joseph; Rousseau, Christine; Garnett, Geoff; Ehrenkranz, Peter; Bansi-Matharu, Loveleen; Vojnov, Lara; Katz, Zachary; Peeling, Rosanna; Revill, Paul
2016-09-01
Point-of-care viral load tests are being developed to monitor patients on antiretroviral therapy (ART) in sub-Saharan Africa. Test design involves trade-offs between test attributes, including accuracy, complexity, robustness, and cost. We used a model of the human immunodeficiency virus epidemic and ART program in Zimbabwe and found that the attributes of a viral load testing approach that are most influential for cost effectiveness are avoidance of a high proportion of failed tests or results not received, use of an approach that best facilitates retention on ART, and the ability to facilitate greater use of differentiated care, including through expanding coverage of testing availability.
Point-of-Care Viral Load Testing for Sub-Saharan Africa: Informing a Target Product Profile
Phillips, Andrew N.; Cambiano, Valentina; Nakagawa, Fumiyo; Ford, Deborah; Apollo, Tsitsi; Murungu, Joseph; Rousseau, Christine; Garnett, Geoff; Ehrenkranz, Peter; Bansi-Matharu, Loveleen; Vojnov, Lara; Katz, Zachary; Peeling, Rosanna; Revill, Paul
2016-01-01
Point-of-care viral load tests are being developed to monitor patients on antiretroviral therapy (ART) in sub-Saharan Africa. Test design involves trade-offs between test attributes, including accuracy, complexity, robustness, and cost. We used a model of the human immunodeficiency virus epidemic and ART program in Zimbabwe and found that the attributes of a viral load testing approach that are most influential for cost effectiveness are avoidance of a high proportion of failed tests or results not received, use of an approach that best facilitates retention on ART, and the ability to facilitate greater use of differentiated care, including through expanding coverage of testing availability. PMID:27704016
Load cell having strain gauges of arbitrary location
Spletzer, Barry [Albuquerque, NM
2007-03-13
A load cell utilizes a plurality of strain gauges mounted upon the load cell body such that there are six independent load-strain relations. Load is determined by applying the inverse of a load-strain sensitivity matrix to a measured strain vector. The sensitivity matrix is determined by performing a multivariate regression technique on a set of known loads correlated to the resulting strains. Temperature compensation is achieved by configuring the strain gauges as co-located orthogonal pairs.
Power management of remote microgrids considering battery lifetime
NASA Astrophysics Data System (ADS)
Chalise, Santosh
Currently, 20% (1.3 billion) of the world's population still lacks access to electricity and many live in remote areas where connection to the grid is not economical or practical. Remote microgrids could be the solution to the problem because they are designed to provide power for small communities within clearly defined electrical boundaries. Reducing the cost of electricity for remote microgrids can help to increase access to electricity for populations in remote areas and developing countries. The integration of renewable energy and batteries in diesel based microgrids has shown to be effective in reducing fuel consumption. However, the operational cost remains high due to the low lifetime of batteries, which are heavily used to improve the system's efficiency. In microgrid operation, a battery can act as a source to augment the generator or a load to ensure full load operation. In addition, a battery increases the utilization of PV by storing extra energy. However, the battery has a limited energy throughput. Therefore, it is required to provide balance between fuel consumption and battery lifetime throughput in order to lower the cost of operation. This work presents a two-layer power management system for remote microgrids. First layer is day ahead scheduling, where power set points of dispatchable resources were calculated. Second layer is real time dispatch, where schedule set points from the first layer are accepted and resources are dispatched accordingly. A novel scheduling algorithm is proposed for a dispatch layer, which considers the battery lifetime in optimization and is expected to reduce the operational cost of the microgrid. This method is based on a goal programming approach which has the fuel and the battery wear cost as two objectives to achieve. The effectiveness of this method was evaluated through a simulation study of a PV-diesel hybrid microgrid using deterministic and stochastic approach of optimization.
14 CFR 25.519 - Jacking and tie-down provisions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... structure must be designed for a vertical load of 1.33 times the vertical static reaction at each jacking point acting singly and in combination with a horizontal load of 0.33 times the vertical static reaction...: (i) The airplane structure must be designed for a vertical load of 1.33 times the vertical reaction...
14 CFR 25.519 - Jacking and tie-down provisions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... structure must be designed for a vertical load of 1.33 times the vertical static reaction at each jacking point acting singly and in combination with a horizontal load of 0.33 times the vertical static reaction...: (i) The airplane structure must be designed for a vertical load of 1.33 times the vertical reaction...
14 CFR 25.519 - Jacking and tie-down provisions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... structure must be designed for a vertical load of 1.33 times the vertical static reaction at each jacking point acting singly and in combination with a horizontal load of 0.33 times the vertical static reaction...: (i) The airplane structure must be designed for a vertical load of 1.33 times the vertical reaction...
14 CFR 25.519 - Jacking and tie-down provisions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... structure must be designed for a vertical load of 1.33 times the vertical static reaction at each jacking point acting singly and in combination with a horizontal load of 0.33 times the vertical static reaction...: (i) The airplane structure must be designed for a vertical load of 1.33 times the vertical reaction...
14 CFR 25.519 - Jacking and tie-down provisions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... structure must be designed for a vertical load of 1.33 times the vertical static reaction at each jacking point acting singly and in combination with a horizontal load of 0.33 times the vertical static reaction...: (i) The airplane structure must be designed for a vertical load of 1.33 times the vertical reaction...
2011-03-20
tive humidity of 34%. Dynamic experiments on the Kolsky bar were conducted at a loading rate of approximately 5x106 MPa/s. Fractography was conducted...pulse loading technique was adopted to ensure that the glass specimen was loaded only once and therefore in the fractography point of view, the
Interactive model evaluation tool based on IPython notebook
NASA Astrophysics Data System (ADS)
Balemans, Sophie; Van Hoey, Stijn; Nopens, Ingmar; Seuntjes, Piet
2015-04-01
In hydrological modelling, some kind of parameter optimization is mostly performed. This can be the selection of a single best parameter set, a split in behavioural and non-behavioural parameter sets based on a selected threshold or a posterior parameter distribution derived with a formal Bayesian approach. The selection of the criterion to measure the goodness of fit (likelihood or any objective function) is an essential step in all of these methodologies and will affect the final selected parameter subset. Moreover, the discriminative power of the objective function is also dependent from the time period used. In practice, the optimization process is an iterative procedure. As such, in the course of the modelling process, an increasing amount of simulations is performed. However, the information carried by these simulation outputs is not always fully exploited. In this respect, we developed and present an interactive environment that enables the user to intuitively evaluate the model performance. The aim is to explore the parameter space graphically and to visualize the impact of the selected objective function on model behaviour. First, a set of model simulation results is loaded along with the corresponding parameter sets and a data set of the same variable as the model outcome (mostly discharge). The ranges of the loaded parameter sets define the parameter space. A selection of the two parameters visualised can be made by the user. Furthermore, an objective function and a time period of interest need to be selected. Based on this information, a two-dimensional parameter response surface is created, which actually just shows a scatter plot of the parameter combinations and assigns a color scale corresponding with the goodness of fit of each parameter combination. Finally, a slider is available to change the color mapping of the points. Actually, the slider provides a threshold to exclude non behaviour parameter sets and the color scale is only attributed to the remaining parameter sets. As such, by interactively changing the settings and interpreting the graph, the user gains insight in the model structural behaviour. Moreover, a more deliberate choice of objective function and periods of high information content can be identified. The environment is written in an IPython notebook and uses the available interactive functions provided by the IPython community. As such, the power of the IPython notebook as a development environment for scientific computing is illustrated (Shen, 2014).
NASA Astrophysics Data System (ADS)
Saleh, D.; Domagalski, J. L.
2012-12-01
Sources and factors affecting the transport of total nitrogen are being evaluated for a study area that covers most of California and some areas in Oregon and Nevada, by using the SPARROW model (SPAtially Referenced Regression On Watershed attributes) developed by the U.S. Geological Survey. Mass loads of total nitrogen calculated for monitoring sites at stream gauging stations are regressed against land-use factors affecting nitrogen transport, including fertilizer use, recharge, atmospheric deposition, stream characteristics, and other factors to understand how total nitrogen is transported under average conditions. SPARROW models have been used successfully in other parts of the country to understand how nutrients are transported, and how management strategies can be formulated, such as with Total Maximum Daily Load (TMDL) assessments. Fertilizer use, atmospheric deposition, and climatic data were obtained for 2002, and loads for that year were calculated for monitored streams and point sources (mostly from wastewater treatment plants). The stream loads were calculated by using the adjusted maximum likelihood estimation method (AMLE). River discharge and nitrogen concentrations were de-trended in these calculations in order eliminate the effect of temporal changes on stream load. Effluent discharge information as well as total nitrogen concentrations from point sources were obtained from USEPA databases and from facility records. The model indicates that atmospheric deposition and fertilizer use account for a large percentage of the total nitrogen load in many of the larger watersheds throughout the study area. Point sources, on the other hand, are generally localized around large cities, are considered insignificant sources, and account for a small percentage of the total nitrogen loads throughout the study area.
NASA Astrophysics Data System (ADS)
Ahmed, J.; Constantine, J. A.; Hales, T. C.
2017-12-01
Meandering channels provide a conduit through which sediment and water is routed from the uplands to the sea. Alluvial material is periodically stored and transported through the channel network as permitted by the prevailing hydrologic conditions. The lowlands are typically characterised by accumulations of sediment attached to the inner banks of meander bends (point bars). These bedforms have been identified as important for facilitating a link between in-stream sediment supplies and channel dynamism. A 2D curvilinear hydrodynamic model (MIKE 21C) was used to perform a number of experiments in which the sediment load was adjusted to investigate how changes in alluvial material fluxes affect the development of point bars and the resultant patterns of bank erosion. A doubling of the sediment load caused a longitudinal increase in the bar in the upstream direction and caused a coeval doubling of the transverse channel slope at the meander apex. The upstream growth of the point bar was accompanied by an increase in length over which lateral migration took place at the outer bank. The magnitude of outer bank erosion was 9-times greater for the high-sediment simulation. These results suggest that enhanced sediment loads (potentially the result of changes in land use or climate) can trigger greater rates of bank erosion and channel change through the sequestration of alluvial material on point bars, which encourage high-velocity fluid deflection towards the outer bank of the meander. This controls riparian habitat development and exchanges of sediment and nutrients across the channel-floodplain interface.
Security Policies for Mitigating the Risk of Load Altering Attacks on Smart Grid Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryutov, Tatyana; AlMajali, Anas; Neuman, Clifford
2015-04-01
While demand response programs implement energy efficiency and power quality objectives, they bring potential security threats to the Smart Grid. The ability to influence load in a system enables attackers to cause system failures and impacts the quality and integrity of power delivered to customers. This paper presents a security mechanism to monitor and control load according to a set of security policies during normal system operation. The mechanism monitors, detects, and responds to load altering attacks. We examined the security requirements of Smart Grid stakeholders and constructed a set of load control policies enforced by the mechanism. We implementedmore » a proof of concept prototype and tested it using the simulation environment. By enforcing the proposed policies in this prototype, the system is maintained in a safe state in the presence of load drop attacks.« less
Burgess, Darren J
2017-04-01
Research describing load-monitoring techniques for team sport is plentiful. Much of this research is conducted retrospectively and typically involves recreational or semielite teams. Load-monitoring research conducted on professional team sports is largely observational. Challenges exist for the practitioner in implementing peer-reviewed research into the applied setting. These challenges include match scheduling, player adherence, manager/coach buy-in, sport traditions, and staff availability. External-load monitoring often attracts questions surrounding technology reliability and validity, while internal-load monitoring makes some assumptions about player adherence, as well as having some uncertainty around the impact these measures have on player performance This commentary outlines examples of load-monitoring research, discusses the issues associated with the application of this research in an elite team-sport setting, and suggests practical adjustments to the existing research where necessary.
NASA Astrophysics Data System (ADS)
Dupas, Rémi; Tittel, Jörg; Jordan, Phil; Musolff, Andreas; Rode, Michael
2018-05-01
A common assumption in phosphorus (P) load apportionment studies is that P loads in rivers consist of flow independent point source emissions (mainly from domestic and industrial origins) and flow dependent diffuse source emissions (mainly from agricultural origin). Hence, rivers dominated by point sources will exhibit highest P concentration during low-flow, when flow dilution capacity is minimal, whereas rivers dominated by diffuse sources will exhibit highest P concentration during high-flow, when land-to-river hydrological connectivity is maximal. Here, we show that Soluble Reactive P (SRP) concentrations in three forested catchments free of point sources exhibited seasonal maxima during the summer low-flow period, i.e. a pattern expected in point source dominated areas. A load apportionment model (LAM) is used to show how point sources contribution may have been overestimated in previous studies, because of a biogeochemical process mimicking a point source signal. Almost twenty-two years (March 1995-September 2016) of monthly monitoring data of SRP, dissolved iron (Fe) and nitrate-N (NO3) were used to investigate the underlying mechanisms: SRP and Fe exhibited similar seasonal patterns and opposite to that of NO3. We hypothesise that Fe oxyhydroxide reductive dissolution might be the cause of SRP release during the summer period, and that NO3 might act as a redox buffer, controlling the seasonality of SRP release. We conclude that LAMs may overestimate the contribution of P point sources, especially during the summer low-flow period, when eutrophication risk is maximal.
Vibroacoustic Characterization of a New Hybrid Wing-Body Fuselage Concept
NASA Technical Reports Server (NTRS)
Allen, Albert R.; Przekop, Adam
2012-01-01
A lighter, more robust airframe design is required to withstand the loading inherent to next generation non cylindrical commercial airliners. The Pultruded Rod Stitched Efficient Unitized Structure concept, a highly integrated composite design involving a stitched and co-cured substructure, has been developed to meet such requirements. While this structure has been shown to meet the demanding out-of-plane loading requirements of the flat-sided pressurized cabin design, there are concerns that the stiff co-cured details will result in relatively high acoustic radiation efficiencies at frequencies well below the thin skin acoustic coincidence frequency. To address this concern and establish a set of baseline vibroacoustic characteristics, a representative test panel was fabricated and a suite of tests were conducted that involved measurements of panel vibration and radiated sound power during point force and diffuse acoustic field excitations. Experimental results are shown and compared with Finite Element and Statistical Energy Analysis model predictions through the use of modal and energy correlation techniques among others. The behavior of the structure subject to turbulent boundary layer excitation is also numerically examined.
Early antiretroviral therapy: rationale, protease inhibitor-sparing regimens and once daily dosing.
Gatell, J M
1998-01-01
In 1998 it seems reasonable and widely accepted that all human immunodeficiency virus type 1 (HIV-1)-infected patients willing to be treated may benefit from receiving antiretroviral therapy. Only those with undetectable plasma HIV-1 RNA, normal CD4 lymphocyte counts and lack of markers of immunological system activation may be possible exceptions. The rationale supporting the early initiation of antiretroviral therapy are (i) data on viral dynamics; (ii) preliminary data pointing toward a better and a quicker restoration of immune function when treatment is initiated in very early stages (during or within a few weeks or months of acute symptomatic or asymptomatic HIV-1 infection); (iii) the lack of a stable viral load set-point even in patients in the early stages (CD4 > 500 cells/mm3) who have a very low viral load (< 5000 copies/ml); (iv) the relatively high likelihood of clinical progression at mid-term of the approximately 50-75% of patients in very early disease stages (CD4 > 500 cells/mm3) who have a plasma viral load above 5000 to 10,000 HIV-1 RNA copies/ml; (v) data from the Spanish Earth-1 study, which used a composite endpoint (virological, immunological or clinical progression), demonstrating that even in these very early stages of HIV-1 disease any antiretroviral therapy (double or triple combination) was better than no treatment. Even in early disease stages, a triple combination is needed to achieve a durable and profound virological and immunological response. In addition, the combination of stavudine plus didanosine has several advantages and can be considered one of the best double nucleoside combinations to combine with a protease inhibitor or with a non-nucleoside reverse transcriptase inhibitor. The INCAS study and the preliminary results of the ongoing Spanish SCAN study have demonstrated the possibility of protease inhibitor-sparing combinations for initial antiretroviral treatment, at least in selected patient subsets, such as those with a relatively low baseline viral load. Furthermore, components of these protease inhibitor-sparing combinations such as didanosine or nevirapine are suitable for once daily administration.
Mousavi, S Jamaleddin; Avril, Stéphane
2017-10-01
It is now a rather common approach to perform patient-specific stress analyses of arterial walls using finite-element models reconstructed from gated medical images. However, this requires to compute for every Gauss point the deformation gradient between the current configuration and a stress-free reference configuration. It is technically difficult to define such a reference configuration, and there is actually no guarantee that a stress-free configuration is physically attainable due to the presence of internal stresses in unloaded soft tissues. An alternative framework was proposed by Bellini et al. (Ann Biomed Eng 42(3):488-502, 2014). It consists of computing the deformation gradients between the current configuration and a prestressed reference configuration. We present here the first finite-element results based on this concept using the Abaqus software. The reference configuration is set arbitrarily to the in vivo average geometry of the artery, which is obtained from gated medical images and is assumed to be mechanobiologically homeostatic. For every Gauss point, the stress is split additively into the contributions of each individual load-bearing constituent of the tissue, namely elastin, collagen, smooth muscle cells. Each constituent is assigned an independent prestretch in the reference configuration, named the deposition stretch. The outstanding advantage of the present approach is that it simultaneously computes the in situ stresses existing in the reference configuration and predicts the residual stresses that occur after removing the different loadings applied onto the artery (pressure and axial load). As a proof of concept, we applied it on an ideal thick-wall cylinder and showed that the obtained results were consistent with corresponding experimental and analytical results of the well-known literature. In addition, we developed a patient-specific model of a human ascending thoracic aneurysmal aorta and demonstrated the utility in predicting the wall stress distribution in vivo under the effects of physiological pressure. Finally, we simulated the whole process preceding traditional in vitro uniaxial tensile testing of arteries, including excision from the body, radial cutting, flattening and subsequent tensile loading, showing how this process may impact the final mechanical properties derived from these in vitro tests.
Subcritical crack growth in SiNx thin-film barriers studied by electro-mechanical two-point bending
NASA Astrophysics Data System (ADS)
Guan, Qingling; Laven, Jozua; Bouten, Piet C. P.; de With, Gijsbertus
2013-06-01
Mechanical failure resulting from subcritical crack growth in the SiNx inorganic barrier layer applied on a flexible multilayer structure was studied by an electro-mechanical two-point bending method. A 10 nm conducting tin-doped indium oxide layer was sputtered as an electrical probe to monitor the subcritical crack growth in the 150 nm dielectric SiNx layer carried by a polyethylene naphthalate substrate. In the electro-mechanical two-point bending test, dynamic and static loads were applied to investigate the crack propagation in the barrier layer. As consequence of using two loading modes, the characteristic failure strain and failure time could be determined. The failure probability distribution of strain and lifetime under each loading condition was described by Weibull statistics. In this study, results from the tests in dynamic and static loading modes were linked by a power law description to determine the critical failure over a range of conditions. The fatigue parameter n from the power law reduces greatly from 70 to 31 upon correcting for internal strain. The testing method and analysis tool as described in the paper can be used to understand the limit of thin-film barriers in terms of their mechanical properties.
NASA Astrophysics Data System (ADS)
Mazúr, P.; Mrlík, J.; Beneš, J.; Pocedič, J.; Vrána, J.; Dundálek, J.; Kosek, J.
2018-03-01
In our contribution we study the electrocatalytic effect of oxygen functionalization of thermally treated graphite felt on kinetics of electrode reactions of vanadium redox flow battery. Chemical and morphological changes of the felts are analysed by standard physico-chemical characterization techniques. A complex method four-point method is developed and employed for characterization of the felts in a laboratory single-cell. The method is based on electrochemical impedance spectroscopy and load curves measurements of positive and negative half-cells using platinum wire pseudo-reference electrodes. The distribution of ohmic and faradaic losses within a single-cell is evaluated for both symmetric and asymmetric electrode set-up with respect to the treatment conditions. Positive effect of oxygen functionalization is observed only for negative electrode, whereas kinetics of positive electrode reaction is almost unaffected by the treatment. This is in a contradiction to the results of typically employed cyclovoltammetric characterization which indicate that both electrodes are enhanced by the treatment to a similar extent. The developed four-point characterization method can be further used e.g., for the component screening and in-situ durability studies on single-cell scale redox flow batteries of various chemistries.
A New Global Regression Analysis Method for the Prediction of Wind Tunnel Model Weight Corrections
NASA Technical Reports Server (NTRS)
Ulbrich, Norbert Manfred; Bridge, Thomas M.; Amaya, Max A.
2014-01-01
A new global regression analysis method is discussed that predicts wind tunnel model weight corrections for strain-gage balance loads during a wind tunnel test. The method determines corrections by combining "wind-on" model attitude measurements with least squares estimates of the model weight and center of gravity coordinates that are obtained from "wind-off" data points. The method treats the least squares fit of the model weight separate from the fit of the center of gravity coordinates. Therefore, it performs two fits of "wind- off" data points and uses the least squares estimator of the model weight as an input for the fit of the center of gravity coordinates. Explicit equations for the least squares estimators of the weight and center of gravity coordinates are derived that simplify the implementation of the method in the data system software of a wind tunnel. In addition, recommendations for sets of "wind-off" data points are made that take typical model support system constraints into account. Explicit equations of the confidence intervals on the model weight and center of gravity coordinates and two different error analyses of the model weight prediction are also discussed in the appendices of the paper.
Novel pH sensing semiconductor for point-of-care detection of HIV-1 viremia
Gurrala, R.; Lang, Z.; Shepherd, L.; Davidson, D.; Harrison, E.; McClure, M.; Kaye, S.; Toumazou, C.; Cooke, G. S.
2016-01-01
The timely detection of viremia in HIV-infected patients receiving antiviral treatment is key to ensuring effective therapy and preventing the emergence of drug resistance. In high HIV burden settings, the cost and complexity of diagnostics limit their availability. We have developed a novel complementary metal-oxide semiconductor (CMOS) chip based, pH-mediated, point-of-care HIV-1 viral load monitoring assay that simultaneously amplifies and detects HIV-1 RNA. A novel low-buffer HIV-1 pH-LAMP (loop-mediated isothermal amplification) assay was optimised and incorporated into a pH sensitive CMOS chip. Screening of 991 clinical samples (164 on the chip) yielded a sensitivity of 95% (in vitro) and 88.8% (on-chip) at >1000 RNA copies/reaction across a broad spectrum of HIV-1 viral clades. Median time to detection was 20.8 minutes in samples with >1000 copies RNA. The sensitivity, specificity and reproducibility are close to that required to produce a point-of-care device which would be of benefit in resource poor regions, and could be performed on an USB stick or similar low power device. PMID:27829667
URBAN/SUBURBAN WATERSHED CHARACTERIZATION
The ability to characterize the land surface and related pollutant source loadings is critical for reliable watershed modeling. Urban/suburban land uses are the most rapidly growing land use class, generating non-point source pollutant loadings likely to seriously impair streams...
46 CFR 44.05-35 - Form of load line certificate.
Code of Federal Regulations, 2012 CFR
2012-10-01
... steamers navigate a river or inland water, deeper loading is permitted corresponding to the weight of fuel, etc., required for consumption between the point of departure and the open sea. The upper edge of the...
46 CFR 44.05-35 - Form of load line certificate.
Code of Federal Regulations, 2014 CFR
2014-10-01
... steamers navigate a river or inland water, deeper loading is permitted corresponding to the weight of fuel, etc., required for consumption between the point of departure and the open sea. The upper edge of the...
46 CFR 44.05-35 - Form of load line certificate.
Code of Federal Regulations, 2013 CFR
2013-10-01
... steamers navigate a river or inland water, deeper loading is permitted corresponding to the weight of fuel, etc., required for consumption between the point of departure and the open sea. The upper edge of the...
46 CFR 44.05-35 - Form of load line certificate.
Code of Federal Regulations, 2011 CFR
2011-10-01
... steamers navigate a river or inland water, deeper loading is permitted corresponding to the weight of fuel, etc., required for consumption between the point of departure and the open sea. The upper edge of the...
Real-Time Unsteady Loads Measurements Using Hot-Film Sensors
NASA Technical Reports Server (NTRS)
Mangalam, Arun S.; Moes, Timothy R.
2004-01-01
Several flight-critical aerodynamic problems such as buffet, flutter, stall, and wing rock are strongly affected or caused by abrupt changes in unsteady aerodynamic loads and moments. Advanced sensing and flow diagnostic techniques have made possible simultaneous identification and tracking, in realtime, of the critical surface, viscosity-related aerodynamic phenomena under both steady and unsteady flight conditions. The wind tunnel study reported here correlates surface hot-film measurements of leading edge stagnation point and separation point, with unsteady aerodynamic loads on a NACA 0015 airfoil. Lift predicted from the correlation model matches lift obtained from pressure sensors for an airfoil undergoing harmonic pitchup and pitchdown motions. An analytical model was developed that demonstrates expected stall trends for pitchup and pitchdown motions. This report demonstrates an ability to obtain unsteady aerodynamic loads in real time, which could lead to advances in air vehicle safety, performance, ride-quality, control, and health management.
Real-Time Unsteady Loads Measurements Using Hot-Film Sensors
NASA Technical Reports Server (NTRS)
Mangalam, Arun S.; Moes, Timothy R.
2004-01-01
Several flight-critical aerodynamic problems such as buffet, flutter, stall, and wing rock are strongly affected or caused by abrupt changes in unsteady aerodynamic loads and moments. Advanced sensing and flow diagnostic techniques have made possible simultaneous identification and tracking, in real-time, of the critical surface, viscosity-related aerodynamic phenomena under both steady and unsteady flight conditions. The wind tunnel study reported here correlates surface hot-film measurements of leading edge stagnation point and separation point, with unsteady aerodynamic loads on a NACA 0015 airfoil. Lift predicted from the correlation model matches lift obtained from pressure sensors for an airfoil undergoing harmonic pitchup and pitchdown motions. An analytical model was developed that demonstrates expected stall trends for pitchup and pitchdown motions. This report demonstrates an ability to obtain unsteady aerodynamic loads in real-time, which could lead to advances in air vehicle safety, performance, ride-quality, control, and health management.
NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.; Sotiris, Kellas
2006-01-01
Static 3-point bend tests of Reinforced Carbon-Carbon (RCC) were conducted to failure to provide data for additional validation of an LS-DYNA RCC model suitable for predicting the threshold of impact damage to shuttle orbiter wing leading edges. LS-DYNA predictions correlated well with the average RCC failure load, and were good in matching the load vs. deflection. However, correlating the detectable damage using NDE methods with the cumulative damage parameter in LS-DYNA material model 58 was not readily achievable. The difficulty of finding internal RCC damage with NDE and the high sensitivity of the mat58 damage parameter to the load near failure made the task very challenging. In addition, damage mechanisms for RCC due to dynamic impact of debris such as foam and ice and damage mechanisms due to a static loading were, as expected, not equivalent.
Comparative cephalopod shell strength and the role of septum morphology on stress distribution
Zachow, Stefan; Hoffmann, René
2016-01-01
The evolution of complexly folded septa in ammonoids has long been a controversial topic. Explanations of the function of these folded septa can be divided into physiological and mechanical hypotheses with the mechanical functions tending to find widespread support. The complexity of the cephalopod shell has made it difficult to directly test the mechanical properties of these structures without oversimplification of the septal morphology or extraction of a small sub-domain. However, the power of modern finite element analysis now permits direct testing of mechanical hypothesis on complete, empirical models of the shells taken from computed tomographic data. Here we compare, for the first time using empirical models, the capability of the shells of extant Nautilus pompilius, Spirula spirula, and the extinct ammonite Cadoceras sp. to withstand hydrostatic pressure and point loads. Results show hydrostatic pressure imparts highest stress on the final septum with the rest of the shell showing minimal compression. S. spirula shows the lowest stress under hydrostatic pressure while N. pompilius shows the highest stress. Cadoceras sp. shows the development of high stress along the attachment of the septal saddles with the shell wall. Stress due to point loads decreases when the point force is directed along the suture as opposed to the unsupported chamber wall. Cadoceras sp. shows the greatest decrease in stress between the point loads compared to all other models. Greater amplitude of septal flutes corresponds with greater stress due to hydrostatic pressure; however, greater amplitude decreases the stress magnitude of point loads directed along the suture. In our models, sutural complexity does not predict greater resistance to hydrostatic pressure but it does seem to increase resistance to point loads, such as would be from predators. This result permits discussion of palaeoecological reconstructions on the basis of septal morphology. We further suggest that the ratio used to characterize septal morphology in the septal strength index and in calculations of tensile strength of nacre are likely insufficient. A better understanding of the material properties of cephalopod nacre may allow the estimation of maximum depth limits of shelled cephalopods through finite element analysis. PMID:27672501
Duarte, Felipe Coutinho Kullmann; Kolberg, Carolina; Barros, Rodrigo R; Silva, Vivian G A; Gehlen, Günter; Vassoler, Jakson M; Partata, Wania A
2014-05-01
This study was designed to assess the peak force of a manually operated chiropractic adjusting instrument, the Activator Adjusting Instrument 4 (AAI 4), with an adapter for use in animals, which has a 3- to 4-fold smaller contact surface area than the original rubber tip. Peak force was determined by thrusting the AAI 4 with the adapter or the original rubber tip onto a load cell. First, the AAI 4 was applied perpendicularly by a doctor of chiropractic onto the load cell. Then, the AAI 4 was fixed in a rigid framework and applied to the load cell. This procedure was done to prevent any load on the load cell before the thrust impulse. In 2 situations, trials were performed with the AAI 4 at all force settings (settings I, II, III, and IV, minimum to maximum, respectively). A total of 50000 samples per second over a period of 3 seconds were collected. In 2 experimental protocols, the use of the adapter in the AAI 4 increased the peak force only with setting I. The new value was around 80% of the maximum value found for the AAI 4. Nevertheless, the peak force values of the AAI 4 with the adapter and with the original rubber tip in setting IV were similar. The adapter effectively determines the maximum peak force value at force setting I of AAI 4. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
46 CFR 64.59 - Spring loaded pressure relief valve.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Spring loaded pressure relief valve. 64.59 Section 64.59... AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.59 Spring loaded pressure relief valve. A spring loaded pressure relief valve must— (a) Be set at a nominal...
46 CFR 64.59 - Spring loaded pressure relief valve.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Spring loaded pressure relief valve. 64.59 Section 64.59... AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.59 Spring loaded pressure relief valve. A spring loaded pressure relief valve must— (a) Be set at a nominal...
46 CFR 64.59 - Spring loaded pressure relief valve.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Spring loaded pressure relief valve. 64.59 Section 64.59... AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.59 Spring loaded pressure relief valve. A spring loaded pressure relief valve must— (a) Be set at a nominal...
46 CFR 64.59 - Spring loaded pressure relief valve.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Spring loaded pressure relief valve. 64.59 Section 64.59... AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.59 Spring loaded pressure relief valve. A spring loaded pressure relief valve must— (a) Be set at a nominal...
46 CFR 64.59 - Spring loaded pressure relief valve.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Spring loaded pressure relief valve. 64.59 Section 64.59... AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.59 Spring loaded pressure relief valve. A spring loaded pressure relief valve must— (a) Be set at a nominal...
Leukodepletion as a Point-of-Care Method for Monitoring HIV-1 Viral Load in Whole Blood
Titchmarsh, Logan; Zeh, Clement; Verpoort, Thierry; Allain, Jean-Pierre
2014-01-01
In order to limit the interference of HIV-1 cellular nucleic acids in estimating viral load (VL), the feasibility of leukodepletion of a small whole-blood (WB) volume to eliminate only leukocyte cell content was investigated, using a selection of filters. The efficacy of leukocyte filtration was evaluated by counting, CD45 quantitative PCR, and HIV-1 DNA quantification. Plasma HIV-1 was tested by real-time reverse transcription (RT)-PCR. A specific, miniaturized filter was developed and tested for leukocyte and plasma virus retention, WB sample dilution, and filtration parameters in HIV-1-spiked WB samples. This device proved effective to retain >99.9% of white blood cells in 100 μl of WB without affecting plasma VL. The Samba sample preparation chemistry was adapted to use a leukodepleted WB sample for VL monitoring using the point-of-care Samba-1 semiautomated system. The clinical performance of the assay was evaluated by testing 207 consecutive venous EDTA WB samples from HIV-1-infected patients attending a CD4 testing clinic. Most patients were on antiretroviral treatment (ART), but their VL status was unknown. Compared to the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test, the new Samba assay had a concordance of 96.5%. The use of the Samba system with a VL test for WB might contribute to HIV-1 ART management and reduce loss-to-follow-up rates in resource-limited settings. PMID:25428162
NASA Astrophysics Data System (ADS)
Mössinger, Peter; Jester-Zürker, Roland; Jung, Alexander
2015-01-01
Numerical investigations of hydraulic turbo machines under steady-state conditions are state of the art in current product development processes. Nevertheless allow increasing computational resources refined discretization methods, more sophisticated turbulence models and therefore better predictions of results as well as the quantification of existing uncertainties. Single stage investigations are done using in-house tools for meshing and set-up procedure. Beside different model domains and a mesh study to reduce mesh dependencies, the variation of several eddy viscosity and Reynolds stress turbulence models are investigated. All obtained results are compared with available model test data. In addition to global values, measured magnitudes in the vaneless space, at runner blade and draft tube positions in term of pressure and velocity are considered. From there it is possible to estimate the influence and relevance of various model domains depending on different operating points and numerical variations. Good agreement can be found for pressure and velocity measurements with all model configurations and, except the BSL-RSM model, all turbulence models. At part load, deviations in hydraulic efficiency are at a large magnitude, whereas at best efficiency and high load operating point efficiencies are close to the measurement. A consideration of the runner side gap geometry as well as a refined mesh is able to improve the results either in relation to hydraulic efficiency or velocity distribution with the drawbacks of less stable numerics and increasing computational time.
Reumann, Matthias; Fitch, Blake G; Rayshubskiy, Aleksandr; Keller, David U J; Seemann, Gunnar; Dossel, Olaf; Pitman, Michael C; Rice, John J
2009-01-01
Orthogonal recursive bisection (ORB) algorithm can be used as data decomposition strategy to distribute a large data set of a cardiac model to a distributed memory supercomputer. It has been shown previously that good scaling results can be achieved using the ORB algorithm for data decomposition. However, the ORB algorithm depends on the distribution of computational load of each element in the data set. In this work we investigated the dependence of data decomposition and load balancing on different rotations of the anatomical data set to achieve optimization in load balancing. The anatomical data set was given by both ventricles of the Visible Female data set in a 0.2 mm resolution. Fiber orientation was included. The data set was rotated by 90 degrees around x, y and z axis, respectively. By either translating or by simply taking the magnitude of the resulting negative coordinates we were able to create 14 data set of the same anatomy with different orientation and position in the overall volume. Computation load ratios for non - tissue vs. tissue elements used in the data decomposition were 1:1, 1:2, 1:5, 1:10, 1:25, 1:38.85, 1:50 and 1:100 to investigate the effect of different load ratios on the data decomposition. The ten Tusscher et al. (2004) electrophysiological cell model was used in monodomain simulations of 1 ms simulation time to compare performance using the different data sets and orientations. The simulations were carried out for load ratio 1:10, 1:25 and 1:38.85 on a 512 processor partition of the IBM Blue Gene/L supercomputer. Th results show that the data decomposition does depend on the orientation and position of the anatomy in the global volume. The difference in total run time between the data sets is 10 s for a simulation time of 1 ms. This yields a difference of about 28 h for a simulation of 10 s simulation time. However, given larger processor partitions, the difference in run time decreases and becomes less significant. Depending on the processor partition size, future work will have to consider the orientation of the anatomy in the global volume for longer simulation runs.
Bulk electric system reliability evaluation incorporating wind power and demand side management
NASA Astrophysics Data System (ADS)
Huang, Dange
Electric power systems are experiencing dramatic changes with respect to structure, operation and regulation and are facing increasing pressure due to environmental and societal constraints. Bulk electric system reliability is an important consideration in power system planning, design and operation particularly in the new competitive environment. A wide range of methods have been developed to perform bulk electric system reliability evaluation. Theoretically, sequential Monte Carlo simulation can include all aspects and contingencies in a power system and can be used to produce an informative set of reliability indices. It has become a practical and viable tool for large system reliability assessment technique due to the development of computing power and is used in the studies described in this thesis. The well-being approach used in this research provides the opportunity to integrate an accepted deterministic criterion into a probabilistic framework. This research work includes the investigation of important factors that impact bulk electric system adequacy evaluation and security constrained adequacy assessment using the well-being analysis framework. Load forecast uncertainty is an important consideration in an electrical power system. This research includes load forecast uncertainty considerations in bulk electric system reliability assessment and the effects on system, load point and well-being indices and reliability index probability distributions are examined. There has been increasing worldwide interest in the utilization of wind power as a renewable energy source over the last two decades due to enhanced public awareness of the environment. Increasing penetration of wind power has significant impacts on power system reliability, and security analyses become more uncertain due to the unpredictable nature of wind power. The effects of wind power additions in generating and bulk electric system reliability assessment considering site wind speed correlations and the interactive effects of wind power and load forecast uncertainty on system reliability are examined. The concept of the security cost associated with operating in the marginal state in the well-being framework is incorporated in the economic analyses associated with system expansion planning including wind power and load forecast uncertainty. Overall reliability cost/worth analyses including security cost concepts are applied to select an optimal wind power injection strategy in a bulk electric system. The effects of the various demand side management measures on system reliability are illustrated using the system, load point, and well-being indices, and the reliability index probability distributions. The reliability effects of demand side management procedures in a bulk electric system including wind power and load forecast uncertainty considerations are also investigated. The system reliability effects due to specific demand side management programs are quantified and examined in terms of their reliability benefits.
Nishino, Katsutoshi; Omori, Go; Koga, Yoshio; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji; Tanaka, Masaei; Arakawa, Masaaki
2015-07-01
We recently developed a new method for three-dimensional evaluation of mechanical factors affecting knee joint in order to help identify factors that contribute to the progression of knee osteoarthritis (KOA). This study aimed to verify the clinical validity of our method by evaluating knee joint dynamics during gait. Subjects were 41 individuals (14 normal knees; 8 mild KOAs; 19 severe KOAs). The positions of skin markers attached to the body were captured during gait, and bi-planar X-ray images of the lower extremities were obtained in standing position. The positional relationship between the markers and femorotibial bones was determined from the X-ray images. Combining this relationship with gait capture allowed for the estimation of relative movement between femorotibial bones. We also calculated the point of intersection of loading axis of knee on the tibial proximal surface (LAK point) to analyze knee joint dynamics. Knee flexion range in subjects with severe KOA during gait was significantly smaller than that in those with normal knees (p=0.011), and knee adduction in those with severe KOA was significantly larger than in those with mild KOA (p<0.000). LAK point was locally loaded on the medial compartment of the tibial surface as KOA progressed, with LAK point of subjects with severe KOA rapidly shifting medially during loading response. Local loading and medial shear force were applied to the tibial surface during stance phase as medial KOA progressed. Our findings suggest that our method is useful for the quantitative evaluation of mechanical factors that affect KOA progression. Copyright © 2015 Elsevier B.V. All rights reserved.
Etheridge, Alexandra B.
2013-01-01
he U.S. Geological Survey (USGS), in cooperation with Idaho Department of Environmental Quality, developed spreadsheet mass-balance models for total phosphorus using results from three synoptic sampling periods conducted in the lower Boise River watershed during August and October 2012, and March 2013. The modeling reach spanned 46.4 river miles (RM) along the Boise River from Veteran’s Memorial Parkway in Boise, Idaho (RM 50.2), to Parma, Idaho (RM 3.8). The USGS collected water-quality samples and measured streamflow at 14 main-stem Boise River sites, two Boise River north channel sites, two sites on the Snake River upstream and downstream of its confluence with the Boise River, and 17 tributary and return-flow sites. Additional samples were collected from treated effluent at six wastewater treatment plants and two fish hatcheries. The Idaho Department of Water Resources quantified diversion flows in the modeling reach. Total phosphorus mass-balance models were useful tools for evaluating sources of phosphorus in the Boise River during each sampling period. The timing of synoptic sampling allowed the USGS to evaluate phosphorus inputs to and outputs from the Boise River during irrigation season, shortly after irrigation ended, and soon before irrigation resumed. Results from the synoptic sampling periods showed important differences in surface-water and groundwater distribution and phosphorus loading. In late August 2012, substantial streamflow gains to the Boise River occurred from Middleton (RM 31.4) downstream to Parma (RM 3.8). Mass-balance model results indicated that point and nonpoint sources (including groundwater) contributed phosphorus loads to the Boise River during irrigation season. Groundwater exchange within the Boise River in October 2012 and March 2013 was not as considerable as that measured in August 2012. However, groundwater discharge to agricultural tributaries and drains during non-irrigation season was a large source of discharge and phosphorus in the lower Boise River in October 2012 and March 2013. Model results indicate that point sources represent the largest contribution of phosphorus to the Boise River year round, but that reductions in point and nonpoint source phosphorus loads may be necessary to achieve seasonal total phosphorus concentration targets at Parma (RM 3.8) from May 1 through September 30, as set by the 2004 Snake River-Hells Canyon Total Maximum Daily Load document. The mass-balance models do not account for biological or depositional instream processes, but are useful indicators of locations where appreciable phosphorus uptake or release by aquatic plants may occur.
1984-02-01
Added Generators and Breakers 116 * ix I~ Table of Contents (cont.) Item Pace Excitation System 117 Connection to Load 117 Bridge Crane 117 Lower St...118 Added Generator and Breaker 119 Excitation System 120 Connection to Load 120 Mobile Crane 120 Civil Features - Upper Falls 120 Powerhouse 121...intermediate plants fully integrated with the base loaded thermal plants in the area. Gavins Point is generally base- loaded to provide steady flows for
Working Memory Load Affects Processing Time in Spoken Word Recognition: Evidence from Eye-Movements
Hadar, Britt; Skrzypek, Joshua E.; Wingfield, Arthur; Ben-David, Boaz M.
2016-01-01
In daily life, speech perception is usually accompanied by other tasks that tap into working memory capacity. However, the role of working memory on speech processing is not clear. The goal of this study was to examine how working memory load affects the timeline for spoken word recognition in ideal listening conditions. We used the “visual world” eye-tracking paradigm. The task consisted of spoken instructions referring to one of four objects depicted on a computer monitor (e.g., “point at the candle”). Half of the trials presented a phonological competitor to the target word that either overlapped in the initial syllable (onset) or at the last syllable (offset). Eye movements captured listeners' ability to differentiate the target noun from its depicted phonological competitor (e.g., candy or sandal). We manipulated working memory load by using a digit pre-load task, where participants had to retain either one (low-load) or four (high-load) spoken digits for the duration of a spoken word recognition trial. The data show that the high-load condition delayed real-time target discrimination. Specifically, a four-digit load was sufficient to delay the point of discrimination between the spoken target word and its phonological competitor. Our results emphasize the important role working memory plays in speech perception, even when performed by young adults in ideal listening conditions. PMID:27242424
DOE Office of Scientific and Technical Information (OSTI.GOV)
Small, Ward; Pearson, Mark A.; Maiti, Amitesh
Dow Corning SE 1700 (reinforced polydimethylsiloxane) porous structures were made by direct ink writing (DIW). The specimens (~50% porosity) were subjected to various compressive strains (15, 30, 45%) and temperatures (room temperature, 35, 50, 70°C) in a nitrogen atmosphere (active purge) for 1 year. Compression set and load retention of the aged specimens were measured periodically during the study. Compression set increased with strain and temperature. After 1 year, specimens aged at room temperature, 35, and 50°C showed ~10% compression set (relative to the applied compressive deflection), while those aged at 70°C showed 20-40%. Due to the increasing compression set,more » load retention decreased with temperature, ranging from ~90% at room temperature to ~60-80% at 70°C. Long-term compression set and load retention at room temperature were predicted by applying time-temperature superposition (TTS). The predictions show compression set relative to the compressive deflection will be ~10-15% with ~70-90% load retention after 50 years at 15-45% strain, suggesting the material will continue to be mechanically functional. Comparison of the results to previously acquired data for cellular (M97*, M9760, M9763) and RTV (S5370) silicone foams suggests that the SE 1700 DIW porous specimens are on par with, or outperform, the legacy foams.« less
Electric Propulsion Pointing Mechanism for BepiColombo
NASA Astrophysics Data System (ADS)
Janu, Paul; Neugebauer, Christian; Schermann, Rudolf; Supper, Ludwig
2013-09-01
Since 17 years the development of Electric Propulsion Pointing Mechanisms for commercial and scientific satellite applications is a key-product activity for RUAG Space in Vienna.As one of the most innovative EP mechanisms presently under development in Vienna this paper presents the Electric Propulsion Mechanism for the ESA Bepi Colombo Mission.RUAG Space delivers the mechanism assembly, consisting of the mechanisms and the control electronics.The design-driving requirements are:- the pointing capability around the stowed configuration under resitive torque coming from the thruster supply harness, the thruster supply piping, and the mechanism harness. The pointing capability around the stowed configuration is realized via a central release nut together with a spring loaded knuckle-lever system which in essence forms a "frangible pipe" that is stiff during launch and collapses upon release. The resistive torques are minimized by a helical arrangement of the supply pipes and of the mechanism harness, and a guided low stiffness routing of the thruster supply harness. A high detent torque actuator is used to maintain pointing direction in un-powered condition. Also the direct measurement of the torque on the actuator shaft during random vibration is presented in the paper.- the specified maximum input loads to the thruster. The mechanism has not only to point the thruster, but also to protect it against high launch loads. A very low Eigen- frequency of the mechanism/thruster sub-assembly of around 65 Hz was selected to minimize coupling with the thruster's modes and so to minimize load input to the thruster. An elastomer damping system is implemented which minimizes amplification in this frequency area so that the sine input can be sustained by the mechanism and the thruster. The measured amplification of 3.1 turned out to successfully protect the thruster from the launch vibrations.- the thermal load on the mechanism from the dissipation of the thruster and from the solar radiation.A staged temperature zone concept was selected, separating different temperature zones, and keeping the thermally sensitive elements in their operating temperature ranges.This paper outlines the design solution for these design driving requirements, presents the test results, and compares the results of the predictions with the tested values of the qualification tests. It also points out the lessons learnt during this development process.
NASA Technical Reports Server (NTRS)
Caplin, R. S.; Royer, E. R.
1978-01-01
Attempts are made to provide a total design of a Microbial Load Monitor (MLM) system flight engineering model. Activities include assembly and testing of Sample Receiving and Card Loading Devices (SRCLDs), operator related software, and testing of biological samples in the MLM. Progress was made in assembling SRCLDs with minimal leaks and which operate reliably in the Sample Loading System. Seven operator commands are used to control various aspects of the MLM such as calibrating and reading the incubating reading head, setting the clock and reading time, and status of Card. Testing of the instrument, both in hardware and biologically, was performed. Hardware testing concentrated on SRCLDs. Biological testing covered 66 clinical and seeded samples. Tentative thresholds were set and media performance listed.
Code of Federal Regulations, 2011 CFR
2011-10-01
... causing excessive stresses in the pipe or components, excessive bending or unusual loads at joints, or undesirable forces or moments at points of connection to equipment, or at anchorage or guide points. ...
Code of Federal Regulations, 2013 CFR
2013-10-01
... causing excessive stresses in the pipe or components, excessive bending or unusual loads at joints, or undesirable forces or moments at points of connection to equipment, or at anchorage or guide points. ...
Code of Federal Regulations, 2012 CFR
2012-10-01
... causing excessive stresses in the pipe or components, excessive bending or unusual loads at joints, or undesirable forces or moments at points of connection to equipment, or at anchorage or guide points. ...
Code of Federal Regulations, 2014 CFR
2014-10-01
... causing excessive stresses in the pipe or components, excessive bending or unusual loads at joints, or undesirable forces or moments at points of connection to equipment, or at anchorage or guide points. ...
Code of Federal Regulations, 2010 CFR
2010-10-01
... causing excessive stresses in the pipe or components, excessive bending or unusual loads at joints, or undesirable forces or moments at points of connection to equipment, or at anchorage or guide points. ...
Han, Qiang; Yu, Xing Xiu; Wang, Wei; Xu, Miao Miao; Ren, Rui; Zhang, Jia Peng
2017-04-18
Taking Hujiashan small watershed as the study area, based on the classified result of Landsat TM/ETM images of 2005, 2010 and 2015, combined with long-term field observation data, and used the export coefficient model, our study explored the effect of small watershed management project on temporal and spatial variation of total nitrogen (TN) load of non-point source pollution under the support of GIS technology. The results indicated that, due to the implementation of slope modification project, the area of cultivated land was significantly increased, while forest and bareland were decreased. The load of non-point source TN increased from 63208 kg in 2005 to 72778 kg in 2010, but reduced to 46876 kg in 2015. The contribution rate from residential areas was higher, the average contribution rate of the three periods was 53.5%, but it showed a decreasing trend year by year. The contribution rate of land use types was 45%, which showed an increasing trend year by year. The contribution rate of livestock was always low. From the spatial distribution, TN loading intensity was changed obviously after the terracing project. High load intensity zone was mainly concentrated on the slope of 5°-15° before terracing project. Nevertheless, high load intensity zone was concentrated on the slope of 15°-35° after terracing project, and 5°-8° had become a low load strength area. The TN load intensity changed little with time on the slope of 0°-8°, and it increased first and then decreased on the slope above 8°. With the treatment of sewage, garbage and livestock manure in rural areas, the output of nitrogen in the living and livestock breeding were significantly reduced. Due to the implementation of the project, the cultivated land area increased by 31%.
Surface Damage Mechanism of Monocrystalline Si Under Mechanical Loading
NASA Astrophysics Data System (ADS)
Zhao, Qingliang; Zhang, Quanli; To, Suet; Guo, Bing
2017-03-01
Single-point diamond scratching and nanoindentation on monocrystalline silicon wafer were performed to investigate the surface damage mechanism of Si under the contact loading. The results showed that three typical stages of material removal appeared during dynamic scratching, and a chemical reaction of Si with the diamond indenter and oxygen occurred under the high temperature. In addition, the Raman spectra of the various points in the scratching groove indicated that the Si-I to β-Sn structure (Si-II) and the following β-Sn structure (Si-II) to amorphous Si transformation appeared under the rapid loading/unloading condition of the diamond grit, and the volume change induced by the phase transformation resulted in a critical depth (ductile-brittle transition) of cut (˜60 nm ± 15 nm) much lower than the theoretical calculated results (˜387 nm). Moreover, it also led to abnormal load-displacement curves in the nanoindentation tests, resulting in the appearance of elbow and pop-out effects (˜270 nm at 20 s, 50 mN), which were highly dependent on the loading/unloading conditions. In summary, phase transformation of Si promoted surface deformation and fracture under both static and dynamic mechanical loading.
Building laboratory capacity to support HIV care in Nigeria: Harvard/APIN PEPFAR, 2004–2012
Hamel, Donald J.; Sankalé, Jean-Louis; Samuels, Jay Osi; Sarr, Abdoulaye D.; Chaplin, Beth; Ofuche, Eke; Meloni, Seema T.; Okonkwo, Prosper; Kanki, Phyllis J.
2015-01-01
Introduction From 2004–2012, the Harvard/AIDS Prevention Initiative in Nigeria, funded through the US President’s Emergency Plan for AIDS Relief programme, scaled up HIV care and treatment services in Nigeria. We describe the methodologies and collaborative processes developed to improve laboratory capacity significantly in a resource-limited setting. These methods were implemented at 35 clinic and laboratory locations. Methods Systems were established and modified to optimise numerous laboratory processes. These included strategies for clinic selection and management, equipment and reagent procurement, supply chains, laboratory renovations, equipment maintenance, electronic data management, quality development programmes and trainings. Results Over the eight-year programme, laboratories supported 160 000 patients receiving HIV care in Nigeria, delivering over 2.5 million test results, including regular viral load quantitation. External quality assurance systems were established for CD4+ cell count enumeration, blood chemistries and viral load monitoring. Laboratory equipment platforms were improved and standardised and use of point-of-care analysers was expanded. Laboratory training workshops supported laboratories toward increasing staff skills and improving overall quality. Participation in a World Health Organisation-led African laboratory quality improvement system resulted in significant gains in quality measures at five laboratories. Conclusions Targeted implementation of laboratory development processes, during simultaneous scale-up of HIV treatment programmes in a resource-limited setting, can elicit meaningful gains in laboratory quality and capacity. Systems to improve the physical laboratory environment, develop laboratory staff, create improvements to reduce costs and increase quality are available for future health and laboratory strengthening programmes. We hope that the strategies employed may inform and encourage the development of other laboratories in resource-limited settings. PMID:26900573
Using change-point models to estimate empirical critical loads for nitrogen in mountain ecosystems.
Roth, Tobias; Kohli, Lukas; Rihm, Beat; Meier, Reto; Achermann, Beat
2017-01-01
To protect ecosystems and their services, the critical load concept has been implemented under the framework of the Convention on Long-range Transboundary Air Pollution (UNECE) to develop effects-oriented air pollution abatement strategies. Critical loads are thresholds below which damaging effects on sensitive habitats do not occur according to current knowledge. Here we use change-point models applied in a Bayesian context to overcome some of the difficulties when estimating empirical critical loads for nitrogen (N) from empirical data. We tested the method using simulated data with varying sample sizes, varying effects of confounding variables, and with varying negative effects of N deposition on species richness. The method was applied to the national-scale plant species richness data from mountain hay meadows and (sub)alpine scrubs sites in Switzerland. Seven confounding factors (elevation, inclination, precipitation, calcareous content, aspect as well as indicator values for humidity and light) were selected based on earlier studies examining numerous environmental factors to explain Swiss vascular plant diversity. The estimated critical load confirmed the existing empirical critical load of 5-15 kg N ha -1 yr -1 for (sub)alpine scrubs, while for mountain hay meadows the estimated critical load was at the lower end of the current empirical critical load range. Based on these results, we suggest to narrow down the critical load range for mountain hay meadows to 10-15 kg N ha -1 yr -1 . Copyright © 2016 Elsevier Ltd. All rights reserved.
A New Distributed Optimization for Community Microgrids Scheduling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Starke, Michael R; Tomsovic, Kevin
This paper proposes a distributed optimization model for community microgrids considering the building thermal dynamics and customer comfort preference. The microgrid central controller (MCC) minimizes the total cost of operating the community microgrid, including fuel cost, purchasing cost, battery degradation cost and voluntary load shedding cost based on the customers' consumption, while the building energy management systems (BEMS) minimize their electricity bills as well as the cost associated with customer discomfort due to room temperature deviation from the set point. The BEMSs and the MCC exchange information on energy consumption and prices. When the optimization converges, the distributed generation scheduling,more » energy storage charging/discharging and customers' consumption as well as the energy prices are determined. In particular, we integrate the detailed thermal dynamic characteristics of buildings into the proposed model. The heating, ventilation and air-conditioning (HVAC) systems can be scheduled intelligently to reduce the electricity cost while maintaining the indoor temperature in the comfort range set by customers. Numerical simulation results show the effectiveness of proposed model.« less
Gooya, Ali; Lekadir, Karim; Alba, Xenia; Swift, Andrew J; Wild, Jim M; Frangi, Alejandro F
2015-01-01
Construction of Statistical Shape Models (SSMs) from arbitrary point sets is a challenging problem due to significant shape variation and lack of explicit point correspondence across the training data set. In medical imaging, point sets can generally represent different shape classes that span healthy and pathological exemplars. In such cases, the constructed SSM may not generalize well, largely because the probability density function (pdf) of the point sets deviates from the underlying assumption of Gaussian statistics. To this end, we propose a generative model for unsupervised learning of the pdf of point sets as a mixture of distinctive classes. A Variational Bayesian (VB) method is proposed for making joint inferences on the labels of point sets, and the principal modes of variations in each cluster. The method provides a flexible framework to handle point sets with no explicit point-to-point correspondences. We also show that by maximizing the marginalized likelihood of the model, the optimal number of clusters of point sets can be determined. We illustrate this work in the context of understanding the anatomical phenotype of the left and right ventricles in heart. To this end, we use a database containing hearts of healthy subjects, patients with Pulmonary Hypertension (PH), and patients with Hypertrophic Cardiomyopathy (HCM). We demonstrate that our method can outperform traditional PCA in both generalization and specificity measures.
Krüger, Antonio; Oberkircher, Ludwig; Figiel, Jens; Floßdorf, Felix; Bolzinger, Florent; Noriega, David C; Ruchholtz, Steffen
2015-05-01
The treatment of osteoporotic vertebral compression fractures using transpedicular cement augmentation has grown significantly during the past two decades. Balloon kyphoplasty was developed to restore vertebral height and improve sagittal alignment. Several studies have shown these theoretical improvements cannot be transferred universally to the clinical setting. The aim of the current study is to evaluate two different procedures used for percutaneous augmentation of vertebral compression fractures with respect to height restoration: balloon kyphoplasty and SpineJack. Twenty-four vertebral bodies of two intact, fresh human cadaveric spines (T6-L5; donor age, 70 years and 60 years; T-score -6.8 points and -6.3 points) were scanned using computed tomography (CT) and dissected into single vertebral bodies. Vertebral wedge compression fractures were created by a material testing machine (Universal testing machine, Instron 5566, Darmstadt, Germany). The axial load was increased continuously until the height of the anterior edge of the vertebral body was reduced by 40% of the initial measured values. After 15 minutes, the load was decreased manually to 100 N. After postfracture CT, the clamped vertebral bodies were placed in a custom-made loading frame with a preload of 100 N. Twelve vertebral bodies were treated using SpineJack (SJ; Vexim, Balma, France), the 12 remaining vertebral bodies were treated with balloon kyphoplasty (BKP; Kyphon, Medtronic, Sunnyvale, CA, USA). The load was maintained during the procedure until the cement set completely. Posttreatment CT was performed. Anterior, central, and posterior height as well as the Beck index were measured prefracture and postfracture as well as after treatment. For anterior height restoration (BKP, 0.14±1.48 mm; SJ, 3.34±1.19 mm), central height restoration (BKP, 0.91±1.04 mm; SJ, 3.24±1.22 mm), and posterior restoration (BKP, 0.37±0.57 mm; SJ, 1.26±1.05), as well as the Beck index (BKP, 0.00±0.06 mm; SJ, 0.10±0.06), the values for the SpineJack group were significantly higher (p<.05) CONCLUSION: The protocols for creating wedge fractures and using the instrumentation under a constant preload of 100 N led to reproducible results and effects. The study showed that height restoration was significantly better in the SpineJack group compared with the balloon kyphoplasty group. The clinical implications include a better restoration of the sagittal balance of the spine and a reduction of the kyphotic deformity, which may relate to clinical outcome and the biological healing process. Copyright © 2015 Elsevier Inc. All rights reserved.
López-Suárez, Carlos; Castillo-Oyagüe, Raquel; Rodríguez-Alonso, Verónica; Lynch, Christopher D; Suárez-García, María-Jesús
2018-06-01
This study aims to evaluate the fracture load of differently fabricated 3-unit posterior fixed dental prostheses (FDPs) with an intermediate pontic. Fifty sets of two stainless-steel abutments were randomly assigned to five groups (n = 10 each) depending on the material and technique used for manufacturing the FDPs: (1) Metal-ceramic (MC, control); (2) Lava Zirconia (LZ, bi-layered); (3) Lava Plus (LM, monolithic); (4) VITA In-Ceram YZ (YZ, bi-layered); and (5) IPS e-max ZirCAD (ZZ, bi-layered). After being luted to the dies, all FDPs were submitted to thermo-mechanical cycling (120,000 masticatory cycles, 50 N; plus 774 thermal cycles of 5 °C/55 °C, dwell time: 30 s). Samples were then subjected to a three-point bending test until fracture in a universal testing machine (cross-head speed: 1 mm/min). Fracture load of the veneering ceramic (VF) and total fracture load (TF) were recorded. Microstructure and failure patterns were assessed. Data was analysed using one-way ANOVA and Tukey HSD post-hoc tests (α = 0.05). MC restorations recorded higher VF and TF values than did zirconia FDPs (p = 0.0001), which showed no between-group differences. Within the bi-layered groups, TF was significantly higher than VF. LM pieces registered lower average grain size than did LZ specimens (p = 0.001). Overall, the connector was the weakest part. All of the groups tested could withstand clinical chewing forces in terms of average fracture load. Zirconia-based samples performed similarly to each other, but showed lower mean fracture load values than did metal-ceramic ones. Monolithic zirconia may be recommendable for solving the chipping problem. Copyright © 2018 Elsevier Ltd. All rights reserved.
Loading Intensity Prediction by Velocity and the OMNI-RES 0-10 Scale in Bench Press.
Naclerio, Fernando; Larumbe-Zabala, Eneko
2017-02-01
Naclerio, F and Larumbe-Zabala, E. Loading intensity prediction by velocity and the OMNI-RES 0-10 scale in bench press. J Strength Cond Res 32(1): 323-329, 2017-This study examined the possibility of using movement velocity and the perceived exertion as indicators of relative load in the bench press (BP) exercise. A total of 308 young, healthy, resistance trained athletes (242 men and 66 women) performed a progressive strength test up to the one repetition maximum for the individual determination of the full load-velocity and load-exertion relationships. Longitudinal regression models were used to predict the relative load from the average velocity (AV) and the OMNI-Resistance Exercise Scales (OMNI-RES 0-10 scale), considering sets as the time-related variable. Load associated with the AV and the OMNI-RES 0-10 scale value expressed after performing a set of 1-3 repetitions were used to construct 2 adjusted predictive equations: Relative load = 107.75 - 62.97 × average velocity; and Relative load = 29.03 + 7.26 × OMNI-RES 0-10 scale value. The 2 models were capable of estimating the relative load with an accuracy of 84 and 93%, respectively. These findings confirm the ability of the 2 calculated regression models, using load-velocity and load-exertion from the OMNI-RES 0-10 scale, to accurately predict strength performance in BP.
Design of Solar Street Lamp Control System Based on MPPT
NASA Astrophysics Data System (ADS)
Cui, Fengying
This paper proposes a new solar street lamp control system which is composed of photovoltaic cell, controller, battery and load. In this system controller as the key part applies the microchip to achieve many functions. According to the nonlinear output characteristics of solar cell and the influence of environment, it uses the perturbation and observation (P&O) method to realize the maximum power point tracking (MPPT) and promotes the efficiency. In order to prolong the battery life the pulse width modulation (PWM) charge mode is selected to control the battery capacity and provent the battery from the state of over-charge and over-discharge. Meanwhile the function of temperature compensation, charge and discharge protection are set to improve the running safety and stability.
Performance of a 14.9-kW laminated-frame dc series motor with chopper controller
NASA Technical Reports Server (NTRS)
Schwab, J. R.
1979-01-01
Traction motor using two types of excitation: ripple free dc from a motor generator set for baseline data and chopped dc as supplied by a battery and chopper controller was tested. For the same average values of input voltage and current, the power output was independent of the type of excitation. At the same speeds, motor efficiency at low power output (corresponding to low duty cycle of the controller) was 5 to 10 percentage points less on chopped dc than on ripple-free dc. This illustrates that for chopped waveforms, it is incorrect to calculate input power as the product of average voltage and average current. Locked-rotor torque, no load losses, and magnetic saturation data were so determined.
HIV and host immunogenetics: unraveling the role of HLA-C.
Bardeskar, N S; Mania-Pramanik, J
2016-11-01
Host genetic factors play a major role in determining the outcome of many infections including human immunodeficiency virus (HIV). Multiple host factors have been studied till date showing their varied role in susceptibility or resistance to HIV infection. HLA-C, however, has been recently started gaining interest in researchers mind revealing its polymorphisms to have an important effect on viral load set-points, disease progression as well as transmission. In this review report, we have compiled these significant findings of HLA-C in HIV infection, in an attempt to highlight the need for further research in the area in different ethnic population to establish its role in the infection. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.