Yan, J.-Q.; Cao, H. B.; McGuire, M. A.; ...
2013-06-10
The spin and orbital ordering in Dy₁₋ xTb xVO₃ (x=0 and 0.2) was studied by measuring x-ray powder diffraction, magnetization, specific heat, and neutron single-crystal diffraction. The results show that G-OO/C-AF and C-OO/G-AF phases coexist in Dy 0.8Tb 0.20VO 3 in the temperature range 2–60 K, and the volume fraction of each phase is temperature and field dependent. The ordering of Dy moments at T* = 12 K induces a transition from G-OO/C-AF to a C-OO/G-AF phase. Magnetic fields suppress the long-range order of Dy moments and thus the C-OO/G-AF phase below T*. The polarized moments induced at the Dymore » sublattice by external magnetic fields couple to the V 3d moments, and this coupling favors the G-OO/C-AF state. Also discussed is the effect of the Dy-V magnetic interaction and local structure distortion on the spin and orbital ordering in Dy₁₋ xTb xVO₃.« less
Neutron diffraction study of layered Ni dioxides: Ag2NiO2
NASA Astrophysics Data System (ADS)
Nozaki, Hiroshi; Sugiyama, Jun; Janoschek, Marc; Roessli, Bertrand; Pomjakushin, Vladimir; Keller, Lukas; Yoshida, Hiroyuki; Hiroi, Zenji
2008-03-01
In order to elucidate the antiferromagnetic (AF) nature of hexagonal Ag2NiO2 with TN = 56 K and to know the mechanism of the structural phase transition of TS~270 K, neutron powder diffraction patterns have been measured in the temperature range between 1.5 and 330 K. One magnetic Bragg peak indexed as \\frac {1}{3}~\\frac {1}{3}~0 is clearly observed below TN, confirming the formation of long-range AF order, reported by a muon-spin spectroscopy measurement. The weak intensity of the magnetic peak also suggests the two-dimensional nature of the AF order, but the spin structure is still unknown. In addition, the precise structural analysis of the data between 160 and 330 K shows that only the cH-axis length changes drastically at TS, which suggests the appearance of local Jahn-Teller distortion below TS.
Josephson-like spin current in junctions composed of antiferromagnets and ferromagnets
NASA Astrophysics Data System (ADS)
Moor, A.; Volkov, A. F.; Efetov, K. B.
2012-01-01
We study Josephson-like junctions formed by materials with antiferromagnetic (AF) order parameters. As an antiferromagnet, we consider a two-band material in which a spin density wave (SDW) arises. This could be Fe-based pnictides in the temperature interval Tc≤T≤TN, where Tc and TN are the critical temperatures for the superconducting and antiferromagnetic transitions, respectively. The spin current jSp in AF/F/AF junctions with a ballistic ferromagnetic layer and in tunnel AF/I/AF junctions is calculated. It depends on the angle between the magnetization vectors in the AF leads in the same way as the Josephson current depends on the phase difference of the superconducting order parameters in S/I/S tunnel junctions. It turns out that in AF/F/AF junctions, two components of the SDW order parameter are induced in the F layer. One of them oscillates in space with a short period ξF,b˜ℏv/H, while the other decays monotonously from the interfaces over a long distance of the order ξN,b=ℏv/2πT (where v, H, and T are the Fermi velocity, the exchange energy, and the temperature, respectively; the subindex “b” denotes the ballistic case). This is a clear analogy with the case of Josephson S/F/S junctions with a nonhomogeneous magnetization where short- and long-range condensate components are induced in the F layer. However, in contrast to the charge Josephson current in S/F/S junctions, the spin current in AF/F/AF junctions is not constant in space, but oscillates in the ballistic F layer. We also calculate the dependence of jSp on the deviation from the ideal nesting in the AF/I/AF junctions. The spin current is maximal in the insulating phase of the AF and decreases in the metallic phase. It turns to zero at the Neel point when the amplitude of the SDW is zero and changes sign for certain values of the detuning parameter.
Electronic self-organization in the single-layer manganite $$\\rm Pr_{1-x}Ca_{1+x}MnO4$$
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ye, Feng; Chi, Songxue; Fernandez-Baca, Jaime A
We use neutron scattering to investigate the doping evolution of the magnetic correlations in the single-layer manganitemore » $$\\rm Pr_{\\it 1-x}Ca_{\\it 1+x}MnO_4$$, away from the $x=0.5$ composition where the CE-type commensurate antiferromagnetic (AF) structure is stable. We find that short-range incommensurate spin correlations develop as the system is electron doped ($x<0.5$), which coexist with the CE-type AF order. This suggests that electron doping in this system induces an inhomogeneous electronic self-organization, where commensurate AF patches with $x=0.5$ are separated by electron-rich domain walls with short range magnetic correlations. This behavior is strikingly different than for the three-dimensional $$\\rm Pr_{\\it 1-x}Ca_{\\it x}MnO_3$$, where the long-range CE-type commensurate AF structure is stable over a wide range of electron or hole doping around $x=0.5$.« less
Structure and superconductivity in the ternary silicide CaAlSi
NASA Astrophysics Data System (ADS)
Ma, Rong; Huang, Gui-Qin; Liu, Mei
2007-06-01
Using the linear response-linearized Muffin-tin orbital (LR-LMTO) method, we study the electronic band structure, phonon spectra, electron-phonon coupling and superconductivity for c-axis ferromagnetic-like (F-like) and antiferromagnetic-like (AF-like) structures in ternary silicide CaAlSi. The following conclusions are drawn from our calculations. If Al and Si atoms are assumed to arrange along the c axis in an F-like long-range ordering (-Al-Al-Al-and-Si-Si-Si-), one could obtain the ultrasoft B1g phonon mode and thus very strong electron-phonon coupling in CaAlSi. However, the appearance of imaginary frequency phonon modes indicates the instability of such a structure. For Al and Si atoms arranging along the c axis in an AF-like long-range ordering (-Al-Si-Al-), the calculated electron-phonon coupling constant is equal to 0.8 and the logarithmically averaged frequency is 146.8 K. This calculated result can correctly yield the superconducting transition temperature of CaAlSi by the standard BCS theory in the moderate electron-phonon coupling strength. We propose that an AF-like superlattice model for Al (or Si) atoms along the c direction may mediate the inconsistency estimated from theory and experiment, and explain the anomalous superconductivity in CaAlSi.
NASA Astrophysics Data System (ADS)
Otsuka, Kei; Iikubo, Hideaki; Kogure, Takayuki; Takano, Yoshiki; Hiraki, Ko-ichi; Takahashi, Toshihiro; Cui, Hengbo; Kato, Reizo
2014-05-01
We performed 13C NMR measurements of a selectively 13C isotope-labeled single-crystal sample of a frustrated spin system, β'-Et2Me2P[Pd(dmit)2]2. A long-range antiferromagnetic (AF) ordering below 17 K was confirmed by the observation of NMR spectrum broadening and well split resonance lines at lower temperatures. NMR spectra in the AF state can be well explained by a two sublattice model. From the analysis of the angular dependence of the NMR spectrum, we clarified the magnetic structure in the AF state, where the easy and hard axes are the crystallographic c*- and b-axes, respectively, and the effective localized moments are quite small, ˜0.28 μB/dimer. This suggests a strong quantum fluctuation effect due to magnetic frustrations in a quasi-triangular spin-1/2 system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brinckmann, Jan; Woelfle, Peter
2004-11-01
The nearest-neighbor quantum antiferromagnetic (AF) Heisenberg model for spin-1/2 on a two-dimensional square lattice is studied in the auxiliary-fermion representation. Expressing spin operators by canonical fermionic particles requires a constraint on the fermion charge Q{sub i}=1 on each lattice site i, which is imposed approximately through the thermal average. The resulting interacting fermion system is first treated in mean-field theory (MFT), which yields an AF ordered ground state and spin waves in quantitative agreement with conventional spin-wave theory. At finite temperature a self-consistent approximation beyond mean field is required in order to fulfill the Mermin-Wagner theorem. We first discuss amore » fully self-consistent approximation, where fermions are renormalized due to fluctuations of their spin density, in close analogy to FLEX. While static properties like the correlation length, {xi}(T){proportional_to}exp(aJ/T), come out correctly, the dynamical response lacks the magnon-like peaks which would reflect the appearance of short-range order at low T. This drawback, which is caused by overdamping, is overcome in a 'minimal self-consistent approximation' (MSCA), which we derive from the equations of motion. The MSCA features dynamical scaling at small energy and temperature and is qualitatively correct both in the regime of order-parameter relaxation at long wavelengths {lambda}>{xi} and in the short-range-order regime at {lambda}<{xi}. We also discuss the impact of vertex corrections and the problem of pseudo-gap formation in the single-particle density of states due to long-range fluctuations. Finally we show that the (short-range) magnetic order in MFT and MSCA helps to fulfill the constraint on the local fermion occupancy.« less
Bunch, T Jared; May, Heidi T; Bair, Tami L; Crandall, Brian G; Cutler, Michael J; Day, John D; Jacobs, Victoria; Mallender, Charles; Osborn, Jeffrey S; Stevens, Scott M; Weiss, J Peter; Woller, Scott C
2016-07-11
The mechanisms behind the association of atrial fibrillation (AF) and dementia are unknown. We previously found a significantly increased risk of dementia in AF patients taking warfarin with a low percentage of time in therapeutic range. The purpose of this study was to determine the extent to which AF itself increases dementia risk, in addition to long-term anticoagulation exposure. A total of 10 537 patients anticoagulated with warfarin (target INR 2-3), managed by the Clinical Pharmacist Anticoagulation Service with no history of dementia were included. Warfarin indication was for AF (n=4460), thromboembolism (n=5868), and mechanical heart valve(s) (n=209). Patients in the latter 2 categories were included only if they had no prior history of AF. The primary outcome was dementia. Patients with AF were older and had higher rates of hypertension, diabetes, heart failure, and stroke. AF patients experienced higher rates of total dementia (5.8% versus 1.6%, P<0.0001), Alzheimer disease (2.8% versus 0.9%, P<0.0001), and vascular dementia (1.0% versus 0.2%, P<0.0001). A propensity analysis of 6030 patients was performed to account for baseline demographics differences. Long-term risk of dementia remained significant in AF patients compared with matched non-AF patients (total dementia: hazard ratio [HR]=2.42 [1.85-3.18], P<0.0001; Alzheimer: HR=2.04 [1.40-2.98], P<0.0001; senile: HR=2.46 [1.58-3.86], P<0.0001). Low percent therapeutic range compared with a higher percent therapeutic range was associated with dementia risk in both AF (26-50% versus >75%: HR=2.51, P=0.005) and non-AF groups (≤25% versus >75%: HR=3.92, P<0.0001). The presence of AF significantly increases risk of dementia, including Alzheimer's disease, compared with matched patients receiving warfarin anticoagulation for other reasons. Quality of anticoagulation management remains an important risk factor for dementia in all patients. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Multiferroic fluoride BaCoF4 Thin Films Grown Via Molecular Beam Epitaxy
NASA Astrophysics Data System (ADS)
Borisov, Pavel; Johnson, Trent; García-Castro, Camilo; Kc, Amit; Schrecongost, Dustin; Cen, Cheng; Romero, Aldo; Lederman, David
Multiferroic materials exhibit exciting physics related to the simultaneous presence of multiple long-range orders, in many cases consisting of antiferromagnetic (AF) and ferroelectric (FE) orderings. In order to provide a new, promising route for fluoride-based multiferroic material engineering, we grew multiferroic fluoride BaCoF4 in thin film form on Al2O3 (0001) substrates by molecular beam epitaxy. The films grow with the orthorhombic b-axis out-of-plane and with three in-plane structural twin domains along the polar c-axis directions. The FE ordering in thin films was verified by FE remanent hysteresis loops measurements at T = 14 K and by room temperature piezoresponse force microscopy (PFM). An AF behavior was found below Neel temperature TN ~ 80 K, which is in agreement with the bulk properties. At lower temperatures two additional magnetic phase transitions at 19 K and 41 K were found. First-principles calculations demonstrated that the growth strain applied to the bulk BaCoF4 indeed favors two canted spin orders, along the b- and a-axes, respectively, in addition to the main AF spin order along the c-axis. Supported by FAME (Contract 2013-MA-2382), WV Research Challenge Grant (HEPC.dsr.12.29), and DMREF-NSF 1434897.
Role of the d -d interaction in the antiferromagnetic phase of λ -(BEDT-STF ) 2FeCl4
NASA Astrophysics Data System (ADS)
Minamidate, Takaaki; Shindo, Hironori; Ihara, Yoshihiko; Kawamoto, Atsushi; Matsunaga, Noriaki; Nomura, Kazushige
2018-03-01
Magnetic susceptibility and proton nuclear magnetic resonance (1H-NMR ) measurements were performed for the quasi-two-dimensional π -d interacting system λ -(BEDT-STF ) 2FeCl4 at ambient pressure. Magnetic susceptibility arising from the 3 d spins of the FeCl4 anion show an anisotropy at low temperature and its temperature dependence for the external field parallel to the c axis is described as a broad peak structure at 8 K. A sharp peak in the temperature dependence of T1-1 associated with the antiferromagnetic (AF) transition is observed at TAF=16 K, together with the drastic splitting of the NMR spectrum below TAF. The relation between the static susceptibility and the splitting of the NMR shift suggests the existence of the relatively strong d -d AF interaction. These results can be explained by the model considering the AF-coupled d -spin system in the AF long-range-ordered π -spin system. We find that the AF phases in λ -type salts can be universally explained by this model.
NASA Astrophysics Data System (ADS)
Kim, SungKun; Lee, Hunpyo
2017-06-01
Via a dynamical cluster approximation with N c = 4 in combination with a semiclassical approximation (DCA+SCA), we study the doped two-dimensional Hubbard model. We obtain a plaquette antiferromagnetic (AF) Mott insulator, a plaquette AF ordered metal, a pseudogap (or d-wave superconductor) and a paramagnetic metal by tuning the doping concentration. These features are similar to the behaviors observed in copper-oxide superconductors and are in qualitative agreement with the results calculated by the cluster dynamical mean field theory with the continuous-time quantum Monte Carlo (CDMFT+CTQMC) approach. The results of our DCA+SCA differ from those of the CDMFT+CTQMC approach in that the d-wave superconducting order parameters are shown even in the high doped region, unlike the results of the CDMFT+CTQMC approach. We think that the strong plaquette AF orderings in the dynamical cluster approximation (DCA) with N c = 4 suppress superconducting states with increasing doping up to strongly doped region, because frozen dynamical fluctuations in a semiclassical approximation (SCA) approach are unable to destroy those orderings. Our calculation with short-range spatial fluctuations is initial research, because the SCA can manage long-range spatial fluctuations in feasible computational times beyond the CDMFT+CTQMC tool. We believe that our future DCA+SCA calculations should supply information on the fully momentum-resolved physical properties, which could be compared with the results measured by angle-resolved photoemission spectroscopy experiments.
Antiferromagnetic Chern Insulators in Noncentrosymmetric Systems
NASA Astrophysics Data System (ADS)
Jiang, Kun; Zhou, Sen; Dai, Xi; Wang, Ziqiang
2018-04-01
We investigate a new class of topological antiferromagnetic (AF) Chern insulators driven by electronic interactions in two-dimensional systems without inversion symmetry. Despite the absence of a net magnetization, AF Chern insulators (AFCI) possess a nonzero Chern number C and exhibit the quantum anomalous Hall effect (QAHE). Their existence is guaranteed by the bifurcation of the boundary line of Weyl points between a quantum spin Hall insulator and a topologically trivial phase with the emergence of AF long-range order. As a concrete example, we study the phase structure of the honeycomb lattice Kane-Mele model as a function of the inversion-breaking ionic potential and the Hubbard interaction. We find an easy z axis C =1 AFCI phase and a spin-flop transition to a topologically trivial x y plane collinear antiferromagnet. We propose experimental realizations of the AFCI and QAHE in correlated electron materials and cold atom systems.
Ultracold Realization of AntiFerromagenteic Order
NASA Astrophysics Data System (ADS)
Shrestha, Uttam
2011-03-01
We investigate numerically the experimental feasibility of observing the antiferromagnetic (AF) order in the bosonic mixtures of rubidium (87 Rb) and potassium (41 K) in a two-dimensional optical lattice with external trapping potential. Within the mean-field approximation we have found the ground states which, for a specific range of parameters such as inter-species interactions and lattice height, interpolate from phase separation to the AF order. For the moderate lattice heights the coexistence of the Mott and AF phase is possible for rubidium atoms while the potassium atoms remain superfluid with overlapped AF phase. In our view there has not been any study on AF order in two-component systems when one component remains in the superfluid phase while the other is in the Mott phase. Therefore, this observation may provide a novel regime for studying quantum magnetism in ultracold systems. This work was supported by the EU Contract EU STREP NAMEQUAM.
Spin-isotropic continuum of spin excitations in antiferromagnetically ordered Fe1.07Te
NASA Astrophysics Data System (ADS)
Song, Yu; Lu, Xingye; Regnault, L.-P.; Su, Yixi; Lai, Hsin-Hua; Hu, Wen-Jun; Si, Qimiao; Dai, Pengcheng
2018-02-01
Unconventional superconductivity typically emerges in the presence of quasidegenerate ground states, and the associated intense fluctuations are likely responsible for generating the superconducting state. Here we use polarized neutron scattering to study the spin space anisotropy of spin excitations in Fe1.07Te exhibiting bicollinear antiferromagnetic (AF) order, the parent compound of FeTe1 -xSex superconductors. We confirm that the low-energy spin excitations are transverse spin waves, consistent with a local-moment origin of the bicollinear AF order. While the ordered moments lie in the a b plane in Fe1.07Te , it takes less energy for them to fluctuate out of plane, similar to BaFe2As2 and NaFeAs. At energies above E ≳20 meV, we find magnetic scattering to be dominated by an isotropic continuum that persists up to at least 50 meV. Although the isotropic spin excitations cannot be ascribed to spin waves from a long-range-ordered local-moment antiferromagnet, the continuum can result from the bicollinear magnetic order ground state of Fe1.07Te being quasidegenerate with plaquette magnetic order.
Laser long-range remote-sensing program experimental results
NASA Astrophysics Data System (ADS)
Highland, Ronald G.; Shilko, Michael L.; Fox, Marsha J.; Gonglewski, John D.; Czyzak, Stanley R.; Dowling, James A.; Kelly, Brian; Pierrottet, Diego F.; Ruffatto, Donald; Loando, Sharon; Matsuura, Chris; Senft, Daniel C.; Finkner, Lyle; Rae, Joe; Gallegos, Joe
1995-12-01
A laser long range remote sensing (LRS) program is being conducted by the United States Air Force Phillips Laboratory (AF/PL). As part of this program, AF/PL is testing the feasibility of developing a long path CO(subscript 2) laser-based DIAL system for remote sensing. In support of this program, the AF/PL has recently completed an experimental series using a 21 km slant- range path (3.05 km ASL transceiver height to 0.067 km ASL target height) at its Phillips Laboratory Air Force Maui Optical Station (AMOS) facility located on Maui, Hawaii. The dial system uses a 3-joule, (superscript 13)C isotope laser coupled into a 0.6 m diameter telescope. The atmospheric optical characterization incorporates information from an infrared scintillometer co-aligned to the laser path, atmospheric profiles from weather balloons launched from the target site, and meteorological data from ground stations at AMOS and the target site. In this paper, we report a description of the experiment configuration, a summary of the results, a summary of the atmospheric conditions and their implications to the LRS program. The capability of such a system for long-range, low-angle, slant-path remote sensing is discussed. System performance issues relating to both coherent and incoherent detection methods, atmospheric limitations, as well as, the development of advanced models to predict performance of long range scenarios are presented.
Low strain, long life creep fatigue of AF2-1DA and INCO 718
NASA Technical Reports Server (NTRS)
Thakker, A. B.; Cowles, B. A.
1983-01-01
Two aircraft turbine disk alloys, GATORIZED AF2-DA and INCO 718 were evaluated for their low strain long life creep-fatigue behavior. Static (tensile and creep rupture) and cyclic properties of both alloys were characterized. The cntrolled strain LCF tests were conducted at 760 C (1400 F) and 649 C (1200 F) for AF2-1DA and INCO 718, respectively. Hold times were varied for tensile, compressive and tensile/compressive strain dwell (relaxation) tests. Stress (creep) hold behavior of AF2-1DA was also evaluated. Generally, INCO 718 exhibited more pronounced reduction in cyclic life due to hold than AF2-1DA. The percent reduction in life for both alloys for strain dwell tests was greater at low strain ranges (longer life regime). Changing hold time from 0 to 0.5, 2.0 and 15.0 min. resulted in corresponding reductions in life. The continuous cycle and cyclic/dwell initiation failure mechanism was predominantly transgranular for AF2-1DA and intergranular for INCO 718.
Liang, Jackson J; Elafros, Melissa A; Muser, Daniele; Pathak, Rajeev K; Santangeli, Pasquale; Zado, Erica S; Frankel, David S; Supple, Gregory E; Schaller, Robert D; Deo, Rajat; Garcia, Fermin C; Lin, David; Hutchinson, Mathew D; Riley, Michael P; Callans, David J; Marchlinski, Francis E; Dixit, Sanjay
2016-11-01
Transformation from persistent to paroxysmal atrial fibrillation (AF) after ablation suggests modification of the underlying substrate. We examined the nature of initial arrhythmia recurrence in patients with nonparoxysmal AF undergoing antral pulmonary vein isolation and nonpulmonary vein trigger ablation and correlated recurrence type with long-term ablation efficacy after the last procedure. Three hundred and seventeen consecutive patients with persistent (n=200) and long-standing persistent (n=117) AF undergoing first ablation were included. AF recurrence was defined as early (≤6 weeks) or late (>6 weeks after ablation) and paroxysmal (either spontaneous conversion or treated with cardioversion ≤7 days) or persistent (lasting >7 days). During median follow-up of 29.8 (interquartile range: 14.8-49.9) months, 221 patients had ≥1 recurrence. Initial recurrence was paroxysmal in 169 patients (76%) and persistent in 52 patients (24%). Patients experiencing paroxysmal (versus persistent) initial recurrence were more likely to achieve long-term freedom off antiarrhythmic drugs (hazard ratio, 2.2; 95% confidence interval, 1.5-3.2; P<0.0001), freedom on/off antiarrhythmic drugs (hazard ratio, 2.5; 95% confidence interval, 1.6-3.8; P<0.0001), and arrhythmia control (hazard ratio, 5.2; 95% confidence interval, 2.9-9.2; P<0.0001) after last ablation. In patients with persistent and long-standing persistent AF, limited ablation targeting pulmonary veins and documented nonpulmonary vein triggers improves the maintenance of sinus rhythm and reverses disease progression. Transformation to paroxysmal AF after initial ablation may be a step toward long-term freedom from recurrent arrhythmia. © 2016 American Heart Association, Inc.
Geometric Magnetic Frustration in Li3Mg2OsO6 Studied with Muon Spin Relaxation
NASA Astrophysics Data System (ADS)
Carlo, J. P.; Derakhshan, S.; Greedan, J. E.
Geometric frustration manifests when the spatial arrangement of ions inhibits magnetic order. Typically associated with antiferromagnetically (AF)-correlated moments on triangular or tetrahedral lattices, frustration occurs in a variety of structures and systems, resulting in rich phase diagrams and exotic ground states. As a window to exotic physics revealed by the cancellation of normally dominant interactions, the research community has taken great interest in frustrated systems. One family of recent interest are the rock-salt ordered oxides A5BO6, in which the B sites are occupied by magnetic ions comprising a network of interlocked tetrahedra, and nonmagnetic ions on the A sites control the B oxidation state through charge neutrality. Here we will discuss studies of Li3Mg2OsO6 using muon spin relaxation (μSR), a highly sensitive local probe of magnetism. Previous studies of this family included Li5OsO6, which exhibits AF order below 50K with minimal evidence for frustration, and Li4MgReO6, which exhibits glassy magnetism. Li3Mg2RuO6, meanwhile, exhibits long-range AF, with the ordering temperature suppressed by frustration. But its isoelectronic twin, Li3Mg2OsO6 (5d3 vs. 4d3) exhibits very different behavior, revealed by μSR to be a glassy ground state below 12K. Understanding why such similar systems exhibit diverse ground-state behavior is key to understanding the nature of geometric magnetic frustration. Financial support from the Research Corporation for Science Advancement.
Sentence processing and verbal working memory in a white-matter-disconnection patient.
Meyer, Lars; Cunitz, Katrin; Obleser, Jonas; Friederici, Angela D
2014-08-01
The Arcuate Fasciculus/Superior Longitudinal Fasciculus (AF/SLF) is the white-matter bundle that connects posterior superior temporal and inferior frontal cortex. Its causal functional role in sentence processing and verbal working memory is currently under debate. While impairments of sentence processing and verbal working memory often co-occur in patients suffering from AF/SLF damage, it is unclear whether these impairments result from shared white-matter damage to the verbal-working-memory network. The present study sought to specify the behavioral consequences of focal AF/SLF damage for sentence processing and verbal working memory, which were assessed in a single patient suffering from a cleft-like lesion spanning the deep left superior temporal gyrus, sparing most surrounding gray matter. While tractography suggests that the ventral fronto-temporal white-matter bundle is intact in this patient, the AF/SLF was not visible to tractography. In line with the hypothesis that the AF/SLF is causally involved in sentence processing, the patient׳s performance was selectively impaired on sentences that jointly involve both complex word orders and long word-storage intervals. However, the patient was unimpaired on sentences that only involved long word-storage intervals without involving complex word orders. On the contrary, the patient performed generally worse than a control group across standard verbal-working-memory tests. We conclude that the AF/SLF not only plays a causal role in sentence processing, linking regions of the left dorsal inferior frontal gyrus to the temporo-parietal region, but moreover plays a crucial role in verbal working memory, linking regions of the left ventral inferior frontal gyrus to the left temporo-parietal region. Together, the specific sentence-processing impairment and the more general verbal-working-memory impairment may imply that the AF/SLF subserves both sentence processing and verbal working memory, possibly pointing to the AF and SLF respectively supporting each. Copyright © 2014 Elsevier Ltd. All rights reserved.
Predictors of Long-term Success After Concomitant Surgical Ablation for Atrial Fibrillation.
Pecha, Simon; Ghandili, Susanne; Hakmi, Samer; Willems, Stephan; Reichenspurner, Hermann; Wagner, Florian Mathias
2017-01-01
According to guidelines, atrial fibrillation (AF) ablation success should be measured by 24-hour Holter electrocardiogram (ECG). However, information on long-term success, especially obtained by 24-hour Holter ECG, is rare. We therefore analyzed rhythm course and long-term outcomes of our patients undergoing concomitant surgical AF ablation. Between January 2003 and April 2011, 486 patients underwent concomitant surgical AF ablation in our institution. Patients with 24-hour Holter ECG rhythm status available between 5 and 10 years postoperatively were included in this retrospective data analysis (n = 155). Ablation lesions were limited to either a pulmonary vein isolation (n = 31, 20%), a more complex left atrial lesion set (n = 89, 57%), or biatrial lesions (n = 35, 23%). Primary end point of the study was freedom from AF during long-term follow-up. Mean patient age was 68.1 ± 8.4 years; 57.4% were male. Mean follow-up time was 5.9 years. Surgical AF ablation provided freedom from AF rate of 56.6% during long-term follow-up, with significantly better results in patients with paroxysmal than in those with persistent AF (67.2% vs 51.8% P = 0.03). A stable rhythm course was observed during follow-up, without statistically significant differences between 12 months and latest follow-up (63.2% vs 56.6%; P = 0.25). In multivariate analysis, preoperative paroxysmal AF, duration of AF, and left atrial diameter were predictors of long-term ablation success. Surgical AF ablation provided freedom from AF rate of 56.6% during long-term follow-up. Statistically significant predictors of ablation success at latest follow-up were preoperative paroxysmal AF, duration of AF, and a preoperative smaller left atrial diameter. Copyright © 2017. Published by Elsevier Inc.
Investigating relationships between left atrial volume, symmetry, and sphericity
NASA Astrophysics Data System (ADS)
Menon, Prahlad G.; Nedios, Sotiris; Hindricks, Gerhard; Bollmann, Andreas
2016-03-01
Catheter ablation is a safe and effective therapy for drug-refractory patients symptomatic of atrial fibrillation (AF), with up to 80% of patients experiencing long-term arrhythmia-free survival. However, up to 20-40% of patients require more than one procedure in order to become arrhythmia-free. Therefore, appropriate patient selection is paramount to the effective implementation and long-term success of ablation therapy for patients with atrial fibrillation (AF). In this study, as a precursor to evaluating clinical significance of specific LA shape metrics as pre-procedural predictors of AF recurrence following ablative pulmonary vein isolation therapy, we report on a computational geometric analysis in a pilot cohort evaluating relationships between various patient-specific metrics of LA shape which might have such predictive value. This study specifically is focused on establishing the relationship between LA volume and sphericity, using a novel methodology for computing atrial sphericity based on regional shape.
NASA Astrophysics Data System (ADS)
Ryzhov, V. A.; Lashkul, A. V.; Matveev, V. V.; Molkanov, P. L.; Kurbakov, A. I.; Kiselev, I. A.; Lisunov, K. G.; Galimov, D.; Lähderanta, E.
2018-01-01
Two porous glassy carbon-based samples doped with Au and Co were investigated. The magnetization study as well as measurements of the nonlinear longitudinal response to a weak ac field (NLR) and electron magnetic resonance give evidences for a presence of magnetic nanoparticles (MNPs) embedded in paramagnetic/ferromagnetic matrix respectively, both samples being in magnetically phase-separated state at temperatures above 300 K. Matrix, forming by paramagnetic centers located in matrix outside the MNPs, reveals exchange interactions providing its ferromagnetic (FM) ordering below TC ≈ 210 K in Au-doped sample and well above 350 K in Co-doped one. For the former, NLR data suggest a percolation character of the matrix long-range FM order, which is mainly caused by a porous amorphous sample structure. Temperature dependence of the magnetization in the Au-doped sample evidences presence of antiferromagnetic (AF) interactions of MNPs with surrounding matrix centers. At magnetic ordering below TC these interactions promote origination of "domains" involving matrix fragment and surrounding MNPs with near opposite orientation of their moments that decreases the magnetostatic energy. On further cooling, the domains exhibit AF ordering below Tcr ∼ 140 K < TC, resulting in formation of a peculiar "ferrimagnet". The porous amorphous structure leads to absence of translational and other symmetry features through the samples that allows canted ordering of magnetic moments in domains and in whole sample providing "canted ferrimagnetism". At low temperatures Ttr ∼ 3 K, "order-oder" transition, evidencing the non-Heisenberg character of this magnetic material, occurs from ordering like "canted ferrimagnet" to FM alignment, which is stimulated by external magnetic field. The data for Co-doped sample imply the similar evolution of magnetic state but at higher temperatures above 350 K. This state exhibits more homogeneous arrangement of the FM nanoparticles and the FM matrix. Order-order transition occurs in it at higher Ttr ∼ 10-15 K as well and followed by formation of long-range FM ordering found earlier by neutron diffraction. Doping of carbon-based nanomaterials by magnetic metals provides advantages for their possible practical applications as Co-doped sample with higher TC (>350 K) and larger remanent magnetization evidences.
Huang, Henry D; Waks, Jonathan W; Steinhaus, Daniel A; Zimetbaum, Peter
2016-07-01
Dofetilide is a class III antiarrhythmic drug approved for the treatment of atrial fibrillation (AF). Dofetilide-induced corrected QT (QTc) interval prolongation is a surrogate for the degree of drug effect, but the relationships between drug-induced QTc interval prolongation, pharmacological cardioversion (PCV), and freedom from recurrent AF are unclear. The purpose of this study was to assess associations between QTc interval change during dofetilide initiation and PCV and long-term AF recurrence. We performed retrospective analyses of a prospective cohort of patients with AF admitted for dofetilide initiation between 2001 and 2014. Clinical characteristics and electrocardiographic variables were assessed. We evaluated outcomes of successful PCV in patients with persistent AF and time to recurrence of AF in patients with paroxysmal and persistent AF. During the study, 243 patients with persistent AF and 176 patients with paroxysmal AF initiated dofetilide. PCV occurred in 93/243 (41.7%) patients with persistent AF. After multivariable adjustment, QTc interval change was associated with PCV (adjusted odds ratio 1.21; P = .003 per 10-ms QTc increase). Inhospital QTc interval change was associated with long-term freedom from AF in patients with persistent AF (adjusted hazard ratio 0.92; P = .011 at 4 years per 10-ms QTc increase), but not in patients with paroxysmal AF. In patients with persistent AF, PCV was also associated with long-term freedom from recurrent AF (adjusted hazard ratio 0.62; P = .009 at 4 years). The magnitude of QTc interval prolongation during dofetilide initiation is an independent predictor of successful PCV and long-term freedom from arrhythmia in patients with persistent AF. QTc interval change had no association with AF recurrence in patients with paroxysmal AF, suggesting that different mechanisms of arrhythmogenesis may be operant in different AF types. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Abram, M; Zegrodnik, M; Spałek, J
2017-09-13
In the first part of the paper, we study the stability of antiferromagnetic (AF), charge density wave (CDW), and superconducting (SC) states within the t-J-U-V model of strongly correlated electrons by using the statistically consistent Gutzwiller approximation (SGA). We concentrate on the role of the intersite Coulomb interaction term V in stabilizing the CDW phase. In particular, we show that the charge ordering appears only above a critical value of V in a limited hole-doping range δ. The effect of the V term on SC and AF phases is that a strong interaction suppresses SC, whereas the AF order is not significantly influenced by its presence. In the second part, separate calculations for the case of a pure SC phase have been carried out within an extended approach (the diagrammatic expansion for the Gutzwiller wave function, DE-GWF) in order to analyze the influence of the intersite Coulomb repulsion on the SC phase with the higher-order corrections included beyond the SGA method. The upper concentration for the SC disappearance decreases with increasing V, bringing the results closer to experiment. In appendices A and B we discuss the ambiguity connected with the choice of the Gutzwiller renormalization factors within the renormalized mean filed theory when either AF or CDW orders are considered. At the end, we overview briefly the possible extensions of the current models to put descriptions of the SC, AF, and CDW states on equal footing.
The evolution from long-range magnetic order to spin-glass behaviour in PrAu2(Si1- xGex)2
NASA Astrophysics Data System (ADS)
Krimmel, A.; Hemberger, J.; Kegler, C.; Nicklas, M.; Engelmayer, A.; Knebel, G.; Fritsch, V.; Reehuis, M.; Brando, M.; Loidl, A.
1999-09-01
We have studied the magnetic behaviour of PrAu2(Si1-xGex)2 by means of magnetic susceptibility, resistivity, and heat capacity measurements, and x-ray and neutron powder diffraction. All compounds are isostructural and crystallize in the well known ThCr2Si2-type structure. PrAu2Si2 shows the characteristic features of a canonical spin glass with a freezing temperature of TF = 3 K. Completely unexpectedly, on introducing/increasing the atomic disorder by alloying with Ge, the spin-glass transition is suppressed as is first evident from a slight decrease of the freezing temperature TF up to x = 0.10. Long-range magnetic order sets in for xicons/Journals/Common/ge" ALT="ge" ALIGN="TOP"/>0.12. Within the range 0.15icons/Journals/Common/le" ALT="le" ALIGN="TOP"/> xicons/Journals/Common/le" ALT="le" ALIGN="TOP"/>1, all compounds show the same simple AF-I-type antiferromagnetic structure with a monotonic increase of both the Néel temperature and the ordered magnetic moment for increasing Ge concentration. The magnetic phase diagram of PrAu2(Si1-xGex)2 is explained by the presence of weak disorder at a constant level at the Au sites. Clear indications of crystal-field effects have been observed.
Hartman, Esther; Smith, Joanne; Houwen, Suzanne; Visscher, Chris
2017-05-01
Children with intellectual disabilities (ID) or borderline intellectual disabilities (BIF) often demonstrate impairments in executive functioning (EF). Studies in typically developing children show that aerobic fitness (AF) is positively related with EF. Skill-related physical fitness (SF) might, however, be a stronger predictor of EF than AF, as cognitive challenges are inherent in application of these skills. In this study, AF and SF were examined simultaneously in relationship with domains of EF in children with ID or BIF. Seventy-three children (age range 8-11; 51 boys) with ID (IQ range 56-79) or BIF (IQ range 71-79) were measured annually over a period of 4 years on AF (20-m endurance shuttle run test) and SF (plate tapping and 10×5m run). EF was measured with the Stroop Color-Word test (inhibition), Trailmaking and Fluency test (cognitive flexibility), Self-ordered pointing task (working memory) and the Tower of London (planning). Multilevel models showed that SF was significantly associated with inhibition and both measures of cognitive flexibility, but in the same models no significant associations between AF and EF were found. In addition, age was significantly related to working memory and cognitive flexibility, favouring the older children. In children with ID or BIF, SF is of greater importance than AF in relationship with core domains of EF. Copyright © 2017 Elsevier Ltd. All rights reserved.
Winkle, Roger A; Mead, R Hardwin; Engel, Gregory; Kong, Melissa H; Fleming, William; Salcedo, Jonathan; Patrawala, Rob A
2017-06-01
There is an association between obesity and atrial fibrillation (AF). The impact of obesity on AF ablation procedures is unclear. The purpose of this study was to evaluate the influence of body mass index (BMI) on patient characteristics, long-term ablation outcomes, and procedural complications. We evaluated 2715 patients undergoing 3742 AF ablation procedures. BMI was ≥30 kg/m 2 in 1058 (39%) and ≥40 kg/m 2 in 129 (4.8%). Patients were grouped by BMI ranges (<25, 25-<30, 30-<35, 35-<40, and ≥40 kg/m 2 ). As BMI increased from <25 to ≥40 kg/m 2 , age decreased from 65.3 ± 11.2 to 61.2 ± 9.2 years (P < .001), left atrial size increased from 3.91 ± 0.68 to 4.72 ± 0.62 cm (P < .005), and CHADS 2 scores increased from 1.24 ± 1.10 to 1.62 ± 1.09 (P < .001). As BMI increased, paroxysmal AF decreased from 48.0% to 16.3% (P < .0001) and there was an increase in dilated cardiomyopathy (from 7.6% to 12.4%; P < .0001), hypertension (from 41.0% to 72.9%; P < .0001), diabetes (from 4.3% to 23.3%; P < .0001), and sleep apnea (from 7.0% to 46.9%; P < .0001). For the entire cohort, for BMI ≥35 kg/m 2 the 5-year ablation freedom from AF decreased from 67%-72% to 57% (P = .036). For paroxysmal AF, when BMI was ≥40 kg/m 2 ablation success decreased from 79%-82% to 60% (P = .064), and for persistent AF, when BMI was ≥35 kg/m 2 ablation success decreased from 64%-70% to 52%-57% (P = .021). For long-standing AF, there was no impact of BMI on outcomes (P = .624). In multivariate analysis, BMI ≥35 kg/m 2 predicted worse outcomes (P = .036). Higher BMI did not impact major complication rates (P = .336). However, when BMI was ≥40 kg/m 2 , minor (from 2.1% to 4.4%; P = .035) and total (from 3.5% to 6.7%; P = .023) complications increased. In patients undergoing AF ablation, increasing BMI is associated with more patient comorbidities and more persistent and long-standing AF. BMI ≥35 kg/m 2 adversely impacts ablation outcomes, and BMI ≥40 kg/m 2 increases minor complications. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Kallmünzer, Bernd; Breuer, Lorenz; Hering, Christiane; Raaz-Schrauder, Dorette; Kollmar, Rainer; Huttner, Hagen B; Schwab, Stefan; Köhrmann, Martin
2012-04-01
Anticoagulation is a highly effective secondary prevention in patients with cardioembolic stroke and atrial fibrillation/flutter (AF). However, the condition remains underdiagnosed, because paroxysmal AF may be missed by diagnostic tests in the acute phase. In this study, the sensitivity of AF detection was assessed for serial electrocardiographic recordings and continuous stroke unit telemetric monitoring with or without a structured algorithm to analyze telemetric data (SEA-AF). Three hundred forty-six consecutive patients with acute ischemic stroke were prospectively included and subjected to standard telemetric monitoring. In addition, telemetric data were separately analyzed following SEA-AF, consisting of a structured evaluation of episodes with high risk for AF and a chronological beat-to-beat screening of the full registration. Serial electrocardiograms were conducted in 24-hour intervals. Median effective telemetry monitoring time was 75.5 hours (interquartile range 64-86 hours). Overall, AF was diagnosed in 119 of 346 patients (34.4%). The structured reading algorithm was the most sensitive method to detected AF. Conventional telemetry and serial electrocardiographic assessments were less effective. However, only 35% of patients with previously documented paroxysmal AF and negative baseline electrocardiogram demonstrated AF episodes during monitoring. Continuous stroke unit telemetry using SEA-AF shows a significantly higher detection rate for AF compared with daily electrocardiographic assessments and standard telemetry without structured reading. The low overall probability to detect paroxysmal AF with either method during the first days after stroke demonstrates the urgent need for complementary diagnostic strategies such as long-term monitoring and frequent follow-up assessments. Clinical Trial Registration- URL: www.clinicaltrials.gov. Unique identifier: NCT01177748.
Singer, Daniel E; Albers, Gregory W; Dalen, James E; Fang, Margaret C; Go, Alan S; Halperin, Jonathan L; Lip, Gregory Y H; Manning, Warren J
2008-06-01
This chapter about antithrombotic therapy in atrial fibrillation (AF) is part of the American College of Chest Physicians Evidence-Based Guidelines Clinical Practice Guidelines (8th Edition). Grade 1 recommendations indicate that most patients would make the same choice and Grade 2 suggests that individual patient's values may lead to different choices (for a full understanding of the grading see Guyatt et al, CHEST 2008; 133[suppl]:123S-131S). Among the key recommendations in this chapter are the following (all vitamin K antagonist [VKA] recommendations have a target international normalized ratio [INR] of 2.5; range 2.0-3.0, unless otherwise noted). In patients with AF, including those with paroxysmal AF, who have had a prior ischemic stroke, transient ischemic attack (TIA), or systemic embolism, we recommend long-term anticoagulation with an oral VKA, such as warfarin, because of the high risk of future ischemic stroke faced by this set of patients (Grade 1A). In patients with AF, including those with paroxysmal AF, who have two or more of the risk factors for future ischemic stroke listed immediately below, we recommend long-term anticoagulation with an oral VKA (Grade 1A). Two or more of the following risk factors apply: age >75 years, history of hypertension, diabetes mellitus, moderately or severely impaired left ventricular systolic function and/or heart failure. In patients with AF, including those with paroxysmal AF, with only one of the risk factors listed immediately above, we recommend long-term antithrombotic therapy (Grade 1A), either as anticoagulation with an oral VKA, such as warfarin (Grade 1A), or as aspirin, at a dose of 75-325 mg/d (Grade 1B). In these patients at intermediate risk of ischemic stroke we suggest a VKA rather than aspirin (Grade 2A). In patients with AF, including those with paroxysmal AF, age < or =75 years and with none of the other risk factors listed above, we recommend long-term aspirin therapy at a dose of 75-325 mg/d (Grade 1B), because of their low risk of ischemic stroke. For patients with atrial flutter, we recommend that antithrombotic therapy decisions follow the same risk-based recommendations as for AF (Grade 1C). For patients with AF and mitral stenosis, we recommend long-term anticoagulation with an oral VKA (Grade 1B). For patients with AF and prosthetic heart valves we recommend long-term anticoagulation with an oral VKA at an intensity appropriate for the specific type of prosthesis (Grade 1B). See CHEST 2008; 133(suppl):593S-629S. For patients with AF of > or =48 h or of unknown duration for whom pharmacologic or electrical cardioversion is planned, we recommend anticoagulation with an oral VKA, such as warfarin, for 3 weeks before elective cardioversion and for at least 4 weeks after sinus rhythm has been maintained (Grade 1C). For patients with AF of > or = 48 h or of unknown duration undergoing pharmacological or electrical cardioversion, we also recommend either immediate anticoagulation with unfractionated IV heparin, or low-molecular-weight heparin (LMWH), or at least 5 days of warfarin by the time of cardioversion (achieving an INR of 2.0-3.0) as well as a screening multiplane transesophageal echocardiography (TEE). If no thrombus is seen, cardioversion is successful, and sinus rhythm is maintained, we recommend anticoagulation for at least 4 weeks. If a thrombus is seen on TEE, then cardioversion should be postponed and anticoagulation should be continued indefinitely. We recommend obtaining a repeat TEE before attempting later cardioversion (Grade 1B addressing the equivalence of TEE-guided vs non-TEE-guided cardioversion). For patients with AF of known duration <48 h, we suggest cardioversion without prolonged anticoagulation (Grade 2C). However, in patients without contraindications to anticoagulation, we suggest beginning IV heparin or LMWH at presentation (Grade 2C).
Evolution of Force Sensing Technologies.
Shah, Dipen
2017-06-01
In order to Improve the procedural success and long-term outcomes of catheter ablation techniques for atrial fibrillation (AF), an Important unfulfilled requirement is to create durable electrophysiologically complete lesions. Measurement of contact force (CF) between the catheter tip and the target tissue can guide physicians to optimise both mapping and ablation procedures. Contact force can affect lesion size and clinical outcomes following catheter ablation of AF. Force sensing technologies have matured since their advent several years ago, and now allow the direct measurement of CF between the catheter tip and the target myocardium in real time. In order to obtain complete durable lesions, catheter tip spatial stability and stable contact force are important. Suboptimal energy delivery, lesion density/contiguity and/or excessive wall thickness of the pulmonary vein-left atrial (PV-LA) junction may result in conduction recovery at these sites. Lesion assessment tools may help predict and localise electrical weak points resulting in conduction recovery during and after ablation. There is increasing clinical evidence to show that optimal use of CF sensing during ablation can reduce acute PV re-conduction, although prospective randomised studies are desirable to confirm long-term favourable clinical outcomes. In combination with optimised lesion assessment tools, contact force sensing technology has the potential to become the standard of care for all patients undergoing AF catheter ablation.
Is AF Ablation Cost Effective?
Martin-Doyle, William; Reynolds, Matthew R.
2010-01-01
The use of catheter ablation to treat AF is increasing rapidly, but there is presently an incomplete understanding of its cost-effectiveness. AF ablation procedures involve significant up-front expenditures, but multiple randomized trials have demonstrated that ablation is more effective than antiarrhythmic drugs at maintaining sinus rhythm in a second-line and possibly first-line rhythm control setting. Although truly long-term data are limited, ablation, as compared with antiarrrhythmic drugs, also appears associated with improved symptoms and quality of life and a reduction in downstream hospitalization and other health care resource utilization. Several groups have developed cost effectiveness models comparing AF ablation primarily to antiarrhythmic drugs and the model results suggest that ablation likely falls within the range generally accepted as cost-effective in developed nations. This paper will review available information on the cost-effectiveness of catheter ablation for the treatment of atrial fibrillation, and discuss continued areas of uncertainty where further research is required. PMID:20936083
O'Neal, Wesley T; Efird, Jimmy T; Davies, Stephen W; Choi, Yuk Ming; Anderson, Curtis A; Kindell, Linda C; O'Neal, Jason B; Ferguson, T Bruce; Chitwood, W Randolph; Kypson, Alan P
2013-01-01
Preoperative atrial fibrillation (AF) is associated with increased morbidity and mortality after open heart surgery. However, the impact of preoperative AF on long-term survival after open heart surgery has not been widely examined in rural populations. Patients from rural regions are less likely to receive treatment for cardiac conditions and to have adequate medical insurance coverage. To examine the influence of preoperative AF on long-term survival following open heart surgery in rural eastern North Carolina. Long-term survival was compared in patients with and without preoperative AF after coronary artery bypass grafting (CABG) and CABG plus valve (CABG + V) surgery between 2002 and 2011. Hazard ratios (HR) and 95% confidence intervals (CI) were computed using a Cox regression model. The study population consisted of 5438 patients. A total of 263 (5%) patients had preoperative AF. Preoperative AF was an independent predictor of long-term survival (open heart surgery: adjusted HR = 1.6, 95% CI = 1.3-2.0; CABG: adjusted HR = 1.6, 95% CI = 1.3-2.1; CABG + V: adjusted HR = 1.6, 95% CI = 1.1-2.3). Preoperative AF is an important predictor of long-term survival after open heart surgery in this rural population. Copyright © 2013 Elsevier Inc. All rights reserved.
Golwala, Harsh; Jackson, Larry R; Simon, DaJuanicia N; Piccini, Jonathan P; Gersh, Bernard; Go, Alan S; Hylek, Elaine M; Kowey, Peter R; Mahaffey, Kenneth W; Thomas, Laine; Fonarow, Gregg C; Peterson, Eric D; Thomas, Kevin L
2016-04-01
Significant racial/ethnic differences exist in the incidence of atrial fibrillation (AF). However, less is known about racial/ethnic differences in quality of life (QoL), treatment, and outcomes associated with AF. Using data from the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation, we compared clinical characteristics, QoL, management strategies, and long-term outcomes associated with AF among various racial/ethnic groups. We analyzed 9,542 participants with AF (mean age 74 ± 11 years, 43% women, 91% white, 5% black, 4% Hispanic) from 174 centers. Compared with AF patients identified as white race, patients identified as Hispanic ethnicity and those identified as black race were younger, were more often women, and had more cardiac and noncardiac comorbidities. Black patients were more symptomatic with worse QoL and were less likely to be treated with a rhythm control strategy than other racial/ethnic groups. There were no significant racial/ethnic differences in CHA2DS2-VASc stroke or ATRIA bleeding risk scores and rates of oral anticoagulation use were similar. However, racial and ethnic minority populations treated with warfarin spent a lower median time in therapeutic range of international normalized ratio (59% blacks vs 68% whites vs 62% Hispanics, P < .0001). There was no difference in long-term outcomes associated with AF between the 3 groups at a median follow-up of 2.1 years. Relative to white and Hispanic patients, black patients with AF had more symptoms, were less likely to receive rhythm control interventions, and had lower quality of warfarin management. Despite these differences, clinical events at 2 years were similar by race and ethnicity. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Žukovič, Milan; Tomita, Yusuke; Kamiya, Y.
2017-07-01
We study critical and magnetic properties of a bilayer Ising system consisting of two triangular planes A and B, with the antiferromagnetic (AF) coupling JA and the ferromagnetic (FM) one JB for the respective layers, which are coupled by the interlayer interaction JAB by using Monte Carlo simulations. When JA and JB are of the same order, the unfrustrated FM plane orders first at a high temperature Tc 1˜JB . The spontaneous FM order then exerts influence on the other frustrated AF plane as an effective magnetic field, which subsequently induces a ferrimagnetic order in this plane at low temperatures below Tc 2. When short-range order is developed in the AF plane while the influence of the FM plane is still small, there appears a preemptive Berezinskii-Kosterlitz-Thouless-type pseudocritical crossover regime just above the ferrimagnetic phase transition point, where the short-distance behavior up to a rather large length scale exponentially diverging in ∝JA/T is controlled by a line of Gaussian fixed points at T =0 . In the crossover region, a continuous variation in the effective critical exponent 4/9 ≲ηeff≲1/2 is observed. The phase diagram by changing the ratio JA/JB is also investigated.
Martins, Raphael P; Kaur, Kuljeet; Hwang, Elliot; Ramirez, Rafael J; Willis, B Cicero; Filgueiras-Rama, David; Ennis, Steven R; Takemoto, Yoshio; Ponce-Balbuena, Daniela; Zarzoso, Manuel; O'Connell, Ryan P; Musa, Hassan; Guerrero-Serna, Guadalupe; Avula, Uma Mahesh R; Swartz, Michael F; Bhushal, Sandesh; Deo, Makarand; Pandit, Sandeep V; Berenfeld, Omer; Jalife, José
2014-04-08
Little is known about the mechanisms underlying the transition from paroxysmal to persistent atrial fibrillation (AF). In an ovine model of long-standing persistent AF we tested the hypothesis that the rate of electric and structural remodeling, assessed by dominant frequency (DF) changes, determines the time at which AF becomes persistent. Self-sustained AF was induced by atrial tachypacing. Seven sheep were euthanized 11.5±2.3 days after the transition to persistent AF and without reversal to sinus rhythm; 7 sheep were euthanized after 341.3±16.7 days of long-standing persistent AF. Seven sham-operated animals were in sinus rhythm for 1 year. DF was monitored continuously in each group. Real-time polymerase chain reaction, Western blotting, patch clamping, and histological analyses were used to determine the changes in functional ion channel expression and structural remodeling. Atrial dilatation, mitral valve regurgitation, myocyte hypertrophy, and atrial fibrosis occurred progressively and became statistically significant after the transition to persistent AF, with no evidence for left ventricular dysfunction. DF increased progressively during the paroxysmal-to-persistent AF transition and stabilized when AF became persistent. Importantly, the rate of DF increase correlated strongly with the time to persistent AF. Significant action potential duration abbreviation, secondary to functional ion channel protein expression changes (CaV1.2, NaV1.5, and KV4.2 decrease; Kir2.3 increase), was already present at the transition and persisted for 1 year of follow up. In the sheep model of long-standing persistent AF, the rate of DF increase predicts the time at which AF stabilizes and becomes persistent, reflecting changes in action potential duration and densities of sodium, L-type calcium, and inward rectifier currents.
Synthesis and Characterization of Ferromagnetic/Antiferromagnetic Perovskite Oxide Superlattices
NASA Astrophysics Data System (ADS)
Jia, Yue
Perovskite oxides span a diverse range of functional properties such as ferromagnetism, superconductivity, and ferroelectricity, which makes them promising candidate materials for applications such as sensors, energy conversion and data storage devices. With recent advances in thin film deposition techniques, the precise manipulation of atomic layers on the unit cell level make it possible to synthesize epitaxial thin film heterostructures consisting of layers with different properties. The structural compatibility of perovskite oxides allows them to be epitaxially grown in complex heterostructures such as superlattices with a large density of interfaces where the interplay between spin, charge, orbital, and lattice degrees of freedom gives rise to new behaviors. The ferromagnetic (FM)/antiferromagnetic (AF) interface is particularly interesting due to exchange coupling which is not only of interest for fundamental research but also is of great significance for industrial applications. Unlike metallic systems that have been studied for decades with wide ranges of applications in devices such as hard disk drives, thin films of complex metal oxides is a relatively new field. Perovskite oxides show much more diverse functional properties than metals and open new pathways for tailoring propertiestowards specific device applications. Epitaxial La0.7Sr0.3MnO3 (LSMO)/La 0.7Sr0.3FeO3 (LSFO) superlattices serve as model systems to explore the magnetic structure and exchange coupling at perovskite oxide interfaces. Earlier work suggested that (001)-oriented LSMO/LSFO superlattices with compensated AF spins at the interface display spin-flop coupling characterized by perpendicular alignment between the AF spin axes and the FM moments at a sublayer thickness of 6 unit cells (u.c.). Changing the crystallographic orientation of the interface from (001) to (111) introduces changes to factors such as the charge density of each stacking layer, the magnetic iiistructure of the AF layer at the interface, the symmetry of the lattice, and the orbital degeneracy. Therefore, different properties and exchange coupling mechanisms are expected. (111)-oriented LSMO/LSFO superlattices with sublayer thicknesses ranging from 3 to 60 u.c. were synthesized and characterized. Detailed analysis of their structural, electronic, and magnetic properties were performed using synchrotron radiation based resonant x-ray reflectivity, soft x-ray magnetic spectroscopy, and photoemission electron microscopy to explore the effect of sublayer thickness on the magnetic structure and exchange coupling at (111)-oriented perovskite oxide interfaces. Interfacial effects and ultrathin superlattice sublayers can stabilize orientations of the LSFO AF spin axis which differ from that of LSFO films and LSMO/LSFO bilayers. In the ultrathin limit (3 to 6 u.c.), it was found that the AF properties of the LSFO sublayers are preserved with an out-of-plane canting of the AF spin axis, while the FM properties of the LSMO sublayers are significantly depressed. For thicker LSFO layers (> 9 u.c.), the out-of-plane canting of the AF spin axis is only present in superlattices with thick LSMO sublayers. As a result, exchange coupling in the form of spin-flop coupling exists only in superlattices which display both robust ferromagnetism and out-of-plane canting of the AF spin axis. A portion of the AF moments can be reoriented by a moderate external magnetic field through spin-flop coupling with the FM LSMO sublayers that have low magnetocrystalline anisotropy in the (111) plane. The AF order in the spin-flop coupled superlattices was studied using angle-dependent x-ray magnetic linear dichroism. The AF order can be categorized into two types: majority of the AF moments cant out-of-the-plane of the film along the or directions depending on the LSFO layer thickness, while a minority portion lies within the (111) plane in different AF domains. The energy difference between domains with their spin axes along the in-plane or out-of-plane directions is small, and the magnetic order of AF thin films is far ivmore complex than in bulk LSFO. The complex AF structure in these (111)-oriented LSMO/LSFO superlattices illustrates that complex metal oxide heterostructures can serve as fertile ground for discovery of new magnetic phases, which have potential applications in next generation information technology devices.
Long-term outcomes following high intensity focused ultrasound ablation for atrial fibrillation.
Davies, Edward J; Bazerbashi, Samer; Asopa, Sanjay; Haywood, Guy; Dalrymple-Hay, Malcolm
2014-01-01
The aim of this study is to assess the safety and efficacy of the Epicor high intensity focused ultrasound (St. Jude, Inc.®, Minneapolis, MN, USA) system using seven-day ambulatory electrocardiogram (ECG) monitoring over a two-year follow-up period. One hundred and ten patients undergoing ablation were included from a single center between January 2006 and December 2009. Rhythm was assessed using seven-day ambulatory ECG or permanent pacemaker interrogation. Seventeen patients were lost to follow-up, seven through death. Results were reported according to atrial fibrillation (AF) class preoperatively: paroxysmal, persistent, and long-standing persistent (LSP). Forty-nine percent of patients remained in sinus rhythm at greater than two years. The percentage of patients in sinus rhythm according to preoperative AF class were 81% (paroxysmal AF), 56% (persistent AF), and 18% (long-standing AF). The class of AF prior to surgery, left atrium size, and body mass index determined the long-term outcome. There were no procedure-related complications. We conclude that high intensity focused ultrasound ablation for atrial fibrillation using the Epicor system is safe and effective for surgical patients with paroxysmal AF. The persistent and LSP AF results suggest that alternative ablation strategies should be considered for these patients. © 2013 Wiley Periodicals, Inc.
76 FR 59116 - Procurement List; Additions
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-23
... NSN: AF110--Shirt, Class A/Primary Duty, USAF, Men's, Long Sleeve, Dark Navy Blue, Numerous Sizes. NSN: AF111--Shirt, Class A/Primary Duty, USAF, Women's, Long Sleeve, Dark Navy Blue, Numerous Sizes. NSN: AF120--Shirt, Class A/Primary Duty, USAF, Men's, Short Sleeve, Dark Navy Blue, Numerous Sizes. NSN...
Bossard, Matthias; Knecht, Sven; Aeschbacher, Stefanie; Buechel, Ronny R; Hochgruber, Thomas; Zimmermann, Andreas J; Kessel-Schaefer, Arnheid; Stephan, Frank-Peter; Völlmin, Gian; Pradella, Maurice; Sticherling, Christian; Osswald, Stefan; Kaufmann, Beat A; Conen, David; Kühne, Michael
2017-06-01
Arrhythmia recurrence after atrial fibrillation (AF) ablation remains high and requires repeat interventions in a substantial number of patients. We assessed the value of conventional and 3-D echocardiography to predict AF recurrence. Consecutive patients undergoing AF ablation by means of pulmonary vein isolation were included in a prospective registry. Echocardiograms were obtained prior to the ablation procedure, and analyzed offline in a standardized manner, including 3-D left atrial (LA) volumetry and determination of LA function and sphericity. The primary endpoint, AF recurrence (>30 seconds) between 3 to 12 months after AF ablation, was independently adjudicated. We included 276 patients (73% male, mean age 59.9 ± 9.9 years). Paroxysmal and persistent AF were present in 178 (64%) and 98 (36%) patients, respectively. Mean left ventricular ejection fraction and indexed LA volume in 3-D (LAVI) were 52 ± 12% and 42 ± 13 mL/m 2 , respectively. AF recurrence was observed in 110 (40%) patients after a single procedure. Median (interquartile range) time to AF recurrence was 123 (92; 236) days. In multivariable Cox regression models, the only predictors for AF recurrence were the minimal, maximal, and indexed 3-D LA volumes, P = 0.024, P = 0.016, and P = 0.014, respectively. Quartile specific analysis of 3-D LAVI showed an HR of 1.885 (95%CI 1.066-3.334; P for trend = 0.015) for the highest compared to the lowest quartile. Our results show the important role of LA volume for the long-term freedom from arrhythmia after AF ablation. These data also highlight the potential of 3-D echocardiography in this context and may facilitate patient selection for AF ablation. © 2017 Wiley Periodicals, Inc.
Guhl, Emily N; Schlusser, Courtney L; Henault, Lori E; Bickmore, Timothy W; Kimani, Everlyne; Paasche-Orlow, Michael K; Magnani, Jared W
2017-11-01
Atrial Fibrillation (AF) is a common cardiac arrhythmia that is challenging for patients and adversely impacts health-related quality of life (HRQoL). Long-term management of AF requires that patients adhere to complex therapies, understand difficult terminology, navigate subspecialty care, and have continued symptom monitoring with the goal of preventing adverse outcomes. Continued interventions to ameliorate the patient experience of AF are essential. The Atrial Fibrillation health Literacy Information Technology Trial (AF-LITT; NCT03093558) is an investigator-initiated, 2-arm randomized clinical trial (RCT). This RCT is a pilot in order to implement a novel, smartphone-based intervention to address the patient experience of AF. This pilot RCT will compare a combination of the Embodied Conversational Agent (ECA) and the Alive Cor Kardia Mobile heart rhythm monitor to the current standard of care. The study will enroll 180 adults with non-valvular AF who are receiving anticoagulation for stroke prevention and randomize them to receive a 30-day intervention (smartphone-based ECA/Kardia) or standard of care, which will include a symptom and adherence journal. The primary end-points are improvement in HRQoL and self-reported adherence to anticoagulation. The secondary end-points are the acceptability of the intervention to participants, its use by participants, and acceptability to referring physicians. The AF-LITT pilot aims to evaluate the efficacy of the ECA/Kardia to improve HRQoL and anticoagulant adherence, and to guide its implementation in a larger, multicenter clinical trial. The intervention has potential to improve HRQoL, adherence, and health care utilization in individuals with chronic AF. Copyright © 2017 Elsevier Inc. All rights reserved.
Guhl, Emily N.; Schlusser, Courtney L.; Henault, Lori E.; Bickmore, Timothy W.; Kimani, Everlyne; Paasche-Orlow, Michael K.; Magnani, Jared W.
2017-01-01
Background Atrial Fibrillation (AF) is a common cardiac arrhythmia that is challenging for patients and adversely impacts health-related quality of life (HRQoL). Long-term management of AF requires that patients adhere to complex therapies, understand difficult terminology, navigate subspecialty care, and have continued symptom monitoring with the goal of preventing adverse outcomes. Continued interventions to ameliorate the patient experience of AF are essential. Design The Atrial Fibrillation health Literacy Information Technology Trial (AF-LITT; NCT03093558) is an investigator-initiated, 2-arm randomized clinical trial (RCT). This RCT is a pilot in order to implement a novel, smartphone-based intervention to address the patient experience of AF. This pilot RCT will compare a combination of the embodied conversational agent (ECA) and the Alive Cor Kardia Mobile heart rhythm monitor to the current standard of care. The study will enroll 180 adults with non-valvular AF who are receiving anticoagulation for stroke prevention and randomize them to receive a 30-day intervention (smartphone-based ECA/Kardia) or standard of care, which will include a symptom and adherence journal. The primary end-points are improvement in HRQoL and self-reported adherence to anticoagulation. The secondary end-points are the acceptability of the intervention to participants, its use by participants, and acceptability to referring physicians. Conclusions The AF-LITT pilot aims to evaluate the efficacy of the ECA/Kardia to improve HRQoL and anticoagulant adherence, and to guide its implementation in a larger, multicenter clinical trial. The intervention has potential to improve HRQoL, adherence, and health care utilization in individuals with chronic AF. PMID:28923492
Is there still a role for the classical Cox-Maze III?
Yap, Cheng-Hon; Prior, David; Kenny, James; Zimmet, Adam; Chao, Victor; Mooney, Donald; Yii, Michael
2006-05-01
The incidence of surgery for atrial fibrillation (AF) is rising, paralleled by an increase in the types of lesion sets and energy sources used. These alternate energy sources have simplified the surgery at the expense of increased cost of consumables. The classical Cox-Maze III is the gold standard therapy with a proven efficacy in curing AF. Our complete experience with this procedure is presented. All 28 patients undergoing the classical Cox-Maze III procedure at our institution underwent preoperative assessment and were followed prospectively. Twenty-eight patients underwent the Cox-Maze III procedure between January 2001 and May 2003. Their mean age was 65 years (range, 44-80 years). Twenty-five patients had concomitant cardiac procedures. Mean duration of AF was 8.3 years. Permanent AF was present in 82%. Mean follow-up time was 15 +/- 8 months (range, 4-30 months). There were no perioperative or late deaths, or thromboembolic events. Sixty-one per cent had early (<3 months) atrial arrhythmia. Freedom from AF at most recent clinical follow up was 93%. Freedom from late atrial arrhythmia was 82%. Freedom from late AF or atrial flutter by pacemaker interrogation or Holter assessment was 77%. Anti-arrhythmic medication use was reduced. New York Heart Association class improved from an average of 2.8 preoperatively to 1.3 postoperatively. The result of the present study shows the safety and efficacy of the classical Cox-Maze III procedure. With the advantage of proven long-term efficacy, demonstrable safety and avoidance of costly technology, the Cox-Maze III should not be discounted as a treatment option in patients because of its perceived complexity.
Ablating Atrial Fibrillation: Customizing Lesion Sets Guided by Rotor Mapping
Zaman, Junaid A. B.; Narayan, Sanjiv M.
2015-01-01
Ablation occupies an increasing role in the contemporary management of atrial fibrillation (AF), but results are suboptimal, particularly for persistent AF. While an anatomic approach to ablation is a highly efficacious and safe method to isolate pulmonary vein (PV) triggers, recurrence of AF is not always associated with PV reconnection, and there is compelling evidence that non-PV sites sustain AF after it is triggered. Recent developments in wide-area mapping and signal processing now identify rotors in the vast majority of AF patients that sustain AF and whose elimination improves long-term freedom from AF in multicenter studies. Investigators have now demonstrated rotor and focal sources for AF that show many analogous properties between approaches: they lie in spatially reproducible regions temporally over hours to days, and they are amenable to targeted ablation. This review outlines the rationale and technical developments supporting this mechanistic paradigm for human AF, and discusses how rotor mapping may be implemented for individual patient customization of lesion sets. Mechanistic studies are required to explain why rotor elimination (or other ablation approaches) producing long-term elimination of AF may not always terminate AF acutely, how AF correlates with structural changes on magnetic resonance imaging, and how these findings can be integrated clinically with current ablation strategies to improve patient outcomes. PMID:26306123
Ablating Atrial Fibrillation: Customizing Lesion Sets Guided by Rotor Mapping.
Zaman, Junaid A B; Narayan, Sanjiv M
2015-01-01
Ablation occupies an increasing role in the contemporary management of atrial fibrillation (AF), but results are suboptimal, particularly for persistent AF. While an anatomic approach to ablation is a highly efficacious and safe method to isolate pulmonary vein (PV) triggers, recurrence of AF is not always associated with PV reconnection, and there is compelling evidence that non-PV sites sustain AF after it is triggered. Recent developments in wide-area mapping and signal processing now identify rotors in the vast majority of AF patients that sustain AF and whose elimination improves long-term freedom from AF in multicenter studies. Investigators have now demonstrated rotor and focal sources for AF that show many analogous properties between approaches: they lie in spatially reproducible regions temporally over hours to days, and they are amenable to targeted ablation. This review outlines the rationale and technical developments supporting this mechanistic paradigm for human AF, and discusses how rotor mapping may be implemented for individual patient customization of lesion sets. Mechanistic studies are required to explain why rotor elimination (or other ablation approaches) producing long-term elimination of AF may not always terminate AF acutely, how AF correlates with structural changes on magnetic resonance imaging, and how these findings can be integrated clinically with current ablation strategies to improve patient outcomes.
Jump performance and augmented feedback: immediate benefits and long-term training effects.
Keller, Martin; Lauber, Benedikt; Gehring, Dominic; Leukel, Christian; Taube, Wolfgang
2014-08-01
Drop jumps and their adaptations to training have been extensively investigated. However, the influence of augmented feedback (aF) on stretch-shortening cycle (SSC) was not scrutinized so far despite the well-known positive effects of aF on motor performance and motor learning. The aim of the present study was therefore to investigate the effects of aF by evaluating immediate within-session effects and long-term adaptations. 34 participants were assigned to three groups that trained drop jumps with different relative frequencies of aF about their jump height: 100%, 50%, or 0%. A significant within-session effect of aF on jump height was observed before and also after the training period (pre: +4.6%; post: +2.6%). In the long-term (comparing pre- to post-measurement), the 100% group showed the greatest increase in jump height (+14%), followed by the 50% (+10%) and the 0% group (+6%). The importance of aF on drop jumps is therefore twofold: (i) to immediately increase jump performance and (ii) to improve long-term training efficacy. In contrast to the proposition of the guidance hypothesis, high frequency of aF seems to be beneficial when maximizing SSC-performance. As jump height cannot be quantified without objective technical measures it is recommended to include them into daily training. Copyright © 2014 Elsevier B.V. All rights reserved.
Relevance of Conduction Disorders in Bachmann's Bundle During Sinus Rhythm in Humans.
Teuwen, Christophe P; Yaksh, Ameeta; Lanters, Eva A H; Kik, Charles; van der Does, Lisette J M E; Knops, Paul; Taverne, Yannick J H J; van de Woestijne, Pieter C; Oei, Frans B S; Bekkers, Jos A; Bogers, Ad J J C; Allessie, Maurits A; de Groot, Natasja M S
2016-05-01
Bachmann's bundle (BB) is considered to be the main route of interatrial conduction and to play a role in development of atrial fibrillation (AF). The goals of this study are to characterize the presence of conduction disorders in BB during sinus rhythm and to study their relation with AF. High-resolution epicardial mapping (192 unipolar electrodes, interelectrode distance: 2 mm) of sinus rhythm was performed in 185 patients during coronary artery bypass surgery of whom 13 had a history of paroxysmal AF. Continuous rhythm monitoring was used to detect postoperative AF during the first 5 postoperative days. In 67% of the patients, BB was activated from right to left; in the remaining patients from right and middle (21%), right, central, and left (8%), or central (4%) site. Mean effective conduction velocity was 89 cm/s. Conduction block was present in most patients (75%; median 1.1%, range 0-12.8) and was higher in patients with paroxysmal AF compared with patients without a history of AF (3.2% versus 0.9%; P=0.03). A high amount of conduction block (>4%) was associated with de novo postoperative AF (P=0.02). Longitudinal lines of conduction block >10 mm were also associated with postoperative AF (P=0.04). BB may be activated through multiple directions, but the predominant route of conduction is from right to left. Conduction velocity across BB is around 90 cm/s. Conduction is blocked in both longitudinal and transverse direction in the majority of patients. Conduction disorders, particularly long lines of longitudinal conduction block, are more pronounced in patients with AF episodes. © 2016 American Heart Association, Inc.
The cox-maze procedure for lone atrial fibrillation: a single-center experience over 2 decades.
Weimar, Timo; Schena, Stefano; Bailey, Marci S; Maniar, Hersh S; Schuessler, Richard B; Cox, James L; Damiano, Ralph J
2012-02-01
The Cox-Maze procedure (CMP) has achieved high success rates in the therapy of atrial fibrillation (AF) while becoming progressively less invasive. This report evaluates our experience with the CMP in the treatment of lone AF over 2 decades and compares the original cut-and-sew CMP-III to the ablation-assisted CMP-IV, which uses bipolar radiofrequency and cryoenergy to create the original lesion pattern. Data were collected prospectively on 212 consecutive patients (mean age, 53.5±10.4 years; 78% male) who underwent a stand-alone CMP from 1992 through 2010. The median duration of preoperative AF was 6 (interquartile range, 2.9-11.5) years, with 48% paroxysmal and 52% persistent or long-standing persistent AF. Univariate analysis with preoperative and perioperative variables used as covariates for the CMP-III (n=112) and the CMP-IV (n=100) was performed. Overall, 30-day mortality was 1.4%, with no intraoperative deaths. Freedom from AF was 93%, and freedom from AF off antiarrhythmics was 82%, at a mean follow-up time of 3.6±3.1 years. Freedom from symptomatic AF at 10 years was 85%. Only 1 late stroke occurred, with 80% of patients not receiving anticoagulation therapy. The less invasive CMP-IV had significantly shorter cross-clamp times (41±13 versus 92±26 minutes; P<0.001) while achieving high success rates, with 90% freedom from AF and 84% freedom from AF off antiarrhythmics at 2 years. The CMP, although simplified and shortened by alternative energy sources, has excellent results, even with improved follow-up and stricter definition of failure.
Long-term influence of body mass index on cardiovascular events after atrial fibrillation ablation.
Bunch, T Jared; May, Heidi T; Bair, Tami L; Crandall, Brian G; Cutler, Michael J; Jacobs, Victoria; Mallender, Charles; Muhlestein, Joseph B; Osborn, Jeffrey S; Weiss, J Peter; Day, John D
2016-09-01
Catheter ablation of atrial fibrillation (AF) is an established therapeutic rhythm approach in symptomatic patients. Obesity is a dominant driver of AF recurrence after ablation. However, being both overweight and underweight drives long-term cardiac and general health risks. Long-term data are needed to understand the influence of body mass index (BMI) on outcomes after ablation in regard to arrhythmia recurrence and cardiovascular outcomes. All patients who underwent an index ablation with a BMI recorded and at least 3 years of follow-up were included (n = 1558). The group was separated and compared by index ablation BMI status (≤20, 21-25, 26-30, >30 kg/m(2)). Long-term outcomes included AF recurrence, stroke/TIA, heart failure (HF) hospitalization, and death. Patients with advancing BMI status were more likely to be male and have hypertension, a smoking history, diabetes, HF, and a prior cardioversion. Patients with a BMI ≤20 were more likely to have a moderate-high congestive heart failure, hypertension, age >75, diabetes, stroke (CHADS2) score. At 3 years, recurrence rates of AF increased significantly with increasing BMI status (p = 0.02); paradoxically, there was a trend for increased stroke risk with decreasing BMI (p = 0.06). Long-term death rates tended to increase inversely with BMI status, and HF rates were greatest in the highest and lowest BMI groups. Lower weight at AF ablation lowers arrhythmia recurrence risk. However, AF ablation patients who are normal or underweight remain at high risk of other cardiovascular outcomes including increased stroke risk with less AF burden.
Hong, Sung-Ryong; Na, Wonshik; Kang, Jang-Mook
2010-01-01
This study suggests an approach to effective transmission of multimedia content in a rapidly changing Internet environment including smart-phones. Guaranteeing QoS in networks is currently an important research topic. When transmitting Assured Forwarding (AF) packets in a Multi-DiffServ network environment, network A may assign priority in an order AF1, AF2, AF3 and AF4; on the other hand, network B may reverse the order to a priority AF4, AF3, AF2 and AF1. In this case, the AF1 packets that received the best quality of service in network A will receive the lowest in network B, which may result in dropping of packets in network B and vice versa. This study suggests a way to guarantee QoS between hosts by minimizing the loss of AF packet class when one network transmits AF class packets to another network with differing principles. It is expected that QoS guarantees and their experimental value may be utilized as principles which can be applied to various mobile-web environments based on smart-phones.
Hong, Sung-Ryong; Na, Wonshik; Kang, Jang-Mook
2010-01-01
This study suggests an approach to effective transmission of multimedia content in a rapidly changing Internet environment including smart-phones. Guaranteeing QoS in networks is currently an important research topic. When transmitting Assured Forwarding (AF) packets in a Multi-DiffServ network environment, network A may assign priority in an order AF1, AF2, AF3 and AF4; on the other hand, network B may reverse the order to a priority AF4, AF3, AF2 and AF1. In this case, the AF1 packets that received the best quality of service in network A will receive the lowest in network B, which may result in dropping of packets in network B and vice versa. This study suggests a way to guarantee QoS between hosts by minimizing the loss of AF packet class when one network transmits AF class packets to another network with differing principles. It is expected that QoS guarantees and their experimental value may be utilized as principles which can be applied to various mobile-web environments based on smart-phones. PMID:22163453
Characterizing the antiferromagnetic ordering of fermions in a compensated optical lattice
NASA Astrophysics Data System (ADS)
Duarte, P. M.; Hart, R. A.; Yang, T. L.; Liu, X.; Hulet, R. G.; Paiva, T. C. L.; Huse, D.; Scalettar, R.; Trivedi, N.
2014-05-01
We realize the Fermi-Hubbard model with fermionic 6Li atoms in a three-dimensional, red-detuned optical lattice. The lattice is compensated by the addition of three blue-detuned gaussian beams which overlap each of the lattice laser beams, but are not retro-reflected. Using the compensated lattice potential, we have reached temperatures low enough to produce antiferromagnetic (AF) spin correlations, which we detect via Bragg scattering of light. The variation of the measured AF correlations as a function of the Hubbard interaction strength, U / t , provides a way to determine the temperature of the atoms in the lattice by comparison with quantum Monte Carlo calculations. This method suggests our temperature is in the range of 2-3 times the Néel ordering temperature. In this poster we present our Bragg scattering results along with our studies of the effect of the compensating potential in helping us cool the atoms in the lattice and also enlarge the size of the AF phase. Work supported by DARPA, ONR, NSF and The Welch Foundation.
NASA Astrophysics Data System (ADS)
Balaev, D. A.; Popkov, S. I.; Krasikov, A. A.; Balaev, A. D.; Dubrovskiy, A. A.; Stolyar, S. V.; Yaroslavtsev, R. N.; Ladygina, V. P.; Iskhakov, R. S.
2017-10-01
The cross-breeding problem of the temperature dependence of the antiferromagnetic susceptibility of ferrihydrite nanoparticles is considered. Iron ions Fe3+ in ferrihydrite are ordered antiferromagnetically; however, the existence of defects on the surface and in the bulk of nanoparticles induces a noncompensated magnetic moment that leads to a typical superparamagnetic behavior of ensemble of the nanoparticles with a characteristic blocking temperature. In an unblocked state, magnetization curves of such objects are described as a superposition of the Langevin function and the linear-in-field contribution of the antiferromagnetic "core" of the nanoparticles. According to many studies of the magnetization curves performed on ferrihydrite (and related ferritin) nanoparticles in fields to 60 kOe, dependence χAF( T) decreases as temperature increases, which was related before to the superantiferromagnetism effect. As the magnetic field range increases to 250 kOe, the values of χAF obtained from an analysis of the magnetization curves become lower in magnitude; however, the character of the temperature evolution of χAF is changed: now, dependence χAF( T) is an increasing function. The latter is typical for a system of AF particles with random orientation of the crystallographic axes. To correctly determine the antiferromagnetic susceptibility of AF nanoparticles (at least, ferrihydrite) and to search for effects related to the superantiferromagnetism effect, it is necessary to use in experiments the range of magnetic field significantly higher than that the standard value 60 kOe used in most experiments. The study of the temperature evolution of the magnetization curves shows that the observed crossover is due to the existence of small magnetic moments in the samples.
Potpara, Tatjana S; Lip, Gregory Y H
2015-01-01
Ever since the original description of a 'peculiar pulse irregularity', atrial fibrillation (AF) has been studied extensively and has come a long journey from the recognition of its cardiac origins, to the modern concept of AF as a serious public health challenge with profound social and economic implications. This arrhythmia affects around 2% of adult population, and the most common underlying heart diseases accompanying AF in the modern era are hypertension, heart failure and coronary artery disease, as well as valvular heart diseases and numerous other cardiac as well as non-cardiac disorders which have been shown to predispose to AF. On occasions, AF occurs in young otherwise apparently healthy individuals (so called 'lone AF'). For a long time, 'lone' AF has been believed to bear a favourable prognosis as compared to AF with underlying structural heart disease, but increasing evidence suggests that 'lone' AF patients represent a rather heterogeneous cohort, with highly variable individual risk profiles due to the presence of various subclinical cardiovascular risk factors or genetically determined subtle alterations at the cellular or molecular level. For these reasons, the existence of truly 'lone' AF has recently been questioned. In this review article, we present a brief history of the recognition of the public health burden of AF. We discuss some of the misconceptions and breakthroughs on modern knowledge on AF, including the rise (and fall) of the 'lone' AF concept.
Boriani, Giuseppe; Proietti, Marco; Laroche, Cécile; Fauchier, Laurent; Marin, Francisco; Nabauer, Michael; Potpara, Tatjana; Dan, Gheorghe-Andrei; Kalarus, Zbigniew; Diemberger, Igor; Tavazzi, Luigi; Maggioni, Aldo P; Lip, Gregory Y H
2018-05-01
Contemporary data regarding atrial fibrillation (AF) management and current use of oral anticoagulants (OACs) for stroke prevention are needed. The EURObservational Research Programme on AF (EORP-AF) Long-Term General Registry analysed consecutive AF patients presenting to cardiologists in 250 centres from 27 European countries. From 2013 to 2016, 11 096 patients were enrolled (40.7% female; mean age 69 ± 11 years). At discharge, OACs were used in 9379 patients (84.9%), with non-vitamin K antagonists (NOACs) accounting for 40.9% of OACs. Antiplatelet therapy alone was used by 20% of patients, while no antithrombotic treatment was prescribed in 6.4%. On multivariable analysis, age, hypertension, previous ischaemic stroke, symptomatic AF and planned cardioversion or ablation were independent predictors of OAC use, whereas lone AF, previous haemorrhagic events, chronic kidney disease and admission for acute coronary syndrome (ACS) or non-cardiovascular causes independently predicted OAC non-use. Regarding the OAC type, coronary artery disease, history of heart failure, or valvular heart disease, planned cardioversion and non-AF reasons for admission independently predicted the use of vitamin K antagonists (VKAs). Wide variability among the European regions was observed in the use of NOACs, independently from other clinical factors. The EORP-AF Long-Term General Registry provides a full picture of contemporary use of OAC in European AF patients. The overall rate of OACs use was generally high (84.9%), and a series of factors were associated with the prescription of OAC. A significant geographical heterogeneity in prescription of NOACs vs. VKAs was evident.
Atienza, Felipe; Almendral, Jesús; Jalife, José; Zlochiver, Sharon; Ploutz-Snyder, Robert; Torrecilla, Esteban G; Arenal, Angel; Kalifa, Jérôme; Fernández-Avilés, Francisco; Berenfeld, Omer
2009-01-01
Spectral analysis identifies localized sites of high-frequency activity during atrial fibrillation (AF). This study sought to determine the effectiveness of using real-time dominant frequency (DF) mapping for radiofrequency ablation of maximal DF (DFmax) sites and elimination of left-to-right frequency gradients in the long-term maintenance of sinus rhythm (SR) in AF patients. DF mapping was performed in 50 patients during ongoing AF (32 paroxysmal, 18 persistent), acquiring a mean of 117 +/- 38 points. Ablation was performed targeting DFmax sites, followed by circumferential pulmonary vein isolation. Ablation significantly reduced DFs (Hz) in the LA (7.9 +/- 1.4 vs. 5.7 +/- 1.3, P <.001), coronary sinus (CS) (5.7 +/- 1.1 vs. 5.3 +/- 1.2, P = .006), and RA (6.3 +/- 1.4 vs. 5.4 +/- 1.3, P <.001) abolishing baseline left-to-right atrial DF gradient (1.7 +/- 1.7 vs. 0.2 +/- 0.9; P <.001). Only a significant reduction in DFs in all chambers with a loss of the left-to-right atrial gradient after ablation was associated with a higher probability of long-term SR maintenance in both paroxysmal and persistent AF patients. After a mean follow-up of 9.3 +/- 5.4 months, 88% of paroxysmal and 56% of persistent AF patients were free of AF (P = .02). Ablation of DFmax sites was associated with a higher probability of remaining both free of arrhythmias (78% vs. 20%; P = .001) and free of AF (88% vs. 30%; P <.001). Radiofrequency ablation leading to elimination of LA-to-RA frequency gradients predicts long-term SR maintenance in AF patients.
Matějková, Adéla; Šteiner, Ivo
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. For long time it was considered as pure functional disorder, but in recent years, there were identified atrial locations, which are involved in the initiation and maintenance of this arrhythmia. These structural changes, so called remodelation, start at electric level and later they affect contractility and morphology. In this study we attempted to find a possible relation between morphological (scarring, amyloidosis, left atrial (LA) enlargement) and electrophysiological (ECG features) changes in patients with AF. We examined grossly and histologically 100 hearts of necropsy patients - 54 with a history of AF and 46 without AF. Premortem ECGs were evaluated. The patients with AF had significantly heavier heart, larger LA, more severely scarred myocardium of the LA and atrial septum, and more severe amyloidosis in both atria. Severity of amyloidosis was higher in LAs vs. right atria (RAs). Distribution of both fibrosis and amyloidosis was irregular. The most affected area was in the LA anterior wall. Patients with a history of AF and with most severe amyloidosis have more often abnormally long P waves. Finding of long P wave may contribute to diagnosis of a hitherto undisclosed atrial fibrillation.
Unified molecular field theory for collinear and noncollinear Heisenberg antiferromagnets
Johnston, David C.
2015-02-27
In this study, a unified molecular field theory (MFT) is presented that applies to both collinear and planar noncollinear Heisenberg antiferromagnets (AFs) on the same footing. The spins in the system are assumed to be identical and crystallographically equivalent. This formulation allows calculations of the anisotropic magnetic susceptibility χ versus temperature T below the AF ordering temperature T N to be carried out for arbitrary Heisenberg exchange interactions J ij between arbitrary neighbors j of a given spin i without recourse to magnetic sublattices. The Weiss temperature θ p in the Curie-Weiss law is written in terms of the Jmore » ij values and T N in terms of the J ij values and an assumed AF structure. Other magnetic and thermal properties are then expressed in terms of quantities easily accessible from experiment as laws of corresponding states for a given spin S. For collinear ordering these properties are the reduced temperature t=T/T N, the ratio f = θ p/T N, and S. For planar noncollinear helical or cycloidal ordering, an additional parameter is the wave vector of the helix or cycloid. The MFT is also applicable to AFs with other AF structures. The MFT predicts that χ(T ≤ T N) of noncollinear 120° spin structures on triangular lattices is isotropic and independent of S and T and thus clarifies the origin of this universally observed behavior. The high-field magnetization and heat capacity for fields applied perpendicular to the ordering axis (collinear AFs) and ordering plane (planar noncollinear AFs) are also calculated and expressed for both types of AF structures as laws of corresponding states for a given S, and the reduced perpendicular field versus reduced temperature phase diagram is constructed.« less
Unified molecular field theory for collinear and noncollinear Heisenberg antiferromagnets
NASA Astrophysics Data System (ADS)
Johnston, David C.
2015-02-01
A unified molecular field theory (MFT) is presented that applies to both collinear and planar noncollinear Heisenberg antiferromagnets (AFs) on the same footing. The spins in the system are assumed to be identical and crystallographically equivalent. This formulation allows calculations of the anisotropic magnetic susceptibility χ versus temperature T below the AF ordering temperature TN to be carried out for arbitrary Heisenberg exchange interactions Ji j between arbitrary neighbors j of a given spin i without recourse to magnetic sublattices. The Weiss temperature θp in the Curie-Weiss law is written in terms of the Ji j values and TN in terms of the Ji j values and an assumed AF structure. Other magnetic and thermal properties are then expressed in terms of quantities easily accessible from experiment as laws of corresponding states for a given spin S . For collinear ordering these properties are the reduced temperature t =T /TN , the ratio f =θp/TN , and S . For planar noncollinear helical or cycloidal ordering, an additional parameter is the wave vector of the helix or cycloid. The MFT is also applicable to AFs with other AF structures. The MFT predicts that χ (T ≤TN) of noncollinear 120∘ spin structures on triangular lattices is isotropic and independent of S and T and thus clarifies the origin of this universally observed behavior. The high-field magnetization and heat capacity for fields applied perpendicular to the ordering axis (collinear AFs) and ordering plane (planar noncollinear AFs) are also calculated and expressed for both types of AF structures as laws of corresponding states for a given S , and the reduced perpendicular field versus reduced temperature phase diagram is constructed.
Jin, Qi; Pehrson, Steen; Jacobsen, Peter Karl; Chen, Xu
2015-11-01
The objectives of this study were to assess the procedural outcomes of persistent and long-standing persistent atrial fibrillation (PsAF and L-PsAF) ablation guided by remote magnetic navigation (RMN), and to detect factors predicting acute restoration of sinus rhythm (SR) by ablation with RMN. A total of 313 patients (275 male, age 59 ± 9.5 years) with PsAF (187/313) or L-PsAF (126/313) undergoing ablation using RMN were included. Patients' disease history, pulmonary venous anatomy, left atrial (LA) volume, procedure time, mapping plus ablation time, radiofrequency (RF) ablation time, fluoroscopy time, radiation dose, and complications were assessed. Stepwise regression was used to predict which variable could best predict acute restoration from AF to SR by ablation. Compared to PsAF, procedure time and RF ablation time were significantly increased in patients with L-PsAF (P = 0.01 and P < 0.001, respectively). No major complications occurred during the procedures in either PsAF or L-PsAF patients. Fifty five of 313 patients converted directly to SR by ablation. Compared to L-PsAF, the rate of SR restoration was significantly higher in PsAF (21 vs 12%, P = 0.03). Stepwise regression analysis showed LA volume was the primary parameter affecting SR restoration (P = 0.01). The LA volume of patients without direct SR restoration by ablation was 24% greater than that of patients with SR restoration (P < 0.001). Catheter ablation using RMN is a safe and effective method for PsAF and L-PsAF. LA volume could be a predictor of direct restoration of SR from sustaining AF by ablation using RMN.
Optical probes of symmetry breaking in magnetic and superconducting BaFe2(As1-xPx)2
NASA Astrophysics Data System (ADS)
Orenstein, Joseph
The discovery of iron pnictide superconductors has opened promising new directions in the effort to fully understand the phenomenon of high-Tc, with a focus on the connections between superconductivity, magnetism, and electronic nematicity. The BaFe2(As1-xPx)2 (P:Ba122) system in particular has received attention because isovalent substitution of As for P generates less disorder than doping on the Fe site. The phase diagram of P:Ba122 is characterized by a line of simultaneous antiferromagnetic (AF) and tetragonal-to-orthorhombic transitions, Ts (x) , that penetrates the superconducting dome at x =0.28, just below optimal doping (xopt = 0.30). In this work, we use spatially-resolved optical polarimetry and photomodulated reflectance to detect linear birefringence and therefore breaking of 4-fold rotational (C4) symmetry. In underdoped (x<0.28) samples, birefringence appears at T>Tsand grows continuously with decreasing T . The birefringence is unidirectional in a large (300 μm x300 μm) field of view, suggesting that C4 breaking in this range of T is caused by residual strain that couples to a diverging nematic susceptibility. Birefringence maps just below Ts (x) show the appearance of domains, indicating the onset of spontaneous symmetry breaking to an AF ground state. Surprisingly, in samples with x>0.28, in which the low T phase is superconducting/ tetragonal rather than AF/orthorhombic, C4 breaking is observed as well, with an abrupt onset and domain formation at 55 K. We tentatively associate these features with a transition to an AF phase induced by residual strain, as previously proposed [H.-H. Kuo et al. Phys. Rev. B86, 134507 (2012)] to account for structure in resistivity vs. T. Time-resolved photomodulation allow us to follow the amplitude of the AF order with time following pulsed photoexcitation. Below Tc the AF order at first weakens , but then strengthens in response to the photoinduced weakening of superconductivity. This complex time evolution is accounted for quantitatively by a model based on the coexistence and competition of AF and superconducting order. We gratefully acknowledge support by the U.S. Department of Energy, Office of Science, Materials Sciences and Engineering Division, and the Gordon and Betty Moore Foundation's EPiQS Initiative through Grant GBMF4537.
Jiang Md, Chen-Yang; Jiang Ms, Ru-Hong
2014-01-01
Atrial fibrillation (AF) is one of the most common cardiac arrhythmias. Catheter ablation has proven more effective than antiarrhythmic drugs in preventing clinical recurrence of AF, however long-term outcome remains unsatisfactory. Ablation strategies have evolved based on progress in mechanistic understanding, and technologies have advanced continuously. This article reviews current mechanistic concepts and technological advancements in AF treatment, and summarizes their impact on improvement of AF ablation outcome.
Acute cardiovascular effects of diltiazem in anesthetized dogs with induced atrial fibrillation.
Miyamoto, M; Nishijima, Y; Nakayama, T; Hamlin, R L
2001-01-01
Atrial fibrillation (AF) is one of the most important arrhythmias of dogs. In a previous study, we determined the dosage of intravenously administered diltiazem necessary to reduce ventricular response (VR), cardiac output (CO), and mean systemic arterial pressure (P(Ao)) to values similar to those observed during sinus rhythm (SR) before induction of AF. The present study was conducted to establish an acute, effective dosage of diltiazem given PO. AF was produced by rapid atrial pacing in healthy, anesthetized Beagle Hounds. Dogs were instrumented to record hemodynamic and electrophysiological parameters. Four dogs were given 2.5 mg/kg diltiazem, and another 4 dogs were given 5 mg/kg diltiazem by stomach tube, whereas 4 other dogs received vehicle in equivalent volumes. Plasma concentrations of diltiazem were measured at various intervals after dosing. A dosage of 5 mg/kg diltiazem produced plasma concentrations of 32-100 ng/mL 3 hours after administration, concentrations within the published effective range for dogs with naturally occurring AF. Between 2 and 3 hours after this dosage, the rate pressure product (RPP) and an index of left ventricular efficiency returned to values similar to those observed during SR. Thus, we believe that diltiazem at anorally administered dosages of 5 mg/kg should be considered to produce therapeutic blood concentrations and favorable hemodynamic effects in dogs with naturally occurring AF. These data must be extrapolated with caution to dogs with long-standing AF produced by natural causes.
Yang, Qiong; Churilov, Leonid; Fan, Dongsheng; Davis, Stephen; Yan, Bernard
2017-08-15
Prevalence of atrial fibrillation (AF) has quadrupled in the past 50years in the general population. However, there is uncertainty regarding prevalence of AF over time in ischemic stroke patients given the aging population and enhanced surveillance of AF. We aimed to explore the changing prevalence of AF as well as other risk factors, stroke subtypes, investigations and pre-stroke medications among ischemic stroke and transient ischemic attack (TIA) patients. We performed a retrospective analysis of data from a prospective database of consecutive patients with acute ischemic stroke and TIA from 2004 to 2015. Trends in risk factors and other variables year by year were analyzed using logistic regression or median regression. Among 6275 patients (median age [interquartile range] 74 [62-82] years, 56% males), the prevalence of AF increased 1.4 times over 12years (from 23.3% to 32.7%, P<0.001). The increase in the prevalence of AF remained significant after adjustment for age and the use of Holter monitoring. There was also a significant increase in prevalence of hypertension (67.4% to 77.3%), structural heart disease (9.8% to 10.5%), and previous TIA (10.9% to 13.7%) and a significant decrease in prevalence of dyslipidemia (71.8% to 49.4%). There was a 1.4 times increase in the prevalence of AF among consecutive ischemic stroke and TIA patients in the past 12years in a hospital-based registry. More active screening of the general population for AF may be warranted in order to decrease the overall stroke burden. Copyright © 2017 Elsevier B.V. All rights reserved.
Gul, Enes E; Pal, Raveen; Caldwell, Jane; Boles, Usama; Hopman, Wilma; Glover, Benedict; Michael, Kevin A; Redfearn, Damian; Simpson, Chris; Abdollah, Hoshiar; Baranchuk, Adrian
2017-07-01
Interatrial block (IAB) is a strong predictor of recurrence of atrial fibrillation (AF). IAB is a conduction delay through the Bachman region, which is located in the upper region of the interatrial space. During IAB, the impulse travels from the right atrium to the interatrial septum (IAS) and coronary sinus to finally reach the left atrium in a caudocranial direction. No relation between the presence of IAB and IAS thickness has been established yet. To determine whether a correlation exists between the degree of IAB and the thickness of the IAS and to determine whether IAS thickness predicts AF recurrence. Sixty-two patients with diagnosis of paroxysmal AF undergoing catheter ablation were enrolled. IAB was defined as P-wave duration ≥120 ms. IAS thickness was measured by cardiac computed tomography. Among 62 patients with paroxysmal AF, 45 patients (72%) were diagnosed with IAB. Advanced IAB was diagnosed in 24 patients (39%). Forty-seven patients were male. During a mean follow-up period of 49.8 ± 22 months (range 12-60 months), 32 patients (51%) developed AF recurrence. IAS thickness was similar in patients with and without IAB (4.5 ± 2.0 mm vs. 4.0 ± 1.4 mm; p = .45) and did not predict AF. Left atrial size was significantly enlarged in patients with IAB (40.9 ± 5.7 mm vs. 37.2 ± 4.0 mm; p = .03). Advanced IAB predicted AF recurrence after the ablation (OR: 3.34, CI: 1.12-9.93; p = .03). IAS thickness was not significantly correlated to IAB and did not predict AF recurrence. IAB as previously demonstrated was an independent predictor of AF recurrence. © 2016 Wiley Periodicals, Inc.
Bartoli-Abdou, John K; Patel, Jignesh P; Crawshaw, Jacob; Vadher, Bipin; Brown, Alison; Roberts, Lara N; Patel, Raj K; Arya, Roopen; Auyeung, Vivian
2018-02-01
Current UK and European guidelines recommend anticoagulated patients prescribed warfarin with time in therapeutic range (TTR) <65% be considered for DOAC therapy. There has been considerable concern that adherence with DOACs may be poor compared with warfarin. Little is known about the patient experience of switching from warfarin to DOAC and how patients manage their DOAC long term. Our aim was to conduct focus groups exploring patient's previous experiences with warfarin, their current experience with DOACs, their adherence to DOACs and the long-term service provision they envisage. Patients enrolled on the Switching Study who had been switched from warfarin to a DOAC >1year previously were invited to participate in focus groups. Two focus groups for atrial fibrillation (AF) and two for secondary prevention of venous thromboembolism (VTE) patients were held at anticoagulation clinics in South London, UK. Data was analysed using framework analysis to extract dominant themes. Five VTE patients and 15 AF patients attended the focus groups. Dominant themes that emerged were: indication specific anticoagulation prioritisation, warfarin as a necessary inconvenience, DOACs as the anticoagulant of choice, concerns regarding DOAC monitoring, high adherence to DOACs and desire for long-term access to specialist anticoagulation services. VTE patients prioritised anticoagulation over other therapies whereas AF patients did not. All participants reported high levels of adherence to DOACs. Patients derived confidence from long-term management in specialist anticoagulation clinics stating a preference to be managed in such a service. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Long-Range Operational Military Forecasts for Iraq
2007-03-01
http://www.afccc.af.mil 5 March 2007] .................................................. 4 Figure 3. Primary storm tracks for: (a) June, July, August...Laboratory ETC extratropical cyclone FA forecast accuracy FAR false alarm rate HSS Heidke skill score IO Indian Ocean IOZM Indian Ocean Zonal...precipitation is associated with transient extratropical cyclones (ETCs). Most of Iraq’s terrain is relatively flat with little change in elevation
Pachón-M, José Carlos; Pachón-M, Enrique I; Santillana P, Tomas G; Lobo, Tasso Julio; Pachón, Carlos Thiene C; Pachón-M, Juán Carlos; Albornoz V, Remy Nelson; Zerpa A, Juán Carlos; Ortencio, Felipe; Arruda, Mauricio
2017-01-01
Catheter ablation of long-standing persistent AF (LSAF) remains challenging. Since AF-Nest (AFN) description, we have observed that a stable, protected, fast source firing, namely "Background Tachycardia"(BT), could be hidden beneath the chaotic AF. Following pulmonary vein isolation (PVI)+AFN ablation one or more BT may arise or be induced in 30-40% of patients, which could be the culprit forAF maintenance and ablation recurrences. We studied 114 patients, from 322 sequential LSAF regular ablations, having spontaneous or induced residual BT after EGM-guided PVI+AFN ablation of LSAF; 55.6±11y/o, 97males (85.1%), EF=65.5±8%, LA=42.8±6.7mm. Macroreentrant tachycardias were excluded. Pre-ablationAF 12-leads ECG Digital processing(DP) and spectral analysis(SA) was performed searching for BT before AF ablation and its correlation with BT during ablation.After PVI, 38.1±9 AFN sites/patient and 135 sustained BTs (1-3, 1.2±0.5/patient) were ablated. BT cycle length(CL) was 246.3±37.3ms. In 79 patients presenting suitable DP for SA, the BT-CL was 241.6±34.3ms with intra procedure BT-CL correlation r=0.83/p<0.01. Following BT ablation, AF could not be induced. During FU of 13→60 months(22.8±12m), AF freedom for BT RF(+) vs. BT RF(-) groups were 77.9% vs. 56.4% (p=0.009), respectively. There was no significant complication. BT ablation following PVI and AFN ablation improved long-term outcomes ofLSAF ablation. BT is likely due to sustained microreentry, protected during AF by entry block. BT can be suspected by spectral analysis of the pre-ablation ECG and is likely one important AF perpetuator by causing electrical resonance of the AFN. This ablation strategy warrants randomized, multicenter investigation.
Tedrow, Usha B; Conen, David; Ridker, Paul M; Cook, Nancy R; Koplan, Bruce A; Manson, JoAnn E; Buring, Julie E; Albert, Christine M
2010-01-01
Objectives To characterize the relationship between changes in body mass index (BMI) and incident atrial fibrillation (AF) in a large cohort of women. Background Obesity and AF are increasing public health problems. The importance of dynamic obesity-associated AF risk is uncertain, and mediators are not well characterized. Methods Cases of AF were confirmed by medical record review in 34,309 participants in the Women’s Health Study. Baseline and updated measures of BMI were obtained from periodic questionnaires. Results Over 12.9 +/− 1.9 years of follow-up, 834 AF events were confirmed. BMI was linearly associated with AF risk, with a 4.7% (95% CI 3.4, 6.1, p<0.0001) increase in risk with each kg/m2. Adjustment for inflammatory markers minimally attenuated this risk. When updated measures of BMI were utilized to estimate dynamic risk, overweight (HR 1.22 95%CI 1.02, 1.45, p=0.03) and obesity (HR 1.65 95%CI 1.36, 2.00, p<0.0001) were associated with adjusted short term elevations in AF risk. Participants becoming obese during the first 60 months had a 41% adjusted increase in risk of developing AF (p=0.02) compared to those maintaining BMI <30 kg/m2. The prevalence of overweight and obesity increased over time. The adjusted proportion of incident AF attributable to short term elevations in BMI was substantial (18.3%). Conclusions In this population of apparently healthy women, BMI was associated with short and long term elevations in AF risk, accounting for a large proportion of incident AF independent of traditional risk factors. A strategy of weight control may reduce the increasing incidence of AF. PMID:20488302
Targeting Stable Rotors to Treat Atrial Fibrillation.
Narayan, Sanjiv M; Krummen, David E
2012-09-01
Therapy for atrial fibrillation (AF) remains suboptimal, in large part because its mechanisms are unclear. While pulmonary vein ectopy may trigger AF, it remains uncertain how AF, once triggered, is actually sustained. Recent discoveries show that human AF is maintained by a small number of rotors or focal sources. AF sources are widely distributed in patient-specific locations, often remote from pulmonary veins and in the right atrium and stable for prolonged periods of time. In a multicentre experience, brief targeted ablation at sources (focal impulse and rotor modulation [FIRM]) terminated AF predominantly to sinus rhythm prior to pulmonary vein isolation and eliminated AF on rigorous followup. This review summarises the evidence for stable rotors and focal sources of human AF and their clinical role as ablation targets to eliminate paroxysmal, persistent and long-standing persistent AF.
Pre-clinical laboratory evaluation of the new 'AF' arterial line filter range.
Yarham, Gemma; Mulholland, John
2010-07-01
The presence of emboli was recognised relatively early in the history of open heart surgery. The emboli produced during cardiopulmonary bypass have the predisposition to distribute into, and ultimately obstruct, microvessels of all tissues. The Sorin Group has recently developed a new range of arterial line filters. Before the Sorin AF range of filters was released for pre-launch clinical trials, our group performed in vitro laboratory testing of the AF range against a selection of commercially available filters on the global market. The Sorin AF620 and AF640 demonstrate both the smallest prime volume and smallest surface contact area (92ml and 290 cm(2), respectively).The results of the GME Handling Efficiency experiments ranged by 39.6%, from 95.9% to 56.3%. In terms of an air bolus handling, the results of the Limit Bolus experiment ranged by 97 ml, from 147.5 ml down to 50 ml. The pressure drop across all the filters was measured under steady state experimental conditions. All of the above investigations were considered against surface area and prime volume. It is clear from the results that some commercially available arterial line filters perform better than others, not only in overall performance, but also with regard to individual characteristics. Evaluating arterial line filters for hospital-specific use has to balance pressure drop, surface area, micro air handling, prime volume and gross air handling; all points need to be considered. In the AF620 and AF640, Sorin boast that they are the two smallest prime and smallest surface area filters commercially available on the global market. The Sorin AF filter range performs well in all of the areas we investigated and will be a competitive option for centres, irrespective of which characteristics they use to evaluate and select their arterial line filter.
State-of-the-art and emerging technologies for atrial fibrillation ablation.
Dewire, Jane; Calkins, Hugh
2010-03-01
Catheter ablation is an important treatment modality for patients with atrial fibrillation (AF). Although the superiority of catheter ablation over antiarrhythmic drug therapy has been demonstrated in middle-aged patients with paroxysmal AF, the role the procedure in other patient subgroups-particularly those with long-standing persistent AF-has not been well defined. Furthermore, although AF ablation can be performed with reasonable efficacy and safety by experienced operators, long-term success rates for single procedures are suboptimal. Fortunately, extensive ongoing research will improve our understanding of the mechanisms of AF, and considerable funds are being invested in developing new ablation technologies to improve patient outcomes. These technologies include ablation catheters designed to electrically isolate the pulmonary veins with improved safety, efficacy, and speed, catheters designed to deliver radiofrequency energy with improved precision, robotic systems to address the technological demands of the procedure, improved imaging and electrical mapping systems, and MRI-guided ablation strategies. The tools, technologies, and techniques that will ultimately stand the test of time and become the standard approach to AF ablation in the future remain unclear. However, technological advances are sure to result in the necessary improvements in the safety and efficacy of AF ablation procedures.
Atrioventricular node functional remodeling induced by atrial fibrillation.
Zhang, Youhua; Mazgalev, Todor N
2012-09-01
The atrioventricular node (AVN) plays a vital role in determining the ventricular rate during atrial fibrillation (AF). AF results in profound electrophysiological and structural remodeling in the atria as well as the sinus node. However, it is unknown whether AVN undergoes remodeling during AF. To determine whether AVN undergoes functional remodeling during AF. AVN conduction properties were studied in vitro in 9 rabbits with AF and 10 normal controls. A previously validated index of AVN dual-pathway electrophysiology, His-electrogram alternans, was used to monitor fast-pathway or slow-pathway (SP) AVN conduction in these experiments. AVN conduction properties were further studied in vivo in 7 dogs with chronic AF and 8 controls. Compared with the control rabbits, the rabbits with AF had a longer AVN conduction time (83 ± 16 ms vs 68 ± 7 ms; P <.01), longer AVN effective refractory period (141 ± 27 ms vs 100 ± 9 ms; P <.01), an earlier transition from fast-pathway to SP conduction (at a longer prematurity, 249 ± 60 ms vs 171 ± 24 ms; P <.01), and a slower ventricular rate during simulated AF (RR interval 249 ± 42 ms vs 202 ± 12 ms; P <.01). Notably, a larger proportion of conducted beats utilized the SP in AF preparations (92% ± 12% vs 63% ± 32%; P <.05). Long-term AF in dogs resulted in a longer atrioventricular conduction time and AVN effective refractory period and a slower ventricular rate during AF compared with the controls. Pronounced AVN functional electrophysiological remodeling occurs after long-term AF, which could lead to a spontaneous slowing of the ventricular rate. Furthermore, the SP dominance during AF underscores the effectiveness of its modification by ablation for ventricular rate control during AF. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Giambelluca, Thomas W.; Loague, Keith; Green, Richard E.; Nullet, Michael A.
1996-06-01
In this paper, uncertainty in recharge estimates is investigated relative to its impact on assessments of groundwater contamination vulnerability using a relatively simple pesticide mobility index, attenuation factor (AF). We employ a combination of first-order uncertainty analysis (FOUA) and sensitivity analysis to investigate recharge uncertainties for agricultural land on the island of O'ahu, Hawai'i, that is currently, or has been in the past, under sugarcane or pineapple cultivation. Uncertainty in recharge due to recharge component uncertainties is 49% of the mean for sugarcane and 58% of the mean for pineapple. The components contributing the largest amounts of uncertainty to the recharge estimate are irrigation in the case of sugarcane and precipitation in the case of pineapple. For a suite of pesticides formerly or currently used in the region, the contribution to AF uncertainty of recharge uncertainty was compared with the contributions of other AF components: retardation factor (RF), a measure of the effects of sorption; soil-water content at field capacity (ΘFC); and pesticide half-life (t1/2). Depending upon the pesticide, the contribution of recharge to uncertainty ranks second or third among the four AF components tested. The natural temporal variability of recharge is another source of uncertainty in AF, because the index is calculated using the time-averaged recharge rate. Relative to the mean, recharge variability is 10%, 44%, and 176% for the annual, monthly, and daily time scales, respectively, under sugarcane, and 31%, 112%, and 344%, respectively, under pineapple. In general, uncertainty in AF associated with temporal variability in recharge at all time scales exceeds AF. For chemicals such as atrazine or diuron under sugarcane, and atrazine or bromacil under pineapple, the range of AF uncertainty due to temporal variability in recharge encompasses significantly higher levels of leaching potential at some locations than that indicated by the AF estimate.
von Schéele, Birgitta; Fernandez, Maria; Hogue, Susan Lynn; Kwong, Winghan Jacqueline
2013-05-01
To summarize the available evidence on the issues in health economics related to oral anticoagulation for stroke prevention in atrial fibrillation (AF) in the US. A literature review was performed using PubMed, EMBASE, Cochrane Library, and International Pharmaceutical Abstracts, as well as the websites of professional organizations. The search was conducted according to a prespecified protocol, limiting articles to those published in English from 2001 to October 2012 and focused on the economics associated with AF and AF-related stroke in the US. Data from 27 studies were extracted and included in the review. Strokes in patients with AF are more debilitating and have higher recurrence rates and mortality compared with strokes unrelated to AF. However, data describing the long-term cost of AF-related stroke and stroke subtypes remain limited. The costs of major gastrointestinal (GI) bleeding and intracranial bleeding related to warfarin are significant, whereas the costs of the more frequent minor GI bleeding are relatively low. Overall, the cost-effectiveness of warfarin versus aspirin or no treatment in patients with at least 1 risk factor for stroke is well established. Economic evaluations based on results from randomized controlled clinical trials generally found that new anticoagulants were a cost-effective alternative to warfarin for stroke prevention in AF. However, these cost-effectiveness results are highly sensitive to how well optimal international normalized ratio control is maintained (within target of 2.0-3.0) for warfarin and the time horizon used for analysis. Time in therapeutic range for warfarin in routine clinical practice was lower than in clinical trials, as shown by previous studies. This review identified several areas of uncertainty regarding the economic benefit of anticoagulants. The generalizability of cost-effectiveness results of anticoagulant therapy in AF based on clinical trial data must be confirmed by comparative effectiveness research conducted in the real-world setting.
Lau, Chu-Pak; Tachapong, Ngarmukos; Wang, Chun-Chieh; Wang, Jing-Feng; Abe, Haruhiko; Kong, Chi-Woon; Liew, Reginald; Shin, Dong-Gu; Padeletti, Luigi; Kim, You-Ho; Omar, Razali; Jirarojanakorn, Kreingkrai; Kim, Yoon-Nyun; Chen, Mien-Cheng; Sriratanasathavorn, Charn; Munawar, Muhammad; Kam, Ruth; Chen, Jan-Yow; Cho, Yong-Keun; Li, Yi-Gang; Wu, Shu-Lin; Bailleul, Christophe; Tse, Hung-Fat
2013-08-13
Atrial-based pacing is associated with lower risk of atrial fibrillation (AF) in sick sinus syndrome compared with ventricular pacing; nevertheless, the impact of site and rate of atrial pacing on progression of AF remains unclear. We evaluated whether long-term atrial pacing at the right atrial (RA) appendage versus the low RA septum with (ON) or without (OFF) a continuous atrial overdrive pacing algorithm can prevent the development of persistent AF. We randomized 385 patients with paroxysmal AF and sick sinus syndrome in whom a pacemaker was indicated to pacing at RA appendage ON (n=98), RA appendage OFF (n=99), RA septum ON (n=92), or RA septum OFF (n=96). The primary outcome was the occurrence of persistent AF (AF documented at least 7 days apart or need for cardioversion). Demographic data were homogeneous across both pacing site (RA appendage/RA septum) and atrial overdrive pacing (ON/OFF). After a mean follow-up of 3.1 years, persistent AF occurred in 99 patients (25.8%; annual rate of persistent AF, 8.3%). Alternative site pacing at the RA septum versus conventional RA appendage (hazard ratio=1.18; 95% confidence interval, 0.79-1.75; P=0.65) or continuous atrial overdrive pacing ON versus OFF (hazard ratio=1.17; 95% confidence interval, 0.79-1.74; P=0.69) did not prevent the development of persistent AF. In patients with paroxysmal AF and sick sinus syndrome requiring pacemaker implantation, an alternative atrial pacing site at the RA septum or continuous atrial overdrive pacing did not prevent the development of persistent AF. URL: http://www.clinicaltrials.gov. UNIQUE IDENTIFIER: NCT00419640.
Schregel, Katharina; Karch, André; Weber-Krueger, Mark; Stahrenberg, Raoul; Gröschel, Klaus; Knauth, Michael; Psychogios, Marios-Nikos; Wachter, Rolf; Liman, Jan
2017-01-01
Background. Atrial fibrillation (AF) is an important cause of embolic stroke of undetermined source (ESUS). Imaging-patterns like multiple infarcts, simultaneous involvement of different circulations, infarcts of different ages, and isolated cortical infarcts are likely to indicate cardioembolic stroke. The aim of our study was to evaluate the association between embolic stroke patterns, ESUS, and the new diagnosis of AF. Methods. Stroke etiology and imaging characteristics from patients included in the Find-AF study were obtained. Embolic stroke patterns in CT- or MR-imaging were correlated with the diagnosis of ESUS as well as the short- (on baseline ECG and during 7-day Holter) and long-term (12-month follow-up) diagnosis of AF. Results. From 281 patients included in the Find-AF study, 127 (45.2%) patients with ischemic lesions detected in CT or MRI were included. 26 (20.5%) of these patients had ESUS. At least one embolic stroke pattern was detected in 67 (52.7%) patients. Embolic stroke patterns were not associated with ESUS (OR 1.57, 0.65–3.79, p = 0.317), the short-term (OR 0.64, 0.26–1.58, p = 0.327) or long-term diagnosis of AF (OR 0.72, 0.31–1.68, p = 0.448). Conclusions. This secondary data analysis of the Find-AF study could not provide evidence for an association between embolic stroke patterns, ESUS, and the new diagnosis of AF. PMID:28536667
Maier, Ilko L; Schregel, Katharina; Karch, André; Weber-Krueger, Mark; Mikolajczyk, Rafael T; Stahrenberg, Raoul; Gröschel, Klaus; Bähr, Mathias; Knauth, Michael; Psychogios, Marios-Nikos; Wachter, Rolf; Liman, Jan
2017-01-01
Background . Atrial fibrillation (AF) is an important cause of embolic stroke of undetermined source (ESUS). Imaging-patterns like multiple infarcts, simultaneous involvement of different circulations, infarcts of different ages, and isolated cortical infarcts are likely to indicate cardioembolic stroke. The aim of our study was to evaluate the association between embolic stroke patterns, ESUS, and the new diagnosis of AF. Methods . Stroke etiology and imaging characteristics from patients included in the Find-AF study were obtained. Embolic stroke patterns in CT- or MR-imaging were correlated with the diagnosis of ESUS as well as the short- (on baseline ECG and during 7-day Holter) and long-term (12-month follow-up) diagnosis of AF. Results . From 281 patients included in the Find-AF study, 127 (45.2%) patients with ischemic lesions detected in CT or MRI were included. 26 (20.5%) of these patients had ESUS. At least one embolic stroke pattern was detected in 67 (52.7%) patients. Embolic stroke patterns were not associated with ESUS (OR 1.57, 0.65-3.79, p = 0.317), the short-term (OR 0.64, 0.26-1.58, p = 0.327) or long-term diagnosis of AF (OR 0.72, 0.31-1.68, p = 0.448). Conclusions . This secondary data analysis of the Find-AF study could not provide evidence for an association between embolic stroke patterns, ESUS, and the new diagnosis of AF.
Magnetic viscosity phenomena in exchange coupled CoFe /MnIr bilayers
NASA Astrophysics Data System (ADS)
Kim, Dong Young; Kim, C. O.; Tsunoda, M.; Yamaguchi, M.; Yabugami, S.; Takahashi, M.
2007-05-01
The complex permeability spectra were measured in the low (10Hz-1MHz) and microwave (100MHz-9GHz) frequency ranges in CoFe /MnIr bilayers. The low frequency permeability spectra showed the magnetic viscosity effect below the critical antiferromagnet thickness (tcAF), but not at tAF
Graves, Kevin G; May, Heidi T; Jacobs, Victoria; Bair, Tami L; Stevens, Scott M; Woller, Scott C; Crandall, Brian G; Cutler, Michael J; Day, John D; Mallender, Charles; Osborn, Jeffrey S; Peter Weiss, J; Jared Bunch, T
2017-06-01
Patients with atrial fibrillation (AF) are at higher risk for developing dementia. Warfarin is a common therapy for the prevention of thromboembolism in AF, valve replacement, and thrombosis patients. The extent to which AF itself increases dementia risk remains unknown. A total 6030 patients with no history of dementia and chronically anticoagulated with warfarin were studied. Warfarin management was provided through a Clinical Pharmacy Anticoagulation Service. Patients were stratified by warfarin indication of AF (n=3015) and non-AF (n=3015) and matched by propensity score (±0.01). Patients were stratified by the congestive heart failure, hypertension, age >75 years, diabetes, stroke (CHADS 2 ) score calculated at the time of warfarin initiation and followed for incident dementia. The average age of the AF cohort was 69.3±11.2 years, and 52.7% were male; average age of non-AF cohort was 69.3±10.9 years, and 51.5% were male. Increasing CHADS 2 score was associated with increased dementia incidence, P trend=.004. When stratified by warfarin indication, AF patients had an increased risk of dementia incidence. After multivariable adjustment, AF patients continued to display a significantly increased risk of dementia when compared with non-AF patients across all CHADS 2 scores strata. In patients receiving long-term warfarin therapy, dementia risk increased with increasing CHADS 2 scores. However, the presence of AF was associated with higher rates of dementia across all CHADS 2 score strata. These data suggest that AF contributes to the risk of dementia and that this risk is not solely attributable to anticoagulant use. Dementia may be an end manifestation of a systemic disease state, and AF likely contributes to its progression. Copyright © 2017 Elsevier Inc. All rights reserved.
Baumgartner, Christine; da Costa, Bruno R; Collet, Tinh-Hai; Feller, Martin; Floriani, Carmen; Bauer, Douglas C; Cappola, Anne R; Heckbert, Susan R; Ceresini, Graziano; Gussekloo, Jacobijn; den Elzen, Wendy P J; Peeters, Robin P; Luben, Robert; Völzke, Henry; Dörr, Marcus; Walsh, John P; Bremner, Alexandra; Iacoviello, Massimo; Macfarlane, Peter; Heeringa, Jan; Stott, David J; Westendorp, Rudi G J; Khaw, Kay-Tee; Magnani, Jared W; Aujesky, Drahomir; Rodondi, Nicolas
2017-11-28
Atrial fibrillation (AF) is a highly prevalent disorder leading to heart failure, stroke, and death. Enhanced understanding of modifiable risk factors may yield opportunities for prevention. The risk of AF is increased in subclinical hyperthyroidism, but it is uncertain whether variations in thyroid function within the normal range or subclinical hypothyroidism are also associated with AF. We conducted a systematic review and obtained individual participant data from prospective cohort studies that measured thyroid function at baseline and assessed incident AF. Studies were identified from MEDLINE and EMBASE databases from inception to July 27, 2016. The euthyroid state was defined as thyroid-stimulating hormone (TSH) 0.45 to 4.49 mIU/L, and subclinical hypothyroidism as TSH 4.5 to 19.9 mIU/L with free thyroxine (fT4) levels within reference range. The association of TSH levels in the euthyroid and subclinical hypothyroid range with incident AF was examined by using Cox proportional hazards models. In euthyroid participants, we additionally examined the association between fT4 levels and incident AF. Of 30 085 participants from 11 cohorts (278 955 person-years of follow-up), 1958 (6.5%) had subclinical hypothyroidism and 2574 individuals (8.6%) developed AF during follow-up. TSH at baseline was not significantly associated with incident AF in euthyroid participants or those with subclinical hypothyroidism. Higher fT4 levels at baseline in euthyroid individuals were associated with increased AF risk in age- and sex-adjusted analyses (hazard ratio, 1.45; 95% confidence interval, 1.26-1.66, for the highest quartile versus the lowest quartile of fT4; P for trend ≤0.001 across quartiles). Estimates did not substantially differ after further adjustment for preexisting cardiovascular disease. In euthyroid individuals, higher circulating fT4 levels, but not TSH levels, are associated with increased risk of incident AF. © 2017 American Heart Association, Inc.
Fluctuations of healthy and unhealthy heartbeat intervals
NASA Astrophysics Data System (ADS)
Lan, Boon Leong; Toda, Mikito
2013-04-01
We show that the RR-interval fluctuations, defined as the difference between successive natural-logarithm of the RR interval, for healthy, congestive-heart-failure (CHF) and atrial-fibrillation (AF) subjects are well modeled by non-Gaussian stable distributions. Our results suggest that healthy or unhealthy RR-interval fluctuation can generally be modeled as a sum of a large number of independent physiological effects which are identically distributed with infinite variance. Furthermore, we show for the first time that one indicator —the scale parameter of the stable distribution— is sufficient to robustly distinguish the three groups of subjects. The scale parameters for healthy subjects are smaller than those for AF subjects but larger than those for CHF subjects —this ordering suggests that the scale parameter could be used to objectively quantify the severity of CHF and AF over time and also serve as an early warning signal for a healthy person when it approaches either boundary of the healthy range.
Ikegami, Yukinori; Tanimoto, Kojiro; Inagawa, Kohei; Shiraishi, Yasuyuki; Fuse, Jun; Sakamoto, Munehisa; Momiyama, Yukihiko; Takatsuki, Seiji
2017-12-25
Intracardiac echocardiography (ICE) and cardiac computed tomography (CCT), in addition to standard transesophageal echocardiography (TEE), have been used to identify left atrial (LA) thrombi prior to ablation for atrial fibrillation (AF). The clinical advantages of this, however, remain unclear. This study therefore investigated the advantages of additional pre-procedural LA appendage (LAA) thrombus evaluation using ICE and the clinical value of CCT in persistent and long-standing persistent AF.Methods and Results:We analyzed data from 108 consecutive patients with persistent and long-standing persistent AF who were scheduled to undergo AF ablation. TEE was performed within 24 h prior to ablation. ICE was performed for 97 patients in whom a thrombus was not detected on TEE. CCT was performed in 95 patients. Thrombus or sludge was detected on TEE in 11 patients (10.3%), for whom ablation was cancelled. Four additional patients were diagnosed with LAA thrombus on ICE. When TEE and ICE were used as the reference for thrombus detection, the sensitivity, specificity, positive predictive value, and negative predictive value of CCT for identifying contrast defects in the LAA were 100%, 81.0%, 40.7%, and 100%, respectively. ICE combined with TEE increased the detection rate of LAA thrombi in patients with persistent and long-standing persistent AF. Moreover, CCT had high sensitivity and negative predictive value for LAA thrombus detection.
NASA Astrophysics Data System (ADS)
Ohsugi, S.; Tokunaga, Y.; Ishida, K.; Kitaoka, Y.; Azuma, M.; Fujishiro, Y.; Takano, M.
1999-08-01
We report characteristics of impurity-induced staggered polarization (IISP) and antiferromagnetic long-range order (AF-LRO) in the gapped spin-1/2 Heisenberg two-leg ladder compound SrCu2O3 (Sr123). We have carried out comprehensive NMR and NQR investigations on three impurity-doped systems, Sr(Cu1-xMx)2O3 (M=Zn, Ni) with x<=0.02 and Sr1-xLaxCu2O3 with x<=0.03. Either the Zn or Ni impurity that is nonmagnetic depletes a single spin on the ladders, whereas the La impurity is believed to dope electrons onto the ladders. The width of the Lorentzian Cu NMR spectrum increases with the increase in impurity content x and follows the Curie-like temperature (T) dependence as W/T. The W's for the Zn- and Ni-doped samples (M doping) are larger than for the La-doped one (La doping). The NMR spectra were fit by assuming that unpaired spin S0=1/2 induced next to impurity on the rung for the Zn and Ni doping (S0=1/4 for the La doping) creates the staggered spin polarization along the leg, which decreases exponentially from S0. In Sr123, an instantaneous spin-correlation length ξ0 was theoretically predicted as ξ0/a~3-8, where a is the lattice spacing between the Cu sites along the leg. However, a correlation length ξs/a estimated from the IISP along the leg was found to be much longer than ξ0/a in x=0.001 and 0.005. The notable result is that ξs/a that was found to be T independent is scaled to mean distances DAV=1/(2x) between the Zn and Ni impurities and DAV=1/x between the La impurities. When DAV=500 for x=0.001 (Zn doping), ξs/a~50 is estimated. The significantly broadened NQR spectrum has provided unambiguous evidence for the AF-LRO in the Zn and Ni doping (x=0.01 and 0.02). Rather uniform AF moments at the middle Cu sites between the impurities are estimated to be about 0.04μB at 1.4 K along the a axis. By assuming that exponential decay constants of AF moments are equivalent to ξs/a's for the IISP, the size of an AF moment next to the impurity is deduced as SAF~1/4. We propose that these exponential distributions of IISP and AF moments along the two-leg suggest that an interladder interaction is in a weakly coupled quasi-one-dimensional (WC-Q1D) regime. The formula of TN=J0exp(-DAV/(ξs/a)) based on the WC-Q1D model explains TN(exp)=3 K (x=0.01) and 5.8 K (x=0.02) quantitatively and predicts to be as small as TN=0.09 K for x=0.001 using J0=2000 K. On the other hand, there is no evidence of AF-LRO for the La doping (x=0.02 and 0.03) down to 1.4 K, nevertheless their ξs/a's are almost equivalent to those in the Zn and Ni doping (x=0.01 and 0.02). We remark that the Q1D-IISP is dramatically enhanced by the interladder interaction even though so weak, once the impurity breaks up the quantum coherence in the short-range resonating valence bond (RVB) state with the gap. On the one hand, we propose that TN is determined by a strength of the interladder interaction and a size of S0.
Real-time porphyrin detection in plaque and caries: a case study
NASA Astrophysics Data System (ADS)
Timoshchuk, Mari-Alina I.; Ridge, Jeremy S.; Rugg, Amanda L.; Nelson, Leonard Y.; Kim, Amy S.; Seibel, Eric J.
2015-02-01
An ultrathin scanning fiber endoscope, originally developed for cancer diagnosis, was used in a case study to locate plaque and caries. The imaging system incorporated software mitigation of background auto-fluorescence (AF). In conventional fluorescence imaging, varying AF across a tooth surface can mask low-level porphyrin signals. Laser-induced auto-fluorescence signals of dental tissue excited using a 405-nm laser typically produce fluorescence over a wavelength range extending from 440-nm to 750-nm. Anaerobic bacterial metabolism produces various porphyrin species (eg. protoporphyrin IX) that are located in carious enamel, dentin, gingivitis sites, and plaque. In our case study, these porphyrin deposits remained as long as one day after prophylaxis. Imaging the tooth surface using 405-nm excitation and subtracting the natural AF enhances the image contrast of low-level porphyrin deposits, which would otherwise be masked by the high background AF. In a case study, healthy tissues as well as sites of early and advanced caries formations were scanned for visual and quantitative signs of red fluorescence associated with porphyrin species using a background mitigation algorithm. Initial findings show increasing amplitudes of red fluorescence as caries severity increases from early to late stages. Sites of plaque accumulation also displayed red fluorescence similar to that found in carious dental tissue. The use of real-time background mitigation of natural dental AF can enhance the detection of low porphyrin concentrations that are indicators of early stage caries formation.
Im, Sung Il; Park, Dong Hyun; Kim, Bong Joon; Cho, Kyoung Im; Kim, Hyun Su; Heo, Jung Ho
2018-06-01
Identification of precursors of atrial fibrillation (AF) may lead to early detection and prevent associated morbidity and mortality. Atrial premature complexes (APCs) are commonly seen in healthy subjects. However, there was limited data about the clinical and electrocardiographic (ECG) characteristics for prediction of new-onset AF in asymptomatic patients with APCs in the long-term follow up. The Kosin University (No. 2014-02-04) 24-h holter monitoring, echocardiography, ECG database were reviewed from 2008 to 2016 to identify new- onset AF in patients with APCs. We analyzed demographic and clinical features and the nature of the APCs by ECG according to new-onset AF in those patients. Among 652 patients who underwent 24-h holter monitoring, 226 (34.4%) patients had new-onset AF. There was no difference of the baseline characteristics between new-onset AF group and non-AF group. In univariate analysis, hypertension (HTN), renal failure (CRF), high APC burdens, fastest APC running heart rate (HR), minimal HR, left ventricular ejection fraction (LVEF), left atrial volume index, peak mitral flow velocity of the early rapid filling wave and tricuspid regurgitation grade were significantly associated with new-onset AF. In multivariate analysis, higher APCs burden ( P = 0.047), higher fastest APCs running HR ( P = 0.034) and lower minimal HR ( P = 0.025) were independent risk factors for new-onset AF in asymptomatic patients with APCs. Higher APCs burden, higher fastest APCs running HR and lower minimal HR were associated with new-onset AF in asymptomatic patients with APCs in the long-term follow up.
Castellá, Manuel
2018-04-01
For the first time, the European Society of Cardiology and the European Association for Cardio-Thoracic Surgery have joined forces to develop consensus guidelines for the management of atrial fibrillation (AF). One of the main issues is the integrated care of patients with AF, with emphasis on multidisciplinary teams of general physicians, cardiologists, stroke specialists and surgeons, together with the patient's involvement for better management of AF. These guidelines also help in the detection of risk factors and concomitant cardiovascular diseases, stroke prevention therapies, including anticoagulation and antiplatelet therapies after acute coronary episodes, major haemorrhages or strokes. In the field of ablation, surgery plays an important role as concomitant with other surgical procedures, and it should be considered in symptomatic patients with the highest level of evidence. Asymptomatic patients with mitral insufficiency should also be considered for combined mitral and AF surgery if they have new-onset AF. In patients with stand-alone AF, recommendations for minimally invasive ablation have an increased level of recommendation and should be considered as the same level as catheter ablation in patients with persistent or long-standing persistent AF or with paroxysmal AF who fail catheter ablation. Surgical occlusion or exclusion of the left atrial appendage may be considered for stroke prevention in patients with AF about to have surgery. Nevertheless, not enough is known to avoid long-term anticoagulation in patients at risk of stroke even if the left atrial appendage has been excluded. These Guidelines provide a full spectrum of recommendations on the management of patients with AF including prevention, treatment and complications based on the latest published evidence.
Wongcharoen, Wanwarang; Lin, Yenn-Jiang; Chang, Shih-Lin; Lo, Li-Wei; Hu, Yu-Feng; Chung, Fa-Po; Chong, Eric; Chao, Tze-Fan; Tuan, Ta-Chuan; Chang, Yao-Ting; Lin, Chin-Yu; Liao, Jo-Nan; Lin, Yi-Chun; Chen, Yun-Yu; Chen, Shih-Ann
2015-09-01
Hyperthyroidism is a known reversible cause of atrial fibrillation (AF). However, some patients remain in AF despite restoration of euthyroid status. The purpose of this study was to compare the electrophysiologic characteristics and long-term ablation outcome in AF patients with and without history of hyperthyroidism. The study enrolled 717 consecutive patients with AF who underwent first AF ablation, which involved pulmonary vein (PV) isolation in paroxysmal AF and additional substrate modification in nonparoxysmal AF patients. Eighty-four patients (12%) with hyperthyroidism history were compared to those without. Euthyroid status was achieved for ≥3 months before ablation in hyperthyroid patients. Patients with hyperthyroid history were associated with older age, more female gender, lower mean right atrial voltage, higher number of PV ectopic foci (1.3 ± 0.4 vs 1.0 ± 0.2, P < .01), and higher prevalence of non-PV foci (42% vs 23%, P < .01). Ectopic foci from ligament of Marshall were demonstrated more often in hyperthyroid patients (7.1% vs 1.6%, P < .01) in whom alcohol ablations were required. After propensity score matching for potential covariates, history of hyperthyroidism was an independent predictor of AF recurrence after single procedure (hazard ratio 2.07, 95% confidence interval 1.27-3.38). AF recurrence rates after multiple procedures were not different between patients with and those without hyperthyroid history. Patients with hyperthyroid history had a significantly higher number of PV ectopies and higher prevalence of non-PV ectopic foci compared to euthyroid patients, which resulted in a higher AF recurrence rate after a single procedure. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Long, Rose G; Rotman, Stijn G; Hom, Warren W; Assael, Dylan J; Illien-Jünger, Svenja; Grijpma, Dirk W; Iatridis, James C
2018-02-01
Herniated intervertebral discs (IVDs) are a common cause of back and neck pain. There is an unmet clinical need to seal annulus fibrosus (AF) defects, as discectomy surgeries address acute pain but are complicated by reherniation and recurrent pain. Copolymers of polyethylene glycol with trimethylene carbonate (TMC) and hexamethylene diisocyanate (HDI) end-groups were formulated as AF sealants as the HDI form covalent bonds with native AF tissue. TMC adhesives were evaluated and optimized using the design criteria: stable size, strong adherence to AF tissue, high cytocompatibility, restoration of IVD biomechanics to intact levels following in situ repair, and low extrusion risk. TMC adhesives had high adhesion strength as assessed with a pushout test (150 kPa), and low degradation rates over 3 weeks in vitro. Both TMC adhesives had shear moduli (220 and 490 kPa) similar to, but somewhat higher than, AF tissue. The adhesive with three TMC moieties per branch (TMC3) was selected for additional in situ testing because it best matched AF shear properties. TMC3 restored torsional stiffness, torsional hysteresis area and axial range of motion to intact states. However, in a failure test of compressive deformation under fixed 5 ° flexion, some herniation risk was observed with failure strength of 5.9 MPa compared with 13.5 MPa for intact samples; TMC3 herniated under cyclic organ culture testing. These TMC adhesives performed well during in vitro and in situ testing, but additional optimization to enhance failure strength is required to further this material to advanced screening tests, such as long-term degradation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Kanhayuwa, Lakkhana; Coutts, Robert H. A.
2016-01-01
Novel families of short interspersed nuclear element (SINE) sequences in the human pathogenic fungus Aspergillus fumigatus, clinical isolate Af293, were identified and categorised into tRNA-related and 5S rRNA-related SINEs. Eight predicted tRNA-related SINE families originating from different tRNAs, and nominated as AfuSINE2 sequences, contained target site duplications of short direct repeat sequences (4–14 bp) flanking the elements, an extended tRNA-unrelated region and typical features of RNA polymerase III promoter sequences. The elements ranged in size from 140–493 bp and were present in low copy number in the genome and five out of eight were actively transcribed. One putative tRNAArg-derived sequence, AfuSINE2-1a possessed a unique feature of repeated trinucleotide ACT residues at its 3’-terminus. This element was similar in sequence to the I-4_AO element found in A. oryzae and an I-1_AF long nuclear interspersed element-like sequence identified in A. fumigatus Af293. Families of 5S rRNA-related SINE sequences, nominated as AfuSINE3, were also identified and their 5'-5S rRNA-related regions show 50–65% and 60–75% similarity to respectively A. fumigatus 5S rRNAs and SINE3-1_AO found in A. oryzae. A. fumigatus Af293 contains five copies of AfuSINE3 sequences ranging in size from 259–343 bp and two out of five AfuSINE3 sequences were actively transcribed. Investigations on AfuSINE distribution in the fungal genome revealed that the elements are enriched in pericentromeric and subtelomeric regions and inserted within gene-rich regions. We also demonstrated that some, but not all, AfuSINE sequences are targeted by host RNA silencing mechanisms. Finally, we demonstrated that infection of the fungus with mycoviruses had no apparent effects on SINE activity. PMID:27736869
Kanhayuwa, Lakkhana; Coutts, Robert H A
2016-01-01
Novel families of short interspersed nuclear element (SINE) sequences in the human pathogenic fungus Aspergillus fumigatus, clinical isolate Af293, were identified and categorised into tRNA-related and 5S rRNA-related SINEs. Eight predicted tRNA-related SINE families originating from different tRNAs, and nominated as AfuSINE2 sequences, contained target site duplications of short direct repeat sequences (4-14 bp) flanking the elements, an extended tRNA-unrelated region and typical features of RNA polymerase III promoter sequences. The elements ranged in size from 140-493 bp and were present in low copy number in the genome and five out of eight were actively transcribed. One putative tRNAArg-derived sequence, AfuSINE2-1a possessed a unique feature of repeated trinucleotide ACT residues at its 3'-terminus. This element was similar in sequence to the I-4_AO element found in A. oryzae and an I-1_AF long nuclear interspersed element-like sequence identified in A. fumigatus Af293. Families of 5S rRNA-related SINE sequences, nominated as AfuSINE3, were also identified and their 5'-5S rRNA-related regions show 50-65% and 60-75% similarity to respectively A. fumigatus 5S rRNAs and SINE3-1_AO found in A. oryzae. A. fumigatus Af293 contains five copies of AfuSINE3 sequences ranging in size from 259-343 bp and two out of five AfuSINE3 sequences were actively transcribed. Investigations on AfuSINE distribution in the fungal genome revealed that the elements are enriched in pericentromeric and subtelomeric regions and inserted within gene-rich regions. We also demonstrated that some, but not all, AfuSINE sequences are targeted by host RNA silencing mechanisms. Finally, we demonstrated that infection of the fungus with mycoviruses had no apparent effects on SINE activity.
Atrial Fibrillation During an Exploration Class Mission
NASA Technical Reports Server (NTRS)
Lipset, Mark A.; Lemery, Jay; Polk, J. D.; Hamilton, Douglas R.
2010-01-01
Background: A long-duration exploration class mission is fraught with numerous medical contingency plans. Herein, we explore the challenges of symptomatic atrial fibrillation (AF) occurring during an exploration class mission. The actions and resources required to ameliorate the situation, including the availability of appropriate pharmaceuticals, monitoring devices, treatment modalities, and communication protocols will be investigated. Challenges of Atrial Fibrillation during an Exploration Mission: Numerous etiologies are responsible for the initiation of AF. On Earth, we have the time and medical resources to evaluate and determine the causative situation for most cases of AF and initiate therapy accordingly. During a long-duration exploration class mission resources will be severely restricted. How is one to determine if new onset AF is due to recent myocardial infarction, pulmonary embolism, fluid overload, thyrotoxicosis, cardiac structural abnormalities, or CO poisoning? Which pharmaceutical therapy should be initiated and what potential side effects can be expected? Should anti-coagulation therapy be initiated? How would one monitor the therapeutic treatment of AF in microgravity? What training would medical officers require, and which communication strategies should be developed to enable the best, safest therapeutic options for treatment of AF during a long-duration exploration class mission? Summary: These questions will be investigated with expert opinion on disease elucidation, efficient pharmacology, therapeutic monitoring, telecommunication strategies, and mission cost parameters with emphasis on atrial fibrillation being just one illustration of the tremendous challenges that face a long-duration exploration mission. The limited crew training time, medical hardware, and drugs manifested to deal with such an event predicate that aggressive primary and secondary prevention strategies be developed to protect a multibillion-dollar asset like the International Space Station or a mission to the Moon or Mars. Learning Objectives: The audience will become familiar with the risks and challenges inherent to developing a therapeutic strategy for the treatment of atrial fibrillation during a long-term exploration class mission.
An Evaluation of the Impacts of AF-M315E Propulsion Systems for Varied Mission Applications
NASA Technical Reports Server (NTRS)
Deans, Matthew C.; Oleson, Steven R.; Fittje, James; Colozza, Anthony; Packard, Tom; Gyekenyesi, John; McLean, Christopher H.; Spores, Ronald A.
2015-01-01
The purpose of the AF-M315E COMPASS study is to identify near-term (3-5 years) and long term (5 years +) opportunities for infusion, specifically the thruster and associated component technologies being developed as part of the GPIM project. Develop design reference missions which show the advantages of the AF-M315E green propulsion system. Utilize a combination of past COMPASS designs and selected new designs to demonstrate AF-M315E advantages. Use the COMPASS process to show the puts and takes of using AF-M315E at the integrated system level.
Han, Sang Kuy; Chen, Chao-Wei; Wierwille, Jerry; Chen, Yu; Hsieh, Adam H.
2014-01-01
The defining characteristic of the annulus fibrosus (AF) of the intervertebral disc (IVD) has long been the lamellar structures that consist of highly ordered collagen fibers arranged in alternating oblique angles from one layer to the next. However, a series of recent histologic studies have demonstrated that AF lamellae contain elastin- and type VI collagen-rich secondary “cross-bridge” structures across lamellae. In this study, we use optical coherence tomography (OCT) to elucidate the three-dimensional (3D) morphologies of these translamellar cross-bridge in AF tissues. Mesoscale volumetric images by OCT reveal a highly heterogeneous spatial network and distribution of 3-D translamellar cross-bridges. The results of this study confirm the translamellar cross-bridge is identified as a distinguishable structure, which is laid in the interbundle space of adjacent lamellae and crisscrosses multiple lamellae in the radial direction. In contrast to previously proposed models extrapolated from 2-D sections, results from this current study show that translamellar cross-bridges exist as a complex, interconnected network. We also found much greater variation in lengths of cross-bridges within the interbundle space of lamellae (0.8-1.4 mm from the current study versus 0.3-0.6 mm from 2-D sections). OCT-based 3-D morphology of translamellar cross-bridge provides novel insight into the AF structure. PMID:25564974
Use of warfarin in long-term care: a systematic review
2012-01-01
Background The use of warfarin in older patients requires special consideration because of concerns with comorbidities, interacting medications, and the risk of bleeding. Several studies have suggested that warfarin may be underused or inconsistently prescribed in long-term care (LTC); no published systematic review has evaluated warfarin use for stroke prevention in this setting. This review was conducted to summarize the body of published original research regarding the use of warfarin in the LTC population. Methods A systematic literature search of the PubMed, Cumulative Index to Nursing and Allied Health Literature, and Cochrane Library was conducted from January 1985 to August 2010 to identify studies that reported warfarin use in LTC. Studies were grouped by (1) rates of warfarin use and prescribing patterns, (2) association of resident and institutional characteristics with warfarin prescribing, (3) prescriber attitudes and concerns about warfarin use, (4) warfarin management and monitoring, and (5) warfarin-related adverse events. Summaries of study findings and quality assessments of each study were developed. Results Twenty-two studies met the inclusion criteria for this review. Atrial fibrillation (AF) was the most common indication for warfarin use in LTC and use of warfarin for stroke survivors was common. Rates of warfarin use in AF were low in 5 studies, ranging from 17% to 57%. These usage rates were low even among residents with high stroke risk and low bleeding risk. Scored bleeding risk had no apparent association with warfarin use in AF. In physician surveys, factors associated with not prescribing warfarin included risk of falls, dementia, short life expectancy, and history of bleeding. International normalized ratio was in the target range approximately half of the time. The combined overall rate of warfarin-related adverse events and potential events was 25.5 per 100 resident months on warfarin therapy. Conclusions Among residents with AF, use of warfarin and maintenance of INR levels to prevent stroke appear to be suboptimal. Among prescribers, perceived challenges associated with warfarin therapy often outweigh its benefits. Further research is needed to explicitly consider the appropriate balancing of risks and benefits in this frail patient population. PMID:22480376
Stenner, Philip; Schmidt, Bernhard; Bruder, Herbert; Allmendinger, Thomas; Haberland, Ulrike; Flohr, Thomas; Kachelriess, Marc
2009-12-01
Cardiac CT achieves its high temporal resolution by lowering the scan range from 2pi to pi plus fan angle (partial scan). This, however, introduces CT-value variations, depending on the angular position of the pi range. These partial scan artifacts are of the order of a few HU and prevent the quantitative evaluation of perfusion measurements. The authors present the new algorithm partial scan artifact reduction (PSAR) that corrects a dynamic phase-correlated scan without a priori information. In general, a full scan does not suffer from partial scan artifacts since all projections in [0, 2pi] contribute to the data. To maintain the optimum temporal resolution and the phase correlation, PSAR creates an artificial full scan pn(AF) by projectionwise averaging a set of neighboring partial scans pn(P) from the same perfusion examination (typically N approximately 30 phase-correlated partial scans distributed over 20 s and n = 1, ..., N). Corresponding to the angular range of each partial scan, the authors extract virtual partial scans pn(V) from the artificial full scan pn(AF). A standard reconstruction yields the corresponding images fn(P), fn(AF), and fn(V). Subtracting the virtual partial scan image fn(V) from the artificial full scan image fn(AF) yields an artifact image that can be used to correct the original partial scan image: fn(C) = fn(P) - fn(V) + fn(AF), where fn(C) is the corrected image. The authors evaluated the effects of scattered radiation on the partial scan artifacts using simulated and measured water phantoms and found a strong correlation. The PSAR algorithm has been validated with a simulated semianthropomorphic heart phantom and with measurements of a dynamic biological perfusion phantom. For the stationary phantoms, real full scans have been performed to provide theoretical reference values. The improvement in the root mean square errors between the full and the partial scans with respect to the errors between the full and the corrected scans is up to 54% for the simulations and 90% for the measurements. The phase-correlated data now appear accurate enough for a quantitative analysis of cardiac perfusion.
Charge Order in (TMTTF)2TaF6 by Infrared Spectroscopy
NASA Astrophysics Data System (ADS)
Oka, Yuki; Matsunaga, Noriaki; Nomura, Kazushige; Kawamoto, Atsuhi; Yamamoto, Kaoru; Yakushi, Kyuya
2015-11-01
We have performed infrared spectroscopy in (TMTTF)2TaF6 (TMTTF: tetramethyltetrathiafulvalene) to investigate the relationship between the charge order (CO) state and the antiferromagnetic (AF) insulating ground state. A clear peak splitting corresponding to the charge disproportionation was observed below the CO transition temperature. We estimated the degree of charge disproportionation, Δρ = ρrich - ρpoor, as 0.28e from the peak splitting and found that the CO state coexists with the AF state and there is no charge redistribution below the AF transition.
Field-induced cluster spin glass and inverse symmetry breaking enhanced by frustration
NASA Astrophysics Data System (ADS)
Schmidt, M.; Zimmer, F. M.; Magalhaes, S. G.
2018-03-01
We consider a cluster disordered model to study the interplay between short- and long-range interactions in geometrically frustrated spin systems under an external magnetic field (h). In our approach, the intercluster long-range disorder (J) is analytically treated to get an effective cluster model that is computed exactly. The clusters follow a checkerboard lattice with first-neighbor (J1) and second-neighbor (J2) interactions. We find a reentrant transition from the cluster spin-glass (CSG) state to a paramagnetic (PM) phase as the temperature decreases for a certain range of h. This inverse symmetry breaking (ISB) appears as a consequence of both quenched disorder with frustration and h, that introduce a CSG state with higher entropy than the polarized PM phase. The competitive scenario introduced by antiferromagnetic (AF) short-range interactions increases the CSG state entropy, leading to continuous ISB transitions and enhancing the ISB regions, mainly in the geometrically frustrated case (J1 =J2). Remarkably, when strong AF intracluster couplings are present, field-induced CSG phases can be found. These CSG regions are strongly related to the magnetization plateaus observed in this cluster disordered system. In fact, it is found that each field-induced magnetization jump brings a CSG region. We notice that geometrical frustration, as well as cluster size, play an important role in the magnetization plateaus and, therefore, are also relevant in the field-induced glassy states. Our findings suggest that competing interactions support ISB and field-induced CSG phases in disordered cluster systems under an external magnetic field.
Long-term biatrial recordings in post-operative atrial fibrillation.
Masè, M; Graffigna, A; Sinelli, S; Pallaoro, G; Nollo, G; Ravelli, F
2010-01-01
Although atrial fibrillation (AF) is a common complication of cardiac surgery, its pathophysiology remains unclear. The study of post-operative AF demands for the recording of cardiac electrical activity in correspondence of AF onset and progression. Long-term recordings in post-surgery patients could provide this information, but, to date, have been limited to surface signals, which precludes a characterization of the arrhythmic triggers and substrate. In this study we demonstrate the feasibility of a continuous long-term recording of atrial electrical activities from the right and left atria in post-surgery patients. Local atrial epicardial electrograms are acquired by positioning temporary pacing wires in the right and left atria at the end of the intervention, while three day recordings are obtained by a digital holter recorder, adapted to epicardial signal features. The capability of the system to map local atrial activity and the possibility to obtain quantitative information on atrial rate and synchronization from the processed epicardial signals are proven in representative examples. The quantitative description of local atrial properties opens new perspective in the investigation of post-surgery AF.
Cost-effectiveness of dabigatran for stroke prophylaxis in atrial fibrillation.
Shah, Shimoli V; Gage, Brian F
2011-06-07
Recent studies have investigated alternatives to warfarin for stroke prophylaxis in patients with atrial fibrillation (AF), but whether these alternatives are cost-effective is unknown. On the basis of the results from Randomized Evaluation of Long Term Anticoagulation Therapy (RE-LY) and other trials, we developed a decision-analysis model to compare the cost and quality-adjusted survival of various antithrombotic therapies. We ran our Markov model in a hypothetical cohort of 70-year-old patients with AF using a cost-effectiveness threshold of $50 000/quality-adjusted life-year. We estimated the cost of dabigatran as US $9 a day. For a patient with an average risk of major hemorrhage (≈3%/y), the most cost-effective therapy depended on stroke risk. For patients with the lowest stroke rate (CHADS2 stroke score of 0), only aspirin was cost-effective. For patients with a moderate stroke rate (CHADS2 score of 1 or 2), warfarin was cost-effective unless the risk of hemorrhage was high or quality of international normalized ratio control was poor (time in the therapeutic range <57.1%). For patients with a high stroke risk (CHADS(2) stroke score ≥3), dabigatran 150 mg (twice daily) was cost-effective unless international normalized ratio control was excellent (time in the therapeutic range >72.6%). Neither dabigatran 110 mg nor dual therapy (aspirin and clopidogrel) was cost-effective. Dabigatran 150 mg (twice daily) was cost-effective in AF populations at high risk of hemorrhage or high risk of stroke unless international normalized ratio control with warfarin was excellent. Warfarin was cost-effective in moderate-risk AF populations unless international normalized ratio control was poor.
Hypertension and atrial fibrillation: epidemiology, pathophysiology and therapeutic implications.
Lau, Y-F; Yiu, K-H; Siu, C-W; Tse, H-F
2012-10-01
Hypertension is one of the most important risk factors associated with atrial fibrillation (AF) and increased the risk of cardiovascular events in patients with AF. However, the pathophysiological link between hypertension and AF is unclear. Nevertheless, this can be explained by the hemodynamic changes of the left atrium secondary to long standing hypertension, resulting in elevated left atrium pressure and subsequently left atrial enlargement. Moreover, the activation of renin-angiotensin-aldosterone system (RAAS) activation in patients with hypertension induces left atrial fibrosis and conduction block in the left atrium, resulting in the development of AF. Accordingly, recent studies have shown that effective blockage of RAAS by angiotensin converting enzyme inhibitors or angiotensin receptor antagonist may be effective in both primary and secondary prevention of AF in patients with hypertension, although with controversies. In addition, optimal antithrombotic therapy, blood pressure control as well as rate control for AF are key to the management of patients with AF.
Spitzer, Stefan Georg; Károlyi, László; Rämmler, Carola; Scharfe, Frank; Weinmann, Thomas; Zieschank, Mirko; Langbein, Anke
2017-01-01
A patient-tailored ablation approach focused on the elimination of both pulmonary vein triggers as well as substrate drivers may result in favorable outcomes in recurrent persistent AF patients. We evaluated the long-term outcomes of rotor ablation combined with conventional pulmonary vein isolation (PVI) in patients with recurrent nonparoxysmal AF. Fifty-eight consecutive patients underwent FIRM-guided rotor ablation followed by conventional PVI for the treatment of recurrent nonparoxysmal AF. A software algorithm was used to display rotational activity at rotor sites by creating propagation maps from unipolar electrograms recorded using a 64-electrode basket catheter. These rotor sites were targeted for ablation, followed by conventional PVI. All patients had nonparoxysmal AF (83% longstanding persistent) and a previously failed conventional ablation procedure. Stable rotors were identified in all patients (mean of 3.0 ± 1.6 per patient), with 55.2% having right atrial rotors and 96.6% left atrial rotors, respectively. Complications occurred in 5.2% of patients, none related to the FIRM procedure. The median follow-up was 12 months. At 6 and 12 months of follow-up, 73.2% and 76.9% of patients remained free from AF/AT, respectively. Excluding 2 patients who underwent a successful redo ablation procedure/electrical cardioversion, at 12 months of follow-up, 69.2% were free from any AF/AT and 73.1% were free from AF after a single FIRM-guided ablation procedure. A high degree of success was observed in this cohort of primarily longstanding persistent AF patients treated for recurrent AF with FIRM-guided rotor ablation. Prospective randomized controlled trials are needed. © 2016 Wiley Periodicals, Inc.
Rao, Hygriv B; Saksena, Sanjeev
2005-08-01
Hybrid therapy strategies have combined antiarrhythmic drugs (AAD) with pacemakers, atrio-ventricular defibrillators (AV ICD) or atrial ablation individually. The feasibility combining AAD with dual site RA pacing (DAP) in an AV ICD has not been examined. We used an AV ICD with a novel lead configuration permitting DAP, antitachycardia pacing (ATP) or atrial shocks (ADF) in patients (pts) with refractory persistent or permanent AF. Hybrid therapy included linear RA ablation and/or focal ablation. Continuous DAP and automatic ATP with patient or physician activated ADF. 24 pts, mean age 66 +/- 10 yrs, with cardiac disease (22 pts), underwent insertion of an AVICD with dual RA leads. 20 patients had concomitant ablative procedures (RA only = 19, RA + LA = 1) and all pts continued previously ineffective AAD. During a follow-up of 2-36 months (mean 17 +/- 8 mos), rhythm control was restored in all pts & maintained long-term in 19 (83%) pts. 8 pts used AF termination therapies successfully. Device datalogs showed no episodes of AF in 6 pts, asymptomatic brief arrhythmias in 4 pts, infrequent paroxysmal AF in 9 pts & persistent AF recurred in 5 pts. AV ICD detection algorithms reliably detected AF or AT in the DAP mode in all pts. Intermittent brief P wave double counting occurred during AT in selected pts. No pt received inappropriate ADF therapy. 1. DAP can be safely incorporated in an AVICD devices for use in an hybrid therapy strategy for AF pts. 2. These devices can be effective for both AF prevention & termination. 3. Long term rhythm control can be achieved and documented by device datalogs in persistent and permanent AF.
Presence and transcriptional activity of anaerobic fungi in agricultural biogas plants.
Dollhofer, Veronika; Callaghan, Tony M; Griffith, Gareth W; Lebuhn, Michael; Bauer, Johann
2017-07-01
Bioaugmentation with anaerobic fungi (AF) is promising for improved biogas generation from lignocelluloses-rich substrates. However, before implementing AF into biogas processes it is necessary to investigate their natural occurrence, community structure and transcriptional activity in agricultural biogas plants. Thus, AF were detected with three specific PCR based methods: (i) Copies of their 18S genes were found in 7 of 10 biogas plants. (ii) Transcripts of a GH5 endoglucanase gene were present at low level in two digesters, indicating transcriptional cellulolytic activity of AF. (iii) Phylogeny of the AF-community was inferred with the 28S gene. A new Piromyces species was isolated from a PCR-positive digester. Evidence for AF was only found in biogas plants operated with high proportions of animal feces. Thus, AF were most likely transferred into digesters with animal derived substrates. Additionally, high process temperatures in combination with long retention times seemed to impede AF survival and activity. Copyright © 2017 Elsevier Ltd. All rights reserved.
Catheter ablation in patients with persistent atrial fibrillation
Kirchhof, Paulus; Calkins, Hugh
2017-01-01
Catheter ablation is increasingly offered to patients who suffer from symptoms due to atrial fibrillation (AF), based on a growing body of evidence illustrating its efficacy compared with antiarrhythmic drug therapy. Approximately one-third of AF ablation procedures are currently performed in patients with persistent or long-standing persistent AF. Here, we review the available information to guide catheter ablation in these more chronic forms of AF. We identify the following principles: Our clinical ability to discriminate paroxysmal and persistent AF is limited. Pulmonary vein isolation is a reasonable and effective first approach for catheter ablation of persistent AF. Other ablation strategies are being developed and need to be properly evaluated in controlled, multicentre trials. Treatment of concomitant conditions promoting recurrent AF by life style interventions and medical therapy should be a routine adjunct to catheter ablation of persistent AF. Early rhythm control therapy has a biological rationale and trials evaluating its value are underway. There is a clear need to generate more evidence for the best approach to ablation of persistent AF beyond pulmonary vein isolation in the form of adequately powered controlled multi-centre trials. PMID:27389907
Genetic Risk Prediction of Atrial Fibrillation
Lubitz, Steven A.; Yin, Xiaoyan; Lin, Henry J.; Kolek, Matthew; Smith, J. Gustav; Trompet, Stella; Rienstra, Michiel; Rost, Natalia S.; Teixeira, Pedro L.; Almgren, Peter; Anderson, Christopher D.; Chen, Lin Y.; Engström, Gunnar; Ford, Ian; Furie, Karen L.; Guo, Xiuqing; Larson, Martin G.; Lunetta, Kathryn L.; Macfarlane, Peter W.; Psaty, Bruce M.; Soliman, Elsayed Z.; Sotoodehnia, Nona; Stott, David J.; Taylor, Kent D.; Weng, Lu-Chen; Yao, Jie; Geelhoed, Bastiaan; Verweij, Niek; Siland, Joylene E.; Kathiresan, Sekar; Roselli, Carolina; Roden, Dan; van der Harst, Pim; Darbar, Dawood; Jukema, J. Wouter; Melander, Olle; Rosand, Jonathan; Rotter, Jerome I.; Heckbert, Susan R.; Ellinor, Patrick T.; Alonso, Alvaro; Benjamin, Emelia J.
2017-01-01
Background Atrial fibrillation (AF) is common and has a substantial genetic basis. Identification of individuals at greatest AF risk could minimize the incidence of cardioembolic stroke. Methods To determine whether genetic data can stratify risk for development of AF, we examined associations between AF genetic risk scores and incident AF in five prospective studies comprising 18,919 individuals of European ancestry. We examined associations between AF genetic risk scores and ischemic stroke in a separate study of 509 ischemic stroke cases (202 cardioembolic [40%]) and 3,028 controls. Scores were based on 11 to 719 common variants (≥5%) associated with AF at P-values ranging from <1×10−3 to <1×10−8 in a prior independent genetic association study. Results Incident AF occurred in 1,032 (5.5%) individuals. AF genetic risk scores were associated with new-onset AF after adjusting for clinical risk factors. The pooled hazard ratio for incident AF for the highest versus lowest quartile of genetic risk scores ranged from 1.28 (719 variants; 95%CI, 1.13–1.46; P=1.5×10−4) to 1.67 (25 variants; 95%CI, 1.47–1.90; P=9.3×10−15). Discrimination of combined clinical and genetic risk scores varied across studies and scores (maximum C statistic, 0.629–0.811; maximum ΔC statistic from clinical score alone, 0.009–0.017). AF genetic risk was associated with stroke in age- and sex-adjusted models. For example, individuals in the highest quartile of a 127-variant score had a 2.49-fold increased odds of cardioembolic stroke, versus those in the lowest quartile (95%CI, 1.39–4.58; P=2.7×10−3). The effect persisted after excluding individuals (n=70) with known AF (odds ratio, 2.25; 95%CI, 1.20–4.40; P=0.01). Conclusions Comprehensive AF genetic risk scores were associated with incident AF beyond clinical AF risk factors, with magnitudes of risk comparable to other clinical risk factors, though offered small improvements in discrimination. AF genetic risk was also associated with cardioembolic stroke in age- and sex-adjusted analyses. Efforts to determine whether AF genetic risk may improve identification of subclinical AF or distinguish stroke mechanisms are warranted. PMID:27793994
Singh, Sheldon M; d'Avila, Andre; Kim, Young-Hoon; Aryana, Arash; Mangrum, J Michael; Michaud, Gregory F; Dukkipati, Srinivas R; Barrett, Conor D; Heist, E Kevin; Parides, Michael K; Thorpe, Kevin E; Reddy, Vivek Y
2017-10-01
Controversy on the optimal ablation strategy for persistent atrial fibrillation (AF) exists with limited work evaluating a strategy of pulmonary vein isolation (PVI) alone when AF terminates during PVI. Thirty-five patients had AF termination during PVI in the Modified Ablation Guided by Ibutilide Use in Chronic Atrial Fibrillation (MAGIC-AF; ClinicalTrials.gov number: NCT01014741) study. The objective of the current study is to report the 1-year outcome after PVI alone in this unique patient group. The 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs was reported for the 35 patients in the MAGIC-AF study with persistent AF termination during or upon completion of PVI. Freedom from recurrent atrial arrhythmia was achieved in 60% of patients where AF terminated during PVI. Cavotricuspid isthmus flutter was common when AF terminated to a macro re-entrant flutter during PVI, and responsible for 92% of all flutter circuits with AF termination. Persistent AF termination during PVI may identify a subgroup of patients who experience a similar long-term clinical outcome with PVI ablation alone when compared with other more extensive persistent AF ablation strategies. Pulmonary vein isolation alone may be an appropriate tactic in this subgroup of persistent AF patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Persistent atrial fibrillation vs paroxysmal atrial fibrillation: differences in management.
Margulescu, Andrei D; Mont, Lluis
2017-08-01
Atrial fibrillation (AF) is the most common human arrhythmia. AF is a progressive disease, initially being nonsustained and induced by trigger activity, and progressing towards persistent AF through alteration of the atrial myocardial substrate. Treatment of AF aims to decrease the risk of stroke and improve the quality of life, by preventing recurrences (rhythm control) or controlling the heart rate during AF (rate control). In the last 20 years, catheter-based and, less frequently, surgical and hybrid ablation techniques have proven more successful compared with drug therapy in achieving rhythm control in patients with AF. However, the efficiency of ablation techniques varies greatly, being highest in paroxysmal and lowest in long-term persistent AF. Areas covered: In this review, we discuss the fundamental differences between paroxysmal and persistent AF and the potential impact of those differences on patient management, emphasizing the available therapeutic strategies to achieve rhythm control. Expert commentary: Treatment to prevent AF recurrences is suboptimal, particularly in patients with persistent AF. Emerging technologies, such as documentation of atrial fibrosis using magnetic resonance imaging and documentation of electrical substrate using advanced electrocardiographic imaging techniques are likely to provide valuable insights about patient-specific tailoring of treatments.
Colquhoun, Heather L; Carroll, Kelly; Eva, Kevin W; Grimshaw, Jeremy M; Ivers, Noah; Michie, Susan; Sales, Anne; Brehaut, Jamie C
2017-09-29
Audit and feedback (A&F) is a common strategy for helping health providers to implement evidence into practice. Despite being extensively studied, health care A&F interventions remain variably effective, with overall effect sizes that have not improved since 2003. Contributing to this stagnation is the fact that most health care A&F interventions have largely been designed without being informed by theoretical understanding from the behavioral and social sciences. To determine if the trend can be improved, the objective of this study was to develop a list of testable, theory-informed hypotheses about how to design more effective A&F interventions. Using purposive sampling, semi-structured 60-90-min telephone interviews were conducted with experts in theories related to A&F from a range of fields (e.g., cognitive, health and organizational psychology, medical decision-making, economics). Guided by detailed descriptions of A&F interventions from the health care literature, interviewees described how they would approach the problem of designing improved A&F interventions. Specific, theory-informed hypotheses about the conditions for effective design and delivery of A&F interventions were elicited from the interviews. The resulting hypotheses were assigned by three coders working independently into themes, and categories of themes, in an iterative process. We conducted 28 interviews and identified 313 theory-informed hypotheses, which were placed into 30 themes. The 30 themes included hypotheses related to the following five categories: A&F recipient (seven themes), content of the A&F (ten themes), process of delivery of the A&F (six themes), behavior that was the focus of the A&F (three themes), and other (four themes). We have identified a set of testable, theory-informed hypotheses from a broad range of behavioral and social science that suggest conditions for more effective A&F interventions. This work demonstrates the breadth of perspectives about A&F from non-healthcare-specific disciplines in a way that yields testable hypotheses for healthcare A&F interventions. These results will serve as the foundation for further work seeking to set research priorities among the A&F research community.
Panikker, Sandeep; Jarman, Julian W E; Virmani, Renu; Kutys, Robert; Haldar, Shouvik; Lim, Eric; Butcher, Charles; Khan, Habib; Mantziari, Lilian; Nicol, Edward; Foran, John P; Markides, Vias; Wong, Tom
2016-07-01
Left atrial appendage (LAA) electric isolation is reported to improve persistent atrial fibrillation (AF) ablation outcomes. However, loss of LAA mechanical function may increase thromboembolic risk. Concomitant LAA electric isolation and occlusion as part of conventional AF ablation has never been tested in humans. We therefore evaluated the feasibility, safety, and efficacy of LAA electric isolation and occlusion in patients undergoing long-standing persistent AF ablation. Patients with long-standing persistent AF (age, 68±7 years; left atrium diameter, 46±3 mm; and AF duration, 25±15 months) underwent AF ablation, LAA electric isolation, and occlusion. Outcomes were compared with a balanced (1:2 ratio) control group who had AF ablation alone. Among 22 patients who underwent ablation, LAA electric isolation was possible in 20. Intraprocedural LAA reconnection occurred in 17 of 20 (85%) patients, predominantly at anterior and superior locations. All were reisolated. LAA occlusion was successful in all 20 patients. There were no major periprocedural complications. Imaging at 45 days and 9 months confirmed satisfactory device position and excluded pericardial effusion. One of twenty (5%) patients had a gap of ≥5 mm requiring anticoagulation. Nineteen of twenty (95%) patients stopped warfarin at 3 months. Without antiarrhythmic drugs, freedom from AF at 12 months after a single procedure was significantly higher in the study group (19/20, 95%) than in the control group (25/40, 63%), P=0.036. Freedom from atrial arrhythmias was demonstrated in 12 of 20 (60%) and 18 of 20 (90%) patients after 1 and ≤2 procedures (mean, 1.3), respectively. Persistent AF ablation, LAA electric isolation, and mechanical occlusion can be performed concomitantly. This technique may improve the success of persistent AF ablation while obviating the need for chronic anticoagulation. URL: https://clinicaltrials.gov. Unique identifier: NCT02028130. © 2016 American Heart Association, Inc.
Aflatoxins contamination of maize in Serbia: the impact of weather conditions in 2015.
Janić Hajnal, Elizabet; Kos, Jovana; Krulj, Jelena; Krstović, Saša; Jajić, Igor; Pezo, Lato; Šarić, Bojana; Nedeljković, Nataša
2017-11-01
In recent years climate changes recorded in temperate regions of Europe have led to aflatoxin (AF) contamination of maize. Thus, the aim of this study was to investigate the influence of weather conditions on levels of aflatoxin B 1 (AFB1), aflatoxin B 2 (AFB2), aflatoxin G 1 (AFG1) and aflatoxin G 2 (AFG2) in 180 maize samples collected from the main maize-growing regions (Western Bačka, North Banat, South Banat and Central Serbia) in Serbia after harvest in 2015. The concentrations of AFs were determined by a validated HPLC method with post-column derivatisation and fluorescence detection (HPLC-FLD). The presence of AFB1, AFB2, AFG1 and AFG2 was detected in 57.2%, 13.9%, 5.6% and 2.8% of maize samples in the concentration ranges of 1.3-88.8 µg kg - 1 , 0.60-2.8 µg kg - 1 , 1.8-28.5 µg kg - 1 and 2.1-7.5 µg kg - 1 respectively. The recorded smaller amount of precipitation and especially higher air temperatures during the summer of 2015 were favourable for AF production, which resulted in 32.2% and 21.1% of samples being unsuitable for human consumption, since AFB1 and the sum of AFs concentrations were above 5.0 and 10.0 µg kg - 1 respectively. Furthermore, the findings in this study indicate that the microclimate conditions in the investigated regions had a great influence on the contamination frequency of maize with AFs. The highest percentage of samples unsuitable for human consumption, considering both AFB1 and total AFs content were 72.5% and 51.5% respectively from Central Serbia, whilst the lowest percentages of 15.6% and 6.2% respectively were found in Western Bačka. These findings confirmed that maize should be continuously monitored in order to protect human and animal health from the harmful effects caused by AFs contamination.
Jolly, Jasleen K; Edwards, Thomas L; Moules, Jonathan; Groppe, Markus; Downes, Susan M; MacLaren, Robert E
2016-08-01
We set out to characterize the pattern of fundus autofluorescence (AF) loss in choroideremia (CHM) patients of varying ages and disease severity in order to determine the average rate of progression of this potential disease biomarker. Fifty consecutive CHM patients (100 eyes) attending outpatient clinics at Oxford Eye Hospital underwent analysis with the Heidelberg OCT Spectralis with autofluorescence capabilities. The area of residual AF was traced using Heidelberg Eye Explorer. Bland-Altman analysis was used to calculate the coefficient of repeatability (CR). The degree of AF loss was correlated to different ages and the pattern of residual AF constructed into color-coded maps in order to gain insight into the mechanism of disease progression. The CR for measurement of AF area is <1%, indicating that a small change is likely to be significant. Correlation of patient age and area of residual AF produced a clinically relevant index of expected anatomic disease. Progression is 7.7% of the residual area each year (95% confidence intervals 7.0%-8.2%) and follows a logarithmic pattern with age (r = 0.95, P < 0.001). From this we derived the mean half-life of AF as 9 years. Qualitatively, the pattern of remaining AF centered on a point temporal to the fovea. The area of residual AF in CHM can be measured reproducibly and shows a distinct pattern of loss. The measured residual area is inversely correlated to age. The ratio of the two variables may provide useful information regarding the rate of progression for any one individual at a given point in time.
NASA Astrophysics Data System (ADS)
Yüksel, Yusuf
2018-05-01
We propose an atomistic model and present Monte Carlo simulation results regarding the influence of FM/AF interface structure on the hysteresis mechanism and exchange bias behavior for a spin valve type FM/FM/AF magnetic junction. We simulate perfectly flat and roughened interface structures both with uncompensated interfacial AF moments. In order to simulate rough interface effect, we introduce the concept of random exchange anisotropy field induced at the interface, and acting on the interface AF spins. Our results yield that different types of the random field distributions of anisotropy field may lead to different behavior of exchange bias.
Lone atrial fibrillation: where are we now?
Potpara, Tatjana S; Lip, Gregory Y
2011-10-01
There is a growing pandemic of atrial fibrillation (AF), affecting nearly 2% of the general adult population. Atrial fibrillation is commonly associated with structural heart disease, and AF itself causes a sequence of complex processes of electrical, contractile, and structural remodeling of the atrial myocardium, which facilitate further AF progression. Nonetheless, AF may also affect individuals aged ≤ 65 years who have no evidence of associated cardiopulmonary or other disease, including hypertension; this is otherwise referred to as "lone" AF and is considered to have a generally favorable prognosis. The true prevalence of lone AF is unknown. Growing insights into the diversity of numerous mechanisms involved in the pathogenesis of AF, including acute atrial stretch, structural and electrophysiological alterations, systemic inflammation, oxidative stress, autonomic imbalance, genetic predisposition, and many others, and increasing recognition of novel risk factors for AF, including obesity, metabolic syndrome, subclinical atherosclerosis, sleep apnea, alcohol consumption, and endurance sports, suggest that apparently lone AF might not be so "lone" in many patients, which could have important prognostic and therapeutic implications. In this article, we summarize the current knowledge of epidemiology, etiopathogenesis, and pathophysiology of so-called lone AF and discuss the issues of long-term prognosis and management of patients who have an apparently lone AF.
Porous silicon photoluminescence biosensor for rapid and sensitive detection of toxins
NASA Astrophysics Data System (ADS)
Melnyk, Yulia; Pavlova, Karyna; Myndrul, Valerii; Viter, Roman; Smyntyna, Valentyn; Iatsunskyi, Igor
2017-08-01
A rapid and low cost photoluminescence (PL) immunosensor for the determination of low concentrations of Ochratoxin A(OTA) and Aflatoxine B1 (AfB1) has been developed. This biosensor was based on porous silicon (PSi) fabricated by metal-assisted chemical etching (MACE) and modified by antibodies against OTA/AfB1 (anti-OTA/anti-AfB1). Biofunctionalization method of the PSi surface by anti-OTA/ anti-AfB1 was developed. The changes of the PL intensity after interaction of the immobilized anti-OTA/anti-AfB1with OTA/AfB1 antigens were used as biosensor signal, allowing sensitive and selective detection of OTA/AfB1 antigens in BSA solution. The sensitivity of the reported optical biosensor towards OTA/AfB1 antigens is in the range from 10-3 to 102 ng/ml.
Chen, Lin Y; Chung, Mina K; Allen, Larry A; Ezekowitz, Michael; Furie, Karen L; McCabe, Pamela; Noseworthy, Peter A; Perez, Marco V; Turakhia, Mintu P
2018-05-15
Our understanding of the risk factors and complications of atrial fibrillation (AF) is based mostly on studies that have evaluated AF in a binary fashion (present or absent) and have not investigated AF burden. This scientific statement discusses the published literature and knowledge gaps related to methods of defining and measuring AF burden, the relationship of AF burden to cardiovascular and neurological outcomes, and the effect of lifestyle and risk factor modification on AF burden. Many studies examine outcomes by AF burden classified by AF type (paroxysmal versus nonparoxysmal); however, quantitatively, AF burden can be defined by longest duration, number of AF episodes during a monitoring period, and the proportion of time an individual is in AF during a monitoring period (expressed as a percentage). Current guidelines make identical recommendations for anticoagulation regardless of AF pattern or burden; however, a review of recent evidence suggests that higher AF burden is associated with higher risk of stroke. It is unclear whether the risk increases continuously or whether a threshold exists; if a threshold exists, it has not been defined. Higher burden of AF is also associated with higher prevalence and incidence of heart failure and higher risk of mortality, but not necessarily lower quality of life. A structured and comprehensive risk factor management program targeting risk factors, weight loss, and maintenance of a healthy weight appears to be effective in reducing AF burden. Despite this growing understanding of AF burden, research is needed into validation of definitions and measures of AF burden, determination of the threshold of AF burden that results in an increased risk of stroke that warrants anticoagulation, and discovery of the mechanisms underlying the weak temporal correlations of AF and stroke. Moreover, developments in monitoring technologies will likely change the landscape of long-term AF monitoring and could allow better definition of the significance of changes in AF burden over time. © 2018 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Fujiu, Manna; Plante, Alain; Ohno, Tsutomu; Solomon, Dawit; Lehmann, Johannes; Fraser, James; Leach, Melissa; Fairhead, James
2014-05-01
Anthropogenic Dark Earths are soils generated through long-term human inputs of organic and pyrogenic materials. These soils were originally discovered in the Amazon, and have since been found in Australia and in this case in Africa. African Dark Earths (AfDE) are black, highly fertile and carbon-rich soils that were formed from the original highly-weathered infertile yellowish to red Oxisols and Ultisols through an extant but hitherto overlooked climate-smart sustainable soil management system that has long been an important feature of the indigenous West African agricultural repertoire. Studies have demonstrated that ADE soils in general have significantly different organic matter properties compared to adjacent non-DE soils, largely attributable to the presence of high concentrations of ash-derived carbon. Quantification and characterization of bulk soil organic matter of several (n=11) AfDE and non-AfDE pairs of surface (0-15 cm) soils using thermal analysis techniques (TG-DSC-EGA) confirmed substantial differences in SOM composition and the presence of pyrogenic C. Such pyrogenic organic matter is generally considered recalcitrant or relatively stable, but the goal of the current study was to characterize the presumably labile, more rapidly cycling, pools of C in AfDEs through the characterization of hot water- and pyrophosphate-extractable fractions, referred to as HWEOC and PyroC respectively. Extracts were analyzed for carbon content, as well as composition using fluorescence (EEM/PARAFAC) and high resolution mass spectrometry (FTICR-MS). The amount of extractable C as a proportion of total soil C was relatively low: less than ~0.8% for HWEOC and 2.8% for PyroC. The proportion of HWEOC did not differ (P = 0.18, paired t-test) between the AfDE and the non-AfDE soils, while the proportions of PyroC were significantly larger (P = 0.001) in the AfDE soils compared to the non-AfDE soils. Preliminary analysis of the EEM/PARAFAC data suggests that AfDE samples had a greater fraction of their DOM that was more humic-like than the paired non-AfDE samples, though differences were small. Similarly, FTICR-MS analysis of hot water extracts suggests that differences among the three sites analyzed were larger than between the paired AfDE and non-AfDE extracts. Overall, in spite of substantial differences in the composition of bulk SOM, the extractable fractions appear to be relatively similar between the AfDE and non-AfDE soils.
Kasbaoui, Naïma; Cooper, Jonathan; Mills, Daniel S; Burman, Oliver
2016-01-01
Free-roaming cats are exposed to a variety of risks, including involvement in road traffic accidents. One way of mitigating these risks is to contain cats, for example using an electronic boundary fence system that delivers an electric 'correction' via a collar if a cat ignores a warning cue and attempts to cross the boundary. However, concerns have been expressed over the welfare impact of such systems. Our aim was to determine if long-term exposure to an electronic containment system was associated with reduced cat welfare. We compared 46 owned domestic cats: 23 cats that had been contained by an electronic containment system for more than 12 months (AF group); and 23 cats with no containment system that were able to roam more widely (C group). We assessed the cats' behavioural responses and welfare via four behavioural tests (unfamiliar person test; novel object test; sudden noise test; cognitive bias test) and an owner questionnaire. In the unfamiliar person test, C group lip-licked more than the AF group, whilst the AF group looked at, explored and interacted more with the unfamiliar person than C group. In the novel object test, the AF group looked at and explored the object more than C group. No significant differences were found between AF and C groups for the sudden noise or cognitive bias tests. Regarding the questionnaire, C group owners thought their cats showed more irritable behaviour and AF owners thought that their cats toileted inappropriately more often than C owners. Overall, AF cats were less neophobic than C cats and there was no evidence of significant differences between the populations in general affective state. These findings indicate that an electronic boundary fence with clear pre-warning cues does not impair the long term quality of life of cats.
Kasbaoui, Naïma; Cooper, Jonathan; Mills, Daniel S.; Burman, Oliver
2016-01-01
Free-roaming cats are exposed to a variety of risks, including involvement in road traffic accidents. One way of mitigating these risks is to contain cats, for example using an electronic boundary fence system that delivers an electric ‘correction’ via a collar if a cat ignores a warning cue and attempts to cross the boundary. However, concerns have been expressed over the welfare impact of such systems. Our aim was to determine if long-term exposure to an electronic containment system was associated with reduced cat welfare. We compared 46 owned domestic cats: 23 cats that had been contained by an electronic containment system for more than 12 months (AF group); and 23 cats with no containment system that were able to roam more widely (C group). We assessed the cats’ behavioural responses and welfare via four behavioural tests (unfamiliar person test; novel object test; sudden noise test; cognitive bias test) and an owner questionnaire. In the unfamiliar person test, C group lip-licked more than the AF group, whilst the AF group looked at, explored and interacted more with the unfamiliar person than C group. In the novel object test, the AF group looked at and explored the object more than C group. No significant differences were found between AF and C groups for the sudden noise or cognitive bias tests. Regarding the questionnaire, C group owners thought their cats showed more irritable behaviour and AF owners thought that their cats toileted inappropriately more often than C owners. Overall, AF cats were less neophobic than C cats and there was no evidence of significant differences between the populations in general affective state. These findings indicate that an electronic boundary fence with clear pre-warning cues does not impair the long term quality of life of cats. PMID:27602572
dos Santos, Simone Nascimento; Henz, Benhur Davi; Zanatta, André Rodrigues; Barreto, José Roberto; Loureiro, Kelly Bianca; Novakoski, Clarissa; dos Santos, Marcus Vinícius Nascimento; Giuseppin, Fabio F.; Oliveira, Edna Maria; Leite, Luiz Roberto
2014-01-01
Background Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. Objective To evaluate the impact of AF ablation on estimated LV filling pressure. Methods A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. Results One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m2 ± 10.6 mL/m2 to 22.6 mL/m2 ± 1.1 mL/m2, p < 0.001) compared to the non-successful group (37.7 mL/m2 ± 14.3 mL/m2 to 37.5 mL/m2 ± 14.5 mL/m2, p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001). Conclusion Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure. PMID:25590928
Lee, Seungyup; Sahadevan, Jayakumar; Khrestian, Celeen M; Cakulev, Ivan; Markowitz, Alan; Waldo, Albert L
2015-12-01
The mechanism(s) of persistent and long-standing persistent (LSP) atrial fibrillation (AF) is/are poorly understood. We performed high-density, simultaneous, biatrial, epicardial mapping of persistent and LSP AF in patients undergoing open heart surgery (1) to test the hypothesis that persistent and LSP AF are due to ≥ 1 drivers, either focal or reentrant, and (2) to characterize associated atrial activation. Twelve patients with persistent and LSP AF (1 month to 9 years duration) were studied at open heart surgery. During AF, electrograms were recorded from both atria simultaneously for 1 to 5 minutes from 510 to 512 epicardial electrodes with ECG lead II. Thirty-two consecutive seconds of activation sequence maps were produced per patient. During AF, multiple foci (QS unipolar atrial electrograms) of different cycle lengths (mean, 175 ± 18 ms) were present in both atria in 11 of 12 patients. Foci (2-4 per patient, duration 5-32 s) were either sustained or intermittent, were predominantly found in the lateral left atrial free wall, and likely acted as drivers. Random and nonrandom breakthrough activation sites (initial r or R in unipolar atrial electrograms) were also found. In 1 of 12 patients, only breakthrough sites were found. All wave fronts emanated from foci and breakthrough sites, and largely either collided or merged with each other at variable sites. Repetitive focal QS activation occasionally generated repetitive wannabe reentrant activation in 5 of 12 patients. No actual reentry was found. During persistent and LSP AF in 12 patients, wave fronts emanating from foci and breakthrough sites maintained AF. No reentry was demonstrated. © 2015 American Heart Association, Inc.
Kakegawa, Wataru; Tsuzuki, Keisuke; Yoshida, Yukari; Kameyama, Kimihiko; Ozawa, Seiji
2004-07-01
Hippocampal CA3 pyramidal neurons receive synaptic inputs from both mossy fibres (MFs) and associational fibres (AFs). Long-term potentiation (LTP) at these synapses differs in its induction sites and N-methyl-D-aspartate receptor (NMDAR) dependence. Most evidence favours the presynaptic and postsynaptic mechanisms for induction of MF LTP and AF LTP, respectively. This implies that molecular and functional properties differ between MF and AF synapses at both presynaptic and postsynaptic sites. In this study, we focused on the difference in the postsynaptic trafficking of alpha-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptors (AMPARs) between these synapses. To trace the subunit-specific trafficking of AMPARs at each synapse, GluR1 and GluR2 subunits were introduced into CA3 pyramidal neurons in hippocampal organotypic cultures using the Sindbis viral expression system. The electrophysiologically-tagged GluR2 AMPARs, produced by the viral-mediated transfer of the unedited form of GluR2 (GluR2Q), were inserted into both MF and AF postsynaptic sites in a neuronal activity-independent manner. Endogenous Ca(2+)-impermeable AMPARs at these synapses were replaced with exogenous Ca(2+)-permeable receptors, and Ca(2+) influx via the newly expressed postsynaptic AMPARs induced NMDAR-independent LTP at AF synapses. In contrast, no GluR1 AMPAR produced by the gene transfer was constitutively incorporated into AF postsynaptic sites, and only a small amount into MF postsynaptic sites. The synaptic trafficking of GluR1 AMPARs was triggered by the activity of Ca(2+)/calmodulin-dependent kinase II or high-frequency stimulation to induce LTP at AF synapses, but not at MF synapses. These results indicate that MF and AF postsynaptic sites possess distinct properties for AMPAR trafficking in CA3 pyramidal neurons.
Role of Rotors in the Ablative Therapy of Persistent Atrial Fibrillation
Schricker, Amir A; Zaman, Junaid; Narayan, Sanjiv M
2015-01-01
Atrial fibrillation (AF) ablation is increasingly used to maintain sinus rhythm yet its results are sub-optimal, especially in patients with persistent AF or prior unsuccessful procedures. Attempts at improvement have often targeted substrates that sustain AF after it is triggered, yet those mechanisms are debated. Many studies now challenge the concept that AF is driven by self-sustaining disordered wavelets, showing instead that localised drivers (rotors) may drive disorder via a process known as fibrillatory conduction. Novel mapping using wide-area recordings, physiological filtering and phase analysis demonstrates rotors in human AF. Contact mapping with focal impulse and rotor modulation (FIRM) shows that localised ablation at sources can improve procedural success in many populations on long-term follow up and some newer approaches to rotor mapping are qualitatively similar. This review critically evaluates the data on rotor mapping and ablation, which advances our conceptual understanding of AF and holds the promise of substantially improving ablative outcomes in patients with persistent AF. PMID:26835100
Health Literacy and Atrial Fibrillation: Relevance and Future Directions for Patient-centred Care.
Aronis, Konstantinos N; Edgar, Brittany; Lin, Wendy; Martins, Maria Auxiliadora Parreiras; Paasche-Orlow, Michael K; Magnani, Jared W
2017-01-01
Atrial fibrillation (AF) is a common cardiac arrhythmia with significant clinical outcomes, and is associated with high medical and social costs. AF is complicated for patients because of its specialised terminology, long-term adherence, symptom monitoring, referral to specialty care, array of potential interventions and potential for adversity. Health literacy is a frequently under-recognised, yet fundamental, component towards successful care in AF. Health literacy is defined as the capacity to obtain, process and understand health information, and has had markedly limited study in AF. However, health literacy could contribute to how patients interpret symptoms, navigate care, and participate in treatment evaluation and decision-making. This review aims to summarise the clinical importance and essential relevance of health literacy in AF. We focus here on central aspects of AF care that are most related to self-care, including understanding the symptoms of AF, shared decision-making, adherence and anticoagulation for stroke prevention. We discuss opportunities to enhance AF care based on findings from the literature on health literacy, and identify important gaps. Our overall objective is to articulate the importance and relevance of integrating health literacy in the care of individuals with AF.
Sasaki-Haraguchi, Noriko; Ikuyama, Takeshi; Yoshii, Shogo; Takeuchi-Andoh, Tomoko; Frendewey, David; Tani, Tokio
2015-01-01
Exons are ligated in an ordered manner without the skipping of exons in the constitutive splicing of pre-mRNAs with multiple introns. To identify factors ensuring ordered exon joining in constitutive pre-mRNA splicing, we previously screened for exon skipping mutants in Schizosaccharomyces pombe using a reporter plasmid, and characterized three exon skipping mutants named ods1 (ordered splicing 1), ods2, and ods3, the responsible genes of which encode Prp2/U2AF59, U2AF23, and SF1, respectively. They form an SF1-U2AF59-U2AF23 complex involved in recognition of the branch and 3′ splice sites in pre-mRNA. In the present study, we identified a fourth ods mutant, ods4, which was isolated in an exon-skipping screen. The ods4 + gene encodes Cwf16p, which interacts with the NineTeen Complex (NTC), a complex thought to be involved in the first catalytic step of the splicing reaction. We isolated two multi-copy suppressors for the ods4-1 mutation, Srp2p, an SR protein essential for pre-mRNA splicing, and Tif213p, a translation initiation factor, in S. pombe. The overexpression of Srp2p suppressed the exon-skipping phenotype of all ods mutants, whereas Tif213p suppressed only ods4-1, which has a mutation in the translational start codon of the cwf16 gene. We also showed that the decrease in the transcriptional elongation rate induced by drug treatment suppressed exon skipping in ods4-1. We propose that Cwf16p/NTC participates in the early recognition of the branch and 3′ splice sites and cooperates with the SF1-U2AF59-U2AF23 complex to maintain ordered exon joining. PMID:26302002
Current knowledge of the species complex Anastrepha fraterculus (Diptera, Tephritidae) in Brazil
Vaníčková, Lucie; Hernández-Ortiz, Vicente; Bravo, Iara Sordi Joachim; Dias, Vanessa; Roriz, Alzira Kelly Passos; Laumann, Raul Alberto; Mendonça, Adriana de Lima; Paranhos, Beatriz Aguiar Jordão; do Nascimento, Ruth Rufino
2015-01-01
Abstract The study of the species complex Anastrepha fraterculus (Af complex) in Brazil is especially important in a taxonomical, evolutionary and pest management context, because there are evidences that some of them may occur in sympatry. In this review, we analyzed the main results supporting evidences that three cryptic species occur in Brazil. The taxonomical and phylogenetic relationships based on eggshell morphology, adult morphometrics, as well as cytotaxonomy and genetic differentiations are discussed. We also review available information on sexual behavior including acoustic communication of males during courtship and sexual incompatibility; and chemical signals involved in the communication between sexes, with a special focus on sex pheromones. We examined the role of long- and short-range pheromones (male-produced volatiles and cuticular hydrocarbons, respectively), their implications in sexual isolation, and their possible use for chemotaxonomic differentiation of the putative species of the Af complex. PMID:26798261
Vicedomini, Gabriele; Pappone, Carlo
2014-01-01
There is evidence for a higher prevalence of atrial fibrillation (AF) in athletes engaged in long-term endurance sports training compared with the general population. Although atrial anatomic adaptations, alterations in autonomic nervous system, chronic systemic inflammation and fibrosis have been proposed as potential mechanisms, they remain speculative. Medical therapy with long-term antiarrhythmic agents or ‘pill in the pocket’ medications is hampered by limitations, such as sports eligibility and interference with exercise tolerance. AF ablation represents a valid therapeutic option with results similar to these achieved in other patients. Nevertheless, further clinical trials are needed to confirm whether endurance sport practice affects the maintenance of sinus rhythm following catheter ablation of AF. PMID:26835059
A First-Order Methodology for Calculating Probability of Mission Success
1979-01-31
Af(A)/2 + T- fA1 A2 1/8 R(T) (A) -T Af(A)4,(A) + T Af(A)[Af(A) + 4)(A)1$3 A 11/4. 61~ a 2 T R T 2f2 ()+T4f2 ()7A2 -4-A2]/ R 2 f(A) T 2(1 + T 2(3A 2/2...Library ATTN: W. Wright, Jr. ATTN: P. Haas Management Science Associates ATTN: K. Kaplan Rand Corp. ATTN: A. Laupa Martin Marietta Corp, ATTN: C. Mow ATTN
Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D
2000-02-29
To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length <300 ms). Intermittent sensing of far-field R waves during sinus tachycardia caused 27 inappropriate AT/AF detections; these detections lasted 2.6+/-2.0 minutes. AT/AF was detected continuously in 27 of 28 patients who had spontaneous episodes of AT/AF (96%). The device memory recorded 90 appropriate AT/AF episodes lasting >1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.
Khomaziuk, I M; Habulavichene, Zh M; Khomaziuk, V A
2011-01-01
Particularities and clinical importance of the structural and functional changes of myocardium were estimated in Chernobyl disaster clean-up workers with atrial fibrillation (AF). We examined 122 men with AF, which was associated with ischemic heart disease and arterial hypertension. Paroxysmal AF was diagnosed in 42 patients, 80 patients had permanent AE Control group comprised 80 men without AF. Echocardiography and Doppler studies were performed using ultrasound scanner Aloka SSD-630 (Japan). Significant structural and functional changes of the heart were revealed already in paroxysmal AF and became more pronounced in permanent AF. Increased left atrial size, its ratio to left ventricular end diastolic diameter, diastolic dysfunction were important echocardiographic predictors of AF. Heart walls thickening was accompanied by disorders of myocardial relaxation, increase in myocardial mass led to ischemia, and together they promoted overload, dysfunction of atrium and development of AF. Obligatory echocardiographic examination of the Chernobyl disaster clean-up workers with ischemic heart disease and arterial hypertension is necessary for predicting AF early, ordering adequate therapy in proper time and improving prognosis.
Zhou, Neng-Zhi; Liu, Ping; Su, Xiao-Chuan; Liao, Yan-Hua; Lei, Ning-Sheng; Liang, Yong-Hong; Zhou, Shao-Huan; Lin, Wen-Si; Chen, Jie; Feng, Yu-Qi; Tang, Yang
2017-06-01
Aflatoxins (AFs) are highly toxic, mutagenic, carcinogenic, and teratogenic secondary metabolites produced by the toxigenic fungi Aspergillus flavus and Aspergillus parasiticus. AFs tend to contaminate a wide range of foods which is a serious and recurring food safety problem worldwide. Currently, immunoaffinity chromatography (IAC) has become the most conventional sample clean-up method for determining AFs in foodstuffs. However, IAC method is limited in the large-scale food analysis because it requires the use of expensive disposable cartridges and the IA procedure is time-consuming. Herein, to achieve the cost-effective determination of AFs in edible oils, we developed a promising solid-phase extraction (SPE) method based on commercially available humic acid-bonded silica (HAS) sorbent, followed by high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) analysis. In HAS-SPE, AFs can be captured by the HAS sorbent with both hydrophobic and hydrophilic interactions, whereas the oil matrix was captured only with the hydrophobic interactions. The oil matrix can be sufficiently washed off with isopropanol, while the AFs were still retained on the SPE packing, thus achieving selective extraction of AFs and clean-up of oil matrices. Under the optimal conditions of HAS-SPE, satisfactory recoveries ranging from 82% to 106% for four AFs (B 1 , B 2 , G 1 , and G 2 ) were achieved in various oil matrices, containing blended oil, tea oil, rapeseed oil, peanut oil, sunflower seed oil, corn oil, blended olive oil, rice oil, soybean oil, and sesame oil. Only minor matrix effects ranging from 99% to 105% for four AFs were observed. Moreover, the LODs of AFs between 0.012 and 0.035 μg/kg completely meet the regulatory levels fixed by the EU, China or other countries. The methodology was further validated for assaying the naturally contaminated peanut oils, and consistent results between the HAS-SPE and the referenced IAC were obtained. In addition, HAS-SPE can directly treat diluted oil sample without liquid-liquid extraction and is automatable, thus making it simple and convenient for the large-scale determination of AFs in edible oils. Using this method, we successfully detected four AFs in the naturally contaminated peanut oils, which is, to the best of our knowledge, the first report about the determination of AFs in edible oils using HA-based SPE. Copyright © 2017 Elsevier B.V. All rights reserved.
Yun, Miaoying; Li, Shengxu; Sun, Dianjianyi; Ge, Shaoqing; Lai, Chin-Chih; Fernandez, Camilo; Chen, Wei; Srinivasan, Sathanur R; Berenson, Gerald S
2015-02-01
The study assessed the hypothesis that smoking strengthens the association of adult arterial stiffness with long-term cumulative burden of blood pressure (BP) from childhood to adulthood. Tobacco smoking and elevated BPs are important risk factors of vascular stiffness. However, the synergistic effect of these two risk factors is not well established, especially for the long-term burden of elevated BP since childhood. The study cohort consisted of 945 adults (661 whites and 284 blacks, aged 24-43 years) who have BP measured 4-15 times since childhood (aged 4-17 years) in Bogalusa, Louisiana. The adult arterial stiffness was measured as aorta-femoral pulse wave velocity (afPWV); the total area under the curve (AUC) and incremental AUC were used as a measure of long-term burden and trends of BP, respectively. Increased adult afPWV was significantly associated with higher adulthood (P < 0.001), total AUC (P < 0.001) and incremental AUC (P < 0.001) values of SBP and DBP, but not with childhood BP, after adjusting for age, race, sex, BMI and heart rate. Furthermore, smoking was a significant predictor of increased adult afPWV and BP levels. In the interaction analyses, the increasing trend of afPWV with increasing adult SBP (P = 0.009) and its incremental AUC (P = 0.007) were significantly greater among the current smokers than among the nonsmokers. DBP showed a similar pattern regarding the smoking-BP interaction on afPWV. These results, by showing the synergistic effect of tobacco smoking and long-term BP measures from childhood to adulthood on arterial stiffening process, underscore the importance of undertaking preventive strategies early in life and smoking behavior control.
Wiesel, Joseph; Salomone, Thomas J
2017-10-15
Early detection of asymptomatic atrial fibrillation (AF) provides an opportunity to treat patients to reduce their risk of stroke. Long-term residents of skilled nursing facilities frequently have multiple risk factors for strokes due to AF and may benefit from screening for AF. Patients in a skilled nursing facility 65 years and older, without a history of AF and without a pacemaker or defibrillator, were evaluated using a Microlife WatchBP Home A automatic blood pressure monitor that can detect AF when set to a triple reading mode. Those with readings positive for AF were evaluated with a standard 12-lead electrocardiogram (ECG) or a 30-second single-channel ECG to confirm the presence of AF. A total of 101 patients were screened with an average age of 78 years, and 48 (48%) were female. Nine automatic blood pressure monitor readings were positive for possible AF. Of those, 7 (6.9%, 95% confidence intervals 3.0% to 14.2%) had AF confirmed with ECG. Only 2 (2%, 95% confidence interval 0.3% to 7.7%) were false-positive readings. One-time screening for AF using an automatic blood pressure monitor in a skilled nursing facility resulted in a high number of patients with newly diagnosed AF. Copyright © 2017 Elsevier Inc. All rights reserved.
Goto, Koji; Nakai, Kentaro; Shizuta, Satoshi; Morimoto, Takeshi; Shiomi, Hiroki; Natsuaki, Masahiro; Yahata, Mitsuhiko; Ota, Chihiro; Ono, Koh; Makiyama, Takeru; Nakagawa, Yoshihisa; Furukawa, Yutaka; Kadota, Kazushige; Takatsu, Yoshiki; Tamura, Takashi; Takizawa, Akinori; Inada, Tsukasa; Doi, Osamu; Nohara, Ryuji; Matsuda, Mitsuo; Takeda, Teruki; Kato, Masayuki; Shirotani, Manabu; Eizawa, Hiroshi; Ishii, Katsuhisa; Lee, Jong-Dae; Takahashi, Masaaki; Horie, Minoru; Takahashi, Mamoru; Miki, Shinji; Aoyama, Takeshi; Suwa, Satoru; Hamasaki, Shuichi; Ogawa, Hisao; Mitsudo, Kazuaki; Nobuyoshi, Masakiyo; Kita, Toru; Kimura, Takeshi
2014-07-01
The prevalence, intensity, safety, and efficacy of oral anticoagulation (OAC) in addition to dual antiplatelet therapy (DAPT) in "real-world" patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI) have not yet been fully evaluated. In the Coronary REvascularization Demonstrating Outcome Study in Kyoto registry cohort-2, a total of 1,057 patients with AF (8.3%) were identified among 12,716 patients undergoing first PCI. Cumulative 5-year incidence of stroke was higher in patients with AF than in no-AF patients (12.8% vs 5.8%, p <0.0001). Although most patients with AF had CHADS2 score ≥2 (75.2%), only 506 patients (47.9%) received OAC with warfarin at hospital discharge. Cumulative 5-year incidence of stroke in the OAC group was not different from that in the no-OAC group (13.8% vs 11.8%, p = 0.49). Time in therapeutic range (TTR) was only 52.6% with an international normalized ratio of 1.6 to 2.6, and only 154 of 409 patients (37.7%) with international normalized ratio data had TTR ≥65%. Cumulative 5-year incidence of stroke in patients with TTR ≥65% was markedly lower than that in patients with TTR <65% (6.9% vs 15.1%, p = 0.01). In a 4-month landmark analysis in the OAC group, there was a trend for higher cumulative incidences of stroke and major bleeding in the on-DAPT (n = 286) than in the off-DAPT (n = 173) groups (15.1% vs 6.7%, p = 0.052 and 14.7% vs 8.7%, p = 0.10, respectively). In conclusion, OAC was underused and its intensity was mostly suboptimal in real-world patients with AF undergoing PCI, which lead to inadequate stroke prevention. Long-term DAPT in patients receiving OAC did not reduce stroke incidence. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Does Assessment for Learning Work to Promote Student Learning? The England Paradigm
ERIC Educational Resources Information Center
Vlachou, Maria A.
2015-01-01
Assessment for Learning (AfL) has influenced the assessment policy of many countries around the world because a range of research studies have shown the effectiveness of AfL on student learning. In the English context, although significant AfL developments have taken place in schools, its implementation seems not to have produced significant and…
Clinical predictors of risk for atrial fibrillation: implications for diagnosis and monitoring.
Brunner, Kyle J; Bunch, T Jared; Mullin, Christopher M; May, Heidi T; Bair, Tami L; Elliot, David W; Anderson, Jeffrey L; Mahapatra, Srijoy
2014-11-01
To create a risk score using clinical factors to determine whom to screen and monitor for atrial fibrillation (AF). The AF risk score was developed based on the summed odds ratios (ORs) for AF development of 7 accepted clinical risk factors. The AF risk score is intended to assess the risk of AF similar to how the CHA2DS2-VASc score assesses stroke risk. Seven validated risk factors for AF were used to develop the AF risk score: age, coronary artery disease, diabetes mellitus, sex, heart failure, hypertension, and valvular disease. The AF risk score was tested within a random population sample of the Intermountain Healthcare outpatient database. Outcomes were stratified by AF risk score for OR and Kaplan-Meier analysis. A total of 100,000 patient records with an index follow-up from January 1, 2002, through December 31, 2007, were selected and followed up for the development of AF through the time of this analysis, May 13, 2013, through September 6, 2013. Mean ± SD follow-up time was 3106±819 days. The ORs of subsequent AF diagnosis of patients with AF risk scores of 1, 2, 3, 4, and 5 or higher were 3.05, 12.9, 22.8, 34.0, and 48.0, respectively. The area under the curve statistic for the AF risk score was 0.812 (95% CI, 0.805-0.820). We developed a simple AF risk score made up of common clinical factors that may be useful to possibly select patients for long-term monitoring for AF detection. Copyright © 2014 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Vallejo, Mariana; Casas, Alejandro; Pérez-Negrón, Edgar; Moreno-Calles, Ana I; Hernández-Ordoñez, Omar; Tellez, Oswaldo; Dávila, Patricia
2015-02-19
Agroforestry systems (AFS) are valuable production systems that allow concealing benefits provision with conservation of biodiversity and ecosystem services. We analysed AFS of the zone of alluvial valleys of the Tehuacán-Cuicatlán Valley (TCV), Mexico, the most intensive agricultural systems within a region recognized for harbouring one of the most ancient agricultural experience of the New World. We hypothesized that the biodiversity conservation capacity of AFS would be directly related to traditional agricultural features and inversely related to management intensity. Agricultural practices, use frequency of machinery and chemical inputs, and proportion of forest and cultivated areas were described in 15 AFS plots in alluvial valleys of the Salado River in three villages of the region. With the information, we constructed a management intensity index and compared among plots and villages. We documented the reasons why people maintain wild plant species and traditional practices. Perennial plant species were sampled in vegetation of AFS (15 plots) and unmanaged forests (12 plots 500 m(2)) in order to compare richness, diversity and other ecological indicators in AFS and forest. In all studied sites, people combine traditional and intensive agricultural practices. Main agroforestry practices are ground terraces and borders surrounding AFS plots where people maintain vegetation. According to people, the reasons for maintaining shrubs and trees in AFS were in order of importance are: Beauty and shade provision (14% of people), fruit provision (7%), protection against strong wind, and favouring water and soil retention. We recorded 66 species of trees and shrubs in the AFS studied, 81% of them being native species that represent 38% of the perennial plant species recorded in forests sampled. Land tenure and institutions vary among sites but not influenced the actions for maintaining the vegetation cover in AFS. Plant diversity decreased with increasing agricultural intensity. Maintenance of vegetation cover did not confront markedly with the intensive agricultural practices. It is possible the expansion and enrichment of vegetation in terraces and borders of AFS. Information available on plant species and local techniques is potentially useful for a regional program of biodiversity conservation considering AFS as keystones.
García-Seara, Javier; Gude Sampedro, Francisco; Martínez Sande, Jose L; Fernández López, Xesus Alberte; Rodríguez Mañero, Moisés; González Melchor, Laila; Alvarez Alvarez, Belén; Iglesias Alvarez, Diego; González Juanatey, José Ramón
2016-09-01
We determined the effectiveness of the HATCH score in patients with typical atrial flutter (AFl) undergoing cavotricuspid isthmus (CTI) ablation to predict long-term atrial fibrillation (AF). We conducted an observational retrospective single-center cohort study including all patients admitted to our hospital for a CTI ablation between 1998 and 2010. The patients were divided into four categories: 1) new-onset AF (no prior AF and AF during follow-up (FU)); 2) old AF (prior AF and no AF during FU); 3) prior and post AF (AF prior and post CTI ablation); and 4) no AF. Four hundred and eight patients were included. In patients without prior AF, the hazard ratio (HR) for new-onset AF during FU was 0.98 (CI 95%: 0.65-1.50; p = 0.95) and 1.00 (CI 95%: 0.57-1.77; p = 0.98) for HATCH ≥ 2 and HATCH ≥ 3, respectively. In patients with prior AF, the HR for AF was 1.41 (CI 95%: 0.87-2.28; p = 0.17) and 1.79 (CI 95%: 0.96-3.35; p = 0.06), for HATCH ≥ 2 and HATCH ≥ 3, respectively. Left atrial enlargement was positively correlated with the occurrence of AF during FU, especially in the subgroup without prior AF, which had a HR of 2.44 (CI 95%: 1.35-4.40; p = 0.003), a HR of 2.88 (CI 95%: 1.36-6.10; p = 0.006) and a HR of 3.68 (CI 95%: 1.71-7.94; p = 0.001), for slight, moderate and severely dilated left atrial dimension, respectively, compared with a normal value. HATCH score did not predict AF in patients with typical AFl who underwent CTI ablation. Basal left atrium dimension could help predict new-onset AF.
Wang, Xule; Huang, Congxin; Zhao, Qingyan; Huang, He; Tang, Yanhong; Dai, Zixuan; Wang, Xiaozhan; Guo, Zongwen; Xiao, Jinping
2015-04-01
The aim of the present study was to explore the effect of renal sympathetic denervation (RSD) on the progression of paroxysmal atrial fibrillation (AF) in canines with long-term intermittent atrial pacing. Nineteen beagles were randomly divided into sham-operated group (six dogs), control group (six dogs), and RSD group (seven dogs). Sham-operated group were implanted with pacemakers without pacing; control group were implanted with pacemakers with long-term intermittent atrial pacing; and RSD group underwent catheter-based RSD bilaterally and were simultaneously implanted with pacemakers. Atrial pacing was maintained for 8 h a day and a total of 12 weeks in the control group and RSD group. Echocardiography showed that the left atrial structure and function were significantly improved in the RSD group compared with the control group (P < 0.05). Compared with the control group, the RSD group had fewer incidences of AF and a shorter duration of AF (P < 0.05) after long-term intermittent atrial pacing. In addition to increased atrial effective refractory period (AERP) and AF cycle length, AERP dispersion and P-wave duration and dispersion were significantly decreased in the RSD group compared with the control group (P < 0.05). Atrial morphological evaluation suggested that fibrosis and ultrastructural changes induced by long-term intermittent atrial pacing were markedly suppressed in the RSD dogs compared with controls (P < 0.05). Immunohistochemistry results showed that connexin 43 distribution in RSD mid-myocardial was significantly fewer heterogeneous than that in control mid-myocardial (P < 0.05). Renal denervation inhibits the progression of paroxysmal AF, which might be related to the suppression of atrial electrophysiology and structural heterogeneity. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Porter, Michael; Spear, William; Akar, Joseph G; Helms, Ray; Brysiewicz, Neil; Santucci, Peter; Wilber, David J
2008-06-01
Complex fractionated atrial electrograms (CFAE) may identify critical sites for perpetuation of atrial fibrillation (AF) and provide useful targets for ablation. Current assessment of CFAE is subjective; automated detection algorithms may improve reproducibility, but their utility in guiding ablation has not been tested. In 67 patients presenting for initial AF ablation (42 paroxysmal, 25 persistent), LA and CS mapping were performed during induced or spontaneous AF. CFAE were identified by an online automated computer algorithm and displayed on electroanatomical maps. A mean of 28 +/- 18 sites/patient were identified (20 +/- 13% of mapped sites), and were more frequent during persistent AF. CFAE occurred most commonly within the CS, on the atrial septum, and around the pulmonary veins. Ablation initially targeting CFAE terminated AF in 88% of paroxysmal AF, but only 20% of persistent AF (P < 0.001). Subsequently, additional ablation was performed in all patients (PV isolation for paroxysmal AF, PV isolation + mitral and roof lines for persistent AF). Minimum follow-up was 1 year. One-year freedom from recurrent atrial arrhythmias without antiarrhythmic drug therapy after a single procedure was 90% for paroxysmal AF, and 68% for persistent AF. Ablation guided by automated detection of CFAE proved feasible, and was associated with a high AF termination rate in paroxysmal, but not persistent AF. As an adjunct to conventional techniques, it was associated with excellent long-term single procedure outcomes in both groups. Criteria for identifying optimal CFAE sites for ablation, and selection of patients most likely to benefit, require additional study.
Giacomantonio, Nicholas B; Bredin, Shannon S D; Foulds, Heather J A; Warburton, Darren E R
2013-04-01
This systematic review sought to evaluate critically the health benefits of physical activity among persons with atrial fibrillation (AF). AF is increasing in Western society. While health benefits of physical activity are well established, benefits of physical activity among individuals with AF are not clearly identified. Literature was retrieved systematically through searching electronic databases (MEDLINE, EMBASE, Cochrane), cross-referencing, and drawing on the authors' knowledge. Identified original research articles evaluated health benefits of physical activity among persons with AF or effects of physical activity on AF incidence. From 1056 individual citations, 36 eligible articles were identified. Moderate-intensity physical activity was found to improve exercise capacity, quality of life, and the ability to carry out activities of daily living among persons with AF (n = 6). Increased incidence of AF was not associated with physical activity among the general population (n = 2), although long-term vigorous endurance exercise may be associated with increased incidence of AF (n = 7), and greater risks may be associated with high-intensity physical activity among those with AF (n = 2). Moderate-intensity physical activity among individuals with AF does not adversely alter training outcomes, functional capacity, morbidity, or mortality compared with those in sinus rhythm (n = 12). Physical activity may improve management and treatment of AF (n = 6) and, among at-risk populations, may reduce incidence of AF (n = 3). In conclusion, moderate-intensity physical activity should be encouraged among persons with or at risk of AF. Further research is needed. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Benefit of Anticoagulation Therapy in Hyperthyroidism-Related Atrial Fibrillation.
Chan, Pak-Hei; Hai, Jojo; Yeung, Chun-Yip; Lip, Gregory Y H; Lam, Karen Siu-Ling; Tse, Hung-Fat; Siu, Chung-Wah
2015-08-01
Existing data on the risk of ischemic stroke in hyperthyroidism-related atrial fibrillation (AF) and the impact of long-term anticoagulation in these patients, particularly those with self-limiting AF, remain inconclusive. Risk of stroke in hyperthyroidism-related AF is the same as nonhyperthyroid counterparts. This was a single-center observational study of 9727 Chinese patients with nonvalvular AF from July 1997 to December 2011. Patients with AF diagnosed concomitantly with hyperthyroidism were identified. Primary and secondary endpoints were defined as hospitalization with ischemic stroke and intracranial hemorrhage in the first 2 years. Patient characteristics, duration of AF, and choice of antithrombotic therapy were recorded. Self-limiting AF was defined as <7 days' duration. Out of 9727 patients, 642 (6.6%) had concomitant hyperthyroidism and AF at diagnosis. For stroke prevention, 136 and 243 patients (21.1% and 37.9%) were prescribed warfarin and aspirin, respectively, whereas the remaining patients (41.0%) received no therapy. Ischemic stroke occurred in 50 patients (7.8%), and no patient developed hemorrhagic stroke. Patients with CHA2 DS2 -VASc of 0 did not develop stroke. Warfarin effectively reduced the incidence of stroke compared with aspirin or no therapy in patients with CHA2 DS2 -VASc ≥1 and non-self-limiting AF, but not in those with self-limiting AF or CHA2 DS2 -VASc of 0. Presence of hyperthyroidism did not confer additional risk of ischemic stroke compared with nonhyperthyroid AF. Patients with hyperthyroidism-related AF are at high risk of stroke (3.9% per year). Warfarin confers stroke prevention in patients with CHA2 DS2 -VASc ≥1 and non-self-limiting AF. Overall stroke risk was lower in hyperthyroid non-self-limiting AF patients compared with nonhyperthyroid counterparts. © 2015 Wiley Periodicals, Inc.
Kochhäuser, Simon; Jiang, Chen-Yang; Betts, Timothy R; Chen, Jian; Deisenhofer, Isabel; Mantovan, Roberto; Macle, Laurent; Morillo, Carlos A; Haverkamp, Wilhelm; Weerasooriya, Rukshen; Albenque, Jean-Paul; Nardi, Stefano; Menardi, Endrj; Novak, Paul; Sanders, Prashanthan; Verma, Atul
2017-04-01
Controversy exists about the impact of acute atrial fibrillation (AF) termination and prolongation of atrial fibrillation cycle length (AFCL) during ablation on long-term procedural outcome. The purpose of this study was to analyze the influence of AF termination and AFCL prolongation on freedom from AF in patients from the STAR AF II (Substrate and Trigger Ablation for Reduction of Atrial Fibrillation Trial-Part II) trial. Acute changes in AFCL and AF termination were collected during the index procedure of the STAR AF II trial and compared to recurrence of AF at 18 months. Recurrence was assessed by ECG, Holter (3, 6, 9, 12, 18 months), and weekly transtelephonic ECG monitoring for 18 months. AF terminated in 8% of the pulmonary vein isolation (PVI) arm, 45% in the PVI+complex electrogram arm, and 22% of the PVI+linear ablation arm (P <.001), but freedom from AF did not differ among the 3 groups (P = .15). Freedom from AF was significantly higher in patients who presented to the laboratory in sinus rhythm (SR) compared to those without AF termination (63% vs 44%, P = .007). Patients with AF termination had an intermediate outcome (53%) that was not significantly different from those in SR (P = .84) or those who did not terminate (P = .08). AF termination was a univariable predictor of success (P = .007), but by multivariable analysis, presence of early SR was the strongest predictor of success (hazard ratio 0.67, P = .004). Prolongation of AFCL was not predictive of 18-month freedom from AF. Acute AF termination and prolongation in AFCL did not consistently predict 18-month freedom from AF. Presence of SR before or early during the ablation was the strongest predictor of better outcome. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
A-site Ordered Chromium Perovskites, ACu3Cr4O12 with A = Trivalent Ions
NASA Astrophysics Data System (ADS)
Sugiyama, Jun; Nozaki, Hiroshi; Umegaki, Izumi; Higemoto, Wataru; Isobe, Masahiko; Takagi, Hidenori; Sakurai, Hiroya; Ansaldo, Eduardo J.; Brewer, Jess H.; Sassa, Yasmine; Forslund, Ola Kenji; Månsson, Martin
The magnetic ground state of the A-site ordered chromium perovskites, ACu3Cr4O12 with A = Y, La, Eu, and Lu has been investigated with μ+SR using powder samples prepared by a high-pressure technique. Weak transverse field measurements revealed that the four compounds enter into a magnetic phase below 230-260 K. Moreover, the transition temperature (TN) was found to decrease with increasing the size of A3+ ions. Zero field measurements indicated the formation of static antiferromagnetic (AF) order in ACu3Cr4O12 below TN. Furthermore, since the internal magnetic field in the AF phase is independent of A, the role of 4f electrons on the AF state is very limited and/or eventually absence in ACu3Cr4O12.
Vasconcelos, Tiago S; Prado, Vitor H M; da Silva, Fernando R; Haddad, Célio F B
2014-01-01
Anurans are a highly diverse group in the Atlantic Forest hotspot (AF), yet distribution patterns and species richness gradients are not randomly distributed throughout the biome. Thus, we explore how anuran species are distributed in this complex and biodiverse hotspot, and hypothesize that this group can be distinguished by different cohesive regions. We used range maps of 497 species to obtain a presence/absence data grid, resolved to 50×50 km grain size, which was submitted to k-means clustering with v-fold cross-validation to determine the biogeographic regions. We also explored the extent to which current environmental variables, topography, and floristic structure of the AF are expected to identify the cluster patterns recognized by the k-means clustering. The biogeographic patterns found for amphibians are broadly congruent with ecoregions identified in the AF, but their edges, and sometimes the whole extent of some clusters, present much less resolved pattern compared to previous classification. We also identified that climate, topography, and vegetation structure of the AF explained a high percentage of variance of the cluster patterns identified, but the magnitude of the regression coefficients shifted regarding their importance in explaining the variance for each cluster. Specifically, we propose that the anuran fauna of the AF can be split into four biogeographic regions: a) less diverse and widely-ranged species that predominantly occur in the inland semideciduous forests; b) northern small-ranged species that presumably evolved within the Pleistocene forest refugia; c) highly diverse and small-ranged species from the southeastern Brazilian mountain chain and its adjacent semideciduous forest; and d) southern species from the Araucaria forest. Finally, the high congruence among the cluster patterns and previous eco-regions identified for the AF suggests that preserving the underlying habitat structure helps to preserve the historical and ecological signals that underlie the geographic distribution of AF anurans.
Steinberg, Benjamin A; Gao, Haiyan; Shrader, Peter; Pieper, Karen; Thomas, Laine; Camm, A John; Ezekowitz, Michael D; Fonarow, Gregg C; Gersh, Bernard J; Goldhaber, Samuel; Haas, Sylvia; Hacke, Werner; Kowey, Peter R; Ansell, Jack; Mahaffey, Kenneth W; Naccarelli, Gerald; Reiffel, James A; Turpie, Alexander; Verheugt, Freek; Piccini, Jonathan P; Kakkar, Ajay; Peterson, Eric D; Fox, Keith A A
2017-12-01
Atrial fibrillation (AF) is the most common cardiac arrhythmia in the world. We aimed to provide comprehensive data on international patterns of AF stroke prevention treatment. Demographics, comorbidities, and stroke risk of the patients in the GARFIELD-AF (n=51,270), ORBIT-AF I (n=10,132), and ORBIT-AF II (n=11,602) registries were compared (overall N=73,004 from 35 countries). Stroke prevention therapies were assessed among patients with new-onset AF (≤6 weeks). Patients from GARFIELD-AF were less likely to be white (63% vs 89% for ORBIT-AF I and 86% for ORBIT-AF II) or have coronary artery disease (19% vs 36% and 27%), but had similar stroke risk (85% CHA 2 DS 2 -VASc ≥2 vs 91% and 85%) and lower bleeding risk (11% with HAS-BLED ≥3 vs 24% and 15%). Oral anticoagulant use was 46% and 57% for patients with a CHA 2 DS 2 -VASc=0 and 69% and 87% for CHA 2 DS 2 -VASc ≥2 in GARFIELD-AF and ORBIT-AF II, respectively, but with substantial geographic heterogeneity in use of oral anticoagulant (range: 31%-93% [GARFIELD-AF] and 66%-100% [ORBIT-AF II]). Among patients with new-onset AF, non-vitamin K antagonist oral anticoagulant use increased over time to 43% in 2016 for GARFIELD-AF and 71% for ORBIT-AF II, whereas use of antiplatelet monotherapy decreased from 36% to 17% (GARFIELD-AF) and 18% to 8% (ORBIT-AF I and II). Among new-onset AF patients, non-vitamin K antagonist oral anticoagulant use has increased and antiplatelet monotherapy has decreased. However, anticoagulation is used frequently in low-risk patients and inconsistently in those at high risk of stroke. Significant geographic variability in anticoagulation persists and represents an opportunity for improvement. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Rush, Kathy L; Hatt, Linda; Shay, Matt; Gorman, Nicole; Laberge, Carol G; Reid, R Colin; Wilson, Ryan
2017-09-01
The purpose of this study was to explore the stressors and coping strategies of older adults with persistent atrial fibrillation (AF) before and after direct current cardioversion. The study used a qualitative descriptive design. Sixteen patients were recruited through an AF clinic to participate in individual interviews prior to the cardioversion and at 6 and 12 weeks post procedure. Pre-cardioversion, older adults experienced symptom and health care-related stressors superimposed on existing non-AF stressors. They used a range of emotion and problem-focused coping. Non-AF stressors increased post procedure at the same time that participants perceived less need for coping strategies with a return to regular rhythm. There was a shift from AF to non-AF related stressors following the cardioversion but a decrease in coping strategies. Older adults with AF should be encouraged to maintain use of coping strategies to manage ongoing stress and reduce the risk of AF recurrence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Meng; Yi, Ming; Tian, Wei
Here, the complex interdigitated phases have greatly frustrated attempts to document the basic features of the superconductivity in the alkali metal intercalated iron chalcogenides. Here, using elastic neutron scattering, energy-dispersive x-ray spectroscopy, and resistivity measurements, we elucidate the relations of these phases in Rb xFe ySe 2-zS z. We find (i) the iron content is crucial in stabilizing the stripe antiferromagnetic (AF) phase with rhombic iron vacancy order (y ≈ 1.5), the block AF phase with root 5 x root 5 iron vacancy order (y ≈ 1.6), and the iron vacancy-free phase (y ≈ 2); and (ii) the iron vacancy-freemore » superconducting phase (z = 0) evolves into an iron vacancy-free metallic phase with sulfur substitution (z > 1.5) due to the progressive decrease of the electronic correlation strength. Both the stripe AF phase and the block AF phase are Mott insulators. The iron-rich compounds (y > 1.6) undergo a first order transition from an iron vacancy disordered phase at high temperatures into the √5 x √5 iron vacancy ordered phase and the iron vacancy-free phase below T s. Our data demonstrate that there are miscibility gaps between these three phases. The existence of the miscibility gaps in the iron content is a key to understanding the relationship between these complicated phases.« less
NASA Astrophysics Data System (ADS)
Choi, Hyeok-Cheol; You, Chun-Yeol; Kim, Ki-Yeon; Lee, Jeong-Soo; Shim, Je-Ho; Kim, Dong-Hyun
2010-06-01
We have investigated the dependence of magnetic anisotropies of the exchange-biased NiFe/FeMn/CoFe trilayers on the antiferromagnetic (AF) layer thickness (tAF) by measuring in-plane angular-dependent ferromagnetic resonance fields. The resonance fields of NiFe and CoFe sublayers are shifted to lower and higher values compared to those of single unbiased ferromagnetic (F) layers, respectively, due to the interfacial exchange coupling when tAF≥2nm . In-plane angular dependence of resonance field reveals that uniaxial and unidirectional anisotropies coexist in the film plane, however, they are not collinear with each other. It is found that these peculiar noncollinear anisotropies significantly depend on tAF . The angle of misalignment displays a maximum around tAF=5nm and converges to zero when tAF is thicker than 10 nm. Contributions from thickness-dependent AF anisotropy and spin frustrations at both F/AF interfaces due to the structural imperfections should be accounted in order to understand the AF-layer thickness dependence of noncollinear magnetic anisotropies.
Fan, Q I; Hanin, I
1999-01-01
AF64A (ethylcholine mustard aziridinium ion) was stereotaxically administered bilaterally (1 nmol/side) into rat lateral cerebral ventricles. Choline acetyltransferase (ChAT) activity and ChAT mRNA levels were measured at predetermined time points in the septo-hippocampal pathway and striatum, both well identified as rich in cholinergic neurons. AF64A caused a rapid but transient increase in ChAT mRNA (167%, P < 0.05) and ChAT activity (164%, P < 0.01) in the septum. By day 7 post treatment, there was a significant decrease in ChAT mRNA (42.5% of control, P < 0.05) in the septum although the ChAT activity still stayed high. This decreased ChAT mRNA level in the septum lasted for at least four weeks, and was paralleled by a long-lasting decrease in ChAT activity in the hippocampus. In the striatum, on the other hand, there were no observed changes in either ChAT activity or ChAT mRNA. These data suggest that the long term effect of AF64A on the septo-hippocampal cholinergic pathway may, at least in part, be due to an action of AF64A on gene expression in the cholinergic neuron. The difference in the response to AF64A between the septo-hippocampal and striatal cholinergic systems might be due to their difference in neuron types.
NASA Technical Reports Server (NTRS)
Wieserman, William R.; Schwarze, Gene E.; Niedra, Janis M.
2005-01-01
Magnetic component designers are always looking for improved soft magnetic core materials to increase the efficiency, temperature rating and power density of transformers, motors, generators and alternators, and energy density of inductors. In this paper, we report on the experimental investigation of commercially available cobalt-based amorphous alloys which, in their processing, were subjected to two different types of magnetic field anneals: A longitudinal magnetic field anneal or a transverse magnetic field anneal. The longitudinal field annealed material investigated was Metglas 2714A. The electrical and magnetic characteristics of this material were investigated over the frequency range of 1 to 200 kHz and temperature range of 23 to 150 C for both sine and square wave voltage excitation. The specific core loss was lower for the square than the sine wave voltage excitation for the same maximum flux density, frequency and temperature. The transverse magnetic field annealed core materials include Metglas 2714AF and Vacuumschmelze 6025F. These two materials were experimentally characterized over the frequency range of 10 to 200 kHz for sine wave voltage excitation and 23 C only. A comparison of the 2174A to 2714AF found that 2714AF always had lower specific core loss than 2714A for any given magnetic flux density and frequency and the ratio of specific core loss of 2714A to 2714AF was dependent on both magnetic flux density and frequency. A comparison was also made of the 2714A, 2714AF, and 6025F materials to two different tape thicknesses of the polycrystalline Supermalloy material and the results show that 2714AF and 6025F have the lowest specific core loss at 100 kHz over the magnetic flux density range of 0.1 to 0.4 Tesla.
Fuenzalida, Carolina; Hernández, Gritzel; Ferro, Inés; Siches, Carme; Ambrós, Àngels; Coll-Vinent, Blanca
2017-11-01
Health education improves the prognosis of many diseases. A previous study in patients with atrial fibrillation (AF) showed that an educational intervention by nurses at discharge from the emergency room (ER) decreased AF-related complications at 3-month follow-up. Our objective was to determine whether this intervention had a long-term effect. A prospective study assessed the outcomes of an intervention carried out upon discharge from the ER. Patients with a diagnosis of AF were randomized into two groups: the intervention group and the control group. The intervention consisted of a basic explanation about the arrhythmia and its treatment, precautions and warning signs, a training to take their pulse, and an individualized informational leaflet. At one year of follow-up, the clinical records for all participants were reviewed. The primary variable was the combined endpoint of AF-related or treatment-related complications and death. The study included 240 patients (116 intervention and 124 control), mean age 76.1±10.9years. The primary variable was significantly lower in the intervention group (31.9% vs 48.4%; p=0.005). Education by ER nurses at patient discharge helped to decrease AF-related complications at one year of follow-up. Copyright © 2017. Published by Elsevier Ltd.
NASA Technical Reports Server (NTRS)
Kornilova, L. N.; Cowings, P.; Arlashchenko, N. I.; Korneev, D. Iu; Sagalovich, S. V.; Sarantseva, A. V.; Toscano, W.; Kozlovskaia, I. B.
2003-01-01
The ability of 4 cosmonauts to voluntarily control their physiological parameters during the standing test was evaluated following a series of the adaptive feedback (AF) training sessions. Vegetative status of the cosmonauts during voluntary "relaxation" and "straining" was different when compared with its indices determined before these sessions. In addition, there was a considerable individual variability in the intensity and direction of the AF effects, and the range of parameters responding to AF. It was GCR which was the easiest one for the AF control.
Zuo, Hui-juan; Su, Jiang-lian; Lin, Yun; Zeng, Zhe-chun; Wang, Jin-wen
2010-08-24
To analyze the long-term compliance of oral anticoagulant therapy and the demands of disease management in patient with atrial fibrillation (AF). Inpatients with AF taking warfarin were collected from Department of Internal Medicine from January 1 to December 31, 2008. Inpatients from departments of surgery, ophthalmology, otorhinolaryngology, dermatology and pediatrics and those on a previous warfarin therapy were excluded. The data of patient profiles, medical history and anticoagulant treatment were collected from electronic medical record. And the status of anticoagulant treatment one year later and demands of disease management were inquired by telephone. A total of 268 AF patients received a telephone survey. Among them, 145 patients (54.1%) continued taking warfarin. Gender, age, type of AF, duration of AF and history of ischemic stroke was not significantly associated with the compliance of anticoagulant treatment. The odds ratio was 1.74 (95%CI: 0.67-4.47), 0.87 (95%CI: 0.30-2.53), 1.59 (95%CI: 0.35-1.09), 1.09 (95%CI: 0.61-1.93) and 0.44 (95%CI: 0.12-1.60) respectively. Among patients on warfarin, INR was monitored monthly in 88 patients (60.7%) and 70 patients (48.3%) had an INR value of 2.0-3.0. Among 123 withdrawal patients, 88 patients (71.5%) terminated treatment within 6 month. The common reasons included patient ignorance about long-term anticoagulant treatment (35.0%) and switching to aspirin because of a poor effect (24.4%). About 80% of patients wished to obtain instructions about INR monitoring and adjustment of drug dosage. Among them, 196/268 patients (73.1%) wished for a regular follow-up. And 176/196 patients (89.8%) opted for a telephone follow-up and 150/176 patients (85.2%) wanted to receive monthly instructions. The compliance of anticoagulation treatment and the target-meeting proportion of INR value are relative low. And the common reasons of withdrawal are patient ignorance about long-term anticoagulant treatment and switching to aspirin because of a poor effect. Disease management will meet most of AF patients' demands.
Observation of antiferromagnetic correlations in the Fermi-Hubbard model
NASA Astrophysics Data System (ADS)
Hart, R. A.; Duarte, P. M.; Yang, T. L.; Liu, X.; Hulet, R. G.; Paiva, T. C. L.; Huse, D.; Scalettar, R. T.; Trivedi, N.
2014-05-01
The physics of high temperature superconductors is not well understood, although it is known that the undoped parent compounds of many of them are antiferromagnetic (AF) insulators. The Fermi-Hubbard model at half filling (one atom per lattice site) is known to exhibit a phase transition to an antiferromagnetic insulator at a low temperature. We realize the Fermi-Hubbard model by loading ultracold 6Li atoms into a three-dimensional red-detuned optical lattice. We have compensated the confining potential of the lattice with blue-detuned laser beams in order to evaporatively cool the atoms. We have cooled sufficiently to observe AF correlations using spin-sensitive Bragg scattering of near-resonant light. Comparison with Quantum Monte Carlo (QMC) calculations indicates that the temperature is between 2-3 TN, where short-range correlations begin to develop. Bragg scattering combined with QMC provides sensitive thermometry in a previously unexplored regime. Supported by NSF, ONR, DARPA, and the Welch Foundation.
Coherent states formulation of polymer field theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Man, Xingkun; Villet, Michael C.; Materials Research Laboratory, University of California, Santa Barbara, California 93106
2014-01-14
We introduce a stable and efficient complex Langevin (CL) scheme to enable the first direct numerical simulations of the coherent-states (CS) formulation of polymer field theory. In contrast with Edwards’ well-known auxiliary-field (AF) framework, the CS formulation does not contain an embedded nonlinear, non-local, implicit functional of the auxiliary fields, and the action of the field theory has a fully explicit, semi-local, and finite-order polynomial character. In the context of a polymer solution model, we demonstrate that the new CS-CL dynamical scheme for sampling fluctuations in the space of coherent states yields results in good agreement with now-standard AF-CL simulations.more » The formalism is potentially applicable to a broad range of polymer architectures and may facilitate systematic generation of trial actions for use in coarse-graining and numerical renormalization-group studies.« less
Test-retest reproducibility of accommodative facility measures in primary school children.
Adler, Paul; Scally, Andrew J; Barrett, Brendan T
2018-05-08
To determine the test-retest reproducibility of accommodative facility (AF) measures in an unselected sample of UK primary school children. Using ±2.00 DS flippers and a viewing distance of 40 cm, AF was measured in 136 children (range 4-12 years, average 8.1 ± 2.1) by five testers on three occasions (average interval between successive tests: eight days, range 1-21 days). On each occasion, AF was measured monocularly and binocularly, for two minutes. Full datasets were obtained in 111 children (81.6 per cent). Intra-individual variation in AF was large (standard deviation [SD] = 3.8 cycles per minute [cpm]) and there was variation due to the identity of the tester (SD = 1.6 cpm). On average, AF was greater: (i) in monocular compared to binocular testing (by 1.4 cpm, p < 0.001); (ii) in the second minute of testing compared to the first (by 1.3 cpm, p < 0.001); (iii) in older compared to younger children (for example, AF for 4/5-year-olds was 3.3 cpm lower than in children ≥ 10 years old, p = 0.009); and (iv) on subsequent testing occasions (for example, visit-2 AF was 2.0 cpm higher than visit-1 AF, p < 0.001). After the first minute of testing at visit-1, only 36.9 per cent of children exceeded published normative values for AF (≥ 11 cpm monocularly and ≥ 8 cpm binocularly), but this rose to 83.8 per cent after the third test. Using less stringent pass criteria (≥ 6 cpm monocularly and ≥ 3 cpm binocularly), the equivalent figures were 82.9 and 96.4 per cent, respectively. Reduced AF did not co-exist with abnormal near point of accommodation or reduced visual acuity. The results reveal considerable intra-individual variability in raw AF measures in children. When the results are considered as pass/fail, children who initially exhibit normal AF continued to do so on repeat testing. Conversely, the vast majority of children with initially reduced AF exhibit normal performance on repeat testing. Using established pass/fail criteria, the prevalence of persistently reduced AF in this sample is 3.6 per cent. © 2018 Optometry Australia.
Cheng, Wen-Han; Lo, Li-Wei; Lin, Yenn-Jiang; Chang, Shih-Lin; Hu, Yu-Feng; Hung, Yuan; Chung, Fa-Po; Chang, Ting-Yung; Huang, Ting-Chung; Yamada, Shinya; Salim, Simon; Te, Abigail Louise D; Liao, Jo-Nan; Tuan, Ta-Chuan; Chao, Tze-Fan; Tsai, Tseng-Ying; Liu, Shin-Huei; Chen, Shih-Ann
2018-02-09
Cigarette smoking contributes to the development of atrial fibrosis via nicotine. The impact of smoking on ablation results in persistent atrial fibrillation (AF) is unknown. We aimed to investigate the triggers and long-term outcome between smokers and nonsmokers in the patients with persistent AF after catheter ablation. This study included 201 (177 males, 53 ± 10 years old) patients who received index catheter ablation, including pulmonary vein isolation (PVI) and complex fractionated atrial electrograms (CFAEs) ablation for persistent AF, retrospectively. Electrophysiological characteristics at the index procedure and long-term outcome were investigated to determine the differences between smokers and nonsmokers. Baseline characteristics were similar between two groups. Pulmonary vein (PV) triggers were found in all patients in the two groups. There was a higher incidence of nonpulmonary vein (NPV) triggers in smokers than in nonsmokers (61% vs. 31%, P < 0.05). There were no differences of the long-term ablation outcomes between smokers and nonsmokers in Kaplan-Meier analysis. Smokers with PV plus right atrial NPV (RA-NPV) triggers had a higher incidence of recurrence (log-rank P < 0.05) than those without RA-NPV triggers, but not in nonsmokers, after a mean follow-up of 31 ± 25 months. Smoking increases the incidence of NPV triggers in patients with persistent AF. Smokers who have RA-NPV triggers during index procedure do have a worse outcome after catheter ablation, indicating the harmful effects of nicotine to right atrium. © 2018 Wiley Periodicals, Inc.
Miura, Shiro; Arita, Takeshi; Domei, Takenori; Yamaji, Kyohei; Soga, Yoshimitsu; Hyodo, Makoto; Shirai, Shinichi; Ando, Kenji
2018-01-01
Optimal time to perform percutaneous mitral valvuloplasty (PMV) for patients with significant mitral stenosis (MS) and atrial fibrillation (AF) remains controversial. We sought to identify prognostic factors and evaluate long-term clinical outcomes after PMV of 77 consecutive patients with MS with a mitral valve area (MVA) <1.5 cm 2 . According to baseline heart rhythm, these patients were divided into sinus rhythm (SR; n = 24) and AF (n = 53) groups. The study endpoint was defined as a composite of all-cause mortality, admission for heart failure, mitral valve surgery, repeated PMV, and major cerebral vascular accident during follow-up. After successful PMV, there was no significant difference between the two groups in post-MVA and post-mitral mean pressure gradient. However, the New York Heart Association Functional Classification post-procedure was worse in the AF group (p < 0.01). In the AF group, event-free survival during follow-up was significantly lower compared with that of the SR group (p = 0.016). Independent predictors of clinical events were AF [hazard ratio (HR), 2.73; 95 % confidence interval (CI), 1.04-9.36; p = 0.03] and pulmonary artery systolic pressure (HR 2.57; 95 % CI 1.18-5.47; p = 0.017). Patients with AF at baseline were significantly associated with worse symptoms and higher event rates after successful PMV compared with those with SR. The clinical benefit of PMV may be considered for patients with MVA <1.5 cm 2 before the onset of AF.
Li, Zhan; Wang, Ximin; Wang, Weizong; Du, Juanjuan; Wei, Jinqiu; Zhang, Yong; Wang, Jiangrong; Hou, Yinglong
2017-07-01
Electrical remodeling has been reported to play a major role in the initiation and maintenance of atrial fibrillation (AF). Long non-coding RNAs (lncRNAs) have been increasingly recognized as contributors to the pathology of heart diseases. However, the roles and mechanisms of lncRNAs in electrical remodeling during AF remain unknown. In this study, the lncRNA expression profiles of right atria were investigated in AF and non-AF rabbit models by using RNA sequencing technique and validated using quantitative real-time polymerase chain reaction (qRT-PCR). A total of 99,843 putative new lncRNAs were identified, in which 1220 differentially expressed transcripts exhibited >2-fold change. Bioinformatics analysis was conducted to predict the functions and interactions of the aberrantly expressed genes. On the basis of a series of filtering pipelines, one lncRNA, TCONS_00075467, was selected to explore its effects and mechanisms on electrical remodeling. The atrial effective refractory period was shortened in vivo and the L-type calcium current and action potential duration were decreased in vitro by silencing of TCONS_00075467 with lentiviruses. Besides, the expression of miRNA-328 was negatively correlated with TCONS_00075467. We further demonstrated that TCONS_00075467 could sponge miRNA-328 in vitro and in vivo to regulate the downstream protein coding gene CACNA1C. In addition, miRNA-328 could partly reverse the effects of TCONS_00075467 on electrical remodeling. In summary, dysregulated lncRNAs may play important roles in modulating electrical remodeling during AF. Our study may facilitate the mechanism studies of lncRNAs in AF pathogenesis and provide potential therapeutic targets for AF. Copyright © 2017 Elsevier Ltd. All rights reserved.
Tan, Benny Kwong Huat; Tan, Chee Hong; Pushparaj, Peter Natesan
2005-04-29
The present study was designed to investigate the hypoglycemic and hypolipidemic activities of the semi-purified fractions of an ethanolic leaf extract of Averrhoa bilimbi (ABe) in high fat diet (HFD)-streptozotocin (STZ)-induced diabetic rats. Male Sprague-Dawley rats aged 10 weeks (200-250 g) were fed with a high fat diet obtained from Glen Forrest stock feeders (Western Australia) for 2 weeks prior to intraperitoneal injection with streptozotocin (STZ, 50 mg/kg). The leaves of A.bilimbi were exhaustively extracted with 80% ethanol, concentrated at 40 degrees C using a rotavapor and partitioned successively with butanol, ethylacetate and hexane to get aqueous (AF), butanol (BuF), ethylacetate (EF), and hexane fractions (HF). The fractions were freeze-dried to obtain powders of each. To investigate the effect of long term administration of the hypoglycemic fractions, diabetic animals were treated with vehicle (distilled water), AF (125 mg/kg), or BuF (125 mg/kg), twice a day for 14 days. The long term administration of AF and BuF at a dose of 125 mg/kg significantly (P < 0.05) lowered blood glucose and triglyceride concentrations when compared to the vehicle. The hepatic glycogen content was significantly higher (P < 0.05) in AF-treated rats when compared to diabetic control, however no change was found in the BuF-treated rats. Moreover, AF as well as BuF did not cause any significant change in the total cholesterol and HDL-cholesterol. There was also no difference in liver thiobarbituric acid reactive substances (TBARS) and cytochrome P450 values between AF, BuF and vehicle-treated control rats. In conclusion, the results indicate that AF is more potent than BuF in the amelioration of hyperglycemia and hyperlipidemia in HFD fed-STZ diabetic rats. Hence, AF is a potential source for the isolation of active principle(s) for oral anti-diabetic therapy.
NASA Technical Reports Server (NTRS)
Thomas, Anna E.; Shouse, Dale T.; Neuroth, Craig; Lynch, Amy; Frayne, Charles W.; Stutrud, Jeffrey S.; Corporan, Edwin; Hankins, Terry; Saxena, Nikita T.; Hendricks, Robert C.
2012-01-01
In order to realize alternative fueling for military and commercial use, the industry has set forth guidelines that must be met by each fuel. These aviation fueling requirements are outlined in MIL-DTL-83133F(2008) or ASTM D 7566-Annex standards and are classified as drop-in fuel replacements. This paper provides combustor performance data for synthetic-paraffinic-kerosene- (SPK-) type (Fisher-Tropsch (FT)) fuel and blends with JP-8+100, relative to JP-8+100 as baseline fueling. Data were taken at various nominal inlet conditions: 75 psia (0.52 MPa) at 500 aF (533 K), 125 psia (0.86 MPa) at 625 aF (603 K), 175 psia (1.21 MPa) at 725 aF (658 K), and 225 psia (1.55 MPa) at 790 aF (694 K). Combustor performance analysis assessments were made for the change in flame temperatures, combustor efficiency, wall temperatures, and exhaust plane temperatures at 3%, 4%, and 5% combustor pressure drop (% P) for fuel:air ratios (F/A) ranging from 0.010 to 0.025. Significant general trends show lower liner temperatures and higher flame and combustor outlet temperatures with increases in FT fueling relative to JP-8+100 fueling. The latter affects both turbine efficiency and blade/vane life. In general, 100% SPK-FT fuel and blends with JP-8+100 produce less particulates and less smoke and have lower thermal impact on combustor hardware.
NASA Astrophysics Data System (ADS)
Tam, David W.; Song, Yu; Man, Haoran; Cheung, Sky C.; Yin, Zhiping; Lu, Xingye; Wang, Weiyi; Frandsen, Benjamin A.; Liu, Lian; Gong, Zizhou; Ito, Takashi U.; Cai, Yipeng; Wilson, Murray N.; Guo, Shengli; Koshiishi, Keisuke; Tian, Wei; Hitti, Bassam; Ivanov, Alexandre; Zhao, Yang; Lynn, Jeffrey W.; Luke, Graeme M.; Berlijn, Tom; Maier, Thomas A.; Uemura, Yasutomo J.; Dai, Pengcheng
2017-02-01
We use neutron diffraction and muon spin relaxation to study the effect of in-plane uniaxial pressure on the antiferromagnetic (AF) orthorhombic phase in BaFe2As2 and its Co- and Ni-substituted members near optimal superconductivity. In the low-temperature AF ordered state, uniaxial pressure necessary to detwin the orthorhombic crystals also increases the magnetic ordered moment, reaching an 11% increase under 40 MPa for BaFe1.9Co0.1As2 , and a 15% increase for BaFe1.915Ni0.085As2 . We also observe an increase of the AF ordering temperature (TN) of about 0.25 K/MPa in all compounds, consistent with density functional theory calculations that reveal better Fermi surface nesting for itinerant electrons under uniaxial pressure. The doping dependence of the magnetic ordered moment is captured by combining dynamical mean field theory with density functional theory, suggesting that the pressure-induced moment increase near optimal superconductivity is closely related to quantum fluctuations and the nearby electronic nematic phase.
NASA Astrophysics Data System (ADS)
Gamadia, Mark Noel
In order to gain valuable market share in the growing consumer digital still camera and camera phone market, camera manufacturers have to continually add and improve existing features to their latest product offerings. Auto-focus (AF) is one such feature, whose aim is to enable consumers to quickly take sharply focused pictures with little or no manual intervention in adjusting the camera's focus lens. While AF has been a standard feature in digital still and cell-phone cameras, consumers often complain about their cameras' slow AF performance, which may lead to missed photographic opportunities, rendering valuable moments and events with undesired out-of-focus pictures. This dissertation addresses this critical issue to advance the state-of-the-art in the digital band-pass filter, passive AF method. This method is widely used to realize AF in the camera industry, where a focus actuator is adjusted via a search algorithm to locate the in-focus position by maximizing a sharpness measure extracted from a particular frequency band of the incoming image of the scene. There are no known systematic methods for automatically deriving the parameters such as the digital pass-bands or the search step-size increments used in existing passive AF schemes. Conventional methods require time consuming experimentation and tuning in order to arrive at a set of parameters which balance AF performance in terms of speed and accuracy ultimately causing a delay in product time-to-market. This dissertation presents a new framework for determining an optimal set of passive AF parameters, named Filter- Switching AF, providing an automatic approach to achieve superior AF performance, both in good and low lighting conditions based on the following performance measures (metrics): speed (total number of iterations), accuracy (offset from truth), power consumption (total distance moved), and user experience (in-focus position overrun). Performance results using three different prototype cameras are presented to further illustrate the real-world AF performance gains achieved by the developed approach. The major contribution of this dissertation is that the developed auto focusing approach can be successfully used by camera manufacturers in the development of the AF feature in future generations of digital still cameras and camera phones.
Beinart, Roy; Heist, E Kevin; Newell, John B; Holmvang, Godtfred; Ruskin, Jeremy N; Mansour, Moussa
2011-01-01
Risk of Stroke/TIA in Patients With Atrial Fibrillation. Most strokes in patients with atrial fibrillation (AF) arise from thrombus formation in left atrial appendage (LAA). Our aim was to identify LAA features associated with a higher stroke risk in patients with AF using magnetic resonance imaging and angiography (MRI/MRA). The study included 144 patients with nonvalvular AF who were not receiving warfarin and who underwent MRI/MRA prior to catheter ablation for AF. LAA volume, LAA depth, short and long axes of LAA neck, and numbers of lobes were measured. Of the 144 patients, 18 had a prior stroke or transient ischemic attack (TIA) (13 and 5, respectively). Compared with patients who had no history of stroke/TIA, these patients were older, had higher prevalence of hypertension and hyperlipidemia and had higher LAA volume (22.9 ± 9.6 cm(3) vs. 14.5 ± 7.1 cm(3) , P < 0.001). Their LAA depth (3.76 ± 0.9 cm vs. 3.21 ± 0.8 cm, P = 0.006) and the long and short axes of the LAA neck (3.12 ± 0.7 cm vs. 2.08 ± 0.7 cm, P < 0.001; 2.06 ± 0.5 cm vs. 1.37 ± 0.4 cm, P < 0.001, respectively) were larger. Using stepwise logistic regression model, the only statistically significant multivariable predictors of events were age (OR = 1.21 per year, 95% CI 1.06-1.38, P = 0.004), aspirin use (OR = 0.039, 95% CI 0.005-0.28, P = 0.001), and LAA neck dimensions (short axis × long axis) (OR = 3.59 per cm(2) , 95% CI 1.93-6.69, P < 0.001). LAA dimensions predict strokes/TIAs in patients with AF. LAA assessment by MRI/MRA can potentially be used as an adjunctive tool for risk stratification for embolic events in AF patients. © 2010 Wiley Periodicals, Inc.
Refinement of detecting atrial fibrillation in stroke patients: results from the TRACK-AF Study.
Reinke, F; Bettin, M; Ross, L S; Kochhäuser, S; Kleffner, I; Ritter, M; Minnerup, J; Dechering, D; Eckardt, L; Dittrich, R
2018-04-01
Detection of occult atrial fibrillation (AF) is crucial for optimal secondary prevention in stroke patients. The AF detection rate was determined by implantable cardiac monitor (ICM) and compared to the prediction rate of the probability of incident AF by software based analysis of a continuously monitored electrocardiogram at follow-up (stroke risk analysis, SRA); an optimized AF detection algorithm is proposed by combining both tools. In a monocentric prospective study 105 out of 389 patients with cryptogenic stroke despite extensive diagnostic workup were investigated with two additional cardiac monitoring tools: (a) 20 months' monitoring by ICM and (b) SRA during hospitalization at the stroke unit. The detection rate of occult AF was 18% by ICM (n = 19) (range 6-575 days) and 62% (n = 65) had an increased risk for AF predicted by SRA. When comparing the predictive accuracy of SRA to ICM, the sensitivity was 95%, specificity 35%, positive predictive value 27% and negative predictive value 96%. In 18 patients with AF detected by ICM, SRA also showed a medium risk for AF. Only one patient with a very low risk predicted by SRA developed AF revealed by ICM after 417 days. A combination of SRA and ICM is a promising strategy to detect occult AF. SRA is reliable in predicting incident AF with a high negative predictive value. Thus, SRA may serve as a cost-effective pre-selection tool identifying patients at risk for AF who may benefit from further cardiac monitoring by ICM. © 2017 EAN.
Rare presentation of a testicular angiofibroma treated with testis sparing surgery.
Leone, Luca; Fulvi, Paola; Sbrollini, Giulia; Filosa, Alessandra; Caraceni, Enrico; Marronaro, Angelo; Galosi, Andrea B
2016-12-30
Testicular benign tumors are very rare (< 5%). Testicular Angiofibroma (AF) is one of those, however the gold standard of treatment and follow-up is still unclear. A 47 years-old man with only one functioning testis was referred to our clinic for a palpable right testicular mass and atrophic contralateral testis. Patient underwent testis-sparing surgery with inguinal approach and intraoperative frozen sections examination with diagnosis of AF. Final histology confirmed AF. Post-operative follow-up was uneventful. Clinical and ultrasonographic follow-up was negative after 8 months. We report a conservative surgery in a patient with AF of the solitary testis. AF is a benign para-testicular fibrous neoplasm that could be misinterpreted as malignant tumor and treated with orchiectomy. Testis-sparing surgery is recommended in this case with intraoperative pathological examination. The excision of the mass is enough but in front of a possible recurrence a long follow-up is advisable.
Excessive Exercise in Endurance Athletes: Is Atrial Fibrillation a Possible Consequence?
Goodman, Jack M; Banks, Laura; Connelly, Kim A; Yan, Andrew; Backx, Peter H; Dorian, Paul
2018-05-29
Moderate physical activity levels are associated with increased longevity and lower risk of atrial fibrillation (AF). However, the relative risk of lone AF is 3-5 fold higher in intensive endurance-trained athletes compared to healthy adults. There is growing concern that 'excessive' endurance exercise may promote cardiac remodeling leading to long-term adverse consequences. The pathogenesis of exercise-induced AF is thought to arise from an interplay of multiple acute and chronic factors, including atrial enlargement, pro-fibrotic tendency, high vagal tone, and genotypic profile, which collectively promote adverse atrial remodeling. Clinical management of athletes with AF, while challenging, can be achieved using various strategies that may allow continued, safe exercise. Based on the overall risk-benefit evidence, it is premature to suggest 'excessive' exercise is unsafe or should be curtailed. Evidence-based assessment and treatment guidelines are required to ensure optimal and safe exercise among the growing number of endurance athletes with AF.
Soliman, Elsayed Z; Prineas, Ronald J; Case, L Douglas; Zhang, Zhu-ming; Goff, David C
2009-04-01
The paradox of the reported low prevalence of atrial fibrillation (AF) in blacks compared with whites despite higher stroke rates in the former could be related to limitations in the current methods used to diagnose AF in population-based studies. Hence, this study aimed to use the ethnic distribution of ECG predictors of AF as measures of AF propensity in different ethnic groups. The distribution of baseline measures of P-wave terminal force, P-wave duration, P-wave area, and PR duration (referred to as AF predictors) were compared by ethnicity in 15 429 participants (27% black) from the Atherosclerosis Risk in Communities (ARIC) study by unpaired t test, chi(2), and logistic-regression analysis, as appropriate. Cox proportional-hazards analysis was used to separately examine the association of AF predictors with incident AF and ischemic stroke. Whereas AF was significantly less common in blacks compared with whites (0.24% vs 0.95%, P<0.0001), similar to what has been reported in previous studies, blacks had significantly higher and more abnormal values of AF predictors (P<0.0001 for all comparisons). Black ethnicity was significantly associated with abnormal AF predictors compared with whites; odds ratios for different AF predictors ranged from 2.1 to 3.1. AF predictors were significantly and independently associated with AF and ischemic stroke with no significant interaction between ethnicity and AF predictors, findings that further justify using AF predictors as an earlier indicator of future risk of AF and stroke. There is a disconnect between the ethnic distribution of AF predictors and the ethnic distribution of AF, probably because the former, unlike the latter, do not suffer from low sensitivity. These results raise the possibility that blacks might actually have a higher prevalence of AF that might have been missed by previous studies owing to limited methodology, a difference that could partially explain the greater stroke risk in blacks.
Surgical treatment of atrial fibrillation.
Pagé, Pierre; Skanes, Allan C
2005-09-01
Surgery aims to eliminate atrial fibrillation (AF) through direct modification of the arrhythmogenic substratum. The Maze procedure, developed two decades ago, has proven to be clearly effective in restoring sinus rhythm in AF patients with or without associated organic cardiac disorders. Indications for surgery may be tailored to the clinical situation involved. In patients with continuous AF associated with structural heart disease (eg, valvular, congenital or coronary artery disease), the performance of a concomitant AF ablation procedure proven to add minimal morbidity to the operation may be highly beneficial to patient outcome. It is likely, although not entirely proven, that the restoration and maintenance of sinus rhythm after mitral valve surgery promotes survival by preventing tachycardia-induced cardiomyopathy and stroke. Novel strategies for AF surgery involve the use of alternate energy sources to create the lines of block in the atria and the simplification of the lesion pattern compared with the earlier Cox-Maze procedure. Published clinical data support the contention that left atrial ablation techniques performed concomitantly with valvular and/or coronary artery bypass surgery are likely to result in a 70% to 90% cure rate of AF in patients with preoperatively documented AF. Despite the lack of evidence for long-term outcome benefit, intraoperative pulmonary vein ablation, feasible with minimal morbidity, clearly appears to be an improvement over simply ignoring AF in patients undergoing cardiac surgery. Left atrial appendectomy appears warranted in patients with chronic persistent AF.
Aflatoxins in composite spices collected from local markets of Karachi, Pakistan.
Asghar, Muhammad Asif; Zahir, Erum; Rantilal, Summan; Ahmed, Aftab; Iqbal, Javed
2016-06-01
This survey was carried out to evaluate the occurrence of total aflatoxins (AFs; B1+B2+G1+G2) in unpacked composite spices. A total of 75 samples of composite spices such as biryani, karhai, tikka, nihari and korma masalas were collected from local markets of Karachi, Pakistan, and analysed using HPLC technique. The results indicated that AFs were detected in 77% (n = 58) samples ranging from 0.68 to 25.74 µg kg(-1) with a mean of 4.63 ± 0.95 µg kg(-1). In 88% (n = 66) samples, AFs level was below the maximum limits (ML = 10 µg kg(-1)) as imposed by EU. Furthermore, 61% (n = 46) tested samples contained AFs level between 1 and 10 µg kg(-1), 9% (n = 7) exhibited AFs contamination ranged 10-20 µg kg(-1) and only 3% (n = 2) of the investigated samples contained AFs levels higher than the ML of 20 µg kg(-1) for total aflatoxins as set by the USA. It was concluded that there is need to establish a strict and continuous national monitoring plan to improve safety and quality of spices in Pakistan.
Xuan, Huanling; Dai, Xianzhu; Li, Jing; Zhang, Xiaohui; Yang, Caiyun; Luo, Feng
2017-04-01
Cyanobacterial harmful algal blooms (CyanoHABs) cause severe environmental problems, economic losses and threaten human health seriously. In the present study, a Bacillus sp. strain, designated as AF-1, with strong antagonistic activity against plant pathogenic fungus Fusarium graminearum was isolated from purple soil. Bacillus sp. AF-1 selectively killed Microcystis aeruginosa at low cell density (1.6×10 3 cfu/mL), and showed the strongest bactericidal activity against M. aeruginosa NIES-843 (A e =93%, t=6d). The algicidal substances originated from strain AF-1 were stable in the temperature range of 35-100°C, and pH range of 3-11. Cell-free filtrate of AF-1 culture caused excessive accumulation of intracellular reactive oxygen species (ROS), cell death and the efflux of intracellular components of M. aeruginosa NIES-843 cells. The expression of genes recA, psbA1, psbD1, rbcL and mcyB, involved in DNA repair, photosynthesis and microcystin synthesis of NIES 843, were significantly influenced by the cell-free filtrate of AF-1 culture. Bacillus sp. AF-1 has the potential to be developed as a bifunctional biocontrol agent to control CyanoHABs and F. graminearum caused plant disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Bansal, Nisha; Fan, Dongjie; Hsu, Chi-yuan; Ordonez, Juan D.; Marcus, Gregory M.; Go, Alan S.
2013-01-01
Background Atrial fibrillation (AF) frequently occurs in patients with chronic kidney disease (CKD). However, the long-term impact of development of AF on the risk of adverse renal outcomes in patients with CKD is unknown. In this study, we determined the association between incident AF and risk of end-stage renal disease (ESRD) among adults with CKD. Methods and Results We studied adults with CKD (defined as persistent glomerular filtration rate [eGFR] <60 ml/min/1.73 m2 by the CKD-EPI equation) enrolled in Kaiser Permanente Northern California who were identified between 2002–2010 and who did not have prior ESRD or previously documented AF. Incident AF was identified using primary hospital discharge diagnoses and/or two or more outpatient visits for AF. Incident ESRD was ascertained from a comprehensive health plan registry for dialysis and renal transplant. Among 206,229 adults with CKD, 16,463 developed incident AF. During a mean follow-up of 5.1± 2.5 years, there were 345 cases of ESRD that occurred after development of incident AF (74 per 1000 person-years) compared with 6505 cases of ESRD during periods without AF (64 per 1000 person-years, P<0.001). After adjustment for potential confounders, incident AF was associated with a 67% increase in rate of ESRD (hazard ratio 1.67, 95% confidence interval: 1.46–1.91). Conclusions Incident AF is independently associated with increased risk of developing ESRD in adults with CKD. Further study is needed to identify potentially modifiable pathways through which AF leads to a higher risk of progression to ESRD. PMID:23275377
The burden of proof: The current state of atrial fibrillation prevention and treatment trials
Zakeri, Rosita; Van Wagoner, David R.; Calkins, Hugh; Wong, Tom; Ross, Heather M.; Heist, E. Kevin; Meyer, Timothy E.; Kowey, Peter R.; Mentz, Robert J.; Cleland, John G.; Pitt, Bertram; Zannad, Faiez; Linde, Cecilia
2017-01-01
Atrial fibrillation (AF) is an age-related arrhythmia of enormous socioeconomic significance. In recent years, our understanding of the basic mechanisms that initiate and perpetuate AF has evolved rapidly, catheter ablation of AF has progressed from concept to reality, and recent studies suggest lifestyle modification may help prevent AF recurrence. Emerging developments in genetics, imaging, and informatics also present new opportunities for personalized care. However, considerable challenges remain. These include a paucity of studies examining AF prevention, modest efficacy of existing antiarrhythmic therapies, diverse ablation technologies and practice, and limited evidence to guide management of high-risk patients with multiple comorbidities. Studies examining the long-term effects of AF catheter ablation on morbidity and mortality outcomes are not yet completed. In many ways, further progress in the field is heavily contingent on the feasibility, capacity, and efficiency of clinical trials to incorporate the rapidly evolving knowledge base and to provide substantive evidence for novel AF therapeutic strategies. This review outlines the current state of AF prevention and treatment trials, including the foreseeable challenges, as discussed by a unique forum of clinical trialists, scientists, and regulatory representatives in a session endorsed by the Heart Rhythm Society at the 12th Global CardioVascular Clinical Trialists Forum in Washington, DC, December 3–5, 2015. PMID:28161513
2009-03-01
8217 Clear old problem data Do While Trim(Sheets("Campaign").Range("AF" & CStr (LOOP_COUNTER))) <> "" LOOP_COUNTER = LOOP_COUNTER + 1 Loop Do While...Trim(Sheets("Campaign").Range("A" & CStr (LOOP_COUNTER))) <> "" ’ Loop through all problem instances Sheets("Campaign").Range("R1:AF1").Rows...total number of locations M = Sheets("Campaign").Range("F" & CStr (LOOP_COUNTER)) ’ Record total number of sensor types N
Plasticity of white matter connectivity in phonetics experts.
Vandermosten, Maaike; Price, Cathy J; Golestani, Narly
2016-09-01
Phonetics experts are highly trained to analyze and transcribe speech, both with respect to faster changing, phonetic features, and to more slowly changing, prosodic features. Previously we reported that, compared to non-phoneticians, phoneticians had greater local brain volume in bilateral auditory cortices and the left pars opercularis of Broca's area, with training-related differences in the grey-matter volume of the left pars opercularis in the phoneticians group (Golestani et al. 2011). In the present study, we used diffusion MRI to examine white matter microstructure, indexed by fractional anisotropy, in (1) the long segment of arcuate fasciculus (AF_long), which is a well-known language tract that connects Broca's area, including left pars opercularis, to the temporal cortex, and in (2) the fibers arising from the auditory cortices. Most of these auditory fibers belong to three validated language tracts, namely to the AF_long, the posterior segment of the arcuate fasciculus and the middle longitudinal fasciculus. We found training-related differences in phoneticians in left AF_long, as well as group differences relative to non-experts in the auditory fibers (including the auditory fibers belonging to the left AF_long). Taken together, the results of both studies suggest that grey matter structural plasticity arising from phonetic transcription training in Broca's area is accompanied by changes to the white matter fibers connecting this very region to the temporal cortex. Our findings suggest expertise-related changes in white matter fibers connecting fronto-temporal functional hubs that are important for phonetic processing. Further studies can pursue this hypothesis by examining the dynamics of these expertise related grey and white matter changes as they arise during phonetic training.
[Characteristics and outcome of acute ischemic stroke patients with atrial fibrillation].
Li, Shenjun; Wang, Shucai; Gu, Mingming; Cao, Bingzhen
2015-11-17
To evaluate clinical characteristics and outcome of acute ischemic stroke patients with atrial fibrillation. Consecutive acute ischemic stroke patients who were hospitalized in the neurology department of General Hospital of Jinan Military Region were prospectively recruited from August 2010 to November 2013.The baseline datum including age, sex, National Institute of Health Stroke Scale (NIHSS), type of Oxfordshire Community Stroke Project (OCSP: total anterior circulation infarct, partial anterior circulation infarction, posterior circulation infarction and lacunar infarction), serum creatinine, serum albumin levels etc.were recorded.Atrial fibrillation (AF) was defined as a history of persistent atrial fibrillation or paroxysmal atrial fibrillation, supported by past electrocardiogram or diagnosed by the attending physicians based on physical examination, electrocardiogram and/or 24-hour electrocardiogram monitoring during hospitalization. Outcome was assessed by modified Rankin Scale (mRS) which was obtained 180 days after stroke by telephone interview (mRS ≤ 2 reflected good prognosis, and mRS>2 reflected unfavorable prognosis), and death defined as all-cause mortality. Multivariate regression model was used to analyze predictors of mortality and disability. Of the 965 patients included in this study, 113 (11.71%) had AF; valvular AF was observed in 11 patients (9.7%) among them.Only 4 patients with valvular AF and none of the patients with non-valvular AF took warfarin before the stroke event. 14.2% (16/113) acute ischemic stroke patients with AF took aspirin. Compared to patients without AF, patients with AF had a higher NIHSS score on admission (median 11 vs 5, P=0.000); were more often with diabetes (26.55% vs 9.74%, P=0.028), congestive heart failure (12.37% vs 11.03%, P=0.000), prior stroke (31.86% vs 21.83%, P=0.023), total anterior circulation infarct subtype (51.33% vs 19.37%, P=0.000); they were less often smokers (20.35% vs 37.32%, P=0.000), alcohol consumers (13.27% vs 27.58%, P=0.001), partial anterior circulation infarction subtype (24.78% vs 36.74%, P=0.012), lacunar infarct subtype (0 vs 17.61%, P=0.000); they had less often experienced myocardial infarction (11.50% vs 11.74%, P=0.041). AF was a significant independent prognostic factor for long-term poor outcomes (OR=2.227, 95%CI: 1.262-3.933, P=0.006). Oral anticoagulants are underused in AF patients.Brain infarction patients with AF is more severe than patients without AF; have higher frequency of total anterior circulation infarct subtype, prior stroke and lower frequency of lacunar infarct subtype. AF is a significant independent prognostic factor for long-term poor outcome in patients with acute brain infarction.
Gong, Ning; Liu, Yanping; Huang, Ruihua
2018-04-21
Carboxymethyl-chitosan (CMC)/bentonite composite was prepared by the method of membrane-forming, and characterized by Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD) techniques. The simultaneous adsorption of Cu 2+ and Acid fuchsin (AF) applying CMC/bentonite composite as an adsorbent in single or binary systems was investigated. The adsorption study was conducted systematically by varying the ratio of CMC to bentonite, adsorbent dosage, initial pH value, initial Cu 2+ (or AF) concentration, contact time and the interaction of two components in binary solutions. The results showed that the presence of Cu 2+ hindered the adsorption of AF, while the presence of AF almost had no influence on the adsorption of Cu 2+ in binary systems. The adsorption data of Cu 2+ and AF were both suitable for Langmuir isotherm model, and the maximum adsorption capacities of CMC/bentonite composite, according to the Langmuir isotherm model were 81.4 mg/g for Cu 2+ and 253.2 mg/g for AF at 298 K. The pseudo-second-order model could better describe the adsorption process of Cu 2+ and AF. Thermodynamic constant values illustrated that the adsorption of Cu 2+ was endothermic, while the adsorption process of AF was exothermic. Copyright © 2018. Published by Elsevier B.V.
Small ICBM Area Narrowing Report. Volume 1. Hard Mobile Launcher in Random Movement Basing Mode
1986-01-01
WHICH STATE INSTALLATION SERVICE ELIMINATED DE DOVER AIR FORCE BASE AF 4 DE REC AREA, FIRST ARMY ARMY 3 FL AVON PARK AIR FORCE RANGE AF 3 FL CAPE...PLANT NO. 47 AF 3 OH COLUMBUS DEF CONST SUPPLY CTR ARMY 4 OH COLUMBUS WEAPONS IND RES PLANT NAVY 3 OH EVANDALE PLANT NO. 36 AF 3 OH LIMA ARMY TANK...BLANK I I I I i I I I D-19 SENSITIVE FOR OFFICIAL USE ONLY 29I 331 J11 31 Alabam .._ _ . _ _ ............. _ . BAY MNETI ALLENTOW DE FUNII X0 LAN AT NO
Sterling, Mark; Huang, David T; Ghoraani, Behnaz
2015-01-01
We propose a new algorithm to predict the outcome of direct-current electric (DCE) cardioversion for atrial fibrillation (AF) patients. AF is the most common cardiac arrhythmia and DCE cardioversion is a noninvasive treatment to end AF and return the patient to sinus rhythm (SR). Unfortunately, there is a high risk of AF recurrence in persistent AF patients; hence clinically it is important to predict the DCE outcome in order to avoid the procedure's side effects. This study develops a feature extraction and classification framework to predict AF recurrence patients from the underlying structure of atrial activity (AA). A multiresolution signal decomposition technique, based on matching pursuit (MP), was used to project the AA over a dictionary of wavelets. Seven novel features were derived from the decompositions and were employed in a quadratic discrimination analysis classification to predict the success of post-DCE cardioversion in 40 patients with persistent AF. The proposed algorithm achieved 100% sensitivity and 95% specificity, indicating that the proposed computational approach captures detailed structural information about the underlying AA and could provide reliable information for effective management of AF.
Characterization of a novel antibacterial glycopeptide produced by Penicillium sp. M03.
Yang, W H; Zhang, W C; Lu, X M; Jiang, G S; Gao, P J
2009-04-01
To isolate a novel antibiotic termed AF from fermentation broth of Penicillium sp. M03 and to examine its antimicrobial activity, biological properties and structure characteristics. Sephadex LH-20 and HPLC were used to purify AF from fermentation broth of Penicillium sp. M03. The antimicrobial activity of AF was evaluated with the agar diffusion test. Amino acid and monosaccharide composition of AF was analysed by a HITACHI 835 detector and HPLC assay, respectively. Matrix-assisted laser desorption time of flight mass spectrometry, FT-IR and (1)H nuclear magnetic resonance spectra analyses were performed to examine the initial structure of AF. Eighty milligrams of AF was isolated as white powder from 1-l Penicillium sp. M03 fermentation broth. It consists of five amino acid and two monosaccharide residues and the molecular weight of it was 1017, and it was stable to beta-lactamase, heat, acid and alkali. AF showed inhibitory activity to a wide range of bacteria, particularly to multidrug-resistant Staphylococcus aureus. AF was a novel antibacterial glycopeptide with a broad inhibitory spectrum to pathogenic bacteria including multidrug-resistant agents. Furthermore, it is difficult to generate bacteria resistant to AF. Characterization of AF made it a potential antibiotic to fight against antibiotic-resistant bacterial pathogens.
Lim, Byounghyun; Hwang, Minki; Song, Jun-Seop; Ryu, Ah-Jin; Joung, Boyoung; Shim, Eun Bo; Ryu, Hyungon
2017-01-01
Background We previously reported that stable rotors are observed in in-silico human atrial fibrillation (AF) models, and are well represented by a dominant frequency (DF). In the current study, we hypothesized that the outcome of DF ablation is affected by conduction velocity (CV) conditions and examined this hypothesis using in-silico 3D-AF modeling. Methods We integrated 3D CT images of left atrium obtained from 10 patients with persistent AF (80% male, 61.8±13.5 years old) into in-silico AF model. We compared AF maintenance durations (max 300s), spatiotemporal stabilities of DF, phase singularity (PS) number, life-span of PS, and AF termination or defragmentation rates after virtual DF ablation with 5 different CV conditions (0.2, 0.3, 0.4, 0.5, and 0.6m/s). Results 1. AF maintenance duration (p<0.001), spatiotemporal mean variance of DF (p<0.001), and the number of PS (p = 0.023) showed CV dependent bimodal patterns (highest at CV0.4m/s and lowest at CV0.6m/s) consistently. 2. After 10% highest DF ablation, AF defragmentation rates were the lowest at CV0.4m/s (37.8%), but highest at CV0.5 and 0.6m/s (all 100%, p<0.001). 3. In the episodes with AF termination or defragmentation followed by 10% highest DF ablation, baseline AF maintenance duration was shorter (p<0.001), spatiotemporal mean variance of DF was lower (p = 0.014), and the number of PS was lower (p = 0.004) than those with failed AF defragmentation after DF ablation. Conclusion Virtual ablation of DF, which may indicate AF driver, was more likely to terminate or defragment AF with spatiotemporally stable DF, but not likely to do so in long-lasting and sustained AF conditions, depending on CV. PMID:29287119
Efficacy and safety of dronedarone: a review of randomized trials.
Christiansen, Christine Benn; Torp-Pedersen, Christian; Køber, Lars
2010-01-01
Dronedarone is developed for treatment of atrial fibrillation (AF) or flutter (AFL). It is a noniodinized amiodarone analogue and believed to be without the adverse effects of amiodarone. However, long-term adverse effects are not yet well investigated. This is a review of seven studies on dronedarone. DAFNE established an effective dose to be 400 mg b.i.d. ADONIS and EURIDIS showed significant prevention of AF/AFL recurrence hazard ratio (HR 0.78 and 0.73) compared to placebo. In ATHENA, cardiovascular death/hospitalization was significantly reduced (HR 0.76) in patients with AF and additional risk factors. ANDROMEDA was stopped because dronedarone increased early mortality (HR 2.13) in advanced heart failure (HF). ERATO found that dronedarone significantly reduced heart rate compared to placebo in patients with AF. DIONYSOS showed that amiodarone was superior to dronedarone to maintain sinus rhythm in patients with AF/AFL. Dronedarone is superior to placebo but less efficient than amiodarone in maintaining sinus rhythm in patients with a history of AF. In patients with AF and risk factors dronedarone reduces cardiovascular mortality and morbidity, but in patients with severe HF dronedarone significantly increases mortality.
NASA Astrophysics Data System (ADS)
Werner, J.; Hergett, W.; Gertig, M.; Park, J.; Koo, C.; Klingeler, R.
2017-06-01
Thermodynamic properties and low-energy magnon excitations of S =1 honeycomb-layered Na3Ni2SbO6 have been investigated by high-resolution dilatometry, static magnetization, and high-frequency electron spin resonance studies in magnetic fields up to 16 T. At TN = 16.5 K, there is a tricritical point separating two distinct antiferromagnetic phases, AF1 and AF2, from the paramagnetic regime. In addition, our data imply short-range antiferromagnetic correlations at least up to ˜5 TN . Well below TN, the magnetic field BC1≈9.5 T is needed to stabilize AF2 against AF1. The thermal expansion and magnetostriction anomalies at TN and BC 1 imply significant magnetoelastic coupling, both of which are associated with a sign change of ∂ L /∂ B . The transition at BC 1 is associated with softening of the antiferromagnetic resonance modes observed in the electron-spin-resonance spectra. The anisotropy gap Δ =360 GHz implies considerable uniaxial anisotropy. We deduce the crucial role of axial anisotropy favoring the AF1 spin structure over the AF2 one. While the magnetostriction data disprove a simple spin-flop scenario at BC 1, the nature of a second transition at BC 2 ≈ 13 T remains unclear. Both the sign of the magnetostriction and Grüneisen analysis suggest that the short-range correlations at high temperatures are of AF2 type.
Piccini, Jonathan P; Stevens, Susanna R; Lokhnygina, Yuliya; Patel, Manesh R; Halperin, Jonathan L; Singer, Daniel E; Hankey, Graeme J; Hacke, Werner; Becker, Richard C; Nessel, Christopher C; Mahaffey, Kenneth W; Fox, Keith A A; Califf, Robert M; Breithardt, Günter
2013-05-14
This study sought to investigate the outcomes following cardioversion or catheter ablation in patients with atrial fibrillation (AF) treated with warfarin or rivaroxaban. There are limited data on outcomes following cardioversion or catheter ablation in AF patients treated with factor Xa inhibitors. We compared the incidence of electrical cardioversion (ECV), pharmacologic cardioversion (PCV), or AF ablation and subsequent outcomes in patients in a post hoc analysis of the ROCKET AF (Efficacy and Safety Study of Rivaroxaban With Warfarin for the Prevention of Stroke and Non-Central Nervous System Systemic Embolism in Patients With Non-Valvular Atrial Fibrillation) trial. Over a median follow-up of 2.1 years, 143 patients underwent ECV, 142 underwent PCV, and 79 underwent catheter ablation. The overall incidence of ECV, PCV, or AF ablation was 1.45 per 100 patient-years (n = 321; 1.44 [n = 161] in the warfarin arm, 1.46 [n = 160] in the rivaroxaban arm). The crude rates of stroke and death increased in the first 30 days after cardioversion or ablation. After adjustment for baseline differences, the long-term incidence of stroke or systemic embolism (hazard ratio [HR]: 1.38; 95% confidence interval [CI]: 0.61 to 3.11), cardiovascular death (HR: 1.57; 95% CI: 0.69 to 3.55), and death from all causes (HR: 1.75; 95% CI: 0.90 to 3.42) were not different before and after cardioversion or AF ablation. Hospitalization increased after cardioversion or AF ablation (HR: 2.01; 95% CI: 1.51 to 2.68), but there was no evidence of a differential effect by randomized treatment (p value for interaction = 0.58). The incidence of stroke or systemic embolism (1.88% vs. 1.86%) and death (1.88% vs. 3.73%) were similar in the rivaroxaban-treated and warfarin-treated groups. Despite an increase in hospitalization, there were no differences in long-term stroke rates or survival following cardioversion or AF ablation. Outcomes were similar in patients treated with rivaroxaban or warfarin. (An Efficacy and Safety Study of Rivaroxaban With Warfarin for the Prevention of Stroke and Non-Central Nervous System Systemic Embolism in Patients With Non-Valvular Atrial Fibrillation [ROCKET AF]; NCT00403767). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Persistent Atrial Fibrillation Ablation using the Tip-Versatile Ablation Catheter.
Davies, Edward J; Clayton, Ben; Lines, Ian; Haywood, Guy A
2016-07-01
The mechanisms by which persistent atrial fibrillation (PsAF) develops are incompletely understood. Consequently, the optimal strategy for the ablative management of PsAF remains debated. Current methods are often time consuming, complex and non-reproducible. We assessed the Tip-Versatile Ablation Catheter (T-VAC) technique, a rapidly delivered, empirical technique based on the box-set concept using duty-cycled linear catheter ablation technology. Forty-four procedures in 40 patients undergoing PsAF ablation with the novel technique were prospectively entered onto a database: 27 de novo. Primary endpoint was freedom from arrhythmia at over two-year follow-up. Secondary endpoints were time to first arrhythmia recurrence, freedom from atrial fibrillation (AF) on and off antiarrhythmic drugs (AAD), procedural and fluoroscopy duration and complication rate. At mean follow-up of 33 months, absolute freedom from arrhythmia recurrence was 45% in the de novo group. Overall, at 33 (IQR 24-63) months, 60% of de novo patients were in sustained normal sinus rhythm and a further 15% reported only occasional paroxysms of AF at long-term follow-up. Procedure time was 192±25 mins, total energy delivered 2239±883s and fluoroscopy time was 60±10mins. In selected patients with persistent AF, a long-term rate of 60% arrhythmia free survival off AAD can be achieved using this novel T-VAC technique. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Scheimpflug with computational imaging to extend the depth of field of iris recognition systems
NASA Astrophysics Data System (ADS)
Sinharoy, Indranil
Despite the enormous success of iris recognition in close-range and well-regulated spaces for biometric authentication, it has hitherto failed to gain wide-scale adoption in less controlled, public environments. The problem arises from a limitation in imaging called the depth of field (DOF): the limited range of distances beyond which subjects appear blurry in the image. The loss of spatial details in the iris image outside the small DOF limits the iris image capture to a small volume-the capture volume. Existing techniques to extend the capture volume are usually expensive, computationally intensive, or afflicted by noise. Is there a way to combine the classical Scheimpflug principle with the modern computational imaging techniques to extend the capture volume? The solution we found is, surprisingly, simple; yet, it provides several key advantages over existing approaches. Our method, called Angular Focus Stacking (AFS), consists of capturing a set of images while rotating the lens, followed by registration, and blending of the in-focus regions from the images in the stack. The theoretical underpinnings of AFS arose from a pair of new and general imaging models we developed for Scheimpflug imaging that directly incorporates the pupil parameters. The model revealed that we could register the images in the stack analytically if we pivot the lens at the center of its entrance pupil, rendering the registration process exact. Additionally, we found that a specific lens design further reduces the complexity of image registration making AFS suitable for real-time performance. We have demonstrated up to an order of magnitude improvement in the axial capture volume over conventional image capture without sacrificing optical resolution and signal-to-noise ratio. The total time required for capturing the set of images for AFS is less than the time needed for a single-exposure, conventional image for the same DOF and brightness level. The net reduction in capture time can significantly relax the constraints on subject movement during iris acquisition, making it less restrictive.
Long-time dynamic compatibility of elastomeric materials with hydrazine
NASA Technical Reports Server (NTRS)
Coulbert, C. D.; Cuddihy, E. F.; Fedors, R. F.
1973-01-01
The tensile property surfaces for two elastomeric materials, EPT-10 and AF-E-332, were generated in air and in liquid hydrazine environments using constant strain rate tensile tests over a range of temperatures and elongation rates. These results were used to predict the time-to-rupture for these materials in hydrazine as a function of temperature and amount of strain covering a span of operating times from less than a minute to twenty years. The results of limited sheet-folding tests and their relationship to the tensile failure boundary are presented and discussed.
Ablation for Atrial Fibrillation
2006-01-01
Executive Summary Objective To review the effectiveness, safety, and costing of ablation methods to manage atrial fibrillation (AF). The ablation methods reviewed were catheter ablation and surgical ablation. Clinical Need Atrial fibrillation is characterized by an irregular, usually rapid, heart rate that limits the ability of the atria to pump blood effectively to the ventricles. Atrial fibrillation can be a primary diagnosis or it may be associated with other diseases, such as high blood pressure, abnormal heart muscle function, chronic lung diseases, and coronary heart disease. The most common symptom of AF is palpitations. Symptoms caused by decreased blood flow include dizziness, fatigue, and shortness of breath. Some patients with AF do not experience any symptoms. According to United States data, the incidence of AF increases with age, with a prevalence of 1 per 200 people aged between 50 and 60 years, and 1 per 10 people aged over 80 years. In 2004, the Institute for Clinical Evaluative Sciences (ICES) estimated that the rate of hospitalization for AF in Canada was 582.7 per 100,000 population. They also reported that of the patients discharged alive, 2.7% were readmitted within 1 year for stroke. One United States prevalence study of AF indicated that the overall prevalence of AF was 0.95%. When the results of this study were extrapolated to the population of Ontario, the prevalence of AF in Ontario is 98,758 for residents aged over 20 years. Currently, the first-line therapy for AF is medical therapy with antiarrhythmic drugs (AADs). There are several AADs available, because there is no one AAD that is effective for all patients. The AADs have critical adverse effects that can aggravate existing arrhythmias. The drug selection process frequently involves trial and error until the patient’s symptoms subside. The Technology Ablation has been frequently described as a “cure” for AF, compared with drug therapy, which controls AF but does not cure it. Ablation involves directing an energy source at cardiac tissue. For instance, radiofrequency energy uses heat to burn tissue near the source of the arrhythmia. The purpose is to create a series of scar tissue, so that the aberrant electrical pathways can no longer exist. Because the pulmonary veins are the predominant source of AF initiation, the primary goal of ablation is to isolate the pulmonary veins from the left atria through the creation of a conduction block. There are 2 methods of ablation: catheter ablation and surgical (operative) ablation. Radiofrequency energy is most commonly used for ablation. Catheter ablation involves inserting a catheter through the femoral vein to access the heart and burn abnormal foci of electrical activity by direct contact or by isolating them from the rest of the atrium. The surgical ablation is performed minimally invasively via direct visualization or with the assistance of a special scope for patients with lone AF. Review Strategy In March 2006, the following databases were searched: Cochrane Library International Agency for Health Technology Assessment (first quarter 2006), Cochrane Database of Systematic Reviews (first quarter 2006), Cochrane Central Register of Controlled Trials (first quarter 2006), MEDLINE (1966 to February 2006), MEDLINE In-Process and Other Non-indexed Citations (1966 to March 1, 2006), and EMBASE (1980 to 2006 week 9). The Medical Advisory Secretariat also searched Medscape on the Internet for recent reports on trials that were unpublished but that were presented at international conferences. In addition, the Web site Current Controlled Trials (www.controlled-trials.com) was searched for ongoing trials investigating ablation for atrial fibrillation. Search terms included: radiofrequency ablation, catheter ablation and atrial fibrillation. Summary of Findings Sixteen RCTs were identified that compared ablation methods in patients with AF. Two studies were identified that investigated first-line therapy for AF or atrial flutter. Seven other studies examined patients with drug-refractory, lone AF; and the remaining 7 RCTs compared ablation plus heart surgery to heart surgery alone in patients with drug-refractory AF and concomitant heart conditions. First-line Catheter Ablation for Atrial Fibrillation or Atrial Flutter Both studies concluded that catheter ablation was associated with significantly improved long-term freedom from arrhythmias and quality of life compared with medical therapy. These studies included different patient populations (those with AF in one pilot study, and those with atrial flutter in the other). Catheter ablation as first-line treatment is considered experimental at this time. Catheter Ablation Versus Medical Therapy in Patients With Drug-Refractory, Lone Atrial Fibrillation In this review, catheter ablation had success rates (freedom from arrhythmia) that ranged from 42% to 90% (median, 74%) in patients with drug-refractory, lone AF. All 3 of the RCTs comparing catheter ablation to medical therapy in patients with drug-refractory, lone AF found a significant improvement in terms of freedom from arrhythmia over a minimum of 12 months follow-up (P<.05). Ablation Plus Heart Surgery Versus Heart Surgery Alone in Patients With Atrial Fibrillation It is clear that patients with drug-refractory AF who are undergoing concomitant heart surgery (usually mitral valve repair or replacement) benefit significantly from surgical ablation, in terms of long-term freedom from AF, without substantial additional risk compared to open heart surgery alone. This group of patients represents about 1% of the patients with atrial fibrillation, thus the majority of the burden of AF lies within the patients with lone AF (i.e. those not requiring additional heart surgery). Conclusion Catheter ablation appears to be an effective treatment for patients with drug-refractory AF whose treatment alternatives are limited. Ablation technology is continually evolving with increasing success rates associated with the ablation procedure. PMID:23074498
NASA Astrophysics Data System (ADS)
Middlemiss, Derek S.; Lawton, Lorreta M.; Wilson, Chick C.
2008-08-01
The variations with pressure in the structural, electronic and magnetic properties of a series of Prussian blue analogues (PBAs) KIMII[CrIII(CN)6] (M = VII, MnII and NiII) and associated isomorphous chlorides KIMIICrIIICl6 are investigated within a series of solid-state hybrid density functional calculations. The sensitivity of the computed properties to the choice of Hamiltonian is tested by application of functionals containing 35%, 65% and 100% admixtures of Fock exchange. Magnetic coupling constants (J) are obtained at a range of cell volumes (V), with fits of the Bloch relationship (J \\propto V^{-\\varepsilon } , ɛ typically 3-4) yielding exponents ɛ in the ranges 5.16-6.34, 8.48-12.07 and 4.00-4.51 for the antiferromagnetic (AF) VIICrIII-, ferrimagnetic (FI) MnIICrIII- and ferromagnetic (FO) NiIICrIII PBAs, respectively; and 3.33-4.99, 1.86-3.09 and 1.65-3.28 for the AF VIICrIII-, FO MnIICrIII- and FO NiIICrIII chlorides, respectively. The MnIICrIII PBA range encloses the high values ɛ~9-10 obtained in a recent joint experimental and theoretical study, and it is suggested that this strong magnetostructural effect arises due to the presence of competing AF and FO interactions in this material. Estimates of the spin ordering temperatures derived from the combination of the 35%-functional couplings with a mean field approach are in good agreement with experiment in the VIICrIII and NiIICrIII PBAs, but are too low in the MnIICrIII system. The variations with pressure in the structural parameters, charges and spin moments are also detailed, the PBA and chloride energy-volume data yielding bulk moduli in the ranges 39-53 and 36-50 GPa, respectively. Finally, the energies governing CN- ligand isomerization are estimated and successfully interpreted in terms of a simple crystal field stabilization model.
Absorption and emission spectroscopic characterisation of 8-amino-riboflavin
NASA Astrophysics Data System (ADS)
Tyagi, A.; Zirak, P.; Penzkofer, A.; Mathes, T.; Hegemann, P.; Mack, M.; Ghisla, S.
2009-10-01
The flavin dye 8-amino-8-demethyl- D-riboflavin (AF) in the solvents water, DMSO, methanol, and chloroform/DMSO was studied by absorption and fluorescence spectroscopy. The first absorption band is red-shifted compared to riboflavin, and blue-shifted compared to roseoflavin (8-dimethylamino-8-demethyl-D-riboflavin). The fluorescence quantum yield of AF in the studied solvents varies between 20% and 50%. The fluorescence lifetimes were found to be in the 2-5 ns range. AF is well soluble in DMSO, weakly soluble in water and methanol, and practically insoluble in chloroform. The limited solubility causes AF aggregation, which was seen in differences between measured absorption spectra and fluorescence excitation spectra. Light scattering in the dye absorption region is discussed and approximate absorption cross-section spectra are determined from the combined measurement of transmission and fluorescence excitation spectra. The photo-stability of AF was studied by prolonged light exposure. The photo-degradation routes of AF are discussed.
Antiferromagnetic Ordering in Organic Conductor λ-(BEDT-TTF)2GaCl4 Probed by 13C NMR
NASA Astrophysics Data System (ADS)
Saito, Yohei; Fukuoka, Shuhei; Kobayashi, Takuya; Kawamoto, Atsushi; Mori, Hatsumi
2018-01-01
The ground state of λ-(BEDT-TTF)2GaCl4, which has the same structure as the organic superconductor λ-(BETS)2GaCl4, was investigated by magnetic susceptibility and 13C NMR measurements. The temperature dependence of the magnetic susceptibility revealed an antiferromagnetic (AF) correlation with J/kB ≃ 98 K. NMR spectrum splitting and the divergence of 1/T1 were observed at approximately 13 K, which is associated with the AF transition. We found that the AF structure is commensurate according to discrete NMR peak splitting, suggesting that the ground state of λ-(BEDT-TTF)2GaCl4 is an AF dimer-Mott insulating state. Our results suggest that the superconducting phase of λ-type salts would be located near the AF insulating phase.
Characterization of AFLAV, a Tf1/Sushi retrotransposon from Aspergillus flavus.
Hua, Sui-Sheng T; Tarun, Alice S; Pandey, Sonal N; Chang, Leo; Chang, Perng-Kuang
2007-02-01
The plasmid, pAF28, a genomic clone from Aspergillus flavus NRRL 6541, has been used as a hybridization probe to fingerprint A. flavus strains isolated in corn and peanut fields. The insert of pAF28 contains a 4.5 kb region which encodes a truncated retrotransposon (AfRTL-1). In search for a full-length and intact copy of retrotransposon, we exploited a novel PCR cloning strategy by amplifying a 3.4 kb region from the genomic DNA of A. flavus NRRL 6541. The fragment was cloned into pCR 4-TOPO. Sequence analysis confirmed that this region encoded putative domains of partial reverse transcriptase, RNase H, and integrase of the predicted retrotransposon. The two flanking long terminal repeats (LTRs) and the sequence between them comprise a putative full-length LTR retrotransposon of 7799 bp in length. This intact retrotransposon sequence is named AFLAV (A. flavus Retrotransposon). The order of the predicted catalytic domains in the polyprotein (Pol) placed AFLAV in the Tf1/sushi subgroup of the Ty3/gypsy retrotransposon family. Primers derived from AFLAV sequence were used to screen this retrotransposon in other strains of A. flavus. More than fifty strains of A. flavus isolated from different geological origins were surveyed and the results show that many strains have extensive deletions in the regions encoding the capsid (Gag) and Pol.
Atrial Fibrillation in Athletes: A Lesson in the Virtue of Moderation.
Estes, N A Mark; Madias, Christopher
2017-09-01
Although the cardiovascular benefits of moderate exercise are well established, there is growing epidemiological support for the notion that high-intensity endurance athletics increases the risk of atrial fibrillation (AF). There are many gaps in evidence related to epidemiology and mechanisms of AF in endurance athletes. The proposed pathophysiological mechanisms include alterations of autonomic tone, electrical remodeling, anatomical remodeling, fibrosis, and inflammation. Clinical management of the athlete with AF often includes a period of decreased frequency, intensity, and duration of exercise with assessment for improvement in AF recurrence. Based on symptoms, a strategy of rate or rhythm control should be selected; however, due to side effects and intolerance of medications, ablation may be a preferred approach. The risks and benefits of anticoagulation for stroke prevention must be carefully assessed in the athlete with AF. All patients should be encouraged to be physically active with moderation; however, men should be advised of the higher risk of AF with long-term, high-intensity endurance training. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Remote magnetic navigation in atrial fibrillation.
Szili-Torok, Tamas; Akca, Ferdi
2012-05-01
Atrial fibrillation (AF) is of profound public health importance and is largely a disease of aging and is responsible for increased morbidity- and mortality-related healthcare expenditures. Catheter ablation to isolate the pulmonary veins has become the therapy of choice for treatment of drug-refractory AF. Procedures can be very challenging and multiple difficulties must be overcome in order to achieve a successful outcome. The magnetic navigation system (MNS) has advantages in catheter maneuverability, stability and reproducibility. Due to the catheter design safety and efficacy of AF, ablation has increased. New developments are being made to allow fully remote ablation procedures in combination with the MNS. However, new technologies are still necessary to improve MNS ablation for AF.
Omura, Yoshiaki; Lu, Dominic; Jones, Marilyn K; Nihrane, Abdallah; Duvvi, Harsha; Yapor, Dario; Shimotsuura, Yasuhiro; Ohki, Motomu
2015-01-01
Lyme disease is found in a majority of people we tested. Once Borrelia Burgdorferi (B.B.) spirochete enters human body, it not only causes pain by infecting joints, but it also often enters the brain and the heart. Infection of brain can be quickly detected from the pupil and infection of the heart by ECGs non-invasively. By evaluating recorded ECGs of atrial fibrillation (AF), using U.S. patented non-invasive highly sensitive electromagnetic field (EMF) resonance phenomenon between 2 identical molecules or between a molecule and its antibody, we examined 25 different AF patients' ECGs and found the majority of them suffer from various degrees of B.B. spirochete infection in SA node areas, also in the right & left atria, and pulmonary vein near and around its junction at left atrium & lesser degrees of infection at the AV node & His Bundle. When B.B. infection reaches over 224-600ng or higher at these areas, AF often appears in the majority of all AF analyzed. In order to develop AF, the 4 abnormal factors must be present simultaneously: 1) B.B. infection must be increased to 224-600ng or higher, 2) Atrial Natriuretic Peptide (ANP) must be markedly reduced from normal value of less than 4ng to over 100-400ng, 3) A significant increase of Cardiac Troponin I from normal value of less than 3ng to over 12ng and 4) Taurine must also be markedly reduced from normal value of 4-6ng to 0.25ng. These 4 changes were mainly found only at infected sites of the SA node area, both atria and between the end of the T wave & the beginning of the SA node area, which corresponds to U waves at recorded ECG. Origin of the U wave is mainly due to abnormal electrical potential of pulmonary vein at L-atrium. If all 4 factors do not occur at the infection site, no AF will develop. In seemingly normal ECGs, if using this method, one can detect invisible B.B. infection in early stages. Long before AF appears, AF can be prevented by improved treatment with Amoxicillin 500ng 3 times/day + Taurine 175mg x 3 times/day, with or without EPA 180 mg & DHA 120 mg, to avoid serious current limitations in the use of Doxycycline 100 mg 2 times/day, for 4 weeks.
Atrial Fibrillation Genetic Risk and Ischemic Stroke Mechanisms.
Lubitz, Steven A; Parsons, Owen E; Anderson, Christopher D; Benjamin, Emelia J; Malik, Rainer; Weng, Lu-Chen; Dichgans, Martin; Sudlow, Cathie L; Rothwell, Peter M; Rosand, Jonathan; Ellinor, Patrick T; Markus, Hugh S; Traylor, Matthew
2017-06-01
Atrial fibrillation (AF) is a leading cause of cardioembolic stroke, but the relationship between AF and noncardioembolic stroke subtypes are unclear. Because AF may be unrecognized, and because AF has a substantial genetic basis, we assessed for predisposition to AF across ischemic stroke subtypes. We examined associations between AF genetic risk and Trial of Org 10172 in Acute Stroke Treatment stroke subtypes in 2374 ambulatory individuals with ischemic stroke and 5175 without from the Wellcome Trust Case-Control Consortium 2 using logistic regression. We calculated AF genetic risk scores using single-nucleotide polymorphisms associated with AF in a previous independent analysis across a range of preselected significance thresholds. There were 460 (19.4%) individuals with cardioembolic stroke, 498 (21.0%) with large vessel, 474 (20.0%) with small vessel, and 814 (32.3%) individuals with strokes of undetermined cause. Most AF genetic risk scores were associated with stroke, with the strongest association ( P =6×10 - 4 ) attributed to scores of 944 single-nucleotide polymorphisms (each associated with AF at P <1×10 - 3 in a previous analysis). Associations between AF genetic risk and stroke were enriched in the cardioembolic stroke subset (strongest P =1.2×10 - 9 , 944 single-nucleotide polymorphism score). In contrast, AF genetic risk was not significantly associated with noncardioembolic stroke subtypes. Comprehensive AF genetic risk scores were specific for cardioembolic stroke. Incomplete workups and subtype misclassification may have limited the power to detect associations with strokes of undetermined pathogenesis. Future studies are warranted to determine whether AF genetic risk is a useful biomarker to enhance clinical discrimination of stroke pathogeneses. © 2017 American Heart Association, Inc.
Siontis, Konstantinos C.; Geske, Jeffrey B.; Ong, Kevin; Nishimura, Rick A.; Ommen, Steve R.; Gersh, Bernard J.
2014-01-01
Background Atrial fibrillation (AF) is a common sequela of hypertrophic cardiomyopathy (HCM), but evidence on its prevalence, risk factors, and effect on mortality is sparse. We sought to evaluate the prevalence of AF, identify clinical and echocardiographic correlates, and assess its effect on mortality in a large high‐risk HCM population. Methods and Results We identified HCM patients who underwent evaluation at our institution from 1975 to 2012. AF was defined by known history (either chronic or paroxysmal), electrocardiogram, or Holter monitoring at index visit. We examined clinical and echocardiographic variables in association with AF. The effect of AF on overall and cause‐specific mortality was evaluated with multivariate Cox proportional hazards models. Of 3673 patients with HCM, 650 (18%) had AF. Patients with AF were older and more symptomatic (P<0.001). AF was less common among patients with obstructive HCM phenotype and was associated with larger left atria, higher E/e’ ratios, and worse cardiopulmonary exercise tolerance (all P values<0.001). During median (interquartile range) follow‐up of 4.1 (0.2 to 10) years, 1069 (29%) patients died. Patients with AF had worse survival compared to those without AF (P<0.001). In multivariate analysis adjusted for established risk factors of mortality in HCM, the hazard ratio (95% confidence interval) for the effect of AF on overall mortality was 1.48 (1.27 to 1.71). AF did not have an effect on sudden or nonsudden cardiac death. Conclusions In this large referral HCM population, approximately 1 in 5 patients had AF. AF was a strong predictor of mortality, even after adjustment for established risk factors. PMID:24965028
Steinberg, Benjamin A.; Hellkamp, Anne S.; Lokhnygina, Yuliya; Patel, Manesh R.; Breithardt, Günter; Hankey, Graeme J.; Becker, Richard C.; Singer, Daniel E.; Halperin, Jonathan L.; Hacke, Werner; Nessel, Christopher C.; Berkowitz, Scott D.; Mahaffey, Kenneth W.; Fox, Keith A.A.; Califf, Robert M.; Piccini, Jonathan P.
2015-01-01
Aim Anticoagulation prophylaxis for stroke is recommended for at-risk patients with either persistent or paroxysmal atrial fibrillation (AF). We compared outcomes in patients with persistent vs. paroxysmal AF receiving oral anticoagulation. Methods and results Patients randomized in the Rivaroxaban Once Daily Oral Direct Factor Xa Inhibition Compared With Vitamin K Antagonism for Prevention of Stroke and Embolism Trial in Atrial Fibrillation (ROCKET-AF) trial (n = 14 264) were grouped by baseline AF category: paroxysmal or persistent. Multivariable adjustment was performed to compare thrombo-embolic events, bleeding, and death between groups, in high-risk subgroups, and across treatment assignment (rivaroxaban or warfarin). Of 14 062 patients, 11 548 (82%) had persistent AF and 2514 (18%) had paroxysmal AF. Patients with persistent AF were marginally older (73 vs. 72, P = 0.03), less likely female (39 vs. 45%, P < 0.0001), and more likely to have previously used vitamin K antagonists (64 vs. 56%, P < 0.0001) compared with patients with paroxysmal AF. In patients randomized to warfarin, time in therapeutic range was similar (58 vs. 57%, P = 0.94). Patients with persistent AF had higher adjusted rates of stroke or systemic embolism (2.18 vs. 1.73 events per 100-patient-years, P = 0.048) and all-cause mortality (4.78 vs. 3.52, P = 0.006). Rates of major bleeding were similar (3.55 vs. 3.31, P = 0.77). Rates of stroke or systemic embolism in both types of AF did not differ by treatment assignment (rivaroxaban vs. warfarin, Pinteraction = 0.6). Conclusion In patients with AF at moderate-to-high risk of stroke receiving anticoagulation, those with persistent AF have a higher risk of thrombo-embolic events and worse survival compared with paroxysmal AF. PMID:25209598
Late outcomes after the Cox maze IV procedure for atrial fibrillation.
Henn, Matthew C; Lancaster, Timothy S; Miller, Jacob R; Sinn, Laurie A; Schuessler, Richard B; Moon, Marc R; Melby, Spencer J; Maniar, Hersh S; Damiano, Ralph J
2015-11-01
The Cox maze IV procedure (CMPIV) has been established as the gold standard for surgical ablation; however, late outcomes using current consensus definitions of treatment failure have not been well described. To compare to reported outcomes of catheter-based ablation, we report our institutional outcomes of patients who underwent a left-sided or biatrial CMPIV at 5 years of follow-up. Between January 2002 and September 2014, data were collected prospectively on 576 patients with AF who underwent a CMPIV (n = 532) or left-sided CMPIV (n = 44). Perioperative variables and long-term freedom from AF, with and without AADs, were compared in multiple subgroups. Follow-up at any time point was 89%. At 5 years, overall freedom from AF was 93 of 119 (78%), and freedom from AF off AADs was 77 of 177 (66%). No differences were found in freedom from AF, with or without AADs, at 1, 2, 3, 4, and 5 years for patients with paroxysmal AF (n = 204) versus with persistent/longstanding persistent AF (n = 305), or for those who underwent standalone versus a concomitant CMP. Duration of preoperative AF and hospital length of stay were the best predictors of failure at 5 years. The outcomes of the CMPIV remain good at late follow-up. The type of preoperative AF or the addition of a concomitant procedure did not affect late success. The results of the CMPIV remain superior to those reported for catheter ablation and other forms of surgical AF ablation, especially for patients with persistent or longstanding AF. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Liao, Ying-Chieh; Liao, Jo-Nan; Lo, Li-Wei; Lin, Yenn-Jiang; Chang, Shih-Lin; Hu, Yu-Feng; Chao, Tze-Fan; Chung, Fa-Po; Tuan, Ta-Chuan; Te, Abigail Louise D; Walia, Rohit; Yamada, Shinya; Lin, Chung-Hsing; Lin, Chin-Yu; Chang, Yao-Ting; Allamsetty, Suresh; Yu, Wen-Chung; Huang, Jing-Long; Wu, Tsu-Juey; Chen, Shih-Ann
2017-01-01
Although rare, some paroxysmal atrial fibrillations (AF) still progress despite radiofrequency (RF) ablation. In the study, we evaluated the long-term efficacy of RF ablation and the predictors of AF progression. A total of 589 paroxysmal AF patients (404 men and 185 women; aged 54 ± 12 years) who received 3-dimensional mapping and ablation were enrolled. Their clinical parameters and electrophysiological characteristics were collected. They were divided into Group 1 (N = 13, with AF progression) and Group 2 (N = 576, no AF progression). AF progression was defined as recurrence of persistent AF. Group 1 patients had larger left atrial (LA) diameter, larger left ventricle (LV) end-systolic and end-diastolic diameters, poorer LV systolic function, and more amiodarone use at baseline. After 1.2 ± 0.5 procedures, 123 (21%) patients experienced recurrence during 56 ± 29 months' follow-up. In the multivariate analysis, LA diameter (P = 0.018, HR = 1.12, 95% CI = 1.02-1.24) and LV end-systolic diameter (P = 0.005, HR = 1.10, 95% CI = 1.03-1.17) independently predicted AF progression. LA diameter >43 mm and LV end-systolic diameter >31 mm were the best cut-off values for predicting AF progression by ROC analysis. AF progression rate achieved 19% if they had both larger LA diameter (>43 mm) and LV end-systolic diameter (>31 mm). RF ablation prevents the progression of paroxysmal AF effectively, except in patients with increased LA diameter and LV end-systolic diameter on echocardiogram, suggesting more aggressive rhythm control therapies should be considered in these patients. © 2016 Wiley Periodicals, Inc.
Reyes, Guillermo; Ruyra, Xavier; Valderrama, Francisco; Jimenez, Antonio; Duran, Dario; Perez, Enrique; Daroca, Tomas; Moya, Javier; Ramirez, Ulises; Aldamiz, Gonzalo
2016-10-01
A National Spanish Registry to compile all patients treated with high intensity focused ultrasound (HIFU) energy for atrial fibrillation (AF) was created to evaluate the safety and efficacy of AF surgical ablation. A national Spanish registry was created, and ten hospitals using HIFU to ablate AF joined it. A total of 412 patients undergoing cardiac surgery between 2006 and February 2013 were included. AF was divided between paroxysmal AF (33%) and persistent AF (67%) with a mean AF duration of 29.3±108.2 months. Mean left atrial diameter was 51.2±6.5 mm. Mean underlying heart disease were aortic valve disease (49.3%), ischemic disease (25.2%) and mitral disease (33.2%) Clinical follow-up of patients and a 6 months postoperative echocardiogram were performed in all patients. A pacemaker implantation was needed in 4.9% of patients with a perioperative stroke in 2.5%. Rhythm at discharge from hospital was sinus rhythm in 58%, AF in 35.9% and atrial flutter in 0.8% of patients. Sinus rhythm restoration at 6, 12, 24 and 36 months follow-up was achieved in 66.1%, 63.8%, 63.9% and 45.9% of patients respectively. Multivariate analysis showed paroxysmal AF and sinus rhythm restoration in the operating theatre as factors related to sinus rhythm long term restoration. The Spanish national registry showed an efficacy of AF ablation with the HIFU Epicor system of 66.1%, 63.8%, 63.9% and 45.9% at 6, 12, 24 and 36 months follow-up. There were no device-related complications.
General relaxation schemes in multigrid algorithms for higher order singularity methods
NASA Technical Reports Server (NTRS)
Oskam, B.; Fray, J. M. J.
1981-01-01
Relaxation schemes based on approximate and incomplete factorization technique (AF) are described. The AF schemes allow construction of a fast multigrid method for solving integral equations of the second and first kind. The smoothing factors for integral equations of the first kind, and comparison with similar results from the second kind of equations are a novel item. Application of the MD algorithm shows convergence to the level of truncation error of a second order accurate panel method.
Mina, Adel F; Warnecke, Nicholas L
2016-01-01
Background: Pulmonary Vein Antral isolation (PVAI) is currently the standard of care for both paroxysmal and persistent atrial fibrillation ablation. Reconnection to the pulmonary vein is the most common cause of recurrence of atrial fibrillation. Achieving the endpoint of bidirectional block (BDB) for cavotricuspid isthmus dependant flutter has improved our outcomes for atrial flutter ablation. With this we tried to achieve long delays in the pulmonary veins antral lines prior to complete isolation comparable to those delays found in patient with bidirectional block of atrial flutter lines. Study Objective: The objective of this paper was to evaluate feasibility and efficacy of achieving Bidirectional long delays in pulmonary vein antral lines prior to Bidirectional Block in patient with paroxysmal atrial fibrillation. Method: A retrospective analysis was performed on patients who had paroxysmal atrial fibrillation procedures at Unity Point Methodist from January 2015 to January 2016. 20 consecutive patients with paroxysmal atrial fibrillation who had AF ablation using the Bi-Bi technique were evaluated. Result: Mean age was 63, number of antiarrhythmic used prior to ablation was 1.4, mean left atrial size was 38 mm. Mean chads score was 1.3. Mean EF was 53%. Long delays in the left antral circumferential lines were achieved with mean delay of 142 milliseconds +/-100. Also long delays in the right antral circumferential lines were achieved with mean delay of 150 milliseconds +/-80. 95 % (19/20) of patients were free of any atrial arrhythmias and were off antiarrhythmic medications for AF post procedure. There was only one transient complication in one patient who developed a moderate pericardial effusion that was successfully drained with no hemodynamic changes. The only patient who had recurrence was found to have asymptomatic AF with burden on his device <1%, this patient was also found to have non PV triggers for his AF. In patients with only PV triggered AF success rate was 100%. Conclusion: Achievement of Bidirectional long delays in pulmonary vein antral lines prior to Bidirectional Block in patient with paroxysmal atrial fibrillation is feasible and highly effective technique in this small cohort of patients studied. We also outlined the procedure in details.
Acute effects of muscle vibration on sensorimotor integration.
Lapole, Thomas; Tindel, Jérémy
2015-02-05
Projections from the somesthetic cortex are believed to be involved in the modulation of motor cortical excitability by muscle vibration. The aim of the present pilot study was to analyse the effects of a vibration intervention on short-latency afferent inhibition (SAI), long-latency afferent inhibition (LAI), and afferent facilitation (AF), three intracortical mechanisms reflecting sensorimotor integration. Abductor pollicis brevis (APB) SAI, AF and LAI were investigated on 10 subjects by conditioning test transcranial magnetic stimulation pulses with median nerve electrical stimulation at inter-stimuli intervals in the range 15-25 ms, 25-60 ms, and 100-200 ms, respectively. Test motor evoked potentials (MEPs) were compared to unconditioned MEPs. Measurements were performed before and just after 15 min of vibration applied to the muscle belly of APB at a frequency of 80 Hz. SAI and LAI responses were significantly reduced compared to unconditioned test MEPs (P=0.039 and P<0.001, respectively). AF MEP amplitude was greater than SAI and LAI one (P=0.009 and P=0.004, respectively), but not different from test MEP (P=0.511). There was no significant main effect of vibration (P=0.905). However, 4 subjects were clearly identified as responders. Their mean vibration-induced increase was 324 ± 195% in APB SAI MEP amplitude, and 158 ± 53% and 319 ± 80% in AF and LAI, respectively. Significant differences in SAI, AF and LAI vibration-induced changes were found for responders when compared to non-responders (P=0.019, P=0.038, and P=0.01, respectively). A single session of APB vibration may increase sensorimotor integration, via decreased inhibition and increased facilitation. However, such results were not observed for all subjects, suggesting that other factors (such as attention to the sensory inputs) may have played a role. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Soliman, Elsayed Z.; Prineas, Ronald J.; Case, L. Douglas; Zhang, Zhu-ming; Goff, David C.
2009-01-01
Background and Purpose The paradox of the reported low prevalence of atrial fibrillation (AF) in blacks compared with whites despite higher stroke rates in the former could be related to limitations in the current methods used to diagnose AF in population-based studies. Hence, this study aimed to use the ethnic distribution of ECG predictors of AF as measures of AF propensity in different ethnic groups. Methods The distribution of baseline measures of P-wave terminal force, P-wave duration, P-wave area, and PR duration (referred to as AF predictors) were compared by ethnicity in 15 429 participants (27% black) from the Atherosclerosis Risk in Communities (ARIC) study by unpaired t test, χ2, and logistic-regression analysis, as appropriate. Cox proportional-hazards analysis was used to separately examine the association of AF predictors with incident AF and ischemic stroke. Results Whereas AF was significantly less common in blacks compared with whites (0.24% vs 0.95%, P<0.0001), similar to what has been reported in previous studies, blacks had significantly higher and more abnormal values of AF predictors (P<0.0001 for all comparisons). Black ethnicity was significantly associated with abnormal AF predictors compared with whites; odds ratios for different AF predictors ranged from 2.1 to 3.1. AF predictors were significantly and independently associated with AF and ischemic stroke with no significant interaction between ethnicity and AF predictors, findings that further justify using AF predictors as an earlier indicator of future risk of AF and stroke. Conclusions There is a disconnect between the ethnic distribution of AF predictors and the ethnic distribution of AF, probably because the former, unlike the latter, do not suffer from low sensitivity. These results raise the possibility that blacks might actually have a higher prevalence of AF that might have been missed by previous studies owing to limited methodology, a difference that could partially explain the greater stroke risk in blacks. PMID:19213946
Omboni, Stefano; Verberk, Willem J
2016-04-12
Timely detection of atrial fibrillation (AF) may effectively prevent cardiovascular consequences. However, traditional diagnostic tools are either poorly reliable (pulse palpation) or not readily accessible (ECG) in general practice. We tested whether an automatic oscillometric blood pressure (BP) monitor embedded with an algorithm for AF detection might be effective for opportunistic screening of asymptomatic AF in the community. A community-based screening campaign in an unselected population to verify the feasibility of AF screening with a Microlife WatchBP Office BP monitor with a patented AFIB algorithm. When possible AF was detected (≥2 of 3 BP measurements reporting AF), a doctor immediately performed a single-lead ECG in order to confirm or exclude the presence of the arrhythmia. The main demographic and clinical data were also collected. 220 consecutive participants from an unselected sample of individuals in a small Italian community. Number of patients detected with AF and diagnosed risk factors for AF. In 12 of 220 participants, the device detected possible AF during the BP measurement: in 4 of them (1.8%), the arrhythmia was confirmed by the ECG. Patients with AF were more likely to be older (77.0±1.2 vs 57.2±15.2 years, p=0.010), obese (50.0 vs 14.4%, p=0.048) and to suffer from a cardiovascular disease (50.0 vs 10.6%, p=0.014) than patients without AF. Participants with a positive BP AF reading and non-AF arrhythmias (n=8) did not differ in their general characteristics from participants with a negative BP AF reading and were younger than patients with AF (mean age 56.4±14.8, p=0.027; 5 of 8 participants aged <65 years). Opportunistic screening of AF by BP measurement is feasible to diagnose this arrhythmia in unaware participants, particularly in those older than 65 years, who are the target patient group recommended by current AF screening guidelines. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Tam, David W.; Song, Yu; Man, Haoran; ...
2017-02-17
In this paper, we use neutron diffraction and muon spin relaxation to study the effect of in-plane uniaxial pressure on the antiferromagnetic (AF) orthorhombic phase in BaFe 2As 2 and its Co- and Ni-substituted members near optimal superconductivity. In the low-temperature AF ordered state, uniaxial pressure necessary to detwin the orthorhombic crystals also increases the magnetic ordered moment, reaching an 11% increase under 40 MPa for BaFe 1.9Co 0.1As 2, and a 15% increase for BaFe 1.915Ni 0.085As 2. We also observe an increase of the AF ordering temperature (T N) of about 0.25 K/MPa in all compounds, consistent withmore » density functional theory calculations that reveal better Fermi surface nesting for itinerant electrons under uniaxial pressure. Finally, the doping dependence of the magnetic ordered moment is captured by combining dynamical mean field theory with density functional theory, suggesting that the pressure-induced moment increase near optimal superconductivity is closely related to quantum fluctuations and the nearby electronic nematic phase.« less
The burden of proof: The current state of atrial fibrillation prevention and treatment trials.
Zakeri, Rosita; Van Wagoner, David R; Calkins, Hugh; Wong, Tom; Ross, Heather M; Heist, E Kevin; Meyer, Timothy E; Kowey, Peter R; Mentz, Robert J; Cleland, John G; Pitt, Bertram; Zannad, Faiez; Linde, Cecilia
2017-05-01
Atrial fibrillation (AF) is an age-related arrhythmia of enormous socioeconomic significance. In recent years, our understanding of the basic mechanisms that initiate and perpetuate AF has evolved rapidly, catheter ablation of AF has progressed from concept to reality, and recent studies suggest lifestyle modification may help prevent AF recurrence. Emerging developments in genetics, imaging, and informatics also present new opportunities for personalized care. However, considerable challenges remain. These include a paucity of studies examining AF prevention, modest efficacy of existing antiarrhythmic therapies, diverse ablation technologies and practice, and limited evidence to guide management of high-risk patients with multiple comorbidities. Studies examining the long-term effects of AF catheter ablation on morbidity and mortality outcomes are not yet completed. In many ways, further progress in the field is heavily contingent on the feasibility, capacity, and efficiency of clinical trials to incorporate the rapidly evolving knowledge base and to provide substantive evidence for novel AF therapeutic strategies. This review outlines the current state of AF prevention and treatment trials, including the foreseeable challenges, as discussed by a unique forum of clinical trialists, scientists, and regulatory representatives in a session endorsed by the Heart Rhythm Society at the 12th Global CardioVascular Clinical Trialists Forum in Washington, DC, December 3-5, 2015. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Characterization of individual straight and kinked boron carbide nanowires
NASA Astrophysics Data System (ADS)
Cui, Zhiguang
Boron carbides represent a class of ceramic materials with p-type semiconductor natures, complex structures and a wide homogeneous range of carbon compositions. Bulk boron carbides have long been projected as promising high temperature thermoelectric materials, but with limited performance. Bringing the bulk boron carbides to low dimensions (e.g., nanowires) is believed to be an option to enhance their thermoelectric performance because of the quantum size effects. However, the fundamental studies on the microstructure-thermal property relation of boron carbide nanowires are elusive. In this dissertation work, systematic structural characterization and thermal conductivity measurement of individual straight and kinked boron carbide nanowires were carried out to establish the true structure-thermal transport relation. In addition, a preliminary Raman spectroscopy study on identifying the defects in individual boron carbide nanowires was conducted. After the synthesis of single crystalline boron carbide nanowires, straight nanowires accompanied by the kinked ones were observed. Detailed structures of straight boron carbide nanowires have been reported, but not the kinked ones. After carefully examining tens of kinked nanowires utilizing Transmission Electron Microscopy (TEM), it was found that they could be categorized into five cases depending on the stacking faults orientations in the two arms of the kink: TF-TF, AF-TF, AF-AF, TF-IF and AF-IF kinks, in which TF, AF and IF denotes transverse faults (preferred growth direction perpendicular to the stacking fault planes), axial faults (preferred growth direction in parallel with the stacking fault planes) and inclined faults (preferred growth direction neither perpendicular to nor in parallel with the stacking fault planes). Simple structure models describing the characteristics of TF-TF, AF-TF, AF-AF kinked nanowires are constructed in SolidWorks, which help to differentiate the kinked nanowires viewed from the zone axes where stacking faults are invisible. In collaboration with the experts in the field of thermal property characterization of one dimensional nanostructures, thermal conductivities of over 60 nanowires including both straight and kinked ones have been measured in the temperature range of 20 - 420 K and the parameters (i.e., carbon contents, diameters, stacking faults densities/orientations and kinks) affecting the phonon transport were explored. The results disclose strong carbon content and diameter dependence of thermal conductivities of boron carbide nanowires, which decreases as lowering the carbon content and diameter. Stacking fault orientations do modulate the phonon transport (kappaTF < kappa AF), while stacking fault densities seems to only have obvious effects on phonon transport when meeting certain threshold ( 39%). The most interesting discovery is significant reduction of thermal conductivity (15% - 40%) in kinked boron carbide nanowires due to phonon mode conversions and scattering at the kink site. Last but not least, micro-Raman spectroscopy study on individual boron carbide nanowires has been performed for the first time, to the best of our knowledge. Based on the preliminary data, it is found that the stacking fault orientations have no apparent effect on the Raman scattering, but the stacking fault densities do. In addition, up as the size going down to nanoscale, some Raman modes are inactive while some new ones show up, which is largely ascribed to the quantum confinement effects. One more important finding is that the carbon content also plays important role in the Raman scattering of boron carbide nanowires in the low frequency region (< 600 cm-1), which mainly comes from the 3-atom chains (C-B-C or C-B-B).
Oldgren, Jonas; Healey, Jeff S; Ezekowitz, Michael; Commerford, Patrick; Avezum, Alvaro; Pais, Prem; Zhu, Jun; Jansky, Petr; Sigamani, Alben; Morillo, Carlos A; Liu, Lisheng; Damasceno, Albertino; Grinvalds, Alex; Nakamya, Juliet; Reilly, Paul A; Keltai, Katalin; Van Gelder, Isabelle C; Yusufali, Afzal Hussein; Watanabe, Eiichi; Wallentin, Lars; Connolly, Stuart J; Yusuf, Salim
2014-04-15
Atrial fibrillation (AF) is the most common sustained arrhythmia; however, little is known about patients in a primary care setting from high-, middle-, and low-income countries. This prospective registry enrolled patients presenting to an emergency department with AF at 164 sites in 46 countries representing all inhabited continents. Patient characteristics were compared among 9 major geographic regions. Between September 2008 and April 2011, 15,400 patients were enrolled. The average age was 65.9, standard deviation 14.8 years, ranging from 57.2, standard deviation 18.8 years in Africa, to 70.1, standard deviation 13.4 years in North America, P<0.001. Hypertension was globally the most common risk factor for AF, ranging in prevalence from 41.6% in India to 80.7% in Eastern Europe, P<0.001. Rheumatic heart disease was present in only 2.2% of North American patients, in comparison with 21.5% in Africa and 31.5% in India, P<0.001. The use of oral anticoagulation among patients with a CHADS2 score of ≥2 was greatest in North America (65.7%) but was only 11.2% in China, P<0.001. The mean time in the therapeutic range was 62.4% in Western Europe, 50.9% in North America, but only between 32% and 40% in India, China, Southeast Asia, and Africa, P<0.001. There is a large global variation in age, risk factors, concomitant diseases, and treatment of AF among regions. Improving outcomes globally requires an understanding of this variation and the conduct of research focused on AF associated with different underlying conditions and treatment of AF and predisposing conditions in different socioeconomic settings.
Quantitative fundus autofluorescence in healthy eyes.
Greenberg, Jonathan P; Duncker, Tobias; Woods, Russell L; Smith, R Theodore; Sparrow, Janet R; Delori, François C
2013-08-21
Fundus autofluorescence was quantified (qAF) in subjects with healthy retinae using a standardized approach. The objective was to establish normative data and identify factors that influence the accumulation of RPE lipofuscin and/or modulate the observed AF signal in fundus images. AF images were acquired from 277 healthy subjects (age range: 5-60 years) by employing a Spectralis confocal scanning laser ophthalmoscope (cSLO; 488-nm excitation; 30°) equipped with an internal fluorescent reference. For each image, mean gray level was calculated as the average of eight preset regions, and was calibrated to the reference, zero-laser light, magnification, and optical media density from normative data on lens transmission spectra. Relationships between qAF and age, sex, race/ethnicity, eye color, refraction/axial length, and smoking status were evaluated as was measurement repeatability and the qAF spatial distribution. qAF levels exhibited a significant increase with age. qAF increased with increasing eccentricity up to 10° to 15° from the fovea and was highest superotemporally. qAF values were significantly greater in females, and, compared with Hispanics, qAF was significantly higher in whites and lower in blacks and Asians. No associations with axial length and smoking were observed. For two operators, between-session repeatability was ± 9% and ± 12%. Agreement between the operators was ± 13%. Normative qAF data are a reference tool essential to the interpretation of qAF measurements in ocular disease.
Long-term follow-up of DDD pacing mode.
Ulman, Mateusz; Dębski, Maciej; Ząbek, Andrzej; Haberka, Kazimierz; Lelakowski, Jacek; Małecka, Barbara
2014-01-01
The aim of this study was to determine the long-term survival of DDD pacing and identify the main reasons for its loss. The study group consisted of 496 patients in whom a DDD pacing system was implanted between October 1984 and March 2002 and who were followed up until July 2010. The follow-up period was 152.1 ± 35.5 months. The patients' mean age at the time of implantation was 59.5 ± 12.5 years, and 53.5% were male; 58% had sick sinus syndrome (SSS), 26% had atrioventricular block (AVB), 15% had both of these indications simultaneously, and 1% had other indications. The incidence of lead malfunction, progression to chronic atrial fibrillation (AF), and the rate of infective complications was analysed. During the follow-up, 369 patients remained in DDD mode stimulation. DDD mode survival rate at one, five, ten and 15 years was, respectively, 96%, 86%, 77% and 72%. The most common reason for reprogramming out of DDD mode was the development of permanent AF in 65 (13.1%) patients. The occurrence of chronic AF was associated with a prior history of paroxysmal AF (p = 0.0001), SSS (p = 0.0215), and older age at time of implantation (p = 0.0068) compared to patients who remained in sinus rhythm. Lead malfunction caused loss of DDD mode pacing in 56 (11.3%) patients. Atrial leads were damaged in 37 patients, ventricular in 12 patients, and both leads in seven patients. The subclavian vein puncture was correlated with the mechanical damage of the atrial lead (p = 0.02935) compared to cephalic vein access. At the moment of complication, the patients with a dysfunctional lead were significantly younger than those who progressed to chronic AF(p = 0.0019). Infective complications which caused temporary loss of DDD pacing were observed in six patients: five had pocket infection and one had lead-dependent infective endocarditis. 1. Effective DDD pacing from the originally implanted system was noted in a high percentage (72%) of patients in long-term observation (15 years). 2. Progression to permanent AF is the most common reason for loss of DDD pacing;a history of paroxysmal AF and old age are the risk factors. 3. Subclavian vein puncture is associated with a higher rate of atrial lead damage.
Influence of atrial substrate on local capture induced by rapid pacing of atrial fibrillation.
Rusu, Alexandru; Jacquemet, Vincent; Vesin, Jean-Marc; Virag, Nathalie
2014-05-01
Preliminary studies showed that the septum area was the only location allowing local capture of both the atria during rapid pacing of atrial fibrillation (AF) from a single site. The present model-based study investigated the influence of atrial substrate on the ability to capture AF when pacing the septum. Three biophysical models of AF with an identical anatomy from human atria but with different AF substrates were used: (i) AF based on multiple wavelets, (ii) AF based on heterogeneities in vagal activation, (iii) AF based on heterogeneities in repolarization. A fourth anatomical model without Bachmann's bundle (BB) was also implemented. Rapid pacing was applied from the septum at pacing cycle lengths in the range of 50-100% of AF cycle length. Local capture was automatically assessed with 24 pairs of electrodes evenly distributed on the atrial surface. The results were averaged over 16 AF simulations. In the homogeneous substrate, AF capture could reach 80% of the atrial surface. Heterogeneities degraded the ability to capture during AF. In the vagal substrate, the capture tended to be more regular and the degradation of the capture was not directly related to the spatial extent of the heterogeneities. In the third substrate, heterogeneities induced wave anchorings and wavebreaks even in areas close to the pacing site, with a more dramatic effect on AF capture. Finally, BB did not significantly affect the ability to capture. Atrial fibrillation substrate had a significant effect on rapid pacing outcomes. The response to therapeutic pacing may therefore be specific to each patient.
Atrial Fibrillation and Colonic Neoplasia in African Americans.
Nouraie, Mehdi; Kansal, Vandana; Belfonte, Cassius; Ghazvini, Mohammad; Haidari, Tahmineh; Shahnazi, Anahita; Brim, Hassan; Soliman, Elsayed Z; Ashktorab, Hassan
2015-01-01
Colorectal cancer (CRC) and atrial fibrillation/flutter (AF) share several risk factors including increasing age and obesity. However, the association between CRC and AF has not been thoroughly examined, especially in African Americans. In this study we aimed to assess the prevalence of AF and its risk factors in colorectal neoplasia in an African American. We reviewed records of 527 African American patients diagnosed with CRC and 1008 patients diagnosed with benign colonic lesions at Howard University Hospital from January 2000 to December 2012. A control group of 731 hospitalized patients without any cancer or colonic lesion were randomly selected from the same time and age range, excluding patients who had diagnosis of both CRC and/or adenoma. The presence or absence of AF was based upon ICD-9 code documentation. The prevalence of AF in these three groups was compared by multivariate logistic regression. The prevalence of AF was highest among CRC patients (10%) followed by adenoma patients (7.2%) then the control group (5.4%, P for trend = 0.002). In the three groups of participants, older age (P<0.008) and heart failure (P<0.001) were significantly associated with higher risk of AF. After adjusting for these risk factors, CRC (OR: 1.4(95%CI):0.9-2.2, P = 0.2) and adenoma (OR: 1.1(95%CI):0.7-1.6, P = 0.7) were not significantly associated AF compared to control group. AF is highly prevalent among CRC patients; 1 in 10 patients had AF in our study. The predictors of AF in CRC was similar to that in adenoma and other patients after adjustment for potential confounders suggesting that the increased AF risk in CRC is explained by higher prevalence of AF risk factors.
Linking main-belt comets to asteroid families
NASA Astrophysics Data System (ADS)
Novakovic, B.; Hsieh, H. H.; Cellino, A.
2012-09-01
Here we present our results obtained by applying different methods in order to establish a firm link between the main-belt comets (MBCs) and colisionally-formed asteroid families (AFs), i.e, to possibly find additional line of evidence supporting the hypothesis that MBCs may be preferentially found among the members of young AFs.
Davis, J. C. Séamus; Lee, Dung-Hai
2013-01-01
Unconventional superconductivity (SC) is said to occur when Cooper pair formation is dominated by repulsive electron–electron interactions, so that the symmetry of the pair wave function is other than an isotropic s-wave. The strong, on-site, repulsive electron–electron interactions that are the proximate cause of such SC are more typically drivers of commensurate magnetism. Indeed, it is the suppression of commensurate antiferromagnetism (AF) that usually allows this type of unconventional superconductivity to emerge. Importantly, however, intervening between these AF and SC phases, intertwined electronic ordered phases (IP) of an unexpected nature are frequently discovered. For this reason, it has been extremely difficult to distinguish the microscopic essence of the correlated superconductivity from the often spectacular phenomenology of the IPs. Here we introduce a model conceptual framework within which to understand the relationship between AF electron–electron interactions, IPs, and correlated SC. We demonstrate its effectiveness in simultaneously explaining the consequences of AF interactions for the copper-based, iron-based, and heavy-fermion superconductors, as well as for their quite distinct IPs. PMID:24114268
Takeda, A; Suzuki, M; Tempaku, M; Ohashi, K; Tamano, H
2015-09-24
Physiological significance of synaptic Zn(2+) signaling was examined in the CA1 of young rats. In vivo CA1 long-term potentiation (LTP) was induced using a recording electrode attached to a microdialysis probe and the recording region was locally perfused with artificial cerebrospinal fluid (ACSF) via the microdialysis probe. In vivo CA1 LTP was inhibited under perfusion with CaEDTA and ZnAF-2DA, extracellular and intracellular Zn(2+) chelators, respectively, suggesting that the influx of extracellular Zn(2+) is required for in vivo CA1 LTP induction. The increase in intracellular Zn(2+) was chelated with intracellular ZnAF-2 in the CA1 1h after local injection of ZnAF-2DA into the CA1, suggesting that intracellular Zn(2+) signaling induced during learning is blocked with intracellular ZnAF-2 when the learning was performed 1h after ZnAF-2DA injection. Object recognition was affected when training of object recognition test was performed 1h after ZnAF-2DA injection. These data suggest that intracellular Zn(2+) signaling in the CA1 is required for object recognition memory via LTP. Surprisingly, in vivo CA1 LTP was affected under perfusion with 0.1-1μM ZnCl2, unlike the previous data that in vitro CA1 LTP was enhanced in the presence of 1-5μM ZnCl2. The influx of extracellular Zn(2+) into CA1 pyramidal cells has bidirectional action in CA1 LTP. The present study indicates that the degree of extracellular Zn(2+) influx into CA1 neurons is critical for LTP and cognitive performance. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.
[Chronic outcome of patients with paroxysmal atrial fibrillation post catheter ablation].
Lin, Yu-bi; Xia, Yun-long; Gao, Lian-jun; Chu, Zhen-liang; Cong, Pei-xin; Chang, Dong; Yin, Xiao-meng; Zhang, Shu-long; Yang, Dong-Hui; Yang, Yan-Zong
2009-12-01
High short-term successful rate was reported for catheter ablation in patients with paroxysmal atrial fibrillation (AF), we analyzed the long-term outcome (success rate, anticoagulation therapy and embolism event, anti-arrhythmic therapy and death post procedure) of catheter ablation for paroxysmal AF in this study. From January 2000 to December 2004, 106 consecutive patients with drug-refractory paroxysmal AF underwent catheter ablation and were followed-up for (60.7 + or - 11.8) months. Segmental pulmonary vein isolation (SPVI) was routinely performed by radiofrequency energy under the guidance of circular mapping catheter. The patients were followed up with 24 h-holter, ECG, telephone or letter. Data on recurrence of AF, the anticoagulation medication and the incidence of embolism, anti-arrhythmic therapy were obtained. There were 9 patients lost to follow up. In the remaining 97 patients [65 males, (54.8 + or - 11.2) years old], 3 cases died from cancer, sinus rhythm was maintained in 68 patients (Group S, 72.3%) and AF recurrence evidenced in 26 patients (Group R, 27.7%). In Group S, 56 patients (82.4%) discontinued anticoagulation medication, and 12 patients continued to take aspirin. There was no embolism event in Group S during follow-up. In Group R, 1 patient continued to take warfarin; 11 patients continued to take aspirin and 2 patients suffered from cerebral embolism. Anticoagulation medication was discontinued in 14 patients (53.8%) and 1 patient suffered form cerebral embolism. The incidence of embolism event in Group R is significantly higher than in Group S (P < 0.01). More patients discontinued anti-arrhythmic medication in Group S than in Group R (80.9% vs. 56.0%, P < 0.05). Catheter ablation is associated with satisfactory long-term success rate, reduced anti-arrhythmia medication, improved quality of life in patients with paroxysmal AF.
Magnetic Ordering under Strain and Spin-Peierls Dimerization in GeCuO3
NASA Astrophysics Data System (ADS)
Filippetti, Alessio; Fiorentini, Vincenzo
2007-05-01
Studying from first principles the competition between ferromagnetic (FM) and antiferromagnetic (AF) interactions in the charge-transfer-insulator GeCuO3, we predict that a small external pressure should switch the uniform AF ground state to FM, and estimate (using exchange parameters computed as a function of strain) the competing AF couplings and the transition temperature to the dimerized spin-Peierls state. Although idealized as a one-dimensional Heisenberg antiferromagnet, GeCuO3 is found to be influenced by nonideal geometry and side groups.
Action of AF64A on rat brain muscarinic receptors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eva, C.; Costa, E.
ICV administration of compound AF64A (ethylcholine mustard aziridium ion) induces a long-term selective cholinergic hypofunction; however, it does not modify the characteristics of muscarinic receptors. In brain muscarinic receptor activation can either stimulate phosphoinositide turnover or inhibit adenylate cyclase. ICV infusion of AF64A (5 nmol/side/2.5 ..mu..l) reduced the hippocampal ACh content 10 or 30 days after the treatment to 75% of the control values. Under these conditions neither in the striatum nor in the frontal cortex ACh levels were decreased. The carbachol dose-dependent stimulation in hippocampal slices differed from that observed in control rats. The carbachol efficacy was increased butmore » its potency was unchanged by AF64A. In contrast, ICV administration of AF64A failed to alter the oxotremorine efficacy or potency in inhibiting the forskolin stimulated adenylate cyclase in rat hippocampal membranes. These results suggest the two transducer systems coupled to muscarinic receptors may be differentially regulatable by cholinergic input.« less
CIACCIO, EDWARD J.; BIVIANO, ANGELO B.; GAMBHIR, ALOK; EINSTEIN, ANDREW J.; GARAN, HASAN
2014-01-01
Background When atrial fibrillation (AF) is incessant, imaging during a prolonged ventricular RR interval may improve image quality. It was hypothesized that long RR intervals could be predicted from preceding RR values. Methods From the PhysioNet database, electrocardiogram RR intervals were obtained from 74 persistent AF patients. An RR interval lengthened by at least 250 ms beyond the immediately preceding RR interval (termed T0 and T1, respectively) was considered prolonged. A two-parameter scatterplot was used to predict the occurrence of a prolonged interval T0. The scatterplot parameters were: (1) RR variability (RRv) estimated as the average second derivative from 10 previous pairs of RR differences, T13–T2, and (2) Tm–T1, the difference between Tm, the mean from T13 to T2, and T1. For each patient, scatterplots were constructed using preliminary data from the first hour. The ranges of parameters 1 and 2 were adjusted to maximize the proportion of prolonged RR intervals within range. These constraints were used for prediction of prolonged RR in test data collected during the second hour. Results The mean prolonged event was 1.0 seconds in duration. Actual prolonged events were identified with a mean positive predictive value (PPV) of 80% in the test set. PPV was >80% in 36 of 74 patients. An average of 10.8 prolonged RR intervals per 60 minutes was correctly identified. Conclusions A method was developed to predict prolonged RR intervals using two parameters and prior statistical sampling for each patient. This or similar methodology may help improve cardiac imaging in many longstanding persistent AF patients. PMID:23998759
Imaging Mass Spectrometry for Characterization of Atrial Fibrillation Subtypes.
Klein, Oliver; Hanke, Thorsten; Nerbrich, Grit; Yan, Junfeng; Schubert, Benedikt; Giavalisco, Patrick; Noack, Frank; Thiele, Herbert; Mohamed, Salah A
2018-05-13
Atrial fibrillation (AF) is a cardiac arrhythmia characterized by a rapid and irregular heart rhythm. AF types, paroxysmal (PX), persistent (PE) and long-lasting persistent (LSP), requires differences in clinical management. Unfortunately, a significant proportion of AF patients are clinical misclassified. Therefore, our study aim that MALDI-Imaging (IMS) is valuable as a diagnostic aid in AF subtypes assessment. Patients were clinically classified according guidelines of the European Society of Cardiology. FFPE tissue specimens from PE, PX and LSP subtype were analysed by MALDI-IMS and evaluated by multi-statistical testing. Proteins were subsequent identified using LC-MS/MS and findings were confirmed by immunohistochemistry and through the determination of potential fibrosis via histopathology RESULT: : Determined characteristic peptide signatures and peptide values facilitate to distinguish between PE, PE and LSP arterial fibrillation subtypes. In particular, peptide values from alpha 1 type I collagen were identified that were significantly higher in LSP and PE tissue but not in PX myocardial AF tissue. These findings were confirmed by immunohistochemistry and through the determination of potential fibrosis via histopathology. Our results represent an improvement in AF risk stratification by using MALDI-IMS as a promising approach for AF tissue assessment. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
NASA Astrophysics Data System (ADS)
Song, Yu-Ling; Ta, Jin-Xing; Wang, Xuan-Zhang
2012-03-01
Second harmonic generation (SHG) from a short-period structure composed of alternating antiferromagnetic (AF) and ionic-crystal layers is investigated, where the generated harmonic waves are situated in the far-infrared range and attributed to the magnetically nonlinear interaction in AF layers. The presence of a kind of appropriate ionic-crystal layers in the structure can support negative refraction for the pumping wave and positive refraction for the SH wave, so the SHG is greatly amplified in the vicinity of each AF resonant frequency. For the composite structure FeF2/TlBr, we found that the SH output is about 8 times higher than that of the FeF2 bulk in the same frequency range.
Entanglement entropy for the long-range Ising chain in a transverse field.
Koffel, Thomas; Lewenstein, M; Tagliacozzo, Luca
2012-12-28
We consider the Ising model in a transverse field with long-range antiferromagnetic interactions that decay as a power law with their distance. We study both the phase diagram and the entanglement properties as a function of the exponent of the interaction. The phase diagram can be used as a guide for future experiments with trapped ions. We find two gapped phases, one dominated by the transverse field, exhibiting quasi-long-range order, and one dominated by the long-range interaction, with long-range Néel ordered ground states. We determine the location of the quantum critical points separating those two phases. We determine their critical exponents and central charges. In the phase with quasi-long-range order the ground states exhibit exotic corrections to the area law for the entanglement entropy coexisting with gapped entanglement spectra.
Management of atrial fibrillation in Greece: the MANAGE-AF study.
Andrikopoulos, George; Pastromas, Sokratis; Mantas, Ioannis; Sakellariou, Dimitris; Kyrpizidis, Christos; Makridis, Pantelis; Goumas, Georgios; Stakos, Dimitris; Gotsis, Alexandros; Kartalis, Athanasios; Kazianis, Georgios; Babalis, Dimitrios; Toli, Konstantina; Tzeis, Stylianos; Papavasileiou, Maria; Kalogeropoulos, Petros; Vardas, Panos
2014-01-01
Although atrial fibrillation (AF) is a highly prevalent health problem with high morbidity and mortality, data regarding the clinical characteristics and management of AF in the Greek population are scarce. The "Current Clinical Practice in the MANAGEment of Atrial Fibrillation in Greece" study (MANAGEAF) aimed to assess the epidemiological features as well as the daily clinical practice in the management of Greek patients with AF. Taking into consideration the distribution of the Greek population, 603 consecutive patients over 18 years of age, with any type of AF, presenting at the emergency departments or outpatient clinics of 27 different centers, were included in our study. The mean age of the patients was 68.5 ± 12.1 years, with male patients representing 52.5% of the study population. The most common AF type in our cohort was non-paroxysmal AF (60%), including the patients with permanent (24.1%), persistent (17.4%), long-standing (4.8%) and first diagnosed AF (13.8%). Hypertension was the most common comorbidity (70.3%). A history of stroke or transient ischemic attack was detected in 9.2% of the patients, while 6.2% had a history of gastrointestinal bleeding. About half of the patients (49.3%) were treated with anticoagulant drugs, mainly vitamin K antagonists (46.9%), while 34.2% were on antiplatelet drugs, aspirin and/or clopidogrel. The mean INR level (1.7 ± 0.8) was sub-therapeutic, although the mean values for CHADS2 and CHA2DS2-VASc scores were 1.6 ± 1.2 and 3.0 ± 1.7, respectively. The MANAGE-AF baseline results indicate unsatisfactory levels of compliance with the current guidelines for the management of AF in Greece. Considering the undisputed effectiveness of anticoagulant treatment for preventing AF-related strokes, MANAGE-AF demonstrates the need for optimization of our therapeutic strategies for the management of cardioembolic stroke risk.
Atrial fibrillation and stroke: the evolving role of rhythm control.
Patel, Taral K; Passman, Rod S
2013-06-01
Atrial fibrillation (AF) remains a major risk factor for stroke. Unfortunately, clinical trials have failed to demonstrate that a strategy of rhythm control--therapy to maintain normal sinus rhythm (NSR)--reduces stroke risk. The apparent lack of benefit of rhythm control likely reflects the difficulty in maintaining NSR using currently available therapies. However, there are signals from several trials that the presence of NSR is indeed beneficial and associated with better outcomes related to stroke and mortality. Most electrophysiologists feel that as rhythm control strategies continue to improve, the crucial link between rhythm control and stroke reduction will finally be demonstrated. Therefore, AF specialists tend to be aggressive in their attempts to maintain NSR, especially in patients who have symptomatic AF. A step-wise approach from antiarrhythmic drugs to catheter ablation to cardiac surgery is generally used. In select patients, catheter ablation or cardiac surgery may supersede antiarrhythmic drugs. The choice depends on the type of AF, concurrent heart disease, drug toxicity profiles, procedural risks, and patient preferences. Regardless of strategy, given the limited effectiveness of currently available rhythm control therapies, oral anticoagulation is still recommended for stroke prophylaxis in AF patients with other stroke risk factors. Major challenges in atrial fibrillation management include selecting patients most likely to benefit from rhythm control, choosing specific antiarrhythmic drugs or procedures to achieve rhythm control, long-term monitoring to gauge the efficacy of rhythm control, and determining which (if any) patients may safely discontinue anticoagulation if long-term NSR is achieved.
Kapur, Sunil; Kumar, Saurabh; John, Roy M; Stevenson, William G; Tedrow, Usha B; Koplan, Bruce A; Epstein, Laurence M; MacRae, Calum A; Michaud, Gregory F
2018-06-01
A commonly held notion is that patients with a family history of atrial fibrillation (AF) have worse atrial substrate and higher rates of arrhythmia recurrence following ablation. We sought to examine differences in atrial substrate and catheter ablation outcomes in patients with a 1st degree family member with paroxysmal or persistent AF (PeAF) compared to those without. A total of 256 consecutive patients undergoing their 1st ablation for AF (123 paroxysmal, 133 persistent) with >1 year follow up were included. The presence of one 1st-degree family relative was defined as a 'positive family history'. Clinical characteristics, electroanatomic map findings, ablation characteristics and outcomes were compared in patients with and without a positive family history of AF. Patients with paroxysmal fibrillation with a positive family history (n = 57; 46%) had similar clinical characteristics and arrhythmia recurrence after catheter ablation as those without. Of those that recurred, patients with a positive family history were more likely to have progressed to PeAF (P = 0.05). Patients with PeAF with a positive family history (n = 75; 56%) had similar clinical characteristics, electroanatomic mapping findings and ablation characteristics, but worse long term arrhythmia free survival (P = 0.04). The presence of a 1st-degree family member with AF does not impact the clinical outcomes of catheter ablation for paroxysmal AF. However, a positive family history is associated with worse arrhythmia free survival in patients with PeAF. This finding is not explained by differences in clinical characteristics, atrial substrate assessed by voltage maps or ablation characteristics.
Diederichsen, Søren Zöga; Haugan, Ketil Jørgen; Køber, Lars; Højberg, Søren; Brandes, Axel; Kronborg, Christian; Graff, Claus; Holst, Anders Gaarsdal; Nielsen, Jonas Bille; Krieger, Derk; Svendsen, Jesper Hastrup
2017-05-01
Atrial fibrillation (AF) increases the rate of stroke 5-fold, and AF-related strokes have a poorer prognosis compared with non-AF-related strokes. Atrial fibrillation and stroke constitute an intensifying challenge, and health care organizations are calling for awareness on the topic. Previous studies have demonstrated that AF is often asymptomatic and consequently undiagnosed. The implantable loop recorder (ILR) allows for continuous, long-term electrocardiographic monitoring with daily transmission of arrhythmia information, potentially leading to improvement in AF detection and stroke prevention. The LOOP study is an investigator-initiated, randomized controlled trial with 6,000 participants randomized 3:1 to a control group or to receive an ILR with continuous electrocardiographic monitoring. Participants are identified from Danish registries and are eligible for inclusion if 70years or older and previously diagnosed as having at least one of the following conditions: hypertension, diabetes mellitus, heart failure, or previous stroke. Exclusion criteria include history of AF and current oral anticoagulation treatment. When an AF episode lasting ≥6minutes is detected, oral anticoagulation will be initiated according to guidelines. Expected follow-up is 4years. The primary end point is time to stroke or systemic embolism, whereas secondary end points include time to AF diagnosis and death. The LOOP study will evaluate health benefits and cost-effectiveness of ILR as a screening tool for AF to prevent stroke in patients at risk. Secondary objectives include identification of risk factors for the development of AF and characterization of arrhythmias in the population. The trial holds the potential to influence the future of stroke prevention. Copyright © 2017 Elsevier Inc. All rights reserved.
The orbital period of the dwarf nova AF Camelopardalis
NASA Astrophysics Data System (ADS)
Szkody, Paula; Howell, Steve B.
1989-04-01
Time-resolved optical spectroscopy of the dwarf nova AF Cam for 4.5 hr during a decline from outburst reveals that the orbital period is relatively long (5-6 hr). CCD photometry at quiescence also supports this finding. This rules out the previously observed 67-76 min modulations (evident in IR photometric measurements at quiescence and optical photometry at outburst) as orbital in nature.
Golive, Anjani; May, Heidi T; Bair, Tami L; Jacobs, Victoria; Crandall, Brian G; Cutler, Michael J; Day, John D; Mallender, Charles; Osborn, Jeffrey S; Stevens, Scott M; Weiss, J Peter; Woller, Scott C; Bunch, T Jared
2017-07-01
Among patients with atrial fibrillation (AF), the risk of stroke risk is a significant concern. CHADS 2 and CHA 2 DS 2 -VASc ≤2 scoring have been used to stratify patients into categories of risk. Without randomized, prospective data, the need and type of long-term antithrombotic medications for thromboembolism prevention in lower risk AF patients remains controversial. We sought to define the long-term impact of anticoagulant and antiplatelet therapy use in AF patients at low risk of stroke. A total of 56,764 patients diagnosed with AF and a CHADS 2 score of 0 or 1, or CHA 2 DS 2 -VASc score of 0, 1, or 2 were studied. Antithrombotic therapy was defined as aspirin, clopidogrel (antiplatelet therapy), or warfarin monotherapy (anticoagulation) initiated within 6 months of AF diagnosis. End points included all-cause mortality, cerebrovascular accident, transient ischemic attack (TIA), and major bleed. The average age of the population was 67.0 ± 14.1 years and 56.6% were male. In total, 9,682 received aspirin, 1,802 received clopidogrel, 1,164 received warfarin, and 46,042 did not receive any antithrombotic therapy. Event rates differed between patients with a CHADS 2 score of 0 and 1; 18.5% and 37.8% had died, 1.7% and 3.4% had a stroke, 2.2% and 3.2% had a TIA, and 14% and 12.5% had a major bleed, respectively (p <0.0001 for all). The rates of stroke, TIA, and major bleeding increased as antithrombotic therapy intensity increased from no therapy, to aspirin, to clopidogrel, and to warfarin (all p <0.0001). Similar outcomes were observed in low-risk CHA 2 DS 2 -VASc scores (0 to 2). In low-risk AF patients with a CHADS 2 score of 0 to 1 or CHA 2 DS 2 -VASc score of 0 to 2, the use of aspirin, clopidogrel, and warfarin was not associated with lower stroke rates at 5 years compared with no therapy. However, the use of antithrombotic agents was associated with a significant risk of bleed. Copyright © 2017 Elsevier Inc. All rights reserved.
A method for aircraft afterburner combustion without flameholders
NASA Astrophysics Data System (ADS)
Birmaher, Shai
2009-12-01
State of the art aircraft afterburners employ spray bars to inject fuel and flameholders to stabilize the combustion process. Such afterburner designs significantly increase the length (and thus weight), pressure losses, and observability of the engine. This thesis presents a feasibility study of a compact 'prime and trigger' (PAT) afterburner concept that eliminates the fuel spray bars and flameholders and, thus, eliminates the above-mentioned problems. In this concept, afterburner fuel is injected just upstream or in between the turbine stages. As the fuel travels through the turbine stages, it evaporates, mixes with the bulk flow, and undergoes some chemical reactions without any significant heat release, a process referred to as 'priming'. Downstream of the turbine stages, combustion could take place through autoignition. However, if fuel autoignition does not occur or if autoignition does not produce a combustion zone that is stable and highly efficient, then a low power pilot, or 'trigger', can be used to control the combustion process. The envisioned trigger for the PAT concept is a jet of product gas from ultra-rich hydrocarbon/air combustion that is injected through the afterburner liner. This 'partial oxidation' (POx) gas, which consists mostly of H2, CO, and diluents, rapidly produces radicals and heat that accelerate the autoignition of the primed mixture and, thus, provide an anchor point for the afterburner combustion process. The objective of this research was to demonstrate the feasibility of the PAT concept by showing that (1) combustion of fuel injected within or upstream of turbine stages can occur only downstream of the turbine stages, and (2) the combustion zone is compact, stable and efficient. This was accomplished using two experimental facilities, a developed theoretical model, and Chemkin simulations. The first facility, termed the Afterburner Facility (AF), simulated the bulk flow temperature, velocity and O2 content through a turbojet combustor, turbine stage and afterburner. To model the PAT concept, Jet-A was injected upstream of the simulated turbine stage and a H2 jet was used to trigger the primed Jet-A combustion process downstream of the turbine stage. H2 was used because POx gas was not available for experiments. The second facility, termed the Propane Autoignition Combustor (PAC), was essentially a scaled-down, simplified version of the AF. The PAC experiments focused on the trigger stage of the PAT concept, using H 2 in lieu of POx gas and employing measurement techniques that were in some ways more detailed than in the AF experiments. The developed model simulated the physics of fuel priming in the AF and predicted the Jet-A autoignition location. It was used to predict and interpret the AF results and to study the feasibility of the PAT concept at pressures outside the AF operating range. Finally, the Chemkin simulations were used to examine the effect of several POx gas compositions on the Jet-A/vitiated-air autoignition process; to compare the POx and H2 triggers; and to explore several reasons for why POx gas and H2 are suitable trigger mechanisms. he experimental, theoretical, and numerical results obtained in this investigation indicated that the PAT concept provides a feasible approach to afterburner combustion. The experiments in the AF showed that the ignition delay of Jet-A is sufficiently long to allow fuel injection within turbine stages without significant heat release upstream of the afterburner. In the AF experiments without the H2 trigger, Jet-A combustion was achieved through autoignition; however, the autoignition combustion zone exhibited large axial fluctuations and low combustion efficiency. The H2 trigger was able to shift the combustion zone upstream, make it more compact, reduce fluctuations in its axial position, and raise the combustion efficiency to nearly 100%. The PAC experiments also showed that a H2 trigger can shift the combustion zone upstream, make it more compact, and increase the combustion efficiency. The PAC results were obtained with lower O 2 content and higher equivalence ratios than in the AF. Therefore, the combined AF and PAC results suggested that the PAT concept is feasible over a wide range of operating conditions. The developed model showed good agreement with the AF results. It also predicted that the PAT concept is feasible at bulk flow pressures outside the AF operating range. Finally, the Chemkin results showed that both the H2 and POx gas triggers can significantly reduce the ignition delay time of primed Jet-A/vitiated air mixtures. Thus, POx gas is a suitable trigger for the PAT concept and should be tested in future experimental investigations.
Amniotic fluid: Source of trophic factors for the developing intestine
Dasgupta, Soham; Arya, Shreyas; Choudhary, Sanjeev; Jain, Sunil K
2016-01-01
The gastrointestinal tract (GIT) is a complex system, which changes in response to requirements of the body. GIT represents a barrier to the external environment. To achieve this, epithelial cells must renew rapidly. This renewal of epithelial cells starts in the fetal life under the influence of many GIT peptides by swallowing amniotic fluid (AF). Development and maturation of GIT is a very complex cascade that begins long before birth and continues during infancy and childhood by breast-feeding. Many factors like genetic preprogramming, local and systemic endocrine secretions and many trophic factors (TF) from swallowed AF contribute and modulate the development and growth of the GIT. GIT morphogenesis, differentiation and functional development depend on the activity of various TF in the AF. This manuscript will review the role of AF borne TF in the development of GIT. PMID:26909227
Audit and feedback interventions to improve endoscopist performance: Principles and effectiveness.
Tinmouth, Jill; Patel, Jigisha; Hilsden, Robert J; Ivers, Noah; Llovet, Diego
2016-06-01
There is considerable variation in the quality of colonoscopy, attributable in part to endoscopist performance. Audit and feedback (A&F) provides health professionals with a summary of their performance over a period of time and is a common strategy used to improve provider performance. In this review, we discuss current understanding of the mechanism of A&F and describe specific features of effective A&F. To date, trials of A&F to improve colonoscopy performance report heterogeneous results, in part because colonoscopy is a complex procedural skill but also because the quality improvement interventions were sub-optimally implemented or inadequately evaluated. Nonetheless, evidence from a wide range of literature suggests that A&F has the potential to improve endoscopist performance. We discuss future directions for research in this area and provide guidance for providers or health system planners wishing to implement A&F to address quality of colonoscopy in their practice and/or jurisdiction. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ameloblastic fibrosarcoma of the upper jaw: Report of a rare case with long-term follow-up
Khalili, Maryam; Shakib, Pouyan Amini
2013-01-01
Ameloblastic fibrosarcoma (AFS) is a rare malignant mixed odontogenic tumor which is usually considered as the malignant counterpart of ameloblastic fibroma. Only mesenchymal component represents sarcomatous alterations and ameloblast-like epithelial nest remains bland in AFS. Here, we report a case of AFS in a 26-year-old man in the maxilla, which was regarded as an uncommon location for this tumor. After 2 years follow up, no evidence of recurrence was noted. We also emphasize on comprehensive clinical, radiographic, and histopathologic evaluation of such patients rather than immunohistochemical staining to make an accurate diagnosis. PMID:23878574
Biomaterials in the treatment of anal fistula: hope or hype?
Scoglio, Daniele; Walker, Avery S; Fichera, Alessandro
2014-12-01
Anal fistula (AF) presents a chronic problem for patients and colorectal surgeons alike. Surgical treatment may result in impairment of continence and long-term risk of recurrence. Treatment options for AFs vary according to their location and complexity. The ideal approach should result in low recurrence rates and minimal impact on continence. New technical approaches involving biologically derived products such as biological mesh, fibrin glue, fistula plug, and stem cells have been applied in the treatment of AF to improve outcomes and decrease recurrence rates and the risk of fecal incontinence. In this review, we will highlight the current evidence and describe our personal experience with these novel approaches.
Leftheriotis, Dionyssios; Flevari, Panayota; Kossyvakis, Charalampos; Katsaras, Dimitrios; Batistaki, Chrysanthi; Arvaniti, Chrysa; Giannopoulos, Georgios; Deftereos, Spyridon; Kostopanagiotou, Georgia; Lekakis, John
2016-11-01
In experimental models, stellate ganglion block (SGB) reduces the induction of atrial fibrillation (AF), while data in humans are limited. The aim of this study was to assess the effect of unilateral SGB on atrial electrophysiological properties and AF induction in patients with paroxysmal AF. Thirty-six patients with paroxysmal AF were randomized in a 2:1 order to temporary, transcutaneous, pharmaceutical SGB with lidocaine or placebo before pulmonary vein isolation. Lidocaine was 1:1 randomly infused to the right or left ganglion. Before and after randomization, atrial effective refractory period (ERP) of each atrium, difference between right and left atrial ERP, intra- and interatrial conduction time, AF inducibility, and AF duration were assessed. After SGB, right atrial ERP was prolonged from a median (1st-3rd quartile) of 240 (220-268) ms to 260 (240-300) ms (P < .01) and left atrial ERP from 235 (220-260) ms to 245 (240-280) ms (P < .01). AF was induced by atrial pacing in all 24 patients before SGB, but only in 13 patients (54%) after the intervention (P < .01). AF duration was shorter after SGB: 1.5 (0.0-5.8) minutes from 5.5 (3.0-12.0) minutes (P < .01). Intra- and interatrial conduction time was not significantly prolonged. No significant differences were observed between right and left SGB. No changes were observed in the placebo group. Unilateral temporary SGB prolonged atrial ERP, reduced AF inducibility, and decreased AF duration. An equivalent effect of right and left SGB on both atria was observed. These findings may have a clinical implication in the prevention of drug refractory and postsurgery AF and deserve further clinical investigation. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Burkowitz, Jörg; Merzenich, Carina; Grassme, Kathrin; Brüggenjürgen, Bernd
2016-08-01
Insertable or implantable cardiac monitors (ICMs) continuously monitor the heart rhythm and record irregularities over 3 years, enabling the diagnosis of infrequent rhythm abnormalities associated with syncope and stroke. The enhanced recognition capabilities of recent ICM models are able to accurately detect atrial fibrillation (AF) and have led to new applications of ICMs for the detection and monitoring of AF. Based on a systematic literature search, two indications were identified for ICMs for which considerable evidence, including randomized studies, exists: diagnosing the underlying cardiac cause of unexplained recurrent syncope and detecting AF in patients after cryptogenic stroke (CS). Three randomized controlled trials (RCTs) were identified that compared the effectiveness of ICMs in diagnosing patients with unexplained syncope (n = 556) to standard of care. A meta-analysis was conducted in order to generate an overall effect size and confidence interval of the diagnostic yield of ICMs versus conventional monitoring. In the indication CS, one RCT and five observational studies were included in order to assess the performance of ICMs in diagnosing patients with AF (n = 1129). Based on these studies, there is strong evidence that ICMs provide a higher diagnostic yield for detecting arrhythmias in patients with unexplained syncope and for detection of AF in patients after CS compared to conventional monitoring. Prolonged monitoring with ICMs is an effective tool for diagnosing the underlying cardiac cause of unexplained syncope and for detecting AF in patients with CS. In all RCTs, ICMs have a superior diagnostic yield compared to conventional monitoring. © The European Society of Cardiology 2016.
NASA Astrophysics Data System (ADS)
Fenech, Sara; Doherty, Ruth M.; Heaviside, Clare; Vardoulakis, Sotiris; Macintyre, Helen L.; O'Connor, Fiona M.
2018-04-01
We examine the impact of model horizontal resolution on simulated concentrations of surface ozone (O3) and particulate matter less than 2.5 µm in diameter (PM2.5), and the associated health impacts over Europe, using the HadGEM3-UKCA chemistry-climate model to simulate pollutant concentrations at a coarse (˜ 140 km) and a finer (˜ 50 km) resolution. The attributable fraction (AF) of total mortality due to long-term exposure to warm season daily maximum 8 h running mean (MDA8) O3 and annual-average PM2.5 concentrations is then calculated for each European country using pollutant concentrations simulated at each resolution. Our results highlight a seasonal variation in simulated O3 and PM2.5 differences between the two model resolutions in Europe. Compared to the finer resolution results, simulated European O3 concentrations at the coarse resolution are higher on average in winter and spring (˜ 10 and ˜ 6 %, respectively). In contrast, simulated O3 concentrations at the coarse resolution are lower in summer and autumn (˜ -1 and ˜ -4 %, respectively). These differences may be partly explained by differences in nitrogen dioxide (NO2) concentrations simulated at the two resolutions. Compared to O3, we find the opposite seasonality in simulated PM2.5 differences between the two resolutions. In winter and spring, simulated PM2.5 concentrations are lower at the coarse compared to the finer resolution (˜ -8 and ˜ -6 %, respectively) but higher in summer and autumn (˜ 29 and ˜ 8 %, respectively). Simulated PM2.5 values are also mostly related to differences in convective rainfall between the two resolutions for all seasons. These differences between the two resolutions exhibit clear spatial patterns for both pollutants that vary by season, and exert a strong influence on country to country variations in estimated AF for the two resolutions. Warm season MDA8 O3 levels are higher in most of southern Europe, but lower in areas of northern and eastern Europe when simulated at the coarse resolution compared to the finer resolution. Annual-average PM2.5 concentrations are higher across most of northern and eastern Europe but lower over parts of southwest Europe at the coarse compared to the finer resolution. Across Europe, differences in the AF associated with long-term exposure to population-weighted MDA8 O3 range between -0.9 and +2.6 % (largest positive differences in southern Europe), while differences in the AF associated with long-term exposure to population-weighted annual mean PM2.5 range from -4.7 to +2.8 % (largest positive differences in eastern Europe) of the total mortality. Therefore this study, with its unique focus on Europe, demonstrates that health impact assessments calculated using modelled pollutant concentrations, are sensitive to a change in model resolution by up to ˜ ±5 % of the total mortality across Europe.
Paroxysmal atrial fibrillation recognition based on multi-scale Rényi entropy of ECG.
Xin, Yi; Zhao, Yizhang; Mu, Yuanhui; Li, Qin; Shi, Caicheng
2017-07-20
Atrial fibrillation (AF) is a common type of arrhythmia disease, which has a high morbidity and can lead to some serious complications. The ability to detect and in turn prevent AF is extremely significant to the patient and clinician. Using ECG to detect AF and develop a robust and effective algorithm is the primary objective of this study. Some studies show that after AF occurs, the regulatory mechanism of vagus nerve and sympathetic nerve will change. Each R-R interval will be absolutely unequal. After studying the physiological mechanism of AF, we will calculate the Rényi entropy of the wavelet coefficients of heart rate variability (HRV) in order to measure the complexity of PAF signals, as well as extract the multi-scale features of paroxysmal atrial fibrillation (PAF). The data used in this study is obtained from MIT-BIH PAF Prediction Challenge Database and the correct rate in classifying PAF patients from normal persons is 92.48%. The results of this experiment proved that AF could be detected by using this method and, in turn, provide opinions for clinical diagnosis.
Ogino, Yutaka; Ishikawa, Toshiyuki; Ishigami, Tomoaki; Matsumoto, Katsumi; Hosoda, Junya; Iguchi, Kouhei; Matsushita, Hirooki; Taguchi, Yuka; Horiguchi, Yoriko; Kimura, Kazuo
2017-05-25
The characteristics and prognosis of implanted pacemaker-identified new-onset atrial fibrillation (AF) in Japanese people has not been well evaluated.Methods and Results:A total of 395 consecutive patients with newly implanted pacemakers were retrospectively analyzed between January 2010 and December 2015 at Yokohama City University Hospital. Patients with a prior history of AF, VVI mode pacemaker, congenital heart disease, severe valvular heart disease, and cardiovascular surgery before pacemaker implantation were excluded. Among the remaining patients, 44 (21.3%) developed new AF during follow-up (mean follow-up, 1,115±651 days; range, 9-2,176 days). Patients with new-onset AF had a significantly higher CHADS 2 score (2.09±1.27 vs. 1.31±1.08, P<0.001) and CHA 2 DS 2 -VASc score (3.00±1.39 vs. 2.26±1.19, P<0.001) compared with those without new-onset AF. On Cox regression analysis only age at implantation was significantly correlated with new-onset AF. Interestingly, the incidence of hospitalization due to heart failure was significantly higher in the new-onset AF than in the without new-onset AF group. A total of 21.3% of pacemaker-implanted patients with high CHADS 2 and CHA 2 DS 2 -VASc scores developed new-onset AF during a mean follow-up of 3.1 years; and pacemaker-identified AF was associated with an increased risk of worsening heart failure.
Steinberg, Benjamin A; Hellkamp, Anne S; Lokhnygina, Yuliya; Patel, Manesh R; Breithardt, Günter; Hankey, Graeme J; Becker, Richard C; Singer, Daniel E; Halperin, Jonathan L; Hacke, Werner; Nessel, Christopher C; Berkowitz, Scott D; Mahaffey, Kenneth W; Fox, Keith A A; Califf, Robert M; Piccini, Jonathan P
2015-02-01
Anticoagulation prophylaxis for stroke is recommended for at-risk patients with either persistent or paroxysmal atrial fibrillation (AF). We compared outcomes in patients with persistent vs. paroxysmal AF receiving oral anticoagulation. Patients randomized in the Rivaroxaban Once Daily Oral Direct Factor Xa Inhibition Compared With Vitamin K Antagonism for Prevention of Stroke and Embolism Trial in Atrial Fibrillation (ROCKET-AF) trial (n = 14 264) were grouped by baseline AF category: paroxysmal or persistent. Multivariable adjustment was performed to compare thrombo-embolic events, bleeding, and death between groups, in high-risk subgroups, and across treatment assignment (rivaroxaban or warfarin). Of 14 062 patients, 11 548 (82%) had persistent AF and 2514 (18%) had paroxysmal AF. Patients with persistent AF were marginally older (73 vs. 72, P = 0.03), less likely female (39 vs. 45%, P < 0.0001), and more likely to have previously used vitamin K antagonists (64 vs. 56%, P < 0.0001) compared with patients with paroxysmal AF. In patients randomized to warfarin, time in therapeutic range was similar (58 vs. 57%, P = 0.94). Patients with persistent AF had higher adjusted rates of stroke or systemic embolism (2.18 vs. 1.73 events per 100-patient-years, P = 0.048) and all-cause mortality (4.78 vs. 3.52, P = 0.006). Rates of major bleeding were similar (3.55 vs. 3.31, P = 0.77). Rates of stroke or systemic embolism in both types of AF did not differ by treatment assignment (rivaroxaban vs. warfarin, Pinteraction = 0.6). In patients with AF at moderate-to-high risk of stroke receiving anticoagulation, those with persistent AF have a higher risk of thrombo-embolic events and worse survival compared with paroxysmal AF. © The Author 2014. Published by Oxford University Press on behalf of the European Society of Cardiology.
Simon, Jillian N.; Ziberna, Klemen; Casadei, Barbara
2016-01-01
Although the initiation, development, and maintenance of atrial fibrillation (AF) have been linked to alterations in myocyte redox state, the field lacks a complete understanding of the impact these changes may have on cellular signalling, atrial electrophysiology, and disease progression. Recent studies demonstrate spatiotemporal changes in reactive oxygen species production shortly after the induction of AF in animal models with an uncoupling of nitric oxide synthase activity ensuing in the presence of long-standing persistent AF, ultimately leading to a major shift in nitroso–redox balance. However, it remains unclear which radical or non-radical species are primarily involved in the underlying mechanisms of AF or which proteins are targeted for redox modification. In most instances, only free radical oxygen species have been assessed; yet evidence from the redox signalling field suggests that non-radical species are more likely to regulate cellular processes. A wider appreciation for the distinction of these species and how both species may be involved in the development and maintenance of AF could impact treatment strategies. In this review, we summarize how redox second-messenger systems are regulated and discuss the recent evidence for alterations in redox regulation in the atrial myocardium in the presence of AF, while identifying some critical missing links. We also examine studies looking at antioxidants for the prevention and treatment of AF and propose alternative redox targets that may serve as superior therapeutic options for the treatment of AF. PMID:26786158
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Wenjian; Scalettar, Richard T.; Huang, Edwin W.
The competition between antiferromagnetic (AF) order and singlet formation is a central phenomenon of the Kondo and periodic Anderson Hamiltonians and of the heavy fermion materials they describe. In this paper, we explore the effects of an additional conduction band on magnetism in these models, and, specifically, on changes in the AF-singlet quantum critical point (QCP) and the one particle and spin spectral functions. To understand the magnetic phase transition qualitatively, we first carry out a self-consistent mean field theory (MFT). The basic conclusion is that, at half filling, the coupling to the additional band stabilizes the AF phase tomore » larger f d hybridization V in the PAM. We also explore the possibility of competing ferromagnetic phases when this conduction band is doped away from half filling. Here, we next employ quantum Monte Carlo (QMC) which, in combination with finite size scaling, allows us to evaluate the position of the QCP using an exact treatment of the interactions. This approach confirms the stabilization of AF order, which occurs through an enhancement of the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction. QMC results for the spectral function A (q,ω) and dynamic spin structure factor χ (q,ω) yield additional insight into the AF-singlet competition and the low temperature phases.« less
Hu, Wenjian; Scalettar, Richard T.; Huang, Edwin W.; ...
2017-06-12
The competition between antiferromagnetic (AF) order and singlet formation is a central phenomenon of the Kondo and periodic Anderson Hamiltonians and of the heavy fermion materials they describe. In this paper, we explore the effects of an additional conduction band on magnetism in these models, and, specifically, on changes in the AF-singlet quantum critical point (QCP) and the one particle and spin spectral functions. To understand the magnetic phase transition qualitatively, we first carry out a self-consistent mean field theory (MFT). The basic conclusion is that, at half filling, the coupling to the additional band stabilizes the AF phase tomore » larger f d hybridization V in the PAM. We also explore the possibility of competing ferromagnetic phases when this conduction band is doped away from half filling. Here, we next employ quantum Monte Carlo (QMC) which, in combination with finite size scaling, allows us to evaluate the position of the QCP using an exact treatment of the interactions. This approach confirms the stabilization of AF order, which occurs through an enhancement of the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction. QMC results for the spectral function A (q,ω) and dynamic spin structure factor χ (q,ω) yield additional insight into the AF-singlet competition and the low temperature phases.« less
NASA Astrophysics Data System (ADS)
Levin, V. L.; Servali, A.; Dunham, B.; Klaser, M.
2015-12-01
A 1200 km long array of seismic observatories from James Bay to the Atlantic coast covers nearly 2 Ga in time, from the Archean Superior Province to the Paleozoic Appalachian Orogen. We use traditional (P-to-SV) receiver function analysis for detailed characterization of the lithospheric mantle along the array, focusing on the 5-15 s delay range where direct conversions from within the lithosphere and crustal multiples are expected.Superior craton sites show exceptionaly clear receiver functions dominated by the first crustal multiple. Also, a negative phase consistent with impedance decrease at the Mid-Lithospheric Discontinuity (~8 s delay) is observed north of 51°N, within the La Grande and Opinaca terranes of the Superior province. In the Opatica terrane further south we see a positive phase at similar delays instead. This implies a downward impedance increase 70-80 km deep within the lithosphere, consistent with the Hales discontinuity. In the Abitibi terrane just north of the Grenville Front we see evidence for two impedance drops in the 60-130 km depth range. Within the Proterozoic Grenvile province receiver functions vary with direction at individual sites, and lack regional consistency. Crustal multiples are noticeably weaker. South of 49°N we once again find negative phases in the 8-10 s delay range. While weak and directionally-dependent in the central Grenville province, these phases are clear near the Appalachian Front (AF), and are followed by positive phases, suggesting thin low-velocity layers in the lower part of the lithosphere. Similarity of receiver function signatures on opposite sides of the AF suggests continuity of the lithosphere beneath it.South of the AF and north of the Norumbega Fault Zone (NFZ) in Maine we find positive phases at ~10 s delays. The implied increase in impedance at ~75 km depth is puzzling. We also find previously-reported weak negative phases in the 6-8 s delay range. South of the NFZ a strong negative phase at ~9 s delay likely marks the bottom of the lithosphere.
Rhythm-based heartbeat duration normalization for atrial fibrillation detection.
Islam, Md Saiful; Ammour, Nassim; Alajlan, Naif; Aboalsamh, Hatim
2016-05-01
Screening of atrial fibrillation (AF) for high-risk patients including all patients aged 65 years and older is important for prevention of risk of stroke. Different technologies such as modified blood pressure monitor, single lead ECG-based finger-probe, and smart phone using plethysmogram signal have been emerging for this purpose. All these technologies use irregularity of heartbeat duration as a feature for AF detection. We have investigated a normalization method of heartbeat duration for improved AF detection. AF is an arrhythmia in which heartbeat duration generally becomes irregularly irregular. From a window of heartbeat duration, we estimate the possible rhythm of the majority of heartbeats and normalize duration of all heartbeats in the window based on the rhythm so that we can measure the irregularity of heartbeats for both AF and non-AF rhythms in the same scale. Irregularity is measured by the entropy of distribution of the normalized duration. Then we classify a window of heartbeats as AF or non-AF by thresholding the measured irregularity. The effect of this normalization is evaluated by comparing AF detection performances using duration with the normalization, without normalization, and with other existing normalizations. Sensitivity and specificity of AF detection using normalized heartbeat duration were tested on two landmark databases available online and compared with results of other methods (with/without normalization) by receiver operating characteristic (ROC) curves. ROC analysis showed that the normalization was able to improve the performance of AF detection and it was consistent for a wide range of sensitivity and specificity for use of different thresholds. Detection accuracy was also computed for equal rates of sensitivity and specificity for different methods. Using normalized heartbeat duration, we obtained 96.38% accuracy which is more than 4% improvement compared to AF detection without normalization. The proposed normalization method was found useful for improving performance and robustness of AF detection. Incorporation of this method in a screening device could be crucial to reduce the risk of AF-related stroke. In general, the incorporation of the rhythm-based normalization in an AF detection method seems important for developing a robust AF screening device. Copyright © 2016 Elsevier Ltd. All rights reserved.
Concomitant atrial fibrillation surgery for people undergoing cardiac surgery
Huffman, Mark D; Karmali, Kunal N; Berendsen, Mark A; Andrei, Adin-Cristian; Kruse, Jane; McCarthy, Patrick M; Malaisrie, S C
2016-01-01
Background People with atrial fibrillation (AF) often undergo cardiac surgery for other underlying reasons and are frequently offered concomitant AF surgery to reduce the frequency of short- and long-term AF and improve short- and long-term outcomes. Objectives To assess the effects of concomitant AF surgery among people with AF who are undergoing cardiac surgery on short-term and long-term (12 months or greater) health-related outcomes, health-related quality of life, and costs. Search methods Starting from the year when the first “maze” AF surgery was reported (1987), we searched the Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library (March 2016), MEDLINE Ovid (March 2016), Embase Ovid (March 2016), Web of Science (March 2016), the Database of Abstracts of Reviews of Effects (DARE, April 2015), and Health Technology Assessment Database (HTA, March 2016). We searched trial registers in April 2016. We used no language restrictions. Selection criteria We included randomised controlled trials evaluating the effect of any concomitant AF surgery compared with no AF surgery among adults with preoperative AF, regardless of symptoms, who were undergoing cardiac surgery for another indication. Data collection and analysis Two review authors independently selected studies and extracted data. We evaluated the risk of bias using the Cochrane ‘Risk of bias’ tool. We included outcome data on all-cause and cardiovascular-specific mortality, freedom from atrial fibrillation, flutter, or tachycardia off antiarrhythmic medications, as measured by patient electrocardiographic monitoring greater than three months after the procedure, procedural safety, 30-day rehospitalisation, need for post-discharge direct current cardioversion, health-related quality of life, and direct costs. We calculated risk ratios (RR) for dichotomous data with 95% confidence intervals (CI) using a fixed-effect model when heterogeneity was low (I2 ≤ 50%) and random-effects model when heterogeneity was high (I2 > 50%). We evaluated the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework to create a ‘Summary of findings’ table. Main results We found 34 reports of 22 trials (1899 participants) with five additional ongoing studies and three studies awaiting classification. All included studies were assessed as having high risk of bias across at least one domain. The effect of concomitant AF surgery on all-cause mortality was uncertain when compared with no concomitant AF surgery (7.0% versus 6.6%, RR 1.14, 95% CI 0.81 to 1.59, I2 = 0%, 20 trials, 1829 participants, low-quality evidence), but the intervention increased freedom from atrial fibrillation, atrial flutter, or atrial tachycardia off antiarrhythmic medications > three months (51.0% versus 24.1%, RR 2.04, 95% CI 1.63 to 2.55, I2 = 0%, eight trials, 649 participants, moderate-quality evidence). The effect of concomitant AF surgery on 30-day mortality was uncertain (2.3% versus 3.1%, RR 1.25 95% CI 0.71 to 2.20, I2 = 0%, 18 trials, 1566 participants, low-quality evidence), but the intervention increased the risk of permanent pacemaker implantation (6.0% versus 4.1%, RR 1.69, 95% CI 1.12 to 2.54, I2 = 0%, 18 trials, 1726 participants, moderate-quality evidence). Investigator-defined adverse events, including but limited to, need for surgical re-exploration or mediastinitis, were not routinely reported but were not different between the two groups (other adverse events: 24.8% versus 23.6%, RR 1.07, 95% CI 0.85 to 1.34, I2 = 45%, nine trials, 858 participants), but the quality of this evidence was very low. Authors’ conclusions For patients with AF undergoing cardiac surgery, there is moderate-quality evidence that concomitant AF surgery approximately doubles the risk of freedom from atrial fibrillation, atrial flutter, or atrial tachycardia off anti-arrhythmic drugs while increasing the risk of permanent pacemaker implantation. The effects on mortality are uncertain. Future, high-quality and adequately powered trials will likely affect the confidence on the effect estimates of AF surgery on clinical outcomes. PMID:27551927
Navarro, Claudio A; Orellana, Luis H; Mauriaca, Cecilia; Jerez, Carlos A
2009-10-01
The acidophilic Acidithiobacillus ferrooxidans can resist exceptionally high copper (Cu) concentrations. This property is important for its use in biomining processes, where Cu and other metal levels range usually between 15 and 100 mM. To learn about the mechanisms that allow A. ferrooxidans cells to survive in this environment, a bioinformatic search of its genome showed the presence of at least 10 genes that are possibly related to Cu homeostasis. Among them are three genes coding for putative ATPases related to the transport of Cu (A. ferrooxidans copA1 [copA1(Af)], copA2(Af), and copB(Af)), three genes related to a system of the resistance nodulation cell division family involved in the extraction of Cu from the cell (cusA(Af), cusB(Af), and cusC(Af)), and two genes coding for periplasmic chaperones for this metal (cusF(Af) and copC(Af)). The expression of most of these open reading frames was studied by real-time reverse transcriptase PCR using A. ferrooxidans cells adapted for growth in the presence of high concentrations of Cu. The putative A. ferrooxidans Cu resistance determinants were found to be upregulated when this bacterium was exposed to Cu in the range of 5 to 25 mM. These A. ferrooxidans genes conferred to Escherichia coli a greater Cu resistance than wild-type cells, supporting their functionality. The results reported here and previously published data strongly suggest that the high resistance of the extremophilic A. ferrooxidans to Cu may be due to part or all of the following key elements: (i) a wide repertoire of Cu resistance determinants, (ii) the duplication of some of these Cu resistance determinants, (iii) the existence of novel Cu chaperones, and (iv) a polyP-based Cu resistance system.
Glotzer, Taya V; Daoud, Emile G; Wyse, D George; Singer, Daniel E; Holbrook, Reece; Pruett, Khadeeja; Smith, Kenneth; Hilker, Christopher E
2006-01-01
Sustained atrial fibrillation (AF) is a common risk factor for stroke. While intermittent AF also appears to pose a substantial stroke risk, the quantitative relationship between the percentage of time spent in AF and stroke risk is poorly specified and "intermittent" AF is not the same as paroxysmal AF. Improved assessment of the impact of AF burden on stroke risk will allow more targeted and safer use of antithrombotic therapy. The primary objective of this study is to determine if AT/AF (all device detected atrial tachyarrhythmias, including atrial flutter, atrial fibrillation, and atrial tachycardia) burden over a 30 day period is an independent predictor of the occurrence of ischemic stroke, transient ischemic attack (TIA) and/or systemic embolism in subjects not receiving anticoagulation therapy. TRENDS is a prospective, post-market, non-randomized, multicenter study designed to enroll 3100 subjects who have an independent Class I/II indication for cardiac rhythm device implantation and who have demographic features suggestive of an increased risk for thromboembolic complications related to AT/AF. All implanted devices will have the ability to collect long-term AT/AF burden trending data and will be equivalently programmed to ensure consistent data collection. All subjects will be followed with device interrogations every 3 months and clinic visits every 6 months for 1 year. Subjects with a documented history of AT/AF prior to enrollment and those who develop AT/AF during the 12-month follow-up will be followed until the last subject enrolled in the study has completed their 24-month follow-up. The results of the TRENDS study should help clarify the implications of data retrieved from an implantable device with regard to the risk for thromboembolic complications from atrial arrhythmias, even in the absence of symptoms.
Gasparini, Maurizio; Auricchio, Angelo; Metra, Marco; Regoli, François; Fantoni, Cecilia; Lamp, Barbara; Curnis, Antonio; Vogt, Juergen; Klersy, Catherine
2008-01-01
Aims To investigate the effects of cardiac resynchronization therapy (CRT) on survival in heart failure (HF) patients with permanent atrial fibrillation (AF) and the role of atrio-ventricular junction (AVJ) ablation in these patients. Methods and results Data from 1285 consecutive patients implanted with CRT devices are presented: 1042 patients were in sinus rhythm (SR) and 243 (19%) in AF. Rate control in AF was achieved by either ablating the AVJ in 118 patients (AVJ-abl) or prescribing negative chronotropic drugs (AF-Drugs). Compared with SR, patients with AF were significantly older, more likely to be non-ischaemic, with higher ejection fraction, shorter QRS duration, and less often received ICD back-up. During a median follow-up of 34 months, 170/1042 patients in SR and 39/243 in AF died (mortality: 8.4 and 8.9 per 100 person-year, respectively). Adjusted hazard ratios were similar for all-cause and cardiac mortality [0.9 (0.57–1.42), P = 0.64 and 1.00 (0.60–1.66) P = 0.99, respectively]. Among AF patients, only 11/118 AVJ-abl patients died vs. 28/125 AF-Drugs patients (mortality: 4.3 and 15.2 per 100 person-year, respectively, P < 0.001). Adjusted hazard ratios of AVJ-abl vs. AF-Drugs was 0.26 [95% confidence interval (CI) 0.09–0.73, P = 0.010] for all-cause mortality, 0.31 (95% CI 0.10–0.99, P = 0.048) for cardiac mortality, and 0.15 (95% CI 0.03–0.70, P = 0.016) for HF mortality. Conclusion Patients with HF and AF treated with CRT have similar mortality compared with patients in SR. In AF, AVJ ablation in addition to CRT significantly improves overall survival compared with CRT alone, primarily by reducing HF death. PMID:18390869
Dabigatran affects thrombin-dependent platelet aggregation after a week-long therapy.
Sokol, Juraj; Nehaj, Frantisek; Ivankova, Jela; Mokan, Michal; Mokan, Marian; Stasko, Jan
2018-05-29
Dabigatran is a direct thrombin inhibitor. As the main adverse event is bleeding, it is relevant whether dabigatran has additional effects on platelet function. If so, it could affect the bleeding risk. We aimed to assess in vitro aggregation in patients with atrial fibrillation (AF) receiving dabigatran. We evaluated 32 AF patients treated with dabigatran (study group) and 18 non-anticoagulated non-AF blood donors (control group). We assessed light transmittance platelet aggregation (LTA) with 100 nmol/L γ-thrombin in both groups. The LTA was performed at two time-points in our dabigatran group of patients. The thrombin-induced platelet aggregation was significantly lower two hours after dabigatran was taken compared to baseline measurement (9% ± 6% vs. 29% ± 21%) in our study group. Moreover, we observed that the baseline value of platelet aggregation in patients on dabigatran treatment was significantly lower compared to healthy volunteers (29% ± 21% vs. 89 ± 8). However, one subanalysis showed that this significant reduction in platelet aggregation at baseline was only observed in patients who received dabigatran for over a week. The thrombin-induced platelet aggregation is reduced in non-valvular AF patients receiving dabigatran after a week-long therapy.
Impurities near an antiferromagnetic-singlet quantum critical point
Mendes-Santos, T.; Costa, N. C.; Batrouni, G.; ...
2017-02-15
Heavy-fermion systems and other strongly correlated electron materials often exhibit a competition between antiferromagnetic (AF) and singlet ground states. We examine the effect of impurities in the vicinity of such an AF-singlet quantum critical point (QCP), through an appropriately defined “impurity susceptibility” χimp, using exact quantum Monte Carlo simulations. Our key finding is a connection within a single calculational framework between AF domains induced on the singlet side of the transition and the behavior of the nuclear magnetic resonance (NMR) relaxation rate 1/T1. Furthermore, we show that local NMR measurements provide a diagnostic for the location of the QCP, whichmore » agrees remarkably well with the vanishing of the AF order parameter and large values of χimp.« less
Quantitative Autofluorescence Intensities in Acute Zonal Occult Outer Retinopathy vs Healthy Eyes
Boudreault, Katherine; Schuerch, Kaspar; Zhao, Jin; Lee, Winston; Cabral, Thiago; Yannuzzi, Lawrence A.; Tsang, Stephen H.; Sparrow, Janet R.
2018-01-01
IMPORTANCE Acute zonal occult outer retinopathy (AZOOR) remains a challenging diagnosis. Early recognition of the disease depends on advances in imaging modalities that can improve phenotyping and contribute to the understanding of the underlying pathogenesis. OBJECTIVES To expand the range of approaches available to assist in the identification of AZOOR by multimodal imaging and to analyze the fundus lesions by quantifying short-wavelength fundus autofluorescence (quantitative fundus autofluorescence [qAF]) and spectral-domain optical coherence tomography. DESIGN, SETTING, AND PARTICIPANTS In this observational study, patients underwent imaging at Columbia University Medical Center between November 2010 and March 2016 and were analyzed between September 2015 and August 2016. Six patients diagnosed as having AZOOR were studied by qAF and spectral-domain optical coherence tomography and were compared with 30 age and race/ethnicity–matched controls from a database of 277 healthy control eyes. MAIN OUTCOMES AND MEASURES In unaffected regions of the macula, qAF was calculated within predetermined circularly arranged segments (qAF8). In addition, qAF was measured within specified regions of interest positioned at the autofluorescent lesion border (AZOOR line). Electroretinograms and electro-oculograms were recorded in 5 of 6 patients. RESULTS Among 6 patients (age range, 26–61 years; 4 female; 4 of white race/ethnicity, 1 Asian, and 1 Hispanic), 5 exhibited an autofluorescent AZOOR line in short-wavelength fundus autofluorescence images, delineating the peripapillary lesion. The mean (SD) region-of-interest qAF measured on the AZOOR line was 60 (26) times higher than in healthy control eyes (P = .03) at equivalent fundus locations. The qAF8 within nondiseased macular regions were within the normal range. At the lesion border, spectral-domain optical coherence tomography revealed a loss of outer retinal integrity in all patients. Single-flash cone b-wave latency and 30-Hz flicker latency responses were significantly delayed bilaterally. Lesions with smooth, homogeneous borders exhibited only minimal expansion in size over time, while the lesion in a patient with a heterogeneous border progressed more rapidly. CONCLUSIONS AND RELEVANCE The finding that qAF is elevated at the border between diseased and nondiseased retina in patients with AZOOR contributes to the understanding of the natural history of the disease. PMID:29075777
Skeppholm, Mika; Al-Aieshy, Fadiea; Berndtsson, Maria; Al-Khalili, Faris; Rönquist-Nii, Yuko; Söderblom, Lisbeth; Östlund, Annika Y; Pohanka, Anton; Antovic, Jovan; Malmström, Rickard E
2015-07-01
The direct factor-Xa inhibitor apixaban is approved e.g. for the prevention of stroke in patients with atrial fibrillation (AF). Although routine monitoring of apixaban therapy is currently not recommended, selective monitoring could be useful to optimize efficacy and safety in certain clinical situations. We studied the exposure and effect of apixaban using different laboratory methods in a clinical setting with a well-defined cohort of AF patients. Seventy AF patients (72±7.4years, 64 % men, mean CHADS2 score 1.7) treated with apixaban 2.5 (n=10) or 5mg BID (n=60). Trough plasma apixaban concentrations determined by liquid chromatography-tandem mass-spectrometry (LC-MS/MS) were compared to the coagulation assays Anti-factor Xa, PT-INR and aPTT. The apixaban plasma concentration determined by LC-MS/MS varied more than 10-fold overall. The range was between 15-83 and 29-186ng/mL for the 2.5mg BID and 5mg BID respectively, with patients receiving 5mg BID having significantly higher apixaban concentrations (p<0.001). A strong correlation between LC-MS/MS and anti-FXa-assay was found (p<0.001), while aPTT and PT-INR were not sensitive enough. There were no significant correlations between gender, creatinine clearance, body weight or age and apixaban exposure. Anti-FXa-assay performed well upon apixaban concentrations in a normal exposure range. Still LC-MS/MS remains the "gold standard" method, covering also low concentrations. Compared to clinical trials, we observed relatively lower apixaban exposure and a more pronounced difference between high and low dose. Additional information regarding apixaban exposure and benefit-risk profile is needed in order to individualize treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Salam, Amar M; Al, Binali Hajar A; Singh, Rajvir; Gehani, Abdurrazzak; Asaad, Nidal; Al-Qahtani, Awad; Suwaidi, Jassim Al
2013-04-01
Recent evidence suggests that there are ethnic variations in atrial fibrillation (AF) susceptibility and incidence following acute myocardial infarction (AMI). The aim of this study was to evaluate the incidence and predictors of AF in the setting of AMI in Middle Eastern Arab and South Asian patients and its impact on in-hospital morbidity and mortality. A retrospective analysis of a prospective registry of all patients hospitalized with AMI in the state of Qatar from 1991 through 2010 was made. Clinical characteristics and outcomes of AMI patients with and without AF were compared. Sub-analysis according to ethnicity was also performed. During the 20-year period; a total of 12,881 patients were hospitalized with AMI. Of these 5028 were Arabs and 5985 were South Asians. A total of 227 had AF during hospitalization with an overall incidence of 1.8% (156 Arabs; incidence 3.1% and 48 South Asians; incidence 0.8%). The mean age of AF patients was 65 years (Arabs 69, South Asians 54). Patients with AF were significantly older and had more cardiovascular co-morbidities than patients without AF, and were more likely to have non-ST elevation AMI on presentation. Patients with AF had significantly higher in-hospital mortality rate (20.3% versus 7.1%; P=0.001) and stroke rates (1.8% versus 0.3%; P=0.001) when compared to patients without AF. Age was the only independent predictor of AF development in patients with AMI in our study. Our study reports variability in the prevalence of AF among AMI patients according to ethnicity using a 20-year registry from a Middle Eastern country. Advancing age was the major independent predictor of AF in our AMI patients. Further prospective studies are required evaluating optimal therapeutic approaches for these high-risk patients in order to reduce the high mortality observed.
The splicing factor U2AF65 stabilizes TRF1 protein by inhibiting its ubiquitin-dependent proteolysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jeonghee; Chung, In Kwon, E-mail: topoviro@yonsei.ac.kr
Highlights: •Identification of U2AF65 as a novel TRF1-interacting protein. •U2AF65 stabilizes TRF1 protein by inhibiting its ubiquitin-dependent proteolysis. •U2AF65 interferes with the interaction between TRF1 and Fbx4. •U2AF65 represents a new route for modulating TRF1 function at telomeres. -- Abstract: The human telomeric protein TRF1 is a component of the six-subunit protein complex shelterin, which provides telomere protection by organizing the telomere into a high-order structure. TRF1 functions as a negative regulator of telomere length by controlling the access of telomerase to telomeres. Thus, the cellular abundance of TRF1 at telomeres should be maintained and tightly regulated to ensure propermore » telomere function. Here, we identify U2 small nuclear ribonucleoprotein (snRNP) auxiliary factor 65 (U2AF65), an essential pre-mRNA splicing factor, as a novel TRF1-interacting protein. U2AF65 interacts with TRF1 in vitro and in vivo and is capable of stabilizing TRF1 protein by inhibiting its ubiquitin-dependent proteolysis. We also found that U2AF65 interferes with the interaction between TRF1 and Fbx4, an E3 ubiquitin ligase for TRF1. Depletion of endogenous U2AF65 expression by short interfering RNA (siRNA) reduced the stability of endogenous TRF1 whereas overexpression of U2AF65 significantly extended the half-life of TRF1. These findings demonstrate that U2AF65 plays a critical role in regulating the level of TRF1 through physical interaction and ubiquitin-mediated proteolysis. Hence, U2AF65 represents a new route for modulating TRF1 function at telomeres.« less
A review of apixaban for stroke prevention in atrial fibrillation: insights from ARISTOTLE.
Hess, Connie N; Al-Khatib, Sana M; Granger, Christopher B; Lopes, Renato
2013-09-01
Atrial fibrillation (AF) is associated with significant mortality and morbidity, and stroke represents the most-feared complication. Consequently, AF treatment has focused on thromboprophylaxis, with warfarin as the mainstay of therapy. However, concerns over ease of use and safety have limited its use. Three novel oral anticoagulants have been approved for use in stroke prevention in AF based on randomized data: 1) dabigatran, studied in Randomized Evaluation of Long-term Anticoagulation Therapy (RE-LY); 2) rivaroxaban, studied in Rivaroxaban Once-daily, Oral, Direct Factor Xa Inhibition Compared with Vitamin K Antagonism for Prevention of Stroke and Embolism Trial in Atrial Fibrillation (ROCKET AF); and 3) apixaban, studied in Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation (ARISTOTLE). In this review, we focus on apixaban and discuss subgroup analyses that have been performed in the three trials comparing novel oral anticoagulants with warfarin. We conclude with recommendations regarding further investigations.
Webster, Fiona; Patel, Jigisha; Rice, Kathleen; Baxter, Nancy; Paszat, Lawrence; Rabeneck, Linda
2016-01-01
Background. Audit and feedback (A/F) reports are one of the few knowledge translation activities that can effect change in physician behavior. In this study, we pilot-tested an endoscopist A/F report to elicit opinions about the proposed report's usability, acceptability and usefulness, and implications for knowledge translation. Methods. Semi-structured qualitative interviews were conducted with eleven endoscopists in Ontario, Canada. We tested an A/F report template comprising 9 validated, accepted colonoscopy quality indicators populated with simulated data. Interview transcripts were coded using techniques such as constant comparison and themes were identified inductively over several team meetings. Results. Four interrelated themes were identified: (1) overall perceptions of the A/F report; (2) accountability and consequences for poor performance; (3) motivation to change/improve skills; and (4) training for performance enhancement and available resources. The A/F report was well received; however, participants cited some possible threats to the report's effectiveness including the perceived threat of loss of privileges or licensing and the potential for the data to be dismissed. Conclusions. Participants agreed that A/F has the potential to improve colonoscopy performance. However, in order to be effective in changing physician behavior, A/F must be thoughtfully implemented with attention to the potential concerns of its recipients. PMID:27722149
Webster, Fiona; Patel, Jigisha; Rice, Kathleen; Baxter, Nancy; Paszat, Lawrence; Rabeneck, Linda; Tinmouth, Jill
2016-01-01
Background . Audit and feedback (A/F) reports are one of the few knowledge translation activities that can effect change in physician behavior. In this study, we pilot-tested an endoscopist A/F report to elicit opinions about the proposed report's usability, acceptability and usefulness, and implications for knowledge translation. Methods . Semi-structured qualitative interviews were conducted with eleven endoscopists in Ontario, Canada. We tested an A/F report template comprising 9 validated, accepted colonoscopy quality indicators populated with simulated data. Interview transcripts were coded using techniques such as constant comparison and themes were identified inductively over several team meetings. Results . Four interrelated themes were identified: (1) overall perceptions of the A/F report; (2) accountability and consequences for poor performance; (3) motivation to change/improve skills; and (4) training for performance enhancement and available resources. The A/F report was well received; however, participants cited some possible threats to the report's effectiveness including the perceived threat of loss of privileges or licensing and the potential for the data to be dismissed. Conclusions . Participants agreed that A/F has the potential to improve colonoscopy performance. However, in order to be effective in changing physician behavior, A/F must be thoughtfully implemented with attention to the potential concerns of its recipients.
Bellmann, Barbara; Lin, Tina; Ruppersberg, Peter; Zettwitz, Marit; Guttmann, Selma; Tscholl, Verena; Nagel, Patrick; Roser, Mattias; Landmesser, Ulf; Rillig, Andreas
2018-05-09
The optimal ablation approach for the treatment of persistent atrial fibrillation (AF) is still under debate; however, the identification and elimination of AF sources is thought to play a key role. Currently available technologies for the identification of AF sources are not able to differentiate between active rotors or focal impulse (FI) and passive circular turbulences as generated by the interaction of a wave front with a functional obstacle such as fibrotic tissue. This study introduces electrographic flow (EGF) mapping as a novel technology for the identification and characterization of AF sources in humans. Twenty-five patients with AF (persistent: n = 24, long-standing persistent: n = 1; mean age 70.0 ± 8.3 years, male: n = 17) were included in this prospective study. Focal impulse and Rotor-Mapping (FIRM) was performed in addition to pulmonary vein isolation using radiofrequency in conjunction with a 3D-mapping-system. One-minute epochs were exported from the EP-recording-system and re-analyzed using EGF mapping after the procedure. 44 potential AF sources (43 rotors and one FI) were identified with FIRM and 39 of these rotors were targeted for ablation. EGF mapping verified 40 of these patterns and identified 24/40 (60%) as active sources while 16/40 (40%) were classified as passive circular turbulences. Four rotors were not identified by EGF mapping. EGF is the first method to identify active AF sources during AF ablation procedures in humans and discriminate them from passive rotational phenomena, which occur if the excitation wavefront passes conduction bariers. EGF mapping may allow improved guidance of AF ablation procedures.
Hwang, Minki; Song, Jun-Seop; Lee, Young-Seon; Li, Changyong; Shim, Eun Bo; Pak, Hui-Nam
2016-01-01
Although rotors have been considered among the drivers of atrial fibrillation (AF), the rotor definition is inconsistent. We evaluated the nature of rotors in 2D and 3D in- silico models of persistent AF (PeAF) by analyzing phase singularity (PS), dominant frequency (DF), Shannon entropy (ShEn), and complex fractionated atrial electrogram cycle length (CFAE-CL) and their ablation. Mother rotor was spatiotemporally defined as stationary reentries with a meandering tip remaining within half the wavelength and lasting longer than 5 s. We generated 2D- and 3D-maps of the PS, DF, ShEn, and CFAE-CL during AF. The spatial correlations and ablation outcomes targeting each parameter were analyzed. 1. In the 2D PeAF model, we observed a mother rotor that matched relatively well with DF (>9 Hz, 71.0%, p<0.001), ShEn (upper 2.5%, 33.2%, p<0.001), and CFAE-CL (lower 2.5%, 23.7%, p<0.001). 2. The 3D-PeAF model also showed mother rotors that had spatial correlations with DF (>5.5 Hz, 39.7%, p<0.001), ShEn (upper 8.5%, 15.1%, p <0.001), and CFAE (lower 8.5%, 8.0%, p = 0.002). 3. In both the 2D and 3D models, virtual ablation targeting the upper 5% of the DF terminated AF within 20 s, but not the ablations based on long-lasting PS, high ShEn area, or lower CFAE-CL area. Mother rotors were observed in both 2D and 3D human AF models. Rotor locations were well represented by DF, and their virtual ablation altered wave dynamics and terminated AF.
Hwang, Minki; Song, Jun-Seop; Lee, Young-Seon; Li, Changyong; Shim, Eun Bo; Pak, Hui-Nam
2016-01-01
Background Although rotors have been considered among the drivers of atrial fibrillation (AF), the rotor definition is inconsistent. We evaluated the nature of rotors in 2D and 3D in- silico models of persistent AF (PeAF) by analyzing phase singularity (PS), dominant frequency (DF), Shannon entropy (ShEn), and complex fractionated atrial electrogram cycle length (CFAE-CL) and their ablation. Methods Mother rotor was spatiotemporally defined as stationary reentries with a meandering tip remaining within half the wavelength and lasting longer than 5 s. We generated 2D- and 3D-maps of the PS, DF, ShEn, and CFAE-CL during AF. The spatial correlations and ablation outcomes targeting each parameter were analyzed. Results 1. In the 2D PeAF model, we observed a mother rotor that matched relatively well with DF (>9 Hz, 71.0%, p<0.001), ShEn (upper 2.5%, 33.2%, p<0.001), and CFAE-CL (lower 2.5%, 23.7%, p<0.001). 2. The 3D-PeAF model also showed mother rotors that had spatial correlations with DF (>5.5 Hz, 39.7%, p<0.001), ShEn (upper 8.5%, 15.1%, p <0.001), and CFAE (lower 8.5%, 8.0%, p = 0.002). 3. In both the 2D and 3D models, virtual ablation targeting the upper 5% of the DF terminated AF within 20 s, but not the ablations based on long-lasting PS, high ShEn area, or lower CFAE-CL area. Conclusion Mother rotors were observed in both 2D and 3D human AF models. Rotor locations were well represented by DF, and their virtual ablation altered wave dynamics and terminated AF. PMID:26909492
Risk of ischemic stroke after atrial fibrillation diagnosis: A national sample cohort
Son, Mi Kyoung; Lim, Nam-Kyoo; Kim, Hyung Woo
2017-01-01
Atrial fibrillation (AF) is a major risk factor for ischemic stroke and associated with a 5-fold higher risk of stroke. In this retrospective cohort study, the incidence of and risk factors for ischemic stroke in patients with AF were identified. All patients (≥30 years old) without previous stroke who were diagnosed with AF in 2007–2013 were selected from the National Health Insurance Service-National Sample Cohort. To identify factors that influenced ischemic stroke risk, Cox proportional hazard regression analysis was conducted. During a mean follow-up duration of 3.2 years, 1022 (9.6%) patients were diagnosed with ischemic stroke. The overall incidence rate of ischemic stroke was 30.8/1000 person-years. Of all the ischemic stroke that occurred during the follow-up period, 61.0% occurred within 1-year after AF diagnosis. Of the patients with CHA2DS2-VASc score of ≥2, only 13.6% were receiving warfarin therapy within 30 days after AF diagnosis. Relative to no antithrombotic therapy, warfarin treatment for >90 days before the index event (ischemic stroke in stroke patients and death/study end in non-stroke patients) associated with decreased ischemic stroke risk (Hazard Ratio = 0.41, 95%confidence intervals = 0.32–0.53). Heart failure, hypertension, and diabetes mellitus associated with greater ischemic stroke risk. AF patients in Korea had a higher ischemic stroke incidence rate than patients in other countries and ischemic stroke commonly occurred at early phase after AF diagnosis. Long-term (>90 days) continuous warfarin treatment may be beneficial for AF patients. However, warfarin treatment rates were very low. To prevent stroke, programs that actively detect AF and provide anticoagulation therapy are needed. PMID:28636620
Selmer, Christian; Hansen, Morten Lock; Olesen, Jonas Bjerring; Mérie, Charlotte; Lindhardsen, Jesper; Olsen, Anne-Marie Schjerning; Madsen, Jesper Clausager; Schmidt, Ulla; Faber, Jens; Hansen, Peter Riis; Pedersen, Ole Dyg; Torp-Pedersen, Christian; Gislason, Gunnar Hilmar
2013-01-01
To examine the long-term risk of hyperthyroidism in patients admitted to hospital with new-onset AF. Hyperthyroidism is a well-known risk factor for atrial fibrillation (AF), but it is unknown whether new-onset AF predicts later-occurring hyperthyroidism. All patients admitted with new-onset AF in Denmark from 1997-2009, and their present and subsequent use of anti-thyroid medication was identified by individual-level linkage of nationwide registries. Patients with previous thyroid diagnosis or thyroid medication use were excluded. Development of hyperthyroidism was assessed as initiation of methimazole or propylthiouracil up to a 13-year period. Risk of hyperthyroidism was analysed by Poisson regression models adjusted for important confounders such as amiodarone treatment. Non-AF individuals from the general population served as reference. A total of 145,623 patients with new-onset AF were included (mean age 66.4 years [SD ±13.2] and 55.3% males) of whom 3% (4,620 events; 62.2% women) developed hyperthyroidism in the post-hospitalization period compared to 1% (48,609 events; 82% women) in the general population (n = 3,866,889). In both women and men we found a significantly increased risk of hyperthyroidism associated with new-onset AF compared to individuals in the general population. The highest risk was found in middle-aged men and was consistently increased throughout the 13-year period of observation. The results were confirmed in a substudy analysis of 527,352 patients who had thyroid screening done. New-onset AF seems to be a predictor of hyperthyroidism. Increased focus on subsequent risk of hyperthyroidism in patients with new-onset AF is warranted.
Selmer, Christian; Hansen, Morten Lock; Olesen, Jonas Bjerring; Mérie, Charlotte; Lindhardsen, Jesper; Olsen, Anne-Marie Schjerning; Madsen, Jesper Clausager; Schmidt, Ulla; Faber, Jens; Hansen, Peter Riis; Pedersen, Ole Dyg; Torp-Pedersen, Christian; Gislason, Gunnar Hilmar
2013-01-01
Aims To examine the long-term risk of hyperthyroidism in patients admitted to hospital with new-onset AF. Hyperthyroidism is a well-known risk factor for atrial fibrillation (AF), but it is unknown whether new-onset AF predicts later-occurring hyperthyroidism. Methods and Results All patients admitted with new-onset AF in Denmark from 1997–2009, and their present and subsequent use of anti-thyroid medication was identified by individual-level linkage of nationwide registries. Patients with previous thyroid diagnosis or thyroid medication use were excluded. Development of hyperthyroidism was assessed as initiation of methimazole or propylthiouracil up to a 13-year period. Risk of hyperthyroidism was analysed by Poisson regression models adjusted for important confounders such as amiodarone treatment. Non-AF individuals from the general population served as reference. A total of 145,623 patients with new-onset AF were included (mean age 66.4 years [SD ±13.2] and 55.3% males) of whom 3% (4,620 events; 62.2% women) developed hyperthyroidism in the post-hospitalization period compared to 1% (48,609 events; 82% women) in the general population (n = 3,866,889). In both women and men we found a significantly increased risk of hyperthyroidism associated with new-onset AF compared to individuals in the general population. The highest risk was found in middle-aged men and was consistently increased throughout the 13-year period of observation. The results were confirmed in a substudy analysis of 527,352 patients who had thyroid screening done. Conclusion New-onset AF seems to be a predictor of hyperthyroidism. Increased focus on subsequent risk of hyperthyroidism in patients with new-onset AF is warranted. PMID:23469097
Leiria, Tiago Luiz Luz; Glavinovic, Tamara; Armour, J Andrew; Cardinal, René; de Lima, Gustavo Glotz; Kus, Teresa
2011-04-26
In canines, excessive activation of select mediastinal nerve inputs to the intrinsic cardiac nervous system induces atrial fibrillation (AF). Since ablation of neural elements is proposed as an adjunct to circumferential pulmonary vein ablation for AF, we investigated the short and long-term effects of mediastinal nerve ablation on AF inducibility. Under general anesthesia, in 11 dogs several mediastinal nerve sites were identified on the superior vena cava that, when stimulated electrically during the atrial refractory period, reproducibly initiated AF. Cryoablation of one nerve site was then performed and inducibility retested early (1-2 months post Cryo; n=7) or late (4 months post Cryo; n=4). Four additional dogs that underwent a sham procedure were retested 1 to 2 months post-surgery. Stimulation induced AF at 91% of nerve sites tested in control versus 21% nerve sites early and 54% late post-ablation (both P<0.05). Fewer stimuli were required to induce AF in controls versus the Early Cryo group; this capacity returned to normal values in the Late Cryo group. AF episodes were longer in control versus the Early or Late Cryo groups. Heart rate responses to vagal or stellate ganglion stimulation, as well as to local nicotine infusion into the right coronary artery, were similar in all groups. In conclusion, focal damage to intrinsic cardiac neuronal inputs causes short-term stunning of neuronal inducibility of AF without major loss of overall adrenergic or cholinergic efferent neuronal control. That recovery of AF inducibility occurs rapidly post-surgery indicates the plasticity of intrathoracic neuronal elements to focal injury. Copyright © 2011 Elsevier B.V. All rights reserved.
Kiuchi, Márcio G; Chen, Shaojie; E Silva, Gustavo R; Paz, Luis M R; Kiuchi, Tetsuaki; de Paula Filho, Ary G; Souto, Gladyston L L
2016-12-01
Atrial fibrillation (AF) commonly occurs in association with chronic kidney disease (CKD), resulting in adverse outcomes. Combining pulmonary vein isolation (PVI) and renal sympathetic denervation (RSD) may reduce the recurrence of AF in patients with CKD and hypertension. We considered that RSD could reduce the recurrence of AF in patients with CKD by modulating sympathetic hyperactivity. Our goal was to compare the impact of PVI + RSD with that of PVI alone in patients with concurrent AF and CKD. This was a single-center, prospective, longitudinal, randomized, double-blind study. Forty-five patients with controlled hypertension, symptomatic paroxysmal AF and/or persistent AF, stage 2 or 3 CKD, and a dual-chamber pacemaker were enrolled from January 2014 to January 2015. We assessed the 30-second recurrence of AF recorded by the pacemaker, 24-hour ambulatory blood pressure measurements, estimated glomerular filtration rate, albuminuria, echocardiographic parameters, and safety of RSD. No patient developed procedural or other complications. The ambulatory blood pressure measurements did not differ within the PVI + RSD group or between the PVI + RSD and PVI groups throughout the study. Significantly more patients in the PVI + RSD group than in the PVI group were free of AF at the 12-month follow-up evaluation. The PVI group had an unacceptable response to ablation with respect to changes in echocardiographic parameters, whereas these parameters improved in the PVI + RSD group. PVI + RSD were associated with a lower AF recurrence rate than PVI alone; it also improved renal function and some echocardiographic parameters. These encouraging data will serve as baseline information for further long-term studies on larger patient populations.
Narayan, Sanjiv M.; Shivkumar, Kalyanam; Krummen, David E.; Miller, John M.; Rappel, Wouter-Jan
2013-01-01
Background The foundation for successful arrhythmia ablation is the mapping of electric propagation to identify underlying mechanisms. In atrial fibrillation (AF), however, mapping is difficult so that ablation has often targeted electrogram features, with mixed results. We hypothesized that wide field-of-view (panoramic) mapping of both atria would identify causal mechanisms for AF and allow interpretation of local electrogram features, including complex fractionated atrial electrograms (CFAE). Methods and Results Contact mapping was performed using biatrial multipolar catheters in 36 AF subjects (29 persistent). Stable AF rotors (spiral waves) or focal sources were seen in 35 of 36 cases and targeted for ablation (focal impulse and rotor modulation) before pulmonary vein isolation. In 31 of 36 subjects (86.1%), AF acutely terminated (n=20; 16 to sinus rhythm) or organized (n=11; 19±8% slowing) with 2.5 minutes focal impulse and rotor modulation (interquartile range, 1.0–3.1) at one source, defined as the primary source. Subjects exhibited 2.1±1.0 concurrent AF sources of which the primary, by phase mapping, precessed in limited areas (persistent 2.5±1.7 versus paroxysmal 1.7±0.5 cm2; P=0.30). Notably, source regions showed mixed electrogram amplitudes and CFAE grades that did not differ from surrounding atrium (P=NS). AF sources were not consistently surrounded by CFAE (P=0.67). Conclusions Stable rotors and focal sources for human AF were revealed by contact panoramic mapping (focal impulse and rotor modulation mapping), but not by electrogram footprints. AF sources precessed within areas of ≈2 cm2, with diverse voltage characteristics poorly correlated with CFAE. Most CFAE sites lie remote from AF sources and are not suitable targets for catheter ablation of AF. PMID:23392583
Spin-motive Force Induced by Domain Wall Dynamics in the Antiferromagnetic Spin Valve
NASA Astrophysics Data System (ADS)
Sugano, Ryoko; Ichimura, Masahiko; Takahashi, Saburo; Maekawa, Sadamichi; Crest Collaboration
2014-03-01
In spite of no net magnetization in antiferromagnetic (AF) textures, the local magnetic properties (Neel magnetization) can be manipulated in a similar fashion to ferromagnetic (F) ones. It is expected that, even in AF metals, spin transfer torques (STTs) lead to the domain wall (DW) motion and that the DW motion induces spin-motive force (SMF). In order to study the Neel magnetization dynamics and the resultant SMF, we treat the nano-structured F1/AF/F2 junction. The F1 and F2 leads behave as a spin current injector and a detector, respectively. Each F lead is fixed in the different magnetization direction. Torsions (DW in AF) are introduced reflecting the fixed magnetization of two F leads. We simulated the STT-induced Neel magnetization dynamics with the injecting current from F1 to F2 and evaluate induced SMF. Based on the adiabatic electron dynamics in the AF texture, Langevin simulations are performed at finite temperature. This research was supported by JST, CREST, Japan.
NASA Astrophysics Data System (ADS)
Park, S.-H.; Liu, B.-Q.; Behal, D.; Pedersen, B.; Schneidewind, A.
2018-04-01
The low temperature antiferromagnetic (AF) phase of MnWO4 (the so-called AF1 phase) exhibits different spin-canting configurations at two Mn2+ sublattices of the (3 + 1)-dimensional magnetic structure. The suggested superspace group {{\\boldsymbol P}}2.1^\\prime(α, 1/2, γ)0s is a significant consequence of the polar space group {{\\boldsymbol P}} 2 true for the nuclear structure of MnWO4. Density functional theory calculations showed that its ground state prefers this two spin-canting system. The structural difference between two independent atomic sites for Mn (Mn a , Mn b ) is too small to allow microscopically detectable electric polarisation. However, this hidden intrinsic polar character allows AF1 two commensurately modulated spin-canting textures. This is considered as the prerequisite onset of the improper ferroelectricity enhanced by the helical spin order in the multiferroic phase AF2 of MnWO4.
Chen, Minjie; Li, Yanjun; Zhang, Li; Wang, Jianying; Zheng, Chunli; Zhang, Xuefeng
2015-02-01
Acidithiobacillus ferrooxidans plays a critical role in metal solubilization in the biomining industry, and occupies an ecological niche characterized by high acidity and high concentrations of toxic heavy metal ions. In order to investigate the possible metal resistance mechanism, the cellular distribution of cadmium was tested. The result indicated that Cd(2+) entered the cells upon initial exposure resulting in increased intracellular concentrations, followed by its excretion from the cells during subsequent growth and adaptation. Sequence homology analyses were used to identify 10 genes predicted to participate in heavy metal homeostasis, and the expression of these genes was investigated in cells cultured in the presence of increasing concentrations of toxic divalent cadmium (Cd(2+)). The results suggested that one gene (cmtR A.f ) encoded a putative Cd(2+)/Pb(2+)-responsive transcriptional regulator; four genes (czcA1 A.f , czcA2 A.f , czcB1 A.f ; and czcC1 A.f ) encoded heavy metal efflux proteins for Cd(2+); two genes (cadA1 A.f and cadB1 A.f ) encoded putative cation channel proteins related to the transport of Cd(2+). No significant enhancement of gene expression was observed at low concentrations of Cd(2+) (5 mM) and most of the putative metal resistance genes were up-regulated except cmtR A.f , cadB3 A.f ; and czcB1 A.f at higher concentrations (15 and 30 mM) according to real-time polymerase chain reaction. A model was developed for the mechanism of resistance to cadmium ions based on homology analyses of the predicted genes, the transcription of putative Cd(2+) resistance genes, and previous work.
Fudim, Marat; Liu, Peter R; Shrader, Peter; Blanco, Rosalia G; Allen, Larry A; Fonarow, Gregg C; Gersh, Bernard J; Kowey, Peter R; Mahaffey, Kenneth W; Hylek, Elaine; Go, Alan S; Thomas, Laine; Peterson, Eric D; Piccini, Jonathan P
2018-04-13
Mineralocorticoid receptor antagonist (MRA) therapy may be beneficial to patients with atrial fibrillation (AF), but little is known about their use in patients with AF and subsequent outcomes. In order to better understand MRA use and subsequent outcomes, we performed a retrospective cohort study of the contemporary ORBIT-AF (Outcomes Registry for Better Informed Treatment of Atrial Fibrillation) registry. AF progression and cardiovascular outcomes were compared using propensity-matched Cox proportional hazards modeling according to MRA use at baseline and new MRA use at follow-up versus patients with no MRA use. Among 7012 patients with nonpermanent AF, 320 patients were taking MRA at enrollment, and 416 patients initiated MRA use during follow-up. The mean patient age was 72.5 years, 56.3% were men, and 70.4% had paroxysmal AF. Among all patients taking MRAs, 434 (59.0%) had heart failure, 655 (89.0%) had hypertension, and 380 (51.6%) had both. After adjustment, new MRA use was not associated with reduced AF progression (hazard ratio, 1.18; 95% confidence interval, 0.88-1.58; P =0.27) but showed a trend towards lower risk of stroke, transient ischemic attack, or systemic embolism (hazard ratio, 0.17; 95% confidence interval, 0.02-1.23; P =0.08). Results were similar for a comparison of new MRA users and baseline MRA users compared with nonusers. In community-based outpatients with AF, the majority of MRA use was for heart failure and hypertension. MRA use also trended towards lower adjusted stroke risk. Future studies should test the hypothesis that MRA use may decrease the risk of stroke in patients with AF. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Robust edge states in amorphous gyromagnetic photonic lattices
NASA Astrophysics Data System (ADS)
Mansha, Shampy; Chong, Y. D.
2017-09-01
We numerically study amorphous analogs of a two-dimensional photonic Chern insulator. The amorphous lattices consist of gyromagnetic rods that break time-reversal symmetry, with the lattice sites generated by a close-packing algorithm. The level of short-range order is adjustable, and there is no long-range order. The topologically nontrivial gaps of the photonic Chern insulator are found to persist into the amorphous regime, so long as there is sufficient short-range order. Strongly nonreciprocal robust transmission occurs via edge states, which are shown to propagate ballistically despite the absence of long-range order, and to be exponentially localized along the lattice edge. Interestingly, there is an enhancement of nonreciprocal transmission even at very low levels of short-range order, where there are no discernible spectral gaps.
Structural and magnetic aspects of La4(Co1-xNix)3O10+δ (0 ≤ x ≤ 1)
NASA Astrophysics Data System (ADS)
Nagell, Marius Uv; Kumar, Susmit; Sørby, Magnus H.; Fjellvåg, Helmer; Olafsen Sjåstad, Anja
2015-10-01
The Ruddlesden-Popper (RP3) type oxides, La4Co3O10+δ and La4Ni3O10+δ, form a complete solid solution. Powder X-ray and neutron diffraction data show that La4(Co1-xNix)3O10+δ is isostructural to the monoclinic La4Co3O10+δ structure (P21/a) described for all compositions without any further structural distortions as suggested in the literature. A slight elongation of the Co/Ni-O bonds facing the rock salt interlayer occurs for Ni-rich compositions. The magnetic properties of the solid solution series are mapped in the temperature range from 4 to 300 K, and the results are presented in a magnetic phase diagram. Three regimes with antiferromagnetic order (AF) exist at low temperatures, TN < 10 - 30 K. For x = 0.00, the AF is ascribed to Co(II), whereas a broader AF regime around x = 0.50 is ascribed mainly to Ni(II). Pauli paramagnetism is observed close to metallic La4Ni3O10+δ, x > 0.80. The possibility to tune the oxidation state of the transition metal atoms is demonstrated for La4Co3O10+δ, and exemplified by weakening of a temperature-induced spin transition at around 480 K.
NASA Astrophysics Data System (ADS)
Huang, B. Y.; Lu, Z. X.; Zhang, Y.; Xie, Y. L.; Zeng, M.; Yan, Z. B.; Liu, J.-M.
2016-05-01
The polarization-electric field hysteresis loops and the dynamics of polarization switching in a two-dimensional antiferroelectric (AFE) lattice submitted to a time-oscillating electric field E(t) of frequency f and amplitude E0, is investigated using Monte Carlo simulation based on the Landau-Devonshire phenomenological theory on antiferroelectrics. It is revealed that the AFE double-loop hysteresis area A, i.e., the energy loss in one cycle of polarization switching, exhibits the single-peak frequency dispersion A(f), suggesting the unique characteristic time for polarization switching, which is independent of E0 as long as E0 is larger than the quasi-static coercive field for the antiferroelectric-ferroelectric transitions. However, the dependence of recoverable stored energy W on amplitude E0 seems to be complicated depending on temperature T and frequency f. A dynamic scaling behavior of the energy loss dispersion A(f) over a wide range of E0 is obtained, confirming the unique characteristic time for polarization switching of an AFE lattice. The present simulation may shed light on the dynamics of energy storage and release in AFE thin films.
Application of Traditional Chinese Medicine in Treatment of Atrial Fibrillation
Dong, Yan; Yao, Kuiwu; Jiang, Wenrui
2017-01-01
Atrial fibrillation (AF) is the most common cardiac arrhythmia, which is related to many cardiac and cerebral vascular diseases, especially stroke. It can therefore increase cardiovascular mortality and all-cause death. The current treatments of AF remain to be western drugs and radiofrequency ablation which are limited by the tolerance of patients, adverse side effects, and high recurrence rate, especially for the elderly. On the contrary, traditional Chinese medicine (TCM) with long history of use involves various treatment methods, including Chinese herbal medicines (CHMs) or bioactive ingredients, Chinese patent medicines, acupuncture, Qigong, and Tai Chi Chuan. With more and more researches reported, the active roles of TCM in AF management have been discovered. Then it is likely that TCM would be effective preventive means and valuable additional remedy for AF. The potential mechanisms further found by numerous experimental studies showed the distinct characteristics of TCM. Some CHMs or bioactive ingredients are atrial-selective, while others are multichannel and multifunctional. Therefore, in this review we summarized the treatment strategies reported in TCM, with the purpose of providing novel ideas and directions for AF management. PMID:28243308
Left atrial appendage closure: a new technique for clinical practice.
John Camm, A; Colombo, Antonio; Corbucci, Giorgio; Padeletti, Luigi
2014-03-01
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. It is associated with increased risk for stroke mainly due to cardiac embolism from the left atrial appendage (LAA). Occlusion of the LAA by means of a device represents a valid alternative to oral anticoagulation, mainly in patients who cannot tolerate this therapy because of a high bleeding risk. Recent data on the endocardial device WATCHMAN show encouraging results for this patient population in terms of stroke risk reduction compared to the expected rate as well as in terms of implant success. This article reviews all relevant publications related to the main surgical and transcatheter devices used for LAA closure (LAAC). PROTECT-AF, the first prospective randomized trial conducted on this technique, showed that LAA occlusion using the WATCHMAN was noninferior to warfarin for a combined end-point in patients with nonvalvular AF. There is a lack of large-scale randomized trials on long-term stroke risk in patients submitted to LAAC. Most studies are relatively small and focus on the comparison of different surgical techniques with regard to complete/incomplete closure success. More recently, PROTECT-AF long-term results (4-year follow-up) demonstrated that LAAC was statistically superior to warfarin in terms of efficacy. This review concludes that it is now appropriate to consider these techniques for patients with AF who are at high risk for stroke for whom effective conventional or novel anticoagulant therapy is not available or who present problems in managing drug treatment. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Thinking outside the Box: Rotor Modulation in the Treatment of Atrial Fibrillation.
Sehra, Ruchir; Narayan, Sanjiv M; Hummel, John
2013-01-01
Ablation for atrial fibrillation (AF) is an important and exciting therapy whose results remain suboptimal. Although most clinical trials show that ablation eliminates AF more effectively than medications, it is disappointing that the continued single procedural success remains ≈50% despite the substantial advances that have taken place in imaging, catheter positioning and energy delivery. Focal impulse and rotor modulation (FIRM), on the other hand, offers the opportunity to precisely define and then ablate patient-specific sustaining mechanisms for AF, rather than trying to eliminate all possible AF triggers. For over a decade, electrophysiologists have described cases in which AF terminates after only limited ablation - usually that cannot be explained by 'random' meandering wavelets. Indeed, recent studies from several laboratories show that all forms of clinical AF are typically 'driven' by stable electrical rotors and focal sources, not by multiple meandering waves. FIRM mapping enables an operator to place a catheter at typically 1-3 predicted sites in the atria, and with <5-10 minutes of RF ablation, terminate AF and potentially render it non-inducible. Several independent laboratories have now shown that such FIRM ablation alone can terminate or substantially slow AF in >80% of patients with persistent and paroxysmal AF and increase the single procedure rate of AF elimination from 50% with PV isolation alone to >80%. Ongoing studies hint that FIRM only ablation, enabling ablation times in the range observed for typical atrial flutter, may also achieve these high success rates without subsequent trigger ablation. This review summarizes the current state-of-the-art on FIRM mapping and ablation.
Pelissero, Elisa; Giuggia, Marco; Todaro, Maria Chiara; Trapani, Giuseppe; Giordano, Benedetta; Senatore, Gaetano
2017-12-01
We evaluated long-term safety and efficacy of concomitant left atrial appendage (LAA) closure and atrial fibrillation (AF) ablation. From February 2013 to June 2017, all patients referred for AF ablation and LAA closure (group 1) were enrolled in the study and compared with a matched control group undergoing AF ablation only (group 2). Pulmonary vein isolation was achieved in all cases with radiofrequency or cryoballoon. LAA was occluded with Watchman or Amplatzer Cardiac Plug or Amulet (ACP) devices. All patients were treated with oral anticoagulation therapy for at least 3 months after the procedure ("blanking period"), and then switched to dual antiplatelet therapy with aspirin and clopidogrel for other 3 months, and then to single antiplatelet therapy with aspirin in case of LAA closure, while group 2 was treated with long-term oral anticoagulation therapy according to CHA2DS2-VASc score. Follow-up was performed with transesophageal echocardiography and clinical visit at 3, 6 and 12 months after the procedure. AF burden was evaluated by loop recorder or pacemaker interrogation in all patients. Overall, 42 patients were enrolled, 21 in each group. Mean age was 66.86 ± 10.35 years in group 1 vs 68.42 ± 10.61 in group 2 (p=NS); mean CHA2DS2-VASc score was 2.8 ± 1.22 in group 1 vs 2.01 ± 0.93 in group 2 (p=NS), mean HAS-BLED score was 3.2 ± 0.83 in group 1 vs 3.1 ± 0.95 in group 2 (p=NS). Persistent AF was present in 80% of patients in group 1 and in 85% in group 2. LAA closure was successful in all cases (14 Watchman, 7 ACP devices). Procedural and fluoroscopy times were shorter in group 2 (68 ± 17 vs 52 ± 15 min, p <0.05; 23 ± 5 vs 18 ± 3 min, p <0.05, respectively). No procedural complications were observed in group 2, while in group 1 one case of self-terminating pericardial effusion and one arteriovenous fistula were observed. At a mean follow-up of 14.93 ± 10.05 months, complete seal of LAA was documented in all patients, with neither dislocations nor thromboembolic events. Similarly, no long-term complications were observed in group 2. Maintenance of sinus rhythm was overlapping, with an AF relapse rate of 36% in group 1 vs 38% in group 2 (p=NS). Combined LAA percutaneous closure and AF ablation appears to be feasible in high-risk patients.
Biomaterials in the Treatment of Anal Fistula: Hope or Hype?
Scoglio, Daniele; Walker, Avery S.; Fichera, Alessandro
2014-01-01
Anal fistula (AF) presents a chronic problem for patients and colorectal surgeons alike. Surgical treatment may result in impairment of continence and long-term risk of recurrence. Treatment options for AFs vary according to their location and complexity. The ideal approach should result in low recurrence rates and minimal impact on continence. New technical approaches involving biologically derived products such as biological mesh, fibrin glue, fistula plug, and stem cells have been applied in the treatment of AF to improve outcomes and decrease recurrence rates and the risk of fecal incontinence. In this review, we will highlight the current evidence and describe our personal experience with these novel approaches. PMID:25435826
Face-selective neurons maintain consistent visual responses across months
McMahon, David B. T.; Jones, Adam P.; Bondar, Igor V.; Leopold, David A.
2014-01-01
Face perception in both humans and monkeys is thought to depend on neurons clustered in discrete, specialized brain regions. Because primates are frequently called upon to recognize and remember new individuals, the neuronal representation of faces in the brain might be expected to change over time. The functional properties of neurons in behaving animals are typically assessed over time periods ranging from minutes to hours, which amounts to a snapshot compared to a lifespan of a neuron. It therefore remains unclear how neuronal properties observed on a given day predict that same neuron's activity months or years later. Here we show that the macaque inferotemporal cortex contains face-selective cells that show virtually no change in their patterns of visual responses over time periods as long as one year. Using chronically implanted microwire electrodes guided by functional MRI targeting, we obtained distinct profiles of selectivity for face and nonface stimuli that served as fingerprints for individual neurons in the anterior fundus (AF) face patch within the superior temporal sulcus. Longitudinal tracking over a series of daily recording sessions revealed that face-selective neurons maintain consistent visual response profiles across months-long time spans despite the influence of ongoing daily experience. We propose that neurons in the AF face patch are specialized for aspects of face perception that demand stability as opposed to plasticity. PMID:24799679
Face-selective neurons maintain consistent visual responses across months.
McMahon, David B T; Jones, Adam P; Bondar, Igor V; Leopold, David A
2014-06-03
Face perception in both humans and monkeys is thought to depend on neurons clustered in discrete, specialized brain regions. Because primates are frequently called upon to recognize and remember new individuals, the neuronal representation of faces in the brain might be expected to change over time. The functional properties of neurons in behaving animals are typically assessed over time periods ranging from minutes to hours, which amounts to a snapshot compared to a lifespan of a neuron. It therefore remains unclear how neuronal properties observed on a given day predict that same neuron's activity months or years later. Here we show that the macaque inferotemporal cortex contains face-selective cells that show virtually no change in their patterns of visual responses over time periods as long as one year. Using chronically implanted microwire electrodes guided by functional MRI targeting, we obtained distinct profiles of selectivity for face and nonface stimuli that served as fingerprints for individual neurons in the anterior fundus (AF) face patch within the superior temporal sulcus. Longitudinal tracking over a series of daily recording sessions revealed that face-selective neurons maintain consistent visual response profiles across months-long time spans despite the influence of ongoing daily experience. We propose that neurons in the AF face patch are specialized for aspects of face perception that demand stability as opposed to plasticity.
Piekarski, Eve; Chitiboi, Teodora; Ramb, Rebecca; Feng, Li; Axel, Leon
2016-11-25
Arrhythmia can significantly alter the image quality of cardiovascular magnetic resonance (CMR); automatic detection and sorting of the most frequent types of arrhythmias during the CMR acquisition could potentially improve image quality. New CMR techniques, such as non-Cartesian CMR, can allow self-gating: from cardiac motion-related signal changes, we can detect cardiac cycles without an electrocardiogram. We can further use this data to obtain a surrogate for RR intervals (valley intervals: VV). Our purpose was to evaluate the feasibility of an automated method for classification of non-arrhythmic (NA) (regular cycles) and arrhythmic patients (A) (irregular cycles), and for sorting of common arrhythmia patterns between atrial fibrillation (AF) and premature ventricular contraction (PVC), using the cardiac motion-related signal obtained during self-gated free-breathing radial cardiac cine CMR with compressed sensing reconstruction (XD-GRASP). One hundred eleven patients underwent cardiac XD-GRASP CMR between October 2015 and February 2016; 33 were included for retrospective analysis with the proposed method (6 AF, 8 PVC, 19 NA; by recent ECG). We analyzed the VV, using pooled statistics (histograms) and sequential analysis (Poincaré plots), including the median (medVV), the weighted mean (meanVV), the total number of VV values (VVval), and the total range (VVTR) and half range (VVHR) of the cumulative frequency distribution of VV, including the median to half range (medVV/VVHR) and the half range to total range (VVHR/VVTR) ratios. We designed a simple algorithm for using the VV results to differentiate A from NA, and AF from PVC. Between NA and A, meanVV, VVval, VVTR, VVHR, medVV/VVHR and VVHR/VVTR ratios were significantly different (p values = 0.00014, 0.0027, 0.000028, 5×10 -9 , 0.002, respectively). Between AF and PVC, meanVV, VVval and medVV/VVHR ratio were significantly different (p values = 0.018, 0.007, 0.044, respectively). Using our algorithm, sensitivity, specificity, and accuracy were 93 %, 95 % and 94 % to discriminate between NA and A, and 83 %, 71 %, and 77 % to discriminate between AF and PVC, respectively; areas under the ROC curve were 0.93 and 0.89. Our study shows we can reliably detect arrhythmias and differentiate AF from PVC, using self-gated cardiac cine XD-GRASP CMR.
Sanie-Jahromi, Fatemeh; Ahmadieh, Hamid; Soheili, Zahra-Soheila; Davari, Maliheh; Ghaderi, Shima; Kanavi, Mozhgan Rezaei; Samiei, Shahram; Deezagi, Abdolkhalegh; Pakravesh, Jalil; Bagheri, Abouzar
2012-04-10
Retinal progenitor cells are a convenient source of cell replacement therapy in retinal degenerative disorders. The purpose of this study was to evaluate the expression patterns of the homeobox genes PAX6 and CHX10 (retinal progenitor markers) during treatment of human retinal pigment epithelium (RPE) cells with amniotic fluid (AF), RPE cells harvested from neonatal cadaver globes were cultured in a mixture of DMEM and Ham's F12 supplemented with 10% FBS. At different passages, cells were trypsinized and co-cultured with 30% AF obtained from normal fetuses of 1416 weeks gestational age. Compared to FBS-treated controls, AF-treated cultures exhibited special morphological changes in culture, including appearance of spheroid colonies, improved initial cell adhesion and ordered cell alignment. Cell proliferation assays indicated a remarkable increase in the proliferation rate of RPE cells cultivated in 30% AF-supplemented medium, compared with those grown in the absence of AF. Immunocytochemical analyses exhibited nuclear localization of retinal progenitor markers at a ratio of 33% and 27% for CHX10 and PAX6, respectively. This indicated a 3-fold increase in retinal progenitor markers in AF-treated cultures compared to FBS-treated controls. Real-time PCR data of retinal progenitor genes (PAX6, CHX10 and VSX-1) confirmed these results and demonstrated AF's capacity for promoting retinal progenitor cell generation. Taken together, the results suggest that AF significantly promotes the rate of retinal progenitor cell generation, indicating that AF can be used as an enriched supplement for serum-free media used for the in vitro propagation of human progenitor cells.
Both Hypothyroidism and Hyperthyroidism Increase Atrial Fibrillation Inducibility in Rats
Zhang, Youhua; Dedkov, Eduard I.; Teplitsky, Diana; Weltman, Nathan Y.; Pol, Christine J.; Rajagopalan, Viswanathan; Lee, Bianca; Gerdes, A. Martin
2014-01-01
Background Evidence indicates that cardiac hypothyroidism may contribute to heart failure (HF) progression. It is also known that HF is associated with an increased risk of atrial fibrillation (AF). While it is established that hyperthyroidism increases AF incidence, the effect of hypothyroidism on AF is unclear. This study investigated the effects of different thyroid hormone levels, ranging from hypothyroidism to hyperthyroidism on AF inducibility in thyroidectomized rats. Methods and Results Thyroidectomized rats with serum confirmed hypothyroidism 1 month after surgery were randomized into hypothyroid (n=9), euthyroid (n=9) and hyperthyroid (n=9) groups. Rats received placebo, 3.3mg L-thyroxine (T4), or 20 mg T4 pellets (60 day release form) for 2 months, respectively. At the end of treatment, hypothyroid, euthyroid and hyperthyroid status was confirmed. Hypothyroid animals showed cardiac atrophy and reduced cardiac systolic and diastolic function, while hyperthyroid rats exhibited cardiac hypertrophy and increased cardiac function. Hypothyroidism and hyperthyroidism produced opposite electrophysiological changes in heart rates and atrial effective refractory period, but both significantly increased AF susceptibility. AF incidence was 78% in hypothyroid, 67% in hyperthyroid, and the duration of induced AF was also longer, compared with 11% in the euthyroid group (all p<0.05). Hypothyroidism increased atrial interstitial fibrosis, but connexin 43 was not affected. Conclusions Both hypothyroidism and hyperthyroidism lead to increased AF vulnerability in a rat thyroidectomy model. Our results stress that normal thyroid hormone levels are required to maintain normal cardiac electrophysiology and prevent cardiac arrhythmias and AF. PMID:24036190
Both hypothyroidism and hyperthyroidism increase atrial fibrillation inducibility in rats.
Zhang, Youhua; Dedkov, Eduard I; Teplitsky, Diana; Weltman, Nathan Y; Pol, Christine J; Rajagopalan, Viswanathan; Lee, Bianca; Gerdes, A Martin
2013-10-01
Evidence indicates that cardiac hypothyroidism may contribute to heart failure progression. It is also known that heart failure is associated with an increased risk of atrial fibrillation (AF). Although it is established that hyperthyroidism increases AF incidence, the effect of hypothyroidism on AF is unclear. This study investigated the effects of different thyroid hormone levels, ranging from hypothyroidism to hyperthyroidism on AF inducibility in thyroidectomized rats. Thyroidectomized rats with serum-confirmed hypothyroidism 1 month after surgery were randomized into hypothyroid (N=9), euthyroid (N=9), and hyperthyroid (N=9) groups. Rats received placebo, 3.3-mg l-thyroxine (T4), or 20-mg T4 pellets (60-day release form) for 2 months, respectively. At the end of treatment, hypothyroid, euthyroid, and hyperthyroid status was confirmed. Hypothyroid animals showed cardiac atrophy and reduced cardiac systolic and diastolic functions, whereas hyperthyroid rats exhibited cardiac hypertrophy and increased cardiac function. Hypothyroidism and hyperthyroidism produced opposite electrophysiological changes in heart rates and atrial effective refractory period, but both significantly increased AF susceptibility. AF incidence was 78% in hypothyroid, 67% in hyperthyroid, and the duration of induced AF was also longer, compared with 11% in the euthyroid group (all P<0.05). Hypothyroidism increased atrial interstitial fibrosis, but connexin 43 was not affected. Both hypothyroidism and hyperthyroidism lead to increased AF vulnerability in a rat thyroidectomy model. Our results stress that normal thyroid hormone levels are required to maintain normal cardiac electrophysiology and to prevent cardiac arrhythmias and AF.
Potpara, Tatjana S; Dan, Gheorghe-Andrei; Trendafilova, Elina; Goda, Artan; Kusljugic, Zumreta; Manola, Sime; Music, Ljilja; Musetescu, Rodica; Badila, Elisabeta; Mitic, Gorana; Paparisto, Vilma; Dimitrova, Elena S; Polovina, Marija M; Petranov, Stanislav L; Djergo, Hortensia; Loncar, Daniela; Bijedic, Amira; Brusich, Sandro; Lip, Gregory Y H
2016-02-12
Data on the management of atrial fibrillation (AF) in the Balkan Region are limited. The Serbian AF Association (SAFA) prospectively investigated contemporary 'real-world' AF management in clinical practice in Albania, Bosnia&Herzegovina, Bulgaria, Croatia, Montenegro, Romania and Serbia through a 14-week (December 2014-February 2015) prospective, multicentre survey of consecutive AF patients. We report the results pertinent to stroke prevention strategies. Of 2712 enrolled patients, 2663 (98.2%) with complete data were included in this analysis (mean age 69.1 ± 10.9 years, female 44.6%). Overall, 1960 patients (73.6%) received oral anticoagulants (OAC) and 762 (28.6%) received antiplatelet drugs. Of patients given OAC, 17.2% received non-vitamin K antagonist oral anticoagulants (NOACs). CHA2DS2-VASc score was not significantly associated with OAC use. Of the 'truly low-risk' patients (CHA2DS2-VASc = 0 [males], or 1 [females]) 56.5% received OAC. Time in Therapeutic Range (TTR) was available in only 18.7% of patients (mean TTR: 49.5% ± 22.3%). Age ≥ 80 years, prior myocardial infarction and paroxysmal AF were independent predictors of OAC non-use. Our survey shows a relatively high overall use of OAC in AF patients, but with low quality of vitamin K antagonist therapy and insufficient adherence to AF guidelines. Additional efforts are needed to improve AF-related thromboprophylaxis in clinical practice in the Balkan Region.
Lazar, Sorin; Dixit, Sanjay; Callans, David J; Lin, David; Marchlinski, Francis E; Gerstenfeld, Edward P
2006-08-01
We previously demonstrated the existence of a left-to-right atrial dominant frequency gradient during paroxysmal but not persistent atrial fibrillation (AF) in humans. One possible mechanism of the left-to-right dominant frequency gradient involves the role of the pulmonary veins (PVs) in AF maintenance. The purpose of this study was to examine the effect of PV isolation on the dominant frequency gradient and outcome after PV isolation. Patients with either paroxysmal or persistent AF were studied. Recordings were made from catheters in the coronary sinus (CS), posterior right atrium (RA), and posterior left atrium (LA) during AF before and after PV isolation. Mean left-to-right dominant frequency gradient was measured before and after segmental PV isolation. Patients were followed for AF recurrence after PV isolation. Twenty-seven patients with paroxysmal (n = 15) or persistent (n = 12) AF were studied. In the paroxysmal group, baseline dominant frequency was greatest in the posterior LA with a significant left-to-right atrial dominant frequency gradient (posterior LA = 6.2 +/- 0.9 Hz, CS = 5.8 +/- 0.8 Hz, posterior RA = 5.4 +/- 0.9 Hz; P <.001). After PV isolation, there was no regional difference in dominant frequency (5.9 +/- 0.7 Hz vs 5.7 +/- 0.6 Hz vs 5.7 +/- 0.7 Hz, respectively; P = NS). In the persistent AF group, there was no overall difference in dominant frequency among sites before or after PV isolation (P = NS); however, patients with long-term freedom from AF after PV isolation had a higher left-to-right dominant frequency gradient compared with patients with recurrent AF (0.4 vs 0.1 Hz; P <.05). PV isolation results in a loss in the left-to-right dominant frequency gradient in patients with paroxysmal AF. This finding supports the critical role of PVs in the maintenance of ongoing paroxysmal AF. Patients with persistent AF and a baseline left-to-right dominant frequency gradient have a better success rate with PV isolation alone compared with patients without a dominant frequency gradient.
Retrospective Evaluation of the Effect of Heart Rate on Survival in Dogs with Atrial Fibrillation.
Pedro, B; Dukes-McEwan, J; Oyama, M A; Kraus, M S; Gelzer, A R
2018-01-01
Atrial fibrillation (AF) usually is associated with a rapid ventricular rate. The optimal heart rate (HR) during AF is unknown. Heart rate affects survival in dogs with chronic AF. Forty-six dogs with AF and 24-hour ambulatory recordings were evaluated. Retrospective study. Holter-derived HR variables were analyzed as follows: mean HR (meanHR, 24-hour average), minimum HR (minHR, 1-minute average), maximum HR (maxHR, 1-minute average). Survival times were recorded from the time of presumed adequate rate control. The primary endpoint was all-cause mortality. Cox proportional hazards analysis identified variables independently associated with survival; Kaplan-Meier survival analysis estimated the median survival time of dogs with meanHR <125 bpm versus ≥125 bpm. All 46 dogs had structural heart disease; 31 of 46 had congestive heart failure (CHF), 44 of 46 received antiarrhythmic drugs. Of 15 dogs with cardiac death, 14 had CHF. Median time to all-cause death was 524 days (Interquartile range (IQR), 76-1,037 days). MeanHR was 125 bpm (range, 62-203 bpm), minHR was 82 bpm (range, 37-163 bpm), maxHR was 217 bpm (range, 126-307 bpm). These were significantly correlated with all-cause and cardiac-related mortality. For every 10 bpm increase in meanHR, the risk of all-cause mortality increased by 35% (hazard ratio, 1.35; 95% CI, 1.17-1.55; P < 0.001). Median survival time of dogs with meanHR<125 bpm (n = 23) was significantly longer (1,037 days; range, 524-open) than meanHR ≥125 bpm (n = 23; 105 days; range, 67-267 days; P = 0.0012). Mean HR was independently associated with all-cause and cardiovascular mortality (P < 0.003). Holter-derived meanHR affects survival in dogs with AF. Dogs with meanHR <125 bpm lived longer than those with meanHR ≥ 125 bpm. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Ramírez-Prada, Jonathan; Robledo, Sara M; Vélez, Iván D; Crespo, María Del Pilar; Quiroga, Jairo; Abonia, Rodrigo; Montoya, Alba; Svetaz, Laura; Zacchino, Susana; Insuasty, Braulio
2017-05-05
A new series of N-substituted 2-pyrazolines 9a-f, 10a-f, 11a-f, 12a-f and 13a-f were obtained from the cyclocondensation reaction of [(7-chloroquinolin-4-yl)amino]chalcones 8a-f with hydrazine hydrate and its derivatives. Fourteen of the synthesized compounds including the starting chalcones were selected by US National Cancer Institute (NCI) for testing their anticancer activity against 60 different human cancer cell lines, with the most important GI 50 values ranging from 0.28 to 11.7 μM (0.13-6.05 μg/mL) and LC 50 values ranging from 2.6 to > 100 μM (1.2 to > 51.7 μg/mL), for chalcones 8a,d and pyrazolines 10c,d. All compounds were assessed for antibacterial activity against wild type and multidrug resistant gram negative and gram positive bacteria, with MIC values ranging from 31.25 to 500 μg/mL. Additionally, the novel compounds were tested for antifungal and antiparasitic properties. Although these compounds showed mild activity against Candida albicans, chalcones 8a and 8e showed high activity against Cryptococcus neoformans with MIC 50 = 7.8 μg/mL. For anti-Plasmodium falciparum activity the 2-pyrazoline 11b was the most active with EC 50 = 5.54 μg/mL. Regarding the activity against Trypanosoma cruzi, compound 10a was highly active with EC 50 = 0.70 μg/mL. Chalcone 8a had good activity against Leishmania panamensis amastigotes with EC 50 = 0.79 μg/mL. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Ma, Haiyan; Ran, Congcong; Li, Mengjiao; Gao, Jinglin; Wang, Xinyu; Zhang, Lina; Bian, Jing; Li, Junmei; Jiang, Ye
2018-04-01
Mycotoxins are potential food pollutants produced by fungi. Among them, aflatoxins (AFs) are the most toxic. Therefore, AFs were selected as models, and a sensitive, simple and green graphene oxide (GO)-based stir bar sorptive extraction (SBSE) method was developed for extraction and determination of AFs with high performance liquid chromatography-laser-induced fluorescence detector (HPLC-LIF). This method improved the sensitivity of AFs detection and solved the deposition difficulty of the direct use of GO as adsorbent. Several parameters including a spiked amount of NaCl, stirring rate, extraction time and desorption time were investigated. Under optimal conditions, the quantitative method had low limits of detection of 2.4-8.0 pg/mL, which were better than some reported AFs analytical methods. The developed method has been applied to soy milk samples with good recoveries ranging from 80.5 to 102.3%. The prepared GO-based SBSE can be used as a sensitive screening technique for detecting AFs in soy milk.
Dronedarone: a promising alternative for the management of atrial fibrillation.
Yalta, Kenan; Turgut, Okan Onur; Yilmaz, Mehmet Birhan; Yilmaz, Ahmet; Tandogan, Izzet
2009-10-01
Atrial fibrillation (AF) is the most frequently encountered chronic arrhythmia associated with significant morbidity. It is generally encountered in the elderly, and will presumably become more prevalent in the future due to the increasing proportion of the elderly in the population. Major studies on AF have demonstrated no significant difference between rhythm and rate control in terms of mortality. However, young population with new-onset or lone AF, or patients in whom the maintenance of sinus rhythm is a must (due to recurrent thromboembolic events etc.) still gives rise to significant concerns related to the obligatory long-term prophylaxis. The long-term administration of the currently available conventional agents (amiodarone, dofetilide, sotalol, propafenone,flecainide etc.) is considered as a 'double edged sword' due to the presence of life-threatening adverse effects including pro-arrhythmia and organ toxicity associated with these agents. Several molecules are being developed for the management of AF. However, only a few novel agents confer promising results with respect to safety and efficacy issues in the major studies. Dronedarone is an amiodarone analogue without iodine moiety in its structure, and is similar to amiodarone with regard to its structural and electrophysiological properties. Dronedarone is largely denuded of the potentially life-threatening adverse effects of anti-arrhythmics. Major clinical studies have demonstrated both rhythm and rate-controlling efficacy of dronedarone compared to placebo without any serious adverse effects in patients with AF. However, the ANDROMEDA trial, a large scale study including patients hospitalized for symptomatic congestive heart failure (with severely depressed left ventricular systolic functions) was prematurely terminated due to the increased mortality in the dronedarone arm compared to placebo indicating a lack of safety in this group of patients. Conversely, the recently published ATHENA study (including more than 4,600 high risk patients, but excluding those with severe heart failure) demonstrated a significant reduction in cardiovascular hospitalizations and cardiovascular mortality with dronedarone compared to placebo. In contrast, the DIONYSOS study, comparing dronedarone with amiodarone, demonstrated better safety, but lower efficacy of dronedarone for the maintenance of sinus rhythm in patients with AF. Further clinical trials (including head to head comparison with other conventional anti-arrhythmics) are still required to determine the place of dronedarone in the management of AF. The present review focuses on basic and clinical aspects of dronedarone, a novel agent for the management of AF.
Simon, Jillian N; Ziberna, Klemen; Casadei, Barbara
2016-04-01
Although the initiation, development, and maintenance of atrial fibrillation (AF) have been linked to alterations in myocyte redox state, the field lacks a complete understanding of the impact these changes may have on cellular signalling, atrial electrophysiology, and disease progression. Recent studies demonstrate spatiotemporal changes in reactive oxygen species production shortly after the induction of AF in animal models with an uncoupling of nitric oxide synthase activity ensuing in the presence of long-standing persistent AF, ultimately leading to a major shift in nitroso-redox balance. However, it remains unclear which radical or non-radical species are primarily involved in the underlying mechanisms of AF or which proteins are targeted for redox modification. In most instances, only free radical oxygen species have been assessed; yet evidence from the redox signalling field suggests that non-radical species are more likely to regulate cellular processes. A wider appreciation for the distinction of these species and how both species may be involved in the development and maintenance of AF could impact treatment strategies. In this review, we summarize how redox second-messenger systems are regulated and discuss the recent evidence for alterations in redox regulation in the atrial myocardium in the presence of AF, while identifying some critical missing links. We also examine studies looking at antioxidants for the prevention and treatment of AF and propose alternative redox targets that may serve as superior therapeutic options for the treatment of AF. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology.
Global-scale high-resolution ( 1 km) modelling of mean, maximum and minimum annual streamflow
NASA Astrophysics Data System (ADS)
Barbarossa, Valerio; Huijbregts, Mark; Hendriks, Jan; Beusen, Arthur; Clavreul, Julie; King, Henry; Schipper, Aafke
2017-04-01
Quantifying mean, maximum and minimum annual flow (AF) of rivers at ungauged sites is essential for a number of applications, including assessments of global water supply, ecosystem integrity and water footprints. AF metrics can be quantified with spatially explicit process-based models, which might be overly time-consuming and data-intensive for this purpose, or with empirical regression models that predict AF metrics based on climate and catchment characteristics. Yet, so far, regression models have mostly been developed at a regional scale and the extent to which they can be extrapolated to other regions is not known. We developed global-scale regression models that quantify mean, maximum and minimum AF as function of catchment area and catchment-averaged slope, elevation, and mean, maximum and minimum annual precipitation and air temperature. We then used these models to obtain global 30 arc-seconds (˜ 1 km) maps of mean, maximum and minimum AF for each year from 1960 through 2015, based on a newly developed hydrologically conditioned digital elevation model. We calibrated our regression models based on observations of discharge and catchment characteristics from about 4,000 catchments worldwide, ranging from 100 to 106 km2 in size, and validated them against independent measurements as well as the output of a number of process-based global hydrological models (GHMs). The variance explained by our regression models ranged up to 90% and the performance of the models compared well with the performance of existing GHMs. Yet, our AF maps provide a level of spatial detail that cannot yet be achieved by current GHMs.
Extracting uranium from seawater: Promising AF series adsorbents
Das, Sadananda; Oyola, Y.; Mayes, Richard T.; ...
2015-11-02
Here, a new family of high surface area polyethylene fiber adsorbents (AF series) was recently developed at the Oak Ridge National Laboratory (ORNL). The AF series of were synthesized by radiation-induced graft polymerization of acrylonitrile and itaconic acid (at different monomer/co-monomer mol ratios) onto high surface area polyethylene fibers. The degree of grafting (%DOG) of AF series adsorbents was found to be 154 354%. The grafted nitrile groups were converted to amidoxime groups by treating with hydroxylamine. The amidoximated adsorbents were then conditioned with 0.44M KOH at 80 C followed by screening at ORNL with simulated seawater spiked with 8more » ppm uranium. Uranium adsorption capacity in simulated seawater screening ranged from 170-200 g-U/kg-ads irrespective of %DOG. A monomer/co-monomer mol ratio in the range of 7.57-10.14 seemed to be optimum for highest uranium loading capacity. Subsequently, the adsorbents were also tested with natural seawater at Pacific Northwest National Laboratory (PNNL) using flow-through exposure uptake experiments to determine uranium loading capacity with varying KOH conditioning time at 80 C. The highest adsorption capacity of AF1 measured after 56 days of marine testing was demonstrated as 3.9 g-U/kg-adsorbent and 3.2 g-U/kg-adsorbent for 1hr and 3hrs of KOH conditioning at 80 C, respectively. Based on capacity values of several AF1 samples, it was observed that changing KOH conditioning from 3hrs to 1hr at 80 C resulted in 22-27% increase in uranium loading capacity in seawater.« less
Extracting uranium from seawater: Promising AF series adsorbents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Das, Sadananda; Oyola, Y.; Mayes, Richard T.
Here, a new family of high surface area polyethylene fiber adsorbents (AF series) was recently developed at the Oak Ridge National Laboratory (ORNL). The AF series of were synthesized by radiation-induced graft polymerization of acrylonitrile and itaconic acid (at different monomer/co-monomer mol ratios) onto high surface area polyethylene fibers. The degree of grafting (%DOG) of AF series adsorbents was found to be 154 354%. The grafted nitrile groups were converted to amidoxime groups by treating with hydroxylamine. The amidoximated adsorbents were then conditioned with 0.44M KOH at 80 C followed by screening at ORNL with simulated seawater spiked with 8more » ppm uranium. Uranium adsorption capacity in simulated seawater screening ranged from 170-200 g-U/kg-ads irrespective of %DOG. A monomer/co-monomer mol ratio in the range of 7.57-10.14 seemed to be optimum for highest uranium loading capacity. Subsequently, the adsorbents were also tested with natural seawater at Pacific Northwest National Laboratory (PNNL) using flow-through exposure uptake experiments to determine uranium loading capacity with varying KOH conditioning time at 80 C. The highest adsorption capacity of AF1 measured after 56 days of marine testing was demonstrated as 3.9 g-U/kg-adsorbent and 3.2 g-U/kg-adsorbent for 1hr and 3hrs of KOH conditioning at 80 C, respectively. Based on capacity values of several AF1 samples, it was observed that changing KOH conditioning from 3hrs to 1hr at 80 C resulted in 22-27% increase in uranium loading capacity in seawater.« less
Tanigawa, Takahiko; Kaneko, Masato; Hashizume, Kensei; Kajikawa, Mariko; Ueda, Hitoshi; Tajiri, Masahiro; Paolini, John F; Mueck, Wolfgang
2013-01-01
The global ROCKET AF phase III trial evaluated rivaroxaban 20 mg once daily (o.d.) for stroke prevention in atrial fibrillation (AF). Based on rivaroxaban pharmacokinetics in Japanese subjects and lower anticoagulation preferences in Japan, particularly in elderly patients, the optimal dose regimen for Japanese AF patients was considered. The aim of this analysis was dose selection for Japanese patients from a pharmacokinetic aspect by comparison of simulated exposure in Japanese patients with those in Caucasian patients. As a result of population pharmacokinetics-pharmacodynamics analyses, a one-compartment pharmacokinetic model with first-order absorption and direct link pharmacokinetic-pharmacodynamic models optimally described the plasma concentration and pharmacodynamic models (Factor Xa activity, prothrombin time, activated partial thromboplastin time, and HepTest), which were also consistent with previous works. Steady-state simulations indicated 15 mg rivaroxaban o.d. doses in Japanese patients with AF would yield exposures comparable to the 20 mg o.d. dose in Caucasian patients with AF. In conclusion, in the context of the lower anticoagulation targets in Japanese practice, the population pharmacokinetic and pharmacodynamic modeling supports 15 mg o.d. as the principal rivaroxaban dose in J-ROCKET AF.
Johnson, Samuel G
2009-08-01
The medical care costs for procedures, medications, and testing associated with atrial fibrillation (AF) in the United States are high and projected to increase markedly in the future as the number of Americans affected grows. The burden on patient quality of life, the health care system, and society are pharmacoeconomic considerations in managing AF. To identify key pharmacoeconomic considerations in managing AF and describe ways in which managed care pharmacists can improve the cost-effectiveness of and outcomes from drug therapy for AF. The high medical care costs of AF are largely the result of the high cost of hospitalization and inpatient procedures. Recurrence of AF dramatically increases costs, especially for hospital care. Managed care pharmacists have many opportunities to provide cost-effective care to and improve outcomes in patients with AF. Policy and process review, population management, and case management are key strategies for improving outcomes in patients with AF. Pharmacist input into policy and process review, including pharmacy benefits design, formulary management, and the use of information technology, can help ensure that the use of drug therapy for AF is cost-effective. Population management strategies, such as development of clinical pathways and patient registries, seek to improve the quality, consistency, and cost-effectiveness of care and the likelihood that desired therapeutic outcomes are achieved through targeted interventions. Case management strategies focus on longitudinal care for individuals in order to improve quality. Pharmacist-managed anticoagulation services and antiarrhythmic drug monitoring are the 2 most widely known case management strategies for patients with AF. Managed care pharmacists can screen patients with AF for the use of anticoagulation, which is needed to prevent embolic stroke but is under-used, even though recommended by evidence-based guidelines. The clinical efficacy and cost-effectiveness of pharmacist-managed anticoagulation services for patients with AF are well documented. Pharmacist-managed antiarrhythmic drug monitoring is a less well-known case management strategy that facilitates early detection and intervention to minimize toxicity. Managed care pharmacists can play an instrumental role in implementing strategies to improve the cost-effectiveness of and outcomes from drug therapy for AF.
Anderson, Debra F.; Cheung, Cecilia Y.
2014-01-01
Experimentation in late-gestation fetal sheep has suggested that regulation of amniotic fluid (AF) volume occurs primarily by modulating the rate of intramembranous transport of water and solutes across the amnion into underlying fetal blood vessels. In order to gain insight into intramembranous transport mechanisms, we developed a computer model that allows simulation of experimentally measured changes in AF volume and composition over time. The model included fetal urine excretion and lung liquid secretion as inflows into the amniotic compartment plus fetal swallowing and intramembranous absorption as outflows. By using experimental flows and solute concentrations for urine, lung liquid, and swallowed fluid in combination with the passive and active transport mechanisms of the intramembranous pathway, we simulated AF responses to basal conditions, intra-amniotic fluid infusions, fetal intravascular infusions, urine replacement, and tracheoesophageal occlusion. The experimental data are consistent with four intramembranous transport mechanisms acting in concert: 1) an active unidirectional bulk transport of AF with all dissolved solutes out of AF into fetal blood presumably by vesicles; 2) passive bidirectional diffusion of solutes, such as sodium and chloride, between fetal blood and AF; 3) passive bidirectional water movement between AF and fetal blood; and 4) unidirectional transport of lactate into the AF. Further, only unidirectional bulk transport is dynamically regulated. The simulations also identified areas for future study: 1) identifying intramembranous stimulators and inhibitors, 2) determining the semipermeability characteristics of the intramembranous pathway, and 3) characterizing the vesicles that are the primary mediators of intramembranous transport. PMID:25186112
Salinet, João L; Masca, Nicholas; Stafford, Peter J; Ng, G André; Schlindwein, Fernando S
2016-03-08
Areas with high frequency activity within the atrium are thought to be 'drivers' of the rhythm in patients with atrial fibrillation (AF) and ablation of these areas seems to be an effective therapy in eliminating DF gradient and restoring sinus rhythm. Clinical groups have applied the traditional FFT-based approach to generate the three-dimensional dominant frequency (3D DF) maps during electrophysiology (EP) procedures but literature is restricted on using alternative spectral estimation techniques that can have a better frequency resolution that FFT-based spectral estimation. Autoregressive (AR) model-based spectral estimation techniques, with emphasis on selection of appropriate sampling rate and AR model order, were implemented to generate high-density 3D DF maps of atrial electrograms (AEGs) in persistent atrial fibrillation (persAF). For each patient, 2048 simultaneous AEGs were recorded for 20.478 s-long segments in the left atrium (LA) and exported for analysis, together with their anatomical locations. After the DFs were identified using AR-based spectral estimation, they were colour coded to produce sequential 3D DF maps. These maps were systematically compared with maps found using the Fourier-based approach. 3D DF maps can be obtained using AR-based spectral estimation after AEGs downsampling (DS) and the resulting maps are very similar to those obtained using FFT-based spectral estimation (mean 90.23 %). There were no significant differences between AR techniques (p = 0.62). The processing time for AR-based approach was considerably shorter (from 5.44 to 5.05 s) when lower sampling frequencies and model order values were used. Higher levels of DS presented higher rates of DF agreement (sampling frequency of 37.5 Hz). We have demonstrated the feasibility of using AR spectral estimation methods for producing 3D DF maps and characterised their differences to the maps produced using the FFT technique, offering an alternative approach for 3D DF computation in human persAF studies.
NASA Astrophysics Data System (ADS)
Jia, Yue; Chopdekar, Rajesh V.; Shafer, Padraic; Arenholz, Elke; Liu, Zhiqi; Biegalski, Michael D.; Takamura, Yayoi
2017-12-01
The magnetic structure of exchange-coupled antiferromagnetic (AF) layers in epitaxial L a0.7S r0.3Mn O3 (LSMO)/L a0.7S r0.3Fe O3 (LSFO) superlattices grown on (111)-oriented SrTi O3 substrates was studied using angle-dependent x-ray absorption spectroscopy utilizing linearly polarized x rays. We demonstrate the development of the measurement protocols needed to determine the orientation of the LSFO antiferromagnetic spin axis and how it responds to an applied magnetic field due to exchange interactions with an adjacent ferromagnetic layer. A small energy difference exists between two types of AF order: the majority of the AF moments cant out-of-the-plane of the film along the 110 or 100 directions depending on the LSFO layer thickness. In response to an applied magnetic field, these canted moments are aligned with a single 110 or 100 direction that maintains a nearly perpendicular orientation relative to the LSMO sublayer magnetization. The remaining AF moments lie within the (111 ) plane and these in-plane moments can be reoriented to an arbitrary in-plane direction to lie parallel to the LSMO sublayer magnetization. These results demonstrate that the magnetic order of AF thin films and heterostructures is far more complex than in bulk LSFO and can be tuned with orientation, thickness, and applied magnetic field.
Aronis, Konstantinos N; Zhao, Di; Hoogeveen, Ron C; Alonso, Alvaro; Ballantyne, Christie M; Guallar, Eliseo; Jones, Steven R; Martin, Seth S; Nazarian, Saman; Steffen, Brian T; Virani, Salim S; Michos, Erin D
2017-12-15
Lipoprotein(a) (Lp[a]) is proatherosclerotic and prothrombotic, causally related to coronary disease, and associated with other cardiovascular diseases. The association of Lp(a) with incident atrial fibrillation (AF) and with ischemic stroke among individuals with AF remains to be elucidated. In the community-based ARIC (Atherosclerosis Risk in Communities) study cohort, Lp(a) levels were measured by a Denka Seiken assay at visit 4 (1996-1998). We used multivariable-adjusted Cox models to compare AF and ischemic stroke risk across Lp(a) levels. First, we evaluated incident AF in 9908 participants free of AF at baseline. AF was ascertained by electrocardiography at study visits, hospital International Statistical Classification of Diseases, 9th Revision ( ICD-9 ) codes, and death certificates. We then evaluated incident ischemic stroke in 10 127 participants free of stroke at baseline. Stroke was identified by annual phone calls, hospital ICD-9 Revision codes, and death certificates. The baseline age was 62.7±5.6 years. Median Lp(a) levels were 13.3 mg/dL (interquartile range, 5.2-39.7 mg/dL). Median follow-up was 13.9 and 15.8 years for AF and stroke, respectively. Lp(a) was not associated with incident AF (hazard ratio, 0.98; 95% confidence interval, 0.82-1.17), comparing those with Lp(a) ≥50 with those with Lp(a) <10 mg/dL. High Lp(a) was associated with a 42% relative increase in stroke risk among participants without AF (hazard ratio, 1.42; 95% confidence interval, 1.07-1.90) but not in those with AF (hazard ratio, 1.06; 95% confidence interval, 0.70-1.61 [ P interaction for AF=0.25]). There were no interactions by race or sex. No association was found for cardioembolic stroke subtype. High Lp(a) levels were not associated with incident AF. Lp(a) levels were associated with increased ischemic stroke risk, primarily among individuals without AF but not in those with AF. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
McLellan, Alex J A; Prabhu, Sandeep; Voskoboinik, Alex; Wong, Michael C G; Walters, Tomos E; Pathik, Bhupesh; Morris, Gwilym M; Nisbet, Ashley; Lee, Geoffrey; Morton, Joseph B; Kalman, Jonathan M; Kistler, Peter M
2017-12-01
Catheter ablation to achieve posterior left atrial wall (PW) isolation may be performed as an adjunct to pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (AF). We aimed to determine whether routine adenosine challenge for dormant posterior wall conduction improved long-term outcome. A total of 161 patients with persistent AF (mean age 59 ± 9 years, AF duration 6 ± 5 years) underwent catheter ablation involving circumferential PVI followed by PW isolation. Posterior left atrial wall isolation was performed with a roof and inferior wall line with the endpoint of bidirectional block. In 54 patients, adenosine 15 mg was sequentially administered to assess reconnection of the pulmonary veins and PW. Sites of transient reconnection were ablated and adenosine was repeated until no further reconnection was present. Holter monitoring was performed at 6 and 12 months to assess for arrhythmia recurrence. Posterior left atrial wall isolation was successfully achieved in 91% of 161 patients (procedure duration 191 ± 49 min, mean RF time 40 ± 19 min). Adenosine-induced reconnection of the PW was demonstrated in 17%. The single procedure freedom from recurrent atrial arrhythmia was superior in the adenosine challenge group (65%) vs. no adenosine challenge (40%, P < 0.01) at a mean follow-up of 19 ± 8 months. After multiple procedures, there was significantly improved freedom from AF between patients with vs. without adenosine PW challenge (85 vs. 65%, P = 0.01). Posterior left atrial wall isolation in addition to PVI is a readily achievable ablation strategy in patients with persistent AF. Routine adenosine challenge for dormant posterior wall conduction was associated with an improvement in the success of catheter ablation for persistent AF. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions please email: journals.permissions@oup.com.
Automated paleomagnetic and rock magnetic data acquisition with an in-line horizontal "2G" system
NASA Astrophysics Data System (ADS)
Mullender, Tom A. T.; Frederichs, Thomas; Hilgenfeldt, Christian; de Groot, Lennart V.; Fabian, Karl; Dekkers, Mark J.
2016-09-01
Today's paleomagnetic and magnetic proxy studies involve processing of large sample collections while simultaneously demanding high quality data and high reproducibility. Here we describe a fully automated interface based on a commercial horizontal pass-through "2G" DC-SQUID magnetometer. This system is operational at the universities of Bremen (Germany) and Utrecht (Netherlands) since 1998 and 2006, respectively, while a system is currently being built at NGU Trondheim (Norway). The magnetometers are equipped with "in-line" alternating field (AF) demagnetization, a direct-current bias field coil along the coaxial AF demagnetization coil for the acquisition of anhysteretic remanent magnetization (ARM) and a long pulse-field coil for the acquisition of isothermal remanent magnetization (IRM). Samples are contained in dedicated low magnetization perspex holders that are manipulated by a pneumatic pick-and-place-unit. Upon desire samples can be measured in several positions considerably enhancing data quality in particular for magnetically weak samples. In the Bremen system, the peak of the IRM pulse fields is actively measured which reduces the discrepancy between the set field and the field that is actually applied. Techniques for quantifying and removing gyroremanent overprints and for measuring the viscosity of IRM further extend the range of applications of the system. Typically c. 300 paleomagnetic samples can be AF demagnetized per week (15 levels) in the three-position protocol. The versatility of the system is illustrated by several examples of paleomagnetic and rock magnetic data processing.
Direct writing of birefringent elements by ultrafast laser nanostructuring in multicomponent glass
NASA Astrophysics Data System (ADS)
Fedotov, S. S.; Drevinskas, R.; Lotarev, S. V.; Lipatiev, A. S.; Beresna, M.; ČerkauskaitÄ--, A.; Sigaev, V. N.; Kazansky, P. G.
2016-02-01
Self-assembled nanostructures created by femtosecond laser irradiation are demonstrated in alkali-free aluminoborosilicate glass. The growth of the induced retardance associated with the nanograting formation is three orders of magnitude slower than in silica glass and is observed only within a narrow range of pulse energies. However, the strength of retardance asymptotically approaches the value typically measured in pure silica glass, which is attractive for practical applications. A similar intensity threshold for nanograting formation of about 1 TW/cm2 is observed for all glasses studied. The radially polarized vortex beam micro-converter designed as a space-variant quarter-wave retarder for the near-infrared spectral range is imprinted in commercial Schott AF32 glass.
Spin Dynamics in the electron-doped high-Tc superconductors Pr0.88LaCe0.12CuO4-δ
NASA Astrophysics Data System (ADS)
Dai, Pengcheng
2007-03-01
We briefly review results of recent neutron scattering experiments designed to probe the evolution of antiferromagnetic (AF) order and spin dynamics in the electron- doped Pr0.88LaCe0.12CuO4-δ (PLCCO) as the system is tuned from its as-grown non-superconducting AF state into an optimally doped superconductor (Tc = 27.5 K) without static AF order [1-3]. For under doped materials, a quasi-two- dimensional spin-density wave was found to coexist with three- dimensional AF order and superconductivity. In addition, the low-energy spin excitations follow Bose statistics. In the case of optimally doped material, we have discovered a magnetic resonance intimately related to superconductivity analogous to the resonance in hole-doped materials. On the other hand, the low energy spin excitations have very weak temperature dependence and do not follow Bose statistics, in sharp contrast to the as-grown nonsuperconducting materials. 1 Stephen D. Wilson, Pengcheng Dai, Shiliang Li, Songxue Chi, H. J. Kang, and J. W. Lynn, Nature (London) 442, 59 (2006). 2 Stephen D. Wilson, Shiliang Li, Hyungje Woo, Pengcheng Dai, H. A. Mook, C. D. Frost, S. Komiya, and Y. Ando, Phys. Rev. Lett. 96, 157001 (2006). 3. Stephen D. Wilson, Shiliang Li, Pengcheng Dai, Wei Bao, J. H. Chung, H. J. Kang, S.-H. Lee, S. Komiya, and Y. Ando, Phys. Rev. B 74, 144514 (2006).
Majeed, Saima; Iqbal, Mazhar; Asi, Muhammad Rafique; Iqbal, Shahzad Zafar; Selamat, Jinap
2017-12-01
Recently, cultivation of high-yielding hybrid maize varieties has revolutionized maize production in Pakistan. Analyses of nutritional traits and aflatoxin (AF) contamination in these varieties can aid in the identification of susceptible and resistant varieties, particularly for cultivation in the Pakistani agro-climatic environment. Five spring maize varieties-Pioneer, Neelam, DK-919, Desi, and Hi-maize-were selected for analyses of their nutritional, tocopherol, and AF contents. Protein, carbohydrate, oil, ash, fiber, and moisture contents ranged between 8.7 and 10.8%, 68 and 71%, 3.72 and 5.56%, 1.09 and 1.81%, 1.1 and 3.1%, and 11.7 and 14.2%, respectively. Tocopherol levels in selected varieties were in the range of 461 to 1,430 μg/g. Hi-maize exhibited significantly higher protein and tocopherol contents than the other varieties, indicating its better suitability for feed and silage applications. The highest mean level of total AFs, 14.5 ± 0.12 μg/kg, was found in Desi, and results showed that the most dominant AF found in the maize varieties was AFB 1 . Furthermore, the results showed that the higher the level of tocopherol, the lower the concentration of total AFs and vice versa in maize varieties. The results can be used to investigate additional susceptible maize varieties that are resistant to fungal attack.
Liżewska-Springer, Aleksandra; Dąbrowska-Kugacka, Alicja; Lewicka, Ewa; Drelich, Łukasz; Królak, Tomasz; Raczak, Grzegorz
2018-06-20
Catheter ablation (CA) is a well-known treatment option for patients with symptomatic drug-resistant atrial fibrillation (AF). Multiple factors have been identified to determine AF recurrence after CA, however their predictive value is rather small. Identification of novel predictors of CA outcome is therefore of primary importance to reduce health costs and improve long-term results of this intervention. The recurrence of AF following CA is related to the severity of left ventricular (LV) dysfunction, extend of atrial dilatation and fibrosis. The aim of this paper was to present and discuss the latest studies on utility of echocardiographic parameters in terms of CA effectiveness in patients with paroxysmal and persistent AF. PubMed, Google Scholar, EBSCO databases were searched for studies reporting echocardiographic preprocedural predictors of AF recurrence after CA. LV systolic and diastolic function, as well as atrial size, strain and dyssynchrony were taken into consideration. Twenty one full-text articles were analyzed, including three meta-analyses. Several echocardiographic parameters have been reported to determine a risk of AF recurrence after CA. There are conventional methods that measure left atrial (LA) size and volume, LV ejection fraction, parameters assessing LV diastolic dysfunction, and methods using more innovative technologies based on speckle tracking echocardiography (STE) to determine LA synchrony and strain. Each of these parameters has its own predictive value. Regarding CA effectiveness, every patient has to be evaluated individually to estimate the risk of AF recurrence, optimally using a combination of several echocardiographic parameters.
Mina, Adel; Warnecke, Nicholas
2015-01-01
The objective of this study was to evaluate the long term efficacy and safety of the atrial fibrillation program at Unity Point Health Methodist in Peoria. A retrospective analysis was performed on patients who had atrial fibrillation procedures at Unity Point Methodist from February 19 th 2010 to September 26 th 2014. Patients were enrolled and information obtained through the patient's medical records. The study consisted of 53 patients, 65 percent of patients were paroxysmal, and 35 percent had chronic or persistent atrial fibrillation. The mean age was 66 +/- 23 (45 to 89 years). The average CHADS-Vasc Score is score is 2.13. Baseline co-morbidities included 34 individuals with HTN, 10 with Diabetes, and 4 with coronary artery disease. The average EF was 55% +/-25 (30% to 70%) and the average LA diameter 41 +/-15 mm (25-56). The average number of antiarrhythmic was 1.5 prior to ablation. After a mean follow-up of 28 ± 29 months (range, 3 to 57 months), freedom from AF was 94% overall (51 of 53 patients, including 52 were on antiarrhythmic drugs), 94% for paroxysmal AF (34 of 36 patients, including 24 of whom discontinued their antiarrhythmic drugs), and 94% for persistent AF (16 of 17 patients, including 9 no longer on antiarrhythmic drugs). 76 percent experienced a decrease in their antiarrhythmic medications of which 60 percent discontinued antiarrhythmic altogether. Out of the 53 patients, there were three major but completely reversible transient complications. Two of the complications were related to pericardial effusion that was successfully drained with no recurrence. The last complication was phrenic nerve injury in a patient who showed complete recovery 4 month after the procedure. Long-term results of atrial fibrillation ablation at Unity Point Health Methodist showed safety and efficacy of the program in the treatment of symptomatic atrial fibrillation in both paroxysmal and persistent groups.
Risk Factors For Bradycardia Requiring Pacemaker Implantation In Patients With Atrial Fibrillation
Barrett, Tyler W.; Abraham, Robert L.; Jenkins, Cathy A.; Russ, Stephan; Storrow, Alan B.; Darbar, Dawood
2012-01-01
Symptomatic bradycardia may complicate atrial fibrillation (AF) and necessitate a permanent pacemaker. Identifying patients at increased risk for symptomatic bradycardia may reduce associated morbidities and healthcare costs. We investigated predictors for developing bradycardia requiring a permanent pacemaker among AF patients. We reviewed records of all patients treated for AF/flutter in an academic hospital’s emergency department from 8/1/2005 to 8/30/2008. We determined survival and presence of a pacemaker as of 11/1/2011. Cases were defined as patients with pacemakers placed for bradycardia after their AF diagnoses. Patients without a pacemaker who were followed at our hospital comprised the controls. We identified a priori variables for the logistic regression analysis. We fit a post-hoc model adjusting for AF type and atrioventricular nodal blocker (AVN) use. Of the 362 patients in our cohort, 119 cases had permanent pacemakers implanted for bradycardia subsequent to AF diagnosis and 243 controls were alive without a pacemaker. Median and interquartile range follow-up time was 4.5 (3.8 – 5.4) years. Odds ratios and 95% confidence intervals were determined for age at time of AF diagnosis (1.02 [1, 1.04]), female (1.58 [0.95, 2.63]), prior heart failure (2.72 [1.47, 5.01]), and African-American (0.33 [0.12, 0.94]). Post-hoc model identified permanent AF (2.99 [1.61, 5.57]) and AVN use (1.43 [0.85, 2.4]). In conclusion, among AF patients, heart failure and permanent AF each nearly triple the odds of developing bradycardia requiring a permanent pacemaker; while not statistically significant, our results suggest that women are more likely and African-Americans less likely to develop bradycardia requiring pacemaker implantation. PMID:22840846
Cone Photoreceptor Abnormalities Correlate with Vision Loss in Patients with Stargardt Disease
Chen, Yingming; Ratnam, Kavitha; Sundquist, Sanna M.; Lujan, Brandon; Ayyagari, Radha; Gudiseva, V. Harini; Roorda, Austin
2011-01-01
Purpose. To study the relationship between macular cone structure, fundus autofluorescence (AF), and visual function in patients with Stargardt disease (STGD). Methods. High-resolution images of the macula were obtained with adaptive optics scanning laser ophthalmoscopy (AOSLO) and spectral domain optical coherence tomography in 12 patients with STGD and 27 age-matched healthy subjects. Measures of retinal structure and AF were correlated with visual function, including best-corrected visual acuity, color vision, kinetic and static perimetry, fundus-guided microperimetry, and full-field electroretinography. Mutation analysis of the ABCA4 gene was completed in all patients. Results. Patients were 15 to 55 years old, and visual acuity ranged from 20/25–20/320. Central scotomas were present in all patients, although the fovea was spared in three patients. The earliest cone spacing abnormalities were observed in regions of homogeneous AF, normal visual function, and normal outer retinal structure. Outer retinal structure and AF were most normal near the optic disc. Longitudinal studies showed progressive increases in AF followed by reduced AF associated with losses of visual sensitivity, outer retinal layers, and cones. At least one disease-causing mutation in the ABCA4 gene was identified in 11 of 12 patients studied; 1 of 12 patients showed no disease-causing ABCA4 mutations. Conclusions. AOSLO imaging demonstrated abnormal cone spacing in regions of abnormal fundus AF and reduced visual function. These findings provide support for a model of disease progression in which lipofuscin accumulation results in homogeneously increased AF with cone spacing abnormalities, followed by heterogeneously increased AF with cone loss, then reduced AF with cone and RPE cell death. (ClinicalTrials.gov number, NCT00254605.) PMID:21296825
The cost savings of newer oral anticoagulants in atrial fibrillation-related stroke prevention .
Masbah, Norliana; Macleod, Mary Joan
2017-03-01
Newer oral anticoagulants (NOACs) are considered as better alternatives compared to warfarin for stroke prevention in atrial fibrillation (AF) in terms of clinical effectiveness although the drug acquisition cost is more substantial. This study determined the direct stroke costs based on inpatient hospitalization in a subgroup of the National Health Service (NHS) Grampian, Scotland, stroke patients, to evaluate the differences in costs related to AF stroke, and to ascertain whether the use of NOACs within this study population would produce greater cost savings. Hospitalization records over 5 years involving 3,601 stroke patients were analyzed. Direct costs were based on the costs of inpatient length of stay per day. The potential cost savings if AF patients had been on NOACs were estimated using efficacy data from a landmark clinical trial involving rivaroxaban. Out of the total stroke cases, 29.5% of total stroke cases were secondary to AF, and these cases were more severe with longer hospitalizations. Only 254 patients (39.4%) with confirmed AF were anticoagulated with warfarin prior to admission. AF patients incurred higher median costs (£4,719 (interquartile range (IQR) £1,815 - £12,452) compared to non-AF patients (£3,267 (IQR £1,175 - £11,368)), although the association was statistically insignificant. The use of NOACs in AF-related patients with ischemic strokes would potentially prevent more strokes (leading to 58 fewer cases in comparison to warfarin), resulting in 17.1% in total cost reduction. AF stroke patients incurred higher total direct costs compared to non-AF cases. However, more cost savings were evident with NOACs, due to more strokes being prevented through the use of NOACs compared to warfarin. .
Balbi, Carolina; Piccoli, Martina; Barile, Lucio; Papait, Andrea; Armirotti, Andrea; Principi, Elisa; Reverberi, Daniele; Pascucci, Luisa; Becherini, Pamela; Varesio, Luigi; Mogni, Massimo; Coviello, Domenico; Bandiera, Tiziano; Pozzobon, Michela; Cancedda, Ranieri; Bollini, Sveva
2017-05-01
Human amniotic fluid stem cells (hAFS) have shown a distinct secretory profile and significant regenerative potential in several preclinical models of disease. Nevertheless, little is known about the detailed characterization of their secretome. Herein we show for the first time that hAFS actively release extracellular vesicles (EV) endowed with significant paracrine potential and regenerative effect. c-KIT + hAFS were isolated from leftover samples of amniotic fluid from prenatal screening and stimulated to enhance EV release (24 hours 20% O 2 versus 1% O 2 preconditioning). The capacity of the c-KIT + hAFS-derived EV (hAFS-EV) to induce proliferation, survival, immunomodulation, and angiogenesis were investigated in vitro and in vivo. The hAFS-EV regenerative potential was also assessed in a model of skeletal muscle atrophy (HSA-Cre, Smn F7/F7 mice), in which mouse AFS transplantation was previously shown to enhance muscle strength and survival. hAFS secreted EV ranged from 50 up to 1,000 nm in size. In vitro analysis defined their role as biological mediators of regenerative, paracrine effects while their modulatory role in decreasing skeletal muscle inflammation in vivo was shown for the first time. Hypoxic preconditioning significantly induced the enrichment of exosomes endowed with regenerative microRNAs within the hAFS-EV. In conclusion, this is the first study showing that c-KIT + hAFS dynamically release EV endowed with remarkable paracrine potential, thus representing an appealing tool for future regenerative therapy. Stem Cells Translational Medicine 2017;6:1340-1355. © 2017 The Authors Stem Cells Translational Medicine published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.
NASA Astrophysics Data System (ADS)
Murakami, Yuta; Werner, Philipp; Tsuji, Naoto; Aoki, Hideo
2013-09-01
We study the Holstein-Hubbard model at half filling to explore ordered phases including superconductivity (SC), antiferromagnetism (AF), and charge order (CO) in situations where the electron-electron and electron-phonon interactions are strong (comparable to the electronic bandwidth). The model is solved in the dynamical mean-field approximation with a continuous-time quantum Monte Carlo impurity solver. We determine the superconducting transition temperature Tc and the SC order parameter and show that the phonon-induced retardation or the strong Coulomb interaction leads to a significant reduction and shift of the Tc dome against the effective electron-electron interaction Ueff given by the Hubbard U reduced by the phonon-mediated attraction in the static limit. This behavior is analyzed by comparison to an effective static model in the polaron representation with a renormalized bandwidth. In addition, we discuss the superconducting gap Δ and 2Δ/Tc to reveal the effect of the retardation and the Coulomb interaction. We also determine the finite-temperature phase diagram including AF and CO. In the moderate-coupling regime, there is a hysteretic region of AF and CO around Ueff=0, while the two phases are separated by a paramagnetic metal in the weak-coupling regime and a paramagnetic insulator in the strong-coupling regime.
Differential baroreflex control of heart rate in sedentary and aerobically fit individuals
NASA Technical Reports Server (NTRS)
Smith, S. A.; Querry, R. G.; Fadel, P. J.; Welch-O'Connor, R. M.; Olivencia-Yurvati, A.; Shi, X.; Raven, P. B.
2000-01-01
PURPOSE: We compared arterial, aortic, and carotid-cardiac baroreflex sensitivity in eight average fit (maximal oxygen uptake, VO2max = 42.2+/-1.9 mL x kg(-1) x min(-1)) and eight high fit (VO2max = 61.9+/-2.2 mL x kg(-1) x min(-1)) healthy young adults. METHODS: Arterial and aortic (ABR) baroreflex functions were assessed utilizing hypo- and hyper-tensive challenges induced by graded bolus injections of sodium nitroprusside (SN) and phenylephrine (PE), respectively. Carotid baroreflex (CBR) sensitivity was determined using ramped 5-s pulses of both pressure and suction delivered to the carotid sinus via a neck chamber collar, independent of drug administration. RESULTS: During vasoactive drug injection, mean arterial pressure (MAP) was similarly altered in average fit (AF) and high fit (HF) groups. However, the heart rate (HR) response range of the arterial baroreflex was significantly attenuated (P < 0.05) in HF (31+/-4 beats x min(-1)) compared with AF individuals (46+/-4 beats x min(-1)). When sustained neck suction and pressure were applied to counteract altered carotid sinus pressure during SN and PE administration, isolating the ABR response, the response range remained diminished (P < 0.05) in the HF population (24+/-3 beats x min(-1)) compared with the AF group (41+/-4 beats x min(-1)). During CBR perturbation, the HF (14+/-1 beats-min(-1)) and AF (16+/-1 beats-min(-1)) response ranges were similar. The arterial baroreflex response range was significantly less than the simple sum of the CBR and ABR (HF, 38+/-3 beats x min(-1) and AF, 57+/-4 beats x min(-1)) in both fitness groups. CONCLUSIONS: These data confirm that reductions in arterial-cardiac reflex sensitivity are mediated by diminished ABR function. More importantly, these data suggest that the integrative relationship between the ABR and CBR contributing to arterial baroreflex control of HR is inhibitory in nature and not altered by exercise training.
Singer, Daniel E; Hellkamp, Anne S; Yuan, Zhong; Lokhnygina, Yuliya; Patel, Manesh R; Piccini, Jonathan P; Hankey, Graeme J; Breithardt, Günter; Halperin, Jonathan L; Becker, Richard C; Hacke, Werner; Nessel, Christopher C; Mahaffey, Kenneth W; Fox, Keith A A; Califf, Robert M
2015-03-03
In the ROCKET AF (Rivaroxaban-Once-daily, oral, direct Factor Xa inhibition Compared with vitamin K antagonism for prevention of stroke and Embolism Trial in Atrial Fibrillation) trial, marked regional differences in control of warfarin anticoagulation, measured as the average individual patient time in the therapeutic range (iTTR) of the international normalized ratio (INR), were associated with longer inter-INR test intervals. The standard Rosendaal approach can produce biased low estimates of TTR after an appropriate dose change if the follow-up INR test interval is prolonged. We explored the effect of alternative calculations of TTR that more immediately account for dose changes on regional differences in mean iTTR in the ROCKET AF trial. We used an INR imputation method that accounts for dose change. We compared group mean iTTR values between our dose change-based method with the standard Rosendaal method and determined that the differences between approaches depended on the balance of dose changes that produced in-range INRs ("corrections") versus INRs that were out of range in the opposite direction ("overshoots"). In ROCKET AF, the overall mean iTTR of 55.2% (Rosendaal) increased up to 3.1% by using the dose change-based approach, depending on assumptions. However, large inter-regional differences in anticoagulation control persisted. TTR, the standard measure of control of warfarin anticoagulation, depends on imputing daily INR values for the vast majority of follow-up days. Our TTR calculation method may better reflect the impact of warfarin dose changes than the Rosendaal approach. In the ROCKET AF trial, this dose change-based approach led to a modest increase in overall mean iTTR but did not materially affect the large inter-regional differences previously reported. URL: ClinicalTrials.gov. Unique identifier: NCT00403767. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Singer, Daniel E.; Hellkamp, Anne S.; Yuan, Zhong; Lokhnygina, Yuliya; Patel, Manesh R.; Piccini, Jonathan P.; Hankey, Graeme J.; Breithardt, Günter; Halperin, Jonathan L.; Becker, Richard C.; Hacke, Werner; Nessel, Christopher C.; Mahaffey, Kenneth W.; Fox, Keith A. A.; Califf, Robert M.
2015-01-01
Background In the ROCKET AF (Rivaroxaban–Once‐daily, oral, direct Factor Xa inhibition Compared with vitamin K antagonism for prevention of stroke and Embolism Trial in Atrial Fibrillation) trial, marked regional differences in control of warfarin anticoagulation, measured as the average individual patient time in the therapeutic range (iTTR) of the international normalized ratio (INR), were associated with longer inter‐INR test intervals. The standard Rosendaal approach can produce biased low estimates of TTR after an appropriate dose change if the follow‐up INR test interval is prolonged. We explored the effect of alternative calculations of TTR that more immediately account for dose changes on regional differences in mean iTTR in the ROCKET AF trial. Methods and Results We used an INR imputation method that accounts for dose change. We compared group mean iTTR values between our dose change–based method with the standard Rosendaal method and determined that the differences between approaches depended on the balance of dose changes that produced in‐range INRs (“corrections”) versus INRs that were out of range in the opposite direction (“overshoots”). In ROCKET AF, the overall mean iTTR of 55.2% (Rosendaal) increased up to 3.1% by using the dose change–based approach, depending on assumptions. However, large inter‐regional differences in anticoagulation control persisted. Conclusions TTR, the standard measure of control of warfarin anticoagulation, depends on imputing daily INR values for the vast majority of follow‐up days. Our TTR calculation method may better reflect the impact of warfarin dose changes than the Rosendaal approach. In the ROCKET AF trial, this dose change–based approach led to a modest increase in overall mean iTTR but did not materially affect the large inter‐regional differences previously reported. Clinical Trial Registration URL: ClinicalTrials.gov. Unique identifier: NCT00403767. PMID:25736441
Williams, Brent A; Evans, Michael A; Honushefsky, Ashley M; Berger, Peter B
2017-10-12
Though warfarin has historically been the primary oral anticoagulant for stroke prevention in newly diagnosed atrial fibrillation (AF), several new direct oral anticoagulants may be preferred when anticoagulation control with warfarin is expected to be poor. This study developed a prediction model for time in therapeutic range (TTR) among newly diagnosed AF patients on newly initiated warfarin as a tool to assist decision making between warfarin and direct oral anticoagulants. This electronic medical record-based, retrospective study included newly diagnosed, nonvalvular AF patients with no recent warfarin exposure receiving primary care services through a large healthcare system in rural Pennsylvania. TTR was estimated as the percentage of time international normalized ratio measurements were between 2.0 and 3.0 during the first year following warfarin initiation. Candidate predictors of TTR were chosen from data elements collected during usual clinical care. A TTR prediction model was developed and temporally validated and its predictive performance was compared with the SAMe-TT 2 R 2 score (sex, age, medical history, treatment, tobacco, race) using R 2 and c-statistics. A total of 7877 newly diagnosed AF patients met study inclusion criteria. Median (interquartile range) TTR within the first year of starting warfarin was 51% (32, 67). Of 85 candidate predictors evaluated, 15 were included in the final validated model with an R 2 of 15.4%. The proposed model showed better predictive performance than the SAMe-TT 2 R 2 score ( R 2 =3.0%). The proposed prediction model may assist decision making on the proper mode of oral anticoagulant among newly diagnosed AF patients. However, predicting TTR on warfarin remains challenging. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
den Dulk, K; Dijkman, B; Pieterse, M; Wellens, H
1994-11-01
Mode switching algorithms have been developed to avoid tracking of atrial fibrillation (AF) or flutter (AFL) during DDD(R) pacing. Upon recognition of AF or AFL, the mode is switched to a nontracking, sensor driven mode. The Vitatron Diamond model 800 pacemaker does this on a beat-to-beat basis. Atrial events occurring within a "physiological range" (+/- 15 beats/min) calculated from a running average of the atrial rate are tracked. When atrial events are not tracked the escape interval is either determined by the sensor(s) or by a fallback algorithm thereby preventing large increases in V-V interval during mode switching. Loss of atrioventricular (AV) synchrony by atrial premature beats and after an episode of AF or AFL is prevented by atrial synchronization pulses (ASP), which are delivered after a safe interval (timed out from the sensed premature atrial event) has expired and before delivery of the next ventricular stimulus. We implanted 26 such devices in 18 men and 8 women with symptomatic second- or third-degree AV block and paroxysmal AF or AFL. Their ages ranged from 18-84 years (mean 60), and the follow-up ranged from 2-13 months (mean 8). During pacemaker check-up, exercise testing or 24-hour Holter monitoring one or more episodes of mode switching was documented in 8 patients. In these 8 patients a smooth transition (ventricular rate) from sinus rhythm to AF or AFL was documented on one or more occasions, without inappropriate increase in ventricular rate in the DDDR mode. None of the patients complained of palpitations.(ABSTRACT TRUNCATED AT 250 WORDS)
Li, Jing-Jie; Wei, Fang; Chen, Ju-Gang; Yu, Yan-Wei; Gu, Hong-Yue; Jiang, Rui; Wu, Xiu-Li; Sun, Qian
2014-01-01
Purpose The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE). Methods All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls. Results Results showed significant differences in both body mass index (BMI) and supraventricular tachycardia (SVT) duration between WPW patients and DAVNP patients (both P<0.05). Echocardiography revealed that the maximum left atrial volume (LAVmax) and the left ventricular mass index (LVMI) in diastole increased noticeably in patients with WPW compared to patients with DAVNP both before and after ablation (all P<0.05). Before ablation, there were obvious differences in the levels of SRs, SRe, and SRa from the 4-chamber view (LA) in the WPW patients group compared with patients in the DAVNP group (all P<0.05). In the AF group, there were significant differences in the levels of systolic strain rate (SRs), early diastolic strain rate (SRe), and late diastolic strain rate (SRa) from the 4-chamber view (LA) both before and after ablation (all P<0.05). In the non-AF group, there were decreased SRe levels from the 4-chamber view (LA/RA) pre-ablation compared to post-ablation (all P<0.05). Conclusion Our findings provide convincing evidence that WPW syndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period. PMID:25397668
Li, Jing-Jie; Wei, Fang; Chen, Ju-Gang; Yu, Yan-Wei; Gu, Hong-Yue; Jiang, Rui; Wu, Xiu-Li; Sun, Qian
2014-01-01
The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE). All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls. Results showed significant differences in both body mass index (BMI) and supraventricular tachycardia (SVT) duration between WPW patients and DAVNP patients (both P<0.05). Echocardiography revealed that the maximum left atrial volume (LAVmax) and the left ventricular mass index (LVMI) in diastole increased noticeably in patients with WPW compared to patients with DAVNP both before and after ablation (all P<0.05). Before ablation, there were obvious differences in the levels of SRs, SRe, and SRa from the 4-chamber view (LA) in the WPW patients group compared with patients in the DAVNP group (all P<0.05). In the AF group, there were significant differences in the levels of systolic strain rate (SRs), early diastolic strain rate (SRe), and late diastolic strain rate (SRa) from the 4-chamber view (LA) both before and after ablation (all P<0.05). In the non-AF group, there were decreased SRe levels from the 4-chamber view (LA/RA) pre-ablation compared to post-ablation (all P<0.05). Our findings provide convincing evidence that WPW syndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period.
2012-01-01
Background Retinal progenitor cells are a convenient source of cell replacement therapy in retinal degenerative disorders. The purpose of this study was to evaluate the expression patterns of the homeobox genes PAX6 and CHX10 (retinal progenitor markers) during treatment of human retinal pigment epithelium (RPE) cells with amniotic fluid (AF), RPE cells harvested from neonatal cadaver globes were cultured in a mixture of DMEM and Ham's F12 supplemented with 10% FBS. At different passages, cells were trypsinized and co-cultured with 30% AF obtained from normal fetuses of 1416 weeks gestational age. Results Compared to FBS-treated controls, AF-treated cultures exhibited special morphological changes in culture, including appearance of spheroid colonies, improved initial cell adhesion and ordered cell alignment. Cell proliferation assays indicated a remarkable increase in the proliferation rate of RPE cells cultivated in 30% AF-supplemented medium, compared with those grown in the absence of AF. Immunocytochemical analyses exhibited nuclear localization of retinal progenitor markers at a ratio of 33% and 27% for CHX10 and PAX6, respectively. This indicated a 3-fold increase in retinal progenitor markers in AF-treated cultures compared to FBS-treated controls. Real-time PCR data of retinal progenitor genes (PAX6, CHX10 and VSX-1) confirmed these results and demonstrated AF's capacity for promoting retinal progenitor cell generation. Conclusion Taken together, the results suggest that AF significantly promotes the rate of retinal progenitor cell generation, indicating that AF can be used as an enriched supplement for serum-free media used for the in vitro propagation of human progenitor cells. PMID:22490806
Generation of Elliptically Polarized Terahertz Waves from Antiferromagnetic Sandwiched Structure.
Zhou, Sheng; Zhang, Qiang; Fu, Shu-Fang; Wang, Xuan-Zhang; Song, Yu-Ling; Wang, Xiang-Guang; Qu, Xiu-Rong
2018-04-01
The generation of elliptically polarized electromagnetic wave of an antiferromagnetic (AF)/dielectric sandwiched structure in the terahertz range is studied. The frequency and external magnetic field can change the AF optical response, resulting in the generation of elliptical polarization. An especially useful geometry with high levels of the generation of elliptical polarization is found in the case where an incident electromagnetic wave perpendicularly illuminates the sandwiched structure, the AF anisotropy axis is vertical to the wave-vector and the external magnetic field is pointed along the wave-vector. In numerical calculations, the AF layer is FeF2 and the dielectric layers are ZnF2. Although the effect originates from the AF layer, it can be also influenced by the sandwiched structure. We found that the ZnF2/FeF2/ZnF2 structure possesses optimal rotation of the principal axis and ellipticity, which can reach up to about thrice that of a single FeF2 layer.
Broux, B; De Clercq, D; Decloedt, A; Ven, S; Vera, L; van Steenkiste, G; Mitchell, K; Schwarzwald, C; van Loon, G
2017-11-01
Atrial fibrillation (AF) is the most common pathological arrhythmia in horses. After successful treatment, recurrence is common. Heart rate monitors are easily applicable in horses and some devices offer basic heart rate variability (HRV) calculations. If HRV can be used to distinguish between AF and sinus rhythm (SR), this could become a monitoring tool for horses at risk for recurrence of AF. The purpose of this study was to assess whether in horses AF (before cardioversion) and SR (after cardioversion) can be differentiated based upon HRV parameters. Cohort study with internal controls. Six HRV parameters were determined in 20 horses, both in AF and in SR, at rest (2- and 5-min and 1- and 4-h recordings) and during exercise (walk and trot, 2-min recordings). Time-domain (standard deviation of the NN intervals, root mean squared successive differences in NN intervals and triangular index), frequency domain (low/high frequency ratio) and nonlinear parameters (standard deviation of the Poincaré plot [SD]1 and SD2) were used. Statistical analysis was done using paired Wilcoxon signed rank tests and receiver operating characteristic curves. HRV was higher during AF compared to SR. Results for the detection of AF were good (area under the receiver operating characteristic curve [AUC] 0.8-1) for most HRV parameters. Root mean squared successive differences in NN intervals and SD1 yielded the best results (AUC 0.9-1). Sensitivity and specificity were high for all parameters at all recordings, but highest during exercise. Although AUCs improved with longer recordings, short recordings were also good (AUC 0.8-1) for the detection of AF. In horses with frequent second degree atrioventricular block, HRV at rest is increased and recordings at walk or trot are recommended. Animals served as their own controls and there was no long-term follow-up to identify AF recurrence. AF (before cardioversion) and SR (after cardioversion) could be distinguished with HRV. This technique has promise as a monitoring tool in horses at risk for AF development. © 2017 EVJ Ltd.
Banser, Alena; Naafs, Jolanda C; Hoorweg-Nijman, Jantine Jg; van de Garde, Ewoudt Mw; van der Vorst, Marja Mj
2016-09-01
Advanced glycation end products (AGEs) are considered major contributors to microvascular and macrovascular complications in adult patients with diabetes mellitus. AGEs can be measured non-invasively with skin autofluorescence (sAF). The primary aim was to determine sAF values in children with type 1 diabetes mellitus and to study correlations between sAF values and HbA1c and mean HbA1c over the year prior to measurement In children with type 1 diabetes mellitus, sAF values were measured using the AGE Reader®. Laboratory and anthropometric values were extracted from medical charts. Correlations were studied using Pearson's correlation coefficient. Multivariable linear regression analysis was conducted to evaluate the effect of multiple study parameters on sAF values. The mean sAF value was 1.33 ± 0.36 arbitrary units (AU) in children with type 1 diabetes mellitus (n = 144). sAF values correlated positively with HbA1c measured at the same time (r = 0.485; p < 0.001), mean HbA1c over the year prior to measurement (r = 0.578; p < 0.001), age (r = 0.337; p < 0.001), duration of type 1 diabetes mellitus (r = 0.277; p = 0.001), serum triglycerides (r = 0.399; p < 0.001), and total cholesterol (r = 0.352; p = 0.001). sAF values were significantly higher in patients with non-white skin (1.56 vs. 1.27 AU, respectively, p = 0.001). In children with type 1 diabetes, sAF values correlate strongly with single HbA1c and mean HbA1c, making the non-invasive sAF measurement an interesting alternative to provide information about cumulative hyperglycemic states. To determine the value of sAF measurement in predicting long-term microvascular and macrovascular complications, further prospective follow-up studies are needed. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Wan, Huaibin; Yang, Yanmin; Zhu, Jun; Huang, Bi; Wang, Juan; Wu, Shuang; Shao, Xinghui; Zhang, Han
2015-08-01
Red cell distribution width (RDW) is associated with the incidence of atrial fibrillation (AF). The aim of this study was to evaluate the relationship between elevated RDW and long-term clinical outcomes among patients with AF. We prospectively observed 300 consecutive patients with AF (50.3% males, mean age 62.6 ± 12.9 years) between February 2009 and October 2011. Baseline RDW levels and clinical data were collected. The primary clinical outcomes of interest included all-cause mortality and the incidence of major adverse events (MAEs). During a median follow-up period of 3.2 years, 60 deaths and 92 MAEs were recorded. From the lowest to the highest RDW quartile, an increased risk of mortality (2.76, 3.98, 8.40 and 13.77 per 100 person-years, respectively) and an incidence of MAEs (6.46, 8.18, 13.79 and 20.27 per 100 person-years, respectively) were noted. In a multivariate Cox regression analysis, RDW was independently associated with both all-cause mortality (hazard ratio (HR): 1.024; 95% confidence interval (CI): 1.012-1.036, P < 0.001) and MAEs (HR: 1.012; 95% CI: 1.002-1.023, P = 0.023). A receiver operating characteristic (ROC) analysis revealed that RDW predicted both mortality and MAEs with areas under the ROC curves (AUCs) of 0.682 (P < 0.001) and 0.617 (P = 0.001); the best cutoff points were 13.85% and 13.55%, respectively. Elevated RDW is an independent predictor of long-term adverse clinical outcomes, including all-cause mortality and MAEs, among patients with AF. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Besli, Feyzullah; Basar, Cengiz; Kecebas, Mesut; Turker, Yasin
2015-03-01
This study evaluated the response to electrical cardioversion (EC) and the effect on the myocardial performance index (MPI) in patients with persistent and long-standing persistent atrial fibrillation (AF). We enrolled 103 patients (mean age 69.6 ± 8.9 years, 40.7% males) with a diagnosis of persistent and long-standing persistent AF. EC was applied to all patients after one g of amiodarone administration. Echocardiographic findings before EC were compared in patients with successful versus unsuccessful cardioversions and in patients with maintained sinus rhythm (SR) versus those with AF recurrence at the end of the first month. We also compared echocardiographic data before EC versus at the end of the first month in the same patients with maintained SR. SR was achieved in 72.8% of patients and was continued at the end of the first month in 69.3% of the patients. The MPI value of all patients was found to be 0.73 ± 0.21. The size of the left atrium was determined to be an independent predictor of the maintenance of SR at 1 month. In subgroup analyses, when we compared echocardiographic findings before EC and at the end of the first month in patients with maintained SR, the MPI (0.66 ± 0.14 vs 0.56 ± 0.09, p < 0.001) values were significantly decreased. Our study is the first to show impairment of the MPI, which is an indicator of systolic and diastolic function, in patients with persistent and long-standing persistent AF and improvement of the MPI after successful EC.
Troise, Giovanni; Cirillo, Marco; Brunelli, Federico; Tasca, Giordano; Amaducci, Andrea; Mhagna, Zen; Tomba, Margherita Dalla; Quaini, Eugenio
2004-06-01
The results of current surgical options for the treatment of permanent atrial fibrillation (AF) associated with mitral surgery are widely different, particularly in very enlarged left atria. The aim of this study was to assess the mid-term efficacy of cardiac autotransplantation for this goal, through a consistent reduction of left atrium volume and a complete isolation of the pulmonary veins. From April 2000 to September 2002, 30 patients (male/female 5/25) underwent cardiac autotransplantation for the treatment of mitral valve disease and concomitant permanent AF (>1 year). Surgical technique of bicaval heart transplantation was modified maintaining the connection of inferior vena cava in all but three cases. Twenty-eight patients had mitral valve replacement and two had mitral valve repair. Associated procedures were: aortic valve replacement (6 cases), tricuspid valve repair (2 cases), coronary re-vascularization (2 cases) and right atrium volume reduction (4 cases). No hospital death occurred; 1 patient died 3 months post-operatively for pneumonia. At a mean follow-up of 21.1+/-7.7 months (range 6-35), 26 patients (89.7%) were in sinus rhythm and 3 (10.3%) in AF. Santa Cruz Score was 0 in 3 patients, 2 in 2 patients and 4 in the remaining 24 patients (82.7%). Mean left atrial diameter and volume decreased from 65.1+/-16.4 mm (range 50-130 mm) to 49.9+/-8.4 mm (range 37-78) (P < 0.001) and from 118.3+/-68.4 ml (range 60-426) to 69.4+/-34.1 ml (range 31-226) (P = 0.001), respectively, after the operation. Cardiac autotransplantation is a safe and effective option for the treatment of permanent AF in patients with mitral valve disease and severe dilation of left atrium.
Kaitani, Kazuaki; Inoue, Koichi; Kobori, Atsushi; Nakazawa, Yuko; Ozawa, Tomoya; Kurotobi, Toshiya; Morishima, Itsuro; Miura, Fumiharu; Watanabe, Tetsuya; Masuda, Masaharu; Naito, Masaki; Fujimoto, Hajime; Nishida, Taku; Furukawa, Yoshio; Shirayama, Takeshi; Tanaka, Mariko; Okajima, Katsunori; Yao, Takenori; Egami, Yasuyuki; Satomi, Kazuhiro; Noda, Takashi; Miyamoto, Koji; Haruna, Tetsuya; Kawaji, Tetsuma; Yoshizawa, Takashi; Toyota, Toshiaki; Yahata, Mitsuhiko; Nakai, Kentaro; Sugiyama, Hiroaki; Higashi, Yukei; Ito, Makoto; Horie, Minoru; Kusano, Kengo F; Shimizu, Wataru; Kamakura, Shiro; Morimoto, Takeshi; Kimura, Takeshi; Shizuta, Satoshi
2016-02-14
Substantial portion of early arrhythmia recurrence after catheter ablation for atrial fibrillation (AF) is considered to be due to irritability in left atrium (LA) from the ablation procedure. We sought to evaluate whether 90-day use of antiarrhythmic drug (AAD) following AF ablation could reduce the incidence of early arrhythmia recurrence and thereby promote reverse remodelling of LA, leading to improved long-term clinical outcomes. A total of 2038 patients who had undergone radiofrequency catheter ablation for paroxysmal, persistent, or long-lasting AF were randomly assigned to either 90-day use of Vaughan Williams class I or III AAD (1016 patients) or control (1022 patients) group. The primary endpoint was recurrent atrial tachyarrhythmias lasting for >30 s or those requiring repeat ablation, hospital admission, or usage of class I or III AAD at 1 year, following the treatment period of 90 days post ablation. Patients assigned to AAD were associated with significantly higher event-free rate from recurrent atrial tachyarrhythmias when compared with the control group during the treatment period of 90 days [59.0 and 52.1%, respectively; adjusted hazard ratio (HR) 0.84; 95% confidence interval (CI) 0.73-0.96; P = 0.01]. However, there was no significant difference in the 1-year event-free rates from the primary endpoint between the groups (69.5 and 67.8%, respectively; adjusted HR 0.93; 95% CI 0.79-1.09; P = 0.38). Short-term use of AAD for 90 days following AF ablation reduced the incidence of recurrent atrial tachyarrhythmias during the treatment period, but it did not lead to improved clinical outcomes at the later phase. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Fractional-order difference equations for physical lattices and some applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tarasov, Vasily E., E-mail: tarasov@theory.sinp.msu.ru
2015-10-15
Fractional-order operators for physical lattice models based on the Grünwald-Letnikov fractional differences are suggested. We use an approach based on the models of lattices with long-range particle interactions. The fractional-order operators of differentiation and integration on physical lattices are represented by kernels of lattice long-range interactions. In continuum limit, these discrete operators of non-integer orders give the fractional-order derivatives and integrals with respect to coordinates of the Grünwald-Letnikov types. As examples of the fractional-order difference equations for physical lattices, we give difference analogs of the fractional nonlocal Navier-Stokes equations and the fractional nonlocal Maxwell equations for lattices with long-range interactions.more » Continuum limits of these fractional-order difference equations are also suggested.« less
NASA Astrophysics Data System (ADS)
Gauthier, N.; Fennell, A.; Prévost, B.; Uldry, A.-C.; Delley, B.; Sibille, R.; Désilets-Benoit, A.; Dabkowska, H. A.; Nilsen, G. J.; Regnault, L.-P.; White, J. S.; Niedermayer, C.; Pomjakushin, V.; Bianchi, A. D.; Kenzelmann, M.
2017-04-01
Magnetic frustration and low dimensionality can prevent long-range magnetic order and lead to exotic correlated ground states. SrDy2O4 consists of magnetic Dy3 + ions forming magnetically frustrated zigzag chains along the c axis and shows no long-range order to temperatures as low as T =60 mK. We carried out neutron scattering and ac magnetic susceptibility measurements using powder and single crystals of SrDy2O4 . Diffuse neutron scattering indicates strong one-dimensional (1D) magnetic correlations along the chain direction that can be qualitatively accounted for by the axial next-nearest-neighbor Ising model with nearest-neighbor and next-nearest-neighbor exchange J1=0.3 meV and J2=0.2 meV, respectively. Three-dimensional (3D) correlations become important below T*≈0.7 K. At T =60 mK, the short-range correlations are characterized by a putative propagation vector k1 /2=(0 ,1/2 ,1/2 ) . We argue that the absence of long-range order arises from the presence of slowly decaying 1D domain walls that are trapped due to 3D correlations. This stabilizes a low-temperature phase without long-range magnetic order, but with well-ordered chain segments separated by slowly moving domain walls.
Microfluidic Pumps Containing Teflon [Trademark] AF Diaphragms
NASA Technical Reports Server (NTRS)
Willis, Peter; White, Victor; Grunthaner, Frank; Ikeda, Mike; Mathies, Richard A.
2009-01-01
Microfluidic pumps and valves based on pneumatically actuated diaphragms made of Teflon AF polymers are being developed for incorporation into laboratory-on-a-chip devices that must perform well over temperature ranges wider than those of prior diaphragm-based microfluidic pumps and valves. Other potential applications include implanted biomedical microfluidic devices, wherein the biocompatability of Teflon AF polymers would be highly advantageous. These pumps and valves have been demonstrated to function stably after cycling through temperatures from -125 to 120 C. These pumps and valves are intended to be successors to similar prior pumps and valves containing diaphragms made of polydimethylsiloxane (PDMS) [commonly known as silicone rubber]. The PDMS-containing valves ae designed to function stably only within the temperature range from 5 to 80 C. Undesirably, PDMS membranes are somwehat porous and retain water. PDMS is especially unsuitable for use at temperatures below 0 C because the formation of ice crystals increases porosity and introduces microshear.
Volti, Theodora; Burbidge, David; Collins, Clive; Asten, Michael W.; Odum, Jackson K.; Stephenson, William J.; Pascal, Chris; Holzschuh, Josef
2016-01-01
Although the time‐averaged shear‐wave velocity down to 30 m depth (VS30) can be a proxy for estimating earthquake ground‐motion amplification, significant controversy exists about its limitations when used as a single parameter for the prediction of amplification. To examine this question in absence of relevant strong‐motion records, we use a range of different methods to measure the shear‐wave velocity profiles and the resulting theoretical site amplification factors (AFs) for 30 sites in the Newcastle area, Australia, in a series of blind comparison studies. The multimethod approach used here combines past seismic cone penetrometer and spectral analysis of surface‐wave data, with newly acquired horizontal‐to‐vertical spectral ratio, passive‐source surface‐wave spatial autocorrelation (SPAC), refraction microtremor (ReMi), and multichannel analysis of surface‐wave data. The various measurement techniques predicted a range of different AFs. The SPAC and ReMi techniques have the smallest overall deviation from the median AF for the majority of sites. We show that VS30 can be related to spectral response above a period T of 0.5 s but not necessarily with the maximum amplification according to the modeling done based on the measured shear‐wave velocity profiles. Both VS30 and AF values are influenced by the velocity ratio between bedrock and overlying sediments and the presence of surficial thin low‐velocity layers (<2 m thick and <150 m/s), but the velocity ratio is what mostly affects the AF. At 0.2
Automatic detection of atrial fibrillation in cardiac vibration signals.
Brueser, C; Diesel, J; Zink, M D H; Winter, S; Schauerte, P; Leonhardt, S
2013-01-01
We present a study on the feasibility of the automatic detection of atrial fibrillation (AF) from cardiac vibration signals (ballistocardiograms/BCGs) recorded by unobtrusive bedmounted sensors. The proposed system is intended as a screening and monitoring tool in home-healthcare applications and not as a replacement for ECG-based methods used in clinical environments. Based on BCG data recorded in a study with 10 AF patients, we evaluate and rank seven popular machine learning algorithms (naive Bayes, linear and quadratic discriminant analysis, support vector machines, random forests as well as bagged and boosted trees) for their performance in separating 30 s long BCG epochs into one of three classes: sinus rhythm, atrial fibrillation, and artifact. For each algorithm, feature subsets of a set of statistical time-frequency-domain and time-domain features were selected based on the mutual information between features and class labels as well as first- and second-order interactions among features. The classifiers were evaluated on a set of 856 epochs by means of 10-fold cross-validation. The best algorithm (random forests) achieved a Matthews correlation coefficient, mean sensitivity, and mean specificity of 0.921, 0.938, and 0.982, respectively.
Atrial fibrillation patients with isolated pulmonary veins: Is sinus rhythm achievable?
Szilágyi, Judit; Marcus, Gregory M; Badhwar, Nitish; Lee, Byron K; Lee, Randall J; Vedantham, Vasanth; Tseng, Zian H; Walters, Tomos; Scheinman, Melvin; Olgin, Jeffrey; Gerstenfeld, Edward P
2017-07-01
The cornerstone of atrial fibrillation (AF) ablation is isolation of the pulmonary veins (PVs). Patients with recurrent AF undergoing repeat ablation usually have PV reconnection (PVr). The ablation strategy and outcome of patients undergoing repeat ablation who have persistent isolation of all PVs (PVi) at the time of repeat ablation is unknown. We studied consecutive patients with recurrent AF undergoing repeat ablation and compared patients with PVi to those with PVr. One hundred fifty-two patients underwent repeat ablation, and of these, 25 patients (16.4%) had PVi. Patients with PVi underwent ablation targeting any isoproterenol induced AF triggers, atrial substrate, or inducible atrial tachycardias or flutters. Patients with PVi compared to PVr were more likely to have a history of persistent AF (64% vs. 26%; P < 0.0001), obesity (BMI 30.4 vs. 28.2; P = 0.05), and prior use of contact force sensing catheters (28% vs. 0.8%, P < 0.0001). After a mean follow-up of 19 ± 15 months, 56% of PVi patients remained in sinus rhythm compared to 76.3% of PVr patients (P = 0.036). In a multivariable model, PVi patients and those with cardiomyopathy had a higher risk of recurrent atrial tachyarrhythmias (HR = 3.6 95%, CI 1.6-8.3, P = 0.002 and HR = 6.2, 95% CI 2.3-16.3, P < 0.0001, respectively). In patients who have all PVs isolated at the time of the redo AF ablation, a strategy of targeting non-PV AF triggers and inducible flutters can still lead to AF freedom in more than half of patients. Patients with PVr, however, have a better long-term outcome. © 2017 Wiley Periodicals, Inc.
Iselin, Anne-Marie R.; Gully, Kevin J.
2011-01-01
This paper examines the sustainability and outcome of Alternatives for Families: A Cognitive-Behavioral Therapy (AF-CBT) as delivered by practitioners in a community-based child protection program who had received training in the model several years earlier. Formerly described as Abuse-Focused CBT, AF-CBT is an evidence-based treatment (EBT) for child physical abuse and family aggression/conflict that was included in the National Child Traumatic Stress Network’s initial EBT dissemination efforts in 2002. Seven practitioners participated in a year-long Learning Collaborative in AF-CBT and in similar training programs for 4 other EBTs. The agency’s routine data collection system was used to document the clinical and adjustment outcomes of 52 families presenting with a physically abused child who received their services between 2 and 5 years after the AF-CBT training had ended. Measures of the use of all 5 EBTs documented their frequency, internal consistency, and intercorrelations. Controlling for the unique content of the other four EBTs, the amount of AF-CBT Abuse-specific content delivered was related to improvements on standardized parent rating scales (i.e., child externalizing behavior, anger, anxiety, social competence) and both parent and clinician ratings of the child’s adjustment at discharge (i.e., child more safe, less scared/sad, more appropriate with peers). The amount of AF-CBT General content was related to a few discharge ratings (better child prognosis, helpfulness to parents). These novel data provide suggestive evidence for the sustainability and clinical benefits of AF-CBT in an existing community clinic serving physically abused children and their families, and are discussed in the context of key developments in the treatment model and dissemination literature. PMID:21354619
Andrade, Jason; Khairy, Paul; Dobrev, Dobromir; Nattel, Stanley
2014-04-25
Atrial fibrillation (AF) is the most common arrhythmia (estimated lifetime risk, 22%-26%). The aim of this article is to review the clinical epidemiological features of AF and to relate them to underlying mechanisms. Long-established risk factors for AF include aging, male sex, hypertension, valve disease, left ventricular dysfunction, obesity, and alcohol consumption. Emerging risk factors include prehypertension, increased pulse pressure, obstructive sleep apnea, high-level physical training, diastolic dysfunction, predisposing gene variants, hypertrophic cardiomyopathy, and congenital heart disease. Potential risk factors are coronary artery disease, kidney disease, systemic inflammation, pericardial fat, and tobacco use. AF has substantial population health consequences, including impaired quality of life, increased hospitalization rates, stroke occurrence, and increased medical costs. The pathophysiology of AF centers around 4 general types of disturbances that promote ectopic firing and reentrant mechanisms, and include the following: (1) ion channel dysfunction, (2) Ca(2+)-handling abnormalities, (3) structural remodeling, and (4) autonomic neural dysregulation. Aging, hypertension, valve disease, heart failure, myocardial infarction, obesity, smoking, diabetes mellitus, thyroid dysfunction, and endurance exercise training all cause structural remodeling. Heart failure and prior atrial infarction also cause Ca(2+)-handling abnormalities that lead to focal ectopic firing via delayed afterdepolarizations/triggered activity. Neural dysregulation is central to atrial arrhythmogenesis associated with endurance exercise training and occlusive coronary artery disease. Monogenic causes of AF typically promote the arrhythmia via ion channel dysfunction, but the mechanisms of the more common polygenic risk factors are still poorly understood and under intense investigation. Better recognition of the clinical epidemiology of AF, as well as an improved appreciation of the underlying mechanisms, is needed to develop improved methods for AF prevention and management.
Dewland, Thomas A; Soliman, Elsayed Z; Yamal, Jose-Miguel; Davis, Barry R; Alonso, Alvaro; Albert, Christine M; Simpson, Lara M; Haywood, L Julian; Marcus, Gregory M
2017-12-01
Although atrial fibrillation (AF) guidelines indicate that pharmacological blockade of the renin-angiotensin system may be considered for primary AF prevention in hypertensive patients, previous studies have yielded conflicting results. We sought to determine whether randomization to lisinopril reduces incident AF or atrial flutter (AFL) compared with chlorthalidone in a large clinical trial cohort with extended post-trial surveillance. We performed a secondary analysis of the ALLHAT (Antihypertensive and Lipid-Lowering Treatment to Prevent Heart Attack Trial), a randomized, double-blind, active-controlled clinical trial that enrolled hypertensive individuals ≥55 years of age with at least one other cardiovascular risk factor. Participants were randomly assigned to receive amlodipine, lisinopril, or chlorthalidone. Individuals with elevated fasting low-density lipoprotein cholesterol levels were also randomized to pravastatin versus usual care. The primary outcome was the development of either AF or AFL as diagnosed by serial study ECGs or by Medicare claims data. Among 14 837 participants without prevalent AF or AFL, 2514 developed AF/AFL during a mean 7.5±3.2 years of follow-up. Compared with chlorthalidone, randomization to either lisinopril (hazard ratio, 1.04; 95% confidence interval, 0.94-1.15; P =0.46) or amlodipine (hazard ratio, 0.93; 95% confidence interval, 0.84-1.03; P =0.16) was not associated with a significant reduction in incident AF/AFL. Compared with chlorthalidone, treatment with lisinopril is not associated with a meaningful reduction in incident AF or AFL among older adults with a history of hypertension. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00000542. © 2017 American Heart Association, Inc.
Ma, Xinbo; Wong, Pak Kin; Zhao, Jing; Xie, Zhengchao
2016-12-28
Active front steering (AFS) is an emerging technology to improve the vehicle cornering stability by introducing an additional small steering angle to the driver's input. This paper proposes an AFS system with a variable gear ratio steering (VGRS) actuator which is controlled by using the sliding mode control (SMC) strategy to improve the cornering stability of vehicles. In the design of an AFS system, different sensors are considered to measure the vehicle state, and the mechanism of the AFS system is also modelled in detail. Moreover, in order to improve the cornering stability of vehicles, two dependent objectives, namely sideslip angle and yaw rate, are considered together in the design of SMC strategy. By evaluating the cornering performance, Sine with Dwell and accident avoidance tests are conducted, and the simulation results indicate that the proposed SMC strategy is capable of improving the cornering stability of vehicles in practice.
Leeman, Mats; Choi, Jaeyeong; Hansson, Sebastian; Storm, Matilda Ulmius; Nilsson, Lars
2018-05-29
The analysis of aggregates of therapeutic proteins is crucial in order to ensure efficacy and patient safety. Typically, the analysis is performed in the finished formulation to ensure that aggregates are not present. An important question is, however, what happens to therapeutic proteins, with regard to oligomerization and aggregation, after they have been administrated (i.e., in the blood). In this paper, the separation of whole blood, plasma, and serum is shown using asymmetric flow field-flow fractionation (AF4) with a minimum of sample pre-treatment. Furthermore, the analysis and size characterization of a fluorescent antibody in blood plasma using AF4 are demonstrated. The results show the suitability and strength of AF4 for blood analysis and open new important routes for the analysis and characterization of therapeutic proteins in the blood.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong, X.; Rungger, I.; Zapol, P.
Understanding electronic properties of substoichiometric phases of titanium oxide such as Magneli phase Ti 4O 7 is crucial in designing and modeling resistive switching devices. Here we present our study on Magneli phase Ti 4O 7 together with rutile TiO 2 and Ti 2O 3 using density functional theory methods with atomic-orbital-based self-interaction correction (ASIC). We predict a new antiferromagnetic (AF) ground state in the low temperature (LT) phase, and we explain energy difference with a competing AF state using a Heisenberg model. The predicted energy ordering of these states in the LT phase is calculated to be robust inmore » a wide range of modeled isotropic strain. We have also investigated the dependence of the electronic structures of the Ti-O phases on stoichiometry. The splitting of titanium t 2g orbitals is enhanced with increasing oxygen deficiency as Ti-O is reduced. Furthermore, the electronic properties of all these phases can be reasonably well described by applying ASIC with a "standard" value for transition metal oxides of the empirical parameter alpha of 0.5 representing the magnitude of the applied self-interaction correction.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong, X.; Rungger, I.; Zapol, P.
Understanding electronic properties of substoichiometric phases of titanium oxide such as Magneli phase Ti4O7 is crucial in designing and modeling resistive switching devices. Here we present our study on Magneli phase Ti4O7 together with rutile TiO2 and Ti2O3 using density functional theory methods with atomic-orbital-based self-interaction correction (ASIC). We predict a new antiferromagnetic (AF) ground state in the low temperature (LT) phase, and we explain energy difference with a competing AF state using a Heisenberg model. The predicted energy ordering of these states in the LT phase is calculated to be robust in a wide range of modeled isotropic strain.more » We have also investigated the dependence of the electronic structures of the Ti-O phases on stoichiometry. The splitting of titanium t(2g) orbitals is enhanced with increasing oxygen deficiency as Ti-O is reduced. The electronic properties of all these phases can be reasonably well described by applying ASIC with a "standard" value for transition metal oxides of the empirical parameter alpha of 0.5 representing the magnitude of the applied self-interaction correction.« less
ERIC Educational Resources Information Center
Hermansen, Hege; Nerland, Monika
2014-01-01
In recent years, the concept of Assessment for Learning (AfL) has travelled across countries, giving rise to a range of educational policy initiatives and school development projects. While researchers have focused on issues such as how formative assessment can support student learning and lead to more efficient classroom practices, less attention…
GdPtPb: A noncollinear antiferromagnet with distorted kagome lattice
Manni, S.; Bud'ko, Sergey L.; Canfield, Paul C.
2017-08-24
In the spirit of searching for Gd-based, frustrated, rare earth magnets, we have found antiferomagnetism (AF) in GdPtPb, which crystallizes in the ZrNiAl-type structure that has a distorted kagome lattice of Gd triangles. Single crystals were grown and investigated using structural, magnetic, transport, and thermodynamic measurements. GdPtPb orders antiferromagnetically at 15.5 K, arguably with a planar, noncollinear structure. The high temperature magnetic susceptibility data reveal an “anti-frustration” behavior having a frustration parameter, |f| = |Θ|/T N = 0.25, which can be explained by mean field theory within a two-sublattice model. Here, the study of the magnetic phase diagram down tomore » T = 1.8K reveals a change of magnetic structure through a metamagnetic transition at around 20 kOe and the disappearance of the AF ordering near 140 kOe. In total, our work indicates that GdPtPb can serve as an example of a planar, noncollinear AF with a distorted kagome magnetic sublattice.« less
Ortega-Beltran, Alejandro; Moral, Juan; Puckett, Ryan D; Morgan, David P; Cotty, Peter J; Michailides, Themis J
2018-01-01
Interactions between pathogenic and nonpathogenic fungal species in the tree canopy are complex and can determine if disease will manifest in the plant and in other organisms such as honey bees. Seasonal dynamics of fungi were studied in an almond orchard in California where experimental release of the atoxigenic biopesticide Aspergillus flavus AF36 to displace toxigenic Aspergillus strains has been conducted for five years. The presence of the vegetative compatibility group (VCG) YV36, to which AF36 belongs, in the blossoms, and the honey bees that attend these blossoms, was assessed. In blossoms, A. flavus frequencies ranged from 0 to 4.5%, depending on the year of study. Frequencies of honey bees carrying A. flavus ranged from 6.5 to 10%. Only one A. flavus isolate recovered from a blossom in 2016 belonged to YV36, while members of the VCG were not detected contaminating honey bees. Exposure of pollinator honey bees to AF36 was detected to be very low. The density of several Aspergillus species was found to increase during almond hull split and throughout the final stages of maturation; this also occurred in pistachio orchards during the maturation period. Additionally, we found that AF36 effectively limited almond aflatoxin contamination in laboratory assays. This study provides knowledge and understanding of the seasonal dynamics of Aspergillus fungi and will help design aflatoxin management strategies for almond. The evidence of the low levels of VCG YV36 encountered on almond blossoms and bees during pollination and AF36's effectiveness in limiting aflatoxin contamination in almond provided additional support for the registration of AF36 with USEPA to use in almond in California.
Aguilera Alcaraz, Beatriz M; Abellán Huerta, José; Carbayo Herencia, Julio Antonio; Ariza Copado, Consuelo; Hernández Menárguez, Fernando; Abellán Alemán, José
Atrial fibrillation (AF) is the most common cardiac arrhythmia. To assess the need for anticoagulation is essential for its management. Our objective was to investigate whether the indication of anticoagulation was adequate in patients diagnosed with non-valvular AF, given the CHA2-DS2-VASc scale, measuring the International Normalizad Ratio range (INR) in patients treated with anti-vitamin K drugs. This is an observational and cross sectional study. 232 patients with atrial fibrillation were included. We analyzed demographic, the CHA2-DS2-VASc and HAS-BLED variables, the treatment and INR values for 6 consequentive months. The confrontation of variables was performed using chi-square and Mantel-Haenzel test. The prevalence of AF was 1.05%. The 88.4% had CHA2-DS2-VASc ≥ 2. The 71.1% were taking anticoagulants, of which 58.2% were under antivitamin k. The 46.7% of patients taking antivitamin K, presented inadequate range of INR. There was a greater prescription of antivitamin k in patients with persistent or permanent AF compared to the paroxysmal form (62.8 vs. 37.2% p<.001). The use of drugs that increase bleeding was associated with a worse control of INR after adjustment for the main variables of clinical relevance (odds ratio 2.17 [1.02-4.59], p=.043). The level of anticoagulation with antivitamin K was inadequate in our sample, despite a proper follow up and adherence to treatment. Patients with paroxysmal AF received less antivitamin K than those with persistent/permanent AF. Copyright © 2017 Sociedad Española de Arteriosclerosis. Publicado por Elsevier España, S.L.U. All rights reserved.
Extracting Uranium from Seawater: Promising AF Series Adsorbents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Das, S.; Oyola, Y.; Mayes, Richard T.
A new family of high-surface-area polyethylene fiber adsorbents named the AF series was recently developed at the Oak Ridge National Laboratory (ORNL). The AF series adsorbents were synthesized by radiation-induced graft polymerization of acrylonitrile and itaconic acid (at different monomer/comonomer mol ratios) onto high surface area polyethylene fibers. The degree of grafting (%DOG) of AF series adsorbents was found to be 154-354%. The grafted nitrile groups were converted to amidoxime groups by treating with hydroxylamine. The amidoximated adsorbents were then conditioned with 0.44 M KOH at 80 °C followed by screening at ORNL with sodium-based synthetic aqueous solution, spiked withmore » 8 ppm uranium. The uranium adsorption capacity in simulated seawater screening ranged from 170 to 200 g-U/kg-ads irrespective of %DOG. A monomer/comonomer molar ratio in the range of 7.57-10.14 seemed to be optimum for highest uranium loading capacity. Subsequently, the adsorbents were also tested with natural seawater at Pacific Northwest National Laboratory (PNNL) using flow-through column experiments to determine uranium loading capacity with varying KOH conditioning times at 80 °C. The highest adsorption capacity of AF1 measured after 56 days of marine testing was demonstrated as 3.9 g-U/kg-adsorbent and 3.2 g-U/kg-adsorbent for 1 and 3 h of KOH conditioning at 80 °C, respectively. Based on capacity values of several AF1 samples, it was observed that changing KOH conditioning from 1 to 3 h at 80 °C resulted in a 22-27% decrease in uranium adsorption capacity in seawater.« less
Brace, Robert A; Anderson, Debra F; Cheung, Cecilia Y
2014-11-15
Experimentation in late-gestation fetal sheep has suggested that regulation of amniotic fluid (AF) volume occurs primarily by modulating the rate of intramembranous transport of water and solutes across the amnion into underlying fetal blood vessels. In order to gain insight into intramembranous transport mechanisms, we developed a computer model that allows simulation of experimentally measured changes in AF volume and composition over time. The model included fetal urine excretion and lung liquid secretion as inflows into the amniotic compartment plus fetal swallowing and intramembranous absorption as outflows. By using experimental flows and solute concentrations for urine, lung liquid, and swallowed fluid in combination with the passive and active transport mechanisms of the intramembranous pathway, we simulated AF responses to basal conditions, intra-amniotic fluid infusions, fetal intravascular infusions, urine replacement, and tracheoesophageal occlusion. The experimental data are consistent with four intramembranous transport mechanisms acting in concert: 1) an active unidirectional bulk transport of AF with all dissolved solutes out of AF into fetal blood presumably by vesicles; 2) passive bidirectional diffusion of solutes, such as sodium and chloride, between fetal blood and AF; 3) passive bidirectional water movement between AF and fetal blood; and 4) unidirectional transport of lactate into the AF. Further, only unidirectional bulk transport is dynamically regulated. The simulations also identified areas for future study: 1) identifying intramembranous stimulators and inhibitors, 2) determining the semipermeability characteristics of the intramembranous pathway, and 3) characterizing the vesicles that are the primary mediators of intramembranous transport. Copyright © 2014 the American Physiological Society.
Capturing the crystalline phase of two-dimensional nanocrystal superlattices in action.
Jiang, Zhang; Lin, Xiao-Min; Sprung, Michael; Narayanan, Suresh; Wang, Jin
2010-03-10
Critical photonic, electronic, and magnetic applications of two-dimensional nanocrystal superlattices often require nanostructures in perfect single-crystal phases with long-range order and limited defects. Here we discovered a crystalline phase with quasi-long-range positional order for two-dimensional nanocrystal superlattice domains self-assembled at the liquid-air interface during droplet evaporation, using in situ time-resolved X-ray scattering along with rigorous theories on two dimensional crystal structures. Surprisingly, it was observed that drying these superlattice domains preserved only an orientational order but not a long-range positional order, also supported by quantitative analysis of transmission electron microscopy images.
A Missense Variant in PLEC Increases Risk of Atrial Fibrillation.
Thorolfsdottir, Rosa B; Sveinbjornsson, Gardar; Sulem, Patrick; Helgadottir, Anna; Gretarsdottir, Solveig; Benonisdottir, Stefania; Magnusdottir, Audur; Davidsson, Olafur B; Rajamani, Sridharan; Roden, Dan M; Darbar, Dawood; Pedersen, Terje R; Sabatine, Marc S; Jonsdottir, Ingileif; Arnar, David O; Thorsteinsdottir, Unnur; Gudbjartsson, Daniel F; Holm, Hilma; Stefansson, Kari
2017-10-24
Genome-wide association studies (GWAS) have yielded variants at >30 loci that associate with atrial fibrillation (AF), including rare coding mutations in the sarcomere genes MYH6 and MYL4. The aim of this study was to search for novel AF associations and in doing so gain insights into the mechanisms whereby variants affect AF risk, using electrocardiogram (ECG) measurements. The authors performed a GWAS of 14,255 AF cases and 374,939 controls, using whole-genome sequence data from the Icelandic population, and tested novel signals in 2,002 non-Icelandic cases and 12,324 controls. They then tested the AF variants for effect on cardiac electrical function by using measurements in 289,297 ECGs from 62,974 individuals. The authors discovered 2 novel AF variants, the intergenic variant rs72700114, between the genes LINC01142 and METTL11B (risk allele frequency = 8.1%; odds ratio [OR]: 1.26; p = 3.1 × 10 -18 ), and the missense variant p.Gly4098Ser in PLEC (frequency = 1.2%; OR: 1.55; p = 8.0 × 10 -10 ), encoding plectin, a cytoskeletal cross-linking protein that contributes to integrity of cardiac tissue. The authors also confirmed 29 reported variants. p.Gly4098Ser in PLEC significantly affects various ECG measurements in the absence of AF. Other AF variants have diverse effects on the conduction system, ranging from none to extensive. The discovery of a missense variant in PLEC affecting AF combined with recent discoveries of variants in the sarcomere genes MYH6 and MYL4 points to an important role of myocardial structure in the pathogenesis of the disease. The diverse associations between AF variants and ECG measurements suggest fundamentally different categories of mechanisms contributing to the development of AF. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
The Changing Landscape for Stroke Prevention in AF: Findings From the GLORIA-AF Registry Phase 2.
Huisman, Menno V; Rothman, Kenneth J; Paquette, Miney; Teutsch, Christine; Diener, Hans-Christoph; Dubner, Sergio J; Halperin, Jonathan L; Ma, Chang Sheng; Zint, Kristina; Elsaesser, Amelie; Bartels, Dorothee B; Lip, Gregory Y H
2017-02-21
GLORIA-AF (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients with Atrial Fibrillation) is a prospective, global registry program describing antithrombotic treatment patterns in patients with newly diagnosed nonvalvular atrial fibrillation at risk of stroke. Phase 2 began when dabigatran, the first non-vitamin K antagonist oral anticoagulant (NOAC), became available. This study sought to describe phase 2 baseline data and compare these with the pre-NOAC era collected during phase 1. During phase 2, 15,641 consenting patients were enrolled (November 2011 to December 2014); 15,092 were eligible. This pre-specified cross-sectional analysis describes eligible patients' baseline characteristics. Atrial fibrillation disease characteristics, medical outcomes, and concomitant diseases and medications were collected. Data were analyzed using descriptive statistics. Of the total patients, 45.5% were female; median age was 71 (interquartile range: 64, 78) years. Patients were from Europe (47.1%), North America (22.5%), Asia (20.3%), Latin America (6.0%), and the Middle East/Africa (4.0%). Most had high stroke risk (CHA 2 DS 2 -VASc [Congestive heart failure, Hypertension, Age ≥75 years, Diabetes mellitus, previous Stroke, Vascular disease, Age 65 to 74 years, Sex category] score ≥2; 86.1%); 13.9% had moderate risk (CHA 2 DS 2 -VASc = 1). Overall, 79.9% received oral anticoagulants, of whom 47.6% received NOAC and 32.3% vitamin K antagonists (VKA); 12.1% received antiplatelet agents; 7.8% received no antithrombotic treatment. For comparison, the proportion of phase 1 patients (of N = 1,063 all eligible) prescribed VKA was 32.8%, acetylsalicylic acid 41.7%, and no therapy 20.2%. In Europe in phase 2, treatment with NOAC was more common than VKA (52.3% and 37.8%, respectively); 6.0% of patients received antiplatelet treatment; and 3.8% received no antithrombotic treatment. In North America, 52.1%, 26.2%, and 14.0% of patients received NOAC, VKA, and antiplatelet drugs, respectively; 7.5% received no antithrombotic treatment. NOAC use was less common in Asia (27.7%), where 27.5% of patients received VKA, 25.0% antiplatelet drugs, and 19.8% no antithrombotic treatment. The baseline data from GLORIA-AF phase 2 demonstrate that in newly diagnosed nonvalvular atrial fibrillation patients, NOAC have been highly adopted into practice, becoming more frequently prescribed than VKA in Europe and North America. Worldwide, however, a large proportion of patients remain undertreated, particularly in Asia and North America. (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients With Atrial Fibrillation [GLORIA-AF]; NCT01468701). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
2015-09-01
Complex 2 ( LH2 ) of Rhodobacter sphaeroides with Two- Dimensional Spectroscopy” J. Chem. Phys. 139, 155101 2013. A.F. Fidler, V.P. Singh, P.D. Long...P.D. Dahlberg, and G.S. Engel, “Time Scales of Coherent Dynamics in the Light-Harvesting Complex 2 ( LH2 ) of Rhodobacter sphaeroides” J. Phys. Chem...Spectroscopy of the Light-harvesting Complex LH2 ” Opt. Lett. 36:9 1665-1667 2011 E. Harel, A.F. Fidler, and G.S. Engel, “Single-Shot GRadient
Factors in Software Quality. Volume I. Concepts and Definitions of Software Quality
1977-11-01
FLEXIBILITY COMPLEXITY EXPANDABILITY PRECISION DOCUMENTATION TOLERANCE REPAIRABILITY COMPATABIL ITY SERVICEABILITY 2-4 AiI1I~3~I!-T A1 11 NI AIiB 9l 0...applications. Several standard documents are required by DOD/AF’ regulations . The following references were used to compile the rFpnge of documents...documents are specified by the AF regulations or SPO-local regulations listed above. Each ot the document types for a long life/high cost software
The definition of success in atrial fibrillation ablation surgery.
Hunter, Steven
2014-01-01
In spite of recent attempts to define and clarify the treatment endpoints in atrial fibrillation (AF) ablation surgery, the definition of success has remained blurred. It is of importance to address the burden of AF in the non-symptomatic population. Thromboembolic events invariably blight the outcomes, therefore freedom from stroke must be incorporated into any definition of success and guidelines. It is essential to meticulously study the long-term outcomes of an unsuccessful treatment as a supplement to the definition of success.
Multifunctional Composites with Applications to Energy Performance and Efficiency
2011-08-01
surface for comparing the effects of processing. Parylene/ Teflon AF adhesion was measured using a modified tape test. Samples were razor cut (3-6...lines, 2 mm spacing ) at 0 and 90 degrees to the tape -pull direction. SEMicro CHT tape (synthetic rubber adhesive, 12 to 25 mm wide x 75 mm long) was...surface, a thin layer of Teflon AF (~200 nm) is spin- coated for hydrophobicity. Small drops of ionic liquids in contact with a conductive probe are
Chen, Weiming; Wang, An; Lin, Chia-Ying; Mo, Xiumei; Ye, Xiaojian
2018-01-01
Introduction Herniation of the nucleus pulposus (NP) because of defects in the annulus fibrosus (AF) is a well-known cause of low back pain. Defects in the AF thus remain a surgical challenge, and efforts have been made to develop new techniques for closure and repair. In this study, we developed an electrospun aligned nanoyarn scaffold (AYS) and nanoyarn/three-dimensional porous nanofibrous hybrid scaffold (HS) for AF tissue engineering. Methods The AYS was fabricated via conjugated electrospinning, while the aligned nanofibrous scaffold (AFS) was prepared by traditional electrospinning as a baseline scaffold. The HS was constructed by freeze-drying and cross-linking methods. Scanning electron microscopy and mechanical measurement were used to characterize the properties of these scaffolds. Bone marrow derived mesenchymal stem cells (BMSCs) were seeded on scaffolds, and cell proliferation was determined by CCK-8 assay, while cell infiltration and differentiation were assessed by histological measurement and quantitative real-time polymerase chain reaction, respectively. Results Morphological measurements showed that AYS presented a relatively better three-dimensional structure with larger pore sizes, higher porosity, and better fibers’ alignment compared to AFS. Mechanical testing demonstrated that the tensile property of AFS and AYS was qualitatively similar to the native AF tissue, albeit to a lesser extent. When BMSCs were seeded and cultured on these scaffolds, the number of cells cultured on HS and AYS was found to be significantly higher than that on AFS and culture plate after 7 days of culture (P<0.05). In addition, cell infiltration was significantly higher in HS when compared with AFS and AYS (P<0.05). A part of BMSCs ingressed into the inner part of AYS upon long-term in vitro culture. No significant difference was observed between AFS and AYS in terms of the median infiltration depth (P>0.05). BMSCs seeded on AYS demonstrated an increased expression of COL1A1, while the expression levels of SOX-9, COL2A1, and Aggrecan were higher in HS compared to other scaffolds (P<0.05). Conclusion These findings indicate that HS makes a proper scaffold for the AF tissue engineering as it replicates the axial compression and tensile property of AF, thereby providing a better platform for cell infiltration and cell–scaffold interaction. PMID:29588584
Ma, Jun; He, Yunfei; Liu, Xilin; Chen, Weiming; Wang, An; Lin, Chia-Ying; Mo, Xiumei; Ye, Xiaojian
2018-01-01
Herniation of the nucleus pulposus (NP) because of defects in the annulus fibrosus (AF) is a well-known cause of low back pain. Defects in the AF thus remain a surgical challenge, and efforts have been made to develop new techniques for closure and repair. In this study, we developed an electrospun aligned nanoyarn scaffold (AYS) and nanoyarn/three-dimensional porous nanofibrous hybrid scaffold (HS) for AF tissue engineering. The AYS was fabricated via conjugated electrospinning, while the aligned nanofibrous scaffold (AFS) was prepared by traditional electrospinning as a baseline scaffold. The HS was constructed by freeze-drying and cross-linking methods. Scanning electron microscopy and mechanical measurement were used to characterize the properties of these scaffolds. Bone marrow derived mesenchymal stem cells (BMSCs) were seeded on scaffolds, and cell proliferation was determined by CCK-8 assay, while cell infiltration and differentiation were assessed by histological measurement and quantitative real-time polymerase chain reaction, respectively. Morphological measurements showed that AYS presented a relatively better three-dimensional structure with larger pore sizes, higher porosity, and better fibers' alignment compared to AFS. Mechanical testing demonstrated that the tensile property of AFS and AYS was qualitatively similar to the native AF tissue, albeit to a lesser extent. When BMSCs were seeded and cultured on these scaffolds, the number of cells cultured on HS and AYS was found to be significantly higher than that on AFS and culture plate after 7 days of culture ( P <0.05). In addition, cell infiltration was significantly higher in HS when compared with AFS and AYS ( P <0.05). A part of BMSCs ingressed into the inner part of AYS upon long-term in vitro culture. No significant difference was observed between AFS and AYS in terms of the median infiltration depth ( P >0.05). BMSCs seeded on AYS demonstrated an increased expression of COL1A1 , while the expression levels of SOX-9 , COL2A1 , and Aggrecan were higher in HS compared to other scaffolds ( P <0.05). These findings indicate that HS makes a proper scaffold for the AF tissue engineering as it replicates the axial compression and tensile property of AF, thereby providing a better platform for cell infiltration and cell-scaffold interaction.
Fraile Rodríguez, Arantxa; Basaran, Ali C.; Morales, Rafael; ...
2015-11-20
In this work, using photoemission electron microscopy combined with x-ray magnetic circular dichroism we show that a progressive spatial confinement of a ferromagnet (FM), either through thickness variation or laterally via patterning, actively controls the domains of uncompensated spins in the antiferromagnet (AF) in exchange-biased systems. Direct observations of the spin structure in both sides of the FM/AF interface in a model system, Ni/FeF 2, show that the spin structure is determined by the balance between the competing FM and AF magnetic energies. Coexistence of exchange bias domains, with opposite directions, can be established in Ni/FeF 2 bilayers for Nimore » thicknesses below 10 nm. Patterning the Ni/FeF 2 heterostructures with antidots destabilizes the FM state, enhancing the formation of opposite exchange bias domains below a critical antidot separation of the order of a few FeF 2 crystal domains. The results suggest that dimensional confinement of the FM may be used to manipulate the AF spin structure in spintronic devices and ultrahigh-density information storage media. Lastly, the underlying mechanism of the uncompensated AF domain formation in Ni/FeF 2 may be generic to other magnetic systems with complex noncollinear FM/AF spin structures.« less
Kitchen, Kaitlyn; Nicoll, Kaley
2012-01-01
Exercise and leisure activities provide physical and psychosocial benefits to people with multiple sclerosis (MS) and can enhance their quality of life. In Winnipeg, Manitoba, Canada, people with MS have reported barriers to their participation in local MS-specific aquafitness (AF) programs. Therefore, a formal exploration of the accessibility of local AF programs for people with MS was undertaken. The purpose of this phenomenological study was to identify factors that facilitate or impede participation in AF programs by individuals with MS living in Winnipeg. Qualitative data were collected from a total of eight participants through one focus group (n = 7) and one in-depth interview (n = 1). The sample consisted of individuals with MS who were currently participating in AF programming as well as those who were not. Data were audio-recorded and transcribed verbatim, and thematic analysis was completed. Seven themes emerged regarding factors affecting participation in local AF programs. Barriers to participation included inadequate transportation, lack of one-on-one support, environmental inaccessibility, and fears associated with participation in the programs. Facilitators of participation included a knowledgeable instructor and experiencing physical and psychosocial benefits from the program. Information from this study was used locally to advocate for people with MS in order to increase participation in local AF programming. PMID:24453744
Walters, Tomos E; Kalman, Jonathan M; Patel, Sheila K; Mearns, Megan; Velkoska, Elena; Burrell, Louise M
2017-08-01
Angiotensin converting enzyme 2 (ACE2) is an integral membrane protein whose main action is to degrade angiotensin II. Plasma ACE2 activity is increased in various cardiovascular diseases. We aimed to determine the relationship between plasma ACE2 activity and human atrial fibrillation (AF), and in particular its relationship to left atrial (LA) structural remodelling. One hundred and three participants from a tertiary arrhythmia centre, including 58 with paroxysmal AF (PAF), 20 with persistent AF (PersAF), and 25 controls, underwent clinical evaluation, echocardiographic analysis, and measurement of plasma ACE2 activity. A subgroup of 20 participants underwent invasive LA electroanatomic mapping. Plasma ACE2 activity levels were increased in AF [control 13.3 (9.5-22.3) pmol/min/mL; PAF 16.9 (9.7-27.3) pmol/min/mL; PersAF 22.8 (13.7-33.4) pmol/min/mL, P = 0.006]. Elevated plasma ACE2 was associated with older age, male gender, hypertension and vascular disease, elevated left ventricular (LV) mass, impaired LV diastolic function and advanced atrial disease (P < 0.05 for all). Independent predictors of elevated plasma ACE2 activity were AF (P = 0.04) and vascular disease (P < 0.01). There was a significant relationship between elevated ACE2 activity and low mean LA bipolar voltage (adjusted R2 = 0.22, P = 0.03), a high proportion of complex fractionated electrograms (R2 = 0.32, P = 0.009) and a long LA activation time (R2 = 0.20, P = 0.04). Plasma ACE2 activity is elevated in human AF. Both AF and vascular disease predict elevated plasma ACE2 activity, and elevated plasma ACE2 is significantly associated with more advanced LA structural remodelling. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Aleiferis, P. G.; Hardalupas, Y.; Taylor, A. M. K. P.; Ishii, K.; Urata, Y.
2005-11-01
Lean-burn spark-ignition engines exhibit higher efficiency and lower specific emissions in comparison with stoichiometrically charged engines. However, as the air-to-fuel (A/F) ratio of the mixture is made leaner than stoichiometric, cycle-by-cycle variations in the early stages of in-cylinder combustion, and subsequent indicated mean effective pressure (IMEP), become more pronounced and limit the range of lean-burn operation. Viable lean-burn engines promote charge stratification, the mixture near the spark plug being richer than the cylinder volume averaged value. Recent work has shown that cycle-by-cycle variations in the early stages of combustion in a stratified-charge engine can be associated with variations in both the local value of A/F ratio near the spark plug around ignition timing, as well as in the volume averaged value of the A/F ratio. The objective of the current work was to identify possible sources of such variability in A/F ratio by studying the in-cylinder field of fuel-droplet distribution during the early intake stroke. This field was visualised in an optical single-cylinder 4-valve pentroof-type spark-ignition engine by means of laser-sheet illumination in planes parallel to the cylinder head gasket 6 and 10 mm below the spark plug. The engine was run with port-injected isooctane at 1500 rpm with 30% volumetric efficiency and air-to-fuel ratio corresponding to both stoichiometric firing (A/F=15, Φ =1.0) and mixture strength close to the lean limit of stable operation (A/F=22, Φ =0.68). Images of Mie intensity scattered by the cloud of fuel droplets were acquired on a cycle-by-cycle basis. These were studied in order to establish possible correlations between the cyclic variations in size, location and scattered-light intensity of the cloud of droplets with the respective variations in IMEP. Because of the low level of Mie intensity scattered by the droplets and because of problems related to elastic scattering on the walls of the combustion chamber, as well as problems related to engine “rocking” at the operating conditions close to the misfire limit, the acquired images were processed for background subtraction by using a PIV-based data correction algorithm. After this processing, the arrival and leaving timings of fuel droplets into the illuminated plane were found not to vary significantly on a cycle-by-cycle basis but the recorded cycle-by-cycle variations in Mie intensity suggested that the amount of fuel in the cylinder could have been 6 26% greater for the “strong” cycles with IMEP 115% higher than the average IMEP, than the ones imaged for “weak” cycles at less than 85% the average IMEP. This would correspond to a maximum cyclic variability in the in-cylinder equivalence ratio Φ of the order of 0.17.
Xiao, Hanguang; Tan, Isabella; Butlin, Mark; Li, Decai; Avolio, Alberto P
2017-06-01
Experimental investigations have established that the stiffness of large arteries has a dependency on acute heart rate (HR) changes. However, the possible underlying mechanisms inherent in this HR dependency have not been well established. This study aimed to explore a plausible viscoelastic mechanism by which HR exerts an influence on arterial stiffness. A multisegment transmission line model of the human arterial tree incorporating fractional viscoelastic components in each segment was used to investigate the effect of varying fractional order parameter (α) of viscoelasticity on the dependence of aortic arch to femoral artery pulse wave velocity (afPWV) on HR. HR was varied from 60 to 100 beats/min at a fixed mean flow of 100 ml/s. PWV was calculated by intersecting tangent method (afPWV Tan ) and by phase velocity from the transfer function (afPWV TF ) in the time and frequency domain, respectively. PWV was significantly and positively associated with HR for α ≥ 0.6; for α = 0.6, 0.8, and 1, HR-dependent changes in afPWV Tan were 0.01 ± 0.02, 0.07 ± 0.04, and 0.22 ± 0.09 m/s per 5 beats/min; HR-dependent changes in afPWV TF were 0.02 ± 0.01, 0.12 ± 0.00, and 0.34 ± 0.01 m/s per 5 beats/min, respectively. This crosses the range of previous physiological studies where the dependence of PWV on HR was found to be between 0.08 and 0.10 m/s per 5 beats/min. Therefore, viscoelasticity of the arterial wall could contribute to mechanisms through which large artery stiffness changes with changing HR. Physiological studies are required to confirm this mechanism. NEW & NOTEWORTHY This study used a transmission line model to elucidate the role of arterial viscoelasticity in the dependency of pulse wave velocity on heart rate. The model uses fractional viscoelasticity concepts, which provided novel insights into arterial hemodynamics. This study also provides a means of assessing the clinical manifestation of the association of pulse wave velocity and heart rate. Copyright © 2017 the American Physiological Society.
Clarkesmith, Danielle E; Pattison, Helen M; Khaing, Phyo H; Lane, Deirdre A
2017-04-05
Current guidelines recommend oral anticoagulation therapy for patients with atrial fibrillation (AF) with one or more risk factors for stroke; however, anticoagulation control (time in therapeutic range (TTR)) with vitamin K antagonists (VKAs) is dependent on many factors. Educational and behavioural interventions may impact patients' ability to maintain their international normalised ratio (INR) control. This is an updated version of the original review first published in 2013. To evaluate the effects of educational and behavioural interventions for oral anticoagulation therapy (OAT) on TTR in patients with AF. We updated searches from the previous review by searching the Cochrane Central Register of Controlled Trials (CENTRAL) and the Database of Abstracts of Reviews of Effects (DARE) in The Cochrane Library (January 2016, Issue 1), MEDLINE Ovid (1949 to February week 1 2016), EMBASE Classic + EMBASE Ovid (1980 to Week 7 2016), PsycINFO Ovid (1806 to Week 1 February 2016) and CINAHL Plus with Full Text EBSCO (1937 to 16/02/2016). We applied no language restrictions. We included randomised controlled trials evaluating the effect of any educational and behavioural intervention compared with usual care, no intervention, or intervention in combination with other self-management techniques among adults with AF who were eligible for, or currently receiving, OAT. Two of the review authors independently selected studies and extracted data. Risk of bias was assessed using the Cochrane 'Risk of bias' tool. We included outcome data on TTR, decision conflict (patient's uncertainty in making health-related decisions), percentage of INRs in the therapeutic range, major bleeding, stroke and thromboembolic events, patient knowledge, patient satisfaction, quality of life (QoL), beliefs about medication, illness perceptions, and anxiety and depression. We pooled data for three outcomes - TTR, anxiety and depression, and decision conflict - and reported mean differences (MD). Where insufficient data were present to conduct a meta-analysis, we reported effect sizes and confidence intervals (CI) from the included studies. We evaluated the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. Eleven trials with a total of 2246 AF patients (ranging from 14 to 712 by study) were included within the review. Studies included education, decision aids, and self-monitoring plus education interventions. The effect of self-monitoring plus education on TTR was uncertain compared with usual care (MD 6.31, 95% CI -5.63 to 18.25, I 2 = 0%, 2 trials, 69 participants, very low-quality evidence). We found small but positive effects of education on anxiety (MD -0.62, 95% CI -1.21 to -0.04, I 2 = 0%, 2 trials, 587 participants, low-quality evidence) and depression (MD -0.74, 95% CI -1.34 to -0.14, I 2 = 0%, 2 trials, 587 participants, low-quality evidence) compared with usual care. The effect of decision aids on decision conflict favoured usual care (MD -0.1, 95% CI -0.17 to -0.02, I 2 = 0%, 2 trials, 721 participants, low-quality evidence). This review demonstrates that there is insufficient evidence to draw definitive conclusions regarding the impact of educational or behavioural interventions on TTR in AF patients receiving OAT. Thus, more trials are needed to examine the impact of interventions on anticoagulation control in AF patients and the mechanisms by which they are successful. It is also important to explore the psychological implications for patients suffering from this long-term chronic condition.
Impaired endothelial function in lone atrial fibrillation.
Polovina, Marija; Potpara, Tatjana; Giga, Vojislav; Stepanović, Jelena; Ostojić, Miodrag
2013-10-01
Impaired endothelial function has been previously documented in patients with atrial fibrillation (AF) and underlying comorbidities or older patients with idiopathic AF. The aim of this study was to evaluate systemic endothelial function in younger AF patients (less than < 60 years old) with lone AF (that is, without associated cardiopulmonary comorbidities, including arterial hypertension), by comparing brachial artery flow-mediated dilation (FMD) in lone AF patients with FMD of healthy subjects in sinus rhythm. Two groups of participants were prospectively enrolled. The first group comprised of 38 AF patients (the mean age 45 +/- 11 years, 68% male) with persistent (> 7 days) lone AF. The second group comprised of 28 healthy controls in sinus rhythm (the mean age 43 +/- 13, 53% male), matched by age, gender and atherosclerotic risk factors. All the participants underwent physical examination, laboratory analysis [including determination of C-reactive protein (CRP)], standard echocardiography and exercise-stress testing. Brachial artery FMD and endothelium independent dilation (NMD) were assessed with a high-resolution ultrasound probe and arterial diameters taken from 5 consecutive cardiac cycles were averaged for each measurement to accommodate to beat-to-beat flow variations in AF. There were no differences between the 2 groups regarding age, gender and most clinical, laboratory and echocardiographic characteristics (all p > 0.05), apart from the increased heart rate (p = 0.018), body mass index (p = 0.027), CRP levels (p = 0.007) and left atrial anteroposterior dimension (p < 0.001) in AF patients. FMD of AF patients [median value 5.0%, interquartile range (IQR) 2.87%-7.50%] was significantly lower (p < 0.001) than FMD of healthy controls (median value 8.85%, IQR 5.80%-12.50%), whereas there were no differences in median NMD values (p > 0.05). In the multivariate analysis, the independent FMD determinants in our study population were the presence of AF, smoking and total cholesterol levels (all p < 0.001). In patients with AF, the strongest independent FMD determinant was arrhythmia duration (p < 0.001), followed by smoking (p = 0.013) and total cholesterol levels (p = 0.045). Our findings confirm that sustained AF is associated with systemic endothelial dysfunction even in relatively young patients with no cardiovascular disorders or risk factors. AF is an independent contributor to lower FMD and a prolonged arrhythmia duration may confer the risk for more profound endothelial damage.
Embossed Teflon AF Laminate Membrane Microfluidic Diaphragm Valves
NASA Technical Reports Server (NTRS)
Willis, Peter; Hunt, Brian; White,Victor; Grunthaner, Frank
2008-01-01
A microfluidic system has been designed to survive spaceflight and to function autonomously on the Martian surface. It manipulates microscopic quantities of liquid water and performs chemical analyses on these samples to assay for the presence of molecules associated with past or present living processes. This technology lies at the core of the Urey Instrument, which is scheduled for inclusion on the Pasteur Payload of the ESA ExoMars rover mission in 2013. Fabrication processes have been developed to make the microfabricated Teflon-AF microfluidic diaphragm pumps capable of surviving extreme temperature excursions before and after exposure to liquid water. Two glass wafers are etched with features and a continuous Teflon membrane is sandwiched between them (see figure). Single valves are constructed using this geometry. The microfabricated devices are then post processed by heating the assembled device while applying pneumatic pressure to force the Teflon diaphragm against the valve seat while it is softened. After cooling the device, the embossed membrane retains this new shape. This solves previous problems with bubble introduction into the fluid flow where deformations of the membrane at the valve seat occurred during device bonding at elevated temperatures (100-150 C). The use of laminated membranes containing commercial Teflon AF 2400 sheet sandwiched between spun Teflon AF 1600 layers performed best, and were less gas permeable than Teflon AF 1600 membranes on their own. Spinning Teflon AF 1600 solution (6 percent in FLOURINERT(Registered TradeMark) FC40 solvent, 3M Company) at 500 rpm for 1.5 seconds, followed by 1,000 rpm for 3 seconds onto Borofloat glass wafers, results in a 10-micron-thick film of extremely smooth Teflon AF. This spinning process is repeated several times on flat, blank, glass wafers in order to gradually build a thick, smooth membrane. After running this process at least five times, the wafer and Teflon coating are heated under vacuum at 220 C for one hour in order to drive off any residual solvent present in the composite film. After this, a second blank, glass wafer is brought down from above and the stack is held under vacuum at 3 atm mechanical pressure for ten 10 hours.
Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang
2014-02-20
We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Systematic review and meta-analysis. PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion.
Potential use of NOACs in developing countries: pros and cons.
Bista, Durga; Chalmers, Leanne; Bereznicki, Luke; Peterson, Gregory
2014-07-01
Although vitamin K antagonists (VKAs) are effective for long-term thromboprophylaxis in atrial fibrillation (AF), their limitations have led to widespread underutilisation, especially in the developing world. Novel oral anticoagulants (NOACs) have emerged as promising alternatives to VKAs, although there are some particular considerations and challenges to their introduction in developing countries. This review summarises the current state of antithrombotic management of AF in the developing world, explores the early evidence for the NOACs and describes some of the special considerations that must be taken into account when considering the role of the NOACs within developing countries' health care systems. A literature search was conducted via PubMed and Google Scholar to find articles published in English between the years 2000 to 2014. Search terms used were "atrial fibrillation", "oral anticoagulants", "warfarin", "NOACs", "dabigatran", "rivaroxaban", "apixaban", "edoxaban", "time in therapeutic range", "International Normalized Ratio" "cost-effectiveness", "stroke", "adverse-drug reactions" and "drug-drug interactions", together with the individual names of developing countries as listed by the World Bank. We reviewed the results of randomized clinical trials, relevant retrospective and prospective studies, case-studies and review articles. Many developing countries lack or have sporadic data on the quality of AF management, making it difficult to anticipate the potential impact of NOACs in these settings. The utilisation of anticoagulants for AF appears highly variable in developing countries. Given the issues associated with VKA therapy in many developing countries, NOACs offer some potential advantages; however, there is insufficient evidence to advocate the widespread replacement of warfarin at present. VKAs may continue to have a role in selected patients or countries, especially if alternative monitoring strategies can be utilised. The evaluation of the introduction of NOACs should consider safety, budget concerns and the quality of oral anticoagulation care achieved by each country. Prospective registries will be important in developing countries to better elucidate the comparative safety, efficacy and cost-effectiveness of NOACs and VKAs as NOACs are introduced into practice.
GPIM AF-M315E Propulsion System
NASA Technical Reports Server (NTRS)
Spores, Ronald A.; Masse, Robert; Kimbrel, Scott; McLean, Chris
2014-01-01
The NASA Space Technology mission Directorate's (STMD) Green Propellant Infusion Mission (GPIM) Technology Demonstration Mission (TDM) will demonstrate an operational AF-M315E green propellant propulsion system. Aerojet-Rocketdyne is responsible for the development of the propulsion system payload. This paper statuses the propulsion system module development, including thruster design and system design; Initial test results for the 1N engineering model thruster are presented. The culmination of this program will be high-performance, green AF-M315E propulsion system technology at TRL 7+, with components demonstrated to TRL 9, ready for direct infusion to a wide range of applications for the space user community.
França, Renata de Almeida; Esteves, André de Barros Albuquerque; Borges, Cynthia de Moura; Quadros, Kélcia Rosana da Silva; Falcão, Luiz Carlos Nogueira; Caramori, Jacqueline Costa Teixeira; Oliveira, Rodrigo Bueno de
2017-01-01
Chronic kidney disease (CKD) is associated with high morbidity and mortality rates, main causes related with cardiovascular disease (CVD) and bone mineral disorder (CKD-BMD). Uremic toxins, as advanced glycation end products (AGEs), are non-traditional cardiovascular risk factor and play a role on development of CKD-BMD in CKD. The measurement of skin autofluorescence (sAF) is a noninvasive method to assess the level of AGEs in tissue, validated in CKD patients. The aim of this study is analyze AGEs measured by sAF levels (AGEs-sAF) and its relations with CVD and BMD parameters in HD patients. Twenty prevalent HD patients (HD group) and healthy subjects (Control group, n = 24), performed biochemical tests and measurements of anthropometric parameters and AGEs-sAF. In addition, HD group performed measurement of intact parathormone (iPTH), transthoracic echocardiogram and radiographies of pelvis and hands for vascular calcification score. AGEs-sAF levels are elevated both in HD and control subjects ranged according to the age, although higher at HD than control group. Single high-flux HD session does not affect AGEs-sAF levels. AGEs-sAF levels were not related to ventricular mass, interventricular septum or vascular calcification in HD group. AGEs-sAF levels were negatively associated with serum iPTH levels. Our study detected a negative correlation of AGEs-sAF with serum iPTH, suggesting a role of AGEs on the pathophysiology of bone disease in HD prevalent patients. The nature of this relation and the clinical application of this non-invasive methodology for evaluation AGEs deposition must be confirmed and clarified in future studies.
Stulak, John M; Deo, Salil; Schirger, John; Aaronson, Keith D; Park, Soon J; Joyce, Lyle D; Daly, Richard C; Pagani, Francis D
2013-12-01
Because no series has specifically analyzed the impact of preoperative atrial fibrillation (AF) on patients already at higher risk of thromboembolism after implantation of a left ventricular assist device (LVAD), we review our experience with these patients. Between July 2003 and September 2011, 389 patients (308 male) underwent implantation of a continuous flow LVAD at University of Michigan Hospital and Mayo Clinic. Median age at implant was 60 years (range, 18 to 79 years). Preoperative AF was present in 120 patients (31%). Outcomes were analyzed for the association of preoperative AF and postoperative thromboembolic (TE) events defined as stroke, transient ischemic attack, hemolysis, or pump thrombosis. Thromboembolic events occurring within the first 30 days were not counted. One hundred thirty-eight TEs events occurred in 97/389 patients (25%) for an event rate of 0.31 TE events/patient-years of support. Freedom from a TE event in patients with preoperative AF was 62% at 1 year and 46% at 2 years compared with 79% and 72% at 1 and 2 years, respectively, in patients without preoperative AF (p < 0.001). Median survival was 10 months (maximum 7.2 years, total 439 patient-years). Preoperative AF did not decrease late survival at 1 and 2 years after LVAD implant (preop AF: 85% and 70% versus no preop AF: 82% and 70%, respectively; p = 0.55). Patients with preoperative AF have a lower freedom from TE events after LVAD implant. While overall late survival was not significantly reduced in these patients, refinement in anticoagulation strategies after VAD implant may be required. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Active hydrodynamics of synchronization and ordering in moving oscillators
NASA Astrophysics Data System (ADS)
Banerjee, Tirthankar; Basu, Abhik
2017-08-01
The nature of emergent collective behaviors of moving interacting physical agents is a long-standing open issue in physical and biological systems alike. This calls for studies on the control of synchronization and the degree of order in a collection of diffusively moving noisy oscillators. We address this by constructing a generic hydrodynamic theory for active phase fluctuations in a collection of a large number of nearly-phase-coherent moving oscillators in two dimensions. Our theory describes the general situation where phase fluctuations and oscillator mobility mutually affect each other. We show that the interplay between the active effects and the mobility of the oscillators leads to a variety of phenomena, ranging from synchronization with long-range, nearly-long-range, and quasi-long-range orders to instabilities and desynchronization with short-range order of the oscillator phases. We highlight the complex dependences of synchronization on the active effects. These should be testable in wide-ranging systems, e.g., oscillating chemical reactions in the presence of different reaction inhibitors and facilitators, live oriented cytoskeletal extracts, and vertebrate segmentation clocks.
Tischer, Tina S; Schneider, Ralph; Lauschke, Jörg; Diedrich, Doreen; Kundt, Günther; Bänsch, Dietmar
2015-08-01
The HATCH score [hypertension, age > 75 years, previous transient ischemic attack (TIA) or stroke (doubled), chronic obstructive pulmonary disease, heart failure (doubled)] has been established to identify patients who are at risk of developing persistent forms of AF. We investigated whether this score is associated with the prevalence of AF in order to guide diagnostic efforts and therapy. The data of 150,408 consecutive patients who were hospitalized at the University Hospital of Rostock between 2007 and 2012 were analyzed. Factors constituting the HATCH score and the presence of AF were prospectively documented using ICD-10 admission codes. Patients were 67.6 ± 13.6 years of age with a mean HATCH score of 1.48 ± 1.02; 16 % had a history of AF and 4 % suffered a TIA or stroke. The prevalence of AF increased significantly with the HATCH score up to 60.0 % (p < 0.001). In all, 63 % of the patients had a HATCH score of 0 and 1 without any history of stroke. The HATCH score correlates with the occurrence of AF, since the prevalence of AF rises with rising score values. Therefore, the HATCH score may be used to select patients for intensified ECG monitoring. Moreover, the score may also be used for stroke risk assessment, as none of the patients with a low HATCH score suffered a stroke.
Choi, Hyo-In; Ahn, Jung-Min; Kang, Se Hun; Lee, Pil Hyung; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Lee, Cheol Whan; Park, Seong-Wook; Park, Duk-Woo; Park, Seung-Jung
2017-06-12
This study sought to investigate the incidence, management, and clinical relevance of atrial fibrillation (AF) during and after percutaneous coronary intervention (PCI) with drug-eluting stents (DES) and evaluate outcomes of different antithrombotic strategies. Uncertainty exists regarding the optimal antithrombotic strategy in patients with AF who are undergoing PCI with DES. Using a consecutive series of 10,027 patients who underwent DES implantation between 2003 and 2011, we evaluated the overall prevalence and clinical impact of AF. In addition, we compared the efficacy and safety of dual antiplatelet therapy (DAPT) (aspirin plus clopidogrel) and triple therapy (DAPT plus warfarin) among patients with AF. The primary outcome was a composite of cardiovascular death, myocardial infarction, or stroke. Overall, 711 (7.1%) patients had a diagnosis of AF at the index PCI. Patients with AF were older, had more comorbid conditions, and more often had a history of strokes; most patients with AF (88.4%) received DAPT rather than triple therapy (10.5%) at discharge. The rate of primary outcome after PCI during the 6-year follow-up period was significantly higher in patients with AF than in those without AF (22.1% vs. 8.0%; p < 0.001). This trend was consistent for major bleeding (4.5% vs. 1.5%; p < 0.001). After multivariable adjustment, the presence of AF was significantly associated with a higher risk of primary outcome (hazard ratio [HR]: 2.33; 95% confidence interval [CI]: 1.95 to 2.79; p < 0.001) and major bleeding (HR: 2.01; 95% CI: 1.32 to 3.06; p = 0.001). Among patients with AF, adjusted risk for the primary outcome was similar between the DAPT group and the triple therapy group (HR: 1.01; 95% CI: 0.60 to 1.69; p = 0.98), but triple therapy was associated with a significantly higher risk of hemorrhagic stroke (HR: 7.73; 95% CI: 2.14 to 27.91; p = 0.002) and major bleeding (HR: 4.48; 95% CI: 1.81 to 11.08; p = 0.001). Among patients receiving DES implantation, AF was not rare and was associated with increased ischemic and bleeding risk. In patients with AF, triple therapy was not associated with decreased ischemic events but was associated with increased bleeding risk compared to DAPT. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Transition from disordered to long-range ordered nanoparticles on Al2O3/Ni3Al(111)
NASA Astrophysics Data System (ADS)
Alyabyeva, N.; Ouvrard, A.; Zakaria, A.-M.; Charra, F.; Bourguignon, B.
2018-06-01
Application of preparation recipes of the literature failed to produce an ordered array of NPs on our particular Ni3Al sample. This has motivated a systematic survey of Pd NP nucleation as a function of experimental parameters. We have shown that the increase of oxidation temperature during the preparation of Al2O3 ultra-thin film on Ni3Al(111) leads to a transition from disordered to long-range ordered Pd nanoparticle (NP) nucleation. Alumina films were prepared at different temperatures ranging from 990 to 1140 K. Crystallinity, electronic structure of the alumina film and Pd nucleation and growth have been investigated using Low Energy Electron Diffraction and Scanning Tunnelling Microscopy. NP density and long-range order nucleation along the so-called "dot structure" of 4.2 nm periodicity, strongly increase for temperatures higher than a threshold value of 1070 ± 20 K. This transition relies on the alumina film improvement and suggests that the modulation of Pd adsorption energy at nucleation centres which is necessary to nucleate NPs at ordered sites, requires higher preparation temperature. Long-range ordered NPs with a high density were obtained 140 K above reported recipes in the literature. This optimized temperature has been tested on a fresh sample (issued from the same supplier) for which just a few cleanings were enough to obtain long-range ordered NPs. Presumably the variability of the optimal oxidation temperature for our samples with respect to the literature is related to fluctuations of the stoichiometry from sample to sample.
Deeks, Jonathan J; Griffith, Michael; Lip, Gregory YH; Mehta, Samir; Slinn, Gemma; Stanbury, Mary; Steeds, Richard P; Townend, Jonathan N
2017-01-01
Background and objective Atrial fibrillation (AF) is common and causes impaired quality of life, an increased risk of stroke and death as well as frequent hospital admissions. The majority of patients with AF require control of heart rate. In this article, we summarise the limited evidence from clinical trials that guides prescription, and present the rationale and protocol for a new randomised trial. As rate control has not yet been shown to reduce mortality, there is a clear need to compare the impact of therapy on quality of life, cardiac function and exercise capacity. Such a trial should concentrate on the long-term effects of treatment in the largest proportion of patients with AF, those with symptomatic permanent AF, with the aim of improving patient well-being. Design and intervention The RAte control Therapy Evaluation in permanent Atrial Fibrillation (RATE-AF) trial will enrol 160 participants with a prospective, randomised, open-label, blinded end point design comparing initial rate control with digoxin or bisoprolol. This will be the first head-to-head randomised trial of digoxin and beta-blockers in AF. Participants Recruited patients will be aged ≥60 years with permanent AF and symptoms of breathlessness (equivalent to New York Heart Association class II or above), with few exclusion criteria to maximise generalisability to routine clinical practice. Outcome measures The primary outcome is patient-reported quality of life, with secondary outcomes including echocardiographic ventricular function, exercise capacity and biomarkers of cellular and clinical response. Follow-up will occur at 6 and 12 months, with feasibility components to inform the design of a future trial powered to detect a difference in hospital admission. The RATE-AF trial will underpin an integrated approach to management including biomarkers, functions and symptoms that will guide future research into optimal, personalised rate control in patients with AF. Ethics and dissemination East Midlands-Derby Research Ethics Committee (16/EM/0178); peer-reviewed publications. Trial registration Clinicaltrials.gov: NCT02391337; ISRCTN: 95259705. Pre-results. PMID:28729311
Kotecha, Dipak; Calvert, Melanie; Deeks, Jonathan J; Griffith, Michael; Kirchhof, Paulus; Lip, Gregory Yh; Mehta, Samir; Slinn, Gemma; Stanbury, Mary; Steeds, Richard P; Townend, Jonathan N
2017-07-20
Atrial fibrillation (AF) is common and causes impaired quality of life, an increased risk of stroke and death as well as frequent hospital admissions. The majority of patients with AF require control of heart rate. In this article , we summarise the limited evidence from clinical trials that guides prescription, and present the rationale and protocol for a new randomised trial. As rate control has not yet been shown to reduce mortality, there is a clear need to compare the impact of therapy on quality of life, cardiac function and exercise capacity. Such a trial should concentrate on the long-term effects of treatment in the largest proportion of patients with AF, those with symptomatic permanent AF, with the aim of improving patient well-being. The RAte control Therapy Evaluation in permanent Atrial Fibrillation (RATE-AF) trial will enrol 160 participants with a prospective, randomised, open-label, blinded end point design comparing initial rate control with digoxin or bisoprolol. This will be the first head-to-head randomised trial of digoxin and beta-blockers in AF. Recruited patients will be aged ≥60 years with permanent AF and symptoms of breathlessness (equivalent to New York Heart Association class II or above), with few exclusion criteria to maximise generalisability to routine clinical practice. The primary outcome is patient-reported quality of life, with secondary outcomes including echocardiographic ventricular function, exercise capacity and biomarkers of cellular and clinical response. Follow-up will occur at 6 and 12 months, with feasibility components to inform the design of a future trial powered to detect a difference in hospital admission. The RATE-AF trial will underpin an integrated approach to management including biomarkers, functions and symptoms that will guide future research into optimal, personalised rate control in patients with AF. East Midlands-Derby Research Ethics Committee (16/EM/0178); peer-reviewed publications. Clinicaltrials.gov: NCT02391337; ISRCTN: 95259705. Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
NASA Astrophysics Data System (ADS)
Schiebel, Ralf; Waniek, Joanna; Zeltner, Alexandra; Alves, Mário
The Azores Front-Current System, south of the Azores Islands, has been studied in order to reveal the direct impact of an open oceanic thermohaline front on the distribution of the calcareous plankton. Planktic foraminifers, pteropods, heteropods, and coccolithophorids were sampled from the upper 2500 m of the water column during August 1997 and January 1999. In addition, the hydrography was recorded across the frontal jet on combined CTD and XBT transects. In August 1997, a strong seasonal thermocline capped the Azores Front (AF) at about 60-90 m water depth. Below the thermocline a distinct hydrographic front was indicated by temperature and salinity gradients. The central AF was an area of low planktic foraminiferal, gastropod, and coccolithophorid production, and was a faunal barrier for shallow- and deep-dwelling species. Highest numbers of planktic foraminifers, gastropods, and coccolithophores were recorded from above the thermocline north of the AF. The most frequent planktic foraminiferal and pteropod species were Globigerinoides ruber (white) and Limacina inflata, respectively. Below 100 m, planktic foraminifers were most frequent north of the AF and gastropod shells were rare. In particular, the deep-dwelling planktic foraminifer Globorotalia scitula was frequent only at sampling sites north of the AF. In January 1999, the surface water temperature of the Azores Front-Current System was lower and the thermocline was deeper than in August 1997. The planktic foraminiferal standing stock was three times higher than in August 1997, and no water depth related faunal changes occurred. The fauna was dominated by Globorotalia truncatulinoides, and Turborotalita humilis was frequent. During both January and August, the fauna from south of the Azores was different from that to the southeast, recording the occurrence of two different water masses. In this study we present a micropaleontological definition of the AF, in order to provide a paleoceanographic tool that may be used to decipher the late Quaternary current system of the North Atlantic Ocean.
Long-range ordering effect in electrodeposition of zinc and zinc oxide.
Liu, Tao; Wang, Sheng; Shi, Zi-Liang; Ma, Guo-Bin; Wang, Mu; Peng, Ru-Wen; Hao, Xi-Ping; Ming, Nai-Ben
2007-05-01
In this paper, we report the long-range ordering effect observed in the electro-crystallization of Zn and ZnO from an ultrathin aqueous electrolyte layer of ZnSO4 . The deposition branches are regularly angled, covered with random-looking, scalelike crystalline platelets of ZnO. Although the orientation of each crystalline platelet of ZnO appears random, transmission electron microscopy shows that they essentially possess the same crystallographic orientation as the single-crystalline zinc electrodeposit underneath. Based on the experimental observations, we suggest that this unique long-range ordering effect results from an epitaxial nucleation effect in electrocrystallization.
Field dependence of the magnetic correlations of the frustrated magnet SrDy 2 O 4
Gauthier, N.; Fennell, A.; Prévost, B.; ...
2017-05-30
Tmore » he frustrated magnet SrDy 2 O 4 exhibits a field-induced phase with a magnetization plateau at 1 / 3 of the saturation value for magnetic fields applied along the b axis. We report here a neutron scattering study of the nature and symmetry of the magnetic order in this field-induced phase. Below ≈ 0.5 K, there are strong hysteretic effects, and the order is short- or long-ranged for zero-field and field cooling, respectively. We find that the long-range ordered magnetic structure within the zigzag chains is identical to that expected for the one-dimensional axial next-nearest neighbor Ising (ANNNI) model in longitudinal fields. he long-range ordered structure in field contrasts with the short-range order found at zero field, and is most likely reached through enhanced quantum fluctuations with increasing fields.« less
Field dependence of the magnetic correlations of the frustrated magnet SrDy2O4
NASA Astrophysics Data System (ADS)
Gauthier, N.; Fennell, A.; Prévost, B.; Désilets-Benoit, A.; Dabkowska, H. A.; Zaharko, O.; Frontzek, M.; Sibille, R.; Bianchi, A. D.; Kenzelmann, M.
2017-05-01
The frustrated magnet SrDy2O4 exhibits a field-induced phase with a magnetization plateau at 1 /3 of the saturation value for magnetic fields applied along the b axis. We report here a neutron scattering study of the nature and symmetry of the magnetic order in this field-induced phase. Below T ≈0.5 K, there are strong hysteretic effects, and the order is short- or long-ranged for zero-field and field cooling, respectively. We find that the long-range ordered magnetic structure within the zigzag chains is identical to that expected for the one-dimensional axial next-nearest neighbor Ising (ANNNI) model in longitudinal fields. The long-range ordered structure in field contrasts with the short-range order found at zero field, and is probably reached through enhanced quantum fluctuations with increasing fields.
Budzyński, Jacek; Anaszewicz, Marzena
2017-01-01
Atrial fibrillation (AF) and nutrition status abnormalities are two of the most significant epidemics in current health care. The aim of this study was to determine the relationship between the prevalence and outcome of AF, and the parameters of nutritional status among consecutive, real-life patients hospitalised in a university hospital. Analysis of the medical documentation of 4930 consecutive patients aged ≥ 18 years hospitalised for more than one day with diagnoses of cardiovascular disorders. Patients admitted with a diagnosis of AF (n = 512) compared to their counterparts without AF less frequently had an NRS-2002 score ≥ 3, normal range of body mass index (BMI), higher blood haemoglobin, and lower low density lipoprotein cholesterol (LDL-C) concentration. In logistic regression analysis, the risk of a hospitalisation due to AF was negatively related to BMI, NRS-2002 score, and the value of the difference between ideal and actual body mass. Urgent admission and having an NRS-2002 score ≥ 3 remained the only significant variables determining the risk of in-hospital death. Blood concentration of LDL-C and urgent admission were the only significant variables determining risk of 30-day rehospitalisation in the studied population. Inpatients with AF had a lower prevalence of normal body mass. Patients with an AF diagnosis had different risk factors for in-hospital death and 30-day rehospitalisation than their counterparts with diagnosis of cardiovascular diseases but without AF; however, the parameters of nutritional status played an important role in both patient groups. The obesity and cholesterol paradoxes were also observed.
Direct Proof of Endo-Epicardial Asynchrony of the Atrial Wall During Atrial Fibrillation in Humans.
de Groot, Natasja; van der Does, Lisette; Yaksh, Ameeta; Lanters, Eva; Teuwen, Christophe; Knops, Paul; van de Woestijne, Pieter; Bekkers, Jos; Kik, Charles; Bogers, Ad; Allessie, Maurits
2016-05-01
The presence of focal fibrillation waves during atrial fibrillation (AF) can, besides ectopic activity, also be explained by asynchronous activation of the atrial endo- and epicardial layer and transmurally propagating fibrillation waves. To provide direct proof of endo-epicardial asynchrony, we performed simultaneous high-resolution mapping of the right atrial endo- and epicardial wall during AF in humans. Intraoperative mapping of the endo- and epicardial right atrial wall was performed during (induced) AF in 10 patients with AF (paroxysmal: n=3; persistent: n=4; and longstanding persistent: n=3) and 4 patients without a history of AF. A clamp made of 2 rectangular 8×16 electrode arrays (interelectrode distance 2 mm) was inserted into the incision in the right atrial appendage. Recordings of 10 seconds of AF were analyzed to determine the incidence of asynchronous endo-epicardial activation times (≥15 ms) of opposite electrodes. Asynchronous endo-epicardial activation ranged between 0.9 and 55.9% without preference for either side. Focal waves appeared equally frequent at endocardium and epicardium (11% versus 13%; ITALIC! P=0.18). Using strict criteria for breakthrough (presence of an opposite wave within 4 mm and ≤14 ms before the origin of the focal wave), the majority (65%) of all focal fibrillation waves could be attributed to endo-epicardial excitation. We provided the first evidence for asynchronous activation of the endo-epicardial wall during AF in humans. Endo-epicardial asynchrony may play a major role in the pathophysiology of AF and may offer an explanation why in some patients therapy fails. © 2016 American Heart Association, Inc.
Kello, Christopher T; Bella, Simone Dalla; Médé, Butovens; Balasubramaniam, Ramesh
2017-10-01
Humans talk, sing and play music. Some species of birds and whales sing long and complex songs. All these behaviours and sounds exhibit hierarchical structure-syllables and notes are positioned within words and musical phrases, words and motives in sentences and musical phrases, and so on. We developed a new method to measure and compare hierarchical temporal structures in speech, song and music. The method identifies temporal events as peaks in the sound amplitude envelope, and quantifies event clustering across a range of timescales using Allan factor (AF) variance. AF variances were analysed and compared for over 200 different recordings from more than 16 different categories of signals, including recordings of speech in different contexts and languages, musical compositions and performances from different genres. Non-human vocalizations from two bird species and two types of marine mammals were also analysed for comparison. The resulting patterns of AF variance across timescales were distinct to each of four natural categories of complex sound: speech, popular music, classical music and complex animal vocalizations. Comparisons within and across categories indicated that nested clustering in longer timescales was more prominent when prosodic variation was greater, and when sounds came from interactions among individuals, including interactions between speakers, musicians, and even killer whales. Nested clustering also was more prominent for music compared with speech, and reflected beat structure for popular music and self-similarity across timescales for classical music. In summary, hierarchical temporal structures reflect the behavioural and social processes underlying complex vocalizations and musical performances. © 2017 The Author(s).
Experimental Investigation of the Formation of Complex Craters
NASA Astrophysics Data System (ADS)
Martellato, E.; Dörfler, M. A.; Schuster, B.; Wünnemman, K.; Kenkmann, T.
2017-09-01
The formation of complex impact craters is still poorly understood, because standard material models fail to explain the gravity-driven collapse at the observed size-range of a bowl-shaped transient crater into a flat-floored crater structure with a central peak or ring and terraced rim. To explain such a collapse the so-called Acoustic Fluidization (AF) model has been proposed. The AF assumes that heavily fractured target rocks surrounding the transient crater are temporarily softened by an acoustic field in the wake of an expanding shock wave generated upon impact. The AF has been successfully employed in numerous modeling studies of complex crater formation; however, there is no clear relationship between model parameters and observables. In this study, we present preliminary results of laboratory experiments aiming at relating the AF parameters to observables such as the grain size, average wave length of the acoustic field and its decay time τ relative to the crater formation time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andersen, Jacob Lauwring, E-mail: jla@mb.au.dk; Schrøder, Tenna Juul; Christensen, Søren
2014-02-01
The identification of the first small-molecule ligand of the neuronal receptor sortilin and structure determination of the receptor–ligand complex are reported. Sortilin is a type I membrane glycoprotein belonging to the vacuolar protein sorting 10 protein (Vps10p) family of sorting receptors and is most abundantly expressed in the central nervous system. Sortilin has emerged as a key player in the regulation of neuronal viability and has been implicated as a possible therapeutic target in a range of disorders. Here, the identification of AF40431, the first reported small-molecule ligand of sortilin, is reported. Crystals of the sortilin–AF40431 complex were obtained bymore » co-crystallization and the structure of the complex was solved to 2.7 Å resolution. AF40431 is bound in the neurotensin-binding site of sortilin, with the leucine moiety of AF40431 mimicking the binding mode of the C-terminal leucine of neurotensin and the 4-methylumbelliferone moiety of AF40431 forming π-stacking with a phenylalanine.« less
Kahramangil, Bora; Berber, Eren
2017-12-01
Indocyanine green fluorescence (ICGF) and parathyroid autofluorescence (AF) are two new techniques that aid in the identification of parathyroid glands (PG) intraoperatively during thyroidectomy. There is no study comparing the efficacy of these techniques. This was an IRB-approved clinical study comparing the utility of ICGF and AF for identification of PGs during thyroidectomy. Data were collected prospectively. Both techniques were compared to naked eye (NE) for PG detection. Standard statistical methods were used for data analysis. Twenty-two patients in each group underwent a total of 39 total thyroidectomies and 5 thyroid lobectomies. AF and ICGF had similar detection rates for PGs [98% (61 of 62) and 95% (60 of 63) of PGs, respectively; P=0.31]. The location of PGs was suggested before detection with NE more frequently by AF than ICGF [52% (32 of 62) vs. 6% (4 of 63) of PGs; P<0.001]. In 82% (18 of 22) of patients at least one PG was detected by AF before NE, as opposed to 14% (3 of 22) by ICGF (P<0.001). The median (range) number of PGs detected before NE per patient was greater with AF than ICGF [2 (0-3) vs. 0 (0-2)];. Upper PGs were more likely to be detected by AF before recognition with NE than the lower ones (P=0.03). There was no predictive factor for ICGF detection. Postoperative hypocalcemia rates were similar [9% (2 of 22) and 5% (1 of 22) for AF and ICGF, respectively; P>0.99]. To the best of our knowledge, this is the first comparative study between parathyroid AF and ICGF in detection of PGs during thyroidectomy. Our data suggest both techniques have similarly high detection rates and that the main difference lies in the timing of detection. AF more frequently detects PGs before recognition with NE compared to ICGF.
Kahramangil, Bora
2017-01-01
Background Indocyanine green fluorescence (ICGF) and parathyroid autofluorescence (AF) are two new techniques that aid in the identification of parathyroid glands (PG) intraoperatively during thyroidectomy. There is no study comparing the efficacy of these techniques. Methods This was an IRB-approved clinical study comparing the utility of ICGF and AF for identification of PGs during thyroidectomy. Data were collected prospectively. Both techniques were compared to naked eye (NE) for PG detection. Standard statistical methods were used for data analysis. Results Twenty-two patients in each group underwent a total of 39 total thyroidectomies and 5 thyroid lobectomies. AF and ICGF had similar detection rates for PGs [98% (61 of 62) and 95% (60 of 63) of PGs, respectively; P=0.31]. The location of PGs was suggested before detection with NE more frequently by AF than ICGF [52% (32 of 62) vs. 6% (4 of 63) of PGs; P<0.001]. In 82% (18 of 22) of patients at least one PG was detected by AF before NE, as opposed to 14% (3 of 22) by ICGF (P<0.001). The median (range) number of PGs detected before NE per patient was greater with AF than ICGF [2 (0–3) vs. 0 (0–2)];. Upper PGs were more likely to be detected by AF before recognition with NE than the lower ones (P=0.03). There was no predictive factor for ICGF detection. Postoperative hypocalcemia rates were similar [9% (2 of 22) and 5% (1 of 22) for AF and ICGF, respectively; P>0.99]. Conclusions To the best of our knowledge, this is the first comparative study between parathyroid AF and ICGF in detection of PGs during thyroidectomy. Our data suggest both techniques have similarly high detection rates and that the main difference lies in the timing of detection. AF more frequently detects PGs before recognition with NE compared to ICGF. PMID:29302480
Prabhu, Sandeep; Kalla, Manish; Peck, Kah Y; Voskoboinik, Aleksandr; McLellan, Alex J A; Pathik, Bupesh; Nalliah, Chrishan J; Wong, Geoff R; Sugumar, Hariharan; Azzopardi, Sonia M; Lee, Geoffrey; Ling, Liang-Han; Kalman, Jonathan M; Kistler, Peter M
2018-03-02
Pulmonary vein (PV) isolation (PVI) remains the cornerstone of catheter ablation (CA) in persistent atrial fibrillation (AF) (PeAF), although less successful than for paroxysmal AF. Whether rapid or fibrillatory (PV AF) PV firing may identify patients with PeAF more likely to benefit from a PV-based ablation approach is unclear. The purpose of this study was to determine the relationship between the PV cycle length (PVCL) and the PV AF outcome after CA. Before ablation, the multipolar catheter was placed in each PV and the left atrial appendage (LAA) for 100 consecutive cycles. The presence of PV AF, the average PVCL of all 4 veins (PV 4VAverage ), the fastest vein average (PV FVAverage ), the fastest cycle length (PV Fast ) both individually and relative to the average LAA cycle length were calculated. The ablation strategy included PVI and posterior wall isolation with a minimum of 12 months follow-up. A total of 123 patients underwent CA (age 62 ± 9.1 years; CHA 2 DS 2 -VASC score 1.6 ± 1.1; left ventricular ejection fraction 48% ± 13%; left atrial area 31 ± 8.7 cm 2 ; AF duration 16 ± 17 months). PVI was achieved in 100% of patients. Multiprocedure success (MPS; freedom from AF/atrial tachycardia episodes lasting >30 seconds) was achieved in 76% of patients at 24 ± 8.1 months of follow-up after 1.2 ± 0.4 procedures. PV activity was not associated with MPS either absolutely (PV 4VAverage [MPS no vs yes: 178 ± 27 ms vs 177 ± 24 ms; P = .92], PV FVAverage [P = .69], or PV Fast [P = .82]) or as a ratio relative to the LAA cycle length (PV 4VAverage /LAA 1.05 ± 0.11 vs 1.06 ± 0.21; P = .87). The presence of PV AF (31% vs 47%; P = .13) did not predict MPS. The rapidity of PV firing or presence of fibrillation within the PV was not predictive of outcome of CA for PeAF. PV activity does not identify patients most likely to benefit from a PV-based ablation strategy. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Otte, T; Pasch, H; Macko, T; Brüll, R; Stadler, F J; Kaschta, J; Becker, F; Buback, M
2011-07-08
The molar mass distribution (MMD) of synthetic polymers is frequently analyzed by size exclusion chromatography (SEC) coupled to multi angle light scattering (MALS) detection. For ultrahigh molar mass (UHM) or branched polymers this method is not sufficient, because shear degradation and abnormal elution effects falsify the calculated molar mass distribution and information on branching. High temperatures above 130 °C have to be applied for dissolution and separation of semi-crystalline materials like polyolefins which requires special hardware setups. Asymmetrical flow field-flow fractionation (AF4) offers the possibility to overcome some of the main problems of SEC due to the absence of an obstructing porous stationary phase. The SEC-separation mainly depends on the pore size distribution of the used column set. The analyte molecules can enter the pores of the stationary phase in dependence on their hydrodynamic volume. The archived separation is a result of the retention time of the analyte species inside SEC-column which depends on the accessibility of the pores, the residence time inside the pores and the diffusion ability of the analyte molecules. The elution order in SEC is typically from low to high hydrodynamic volume. On the contrary AF4 separates according to the diffusion coefficient of the analyte molecules as long as the chosen conditions support the normal FFF-separation mechanism. The separation takes place in an empty channel and is caused by a cross-flow field perpendicular to the solvent flow. The analyte molecules will arrange in different channel heights depending on the diffusion coefficients. The parabolic-shaped flow profile inside the channel leads to different elution velocities. The species with low hydrodynamic volume will elute first while the species with high hydrodynamic volume elute later. The AF4 can be performed at ambient or high temperature (AT-/HT-AF4). We have analyzed one low molar mass polyethylene sample and a number of narrow distributed polystyrene standards as reference materials with known structure by AT/HT-SEC and AT/HT-AF4. Low density polyethylenes as well as polypropylene and polybutadiene, containing high degrees of branching and high molar masses, have been analyzed with both methods. As in SEC the relationship between the radius of gyration (R(g)) or the molar mass and the elution volume is curved up towards high elution volumes, a correct calculation of the MMD and the molar mass average or branching ratio is not possible using the data from the SEC measurements. In contrast to SEC, AF4 allows the precise determination of the MMD, the molar mass averages as well as the degree of branching because the molar mass vs. elution volume curve and the conformation plot is not falsified in this technique. In addition, higher molar masses can be detected using HT-AF4 due to the absence of significant shear degradation in the channel. As a result the average molar masses obtained from AF4 are higher compared to SEC. The analysis time in AF4 is comparable to that of SEC but the adjustable cross-flow program allows the user to influence the separation efficiency which is not possible in SEC without a costly change of the whole column combination. Copyright © 2011 Elsevier B.V. All rights reserved.
Asghar, Muhammad Asif; Ahmed, Aftab; Iqbal, Javed; Zahir, Erum; Nauman, Hina
2016-07-01
This study aimed to isolate fungal pathogens and to subsequently quantify aflatoxin (AF; B 1 + B 2 + G 1 + G 2 ) contamination in wheat crops grown in Pakistan. Accordingly, a total of 185 wheat samples were collected from different areas of Pakistan and numerous potent fungal pathogens were isolated. AF contamination attributed to the presence of intoxicating fungal pathogens and resulting metabolic activities were quantified using a high performance liquid chromatography-fluorescence detector coupled with postcolumn derivatization. Additionally, the effect of fungal pathogens on seed germination was also examined. The results obtained showed that 50% of tested wheat samples were found to be contaminated with a diverse range of fungal species. The rate of recurrence of fungal pathogens were Aspergillus 31%, Penicillium 9%, Fusarium 8%, Rhizopus 3%, and Alternaria 2%. The presence of Tilletia indica and Claviceps purpurea species was found to be inevident in all tested wheat samples. AFB 1 contamination was detected in 48 (26.0%) samples and AFB 2 in 13 (7.0%) samples. AFG 1 and AFG 2 were not found in any of the tested samples. The contamination range of AFB 1 and AFB 2 was 0.05-4.78 μg/kg and 0.02-0.48 μg/kg, respectively. The total amount of AFs (B 1 + B 2 ) found in 48 (26.0%) samples had a mean level of 0.53 ± 0.40 μg/kg and a contamination range of 0.02-5.26 μg/kg. The overall results showed that in 137 (74.0%) samples, AFs were not found within detectable limits. Furthermore, in 180 (97.2%) samples, AF levels were found to be below the maximum tolerated levels (MTL) recommended by the European Union (4 μg/kg). In five (2.7%) samples, AF contamination was higher than the MTL of the European Union. However, these samples were fit for human consumption with reference to the MTL (20 μg/kg) assigned by the USA (Food and Drug Administration and Food and Agriculture Organization) and Pakistan (Pakistan Standards and Quality Control Authority). Germination rates in healthy and contaminated wheat kernels were 84.6% and 45.2%, respectively. Based on the obtained results, it was concluded that the levels of fungal pathogen and AF contamination in Pakistani-grown wheat are not a potential threat to consumer health. However, control procedures along with a strict monitoring policy are mandatory to further minimize the prevalence of fungal carriers and the potency of AFs in crops cultivated in Pakistan. Copyright © 2016. Published by Elsevier B.V.
Pritt, Jeremy J; Frimpong, Emmanuel A
2010-10-01
Conserving rare species and protecting biodiversity and ecosystem functioning depends on sound information on the nature of rarity. Rarity is multidimensional and has a variety of definitions, which presents the need for a quantitative classification scheme with which to categorize species as rare or common. We constructed such a classification for North American freshwater fishes to better describe rarity in fishes and provide researchers and managers with a tool to streamline conservation efforts. We used data on range extents, habitat specificities, and local population sizes of North American freshwater fishes and a variety of quantitative methods and statistical decision criteria, including quantile regression and a cost-function algorithm to determine thresholds for categorizing a species as rare or common. Species fell into eight groups that conform to an established framework for rarity. Fishes listed by the American Fisheries Society (AFS) as endangered, threatened, or vulnerable were most often rare because their local population sizes were low, ranges were small, and they had specific habitat needs, in that order, whereas unlisted species were most often considered common on the basis of these three factors. Species with large ranges generally had few specific habitat needs, whereas those with small ranges tended to have narrow habitat specificities. We identified 30 species not designated as imperiled by AFS that were rare along all dimensions of rarity and may warrant further study or protection, and we found three designated species that were common along all dimensions and may require a review of their imperilment status. Our approach could be applied to other taxa to aid conservation decisions and serve as a useful tool for future revisions of listings of fish species. © 2010 Society for Conservation Biology.
Attuel, Guillaume; Gerasimova-Chechkina, Evgeniya; Argoul, Francoise; Yahia, Hussein; Arneodo, Alain
2017-01-01
Atrial fibrillation (AF) is a cardiac arrhythmia characterized by rapid and irregular atrial electrical activity with a high clinical impact on stroke incidence. Best available therapeutic strategies combine pharmacological and surgical means. But when successful, they do not always prevent long-term relapses. Initial success becomes all the more tricky to achieve as the arrhythmia maintains itself and the pathology evolves into sustained or chronic AF. This raises the open crucial issue of deciphering the mechanisms that govern the onset of AF as well as its perpetuation. In this study, we develop a wavelet-based multi-scale strategy to analyze the electrical activity of human hearts recorded by catheter electrodes, positioned in the coronary sinus (CS), during episodes of AF. We compute the so-called multifractal spectra using two variants of the wavelet transform modulus maxima method, the moment (partition function) method and the magnitude cumulant method. Application of these methods to long time series recorded in a patient with chronic AF provides quantitative evidence of the multifractal intermittent nature of the electric energy of passing cardiac impulses at low frequencies, i.e., for times (≳0.5 s) longer than the mean interbeat (≃ 10 -1 s). We also report the results of a two-point magnitude correlation analysis which infers the absence of a multiplicative time-scale structure underlying multifractal scaling. The electric energy dynamics looks like a "multifractal white noise" with quadratic (log-normal) multifractal spectra. These observations challenge concepts of functional reentrant circuits in mechanistic theories of AF, still leaving open the role of the autonomic nervous system (ANS). A transition is indeed observed in the computed multifractal spectra which group according to two distinct areas, consistently with the anatomical substrate binding to the CS, namely the left atrial posterior wall, and the ligament of Marshall which is innervated by the ANS. In a companion paper (II. Modeling), we propose a mathematical model of a denervated heart where the kinetics of gap junction conductance alone induces a desynchronization of the myocardial excitable cells, accounting for the multifractal spectra found experimentally in the left atrial posterior wall area.
Attuel, Guillaume; Gerasimova-Chechkina, Evgeniya; Argoul, Francoise; Yahia, Hussein; Arneodo, Alain
2018-01-01
Atrial fibrillation (AF) is a cardiac arrhythmia characterized by rapid and irregular atrial electrical activity with a high clinical impact on stroke incidence. Best available therapeutic strategies combine pharmacological and surgical means. But when successful, they do not always prevent long-term relapses. Initial success becomes all the more tricky to achieve as the arrhythmia maintains itself and the pathology evolves into sustained or chronic AF. This raises the open crucial issue of deciphering the mechanisms that govern the onset of AF as well as its perpetuation. In this study, we develop a wavelet-based multi-scale strategy to analyze the electrical activity of human hearts recorded by catheter electrodes, positioned in the coronary sinus (CS), during episodes of AF. We compute the so-called multifractal spectra using two variants of the wavelet transform modulus maxima method, the moment (partition function) method and the magnitude cumulant method. Application of these methods to long time series recorded in a patient with chronic AF provides quantitative evidence of the multifractal intermittent nature of the electric energy of passing cardiac impulses at low frequencies, i.e., for times (≳0.5 s) longer than the mean interbeat (≃ 10−1 s). We also report the results of a two-point magnitude correlation analysis which infers the absence of a multiplicative time-scale structure underlying multifractal scaling. The electric energy dynamics looks like a “multifractal white noise” with quadratic (log-normal) multifractal spectra. These observations challenge concepts of functional reentrant circuits in mechanistic theories of AF, still leaving open the role of the autonomic nervous system (ANS). A transition is indeed observed in the computed multifractal spectra which group according to two distinct areas, consistently with the anatomical substrate binding to the CS, namely the left atrial posterior wall, and the ligament of Marshall which is innervated by the ANS. In a companion paper (II. Modeling), we propose a mathematical model of a denervated heart where the kinetics of gap junction conductance alone induces a desynchronization of the myocardial excitable cells, accounting for the multifractal spectra found experimentally in the left atrial posterior wall area. PMID:29632492
Altoè, Alessandro; Pulkki, Ville; Verhulst, Sarah
2018-07-01
The basolateral membrane of the mammalian inner hair cell (IHC) expresses large voltage and Ca 2+ gated outward K + currents. To quantify how the voltage-dependent activation of the K + channels affects the functionality of the auditory nerve innervating the IHC, this study adopts a model of mechanical-to-neural transduction in which the basolateral K + conductances of the IHC can be made voltage-dependent or not. The model shows that the voltage-dependent activation of the K + channels (i) enhances the phase-locking properties of the auditory fiber (AF) responses; (ii) enables the auditory nerve to encode a large dynamic range of sound levels; (iii) enables the AF responses to synchronize precisely with the envelope of amplitude modulated stimuli; and (iv), is responsible for the steep offset responses of the AFs. These results suggest that the basolateral K + channels play a major role in determining the well-known response properties of the AFs and challenge the classical view that describes the IHC membrane as an electrical low-pass filter. In contrast to previous models of the IHC-AF complex, this study ascribes many of the AF response properties to fairly basic mechanisms in the IHC membrane rather than to complex mechanisms in the synapse. Copyright © 2018 Elsevier B.V. All rights reserved.
Yang, Baode; Li, Chenxing; Sun, Junyi; Wang, Xinghui; Liu, Xinling; Yang, Chun; Chen, Lina; Zhou, Jun; Hu, Hao
2017-05-01
Excessive consumption of alcohol is a well-established risk factor of atrial fibrillation (AF). However, the effects of moderate alcohol drinking remain to be elucidated. This study was designed to determine the effects of moderate ethanol ingestion on atrial fibrillation and the electrophysiological mechanisms. In acetylcholine-induced canine and mouse AF models, the moderate ethanol prevented the generation and persistence of AF through prolonging the latent period of AF and shortening the duration of AF. The action potential duration (APD) was remarkably prolonged under the concentration range of 12.5-50.0mM ethanol in guinea pig atrial myocytes. Ultra-rapid delayed rectified potassium currents (I Kv1.5 ) were markedly inhibited by 12.5-50.0mM ethanol in a concentration-dependent manner. Ethanol with 50.0mM could inhibit rapid delayed rectifier potassium currents (I hERG ). Ethanol under 6.25-50.0mM did not affect on inward rectifier potassium currents (I Kir2.1 ). Collectively, the present study provided an evidence that moderate ethanol intake can prolong the APD of atrial myocytes by inhibition of I Kv1.5 and I hERG , which contributed to preventing the development and duration of AF. Copyright © 2017 Elsevier Inc. All rights reserved.
Charts for Helicopter-Performance Estimation
1945-08-01
tilerelatlons among the design parameters. Tinerasults should theref~r~ he af practical assistance in comparative performance studies. The accuracy with...page facing the figure, Ihxnerlcal appllcatton.- In order to calculate the maximum value af the rata-of-climb parameter” Ym It is necessary first to find...values of A\\~ and ~ when Czt ~ as 01, snd k have been selected. For Khe values c~ = 1.5 snd a = 6, curves 2 t of uYt Qgatnst h\\v for several values of
Liu, Guang-Hua; You, Wen-Long; Li, Wei; Su, Gang
2015-04-29
Quantum phase transitions (QPTs) and the ground-state phase diagram of the spin-1/2 Heisenberg-Ising alternating chain (HIAC) with uniform Dzyaloshinskii-Moriya (DM) interaction are investigated by a matrix-product-state (MPS) method. By calculating the odd- and even-string order parameters, we recognize two kinds of Haldane phases, i.e. the odd- and even-Haldane phases. Furthermore, doubly degenerate entanglement spectra on odd and even bonds are observed in odd- and even-Haldane phases, respectively. A rich phase diagram including four different phases, i.e. an antiferromagnetic (AF), AF stripe, odd- and even-Haldane phases, is obtained. These phases are found to be separated by continuous QPTs: the topological QPT between the odd- and even-Haldane phases is verified to be continuous and corresponds to conformal field theory with central charge c = 1; while the rest of the phase transitions in the phase diagram are found to be c = 1/2. We also revisit, with our MPS method, the exactly solvable case of HIAC model with DM interactions only on odd bonds and find that the even-Haldane phase disappears, but the other three phases, i.e. the AF, AF stripe and odd-Haldane phases, still remain in the phase diagram. We exhibit the evolution of the even-Haldane phase by tuning the DM interactions on the even bonds gradually.
Experimental investigation of the ordering pathway in a Ni-33 at.%Cr alloy
Gwalani, B.; Alam, T.; Miller, C.; ...
2016-06-17
The present study involves a detailed experimental investigation of the concurrent compositional clustering and long-range ordering tendencies in a Ni-33 at.%Cr alloy, carried out by coupling synchrotron-based X-ray diffraction (XRD), transmission electron microscopy (TEM), and atom probe tomography (APT). Synchrotron-based XRD results clearly exhibited progressively increasing lattice contraction in the matrix with increasing isothermal aging time, at 475 degrees C, eventually leading to the development of long-range ordering (LRO) of the Pt2Mo-type. Detailed TEM and APT investigations revealed that this LRO in the matrix is manifested in the form of nanometer-scale ordered domains, and the spatial distribution, size, morphology andmore » compositional evolution of these domains have been carefully investigated. Here, the APT results also revealed the early stages of compositional clustering prior to the onset of long-range ordering in this alloy and such compositional clustering can potentially be correlated to the lattice contraction and previously proposed short-range ordering tendencies.« less
Generalized Lee-Wick formulation from higher derivative field theories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, Inyong; Kwon, O-Kab; Department of Physics, BK21 Physics Research Division, Institute of Basic Science, Sungkyunkwan University, Suwon 440-746
2010-07-15
We study a higher derivative (HD) field theory with an arbitrary order of derivative for a real scalar field. The degree of freedom for the HD field can be converted to multiple fields with canonical kinetic terms up to the overall sign. The Lagrangian describing the dynamics of the multiple fields is known as the Lee-Wick (LW) form. The first step to obtain the LW form for a given HD Lagrangian is to find an auxiliary field (AF) Lagrangian which is equivalent to the original HD Lagrangian up to the quantum level. Until now, the AF Lagrangian has been studiedmore » only for N=2 and 3 cases, where N is the number of poles of the two-point function of the HD scalar field. We construct the AF Lagrangian for arbitrary N. By the linear combinations of AF fields, we also obtain the corresponding LW form. We find the explicit mapping matrices among the HD fields, the AF fields, and the LW fields. As an exercise of our construction, we calculate the relations among parameters and mapping matrices for N=2, 3, and 4 cases.« less
Carbonyl-based blue autofluorescence of proteins and amino acids
Niyangoda, Chamani; Miti, Tatiana; Breydo, Leonid; Uversky, Vladimir
2017-01-01
Intrinsic protein fluorescence is inextricably linked to the near-UV autofluorescence of aromatic amino acids. Here we show that a novel deep-blue autofluorescence (dbAF), previously thought to emerge as a result of protein aggregation, is present at the level of monomeric proteins and even poly- and single amino acids. Just as its aggregation-related counterpart, this autofluorescence does not depend on aromatic residues, can be excited at the long wavelength edge of the UV and emits in the deep blue. Differences in dbAF excitation and emission peaks and intensities from proteins and single amino acids upon changes in solution conditions suggest dbAF’s sensitivity to both the chemical identity and solution environment of amino acids. Autofluorescence comparable to dbAF is emitted by carbonyl-containing organic solvents, but not those lacking the carbonyl group. This implicates the carbonyl double bonds as the likely source for the autofluorescence in all these compounds. Using beta-lactoglobulin and proline, we have measured the molar extinction coefficients and quantum yields for dbAF in the monomeric state. To establish its potential utility in monitoring protein biophysics, we show that dbAF emission undergoes a red-shift comparable in magnitude to tryptophan upon thermal denaturation of lysozyme, and that it is sensitive to quenching by acrylamide. Carbonyl dbAF therefore provides a previously neglected intrinsic optical probe for investigating the structure and dynamics of amino acids, proteins and, by extension, DNA and RNA. PMID:28542206
Carryover of aflatoxins from feed to lambari fish (Astyanax altiparanae) tissues.
Michelin, E C; Massocco, M M; Godoy, S H S; Baldin, J C; Yasui, G S; Lima, C G; Rottinghaus, G E; Sousa, R L M; Fernandes, A M
2017-02-01
The aim of this study was to verify the carryover of aflatoxin B 1 from feed to lambari fish. Aflatoxins (AF) were incorporated into feed, checking the levels by HPLC. Treatments were: Control, feed without toxin; A, feed + 10 µg AFB 1 kg - 1 ; B, feed + 20 µg AFB 1 kg - 1 ; and C, feed + 50 µg AFB 1 kg - 1 . Juveniles of lambari fish were placed in 12 aquariums at a density of 50 fish/m 2 . Fish were fed twice a day with extruded feed, at 5% of animal biomass. The unit sample was constituted by a pool of 10 fish. AFs B 1 , B 2 , G 1 , G 2 and M 1 were quantified by HPLC in fish muscle and liver after 30, 60, 90 and 120 days of experiment. There was accumulation of AFs is fish liver and muscle, mainly after 90 days. Fish from treatment C had higher levels of AFB 1 in muscle when compared with the others, and AFB 1 in muscle at 120 days was similar to the levels in feed. Therefore, when lambari fish is exposed on a daily and long-term basis to AFs in feed, the regulation limits for AFs in animal feed do not guarantee safety for consumers.
Positional short-range order in the nematic phase of n BABAs
NASA Astrophysics Data System (ADS)
Usha Deniz, K.; Pepy, G.; Parette, G.; Keller, P.
1991-10-01
The positional short-range order, SRO ⊥, perpendicular to the nematic director n̂ has been studied in the fibre-type nematics, nBABAs, by neutron diffraction. SRO ⊥ is found to be dependent on other types of nematic short-range order but not on the orientational long-range order.
Vallejo-Ramos, Mariana; Moreno-Calles, Ana I; Casas, Alejandro
2016-07-22
Transformation of natural ecosystems into intensive agriculture is a main factor causing biodiversity loss worldwide. Agroforestry systems (AFS) may maintain biodiversity, ecosystem benefits and human wellbeing, they have therefore high potential for concealing production and conservation. However, promotion of intensive agriculture and disparagement of TEK endanger their permanence. A high diversity of AFS still exist in the world and their potentialities vary with the socio-ecological contexts. We analysed AFS in tropical, temperate, and arid environments, of the Tehuacan Valley, Mexico, to investigate how their capacity varies to conserve biodiversity and role of TEK influencing differences in those contexts. We hypothesized that biodiversity in AFS is related to that of forests types associated and the vigour of TEK and management. We conducted studies in a matrix of environments and human cultures in the Tehuacán Valley. In addition, we reviewed, systematized and compared information from other regions of Mexico and the world with comparable socio-ecological contexts in order to explore possible general patterns. Our study found from 26 % to nearly 90 % of wild plants species richness conserved in AFS, the decreasing proportion mainly associated to pressures for intensifying agricultural production and abandoning traditional techniques. Native species richness preserved in AFS is influenced by richness existing in the associated forests, but the main driver is how people preserve benefits of components and functions of ecosystems. Elements of modern agricultural production may coexist with traditional management patterns, but imposition of modern models may break possible balances. TEK influences decisions on what and how modern techniques may be advantageous for preserving biodiversity, ecosystem integrity in AFS and people's wellbeing. TEK, agroecology and other sciences may interact for maintaining and improving traditional AFS to increase biodiversity and ecosystem integrity while improving quality of life of people managing the AFS.
Ma, Xinbo; Wong, Pak Kin; Zhao, Jing; Xie, Zhengchao
2016-01-01
Active front steering (AFS) is an emerging technology to improve the vehicle cornering stability by introducing an additional small steering angle to the driver’s input. This paper proposes an AFS system with a variable gear ratio steering (VGRS) actuator which is controlled by using the sliding mode control (SMC) strategy to improve the cornering stability of vehicles. In the design of an AFS system, different sensors are considered to measure the vehicle state, and the mechanism of the AFS system is also modelled in detail. Moreover, in order to improve the cornering stability of vehicles, two dependent objectives, namely sideslip angle and yaw rate, are considered together in the design of SMC strategy. By evaluating the cornering performance, Sine with Dwell and accident avoidance tests are conducted, and the simulation results indicate that the proposed SMC strategy is capable of improving the cornering stability of vehicles in practice. PMID:28036037
Fratino, L.; Charlebois, M.; Sémon, P.; ...
2017-12-19
Recent quantum-gas microscopy of ultracold atoms and scanning tunneling microscopy of the cuprates reveal new detailed information about doped Mott antiferromagnets, which can be compared with calculations. Using cellular dynamical mean-field theory, we map out the antiferromagnetic (AF) phase of the two-dimensional Hubbard model as a function of interaction strength U, hole doping δ, and temperature T . The Néel phase boundary is nonmonotonic as a function of U and δ. Frustration induced by second-neighbor hopping reduces Néel order more effectively at small U. The doped AF is stabilized at large U by kinetic energy and at small U bymore » potential energy. The transition between the AF insulator and the doped metallic AF is continuous. At large U, we find in-gap states similar to those observed in scanning tunneling microscopy. Finally, we predict that, contrary to the Hubbard bands, these states are only slightly spin polarized.« less
NASA Astrophysics Data System (ADS)
Fratino, L.; Charlebois, M.; Sémon, P.; Sordi, G.; Tremblay, A.-M. S.
2017-12-01
Recent quantum-gas microscopy of ultracold atoms and scanning tunneling microscopy of the cuprates reveal new detailed information about doped Mott antiferromagnets, which can be compared with calculations. Using cellular dynamical mean-field theory, we map out the antiferromagnetic (AF) phase of the two-dimensional Hubbard model as a function of interaction strength U , hole doping δ , and temperature T . The Néel phase boundary is nonmonotonic as a function of U and δ . Frustration induced by second-neighbor hopping reduces Néel order more effectively at small U . The doped AF is stabilized at large U by kinetic energy and at small U by potential energy. The transition between the AF insulator and the doped metallic AF is continuous. At large U , we find in-gap states similar to those observed in scanning tunneling microscopy. We predict that, contrary to the Hubbard bands, these states are only slightly spin polarized.
Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang
2014-01-01
Objectives We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Design Systematic review and meta-analysis. Data sources PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. Study eligibility criteria This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. Primary and secondary outcome measures We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. Results We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). Conclusions hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion. PMID:24556243
Yuan, Shiwen; Holmqvist, Fredrik; Kongstad, Ole; Jensen, Steen M; Wang, Lingwei; Ljungström, Erik; Hertervig, Eva; Borgquist, Rasmus
2017-12-01
Comparisons between remote magnetic (RMN) and manual catheter navigation for atrial fibrillation (AF) ablation have earlier been reported with controversial results. However, these reports were based on earlier generations of the RMN system. To evaluate the outcomes of the most current RMN system for AF ablation in a larger patient population with longer follow-up time, 112 patients with AF (78 paroxysmal, 34 persistent) who underwent AF ablation utilizing RMN (RMN group) were compared to 102 AF ablation patients (72 paroxysmal, 30 persistent) utilizing manual technique (Manual group). The RMN group was associated with significantly shorter fluoroscopy time (10.4 ± 6.4 vs. 16.3 ± 10.9 min, p < .001) but used more RF energy (64.1 ± 19.4KJ vs. 54.3 ± 24.1 KJ, p < .05), while total procedure time showed no significant difference (201 ± 35 vs. 196 ± 44 min, NS). After 39 ± 9/44 ± 10 months of follow-up, AF-free rates at 1year, 2 years and 3.5 years post ablation were 63%, 46% and 42% in the RMN group vs. 60%, 32% and 30% (survival analysis p < .05) in the Manual group, whereas clinically effective rates were 82%, 73% and 70% for the former vs. 70%, 56% and 49% for the latter (survival analysis p < .005). Differing from previous reports, our data from a larger patient population and longer follow-up time demonstrates that compared to manual technique, the most current RMN technique is associated with better procedural and clinical outcomes for AF ablation.
Adragão, Pedro Pulido; Cavaco, Diogo; Ferreira, António Miguel; Costa, Francisco Moscoso; Parreira, Leonor; Carmo, Pedro; Morgado, Francisco Bello; Santos, Katya Reis; Santos, Pedro Galvão; Carvalho, Maria Salomé; Durazzo, Anai; Marques, Hugo; Gonçalves, Pedro Araújo; Raposo, Luís; Mendes, Miguel
2016-03-01
Whether or not the potential advantages of using a magnetic navigation system (MNS) translate into improved outcomes in patients undergoing atrial fibrillation (AF) ablation is a question that remains unanswered. In this observational registry study, we used propensity-score matching to compare the outcomes of patients with symptomatic drug-refractory AF who underwent catheter ablation using MNS with the outcomes of those who underwent catheter ablation using conventional manual navigation. Among 1,035 eligible patients, 287 patients in each group had similar propensity scores and were included in the analysis. The primary efficacy outcome was the rate of AF relapse after a 3-month blanking period. At a mean follow-up of 2.6 ± 1.5 years, AF ablation with MNS was associated with a similar risk of AF relapse as compared with manual navigation (18.4% per year and 22.3% per year, respectively; hazard ratio 0.81, 95% CI 0.63-1.05; P = 0.108). Major complications occurred in two patients (0.7%) using MNS, and in six patients (2.1%) undergoing manually navigated ablation (P = 0.286). Fluoroscopy times were 21 ± 10 minutes in the manual navigation group, and 12 ± 9 minutes in the MNS group (P < 0.001), whereas total procedure times were 152 ± 52 minutes and 213 ± 58 minutes, respectively (P < 0.001). In this propensity-score matched comparison, magnetic navigation and conventional manual AF ablations seem to have similar relapse rates and a similar risk of complications. AF ablations with magnetic navigation take longer to perform but expose patients to significantly shorter fluoroscopy times. © 2015 Wiley Periodicals, Inc.
A KCNQ1 Mutation Causes a High Penetrance for Familial Atrial Fibrillation
Bartos, Daniel C.; Anderson, Jeffrey B.; Bastiaenen, Rachel; Johnson, Jonathan N.; Gollob, Michael H; Tester, David J.; Burgess, Don E.; Homfray, Tessa; Behr, Elijah R.; Ackerman, Michael J.; Guicheney, Pascale; Delisle, Brian P.
2012-01-01
Background Atrial fibrillation (AF) is the most common cardiac arrhythmia, and its incidence is expected to grow. A genetic predisposition for AF has long been recognized, but its manifestation in these patients likely involves a combination of rare and common genetic variants. Identifying genetic variants that associate with a high penetrance for AF would represent a significant breakthrough for understanding the mechanisms that associate with disease. Method and Results Candidate gene sequencing in five unrelated families with familial AF identified the KCNQ1 missense mutation p.Arg231His (R231H). In addition to AF, several of the family members have abnormal QTc intervals, syncope, or experienced sudden cardiac arrest or death. KCNQ1 encodes the voltage-gated K+ channel that conducts the slowly activating delayed rectifier K+ current in the heart. Functional and computational analyses suggested that R231H increases KCNQ1 current (IKCNQ1) to shorten the atrial action potential (AP) duration. R231H is predicted to minimally affect ventricular excitability, but it prevented the increase in IKCNQ1 following PKA activation. The unique properties of R231H appeared to be caused by a loss in voltage-dependent gating. Conclusions The R231H variant causes a high penetrance for interfamilial early-onset AF. Our study indicates R231H likely shortens atrial refractoriness to promote a substrate for reentry. Additionally, R231H might cause abnormal ventricular repolarization by disrupting PKA activation of IKCNQ1. We conclude genetic variants, which increase IKs during the atrial AP, decrease the atrial AP duration, and/or shorten atrial refractoriness, present a high risk for interfamilial AF. PMID:23350853
Uhm, Jae-Sun; Won, Hoyoun; Joung, Boyoung; Nam, Gi-Byoung; Choi, Kee-Joon; Lee, Moon-Hyoung; Kim, You-Ho; Pak, Hui-Nam
2014-09-01
Although current guidelines recommend continuing the same antithrombotic strategy regardless of rhythm control after radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF), anticoagulation has a risk of major bleeding. We evaluated the safety of switching warfarin to aspirin in patients with successful AF ablation. Among 721 patients who underwent RFCA of AF, 608 patients (age, 57.3±10.9 years; 77.0% male, 75.5% paroxysmal AF) who had no evidence of AF recurrence at 3 months post-RFCA were included. We compared the thromboembolic and hemorrhagic events in patients for whom warfarin was switched to aspirin (ASA group; n=296) and patients who were kept on warfarin therapy (W group; n=312). There were no significant differences in CHA₂DS₂-VASc or HAS-BLED scores between the groups. In 30 patients in the ASA group and 37 patients in W group, AF recurred and warfarin was restarted or maintained during the 18.0±12.2 months of follow-up. There were no significant differences in thromboembolic (0.3% vs. 1.0%, p=0.342) and major bleeding incidences (0.7% vs. 0.6%, p=0.958) between ASA and W groups during the follow-up period. In the 259 patients with a CHA₂DS₂-VASc score≥2, there were no significant differences in thromboembolism (0.8% and 2.2%, p=0.380) or major bleeding incidences (0.8% and 1.4%, p=0.640) between ASA and W groups. Switching warfarin to aspirin 3 months after successful RFCA of AF could be as safe and efficacious as long-term anticoagulation even in patients with CHA₂DS₂-VASc score≥2. However, strict rhythm monitoring cannot be overemphasized.
Action of nitrofurans on E. coli: mutation and induction and repair of daughter-strand gaps in DNA.
Lu, C; McCalla, D R; Bryant, D W
1979-06-01
The antibacterial and mutagenic potency of 9 nitrofurans in "treat and plate" experiments varied over almost 5 orders of magnitude. The relative toxicities were as follows: FANFT greater than AF2 greater than ANFT greather than furazolidone greater than furagin greater than nitrofurantoin greater than nitrofurazone greater than methylnitrofuroate greater than nitrofuroic acid. In general, mutagenic activity paralleled toxicity. The compounds at concentrations corresponding to their LD50's, induced mutations at frequencies which ranged from 2.5/10(6) survivors for FANFT to 130/10(6) survivors for furagin (NF416). The observed differences in antibacterial and mutagenic activity are unlikely to be due to lack of activation of the weaker agents since the two most potent agents were reduced somewhat more slowly than many of the less active agents. The relative sensitivities to the antibacterial effects of AF2 of strains WP2, WP2 uvrA, CM561 (lexA) and CM571 (recA) were 1 : 1.6 : 3 : 7 and to nitrofurazone 1 : 1 : 25 : 50. The wvrA strain was 6--7-fold more mutable with both these agents than was WP2. No increase over the spontaneous mutation frequency was observed when recA or lexA strains were exposed to either AF2 or nitrofurazone in these experiments. When wild-type of wvrA bacteria containing nitrofuran-induced lesions replicated their DNA in drug-free medium in the presence of [3H]thymidine for 5 min, the label was found in low molecular weight DNA indicating that daughter-strand gaps were formed. During subsequent incubation in nonradioactive medium the molecular weight of the DNA increased to the control value. A recA strain (which was very sensitive to the lethal effects of AF2 and nitrofurazone) lacked the ability to repair daughter-strand gaps caused by nitrofuran-induced lesions.
Collins, Michelle; Long, Rita; Page, Anthony; Popay, Jennie; Lobban, Fiona
2018-04-25
We assess the utility of the Public Involvement Impact Assessment Framework (PiiAF) as a resource to support research teams in assessing the impact of Public Involvement across diverse research and public involvement (PI) contexts. PiiAF was developed in response to a well-documented growth in Public Involvement in health research in the United Kingdom that demands a more sophisticated evidence base to demonstrate its impact. We used a reflective case study approach drawing on contemporaneous meeting notes, PiiAF website resources and retrospective reflections to describe how PiiAF helped us to develop an impact assessment plan of the PI in a university-based mental health research centre. We consider key aspects of our experiences of using PiiAF as a tool to help us design an impact assessment of PI, interpret these experiences with reference to relevant theory and research and share insights that may be useful to other teams considering using PiiAF. These insights include understanding the commitment of time and effort required to develop effective PI impact assessment plans; the flexibility of PiiAF and its ability to be used in a range of research and PI contexts; and the advantages of involving all stakeholders (including the public) in the development of an PI assessment plan. © 2018 The Authors. Health Expectations published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Baode; Li, Chenxing
Excessive consumption of alcohol is a well-established risk factor of atrial fibrillation (AF). However, the effects of moderate alcohol drinking remain to be elucidated. This study was designed to determine the effects of moderate ethanol ingestion on atrial fibrillation and the electrophysiological mechanisms. In acetylcholine-induced canine and mouse AF models, the moderate ethanol prevented the generation and persistence of AF through prolonging the latent period of AF and shortening the duration of AF. The action potential duration (APD) was remarkably prolonged under the concentration range of 12.5–50.0 mM ethanol in guinea pig atrial myocytes. Ultra-rapid delayed rectified potassium currents (I{submore » Kv1.5}) were markedly inhibited by 12.5–50.0 mM ethanol in a concentration-dependent manner. Ethanol with 50.0 mM could inhibit rapid delayed rectifier potassium currents (I{sub hERG}). Ethanol under 6.25–50.0 mM did not affect on inward rectifier potassium currents (I{sub Kir2.1}). Collectively, the present study provided an evidence that moderate ethanol intake can prolong the APD of atrial myocytes by inhibition of I{sub Kv1.5} and I{sub hERG}, which contributed to preventing the development and duration of AF. - Highlights: • Moderate ethanol prevented the development of AF in animal models. • Moderate ethanol prolonged APD in guinea pig atrial myocytes. • Moderate ethanol inhibited Kv1.5 currents.« less
Refusing to Twist: Demonstration of a Line Hexatic Phase in DNA Liquid Crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strey, H. H.; NICHD/LPSB, National Institutes of Health, Building 12A/2041, Bethesda, Maryland 20892-5626; Wang, J.
2000-04-03
We report conclusive high resolution small angle x-ray scattering evidence that long DNA fragments form an untwisted line hexatic phase between the cholesteric and the crystalline phases. The line hexatic phase is a liquid-crystalline phase with long-range hexagonal bond-orientational order, long-range nematic order, but liquidlike, i.e., short-range, positional order. So far, it has not been seen in any other three dimensional system. By line-shape analysis of x-ray scattering data we found that positional order decreases when the line hexatic phase is compressed. We suggest that such anomalous behavior is a result of the chiral nature of DNA molecules. (c) 2000more » The American Physical Society.« less
Damage to cochlear efferents following AF64A intoxication.
Smith, D W; Mount, R J
1993-07-01
Damage to cochlear efferents in chinchillas was assessed using transmission electron microscopy following unilateral treatment with the cholinotoxin ethylcholine mustard aziridinium ion (AF64A). AF64A was diluted in artificial perilymph to concentrations ranging from 0.5 to 100 microM. Survival times ranged from 1 to 12 weeks. At concentrations above 10 microM, widespread damage was noted to efferent fibers within the inner spiral bundle (ISB), tunnel spiral bundle (TSB), tunnel radial fibers (TRF) and efferent terminals at the base of OHCs. This damage included degeneration of fibers and terminals, delamination of mitochondria, vacuolization, and loss of cell membrane. However, at high concentrations, non-specific damage was also noted as thinnings or discontinuities of the membrane of OHCs and afferent fibers. At concentrations between 3 and 10 microM, selective damage was observed to efferent fibers within the ISB, TSB, TRF, and to terminals at the base of the OHCs, with all other structures appearing normal. At concentrations of 0.5 and 1 microM, damage was limited to efferent fibers within the TSB and ISB below the inner hair cells. In general, insult was greatest to middle- and basal-turn efferents, and longer survival times did not produce greater damage to, or loss of, efferents. These data suggest that at low concentrations, AF64A produces a partial yet selective degeneration of cochlear efferents within both the medial and lateral tracts, and that at the lowest concentrations used in these studies, AF64A produces a preferential insult on lateral olivocochlear efferents.
The Use of Ammonium Formate as a Mobile-Phase Modifier for LC-MS/MS Analysis of Tryptic Digests
Johnson, Darryl; Boyes, Barry; Orlando, Ron
2013-01-01
A major challenge facing current mass spectrometry (MS)-based proteomics research is the large concentration range displayed in biological systems, which far exceeds the dynamic range of commonly available mass spectrometers. One approach to overcome this limitation is to improve online reversed-phase liquid chromatography (RP-LC) separation methodologies. LC mobile-phase modifiers are used to improve peak shape and increase sample load tolerance. Trifluoroacetic acid (TFA) is a commonly used mobile-phase modifier, as it produces peptide separations that are far superior to other additives. However, TFA leads to signal suppression when incorporated with electrospray ionization (ESI), and thus, other modifiers, such as formic acid (FA), are used for LC-MS applications. FA exhibits significantly less signal suppression, but is not as effective of a modifier as TFA. An alternative mobile-phase modifier is the combination of FA and ammonium formate (AF), which has been shown to improve peptide separations. The ESI-MS compatibility of this modifier has not been investigated, particularly for proteomic applications. This work compares the separation metrics of mobile phases modified with FA and FA/AF and explores the use of FA/AF for the LC-MS analysis of tryptic digests. Standard tryptic-digest peptides were used for comparative analysis of peak capacity and sample load tolerance. The compatibility of FA/AF in proteomic applications was examined with the analysis of soluble proteins from canine prostate carcinoma tissue. Overall, the use of FA/AF improved online RP-LC separations and led to significant increases in peptide identifications with improved protein sequence coverage. PMID:24294112
The use of ammonium formate as a mobile-phase modifier for LC-MS/MS analysis of tryptic digests.
Johnson, Darryl; Boyes, Barry; Orlando, Ron
2013-12-01
A major challenge facing current mass spectrometry (MS)-based proteomics research is the large concentration range displayed in biological systems, which far exceeds the dynamic range of commonly available mass spectrometers. One approach to overcome this limitation is to improve online reversed-phase liquid chromatography (RP-LC) separation methodologies. LC mobile-phase modifiers are used to improve peak shape and increase sample load tolerance. Trifluoroacetic acid (TFA) is a commonly used mobile-phase modifier, as it produces peptide separations that are far superior to other additives. However, TFA leads to signal suppression when incorporated with electrospray ionization (ESI), and thus, other modifiers, such as formic acid (FA), are used for LC-MS applications. FA exhibits significantly less signal suppression, but is not as effective of a modifier as TFA. An alternative mobile-phase modifier is the combination of FA and ammonium formate (AF), which has been shown to improve peptide separations. The ESI-MS compatibility of this modifier has not been investigated, particularly for proteomic applications. This work compares the separation metrics of mobile phases modified with FA and FA/AF and explores the use of FA/AF for the LC-MS analysis of tryptic digests. Standard tryptic-digest peptides were used for comparative analysis of peak capacity and sample load tolerance. The compatibility of FA/AF in proteomic applications was examined with the analysis of soluble proteins from canine prostate carcinoma tissue. Overall, the use of FA/AF improved online RP-LC separations and led to significant increases in peptide identifications with improved protein sequence coverage.
Dissipative preparation of antiferromagnetic order in the Fermi-Hubbard model
NASA Astrophysics Data System (ADS)
Kaczmarczyk, J.; Weimer, H.; Lemeshko, M.
2016-09-01
The Fermi-Hubbard model is one of the key models of condensed matter physics, which holds a potential for explaining the mystery of high-temperature superconductivity. Recent progress in ultracold atoms in optical lattices has paved the way to studying the model’s phase diagram using the tools of quantum simulation, which emerged as a promising alternative to the numerical calculations plagued by the infamous sign problem. However, the temperatures achieved using elaborate laser cooling protocols so far have been too high to show the appearance of antiferromagnetic (AF) and superconducting quantum phases directly. In this work, we demonstrate that using the machinery of dissipative quantum state engineering, one can observe the emergence of the AF order in the Fermi-Hubbard model with fermions in optical lattices. The core of the approach is to add incoherent laser scattering in such a way that the AF state emerges as the dark state of the driven-dissipative dynamics. The proposed controlled dissipation channels described in this work are straightforward to add to already existing experimental setups.
Natural occurrence of aflatoxins and ochratoxin A in processed spices marketed in Malaysia.
Ali, Norhayati; Hashim, Noor Hasani; Shuib, Nor Shifa
2015-01-01
The analysis of aflatoxins (B1, B2, G1 and G2) and ochratoxin A (OTA) was performed in processed spices marketed in Penang, Malaysia, using immunoaffinity columns and HPLC equipped with fluorescence detector (HPLC-FD). The processed powdered spices analysed include dried chilli, fennel, cumin, turmeric, black and white pepper, poppy seed, coriander, 'garam masala', and mixed spices for fish, meat and chicken curry. Two different studies were carried out. The limit of detection (LOD) was 0.01 ng g(-1) for each aflatoxin (AF) and 0.10 ng g(-1) for OTA (signal-to-noise ratio = 3:1). In the first study, 34 commercial processed spices analysed with a mean level, range and incidence of positive samples for total AF were 1.61 ng g(-1), 0.01-9.34 ng g(-1) and 85%, respectively, and for AFB1 were 1.38 ng g(-1), 0.01-7.68 ng g(-1) and 85%, respectively. The mean level, range and incidence of positive samples for OTA were 2.21 ng g(-1), 0.14-20.40 ng g(-1) and 79%, respectively. Natural co-occurrence of AF and OTA was found in 25 (74%) samples. In the second study of 24 commercial processed spices, the mean level, range and incidence of positive samples for total AF were 8.38 ng g(-1), 0.32-31.17 ng g(-1) and 88%, respectively, and for AFB1 were 7.31 ng g(-1), 0.32-28.43 ng g(-1) and 83%, respectively. Fifteen positive samples for total AF and two positive samples for OTA exceeded the permissible Malaysian limit of 5 ng g(-1). Contamination of both mycotoxins in spices may represent another route of exposure to consumers due to their frequent and prolonged consumption, as spices are common ingredients in popular dishes among Asian countries.
Zuo, Hui; Svingen, Gard F T; Tell, Grethe S; Ueland, Per M; Vollset, Stein E; Pedersen, Eva R; Ulvik, Arve; Meyer, Klaus; Nordrehaug, Jan E; Nilsen, Dennis W T; Bønaa, Kaare H; Nygård, Ottar
2018-04-12
Although choline metabolism has been associated with atherosclerotic heart disease, less research attention has been paid to the associations of choline and its oxidative metabolite betaine with cardiac arrhythmias. We evaluated associations of plasma concentrations and dietary intakes of choline and betaine with long-term atrial fibrillation (AF) risk in a community-based cohort, HUSK ([the Hordaland Health Study] n=6949), and validated the findings in 2 patient cohorts: the Western Norway Coronary Angiography Cohort (n=4164) and the NORVIT (Norwegian B-Vitamin) Trial (n=3733). Information on AF was obtained from the CVDNOR (Cardiovascular Disease in Norway) project. In HUSK, WECAC (Western Norway Coronary Angiography Cohort), and NORVIT, 552, 411, and 663 AF cases were identified during a median follow-up time of 10.9, 7.3, and, 8.7 years, respectively. Plasma concentrations of choline and betaine were significantly positively associated with later AF risk after multivariable adjustments in HUSK. Such associations were independently replicated in the 2 external prospective patient cohorts. The pooled hazard ratio was 1.13 (95% confidence interval 1.08-1.19, P <0.001) and 1.16 (95% confidence interval 1.10-1.22, P <0.001) per SD increment for log-transformed choline and betaine, respectively. Moreover, dietary intake of choline was marginally associated with AF risk (pooled hazard ratio 1.29, 95% confidence interval 1.01-1.66, fifth versus first quintile), whereas no significant association was observed between dietary betaine and AF risk. Our findings indicate that plasma concentrations as well as dietary intake of choline, but not betaine, are associated with subsequent risk of AF, suggesting a potential role of choline metabolism in the pathogenesis of AF. URL: https://www.clinicaltrials.gov.Unique identifier: NCT00671346. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Mossahebi, Sina; Kovács, Sándor J
2014-01-01
Although the electrophysiologic derangement responsible for atrial fibrillation (AF) has been elucidated, how AF remodels the ventricular chamber and affects diastolic function (DF) has not been fully characterized. The previously validated Parametrized Diastolic Filling (PDF) formalism models suction-initiated filling kinematically and generates error-minimized fits to E-wave contours using unique load (x o ), relaxation (c), and stiffness (k) parameters. It predicts that E-wave deceleration time (DT) is a function of both stiffness and relaxation. Ascribing DT s to stiffness and DTr to relaxation such that DT=DT s +DT r is legitimate because of causality and their predicted and observed high correlation (r=0.82 and r=0.94) with simultaneous (diastatic) chamber stiffness (dP/dV) and isovolumic relaxation (tau), respectively. We analyzed simultaneous echocardiography-cardiac catheterization data and compared 16 age matched, chronic AF subjects to 16, normal sinus rhythm (NSR) subjects (650 beats). All subjects had diastatic intervals. Conventional DF parameters (DT, AT, E peak , E dur , E-VTI, E/E') and E-wave derived PDF parameters (c, k, DT s , DT r ) were compared. Total DT and DT s , DT r in AF were shorter than in NSR (p<0.005), chamber stiffness, (k) in AF was higher than in NSR (p<0.001). For NSR, 75% of DT was due to stiffness and 25% was due to relaxation whereas for AF 81% of DT was due to stiffness and 19% was due to relaxation (p<0.005). We conclude that compared to NSR, increased chamber stiffness is one measurable consequence of chamber remodeling in chronic, rate controlled AF. A larger fraction of E-wave DT in AF is due to stiffness compared to NSR. By trending individual subjects, this method can elucidate and characterize the beneficial or adverse long-term effects on chamber remodeling due to alternative therapies in terms of chamber stiffness and relaxation.
Microencapsulation of Biocides for Reduced Copper, Long-life Antifouling Coatings
2007-02-01
together with Microtek produce microencapsulated DCOIT. Laboratory facilities equipped to produce from 100g – 500kg batches of microcapsules . These...FINAL REPORT Microencapsulation of Biocides for Reduced Copper, Long-life Antifouling Coatings ESTCP Project WP-0306 FEBRUARY 2007...octyl-4-isothi azolin-3-one (DCOIT) hns been microencapsulated nnd incorporated into collUllercially relevanl AF coatings. Re•ulls demon•ll’ntt long
Resonance energy transfer between the active sites of creatine kinase from rabbit brain.
Grossman, S H
1990-09-03
Resonance energy transfer was measured between the active site domains of the brain isozyme of creatine kinase (CK-BB). The reactive thiol near the active sites, one on each subunit of the dimeric protein, was derivatized using 5-[2-[iodoacetyl)amino)ethyl]aminonaphthalene-1-sulfonic acid (AED), 2-[4'-iodoacetamidoanilino]naphthalene-6-sulfonic acid (AANS) and 5-iodoacetamidofluorescein (AF). Suitable donor/acceptor protein conjugated hybrids were prepared by controlled kinetics producing CK-BB-AED/AF and CK-BB-AANS/AF. Transfer efficiencies, measured from the quenching of the donor lifetime and steady-state sensitized acceptor emission, ranged from 0.10 to 0.17. From determination of the donor/acceptor overlap integrals, donor quantum yields and attempts to delimit the orientation factor using steady-state and phase-resolved anisotropy measurements, it was found that a suitable estimate of the range between the active sites was between 45 and 57 A. This range is similar to that reported previously for the muscle isozyme of creatine kinase (Grossman, S.H. (1989) Biochemistry 28, 4894-4902) but is a significantly greater distance than detected for the hybrid, myocardial specific isozyme (Grossman, S.H. (1983) Biochemistry 22, 5369-5375).
Engineered disc-like angle-ply structures for intervertebral disc replacement.
Nerurkar, Nandan L; Sen, Sounok; Huang, Alice H; Elliott, Dawn M; Mauck, Robert L
2010-04-15
To develop a construction algorithm in which electrospun nanofibrous scaffolds are coupled with a biocompatible hydrogel to engineer a mesenchymal stem cell (MSC)-based disc replacement. To engineer a disc-like angle-ply structure (DAPS) that replicates the multiscale architecture of the intervertebral disc. Successful engineering of a replacement for the intervertebral disc requires replication of its mechanical function and anatomic form. Despite many attempts to engineer a replacement for ailing and degenerated discs, no prior study has replicated the multiscale hierarchical architecture of the native disc, and very few have assessed the mechanical function of formed neo-tissues. A new algorithm for the construction of a disc analogue was developed, using agarose to form a central nucleus pulposus (NP) and oriented electrospun nanofibrous scaffolds to form the anulus fibrosus region (AF). Bovine MSCs were seeded into both regions and biochemical, histologic, and mechanical maturation were evaluated with in vitro culture. We show that mechanical testing in compression and torsion, loading methods commonly used to assess disc mechanics, reveal equilibrium and time-dependent behaviors that are qualitatively similar to native tissue, although lesser in magnitude. Further, we demonstrate that cells seeded into both AF and NP regions adopt distinct morphologies that mirror those seen in native tissue, and that, in the AF region, this ordered community of cells deposit matrix that is organized in an angle-ply configuration. Finally, constructs demonstrate functional development with long-term in vitro culture. These findings provide a new approach for disc tissue engineering that replicates multi-scale form and function of the intervertebral disc, providing a foundation from which to build a multi-scale, biologic, anatomically and hierarchically relevant composite disc analogue for eventual disc replacement.
Black-Maier, Eric; Kim, Sunghee; Steinberg, Benjamin A; Fonarow, Gregg C; Freeman, James V; Kowey, Peter R; Ansell, Jack; Gersh, Bernard J; Mahaffey, Kenneth W; Naccarelli, Gerald; Hylek, Elaine M; Go, Alan S; Peterson, Eric D; Piccini, Jonathan P
2017-09-01
Oral anticoagulation (OAC) therapy is associated with increased periprocedural risks after cardiac implantable electronic device (CIED) implantation. Patterns of anticoagulation management involving non-vitamin K antagonist oral anticoagulants (NOACs) have not been characterized. Anticoagulation strategies and outcomes differ by anticoagulant type in patients undergoing CIED implantation. Using the nationwide Outcomes Registry for Better Informed Treatment of Atrial Fibrillation, we assessed how atrial fibrillation (AF) patients undergoing CIED implantation were cared for and their subsequent outcomes. Outcomes were compared by oral anticoagulant therapy (none, warfarin, or NOAC) as well as by anticoagulation interruption status. Among 9129 AF patients, 416 (5%) underwent CIED implantation during a median follow-up of 30 months (interquartile range, 24-36). Of these, 60 (14%) had implantation on a NOAC. Relative to warfarin therapy, those on a NOAC were younger (70.5 years [range, 65-77.5 years] vs 77 years [range, 70-82 years]), had less valvular heart disease (15.0% vs 31.3%), higher creatinine clearance (67.3 [range, 59.7-99.0] vs 65.8 [range, 50.0-91.6]), were more likely to have persistent AF (26.7% vs 22.9%), and use concomitant aspirin (51.7% vs 35.2%). OAC therapy was commonly interrupted for CIED in 64% (n = 183 of 284) of warfarin patients and 65% (n = 39 of 60) of NOAC patients. Many interrupted patients received intravenous bridging anticoagulation: 33/183 (18%) interrupted warfarin and 4/39 (10%) interrupted NOAC patients. Thirty-day periprocedure bleeding and stroke adverse events were infrequent. Management of anticoagulation among AF patients undergoing CIED implantation is highly variable, with OAC being interrupted in more than half of both warfarin- and NOAC-treated patients. Bleeding and stroke events were infrequent in both warfarin and NOAC-treated patients. © 2017 The Authors. Clinical Cardiology published by Wiley Periodicals, Inc.
Bernardi, Aline Vianna; de Gouvêa, Paula Fagundes; Gerolamo, Luis Eduardo; Yonamine, Deborah Kimie; de Lourdes de Lima Balico, Laís; Uyemura, Sergio Akira; Dinamarco, Taisa Magnani
2018-04-30
A gene encoding an endo-1,4-β-glucanase (Afu6g01800) from A. fumigatus was cloned into the vector pET-28a(+) and expressed in the E. coli strain RosettaTM (DE3) pLysS. Sequence analysis indicated that the enzyme Af-EGL7 belonged to the GH7 family. The gene Af-egl7 encoded a protein comprising 460 amino acids, with a CBM1 domain at residues 424-460 and molecular mass of 52 kDa, as estimated by SDS-PAGE. This enzyme was optimally active at pH and temperatures ranging from 4.5 to 5.5 and from 40 to 60 °C, respectively. Mn 2+ addition significantly enhanced the Af-EGL7 cellulase activity by 233%, whereas SDS addition fully inhibited this activity. Higher activity was observed toward β-glucan than toward xyloglucan and CM-Cellulose, suggesting that the enzyme corresponds to a β-1,3-1,4-glucanase. qRT-PCR in different culture media helped to establish the time-course expression profile. Different polysaccharides induced the gene Af-egl7 in a time-dependent manner; in the particular case of the substrate sugarcane exploded bagasse (SEB), Af-egl7 was induced 2500-fold. Upon addition to a commercial cellulase cocktail, Af-EGL7 significantly improved SEB saccharification, which suggested that the enzyme Af-EGL7 had great potential to hydrolyze complex biomass. From a biotechnological point of view, A. fumigatus Af-EGL7 is a promising candidate to enhance enzyme cocktails used in biorefineries such as consolidated bioprocessing. Copyright © 2018 Elsevier Inc. All rights reserved.
Frankel, David S; Parker, Sarah E; Rosenfeld, Lynda E; Gorelick, Philip B
2015-08-01
The prevalence of atrial fibrillation (AF) is substantial and increasing. Stroke is common in AF and can have devastating consequences. Oral anticoagulants are effective in reducing stroke risk, but are underutilized. We sought to characterize the impact of stroke on AF patients and their caregivers, gaps in knowledge and perspective between physicians and patients, and barriers to effective communication and optimal anticoagulation use. A survey was administered to AF patients with and without history of stroke, caregivers of stroke survivors, and physicians across the range of specialties caring for AF and stroke patients. While AF patients (n = 499) had limited knowledge about stroke, they expressed great desire to learn more and take action to reduce their risk. They were often dissatisfied with the education they had received and desired high-quality written materials. Stroke survivors (n = 251) had poor functional outcomes and often underestimated the burden of caring for them. Caregivers (n = 203) also wished they had received more information about reducing stroke risk before their survivor's event. They commonly felt overwhelmed and socially isolated. Physicians (n = 504) did not prescribe anticoagulants as frequently as recommended by guidelines. Concerns about monitoring anticoagulation and patient compliance were commonly reported barriers. Physicians may underestimate patient willingness to take anticoagulants. We identified significant knowledge gaps among patients, caregivers, and physicians in relation to AF and stroke. Furthermore, gaps in perspective often lead to suboptimal communication and decision making. Increased education and better communication between all stakeholders are needed to reduce the impact of stroke in AF. Copyright © 2015 Heart Rhythm Society and National Stroke Association. Published by Elsevier Inc. All rights reserved.
Frankel, David S; Parker, Sarah E; Rosenfeld, Lynda E; Gorelick, Philip B
2015-08-01
The prevalence of atrial fibrillation (AF) is substantial and increasing. Stroke is common in AF and can have devastating consequences. Oral anticoagulants are effective in reducing stroke risk, but are underutilized. We sought to characterize the impact of stroke on AF patients and their caregivers, gaps in knowledge and perspective between physicians and patients, and barriers to effective communication and optimal anticoagulation use. A survey was administered to AF patients with and without history of stroke, caregivers of stroke survivors, and physicians across the range of specialties caring for AF and stroke patients. While AF patients (n = 499) had limited knowledge about stroke, they expressed great desire to learn more and take action to reduce their risk. They were often dissatisfied with the education they had received and desired high-quality written materials. Stroke survivors (n = 251) had poor functional outcomes and often underestimated the burden of caring for them. Caregivers (n = 203) also wished they had received more information about reducing stroke risk before their survivor's event. They commonly felt overwhelmed and socially isolated. Physicians (n = 504) did not prescribe anticoagulants as frequently as recommended by guidelines. Concerns about monitoring anticoagulation and patient compliance were commonly reported barriers. Physicians may underestimate patient willingness to take anticoagulants. We identified significant knowledge gaps among patients, caregivers, and physicians in relation to AF and stroke. Furthermore, gaps in perspective often lead to suboptimal communication and decision making. Increased education and better communication between all stakeholders are needed to reduce the impact of stroke in AF. Copyright © 2015 Heart Rhythm Society and National Stroke Association. Published by Elsevier Inc. All rights reserved.
EARLY: a pilot study on early diagnosis of atrial fibrillation in a primary healthcare centre.
Benito, Luisa; Coll-Vinent, Blanca; Gómez, Eva; Martí, David; Mitjavila, Joan; Torres, Ferran; Miró, Òscar; Sisó, Antoni; Mont, Lluís
2015-11-01
Atrial fibrillation (AF) is associated with high morbidity and mortality. Early diagnosis is likely to improve therapy and prognosis. The study objective was to evaluate the usefulness of a programme for early diagnosis of AF in patients from an urban primary care centre. Participants were recruited from a randomized sample of patients not diagnosed with AF but having relevant risk factors: age ≥ 65 years, ischaemic and/or valvular heart disease, congestive heart failure, hypertension, and/or diabetes. Patients were randomly assigned to the intervention group (IG) or control group (CG). The intervention included (i) initial visit with clinical history, electrocardiogram, and instruction about pulse palpation and warning signs and (ii) electrocardiogram every 6 months during a 2-year follow-up. The main endpoint of the study was the proportion of new cases diagnosed at 6 months. Secondary endpoints were number of new AF diagnoses and complications associated with the arrhythmia in both groups. A total of 928 patients were included (463 IG and 465 CG). At 6 months, AF was diagnosed in 8 IG patients and 1 CG patient (1.7 vs. 0.2%, respectively, P = 0.018). After 2 years of follow-up, 11 IG patients and 6 CG patients had newly diagnosed AF (2.5 vs. 1.3%, respectively, P = 0.132). Time to first diagnosis of AF was shorter in IG patients [median (inter-quartile range): 7 (192) days vs. 227 (188.5) days in CG, P = 0.029]. The simple screening proposed could be useful for the early detection of AF in primary care. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
2014-01-01
Background Throughout Asia, including Japan, rice plants are cultivated in a wide range of areas from lowlands to highlands and are frequently exposed to fog, including acid fog. Some physiological studies have shown that acid fog can be a stress factor for plants. We analyzed the gene expression profiles of rice plants treated with artificially prepared simulated acid fog (SiAF) or simulated neutral fog (SiNF) for 1 or 7 days. Results Microarray analysis results suggested that both the SiAF and the SiNF treatments induced the expression of genes involved in the defense and stress responses in rice plants. Induction of such genes was detected in plants treated with SiAF for 1 day, and the number of induced genes increased in plants treated with SiAF for 7 days. The genes for defense and stress responses were also induced by SiNF for 7 days, although they were not induced by SiNF for 1 day. The gene expression profiles of the SiAF-treated and the SiNF-treated plants were compared to those of plants treated with other stress factors. The comparison revealed that both SiAF and SiNF treatments have similar effects to biotic stresses and ozone stress. The genes encoding NADPH oxidase and germin, which function in apoplasts, were also induced by SiAF, SiNF and biotic stresses. Conclusions These findings suggest that both the SiAF and the SiNF treatments may result in oxidative stress through the apoplastic production of reactive oxygen species. PMID:24987489
Randolph, Tiffany C.; Simon, DaJuanicia N.; Thomas, Laine; Allen, Larry A.; Fonarow, Gregg C.; Gersh, Bernard J.; Kowey, Peter R.; Reiffel, James A.; Naccarelli, Gerald V.; Chan, Paul S.; Spertus, John A.; Peterson, Eric D.; Piccini, Jonathan P.
2016-01-01
Background As treatment options for atrial fibrillation (AF) increase, more attention is focused on patients’ experiences and quality of life (QoL). However, little is known about the factors associated with these outcomes. Methods The Atrial Fibrillation Effect on QualiTy-of-life (AFEQT) is a disease-specific QoL tool for AF, with domain and summary scores ranging from 0 (the worst QoL) to 100. Using multivariable linear regression, we evaluated factors associated with baseline AFEQT Summary and Subscale Scores in ORBIT AF, a large, community-based AF registry. Independent associations were reported as coefficient estimates in scores and 95% confidence intervals (CI). Results Overall, AFEQT was assessed in 2,007 AF outpatients from 99 sites. Median age (IQR) was 76 years (67-82) and 43% were female. The median AFEQT summary score was 82 (67-94). Female sex, younger age, new onset AF, higher heart rate, obstructive sleep apnea, symptomatic heart failure (HF), chronic obstructive pulmonary disease and coronary artery disease were all independently associated with reduced QoL. Female sex [Estimate −7.03, 95% CI (−9.31, −4.75)] and new onset versus permanent AF [Estimate −7.44, 95% CI (−11.03, −3.84)] were independently associated with increased symptoms. NYHA Class III or IV HF [Estimate -14.44, 95% CI (−19.46, −8.76)] and female sex [Estimate −7.91, 95% CI (−9.95, −5.88)] were most independently associated with impaired daily activities. Conclusions QoL in patients with AF varies widely and is associated with several patient factors. Understanding patient factors independently associated with worse QoL can be a foundation for tailoring treatment. PMID:27914493
Adabag, A Selcuk; Mithani, Salima; Al Aloul, Basel; Collins, Dorothea; Bertog, Stefan; Bloomfield, Hanna E
2009-05-01
Peroxisome proliferator-activated receptor alpha (PPARalpha) activators reduce inflammation and oxidative stress. Inflammation plays an important role in the initiation and maintenance of atrial fibrillation (AF). It has been suggested that PPARalpha activators may have antiarrhythmic properties, but no clinical data exist. The objective of this study was to investigate whether the PPARalpha activator gemfibrozil prevents or delays the development of AF in patients with coronary heart disease. We retrospectively analyzed the electrocardiograms (ECGs) performed in the Veterans Affairs High-Density Lipoprotein Cholesterol Intervention Trial, a multicenter, randomized, double-blinded, secondary prevention trial of gemfibrozil and matching placebo. The ECGs were performed annually or biannually and when clinically indicated. Participants who were in AF on baseline ECG were excluded from the present analysis. Relative risk for AF was calculated from Cox regression with death as a competing risk factor. A total of 12,605 ECGs from 2,130 participants were interpreted (5.9 +/- 2.1 ECGs per participant, range 2-20). At baseline, the gemfibrozil (n = 1,070) and placebo (n = 1,060) groups were well matched. Mean age was 64.1 +/- 7.1 years. Over 4.4 +/- 1.5 years of follow-up, 123 (5.8%) participants developed new AF. There was no difference in AF incidence between the gemfibrozil and placebo groups (64/1,070 vs 59/1,060, respectively; P = .33). In Cox regression, the risk of AF was similar between the 2 study groups (hazard ratio 1.04, 95% CI 0.73-1.49, P = .82). In this post hoc analysis of a multicenter, double-blinded, randomized controlled trial, the PPARalpha activator gemfibrozil did not reduce the 4-year incidence of AF among men with coronary heart disease.
Shepherd, J; Jones, J; Frampton, G K; Tanajewski, L; Turner, D; Price, A
2008-06-01
To assess the clinical and cost-effectiveness of magnesium sulphate compared with sotalol, and to assess the clinical effectiveness of magnesium sulphate compared with placebo in the prevention of atrial fibrillation (AF) in patients who have had a coronary artery bypass graft (CABG). Major electronic databases were searched from December 2003 to May 2007. Selected studies were assessed, subjected to data extraction using a standard template and quality assessment using published criteria. A simple short-term economic model was developed, informed by a systematic review of economic evaluations and populated with data from a review of costing/resource-use studies and other published studies. The cost-effectiveness of magnesium sulphate as prophylaxis was estimated for a set of base-case assumptions and the robustness of these results was assessed using deterministic and probabilistic sensitivity analysis. Twenty-two papers met the inclusion criteria reporting 15 trials which all compared magnesium sulphate with placebo or control. They ranged in size from 15 to 176 patients randomised, and were conducted in Europe, the USA and Canada. The standard of reporting was generally poor, with details of key methodological attributes difficult to elucidate. No trials were identified that specifically aimed to compare magnesium sulphate with sotalol. Of 1070 patients in the pooled magnesium group, 230 (21%) developed postoperative AF, compared with 307 of 1031 (30%) patients in the placebo or (control) group. Meta-analysis using a fixed-effects model generated a pooled odds ratio (OR) that was significantly less than 1.0 [OR=0.65, 95% confidence interval (CI) 0.53 to 0.79, test for overall effect p<0.0001], but with statistically significant heterogeneity (I2=63.4%, p=0.0005). Two randomised controlled trials (RCTs) were notable as they had relatively lower ORs in favour of magnesium sulphate. When these were removed from the analyses the pooled OR remained statistically significant, but heterogeneity no longer remained significant. These two studies tended to impart a highly significant reduction in the odds of AF to whichever subgroup they were analysed in. When studies were ordered by total duration of prophylaxis, an apparent relationship between duration and odds of AF was evident, with decreasing odds of AF as duration of prophylaxis increased. This was confirmed by linear regression analysis (R2=0.743, p<0.001). When the data were grouped into three classes according to duration, a statistically significant intervention effect was only present for the longest duration (OR=0.12, 95% CI 0.06 to 0.23, p=0.00001). Statistically significant intervention effects were associated with the initiation of prophylaxis 12 hours or more before surgery (OR 0.26; 95% CI 0.16 to 0.44, test for overall effect p=0.00001, fixed-effects model) and less than 12 hours before surgery or during the surgery itself (OR=0.73, 95% CI 0.56 to 0.97, test for overall effect p = 0.03, fixed-effects model), but not when prophylaxis was initiated at the end of surgery or postsurgery (OR=0.85, 95% CI 0.59 to 1.22, p=0.37, fixed-effects model). When studies were ordered by total dose of intravenous magnesium sulphate (<25 g), the odds of AF were independent of the dose. A notable exception was that for a total dose of 9 g magnesium sulphate; here the odds of AF were significantly reduced relative to the control group, although this may be explained by the fact that these studies had excluded patients who were on antiarrhythmic drugs and so may have been at higher risk of AF. Sixty-three potentially relevant references about cost-effectiveness were identified, but no economic evaluations of intravenous magnesium alone as prophylaxis against AF following CABG, compared with sotalol as prophylaxis or no prophylaxis, were identified. Studies reporting resource use by patients with AF following CABG suggest that while AF significantly increased inpatient stays, by up to 2.3 days in the intensive care unit (ICU) and 3.4 days on the ward, differences in length of stay and costs between patients receiving prophylaxis and those not receiving prophylaxis were not statistically significant. In the base-case analysis, magnesium sulphate prophylaxis resulted in 0.081 fewer cases of AF at an incremental cost of 2.55 pounds sterling. The incremental cost-effectiveness ratio (ICER) was 32 pounds sterling per AF case avoided. The estimated difference in average length of stay between the prophylaxis and no-prophylaxis strategies was only 0.24 days, despite a large assumed difference of 3 days for patients experiencing AF in each group (1 extra day in the ICU and 2 extra days on the ward). In a deterministic sensitivity analysis the greatest variation in ICERs was observed for input parameters relating to the baseline risk of AF following CABG and the effectiveness of prophylaxis, cost of prophylaxis and the resource consequences of postoperative AF. The largest ICER (2092 pounds sterling) in the sensitivity analysis was associated with increasing the length of patients' preoperative stay. In the base case it was assumed that admission routines would be identical under both strategies. However, patients receiving prophylaxis by intravenous infusion may have longer preoperative stays. In a probabilistic analysis the majority of the simulations were associated with improved outcomes (in this case fewer cases of AF), but also higher costs. Prophylaxis was the dominant strategy (better outcome at lower cost) in about 41% of the simulations using the base-case assumptions. Under an alternative scenario where patients receiving prophylaxis are admitted for longer before their operation, to receive their initial infusion, the proportion of simulations where prophylaxis dominates fell to around 5%. The probability of being cost-effective was 99% at a willingness to pay (WTP) threshold of 2000 pounds sterling per AF case avoided and 100% at a WTP threshold of 5000 pounds sterling per AF case avoided under the base-case assumptions. Under the alternative scenario of longer preoperative stays the probability of being cost-effective at these two threshold values fell to 48% and 93%, respectively. It is unclear what the appropriate decision threshold should be, given that this model used intermediate rather than final outcomes. No RCTs were identified that specifically aimed to compare intravenous magnesium with sotalol as prophylaxis for AF in patients undergoing CABG. Intravenous magnesium, compared with placebo or control, is effective in preventing postoperative AF, as confirmed by a statistically significant intervention effect based on pooled analysis of 15 RCTs. It was also found that AF was less likely to occur when a longer duration of prophylaxis was used, and the earlier that prophylaxis is started; however, this finding was associated with two RCTs that had more favourable results than the other trials. No clear relationship between dose and AF was observed, although a lower constant dose rate was associated with the lowest odds of AF. Further research should investigate the relationship between dose, dose rate, duration of prophylaxis, timing of initiation of therapy and patient characteristics, such as degree of risk for AF. This will provide stronger evidence for the optimum delivery of intravenous magnesium in patients undergoing CABG. In the base-case analysis in the economic model, magnesium sulphate prophylaxis reduced the number of postoperative AF cases at a modest increase in cost. The results of the economic analysis are highly sensitive to variation in certain key parameters. Prophylaxis is less likely to be a cost-effective option if it requires changes in admission routines that result in longer preoperative stays than would be the case without prophylaxis.
NASA Astrophysics Data System (ADS)
Tomioka, Y.; Ito, T.; Sawa, A.
2018-01-01
For half-doped manganese oxides that have a perovskite structure, R E1 -xA ExMn O3 (x =0.5 ) (RE and AE are rare-earth and alkaline-earth elements, respectively), the phase competition (stability) between the antiferromagnetic charge- or orbital-ordered insulator (CO/OO AFI), ferromagnetic metal (FM), layered (A-type) antiferromagnetic phase [AF(A)], and spin-glass-like insulator (SGI), have been studied using single crystals prepared by the floating zone method. The CO/OO AFI, FM, AF(A), and SGI are displayed on the plane of the disorder (the variance of the RE and AE cations) versus the effective one-electron bandwidth (the averaged ionic radius of the RE and AE). In the plane of the disorder versus the effective one-electron bandwidth, similar to the phase diagram of R E1 -xA ExMn O3 (x =0.45 ), the CO/OO AFI, FM, and SGI dominate at the lower-left, right, and upper regions, respectively. However, the CO/OO AFI for x =0.5 is more stable than that for x =0.45 , and it expands to the plane points that correspond to the R E0.5S r0.5Mn O3 (R E =Nd and Sm) specimens as the hole concentration is commensurate with the ordering of M n3 + /M n4 + with a ratio of 1/1. The y -dependent electronic phases for R E0.5(Sr1-yB ay ) 0.5Mn O3 (0 ≤y ≤0.5 ) (R E =Sm , N d0.5S m0.5 , Nd, and Pr) show that the AF(A) intervenes between the CO/OO AFI and FM. Besides the region around (La1-yP ry ) 0.5S r0.5Mn O3 (0 ≤y ≤1 ) that has a smaller disorder, the AF(A) also exists at the regions around R E0.5(Sr1-yB ay ) 0.5Mn O3 (0
Marazzi, Giuseppe; Iellamo, Ferdinando; Volterrani, Maurizio; Lombardo, Mauro; Pelliccia, Francesco; Righi, Daniela; Grieco, Fabrizia; Cacciotti, Luca; Iaia, Luigi; Caminiti, Giuseppe; Rosano, Giuseppe
2012-01-01
Self-monitoring home blood pressure (BP) devices are currently recommended for long-term follow-up of hypertension and its management. Some of these devices are integrated with algorithms aimed at detecting atrial fibrillation (AF), which is common essential hypertension. This study was designed to compare the diagnostic accuracy of two widely diffused home BP monitoring devices in detecting AF in an unselected population of outpatients referred to a hypertension clinic because of high BP. In 503 consecutive patients the authors simultaneously compared the accuracy of the Microlife(®) BP A200 Plus (Microlife) and the OMRON(®) M6 (OMRON) home BP devices, in detecting AF. Systolic and diastolic BP as well as heart rate (HR) values detected by the two devices were not significantly different. Pulse irregularity was detected in 124 and 112 patients with the OMRON M6 and Microlife BP A200 Plus devices, respectively. Simultaneous electrocardiogram (ECG) recording revealed that pulse irregularity was due to AF in 101 patients. Pulse irregularity detected by the OMRON M6 device corresponded to AF in 101, to supraventricular premature beats in 18, and to frequent premature ventricular beat in five patients, respectively. Pulse irregularity detected by the Microlife BP A200 Plus device corresponded to AF in 93, to supraventricular premature beats in 14, and to ventricular premature beats in five patients. The sensitivity for detecting AF was 100%, the specificity was 92%, and diagnostic accuracy 95% for the OMRON M6 and 100%, 92%, and 95 for the Microlife BP A200 Plus, respectively. AF was newly diagnosed by ECG recordings in 47 patients, and was detected in all patients by the OMRON device, and in 42 patients by the Microlife device. These results indicate that OMRON M6 is more accurate than Microlife BP A200 Plus in detecting AF in patients with essential hypertension. Widespread use of these devices in hypertensive patients could be of clinical benefit for the early diagnosis and treatment of this arrhythmia and related consequences.
Maintaining a Distributed File System by Collection and Analysis of Metrics
NASA Technical Reports Server (NTRS)
Bromberg, Daniel
1997-01-01
AFS(originally, Andrew File System) is a widely-deployed distributed file system product used by companies, universities, and laboratories world-wide. However, it is not trivial to operate: runing an AFS cell is a formidable task. It requires a team of dedicated and experienced system administratores who must manage a user base numbring in the thousands, rather than the smaller range of 10 to 500 faced by the typical system administrator.
Feng, Dan Qing; He, Jian; Chen, Si Yu; Su, Pei; Ke, Cai Huan; Wang, Wei
2018-06-02
The extensive use of copper and booster biocides in antifouling (AF) paints has raised environmental concerns and the need to develop new AF agents. In the present study, 18 alkaloids derived from terrestrial plants were initially evaluated for AF activity using laboratory bioassays with the bryozoan Bugula neritina and the barnacle Balanus albicostatus. The results showed that 4 of the 18 alkaloids were effective in inhibiting larval settlement of B. neritina, with an EC 50 range of 6.18 to 43.11 μM, and 15 of the 18 alkaloids inhibited larval settlement of B. albicostatus, with EC 50 values ranging from 1.18 to 67.58 μM. Field trials that incorporated five alkaloids respectively into paints with 20% w/w indicated an in situ AF efficiency of evodiamine, strychnine, camptothecin (CPT), and cepharanthine, with the most potent compound being CPT, which also exhibited stronger AF efficiency than the commercial antifoulants cuprous oxide and zinc pyrithione in the field over a period of 12 months. Further field trials with different CPT concentrations (0.1 to 20% w/w) in the paints suggested a concentration-dependent AF performance in the natural environment, and the effective concentrations to significantly inhibit settlement of biofoulers in the field were ≥ 0.5% w/w (the efficiency of 0.5% w/w lasted for 2 months). Moreover, CPT toxicity against the crustacean Artemia salina, the planktonic microalgae Phaeodactylum tricornutum and Isochrysis galbana, was examined. The results showed that 24 h LC 50 of CPT against A. salina was 20.75 μM, and 96 h EC 50 (growth inhibition) values of CPT to P. tricornutum and I. galbana were 55.81 and 6.29 μM, respectively, indicating that CPT was comparatively less toxic than several commercial antifoulants previously reported. Our results suggest the novel potential application of CPT as an antifoulant.
Aflatoxin exposure in utero causes growth faltering in Gambian infants.
Turner, Paul C; Collinson, Andrew C; Cheung, Yin Bun; Gong, Yunyun; Hall, Andrew J; Prentice, Andrew M; Wild, Christopher P
2007-10-01
Growth faltering in West African children has previously been associated with dietary exposure to aflatoxins, particularly upon weaning. However, in animal studies in utero exposure to low levels of aflatoxin also results in growth faltering. This study investigated the effect of in utero aflatoxin exposure on infant growth in the first year of life in The Gambia. Height and weight were measured for 138 infants at birth and at regular monthly intervals for one year. Aflatoxin-albumin (AF-alb) adduct level was measured in maternal blood during pregnancy, in cord blood and in infants at age 16 weeks. The geometric mean AF-alb levels were 40.4 pg/mg (range 4.8-260.8 pg/mg), 10.1 pg/mg (range 5.0-189.6 pg/mg) and 8.7 pg/mg (range 5.0-30.2 pg/mg) in maternal, cord and infant blood, respectively. AF-alb in maternal blood was a strong predictor of both weight (P = 0.012) and height (P = 0.044) gain, with lower gain in those with higher exposure. A reduction of maternal AF-alb from 110 pg/mg to 10 pg/mg would lead to a 0.8 kg increase in weight and 2 cm increase in height within the first year of life. This study shows a strong effect of maternal aflatoxin exposure during pregnancy on growth in the first year of life and thus extends earlier observations of an association between aflatoxin exposure during infancy and growth faltering. The findings imply value in targeting intervention strategies at early life exposures.
Determination of hydrogen permeability in commercial and modified superalloys
NASA Technical Reports Server (NTRS)
Bhattacharyya, S.; Peterman, W.
1983-01-01
The results of hydrogen permeability measurements on several iron- and cobalt-base alloys as well as on two long-ranged ordered alloys over the range of 705 to 870 C (1300 to 1600 F) are summarized. The test alloys included wrought alloys N-155, IN 800, A-286, 19-9DL, and 19-9DL modifications with aluminum, niobium, and misch metal. In addition, XF-818, CRM-6D, SA-F11, and HS-31 were evaluated. Two wrought long-range ordered alloys, Ni3Al and (Fe,Ni)3(V,Al) were also evaluated. All tests were conducted at 20.7 MPa pressure in either pure and/or 1% CO2-doped H2 for test periods as long as 133 h. Detailed analyses were conducted to determine the relative permeability rankings of these alloys and the effect of doping, exit surface oxidation, specimen design variations, and test duration on permeability coefficient, and permeation activation energies were determined. The two long-range ordered alloys had the lowest permeability coefficients in pure H2 when compared with the eight commercial alloys and their modifications. With CO2 doping, significant decrease in permeability was observed in commercial alloys--no doped tests were conducted with the long-range ordered alloys.
NASA Astrophysics Data System (ADS)
Verret, S.; Simard, O.; Charlebois, M.; Sénéchal, D.; Tremblay, A.-M. S.
2017-09-01
Since its experimental discovery, many phenomenological theories successfully reproduced the rapid rise of the Hall number nH, going from p at low doping to 1 +p at the critical doping p* of the pseudogap in superconducting cuprates. Further comparison with experiments is now needed in order to narrow down candidates. In this paper, we consider three previously successful phenomenological theories in a unified formalism—an antiferromagnetic mean field (AF), a spiral incommensurate antiferromagnetic mean field (sAF), and the Yang-Rice-Zhang (YRZ) theory. We find a rapid rise in the specific heat and a rapid drop in the Seebeck coefficient for increasing doping across the transition in each of those models. The predicted rises and drops are locked, not to p*, but to the doping where antinodal electron pockets, characteristic of each model, appear at the Fermi surface shortly before p*. While such electron pockets are still to be found in experiments, we discuss how they could provide distinctive signatures for each model. We also show that the range of doping where those electron pockets would be found is strongly affected by the position of the van Hove singularity.
Boriani, Giuseppe; Manolis, Antonis S; Tukkie, Raymond; Mont, Lluis; Pürerfellner, Helmut; Santini, Massimo; Inama, Giuseppe; Serra, Paolo; Gulizia, Michele; Samoilenko, Igor Vasilyevich; Wolff, Claudia; Holbrook, Reece; Gavazza, Federica; Padeletti, Luigi
2015-06-01
Many patients who suffer from bradycardia and need cardiac pacing also have atrial fibrillation (AF). New pacemaker algorithms, such as atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), have been specifically designed to reduce AF occurrence and duration and to minimize the detrimental effects of right ventricular pacing. The randomized MINimizE Right Ventricular pacing to prevent Atrial fibrillation and heart failure trial established that DDDRP + MVP pacing modality reduced permanent AF in bradycardia patients as compared with standard dual-chamber pacing (DDDR). The aim of this study was to estimate the cost savings due to lower AF-related health care utilization events based on health care costs from the United States and the European Union. Dual-chamber pacemaker patients with a history of paroxysmal or persistent AF were randomly assigned to receive DDDR (n = 385) or the advanced features (DDDRP + MVP; n = 383). We used published health care costs from the United States and the European Union (Italy, Spain, and the United Kingdom) to estimate the costs associated with AF-related hospitalizations and emergency visits. The rate of AF-related hospitalizations was significantly lower in the DDDRP + MVP group than in the conventional pacemaker group (DDDR group; 42% reduction; incidence rate ratio 0.58). Similarly, a significant reduction of 68% was observed for AF-related emergency department visits (incidence rate ratio 0.32; P < .001). As a consequence, DDDRP + MVP could potentially reduce health care costs by 40%-44%. Over a ten-year period, the cost savings per 100 patients ranged from $35,702 in the United Kingdom to $121,831 in the United States. New pacing algorithms such as DDDRP + MVP used in the MINimizE Right Ventricular pacing to prevent Atrial fibrillation and heart failure trial successfully reduced AF-related health care utilization, resulting in significant cost savings to payers. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Hussein, Ayman A; Bartz, Traci M; Gottdiener, John S; Sotoodehnia, Nona; Heckbert, Susan R; Lloyd-Jones, Donald; Kizer, Jorge R; Christenson, Robert; Wazni, Oussama; deFilippi, Christopher
2015-05-01
Various mechanisms in cardiac remodeling related to atrial fibrillation (AF) lead to elevated circulating cardiac troponin levels, but little is known about such elevations upstream to AF onset. The purpose of this study was to study the association between circulating troponin levels as assessed by a highly sensitive cardiac troponin T (hs-cTnT) assay and incident atrial fibrillation (AF). In a large prospective cohort of ambulatory older adults [the Cardiovascular Health Study (CHS)], hs-cTnT levels were measured in sera that were collected at enrollment from 4262 participants without AF (2871 with follow-up measurements). Incident AF was identified by electrocardiograms during CHS visits, hospital discharge diagnoses, and Medicare files, including outpatient and physician claims diagnoses. Over median follow-up of 11.2 years (interquartile range 6.1-16.5), 1363 participants (32.0%) developed AF. Higher baseline levels of hs-cTnT were associated with incident AF in covariate-adjusted analyses accounting for demographics, traditional risk factors, and incident heart failure in time-dependent analyzes (hazard ratio for 3rd tertile vs undetectable 1.75, 95% confidence interval 1.48-2.08). This association was statistically significant in analyses that additionally adjusted for biomarkers of inflammation and hemodynamic strain (hazard ratio for 3rd tertile vs undetectable 1.38, 95% confidence interval 1.16-1.65). Significant associations were also found when hs-cTnT levels were treated as a continuous variable and when examining change from baseline of hs-cTnT levels and incident AF. The findings show a significant association of circulating troponin levels in ambulatory older adults with incident AF beyond that of traditional risk factors, incident heart failure, and biomarkers of inflammation and hemodynamic strain. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Trentin, Luca; Bresolin, Silvia; Giarin, Emanuela; Bardini, Michela; Serafin, Valentina; Accordi, Benedetta; Fais, Franco; Tenca, Claudya; De Lorenzo, Paola; Valsecchi, Maria Grazia; Cazzaniga, Giovanni; Kronnie, Geertruy Te; Basso, Giuseppe
2016-10-04
To induce and sustain the leukaemogenic process, MLL-AF4+ leukaemia seems to require very few genetic alterations in addition to the fusion gene itself. Studies of infant and paediatric patients with MLL-AF4+ B cell precursor acute lymphoblastic leukaemia (BCP-ALL) have reported mutations in KRAS and NRAS with incidences ranging from 25 to 50%. Whereas previous studies employed Sanger sequencing, here we used next generation amplicon deep sequencing for in depth evaluation of RAS mutations in 36 paediatric patients at diagnosis of MLL-AF4+ leukaemia. RAS mutations including those in small sub-clones were detected in 63.9% of patients. Furthermore, the mutational analysis of 17 paired samples at diagnosis and relapse revealed complex RAS clone dynamics and showed that the mutated clones present at relapse were almost all originated from clones that were already detectable at diagnosis and survived to the initial therapy. Finally, we showed that mutated patients were indeed characterized by a RAS related signature at both transcriptional and protein levels and that the targeting of the RAS pathway could be of beneficial for treatment of MLL-AF4+ BCP-ALL clones carrying somatic RAS mutations.
Heat Shock Response of Archaeoglobus fulgidus†
Rohlin, Lars; Trent, Jonathan D.; Salmon, Kirsty; Kim, Unmi; Gunsalus, Robert P.; Liao, James C.
2005-01-01
The heat shock response of the hyperthermophilic archaeon Archaeoglobus fulgidus strain VC-16 was studied using whole-genome microarrays. On the basis of the resulting expression profiles, approximately 350 of the 2,410 open reading frames (ORFs) (ca. 14%) exhibited increased or decreased transcript abundance. These span a range of cell functions, including energy production, amino acid metabolism, and signal transduction, where the majority are uncharacterized. One ORF called AF1298 was identified that contains a putative helix-turn-helix DNA binding motif. The gene product, HSR1, was expressed and purified from Escherichia coli and was used to characterize specific DNA recognition regions upstream of two A. fulgidus genes, AF1298 and AF1971. The results indicate that AF1298 is autoregulated and is part of an operon with two downstream genes that encode a small heat shock protein, Hsp20, and cdc48, an AAA+ ATPase. The DNase I footprints using HSR1 suggest the presence of a cis-binding motif upstream of AF1298 consisting of CTAAC-N5-GTTAG. Since AF1298 is negatively regulated in response to heat shock and encodes a protein only distantly related to the N-terminal DNA binding domain of Phr of Pyrococcus furiosus, these results suggest that HSR1 and Phr may belong to an evolutionarily diverse protein family involved in heat shock regulation in hyperthermophilic and mesophilic Archaea organisms. PMID:16109946
McCabe, James M.; Johnson, Colleen J; Marcus, Gregory M
2011-01-01
Atrial fibrillation (AF) is often managed by general internal medicine physicians. Available data suggest that guidelines regarding AF management are often not followed, but the reasons for this remain unknown. We sought to assess the knowledge and beliefs of internists regarding strategies to treat AF. We conducted a national electronic survey of internal medicine physicians regarding their perceptions of optimal AF management, with an emphasis on the rationale for choosing a rhythm or rate control strategy. One hundred and forty-eight physicians from 36 different states responded (representing at least 19% of unique e-mails opened). Half of the respondents reported managing their AF patients independently without referral to a cardiologist. Seventy-three percent of participants believe a rhythm control strategy conveys a decreased stroke risk, 64% believe there is a mortality benefit to rhythm control, and 55% think that it would help avoid long term anticoagulation. Comparing those who prefer a rhythm control strategy to everyone else, those who favor rhythm control statistically significantly more often believe that rhythm control reduces the risk for stroke (96% versus 67%, p=0.009) and that rhythm control allows for the discontinuation of anticoagulation therapy (76% versus 49%, p=0.045). In conclusion, contrary to available data in clinical trials and recent guidelines regarding the rationale for choosing a rhythm control strategy in treating AF, the majority of study participants believe that rhythm control decreases stroke risk, decreases mortality, and allows for discontinuation of anticoagulation therapy. These prevalent misconceptions may substantially contribute to guideline non-adherence. PMID:19195516
Medici, Emília Patrícia; Mangini, Paulo Rogerio; Fernandes-Santos, Renata Carolina
2014-10-01
Abstract The lowland tapir (Tapirus terrestris) is found in South America and is listed as Vulnerable to Extinction by the International Union for Conservation of Nature, Red List of Threatened Species. Health issues, particularly infectious diseases, are potential threats for the species. Health information from 65 wild tapirs from two Brazilian biomes, Atlantic Forest (AF) and Pantanal (PA), were collected during a long-term study (1996-2012). The study included physic, hematologic and biochemical evaluations, microbiologic cultures, urinalysis, and serologic analyses for antibodies against 13 infectious agents (viral and bacterial). The AF and PA tapirs were significantly different for several hematologic and biochemical parameters. Ten bacteria taxa were identified in the AF and 26 in the PA. Antibodies against five viruses were detected: Bluetongue virus, eastern equine encephalitis virus, western equine encephalitis virus, infectious bovine rhinotracheitis virus, and porcine parvovirus. A high prevalence of exposure to Leptospira interrogans (10 serovars: Autumnalis, Bratislava, Canicola, Copenhageni, Grippotyphosa, Hardjo, Hebdomadis, Icterohaemorrhagiae, Pomona, and Pyrogenes) was detected in both the AF and PA sites. A greater diversity of serovars and higher antibody titers were found in the PA. Statistically significant differences between sites were found for L. interrogans, equine encephalitis virus, and porcine parvovirus. Based on physical evaluations, both AF and PA populations were healthy. The differences in the overall health profile of the AF and PA tapir populations appear to be associated with environmental factors and infectious diseases ecology. The extensive datasets on hematology, biochemistry, urinalysis, and microbiology results from this paper can be used as reference values for wild tapirs.
Centurión Md PhD Facc, Osmar Antonio
2014-01-01
The necessity to add two antiplatelet agents to an oral anticoagulant (OAC) often arises in patients with atrial fibrillation (AF) in routine clinical practice. The majority of AF patients have an indication for continuous OAC, and coronary artery disease co-exists in 25% of these patients. The increasing use of drug-eluting stents to minimize intrastent restenosis necessitates long-term dual antiplatelet therapy with Aspirin plus Clopidogrel to reduce the risk of early and late stent thrombosis. Combined aspirin-clopidogrel therapy, however, is less effective in preventing stroke compared with OAC alone in AF patients, and OAC alone is insufficient to prevent stent thrombosis. The management of AF patients presenting with an acute coronary syndrome poses similar management complexities. Since AF and coronary artery disease with stent placement are common, it is relatively frequent to treat patients with both these conditions, where triple antithrombotic therapy with Aspirin, Clopidogrel and an OAC would be needed. Dabigatran etexilate, an oral direct thrombin inhibitor, has shown that compared with Warfarin given at a dose of 150 mg twice daily significantly reduces stroke with less intracranial bleeding, and at a dose of 110 mg twice daily has similar efficacy with less bleeding. Although, Dabigatran maintained its overall favorable profile compared with Warfarin in patients on dual antiplatelet therapy, we should always bear in mind for the sake of our AF patients that combining dual antiplatelet therapy with chronic anticoagulation with Dabigatran, as well as with Warfarin, significantly increases bleeding risk. This triple therapy association should be evaluated in the individual patient after carefully balancing bleeding versus thrombotic risk.
White, Peta E; Register-Mihalik, Johna; Donaldson, Alex; Sullivan, S John
2017-01-01
Background/aim Concussion guidelines exist for multiple community sports. Parents are key stakeholders in guideline implementation and in appropriate responses following concussive injury. The purpose of this qualitative investigation was to understand how parents of community-level Australian Football (AF) players experience and perceive concussion guidelines in order to inform the design and implementation of concussion guidelines in community sport. Methods A cross-sectional qualitative approach was adopted to allow for an open and detailed exploration of the views of parents of junior community AF players (ie, those aged <16 years) regarding concussion guidelines of the AF League (AFL)—the national governing body for AF. Participants were 15 parents of junior community AF players from two clubs affiliated with a large regional community AF League. Results The key experiences and perceptions of the parents included appreciation that the guidelines outlined the postconcussion process that should be followed, desires for better understanding of the guidelines by general practitioners (ie, medical doctors) who care for children with concussion, having more readily available information for parents and receiving more formal policy guiding timing of return-to-participation following concussion. Difficulties with the guidelines not addressing delayed presentations of concussion were also frequently mentioned. Conclusions Parents are key stakeholders in concussion prevention and care in community sport. As such, their input should be considered when developing guidelines and resources for community sport. Furthermore, concussion information should be made available to parents in an easily accessible and community-friendly form. PMID:28761707
Dorian, Paul; Cvitkovic, Suzan S; Kerr, Charles R; Crystal, Eugene; Gillis, Anne M; Guerra, Peter G; Mitchell, L Brent; Roy, Denis; Skanes, Allan C; Wyse, D George
2006-04-01
The severity of symptoms caused by atrial fibrillation (AF) is extremely variable. Quantifying the effect of AF on patient well-being is important but there is no simple, commonly accepted measure of the effect of AF on quality of life (QoL). Current QoL measures are cumbersome and impractical for clinical use. To create a simple, concise and readily usable AF severity score to facilitate treatment decisions and physician communication. The Canadian Cardiovascular Society (CCS) Severity of Atrial Fibrillation (SAF) Scale is analogous to the CCS Angina Functional Class. The CCS-SAF score is determined using three steps: documentation of possible AF-related symptoms (palpitations, dyspnea, dizziness/syncope, chest pain, weakness/fatigue); determination of symptom-rhythm correlation; and assessment of the effect of these symptoms on patient daily function and QoL. CCS-SAF scores range from 0 (asymptomatic) to 4 (severe impact of symptoms on QoL and activities of daily living). Patients are also categorized by type of AF (paroxysmal versus persistent/permanent). The CCS-SAF Scale will be validated using accepted measures of patient-perceived severity of symptoms and impairment of QoL and will require 'field testing' to ensure its applicability and reproducibility in the clinical setting. This type of symptom severity scale, like the New York Heart Association Functional Class for heart failure symptoms and the CCS Functional Class for angina symptoms, trades precision and comprehensiveness for simplicity and ease of use at the bedside. A common language to quantify AF severity may help to improve patient care.
NASA Astrophysics Data System (ADS)
Cizdziel, James V.; Tolbert, Candice; Brown, Garry
2010-02-01
A Direct Mercury Analyzer (DMA) based on sample combustion, concentration of mercury by amalgamation with gold, and cold vapor atomic absorption spectrometry (CVAAS) was coupled to a mercury-specific cold vapor atomic fluorescence spectrometer (CVAFS). The purpose was to evaluate combustion-AFS, a technique which is not commercially available, for low-level analysis of mercury in environmental and biological samples. The experimental setup allowed for comparison of dual measurements of mercury (AAS followed by AFS) for a single combustion event. The AFS instrument control program was modified to properly time capture of mercury from the DMA, avoiding deleterious combustion products from reaching its gold traps. Calibration was carried out using both aqueous solutions and solid reference materials. The absolute detection limits for mercury were 0.002 ng for AFS and 0.016 ng for AAS. Recoveries for reference materials ranged from 89% to 111%, and the precision was generally found to be <10% relative standard deviation (RSD). The two methods produced similar results for samples of hair, finger nails, coal, soil, leaves and food stuffs. However, for samples with mercury near the AAS detection limit (e.g., filter paper spotted with whole blood and segments of tree rings) the signal was still quantifiable with AFS, demonstrating the lower detection limit and greater sensitivity of AFS. This study shows that combustion-AFS is feasible for the direct analysis of low levels of mercury in solid samples that would otherwise require time-consuming and contamination-prone digestion.
Magnetic interactions in BiFe0.5Mn0.5O3 films and BiFeO3/BiMnO3 superlattices
NASA Astrophysics Data System (ADS)
Xu, Qingyu; Sheng, Yan; Khalid, M.; Cao, Yanqiang; Wang, Yutian; Qiu, Xiangbiao; Zhang, Wen; He, Maocheng; Wang, Shuangbao; Zhou, Shengqiang; Li, Qi; Wu, Di; Zhai, Ya; Liu, Wenqing; Wang, Peng; Xu, Y. B.; Du, Jun
2015-03-01
The clear understanding of exchange interactions between magnetic ions in substituted BiFeO3 is the prerequisite for the comprehensive studies on magnetic properties. BiFe0.5Mn0.5O3 films and BiFeO3/BiMnO3 superlattices have been fabricated by pulsed laser deposition on (001) SrTiO3 substrates. Using piezoresponse force microscopy (PFM), the ferroelectricity at room temperature has been inferred from the observation of PFM hysteresis loops and electrical writing of ferroelectric domains for both samples. Spin glass behavior has been observed in both samples by temperature dependent magnetization curves and decay of thermo-remnant magnetization with time. The magnetic ordering has been studied by X-ray magnetic circular dichroism measurements, and Fe-O-Mn interaction has been confirmed to be antiferromagnetic (AF). The observed spin glass in BiFe0.5Mn0.5O3 films has been attributed to cluster spin glass due to Mn-rich ferromagnetic (FM) clusters in AF matrix, while spin glass in BiFeO3/BiMnO3 superlattices is due to competition between AF Fe-O-Fe, AF Fe-O-Mn and FM Mn-O-Mn interactions in the well ordered square lattice with two Fe ions in BiFeO3 layer and two Mn ions in BiMnO3 layer at interfaces.
Long range ordered alloys modified by addition of niobium and cerium
Liu, C.T.
1984-08-22
Long range ordered alloys are described having the nominal composition (Fe,Ni,Co)/sub 3/ (V,M) where M is a ductility enhancing metal selected from the group Ti, Zr, Hf with additions of small amounts of cerium and niobium to dramatically enhance the creep properties of the resulting alloys.
Long range ordered alloys modified by addition of niobium and cerium
Liu, Chain T.
1987-01-01
Long range ordered alloys are described having the nominal composition (Fe,Ni,Co).sub.3 (V,M) where M is a ductility enhancing metal selected from the group Ti, Zr, Hf with additions of small amounts of cerium and niobium to drammatically enhance the creep properties of the resulting alloys.
Nanoparticle separation with a miniaturized asymmetrical flow field-flow fractionation cartridge
Müller, David; Cattaneo, Stefano; Meier, Florian; Welz, Roland; de Mello, Andrew J.
2015-01-01
Asymmetrical Flow Field-Flow Fractionation (AF4) is a separation technique applicable to particles over a wide size range. Despite the many advantages of AF4, its adoption in routine particle analysis is somewhat limited by the large footprint of currently available separation cartridges, extended analysis times and significant solvent consumption. To address these issues, we describe the fabrication and characterization of miniaturized AF4 cartridges. Key features of the down-scaled platform include simplified cartridge and reagent handling, reduced analysis costs and higher throughput capacities. The separation performance of the miniaturized cartridge is assessed using certified gold and silver nanoparticle standards. Analysis of gold nanoparticle populations indicates shorter analysis times and increased sensitivity compared to conventional AF4 separation schemes. Moreover, nanoparticulate titanium dioxide populations exhibiting broad size distributions are analyzed in a rapid and efficient manner. Finally, the repeatability and reproducibility of the miniaturized platform are investigated with respect to analysis time and separation efficiency. PMID:26258119
Nanoparticle separation with a miniaturized asymmetrical flow field-flow fractionation cartridge
NASA Astrophysics Data System (ADS)
Müller, David; Cattaneo, Stefano; Meier, Florian; Welz, Roland; deMello, Andrew
2015-07-01
Asymmetrical Flow Field-Flow Fractionation (AF4) is a separation technique applicable to particles over a wide size range. Despite the many advantages of AF4, its adoption in routine particle analysis is somewhat limited by the large footprint of currently available separation cartridges, extended analysis times and significant solvent consumption. To address these issues, we describe the fabrication and characterization of miniaturized AF4 cartridges. Key features of the scale-down platform include simplified cartridge and reagent handling, reduced analysis costs and higher throughput capacities. The separation performance of the miniaturized cartridge is assessed using certified gold and silver nanoparticle standards. Analysis of gold nanoparticle populations indicates shorter analysis times and increased sensitivity compared to conventional AF4 separation schemes. Moreover, nanoparticulate titanium dioxide populations exhibiting broad size distributions are analyzed in a rapid and efficient manner. Finally, the repeatability and reproducibility of the miniaturized platform are investigated with respect to analysis time and separation efficiency.
Zoni Berisso, M; Landolina, M; Ermini, G; Parretti, D; Zingarini, G L; Degli Esposti, L; Cricelli, C; Boriani, G
2017-01-01
Atrial fibrillation (AF) is a relevant item of expenditure for the National Healthcare systems. The aim of the study was to estimate the annual costs of AF in Italy. The Italian Survey of Atrial Fibrillation Management Study enrolled 6.036 patients with AF among 295.906 subjects representative of the Italian population. Data were collected by 233 General Practitioners (GPs) distributed across Italy. Quantities of resources used during the 5 years preceding the ISAF screening were inferred from the survey data and multiplied by the current Italian unit costs of 2015 in order to estimate the mean per patient annual cumulative cost of AF. Patients were subdivided on the basis of the number of hospitalizations, invasive/non-invasive diagnostic tests and invasive therapeutic procedures in 3 different clinical subsets: "low cost", " medium cost" and "high cost clinical scenario". The estimated mean costs per patient per year were 613 €, 891 € and 1213 € for the "Low cost", "Medium cost" and "High Cost Clinical Scenario" respectively. Hospitalizations and inpatient interventional procedures accounted for more than 80% of the cumulative annual costs. The mean annual costs among patients pursuing "Rhythm control" strategy was 956 €. In Italy, the estimated costs of AF per patient per year are lower than those reported in other developed countries and vary widely related to the different characteristics of AF patients. Hospitalizations and interventional procedures are the main drivers of costs. The mean annual cost of AF is mainly influenced by the duration of the period of observation and the patients' characteristics. Measures to reduce hospitalizations are needed.
Generalized internal model robust control for active front steering intervention
NASA Astrophysics Data System (ADS)
Wu, Jian; Zhao, Youqun; Ji, Xuewu; Liu, Yahui; Zhang, Lipeng
2015-03-01
Because of the tire nonlinearity and vehicle's parameters' uncertainties, robust control methods based on the worst cases, such as H ∞, µ synthesis, have been widely used in active front steering control, however, in order to guarantee the stability of active front steering system (AFS) controller, the robust control is at the cost of performance so that the robust controller is a little conservative and has low performance for AFS control. In this paper, a generalized internal model robust control (GIMC) that can overcome the contradiction between performance and stability is used in the AFS control. In GIMC, the Youla parameterization is used in an improved way. And GIMC controller includes two sections: a high performance controller designed for the nominal vehicle model and a robust controller compensating the vehicle parameters' uncertainties and some external disturbances. Simulations of double lane change (DLC) maneuver and that of braking on split- µ road are conducted to compare the performance and stability of the GIMC control, the nominal performance PID controller and the H ∞ controller. Simulation results show that the high nominal performance PID controller will be unstable under some extreme situations because of large vehicle's parameters variations, H ∞ controller is conservative so that the performance is a little low, and only the GIMC controller overcomes the contradiction between performance and robustness, which can both ensure the stability of the AFS controller and guarantee the high performance of the AFS controller. Therefore, the GIMC method proposed for AFS can overcome some disadvantages of control methods used by current AFS system, that is, can solve the instability of PID or LQP control methods and the low performance of the standard H ∞ controller.
Search for the Heisenberg spin glass on rewired square lattices with antiferromagnetic interaction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Surungan, Tasrief, E-mail: tasrief@unhas.ac.id; Bansawang, B.J.; Tahir, Dahlang
Spin glass (SG) is a typical magnetic system with frozen random spin orientation at low temperatures. The system exhibits rich physical properties, such as infinite number of ground states, memory effect, and aging phenomena. There are two main ingredients considered to be pivotal for the existence of SG behavior, namely, frustration and randomness. For the canonical SG system, frustration is led by the presence of competing interaction between ferromagnetic (FM) and antiferromagnetic (AF) couplings. Previously, Bartolozzi et al. [Phys. Rev. B73, 224419 (2006)], reported the SG properties of the AF Ising spins on scale free network (SFN). It is amore » new type of SG, different from the canonical one which requires the presence of both FM and AF couplings. In this new system, frustration is purely caused by the topological factor and its randomness is related to the irregular connectvity. Recently, Surungan et. al. [Journal of Physics: Conference Series, 640, 012001 (2015)] reported SG bahavior of AF Heisenberg model on SFN. We further investigate this type of system by studying an AF Heisenberg model on rewired square lattices. We used Replica Exchange algorithm of Monte Carlo Method and calculated the SG order parameter to search for the existence of SG phase.« less
Kant, Nasir Ali; Dar, Mohamad Rafiq; Khanday, Farooq Ahmad
2015-01-01
The output of every neuron in neural network is specified by the employed activation function (AF) and therefore forms the heart of neural networks. As far as the design of artificial neural networks (ANNs) is concerned, hardware approach is preferred over software one because it promises the full utilization of the application potential of ANNs. Therefore, besides some arithmetic blocks, designing AF in hardware is the most important for designing ANN. While attempting to design the AF in hardware, the designs should be compatible with the modern Very Large Scale Integration (VLSI) design techniques. In this regard, the implemented designs should: only be in Metal Oxide Semiconductor (MOS) technology in order to be compatible with the digital designs, provide electronic tunability feature, and be able to operate at ultra-low voltage. Companding is one of the promising circuit design techniques for achieving these goals. In this paper, 0.5 V design of Liao's AF using sinh-domain technique is introduced. Furthermore, the function is tested by implementing inertial neuron model. The performance of the AF and inertial neuron model have been evaluated through simulation results, using the PSPICE software with the MOS transistor models provided by the 0.18-μm Taiwan Semiconductor Manufacturer Complementary Metal Oxide Semiconductor (TSM CMOS) process.
Matsumoto, Tomoko; Tsurumoto, Toshiyuki; Baba, Hideo; Osaki, Makoto; Enomoto, Hiroshi; Yonekura, Akihiko; Shindo, Hiroyuki; Miyata, Toshio
2007-12-01
Advanced glycation endproducts (AGEs) are the products of non-enzymatic glycation and oxidation of proteins and lipids. Low-turnover tissues such as articular cartilage seem to be susceptible to the accumulation of AGEs, which might lead to cartilage degradation. Recently, a non-invasive method for measuring skin AGE accumulation was developed by using the Autofluorescence Reader (AFR). To examine the usefulness of measuring skin AGE in patients with bone and joint diseases, we examined autofluorescence (AF) levels in skin of patients with osteoarthritis (OA), rheumatoid arthritis (RA), and dialysis-related spondyloarthropathy (DRSA). Ninety-three patients with RA, 24 patients with OA, and 29 patients with DRSA were examined, and 43 healthy volunteers were used as controls. Skin AF was assessed on the lower arm with the AGE-Reader. Mean AF was significantly higher in the patients with RA (median 2.13 and range 1.25-2.94) or with DRSA (median 2.21 and range 1.29-3.88) than in the patients with OA (median 1.63 and range 1.07-2.31) or in the controls (median 1.74 and range 1.10-2.46). There was no significant difference between OA and the controls, or between RA and DRSA. These findings suggest that differences of AGE accumulation in the skin might reflect the different pathologies of these diseases.
Uldry, Laurent; Virag, Nathalie; Jacquemet, Vincent; Vesin, Jean-Marc; Kappenberger, Lukas
2010-12-01
While successful termination by pacing of organized atrial tachycardias has been observed in patients, rapid pacing of AF can induce a local capture of the atrial tissue but in general no termination. The purpose of this study was to perform a systematic evaluation of the ability to capture AF by rapid pacing in a biophysical model of the atria with different dynamics in terms of conduction velocity (CV) and action potential duration (APD). Rapid pacing was applied during 30 s at five locations on the atria, for pacing cycle lengths in the range 60-110% of the mean AF cycle length (AFCL(mean)). Local AF capture could be achieved using rapid pacing at pacing sites located distal to major anatomical obstacles. Optimal pacing cycle lengths were found in the range 74-80% AFCL(mean) (capture window width: 14.6 ± 3% AFCL(mean)). An increase/decrease in CV or APD led to a significant shrinking/stretching of the capture window. Capture did not depend on AFCL, but did depend on the atrial substrate as characterized by an estimate of its wavelength, a better capture being achieved at shorter wavelengths. This model-based study suggests that a proper selection of the pacing site and cycle length can influence local capture results and that atrial tissue properties (CV and APD) are determinants of the response to rapid pacing.
Yarlagadda, Bharath; Turagam, Mohit K; Dar, Tawseef; Jangam, Pragna; Veerapaneni, Vaishnavi; Atkins, Donita; Bommana, Sudharani; Friedman, Paul; Deshmukh, Abhishek J; Doshi, Rahul; Reddy, Vivek Y; Dukkipati, Srinivas R; Natale, Andrea; Lakkireddy, Dhanunjaya
2018-03-01
Atrioventricular node (AVN) ablation and permanent pacing is an established strategy for rate control in the management of symptomatic atrial fibrillation (AF). Leadless pacemakers (LPs) can overcome some of the short-term and long-term limitations of conventional transvenous pacemakers (CTPs). The purpose of this study was to compare the feasibility and safety of LP with those of single-chamber CTP in patients with AF undergoing AVN ablation. We conducted a multicenter observational study of patients undergoing AVN ablation and pacemaker implantation (LP vs single-chamber CTP) between February 2014 and November 2016. The primary efficacy end points were acceptable sensing (R wave ≥5.0 mV) and pacing thresholds (≤2.0 V at 0.4 ms) at follow-up. Safety end points included device-related major and minor (early ≤1 month, late >1 month) adverse events. A total of 127 patients with LP (n = 60) and CTP (n = 67) were studied. The median follow-up was 12 months (interquartile range 12-18 months). Ninety-five percent of the LP group and 97% of the CTP group met the primary efficacy end point at follow-up (57 of 60 vs 65 of 67; P = .66). There was 1 major adverse event (loss of pacing and sensing) in the LP group and 2 (lead dislodgement) in the CTP group (1 of 60 vs 2 of 67; P = 1.00). There were 6 minor adverse events (5 early and 1 late) in the LP group and 3 (early) in the CTP group (6 of 60 vs 3 of 67; P = .30). Our results demonstrate the feasibility and safety of LP compared with CTP in patients undergoing AVN ablation for AF. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Vollmar, A C; Fox, P R
2016-01-01
Dilated cardiomyopathy (DCM) is a common cause of morbidity and mortality in the Irish Wolfhound (IW). However, the benefit of medical treatment in IW dogs with preclinical DCM, atrial fibrillation (AF), or both has not been demonstrated. Compare the time to develop congestive heart failure (CHF) or sudden death in IW dogs with preclinical DCM, AF, or both receiving monotherapy with pimobendan, methyldigoxin, or benazepril hydrochloride. Seventy-five client-owned IW dogs. Irish Wolfhound dogs were prospectively randomized to receive pimobendan (Vetmedin®), benazepril HCl (Fortekor®), or methyldigoxin (Lanitop®) monotherapy in a 1:1:1 ratio in a blinded clinical trial. The prospectively defined composite primary endpoint was onset of CHF or sudden death. To assure stringent evaluation of treatment effect, data from dogs complying with the study protocol were analyzed. Sixty-six IW fulfilling the study protocol included 39 males, 27 females; median (interquartile range) age, 4.0 years (3.0-5.0 years) and weight, 70.0 kg (63.0-75.0 kg). Primary endpoint was reached in 5 of 23 (21.7%) IW receiving pimobendan, 11 of 22 (50.0%) receiving benazepril HCl, and 9 of 21 (42.9%) receiving methyldigoxin. Median time to primary endpoint was significantly longer for pimobendan (1,991 days; 65.4 months) compared to methyldigoxin (1,263 days; 41.5 months; P = .031) or benazepril HCl-(997 days; 32.8 months; P = .008) treated dogs. In IW dogs with preclinical DCM, AF or both, pimobendan monotherapy significantly prolonged time to onset of CHF or sudden death than did monotherapy with benazepril HCl or methyldigoxin. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
NASA Astrophysics Data System (ADS)
Akif Sarıkaya, Mehmet; Yıldırım, Cengiz; Çiner, Attila
2014-05-01
The Ecemiş Fault Zone is the southernmost segment of the Central Anatolian Fault Zone. The tectonic trough of the fault zone defines the boundary between the Central and Eastern Taurides Ranges. The presence of faulted alluvial fans and colluvium within this trough provide favorable conditions to unravel the Late Quaternary slip-rate of the fault zone by cosmogenic surface exposure dating. In this context, we focused on the main strand of the fault zone and also on the Cevizlik Fault that delimits the mountain front of the Aladaǧlar, Eastern Taurides. Geomorphic mapping and topographic surveying indicate four different alluvial fan levels deposited along the main strand. Our topographic survey reveals 60±5 m horizontal and 18±2 m vertical displacement of the oldest fan surface (AF1) associated with the main strand of the fault zone. We dated the surface of the AF1 with 13 cosmogenic 36Cl samples. Our results indicate that the AF1 surface was abandoned maximum 105.3±1.5 ka ago. Accordingly, we propose 0.57±0.05 mm/yr horizontal and 0.17±0.02 mm/yr vertical mean slip-rates since 100 ka for the main strand. On the other hand, we measured 20±2 m vertical displacement on the colluvium along the Cevizlik Fault. The surface exposure age of the colluvium yielded 21.9±0.3 ka that translates to 0.91±0.09 mm/yr vertical slip-rate for the Cevizlik Fault. Our results reveal significant Quaternary deformation, and low strain rates might indicate very long earthquake recurrence intervals along the fault zone.
Johnson, Natalie M.; Qian, Guoqing; Xu, Li; Tietze, Danielle; Marroquin-Cardona, Alicia; Robinson, Abraham; Rodriguez, Melanie; Kaufman, Linda; Cunningham, Kyle; Wittmer, James; Guerra, Fernando; Donnelly, Kirby C.; Williams, Jonathan H.; Wang, Jia-Sheng; Phillips, Timothy D.
2010-01-01
The incidence of hepatocellular carcinoma (HCC) is significantly elevated in a Hispanic community in Bexar County, Texas. Chronic exposure to dietary aflatoxins (AFs) is a major risk factor for HCC; increased risk has been linked to polycyclic aromatic hydrocarbon (PAH) co-exposure and hepatitis virus infection. The aims of this study were to assess AF and PAH exposures, investigate dietary factors that may contribute to increased AF exposure, and determine the prevalence of hepatitis virus infection in Bexar Co. Blood and urine samples were collected from 184 volunteers for biomarker analyses and hepatitis screening. Serum AFB1-lysine adduct, urinary AFM1 and 1-hydroxypyrene (1-OHP) levels were measured using high-performance liquid chromatography. The average AFB1-lysine adduct level detected in 20.6% of serums was 3.84 ± 3.11 pg/mg albumin (range 1.01-16.57 pg/mg). AFM1 was detected in 11.7% of urines, averaging 223.85 ± 250.56 pg/mg creatinine (range 1.89-935.49 pg/mg). AFM1 detection was associated with increased consumption of corn tortillas (p = 0.009), nuts (p = 0.033) and rice (p = 0.037). A significant difference was observed between mean 1-OHP values of non-smokers (0.07 ± 0.13) and smokers (0.80 ± 0.68) μmol/mol creatinine (p < 0.01). A high hepatitis C virus positivity rate (7.1%) was observed. Findings suggest that the incidence and level of AF and PAH exposure was less than that observed in a high-risk population; however, participants consuming higher amounts of foods prone to AF contamination may be more vulnerable to exposure and interactions with other environmental/biological factors (i.e., HCV). PMID:20870273
Guo, Meihua; Wang, Wenjing; Hai, Xin; Zhou, Jin
2017-10-25
Arsenic trioxide (ATO) has been successfully used in the treatment of acute promyelocytic leukemia (APL). To clarify the arsenic species in APL patients, high performance liquid chromatography-hydride generation-atomic fluorescence spectrometry (HPLC-HG-AFS) and HG-AFS methods were developed and validated to quantify the plasma concentrations of inorganic arsenic (As(III) and As(V)) and methylated metabolites (MMA and DMA), and the total amounts of arsenic in blood cells and plasma. Blood cells and plasma were digested with mixtures of HNO 3 H 2 O 2 and analyzed by HG-AFS. For arsenic speciation, plasma samples were prepared with perchloric acid to precipitate protein. The supernatant was separated on an anion-exchange column within 6min with isocratic elution using 13mM CH 3 COONa, 3mM NaH 2 PO 4 , 4mM KNO 3 and 0.2mM EDTA-2Na. The methods provided linearity range of 0.2-20ng/mL for total arsenic and 2.0-50ng/mL for four arsenic species. The developed methods for total arsenic and arsenic species determination were precise and accurate. The spiked recoveries ranged from 81.2%-108.6% and the coefficients of variation for intra- and inter-batch precision were less than 9.3% and 12.5%, respectively. The developed methods were applied successfully for the assay of total arsenic and arsenic species in 5 APL patients. The HPLC-HG-AFS may be a good alternative for arsenic species determination in APL patients with its simplicity and low-cost in comparison with HPLC-ICP-MS. Copyright © 2017 Elsevier B.V. All rights reserved.
Dorian, Paul; Guerra, Peter G; Kerr, Charles R; O'Donnell, Suzan S; Crystal, Eugene; Gillis, Anne M; Mitchell, L Brent; Roy, Denis; Skanes, Allan C; Rose, M Sarah; Wyse, D George
2009-06-01
Atrial fibrillation (AF) is commonly associated with impaired quality of life. There is no simple validated scale to quantify the functional illness burden of AF. The Canadian Cardiovascular Society Severity in Atrial Fibrillation (CCS-SAF) scale is a bedside scale that ranges from class 0 to 4, from no effect on functional quality of life to a severe effect on life quality. This study was performed to validate the scale. In 484 patients with documented AF (62.2+/-12.5 years of age, 67% men; 62% paroxysmal and 38% persistent/permanent), the SAF class was assessed and 2 validated quality-of-life questionnaires were administered: the SF-36 generic scale and the disease-specific AFSS (University of Toronto Atrial Fibrillation Severity Scale). There is a significant linear graded correlation between the SAF class and measures of symptom severity, physical and emotional components of quality of life, general well-being, and health care consumption related to AF. Patients with SAF class 0 had age- and sex-standardized SF-36 scores of 0.15+/-0.16 and -0.04+/-0.31 (SD units), that is, units away from the mean population score for the mental and physical summary scores, respectively. For each unit increase in SAF class, there is a 0.36 and 0.40 SD unit decrease in the SF-36 score for the physical and mental components. As the SAF class increases from 0 to 4, the symptom severity score (range, 0 to 35) increases from 4.2+/-5.0 to 18.4+/-7.8 (P<0.0001). The CCS-SAF scale is a simple semiquantitative scale that closely approximates patient-reported subjective measures of quality of life in AF and may be practical for clinical use.
Capucci, Alessandro; Piangerelli, Luca; Ricciotti, Jenny; Gabrielli, Domenico; Guerra, Federico
2016-11-01
Atrial fibrillation (AF) affects ∼2% of the total population. In order to prevent AF recurrences, many anti-arrhythmic drugs are currently available, but most of them are burdened by serious side effects and suboptimal efficacy. The aim of the present study was to test efficacy and safety of a combination of flecainide and metoprolol in preventing AF clinical recurrences. This study is a monocentric, prospective, randomized, open-blinded trial on 173 patients with a recent episode of paroxysmal or persistent AF. Patients were randomized into group A (flecainide + metoprolol; n = 80), group B (flecainide only; n = 72), or group C (metoprolol only; n = 21). Main exclusion criteria were recent acute coronary syndrome, heart failure New York Heart Association class III-IV, left ventricular ejection fraction <0.40, atrioventricular conduction disorders, and severe bradycardia. Primary endpoint was symptomatic recurrence over 1-year follow-up. Secondary endpoint was quality of life (QoL) over 1-year follow-up, as assessed by the SF-36 and Atrial Fibrillation Severity Scale questionnaires. Combination therapy with flecainide and metoprolol significantly reduced recurrences at 1-year follow-up when compared with flecainide alone in the whole population (66.7 vs. 46.8%; P < 0.001) and in patients with persistent AF (71.1 vs. 43.6%; P = 0.025) while adding beta-blocker therapy to paroxysmal AF showed no benefit over IC anti-arrhythmic drug-only. Patients randomized to combination therapy experienced a significant improvement of QoL when compared with those assigned to a flecainide-only regimen irrespective of AF type. Flecainide-metoprolol combination therapy improves effectiveness of rhythm control in persistent symptomatic AF and increases tolerability, with a concomitant reduction of side effects and a better compliance. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Dudas, Bertalan; Rose, Michael; Cornelli, Umberto; Hanin, Israel
2005-02-01
Glycosaminoglycans (GAGs) play a pivotal role in the pathogenesis of Alzheimer's disease (AD). Although, as we have shown earlier, a low molecular weight GAG, C3, protects against ethylcholine aziridinium (AF64A)-induced cholinergic damage, and against A(beta)-induced tau-2-immunoreactivity (IR), the mechanism of the neuroprotective effect of GAGs is not yet known. Several clues exist. Previous studies in rats revealed that continuous NGF infusion (icv) after AF64A injection increases septal ChAT and AChE activities. Moreover, C3 increases axonal outgrowth in the rat hippocampus, raising the possibility of a NGF-receptor mediated neuroprotection. Furthermore, it has been reported that NGF expression is increased in the septum following AF64A administration. To study the question regarding the mechanism of neuroprotective action of GAGs, AF64A, a selective cholinotoxin, was administered stereotaxically, bilaterally, into the lateral ventricles of Fischer albino male rats (1 nmol/2 microl/side). In order to establish the effect of C3 on the expression of the NGF receptor-IR elements, C3 was administered orally (25 mg/kg, once a day), by gavage, 7 days before, and 7 days after the AF64A injection. NGF receptor immunohistochemistry revealed that AF64A induced the appearance of NGF-receptor-IR axonal varicosities in the rat medial septum. These varicose fibers were attenuated by 14 days' administration of C3. The possible explanation of our data may be that C3 increases NGF synthesis in the lateral septum. The increased level of NGF could suppress the increased, AF64A-induced NGF receptor expression in the medial septal nucleus. These results further accentuate our earlier observations that C3 may have potential as a therapeutic agent in AD and other neurodegenerative disorders.
Direct His bundle pacing post AVN ablation.
Lakshmanadoss, Umashankar; Aggarwal, Ashim; Huang, David T; Daubert, James P; Shah, Abrar
2009-08-01
Atrioventricular nodal (AVN) ablation with concomitant pacemaker implantation is one of the strategies that reduce symptoms in patients with atrial fibrillation (AF). However, the long-term adverse effects of right ventricular (RV) apical pacing have led to the search for alternating sites of pacing. Biventricular pacing produces a significant improvement in functional capacity over RV pacing in patients undergoing AVN ablation. Another alternative site for pacing is direct His bundle to reduce the adverse outcome of RV pacing. Here, we present a case of direct His bundle pacing using steerable lead delivery system in a patient with symptomatic paroxysmal AF with concurrent AVN ablation.
Romero, Roberto; Miranda, Jezid; Chaiworapongsa, Tinnakorn; Chaemsaithong, Piya; Gotsch, Francesca; Dong, Zhong; Ahmed, Ahmed I.; Yoon, Bo Hyun; Hassan, Sonia; Kim, Chong J.; Korzeniewski, Steven J.; Yeo, Lami
2014-01-01
Objective The major challenges in using amniotic fluid (AF) cultivation techniques to diagnose microbial invasion of the amniotic cavity (MIAC) are: 1) several days are typically required to obtain results, and 2) many organisms implicated in the pathogenesis of human disease are difficult to culture. Here, we compare the performance of AF culture with a novel technique for the diagnosis of MIAC that can provide results within eight hours by combining broad-range real-time polymerase chain reaction with electrospray ionization mass spectrometry (PCR/ESI-MS) to identify and quantify genomic material from bacteria and viruses in AF. Methods AF samples obtained by transabdominal amniocentesis from 142 women with preterm labor (PTL) and intact membranes were analyzed using cultivation techniques (aerobic, anaerobic and genital mycoplasmas) as well as PCR/ESI-MS. The prevalence and relative magnitude of intra-amniotic inflammation [AF Interleukin 6 (IL-6) concentration ≥ 2.6 ng/mL], acute histologic chorioamnionitis, spontaneous preterm delivery, and perinatal mortality were examined according to the results of these two tests. Results 1) The prevalence of MIAC in patients with preterm labor and intact membranes was 7% using standard cultivation techniques and 12% using PCR/ESI-MS; 2) seven of ten patients with positive AF culture also had positive PCR/ESI-MS [≥17 genome equivalents per PCR reaction well (GE/well)] 3) patients with positive PCR/ESI-MS (≥17 GE/well) and negative AF cultures had significantly higher rates of intra-amniotic inflammation and histologic acute chorioamnionitis, shorter intervals to delivery [median (interquartile range-IQR)], and offspring at higher risk of perinatal mortality, than women with both tests negative [90% (9/10) vs. 32% (39/122); (p<0.001); 70% (7/10) vs. 35% (39/112); (p=0.04); 1 (IQR: <1 – 2) days vs. 25 (IQR: 5 – 51) days; (p=0.002); OR: 5.6; 95% CI: 1.4 – 22, respectively]; 5) there were no significant differences in these factors between patients with positive PCR/ESI-MS (≥17 GE/well) who had negative AF cultures compared to those with positive AF cultures; and 6) PCR/ESI-MS detected genomic material from viruses in two patients (1.4%). Conclusion 1) Rapid diagnosis of intra-amniotic infection is possible using PCR/ESI-MS, which can provide results within 8 hours; 2) the combined use of biomarkers of inflammation and PCR/ESI-MS allows for the rapid identification of specific bacteria and viruses in women with preterm labor and intra-amniotic infection; and 3) this approach may allow for administration of timely and specific interventions to reduce morbidity attributed to infection-induced preterm birth. PMID:24417618
microRNA regulatory mechanism by which PLLA aligned nanofibers influence PC12 cell differentiation
NASA Astrophysics Data System (ADS)
Yu, Yadong; Lü, Xiaoying; Ding, Fei
2015-08-01
Objective. Aligned nanofibers (AFs) are regarded as promising biomaterials in nerve tissue engineering. However, a full understanding of the biocompatibility of AFs at the molecular level is still challenging. Therefore, the present study focused on identifying the microRNA (miRNA)-mediated regulatory mechanism by which poly-L-lactic acid (PLLA) AFs influence PC12 cell differentiation. Approach. Firstly, the effects of PLLA random nanofibers (RFs)/AFs and PLLA films (control) on the biological responses of PC12 cells that are associated with neuronal differentiation were examined. Then, SOLiD sequencing and cDNA microarray were employed to profile the expressions of miRNAs and mRNAs. The target genes of the misregulated miRNAs were predicted and compared with the mRNA profile data. Functions of the matched target genes (the intersection between the predicted target genes and the experimentally-determined, misregulated genes) were analyzed. Main results. The results revealed that neurites spread in various directions in control and RF groups. In the AF group, most neurites extended in parallel with each other. The glucose consumption and lactic acid production in the RF and AF groups were higher than those in the control group. Compared with the control group, 42 and 94 miRNAs were significantly dysregulated in the RF and AF groups, respectively. By comparing the predicted target genes with the mRNA profile data, five and 87 matched target genes were found in the RF and AF groups, respectively. Three of the matched target genes in the AF group were found to be associated with neuronal differentiation, whereas none had this association in the RF group. The PLLA AFs induced the dysregulation of miRNAs that regulate many biological functions, including axonal guidance, lipid metabolism and long-term potentiation. In particular, two miRNA-matched target gene-biological function modules associated with neuronal differentiation were identified as follows: (1) miR-23b, miR-18a, miR-107 and miR-103 regulate the Rras2 and Nf1 gene and thereby, affect cytoskeleton regulation and MAPK pathway; (2) miR-92a, miR-339-5p, miR-25, miR-125a-5p, miR-351 and miR-19b co-regulate the Pafah1b1 gene, affecting PC12 cell migration and differentiation. Significance. This work demonstrates a bioinformatic approach to accomplish miRNA-mRNA profile integrative analysis and provides more insights for understanding the regulatory mechanism of miRNA in AFs affecting neuronal differentiation. These findings will be greatly beneficial for the application and design of AFs in nerve tissue engineering.
Themistoclakis, Sakis; Tritto, Massimo; Bertaglia, Emanuele; Berto, Patrizia; Bongiorni, Maria Grazia; Catanzariti, Domenico; De Fabrizio, Giuseppe; De Ponti, Roberto; Grimaldi, Massimo; Pandozi, Claudio; Tondo, Claudio; Gulizia, Michele
2011-11-01
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and significantly impact patients' quality of life, morbidity and mortality. The number of affected patients is expected to increase as well as the costs associated with AF management, mainly driven by hospitalizations. Over the last decade, catheter ablation techniques targeting pulmonary vein isolation have demonstrated to be effective in treating AF and preventing AF recurrence. This Health Technology Assessment report of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) aims to define the current role of catheter ablation of AF in terms of effectiveness, efficiency and appropriateness. On the basis of an extensive review of the available literature, this report provides (i) an overview of the epidemiology, clinical impact and socio-economic burden of AF; (ii) an evaluation of therapeutic options other than catheter ablation of AF; and (iii) a detailed presentation of clinical outcomes and cost-benefit ratio associated with catheter ablation. The costs of catheter ablation of AF in Italy were obtained using a bottom-up analysis of a resource utilization survey of 52 hospitals that were considered a representative sample, including 4 Centers that contributed with additional unit cost information in a separate questionnaire. An analysis of budget impact was also performed to evaluate the impact of ablation on the management costs of AF. Results of this analysis show that (1) catheter ablation is effective, safe and superior to antiarrhythmic drug therapy in maintaining sinus rhythm; (2) the cost of an ablation procedure in Italy typically ranges from €8868 to €9455, though current reimbursement remains insufficient, covering only about 60% of the costs; (3) the costs of follow-up are modest (about 8% of total costs); (4) assuming an adjustment of reimbursement to the real cost of an ablation procedure and a 5-10% increase in the annual rate of ablation procedures, after approximately 5-6 years this would result in significant incremental savings for the Italian Healthcare System. In conclusion, catheter ablation of AF is a cost-effective procedure that is inadequately reimbursed in Italy. Insufficient reimbursement may serve as disincentive to perform AF ablation, thereby limiting patient access to this treatment. Considering the healthcare system perspective, higher initial costs for ablation procedures in the short term may be offset by cost savings mainly associated with decreased hospitalizations over time.
Remanent magnetic properties of unbrecciated eucrites
NASA Technical Reports Server (NTRS)
Cisowski, Stanley M.
1991-01-01
This study examines the remanent magnetic properties of five unbrecciated eucrites, ranging from the coarse-grained cumulate Moore County to the quenched melt rock ALH 81001 in order to assess the strength of the magnetic field associated with their parent body during their formation. Two of the meteorites are judged as unlikely to have preserved their primary thermal remanence because of large variations in subsample remanence intensity and direction (Ibitira), and lack of NRM resistance to AF and thermal demagnetization (PCA 82502). The lack of a strong (greater than 0.01 mT) magnetizing field during their cooling on the eucrite parent body is inferred from the low normalized NRM intensities for subsamples of ALH 81001 and Yamato 791195.
Specific considerations with the automatic implantable atrial defibrillator.
Jung, W; Wolpert, C; Esmailzadeh, B; Spehl, S; Herwig, S; Schumacher, B; Lewalter, T; Omran, H; Kirchhoff, P G; Lüderitz, B
1998-08-01
Internal atrial defibrillation has been evaluated as an alternative approach to the external technique for more than two decades. Previous studies in animals and humans have shown that internal atrial defibrillation is feasible with relatively low energies. The promising results achieved with internal atrial defibrillation have facilitated the development of an implantable atrial defibrillator (IAD). For any new therapy, it is imperative to demonstrate safety, efficacy, tolerability with improvement in quality of life, and cost-effectiveness compared with therapeutic options already available. Maintenance of sinus rhythm or prolonged duration in arrhythmia-free intervals should be demonstrated clearly with an IAD. Initial clinical experience with the Metrix system indicates stable atrial defibrillation thresholds, appropriate R wave synchronization markers, no shock-induced ventricular proarrhythmia, and excellent detection of atrial fibrillation (AF) with a specificity of 100%. Ventricular proarrhythmia has not been reported for correctly R wave synchronized low-energy shocks when closely coupled to RR intervals, and long-short cycles are avoided. Preliminary experience with the Metrix system suggests that the IAD may offer a therapeutic alternative for a subgroup of patients with drug-refractory, symptomatic, long-lasting, and infrequent episodes of AF. Further efforts must be undertaken to reduce the patient discomfort associated with internal atrial defibrillation in an attempt to make this new therapy acceptable to a larger patient population with AF.
Boersma, Lucas V A; Schmidt, Boris; Betts, Tim R; Sievert, Horst; Tamburino, Corrado; Teiger, Emmanuel; Stein, Kenneth M; Bergmann, Martin W
2016-09-01
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and the rate of ischemic stroke attributed to non-valvular AF is estimated at 5% per year. Several multi-center studies established left atrial appendage closure as a safe and effective alternative to oral anticoagulation, but there is a need for additional real world data. The purpose of this observational, prospective, single-arm, multicenter clinical study is to compile real-world clinical outcome data for WATCHMAN™ LAA (left atrial appendage) Closure Technology. One thousand subjects at up to 70 institutions in Europe, the Middle East, and Russia will be enrolled. Patients will be followed for 2 years after WATCHMAN implantation, according to standard medical practice. Primary endpoints include procedural and long-term data including stroke/embolism, bleeding, and death. This article presents the background of the LAAC device and describes the design of the study. Results for peri-procedural analyses are expected toward the end of 2015; long-term follow-up data are expected in the latter half of 2017. The EWOLUTION study will formally expand knowledge of LAA closure into a broader real world setting. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis.
Welton, Nicky J; McAleenan, Alexandra; Thom, Howard Hz; Davies, Philippa; Hollingworth, Will; Higgins, Julian Pt; Okoli, George; Sterne, Jonathan Ac; Feder, Gene; Eaton, Diane; Hingorani, Aroon; Fawsitt, Christopher; Lobban, Trudie; Bryden, Peter; Richards, Alison; Sofat, Reecha
2017-05-01
Atrial fibrillation (AF) is a common cardiac arrhythmia that increases the risk of thromboembolic events. Anticoagulation therapy to prevent AF-related stroke has been shown to be cost-effective. A national screening programme for AF may prevent AF-related events, but would involve a substantial investment of NHS resources. To conduct a systematic review of the diagnostic test accuracy (DTA) of screening tests for AF, update a systematic review of comparative studies evaluating screening strategies for AF, develop an economic model to compare the cost-effectiveness of different screening strategies and review observational studies of AF screening to provide inputs to the model. Systematic review, meta-analysis and cost-effectiveness analysis. Primary care. Adults. Screening strategies, defined by screening test, age at initial and final screens, screening interval and format of screening {systematic opportunistic screening [individuals offered screening if they consult with their general practitioner (GP)] or systematic population screening (when all eligible individuals are invited to screening)}. Sensitivity, specificity and diagnostic odds ratios; the odds ratio of detecting new AF cases compared with no screening; and the mean incremental net benefit compared with no screening. Two reviewers screened the search results, extracted data and assessed the risk of bias. A DTA meta-analysis was perfomed, and a decision tree and Markov model was used to evaluate the cost-effectiveness of the screening strategies. Diagnostic test accuracy depended on the screening test and how it was interpreted. In general, the screening tests identified in our review had high sensitivity (> 0.9). Systematic population and systematic opportunistic screening strategies were found to be similarly effective, with an estimated 170 individuals needed to be screened to detect one additional AF case compared with no screening. Systematic opportunistic screening was more likely to be cost-effective than systematic population screening, as long as the uptake of opportunistic screening observed in randomised controlled trials translates to practice. Modified blood pressure monitors, photoplethysmography or nurse pulse palpation were more likely to be cost-effective than other screening tests. A screening strategy with an initial screening age of 65 years and repeated screens every 5 years until age 80 years was likely to be cost-effective, provided that compliance with treatment does not decline with increasing age. A national screening programme for AF is likely to represent a cost-effective use of resources. Systematic opportunistic screening is more likely to be cost-effective than systematic population screening. Nurse pulse palpation or modified blood pressure monitors would be appropriate screening tests, with confirmation by diagnostic 12-lead electrocardiography interpreted by a trained GP, with referral to a specialist in the case of an unclear diagnosis. Implementation strategies to operationalise uptake of systematic opportunistic screening in primary care should accompany any screening recommendations. Many inputs for the economic model relied on a single trial [the Screening for Atrial Fibrillation in the Elderly (SAFE) study] and DTA results were based on a few studies at high risk of bias/of low applicability. Comparative studies measuring long-term outcomes of screening strategies and DTA studies for new, emerging technologies and to replicate the results for photoplethysmography and GP interpretation of 12-lead electrocardiography in a screening population. This study is registered as PROSPERO CRD42014013739. The National Institute for Health Research Health Technology Assessment programme.
Coexistence of long-range cycloidal order and spin-cluster glass state in the multiferroic BaYFeO4.
Ghara, Somnath; Sundaresan, A
2018-06-20
We report the presence of spin glass state below the cycloidal spin ordering in the multiferroic BaYFeO 4 . This compound is known to crystallize in an orthorhombic structure with a centrosymmetric space group Pnma and exhibits two successive antiferromagnetic phase transitions. Upon cooling, it undergoes a spin density wave (SDW)-like antiferromagnetic ordering at T N1 ~ 48 K and a cycloidal ordering at T N2 ~ 35 K. Using dc magnetic memory effect and magnetization relaxation studies, we have shown that this oxide undergoes a reentrant spin glass transition below T * ~ 17 K. Our analysis suggests the presence of spin clusters in the glassy state. The coexistence of spin-cluster glass and long-range cycloidal ordered states results in an exchange bias effect at 2 K. The origin of the glassy state has been attributed to freezing of some Fe 3+ moments, which do not participate in the long-range ordering.
Coexistence of long-range cycloidal order and spin-cluster glass state in the multiferroic BaYFeO4
NASA Astrophysics Data System (ADS)
Ghara, Somnath; Sundaresan, A.
2018-06-01
We report the presence of spin glass state below the cycloidal spin ordering in the multiferroic BaYFeO4. This compound is known to crystallize in an orthorhombic structure with a centrosymmetric space group Pnma and exhibits two successive antiferromagnetic phase transitions. Upon cooling, it undergoes a spin density wave (SDW)-like antiferromagnetic ordering at T N1 ~ 48 K and a cycloidal ordering at T N2 ~ 35 K. Using dc magnetic memory effect and magnetization relaxation studies, we have shown that this oxide undergoes a reentrant spin glass transition below T * ~ 17 K. Our analysis suggests the presence of spin clusters in the glassy state. The coexistence of spin-cluster glass and long-range cycloidal ordered states results in an exchange bias effect at 2 K. The origin of the glassy state has been attributed to freezing of some Fe3+ moments, which do not participate in the long-range ordering.
The impact of cardiac rhythm on the mitral valve area and gradient in patients with mitral stenosis.
Arı, Hasan; Arı, Selma; Karakuş, Alper; Camcı, Sencer; Doğanay, Kübra; Tütüncü, Ahmet; Melek, Mehmet; Bozat, Tahsin
2017-08-01
The aim of this study was to evaluate the effect of cardiac rhythm on the echocardiographic mitral valve area (MVA) and transmitral gradient calculation in relation to net atrioventricular compliance (Cn). Patients (n=22) with mild or moderate pure rheumatic mitral stenosis (MS) (MVA <2 cm2 and MVA >1 cm2) and atrial fibrillation (AF) were evaluated. All patients underwent transthoracic electrical DC cardioversion under amiodarone treatment. Nineteen of the 22 patients were successfully converted to sinus rhythm (SR). The patients were evaluated with transthoracic echocardiography before and two to three days after DC cardioversion. In order to deal with variable R-R intervals, the measurements were averaged on five to eight consecutive beats in AF. Cn was calculated with a previously validated equation [Cn (mL/mm Hg)=1.270 x MVA/E-wave downslope]. The Cn difference between AF and SR was calculated as follows: [(AF Cn-SR Cn)/AF Cn] x 100. The percentage gradient (mean or maximal) difference between AF and SR was calculated as follows: [AF gradient (mean or maximal) - SR gradient (mean or maximal)]/[AF gradient (mean or maximal)] x 100. The MVA was lower (MVA planimetric; 1.62±0.29 vs. 1.54±0.27; p=.003, MVA PHT; 1.66±0.30 vs. 1.59±0.26; p=0.01) but transmitral gradient (mean gradient; 6.49±2.51 vs. 8.89±3.52; p=0.001, maximal gradient: 16.94±5.11 vs. 18.57±4.54; p=0.01) and Cn values (5.37±0.77 vs. 6.26±0.64; p<0.001) were higher in the AF than SR. There was a significant correlation between Cn difference and transmitral gradient difference (mean and maximal) (Cn difference-mean gradient difference; r=0.46; p=0.05; Cn difference-maximal gradient difference; r=0.72; p=0.001). Cardiac rhythm has a significant impact on echocardiographic evaluation of MVA, transmitral gradient, and Cn in patients with MS.
Long Range In-Plane Order of Oriented Diblock Copolymer Thin Films by Graphoepitaxy
NASA Astrophysics Data System (ADS)
Fontana, Scott; Dadmun, Mark; Lowndes, Douglas
2003-03-01
Previous work by Russell and coworkers has demonstrated that controlling the interfacial energies and wetting behavior of an asymmetric diblock copolymer enables the control of the orientation of its microphases. In particular the cylindrical phase can be readily aligned perpendicular to a substrate when it is placed on a surface that is neutral to both components of the copolymer. The minor phase, PMMA may then be removed using UV radiation leaving a nanoporous template. In this work, we will report long range, in-plane ordering of the hexagonally packed nanopores that is achieved using graphoepitaxy. The long range ordered and vertically aligned diblock copolymer film can be used to produce arrays of catalytic nickel dots, which grow vertically aligned carbon nano-fibers (VACNF), resulting in a well ordered array of VACNFs.
Molecular dynamics simulations of proton-ordered water confined in low-diameter carbon nanotubes.
Li, Shujuan; Schmidt, Burkhard
2015-03-21
The present work deals with molecular dynamics simulations of water confined in single-walled carbon nanotubes (CNTs), with emphasis on the proton-ordering of water and its polarization. First, the water occupancy of open-ended armchair and zigzag CNTs immersed in water under ambient NPT conditions is calculated for various water models, and for varying Lennard-Jones parameters of the water-carbon interaction. As a function of the CNT diameter, the water density displays several oscillations before converging to the bulk value. Based on these results, the water structures encapsulated in 10 nm long armchair CNTs (n,n) with 5 ≤ n ≤ 10, are investigated under NVT conditions. Inside the smallest nanotubes (n = 5, 6) highly ferroelectric (FE), quasi-one-dimensional water chains are found while inside the other CNTs water molecules assemble into single-walled ice nanotubes (INTs). There are several, near-degenerate minimum energy INT structures: single helical structures were found for 7 ≤ n ≤ 10, in all cases in FE arrangement. In addition, a double helical INT structure was found for n = 8 with an even higher polarization. Prism-like structures were found only for 8 ≤ n ≤ 10 with various FE, ferrielectric (FI), and antiferroelectric (AF, n = 9, 10) proton ordering. The coexistence of the nearly iso-energetic FE, FI, and AF INT structures separated by high barriers renders the molecular dynamics highly metastable, typically with nanosecond timescales at room temperature. Hence, the replica exchange simulation method is used to obtain populations of different INT states at finite temperatures. Many of the FE INT structures confined in low-diameter CNTs are still prevalent at room temperature. Both helix-helix and helix-prism structural transitions are detected which can be either continuous (around 470 K for n = 8) or discontinuous (at 218 K for n = 9). Also melting-like transitions are found in which the INT structures are disrupted leading to a loss of FE or FI ordering of the water orientations. Also these transitions can be either smooth (for n = 7, 8) or abrupt, first-order transitions, at T = 362 K for n = 9 and at T = 285 K for n = 10.
RUSSO, VINCENZO; NIGRO, GERARDO; RAGO, ANNA; ANTONIO PAPA, ANDREA; PROIETTI, RICCARDO; DELLA CIOPPA, NADIA; CRISTIANO, ANNA; PALLADINO, ALBERTO; CALABRÒ, RAFFAELE; POLITANO, LUISA
2013-01-01
The role that atrial pacing therapy plays on the atrial fibrillation (AF) burden is still unclear. Aim of the study was to evaluate the effect of the atrial preference pacing algorithm on AF burden in patients affected by Myotonic Dystrophy type 1 (DM1) followed for a long follow up period. Sixty DM1 patients were -implanted with a dual chamber pacemaker (PM) for first degree or symptomatic type 1/type 2 second degree atrio-ventricular blocks- were followed for 2-years after implantation, by periodical examination. After 1 month of stabilization, they were randomized into two groups: 1) Patients implanted with conventional dual-chamber pacing mode (DDDR group) and 2) Patients implanted with DDDR plus Atrial Preference Pacing (APP) algorithm (APP ON group). The results showed that atrial tachycardia (AT)/AF burden was significantly reduced at 1 year follow up in the APP ON group (2122 ± 428 minutes vs 4127 ± 388 minutes, P = 0.03), with a further reduction at the end of the 2 year follow up period (4652 ± 348 minutes vs 7564 ± 638 minutes, P = 0.005). The data here reported show that the APP is an efficient algorithm to reduce AT/AF burden in DM1 patients implanted with dual chamber pacemaker. PMID:24803841
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xiao-Qing; Zhang, Dao-Liang; Zhang, Ming-Jian
Aims: Atrial fibroblasts and macrophages have long been thought to participate in atrial fibrillation (AF). However, which specific mediator may regulate the interaction between them remains unclear. Methods and results: We provided the evidence for the involvement of Toll/IL-1 receptor domain-containing adaptor inducing IFN-β (TRIF), an important inflammation-related molecule, in the pathophysiology of AF. Patients with AF showed higher levels of angiotensin II (AngII) and TRIF expression and larger number of macrophages infiltration in left atria appendage than individuals with sinus rhythm (SR). In the cell study, AngII induced chemokines expressions in mouse atrial fibroblasts and AngII-stimulated atrial fibroblasts inducedmore » the chemotaxis of macrophages, which were reduced by losartan and TRIF siRNA. Meanwhile, AngII-stimulated atrial fibroblasts proliferation was enhanced by macrophages. Conclusions: Our data demonstrated that TRIF may be a crucial factor promoting the interaction between atrial fibroblasts and macrophages, leading to atrial fibrosis. - Highlights: • Compared with SR, AF showed higher TRIF expression in left atrial appendage. • TRIF siRNA reversed macrophage chemotaxis induced by AngII-treated fibroblast. • TRIF siRNA reversed chemokines expressions induced by AngII in fibroblast. • AngII-stimulated atrial fibroblast proliferation was enhanced by macrophage.« less
Long-Range Order in Nanocrystal Assemblies Determines Charge Transport of Films
Sainato, Michela; Shevitski, Brian; Sahu, Ayaskanta; ...
2017-07-18
Self-assembly of semiconductor nanocrystals (NCs) into two-dimensional patterns or three-dimensional (2- 3D) superstructures has emerged as a promising low-cost route to generate thin-film transistors and solar cells with superior charge transport because of enhanced electronic coupling between the NCs. Here, we show that lead sulfide (PbS) NCs solids featuring either short-range (disordered glassy solids, GSs) or long-range (superlattices, SLs) packing order are obtained solely by controlling deposition conditions of colloidal solution of NCs. In this study, we demonstrate the use of the evaporation-driven self-assembly method results in PbS NC SL structures that are observed over an area of 1 mmmore » × 100 μm, with long-range translational order of up to 100 nm. A number of ordered domains appear to have nucleated simultaneously and grown together over the whole area, imparting a polycrystalline texture to the 3D SL films. By contrast, a conventional, optimized spin-coating deposition method results in PbS NC glassy films with no translational symmetry and much shorter-range packing order in agreement with state-of-the-art reports. Further, we investigate the electronic properties of both SL and GS films, using a field-effect transistor configuration as a test platform. The long-range ordering of the PbS NCs into SLs leads to semiconducting NC-based solids, the mobility (μ) of which is 3 orders of magnitude higher than that of the disordered GSs. Furthemore, although spin-cast GSs of PbS NCs have weak ambipolar behavior with limited gate tunability, SLs of PbS NCs show a clear p-type behavior with significantly higher conductivities.« less
NASA Astrophysics Data System (ADS)
Huynh, K. K.; Tanabe, Y.; Urata, T.; Oguro, H.; Heguri, S.; Watanabe, K.; Tanigaki, K.
2014-10-01
An SDW antiferromagnetic (SDW-AF) low-temperature phase transition is generally observed and the AF spin fluctuations are considered to play an important role for the superconductivity pairing mechanism in FeAs superconductors. However, a similar magnetic phase transition is not observed in FeSe superconductors, which has caused considerable discussion. We report on the intrinsic electronic states of FeSe as elucidated by electric transport measurements under magnetic fields using a high quality single crystal. A mobility spectrum analysis, an ab initio method that does not make assumptions on the transport parameters in a multicarrier system, provides very important and clear evidence that another hidden order, most likely the symmetry broken from the tetragonal C4 symmetry to the C2 symmetry nematicity associated with the selective d -orbital splitting, exists in the case of superconducting FeSe other than the AF magnetic order spin fluctuations. The intrinsic low-temperature phase in FeSe is in the almost compensated semimetallic states but is additionally accompanied by Dirac cone-like ultrafast electrons ˜104cm2(VS) -1 as minority carriers.
Bousis, Christos; Emfietzoglou, Dimitris; Nikjoo, Hooshang
2012-12-01
To calculate the absorbed fraction (AF) of low energy electrons in small tissue-equivalent spherical volumes by Monte Carlo (MC) track structure simulation and assess the influence of phase (liquid water versus density-scaled water vapor) and of the continuous-slowing-down approximation (CSDA) used in semi-analytic calculations. An event-by-event MC code simulating the transport of electrons in both the vapor and liquid phase of water using appropriate electron-water interaction cross sections was used to quantify the energy deposition of low-energy electrons in spherical volumes. Semi-analytic calculations within the CSDA using a convolution integral of the Howell range-energy expressions are also presented for comparison. The AF for spherical volumes of radii from 10-1000 nm are presented for monoenergetic electrons over the energy range 100-10,000 eV and the two Auger-emitting radionuclides (125)I and (123)I. The MC calculated AF for the liquid phase are found to be smaller than those of the (density scaled) gas phase by up to 10-20% for the monoenergetic electrons and 10% for the two Auger-emitters. Differences between the liquid-phase MC results and the semi-analytic CSDA calculations are up to ∼ 55% for the monoenergetic electrons and up to ∼ 35% for the two Auger-emitters. Condensed-phase effects in the inelastic interaction of low-energy electrons with water have a noticeable but relatively small impact on the AF for the energy range and target sizes examined. Depending on the electron energies, the semi-analytic approach may lead to sizeable errors for target sizes with linear dimensions below 1 micron.
Characterization of a water-solid interaction in a partially ordered system.
Chakravarty, Paroma; Lubach, Joseph W
2013-11-04
GNE068-PC, a developmental compound, was previously characterized to be mesomorphous, i.e. having long-range order associated with significant local molecular disorder (Chakravarty et. al., Mol. Pharmaceutics, accepted). The compound was exposed to moisture under different relative humidity conditions ranging from 11% to 60% RH at room temperature (RT) for 7 days, and the resultant product phases were characterized. The partially ordered sample progressively lost crystallinity (long-range order) and birefringence (orientational order) upon exposure to increasing RH conditions, leading to the formation of a completely disordered amorphous phase at 60% RH (RT). Long-range positional order was irrecoverable even after moisture removal from the sample exposed to 60% RH. This was attributed to replacement of residual ethyl acetate by water, the former being critical for maintenance of long-range order in the material. In addition, water sorption appeared to irreversibly alter the molecular orientation, thereby affecting sample birefringence. Solid-state NMR revealed increases in (1)H and (13)C spin-lattice relaxation times (T1) going from the mesomorphous phase to the fully amorphous phase. This was indicative of reduction in lattice mobility, likely due to the decreased motion of the aromatic portions of the molecule, in particular C17, which showed the most dramatic increase in (13)C T1. This is likely due to decrease in available free volume upon water sorption. Drying of the hydrated disordered phase showed somewhat greater mobility than the hydrated phase, likely due to increased relative free volume through removal of water. A water-solid interaction therefore irreversibly changed the solid-state makeup of GNE068-PC.
Zarzoso, Vicente; Latcu, Decebal G; Hidalgo-Muñoz, Antonio R; Meo, Marianna; Meste, Olivier; Popescu, Irina; Saoudi, Nadir
2016-12-01
Catheter ablation (CA) of persistent atrial fibrillation (AF) is challenging, and reported results are capable of improvement. A better patient selection for the procedure could enhance its success rate while avoiding the risks associated with ablation, especially for patients with low odds of favorable outcome. CA outcome can be predicted non-invasively by atrial fibrillatory wave (f-wave) amplitude, but previous works focused mostly on manual measures in single electrocardiogram (ECG) leads only. To assess the long-term prediction ability of f-wave amplitude when computed in multiple ECG leads. Sixty-two patients with persistent AF (52 men; mean age 61.5±10.4years) referred for CA were enrolled. A standard 1-minute 12-lead ECG was acquired before the ablation procedure for each patient. F-wave amplitudes in different ECG leads were computed by a non-invasive signal processing algorithm, and combined into a mutivariate prediction model based on logistic regression. During an average follow-up of 13.9±8.3months, 47 patients had no AF recurrence after ablation. A lead selection approach relying on the Wald index pointed to I, V1, V2 and V5 as the most relevant ECG leads to predict jointly CA outcome using f-wave amplitudes, reaching an area under the curve of 0.854, and improving on single-lead amplitude-based predictors. Analysing the f-wave amplitude in several ECG leads simultaneously can significantly improve CA long-term outcome prediction in persistent AF compared with predictors based on single-lead measures. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Ozcan, Cevher; Jahangir, Arshad; Friedman, Paul A; Munger, Thomas M; Packer, Douglas L; Hodge, David O; Hayes, David L; Gersh, Bernard J; Hammill, Stephen C; Shen, Win-Kuang
2003-07-01
Control of ventricular rate by atrioventricular node ablation and pacemaker implantation in patients with drug-refractory atrial fibrillation (AF) is associated with improved left ventricular (LV) function. The objective of this study was to determine the effect of atrioventricular node ablation on long-term survival in patients with AF and LV dysfunction. Survival was determined by the Kaplan-Meier method for 56 study patients with LV ejection fraction (EF) < or =40% who underwent atrioventricular node ablation and pacemaker implantation and 56 age- and gender-matched control patients with AF and LVEF >40%, and age- and gender-matched control subjects from Minnesota. Groups were compared using the log-rank test. In study patients (age 69 +/- 10 years; 45 men), LVEF was 26% +/- 8% and 34% +/- 13% (p <0.001) before and after ablation, respectively. During follow-up (40 +/- 23 months), 23 patients died. Observed survival was worse than that of normal subjects (p <0.001) and control patients (p = 0.005). After ablation, LVEF nearly normalized (> or =45%) in 16 study patients (29%), in whom observed survival was comparable to that of normal subjects (p = 0.37). Coronary artery disease, hyperlipidemia, chronic renal failure, previous myocardial infarction, and coronary artery operation were independent predictors for mortality. Near normalization of LVEF occurred in 29% of study patients, suggesting that AF-induced EF reduction is reversible in many patients. Normal survival in patients with reversible LV dysfunction highlights potential survival benefits of rate control. Poor survival in patients with persistent LV dysfunction confirms the importance of optimal medical therapy.
Air Force Research Laboratory’s Focused Long Term Challenges
2008-04-01
Air Force Research Laboratory ( AFRL ) mission is to provide support to the Air Force (AF) and the warfighters with... Air Force Research Laboratory’s Focused Long Term Challenges Leo J Rose Munitions Directorate, Air Force Research Laboratory , 101 W Eglin Blvd...This technology vision, which was born in our Air Force Research Laboratory , builds on the Air Force’s traditional kill
Genevieve, M; Vivot, A; Gonzalez, C; Raffaitin, C; Barberger-Gateau, P; Gin, H; Rigalleau, V
2013-09-01
As skin autofluorescence (AF) can assess subcutaneous accumulation of fluorescent advanced glycation end-products (AGEs), this study aimed to investigate whether it was linked to glycaemic control and complications in patients with type 1 diabetes mellitus (T1DM). Using the AGE Reader™, AF was measured in T1DM patients referred to Haut-Levêque Hospital (Bordeaux, France); data on their HbA1c levels measured every 6months as far back as the last 5years were also collected. The association of AF with the patients' past glucose control, based on their latest HbA1c values, and the means of the last five and 10 HbA1c values, and with diabetic complications was also examined by linear regression analysis. The sample included 300 patients: 58% were male; the mean age was 49 (SD 17) years and the mean diabetes duration was 21 (SD 13) years. The median skin AF measurement was 2.0 [25th-75th percentiles: 1.7-2.4] arbitrary units (AU), and this was associated with age (β=0.15 per 10years, P<0.001) and diabetes duration (β=0.17 per 10years, P<0.001). After adjusting for age and estimated glomerular filtration rate (eGFR), the skin AF measurement was also related to the means of the last five and 10 HbA1c values (β=0.10 per 1% of HbA1c, P=0.005, and β=0.13 per 1% of HbA1c, P=0.001, respectively). In addition, the skin AF was associated with retinopathy (P<0.001), albuminuria (P<0.001) and decreased eGFR (P<0.001). In conclusion, the skin AF is related to the long-term glucose control and diabetic complications. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Uhm, Jae-Sun; Won, Hoyoun; Joung, Boyoung; Nam, Gi-Byoung; Choi, Kee-Joon; Lee, Moon-Hyoung; Kim, You-Ho
2014-01-01
Purpose Although current guidelines recommend continuing the same antithrombotic strategy regardless of rhythm control after radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF), anticoagulation has a risk of major bleeding. We evaluated the safety of switching warfarin to aspirin in patients with successful AF ablation. Materials and Methods Among 721 patients who underwent RFCA of AF, 608 patients (age, 57.3±10.9 years; 77.0% male, 75.5% paroxysmal AF) who had no evidence of AF recurrence at 3 months post-RFCA were included. We compared the thromboembolic and hemorrhagic events in patients for whom warfarin was switched to aspirin (ASA group; n=296) and patients who were kept on warfarin therapy (W group; n=312). Results There were no significant differences in CHA2DS2-VASc or HAS-BLED scores between the groups. In 30 patients in the ASA group and 37 patients in W group, AF recurred and warfarin was restarted or maintained during the 18.0±12.2 months of follow-up. There were no significant differences in thromboembolic (0.3% vs. 1.0%, p=0.342) and major bleeding incidences (0.7% vs. 0.6%, p=0.958) between ASA and W groups during the follow-up period. In the 259 patients with a CHA2DS2-VASc score ≥2, there were no significant differences in thromboembolism (0.8% and 2.2%, p=0.380) or major bleeding incidences (0.8% and 1.4%, p=0.640) between ASA and W groups. Conclusion Switching warfarin to aspirin 3 months after successful RFCA of AF could be as safe and efficacious as long-term anticoagulation even in patients with CHA2DS2-VASc score ≥2. However, strict rhythm monitoring cannot be overemphasized. PMID:25048480
Kirchhof, Paulus; Ammentorp, Bettina; Darius, Harald; De Caterina, Raffaele; Le Heuzey, Jean-Yves; Schilling, Richard John; Schmitt, Josef; Zamorano, Jose Luis
2014-01-01
We sought to describe the management of patients with atrial fibrillation (AF) in Europe after the release of the 2010 AF Guidelines of the European Society of Cardiology. The PREFER in AF registry enrolled consecutive patients with AF from January 2012 to January 2013 in 461 centres in seven European countries. Seven thousand two hundred and forty-three evaluable patients were enrolled, aged 71.5 ± 11 years, 60.1% male, CHA2DS2VASc score 3.4 ± 1.8 (mean ± standard deviation). Thirty per cent patients had paroxysmal, 24.0% had persistent, 7.2% had long-standing persistent, and 38.8% had permanent AF. Oral anticoagulation was used in the majority of patients: 4799 patients (66.3%) received a vitamin K antagonist (VKA) as mono-therapy, 720 patients a combination of VKA and antiplatelet agents (9.9%), 442 patients (6.1%) a new oral anticoagulant drugs (NOAC). Antiplatelet agents alone were given to 808 patients (11.2%), no antithrombotic therapy to 474 patients (6.5%). Of 7034 evaluable patients, 5530 (78.6%) patients were adequately rate controlled (mean heart rate 60-100 bpm). Half of the patients (50.7%) received rhythm control therapy by electrical cardioversion (18.1%), pharmacological cardioversion (19.5%), antiarrhythmic drugs (amiodarone 24.1%, flecainide or propafenone 13.5%, sotalol 5.5%, dronedarone 4.0%), and catheter ablation (5.0%). The management of AF patients in 2012 has adapted to recent evidence and guideline recommendations. Oral anticoagulant therapy with VKA (majority) or NOACs is given to over 80% of eligible patients, including those at risk for bleeding. Rate is often adequately controlled, and rhythm control therapy is widely used.
Portnoy, Sigal; Halaby, Orli; Dekel-Chen, Dotan; Dierick, Frédéric
2015-11-01
Pouring hot water from a kettle into a cup may prove a hazardous task, especially for the elderly or the visually-impaired. Individuals with deteriorating eyesight may endanger their hands by performing this task with both hands, relaying on tactilo-kinesthetic feedback (TKF). Auditory feedback (AF) may allow them to perform the task singlehandedly, thereby reducing the risk for injury. However since relying on an AF is not intuitive and requires practice, we aimed to determine if AF supplied during the task of pouring water can be used naturally as visual feedback (VF) following practice. For this purpose, we quantified, in young healthy sighted subjects (n = 20), the performance and kinematics of pouring water in the presence of three isolated feedbacks: visual, tactilo-kinesthetic, or auditory. There were no significant differences between the weights of spilled water in the AF condition compared to the TKF condition in the first, fifth or thirteenth trials. The subjectively-reported difficulty levels of using the TKF and the AF were significantly reduced between the first and thirteenth trials for both TKF (p = 0.01) and AF (p = 0.001). Trunk rotation during the first trial using the TKF was significantly lower than the trunk rotation while using VF. Also, shoulder adduction during the first trial using the TKF was significantly higher than the shoulder adduction while using the VF. During the AF trials, the median travel distance of the tip of the kettle was significantly reduced in the first trials so that in the thirtieth trial it did not differ significantly from the median travel distance during the thirtieth trial using TKF and VF. The maximal velocity of the tip of the kettle was constant for each of the feedback conditions but was higher in 10 cm s(-1) using VF than TKF, which was higher in 10 cm s(-1) from using AF. The smoothness of movement of the TKF and AF conditions, expressed by the normalized jerk score (NJSM), was one and two orders of magnitude higher from the VF, respectively. The median NJSM then decreased significantly by the fifth trial. Monitoring in-house activity via motion capture and classification of movements, i.e. liquid pouring, can assist with daily activities via AF. As a built-in feature in a smart home, this task-specific AF may prevent burn injuries of the visually-impaired. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Winkle, Roger A; Moskovitz, Ryan; Hardwin Mead, R; Engel, Gregory; Kong, Melissa H; Fleming, William; Salcedo, Jonathan; Patrawala, Rob A; Tranter, John H; Shai, Isaac
2018-06-01
The optimal radiofrequency (RF) power and lesion duration using contact force (CF) sensing catheters for atrial fibrillation (AF) ablation are unknown. We evaluate 50 W RF power for very short durations using CF sensing catheters during AF ablation. We evaluated 51 patients with paroxysmal (n = 20) or persistent (n = 31) AF undergoing initial RF ablation. A total of 3961 50 W RF lesions were given (average 77.6 ± 19.1/patient) for an average duration of only 11.2 ± 3.7 s. As CF increased from < 10 to > 40 g, the RF application duration decreased from 13.7 ± 4.4 to 8.6 ± 2.5 s (p < 0.0005). Impedance drops occurred in all ablations, and for patients in sinus rhythm, there was loss of pacing capture during RF delivery suggesting lesion creation. Only 3% of the ablation lesions were at < 5 g and 1% at > 40 g of force. As CF increased, the force time integral (FTI) increased from 47 ± 24 to 376 ± 102 gs (p < 0.0005) and the lesion index (LSI) increased from 4.10 ± 0.51 to 7.63 ± 0.50 (p < 0.0005). Both procedure time (101 ± 19.7 min) and total RF energy time (895 ± 258 s) were very short. For paroxysmal AF, the single procedure freedom from AF was 86% at 1 and 2 years. For persistent AF, it was 83% at 1 year and 72% at 2 years. There were no complications. Short duration 50 W ablations using CF sensing catheters are safe and result in excellent long-term freedom from AF for both paroxysmal and persistent AF with short procedure times and small amounts of total RF energy delivery.
Eckstein, Jens; Potocki, Mihael; Murray, Karsten; Breidthardt, Tobias; Ziller, Ronny; Mosimann, Tamina; Klima, Theresia; Hoeller, Rebeca; Moehring, Berit; Sou, Seoung Mann; Rubini Gimenez, Maria; Morgenthaler, Nils G; Mueller, Christian
2012-10-01
Due to different release mechanisms, mid-regional pro-atrial natriuretic peptide (MR proANP) may be superior to N-terminal pro-B-type natriuretic peptide (NT proBNP) in the diagnosis of acute heart failure (AHF) in patients with atrial fibrillation (AF). We compared MR proANP and NT proBNP for their diagnostic value in patients with AF and sinus rhythm (SR). Prospective cohort study. University hospital, emergency department. 632 consecutive patients presenting with acute dyspnoea. MR proANP and NT proBNP plasma levels were determined. The diagnosis of AHF was adjudicated by two independent cardiologists using all available data. Patients received long-term follow-up. AF was present in 151 patients (24%). MR proANP and NT proBNP levels were significantly higher in the AF group compared with the SR group (385 (258-598) versus 201 (89-375) pmol/l for MR proANP, p<0.001 and 4916 (2169-10285) versus 1177 (258-5166) pg/ml, p<0.001 for NT proBNP). Diagnostic accuracy in AF patients was similar for MR proANP (0.90, 95% CI 0.84 to 0.95) and NT proBNP (0.89, 95% CI 0.81 to 0.96). Optimal cut-off levels in AF patients were significantly higher compared with the optimal cut-off levels for patients in SR (MR proANP 240 vs 200 pmol/l; NT proBNP 2670 vs 1500 pg/ml respectively). After adjustment in multivariable Cox proportional hazard analysis, MR proANP strongly predicted one-year all-cause mortality (HR=1.13 (1.09-1.17), per 100 pmol/l increase, p<0.001). In AF patients, NT proBNP and MR proANP have similar diagnostic value for the diagnosis of AHF. The rhythm at presentation has to be taken into account because plasma levels of both peptides are significantly higher in patients with AF compared with SR.
Vukajlovic, Dejan; Gussak, Ihor; George, Samuel; Simic, Goran; Bojovic, Bosko; Hadzievski, Ljupco; Stojanovic, Bojan; Angelkov, Lazar; Panescu, Dorin
2011-01-01
Differential diagnosis of symptomatic events in post-ablation atrial fibrillation (AF) patients (pts) is important; in particular, accurate, reliable detection of AF or atrial flutter (AFL) is essential. However, existing remote monitoring devices usually require attached leads and are not suitable for prolonged monitoring; moreover, most do not provide sufficient information to assess atrial activity, since they generally monitor only 1-3 ECG leads and rely on RR interval variability for AF diagnosis. A new hand-held, wireless, symptom-activated event monitor (CardioBip; CB) does not require attached leads and hence can be conveniently used for extended periods. Moreover, CB provides data that enables remote reconstruction of full 12-lead ECG data including atrial signal information. We hypothesized that these CB features would enable accurate remote differential diagnosis of symptomatic arrhythmias in post-ablation AF pts. 21 pts who underwent catheter ablation for AF were instructed to make a CB transmission (TX) whenever palpitations, lightheadedness, or similar symptoms occurred, and at multiple times daily when asymptomatic, during a 60 day post-ablation time period. CB transmissions (TXs) were analyzed blindly by 2 expert readers, with differences adjudicated by consensus. 7 pts had no symptomatic episodes during the monitoring period. 14 of 21 pts had symptomatic events and made a total of 1699 TX, 164 of which were during symptoms. TX quality was acceptable for rhythm diagnosis and atrial activity in 96%. 118 TX from 10 symptomatic pts showed AF (96 TX from 10 pts) or AFL (22 TX from 3 pts), and 46 TX from 9 pts showed frequent PACs or PVCs. No other arrhythmias were detected. Five pts made symptomatic TX during AF/AFL and also during PACs/PVCs. Use of CB during symptomatic episodes enabled detection and differential diagnosis of symptomatic arrhythmias. The ability of CB to provide accurate reconstruction of 12 L ECGs including atrial activity, combined with its ease of use, makes it suitable for long-term surveillance for recurrent AF in post-ablation patients.
Survey on Urinary Levels of Aflatoxins in Professionally Exposed Workers
Ferri, Fulvio; Brera, Carlo; De Santis, Barbara; Fedrizzi, Giorgio; Bacci, Tiziana; Bedogni, Lorena; Capanni, Sauro; Collini, Giorgia; Crespi, Enrica; Debegnach, Francesca; Ferdenzi, Patrizia; Gargano, Angelo; Gattei, Daniela; Luberto, Ferdinando; Magnani, Ines; Magnani, Massimo Giuseppe; Mancuso, Pamela; Menotta, Simonetta; Mozzanica, Stefania; Olmi, Milva; Ombrini, Giuseppe; Sala, Orietta; Soricelli, Sabina; Vicentini, Massimo; Giorgi Rossi, Paolo
2017-01-01
Feed mill workers may handle or process maize contaminated with aflatoxins (AFs). This condition may lead to an unacceptable intake of toxins deriving from occupational exposure. This study assessed the serological and urinary levels of AFs in workers exposed to potentially contaminated dusts in two mills. From March to April 2014, blood and urine samples were collected, on Monday and Friday morning of the same working week from 29 exposed workers and 30 non-exposed controls. AFs (M1, G2, G1, B1, B2) and aflatoxicol (AFOH) A were analyzed. Each subject filled in a questionnaire to evaluate potential food-borne exposures to mycotoxins. AFs contamination in environmental dust was measured in both plants. No serum sample was found to be positive. Seventy four percent of urine samples (73.7%) revealed AFM1 presence. AFM1 mean concentration was 0.035 and 0.027 ng/mL in exposed and non-exposed workers, respectively (p = 0.432); the concentration was slightly higher in Friday’s than in Monday’s samples, in exposed workers, 0.040 versus (vs.) 0.031 and non-exposed controls (0.030 vs. 0.024, p = 0.437). Environmental AFs contamination ranged from 7.2 to 125.4 µg/kg. The findings of this study reveal the presence of higher AFs concentration in exposed workers than in non-exposed controls, although these differences are to be considered consistent with random fluctuations. PMID:28338636