Sample records for logging detection systems

  1. Threshold detection in an on-off binary communications channel with atmospheric scintillation

    NASA Technical Reports Server (NTRS)

    Webb, W. E.; Marino, J. T., Jr.

    1974-01-01

    The optimum detection threshold in an on-off binary optical communications system operating in the presence of atmospheric turbulence was investigated assuming a poisson detection process and log normal scintillation. The dependence of the probability of bit error on log amplitude variance and received signal strength was analyzed and semi-emperical relationships to predict the optimum detection threshold derived. On the basis of this analysis a piecewise linear model for an adaptive threshold detection system is presented. Bit error probabilities for non-optimum threshold detection system were also investigated.

  2. Threshold detection in an on-off binary communications channel with atmospheric scintillation

    NASA Technical Reports Server (NTRS)

    Webb, W. E.

    1975-01-01

    The optimum detection threshold in an on-off binary optical communications system operating in the presence of atmospheric turbulence was investigated assuming a poisson detection process and log normal scintillation. The dependence of the probability of bit error on log amplitude variance and received signal strength was analyzed and semi-empirical relationships to predict the optimum detection threshold derived. On the basis of this analysis a piecewise linear model for an adaptive threshold detection system is presented. The bit error probabilities for nonoptimum threshold detection systems were also investigated.

  3. A graphical automated detection system to locate hardwood log surface defects using high-resolution three-dimensional laser scan data

    Treesearch

    Liya Thomas; R. Edward Thomas

    2011-01-01

    We have developed an automated defect detection system and a state-of-the-art Graphic User Interface (GUI) for hardwood logs. The algorithm identifies defects at least 0.5 inch high and at least 3 inches in diameter on barked hardwood log and stem surfaces. To summarize defect features and to build a knowledge base, hundreds of defects were measured, photographed, and...

  4. The design and implementation of web mining in web sites security

    NASA Astrophysics Data System (ADS)

    Li, Jian; Zhang, Guo-Yin; Gu, Guo-Chang; Li, Jian-Li

    2003-06-01

    The backdoor or information leak of Web servers can be detected by using Web Mining techniques on some abnormal Web log and Web application log data. The security of Web servers can be enhanced and the damage of illegal access can be avoided. Firstly, the system for discovering the patterns of information leakages in CGI scripts from Web log data was proposed. Secondly, those patterns for system administrators to modify their codes and enhance their Web site security were provided. The following aspects were described: one is to combine web application log with web log to extract more information, so web data mining could be used to mine web log for discovering the information that firewall and Information Detection System cannot find. Another approach is to propose an operation module of web site to enhance Web site security. In cluster server session, Density-Based Clustering technique is used to reduce resource cost and obtain better efficiency.

  5. Rule-driven defect detection in CT images of hardwood logs

    Treesearch

    Erol Sarigul; A. Lynn Abbott; Daniel L. Schmoldt

    2000-01-01

    This paper deals with automated detection and identification of internal defects in hardwood logs using computed tomography (CT) images. We have developed a system that employs artificial neural networks to perform tentative classification of logs on a pixel-by-pixel basis. This approach achieves a high level of classification accuracy for several hardwood species (...

  6. Using parallel computing methods to improve log surface defect detection methods

    Treesearch

    R. Edward Thomas; Liya Thomas

    2013-01-01

    Determining the size and location of surface defects is crucial to evaluating the potential yield and value of hardwood logs. Recently a surface defect detection algorithm was developed using the Java language. This algorithm was developed around an earlier laser scanning system that had poor resolution along the length of the log (15 scan lines per foot). A newer...

  7. An interactive machine-learning approach for defect detection in computed tomogaraphy (CT) images of hardwood logs

    Treesearch

    Erol Sarigul; A. Lynn Abbott; Daniel L. Schmoldt; Philip A. Araman

    2005-01-01

    This paper describes recent progress in the analysis of computed tomography (CT) images of hardwood logs. The long-term goal of the work is to develop a system that is capable of autonomous (or semiautonomous) detection of internal defects, so that log breakdown decisions can be optimized based on defect locations. The problem is difficult because wood exhibits large...

  8. Real World Experience With Ion Implant Fault Detection at Freescale Semiconductor

    NASA Astrophysics Data System (ADS)

    Sing, David C.; Breeden, Terry; Fakhreddine, Hassan; Gladwin, Steven; Locke, Jason; McHugh, Jim; Rendon, Michael

    2006-11-01

    The Freescale automatic fault detection and classification (FDC) system has logged data from over 3.5 million implants in the past two years. The Freescale FDC system is a low cost system which collects summary implant statistics at the conclusion of each implant run. The data is collected by either downloading implant data log files from the implant tool workstation, or by exporting summary implant statistics through the tool's automation interface. Compared to the traditional FDC systems which gather trace data from sensors on the tool as the implant proceeds, the Freescale FDC system cannot prevent scrap when a fault initially occurs, since the data is collected after the implant concludes. However, the system can prevent catastrophic scrap events due to faults which are not detected for days or weeks, leading to the loss of hundreds or thousands of wafers. At the Freescale ATMC facility, the practical applications of the FD system fall into two categories: PM trigger rules which monitor tool signals such as ion gauges and charge control signals, and scrap prevention rules which are designed to detect specific failure modes that have been correlated to yield loss and scrap. PM trigger rules are designed to detect shifts in tool signals which indicate normal aging of tool systems. For example, charging parameters gradually shift as flood gun assemblies age, and when charge control rules start to fail a flood gun PM is performed. Scrap prevention rules are deployed to detect events such as particle bursts and excessive beam noise, events which have been correlated to yield loss. The FDC system does have tool log-down capability, and scrap prevention rules often use this capability to automatically log the tool into a maintenance state while simultaneously paging the sustaining technician for data review and disposition of the affected product.

  9. A hierarchical detection method in external communication for self-driving vehicles based on TDMA.

    PubMed

    Alheeti, Khattab M Ali; Al-Ani, Muzhir Shaban; McDonald-Maier, Klaus

    2018-01-01

    Security is considered a major challenge for self-driving and semi self-driving vehicles. These vehicles depend heavily on communications to predict and sense their external environment used in their motion. They use a type of ad hoc network termed Vehicular ad hoc networks (VANETs). Unfortunately, VANETs are potentially exposed to many attacks on network and application level. This paper, proposes a new intrusion detection system to protect the communication system of self-driving cars; utilising a combination of hierarchical models based on clusters and log parameters. This security system is designed to detect Sybil and Wormhole attacks in highway usage scenarios. It is based on clusters, utilising Time Division Multiple Access (TDMA) to overcome some of the obstacles of VANETs such as high density, high mobility and bandwidth limitations in exchanging messages. This makes the security system more efficient, accurate and capable of real time detection and quick in identification of malicious behaviour in VANETs. In this scheme, each vehicle log calculates and stores different parameter values after receiving the cooperative awareness messages from nearby vehicles. The vehicles exchange their log data and determine the difference between the parameters, which is utilised to detect Sybil attacks and Wormhole attacks. In order to realize efficient and effective intrusion detection system, we use the well-known network simulator (ns-2) to verify the performance of the security system. Simulation results indicate that the security system can achieve high detection rates and effectively detect anomalies with low rate of false alarms.

  10. Detection of Anomalous Insiders in Collaborative Environments via Relational Analysis of Access Logs

    PubMed Central

    Chen, You; Malin, Bradley

    2014-01-01

    Collaborative information systems (CIS) are deployed within a diverse array of environments, ranging from the Internet to intelligence agencies to healthcare. It is increasingly the case that such systems are applied to manage sensitive information, making them targets for malicious insiders. While sophisticated security mechanisms have been developed to detect insider threats in various file systems, they are neither designed to model nor to monitor collaborative environments in which users function in dynamic teams with complex behavior. In this paper, we introduce a community-based anomaly detection system (CADS), an unsupervised learning framework to detect insider threats based on information recorded in the access logs of collaborative environments. CADS is based on the observation that typical users tend to form community structures, such that users with low a nity to such communities are indicative of anomalous and potentially illicit behavior. The model consists of two primary components: relational pattern extraction and anomaly detection. For relational pattern extraction, CADS infers community structures from CIS access logs, and subsequently derives communities, which serve as the CADS pattern core. CADS then uses a formal statistical model to measure the deviation of users from the inferred communities to predict which users are anomalies. To empirically evaluate the threat detection model, we perform an analysis with six months of access logs from a real electronic health record system in a large medical center, as well as a publicly-available dataset for replication purposes. The results illustrate that CADS can distinguish simulated anomalous users in the context of real user behavior with a high degree of certainty and with significant performance gains in comparison to several competing anomaly detection models. PMID:25485309

  11. Performance of a completely automated system for monitoring CMV DNA in plasma.

    PubMed

    Mengelle, C; Sandres-Sauné, K; Mansuy, J-M; Haslé, C; Boineau, J; Izopet, J

    2016-06-01

    Completely automated systems for monitoring CMV-DNA in plasma samples are now available. Evaluate analytical and clinical performances of the VERIS™/MDx System CMV Assay(®). Analytical performance was assessed using quantified quality controls. Clinical performance was assessed by comparison with the COBAS(®) Ampliprep™/COBAS(®) Taqman CMV test using 169 plasma samples that had tested positive with the in-house technique in whole blood. The specificity of the VERIS™/MDx System CMV Assay(®) was 99% [CI 95%: 97.7-100]. Intra-assay reproducibilities were 0.03, 0.04, 0.05 and 0.04 log10IU/ml (means 2.78, 3.70, 4.64 and 5.60 log10IU/ml) for expected values of 2.70, 3.70, 4.70 and 5.70 log10IU/ml. The inter-assay reproducibilities were 0.12 and 0.08 (means 6.30 and 2.85 log10IU/ml) for expected values of 6.28 and 2.80 log10IU/ml. The lower limit of detection was 14.6IU/ml, and the assay was linear from 2.34 to 5.58 log10IU/ml. The results for the positive samples were concordant (r=0.71, p<0.0001; slope of Deming regression 0.79 [CI 95%: 0.56-1.57] and y-intercept 0.79 [CI 95%: 0.63-0.95]). The VERIS™/MDx System CMV Assay(®) detected 18 more positive samples than did the COBAS(®) Ampliprep™/COBAS(®) Taqman CMV test and the mean virus load were higher (0.41 log10IU/ml). Patient monitoring on 68 samples collected from 17 immunosuppressed patients showed similar trends between the two assays. As secondary question, virus loads detected by the VERIS™/MDx System CMV Assay(®) were compared to those of the in-house procedure on whole blood. The results were similar between the two assays (-0.09 log10IU/ml) as were the patient monitoring trends. The performances of the VERIS™/MDx System CMV Assay(®) facilitated its routine use in monitoring CMV-DNA loads in plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Specializing network analysis to detect anomalous insider actions

    PubMed Central

    Chen, You; Nyemba, Steve; Zhang, Wen; Malin, Bradley

    2012-01-01

    Collaborative information systems (CIS) enable users to coordinate efficiently over shared tasks in complex distributed environments. For flexibility, they provide users with broad access privileges, which, as a side-effect, leave such systems vulnerable to various attacks. Some of the more damaging malicious activities stem from internal misuse, where users are authorized to access system resources. A promising class of insider threat detection models for CIS focuses on mining access patterns from audit logs, however, current models are limited in that they assume organizations have significant resources to generate label cases for training classifiers or assume the user has committed a large number of actions that deviate from “normal” behavior. In lieu of the previous assumptions, we introduce an approach that detects when specific actions of an insider deviate from expectation in the context of collaborative behavior. Specifically, in this paper, we introduce a specialized network anomaly detection model, or SNAD, to detect such events. This approach assesses the extent to which a user influences the similarity of the group of users that access a particular record in the CIS. From a theoretical perspective, we show that the proposed model is appropriate for detecting insider actions in dynamic collaborative systems. From an empirical perspective, we perform an extensive evaluation of SNAD with the access logs of two distinct environments: the patient record access logs a large electronic health record system (6,015 users, 130,457 patients and 1,327,500 accesses) and the editing logs of Wikipedia (2,394,385 revisors, 55,200 articles and 6,482,780 revisions). We compare our model with several competing methods and demonstrate SNAD is significantly more effective: on average it achieves 20–30% greater area under an ROC curve. PMID:23399988

  13. A hierarchical detection method in external communication for self-driving vehicles based on TDMA

    PubMed Central

    Al-ani, Muzhir Shaban; McDonald-Maier, Klaus

    2018-01-01

    Security is considered a major challenge for self-driving and semi self-driving vehicles. These vehicles depend heavily on communications to predict and sense their external environment used in their motion. They use a type of ad hoc network termed Vehicular ad hoc networks (VANETs). Unfortunately, VANETs are potentially exposed to many attacks on network and application level. This paper, proposes a new intrusion detection system to protect the communication system of self-driving cars; utilising a combination of hierarchical models based on clusters and log parameters. This security system is designed to detect Sybil and Wormhole attacks in highway usage scenarios. It is based on clusters, utilising Time Division Multiple Access (TDMA) to overcome some of the obstacles of VANETs such as high density, high mobility and bandwidth limitations in exchanging messages. This makes the security system more efficient, accurate and capable of real time detection and quick in identification of malicious behaviour in VANETs. In this scheme, each vehicle log calculates and stores different parameter values after receiving the cooperative awareness messages from nearby vehicles. The vehicles exchange their log data and determine the difference between the parameters, which is utilised to detect Sybil attacks and Wormhole attacks. In order to realize efficient and effective intrusion detection system, we use the well-known network simulator (ns-2) to verify the performance of the security system. Simulation results indicate that the security system can achieve high detection rates and effectively detect anomalies with low rate of false alarms. PMID:29315302

  14. PLAT: An Automated Fault and Behavioural Anomaly Detection Tool for PLC Controlled Manufacturing Systems.

    PubMed

    Ghosh, Arup; Qin, Shiming; Lee, Jooyeoun; Wang, Gi-Nam

    2016-01-01

    Operational faults and behavioural anomalies associated with PLC control processes take place often in a manufacturing system. Real time identification of these operational faults and behavioural anomalies is necessary in the manufacturing industry. In this paper, we present an automated tool, called PLC Log-Data Analysis Tool (PLAT) that can detect them by using log-data records of the PLC signals. PLAT automatically creates a nominal model of the PLC control process and employs a novel hash table based indexing and searching scheme to satisfy those purposes. Our experiments show that PLAT is significantly fast, provides real time identification of operational faults and behavioural anomalies, and can execute within a small memory footprint. In addition, PLAT can easily handle a large manufacturing system with a reasonable computing configuration and can be installed in parallel to the data logging system to identify operational faults and behavioural anomalies effectively.

  15. PLAT: An Automated Fault and Behavioural Anomaly Detection Tool for PLC Controlled Manufacturing Systems

    PubMed Central

    Ghosh, Arup; Qin, Shiming; Lee, Jooyeoun

    2016-01-01

    Operational faults and behavioural anomalies associated with PLC control processes take place often in a manufacturing system. Real time identification of these operational faults and behavioural anomalies is necessary in the manufacturing industry. In this paper, we present an automated tool, called PLC Log-Data Analysis Tool (PLAT) that can detect them by using log-data records of the PLC signals. PLAT automatically creates a nominal model of the PLC control process and employs a novel hash table based indexing and searching scheme to satisfy those purposes. Our experiments show that PLAT is significantly fast, provides real time identification of operational faults and behavioural anomalies, and can execute within a small memory footprint. In addition, PLAT can easily handle a large manufacturing system with a reasonable computing configuration and can be installed in parallel to the data logging system to identify operational faults and behavioural anomalies effectively. PMID:27974882

  16. Nondestructive rule-based defect detection and identification system in CT images of hardwood logs

    Treesearch

    Erol Sarigul; A. Lynn Abbott; Daniel L. Schmoldt

    2001-01-01

    This paper is concerned with the detection of internal defects in hardwood logs. Because the commercial value of hardwood lumber is directly related to the quantity, type, and location of defects in the wood, sawing strategies are typically chosen in an attempt to minimize the defects in the resulting boards. Traditionally, the sawyer makes sawing decisions by visually...

  17. Double stars with wide separations in the AGK3 - II. The wide binaries and the multiple systems*

    NASA Astrophysics Data System (ADS)

    Halbwachs, J.-L.; Mayor, M.; Udry, S.

    2017-02-01

    A large observation programme was carried out to measure the radial velocities of the components of a selection of common proper motion (CPM) stars to select the physical binaries. 80 wide binaries (WBs) were detected, and 39 optical pairs were identified. By adding CPM stars with separations close enough to be almost certain that they are physical, a bias-controlled sample of 116 WBs was obtained, and used to derive the distribution of separations from 100 to 30 000 au. The distribution obtained does not match the log-constant distribution, but agrees with the log-normal distribution. The spectroscopic binaries detected among the WB components were used to derive statistical information about the multiple systems. The close binaries in WBs seem to be like those detected in other field stars. As for the WBs, they seem to obey the log-normal distribution of periods. The number of quadruple systems agrees with the no correlation hypothesis; this indicates that an environment conducive to the formation of WBs does not favour the formation of subsystems with periods shorter than 10 yr.

  18. Pavement crack detection combining non-negative feature with fast LoG in complex scene

    NASA Astrophysics Data System (ADS)

    Wang, Wanli; Zhang, Xiuhua; Hong, Hanyu

    2015-12-01

    Pavement crack detection is affected by much interference in the realistic situation, such as the shadow, road sign, oil stain, salt and pepper noise etc. Due to these unfavorable factors, the exist crack detection methods are difficult to distinguish the crack from background correctly. How to extract crack information effectively is the key problem to the road crack detection system. To solve this problem, a novel method for pavement crack detection based on combining non-negative feature with fast LoG is proposed. The two key novelties and benefits of this new approach are that 1) using image pixel gray value compensation to acquisit uniform image, and 2) combining non-negative feature with fast LoG to extract crack information. The image preprocessing results demonstrate that the method is indeed able to homogenize the crack image with more accurately compared to existing methods. A large number of experimental results demonstrate the proposed approach can detect the crack regions more correctly compared with traditional methods.

  19. Automatically Log Off Upon Disappearance of Facial Image

    DTIC Science & Technology

    2005-03-01

    log off a PC when the user’s face disappears for an adjustable time interval. Among the fundamental technologies of biometrics, facial recognition is... facial recognition products. In this report, a brief overview of face detection technologies is provided. The particular neural network-based face...ensure that the user logging onto the system is the same person. Among the fundamental technologies of biometrics, facial recognition is the only

  20. Visual behavior characterization for intrusion and misuse detection

    NASA Astrophysics Data System (ADS)

    Erbacher, Robert F.; Frincke, Deborah

    2001-05-01

    As computer and network intrusions become more and more of a concern, the need for better capabilities, to assist in the detection and analysis of intrusions also increase. System administrators typically rely on log files to analyze usage and detect misuse. However, as a consequence of the amount of data collected by each machine, multiplied by the tens or hundreds of machines under the system administrator's auspices, the entirety of the data available is neither collected nor analyzed. This is compounded by the need to analyze network traffic data as well. We propose a methodology for analyzing network and computer log information visually based on the analysis of the behavior of the users. Each user's behavior is the key to determining their intent and overriding activity, whether they attempt to hide their actions or not. Proficient hackers will attempt to hide their ultimate activities, which hinders the reliability of log file analysis. Visually analyzing the users''s behavior however, is much more adaptable and difficult to counteract.

  1. High-throughput determination of octanol/water partition coefficients using a shake-flask method and novel two-phase solvent system.

    PubMed

    Morikawa, Go; Suzuka, Chihiro; Shoji, Atsushi; Shibusawa, Yoichi; Yanagida, Akio

    2016-01-05

    A high-throughput method for determining the octanol/water partition coefficient (P(o/w)) of a large variety of compounds exhibiting a wide range in hydrophobicity was established. The method combines a simple shake-flask method with a novel two-phase solvent system comprising an acetonitrile-phosphate buffer (0.1 M, pH 7.4)-1-octanol (25:25:4, v/v/v; AN system). The AN system partition coefficients (K(AN)) of 51 standard compounds for which log P(o/w) (at pH 7.4; log D) values had been reported were determined by single two-phase partitioning in test tubes, followed by measurement of the solute concentration in both phases using an automatic flow injection-ultraviolet detection system. The log K(AN) values were closely related to reported log D values, and the relationship could be expressed by the following linear regression equation: log D=2.8630 log K(AN) -0.1497(n=51). The relationship reveals that log D values (+8 to -8) for a large variety of highly hydrophobic and/or hydrophilic compounds can be estimated indirectly from the narrow range of log K(AN) values (+3 to -3) determined using the present method. Furthermore, log K(AN) values for highly polar compounds for which no log D values have been reported, such as amino acids, peptides, proteins, nucleosides, and nucleotides, can be estimated using the present method. The wide-ranging log D values (+5.9 to -7.5) of these molecules were estimated for the first time from their log K(AN) values and the above regression equation. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Comparison of soft-input-soft-output detection methods for dual-polarized quadrature duobinary system

    NASA Astrophysics Data System (ADS)

    Chang, Chun; Huang, Benxiong; Xu, Zhengguang; Li, Bin; Zhao, Nan

    2018-02-01

    Three soft-input-soft-output (SISO) detection methods for dual-polarized quadrature duobinary (DP-QDB), including maximum-logarithmic-maximum-a-posteriori-probability-algorithm (Max-log-MAP)-based detection, soft-output-Viterbi-algorithm (SOVA)-based detection, and a proposed SISO detection, which can all be combined with SISO decoding, are presented. The three detection methods are investigated at 128 Gb/s in five-channel wavelength-division-multiplexing uncoded and low-density-parity-check (LDPC) coded DP-QDB systems by simulations. Max-log-MAP-based detection needs the returning-to-initial-states (RTIS) process despite having the best performance. When the LDPC code with a code rate of 0.83 is used, the detecting-and-decoding scheme with the SISO detection does not need RTIS and has better bit error rate (BER) performance than the scheme with SOVA-based detection. The former can reduce the optical signal-to-noise ratio (OSNR) requirement (at BER=10-5) by 2.56 dB relative to the latter. The application of the SISO iterative detection in LDPC-coded DP-QDB systems makes a good trade-off between requirements on transmission efficiency, OSNR requirement, and transmission distance, compared with the other two SISO methods.

  3. Advanced Cyber Attack Modeling Analysis and Visualization

    DTIC Science & Technology

    2010-03-01

    Graph Analysis Network Web Logs Netflow Data TCP Dump Data System Logs Detect Protect Security Management What-If Figure 8. TVA attack graphs for...Clustered Graphs,” in Proceedings of the Symposium on Graph Drawing, September 1996. [25] K. Lakkaraju, W. Yurcik, A. Lee, “NVisionIP: NetFlow

  4. Detecting and classifying method based on similarity matching of Android malware behavior with profile.

    PubMed

    Jang, Jae-Wook; Yun, Jaesung; Mohaisen, Aziz; Woo, Jiyoung; Kim, Huy Kang

    2016-01-01

    Mass-market mobile security threats have increased recently due to the growth of mobile technologies and the popularity of mobile devices. Accordingly, techniques have been introduced for identifying, classifying, and defending against mobile threats utilizing static, dynamic, on-device, and off-device techniques. Static techniques are easy to evade, while dynamic techniques are expensive. On-device techniques are evasion, while off-device techniques need being always online. To address some of those shortcomings, we introduce Andro-profiler, a hybrid behavior based analysis and classification system for mobile malware. Andro-profiler main goals are efficiency, scalability, and accuracy. For that, Andro-profiler classifies malware by exploiting the behavior profiling extracted from the integrated system logs including system calls. Andro-profiler executes a malicious application on an emulator in order to generate the integrated system logs, and creates human-readable behavior profiles by analyzing the integrated system logs. By comparing the behavior profile of malicious application with representative behavior profile for each malware family using a weighted similarity matching technique, Andro-profiler detects and classifies it into malware families. The experiment results demonstrate that Andro-profiler is scalable, performs well in detecting and classifying malware with accuracy greater than 98 %, outperforms the existing state-of-the-art work, and is capable of identifying 0-day mobile malware samples.

  5. Channel simulation for direct detection optical communication systems

    NASA Technical Reports Server (NTRS)

    Tycz, M.; Fitzmaurice, M. W.

    1974-01-01

    A technique is described for simulating the random modulation imposed by atmospheric scintillation and transmitter pointing jitter on a direct detection optical communication system. The system is capable of providing signal fading statistics which obey log normal, beta, Rayleigh, Ricean or chi-squared density functions. Experimental tests of the performance of the Channel Simulator are presented.

  6. Channel simulation for direct-detection optical communication systems

    NASA Technical Reports Server (NTRS)

    Tycz, M.; Fitzmaurice, M. W.

    1974-01-01

    A technique is described for simulating the random modulation imposed by atmospheric scintillation and transmitter pointing jitter on a direct-detection optical communication system. The system is capable of providing signal fading statistics which obey log-normal, beta, Rayleigh, Ricean, or chi-square density functions. Experimental tests of the performance of the channel simulator are presented.

  7. Lidar-Incorporated Traffic Sign Detection from Video Log Images of Mobile Mapping System

    NASA Astrophysics Data System (ADS)

    Li, Y.; Fan, J.; Huang, Y.; Chen, Z.

    2016-06-01

    Mobile Mapping System (MMS) simultaneously collects the Lidar points and video log images in a scenario with the laser profiler and digital camera. Besides the textural details of video log images, it also captures the 3D geometric shape of point cloud. It is widely used to survey the street view and roadside transportation infrastructure, such as traffic sign, guardrail, etc., in many transportation agencies. Although many literature on traffic sign detection are available, they only focus on either Lidar or imagery data of traffic sign. Based on the well-calibrated extrinsic parameters of MMS, 3D Lidar points are, the first time, incorporated into 2D video log images to enhance the detection of traffic sign both physically and visually. Based on the local elevation, the 3D pavement area is first located. Within a certain distance and height of the pavement, points of the overhead and roadside traffic signs can be obtained according to the setup specification of traffic signs in different transportation agencies. The 3D candidate planes of traffic signs are then fitted using the RANSAC plane-fitting of those points. By projecting the candidate planes onto the image, Regions of Interest (ROIs) of traffic signs are found physically with the geometric constraints between laser profiling and camera imaging. The Random forest learning of the visual color and shape features of traffic signs is adopted to validate the sign ROIs from the video log images. The sequential occurrence of a traffic sign among consecutive video log images are defined by the geometric constraint of the imaging geometry and GPS movement. Candidate ROIs are predicted in this temporal context to double-check the salient traffic sign among video log images. The proposed algorithm is tested on a diverse set of scenarios on the interstate highway G-4 near Beijing, China under varying lighting conditions and occlusions. Experimental results show the proposed algorithm enhances the rate of detecting traffic signs with the incorporation of the 3D planar constraint of their Lidar points. It is promising for the robust and large-scale survey of most transportation infrastructure with the application of MMS.

  8. 75 FR 76426 - Privacy Act of 1974; System of Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-08

    ..., access control lists, file system permissions, intrusion detection and prevention systems and log..., address, mailing address, country, organization, phone, fax, mobile, pager, Defense Switched Network (DSN..., address, mailing address, country, organization, phone, fax, mobile, pager, Defense Switched Network (DSN...

  9. A Computer Vision System forLocating and Identifying Internal Log Defects Using CT Imagery

    Treesearch

    Dongping Zhu; Richard W. Conners; Frederick Lamb; Philip A. Araman

    1991-01-01

    A number of researchers have shown the ability of magnetic resonance imaging (MRI) and computer tomography (CT) imaging to detect internal defects in logs. However, if these devices are ever to play a role in the forest products industry, automatic methods for analyzing data from these devices must be developed. This paper reports research aimed at developing a...

  10. Robust encoding of stimulus identity and concentration in the accessory olfactory system.

    PubMed

    Arnson, Hannah A; Holy, Timothy E

    2013-08-14

    Sensory systems represent stimulus identity and intensity, but in the neural periphery these two variables are typically intertwined. Moreover, stable detection may be complicated by environmental uncertainty; stimulus properties can differ over time and circumstance in ways that are not necessarily biologically relevant. We explored these issues in the context of the mouse accessory olfactory system, which specializes in detection of chemical social cues and infers myriad aspects of the identity and physiological state of conspecifics from complex mixtures, such as urine. Using mixtures of sulfated steroids, key constituents of urine, we found that spiking responses of individual vomeronasal sensory neurons encode both individual compounds and mixtures in a manner consistent with a simple model of receptor-ligand interactions. Although typical neurons did not accurately encode concentration over a large dynamic range, from population activity it was possible to reliably estimate the log-concentration of pure compounds over several orders of magnitude. For binary mixtures, simple models failed to accurately segment the individual components, largely because of the prevalence of neurons responsive to both components. By accounting for such overlaps during model tuning, we show that, from neuronal firing, one can accurately estimate log-concentration of both components, even when tested across widely varying concentrations. With this foundation, the difference of logarithms, log A - log B = log A/B, provides a natural mechanism to accurately estimate concentration ratios. Thus, we show that a biophysically plausible circuit model can reconstruct concentration ratios from observed neuronal firing, representing a powerful mechanism to separate stimulus identity from absolute concentration.

  11. Operational field evaluation of the PAC-MAG man-portable magnetometer array

    NASA Astrophysics Data System (ADS)

    Keranen, Joe; Topolosky, Zeke; Schultz, Gregory; Miller, Jonathan

    2013-06-01

    Detection and discrimination of unexploded ordnance (UXO) in areas of prior conflict is of high importance to the international community and the United States government. For humanitarian applications, sensors and processing methods need to be robust, reliable, and easy to train and implement using indigenous UXO removal personnel. This paper describes system characterization, system testing, and a continental United States (CONUS) Operational Field Evaluations (OFE) of the PAC-MAG man-portable UXO detection system. System testing occurred at a government test facility in June, 2010 and December, 2011 and the OFE occurred at the same location in June, 2012. NVESD and White River Technologies personnel were present for all testing and evaluation. The PAC-MAG system is a manportable magnetometer array for the detection and characterization of ferrous UXO. System hardware includes four Cesium vapor magnetometers for detection, a Real-time Kinematic Global Position System (RTK-GPS) for sensor positioning, an electronics module for merging array data and WiFi communications and a tablet computer for transmitting and logging data. An odometer, or "hipchain" encoder, provides position information in GPS-denied areas. System software elements include data logging software and post-processing software for detection and characterization of ferrous anomalies. The output of the post-processing software is a dig list containing locations of potential UXO(s), formatted for import into the system GPS equipment for reacquisition of anomalies. Results from system characterization and the OFE will be described.

  12. Percutaneous mitral valve repair with the MitraClip system according to the predicted risk by the logistic EuroSCORE: preliminary results from the German Transcatheter Mitral Valve Interventions (TRAMI) Registry.

    PubMed

    Wiebe, Jens; Franke, Jennifer; Lubos, Edith; Boekstegers, Peter; Schillinger, Wolfgang; Ouarrak, Taoufik; May, Andreas E; Eggebrecht, Holger; Kuck, Karl-Heinz; Baldus, Stephan; Senges, Jochen; Sievert, Horst

    2014-10-01

    To evaluate in-hospital and short-term outcomes of percutaneous mitral valve repair according to patients' logistic EuroSCORE (logEuroSCORE) in a multicenter registry The logEuroSCORE is an established tool to predict the risk of mortality during cardiac surgery. In high-risk patients percutaneous mitral valve repair with the MitraClip system represents a less-invasive alternative Data from 1002 patients, who underwent percutaneous mitral valve repair with the MitraClip system, were analyzed in the German Transcatheter Mitral Valve Interventions (TRAMI) Registry. A logEuroSCORE (mortality risk in %) ≥ 20 was considered high risk Of all patients, 557 (55.6%) had a logEuroSCORE ≥ 20. Implantation of the MitraClip was successful in 95.5 % (942/986) patients. Moderate residual mitral valve regurgitation was more often detected in patients with a logEuroSCORE ≥ 20 (23.8% vs. 17.1%, respectively, P < 0.05). In patients with a logEuroSCORE ≥ 20 the procedural complication rate was 8.9% (vs. 6.4, n.s.) and the in-hospital MACCE rate 4.9% (vs. 1.4% P < 0.01). The in-hospital mortality rate in patients with a logEuroSCORE ≥ 20 and logEuroSCORE < 20 was 4.3 and 1.1%, respectively (P ≤ 0.01) CONCLUSION: Percutaneous mitral valve repair with the MitraClip system is feasible in patients with a logEuroSCORE ≥ 20 with similar procedural results compared to patients with lower predicted risk. Although mortality was four times higher than in patients with logEuroSCORE < 20, mortality in high risk patients was lower than predicted. In those with a logEuroSCORE ≥ 20, moderate residual mitral valve regurgitation was more frequent. © 2014 Wiley Periodicals, Inc.

  13. Catching errors with patient-specific pretreatment machine log file analysis.

    PubMed

    Rangaraj, Dharanipathy; Zhu, Mingyao; Yang, Deshan; Palaniswaamy, Geethpriya; Yaddanapudi, Sridhar; Wooten, Omar H; Brame, Scott; Mutic, Sasa

    2013-01-01

    A robust, efficient, and reliable quality assurance (QA) process is highly desired for modern external beam radiation therapy treatments. Here, we report the results of a semiautomatic, pretreatment, patient-specific QA process based on dynamic machine log file analysis clinically implemented for intensity modulated radiation therapy (IMRT) treatments delivered by high energy linear accelerators (Varian 2100/2300 EX, Trilogy, iX-D, Varian Medical Systems Inc, Palo Alto, CA). The multileaf collimator machine (MLC) log files are called Dynalog by Varian. Using an in-house developed computer program called "Dynalog QA," we automatically compare the beam delivery parameters in the log files that are generated during pretreatment point dose verification measurements, with the treatment plan to determine any discrepancies in IMRT deliveries. Fluence maps are constructed and compared between the delivered and planned beams. Since clinical introduction in June 2009, 912 machine log file analyses QA were performed by the end of 2010. Among these, 14 errors causing dosimetric deviation were detected and required further investigation and intervention. These errors were the result of human operating mistakes, flawed treatment planning, and data modification during plan file transfer. Minor errors were also reported in 174 other log file analyses, some of which stemmed from false positives and unreliable results; the origins of these are discussed herein. It has been demonstrated that the machine log file analysis is a robust, efficient, and reliable QA process capable of detecting errors originating from human mistakes, flawed planning, and data transfer problems. The possibility of detecting these errors is low using point and planar dosimetric measurements. Copyright © 2013 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  14. Practical life log video indexing based on content and context

    NASA Astrophysics Data System (ADS)

    Tancharoen, Datchakorn; Yamasaki, Toshihiko; Aizawa, Kiyoharu

    2006-01-01

    Today, multimedia information has gained an important role in daily life and people can use imaging devices to capture their visual experiences. In this paper, we present our personal Life Log system to record personal experiences in form of wearable video and environmental data; in addition, an efficient retrieval system is demonstrated to recall the desirable media. We summarize the practical video indexing techniques based on Life Log content and context to detect talking scenes by using audio/visual cues and semantic key frames from GPS data. Voice annotation is also demonstrated as a practical indexing method. Moreover, we apply body media sensors to record continuous life style and use body media data to index the semantic key frames. In the experiments, we demonstrated various video indexing results which provided their semantic contents and showed Life Log visualizations to examine personal life effectively.

  15. Geophysical, stratigraphic, and flow-zone logs of selected test, monitor, and water-supply wells in Cayuga County, New York

    USGS Publications Warehouse

    Anderson, J. Alton; Williams, John H.; Eckhardt, David A.V.; Miller, Todd S.

    2003-01-01

    Volatile-organic compounds have been detected in water sampled from more than 50 supply wells between the City of Auburn and Village of Union Springs in Cayuga County, New York, and the area was declared a Superfund site in 2002. In 2001-04, geophysical logs were collected from 37 test, monitor, and water-supply wells as a preliminary part of the investigation of volatile-organic compound contamination in the carbonate-bedrock aquifer system. The geophysical logs included gamma, induction, caliper, wellbore image, deviation, fluid resistivity and temperature, and flowmeter. The geophysical logs were analyzed along with core samples and outcrops of the bedrock to define the stratigraphic units and flow zones penetrated by the wells. This report describes the logging methods used in the study and presents the geophysical, stratigraphic, and flow-zone logs.

  16. A Novel High-Throughput Method for Molecular Detection of Human Pathogenic Viruses Using a Nanofluidic Real-Time PCR System

    PubMed Central

    Coudray-Meunier, Coralie; Fraisse, Audrey; Martin-Latil, Sandra; Delannoy, Sabine; Fach, Patrick; Perelle, Sylvie

    2016-01-01

    Human enteric viruses are recognized as the main causes of food- and waterborne diseases worldwide. Sensitive and quantitative detection of human enteric viruses is typically achieved through quantitative RT-PCR (RT-qPCR). A nanofluidic real-time PCR system was used to develop novel high-throughput methods for qualitative molecular detection (RT-qPCR array) and quantification of human pathogenic viruses by digital RT-PCR (RT-dPCR). The performance of high-throughput PCR methods was investigated for detecting 19 human pathogenic viruses and two main process controls used in food virology. The conventional real-time PCR system was compared to the RT-dPCR and RT-qPCR array. Based on the number of genome copies calculated by spectrophotometry, sensitivity was found to be slightly better with RT-qPCR than with RT-dPCR for 14 viruses by a factor range of from 0.3 to 1.6 log10. Conversely, sensitivity was better with RT-dPCR than with RT-qPCR for seven viruses by a factor range of from 0.10 to 1.40 log10. Interestingly, the number of genome copies determined by RT-dPCR was always from 1 to 2 log10 lower than the expected copy number calculated by RT-qPCR standard curve. The sensitivity of the RT-qPCR and RT-qPCR array assays was found to be similar for two viruses, and better with RT-qPCR than with RT-qPCR array for eighteen viruses by a factor range of from 0.7 to 3.0 log10. Conversely, sensitivity was only 0.30 log10 better with the RT-qPCR array than with conventional RT-qPCR assays for norovirus GIV detection. Finally, the RT-qPCR array and RT-dPCR assays were successfully used together to screen clinical samples and quantify pathogenic viruses. Additionally, this method made it possible to identify co-infection in clinical samples. In conclusion, given the rapidity and potential for large numbers of viral targets, this nanofluidic RT-qPCR assay should have a major impact on human pathogenic virus surveillance and outbreak investigations and is likely to be of benefit to public health. PMID:26824897

  17. WE-G-213CD-03: A Dual Complementary Verification Method for Dynamic Tumor Tracking on Vero SBRT.

    PubMed

    Poels, K; Depuydt, T; Verellen, D; De Ridder, M

    2012-06-01

    to use complementary cine EPID and gimbals log file analysis for in-vivo tracking accuracy monitoring. A clinical prototype of dynamic tracking (DT) was installed on the Vero SBRT system. This prototype version allowed tumor tracking by gimballed linac rotations using an internal-external correspondence model. The DT prototype software allowed the detailed logging of all applied gimbals rotations during tracking. The integration of an EPID on the vero system allowed the acquisition of cine EPID images during DT. We quantified the tracking error on cine EPID (E-EPID) by subtracting the target center (fiducial marker detection) and the field centroid. Dynamic gimbals log file information was combined with orthogonal x-ray verification images to calculate the in-vivo tracking error (E-kVLog). The correlation between E-kVLog and E-EPID was calculated for validation of the gimbals log file. Further, we investigated the sensitivity of the log file tracking error by introducing predefined systematic tracking errors. As an application we calculate gimbals log file tracking error for dynamic hidden target tests to investigate gravity effects and decoupled gimbals rotation from gantry rotation. Finally, calculating complementary cine EPID and log file tracking errors evaluated the clinical accuracy of dynamic tracking. A strong correlation was found between log file and cine EPID tracking error distribution during concurrent measurements (R=0.98). We found sensitivity in the gimbals log files to detect a systematic tracking error up to 0.5 mm. Dynamic hidden target tests showed no gravity influence on tracking performance and high degree of decoupled gimbals and gantry rotation during dynamic arc dynamic tracking. A submillimetric agreement between clinical complementary tracking error measurements was found. Redundancy of the internal gimbals log file with x-ray verification images with complementary independent cine EPID images was implemented to monitor the accuracy of gimballed tumor tracking on Vero SBRT. Research was financially supported by the Flemish government (FWO), Hercules Foundation and BrainLAB AG. © 2012 American Association of Physicists in Medicine.

  18. Applying the log-normal distribution to target detection

    NASA Astrophysics Data System (ADS)

    Holst, Gerald C.

    1992-09-01

    Holst and Pickard experimentally determined that MRT responses tend to follow a log-normal distribution. The log normal distribution appeared reasonable because nearly all visual psychological data is plotted on a logarithmic scale. It has the additional advantage that it is bounded to positive values; an important consideration since probability of detection is often plotted in linear coordinates. Review of published data suggests that the log-normal distribution may have universal applicability. Specifically, the log-normal distribution obtained from MRT tests appears to fit the target transfer function and the probability of detection of rectangular targets.

  19. Contrast Invariant Interest Point Detection by Zero-Norm LoG Filter.

    PubMed

    Zhenwei Miao; Xudong Jiang; Kim-Hui Yap

    2016-01-01

    The Laplacian of Gaussian (LoG) filter is widely used in interest point detection. However, low-contrast image structures, though stable and significant, are often submerged by the high-contrast ones in the response image of the LoG filter, and hence are difficult to be detected. To solve this problem, we derive a generalized LoG filter, and propose a zero-norm LoG filter. The response of the zero-norm LoG filter is proportional to the weighted number of bright/dark pixels in a local region, which makes this filter be invariant to the image contrast. Based on the zero-norm LoG filter, we develop an interest point detector to extract local structures from images. Compared with the contrast dependent detectors, such as the popular scale invariant feature transform detector, the proposed detector is robust to illumination changes and abrupt variations of images. Experiments on benchmark databases demonstrate the superior performance of the proposed zero-norm LoG detector in terms of the repeatability and matching score of the detected points as well as the image recognition rate under different conditions.

  20. Continuous Tamper-proof Logging using TPM2.0

    DTIC Science & Technology

    2014-06-16

    process each log entry. Additional hardware support could mitigate this problem. Tradeoffs between performance and security guarantees Disk write...becomes weaker as the block size increases. This problem is mitigated in protocol B by allowing offline recovery from a power failure and detection of...M.K., Isozaki, H.: Flicker : An execution infrastructure for TCB minimization. ACM SIGOPS Operating Systems Review 42(4) (2008) 315–328 24. Parno, B

  1. Expert systems for automated correlation and interpretation of wireline logs

    USGS Publications Warehouse

    Olea, R.A.

    1994-01-01

    CORRELATOR is an interactive computer program for lithostratigraphic correlation of wireline logs able to store correlations in a data base with a consistency, accuracy, speed, and resolution that are difficult to obtain manually. The automatic determination of correlations is based on the maximization of a weighted correlation coefficient using two wireline logs per well. CORRELATOR has an expert system to scan and flag incongruous correlations in the data base. The user has the option to accept or disregard the advice offered by the system. The expert system represents knowledge through production rules. The inference system is goal-driven and uses backward chaining to scan through the rules. Work in progress is used to illustrate the potential that a second expert system with a similar architecture for interpreting dip diagrams could have to identify episodes-as those of interest in sequence stratigraphy and fault detection- and annotate them in the stratigraphic column. Several examples illustrate the presentation. ?? 1994 International Association for Mathematical Geology.

  2. Detecting Anomalous Insiders in Collaborative Information Systems

    PubMed Central

    Chen, You; Nyemba, Steve; Malin, Bradley

    2012-01-01

    Collaborative information systems (CISs) are deployed within a diverse array of environments that manage sensitive information. Current security mechanisms detect insider threats, but they are ill-suited to monitor systems in which users function in dynamic teams. In this paper, we introduce the community anomaly detection system (CADS), an unsupervised learning framework to detect insider threats based on the access logs of collaborative environments. The framework is based on the observation that typical CIS users tend to form community structures based on the subjects accessed (e.g., patients’ records viewed by healthcare providers). CADS consists of two components: 1) relational pattern extraction, which derives community structures and 2) anomaly prediction, which leverages a statistical model to determine when users have sufficiently deviated from communities. We further extend CADS into MetaCADS to account for the semantics of subjects (e.g., patients’ diagnoses). To empirically evaluate the framework, we perform an assessment with three months of access logs from a real electronic health record (EHR) system in a large medical center. The results illustrate our models exhibit significant performance gains over state-of-the-art competitors. When the number of illicit users is low, MetaCADS is the best model, but as the number grows, commonly accessed semantics lead to hiding in a crowd, such that CADS is more prudent. PMID:24489520

  3. 75 FR 69644 - Privacy Act of 1974; System of Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-15

    ..., organization, phone, fax, mobile, pager, Defense Switched Network (DSN) phone, other fax, other mobile, other.../Transport Layer Security (SSL/ TLS) connections, access control lists, file system permissions, intrusion detection and prevention systems and log monitoring. Complete access to all records is restricted to and...

  4. Analyzing Decision Logs to Understand Decision Making in Serious Crime Investigations.

    PubMed

    Dando, Coral J; Ormerod, Thomas C

    2017-12-01

    Objective To study decision making by detectives when investigating serious crime through the examination of decision logs to explore hypothesis generation and evidence selection. Background Decision logs are used to record and justify decisions made during serious crime investigations. The complexity of investigative decision making is well documented, as are the errors associated with miscarriages of justice and inquests. The use of decision logs has not been the subject of an empirical investigation, yet they offer an important window into the nature of investigative decision making in dynamic, time-critical environments. Method A sample of decision logs from British police forces was analyzed qualitatively and quantitatively to explore hypothesis generation and evidence selection by police detectives. Results Analyses revealed diversity in documentation of decisions that did not correlate with case type and identified significant limitations of the decision log approach to supporting investigative decision making. Differences emerged between experienced and less experienced officers' decision log records in exploration of alternative hypotheses, generation of hypotheses, and sources of evidential inquiry opened over phase of investigation. Conclusion The practical use of decision logs is highly constrained by their format and context of use. Despite this, decision log records suggest that experienced detectives display strategic decision making to avoid confirmation and satisficing, which affect less experienced detectives. Application Potential applications of this research include both training in case documentation and the development of new decision log media that encourage detectives, irrespective of experience, to generate multiple hypotheses and optimize the timely selection of evidence to test them.

  5. Coagulation, flocculation, dissolved air flotation and filtration in the removal of Giardia spp. and Cryptosporidium spp. from water supply.

    PubMed

    Andreoli, Fernando César; Sabogal-Paz, Lyda Patricia

    2017-11-15

    Removing protozoa from a water supply using coagulation, flocculation, dissolved air flotation (DAF) and filtration on a bench scale was evaluated. Calcium carbonate flocculation with and without immunomagnetic separation (IMS) was chosen to detect Giardia spp. cysts and Cryptosporidium spp. oocysts in the studied samples. The results indicated that DAF removed between 1.31 log and 1.79 log of cysts and between 1.08 log and 1.42 log of oocysts. The performance was lower in filtration, with the removal of 1.07 log-1.44 log for cysts and 0.82 log-0.98 log for oocysts. The coagulation, flocculation, DAF and filtration steps removed more than 2.2 log of cysts and oocysts from the water studied. However, protozoa were detected in the filtered water, even with turbidity values of 0.2 NTU. The recovery of the detection method met the international criteria and was higher when there was no IMS. Including the third acid dissociation in the IMS was critical to improve the performance of the protocol tested. However, there was an increase in the technical and analytical complexity and costs. It was also observed that the efficiency of the treatment was linked to the performance of the selected method of detecting protozoa.

  6. Acoustic Emission and Echo Signal Compensation Techniques Applied to an Ultrasonic Logging-While-Drilling Caliper.

    PubMed

    Yao, Yongchao; Ju, Xiaodong; Lu, Junqiang; Men, Baiyong

    2017-06-10

    A logging-while-drilling (LWD) caliper is a tool used for the real-time measurement of a borehole diameter in oil drilling engineering. This study introduces the mechanical structure and working principle of a new LWD caliper based on ultrasonic distance measurement (UDM). The detection range is a major performance index of a UDM system. This index is determined by the blind zone length and remote reflecting interface detection capability of the system. To reduce the blind zone length and detect near the reflecting interface, a full bridge acoustic emission technique based on bootstrap gate driver (BGD) and metal-oxide-semiconductor field effect transistor (MOSFET) is designed by analyzing the working principle and impedance characteristics of a given piezoelectric transducer. To detect the remote reflecting interface and reduce the dynamic range of the received echo signals, the relationships between the echo amplitude and propagation distance of ultrasonic waves are determined. A signal compensation technique based on time-varying amplification theory, which can automatically change the gain according to the echo arrival time is designed. Lastly, the aforementioned techniques and corresponding circuits are experimentally verified. Results show that the blind zone length in the UDM system of the LWD caliper is significantly reduced and the capability to detect the remote reflecting interface is considerably improved.

  7. Acoustic Emission and Echo Signal Compensation Techniques Applied to an Ultrasonic Logging-While-Drilling Caliper

    PubMed Central

    Yao, Yongchao; Ju, Xiaodong; Lu, Junqiang; Men, Baiyong

    2017-01-01

    A logging-while-drilling (LWD) caliper is a tool used for the real-time measurement of a borehole diameter in oil drilling engineering. This study introduces the mechanical structure and working principle of a new LWD caliper based on ultrasonic distance measurement (UDM). The detection range is a major performance index of a UDM system. This index is determined by the blind zone length and remote reflecting interface detection capability of the system. To reduce the blind zone length and detect near the reflecting interface, a full bridge acoustic emission technique based on bootstrap gate driver (BGD) and metal-oxide-semiconductor field effect transistor (MOSFET) is designed by analyzing the working principle and impedance characteristics of a given piezoelectric transducer. To detect the remote reflecting interface and reduce the dynamic range of the received echo signals, the relationships between the echo amplitude and propagation distance of ultrasonic waves are determined. A signal compensation technique based on time-varying amplification theory, which can automatically change the gain according to the echo arrival time is designed. Lastly, the aforementioned techniques and corresponding circuits are experimentally verified. Results show that the blind zone length in the UDM system of the LWD caliper is significantly reduced and the capability to detect the remote reflecting interface is considerably improved. PMID:28604603

  8. Detection technique for artificially illuminated objects in the outer solar system and beyond.

    PubMed

    Loeb, Abraham; Turner, Edwin L

    2012-04-01

    Existing and planned optical telescopes and surveys can detect artificially illuminated objects, comparable in total brightness to a major terrestrial city, at the outskirts of the Solar System. Orbital parameters of Kuiper belt objects (KBOs) are routinely measured to exquisite precisions of<10(-3). Here, we propose to measure the variation of the observed flux F from such objects as a function of their changing orbital distances D. Sunlight-illuminated objects will show a logarithmic slope α ≡ (d log F/d log D)=-4, whereas artificially illuminated objects should exhibit α=-2. The proposed Large Synoptic Survey Telescope (LSST) and other planned surveys will provide superb data and allow measurement of α for thousands of KBOs. If objects with α=-2 are found, follow-up observations could measure their spectra to determine whether they are illuminated by artificial lighting. The search can be extended beyond the Solar System with future generations of telescopes on the ground and in space that would have the capacity to detect phase modulation due to very strong artificial illumination on the nightside of planets as they orbit their parent stars.

  9. Infrared Drying as a Potential Alternative to Convective Drying for Biltong Production.

    PubMed

    Cherono, Kipchumba; Mwithiga, Gikuru; Schmidt, Stefan

    2016-06-03

    Two infrared systems set at an intensity of 4777 W/m 2 with peak emission wavelengths of 2.5 and 3.5 µm were used to produce biltong by drying differently pre-treated meat. In addition to meat texture and colour, the microbial quality of the biltong produced was assessed by quantifying viable heterotrophic microorganisms using a most probable number (MPN) method and by verifying the presence of presumptive Escherichia coli in samples produced using infrared and conventional convective drying. The two infrared drying systems reduced the heterotrophic microbial burden from 5.11 log 10 MPN/g to 2.89 log 10 MPN/g (2.5 µm) and 3.42 log 10 MPN/g (3.5 µm), respectively. The infrared systems achieved an up to one log higher MPN/g reduction than the convective system. In biltong samples produced by short wavelength (2.5 µm) infrared drying, E. coli was not detectable. This study demonstrates that the use of short wavelength infrared drying is a potential alternative to conventional convective drying by improving the microbiological quality of biltong products while at the same time delivering products of satisfactory quality.

  10. Cosmic dance at z 3: Detecting the host galaxies of the dual AGN system LBQS 0302-0019 and Jil with HAWK-I+GRAAL

    NASA Astrophysics Data System (ADS)

    Husemann, B.; Bielby, R.; Jahnke, K.; Arrigoni-Battaia, F.; Worseck, G.; Shanks, T.; Wardlow, J.; Scholtz, J.

    2018-06-01

    We recently discovered that the luminous radio-quiet quasi-stellar objects (QSO) LBQS 0302-0019 at z = 3.286 is likely accompanied by an obscured AGN at 20 kpc projected distance, which we dubbed Jil. It represents the tightest candidate system of an obscured and unobscured dual AGN at z > 3. To verify the dual AGN scenario, we obtained deep Ks band (rest-frame V band) imaging with the VLT/HAWK-I+GRAAL instrument at 0.″4 resolution during science verification in January 2018. We detect the individual host galaxies of the QSO and Jil with estimated stellar masses of log(M⋆/M⊙) = 11.4 ± 0.5 and log(M⋆/M⊙) = 0.9 ± 0.5, respectively. Near-IR spectra obtained with Very Large Telescope-K-band Multi Object Spectrograph (VLT-KMOS) reveal a clear [O III] λ5007 line detection at the location of Jil that does not contribute significantly to the Ks band flux. Both observations therefore corroborate the dual AGN scenario. A comparison to Illustris simulations suggests a parent halo mass of log(Mhalo/M⊙) = 13.2 ± 0.5 for this interacting galaxy system, corresponding to a massive dark matter halo at that epoch. Based on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere under ESO programme(s) 60.A-9471(A) and 100.A-0134(B).

  11. An in-house assay for BK polyomavirus quantification using the Abbott m2000 RealTime system.

    PubMed

    Muldrew, Kenneth L; Lovett, Jennie L

    2013-11-01

    BK polyomavirus (BKPyV) quantification is useful for monitoring renal transplant patient response to therapy. The Abbott m2000 RealTime System employed by some clinical laboratories to perform US Food and Drug Administration-approved assays can also be used to develop in-house assays such as the one presented here. This study aimed to validate an in-house quantitative real-time PCR assay targeting the BKPyV major capsid VP1 gene for assessment of viral load using the Abbott m2000 RealTime System. BKPyV load was measured in 95 urine and plasma samples previously tested for BKPyV by one of three laboratories (46 BKPyV-positive samples consisting of 35 plasma and 11 urine samples; 49 samples negative for BKPyV consisting of 47 plasma and two urine samples). Two additional plasma specimens from the College of American Pathologists proficiency testing survey were also analysed. Precision studies were performed by diluting a high-viral-titre patient sample into BKPyV-negative pooled plasma to create high-positive (6.16 log10 copies ml(-1)) and low-positive (3.16 log10 copies ml(-1)) samples. For precision studies of inter-assay variability, a high-positive (7.0 log10 copies ml(-1)) and a low-positive (3.0 log10 copies ml(-1)) sample were measured in 20 separate runs. The assay's limit of quantification and limit of detection were 2.70 and 2.25 log10 copies ml(-1), respectively. The assay was linear from 2.70 to 9.26 log10 copies ml(-1). Of the 48 known positives, 43 were detected as positive, with three reported by the reference laboratory as values lower than the limit of detection. Two known positives at 3.27 and 3.80 log10 copies ml(-1) tested negative by the m2000 BKPyV assay. Of the 49 known negative samples, 48 were negative by the m2000 BKPyV load assay, with one sample confirmed positive by a reference laboratory. Qualitative analysis prior to discrepancy testing demonstrated a sensitivity of 89.58 % and a specificity of 97.96 %. Precision studies demonstrated inter-assay coefficients of variation of 0.63 % (high positive) and 4.38 % (low positive). Genotyping was performed on 22 patient samples, of which 21 (95.45 %) were type I and one (4.55 %) was type II. In conclusion, the m2000 BKPyV viral load assay sensitivity, specificity, linear range, precision and cost effectiveness make it an attractive methodology for clinical laboratories using the Abbott m2000 RealTime System.

  12. A new high-precision borehole-temperature logging system used at GISP2, Greenland, and Taylor Dome, Antarctica

    USGS Publications Warehouse

    Clow, G.D.; Saltus, R.W.; Waddington, E.D.

    1996-01-01

    We describe a high-precision (0.1-1.0 mK) borehole-temperature (BT) logging system developed at the United States Geological Survey (USGS) for use in remote polar regions. We discuss calibration, operational and data-processing procedures, and present an analysis of the measurement errors. The system is modular to facilitate calibration procedures and field repairs. By interchanging logging cables and temperature sensors, measurements can be made in either shallow air-filled boreholes or liquid-filled holes up to 7 km deep. Data can be acquired in either incremental or continuous-logging modes. The precision of data collected by the new logging system is high enough to detect and quantify various thermal effects at the milli-Kelvin level. To illustrate this capability, we present sample data from the 3 km deep borehole at GISP2, Greenland, and from a 130m deep air-filled hole at Taylor Dome, Antarctica. The precision of the processed GTSP2 continuous temperature logs is 0.25-0.34 mK, while the accuracy is estimated to be 4.5 mK. The effects of fluid convection and the dissipation of the thermal disturbance caused by drilling the borehole are clearly visible in the data. The precision of the incremental Taylor Dome measurements varies from 0.11 to 0.32mK, depending on the wind strength during the experiments. With this precision, we found that temperature fluctuations and multi-hour trends in the BT measurements correlate well with atmospheric-pressure changes.

  13. Monitoring of microbial hazards at farms, slaughterhouses, and processing lines of swine in Korea.

    PubMed

    Rho, M J; Chung, M S; Lee, J H; Park, J

    2001-09-01

    This study was executed to investigate microbiological hazards at swine farms, slaughterhouses, dressing operations, and local markets for the application of the hazard analysis critical control point system in Korea by analyzing total aerobic plate count (APC) and presence of pathogens. Six integrated pig farms and meat packers were selected from six different provinces, and samples were collected from pig carcasses by swabbing and excision methods at the slaughterhouses, processing rooms, and local markets, respectively. APCs of water in water tanks were relatively low, 1.9 to 3.1 log10 CFU/ml; however, they were increased to 4.6 to 6.9 log10 CFU/ml when sampled from water nipples in the pigpen. APCs of feeds in the feed bins and in the pigpens were 4.4 to 5.4 and 5.2 to 6.7 log10 CFU/g, respectively. Salmonella spp., Staphylococcus aureus, and Clostridium perfringens were detected from water and feed sampled in pigpens and pigpen floors. S. aureus was the most frequently detected pathogenic bacteria in slaughterhouses and processing rooms. Listeria monocytogenes and Yersinia enterocolitica were also detected from the processing rooms of the Kyonggi, Kyongsang, and Cheju provinces. Even though APCs were maintained at the low level of 3.0 log10 CFU/g during slaughtering and processing steps, those of final pork products produced by the same companies showed relatively high numbers when purchased from the local market. These results indicated that the cold chain system for transporting and merchandising of pork products was deficient in Korea. Water supply and feed bins in swine farms and individual operations can be identified as critical control points to reduce microbiological hazards in swine farms, slaughterhouses, and processing plants.

  14. Assessment of the efficacy of the first water system for emergency hospital use.

    PubMed

    Long, Sharon C; Olstadt, Jeremy

    2011-03-01

    The First Water Responder B package water treatment device was evaluated for its ability to reduce the levels of spiked indicators and pathogens (Escherichia coli, MS2 coliphage, murine adenovirus, and Cryptosporidium oocysts) in a surface water to partially evaluate its appropriateness to be used to provide safe drinking water to hospitals during emergency situations. Lake water was collected in 50-L carboys and spiked with selected indicators and pathogens (E coli, MS2 coliphage, murine adenovirus, and Cryptosporidium oocysts) at 2 different spike levels (low and high). This water was treated using the First Water Responder B, and the microorganisms were enumerated before and after treatment using US Environmental Protection Agency and Standard Methods. Microbial removal efficiencies were compared with Environmental Protection Agency guidelines. E coli spikes ranged from 2.9 to 1059 colony-forming units (CFU)/100 mL with removals to below detection limits (1 CFU/100 mL) to 2.8 CFU/100 mL or 0.98 to 3.5 log(10) reductions. MS2 coliphage spikes ranged from 3 plaque-forming units (PFU) to 837 PFU/100 mL with removals to below detection limits (1 PFU/100 mL) to 11.7 PFU/100 mL or 0.65 to 1.9 log(10) reductions. Murine adenovirus spikes ranged from 203 to 8410 most probable number (MPN) of infectious units/100 mL with removals to below detection limits (23 MPN infectious units/100 mL) to 1370 MPN infectious units/100 mL or 0.79 to >1.2 log(10) reductions. Cryptosporidium parvum oocyst spikes ranged from 52 to 853 oocysts per liter with removals to below detection limits (<1 oocyst per liter) to 0.3 oocysts per liter or >2.2 to 3.4 log(10) reductions. Although the First Water system could remove a significant portion of the spiked organisms, it is recommended that this point-of-use system be coupled with chemical disinfection in a multiple-barrier approach to provide water of the highest reasonably achievable quality for hospital use in emergency situations. ©2011 American Medical Association. All rights reserved.

  15. Primary detection of hardwood log defects using laser surface scanning

    Treesearch

    Ed Thomas; Liya Thomas; Lamine Mili; Roger Ehrich; A. Lynn Abbott; Clifford Shaffer; Clifford Shaffer

    2003-01-01

    The use of laser technology to scan hardwood log surfaces for defects holds great promise for improving processing efficiency and the value and volume of lumber produced. External and internal defect detection to optimize hardwood log and lumber processing is one of the top four technological needs in the nation's hardwood industry. The location, type, and...

  16. Transaction aware tape-infrastructure monitoring

    NASA Astrophysics Data System (ADS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-06-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  17. SU-F-T-469: A Clinically Observed Discrepancy Between Image-Based and Log- Based MLC Position

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neal, B; Ahmed, M; Siebers, J

    2016-06-15

    Purpose: To present a clinical case which challenges the base assumption of log-file based QA, by showing that the actual position of a MLC leaf can suddenly deviate from its programmed and logged position by >1 mm as observed with real-time imaging. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used in cine mode to capture portal images during treatment. Visual monitoring identified an anomalous MLC leaf pair gap not otherwise detected by the automatic position verification. The position of the erred leaf was measured on EPID images and log files were analyzed for themore » treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3±0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusion: It has been clinically observed that log-file derived leaf positions can differ from their actual positions by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trusting log file records. Intra-treatment EPID imaging provides a method to capture departures from MLC planned positions. Work was supported in part by Varian Medical Systems.« less

  18. Development and evaluation of a reflective solar disinfection pouch for treatment of drinking water.

    PubMed

    Walker, D Carey; Len, Soo-Voon; Sheehan, Brita

    2004-04-01

    A second-generation solar disinfection (SODIS) system (pouch) was constructed from food-grade, commercially available packaging materials selected to fully transmit and amplify the antimicrobial properties of sunlight. Depending upon the season, water source, and challenge organism, culturable bacteria were reduced between 3.5 and 5.5 log cycles. The system was also capable of reducing the background presumptive coliform population in nonsterile river water below the level of detection. Similar experiments conducted with a model virus, the F-specific RNA bacteriophage MS2, indicated that the pouch was slightly less efficient, reducing viable plaques by 3.5 log units in comparison to a 5.0 log reduction of enterotoxigenic Escherichia coli O18:H11 within the same time period. These results suggest that water of poor microbiological quality can be improved by using a freely available resource (sunlight) and a specifically designed plastic pouch constructed of food-grade packaging materials.

  19. Improved one-dimensional area law for frustration-free systems

    NASA Astrophysics Data System (ADS)

    Arad, Itai; Landau, Zeph; Vazirani, Umesh

    2012-05-01

    We present a new proof for the 1D area law for frustration-free systems with a constant gap, which exponentially improves the entropy bound in Hastingsâ 1D area law and which is tight to within a polynomial factor. For particles of dimension d, spectral gap ɛ>0, and interaction strength at most J, our entropy bound is S1D≤O(1)·X3log8X, where X=def(Jlogd)/ɛ. Our proof is completely combinatorial, combining the detectability lemma with basic tools from approximation theory. In higher dimensions, when the bipartitioning area is |∂L|, we use additional local structure in the proof and show that S≤O(1)·|∂L|2log6|∂L|·X3log8X. This is at the cusp of being nontrivial in the 2D case, in the sense that any further improvement would yield a subvolume law.

  20. Removal of micro-organisms in a small-scale hydroponics wastewater treatment system.

    PubMed

    Ottoson, J; Norström, A; Dalhammar, G

    2005-01-01

    To measure the microbial removal capacity of a small-scale hydroponics wastewater treatment plant. Paired samples were taken from untreated, partly-treated and treated wastewater and analysed for faecal microbial indicators, i.e. coliforms, Escherichia coli, enterococci, Clostridium perfringens spores and somatic coliphages, by culture based methods. Escherichia coli was never detected in effluent water after >5.8-log removal. Enterococci, coliforms, spores and coliphages were removed by 4.5, 4.1, 2.3 and 2.5 log respectively. Most of the removal (60-87%) took place in the latter part of the system because of settling, normal inactivation (retention time 12.7 d) and sand filtration. Time-dependent log-linear removal was shown for spores (k = -0.17 log d(-1), r(2) = 0.99). Hydroponics wastewater treatment removed micro-organisms satisfactorily. Investigations on the microbial removal capacity of hydroponics have only been performed for bacterial indicators. In this study it has been shown that virus and (oo)cyst process indicators were removed and that hydroponics can be an alternative to conventional wastewater treatment.

  1. Multi-Sensor Systems Development for UXO Detection and Discrimination: Hand-Held Dual Magnetic/Electromagnetic Induction Sensor

    DTIC Science & Technology

    2008-04-01

    5 Fluxgate magnetometer ... magnetometer into digital format, and transmitted as a single serial data string to log the Cs and fluxgate magnetometer data. After procurement...Hardware The system hardware comprises an EMI sensor, Cs vapor magnetometer , fluxgate magnetometer , hand-held data acquisition computer, integrated

  2. 75 FR 16123 - Dave & Buster’s, Inc.; Analysis of Proposed Consent Order to Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-31

    ... computer networks or to conduct security investigations, such as by employing an intrusion detection system and monitoring system logs; (b) failed to adequately restrict third-party access to its networks, such... reasonable and appropriate security for personal information on its computer networks. Among other things...

  3. Defect detection on hardwood logs using high resolution three-dimensional laser scan data

    Treesearch

    Liya Thomas; Lamine Mili; Clifford A. Shaffer; Ed Thomas; Ed Thomas

    2004-01-01

    The location, type, and severity of external defects on hardwood logs and skills are the primary indicators of overall log quality and value. External defects provide hints about the internal log characteristics. Defect data would improve the sawyer's ability to process logs such that a higher valued product (lumber) is generated. Using a high-resolution laser log...

  4. 22nd Annual Logistics Conference and Exhibition

    DTIC Science & Technology

    2006-04-20

    Prognostics & Health Management at GE Dr. Piero P.Bonissone Industrial AI Lab GE Global Research NCD Select detection model Anomaly detection results...Mode 213 x Failure mode histogram 2130014 Anomaly detection from event-log data Anomaly detection from event-log data Diagnostics/ Prognostics Using...Failure Monitoring & AssessmentTactical C4ISR Sense Respond 7 •Diagnostics, Prognostics and health management

  5. A Quantitative Experimental Study of the Effectiveness of Systems to Identify Network Attackers

    ERIC Educational Resources Information Center

    Handorf, C. Russell

    2016-01-01

    This study analyzed the meta-data collected from a honeypot that was run by the Federal Bureau of Investigation for a period of 5 years. This analysis compared the use of existing industry methods and tools, such as Intrusion Detection System alerts, network traffic flow and system log traffic, within the Open Source Security Information Manager…

  6. A rapidly equilibrating, thin film, passive water sampler for organic contaminants; characterization and field testing.

    PubMed

    St George, Tiffany; Vlahos, Penny; Harner, Tom; Helm, Paul; Wilford, Bryony

    2011-02-01

    Improving methods for assessing the spatial and temporal resolution of organic compound concentrations in marine environments is important to the sustainable management of our coastal systems. Here we evaluate the use of ethylene vinyl acetate (EVA) as a candidate polymer for thin-film passive sampling in waters of marine environments. Log K(EVA-W) partition coefficients correlate well (r(2) = 0.87) with Log K(OW) values for selected pesticides and polychlorinated biphenyls (PCBs) where Log K(EVA-W) = 1.04 Log K(OW) + 0.22. EVA is a suitable polymer for passive sampling due to both its high affinity for organic compounds and its ease of coating at sub-micron film thicknesses on various substrates. Twelve-day field deployments were effective in detecting target compounds with good precision making EVA a potential multi-media fugacity meter. Published by Elsevier Ltd.

  7. SU-E-T-392: Evaluation of Ion Chamber/film and Log File Based QA to Detect Delivery Errors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, C; Mason, B; Kirsner, S

    2015-06-15

    Purpose: Ion chamber and film (ICAF) is a method used to verify patient dose prior to treatment. More recently, log file based QA has been shown as an alternative for measurement based QA. In this study, we delivered VMAT plans with and without errors to determine if ICAF and/or log file based QA was able to detect the errors. Methods: Using two VMAT patients, the original treatment plan plus 7 additional plans with delivery errors introduced were generated and delivered. The erroneous plans had gantry, collimator, MLC, gantry and collimator, collimator and MLC, MLC and gantry, and gantry, collimator, andmore » MLC errors. The gantry and collimator errors were off by 4{sup 0} for one of the two arcs. The MLC error introduced was one in which the opening aperture didn’t move throughout the delivery of the field. For each delivery, an ICAF measurement was made as well as a dose comparison based upon log files. Passing criteria to evaluate the plans were ion chamber less and 5% and film 90% of pixels pass the 3mm/3% gamma analysis(GA). For log file analysis 90% of voxels pass the 3mm/3% 3D GA and beam parameters match what was in the plan. Results: Two original plans were delivered and passed both ICAF and log file base QA. Both ICAF and log file QA met the dosimetry criteria on 4 of the 12 erroneous cases analyzed (2 cases were not analyzed). For the log file analysis, all 12 erroneous plans alerted a mismatch in delivery versus what was planned. The 8 plans that didn’t meet criteria all had MLC errors. Conclusion: Our study demonstrates that log file based pre-treatment QA was able to detect small errors that may not be detected using an ICAF and both methods of were able to detect larger delivery errors.« less

  8. Performance analysis of MISO multi-hop FSO links over log-normal channels with fog and beam divergence attenuations

    NASA Astrophysics Data System (ADS)

    Abaza, Mohamed; Mesleh, Raed; Mansour, Ali; Aggoune, el-Hadi

    2015-01-01

    The performance analysis of a multi-hop decode and forward relaying free-space optical (FSO) communication system is presented in this paper. The considered FSO system uses intensity modulation and direct detection as means of transmission and reception. Atmospheric turbulence impacts are modeled as a log-normal channel, and different weather attenuation effects and geometric losses are taken into account. It is shown that multi-hop is an efficient technique to mitigate such effects in FSO communication systems. A comparison with direct link and multiple-input single-output (MISO) systems considering correlation effects at the transmitter is provided. Results show that MISO multi-hop FSO systems are superior than their counterparts over links exhibiting high attenuation. Monte Carlo simulation results are provided to validate the bit error rate (BER) analyses and conclusions.

  9. Matching disease and phenotype ontologies in the ontology alignment evaluation initiative.

    PubMed

    Harrow, Ian; Jiménez-Ruiz, Ernesto; Splendiani, Andrea; Romacker, Martin; Woollard, Peter; Markel, Scott; Alam-Faruque, Yasmin; Koch, Martin; Malone, James; Waaler, Arild

    2017-12-02

    The disease and phenotype track was designed to evaluate the relative performance of ontology matching systems that generate mappings between source ontologies. Disease and phenotype ontologies are important for applications such as data mining, data integration and knowledge management to support translational science in drug discovery and understanding the genetics of disease. Eleven systems (out of 21 OAEI participating systems) were able to cope with at least one of the tasks in the Disease and Phenotype track. AML, FCA-Map, LogMap(Bio) and PhenoMF systems produced the top results for ontology matching in comparison to consensus alignments. The results against manually curated mappings proved to be more difficult most likely because these mapping sets comprised mostly subsumption relationships rather than equivalence. Manual assessment of unique equivalence mappings showed that AML, LogMap(Bio) and PhenoMF systems have the highest precision results. Four systems gave the highest performance for matching disease and phenotype ontologies. These systems coped well with the detection of equivalence matches, but struggled to detect semantic similarity. This deserves more attention in the future development of ontology matching systems. The findings of this evaluation show that such systems could help to automate equivalence matching in the workflow of curators, who maintain ontology mapping services in numerous domains such as disease and phenotype.

  10. Fast and objective detection and analysis of structures in downhole images

    NASA Astrophysics Data System (ADS)

    Wedge, Daniel; Holden, Eun-Jung; Dentith, Mike; Spadaccini, Nick

    2017-09-01

    Downhole acoustic and optical televiewer images, and formation microimager (FMI) logs are important datasets for structural and geotechnical analyses for the mineral and petroleum industries. Within these data, dipping planar structures appear as sinusoids, often in incomplete form and in abundance. Their detection is a labour intensive and hence expensive task and as such is a significant bottleneck in data processing as companies may have hundreds of kilometres of logs to process each year. We present an image analysis system that harnesses the power of automated image analysis and provides an interactive user interface to support the analysis of televiewer images by users with different objectives. Our algorithm rapidly produces repeatable, objective results. We have embedded it in an interactive workflow to complement geologists' intuition and experience in interpreting data to improve efficiency and assist, rather than replace the geologist. The main contributions include a new image quality assessment technique for highlighting image areas most suited to automated structure detection and for detecting boundaries of geological zones, and a novel sinusoid detection algorithm for detecting and selecting sinusoids with given confidence levels. Further tools are provided to perform rapid analysis of and further detection of structures e.g. as limited to specific orientations.

  11. A multi-data source surveillance system to detect a bioterrorism attack during the G8 Summit in Scotland.

    PubMed

    Meyer, N; McMenamin, J; Robertson, C; Donaghy, M; Allardice, G; Cooper, D

    2008-07-01

    In 18 weeks, Health Protection Scotland (HPS) deployed a syndromic surveillance system to early-detect natural or intentional disease outbreaks during the G8 Summit 2005 at Gleneagles, Scotland. The system integrated clinical and non-clinical datasets. Clinical datasets included Accident & Emergency (A&E) syndromes, and General Practice (GPs) codes grouped into syndromes. Non-clinical data included telephone calls to a nurse helpline, laboratory test orders, and hotel staff absenteeism. A cumulative sum-based detection algorithm and a log-linear regression model identified signals in the data. The system had a fax-based track for real-time identification of unusual presentations. Ninety-five signals were triggered by the detection algorithms and four forms were faxed to HPS. Thirteen signals were investigated. The system successfully complemented a traditional surveillance system in identifying a small cluster of gastroenteritis among the police force and triggered interventions to prevent further cases.

  12. 10 CFR 39.69 - Radioactive contamination control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.69 Radioactive contamination control. (a) If the licensee detects... licensee shall continuously monitor, with an appropriate radiation detection instrument or a logging tool...

  13. 10 CFR 39.69 - Radioactive contamination control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.69 Radioactive contamination control. (a) If the licensee detects... licensee shall continuously monitor, with an appropriate radiation detection instrument or a logging tool...

  14. 10 CFR 39.69 - Radioactive contamination control.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.69 Radioactive contamination control. (a) If the licensee detects... licensee shall continuously monitor, with an appropriate radiation detection instrument or a logging tool...

  15. 10 CFR 39.69 - Radioactive contamination control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.69 Radioactive contamination control. (a) If the licensee detects... licensee shall continuously monitor, with an appropriate radiation detection instrument or a logging tool...

  16. 10 CFR 39.69 - Radioactive contamination control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.69 Radioactive contamination control. (a) If the licensee detects... licensee shall continuously monitor, with an appropriate radiation detection instrument or a logging tool...

  17. Detection Technique for Artificially Illuminated Objects in the Outer Solar System and Beyond

    PubMed Central

    Loeb, Abraham

    2012-01-01

    Abstract Existing and planned optical telescopes and surveys can detect artificially illuminated objects, comparable in total brightness to a major terrestrial city, at the outskirts of the Solar System. Orbital parameters of Kuiper belt objects (KBOs) are routinely measured to exquisite precisions of<10−3. Here, we propose to measure the variation of the observed flux F from such objects as a function of their changing orbital distances D. Sunlight-illuminated objects will show a logarithmic slope α ≡ (d log F/d log D)=−4, whereas artificially illuminated objects should exhibit α=−2. The proposed Large Synoptic Survey Telescope (LSST) and other planned surveys will provide superb data and allow measurement of α for thousands of KBOs. If objects with α=−2 are found, follow-up observations could measure their spectra to determine whether they are illuminated by artificial lighting. The search can be extended beyond the Solar System with future generations of telescopes on the ground and in space that would have the capacity to detect phase modulation due to very strong artificial illumination on the nightside of planets as they orbit their parent stars. Key Words: Astrobiology—SETI—Kuiper belt objects—Artificial illumination. Astrobiology 12, 290–294. PMID:22490065

  18. Leak checker data logging system

    DOEpatents

    Gannon, J.C.; Payne, J.J.

    1996-09-03

    A portable, high speed, computer-based data logging system for field testing systems or components located some distance apart employs a plurality of spaced mass spectrometers and is particularly adapted for monitoring the vacuum integrity of a long string of a superconducting magnets such as used in high energy particle accelerators. The system provides precise tracking of a gas such as helium through the magnet string when the helium is released into the vacuum by monitoring the spaced mass spectrometers allowing for control, display and storage of various parameters involved with leak detection and localization. A system user can observe the flow of helium through the magnet string on a real-time basis hour the exact moment of opening of the helium input valve. Graph reading can be normalized to compensate for magnet sections that deplete vacuum faster than other sections between testing to permit repetitive testing of vacuum integrity in reduced time. 18 figs.

  19. Leak checker data logging system

    DOEpatents

    Gannon, Jeffrey C.; Payne, John J.

    1996-01-01

    A portable, high speed, computer-based data logging system for field testing systems or components located some distance apart employs a plurality of spaced mass spectrometers and is particularly adapted for monitoring the vacuum integrity of a long string of a superconducting magnets such as used in high energy particle accelerators. The system provides precise tracking of a gas such as helium through the magnet string when the helium is released into the vacuum by monitoring the spaced mass spectrometers allowing for control, display and storage of various parameters involved with leak detection and localization. A system user can observe the flow of helium through the magnet string on a real-time basis hour the exact moment of opening of the helium input valve. Graph reading can be normalized to compensate for magnet sections that deplete vacuum faster than other sections between testing to permit repetitive testing of vacuum integrity in reduced time.

  20. Epileptic Seizure Detection with Log-Euclidean Gaussian Kernel-Based Sparse Representation.

    PubMed

    Yuan, Shasha; Zhou, Weidong; Wu, Qi; Zhang, Yanli

    2016-05-01

    Epileptic seizure detection plays an important role in the diagnosis of epilepsy and reducing the massive workload of reviewing electroencephalography (EEG) recordings. In this work, a novel algorithm is developed to detect seizures employing log-Euclidean Gaussian kernel-based sparse representation (SR) in long-term EEG recordings. Unlike the traditional SR for vector data in Euclidean space, the log-Euclidean Gaussian kernel-based SR framework is proposed for seizure detection in the space of the symmetric positive definite (SPD) matrices, which form a Riemannian manifold. Since the Riemannian manifold is nonlinear, the log-Euclidean Gaussian kernel function is applied to embed it into a reproducing kernel Hilbert space (RKHS) for performing SR. The EEG signals of all channels are divided into epochs and the SPD matrices representing EEG epochs are generated by covariance descriptors. Then, the testing samples are sparsely coded over the dictionary composed by training samples utilizing log-Euclidean Gaussian kernel-based SR. The classification of testing samples is achieved by computing the minimal reconstructed residuals. The proposed method is evaluated on the Freiburg EEG dataset of 21 patients and shows its notable performance on both epoch-based and event-based assessments. Moreover, this method handles multiple channels of EEG recordings synchronously which is more speedy and efficient than traditional seizure detection methods.

  1. Nondestructive Methods for Detecting Defects in Softwood Logs

    Treesearch

    Kristin C. Schad; Daniel L. Schmoldt; Robert J. Ross

    1996-01-01

    Wood degradation and defects, such as voids and knots, affect the quality and processing time of lumber. The ability to detect internal defects in the log can save mills time and processing costs. In this study, we investigated three nondestructive evaluation techniques for detecting internal wood defects. Sound wave transmission, x-ray computed tomography, and impulse...

  2. Development and Evaluation of a Reflective Solar Disinfection Pouch for Treatment of Drinking Water

    PubMed Central

    Walker, D. Carey; Len, Soo-Voon; Sheehan, Brita

    2004-01-01

    A second-generation solar disinfection (SODIS) system (pouch) was constructed from food-grade, commercially available packaging materials selected to fully transmit and amplify the antimicrobial properties of sunlight. Depending upon the season, water source, and challenge organism, culturable bacteria were reduced between 3.5 and 5.5 log cycles. The system was also capable of reducing the background presumptive coliform population in nonsterile river water below the level of detection. Similar experiments conducted with a model virus, the F-specific RNA bacteriophage MS2, indicated that the pouch was slightly less efficient, reducing viable plaques by 3.5 log units in comparison to a 5.0 log reduction of enterotoxigenic Escherichia coli O18:H11 within the same time period. These results suggest that water of poor microbiological quality can be improved by using a freely available resource (sunlight) and a specifically designed plastic pouch constructed of food-grade packaging materials. PMID:15066858

  3. Lumber value differences from reduced CT spatial resolution and simulated log sawing

    Treesearch

    Suraphan Thawornwong; Luis G. Occena; Daniel L. Schmoldt

    2003-01-01

    In the past few years, computed tomography (CT) scanning technology has been applied to the detection of internal defects in hardwood logs for the purpose of obtaining a priori information that can be used to arrive at better log sawing decisions. Because sawyers currently cannot even see the inside of a log until the log faces are revealed by sawing, there is little...

  4. Improved security monitoring method for network bordary

    NASA Astrophysics Data System (ADS)

    Gao, Liting; Wang, Lixia; Wang, Zhenyan; Qi, Aihua

    2013-03-01

    This paper proposes a network bordary security monitoring system based on PKI. The design uses multiple safe technologies, analysis deeply the association between network data flow and system log, it can detect the intrusion activities and position invasion source accurately in time. The experiment result shows that it can reduce the rate of false alarm or missing alarm of the security incident effectively.

  5. Impact detection and analysis/health monitoring system for composites

    NASA Astrophysics Data System (ADS)

    Child, James E.; Kumar, Amrita; Beard, Shawn; Qing, Peter; Paslay, Don G.

    2006-05-01

    This manuscript includes information from test evaluations and development of a smart event detection system for use in monitoring composite rocket motor cases for damaging impacts. The primary purpose of the system as a sentry for case impact event logging is accomplished through; implementation of a passive network of miniaturized piezoelectric sensors, logger with pre-determined force threshold levels, and analysis software. Empirical approaches to structural characterizations and network calibrations along with implementation techniques were successfully evaluated, testing was performed on both unloaded (less propellants) as well as loaded rocket motors with the cylindrical areas being of primary focus. The logged test impact data with known physical network parameters provided for impact location as well as force determination, typically within 3 inches of actual impact location using a 4 foot network grid and force accuracy within 25%of an actual impact force. The simplistic empirical characterization approach along with the robust / flexible sensor grids and battery operated portable logger show promise of a system that can increase confidence in composite integrity for both new assets progressing through manufacturing processes as well as existing assets that may be in storage or transportation.

  6. Study of Magnitudes, Seismicity and Earthquake Detectability Using a Global Network

    DTIC Science & Technology

    1984-06-01

    Ings. the stations are then further classified into three groups: j . A Stations reporting a P-detection with an associated log(A/ T ) value (V...detections, nondetections and reported log(A/ T ) values for the j’th event. given that Its true magnitude is/u j . where t .-. ( + j )1J jL (4) Aj~~ -.Q’ +Qj...subset for which I., ’. % , ILriLI-W I tT W W9 .11mtl’%r’ vl.:", Q -A -Pk,7,W-W ’ dW .P ,[ J -4-- log(A/ T ) was reported. As a first order approximation

  7. Profiler-2000: Attacking the Insider Threat

    DTIC Science & Technology

    2005-09-01

    detection approach and its incorporation into a number of current automated intrusion-detection strategies (e.g., AT&T’s Com- puterWatch, SRI’s Emerald ...administrative privileges, to be activated upon his or her next login . The system calls required to implement this method are chmod and exit. These two calls...kinds of information that can be derived from these (and other) logs are: time of login , physical location of login , duration of user session

  8. SU-F-T-288: Impact of Trajectory Log Files for Clarkson-Based Independent Dose Verification of IMRT and VMAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takahashi, R; Kamima, T; Tachibana, H

    2016-06-15

    Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dosemore » deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less

  9. Reduced density due to logging and its consequences on mating system and pollen flow in the African mahogany Entandrophragma cylindricum.

    PubMed

    Lourmas, M; Kjellberg, F; Dessard, H; Joly, H I; Chevallier, M-H

    2007-08-01

    In tropical forests, selective logging removes large trees that are often the main contributors to pollination. We studied pollination patterns of the African mahogany, Entandrophragma cylindricum (Sapelli). We investigated two plots in Cameroon corresponding to three tree densities: unlogged forest (Ndama 2002), a mildly logged forest 1 year after logging (Ndama 2003) and a severely logged forest 30 years after logging (Dimako). We used four microsatellite markers to perform paternity analysis. Selfing remained below 2% in all treatments. Pollen flow was mainly long distance but with some proximity effects. Average observed within-plot pollination distances were 338, 266 and 385 m, and pollination by trees outside the plots was 70% (Ndama 2002), 74% (Ndama 2003) and 66% (Dimako). Despite sampling a limited number of seeds from a limited number of mother trees, we obtained seeds sired by 35.6-38.3% of the potential within-plot pollen donors. While trees 20 cm in diameter contributed to pollination, results in Dimako suggest that individual larger trees contribute more to pollination than small ones. This effect was not detected in the other treatments. The results suggest extensive pollen flow in Sapelli. Hence, in Sapelli, the main limiting factor for regeneration after logging may be a reduction in the number of trees capable of producing seeds rather genetic effects due to limits to pollen dispersal.

  10. A clinically observed discrepancy between image-based and log-based MLC positions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neal, Brian, E-mail: bpn2p@virginia.edu; Ahmed, Mahmoud; Kathuria, Kunal

    2016-06-15

    Purpose: To present a clinical case in which real-time intratreatment imaging identified an multileaf collimator (MLC) leaf to be consistently deviating from its programmed and logged position by >1 mm. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used to capture cine during treatment images. The author serendipitously visually identified a suspected MLC leaf displacement that was not otherwise detected. The leaf position as recorded on the EPID images was measured and log-files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days.more » Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log-file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3 ± 0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusions: It has been clinically observed that log-file derived leaf positions can differ from their actual position by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trust log-file records. Intratreatment EPID imaging provides a method to capture departures from MLC planned positions.« less

  11. USGS Polar Temperature Logging System, Description and Measurement Uncertainties

    USGS Publications Warehouse

    Clow, Gary D.

    2008-01-01

    This paper provides an updated technical description of the USGS Polar Temperature Logging System (PTLS) and a complete assessment of the measurement uncertainties. This measurement system is used to acquire subsurface temperature data for climate-change detection in the polar regions and for reconstructing past climate changes using the 'borehole paleothermometry' inverse method. Specifically designed for polar conditions, the PTLS can measure temperatures as low as -60 degrees Celsius with a sensitivity ranging from 0.02 to 0.19 millikelvin (mK). A modular design allows the PTLS to reach depths as great as 4.5 kilometers with a skid-mounted winch unit or 650 meters with a small helicopter-transportable unit. The standard uncertainty (uT) of the ITS-90 temperature measurements obtained with the current PTLS range from 3.0 mK at -60 degrees Celsius to 3.3 mK at 0 degrees Celsius. Relative temperature measurements used for borehole paleothermometry have a standard uncertainty (urT) whose upper limit ranges from 1.6 mK at -60 degrees Celsius to 2.0 mK at 0 degrees Celsius. The uncertainty of a temperature sensor's depth during a log depends on specific borehole conditions and the temperature near the winch and thus must be treated on a case-by-case basis. However, recent experience indicates that when logging conditions are favorable, the 4.5-kilometer system is capable of producing depths with a standard uncertainty (uZ) on the order of 200-250 parts per million.

  12. Novel Desorber for Online Drilling Mud Gas Logging.

    PubMed

    Lackowski, Marcin; Tobiszewski, Marek; Namieśnik, Jacek

    2016-01-01

    This work presents the construction solution and experimental results of a novel desorber for online drilling mud gas logging. The traditional desorbers use mechanical mixing of the liquid to stimulate transfer of hydrocarbons to the gaseous phase that is further analyzed. The presented approach is based on transfer of hydrocarbons from the liquid to the gas bubbles flowing through it and further gas analysis. The desorber was checked for gas logging from four different drilling muds collected from Polish boreholes. The results of optimization studies are also presented in this study. The comparison of the novel desorber with a commercial one reveals strong advantages of the novel one. It is characterized by much better hydrocarbons recovery efficiency and allows reaching lower limits of detection of the whole analytical system. The presented desorber seems to be very attractive alternative over widely used mechanical desorbers.

  13. Clinical impact of dosimetric changes for volumetric modulated arc therapy in log file-based patient dose calculations.

    PubMed

    Katsuta, Yoshiyuki; Kadoya, Noriyuki; Fujita, Yukio; Shimizu, Eiji; Matsunaga, Kenichi; Matsushita, Haruo; Majima, Kazuhiro; Jingu, Keiichi

    2017-10-01

    A log file-based method cannot detect dosimetric changes due to linac component miscalibration because log files are insensitive to miscalibration. Herein, clinical impacts of dosimetric changes on a log file-based method were determined. Five head-and-neck and five prostate plans were applied. Miscalibration-simulated log files were generated by inducing a linac component miscalibration into the log file. Miscalibration magnitudes for leaf, gantry, and collimator at the general tolerance level were ±0.5mm, ±1°, and ±1°, respectively, and at a tighter tolerance level achievable on current linac were ±0.3mm, ±0.5°, and ±0.5°, respectively. Re-calculations were performed on patient anatomy using log file data. Changes in tumor control probability/normal tissue complication probability from treatment planning system dose to re-calculated dose at the general tolerance level was 1.8% on planning target volume (PTV) and 2.4% on organs at risk (OARs) in both plans. These changes at the tighter tolerance level were improved to 1.0% on PTV and to 1.5% on OARs, with a statistically significant difference. We determined the clinical impacts of dosimetric changes on a log file-based method using a general tolerance level and a tighter tolerance level for linac miscalibration and found that a tighter tolerance level significantly improved the accuracy of the log file-based method. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. A scale-invariant keypoint detector in log-polar space

    NASA Astrophysics Data System (ADS)

    Tao, Tao; Zhang, Yun

    2017-02-01

    The scale-invariant feature transform (SIFT) algorithm is devised to detect keypoints via the difference of Gaussian (DoG) images. However, the DoG data lacks the high-frequency information, which can lead to a performance drop of the algorithm. To address this issue, this paper proposes a novel log-polar feature detector (LPFD) to detect scale-invariant blubs (keypoints) in log-polar space, which, in contrast, can retain all the image information. The algorithm consists of three components, viz. keypoint detection, descriptor extraction and descriptor matching. Besides, the algorithm is evaluated in detecting keypoints from the INRIA dataset by comparing with the SIFT algorithm and one of its fast versions, the speed up robust features (SURF) algorithm in terms of three performance measures, viz. correspondences, repeatability, correct matches and matching score.

  15. Detection of ICG at low concentrations by photoacoustic imaging system using LED light source

    NASA Astrophysics Data System (ADS)

    Shigeta, Yusuke; Agano, Toshitaka; Sato, Naoto; Nakatsuka, Hitoshi; Kitagawa, Kazuo; Hanaoka, Takamitsu; Morisono, Koji; Tanaka, Chizuyo

    2017-03-01

    Recently, various type of photoacoustic imaging (PAI) that can visualize properties and distribution of light absorber have been researched. We developed PAI system using LED light source and evaluated characteristics of photoacoustic signal intensity versus Indocyanine Green (ICG) concentration. In this experiment, a linear type PZT array transducer (128-elements, 10.0MHz center frequency) was used to be able to transmit and receive ultrasound and also detect photoacoustic signal from the target object. The transducer was connected to the PAI system, and two sets of LED light source that had 850nm wavelength chip array were set to the both side of the transducer. The transducer head was placed at a distance of 20 mm from the target in the water bath. The target object was a tube filled with ICG in it. The tubes containing ICG at concentrations from 300nanomolar to 3millimolar were made by diluting original ICG solution. We measured the photoacoustic signal strength from RF signal generated from the ICG in the tube, and the results showed that the intensity of the signal was almost linear response to the concentration in log-log scale.

  16. Examining the Return on Investment of a Security Information and Event Management Solution in a Notional Department of Defense Network Environment

    DTIC Science & Technology

    2013-06-01

    collection are the facts that devices the lack encryption or compression methods and that the log file must be saved on the host system prior to transfer...time. Statistical correlation utilizes numerical algorithms to detect deviations from normal event levels and other routine activities (Chuvakin...can also assist in detecting low volume threats. Although easy and logical to implement, the implementation of statistical correlation algorithms

  17. European Multicenter Study on Analytical Performance of Veris HIV-1 Assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kalus, Ulrich; Lombardi, Alessandra; Marcos, Maria Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-07-01

    The analytical performance of the Veris HIV-1 assay for use on the new, fully automated Beckman Coulter DxN Veris molecular diagnostics system was evaluated at 10 European virology laboratories. The precision, analytical sensitivity, performance with negative samples, linearity, and performance with HIV-1 groups/subtypes were evaluated. The precision for the 1-ml assay showed a standard deviation (SD) of 0.14 log 10 copies/ml or less and a coefficient of variation (CV) of ≤6.1% for each level tested. The 0.175-ml assay showed an SD of 0.17 log 10 copies/ml or less and a CV of ≤5.2% for each level tested. The analytical sensitivities determined by probit analysis were 19.3 copies/ml for the 1-ml assay and 126 copies/ml for the 0.175-ml assay. The performance with 1,357 negative samples demonstrated 99.2% with not detected results. Linearity using patient samples was shown from 1.54 to 6.93 log 10 copies/ml. The assay performed well, detecting and showing linearity with all HIV-1 genotypes tested. The Veris HIV-1 assay demonstrated analytical performance comparable to that of currently marketed HIV-1 assays. (DxN Veris products are Conformité Européenne [CE]-marked in vitro diagnostic products. The DxN Veris product line has not been submitted to the U.S. FDA and is not available in the U.S. market. The DxN Veris molecular diagnostics system is also known as the Veris MDx molecular diagnostics system and the Veris MDx system.). Copyright © 2017 American Society for Microbiology.

  18. Ontogenetic improvement of visual function in the medaka Oryzias latipes based on an optomotor testing system for larval and adult fish

    USGS Publications Warehouse

    Carvalho, Paulo S. M.; Noltie, Douglas B.; Tillitt, D.E.

    2002-01-01

    We developed a system for evaluation of visual function in larval and adult fish. Both optomotor (swimming) and optokinetic (eye movement) responses were monitored and recorded using a system of rotating stripes. The system allowed manipulation of factors such as width of the stripes used, rotation speed of the striped drum, and light illuminance levels within both the scotopic and photopic ranges. Precise control of these factors allowed quantitative measurements of visual acuity and motion detection. Using this apparatus, we tested the hypothesis that significant posthatch ontogenetic improvements in visual function occur in the medaka Oryzias latipes, and also that this species shows significant in ovo neuronal development. Significant improvements in the acuity angle alpha (ability to discriminate detail) were observed from approximately 5 degrees at hatch to 1 degree in the oldest adult stages. In addition, we measured a significant improvement in flicker fusion thresholds (motion detection skills) between larval and adult life stages within both the scotopic and photopic ranges of light illuminance. Ranges of flicker fusion thresholds (X±SD) at log I=1.96 (photopic) varied from 37.2±1.6 cycles/s in young adults to 18.6±1.6 cycles/s in young larvae 10 days posthatch. At log I=−2.54 (scotopic), flicker fusion thresholds varied from 5.8±0.7 cycles/s in young adults to 1.7±0.4 cycles/s in young larvae 10 days posthatch. Light sensitivity increased approximately 2.9 log units from early hatched larval stages to adults. The demonstrated ontogenetic improvements in visual function probably enable the fish to explore new resources, thereby enlarging their fundamental niche.

  19. Low-Cost Evaluation of EO-1 Hyperion and ALI for Detection and Biophysical Characterization of Forest Logging in Amazonia (NCC5-481)

    NASA Technical Reports Server (NTRS)

    Asner, Gregory P.; Keller, Michael M.; Silva, Jose Natalino; Zweede, Johan C.; Pereira, Rodrigo, Jr.

    2002-01-01

    Major uncertainties exist regarding the rate and intensity of logging in tropical forests worldwide: these uncertainties severely limit economic, ecological, and biogeochemical analyses of these regions. Recent sawmill surveys in the Amazon region of Brazil show that the area logged is nearly equal to total area deforested annually, but conversion of survey data to forest area, forest structural damage, and biomass estimates requires multiple assumptions about logging practices. Remote sensing could provide an independent means to monitor logging activity and to estimate the biophysical consequences of this land use. Previous studies have demonstrated that the detection of logging in Amazon forests is difficult and no studies have developed either the quantitative physical basis or remote sensing approaches needed to estimate the effects of various logging regimes on forest structure. A major reason for these limitations has been a lack of sufficient, well-calibrated optical satellite data, which in turn, has impeded the development and use of physically-based, quantitative approaches for detection and structural characterization of forest logging regimes. We propose to use data from the EO-1 Hyperion imaging spectrometer to greatly increase our ability to estimate the presence and structural attributes of selective logging in the Amazon Basin. Our approach is based on four "biogeophysical indicators" not yet derived simultaneously from any satellite sensor: 1) green canopy leaf area index; 2) degree of shadowing; 3) presence of exposed soil and; 4) non-photosynthetic vegetation material. Airborne, field and modeling studies have shown that the optical reflectance continuum (400-2500 nm) contains sufficient information to derive estimates of each of these indicators. Our ongoing studies in the eastern Amazon basin also suggest that these four indicators are sensitive to logging intensity. Satellite-based estimates of these indicators should provide a means to quantify both the presence and degree of structural disturbance caused by various logging regimes. Our quantitative assessment of Hyperion hyperspectral and ALI multi-spectral data for the detection and structural characterization of selective logging in Amazonia will benefit from data collected through an ongoing project run by the Tropical Forest Foundation, within which we have developed a study of the canopy and landscape biophysics of conventional and reduced-impact logging. We will add to our base of forest structural information in concert with an EO-1 overpass. Using a photon transport model inversion technique that accounts for non-linear mixing of the four biogeophysical indicators, we will estimate these parameters across a gradient of selective logging intensity provided by conventional and reduced impact logging sites. We will also compare our physical ly-based approach to both conventional (e.g., NDVI) and novel (e.g., SWIR-channel) vegetation indices as well as to linear mixture modeling methods. We will cross-compare these approaches using Hyperion and ALI imagers to determine the strengths and limitations of these two sensors for applications of forest biophysics. This effort will yield the first physical ly-based, quantitative analysis of the detection and intensity of selective logging in Amazonia, comparing hyperspectral and improved multi-spectral approaches as well as inverse modeling, linear mixture modeling, and vegetation index techniques.

  20. SU-G-JeP1-08: Dual Modality Verification for Respiratory Gating Using New Real- Time Tumor Tracking Radiotherapy System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shiinoki, T; Hanazawa, H; Shibuya, K

    Purpose: The respirato ry gating system combined the TrueBeam and a new real-time tumor-tracking radiotherapy system (RTRT) was installed. The RTRT system consists of two x-ray tubes and color image intensifiers. Using fluoroscopic images, the fiducial marker which was implanted near the tumor was tracked and was used as the internal surrogate for respiratory gating. The purposes of this study was to develop the verification technique of the respiratory gating with the new RTRT using cine electronic portal image device images (EPIDs) of TrueBeam and log files of the RTRT. Methods: A patient who underwent respiratory gated SBRT of themore » lung using the RTRT were enrolled in this study. For a patient, the log files of three-dimensional coordinate of fiducial marker used as an internal surrogate were acquired using the RTRT. Simultaneously, the cine EPIDs were acquired during respiratory gated radiotherapy. The data acquisition was performed for one field at five sessions during the course of SBRT. The residual motion errors were calculated using the log files (E{sub log}). The fiducial marker used as an internal surrogate into the cine EPIDs was automatically extracted by in-house software based on the template-matching algorithm. The differences between the the marker positions of cine EPIDs and digitally reconstructed radiograph were calculated (E{sub EPID}). Results: Marker detection on EPID using in-house software was influenced by low image contrast. For one field during the course of SBRT, the respiratory gating using the RTRT showed the mean ± S.D. of 95{sup th} percentile E{sub EPID} were 1.3 ± 0.3 mm,1.1 ± 0.5 mm,and those of E{sub log} were 1.5 ± 0.2 mm, 1.1 ± 0.2 mm in LR and SI directions, respectively. Conclusion: We have developed the verification method of respiratory gating combined TrueBeam and new real-time tumor-tracking radiotherapy system using EPIDs and log files.« less

  1. Investigation of the effect of reducing scan resolution on simulated information-augmented sawing

    Treesearch

    Suraphan Thawornwong; Luis G. Occena; Daniel L. Schmoldt

    2000-01-01

    In the past few years, computed tomography (CT) scanning technology has been applied to the detection of internal defects in hardwood logs for the purpose of obtaining a priori information that can be used to arrive at better log breakdown or sawing decisions. Since today sawyers cannot even see the inside of the log until the log faces are revealed...

  2. Ultrafast CT scanning of an oak log for internal defects

    Treesearch

    Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder

    1989-01-01

    Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...

  3. Occurrence and removal of microbial indicators from municipal wastewaters by nine different MBR systems.

    PubMed

    Hirani, Zakir M; Decarolis, James F; Lehman, Geno; Adham, Samer S; Jacangelo, Joseph G

    2012-01-01

    Nine different membrane bioreactor (MBR) systems with different process configurations (submerged and external), membrane geometries (hollow-fiber, flat-sheet, and tubular), membrane materials (polyethersulfone (PES), polyvinylidene fluoride (PVDF), and polytetrafluoroethylene (PTFE)) and membrane nominal pore sizes (0.03-0.2 μm) were evaluated to assess the impact of influent microbial concentration, membrane pore size and membrane material and geometries on removal of microbial indicators by MBR technology. The log removal values (LRVs) for microbial indicators increased as the influent concentrations increased. Among the wide range of MBR systems evaluated, the total and fecal coliform bacteria and indigenous MS-2 coliphage were detected in 32, 9 and 15% of the samples, respectively; the 50th percentile LRVs were measured at 6.6, 5.9 and 4.5 logs, respectively. The nominal pore sizes of the membranes, membrane materials and geometries did not show a strong correlation with the LRVs.

  4. Distributed Intrusion Detection for Computer Systems Using Communicating Agents

    DTIC Science & Technology

    2000-01-01

    Log for a variety of suspicious events (like repeated failed login attempts), and alerts the IDAgent processes immediately via pipes when it finds...UX, IBM LAN Server, Raptor Eagle Firewalls, ANS Interlock Firewalls, and SunOS BSM. This program appears to be robust across many platforms. EMERALD ...Neumann, 1999] is a system developed by SRI International with research funding from DARPA. The EMERALD project will be the successor to Next

  5. Impact of Fiber Optics on System Reliability and Maintainability

    DTIC Science & Technology

    1988-06-01

    200 3-23 Log-normal plot showing the general relationship between emitter lifetime and case temperature . . .. 217 Chapter 4. PHOTODECTORS AND...stereo equipment use infrared signals to transmit the control information. Infrared light is also used in security systems for motion and intrusion...detection. Most modern grocery stores have laser scanners at the checkout line to read the bar code information printed on the packages. Infrared radar

  6. Detecting well casing leaks in Bangladesh using a salt spiking method

    USGS Publications Warehouse

    Stahl, M.O.; Ong, J.B.; Harvey, C.F.; Johnson, C.D.; Badruzzaman, A.B.M.; Tarek, M.H.; VanGeen, A.; Anderson, J.A.; Lane, J.W.

    2014-01-01

    We apply fluid-replacement logging in arsenic-contaminated regions of Bangladesh using a low-cost, down-well fluid conductivity logging tool to detect leaks in the cased section of wells. The fluid-conductivity tool is designed for the developing world: it is lightweight and easily transportable, operable by one person, and can be built for minimal cost. The fluid-replacement test identifies leaking casing by comparison of fluid conductivity logs collected before and after spiking the wellbore with a sodium chloride tracer. Here, we present results of fluid-replacement logging tests from both leaking and non-leaking casing from wells in Araihazar and Munshiganj, Bangladesh, and demonstrate that the low-cost tool produces measurements comparable to those obtained with a standard geophysical logging tool. Finally, we suggest well testing procedures and approaches for preventing casing leaks in Bangladesh and other developing countries.

  7. Detecting well casing leaks in Bangladesh using a salt spiking method.

    PubMed

    Stahl, M O; Ong, J B; Harvey, C F; Johnson, C D; Badruzzaman, A B M; Tarek, M H; van Geen, A; Anderson, J A; Lane, J W

    2014-09-01

    We apply fluid-replacement logging in arsenic-contaminated regions of Bangladesh using a low-cost, down-well fluid conductivity logging tool to detect leaks in the cased section of wells. The fluid-conductivity tool is designed for the developing world: it is lightweight and easily transportable, operable by one person, and can be built for minimal cost. The fluid-replacement test identifies leaking casing by comparison of fluid conductivity logs collected before and after spiking the wellbore with a sodium chloride tracer. Here, we present results of fluid-replacement logging tests from both leaking and non-leaking casing from wells in Araihazar and Munshiganj, Bangladesh, and demonstrate that the low-cost tool produces measurements comparable to those obtained with a standard geophysical logging tool. Finally, we suggest well testing procedures and approaches for preventing casing leaks in Bangladesh and other developing countries. © 2014, National Ground Water Association.

  8. Microbiological profile and incidence of Salmonella and Listeria monocytogenes on hydroponic bell peppers and greenhouse cultivation environment.

    PubMed

    Avila-Vega, Dulce E; Alvarez-Mayorga, Beatriz; Arvizu-Medrano, Sofía M; Pacheco-Aguilar, Ramiro; Martínez-Peniche, Ramón; Hernández-Iturriaga, Montserrat

    2014-11-01

    The aim of this study was to generate information regarding the microbiological profile, including Salmonella and Listeria monocytogenes incidence, of hydroponically grown bell peppers and materials associated with their production in greenhouses located in Mexico. Samples of coconut fiber (24), knives (30), drippers (20), conveyor belts (161), pepper transportation wagons (30), air (178), water (16), nutrient solution for plant irrigation (78), and bell pepper fruits (528) were collected during one cycle of production (2009 to 2010) for the quantification of microbial indicators (aerobic plate counts [APC], molds, coliforms, and Escherichia coli) and the detection of Salmonella and L. monocytogenes. With regard to surfaces (conveyor belts and wagons) and utensils (knives and drippers), the APC, coliform, and mold counts ranged from 3.0 to 6.0, from 1.4 to 6.3, and from 3.6 to 5.2 log CFU/100 cm(2) or per utensil, respectively. The air in the greenhouse contained low median levels of APC (1.2 to 1.4 log CFU/100 liters) and molds (2.2 to 2.5 log CFU/100 liters). The median content of APC and coliforms in water were 0.5 log CFU/ml and 0.3 log MPN/100 ml, respectively. The median content of coliforms in nutrient solution ranged from 1.8 to 2.4 log MPN/100 ml, and E. coli was detected in 18 samples (range, <0.3 to 1.2 log MPN/100 ml). On bell pepper analyzed during the study, populations (median) of APC, coliforms, and molds were 5.4, 3.6, and 5.8 log CFU per fruit, respectively; E. coli was detected in 5.1% of the samples (range, 0.23 to 1.4 log MPN per fruit). Salmonella was isolated from only one sample (1.6%) of conveyor belt located at the packing area and in four bell pepper samples (3%). L. monocytogenes was not detected. This information could help producers to establish effective control measures to prevent the presence of foodborne pathogens in bell peppers based on a scientific approach.

  9. Web-of-Objects (WoO)-Based Context Aware Emergency Fire Management Systems for the Internet of Things

    PubMed Central

    Shamszaman, Zia Ush; Ara, Safina Showkat; Chong, Ilyoung; Jeong, Youn Kwae

    2014-01-01

    Recent advancements in the Internet of Things (IoT) and the Web of Things (WoT) accompany a smart life where real world objects, including sensing devices, are interconnected with each other. The Web representation of smart objects empowers innovative applications and services for various domains. To accelerate this approach, Web of Objects (WoO) focuses on the implementation aspects of bringing the assorted real world objects to the Web applications. In this paper; we propose an emergency fire management system in the WoO infrastructure. Consequently, we integrate the formation and management of Virtual Objects (ViO) which are derived from real world physical objects and are virtually connected with each other into the semantic ontology model. The charm of using the semantic ontology is that it allows information reusability, extensibility and interoperability, which enable ViOs to uphold orchestration, federation, collaboration and harmonization. Our system is context aware, as it receives contextual environmental information from distributed sensors and detects emergency situations. To handle a fire emergency, we present a decision support tool for the emergency fire management team. The previous fire incident log is the basis of the decision support system. A log repository collects all the emergency fire incident logs from ViOs and stores them in a repository. PMID:24531299

  10. Web-of-Objects (WoO)-based context aware emergency fire management systems for the Internet of Things.

    PubMed

    Shamszaman, Zia Ush; Ara, Safina Showkat; Chong, Ilyoung; Jeong, Youn Kwae

    2014-02-13

    Recent advancements in the Internet of Things (IoT) and the Web of Things (WoT) accompany a smart life where real world objects, including sensing devices, are interconnected with each other. The Web representation of smart objects empowers innovative applications and services for various domains. To accelerate this approach, Web of Objects (WoO) focuses on the implementation aspects of bringing the assorted real world objects to the Web applications. In this paper; we propose an emergency fire management system in the WoO infrastructure. Consequently, we integrate the formation and management of Virtual Objects (ViO) which are derived from real world physical objects and are virtually connected with each other into the semantic ontology model. The charm of using the semantic ontology is that it allows information reusability, extensibility and interoperability, which enable ViOs to uphold orchestration, federation, collaboration and harmonization. Our system is context aware, as it receives contextual environmental information from distributed sensors and detects emergency situations. To handle a fire emergency, we present a decision support tool for the emergency fire management team. The previous fire incident log is the basis of the decision support system. A log repository collects all the emergency fire incident logs from ViOs and stores them in a repository.

  11. SU-E-T-144: Effective Analysis of VMAT QA Generated Trajectory Log Files for Medical Accelerator Predictive Maintenance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Able, CM; Baydush, AH; Nguyen, C

    Purpose: To determine the effectiveness of SPC analysis for a model predictive maintenance process that uses accelerator generated parameter and performance data contained in trajectory log files. Methods: Each trajectory file is decoded and a total of 131 axes positions are recorded (collimator jaw position, gantry angle, each MLC, etc.). This raw data is processed and either axis positions are extracted at critical points during the delivery or positional change over time is used to determine axis velocity. The focus of our analysis is the accuracy, reproducibility and fidelity of each axis. A reference positional trace of the gantry andmore » each MLC is used as a motion baseline for cross correlation (CC) analysis. A total of 494 parameters (482 MLC related) were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and parameter/system specifications. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: TG-142 and published analysis of VMAT delivery accuracy. Results: All errors introduced were detected. Synthetic positional errors of 2mm for collimator jaw and MLC carriage exceeded the chart limits. Gantry speed and each MLC speed are analyzed at two different points in the delivery. Simulated Gantry speed error (0.2 deg/sec) and MLC speed error (0.1 cm/sec) exceeded the speed chart limits. Gantry position error of 0.2 deg was detected by the CC maximum value charts. The MLC position error of 0.1 cm was detected by the CC maximum value location charts for every MLC. Conclusion: SPC I/MR evaluation of trajectory log file parameters may be effective in providing an early warning of performance degradation or component failure for medical accelerator systems.« less

  12. Improved grading system for structural logs for log homes

    Treesearch

    D.W. Green; T.M. Gorman; J.W. Evans; J.F. Murphy

    2004-01-01

    Current grading standards for logs used in log home construction use visual criteria to sort logs into either “wall logs” or structural logs (round and sawn round timbers). The conservative nature of this grading system, and the grouping of stronger and weaker species for marketing purposes, probably results in the specification of logs with larger diameter than would...

  13. Analytical characteristics and comparative evaluation of Aptima HIV-1 Quant Dx assay with Ampliprep/COBAS TaqMan HIV-1 test v2.0.

    PubMed

    Hatzakis, Angelos; Papachristou, Helen; Nair, Sangeetha J; Fortunko, Jacqueline; Foote, Tracy; Kim, HeeCheol; Peling, Tashi L; Worlock, Andrew J

    2016-10-21

    Quantitation of HIV-RNA is critically important for diagnosis, prognosis, treatment, monitoring and assessment of infectivity in HIV-1 infection. The objective of this study was to assess performance characteristics of the Aptima HIV-1 Quant Dx assay (Aptima), a new transcription mediated amplification (TMA), fully integrated and automated assay from Hologic Inc., San Diego, CA, USA. The analytical sensitivity, analytical specificity, precision and detection of HIV-1 subtypes were tested based on commercially available international standards or panels. A selected group of 244 anti-HIV-1 (+) plasma samples was used for comparison with Roche COBAS Ampliprep/COBAS TaqMan HIV- 1 test v2.0 (Roche CAP/CTM), (Roche Molecular Systems, Pleasanton, CA). The 50 and 95 % limit of detection were estimated at 4.9 (95 % CI 3.9-5.7) and 17.6 (15.2-21.2) IU/mL respectively. The specificity was found 99.83 (99.06-99.97) %. The standard deviations and coefficient of variations for panels with 50 and 100 copies/mL (1.7 and 2 log copies/mL) were 0.14 log copies/mL (8.67 %CV) and 0.18 log copies/mL (9.91 %CV) respectively. The detection rate for Aptima and Roche assays was 220/244 (90.2 %) and 217/244 (88.9 %) respectively. The Aptima assay is a sensitive, specific, precise and accurate test for measuring HIV-1 viral loads and for the detection of HIV-1 infections.

  14. Novel Desorber for Online Drilling Mud Gas Logging

    PubMed Central

    Lackowski, Marcin; Tobiszewski, Marek; Namieśnik, Jacek

    2016-01-01

    This work presents the construction solution and experimental results of a novel desorber for online drilling mud gas logging. The traditional desorbers use mechanical mixing of the liquid to stimulate transfer of hydrocarbons to the gaseous phase that is further analyzed. The presented approach is based on transfer of hydrocarbons from the liquid to the gas bubbles flowing through it and further gas analysis. The desorber was checked for gas logging from four different drilling muds collected from Polish boreholes. The results of optimization studies are also presented in this study. The comparison of the novel desorber with a commercial one reveals strong advantages of the novel one. It is characterized by much better hydrocarbons recovery efficiency and allows reaching lower limits of detection of the whole analytical system. The presented desorber seems to be very attractive alternative over widely used mechanical desorbers. PMID:27127674

  15. Performance evaluation of the QIAGEN EZ1 DSP Virus Kit with Abbott RealTime HIV-1, HBV and HCV assays.

    PubMed

    Schneider, George J; Kuper, Kevin G; Abravaya, Klara; Mullen, Carolyn R; Schmidt, Marion; Bunse-Grassmann, Astrid; Sprenger-Haussels, Markus

    2009-04-01

    Automated sample preparation systems must meet the demands of routine diagnostics laboratories with regard to performance characteristics and compatibility with downstream assays. In this study, the performance of QIAGEN EZ1 DSP Virus Kit on the BioRobot EZ1 DSP was evaluated in combination with the Abbott RealTime HIV-1, HCV, and HBV assays, followed by thermalcycling and detection on the Abbott m2000rt platform. The following performance characteristics were evaluated: linear range and precision, sensitivity, cross-contamination, effects of interfering substances and correlation. Linearity was observed within the tested ranges (for HIV-1: 2.0-6.0 log copies/ml, HCV: 1.3-6.9 log IU/ml, HBV: 1.6-7.6 log copies/ml). Excellent precision was obtained (inter-assay standard deviation for HIV-1: 0.06-0.17 log copies/ml (>2.17 log copies/ml), HCV: 0.05-0.11 log IU/ml (>2.09 log IU/ml), HBV: 0.03-0.07 log copies/ml (>2.55 log copies/ml)), with good sensitivity (95% hit rates for HIV-1: 50 copies/ml, HCV: 12.5 IU/ml, HBV: 10 IU/ml). No cross-contamination was observed, as well as no negative impact of elevated levels of various interfering substances. In addition, HCV and HBV viral load measurements after BioRobot EZ1 DSP extraction correlated well with those obtained after Abbott m2000sp extraction. This evaluation demonstrates that the QIAGEN EZ1 DSP Virus Kit provides an attractive solution for fully automated, low throughput sample preparation for use with the Abbott RealTime HIV-1, HCV, and HBV assays.

  16. Physical conditions in the neutral interstellar medium at z = 2.43 toward Q 2348-011

    NASA Astrophysics Data System (ADS)

    Noterdaeme, P.; Petitjean, P.; Srianand, R.; Ledoux, C.; Le Petit, F.

    2007-07-01

    Aims:We aim at deriving the physical conditions in the neutral gas associated with damped Lyman-α systems using observation and analysis of H2 and C i absorptions. Methods: We obtained a high-resolution VLT-UVES spectrum of the quasar Q 2348-011 over a wavelength range that covers most of the prominent metal and molecular absorption lines from the log N(H i) = 20.50 ± 0.10 damped Lyman-α system at z_abs=2.4263. We detected H2 in this system and measured column densities of H2, C i, C i^*, C i**, Si ii, P ii, S ii, Fe ii, and Ni ii. From the column density ratios and, in particular, the relative populations of H2 rotational and C i fine-structure levels, we derived the physical conditions in the gas (relative abundances, dust-depletion, particle density, kinetic temperature, and ionising flux) and discuss physical conditions in the neutral phase. Results: Molecular hydrogen was detected in seven components in the first four rotational levels (J = 0-3) of the vibrational ground state. Absorption lines of H2 J=4 (resp. J = 5) rotational levels are detected in six (resp. two) of these components. This leads to a total molecular fraction of log f ≃ -1.69+0.37-0.58. Fourteen components are needed to reproduce the metal-line profiles. The overall metallicity is found to be -0.80, -0.62, -1.17 ± 0.10 for, respectively, [Si/H], [S/H] and [Fe/H]. We confirm the earlier findings that there is a correlation between log N(Fe ii)/N(S ii) and log N(Si ii)/N(S ii) from different components indicative of a dust-depletion pattern. Surprisingly, however, the depletion of metals onto dust in the H2 components is not large in this system: [Fe/S] = -0.8 to -0.1. The gas in H2-bearing components is found to be cold but still hotter than similar gas in our Galaxy (T > 130 K, instead of typically 80 K) and dense (n ˜ 100-200 cm-3). There is an anti-correlation (R=-0.97) between the logarithm of the photo-absorption rate, log β_0, and log N(H2)/N(C i) derived for each H2 component. We show that this is mostly due to shielding effects and imply that the photo-absorption rate β0 is a good indicator of the physical conditions in the gas. We find that the gas is immersed in an intense UV field, about one order of magnitude higher than in the solar vicinity. These results suggest that the gas in H2-bearing DLAs is clumpy, and star-formation occurs in the associated object. Based on observations carried out at the European Southern Observatory (ESO) under prog. ID No. 072.A-0346 with the UVES spectrograph installed at the Very Large Telescope (VLT) Unit 2, Kueyen, on Cerro Paranal, Chile.

  17. Comparison of different approaches to quantitative adenovirus detection in stool specimens of hematopoietic stem cell transplant recipients.

    PubMed

    Kosulin, K; Dworzak, S; Lawitschka, A; Matthes-Leodolter, S; Lion, T

    2016-12-01

    Adenoviruses almost invariably proliferate in the gastrointestinal tract prior to dissemination, and critical threshold concentrations in stool correlate with the risk of viremia. Monitoring of adenovirus loads in stool may therefore be important for timely initiation of treatment in order to prevent invasive infection. Comparison of a manual DNA extraction kit in combination with a validated in-house PCR assay with automated extraction on the NucliSENS-EasyMAG device coupled with the Adenovirus R-gene kit (bioMérieux) for quantitative adenovirus analysis in stool samples. Stool specimens spiked with adenovirus concentrations in a range from 10E2-10E11 copies/g and 32 adenovirus-positive clinical stool specimens from pediatric stem cell transplant recipients were tested along with appropriate negative controls. Quantitative analysis of viral load in adenovirus-positive stool specimens revealed a median difference of 0.5 logs (range 0.1-2.2) between the detection systems tested and a difference of 0.3 logs (range 0.0-1.7) when the comparison was restricted to the PCR assays only. Spiking experiments showed a detection limit of 10 2 -10 3 adenovirus copies/g stool revealing a somewhat higher sensitivity offered by the automated extraction. The dynamic range of accurate quantitative analysis by both systems investigated was between 10 3 and 10 8 virus copies/g. The differences in quantitative analysis of adenovirus copy numbers between the systems tested were primarily attributable to the DNA extraction method used, while the qPCR assays revealed a high level of concordance. Both systems showed adequate performance for detection and monitoring of adenoviral load in stool specimens. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Inactivation of Ebola virus and Middle East respiratory syndrome coronavirus in platelet concentrates and plasma by ultraviolet C light and methylene blue plus visible light, respectively.

    PubMed

    Eickmann, Markus; Gravemann, Ute; Handke, Wiebke; Tolksdorf, Frank; Reichenberg, Stefan; Müller, Thomas H; Seltsam, Axel

    2018-05-06

    Ebola virus (EBOV) and Middle East respiratory syndrome coronavirus (MERS-CoV) have been identified as potential threats to blood safety. This study investigated the efficacy of the THERAFLEX UV-Platelets and THERAFLEX MB-Plasma pathogen inactivation systems to inactivate EBOV and MERS-CoV in platelet concentrates (PCs) and plasma, respectively. PCs and plasma were spiked with high titers of cell culture-derived EBOV and MERS-CoV, treated with various light doses of ultraviolet C (UVC; THERAFLEX UV-Platelets) or methylene blue (MB) plus visible light (MB/light; THERAFLEX MB-Plasma), and assessed for residual viral infectivity. UVC reduced EBOV (≥4.5 log) and MERS-CoV (≥3.7 log) infectivity in PCs to the limit of detection, and MB/light decreased EBOV (≥4.6 log) and MERS-CoV (≥3.3 log) titers in plasma to nondetectable levels. Both THERAFLEX UV-Platelets (UVC) and THERAFLEX MB-Plasma (MB/light) effectively reduce EBOV and MERS-CoV infectivity in platelets and plasma, respectively. © 2018 AABB.

  19. Development of an Advanced Aidman Vision Screener (AVS) for selective assessment of outer and inner laser induced retinal injury

    NASA Astrophysics Data System (ADS)

    Boye, Michael W.; Zwick, Harry; Stuck, Bruce E.; Edsall, Peter R.; Akers, Andre

    2007-02-01

    The need for tools that can assist in evaluating visual function is an essential and a growing requirement as lasers on the modern battlefield mature and proliferate. The requirement for rapid and sensitive vision assessment under field conditions produced the USAMRD Aidman Vision Screener (AVS), designed to be used as a field diagnostic tool for assessing laser induced retinal damage. In this paper, we describe additions to the AVS designed to provide a more sensitive assessment of laser induced retinal dysfunction. The AVS incorporates spectral LogMar Acuity targets without and with neural opponent chromatic backgrounds. Thus, it provides the capability of detecting selective photoreceptor damage and its functional consequences at the level of both the outer and inner retina. Modifications to the original achromatic AVS have been implemented to detect selective cone system dysfunction by providing LogMar acuity Landolt rings associated with the peak spectral absorption regions of the S (short), M (middle), and L (long) wavelength cone photoreceptor systems. Evaluation of inner retinal dysfunction associated with selective outer cone damage employs LogMar spectral acuity charts with backgrounds that are neurally opponent. Thus, the AVS provides the capability to assess the effect of selective cone dysfunction on the normal neural balance at the level of the inner retinal interactions. Test and opponent background spectra have been optimized by using color space metrics. A minimal number of three AVS evaluations will be utilized to provide an estimate of false alarm level.

  20. Survival and Transfer of Murine Norovirus within a Hydroponic System during Kale and Mustard Microgreen Harvesting.

    PubMed

    Wang, Qing; Kniel, Kalmia E

    2016-01-15

    Hydroponically grown microgreens are gaining in popularity, but there is a lack of information pertaining to their microbiological safety. The potential risks associated with virus contamination of crops within a hydroponic system have not been studied to date. Here a human norovirus (huNoV) surrogate (murine norovirus [MNV]) was evaluated for its ability to become internalized from roots to edible tissues of microgreens. Subsequently, virus survival in recirculated water without adequate disinfection was assessed. Kale and mustard seeds were grown on hydroponic pads (for 7 days with harvest at days 8 to 12), edible tissues (10 g) were cut 1 cm above the pads, and corresponding pieces (4 cm by 4 cm) of pads containing only roots were collected separately. Samples were collected from a newly contaminated system (recirculated water inoculated with ∼3 log PFU/ml MNV on day 8) and from a previously contaminated system. (A contaminated system without adequate disinfection or further inoculation was used for production of another set of microgreens.) Viral titers and RNA copies were quantified by plaque assay and real-time reverse transcription (RT)-PCR. The behaviors of MNV in kale and mustard microgreens were similar (P > 0.05). MNV was detected in edible tissues and roots after 2 h postinoculation, and the levels were generally stable during the first 12 h. Relatively low levels (∼2.5 to ∼1.5 log PFU/sample of both edible tissues and roots) of infectious viruses were found with a decreasing trend over time from harvest days 8 to 12. However, the levels of viral RNA present were higher and consistently stable (∼4.0 to ∼5.5 log copies/sample). Recirculated water maintained relatively high levels of infectious MNV over the period of harvest, from 3.54 to 2.73 log PFU/ml. Importantly, cross-contamination occurred easily; MNV remained infectious in previously contaminated hydroponic systems for up to 12 days (2.26 to 1.00 PFU/ml), and MNV was detected in both edible tissues and roots. Here we see that viruses can be recirculated in water, even after an initial contamination event is removed, taken up through the roots of microgreens, and transferred to edible tissues. The ease of product contamination shown here reinforces the need for proper sanitation. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  1. Survival and Transfer of Murine Norovirus within a Hydroponic System during Kale and Mustard Microgreen Harvesting

    PubMed Central

    Wang, Qing

    2015-01-01

    Hydroponically grown microgreens are gaining in popularity, but there is a lack of information pertaining to their microbiological safety. The potential risks associated with virus contamination of crops within a hydroponic system have not been studied to date. Here a human norovirus (huNoV) surrogate (murine norovirus [MNV]) was evaluated for its ability to become internalized from roots to edible tissues of microgreens. Subsequently, virus survival in recirculated water without adequate disinfection was assessed. Kale and mustard seeds were grown on hydroponic pads (for 7 days with harvest at days 8 to 12), edible tissues (10 g) were cut 1 cm above the pads, and corresponding pieces (4 cm by 4 cm) of pads containing only roots were collected separately. Samples were collected from a newly contaminated system (recirculated water inoculated with ∼3 log PFU/ml MNV on day 8) and from a previously contaminated system. (A contaminated system without adequate disinfection or further inoculation was used for production of another set of microgreens.) Viral titers and RNA copies were quantified by plaque assay and real-time reverse transcription (RT)-PCR. The behaviors of MNV in kale and mustard microgreens were similar (P > 0.05). MNV was detected in edible tissues and roots after 2 h postinoculation, and the levels were generally stable during the first 12 h. Relatively low levels (∼2.5 to ∼1.5 log PFU/sample of both edible tissues and roots) of infectious viruses were found with a decreasing trend over time from harvest days 8 to 12. However, the levels of viral RNA present were higher and consistently stable (∼4.0 to ∼5.5 log copies/sample). Recirculated water maintained relatively high levels of infectious MNV over the period of harvest, from 3.54 to 2.73 log PFU/ml. Importantly, cross-contamination occurred easily; MNV remained infectious in previously contaminated hydroponic systems for up to 12 days (2.26 to 1.00 PFU/ml), and MNV was detected in both edible tissues and roots. Here we see that viruses can be recirculated in water, even after an initial contamination event is removed, taken up through the roots of microgreens, and transferred to edible tissues. The ease of product contamination shown here reinforces the need for proper sanitation. PMID:26567309

  2. Camera trap placement and the potential for bias due to trails and other features

    PubMed Central

    Forrester, Tavis D.

    2017-01-01

    Camera trapping has become an increasingly widespread tool for wildlife ecologists, with large numbers of studies relying on photo capture rates or presence/absence information. It is increasingly clear that camera placement can directly impact this kind of data, yet these biases are poorly understood. We used a paired camera design to investigate the effect of small-scale habitat features on species richness estimates, and capture rate and detection probability of several mammal species in the Shenandoah Valley of Virginia, USA. Cameras were deployed at either log features or on game trails with a paired camera at a nearby random location. Overall capture rates were significantly higher at trail and log cameras compared to their paired random cameras, and some species showed capture rates as much as 9.7 times greater at feature-based cameras. We recorded more species at both log (17) and trail features (15) than at their paired control cameras (13 and 12 species, respectively), yet richness estimates were indistinguishable after 659 and 385 camera nights of survey effort, respectively. We detected significant increases (ranging from 11–33%) in detection probability for five species resulting from the presence of game trails. For six species detection probability was also influenced by the presence of a log feature. This bias was most pronounced for the three rodents investigated, where in all cases detection probability was substantially higher (24.9–38.2%) at log cameras. Our results indicate that small-scale factors, including the presence of game trails and other features, can have significant impacts on species detection when camera traps are employed. Significant biases may result if the presence and quality of these features are not documented and either incorporated into analytical procedures, or controlled for in study design. PMID:29045478

  3. Camera trap placement and the potential for bias due to trails and other features.

    PubMed

    Kolowski, Joseph M; Forrester, Tavis D

    2017-01-01

    Camera trapping has become an increasingly widespread tool for wildlife ecologists, with large numbers of studies relying on photo capture rates or presence/absence information. It is increasingly clear that camera placement can directly impact this kind of data, yet these biases are poorly understood. We used a paired camera design to investigate the effect of small-scale habitat features on species richness estimates, and capture rate and detection probability of several mammal species in the Shenandoah Valley of Virginia, USA. Cameras were deployed at either log features or on game trails with a paired camera at a nearby random location. Overall capture rates were significantly higher at trail and log cameras compared to their paired random cameras, and some species showed capture rates as much as 9.7 times greater at feature-based cameras. We recorded more species at both log (17) and trail features (15) than at their paired control cameras (13 and 12 species, respectively), yet richness estimates were indistinguishable after 659 and 385 camera nights of survey effort, respectively. We detected significant increases (ranging from 11-33%) in detection probability for five species resulting from the presence of game trails. For six species detection probability was also influenced by the presence of a log feature. This bias was most pronounced for the three rodents investigated, where in all cases detection probability was substantially higher (24.9-38.2%) at log cameras. Our results indicate that small-scale factors, including the presence of game trails and other features, can have significant impacts on species detection when camera traps are employed. Significant biases may result if the presence and quality of these features are not documented and either incorporated into analytical procedures, or controlled for in study design.

  4. Estimates of Social Contact in a Middle School Based on Self-Report and Wireless Sensor Data.

    PubMed

    Leecaster, Molly; Toth, Damon J A; Pettey, Warren B P; Rainey, Jeanette J; Gao, Hongjiang; Uzicanin, Amra; Samore, Matthew

    2016-01-01

    Estimates of contact among children, used for infectious disease transmission models and understanding social patterns, historically rely on self-report logs. Recently, wireless sensor technology has enabled objective measurement of proximal contact and comparison of data from the two methods. These are mostly small-scale studies, and knowledge gaps remain in understanding contact and mixing patterns and also in the advantages and disadvantages of data collection methods. We collected contact data from a middle school, with 7th and 8th grades, for one day using self-report contact logs and wireless sensors. The data were linked for students with unique initials, gender, and grade within the school. This paper presents the results of a comparison of two approaches to characterize school contact networks, wireless proximity sensors and self-report logs. Accounting for incomplete capture and lack of participation, we estimate that "sensor-detectable", proximal contacts longer than 20 seconds during lunch and class-time occurred at 2 fold higher frequency than "self-reportable" talk/touch contacts. Overall, 55% of estimated talk-touch contacts were also sensor-detectable whereas only 15% of estimated sensor-detectable contacts were also talk-touch. Contacts detected by sensors and also in self-report logs had longer mean duration than contacts detected only by sensors (6.3 vs 2.4 minutes). During both lunch and class-time, sensor-detectable contacts demonstrated substantially less gender and grade assortativity than talk-touch contacts. Hallway contacts, which were ascertainable only by proximity sensors, were characterized by extremely high degree and short duration. We conclude that the use of wireless sensors and self-report logs provide complementary insight on in-school mixing patterns and contact frequency.

  5. One Way of Testing a Distributed Processor

    NASA Technical Reports Server (NTRS)

    Edstrom, R.; Kleckner, D.

    1982-01-01

    Launch processing for Space Shuttle is checked out, controlled, and monitored with new system. Entire system can be exercised by two computer programs--one in master console and other in each of operations consoles. Control program in each operations console detects change in status and begins task initiation. All of front-end processors are exercised from consoles through common data buffer, and all data are logged to processed-data recorder for posttest analysis.

  6. Study of Adversarial and Defensive Components in an Experimental Machinery Control Systems Laboratory Environment

    DTIC Science & Technology

    2014-09-01

    prevention system (IPS), capable of performing real-time traffic analysis and packet logging on IP networks [25]. Snort’s features include protocol... analysis and content searching/matching. Snort can detect a variety of attacks and network probes, such as buffer overflows, port scans and OS...www.digitalbond.com/tools/the- rack/jtr-s7-password-cracking/ Kismet Mike Kershaw Cross- platform Open source wireless network detector and wireless sniffer

  7. Evaluation of permeable fractures in rock aquifers

    NASA Astrophysics Data System (ADS)

    Bok Lee, Hang

    2015-04-01

    In this study, the practical usefulness and fundamental applicability of a self-potential (SP) method for identifying the permeable fractures were evaluated by a comparison of SP methods with other geophysical logging methods and hydraulic tests. At a 10 m-shallow borehole in the study site, the candidates of permeable fractures crossing the borehole were first determined by conventional geophysical methods such as an acoustic borehole televiwer, temperature, electrical conductivity and gamma-gamma loggings, which was compared to the analysis by the SP method. Constant pressure injection and recovery tests were conducted for verification of the hydraulic properties of the fractures identified by various logging methods. The acoustic borehole televiwer and gamma-gamma loggings detected the open space or weathering zone within the borehole, but they cannot prove the possibility of a groundwater flow through the detected fractures. The temperature and electrical conductivity loggings had limitations to detect the fractured zones where groundwater in the borehole flows out to the surrounding rock aquifers. Comparison of results from different methods showed that there is a best correlation between the distribution of hydraulic conductivity and the variation of the SP signals, and the SP logging can estimate accurately the hydraulic activity as well as the location of permeable fractures. Based on the results, the SP method is recommended for determining the hydraulically-active fractures rather than other conventional geophysical loggings. This self-potential method can be effectively applied in the initial stage of a site investigation which selects the optimal location and evaluates the hydrogeological property of fractures in target sites for the underground structure including the geothermal reservoir and radioactive waste disposal.

  8. Progress in analysis of computed tomography (CT) images of hardwood logs for defect detection

    Treesearch

    Erol Sarigul; A. Lynn Abbott; Daniel L. Schmoldt

    2003-01-01

    This paper addresses the problem of automatically detecting internal defects in logs using computed tomography (CT) images. The overall purpose is to assist in breakdown optimization. Several studies have shown that the commercial value of resulting boards can be increased substantially if defect locations are known in advance, and if this information is used to make...

  9. Actual distribution of Cronobacter spp. in industrial batches of powdered infant formula and consequences for performance of sampling strategies.

    PubMed

    Jongenburger, I; Reij, M W; Boer, E P J; Gorris, L G M; Zwietering, M H

    2011-11-15

    The actual spatial distribution of microorganisms within a batch of food influences the results of sampling for microbiological testing when this distribution is non-homogeneous. In the case of pathogens being non-homogeneously distributed, it markedly influences public health risk. This study investigated the spatial distribution of Cronobacter spp. in powdered infant formula (PIF) on industrial batch-scale for both a recalled batch as well a reference batch. Additionally, local spatial occurrence of clusters of Cronobacter cells was assessed, as well as the performance of typical sampling strategies to determine the presence of the microorganisms. The concentration of Cronobacter spp. was assessed in the course of the filling time of each batch, by taking samples of 333 g using the most probable number (MPN) enrichment technique. The occurrence of clusters of Cronobacter spp. cells was investigated by plate counting. From the recalled batch, 415 MPN samples were drawn. The expected heterogeneous distribution of Cronobacter spp. could be quantified from these samples, which showed no detectable level (detection limit of -2.52 log CFU/g) in 58% of samples, whilst in the remainder concentrations were found to be between -2.52 and 2.75 log CFU/g. The estimated average concentration in the recalled batch was -2.78 log CFU/g and a standard deviation of 1.10 log CFU/g. The estimated average concentration in the reference batch was -4.41 log CFU/g, with 99% of the 93 samples being below the detection limit. In the recalled batch, clusters of cells occurred sporadically in 8 out of 2290 samples of 1g taken. The two largest clusters contained 123 (2.09 log CFU/g) and 560 (2.75 log CFU/g) cells. Various sampling strategies were evaluated for the recalled batch. Taking more and smaller samples and keeping the total sampling weight constant, considerably improved the performance of the sampling plans to detect such a type of contaminated batch. Compared to random sampling, stratified random sampling improved the probability to detect the heterogeneous contamination. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. WikiLeaks and Iraq Body Count: the sum of parts may not add up to the whole-a comparison of two tallies of Iraqi civilian deaths.

    PubMed

    Carpenter, Dustin; Fuller, Tova; Roberts, Les

    2013-06-01

    Introduction The number of civilians killed in Iraq following the 2003 invasion has proven difficult to measure and contentious in recent years. The release of the Wikileaks War Logs (WL) has created the potential to conduct a sensitivity analysis of the commonly-cited Iraq Body Count's (IBC's) tally, which is based on press, government, and other public sources. Hypothesis The 66,000 deaths reported in the Wikileaks War Logs are mostly the same events as those previously reported in the press and elsewhere as tallied by iraqbodycount.org. A systematic random sample of 2500 violent fatal War Log incidents was selected and evaluated to determine whether these incidents were also found in IBC's press-based listing. Each selected event was ranked on a scale of 0 (no match present) to 3 (almost certainly matched) with regard to the likelihood it was listed in the IBC database. Of the two thousand four hundred and nine War Log records, 488 (23.8%) were found to have likely matches in IBC records. Events that killed more people were far more likely to appear in both datasets, with 94.1% of events in which ≥20 people were killed being likely matches, as compared with 17.4% of singleton killings. Because of this skew towards the recording of large events in both datasets, it is estimated that 2035 (46.3%) of the 4394 deaths reported in the Wikileaks War Logs had been previously reported in IBC. Passive surveillance systems, widely seen as incomplete, may also be selective in the types of events detected in times of armed conflict. Bombings and other events during which many people are killed, and events in less violent areas, appear to be detected far more often, creating a skewed image of the mortality profile in Iraq. Members of the press and researchers should be hesitant to draw conclusions about the nature or extent of violence from passive surveillance systems of low or unknown sensitivity.

  11. 1987 Nuclear Science Symposium, 34th, and 1987 Symposium on Nuclear Power Systems, 19th, San Francisco, CA, Oct. 21-23, 1987, Proceedings

    NASA Astrophysics Data System (ADS)

    Armantrout, Guy A.

    1988-02-01

    The present conference consideres topics in radiation detectors, advanced electronic circuits, data acquisition systems, radiation detector systems, high-energy and nuclear physics radiation detection, spaceborne instrumentation, health physics and environmental radiation detection, nuclear medicine, nuclear well logging, and nuclear reactor instrumentation. Attention is given to the response of scintillators to heavy ions, phonon-mediated particle detection, ballistic deficits in pulse-shaping amplifiers, fast analog ICs for particle physics, logic cell arrays, the CERN host interface, high performance data buses, a novel scintillating glass for high-energy physics applications, background events in microchannel plates, a tritium accelerator mass spectrometer, a novel positron tomograph, advancements in PET, cylindrical positron tomography, nuclear techniques in subsurface geology, REE borehole neutron activation, and a continuous tritium monitor for aqueous process streams.

  12. Including operational data in QMRA model: development and impact of model inputs.

    PubMed

    Jaidi, Kenza; Barbeau, Benoit; Carrière, Annie; Desjardins, Raymond; Prévost, Michèle

    2009-03-01

    A Monte Carlo model, based on the Quantitative Microbial Risk Analysis approach (QMRA), has been developed to assess the relative risks of infection associated with the presence of Cryptosporidium and Giardia in drinking water. The impact of various approaches for modelling the initial parameters of the model on the final risk assessments is evaluated. The Monte Carlo simulations that we performed showed that the occurrence of parasites in raw water was best described by a mixed distribution: log-Normal for concentrations > detection limit (DL), and a uniform distribution for concentrations < DL. The selection of process performance distributions for modelling the performance of treatment (filtration and ozonation) influences the estimated risks significantly. The mean annual risks for conventional treatment are: 1.97E-03 (removal credit adjusted by log parasite = log spores), 1.58E-05 (log parasite = 1.7 x log spores) or 9.33E-03 (regulatory credits based on the turbidity measurement in filtered water). Using full scale validated SCADA data, the simplified calculation of CT performed at the plant was shown to largely underestimate the risk relative to a more detailed CT calculation, which takes into consideration the downtime and system failure events identified at the plant (1.46E-03 vs. 3.93E-02 for the mean risk).

  13. Technoeconomic analysis of conventional logging systems operating from stump to landing

    Treesearch

    Raymond L. Sarles; William G. Luppold; William G. Luppold

    1986-01-01

    Analyzes technical and economic factors for six conventional logging systems suitable for operation in eastern forests. Discusses financial risks and business implications for loggers investing in high-production, state-of-the-art logging systems. Provides logging contractors with information useful as a preliminary guide for selection of equipment and systems....

  14. Effectiveness of onsite wastewater reuse system in reducing bacterial contaminants measured with human-specific IMS/ATP and qPCR.

    PubMed

    Agidi, Senyo; Vedachalam, Sridhar; Mancl, Karen; Lee, Jiyoung

    2013-01-30

    Water shortages and the drive to recycle is increasing interest in reuse of reclaimed wastewater. Timely and cost-effective ways to detect fecal pollutants prior to reuse increases confidence of residents and neighbors concerned about reuse of reclaimed wastewater. The on-site wastewater treatment and reuse systems (OWTRS) used in this study include a septic tank, peat bioreactor, ClO(2) disinfection and land spray irrigation system. Bacteroides fragilis, Escherichia coli and Enterococcus spp., were tested with immunomagnetic separation/ATP bioluminescence (IMS/ATP), qPCR and culture-based methods. The results displayed a 2-log reduction in fecal bacteria in the peat bioreactor and a 5-log reduction following chloride dioxide disinfection. The fecal bacteria levels measured by IMS/ATP correlated with qPCR results: HuBac 16S (R(2) = 0.903), Bf-group 16S (R(2) = 0.956), gyrB (R(2) = 0.673), and Ent 23S (R(2) = 0.724). This is the first study in which the newly developed human-specific IMS/ATP and previously developed IMS/ATP were applied for determining OWTRS efficiency. Results of the study revealed that IMS/ATP is a timely and cost-effective way to detect fecal contaminants, and results were validated with qPCR and culture based methods. The new IMS/ATP can also be applied broadly in the detection of human-originated fecal contamination. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Normalization of test and evaluation of biothreat detection systems: overcoming microbial air content fluctuations by using a standardized reagent bacterial mixture.

    PubMed

    Berchebru, Laurent; Rameil, Pascal; Gaudin, Jean-Christophe; Gausson, Sabrina; Larigauderie, Guilhem; Pujol, Céline; Morel, Yannick; Ramisse, Vincent

    2014-10-01

    Test and evaluation of engineered biothreat agent detection systems ("biodetectors") are a challenging task for government agencies and industries involved in biosecurity and biodefense programs. In addition to user friendly features, biodetectors need to perform both highly sensitive and specific detection, and must not produce excessive false alerts. In fact, the atmosphere displays a number of variables such as airborne bacterial content that can interfere with the detection process, thus impeding comparative tests when carried out at different times or places. To overcome these bacterial air content fluctuations, a standardized reagent bacterial mixture (SRBM), consisting in a collection of selected cultivable environmental species that are prevalent in temperate climate bioaerosols, was designed to generate a stable, reproducible, and easy to use surrogate of bioaerosol sample. The rationale, design, and production process are reported. The results showed that 8.59; CI 95%: 8.46-8.72 log cfu distributed into vials underwent a 0.95; CI 95%: 0.65-1.26 log viability decay after dehydration and subsequent reconstitution, thus advantageously mimicking a natural bioaerosol sample which is typically composed of cultivable and uncultivable particles. Dehydrated SRBM was stable for more than 12months at 4°C and allowed the reconstitution of a dead/live cells aqueous suspension that is stable for 96h at +4°C, according to plate counts. Specific detection of a simulating biothreat agent (e.g. Bacillus atrophaeus) by immuno-magnetic or PCR assays did not display any significant loss of sensitivity, false negative or positive results in the presence of SRBM. This work provides guidance on testing and evaluating detection devices, and may contribute to the establishment of suitable standards and normalized procedures. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Fracture identification based on remote detection acoustic reflection logging

    NASA Astrophysics Data System (ADS)

    Zhang, Gong; Li, Ning; Guo, Hong-Wei; Wu, Hong-Liang; Luo, Chao

    2015-12-01

    Fracture identification is important for the evaluation of carbonate reservoirs. However, conventional logging equipment has small depth of investigation and cannot detect rock fractures more than three meters away from the borehole. Remote acoustic logging uses phase-controlled array-transmitting and long sound probes that increase the depth of investigation. The interpretation of logging data with respect to fractures is typically guided by practical experience rather than theory and is often ambiguous. We use remote acoustic reflection logging data and high-order finite-difference approximations in the forward modeling and prestack reverse-time migration to image fractures. First, we perform forward modeling of the fracture responses as a function of the fracture-borehole wall distance, aperture, and dip angle. Second, we extract the energy intensity within the imaging area to determine whether the fracture can be identified as the formation velocity is varied. Finally, we evaluate the effect of the fracture-borehole distance, fracture aperture, and dip angle on fracture identification.

  17. Geophysical evaluation of sandstone aquifers in the Reconcavo-Tucano Basin, Bahia -- Brazil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lima, O.A.L. de

    1993-11-01

    The upper clastic sediments in the Reconcavo-Tucano basin comprise a multilayer aquifer system of Jurassic age. Its groundwater is normally fresh down to depths of more than 1,000 m. Locally, however, there are zones producing high salinity or sulfur geothermal water. Analysis of electrical logs of more than 150 wells enabled the identification of the most typical sedimentary structures and the gross geometries for the sandstone units in selected areas of the basin. Based on this information, the thick sands are interpreted as coalescent point bars and the shales as flood plain deposits of a large fluvial environment. The resistivitymore » logs and core laboratory data are combined to develop empirical equations relating aquifer porosity and permeability to log-derived parameters such as formation factor and cementation exponent. Temperature logs of 15 wells were useful to quantify the water leakage through semiconfining shales. The groundwater quality was inferred from spontaneous potential (SP) log deflections under control of chemical analysis of water samples. An empirical chart is developed that relates the SP-derived water resistivity to the true water resistivity within the formations. The patterns of salinity variation with depth inferred from SP logs were helpful in identifying subsurface flows along major fault zones, where extensive mixing of water is taking place. A total of 49 vertical Schlumberger resistivity soundings aid in defining aquifer structures and in extrapolating the log derived results. Transition zones between fresh and saline waters have also been detected based on a combination of logging and surface sounding data. Ionic filtering by water leakage across regional shales, local convection and mixing along major faults and hydrodynamic dispersion away from lateral permeability contrasts are the main mechanisms controlling the observed distributions of salinity and temperature within the basin.« less

  18. An integrated 3D log processing optimization system for small sawmills in central Appalachia

    Treesearch

    Wenshu Lin; Jingxin Wang

    2013-01-01

    An integrated 3D log processing optimization system was developed to perform 3D log generation, opening face determination, headrig log sawing simulation, fl itch edging and trimming simulation, cant resawing, and lumber grading. A circular cross-section model, together with 3D modeling techniques, was used to reconstruct 3D virtual logs. Internal log defects (knots)...

  19. A comparison of the survival of F+RNA and F+DNA coliphages in lake water microcosms.

    PubMed

    Long, Sharon C; Sobsey, Mark D

    2004-03-01

    The survival of seven F+RNA phages (MS2 Group I ATCC type strain, two Group I environmental isolates, a Group II environmental isolate, a Group III environmental isolate, and two Group IV environmental isolates) and six F+DNA phages (M13, fd, f1, and ZJ/2 ATCC type strains, and two environmental isolates) were examined in microcosms using a surface drinking water source. Phages were spiked into replicate aliquots of a source water at about 20,000 pfu/ml. Replicate spikes were incubated at 4 and 20 degrees C and monitored for 110 days. At 4 degrees C, Groups I and II F+ RNA phages were detectable through 110 days, with reductions of about 1 and 3 log10, respectively. The Group III F+RNA phage demonstrated 5 log10 reduction after 3 weeks, and the Group IV F+RNA phages were reduced to detection limits (5 log10 reduction) within 10 days. Of the F+DNA phages, all four type strains were detectable with about 2.5 log10 reduction after 110 days at 4 degrees C. The F+DNA environmental isolates were detectable with about a 4 log10 reduction after 110 days at 4 degrees C. All phages demonstrated faster decay at 20 degrees C. These results suggest that differences in F+ phage survival may influence their prevalence in environmental waters and the ability to attribute their prevalence to specific human and animal sources of faecal contamination.

  20. A Varian DynaLog file-based procedure for patient dose-volume histogram-based IMRT QA.

    PubMed

    Calvo-Ortega, Juan F; Teke, Tony; Moragues, Sandra; Pozo, Miquel; Casals-Farran, Joan

    2014-03-06

    In the present study, we describe a method based on the analysis of the dynamic MLC log files (DynaLog) generated by the controller of a Varian linear accelerator in order to perform patient-specific IMRT QA. The DynaLog files of a Varian Millennium MLC, recorded during an IMRT treatment, can be processed using a MATLAB-based code in order to generate the actual fluence for each beam and so recalculate the actual patient dose distribution using the Eclipse treatment planning system. The accuracy of the DynaLog-based dose reconstruction procedure was assessed by introducing ten intended errors to perturb the fluence of the beams of a reference plan such that ten subsequent erroneous plans were generated. In-phantom measurements with an ionization chamber (ion chamber) and planar dose measurements using an EPID system were performed to investigate the correlation between the measured dose changes and the expected ones detected by the reconstructed plans for the ten intended erroneous cases. Moreover, the method was applied to 20 cases of clinical plans for different locations (prostate, lung, breast, and head and neck). A dose-volume histogram (DVH) metric was used to evaluate the impact of the delivery errors in terms of dose to the patient. The ionometric measurements revealed a significant positive correlation (R² = 0.9993) between the variations of the dose induced in the erroneous plans with respect to the reference plan and the corresponding changes indicated by the DynaLog-based reconstructed plans. The EPID measurements showed that the accuracy of the DynaLog-based method to reconstruct the beam fluence was comparable with the dosimetric resolution of the portal dosimetry used in this work (3%/3 mm). The DynaLog-based reconstruction method described in this study is a suitable tool to perform a patient-specific IMRT QA. This method allows us to perform patient-specific IMRT QA by evaluating the result based on the DVH metric of the planning CT image (patient DVH-based IMRT QA).

  1. The XMM-Newton Wide-Field Survey in the COSMOS Field. II. X-Ray Data and the logN-logS Relations

    NASA Astrophysics Data System (ADS)

    Cappelluti, N.; Hasinger, G.; Brusa, M.; Comastri, A.; Zamorani, G.; Böhringer, H.; Brunner, H.; Civano, F.; Finoguenov, A.; Fiore, F.; Gilli, R.; Griffiths, R. E.; Mainieri, V.; Matute, I.; Miyaji, T.; Silverman, J.

    2007-09-01

    We present data analysis and X-ray source counts for the first season of XMM-Newton observations in the COSMOS field. The survey covers ~2 deg2 within the region of sky bounded by 09h57m30s

  2. Multilaboratory comparison of hepatitis C virus viral load assays.

    PubMed

    Caliendo, A M; Valsamakis, A; Zhou, Y; Yen-Lieberman, B; Andersen, J; Young, S; Ferreira-Gonzalez, A; Tsongalis, G J; Pyles, R; Bremer, J W; Lurain, N S

    2006-05-01

    We report a multilaboratory evaluation of hepatitis C virus (HCV) viral load assays to determine their linear range, reproducibility, subtype detection, and agreement. A panel of HCV RNA samples ranging in nominal concentration from 1.0 to 7.0 log10 IU/ml was constructed by diluting a clinical specimen (genotype 1b). Replicates of the panel were tested in multiple laboratories using the Abbott TaqMan analyte-specific reagent (Abbott reverse transcription-PCR [RT-PCR]), Roche TaqMan RUO (Roche RT-PCR), Roche Amplicor Monitor HCV 2.0 (Roche Monitor), and Bayer VERSANT HCV RNA 3.0 (Bayer bDNA) assays. Bayer bDNA-negative specimens were tested reflexively using the Bayer VERSANT HCV RNA qualitative assay (Bayer TMA). Abbott RT-PCR and Roche RT-PCR detected all 28 replicates with a concentration of 1.0 log10 IU/ml and were linear to 7.0 log10 IU/ml. Roche Monitor and Bayer bDNA detected 27 out of 28 and 13 out of 28 replicates, respectively, of 3.0 log10 IU/ml. Bayer TMA detected all seven replicates with 1.0 log10 IU/ml. Bayer bDNA was the most reproducible of the four assays. The mean viral load values for panel members in the linear ranges of the assays were within 0.5 log10 for the different tests. Eighty-nine clinical specimens of various genotypes (1 through 4) were tested in the Bayer bDNA, Abbott RT-PCR, and Roche RT-PCR assays. For Abbott RT-PCR, mean viral load values were 0.61 to 0.96 log10 greater than the values for Bayer bDNA assay for samples with genotype 1, 2, or 3 samples and 0.08 log10 greater for genotype 4 specimens. The Roche RT-PCR assay gave mean viral load values that were 0.28 to 0.82 log10 greater than those obtained with the Bayer bDNA assay for genotype 1, 2, and 3 samples. However, for genotype 4 samples the mean viral load value obtained with the Roche RT-PCR assay was, on average, 0.15 log10 lower than that of the Bayer bDNA. Based on these data, we conclude that the sensitivity and linear range of the Abbott and Roche RT-PCR assays enable them to be used for HCV diagnostics and therapeutic monitoring. However, the differences in the viral load values obtained with the different assays underscore the importance of using one assay when monitoring response to therapy.

  3. Estimates of Social Contact in a Middle School Based on Self-Report and Wireless Sensor Data

    PubMed Central

    Leecaster, Molly; Toth, Damon J. A.; Pettey, Warren B. P.; Rainey, Jeanette J.; Gao, Hongjiang; Uzicanin, Amra; Samore, Matthew

    2016-01-01

    Estimates of contact among children, used for infectious disease transmission models and understanding social patterns, historically rely on self-report logs. Recently, wireless sensor technology has enabled objective measurement of proximal contact and comparison of data from the two methods. These are mostly small-scale studies, and knowledge gaps remain in understanding contact and mixing patterns and also in the advantages and disadvantages of data collection methods. We collected contact data from a middle school, with 7th and 8th grades, for one day using self-report contact logs and wireless sensors. The data were linked for students with unique initials, gender, and grade within the school. This paper presents the results of a comparison of two approaches to characterize school contact networks, wireless proximity sensors and self-report logs. Accounting for incomplete capture and lack of participation, we estimate that “sensor-detectable”, proximal contacts longer than 20 seconds during lunch and class-time occurred at 2 fold higher frequency than “self-reportable” talk/touch contacts. Overall, 55% of estimated talk-touch contacts were also sensor-detectable whereas only 15% of estimated sensor-detectable contacts were also talk-touch. Contacts detected by sensors and also in self-report logs had longer mean duration than contacts detected only by sensors (6.3 vs 2.4 minutes). During both lunch and class-time, sensor-detectable contacts demonstrated substantially less gender and grade assortativity than talk-touch contacts. Hallway contacts, which were ascertainable only by proximity sensors, were characterized by extremely high degree and short duration. We conclude that the use of wireless sensors and self-report logs provide complementary insight on in-school mixing patterns and contact frequency. PMID:27100090

  4. Effect of lime juice on Vibrio parahaemolyticus and Salmonella enterica inactivation during the preparation of the raw fish dish ceviche.

    PubMed

    Mathurand, Prateek; Schaffner, Donald W

    2013-06-01

    Ceviche is a raw fish dish common in Peru and other Latin American counties. The most characteristic feature of ceviche is the use of lime juice for marinating or "cooking" the raw fish. Confirmed cases of cholera in Peru, New Jersey, and Florida have been associated with ceviche. Although the effect of organic acids on pathogenic bacteria has been well characterized, few data exist on the effect of these acids in seafood systems. The objective of the study was to evaluate the effects of lime juice marination on pathogens likely to be present in ceviche. Tilapia (Oreochromis niloticus) fillet pieces were inoculated with Vibrio parahaemolyticus and Salmonella enterica (>7 log CFU/g) and incubated at 25 and 4°C for 30 or 120 min in the presence of fresh lime juice at concentrations typical for the preparation of ceviche. Similar levels of cells were also inoculated into fresh lime juice without tilapia. Surviving cells were enumerated on selective (xylose lysine Tergitol 4 and thiosulfate-bile-citrate-sucrose) and nonselective (tryptic soy agar) media. V. parahaemolyticus levels were reduced to below detection limits (∼5-log reduction) under all conditions studied. Salmonella strains on tilapia were much more resistant to inactivation and were only slightly reduced (∼1- to 2-log reduction). Salmonella and V. parahaemolyticus inoculated directly into lime juice without tilapia were all reduced to below detection limits (∼5-log reduction). A typical ceviche recipe reduces V. parahaemolyticus risk significantly but is less effective for control of S. enterica.

  5. Choice of Grating Orientation for Evaluation of Peripheral Vision

    PubMed Central

    Venkataraman, Abinaya Priya; Winter, Simon; Rosén, Robert; Lundström, Linda

    2016-01-01

    ABSTRACT Purpose Peripheral resolution acuity depends on the orientation of the stimuli. However, it is uncertain if such a meridional effect also exists for peripheral detection tasks because they are affected by optical errors. Knowledge of the quantitative differences in acuity for different grating orientations is crucial for choosing the appropriate stimuli for evaluations of peripheral resolution and detection tasks. We assessed resolution and detection thresholds for different grating orientations in the peripheral visual field. Methods Resolution and detection thresholds were evaluated for gratings of four different orientations in eight different visual field meridians in the 20-deg visual field in white light. Detection measurements in monochromatic light (543 nm; bandwidth, 10 nm) were also performed to evaluate the effects of chromatic aberration on the meridional effect. A combination of trial lenses and adaptive optics system was used to correct the monochromatic lower- and higher-order aberrations. Results For both resolution and detection tasks, gratings parallel to the visual field meridian had better threshold compared with the perpendicular gratings, whereas the two oblique gratings had similar thresholds. The parallel and perpendicular grating acuity differences for resolution and detection tasks were 0.16 logMAR and 0.11 logMAD, respectively. Elimination of chromatic errors did not affect the meridional preference in detection acuity. Conclusions Similar to peripheral resolution, detection also shows a meridional effect that appears to have a neural origin. The threshold difference seen for parallel and perpendicular gratings suggests the use of two oblique gratings as stimuli in alternative forced-choice procedures for peripheral vision evaluation to reduce measurement variation. PMID:26889822

  6. Choice of Grating Orientation for Evaluation of Peripheral Vision.

    PubMed

    Venkataraman, Abinaya Priya; Winter, Simon; Rosén, Robert; Lundström, Linda

    2016-06-01

    Peripheral resolution acuity depends on the orientation of the stimuli. However, it is uncertain if such a meridional effect also exists for peripheral detection tasks because they are affected by optical errors. Knowledge of the quantitative differences in acuity for different grating orientations is crucial for choosing the appropriate stimuli for evaluations of peripheral resolution and detection tasks. We assessed resolution and detection thresholds for different grating orientations in the peripheral visual field. Resolution and detection thresholds were evaluated for gratings of four different orientations in eight different visual field meridians in the 20-deg visual field in white light. Detection measurements in monochromatic light (543 nm; bandwidth, 10 nm) were also performed to evaluate the effects of chromatic aberration on the meridional effect. A combination of trial lenses and adaptive optics system was used to correct the monochromatic lower- and higher-order aberrations. For both resolution and detection tasks, gratings parallel to the visual field meridian had better threshold compared with the perpendicular gratings, whereas the two oblique gratings had similar thresholds. The parallel and perpendicular grating acuity differences for resolution and detection tasks were 0.16 logMAR and 0.11 logMAD, respectively. Elimination of chromatic errors did not affect the meridional preference in detection acuity. Similar to peripheral resolution, detection also shows a meridional effect that appears to have a neural origin. The threshold difference seen for parallel and perpendicular gratings suggests the use of two oblique gratings as stimuli in alternative forced-choice procedures for peripheral vision evaluation to reduce measurement variation.

  7. Findings from Matching VIIRS Boat Detection and VMS Data

    NASA Astrophysics Data System (ADS)

    Hsu, F. C.; Elvidge, C.; Zhizhin, M. N.; Baugh, K.; Ghosh, T.

    2017-12-01

    With the superior nigthtime sensitivity and spatial resolution provided by VIIRS Day Night Band, we had developed algorithm known as VIIRS Boat Detection (VBD) to detect fishing vessels active at night using light to attract schools of fish. While VBD is effective in finding bright boats, little is known on the nature of boats that emits such bright lights. To complement the missing attribute of VBD detections, the authors find aid from Vessel Monitoring System (VMS) data. VMS is widely used in monitoring fishing vessels logging their coordinate nominally every hour, along with vessel specifications such as tonnage, size, and gear type. This study matches VMS records with VBD detections, broadening the understanding of the lighting streategy used by fisherman, and provide valuable assumption on possible vessel types for VBD detections.

  8. Storage of sparse files using parallel log-structured file system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bent, John M.; Faibish, Sorin; Grider, Gary

    A sparse file is stored without holes by storing a data portion of the sparse file using a parallel log-structured file system; and generating an index entry for the data portion, the index entry comprising a logical offset, physical offset and length of the data portion. The holes can be restored to the sparse file upon a reading of the sparse file. The data portion can be stored at a logical end of the sparse file. Additional storage efficiency can optionally be achieved by (i) detecting a write pattern for a plurality of the data portions and generating a singlemore » patterned index entry for the plurality of the patterned data portions; and/or (ii) storing the patterned index entries for a plurality of the sparse files in a single directory, wherein each entry in the single directory comprises an identifier of a corresponding sparse file.« less

  9. Comparative effectiveness of membrane bioreactors, conventional secondary treatment, and chlorine and UV disinfection to remove microorganisms from municipal wastewaters.

    PubMed

    Francy, Donna S; Stelzer, Erin A; Bushon, Rebecca N; Brady, Amie M G; Williston, Ashley G; Riddell, Kimberly R; Borchardt, Mark A; Spencer, Susan K; Gellner, Terry M

    2012-09-01

    Log removals of bacterial indicators, coliphage, and enteric viruses were studied in three membrane bioreactor (MBR) activated-sludge and two conventional secondary activated-sludge municipal wastewater treatment plants during three recreational seasons (May-Oct.) when disinfection of effluents is required. In total, 73 regular samples were collected from key locations throughout treatment processes: post-preliminary, post-MBR, post-secondary, post-tertiary, and post-disinfection (UV or chlorine). Out of 19 post-preliminary samples, adenovirus by quantitative polymerase chain reaction (qPCR) was detected in all 19, enterovirus by quantitative reverse transcription polymerase chain reaction (qRT-PCR) was detected in 15, and norovirus GI by qRT-PCR was detected in 11. Norovirus GII and Hepatitis A virus were not detected in any samples, and rotavirus was detected in one sample but could not be quantified. Although culturable viruses were found in 12 out of 19 post-preliminary samples, they were not detected in any post-secondary, post-MBR, post-ultraviolet, or post-chlorine samples. Median log removals for all organisms were higher for MBR secondary treatment (3.02 to >6.73) than for conventional secondary (1.53-4.19) treatment. Ultraviolet disinfection after MBR treatment provided little additional log removal of any organism except for somatic coliphage (>2.18), whereas ultraviolet or chlorine disinfection after conventional secondary treatment provided significant log removals (above the analytical variability) of all bacterial indicators (1.18-3.89) and somatic and F-specific coliphage (0.71 and >2.98). Median log removals of adenovirus across disinfection were low in both MBR and conventional secondary plants (no removal detected and 0.24), and few removals of individual samples were near or above the analytical variability of 1.2 log genomic copies per liter. Based on qualitative examinations of plots showing reductions of organisms throughout treatment processes, somatic coliphage may best represent the removal of viruses across secondary treatment in both MBR and conventional secondary plants. F-specific coliphage and Escherichia coli may best represent the removal of viruses across the disinfection process in MBR facilities, but none of the indicators represented the removal of viruses across disinfection in conventional secondary plants. Published by Elsevier Ltd.

  10. Comparative effectiveness of membrane bioreactors, conventional secondary treatment, and chlorine and UV disinfection to remove microorganisms from municipal wastewaters

    USGS Publications Warehouse

    Francy, Donna S.; Erin, A. Stelzer; Bushon, Rebecca N.; Brady, Amie M.G.; Williston, Ashley G.; Riddell, Kimberly R.; Borchardt, Mark A.; Spencer, Susan K.; Gellner, Terry M.

    2012-01-01

    Log removals of bacterial indicators, coliphage, and enteric viruses were studied in three membrane bioreactor (MBR) activated-sludge and two conventional secondary activated-sludge municipal wastewater treatment plants during three recreational seasons (May-Oct.) when disinfection of effluents is required. In total, 73 regular samples were collected from key locations throughout treatment processes: post-preliminary, post-MBR, post-secondary, post-tertiary, and post-disinfection (UV or chlorine). Out of 19 post-preliminary samples, adenovirus by quantitative polymerase chain reaction (qPCR) was detected in all 19, enterovirus by quantitative reverse transcription polymerase chain reaction (qRT-PCR) was detected in 15, and norovirus GI by qRT-PCR was detected in 11. Norovirus GII and Hepatitis A virus were not detected in any samples, and rotavirus was detected in one sample but could not be quantified. Although culturable viruses were found in 12 out of 19 post-preliminary samples, they were not detected in any post-secondary, post-MBR, post-ultraviolet, or post-chlorine samples. Median log removals for all organisms were higher for MBR secondary treatment (3.02 to >6.73) than for conventional secondary (1.53-4.19) treatment. Ultraviolet disinfection after MBR treatment provided little additional log removal of any organism except for somatic coliphage (>2.18), whereas ultraviolet or chlorine disinfection after conventional secondary treatment provided significant log removals (above the analytical variability) of all bacterial indicators (1.18-3.89) and somatic and F-specific coliphage (0.71 and >2.98). Median log removals of adenovirus across disinfection were low in both MBR and conventional secondary plants (no removal detected and 0.24), and few removals of individual samples were near or above the analytical variability of 1.2 log genomic copies per liter. Based on qualitative examinations of plots showing reductions of organisms throughout treatment processes, somatic coliphage may best represent the removal of viruses across secondary treatment in both MBR and conventional secondary plants. F-specific coliphage and Escherichia coli may best represent the removal of viruses across the disinfection process in MBR facilities, but none of the indicators represented the removal of viruses across disinfection in conventional secondary plants.

  11. European Multicenter Study on Analytical Performance of DxN Veris System HCV Assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Gismondo, Maria Rita; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Marcos, Maria Angeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-04-01

    The analytical performance of the Veris HCV Assay for use on the new and fully automated Beckman Coulter DxN Veris Molecular Diagnostics System (DxN Veris System) was evaluated at 10 European virology laboratories. Precision, analytical sensitivity, specificity, and performance with negative samples, linearity, and performance with hepatitis C virus (HCV) genotypes were evaluated. Precision for all sites showed a standard deviation (SD) of 0.22 log 10 IU/ml or lower for each level tested. Analytical sensitivity determined by probit analysis was between 6.2 and 9.0 IU/ml. Specificity on 94 unique patient samples was 100%, and performance with 1,089 negative samples demonstrated 100% not-detected results. Linearity using patient samples was shown from 1.34 to 6.94 log 10 IU/ml. The assay demonstrated linearity upon dilution with all HCV genotypes. The Veris HCV Assay demonstrated an analytical performance comparable to that of currently marketed HCV assays when tested across multiple European sites. Copyright © 2017 American Society for Microbiology.

  12. A new estimation of HD/2H2 at high redshift using the spectrum of the quasar J 2123-0050

    NASA Astrophysics Data System (ADS)

    Klimenko, V. V.; Balashev, S. A.; Ivanchik, A. V.; Varshalovich, D. A.

    2015-12-01

    We present a new analysis of the quasar spectrum J 2123-0050 obtained using VLT/UVES. The H2/HD absorption system at z = 2.059 was analysed. This system consists of two subsystems with zA = 2.05933 and zB = 2.05955. The HD lines have been detected only in subsystem A with the column density of log N = 13.87 ± 0.06. We have determined the column density of H2 in this subsystem, log N = 17.93 ± 0.01, which is about three times larger than estimation derived early from analyses of quasar spectrum obtained using KECK/HIRES [1]. The derived ratio HD/2H2 = (4.28 ± 0.60) × 10-5 is the largest in quasar spectra, nevertheless it coincides with the primordial deuterium abundance within 2σ error. Additionally, we have found some evidence in the partial covering effect for the H2 system.

  13. TH-AB-201-12: Using Machine Log-Files for Treatment Planning and Delivery QA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stanhope, C; Liang, J; Drake, D

    2016-06-15

    Purpose: To determine the segment reduction and dose resolution necessary for machine log-files to effectively replace current phantom-based patient-specific quality assurance, while minimizing computational cost. Methods: Elekta’s Log File Convertor R3.2 records linac delivery parameters (dose rate, gantry angle, leaf position) every 40ms. Five VMAT plans [4 H&N, 1 Pulsed Brain] comprised of 2 arcs each were delivered on the ArcCHECK phantom. Log-files were reconstructed in Pinnacle on the phantom geometry using 1/2/3/4° control point spacing and 2/3/4mm dose grid resolution. Reconstruction effectiveness was quantified by comparing 2%/2mm gamma passing rates of the original and log-file plans. Modulation complexity scoresmore » (MCS) were calculated for each beam to correlate reconstruction accuracy and beam modulation. Percent error in absolute dose for each plan-pair combination (log-file vs. ArcCHECK, original vs. ArcCHECK, log-file vs. original) was calculated for each arc and every diode greater than 10% of the maximum measured dose (per beam). Comparing standard deviations of the three plan-pair distributions, relative noise of the ArcCHECK and log-file systems was elucidated. Results: The original plans exhibit a mean passing rate of 95.1±1.3%. The eight more modulated H&N arcs [MCS=0.088±0.014] and two less modulated brain arcs [MCS=0.291±0.004] yielded log-file pass rates most similar to the original plan when using 1°/2mm [0.05%±1.3% lower] and 2°/3mm [0.35±0.64% higher] log-file reconstructions respectively. Log-file and original plans displayed percent diode dose errors 4.29±6.27% and 3.61±6.57% higher than measurement. Excluding the phantom eliminates diode miscalibration and setup errors; log-file dose errors were 0.72±3.06% higher than the original plans – significantly less noisy. Conclusion: For log-file reconstructed VMAT arcs, 1° control point spacing and 2mm dose resolution is recommended, however, less modulated arcs may allow less stringent reconstructions. Following the aforementioned reconstruction recommendations, the log-file technique is capable of detecting delivery errors with equivalent accuracy and less noise than ArcCHECK QA. I am funded by an Elekta Research Grant.« less

  14. Binary Logistic Regression Analysis for Detecting Differential Item Functioning: Effectiveness of R[superscript 2] and Delta Log Odds Ratio Effect Size Measures

    ERIC Educational Resources Information Center

    Hidalgo, Mª Dolores; Gómez-Benito, Juana; Zumbo, Bruno D.

    2014-01-01

    The authors analyze the effectiveness of the R[superscript 2] and delta log odds ratio effect size measures when using logistic regression analysis to detect differential item functioning (DIF) in dichotomous items. A simulation study was carried out, and the Type I error rate and power estimates under conditions in which only statistical testing…

  15. Automated knot detection with visual post-processing of Douglas-fir veneer images

    Treesearch

    C.L. Todoroki; Eini C. Lowell; Dennis Dykstra

    2010-01-01

    Knots on digital images of 51 full veneer sheets, obtained from nine peeler blocks crosscut from two 35-foot (10.7 m) long logs and one 18-foot (5.5 m) log from a single Douglas-fir tree, were detected using a two-phase algorithm. The algorithm was developed using one image, the Development Sheet, refined on five other images, the Training Sheets, and then applied to...

  16. Estimation of the POD function and the LOD of a qualitative microbiological measurement method.

    PubMed

    Wilrich, Cordula; Wilrich, Peter-Theodor

    2009-01-01

    Qualitative microbiological measurement methods in which the measurement results are either 0 (microorganism not detected) or 1 (microorganism detected) are discussed. The performance of such a measurement method is described by its probability of detection as a function of the contamination (CFU/g or CFU/mL) of the test material, or by the LOD(p), i.e., the contamination that is detected (measurement result 1) with a specified probability p. A complementary log-log model was used to statistically estimate these performance characteristics. An intralaboratory experiment for the detection of Listeria monocytogenes in various food matrixes illustrates the method. The estimate of LOD50% is compared with the Spearman-Kaerber method.

  17. New radio meteor detecting and logging software

    NASA Astrophysics Data System (ADS)

    Kaufmann, Wolfgang

    2017-08-01

    A new piece of software ``Meteor Logger'' for the radio observation of meteors is described. It analyses an incoming audio stream in the frequency domain to detect a radio meteor signal on the basis of its signature, instead of applying an amplitude threshold. For that reason the distribution of the three frequencies with the highest spectral power are considered over the time (3f method). An auto notch algorithm is developed to prevent the radio meteor signal detection from being jammed by a present interference line. The results of an exemplary logging session are discussed.

  18. Detection of anomalous events

    DOEpatents

    Ferragut, Erik M.; Laska, Jason A.; Bridges, Robert A.

    2016-06-07

    A system is described for receiving a stream of events and scoring the events based on anomalousness and maliciousness (or other classification). The system can include a plurality of anomaly detectors that together implement an algorithm to identify low-probability events and detect atypical traffic patterns. The anomaly detector provides for comparability of disparate sources of data (e.g., network flow data and firewall logs.) Additionally, the anomaly detector allows for regulatability, meaning that the algorithm can be user configurable to adjust a number of false alerts. The anomaly detector can be used for a variety of probability density functions, including normal Gaussian distributions, irregular distributions, as well as functions associated with continuous or discrete variables.

  19. Molecular detection of Acanthamoeba spp., Naegleria fowleri and Vermamoeba (Hartmannella) vermiformis as vectors for Legionella spp. in untreated and solar pasteurized harvested rainwater.

    PubMed

    Dobrowsky, Penelope H; Khan, Sehaam; Cloete, Thomas E; Khan, Wesaal

    2016-10-10

    Legionella spp. employ multiple strategies to adapt to stressful environments including the proliferation in protective biofilms and the ability to form associations with free-living amoeba (FLA). The aim of the current study was to identify Legionella spp., Acanthamoeba spp., Vermamoeba (Hartmannella) vermiformis and Naegleria fowleri that persist in a harvested rainwater and solar pasteurization treatment system. Pasteurized (45 °C, 65 °C, 68 °C, 74 °C, 84 °C and 93 °C) and unpasteurized tank water samples were screened for Legionella spp. and the heterotrophic plate count was enumerated. Additionally, ethidium monoazide quantitative polymerase chain reaction (EMA-qPCR) was utilized for the quantification of viable Legionella spp., Acanthamoeba spp., V. vermiformis and N. fowleri in pasteurized (68 °C, 74 °C, 84 °C and 93 °C) and unpasteurized tank water samples, respectively. Of the 82 Legionella spp. isolated from unpasteurized tank water samples, Legionella longbeachae (35 %) was the most frequently isolated, followed by Legionella norrlandica (27 %) and Legionella rowbothamii (4 %). Additionally, a positive correlation was recorded between the heterotrophic plate count vs. the number of Legionella spp. detected (ρ = 0.710, P = 0.048) and the heterotrophic plate count vs. the number of Legionella spp. isolated (ρ = 0.779, P = 0.0028) from the tank water samples collected. Solar pasteurization was effective in reducing the gene copies of viable V. vermiformis (3-log) and N. fowleri (5-log) to below the lower limit of detection at temperatures of 68-93 °C and 74-93 °C, respectively. Conversely, while the gene copies of viable Legionella and Acanthamoeba were significantly reduced by 2-logs (P = 0.0024) and 1-log (P = 0.0015) overall, respectively, both organisms were still detected after pasteurization at 93 °C. Results from this study indicate that Acanthamoeba spp. primarily acts as the vector and aids in the survival of Legionella spp. in the solar pasteurized rainwater as both organisms were detected and were viable at high temperatures (68-93 °C).

  20. Microbiological contamination of dried and lyophilized garlic as a potential source of food spoilage.

    PubMed

    Kłębukowska, Lucyna; Zadernowska, Anna; Chajęcka-Wierzchowska, Wioleta

    2015-03-01

    Garlic is valued more for its flavoring and used in a wide variety of foods. In food technology, fresh garlic is not used, but instead its processed forms, most often dried and lyophilized, are utilized. The quality and safety of the final product largely depends on their microbiological quality. This research has provided information about effect of garlic fixation methods and provided information about effect of microbiological contamination of garlic used as a spice for quality of garlic mayonnaise sauce. The authors decided to undertake studies following a report from one of the manufacturers of garlic sauces on product defects which originated in dried garlic used in the production process. Samples of garlic (n = 26) were examinated using standard cultural methods (counts of fungi, lactic acid bacteria-LAB, spore-producing Bacillus sp. and the presence of anaerobic saccharolytic and proteolytic clostridia), automated system TEMPO (total viable count, Enterobacteriaceae), immunoenzymatic method using VIDAS tests (occurrence of Salmonella sp. and Listeria monocytogenes). The number of total viable count was ranged from 3.51 to 6.85 log CFU/g. Enterobacteriaceae were detected only in one sample. Comparably low values were recorded for fungi (1.30 to 3.47 log CFU/g). The number of LAB was ranged from 2.34 to 5.49 log CFU/g. Clostridium sp. were detected in 22 samples. Salmonella sp. and Listeria monocytogenes were not detected. It was found that garlic, regardless of th preservation procedure, might be a source of contamination of garlic mayonnaise sauce especially with lactic acid bacteria and Clostridium sp. spores.

  1. Aerobic plate counts and ATP levels correlate with Listeria monocytogenes detection in retail delis.

    PubMed

    Hammons, Susan R; Stasiewicz, Matthew J; Roof, Sherry; Oliver, Haley F

    2015-04-01

    Listeria monocytogenes is a foodborne pathogen that causes an estimated 1,591 cases of illness and 255 deaths annually in the United States, the majority of which are attributed to ready-to-eat deli meats processed in retail delis. Because retail delis distribute product directly to consumers, rapid methods to validate cleaning and sanitation are needed to improve retail food safety. This study investigated the relationships among ATP levels, standard aerobic plate count (APC), and L. monocytogenes presence in fully operational delis. Fifteen full-service delis were concurrently sampled for ATP, APC, and L. monocytogenes during preoperational hours once monthly for 3 months. Fifteen additional delis were recruited for 6 months of operational sampling (n = 30). A 1-log increase in APC was equivalent to a 3.3-fold increase in the odds of detecting L. monocytogenes (P < 0.001) and a 1.9-log increase in L monocytogenes population (P = 0.03). An ATP level increase of 1 log relative light unit correlated to a 0.22-log increase in APC (P < 0.001). A preoperational ATP level mean increase by 1 log relative light unit increased the odds of detecting L. monocytogenes concurrently fourfold. A 0.5-log increase in mean ATP level during preoperational sampling corresponded to a 2% increase in the predicted L. monocytogenes prevalence during operation (P < 0.01). Additionally, 10 statistically representative sites were identified and recommended for use in sanitation monitoring programs. Our data support the use of ATP as a rapid method to validate effective cleaning and sanitation to reduce L. monocytogenes in retail delis.

  2. Evaluating the performance of the quick CSF method in detecting contrast sensitivity function changes

    PubMed Central

    Hou, Fang; Lesmes, Luis Andres; Kim, Woojae; Gu, Hairong; Pitt, Mark A.; Myung, Jay I.; Lu, Zhong-Lin

    2016-01-01

    The contrast sensitivity function (CSF) has shown promise as a functional vision endpoint for monitoring the changes in functional vision that accompany eye disease or its treatment. However, detecting CSF changes with precision and efficiency at both the individual and group levels is very challenging. By exploiting the Bayesian foundation of the quick CSF method (Lesmes, Lu, Baek, & Albright, 2010), we developed and evaluated metrics for detecting CSF changes at both the individual and group levels. A 10-letter identification task was used to assess the systematic changes in the CSF measured in three luminance conditions in 112 naïve normal observers. The data from the large sample allowed us to estimate the test–retest reliability of the quick CSF procedure and evaluate its performance in detecting CSF changes at both the individual and group levels. The test–retest reliability reached 0.974 with 50 trials. In 50 trials, the quick CSF method can detect a medium 0.30 log unit area under log CSF change with 94.0% accuracy at the individual observer level. At the group level, a power analysis based on the empirical distribution of CSF changes from the large sample showed that a very small area under log CSF change (0.025 log unit) could be detected by the quick CSF method with 112 observers and 50 trials. These results make it plausible to apply the method to monitor the progression of visual diseases or treatment effects on individual patients and greatly reduce the time, sample size, and costs in clinical trials at the group level. PMID:27120074

  3. The algorithm for automatic detection of the calibration object

    NASA Astrophysics Data System (ADS)

    Artem, Kruglov; Irina, Ugfeld

    2017-06-01

    The problem of the automatic image calibration is considered in this paper. The most challenging task of the automatic calibration is a proper detection of the calibration object. The solving of this problem required the appliance of the methods and algorithms of the digital image processing, such as morphology, filtering, edge detection, shape approximation. The step-by-step process of the development of the algorithm and its adopting to the specific conditions of the log cuts in the image's background is presented. Testing of the automatic calibration module was carrying out under the conditions of the production process of the logging enterprise. Through the tests the average possibility of the automatic isolating of the calibration object is 86.1% in the absence of the type 1 errors. The algorithm was implemented in the automatic calibration module within the mobile software for the log deck volume measurement.

  4. Physicochemical formation conditions of silver sulfoselenides at the Rogovik deposit, Northeastern Russia

    NASA Astrophysics Data System (ADS)

    Zhuravkova, T. V.; Palyanova, G. A.; Kravtsova, R. G.

    2015-07-01

    The chemical compositions of acanthite, naumannite, and associated ore minerals have been studied from the samples of polychronous Au-Ag ores at the Rogovik deposit. The following admixtures have been detected: S in naumannite (0-2.9 wt %), Se in acanthite (0-7.45 wt %), argyrodite (~4.8 wt %), and galena (~3.1 wt %), and Fe in sphalerite (~1.2 wt %). The physicochemical parameters of ore formation have been reconstructed on the basis of mineralogical and geochemical data and thermodynamic calculations. Eh-pH (25°C, 1 bar), log fO2-pH, log fS2- T, log fSe2- T, and log fS2-log fSe2 (100-300°C, 1-300 bars) diagrams for the Ag-S-Se-H2O system with the stability fields of Ag sulfoselenides Ag2S1- x Se x of various composition (step x = 0.25, where 0 ≤ x ≤ 1) have been calculated for the first time. It has been established that Ag sulfoselenides of the naumannite series from polychronous ores of the Rogovik deposit precipitated below 70-133°C under reductive conditions (log fO2 =-65…-50) from near-neutral solutions containing elevated Se and relatively lowered S. It has been established that Ag sulfoselenides of acanthite series were formed later then naumannite but in the same range of log fO2 values at temperatures below 110-177°C from solutions with high S concentration and relatively lowered concentration of Se. The complex composition of the studied Au-Ag ores, whose characteristic feature is extremely variable mineralogy, is confirmed.

  5. Detection of complex cyber attacks

    NASA Astrophysics Data System (ADS)

    Gregorio-de Souza, Ian; Berk, Vincent H.; Giani, Annarita; Bakos, George; Bates, Marion; Cybenko, George; Madory, Doug

    2006-05-01

    One significant drawback to currently available security products is their inabilty to correlate diverse sensor input. For instance, by only using network intrusion detection data, a root kit installed through a weak username-password combination may go unnoticed. Similarly, an administrator may never make the link between deteriorating response times from the database server and an attacker exfiltrating trusted data, if these facts aren't presented together. Current Security Information Management Systems (SIMS) can collect and represent diverse data but lack sufficient correlation algorithms. By using a Process Query System, we were able to quickly bring together data flowing from many sources, including NIDS, HIDS, server logs, CPU load and memory usage, etc. We constructed PQS models that describe dynamic behavior of complicated attacks and failures, allowing us to detect and differentiate simultaneous sophisticated attacks on a target network. In this paper, we discuss the benefits of implementing such a multistage cyber attack detection system using PQS. We focus on how data from multiple sources can be combined and used to detect and track comprehensive network security events that go unnoticed using conventional tools.

  6. Seeing visual word forms: spatial summation, eccentricity and spatial configuration.

    PubMed

    Kao, Chien-Hui; Chen, Chien-Chung

    2012-06-01

    We investigated observers' performance in detecting and discriminating visual word forms as a function of target size and retinal eccentricity. The contrast threshold of visual words was measured with a spatial two-alternative forced-choice paradigm and a PSI adaptive method. The observers were to indicate which of two sides contained a stimulus in the detection task, and which contained a real character (as opposed to a pseudo- or non-character) in the discrimination task. When the target size was sufficiently small, the detection threshold of a character decreased as its size increased, with a slope of -1/2 on log-log coordinates, up to a critical size at all eccentricities and for all stimulus types. The discrimination threshold decreased with target size with a slope of -1 up to a critical size that was dependent on stimulus type and eccentricity. Beyond that size, the threshold decreased with a slope of -1/2 on log-log coordinates before leveling out. The data was well fit by a spatial summation model that contains local receptive fields (RFs) and a summation across these filters within an attention window. Our result implies that detection is mediated by local RFs smaller than any tested stimuli and thus detection performance is dominated by summation across receptive fields. On the other hand, discrimination is dominated by a summation within a local RF in the fovea but a cross RF summation in the periphery. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Observations from borehole dilution logging experiments in fractured crystalline rock under variable hydraulic conditions

    USGS Publications Warehouse

    Harte, Philip T.; Anderson, Alton; Williams, John H.

    2014-01-01

    Identifying hydraulically active fractures in low permeability, crystalline-bedrock aquifers requires a variety of geophysical and hydrogeophysical borehole tools and approaches. One such approach is Single Borehole Dilution Tests (SBDT), which in some low flow cases have been shown to provide greater resolution of borehole flow than other logging procedures, such as vertical differential Heat Pulse Flowmeter (HPFM) logging. Because the tools used in SBDT collect continuous profiles of water quality or dye changes, they can identify horizontal flow zones and vertical flow. We used SBDT with a food grade blue dye as a tracer and dual photometer-nephelometer measurements to identify low flow zones.SBDT were conducted at seven wells with open boreholes (exceeding 300 ft). At most of the wells HPFM logs were also collected. The seven wells are set in low-permeability, fractured granite and gneiss rocks underlying a former tetrachloroeythylene (PCE) source area at the Savage Municipal Well Superfund site in Milford, NH. Time series SBDT logs were collected at each of the seven wells under three distinct hydraulic conditions: (1) ambient conditions prior to a pump test at an adjacent well, (2) mid test, after 2-3 days of the start of the pump test, and (3) at the end of the test, after 8-9 days of the pump test. None of the SBDT were conducted under pumping conditions in the logged well. For each condition, wells were initially passively spiked with blue dye once and subsequent time series measurements were made.Measurement accuracy and precision of the photometer tool is important in SBDT when attempting to detect low rates of borehole flow. Tests indicate that under ambient conditions, none of the wells had detectable flow as measured with HPFM logging. With SBDT, 4 of the 7 showed the presence of some very low flow. None of 5 (2 of the 7 wells initially logged with HPFM under ambient conditions were not re-logged) wells logged with the HPFM during the pump test had detectable flow. However, 3 of the 5 wells showed the patterns of very low flow with SBDT during the pump test including pumping induced changes of inflow and outflow patterns at one well.

  8. Copy-move forgery detection utilizing Fourier-Mellin transform log-polar features

    NASA Astrophysics Data System (ADS)

    Dixit, Rahul; Naskar, Ruchira

    2018-03-01

    In this work, we address the problem of region duplication or copy-move forgery detection in digital images, along with detection of geometric transforms (rotation and rescale) and postprocessing-based attacks (noise, blur, and brightness adjustment). Detection of region duplication, following conventional techniques, becomes more challenging when an intelligent adversary brings about such additional transforms on the duplicated regions. In this work, we utilize Fourier-Mellin transform with log-polar mapping and a color-based segmentation technique using K-means clustering, which help us to achieve invariance to all the above forms of attacks in copy-move forgery detection of digital images. Our experimental results prove the efficiency of the proposed method and its superiority to the current state of the art.

  9. Comparison of Versant HBV DNA 3.0 and COBAS AmpliPrep-COBAS TaqMan assays for hepatitis B DNA quantitation: Possible clinical implications.

    PubMed

    Garbuglia, A R; Angeletti, C; Lauria, F N; Zaccaro, P; Cocca, A M; Pisciotta, M; Solmone, M; Capobianchi, M R

    2007-12-01

    We compared two commercial assays for HBV DNA quantitation, Versant HBV 3.0, System 340 (bDNA; Bayer Diagnostics) and COBAS AmpliPrep-COBAS TaqMan HBV Test (TaqMan; Roche Diagnostics). Analytical sensitivity, calculated on WHO International Standard, predicted 95% detection rate at 11.4 and 520.2IU/ml for TaqMan and bDNA, respectively. Specificity, established on 50 blood donor samples, was 100% and 84% for TaqMan and bDNA, respectively. When using clinical samples, HBV DNA was detected by TaqMan in 21/55 samples negative to bDNA. Mean values of HBV DNA obtained with bDNA were higher than those obtained with TaqMan (4.09log(10)+/-1.90 versus 3.39log(10)+/-2.41, p<0.001), and 24.4% of samples showed differences in viral load values >0.5log(10), without association with HBV genotype. There was a good correlation for HBV DNA concentrations measured by the two assays (r=0.94; p<0.001) within the overlapping range, and the distribution of results with respect to relevant clinical threshold recently confirmed (20,000 and 2000IU/ml) was similar. Approximately 50% of samples with low HBV DNA, appreciated by TaqMan but not by bDNA, were successfully sequenced in pol region, where drug resistance mutations are located.

  10. Using Unix system auditing for detecting network intrusions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christensen, M.J.

    1993-03-01

    Intrusion Detection Systems (IDSs) are designed to detect actions of individuals who use computer resources without authorization as well as legitimate users who exceed their privileges. This paper describes a novel approach to IDS research, namely a decision aiding approach to intrusion detection. The introduction of a decision tree represents the logical steps necessary to distinguish and identify different types of attacks. This tool, the Intrusion Decision Aiding Tool (IDAT), utilizes IDS-based attack models and standard Unix audit data. Since attacks have certain characteristics and are based on already developed signature attack models, experienced and knowledgeable Unix system administrators knowmore » what to look for in system audit logs to determine if a system has been attacked. Others, however, are usually less able to recognize common signatures of unauthorized access. Users can traverse the tree using available audit data displayed by IDAT and general knowledge they possess to reach a conclusion regarding suspicious activity. IDAT is an easy-to-use window based application that gathers, analyzes, and displays pertinent system data according to Unix attack characteristics. IDAT offers a more practical approach and allows the user to make an informed decision regarding suspicious activity.« less

  11. Reduction of Zika virus infectivity in platelet concentrates after treatment with ultraviolet C light and in plasma after treatment with methylene blue and visible light.

    PubMed

    Fryk, Jesse J; Marks, Denese C; Hobson-Peters, Jody; Watterson, Daniel; Hall, Roy A; Young, Paul R; Reichenberg, Stefan; Tolksdorf, Frank; Sumian, Chryslain; Gravemann, Ute; Seltsam, Axel; Faddy, Helen M

    2017-11-01

    Zika virus (ZIKV) has emerged as a potential threat to transfusion safety worldwide. Pathogen inactivation is one approach to manage this risk. In this study, the efficacy of the THERAFLEX UV-Platelets system and THERAFLEX MB-Plasma system to inactivate ZIKV in platelet concentrates (PCs) and plasma was investigated. PCs spiked with ZIKV were treated with the THERAFLEX UV-Platelets system at 0.05, 0.10, 0.15, and 0.20 J/cm 2 UVC. Plasma spiked with ZIKV was treated with the THERAFLEX MB-Plasma system at 20, 40, 60, and 120 J/cm 2 light at 630 nm with at least 0.8 µmol/L methylene blue (MB). Samples were taken before the first and after each illumination dose and tested for residual virus. For each system the level of viral reduction was determined. Treatment of PCs with THERAFLEX UV-Platelets system resulted in a mean of 5 log reduction in ZIKV infectivity at the standard UVC dose (0.20 J/cm 2 ), with dose dependency observed with increasing UVC dose. For plasma treated with MB and visible light, ZIKV infectivity was reduced by a mean of at least 5.68 log, with residual viral infectivity reaching the detection limit of the assay at 40 J/cm 2 (one-third the standard dose). Our study demonstrates that the THERAFLEX UV-Platelets system and THERAFLEX MB-Plasma system can reduce ZIKV infectivity in PCs and pooled plasma to the detection limit of the assays used. These findings suggest both systems have the capacity to be an effective option to manage potential ZIKV transfusion transmission risk. © 2017 AABB.

  12. Balloon logging with the inverted skyline

    NASA Technical Reports Server (NTRS)

    Mosher, C. F.

    1975-01-01

    There is a gap in aerial logging techniques that has to be filled. The need for a simple, safe, sizeable system has to be developed before aerial logging will become effective and accepted in the logging industry. This paper presents such a system designed on simple principles with realistic cost and ecological benefits.

  13. New protocol for αAstree electronic tongue enabling full performance qualification according to ICH Q2.

    PubMed

    Pein, Miriam; Eckert, Carolin; Preis, Maren; Breitkreutz, Jörg

    2013-09-01

    Performance qualification (PQ) of taste sensing systems is mandatory for their use in pharmaceutical industry. According to ICH Q2 (R1) and a recent adaptation for taste sensing systems, non-specificity, log-linear relationships between the concentration of analytes and the sensor signal as well as a repeatability with relative standard deviation (RSD) values <4% were defined as basic requirements to pass a PQ. In the present work, the αAstree taste sensing system led to a successful PQ procedure by the use of recent sensor batches for pharmaceutical applications (sensor set #2) and a modified measurement protocol. Log-linear relationships between concentration and responses of each sensor were investigated for different bitter tasting active pharmaceutical ingredients (APIs). Using the new protocol, RSD values <2.1% were obtained in the repeatability study. Applying the visual evaluation approach, detection and quantitation limit could be determined for caffeine citrate with every sensor (LOD 0.05-0.5 mM, LOQ: 0.1-0.5 mM). In addition, the sensor set marketed for food applications (sensor set #5) was proven to show beneficial effects regarding the log-linear relationship between the concentration of quinine hydrochloride and the sensor signal. By the use of our proposed protocol, it is possible to implement the αAstree taste sensing system as a tool to assure quality control in the pharmaceutical industry. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. REAL-TIME TRACER MONITORING OF RESERVOIR STIMULATION PROCEDURES VIA ELECTRONIC WIRELINE AND TELEMETRY DATA TRANSMISSION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George L. Scott III

    2005-01-01

    Finalized Phase 2-3 project work has field-proven two separate real-time reservoir processes that were co-developed via funding by the National Energy Technology Laboratory (NETL). Both technologies are presently patented in the United States and select foreign markets; a downhole-commingled reservoir stimulation procedure and a real-time tracer-logged fracturing diagnostic system. Phase 2 and early Phase 3 project work included the research, development and well testing of a U.S. patented gamma tracer fracturing diagnostic system. This stimulation logging process was successfully field-demonstrated; real-time tracer measurement of fracture height while fracturing was accomplished and proven technically possible. However, after the initial well tests,more » there were several licensing issues that developed between service providers that restricted and minimized Realtimezone's (RTZ) ability to field-test the real-time gamma diagnostic system as was originally outlined for this project. Said restrictions were encountered after when one major provider agreed to license their gamma logging tools to another. Both of these companies previously promised contributory support toward Realtimezone's DE-FC26-99FT40129 project work, however, actual support was less than desired when newly-licensed wireline gamma logging tools from one company were converted by the other from electric wireline into slickline, batter-powered ''memory'' tools for post-stimulation logging purposes. Unfortunately, the converted post-fracture measurement memory tools have no applications in experimentally monitoring real-time movement of tracers in the reservoir concurrent with the fracturing treatment. RTZ subsequently worked with other tracer gamma-logging tool companies for basic gamma logging services, but with lessened results due to lack of multiple-isotope detection capability. In addition to real-time logging system development and well testing, final Phase 2 and Phase 3 project work included the development of a real-time reservoir stimulation procedure, which was successfully field-demonstrated and is presently patented in the U.S. and select foreign countries, including Venezuela, Brazil and Canada. Said patents are co-owned by RTZ and the National Energy Technology Lab (NETL). In 2002, Realtimezone and the NETL licensed said patents to Halliburton Energy Services (HES). Additional licensing agreements (LA) are anticipated with other service industry companies in 2005. Final Phase 3 work has led to commercial applications of the real-time reservoir stimulation procedure. Four successfully downhole-mixed well tests were conducted with commercially expected production results. The most recent, fourth field test was a downhole-mixed stimulated well completed in June, 2004, which currently produces 11 BOPD with 90 barrels of water per day. Conducted Phase 2 and Phase 3 field-test work to date has resulted in the fine-tuning of a real-time enhanced stimulation system that will significantly increase future petroleum well recoveries in the United States and foreign petroleum fields, both onshore and offshore, and in vertical and horizontal wells.« less

  15. Brine delineation and monitoring with electrical resistivity tomography and electromagnetic borehole logging at the Fort Knox well field near West Point, Kentucky

    USGS Publications Warehouse

    Henderson, Rory; Unthank, Michael D.; Zettwoch, Douglas D.; Lane, John W.

    2010-01-01

    The potable water system at Fort Knox is threatened by brine contamination from improperly abandoned natural gas exploration wells. The Fort Knox well field is located near the town of West Point, Kentucky, in the flood plain of the Ohio River. At the site, unconsolidated sediments approximately 30 – 40 m thick, overlie shale and porous limestone. Brine is believed to flow vertically from the underlying formations to the unconsolidated aquifer through damaged or leaky well casings under a high hydraulic gradient from the artificially pressurized porous limestone, which is utilized for natural gas storage by a regional energy company. Upon reaching the unconsolidated aquifer, brinecontaminated groundwater enters water supply production wells under the pumping‐induced gradient. As part of the Fort Knox remediation strategy to reduce the impact of brine contamination, electrical resistivity tomography (ERT) and borehole electromagnetic (EM) logs are being collected annually to detect gross changes in subsurface conductivity. The 2009 ERT data show areas of high conductivity on the western (contaminated) side of the site with conductivities more than an order of magnitude higher than on the eastern (uncontaminated) side of the site. The areas of high conductivity are interpreted as brine contamination, consistent with known regions of brine contamination. Conductivities from the EM logs are consistent with the results from the ERT inversions. The EM logs show little change between 2008 and 2009, except for some small changes in the brine distribution in well PZ1. Yearly ERT surveys will be continued to detect new areas of brine contamination and monitor the remediation effort.

  16. Damped and sub-damped Lyman-α absorbers in z > 4 QSOs

    NASA Astrophysics Data System (ADS)

    Guimarães, R.; Petitjean, P.; de Carvalho, R. R.; Djorgovski, S. G.; Noterdaeme, P.; Castro, S.; Poppe, P. C. Da R.; Aghaee, A.

    2009-12-01

    We present the results of a survey of damped (DLA, log~N(H i)>20.3) and sub-damped Lyman-α systems (19.5 2.55 along the lines-of-sight to 77 quasars with emission redshifts in the range 419.5 were detected of which 40 systems are damped Lyman-α systems for an absorption length of Δ X = 378. About half of the lines of sight of this homogeneous survey have never been investigated for DLAs. We study the evolution with redshift of the cosmological density of the neutral gas and find, consistent with previous studies at similar resolution, that ΩDLA, H_I decreases at z>3.5. The overall cosmological evolution of Ω_HI shows a peak around this redshift. The H i column density distribution for log N(H i)≥20.3 is fitted, consistent with previous surveys, with a single power-law of index α ˜ -1.8 ±0.25. This power-law overpredicts data at the high-end and a second, much steeper, power-law (or a gamma function) is needed. There is a flattening of the function at lower H i column densities with an index of α ˜ -1.4 for the column density range log N(H i)=19.5-21. The fraction of H i mass in sub-DLAs is of the order of 30%. The H i column density distribution does not evolve strongly from z˜ 2.5 to z˜ 4.5. The observations reported here were obtained with the W. M. Keck Observatory, which is operated by the California Association for Research in Astronomy, a scientific partnership among the California Institute of Technology, the University of California, and the National Aeronautics and Space Administration. Tables 1, 2 and Appendices are only available in electronic form at http://www.aanda.org

  17. NMR Methods, Applications and Trends for Groundwater Evaluation and Management

    NASA Astrophysics Data System (ADS)

    Walsh, D. O.; Grunewald, E. D.

    2011-12-01

    Nuclear magnetic resonance (NMR) measurements have a tremendous potential for improving groundwater characterization, as they provide direct detection and measurement of groundwater and unique information about pore-scale properties. NMR measurements, commonly used in chemistry and medicine, are utilized in geophysical investigations through non-invasive surface NMR (SNMR) or downhole NMR logging measurements. Our recent and ongoing research has focused on improving the performance and interpretation of NMR field measurements for groundwater characterization. Engineering advancements have addressed several key technical challenges associated with SNMR measurements. Susceptibility of SNMR measurements to environmental noise has been dramatically reduced through the development of multi-channel acquisition hardware and noise-cancellation software. Multi-channel instrumentation (up to 12 channels) has also enabled more efficient 2D and 3D imaging. Previous limitations in measuring NMR signals from water in silt, clay and magnetic geology have been addressed by shortening the instrument dead-time from 40 ms to 4 ms, and increasing the power output. Improved pulse sequences have been developed to more accurately estimate NMR relaxation times and their distributions, which are sensitive to pore size distributions. Cumulatively, these advancements have vastly expanded the range of environments in which SNMR measurements can be obtained, enabling detection of groundwater in smaller pores, in magnetic geology, in the unsaturated zone, and nearby to infrastructure (presented here in case studies). NMR logging can provide high-resolution estimates of bound and mobile water content and pore size distributions. While NMR logging has been utilized in oil and gas applications for decades, its use in groundwater investigations has been limited by the large size and high cost of oilfield NMR logging tools and services. Recently, engineering efforts funded by the US Department of Energy have produced an NMR logging tool that is much smaller and less costly than comparable oilfield NMR logging tools. This system is specifically designed for near surface groundwater investigations, incorporates small diameter probes (as small as 1.67 inches diameter) and man-portable surface stations, and provides NMR data and information content on par with oilfield NMR logging tools. A direct-push variant of this logging tool has also been developed. Key challenges associated with small diameter tools include inherently lower SNR and logging speeds, the desire to extend the sensitive zone as far as possible into unconsolidated formations, and simultaneously maintaining high power and signal fidelity. Our ongoing research in groundwater NMR aims to integrating surface and borehole measurements for regional-scale permeability mapping, and to develop in-place NMR sensors for long term monitoring of contaminant and remediation processes. In addition to groundwater resource characterization, promising new applications of NMR include assessing water content in ice and permafrost, management of groundwater in mining operations, and evaluation and management of groundwater in civil engineering applications.

  18. Parental perceptions of the learner driver log book system in two Australian states.

    PubMed

    Bates, Lyndel; Watson, Barry; King, Mark Johann

    2014-01-01

    Though many jurisdictions internationally now require learner drivers to complete a specified number of hours of supervised driving practice before being able to drive unaccompanied, very few require learner drivers to complete a log book to record this practice and then present it to the licensing authority. Learner drivers in most Australian jurisdictions must complete a log book that records their practice, thereby confirming to the licensing authority that they have met the mandated hours of practice requirement. These log books facilitate the management and enforcement of minimum supervised hours of driving requirements. Parents of learner drivers in 2 Australian states, Queensland and New South Wales, completed an online survey assessing a range of factors, including their perceptions of the accuracy of their child's learner log book and the effectiveness of the log book system. The study indicates that the large majority of parents believe that their child's learner log book is accurate. However, they generally report that the log book system is only moderately effective as a system to measure the number of hours of supervised practice a learner driver has completed. The results of this study suggest the presence of a paradox, with many parents possibly believing that others are not as diligent in the use of log books as they are or that the system is too open to misuse. Given that many parents report that their child's log book is accurate, this study has important implications for the development and ongoing monitoring of hours of practice requirements in graduated driver licensing systems.

  19. Multicenter evaluation of a commercial multiplex polymerase chain reaction test for screening plasma donations for parvovirus B19 DNA and hepatitis A virus RNA.

    PubMed

    Koppelman, Marco H G M; Cuijpers, H Theo M; Wessberg, Susanna; Valkeajärvi, Anne; Pichl, Lutz; Schottstedt, Volkmar; Saldanha, John

    2012-07-01

    Three European laboratories evaluated the TaqScreen DPX test (DPX test), a multiplex nucleic acid test assay for the simultaneous detection and quantitation of parvovirus B19 (B19V) DNA and the detection of hepatitis A virus (HAV) RNA. The 95% limit of detection of the test for B19V and HAV was determined using the respective WHO International Standards. The reproducibility of the test was evaluated by testing replicate samples of B19V at log 4.0 and 40 IU/mL and HAV at 5 IU/mL. The accuracy of the DPX test for B19V was evaluated by replicate testing of B19V samples containing log 3.0, log 4.0, and log 5.0 IU/mL. Panels of B19V Genotypes 1, 2, and 3 and HAV genotypes were evaluated. Cross-contamination was evaluated. For comparison of the DPX test and the established tests, the sites tested plasma samples in pools of either 96 or 480 donations. The mean 95% lower limits of detection of the three laboratories for B19V and HAV were 20.30 and 1.85 IU/mL. The test showed good reproducibility with the major part of the variance of the test being attributed to intermediate assay variation. The test showed great accuracy for B19V, especially at log 4.0 IU/mL. Spiking of test pools of 480 donations and manufacturing pools with log 4.0 IU/mL B19 DNA and 4 IU/mL HAV RNA showed that the DPX assay was robust. The test was able to detect the three genotypes of B19V and HAV genotypes. No cross-contamination was seen. Test results of routine samples correlated well with those of the established tests. The DPX test is a robust and sensitive test for the detection of B19V and HAV in plasma samples. The quantitative B19V results obtained with the test are accurate, and the test is able to detect all the known genotypes of B19V and HAV and fulfills all the European Pharmacopoeia and Food and Drug Administration requirements for a B19V and HAV test for screening of plasma donations and samples from plasma pools for manufacture. © 2012 American Association of Blood Banks.

  20. Extracting the Textual and Temporal Structure of Supercomputing Logs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jain, S; Singh, I; Chandra, A

    2009-05-26

    Supercomputers are prone to frequent faults that adversely affect their performance, reliability and functionality. System logs collected on these systems are a valuable resource of information about their operational status and health. However, their massive size, complexity, and lack of standard format makes it difficult to automatically extract information that can be used to improve system management. In this work we propose a novel method to succinctly represent the contents of supercomputing logs, by using textual clustering to automatically find the syntactic structures of log messages. This information is used to automatically classify messages into semantic groups via an onlinemore » clustering algorithm. Further, we describe a methodology for using the temporal proximity between groups of log messages to identify correlated events in the system. We apply our proposed methods to two large, publicly available supercomputing logs and show that our technique features nearly perfect accuracy for online log-classification and extracts meaningful structural and temporal message patterns that can be used to improve the accuracy of other log analysis techniques.« less

  1. Linearly Supporting Feature Extraction for Automated Estimation of Stellar Atmospheric Parameters

    NASA Astrophysics Data System (ADS)

    Li, Xiangru; Lu, Yu; Comte, Georges; Luo, Ali; Zhao, Yongheng; Wang, Yongjun

    2015-05-01

    We describe a scheme to extract linearly supporting (LSU) features from stellar spectra to automatically estimate the atmospheric parameters {{T}{\\tt{eff} }}, log g, and [Fe/H]. “Linearly supporting” means that the atmospheric parameters can be accurately estimated from the extracted features through a linear model. The successive steps of the process are as follow: first, decompose the spectrum using a wavelet packet (WP) and represent it by the derived decomposition coefficients; second, detect representative spectral features from the decomposition coefficients using the proposed method Least Absolute Shrinkage and Selection Operator (LARS)bs; third, estimate the atmospheric parameters {{T}{\\tt{eff} }}, log g, and [Fe/H] from the detected features using a linear regression method. One prominent characteristic of this scheme is its ability to evaluate quantitatively the contribution of each detected feature to the atmospheric parameter estimate and also to trace back the physical significance of that feature. This work also shows that the usefulness of a component depends on both the wavelength and frequency. The proposed scheme has been evaluated on both real spectra from the Sloan Digital Sky Survey (SDSS)/SEGUE and synthetic spectra calculated from Kurucz's NEWODF models. On real spectra, we extracted 23 features to estimate {{T}{\\tt{eff} }}, 62 features for log g, and 68 features for [Fe/H]. Test consistencies between our estimates and those provided by the Spectroscopic Parameter Pipeline of SDSS show that the mean absolute errors (MAEs) are 0.0062 dex for log {{T}{\\tt{eff} }} (83 K for {{T}{\\tt{eff} }}), 0.2345 dex for log g, and 0.1564 dex for [Fe/H]. For the synthetic spectra, the MAE test accuracies are 0.0022 dex for log {{T}{\\tt{eff} }} (32 K for {{T}{\\tt{eff} }}), 0.0337 dex for log g, and 0.0268 dex for [Fe/H].

  2. Lithology identification of aquifers from geophysical well logs and fuzzy logic analysis: Shui-Lin Area, Taiwan

    NASA Astrophysics Data System (ADS)

    Hsieh, Bieng-Zih; Lewis, Charles; Lin, Zsay-Shing

    2005-04-01

    The purpose of this study is to construct a fuzzy lithology system from well logs to identify formation lithology of a groundwater aquifer system in order to better apply conventional well logging interpretation in hydro-geologic studies because well log responses of aquifers are sometimes different from those of conventional oil and gas reservoirs. The input variables for this system are the gamma-ray log reading, the separation between the spherically focused resistivity and the deep very-enhanced resistivity curves, and the borehole compensated sonic log reading. The output variable is groundwater formation lithology. All linguistic variables are based on five linguistic terms with a trapezoidal membership function. In this study, 50 data sets are clustered into 40 training sets and 10 testing sets for constructing the fuzzy lithology system and validating the ability of system prediction, respectively. The rule-based database containing 12 fuzzy lithology rules is developed from the training data sets, and the rule strength is weighted. A Madani inference system and the bisector of area defuzzification method are used for fuzzy inference and defuzzification. The success of training performance and the prediction ability were both 90%, with the calculated correlation of training and testing equal to 0.925 and 0.928, respectively. Well logs and core data from a clastic aquifer (depths 100-198 m) in the Shui-Lin area of west-central Taiwan are used for testing the system's construction. Comparison of results from core analysis, well logging and the fuzzy lithology system indicates that even though the well logging method can easily define a permeable sand formation, distinguishing between silts and sands and determining grain size variation in sands is more subjective. These shortcomings can be improved by a fuzzy lithology system that is able to yield more objective decisions than some conventional methods of log interpretation.

  3. Composition and Temperature Dependence of Shear Viscosity of Hydrocarbon Mixtures

    DTIC Science & Technology

    1980-07-01

    HNN- XTHDCPD Binary System IX. VTF Eq. Parameters for Shear Viscosities Using Constant B Parameter X. Results of Fits to Master Viscosity Eqs. (43...T(K) for 5 C10 Hydrocarbons I Fig. 2a. log n versus 103/T(K) for HNNi I Fig. 2b. log n versus 103/T(K) for XTHDCPD Fig. 3. Isothem of log n versus X...CD for CO-MO Binary System Fig. 4. Isotherm of log n versus XNBC for NBC-DMO Binary System ( ~Fig. 5. Isotherm of log n versus XfINN for HNN- XTHDCPD

  4. 6. Log calving barn. Interior view showing log postandbeam support ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Log calving barn. Interior view showing log post-and-beam support system and animal stalls. - William & Lucina Bowe Ranch, Log Calving Barn, 230 feet south-southwest of House, Melrose, Silver Bow County, MT

  5. CO-dark molecular gas at high redshift: very large H2 content and high pressure in a low-metallicity damped Lyman alpha system

    NASA Astrophysics Data System (ADS)

    Balashev, S. A.; Noterdaeme, P.; Rahmani, H.; Klimenko, V. V.; Ledoux, C.; Petitjean, P.; Srianand, R.; Ivanchik, A. V.; Varshalovich, D. A.

    2017-09-01

    We present a detailed analysis of an H2-rich, extremely strong intervening damped Ly α absorption system (DLA) at zabs = 2.786 towards the quasar J 0843+0221, observed with the Ultraviolet and Visual Echelle Spectrograph on the Very Large Telescope. The total column density of molecular (resp. atomic) hydrogen is log N(H2) = 21.21 ± 0.02 (resp. log N(H I) = 21.82 ± 0.11), making it to be the first case in quasar absorption line studies with H2 column density as high as what is seen in 13CO-selected clouds in the Milky Way. We find that this system has one of the lowest metallicity detected among H2-bearing DLAs, with [Zn/H] = -1.52^{+0.08}_{-0.10}. This can be the reason for the marked differences compared to systems with similar H2 column densities in the local Universe: (I) the kinetic temperature, T ˜ 120 K, derived from the J = 0, 1 H2 rotational levels is at least twice higher than expected; (II) there is little dust extinction with AV < 0.1; (III) no CO molecules are detected, putting a constraint on the XCO factor XCO > 2 × 1023 cm-2/(km s-1 K), in the very low metallicity gas. Low CO and high H2 contents indicate that this system represents 'CO-dark/faint' gas. We investigate the physical conditions in the H2-bearing gas using the fine-structure levels of C I, C II, Si II and the rotational levels of HD and H2. We find the number density to be about n ˜ 260-380 cm-3, implying a high thermal pressure of 3-5 × 104 cm-3 K. We further identify a trend of increasing pressure with increasing total hydrogen column density. This independently supports the suggestion that extremely strong DLAs (with log N(H) ˜22) probe high-z galaxies at low impact parameters.

  6. CLARET user's manual: Mainframe Logs. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frobose, R.H.

    1984-11-12

    CLARET (Computer Logging and RETrieval) is a stand-alone PDP 11/23 system that can support 16 terminals. It provides a forms-oriented front end by which operators enter online activity logs for the Lawrence Livermore National Laboratory's OCTOPUS computer network. The logs are stored on the PDP 11/23 disks for later retrieval, and hardcopy reports are generated both automatically and upon request. Online viewing of the current logs is provided to management. As each day's logs are completed, the information is automatically sent to a CRAY and included in an online database system. The terminal used for the CLARET system is amore » dual-port Hewlett Packard 2626 terminal that can be used as either the CLARET logging station or as an independent OCTOPUS terminal. Because this is a stand-alone system, it does not depend on the availability of the OCTOPUS network to run and, in the event of a power failure, can be brought up independently.« less

  7. Effects of Methamphetamine on Vigilance and Tracking during Extended Wakefulness.

    DTIC Science & Technology

    1993-09-01

    the log likelihood ratio (log(p); Green & Swets, 1966; Macmillan & Creelman , 1990), was also derived from hit and false-alarm probabilities...vigilance task. Canadian Journal of Psychology, 19, 104-110. Macmillan, N.E., & Creelman , C.D. (1990). Response bias: Characteristics of detection

  8. A three-dimensional optimal sawing system for small sawmills in central Appalachia

    Treesearch

    Wenshu Lin; Jingxin Wang; R. Edward. Thomas

    2011-01-01

    A three-dimensional (3D) log sawing optimization system was developed to perform 3D log generation, opening face determination, sawing simulation, and lumber grading. Superficial characteristics of logs such as length, large-end and small-end diameters, and external defects were collected from local sawmills. Internal log defect positions and shapes were predicted...

  9. Challenges in converting among log scaling methods.

    Treesearch

    Henry Spelter

    2003-01-01

    The traditional method of measuring log volume in North America is the board foot log scale, which uses simple assumptions about how much of a log's volume is recoverable. This underestimates the true recovery potential and leads to difficulties in comparing volumes measured with the traditional board foot system and those measured with the cubic scaling systems...

  10. Sonic logging for detecting the excavation disturbed and fracture zones

    NASA Astrophysics Data System (ADS)

    Lin, Y. C.; Chang, Y. F.; Liu, J. W.; Tseng, C. W.

    2017-12-01

    This study presents a new sonic logging method to detect the excavation disturbed zone (EDZ) and fracture zones in a tunnel. The EDZ is a weak rock zone where its properties and conditions have been changed by excavation, which results such as fracturing, stress redistribution and desaturation in this zone. Thus, the EDZ is considered as a physically less stable and could form a continuous and high-permeable pathway for groundwater flow. Since EDZ and fracture zone have the potential of affecting the safety of the underground openings and repository performance, many studies were conducted to characterize the EDZ and fracture zone by different methods, such as the rock mass displacements and strain measurements, seismic refraction survey, seismic tomography and hydraulic test, etc. In this study, we designed a new sonic logging method to explore the EDZ and fracture zone in a tunnel at eastern Taiwan. A high power and high frequency sonic system was set up which includes a two hydrophones pitch-catch technique with a common-offset immersed in water-filled uncased wells and producing a 20 KHz sound to scan the well rock. Four dominant sonic events were observed in the measurements, they are refracted P- and S-wave along the well rock, direct water wave and the reverberation in the well water. Thus the measured P- and S-wave velocities, the signal-to-noise ratio of the refraction and the amplitudes of reverberation along the well rock were used as indexes to determine the EDZ and fracture zone. Comparing these indexes with core samples shows that significant changes in the indexes are consistent with the EDZ and fracture zone. Thus, the EDZ and fracture zone can be detected by this new sonic method conclusively.

  11. Fabrication of SrTiO3 Layer on Pt Electrode for Label-Free Capacitive Biosensors

    PubMed Central

    Carapella, Giovanni; Pilloton, Roberto; Di Matteo, Marisa

    2018-01-01

    Due to their interesting ferroelectric, conductive and dielectric properties, in recent years, perovskite-structured materials have begun to attract increasing interest in the biosensing field. In this study, a strontium titanate perovskite layer (SrTiO3) has been synthesized on a platinum electrode and exploited for the development of an impedimetric label-free immunosensor for Escherichia coli O157:H7 detection. The electrochemical characterization of the perovskite-modified electrode during the construction of the immunosensor, as well as after the interaction with different E. coli O157:H7 concentrations, showed a reproducible decrease of the total capacitance of the system that was used for the analytical characterization of the immunosensor. Under optimized conditions, the capacitive immunosensor showed a linear relationship from to 1 to 7 log cfu/mL with a low detection limit of 1 log cfu/mL. Moreover, the atomic force microscopy (AFM) technique underlined the increase in roughness of the SrTiO3-modified electrode surface after antibody immobilization, as well as the effective presence of cells with the typical size of E. coli. PMID:29547521

  12. DIY Soundcard Based Temperature Logging System. Part II: Applications

    ERIC Educational Resources Information Center

    Nunn, John

    2016-01-01

    This paper demonstrates some simple applications of how temperature logging systems may be used to monitor simple heat experiments, and how the data obtained can be analysed to get some additional insight into the physical processes. [For "DIY Soundcard Based Temperature Logging System. Part I: Design," see EJ1114124.

  13. Detection of emission lines from z ˜ 3 DLAs towards the QSO J2358+0149

    NASA Astrophysics Data System (ADS)

    Srianand, Raghunathan; Hussain, Tanvir; Noterdaeme, Pasquier; Petitjean, Patrick; Krühler, Thomas; Japelj, Jure; Pâris, Isabelle; Kashikawa, Nobunari

    2016-07-01

    Using VLT/X-shooter, we searched for emission line galaxies associated with four damped Lyman α systems (DLAs) and one sub-DLA at 2.73 ≤z ≤3.25 towards QSO J2358+0149. We detect [O III] emission from a `low-cool' DLA at zabs = 2.9791 (having log N(H I) = 21.69 ± 0.10, [Zn/H] = -1.83 ± 0.18) at an impact parameter of, ρ ˜ 12 kpc. The associated galaxy is compact with a dynamical mass of (1-6) × 109 M⊙, very high excitation ([O III]/[O II] and [O III]/[Hβ] both greater than 10), 12+[O/H]≤8.5 and moderate star formation rate (SFR ≤2 M⊙ yr-1). Such properties are typically seen in the low-z extreme blue compact dwarf galaxies. The kinematics of the gas is inconsistent with that of an extended disc and the gas is part of either a large scale wind or cold accretion. We detect Lyα emission from the zabs = 3.2477 DLA [having log N(H I) = 21.12 ± 0.10 and [Zn/H] = -0.97 ± 0.13]. The Lyα emission is redshifted with respect to the metal absorption lines by 320 km s-1, consistent with the location of the red hump expected in radiative transport models. We derive SFR ˜0.2-1.7 M⊙ yr-1 and Lyα escape fraction of ≥10 per cent. No other emission line is detected from this system. Because the DLA has a small velocity separation from the quasar (˜500 km s-1) and the DLA emission is located within a small projected distance (ρ < 5 kpc), we also explore the possibility that the Lyα emission is being induced by the QSO itself. QSO-induced Lyα fluorescence is possible if the DLA is within a physical separation of 340 kpc to the QSO. Detection of stellar continuum light and/or the oxygen emission lines would disfavour this possibility. We do not detect any emission line from the remaining three systems.

  14. Job monitoring on DIRAC for Belle II distributed computing

    NASA Astrophysics Data System (ADS)

    Kato, Yuji; Hayasaka, Kiyoshi; Hara, Takanori; Miyake, Hideki; Ueda, Ikuo

    2015-12-01

    We developed a monitoring system for Belle II distributed computing, which consists of active and passive methods. In this paper we describe the passive monitoring system, where information stored in the DIRAC database is processed and visualized. We divide the DIRAC workload management flow into steps and store characteristic variables which indicate issues. These variables are chosen carefully based on our experiences, then visualized. As a result, we are able to effectively detect issues. Finally, we discuss the future development for automating log analysis, notification of issues, and disabling problematic sites.

  15. Managing vulnerabilities and achieving compliance for Oracle databases in a modern ERP environment

    NASA Astrophysics Data System (ADS)

    Hölzner, Stefan; Kästle, Jan

    In this paper we summarize good practices on how to achieve compliance for an Oracle database in combination with an ERP system. We use an integrated approach to cover both the management of vulnerabilities (preventive measures) and the use of logging and auditing features (detective controls). This concise overview focusses on the combination Oracle and SAP and it’s dependencies, but also outlines security issues that arise with other ERP systems. Using practical examples, we demonstrate common vulnerabilities and coutermeasures as well as guidelines for the use of auditing features.

  16. Development of a low cost unmanned aircraft system for atmospheric carbon dioxide leak detection

    NASA Astrophysics Data System (ADS)

    Mitchell, Taylor Austin

    Carbon sequestration, the storage of carbon dioxide gas underground, has the potential to reduce global warming by removing a greenhouse gas from the atmosphere. These storage sites, however, must first be monitored to detect if carbon dioxide is leaking back out to the atmosphere. As an alternative to traditional large ground-based sensor networks to monitor CO2 levels for leaks, unmanned aircraft offer the potential to perform in-situ atmospheric leak detection over large areas for a fraction of the cost. This project developed a proof-of-concept sensor system to map relative carbon dioxide levels to detect potential leaks. The sensor system included a Sensair K-30 FR CO2 sensor, GPS, and altimeter connected an Arduino microcontroller which logged data to an onboard SD card. Ground tests were performed to verify and calibrate the system including wind tunnel tests to determine the optimal configuration of the system for the quickest response time (4-8 seconds based upon flowrate). Tests were then conducted over a controlled release of CO 2 in addition to over controlled rangeland fires which released carbon dioxide over a large area as would be expected from a carbon sequestration source. 3D maps of carbon dioxide were developed from the system telemetry that clearly illustrated increased CO2 levels from the fires. These tests demonstrated the system's ability to detect increased carbon dioxide concentrations in the atmosphere.

  17. Well logging evaporative thermal protection system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamers, M.D.; Martelli, V.P.

    1981-02-03

    An evaporative thermal protection system for use in hostile environment well logging applications, the system including a downhole thermal protection cartridge disposed within a well logging sonde or tool to keep a payload such as sensors and support electronics cool, the cartridge carrying either an active evaporative system for refrigeration or a passive evaporative system, both exhausting to the surface through an armored flexible fluidic communication mechanical cable.

  18. myBlackBox: Blackbox Mobile Cloud Systems for Personalized Unusual Event Detection.

    PubMed

    Ahn, Junho; Han, Richard

    2016-05-23

    We demonstrate the feasibility of constructing a novel and practical real-world mobile cloud system, called myBlackBox, that efficiently fuses multimodal smartphone sensor data to identify and log unusual personal events in mobile users' daily lives. The system incorporates a hybrid architectural design that combines unsupervised classification of audio, accelerometer and location data with supervised joint fusion classification to achieve high accuracy, customization, convenience and scalability. We show the feasibility of myBlackBox by implementing and evaluating this end-to-end system that combines Android smartphones with cloud servers, deployed for 15 users over a one-month period.

  19. myBlackBox: Blackbox Mobile Cloud Systems for Personalized Unusual Event Detection

    PubMed Central

    Ahn, Junho; Han, Richard

    2016-01-01

    We demonstrate the feasibility of constructing a novel and practical real-world mobile cloud system, called myBlackBox, that efficiently fuses multimodal smartphone sensor data to identify and log unusual personal events in mobile users’ daily lives. The system incorporates a hybrid architectural design that combines unsupervised classification of audio, accelerometer and location data with supervised joint fusion classification to achieve high accuracy, customization, convenience and scalability. We show the feasibility of myBlackBox by implementing and evaluating this end-to-end system that combines Android smartphones with cloud servers, deployed for 15 users over a one-month period. PMID:27223292

  20. Sample Introduction Using the Hildebrand Grid Nebulizer for Plasma Spectrometry

    DTIC Science & Technology

    1988-01-01

    linear dynamic ranges, precision, and peak width were de- termined for elements in methanol and acetonitrile solutions. , (1)> The grid nebulizer was...FIA) with ICP-OES detection were evaluated. Detec- tion limits, linear dynamic ranges, precision, and peak width were de- termined for elements in...Concentration vs. Log Peak Area for Mn, 59 Cd, Zn, Au, Ni in Methanol (CMSC) 3-28 Log Concentration vs. Log Peak Area for Mn, 60 Cd, Au, Ni in

  1. Geophysical examination of coal deposits

    NASA Astrophysics Data System (ADS)

    Jackson, L. J.

    1981-04-01

    Geophysical techniques for the solution of mining problems and as an aid to mine planning are reviewed. Techniques of geophysical borehole logging are discussed. The responses of the coal seams to logging tools are easily recognized on the logging records. Cores for laboratory analysis are cut from selected sections of the borehole. In addition, information about the density and chemical composition of the coal may be obtained. Surface seismic reflection surveys using two dimensional arrays of seismic sources and detectors detect faults with throws as small as 3 m depths of 800 m. In geologically disturbed areas, good results have been obtained from three dimensional surveys. Smaller faults as far as 500 m in advance of the working face may be detected using in seam seismic surveying conducted from a roadway or working face. Small disturbances are detected by pulse radar and continuous wave electromagnetic methods either from within boreholes or from underground. Other geophysical techniques which explicit the electrical, magnetic, gravitational, and geothermal properties of rocks are described.

  2. Development of a 3D log sawing optimization system for small sawmills in central Appalachia, US

    Treesearch

    Wenshu Lin; Jingxin Wang; Edward Thomas

    2011-01-01

    A 3D log sawing optimization system was developed to perform log generation, opening face determination, sawing simulation, and lumber grading using 3D modeling techniques. Heuristic and dynamic programming algorithms were used to determine opening face and grade sawing optimization. Positions and shapes of internal log defects were predicted using a model developed by...

  3. A modification of the fusion model for log polar coordinates

    NASA Technical Reports Server (NTRS)

    Griswold, N. C.; Weiman, Carl F. R.

    1990-01-01

    The fusion mechanism for application in stereo analysis of range restricted the depth of field and therefore required a shift variant mechanism in the peripheral area to find disparity. Misregistration was prevented by restricting the disparity detection range to a neighborhood spanned by the directional edge detection filters. This transformation was essentially accomplished by a nonuniform resampling of the original image in a horizontal direction. While this is easily implemented for digital processing, the approach does not (in the peripheral vision area) model the log-conformal mapping which is known to occur in the human mechanism. This paper therefore modifies the original fusion concept in the peripheral area to include the polar exponential grid-to-log conformal tesselation. Examples of the fusion process resulting in accurate disparity values are given.

  4. Performance of the cobas Hepatitis B virus (HBV) test using the cobas 4800 system and comparison of HBV DNA quantification ability between the COBAS AmpliPrep/COBAS TaqMan HBV test version 2.0 and cobas HBV test.

    PubMed

    Shin, Kyung-Hwa; Lee, Hyun-Ji; Chang, Chulhun L; Kim, Hyung-Hoi

    2018-04-01

    Hepatitis B virus (HBV) DNA levels are used to predict the response to therapy, determine therapy initiation, monitor resistance to therapy, and establish treatment success. To verify the performance of the cobas HBV test using the cobas 4800 system for HBV DNA quantification and to compare the HBV DNA quantification ability between the cobas HBV test and COBAS AmpliPrep/COBAS TaqMan HBV version 2.0 (CAP/CTM v2.0). The precision, linearity, and limit of detection of the cobas HBV test were evaluated using the 4th World Health Organization International Standard material and plasma samples. Clinical samples that yielded quantitative results using the CAP/CTM v2.0 and cobas HBV tests were subjected to correlational analysis. Three hundred forty-nine samples were subjected to correlational analysis, among which 114 samples showed results above the lower limit of quantification. Comparable results were obtained ([cobas HBV test] = 1.038 × [CAP/CTM v2.0]-0.173, r = 0.914) in 114 samples, which yielded values above the lower limit of quantification. The results for 86.8% of the samples obtained using the cobas HBV test were within 0.5 log 10 IU/mL of the CAP/CTM v2.0 results. The total precision values against the low and high positive controls were 1.4% (mean level: 2.25 log 10 IU/mL) and 3.2% (mean level: 6.23 log 10 IU/mL), respectively. The cobas HBV test demonstrated linearity (1.15-6.75 log 10 IU/mL, y = 0.95 × 6 + 0.17, r 2  = 0.994). The cobas HBV test showed good correlation with CAP/CTM v2.0, and had good precision and an acceptable limit of detection. The cobas HBV test using the cobas 4800 is a reliable method for quantifying HBV DNA levels in the clinical setting. Copyright © 2018. Published by Elsevier B.V.

  5. Analysis of geophysical logs, at North Penn Area 6 Superfund Site, Lansdale, Montgomery County, Pennsylvania

    USGS Publications Warehouse

    Conger, Randall W.

    1999-01-01

    The U.S. Geological Survey (USGS), as part of technical assistance to the U.S. Environmental Protection Agency (USEPA), collected borehole geophysical log data in 34 industrial, commercial, and public supply wells and 28 monitor wells at the North Penn Area 6 Superfund Site, in Lansdale, Pa., from August 22, 1995, through August 29, 1997. The wells range in depth from 50 to 1,027 feet below land surface and are drilled in Triassic-age shales and siltstones of the Brunswick Group and Lockatong Formation. The geophysical log data were collected to help describe the hydrogeologic framework in the area and to provide guidance in the reconstruction of the 28 monitor wells drilled during summer 1997. At the time of logging, all wells had open-hole construction. The geophysical logs, caliper, fluid-resistivity, and fluid-temperature, and borehole video logs were used to determine the vertical distribution of water-bearing fractures. Heatpulse-flowmeter measurements were used to determine vertical borehole flow under pumping and nonpumping conditions. The most productive fractures generally could be determined from heatpulse-flowmeter measurements under pumping conditions. Vertical borehole flow was measured under nonpumping conditions in most wells that had more than one water-bearing fracture. Upward flow was measured in 35 wells and probably is a result of natural head differences between fractures in the local ground-water-flow system. Downward flow was measured in 11 wells and commonly indicated differences in hydraulic heads of the fractures caused by nearby pumping. Both upward and downward flow was measured in three wells. No flow was detected in eight wells. Natural-gamma-ray logs were used to estimate the attitude of bedding. Thin shale marker beds, shown as spikes of elevated radioactivity in the natural-gamma logs of some wells throughout the area, enable the determination of bedding-plane orientation from three-point correlations. Generally, the marker beds in and near Lansdale strike about N. 48°-60° E. and dip about 11° NW. Acoustic televiewer logs run in selected boreholes indicate that the attitude of many water-bearing fractures commonly is similar to that of bedding.

  6. MAIL LOG, program theory, volume 1. [Scout project automatic data system

    NASA Technical Reports Server (NTRS)

    Harris, D. K.

    1979-01-01

    The program theory used to obtain the software package, MAIL LOG, developed for the Scout Project Automatic Data System, SPADS, is described. The program is written in FORTRAN for the PRIME 300 computer system. The MAIL LOG data base consists of three main subfiles: (1) incoming and outgoing mail correspondence; (2) design information releases and reports; and (3) drawings and engineering orders. All subroutine descriptions, flowcharts, and MAIL LOG outputs are given and the data base design is described.

  7. Inhibition of biofilm formation on the surface of water storage containers using biosand zeolite silver-impregnated clay granular and silver impregnated porous pot filtration systems

    PubMed Central

    Moropeng, Resoketswe Charlotte; Mpenyana-Monyatsi, Lizzy; Momba, Maggie Ndombo Benteke

    2018-01-01

    Development of biofilms occurring on the inner surface of storage vessels offers a suitable medium for the growth of microorganisms and consequently contributes to the deterioration of treated drinking water quality in homes. The aim of this study was to determine whether the two point-of-use technologies (biosand zeolite silver-impregnated clay granular (BSZ-SICG) filter and silver-impregnated porous pot (SIPP) filter) deployed in a rural community of South Africa could inhibit the formation of biofilm on the surface of plastic-based containers generally used by rural households for the storage of their drinking water. Culture-based methods and molecular techniques were used to detect the indicator bacteria (Total coliforms, faecal coliform, E. coli) and pathogenic bacteria (Salmonella spp., Shigella spp. and Vibrio cholerae) in intake water and on the surface of storage vessels containing treated water. Scanning electron microscopy was also used to visualize the development of biofilm. Results revealed that the surface water source used by the Makwane community was heavily contaminated and harboured unacceptably high counts of bacteria (heterotrophic plate count: 4.4–4.3 Log10 CFU/100mL, total coliforms: 2.2 Log10 CFU/100 mL—2.1 Log10 CFU/100 mL, faecal coliforms: 1.9 Log10 CFU/100 mL—1.8 Log10 CFU/100 mL, E. coli: 1.7 Log10 CFU/100 mL—1.6 Log10 CFU/100 mL, Salmonella spp.: 3 Log10 CFU/100 mL -8 CFU/100 mL; Shigella spp. and Vibrio cholerae had 1.0 Log10 CFU/100 mL and 0.8 Log10 CFU/100 mL respectively). Biofilm formation was apparent on the surface of the storage containers with untreated water within 24 h. The silver nanoparticles embedded in the clay of the filtration systems provided an effective barrier for the inhibition of biofilm formation on the surface of household water storage containers. Biofilm formation occurred on the surface of storage plastic vessels containing drinking water treated with the SIPP filter between 14 and 21 days, and on those containing drinking water treated with the BSZ-SICG filter between 3 and 14 days. The attachment of target bacteria on the surface of the coupons inoculated in storage containers ranged from (0.07 CFU/cm2–227.8 CFU/cm2). To effectively prevent the development of biofilms on the surface of container-stored water, which can lead to the recontamination of treated water, plastic storage containers should be washed within 14 days for water treated with the SIPP filter and within 3 days for water treated with the BSZ-SICG filter. PMID:29621296

  8. Inhibition of biofilm formation on the surface of water storage containers using biosand zeolite silver-impregnated clay granular and silver impregnated porous pot filtration systems.

    PubMed

    Budeli, Phumudzo; Moropeng, Resoketswe Charlotte; Mpenyana-Monyatsi, Lizzy; Momba, Maggie Ndombo Benteke

    2018-01-01

    Development of biofilms occurring on the inner surface of storage vessels offers a suitable medium for the growth of microorganisms and consequently contributes to the deterioration of treated drinking water quality in homes. The aim of this study was to determine whether the two point-of-use technologies (biosand zeolite silver-impregnated clay granular (BSZ-SICG) filter and silver-impregnated porous pot (SIPP) filter) deployed in a rural community of South Africa could inhibit the formation of biofilm on the surface of plastic-based containers generally used by rural households for the storage of their drinking water. Culture-based methods and molecular techniques were used to detect the indicator bacteria (Total coliforms, faecal coliform, E. coli) and pathogenic bacteria (Salmonella spp., Shigella spp. and Vibrio cholerae) in intake water and on the surface of storage vessels containing treated water. Scanning electron microscopy was also used to visualize the development of biofilm. Results revealed that the surface water source used by the Makwane community was heavily contaminated and harboured unacceptably high counts of bacteria (heterotrophic plate count: 4.4-4.3 Log10 CFU/100mL, total coliforms: 2.2 Log10 CFU/100 mL-2.1 Log10 CFU/100 mL, faecal coliforms: 1.9 Log10 CFU/100 mL-1.8 Log10 CFU/100 mL, E. coli: 1.7 Log10 CFU/100 mL-1.6 Log10 CFU/100 mL, Salmonella spp.: 3 Log10 CFU/100 mL -8 CFU/100 mL; Shigella spp. and Vibrio cholerae had 1.0 Log10 CFU/100 mL and 0.8 Log10 CFU/100 mL respectively). Biofilm formation was apparent on the surface of the storage containers with untreated water within 24 h. The silver nanoparticles embedded in the clay of the filtration systems provided an effective barrier for the inhibition of biofilm formation on the surface of household water storage containers. Biofilm formation occurred on the surface of storage plastic vessels containing drinking water treated with the SIPP filter between 14 and 21 days, and on those containing drinking water treated with the BSZ-SICG filter between 3 and 14 days. The attachment of target bacteria on the surface of the coupons inoculated in storage containers ranged from (0.07 CFU/cm2-227.8 CFU/cm2). To effectively prevent the development of biofilms on the surface of container-stored water, which can lead to the recontamination of treated water, plastic storage containers should be washed within 14 days for water treated with the SIPP filter and within 3 days for water treated with the BSZ-SICG filter.

  9. An analysis technique for testing log grades

    Treesearch

    Carl A. Newport; William G. O' Regan

    1963-01-01

    An analytical technique that may be used in evaluating log-grading systems is described. It also provides means of comparing two or more grading systems, or a proposed change with the system from which it was developed. The total volume and computed value of lumber from each sample log are the basic data used.

  10. 47 CFR 73.1840 - Retention of logs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... suits upon such claims. (b) Logs may be retained on microfilm, microfiche or other data-storage systems... of logs, stored on data-storage systems, to full-size copies, is required of licensees if requested... converting to a data-storage system pursuant to the requirements of § 73.1800 (c) and (d), (§ 73.1800...

  11. 47 CFR 73.1840 - Retention of logs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... suits upon such claims. (b) Logs may be retained on microfilm, microfiche or other data-storage systems... of logs, stored on data-storage systems, to full-size copies, is required of licensees if requested... converting to a data-storage system pursuant to the requirements of § 73.1800 (c) and (d), (§ 73.1800...

  12. 47 CFR 73.1840 - Retention of logs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... suits upon such claims. (b) Logs may be retained on microfilm, microfiche or other data-storage systems... of logs, stored on data-storage systems, to full-size copies, is required of licensees if requested... converting to a data-storage system pursuant to the requirements of § 73.1800 (c) and (d), (§ 73.1800...

  13. 47 CFR 73.1840 - Retention of logs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... suits upon such claims. (b) Logs may be retained on microfilm, microfiche or other data-storage systems... of logs, stored on data-storage systems, to full-size copies, is required of licensees if requested... converting to a data-storage system pursuant to the requirements of § 73.1800 (c) and (d), (§ 73.1800...

  14. 47 CFR 73.1840 - Retention of logs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... suits upon such claims. (b) Logs may be retained on microfilm, microfiche or other data-storage systems... of logs, stored on data-storage systems, to full-size copies, is required of licensees if requested... converting to a data-storage system pursuant to the requirements of § 73.1800 (c) and (d), (§ 73.1800...

  15. Calculating tissue shear modulus and pressure by 2D log-elastographic methods

    NASA Astrophysics Data System (ADS)

    McLaughlin, Joyce R.; Zhang, Ning; Manduca, Armando

    2010-08-01

    Shear modulus imaging, often called elastography, enables detection and characterization of tissue abnormalities. In this paper the data are two displacement components obtained from successive MR or ultrasound data sets acquired while the tissue is excited mechanically. A 2D plane strain elastic model is assumed to govern the 2D displacement, u. The shear modulus, μ, is unknown and whether or not the first Lamé parameter, λ, is known the pressure p = λ∇ sdot u which is present in the plane strain model cannot be measured and is unreliably computed from measured data and can be shown to be an order one quantity in the units kPa. So here we present a 2D log-elastographic inverse algorithm that (1) simultaneously reconstructs the shear modulus, μ, and p, which together satisfy a first-order partial differential equation system, with the goal of imaging μ (2) controls potential exponential growth in the numerical error and (3) reliably reconstructs the quantity p in the inverse algorithm as compared to the same quantity computed with a forward algorithm. This work generalizes the log-elastographic algorithm in Lin et al (2009 Inverse Problems 25) which uses one displacement component, is derived assuming that the component satisfies the wave equation and is tested on synthetic data computed with the wave equation model. The 2D log-elastographic algorithm is tested on 2D synthetic data and 2D in vivo data from Mayo Clinic. We also exhibit examples to show that the 2D log-elastographic algorithm improves the quality of the recovered images as compared to the log-elastographic and direct inversion algorithms.

  16. Introducing high performance distributed logging service for ACS

    NASA Astrophysics Data System (ADS)

    Avarias, Jorge A.; López, Joao S.; Maureira, Cristián; Sommer, Heiko; Chiozzi, Gianluca

    2010-07-01

    The ALMA Common Software (ACS) is a software framework that provides the infrastructure for the Atacama Large Millimeter Array and other projects. ACS, based on CORBA, offers basic services and common design patterns for distributed software. Every properly built system needs to be able to log status and error information. Logging in a single computer scenario can be as easy as using fprintf statements. However, in a distributed system, it must provide a way to centralize all logging data in a single place without overloading the network nor complicating the applications. ACS provides a complete logging service infrastructure in which every log has an associated priority and timestamp, allowing filtering at different levels of the system (application, service and clients). Currently the ACS logging service uses an implementation of the CORBA Telecom Log Service in a customized way, using only a minimal subset of the features provided by the standard. The most relevant feature used by ACS is the ability to treat the logs as event data that gets distributed over the network in a publisher-subscriber paradigm. For this purpose the CORBA Notification Service, which is resource intensive, is used. On the other hand, the Data Distribution Service (DDS) provides an alternative standard for publisher-subscriber communication for real-time systems, offering better performance and featuring decentralized message processing. The current document describes how the new high performance logging service of ACS has been modeled and developed using DDS, replacing the Telecom Log Service. Benefits and drawbacks are analyzed. A benchmark is presented comparing the differences between the implementations.

  17. Petrophysical evaluation of subterranean formations

    DOEpatents

    Klein, James D; Schoderbek, David A; Mailloux, Jason M

    2013-05-28

    Methods and systems are provided for evaluating petrophysical properties of subterranean formations and comprehensively evaluating hydrate presence through a combination of computer-implemented log modeling and analysis. Certain embodiments include the steps of running a number of logging tools in a wellbore to obtain a variety of wellbore data and logs, and evaluating and modeling the log data to ascertain various petrophysical properties. Examples of suitable logging techniques that may be used in combination with the present invention include, but are not limited to, sonic logs, electrical resistivity logs, gamma ray logs, neutron porosity logs, density logs, NRM logs, or any combination or subset thereof.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulkarni, Varsha P.; Som, Debopam; Morrison, Sean

    We report Keck/Echellette Spectrograph and Imager and Very Large Telescope/Ultraviolet-Visual Echelle Spectrograph observations of three super-damped Lyα quasar absorbers with H i column densities log N{sub H} {sub i} ≥ 21.7 at redshifts 2 ≲ z ≲ 2.5. All three absorbers show similar metallicities (∼−1.3 to −1.5 dex), and dust depletion of Fe, Ni, and Mn. Two of the absorbers show supersolar [S/Zn] and [Si/Zn]. We combine our results with those for other damped Lyα a absorbers (DLAs) to examine trends between N{sub H} {sub i}, metallicity, and dust depletion. A larger fraction of the super-DLAs lie close to ormore » above the line [X/H] = 20.59 − log N{sub H} {sub i} in the metallicity versus N{sub H} {sub i} plot, compared to the less gas-rich DLAs, suggesting that super-DLAs are more likely to be rich in molecules. Unfortunately, our data for Q0230−0334 and Q0743+1421 do not cover H{sub 2} absorption lines. For Q1418+0718, some H{sub 2} lines are covered, but not detected. CO is not detected in any of our absorbers. For DLAs with log N{sub H} {sub i} < 21.7, we confirm strong correlation between metallicity and Fe depletion, and find a correlation between metallicity and Si depletion. For super-DLAs, these correlations are weaker or absent. The absorbers toward Q0230−0334 and Q1418+0718 show potential detections of weak Lyα emission, implying star formation rates of ∼1.6 and ∼0.7 M{sub ⊙} yr{sup −1}, respectively (ignoring dust extinction). Upper limits on the electron densities from C ii*/C ii or Si ii*/Si ii are low, but are higher than the median values in less gas-rich DLAs. Finally, systems with log N{sub H} {sub i} > 21.7 may have somewhat narrower velocity dispersions Δv{sub 90} than the less gas-rich DLAs, and may arise in cooler and/or less turbulent gas.« less

  19. Estimate of standard deviation for a log-transformed variable using arithmetic means and standard deviations.

    PubMed

    Quan, Hui; Zhang, Ji

    2003-09-15

    Analyses of study variables are frequently based on log transformations. To calculate the power for detecting the between-treatment difference in the log scale, we need an estimate of the standard deviation of the log-transformed variable. However, in many situations a literature search only provides the arithmetic means and the corresponding standard deviations. Without individual log-transformed data to directly calculate the sample standard deviation, we need alternative methods to estimate it. This paper presents methods for estimating and constructing confidence intervals for the standard deviation of a log-transformed variable given the mean and standard deviation of the untransformed variable. It also presents methods for estimating the standard deviation of change from baseline in the log scale given the means and standard deviations of the untransformed baseline value, on-treatment value and change from baseline. Simulations and examples are provided to assess the performance of these estimates. Copyright 2003 John Wiley & Sons, Ltd.

  20. LogScope

    NASA Technical Reports Server (NTRS)

    Havelund, Klaus; Smith, Margaret H.; Barringer, Howard; Groce, Alex

    2012-01-01

    LogScope is a software package for analyzing log files. The intended use is for offline post-processing of such logs, after the execution of the system under test. LogScope can, however, in principle, also be used to monitor systems online during their execution. Logs are checked against requirements formulated as monitors expressed in a rule-based specification language. This language has similarities to a state machine language, but is more expressive, for example, in its handling of data parameters. The specification language is user friendly, simple, and yet expressive enough for many practical scenarios. The LogScope software was initially developed to specifically assist in testing JPL s Mars Science Laboratory (MSL) flight software, but it is very generic in nature and can be applied to any application that produces some form of logging information (which almost any software does).

  1. Design and Evaluation of Log-To-Dimension Manufacturing Systems Using System Simulation

    Treesearch

    Wenjie Lin; D. Earl Kline; Philip A. Araman; Janice K. Wiedenbeck

    1995-01-01

    In a recent study of alternative dimension manufacturing systems that produce green hardwood dimension directly fromlogs, it was observed that for Grade 2 and 3 red oak logs, up to 78 and 76 percent of the log scale volume could be converted into clear dimension parts. The potential high yields suggest that this processing system can be a promising technique for...

  2. Designing efficient logging systems for northern hardwoods using equipment production capabilities and costs.

    Treesearch

    R.B. Gardner

    1966-01-01

    Describes a typical logging system used in the Lake and Northeastern States, discusses each step in the operation, and presents a simple method for designing and efficient logging system for such an operation. Points out that a system should always be built around the key piece of equipment, which is usually the skidder. Specific equipment types and their production...

  3. A Kinect-based system for automatic recording of some pigeon behaviors.

    PubMed

    Lyons, Damian M; MacDonall, James S; Cunningham, Kelly M

    2015-12-01

    Contact switches and touch screens are the state of the art for recording pigeons' pecking behavior. Recording other behavior, however, requires a different sensor for each behavior, and some behaviors cannot easily be recorded. We present a flexible and inexpensive image-based approach to detecting and counting pigeon behaviors that is based on the Kinect sensor from Microsoft. Although the system is as easy to set up and use as the standard approaches, it is more flexible because it can record behaviors in addition to key pecking. In this article, we show how both the fast, fine motion of key pecking and the gross body activity of feeding can be measured. Five pigeons were trained to peck at a lighted contact switch, a pigeon key, to obtain food reward. The timing of the pecks and the food reward signals were recorded in a log file using standard equipment. The Kinect-based system, called BehaviorWatch, also measured the pecking and feeding behavior and generated a different log file. For key pecking, BehaviorWatch had an average sensitivity of 95% and a precision of 91%, which were very similar to the pecking measurements from the standard equipment. For detecting feeding activity, BehaviorWatch had a sensitivity of 95% and a precision of 97%. These results allow us to demonstrate that an advantage of the Kinect-based approach is that it can also be reliably used to measure activity other than key pecking.

  4. Diagnosis and monitoring of HCV infection using the cobas® HCV test for use on the cobas® 6800/8800 systems.

    PubMed

    Yao, Joseph D; Young, Stephen; Heilek, Gabrielle M; Marino, Enrique; Paxinos, Ellen E; Marins, Ed G; Valsamakis, Alexandra

    2018-05-01

    Accurate, sensitive, and specific tests for detection and monitoring of hepatitis C virus (HCV) RNA concentrations are essential for diagnosis and management of HCV infections. We evaluated the next-generation reverse-transcription real-time PCR test, cobas ® HCV test for use with the cobas ® 6800/8800 systems ("cobas HCV") by determining its analytical performance characteristics and clinical utility for the diagnosis and therapeutic monitoring of chronic HCV infections. The limit of detection (LOD), linearity, precision, specificity, matrix equivalence of plasma and serum, and quantitative agreement with the COBAS ® AmpliPrep/COBAS ® TaqMan ® HCV Test version 2.0 ("CAP/CTM HCV v2") were evaluated. Clinical utility for the diagnosis of chronic HCV infection was demonstrated by testing plasma from HCV seropositive individuals and comparing results to a nucleic acid amplification test (NAAT) approved for use in the diagnosis of chronic hepatitis C. Clinical specificity was investigated by testing plasma from HCV antibody negative subjects with non-HCV related liver diseases. Utility for monitoring treatment response was defined by testing plasma collected during treatment of HCV genotypes (GT) 1, 2, and 3 and determining positive predictive value (PPV), negative predictive value (NPV) and the odds ratio (OR) for predicting cure (sustained virologic response 12 weeks after treatment cessation, "SVR12"). The cobas HCV test demonstrated an LOD of at least 15 IU/mL and measurable range from 15 to at least 1.0E + 08 IU/mL (1.2-8.0 log 10 IU/mL) for GT 1-6, with high accuracy (≤0.16 log 10 difference) and precision (standard deviation 0.04-0.14 log 10 ) throughout the linear range. Paired plasma and serum samples showed highly correlated performance (R 2  = 0.97). Quantification was 100% specific for HCV in analytical studies. Correlation with CAP/CTM HCV v2 was high in patient samples (mean titer difference: 0.05 log 10 with a 95% CI: 0.03-0.06 log 10 ). For the diagnosis of chronic HCV, positive and negative percent agreement between cobas HCV and the comparator NAAT were 98.8-100% on the cobas 6800 and 8800 systems. Clinical specificity of cobas HCV using samples from HCV antibody negative subjects with non-HCV related liver diseases was 99.6% and 100% on cobas 6800 and 8800 systems. In therapeutic monitoring and SVR12 prediction during experimental treatment for chronic HCV GT 1 infections, undetectable HCV RNA by cobas HCV at different on-treatment weeks had a PPV 76.8%-79.4%, NPV 29.9%-100%, and OR 1.64-47.52. During therapy of HCV GT 2 and GT 3, treatment week 4 and 12 results were: PPV, 84.7% and 75.3%; NPV, 47.8% and 50.0%; OR, 5.09 and 3.05. The cobas HCV test is highly sensitive, specific, and accurate HCV RNA test for GT 1-6. It demonstrates excellent correlation with the FDA-approved CAP/CTM HCV v2 test. It is useful clinically for detection of active HCV infection in individuals that have had a positive anti-HCV antibody test result and in monitoring treatment response. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Micropollutants removal and health risk reduction in a water reclamation and ecological reuse system.

    PubMed

    Ma, Xiaoyan Y; Li, Qiyuan; Wang, Xiaochang C; Wang, Yongkun; Wang, Donghong; Ngo, Huu Hao

    2018-07-01

    As reclaimed water use is increasing, its safety attracts growing attention, particularly with respect to the health risks associated with the wide range of micropollutants found in the reclaimed water. In this study, sophisticated analysis was conducted for water samples from a water reclamation and ecological reuse system where domestic wastewater was treated using an anaerobic-anoxic-oxic unit followed by a membrane bioreactor (A 2 O-MBR), and the reclaimed water was used for replenishing a landscape lake. A total of 58 organic micropollutants were detected in the system, consisting of 13 polycyclic aromatic hydrocarbons (PAHs), 16 phenols, 3 pesticides, and 26 pharmaceuticals and personal care products (PPCPs). After treatment by the A 2 O-MBR process, effective removal of pesticides and phenols was achieved, while when the reclaimed water entered the landscape lake, PPCPs were further removed. From the physicochemical properties of micropollutants, it could be inferred that phenols and dichlorphos (the only pesticide with considerable concentration in the influent) would have been mainly removed by biodegradation and/or volatilization in the biological treatment process. Additionally, it is probable that sludge adsorption also contributed to the removal of dichlorphos. For the predominant PPCP removal in the landscape lake, various actions, such as adsorption, biodegradation, photolysis, and ecologically mediated processes (via aquatic plants and animals), would have played significant roles. However, according to their logK oc , logK ow and logD (pH = 8) values, it could be concluded that adsorption by suspended solids might be an important action. Although carcinogenic and non-carcinogenic risks associated with all the detected micropollutants were at negligible levels, the hazard quotients (HQs) of PPCPs accounted for 92.03%-97.23% of the HQ Total . With the significant removal of PPCPs through the ecological processes in the landscape lake, the safety of reclaimed water use could be improved. Therefore, the introduction of ecological unit into the water reclamation and reuse system could be an effective measure for health risk reduction posed by micropollutants. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Monocular perceptual learning of contrast detection facilitates binocular combination in adults with anisometropic amblyopia.

    PubMed

    Chen, Zidong; Li, Jinrong; Liu, Jing; Cai, Xiaoxiao; Yuan, Junpeng; Deng, Daming; Yu, Minbin

    2016-02-01

    Perceptual learning in contrast detection improves monocular visual function in adults with anisometropic amblyopia; however, its effect on binocular combination remains unknown. Given that the amblyopic visual system suffers from pronounced binocular functional loss, it is important to address how the amblyopic visual system responds to such training strategies under binocular viewing conditions. Anisometropic amblyopes (n = 13) were asked to complete two psychophysical supra-threshold binocular summation tasks: (1) binocular phase combination and (2) dichoptic global motion coherence before and after monocular training to investigate this question. We showed that these participants benefited from monocular training in terms of binocular combination. More importantly, the improvements observed with the area under log CSF (AULCSF) were found to be correlated with the improvements in binocular phase combination.

  7. Monocular perceptual learning of contrast detection facilitates binocular combination in adults with anisometropic amblyopia

    PubMed Central

    Chen, Zidong; Li, Jinrong; Liu, Jing; Cai, Xiaoxiao; Yuan, Junpeng; Deng, Daming; Yu, Minbin

    2016-01-01

    Perceptual learning in contrast detection improves monocular visual function in adults with anisometropic amblyopia; however, its effect on binocular combination remains unknown. Given that the amblyopic visual system suffers from pronounced binocular functional loss, it is important to address how the amblyopic visual system responds to such training strategies under binocular viewing conditions. Anisometropic amblyopes (n = 13) were asked to complete two psychophysical supra-threshold binocular summation tasks: (1) binocular phase combination and (2) dichoptic global motion coherence before and after monocular training to investigate this question. We showed that these participants benefited from monocular training in terms of binocular combination. More importantly, the improvements observed with the area under log CSF (AULCSF) were found to be correlated with the improvements in binocular phase combination. PMID:26829898

  8. THE DOUBLE-DEGENERATE NUCLEUS OF THE PLANETARY NEBULA TS 01: A CLOSE BINARY EVOLUTION SHOWCASE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tovmassian, Gagik; Richer, Michael G.; Yungelson, Lev

    2010-05-01

    We present a detailed investigation of SBS 1150+599A, a close binary star hosted by the planetary nebula PN G135.9+55.9 (TS 01). The nebula, located in the Galactic halo, is the most oxygen-poor known to date and is the only one known to harbor a double degenerate core. We present XMM-Newton observations of this object, which allowed the detection of the previously invisible component of the binary core, whose existence was inferred so far only from radial velocity (RV) and photometric variations. The parameters of the binary system were deduced from a wealth of information via three independent routes using themore » spectral energy distribution (from the infrared to X-rays), the light and RV curves, and a detailed model atmosphere fitting of the stellar absorption features of the optical/UV component. We find that the cool component must have a mass of 0.54 {+-} 0.2 M{sub sun}, an average effective temperature, T{sub eff}, of 58,000 {+-} 3000 K, a mean radius of 0.43 {+-} 0.3 R{sub sun}, a gravity, log g = 5.0 {+-} 0.3, and that it nearly fills its Roche lobe. Its surface elemental abundances are found to be: 12 + log He/H = 10.95 {+-} 0.04 dex, 12 + log C/H = 7.20 {+-} 0.3 dex, 12 + log N/H < 6.92, and 12 + log O/H < 6.80, in overall agreement with the chemical composition of the planetary nebula. The hot component has T{sub eff} = 160-180 kK, a luminosity of about {approx}10{sup 4} L{sub sun} and a radius slightly larger than that of a white dwarf. It is probably bloated and heated as a result of intense accretion and nuclear burning on its surface in the past. The total mass of the binary system is very close to the Chandrasekhar limit. This makes TS 01 one of the best Type Ia supernova progenitor candidates. We propose two possible scenarios for the evolution of the system up to its present stage.« less

  9. Process modeling and bottleneck mining in online peer-review systems.

    PubMed

    Premchaiswadi, Wichian; Porouhan, Parham

    2015-01-01

    This paper is divided into three main parts. In the first part of the study, we captured, collected and formatted an event log describing the handling of reviews for proceedings of an international conference in Thailand. In the second part, we used several process mining techniques in order to discover process models, social, organizational, and hierarchical structures from the proceeding's event log. In the third part, we detected the deviations and bottlenecks of the peer review process by comparing the observed events (i.e., authentic dataset) with a pre-defined model (i.e., master map). Finally, we investigated the performance information as well as the total waiting time in order to improve the effectiveness and efficiency of the online submission and peer review system for the prospective conferences and seminars. Consequently, the main goals of the study were as follows: (1) to convert the collected event log into the appropriate format supported by process mining analysis tools, (2) to discover process models and to construct social networks based on the collected event log, and (3) to find deviations, discrepancies and bottlenecks between the collected event log and the master pre-defined model. The results showed that although each paper was initially sent to three different reviewers; it was not always possible to make a decision after the first round of reviewing; therefore, additional reviewers were invited. In total, all the accepted and rejected manuscripts were reviewed by an average of 3.9 and 3.2 expert reviewers, respectively. Moreover, obvious violations of the rules and regulations relating to careless or inappropriate peer review of a manuscript-committed by the editorial board and other staff-were identified. Nine blocks of activity in the authentic dataset were not completely compatible with the activities defined in the master model. Also, five of the activity traces were not correctly enabled, and seven activities were missed within the online submission system. On the other hand, dealing with the feedback (comments) received from the first and the third reviewers; the conference committee members and the organizers did not attend to those feedback/comments in a timely manner.

  10. Distribution and characterization of in-channel large wood in relation to geomorphic patterns on a low-gradient river

    USGS Publications Warehouse

    Moulin, Bertrand; Schenk, Edward R.; Hupp, Cliff R.

    2011-01-01

    A 177 river km georeferenced aerial survey of in-channel large wood (LW) on the lower Roanoke River, NC was conducted to determine LW dynamics and distributions on an eastern USA low-gradient large river. Results indicate a system with approximately 75% of the LW available for transport either as detached individual LW or as LW in log jams. There were approximately 55 individual LW per river km and another 59 pieces in log jams per river km. Individual LW is a product of bank erosion (73% is produced through erosion) and is isolated on the mid and upper banks at low flow. This LW does not appear to be important for either aquatic habitat or as a human risk. Log jams rest near or at water level making them a factor in bank complexity in an otherwise homogenous fine-grained channel. A segmentation test was performed using LW frequency by river km to detect breaks in longitudinal distribution and to define homogeneous reaches of LWfrequency. Homogeneous reaches were then analyzed to determine their relationship to bank height, channel width/depth, sinuosity, and gradient. Results show that log jams are a product of LW transport and occur more frequently in areas with high snag concentrations, low to intermediate bank heights, high sinuosity, high local LW recruitment rates, and narrow channel widths. The largest concentration of log jams (21.5 log jams/km) occurs in an actively eroding reach. Log jam concentrations downstream of this reach are lower due to a loss of river competency as the channel reaches sea level and the concurrent development of unvegetated mudflats separating the active channel from the floodplain forest. Substantial LW transport occurs on this low-gradient, dam-regulated large river; this study, paired with future research on transport mechanisms should provide resource managers and policymakers with options to better manage aquatic habitat while mitigating possible negative impacts to human interests.

  11. Explosive hazard detection using MIMO forward-looking ground penetrating radar

    NASA Astrophysics Data System (ADS)

    Shaw, Darren; Ho, K. C.; Stone, Kevin; Keller, James M.; Popescu, Mihail; Anderson, Derek T.; Luke, Robert H.; Burns, Brian

    2015-05-01

    This paper proposes a machine learning algorithm for subsurface object detection on multiple-input-multiple-output (MIMO) forward-looking ground-penetrating radar (FLGPR). By detecting hazards using FLGPR, standoff distances of up to tens of meters can be acquired, but this is at the degradation of performance due to high false alarm rates. The proposed system utilizes an anomaly detection prescreener to identify potential object locations. Alarm locations have multiple one-dimensional (ML) spectral features, two-dimensional (2D) spectral features, and log-Gabor statistic features extracted. The ability of these features to reduce the number of false alarms and increase the probability of detection is evaluated for both co-polarizations present in the Akela MIMO array. Classification is performed by a Support Vector Machine (SVM) with lane-based cross-validation for training and testing. Class imbalance and optimized SVM kernel parameters are considered during classifier training.

  12. VizieR Online Data Catalog: Double stars with wide separations in the AGK3 (Halbwachs+, 2016)

    NASA Astrophysics Data System (ADS)

    Halbwachs, J. L.; Mayor, M.; Udry, S.

    2016-10-01

    A large list of common proper motion stars selected from the third Astronomischen Gesellschaft Katalog (AGK3) was monitored with the CORAVEL (for COrrelation RAdial VELocities) spectrovelocimeter, in order to prepare a sample of physical binaries with very wide separations. In paper I,66 stars received special attention, since their radial velocities (RV) seemed to be variable. These stars were monitored over several years in order to derive the elements of their spectroscopic orbits. In addition, 10 of them received accurate RV measurements from the SOPHIE spectrograph of the T193 telescope at the Observatory of Haute-Provence. For deriving the orbital elements of double-lined spectroscopic binaries (SB2s), a new method was applied, which assumed that the RV of blended measurements are linear combinations of the RV of the components. 13 SB2 orbits were thus calculated. The orbital elements were eventually obtained for 52 spectroscopic binaries (SBs), two of them making a triple system. 40 SBs received their first orbit and the orbital elements were improved for 10 others. In addition, 11 SBs were discovered with very long periods for which the orbital parameters were not found. It appeared that HD 153252 has a close companion, which is a candidate brown dwarf with a minimum mass of 50 Jupiter masses. In paper II, 80 wide binaries (WBs) were detected, and 39 optical pairs were identified. Adding CPM stars with separations close enough to be almost certain they are physical, a "bias-controlled" sample of 116 wide binaries was obtained, and used to derive the distribution of separations from 100 to 30,000 au. The distribution obtained doesn't match the log-constant distribution, but is in agreement with the log-normal distribution. The spectroscopic binaries detected among the WB components were used to derive statistical informations about the multiple systems. The close binaries in WBs seem to be similar to those detected in other field stars. As for the WBs, they seem to obey the log-normal distribution of periods. The number of quadruple systems is in agreement with the "no correlation" hypothesis; this indicates that an environment conducive to the formation of WBs doesn't favor the formation of subsystems with periods shorter than 10 years. (9 data files).

  13. The economic potential of CT scanners for hardwood sawmills

    Treesearch

    Donald G. Hodges; Walter C. Anderson; Charles W. McMillin

    1990-01-01

    Research has demonstrated that a knowledge of internal log defects prior to sawing could improve lumber value yields significantly. This study evaluated the potential economic returns from investments in computerized tomographic (CT) scanners to detect internal defects in hardwood logs at southern sawmills. The results indicate that such investments would be profitable...

  14. Integrating PCLIPS into ULowell's Lincoln Logs: Factory of the future

    NASA Technical Reports Server (NTRS)

    Mcgee, Brenda J.; Miller, Mark D.; Krolak, Patrick; Barr, Stanley J.

    1990-01-01

    We are attempting to show how independent but cooperating expert systems, executing within a parallel production system (PCLIPS), can operate and control a completely automated, fault tolerant prototype of a factory of the future (The Lincoln Logs Factory of the Future). The factory consists of a CAD system for designing the Lincoln Log Houses, two workcells, and a materials handling system. A workcell consists of two robots, part feeders, and a frame mounted vision system.

  15. Cloud object store for checkpoints of high performance computing applications using decoupling middleware

    DOEpatents

    Bent, John M.; Faibish, Sorin; Grider, Gary

    2016-04-19

    Cloud object storage is enabled for checkpoints of high performance computing applications using a middleware process. A plurality of files, such as checkpoint files, generated by a plurality of processes in a parallel computing system are stored by obtaining said plurality of files from said parallel computing system; converting said plurality of files to objects using a log structured file system middleware process; and providing said objects for storage in a cloud object storage system. The plurality of processes may run, for example, on a plurality of compute nodes. The log structured file system middleware process may be embodied, for example, as a Parallel Log-Structured File System (PLFS). The log structured file system middleware process optionally executes on a burst buffer node.

  16. A complete low cost radon detection system.

    PubMed

    Bayrak, A; Barlas, E; Emirhan, E; Kutlu, Ç; Ozben, C S

    2013-08-01

    Monitoring the (222)Rn activity through the 1200 km long Northern Anatolian fault line, for the purpose of earthquake precursory, requires large number of cost effective radon detectors. We have designed, produced and successfully tested a low cost radon detection system (a radon monitor). In the detector circuit of this monitor, First Sensor PS100-7-CER-2 windowless PIN photodiode and a custom made transempedence/shaping amplifier were used. In order to collect the naturally ionized radon progeny to the surface of the PIN photodiode, a potential of 3500 V was applied between the conductive hemi-spherical shell and the PIN photodiode. In addition to the count rate of the radon progeny, absolute pressure, humidity and temperature were logged during the measurements. A GSM modem was integrated to the system for transferring the measurements from the remote locations to the data process center. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Structural Acoustic UXO Detection and Identification in Marine Environments

    DTIC Science & Technology

    2016-05-01

    BOSS Buried Object Scanning Sonar DVL Doppler Velocity Log EW East/West IMU Inertial Measurement Unit NRL Naval Research Laboratory NSWC-PCD... Inertial Measurement Unit (IMU) to time-delay and coherently sum matched-filtered phase histories from subsurface focal points over a large number of... Measurement Unit (IMU) systems. In our imaging algorithm, the 2D depth image of a target, i.e. one mapped over x and z or y and z, presents the

  18. Microbiological quality of a waste stabilization pond effluent used for restricted irrigation in Valle Del Cauca, Colombia.

    PubMed

    Madera, C A; Peña, M R; Mara, D D

    2002-01-01

    This paper discusses the applicability of effluent reuse in agriculture after treatment in a series of anaerobic, facultative and maturation ponds. The WSP system is located in Ginebra municipality, a small town in southwest Colombia. The total HRT is 12 days. Several samples of the final effluent were taken over a 55 day period and were analysed for E. coli, Streptococcus spp. and helminth eggs. Some additional grab samples were taken to determine the presence of pathogenic bacteria such as Salmonella spp. and Shigella spp. The results showed that the system was able to remove 4 log units of E. coli, 1 log unit of Streptococcus spp. and 100% of helminth eggs. Meanwhile, Salmonella spp. were detected in the effluent of the facultative pond whilst Shigella spp. were not detected in any sample. The main species of helminth eggs encountered were Taenia spp., Ascaris spp., Trichuris spp., Hymenolepis nana, H. diminuta and Enterobius vermicularis. Removal efficiencies were satisfactory despite the relatively short HRT. Nevertheless, WHO guidelines were slightly surpassed in the case of E. coli for unrestricted irrigation. The helminth egg value was always below the maximum WHO limit. Hence, this effluent can be safely used for restricted irrigation provided that field workers are protected from direct contact with wastewater given the presence of Salmonella spp. in the facultative pond effluent.

  19. Web usage data mining agent

    NASA Astrophysics Data System (ADS)

    Madiraju, Praveen; Zhang, Yanqing

    2002-03-01

    When a user logs in to a website, behind the scenes the user leaves his/her impressions, usage patterns and also access patterns in the web servers log file. A web usage mining agent can analyze these web logs to help web developers to improve the organization and presentation of their websites. They can help system administrators in improving the system performance. Web logs provide invaluable help in creating adaptive web sites and also in analyzing the network traffic analysis. This paper presents the design and implementation of a Web usage mining agent for digging in to the web log files.

  20. Automated Detection of Selective Logging in Amazon Forests Using Airborne Lidar Data and Pattern Recognition Algorithms

    NASA Astrophysics Data System (ADS)

    Keller, M. M.; d'Oliveira, M. N.; Takemura, C. M.; Vitoria, D.; Araujo, L. S.; Morton, D. C.

    2012-12-01

    Selective logging, the removal of several valuable timber trees per hectare, is an important land use in the Brazilian Amazon and may degrade forests through long term changes in structure, loss of forest carbon and species diversity. Similar to deforestation, the annual area affected by selected logging has declined significantly in the past decade. Nonetheless, this land use affects several thousand km2 per year in Brazil. We studied a 1000 ha area of the Antimary State Forest (FEA) in the State of Acre, Brazil (9.304 ○S, 68.281 ○W) that has a basal area of 22.5 m2 ha-1 and an above-ground biomass of 231 Mg ha-1. Logging intensity was low, approximately 10 to 15 m3 ha-1. We collected small-footprint airborne lidar data using an Optech ALTM 3100EA over the study area once each in 2010 and 2011. The study area contained both recent and older logging that used both conventional and technologically advanced logging techniques. Lidar return density averaged over 20 m-2 for both collection periods with estimated horizontal and vertical precision of 0.30 and 0.15 m. A relative density model comparing returns from 0 to 1 m elevation to returns in 1-5 m elevation range revealed the pattern of roads and skid trails. These patterns were confirmed by ground-based GPS survey. A GIS model of the road and skid network was built using lidar and ground data. We tested and compared two pattern recognition approaches used to automate logging detection. Both segmentation using commercial eCognition segmentation and a Frangi filter algorithm identified the road and skid trail network compared to the GIS model. We report on the effectiveness of these two techniques.

  1. Spotting high-z molecular absorbers using neutral carbon. Results from a complete spectroscopic survey with the VLT

    NASA Astrophysics Data System (ADS)

    Noterdaeme, P.; Ledoux, C.; Zou, S.; Petitjean, P.; Srianand, R.; Balashev, S.; López, S.

    2018-04-01

    While molecular quasar absorption systems provide unique probes of the physical and chemical properties of the gas as well as original constraints on fundamental physics and cosmology, their detection remains challenging. Here we present the results from a complete survey for molecular gas in thirty-nine absorption systems selected solely upon the detection of neutral carbon lines in Sloan Digital Sky Survey (SDSS) spectra, without any prior knowledge of the atomic or molecular gas content. H2 is found in all twelve systems (including seven new detections) where the corresponding lines are covered by the instrument setups and measured to have logN(H2) ≳ 18, indicating a self-shielded regime. We also report seven CO detections (7/39) down to logN(CO) 13.5, including a new one, and put stringent constraints on N(CO) for the remaining 32 systems. N(CO) and N(C I) are found to be strongly correlated with N(CO)/N(C I) 1/10. This suggests that the C I-selected absorber population is probing gas deeper than the H I–H2 transition in which a substantial fraction of the total hydrogen in the cloud is in the form of H2. We conclude that targeting C I-bearing absorbers is a very efficient way to find high-metallicity molecular absorbers. However, probing the molecular content in lower-metallicity regimes as well as high-column-density neutral gas remains to be undertaken to unravel the processes of gas conversion in normal high-z galaxies. Based on observations and archival data from the European Southern Observatory (ESO) prog. IDs 060.A-9024, 072.A-0346, 278.A-5062, 080.A-0482, 080.A-0795, 081.A-0242, 081.A-0334, 082.A-0544, 082.A-0569, 083.A-0454, 084.A-0699, 086.A-0074 and 086.A-0643 using the Ultraviolet and Visual Echelle Spectrograph (UVES) and X-shooter at the Very Large Telescope (VLT), on Cerro Paranal, Chile.

  2. Reduction of lithologic-log data to numbers for use in the digital computer

    USGS Publications Warehouse

    Morgan, C.O.; McNellis, J.M.

    1971-01-01

    The development of a standardized system for conveniently coding lithologic-log data for use in the digital computer has long been needed. The technique suggested involves a reduction of the original written alphanumeric log to a numeric log by use of computer programs. This numeric log can then be retrieved as a written log, interrogated for pertinent information, or analyzed statistically. ?? 1971 Plenum Publishing Corporation.

  3. Log Truck-Weighing System

    NASA Technical Reports Server (NTRS)

    1977-01-01

    ELDEC Corp., Lynwood, Wash., built a weight-recording system for logging trucks based on electronic technology the company acquired as a subcontractor on space programs such as Apollo and the Saturn launch vehicle. ELDEC employed its space-derived expertise to develop a computerized weight-and-balance system for Lockheed's TriStar jetliner. ELDEC then adapted the airliner system to a similar product for logging trucks. Electronic equipment computes tractor weight, trailer weight and overall gross weight, and this information is presented to the driver by an instrument in the cab. The system costs $2,000 but it pays for itself in a single year. It allows operators to use a truck's hauling capacity more efficiently since the load can be maximized without exceeding legal weight limits for highway travel. Approximately 2,000 logging trucks now use the system.

  4. Efficacy, efficiency and safety aspects of hydrogen peroxide vapour and aerosolized hydrogen peroxide room disinfection systems.

    PubMed

    Fu, T Y; Gent, P; Kumar, V

    2012-03-01

    This was a head-to-head comparison of two hydrogen-peroxide-based room decontamination systems. To compare the efficacy, efficiency and safety of hydrogen peroxide vapour (HPV; Clarus R, Bioquell, Andover, U.K.) and aerosolized hydrogen peroxide (aHP; SR2, Sterinis, now supplied as Glosair, Advanced Sterilization Products (ASP), Johnson & Johnson Medical Ltd, Wokingham, U.K.) room disinfection systems. Efficacy was tested using 4- and 6-log Geobacillus stearothermophilus biological indicators (BIs) and in-house prepared test discs containing approximately 10(6) meticillin-resistant Staphylococcus aureus (MRSA), Clostridium difficile and Acinetobacter baumannii. Safety was assessed by detecting leakage of hydrogen peroxide using a hand-held detector. Efficiency was assessed by measuring the level of hydrogen peroxide using a hand-held sensor at three locations inside the room, 2 h after the start of the cycles. HPV generally achieved a 6-log reduction, whereas aHP generally achieved less than a 4-log reduction on the BIs and in-house prepared test discs. Uneven distribution was evident for the aHP system but not the HPV system. Hydrogen peroxide leakage during aHP cycles with the door unsealed, as per the manufacturer's operating manual, exceeded the short-term exposure limit (2 ppm) for more than 2 h. When the door was sealed with tape, as per the HPV system, hydrogen peroxide leakage was <1 ppm for both systems. The mean concentration of hydrogen peroxide in the room 2 h after the cycle started was 1.3 [standard deviation (SD) 0.4] ppm and 2.8 (SD 0.8) ppm for the four HPV and aHP cycles, respectively. None of the readings were <2 ppm for the aHP cycles. The HPV system was safer, faster and more effective for biological inactivation. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  5. Agnostic stacking of intergalactic doublet absorption: measuring the Ne VIII population

    NASA Astrophysics Data System (ADS)

    Frank, Stephan; Pieri, Matthew M.; Mathur, Smita; Danforth, Charles W.; Shull, J. Michael

    2018-05-01

    We present a blind search for doublet intergalactic metal absorption with a method dubbed `agnostic stacking'. Using a forward-modelling framework, we combine this with direct detections in the literature to measure the overall metal population. We apply this novel approach to the search for Ne VIII absorption in a set of 26 high-quality COS spectra. We probe to an unprecedented low limit of log N>12.3 at 0.47≤z ≤1.34 over a path-length Δz = 7.36. This method selects apparent absorption without requiring knowledge of its source. Stacking this mixed population dilutes doublet features in composite spectra in a deterministic manner, allowing us to measure the proportion corresponding to Ne VIII absorption. We stack potential Ne VIII absorption in two regimes: absorption too weak to be significant in direct line studies (12.3 < log N < 13.7), and strong absorbers (log N > 13.7). We do not detect Ne VIII absorption in either regime. Combining our measurements with direct detections, we find that the Ne VIII population is reproduced with a power-law column density distribution function with slope β = -1.86 ^{+0.18 }_{ -0.26} and normalization log f_{13.7} = -13.99 ^{+0.20 }_{ -0.23}, leading to an incidence rate of strong Ne VIII absorbers dn/dz =1.38 ^{+0.97 }_{ -0.82}. We infer a cosmic mass density for Ne VIII gas with 12.3 < log N < 15.0 of Ω _{{{Ne {VIII}}}} = 2.2 ^{+1.6 }_{ _-1.2} × 10^{-8}, a value significantly lower that than predicted by recent simulations. We translate this density into an estimate of the baryon density Ωb ≈ 1.8 × 10-3, constituting 4 per cent of the total baryonic mass.

  6. Cloud object store for archive storage of high performance computing data using decoupling middleware

    DOEpatents

    Bent, John M.; Faibish, Sorin; Grider, Gary

    2015-06-30

    Cloud object storage is enabled for archived data, such as checkpoints and results, of high performance computing applications using a middleware process. A plurality of archived files, such as checkpoint files and results, generated by a plurality of processes in a parallel computing system are stored by obtaining the plurality of archived files from the parallel computing system; converting the plurality of archived files to objects using a log structured file system middleware process; and providing the objects for storage in a cloud object storage system. The plurality of processes may run, for example, on a plurality of compute nodes. The log structured file system middleware process may be embodied, for example, as a Parallel Log-Structured File System (PLFS). The log structured file system middleware process optionally executes on a burst buffer node.

  7. Detecting post-fire salvage logging with Landsat change maps and national fire survey data

    Treesearch

    Todd A. Schroeder; Michael A. Wulder; Sean P. Healey; Gretchen G. Moisen

    2012-01-01

    In Canadian boreal forests, wildfire is the predominant agent of natural disturbance often with millions of hectares burning annually. In addition to fire, nearly one quarter of Canada's boreal forest is also managed for industrial wood production. Post-fire logging (or salvage harvesting) is increasingly used to minimize economic losses from fire, notwithstanding...

  8. Image based automatic water meter reader

    NASA Astrophysics Data System (ADS)

    Jawas, N.; Indrianto

    2018-01-01

    Water meter is used as a tool to calculate water consumption. This tool works by utilizing water flow and shows the calculation result with mechanical digit counter. Practically, in everyday use, an operator will manually check the digit counter periodically. The Operator makes logs of the number shows by water meter to know the water consumption. This manual operation is time consuming and prone to human error. Therefore, in this paper we propose an automatic water meter digit reader from digital image. The digits sequence is detected by utilizing contour information of the water meter front panel.. Then an OCR method is used to get the each digit character. The digit sequence detection is an important part of overall process. It determines the success of overall system. The result shows promising results especially in sequence detection.

  9. Prevalence and Association of Escherichia coli and Diarrheagenic Escherichia coli in Stored Foods for Young Children and Flies Caught in the Same Households in Rural Bangladesh

    PubMed Central

    Doza, Solaiman; Jabeen Rahman, Musarrat; Islam, Mohammad Aminul; Kwong, Laura H.; Unicomb, Leanne; Ercumen, Ayse; Pickering, Amy J.; Parvez, Sarker Masud; Naser, Abu Mohd; Ashraf, Sania; Das, Kishor Kumar; Luby, Stephen P.

    2018-01-01

    Abstract. Consumption of contaminated stored food can cause childhood diarrhea. Flies carry enteropathogens, although their contribution to food contamination remains unclear. We investigated the role of flies in contaminating stored food by collecting food and flies from the same households in rural Bangladesh. We selected 182 households with children ≤ 24 months old that had stored foods for later feeding at room temperature for ≥ 3 hours. We collected food samples and captured flies with fly tapes hung by the kitchen. We used the IDEXX Quanti-Tray System (Colilert-18 media; IDEXX Laboratories, Inc., Westbrook, ME) to enumerate Escherichia coli with the most probable number (MPN) method. Escherichia coli–positive IDEXX wells were analyzed by polymerase chain reaction for pathogenic E. coli genes (eae, ial, bfp, ipaH, st, lt, aat, aaiC, stx1, and stx2). Escherichia coli was detected in 61% (111/182) of food samples, with a mean of 1.1 log10 MPN/dry g. Fifteen samples (8%) contained pathogenic E. coli; seven (4%) had enteropathogenic E. coli (EPEC) genes (eae and/or bfp); and 10 (5%) had enteroaggregative E. coli genes (aat and/or aaiC). Of flies captured in 68 (37%) households, E. coli was detected in 41 (60%, mean 2.9 log10 MPN/fly), and one fly (1%) had an EPEC gene (eae). For paired fly-food samples, each log10 MPN E. coli increase in flies was associated with a 0.31 log10 MPN E. coli increase in stored food (95% confidence interval: 0.07, 0.55). In rural Bangladesh, flies possibly a likely route for fecal contamination of stored food. Controlling fly populations may reduce contamination of food stored for young children. PMID:29436348

  10. Microbiological Food Safety Status of Commercially Produced Tomatoes from Production to Marketing.

    PubMed

    van Dyk, Brigitte N; de Bruin, Willeke; du Plessis, Erika M; Korsten, Lise

    2016-03-01

    Tomatoes have been implicated in various microbial disease outbreaks and are considered a potential vehicle for foodborne pathogens. Traceback studies mostly implicate contamination during production and/or processing. The microbiological quality of commercially produced tomatoes was thus investigated from the farm to market, focusing on the impact of contaminated irrigation and washing water, facility sanitation, and personal hygiene. A total of 905 samples were collected from three largescale commercial farms from 2012 through 2014. The farms differed in water sources used (surface versus well) and production methods (open field versus tunnel). Levels of total coliforms and Escherichia coli and prevalence of E. coli O157:H7 and Salmonella Typhimurium were determined. Dominant coliforms were identified using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. No pathogens or E. coli were detected on any of the tomatoes tested throughout the study despite the high levels of coliforms (4.2 to 6.2 log CFU/g) present on the tomatoes at the market. The dominant species associated with tomatoes belonged to the genera Enterobacter, Klebsiella, and Citrobacter. Water used on the farm for irrigation considered not fit for purpose according to national agricultural irrigation standards, with high E. coli levels resulting from either a highly contaminated source water (river water at 3.19 log most probable number [MPN]/100 ml) or improper storage of source water (stored well water at 1.72 log MPN/100 ml). Salmonella Typhimurium was detected on two occasions on a contact surface in the processing facility of the first farm in 2012. Contact surface coliform counts were 2.9 to 4.8 log CFU/cm(2). Risk areas identified in this study were water used for irrigation and poor sanitation practices in the processing facility. Implementation of effective food safety management systems in the fresh produce industry is of the utmost importance to ensure product safety for consumers.

  11. Landslide seismic magnitude

    NASA Astrophysics Data System (ADS)

    Lin, C. H.; Jan, J. C.; Pu, H. C.; Tu, Y.; Chen, C. C.; Wu, Y. M.

    2015-11-01

    Landslides have become one of the most deadly natural disasters on earth, not only due to a significant increase in extreme climate change caused by global warming, but also rapid economic development in topographic relief areas. How to detect landslides using a real-time system has become an important question for reducing possible landslide impacts on human society. However, traditional detection of landslides, either through direct surveys in the field or remote sensing images obtained via aircraft or satellites, is highly time consuming. Here we analyze very long period seismic signals (20-50 s) generated by large landslides such as Typhoon Morakot, which passed though Taiwan in August 2009. In addition to successfully locating 109 large landslides, we define landslide seismic magnitude based on an empirical formula: Lm = log ⁡ (A) + 0.55 log ⁡ (Δ) + 2.44, where A is the maximum displacement (μm) recorded at one seismic station and Δ is its distance (km) from the landslide. We conclude that both the location and seismic magnitude of large landslides can be rapidly estimated from broadband seismic networks for both academic and applied purposes, similar to earthquake monitoring. We suggest a real-time algorithm be set up for routine monitoring of landslides in places where they pose a frequent threat.

  12. Fast log P determination by ultra-high-pressure liquid chromatography coupled with UV and mass spectrometry detections.

    PubMed

    Henchoz, Yveline; Guillarme, Davy; Martel, Sophie; Rudaz, Serge; Veuthey, Jean-Luc; Carrupt, Pierre-Alain

    2009-08-01

    Ultra-high-pressure liquid chromatography (UHPLC) systems able to work with columns packed with sub-2 microm particles offer very fast methods to determine the lipophilicity of new chemical entities. The careful development of the most suitable experimental conditions presented here will help medicinal chemists for high-throughput screening (HTS) log P(oct) measurements. The approach was optimized using a well-balanced set of 38 model compounds and a series of 28 basic compounds such as beta-blockers, local anesthetics, piperazines, clonidine, and derivatives. Different organic modifiers and hybrid stationary phases packed with 1.7-microm particles were evaluated in isocratic as well as gradient modes, and the advantages and limitations of tested conditions pointed out. The UHPLC approach offered a significant enhancement over the classical HPLC methods, by a factor 50 in the lipophilicity determination throughput. The hyphenation of UHPLC with MS detection allowed a further increase in the throughput. Data and results reported herein prove that the UHPLC-MS method can represent a progress in the HTS-measurement of lipophilicity due to its speed (at least a factor of 500 with respect to HPLC approaches) and to an extended field of application.

  13. A European multicenter study on the analytical performance of the VERIS HBV assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Maria Angeles; Sauné, Karine; O Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. Precision showed an SD of 0.15 log 10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log 10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. 10 CFR 39.33 - Radiation detection instruments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Radiation detection instruments. 39.33 Section 39.33 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Equipment § 39.33 Radiation detection instruments. (a) The licensee shall keep a calibrated and operable...

  15. 10 CFR 39.33 - Radiation detection instruments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Radiation detection instruments. 39.33 Section 39.33 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Equipment § 39.33 Radiation detection instruments. (a) The licensee shall keep a calibrated and operable...

  16. 10 CFR 39.33 - Radiation detection instruments.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Radiation detection instruments. 39.33 Section 39.33 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Equipment § 39.33 Radiation detection instruments. (a) The licensee shall keep a calibrated and operable...

  17. 10 CFR 39.33 - Radiation detection instruments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation detection instruments. 39.33 Section 39.33 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Equipment § 39.33 Radiation detection instruments. (a) The licensee shall keep a calibrated and operable...

  18. 10 CFR 39.33 - Radiation detection instruments.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Radiation detection instruments. 39.33 Section 39.33 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Equipment § 39.33 Radiation detection instruments. (a) The licensee shall keep a calibrated and operable...

  19. Variability in Accreditation Council for Graduate Medical Education Resident Case Log System practices among orthopaedic surgery residents.

    PubMed

    Salazar, Dane; Schiff, Adam; Mitchell, Erika; Hopkinson, William

    2014-02-05

    The Accreditation Council for Graduate Medical Education (ACGME) Resident Case Log System is designed to be a reflection of residents' operative volume and an objective measure of their surgical experience. All operative procedures and manipulations in the operating room, Emergency Department, and outpatient clinic are to be logged into the Resident Case Log System. Discrepancies in the log volumes between residents and residency programs often prompt scrutiny. However, it remains unclear if such disparities truly represent differences in operative experiences or if they are reflections of inconsistent logging practices. The purpose of this study was to investigate individual recording practices among orthopaedic surgery residents prior to August 1, 2011. Orthopaedic surgery residents received a questionnaire on case log practices that was distributed through the Council of Orthopaedic Residency Directors list server. Respondents were asked to respond anonymously about recording practices in different clinical settings as well as types of cases routinely logged. Hypothetical scenarios of common orthopaedic procedures were presented to investigate the differences in the Current Procedural Terminology codes utilized. Two hundred and ninety-eight orthopaedic surgery residents completed the questionnaire; 37% were fifth-year residents, 22% were fourth-year residents, 18% were third-year residents, 15% were second-year residents, and 8% were first-year residents. Fifty-six percent of respondents reported routinely logging procedures performed in the Emergency Department or urgent care setting. Twenty-two percent of participants routinely logged procedures in the clinic or outpatient setting, 20% logged joint injections, and only 13% logged casts or splints applied in the office setting. There was substantial variability in the Current Procedural Terminology codes selected for the seven clinical scenarios. There has been a lack of standardization in case-logging practices among orthopaedic surgery residents prior to August 1, 2011. ACGME case log data prior to this date may not be a reliable measure of residents' procedural experience.

  20. A simulation-based approach for evaluating logging residue handling systems.

    Treesearch

    B. Bruce Bare; Benjamin A. Jayne; Brian F. Anholt

    1976-01-01

    Describes a computer simulation model for evaluating logging residue handling systems. The flow of resources is traced through a prespecified combination of operations including yarding, chipping, sorting, loading, transporting, and unloading. The model was used to evaluate the feasibility of converting logging residues to chips that could be used, for example, to...

  1. Robust Spatial Autoregressive Modeling for Hardwood Log Inspection

    Treesearch

    Dongping Zhu; A.A. Beex

    1994-01-01

    We explore the application of a stochastic texture modeling method toward a machine vision system for log inspection in the forest products industry. This machine vision system uses computerized tomography (CT) imaging to locate and identify internal defects in hardwood logs. The application of CT to such industrial vision problems requires efficient and robust image...

  2. Prevalence of pathogenic bacteria in street vended ready-to-eat meats in Windhoek, Namibia.

    PubMed

    Shiningeni, Daphney; Chimwamurombe, Percy; Shilangale, Renatus; Misihairabgwi, Jane

    2018-05-31

    To determine the prevalence of pathogenic bacteria in street vended ready-to-eat meats in Windhoek, Namibia, a total of 96 street vended ready to eat meat samples were evaluated. Prevalences of 42%, 52%, 15%, 6% and 83% were observed for Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, Shigella and Enterobacteriaceae respectively, while the highest aerobic plate counts were 7.74 Log 10 cfu/g, 5.67 Log 10 cfu/g, 5.12 Log 10 cfu/g , 4.56 Log 10 cfu/g, 3.3 Log 10 cfu/g, 5.75 Log 10 cfu/g respectively. Unsatisfactory microbial levels were 32% for aerobic plate count, 26% for Enterobacteriaceae, 35% for Escherichia coli, 11% for Listeria monocytogenes, 7% for Staphylococcus aureus and 6% for Shigella. Salmonella was detected in 11% and 40% of samples from two suburbs. The unsatisfactory microbiological quality of some ready-to-eat meats necessitates the provision of training on food safety and hygiene to street vendors for consumer protection. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Quantification of HER2/neu gene amplification by competitive pcr using fluorescent melting curve analysis.

    PubMed

    Lyon, E; Millson, A; Lowery, M C; Woods, R; Wittwer, C T

    2001-05-01

    Molecular detection methods for HER2/neu gene amplification include fluorescence in situ hybridization (FISH) and competitive PCR. We designed a quantitative PCR system utilizing fluorescent hybridization probes and a competitor that differed from the HER2/neu sequence by a single base change. Increasing twofold concentrations of competitor were coamplified with DNA from cell lines with various HER2/neu copy numbers at the HER2/neu locus. Competitor DNA was distinguished from the HER2/neu sequence by a fluorescent hybridization probe and melting curve analysis on a fluorescence-monitoring thermal cycler. The percentages of competitor to target peak areas on derivative fluorescence vs temperature curves were used to calculate copy number. Real-time monitoring of the PCR reaction showed comparable relative areas throughout the log phase and during the PCR plateau, indicating that only end-point detection is necessary. The dynamic range was over two logs (2000-250 000 competitor copies) with CVs < 20%. Three cell lines (MRC-5, T-47D, and SK-BR-3) were determined to have gene doses of 1, 3, and 11, respectively. Gene amplification was detected in 3 of 13 tumor samples and was correlated with conventional real-time PCR and FISH analysis. Use of relative peak areas allows gene copy numbers to be quantified against an internal competitive control in < 1 h.

  4. Frequency-agile wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Arms, Steven W.; Townsend, Christopher P.; Churchill, David L.; Hamel, Michael J.; Galbreath, Jacob H.; Mundell, Steven W.

    2004-07-01

    Our goal was to demonstrate a wireless communications system capable of simultaneous, high speed data communications from a variety of sensors. We have previously reported on the design and application of 2 KHz data logging transceiver nodes, however, only one node may stream data at a time, since all nodes on the network use the same communications frequency. To overcome these limitations, second generation data logging transceivers were developed with software programmable radio frequency (RF) communications. Each node contains on-board memory (2 Mbytes), sensor excitation, instrumentation amplifiers with programmable gains & offsets, multiplexer, 16 bit A/D converter, microcontroller, and frequency agile, bi-directional, frequency shift keyed (FSK) RF serial data link. These systems are capable of continuous data transmission from 26 distinct nodes (902-928 MHz band, 75 kbaud). The system was demonstrated in a compelling structural monitoring application. The National Parks Service requested a means for continual monitoring and recording of sensor data from the Liberty Bell during a move to a new location (Philadelphia, October 2003). Three distinct, frequency agile, wireless sensing nodes were used to detect visible crack shear/opening micromotions, triaxial accelerations, and hairline crack tip strains. The wireless sensors proved to be useful in protecting the Liberty Bell.

  5. Detection of hepatitis C virus RNA in saliva of patients with active infection not associated with periodontal or liver disease severity

    PubMed Central

    2014-01-01

    Background Hepatitis C virus (HCV) is mainly transmitted by parenteral route, being blood transfusion and intravenous drug use the most frequent risk factors. However, it has been suggested that there are other routes of transmission. There are several studies where HCV RNA has been detected in saliva of patients infected with HCV, and epidemiological studies have proposed the dental treatments as possible risk factors for HCV transmission. The purpose of this study was to detect the presence of HCV RNA in saliva of patients with active infection and associating with periodontal or liver disease. Methods Patients with quantifiable HCV-RNA in serum were enrolled in the study. Periodontal disease was assessed using the modified gingival index (MGI). Presence of dental plaque was assessed with the use of disclosing tablets. Patients were clinically and laboratory evaluated to identify the stage of liver disease, the HCV RNA was determinate in saliva by nested RT-PCR. To determine associations between different parameters univariate and multivariate analysis were used. Results A total of 45 patients were included. Of these patients, 21 (46.6%) had hepatitis, 23 (51.1%) had cirrhosis and one patient (2.4%) presented hepatocellular carcinoma (HCC). Viral loads in serum ranged from 2.31–6.68 log IU/ml with a mean of 5.46 log IU/ml (95% CI 5.23–5.70). HCV RNA was positive in saliva of 29 patients (64.4%) and was not detected in 16 (35.6%). For univariate analysis three independent variables were associated with the detection of HCV-RNA in saliva: gender, viral load and dental plaque and multivariate analysis only one independent variable viral load >5.17 log IU/mL remained significantly associated with the detection of HCV in saliva (p = 0.0002). A statistical difference was observed when viral load was analyzed, log 5.85 IU/mL (95% CI 5.67–6.02) for patients with HCV in saliva vs. log 4.77 IU/mL (95% CI 4.35–5.19) for patients without HCV in saliva (p = 0.0001). The detection of HCV-RNA in saliva was more frequent in patients with relatively high serum viral loads. Conclusion HCV-RNA in saliva was associated with the level of serum viral load but not with periodontal or liver disease severity. PMID:24512371

  6. Robust 3D DFT video watermarking

    NASA Astrophysics Data System (ADS)

    Deguillaume, Frederic; Csurka, Gabriela; O'Ruanaidh, Joseph J.; Pun, Thierry

    1999-04-01

    This paper proposes a new approach for digital watermarking and secure copyright protection of videos, the principal aim being to discourage illicit copying and distribution of copyrighted material. The method presented here is based on the discrete Fourier transform (DFT) of three dimensional chunks of video scene, in contrast with previous works on video watermarking where each video frame was marked separately, or where only intra-frame or motion compensation parameters were marked in MPEG compressed videos. Two kinds of information are hidden in the video: a watermark and a template. Both are encoded using an owner key to ensure the system security and are embedded in the 3D DFT magnitude of video chunks. The watermark is a copyright information encoded in the form of a spread spectrum signal. The template is a key based grid and is used to detect and invert the effect of frame-rate changes, aspect-ratio modification and rescaling of frames. The template search and matching is performed in the log-log-log map of the 3D DFT magnitude. The performance of the presented technique is evaluated experimentally and compared with a frame-by-frame 2D DFT watermarking approach.

  7. Radio-frequency heating to inactivate Salmonella Typhimurium and Escherichia coli O157:H7 on black and red pepper spice.

    PubMed

    Kim, Sung-Youn; Sagong, Hun-Gu; Choi, Sang Ho; Ryu, Sangryeol; Kang, Dong-Hyun

    2012-02-01

    The efficacy of radio-frequency (RF) heating to inactivate Salmonella Typhimurium and Escherichia coli O157:H7 on black and red pepper spice was investigated. A 27.12 MHz RF heating system consisted of two parallel-plate electrodes was used, with the sample being placed between them. Black peppers (whole and ground) and red peppers (+ 16 mesh, -16 + 25 mesh, and -25 mesh) inoculated with S. Typhimurium and E. coli O157:H7 were treated with RF energy during 50s for black peppers and 40s for red peppers, and color change of samples was evaluated after treatment. RF heating for 50s resulted in 2.80 to 4.29 log CFU/g reductions of S. Typhimurium and E. coli O157:H7 in black peppers and RF heating of red peppers for 40s reduced pathogens by 3.38 log CFU/g to more than 5 log CFU/g (below the detection limit) without affecting the color quality change. The results suggest that RF heating has the potential for novel thermal process to control foodborne pathogens in spice. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Overestimation of the Legionella spp. load in environmental samples by quantitative real-time PCR: pretreatment with propidium monoazide as a tool for the assessment of an association between Legionella concentration and sanitary risk.

    PubMed

    Ditommaso, Savina; Ricciardi, Elisa; Giacomuzzi, Monica; Arauco Rivera, Susan R; Ceccarelli, Adriano; Zotti, Carla M

    2014-12-01

    Quantitative polymerase chain reaction (qPCR) offers rapid, sensitive, and specific detection of Legionella in environmental water samples. In this study, qPCR and qPCR combined with propidium monoazide (PMA-qPCR) were both applied to hot-water system samples and compared to traditional culture techniques. In addition, we evaluated the ability of PMA-qPCR to monitor the efficacy of different disinfection strategies. Comparison between the quantification obtained by culture and by qPCR or PMA-qPCR on environmental water samples confirms that the concentration of Legionella estimated by GU/L is generally higher than that estimated in CFU/L. Our results on 57 hot-water-system samples collected from 3 different sites show that: i) qPCR results were on average 178-fold higher than the culture results (Δ log10=2.25), ii) PMA-qPCR results were on average 27-fold higher than the culture results (Δ log10=1.43), iii) propidium monoazide-induced signal reduction in qPCR were nearly 10-fold (Δ log10=0.95), and that iv) different degrees of correlations between the 3 methods might be explained by different matrix properties, but also by different disinfection methods affecting cultivability of Legionella. In our study, we calculated the logarithmic differences between the results obtained by PMA-qPCR and those obtained by culture, and we suggested an algorithm for the interpretation of PMA-qPCR results for the routine monitoring of healthcare water systems using a commercial qPCR system (iQ-check real-time PCR kit; Bio-Rad, Marnes-la-Coquette, France). Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Towards a geospatial wikipedia

    NASA Astrophysics Data System (ADS)

    Fritz, S.; McCallum, I.; Schill, C.; Perger, C.; Kraxner, F.; Obersteiner, M.

    2009-04-01

    Based on the Google Earth (http://earth.google.com) platform we have developed a geospatial Wikipedia (geo-wiki.org). The tool allows everybody in the world to contribute to spatial validation and is made available to the internet community interested in that task. We illustrate how this tool can be used for different applications. In our first application we combine uncertainty hotspot information from three global land cover datasets (GLC, MODIS, GlobCover). With an ever increasing amount of high resolution images available on Google Earth, it is becoming increasingly possible to distinguish land cover features with a high degree of accuracy. We first direct the land cover validation community to certain hotspots of land cover uncertainty and then ask them to fill in a small popup menu on type of land cover, possibly a picture at that location with the different cardinal points as well as date and what type of validation was chosen (google earth imagery/panoramio or if the person has ground truth data). We have implemented the tool via a land cover validation community at FACEBOOK which is based on a snowball system which allows the tracking of individuals and the possibility to ignore users which misuse the system. In a second application we illustrate how the tool could possibly be used for mapping malaria occurrence and small water bodies as well as overall malaria risk. For this application we have implemented a polygon as well as attribute function using Google maps as along with virtual earth using openlayers. The third application deals with illegal logging and how an alert system for illegal logging detection within a certain land tenure system could be implemented. Here we show how the tool can be used to document illegal logging via a YouTube video.

  10. Role of Large Clinical Datasets From Physiologic Monitors in Improving the Safety of Clinical Alarm Systems and Methodological Considerations: A Case From Philips Monitors.

    PubMed

    Sowan, Azizeh Khaled; Reed, Charles Calhoun; Staggers, Nancy

    2016-09-30

    Large datasets of the audit log of modern physiologic monitoring devices have rarely been used for predictive modeling, capturing unsafe practices, or guiding initiatives on alarm systems safety. This paper (1) describes a large clinical dataset using the audit log of the physiologic monitors, (2) discusses benefits and challenges of using the audit log in identifying the most important alarm signals and improving the safety of clinical alarm systems, and (3) provides suggestions for presenting alarm data and improving the audit log of the physiologic monitors. At a 20-bed transplant cardiac intensive care unit, alarm data recorded via the audit log of bedside monitors were retrieved from the server of the central station monitor. Benefits of the audit log are many. They include easily retrievable data at no cost, complete alarm records, easy capture of inconsistent and unsafe practices, and easy identification of bedside monitors missed from a unit change of alarm settings adjustments. Challenges in analyzing the audit log are related to the time-consuming processes of data cleaning and analysis, and limited storage and retrieval capabilities of the monitors. The audit log is a function of current capabilities of the physiologic monitoring systems, monitor's configuration, and alarm management practices by clinicians. Despite current challenges in data retrieval and analysis, large digitalized clinical datasets hold great promise in performance, safety, and quality improvement. Vendors, clinicians, researchers, and professional organizations should work closely to identify the most useful format and type of clinical data to expand medical devices' log capacity.

  11. Constraining the H2 column density distribution at z ˜ 3 from composite DLA spectra

    NASA Astrophysics Data System (ADS)

    Balashev, S. A.; Noterdaeme, P.

    2018-07-01

    We present the detection of the average H2 absorption signal in the overall population of neutral gas absorption systems at z˜ 3 using composite absorption spectra built from the Sloan Digital Sky Survey-III damped Lyman α catalogue. We present a new technique to directly measure the H2 column density distribution function f_H_2(N) from the average H2 absorption signal. Assuming a power-law column density distribution, we obtain a slope β = -1.29 ± 0.06(stat) ± 0.10 (sys) and an incidence rate of strong H2 absorptions [with N(H2) ≳ 1018 cm-2] to be 4.0 ± 0.5(stat) ± 1.0 (sys) per cent in H I absorption systems with N(H I) ≥1020 cm-2. Assuming the same inflexion point where f_H_2(N) steepens as at z = 0, we estimate that the cosmological density of H2 in the column density range log N(H_2) (cm^{-2})= 18{-}22 is {˜ } 15 per cent of the total. We find one order of magnitude higher H2 incident rate in a sub-sample of extremely strong damped Lyman α absorption systems (DLAs) [log N(H I) (cm^{-2}) ≥ 21.7], which, together with the derived shape of f_H_2(N), suggests that the typical H I-H2 transition column density in DLAs is log N(H)(cm-2) ≳ 22.3 in agreement with theoretical expectations for the average (low) metallicity of DLAs at high-z.

  12. Pathogen inactivation efficacy of Mirasol PRT System and Intercept Blood System for non-leucoreduced platelet-rich plasma-derived platelets suspended in plasma.

    PubMed

    Kwon, S Y; Kim, I S; Bae, J E; Kang, J W; Cho, Y J; Cho, N S; Lee, S W

    2014-10-01

    This study was conducted to evaluate the efficacy of pathogen inactivation (PI) in non-leucoreduced platelet-rich plasma-derived platelets suspended in plasma using the Mirasol PRT System and the Intercept Blood System. Platelets were pooled using the Acrodose PL system and separated into two aliquots for Mirasol and Intercept treatment. Four replicates of each viral strain were used for the evaluation. For bacteria, both low-titre (45-152 CFU/unit) inoculation and high-titre (7·34-10·18 log CFU/unit) inoculation with two replicates for each bacterial strain were used. Platelets with non-detectable bacterial growth and platelets inoculated with a low titre were stored for 5 days, and culture was performed with the BacT/ALERT system. The inactivation efficacy expressed as log reduction for Mirasol and Intercept systems for viruses was as follows: human immunodeficiency virus 1, ≥4·19 vs. ≥4·23; bovine viral diarrhoea virus, 1·83 vs. ≥6·03; pseudorabies virus, 2·73 vs. ≥5·20; hepatitis A virus, 0·62 vs. 0·76; and porcine parvovirus, 0·28 vs. 0·38. The inactivation efficacy for bacteria was as follows: Escherichia coli, 5·45 vs. ≥9·22; Staphylococcus aureus, 4·26 vs. ≥10·11; and Bacillus subtilis, 5·09 vs. ≥7·74. Postinactivation bacterial growth in platelets inoculated with a low titre of S. aureus or B. subtilis was detected only with Mirasol. Pathogen inactivation efficacy of Intercept for enveloped viruses was found to be satisfactory. Mirasol showed satisfactory inactivation efficacy for HIV-1 only. The two selected non-enveloped viruses were not inactivated by both systems. Inactivation efficacy of Intercept was more robust for all bacteria tested at high or low titres. © 2014 International Society of Blood Transfusion.

  13. SU-C-BRD-03: Analysis of Accelerator Generated Text Logs for Preemptive Maintenance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Able, CM; Baydush, AH; Nguyen, C

    2014-06-15

    Purpose: To develop a model to analyze medical accelerator generated parameter and performance data that will provide an early warning of performance degradation and impending component failure. Methods: A robust 6 MV VMAT quality assurance treatment delivery was used to test the constancy of accelerator performance. The generated text log files were decoded and analyzed using statistical process control (SPC) methodology. The text file data is a single snapshot of energy specific and overall systems parameters. A total of 36 system parameters were monitored which include RF generation, electron gun control, energy control, beam uniformity control, DC voltage generation, andmore » cooling systems. The parameters were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and the parameter/system specification. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: the value of 1 standard deviation from the mean operating parameter of 483 TB systems, a small fraction (≤ 5%) of the operating range, or a fraction of the minor fault deviation. Results: There were 34 parameters in which synthetic errors were introduced. There were 2 parameters (radial position steering coil, and positive 24V DC) in which the errors did not exceed the limit of the I/MR chart. The I chart limit was exceeded for all of the remaining parameters (94.2%). The MR chart limit was exceeded in 29 of the 32 parameters (85.3%) in which the I chart limit was exceeded. Conclusion: Statistical process control I/MR evaluation of text log file parameters may be effective in providing an early warning of performance degradation or component failure for digital medical accelerator systems. Research is Supported by Varian Medical Systems, Inc.« less

  14. Structural Acoustic UXO Detection and Identification in Marine Environments - Interim Report for SERDP MR-2103 Follow-On

    DTIC Science & Technology

    2015-07-30

    into the image processing algorithm the AUV position data available from the Doppler Velocity Log (DVL) and Inertial Measurement Unit ( IMU ) systems...uncertainty due to unknown sensor z coordinates. We considered both AUV altitude and roll but not pitch which we assumed to have a small effect on the...buried target. Taken together, the images suggest that the block is buried horizontally but rolled along its long axis ~80° such that the exposed large

  15. Bacteriophage cocktail significantly reduces or eliminates Listeria monocytogenes contamination on lettuce, apples, cheese, smoked salmon and frozen foods.

    PubMed

    Perera, Meenu N; Abuladze, Tamar; Li, Manrong; Woolston, Joelle; Sulakvelidze, Alexander

    2015-12-01

    ListShield™, a commercially available bacteriophage cocktail that specifically targets Listeria monocytogenes, was evaluated as a bio-control agent for L. monocytogenes in various Ready-To-Eat foods. ListShield™ treatment of experimentally contaminated lettuce, cheese, smoked salmon, and frozen entrèes significantly reduced (p < 0.05) L. monocytogenes contamination by 91% (1.1 log), 82% (0.7 log), 90% (1.0 log), and 99% (2.2 log), respectively. ListShield™ application, alone or combined with an antioxidant/anti-browning solution, resulted in a statistically significant (p < 0.001) 93% (1.1 log) reduction of L. monocytogenes contamination on apple slices after 24 h at 4 °C. Treatment of smoked salmon from a commercial processing facility with ListShield™ eliminated L. monocytogenes (no detectable L. monocytogenes) in both the naturally contaminated and experimentally contaminated salmon fillets. The organoleptic quality of foods was not affected by application of ListShield™, as no differences in the color, taste, or appearance were detectable. Bio-control of L. monocytogenes with lytic bacteriophage preparations such as ListShield™ can offer an environmentally-friendly, green approach for reducing the risk of listeriosis associated with the consumption of various foods that may be contaminated with L. monocytogenes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Operating Ferret on a patrol boat

    NASA Astrophysics Data System (ADS)

    Bédard, Jacques

    2006-05-01

    Ferret is an acoustic system that detects, recognizes and localizes the source and direction of small arms fire. The system comprises a small array of microphones and pressure sensors connected to a standard PC-104 computer that analyzes, displays, reports and logs the parameters of a recognized shot. The system operates by detecting and recognizing the ballistic shock waves created by the supersonic bullet, combined with the muzzle blast wave propagating from the weapon. The system was recently installed and tested on a patrol boat operated by the Royal Canadian Mounted Police (RCMP). An electronic compass with tilt compensation and a GPS was incorporated into the system. This allows the system to correct for the motion of the boat and provide the full coordinates of the shooter. The system also updates the azimuth to the shooter in real time as the boat turns. This paper presents the results of our test and evaluation based on a live firing experiment. Ferret is the result of a collaborative effort by Defence R&D Canada and MacDonald Dettwiler and Associates.

  17. LANDMARK-BASED SPEECH RECOGNITION: REPORT OF THE 2004 JOHNS HOPKINS SUMMER WORKSHOP.

    PubMed

    Hasegawa-Johnson, Mark; Baker, James; Borys, Sarah; Chen, Ken; Coogan, Emily; Greenberg, Steven; Juneja, Amit; Kirchhoff, Katrin; Livescu, Karen; Mohan, Srividya; Muller, Jennifer; Sonmez, Kemal; Wang, Tianyu

    2005-01-01

    Three research prototype speech recognition systems are described, all of which use recently developed methods from artificial intelligence (specifically support vector machines, dynamic Bayesian networks, and maximum entropy classification) in order to implement, in the form of an automatic speech recognizer, current theories of human speech perception and phonology (specifically landmark-based speech perception, nonlinear phonology, and articulatory phonology). All three systems begin with a high-dimensional multiframe acoustic-to-distinctive feature transformation, implemented using support vector machines trained to detect and classify acoustic phonetic landmarks. Distinctive feature probabilities estimated by the support vector machines are then integrated using one of three pronunciation models: a dynamic programming algorithm that assumes canonical pronunciation of each word, a dynamic Bayesian network implementation of articulatory phonology, or a discriminative pronunciation model trained using the methods of maximum entropy classification. Log probability scores computed by these models are then combined, using log-linear combination, with other word scores available in the lattice output of a first-pass recognizer, and the resulting combination score is used to compute a second-pass speech recognition output.

  18. A preliminary scheme to modify the reception characteristics of a log-periodic antenna within its operating bandwidth

    NASA Astrophysics Data System (ADS)

    Kishore, P.; Kathiravan, C.

    The level of radio emission from the Sun and other celestial sources that we receive on the Earth is very low when compared to those generated here (e.g. by TV and radio broadcasting stations, engines of automobiles and industrial equipment). Therefore, it requires technically advanced systems to detect those weak emissions in order to study their characteristics, generation mechanisms, etc. - one of the interests of human race to enhance its knowledge about space and its entities. Although inevitable and became part of life, the civilian radio broadcast, communication networks are capable of affecting such observations directly. Studies show that eliminating such interferences at an early stage improves not only the analyses but also the reliability of the results. Towards this an attempt is made to alter the characteristics of an antenna since it is the foremost component of any radio receiver system. The tests are made with a Log-periodic dipole antenna (LPDA) and the changes in the reception characteristics over a few set of undesired frequency bands are discussed here.

  19. Analysis of web-related threats in ten years of logs from a scientific portal

    NASA Astrophysics Data System (ADS)

    Santos, Rafael D. C.; Grégio, André R. A.; Raddick, Jordan; Vattki, Vamsi; Szalay, Alex

    2012-06-01

    SkyServer is an Internet portal to data from the Sloan Digital Sky Survey, the largest online archive of astronomy data in the world. provides free access to hundreds of millions of celestial objects for science, education and outreach purposes. Logs of accesses to SkyServer comprise around 930 million hits, 140 million web services accesses and 170 million SQL submitted queries, collected over the past 10 years. These logs also contain indications of compromise attempts on the servers. In this paper, we show some threats that were detected in ten years of stored logs, and compare them with known threats in those years. Also, we present an analysis of the evolution of those threats over these years.

  20. A depth video sensor-based life-logging human activity recognition system for elderly care in smart indoor environments.

    PubMed

    Jalal, Ahmad; Kamal, Shaharyar; Kim, Daijin

    2014-07-02

    Recent advancements in depth video sensors technologies have made human activity recognition (HAR) realizable for elderly monitoring applications. Although conventional HAR utilizes RGB video sensors, HAR could be greatly improved with depth video sensors which produce depth or distance information. In this paper, a depth-based life logging HAR system is designed to recognize the daily activities of elderly people and turn these environments into an intelligent living space. Initially, a depth imaging sensor is used to capture depth silhouettes. Based on these silhouettes, human skeletons with joint information are produced which are further used for activity recognition and generating their life logs. The life-logging system is divided into two processes. Firstly, the training system includes data collection using a depth camera, feature extraction and training for each activity via Hidden Markov Models. Secondly, after training, the recognition engine starts to recognize the learned activities and produces life logs. The system was evaluated using life logging features against principal component and independent component features and achieved satisfactory recognition rates against the conventional approaches. Experiments conducted on the smart indoor activity datasets and the MSRDailyActivity3D dataset show promising results. The proposed system is directly applicable to any elderly monitoring system, such as monitoring healthcare problems for elderly people, or examining the indoor activities of people at home, office or hospital.

  1. A Depth Video Sensor-Based Life-Logging Human Activity Recognition System for Elderly Care in Smart Indoor Environments

    PubMed Central

    Jalal, Ahmad; Kamal, Shaharyar; Kim, Daijin

    2014-01-01

    Recent advancements in depth video sensors technologies have made human activity recognition (HAR) realizable for elderly monitoring applications. Although conventional HAR utilizes RGB video sensors, HAR could be greatly improved with depth video sensors which produce depth or distance information. In this paper, a depth-based life logging HAR system is designed to recognize the daily activities of elderly people and turn these environments into an intelligent living space. Initially, a depth imaging sensor is used to capture depth silhouettes. Based on these silhouettes, human skeletons with joint information are produced which are further used for activity recognition and generating their life logs. The life-logging system is divided into two processes. Firstly, the training system includes data collection using a depth camera, feature extraction and training for each activity via Hidden Markov Models. Secondly, after training, the recognition engine starts to recognize the learned activities and produces life logs. The system was evaluated using life logging features against principal component and independent component features and achieved satisfactory recognition rates against the conventional approaches. Experiments conducted on the smart indoor activity datasets and the MSRDailyActivity3D dataset show promising results. The proposed system is directly applicable to any elderly monitoring system, such as monitoring healthcare problems for elderly people, or examining the indoor activities of people at home, office or hospital. PMID:24991942

  2. Electrical detection of liquid lithium leaks from pipe joints.

    PubMed

    Schwartz, J A; Jaworski, M A; Mehl, J; Kaita, R; Mozulay, R

    2014-11-01

    A test stand for flowing liquid lithium is under construction at Princeton Plasma Physics Laboratory. As liquid lithium reacts with atmospheric gases and water, an electrical interlock system for detecting leaks and safely shutting down the apparatus has been constructed. A defense in depth strategy is taken to minimize the risk and impact of potential leaks. Each demountable joint is diagnosed with a cylindrical copper shell electrically isolated from the loop. By monitoring the electrical resistance between the pipe and the copper shell, a leak of (conductive) liquid lithium can be detected. Any resistance of less than 2 kΩ trips a relay, shutting off power to the heaters and pump. The system has been successfully tested with liquid gallium as a surrogate liquid metal. The circuit features an extensible number of channels to allow for future expansion of the loop. To ease diagnosis of faults, the status of each channel is shown with an analog front panel LED, and monitored and logged digitally by LabVIEW.

  3. Log-Log Convexity of Type-Token Growth in Zipf's Systems

    NASA Astrophysics Data System (ADS)

    Font-Clos, Francesc; Corral, Álvaro

    2015-06-01

    It is traditionally assumed that Zipf's law implies the power-law growth of the number of different elements with the total number of elements in a system—the so-called Heaps' law. We show that a careful definition of Zipf's law leads to the violation of Heaps' law in random systems, with growth curves that have a convex shape in log-log scale. These curves fulfill universal data collapse that only depends on the value of Zipf's exponent. We observe that real books behave very much in the same way as random systems, despite the presence of burstiness in word occurrence. We advance an explanation for this unexpected correspondence.

  4. Performance analysis of MIMO wireless optical communication system with Q-ary PPM over correlated log-normal fading channel

    NASA Astrophysics Data System (ADS)

    Wang, Huiqin; Wang, Xue; Lynette, Kibe; Cao, Minghua

    2018-06-01

    The performance of multiple-input multiple-output wireless optical communication systems that adopt Q-ary pulse position modulation over spatial correlated log-normal fading channel is analyzed in terms of its un-coded bit error rate and ergodic channel capacity. The analysis is based on the Wilkinson's method which approximates the distribution of a sum of correlated log-normal random variables to a log-normal random variable. The analytical and simulation results corroborate the increment of correlation coefficients among sub-channels lead to system performance degradation. Moreover, the receiver diversity has better performance in resistance of spatial correlation caused channel fading.

  5. A complete X-ray sample of the high latitude sky from HEAO-1 A-2: log N lo S and luminosity functions

    NASA Technical Reports Server (NTRS)

    Piccinotti, G.; Mushotzky, R. F.; Boldt, E. A.; Holt, S. S.; Marshall, F. E.; Serlemitsos, P. J.; Shafer, R. A.

    1981-01-01

    An experiment was performed in which a complete X-ray survey of the 8.2 steradians of the sky at galactic latitudes where the absolute value of b is 20 deg down to a limiting sensitivity of 3.1 x ten to the minus 11th power ergs/sq cm sec in the 2-10 keV band. Of the 85 detected sources 17 were identified with galactic objects, 61 were identified with extragalactic objects, and 7 remain unidentified. The log N - log S relation for the non-galactic objects is well fit by the Euclidean relationship. The X-ray spectra of these objects were used to construct log N - log S in physical units. The complete sample of identified sources was used to construct X-ray luminosity functions, using the absolute maximum likelihood method, for clusters galaxies and active galactic nuclei.

  6. Differential resistance of drinking water bacterial populations to monochloramine disinfection.

    PubMed

    Chiao, Tzu-Hsin; Clancy, Tara M; Pinto, Ameet; Xi, Chuanwu; Raskin, Lutgarde

    2014-04-01

    The impact of monochloramine disinfection on the complex bacterial community structure in drinking water systems was investigated using culture-dependent and culture-independent methods. Changes in viable bacterial diversity were monitored using culture-independent methods that distinguish between live and dead cells based on membrane integrity, providing a highly conservative measure of viability. Samples were collected from lab-scale and full-scale drinking water filters exposed to monochloramine for a range of contact times. Culture-independent detection of live cells was based on propidium monoazide (PMA) treatment to selectively remove DNA from membrane-compromised cells. Quantitative PCR (qPCR) and pyrosequencing of 16S rRNA genes was used to quantify the DNA of live bacteria and characterize the bacterial communities, respectively. The inactivation rate determined by the culture-independent PMA-qPCR method (1.5-log removal at 664 mg·min/L) was lower than the inactivation rate measured by the culture-based methods (4-log removal at 66 mg·min/L). Moreover, drastic changes in the live bacterial community structure were detected during monochloramine disinfection using PMA-pyrosequencing, while the community structure appeared to remain stable when pyrosequencing was performed on samples that were not subject to PMA treatment. Genera that increased in relative abundance during monochloramine treatment include Legionella, Escherichia, and Geobacter in the lab-scale system and Mycobacterium, Sphingomonas, and Coxiella in the full-scale system. These results demonstrate that bacterial populations in drinking water exhibit differential resistance to monochloramine, and that the disinfection process selects for resistant bacterial populations.

  7. Ubiquitous Learning Project Using Life-Logging Technology in Japan

    ERIC Educational Resources Information Center

    Ogata, Hiroaki; Hou, Bin; Li, Mengmeng; Uosaki, Noriko; Mouri, Kosuke; Liu, Songran

    2014-01-01

    A Ubiquitous Learning Log (ULL) is defined as a digital record of what a learner has learned in daily life using ubiquitous computing technologies. In this paper, a project which developed a system called SCROLL (System for Capturing and Reusing Of Learning Log) is presented. The aim of developing SCROLL is to help learners record, organize,…

  8. Geometric Verification of Dynamic Wave Arc Delivery With the Vero System Using Orthogonal X-ray Fluoroscopic Imaging.

    PubMed

    Burghelea, Manuela; Verellen, Dirk; Poels, Kenneth; Gevaert, Thierry; Depuydt, Tom; Tournel, Koen; Hung, Cecilia; Simon, Viorica; Hiraoka, Masahiro; de Ridder, Mark

    2015-07-15

    The purpose of this study was to define an independent verification method based on on-board orthogonal fluoroscopy to determine the geometric accuracy of synchronized gantry-ring (G/R) rotations during dynamic wave arc (DWA) delivery available on the Vero system. A verification method for DWA was developed to calculate O-ring-gantry (G/R) positional information from ball-bearing positions retrieved from fluoroscopic images of a cubic phantom acquired during DWA delivery. Different noncoplanar trajectories were generated in order to investigate the influence of path complexity on delivery accuracy. The G/R positions detected from the fluoroscopy images (DetPositions) were benchmarked against the G/R angulations retrieved from the control points (CP) of the DWA RT plan and the DWA log files recorded by the treatment console during DWA delivery (LogActed). The G/R rotational accuracy was quantified as the mean absolute deviation ± standard deviation. The maximum G/R absolute deviation was calculated as the maximum 3-dimensional distance between the CP and the closest DetPositions. In the CP versus DetPositions comparison, an overall mean G/R deviation of 0.13°/0.16° ± 0.16°/0.16° was obtained, with a maximum G/R deviation of 0.6°/0.2°. For the LogActed versus DetPositions evaluation, the overall mean deviation was 0.08°/0.15° ± 0.10°/0.10° with a maximum G/R of 0.3°/0.4°. The largest decoupled deviations registered for gantry and ring were 0.6° and 0.4° respectively. No directional dependence was observed between clockwise and counterclockwise rotations. Doubling the dose resulted in a double number of detected points around each CP, and an angular deviation reduction in all cases. An independent geometric quality assurance approach was developed for DWA delivery verification and was successfully applied on diverse trajectories. Results showed that the Vero system is capable of following complex G/R trajectories with maximum deviations during DWA below 0.6°. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Galaxy evolution by color-log(n) type since redshift unity in the Hubble Ultra Deep Field

    NASA Astrophysics Data System (ADS)

    Cameron, E.; Driver, S. P.

    2009-01-01

    Aims: We explore the use of the color-log(n) (where n is the global Sérsic index) plane as a tool for subdividing the galaxy population in a physically-motivated manner out to redshift unity. We thereby aim to quantify surface brightness evolution by color-log(n) type, accounting separately for the specific selection and measurement biases against each. Methods: We construct (u-r) color-log(n) diagrams for distant galaxies in the Hubble Ultra Deep Field (UDF) within a series of volume-limited samples to z=1.5. The color-log(n) distributions of these high redshift galaxies are compared against that measured for nearby galaxies in the Millennium Galaxy Catalogue (MGC), as well as to the results of visual morphological classification. Based on this analysis we divide our sample into three color-structure classes. Namely, “red, compact”, “blue, diffuse” and “blue, compact”. Luminosity-size diagrams are constructed for members of the two largest classes (“red, compact” and “blue, diffuse”), both in the UDF and the MGC. Artificial galaxy simulations (for systems with exponential and de Vaucouleurs profile shapes alternately) are used to identify “bias-free” regions of the luminosity-size plane in which galaxies are detected with high completeness, and their fluxes and sizes recovered with minimal surface brightness-dependent biases. Galaxy evolution is quantified via comparison of the low and high redshift luminosity-size relations within these “bias-free” regions. Results: We confirm the correlation between color-log(n) plane position and visual morphological type observed locally and in other high redshift studies in the color and/or structure domain. The combined effects of observational uncertainties, the morphological K-correction and cosmic variance preclude a robust statistical comparison of the shape of the MGC and UDF color-log(n) distributions. However, in the interval 0.75 < z <1.0 where the UDF i-band samples close to rest-frame B-band light (i.e., the morphological K-correction between our samples is negligible) we are able to present tentative evidence of bimodality, albiet for a very small sample size (17 galaxies). Our unique approach to quantifying selection and measurement biases in the luminosity-size plane highlights the need to consider errors in the recovery of both magnitudes and sizes, and their dependence on profile shape. Motivated by these results we divide our sample into the three color-structure classes mentioned above and quantify luminosity-size evolution by galaxy type. Specifically, we detect decreases in B-band, surface brightness of 1.57 ± 0.22 mag arcsec-2 and 1.65 ± 0.22 mag arcsec-2 for our “blue, diffuse” and “red, compact” classes respectively between redshift unity and the present day.

  10. Toward Spectroscopically Detecting the Global Latitudinal Temperature Variation on the Solar Surface

    NASA Astrophysics Data System (ADS)

    Takeda, Y.; UeNo, S.

    2017-09-01

    A very slight rotation-induced latitudinal temperature variation (presumably on the order of several kelvin) on the solar surface is theoretically expected. While recent high-precision solar brightness observations reported its detection, confirmation by an alternative approach using the strengths of spectral lines is desirable, for which reducing the noise due to random fluctuation caused by atmospheric inhomogeneity is critical. Toward this difficult task, we carried out a pilot study of spectroscopically investigating the relative variation of temperature (T) at a number of points in the solar circumference region near to the limb (where latitude dependence should be detectable, if any exists) based on the equivalent widths (W) of 28 selected lines in the 5367 - 5393 Å and 6075 - 6100 Å regions. We paid special attention to i) clarifying which types of lines should be employed and ii) how much precision is attainable in practice. We found that lines with strong T-sensitivity (|log W/log T|) should be used and that very weak lines should be avoided because they inevitably suffer strong relative fluctuations (Δ W/W). Our analysis revealed that a precision of Δ T/T ≈ 0.003 (corresponding to ≈ 15 K) can be achieved at best by a spectral line with comparatively large |log W/log T|, although this can possibly be further improved When a number of lines are used all together. Accordingly, if many such favorable lines could be measured with subpercent precision of Δ W/W and by averaging the resulting Δ T/T from each line, the random noise would eventually be reduced to ≲ 1 K and detection of a very subtle amount of global T-gradient might be possible.

  11. HST/COS detection of a Ne VIII absorber towards PG 1407+265: an unambiguous tracer of collisionally ionized hot gas?

    NASA Astrophysics Data System (ADS)

    Hussain, T.; Muzahid, S.; Narayanan, A.; Srianand, R.; Wakker, B. P.; Charlton, J. C.; Pathak, A.

    2015-01-01

    We report the detection of Ne VIII in a zabs = 0.599 61 absorber towards the QSO PG1407+265 (zem= 0.94). Besides Ne VIII, absorption from H I Lyman series lines (H I λ1025-λ915), several other low (C II, N II, O II and S II), intermediate (C III, N III, N IV, O III, S IV and S V) and high (S VI, O VI and Ne VIII) ionization metal lines are detected. Disparity in the absorption line kinematics between different ions implies that the absorbing gas comprises of multiple ionization phases. The low and the intermediate ions (except S V) trace a compact (˜410 pc), metal-rich (Z ˜ Z⊙) and overdense (log nH ˜ -2.6) photoionized region that sustained star formation for a prolonged period. The high ions, Ne VIII and O VI, can be explained as arising in a low density (-5.3 ≤ log nH ≤ -5.0), metal-rich (Z ≳ Z⊙) and diffuse (˜180 kpc) photoionized gas. The S V, S VI and C IV [detected in the Faint Object Spectrograph (FOS) spectrum] require an intermediate photoionization phase with -4.2 < log nH < -3.5. Alternatively, a pure collisional ionization model, as used to explain the previous known Ne VIII absorbers, with 5.65 < log T < 5.72, can reproduce the S VI, O VI and Ne VIII column densities simultaneously in a single phase. However, even such models require an intermediate phase to reproduce any observable S V and/or C IV. Therefore, we conclude that when multiple phases are present, the presence of Ne VIII is not necessarily an unambiguous indication of collisionally ionized hot gas.

  12. Cross-sectional survey of indicator and pathogenic bacteria on vegetables sold from Asian vendors at farmers' markets in northern California.

    PubMed

    Pan, Fengguang; Li, Xunde; Carabez, Jennifer; Ragosta, Guy; Fernandez, Kristine L; Wang, Elaine; Thiptara, Anyarat; Antaki, Elizabeth; Atwill, Edward R

    2015-03-01

    A cross-sectional survey was conducted during summer 2013 to determine the occurrence of Escherichia coli, fecal coliforms (FCs), E. coli O157:H7, and Salmonella on raw vegetable commodities common to Asian cuisine from 21 vendors or farmers at six farmers' markets in northern California. Based on 242 samples from six commodities (basil, yardlong beans, bitter squash, okra, squash stems and leaves, cilantro), 100% of samples had detectable FCs and 20% had detectable E. coli. The mean concentrations were 0.67 log CFU/g and 1.26 log CFU per bundle for E. coli and 4.00 log CFU/g and 6.26 log CFU per bundle for FCs. Vegetables irrigated with ground versus surface water contained lower concentrations of FCs, but this difference was not observed for E. coli. Yardlong beans, bitter squash, and okra had lower levels of FCs compared with basil, cilantro, and squash stems and leaves. Sixteen (6.6%) samples had detectable levels of Salmonella serovars (Newport, Enteritidis, Agona, and Worthington), with the majority of positives found in cilantro and squash stems and leaves. There was a twofold higher probability of Salmonella contamination in samples from growers or vendors who stated that they used organic farming practices compared with samples from those using conventional farming practices. Lastly, the concentrations of FC and E. coli bacteria were significantly associated with Salmonella contamination: for each additional 100 CFU/g or bundle, the probability of Salmonella contamination increased by ∼15 and ∼30%, respectively. None of the samples had detectable E. coli O157:H7.

  13. Combined Log Inventory and Process Simulation Models for the Planning and Control of Sawmill Operations

    Treesearch

    Guillermo A. Mendoza; Roger J. Meimban; Philip A. Araman; William G. Luppold

    1991-01-01

    A log inventory model and a real-time hardwood process simulation model were developed and combined into an integrated production planning and control system for hardwood sawmills. The log inventory model was designed to monitor and periodically update the status of the logs in the log yard. The process simulation model was designed to estimate various sawmill...

  14. Financial and Economic Analysis of Reduced Impact Logging

    Treesearch

    Tom Holmes

    2016-01-01

    Concern regarding extensive damage to tropical forests resulting from logging increased dramatically after World War II when mechanized logging systems developed in industrialized countries were deployed in the tropics. As a consequence, tropical foresters began developing logging procedures that were more environmentally benign, and by the 1990s, these practices began...

  15. Wane detection on rough lumber using surface approximation

    Treesearch

    Sang-Mook Lee; A. Lynn Abbott; Daniel L. Schmoldt

    2000-01-01

    The initial breakdown of hardwood logs into lumber produces boards with rough surfaces. These boards contain wane (missing wood due to the curved log exterior) that is removed by edge and trim cuts prior to sale. Because hardwood lumber value is determined using a combination of board size and quality, knowledge of wane position and defects is essential for selecting...

  16. Surface shape analysis of rough lumber for wane detection

    Treesearch

    Sang-Mook Lee; A. Lynn Abbott; Daniel L. Schmoldt

    2003-01-01

    The initial breakdown of hardwood logs into lumber produces boards with rough surfaces. These boards contain wane (missing wood that emanates from the log exterior, often containing residual bark) that is removed by edge and trim cuts prior to sale. Because hardwood lumber value is determined based on board size and quality, knowledge of wane position and defects is...

  17. Labeling Defects in CT Images of Hardwood Logs with Species-Dependent and Species-Independent Classifiers

    Treesearch

    Pei Li; Jing He; A. Lynn Abbott; Daniel L. Schmoldt

    1996-01-01

    This paper analyses computed tomography (CT) images of hardwood logs, with the goal of locating internal defects. The ability to detect and identify defects automatically is a critical component of efficiency improvements for future sawmills and veneer mills. This paper describes an approach in which 1) histogram equalization is used during preprocessing to normalize...

  18. How Intrusion Detection Can Improve Software Decoy Applications

    DTIC Science & Technology

    2003-03-01

    THIS PAGE INTENTIONALLY LEFT BLANK 41 V. DISCUSSION Military history suggests it is best to employ a layered, defense-in...database: alert, postgresql , user=snort dbname=snort # output database: log, unixodbc, user=snort dbname=snort # output database: log, mssql, dbname...Threat Monitoring and Surveillance, James P. Anderson Co., Fort Washington. PA, April 1980. URL http://csrc.nist.gov/publications/ history /ande80

  19. Portable acuity screening for any school: validation of patched HOTV with amblyopic patients and Bangerter normals.

    PubMed

    Tsao Wu, Maya; Armitage, M Diane; Trujillo, Claire; Trujillo, Anna; Arnold, Laura E; Tsao Wu, Lauren; Arnold, Robert W

    2017-12-04

    We needed to validate and calibrate our portable acuity screening tools so amblyopia could be detected quickly and effectively at school entry. Spiral-bound flip cards and download pdf surround HOTV acuity test box with critical lines were combined with a matching card. Amblyopic patients performed critical line, then threshold acuity which was then compared to patched E-ETDRS acuity. 5 normal subjects wore Bangerter foil goggles to simulate blur for comparative validation. The 31 treated amblyopic eyes showed: logMAR HOTV = 0.97(logMAR E-ETDRS)-0.04 r2 = 0.88. All but two (6%) fell less than 2 lines difference. The five showed logMAR HOTV = 1.09 ((logMAR E-ETDRS) + .15 r2 = 0.63. The critical-line, test box was 98% efficient at screening within one line of 20/40. These tools reliably detected acuity in treated amblyopic patients and Bangerter blurred normal subjects. These free and affordable tools provide sensitive screening for amblyopia in children from public, private and home schools. Changing "pass" criteria to 4 out of 5 would improve sensitivity with somewhat slower testing for all students.

  20. Microbiological Status and Food Safety Compliance of Commercial Basil Production Systems.

    PubMed

    de Bruin, Willeke; Otto, Denise; Korsten, Lise

    2016-01-01

    Basil has been implicated in a number of microbe-associated foodborne illnesses across the world, and the source of contamination has often been traced back to the production and/or processing stages of the supply chain. The aim of this study was to evaluate the microbiological quality of fresh basil from the point of production to the retail outlet in the Gauteng and Northwest Provinces of South Africa. A total of 463 samples were collected over a 3-month period from two large-scale commercial herb producing and processing companies and three retail outlets. The microbiological quality of the samples was assessed based on the presence or absence of Escherichia coli O157:H7 and Salmonella Typhimurium and the levels of the indicator bacteria E. coli and total coliforms. Salmonella Typhimurium was detected on four basil samples (0.9%) arriving at the processing facility and at dispatch, but no E. coli O157:H7 was detected throughout the study. Total coliform counts were 0.4 to 4.1 CFU/g for basil, 1.9 to 3.4 log CFU/ml for water, and 0.2 to 1.7 log CFU/cm(2) for contact surfaces, whereas E. coli was detected in the water samples and only once on basil. The Colilert-18 and membrane filter methods were used to analyze water samples, and a comparison of results revealed that the Colilert-18 method was more sensitive. Strong evidence suggests that high numbers of coliforms do not necessarily indicate the presence of Salmonella Typhimurium. The study results highlight the importance of effective implementation of food safety management systems in the fresh produce industry.

  1. Gulf of Mexico Gas Hydrate Joint Industry Project Leg II logging-while-drilling data acquisition and anaylsis

    USGS Publications Warehouse

    Collett, Timothy S.; Lee, Myung W.; Zyrianova, Margarita V.; Mrozewski, Stefan A.; Guerin, Gilles; Cook, Ann E.; Goldberg, Dave S.

    2012-01-01

    One of the objectives of the Gulf of MexicoGasHydrateJointIndustryProjectLegII (GOM JIP LegII) was the collection of a comprehensive suite of logging-while-drilling (LWD) data within gas-hydrate-bearing sand reservoirs in order to make accurate estimates of the concentration of gashydrates under various geologic conditions and to understand the geologic controls on the occurrence of gashydrate at each of the sites drilled during this expedition. The LWD sensors just above the drill bit provided important information on the nature of the sediments and the occurrence of gashydrate. There has been significant advancements in the use of downhole well-logging tools to acquire detailed information on the occurrence of gashydrate in nature: From using electrical resistivity and acoustic logs to identify gashydrate occurrences in wells to where wireline and advanced logging-while-drilling tools are routinely used to examine the petrophysical nature of gashydrate reservoirs and the distribution and concentration of gashydrates within various complex reservoir systems. Recent integrated sediment coring and well-log studies have confirmed that electrical resistivity and acoustic velocity data can yield accurate gashydrate saturations in sediment grain supported (isotropic) systems such as sand reservoirs, but more advanced log analysis models are required to characterize gashydrate in fractured (anisotropic) reservoir systems. In support of the GOM JIP LegII effort, well-log data montages have been compiled and presented in this report which includes downhole logs obtained from all seven wells drilled during this expedition with a focus on identifying and characterizing the potential gas-hydrate-bearing sedimentary section in each of the wells. Also presented and reviewed in this report are the gas-hydrate saturation and sediment porosity logs for each of the wells as calculated from available downhole well logs.

  2. The NetLogger Toolkit V2.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gunter, Dan; Lee, Jason; Stoufer, Martin

    2003-03-28

    The NetLogger Toolkit is designed to monitor, under actual operating conditions, the behavior of all the elements of the application-to-application communication path in order to determine exactly where time is spent within a complex system Using NetLogger, distnbuted application components are modified to produce timestamped logs of "interesting" events at all the critical points of the distributed system Events from each component are correlated, which allov^ one to characterize the performance of all aspects of the system and network in detail. The NetLogger Toolkit itself consists of four components an API and library of functions to simplify the generation ofmore » application-level event logs, a set of tools for collecting and sorting log files, an event archive system, and a tool for visualization and analysis of the log files In order to instrument an application to produce event logs, the application developer inserts calls to the NetLogger API at all the critical points in the code, then links the application with the NetLogger library All the tools in the NetLogger Toolkit share a common log format, and assume the existence of accurate and synchronized system clocks NetLogger messages can be logged using an easy-to-read text based format based on the lETF-proposed ULM format, or a binary format that can still be used through the same API but that is several times faster and smaller, with performance comparable or better than binary message formats such as MPI, XDR, SDDF-Binary, and PBIO. The NetLogger binary format is both highly efficient and self-describing, thus optimized for the dynamic message construction and parsing of application instrumentation. NetLogger includes an "activation" API that allows NetLogger logging to be turned on, off, or modified by changing an external file This IS useful for activating logging in daemons/services (e g GndFTP server). The NetLogger reliability API provides the ability to specify backup logging locations and penodically try to reconnect broken TCP pipe. A typical use for this is to store data on local disk while net is down. An event archiver can log one or more incoming NetLogger streams to a local disk file (netlogd) or to a mySQL database (netarchd). We have found exploratory, visual analysis of the log event data to be the most useful means of determining the causes of performance anomalies The NetLogger Visualization tool, niv, has been developed to provide a flexible and interactive graphical representation of system-level and application-level events.« less

  3. Rapid Detection of Escherichia coli O157:H7 in Fresh Lettuce Based on Localized Surface Plasmon Resonance Combined with Immunomagnetic Separation.

    PubMed

    Lee, Nari; Choi, Sung-Wook; Chang, Hyun-Joo; Chun, Hyang Sook

    2018-05-01

    This study presents a method for rapid detection of Escherichia coli O157:H7 in fresh lettuce based on the properties of target separation and localized surface plasmon resonance of immunomagnetic nanoparticles. The multifunctional immunomagnetic nanoparticles enabling simultaneous separation and detection were prepared by synthesizing magnetic nanoparticles (ca. 10 nm in diameter) composed of an iron oxide (Fe 3 O 4 ) core and gold shell and then conjugating these nanoparticles with the anti- E. coli O157:H7 antibodies. The application of multifunctional immunomagnetic nanoparticles for detecting E. coli O157:H7 in a lettuce matrix allowed detection of the presence of <1 log CFU mL -1 without prior enrichment. In contrast, the detection limit of the conventional plating method was 2.74 log CFU mL -1 . The method, which requires no preenrichment, provides an alternative to conventional microbiological detection methods and can be used as a rapid screening tool for a large number of food samples.

  4. Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA.

    PubMed

    Majid, Farjana; Jahan, Munira; Lutful Moben, Ahmed; Tabassum, Shahina

    2014-01-01

    Both real-time-polymerase chain reaction (PCR) and hybrid capture 2 (HC2) assay can detect and quantify hepatitis B virus (HBV) DNA. However, real-time-PCR can detect a wide range of HBV DNA, while HC2 assay could not detect lower levels of viremia. The present study was designed to detect and quantify HBV DNA by real-time-PCR and HC2 assay and compare the quantitative data of these two assays. A cross-sectional study was conducted in between July 2010 and June 2011. A total of 66 serologically diagnosed chronic hepatitis B (CHB) patients were selected for the study. Real-time-PCR and HC2 assay was done to detect HBV DNA. Data were analyzed by statistical Package for the social sciences (SPSS). Among 66 serologically diagnosed chronic hepatitis B patients 40 (60.61%) patients had detectable and 26 (39.39%) had undetectable HBV DNA by HC2 assay. Concordant results were obtained for 40 (60.61%) out of these 66 patients by real-time-PCR and HC2 assay with mean viral load of 7.06 ± 1.13 log 10 copies/ml and 6.95 ± 1.08 log 10 copies/ml, respectively. In the remaining 26 patients, HBV DNA was detectable by real-time-PCR in 20 patients (mean HBV DNA level was 3.67 ± 0.72 log 10 copies/ml. However, HBV DNA could not be detectable in six cases by the both assays. The study showed strong correlation (r = 0.915) between real-time-PCR and HC2 assay for the detection and quantification of HBV DNA. HC2 assay may be used as an alternative to real-time-PCR for CHB patients. How to cite this article: Majid F, Jahan M, Moben AL, Tabassum S. Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA. Euroasian J Hepato-Gastroenterol 2014;4(1):31-35.

  5. The relationship between land management, fecal indicator bacteria, and the occurrence of Campylobacter and Listeria spp. in water and sediments during synoptic sampling in the S. Fork Broad River Watershed, N.E. Georgia, U.S.A

    NASA Astrophysics Data System (ADS)

    Bradshaw, J. K.; Molina, M.; Sidle, R. C.; Sullivan, K.; Oakley, B.; Berrang, M.; Meinersmann, R.

    2013-12-01

    Fecal indicator bacteria (FIB) and pathogens stored in the bed sediments of streams and rivers may be mobilized into the water column affecting overall water quality. Furthermore, land management may play an important role in the concentrations of FIB and the occurrence of pathogens in stream water and sediments. The purpose of this study was to determine the relationship between FIB and pathogens in stream water and sediment based on three land management-affected categories: agricultural, forest, and waters receiving treated municipal wastewater. Two synoptic sampling events were conducted under baseflow conditions (<0.64 cm of rain within 24h) between October-November, 2012 and May-June, 2013. Counts of the E. coli and E. faecalis and occurrences of the enteric pathogens Campylobacter and Listeria spp. were measured in stream water and sediment samples collected at 15 locations (six agricultural (AG); six forested (FORS); and three receiving discharge from water pollution control plants (WPCP)) in the S. Fork Broad River watershed located in northeast Georgia, USA. Mean E. coli and E. faecalis concentrations were highest in the AG stream water samples (3.08 log MPN 100 mL -1 for E. coli and 3.07 log CFU 100 mL -1 for E. faecalis ) and lowest in the FORS water samples for E. coli (2.37 log MPN 100 mL -1 ) and WPCP water samples for E. faecalis (2.53 log CFU 100 mL -1 ). E. coli concentrations (2.74 log MPN 100 mL -1 ) in the WPCP streams were intermediate. Similar to water samples, E. coli concentrations were highest in the AG sediments (4.31 log MPN g -1 ), intermediate in the WPCP sediments (4.06 log MPN g -1 ), and lowest in the FORS sediments (3.46 log MPN g -1 ). In contrast to E. coli, E. faecalis concentrations were lower (1.10 to 1.31 log CFU g -1 ) and relatively more constant than E. coli in sediments over the three land management categories. Campylobacter was detected in 27% of the water samples and 8% of the sediment samples. The highest occurrence of Campylobacter detection was in the AG streams (15% of the water samples; 5% of the sediment samples). Listeria was detected in 76% of the water samples and 65% of the sediment samples. The FORS and AG streams had the highest occurrence of Listeria in water and sediment (32% and 29% of the water samples, respectively; 24% and 29% of sediment samples, respectively) suggesting Listeria is fairly ubiquitous in these streams. Based on the high concentrations of E. faecalis in water and E. coli in water and sediment, and higher frequency of Campylobacter detection in the AG streams, this study indicates that E. coli and Campylobacter may occur in high concentrations in stream sediments in land management areas where fecal material is deposited directly by livestock into the stream or adjacent land in large doses.

  6. Microfluidic biosensing systems. Part I. Development and optimisation of enzymatic chemiluminescent micro-biosensors based on silicon microchips.

    PubMed

    Davidsson, Richard; Genin, Frédéric; Bengtsson, Martin; Laurell, Thomas; Emnéus, Jenny

    2004-10-01

    Chemiluminescent (CL) enzyme-based flow-through microchip biosensors (micro-biosensors) for detection of glucose and ethanol were developed for the purpose of monitoring real-time production and release of glucose and ethanol from microchip immobilised yeast cells. Part I of this study focuses on the development and optimisation of the micro-biosensors in a microfluidic sequential injection analysis (microSIA) system. Glucose oxidase (GOX) or alcohol oxidase (AOX) was co-immobilised with horseradish peroxidase (HRP) on porous silicon flow through microchips. The hydrogen peroxide produced from oxidation of the corresponding analyte (glucose or ethanol) took part in the chemiluminescent (CL) oxidation of luminol catalysed by HRP enhanced by addition of p-iodophenol (PIP). All steps in the microSIA system, including control of syringe pump, multiposition valve (MPV) and data readout, were computer controlled. The influence of flow rate and luminol- and PIP concentration were investigated using a 2(3)-factor experiment using the GOX-HRP sensor. It was found that all estimated single factors and the highest order of interaction were significant. The optimum was found at 250 microM luminol and 150 microM PIP at a flow rate of 18 microl min(-1), the latter as a compromise between signal intensity and analysis time. Using the optimised system settings one sample was processed within 5 min. Two different immobilisation chemistries were investigated for both micro-biosensors based on 3-aminopropyltriethoxsilane (APTS)- or polyethylenimine (PEI) functionalisation followed by glutaraldehyde (GA) activation. GOX-HRP micro-biosensors responded linear in a log-log format within the range 10-1000 microM glucose. Both had an operational stability of at least 8 days, but the PEI-GOX-HRP sensor was more sensitive. The AOX-HRP micro-biosensors responded linear (log-log) in the range between 1 and 10 mM ethanol, but the PEI-AOX-HRP sensor was in general more sensitive. Both sensors had an operational stability of at least 8 h, but with a half-life of 2-3 days.

  7. Comparative evaluation of new TaqMan real-time assays for the detection of hepatitis A virus.

    PubMed

    Houde, Alain; Guévremont, Evelyne; Poitras, Elyse; Leblanc, Danielle; Ward, Pierre; Simard, Carole; Trottier, Yvon-Louis

    2007-03-01

    Three novel real-time TaqMan RT-PCR assays targeting the 5'-UTR, the viral protease and the viral polymerase regions of the hepatitis A virus (HAV) were developed, evaluated and compared against a new published 5'-UTR TaqMan assay (JN) and a widely used conventional RT-PCR assay (HAVc). All conventional RT-PCR (HAV, SH-Prot and SH-Poly systems) and TaqMan (SH-Prot, SH-Poly, JN and SH-5U systems) assays evaluated were consistent for the detection of the three different HAV strains (HM-175, HAS-15 and LSH/S) used and reproducible for both RNA duplicates with the exception of two reproducibility discrepancies observed with both 5'-UTR real-time systems (JN and SH-5U). Limits of detection for conventional HAV, SH-Prot and SH-Poly RT-PCR systems were found to be equivalent when tested with serially diluted suspensions of the HM-175 strain. Although the four real-time RT-PCR TaqMan assays evaluated herein produced similar and consistent quantification data down to the level of one genomic equivalent copy with their respectively cloned amplicons, significant and important differences were observed for the detection of HAV genomic RNA. Results showed that the new real-time TaqMan SH-Poly and SH-Prot primer and probe systems were more consistent and sensitive by 5 logs as compared to both 5'-UTR designs (JN and SH-5U) used for the detection of HAV genomic RNA as well as for the detection in cell culture by cytopathic effect. Considering their higher analytical sensitivity, the proposed SH-Poly and SH-Prot amplification systems could therefore represent valuable tools for the detection of HAV in clinical, environmental and food samples.

  8. A Field Study of NMR Logging to Quantify Petroleum Contamination in Subsurface Sediments

    NASA Astrophysics Data System (ADS)

    Fay, E. L.; Knight, R. J.; Grunewald, E. D.

    2016-12-01

    Nuclear magnetic resonance (NMR) measurements are directly sensitive to hydrogen-bearing fluids including water and petroleum products. NMR logging tools can be used to detect and quantify petroleum hydrocarbon contamination in the sediments surrounding a well or borehole. An advantage of the NMR method is that data can be collected in both cased and uncased holes. In order to estimate the volume of in-situ hydrocarbon, there must be sufficient contrast between either the relaxation times (T2) or the diffusion coefficients (D) of water and the contaminant. In a field study conducted in Pine Ridge, South Dakota, NMR logging measurements were used to investigate an area of hydrocarbon contamination from leaking underground storage tanks. A contaminant sample recovered from a monitoring well at the site was found to be consistent with a mixture of gasoline and diesel fuel. NMR measurements were collected in two PVC-cased monitoring wells; D and T2 measurements were used together to detect and quantify contaminant in the sediments above and below the water table at both of the wells. While the contrast in D between the fluids was found to be inadequate for fluid typing, the T2 contrast between the contaminant and water in silt enabled the estimation of the water and contaminant volumes. This study shows that NMR logging can be used to detect and quantify in-situ contamination, but also highlights the importance of sediment and contaminant properties that lead to a sufficiently large contrast in T2 or D.

  9. Comparison between moving and stationary transmitter systems in induction logging

    NASA Astrophysics Data System (ADS)

    Poddar, M.; Caleb Dhanasekaran, P.; Prabhakar Rao, K.

    1985-09-01

    In a general treatment of the theory of induction logging, an exact integral representation has been obtained for the mutual impedance between a vertical dipole transmitter and a coaxial dipole receiver in a three layered earth. Based on this representation, a computer model has been devised using the traditional Slingram system of induction logging and the comparatively new Turam system, ignoring borehole effects. The model results indicate that due to its much larger response, the Turam system is in general preferable to the Slingram in mineral and groundwater investigations where formation conductivity much less than 1 S/m is generally encountered. However, if the surrounding media are conductive (more than 0.1 S/m), the Turam system suffers from large amplitude attenuation and phase rotation of the primary field caused by the conductive surrounding, and is less useful than the Slingram system which does not so suffer, unless the target bed is shallow. Because it is a more complex function of system parameters than the corresponding Slingram log, a Turam log can be conveniently interpreted only by the modern inverse method using a fast algorithm for the forward solution and a high speed digital computer.

  10. Orthos, an alarm system for the ALICE DAQ operations

    NASA Astrophysics Data System (ADS)

    Chapeland, Sylvain; Carena, Franco; Carena, Wisla; Chibante Barroso, Vasco; Costa, Filippo; Denes, Ervin; Divia, Roberto; Fuchs, Ulrich; Grigore, Alexandru; Simonetti, Giuseppe; Soos, Csaba; Telesca, Adriana; Vande Vyvre, Pierre; von Haller, Barthelemy

    2012-12-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector studying the physics of strongly interacting matter and the quark-gluon plasma at the CERN LHC (Large Hadron Collider). The DAQ (Data Acquisition System) facilities handle the data flow from the detectors electronics up to the mass storage. The DAQ system is based on a large farm of commodity hardware consisting of more than 600 devices (Linux PCs, storage, network switches), and controls hundreds of distributed hardware and software components interacting together. This paper presents Orthos, the alarm system used to detect, log, report, and follow-up abnormal situations on the DAQ machines at the experimental area. The main objective of this package is to integrate alarm detection and notification mechanisms with a full-featured issues tracker, in order to prioritize, assign, and fix system failures optimally. This tool relies on a database repository with a logic engine, SQL interfaces to inject or query metrics, and dynamic web pages for user interaction. We describe the system architecture, the technologies used for the implementation, and the integration with existing monitoring tools.

  11. Instrument response measurements of ion mobility spectrometers in situ: maintaining optimal system performance of fielded systems

    NASA Astrophysics Data System (ADS)

    Wallis, Eric; Griffin, Todd M.; Popkie, Norm, Jr.; Eagan, Michael A.; McAtee, Robert F.; Vrazel, Danet; McKinly, Jim

    2005-05-01

    Ion Mobility Spectroscopy (IMS) is the most widespread detection technique in use by the military for the detection of chemical warfare agents, explosives, and other threat agents. Moreover, its role in homeland security and force protection has expanded due, in part, to its good sensitivity, low power, lightweight, and reasonable cost. With the increased use of IMS systems as continuous monitors, it becomes necessary to develop tools and methodologies to ensure optimal performance over a wide range of conditions and extended periods of time. Namely, instrument calibration is needed to ensure proper sensitivity and to correct for matrix or environmental effects. We have developed methodologies to deal with the semi-quantitative nature of IMS and allow us to generate response curves that allow a gauge of instrument performance and maintenance requirements. This instrumentation communicates to the IMS systems via a software interface that was developed in-house. The software measures system response, logs information to a database, and generates the response curves. This paper will discuss the instrumentation, software, data collected, and initial results from fielded systems.

  12. A Security Monitoring Framework For Virtualization Based HEP Infrastructures

    NASA Astrophysics Data System (ADS)

    Gomez Ramirez, A.; Martinez Pedreira, M.; Grigoras, C.; Betev, L.; Lara, C.; Kebschull, U.; ALICE Collaboration

    2017-10-01

    High Energy Physics (HEP) distributed computing infrastructures require automatic tools to monitor, analyze and react to potential security incidents. These tools should collect and inspect data such as resource consumption, logs and sequence of system calls for detecting anomalies that indicate the presence of a malicious agent. They should also be able to perform automated reactions to attacks without administrator intervention. We describe a novel framework that accomplishes these requirements, with a proof of concept implementation for the ALICE experiment at CERN. We show how we achieve a fully virtualized environment that improves the security by isolating services and Jobs without a significant performance impact. We also describe a collected dataset for Machine Learning based Intrusion Prevention and Detection Systems on Grid computing. This dataset is composed of resource consumption measurements (such as CPU, RAM and network traffic), logfiles from operating system services, and system call data collected from production Jobs running in an ALICE Grid test site and a big set of malware samples. This malware set was collected from security research sites. Based on this dataset, we will proceed to develop Machine Learning algorithms able to detect malicious Jobs.

  13. Survival and detection of Bacillus cereus in the presence of Escherichia coli, Salmonella enteritidis, Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans after rechallenge in make-up removers.

    PubMed

    Yossa, N; Arce, G; Smiley, J; Jo Huang, M-C; Yin, L; Bell, R; Tallent, S; Brown, E; Hammack, T

    2018-02-01

    Pathogenic contamination of cosmetics intended to be applied on or around the eye area, including make-up removers, may lead to severe eye infections. To assess the efficacy of antimicrobial preservatives in these products, we investigated the survival and detection of Bacillus cereus F 4227A spiked into make-up removers, alone and in the presence of other relevant micro-organisms. Four brands of make-up removers, A, B, C and D, were challenged three times (day 0, day 7 and day 14) using B. cereus, in pure and mixed cultures, at a final concentration of 5 log CFU per mL of Bacillus cereus or 6 log CFU per mL for other micro-organisms. Inoculated samples were diluted and spiral-plated after 30 min and 24 h of each challenge onto selective media for recovery of surviving micro-organisms: BACARA (B. cereus), MacConkey (E. coli), ChromID (P. aeruginosa), XLT4 (S. enteritidis), Baird Parker agar (Staph. aureus) and PDA+chlortetracycline HCL (C. albicans). The population of B. cereus spiked as a pure culture increased significantly from the first to the third challenge after 30-min exposure time, going from 0.73 to 2.59 in A, from 0.80 to 2.69 in B and from 0.80 to 1.67 log CFU per mL in C (P < 0.05). Likewise, the B. cereus population from the mixed cultures had a significantly higher survival count at the third challenge: from 0.12 log MPN per mL to 2.16 log CFU per mL in A, 0.57 to 2.27 log CFU per mL in B and from undetected (LOD = 0.48 log MPN) to 0.98 log CFU per mL in C, respectively. After challenges, Staph. aureus, C. albicans and P. aeruginosa increased in B; Staph. aureus and C. albicans in C; and E. coli and Staph. aureus in D. The growth of other bacteria types was unaffected by the number of challenges, but B. cereus population was detected with the third challenge. It is appropriate to assess the antimicrobial efficacy of preservatives using at least three challenges, especially for cosmetics that are subjected to repetitive contamination by users. © 2017 U.S. Food and Drug Administration. International Journal of Cosmetic Science published by John Wiley & Sons Ltd on behalf of Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  14. The association of serum β-hydroxybutyrate concentration with fetal number and health indicators in late-gestation ewes in commercial meat flocks in Prince Edward Island.

    PubMed

    Ratanapob, Niorn; VanLeeuwen, John; McKenna, Shawn; Wichtel, Maureen; Rodriguez-Lecompte, Juan C; Menzies, Paula; Wichtel, Jeffrey

    2018-06-01

    Late-gestation ewes are susceptible to ketonemia resulting from high energy requirement for fetal growth during the last few weeks of pregnancy. High lamb mortality is a possible consequence of effects of ketonemia on both ewes and lambs. Determining risk factors to ketonemia is a fundamental step to identify ewes at risk, in order to avoid losses caused by ketonemia. Serum β-hydroxybutyrate (BHBA) concentrations of 384 late-gestation ewe samples were determined. Physical examinations, including body condition, FAMACHA © and hygiene scoring, were performed. Udders and teeth were also examined. Fecal floatation was performed to detect gastrointestinal helminth eggs of the ewe fecal samples. General feeding management practices and season at sampling were recorded. Litter sizes were retrieved from lambing records. Factors associated with log serum BHBA concentration were determined using a linear mixed model, with flock and lambing groups as random effects. The mean serum BHBA concentration was 545.8 (±453.3) μmol/l. Ewes with a body condition score (BCS) of 2.5-3.5 had significantly lower log BHBA concentrations than ewes with a BCS of ≤2.0, by 19.7% (p = 0.035). Ewes with a BCS of >3.5 had a trend toward higher log BHBA concentrations compared to ewes with a BCS of 2.5-3.5. Ewes with a FAMACHA © score of 3 had significantly higher log BHBA concentrations than ewes with a FAMACHA © score of 1 or 2, by 12.1% (p = 0.049). Ewes in which gastrointestinal helminth eggs were detected had significantly higher log BHBA concentrations than ewes in which helminth eggs were not detected, by 12.3% (p = 0.040). An increased litter size was associated with higher log BHBA concentration (p ≤ 0.003), with the log BHBA concentrations of ewes having twins, triplets, and quadruplets or quintuplets were higher than those of ewes having singleton by 19.2%, 30.4%, and 85.2%, respectively. Season at sampling confounded the association between log BHBA concentration and FAMACHA © score, and therefore was retained in the final model even though it was not statistically significant. Intra-class correlation coefficients at the flock and lambing group levels were 0.14 and 0.32, respectively. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  15. Microbial Removals by a Novel Biofilter Water Treatment System

    PubMed Central

    Wendt, Christopher; Ives, Rebecca; Hoyt, Anne L.; Conrad, Ken E.; Longstaff, Stephanie; Kuennen, Roy W.; Rose, Joan B.

    2015-01-01

    Two point-of-use drinking water treatment systems designed using a carbon filter and foam material as a possible alternative to traditional biosand systems were evaluated for removal of bacteria, protozoa, and viruses. Two configurations were tested: the foam material was positioned vertically around the carbon filter in the sleeve unit or horizontally in the disk unit. The filtration systems were challenged with Cryptosporidium parvum, Raoultella terrigena, and bacteriophages P22 and MS2 before and after biofilm development to determine average log reduction (ALR) for each organism and the role of the biofilm. There was no significant difference in performance between the two designs, and both designs showed significant levels of removal (at least 4 log10 reduction in viruses, 6 log10 for protozoa, and 8 log10 for bacteria). Removal levels meet or exceeded Environmental Protection Agency (EPA) standards for microbial purifiers. Exploratory test results suggested that mature biofilm formation contributed 1–2 log10 reductions. Future work is recommended to determine field viability. PMID:25758649

  16. Acoustic detection of Oryctes rhinoceros (Coleoptera: Scarabaeidae: Dynastinae) and Nasutitermes luzonicus (Isoptera: Termitidae) in palm trees in urban Guam.

    PubMed

    Mankin, R W; Moore, A

    2010-08-01

    Adult and larval Oryctes rhinoceros (L.) (Coleoptera: Scarabaeidae: Dynastinae) were acoustically detected in live and dead palm trees and logs in recently invaded areas of Guam, along with Nasutitermes luzonicus Oshima (Isoptera: Termitidae), and other small, sound-producing invertebrates and invertebrates. The low-frequency, long-duration sound-impulse trains produced by large, active O. rhinoceros and the higher frequency, shorter impulse trains produced by feeding N. luzonicus had distinctive spectral and temporal patterns that facilitated their identification and discrimination from background noise, as well as from roaches, earwigs, and other small sound-producing organisms present in the trees and logs. The distinctiveness of the O. rhinoceros sounds enables current usage of acoustic detection as a tactic in Guam's ongoing O. rhinoceros eradication program.

  17. Radio core dominance of Fermi blazars

    NASA Astrophysics Data System (ADS)

    Pei, Zhi-Yuan; Fan, Jun-Hui; Liu, Yi; Yuan, Yi-Hai; Cai, Wei; Xiao, Hu-Bing; Lin, Chao; Yang, Jiang-He

    2016-07-01

    During the first 4 years of mission, Fermi/LAT detected 1444 blazars (3FGL) (Ackermann et al. in Astrophys. J. 810:14, 2015). Fermi/LAT observations of blazars indicate that Fermi blazars are luminous and strongly variable with variability time scales, for some cases, as short as hours. Those observations suggest a strong beaming effect in Fermi/LAT blazars. In the present work, we will investigate the beaming effect in Fermi/LAT blazars using a core-dominance parameter, R = S_{core}/ S_{ext.}, where S_{core} is the core emission, while S_{ext.} is the extended emission. We compiled 1335 blazars with available core-dominance parameter, out of which 169 blazars have γ-ray emission (from 3FGL). We compared the core-dominance parameters, log R, between the 169 Fermi-detected blazars (FDBs) and the rest non-Fermi-detected blazars (non-FDBs), and we found that the averaged values are < log Rrangle = 0.99±0.87 for FDBs and < log Rrangle = -0.62±1.15 for the non-FDBs. A K-S test shows that the probability for the two distributions of FDBs and non-FDBs to come from the same parent distribution is near zero (P =9.12×10^{-52}). Secondly, we also investigated the variability index (V.I.) in the γ-ray band for FDBs, and we found V.I.=(0.12 ±0.07) log R+(2.25±0.10), suggesting that a source with larger log R has larger V.I. value. Thirdly, we compared the mean values of radio spectral index for FDBs and non-FDBs, and we obtained < α_{radio}rangle =0.06±0.35 for FDBs and < α_{radio}rangle =0.57±0.46 for non-FDBs. If γ-rays are composed of two components like radio emission (core and extended components), then we can expect a correlation between log R and the γ-ray spectral index. When we used the radio core-dominance parameter, log R, to investigate the relationship, we found that the spectral index for the core component is α_{γ}|_{core} = 1.11 (a photon spectral index of α_{γ}^{ph}|_{core} = 2.11) and that for the extended component is α_{γ}|_{ext.} = 0.70 (a photon spectral index of α_{γ}^{ph}|_{ext.} = 1.70). Some discussions are also presented.

  18. Antiretroviral-treated HIV-1 patients can harbour resistant viruses in CSF despite an undetectable viral load in plasma.

    PubMed

    Soulie, Cathia; Grudé, Maxime; Descamps, Diane; Amiel, Corinne; Morand-Joubert, Laurence; Raymond, Stéphanie; Pallier, Coralie; Bellecave, Pantxika; Reigadas, Sandrine; Trabaud, Mary-Anne; Delaugerre, Constance; Montes, Brigitte; Barin, Francis; Ferré, Virginie; Jeulin, Hélène; Alloui, Chakib; Yerly, Sabine; Signori-Schmuck, Anne; Guigon, Aurélie; Fafi-Kremer, Samira; Haïm-Boukobza, Stéphanie; Mirand, Audrey; Maillard, Anne; Vallet, Sophie; Roussel, Catherine; Assoumou, Lambert; Calvez, Vincent; Flandre, Philippe; Marcelin, Anne-Geneviève

    2017-08-01

    HIV therapy reduces the CSF HIV RNA viral load (VL) and prevents disorders related to HIV encephalitis. However, these brain disorders may persist in some cases. A large population of antiretroviral-treated patients who had a VL > 1.7 log 10 copies/mL in CSF with detectable or undetectable VL in plasma associated with cognitive impairment was studied, in order to characterize discriminatory factors of these two patient populations. Blood and CSF samples were collected at the time of neurological disorders for 227 patients in 22 centres in France and 1 centre in Switzerland. Genotypic HIV resistance tests were performed on CSF. The genotypic susceptibility score was calculated according to the last Agence Nationale de Recherche sur le Sida et les hépatites virales Action Coordonnée 11 (ANRS AC11) genotype interpretation algorithm. Among the 227 studied patients with VL > 1.7 log 10 copies/mL in CSF, 195 had VL detectable in plasma [median (IQR) HIV RNA was 3.7 (2.7-4.7) log 10 copies/mL] and 32 had discordant VL in plasma (VL < 1.7 log 10 copies/mL). The CSF VL was lower (median 2.8 versus 4.0 log 10 copies/mL; P  <   0.001) and the CD4 cell count was higher (median 476 versus 214 cells/mm 3 ; P  <   0.001) in the group of patients with VL < 1.7 log 10 copies/mL in plasma compared with patients with plasma VL > 1.7 log 10 copies/mL. Resistance to antiretrovirals was observed in CSF for the two groups of patients. Fourteen percent of this population of patients with cognitive impairment and detectable VL in CSF had well controlled VL in plasma. Thus, it is important to explore CSF HIV (VL and genotype) even if the HIV VL is controlled in plasma because HIV resistance may be observed. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. The conservation value of South East Asia's highly degraded forests: evidence from leaf-litter ants

    PubMed Central

    Woodcock, Paul; Edwards, David P.; Fayle, Tom M.; Newton, Rob J.; Khen, Chey Vun; Bottrell, Simon H.; Hamer, Keith C.

    2011-01-01

    South East Asia is widely regarded as a centre of threatened biodiversity owing to extensive logging and forest conversion to agriculture. In particular, forests degraded by repeated rounds of intensive logging are viewed as having little conservation value and are afforded meagre protection from conversion to oil palm. Here, we determine the biological value of such heavily degraded forests by comparing leaf-litter ant communities in unlogged (natural) and twice-logged forests in Sabah, Borneo. We accounted for impacts of logging on habitat heterogeneity by comparing species richness and composition at four nested spatial scales, and examining how species richness was partitioned across the landscape in each habitat. We found that twice-logged forest had fewer species occurrences, lower species richness at small spatial scales and altered species composition compared with natural forests. However, over 80 per cent of species found in unlogged forest were detected within twice-logged forest. Moreover, greater species turnover among sites in twice-logged forest resulted in identical species richness between habitats at the largest spatial scale. While two intensive logging cycles have negative impacts on ant communities, these degraded forests clearly provide important habitat for numerous species and preventing their conversion to oil palm and other crops should be a conservation priority. PMID:22006966

  20. Biotransformation in Double-Phase Systems: Physiological Responses of Pseudomonas putida DOT-T1E to a Double Phase Made of Aliphatic Alcohols and Biosynthesis of Substituted Catechols

    PubMed Central

    Rojas, Antonia; Duque, Estrella; Schmid, Andreas; Hurtado, Ana; Ramos, Juan-Luis; Segura, Ana

    2004-01-01

    Pseudomonas putida strain DOT-T1E is highly tolerant to organic solvents, with a logPow (the logarithm of the partition coefficient of a solvent in a two-phase water-octanol system of ≥2.5. Solvent tolerant microorganisms can be exploited to develop double-phase (organic solvent and water) biotransformation systems in which toxic substrates or products are kept in the organic phase. We tested P. putida DOT-T1E tolerance to different aliphatic alcohols with a logPow value between 2 and 4, such as decanol, nonanol, and octanol, which are potentially useful in biotransformations in double-phase systems in which compounds with a logPow around 1.5 are produced. P. putida DOT-T1E responds to aliphatic alcohols as the second phase through cis-to-trans isomerization of unsaturated cis fatty acids and through efflux of these aliphatic alcohols via a series of pumps that also extrude aromatic hydrocarbons. These defense mechanisms allow P. putida DOT-T1E to survive well in the presence of high concentrations of the aliphatic alcohols, and growth with nonanol or decanol occurred at a high rate, whereas in the presence of an octanol double-phase growth was compromised. Our results support that the logPow of aliphatic alcohols correlates with their toxic effects, as octanol (logPow = 2.9) has more negative effects in P. putida cells than 1-nonanol (logPow = 3.4) or 1-decanol (logPow = 4). A P. putida DOT-T1E derivative bearing plasmid pWW0-xylE::Km transforms m-xylene (logPow = 3.2) into 3-methylcatechol (logPow = 1.8). The amount of 3-methylcatechol produced in an aliphatic alcohol/water bioreactor was 10- to 20-fold higher than in an aqueous medium, demonstrating the usefulness of double-phase systems for this particular biotransformation. PMID:15184168

  1. Automated method for measuring the extent of selective logging damage with airborne LiDAR data

    NASA Astrophysics Data System (ADS)

    Melendy, L.; Hagen, S. C.; Sullivan, F. B.; Pearson, T. R. H.; Walker, S. M.; Ellis, P.; Kustiyo; Sambodo, Ari Katmoko; Roswintiarti, O.; Hanson, M. A.; Klassen, A. W.; Palace, M. W.; Braswell, B. H.; Delgado, G. M.

    2018-05-01

    Selective logging has an impact on the global carbon cycle, as well as on the forest micro-climate, and longer-term changes in erosion, soil and nutrient cycling, and fire susceptibility. Our ability to quantify these impacts is dependent on methods and tools that accurately identify the extent and features of logging activity. LiDAR-based measurements of these features offers significant promise. Here, we present a set of algorithms for automated detection and mapping of critical features associated with logging - roads/decks, skid trails, and gaps - using commercial airborne LiDAR data as input. The automated algorithm was applied to commercial LiDAR data collected over two logging concessions in Kalimantan, Indonesia in 2014. The algorithm results were compared to measurements of the logging features collected in the field soon after logging was complete. The automated algorithm-mapped road/deck and skid trail features match closely with features measured in the field, with agreement levels ranging from 69% to 99% when adjusting for GPS location error. The algorithm performed most poorly with gaps, which, by their nature, are variable due to the unpredictable impact of tree fall versus the linear and regular features directly created by mechanical means. Overall, the automated algorithm performs well and offers significant promise as a generalizable tool useful to efficiently and accurately capture the effects of selective logging, including the potential to distinguish reduced impact logging from conventional logging.

  2. Compositional and physicochemical factors governing the viability of Lactobacillus rhamnosus GG embedded in starch-protein based edible films

    PubMed Central

    Soukoulis, Christos; Singh, Poonam; Macnaughtan, William; Parmenter, Christopher; Fisk, Ian D.

    2016-01-01

    Probiotic incorporation in edible films and coatings has been shown recently to be an efficient strategy for the delivery of probiotics in foods. In the present work, the impact of the compositional, physicochemical and structural properties of binary starch-protein edible films on Lactobacillus rhamnosus GG viability and stability was evaluated. Native rice and corn starch, as well as bovine skin gelatine, sodium caseinate and soy protein concentrate were used for the fabrication of the probiotic edible films. Starch and protein type both impacted the structural, mechanical, optical and thermal properties of the films, and the process loss of L. rhamnosus GG during evaporation-dehydration was significantly lower in the presence of proteins (0.91–1.07 log CFU/g) compared to solely starch based systems (1.71 log CFU/g). A synergistic action between rice starch and proteins was detected when monitoring the viability of L. rhamnosus GG over four weeks at fridge and room temperature conditions. In particular, a 3- to 7-fold increase in the viability of L. rhamnosus GG was observed in the presence of proteins, with sodium caseinate – rice starch based films offering the most enhanced stability. The film's shelf-life (as calculated using the FAO/WHO (2011) basis of 6 log viable CFU/g) ranged between 27-96 and 15–24 days for systems stored at fridge or room temperature conditions respectively. PMID:26726280

  3. Blazar Duty-Cycle at Gamma-Ray Frequecies: Constraints From Extragalactic Background Radiation And Prospects for AGILE And GLAST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pittori, Carlotta; Cavazzuti, Elisabetta; Colafrancesco, Sergio

    2011-11-29

    We take into account the constraints from the observed extragalactic {gamma}-ray background to estimate the maximum duty cycle allowed for a selected sample of WMAP Blazars, in order to be detectable by AGILE and GLAST {gamma}-ray experiments. For the nominal sensitivity values of both instruments, we identify a subset of sources which can in principle be detectable also in a steady state without over-predicting the extragalactic background. This work is based on the results of a recently derived Blazar radio LogN-LogS obtained by combining several multi-frequency surveys.

  4. Native Fluorescence Detection Methods, Devices, and Systems for Organic Compounds

    NASA Technical Reports Server (NTRS)

    Hug, William F. (Inventor); Bhartia, Rohit (Inventor); Lane, Arthur L. (Inventor); Reid, Ray D. (Inventor)

    2018-01-01

    Naphthalene, benzene, toluene, xylene, and other volatile organic compounds VOCs have been identified as serious health hazards. Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined.

  5. Native Fluorescence Detection Methods, Devices, and Systems for Organic Compounds

    NASA Technical Reports Server (NTRS)

    Hug, William F. (Inventor); Reid, Ray D. (Inventor); Lane, Arthur L. (Inventor); Bhartia, Rohit (Inventor)

    2016-01-01

    Naphthalene, benzene, toluene, xylene, and other volatile organic compounds VOCs have been identified as serious health hazards. Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined.

  6. Mechanism study on inorganic oxidants induced inhibition of Ru(bpy)₃²+ electrochemiluminescence and its application for sensitive determination of some inorganic oxidants.

    PubMed

    Qiu, Bin; Xue, Lingling; Wu, Yanping; Lin, Zhenyu; Guo, Longhua; Chen, Guonan

    2011-07-15

    Inhibited Ru(bpy)(3)(2+) electrochemiluminescence by inorganic oxidants is investigated. Results showed that a number of inorganic oxidants can quench the ECL of Ru(bpy)(3)(2+)/tri-n-propylamine (TPrA) system, and the logarithm of the decrease in ECL intensity (ΔI) was proportional to the logarithm of analyte concentrations. Based on which, a sensitive approach for detection of these inorganic oxidants was established, e.g. the log-log plots of ΔI versus the concentration of MnO(4)(-), Cr(2)O(7)(2-) and Fe(CN)(6)(3-) are linear in the range of 1×10(-7) to 3×10(-4)M for MnO(4)(-) and Cr(2)O(7)(2-), and 1×10(-7) to 1×10(-4)M for Fe(CN)(6)(3-), with the limit of detection (LOD) of 8.0×10(-8)M, 2×10(-8)M, and 1×10(-8)M, respectively. A series of experiments such as a comparison of the inhibitory effect of different compounds on Ru(bpy)(3)(2+)/TPrA ECL, ECL emission spectra, UV-Vis absorption spectra etc. were investigated in order to discover how these inorganic analytes quench the ECL of Ru(bpy)(3)(2+)/TPrA system. A mechanism based on consumption of TPrA intermediate (TPrA(·)) by inorganic oxidants was proposed. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. DNA quantification of basidiomycetous fungi during storage of logging residues

    PubMed Central

    Alfredsen, Gry; Filbakk, Tore; Fossdal, Carl Gunnar

    2015-01-01

    The demand for bioenergy caused an increased use of logging residues, branches and treetops that were previously left on the ground after harvesting. Residues are stored outdoors in piles and it is unclear to what extent fungi transform this material. Our objective was to quantify the amount of wood degrading fungi during storage using quantitative real-time PCR (qPCR) to detect basidiomycetous DNA in logging residues, a novel approach in this field. We found that the qPCR method was accurate in quantifying the fungal DNA during storage. As the moisture content of the piled logging residues decreased during the storage period, the fungal DNA content also decreased. Scots pine residues contained more fungal DNA than residues from Norway spruce. Loose piles had generally more fungal DNA than bundled ones. PMID:25870777

  8. Validity, Responsiveness, Minimal Detectable Change, and Minimal Clinically Important Change of the Pediatric Motor Activity Log in Children with Cerebral Palsy

    ERIC Educational Resources Information Center

    Lin, Keh-chung; Chen, Hui-fang; Chen, Chia-ling; Wang, Tien-ni; Wu, Ching-yi; Hsieh, Yu-wei; Wu, Li-ling

    2012-01-01

    This study examined criterion-related validity and clinimetric properties of the Pediatric Motor Activity Log (PMAL) in children with cerebral palsy. Study participants were 41 children (age range: 28-113 months) and their parents. Criterion-related validity was evaluated by the associations between the PMAL and criterion measures at baseline and…

  9. Chemical logging of geothermal wells

    DOEpatents

    Allen, C.A.; McAtee, R.E.

    The presence of geothermal aquifers can be detected while drilling in geothermal formations by maintaining a chemical log of the ratio of the concentrations of calcium to carbonate and bicarbonate ions in the return drilling fluid. A continuous increase in the ratio of the concentrations of calcium to carbonate and bicarbonate ions is indicative of the existence of a warm or hot geothermal aquifer at some increased depth.

  10. Chemical logging of geothermal wells

    DOEpatents

    Allen, Charles A.; McAtee, Richard E.

    1981-01-01

    The presence of geothermal aquifers can be detected while drilling in geothermal formations by maintaining a chemical log of the ratio of the concentrations of calcium to carbonate and bicarbonate ions in the return drilling fluid. A continuous increase in the ratio of the concentrations of calcium to carbonate and bicarbonate ions is indicative of the existence of a warm or hot geothermal aquifer at some increased depth.

  11. Line-driven disc wind model for ultrafast outflows in active galactic nuclei - scaling with luminosity

    NASA Astrophysics Data System (ADS)

    Nomura, M.; Ohsuga, K.

    2017-03-01

    In order to reveal the origin of the ultrafast outflows (UFOs) that are frequently observed in active galactic nuclei (AGNs), we perform two-dimensional radiation hydrodynamics simulations of the line-driven disc winds, which are accelerated by the radiation force due to the spectral lines. The line-driven winds are successfully launched for the range of MBH = 106-9 M⊙ and ε = 0.1-0.5, and the resulting mass outflow rate (dot{M_w}), momentum flux (dot{p_w}), and kinetic luminosity (dot{E_w}) are in the region containing 90 per cent of the posterior probability distribution in the dot{M}_w-Lbol plane, dot{p}_w-Lbol plane, and dot{E}_w-Lbol plane shown in Gofford et al., where MBH is the black hole mass, ε is the Eddington ratio, and Lbol is the bolometric luminosity. The best-fitting relations in Gofford et al., d log dot{M_w}/d log {L_bol}˜ 0.9, d log dot{p_w}/d log {L_bol}˜ 1.2, and d log dot{E_w}/d log {L_bol}˜ 1.5, are roughly consistent with our results, d log dot{M_w}/d log {L_bol}˜ 9/8, d log dot{p_w}/d log {L_bol}˜ 10/8, and d log dot{E_w}/d log {L_bol}˜ 11/8. In addition, our model predicts that no UFO features are detected for the AGNs with ε ≲ 0.01, since the winds do not appear. Also, only AGNs with MBH ≲ 108 M⊙ exhibit the UFOs when ε ∼ 0.025. These predictions nicely agree with the X-ray observations. These results support that the line-driven disc wind is the origin of the UFOs.

  12. Assessment of the Technical Training Received by Source Selection Participants in Air Force Systems Command.

    DTIC Science & Technology

    1986-09-01

    60 48.4 Systems 200/400 15 12.1 Contract Administration (PPM 152) 13 10.5 Logistics Management (Log 224) 2 1.6 Government Contract Law (PPM 302) 20...detail. 1. Systems 200/400 2. Contract Administration (PPM 152) 3. Logistics Management (LOG 224) 4. Government Contract Law (PPM 302) 5. Technical...152 Contract Administration o Log 224 Logistics Management o PPM 302 Government Contract Law o QMT 345 Quantitative Technical, Cost, and Price Analysis

  13. The development of a full-digital and networkable multi-media based highway information system : phase 1

    DOT National Transportation Integrated Search

    1999-07-26

    This report covers the development of a Multimedia Based Highway Information System (MMHIS). MMHIS extends the capabilities of current photo logging facilities. Photographic logging systems used by highway agencies provide engineers with information ...

  14. The CCD/Transit Instrument (CTI) data-analysis system

    NASA Technical Reports Server (NTRS)

    Cawson, M. G. M.; Mcgraw, J. T.; Keane, M. J.

    1995-01-01

    The automated software system for archiving, analyzing, and interrogating data from the CCD/Transit Instrument (CTI) is described. The CTI collects up to 450 Mbytes of image-data each clear night in the form of a narrow strip of sky observed in two colors. The large data-volumes and the scientific aims of the project make it imperative that the data are analyzed within the 24-hour period following the observations. To this end a fully automatic and self evaluating software system has been developed. The data are collected from the telescope in real-time and then transported to Tucson for analysis. Verification is performed by visual inspection of random subsets of the data and obvious cosmic rays are detected and removed before permanent archival is made to the optical disc. The analysis phase is performed by a pair of linked algorithms, one operating on the absolute pixel-values and the other on the spatial derivative of the data. In this way both isolated and merged images are reliably detected in a single pass. In order to isolate the latter algorithm from the effects of noise spikes a 3x3 Hanning filter is applied to the raw data before the analysis is run. The algorithms reduce the input pixel-data to a database of measured parameters for each image which has been found. A contrast filter is applied in order to assign a detection-probability to each image and then x-y calibration and intensity calibration are performed using known reference stars in the strip. These are added to as necessary by secondary standards boot-strapped from the CTI data itself. The final stages involve merging the new data into the CTI Master-list and History-list and the automatic comparison of each new detection with a set of pre-defined templates in parameter-space to find interesting objects such as supernovae, quasars and variable stars. Each stage of the processing from verification to interesting image selection is performed under a data-logging system which both controls the pipe-lining of data through the system and records key performance monitor parameters which are built into the software. Furthermore, the data from each stage are stored in databases to facilitate evaluation, and all stages offer the facility to enter keyword-indexed free-format text into the data-logging system. In this way a large measure of certification is built into the system to provide the necessary confidence in the end results.

  15. Odor, gaseous and PM10 emissions from small scale combustion of wood types indigenous to Central Europe

    NASA Astrophysics Data System (ADS)

    Kistler, Magdalena; Schmidl, Christoph; Padouvas, Emmanuel; Giebl, Heinrich; Lohninger, Johann; Ellinger, Reinhard; Bauer, Heidi; Puxbaum, Hans

    2012-05-01

    In this study, we investigated the emissions, including odor, from log wood stoves, burning wood types indigenous to mid-European countries such as Austria, Czech Republic, Hungary, Slovak Republic, Slovenia, Switzerland, as well as Baden-Württemberg and Bavaria (Germany) and South Tyrol (Italy). The investigations were performed with a modern, certified, 8 kW, manually fired log wood stove, and the results were compared to emissions from a modern 9 kW pellet stove. The examined wood types were deciduous species: black locust, black poplar, European hornbeam, European beech, pedunculate oak (also known as “common oak”), sessile oak, turkey oak and conifers: Austrian black pine, European larch, Norway spruce, Scots pine, silver fir, as well as hardwood briquettes. In addition, “garden biomass” such as pine cones, pine needles and dry leaves were burnt in the log wood stove. The pellet stove was fired with softwood pellets. The composite average emission rates for log wood and briquettes were 2030 mg MJ-1 for CO; 89 mg MJ-1 for NOx, 311 mg MJ-1 for CxHy, 67 mg MJ-1 for particulate matter PM10 and average odor concentration was at 2430 OU m-3. CO, CxHy and PM10 emissions from pellets combustion were lower by factors of 10, 13 and 3, while considering NOx - comparable to the log wood emissions. Odor from pellets combustion was not detectable. CxHy and PM10 emissions from garden biomass (needles and leaves) burning were 10 times higher than for log wood, while CO and NOx rise only slightly. Odor levels ranged from not detectable (pellets) to around 19,000 OU m-3 (dry leaves). The odor concentration correlated with CO, CxHy and PM10. For log wood combustion average odor ranged from 536 OU m-3 for hornbeam to 5217 OU m-3 for fir, indicating a considerable influence of the wood type on odor concentration.

  16. Integrated system for well-to-well correlation with geological knowledge base

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saito, K.; Doi, E.; Uchiyama, T.

    1987-05-01

    A task of well-to-well correlation is an essential part of the reservoir description study. Since the task is involved with diverse data such as logs, dipmeter, seismic, and reservoir engineering, a system with simultaneous access to such data is desirable. A system is developed to aid stratigraphic correlation under a Xerox 1108 workstation, written in INTERLISP-D. The system uses log, dipmeter, seismic, and computer-processed results such as Litho-Analysis and LSA (Log Shape Analyzer). The system first defines zones which are segmentations of log data into consistent layers using Litho-Analysis and LSA results. Each zone is defined as a minimum unitmore » for correlation with slot values of lithology, thickness, log values, and log shape such as bell, cylinder, and funnel. Using a user's input of local geological knowledge such as depositional environment, the system selects marker beds and performs correlation among the wells chosen from the base map. Correlation is performed first with markers and then with sandstones of lesser lateral extent. Structural dip and seismic horizon are guides for seeking a correlatable event. Knowledge of sand body geometry such as ratio of thickness and width is also used to provide a guide on how far a correlation should be made. Correlation results performed by the system are displayed on the screen for the user to examine and modify. The system has been tested with data sets from several depositional settings and has shown to be a useful tool for correlation work. The results are stored as a data base for structural mapping and reservoir engineering study.« less

  17. Analysis of Hospital Processes with Process Mining Techniques.

    PubMed

    Orellana García, Arturo; Pérez Alfonso, Damián; Larrea Armenteros, Osvaldo Ulises

    2015-01-01

    Process mining allows for discovery, monitoring, and improving processes identified in information systems from their event logs. In hospital environments, process analysis has been a crucial factor for cost reduction, control and proper use of resources, better patient care, and achieving service excellence. This paper presents a new component for event logs generation in the Hospital Information System or HIS, developed at University of Informatics Sciences. The event logs obtained are used for analysis of hospital processes with process mining techniques. The proposed solution intends to achieve the generation of event logs in the system with high quality. The performed analyses allowed for redefining functions in the system and proposed proper flow of information. The study exposed the need to incorporate process mining techniques in hospital systems to analyze the processes execution. Moreover, we illustrate its application for making clinical and administrative decisions for the management of hospital activities.

  18. 12 CFR 27.4 - Inquiry/Application Log.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 1 2011-01-01 2011-01-01 false Inquiry/Application Log. 27.4 Section 27.4... SYSTEM § 27.4 Inquiry/Application Log. (a) The Comptroller, among other things, may require a bank to maintain a Fair Housing Inquiry/Application Log (“Log”), based upon, but not limited to, one or more of the...

  19. 12 CFR 27.4 - Inquiry/Application Log.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Inquiry/Application Log. 27.4 Section 27.4... SYSTEM § 27.4 Inquiry/Application Log. (a) The Comptroller, among other things, may require a bank to maintain a Fair Housing Inquiry/Application Log (“Log”), based upon, but not limited to, one or more of the...

  20. Utilization and cost of log production from animal loging operations

    Treesearch

    Suraj P. Shrestha; Bobby L. Lanford; Robert B. Rummer; Mark Dubois

    2006-01-01

    Forest harvesting with animals is a labor-intensive operation. It is expensive to use machines on smaller woodlots, which require frequent moves if mechanically logged. So, small logging systems using animals may be more cost effective. In this study, work sampling was used for five animal logging operations in Alabama to measure productive and non-productive time...

  1. T-R Cycle Characterization and Imaging: Advanced Diagnostic Methodology for Petroleum Reservoir and Trap Detection and Delineation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ernest A. Mancini

    Characterization of stratigraphic sequences (T-R cycles or sequences) included outcrop studies, well log analysis and seismic reflection interpretation. These studies were performed by researchers at the University of Alabama, Wichita State University and McGill University. The outcrop, well log and seismic characterization studies were used to develop a depositional sequence model, a T-R cycle (sequence) model, and a sequence stratigraphy predictive model. The sequence stratigraphy predictive model developed in this study is based primarily on the modified T-R cycle (sequence) model. The T-R cycle (sequence) model using transgressive and regressive systems tracts and aggrading, backstepping, and infilling intervals or sectionsmore » was found to be the most appropriate sequence stratigraphy model for the strata in the onshore interior salt basins of the Gulf of Mexico to improve petroleum stratigraphic trap and specific reservoir facies imaging, detection and delineation. The known petroleum reservoirs of the Mississippi Interior and North Louisiana Salt Basins were classified using T-R cycle (sequence) terminology. The transgressive backstepping reservoirs have been the most productive of oil, and the transgressive backstepping and regressive infilling reservoirs have been the most productive of gas. Exploration strategies were formulated using the sequence stratigraphy predictive model and the classification of the known petroleum reservoirs utilizing T-R cycle (sequence) terminology. The well log signatures and seismic reflector patterns were determined to be distinctive for the aggrading, backstepping and infilling sections of the T-R cycle (sequence) and as such, well log and seismic data are useful for recognizing and defining potential reservoir facies. The use of the sequence stratigraphy predictive model, in combination with the knowledge of how the distinctive characteristics of the T-R system tracts and their subdivisions are expressed in well log patterns and seismic reflection configurations and terminations, improves the ability to identify and define the limits of potential stratigraphic traps and the stratigraphic component of combination stratigraphic and structural traps and the associated continental, coastal plain and marine potential reservoir facies. The assessment of the underdeveloped and undiscovered reservoirs and resources in the Mississippi Interior and North Louisiana Salt Basins resulted in the confirmation of the Monroe Uplift as a feature characterized by a major regional unconformity, which serves as a combination stratigraphic and structural trap with a significant stratigraphic component, and the characterization of a developing play in southwest Alabama, which involves a stratigraphic trap, located updip near the pinchout of the potential reservoir facies. Potential undiscovered and underdeveloped reservoirs in the onshore interior salt basins are identified as Jurassic and Cretaceous aggrading continental and coastal, backstepping nearshore marine and marine shelf, and infilling fluvial, deltaic, coastal plain and marine shelf.« less

  2. Developing Surveillance Methodology for Agricultural and Logging Injury in New Hampshire Using Electronic Administrative Data Sets.

    PubMed

    Scott, Erika E; Hirabayashi, Liane; Krupa, Nicole L; Sorensen, Julie A; Jenkins, Paul L

    2015-08-01

    Agriculture and logging rank among industries with the highest rates of occupational fatality and injury. Establishing a nonfatal injury surveillance system is a top priority in the National Occupational Research Agenda. Sources of data such as patient care reports (PCRs) and hospitalization data have recently transitioned to electronic databases. Using narrative and location codes from PCRs, along with International Classification of Diseases, 9th Revision, external cause of injury codes (E-codes) in hospital data, researchers are designing a surveillance system to track farm and logging injury. A total of 357 true agricultural or logging cases were identified. These data indicate that it is possible to identify agricultural and logging injury events in PCR and hospital data. Multiple data sources increase catchment; nevertheless, limitations in methods of identification of agricultural and logging injury contribute to the likely undercount of injury events.

  3. A Multi-temporal Analysis of Logging Impacts on Tropical Forest Structure Using Airborne Lidar Data

    NASA Astrophysics Data System (ADS)

    Keller, M. M.; Pinagé, E. R.; Duffy, P.; Longo, M.; dos-Santos, M. N.; Leitold, V.; Morton, D. C.

    2017-12-01

    The long-term impacts of selective logging on carbon cycling and ecosystem function in tropical-forests are still uncertain. Despite improvements in selective logging detection using satellite data, quantifying changes in forest structure from logging and recovery following logging is difficult using orbital data. We analyzed the dynamics of forest structure comparing logged and unlogged forests in the Eastern Brazilian Amazon (Paragominas Municipality, Pará State) using small footprint discrete return airborne lidar data acquired in 2012 and 2014. Logging operations were conducted at the 1200 ha study site from 2006 through 2013 using reduced impact logging techniques—management practices that minimize canopy and ground damage compared to more common conventional logging. Nevertheless, logging still reduced aboveground biomass by 10% to 20% in logged areas compared to intact forests. We aggregated lidar point-cloud data at spatial scales ranging from 50 m to 250 m and developed a binomial classification model based on the height distribution of lidar returns in 2012 and validated the model against the 2014 lidar acquisition. We accurately classified intact and logged forest classes compared with field data. Classification performance improved as spatial resolution increased (AUC = 0.974 at 250 m). We analyzed the differences in canopy gaps, understory damage (based on a relative density model), and biomass (estimated from total canopy height) of intact and logged classes. As expected, logging greatly increased both canopy gap formation and understory damage. However, while the area identified as canopy gap persisted for at least 8 years (from the oldest logging treatments in 2006 to the most recent lidar acquisition in 2014), the effects of ground damage were mostly erased by vigorous understory regrowth after about 5 years. The rate of new gap formation was 6 to 7 times greater in recently logged forests compared to undisturbed forests. New gaps opened at a rate of 1.8 times greater than background even 8 years following logging demonstrating the occurrence of delayed tree mortality. Our study showed that even low-intensity anthropogenic disturbances can cause persistent changes in tropical forest structure and dynamics.

  4. Hydrocarbon potential of pre-Pennsylvanian rocks in Roosevelt County, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pitt, W.D.

    The hydrocarbon potential of pre-Pennsylvanian rocks in Roosevelt County was appraised from data available in published reports, scout tickets, lithology logs, and other well data at the log libraries in Roswell and Socorro, New Mexico, and Midland, Texas. Elevations from lithology logs were used when differing from scout tickets or other sources. Thickness and data other than lithology logs were assumed to be sufficiently accurate if they fitted the control obtained by contouring. The lithology and reservoir potential of the systems of rock that subcrop beneath the Pennsylvanian System in Roosevelt County are summarized.

  5. Integrated analysis of well logs and seismic data to estimate gas hydrate concentrations at Keathley Canyon, Gulf of Mexico

    USGS Publications Warehouse

    Lee, M.W.; Collett, T.S.

    2008-01-01

    Accurately detecting and quantifying gas hydrate or free gas in sediments from seismic data require downhole well-log data to calibrate the physical properties of the gas hydrate-/free gas-bearing sediments. As part of the Gulf of Mexico Joint Industry Program, a series of wells were either cored or drilled in the Gulf of Mexico to characterize the physical properties of gas hydrate-bearing sediments, to calibrate geophysical estimates, and to evaluate source and transport mechanisms for gas within the gas hydrates. Downhole acoustic logs were used sparingly in this study because of degraded log quality due to adverse wellbore conditions. However, reliable logging while drilling (LWD) electrical resistivity and porosity logs were obtained. To tie the well-log information to the available 3-D seismic data in this area, a velocity log was calculated from the available resistivity log at the Keathley Canyon 151-2 well, because the acoustic log or vertical seismic data acquired at the nearby Keathley Canyon 151-3 well were either of poor quality or had limited depth coverage. Based on the gas hydrate saturations estimated from the LWD resistivity log, the modified Biot-Gassmann theory was used to generate synthetic acoustic log and a synthetic seismogram was generated with a fairly good agreement with a seismic profile crossing the well site. Based on the well-log information, a faintly defined bottom-simulating reflection (BSR) in this area is interpreted as a reflection representing gas hydrate-bearing sediments with about 15% saturation overlying partially gas-saturated sediments with 3% saturation. Gas hydrate saturations over 30-40% are estimated from the resistivity log in two distinct intervals at 220-230 and 264-300 m below the sea floor, but gas hydrate was not physically recovered in cores. It is speculated that the poor recovery of cores and gas hydrate morphology are responsible for the lack of physical gas hydrate recovery.

  6. The impact of a personal digital assistant (PDA) case log in a medical student clerkship.

    PubMed

    Ho, Kendall; Lauscher, Helen Novak; Broudo, Marc; Jarvis-Selinger, Sandra; Fraser, Joan; Hewes, Deborah; Scott, Ian

    2009-10-01

    Medical education literature emphasizes that reflection and self-audit are pivotal steps in learning and that personal digital assistants (PDAs) have potential as decision support tools. The purpose was to examine the efficacy of PDA-based resources and patient-encounter logging systems among 3rd-year medical clerks during pediatrics rotations. Students in rotations were assigned to control (using paper-based logs and references) or intervention groups (using PDA-based logs and resources). Students completed pre- and postrotation Paediatrics Competency Surveys, participated in focus groups, and were compared on year-end examination grades. Use of PDA logs far outweighed that of paper logs (1,020 PDA logs and 87 paper logs). PDA logs were ranked significantly higher in enhancing learning and reflection than paper logs (t = 2.52, p < .01). PDA logs also facilitated specific learning experiences. PDA-based patient-encounter logs appear to be effective case documentation and reflection tools. The difference in number of logs between control and intervention groups demonstrates the utility of the PDA for "point-of-care" patient logging.

  7. Warm absorbers in X-rays (WAX), a comprehensive high-resolution grating spectral study of a sample of Seyfert galaxies - I. A global view and frequency of occurrence of warm absorbers.

    NASA Astrophysics Data System (ADS)

    Laha, Sibasish; Guainazzi, Matteo; Dewangan, Gulab C.; Chakravorty, Susmita; Kembhavi, Ajit K.

    2014-07-01

    We present results from a homogeneous analysis of the broad-band 0.3-10 keV CCD resolution as well as of the soft X-ray high-resolution grating spectra of a hard X-ray flux-limited sample of 26 Seyfert galaxies observed with XMM-Newton. Our goal is to characterize warm absorbers (WAs) along the line of sight to the active nucleus. We significantly detect WAs in 65 per cent of the sample sources. Our results are consistent with WAs being present in at least half of the Seyfert galaxies in the nearby Universe, in agreement with previous estimates. We find a gap in the distribution of the ionization parameter in the range 0.5 < log ξ < 1.5 which we interpret as a thermally unstable region for WA clouds. This may indicate that the WA flow is probably constituted by a clumpy distribution of discrete clouds rather than a continuous medium. The distribution of the WA column densities for the sources with broad Fe Kα lines are similar to those sources which do not have broadened emission lines. Therefore, the detected broad Fe Kα emission lines are bona fide and not artefacts of ionized absorption in the soft X-rays. The WA parameters show no correlation among themselves, with the exception of the ionization parameter versus column density. The shallow slope of the log ξ versus log vout linear regression (0.12 ± 0.03) is inconsistent with the scaling laws predicted by radiation or magnetohydrodynamic-driven winds. Our results also suggest that WA and ultra fast outflows do not represent extreme manifestation of the same astrophysical system.

  8. Optimizing Unmanned Aircraft System Scheduling

    DTIC Science & Technology

    2008-06-01

    COL_MISSION_NAME)) If Trim( CStr (rMissions(iRow, COL_MISSION_REQUIRED))) <> "" Then If CLng(rMissions(iRow, COL_MISSION_REQUIRED)) > CLng...logFN, "s:" & CStr (s) & " " For iRow = 1 To top Print #logFN, stack(iRow) & "," Next iRow Print #logFN...340" 60 Print #logFN, "m:" & CStr (s) & " " For iRow = 1 To top Print #logFN, lMissionPeriod(iRow

  9. Use of biopartitioning micellar chromatography and RP-HPLC for the determination of blood-brain barrier penetration of α-adrenergic/imidazoline receptor ligands, and QSPR analysis.

    PubMed

    Vucicevic, J; Popovic, M; Nikolic, K; Filipic, S; Obradovic, D; Agbaba, D

    2017-03-01

    For this study, 31 compounds, including 16 imidazoline/α-adrenergic receptor (IRs/α-ARs) ligands and 15 central nervous system (CNS) drugs, were characterized in terms of the retention factors (k) obtained using biopartitioning micellar and classical reversed phase chromatography (log k BMC and log k wRP , respectively). Based on the retention factor (log k wRP ) and slope of the linear curve (S) the isocratic parameter (φ 0 ) was calculated. Obtained retention factors were correlated with experimental log BB values for the group of examined compounds. High correlations were obtained between logarithm of biopartitioning micellar chromatography (BMC) retention factor and effective permeability (r(log k BMC /log BB): 0.77), while for RP-HPLC system the correlations were lower (r(log k wRP /log BB): 0.58; r(S/log BB): -0.50; r(φ 0 /P e ): 0.61). Based on the log k BMC retention data and calculated molecular parameters of the examined compounds, quantitative structure-permeability relationship (QSPR) models were developed using partial least squares, stepwise multiple linear regression, support vector machine and artificial neural network methodologies. A high degree of structural diversity of the analysed IRs/α-ARs ligands and CNS drugs provides wide applicability domain of the QSPR models for estimation of blood-brain barrier penetration of the related compounds.

  10. Rule Systems for Runtime Verification: A Short Tutorial

    NASA Astrophysics Data System (ADS)

    Barringer, Howard; Havelund, Klaus; Rydeheard, David; Groce, Alex

    In this tutorial, we introduce two rule-based systems for on and off-line trace analysis, RuleR and LogScope. RuleR is a conditional rule-based system, which has a simple and easily implemented algorithm for effective runtime verification, and into which one can compile a wide range of temporal logics and other specification formalisms used for runtime verification. Specifications can be parameterized with data, or even with specifications, allowing for temporal logic combinators to be defined. We outline a number of simple syntactic extensions of core RuleR that can lead to further conciseness of specification but still enabling easy and efficient implementation. RuleR is implemented in Java and we will demonstrate its ease of use in monitoring Java programs. LogScope is a derivation of RuleR adding a simple very user-friendly temporal logic. It was developed in Python, specifically for supporting testing of spacecraft flight software for NASA’s next 2011 Mars mission MSL (Mars Science Laboratory). The system has been applied by test engineers to analysis of log files generated by running the flight software. Detailed logging is already part of the system design approach, and hence there is no added instrumentation overhead caused by this approach. While post-mortem log analysis prevents the autonomous reaction to problems possible with traditional runtime verification, it provides a powerful tool for test automation. A new system is being developed that integrates features from both RuleR and LogScope.

  11. General Multidecision Theory: Hypothesis Testing and Changepoint Detection with Applications to Homeland Security

    DTIC Science & Technology

    2014-10-06

    to a subset Θ̃ of `-dimensional Euclidean space. The sub-σ-algebra Fn = FXn = σ(X n 1 ) of F is generated by the stochastic process X n 1 = (X1...developed asymptotic hypothesis testing theory is based on the SLLN and rates of convergence in the strong law for the LLR processes , specifically by...ξn to C. Write λn(θ, θ̃) = log dPnθ dPn θ̃ = ∑n k=1 log pθ(Xk|Xk−11 ) pθ̃(Xk|X k−1 1 ) for the log-likelihood ratio (LLR) process . Assume that there

  12. Bacteriophages carrying antibiotic resistance genes in fecal waste from cattle, pigs, and poultry.

    PubMed

    Colomer-Lluch, Marta; Imamovic, Lejla; Jofre, Juan; Muniesa, Maite

    2011-10-01

    This study evaluates the occurrence of bacteriophages carrying antibiotic resistance genes in animal environments. bla(TEM), bla(CTX-M) (clusters 1 and 9), and mecA were quantified by quantitative PCR in 71 phage DNA samples from pigs, poultry, and cattle fecal wastes. Densities of 3 to 4 log(10) gene copies (GC) of bla(TEM), 2 to 3 log(10) GC of bla(CTX-M), and 1 to 3 log(10) GC of mecA per milliliter or gram of sample were detected, suggesting that bacteriophages can be environmental vectors for the horizontal transfer of antibiotic resistance genes.

  13. Active Wireline Heave Compensation for Ocean Drilling

    NASA Astrophysics Data System (ADS)

    Goldberg, D.; Liu, T.; Swain, K.; Furman, C.; Iturrino, G. J.

    2014-12-01

    The up-and-down heave motion of a ship causes a similar motion on any instruments tethered on wireline cable below it. If the amplitude of this motion is greater than a few tens of cm, significant discrepancy in the depth below the ship is introduced, causing uncertainty in the acquired data. Large and irregular cabled motions also increase the risk of damaging tethered instruments, particularly those with relatively delicate sensors. In 2005, Schlumberger and Deep Down, Inc built an active wireline heave compensator (AHC) system for use onboard the JOIDES Resolution to compensate for heave motion on wireline logging tools deployed in scientific drill holes. The goals for the new AHC system were to (1) design a reliable heave compensation system; and (2) devise a robust and quantitative methodology for routine assessment of compensation efficiency (CE) during wireline operations. Software programs were developed to monitor CE and the dynamics of logging tools in real-time, including system performance under variable parameters such as water depth, sea state, cable length, logging speed and direction. We present the CE results from the AHC system on the JOIDES Resolution during a 5-year period of recent IODP operations and compare the results to those from previous compensation systems deployed during ODP and IODP. Based on new data under heave conditions of ±0.2-2.0 m and water depths of 300-4,800 m in open holes, the system reduces 65-80% of downhole tool displacement under stationary conditions and 50-60% during normal logging operations. Moreover, down/up tool motion at low speeds (300-600 m/h) reduces the system's CE values by 15-20%, and logging down at higher speeds (1,000-1,200 m/h) reduces CE values by 55-65%. Furthermore, the system yields slightly lower CE values of 40-50% without tension feedback of the downhole cable while logging. These results indicate that the new system's compensation efficiency is comparable to or better than previous systems, with additional advantages that include upgradable compensation control software and the capability for continued assessment under varying environmental conditions. Future integration of downhole cable dynamics as an input feedback could further improve CE during logging operations.­

  14. Viability-qPCR for detecting Legionella: Comparison of two assays based on different amplicon lengths.

    PubMed

    Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M

    2015-08-01

    Two different real-time quantitative PCR (PMA-qPCR) assays were applied for quantification of Legionella spp. by targeting a long amplicon (approx 400 bp) of 16S rRNA gene and a short amplicon (approx. 100 bp) of 5S rRNA gene. Purified DNA extracts from pure cultures of Legionella spp. and from environmental water samples were quantified. Application of the two assays to quantify Legionella in artificially contaminated water achieved that both assays were able to detect Legionella over a linear range of 10 to 10(5) cells ml(-1). A statistical analysis of the standard curves showed that both assays were linear with a good correlation coefficient (R(2) = 0.99) between the Ct and the copy number. Amplification with the reference assay was the most effective for detecting low copy numbers (1 bacterium per PCR mixture). Using selective quantification of viable Legionella by the PMA-qPCR method we obtained a greater inhibition of the amplification of the 400-bp 16S gene fragment (Δlog(10) = 3.74 ± 0.39 log(10) GU ml(-1)). A complete inhibition of the PCR signal was obtained when heat-killed cells in a concentration below 1 × 10(5) cells ml(-1) were pretreated with PMA. Analysing short amplicon sizes led to only 2.08 log reductions in the Legionella dead-cell signal. When we tested environmental water samples, the two qPCR assays were in good agreement according to the kappa index (0.741). Applying qPCR combined with PMA treatment, we also obtained a good agreement (kappa index 0.615). The comparison of quantitative results shows that both assays yielded the same quantification sensitivity (mean log = 4.59 vs mean log = 4.31). Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Changes in the Microbial Composition of Microbrewed Beer during the Process in the Actual Manufacturing Line.

    PubMed

    Kim, S A; Jeon, S H; Kim, N H; Kim, H W; Lee, N Y; Cho, T J; Jung, Y M; Lee, S H; Hwang, I G; Rhee, M S

    2015-12-01

    This study investigated changes in the microbial composition of microbrewed beer during the manufacturing processes and identified potential microbial hazards, effective critical quality control points, and potential contamination routes. Comprehensive quantitative (aerobic plate count, lactic acid bacteria, fungi, acetic acid bacteria, coliforms, and Bacillus cereus) and qualitative (Escherichia coli and eight foodborne pathogens) microbiological analyses were performed using samples of raw materials (malt and manufacturing water), semiprocessed products (saccharified wort, boiled wort, and samples taken during the fermentation and maturation process), and the final product obtained from three plants. The initial aerobic plate count and lactic acid bacteria counts in malt were 5.2 and 4.3 log CFU/g, respectively. These counts were reduced to undetectable levels by boiling but were present at 2.9 and 0.9 log CFU/ml in the final product. Fungi were initially present at 3.6 log CFU/g, although again, the microbes were eliminated by boiling; however, the level in the final product was 4.6 log CFU/ml. No E. coli or foodborne pathogens (except B. cereus) were detected. B. cereus was detected at all stages, although it was not present in the water or boiled wort (total detection rate ¼ 16.4%). Results suggest that boiling of the wort is an effective microbial control measure, but careful management of raw materials and implementation of effective control measures after boiling are needed to prevent contamination of the product after the boiling step. The results of this study may constitute useful and comprehensive information regarding the microbiological quality of microbrewed beer.

  16. 78 FR 21396 - Notice of a Federal Advisory Committee Meeting: Manufactured Housing Consensus Committee...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-10

    ... specifying the permissible scope and conduct of monitoring; and Be organized and carry out its business in a...-12 III. Review Log of Proposal: Log 1 24 CFR 3285--Alternative Foundation System Testing. Log 80 24...-fhydelarge.html ; Video explaining ASTM D6007: http://www.ntainc.com/video-fhyde.html . Log 81 24 CFR 3280...

  17. Tree damage from skyline logging in a western larch/Douglas-fir stand

    Treesearch

    Robert E. Benson; Michael J. Gonsior

    1981-01-01

    Damage to shelterwood leave trees and to understory trees in shelterwood and clearcut logging units logged with skyline yarders was measured, and related to stand conditions, harvesting specifications, and yarding system-terrain interactions. About 23 percent of the marked leave trees in the shelterwood units were killed in logging, and about 10 percent had moderate to...

  18. Performance of the New Aptima HCV Quant Dx Assay in Comparison to the Cobas TaqMan HCV2 Test for Use with the High Pure System in Detection and Quantification of Hepatitis C Virus RNA in Plasma or Serum.

    PubMed

    Schalasta, Gunnar; Speicher, Andrea; Börner, Anna; Enders, Martin

    2016-04-01

    Quantitating the level of hepatitis C virus (HCV) RNA is the standard of care for monitoring HCV-infected patients during treatment. The performances of commercially available assays differ for precision, limit of detection, and limit of quantitation (LOQ). Here, we compare the performance of the Hologic Aptima HCV Quant Dx assay (Aptima) to that of the Roche Cobas TaqMan HCV test, version 2.0, using the High Pure system (HPS/CTM), considered a reference assay since it has been used in trials defining clinical decision points in patient care. The assays' performance characteristics were assessed using HCV RNA reference panels and plasma/serum from chronically HCV-infected patients. The agreement between the assays for the 3 reference panels was good, with a difference in quantitation values of <0.5 log. High concordance was demonstrated between the assays for 245 clinical samples (kappa = 0.80; 95% confidence interval [CI], 0.720 to 0.881); however, Aptima detected and/or quantitated 20 samples that HPS/CTM did not detect, while Aptima did not detect 1 sample that was quantitated by HPS/CTM. For the 165 samples quantitated by both assays, the values were highly correlated (R= 0.98;P< 0.0001). The linearity of quantitation from concentrations of 1.4 to 6 log was excellent for both assays for all HCV genotypes (GT) tested (GT 1a, 1b, 2b, and 3a) (R(2)> 0.99). The assays had similar levels of total and intra-assay variability across all genotypes at concentrations from 1,000 to 25 IU/ml. Aptima had a greater analytical sensitivity, quantitating more than 50% of replicates at 25-IU/ml target. Aptima showed performance characteristics comparable to those of HPS/CTM and increased sensitivity, making it suitable for use as a clinical diagnostic tool on the fully automated Panther platform. Copyright © 2016 Schalasta et al.

  19. Comprehensive Evaluation of the MBT STAR-BL Module for Simultaneous Bacterial Identification and β-Lactamase-Mediated Resistance Detection in Gram-Negative Rods from Cultured Isolates and Positive Blood Cultures.

    PubMed

    Lee, Annie W T; Lam, Johnson K S; Lam, Ricky K W; Ng, Wan H; Lee, Ella N L; Lee, Vicky T Y; Sze, Po P; Rajwani, Rahim; Fung, Kitty S C; To, Wing K; Lee, Rodney A; Tsang, Dominic N C; Siu, Gilman K H

    2018-01-01

    Objective: This study evaluated the capability of a MALDI Biotyper system equipped with the newly introduced MBT STAR-BL module to simultaneously perform species identification and β-lactamase-mediated resistance detection in bacteremia -causing bacteria isolated from cultured isolates and patient-derived blood cultures (BCs). Methods: Two hundred retrospective cultured isolates and 153 prospective BCs containing Gram-negative rods (GNR) were collected and subjected to direct bacterial identification, followed by the measurement of β-lactamase activities against ampicillin, piperacillin, cefotaxime, ceftazidime, and meropenem using the MBT STAR-BL module. The results and turnaround times were compared with those of routine microbiological processing. All strains were also characterized by beta-lactamase PCR and sequencing. Results: Using the saponin-based extraction method, MALDI-TOF MS correctly identified bacteria in 116/134 (86.6%) monomicrobial BCs. The detection sensitivities for β-lactamase activities against ampicillin, piperacillin, third-generation cephalosporin and meropenem were 91.3, 100, 97.9, and 100% for cultured isolates, and 80.4, 100, 68.8, and 40% for monomicrobial BCs ( n = 134) respectively. The overall specificities ranged from 91.5 to 100%. Furthermore, the MBT STAR-BL and conventional drug susceptibility test results were concordant in 14/19 (73.7%) polymicrobial cultures. Reducing the logRQ cut-off value from 0.4 to 0.2 increased the direct detection sensitivities for β-lactamase activities against ampicillin, cefotaxime and meropenem in BCs to 85.7, 87.5, and 100% respectively. The MBT STAR-BL test enabled the reporting of β-lactamase-producing GNR at 14.16 and 47.64 h before the interim and final reports of routine BCs processing, respectively, were available. Conclusion: The MALDI Biotyper system equipped with the MBT STAR-BL module enables the simultaneous rapid identification of bacterial species and β-lactamase-mediated resistance from BCs and cultured isolates. Adjustment of the logRQ cut-off value to 0.2 significantly increased the detection sensitivities for clinically important drug-resistant pathogens.

  20. Comprehensive Evaluation of the MBT STAR-BL Module for Simultaneous Bacterial Identification and β-Lactamase-Mediated Resistance Detection in Gram-Negative Rods from Cultured Isolates and Positive Blood Cultures

    PubMed Central

    Lee, Annie W. T.; Lam, Johnson K. S.; Lam, Ricky K. W.; Ng, Wan H.; Lee, Ella N. L.; Lee, Vicky T. Y.; Sze, Po P.; Rajwani, Rahim; Fung, Kitty S. C.; To, Wing K.; Lee, Rodney A.; Tsang, Dominic N. C.; Siu, Gilman K. H.

    2018-01-01

    Objective: This study evaluated the capability of a MALDI Biotyper system equipped with the newly introduced MBT STAR-BL module to simultaneously perform species identification and β-lactamase-mediated resistance detection in bacteremia -causing bacteria isolated from cultured isolates and patient-derived blood cultures (BCs). Methods: Two hundred retrospective cultured isolates and 153 prospective BCs containing Gram-negative rods (GNR) were collected and subjected to direct bacterial identification, followed by the measurement of β-lactamase activities against ampicillin, piperacillin, cefotaxime, ceftazidime, and meropenem using the MBT STAR-BL module. The results and turnaround times were compared with those of routine microbiological processing. All strains were also characterized by beta-lactamase PCR and sequencing. Results: Using the saponin-based extraction method, MALDI-TOF MS correctly identified bacteria in 116/134 (86.6%) monomicrobial BCs. The detection sensitivities for β-lactamase activities against ampicillin, piperacillin, third-generation cephalosporin and meropenem were 91.3, 100, 97.9, and 100% for cultured isolates, and 80.4, 100, 68.8, and 40% for monomicrobial BCs (n = 134) respectively. The overall specificities ranged from 91.5 to 100%. Furthermore, the MBT STAR-BL and conventional drug susceptibility test results were concordant in 14/19 (73.7%) polymicrobial cultures. Reducing the logRQ cut-off value from 0.4 to 0.2 increased the direct detection sensitivities for β-lactamase activities against ampicillin, cefotaxime and meropenem in BCs to 85.7, 87.5, and 100% respectively. The MBT STAR-BL test enabled the reporting of β-lactamase-producing GNR at 14.16 and 47.64 h before the interim and final reports of routine BCs processing, respectively, were available. Conclusion: The MALDI Biotyper system equipped with the MBT STAR-BL module enables the simultaneous rapid identification of bacterial species and β-lactamase-mediated resistance from BCs and cultured isolates. Adjustment of the logRQ cut-off value to 0.2 significantly increased the detection sensitivities for clinically important drug-resistant pathogens. PMID:29527202

  1. Gulf of Mexico Gas Hydrate Joint Industry Project Leg II logging-while-drilling data acquisition and analysis

    USGS Publications Warehouse

    Collett, Timothy S.; Lee, Wyung W.; Zyrianova, Margarita V.; Mrozewski, Stefan A.; Guerin, Gilles; Cook, Ann E.; Goldberg, Dave S.

    2012-01-01

    One of the objectives of the Gulf of Mexico Gas Hydrate Joint Industry Project Leg II (GOM JIP Leg II) was the collection of a comprehensive suite of logging-while-drilling (LWD) data within gas-hydrate-bearing sand reservoirs in order to make accurate estimates of the concentration of gas hydrates under various geologic conditions and to understand the geologic controls on the occurrence of gas hydrate at each of the sites drilled during this expedition. The LWD sensors just above the drill bit provided important information on the nature of the sediments and the occurrence of gas hydrate. There has been significant advancements in the use of downhole well-logging tools to acquire detailed information on the occurrence of gas hydrate in nature: From using electrical resistivity and acoustic logs to identify gas hydrate occurrences in wells to where wireline and advanced logging-while-drilling tools are routinely used to examine the petrophysical nature of gas hydrate reservoirs and the distribution and concentration of gas hydrates within various complex reservoir systems. Recent integrated sediment coring and well-log studies have confirmed that electrical resistivity and acoustic velocity data can yield accurate gas hydrate saturations in sediment grain supported (isotropic) systems such as sand reservoirs, but more advanced log analysis models are required to characterize gas hydrate in fractured (anisotropic) reservoir systems. In support of the GOM JIP Leg II effort, well-log data montages have been compiled and presented in this report which includes downhole logs obtained from all seven wells drilled during this expedition with a focus on identifying and characterizing the potential gas-hydrate-bearing sedimentary section in each of the wells. Also presented and reviewed in this report are the gas-hydrate saturation and sediment porosity logs for each of the wells as calculated from available downhole well logs.

  2. Log-less metadata management on metadata server for parallel file systems.

    PubMed

    Liao, Jianwei; Xiao, Guoqiang; Peng, Xiaoning

    2014-01-01

    This paper presents a novel metadata management mechanism on the metadata server (MDS) for parallel and distributed file systems. In this technique, the client file system backs up the sent metadata requests, which have been handled by the metadata server, so that the MDS does not need to log metadata changes to nonvolatile storage for achieving highly available metadata service, as well as better performance improvement in metadata processing. As the client file system backs up certain sent metadata requests in its memory, the overhead for handling these backup requests is much smaller than that brought by the metadata server, while it adopts logging or journaling to yield highly available metadata service. The experimental results show that this newly proposed mechanism can significantly improve the speed of metadata processing and render a better I/O data throughput, in contrast to conventional metadata management schemes, that is, logging or journaling on MDS. Besides, a complete metadata recovery can be achieved by replaying the backup logs cached by all involved clients, when the metadata server has crashed or gone into nonoperational state exceptionally.

  3. Log-Less Metadata Management on Metadata Server for Parallel File Systems

    PubMed Central

    Xiao, Guoqiang; Peng, Xiaoning

    2014-01-01

    This paper presents a novel metadata management mechanism on the metadata server (MDS) for parallel and distributed file systems. In this technique, the client file system backs up the sent metadata requests, which have been handled by the metadata server, so that the MDS does not need to log metadata changes to nonvolatile storage for achieving highly available metadata service, as well as better performance improvement in metadata processing. As the client file system backs up certain sent metadata requests in its memory, the overhead for handling these backup requests is much smaller than that brought by the metadata server, while it adopts logging or journaling to yield highly available metadata service. The experimental results show that this newly proposed mechanism can significantly improve the speed of metadata processing and render a better I/O data throughput, in contrast to conventional metadata management schemes, that is, logging or journaling on MDS. Besides, a complete metadata recovery can be achieved by replaying the backup logs cached by all involved clients, when the metadata server has crashed or gone into nonoperational state exceptionally. PMID:24892093

  4. Microbial removals by a novel biofilter water treatment system.

    PubMed

    Wendt, Christopher; Ives, Rebecca; Hoyt, Anne L; Conrad, Ken E; Longstaff, Stephanie; Kuennen, Roy W; Rose, Joan B

    2015-04-01

    Two point-of-use drinking water treatment systems designed using a carbon filter and foam material as a possible alternative to traditional biosand systems were evaluated for removal of bacteria, protozoa, and viruses. Two configurations were tested: the foam material was positioned vertically around the carbon filter in the sleeve unit or horizontally in the disk unit. The filtration systems were challenged with Cryptosporidium parvum, Raoultella terrigena, and bacteriophages P22 and MS2 before and after biofilm development to determine average log reduction (ALR) for each organism and the role of the biofilm. There was no significant difference in performance between the two designs, and both designs showed significant levels of removal (at least 4 log10 reduction in viruses, 6 log10 for protozoa, and 8 log10 for bacteria). Removal levels meet or exceeded Environmental Protection Agency (EPA) standards for microbial purifiers. Exploratory test results suggested that mature biofilm formation contributed 1-2 log10 reductions. Future work is recommended to determine field viability. © The American Society of Tropical Medicine and Hygiene.

  5. Integration of QR codes into an anesthesia information management system for resident case log management.

    PubMed

    Avidan, Alexander; Weissman, Charles; Levin, Phillip D

    2015-04-01

    Quick response (QR) codes containing anesthesia syllabus data were introduced into an anesthesia information management system. The code was generated automatically at the conclusion of each case and available for resident case logging using a smartphone or tablet. The goal of this study was to evaluate the use and usability/user-friendliness of such system. Resident case logging practices were assessed prior to introducing the QR codes. QR code use and satisfactions amongst residents was reassessed at three and six months. Before QR code introduction only 12/23 (52.2%) residents maintained a case log. Most of the remaining residents (9/23, 39.1%) expected to receive a case list from the anesthesia information management system database at the end of their residency. At three months and six months 17/26 (65.4%) and 15/25 (60.0%) residents, respectively, were using the QR codes. Satisfaction was rated as very good or good. QR codes for residents' case logging with smartphones or tablets were successfully introduced in an anesthesia information management system and used by most residents. QR codes can be successfully implemented into medical practice to support data transfer. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Improvement of mannitol-yolk-polymyxin B agar by supplementing with trimethoprim for quantitative detection of Bacillus cereus in foods.

    PubMed

    Chon, Jung-Whan; Hyeon, Ji-Yeon; Park, Jun-Ho; Song, Kwang-Young; Kim, Jong-Hyun; Seo, Kun-Ho

    2012-07-01

    Mannitol-yolk-polymyxin B agar (MYPA) was modified by supplementation with trimethoprim. The ability of the supplemented medium to select for and recover Bacillus cereus from pure cultures and food samples with high background microflora was compared with MYPA. For evaluation of the modified MYPA (mMYPA) in food samples with high background microflora, B. cereus was experimentally spiked into red pepper powder, fermented soybean paste, vegetable salad, and radish sprouts, and then it was recovered on MYPA and mMYPA for comparison. In all food samples, there was no difference in recoverability (P > 0.05) between mMYPA (red pepper powder, 3.34 ± 0.24 log CFU/g; fermented soybean paste, 3.52 ± 0.47 log CFU/g; vegetable salad, 3.51 ± 0.23 log CFU/g; radish sprouts, 3.32 ± 0.40 log CFU/g) and MYPA (red pepper powder, 3.18 ± 0.20 log CFU/g; fermented soybean paste, 3.33 ± 0.43 log CFU/g; vegetable salad, 3.36 ± 0.19 log CFU/g; radish sprouts, 3.33 ± 0.31 log CFU/g). However, mMYPA exhibited better selectivity than MYPA, because additional trimethoprim made the differentiation of suspected colonies easier by inhibiting competing flora. The addition of trimethoprim to conventional media could be a useful option to improve selectivity in foods with high background microflora.

  7. Hierarchical Bayesian calibration of tidal orbit decay rates among hot Jupiters

    NASA Astrophysics Data System (ADS)

    Collier Cameron, Andrew; Jardine, Moira

    2018-05-01

    Transiting hot Jupiters occupy a wedge-shaped region in the mass ratio-orbital separation diagram. Its upper boundary is eroded by tidal spiral-in of massive, close-in planets and is sensitive to the stellar tidal dissipation parameter Q_s^'. We develop a simple generative model of the orbital separation distribution of the known population of transiting hot Jupiters, subject to tidal orbital decay, XUV-driven evaporation and observational selection bias. From the joint likelihood of the observed orbital separations of hot Jupiters discovered in ground-based wide-field transit surveys, measured with respect to the hyperparameters of the underlying population model, we recover narrow posterior probability distributions for Q_s^' in two different tidal forcing frequency regimes. We validate the method using mock samples of transiting planets with known tidal parameters. We find that Q_s^' and its temperature dependence are retrieved reliably over five orders of magnitude in Q_s^'. A large sample of hot Jupiters from small-aperture ground-based surveys yields log _{10} Q_s^' }=(8.26± 0.14) for 223 systems in the equilibrium-tide regime. We detect no significant dependence of Q_s^' on stellar effective temperature. A further 19 systems in the dynamical-tide regime yield log _{10} Q_s^' }=7.3± 0.4, indicating stronger coupling. Detection probabilities for transiting planets at a given orbital separation scale inversely with the increase in their tidal migration rates since birth. The resulting bias towards younger systems explains why the surface gravities of hot Jupiters correlate with their host stars' chromospheric emission fluxes. We predict departures from a linear transit-timing ephemeris of less than 4 s for WASP-18 over a 20-yr baseline.

  8. A study on directional resistivity logging-while-drilling based on self-adaptive hp-FEM

    NASA Astrophysics Data System (ADS)

    Liu, Dejun; Li, Hui; Zhang, Yingying; Zhu, Gengxue; Ai, Qinghui

    2014-12-01

    Numerical simulation of resistivity logging-while-drilling (LWD) tool response provides guidance for designing novel logging instruments and interpreting real-time logging data. In this paper, based on self-adaptive hp-finite element method (hp-FEM) algorithm, we analyze LWD tool response against model parameters and briefly illustrate geosteering capabilities of directional resistivity LWD. Numerical simulation results indicate that the change of source spacing is of obvious influence on the investigation depth and detecting precision of resistivity LWD tool; the change of frequency can improve the resolution of low-resistivity formation and high-resistivity formation. The simulation results also indicate that the self-adaptive hp-FEM algorithm has good convergence speed and calculation accuracy to guide the geologic steering drilling and it is suitable to simulate the response of resistivity LWD tools.

  9. Control of Cryptosporidium with wastewater treatment to prevent its proliferation in the water cycle.

    PubMed

    Suwa, M; Suzuki, Y

    2003-01-01

    The outbreak of Cryptosporidiosis in 1996 in Japan is thought to have been enlarged by the proliferation of Cryptosporidium in the water cycle from wastewater to drinking water through the river system. From this experience, the wastewater system must have functions to remove Cryptosporidium oocysts effectively. Efficiencies of wastewater treatment processes to remove oocysts were investigated using pilot plants receiving municipal wastewater. An activated sludge process and a following sand filter showed removal efficiencies of 2 log and 0.5 log, respectively. Poly-aluminium chloride dosage improved the efficiencies by 3 log for the activated sludge process and by 2 log for the sand filter. Chemical precipitation of raw wastewater with poly-aluminium chloride could achieve 1 to 3 log removal according on the coagulant concentration.

  10. Integrating Multiple Subsurface Exploration Technologies in Slope Hydrogeologic Investigation: A Case Study in Taiwan

    NASA Astrophysics Data System (ADS)

    Lo, H.-C.; Hsu, S.-M.; Jeng, D.-I.; Ku, C.-Y.

    2009-04-01

    Taiwan is an island located at a tectonically active collision zone between the Eurasian Plate and the Pacific Plate. Also, the island is in the subtropical climate region with frequent typhoon events that are always accompanied by intense rainfalls within a short period of time. These seismic and climatic elements frequently trigger, directly or indirectly, natural disasters such as landslides on the island with casualties and property damages. Prompted by the urge for minimizing the detrimental effects of such natural disasters, Taiwan government has initiated and funded a series of investigations and studies aimed at better understanding the causes of the natural disasters that may lead to the formulation of more effective disaster contingency plans and possibly some forecasts system. The hydrogeology of a landslide site can help unveil the detention condition of storm water entering the aquifer system of the slope as well as its groundwater condition which, in turn, plays a critical role in slope stability. In this study, a hydrogeologic investigation employing a series of subsurface exploration technologies was conducted at an active landslide site in the vicinity of Hwa Yuan Village in northern Taiwan. The site, which covers an area of approximately 0.14 km2 (35 acres) and generally ranges between 25 to 36 degree in slope, was initially investigated with ground resistivity image profiling (RIP) and electrical logging in order to determine the lithology and possibly the water-bearing capacity of the geologic units beneath the slope surface. Subsequently, both acoustic and optical borehole loggings were then applied to identify potentially significant fracture features at depth and their hydrogeologic implications. In addition, flowmeter loggings and hydraulic packer tests were conducted to further characterize the hydrogeologic system of the site and quantitatively determine the hydraulic properties of major hydrogeologic units. According to the ground resistivity profiles combined with rock core data, the geologic units can be primarily categorized into colluvium and weathered rock at depths of 4-23 m and 23-80 m, respectively. An approximately 20 m shear zone at depths of 45-65 m was found based on the detection outcome of low electrical resistance. Also, according to the borehole electrical logging, the layer of sandstone was identified in the interval of 48-59 m and 68.5-74 m and showed low water-bearing capacity. In addition, the electrical logging identified the layer of shale was in the interval of 59-68.5 m, which possessed a high water-bearing capacity. The velocity profile along the borehole was obtained from the flowmeter logging. A relatively high velocity zone (1.36~2.23 m/min) was measured in the interval of sandstone and relatively low velocity zone (0.12~0.78 m/min) was measured in the interval of shale, which is similar to those found in electrical logging. Moreover, 198 discontinuity planes were identified from the borehole image logging. The orientations of all discontinuities were calculated and compiled to draw a stereographic projection diagram. Judging from the discontinuity clusters on the stereographic projection diagram, a plane failure may possibly occur based on Hoek and Brown's criteria. This is a good demonstration that slope failure geometry and type can be determined by stereographic projection diagram analysis. The borehole images also clearly showed the structures of discontinuities at depth. They not only helped to characterize the results of the above investigation technologies but also provided useful indication in selecting specific geologic intervals for packer tests. The packer tests were conducted and the intervals were isolated based on the results of borehole and flowmeter logging. They indicated that the hydraulic conductivities of the shale and sandstone intervals are respectively 1.37Ã-10-8 m/sec and 2.68Ã-10-5-3.76Ã-10-5 m/sec, which are in good accordance with the hydraulic characteristics inferred by flowmeter logging. The aforementioned investigation results, including the geology units and water-bearing capacity categorized by RIP and electrical logging, velocity and hydraulic conductivity obtained from flowmeter logging and packer test, and discontinuity structures recorded by borehole image logging, were used to clarify the complexity of the subsurface environment and to establish the hydrogeologic conceptual model of the landslide site.

  11. An Empirical Comparison of DDF Detection Methods for Understanding the Causes of DIF in Multiple-Choice Items

    ERIC Educational Resources Information Center

    Suh, Youngsuk; Talley, Anna E.

    2015-01-01

    This study compared and illustrated four differential distractor functioning (DDF) detection methods for analyzing multiple-choice items. The log-linear approach, two item response theory-model-based approaches with likelihood ratio tests, and the odds ratio approach were compared to examine the congruence among the four DDF detection methods.…

  12. A Wearable Healthcare System With a 13.7 μA Noise Tolerant ECG Processor.

    PubMed

    Izumi, Shintaro; Yamashita, Ken; Nakano, Masanao; Kawaguchi, Hiroshi; Kimura, Hiromitsu; Marumoto, Kyoji; Fuchikami, Takaaki; Fujimori, Yoshikazu; Nakajima, Hiroshi; Shiga, Toshikazu; Yoshimoto, Masahiko

    2015-10-01

    To prevent lifestyle diseases, wearable bio-signal monitoring systems for daily life monitoring have attracted attention. Wearable systems have strict size and weight constraints, which impose significant limitations of the battery capacity and the signal-to-noise ratio of bio-signals. This report describes an electrocardiograph (ECG) processor for use with a wearable healthcare system. It comprises an analog front end, a 12-bit ADC, a robust Instantaneous Heart Rate (IHR) monitor, a 32-bit Cortex-M0 core, and 64 Kbyte Ferroelectric Random Access Memory (FeRAM). The IHR monitor uses a short-term autocorrelation (STAC) algorithm to improve the heart-rate detection accuracy despite its use in noisy conditions. The ECG processor chip consumes 13.7 μA for heart rate logging application.

  13. Role of photoacoustics in optogalvanics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, D.; McGlynn, S.P.

    1990-09-15

    Time-resolved laser optogalvanic (LOG) signals have been induced by pulsed laser excitation (l{ital s}{sub {ital j}}{r arrow}2{ital p}{sub {ital k}}, Paschen notation) of a {approximately}30 MHz radio-frequency (rf) discharge in neon at {approximately}5 torr. Dramatic changes of the shape/polarity of certain parts of the LOG signals occur when the rf excitation frequency is scanned over the electrical resonance peak of the plasma and the associated driving/detecting circuits. These effects are attributed to ionization rate changes (i.e., laser-induced alterations of the plasma conductivity), with concomitant variations in the plasma resonance characteristics. In addition to ionization rate changes, it is shown thatmore » photoacoustic (PA) effects also play a significant role in the generation of the LOG signal. Those parts of the LOG signal that are invariant with respect to the rf frequency are attributed to a PA effect. The similarity of LOG signal shapes from both rf and dc discharges suggests that photoacoustics play a similar role in the LOG effect in dc discharges. Contrary to common belief, most reported LOG signal profiles, ones produced by excitation to levels that do not lie close to the ionization threshold, appear to be totally mediated by the PA effect.« less

  14. Transaction Logging.

    ERIC Educational Resources Information Center

    Jones, S.; And Others

    1997-01-01

    Discusses the use of transaction logging in Okapi-related projects to allow search algorithms and user interfaces to be investigated, evaluated, and compared. A series of examples is presented, illustrating logging software for character-based and graphical user interface systems, and demonstrating the usefulness of relational database management…

  15. DIY soundcard based temperature logging system. Part II: applications

    NASA Astrophysics Data System (ADS)

    Nunn, John

    2016-11-01

    This paper demonstrates some simple applications of how temperature logging systems may be used to monitor simple heat experiments, and how the data obtained can be analysed to get some additional insight into the physical processes.

  16. A Study of Dim Object Detection for the Space Surveillance Telescope

    DTIC Science & Technology

    2013-03-21

    ENG-13-M-32 Abstract Current methods of dim object detection for space surveillance make use of a Gaussian log-likelihood-ratio-test-based...quantitatively comparing the efficacy of two methods for dim object detection , termed in this paper the point detector and the correlator, both of which rely... applications . It is used in national defense for detecting satellites. It is used to detecting space debris, which threatens both civilian and

  17. Zone fluidics for measurement of octanol-water partition coefficient of drugs.

    PubMed

    Wattanasin, Panwadee; Saetear, Phoonthawee; Wilairat, Prapin; Nacapricha, Duangjai; Teerasong, Saowapak

    2015-02-20

    A novel zone fluidics (ZF) system for the determination of the octanol-water partition coefficient (Pow) of drugs was developed. The ZF system consisted of a syringe pump with a selection valve, a holding column, a silica capillary flow-cell and an in-line spectrophotometer. Exact microliter volumes of solvents (octanol and phosphate buffer saline) and a solution of the drug, sandwiched between air segments, were sequentially loaded into the vertically aligned holding column. Distribution of the drug between the aqueous and octanol phases occurred by the oscillation movement of the syringe pump piston. Phase separation occurred due to the difference in densities. The liquid zones were then pushed into the detection flow cell. In this method, absorbance measurements in only one of the phase (octanol or aqueous) were employed, which together with the volumes of the solvents and pure drug sample, allowed the calculation of the Pow. The developed system was applied to the determination of the Pow of some common drugs. The log (Pow) values agreed well with a batch method (R(2)=0.999) and literature (R(2)=0.997). Standard deviations for intra- and inter-day analyses were both less than 0.1log unit. This ZF system provides a robust and automated method for screening of Pow values in the drug discovery process. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Decontamination of Bacillus spores adhered to iron and cement-mortar drinking water infrastructure in a model system using disinfectants.

    PubMed

    Szabo, Jeffrey G; Meiners, Greg; Heckman, Lee; Rice, Eugene W; Hall, John

    2017-02-01

    Decontamination of Bacillus spores adhered to common drinking water infrastructure surfaces was evaluated using a variety of disinfectants. Corroded iron and cement-mortar lined iron represented the infrastructure surfaces, and were conditioned in a 23 m long, 15 cm diameter (75 ft long, 6 in diameter) pilot-scale drinking water distribution pipe system. Decontamination was evaluated using increased water velocity (flushing) alone at 0.5 m s -1 (1.7 ft s -1 ), as well as free chlorine (5 and 25 mg L -1 ), monochloramine (25 mg L -1 ), chlorine dioxide (5 and 25 mg L -1 ), ozone (2.0 mg L -1 ), peracetic acid 25 mg L -1 ) and acidified nitrite (0.1 mol L -1 at pH 2 and 3), all followed by flushing at 0.3 m s -1 (1 ft s -1 ). Flushing alone reduced the adhered spores by 0.5 and 2.0 log 10 from iron and cement-mortar, respectively. Log 10 reduction on corroded iron pipe wall coupons ranged from 1.0 to 2.9 at respective chlorine dioxide concentrations of 5 and 25 mg L -1 , although spores were undetectable on the iron surface during disinfection at 25 mg L -1 . Acidified nitrite (pH 2, 0.1 mol L -1 ) yielded no detectable spores on the iron surface during the flushing phase after disinfection. Chlorine dioxide was the best performing disinfectant with >3.0 log 10 removal from cement-mortar at 5 and 25 mg L -1 . The data show that free chlorine, monochloramine, ozone and chlorine dioxide followed by flushing can reduce adhered spores by > 3.0 log 10 on cement-mortar. Published by Elsevier Ltd.

  19. Defects in Hardwood Veneer Logs: Their Frequency and Importance

    Treesearch

    E.S. Harrar

    1954-01-01

    Most southern hardwood veneer and plywood plants have some method of classifying logs by grade to control the purchase price paid for logs bought on the open market. Such log-grading systems have been developed by experience and are dependent to a large extent upon the ability of the grader and his knowledge of veneer grades and yields required for the specific product...

  20. Calibration of the Concorde radiation detection instrument and measurements at SST altitude.

    DOT National Transportation Integrated Search

    1971-06-01

    Performance tests were carried out on a solar cosmic radiation detection instrument developed for the Concorde SST. The instrument calibration curve (log dose-rate vs instrument reading) was reasonably linear from 0.004 to 1 rem/hr for both gamma rad...

  1. Increasing the Operational Value of Event Messages

    NASA Technical Reports Server (NTRS)

    Li, Zhenping; Savkli, Cetin; Smith, Dan

    2003-01-01

    Assessing the health of a space mission has traditionally been performed using telemetry analysis tools. Parameter values are compared to known operational limits and are plotted over various time periods. This presentation begins with the notion that there is an incredible amount of untapped information contained within the mission s event message logs. Through creative advancements in message handling tools, the event message logs can be used to better assess spacecraft and ground system status and to highlight and report on conditions not readily apparent when messages are evaluated one-at-a-time during a real-time pass. Work in this area is being funded as part of a larger NASA effort at the Goddard Space Flight Center to create component-based, middleware-based, standards-based general purpose ground system architecture referred to as GMSEC - the GSFC Mission Services Evolution Center. The new capabilities and operational concepts for event display, event data analyses and data mining are being developed by Lockheed Martin and the new subsystem has been named GREAT - the GMSEC Reusable Event Analysis Toolkit. Planned for use on existing and future missions, GREAT has the potential to increase operational efficiency in areas of problem detection and analysis, general status reporting, and real-time situational awareness.

  2. DUMAND-II (deep underwater muon and neutrino detector) progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, K.K.; The DUMAND Collaboration

    1995-07-10

    The DUMAND II detector will search for astronomical sources of high energy neutrinos. Successful deployment of the basic infrastructure, including the shore cable, the underwater junction box, and an environmental module was accomplished in December, 1993. One optical module string was also deployed and operated, logging data for about 10 hours. The underwater cable was connected to the shore station where we were able to successfully exercise system controls and log further environmental data. After this time, water leaking into the electronics control module for the deployed string disabled the string electrical system. The acquired data are consistent with themore » expected rate of downgoing muons, and our ability to reconstruct muons was demonstrated. The measured acoustical backgrounds are consistent with expectation, which should allow acoustical detection of nearby PeV particle cascades. The disabled string has been recovered and is undergoing repairs ashore. We have identified the source of the water leak and implemented additional testing and QC procedures to ensure no repetition in our next deployment. We will be ready to deploy three strings and begin continuous data taking in late 1994 or early 1995. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.« less

  3. Compact Modules for Wireless Communication Systems in the E-Band (71-76 GHz)

    NASA Astrophysics Data System (ADS)

    Montero-de-Paz, Javier; Oprea, Ion; Rymanov, Vitaly; Babiel, Sebastian; García-Muñoz, Luis Enrique; Lisauskas, Alvydas; Hoefle, Matthias; Jimenez, Álvaro; Cojocari, Oleg; Segovia-Vargas, Daniel; Palandöken, Merih; Tekin, Tolga; Stöhr, Andreas; Carpintero, Guillermo

    2013-04-01

    The millimeter-wave spectrum above 70 GHz provides a cost-effective solution to increase the wireless communications data rates by increasing the carrier wave frequencies. We report on the development of two key components of a wireless transmission system, a high-speed photodiode (HS-PD) and a Schottky Barrier Diode (SBD). Both components operate uncooled, a key issue in the development of compact modules. On the transmitter side, an improved design of the HS-PD allows it to deliver an output RF power exceeding 0 dBm (1 mW). On the receiver side, we present the design process and achieved results on the development of a compact direct envelope detection receiver based on a quasi-optical SDB module. Different resonant (meander dipole) and broadband (Log-Spiral and Log-Periodic) planar antenna solutions are designed, matching the antenna and Schottky diode impedances at high frequency. Impedance matching at baseband is also provided by means of an impedance transition to a 50 Ohm output. From this comparison, we demonstrate the excellent performance of the broadband antennas over the entire E-band by setting up a short-range wireless link transmitting a 1 Gbps data signal.

  4. Analysis of alcohol-based hand sanitizer delivery systems: efficacy of foam, gel, and wipes against influenza A (H1N1) virus on hands.

    PubMed

    Larson, Elaine L; Cohen, Bevin; Baxter, Kathleen A

    2012-11-01

    Minimal research has been published evaluating the effectiveness of hand hygiene delivery systems (ie, rubs, foams, or wipes) at removing viruses from hands. The purposes of this study were to determine the effect of several alcohol-based hand sanitizers in removing influenza A (H1N1) virus, and to compare the effectiveness of foam, gel, and hand wipe products. Hands of 30 volunteers were inoculated with H1N1 and randomized to treatment with foam, gel, or hand wipe applied to half of each volunteer's finger pads. The log(10) count of each subject's treated and untreated finger pads were averaged. Log(10) reductions were calculated from these differences and averaged within treatment group. Between-treatment analysis compared changes from the untreated finger pads using analysis of covariance with treatment as a factor and the average log(10) untreated finger pads as the covariate. Log(10) counts on control finger pads were 2.7-5.3 log(10) of the 50% infectious dose for tissue culture (TCID(50)/0.1 mL) (mean, 3.8 ± 0.5 log(10) TCID(50)/0.1 mL), and treated finger pad counts for all test products were 0.5-1.9 log(10) TCID(50)/0.1 mL (mean, 0.53 ± 0.17 log(10) TCID(50)/0.1 mL). Treatments with all products resulted in a significant reduction in viral titers (>3 logs) at their respective exposure times that were statistically comparable. All 3 delivery systems (foam, gel, and wipe) produced significantly reduced viral counts on hands. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  5. Fuzzy inference system for identification of geological stratigraphy off Prydz Bay, East Antarctica

    NASA Astrophysics Data System (ADS)

    Singh, Upendra K.

    2011-12-01

    The analysis of well logging data plays key role in the exploration and development of hydrocarbon reservoirs. Various well log parameters such as porosity, gamma ray, density, transit time and resistivity, help in classification of strata and estimation of the physical, electrical and acoustical properties of the subsurface lithology. Strong and conspicuous changes in some of the log parameters associated with any particular geological stratigraphy formation are function of its composition, physical properties that help in classification. However some substrata show moderate values in respective log parameters and make difficult to identify the kind of strata, if we go by the standard variability ranges of any log parameters and visual inspection. The complexity increases further with more number of sensors involved. An attempt is made to identify the kinds of stratigraphy from well logs over Prydz bay basin, East Antarctica using fuzzy inference system. A model is built based on few data sets of known stratigraphy and further the network model is used as test model to infer the lithology of a borehole from their geophysical logs, not used in simulation. Initially the fuzzy based algorithm is trained, validated and tested on well log data and finally identifies the formation lithology of a hydrocarbon reservoir system of study area. The effectiveness of this technique is demonstrated by the analysis of the results for actual lithologs and coring data of ODP Leg 188. The fuzzy results show that the training performance equals to 82.95% while the prediction ability is 87.69%. The fuzzy results are very encouraging and the model is able to decipher even thin layer seams and other strata from geophysical logs. The result provides the significant sand formation of depth range 316.0- 341.0 m, where core recovery is incomplete.

  6. An invariability-area relationship sheds new light on the spatial scaling of ecological stability.

    PubMed

    Wang, Shaopeng; Loreau, Michel; Arnoldi, Jean-Francois; Fang, Jingyun; Rahman, K Abd; Tao, Shengli; de Mazancourt, Claire

    2017-05-19

    The spatial scaling of stability is key to understanding ecological sustainability across scales and the sensitivity of ecosystems to habitat destruction. Here we propose the invariability-area relationship (IAR) as a novel approach to investigate the spatial scaling of stability. The shape and slope of IAR are largely determined by patterns of spatial synchrony across scales. When synchrony decays exponentially with distance, IARs exhibit three phases, characterized by steeper increases in invariability at both small and large scales. Such triphasic IARs are observed for primary productivity from plot to continental scales. When synchrony decays as a power law with distance, IARs are quasilinear on a log-log scale. Such quasilinear IARs are observed for North American bird biomass at both species and community levels. The IAR provides a quantitative tool to predict the effects of habitat loss on population and ecosystem stability and to detect regime shifts in spatial ecological systems, which are goals of relevance to conservation and policy.

  7. Windows Instant Messaging App Forensics: Facebook and Skype as Case Studies

    PubMed Central

    Yang, Teing Yee; Dehghantanha, Ali; Choo, Kim-Kwang Raymond; Muda, Zaiton

    2016-01-01

    Instant messaging (IM) has changed the way people communicate with each other. However, the interactive and instant nature of these applications (apps) made them an attractive choice for malicious cyber activities such as phishing. The forensic examination of IM apps for modern Windows 8.1 (or later) has been largely unexplored, as the platform is relatively new. In this paper, we seek to determine the data remnants from the use of two popular Windows Store application software for instant messaging, namely Facebook and Skype on a Windows 8.1 client machine. This research contributes to an in-depth understanding of the types of terrestrial artefacts that are likely to remain after the use of instant messaging services and application software on a contemporary Windows operating system. Potential artefacts detected during the research include data relating to the installation or uninstallation of the instant messaging application software, log-in and log-off information, contact lists, conversations, and transferred files. PMID:26982207

  8. Windows Instant Messaging App Forensics: Facebook and Skype as Case Studies.

    PubMed

    Yang, Teing Yee; Dehghantanha, Ali; Choo, Kim-Kwang Raymond; Muda, Zaiton

    2016-01-01

    Instant messaging (IM) has changed the way people communicate with each other. However, the interactive and instant nature of these applications (apps) made them an attractive choice for malicious cyber activities such as phishing. The forensic examination of IM apps for modern Windows 8.1 (or later) has been largely unexplored, as the platform is relatively new. In this paper, we seek to determine the data remnants from the use of two popular Windows Store application software for instant messaging, namely Facebook and Skype on a Windows 8.1 client machine. This research contributes to an in-depth understanding of the types of terrestrial artefacts that are likely to remain after the use of instant messaging services and application software on a contemporary Windows operating system. Potential artefacts detected during the research include data relating to the installation or uninstallation of the instant messaging application software, log-in and log-off information, contact lists, conversations, and transferred files.

  9. Meta-Analysis of the Reduction of Norovirus and Male-Specific Coliphage Concentrations in Wastewater Treatment Plants.

    PubMed

    Pouillot, Régis; Van Doren, Jane M; Woods, Jacquelina; Plante, Daniel; Smith, Mark; Goblick, Gregory; Roberts, Christopher; Locas, Annie; Hajen, Walter; Stobo, Jeffrey; White, John; Holtzman, Jennifer; Buenaventura, Enrico; Burkhardt, William; Catford, Angela; Edwards, Robyn; DePaola, Angelo; Calci, Kevin R

    2015-07-01

    Human norovirus (NoV) is the leading cause of foodborne illness in the United States and Canada. Wastewater treatment plant (WWTP) effluents impacting bivalve mollusk-growing areas are potential sources of NoV contamination. We have developed a meta-analysis that evaluates WWTP influent concentrations and log10 reductions of NoV genotype I (NoV GI; in numbers of genome copies per liter [gc/liter]), NoV genotype II (NoV GII; in gc/liter), and male-specific coliphage (MSC; in number of PFU per liter), a proposed viral surrogate for NoV. The meta-analysis included relevant data (2,943 measurements) reported in the scientific literature through September 2013 and previously unpublished surveillance data from the United States and Canada. Model results indicated that the mean WWTP influent concentration of NoV GII (3.9 log10 gc/liter; 95% credible interval [CI], 3.5, 4.3 log10 gc/liter) is larger than the value for NoV GI (1.5 log10 gc/liter; 95% CI, 0.4, 2.4 log10 gc/liter), with large variations occurring from one WWTP to another. For WWTPs with mechanical systems and chlorine disinfection, mean log10 reductions were -2.4 log10 gc/liter (95% CI, -3.9, -1.1 log10 gc/liter) for NoV GI, -2.7 log10 gc/liter (95% CI, -3.6, -1.9 log10 gc/liter) for NoV GII, and -2.9 log10 PFU per liter (95% CI, -3.4, -2.4 log10 PFU per liter) for MSCs. Comparable values for WWTPs with lagoon systems and chlorine disinfection were -1.4 log10 gc/liter (95% CI, -3.3, 0.5 log10 gc/liter) for NoV GI, -1.7 log10 gc/liter (95% CI, -3.1, -0.3 log10 gc/liter) for NoV GII, and -3.6 log10 PFU per liter (95% CI, -4.8, -2.4 PFU per liter) for MSCs. Within WWTPs, correlations exist between mean NoV GI and NoV GII influent concentrations and between the mean log10 reduction in NoV GII and the mean log10 reduction in MSCs. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  10. Do you see what I hear: experiments in multi-channel sound and 3D visualization for network monitoring?

    NASA Astrophysics Data System (ADS)

    Ballora, Mark; Hall, David L.

    2010-04-01

    Detection of intrusions is a continuing problem in network security. Due to the large volumes of data recorded in Web server logs, analysis is typically forensic, taking place only after a problem has occurred. This paper describes a novel method of representing Web log information through multi-channel sound, while simultaneously visualizing network activity using a 3-D immersive environment. We are exploring the detection of intrusion signatures and patterns, utilizing human aural and visual pattern recognition ability to detect intrusions as they occur. IP addresses and return codes are mapped to an informative and unobtrusive listening environment to act as a situational sound track of Web traffic. Web log data is parsed and formatted using Python, then read as a data array by the synthesis language SuperCollider [1], which renders it as a sonification. This can be done either for the study of pre-existing data sets or in monitoring Web traffic in real time. Components rendered aurally include IP address, geographical information, and server Return Codes. Users can interact with the data, speeding or slowing the speed of representation (for pre-existing data sets) or "mixing" sound components to optimize intelligibility for tracking suspicious activity.

  11. Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA

    PubMed Central

    Jahan, Munira; Lutful Moben, Ahmed; Tabassum, Shahina

    2014-01-01

    ABSTRACT Background Both real-time-polymerase chain reaction (PCR) and hybrid capture 2 (HC2) assay can detect and quantify hepatitis B virus (HBV) DNA. However, real-time-PCR can detect a wide range of HBV DNA, while HC2 assay could not detect lower levels of viremia. The present study was designed to detect and quantify HBV DNA by real-time-PCR and HC2 assay and compare the quantitative data of these two assays. Materials and methods A cross-sectional study was conducted in between July 2010 and June 2011. A total of 66 serologically diagnosed chronic hepatitis B (CHB) patients were selected for the study. Real-time-PCR and HC2 assay was done to detect HBV DNA. Data were analyzed by statistical Package for the social sciences (SPSS). Results Among 66 serologically diagnosed chronic hepatitis B patients 40 (60.61%) patients had detectable and 26 (39.39%) had undetectable HBV DNA by HC2 assay. Concordant results were obtained for 40 (60.61%) out of these 66 patients by real-time-PCR and HC2 assay with mean viral load of 7.06 ± 1.13 log10 copies/ml and 6.95 ± 1.08 log10 copies/ml, respectively. In the remaining 26 patients, HBV DNA was detectable by real-time-PCR in 20 patients (mean HBV DNA level was 3.67 ± 0.72 log10 copies/ml. However, HBV DNA could not be detectable in six cases by the both assays. The study showed strong correlation (r = 0.915) between real-time-PCR and HC2 assay for the detection and quantification of HBV DNA. Conclusion HC2 assay may be used as an alternative to real-time-PCR for CHB patients. How to cite this article: Majid F, Jahan M, Moben AL, Tabassum S. Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA. Euroasian J Hepato-Gastroenterol 2014;4(1):31-35. PMID:29264316

  12. Microbial diversity and prevalence of foodborne pathogens in cheap and junk foods consumed by primary schoolchildren.

    PubMed

    Kim, M J; Kim, S A; Kang, Y S; Hwang, I G; Rhee, M S

    2013-07-01

    Aerobic plate counts (APC), coliforms, Bacillus cereus, Escherichia coli and eight foodborne pathogens were tested in 1008 cheap and junk foods, including candies, dried cakes, chewing gum, chocolate, dried and seasoned seafood, ice cream, and sugary foods. APCs were positive for 342 samples (33·9%), and the majority of the counts were 2-3 log CFU g(-1) or ml(-1) (average: 1·10 log CFU g(-1) or ml(-1) ). Most samples (97·3%) contained no coliforms (average: 0·07 log CFU g(-1) or ml(-1) ). Bacillus cereus was detected in 68 samples (average: 0·14 log CFU g(-1) or ml(-1) ). Escherichia coli and Listeria monocytogenes were detected in 6 and 1 samples, respectively, whereas other foodborne pathogens were not isolated. The highest bacterial counts were associated with dried and seasoned seafood products and dried cakes, suggesting that appropriate regulations of these food types should be considered. Cheap and junk foods were produced mainly in developing countries, but there were no significant differences in the bacterial counts among different countries of origin. The presence of foodborne pathogens may pose a risk for children. These results suggest that there is cause for deeper concern about the safety of these foods and that effective countermeasures should be established to improve their microbiological safety. Food safety is especially important for children, but only limited information is available about the microbiological quality of cheap and junk foods that are consumed frequently by primary schoolchildren (e.g. dried cakes, candies and chocolates). The present study investigated the microbial quality of cheap and junk foods, and our results indicate that these foods are a potential health risk for children, therefore, deeper concern about the safety of these foods and effective countermeasures should be established to improve their microbiological safety. The present study may contribute to the development of an appropriate child food safety management system. © 2013 The Society for Applied Microbiology.

  13. Comparative Recovery of Two Human Norovirus Surrogates, Feline Calicivirus and Murine Norovirus, with a Wet Vacuum System, Macrofoam-Tipped Swab, and Bottle Extraction Method from Carpets.

    PubMed

    Buckley, David; Fraser, Angela; Pettigrew, Charles; Anderson, Jeffery; Jiang, Xiuping

    2018-05-10

    Human noroviruses (HuNoV) are the leading cause of known foodborne illness in the United States, but direct detection during outbreak investigations is challenging. On the other hand, sampling both hard and soft environmental surfaces can be used to improve outbreak investigations. Currently, we lack virus recovery methods for soft surfaces, such as carpet, despite evidence suggesting that carpets contribute to HuNoV outbreaks. Our aim was to compare two recovery methods, wet vacuum and swabbing, for routine carpet sampling of HuNoV against a laboratory reference method known as bottle extraction (BE). Specifically, we compared the microbial vacuum (MVAC), macrofoam-tipped swab (MS), and BE by using HuNoV surrogates, feline calicivirus (FCV) and murine norovirus (MNV), inoculated on wool and nylon carpet carriers. The highest recovery of infectious FCV from wool was 5.51, 3.76, and 5.16 log PFU, whereas on nylon, recovery was 5.03, 3.62, and 4.75 log PFU by using BE, MS, and MVAC, respectively. On the other hand, the highest recovery of infectious MNV from wool was 6.10, 4.50, and 5.99 log PFU, while recovery on nylon was 6.07, 4.58, and 6.13 log PFU by using BE, MS, and MVAC, respectively. Significantly more PFU and genomic copies were recovered by using BE and MVAC compared with MS, while buffer type played a significant role in recovery of infectious FCV.

  14. Figure-ground segregation by motion contrast and by luminance contrast.

    PubMed

    Regan, D; Beverley, K I

    1984-05-01

    Some naturally camouflaged objects are invisible unless they move; their boundaries are then defined by motion contrast between object and background. We compared the visual detection of such camouflaged objects with the detection of objects whose boundaries were defined by luminance contrast. The summation field area is 0.16 deg2 , and the summation time constant is 750 msec for parafoveally viewed objects whose boundaries are defined by motion contrast; these values are, respectively, about 5 and 12 times larger than the corresponding values for objects defined by luminance contrast. The log detection threshold is proportional to the eccentricity for a camouflaged object of constant area. The effect of eccentricity on threshold is less for large objects than for small objects. The log summation field diameter for detecting camouflaged objects is roughly proportional to the eccentricity, increasing to about 20 deg at 32-deg eccentricity. In contrast to the 100:1 increase of summation area for detecting camouflaged objects, the temporal summation time constant changes by only 40% between eccentricities of 0 and 16 deg.

  15. Creative Analytics of Mission Ops Event Messages

    NASA Technical Reports Server (NTRS)

    Smith, Dan

    2017-01-01

    Historically, tremendous effort has been put into processing and displaying mission health and safety telemetry data; and relatively little attention has been paid to extracting information from missions time-tagged event log messages. Todays missions may log tens of thousands of messages per day and the numbers are expected to dramatically increase as satellite fleets and constellations are launched, as security monitoring continues to evolve, and as the overall complexity of ground system operations increases. The logs may contain information about orbital events, scheduled and actual observations, device status and anomalies, when operators were logged on, when commands were resent, when there were data drop outs or system failures, and much much more. When dealing with distributed space missions or operational fleets, it becomes even more important to systematically analyze this data. Several advanced information systems technologies make it appropriate to now develop analytic capabilities which can increase mission situational awareness, reduce mission risk, enable better event-driven automation and cross-mission collaborations, and lead to improved operations strategies: Industry Standard for Log Messages. The Object Management Group (OMG) Space Domain Task Force (SDTF) standards organization is in the process of creating a formal standard for industry for event log messages. The format is based on work at NASA GSFC. Open System Architectures. The DoD, NASA, and others are moving towards common open system architectures for mission ground data systems based on work at NASA GSFC with the full support of the commercial product industry and major integration contractors. Text Analytics. A specific area of data analytics which applies statistical, linguistic, and structural techniques to extract and classify information from textual sources. This presentation describes work now underway at NASA to increase situational awareness through the collection of non-telemetry mission operations information into a common log format and then providing display and analytics tools to provide in-depth assessment of the log contents. The work includes: Common interface formats for acquiring time-tagged text messages Conversion of common files for schedules, orbital events, and stored commands to the common log format Innovative displays to depict thousands of messages on a single display Structured English text queries against the log message data store, extensible to a more mature natural language query capability Goal of speech-to-text and text-to-speech additions to create a personal mission operations assistant to aid on-console operations. A wide variety of planned uses identified by the mission operations teams will be discussed.

  16. The Fundamental Stellar Parameters of FGK Stars in the SEEDS Survey

    NASA Astrophysics Data System (ADS)

    Rich, Evan; Wisniewski, John P.; SEEDS Team

    2017-01-01

    Large exoplanet surveys have successfully detected thousands of exoplanets to-date. Utilizing these detections and non-detections to constrain our understanding of the formation and evolution of planetary systems also requires a detailed understanding of the basic properties of their host stars. We have determined the basic stellar properties of F, K, and G stars in the Strategic Exploration of Exoplanets and Disks with Subaru (SEEDS) survey from echelle spectra taken at the Apache Point Observatory's 3.5m telescope. Using ROBOSPECT to extract line fluxes and TGVIT to calculate the fundamental parameters, we have computed Teff, log(g), vt, [Fe/H], chromospheric activity, lithium abundance, and the age for our sample. Our methodology was calibrated against previously published results for a portion of our sample. The future meta-analysis of the results of the SEEDS survey will utilize our results to constrain the occurrence of detected co-moving companions with the properties of their host stars.

  17. Validation of an Electronic System for Recording Medical Student Patient Encounters

    PubMed Central

    Nkoy, Flory L.; Petersen, Sarah; Matheny Antommaria, Armand H.; Maloney, Christopher G.

    2008-01-01

    The Liaison Committee for Medical Education requires monitoring of the students’ clinical experiences. Student logs, typically used for this purpose, have a number of limitations. We used an electronic system called Patient Tracker to passively generate student encounter data. The data contained in Patient Tracker was compared to the information reported on student logs and data abstracted from the patients’ charts. Patient Tracker identified 30% more encounters than the student logs. Compared to the student logs, Patient Tracker contained a higher average number of diagnoses per encounter (2.28 vs. 1.03, p<0.01). The diagnostic data contained in Patient Tracker was also more accurate under 4 different definitions of accuracy. Only 1.3% (9/677) of diagnoses in Patient Tracker vs. 16.9% (102/601) diagnoses in the logs could not be validated in patients’ charts (p<0.01). Patient Tracker is a more effective and accurate tool for documenting student clinical encounters than the conventional student logs. PMID:18999155

  18. Classification of epileptic seizures using wavelet packet log energy and norm entropies with recurrent Elman neural network classifier.

    PubMed

    Raghu, S; Sriraam, N; Kumar, G Pradeep

    2017-02-01

    Electroencephalogram shortly termed as EEG is considered as the fundamental segment for the assessment of the neural activities in the brain. In cognitive neuroscience domain, EEG-based assessment method is found to be superior due to its non-invasive ability to detect deep brain structure while exhibiting superior spatial resolutions. Especially for studying the neurodynamic behavior of epileptic seizures, EEG recordings reflect the neuronal activity of the brain and thus provide required clinical diagnostic information for the neurologist. This specific proposed study makes use of wavelet packet based log and norm entropies with a recurrent Elman neural network (REN) for the automated detection of epileptic seizures. Three conditions, normal, pre-ictal and epileptic EEG recordings were considered for the proposed study. An adaptive Weiner filter was initially applied to remove the power line noise of 50 Hz from raw EEG recordings. Raw EEGs were segmented into 1 s patterns to ensure stationarity of the signal. Then wavelet packet using Haar wavelet with a five level decomposition was introduced and two entropies, log and norm were estimated and were applied to REN classifier to perform binary classification. The non-linear Wilcoxon statistical test was applied to observe the variation in the features under these conditions. The effect of log energy entropy (without wavelets) was also studied. It was found from the simulation results that the wavelet packet log entropy with REN classifier yielded a classification accuracy of 99.70 % for normal-pre-ictal, 99.70 % for normal-epileptic and 99.85 % for pre-ictal-epileptic.

  19. Constraining the H2 column density distribution at z˜3 from composite DLA spectra

    NASA Astrophysics Data System (ADS)

    Balashev, S. A.; Noterdaeme, P.

    2018-04-01

    We present the detection of the average H2 absorption signal in the overall population of neutral gas absorption systems at z ˜ 3 using composite absorption spectra built from the Sloan Digital Sky Survey-III damped Lyman-α catalogue. We present a new technique to directly measure the H2 column density distribution function f_H_2(N) from the average H2 absorption signal. Assuming a power-law column density distribution, we obtain a slope β = -1.29 ± 0.06(stat) ± 0.10 (sys) and an incidence rate of strong H2 absorptions (with N(H2) ≳ 1018 cm-2) to be 4.0 ± 0.5(stat) ± 1.0 (sys) % in H I absorption systems with N(H I)≥1020 cm-2. Assuming the same inflexion point where f_H_2(N) steepens as at z = 0, we estimate that the cosmological density of H2 in the column density range log N(H_2) (cm^{-2})= 18-22 is ˜15% of the total. We find one order of magnitude higher H2 incident rate in a sub-sample of extremely strong DLAs (log N(H I) (cm^{-2}) ≥ 21.7), which, together with the the derived shape of f_H_2(N), suggests that the typical H I-H2 transition column density in DLAs is log N(H)(cm-2) ≳ 22.3 in agreement with theoretical expectations for the average (low) metallicity of DLAs at high-z.

  20. Comparative evaluation of a laboratory developed real-time PCR assay and the RealStar® HHV-6 PCR Kit for quantitative detection of human herpesvirus 6.

    PubMed

    Yip, Cyril C Y; Sridhar, Siddharth; Cheng, Andrew K W; Fung, Ami M Y; Cheng, Vincent C C; Chan, Kwok-Hung; Yuen, Kwok-Yung

    2017-08-01

    HHV-6 reactivation in immunocompromised patients is common and may be associated with serious morbidity and mortality; therefore, early detection and initiation of therapy might be of benefit. Real-time PCR assays allow for early identification of HHV-6 reactivation to assist in providing a timely response. Thus, we compared the performance of an in-house developed HHV-6 quantitative PCR assay with a commercially available kit, the RealStar ® HHV-6 PCR Kit. The analytical sensitivity, analytical specificity, linearity, precision and accuracy of the in-house developed HHV-6 qPCR assay were evaluated. The diagnostic performance of the in-house HHV-6 qPCR assay was compared with the RealStar ® HHV-6 PCR Kit, using 72 clinical specimens and 17 proficiency testing samples. Linear regression analysis of the quantitative results showed a dynamic range from 2 to 10 log 10 copies/ml and a coefficient of determination (R 2 ) of 0.999 for the in-house assay. A dilution series demonstrated a limit of detection and a limit of quantification of 1.7 log 10 and 2 log 10 copies/ml, respectively. The precision of the assay was highly reproducible among runs with coefficients of variance (CV) ranging from 0.27% to 4.37%. A comparison of 27 matched samples showed an excellent correlation between the quantitative viral loads measured by the in-house HHV-6 qPCR assay and the RealStar ® HHV-6 PCR Kit (R 2 =0.926; P<0.0001), with an average bias of -0.24 log 10 copies/ml. The in-house developed HHV-6 qPCR method is a sensitive and reliable assay with lower cost for the detection and quantification of HHV-6 DNA when compared to the RealStar ® HHV-6 PCR Kit. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Geological and geophysical analysis of Coso Geothermal Exploration Hole No. 1 (CGEH-1), Coso Hot Springs KGRA, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galbraith, R.M.

    1978-05-01

    The Coso Geothermal Exploration Hole number one (CGEH-1) was drilled in the Coso Hot Springs KGRA, California, from September 2 to December 2, 1977. Chip samples were collected at ten foot intervals and extensive geophysical logging surveys were conducted to document the geologic character of the geothermal system as penetrated by CGEH-1. The major rock units encountered include a mafic metamorphic sequence and a leucogranite which intruded the metamorphic rocks. Only weak hydrothermal alteration was noted in these rocks. Drillhole surveys and drilling rate data indicate that the geothermal system is structurally controlled and that the drillhole itself was stronglymore » influenced by structural zones. Water chemistry indicates that this geothermal resource is a hot-water rather than a vapor-dominated system. Several geophysical logs were employed to characcterize the drillhole geology. The natural gamma and neutron porosity logs indicate gross rock type and the accoustic logs indicate fractured rock and potentially permeable zones. A series of temperature logs run as a function of time during and after the completion of drilling were most useful in delineating the zones of maximum heat flux. Convective heat flow and temperatures greater than 350/sup 0/F appear to occur only along an open fracture system encountered between depths of 1850 and 2775 feet. Temperature logs indicate a negative thermal gradient below 3000 feet.« less

  2. Geological and geophysical analysis of Coso Geothermal Exploration Hole No. 1 (CGEH-1), Coso Hot Springs KGRA, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galbraith, R.M.

    1978-05-01

    The Coso Geothermal Exploration Hole number one (CGEH-1) was drilled in the Coso Hot Springs KGRA, California from September 2 to December 2, 1977. Chip samples were collected at ten foot intervals and extensive geophysical logging surveys were conducted to document the geologic character of the geothermal system as penetrated by CGEH-1. The major rock units encountered include a mafic metamorphic sequence and a leucogranite which intruded the metamorphic rocks. Only weak hydrothermal alteration was noted in these rocks. Drillhole surveys and drilling rate data indicate that the geothermal system is structurally controlled and that the drillhole itself was stronglymore » influenced by structural zones. Water chemistry indicates that this geothermal resource is a hot-water rather than a vapor-dominated system. Several geophysical logs were employed to characterize the drillhole geology. The natural gamma and neutron porosity logs indicate gross rock type and the acoustic logs indicate fractured rock and potentially permeable zones. A series of temperature logs run as a function of time during and after the completion of drilling were most useful in delineating the zones of maximum heat flux. Convective heat flow and temperatures greater than 350/sup 0/F appear to occur only along an open fracture system encountered between depths of 1850 and 2775 feet. Temperature logs indicate a negative thermal gradient below 3000 feet.« less

  3. Influenza detection and prediction algorithms: comparative accuracy trial in Östergötland county, Sweden, 2008-2012.

    PubMed

    Spreco, A; Eriksson, O; Dahlström, Ö; Timpka, T

    2017-07-01

    Methods for the detection of influenza epidemics and prediction of their progress have seldom been comparatively evaluated using prospective designs. This study aimed to perform a prospective comparative trial of algorithms for the detection and prediction of increased local influenza activity. Data on clinical influenza diagnoses recorded by physicians and syndromic data from a telenursing service were used. Five detection and three prediction algorithms previously evaluated in public health settings were calibrated and then evaluated over 3 years. When applied on diagnostic data, only detection using the Serfling regression method and prediction using the non-adaptive log-linear regression method showed acceptable performances during winter influenza seasons. For the syndromic data, none of the detection algorithms displayed a satisfactory performance, while non-adaptive log-linear regression was the best performing prediction method. We conclude that evidence was found for that available algorithms for influenza detection and prediction display satisfactory performance when applied on local diagnostic data during winter influenza seasons. When applied on local syndromic data, the evaluated algorithms did not display consistent performance. Further evaluations and research on combination of methods of these types in public health information infrastructures for 'nowcasting' (integrated detection and prediction) of influenza activity are warranted.

  4. UNIX security in a supercomputing environment

    NASA Technical Reports Server (NTRS)

    Bishop, Matt

    1989-01-01

    The author critiques some security mechanisms in most versions of the Unix operating system and suggests more effective tools that either have working prototypes or have been implemented, for example in secure Unix systems. Although no computer (not even a secure one) is impenetrable, breaking into systems with these alternate mechanisms will cost more, require more skill, and be more easily detected than penetrations of systems without these mechanisms. The mechanisms described fall into four classes (with considerable overlap). User authentication at the local host affirms the identity of the person using the computer. The principle of least privilege dictates that properly authenticated users should have rights precisely sufficient to perform their tasks, and system administration functions should be compartmentalized; to this end, access control lists or capabilities should either replace or augment the default Unix protection system, and mandatory access controls implementing multilevel security models and integrity mechanisms should be available. Since most users access supercomputing environments using networks, the third class of mechanisms augments authentication (where feasible). As no security is perfect, the fourth class of mechanism logs events that may indicate possible security violations; this will allow the reconstruction of a successful penetration (if discovered), or possibly the detection of an attempted penetration.

  5. Evidence acquisition tools for cyber sex crimes investigations

    NASA Astrophysics Data System (ADS)

    Novotny, Jon M.; Meehan, A.; Schulte, D.; Manes, Gavin W.; Shenoi, Sujeet

    2002-08-01

    Sexually explicit Internet chat rooms are increasingly used by pedophiles to reach potential victims. Logging and linking suspects to chat room conversations and e-mails exchanged with undercover detectives are crucial to prosecuting travelers, i.e., pedophiles who travel across state lines to engage in sexual acts with minors. This paper describes two tools, a chat room monitor and a remote fingerprinter, for acquiring and preserving evidence. The chat room monitor logs online communications as well as screen images and keystrokes of the undercover detective. stored to allow the chronological reconstruction and replay of the investigation. The remote fingerprinter uses sophisticated scanning techniques to capture and preserve a unique fingerprint of the suspect's computer over the Internet. Once the suspect's computer is seized, it is scanned again; matching this new fingerprint with the remotely acquired fingerprint establishes that the suspect's computer was used to communicate with the detective.

  6. Influence of inoculation levels and processing parameters on the survival of Campylobacter jejuni in German style fermented turkey sausages.

    PubMed

    Alter, Thomas; Bori, Anouchka; Hamedi, Ahmad; Ellerbroek, Lüppo; Fehlhaber, Karsten

    2006-10-01

    This study investigated the influence of inoculum levels and manufacturing methods on the survival of Campylobacter (C.) jejuni in raw fermented turkey sausages. Sausages were prepared and inoculated with C. jejuni. After inoculation, these sausages were processed and ripened for 8 days. Samples were taken throughout the ripening process. The presence of C. jejuni was established bacteriologically. Additionally, lactic acid bacteria were enumerated, pH values and water activity were measured to verify the ripening process. To detect changes in genotype and verify the identity of the recovered clones, AFLP analysis was carried out on the re-isolated strains. Whereas no C. jejuni were detectable when inoculating the sausages with the lowest inoculum (0.08-0.44 log(10) cfu/g sausage emulsion), C. jejuni were detectable for 12-24h by enrichment when inoculated with approximately 2 log(10) cfu/g. After inoculation with 4 and 6 log(10) cfu/g respectively, C. jejuni were detectable without enrichment for 12-48 h and by enrichment for 144 h at the most. The greatest decrease of the C. jejuni population occurred during the first 4 h of ripening. Only a very high inoculum level allowed the survival of the organism during a fermentation process and during ripening to pose a potential risk for consumers. Lower initial Campylobacter inoculums will be eliminated during proper ripening of the sausages, if sufficient decrease in water activity and pH-value is ensured.

  7. Performance Characteristics and Comparison of Abbott and artus Real-Time Systems for Hepatitis B Virus DNA Quantification ▿

    PubMed Central

    Ismail, Ashrafali M.; Sivakumar, Jayashree; Anantharam, Raghavendran; Dayalan, Sujitha; Samuel, Prasanna; Fletcher, Gnanadurai J.; Gnanamony, Manu; Abraham, Priya

    2011-01-01

    Virological monitoring of hepatitis B virus (HBV) DNA is critical to the management of HBV infection. With several HBV DNA quantification assays available, it is important to use the most efficient testing system for virological monitoring. In this study, we evaluated the performance characteristics and comparability of three HBV DNA quantification systems: Abbott HBV real-time PCR (Abbott PCR), artus HBV real-time PCR with QIAamp DNA blood kit purification (artus-DB), and artus HBV real-time PCR with the QIAamp DSP virus kit purification (artus-DSP). The lower limits of detection of these systems were established against the WHO international standards for HBV DNA and were found to be 1.43, 82, and 9 IU/ml, respectively. The intra-assay and interassay coefficients of variation of plasma samples (1 to 6 log10 IU/ml) ranged between 0.05 to 8.34% and 0.16 to 3.48% for the Abbott PCR, 1.53 to 26.85% and 0.50 to 12.89% for artus-DB, and 0.29 to 7.42% and 0.94 to 3.01% for artus-DSP, respectively. Ninety HBV clinical samples were used for comparison of assays, and paired quantitative results showed strong correlation by linear regression analysis (artus-DB with Abbott PCR, r = 0.95; Abbott PCR with artus-DSP, r = 0.97; and artus-DSP with artus-DB, r = 0.94). Bland-Altman analysis showed a good level of agreement for Abbott PCR and artus-DSP, with a mean difference of 0.10 log10 IU/ml and limits of agreement of −0.91 to 1.11 log10 IU/ml. No genotype-specific bias was seen in all three systems for HBV genotypes A, C, and D, which are predominant in this region. This finding illustrates that the Abbott real-time HBV and artus-DSP systems show more comparable performance than the artus-DB system, meeting the current guidelines for assays to be used in the management of hepatitis B. PMID:21795507

  8. Performance characteristics and comparison of Abbott and artus real-time systems for hepatitis B virus DNA quantification.

    PubMed

    Ismail, Ashrafali M; Sivakumar, Jayashree; Anantharam, Raghavendran; Dayalan, Sujitha; Samuel, Prasanna; Fletcher, Gnanadurai J; Gnanamony, Manu; Abraham, Priya

    2011-09-01

    Virological monitoring of hepatitis B virus (HBV) DNA is critical to the management of HBV infection. With several HBV DNA quantification assays available, it is important to use the most efficient testing system for virological monitoring. In this study, we evaluated the performance characteristics and comparability of three HBV DNA quantification systems: Abbott HBV real-time PCR (Abbott PCR), artus HBV real-time PCR with QIAamp DNA blood kit purification (artus-DB), and artus HBV real-time PCR with the QIAamp DSP virus kit purification (artus-DSP). The lower limits of detection of these systems were established against the WHO international standards for HBV DNA and were found to be 1.43, 82, and 9 IU/ml, respectively. The intra-assay and interassay coefficients of variation of plasma samples (1 to 6 log(10) IU/ml) ranged between 0.05 to 8.34% and 0.16 to 3.48% for the Abbott PCR, 1.53 to 26.85% and 0.50 to 12.89% for artus-DB, and 0.29 to 7.42% and 0.94 to 3.01% for artus-DSP, respectively. Ninety HBV clinical samples were used for comparison of assays, and paired quantitative results showed strong correlation by linear regression analysis (artus-DB with Abbott PCR, r = 0.95; Abbott PCR with artus-DSP, r = 0.97; and artus-DSP with artus-DB, r = 0.94). Bland-Altman analysis showed a good level of agreement for Abbott PCR and artus-DSP, with a mean difference of 0.10 log(10) IU/ml and limits of agreement of -0.91 to 1.11 log(10) IU/ml. No genotype-specific bias was seen in all three systems for HBV genotypes A, C, and D, which are predominant in this region. This finding illustrates that the Abbott real-time HBV and artus-DSP systems show more comparable performance than the artus-DB system, meeting the current guidelines for assays to be used in the management of hepatitis B.

  9. Bacterial recovery from breast skin of genetically feathered and featherless broiler carcasses immediately following scalding and picking.

    PubMed

    Buhr, R J; Berrang, M E; Cason, J A

    2003-10-01

    Genetically feathered and featherless sibling broilers selected for matched BW were killed, scalded, and defeathered to determine the consequences of feathers and empty feather follicles on the recovery of bacteria from carcass breast skin. In trial 1, the vents of all carcasses were plugged and sutured before scalding to prevent the expulsion of cloacal contents during picking. In trial 2, half of the carcasses had their vents plugged and sutured. Immediately after defeathering, breast skin was aseptically removed, and bacteria associated with it were enumerated. In trial 1, the levels of bacteria recovered did not differ between feathered and featherless carcasses: Campylobacter log10 1.4 cfu/mL of rinse, coliform log10 1.8, Escherichia coli log10 1.6, and total aerobic bacteria log10 3.1. In trial 2, the carcasses that had vents plugged and sutured had lower levels of all four types of bacteria (differences of Campylobacter log10 0.7 cfu/mL, coliform log10 1.8, E. coli log10 1.7, and total aerobic bacteria log10 0.5) than those carcasses with open vents. The lower levels of bacteria recovered from carcasses with the vents plugged and sutured during picking enabled detection of small but significant differences between feathered and featherless carcasses. The level of coliform and E. coli recovered was slightly higher by log10 0.7 cfu for feathered carcasses, but featherless carcasses had marginally higher levels of total aerobic bacteria by log10 0.4 cfu. Feathered and featherless carcasses with open vents during picking did not differ in the levels of recovery of coliform, E. coli, and total aerobic bacteria from breast skin.

  10. Well log characterization of natural gas-hydrates

    USGS Publications Warehouse

    Collett, Timothy S.; Lee, Myung W.

    2012-01-01

    In the last 25 years there have been significant advancements in the use of well-logging tools to acquire detailed information on the occurrence of gas hydrates in nature: whereas wireline electrical resistivity and acoustic logs were formerly used to identify gas-hydrate occurrences in wells drilled in Arctic permafrost environments, more advanced wireline and logging-while-drilling (LWD) tools are now routinely used to examine the petrophysical nature of gas-hydrate reservoirs and the distribution and concentration of gas hydrates within various complex reservoir systems. Resistivity- and acoustic-logging tools are the most widely used for estimating the gas-hydrate content (i.e., reservoir saturations) in various sediment types and geologic settings. Recent integrated sediment coring and well-log studies have confirmed that electrical-resistivity and acoustic-velocity data can yield accurate gas-hydrate saturations in sediment grain-supported (isotropic) systems such as sand reservoirs, but more advanced log-analysis models are required to characterize gas hydrate in fractured (anisotropic) reservoir systems. New well-logging tools designed to make directionally oriented acoustic and propagation-resistivity log measurements provide the data needed to analyze the acoustic and electrical anisotropic properties of both highly interbedded and fracture-dominated gas-hydrate reservoirs. Advancements in nuclear magnetic resonance (NMR) logging and wireline formation testing (WFT) also allow for the characterization of gas hydrate at the pore scale. Integrated NMR and formation testing studies from northern Canada and Alaska have yielded valuable insight into how gas hydrates are physically distributed in sediments and the occurrence and nature of pore fluids(i.e., free water along with clay- and capillary-bound water) in gas-hydrate-bearing reservoirs. Information on the distribution of gas hydrate at the pore scale has provided invaluable insight on the mechanisms controlling the formation and occurrence of gas hydrate in nature along with data on gas-hydrate reservoir properties (i.e., porosities and permeabilities) needed to accurately predict gas production rates for various gas-hydrate production schemes.

  11. Target recognition of log-polar ladar range images using moment invariants

    NASA Astrophysics Data System (ADS)

    Xia, Wenze; Han, Shaokun; Cao, Jie; Yu, Haoyong

    2017-01-01

    The ladar range image has received considerable attentions in the automatic target recognition field. However, previous research does not cover target recognition using log-polar ladar range images. Therefore, we construct a target recognition system based on log-polar ladar range images in this paper. In this system combined moment invariants and backpropagation neural network are selected as shape descriptor and shape classifier, respectively. In order to fully analyze the effect of log-polar sampling pattern on recognition result, several comparative experiments based on simulated and real range images are carried out. Eventually, several important conclusions are drawn: (i) if combined moments are computed directly by log-polar range images, translation, rotation and scaling invariant properties of combined moments will be invalid (ii) when object is located in the center of field of view, recognition rate of log-polar range images is less sensitive to the changing of field of view (iii) as object position changes from center to edge of field of view, recognition performance of log-polar range images will decline dramatically (iv) log-polar range images has a better noise robustness than Cartesian range images. Finally, we give a suggestion that it is better to divide field of view into recognition area and searching area in the real application.

  12. Semi-inclusive wino and higgsino annihilation to LL'

    DOE PAGES

    Baumgart, Matthew; Vaidya, Varun

    2016-03-31

    Here, we systematically compute the annihilation rate for winos and higgsinos into the final state relevant for indirect detection experiments, γ + X. The radiative corrections to this process receive enhancement from the large Bloch-Nordsieck-Violating Sudakov logarithm, log(2Mmore » $${\\chi }$$/M W). We resum the double logs and include single logs to fixed order using a formalism that combines nonrelativistic and soft-collinear effective field theories. For the wino case, we update an earlier exclusion adapting results of the HESS experiment. At the thermal relic mass of 3 TeV, LL' corrections result in a ~30% reduction in rate relative to LL. But, single logs do not save the wino, and it is still excluded by an order of magnitude. Finally, experimental cuts produce an endpoint region which, our results show, significantly effects the higgsino rate at its thermal-relic mass near 1 TeV and is deserving of further study.« less

  13. A legacy of low-impact logging does not elevate prevalence of potentially pathogenic protozoa in free-ranging gorillas and chimpanzees in the Republic of Congo: logging and parasitism in African apes.

    PubMed

    Gillespie, Thomas R; Morgan, David; Deutsch, J Charlie; Kuhlenschmidt, Mark S; Salzer, Johanna S; Cameron, Kenneth; Reed, Trish; Sanz, Crickette

    2009-12-01

    Many studies have examined the long-term effects of selective logging on the abundance and diversity of free-ranging primates. Logging is known to reduce the abundance of some primate species through associated hunting and the loss of food trees for frugivores; however, the potential role of pathogens in such primate population declines is largely unexplored. Selective logging results in a suite of alterations in host ecology and forest structure that may alter pathogen dynamics in resident wildlife populations. In addition, environmental pollution with human fecal material may present a risk for wildlife infections with zoonotic protozoa, such as Cryptosporidium and Giardia. To better understand this interplay, we compared patterns of infection with these potentially pathogenic protozoa in sympatric western lowland gorillas (Gorilla gorilla gorilla) and chimpanzees (Pan troglodytes troglodytes) in the undisturbed Goualougo Triangle of Nouabalé-Ndoki National Park and the adjacent previously logged Kabo Concession in northern Republic of Congo. No Cryptosporidium infections were detected in any of the apes examined and prevalence of infection with Giardia was low (3.73% overall) and did not differ between logged and undisturbed forest for chimpanzees or gorillas. These results provide a baseline for prevalence of these protozoa in forest-dwelling African apes and suggest that low-intensity logging may not result in long-term elevated prevalence of potentially pathogenic protozoa.

  14. A Legacy of Low-Impact Logging does not Elevate Prevalence of Potentially Pathogenic Protozoa in Free-Ranging Gorillas and Chimpanzees in the Republic of Congo: Logging and Parasitism in African Apes

    PubMed Central

    Morgan, David; Deutsch, J. Charlie; Kuhlenschmidt, Mark S.; Salzer, Johanna S.; Cameron, Kenneth; Reed, Trish; Sanz, Crickette

    2010-01-01

    Many studies have examined the long-term effects of selective logging on the abundance and diversity of free-ranging primates. Logging is known to reduce the abundance of some primate species through associated hunting and the loss of food trees for frugivores; however, the potential role of pathogens in such primate population declines is largely unexplored. Selective logging results in a suite of alterations in host ecology and forest structure that may alter pathogen dynamics in resident wildlife populations. In addition, environmental pollution with human fecal material may present a risk for wildlife infections with zoonotic protozoa, such as Cryptosporidium and Giardia. To better understand this interplay, we compared patterns of infection with these potentially pathogenic protozoa in sympatric western lowland gorillas (Gorilla gorilla gorilla) and chimpanzees (Pan troglodytes troglodytes) in the undisturbed Goualougo Triangle of Nouabalé-Ndoki National Park and the adjacent previously logged Kabo Concession in northern Republic of Congo. No Cryptosporidium infections were detected in any of the apes examined and prevalence of infection with Giardia was low (3.73% overall) and did not differ between logged and undisturbed forest for chimpanzees or gorillas. These results provide a baseline for prevalence of these protozoa in forest-dwelling African apes and suggest that low-intensity logging may not result in long-term elevated prevalence of potentially pathogenic protozoa. PMID:20238141

  15. External quality assessment on detection of hepatitis C virus RNA in clinical laboratories of China.

    PubMed

    Wang, Lu-nan; Zhang, Rui; Shen, Zi-yu; Chen, Wen-xiang; Li, Jin-ming

    2008-06-05

    As with many studies carried out in European countries, a quality assurance program has been established by the National Center for Clinical Laboratories in China (NCCL). The results showed that the external quality assessment significantly improves laboratory performance for quantitative evaluation of hepatitis C virus (HCV) RNA. Serum panels were delivered twice annually to the clinical laboratories which performed HCV RNA detection in China. Each panel made up of 5 coded samples. All laboratories were requested to carry out the detection within the required time period and report on testing results which contained qualitative and/or quantitative test findings, reagents used and relevant information about apparatus. All the positive samples were calibrated against the first International Standard for HCV RNA in a collaborative study and the range of comparison target value (TG) designated as +/- 0.5 log. The numbers of laboratories reporting on qualitative testing results for the first and second time external quality assessment were 168 and 167 in the year of 2003 and increased to 209 and 233 in 2007; the numbers of laboratories reporting on quantitative testing results were 134 and 147 in 2003 and rose to 340 and 339 in 2007. Deviation between the mean value for quantitative results at home in 2003 and the target value was above 0.5 log, which was comparatively high. By 2007, the target value was close to the national average except for the low concentrated specimens (10(3) IU/ml). The percentage of results within the range of GM +/- 0.5 log(10) varied from 8.2% to 93.5%. Some laboratories had some difficulties in the exact quantification of the lowest (3.00 log IU/ml) as well as of the highest viral levels (6.37 log IU/ml) values, very near to the limits of the dynamic range of the assays. The comparison of these results with the previous study confirms that a regular participation in external quality assessment (EQA) assures the achievement of a high proficiency level in the diagnosis of HCV infection. During the 5-year external quality assessment, sensitivity and accuracy of detection in most of the clinical laboratories have been evidently improved and the quality of kits has also been substantially improved.

  16. Modeling the detectability of vesicoureteral reflux using microwave radiometry.

    PubMed

    Arunachalam, Kavitha; Maccarini, Paolo F; De Luca, Valeria; Bardati, Fernando; Snow, Brent W; Stauffer, Paul R

    2010-09-21

    We present the modeling efforts on antenna design, frequency selection and receiver sensitivity estimation to detect vesicoureteral reflux (VUR) using microwave (MW) radiometry as warm urine from the bladder maintained at fever range temperature using a MW hyperthermia device reflows into the kidneys. The radiometer center frequency (f(c)), frequency band (Deltaf) and aperture radius (r(a)) of the physical antenna for kidney temperature monitoring are determined using a simplified universal antenna model with a circular aperture. Anatomical information extracted from the computed tomography (CT) images of children aged 4-6 years is used to construct a layered 3D tissue model. Radiometric antenna efficiency is evaluated in terms of the ratio of the power collected from the target at depth to the total power received by the antenna (eta). The power ratio of the theoretical antenna is used to design a microstrip log spiral antenna with directional radiation pattern over f(c) +/- Deltaf/2. Power received by the log spiral from the deep target is enhanced using a thin low-loss dielectric matching layer. A cylindrical metal cup is proposed to shield the antenna from electromagnetic interference (EMI). Transient thermal simulations are carried out to determine the minimum detectable change in the antenna brightness temperature (deltaT(B)) for 15-25 mL urine refluxes at 40-42 degrees C located 35 mm from the skin surface. Theoretical antenna simulations indicate maximum eta over 1.1-1.6 GHz for r(a) = 30-40 mm. Simulations of the 35 mm radius tapered log spiral yielded a higher power ratio over f(c) +/- Deltaf/2 for the 35-40 mm deep targets in the presence of an optimal matching layer. Radiometric temperature calculations indicate deltaT(B) 0.1 K for the 15 mL urine at 40 degrees C and 35 mm depth. Higher eta and deltaT(B) were observed for the antenna and matching layer inside the metal cup. Reflection measurements of the log spiral in a saline phantom are in agreement with the simulation data. The numerical study suggests that a radiometer with f(c) = 1.35 GHz, Deltaf = 500 MHz and detector sensitivity better than 0.1 K would be the appropriate tool to noninvasively detect VUR using the log spiral antenna.

  17. Volatile metabolite production of spoilage micro-organisms on a mixed-lettuce agar during storage at 7 degrees C in air and low oxygen atmosphere.

    PubMed

    Ragaert, P; Devlieghere, F; Devuyst, E; Dewulf, J; Van Langenhove, H; Debevere, J

    2006-11-01

    This paper describes the volatile metabolite production of spoilage bacteria (Pantoea agglomerans and Rahnella aquatilis) and spoilage yeasts (Pichia fermentans and Cryptococcus laurentii), previously isolated from mixed lettuce, on a simulation medium of shredded mixed lettuce (mixed-lettuce agar) both under air conditions and modified atmosphere (MA)-conditions at 7 degrees C. These latter conditions simulated the equilibrium modified atmosphere packaging, which is used to extend the shelf-life of shredded mixed lettuce. Besides volatile metabolites, organic acid metabolites and consumption of sugars were measured. Microbiological growth on the mixed-lettuce agar resulted in metabolite production and consumption of sugars. Bacteria and yeasts produced a range of volatile organic compounds both under air conditions and MA-conditions: ethanol, ethyl acetate, 2-methyl-1-propanol, 2-methyl-1-butanol, 3-methyl-1-butanol, 2,3-butanedione, 3-methyl-1-pentanol, 1-butanol and 1-hexanol. Under MA-conditions, 2-methyl-1-butanol, 3-methyl-1-butanol and ethanol were the first compounds that were detected in the headspace as being produced by the inoculated micro-organisms. In the case of the yeast P. fermentans, production of these compounds was detected from a count of 5.0+/-0.1 log cfu/cm(2) with a fast increase when exceeding 6.0-6.5 log cfu/cm(2). Unlike P. fermentans, the yeast C. laurentii showed a slow metabolism under MA-conditions, compared to air conditions. In the case of the bacteria, production of 2-methyl-1-butanol and 3-methyl-1-butanol was detected starting from a count of 6.7+/-0.1 log cfu/cm(2) in the case of R. aquatilis and from a count of 7.1+/-0.4 log cfu/cm(2) in the case of P. agglomerans with a fast increase when exceeding 8 log cfu/cm(2). No production of ethanol by the bacteria under MA-conditions was detected in contradiction to air conditions. It could be concluded that, if these counts are reached on the cut surfaces of shredded mixed lettuce which are simulated by the mixed-lettuce agar, sensorial quality of shredded mixed lettuce could be influenced by the microbiological production of metabolites.

  18. Modeling the detectability of vesicoureteral reflux using microwave radiometry

    NASA Astrophysics Data System (ADS)

    Arunachalam, Kavitha; Maccarini, Paolo F.; De Luca, Valeria; Bardati, Fernando; Snow, Brent W.; Stauffer, Paul R.

    2010-09-01

    We present the modeling efforts on antenna design, frequency selection and receiver sensitivity estimation to detect vesicoureteral reflux (VUR) using microwave (MW) radiometry as warm urine from the bladder maintained at fever range temperature using a MW hyperthermia device reflows into the kidneys. The radiometer center frequency (fc), frequency band (Δf) and aperture radius (ra) of the physical antenna for kidney temperature monitoring are determined using a simplified universal antenna model with a circular aperture. Anatomical information extracted from the computed tomography (CT) images of children aged 4-6 years is used to construct a layered 3D tissue model. Radiometric antenna efficiency is evaluated in terms of the ratio of the power collected from the target at depth to the total power received by the antenna (η). The power ratio of the theoretical antenna is used to design a microstrip log spiral antenna with directional radiation pattern over fc ± Δf/2. Power received by the log spiral from the deep target is enhanced using a thin low-loss dielectric matching layer. A cylindrical metal cup is proposed to shield the antenna from electromagnetic interference (EMI). Transient thermal simulations are carried out to determine the minimum detectable change in the antenna brightness temperature (δTB) for 15-25 mL urine refluxes at 40-42 °C located 35 mm from the skin surface. Theoretical antenna simulations indicate maximum η over 1.1-1.6 GHz for ra = 30-40 mm. Simulations of the 35 mm radius tapered log spiral yielded a higher power ratio over fc ± Δf/2 for the 35-40 mm deep targets in the presence of an optimal matching layer. Radiometric temperature calculations indicate δTB >= 0.1 K for the 15 mL urine at 40 °C and 35 mm depth. Higher η and δTB were observed for the antenna and matching layer inside the metal cup. Reflection measurements of the log spiral in a saline phantom are in agreement with the simulation data. The numerical study suggests that a radiometer with fc = 1.35 GHz, Δf = 500 MHz and detector sensitivity better than 0.1 K would be the appropriate tool to noninvasively detect VUR using the log spiral antenna.

  19. Effect of ozone on the microbiological status of five dried aromatic plants.

    PubMed

    Kazi, Martha; Parlapani, Foteini F; Boziaris, Ioannis S; Vellios, Evangelos K; Lykas, Christos

    2018-03-01

    Aromatic plants may be contaminated with a wide range of microorganisms, making them a potential health hazard when infused or added to ready-to-eat meals. To ensure safety, the effect of gaseous ozone treatment on the population of aerobic plate counts (APC), hygienic indicators (Escherichia coli, Enterococcus spp. and Enterobacteriaceae) and fungi was investigated for five dried aromatic plants: oregano, thyme, mountain tea, lemon verbena and chamomile. Selection, isolation and further fungi identification were based on the phenotypic and macro- and microscopic characteristics. Prior to ozonation, APC on five dried aromatic plants was in the range 5-7 log colony-forming units (CFU) g -1 . The APC exhibited a 4 log reduction, from around 6.5 to 2.5 in the case of oregano, and only a 1-2 log reduction for other herbs after 30 or 60 min of 4 ppm gaseous ozone treatment. Enterococcus spp. and E. coli were not detected on any of the tested dried aromatic plants. The fungi counts were 2-4 log CFU g -1 before ozonation. Aspergillus spp, Penicillium spp, Cladosporium spp, Alternaria spp, Fusarium spp., Ulocladium spp. and some unknown fungi were detected on plants before ozone treatment. Aspergillus spp. and/or Penicillium spp. were only detected on mountain tea and thyme plant material after 60 min of ozonation. The present study provides information about the efficiency of ozone on the microbial decontamination of dried aromatic plants. Treatment with gaseous ozone at 4 ppm for 30 min in the case of dried oregano and 60 min in the case of chamomile and lemon verbena could be used as alternative disinfection methods. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  20. Activity of Tedizolid in Methicillin-Resistant Staphylococcus epidermidis Experimental Foreign Body-Associated Osteomyelitis.

    PubMed

    Park, Kyung-Hwa; Greenwood-Quaintance, Kerryl E; Schuetz, Audrey N; Mandrekar, Jayawant N; Patel, Robin

    2017-02-01

    We developed a rat model of methicillin-resistant Staphylococcus epidermidis (MRSE) foreign body-associated osteomyelitis and used it to compare tedizolid alone and in combination with rifampin against rifampin alone, vancomycin plus rifampin, and vancomycin alone. A clinical strain of MRSE was inoculated into the proximal tibia, and a stainless steel wire with a precolonized MRSE biofilm was implanted. Following a 1-week infection period, 92 rats received either no treatment (n = 17) or 14 days of intraperitoneal tedizolid (n = 15), tedizolid plus rifampin (n = 15), rifampin (n = 15), vancomycin plus rifampin (n = 15), or vancomycin (n = 15). Quantitative bone and wire cultures were performed after treatment completion and also 1 week after infection in a separate group of five rats. The median quantity of staphylococci in bone after the 1-week infection period was 4.89 log 10 CFU/g bone (interquartile range, 3.83 to 5.33 log 10 CFU/g bone); staphylococci were recovered from all associated wires. A median quantity of staphylococci of 3.70 log 10 CFU/g bone was detected in bones of untreated control rats after 3 weeks. Quantities of staphylococci in bones of all treatment groups except the group receiving vancomycin alone (2.78 log 10 CFU/g) were significantly lower than those for untreated controls, with no staphylococci being detected in the groups receiving rifampin monotherapy, tedizolid-plus-rifampin combination therapy, and vancomycin-plus-rifampin combination therapy. Quantities of staphylococci on wires from all treatment groups that included rifampin were significantly lower than those for untreated controls. No resistance to rifampin, tedizolid, or vancomycin was detected. Tedizolid combined with rifampin was active in a rat model of MRSE foreign body-associated osteomyelitis. Copyright © 2017 American Society for Microbiology.

  1. Uptake and Disposition of Select Pharmaceuticals by Bluegill Exposed at Constant Concentrations in a Flow-Through Aquatic Exposure System.

    PubMed

    Zhao, Jian-Liang; Furlong, Edward T; Schoenfuss, Heiko L; Kolpin, Dana W; Bird, Kyle L; Feifarek, David J; Schwab, Eric A; Ying, Guang-Guo

    2017-04-18

    The increasing use of pharmaceuticals has led to their subsequent input into and release from wastewater treatment plants, with corresponding discharge into surface waters that may subsequently exert adverse effects upon aquatic organisms. Although the distribution of pharmaceuticals in surface water has been extensively studied, the details of uptake, internal distribution, and kinetic processing of pharmaceuticals in exposed fish have received less attention. For this research, we investigated the uptake, disposition, and toxicokinetics of five pharmaceuticals (diclofenac, methocarbamol, rosuvastatin, sulfamethoxazole, and temazepam) in bluegill sunfish (Lepomis macrochirus) exposed to environmentally relevant concentrations (1000-4000 ng L -1 ) in a flow-through exposure system. Temazepam and methocarbamol were consistently detected in bluegill biological samples with the highest concentrations in bile of 4, 940, and 180 ng g -1 , respectively, while sulfamethoxazole, diclofenac, and rosuvastatin were only infrequently detected. Over 30-day exposures, the relative magnitude of mean concentrations of temazepam and methocarbamol in biological samples generally followed the order: bile ≫ gut > liver and brain > muscle, plasma, and gill. Ranges of bioconcentration factors (BCFs) in different biological samples were 0.71-3960 and 0.13-48.6 for temazepam and methocarbamol, respectively. Log BCFs were statistically positively correlated to pH adjusted log K ow (that is, log D ow ), with the strongest relations for liver and brain (r 2 = 0.92 and 0.99, respectively), implying that bioconcentration patterns of ionizable pharmaceuticals depend on molecular status, that is, whether a pharmaceutical is un-ionized or ionized at ambient tissue pH. Methocarbamol and temazepam underwent rapid uptake and elimination in bluegill biological compartments with uptake rate constants (K u ) and elimination rate constants (K e ) at 0.0066-0.0330 h -1 and 0.0075-0.0384 h -1 , respectively, and half-lives at 18.1-92.4 h. Exposure to mixtures of diclofenac, methocarbamol, sulfamethoxazole, and temazepam had little or no influence on the uptake and elimination rates, suggesting independent multiple uptake and disposition behaviors of pharmaceuticals by fish would occur when exposed to effluent-influenced surface waters.

  2. Uptake and disposition of select pharmaceuticals by bluegill exposed at constant concentrations in a flow-through aquatic exposure system

    USGS Publications Warehouse

    Zhao, Jian-Liang; Furlong, Edward T.; Schoenfuss, Heiko L.; Kolpin, Dana W.; Bird, Kyle L.; Feifarek, David J.; Schwab, Eric A.; Ying, Guang-Guo

    2017-01-01

    The increasing use of pharmaceuticals has led to their subsequent input into and release from wastewater treatment plants, with corresponding discharge into surface waters that may subsequently exert adverse effects upon aquatic organisms. Although the distribution of pharmaceuticals in surface water has been extensively studied, the details of uptake, internal distribution, and kinetic processing of pharmaceuticals in exposed fish have received less attention. For this research, we investigated the uptake, disposition, and toxicokinetics of five pharmaceuticals (diclofenac, methocarbamol, rosuvastatin, sulfamethoxazole, and temazepam) in bluegill sunfish (Lepomis macrochirus) exposed to environmentally relevant concentrations (1000–4000 ng L–1) in a flow-through exposure system. Temazepam and methocarbamol were consistently detected in bluegill biological samples with the highest concentrations in bile of 4, 940, and 180 ng g–1, respectively, while sulfamethoxazole, diclofenac, and rosuvastatin were only infrequently detected. Over 30-day exposures, the relative magnitude of mean concentrations of temazepam and methocarbamol in biological samples generally followed the order: bile ≫ gut > liver and brain > muscle, plasma, and gill. Ranges of bioconcentration factors (BCFs) in different biological samples were 0.71–3960 and 0.13–48.6 for temazepam and methocarbamol, respectively. Log BCFs were statistically positively correlated to pH adjusted log Kow (that is, log Dow), with the strongest relations for liver and brain (r2 = 0.92 and 0.99, respectively), implying that bioconcentration patterns of ionizable pharmaceuticals depend on molecular status, that is, whether a pharmaceutical is un-ionized or ionized at ambient tissue pH. Methocarbamol and temazepam underwent rapid uptake and elimination in bluegill biological compartments with uptake rate constants (Ku) and elimination rate constants (Ke) at 0.0066–0.0330 h–1 and 0.0075–0.0384 h–1, respectively, and half-lives at 18.1–92.4 h. Exposure to mixtures of diclofenac, methocarbamol, sulfamethoxazole, and temazepam had little or no influence on the uptake and elimination rates, suggesting independent multiple uptake and disposition behaviors of pharmaceuticals by fish would occur when exposed to effluent-influenced surface waters.

  3. Evaluation of a Rapid One-step Real-time PCR Method as a High-throughput Screening for Quantification of Hepatitis B Virus DNA in a Resource-limited Setting.

    PubMed

    Rashed-Ul Islam, S M; Jahan, Munira; Tabassum, Shahina

    2015-01-01

    Virological monitoring is the best predictor for the management of chronic hepatitis B virus (HBV) infections. Consequently, it is important to use the most efficient, rapid and cost-effective testing systems for HBV DNA quantification. The present study compared the performance characteristics of a one-step HBV polymerase chain reaction (PCR) vs the two-step HBV PCR method for quantification of HBV DNA from clinical samples. A total of 100 samples consisting of 85 randomly selected samples from patients with chronic hepatitis B (CHB) and 15 samples from apparently healthy individuals were enrolled in this study. Of the 85 CHB clinical samples tested, HBV DNA was detected from 81% samples by one-step PCR method with median HBV DNA viral load (VL) of 7.50 × 10 3 lU/ml. In contrast, 72% samples were detected by the two-step PCR system with median HBV DNA of 3.71 × 10 3 lU/ml. The one-step method showed strong linear correlation with two-step PCR method (r = 0.89; p < 0.0001). Both methods showed good agreement at Bland-Altman plot, with a mean difference of 0.61 log 10 IU/ml and limits of agreement of -1.82 to 3.03 log 10 IU/ml. The intra-assay and interassay coefficients of variation (CV%) of plasma samples (4-7 log 10 IU/ml) for the one-step PCR method ranged between 0.33 to 0.59 and 0.28 to 0.48 respectively, thus demonstrating a high level of concordance between the two methods. Moreover, elimination of the DNA extraction step in the one-step PCR kit allowed time-efficient and significant labor and cost savings for the quantification of HBV DNA in a resource limited setting. Rashed-Ul Islam SM, Jahan M, Tabassum S. Evaluation of a Rapid One-step Real-time PCR Method as a High-throughput Screening for Quantification of Hepatitis B Virus DNA in a Resource-limited Setting. Euroasian J Hepato-Gastroenterol 2015;5(1):11-15.

  4. Evaluation of a Rapid One-step Real-time PCR Method as a High-throughput Screening for Quantification of Hepatitis B Virus DNA in a Resource-limited Setting

    PubMed Central

    Jahan, Munira; Tabassum, Shahina

    2015-01-01

    Virological monitoring is the best predictor for the management of chronic hepatitis B virus (HBV) infections. Consequently, it is important to use the most efficient, rapid and cost-effective testing systems for HBV DNA quantification. The present study compared the performance characteristics of a one-step HBV polymerase chain reaction (PCR) vs the two-step HBV PCR method for quantification of HBV DNA from clinical samples. A total of 100 samples consisting of 85 randomly selected samples from patients with chronic hepatitis B (CHB) and 15 samples from apparently healthy individuals were enrolled in this study. Of the 85 CHB clinical samples tested, HBV DNA was detected from 81% samples by one-step PCR method with median HBV DNA viral load (VL) of 7.50 × 103 lU/ml. In contrast, 72% samples were detected by the two-step PCR system with median HBV DNA of 3.71 × 103 lU/ml. The one-step method showed strong linear correlation with two-step PCR method (r = 0.89; p < 0.0001). Both methods showed good agreement at Bland-Altman plot, with a mean difference of 0.61 log10 IU/ml and limits of agreement of -1.82 to 3.03 log10 IU/ml. The intra-assay and interassay coefficients of variation (CV%) of plasma samples (4-7 log10 IU/ml) for the one-step PCR method ranged between 0.33 to 0.59 and 0.28 to 0.48 respectively, thus demonstrating a high level of concordance between the two methods. Moreover, elimination of the DNA extraction step in the one-step PCR kit allowed time-efficient and significant labor and cost savings for the quantification of HBV DNA in a resource limited setting. How to cite this article Rashed-Ul Islam SM, Jahan M, Tabassum S. Evaluation of a Rapid One-step Real-time PCR Method as a High-throughput Screening for Quantification of Hepatitis B Virus DNA in a Resource-limited Setting. Euroasian J Hepato-Gastroenterol 2015;5(1):11-15. PMID:29201678

  5. Tree Diamter Effects on Cost and Productivity of Cut-to-Length Systems

    Treesearch

    Matthew A. Holtzscher; Bobby L. Lanford

    1997-01-01

    Currently, there is a lack of economic information concerning cut-to-length harvesting systems. This study examined and measured the different costs of operating cut-to-length logging equipment over a range of average stand diameters at breast height. Three different cut-to-length logging systems were examined in this study. Systems included: 1) felier-buncher/manual/...

  6. Fast WEP-Key Recovery Attack Using Only Encrypted IP Packets

    NASA Astrophysics Data System (ADS)

    Teramura, Ryoichi; Asakura, Yasuo; Ohigashi, Toshihiro; Kuwakado, Hidenori; Morii, Masakatu

    Conventional efficient key recovery attacks against Wired Equivalent Privacy (WEP) require specific initialization vectors or specific packets. Since it takes much time to collect the packets sufficiently, any active attack should be performed. An Intrusion Detection System (IDS), however, will be able to prevent the attack. Since the attack logs are stored at the servers, it is possible to prevent such an attack. This paper proposes an algorithm for recovering a 104-bit WEP key from any IP packets in a realistic environment. This attack needs about 36, 500 packets with a success probability 0.5, and the complexity of our attack is equivalent to about 220 computations of the RC4 key setups. Since our attack is passive, it is difficult for both WEP users and administrators to detect our attack.

  7. Magnetic susceptibility well-logging unit with single power supply thermoregulation system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seeley, R. L.

    1985-11-05

    The magnetic susceptibility well-logging unit with single power supply thermoregulation system provides power from a single surface power supply over a well-logging cable to an integrated circuit voltage regulator system downhole. This voltage regulator system supplies regulated voltages to a temperature control system and also to a Maxwell bridge sensing unit which includes the solenoid of a magnetic susceptibility probe. The temperature control system is provided with power from the voltage regulator system and operates to permit one of several predetermined temperatures to be chosen, and then operates to maintain the solenoid of a magnetic susceptibility probe at this chosenmore » temperature. The temperature control system responds to a temperature sensor mounted upon the probe solenoid to cause resistance heaters concentrically spaced from the probe solenoid to maintain the chosen temperature. A second temperature sensor on the probe solenoid provides a temperature signal to a temperature transmitting unit, which initially converts the sensed temperature to a representative voltage. This voltage is then converted to a representative current signal which is transmitted by current telemetry over the well logging cable to a surface electronic unit which then reconverts the current signal to a voltage signal.« less

  8. Interpretation of well logs in a carbonate aquifer

    USGS Publications Warehouse

    MacCary, L.M.

    1978-01-01

    This report describes the log analysis of the Randolph and Sabial core holes in the Edwards aquifer in Texas, with particular attention to the principles that can be applied generally to any carbonate system. The geologic and hydrologic data were obtained during the drilling of the two holes, from extensive laboratory analysis of the cores, and from numerous geophysical logs run in the two holes. Some logging methods are inherently superiors to others for the analysis of limestone and dolomite aquifers. Three such systems are the dentistry, neutron, and acoustic-velocity (sonic) logs. Most of the log analysis described here is based on the interpretation of suites of logs from these three systems. In certain instances, deeply focused resistivity logs can be used to good advantage in carbonate rock studies; this technique is used to computer the water resistivity in the Randolph core hole. The rocks penetrated by the Randolph core hole are typical of those carbonates that have undergone very little solution by recent ground-water circulation. There are few large solutional openings; the water is saline; and the rocks are dark, dolomitic, have pore space that is interparticle or intercrystalline, and contain unoxidized organic material. The total porosity of rocks in the saline zone is higher than that of rocks in the fresh-water aquifer; however, the intrinsic permeability is much less in the saline zone because there are fewer large solutional openings. The Sabinal core hole penetrates a carbonate environment that has experienced much solution by ground water during recent geologic time. The rocks have high secondary porosities controlled by sedimentary structures within the rock; the water is fresh; and the dominant rock composition is limestone. The relative percentages of limestone and dolomite, the average matrix (grain) densities of the rock mixtures , and the porosity of the rock mass can be calculated from density, neutron, and acoustic logs. With supporting data from resistivity logs, the formation water quality can be estimated, as well as the relative cementation or tortuosity of the rock. Many of these properties calculated from logs can be verified by analysis of the core available from test holes drilled in the saline and fresh water zones.

  9. Keck and VLT Observations of Super-Damped Lyman-Alpha Absorbers at z 2- 2.5: Constraints on Chemical Compositions and Physical Conditions

    NASA Astrophysics Data System (ADS)

    Kulkarni, Varsha P.; Som, Debopam; Morrison, Sean; Péroux, Celine; Quiret, Samuel; York, Donald G.

    2015-12-01

    We report Keck/Echellette Spectrograph and Imager and Very Large Telescope/Ultraviolet-Visual Echelle Spectrograph observations of three super-damped Lyα quasar absorbers with H i column densities log NH i ≥ 21.7 at redshifts 2 ≲ z ≲ 2.5. All three absorbers show similar metallicities (˜-1.3 to -1.5 dex), and dust depletion of Fe, Ni, and Mn. Two of the absorbers show supersolar [S/Zn] and [Si/Zn]. We combine our results with those for other damped Lyα a absorbers (DLAs) to examine trends between NH i, metallicity, and dust depletion. A larger fraction of the super-DLAs lie close to or above the line [X/H] = 20.59 - log NH i in the metallicity versus NH i plot, compared to the less gas-rich DLAs, suggesting that super-DLAs are more likely to be rich in molecules. Unfortunately, our data for Q0230-0334 and Q0743+1421 do not cover H2 absorption lines. For Q1418+0718, some H2 lines are covered, but not detected. CO is not detected in any of our absorbers. For DLAs with log NH i < 21.7, we confirm strong correlation between metallicity and Fe depletion, and find a correlation between metallicity and Si depletion. For super-DLAs, these correlations are weaker or absent. The absorbers toward Q0230-0334 and Q1418+0718 show potential detections of weak Lyα emission, implying star formation rates of ˜1.6 and ˜0.7 M⊙ yr-1, respectively (ignoring dust extinction). Upper limits on the electron densities from C ii*/C ii or Si ii*/Si ii are low, but are higher than the median values in less gas-rich DLAs. Finally, systems with log NH i > 21.7 may have somewhat narrower velocity dispersions Δv90 than the less gas-rich DLAs, and may arise in cooler and/or less turbulent gas. Includes observations collected during program ESO 93.A-0422 at the European Southern Observatory (ESO) Very Large Telescope (VLT) with the Ultraviolet-Visual Echelle Spectrograph (UVES) on the 8.2 m telescopes operated at the Paranal Observatory, Chile. Some of the data presented herein were obtained at the W.M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and the National Aeronautics and Space Administration. The Observatory was made possible by the generous financial support of the W.M. Keck Foundation.

  10. Use of propidium monoazide for the enumeration of viable Brettanomyces bruxellensis in wine and beer by quantitative PCR.

    PubMed

    Vendrame, Marco; Manzano, Marisa; Comi, Giuseppe; Bertrand, Julien; Iacumin, Lucilla

    2014-09-01

    Brettanomyces bruxellensis is a current problem in winemaking all over the world, and the question if B. bruxellensis has a positive or negative impact on wine is one of the most controversial discussions in the world. The presence of live B. bruxellensis cells represents the risk of growth and an increase in cell numbers, which is related to the potential production of volatile phenols. In this work, the optimisation of a PMA-quantitative PCR (qPCR) method to enumerate only viable cells was carried out using the standard strain B. bruxellensis DSMZ 70726. The obtained detection limits were 0.83 log CFU/mL in red wine, 0.63 log CFU/mL in white wine and 0.23 log CFU/mL in beer. Moreover, the quantification was also performed by Reverse Transcription quantitative PCR (RT-qPCR), and the results showed a higher detection limit for all of the trials. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Geology of the surficial aquifer system, Dade County, Florida; lithologic logs

    USGS Publications Warehouse

    Causaras, C.R.

    1986-01-01

    The geologic framework of the surficial aquifer system in Dade County, Florida, was investigated as part of a longterm study by the USGS in cooperation with the South Florida Water Management District, to describe the geology, hydrologic characteristics, and groundwater quality of the surficial aquifer system. Thirty-three test wells were drilled completely through the surficial aquifer system and into the underlying, relatively impermeable units of the Tamiami and Hawthorn Formations. Detailed lithologic logs were made from microscopic examination of rock cuttings and cores obtained from these wells. The logs were used to prepare geologic sections that show the lithologic variations, thickness of the lithologic units, and different geologic formations that comprise the aquifers system. (Author 's abstract)

  12. Lumber Values from Computerized Simulation of Hardwood Log Sawing.

    DTIC Science & Technology

    1980-01-01

    and the which is sawed into boards by parallel centered detective core area . saw cuts (fig. 2). (M 141650) report. Details of how the computer programs...sawing hardwood logs that do will have a somewhat lower production and each market area . It should also be not have an excessive amount of heart rot...species where sapwood and cant, and decision) tended to yield similar Its disadvantages are high initial cost, heartwood are priced differently, live

  13. Odor, gaseous and PM10 emissions from small scale combustion of wood types indigenous to Central Europe

    PubMed Central

    Kistler, Magdalena; Schmidl, Christoph; Padouvas, Emmanuel; Giebl, Heinrich; Lohninger, Johann; Ellinger, Reinhard; Bauer, Heidi; Puxbaum, Hans

    2012-01-01

    In this study, we investigated the emissions, including odor, from log wood stoves, burning wood types indigenous to mid-European countries such as Austria, Czech Republic, Hungary, Slovak Republic, Slovenia, Switzerland, as well as Baden-Württemberg and Bavaria (Germany) and South Tyrol (Italy). The investigations were performed with a modern, certified, 8 kW, manually fired log wood stove, and the results were compared to emissions from a modern 9 kW pellet stove. The examined wood types were deciduous species: black locust, black poplar, European hornbeam, European beech, pedunculate oak (also known as “common oak”), sessile oak, turkey oak and conifers: Austrian black pine, European larch, Norway spruce, Scots pine, silver fir, as well as hardwood briquettes. In addition, “garden biomass” such as pine cones, pine needles and dry leaves were burnt in the log wood stove. The pellet stove was fired with softwood pellets. The composite average emission rates for log wood and briquettes were 2030 mg MJ−1 for CO; 89 mg MJ−1 for NOx, 311 mg MJ−1 for CxHy, 67 mg MJ−1 for particulate matter PM10 and average odor concentration was at 2430 OU m−3. CO, CxHy and PM10 emissions from pellets combustion were lower by factors of 10, 13 and 3, while considering NOx – comparable to the log wood emissions. Odor from pellets combustion was not detectable. CxHy and PM10 emissions from garden biomass (needles and leaves) burning were 10 times higher than for log wood, while CO and NOx rise only slightly. Odor levels ranged from not detectable (pellets) to around 19,000 OU m−3 (dry leaves). The odor concentration correlated with CO, CxHy and PM10. For log wood combustion average odor ranged from 536 OU m−3 for hornbeam to 5217 OU m−3 for fir, indicating a considerable influence of the wood type on odor concentration. PMID:23471123

  14. Odor, gaseous and PM10 emissions from small scale combustion of wood types indigenous to Central Europe.

    PubMed

    Kistler, Magdalena; Schmidl, Christoph; Padouvas, Emmanuel; Giebl, Heinrich; Lohninger, Johann; Ellinger, Reinhard; Bauer, Heidi; Puxbaum, Hans

    2012-05-01

    In this study, we investigated the emissions, including odor, from log wood stoves, burning wood types indigenous to mid-European countries such as Austria, Czech Republic, Hungary, Slovak Republic, Slovenia, Switzerland, as well as Baden-Württemberg and Bavaria (Germany) and South Tyrol (Italy). The investigations were performed with a modern, certified, 8 kW, manually fired log wood stove, and the results were compared to emissions from a modern 9 kW pellet stove. The examined wood types were deciduous species: black locust, black poplar, European hornbeam, European beech, pedunculate oak (also known as "common oak"), sessile oak, turkey oak and conifers: Austrian black pine, European larch, Norway spruce, Scots pine, silver fir, as well as hardwood briquettes. In addition, "garden biomass" such as pine cones, pine needles and dry leaves were burnt in the log wood stove. The pellet stove was fired with softwood pellets. The composite average emission rates for log wood and briquettes were 2030 mg MJ -1 for CO; 89 mg MJ -1 for NO x , 311 mg MJ -1 for C x H y , 67 mg MJ -1 for particulate matter PM 10 and average odor concentration was at 2430 OU m -3 . CO, C x H y and PM 10 emissions from pellets combustion were lower by factors of 10, 13 and 3, while considering NO x - comparable to the log wood emissions. Odor from pellets combustion was not detectable. C x H y and PM10 emissions from garden biomass (needles and leaves) burning were 10 times higher than for log wood, while CO and NO x rise only slightly. Odor levels ranged from not detectable (pellets) to around 19,000 OU m -3 (dry leaves). The odor concentration correlated with CO, C x H y and PM 10 . For log wood combustion average odor ranged from 536 OU m -3 for hornbeam to 5217 OU m -3 for fir, indicating a considerable influence of the wood type on odor concentration.

  15. A log-Weibull spatial scan statistic for time to event data.

    PubMed

    Usman, Iram; Rosychuk, Rhonda J

    2018-06-13

    Spatial scan statistics have been used for the identification of geographic clusters of elevated numbers of cases of a condition such as disease outbreaks. These statistics accompanied by the appropriate distribution can also identify geographic areas with either longer or shorter time to events. Other authors have proposed the spatial scan statistics based on the exponential and Weibull distributions. We propose the log-Weibull as an alternative distribution for the spatial scan statistic for time to events data and compare and contrast the log-Weibull and Weibull distributions through simulation studies. The effect of type I differential censoring and power have been investigated through simulated data. Methods are also illustrated on time to specialist visit data for discharged patients presenting to emergency departments for atrial fibrillation and flutter in Alberta during 2010-2011. We found northern regions of Alberta had longer times to specialist visit than other areas. We proposed the spatial scan statistic for the log-Weibull distribution as a new approach for detecting spatial clusters for time to event data. The simulation studies suggest that the test performs well for log-Weibull data.

  16. Narrow log-periodic modulations in non-Markovian random walks

    NASA Astrophysics Data System (ADS)

    Diniz, R. M. B.; Cressoni, J. C.; da Silva, M. A. A.; Mariz, A. M.; de Araújo, J. M.

    2017-12-01

    What are the necessary ingredients for log-periodicity to appear in the dynamics of a random walk model? Can they be subtle enough to be overlooked? Previous studies suggest that long-range damaged memory and negative feedback together are necessary conditions for the emergence of log-periodic oscillations. The role of negative feedback would then be crucial, forcing the system to change direction. In this paper we show that small-amplitude log-periodic oscillations can emerge when the system is driven by positive feedback. Due to their very small amplitude, these oscillations can easily be mistaken for numerical finite-size effects. The models we use consist of discrete-time random walks with strong memory correlations where the decision process is taken from memory profiles based either on a binomial distribution or on a delta distribution. Anomalous superdiffusive behavior and log-periodic modulations are shown to arise in the large time limit for convenient choices of the models parameters.

  17. Analyzing engagement in a web-based intervention platform through visualizing log-data.

    PubMed

    Morrison, Cecily; Doherty, Gavin

    2014-11-13

    Engagement has emerged as a significant cross-cutting concern within the development of Web-based interventions. There have been calls to institute a more rigorous approach to the design of Web-based interventions, to increase both the quantity and quality of engagement. One approach would be to use log-data to better understand the process of engagement and patterns of use. However, an important challenge lies in organizing log-data for productive analysis. Our aim was to conduct an initial exploration of the use of visualizations of log-data to enhance understanding of engagement with Web-based interventions. We applied exploratory sequential data analysis to highlight sequential aspects of the log data, such as time or module number, to provide insights into engagement. After applying a number of processing steps, a range of visualizations were generated from the log-data. We then examined the usefulness of these visualizations for understanding the engagement of individual users and the engagement of cohorts of users. The visualizations created are illustrated with two datasets drawn from studies using the SilverCloud Platform: (1) a small, detailed dataset with interviews (n=19) and (2) a large dataset (n=326) with 44,838 logged events. We present four exploratory visualizations of user engagement with a Web-based intervention, including Navigation Graph, Stripe Graph, Start-Finish Graph, and Next Action Heat Map. The first represents individual usage and the last three, specific aspects of cohort usage. We provide examples of each with a discussion of salient features. Log-data analysis through data visualization is an alternative way of exploring user engagement with Web-based interventions, which can yield different insights than more commonly used summative measures. We describe how understanding the process of engagement through visualizations can support the development and evaluation of Web-based interventions. Specifically, we show how visualizations can (1) allow inspection of content or feature usage in a temporal relationship to the overall program at different levels of granularity, (2) detect different patterns of use to consider personalization in the design process, (3) detect usability issues, (4) enable exploratory analysis to support the design of statistical queries to summarize the data, (5) provide new opportunities for real-time evaluation, and (6) examine assumptions about interactivity that underlie many summative measures in this field.

  18. Analyzing Engagement in a Web-Based Intervention Platform Through Visualizing Log-Data

    PubMed Central

    2014-01-01

    Background Engagement has emerged as a significant cross-cutting concern within the development of Web-based interventions. There have been calls to institute a more rigorous approach to the design of Web-based interventions, to increase both the quantity and quality of engagement. One approach would be to use log-data to better understand the process of engagement and patterns of use. However, an important challenge lies in organizing log-data for productive analysis. Objective Our aim was to conduct an initial exploration of the use of visualizations of log-data to enhance understanding of engagement with Web-based interventions. Methods We applied exploratory sequential data analysis to highlight sequential aspects of the log data, such as time or module number, to provide insights into engagement. After applying a number of processing steps, a range of visualizations were generated from the log-data. We then examined the usefulness of these visualizations for understanding the engagement of individual users and the engagement of cohorts of users. The visualizations created are illustrated with two datasets drawn from studies using the SilverCloud Platform: (1) a small, detailed dataset with interviews (n=19) and (2) a large dataset (n=326) with 44,838 logged events. Results We present four exploratory visualizations of user engagement with a Web-based intervention, including Navigation Graph, Stripe Graph, Start–Finish Graph, and Next Action Heat Map. The first represents individual usage and the last three, specific aspects of cohort usage. We provide examples of each with a discussion of salient features. Conclusions Log-data analysis through data visualization is an alternative way of exploring user engagement with Web-based interventions, which can yield different insights than more commonly used summative measures. We describe how understanding the process of engagement through visualizations can support the development and evaluation of Web-based interventions. Specifically, we show how visualizations can (1) allow inspection of content or feature usage in a temporal relationship to the overall program at different levels of granularity, (2) detect different patterns of use to consider personalization in the design process, (3) detect usability issues, (4) enable exploratory analysis to support the design of statistical queries to summarize the data, (5) provide new opportunities for real-time evaluation, and (6) examine assumptions about interactivity that underlie many summative measures in this field. PMID:25406097

  19. Detection of gas hydrate with downhole logs and assessment of gas hydrate concentrations (saturations) and gas volumes on the Blake Ridge with electrical resistivity log data

    USGS Publications Warehouse

    Collett, T.S.; Ladd, J.

    2000-01-01

    Let 164 of the Ocean Drilling Program was designed to investigate the occurrence of gas hydrate in the sedimentary section beneath the Blake Ridge on the southeastern continental margin of North America. Site 994, and 997 were drilled on the Blake Ridge to refine our understanding of the in situ characteristics of natural gas hydrate. Because gas hydrate is unstable at surface pressure and temperature conditions, a major emphasis was placed on the downhole logging program to determine the in situ physical properties of the gas hydrate-bearing sediments. Downhole logging tool strings deployed on Leg 164 included the Schlumberger quad-combination tool (NGT, LSS/SDT, DIT, CNT-G, HLDT), the Formation MicroScanner (FMS), and the Geochemical Combination Tool (GST). Electrical resistivity (DIT) and acoustic transit-time (LSS/SDT) downhole logs from Sites 994, 995, and 997 indicate the presence of gas hydrate in the depth interval between 185 and 450 mbsf on the Blake Ridge. Electrical resistivity log calculations suggest that the gas hydrate-bearing sedimentary section on the Blake Ridge may contain between 2 and 11 percent bulk volume (vol%) gas hydrate. We have determined that the log-inferred gas hydrates and underlying free-gas accumulations on the Blake Ridge may contain as much as 57 trillion m3 of gas.

  20. Semi-quantitative assay for polyketide prymnesins isolated from Prymnesium parvum (Haptophyta) cultures.

    PubMed

    La Claire, J W; Manning, S R; Talarski, A E

    2015-08-01

    A fluorometric assay was developed to semi-quantify co-purified polyketide prymnesins-1 and -2 (PPs) from Prymnesium parvum cultures. Evaluations performed throughout the growth cycle of 5 practical salinity unit (PSU) cultures detected relatively 8-10 × more PPs in the culture medium (exotoxins) than in cells (endotoxins). The [exotoxin] remained stable and relatively low until post-log growth, when they increased significantly. However, on a per-cell basis, [exotoxin] declined throughout log phase and subsequently increased dramatically during late- and post-log phases. The [endotoxin] remained stable until late- and post-log phases, when it achieved its highest level before declining sharply. Shaking cultures of strains from Texas, South Carolina and the United Kingdom displayed dramatically different [exotoxin] during post-log decline. Cultures adapted to 30 PSU had significantly lower [exotoxin] over the course of cultivation than those grown at 5 PSU. Phosphate limitation enhanced [exotoxin] on a per-cell basis, especially in late- and post-log cultures. Media containing streptomycin exhibited a ∼20% increase in [exotoxin] in post-log cultures vs. control treatments, but it had only negligible effects on endotoxin levels. Brefeldin A had minimal effects on [exotoxin], suggesting that the presence of PPs in the medium may be largely derived from cell lysis or some other passive means. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Building analytical platform with Big Data solutions for log files of PanDA infrastructure

    NASA Astrophysics Data System (ADS)

    Alekseev, A. A.; Barreiro Megino, F. G.; Klimentov, A. A.; Korchuganova, T. A.; Maendo, T.; Padolski, S. V.

    2018-05-01

    The paper describes the implementation of a high-performance system for the processing and analysis of log files for the PanDA infrastructure of the ATLAS experiment at the Large Hadron Collider (LHC), responsible for the workload management of order of 2M daily jobs across the Worldwide LHC Computing Grid. The solution is based on the ELK technology stack, which includes several components: Filebeat, Logstash, ElasticSearch (ES), and Kibana. Filebeat is used to collect data from logs. Logstash processes data and export to Elasticsearch. ES are responsible for centralized data storage. Accumulated data in ES can be viewed using a special software Kibana. These components were integrated with the PanDA infrastructure and replaced previous log processing systems for increased scalability and usability. The authors will describe all the components and their configuration tuning for the current tasks, the scale of the actual system and give several real-life examples of how this centralized log processing and storage service is used to showcase the advantages for daily operations.

  2. Microbial contamination on beef and sheep carcases in South Australia.

    PubMed

    Sumner, John; Petrenas, Elena; Dean, Peter; Dowsett, Paul; West, Geoff; Wiering, Rinie; Raven, Geoff

    2003-03-25

    A total of 523 chilled beef and lamb carcases were sampled from four abattoirs and 13 very small plants (VSPs) in South Australia during March 2002 in order to develop a microbiological profile of meat produced for domestic consumption within the State. Aerobic viable counts (AVCs) and Escherichia coli counts were obtained from samples taken by sponge-sampling the muscle-adipose tissue at sites designated for each species in the Microbiological Guidelines to the Australian Standard for Hygienic Production of Meat for Human Consumption (identical with those of the USA Pathogen Reduction: hazard analysis and critical control point (HACCP) systems: final rule). On beef carcases (n=159) mean log AVC/cm(2) was 1.82 and E. coli was detected on 18.8% of carcases (area sampled 200 cm(2)) for which the mean log of the positives was -0.34; for lamb carcases, on which 75 cm(2) was sampled (n=364), corresponding values were 2.59, 36.2% and log(10) 0.27, respectively. There was little difference in mean log AVC/cm(2) of carcases produced at abattoirs and VSPs, 1.72 versus 1.81, respectively, for beef, and 2.80 versus 2.44, respectively, for sheep. Prevalence of E. coli was lower at VSPs, however, with abattoirs having 28.4% for beef and 61.5% for sheep, compared with corresponding values of 4.7% and 18.5% at VSPs. In VSPs, the range of mean log AVC/cm(2) was 0.47-3.16 for beef and 1.63-3.65 for sheep carcases, data which will allow the Controlling Authority to assist plants to improve performance of slaughter and dressing techniques. The present survey is part of an assessment by the State meat authority of the effectiveness of co-regulation of meat hygiene between government and industry.

  3. Identification of coal seam strata from geophysical logs of borehole using Adaptive Neuro-Fuzzy Inference System

    NASA Astrophysics Data System (ADS)

    Yegireddi, Satyanarayana; Uday Bhaskar, G.

    2009-01-01

    Different parameters obtained through well-logging geophysical sensors such as SP, resistivity, gamma-gamma, neutron, natural gamma and acoustic, help in identification of strata and estimation of the physical, electrical and acoustical properties of the subsurface lithology. Strong and conspicuous changes in some of the log parameters associated with any particular stratigraphy formation, are function of its composition, physical properties and help in classification. However some substrata show moderate values in respective log parameters and make difficult to identify or assess the type of strata, if we go by the standard variability ranges of any log parameters and visual inspection. The complexity increases further with more number of sensors involved. An attempt is made to identify the type of stratigraphy from borehole geophysical log data using a combined approach of neural networks and fuzzy logic, known as Adaptive Neuro-Fuzzy Inference System. A model is built based on a few data sets (geophysical logs) of known stratigraphy of in coal areas of Kothagudem, Godavari basin and further the network model is used as test model to infer the lithology of a borehole from their geophysical logs, not used in simulation. The results are very encouraging and the model is able to decipher even thin cola seams and other strata from borehole geophysical logs. The model can be further modified to assess the physical properties of the strata, if the corresponding ground truth is made available for simulation.

  4. Quality of the log-geometric distribution extrapolation for smaller undiscovered oil and gas pool size

    USGS Publications Warehouse

    Chenglin, L.; Charpentier, R.R.

    2010-01-01

    The U.S. Geological Survey procedure for the estimation of the general form of the parent distribution requires that the parameters of the log-geometric distribution be calculated and analyzed for the sensitivity of these parameters to different conditions. In this study, we derive the shape factor of a log-geometric distribution from the ratio of frequencies between adjacent bins. The shape factor has a log straight-line relationship with the ratio of frequencies. Additionally, the calculation equations of a ratio of the mean size to the lower size-class boundary are deduced. For a specific log-geometric distribution, we find that the ratio of the mean size to the lower size-class boundary is the same. We apply our analysis to simulations based on oil and gas pool distributions from four petroleum systems of Alberta, Canada and four generated distributions. Each petroleum system in Alberta has a different shape factor. Generally, the shape factors in the four petroleum systems stabilize with the increase of discovered pool numbers. For a log-geometric distribution, the shape factor becomes stable when discovered pool numbers exceed 50 and the shape factor is influenced by the exploration efficiency when the exploration efficiency is less than 1. The simulation results show that calculated shape factors increase with those of the parent distributions, and undiscovered oil and gas resources estimated through the log-geometric distribution extrapolation are smaller than the actual values. ?? 2010 International Association for Mathematical Geology.

  5. Decontamination of materials contaminated with Francisella philomiragia or MS2 bacteriophage using PES-Solid, a solid source of peracetic acid.

    PubMed

    Buhr, T L; Young, A A; Johnson, C A; Minter, Z A; Wells, C M

    2014-08-01

    The aim of the study was to develop test methods and evaluate survival of Francisella philomiragia cells and MS2 bacteriophage after exposure to PES-Solid (a solid source of peracetic acid) formulations with or without surfactants. Francisella philomiragia cells (≥7·6 log10 CFU) or MS2 bacteriophage (≥6·8 log10 PFU) were deposited on seven different test materials and treated with three different PES-Solid formulations, three different preneutralized samples and filter controls at room temperature for 15 min. There were 0-1·3 log10 CFU (<20 cells) of cell survival, or 0-1·7 log10 (<51 PFU) of bacteriophage survival in all 21 test combinations (organism, formulation and substrate) containing reactive PES-Solid. In addition, the microemulsion (Dahlgren Surfactant System) showed ≤2 log10 (100 cells) of viable F. philomiragia cells, indicating the microemulsion achieved <2 log10 CFU on its own. Three PES-Solid formulations and one microemulsion system (DSS) inactivated F. philomiragia cells and/or MS2 bacteriophage that were deposited on seven different materials. A test method was developed to show that reactive PES-Solid formulations and a microemulsion system (DSS) inactivated >6 log10 CFU/PFU F. philomiragia cells and/or MS2 bacteriophage on different materials. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  6. Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece

    PubMed Central

    2011-01-01

    Background HIV-1 is characterized by increased genetic heterogeneity which tends to hinder the reliability of detection and accuracy of HIV-1 RNA quantitation assays. Methods In this study, the Abbott RealTime HIV-1 (Abbott RealTime) assay was compared to the Roche Cobas TaqMan HIV-1 (Cobas TaqMan) and the Siemens Versant HIV-1 RNA 3.0 (bDNA 3.0) assays, using clinical samples of various viral load levels and subtypes from Greece, where the recent epidemiology of HIV-1 infection has been characterized by increasing genetic diversity and a marked increase in subtype A genetic strains among newly diagnosed infections. Results A high correlation was observed between the quantitative results obtained by the Abbott RealTime and the Cobas TaqMan assays. Viral load values quantified by the Abbott RealTime were on average lower than those obtained by the Cobas TaqMan, with a mean (SD) difference of -0.206 (0.298) log10 copies/ml. The mean differences according to HIV-1 subtypes between the two techniques for samples of subtype A, B, and non-A/non-B were 0.089, -0.262, and -0.298 log10 copies/ml, respectively. Overall, differences were less than 0.5 log10 for 85% of the samples, and >1 log10 in only one subtype B sample. Similarly, Abbott RealTime and bDNA 3.0 assays yielded a very good correlation of quantitative results, whereas viral load values assessed by the Abbott RealTime were on average higher (mean (SD) difference: 0.160 (0.287) log10 copies/ml). The mean differences according to HIV-1 subtypes between the two techniques for subtype A, B and non-A/non-B samples were 0.438, 0.105 and 0.191 log10 copies/ml, respectively. Overall, the majority of samples (86%) differed by less than 0.5 log10, while none of the samples showed a deviation of more than 1.0 log10. Conclusions In an area of changing HIV-1 subtype pattern, the Abbott RealTime assay showed a high correlation and good agreement of results when compared both to the Cobas TaqMan and bDNA 3.0 assays, for all HIV-1 subtypes tested. All three assays could determine viral load from samples of different HIV-1 subtypes adequately. However, assay variation should be taken into account when viral load monitoring of the same individual is assessed by different systems. PMID:21219667

  7. Identification and characterization of the active hydrothermal deposits in Okinawa Trough, SW Japan: Estimates from logging-while-drilling

    NASA Astrophysics Data System (ADS)

    Saito, S.; Sanada, Y.; Moe, K.; Kido, Y. N.; Hamada, Y.; Kumagai, H.; Nozaki, T.; Takai, K.; Suzuki, K.

    2015-12-01

    A scientific drilling expedition was conducted at an active hydrothermal field on the Iheya-North Knoll by D/V Chikyu in 2014 (Expedition 907) as a part of "Next-generation Technology for Ocean Resources Survey" of the Cross-ministerial Strategic Innovation Promotion Program. During the expedition logging while drilling (LWD) was deployed to constrain the area of the fluid reservoir beneath seafloor followed by three coring holes down to 150 meter below the seafloor (mbsf). The LWD system is composed of arcVISION for resistivity and natural gamma ray measurement and TeleScope for real-time transmission of drilling parameters and arcVISION data. Five sites (C9011-15) at the Iheya-North Original Site and one site (C9016) at Aki Site were drilled with LWD. At C9012 and C9016, the arcVISION detected temperature anomaly up to 84℃ at 234 mbsf and up to 39℃ at 80 mbsf, respectively. The temperature quickly increases at that depth and it would reflect the existence of high-temperature heat source along borehole. Due to the continuous fluid circulation during drilling, the measured temperature does not indicate in-situ temperature, but it reflects the heat disturbed by the cold circulated water instead. High quality resistivity and natural gamma ray data were acquired at six sites. The log curves at Site C9016 show characteristic response; the natural gamma ray log exhibits extremely high radiation (>500 gAPI) at 7-13 and 23-31 mbsf (Zone A). In the underlying interval of 31-40 mbsf, the resistivity log exhibits extremely low value (<0.2 ohm-m) (Zone B). Then the resistivity log exhibits higher value (~10 ohm-m) and the natural gamma ray log shows very low radiation (<50 gAPI) at the interval of 41-48 mbsf (Zone C). The log characteristics in Zone A, B, and C can be interpreted as a series of K-rich alteration zone, sulfide zone, and low-K hard (silicified) sediments, respectively. The LWD-based lithological interpretation was confirmed by the following core description. Zones A and B can be correlated to altered clay zone and sulfide zone including sphalerite, galena, chalcopyrite, and pyrite. Our results show that LWD is a powerful tool for the identification and characterization of submarine hydrothermal deposits and LWD survey enhances the successful recovery of sulfide samples.

  8. Rapid Detection of Mycobacterium tuberculosis and Rifampin Resistance by Use of On-Demand, Near-Patient Technology▿ † ‡

    PubMed Central

    Helb, Danica; Jones, Martin; Story, Elizabeth; Boehme, Catharina; Wallace, Ellen; Ho, Ken; Kop, JoAnn; Owens, Michelle R.; Rodgers, Richard; Banada, Padmapriya; Safi, Hassan; Blakemore, Robert; Lan, N. T. Ngoc; Jones-López, Edward C.; Levi, Michael; Burday, Michele; Ayakaka, Irene; Mugerwa, Roy D.; McMillan, Bill; Winn-Deen, Emily; Christel, Lee; Dailey, Peter; Perkins, Mark D.; Persing, David H.; Alland, David

    2010-01-01

    Current nucleic acid amplification methods to detect Mycobacterium tuberculosis are complex, labor-intensive, and technically challenging. We developed and performed the first analysis of the Cepheid Gene Xpert System's MTB/RIF assay, an integrated hands-free sputum-processing and real-time PCR system with rapid on-demand, near-patient technology, to simultaneously detect M. tuberculosis and rifampin resistance. Analytic tests of M. tuberculosis DNA demonstrated a limit of detection (LOD) of 4.5 genomes per reaction. Studies using sputum spiked with known numbers of M. tuberculosis CFU predicted a clinical LOD of 131 CFU/ml. Killing studies showed that the assay's buffer decreased M. tuberculosis viability by at least 8 logs, substantially reducing biohazards. Tests of 23 different commonly occurring rifampin resistance mutations demonstrated that all 23 (100%) would be identified as rifampin resistant. An analysis of 20 nontuberculosis mycobacteria species confirmed high assay specificity. A small clinical validation study of 107 clinical sputum samples from suspected tuberculosis cases in Vietnam detected 29/29 (100%) smear-positive culture-positive cases and 33/39 (84.6%) or 38/53 (71.7%) smear-negative culture-positive cases, as determined by growth on solid medium or on both solid and liquid media, respectively. M. tuberculosis was not detected in 25/25 (100%) of the culture-negative samples. A study of 64 smear-positive culture-positive sputa from retreatment tuberculosis cases in Uganda detected 63/64 (98.4%) culture-positive cases and 9/9 (100%) cases of rifampin resistance. Rifampin resistance was excluded in 54/55 (98.2%) susceptible cases. Specificity rose to 100% after correcting for a conventional susceptibility test error. In conclusion, this highly sensitive and simple-to-use system can detect M. tuberculosis directly from sputum in less than 2 h. PMID:19864480

  9. A Clinical Decision Support Engine Based on a National Medication Repository for the Detection of Potential Duplicate Medications: Design and Evaluation

    PubMed Central

    Yang, Cheng-Yi; Lo, Yu-Sheng; Chen, Ray-Jade

    2018-01-01

    Background A computerized physician order entry (CPOE) system combined with a clinical decision support system can reduce duplication of medications and thus adverse drug reactions. However, without infrastructure that supports patients’ integrated medication history across health care facilities nationwide, duplication of medication can still occur. In Taiwan, the National Health Insurance Administration has implemented a national medication repository and Web-based query system known as the PharmaCloud, which allows physicians to access their patients’ medication records prescribed by different health care facilities across Taiwan. Objective This study aimed to develop a scalable, flexible, and thematic design-based clinical decision support (CDS) engine, which integrates a national medication repository to support CPOE systems in the detection of potential duplication of medication across health care facilities, as well as to analyze its impact on clinical encounters. Methods A CDS engine was developed that can download patients’ up-to-date medication history from the PharmaCloud and support a CPOE system in the detection of potential duplicate medications. When prescribing a medication order using the CPOE system, a physician receives an alert if there is a potential duplicate medication. To investigate the impact of the CDS engine on clinical encounters in outpatient services, a clinical encounter log was created to collect information about time, prescribed drugs, and physicians’ responses to handling the alerts for each encounter. Results The CDS engine was installed in a teaching affiliate hospital, and the clinical encounter log collected information for 3 months, during which a total of 178,300 prescriptions were prescribed in the outpatient departments. In all, 43,844/178,300 (24.59%) patients signed the PharmaCloud consent form allowing their physicians to access their medication history in the PharmaCloud. The rate of duplicate medication was 5.83% (1843/31,614) of prescriptions. When prescribing using the CDS engine, the median encounter time was 4.3 (IQR 2.3-7.3) min, longer than that without using the CDS engine (median 3.6, IQR 2.0-6.3 min). From the physicians’ responses, we found that 42.06% (1908/4536) of the potential duplicate medications were recognized by the physicians and the medication orders were canceled. Conclusions The CDS engine could easily extend functions for detection of adverse drug reactions when more and more electronic health record systems are adopted. Moreover, the CDS engine can retrieve more updated and completed medication histories in the PharmaCloud, so it can have better performance for detection of duplicate medications. Although our CDS engine approach could enhance medication safety, it would make for a longer encounter time. This problem can be mitigated by careful evaluation of adopted solutions for implementation of the CDS engine. The successful key component of a CDS engine is the completeness of the patient’s medication history, thus further research to assess the factors in increasing the PharmaCloud consent rate is required. PMID:29351893

  10. Data processing and case identification in an agricultural and logging morbidity surveillance study: Trends over time.

    PubMed

    Scott, Erika; Bell, Erin; Krupa, Nicole; Hirabayashi, Liane; Jenkins, Paul

    2017-09-01

    Agriculture and logging are dangerous industries, and though data on fatal injury exists, less is known about non-fatal injury. Establishing a non-fatal injury surveillance system is a top priority. Pre-hospital care reports and hospitalization data were explored as a low-cost option for ongoing surveillance of occupational injury. Using pre-hospital care report free-text and location codes, along with hospital ICD-9-CM external cause of injury codes, we created a surveillance system that tracked farm and logging injuries. In Maine and New Hampshire, 1585 injury events were identified (2008-2010). The incidence of injuries was 12.4/1000 for agricultural workers, compared to 10.4/1000 to 12.2/1000 for logging workers. These estimates are consistent with other recent estimates. This system is limited to traumatic injury for which medical treatment is administered, and is limited by the accuracy of coding and spelling. This system has the potential to be both sustainable and low cost. © 2017 Wiley Periodicals, Inc.

  11. Endogenous System Microbes as Treatment Process ...

    EPA Pesticide Factsheets

    Monitoring the efficacy of treatment strategies to remove pathogens in decentralized systems remains a challenge. Evaluating log reduction targets by measuring pathogen levels is hampered by their sporadic and low occurrence rates. Fecal indicator bacteria are used in centralized systems to indicate the presence of fecal pathogens, but are ineffective decentralized treatment process indicators as they generally occur at levels too low to assess log reduction targets. System challenge testing by spiking with high loads of fecal indicator organisms, like MS2 coliphage, has limitations, especially for large systems. Microbes that are endogenous to the decentralized system, occur in high abundances and mimic removal rates of bacterial, viral and/or parasitic protozoan pathogens during treatment could serve as alternative treatment process indicators to verify log reduction targets. To identify abundant microbes in wastewater, the bacterial and viral communities were examined using deep sequencing. Building infrastructure-associated bacteria, like Zoogloea, were observed as dominant members of the bacterial community in graywater. In blackwater, bacteriophage of the order Caudovirales constituted the majority of contiguous sequences from the viral community. This study identifies candidate treatment process indicators in decentralized systems that could be used to verify log removal during treatment. The association of the presence of treatment process indic

  12. Detection of Ne VIII in an Intervening Multiphase Absorption System Toward 3C 263

    NASA Astrophysics Data System (ADS)

    Narayanan, Anand; Wakker, Bart P.; Savage, Blair D.

    2009-09-01

    We report the detection of Ne VIII in an intervening multiphase absorption line system at z = 0.32566 in the Far Ultraviolet Spectroscopic Explorer spectrum of the quasar 3C 263 (zem = 0.646). The Ne VIII λ770 Å detection has a 3.9σ significance. At the same velocity, we also find absorption lines from C IV, O III, O IV, and N IV. The line parameter measurements yield log [N(Ne VIII) cm-2] = 13.98+0.10 -0.13 and b = 49.8 ± 5.5 km s-1. We find that the ionization mechanism in the gas phase giving rise to the Ne VIII absorption is inconsistent with photoionization. The absorber has a multiphase structure, with the intermediate ions produced in cool photoionized gas and the Ne VIII most likely in a warm collisionally ionized medium in the temperature range (0.5-1.0) × 106 K. This is the second ever detection of an intervening Ne VIII absorption system. Its properties resemble the previous Ne VIII absorber reported by Savage and colleagues. Direct observations of H I and O VI are needed to better constrain the physical conditions in the collisionally ionized gas phase of this absorber. Based on observations with the NASA-CNES-CSA Far Ultraviolet Spectroscopic Explorer operated by Johns Hopkins University, supported by NASA contract NAS5-32985.

  13. Detection of vesicoureteral reflux using microwave radiometry-system characterization with tissue phantoms.

    PubMed

    Arunachalam, Kavitha; Maccarini, Paolo; De Luca, Valeria; Tognolatti, Piero; Bardati, Fernando; Snow, Brent; Stauffer, Paul

    2011-06-01

    Microwave (MW) radiometry is proposed for passive monitoring of kidney temperature to detect vesicoureteral reflux (VUR) of urine that is externally heated by a MW hyperthermia device and thereafter reflows from the bladder to kidneys during reflux. Here, we characterize in tissue-mimicking phantoms the performance of a 1.375 GHz radiometry system connected to an electromagnetically (EM) shielded microstrip log spiral antenna optimized for VUR detection. Phantom EM properties are characterized using a coaxial dielectric probe and network analyzer (NA). Power reflection and receive patterns of the antenna are measured in layered tissue phantom. Receiver spectral measurements are used to assess EM shielding provided by a metal cup surrounding the antenna. Radiometer and fiberoptic temperature data are recorded for varying volumes (10-30 mL) and temperaturesg (40-46°C) of the urine phantom at 35 mm depth surrounded by 36.5°C muscle phantom. Directional receive pattern with about 5% power spectral density at 35 mm target depth and better than -10 dB return loss from tissue load are measured for the antenna. Antenna measurements demonstrate no deterioration in power reception and effective EM shielding in the presence of the metal cup. Radiometry power measurements are in excellent agreement with the temperature of the kidney phantom. Laboratory testing of the radiometry system in temperature-controlled phantoms supports the feasibility of passive kidney thermometry for VUR detection.

  14. Comparing image search behaviour in the ARRS GoldMiner search engine and a clinical PACS/RIS.

    PubMed

    De-Arteaga, Maria; Eggel, Ivan; Do, Bao; Rubin, Daniel; Kahn, Charles E; Müller, Henning

    2015-08-01

    Information search has changed the way we manage knowledge and the ubiquity of information access has made search a frequent activity, whether via Internet search engines or increasingly via mobile devices. Medical information search is in this respect no different and much research has been devoted to analyzing the way in which physicians aim to access information. Medical image search is a much smaller domain but has gained much attention as it has different characteristics than search for text documents. While web search log files have been analysed many times to better understand user behaviour, the log files of hospital internal systems for search in a PACS/RIS (Picture Archival and Communication System, Radiology Information System) have rarely been analysed. Such a comparison between a hospital PACS/RIS search and a web system for searching images of the biomedical literature is the goal of this paper. Objectives are to identify similarities and differences in search behaviour of the two systems, which could then be used to optimize existing systems and build new search engines. Log files of the ARRS GoldMiner medical image search engine (freely accessible on the Internet) containing 222,005 queries, and log files of Stanford's internal PACS/RIS search called radTF containing 18,068 queries were analysed. Each query was preprocessed and all query terms were mapped to the RadLex (Radiology Lexicon) terminology, a comprehensive lexicon of radiology terms created and maintained by the Radiological Society of North America, so the semantic content in the queries and the links between terms could be analysed, and synonyms for the same concept could be detected. RadLex was mainly created for the use in radiology reports, to aid structured reporting and the preparation of educational material (Lanlotz, 2006) [1]. In standard medical vocabularies such as MeSH (Medical Subject Headings) and UMLS (Unified Medical Language System) specific terms of radiology are often underrepresented, therefore RadLex was considered to be the best option for this task. The results show a surprising similarity between the usage behaviour in the two systems, but several subtle differences can also be noted. The average number of terms per query is 2.21 for GoldMiner and 2.07 for radTF, the used axes of RadLex (anatomy, pathology, findings, …) have almost the same distribution with clinical findings being the most frequent and the anatomical entity the second; also, combinations of RadLex axes are extremely similar between the two systems. Differences include a longer length of the sessions in radTF than in GoldMiner (3.4 and 1.9 queries per session on average). Several frequent search terms overlap but some strong differences exist in the details. In radTF the term "normal" is frequent, whereas in GoldMiner it is not. This makes intuitive sense, as in the literature normal cases are rarely described whereas in clinical work the comparison with normal cases is often a first step. The general similarity in many points is likely due to the fact that users of the two systems are influenced by their daily behaviour in using standard web search engines and follow this behaviour in their professional search. This means that many results and insights gained from standard web search can likely be transferred to more specialized search systems. Still, specialized log files can be used to find out more on reformulations and detailed strategies of users to find the right content. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Low-Cost HIV-1 Diagnosis and Quantification in Dried Blood Spots by Real Time PCR

    PubMed Central

    Mehta, Nishaki; Trzmielina, Sonia; Nonyane, Bareng A. S.; Eliot, Melissa N.; Lin, Rongheng; Foulkes, Andrea S.; McNeal, Kristina; Ammann, Arthur; Eulalievyolo, Vindu; Sullivan, John L.; Luzuriaga, Katherine; Somasundaran, Mohan

    2009-01-01

    Background Rapid and cost-effective methods for HIV-1 diagnosis and viral load monitoring would greatly enhance the clinical management of HIV-1 infected adults and children in limited-resource settings. Recent recommendations to treat perinatally infected infants within the first year of life are feasible only if early diagnosis is routinely available. Dried blood spots (DBS) on filter paper are an easy and convenient way to collect and transport blood samples. A rapid and cost effective method to diagnose and quantify HIV-1 from DBS is urgently needed to facilitate early diagnosis of HIV-1 infection and monitoring of antiretroviral therapy. Methods and Findings We have developed a real-time LightCycler (rtLC) PCR assay to detect and quantify HIV-1 from DBS. HIV-1 RNA extracted from DBS was amplified in a one-step, single-tube system using primers specific for long-terminal repeat sequences that are conserved across all HIV-1 clades. SYBR Green dye was used to quantify PCR amplicons and HIV-1 RNA copy numbers were determined from a standard curve generated using serially diluted known copies of HIV-1 RNA. This assay detected samples across clades, has a dynamic range of 5 log10, and %CV <8% up to 4 log10 dilution. Plasma HIV-1 RNA copy numbers obtained using this method correlated well with the Roche Ultrasensitive (r = 0.91) and branched DNA (r = 0.89) assays. The lower limit of detection (95%) was estimated to be 136 copies. The rtLC DBS assay was 2.5 fold rapid as well as 40-fold cheaper when compared to commercial assays. Adaptation of the assay into other real-time systems demonstrated similar performance. Conclusions The accuracy, reliability, genotype inclusivity and affordability, along with the small volumes of blood required for the assay suggest that the rtLC DBS assay will be useful for early diagnosis and monitoring of pediatric HIV-1 infection in resource-limited settings. PMID:19503790

  16. Low-cost HIV-1 diagnosis and quantification in dried blood spots by real time PCR.

    PubMed

    Mehta, Nishaki; Trzmielina, Sonia; Nonyane, Bareng A S; Eliot, Melissa N; Lin, Rongheng; Foulkes, Andrea S; McNeal, Kristina; Ammann, Arthur; Eulalievyolo, Vindu; Sullivan, John L; Luzuriaga, Katherine; Somasundaran, Mohan

    2009-06-05

    Rapid and cost-effective methods for HIV-1 diagnosis and viral load monitoring would greatly enhance the clinical management of HIV-1 infected adults and children in limited-resource settings. Recent recommendations to treat perinatally infected infants within the first year of life are feasible only if early diagnosis is routinely available. Dried blood spots (DBS) on filter paper are an easy and convenient way to collect and transport blood samples. A rapid and cost effective method to diagnose and quantify HIV-1 from DBS is urgently needed to facilitate early diagnosis of HIV-1 infection and monitoring of antiretroviral therapy. We have developed a real-time LightCycler (rtLC) PCR assay to detect and quantify HIV-1 from DBS. HIV-1 RNA extracted from DBS was amplified in a one-step, single-tube system using primers specific for long-terminal repeat sequences that are conserved across all HIV-1 clades. SYBR Green dye was used to quantify PCR amplicons and HIV-1 RNA copy numbers were determined from a standard curve generated using serially diluted known copies of HIV-1 RNA. This assay detected samples across clades, has a dynamic range of 5 log(10), and %CV <8% up to 4 log(10) dilution. Plasma HIV-1 RNA copy numbers obtained using this method correlated well with the Roche Ultrasensitive (r = 0.91) and branched DNA (r = 0.89) assays. The lower limit of detection (95%) was estimated to be 136 copies. The rtLC DBS assay was 2.5 fold rapid as well as 40-fold cheaper when compared to commercial assays. Adaptation of the assay into other real-time systems demonstrated similar performance. The accuracy, reliability, genotype inclusivity and affordability, along with the small volumes of blood required for the assay suggest that the rtLC DBS assay will be useful for early diagnosis and monitoring of pediatric HIV-1 infection in resource-limited settings.

  17. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  18. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  19. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  20. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  1. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  2. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  3. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  4. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  5. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  6. A simplified hardwood log-sawing program for three-dimensional profile data

    Treesearch

    R. Edward Thomas

    2011-01-01

    Current laser scanning systems in sawmills collect low-resolution three-dimensional (3D) profiles of logs. However, these scanners are capable of much more. As a demonstration, the U.S. Forest Service, Forestry Sciences Laboratory in Princeton, WV, constructed a 3D laser log scanner using off -the-shelf industrial scanning components.

  7. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  8. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  9. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  10. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  11. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  12. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  13. Stochastic theory of log-periodic patterns

    NASA Astrophysics Data System (ADS)

    Canessa, Enrique

    2000-12-01

    We introduce an analytical model based on birth-death clustering processes to help in understanding the empirical log-periodic corrections to power law scaling and the finite-time singularity as reported in several domains including rupture, earthquakes, world population and financial systems. In our stochastic theory log-periodicities are a consequence of transient clusters induced by an entropy-like term that may reflect the amount of co-operative information carried by the state of a large system of different species. The clustering completion rates for the system are assumed to be given by a simple linear death process. The singularity at t0 is derived in terms of birth-death clustering coefficients.

  14. 3-Dimensional Root Cause Diagnosis via Co-analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Ziming; Lan, Zhiling; Yu, Li

    2012-01-01

    With the growth of system size and complexity, reliability has become a major concern for large-scale systems. Upon the occurrence of failure, system administrators typically trace the events in Reliability, Availability, and Serviceability (RAS) logs for root cause diagnosis. However, RAS log only contains limited diagnosis information. Moreover, the manual processing is time-consuming, error-prone, and not scalable. To address the problem, in this paper we present an automated root cause diagnosis mechanism for large-scale HPC systems. Our mechanism examines multiple logs to provide a 3-D fine-grained root cause analysis. Here, 3-D means that our analysis will pinpoint the failure layer,more » the time, and the location of the event that causes the problem. We evaluate our mechanism by means of real logs collected from a production IBM Blue Gene/P system at Oak Ridge National Laboratory. It successfully identifies failure layer information for 219 failures during 23-month period. Furthermore, it effectively identifies the triggering events with time and location information, even when the triggering events occur hundreds of hours before the resulting failures.« less

  15. Quaternion Based Thermal Condition Monitoring System

    NASA Astrophysics Data System (ADS)

    Wong, Wai Kit; Loo, Chu Kiong; Lim, Way Soong; Tan, Poi Ngee

    In this paper, we will propose a new and effective machine condition monitoring system using log-polar mapper, quaternion based thermal image correlator and max-product fuzzy neural network classifier. Two classification characteristics namely: peak to sidelobe ratio (PSR) and real to complex ratio of the discrete quaternion correlation output (p-value) are applied in the proposed machine condition monitoring system. Large PSR and p-value observe in a good match among correlation of the input thermal image with a particular reference image, while small PSR and p-value observe in a bad/not match among correlation of the input thermal image with a particular reference image. In simulation, we also discover that log-polar mapping actually help solving rotation and scaling invariant problems in quaternion based thermal image correlation. Beside that, log-polar mapping can have a two fold of data compression capability. Log-polar mapping can help smoother up the output correlation plane too, hence makes a better measurement way for PSR and p-values. Simulation results also show that the proposed system is an efficient machine condition monitoring system with accuracy more than 98%.

  16. Geophysical log database for the Floridan aquifer system and southeastern Coastal Plain aquifer system in Florida and parts of Georgia, Alabama, and South Carolina

    USGS Publications Warehouse

    Williams, Lester J.; Raines, Jessica E.; Lanning, Amanda E.

    2013-04-04

    A database of borehole geophysical logs and other types of data files were compiled as part of ongoing studies of water availability and assessment of brackish- and saline-water resources. The database contains 4,883 logs from 1,248 wells in Florida, Georgia, Alabama, South Carolina, and from a limited number of offshore wells of the eastern Gulf of Mexico and the Atlantic Ocean. The logs can be accessed through a download directory organized by state and county for onshore wells and in a single directory for the offshore wells. A flat file database is provided that lists the wells, their coordinates, and the file listings.

  17. High-resolution well-log derived dielectric properties of gas-hydrate-bearing sediments, Mount Elbert Gas Hydrate Stratigraphic Test Well, Alaska North Slope

    USGS Publications Warehouse

    Sun, Y.; Goldberg, D.; Collett, T.; Hunter, R.

    2011-01-01

    A dielectric logging tool, electromagnetic propagation tool (EPT), was deployed in 2007 in the BPXA-DOE-USGS Mount Elbert Gas Hydrate Stratigraphic Test Well (Mount Elbert Well), North Slope, Alaska. The measured dielectric properties in the Mount Elbert well, combined with density log measurements, result in a vertical high-resolution (cm-scale) estimate of gas hydrate saturation. Two hydrate-bearing sand reservoirs about 20 m thick were identified using the EPT log and exhibited gas-hydrate saturation estimates ranging from 45% to 85%. In hydrate-bearing zones where variation of hole size and oil-based mud invasion are minimal, EPT-based gas hydrate saturation estimates on average agree well with lower vertical resolution estimates from the nuclear magnetic resonance logs; however, saturation and porosity estimates based on EPT logs are not reliable in intervals with substantial variations in borehole diameter and oil-based invasion.EPT log interpretation reveals many thin-bedded layers at various depths, both above and below the thick continuous hydrate occurrences, which range from 30-cm to about 1-m thick. Such thin layers are not indicated in other well logs, or from the visual observation of core, with the exception of the image log recorded by the oil-base microimager. We also observe that EPT dielectric measurements can be used to accurately detect fine-scale changes in lithology and pore fluid properties of hydrate-bearing sediments where variation of hole size is minimal. EPT measurements may thus provide high-resolution in-situ hydrate saturation estimates for comparison and calibration with laboratory analysis. ?? 2010 Elsevier Ltd.

  18. Warm Absorbers in X-rays (WAX), a comprehensive high resolution grating spectral study of a sample of Seyfert galaxies

    NASA Astrophysics Data System (ADS)

    Laha, S.; Guainazzi, M.; Dewangan, G.; Chakravorty, S.; Kembhavi, A.

    2014-07-01

    We present results from a homogeneous analysis of the broadband 0.3-10 keV CCD resolution as well as of soft X-ray high-resolution grating spectra of a hard X-ray flux-limited sample of 26 Seyfert galaxies observed with XMM-Newton. We could put a strict lower limit on the detection fraction of 50%. We find a gap in the distribution of the ionisation parameter in the range 0.5

  19. The design and implementation of an automated system for logging clinical experiences using an anesthesia information management system.

    PubMed

    Simpao, Allan; Heitz, James W; McNulty, Stephen E; Chekemian, Beth; Brenn, B Randall; Epstein, Richard H

    2011-02-01

    Residents in anesthesia training programs throughout the world are required to document their clinical cases to help ensure that they receive adequate training. Current systems involve self-reporting, are subject to delayed updates and misreported data, and do not provide a practicable method of validation. Anesthesia information management systems (AIMS) are being used increasingly in training programs and are a logical source for verifiable documentation. We hypothesized that case logs generated automatically from an AIMS would be sufficiently accurate to replace the current manual process. We based our analysis on the data reporting requirements of the American College of Graduate Medical Education (ACGME). We conducted a systematic review of ACGME requirements and our AIMS record, and made modifications after identifying data element and attribution issues. We studied 2 methods (parsing of free text procedure descriptions and CPT4 procedure code mapping) to automatically determine ACGME case categories and generated AIMS-based case logs and compared these to assignments made by manual inspection of the anesthesia records. We also assessed under- and overreporting of cases entered manually by our residents into the ACGME website. The parsing and mapping methods assigned cases to a majority of the ACGME categories with accuracies of 95% and 97%, respectively, as compared with determinations made by 2 residents and 1 attending who manually reviewed all procedure descriptions. Comparison of AIMS-based case logs with reports from the ACGME Resident Case Log System website showed that >50% of residents either underreported or overreported their total case counts by at least 5%. The AIMS database is a source of contemporaneous documentation of resident experience that can be queried to generate valid, verifiable case logs. The extent of AIMS adoption by academic anesthesia departments should encourage accreditation organizations to support uploading of AIMS-based case log files to improve accuracy and to decrease the clerical burden on anesthesia residents.

  20. CMOS based image cytometry for detection of phytoplankton in ballast water.

    PubMed

    Pérez, J M; Jofre, M; Martínez, P; Yáñez, M A; Catalan, V; Parker, A; Veldhuis, M; Pruneri, V

    2017-02-01

    We introduce an image cytometer (I-CYT) for the analysis of phytoplankton in fresh and marine water environments. A linear quantification of cell numbers was observed covering several orders of magnitude using cultures of Tetraselmis and Nannochloropsis measured by autofluorescence in a laboratory environment. We assessed the functionality of the system outside the laboratory by phytoplankton quantification of samples taken from a marine water environment (Dutch Wadden Sea, The Netherlands) and a fresh water environment (Lake Ijssel, The Netherlands). The I-CYT was also employed to study the effects of two ballast water treatment systems (BWTS), based on chlorine electrolysis and UV sterilization, with the analysis including the vitality of the phytoplankton. For comparative study and benchmarking of the I-CYT, a standard flow cytometer was used. Our results prove a limit of detection (LOD) of 10 cells/ml with an accuracy between 0.7 and 0.5 log, and a correlation of 88.29% in quantification and 96.21% in vitality, with respect to the flow cytometry results.

  1. Internalization of Murine Norovirus 1 by Lactuca sativa during Irrigation ▿

    PubMed Central

    Wei, Jie; Jin, Yan; Sims, Tom; Kniel, Kalmia E.

    2011-01-01

    Romaine lettuce (Lactuca sativa) was grown hydroponically or in soil and challenged with murine norovirus 1 (MNV) under two conditions: one mimicking a severe one-time contamination event and another mimicking a lower level of contamination occurring over time. In each condition, lettuce was challenged with MNV delivered at the roots. In the first case, contamination occurred on day one with 5 × 108 reverse transcriptase quantitative PCR (RT-qPCR) U/ml MNV in nutrient buffer, and irrigation water was replaced with virus-free buffer every day for another 4 days. In the second case, contamination with 5 × 105 RT-qPCR U/ml MNV (freshly prepared) occurred every day for 5 days. Virus had a tendency to adsorb to soil particles, with a small portion suspended in nutrient buffer; e.g., ∼8 log RT-qPCR U/g MNV was detected in soil during 5 days of challenge with virus inoculums of 5 × 108 RT-qPCR U/ml at day one, but <6 log was found in nutrient buffer on days 3 and 5. For hydroponically grown lettuce, ∼3.4 log RT-qPCR U of viral RNA/50 mg of plant tissue was detected in some lettuce leaf samples after 5 days at high MNV inoculums, significantly higher than the internalized virus concentration (∼2.6 log) at low inoculums (P < 0.05). For lettuce grown in soil, approximately 2 log RT-qPCR U of viral RNA/50 mg of plant tissue was detected in lettuce with both high and low inoculums, showing no significant difference. For viral infectivity, infectious MNV was found in lettuce samples challenged with high virus inoculums grown hydroponically and in soil but not in lettuce grown with low virus inoculums. Lettuce grown hydroponically was further incubated in 99% and 70% relative humidities (RH) to evaluate plant transpiration relative to virus uptake. More lettuce samples were found positive for MNV at a significantly higher transpiration rate at 70% RH, indicating that transpiration might play an important role in virus internalization into L. sativa. PMID:21296944

  2. A Dynamically Configurable Log-based Distributed Security Event Detection Methodology using Simple Event Correlator

    DTIC Science & Technology

    2010-06-01

    shadow |\\/ etc\\/ passwd |cmd... \\.exe .*?)\\s.*\\s\\".*\\" desc=$0 action=shellcmd /home/user/sec -2.5.3/ common/syslogclient "... Synthetic : " "$2|$1...etc\\/ shadow |\\/ etc\\/ passwd |cmd... \\.exe .*?)\\s.*\\s\\".*\\" desc=$0 context =[ HYBRID_LOGGING] action=shellcmd /home/user/sec -2.5.3/ common...suspicious filenames type=Single continue=TakeNext ptype=RegExp pattern =(.*)\\s(.*)\\s.*(\\/ etc\\/ shadow |\\/ etc\\/ passwd |cmd\\.exe .*?)\\s... .*\\s(.*)\\s.*\\s

  3. Effects of Milk vs Dark Chocolate Consumption on Visual Acuity and Contrast Sensitivity Within 2 Hours: A Randomized Clinical Trial.

    PubMed

    Rabin, Jeff C; Karunathilake, Nirmani; Patrizi, Korey

    2018-04-26

    Consumption of dark chocolate can improve blood flow, mood, and cognition in the short term, but little is known about the possible effects of dark chocolate on visual performance. To compare the short-term effects of consumption of dark chocolate with those of milk chocolate on visual acuity and large- and small-letter contrast sensitivity. A randomized, single-masked crossover design was used to assess short-term visual performance after consumption of a dark or a milk chocolate bar. Thirty participants without pathologic eye disease each consumed dark and milk chocolate in separate sessions, and within-participant paired comparisons were used to assess outcomes. Testing was conducted at the Rosenberg School of Optometry from June 25 to August 15, 2017. Visual acuity (in logMAR units) and large- and small-letter contrast sensitivity (in the log of the inverse of the minimum detectable contrast [logCS units]) were measured 1.75 hours after consumption of dark and milk chocolate bars. Among the 30 participants (9 men and 21 women; mean [SD] age, 26 [5] years), small-letter contrast sensitivity was significantly higher after consumption of dark chocolate (mean [SE], 1.45 [0.04] logCS) vs milk chocolate (mean [SE], 1.30 [0.05] logCS; mean improvement, 0.15 logCS [95% CI, 0.08-0.22 logCS]; P < .001). Large-letter contrast sensitivity was slightly higher after consumption of dark chocolate (mean [SE], 2.05 [0.02] logCS) vs milk chocolate (mean [SE], 2.00 [0.02] logCS; mean improvement, 0.05 logCS [95% CI, 0.00-0.10 logCS]; P = .07). Visual acuity improved slightly after consumption of dark chocolate (mean [SE], -0.22 [0.01] logMAR; visual acuity, approximately 20/12) and milk chocolate (mean [SE], -0.18 [0.01] logMAR; visual acuity, approximately 20/15; mean improvement, 0.04 logMAR [95% CI, 0.02-0.06 logMAR]; P = .05). Composite scores combining results from all tests showed significant improvement after consumption of dark compared with milk chocolate (mean improvement, 0.20 log U [95% CI, 0.10-0.30 log U]; P < .001). Contrast sensitivity and visual acuity were significantly higher 2 hours after consumption of a dark chocolate bar compared with a milk chocolate bar, but the duration of these effects and their influence in real-world performance await further testing. clinicaltrials.gov Identifier: NCT03326934.

  4. Thiocyanate potentiates antimicrobial photodynamic therapy: In situ generation of the sulfur trioxide radical anion by singlet oxygen

    PubMed Central

    St Denis, Tyler G.; Vecchio, Daniela; Zadlo, Andrzej; Rineh, Ardeshir; Sadasivam, Magesh; Avci, Pinar; Huang, Liyi; Kozinska, Anna; Chandran, Rakkiyappan; Sarna, Tadeusz; Hamblin, Michael R.

    2013-01-01

    Antimicrobial photodynamic therapy (PDT) is used for the eradication of pathogenic microbial cells and involves the light excitation of dyes in the presence of O2, yielding reactive oxygen species including the hydroxyl radical (•OH) and singlet oxygen (1O2). In order to chemically enhance PDT by the formation of longer-lived radical species, we asked whether thiocyanate (SCN−) could potentiate the methylene blue (MB) and light-mediated killing of the gram-positive Staphylococcus aureus and the gram-negative Escherichia coli. SCN− enhanced PDT (10 μM MB, 5J/cm2 660 nm hv) killing in a concentration-dependent manner of S. aureus by 2.5 log10 to a maximum of 4.2 log10 at 10 mM (P < 0.001) and increased killing of E. coli by 3.6 log10 to a maximum of 5.0 log10 at 10 mM (P < 0.01). We determined that SCN− rapidly depleted O2 from an irradiated MB system, reacting exclusively with 1O2, without quenching the MB excited triplet state. SCN− reacted with 1O2, producing a sulfur trioxide radical anion (a sulfur-centered radical demonstrated by EPR spin trapping). We found that MB-PDT of SCN− in solution produced both sulfite and cyanide anions, and that addition of each of these salts separately enhanced MB-PDT killing of bacteria. We were unable to detect EPR signals of •OH, which, together with kinetic data, strongly suggests that MB, known to produce •OH and 1O2, may, under the conditions used, preferentially form 1O2. PMID:23969112

  5. Controlled iodine release from polyurethane sponges for water decontamination.

    PubMed

    Aviv, Oren; Laout, Natalia; Ratner, Stanislav; Harik, Oshrat; Kunduru, Konda Reddy; Domb, Abraham J

    2013-12-28

    Iodinated polyurethane (IPU) sponges were prepared by immersing sponges in aqueous/organic solutions of iodine or exposing sponges to iodine vapors. Iodine was readily adsorbed into the polymers up to 100% (w/w). The adsorption of iodine on the surface was characterized by XPS and SEM analyses. The iodine loaded IPU sponges were coated with ethylene vinyl acetate (EVA), in order to release iodine in a controlled rate for water decontamination combined with active carbon cartridge, which adsorbs the iodine residues after the microbial inactivation. The EVA coated IPU were incorporated in a water purifier and tested for iodine release to water and for microbial inactivation efficiency according to WQA certification program against P231/EPA for 250l, using 25l a day with flow rate of 6-8min/1l. The antimicrobial activity was also studied against Escherichia coli and MS2 phage. Bacterial results exceeded the minimal requirement for bacterial removal of 6log reduction throughout the entire lifespan. At any testing point, no bacteria was detected in the outlet achieving more than 7.1 to more than 8log reduction as calculated upon the inlet concentration. Virus surrogate, MS2, reduction results varied from 4.11log reduction under tap water, and 5.11log reduction under basic water (pH9) to 1.32 for acidic water (pH5). Controlled and stable iodine release was observed with the EVA coated IPU sponges and was effective in deactivating the bacteria and virus present in the contaminated water and thus, these iodinated PU systems could be used in water purification to provide safe drinking water. These sponges may find applications as disinfectants in medicine. © 2013.

  6. Effectiveness of liquid soap and hand sanitizer against Norwalk virus on contaminated hands.

    PubMed

    Liu, Pengbo; Yuen, Yvonne; Hsiao, Hui-Mien; Jaykus, Lee-Ann; Moe, Christine

    2010-01-01

    Disinfection is an essential measure for interrupting human norovirus (HuNoV) transmission, but it is difficult to evaluate the efficacy of disinfectants due to the absence of a practicable cell culture system for these viruses. The purpose of this study was to screen sodium hypochlorite and ethanol for efficacy against Norwalk virus (NV) and expand the studies to evaluate the efficacy of antibacterial liquid soap and alcohol-based hand sanitizer for the inactivation of NV on human finger pads. Samples were tested by real-time reverse transcription-quantitative PCR (RT-qPCR) both with and without a prior RNase treatment. In suspension assay, sodium hypochlorite concentrations of >or=160 ppm effectively eliminated RT-qPCR detection signal, while ethanol, regardless of concentration, was relatively ineffective, giving at most a 0.5 log(10) reduction in genomic copies of NV cDNA. Using the American Society for Testing and Materials (ASTM) standard finger pad method and a modification thereof (with rubbing), we observed the greatest reduction in genomic copies of NV cDNA with the antibacterial liquid soap treatment (0.67 to 1.20 log(10) reduction) and water rinse only (0.58 to 1.58 log(10) reduction). The alcohol-based hand sanitizer was relatively ineffective, reducing the genomic copies of NV cDNA by only 0.14 to 0.34 log(10) compared to baseline. Although the concentrations of genomic copies of NV cDNA were consistently lower on finger pad eluates pretreated with RNase compared to those without prior RNase treatment, these differences were not statistically significant. Despite the promise of alcohol-based sanitizers for the control of pathogen transmission, they may be relatively ineffective against the HuNoV, reinforcing the need to develop and evaluate new products against this important group of viruses.

  7. Brominated flame retardants in the indoor environment - Comparative study of indoor contamination from three countries.

    PubMed

    Venier, Marta; Audy, Ondřej; Vojta, Šimon; Bečanová, Jitka; Romanak, Kevin; Melymuk, Lisa; Krátká, Martina; Kukučka, Petr; Okeme, Joseph; Saini, Amandeep; Diamond, Miriam L; Klánová, Jana

    2016-09-01

    Concentrations of more than 20 brominated flame retardants (FRs), including polybrominated diphenyl ethers (PBDEs) and emerging FRs, were measured in air, dust and window wipes from 63 homes in Canada, the Czech Republic and the United States in the spring and summer of 2013. Among the PBDEs, the highest concentrations were generally BDE-209 in all three matrices, followed by Penta-BDEs. Among alternative FRs, EHTBB and BEHTBP were detected at the highest concentrations. DBDPE was also a major alternative FR detected in dust and air. Bromobenzenes were detected at lower levels than PBDEs and other alternative FRs; among the bromobenzenes, HBB and PBEB were the most abundant compounds. In general, FR levels were highest in the US and lowest in the Czech Republic - a geographic trend that reflects the flame retardants' market. No statistically significant differences were detected between bedroom and living room FR concentrations in the same house (n=10), suggesting that sources of FRs are widespread indoors and mixing between rooms. The concentrations of FRs in air, dust, and window film were significantly correlated, especially for PBDEs. We found a significant relationship between the concentrations in dust and window film and in the gas phase for FRs with log KOA values <14, suggesting that equilibrium was reached for these but not compounds with log KOA values >14. This hypothesis was confirmed by a large discrepancy between values predicted using a partitioning model and the measured values for FRs with log KOA values >14. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. 21 CFR 120.25 - Process verification for certain processors.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... accuracy, precision, and sensitivity in detecting E. coli. This method is designed to detect the presence... times: (i) Aseptically inoculate 10 mL of juice into 90 mL of Universal Preenrichment Broth (Difco) and... series of seven tests are positive for E. coli, the control measures to attain the 5-log reduction...

  9. 21 CFR 120.25 - Process verification for certain processors.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... accuracy, precision, and sensitivity in detecting E. coli. This method is designed to detect the presence... times: (i) Aseptically inoculate 10 mL of juice into 90 mL of Universal Preenrichment Broth (Difco) and... series of seven tests are positive for E. coli, the control measures to attain the 5-log reduction...

  10. Acoustic detection of Oryctes rhinoceros (Coleoptera: Scarabaeidae: Dynastinae) and Nasutitermes luzonicus (Isoptera: Termitidae) in palm trees of urban Guam

    USDA-ARS?s Scientific Manuscript database

    Adult and larval Oryctes rhinoceros (L) (Coleoptera: Scarabaeidae: Dynastinae) were acoustically detected in live and dead palm trees and logs in recently invaded areas of Guam, along with Nasutitermes (Isoptera: Termitidae), and other small, sound-producing invertebrates and invertebrates. The sou...

  11. Proliferation of Escherichia coli O157:H7 in Soil-Substitute and Hydroponic Microgreen Production Systems.

    PubMed

    Xiao, Zhenlei; Bauchan, Gary; Nichols-Russell, Lydia; Luo, Yaguang; Wang, Qin; Nou, Xiangwu

    2015-10-01

    Radish (Raphanus sativus var. longipinnatus) microgreens were produced from seeds inoculated with Escherichia coli O157:H7 by using peat moss-based soil-substitute and hydroponic production systems. E. coli populations on the edible and inedible parts of harvested microgreen plants (7 days postseeding) and in growth medium were examined. E. coli O157:H7 was shown to survive and proliferate significantly during microgreen growth in both production systems, with a higher level in the hydroponic production system. At the initial seed inoculation level of 3.7 log CFU/g, E. coli O157:H7 populations on the edible part of microgreen plants reached 2.3 and 2.1 log CFU/g (overhead irrigation and bottom irrigation, respectively) for microgreens from the soil-substitute production system and reached 5.7 log CFU/g for those hydroponically grown. At a higher initial inoculation of 5.6 log CFU/g seeds, the corresponding E. coli O157:H7 populations on the edible parts of microgreens grown in these production systems were 3.4, 3.6, and 5.3 log CFU/g, respectively. Examination of the spatial distribution of bacterial cells on different parts of microgreen plants showed that contaminated seeds led to systematic contamination of whole plants, including both edible and inedible parts, and seed coats remained the focal point of E. coli O157:H7 survival and growth throughout the period of microgreen production.

  12. Reference manual for data base on Nevada well logs

    USGS Publications Warehouse

    Bauer, E.M.; Cartier, K.D.

    1995-01-01

    The U.S. Geological Survey and Nevada Division of Water Resources are cooperatively using a data base for are cooperatively using a data base for managing well-log information for the State of Nevada. The Well-Log Data Base is part of an integrated system of computer data bases using the Ingres Relational Data-Base Management System, which allows efficient storage and access to water information from the State Engineer's office. The data base contains a main table, two ancillary tables, and nine lookup tables, as well as a menu-driven system for entering, updating, and reporting on the data. This reference guide outlines the general functions of the system and provides a brief description of data tables and data-entry screens.

  13. Near-infrared photometry of WISE J085510.74-071442.5

    NASA Astrophysics Data System (ADS)

    Zapatero Osorio, M. R.; Lodieu, N.; Béjar, V. J. S.; Martín, E. L.; Ivanov, V. D.; Bayo, A.; Boffin, H. M. J.; Mužić, K.; Minniti, D.; Beamín, J. C.

    2016-08-01

    Aims: We aim at obtaining near-infrared photometry and deriving the mass, age, temperature, and surface gravity of WISE J085510.74-071442.5 (J0855-0714), which is the coolest object beyond the solar system currently known. Methods: We used publicly available data from the archives of the Hubble Space Telescope (HST) and the Very Large Telescope (VLT) to determine the emission of this source at 1.153 μm (F110W) and 1.575 μm (CH4-off). J0855-0714 was detected at both wavelengths with a signal-to-noise ratio of ≈10 (F110W) and ≈4 (CH4-off) at the peak of the corresponding point-spread-functions. Results: This is the first detection of J0855-0714 in the H-band wavelengths. We measured 26.31 ± 0.10 and 23.22 ± 0.35 mag in F110W and CH4-off (Vega system). J0855-0714 remains unresolved in the HST images that have a spatial resolution of 0.22''. Companions at separations of 0.5 AU (similar mass and brightness) and at ~1 AU (≈1 mag fainter in the F110W filter) are discarded. By combining the new data with published photometry, including non-detections, we build the spectral energy distribution of J0855-0714 from 0.89 through 22.09 μm, and contrast it against current solar-metallicity models of planetary atmospheres. We determine that the best spectral fit yields a temperature of 225-250 K, a bolometric luminosity of log L/L⊙ = -8.57, and a high surface gravity of log g = 5.0 (cm s-2), which suggests an old age although a gravity this high is not fully compatible with evolutionary models. After comparing our data with the cooling theory for brown dwarfs and planets, we infer a mass in the interval 2-10 MJup for ages of 1-12 Gyr and high atmospheric gravities of log g ⪆ 3.5 (cm s-2). If it had the age of the Sun, J0855-0714 would be a ≈5-MJup free-floating planetary-mass object. Conclusions: J0855-0714 meets the mass values previously determined for free-floating planetary-mass objects discovered in star-forming regions and young stellar clusters. Based on extrapolations of the substellar mass functions of young clusters to the field, as many J0855-0714-like objects as M5-L2 stars may be expected to populate the solar neighborhood.

  14. Remote Monitoring of Soil Water Content, Temperature, and Heat Flow Using Low-Cost Cellular (3G) IoT Technology

    NASA Astrophysics Data System (ADS)

    Ham, J. M.

    2016-12-01

    New microprocessor boards, open-source sensors, and cloud infrastructure developed for the Internet of Things (IoT) can be used to create low-cost monitoring systems for environmental research. This project describes two applications in soil science and hydrology: 1) remote monitoring of the soil temperature regime near oil and gas operations to detect the thermal signature associated with the natural source zone degradation of hydrocarbon contaminants in the vadose zone, and 2) remote monitoring of soil water content near the surface as part of a global citizen science network. In both cases, prototype data collection systems were built around the cellular (2G/3G) "Electron" microcontroller (www.particle.io). This device allows connectivity to the cloud using a low-cost global SIM and data plan. The systems have cellular connectivity in over 100 countries and data can be logged to the cloud for storage. Users can view data real time over any internet connection or via their smart phone. For both projects, data logging, storage, and visualization was done using IoT services like Thingspeak (thingspeak.com). The soil thermal monitoring system was tested on experimental plots in Colorado USA to evaluate the accuracy and reliability of different temperature sensors and 3D printed housings. The soil water experiment included comparison opens-source capacitance-based sensors to commercial versions. Results demonstrate the power of leveraging IoT technology for field research.

  15. Computer analysis of digital well logs

    USGS Publications Warehouse

    Scott, James H.

    1984-01-01

    A comprehensive system of computer programs has been developed by the U.S. Geological Survey for analyzing digital well logs. The programs are operational on a minicomputer in a research well-logging truck, making it possible to analyze and replot the logs while at the field site. The minicomputer also serves as a controller of digitizers, counters, and recorders during acquisition of well logs. The analytical programs are coordinated with the data acquisition programs in a flexible system that allows the operator to make changes quickly and easily in program variables such as calibration coefficients, measurement units, and plotting scales. The programs are designed to analyze the following well-logging measurements: natural gamma-ray, neutron-neutron, dual-detector density with caliper, magnetic susceptibility, single-point resistance, self potential, resistivity (normal and Wenner configurations), induced polarization, temperature, sonic delta-t, and sonic amplitude. The computer programs are designed to make basic corrections for depth displacements, tool response characteristics, hole diameter, and borehole fluid effects (when applicable). Corrected well-log measurements are output to magnetic tape or plotter with measurement units transformed to petrophysical and chemical units of interest, such as grade of uranium mineralization in percent eU3O8, neutron porosity index in percent, and sonic velocity in kilometers per second.

  16. Analysis of Effects of Sensor Multithreading to Generate Local System Event Timelines

    DTIC Science & Technology

    2014-03-27

    works on logs highlights the importance of logs [17, 18]. The two aforementioned works both reference the same 2009 Data Breach Investigations Report...the data breaches report on, the logs contained evidence of events leading up to 82% of those data breaches . This means that preventing 82% of the data ...report states that of the data breaches reported on, the logs contained evidence of events leading up to 66% of those data breaches . • The 2010 DBIR

  17. Predicting Correctness of Problem Solving from Low-Level Log Data in Intelligent Tutoring Systems

    ERIC Educational Resources Information Center

    Cetintas, Suleyman; Si, Luo; Xin, Yan Ping; Hord, Casey

    2009-01-01

    This paper proposes a learning based method that can automatically determine how likely a student is to give a correct answer to a problem in an intelligent tutoring system. Only log files that record students' actions with the system are used to train the model, therefore the modeling process doesn't require expert knowledge for identifying…

  18. The Weak Link HP-41C hand-held calculator program

    Treesearch

    Ross A. Phillips; Penn A. Peters; Gary D. Falk

    1982-01-01

    The Weak Link hand-held calculator program (HP-41C) quickly analyzes a system for logging production and costs. The production equations model conventional chain saw, skidder, loader, and tandemaxle truck operations in eastern mountain areas. Production of each function of the logging system may be determined so that the system may be balanced for minimum cost. The...

  19. Performance of a logging truck with a central tire inflation system.

    Treesearch

    John A. Sturos; Douglas B. Brumm; Andrew Lehto

    1995-01-01

    Describes the performance of an 11-axle logging truck with a central tire inflation system. Results included reduced damages to roads, improved ride of the truck, improved drawbar pull, and reduced rolling resistance. Road construction costs were reduced 62%, primarily due to using 33% less gravel.

  20. Cost of wetland protection using cable logging systems

    Treesearch

    Chris B. LeDoux; John E. Baumgras

    1990-01-01

    Forest managers, loggers, land-use planners, and other decision makers need an understanding of estimating the cost of protecting wetlands using cable logging systems to harvest timber products. Results suggest that protection costs can range from $244.75 to $489.50 per acre depending on the degree of protection desired.

Top