Reliability and Engineering | Photovoltaic Research | NREL
-Time PV and Solar Resource Testing We study long-term performance, reliability, and failures of PV (NCPV) at NREL, we focus on photovoltaic (PV) reliability research and development (R&D) to improve PV technologies. We test modules and systems for long-term performance and stress them in the field
Failure Analysis Study and Long-Term Reliability of Optical Assemblies with End-Face Damage
NASA Technical Reports Server (NTRS)
Kichak, Robert A.; Ott, Melanie N.; Leidecker, Henning W.; Chuska, Richard F.; Greenwell, Christopher J.
2008-01-01
In June 2005, the NESC received a multi-faceted request to determine the long term reliability of fiber optic termini on the ISS that exhibited flaws not manufactured to best workmanship practices. There was a lack of data related to fiber optic workmanship as it affects the long term reliability of optical fiber assemblies in a harsh environment. A fiber optic defect analysis was requested which would find and/or create various types of chips, spalls, scratches, etc., that were identified by the ISS personnel. Once the defects and causes were identified the next step would be to perform long term reliability testing of similar assemblies with similar defects. The goal of the defect analysis would be for the defects to be observed and documented for deterioration of fiber optic performance. Though this report mostly discusses what has been determined as evidence of poor manufacturing processes, it also concludes the majority of the damage could have been avoided with a rigorous process in place.
NASA Astrophysics Data System (ADS)
Taylor, John R.; Stolz, Christopher J.
1993-08-01
Laser system performance and reliability depends on the related performance and reliability of the optical components which define the cavity and transport subsystems. High-average-power and long transport lengths impose specific requirements on component performance. The complexity of the manufacturing process for optical components requires a high degree of process control and verification. Qualification has proven effective in ensuring confidence in the procurement process for these optical components. Issues related to component reliability have been studied and provide useful information to better understand the long term performance and reliability of the laser system.
NASA Astrophysics Data System (ADS)
Taylor, J. R.; Stolz, C. J.
1992-12-01
Laser system performance and reliability depends on the related performance and reliability of the optical components which define the cavity and transport subsystems. High-average-power and long transport lengths impose specific requirements on component performance. The complexity of the manufacturing process for optical components requires a high degree of process control and verification. Qualification has proven effective in ensuring confidence in the procurement process for these optical components. Issues related to component reliability have been studied and provide useful information to better understand the long term performance and reliability of the laser system.
Reliability of Long-Term Wave Conditions Predicted with Data Sets of Short Duration
1985-03-01
the validity and reliability of predicted probable wave heights obtained from data of limited duration. BACKGROUND: The basic steps listed by...interest to perform the analysis outlined in steps 2 to 5, the prediction would only be reliable for up to a 3year return period. For a 5-year data set...for long-term hindcast data . The data retrieval and analysis program known as the Sea State Engineering Analysis System (SEAS) makes handling of the
Reliability Issues in Stirling Radioisotope Power Systems
NASA Technical Reports Server (NTRS)
Schreiber, Jeffrey; Shah, Ashwin
2005-01-01
Stirling power conversion is a potential candidate for use in a Radioisotope Power System (RPS) for space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power and reduced requirement of radioactive material. Reliability of an RPS that utilizes Stirling power conversion technology is important in order to ascertain long term successful performance. Owing to long life time requirement (14 years), it is difficult to perform long-term tests that encompass all the uncertainties involved in the design variables of components and subsystems comprising the RPS. The requirement for uninterrupted performance reliability and related issues are discussed, and some of the critical areas of concern are identified. An overview of the current on-going efforts to understand component life, design variables at the component and system levels, and related sources and nature of uncertainties are also discussed. Current status of the 110 watt Stirling Radioisotope Generator (SRG110) reliability efforts is described. Additionally, an approach showing the use of past experience on other successfully used power systems to develop a reliability plan for the SRG110 design is outlined.
Reliability Issues in Stirling Radioisotope Power Systems
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Schreiber, Jeffrey G.
2004-01-01
Stirling power conversion is a potential candidate for use in a Radioisotope Power System (RPS) for space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power and reduced requirement of radioactive material. Reliability of an RPS that utilizes Stirling power conversion technology is important in order to ascertain long term successful performance. Owing to long life time requirement (14 years), it is difficult to perform long-term tests that encompass all the uncertainties involved in the design variables of components and subsystems comprising the RPS. The requirement for uninterrupted performance reliability and related issues are discussed, and some of the critical areas of concern are identified. An overview of the current on-going efforts to understand component life, design variables at the component and system levels, and related sources and nature of uncertainties are also discussed. Current status of the 110 watt Stirling Radioisotope Generator (SRG110) reliability efforts is described. Additionally, an approach showing the use of past experience on other successfully used power systems to develop a reliability plan for the SRG110 design is outlined.
NASA Technical Reports Server (NTRS)
Kern, E.
1982-01-01
Research on residential photovoltaic power systems based upon the experience of MIT-LL in implementing the DOE Residential Demonstration Project, especially the Northeast Residential Experiment Station (NE RES) is discussed. There is an immediate need for improved power-conditioner operational and reliability capabilities. Continuing evaluation of photovoltaic power systems is required to verify long-term performance, reliability, and utility interface effects. In the long term, the price of photovoltaic power systems must decrease, especially of modules.
Structural composite panel performance under long-term load
Theodore L. Laufenberg
1988-01-01
Information on the performance of wood-based structural composite panels under long-term load is currently needed to permit their use in engineered assemblies and systems. A broad assessment of the time-dependent properties of panels is critical for creating databases and models of the creep-rupture phenomenon that lead to reliability-based design procedures. This...
Vianco, Paul T.
2017-03-01
Whether structural or electronic, all solder joints must provide the necessary level of reliability for the application. The Part 1 report examined the effects of filler metal properties and the soldering process on joint reliability. Filler metal solderability and mechanical properties, as well as the extents of base material dissolution and interface reaction that occur during the soldering process, were shown to affect reliability performance. The continuation of this discussion is presented in this Part 2 report, which highlights those factors that directly affect solder joint reliability. There is the growth of an intermetallic compound (IMC) reaction layer at themore » solder/base material interface by means of solid-state diffusion processes. In terms of mechanical response by the solder joint, fatigue remains as the foremost concern for long-term performance. Thermal mechanical fatigue (TMF), a form of low-cycle fatigue (LCF), occurs when temperature cycling is combined with mismatched values of the coefficient of thermal expansion (CTE) between materials comprising the solder joint “system.” Vibration environments give rise to high-cycle fatigue (HCF) degradation. Although accelerated aging studies provide valuable empirical data, too many variants of filler metals, base materials, joint geometries, and service environments are forcing design engineers to embrace computational modeling to predict the long-term reliability of solder joints.« less
Benchmark analysis of forecasted seasonal temperature over different climatic areas
NASA Astrophysics Data System (ADS)
Giunta, G.; Salerno, R.; Ceppi, A.; Ercolani, G.; Mancini, M.
2015-12-01
From a long-term perspective, an improvement of seasonal forecasting, which is often exclusively based on climatology, could provide a new capability for the management of energy resources in a time scale of just a few months. This paper regards a benchmark analysis in relation to long-term temperature forecasts over Italy in the year 2010, comparing the eni-kassandra meteo forecast (e-kmf®) model, the Climate Forecast System-National Centers for Environmental Prediction (CFS-NCEP) model, and the climatological reference (based on 25-year data) with observations. Statistical indexes are used to understand the reliability of the prediction of 2-m monthly air temperatures with a perspective of 12 weeks ahead. The results show how the best performance is achieved by the e-kmf® system which improves the reliability for long-term forecasts compared to climatology and the CFS-NCEP model. By using the reliable high-performance forecast system, it is possible to optimize the natural gas portfolio and management operations, thereby obtaining a competitive advantage in the European energy market.
Accelerated testing of module-level power electronics for long-term reliability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flicker, Jack David; Tamizhmani, Govindasamy; Moorthy, Mathan Kumar
This work has applied a suite of long-term-reliability accelerated tests to a variety of module-level power electronics (MLPE) devices (such as microinverters and optimizers) from five different manufacturers. This dataset is one of the first (only the paper by Parker et al. entitled “Dominant factors affecting reliability of alternating current photovoltaic modules,” in Proc. 42nd IEEE Photovoltaic Spec. Conf., 2015, is reported for reliability testing in the literature), as well as the largest, experimental sets in public literature, both in the sample size (five manufacturers including both dc/dc and dc/ac units and 20 units for each test) and the numbermore » of experiments (six different experimental test conditions) for MLPE devices. The accelerated stress tests (thermal cycling test per IEC 61215 profile, damp heat test per IEC 61215 profile, and static temperature tests at 100 and 125 °C) were performed under powered and unpowered conditions. The first independent long-term experimental data regarding damp heat and grid transient testing, as well as the longest term (>9 month) testing of MLPE units reported in the literature for thermal cycling and high-temperature operating life, are included in these experiments. Additionally, this work is the first to show in situ power measurements, as well as periodic efficiency measurements over a series of experimental tests, demonstrating whether certain tests result in long-term degradation or immediate catastrophic failures. Lastly, the result of this testing highlights the performance of MLPE units under the application of several accelerated environmental stressors.« less
Accelerated testing of module-level power electronics for long-term reliability
Flicker, Jack David; Tamizhmani, Govindasamy; Moorthy, Mathan Kumar; ...
2016-11-10
This work has applied a suite of long-term-reliability accelerated tests to a variety of module-level power electronics (MLPE) devices (such as microinverters and optimizers) from five different manufacturers. This dataset is one of the first (only the paper by Parker et al. entitled “Dominant factors affecting reliability of alternating current photovoltaic modules,” in Proc. 42nd IEEE Photovoltaic Spec. Conf., 2015, is reported for reliability testing in the literature), as well as the largest, experimental sets in public literature, both in the sample size (five manufacturers including both dc/dc and dc/ac units and 20 units for each test) and the numbermore » of experiments (six different experimental test conditions) for MLPE devices. The accelerated stress tests (thermal cycling test per IEC 61215 profile, damp heat test per IEC 61215 profile, and static temperature tests at 100 and 125 °C) were performed under powered and unpowered conditions. The first independent long-term experimental data regarding damp heat and grid transient testing, as well as the longest term (>9 month) testing of MLPE units reported in the literature for thermal cycling and high-temperature operating life, are included in these experiments. Additionally, this work is the first to show in situ power measurements, as well as periodic efficiency measurements over a series of experimental tests, demonstrating whether certain tests result in long-term degradation or immediate catastrophic failures. Lastly, the result of this testing highlights the performance of MLPE units under the application of several accelerated environmental stressors.« less
Study of advanced techniques for determining the long-term performance of components
NASA Technical Reports Server (NTRS)
1972-01-01
A study was conducted of techniques having the capability of determining the performance and reliability of components for spacecraft liquid propulsion applications for long term missions. The study utilized two major approaches; improvement in the existing technology, and the evolution of new technology. The criteria established and methods evolved are applicable to valve components. Primary emphasis was placed on the propellants oxygen difluoride and diborane combination. The investigation included analysis, fabrication, and tests of experimental equipment to provide data and performance criteria.
NEPP Evaluation of Automotive Grade Tantalum Chip Capacitors
NASA Technical Reports Server (NTRS)
Sampson, Mike; Brusse, Jay
2018-01-01
Automotive grade tantalum (Ta) chip capacitors are available at lower cost with smaller physical size and higher volumetric efficiency compared to military/space grade capacitors. Designers of high reliability aerospace and military systems would like to take advantage of these attributes while maintaining the high standards for long-term reliable operation they are accustomed to when selecting military-qualified established reliability tantalum chip capacitors (e.g., MIL-PRF-55365). The objective for this evaluation was to assess the long-term performance of off-the-shelf automotive grade Ta chip capacitors (i.e., manufacturer self-qualified per AEC Q-200). Two (2) lots of case size D manganese dioxide (MnO2) cathode Ta chip capacitors from 1 manufacturer were evaluated. The evaluation consisted of construction analysis, basic electrical parameter characterization, extended long-term (2000 hours) life testing and some accelerated stress testing. Tests and acceptance criteria were based upon manufacturer datasheets and the Automotive Electronics Council's AEC Q-200 qualification specification for passive electronic components. As-received a few capacitors were marginally above the specified tolerance for capacitance and ESR. X-ray inspection found that the anodes for some devices may not be properly aligned within the molded encapsulation leaving less than 1 mil thickness of the encapsulation. This evaluation found that the long-term life performance of automotive grade Ta chip capacitors is generally within specification limits suggesting these capacitors may be suitable for some space applications.
Arcjet starting reliability - A multistart test on hydrogen/nitrogen mixtures
NASA Technical Reports Server (NTRS)
Haag, Thomas W.; Curran, Frank M.
1987-01-01
An arcjet starting reliability test was performed to investigate one feasibility issue in the use of arcjets on board a satellite for north-south stationkeeping. A 1 kW arcjet was run on hydrogen/nitrogen gas mixtures simulating decomposed hydrazine. A pulse width modulated power supply with an integral high voltage starting pulser was used for arc ignition and steady-state operation. The test was performed in four phases in order to determine if starting characteristics changed as a result of long term thruster operation. More than 300 successful starts were accumulated over an operating time of 18 hr. Overall results indicate that there is a link between starting characteristics and long term thruster operation; however, the large number of starts had no effect on steady-state performance.
Arcjet starting reliability: A multistart test on hydrogen/nitrogen mixtures
NASA Technical Reports Server (NTRS)
Haag, Thomas W.; Curran, Frank M.
1987-01-01
An arcjet starting reliability test was performed to investigate one feasibility issue in the use of arcjets onboard a satellite for north-south stationkeeping. A 1 kW arcjet was run on hydrogen/nitrogen gas mixtures simulating decomposed hydrazine. A pulse width modulated power supply with an integral high voltage starting pulser was used for arc ignition and steady-state operation. The test was performed in four phases in order to determine if starting characteristics changed as a result of long term thruster operation. More than 300 successful starts were accumulated over an operating time of 18 hrs. Overall results indicate that there is a link between starting characteristics and long term thruster operation; however, the large number of starts had no effect on steady-state performance.
Performance and Reliability of Quantum Cascade Lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myers, Tanya L.; Cannon, Bret D.; Taubman, Matthew S.
2013-05-01
We present the burn-in behavior and power stability of multiple quantum cascade lasers (QCLs) that were measured to investigate their long-term performance. For these experiments, the current to the QCL was cycled every ten minutes, and the output power was monitored over time for durations as long as two months. A small increase in power for a given injection current is observed for almost all of the QCLs tested during the burn-in period. The data from these experiments will be presented along with the effects of packaging the QCLs to determine the impact on performance and reliability.
Short- and long-term reliability of language fMRI.
Nettekoven, Charlotte; Reck, Nicola; Goldbrunner, Roland; Grefkes, Christian; Weiß Lucas, Carolin
2018-08-01
When using functional magnetic resonance imaging (fMRI) for mapping important language functions, a high test-retest reliability is mandatory, both in basic scientific research and for clinical applications. We, therefore, systematically tested the short- and long-term reliability of fMRI in a group of healthy subjects using a picture naming task and a sparse-sampling fMRI protocol. We hypothesized that test-retest reliability might be higher for (i) speech-related motor areas than for other language areas and for (ii) the short as compared to the long intersession interval. 16 right-handed subjects (mean age: 29 years) participated in three sessions separated by 2-6 (session 1 and 2, short-term) and 21-34 days (session 1 and 3, long-term). Subjects were asked to perform the same overt picture naming task in each fMRI session (50 black-white images per session). Reliability was tested using the following measures: (i) Euclidean distances (ED) between local activation maxima and Centers of Gravity (CoGs), (ii) overlap volumes and (iii) voxel-wise intraclass correlation coefficients (ICCs). Analyses were performed for three regions of interest which were chosen based on whole-brain group data: primary motor cortex (M1), superior temporal gyrus (STG) and inferior frontal gyrus (IFG). Our results revealed that the activation centers were highly reliable, independent of the time interval, ROI or hemisphere with significantly smaller ED for the local activation maxima (6.45 ± 1.36 mm) as compared to the CoGs (8.03 ± 2.01 mm). In contrast, the extent of activation revealed rather low reliability values with overlaps ranging from 24% (IFG) to 56% (STG). Here, the left hemisphere showed significantly higher overlap volumes than the right hemisphere. Although mean ICCs ranged between poor (ICC<0.5) and moderate (ICC 0.5-0.74) reliability, highly reliable voxels (ICC>0.75) were found for all ROIs. Voxel-wise reliability of the different ROIs was influenced by the intersession interval. Taken together, we could show that, despite of considerable ROI-dependent variations of the extent of activation over time, highly reliable centers of activation can be identified using an overt picture naming paradigm. Copyright © 2018 Elsevier Inc. All rights reserved.
COTS Ceramic Chip Capacitors: An Evaluation of the Parts and Assurance Methodologies
NASA Technical Reports Server (NTRS)
Brusse, Jay A.; Sampson, Michael J.
2004-01-01
Commercial-Off-The-Shelf (COTS) multilayer ceramic chip capacitors (MLCCs) are continually evolving to reduce physical size and increase volumetric efficiency. Designers of high reliability aerospace and military systems are attracted to these attributes of COTS MLCCs and would like to take advantage of them while maintaining the high standards for long-term reliable operation they are accustomed io when selecting military qualified established reliability (MIL-ER) MLCCs. However, MIL-ER MLCCs are not available in the full range of small chip sizes with high capacitance as found in today's COTS MLCCs. The objectives for this evaluation were to assess the long-term performance of small case size COTS MLCCs and to identify effective, lower-cost product assurance methodologies. Fifteen (15) lots of COTS X7R dielectric MLCCs from four (4) different manufacturers and two (2) MIL-ER BX dielectric MLCCs from two (2) of the same manufacturers were evaluated. Both 0805 and 0402 chip sizes were included. Several voltage ratings were tested ranging from a high of 50 volts to a low of 6.3 volts. The evaluation consisted of a comprehensive screening and qualification test program based upon MIL-PRF-55681 (i.e., voltage conditioning, thermal shock, moisture resistance, 2000-hour life test, etc.). In addition, several lot characterization tests were performed including Destructive Physical Analysis (DPA), Highly Accelerated Life Test (HALT) and Dielectric Voltage Breakdown Strength. The data analysis included a comparison of the 2000-hour life test results (used as a metric for long-term performance) relative to the screening and characterization test results. Results of this analysis indicate that the long-term life performance of COTS MLCCs is variable -- some lots perform well, some lots perform poorly. DPA and HALT were found to be promising lot characterization tests to identify substandard COTS MLCC lots prior to conducting more expensive screening and qualification tests. The results indicate that lot- specific screening and qualification are still recommended for high reliability applications. One significant and concerning observation is that MIL- type voltage conditioning (100 hours at twice rated voltage, 125 C) was not an effective screen in removing infant mortality parts for the particular lots of COTS MLCCs evaluated.
NASA Astrophysics Data System (ADS)
Wang, Chaoen; Chang, Lung-Hai; Chang, Mei-Hsia; Chen, Ling-Jhen; Chung, Fu-Tsai; Lin, Ming-Chyuan; Liu, Zong-Kai; Lo, Chih-Hung; Tsai, Chi-Lin; Yeh, Meng-Shu; Yu, Tsung-Chi
2017-11-01
Excitation of multipacting, enhanced by gas condensation on cold surfaces of the high power input coupler in a SRF module poses the highest challenge for reliable SRF operation under high average RF power. This could prevent the light source SRF module from being operated with a desired high beam current. Off-line long-term reliability tests have been conducted for the newly constructed 500-MHz SRF KEKB type modules at an accelerating RF voltage of 1.6-MV to enable prediction of their operational reliability in the 3-GeV Taiwan Photon Source (TPS), since prediction from mere production performance by conventional horizontal test is presently unreliable. As expected, operational difficulties resulting from multipacting, enhanced by gas condensation, have been identified in the course of long-term reliability test. Our present hypothesis is that gas condensation can be slowed down by preserving the vacuum pressure at the power coupler close to that reached just after its cool down to liquid helium temperatures. This is achievable by reduction of the power coupler out-gassing rate through comprehensive warm aging. Its feasibility and effectiveness has been experimentally verified in a second long term reliability test. Our success opens the possibility to operate the SRF module free of multipacting trouble and opens a new direction to improve the operational performance of next generation SRF modules in light sources with high beam currents.
On the short-term uncertainty in performance f a point absorber wave energy converter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coe, Ryan Geoffrey; Michelen, Carlos; Manuel, Lance
2016-03-01
Of interest, in this study, is the quantification of uncertainty in the performance of a two-body wave point absorber (Reference Model 3 or RM3), which serves as a wave energy converter (WEC). We demonstrate how simulation tools may be used to establish short-term relationships between any performance parameter of the WEC device and wave height in individual sea states. We demonstrate this methodology for two sea states. Efficient structural reliability methods, validated using more expensive Monte Carlo sampling, allow the estimation of uncertainty in performance of the device. Such methods, when combined with metocean data quantifying the likelihood of differentmore » sea states, can be useful in long-term studies and in reliability-based design.« less
Long-term Outcomes of Operative and Nonoperative Treatment of Congenital Coxa Vara.
Roberts, David W; Saglam, Yavuz; De La Rocha, Adriana; Frasquillo, Brigid N; Tulchin-Francis, Kirsten; Kim, Harry K W
2018-04-01
Congenital coxa vara (CCV) is a rare hip condition with few long-term studies. The purpose of this study was to assess clinical, radiographic, and functional outcomes after operative and nonoperative treatment of CCV, assess reliability of radiographic parameters, and investigate risk factors for recurrence after surgery. Retrospective review was performed of all CCV patients treated at 1 institution from 1980 to 2010. In addition, patients were recalled for additional follow-up x-rays, modified Harris Hip Score (mHHS), and gait analysis. Radiographic measurements [neck-shaft angle (NSA), head-shaft angle (HSA), Hilgenreiner-epiphyseal angle (HEA), and femoral neck length (FNL)] were assessed for reliability using intraclass correlation coefficients. Multivariate analysis was performed to identify risk factors for recurrence after surgery. Forty-six hips in 32 patients were reviewed. Mean age at presentation was 5.4±4.9 years. Mean follow-up was 11.8±5.8 years. Valgus proximal femoral osteotomy was performed in 27 hips (20 patients). Initial deformity was greater in the operative group (NSA 90±17 degrees, HEA 68±19 degrees) versus nonoperative patients (NSA 122±19 degrees, HEA 34±14 degrees) (P<0.0001), but radiographic outcomes were similar at follow-up. Most nonoperative hips had normal FNL growth rates (80%), but resolution of varus NSA occurred in only 21%. In contrast, 56% of operative hips showed decreased FNL growth rates. Interobserver reliability was excellent for HEA (0.98), NSA (0.90), and FNL (0.89), and good for HSA (0.79). Repeat osteotomy was performed in 6 cases (22%). No significant predictors for recurrence were identified. At long-term follow-up for recalled patients, 72% had significantly abnormal gait, and 50% had fair-poor functional outcomes (mHHS<79). Valgus osteotomy corrects severe deformity in CCV with improved clinical and radiographic outcomes. HEA and NSA are the most reliable radiographic measurements of proximal femoral deformity in CCV. Recurrence is not uncommon, but no predictors were identified. Many patients have persistent gait abnormalities and functional impairment at long-term follow-up, regardless of prior treatment. Level III-retrospective cohort.
Individual styles of professional operator's performance for the needs of interplanetary mission.
NASA Astrophysics Data System (ADS)
Boritko, Yaroslav; Gushin, Vadim; Zavalko, Irina; Smoleevskiy, Alexandr; Dudukin, Alexandr
Maintenance of the cosmonaut’s professional performance reliability is one of the priorities of long-term space flights safety. Cosmonaut’s performance during long-term space flight decreases due to combination of the microgravity effects and inevitable degradation of skills during prolonged breaks in training. Therefore, the objective of the elaboration of countermeasures against skill decrement is very relevant. During the experiment with prolonged isolation "Mars-500" in IMBP two virtual models of professional operator’s activities were used to investigate the influence of extended isolation, monotony and confinement on professional skills degradation. One is well-known “PILOT-1” (docking to the space station), another - "VIRTU" (manned operations of planet exploration). Individual resistance to the artificial sensory conflict was estimated using computerized version of “Mirror koordinograf” with GSR registration. Two different individual performance styles, referring to the different types of response to stress, have been identified. Individual performance style, called "conservative control", manifested in permanent control of parameters, conditions and results of the operator’s activity. Operators with this performance style demonstrate high reliability in performing tasks. The drawback of the style is intensive resource expenditure - both the operator (physiological "cost") and the technical system operated (fuel, time). This style is more efficient while executing tasks that require long work with high reliability required according to a detailed protocol, such as orbital flight. Individual style, called "exploratory ", manifested in the search of new ways of task fulfillment. This style is accompanied by partial, periodic lack of control of the conditions and result of operator’s activity due to flexible approach to the tasks perfect implementation. Operators spent less resource (fuel, time, lower physiological "cost") due to high self-regulation in tasks not requiring high reliability. "Exploratory" style is more effective when working in nonregulated and off-nominal situations, such as interplanetary mission, due to possibility to use nonstandard innovative solutions, save physiological resources and rapidly mobilize to demonstrate high reliability at key moments.
Post-Test Analysis of a 10-Year Sodium Heat Pipe Life Test
NASA Technical Reports Server (NTRS)
Rosenfeld, John H.; Locci, Ivan E.; Sanzi, James L.; Hull, David R.; Geng, Steven M.
2011-01-01
High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 years) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described. Lessons learned and future life test plans are also discussed.
NASA Technical Reports Server (NTRS)
Rosenfeld, John, H; Minnerly, Kenneth, G; Dyson, Christopher, M.
2012-01-01
High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 yr) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described.
Accelerated Test Method for Corrosion Protective Coatings Project
NASA Technical Reports Server (NTRS)
Falker, John; Zeitlin, Nancy; Calle, Luz
2015-01-01
This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.
Norman, J C; McGee, M G; Fuqua, J M; Igo, S R; Turner, S A; Sterling, R; Urrutia, C O; Frazier, O H; Clay, W C; Chambers, J A
1983-02-01
A long-term, implantable, electrically actuated left ventricular assist system (THI/Gould LVAS) is being developed and characterized in vitro and in vivo for utilization in patients with end-stage heart disease. This system consists of five major components: a long-term, implantable blood pump (THI E-type ALVAD); an electrical-mechanical energy converter (Gould Model V); a control unit with batteries; a volume compensation system; and an external power supply and monitoring unit. Two of these components (blood pump and electrical-mechanical energy converter) have been integrated, and are undergoing chronic in vivo evaluations in calves. Thus far, 44 pneumatically and electrically actuated THI/Gould LVAS evaluations have been performed. This experience has resulted in greater than 6.5 years of actuation in vivo, with durations exceeding 1 year. System in vivo performance in terms of durability, mechanical reliability, hemodynamic effectiveness, and biocompatibility has been satisfactory. Demonstration of long-term (2-year) effectiveness in supporting the circulation is the ultimate goal.
Product Reliability Trends, Derating Considerations and Failure Mechanisms with Scaled CMOS
NASA Technical Reports Server (NTRS)
White, Mark; Vu, Duc; Nguyen, Duc; Ruiz, Ron; Chen, Yuan; Bernstein, Joseph B.
2006-01-01
As microelectronics is scaled into the deep sub-micron regime, space and aerospace users of advanced technology CMOS are reassessing how scaling effects impact long-term product reliability. The effects of electromigration (EM), time-dependent-dielectric-breakdown (TDDB) and hot carrier degradation (HCI and NBTI) wearout mechanisms on scaled technologies and product reliability are investigated, accelerated stress testing across several technology nodes is performed, and FA is conducted to confirm the failure mechanism(s).
David Ray; Chad Keyser; Robert Seymour; John Brissette
2008-01-01
Forest managers are increasingly called upon to provide long-term predictions of forest development. The dynamics of regeneration establishment, survival and subsequent recruitment of established seedlings to larger size classes is a critical component of these forecasts, yet remains a weak link in available models. To test the reliability of FVS-NE for simulating...
Accuracy Of LTPP Traffic Loading Estimates
DOT National Transportation Integrated Search
1998-07-01
The accuracy and reliability of traffic load estimates are key to determining a pavement's life expectancy. To better understand the variability of traffic loading rates and its effect on the accuracy of the Long Term Pavement Performance (LTPP) prog...
Long Term Performance Metrics of the GD SDR on the SCaN Testbed: The First Year on the ISS
NASA Technical Reports Server (NTRS)
Nappier, Jennifer; Wilson, Molly C.
2014-01-01
The General Dynamics (GD) S-Band software defined radio (SDR) in the Space Communications and Navigation (SCaN) Testbed on the International Space Station (ISS) provides experimenters an opportunity to develop and demonstrate experimental waveforms in space. The SCaN Testbed was installed on the ISS in August of 2012. After installation, the initial checkout and commissioning phases were completed and experimental operations commenced. One goal of the SCaN Testbed is to collect long term performance metrics for SDRs operating in space in order to demonstrate long term reliability. These metrics include the time the SDR powered on, the time the power amplifier (PA) is powered on, temperature trends, error detection and correction (EDAC) behavior, and waveform operational usage time. This paper describes the performance of the GD SDR over the first year of operations on the ISS.
Detecting long-term growth trends using tree rings: a critical evaluation of methods.
Peters, Richard L; Groenendijk, Peter; Vlam, Mart; Zuidema, Pieter A
2015-05-01
Tree-ring analysis is often used to assess long-term trends in tree growth. A variety of growth-trend detection methods (GDMs) exist to disentangle age/size trends in growth from long-term growth changes. However, these detrending methods strongly differ in approach, with possible implications for their output. Here, we critically evaluate the consistency, sensitivity, reliability and accuracy of four most widely used GDMs: conservative detrending (CD) applies mathematical functions to correct for decreasing ring widths with age; basal area correction (BAC) transforms diameter into basal area growth; regional curve standardization (RCS) detrends individual tree-ring series using average age/size trends; and size class isolation (SCI) calculates growth trends within separate size classes. First, we evaluated whether these GDMs produce consistent results applied to an empirical tree-ring data set of Melia azedarach, a tropical tree species from Thailand. Three GDMs yielded similar results - a growth decline over time - but the widely used CD method did not detect any change. Second, we assessed the sensitivity (probability of correct growth-trend detection), reliability (100% minus probability of detecting false trends) and accuracy (whether the strength of imposed trends is correctly detected) of these GDMs, by applying them to simulated growth trajectories with different imposed trends: no trend, strong trends (-6% and +6% change per decade) and weak trends (-2%, +2%). All methods except CD, showed high sensitivity, reliability and accuracy to detect strong imposed trends. However, these were considerably lower in the weak or no-trend scenarios. BAC showed good sensitivity and accuracy, but low reliability, indicating uncertainty of trend detection using this method. Our study reveals that the choice of GDM influences results of growth-trend studies. We recommend applying multiple methods when analysing trends and encourage performing sensitivity and reliability analysis. Finally, we recommend SCI and RCS, as these methods showed highest reliability to detect long-term growth trends. © 2014 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Scheidegger, Robert J.; Lauenstein, Jean-Marie; Casey, Megan; Scheick, Leif; Hammoud, Ahmad
2013-01-01
Power systems designed for use in NASA space missions are required to work reliably under harsh conditions including radiation, thermal cycling, and extreme temperature exposures. Silicon carbide devices show great promise for use in future power electronics systems, but information pertaining to performance of the devices in the space environment is very scarce. A silicon carbide N-channel enhancement-mode power MOSFET called the CMF20120 is of interest for use in space environments. Samples of the device were exposed to radiation followed by long-term thermal cycling to address their reliability for use in space applications. The results of the experimental work are presentd and discussed.
Optical frequency standard development in support of NASA's gravity-mapping missions
NASA Technical Reports Server (NTRS)
Klipstein, W. M.; Seidel, D. J.; White, J. A.; Young, B. C.
2001-01-01
We intend to combine the exquisite performance over short time scales coming from a cavity reference with the long-term stability of an atomic frequency standard with an eye towards reliability in a spaceflight application.
Space Station Engineering and Technology Development
NASA Technical Reports Server (NTRS)
1985-01-01
The evolving space station program will be examined through a series of more specific studies: maintainability; research and technology in space; solar thermodynamics research and technology; program performance; onboard command and control; and research and technology road maps. The purpose is to provide comments on approaches to long-term, reliable operation at low cost in terms of funds and crew time.
How to Characterize the Reliability of Ceramic Capacitors with Base-Metal Electrodes (BMEs)
NASA Technical Reports Server (NTRS)
Liu, David (Donhang)
2015-01-01
The reliability of an MLCC device is the product of a time-dependent part and a time-independent part: 1) Time-dependent part is a statistical distribution; 2) Time-independent part is the reliability at t=0, the initial reliability. Initial reliability depends only on how a BME MLCC is designed and processed. Similar to the way the minimum dielectric thickness ensured the long-term reliability of a PME MLCC, the initial reliability also ensures the long term-reliability of a BME MLCC. This presentation shows new discoveries regarding commonalities and differences between PME and BME capacitor technologies.
How to Characterize the Reliability of Ceramic Capacitors with Base-Metal Electrodes (BMEs)
NASA Technical Reports Server (NTRS)
Liu, Donhang
2015-01-01
The reliability of an MLCC device is the product of a time-dependent part and a time-independent part: 1) Time-dependent part is a statistical distribution; 2) Time-independent part is the reliability at t0, the initial reliability. Initial reliability depends only on how a BME MLCC is designed and processed. Similar to the way the minimum dielectric thickness ensured the long-term reliability of a PME MLCC, the initial reliability also ensures the long term-reliability of a BME MLCC. This presentation shows new discoveries regarding commonalities and differences between PME and BME capacitor technologies.
NASA Astrophysics Data System (ADS)
Cheng, Xiao; Feng, Lei; Zhou, Fanqin; Wei, Lei; Yu, Peng; Li, Wenjing
2018-02-01
With the rapid development of the smart grid, the data aggregation point (AP) in the neighborhood area network (NAN) is becoming increasingly important for forwarding the information between the home area network and wide area network. Due to limited budget, it is unable to use one-single access technology to meet the ongoing requirements on AP coverage. This paper first introduces the wired and wireless hybrid access network with the integration of long-term evolution (LTE) and passive optical network (PON) system for NAN, which allows a good trade-off among cost, flexibility, and reliability. Then, based on the already existing wireless LTE network, an AP association optimization model is proposed to make the PON serve as many APs as possible, considering both the economic efficiency and network reliability. Moreover, since the features of the constraints and variables of this NP-hard problem, a hybrid intelligent optimization algorithm is proposed, which is achieved by the mixture of the genetic, ant colony and dynamic greedy algorithm. By comparing with other published methods, simulation results verify the performance of the proposed method in improving the AP coverage and the performance of the proposed algorithm in terms of convergence.
Exploiting New Data Sources to Quantify Arterial Congestion and Performance Measures.
DOT National Transportation Integrated Search
2017-01-01
Transit travel time, operating speed and reliability all influence service attractiveness, operating cost and system efficiency. These metrics have a long-term impact on system effectiveness through a change in ridership. As part of its bus dispatch ...
Integrated performance and reliability specification for digital avionics systems
NASA Technical Reports Server (NTRS)
Brehm, Eric W.; Goettge, Robert T.
1995-01-01
This paper describes an automated tool for performance and reliability assessment of digital avionics systems, called the Automated Design Tool Set (ADTS). ADTS is based on an integrated approach to design assessment that unifies traditional performance and reliability views of system designs, and that addresses interdependencies between performance and reliability behavior via exchange of parameters and result between mathematical models of each type. A multi-layer tool set architecture has been developed for ADTS that separates the concerns of system specification, model generation, and model solution. Performance and reliability models are generated automatically as a function of candidate system designs, and model results are expressed within the system specification. The layered approach helps deal with the inherent complexity of the design assessment process, and preserves long-term flexibility to accommodate a wide range of models and solution techniques within the tool set structure. ADTS research and development to date has focused on development of a language for specification of system designs as a basis for performance and reliability evaluation. A model generation and solution framework has also been developed for ADTS, that will ultimately encompass an integrated set of analytic and simulated based techniques for performance, reliability, and combined design assessment.
Building professional capacity in ITS : guidelines on developing the future professional
DOT National Transportation Integrated Search
1999-07-01
Time domain reflectometry (TDR) has become one of the most reliable methods for measuring in-situ soil moisture content. TDR sensors developed by the Federal Highway Administration (FHWA) are being used in the Long-Term Pavement Performance (LTPP) Se...
They saw a movie: long-term memory for an extended audiovisual narrative.
Furman, Orit; Dorfman, Nimrod; Hasson, Uri; Davachi, Lila; Dudai, Yadin
2007-06-01
We measured long-term memory for a narrative film. During the study session, participants watched a 27-min movie episode, without instructions to remember it. During the test session, administered at a delay ranging from 3 h to 9 mo after the study session, long-term memory for the movie was probed using a computerized questionnaire that assessed cued recall, recognition, and metamemory of movie events sampled approximately 20 sec apart. The performance of each group of participants was measured at a single time point only. The participants remembered many events in the movie even months after watching it. Analysis of performance, using multiple measures, indicates differences between recent (weeks) and remote (months) memory. While high-confidence recognition performance was a reliable index of memory throughout the measured time span, cued recall accuracy was higher for relatively recent information. Analysis of different content elements in the movie revealed differential memory performance profiles according to time since encoding. We also used the data to propose lower limits on the capacity of long-term memory. This experimental paradigm is useful not only for the analysis of behavioral performance that results from encoding episodes in a continuous real-life-like situation, but is also suitable for studying brain substrates and processes of real-life memory using functional brain imaging.
They saw a movie: Long-term memory for an extended audiovisual narrative
Furman, Orit; Dorfman, Nimrod; Hasson, Uri; Davachi, Lila; Dudai, Yadin
2007-01-01
We measured long-term memory for a narrative film. During the study session, participants watched a 27-min movie episode, without instructions to remember it. During the test session, administered at a delay ranging from 3 h to 9 mo after the study session, long-term memory for the movie was probed using a computerized questionnaire that assessed cued recall, recognition, and metamemory of movie events sampled ∼20 sec apart. The performance of each group of participants was measured at a single time point only. The participants remembered many events in the movie even months after watching it. Analysis of performance, using multiple measures, indicates differences between recent (weeks) and remote (months) memory. While high-confidence recognition performance was a reliable index of memory throughout the measured time span, cued recall accuracy was higher for relatively recent information. Analysis of different content elements in the movie revealed differential memory performance profiles according to time since encoding. We also used the data to propose lower limits on the capacity of long-term memory. This experimental paradigm is useful not only for the analysis of behavioral performance that results from encoding episodes in a continuous real-life-like situation, but is also suitable for studying brain substrates and processes of real-life memory using functional brain imaging. PMID:17562897
Deep Space Optical Link ARQ Performance Analysis
NASA Technical Reports Server (NTRS)
Clare, Loren; Miles, Gregory
2016-01-01
Substantial advancements have been made toward the use of optical communications for deep space exploration missions, promising a much higher volume of data to be communicated in comparison with present -day Radio Frequency (RF) based systems. One or more ground-based optical terminals are assumed to communicate with the spacecraft. Both short-term and long-term link outages will arise due to weather at the ground station(s), space platform pointing stability, and other effects. To mitigate these outages, an Automatic Repeat Query (ARQ) retransmission method is assumed, together with a reliable back channel for acknowledgement traffic. Specifically, the Licklider Transmission Protocol (LTP) is used, which is a component of the Disruption-Tolerant Networking (DTN) protocol suite that is well suited for high bandwidth-delay product links subject to disruptions. We provide an analysis of envisioned deep space mission scenarios and quantify buffering, latency and throughput performance, using a simulation in which long-term weather effects are modeled with a Gilbert -Elliot Markov chain, short-term outages occur as a Bernoulli process, and scheduled outages arising from geometric visibility or operational constraints are represented. We find that both short- and long-term effects impact throughput, but long-term weather effects dominate buffer sizing and overflow losses as well as latency performance.
Dolezel, R; Ryska, O; Kollar, M; Juhasova, J; Kalvach, J; Ryska, M; Martinek, J
2016-11-01
Both over-the-scope clip (OTSC) and KING (endoloop + clips) closures provide reliable and safe full-thickness endoscopic closure. Nevertheless, OTSC clip demonstrated significantly inferior histological healing in the short-term follow-up. To compare OTSC versus KING closure of a perforation with regard to long-term effectiveness and macroscopic and histological quality of healing. We performed a randomized experimental study with 16 mini-pigs (mean weight 43.2 ± 11.2 kg). A standardized perforation was performed on the anterior sigmoid wall. KING closure (n = 8) was attained by approximation of an endoloop fixed to the margins of a perforation with endoclips. OTSC closure (n = 8) was performed by deploying OTSC (OVESCO) over the defect. Pigs underwent a control sigmoidoscopy 8 months after the closure to assess the macroscopic quality of healing. Then, autopsy was performed and the rectosigmoid was sent for histopathological assessment. All closures were completed successfully without air leaks. The duration of closure was similar in both techniques (OTSC 17.8 ± 7.6 min vs. KING 19.6 ± 8.8 min). At autopsy, all KING closures (100 %) were healed with a flat scar without signs of leakage. Microscopically, no inflammatory changes were observed after KING closure. In the OTSC group, microscopic ulcers were present in two pigs (25 %), cryptal abscesses in three pigs (38 %) and significant neutrophil accumulation in all eight pigs (P < 0.01). Giant cell granulomas, dysplasia or abundant scarification was not observed in either group. Both OTSC and KING closures offer a long-term reliable seal of a gastrointestinal perforation without stenosis or fistulas. KING closure provides long-term histologically superior healing.
NASA Astrophysics Data System (ADS)
Lee, Tae-Kyu; Ma, Hongtao; Liu, Kuo-Chuan; Xue, Jie
2010-12-01
The interaction between isothermal aging and the long-term reliability of fine-pitch ball grid array (BGA) packages with Sn-3.0Ag-0.5Cu (wt.%) solder ball interconnects was investigated. In this study, 0.4-mm fine-pitch packages with 300- μm-diameter Sn-Ag-Cu solder balls were used. Two different package substrate surface finishes were selected to compare their effects on the final solder composition, especially the effect of Ni, during thermal cycling. To study the impact on thermal performance and long-term reliability, samples were isothermally aged and thermally cycled from 0°C to 100°C with 10 min dwell time. Based on Weibull plots for each aging condition, package lifetime was reduced by approximately 44% by aging at 150°C. Aging at 100°C showed a smaller impact but similar trend. The microstructure evolution was observed during thermal aging and thermal cycling with different phase microstructure transformations between electrolytic Ni/Au and organic solderability preservative (OSP) surface finishes, focusing on the microstructure evolution near the package-side interface. Different mechanisms after aging at various conditions were observed, and their impacts on the fatigue lifetime of solder joints are discussed.
Schlagbauer, Bernhard; Mink, Maurice; Müller, Hermann J; Geyer, Thomas
2017-02-01
Observers are able to resume an interrupted search trial faster relative to responding to a new, unseen display. This finding of rapid resumption is attributed to short-term perceptual hypotheses generated on the current look and confirmed upon subsequent looks at the same display. It has been suggested that the contents of perceptual hypotheses are similar to those of other forms of memory acquired long-term through repeated exposure to the same search displays over the course of several trials, that is, the memory supporting "contextual cueing." In three experiments, we investigated the relationship between short-term perceptual hypotheses and long-term contextual memory. The results indicated that long-term, contextual memory of repeated displays neither affected the generation nor the confirmation of short-term perceptual hypotheses for these displays. Furthermore, the analysis of eye movements suggests that long-term memory provides an initial benefit in guiding attention to the target, whereas in subsequent looks guidance is entirely based on short-term perceptual hypotheses. Overall, the results reveal a picture of both long- and short-term memory contributing to reliable performance gains in interrupted search, while exerting their effects in an independent manner.
Tian, Qinglin; Salcic, Zoran; Wang, Kevin I-Kai; Pan, Yun
2015-12-05
Pedestrian dead reckoning is a common technique applied in indoor inertial navigation systems that is able to provide accurate tracking performance within short distances. Sensor drift is the main bottleneck in extending the system to long-distance and long-term tracking. In this paper, a hybrid system integrating traditional pedestrian dead reckoning based on the use of inertial measurement units, short-range radio frequency systems and particle filter map matching is proposed. The system is a drift-free pedestrian navigation system where position error and sensor drift is regularly corrected and is able to provide long-term accurate and reliable tracking. Moreover, the whole system is implemented on a commercial off-the-shelf smartphone and achieves real-time positioning and tracking performance with satisfactory accuracy.
Synaptic Transmission Optimization Predicts Expression Loci of Long-Term Plasticity.
Costa, Rui Ponte; Padamsey, Zahid; D'Amour, James A; Emptage, Nigel J; Froemke, Robert C; Vogels, Tim P
2017-09-27
Long-term modifications of neuronal connections are critical for reliable memory storage in the brain. However, their locus of expression-pre- or postsynaptic-is highly variable. Here we introduce a theoretical framework in which long-term plasticity performs an optimization of the postsynaptic response statistics toward a given mean with minimal variance. Consequently, the state of the synapse at the time of plasticity induction determines the ratio of pre- and postsynaptic modifications. Our theory explains the experimentally observed expression loci of the hippocampal and neocortical synaptic potentiation studies we examined. Moreover, the theory predicts presynaptic expression of long-term depression, consistent with experimental observations. At inhibitory synapses, the theory suggests a statistically efficient excitatory-inhibitory balance in which changes in inhibitory postsynaptic response statistics specifically target the mean excitation. Our results provide a unifying theory for understanding the expression mechanisms and functions of long-term synaptic transmission plasticity. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Navstar Global Positioning System (GPS) clock program: Present and future
NASA Technical Reports Server (NTRS)
Tennant, D. M.
1981-01-01
Global Positioning System (GPS) program status are discussed and plans for ensuring the long term continuation of the program are presented. Performance of GPS clocks is presented in terms of on orbit data as portrayed by GPS master control station kalman filter processing. The GPS Clock reliability program is reviewed in depth and future plans fo the overall clock program are published.
Performance limiting processes in room temperature thallium bromide radiation detectors
NASA Astrophysics Data System (ADS)
Datta, Amlan; Becla, Piotr; Moed, Demi; Motakef, Shariar
2015-09-01
Thallium Bromide (TlBr) is a promising room-temperature radiation detector candidate with excellent charge transport properties. However, several critical issues are needed to be addressed before deployment of this material for long-term field applications. In this paper, the relevance and, scientific and technological progress made towards solving these challenges for TlBr have been discussed. The possible research pathways to mitigate the concerns related to this material have been analyzed and clearly established. Findings from novel experiments performed at CapeSym have revealed that the most significant factors for achieving long-term performance stability for TlBr devices involve physical and chemical conditions of the surface, residual stress, and choice of metal contacts. Palladium electrodes on TlBr devices resulted in a 20-fold improvement in the device lifetime when compared to its Br-etched Pt counterpart. Electron and hole contributions towards the spectroscopic response of the TlBr detector significantly depend on the interaction position of the incoming radiation and was clearly observed in this study. TlBr device fabrication techniques need significant improvement in order to attain reliable, repeatable, and stable, long-term performance.
NASA Technical Reports Server (NTRS)
Dunham, J. R. (Editor); Knight, J. C. (Editor)
1982-01-01
The state of the art in the production of crucial software for flight control applications was addressed. The association between reliability metrics and software is considered. Thirteen software development projects are discussed. A short term need for research in the areas of tool development and software fault tolerance was indicated. For the long term, research in format verification or proof methods was recommended. Formal specification and software reliability modeling, were recommended as topics for both short and long term research.
A Loss Tolerant Rate Controller for Reliable Multicast
NASA Technical Reports Server (NTRS)
Montgomery, Todd
1997-01-01
This paper describes the design, specification, and performance of a Loss Tolerant Rate Controller (LTRC) for use in controlling reliable multicast senders. The purpose of this rate controller is not to adapt to congestion (or loss) on a per loss report basis (such as per received negative acknowledgment), but instead to use loss report information and perceived state to decide more prudent courses of action for both the short and long term. The goal of this controller is to be responsive to congestion, but not overly reactive to spurious independent loss. Performance of the controller is verified through simulation results.
Ultracompliant Heterogeneous Copper-Tin Nanowire Arrays Making a Supersolder.
Gong, Wei; Li, Pengfei; Zhang, Yunheng; Feng, Xuhui; Major, Joshua; DeVoto, Douglas; Paret, Paul; King, Charles; Narumanchi, Sreekant; Shen, Sheng
2018-06-13
Due to the substantial increase in power density, thermal interface resistance that can constitute more than 50% of the total thermal resistance has generally become a bottleneck for thermal management in electronics. However, conventional thermal interface materials (TIMs) such as solder, epoxy, gel, and grease cannot fulfill the requirements of electronics for high-power and long-term operation. Here, we demonstrate a high-performance TIM consisting of a heterogeneous copper-tin nanowire array, which we term "supersolder" to emulate the role of conventional solders in bonding various surfaces. The supersolder is ultracompliant with a shear modulus 2-3 orders of magnitude lower than traditional solders and can reduce the thermal resistance by two times as compared with the state-of-the-art TIMs. This supersolder also exhibits excellent long-term reliability with >1200 thermal cycles over a wide temperature range. By resolving this critical thermal bottleneck, the supersolder enables electronic systems, ranging from microelectronics and portable electronics to massive data centers, to operate at lower temperatures with higher power density and reliability.
Creep-rupture reliability analysis
NASA Technical Reports Server (NTRS)
Peralta-Duran, A.; Wirsching, P. H.
1984-01-01
A probabilistic approach to the correlation and extrapolation of creep-rupture data is presented. Time temperature parameters (TTP) are used to correlate the data, and an analytical expression for the master curve is developed. The expression provides a simple model for the statistical distribution of strength and fits neatly into a probabilistic design format. The analysis focuses on the Larson-Miller and on the Manson-Haferd parameters, but it can be applied to any of the TTP's. A method is developed for evaluating material dependent constants for TTP's. It is shown that optimized constants can provide a significant improvement in the correlation of the data, thereby reducing modelling error. Attempts were made to quantify the performance of the proposed method in predicting long term behavior. Uncertainty in predicting long term behavior from short term tests was derived for several sets of data. Examples are presented which illustrate the theory and demonstrate the application of state of the art reliability methods to the design of components under creep.
Highly Survivable Avionics Systems for Long-Term Deep Space Exploration
NASA Technical Reports Server (NTRS)
Alkalai, L.; Chau, S.; Tai, A. T.
2001-01-01
The design of highly survivable avionics systems for long-term (> 10 years) exploration of space is an essential technology for all current and future missions in the Outer Planets roadmap. Long-term exposure to extreme environmental conditions such as high radiation and low-temperatures make survivability in space a major challenge. Moreover, current and future missions are increasingly using commercial technology such as deep sub-micron (0.25 microns) fabrication processes with specialized circuit designs, commercial interfaces, processors, memory, and other commercial off the shelf components that were not designed for long-term survivability in space. Therefore, the design of highly reliable, and available systems for the exploration of Europa, Pluto and other destinations in deep-space require a comprehensive and fresh approach to this problem. This paper summarizes work in progress in three different areas: a framework for the design of highly reliable and highly available space avionics systems, distributed reliable computing architecture, and Guarded Software Upgrading (GSU) techniques for software upgrading during long-term missions. Additional information is contained in the original extended abstract.
Jensen, Christian Gaden; Niclasen, Janni; Vangkilde, Signe Allerup; Petersen, Anders; Hasselbalch, Steen Gregers
2016-05-01
The Mindful Attention Awareness Scale (MAAS) measures perceived degree of inattentiveness in different contexts and is often used as a reversed indicator of mindfulness. MAAS is hypothesized to reflect a psychological trait or disposition when used outside attentional training contexts, but the long-term test-retest reliability of MAAS scores is virtually untested. It is unknown whether MAAS predicts psychological health after controlling for standardized socioeconomic status classifications. First, MAAS translated to Danish was validated psychometrically within a randomly invited healthy adult community sample (N = 490). Factor analysis confirmed that MAAS scores quantified a unifactorial construct of excellent composite reliability and consistent convergent validity. Structural equation modeling revealed that MAAS scores contributed independently to predicting psychological distress and mental health, after controlling for age, gender, income, socioeconomic occupational class, stressful life events, and social desirability (β = 0.32-.42, ps < .001). Second, MAAS scores showed satisfactory short-term test-retest reliability in 100 retested healthy university students. Finally, MAAS sample mean scores as well as individuals' scores demonstrated satisfactory test-retest reliability across a 6 months interval in the adult community (retested N = 407), intraclass correlations ≥ .74. MAAS scores displayed significantly stronger long-term test-retest reliability than scores measuring psychological distress (z = 2.78, p = .005). Test-retest reliability estimates did not differ within demographic and socioeconomic strata. Scores on the Danish MAAS were psychometrically validated in healthy adults. MAAS's inattentiveness scores reflected a unidimensional construct, long-term reliable disposition, and a factor of independent significance for predicting psychological health. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Probabilistic resource allocation system with self-adaptive capability
NASA Technical Reports Server (NTRS)
Yufik, Yan M. (Inventor)
1996-01-01
A probabilistic resource allocation system is disclosed containing a low capacity computational module (Short Term Memory or STM) and a self-organizing associative network (Long Term Memory or LTM) where nodes represent elementary resources, terminal end nodes represent goals, and directed links represent the order of resource association in different allocation episodes. Goals and their priorities are indicated by the user, and allocation decisions are made in the STM, while candidate associations of resources are supplied by the LTM based on the association strength (reliability). Reliability values are automatically assigned to the network links based on the frequency and relative success of exercising those links in the previous allocation decisions. Accumulation of allocation history in the form of an associative network in the LTM reduces computational demands on subsequent allocations. For this purpose, the network automatically partitions itself into strongly associated high reliability packets, allowing fast approximate computation and display of allocation solutions satisfying the overall reliability and other user-imposed constraints. System performance improves in time due to modification of network parameters and partitioning criteria based on the performance feedback.
National audit of continence care: laying the foundation.
Mian, Sarah; Wagg, Adrian; Irwin, Penny; Lowe, Derek; Potter, Jonathan; Pearson, Michael
2005-12-01
National audit provides a basis for establishing performance against national standards, benchmarking against other service providers and improving standards of care. For effective audit, clinical indicators are required that are valid, feasible to apply and reliable. This study describes the methods used to develop clinical indicators of continence care in preparation for a national audit. To describe the methods used to develop and test clinical indicators of continence care with regard to validity, feasibility and reliability. A multidisciplinary working group developed clinical indicators that measured the structure, process and outcome of care as well as case-mix variables. Literature searching, consensus workshops and a Delphi process were used to develop the indicators. The indicators were tested in 15 secondary care sites, 15 primary care sites and 15 long-term care settings. The process of development produced indicators that received a high degree of consensus within the Delphi process. Testing of the indicators demonstrated an internal reliability of 0.7 and an external reliability of 0.6. Data collection required significant investment in terms of staff time and training. The method used produced indicators that achieved a high degree of acceptance from health care professionals. The reliability of data collection was high for this audit and was similar to the level seen in other successful national audits. Data collection for the indicators was feasible to collect, however, issues of time and staffing were identified as limitations to such data collection. The study has described a systematic method for developing clinical indicators for national audit. The indicators proved robust and reliable in primary and secondary care as well as long-term care settings.
Using hybrid magnetic bearings to completely suspend the impeller of a ventricular assist device.
Khanwilkar, P; Olsen, D; Bearnson, G; Allaire, P; Maslen, E; Flack, R; Long, J
1996-06-01
Clinically available blood pumps and those under development suffer from poor mechanical reliability and poor biocompatibility related to anatomic fit, hemolysis, and thrombosis. To alleviate these problems concurrently in a long-term device is a substantial challenge. Based on testing the performance of a prototype, and on our judgment of desired characteristics, we have configured an innovative ventricular assist device, the CFVAD4, for long-term use. The design process and its outcome, the CFVAD4 system configuration, is described. To provide unprecedented reliability and biocompatibility, magnetic bearings completely suspend the rotating pump impeller. The CFVAD4 uses a combination of passive (permanent) and active (electric) magnetic bearings, a mixed flow impeller, and a slotless 3-phase brushless DC motor. These components are shaped, oriented, and integrated to provide a compact, implantable, pancake-shaped unit for placement in the left upper abdominal quadrant of adult humans.
A classification system for characterization of physical and non-physical work factors.
Genaidy, A; Karwowski, W; Succop, P; Kwon, Y G; Alhemoud, A; Goyal, D
2000-01-01
A comprehensive evaluation of work-related performance factors is a prerequisite to developing integrated and long-term solutions to workplace performance improvement. This paper describes a work-factor classification system that categorizes the entire domain of workplace factors impacting performance. A questionnaire-based instrument was developed to implement this classification system in industry. Fifty jobs were evaluated in 4 different service and manufacturing companies using the proposed questionnaire-based instrument. The reliability coefficients obtained from the analyzed jobs were considered good (0.589 to 0.862). In general, the physical work factors resulted in higher reliability coefficients (0.847 to 0.862) than non-physical work factors (0.589 to 0.768).
Psychometrics Matter in Health Behavior: A Long-term Reliability Generalization Study.
Pickett, Andrew C; Valdez, Danny; Barry, Adam E
2017-09-01
Despite numerous calls for increased understanding and reporting of reliability estimates, social science research, including the field of health behavior, has been slow to respond and adopt such practices. Therefore, we offer a brief overview of reliability and common reporting errors; we then perform analyses to examine and demonstrate the variability of reliability estimates by sample and over time. Using meta-analytic reliability generalization, we examined the variability of coefficient alpha scores for a well-designed, consistent, nationwide health study, covering a span of nearly 40 years. For each year and sample, reliability varied. Furthermore, reliability was predicted by a sample characteristic that differed among age groups within each administration. We demonstrated that reliability is influenced by the methods and individuals from which a given sample is drawn. Our work echoes previous calls that psychometric properties, particularly reliability of scores, are important and must be considered and reported before drawing statistical conclusions.
Environment assisted degradation mechanisms in advanced light metals
NASA Technical Reports Server (NTRS)
Gangloff, Richard P.; Stoner, Glenn E.; Swanson, Robert E.
1988-01-01
The general goals of the research program are to characterize alloy behavior quantitatively and to develop predictive mechanisms for environmental failure modes. Successes in this regard will provide the basis for metallurgical optimization of alloy performance, for chemical control of aggressive environments, and for engineering life prediction with damage tolerance and long term reliability.
Link-state-estimation-based transmission power control in wireless body area networks.
Kim, Seungku; Eom, Doo-Seop
2014-07-01
This paper presents a novel transmission power control protocol to extend the lifetime of sensor nodes and to increase the link reliability in wireless body area networks (WBANs). We first experimentally investigate the properties of the link states using the received signal strength indicator (RSSI). We then propose a practical transmission power control protocol based on both short- and long-term link-state estimations. Both the short- and long-term link-state estimations enable the transceiver to adapt the transmission power level and target the RSSI threshold range, respectively, to simultaneously satisfy the requirements of energy efficiency and link reliability. Finally, the performance of the proposed protocol is experimentally evaluated in two experimental scenarios-body posture change and dynamic body motion-and compared with the typical WBAN transmission power control protocols, a real-time reactive scheme, and a dynamic postural position inference mechanism. From the experimental results, it is found that the proposed protocol increases the lifetime of the sensor nodes by a maximum of 9.86% and enhances the link reliability by reducing the packet loss by a maximum of 3.02%.
Wang, Jin-Hui; Zuo, Xi-Nian; Gohel, Suril; Milham, Michael P.; Biswal, Bharat B.; He, Yong
2011-01-01
Graph-based computational network analysis has proven a powerful tool to quantitatively characterize functional architectures of the brain. However, the test-retest (TRT) reliability of graph metrics of functional networks has not been systematically examined. Here, we investigated TRT reliability of topological metrics of functional brain networks derived from resting-state functional magnetic resonance imaging data. Specifically, we evaluated both short-term (<1 hour apart) and long-term (>5 months apart) TRT reliability for 12 global and 6 local nodal network metrics. We found that reliability of global network metrics was overall low, threshold-sensitive and dependent on several factors of scanning time interval (TI, long-term>short-term), network membership (NM, networks excluding negative correlations>networks including negative correlations) and network type (NT, binarized networks>weighted networks). The dependence was modulated by another factor of node definition (ND) strategy. The local nodal reliability exhibited large variability across nodal metrics and a spatially heterogeneous distribution. Nodal degree was the most reliable metric and varied the least across the factors above. Hub regions in association and limbic/paralimbic cortices showed moderate TRT reliability. Importantly, nodal reliability was robust to above-mentioned four factors. Simulation analysis revealed that global network metrics were extremely sensitive (but varying degrees) to noise in functional connectivity and weighted networks generated numerically more reliable results in compared with binarized networks. For nodal network metrics, they showed high resistance to noise in functional connectivity and no NT related differences were found in the resistance. These findings provide important implications on how to choose reliable analytical schemes and network metrics of interest. PMID:21818285
NASA Astrophysics Data System (ADS)
Wisniewiski, David
2014-03-01
The need to quantify and to improve long-term stability of pressure transducers is a persistent requirement from the aerospace sector. Specifically, the incorporation of real-time pressure monitoring in aircraft landing gear, as exemplified in Tire Pressure Monitoring Systems (TPMS), has placed greater demand on the pressure transducer for improved performance and increased reliability which is manifested in low lifecycle cost and minimal maintenance downtime through fuel savings and increased life of the tire. Piezoresistive (PR) silicon MEMS pressure transducers are the primary choice as a transduction method for this measurement owing to their ability to be designed for the harsh environment seen in aircraft landing gear. However, these pressure transducers are only as valuable as the long-term stability they possess to ensure reliable, real-time monitoring over tens of years. The "heart" of the pressure transducer is the silicon MEMS element, and it is at this basic level where the long-term stability is established and needs to be quantified. A novel High Pressure, High Temperature (HPHT) vessel has been designed and constructed to facilitate this critical measurement of the silicon MEMS element directly through a process of mechanically "floating" the silicon MEMS element while being subjected to the extreme environments of pressure and temperature, simultaneously. Furthermore, the HPHT vessel is scalable to permit up to fifty specimens to be tested at one time to provide a statistically significant data population on which to draw reasonable conclusions on long-term stability. With the knowledge gained on the silicon MEMS element, higher level assembly to the pressure transducer envelope package can also be quantified as to the build-effects contribution to long-term stability in the same HPHT vessel due to its accommodating size. Accordingly, a HPHT vessel offering multiple levels of configurability and robustness in data measurement is presented, along with 10 year long-term stability results.
Mirjafari, Parissa; Baldwin, Susan A
2015-01-01
Successful operation of sulphate-reducing bioreactors using complex organic materials depends on providing a balance between more easily degrading material that achieves reasonable kinetics and low hydraulic retention times, and more slowly decomposing material that sustains performance in the long term. In this study, two organic mixtures containing the same ingredients typical of bioreactors used at mine sites (woodchips, hay and cow manure) but with different ratios of wood (recalcitrant) to hay (labile) were tested in six continuous flow bioreactors treating synthetic mine-affected water containing 600 mg/L of sulphate and 15 μg/L of selenium. The reactors were operated for short (5-6 months) and long (435-450 days) periods of time at the same hydraulic retention time of 15 days. There were no differences in the performance of the bioreactors in terms of sulphate-reduction over the short term, but the wood-rich bioreactors experienced variable and sometimes unreliable sulphate-reduction over the long term. Presence of more hay in the organic mixture was able to better sustain reliable performance. Production of dissolved organic compounds due to biodegradation within the bioreactors was detected for the first 175-230 days, after which their depletion coincided with a crash phase observed in the wood-rich bioreactors only.
NASA Technical Reports Server (NTRS)
Halford, Gary R.; Shah, Ashwin; Arya, Vinod K.; Krause, David L.; Bartolotta, Paul A.
2002-01-01
Deep-space missions require onboard electric power systems with reliable design lifetimes of up to 10 yr and beyond. A high-efficiency Stirling radioisotope power system is a likely candidate for future deep-space missions and Mars rover applications. To ensure ample durability, the structurally critical heater head of the Stirling power convertor has undergone extensive computational analyses of operating temperatures (up to 650 C), stresses, and creep resistance of the thin-walled Inconel 718 bill of material. Durability predictions are presented in terms of the probability of survival. A benchmark structural testing program has commenced to support the analyses. This report presents the current status of durability assessments.
High power diode lasers emitting from 639 nm to 690 nm
NASA Astrophysics Data System (ADS)
Bao, L.; Grimshaw, M.; DeVito, M.; Kanskar, M.; Dong, W.; Guan, X.; Zhang, S.; Patterson, J.; Dickerson, P.; Kennedy, K.; Li, S.; Haden, J.; Martinsen, R.
2014-03-01
There is increasing market demand for high power reliable red lasers for display and cinema applications. Due to the fundamental material system limit at this wavelength range, red diode lasers have lower efficiency and are more temperature sensitive, compared to 790-980 nm diode lasers. In terms of reliability, red lasers are also more sensitive to catastrophic optical mirror damage (COMD) due to the higher photon energy. Thus developing higher power-reliable red lasers is very challenging. This paper will present nLIGHT's released red products from 639 nm to 690nm, with established high performance and long-term reliability. These single emitter diode lasers can work as stand-alone singleemitter units or efficiently integrate into our compact, passively-cooled Pearl™ fiber-coupled module architectures for higher output power and improved reliability. In order to further improve power and reliability, new chip optimizations have been focused on improving epitaxial design/growth, chip configuration/processing and optical facet passivation. Initial optimization has demonstrated promising results for 639 nm diode lasers to be reliably rated at 1.5 W and 690nm diode lasers to be reliably rated at 4.0 W. Accelerated life-test has started and further design optimization are underway.
Forward Period Analysis Method of the Periodic Hamiltonian System.
Wang, Pengfei
2016-01-01
Using the forward period analysis (FPA), we obtain the period of a Morse oscillator and mathematical pendulum system, with the accuracy of 100 significant digits. From these results, the long-term [0, 1060] (time unit) solutions, ranging from the Planck time to the age of the universe, are computed reliably and quickly with a parallel multiple-precision Taylor series (PMT) scheme. The application of FPA to periodic systems can greatly reduce the computation time of long-term reliable simulations. This scheme provides an efficient way to generate reference solutions, against which long-term simulations using other schemes can be tested.
Phase transformation and long-term service of high-temperature martensitic chromium steels
NASA Astrophysics Data System (ADS)
Kalashnikov, I. S.; Tarasenko, L.; Acselrad, O.; Pereira, L. C.; Shalkevich, A.; Soboleva, G.
2000-02-01
Martensitic high Cr (10 - 16%) steels alloyed with Ni (Co), Mo, W, V, and N are widely used in constructions subjected to cyclic loads at temperatures up to 600 degrees Celsius, in general after quenching from 1100 - 1150 degrees Celsius followed by tempering at 650 - 690 degrees Celsius. Due to long term service exposure at high temperatures, different microstructural changes take place, such as second-phases precipitation, formation of low-angle grain boundaries, as well as internal damage caused by cyclic loads and creep. Specific phase diagrams are presented that can be used to define time periods for reliable operation of parts with given composition, based on the time required for the appearance of second phase particles known to be detrimental to mechanical strength and performance. Restoring thermal treatments to be applied after long time exposure at service conditions, aiming at increasing service life, are also presented and discussed. The combined use of the diagrams and the restoring treatment ensures prediction of a reliable service-life period for components made of these steels.
Phase transformation and long-term service of high-temperature martensitic chromium steels
NASA Astrophysics Data System (ADS)
Kalashnikov, I. S.; Tarasenko, L.; Acselrad, O.; Pereira, L. C.; Shalkevich, A.; Soboleva, G.
2001-02-01
Martensitic high Cr (10 - 16%) steels alloyed with Ni (Co), Mo, W, V, and N are widely used in constructions subjected to cyclic loads at temperatures up to 600 degrees Celsius, in general after quenching from 1100 - 1150 degrees Celsius followed by tempering at 650 - 690 degrees Celsius. Due to long term service exposure at high temperatures, different microstructural changes take place, such as second-phases precipitation, formation of low-angle grain boundaries, as well as internal damage caused by cyclic loads and creep. Specific phase diagrams are presented that can be used to define time periods for reliable operation of parts with given composition, based on the time required for the appearance of second phase particles known to be detrimental to mechanical strength and performance. Restoring thermal treatments to be applied after long time exposure at service conditions, aiming at increasing service life, are also presented and discussed. The combined use of the diagrams and the restoring treatment ensures prediction of a reliable service-life period for components made of these steels.
Effects of Thermal Cycling on Control and Irradiated EPC 2nd Generation GaN FETs
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Scheick, Leif; Lauenstein, Jean-Marie; Casey, Megan; Hammoud, Ahmad
2013-01-01
The power systems for use in NASA space missions must work reliably under harsh conditions including radiation, thermal cycling, and exposure to extreme temperatures. Gallium nitride semiconductors show great promise, but information pertaining to their performance is scarce. Gallium nitride N-channel enhancement-mode field effect transistors made by EPC Corporation in a 2nd generation of manufacturing were exposed to radiation followed by long-term thermal cycling in order to address their reliability for use in space missions. Results of the experimental work are presented and discussed.
Strength and reliability analysis of metal-composite overwrapped pressure vessel
NASA Astrophysics Data System (ADS)
Burov, A. E.; Lepikhin, A. M.; Moskvichev, V. V.
2017-12-01
Metal-composite overwrapped pressure vessels (MCOPV) have found a wide application in aerospace and aeronautical industries. Such vessels should combine impermeability and high weight efficiency with enhanced long-term safety and durability. To meet these requirements, theoretical and experimental studies on the mechanics of deformation and failure of MCOPV are required. In the paper, the analysis on strength, lifetime and reliability of MCOPV is presented. A high performance of the MCOPV is justified by comparing the calculation results with experiment data obtained on full-scale samples.
Highly Reliable PON Optical Splitters for Optical Access Networks in Outside Environments
NASA Astrophysics Data System (ADS)
Watanabe, Hiroshi; Araki, Noriyuki; Fujimoto, Hisashi
Broadband optical access services are spreading throughout the world, and the number of fiber to the home (FTTH) subscribers is increasing rapidly. Telecom operators are constructing passive optical networks (PONs) to provide optical access services. Externally installed optical splitters for PONs are very important passive devices in optical access networks, and they must provide satisfactory performance as outdoor plant over long periods. Therefore, we calculate the failure rate of optical access networks and assign a failure rate to the optical splitters in optical access networks. The maximum cumulative failure rate of 1 × 8 optical splitters was calculated as 0.025 for an optical access fiber length of 2.1km and a 20-year operating lifetime. We examined planar lightwave circuit (PLC) type optical splitters for use as outside plant in terms of their optical characteristics and environmental reliability. We confirmed that PLC type optical splitters have sufficient optical performance for a PON splitter and sufficient reliability as outside plant in accordance with ITU-T standard values. We estimated the lifetimes of three kinds of PLC type optical splitters by using accelerated aging tests. The estimated failure rate of these splitters installed in optical access networks was below the target value for the cumulative failure rate, and we confirmed that they have sufficient reliability to maintain the quality of the network service. We developed 1 × 8 optical splitter modules with plug and socket type optical connectors and optical fiber cords for optical aerial closures designed for use as outside plant. These technologies make it easy to install optical splitters in an aerial optical closure. The optical splitter modules have sufficient optical performance levels for PONs because the insertion loss at the commercially used wavelengths of 1.31 and 1.55µm is less than the criterion established by ITU-T Recommendation G.671 for optical splitters. We performed a temperature cycling test, and a low temperature storage and damp heat test to confirm the long-term reliability of these modules. They exhibited sufficient reliability as regards heat and moisture because the maximum loss change was less than 0.3dB.
Properties of Perfluoropolyethers for Space Applications
NASA Technical Reports Server (NTRS)
Jones, William R., Jr.
1994-01-01
The perfluoropolyether (PFPE) class of liquid lubricants has been used for space applications for over two decades. At first, these fluids performed satisfactorily as early spacecraft placed few demands on their performance. However, as other spacecraft components have become more reliable and lifetimes have been extended, PFPE lubricant deficiencies have been exposed. Therefore, the objective of this paper is to review the PFPE properties that are important for successful long term operation in space.
Environment assisted degradation mechanisms in advanced light metals
NASA Technical Reports Server (NTRS)
Gangloff, R. P.; Stoner, G. E.; Swanson, R. E.
1989-01-01
A multifaceted research program on the performance of advanced light metallic alloys in aggressive aerospace environments, and associated environmental failure mechanisms was initiated. The general goal is to characterize alloy behavior quantitatively and to develop predictive mechanisms for environmental failure modes. Successes in this regard will provide the basis for metallurgical optimization of alloy performance, for chemical control of aggressive environments, and for engineering life prediction with damage tolerance and long term reliability.
The properties of perfluoropolyethers used for space applications
NASA Technical Reports Server (NTRS)
Jones, William R., Jr.
1993-01-01
The perfluoropolyether (PFPE) class of liquid lubricants has been used for space applications for over two decades. At first, these fluids performed satisfactorily as early spacecraft placed few demands on their performance. However, as other spacecraft components have become more reliable and lifetimes have been extended, PFPE lubricant deficiencies have been exposed. Therefore, the objective of this paper is to review the PFPE properties that are important for successful long term operation in space.
Monitoring of formaldehyde in air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balmat, J.L.; Meadows, G.W.
1985-10-01
Any one of several monitoring methods, depending on requirement and circumstance, can be used to measure employee exposure to formaldehyde. Ordinarily, monitoring at DuPont is performed by sampling with impingers containing 1% aqueous sodium bisulfite or with silica gel tubes. The collected formaldehyde is measured spectrophotometrically after reaction with chromotropic acid. Results from studies on a selected number of formaldehyde monitoring methods reveal that reliable methods are available for area and personnel monitoring over both short term and long term. Accurate results are obtained from short-term monitoring (15 min at 1 L/min) with impingers of formaldehyde concentrations as low asmore » 0.14 ppm. The current studies show that long-term monitoring (8 hr at 0.5 L/min) can be performed accurately at concentrations as low as 0.05 ppm. Accurate results also are obtained from short-term monitoring (15 min at 500 mL/min) with silica gel tubes of concentrations as low as 0.11 ppm formaldehyde. Passive monitors provide the most convenient means of obtaining 8-hour time-weighted average (TWA) data. The Pro-Tek Formaldehyde Badge was demonstrated to reliably monitor formaldehyde concentrations varying from 0-0.5 ppm or 0-3 ppm. Investigation of the Lion Formaldemeter disclosed that instantaneous and accurate (+/- 5%) measurement of formaldehyde in air can be made over a concentration range of 0.3-5 ppm in the absence of other substances that are oxidizable in its fuel cell detector.« less
Ultracompliant Heterogeneous Copper-Tin Nanowire Arrays Making a Supersolder
DOE Office of Scientific and Technical Information (OSTI.GOV)
Narumanchi, Sreekant V; Feng, Xuhui; Major, Joshua
Due to the substantial increase in power density, thermal interface resistance that can constitute more than 50% of the total thermal resistance has generally become a bottleneck for thermal management in electronics. However, conventional thermal interface materials (TIMs) such as solder, epoxy, gel, and grease cannot fulfill the requirements of electronics for high-power and long-term operation. Here, we demonstrate a high-performance TIM consisting of a heterogeneous copper-tin nanowire array, which we term 'supersolder' to emulate the role of conventional solders in bonding various surfaces. The supersolder is ultracompliant with a shear modulus 2-3 orders of magnitude lower than traditional soldersmore » and can reduce the thermal resistance by two times as compared with the state-of-the-art TIMs. This supersolder also exhibits excellent long-term reliability with >1200 thermal cycles over a wide temperature range. By resolving this critical thermal bottleneck, the supersolder enables electronic systems, ranging from microelectronics and portable electronics to massive data centers, to operate at lower temperatures with higher power density and reliability.« less
Study of cyclic thermal aging of tube type receivers as a function of the duration of the cycle
NASA Astrophysics Data System (ADS)
Setien, Eneko; Fernández-Reche, Jesús; Ariza, María Jesús; Álvarez-de-Lara, Mónica
2017-06-01
The tube type receivers are exposed to variable duration cyclic operating conditions, which can jeopardize its reliability, and make it hard to estimate its long term performance. The designers have to deal with this problem and estimate the receiver long term performance based on the poor available litterature and the data sheets of the material. In order to help the designer better estimate the performance of the receivers, in this paper the cyclic thermal aging is analyzed as a function of the cycle duration. For this purpose, coated and uncoated Inconel alloy 625 tubular samples, similar to those used in the commercial receivers, are cyclically aged with different thermal cycle duration. The aging of these samples has been analyzed by means of oxidation kinetics, microstructure examination and mechanical and optical properties. The effect of the thermal cycle duration is studied and discussed by comparison of the results.
Evaluating Internal Model Strength and Performance of Myoelectric Prosthesis Control Strategies.
Shehata, Ahmed W; Scheme, Erik J; Sensinger, Jonathon W
2018-05-01
On-going developments in myoelectric prosthesis control have provided prosthesis users with an assortment of control strategies that vary in reliability and performance. Many studies have focused on improving performance by providing feedback to the user but have overlooked the effect of this feedback on internal model development, which is key to improve long-term performance. In this paper, the strength of internal models developed for two commonly used myoelectric control strategies: raw control with raw feedback (using a regression-based approach) and filtered control with filtered feedback (using a classifier-based approach), were evaluated using two psychometric measures: trial-by-trial adaptation and just-noticeable difference. The performance of both strategies was also evaluated using Schmidt's style target acquisition task. Results obtained from 24 able-bodied subjects showed that although filtered control with filtered feedback had better short-term performance in path efficiency ( ), raw control with raw feedback resulted in stronger internal model development ( ), which may lead to better long-term performance. Despite inherent noise in the control signals of the regression controller, these findings suggest that rich feedback associated with regression control may be used to improve human understanding of the myoelectric control system.
Soil respiration is not limited by reductions in microbial biomass during long-term soil incubations
USDA-ARS?s Scientific Manuscript database
Declining rates of soil respiration are reliably observed during long-term laboratory incubations, but the cause is uncertain. We explored different controls on soil respiration during long-term soil incubations. Following a 707 day incubation (30 C) of soils from cultivated and forested plots at Ke...
Vivas, Esther X; Carlson, Matthew L; Neff, Brian A; Shepard, Neil T; McCracken, D Jay; Sweeney, Alex D; Olson, Jeffrey J
2018-02-01
Does intraoperative facial nerve monitoring during vestibular schwannoma surgery lead to better long-term facial nerve function? This recommendation applies to adult patients undergoing vestibular schwannoma surgery regardless of tumor characteristics. Level 3: It is recommended that intraoperative facial nerve monitoring be routinely utilized during vestibular schwannoma surgery to improve long-term facial nerve function. Can intraoperative facial nerve monitoring be used to accurately predict favorable long-term facial nerve function after vestibular schwannoma surgery? This recommendation applies to adult patients undergoing vestibular schwannoma surgery. Level 3: Intraoperative facial nerve can be used to accurately predict favorable long-term facial nerve function after vestibular schwannoma surgery. Specifically, the presence of favorable testing reliably portends a good long-term facial nerve outcome. However, the absence of favorable testing in the setting of an anatomically intact facial nerve does not reliably predict poor long-term function and therefore cannot be used to direct decision-making regarding the need for early reinnervation procedures. Does an anatomically intact facial nerve with poor electromyogram (EMG) electrical responses during intraoperative testing reliably predict poor long-term facial nerve function? This recommendation applies to adult patients undergoing vestibular schwannoma surgery. Level 3: Poor intraoperative EMG electrical response of the facial nerve should not be used as a reliable predictor of poor long-term facial nerve function. Should intraoperative eighth cranial nerve monitoring be used during vestibular schwannoma surgery? This recommendation applies to adult patients undergoing vestibular schwannoma surgery with measurable preoperative hearing levels and tumors smaller than 1.5 cm. Level 3: Intraoperative eighth cranial nerve monitoring should be used during vestibular schwannoma surgery when hearing preservation is attempted. Is direct monitoring of the eighth cranial nerve superior to the use of far-field auditory brain stem responses? This recommendation applies to adult patients undergoing vestibular schwannoma surgery with measurable preoperative hearing levels and tumors smaller than 1.5 cm. Level 3: There is insufficient evidence to make a definitive recommendation. The full guideline can be found at: https://www.cns.org/guidelines/guidelines-manage-ment-patients-vestibular-schwannoma/chapter_4. Copyright © 2017 by the Congress of Neurological Surgeons
The long-term reliability of static and dynamic quantitative sensory testing in healthy individuals.
Marcuzzi, Anna; Wrigley, Paul J; Dean, Catherine M; Adams, Roger; Hush, Julia M
2017-07-01
Quantitative sensory tests (QSTs) have been increasingly used to investigate alterations in somatosensory function in a wide range of painful conditions. The interpretation of these findings is based on the assumption that the measures are stable and reproducible. To date, reliability of QST has been investigated for short test-retest intervals. The aim of this study was to investigate the long-term reliability of a multimodal QST assessment in healthy people, with testing conducted on 3 occasions over 4 months. Forty-two healthy people were enrolled in the study. Static and dynamic tests were performed, including cold and heat pain threshold (CPT, HPT), mechanical wind-up [wind-up ratio (WUR)], pressure pain threshold (PPT), 2-point discrimination (TPD), and conditioned pain modulation (CPM). Systematic bias, relative reliability and agreement were analysed using repeated measure analysis of variance, intraclass correlation coefficients (ICCs3,1) and SE of the measurement (SEM), respectively. Static QST (CPT, HPT, PPT, and TPD) showed good-to-excellent reliability (ICCs: 0.68-0.90). Dynamic QST (WUR and CPM) showed poor-to-good reliability (ICCs: 0.35-0.61). A significant linear decrease over time was observed for mechanical QST at the back (PPT and TPD) and for CPM (P < 0.01). Static QST were stable over a period of 4 months; however, a small systematic decrease over time has been observed for mechanical QST. Dynamic QST showed considerable variability over time; in particular, CPM using PPT as the test stimulus did not show adequate reliability, suggesting that this test paradigm may be less useful for monitoring individuals over time.
Long-Term Reliability of a Hard-Switched Boost Power Processing Unit Utilizing SiC Power MOSFETs
NASA Technical Reports Server (NTRS)
Ikpe, Stanley A.; Lauenstein, Jean-Marie; Carr, Gregory A.; Hunter, Don; Ludwig, Lawrence L.; Wood, William; Iannello, Christopher J.; Del Castillo, Linda Y.; Fitzpatrick, Fred D.; Mojarradi, Mohammad M.;
2016-01-01
Silicon carbide (SiC) power devices have demonstrated many performance advantages over their silicon (Si) counterparts. As the inherent material limitations of Si devices are being swiftly realized, wide-band-gap (WBG) materials such as SiC have become increasingly attractive for high power applications. In particular, SiC power metal oxide semiconductor field effect transistors' (MOSFETs) high breakdown field tolerance, superior thermal conductivity and low-resistivity drift regions make these devices an excellent candidate for power dense, low loss, high frequency switching applications in extreme environment conditions. In this paper, a novel power processing unit (PPU) architecture is proposed utilizing commercially available 4H-SiC power MOSFETs from CREE Inc. A multiphase straight boost converter topology is implemented to supply up to 10 kilowatts full-scale. High Temperature Gate Bias (HTGB) and High Temperature Reverse Bias (HTRB) characterization is performed to evaluate the long-term reliability of both the gate oxide and the body diode of the SiC components. Finally, susceptibility of the CREE SiC MOSFETs to damaging effects from heavy-ion radiation representative of the on-orbit galactic cosmic ray environment are explored. The results provide the baseline performance metrics of operation as well as demonstrate the feasibility of a hard-switched PPU in harsh environments.
Probabilistic resource allocation system with self-adaptive capability
NASA Technical Reports Server (NTRS)
Yufik, Yan M. (Inventor)
1998-01-01
A probabilistic resource allocation system is disclosed containing a low capacity computational module (Short Term Memory or STM) and a self-organizing associative network (Long Term Memory or LTM) where nodes represent elementary resources, terminal end nodes represent goals, and weighted links represent the order of resource association in different allocation episodes. Goals and their priorities are indicated by the user, and allocation decisions are made in the STM, while candidate associations of resources are supplied by the LTM based on the association strength (reliability). Weights are automatically assigned to the network links based on the frequency and relative success of exercising those links in the previous allocation decisions. Accumulation of allocation history in the form of an associative network in the LTM reduces computational demands on subsequent allocations. For this purpose, the network automatically partitions itself into strongly associated high reliability packets, allowing fast approximate computation and display of allocation solutions satisfying the overall reliability and other user-imposed constraints. System performance improves in time due to modification of network parameters and partitioning criteria based on the performance feedback.
A simple method for long-term biliary access in large animals.
Andrews, J C; Knutsen, C; Smith, P; Prieskorn, D; Crudip, J; Klevering, J; Ensminger, W D
1988-07-01
A simple method to obtain long-term access to the biliary tree in dogs and pigs is presented. In ten dogs and four pigs, a cholecystectomy was performed, the cystic duct isolated, and a catheter inserted into the cut end of the cystic duct. The catheter was connected to a subcutaneous infusion port, producing a closed, internal system to allow long-term access. The catheter placement was successful in three of the pigs and all of the dogs. Thirty-five cholangiograms were obtained in the 13 subjects by accessing the port with a 20 gauge Huber needle and injecting small amounts (4-10 mL) of contrast under fluoroscopic control. Cholangiograms were obtained up to four months after catheter placement without evidence for catheter failure or surgically induced changes in the biliary tree. This model provides a simple, reliable means to obtain serial cholangiograms in a research setting.
Using Hybrid Magnetic Bearings to Completely Suspend the Impeller of a Ventricular Assist Device.
Khanwilkar, Pratap; Olsen, Don; Bearnson, Gill; Allaire, Paul; Maslen, Eric; Flack, Ron; Long, James
1996-05-01
Clinically available blood pumps and those under development suffer from poor mechanical reliability and poor biocompatibility related to anatomic fit, hemolysis, and thrombosis. To alleviate these problems concurrently in a long-term device is a substantial challenge. Based on testing the performance of a prototype, and on our judgment of desired characteristics, we have configured an innovative ventricular assist device, the CF-VAD4, for long-term use. The design process and its outcome, the CFVAD4 system configuration, is described. To provide unprecedented reliability and biocompatibility, magnetic bearings completely suspend the rotating pump impeller. The CFVAD4 uses a combination of passive (permanent) and active (electric) magnetic bearings, a mixed flow impeller, and a slotless 3-phase brushless DC motor. These components are shaped, oriented, and integrated to provide a compact, implantable, pancake-shaped unit for placement in the left upper abdominal quadrant of adult humans. © 1996 International Society for Artificial Organs.
ERIC Educational Resources Information Center
Achilles, C. M.; Krieger, Jean D.; Finn, J. D.; Sharp, Mark
Small classes in grades K-3 boost student academic performance in all subjects and in prosocial behavior. Results are both short- and long-term. One study explored the theory that a major cause behind improved academic achievement involves improved student behavior, which increases student engagement in the classroom. Two other studies provide…
Predicting photoyellowing behaviour of mechanical pulp containing papers
Umesh P. Agarwal
2005-01-01
It is well known that paper produced from mechanical-pulp-containing fiber furnish yellows upon exposure to light. Although the accelerated light-aging test method has been used to compare papers and predict long term performance, the reliability of the light-aging method has been questioned. Therefore, a method that can correctly predict a paperâs light stability is...
An Overview of Long Duration Sodium Heat Pipe Tests
NASA Astrophysics Data System (ADS)
Rosenfeld, John H.; Ernst, Donald M.; Lindemuth, James E.; Sanzi, James L.; Geng, Steven M.; Zuo, Jon
2004-02-01
High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore, Inc. has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 316L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650C to 700C for over 115,000 hours without signs of failure. A second 316L stainless steel heat pipe with a specially-designed Inconel 601 rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600C to 650C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41,000 hours at nearly 700C. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed.
An Overview of Long Duration Sodium Heat Pipe Tests
NASA Technical Reports Server (NTRS)
Rosenfeld, John H.; Ernst, Donald M.; Lindemuth, James E.; Sanzi, James L.; Geng, Steven M.; Zuo, Jon
2004-01-01
High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore International, Inc., has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 3l6L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650 to 700 C for over 115,000 hours without signs of failure. A second 3l6L stainless steel heat pipe with a specially-designed Inconel 60 I rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600 to 650 C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41 ,000 hours at nearly 700 0c. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700 C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability, Detailed design specifications, operating hi story, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed.
NASA Astrophysics Data System (ADS)
Marques, G.; Fraga, C. C. S.; Medellin-Azuara, J.
2016-12-01
The expansion and operation of urban water supply systems under growing demands, hydrologic uncertainty and water scarcity requires a strategic combination of supply sources for reliability, reduced costs and improved operational flexibility. The design and operation of such portfolio of water supply sources involves integration of long and short term planning to determine what and when to expand, and how much to use of each supply source accounting for interest rates, economies of scale and hydrologic variability. This research presents an integrated methodology coupling dynamic programming optimization with quadratic programming to optimize the expansion (long term) and operations (short term) of multiple water supply alternatives. Lagrange Multipliers produced by the short-term model provide a signal about the marginal opportunity cost of expansion to the long-term model, in an iterative procedure. A simulation model hosts the water supply infrastructure and hydrologic conditions. Results allow (a) identification of trade offs between cost and reliability of different expansion paths and water use decisions; (b) evaluation of water transfers between urban supply systems; and (c) evaluation of potential gains by reducing water system losses as a portfolio component. The latter is critical in several developing countries where water supply system losses are high and often neglected in favor of more system expansion.
Characterization of the NEXT Hollow Cathode Inserts After Long-Duration Testing
NASA Technical Reports Server (NTRS)
Mackey, J.; Shastry, R.; Soulas, G.
2017-01-01
Hollow dispenser cathode inserts are a critical element of electric propulsion systems, and should therefore be well understood during long term operation to ensure reliable system performance. This work destructively investigated cathode inserts from the NEXT long-duration test which demonstrated 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The characterization methods used include scanning electron microscopy with energy dispersive spectroscopy and X-ray diffraction. Microscopy analysis has been performed on fractured surfaces, emission surfaces, and metallographically polished cross-sections of post-test inserts and unused inserts. Impregnate distribution, etch region thickness, impregnate chemical content, emission surface topography, and emission surface phase identification are the primary factors investigated.
Silicon Nanophotonics for Many-Core On-Chip Networks
NASA Astrophysics Data System (ADS)
Mohamed, Moustafa
Number of cores in many-core architectures are scaling to unprecedented levels requiring ever increasing communication capacity. Traditionally, architects follow the path of higher throughput at the expense of latency. This trend has evolved into being problematic for performance in many-core architectures. Moreover, the trends of power consumption is increasing with system scaling mandating nontraditional solutions. Nanophotonics can address these problems, offering benefits in the three frontiers of many-core processor design: Latency, bandwidth, and power. Nanophotonics leverage circuit-switching flow control allowing low latency; in addition, the power consumption of optical links is significantly lower compared to their electrical counterparts at intermediate and long links. Finally, through wave division multiplexing, we can keep the high bandwidth trends without sacrificing the throughput. This thesis focuses on realizing nanophotonics for communication in many-core architectures at different design levels considering reliability challenges that our fabrication and measurements reveal. First, we study how to design on-chip networks for low latency, low power, and high bandwidth by exploiting the full potential of nanophotonics. The design process considers device level limitations and capabilities on one hand, and system level demands in terms of power and performance on the other hand. The design involves the choice of devices, designing the optical link, the topology, the arbitration technique, and the routing mechanism. Next, we address the problem of reliability in on-chip networks. Reliability not only degrades performance but can block communication. Hence, we propose a reliability-aware design flow and present a reliability management technique based on this flow to address reliability in the system. In the proposed flow reliability is modeled and analyzed for at the device, architecture, and system level. Our reliability management technique is superior to existing solutions in terms of power and performance. In fact, our solution can scale to thousand core with low overhead.
Moore, Amy Lawson; Miller, Terissa M
2018-01-01
The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agalgaonkar, Yashodhan P.; Hammerstrom, Donald J.
The Pacific Northwest Smart Grid Demonstration (PNWSGD) was a smart grid technology performance evaluation project that included multiple U.S. states and cooperation from multiple electric utilities in the northwest region. One of the local objectives for the project was to achieve improved distribution system reliability. Toward this end, some PNWSGD utilities automated their distribution systems, including the application of fault detection, isolation, and restoration and advanced metering infrastructure. In light of this investment, a major challenge was to establish a correlation between implementation of these smart grid technologies and actual improvements of distribution system reliability. This paper proposes using Welch’smore » t-test to objectively determine and quantify whether distribution system reliability is improving over time. The proposed methodology is generic, and it can be implemented by any utility after calculation of the standard reliability indices. The effectiveness of the proposed hypothesis testing approach is demonstrated through comprehensive practical results. It is believed that wider adoption of the proposed approach can help utilities to evaluate a realistic long-term performance of smart grid technologies.« less
NASA Astrophysics Data System (ADS)
Sin, Yongkun; Presser, Nathan; Brodie, Miles; Lingley, Zachary; Foran, Brendan; Moss, Steven C.
2015-03-01
Laser diode manufacturers perform accelerated multi-cell lifetests to estimate lifetimes of lasers using an empirical model. Since state-of-the-art laser diodes typically require a long period of latency before they degrade, significant amount of stress is applied to the lasers to generate failures in relatively short test durations. A drawback of this approach is the lack of mean-time-to-failure data under intermediate and low stress conditions, leading to uncertainty in model parameters (especially optical power and current exponent) and potential overestimation of lifetimes at usage conditions. This approach is a concern especially for satellite communication systems where high reliability is required of lasers for long-term duration in the space environment. A number of groups have studied reliability and degradation processes in GaAs-based lasers, but none of these studies have yielded a reliability model based on the physics of failure. The lack of such a model is also a concern for space applications where complete understanding of degradation mechanisms is necessary. Our present study addresses the aforementioned issues by performing long-term lifetests under low stress conditions followed by failure mode analysis (FMA) and physics of failure investigation. We performed low-stress lifetests on both MBE- and MOCVD-grown broad-area InGaAs- AlGaAs strained QW lasers under ACC (automatic current control) mode to study low-stress degradation mechanisms. Our lifetests have accumulated over 36,000 test hours and FMA is performed on failures using our angle polishing technique followed by EL. This technique allows us to identify failure types by observing dark line defects through a window introduced in backside metal contacts. We also investigated degradation mechanisms in MOCVD-grown broad-area InGaAs-AlGaAs strained QW lasers using various FMA techniques. Since it is a challenge to control defect densities during the growth of laser structures, we chose to control defect densities by introducing extrinsic point defects to the laser via proton irradiation with different energies and fluences. These lasers were subsequently lifetested to study degradation processes in the lasers with different defect densities and also to study precursor signatures of failures - traps and non-radiative recombination centers (NRCs) in pre- and post-stressed lasers. Lastly, we employed focused ion beam (FIB), electron beam induced current (EBIC), and highresolution TEM (HR-TEM) techniques to further study dark line defects and dislocations in both post-aged and postproton irradiated lasers. We report on our long-term low-stress lifetest results and physics of failure investigation results.
Accelerated life testing effects on CMOS microcircuit characteristics
NASA Technical Reports Server (NTRS)
1977-01-01
Accelerated life tests were performed on CMOS microcircuits to predict their long term reliability. The consistency of the CMOS microcircuit activation energy between the range of 125 C to 200 C and the range 200 C to 250 C was determined. Results indicate CMOS complexity and the amount of moisture detected inside the devices after testing influences time to failure of tested CMOS devices.
Development of the NASA/Baylor VAD
NASA Technical Reports Server (NTRS)
Aber, G. S.; Akkerman, J. W.; Bozeman, R. J., Jr.; Saucler, D. R.; Bacak, J. W.; Svejkovsky, P. A.; Damm, G. A.; Mizuguchi, K.; Noon, G. P.; Nose, Y.
1994-01-01
A cooperative effort between the NASA/Johnson Space Center (JSC) and the Baylor College of Medicine (BCM) has been underway since 1988 to develop a long-term implantable Ventricular Assist Device (VAD). The VAD is intended to boost the cardiac output of patients with deteriorated cardiac function. For many of these patients, the best alternative is heart transplantation. Heart transplantation is a complex and expensive procedure and usually requires a long waiting period for a donor heart. The condition of the patient often deteriorates during this waiting period which complicates the pre and post-operative care. Because of these factors, the need for a long-term implantable VAD for use as a bridge-to-transplant device or as a permanent assist device has become the focus of much research. The need for a VAD has been estimated at 50,000 to 60,000 patients per year in the United States alone. A device which satisfies all the system performance and reliability requirements has yet to be achieved. However, the development of the NASA/Baylor VAD has progressed to a state in which commercial viability can being to be considered. The device is small, simple, efficient and reliable which meets all requirements for a totally implantable VAD.
In Situ, On-Demand Lubrication System Developed for Space Mechanisms
NASA Technical Reports Server (NTRS)
Marchetti, Mario; Pepper, Stephen V.; Jansen, Mark J.; Predmore, Roamer E.
2003-01-01
Many moving mechanical assemblies (MMA) for space mechanisms rely on liquid lubricants to provide reliable, long-term performance. The proper performance of the MMA is critical in assuring a successful mission. Historically, mission lifetimes were short and MMA duty cycles were minimal. As mission lifetimes were extended, other components, such as batteries and computers, failed before lubricated systems. However, improvements in these ancillary systems over the last decade have left the tribological systems of the MMAs as the limiting factor in determining spacecraft reliability. Typically, MMAs are initially lubricated with a very small charge that is supposed to last the entire mission lifetime, often well in excess of 5 years. In many cases, the premature failure of a lubricated component can result in mission failure.
Effects of extended lay-off periods on performance and operator trust under adaptable automation.
Chavaillaz, Alain; Wastell, David; Sauer, Jürgen
2016-03-01
Little is known about the long-term effects of system reliability when operators do not use a system during an extended lay-off period. To examine threats to skill maintenance, 28 participants operated twice a simulation of a complex process control system for 2.5 h, with an 8-month retention interval between sessions. Operators were provided with an adaptable support system, which operated at one of the following reliability levels: 60%, 80% or 100%. Results showed that performance, workload, and trust remained stable at the second testing session, but operators lost self-confidence in their system management abilities. Finally, the effects of system reliability observed at the first testing session were largely found again at the second session. The findings overall suggest that adaptable automation may be a promising means to support operators in maintaining their performance at the second testing session. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Comparison of Models of Stress Relaxation in Failure Analysis for Connectors under Long-term Storage
NASA Astrophysics Data System (ADS)
Zhou, Yilin; Wan, Mengru
2018-03-01
Reliability requirements of the system equipment under long-term storage are put forward especially for the military products, so that the connectors in the equipment also need long-term storage life correspondingly. In this paper, the effects of stress relaxation of the elastic components on electrical contact of the connectors in long-term storage process were studied from the failure mechanism and degradation models. A wire spring connector was taken as an example to discuss the life prediction method for electrical contacts of the connectors based on stress relaxation degradation under long -term storage.
NASA Astrophysics Data System (ADS)
Saito, Kotaro; Kihara, Mitsuru; Shimizu, Tomoya; Yoneda, Keisuke; Kurashima, Toshio
2015-06-01
We performed environmental and accelerated aging tests to ensure the long-term reliability of solid type refractive index matching material at a splice point. Stable optical characteristics were confirmed in environmental tests based on an IEC standard. In an accelerated aging test at 140 °C, which is very much higher than the specification test temperature, the index matching material itself and spliced fibers passing through it had steady optical characteristics. Then we performed an accelerated aging test on an index matching material attached to a built-in fiber before splicing it in the worst condition, which is different from the normal use configuration. As a result, we confirmed that the repeated insertion and removal of fiber for splicing resulted in failure. We consider that the repetition of adhesion between index matching material and fibers causes the splice to degrade. With this result, we used the Arrhenius model to estimate a median lifetime of about 68 years in a high temperature environment of 60 °C. Thus solid type index matching material at a splice point is highly reliable over long periods under normal conditions of use.
Olszewska, Justyna M; Reuter-Lorenz, Patricia A; Munier, Emily; Bendler, Sara A
2015-09-01
False working memories readily emerge using a visual item-recognition variant of the converging associates task. Two experiments, manipulating study and test modality, extended prior working memory results by demonstrating a reliable false recognition effect (more false alarms to associatively related lures than to unrelated lures) within seconds of encoding in either the visual or auditory modality. However, false memories were nearly twice as frequent when study lists were seen than when they were heard, regardless of test modality, although study-test modality mismatch was generally disadvantageous (consistent with encoding specificity). A final experiment that varied study-test modality using a hybrid short- and long-term memory test (Flegal, Atkins & Reuter-Lorenz, 2010) replicated the auditory advantage in the short term but revealed a reversal in the long term: The false memory effect was greater in the auditory study-test condition than in the visual study-test condition. Thus, the same encoding conditions gave rise to an opposite modality advantage depending on whether recognition was tested under short-term or long-term memory conditions. Although demonstrating continuity in associative processing across delay, the results indicate that delay condition affects the availability of modality-dependent features of the memory trace and, thus, distinctiveness, leading to dissociable patterns of short- and long-term memory performance. (c) 2015 APA, all rights reserved).
A Novel Nipple Reconstruction Technique for Maintaining Nipple Projection: The Boomerang Flap
Kim, Young-Eun; Hong, Ki Yong; Minn, Kyung Won
2016-01-01
Nipple-areolar complex (NAC) reconstruction is the final step in the long journey of breast reconstruction for mastectomy patients. Successful NAC reconstruction depends on the use of appropriate surgical techniques that are simple and reliable. To date, numerous techniques have been used for nipple reconstruction, including contralateral nipple sharing and various local flaps. Recently, it has been common to utilize local flaps. However, the most common nipple reconstruction problem encountered with local flaps is the loss of nipple projection; there can be approximately 50% projection loss in reconstructed nipples over long-term follow-up. Several factors might contribute to nipple projection loss, and we tried to overcome these factors by performing nipple reconstructions using a boomerang flap technique, which is a modified C–V flap that utilizes the previous mastectomy scar to maintain long-term nipple projection. PMID:27689057
A Novel Nipple Reconstruction Technique for Maintaining Nipple Projection: The Boomerang Flap.
Kim, Young-Eun; Hong, Ki Yong; Minn, Kyung Won; Jin, Ung Sik
2016-09-01
Nipple-areolar complex (NAC) reconstruction is the final step in the long journey of breast reconstruction for mastectomy patients. Successful NAC reconstruction depends on the use of appropriate surgical techniques that are simple and reliable. To date, numerous techniques have been used for nipple reconstruction, including contralateral nipple sharing and various local flaps. Recently, it has been common to utilize local flaps. However, the most common nipple reconstruction problem encountered with local flaps is the loss of nipple projection; there can be approximately 50% projection loss in reconstructed nipples over long-term follow-up. Several factors might contribute to nipple projection loss, and we tried to overcome these factors by performing nipple reconstructions using a boomerang flap technique, which is a modified C-V flap that utilizes the previous mastectomy scar to maintain long-term nipple projection.
Cryogenic Fluid Management Technologies for Advanced Green Propulsion Systems
NASA Technical Reports Server (NTRS)
Motil, Susan M.; Meyer, Michael L.; Tucker, Stephen P.
2007-01-01
In support of the Exploration Vision for returning to the Moon and beyond, NASA and its partners are developing and testing critical cryogenic fluid propellant technologies that will meet the need for high performance propellants on long-term missions. Reliable knowledge of low-gravity cryogenic fluid management behavior is lacking and yet is critical in the areas of tank thermal and pressure control, fluid acquisition, mass gauging, and fluid transfer. Such knowledge can significantly reduce or even eliminate tank fluid boil-off losses for long term missions, reduce propellant launch mass and required on-orbit margins, and simplify vehicle operations. The Propulsion and Cryogenic Advanced Development (PCAD) Project is performing experimental and analytical evaluation of several areas within Cryogenic Fluid Management (CFM) to enable NASA's Exploration Vision. This paper discusses the status of the PCAD CFM technology focus areas relative to the anticipated CFM requirements to enable execution of the Vision for Space Exploration.
Lee, James
2009-01-01
The Long-Term Mechanical Circulatory Support (MCS) System Reliability Recommendation was published in the American Society for Artificial Internal Organs (ASAIO) Journal and the Annals of Thoracic Surgery in 1998. At that time, it was stated that the document would be periodically reviewed to assess its timeliness and appropriateness within 5 years. Given the wealth of clinical experience in MCS systems, a new recommendation has been drafted by consensus of a group of representatives from the medical community, academia, industry, and government. The new recommendation describes a reliability test methodology and provides detailed reliability recommendations. In addition, the new recommendation provides additional information and clinical data in appendices that are intended to assist the reliability test engineer in the development of a reliability test that is expected to give improved predictions of clinical reliability compared with past test methods. The appendices are available for download at the ASAIO journal web site at www.asaiojournal.com.
Government and industry interactions in the development of clock technology
NASA Technical Reports Server (NTRS)
Hellwig, H.
1981-01-01
It appears likely that everyone in the time and frequency community can agree on goals to be realized through the expenditure of resources. These goals are the same as found in most fields of technology: lower cost, better performance, increased reliability, small size and lower power. Related aspects are examined in the process of clock and frequency standard development. Government and industry are reviewed in a highly interactive role. These interactions include judgements on clock performance, what kind of clock, expenditure of resources, transfer of ideas or hardware concepts from government to industry, and control of production. Successful clock development and production requires a government/industry relationship which is characterized by long-term continuity, multidisciplinary team work, focused funding and a separation of reliability and production oriented tasks from performance improvement/research type efforts.
The Effect of Technical Performance on Patient Outcomes in Surgery: A Systematic Review.
Fecso, Andras B; Szasz, Peter; Kerezov, Georgi; Grantcharov, Teodor P
2017-03-01
Systematic review of the effect of intraoperative technical performance on patient outcomes. The operating room is a high-stakes, high-risk environment. As a result, the quality of surgical interventions affecting patient outcomes has been the subject of discussion and research for years. MEDLINE, EMBASE, PsycINFO, and Cochrane databases were searched. All surgical specialties were eligible for inclusion. Data were reviewed in regards to the methods by which technical performance was measured, what patient outcomes were assessed, and how intraoperative technical performance affected patient outcomes. Quality of evidence was assessed using the Medical Education Research Study Quality Instrument (MERSQI). Of the 12,758 studies initially identified, 24 articles (7775 total participants) were ultimately included in this review. Seventeen studies assessed the performance of the faculty alone, 2 assessed both the faculty and trainees, 1 assessed trainees alone, and in 4 studies, the level of the operating surgeon was not specified. In 18 studies, a performance assessment tool was used. Patient outcomes were evaluated using intraoperative complications, short-term morbidity, long-term morbidity, short-term mortality, and long-term mortality. The average MERSQI score was 11.67 (range 9.5-14.5). Twenty-one studies demonstrated that superior technical performance was related to improved patient outcomes. The results of this systematic review demonstrated that superior technical performance positively affects patient outcomes. Despite this initial evidence, more robust research is needed to directly assess intraoperative technical performance and its effect on postoperative patient outcomes using meaningful assessment instruments and reliable processes.
Reliability of the penetration aspiration scale with flexible endoscopic evaluation of swallowing.
Butler, Susan G; Markley, Lisa; Sanders, Brian; Stuart, Andrew
2015-06-01
The Penetration Aspiration Scale (PAS), although designed for videofluoroscopy, has been utilized with flexible endoscopic evaluation of swallowing (FEES) in both research and clinical practice. The purpose of this investigation was to determine inter- and intrarater reliability of the PAS with FEES as a function of clinician FEES experience and retest interval. Three groups of 3 clinicians (N=9) with varying FEES experience (beginning, intermediate, and advanced) assigned PAS scores to 35 swallows. Initial ratings were repeated following short-term (ie, 1 day) and long-term (ie, 1 week) retest intervals. Intraclass correlation coefficients were calculated to assess interrater reliability on the first rating for each group. The coefficients were .91, .82, and .89 for the beginning, intermediate, and advanced clinicians, respectively. Overall interrater reliability across all 9 clinicians, irrespective of experience, was .85. Intraclass correlation coefficients were also calculated to assess intrarater reliability. The intrarater reliability for short- and long-term ratings was .90, .94, and .96 and .96, .97, and .94 for the beginning, intermediate, and advanced clinicians, respectively. Overall intrarater reliability across all 9 clinicians and all 3 ratings was .94. Excellent inter- and intrarater reliability was evidenced with the application of the PAS for FEES regardless of clinician experience and retest interval. © The Author(s) 2015.
Development and psychometric evaluation of supportive leadership scales.
McGilton, Katherine S
2003-12-01
The purpose of this study was to develop and evaluate the psychometric properties of 2 supportive leadership scales, the Charge Nurse Support Scale and the Unit Manager Support Scale, designed for long-term-care environments. These 6-item self-report scales were administered to 70 nursing staff and their internal consistency reliability, test-retest reliability, content validity, factor structure, and construct validity investigated. Content validity was established with the assistance of experts. Both scales were deemed reliable. As hypothesized, a significant relationship was found between the measure of how nursing staff related to residents and measures of charge nurses' supportive behaviours (r = .42, p = .05). Reliable and valid measures of supportive leadership could be developed for use in identifying the quality of support provided to staff in long-term-care environments.
Performance of TCP variants over LTE network
NASA Astrophysics Data System (ADS)
Nor, Shahrudin Awang; Maulana, Ade Novia
2016-08-01
One of the implementation of a wireless network is based on mobile broadband technology Long Term Evolution (LTE). LTE offers a variety of advantages, especially in terms of access speed, capacity, architectural simplicity and ease of implementation, as well as the breadth of choice of the type of user equipment (UE) that can establish the access. The majority of the Internet connections in the world happen using the TCP (Transmission Control Protocol) due to the TCP's reliability in transmitting packets in the network. TCP reliability lies in the ability to control the congestion. TCP was originally designed for wired media, but LTE connected through a wireless medium that is not stable in comparison to wired media. A wide variety of TCP has been made to produce a better performance than its predecessor. In this study, we simulate the performance provided by the TCP NewReno and TCP Vegas based on simulation using network simulator version 2 (ns2). The TCP performance is analyzed in terms of throughput, packet loss and end-to-end delay. In comparing the performance of TCP NewReno and TCP Vegas, the simulation result shows that the throughput of TCP NewReno is slightly higher than TCP Vegas, while TCP Vegas gives significantly better end-to-end delay and packet loss. The analysis of throughput, packet loss and end-to-end delay are made to evaluate the simulation.
Long-Term Stable Control of Motor-Imagery BCI by a Locked-In User Through Adaptive Assistance.
Saeedi, Sareh; Chavarriaga, Ricardo; Millan, Jose Del R
2017-04-01
Performance variation is one of the main challenges that BCIs are confronted with, when being used over extended periods of time. Shared control techniques could partially cope with such a problem. In this paper, we propose a taxonomy of shared control approaches used for BCIs and we review some of the recent studies at the light of these approaches. We posit that the level of assistance provided to the BCI user should be adjusted in real time in order to enhance BCI reliability over time. This approach has not been extensively studied in the recent literature on BCIs. In addition, we investigate the effectiveness of providing online adaptive assistance in a motor-imagery BCI for a tetraplegic end-user with an incomplete locked-in syndrome in a longitudinal study lasting 11 months. First, we report a reliable estimation of the BCI performance (in terms of command delivery time) using only a window of 1 s in the beginning of trials (AUC ≈ 0.8 ). Second, we demonstrate how adaptive shared control can exploit the output of the performance estimator to adjust online the level of assistance in a BCI game by regulating its speed. In particular, online adaptive assistance was superior to a fixed condition in terms of success rate ( ). Remarkably, the results exhibited a stable performance over severalmonths without recalibration of the BCI classifier or the performance estimator.
Jao, Ying-Ling; Mogle, Jacqueline; Williams, Kristine; McDermott, Caroline; Behrens, Liza
2018-04-01
Apathy is prevalent in individuals with dementia. Lack of responsiveness to environmental stimulation is a key characteristic of apathy. The Person-Environment Apathy Rating (PEAR) scale consists of environment and apathy subscales, which allow for examination of environmental impact on apathy. The interrater reliability of the PEAR scale was examined via real-time observation. The current study included 45 observations of 15 long-term care residents with dementia. Each participant was observed at three time points for 10 minutes each. Two raters observed the participant and surrounding environment and independently rated the participant's apathy and environmental stimulation using the PEAR scale. Weighted Kappa was 0.5 to 0.82 for the PEAR-Environment subscale and 0.5 to 0.8 for the PEAR-Apathy subscale. Overall, with the exception of three items with relatively weak reliability (0.50 to 0.56), the PEAR scale showed moderate to strong interrater reliability (0.63 to 0.82). The results support the use of the PEAR scale to measure environmental stimulation and apathy via real-time observation in long-term care residents with dementia. [Journal of Gerontological Nursing, 44(4), 23-28.]. Copyright 2018, SLACK Incorporated.
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Boomer, Kristen T.; Scheick, Leif; Lauenstein, Jean-Marie; Casey, Megan; Hammoud, Ahmad
2014-01-01
The power systems for use in NASA space missions must work reliably under harsh conditions including radiation, thermal cycling, and exposure to extreme temperatures. Gallium nitride semiconductors show great promise, but information pertaining to their performance is scarce. Gallium nitride N-channel enhancement-mode field effect transistors made by EPC Corporation in a 2nd generation of manufacturing were exposed to radiation followed by long-term thermal cycling and testing under high temperature reverse bias conditions in order to address their reliability for use in space missions. Result of the experimental work are presented and discussed.
Atmospheric Characterization of the US Offshore Sites and Impact on Turbine Performance (Poster)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arora, Dhiraj; Ehrmann, Robert; Zuo, Delong
Reliable, long term offshore atmospheric data is critical to development of the US offshore wind industry. There exists significant lack of meteorological, oceanographic, and geological data at potential US offshore sites. Assessment of wind resources at heights in the range of 25-200m is needed to understand and characterize offshore wind turbine performance. Data from the US Department of Energy owned WindSentinel buoy from two US offshore sites and one European site is analyzed. Low Level Jet (LLJ) phenomena and its potential impact on the performance of an offshore wind turbine is investigated.
Long-term outcomes of kidney and bladder function in patients with a posterior urethral valve.
Kim, Sung Jin; Jung, Jaeyoon; Lee, Chanwoo; Park, Sejun; Song, Sang Hoon; Won, Hye-Sung; Kim, Kun Suk
2018-06-01
We investigated long-term functional changes in the kidney and bladder of patients with posterior urethral valve (PUV) who underwent fetal intervention or postnatal surgery.We retrospectively reviewed the medical records of 28 consecutive patients treated for PUV at our institution. Detailed data on medical and surgical histories, particularly on pre- and postnatal treatment modality, including fetal vesicoamniotic shunt, endoscopic valve ablation, and vesicostomy, were collected and analyzed. Long-term renal function was evaluated based on serum levels of creatinine (sCr), estimated glomerular filtration rate (eGFR), and renal scans. Voiding function was evaluated in urodynamic tests.Vesicoamniotic shunting was performed in 12 (42.8%) patients. Although the mean initial sCr was significantly higher in patients in whom a fetal shunt was placed than in others (2.04 vs 1.17 mg/L, P = .038), the sCr at long-term follow-up was not significantly different between them (0.64 vs 0.40 mg/L, P = .186). The mean maximum detrusor pressure was significantly lower in patients with a fetal shunt than in others (37.7 vs 73.0 cm H2O, P = .019). Postnatal vesicostomy was performed in 14 patients, and primary valve ablation was performed in 13 patients. The mean initial sCr was higher in patients in the vesicostomy group than in the primary valve ablation group (2.08 vs 0.86 mg/L, P = .014). However, no significant differences were found in sCr (0.9 vs 0.3 mg/L, P = .252) or GFR (59.1 vs 68.5 mL/min/1.73 m, P = .338) at long-term follow-up. Bladder capacity was greater and residual urine volume was less in the vesicostomy group than in the primary valve ablation group, but without statistical significance.Vesicostomy is more beneficial in the recovery of renal function and is not inferior in terms of bladder function, even in patients with severe PUV disorder. It is a reliable surgical option that can spare renal function and guarantee adequate bladder function in the long term.
NASA Technical Reports Server (NTRS)
Van Vonno, N. W.
1972-01-01
Development of an alternate approach to the conventional methods of reliability assurance for large-scale integrated circuits. The product treated is a large-scale T squared L array designed for space applications. The concept used is that of qualification of product by evaluation of the basic processing used in fabricating the product, providing an insight into its potential reliability. Test vehicles are described which enable evaluation of device characteristics, surface condition, and various parameters of the two-level metallization system used. Evaluation of these test vehicles is performed on a lot qualification basis, with the lot consisting of one wafer. Assembled test vehicles are evaluated by high temperature stress at 300 C for short time durations. Stressing at these temperatures provides a rapid method of evaluation and permits a go/no go decision to be made on the wafer lot in a timely fashion.
Reliability of Modern Scores to Predict Long-Term Mortality After Isolated Aortic Valve Operations.
Barili, Fabio; Pacini, Davide; D'Ovidio, Mariangela; Ventura, Martina; Alamanni, Francesco; Di Bartolomeo, Roberto; Grossi, Claudio; Davoli, Marina; Fusco, Danilo; Perucci, Carlo; Parolari, Alessandro
2016-02-01
Contemporary scores for estimating perioperative death have been proposed to also predict also long-term death. The aim of the study was to evaluate the performance of the updated European System for Cardiac Operative Risk Evaluation II, The Society of Thoracic Surgeons Predicted Risk of Mortality score, and the Age, Creatinine, Left Ventricular Ejection Fraction score for predicting long-term mortality in a contemporary cohort of isolated aortic valve replacement (AVR). We also sought to develop for each score a simple algorithm based on predicted perioperative risk to predict long-term survival. Complete data on 1,444 patients who underwent isolated AVR in a 7-year period were retrieved from three prospective institutional databases and linked with the Italian Tax Register Information System. Data were evaluated with performance analyses and time-to-event semiparametric regression. Survival was 83.0% ± 1.1% at 5 years and 67.8 ± 1.9% at 8 years. Discrimination and calibration of all three scores both worsened for prediction of death at 1 year and 5 years. Nonetheless, a significant relationship was found between long-term survival and quartiles of scores (p < 0.0001). The estimated perioperative risk by each model was used to develop an algorithm to predict long-term death. The hazard ratios for death were 1.1 (95% confidence interval, 1.07 to 1.12) for European System for Cardiac Operative Risk Evaluation II, 1.34 (95% CI, 1.28 to 1.40) for the Society of Thoracic Surgeons score, and 1.08 (95% CI, 1.06 to 1.10) for the Age, Creatinine, Left Ventricular Ejection Fraction score. The predicted risk generated by European System for Cardiac Operative Risk Evaluation II, The Society of Thoracic Surgeons score, and Age, Creatinine, Left Ventricular Ejection Fraction scores cannot also be considered a direct estimate of the long-term risk for death. Nonetheless, the three scores can be used to derive an estimate of long-term risk of death in patients who undergo isolated AVR with the use of a simple algorithm. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
R&D of high reliable refrigeration system for superconducting generators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hosoya, T.; Shindo, S.; Yaguchi, H.
1996-12-31
Super-GM carries out R&D of 70 MW class superconducting generators (model machines), refrigeration system and superconducting wires to apply superconducting technology to electric power apparatuses. The helium refrigeration system for keeping field windings of superconducting generator (SCG) in cryogenic environment must meet the requirement of high reliability for uninterrupted long term operation of the SCG. In FY 1992, a high reliable conventional refrigeration system for the model machines was integrated by combining components such as compressor unit, higher temperature cold box and lower temperature cold box which were manufactured utilizing various fundamental technologies developed in early stage of the projectmore » since 1988. Since FY 1993, its performance tests have been carried out. It has been confirmed that its performance was fulfilled the development target of liquefaction capacity of 100 L/h and impurity removal in the helium gas to < 0.1 ppm. Furthermore, its operation method and performance were clarified to all different modes as how to control liquefaction rate and how to supply liquid helium from a dewar to the model machine. In addition, the authors have made performance tests and system performance analysis of oil free screw type and turbo type compressors which greatly improve reliability of conventional refrigeration systems. The operation performance and operational control method of the compressors has been clarified through the tests and analysis.« less
2009-09-01
capable of surviving the high-temperature, high- vibration environment of a jet engine. Active control spans active surge/stall control and three...other closely related areas, viz., active combustion control (references 21-22), active noise control, and active vibration control. All of these are...self-powered sensors that harvest energy from engine heat or vibrations replace sensors that require power. The long-term vision is one of a
Liu, Pengfei; Zhao, Qilin; Li, Fei; Liu, Jinchun; Chen, Haosen
2014-01-01
An assembled plane truss structure used for vehicle loading is designed and manufactured. In the truss, the glass fiber reinforced polymer (GFRP) tube and the steel joint are connected by a new technology featuring a pretightened tooth connection. The detailed description for the rod and node design is introduced in this paper, and a typical truss panel is fabricated. Under natural conditions, the short-term load test and long-term mechanical performance test for one year are performed to analyze its performance and conduct a comparative analysis for a reasonable FEM model. The study shows that the design and fabrication for the node of an assembled truss panel are convenient, safe, and reliable; because of the creep control design of the rods, not only does the short-term structural stiffness meet the design requirement but also the long-term creep deformation tends towards stability. In addition, no significant change is found in the elastic modules, so this structure can be applied in actual engineering. Although the safety factor for the strength of the composite rods is very large, it has a lightweight advantage over the steel truss for the low density of GFRP. In the FEM model, simplifying the node as a hinge connection relatively conforms to the actual status. PMID:25247203
Feasibility of Using Neural Network Models to Accelerate the Testing of Mechanical Systems
NASA Technical Reports Server (NTRS)
Fusaro, Robert L.
1998-01-01
Verification testing is an important aspect of the design process for mechanical mechanisms, and full-scale, full-length life testing is typically used to qualify any new component for use in space. However, as the required life specification is increased, full-length life tests become more costly and lengthen the development time. At the NASA Lewis Research Center, we theorized that neural network systems may be able to model the operation of a mechanical device. If so, the resulting neural network models could simulate long-term mechanical testing with data from a short-term test. This combination of computer modeling and short-term mechanical testing could then be used to verify the reliability of mechanical systems, thereby eliminating the costs associated with long-term testing. Neural network models could also enable designers to predict the performance of mechanisms at the conceptual design stage by entering the critical parameters as input and running the model to predict performance. The purpose of this study was to assess the potential of using neural networks to predict the performance and life of mechanical systems. To do this, we generated a neural network system to model wear obtained from three accelerated testing devices: 1) A pin-on-disk tribometer; 2) A line-contact rub-shoe tribometer; 3) A four-ball tribometer.
Liu, Pengfei; Zhao, Qilin; Li, Fei; Liu, Jinchun; Chen, Haosen
2014-01-01
An assembled plane truss structure used for vehicle loading is designed and manufactured. In the truss, the glass fiber reinforced polymer (GFRP) tube and the steel joint are connected by a new technology featuring a pretightened tooth connection. The detailed description for the rod and node design is introduced in this paper, and a typical truss panel is fabricated. Under natural conditions, the short-term load test and long-term mechanical performance test for one year are performed to analyze its performance and conduct a comparative analysis for a reasonable FEM model. The study shows that the design and fabrication for the node of an assembled truss panel are convenient, safe, and reliable; because of the creep control design of the rods, not only does the short-term structural stiffness meet the design requirement but also the long-term creep deformation tends towards stability. In addition, no significant change is found in the elastic modules, so this structure can be applied in actual engineering. Although the safety factor for the strength of the composite rods is very large, it has a lightweight advantage over the steel truss for the low density of GFRP. In the FEM model, simplifying the node as a hinge connection relatively conforms to the actual status.
Proven high-reliability assembly methods applied to avionics fiber-optics high-speed transceivers
NASA Astrophysics Data System (ADS)
Lauzon, Jocelyn; Leduc, Lorrain; Bessette, Daniel; Bélanger, Nicolas; Larose, Robert; Dion, Bruno
2012-06-01
Harsh environment avionics applications require operating temperature ranges that can extend to, and exceed -50 to 115°C. For obvious maintenance, management and cost arguments, product lifetimes as long as 20 years are also sought. This leads to mandatory long-term hermeticity that cannot be obtained with epoxy or silicone sealing; but only with glass seal or metal solder or brazing. A hermetic design can indirectly result in the required RF shielding of the component. For fiber-optics products, these specifications need to be compatible with the smallest possible size, weight and power consumption. The products also need to offer the best possible high-speed performances added to the known EMI immunity in the transmission lines. Fiber-optics transceivers with data rates per fiber channel up to 10Gbps are now starting to be offered on the market for avionics applications. Some of them are being developed by companies involved in the "normal environment" telecommunications market that are trying to ruggedize their products packaging in order to diversify their customer base. Another approach, for which we will present detailed results, is to go back to the drawing boards and design a new product that is adapted to proven MIL-PRF-38534 high-reliability packaging assembly methods. These methods will lead to the introduction of additional requirements at the components level; such as long-term high-temperature resistance for the fiber-optic cables. We will compare both approaches and demonstrate the latter, associated with the redesign, is the preferable one. The performance of the fiber-optic transceiver we have developed, in terms of qualification tests such as temperature cycling, constant acceleration, hermeticity, residual gaz analysis, operation under random vibration and mechanical shocks and accelerated lifetime tests will be presented. The tests are still under way, but so far, we have observed no performance degradation of such a product after more than 1050 hours of operation at 95°C.
Person-centred ward climate as experienced by mentally lucid residents in long-term care facilities.
Bergland, Ådel; Hofoss, Dag; Kirkevold, Marit; Vassbø, Tove; Edvardsson, David
2015-02-01
To assess the content validity and reliability of the Person-centred Climate Questionnaire-Patient version in long-term care facilities, to describe residents' perceptions of the extent to which their ward climate was person-centred and to explore whether person-centredness was associated with facility and resident characteristics, such as facility and ward size, having a sensory garden and having a primary caregiver. The importance of the physical environment to persons with dementia has been investigated. However, research is lacking regarding the extent to which mentally lucid residents experience their physical and psycho-social ward climate as person-centred and the factors influencing their experience. Cross-sectional survey design. The Person-centred Climate Questionnaire-Patient version was translated into Norwegian with forward and backward translation. The content validity index for scales was assessed. The Person-centred Climate Questionnaire -Patient version was completed by 145 mentally lucid residents in 17 Norwegian long-term care facilities. Reliability was assessed by Cronbach's α and item-total correlations. Test-retest reliability was assessed by paired samples t-test and Spearman's correlation. To explore differences based on facility and resident characteristics, independent-samples t-test and one-way anova were used. The content validity index for scales was satisfactory. The Person-centred Climate Questionnaire-Patient version was internally consistent and had satisfactory test-retest reliability. The climate was experienced as highly person-centred. No significant differences were found, except that residents in larger facilities experienced the climate as more person-centred in relation to everyday activities (subscale 2) than residents in smaller facilities. The Norwegian version of the Person-centred Climate Questionnaire-Patient version can be regarded as reliable in a long-term care facility context. Perceived degree of person-centredness was not associated with facility or resident characteristics, such as the number of residents, having a sensory garden or knowing that one has a primary caregiver. A person-centred climate can be attained in different kinds of long-term care facilities. © 2014 John Wiley & Sons Ltd.
Hsu, Ya-Chuan
2011-09-01
: Diverse social and recreational activities in elder care institutions have been provided to enrich a person's mental well-being amidst what is a relatively monotonous life. However, few instruments that measure the social activities of long-term care residents are available. : This study was designed to develop a culturally sensitive instrument (Socially Supportive Activity Inventory, SSAI) to assess quantity and quality of social activities for long-term care institutions and validate the instrument's psychometric properties. : The SSAI was developed on the basis of the social support theory, a synthesis of literature, and Taiwanese cultural mores. The instrument was rigorously subjected to a two-stage process to evaluate its reliability and validity. In Stage 1, six experts from diverse backgrounds were recruited to evaluate instrument items and estimate the content validity of the instrument using a content validity questionnaire. Items were modified and refined on the basis of the responses of the expert panel and a set of criteria. After obtaining approval from a university institutional review board, in the second stage of evaluating test-retest reliability, a convenience sample of 10 Taiwanese institutionalized elders in a pilot study, recruited from a nursing home, completed the revised instrument at two separate times over 2 weeks. : Results showed a content validity of .96. Test-retest reliability from a sample of 10 participants yielded stability coefficients of .76-1.00. The stability coefficient was 1.00 for the component of frequency, .76-1.00 for the component of meaningfulness, and .78-1.00 for the component of enjoyment. : The SSAI is a highly relevant and reliable culturally based instrument that can measure social activity in long-term care facilities. Because of the pilot nature of this study, future directions include further exploration of the SSAI instrument's psychometric properties. This should be done by enlarging the sample size to include more long-term care facilities and individual participants. Future studies can utilize diverse measures of social activity for comparison and validation of the SSAI.
Guida, Alessandro; Gras, Doriane; Noel, Yvonnick; Le Bohec, Olivier; Quaireau, Christophe; Nicolas, Serge
2013-05-01
In this study, a personalization method (Guida, Tardieu, & Nicolas, European Journal of Cognitive Psychology, 21: 862-896 2009) was applied to a free-recall task. Fifteen pairs of words, composed of an object and a location, were presented to 93 participants, who had to mentally associate each pair and subsequently recall the objects. A 30-s delay was introduced on half of the trials, the presentation rate was manipulated (5 or 10 s per item), and verbal and visuospatial working memory tests were administered to test for their effects on the serial curve. Two groups were constituted: a personalized group, for whom the locations were well-known places on their university campus, and a nonpersonalized group, for whom the locations did not refer to known places. Since personalization putatively operationalizes long-term working memory (Ericsson & Kintsch, Psychological Review, 102: 211-245 1995)-namely, the capacity to store information reliably and rapidly in long-term memory-and if we take a dual-store approach to memory, the personalization advantage would be expected to be greater for pre-recency than for recency items. Overall, the results were compatible with long-term working memory theory. They contribute to validating the personalization method as a methodology to characterize the contribution of long-term memory storage to performance in working memory tasks.
Combine Flash-Based FPGA TID and Long-Term Retention Reliabilities Through VT Shift
NASA Astrophysics Data System (ADS)
Wang, Jih-Jong; Rezzak, Nadia; Dsilva, Durwyn; Xue, Fengliang; Samiee, Salim; Singaraju, Pavan; Jia, James; Nguyen, Victor; Hawley, Frank; Hamdy, Esmat
2016-08-01
Reliability test results of data retention and total ionizing dose (TID) in 65 nm Flash-based field programmable gate array (FPGA) are presented. Long-chain inverter design is recommended for reliability evaluation because it is the worst case design for both effects. Based on preliminary test data, both issues are unified and modeled by one natural decay equation. The relative contributions of TID induced threshold-voltage shift and retention mechanisms are evaluated by analyzing test data.
Reliability improvements in tunable Pb1-xSnxSe diode lasers
NASA Technical Reports Server (NTRS)
Linden, K. J.; Butler, J. F.; Nill, K. W.; Reeder, R. E.
1980-01-01
Recent developments in the technology of Pb-salt diode lasers which have led to significant improvements in reliability and lifetime, and to improved operation at very long wavelengths are described. A combination of packaging and contacting-metallurgy improvements has led to diode lasers that are stable both in terms of temperature cycling and shelf-storage time. Lasers cycled over 500 times between 77 K and 300 K have exhibited no measurable changes in either electrical contact resistance or threshold current. Utilizing metallurgical contacting process, both lasers and experimental n-type and p-type bulk materials are shown to have electrical contact resistance values that are stable for shelf storage periods well in excess of one year. Problems and experiments which have led to devices with improved performance stability are discussed. Stable device configurations achieved for material compositions yielding lasers which operate continuously at wavelengths as long as 30.3 micrometers are described.
Electrical service reliability: the customer perspective
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samsa, M.E.; Hub, K.A.; Krohm, G.C.
1978-09-01
Electric-utility-system reliability criteria have traditionally been established as a matter of utility policy or through long-term engineering practice, generally with no supportive customer cost/benefit analysis as justification. This report presents results of an initial study of the customer perspective toward electric-utility-system reliability, based on critical review of over 20 previous and ongoing efforts to quantify the customer's value of reliable electric service. A possible structure of customer classifications is suggested as a reasonable level of disaggregation for further investigation of customer value, and these groups are characterized in terms of their electricity use patterns. The values that customers assign tomore » reliability are discussed in terms of internal and external cost components. A list of options for effecting changes in customer service reliability is set forth, and some of the many policy issues that could alter customer-service reliability are identified.« less
NASA Astrophysics Data System (ADS)
Vasudevan, Srikanth; Patel, Kunal; Welle, Cristin
2017-02-01
Objective. In the US alone, there are approximately 185 000 cases of limb amputation annually, which can reduce the quality of life for those individuals. Current prosthesis technology could be improved by access to signals from the nervous system for intuitive prosthesis control. After amputation, residual peripheral nerves continue to convey motor signals and electrical stimulation of these nerves can elicit sensory percepts. However, current technology for extracting information directly from peripheral nerves has limited chronic reliability, and novel approaches must be vetted to ensure safe long-term use. The present study aims to optimize methods to establish a test platform using rodent model to assess the long term safety and performance of electrode interfaces implanted in the peripheral nerves. Approach. Floating Microelectrode Arrays (FMA, Microprobes for Life Sciences) were implanted into the rodent sciatic nerve. Weekly in vivo recordings and impedance measurements were performed in animals to assess performance and physical integrity of electrodes. Motor (walking track analysis) and sensory (Von Frey) function tests were used to assess change in nerve function due to the implant. Following the terminal recording session, the nerve was explanted and the health of axons, myelin and surrounding tissues were assessed using immunohistochemistry (IHC). The explanted electrodes were visualized under high magnification using scanning electrode microscopy (SEM) to observe any physical damage. Main results. Recordings of axonal action potentials demonstrated notable session-to-session variability. Impedance of the electrodes increased upon implantation and displayed relative stability until electrode failure. Initial deficits in motor function recovered by 2 weeks, while sensory deficits persisted through 6 weeks of assessment. The primary cause of failure was identified as lead wire breakage in all of animals. IHC indicated myelinated and unmyelinated axons near the implanted electrode shanks, along with dense cellular accumulations near the implant site. Scanning electron microscopy (SEM) showed alterations of the electrode insulation and deformation of electrode shanks. Significance. We describe a comprehensive testing platform with applicability to electrodes that record from the peripheral nerves. This study assesses the long term safety and performance of electrodes in the peripheral nerves using a rodent model. Under this animal test platform, FMA electrodes record single unit action potentials but have limited chronic reliability due to structural weaknesses. Future work will apply these methods to other commercially-available and novel peripheral electrode technologies. This research was carried out in the Division of Biomedical Physics, Office of Science and Engineering Laboratory, Center for Devices and Radiological Health, US Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA.
Long-term pitch memory for music recordings is related to auditory working memory precision.
Van Hedger, Stephen C; Heald, Shannon Lm; Nusbaum, Howard C
2018-04-01
Most individuals have reliable long-term memories for the pitch of familiar music recordings. This pitch memory (1) appears to be normally distributed in the population, (2) does not depend on explicit musical training and (3) only seems to be weakly related to differences in listening frequency estimates. The present experiment was designed to assess whether individual differences in auditory working memory could explain variance in long-term pitch memory for music recordings. In Experiment 1, participants first completed a musical note adjustment task that has been previously used to assess working memory of musical pitch. Afterward, participants were asked to judge the pitch of well-known music recordings, which either had or had not been shifted in pitch. We found that performance on the pitch working memory task was significantly related to performance in the pitch memory task using well-known recordings, even when controlling for overall musical experience and familiarity with each recording. In Experiment 2, we replicated these findings in a separate group of participants while additionally controlling for fluid intelligence and non-pitch-based components of auditory working memory. In Experiment 3, we demonstrated that participants could not accurately judge the pitch of unfamiliar recordings, suggesting that our method of pitch shifting did not result in unwanted acoustic cues that could have aided participants in Experiments 1 and 2. These results, taken together, suggest that the ability to maintain pitch information in working memory might lead to more accurate long-term pitch memory.
Neon reduction program on Cymer ArF light sources
NASA Astrophysics Data System (ADS)
Kanawade, Dinesh; Roman, Yzzer; Cacouris, Ted; Thornes, Josh; O'Brien, Kevin
2016-03-01
In response to significant neon supply constraints, Cymer has responded with a multi-part plan to support its customers. Cymer's primary objective is to ensure that reliable system performance is maintained while minimizing gas consumption. Gas algorithms were optimized to ensure stable performance across all operating conditions. The Cymer neon support plan contains four elements: 1. Gas reduction program to reduce neon by >50% while maintaining existing performance levels and availability; 2. short-term containment solutions for immediate relief. 3. qualification of additional gas suppliers; and 4. long-term recycling/reclaim opportunity. The Cymer neon reduction program has shown excellent results as demonstrated through the comparison on standard gas use versus the new >50% reduced neon performance for ArF immersion light sources. Testing included stressful conditions such as repetition rate, duty cycle and energy target changes. No performance degradation has been observed over typical gas lives.
Controlling surface property of K2SiF6:Mn4+ for improvement of lighting-emitting diode reliability
NASA Astrophysics Data System (ADS)
Kim, Juseong; Jang, Inseok; Song, Gwang Yeom; Kim, Wan-Ho; Jeon, Sie-Wook; Kim, Jae-Pil
2018-05-01
The surface property of moisture-sensitive K2SiF6:Mn4+ (KSF) as a red-emitting phosphor was controlled through dry-type surface modification in order to improve the photo-performance and reliability of lighting-emitting diode (LED). The phosphor surface was modified with silane coupling agents having different carbon chain length by plasma-assisted method. Comparing between as-prepared and modified KSF, water-resistance and photo-emission efficiency were enhanced due to the formation of hydrophobic shell and the elimination of surface quenching sites. Moreover, the dispersibility of phosphor was increased as increasing the carbon chain length of silane because the interfacial affinity between phosphor and encapsulant was improved. After fabricating LED device, the enhancement of photo-performance and long-term reliability could be successfully achieved in LED device with modified phosphor. It is attributed to that the degradation of phosphor efficiency by moisture was suppressed and heat dissipation in LED PKG was improved through the surface modification.
NASA Technical Reports Server (NTRS)
Tien, John K.
1990-01-01
The long term interdiffusional stability of tungsten fiber reinforced niobium alloy composites is addressed. The matrix alloy that is most promising for use as a high temperature structural material for reliable long-term space power generation is Nb1Zr. As an ancillary project to this program, efforts were made to assess the nature and kinetics of interphase reaction between selected beryllide intermetallics and nickel and iron aluminides.
Wang, Yong; Lee, Dongyoung; Zhang, Lisa; Jeon, Hyojin; Mendoza-Elias, Joshua E.; Harvat, Tricia A.; Hassan, Sarah Z.; Zhou, Amanda; Eddington, David T.; Oberholzer, José
2012-01-01
Reliable long-term cell culture in microfluidic system is limited by air bubble formation and accumulation. In this study, we developed a bubble removal system capable of both trapping and discharging air bubbles in a consistent and reliable manner. Combined with PDMS (Polydimethylsiloxane) hydrophilic surface treatment and vacuum filling, a microfluidic perifusion system equipped with the bubble trap was successfully applied for long-term culture of mouse pancreatic islets with no bubble formation and no flow interruption. In addition to demonstrating normal cell viability and islet morphology, post-cultured islets exhibited normal insulin secretion kinetics, intracellular calcium signaling, and changes in mitochondrial potentials in response to glucose challenge. This design could be easily adapted by other microfluidic systems due to its simple design, ease of fabrication, and portability. PMID:22252566
NASA Astrophysics Data System (ADS)
Dulo, D. A.
Safety critical software systems permeate spacecraft, and in a long term venture like a starship would be pervasive in every system of the spacecraft. Yet software failure today continues to plague both the systems and the organizations that develop them resulting in the loss of life, time, money, and valuable system platforms. A starship cannot afford this type of software failure in long journeys away from home. A single software failure could have catastrophic results for the spaceship and the crew onboard. This paper will offer a new approach to developing safe reliable software systems through focusing not on the traditional safety/reliability engineering paradigms but rather by focusing on a new paradigm: Resilience and Failure Obviation Engineering. The foremost objective of this approach is the obviation of failure, coupled with the ability of a software system to prevent or adapt to complex changing conditions in real time as a safety valve should failure occur to ensure safe system continuity. Through this approach, safety is ensured through foresight to anticipate failure and to adapt to risk in real time before failure occurs. In a starship, this type of software engineering is vital. Through software developed in a resilient manner, a starship would have reduced or eliminated software failure, and would have the ability to rapidly adapt should a software system become unstable or unsafe. As a result, long term software safety, reliability, and resilience would be present for a successful long term starship mission.
Good, Eric D; Cakulev, Ivan; Orlov, Michael V; Hirsh, David; Simeles, John; Mohr, Kelly; Moll, Phil; Bloom, Heather
2016-06-01
Expert consensus holds that post-market, systematic surveillance of ICD leads is essential to ensure confirmation of adequate lead performance. GALAXY (NCT00836589) and CELESTIAL (NCT00810264) are ongoing multicenter, prospective, non-randomized registries conducted to confirm the long-term safety and reliability of Biotronik leads. ICD and CRT-D patients are followed for Linox and Linox(smart) ICD lead performance and safety for 5 years post-implant. All procedural and system-related adverse events (AEs) were assessed at each follow-up, along with lead electrical parameters. An independent CEC of EPs adjudicated AEs to determine AE category and lead relatedness. The analysis used categories of lead observations per ISO 5841-2 (Third edition). A total of 3,933 leads were implanted in 3,840 patients (73.0% male, mean age 67.0 ± 12.2 years) at 146 US centers. The estimated cumulative survival probability was 96.3% at 5 years after implant for Linox leads and 96.6% at 4 years after implant for Linox(smart) leads. A comparison of the Linox and Linox(smart) survival functions did not find evidence of a difference (P = 0.2155). The most common AEs were oversensing (23, 0.58%), conductor fracture (14, 0.36%), failure to capture (13, 0.33%), lead dislodgement (12, 0.31%), insulation breach (10, 0.25%), and abnormal pacing impedance (8, 0.20%). Linox and Linox(smart) ICD leads are safe, reliable and infrequently associated with lead-related AEs. Additionally, estimated cumulative survival probability is clinically acceptable and well within industry standards. Ongoing data collection will confirm the longer-term safety and performance of the Linox family of ICD leads. © 2016 Wiley Periodicals, Inc.
Hosang, Leon; Yusifov, Rashad; Löwel, Siegrid
2018-01-01
For routine behavioral tasks, mice predominantly rely on olfactory cues and tactile information. In contrast, their visual capabilities appear rather restricted, raising the question whether they can improve if vision gets more behaviorally relevant. We therefore performed long-term training using the visual water task (VWT): adult standard cage (SC)-raised mice were trained to swim toward a rewarded grating stimulus so that using visual information avoided excessive swimming toward nonrewarded stimuli. Indeed, and in contrast to old mice raised in a generally enriched environment (Greifzu et al., 2016), long-term VWT training increased visual acuity (VA) on average by more than 30% to 0.82 cycles per degree (cyc/deg). In an individual animal, VA even increased to 1.49 cyc/deg, i.e., beyond the rat range of VAs. Since visual experience enhances the spatial frequency threshold of the optomotor (OPT) reflex of the open eye after monocular deprivation (MD), we also quantified monocular vision after VWT training. Monocular VA did not increase reliably, and eye reopening did not initiate a decline to pre-MD values as observed by optomotry; VA values rather increased by continued VWT training. Thus, optomotry and VWT measure different parameters of mouse spatial vision. Finally, we tested whether long-term MD induced ocular dominance (OD) plasticity in the visual cortex of adult [postnatal day (P)162-P182] SC-raised mice. This was indeed the case: 40-50 days of MD induced OD shifts toward the open eye in both VWT-trained and, surprisingly, also in age-matched mice without VWT training. These data indicate that (1) long-term VWT training increases adult mouse VA, and (2) long-term MD induces OD shifts also in adult SC-raised mice.
Application of long-term microdialysis in circadian rhythm research
Borjigin, Jimo; Liu, Tiecheng
2008-01-01
Our laboratory has pioneered long-term microdialysis to monitor pineal melatonin secretion in living animals across multiple circadian cycles. There are numerous advantages of this approach for rhythm analysis: (1) we can precisely define melatonin onset and offset phases; (2) melatonin is a reliable and stable neuroendocrine output of the circadian clock (versus behavioral output which is sensitive to stress or other factors); (3) melatonin measurements can be performed extremely frequently, permitting high temporal resolution (10 min sampling intervals), which allows detection of slight changes in phase; (4) the measurements can be performed for more than four weeks, allowing perturbations of the circadian clock to be followed long-term in the same animals; (5) this is an automated process (microdialysis coupled with on-line HPLC analysis), which increases accuracy and bypasses the labor-intensive and error-prone manual handling of dialysis samples; and (6) our approach allows real-time investigation of circadian rhythm function and permits appropriate timely adjustments of experimental conditions. The longevity of microdialysis probes, the key to the success of this approach, depends at least in part on the methods of the construction and implantation of dialysis probes. In this article, we have detailed the procedures of construction and surgical implantation of microdialysis probes used currently in our laboratory, which are significantly improved from our previous methods. PMID:18045670
Ferret lung transplant: an orthotopic model of obliterative bronchiolitis.
Sui, H; Olivier, A K; Klesney-Tait, J A; Brooks, L; Tyler, S R; Sun, X; Skopec, A; Kline, J; Sanchez, P G; Meyerholz, D K; Zavazava, N; Iannettoni, M; Engelhardt, J F; Parekh, K R
2013-02-01
Obliterative bronchiolitis (OB) is the primary cause of late morbidity and mortality following lung transplantation. Current animal models do not reliably develop OB pathology. Given the similarities between ferret and human lung biology, we hypothesized an orthotopic ferret lung allograft would develop OB. Orthotopic left lower lobe transplants were successfully performed in 22 outbred domestic ferrets in the absence of immunosuppression (IS; n = 5) and presence of varying IS protocols (n = 17). CT scans were performed to evaluate the allografts. At intervals between 3-6 months the allografts were examined histologically for evidence of acute/chronic rejection. IS protects allografts from acute rejection and early graft loss. Reduction of IS dosage by 50% allowed development of controlled rejection. Allografts developed infiltrates on CT and classic histologic acute rejection and lymphocytic bronchiolitis. Cycling of IS, to induce repeated episodes of controlled rejection, promoted classic histologic hallmarks of OB including fibrosis-associated occlusion of the bronchiolar airways in all allografts of long-term survivors. In conclusion, we have developed an orthotopic lung transplant model in the ferret with documented long-term functional allograft survival. Allografts develop acute rejection and lymphocytic bronchiolitis, similar to humans. Long-term survivors develop histologic changes in the allografts that are hallmarks of OB. © Copyright 2012 The American Society of Transplantation and the American Society of Transplant Surgeons.
Long-term Blood Pressure Measurement in Freely Moving Mice Using Telemetry.
Alam, Mohammad Afaque; Parks, Cory; Mancarella, Salvatore
2016-05-17
During the development of new vasoactive agents, arterial blood pressure monitoring is crucial for evaluating the efficacy of the new proposed drugs. Indeed, research focusing on the discovery of new potential therapeutic targets using genetically altered mice requires a reliable, long-term assessment of the systemic arterial pressure variation. Currently, the gold standard for obtaining long-term measurements of blood pressure in ambulatory mice uses implantable radio-transmitters, which require artery cannulation. This technique eliminates the need for tethering, restraining, or anesthetizing the animals which introduce stress and artifacts during data sampling. However, arterial blood pressure monitoring in mice via catheterization can be rather challenging due to the small size of the arteries. Here we present a step-by-step guide to illustrate the crucial key passages for a successful subcutaneous implantation of radio-transmitters and carotid artery cannulation in mice. We also include examples of long-term blood pressure activity taken from freely moving mice after a period of post-surgery recovery. Following this procedure will allow reliable direct blood pressure recordings from multiple animals simultaneously.
NASA Astrophysics Data System (ADS)
Degueldre, Claude; Gomez Briceño, Dolores; Fanghänel, Thomas; Warin, Dominique
2006-06-01
These proceedings provide papers that were presented at the Symposium N 'Nuclear Materials' of the EMRS Spring meeting 05, held from May 31 to June 2, 2005 at the Palais des Congrés in Strasbourg. The Symposium concerned materials that are applied in the nuclear environment and that are studied for their specific utilisation under demanding temperature, pressure and irradiation environments. Most of these materials act as barrier and their structural properties are investigated with emphasis on mechanical performances, reliability and long-term behaviour.
Koschwanez, Heidi E.; Reichert, W. Monty
2007-01-01
To date, there have been a number of cases where glucose sensors have performed well over long periods of implantation; however, it remains difficult to predict whether a given sensor will perform reliably, will exhibit gradual degradation of performance, or will fail outright soon after implantation. Typically, the literature emphasizes the sensor that performed well, while only briefly (if at all) mentioning the failed devices. This leaves open the question of whether current sensor designs are adequate for the hostile in vivo environment, and whether these sensors have been assessed by the proper regimen of testing protocols. This paper reviews the current in vitro and in vivo testing procedures used to evaluate the functionality and biocompatibility of implantable glucose sensors. An overview of the standards and regulatory bodies that govern biomaterials and end-product device testing precedes a discussion of up-to-date invasive and non-invasive technologies for diabetes management. Analysis of current in vitro, in vivo, and then post implantation testing is presented. Given the underlying assumption that the success of the sensor in vivo foreshadows the long-term reliability of the sensor in the human body, the relative merits of these testing methods are evaluated with respect to how representative they are of human models. PMID:17524479
Use of Drying Technologies for Resource Recovery from Solid Wastes and Brines
NASA Technical Reports Server (NTRS)
Wignarajah, Kanapathipillai; Alba, Ric; Fisher, John W.; Hogan, John A.; Polonsky, Alex
2010-01-01
Long term storage of unprocessed biological wastes and human wastes can present major health issues and a loss of potential resources. Space vehicles and planetary habitats are typically resource-scarce or resource-limited environments for long-term human habitation. To-date, most of the resources will need to be supplied from Earth, but this may not be possible for long duration human exploration. Based on present knowledge, there is only very limited in-situ resources on planetary habitats. Hence, the opportunity to "live off the land" in a planetary habitat is limited. However, if we assume that wastes generated by human explorers are viewed as resources, there is great potential to utilize and recycle them, thereby reducing the requirements for supply Earth and enabling the "live off the land" exploration scenario. Technologies used for the recovery of resources from wastes should be reliable, safe, easy to operate, fail-proof, modular, automated and preferably multifunctional in being capable of handling mixed solid and liquid wastes. For a lunar habitat, energy does not appear to be the major driving factor amongst the technologies studied. Instead, reliability appears to be more important[1] . This paper reports studies to date on drying technologies to remove water from solid wastes and brines. Experimental performance data obtained for recovery water from wastes and brine are presented. Simplicity of operation of hardware and energy efficiency are discussed. Some improvements and modifications to hardware were performed. Hopefully, this information will assist in future efforts in the "downselection" of technologies for recovery of water and resources from solid wastes and brines.
NASA Astrophysics Data System (ADS)
Weisenburger, A.; Schroer, C.; Jianu, A.; Heinzel, A.; Konys, J.; Steiner, H.; Müller, G.; Fazio, C.; Gessi, A.; Babayan, S.; Kobzova, A.; Martinelli, L.; Ginestar, K.; Balbaud-Célerier, F.; Martín-Muñoz, F. J.; Soler Crespo, L.
2011-08-01
Considering the status of knowledge on corrosion and corrosion protection and especially the need for long term compatibility data of structural materials in HLM a set of experiments to generate reliable long term data was defined and performed. The long term corrosion behaviour of the two structural materials foreseen in ADS, 316L and T91, was investigated in the design relevant temperature field, i.e. from 300 to 550 °C. The operational window of the two steels in this temperature range was identified and all oxidation data were used to develop and validate the models of oxide scale growth in PbBi. A mechanistic model capable to predict the oxidation rate applying some experimentally fitted parameters has been developed. This model assumes parabolic oxidation and might be used for design and safety relevant investigations in future. Studies on corrosion barrier development allowed to define the required Al content for the formation of thin alumina scales in LBE. These results as well as future steps and required improvements are discussed. Variation of experimental conditions clearly showed that specific care has to be taken with respect to local flow conditions and oxygen concentrations.
Reliability Assessment Approach for Stirling Convertors and Generators
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Schreiber, Jeffrey G.; Zampino, Edward; Best, Timothy
2004-01-01
Stirling power conversion is being considered for use in a Radioisotope Power System for deep-space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power. Quantifying the reliability of a Radioisotope Power System that utilizes Stirling power conversion technology is important in developing and demonstrating the capability for long-term success. A description of the Stirling power convertor is provided, along with a discussion about some of the key components. Ongoing efforts to understand component life, design variables at the component and system levels, related sources, and the nature of uncertainties is discussed. The requirement for reliability also is discussed, and some of the critical areas of concern are identified. A section on the objectives of the performance model development and a computation of reliability is included to highlight the goals of this effort. Also, a viable physics-based reliability plan to model the design-level variable uncertainties at the component and system levels is outlined, and potential benefits are elucidated. The plan involves the interaction of different disciplines, maintaining the physical and probabilistic correlations at all the levels, and a verification process based on rational short-term tests. In addition, both top-down and bottom-up coherency were maintained to follow the physics-based design process and mission requirements. The outlined reliability assessment approach provides guidelines to improve the design and identifies governing variables to achieve high reliability in the Stirling Radioisotope Generator design.
Long-Term Reliability of SiGe/Si HBTs From Accelerated Lifetime Testing
NASA Technical Reports Server (NTRS)
Bhattacharya, Pallab
2001-01-01
Accelerated lifetime tests were performed on double-mesa structure Si(0.7)Ge(0.3)/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175 C-275 C. The transistors (with 5x20 sq micron emitter area) have DC current gains approx. 40-50 and f(sub T) and f(sub max) of up to 22 GHz and 25 GHz, respectively. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REED has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of these devices at room temperature under 1.35 x 10(exp 4) A/sq cm current density operation is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation.
Dual- versus single-coil implantable defibrillator leads: review of the literature.
Neuzner, Jörg; Carlsson, Jörg
2012-04-01
The preferred use of dual-coil implantable defibrillator lead systems in current implantable defibrillator therapy is likely based on data showing statistically lower defibrillation thresholds with dual-coil defibrillator lead systems. The following review will summarize the clinical data for dual- versus single-coil defibrillator leads in the left and right pectoral implant locations, and will then discuss the clinical implications of single- versus dual-coil usage for atrial defibrillation, venous complications, and the risks associated with lead extraction. It will be noted that there are no comparative clinical studies on the use and outcomes of single- versus dual-coil lead systems in implantable defibrillator therapy over a long-term follow-up. The limited long-term reliability of defibrillator leads is a major concern in implantable defibrillator and cardiac resynchronization therapy. A simpler single-coil defibrillator lead system may improve the long-term performance of implanted leads. Furthermore, the superior vena cava coil is suspected to increase interventional risk in transvenous lead extraction. Therefore, the need for objective data on extractions and complications will be emphasized.
NASA Astrophysics Data System (ADS)
Noh, J.; Russo, S.
2017-08-01
Long-term dynamic monitoring of the masonry façade of Palazzo Ducale known as Doge's palace in Venice, Italy was performed from September 2010 to October 2012. This article demonstrates the results of preliminary analysis on the data set of the first 12-month long monitoring campaign for out-of-plumb dynamic responses of the medieval façade of the monument. The aim of the analysis of the dynamic signals is to validate the data set and investigate dynamic characteristics of the vibration signature of the historical masonry wall in the long-term. Palazzo Ducale is a heavily visited heritage due to its high cultural importance and architectural value. Nevertheless, little is known about the dynamic behaviour of the double-leaf masonry façade. In this study, the dynamic properties of the structure are presented by dynamic identification carried out with the effect of the ambient vibration measured at four different locations on the façade and portico level. The trend and intensity of the vibration at each measurement locations are identified over the year. In addition, the issue on eliminating the noise blended in the signals for reliable analysis are also discussed.
Adamo, Federica; Farina, Marco; Thekkedath, Usha R; Grattoni, Alessandro; Sesana, Raffaella
2018-06-01
Cell transplantation in bioengineered scaffolds and encapsulation systems has shown great promise in regenerative medicine. Depending on the site of implantation, type of cells and their expected function, these systems are designed to provide cells with a physiological-like environment while providing mechanical support and promoting long-term viability and function of the graft. A minimally invasive 3D printed system termed neovascularized implantable cell homing and encapsulation (NICHE) was developed in polylactic acid for subcutaneous transplantation of endocrine cells, including pancreatic islets. The suitability of the NICHE for long term in vivo deployment is investigated by assessing mechanical behavior of both fresh devices under simulated subcutaneous conditions and NICHE retrieved from subcutaneous implantation in pigs. Both experimental and numerical studies were performed with a focus on validating the constitutive material model used in the numerical analysis for accuracy and reliability. Notably, homogeneous isotropic constitutive material model calibrated by means of uniaxial testing well suited experimental results. The results highlight the long term durability for in vivo applications and the potential applicability of the model to predict the mechanical behavior of similar devices in various physiological settings. Copyright © 2018 Elsevier Ltd. All rights reserved.
Zhang, Quan; Chen, Zheng; Chen, Shenghuo; Xu, Youyun; Deng, Huihua
2017-02-01
Cortisol, cortisone and the ratio of cortisol to cortisone in saliva, urine and hair are acute, short-term and long-term biomarkers to reliably assess the activity of hypothalamic-pituitary-adrenal (HPA) axis and 11β-hydroxysteroid dehydrogenase (11β-HSD). One key issue is whether these biomarkers have intraindividual relative stability. Salivary, urinary and hair cortisol was proven to show considerable long-term intraindividual relative stability. However, currently unknown is whether cortisone and the ratio in saliva, urine and hair show intraindividual relative stability. The present study utilized a longitudinal design to validate long-term stability within two weeks of three biomarkers in saliva and urine, and long-term stability within twelve months of three hair biomarkers. Salivary, urinary and hair steroids were measured with high performance liquid chromatography tandem mass spectrometry. Three biomarkers in urine and hair showed moderate test-retest correlations with coefficient (r) ranging between 0.22 and 0.56 and good multiple-test consistencies with coefficient of intraclass correlation (ICC) ranging between 0.42 and 0.67. Three single-point salivary biomarkers showed weak to moderate test-retest correlations (r's between 0.01 and 0.38) and poor to fair multiple-test consistencies (ICC's between 0.29 and 0.53) within two weeks. Three single-day salivary biomarkers showed moderate test-retest correlations (r's between 0.23 and 0.53) and good multiple-test consistencies (ICC's between 0.56 and 0.66) within two weeks. Three biomarkers in urine and hair showed moderate long-term intraindividual relative stability. Three single-point salivary biomarkers showed weak to moderate short-term and long-term intraindividual relative stability, but three single-day salivary biomarkers showed moderate short-term and long-term intraindividual relative stability. Copyright © 2016 Elsevier Inc. All rights reserved.
Chen, Bo-Wei; Chang, Ting-Chang; Chang, Kuan-Chang; Hung, Yu-Ju; Huang, Shin-Ping; Chen, Hua-Mao; Liao, Po-Yung; Lin, Yu-Ho; Huang, Hui-Chun; Chiang, Hsiao-Cheng; Yang, Chung-I; Zheng, Yu-Zhe; Chu, Ann-Kuo; Li, Hung-Wei; Tsai, Chih-Hung; Lu, Hsueh-Hsing; Wang, Terry Tai-Jui; Chang, Tsu-Chiang
2017-04-05
The surface morphology in polycrystalline silicon (poly-Si) film is an issue regardless of whether conventional excimer laser annealing (ELA) or the newer metal-induced lateral crystallization (MILC) process is used. This paper investigates the stress distribution while undergoing long-term mechanical stress and the influence of stress on electrical characteristics. Our simulated results show that the nonuniform stress in the gate insulator is more pronounced near the polysilicon/gate insulator edge and at the two sides of the polysilicon protrusion. This stress results in defects in the gate insulator and leads to a nonuniform degradation phenomenon, which affects both the performance and the reliability in thin-film transistors (TFTs). The degree of degradation is similar regardless of bending axis (channel-length axis, channel-width axis) or bending type (compression, tension), which means that the degradation is dominated by the protrusion effects. Furthermore, by utilizing long-term electrical bias stresses after undergoing long-tern bending stress, it is apparent that the carrier injection is severe in the subchannel region, which confirms that the influence of protrusions is crucial. To eliminate the influence of surface morphology in poly-Si, three kinds of laser energy density were used during crystallization to control the protrusion height. The device with the lowest protrusions demonstrates the smallest degradation after undergoing long-term bending.
Soliman, Ivo W; Cremer, Olaf L; de Lange, Dylan W; Slooter, Arjen J C; van Delden, Johannes Hans J M; van Dijk, Diederik; Peelen, Linda M
2018-02-01
To assess the reliability of physicians' prognoses for intensive care unit (ICU) survivors with respect to long-term survival and health related quality of life (HRQoL). We performed an observational cohort-study in a single mixed tertiary ICU in The Netherlands. ICU survivors with a length of stay >48h were included. At ICU discharge, one-year prognosis was estimated by physicians using the four-option Sabadell score to record their expectations. The outcome of interest was poor outcome, which was defined as dying within one-year follow-up, or surviving with an EuroQoL5D-3L index <0.4. Among 1399 ICU survivors, 1068 (76%) subjects were expected to have a good outcome; 243 (18%) a poor long-term prognosis; 43 (3%) a poor short-term prognosis, and 45 (3%) to die in hospital (i.e. Sabadell score levels). Poor outcome was observed in 38%, 55%, 86%, and 100% of these groups respectively (concomitant c-index: 0.61). The expected prognosis did not match observed outcome in 365 (36%) patients. This was almost exclusively (99%) due to overoptimism. Physician experience did not affect results. Prognoses estimated by physicians incorrectly predicted long-term survival and HRQoL in one-third of ICU survivors. Moreover, inaccurate prognoses were generally the result of overoptimistic expectations of outcome. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bertoni, Federica; Giuliani, Matteo; Castelletti, Andrea
2017-04-01
Over the past years, many studies have looked at the planning and management of water infrastructure systems as two separate problems, where the dynamic component (i.e., operations) is considered only after the static problem (i.e., planning) has been resolved. Most recent works have started to investigate planning and management as two strictly interconnected faces of the same problem, where the former is solved jointly with the latter in an integrated framework. This brings advantages to multi-purpose water reservoir systems, where several optimal operating strategies exist and similar system designs might perform differently on the long term depending on the considered short-term operating tradeoff. An operationally robust design will be therefore one performing well across multiple feasible tradeoff operating policies. This work aims at studying the interaction between short-term operating strategies and their impacts on long-term structural decisions, when long-lived infrastructures with complex ecological impacts and multi-sectoral demands to satisfy (i.e., reservoirs) are considered. A parametric reinforcement learning approach is adopted for nesting optimization and control yielding to both optimal reservoir design and optimal operational policies for water reservoir systems. The method is demonstrated on a synthetic reservoir that must be designed and operated for ensuring reliable water supply to downstream users. At first, the optimal design capacity derived is compared with the 'no-fail storage' computed through Rippl, a capacity design function that returns the minimum storage needed to satisfy specified water demands without allowing supply shortfall. Then, the optimal reservoir volume is used to simulate the simplified case study under other operating objectives than water supply, in order to assess whether and how the system performance changes. The more robust the infrastructural design, the smaller the difference between the performances of different operating strategies.
Applying RUG-III in Japanese Long-Term Care Facilities.
ERIC Educational Resources Information Center
Ikegami, Naoki; And Others
1994-01-01
Tested U.S. nursing home case-mix system, Resource Utilization Groups, Version III (RUG-III) in Japanese long-term care facilities. Measured staff time and resident characteristics for 871 patients. Found acceptable reliability for items defining RUG-III, and system explained 44% of variance in wage-weighted staff time (cost). Japanese and U.S.…
Evolution of Wholesale Electricity Market Design with Increasing Levels of Renewable Generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ela, E.; Milligan, M.; Bloom, A.
2014-09-01
Variable generation such as wind and photovoltaic solar power has increased substantially in recent years. Variable generation has unique characteristics compared to the traditional technologies that supply energy in the wholesale electricity markets. These characteristics create unique challenges in planning and operating the power system, and they can also influence the performance and outcomes from electricity markets. This report focuses on two particular issues related to market design: revenue sufficiency for long-term reliability and incentivizing flexibility in short-term operations. The report provides an overview of current design and some designs that have been proposed by industry or researchers.
Implications of scaling on static RAM bit cell stability and reliability
NASA Astrophysics Data System (ADS)
Coones, Mary Ann; Herr, Norm; Bormann, Al; Erington, Kent; Soorholtz, Vince; Sweeney, John; Phillips, Michael
1993-01-01
In order to lower manufacturing costs and increase performance, static random access memory (SRAM) bit cells are scaled progressively toward submicron geometries. The reliability of an SRAM is highly dependent on the bit cell stability. Smaller memory cells with less capacitance and restoring current make the array more susceptible to failures from defectivity, alpha hits, and other instabilities and leakage mechanisms. Improving long term reliability while migrating to higher density devices makes the task of building in and improving reliability increasingly difficult. Reliability requirements for high density SRAMs are very demanding with failure rates of less than 100 failures per billion device hours (100 FITs) being a common criteria. Design techniques for increasing bit cell stability and manufacturability must be implemented in order to build in this level of reliability. Several types of analyses are performed to benchmark the performance of the SRAM device. Examples of these analysis techniques which are presented here include DC parametric measurements of test structures, functional bit mapping of the circuit used to characterize the entire distribution of bits, electrical microprobing of weak and/or failing bits, and system and accelerated soft error rate measurements. These tests allow process and design improvements to be evaluated prior to implementation on the final product. These results are used to provide comprehensive bit cell characterization which can then be compared to device models and adjusted accordingly to provide optimized cell stability versus cell size for a particular technology. The result is designed in reliability which can be accomplished during the early stages of product development.
Partial Support of Meeting of the Board on Mathematical Sciences and Their Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weidman, Scott
2014-08-31
During the performance period, BMSA released the following major reports: Transforming Combustion Research through Cyberinfrastructure (2011); Assessing the Reliability of Complex Models: Mathematical and Statistical Foundations of Verification, Validation, and Uncertainty Quantification (2012); Fueling Innovation and Discovery: The Mathematical Sciences in the 21st Century (2012); Aging and the Macroeconomy: Long-Term Implications of an Older Population (2012); The Mathematical Sciences in 2025 (2013); Frontiers in Massive Data Analysis (2013); and Developing a 21st Century Global Library for Mathematics Research (2014).
Evaluation of short- and long-term complications after endoscopically assisted gastropexy in dogs.
Dujowich, Mauricio; Keller, Mattew E; Reimer, S Brent
2010-01-15
To determine short- and long-term complications in clinically normal dogs after endoscopically assisted gastropexy. Prospective case series. 24 dogs. Endoscopically assisted gastropexy was performed on each dog. Dogs were evaluated laparoscopically at 1 or 6 months after surgery to assess integrity of the gastropexy. Long-term outcome was determined via telephone conversations conducted with owners > or = 1 year after surgery. Mean +/- SD gastropexy length was 4.5 +/- 0.9 cm, and mean duration of surgery was 22 +/- 5 minutes. One dog had a partially rotated stomach at the time of insufflation, which was corrected by untwisting the stomach with Babcock forceps. Two dogs vomited within 4 weeks after surgery, but the vomiting resolved in both dogs. Four dogs had diarrhea within 4 weeks after surgery, which resolved without medical intervention. In all dogs, the gastropexy site was firmly adhered to the abdominal wall at the level of the pyloric antrum. Long-term follow-up information was available for 23 dogs, none of which had any episodes of gastric dilatation-volvulus a mean of 1.4 years after gastropexy. Endoscopically assisted gastropexy can be a simple, fast, safe, and reliable method for performing prophylactic gastropexy in dogs. At 1 and 6 months after gastropexy, adequate placement and adhesion of the gastropexy site to the body wall was confirmed. Such a procedure could maximize the benefits of minimally invasive surgery, such as decreases in morbidity rate and anesthetic time. This technique appeared to be suitable as an alternative to laparoscopic-assisted gastropexy.
NASA Astrophysics Data System (ADS)
Perez-Poch, Antoni; Gonzalez, Daniel
Numerical models and simulations are an emerging area of research in human physiology. As complex numerical models are available, along with high-speed computing technologies, it is possible to produce more accurate predictions of the long-term effects of reduced gravity on the human body. NELME (Numerical Emulation of Long-Term Microgravity Effects) has been developed as an electrical-like control system model of the pysiological changes that may arise when gravity changes are applied to the cardiovascular system. Validation of the model has been carried out in parabolic flights at UPC BarcelonaTech Platform. A number of parabolas of up to 8 seconds were performed at Sabadell Airport with an aerobatic single-engine CAP10B plane capable of performing such maneuvres. Heart rate, arterial pressure, and gravity data was collected and compared to the output obtained from the model in order to optimize its parameters. The model is then able to perform simulations for long-term periods of exposure to microgravity, and then the risk for a major malfunction is evaluated. Vascular resistance is known to be impaired during a long-term mission. This effects are not fully understood, and the model is capable of providing a continuous thread of simulated scenarios, while varying gravity in a nearly-continuous way. Aerobic exercise as countermeasure has been simulated as a periodic perturbation into the simulated physiological system. Results are discussed in terms of the validaty and reliability of the outcomes from the model, that have been found compatible with the available data in the literature. Different gender sensitivities to microgravity exposure are discussed. Also thermal stress along with exercise, as it happens in the case of Extravehicular activity is smulated. Results show that vascular resistance is significantly impared (p<0,05) at gravity levels less than 0,4g, when exposed for a period of time longer than 16 days. This degree of impairement is comparable with that resulting from a microgravity exposure. These results suggest that long-term activities on the surface of Mars may have a greater impact on the cardiovascular health than previously thought.
Ancient Glass: A Literature Search and its Role in Waste Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strachan, Denis M.; Pierce, Eric M.
2010-07-01
When developing a performance assessment model for the long-term disposal of immobilized low-activity waste (ILAW) glass, it is desirable to determine the durability of glass forms over very long periods of time. However, testing is limited to short time spans, so experiments are performed under conditions that accelerate the key geochemical processes that control weathering. Verification that models currently being used can reliably calculate the long term behavior ILAW glass is a key component of the overall PA strategy. Therefore, Pacific Northwest National Laboratory was contracted by Washington River Protection Solutions, LLC to evaluate alternative strategies that can be usedmore » for PA source term model validation. One viable alternative strategy is the use of independent experimental data from archaeological studies of ancient or natural glass contained in the literature. These results represent a potential independent experiment that date back to approximately 3600 years ago or 1600 before the current era (bce) in the case of ancient glass and 106 years or older in the case of natural glass. The results of this literature review suggest that additional experimental data may be needed before the result from archaeological studies can be used as a tool for model validation of glass weathering and more specifically disposal facility performance. This is largely because none of the existing data set contains all of the information required to conduct PA source term calculations. For example, in many cases the sediments surrounding the glass was not collected and analyzed; therefore having the data required to compare computer simulations of concentration flux is not possible. This type of information is important to understanding the element release profile from the glass to the surrounding environment and provides a metric that can be used to calibrate source term models. Although useful, the available literature sources do not contain the required information needed to simulate the long-term performance of nuclear waste glasses in a near-surface or deep geologic repositories. The information that will be required include 1) experimental measurements to quantify the model parameters, 2) detailed analyses of altered glass samples, and 3) detailed analyses of the sediment surrounding the ancient glass samples.« less
Shibata, Satoko; Stegaroiu, Roxana; Nakazawa, Akari; Ohuchi, Akitsugu
2017-03-01
(i) To assess comprehension of oral care-related terms among caregivers and nurses working at long-term care facilities, using a newly developed test; (ii) to analyse the effect of participant characteristics on their comprehension. Effective mutual communication between dental professionals and caregivers/nurses is essential for providing information on daily oral care for institutionalised elders. A 36-item word-knowledge test in Japanese was developed to assess comprehension of oral care-related terms. The test was administered to a convenience sample of 236 nursing staff (198 caregivers and 38 nurses) at six long-term care facilities in Niigata City, Japan, and its reliability and validity were verified. Associations of participant characteristics with their responses were investigated by multiple regression analysis. Mean percentage of correct responses (accuracy rate) for nursing staff was approximately 62% (highest for oral care products and lowest for prosthodontic terms). Test internal reliability was high (Cronbach's alpha >0.8). Concurrent validity (test ability to distinguish between characteristically different groups) was confirmed. Mean accuracy rate was significantly higher among nurses (78.5 ± 19.3%) than among caregivers (58.7 ± 22.8%), and among respondents with interest in oral care (64.2 ± 21.1%) than among those with no such interest (51.5 ± 28.9%). The word-knowledge test was valid and reliable for nursing staff of six long-term care facilities in Niigata City. Their comprehension was low for perioral and intraoral structures, related symptom and disease names, and prosthodontics terms related to oral care. Understanding of oral care-related terms among the nursing staff was related to their occupation and interest in oral care. © 2016 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.
Zhang, Fang; Duan, Xiaohui; Lu, Liejing; Zhang, Xiang; Chen, Meiwei; Mao, Jiaji; Cao, Minghui; Shen, Jun
2017-10-01
Transplantation of neural stem cells (NSCs) is emerging as a new therapeutic approach for stroke. Real-time imaging of transplanted NSCs is essential for successful cell delivery, safety monitoring, tracking cell fate and function, and understanding the interactions of transplanted cells with the host environment. Magnetic resonance imaging (MRI) of magnetic nanoparticle-labeled cells has been the most widely used means to track stem cells in vivo. Nevertheless, it does not allow for the reliable discrimination between live and dead cells. Reporter gene-based MRI was considered as an alternative strategy to overcome this shortcoming. In this work, a class of lentiviral vector-encoding ferritin heavy chain (FTH) and enhanced green fluorescent protein (EGFP) was constructed to deliver reporter genes into NSCs. After these transgenic NSCs were transplanted into the contralateral hemisphere of rats with acute ischemic stroke, MRI and fluorescence imaging (FLI) were performed in vivo for tracking the fate of transplanted cells over a long period of 6 wk. The results demonstrated that the FTH and EGFP can be effectively and safely delivered to NSCs via the designed lentiviral vector. The distribution and migration of grafted stem cells could be monitored by bimodal MRI and FLI. FTH can be used as a robust MRI reporter for reliable reporting of the short-term viability of cell grafts, whereas its capacity for tracking the long-term viability of stem cells remains dependent on several confounding factors such as cell death and the concomitant reactive inflammation.
Stirling engine - Approach for long-term durability assessment
NASA Technical Reports Server (NTRS)
Tong, Michael T.; Bartolotta, Paul A.; Halford, Gary R.; Freed, Alan D.
1992-01-01
The approach employed by NASA Lewis for the long-term durability assessment of the Stirling engine hot-section components is summarized. The approach consists of: preliminary structural assessment; development of a viscoplastic constitutive model to accurately determine material behavior under high-temperature thermomechanical loads; an experimental program to characterize material constants for the viscoplastic constitutive model; finite-element thermal analysis and structural analysis using a viscoplastic constitutive model to obtain stress/strain/temperature at the critical location of the hot-section components for life assessment; and development of a life prediction model applicable for long-term durability assessment at high temperatures. The approach should aid in the provision of long-term structural durability and reliability of Stirling engines.
The vital role of manufacturing quality in the reliability of PV modules
NASA Astrophysics Data System (ADS)
Rusch, Peter
2014-10-01
The influence of manufacturing quality on the reliability of PV modules coming out of today's factories has been, and is still, under estimated among investors and buyers. The main reason is perception. Contrary to popular belief, PV modules are not a commodity. Module quality does differ among module brands. Certification alone does not guarantee the quality or reliability of a module. Cost reductions in manufacturing have unequivocally affected module quality. And the use of new, cheaper materials has had a measureable impact on module reliability. The need for meaningful manufacturing quality standards has been understood by the leading technical institutions and important industry players. The fact that most leading PV panel manufacturers have been certified according to ISO 9001 has led to some level of improvement and higher effectiveness. The new ISO 9001 PV QMS standards will be a major step in providing a tool to assess PV manufacturers' quality management systems. The current lack of sufficient standards has still got a negative influence on the quality of modules being installed today. Today every manufacturer builds their modules in their own way with little standardization or adherence to quality processes and methods, which are commonplace in other manufacturing industries. Although photovoltaic technology is to a great extent mature, the way modules are being produced has changed significantly over the past few years and it continues to change at a rapid pace. Investors, financiers and lenders stand the most to gain from PV systems over the long-term, but also the most to lose. Investors, developers, EPC, O&M and solar asset management companies must all manage manufacturing quality more proactively or they will face unexpected risks and failures down the road. Manufacturing quality deserves more transparency and attention, as it is a major driver of module performance and reliability. This paper will explain the benefits of good manufacturing quality and the dangers in poor manufacturing quality. The paper also explains why buyers and long-term investors need to pay close attention to the day-to-day manufacturing quality of module manufacturers. We demonstrate how these quality risks can be assessed and mitigated by independent diligence, professional contracting and smart quality assurance processes that can be easily built into any module procurement process. We highlight the steps to ensure that every module used in a PV system is built to quality standards that support the long-term reliability of a PV system.
Long life, high speed, thrust-load ball bearings
NASA Technical Reports Server (NTRS)
Signer, H.; Bamberger, E. N.; Zaretsky, E. V.
1975-01-01
Long-term bearing operation at three million DN can be achieved with high degree of reliability using full combination of sophisticated but currently available state-of-the-art bearing materials and designs, lubricants, and lubricating techniques.
The Future of the U.S. Nuclear Weapons Program
NASA Astrophysics Data System (ADS)
Brooks, Linton F.
2007-03-01
This paper will examine our plans for the future of the U.S. nuclear weapons program including efforts to ``transform'' the stockpile and supporting infrastructure. We proceed from the premise that the United States will need a safe, secure, and reliable nuclear deterrent for the foreseeable future. Moreover, the Stockpile Stewardship Program is working. Today's stockpile---comprised of legacy warheads left over from the Cold War---is safe and reliable. That said, we see increased risk, absent nuclear testing, in assuring the long-term safety and reliability of our current stockpile. Nor is today's nuclear weapons complex sufficiently ``responsive'' to fixing technical problems in the stockpile, or to potential adverse geopolitical change. Our task is to work to ensure that the U.S. nuclear weapons enterprise, including the stockpile and supporting infrastructure, meets long-term national security needs. Our approach is to develop and field replacement warheads for the legacy stockpile---so-called Reliable Replacement Warheads (RRW)---as a means to transform both the nuclear stockpile and supporting infrastructure.
Huang, Lijie; Huang, Taicheng; Zhen, Zonglei; Liu, Jia
2016-03-15
We present a test-retest dataset for evaluation of long-term reliability of measures from structural and resting-state functional magnetic resonance imaging (sMRI and rfMRI) scans. The repeated scan dataset was collected from 61 healthy adults in two sessions using highly similar imaging parameters at an interval of 103-189 days. However, as the imaging parameters were not completely identical, the reliability estimated from this dataset shall reflect the lower bounds of the true reliability of sMRI/rfMRI measures. Furthermore, in conjunction with other test-retest datasets, our dataset may help explore the impact of different imaging parameters on reliability of sMRI/rfMRI measures, which is especially critical for assessing datasets collected from multiple centers. In addition, intelligence quotient (IQ) was measured for each participant using Raven's Advanced Progressive Matrices. The data can thus be used for purposes other than assessing reliability of sMRI/rfMRI alone. For example, data from each single session could be used to associate structural and functional measures of the brain with the IQ metrics to explore brain-IQ association.
Theodore J. Weller; Shawn C. Thomas; James A. Baldwin
2014-01-01
The advent of broad-scale threats to bats such as white-nose syndrome and climate change highlights the need for reliable baseline assessment of their populations. However, few long-term, rigorously designed assessments of bat populations exist, particularly in western North America. Consequently, results of informal monitoring efforts are often the only data available...
Devendra Amatya; S. Tian; Z. Dai; Ge Sun
2016-01-01
A reliable estimate of potential evapotranspiration (PET) for a forest ecosystem is critical in ecohydrologic modeling related with water supply, vegetation dynamics, and climate change and yet is a challenging task due to its complexity. Based on long-term on-site measured hydro-climatic data and predictions from earlier validated hydrologic modeling studies...
Salmi, T; Sovijärvi, A R; Brander, P; Piirilä, P
1988-11-01
Reliable long-term assessment of cough is necessary in many clinical and scientific settings. A new method for long-term recording and automatic analysis of cough is presented. The method is based on simultaneous recording of two independent signals: high-pass filtered cough sounds and cough-induced fast movements of the body. The acoustic signals are recorded with a dynamic microphone in the acoustic focus of a glass fiber paraboloid mirror. Body movements are recorded with a static charge-sensitive bed located under an ordinary plastic foam mattress. The patient can be studied lying or sitting with no transducers or electrodes attached. A microcomputer is used for sampling of signals, detection of cough, statistical analyses, and on-line printing of results. The method was validated in seven adult patients with a total of 809 spontaneous cough events, using clinical observation as a reference. The sensitivity of the method to detect cough was 99.0 percent, and the positive predictivity was 98.1 percent. The system ignored speaking and snoring. The method provides a convenient means of reliable long-term follow-up of cough in clinical work and research.
Long-term decoding of movement force and direction with a wireless myoelectric implant.
Morel, Pierre; Ferrea, Enrico; Taghizadeh-Sarshouri, Bahareh; Audí, Josep Marcel Cardona; Ruff, Roman; Hoffmann, Klaus-Peter; Lewis, Sören; Russold, Michael; Dietl, Hans; Abu-Saleh, Lait; Schroeder, Dietmar; Krautschneider, Wolfgang; Meiners, Thomas; Gail, Alexander
2016-02-01
The ease of use and number of degrees of freedom of current myoelectric hand prostheses is limited by the information content and reliability of the surface electromyography (sEMG) signals used to control them. For example, cross-talk limits the capacity to pick up signals from small or deep muscles, such as the forearm muscles for distal arm amputations, or sites of targeted muscle reinnervation (TMR) for proximal amputations. Here we test if signals recorded from the fully implanted, induction-powered wireless Myoplant system allow long-term decoding of continuous as well as discrete movement parameters with better reliability than equivalent sEMG recordings. The Myoplant system uses a centralized implant to transmit broadband EMG activity from four distributed bipolar epimysial electrodes. Two Rhesus macaques received implants in their backs, while electrodes were placed in their upper arm. One of the monkeys was trained to do a cursor task via a haptic robot, allowing us to control the forces exerted by the animal during arm movements. The second animal was trained to perform a center-out reaching task on a touchscreen. We compared the implanted system with concurrent sEMG recordings by evaluating our ability to decode time-varying force in one animal and discrete reach directions in the other from multiple features extracted from the raw EMG signals. In both cases, data from the implant allowed a decoder trained with data from a single day to maintain an accurate decoding performance during the following months, which was not the case for concurrent surface EMG recordings conducted simultaneously over the same muscles. These results show that a fully implantable, centralized wireless EMG system is particularly suited for long-term stable decoding of dynamic movements in demanding applications such as advanced forelimb prosthetics in a wide range of configurations (distal amputations, TMR).
Long-term decoding of movement force and direction with a wireless myoelectric implant
NASA Astrophysics Data System (ADS)
Morel, Pierre; Ferrea, Enrico; Taghizadeh-Sarshouri, Bahareh; Marcel Cardona Audí, Josep; Ruff, Roman; Hoffmann, Klaus-Peter; Lewis, Sören; Russold, Michael; Dietl, Hans; Abu-Saleh, Lait; Schroeder, Dietmar; Krautschneider, Wolfgang; Meiners, Thomas; Gail, Alexander
2016-02-01
Objective. The ease of use and number of degrees of freedom of current myoelectric hand prostheses is limited by the information content and reliability of the surface electromyography (sEMG) signals used to control them. For example, cross-talk limits the capacity to pick up signals from small or deep muscles, such as the forearm muscles for distal arm amputations, or sites of targeted muscle reinnervation (TMR) for proximal amputations. Here we test if signals recorded from the fully implanted, induction-powered wireless Myoplant system allow long-term decoding of continuous as well as discrete movement parameters with better reliability than equivalent sEMG recordings. The Myoplant system uses a centralized implant to transmit broadband EMG activity from four distributed bipolar epimysial electrodes. Approach. Two Rhesus macaques received implants in their backs, while electrodes were placed in their upper arm. One of the monkeys was trained to do a cursor task via a haptic robot, allowing us to control the forces exerted by the animal during arm movements. The second animal was trained to perform a center-out reaching task on a touchscreen. We compared the implanted system with concurrent sEMG recordings by evaluating our ability to decode time-varying force in one animal and discrete reach directions in the other from multiple features extracted from the raw EMG signals. Main results. In both cases, data from the implant allowed a decoder trained with data from a single day to maintain an accurate decoding performance during the following months, which was not the case for concurrent surface EMG recordings conducted simultaneously over the same muscles. Significance. These results show that a fully implantable, centralized wireless EMG system is particularly suited for long-term stable decoding of dynamic movements in demanding applications such as advanced forelimb prosthetics in a wide range of configurations (distal amputations, TMR).
Markowska, A L; Breckler, S J
1999-12-01
The goal of the current project is to develop a multivariate statistical strategy for the formation of behavioral indices of performance and, further, to apply this strategy to establish the relationship between age and important characteristics of performance. The strategy was to begin with a large set of measures that span a broad range of behaviors. The behavioral effects of the following variables were examined: Age (4, 12, 24, and 30 months), genotype [Fischer 344 and a hybrid (F1) of Fischer 344 and Brown Norway (F344xBN)], gender (Fischer 344 males and Fischer 344 females), long-term diet (ad lib diet or dietary restriction beginning at 4 months of age), and short-term diet (ad lib diet or dietary restriction during testing). The behavioral measures were grouped into conceptually related indicators. The indicators within a set were submitted to a principal component analysis to help identify the summary indices of performance, which were formed with the assumption that these component scores would offer more reliable and valid measures of relevant aspects of behavioral performance than would individual measures taken alone. In summary, this approach has made a number of important contributions. It has provided sensitive and selective measures of performance that indicated contributions of all variables: psychological process, age, genotype, gender, long-term and short-term diet and has increased the sensitivity of behavioral measures to age-related behavioral impairment. It has also improved task-manageability by decreasing the number of meaningful variables without losing important information, consequently providing a simplification of the pattern of changes.
Development of new EVA formulations for improved performance at NREL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pern, F.J.
1997-02-01
We review in chronological order the research stages and fundamental concepts involved in developing modified and new EVA formulations for improved performance against photo-induced degradation and discoloration. The new NREL EVA formulations use additives totally different from the present commercial formulations (EVA A9918 and EVA 15295). Validation of their long-term photostability and thermostability is presently under way. Together with UV-absorbing glass superstrates, they may offer better success in achieving a more reliable module performance and longer service life without significant EVA discoloration problems, which are commonly experienced with EVA A9918 and, at a lesser rate, EVA 15295. {copyright} {ital 1997more » American Institute of Physics.}« less
Stefan, H; Kreiselmeyer, G; Kasper, B; Graf, W; Pauli, E; Kurzbuch, K; Hopfengärtner, R
2011-03-01
A reliable method for the estimation of seizure frequency and severity is indispensable in assessing the efficacy of drug treatment in epilepsies. These quantities are usually deduced from subjective patient reports, which may cause considerable problems due to insufficient or false descriptions of seizures and their frequency. We present data from two difficult-to-treat patients with intractable epilepsy. Pat. 1 has had an unknown number of CP seizures. Here, a prolonged outpatient video-EEG monitoring over 160 h and 137 h (over an interval of three months) was performed with an automated seizure detection method. Pat. 2 suffered exclusively from nocturnal seizures originating from the frontal lobe. In this case, an objective quantification of the efficacy of drug treatment over a time period of 22 weeks was established. For the reliable quantification of seizures, a prolonged outpatient video/video-EEG monitoring was appended after a short-term inpatient monitoring period. Patient 1: The seizure detection algorithm was capable of detecting 10 out of 11 seizures. The number of false-positive events was <0.03/h. It was clearly demonstrated that the patient showed more seizures than originally reported. Patient 2: The add-on medication of lacosamide led to a significant reduction in seizure frequency and to a marked decrease in the mean duration of seizures. The severity of seizures was reduced from numerous hypermotoric seizures to few mild, head-turning seizures. Outpatient monitoring may be helpful to guide treatment for severe epilepsies and offers the possibility to more reliably quantify the efficacy of treatment in the long-term, even over several months. Copyright © 2010 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Weed, M R; Taffe, M A; Polis, I; Roberts, A C; Robbins, T W; Koob, G F; Bloom, F E; Gold, L H
1999-10-25
A computerized behavioral battery based upon human neuropsychological tests (CANTAB, CeNeS, Cambridge, UK) has been developed to assess cognitive behaviors of rhesus monkeys. Monkeys reliably performed multiple tasks, providing long-term assessment of changes in a number of behaviors for a given animal. The overall goal of the test battery is to characterize changes in cognitive behaviors following central nervous system (CNS) manipulations. The battery addresses memory (delayed non-matching to sample, DNMS; spatial working memory, using a self-ordered spatial search task, SOSS), attention (intra-/extra-dimensional shift, ID/ED), motivation (progressive-ratio, PR), reaction time (RT) and motor coordination (bimanual task). As with human neuropsychological batteries, different tasks are thought to involve different neural substrates, and therefore performance profiles should assess function in particular brain regions. Monkeys were tested in transport cages, and responding on a touch sensitive computer monitor was maintained by food reinforcement. Parametric manipulations of several tasks demonstrated the sensitivity of performance to increases in task difficulty. Furthermore, the factors influencing difficulty for rhesus monkeys were the same as those shown to affect human performance. Data from this study represent performance of a population of healthy normal monkeys that will be used for comparison in subsequent studies of performance following CNS manipulations such as infection with simian immunodeficiency virus (NeuroAIDS) or drug administration.
Ultra Reliable Closed Loop Life Support for Long Space Missions
NASA Technical Reports Server (NTRS)
Jones, Harry W.; Ewert, Michael K.
2010-01-01
Spacecraft human life support systems can achieve ultra reliability by providing sufficient spares to replace all failed components. The additional mass of spares for ultra reliability is approximately equal to the original system mass, provided that the original system reliability is not too low. Acceptable reliability can be achieved for the Space Shuttle and Space Station by preventive maintenance and by replacing failed units. However, on-demand maintenance and repair requires a logistics supply chain in place to provide the needed spares. In contrast, a Mars or other long space mission must take along all the needed spares, since resupply is not possible. Long missions must achieve ultra reliability, a very low failure rate per hour, since they will take years rather than weeks and cannot be cut short if a failure occurs. Also, distant missions have a much higher mass launch cost per kilogram than near-Earth missions. Achieving ultra reliable spacecraft life support systems with acceptable mass will require a well-planned and extensive development effort. Analysis must determine the reliability requirement and allocate it to subsystems and components. Ultra reliability requires reducing the intrinsic failure causes, providing spares to replace failed components and having "graceful" failure modes. Technologies, components, and materials must be selected and designed for high reliability. Long duration testing is needed to confirm very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The system must be designed, developed, integrated, and tested with system reliability in mind. Maintenance and reparability of failed units must not add to the probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass should start soon since it must be a long term effort.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Hai; Spencer, Benjamin W.; Cai, Guowei
Concrete is widely used in the construction of nuclear facilities because of its structural strength and its ability to shield radiation. The use of concrete in nuclear power plants for containment and shielding of radiation and radioactive materials has made its performance crucial for the safe operation of the facility. As such, when life extension is considered for nuclear power plants, it is critical to have accurate and reliable predictive tools to address concerns related to various aging processes of concrete structures and the capacity of structures subjected to age-related degradation. The goal of this report is to document themore » progress of the development and implementation of a fully coupled thermo-hydro-mechanical-chemical model in GRIZZLY code with the ultimate goal to reliably simulate and predict long-term performance and response of aged NPP concrete structures subjected to a number of aging mechanisms including external chemical attacks and volume-changing chemical reactions within concrete structures induced by alkali-silica reactions and long-term exposure to irradiation. Based on a number of survey reports of concrete aging mechanisms relevant to nuclear power plants and recommendations from researchers in concrete community, we’ve implemented three modules during FY15 in GRIZZLY code, (1) multi-species reactive diffusion model within cement materials; (2) coupled moisture and heat transfer model in concrete; and (3) anisotropic, stress-dependent, alkali-silica reaction induced swelling model. The multi-species reactive diffusion model was implemented with the objective to model aging of concrete structures subjected to aggressive external chemical attacks (e.g., chloride attack, sulfate attack, etc.). It considers multiple processes relevant to external chemical attacks such as diffusion of ions in aqueous phase within pore spaces, equilibrium chemical speciation reactions and kinetic mineral dissolution/precipitation. The moisture/heat transfer module was implemented to simulate long-term spatial and temporal evolutions of the moisture and temperature fields within concrete structures at both room and elevated temperatures. The ASR swelling model implemented in GRIZZLY code can simulate anisotropic expansions of ASR gel under either uniaxial, biaxial and triaxial stress states, and can be run simultaneously with the moisture/heat transfer model and coupled with various elastic/inelastic solid mechanics models that were implemented in GRIZZLY code previously. This report provides detailed descriptions of the governing equations, constitutive equations and numerical algorithms of the three modules implemented in GRIZZLY during FY15, simulation results of example problems and model validation results by comparing simulations with available experimental data reported in the literature. The close match between the experiments and simulations clearly demonstrate the potential of GRIZZLY code for reliable evaluation and prediction of long-term performance and response of aged concrete structures in nuclear power plants.« less
Assessing the implementation of bias correction in the climate prediction
NASA Astrophysics Data System (ADS)
Nadrah Aqilah Tukimat, Nurul
2018-04-01
An issue of the climate changes nowadays becomes trigger and irregular. The increment of the greenhouse gases (GHGs) emission into the atmospheric system day by day gives huge impact to the fluctuated weather and global warming. It becomes significant to analyse the changes of climate parameters in the long term. However, the accuracy in the climate simulation is always be questioned to control the reliability of the projection results. Thus, the Linear Scaling (LS) as a bias correction method (BC) had been applied to treat the gaps between observed and simulated results. About two rainfall stations were selected in Pahang state there are Station Lubuk Paku and Station Temerloh. Statistical Downscaling Model (SDSM) used to perform the relationship between local weather and atmospheric parameters in projecting the long term rainfall trend. The result revealed the LS was successfully to reduce the error up to 3% and produced better climate simulated results.
Mars transit vehicle thermal protection system: Issues, options, and trades
NASA Technical Reports Server (NTRS)
Brown, Norman
1986-01-01
A Mars mission is characterized by different mission phases. The thermal control of cryogenic propellant in a propulsive vehicle must withstand the different mission environments. Long term cryogenic storage may be achieved by passive or active systems. Passive cryo boiloff management features will include multilayer insulation, vapor cooled shield, and low conductance structural supports and penetrations. Active boiloff management incorporates the use of a refrigeration system. Key system trade areas include active verses passive system boiloff management (with respect to safety, reliability, and cost) and propellant tank insulation optimizations. Technology requirements include refrigeration technology advancements, insulation performance during long exposure, and cryogenic fluid transfer system for mission vehicle propellant tanking during vehicle buildip in LEO.
NASA Astrophysics Data System (ADS)
Kazaroff, John M.
1993-02-01
Lewis Research Center is developing broad-based new technologies for space chemical engines to satisfy long-term needs of ETO launch vehicles and other vehicles operating in and beyond Earth orbit. Specific objectives are focused on high performance LO2/LH2 engines providing moderate thrusts of 7,5-200 klb. This effort encompasses research related to design analysis and manufacturing processes needed to apply advanced materials to subcomponents, components, and subsystems of space-based systems and related ground-support equipment. High-performance space-based chemical engines face a number of technical challenges. Liquid hydrogen turbopump impellers are often so large that they cannot be machined from a single piece, yet high stress at the vane/shroud interface makes bonding extremely difficult. Tolerances on fillets are critical on large impellers. Advanced materials and fabricating techniques are needed to address these and other issues of interest. Turbopump bearings are needed which can provide reliable, long life operation at high speed and high load with low friction losses. Hydrostatic bearings provide good performance, but transients during pump starts and stops may be an issue because no pressurized fluid is available unless a separate bearing pressurization system is included. Durable materials and/or coatings are needed that can demonstrate low wear in the harsh LO2/LH2 environment. Advanced materials are also needed to improve the lifetime, reliability and performance of other propulsion system elements such as seals and chambers.
Valentine, William J; Pollock, Richard F; Saunders, Rhodri; Bae, Jay; Norrbacka, Kirsi; Boye, Kristina
Recent publications describing long-term follow-up from landmark trials and diabetes registries represent an opportunity to revisit modeling options in type 1 diabetes mellitus (T1DM). To develop a new product-independent model capable of predicting long-term clinical and cost outcomes. After a systematic literature review to identify clinical trial and registry data, a model was developed (the PRIME Diabetes Model) to simulate T1DM progression and complication onset. The model runs as a patient-level simulation, making use of covariance matrices for cohort generation and risk factor progression, and simulating myocardial infarction, stroke, angina, heart failure, nephropathy, retinopathy, macular edema, neuropathy, amputation, hypoglycemia, ketoacidosis, mortality, and risk factor evolution. Several approaches novel to T1DM modeling were used, including patient characteristics and risk factor covariance, a glycated hemoglobin progression model derived from patient-level data, and model averaging approaches to evaluate complication risk. Validation analyses comparing modeled outcomes with published studies demonstrated that the PRIME Diabetes Model projects long-term patient outcomes consistent with those reported for a number of long-term studies. Macrovascular end points were reliably reproduced across five different populations and microvascular complication risk was accurately predicted on the basis of comparisons with landmark studies and published registry data. The PRIME Diabetes Model is product-independent, available online, and has been developed in line with good practice guidelines. Validation has indicated that outcomes from long-term studies can be reliably reproduced. The model offers new approaches to long-standing challenges in diabetes modeling and may become a valuable tool for informing health care policy. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Development of ultracapacitor modules for 42-V automotive electrical systems
NASA Astrophysics Data System (ADS)
Jung, Do Yang; Kim, Young Ho; Kim, Sun Wook; Lee, Suck-Hyun
Two types of ultracapacitor modules have been developed for use as energy-storage devices for 42-V systems in automobiles. The modules show high performance and good reliability in terms of discharge and recharge capability, long-term endurance, and high energy and power. During a 42-V system simulation test of 6-kW power boosting/regenerative braking, the modules demonstrate very good performance. In high-power applications such as 42-V and hybrid vehicle systems, ultracapacitors have many merits compared with batteries, especially with respect to specific power at high rate, thermal stability, charge-discharge efficiency, and cycle-life. Ultracapacitors are also very safe, reliable and environmentally friendly. The cost of ultracapacitors is still high compared with batteries because of the low production scale, but is decreasing very rapidly. It is estimated that the cost of ultracapacitors will decrease to US$ 300 per 42-V module in the near future. Also, the maintenance cost of the ultracapacitor is nearly zero because of its high cycle-life. Therefore, the combined cost of the capacitor and maintenance will be lower than that of batteries in the near future. Overall, comparing performance, price and other parameters of ultracapacitors with batteries, ultracapacitors are the most likely candidate for energy-storage in 42-V systems.
A Comparison of Long- vs. Short-Term Recall of Substance Use and HIV Risk Behaviors.
Janssen, Tim; Braciszewski, Jordan M; Vose-O'Neal, Adam; Stout, Robert L
2017-05-01
The Timeline Follow-back (TLFB) questionnaire has become a pre-eminent tool in substance use and human immunodeficiency virus (HIV) risk research, allowing researchers to assess fine-grained changes in risk behavior over long periods. However, data on accuracy of recall over long (12-month) periods are sparse, especially combined data on HIV risk and substance use from post-treatment samples. Studies on the development of substance use and HIV risk stand to benefit from data on the accurate recall of such behavior over longer retroactive spans of time. The present study offers data on the test-retest reliability of current TLFB assessment versus 6- and 12-month delayed TLFB assessment, using a post-treatment sample (n = 50). Long-term reliability of TLFB data on HIV risk was predominantly good to excellent, with 13 of 20 assessed variables in that range. TLFB data on substance use was similar, with 22 of 26 variables resulting in good/excellent reliability. Our findings support the notion that, notable exceptions aside, the TLFB may be effectively used to assess retroactive HIV risk and substance use in periods of 12 months.
Developing Sustainable Life Support System Concepts
NASA Technical Reports Server (NTRS)
Thomas, Evan A.
2010-01-01
Sustainable spacecraft life support concepts may allow the development of more reliable technologies for long duration space missions. Currently, life support technologies at different levels of development are not well evaluated against each other, and evaluation methods do not account for long term reliability and sustainability of the hardware. This paper presents point-of-departure sustainability evaluation criteria for life support systems, that may allow more robust technology development, testing and comparison. An example sustainable water recovery system concept is presented.
Review of magnetostrictive vibration energy harvesters
NASA Astrophysics Data System (ADS)
Deng, Zhangxian; Dapino, Marcelo J.
2017-10-01
The field of energy harvesting has grown concurrently with the rapid development of portable and wireless electronics in which reliable and long-lasting power sources are required. Electrochemical batteries have a limited lifespan and require periodic recharging. In contrast, vibration energy harvesters can supply uninterrupted power by scavenging useful electrical energy from ambient structural vibrations. This article reviews the current state of vibration energy harvesters based on magnetostrictive materials, especially Terfenol-D and Galfenol. Existing magnetostrictive harvester designs are compared in terms of various performance metrics. Advanced techniques that can reduce device size and improve performance are presented. Models for magnetostrictive devices are summarized to guide future harvester designs.
New getter configuration at wafer level for assuring long term stability of MEMs
NASA Astrophysics Data System (ADS)
Moraja, Marco; Amiotti, Marco; Kullberg, Richard C.
2003-01-01
The evolution from ceramic packages to wafer to wafer hermetic sealing poses tremendous technical challenges to integrate a proper getter inside the MEMs to assure a long term stability and reliability of the devices. The state of the art solution to integrate a getter inside the MEMs of the last generation consists in patterning the getter material with a specific geometry onto the Si cap wafer. The practical implementation of this solution consists in a 4" or 6" Si wafers with grooves or particular incisures, where the getter material is placed in form of a thick film. The typical thickness of these thick films is in the range of few microns, depending on the gas load to be handled during the lifetime of the device. The structure of the thick getter film is highly porous in order to improve sorption performances, but at the same time there are no loose particles thanks to a proprietary manufacturing method. The getter thick film is composed of a Zr special alloy with a proper composition to optimize the sorption performances. The getter thick film can be placed selectively into grooves without affecting the lateral regions, surrounding the grooves where the hermetic sealing is performed.
75 FR 32209 - North San Pablo Bay Restoration and Reuse Project
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-07
... Napa counties are facing long-term water supply shortfalls. Surface and groundwater supplies within... water levels and water quality. Recycled water can augment local water supplies on a regional basis... reliability. Additionally, reliable water supply is needed in order to continue the restoration of tidal...
Temporal reliability and lateralization of the resting-state language network.
Zhu, Linlin; Fan, Yang; Zou, Qihong; Wang, Jue; Gao, Jia-Hong; Niu, Zhendong
2014-01-01
The neural processing loop of language is complex but highly associated with Broca's and Wernicke's areas. The left dominance of these two areas was the earliest observation of brain asymmetry. It was demonstrated that the language network and its functional asymmetry during resting state were reproducible across institutions. However, the temporal reliability of resting-state language network and its functional asymmetry are still short of knowledge. In this study, we established a seed-based resting-state functional connectivity analysis of language network with seed regions located at Broca's and Wernicke's areas, and investigated temporal reliability of language network and its functional asymmetry. The language network was found to be temporally reliable in both short- and long-term. In the aspect of functional asymmetry, the Broca's area was found to be left lateralized, while the Wernicke's area is mainly right lateralized. Functional asymmetry of these two areas revealed high short- and long-term reliability as well. In addition, the impact of global signal regression (GSR) on reliability of the resting-state language network was investigated, and our results demonstrated that GSR had negligible effect on the temporal reliability of the resting-state language network. Our study provided methodology basis for future cross-culture and clinical researches of resting-state language network and suggested priority of adopting seed-based functional connectivity for its high reliability.
Temporal Reliability and Lateralization of the Resting-State Language Network
Zou, Qihong; Wang, Jue; Gao, Jia-Hong; Niu, Zhendong
2014-01-01
The neural processing loop of language is complex but highly associated with Broca's and Wernicke's areas. The left dominance of these two areas was the earliest observation of brain asymmetry. It was demonstrated that the language network and its functional asymmetry during resting state were reproducible across institutions. However, the temporal reliability of resting-state language network and its functional asymmetry are still short of knowledge. In this study, we established a seed-based resting-state functional connectivity analysis of language network with seed regions located at Broca's and Wernicke's areas, and investigated temporal reliability of language network and its functional asymmetry. The language network was found to be temporally reliable in both short- and long-term. In the aspect of functional asymmetry, the Broca's area was found to be left lateralized, while the Wernicke's area is mainly right lateralized. Functional asymmetry of these two areas revealed high short- and long-term reliability as well. In addition, the impact of global signal regression (GSR) on reliability of the resting-state language network was investigated, and our results demonstrated that GSR had negligible effect on the temporal reliability of the resting-state language network. Our study provided methodology basis for future cross-culture and clinical researches of resting-state language network and suggested priority of adopting seed-based functional connectivity for its high reliability. PMID:24475058
NASA Astrophysics Data System (ADS)
Lemehov, S. E.; Sobolev, V. P.; Verwerft, M.
2011-09-01
The European Facility for Industrial Transmutation (EFIT) of the minor actinides (MA), from LWR spent fuel is being developed in the integrated project EUROTRANS within the 6th Framework Program of EURATOM. Two composite uranium-free fuel systems, containing a large fraction of MA, are proposed as the main candidates: a CERCER with magnesia matrix hosting (Pu,MA)O 2-x particles, and a CERMET with metallic molybdenum matrix. The long-term thermal and mechanical behaviour of the fuel under the expected EFIT operating conditions is one of the critical issues in the core design. To make a reliable prediction of long-term thermo-mechanical behaviour of the hottest fuel rods in the lead-cooled version of EFIT with thermal power of 400 MW, different fuel performance codes have been used. This study describes the main results of modelling the thermo-mechanical behaviour of the hottest CERCER fuel rods with the fuel performance code MACROS which indicate that the CERCER fuel residence time can safely reach at least 4-5 effective full power years.
Liquefaction for cataract extraction
Labiris, Georgios; Toli, Aspasia; Polychroni, Damaskini; Gkika, Maria; Angelonias, Dimitrios; Kozobolis, Vassilios P.
2016-01-01
A systematic review of the recent literature regarding the implementation of the liquefaction in cataract surgery and its short-term and long-term outcomes in various parameters that affect the quality of patients' life, including visual rehabilitation and possible complications was performed based on the PubMed, Medline, Nature and the American Academy of Ophthalmology databases in November 2013 and data from 14 comparative studies were included in this narrative review. Liquefaction is an innovative technology for cataract extraction that uses micropulses of balanced salt solution to liquefy the lens nucleus. Most studies reported that liquefaction is a reliable technology for mild to moderate cataracts, while fragmentation difficulties may be encountered with harder nuclei. PMID:26949656
Yusifov, Rashad
2018-01-01
Abstract For routine behavioral tasks, mice predominantly rely on olfactory cues and tactile information. In contrast, their visual capabilities appear rather restricted, raising the question whether they can improve if vision gets more behaviorally relevant. We therefore performed long-term training using the visual water task (VWT): adult standard cage (SC)-raised mice were trained to swim toward a rewarded grating stimulus so that using visual information avoided excessive swimming toward nonrewarded stimuli. Indeed, and in contrast to old mice raised in a generally enriched environment (Greifzu et al., 2016), long-term VWT training increased visual acuity (VA) on average by more than 30% to 0.82 cycles per degree (cyc/deg). In an individual animal, VA even increased to 1.49 cyc/deg, i.e., beyond the rat range of VAs. Since visual experience enhances the spatial frequency threshold of the optomotor (OPT) reflex of the open eye after monocular deprivation (MD), we also quantified monocular vision after VWT training. Monocular VA did not increase reliably, and eye reopening did not initiate a decline to pre-MD values as observed by optomotry; VA values rather increased by continued VWT training. Thus, optomotry and VWT measure different parameters of mouse spatial vision. Finally, we tested whether long-term MD induced ocular dominance (OD) plasticity in the visual cortex of adult [postnatal day (P)162–P182] SC-raised mice. This was indeed the case: 40–50 days of MD induced OD shifts toward the open eye in both VWT-trained and, surprisingly, also in age-matched mice without VWT training. These data indicate that (1) long-term VWT training increases adult mouse VA, and (2) long-term MD induces OD shifts also in adult SC-raised mice. PMID:29379877
Naveh, Sivan; Perlman, Gidon Y; Elitsur, Yair; Planer, David; Gilon, Dan; Leibowitz, David; Lotan, Chaim; Danenberg, Haim; Alcalai, Ronny
2017-02-01
Conduction disorders requiring permanent pacemaker (PPM) implantation are a known complication of transcatheter aortic valve implantation (TAVI). Indications for permanent pacing in this setting are still controversial. The study aim was to characterize the natural history of conduction disorders related to TAVI, and to identify predictors for long-term pacing dependency. Consecutive patients who underwent TAVI were included in this prospective observational study. The conduction system was investigated by reviewing 12-lead ECGs during hospitalization and up to 1-year follow-up and by analyzing pacemaker interrogation data. Multivariate analysis was performed in order to identify independent predictors for pacemaker dependency. Of 110 patients included in the analysis, 38 (34.5%) underwent PPM implantation. Of those, 26 (68.4%) had a long-term pacing dependency (required PPM), while 12 (31.6%) did not (not-required PPM). Logistic regression revealed that baseline RBBB (P = 0.01, OR = 18.0), baseline PR interval (P = 0.019, OR = 1.14), post-TAVI PR interval and the change in PR interval from baseline (P < 0.001 for both, OR = 1.17 for each 10 milliseconds increment) were independent predictors for long-term pacing dependency. A PR interval increment of greater than 28 milliseconds had the best accuracy in predicting pacemaker dependency. Increased pre- and postprocedural PR intervals and pre-existing RBBB are reliable predictors for long-term PPM dependency, while left bundle branch block or QRS width are misleading factors. Our study suggests that the decision for implanting PPM after TAVI should be based mostly on the prolongation of the PR interval. © 2016 Wiley Periodicals, Inc.
Sekiyama, Juliana Y; Camargo, Cintia Z; Eduardo, Luís; Andrade, C; Kayser, Cristiane
2013-11-01
To analyze the diagnostic performance and reliability of different parameters evaluated by widefield nailfold capillaroscopy (NFC) with those obtained by video capillaroscopy in patients with Raynaud’s phenomenon (RP). Two hundred fifty-two individuals were assessed, including 101 systemic sclerosis (SSc; scleroderma) patients,61 patients with undifferentiated connective tissue disease, 37 patients with primary RP, and 53 controls. Widefield NFC was performed using a stereomicroscope under 10–25 x magnification and direct measurement of all parameters. Video capillaroscopy was performed under 200 x magnification, with the acquirement of 32 images per individual (4 fields per finger in 8 fingers). The following parameters were analyzed in 8 fingers of the hands (excluding thumbs) by both methods: number of capillaries/mm, number of enlarged and giant capillaries, microhemorrhages, and avascular score.Intra- and interobserver reliability was evaluated by performing both examinations in 20 individuals on 2 different days and by 2 long-term experienced observers. There was a significant correlation (P < 0.000) between widefield NFC and video capillaroscopy in the comparison of all parameters. Kappa values and intraclass correlation coefficient analysis showed excellent intra- and interobserver reproducibility for all parameters evaluated by widefield NFC and video capillaroscopy. Bland-Altman analysis showed high agreement of all parameters evaluated in both methods. According to receiver operating characteristic curve analysis, both methods showed a similar performance in discriminating SSc patients from controls. Widefield NFC and video capillaroscopy are reliable and accurate methods and can be used equally for assessing peripheral microangiopathy in RP and SSc patients. Nonetheless, the high reliability obtained may not be similar for less experienced examiners.
Rohani, Pejman; King, Aaron A.
2010-01-01
Infectious diseases have been a prime testing ground for ecological theory. At the same time, the ecological perspective is increasingly recognized as essential in epidemiology. Long-term, spatially-resolved, reliable disease incidence data and the ability to confront them with mechanistic models have been critical in this cross-fertilization. Here, we review some of the key intellectual developments in epidemiology facilitated by long-term data. We proceed to identify research frontiers at the interface of ecology and epidemiology and their associated data needs. PMID:20800928
NASA Astrophysics Data System (ADS)
Wu, Zhiyong (Richard)
Motivated by the overall challenge of ensuring long-term sustainable electricity service, we view this challenge as a long-term decision making problem under uncertainties. We start by recognizing that, independent of the industry organization, the uncertainties are enormous and often exogenous to the energy service providers. They are multi-dimensional and are result of fundamental drivers, ranging from the supply side, through the demand side, to the regulatory and policy sides. The basic contribution of this thesis comes from the recognition that long-term investments for ensuring reliable and stable electricity service critically depend on how these uncertainties are perceived, valued and managed by the different stakeholders within the complex industry organization such as the electric power industry. We explain several reasons why price signals obtained from current short-term electricity markets alone are not sufficient enough for long-term sustainable provision. Some enhancements are presented in the thesis to improve the short-term electricity market price signals to reflect the true cost of operation. New market mechanisms and instruments are needed to facilitate the stakeholders to better deal with long-term risks. The problems of ensuring long-term stable reliable service in the sense of the traditional resource adequacy requirements are revisited in both the restructuring industry and regulated industry. We introduce a so-called Stratum Electricity Market (SEM) design as the basic market mechanism for solving the problem of long-term reliable electricity service through a series of interactive multi-lateral market exchange platforms for risks communication, management and evaluations over various time horizons and by the different groups of stakeholders. In other words, our proposed SEM is a basic IT-enabled framework for the decision making processes by various parties over different time. Because of the uniqueness of electricity as a commodity, the values for the same amount of energy during different time and at different location can vary dramatically. Moreover, for the same hour, the values for the same amount of power at base load level or at peak load level are different due to the different generation technologies and other non-convex constraints like unit commitment. The multiple market products at zonal/nodal levels with different time horizon and time of use categories are designed to reflect more realistic demand and supply conditions at various temporal and spatial granularities. Detailed market rules, rights and regulations (3Rs) concerning the sub-markets interactions, product hierarchy and financial settlements are also examined.
Long-term lumen depreciation behavior and failure modes of multi-die array LEDs
NASA Astrophysics Data System (ADS)
Jayawardena, Asiri; Marcus, Daniel; Prugue, Ximena; Narendran, Nadarajah
2013-09-01
One of the main advantages of multi-die array light-emitting diodes (LEDs) is their high flux density. However, a challenge for using such a product in lighting fixture applications is the heat density and the need for thermal management to keep the junction temperatures of all the dies low for long-term reliable performance. Ten multi-die LED array samples for each product from four different manufacturers were subjected to lumen maintenance testing (as described in IES-LM-80-08), and their resulting lumen depreciation and failure modes were studied. The products were tested at the maximum case (or pin) temperature reported by the respective manufacturer by appropriately powering the LEDs. In addition, three samples for each product from two different manufacturers were subjected to rapid thermal cycling, and the resulting lumen depreciation and failure modes were studied. The results showed that the exponential lumen decay model using long-term lumen maintenance data as recommended in IES TM-21 does not fit for all package types. The failure of a string of dies and single die failure in a string were observed in some of the packages.
National Space Transportation System (NSTS) technology needs
NASA Technical Reports Server (NTRS)
Winterhalter, David L.; Ulrich, Kimberly K.
1990-01-01
The National Space Transportation System (NSTS) is one of the Nation's most valuable resources, providing manned transportation to and from space in support of payloads and scientific research. The NSTS program is currently faced with the problem of hardware obsolescence, which could result in unacceptable schedule and cost impacts to the flight program. Obsolescence problems occur because certain components are no longer being manufactured or repair turnaround time is excessive. In order to achieve a long-term, reliable transportation system that can support manned access to space through 2010 and beyond, NASA must develop a strategic plan for a phased implementation of enhancements which will satisfy this long-term goal. The NSTS program has initiated the Assured Shuttle Availability (ASA) project with the following objectives: eliminate hardware obsolescence in critical areas, increase reliability and safety of the vehicle, decrease operational costs and turnaround time, and improve operational capability. The strategy for ASA will be to first meet the mandatory needs - keep the Shuttle flying. Non-mandatory changes that will improve operational capability and enhance performance will then be considered if funding is adequate. Upgrade packages should be developed to install within designated inspection periods, grouped in a systematic approach to reduce cost and schedule impacts, and allow the capability to provide a Block 2 Shuttle (Phase 3).
Kennerly, Susan; Heggestad, Eric D; Myers, Haley; Yap, Tracey L
2015-07-29
An effective workforce performing within the context of a positive cultural environment is central to a healthcare organization's ability to achieve quality outcomes. The Nursing Culture Assessment Tool (NCAT) provides nurses with a valid and reliable tool that captures the general aspects of nursing culture. This study extends earlier work confirming the tool's construct validity and dimensionality by standardizing the scoring approach and establishing norm-referenced scoring. Scoring standardization provides a reliable point of comparison for NCAT users. NCAT assessments support nursing's ability to evaluate nursing culture, use results to shape the culture into one that supports change, and advance nursing's best practices and care outcomes. Registered nurses, licensed practical nurses, and certified nursing assistants from 54 long-term care facilities in Kentucky, Nevada, North Carolina, and Oregon were surveyed. Confirmatory factor analysis yielded six first order factors forming the NCAT's subscales (Expectations, Behaviors, Teamwork, Communication, Satisfaction, Commitment) (Comparative Fit Index 0.93) and a second order factor-The Total Culture Score. Aggregated facility level comparisons of observed group variance with expected random variance using rwg(J) statistics is presented. Normative scores and cumulative rank percentages and how the NCAT can be used in implementing planned change are provided.
NASA Astrophysics Data System (ADS)
Luchner, Jakob; Anghileri, Daniela; Castelletti, Andrea
2017-04-01
Real-time control of multi-purpose reservoirs can benefit significantly from hydro-meteorological forecast products. Because of their reliability, the most used forecasts range on time scales from hours to few days and are suitable for short-term operation targets such as flood control. In recent years, hydro-meteorological forecasts have become more accurate and reliable on longer time scales, which are more relevant to long-term reservoir operation targets such as water supply. While the forecast quality of such products has been studied extensively, the forecast value, i.e. the operational effectiveness of using forecasts to support water management, has been only relatively explored. It is comparatively easy to identify the most effective forecasting information needed to design reservoir operation rules for flood control but it is not straightforward to identify which forecast variable and lead time is needed to define effective hedging rules for operational targets with slow dynamics such as water supply. The task is even more complex when multiple targets, with diverse slow and fast dynamics, are considered at the same time. In these cases, the relative importance of different pieces of information, e.g. magnitude and timing of peak flow rate and accumulated inflow on different time lags, may vary depending on the season or the hydrological conditions. In this work, we analyze the relationship between operational forecast value and streamflow forecast horizon for different multi-purpose reservoir trade-offs. We use the Information Selection and Assessment (ISA) framework to identify the most effective forecast variables and horizons for informing multi-objective reservoir operation over short- and long-term temporal scales. The ISA framework is an automatic iterative procedure to discriminate the information with the highest potential to improve multi-objective reservoir operating performance. Forecast variables and horizons are selected using a feature selection technique. The technique determines the most informative combination in a multi-variate regression model to the optimal reservoir releases based on perfect information at a fixed objective trade-off. The improved reservoir operation is evaluated against optimal reservoir operation conditioned upon perfect information on future disturbances and basic reservoir operation using only the day of the year and the reservoir level. Different objective trade-offs are selected for analyzing resulting differences in improved reservoir operation and selected forecast variables and horizons. For comparison, the effective streamflow forecast horizon determined by the ISA framework is benchmarked against the performances obtained with a deterministic model predictive control (MPC) optimization scheme. Both the ISA framework and the MPC optimization scheme are applied to the real-world case study of Lake Como, Italy, using perfect streamflow forecast information. The principal operation targets for Lake Como are flood control and downstream water supply which makes its operation a suitable case study. Results provide critical feedback to reservoir operators on the use of long-term streamflow forecasts and to the hydro-meteorological forecasting community with respect to the forecast horizon needed from reliable streamflow forecasts.
2012-01-01
Background Aims of the present study are the following: 1. to describe the rationale and methodology of the Services and Health for Elderly in Long TERm care (SHELTER) study, a project funded by the European Union, aimed at implementing the interRAI instrument for Long Term Care Facilities (interRAI LTCF) as a tool to assess and gather uniform information about nursing home (NH) residents across different health systems in European countries; 2. to present the results about the test-retest and inter-rater reliability of the interRAI LTCF instrument translated into the languages of participating countries; 3 to illustrate the characteristics of NH residents at study entry. Methods A 12 months prospective cohort study was conducted in 57 NH in 7 EU countries (Czech Republic, England, Finland, France, Germany, Italy, The Netherlands) and 1 non EU country (Israel). Weighted kappa coefficients were used to evaluate the reliability of interRAI LTCF items. Results Mean age of 4156 residents entering the study was 83.4 ± 9.4 years, 73% were female. ADL disability and cognitive impairment was observed in 81.3% and 68.0% of residents, respectively. Clinical complexity of residents was confirmed by a high prevalence of behavioral symptoms (27.5% of residents), falls (18.6%), pressure ulcers (10.4%), pain (36.0%) and urinary incontinence (73.5%). Overall, 197 of the 198 the items tested met or exceeded standard cut-offs for acceptable test-retest and inter-rater reliability after translation into the target languages. Conclusion The interRAI LTCF appears to be a reliable instrument. It enables the creation of databases that can be used to govern the provision of long-term care across different health systems in Europe, to answer relevant research and policy questions and to compare characteristics of NH residents across countries, languages and cultures. PMID:22230771
Tracking wildlife by satellite: Current systems and performance
Harris, Richard B.; Fancy, Steven G.; Douglas, David C.; Garner, Gerald W.; Amstrup, Steven C.; McCabe, Thomas R.; Pank, Larry F.
1990-01-01
Since 1984, the U.S. Fish and Wildlife Service has used the Argos Data Collection and Location System (DCLS) and Tiros-N series satellites to monitor movements and activities of 10 species of large mammals in Alaska and the Rocky Mountain region. Reliability of the entire system was generally high. Data were received from instrumented caribou (Rangifer tarandus) during 91% of 318 possible transmitter-months. Transmitters failed prematurely on 5 of 45 caribou, 2 of 6 muskoxen (Ovibos moschatus), and 1 of 2 gray wolves (Canis lupus). Failure rates were considerably higher for polar (Ursus maritimus) and brown (U. arctos) bears than for caribou (Rangifer tarandus). Efficiency of gathering both locational and sensor data was related to both latitude and topography.Mean error of locations was estimated to be 954 m (median = 543 m) for transmitters on captive animals; 90% of locations were <1,732 m from the true location. Argos's new location class zero processing provided many more locations than normal processing, but mean location error was much higher than locations estimated normally. Locations were biased when animals were at elevations other than those used in Argos's calculations.Long-term and short-term indices of animal activity were developed and evaluated. For several species, the long-term index was correlated with movement patterns and the short-term index was calibrated to specific activity categories (e.g., lying, feeding, walking).Data processing and sampling considerations were evaluated. Algorithms for choosing the most reliable among a series of reported locations were investigated. Applications of satellite telemetry data and problems with lack of independence among locations are discussed.
Hotol and Saenger are good political trump cards
NASA Astrophysics Data System (ADS)
Ruppe, Harry O.
Political and technological aspects of proposals for ESA reusable and/or SSTO launch vehicles (LVs) are examined in a critical review. The lack of reliable performance and cost estimates for such unconventional LV designs as Hotol, Saenger II, LART, ADV, and EARL is pointed out, and it is argued that progress toward the ESA goal of greater European space autonomy could be seriously endangered by abandoning or underfunding the current Ariane/Hermes LV program. The cost and reliability of expendable and reusable LV systems are discussed; two-stage and hybrid air-breathing engine concepts are compared; and the need for fundamental in-depth planning studies based on presently available technology or realistic projections is stressed. Long-term funding of such research at about 5 percent of present Ariane/Hermes levels is recommended.
Perceptual and Acoustic Analyses of Good Voice Quality in Male Radio Performers.
Warhurst, Samantha; Madill, Catherine; McCabe, Patricia; Ternström, Sten; Yiu, Edwin; Heard, Robert
2017-03-01
Good voice quality is an asset to professional voice users, including radio performers. We examined whether (1) voices could be reliably categorized as good for the radio and (2) these categories could be predicted using acoustic measures. Male radio performers (n = 24) and age-matched male controls performed "The Rainbow Passage" as if presenting on the radio. Voice samples were rated using a three-stage paired-comparison paradigm by 51 naive listeners and perceptual categories were identified (Study 1), and then analyzed for fundamental frequency, long-term average spectrum, cepstral peak prominence, and pause or spoken-phrase duration (Study 2). Study 1: Good inter-judge reliability was found for perceptual judgments of the best 15 voices (good for radio category, 14/15 = radio performers), but agreement on the remaining 33 voices (unranked category) was poor. Study 2: Discriminant function analyses showed that the SD standard deviation of sounded portion duration, equivalent sound level, and smoothed cepstral peak prominence predicted membership of categories with moderate accuracy (R 2 = 0.328). Radio performers are heterogeneous for voice quality; good voice quality was judged reliably in only 14 out of 24 radio performers. Current acoustic analyses detected some of the relevant signal properties that were salient in these judgments. More refined perceptual analysis and the use of other perceptual methods might provide more information on the complex nature of judging good voices. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lu, Mengqian; Lall, Upmanu; Robertson, Andrew W.; Cook, Edward
2017-03-01
Streamflow forecasts at multiple time scales provide a new opportunity for reservoir management to address competing objectives. Market instruments such as forward contracts with specified reliability are considered as a tool that may help address the perceived risk associated with the use of such forecasts in lieu of traditional operation and allocation strategies. A water allocation process that enables multiple contracts for water supply and hydropower production with different durations, while maintaining a prescribed level of flood risk reduction, is presented. The allocation process is supported by an optimization model that considers multitime scale ensemble forecasts of monthly streamflow and flood volume over the upcoming season and year, the desired reliability and pricing of proposed contracts for hydropower and water supply. It solves for the size of contracts at each reliability level that can be allocated for each future period, while meeting target end of period reservoir storage with a prescribed reliability. The contracts may be insurable, given that their reliability is verified through retrospective modeling. The process can allow reservoir operators to overcome their concerns as to the appropriate skill of probabilistic forecasts, while providing water users with short-term and long-term guarantees as to how much water or energy they may be allocated. An application of the optimization model to the Bhakra Dam, India, provides an illustration of the process. The issues of forecast skill and contract performance are examined. A field engagement of the idea is useful to develop a real-world perspective and needs a suitable institutional environment.
Changes in School Climate in a Long-Term Perspective
ERIC Educational Resources Information Center
Kallestad, Jan Helge
2010-01-01
In a previous report five school climate instruments were explored (1983 and 1985), and four scales were regarded as meaningful climate measures according to suggested criteria. These scales were re-inspected in the present study (1997 and 1998) by analyses of internal consistency, estimates of reliability (unit and aggregated reliability), and…
A real-time measurement system for long-life flood monitoring and warning applications.
Marin-Perez, Rafael; García-Pintado, Javier; Gómez, Antonio Skarmeta
2012-01-01
A flood warning system incorporates telemetered rainfall and flow/water level data measured at various locations in the catchment area. Real-time accurate data collection is required for this use, and sensor networks improve the system capabilities. However, existing sensor nodes struggle to satisfy the hydrological requirements in terms of autonomy, sensor hardware compatibility, reliability and long-range communication. We describe the design and development of a real-time measurement system for flood monitoring, and its deployment in a flash-flood prone 650 km(2) semiarid watershed in Southern Spain. A developed low-power and long-range communication device, so-called DatalogV1, provides automatic data gathering and reliable transmission. DatalogV1 incorporates self-monitoring for adapting measurement schedules for consumption management and to capture events of interest. Two tests are used to assess the success of the development. The results show an autonomous and robust monitoring system for long-term collection of water level data in many sparse locations during flood events.
A Real-Time Measurement System for Long-Life Flood Monitoring and Warning Applications
Marin-Perez, Rafael; García-Pintado, Javier; Gómez, Antonio Skarmeta
2012-01-01
A flood warning system incorporates telemetered rainfall and flow/water level data measured at various locations in the catchment area. Real-time accurate data collection is required for this use, and sensor networks improve the system capabilities. However, existing sensor nodes struggle to satisfy the hydrological requirements in terms of autonomy, sensor hardware compatibility, reliability and long-range communication. We describe the design and development of a real-time measurement system for flood monitoring, and its deployment in a flash-flood prone 650 km2 semiarid watershed in Southern Spain. A developed low-power and long-range communication device, so-called DatalogV1, provides automatic data gathering and reliable transmission. DatalogV1 incorporates self-monitoring for adapting measurement schedules for consumption management and to capture events of interest. Two tests are used to assess the success of the development. The results show an autonomous and robust monitoring system for long-term collection of water level data in many sparse locations during flood events. PMID:22666028
Unified pre- and postsynaptic long-term plasticity enables reliable and flexible learning.
Costa, Rui Ponte; Froemke, Robert C; Sjöström, P Jesper; van Rossum, Mark Cw
2015-08-26
Although it is well known that long-term synaptic plasticity can be expressed both pre- and postsynaptically, the functional consequences of this arrangement have remained elusive. We show that spike-timing-dependent plasticity with both pre- and postsynaptic expression develops receptive fields with reduced variability and improved discriminability compared to postsynaptic plasticity alone. These long-term modifications in receptive field statistics match recent sensory perception experiments. Moreover, learning with this form of plasticity leaves a hidden postsynaptic memory trace that enables fast relearning of previously stored information, providing a cellular substrate for memory savings. Our results reveal essential roles for presynaptic plasticity that are missed when only postsynaptic expression of long-term plasticity is considered, and suggest an experience-dependent distribution of pre- and postsynaptic strength changes.
An algorithmic interactive planning framework in support of sustainable technologies
NASA Astrophysics Data System (ADS)
Prica, Marija D.
This thesis addresses the difficult problem of generation expansion planning that employs the most effective technologies in today's changing electric energy industry. The electrical energy industry, in both the industrialized world and in developing countries, is experiencing transformation in a number of different ways. This transformation is driven by major technological breakthroughs (such as the influx of unconventional smaller-scale resources), by industry restructuring, changing environmental objectives, and the ultimate threat of resource scarcity. This thesis proposes a possible planning framework in support of sustainable technologies where sustainability is viewed as a mix of multiple attributes ranging from reliability and environmental impact to short- and long-term efficiency. The idea of centralized peak-load pricing, which accounts for the tradeoffs between cumulative operational effects and the cost of new investments, is the key concept in support of long-term planning in the changing industry. To start with, an interactive planning framework for generation expansion is posed as a distributed decision-making model. In order to reconcile the distributed sub-objectives of different decision makers with system-wide sustainability objectives, a new concept of distributed interactive peak load pricing is proposed. To be able to make the right decisions, the decision makers must have sufficient information about the estimated long-term electricity prices. The sub-objectives of power plant owners and load-serving entities are profit maximization. Optimized long-term expansion plans based on predicted electricity prices are communicated to the system-wide planning authority as long-run bids. The long-term expansion bids are cleared by the coordinating planner so that the system-wide long-term performance criteria are satisfied. The interactions between generation owners and the coordinating planning authority are repeated annually. We view the proposed interactive planning framework as a necessary paradigm for planning in the changing industry where choice must be reconciled with societal public objectives.
Evaluation and Validation of Organic Materials for Advanced Stirling Convertors (ASCs): Overview
NASA Technical Reports Server (NTRS)
Shin, Euy-Sik Eugene
2015-01-01
Various organic materials are used as essential parts in Stirling Convertors for their unique properties and functionalities such as bonding, potting, sealing, thread locking, insulation, and lubrication. More efficient Advanced Stirling Convertors (ASC) are being developed for future space applications especially with a long mission cycle, sometimes up to 17 years, such as deep space exploration or lunar surface power or Mars rovers, and others. Thus, performance, durability, and reliability of those organics should be critically evaluated in every possible material-process-fabrication-service environment relations based on their mission specifications. In general, thermal stability, radiation hardness, outgassing, and material compatibility of the selected organics have been systematically evaluated while their process and fabrication conditions and procedures were being optimized. Service environment-simulated long term aging tests up to 4 years were performed as a function of temperature for durability assessment of the most critical organic material systems.
Performance of Superconducting Current Feeder System for SST-1
NASA Astrophysics Data System (ADS)
Garg, A.; Nimavat, H.; Shah, P.; Patel, K.; Sonara, D.; Srikanth, G. L. N.; Bairagi, N.; Christian, D.; Patel, R.; Mahesuria, G.; Panchal, R.; Panchal, P.; Sharma, R.; Purwar, G.; Singh, G. K.; Tanna, V. L.; Pradhan, S.
2017-02-01
Superconducting (SC) Current Feeder System (CFS) for SST-1 (Steady state superconducting Tokamak was installed and commissioned in 2012. Since then, it has been operating successfully in successive plasma campaigns. The aim of this system is to transfer electric current from power supply at ambient temperature to SC magnets which are at 4.5 K. It consists of 10 kA vapour cooled current leads, Nb-Ti/Cu bus-bars, liquid nitrogen cooled radiation shield and liquid/vapour helium circuits. This system had been operated reliably in different scenario such as initial cool- down, electric current (ramp-up, ramp down and long-time steady state condition), cold with no current and in quench etc. In addition to this, it has fulfilled the long term operation with SST-1 with current flat top of 4.7 kA for more than 20,000 seconds. This paper highlights operational performance along with results in different aspects.
Reliable video transmission over fading channels via channel state estimation
NASA Astrophysics Data System (ADS)
Kumwilaisak, Wuttipong; Kim, JongWon; Kuo, C.-C. Jay
2000-04-01
Transmission of continuous media such as video over time- varying wireless communication channels can benefit from the use of adaptation techniques in both source and channel coding. An adaptive feedback-based wireless video transmission scheme is investigated in this research with special emphasis on feedback-based adaptation. To be more specific, an interactive adaptive transmission scheme is developed by letting the receiver estimate the channel state information and send it back to the transmitter. By utilizing the feedback information, the transmitter is capable of adapting the level of protection by changing the flexible RCPC (rate-compatible punctured convolutional) code ratio depending on the instantaneous channel condition. The wireless channel is modeled as a fading channel, where the long-term and short- term fading effects are modeled as the log-normal fading and the Rayleigh flat fading, respectively. Then, its state (mainly the long term fading portion) is tracked and predicted by using an adaptive LMS (least mean squares) algorithm. By utilizing the delayed feedback on the channel condition, the adaptation performance of the proposed scheme is first evaluated in terms of the error probability and the throughput. It is then extended to incorporate variable size packets of ITU-T H.263+ video with the error resilience option. Finally, the end-to-end performance of wireless video transmission is compared against several non-adaptive protection schemes.
Durability, value, and reliability of selected electric powered wheelchairs.
Fass, Megan V; Cooper, Rory A; Fitzgerald, Shirley G; Schmeler, Mark; Boninger, Michael L; Algood, S David; Ammer, William A; Rentschler, Andrew J; Duncan, John
2004-05-01
To compare the durability, value, and reliability of selected electric powered wheelchairs (EPWs), purchased in 1998. Engineering standards tests of quality and performance. A rehabilitation engineering center. Fifteen EPWs: 3 each of the Jazzy, Quickie, Lancer, Arrow, and Chairman models. Not applicable. Wheelchairs were evaluated for durability (lifespan), value (durability, cost), and reliability (rate of repairs) using 2-drum and curb-drop machines in accordance with the standards of the American National Standards Institute and Rehabilitation Engineering and Assistive Technology Society of North America. The 5 brands differed significantly (P
Cements and adhesives for all-ceramic restorations.
Manso, Adriana P; Silva, Nelson R F A; Bonfante, Estevam A; Pegoraro, Thiago A; Dias, Renata A; Carvalho, Ricardo M
2011-04-01
Dental cements are designed to retain restorations, prefabricated or cast posts and cores, and appliances in a stable, and long-lasting position in the oral environment. Resin-based cements were developed to overcome drawbacks of nonresinous materials, including low strength, high solubility, and opacity. Successful cementation of esthetic restorations depends on appropriate treatment to the tooth substrate and intaglio surface of the restoration, which in turn, depends on the ceramic characteristics. A reliable resin cementation procedure can only be achieved if the operator is aware of the mechanisms involved to perform the cementation and material properties. This article addresses current knowledge of resin cementation concepts, exploring the bonding mechanisms that influence long-term clinical success of all-ceramic systems. Copyright © 2011 Elsevier Inc. All rights reserved.
Reliability of ultra-thin insulation coatings for long-term electrophysiological recordings
NASA Astrophysics Data System (ADS)
Hooker, S. A.
2006-03-01
Improved measurement of neural signals is needed for research into Alzheimer's, Parkinson's, epilepsy, strokes, and spinal cord injuries. At the heart of such instruments are microelectrodes that measure electrical signals in the body. Such electrodes must be small, stable, biocompatible, and robust. However, it is also important that they be easily implanted without causing substantial damage to surrounding tissue. Tissue damage can lead to the generation of immune responses that can interfere with the electrical measurement, preventing long-term recording. Recent advances in microfabrication and nanotechnology afford the opportunity to dramatically reduce the physical dimensions of recording electrodes, thereby minimizing insertion damage. However, one potential cause for concern is the reliability of the insulating coatings, applied to these ultra-fine-diameter wires to precisely control impedance. Such coatings are often polymeric and are applied everywhere but the sharpened tips of the wires, resulting in nominal impedances between 0.5 MOhms and 2.0 MOhms. However, during operation, the polymer degrades, changing the exposed area and the impedance. In this work, ultra-thin ceramic coatings were deposited as an alternative to polymer coatings. Processing conditions were varied to determine the effect of microstructure on measurement stability during two-electrode measurements in a standard buffer solution. Coatings were applied to seven different metals to determine any differences in performance due to the surface characteristics of the underlying wire. Sintering temperature and wire type had significant effects on coating degradation. Dielectric breakdown was also observed at relatively low voltages, indicating that test conditions must be carefully controlled to maximize reliability.
NASA Astrophysics Data System (ADS)
Friedenauer, Axel; Karpov, Vladimir; Wei, Daoping; Hager, Manfred; Ernstberger, Bernhard; Clements, Wallace R. L.; Kaenders, Wilhelm G.
2012-07-01
Large telescopes equipped with adaptive optics require 20-25W CW 589-nm sources with emission linewidths of ~5 MHz. These Guide Star (GS) lasers should also be highly reliable and simple to operate and maintain for many years at the top of a mountain facility. Under contract from ESO, industrial partners TOPTICA and MPBC are nearing completion of the development of GS lasers for the ESO VLT, with delivery of the first of four units scheduled for December 2012. We report on the design and performance of the fully-engineered Pre-Production Unit (PPU), including system reliability/availability analysis, the successfully-concluded qualification testing, long-term component and system level tests and long-term maintenance and support planning. The chosen approach is based on ESO's patented narrow-band Raman Fiber Amplifier (EFRA) technology. A master oscillator signal from a linearly-polarized TOPTICA 20-mW, 1178-nm CW diode laser, with stabilized emission frequency and controllable linewidth up to a few MHz, is amplified in an MPBC polarization-maintaining (PM) RFA pumped by a high-power 1120-nm PM fiber laser. With efficient stimulated Brillouin scattering suppression, an unprecedented 40W of narrow-band RFA output has been obtained. This is then mode-matched into a resonant-cavity doubler with a free-spectral-range matching the sodium D2a to D2b separation, allowing simultaneous generation of an additional frequency component (D2b line) to re-pump the sodium atom electronic population. With this technique, the return flux can be increased without having to resort to electro-optical modulators and without the risk of introducing optical wave front distortions. The demonstrated output powers with doubling efficiencies >80% at 589 nm easily exceed the 20W design goal and require less than 700 W of electrical power. In summary, the fiber-based guide star lasers provide excellent beam quality and are modular, turn-key, maintenance-free, reliable, efficient, and ruggedized devices whose compactness allows installation directly onto the launch telescope structure.
Reliability Quantification of the Flexure: A Critical Stirling Convertor Component
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Korovaichuk, Igor; Zampino, Edward J.
2004-01-01
Uncertainties in the manufacturing, fabrication process, material behavior, loads, and boundary conditions results in the variation of the stresses and strains induced in the flexures and its fatigue life. Past experience and the test data at material coupon levels revealed a significant amount of scatter of the fatigue life. Owing to these facts, the design of the flexure, using conventional approaches based on safety factor or traditional reliability based on similar equipment considerations does not provide a direct measure of reliability. Additionally, it may not be feasible to run actual long term fatigue tests due to cost and time constraints. Therefore it is difficult to ascertain material fatigue strength limit. The objective of the paper is to present a methodology and quantified results of numerical simulation for the reliability of flexures used in the Stirling convertor for their structural performance. The proposed approach is based on application of finite element analysis method in combination with the random fatigue limit model, which includes uncertainties in material fatigue life. Additionally, sensitivity of fatigue life reliability to the design variables is quantified and its use to develop guidelines to improve design, manufacturing, quality control and inspection design process is described.
Renewal of the Control System and Reliable Long Term Operation of the LHD Cryogenic System
NASA Astrophysics Data System (ADS)
Mito, T.; Iwamoto, A.; Oba, K.; Takami, S.; Moriuchi, S.; Imagawa, S.; Takahata, K.; Yamada, S.; Yanagi, N.; Hamaguchi, S.; Kishida, F.; Nakashima, T.
The Large Helical Device (LHD) is a heliotron-type fusion plasma experimental machine which consists of a fully superconducting magnet system cooled by a helium refrigerator having a total equivalent cooling capacity of 9.2 kW@4.4 K. Seventeenplasma experimental campaigns have been performed successfully since1997 with high reliability of 99%. However, sixteen years have passed from the beginning of the system operation. Improvements are being implementedto prevent serious failures and to pursue further reliability.The LHD cryogenic control system was designed and developed as an open system utilizing latest control equipment of VME controllers and UNIX workstations at the construction time. Howeverthe generation change of control equipment has been advanced. Down-sizing of control deviceshas beenplanned from VME controllers to compact PCI controllers in order to simplify the system configuration and to improve the system reliability. The new system is composed of compact PCI controller and remote I/O connected with EtherNet/IP. Making the system redundant becomes possible by doubling CPU, LAN, and remote I/O respectively. The smooth renewal of the LHD cryogenic controlsystem and the further improvement of the cryogenic system reliability are reported.
Space-based observatories providing key data for climate change applications
NASA Astrophysics Data System (ADS)
Lecomte, J.; Juillet, J. J.
2016-12-01
The Sentinel-1 & 3 mission are part of the Copernicus program, previously known as GMES (Global Monitoring for Environment and Security), whose overall objective is to support Europe's goals regarding sustainable development and global governance of the environment by providing timely and quality data, information, services and knowledge. This European Earth Observation program is led by the European Commission and the space infrastructure is developed under the European Space Agency leadership. Many services will be developed through the Copernicus program among different thematic areas. The climate change is one of this thematic area and the Sentinel-1 & 3 satellites will provide key space-based observations in this area. The Sentinel-1 mission is based on a constellation of 2 identical satellites each one embarking C-SAR Instrument and provides capability for continuous radar mapping of the Earth with enhanced revisit frequency, coverage, timeliness and reliability for operational services and applications requiring long time series. In particular, Sentinel 1 provides all-weather, day-and-night estimates of soil moisture, wind speed and direction, sea ice, continental ice sheets and glaciers. The Sentinel-3 mission will mainly be devoted to the provision of Ocean observation data in routine, long term (20 years of operations) and continuous fashion with a consistent quality and a very high level of availability. Among these data, very accurate surface temperatures and topography measurements will be provided and will constitute key indicators, once ingested in climate change models, for identifying climate drivers and expected climate impacts. The paper will briefly recall the satellite architectures, their main characteristics and performance. The inflight performance and key features of their images or data of the 3 satellites namely Sentinel 1A, 1B and 3A will be reviewed to demonstrate the quality and high scientific potential of the data as well as their availability to the user community. The short, medium and long term will be described. The first satellites are now in operation in orbit. Long-term plan foresees 2 add't recurrent satellites currently under prod, then a new gen in long term. Long term is crucial for climate change analysis & forecast, which is the goal of the Copernicus program.
Teixeira Martins, Marcia C; Jaceldo-Siegl, Karen; Fan, Jing; Singh, Pramil; Fraser, Gary E
2015-01-01
Past dietary patterns may be more important than recent dietary patterns in the aetiology of chronic diseases because of the long latency in their development. We developed an instrument to recall vegetarian dietary patterns during the lifetime and examined its reliability of recall over 5·3 and 32·6 years on average. The short-term/5-year recall ability study (5-RAS) was done using 24 690 participants from the cohort of the Adventist Health Study-2 (mean age 62·2 years). The long-term/33-year recall ability study (33-RAS) included an overlap population of 1721 individuals who joined the Adventist Health Study-1 and Adventist Health Study-2 (mean age 72·5 years). Spearman correlation coefficients for recall of vegetarian status were 0·78 and 0·72 for the 5-RAS and 33-RAS, respectively, when compared with 'reference' data. For both time periods sensitivity and positive predictive values were highest for the lacto-ovo-vegetarian and non-vegetarian patterns (vegans, lacto-ovo-vegetarians, pesco-vegetarians, semi-vegetarians and non-vegetarians). In the 5-RAS analyses, male, non-black, younger, and more educated participants, lifetime Adventists, and those with more stability of consumption of animal products generally showed higher recall ability. Somewhat similar tendencies were shown for the 33-RAS analyses. Our findings show that the instrument has higher reliability for recalled lacto-ovo-vegetarian and non-vegetarian than for vegan, semi- and pesco-vegetarian dietary patterns in both short- and long-term recalls. This is in part because these last dietary patterns were greatly contaminated by recalls that correctly would have belonged in the adjoining category that consumed more animal products.
Long-term associative learning predicts verbal short-term memory performance.
Jones, Gary; Macken, Bill
2018-02-01
Studies using tests such as digit span and nonword repetition have implicated short-term memory across a range of developmental domains. Such tests ostensibly assess specialized processes for the short-term manipulation and maintenance of information that are often argued to enable long-term learning. However, there is considerable evidence for an influence of long-term linguistic learning on performance in short-term memory tasks that brings into question the role of a specialized short-term memory system separate from long-term knowledge. Using natural language corpora, we show experimentally and computationally that performance on three widely used measures of short-term memory (digit span, nonword repetition, and sentence recall) can be predicted from simple associative learning operating on the linguistic environment to which a typical child may have been exposed. The findings support the broad view that short-term verbal memory performance reflects the application of long-term language knowledge to the experimental setting.
Application of Mössbauer spectroscopy on corrosion products of NPP
NASA Astrophysics Data System (ADS)
Dekan, J.; Lipka, J.; Slugeň, V.
2013-04-01
Steam generator (SG) is generally one of the most important components at all nuclear power plants (NPP) with close impact to safe and long-term operation. Material degradation and corrosion/erosion processes are serious risks for long-term reliable operation. Steam generators of four VVER-440 units at nuclear power plants V-1 and V-2 in Jaslovske Bohunice (Slovakia) were gradually changed by new original "Bohunice" design in period 1994-1998, in order to improve corrosion resistance of SGs. Corrosion processes before and after these design and material changes in Bohunice secondary circuit were studied using Mössbauer spectroscopy during last 25 years. Innovations in the feed water pipeline design as well as material composition improvements were evaluated positively. Mössbauer spectroscopy studies of phase composition of corrosion products were performed on real specimens scrapped from water pipelines or in form of filters deposits. Newest results in our long-term corrosion study confirm good operational experiences and suitable chemical regimes (reduction environment) which results mostly in creation of magnetite (on the level 70 % or higher) and small portions of hematite, goethite or hydrooxides. Regular observation of corrosion/erosion processes is essential for keeping NPP operation on high safety level. The output from performed material analyses influences the optimisation of operating chemical regimes and it can be used in optimisation of regimes at decontamination and passivation of pipelines or secondary circuit components. It can be concluded that a longer passivation time leads more to magnetite fraction in the corrosion products composition.
3-D ICs as a Platform for IoT Devices
2017-03-01
small footprint, integrate disparate technologies, and require long term sustainability (extremely low power or self powered). The 3-D structure exhibits...proof, corrosion may slowly degrade the structure of the device, affecting long term reliability. Mechanical stress can also ruin the device due to...substrate vias (TSVs). The TSVs are short vertical in- terconnections (typically 20 µm in length and 2 to 4 µm in diameter [3]) that carry a variety of
The interplay between academic performance and quality of life among preclinical students.
Shareef, Mohammad Abrar; AlAmodi, Abdulhadi A; Al-Khateeb, Abdulrahman A; Abudan, Zainab; Alkhani, Mohammed A; Zebian, Sanderlla I; Qannita, Ahmed S; Tabrizi, Mariam J
2015-10-31
The high academic performance of medical students greatly influences their professional competence in long term career. Meanwhile, medical students greatly demand procuring a good quality of life that can help them sustain their medical career. This study examines validity and reliability of the tool among preclinical students and testifies the influence of their scholastic performance along with gender and academic year on their quality of life. A cross sectional study was conducted by distributing World Health Organization Quality of Life, WHOQOL-BREF, survey among medical students of year one to three at Alfaisal University. For validity, item discriminate validity(IDV) and confirmatory factor analysis were measured and for reliability, Cronbach's α test and internal item consistency(IIC) were examined. The association of GPA, gender and academic year with all major domains was drawn using Pearson's correlation, independent samples t-test and one-way ANOVA, respectively. A total of 335 preclinical students have responded to this questionnaire. The construct has demonstrated an adequate validity and good reliability. The high academic performance of students positively correlated with physical (r = 0.23, p < 0.001), psychological health (r = 0.29, p < 0.001), social relations (r = 0.11, p = 0.03) and environment (r = 0.23, p < 0.001). Male student scored higher than female peers in physical and psychological health. This study has identified a direct relationship between the academic performance of preclinical students and their quality of life. The WHOQOL-BREF is a valid and reliable tool among preclinical students and the positive direction of high academic performance with greater QOL suggests that academic achievers procure higher satisfaction and poor achievers need a special attention for the improvement of their quality of life.
Long-Term Cognitive Outcome and Brain Imaging in Adults After Extracorporeal Membrane Oxygenation.
von Bahr, Viktor; Kalzén, Håkan; Hultman, Jan; Frenckner, Björn; Andersson, Christin; Mosskin, Mikael; Eksborg, Staffan; Holzgraefe, Bernhard
2018-05-01
To investigate the presence of cognitive dysfunction and brain lesions in long-term survivors after treatment with extracorporeal membrane oxygenation for severe respiratory failure, and to see whether patients with prolonged hypoxemia were at increased risk. A single-center retrospective cohort study. Tertiary referral center for extracorporeal membrane oxygenation in Sweden. Long-term survivors treated between 1995 and July 2009. Seven patients from a previously published study investigated with a similar protocol were included. Brain imaging, neurocognitive testing, interview. Thirty-eight patients (i.e., n = 31 + 7) were enrolled and investigated in median 9.0 years after discharge. Only memory tests were performed in 10 patients, mainly due to a lack of formal education necessary for the test results to be reliable. Median full-scale intelligence quotient, memory index, and executive index were 97, 101, and 104, respectively (normal, 100 ± 15). Cognitive function was not reduced in the group with prolonged hypoxemia. Brain imaging showed cerebrovascular lesions in 14 of 38 patients (37%), most commonly in the group treated with venoarterial extracorporeal membrane oxygenation (7/11, 64%). In this group, memory function and executive function were significantly reduced. Patients treated with extracorporeal membrane oxygenation for respiratory failure may have normal cognitive function years after treatment, if not affected by cerebrovascular lesions. Permissive hypoxemia was not correlated with long-term cognitive dysfunction in the present study. Further prospective studies with minimal loss to follow-up are direly needed to confirm our findings.
Chemistry and combustion of fit-for-purpose biofuels.
Rothamer, David A; Donohue, Timothy J
2013-06-01
From the inception of internal combustion engines, biologically derived fuels (biofuels) have played a role. Nicolaus Otto ran a predecessor to today's spark-ignition engine with an ethanol fuel blend in 1860. At the 1900 Paris world's fair, Rudolf Diesel ran his engine on peanut oil. Over 100 years of petroleum production has led to consistency and reliability of engines that demand standardized fuels. New biofuels can displace petroleum-based fuels and produce positive impacts on the environment, the economy, and the use of local energy sources. This review discusses the combustion, performance and other requirements of biofuels that will impact their near-term and long-term ability to replace petroleum fuels in transportation applications. Copyright © 2013 Elsevier Ltd. All rights reserved.
Extremely Durable, Flexible Supercapacitors with Greatly Improved Performance at High Temperatures.
Kim, Sung-Kon; Kim, Hae Jin; Lee, Jong-Chan; Braun, Paul V; Park, Ho Seok
2015-08-25
The reliability and durability of energy storage devices are as important as their essential characteristics (e.g., energy and power density) for stable power output and long lifespan and thus much more crucial under harsh conditions. However, energy storage under extreme conditions is still a big challenge because of unavoidable performance decays and the inevitable damage of components. Here, we report high-temperature operating, flexible supercapacitors (f-SCs) that can provide reliable power output and extreme durability under severe electrochemical, mechanical, and thermal conditions. The outstanding capacitive features (e.g., ∼40% enhancement of the rate capability and a maximum capacitances of 170 F g(-1) and 18.7 mF cm(-2) at 160 °C) are attributed to facilitated ion transport at elevated temperatures. Under high-temperature operation and/or a flexibility test in both static and dynamic modes at elevated temperatures >100 °C, the f-SCs showed extreme long-term stability of 100000 cycles (>93% of initial capacitance value) and mechanical durability after hundreds of bending cycles (at bend angles of 60-180°). Even at 120 °C, the versatile design of tandem serial and parallel f-SCs was demonstrated to provide both desirable energy and power requirements at high temperatures.
Hu, Yi; Ericsson, K Anders
2012-06-01
In a recent paper, Hu, Ericsson, Yang, and Lu (2009) found that an ability to memorize very long lists of digits is not mediated by the same mechanisms as exceptional memory for rapidly presented lists, which has been the traditional focus of laboratory research. Chao Lu is the holder of the Guinness World Record for reciting the most decimal positions of pi, yet he lacks an exceptional memory span for digits. In the first part of this paper we analyzed the reliability and structure of his reported encodings for lists of 300 digits and his application of the story mnemonic. Next, his study and recall times for lists of digits were analyzed to test hypotheses about his detailed encoding processes, and cued-recall performance was used to assess the structure of his encodings. Three experiments were then designed to interfere with the uniqueness of Chao Lu's story encodings, and evidence was found for his remarkable ability to adapt his encoding processes to reduce the interference. Finally, we show how his skills for encoding and recalling long lists can be accounted for within the theoretical framework of Ericsson and Kintsch's (1995) Long-Term Working Memory. Copyright © 2012 Elsevier Inc. All rights reserved.
A new generation of high-performance operational quantum sensors (Conference Presentation)
NASA Astrophysics Data System (ADS)
Lautier-Gaud, Jean; Desruelle, Bruno; Ménoret, Vincent; Schaff, Jean-François; Stern, Guillaume; Vermeulen, Pierre
2016-04-01
After 30 years of academic research in cold atom sciences, intensive developments are being conducted to improve the compactness and the reliability of experimental set-ups in order to transfer such devices from laboratory-based research to an operational utilization outside of the laboratory. We will present the long-lasting developments that we have been carrying to provide the first industrial cold-atom absolute gravimeter and the first industrial cold-atom atomic clock. We will present in detail the principles of operation and the main features of our instruments. Their performances in terms of sensitivity, stability and accuracy and the latest results they achieved will be reviewed. We will then discuss their use to support other research activities. One of the key technology elements of such instruments that need to be addressed is the laser system used to cool down and manipulate the atoms. A specific focus on our latest developments in this area in terms of performances will be proposed.
Development of a Mars Environmental Control and Life Support System (ECLSS).
NASA Technical Reports Server (NTRS)
Henninger, Donald L.
2016-01-01
ECLS systems for very long-duration human missions to Mars will be designed to operate reliably for many years and will never be returned to Earth. The need for high reliability is driven by unsympathetic abort scenarios. Abort from a Mars mission could be as long as 450 days to return to Earth. Simply put, the goal of an ECLSS is to duplicate the functions the Earth provides in terms of human living and working on our home planet but without the benefit of the Earth's large buffers - the atmospheres, the oceans and land masses. With small buffers a space-based ECLSS must operate as a true dynamic system rather than independent processors taking things from tanks, processing them, and then returning them to product tanks. Key is a development process that allows for a logical sequence of validating successful development (maturation) in a stepwise manner with key performance parameters (KPPs) at each step; especially KPPs for technologies evaluated in a full systems context with human crews on Earth and on space platforms such as the ISS. This paper will explore the implications of such an approach to ECLSS development and the roles of ground and space-based testing necessary to develop a highly reliable life support system for long duration human exploration missions. Historical development and testing of ECLS systems from Mercury to the International Space Station (ISS) will be reviewed. Current work as well as recommendations for future work will be described.
Gas adsorption/absorption heat switch, phase 1
NASA Technical Reports Server (NTRS)
Chan, C. K.
1987-01-01
The service life and/or reliability of far-infrared sensors on surveillance satellites is presently limited by the cryocooler. The life and/or reliability, however, can be extended by using redundant cryocoolers. To reduce parasitic heat leak, each stage of the inactive redundant cryocooler must be thermally isolated from the optical system, while each stage of the active cryocooler must be thermally connected to the system. The thermal break or the thermal contact can be controlled by heat switches. Among different physical mechanisms for heat switching, mechanically activated heat switches tend to have low reliability and, furthermore, require a large contact force. Magnetoresistive heat switches are, except at very low temperatures, of very low efficiency. Heat switches operated by the heat pipe principle usually require a long response time. A sealed gas gap heat switch operated by an adsorption pump has no mechanical motion and should provide the reliability and long lifetime required in long-term space missions. Another potential application of a heat switch is the thermal isolation of the optical plane during decontamination.
NASA Technical Reports Server (NTRS)
Smith, R. M.
1991-01-01
Numerous applications in the area of computer system analysis can be effectively studied with Markov reward models. These models describe the behavior of the system with a continuous-time Markov chain, where a reward rate is associated with each state. In a reliability/availability model, upstates may have reward rate 1 and down states may have reward rate zero associated with them. In a queueing model, the number of jobs of certain type in a given state may be the reward rate attached to that state. In a combined model of performance and reliability, the reward rate of a state may be the computational capacity, or a related performance measure. Expected steady-state reward rate and expected instantaneous reward rate are clearly useful measures of the Markov reward model. More generally, the distribution of accumulated reward or time-averaged reward over a finite time interval may be determined from the solution of the Markov reward model. This information is of great practical significance in situations where the workload can be well characterized (deterministically, or by continuous functions e.g., distributions). The design process in the development of a computer system is an expensive and long term endeavor. For aerospace applications the reliability of the computer system is essential, as is the ability to complete critical workloads in a well defined real time interval. Consequently, effective modeling of such systems must take into account both performance and reliability. This fact motivates our use of Markov reward models to aid in the development and evaluation of fault tolerant computer systems.
NASA Astrophysics Data System (ADS)
Qiang, Tian; Wang, Cong; Kim, Nam-Young
2017-08-01
A diplexer offering the advantages of compact size, high performance, and high reliability is proposed on the basis of advanced integrated passive device (IPD) fabrication techniques. The proposed diplexer is developed by combining a third-order low-pass filter (LPF) and a third-order high-pass filter (HPF), which are designed on the basis of the elliptic function prototype low-pass filter. Primary components, such as inductors and capacitors, are designed and fabricated with high Q-factor and appropriate values, and they are subsequently used to construct a compact diplexer having a chip area of 900 μm × 1100 μm (0.009 λ0 × 0.011 λ0, where λ0 is the guided wavelength). In addition, a small-outline transistor (SOT-6) packaging method is adopted, and reliability tests (including temperature, humidity, vibration, and pressure) are conducted to guarantee long-term stability and commercial success. The packaged measurement results indicate excellent RF performance with insertion losses of 1.39 dB and 0.75 dB at operation bands of 0.9 GHz and 1.8 GHz, respectively. The return loss is lower than 10 dB from 0.5 GHz to 4.0 GHz, while the isolation is higher than 15 dB from 0.5 GHz to 3.0 GHz. Thus, it can be concluded that the proposed SOT-6 packaged diplexer is a promising candidate for GSM/CDMA applications. Synthetic solution of diplexer design, RF performance optimization, fabrication process, packaging, RF response measurement, and reliability test is particularly explained and analyzed in this work.
Long-Term Bridge Performance (LTBP) Program Protocols, Version 1
DOT National Transportation Integrated Search
2016-01-01
The Long-Term Bridge Performance (LTBP) Program is a long-term research effort to collect scientific performance data from a representative sample of bridges in the United States. Data will be collected for in-service bridges using a variety of techn...
NASA Astrophysics Data System (ADS)
Shiga, Toshikazu; Chihara, Eiichi; Tanabe, Kazuhisa; Tanaka, Yoshifumi; Yamamoto, Katsuyuki
1998-01-01
A portable CW tissue oximeter of a 10-Hz sampling rate was developed for examination of pulsatile components of the output signals as a mean of checking the signal reliability during long-term monitoring. Feasible studies were performed on a healthy subject. Changes in Hb and HbO2 signals of cerebral tissue were continuously measured by placing a photoprobe on the forehead during 6-hour sleep. Pulsatile changes in Hb and HbO2 were steadily observed over a whole period of the recording. The phase relation of pulsation in Hb and HbO2 was almost inverse. Not only information for reliable monitoring but also physiological parameters with respect to cerebral circulation and metabolism could be obtained by measuring the pulsatile components.
NASA Astrophysics Data System (ADS)
Shiga, Toshikazu; Chihara, Eiichi; Tanabe, Kazuhisa; Tanaka, Yoshifumi; Yamamoto, Katsuyuki
1997-12-01
A portable CW tissue oximeter of a 10-Hz sampling rate was developed for examination of pulsatile components of the output signals as a mean of checking the signal reliability during long-term monitoring. Feasible studies were performed on a healthy subject. Changes in Hb and HbO2 signals of cerebral tissue were continuously measured by placing a photoprobe on the forehead during 6-hour sleep. Pulsatile changes in Hb and HbO2 were steadily observed over a whole period of the recording. The phase relation of pulsation in Hb and HbO2 was almost inverse. Not only information for reliable monitoring but also physiological parameters with respect to cerebral circulation and metabolism could be obtained by measuring the pulsatile components.
Smart ECG Monitoring Patch with Built-in R-Peak Detection for Long-Term HRV Analysis.
Lee, W K; Yoon, H; Park, K S
2016-07-01
Since heart rate variability (HRV) analysis is widely used to evaluate the physiological status of the human body, devices specifically designed for such applications are needed. To this end, we developed a smart electrocardiography (ECG) patch. The smart patch measures ECG using three electrodes integrated into the patch, filters the measured signals to minimize noise, performs analog-to-digital conversion, and detects R-peaks. The measured raw ECG data and the interval between the detected R-peaks can be recorded to enable long-term HRV analysis. Experiments were performed to evaluate the performance of the built-in R-wave detection, robustness of the device under motion, and applicability to the evaluation of mental stress. The R-peak detection results obtained with the device exhibited a sensitivity of 99.29%, a positive predictive value of 100.00%, and an error of 0.71%. The device also exhibited less motional noise than conventional ECG recording, being stable up to a walking speed of 5 km/h. When applied to mental stress analysis, the device evaluated the variation in HRV parameters in the same way as a normal ECG, with very little difference. This device can help users better understand their state of health and provide physicians with more reliable data for objective diagnosis.
NASA Technical Reports Server (NTRS)
White, Mark; Huang, Bing; Qin, Jin; Gur, Zvi; Talmor, Michael; Chen, Yuan; Heidecker, Jason; Nguyen, Duc; Bernstein, Joseph
2005-01-01
As microelectronics are scaled in to the deep sub-micron regime, users of advanced technology CMOS, particularly in high-reliability applications, should reassess how scaling effects impact long-term reliability. An experimental based reliability study of industrial grade SRAMs, consisting of three different technology nodes, is proposed to substantiate current acceleration models for temperature and voltage life-stress relationships. This reliability study utilizes step-stress techniques to evaluate memory technologies (0.25mum, 0.15mum, and 0.13mum) embedded in many of today's high-reliability space/aerospace applications. Two acceleration modeling approaches are presented to relate experimental FIT calculations to Mfr's qualification data.
Complementary Reliability-Based Decodings of Binary Linear Block Codes
NASA Technical Reports Server (NTRS)
Fossorier, Marc P. C.; Lin, Shu
1997-01-01
This correspondence presents a hybrid reliability-based decoding algorithm which combines the reprocessing method based on the most reliable basis and a generalized Chase-type algebraic decoder based on the least reliable positions. It is shown that reprocessing with a simple additional algebraic decoding effort achieves significant coding gain. For long codes, the order of reprocessing required to achieve asymptotic optimum error performance is reduced by approximately 1/3. This significantly reduces the computational complexity, especially for long codes. Also, a more efficient criterion for stopping the decoding process is derived based on the knowledge of the algebraic decoding solution.
Revising the Lubben Social Network Scale for use in residential long-term care settings.
Munn, Jean; Radey, Melissa; Brown, Kristin; Kim, Hyejin
2018-04-19
We revised the Lubben Social Network Scale (LSNS) to develop a measure of social support specific to residential long-term care (LTC) settings, the LSNS-LTC with five domains (i.e., family, friends, residents, volunteers, and staff). The authors modified the LSNS-18 to capture sources of social support specific to LTC, specifically relationships with residents, volunteers, and staff. We piloted the resultant 28-item measure with 64 LTC residents. Fifty-four respondents provided adequate information for analyses that included descriptive statistics and reliability coefficients. Twenty of the items performed well (had correlations >0.3, overall α = 0.85) and were retained. Three items required modification. The five items related to volunteers were eliminated due to extensive (>15%) missing data resulting in a proposed 23-item measure. We identified, and to some degree quantified, supportive relationships within the LTC environment, while developing a self-report tool to measure social support in these settings.
Bohata, J; Zvanovec, S; Pesek, P; Korinek, T; Mansour Abadi, M; Ghassemlooy, Z
2016-03-10
This paper describes the experimental verification of the utilization of long-term evolution radio over fiber (RoF) and radio over free space optics (RoFSO) systems using dual-polarization signals for cloud radio access network applications determining the specific utilization limits. A number of free space optics configurations are proposed and investigated under different atmospheric turbulence regimes in order to recommend the best setup configuration. We show that the performance of the proposed link, based on the combination of RoF and RoFSO for 64 QAM at 2.6 GHz, is more affected by the turbulence based on the measured difference error vector magnitude value of 5.5%. It is further demonstrated the proposed systems can offer higher noise immunity under particular scenarios with the signal-to-noise ratio reliability limit of 5 dB in the radio frequency domain for RoF and 19.3 dB in the optical domain for a combination of RoF and RoFSO links.
NASA Astrophysics Data System (ADS)
Deshayes, Yannick; Verdier, Frederic; Bechou, Laurent; Tregon, Bernard; Danto, Yves; Laffitte, Dominique; Goudard, Jean Luc
2004-09-01
High performance and high reliability are two of the most important goals driving the penetration of optical transmission into telecommunication systems ranging from 880 nm to 1550 nm. Lifetime prediction defined as the time at which a parameter reaches its maximum acceptable shirt still stays the main result in terms of reliability estimation for a technology. For optoelectronic emissive components, selection tests and life testing are specifically used for reliability evaluation according to Telcordia GR-468 CORE requirements. This approach is based on extrapolation of degradation laws, based on physics of failure and electrical or optical parameters, allowing both strong test time reduction and long-term reliability prediction. Unfortunately, in the case of mature technology, there is a growing complexity to calculate average lifetime and failure rates (FITs) using ageing tests in particular due to extremely low failure rates. For present laser diode technologies, time to failure tend to be 106 hours aged under typical conditions (Popt=10 mW and T=80°C). These ageing tests must be performed on more than 100 components aged during 10000 hours mixing different temperatures and drive current conditions conducting to acceleration factors above 300-400. These conditions are high-cost, time consuming and cannot give a complete distribution of times to failure. A new approach consists in use statistic computations to extrapolate lifetime distribution and failure rates in operating conditions from physical parameters of experimental degradation laws. In this paper, Distributed Feedback single mode laser diodes (DFB-LD) used for 1550 nm telecommunication network working at 2.5 Gbit/s transfer rate are studied. Electrical and optical parameters have been measured before and after ageing tests, performed at constant current, according to Telcordia GR-468 requirements. Cumulative failure rates and lifetime distributions are computed using statistic calculations and equations of drift mechanisms versus time fitted from experimental measurements.
7 CFR 1710.254 - Alternative sources of power.
Code of Federal Regulations, 2012 CFR
2012-01-01
... facilities constitute an effective and economical means of meeting the power requirements of the consumers. A... proposals on an economic, present-value basis, giving consideration to cost-effectiveness, reliability of service, the short-term and long-term financial viability of the supplier, and the financial risk to the...
7 CFR 1710.254 - Alternative sources of power.
Code of Federal Regulations, 2010 CFR
2010-01-01
... facilities constitute an effective and economical means of meeting the power requirements of the consumers. A... proposals on an economic, present-value basis, giving consideration to cost-effectiveness, reliability of service, the short-term and long-term financial viability of the supplier, and the financial risk to the...
7 CFR 1710.254 - Alternative sources of power.
Code of Federal Regulations, 2011 CFR
2011-01-01
... facilities constitute an effective and economical means of meeting the power requirements of the consumers. A... proposals on an economic, present-value basis, giving consideration to cost-effectiveness, reliability of service, the short-term and long-term financial viability of the supplier, and the financial risk to the...
7 CFR 1710.254 - Alternative sources of power.
Code of Federal Regulations, 2014 CFR
2014-01-01
... facilities constitute an effective and economical means of meeting the power requirements of the consumers. A... proposals on an economic, present-value basis, giving consideration to cost-effectiveness, reliability of service, the short-term and long-term financial viability of the supplier, and the financial risk to the...
7 CFR 1710.254 - Alternative sources of power.
Code of Federal Regulations, 2013 CFR
2013-01-01
... facilities constitute an effective and economical means of meeting the power requirements of the consumers. A... proposals on an economic, present-value basis, giving consideration to cost-effectiveness, reliability of service, the short-term and long-term financial viability of the supplier, and the financial risk to the...
Long-term Behavioral Tracking of Freely Swimming Weakly Electric Fish
Jun, James J.; Longtin, André; Maler, Leonard
2014-01-01
Long-term behavioral tracking can capture and quantify natural animal behaviors, including those occurring infrequently. Behaviors such as exploration and social interactions can be best studied by observing unrestrained, freely behaving animals. Weakly electric fish (WEF) display readily observable exploratory and social behaviors by emitting electric organ discharge (EOD). Here, we describe three effective techniques to synchronously measure the EOD, body position, and posture of a free-swimming WEF for an extended period of time. First, we describe the construction of an experimental tank inside of an isolation chamber designed to block external sources of sensory stimuli such as light, sound, and vibration. The aquarium was partitioned to accommodate four test specimens, and automated gates remotely control the animals' access to the central arena. Second, we describe a precise and reliable real-time EOD timing measurement method from freely swimming WEF. Signal distortions caused by the animal's body movements are corrected by spatial averaging and temporal processing stages. Third, we describe an underwater near-infrared imaging setup to observe unperturbed nocturnal animal behaviors. Infrared light pulses were used to synchronize the timing between the video and the physiological signal over a long recording duration. Our automated tracking software measures the animal's body position and posture reliably in an aquatic scene. In combination, these techniques enable long term observation of spontaneous behavior of freely swimming weakly electric fish in a reliable and precise manner. We believe our method can be similarly applied to the study of other aquatic animals by relating their physiological signals with exploratory or social behaviors. PMID:24637642
Poster - Thur Eve - 10: Long term stability of VMAT quality assurance parameters using an EPID.
Pekar, J; Diamond, K R
2012-07-01
The rapidly growing use of volumetric modulated arc therapy (VMAT) treatments in radiation therapy calls for a quantitative, automated, and reliable quality assurance (QA) procedure that can be used routinely in the clinical setting. In this work, we present a series VMAT QA procedures used to assess dynamic multi-leaf collimator (MLC) positional accuracy, variable dose-rate accuracy, and MLC leaf speed accuracy. The QA procedures were performed using amorphous silicon electronic portal imaging devices (EPID) to determine the long term stability of the measured parameters on two Varian linear accelerators. The measurements were repeated weekly on both linear accelerators for a period of three months and the EPID images were analyzed using custom Matlab software. The results of the picket fence tests indicate that MLC leaf positions can be identified to within 0.11 mm and 0.15 mm for static gantry delivery and VMAT delivery respectively. In addition, the dose-rate, gantry speed and MLC leaf speed tests both show very good stability over the measurement period. The measurements thus far, suggest that a number of the dosimetry tests may be suitable for quarterly QA for Varian iX and Trilogy linacs. However, additional measurements are required to confirm the frequency with which each test is required for safe and reliable VMAT delivery at our centre. © 2012 American Association of Physicists in Medicine.
Diaz, Claris; Farr, Tracy D; Harrison, David J; Fuller, Anna; Tokarczuk, Paweł F; Stewart, Andrew J; Paisey, Stephen J; Dunnett, Stephen B
2016-01-01
In order to test therapeutics, functional assessments are required. In pre-clinical stroke research, there is little consensus regarding the most appropriate behavioural tasks to assess deficits, especially when testing over extended times in milder models with short occlusion times and small lesion volumes. In this study, we comprehensively assessed 16 different behavioural tests, with the aim of identifying those that show robust, reliable and stable deficits for up to two months. These tasks are regularly used in stroke research, as well as being useful for examining striatal dysfunction in models of Huntington’s and Parkinson’s disease. Two cohorts of male Wistar rats underwent the intraluminal filament model of middle cerebral artery occlusion (30 min) and were imaged 24 h later. This resulted in primarily subcortical infarcts, with a small amount of cortical damage. Animals were tested, along with sham and naïve groups at 24 h, seven days, and one and two months. Following behavioural testing, brains were processed and striatal neuronal counts were performed alongside measurements of total brain and white matter atrophy. The staircase, adjusting steps, rotarod and apomorphine-induced rotations were the most reliable for assessing long-term deficits in the 30 min transient middle cerebral artery occlusion model of stroke. PMID:27317655
NASA Astrophysics Data System (ADS)
Sin, Yongkun; Lingley, Zachary; Brodie, Miles; Presser, Nathan; Moss, Steven C.
2017-02-01
High-power single-mode (SM) and multi-mode (MM) InGaAs-AlGaAs strained quantum well (QW) lasers are critical components for both telecommunications and space satellite communications systems. However, little has been reported on failure modes and degradation mechanisms of high-power SM and MM InGaAs-AlGaAs strained QW lasers although it is crucial to understand failure modes and underlying degradation mechanisms in developing these lasers that meet lifetime requirements for space satellite systems, where extremely high reliability of these lasers is required. Our present study addresses the aforementioned issues by performing long-term life-tests followed by failure mode analysis (FMA) and physics of failure investigation. We performed long-term accelerated life-tests on state-of-the-art SM and MM InGaAs-AlGaAs strained QW lasers under ACC (automatic current control) mode. Our life-tests have accumulated over 25,000 test hours for SM lasers and over 35,000 test hours for MM lasers. FMA was performed on failed SM lasers using electron beam induced current (EBIC). This technique allowed us to identify failure types by observing dark line defects. All the SM failures we studied showed catastrophic and sudden degradation and all of these failures were bulk failures. Our group previously reported that bulk failure or COBD (catastrophic optical bulk damage) is the dominant failure mode of MM InGaAs-AlGaAs strained QW lasers. Since degradation mechanisms responsible for COBD are still not well understood, we also employed other techniques including focused ion beam (FIB) processing and high-resolution TEM to further study dark line defects and dislocations in post-aged lasers. Our long-term life-test results and FMA results are reported.
Bearing Procurement Analysis Method by Total Cost of Ownership Analysis and Reliability Prediction
NASA Astrophysics Data System (ADS)
Trusaji, Wildan; Akbar, Muhammad; Sukoyo; Irianto, Dradjad
2018-03-01
In making bearing procurement analysis, price and its reliability must be considered as decision criteria, since price determines the direct cost as acquisition cost and reliability of bearing determine the indirect cost such as maintenance cost. Despite the indirect cost is hard to identify and measured, it has high contribution to overall cost that will be incurred. So, the indirect cost of reliability must be considered when making bearing procurement analysis. This paper tries to explain bearing evaluation method with the total cost of ownership analysis to consider price and maintenance cost as decision criteria. Furthermore, since there is a lack of failure data when bearing evaluation phase is conducted, reliability prediction method is used to predict bearing reliability from its dynamic load rating parameter. With this method, bearing with a higher price but has higher reliability is preferable for long-term planning. But for short-term planning the cheaper one but has lower reliability is preferable. This contextuality can give rise to conflict between stakeholders. Thus, the planning horizon needs to be agreed by all stakeholder before making a procurement decision.
Multi-objective optimization of GENIE Earth system models.
Price, Andrew R; Myerscough, Richard J; Voutchkov, Ivan I; Marsh, Robert; Cox, Simon J
2009-07-13
The tuning of parameters in climate models is essential to provide reliable long-term forecasts of Earth system behaviour. We apply a multi-objective optimization algorithm to the problem of parameter estimation in climate models. This optimization process involves the iterative evaluation of response surface models (RSMs), followed by the execution of multiple Earth system simulations. These computations require an infrastructure that provides high-performance computing for building and searching the RSMs and high-throughput computing for the concurrent evaluation of a large number of models. Grid computing technology is therefore essential to make this algorithm practical for members of the GENIE project.
The 2001 Mars In-Situ-Propellant-Production Precursor (MIP) Flight Demonstration
NASA Technical Reports Server (NTRS)
Kaplan, David I.; Baird, R. Scott; Ratliff, James E.; Baraona, Cosmo R.; Jenkins, Phillip P.; Landis, Geoffrey A.; Scheiman, David A.; Brinza, David E.; Johnson, Kenneth R.; Karlmann, Paul B.;
2000-01-01
The successful performance of the five individual demonstrations of MARS IN-SITU-PROPELLANT-PRODUCTION PRECURSOR (MIP) will provide both knowledge of and confidence in the reliability of this technology. At the completion of this flight demonstration, the MIP Team will be able to: a) recommend preferred hardware configurations for the intake and adsorption of carbon dioxide from the Martian atmosphere; b) understand the performance characteristics of zirconia cells to generate propellant-grade oxygen; c) understand long-term performance characteristics of advanced solar cells/arrays operated in the actual Mars environment; d) evaluate the functionality of methods to mitigate the deposition of airborne dust onto solar arrays; and e) recommend preferred hardware designs for innovative thermal management including the radiation of heat to the outside environment.
Vanwonterghem, Inka; Jensen, Paul D; Dennis, Paul G; Hugenholtz, Philip; Rabaey, Korneel; Tyson, Gene W
2014-01-01
A replicate long-term experiment was conducted using anaerobic digestion (AD) as a model process to determine the relative role of niche and neutral theory on microbial community assembly, and to link community dynamics to system performance. AD is performed by a complex network of microorganisms and process stability relies entirely on the synergistic interactions between populations belonging to different functional guilds. In this study, three independent replicate anaerobic digesters were seeded with the same diverse inoculum, supplied with a model substrate, α-cellulose, and operated for 362 days at a 10-day hydraulic residence time under mesophilic conditions. Selective pressure imposed by the operational conditions and model substrate caused large reproducible changes in community composition including an overall decrease in richness in the first month of operation, followed by synchronised population dynamics that correlated with changes in reactor performance. This included the synchronised emergence and decline of distinct Ruminococcus phylotypes at day 148, and emergence of a Clostridium and Methanosaeta phylotype at day 178, when performance became stable in all reactors. These data suggest that many dynamic functional niches are predictably filled by phylogenetically coherent populations over long time scales. Neutral theory would predict that a complex community with a high degree of recognised functional redundancy would lead to stochastic changes in populations and community divergence over time. We conclude that deterministic processes may play a larger role in microbial community dynamics than currently appreciated, and under controlled conditions it may be possible to reliably predict community structural and functional changes over time. PMID:24739627
Bridge reliability assessment based on the PDF of long-term monitored extreme strains
NASA Astrophysics Data System (ADS)
Jiao, Meiju; Sun, Limin
2011-04-01
Structural health monitoring (SHM) systems can provide valuable information for the evaluation of bridge performance. As the development and implementation of SHM technology in recent years, the data mining and use has received increasingly attention and interests in civil engineering. Based on the principle of probabilistic and statistics, a reliability approach provides a rational basis for analysis of the randomness in loads and their effects on structures. A novel approach combined SHM systems with reliability method to evaluate the reliability of a cable-stayed bridge instrumented with SHM systems was presented in this paper. In this study, the reliability of the steel girder of the cable-stayed bridge was denoted by failure probability directly instead of reliability index as commonly used. Under the assumption that the probability distributions of the resistance are independent to the responses of structures, a formulation of failure probability was deduced. Then, as a main factor in the formulation, the probability density function (PDF) of the strain at sensor locations based on the monitoring data was evaluated and verified. That Donghai Bridge was taken as an example for the application of the proposed approach followed. In the case study, 4 years' monitoring data since the operation of the SHM systems was processed, and the reliability assessment results were discussed. Finally, the sensitivity and accuracy of the novel approach compared with FORM was discussed.
Operation and planning of coordinated natural gas and electricity infrastructures
NASA Astrophysics Data System (ADS)
Zhang, Xiaping
Natural gas is becoming rapidly the optimal choice for fueling new generating units in electric power system driven by abundant natural gas supplies and environmental regulations that are expected to cause coal-fired generation retirements. The growing reliance on natural gas as a dominant fuel for electricity generation throughout North America has brought the interaction between the natural gas and power grids into sharp focus. The primary concern and motivation of this research is to address the emerging interdependency issues faced by the electric power and natural gas industry. This thesis provides a comprehensive analysis of the interactions between the two systems regarding the short-term operation and long-term infrastructure planning. Natural gas and renewable energy appear complementary in many respects regarding fuel price and availability, environmental impact, resource distribution and dispatchability. In addition, demand response has also held the promise of making a significant contribution to enhance system operations by providing incentives to customers for a more flat load profile. We investigated the coordination between natural gas-fired generation and prevailing nontraditional resources including renewable energy, demand response so as to provide economical options for optimizing the short-term scheduling with the intense natural gas delivery constraints. As the amount and dispatch of gas-fired generation increases, the long-term interdependency issue is whether there is adequate pipeline capacity to provide sufficient gas to natural gas-fired generation during the entire planning horizon while it is widely used outside the power sector. This thesis developed a co-optimization planning model by incorporating the natural gas transportation system into the multi-year resource and transmission system planning problem. This consideration would provide a more comprehensive decision for the investment and accurate assessment for system adequacy and reliability. With the growing reliance on natural gas and widespread utilization of highly efficient combined heat and power (CHP), it is also questionable that whether the independent design of infrastructures can meet potential challenges of future energy supply. To address this issue, this thesis proposed an optimization framework for a sustainable multiple energy system expansion planning based on an energy hub model while considering the energy efficiency, emission and reliability performance. In addition, we introduced the probabilistic reliability evaluation and flow network analysis into the multiple energy system design in order to obtain an optimal and reliable network topology.
NASA Astrophysics Data System (ADS)
Erdal, Daniel; Cirpka, Olaf A.
2017-04-01
Regional groundwater flow strongly depends on groundwater recharge and hydraulic conductivity. While conductivity is a spatially variable field, recharge can vary in both space and time. None of the two fields can be reliably observed on larger scales, and their estimation from other sparse data sets is an open topic. Further, common hydraulic-head observations may not suffice to constrain both fields simultaneously. In the current work we use the Ensemble Kalman filter to estimate spatially variable conductivity, spatiotemporally variable recharge and porosity for a synthetic phreatic aquifer. We use transient hydraulic-head and one spatially distributed set of environmental tracer observations to constrain the estimation. As environmental tracers generally reside for a long time in an aquifer, they require long simulation times and carries a long memory that makes them highly unsuitable for use in a sequential framework. Therefore, in this work we use the environmental tracer information to precondition the initial ensemble of recharge and conductivities, before starting the sequential filter. Thereby, we aim at improving the performance of the sequential filter by limiting the range of the recharge to values similar to the long-term annual recharge means and by creating an initial ensemble of conductivities that show similar pattern and values to the true field. The sequential filter is then used to further improve the parameters and to estimate the short term temporal behavior as well as the temporally evolving head field needed for short term predictions within the aquifer. For a virtual reality covering a subsection of the river Neckar it is shown that the use of environmental tracers can improve the performance of the filter. Results using the EnKF with and without this preconditioned initial ensemble are evaluated and discussed.
Field Performance of ISFET based Deep Ocean pH Sensors
NASA Astrophysics Data System (ADS)
Branham, C. W.; Murphy, D. J.
2017-12-01
Historically, ocean pH time series data was acquired from infrequent shipboard grab samples and measured using labor intensive spectrophotometry methods. However, with the introduction of robust and stable ISFET pH sensors for use in ocean applications a paradigm shift in the methods used to acquire long-term pH time series data has occurred. Sea-Bird Scientific played a critical role in the adoption this new technology by commercializing the SeaFET pH sensor and float pH Sensor developed by the MBARI chemical sensor group. Sea-Bird Scientific continues to advance this technology through a concerted effort to improve pH sensor accuracy and reliability by characterizing their performance in the laboratory and field. This presentation will focus on calibration of the ISFET pH sensor, evaluate its analytical performance, and validate performance using recent field data.
Just a minute meditation: Rapid voluntary conscious state shifts in long term meditators.
Nair, Ajay Kumar; Sasidharan, Arun; John, John P; Mehrotra, Seema; Kutty, Bindu M
2017-08-01
Meditation induces a modified state of consciousness that remains under voluntary control. Can meditators rapidly and reversibly bring about mental state changes on demand? To check, we carried out 128 channel EEG recordings on Brahma Kumaris Rajayoga meditators (36 long term: median 14240h meditation; 25 short term: 1095h) and controls (25) while they tried to switch every minute between rest and meditation states in different conditions (eyes open and closed; before and after an engaging task). Long term meditators robustly shifted states with enhanced theta power (4-8Hz) during meditation. Short term meditators had limited ability to shift between states and showed increased lower alpha power (8-10Hz) during eyes closed meditation only when pre and post task data were combined. Controls could not shift states. Thus trained beginners can reliably meditate but it takes long term practice to exercise more refined control over meditative states. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klise, Geoffrey T.; Hill, Roger; Walker, Andy
The use of the term 'availability' to describe a photovoltaic (PV) system and power plant has been fraught with confusion for many years. A term that is meant to describe equipment operational status is often omitted, misapplied or inaccurately combined with PV performance metrics due to attempts to measure performance and reliability through the lens of traditional power plant language. This paper discusses three areas where current research in standards, contract language and performance modeling is improving the way availability is used with regards to photovoltaic systems and power plants.
Long-Term Memory Performance in Adult ADHD.
Skodzik, Timo; Holling, Heinz; Pedersen, Anya
2017-02-01
Memory problems are a frequently reported symptom in adult ADHD, and it is well-documented that adults with ADHD perform poorly on long-term memory tests. However, the cause of this effect is still controversial. The present meta-analysis examined underlying mechanisms that may lead to long-term memory impairments in adult ADHD. We performed separate meta-analyses of measures of memory acquisition and long-term memory using both verbal and visual memory tests. In addition, the influence of potential moderator variables was examined. Adults with ADHD performed significantly worse than controls on verbal but not on visual long-term memory and memory acquisition subtests. The long-term memory deficit was strongly statistically related to the memory acquisition deficit. In contrast, no retrieval problems were observable. Our results suggest that memory deficits in adult ADHD reflect a learning deficit induced at the stage of encoding. Implications for clinical and research settings are presented.
Harvey, Philip D.; Reichenberg, Abraham; Bowie, Christopher R.; Patterson, Thomas L.; Heaton, Robert K.
2010-01-01
Background Chronically institutionalized patients with schizophrenia have been reported to manifest cognitive and functional decline. Previous studies were limited by the fact that current environment could not be separated from life-time illness course. The present study examined older outpatients who varied in their lifetime history of long-term psychiatric inpatient stay. Methods Community dwelling patients with schizophrenia (n=111) and healthy comparison subjects (n=76) were followed up to 45 months and examined two or more times with a neuropsychological (NP) battery and performance-based measures of everyday living skills (UCSD Performance-based skills assessment; UPSA) and social competence. A mixed-effects model repeated-measures method was used to examine changes. Results There was a significant effect of institutional stay on the course of the UPSA. When the schizophrenia patients who completed all three assessments were divided on the basis of length of institutional stay and compared to healthy comparison subjects, patients with longer stays worsened on the UPSA and social competence while patients with shorter stays improved. For NP performance, both patient samples worsened slightly while the HC group manifested a practice effect. Reliable change index (RCI) analyses showed that worsening on the UPSA for longer stay patients was definitely nonrandom. Conclusions Life-time history of institutional stay was associated with worsening on measures of social and everyday living skills. NP performance in schizophrenia did not evidence the practice effect seen in the HC sample. These data suggest that schizophrenia patients with a history of long institutional stay may worsen even if they are no longer institutionalized. PMID:20202624
The self-care behavior inventory: a model for behavioral instrument development.
McLaughlin, J; Sliepcevich, E M
1985-09-01
The Self-Care Behavior (SCB) Inventory was developed as part of a long-term study of self-care practices of persons who have multiple sclerosis (MS) in Denmark. The universe of behaviors regarding the physical, social, emotional, environmental, and spiritual aspects of coping with the illness was ascertained by informal and formal interviews. Respondents were asked not only what behavior was performed, but also who performed it, how it was performed, why, when, and where it was performed, and where the knowledge to perform the behavior in this manner was acquired, such as a lay-referral network, physician, social worker, spouse, or media. The inventory went through a series of drafts and pre-tests, resulting in a final version that met criteria for validity and reliability. The model presented for the development of the SCB Inventory can be useful for designing behavioral inventories and assessment tools for other chronic conditions such as arthritis, epilepsy, and diabetes.
ERIC Educational Resources Information Center
Altmeyer, Michael; Schweizer, Karl; Reiss, Siegbert; Ren, Xuezhu; Schreiner, Michael
2013-01-01
Performance in working memory and short-term memory tasks was employed for predicting performance in a long-term memory task in order to find out about the underlying processes. The types of memory were represented by versions of the Posner Task, the Backward Counting Task and the Sternberg Task serving as measures of long-term memory, working…
40 K single-stage coaxial pulse tube cryocoolers
NASA Astrophysics Data System (ADS)
Dang, Haizheng
2012-04-01
Several 40 K single-stage coaxial high frequency pulse tube cryocoolers (PTCs) have been developed to provide reliable and low-noise cooling for GaAs/AlGaAs Quantum-Well infrared photodetectors (QWIPs). The inertance tubes together with the gas reservoir become the only phase shifter to guarantee the required long-term stability. The mixed regenerator consisting of three segments has been developed to enhance the overall regenerator performance. At present, the cooler prototype has achieved a no-load temperature of 29.7 K and can typically provide 860 mW cooling at 40 K with 200 W electric input power rejecting at 300 K. The performance characteristics such as the temperature stability and ambient temperature adaptability are also presented.
Evaluation of ZFS as an efficient WLCG storage backend
NASA Astrophysics Data System (ADS)
Ebert, M.; Washbrook, A.
2017-10-01
A ZFS based software raid system was tested for performance against a hardware raid system providing storage based on the traditional Linux file systems XFS and EXT4. These tests were done for a healthy raid array as well as for a degraded raid array and during the rebuild of a raid array. It was found that ZFS performs better in almost all test scenarios. In addition, distinct features of ZFS were tested for WLCG data storage use, like compression and higher raid levels with triple redundancy information. The long term reliability was observed after converting all production storage servers at the Edinburgh WLCG Tier-2 site to ZFS, resulting in about 1.2PB of ZFS based storage at this site.
Bruce, Jared; Echemendia, Ruben; Tangeman, Lindy; Meeuwisse, Willem; Comper, Paul; Hutchison, Michael; Aubry, Mark
2016-01-01
Computerized neuropsychological tests are frequently used to assist in return-to-play decisions following sports concussion. However, due to concerns about test reliability, the Centers for Disease Control and Prevention recommends yearly baseline testing. The standard practice that has developed in baseline/postinjury comparisons is to examine the difference between the most recent baseline test and postconcussion performance. Drawing from classical test theory, the present study investigated whether temporal stability could be improved by taking an alternate approach that uses the aggregate of 2 baselines to more accurately estimate baseline cognitive ability. One hundred fifteen English-speaking professional hockey players with 3 consecutive Immediate Postconcussion Assessment and Testing (ImPACT) baseline tests were extracted from a clinical program evaluation database overseen by the National Hockey League and National Hockey League Players' Association. The temporal stability of ImPACT composite scores was significantly increased by aggregating test performance during Sessions 1 and 2 to predict performance during Session 3. Using this approach, the 2-factor Memory (r = .72) and Speed (r = .79) composites of ImPACT showed acceptable long-term reliability. Using the aggregate of 2 baseline scores significantly improves temporal stability and allows for more accurate predictions of cognitive change following concussion. Clinicians are encouraged to estimate baseline abilities by taking into account all of an athlete's previous baseline scores.
Advanced Reactor PSA Methodologies for System Reliability Analysis and Source Term Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, D.; Brunett, A.; Passerini, S.
Beginning in 2015, a project was initiated to update and modernize the probabilistic safety assessment (PSA) of the GE-Hitachi PRISM sodium fast reactor. This project is a collaboration between GE-Hitachi and Argonne National Laboratory (Argonne), and funded in part by the U.S. Department of Energy. Specifically, the role of Argonne is to assess the reliability of passive safety systems, complete a mechanistic source term calculation, and provide component reliability estimates. The assessment of passive system reliability focused on the performance of the Reactor Vessel Auxiliary Cooling System (RVACS) and the inherent reactivity feedback mechanisms of the metal fuel core. Themore » mechanistic source term assessment attempted to provide a sequence specific source term evaluation to quantify offsite consequences. Lastly, the reliability assessment focused on components specific to the sodium fast reactor, including electromagnetic pumps, intermediate heat exchangers, the steam generator, and sodium valves and piping.« less
A Descriptive, Multiyear Examination of Positive Behavior Support
ERIC Educational Resources Information Center
Dunlap, Glen; Carr, Edward G.; Horner, Robert H.; Koegel, Robert L.; Sailor, Wayne; Clarke, Shelley; Koegel, Lynn Kern; Albin, Richard W.; Vaughn, Bobbie J.; McLaughlin, Darlene Magito; James, Kim Mullen; Todd, Anne W.; Newton, J. Stephen; Lucyshyn, Joseph; Griggs, Peter; Bohanon, Hank; Choi, Jeong Hoon; Vismara, Laurie; Minjarez, Mendy Boettcher; Buschbacher, Pamelazita; Fox, Lise
2010-01-01
A major goal of positive behavior support (PBS) is to produce broad-based, long-term improvements in adaptive behavior; however, the empirical base, at present, is mainly composed of relatively short-term studies carried out in circumscribed contexts. Therefore, a need exists for reliable data that can inform the field regarding the comprehensive…
Measuring and Promoting Acceptance of Young Children with Disabilities.
ERIC Educational Resources Information Center
Favazza, Paddy C.; Phillipsen, Leslie; Kumar, Poonam
2000-01-01
Results of two studies indicate the Acceptance Scale for Kindergartners was reliable with a sample of minority, low socioeconomic status children and that children exposed to all of the components of an intervention designed to promote acceptance of young children with disabilities had short-term and long-term gains in acceptance. (Contains…
Wind and turbine characteristics needed for integration of wind turbine arrays into a utility system
NASA Technical Reports Server (NTRS)
Park, G. L.
1982-01-01
Wind data and wind turbine generator (WTG) performance characteristics are often available in a form inconvenient for use by utility planners and engineers. The steps used by utility planners are summarized and the type of wind and WTG data needed for integration of WTG arrays suggested. These included long term yearly velocity averages for preliminary site feasibility, hourly velocities on a 'wind season' basis for more detailed economic analysis and for reliability studies, worst-case velocity profiles for gusts, and various minute-to-hourly velocity profiles for estimating the effect of longer-term wind fluctuations on utility operations. wind turbine data needed includes electrical properties of the generator, startup and shutdown characteristics, protection characteristics, pitch control response and control strategy, and electro-mechanical model for stability analysis.
Survey of critical failure events in on-chip interconnect by fault tree analysis
NASA Astrophysics Data System (ADS)
Yokogawa, Shinji; Kunii, Kyousuke
2018-07-01
In this paper, a framework based on reliability physics is proposed for adopting fault tree analysis (FTA) to the on-chip interconnect system of a semiconductor. By integrating expert knowledge and experience regarding the possibilities of failure on basic events, critical issues of on-chip interconnect reliability will be evaluated by FTA. In particular, FTA is used to identify the minimal cut sets with high risk priority. Critical events affecting the on-chip interconnect reliability are identified and discussed from the viewpoint of long-term reliability assessment. The moisture impact is evaluated as an external event.
Fino, Edita; Mazzetti, Michela
2018-04-23
Smartphone applications are considered as the prime candidate for the purposes of large-scale, low-cost and long-term sleep monitoring. How reliable and scientifically grounded is smartphone-based assessment of healthy and disturbed sleep remains a key issue in this direction. Here we offer a review of validation studies of sleep applications to the aim of providing some guidance in terms of their reliability to assess sleep in healthy and clinical populations, and stimulating further examination of their potential for clinical use and improved sleep hygiene. Electronic literature review was conducted on Pubmed. Eleven validation studies published since 2012 were identified, evaluating smartphone applications' performance compared to standard methods of sleep assessment in healthy and clinical samples. Studies with healthy populations show that most sleep applications meet or exceed accuracy levels of wrist-based actigraphy in sleep-wake cycle discrimination, whereas performance levels drop in individuals with low sleep efficiency (SE) and in clinical populations, mirroring actigraphy results. Poor correlation with polysomnography (PSG) sleep sub-stages is reported by most accelerometer-based apps. However, multiple parameter-based applications (i.e., EarlySense, SleepAp) showed good capability in detection of sleep-wake stages and sleep-related breathing disorders (SRBD) like obstructive sleep apnea (OSA) respectively with values similar to PSG. While the reviewed evidence suggests a potential role of smartphone sleep applications in pre-screening of SRBD, more experimental studies are warranted to assess their reliability in sleep-wake detection particularly. Apps' utility in post treatment follow-up at home or as an adjunct to the sleep diary in clinical setting is also stressed.
Long-term sera storage does not significantly modify the interpretation of toxoplasmosis serologies.
Dard, C; Bailly, S; Drouet, T; Fricker-Hidalgo, H; Brenier-Pinchart, M P; Pelloux, H
2017-03-01
Serological investigation of Toxoplasma gondii can answer many questions about toxoplasmosis in human pathology. Along these lines, studies on serum storage in biobanks need to be performed especially in terms of determining the impact of storage on relevance of sera analysis after freezing. This study assessed the impact of long-term sera storage on the stability of anti-Toxoplasma immunoglobulins. The stability of anti-Toxoplasma IgG and IgM was studied in 244 and 242 sera respectively, stored at -20°C from one month to ten years. ELISA-immunoassay (Vidas®, bioMérieux) was used for initial and post-storage analyses. Linear models for repeated measures and subgroup analyses were performed to assess the effect of storage duration and sample characteristics on immunoglobulins stability. Until ten years, the variability attributed to storage (maximum 8.07% for IgG, 13.17% for IgM) was below the variations inherent to the serological technique and allowed by quality assurance systems (15%). Subgroup analysis reported no variation attributed to sera storage. Serological interpretation was modified for 3 sera (1.2%) tested for IgM, all stored more than seven years. Anti-Toxoplasma immunoglobulins can reliably be measured for at least up to six years of storage with no modification of interpretation of toxoplasmosis serologies. Copyright © 2017 Elsevier B.V. All rights reserved.
Automated pedestrian counter : final report, February 2010.
DOT National Transportation Integrated Search
2010-02-01
Emerging sensor technologies accelerated the shift toward automatic pedestrian counting methods to : acquire reliable long-term data for transportation design, planning, and safety studies. Although a : number of commercial pedestrian sensors are ava...
Low-grade geothermal energy conversion by organic Rankine cycle turbine generator
NASA Astrophysics Data System (ADS)
Zarling, J. P.; Aspnes, J. D.
Results of a demonstration project which helped determine the feasibility of converting low-grade thermal energy in 49 C water into electrical energy via an organic Rankine cycle 2500 watt (electrical) turbine-generator are presented. The geothermal source which supplied the water is located in a rural Alaskan village. The reasons an organic Rankine cycle turbine-generator was investigated as a possible source of electric power in rural Alaska are: (1) high cost of operating diesel-electric units and their poor long-term reliability when high-quality maintenance is unavailable and (2) the extremely high level of long-term reliability reportedly attained by commercially available organic Rankine cycle turbines. Data is provided on the thermal and electrical operating characteristics of an experimental organic Rankine cycle turbine-generator operating at a uniquely low vaporizer temperature.
van der Maaten, Ernst; van der Maaten-Theunissen, Marieke; Buras, Allan; Scharnweber, Tobias; Simard, Sonia; Kaiser, Knut; Lorenz, Sebastian; Wilmking, Martin
2015-01-01
In this study, we explore the potential to reconstruct lake-level (and groundwater) fluctuations from tree-ring chronologies of black alder (Alnus glutinosa L.) for three study lakes in the Mecklenburg Lake District, northeastern Germany. As gauging records for lakes in this region are generally short, long-term reconstructions of lake-level fluctuations could provide valuable information on past hydrological conditions, which, in turn, are useful to assess dynamics of climate and landscape evolution. We selected black alder as our study species as alder typically thrives as riparian vegetation along lakeshores. For the study lakes, we tested whether a regional signal in lake-level fluctuations and in the growth of alder exists that could be used for long-term regional hydrological reconstructions, but found that local (i.e. site-specific) signals in lake level and tree-ring chronologies prevailed. Hence, we built lake/groundwater-level reconstruction models for the three study lakes individually. Two sets of models were considered based on (1) local tree-ring series of black alder, and (2) site-specific Standardized Precipitation Evapotranspiration Indices (SPEI). Although the SPEI-based models performed statistically well, we critically reflect on the reliability of these reconstructions, as SPEI cannot account for human influence. Tree-ring based reconstruction models, on the other hand, performed poor. Combined, our results suggest that, for our study area, long-term regional reconstructions of lake-level fluctuations that consider both recent and ancient (e.g., archaeological) wood of black alder seem extremely challenging, if not impossible. PMID:26317768
Rieger, Stefan B.; Pfau, Jennifer; Stieglitz, Thomas; Asplund, Maria; Ordonez, Juan S.
2016-01-01
There has been substantial progress over the last decade towards miniaturizing implantable microelectrodes for use in Active Implantable Medical Devices (AIMD). Compared to the rapid development and complexity of electrode miniaturization, methods to monitor and assess functional integrity and electrical functionality of these electrodes, particularly during long term stimulation, have not progressed to the same extent. Evaluation methods that form the gold standard, such as stimulus pulse testing, cyclic voltammetry and electrochemical impedance spectroscopy, are either still bound to laboratory infrastructure (impractical for long term in vivo experiments) or deliver no comprehensive insight into the material’s behaviour. As there is a lack of cost effective and practical predictive measures to understand long term electrode behaviour in vivo, material investigations need to be performed after explantation of the electrodes. We propose the analysis of the electrode and its environment in situ, to better understand and correlate the effects leading to electrode failure. The derived knowledge shall eventually lead to improved electrode designs, increased electrode functionality and safety in clinical applications. In this paper, the concept, design and prototyping of a sensor framework used to analyse the electrode’s behaviour and to monitor diverse electrode failure mechanisms, even during stimulation pulses, is presented. We focused on the electronic circuitry and data acquisition techniques required for a conceptual multi-sensor system. Functionality of single modules and a prototype framework have been demonstrated, but further work is needed to convert the prototype system into an implantable device. In vitro studies will be conducted first to verify sensor performance and reliability. PMID:28042815
Accurate Determination of Soluble Axl by Enzyme-Linked Immunosorbent Assay.
Dengler, Mirko; Huber, Heidemarie; Müller, Christian J; Zellmer, Angela; Rauch, Peter; Mikulits, Wolfgang
2016-11-01
Levels of soluble Axl (sAxl) are routinely assessed in human sera by sandwich enzyme-linked immunosorbent assay (ELISA). Although sAxl values are suggested to diagnose different types of disorders, no uniform ELISA method is available, allowing the reliable interassay comparison between results. Furthermore, little is known about the stability of sAxl under storage conditions, which is a relevant parameter for biomedical trials. The evaluation of sAxl stability under various stress conditions and the determination of proper conditions to use the sAxl ELISA for routine clinical applications are of great interest. In this study, serum samples were subjected to freeze-thaw cycles and incubation at different temperatures to analyze the stability of sAxl by ELISA. Dilution and spike-in experiments were carried out to examine the impact of serum and diluent components on the ELISA performance. Various diluents and media were employed to resolve masking effects of the serum. The assay components were further optimized for long-term usability by treatment with stabilizers and validation under temperature stress. Indeed, sAxl showed long-term stability in serum during freeze-thaw cycles and incubation under temperature stress conditions. The dilution experiments revealed that unknown components in the serum caused masking effects that can be reduced by proper dilutions. The assay performance was further increased by using a standardized buffer system to dilute serum samples. Stabilization of coated plates and of streptavidin-horseradish peroxidase allowed long-term storage for up to 6 months. In sum, our data demonstrate proper ELISA conditions, allowing the accurate analysis of sAxl levels in human serum.
Braunschmidt, Brigitte; Müller, Gerhard; Jukic-Puntigam, Margareta; Steininger, Alfred
2013-01-01
Incontinence-associated dermatitis (IAD) is the clinical manifestation of moisture related skin damage (Beeckman, Woodward, & Gray, 2011). Valid assessment instruments are needed for risk assessment and classification of IAD. Aim of the quantitative-descriptive cross-sectional study was to determine the inter-rater reliability of the item scores of the German Incontinence Associated Dermatitis Intervention Tool (IADIT-D) between two independent assessors of nursing home residents (n = 381) in long-term care facilities. The 19 pairs of assessors consisted of registered nurses. The data analysis was computed first with the calculation of the total percentage of agreement. Because this value is not randomly adjusted, the calculation of the Kappa-coefficients and AC1-Statistic was done as well. The total percentage of the inter-rater agreement was 84% (n = 319). In a second step of analysis, the calculation of all items determined high (kappa = .70) and very high agreement (AC1 = .83) levels, respectively. For the risk assessment (kappa = .82; AC1 = .94), the values amounted to very high agreement levels and for the classification (kappa(w) = .70; AC1 = .76) to high agreement levels. The high to very high agreement values of IADIT-D demonstrate that the items can be regarded as stable in regards to the inter-rater reliability for the use in long-term care facilities. In addition, further validation studies are needed.
A medical record review for functional somatic symptoms in children.
Rask, Charlotte Ulrikka; Borg, Carsten; Søndergaard, Charlotte; Schulz-Pedersen, Søren; Thomsen, Per Hove; Fink, Per
2010-04-01
The objectives of this study were to develop and test a systematic medical record review for functional somatic symptoms (FSSs) in paediatric patients and to estimate the inter-rater reliability of paediatricians' recognition of FSSs and their associated impairments while using this method. We developed the Medical Record Review for Functional Somatic Symptoms in Children (MRFC) for retrospective medical record review. Described symptoms were categorised as probably, definitely, or not FSSs. FSS-associated impairment was also determined. Three paediatricians performed the MRFC on the medical records of 54 children with a diagnosed, well-defined physical disease and 59 with 'symptom' diagnoses. The inter-rater reliabilities of the recognition and associated impairment of FSSs were tested on 20 of these records. The MRFC allowed identification of subgroups of children with multisymptomatic FSSs, long-term FSSs, and/or impairing FSSs. The FSS inter-rater reliability was good (combined kappa=0.69) but only fair as far as associated impairment was concerned (combined kappa=0.29). In the hands of skilled paediatricians, the MRFC is a reliable method for identifying paediatric patients with diverse types of FSSs for clinical research. However, additional information is needed for reliable judgement of impairment. The method may also prove useful in clinical practice. Copyright 2010 Elsevier Inc. All rights reserved.
Operational present status and reliability analysis of the upgraded EAST cryogenic system
NASA Astrophysics Data System (ADS)
Zhou, Z. W.; Y Zhang, Q.; Lu, X. F.; Hu, L. B.; Zhu, P.
2017-12-01
Since the first commissioning in 2005, the cryogenic system for EAST (Experimental Advanced Superconducting Tokamak) has been cooled down and warmed up for thirteen experimental campaigns. In order to promote the refrigeration efficiencies and reliability, the EAST cryogenic system was upgraded gradually with new helium screw compressors and new dynamic gas bearing helium turbine expanders with eddy current brake to improve the original poor mechanical and operational performance from 2012 to 2015. Then the totally upgraded cryogenic system was put into operation in the eleventh cool-down experiment, and has been operated for the latest several experimental campaigns. The upgraded system has successfully coped with various normal operational modes during cool-down and 4.5 K steady-state operation under pulsed heat load from the tokamak as well as the abnormal fault modes including turbines protection stop. In this paper, the upgraded EAST cryogenic system including its functional analysis and new cryogenic control networks will be presented in detail. Also, its operational present status in the latest cool-down experiments will be presented and the system reliability will be analyzed, which shows a high reliability and low fault rate after upgrade. In the end, some future necessary work to meet the higher reliability requirement for future uninterrupted long-term experimental operation will also be proposed.
Temporal variations in the potential hydrological performance of extensive green roof systems
NASA Astrophysics Data System (ADS)
De-Ville, Simon; Menon, Manoj; Stovin, Virginia
2018-03-01
Existing literature provides contradictory information about variation in potential green roof hydrological performance over time. This study has evaluated a long-term hydrological monitoring record from a series of extensive green roof test beds to identify long-term evolutions and sub-annual (seasonal) variations in potential hydrological performance. Monitoring of nine differently-configured extensive green roof test beds took place over a period of 6 years in Sheffield, UK. Long-term evolutions and sub-annual trends in maximum potential retention performance were identified through physical monitoring of substrate field capacity over time. An independent evaluation of temporal variations in detention performance was undertaken through the fitting of reservoir-routing model parameters. Aggregation of the resulting retention and detention variations permitted the prediction of extensive green roof hydrological performance in response to a 1-in-30-year 1-h summer design storm for Sheffield, UK, which facilitated the comparison of multi and sub-annual hydrological performance variations. Sub-annual (seasonal) variation was found to be significantly greater than long-term evolution. Potential retention performance increased by up to 12% after 5-years, whilst the maximum sub-annual variation in potential retention was 27%. For vegetated roof configurations, a 4% long-term improvement was observed for detention performance, compared to a maximum 63% sub-annual variation. Consistent long-term reductions in detention performance were observed in unvegetated roof configurations, with a non-standard expanded-clay substrate experiencing a 45% reduction in peak attenuation over 5-years. Conventional roof configurations exhibit stable long-term hydrological performance, but are nonetheless subject to sub-annual variation.
Boisvert, Isabelle; McMahon, Catherine M.; Dowell, Richard C.; Lyxell, Björn
2015-01-01
In many countries, a single cochlear implant is offered as a treatment for a bilateral hearing loss. In cases where there is asymmetry in the amount of sound deprivation between the ears, there is a dilemma in choosing which ear should be implanted. In many clinics, the choice of ear has been guided by an assumption that the reorganisation of the auditory pathways caused by longer duration of deafness in one ear is associated with poorer implantation outcomes for that ear. This assumption, however, is mainly derived from studies of early childhood deafness. This study compared outcomes following implantation of the better or poorer ear in cases of long-term hearing asymmetries. Audiological records of 146 adults with bilateral hearing loss using a single hearing aid were reviewed. The unaided ear had 15 to 72 years of unaided severe to profound hearing loss before unilateral cochlear implantation. 98 received the implant in their long-term sound-deprived ear. A multiple regression analysis was conducted to assess the relative contribution of potential predictors to speech recognition performance after implantation. Duration of bilateral significant hearing loss and the presence of a prelingual hearing loss explained the majority of variance in speech recognition performance following cochlear implantation. For participants with postlingual hearing loss, similar outcomes were obtained by implanting either ear. With prelingual hearing loss, poorer outcomes were obtained when implanting the long-term sound-deprived ear, but the duration of the sound deprivation in the implanted ear did not reliably predict outcomes. Contrary to an apparent clinical consensus, duration of sound deprivation in one ear has limited value in predicting speech recognition outcomes of cochlear implantation in that ear. Outcomes of cochlear implantation are more closely related to the period of time for which the brain is deprived of auditory stimulation from both ears. PMID:26043227
[Laparoscopic sterilization with electrocautery: complications and reliability (author's transl)].
Bänninger, U; Kunz, J; Schreiner, W E
1979-05-01
1084 laparoscopic sterilizations were evaluated in a retrospective study at the Universitäts-Frauenklinik Zürich. The operative and early postoperative complications and the reliability of the method were analysed and compared to the results in the literature. Based on a cumulative statistical analysis 0,5% intraoperative complications required laparotomy, the main indications being haemorrhages and bowel injuries. Failed attempts were encountered in one of 150 patients, the main causes of which were adhaesions and difficulties at establishing pneumoperitoneum. The failure rate of the laparoscopic electrocoagulation of the fallopian tube after a long-term follow-up was about 0,5%, 20--25% of these were ectopic pregnancies. The transection of the fallopian tubes did not diminish the pregnancy rate, but the risk of bleeding was considerably higher with this technic. Concurrently performed therapeutic abortion or preceeeding laparotomy did not increase the operative complication rate.
Nakhutina, L; Pramataris, P; Morrison, C; Devinsky, O; Barr, W B
2010-01-01
The Rey-Osterreith Complex Figure (ROCF) is commonly used in evaluations of patients undergoing epilepsy surgery. We assessed test-retest performance on ROCF in 30 partial epilepsy patients (mean interval = 33.7 months) to derive reliable change indices (RCIs) and regression-based measures for change. ROCF reproductions were rescored by three raters (IRR Copy: 0.963; Delayed Recall: 0.986). The derived adjusted RC (90% CI) cutoff values for the ROCF Copy were (
Strus, Mark C; Chiaramonti, Ann N; Kim, Young Lae; Jung, Yung Joon; Keller, Robert R
2011-07-01
We investigate the electrical reliability of nanoscale lines of highly aligned, networked, metallic/semiconducting single-walled carbon nanotubes (SWCNTs) fabricated through a template-based fluidic assembly process. We find that these SWCNT networks can withstand DC current densities larger than 10 MA cm(-2) for several hours and, in some cases, several days. We develop test methods that show that the degradation rate, failure predictability and total device lifetime can be linked to the initial resistance. Scanning electron and transmission electron microscopy suggest that fabrication variability plays a critical role in the rate of degradation, and we offer an empirical method of quickly determining the long-term performance of a network. We find that well-fabricated lines subject to constant electrical stress show a linear accumulation of damage reminiscent of electromigration in metallic interconnects, and we explore the underlying physical mechanisms that could cause such behavior.
Long-term bridge performance high priority bridge performance issues.
DOT National Transportation Integrated Search
2014-10-01
Bridge performance is a multifaceted issue involving performance of materials and protective systems, : performance of individual components of the bridge, and performance of the structural system as a whole. The : Long-Term Bridge Performance (LTBP)...
Thermoelectric Outer Planets Spacecraft (TOPS)
NASA Technical Reports Server (NTRS)
1973-01-01
The research and advanced development work is reported on a ballistic-mode, outer planet spacecraft using radioisotope thermoelectric generator (RTG) power. The Thermoelectric Outer Planet Spacecraft (TOPS) project was established to provide the advanced systems technology that would allow the realistic estimates of performance, cost, reliability, and scheduling that are required for an actual flight mission. A system design of the complete RTG-powered outer planet spacecraft was made; major technical innovations of certain hardware elements were designed, developed, and tested; and reliability and quality assurance concepts were developed for long-life requirements. At the conclusion of its active phase, the TOPS Project reached its principal objectives: a development and experience base was established for project definition, and for estimating cost, performance, and reliability; an understanding of system and subsystem capabilities for successful outer planets missions was achieved. The system design answered long-life requirements with massive redundancy, controlled by on-board analysis of spacecraft performance data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milligan, Michael; Frew, Bethany A.; Bloom, Aaron
This paper discusses challenges that relate to assessing and properly incentivizing the resources necessary to ensure a reliable electricity system with growing penetrations of variable generation (VG). The output of VG (primarily wind and solar generation) varies over time and cannot be predicted precisely. Therefore, the energy from VG is not always guaranteed to be available at times when it is most needed. This means that its contribution towards resource adequacy can be significantly less than the contribution from traditional resources. Variable renewable resources also have near-zero variable costs, and with production-based subsidies they may even have negative offer costs.more » Because variable costs drive the spot price of energy, this can lead to reduced prices, sales, and therefore revenue for all resources within the energy market. The characteristics of VG can also result in increased price volatility as well as the need for more flexibility in the resource fleet in order to maintain system reliability. Furthermore, we explore both traditional and evolving electricity market designs in the United States that aim to ensure resource adequacy and sufficient revenues to recover costs when those resources are needed for long-term reliability. We also investigate how reliability needs may be evolving and discuss how VG may affect future electricity market designs.« less
Milligan, Michael; Frew, Bethany A.; Bloom, Aaron; ...
2016-03-22
This paper discusses challenges that relate to assessing and properly incentivizing the resources necessary to ensure a reliable electricity system with growing penetrations of variable generation (VG). The output of VG (primarily wind and solar generation) varies over time and cannot be predicted precisely. Therefore, the energy from VG is not always guaranteed to be available at times when it is most needed. This means that its contribution towards resource adequacy can be significantly less than the contribution from traditional resources. Variable renewable resources also have near-zero variable costs, and with production-based subsidies they may even have negative offer costs.more » Because variable costs drive the spot price of energy, this can lead to reduced prices, sales, and therefore revenue for all resources within the energy market. The characteristics of VG can also result in increased price volatility as well as the need for more flexibility in the resource fleet in order to maintain system reliability. Furthermore, we explore both traditional and evolving electricity market designs in the United States that aim to ensure resource adequacy and sufficient revenues to recover costs when those resources are needed for long-term reliability. We also investigate how reliability needs may be evolving and discuss how VG may affect future electricity market designs.« less
CRAX/Cassandra Reliability Analysis Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, D.
1999-02-10
Over the past few years Sandia National Laboratories has been moving toward an increased dependence on model- or physics-based analyses as a means to assess the impact of long-term storage on the nuclear weapons stockpile. These deterministic models have also been used to evaluate replacements for aging systems, often involving commercial off-the-shelf components (COTS). In addition, the models have been used to assess the performance of replacement components manufactured via unique, small-lot production runs. In either case, the limited amount of available test data dictates that the only logical course of action to characterize the reliability of these components ismore » to specifically consider the uncertainties in material properties, operating environment etc. within the physics-based (deterministic) model. This not only provides the ability to statistically characterize the expected performance of the component or system, but also provides direction regarding the benefits of additional testing on specific components within the system. An effort was therefore initiated to evaluate the capabilities of existing probabilistic methods and, if required, to develop new analysis methods to support the inclusion of uncertainty in the classical design tools used by analysts and design engineers at Sandia. The primary result of this effort is the CMX (Cassandra Exoskeleton) reliability analysis software.« less
Medical reliable network using concatenated channel codes through GSM network.
Ahmed, Emtithal; Kohno, Ryuji
2013-01-01
Although the 4(th) generation (4G) of global mobile communication network, i.e. Long Term Evolution (LTE) coexisting with the 3(rd) generation (3G) has successfully started; the 2(nd) generation (2G), i.e. Global System for Mobile communication (GSM) still playing an important role in many developing countries. Without any other reliable network infrastructure, GSM can be applied for tele-monitoring applications, where high mobility and low cost are necessary. A core objective of this paper is to introduce the design of a more reliable and dependable Medical Network Channel Code system (MNCC) through GSM Network. MNCC design based on simple concatenated channel code, which is cascade of an inner code (GSM) and an extra outer code (Convolution Code) in order to protect medical data more robust against channel errors than other data using the existing GSM network. In this paper, the MNCC system will provide Bit Error Rate (BER) equivalent to the BER for medical tele monitoring of physiological signals, which is 10(-5) or less. The performance of the MNCC has been proven and investigated using computer simulations under different channels condition such as, Additive White Gaussian Noise (AWGN), Rayleigh noise and burst noise. Generally the MNCC system has been providing better performance as compared to GSM.
Probabilistic Assessment of High-Throughput Wireless Sensor Networks
Kim, Robin E.; Mechitov, Kirill; Sim, Sung-Han; Spencer, Billie F.; Song, Junho
2016-01-01
Structural health monitoring (SHM) using wireless smart sensors (WSS) has the potential to provide rich information on the state of a structure. However, because of their distributed nature, maintaining highly robust and reliable networks can be challenging. Assessing WSS network communication quality before and after finalizing a deployment is critical to achieve a successful WSS network for SHM purposes. Early studies on WSS network reliability mostly used temporal signal indicators, composed of a smaller number of packets, to assess the network reliability. However, because the WSS networks for SHM purpose often require high data throughput, i.e., a larger number of packets are delivered within the communication, such an approach is not sufficient. Instead, in this study, a model that can assess, probabilistically, the long-term performance of the network is proposed. The proposed model is based on readily-available measured data sets that represent communication quality during high-throughput data transfer. Then, an empirical limit-state function is determined, which is further used to estimate the probability of network communication failure. Monte Carlo simulation is adopted in this paper and applied to a small and a full-bridge wireless networks. By performing the proposed analysis in complex sensor networks, an optimized sensor topology can be achieved. PMID:27258270
Financial forecasts accuracy in Brazil's social security system.
Silva, Carlos Patrick Alves da; Puty, Claudio Alberto Castelo Branco; Silva, Marcelino Silva da; Carvalho, Solon Venâncio de; Francês, Carlos Renato Lisboa
2017-01-01
Long-term social security statistical forecasts produced and disseminated by the Brazilian government aim to provide accurate results that would serve as background information for optimal policy decisions. These forecasts are being used as support for the government's proposed pension reform that plans to radically change the Brazilian Constitution insofar as Social Security is concerned. However, the reliability of official results is uncertain since no systematic evaluation of these forecasts has ever been published by the Brazilian government or anyone else. This paper aims to present a study of the accuracy and methodology of the instruments used by the Brazilian government to carry out long-term actuarial forecasts. We base our research on an empirical and probabilistic analysis of the official models. Our empirical analysis shows that the long-term Social Security forecasts are systematically biased in the short term and have significant errors that render them meaningless in the long run. Moreover, the low level of transparency in the methods impaired the replication of results published by the Brazilian Government and the use of outdated data compromises forecast results. In the theoretical analysis, based on a mathematical modeling approach, we discuss the complexity and limitations of the macroeconomic forecast through the computation of confidence intervals. We demonstrate the problems related to error measurement inherent to any forecasting process. We then extend this exercise to the computation of confidence intervals for Social Security forecasts. This mathematical exercise raises questions about the degree of reliability of the Social Security forecasts.
Financial forecasts accuracy in Brazil’s social security system
2017-01-01
Long-term social security statistical forecasts produced and disseminated by the Brazilian government aim to provide accurate results that would serve as background information for optimal policy decisions. These forecasts are being used as support for the government’s proposed pension reform that plans to radically change the Brazilian Constitution insofar as Social Security is concerned. However, the reliability of official results is uncertain since no systematic evaluation of these forecasts has ever been published by the Brazilian government or anyone else. This paper aims to present a study of the accuracy and methodology of the instruments used by the Brazilian government to carry out long-term actuarial forecasts. We base our research on an empirical and probabilistic analysis of the official models. Our empirical analysis shows that the long-term Social Security forecasts are systematically biased in the short term and have significant errors that render them meaningless in the long run. Moreover, the low level of transparency in the methods impaired the replication of results published by the Brazilian Government and the use of outdated data compromises forecast results. In the theoretical analysis, based on a mathematical modeling approach, we discuss the complexity and limitations of the macroeconomic forecast through the computation of confidence intervals. We demonstrate the problems related to error measurement inherent to any forecasting process. We then extend this exercise to the computation of confidence intervals for Social Security forecasts. This mathematical exercise raises questions about the degree of reliability of the Social Security forecasts. PMID:28859172
Carbon dioxide removal and the futures market
NASA Astrophysics Data System (ADS)
Coffman, D.'Maris; Lockley, Andrew
2017-01-01
Futures contracts are exchange-traded financial instruments that enable parties to fix a price in advance, for later performance on a contract. Forward contracts also entail future settlement, but they are traded directly between two parties. Futures and forwards are used in commodities trading, as producers seek financial security when planning production. We discuss the potential use of futures contracts in Carbon Dioxide Removal (CDR) markets; concluding that they have one principal advantage (near-term price security to current polluters), and one principal disadvantage (a combination of high price volatility and high trade volume means contracts issued by the private sector may cause systemic economic risk). Accordingly, we note the potential for the development of futures markets in CDR, but urge caution about the prospects for market failure. In particular, we consider the use of regulated markets: to ensure contracts are more reliable, and that moral hazard is minimised. While regulation offers increased assurances, we identify major insufficiencies with this approach—finding it generally inadequate. In conclusion, we suggest that only governments can realistically support long-term CDR futures markets. We note existing long-term CDR plans by governments, and suggest the use of state-backed futures for supporting these assurances.
Difficulties in tracking the long-term global trend in tropical forest area.
Grainger, Alan
2008-01-15
The long-term trend in tropical forest area receives less scrutiny than the tropical deforestation rate. We show that constructing a reliable trend is difficult and evidence for decline is unclear, within the limits of errors involved in making global estimates. A time series for all tropical forest area, using data from Forest Resources Assessments (FRAs) of the United Nations Food and Agriculture Organization, is dominated by three successively corrected declining trends. Inconsistencies between these trends raise questions about their reliability, especially because differences seem to result as much from errors as from changes in statistical design and use of new data. A second time series for tropical moist forest area shows no apparent decline. The latter may be masked by the errors involved, but a "forest return" effect may also be operating, in which forest regeneration in some areas offsets deforestation (but not biodiversity loss) elsewhere. A better monitoring program is needed to give a more reliable trend. Scientists who use FRA data should check how the accuracy of their findings depends on errors in the data.
High temperature circuit breaker
NASA Technical Reports Server (NTRS)
Edwards, R. N.; Travis, E. F.
1970-01-01
Alternating current circuit breaker is suitable for reliable long-term service at 1000 deg F in the vacuum conditions of outer space. Construction materials are resistant to nuclear radiation and vacuum welding. Service test conditions and results are given.
Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing - Part 2
NASA Technical Reports Server (NTRS)
Montgomery, Eliza L.; Calle, Luz Marina; Curran, Jerome C.; Kolody, Mark R.
2012-01-01
Evaluation of metals to predict service life of metal-based structures in corrosive environments has long relied on atmospheric exposure test sites. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions similar to those of the corrosive environment. Their reliability to correlate to atmospheric exposure test results is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated corrosion testing has yet to be universally accepted as a useful tool in predicting the long-term service life of a metal, despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard, and their use is crucial, a method that correlates timescales from accelerated testing to atmospheric exposure would be very valuable. This paper presents work that began with the characterization of the atmospheric environment at the Kennedy Space Center (KSC) Beachside Corrosion Test Site. The chemical changes that occur on low carbon steel, during atmospheric and accelerated corrosion conditions, were investigated using surface chemistry analytical methods. The corrosion rates and behaviors of panels subjected to long-term and accelerated corrosion conditions, involving neutral salt fog and alternating seawater spray, were compared to identify possible timescale correlations between accelerated and long-term corrosion performance. The results, as well as preliminary findings on the correlation investigation, are presented.
NASA Astrophysics Data System (ADS)
To, Albert C.; Liu, Wing Kam; Olson, Gregory B.; Belytschko, Ted; Chen, Wei; Shephard, Mark S.; Chung, Yip-Wah; Ghanem, Roger; Voorhees, Peter W.; Seidman, David N.; Wolverton, Chris; Chen, J. S.; Moran, Brian; Freeman, Arthur J.; Tian, Rong; Luo, Xiaojuan; Lautenschlager, Eric; Challoner, A. Dorian
2008-09-01
Microsystems have become an integral part of our lives and can be found in homeland security, medical science, aerospace applications and beyond. Many critical microsystem applications are in harsh environments, in which long-term reliability needs to be guaranteed and repair is not feasible. For example, gyroscope microsystems on satellites need to function for over 20 years under severe radiation, thermal cycling, and shock loading. Hence a predictive-science-based, verified and validated computational models and algorithms to predict the performance and materials integrity of microsystems in these situations is needed. Confidence in these predictions is improved by quantifying uncertainties and approximation errors. With no full system testing and limited sub-system testings, petascale computing is certainly necessary to span both time and space scales and to reduce the uncertainty in the prediction of long-term reliability. This paper presents the necessary steps to develop predictive-science-based multiscale modeling and simulation system. The development of this system will be focused on the prediction of the long-term performance of a gyroscope microsystem. The environmental effects to be considered include radiation, thermo-mechanical cycling and shock. Since there will be many material performance issues, attention is restricted to creep resulting from thermal aging and radiation-enhanced mass diffusion, material instability due to radiation and thermo-mechanical cycling and damage and fracture due to shock. To meet these challenges, we aim to develop an integrated multiscale software analysis system that spans the length scales from the atomistic scale to the scale of the device. The proposed software system will include molecular mechanics, phase field evolution, micromechanics and continuum mechanics software, and the state-of-the-art model identification strategies where atomistic properties are calibrated by quantum calculations. We aim to predict the long-term (in excess of 20 years) integrity of the resonator, electrode base, multilayer metallic bonding pads, and vacuum seals in a prescribed mission. Although multiscale simulations are efficient in the sense that they focus the most computationally intensive models and methods on only the portions of the space time domain needed, the execution of the multiscale simulations associated with evaluating materials and device integrity for aerospace microsystems will require the application of petascale computing. A component-based software strategy will be used in the development of our massively parallel multiscale simulation system. This approach will allow us to take full advantage of existing single scale modeling components. An extensive, pervasive thrust in the software system development is verification, validation, and uncertainty quantification (UQ). Each component and the integrated software system need to be carefully verified. An UQ methodology that determines the quality of predictive information available from experimental measurements and packages the information in a form suitable for UQ at various scales needs to be developed. Experiments to validate the model at the nanoscale, microscale, and macroscale are proposed. The development of a petascale predictive-science-based multiscale modeling and simulation system will advance the field of predictive multiscale science so that it can be used to reliably analyze problems of unprecedented complexity, where limited testing resources can be adequately replaced by petascale computational power, advanced verification, validation, and UQ methodologies.
Median of patient results as a tool for assessment of analytical stability.
Jørgensen, Lars Mønster; Hansen, Steen Ingemann; Petersen, Per Hyltoft; Sölétormos, György
2015-06-15
In spite of the well-established external quality assessment and proficiency testing surveys of analytical quality performance in laboratory medicine, a simple tool to monitor the long-term analytical stability as a supplement to the internal control procedures is often needed. Patient data from daily internal control schemes was used for monthly appraisal of the analytical stability. This was accomplished by using the monthly medians of patient results to disclose deviations from analytical stability, and by comparing divergences with the quality specifications for allowable analytical bias based on biological variation. Seventy five percent of the twenty analytes achieved on two COBASs INTEGRA 800 instruments performed in accordance with the optimum and with the desirable specifications for bias. Patient results applied in analytical quality performance control procedures are the most reliable sources of material as they represent the genuine substance of the measurements and therefore circumvent the problems associated with non-commutable materials in external assessment. Patient medians in the monthly monitoring of analytical stability in laboratory medicine are an inexpensive, simple and reliable tool to monitor the steadiness of the analytical practice. Copyright © 2015 Elsevier B.V. All rights reserved.
Performance test results of 80 K centrifugal compressor for helium refrigerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asakura, H.; Kato, D.; Saji, N.
1994-12-31
The authors have developed a completely oil-free compressor used for the highly reliable helium refrigeration system for a superconducting generator and carried out performance tests under actual condition. The compressor is designed to achieve a pressure ratio of 8 with only 4 stages by cooling the compressor inlet at 80 K with liquid nitrogen, thus acquiring high reliability of long-term maintenance-free operation together with the use of magnetic bearings for oil-free operation. The compressor at each stage is independently driven by a 25 kW built-in motor at the speed of 100,000 rpm, with the power supplied by a variable frequencymore » inverter. The performance test was carried out at each stage, by incorporating the compressor in the closed loop test equipment using helium gas. It was recognized from the test results that the specified pressure ratio of each stage was achieved at the speed below the rated one of 100,000 rpm. It was found that each stage of the compressor has a flat characteristics of adiabatic efficiency over the wide flow range. The mechanical rotation characteristics at low temperatures was also confirmed to be sufficiently stable.« less
On the reliability of computed chaotic solutions of non-linear differential equations
NASA Astrophysics Data System (ADS)
Liao, Shijun
2009-08-01
A new concept, namely the critical predictable time Tc, is introduced to give a more precise description of computed chaotic solutions of non-linear differential equations: it is suggested that computed chaotic solutions are unreliable and doubtable when t > Tc. This provides us a strategy to detect reliable solution from a given computed result. In this way, the computational phenomena, such as computational chaos (CC), computational periodicity (CP) and computational prediction uncertainty, which are mainly based on long-term properties of computed time-series, can be completely avoided. Using this concept, the famous conclusion `accurate long-term prediction of chaos is impossible' should be replaced by a more precise conclusion that `accurate prediction of chaos beyond the critical predictable time Tc is impossible'. So, this concept also provides us a timescale to determine whether or not a particular time is long enough for a given non-linear dynamic system. Besides, the influence of data inaccuracy and various numerical schemes on the critical predictable time is investigated in details by using symbolic computation software as a tool. A reliable chaotic solution of Lorenz equation in a rather large interval 0 <= t < 1200 non-dimensional Lorenz time units is obtained for the first time. It is found that the precision of the initial condition and the computed data at each time step, which is mathematically necessary to get such a reliable chaotic solution in such a long time, is so high that it is physically impossible due to the Heisenberg uncertainty principle in quantum physics. This, however, provides us a so-called `precision paradox of chaos', which suggests that the prediction uncertainty of chaos is physically unavoidable, and that even the macroscopical phenomena might be essentially stochastic and thus could be described by probability more economically.
Evaluation of the durability of composite tidal turbine blades.
Davies, Peter; Germain, Grégory; Gaurier, Benoît; Boisseau, Amélie; Perreux, Dominique
2013-02-28
The long-term reliability of tidal turbines is critical if these structures are to be cost effective. Optimized design requires a combination of material durability models and structural analyses. Composites are a natural choice for turbine blades, but there are few data available to predict material behaviour under coupled environmental and cycling loading. The present study addresses this problem, by introducing a multi-level framework for turbine blade qualification. At the material scale, static and cyclic tests have been performed, both in air and in sea water. The influence of ageing in sea water on fatigue performance is then quantified, and much lower fatigue lives are measured after ageing. At a higher level, flume tank tests have been performed on three-blade tidal turbines. Strain gauging of blades has provided data to compare with numerical models.
Johnson, L C; Chernik, D A; Sateia, M J
1990-08-01
A review of the published literature reveals many unanswered questions regarding the effects of sedative-hypnotics on sleep, performance, and mood. The relationship between plasma half-life and hypnotic efficacy is also not clear. A randomized, double-blind, parallel-groups, multicenter study was designed to examine sleep, performance, and mood in patients with insomnia. A large, heterogeneous sample of patients with a history of benzodiazepine use for chronic insomnia was chosen to reflect the adult population for which sedative-hypnotics are often prescribed and to ensure statistical reliability. Although the major focus of the current study was on the effects of two benzodiazepine hypnotics on performance, this study also provided information on the following important issues: (1) effect of dose level; (2) short-versus long-term administration; and (3) significance of plasma half-life as it relates to hypnotic efficacy.
Long-Term Monitoring Research Needs: A DOE Perspective
NASA Astrophysics Data System (ADS)
Moore, B.; Davis, C. B.
2002-05-01
The U.S. Department of Energy's Office of Environmental Management is responsible for dealing with the nation's legacy of Cold War radioactive and hazardous waste and contamination. Major efforts are underway to deal with this legacy; these are expected to last up to decades and cost up to billions of dollars at some sites. At all sites, however, active remediation must eventually cease; if hazards then remain, the site must enter into a long-term stewardship mode. In this talk we discuss aspects of long-term monitoring pertinent to DOE sites, focusing on challenges to be faced, specific goals or targets to be met, and research needs to be addressed in order to enable DOE to meet its long-term stewardship obligations. DOE LTM research needs fall into three major categories: doing what we can do now much more efficiently; doing things we cannot do now; and proving the validity of our monitoring programs. Given the enormity of the DOE obligations, it will be highly desirable to develop much more efficient monitoring paradigms. Doing so will demand developing autonomous, remote monitoring networks of in situ sensors capable of replacing (or at least supplementing to a large extent) conventional groundwater and soil gas sampling and analysis programs. The challenges involved range from basic science (e.g., inventing in situ sensors for TCE that do not demand routine maintenance) to engineering (attaining superior reliability in data reporting in remote networks) to ergonomics (developing decent ways of selecting and presenting the "right" information from the monitoring network) to regulatory affairs (presenting convincing evidence that the more efficient systems actually provide superior monitoring). We explore these challenges in some detail, focusing on the "long" in long-term monitoring as it applies to DOE sites. Monitoring system performance validation and, ultimately, regulator and stakeholder acceptance of site closure and long-term stewardship plans depend critically on the validity and uncertainty in models used to predict contaminant fate and transport. This is an area of active research at the present time. We survey joint research initiatives in this area involving DOE along with USGS, U.S. EPA, U.S. NRC, and U.S. DOA and non-Federal collaborators, and explore their potential for furthering DOE long-term monitoring needs and objectives.
Validation of FIBER 3.0 for tolerant hardwood stands in Ontario
Jacek Bankowski; Daniel C. Dey; Murray Woods; Jim Rice; Eric Boysen; Brian Batchelor; Roj Miller
1995-01-01
Growth and yield projections aid foresters in assessing timber management opportunities and in making management decisions. With these uses, questions arise about the reliability and limits of growth and yield simulators. Using long-term studies of hardwood stands in Ontario the growth simulator FIBER 3.0 has been tested. Short-term (5 years) projections of stand...
Validation of NE-TWIGS for tolerant hardwood stands in Ontario
Jacek Bankowski; Daniel C. Dey; Eric Boysen; Murray Woods; Jim Rice
1996-01-01
The individual-tree, distance-independent stand growth simulator NE-TWIGS has been tested for Ontario's tolerant hardwood stands using data from long-term permanent sample plots. NE-TWIGS provides reliable short-term (5-year) predictions of stand basal area (modelling efficiency from 77% to 99%), but in longer projections the efficiency of the model drops...
Lin, Jesun; Hsiao, Chih-Tung; Glen, Robert; Pai, Jar-Yuan; Zeng, Sin-Huei
2014-06-01
To investigate the psychometric properties and relationships of perceived service quality, perceived value and overall satisfaction for residents with respect to their long-term care institutions. The five-point Likert scale questionnaire administered through facetoface interviews. Fourteen long-term care institutions located in central and southern Taiwan stratified according to services and accommodation population. One hundred and eighty long-term institutional care residents. Perceived service quality (the SERVPERF model), perceived value and overall satisfaction (models based on the literature on perceived value and satisfaction). Student's t-test on institutional location shows a significant difference between overall satisfaction for central and southern institution long-term care recipients. The correlation test revealed that the higher a resident's level of education, the higher the scores for perceived value. The factor loading results of confirmation factor analysis show acceptable levels of reliability and index-of-model fits for perceived service, perceived value and overall satisfaction. In addition, the results suggest that an additional construct, a positive attitude (happiness of outlook) towards long-term care institutions, is also an important factor in residents' overall satisfaction. The primary goal of long-term institutional care policy in Taiwan, as in other countries, is to provide residents with practical, cost-effective but high-quality care. On the basis of the results of in-depth interviews with long-term institutional care residents, this study suggests long-term care institutions arrange more family visit days to increase the accessibility and interaction of family and residents and thereby increase the happiness of outlook of the residents. © 2012 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Ramesham, Rajeshuni
2012-03-01
Ceramic column grid array (CCGA) packages have been increasing in use based on their advantages such as high interconnect density, very good thermal and electrical performances, compatibility with standard surfacemount packaging assembly processes, and so on. CCGA packages are used in space applications such as in logic and microprocessor functions, telecommunications, payload electronics, and flight avionics. As these packages tend to have less solder joint strain relief than leaded packages or more strain relief over lead-less chip carrier packages, the reliability of CCGA packages is very important for short-term and long-term deep space missions. We have employed high density CCGA 1152 and 1272 daisy chained electronic packages in this preliminary reliability study. Each package is divided into several daisy-chained sections. The physical dimensions of CCGA1152 package is 35 mm x 35 mm with a 34 x 34 array of columns with a 1 mm pitch. The dimension of the CCGA1272 package is 37.5 mm x 37.5 mm with a 36 x 36 array with a 1 mm pitch. The columns are made up of 80% Pb/20%Sn material. CCGA interconnect electronic package printed wiring polyimide boards have been assembled and inspected using non-destructive x-ray imaging techniques. The assembled CCGA boards were subjected to extreme temperature thermal atmospheric cycling to assess their reliability for future deep space missions. The resistance of daisy-chained interconnect sections were monitored continuously during thermal cycling. This paper provides the experimental test results of advanced CCGA packages tested in extreme temperature thermal environments. Standard optical inspection and x-ray non-destructive inspection tools were used to assess the reliability of high density CCGA packages for deep space extreme temperature missions.
Development and Testing of an Inflatable, Rigidizable Space Structure Experiment
2006-03-01
successful, including physical dimension, weight , and cost. Inflatable structures have the potential to achieve greater efficiency in all of these...potential for low cost, high mechanical packaging efficiency, deployment reliability and low weight (13). The term inflatable structure indicates that a...back-up inflation gas a necessity for long term success. This addition can be very costly in terms of volume, weight , and expense due to added or
Status of the advanced Stirling conversion system project for 25 kW dish Stirling applications
NASA Technical Reports Server (NTRS)
Shaltens, Richard K.; Schreiber, Jeffrey G.
1991-01-01
Technology development for Stirling convertors directed toward a dynamic power source for space applications is discussed. Space power requirements include high reliability with very long life, low vibration, and high system efficiency. The free-piston Stirling engine has the potential for future high power space conversion systems, either nuclear or solar powered. Although these applications appear to be quite different, their requirements complement each other. The advanced Stirling conversion system (ASCS) project at NASA Lewis Research Center is described. Each system design features a solar receiver/liquid metal heat transport system and a free-piston Stirling convertor with a means to provide nominally 25 kW of electric power to utility grid while meeting the US Department of Energy (DOE) performance and long term cost goals. The design is compared with other ASCS designs.
Backcasting long-term climate data: evaluation of hypothesis
NASA Astrophysics Data System (ADS)
Saghafian, Bahram; Aghbalaghi, Sara Ghasemi; Nasseri, Mohsen
2018-05-01
Most often than not, incomplete datasets or short-term recorded data in vast regions impedes reliable climate and water studies. Various methods, such as simple correlation with stations having long-term time series, are practiced to infill or extend the period of observation at stations with missing or short-term data. In the current paper and for the first time, the hypothesis on the feasibility of extending the downscaling concept to backcast local observation records using large-scale atmospheric predictors is examined. Backcasting is coined here to contrast forecasting/projection; the former is implied to reconstruct in the past, while the latter represents projection in the future. To assess our hypotheses, daily and monthly statistical downscaling models were employed to reconstruct past precipitation data and lengthen the data period. Urmia and Tabriz synoptic stations, located in northwestern Iran, constituted two case study stations. SDSM and data-mining downscaling model (DMDM) daily as well as the group method of data handling (GMDH) and model tree (Mp5) monthly downscaling models were trained with National Center for Environmental Prediction (NCEP) data. After training, reconstructed precipitation data of the past was validated against observed data. Then, the data was fully extended to the 1948 to 2009 period corresponding to available NCEP data period. The results showed that DMDM performed superior in generation of monthly average precipitation compared with the SDSM, Mp5, and GMDH models, although none of the models could preserve the monthly variance. This overall confirms practical value of the proposed approach in extension of the past historic data, particularly for long-term climatological and water budget studies.
Highly Ordered TiO2 Microcones with High Rate Performance for Enhanced Lithium-Ion Storage.
Rhee, Oonhee; Lee, Gibaek; Choi, Jinsub
2016-06-15
The perpendicularly oriented anatase TiO2 microcones for Li-ion battery application were synthesized via anodization of a Ti foil in aqueous HF + H3PO4 solution. The TiO2 microcones exhibited a high active surface area with a hollow core depending on applied voltage and reaction time, confirmed by SEM, XRD and TEM with EDS mapping. Li insertion/desertion into TiO2 microcones was evaluated for the first time in half-cell configuration in terms of various current density and long-term cyclability. The electrochemical experiments demonstrated that the as-prepared TiO2 microcones as anode material exhibited 3 times higher capacity as compared with TiO2 nanotubular structures, excellent rate performance (0.054 mAhcm(-2) even at 50 C) and reliable capacity retention during 500 cycles, which was attributed to facile diffusion of Li-ions induced in hollow anatase TiO2 microcones structure with multilayered nanofragment.
Characterization and Reliability of Vertical N-Type Gallium Nitride Schottky Contacts
2016-09-01
barrier diode SEM scanning electron microscopy SiC silicon carbide SMU source measure unit xvi THIS PAGE INTENTIONALLY LEFT BLANK xvii...arguably the Schottky barrier diode (SBD). The SBD is a fundamental component in the majority of power electronic devices; specifically, those used in...Ishizuka, and Ueno demonstrated the long-term reliability of vertical metal-GaN Schottky barrier diodes through their analysis of the degradation
Chowdhury, Enayet K; Jennings, Garry L R; Dewar, Elizabeth; Wing, Lindon M H; Reid, Christopher M
2016-07-01
Hypertension leads to cardiac structural and functional changes, commonly assessed by echocardiography. In this study, we assessed the predictive performance of different echocardiographic parameters including left ventricular hypertrophy (LVH) on future cardiovascular outcomes in elderly hypertensive patients without heart failure. Data from LVH substudy of the Second Australian National Blood Pressure trial were used. Echocardiograms were performed at entry into the study. Cardiovascular outcomes were identified over short term (median 4.2 years) and long term (median 10.9 years). LVH was defined using threshold values of LV mass (LVM) indexed to either body surface area (BSA) or height(2.7): >115/95g/m(2) (LVH-BSA(115/95)) or ≥49/45g/m(2.7) (LVH-ht(49/45)) in males/females, respectively, and ≥125g/m(2) (LVH-BSA(125)) or ≥51g/m(2.7) (LVH-ht(51)) for both sexes. In the 666 participants aged ≥65 years in this analysis, LVH prevalence at baseline was 33%-70% depending on definition; and after adjusting for potential risk factors, only LVH-BSA(115/95) predicted both short- and long-term cardiovascular outcomes. Participants having LVH-BSA(115/95) (69%) at baseline had twice the risk of having any first cardiovascular event over the short term (hazard ratio, 95% confidence interval: 2.00, 1.12-3.57, P = 0.02) and any fatal cardiovascular events (2.11, 1.21-3.68, P = 0.01) over the longer term. Among other echocardiographic parameters, LVM and LVM indexed to either BSA or height(2.7) predicted cardiovascular events over both short and longer term. In elderly treated hypertensive patients without heart failure, determining LVH by echocardiography is highly dependent on the methodology adopted. LVH-BSA(115/95) is a reliable predictor of future cardiovascular outcomes in the elderly. © American Journal of Hypertension, Ltd 2016. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Regenerable Photovoltaic Devices with a Hydrogel-Embedded Microvascular Network
Koo, Hyung-Jun; Velev, Orlin D.
2013-01-01
Light-driven degradation of photoactive molecules could be one of the major obstacles to stable long term operation of organic dye-based solar light harvesting devices. One solution to this problem may be mimicking the regeneration functionality of a plant leaf. We report an organic dye photovoltaic system that has been endowed with such microfluidic regeneration functionality. A hydrogel medium with embedded channels allows rapid and uniform supply of photoactive reagents by a convection-diffusion mechanism. A washing-activation cycle enables reliable replacement of the organic component in a dye-sensitized photovoltaic system. Repetitive restoration of photovoltaic performance after intensive device degradation is demonstrated. PMID:23912814
Text mining by Tsallis entropy
NASA Astrophysics Data System (ADS)
Jamaati, Maryam; Mehri, Ali
2018-01-01
Long-range correlations between the elements of natural languages enable them to convey very complex information. Complex structure of human language, as a manifestation of natural languages, motivates us to apply nonextensive statistical mechanics in text mining. Tsallis entropy appropriately ranks the terms' relevance to document subject, taking advantage of their spatial correlation length. We apply this statistical concept as a new powerful word ranking metric in order to extract keywords of a single document. We carry out an experimental evaluation, which shows capability of the presented method in keyword extraction. We find that, Tsallis entropy has reliable word ranking performance, at the same level of the best previous ranking methods.
A Simple Device for Morphofunctional Evaluation During Aortic Valve-Sparing Surgery.
Leone, Alessandro; Bruno, Piergiorgio; Cammertoni, Federico; Massetti, Massimo
2015-07-01
Valve-sparing operations for the treatment of aortic root disease with a structurally normal aortic valve are increasingly performed as they avoid prosthesis-related complications. Short- and long-term results are critically dependent on perfect intraoperative restoration of valve anatomy and function. Residual aortic regurgitation is the main cause of early failure, and it is the most common motive for reoperation. However, intraoperative morphofunctional valve assessment requires expertise, and only transesophageal echocardiography can provide reliable information. We describe a simple, economic, reproducible hydrostatic test to intraoperatively evaluate valve competency under direct visualization. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Direct patterning of organic conductors on knitted textiles for long-term electrocardiography
NASA Astrophysics Data System (ADS)
Takamatsu, Seiichi; Lonjaret, Thomas; Crisp, Dakota; Badier, Jean-Michel; Malliaras, George G.; Ismailova, Esma
2015-10-01
Wearable sensors are receiving a great deal of attention as they offer the potential to become a key technological tool for healthcare. In order for this potential to come to fruition, new electroactive materials endowing high performance need to be integrated with textiles. Here we present a simple and reliable technique that allows the patterning of conducting polymers on textiles. Electrodes fabricated using this technique showed a low impedance contact with human skin, were able to record high quality electrocardiograms at rest, and determine heart rate even when the wearer was in motion. This work paves the way towards imperceptible electrophysiology sensors for human health monitoring.
Ma, Ning; Cheng, Huaibing; Lu, Minjie; Liu, Qiong; Chen, Xiuyu; Yin, Gang; Zhu, Hao; Zhang, Lianfeng; Meng, Xianmin; Tang, Yue; Zhao, Shihua
2015-03-12
MRI for in vivo stem cell tracking remains controversial. Here we tested the hypothesis that MRI can track the long-term fate of the superparamagnetic iron oxide (SPIO) nanoparticles labelled mesenchymal stem cells (MSCs) following intramyocardially injection in AMI rats. MSCs (1 × 10(6)) from male rats doubly labeled with SPIO and DAPI were injected 2 weeks after myocardial infarction. The control group received cell-free media injection. In vivo serial MRI was performed at 24 hours before cell delivery (baseline), 3 days, 1, 2, and 4 weeks after cell delivery, respectively. Serial follow-up MRI demonstrated large persistent intramyocardial signal-voids representing SPIO during the follow-up of 4 weeks, and MSCs did not moderate the left ventricular dysfunction. The TUNEL analysis confirmed that MSCs engrafted underwent apoptosis. The histopathological studies revealed that the site of cell injection was infiltrated by inflammatory cells progressively and the iron-positive cells were macrophages identified by CD68 staining, but very few or no DAPI-positive stem cells at 4 weeks after cells transplantation. The presence of engrafted cells was confirmed by real-time PCR, which showed that the amount of Y-chromosome-specific SRY gene was consistent with the results. MRI may not reliably track the long-term fate of SPIO-labeled MSCs engraftment in heart.
Does long-term object priming depend on the explicit detection of object identity at encoding?
Gomes, Carlos A.; Mayes, Andrew
2015-01-01
It is currently unclear whether objects have to be explicitly identified at encoding for reliable behavioral long-term object priming to occur. We conducted two experiments that investigated long-term object and non-object priming using a selective-attention encoding manipulation that reduces explicit object identification. In Experiment 1, participants either counted dots flashed within an object picture (shallow encoding) or engaged in an animacy task (deep encoding) at study, whereas, at test, they performed an object-decision task. Priming, as measured by reaction times (RTs), was observed for both types of encoding, and was of equivalent magnitude. In Experiment 2, non-object priming (faster RTs for studied relative to unstudied non-objects) was also obtained under the same selective-attention encoding manipulation as in Experiment 1, and the magnitude of the priming effect was equivalent between experiments. In contrast, we observed a linear decrement in recognition memory accuracy across conditions (deep encoding of Experiment 1 > shallow encoding Experiment 1 > shallow encoding of Experiment 2), suggesting that priming was not contaminated by explicit memory strategies. We argue that our results are more consistent with the identification/production framework than the perceptual/conceptual distinction, and we conclude that priming of pictures largely ignored at encoding can be subserved by the automatic retrieval of two types of instances: one at the motor level and another at an object-decision level. PMID:25852594
Psychometric properties and norms of the German ABC-Community and PAS-ADD Checklist.
Zeilinger, Elisabeth L; Weber, Germain; Haveman, Meindert J
2011-01-01
The aim of the present study was to standardize and generate psychometric evidence of the German language versions of two well-established English language mental health instruments: the Aberrant Behavior Checklist-Community (ABC-C) and the Psychiatric Assessment Schedule for Adults with Developmental Disabilities (PAS-ADD) Checklist. New methods in this field were introduced: a simulation method for testing the factor structure and an exploration of long-term stability over two years. The checklists were both administered to a representative sample of 270 individuals with intellectual disability (ID) and, two years later in a second data collection, to 128 participants of the original sample. Principal component analysis and parallel analysis were performed. Reliability measures, long-term stability, subscale intercorrelations, as well as standardized norms were generated. Prevalence of mental health problems was examined. Psychometric properties were mostly excellent, with long-term stability showing moderate to strong effects. The original factor structure of the ABC-C was replicated. PAS-ADD Checklist produced a similar, but still different structure compared with findings from the English language area. The overall prevalence rate of mental health problems in the sample was about 20%. Considering the good results on the measured psychometric properties, the two checklists are recommended for the early detection of mental health problems in persons with ID. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kitano, Tomoya; Iwasaki, Kiyotaka
The EVAHEART Left Ventricular Assist System (LVAS) was designed for the long-term support of a patient with severe heart failure. It has an original water lubrication system for seal and bearing and wear on these parts was considered one of its critical failure modes. A durability test focusing on wear was designed herein. We developed a mock loop, which generates a physiologic pulsatile flow and is sufficiently durable for a long-term test. The pulsatile load and the low fluid viscosity enable the creation of a severe condition for the mechanical seal. A total of 18 EVAHEART blood pumps completed 2 years of operation under the pulsatile condition without any failure. It indicated the EVAHEART blood pump had a greater than 90% reliability with a 88% confidence level. The test was continued with six blood pumps and achieved an average of 8.6 years, which was longer than the longest clinical use in Japan. The test result showed that no catastrophic, critical, marginal, or minor failures of the blood pump or their symptoms were observed. The seal performance was maintained after the test. Moreover, the surface roughness did not change, which showed any burn or abnormal wear occurred. The original water lubrication system equipped in EVAHEART LVAS prevent severe wear on the seal and the bearing, and it can be used in the bridge to transplant and destination therapy.
Challenges in the 1990's for astronaut training simulators
NASA Technical Reports Server (NTRS)
Brown, Patrick M.; Hajare, Ankur R.; Stark, George E.
1990-01-01
New challenges for the simulation community at the Johnson Space Center both in near and long terms are considered. In the near term, the challenges of supporting an increasing flight rate, maintaining operations while replacing obsolete subsystems, and incorporating forthcoming changes to the Space Shuttle are discussed, and focus is placed on a change of forward flight-deck instruments from electro-mechanical devices to electronic displays. Training astronauts for complex concurrent missions involving multiple spacecraft and geographically dispersed ground facilities is considered to be foremost of the long-term challenges, in addition to the tasks of improving the simulator reliability and the operational efficiency of the facilities.
Li, Chunyan; Wu, Pei-Ming; Wu, Zhizhen; Ahn, Chong H; LeDoux, David; Shutter, Lori A; Hartings, Jed A; Narayan, Raj K
2012-02-01
The injured brain is vulnerable to increases in temperature after severe head injury. Therefore, accurate and reliable measurement of brain temperature is important to optimize patient outcome. In this work, we have fabricated, optimized and characterized temperature sensors for use with a micromachined smart catheter for multimodal intracranial monitoring. Developed temperature sensors have resistance of 100.79 ± 1.19Ω and sensitivity of 67.95 mV/°C in the operating range from15-50°C, and time constant of 180 ms. Under the optimized excitation current of 500 μA, adequate signal-to-noise ratio was achieved without causing self-heating, and changes in immersion depth did not introduce clinically significant errors of measurements (<0.01°C). We evaluated the accuracy and long-term drift (5 days) of twenty temperature sensors in comparison to two types of commercial temperature probes (USB Reference Thermometer, NIST-traceable bulk probe with 0.05°C accuracy; and IT-21, type T type clinical microprobe with guaranteed 0.1°C accuracy) under controlled laboratory conditions. These in vitro experimental data showed that the temperature measurement performance of our sensors was accurate and reliable over the course of 5 days. The smart catheter temperature sensors provided accuracy and long-term stability comparable to those of commercial tissue-implantable microprobes, and therefore provide a means for temperature measurement in a microfabricated, multimodal cerebral monitoring device.
Bridge deterioration models to support Indiana's bridge management system.
DOT National Transportation Integrated Search
2016-02-01
An effective bridge management system that is equipped with reliable deterioration models enables agency engineers to carry out : monitoring and long-term programming of bridge repair actions. At the project level, deterioration models help the agenc...
Test-retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects.
Cutajar, Marica; Clayden, Jonathan D; Clark, Christopher A; Gordon, Isky
2011-12-01
This study assessed test-retest reliability and repeatability of diffusion tensor imaging (DTI) in the kidneys. Seven healthy volunteers (age range, 19-31 years), were imaged three consecutive times on the same day (short-term reliability) and the same imaging protocol was repeated after a month (long-term reliability). Diffusion-weighted magnetic resonance imaging scans in the coronal-oblique projection of the kidney were acquired on a 1.5 T scanner using a multi-section echo-planar sequence; six contiguous slices each 5 mm thick, diffusion sensitisation along 20 non-collinear directions, TR=730 ms, TE=73 ms and 2 b-values (0 and 400 s mm(-2)). Volunteers were asked to hold their breath throughout each data acquisition (approx. 20 s). The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were obtained from maps generated using dedicated software MIStar (Apollo Medical Imaging, Melbourne, Australia). Statistical analyses of both short- and long-term repeats were carried out from which the within-subject coefficient of variation (wsCV) was calculated. The wsCV obtained for both the ADC and FA values were less than 10% in all the analyses carried out. In addition, paired (repeated measures) t-test was used to measure the variation between the diffusion parameters collected from the two scanning sessions a month apart. It showed no significant difference and the wsCV obtained after comparing the first and second scans were found to be smaller than 15% for both ADC and FA. Renal DTI produces reliable and repeatable results which make longitudinal investigation of patients viable. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brauner, Edwin Jr.; Carlson, Daniel C.
The Geysers steamfields in northern Sonoma County have produced reliable ''green'' power for many years. An impediment to long-term continued production has been the ability to provide a reliable source of injection water to replace water extracted and lost in the form of steam. The steamfield operators have historcially used cooling towers to recycle a small portion of the steam and have collected water during the winter months using stream extraction. These two sources, however, could not by themselves sustain the steamfield in the long term. The Lake County Reclaimed Water Project (SEGEP) was inititated in 1997 and provides anothermore » source of steamfield replenishment water. The Santa Rosa Geysers Recharge Project provides another significant step in replenishing the steamfield. In addition, the Santa Rosa Geysers Recharge Project has been built with capacity to potentially meet virtually all injection water requirements, when combined with these other sources. Figure 2.1 graphically depicts the combination of injection sources.« less
Implementing a Reliability Centered Maintenance Program at NASA's Kennedy Space Center
NASA Technical Reports Server (NTRS)
Tuttle, Raymond E.; Pete, Robert R.
1998-01-01
Maintenance practices have long focused on time based "preventive maintenance" techniques. Components were changed out and parts replaced based on how long they had been in place instead of what condition they were in. A reliability centered maintenance (RCM) program seeks to offer equal or greater reliability at decreased cost by insuring only applicable, effective maintenance is performed and by in large part replacing time based maintenance with condition based maintenance. A significant portion of this program involved introducing non-intrusive technologies, such as vibration analysis, oil analysis and I/R cameras, to an existing labor force and management team.
Hippocampal CA1 Kindling but Not Long-Term Potentiation Disrupts Spatial Memory Performance
ERIC Educational Resources Information Center
Leung, L. Stan; Shen, Bixia
2006-01-01
Long-term synaptic enhancement in the hippocampus has been suggested to cause deficits in spatial performance. Synaptic enhancement has been reported after hippocampal kindling that induced repeated electrographic seizures or afterdischarges (ADs) and after long-term potentiation (LTP) defined as synaptic enhancement without ADs. We studied…
DOT National Transportation Integrated Search
2009-06-01
This report describes the investigation of the long term structural performance of a : hybrid FRP-concrete (HFRPC) bridge deck on steel girders. The study aimed at : assessing three long term aspects pertaining to the HFRPC bridge deck: (1) creep : c...
Long-Term Orientation and Educational Performance. Working Paper 174
ERIC Educational Resources Information Center
Figlio, David; Giuliano, Paola; Özek, Umut; Sapienza, Paola
2017-01-01
We use remarkable population-level administrative education and birth records from Florida to study the role of Long-Term Orientation on the educational attainment of immigrant students living in the US. Controlling for the quality of schools and individual characteristics, students from countries with long-term oriented attitudes perform better…
Effects of Radiation and Long-Term Thermal Cycling on EPC 1001 Gallium Nitride Transistors
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Scheick, Leif; Lauenstein, Jean-Marie; Casey, Megan; Hammoud, Ahmad
2012-01-01
Electronics designed for use in NASA space missions are required to work efficiently and reliably under harsh environment conditions. These include radiation, extreme temperatures, and thermal cycling, to name a few. Data obtained on long-term thermal cycling of new un-irradiated and irradiated samples of EPC1001 gallium nitride enhancement-mode transistors are presented. This work was done by a collaborative effort including GRC, GSFC, and support the NASA www.nasa.gov 1 JPL in of Electronic Parts and Packaging (NEPP) Program
Kleinhappel, T K; Al-Zoubi, A; Al-Diri, B; Burman, O; Dickinson, P; John, L; Wilkinson, A; Pike, T W
2014-04-01
This paper describes and evaluates a flexible, non-invasive tagging system for the automated identification and long-term monitoring of individual three-spined sticklebacks Gasterosteus aculeatus. The system is based on barcoded tags, which can be reliably and robustly detected and decoded to provide information on an individual's identity and location. Because large numbers of fish can be individually tagged, it can be used to monitor individual- and group-level dynamics within fish shoals. © 2014 The Fisheries Society of the British Isles.
Agar-Silica-Gel Heating Phantom May Be Suitable for Long-Term Quality Assurance of MRgHIFU
NASA Astrophysics Data System (ADS)
Partanen, Ari
2009-04-01
In MRgHIFU, the purpose of frequent quality assurance is to detect changes in system performance to prevent adverse effects during treatments. Due to high ultrasound intensities in MRgHIFU, it is essential to assure that the procedure is safe and efficacious and that image-based guidance of the treatment is reliable. We aimed to develop a guideline for MRgHIFU QA by acquiring MR temperature maps during ultrasonic heating of an agar-silica-gel phantom over a four month-period using three separate MRgHIFU uterine leiomyoma treatment systems. From this data, the stability of the maximum temperature elevation, the targeting accuracy, and the dimensions of the heated volume were analyzed. Additionally, we studied the sensitivity of these parameters to reveal hypothetical decrease in HIFU performance. After calibration, the mean targeting offsets of the heated volume were observed to be less than 2 mm in the three orthogonal directions. The measured maximum temperature elevation and the length and the width of the heated volume remained consistent throughout the four-month period. Furthermore, it was found that the parameters under investigation were sensitive to reveal the decreased HIFU performance. We conclude that an agar-silica -based phantom is suitable for targeting accuracy and heating properties QA of MRgHIFU system even in long-term use. Moreover, this simple QA method may be used to reveal small changes in HIFU performance assuring consistent functionality and safety of the MRgHIFU system.
Ramírez-Vélez, Robinson; Rodrigues-Bezerra, Diogo; Correa-Bautista, Jorge Enrique; Izquierdo, Mikel; Lobelo, Felipe
2015-01-01
Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study’s aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion “Fuprecol study”. Participants were 229 Colombian youth (boys n = 124 and girls n = 105) aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1) morphological component: height, weight, body mass index (BMI), waist circumference, triceps skinfold, subscapular skinfold, and body fat (%) via impedance; 2) musculoskeletal component: handgrip and standing long jump test; 3) motor component: speed/agility test (4x10 m shuttle run); 4) flexibility component (hamstring and lumbar extensibility, sit-and-reach test); 5) cardiorespiratory component: 20-meter shuttle-run test (SRT) to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs) and inter-rater (reliability) were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland–Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias) and random error (95% limits of agreement). When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the “Fuprecol study” health-related physical fitness battery, administered by physical education teachers, was reliable for measuring health-related components of fitness in children and adolescents aged 9–17.9 years old in a school setting in Colombia. PMID:26474474
Ramírez-Vélez, Robinson; Rodrigues-Bezerra, Diogo; Correa-Bautista, Jorge Enrique; Izquierdo, Mikel; Lobelo, Felipe
2015-01-01
Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study's aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion "Fuprecol study". Participants were 229 Colombian youth (boys n = 124 and girls n = 105) aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1) morphological component: height, weight, body mass index (BMI), waist circumference, triceps skinfold, subscapular skinfold, and body fat (%) via impedance; 2) musculoskeletal component: handgrip and standing long jump test; 3) motor component: speed/agility test (4x10 m shuttle run); 4) flexibility component (hamstring and lumbar extensibility, sit-and-reach test); 5) cardiorespiratory component: 20-meter shuttle-run test (SRT) to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs) and inter-rater (reliability) were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland-Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias) and random error (95% limits of agreement). When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the "Fuprecol study" health-related physical fitness battery, administered by physical education teachers, was reliable for measuring health-related components of fitness in children and adolescents aged 9-17.9 years old in a school setting in Colombia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puskar, Joseph David; Quintana, Michael A.; Sorensen, Neil Robert
A program is underway at Sandia National Laboratories to predict long-term reliability of photovoltaic (PV) systems. The vehicle for the reliability predictions is a Reliability Block Diagram (RBD), which models system behavior. Because this model is based mainly on field failure and repair times, it can be used to predict current reliability, but it cannot currently be used to accurately predict lifetime. In order to be truly predictive, physics-informed degradation processes and failure mechanisms need to be included in the model. This paper describes accelerated life testing of metal foil tapes used in thin-film PV modules, and how tape jointmore » degradation, a possible failure mode, can be incorporated into the model.« less
NASA Astrophysics Data System (ADS)
El Hattab, M. H.; Vernon, D.; Mijic, A.
2017-12-01
Low impact development practices (LID) are deemed to have a synergetic effect in mitigating urban storm water flooding. Designing and implementing effective LID practices require reliable real-life data about their performance in different applications; however, there are limited studies providing such data. In this study an innovative micro-monitoring system to assess the performance of porous pavement and rain gardens as retrofitting technologies was developed. Three pilot streets in London, UK were selected as part of Thames Water Utilities Limited's Counters Creek scheme. The system includes a V-notch weir installed at the outlet of each LID device to provide an accurate and reliable quantification over a wide range of discharges. In addition to, a low flow sensor installed downstream of the V-notch to cross-check the readings. Having a flow survey time-series of the pre-retrofitting conditions from the study streets, extensive laboratory calibrations under different flow conditions depicting the exact site conditions were performed prior to installing the devices in the field. The micro-monitoring system is well suited for high-resolution temporal monitoring and enables accurate long-term evaluation of LID components' performance. Initial results from the field validated the robustness of the system in fulfilling its requirements.
Joswig, Holger; Neff, Armin; Ruppert, Christina; Hildebrandt, Gerhard; Stienen, Martin Nikolaus
2018-05-01
The predictive value of short-term arm pain relief after 'indirect' cervical epidural steroid injection (ESI) for the 1-month treatment response has been previously demonstrated. It remained to be answered whether the long-term response could be estimated by the early post-interventional pain course as well. Prospective observational study, following a cohort of n = 45 patients for a period of 24 months after 'indirect' ESI for radiculopathy secondary to a single-level cervical disk herniation (CDH). Arm and neck pain on the visual analog scale (VAS), health-related quality of life with the Short Form-12 (SF-12), and functional outcome with the Neck Pain and Disability (NPAD) Scale were assessed. Any additional invasive treatment after a single injection (second injection or surgery) defined treatment outcome as 'non-response'. At 24 months, n = 30 (66.7%) patients were responders and n = 15 (33.3%) were non-responders. Non-responders exited the follow-up at 1 month (n = 10), at 3 months (n = 4), and at 6 months (n = 1). No patients were injected again or operated on between the 6- and 24-month follow-up. Patients with favorable treatment response at 24 months had significantly lower VAS arm pain (p < 0.05) than non-responders at days 6, 8-11, and at the 3-month follow-up. The previously defined cut-off of > 50% short term pain reduction was not a reliable predictor of the 24-month responder status. SF-12 and NPAD scores were better among treatment responders in the long term. Patients who require a second injection or surgery after 'indirect' cervical ESI for a symptomatic CDH do so within the first 6 months. Short-term pain relief cannot reliably predict the long-term outcome.
ERIC Educational Resources Information Center
Pholphirul, Piriya
2017-01-01
Several research papers have assessed the long-term benefits of pre-primary education in terms of academic performance and labor market outcomes. This study analyzes data obtained from the Programme for International Student Assessment (PISA) to estimate the effects of preschool enrollment of Thai students on producing long-term benefits in their…
Rose, Nathan S; Buchsbaum, Bradley R; Craik, Fergus I M
2014-07-01
Many working memory (WM) models propose that the focus of attention (or primary memory) has a capacity limit of one to four items, and therefore, that performance on WM tasks involves retrieving some items from long-term (or secondary) memory (LTM). In the present study, we present evidence suggesting that recall of even one item on a WM task can involve retrieving it from LTM. The WM task required participants to make a deep (living/nonliving) or shallow ("e"/no "e") level-of-processing (LOP) judgment on one word and to recall the word after a 10-s delay on each trial. During the delay, participants either rehearsed the word or performed an easy or a hard math task. When the to-be-remembered item could be rehearsed, recall was fast and accurate. When it was followed by a math task, recall was slower, error-prone, and benefited from a deeper LOP at encoding, especially for the hard math condition. The authors suggest that a covert-retrieval mechanism may have refreshed the item during easy math, and that the hard math condition shows that even a single item cannot be reliably held in WM during a sufficiently distracting task--therefore, recalling the item involved retrieving it from LTM. Additionally, performance on a final free recall (LTM) test was better for items recalled following math than following rehearsal, suggesting that initial recall following math involved elaborative retrieval from LTM, whereas rehearsal did not. The authors suggest that the extent to which performance on WM tasks involves retrieval from LTM depends on the amounts of disruption to both rehearsal and covert-retrieval/refreshing maintenance mechanisms.
Safety and Efficacy of Rivastigmine in Adolescents with Down Syndrome: Long-Term Follow-Up
Spiridigliozzi, Gail A.; Crissman, Blythe G.; McKillop, Jane Anne; Yamamoto, Haru; Kishnani, Priya S.
2010-01-01
Abstract Following the completion of a 20-week, open-label study of the safety and efficacy of liquid rivastigmine for adolescents with Down syndrome, 5 of the 10 adolescents in the clinical trial continued long-term rivastigmine therapy and 5 did not. After an average period of 38 months, all 10 subjects returned for a follow-up assessment to determine the safety and efficacy of long-term rivastigmine use. Rivastigmine was well tolerated and overall health appeared to be unaffected by long-term rivastigmine use. Performance change on cognitive and language measures administered at the termination of the open-label clinical trial was compared between the two groups. No between-group difference in median performance change across the long-term period was found, suggesting that the long-term use of rivastigmine does not improve cognitive and language performance. However, two subjects demonstrated remarkable improvement in adaptive function over the long-term period. Both subjects had received long-term rivastigmine therapy. The discussion addresses the challenge of assessing cognitive change in clinical trials using adolescents with Down syndrome as subjects and the use of group versus individual data to evaluate the relevance of medication effects. PMID:21186971
Systems Engineering Provides Successful High Temperature Steam Electrolysis Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charles V. Park; Emmanuel Ohene Opare, Jr.
2011-06-01
This paper describes two Systems Engineering Studies completed at the Idaho National Laboratory (INL) to support development of the High Temperature Stream Electrolysis (HTSE) process. HTSE produces hydrogen from water using nuclear power and was selected by the Department of Energy (DOE) for integration with the Next Generation Nuclear Plant (NGNP). The first study was a reliability, availability and maintainability (RAM) analysis to identify critical areas for technology development based on available information regarding expected component performance. An HTSE process baseline flowsheet at commercial scale was used as a basis. The NGNP project also established a process and capability tomore » perform future RAM analyses. The analysis identified which components had the greatest impact on HTSE process availability and indicated that the HTSE process could achieve over 90% availability. The second study developed a series of life-cycle cost estimates for the various scale-ups required to demonstrate the HTSE process. Both studies were useful in identifying near- and long-term efforts necessary for successful HTSE process deployment. The size of demonstrations to support scale-up was refined, which is essential to estimate near- and long-term cost and schedule. The life-cycle funding profile, with high-level allocations, was identified as the program transitions from experiment scale R&D to engineering scale demonstration.« less
Shen, Chaobo; Hai, Zhou; Zhao, Cong; Zhang, Jiawei; Evans, John L.; Bozack, Michael J.; Suhling, Jeffrey C.
2017-01-01
This study illustrates test results and comparative literature data on the influence of isothermal aging and thermal cycling associated with Sn-1.0Ag-0.5Cu (SAC105) and Sn-3.0Ag-0.5Cu (SAC305) ball grid array (BGA) solder joints finished with ENIG and ENEPIG on the board side and ENIG on the package side compared with ImAg plating on both sides. The resulting degradation data suggests that the main concern for 0.4 mm pitch 10 mm package size BGA is package side surface finish, not board side. That is, ENIG performs better than immersion Ag for applications involving long-term isothermal aging. SAC305, with a higher relative fraction of Ag3Sn IMC within the solder, performs better than SAC105. SEM and polarized light microscope analysis show cracks propagated from the corners to the center or even to solder bulk, which eventually causes fatigue failure. Three factors are discussed: IMC, grain structure, and Ag3Sn particle. The continuous growth of Cu-Sn intermetallic compounds (IMC) and grains increase the risk of failure, while Ag3Sn particles seem helpful in blocking the crack propagation. PMID:28772811
Mohebifar, Rafat; Hasani, Hana; Barikani, Ameneh; Rafiei, Sima
2016-08-01
Providing high service quality is one of the main functions of health systems. Measuring service quality is the basic prerequisite for improving quality. The aim of this study was to evaluate the quality of service in teaching hospitals using importance-performance analysis matrix. A descriptive-analytic study was conducted through a cross-sectional method in six academic hospitals of Qazvin, Iran, in 2012. A total of 360 patients contributed to the study. The sampling technique was stratified random sampling. Required data were collected based on a standard questionnaire (SERVQUAL). Data analysis was done through SPSS version 18 statistical software and importance-performance analysis matrix. The results showed a significant gap between importance and performance in all five dimensions of service quality (p < 0.05). In reviewing the gap, "reliability" (2.36) and "assurance" (2.24) dimensions had the highest quality gap and "responsiveness" had the lowest gap (1.97). Also, according to findings, reliability and assurance were in Quadrant (I), empathy was in Quadrant (II), and tangibles and responsiveness were in Quadrant (IV) of the importance-performance matrix. The negative gap in all dimensions of quality shows that quality improvement is necessary in all dimensions. Using quality and diagnosis measurement instruments such as importance-performance analysis will help hospital managers with planning of service quality improvement and achieving long-term goals.
Xu, Ming-Xing; Liu, Chang; He, Yong-Ming; Yang, Xiang-Jun; Zhao, Xin
2017-05-01
Lipoprotein (a) [Lp (a)] is a well-established risk factor for coronary artery disease (CAD). However, up till now, treatment of patients with higher Lp (a) levels is challenging. This current study aimed to investigate the therapeutic effects of short-, medium and long-term statin use on the Lp (a) reduction and its modifying factors. The therapeutic duration was categorized into short-term (median, 39 days), medium term (median, 219 days) and long-term (median, 677 days). The lipid profiles before therapy served as baselines. Patients at short-, medium or long-term exactly matched with those at baseline. Every patient's lipid profiles during the follow-ups were compared to his own ones at baselines. The current study demonstrated that long-term statin therapy significantly decreased the Lp (a) levels in CAD patients while short-term or medium term statin therapy didn't. When grouped by statin use, only long-term simvastatin use significantly decreased the Lp (a) levels while long-term atorvastatin use insignificantly decreased the Lp (a) levels. Primary hypertension (PH), DM, low density lipoprotein cholesterol (LDL-C) and high density lipoprotein cholesterol (HDL-C) could modify the therapeutic effects of statin use on the Lp (a) levels in CAD patients. The long-term statin therapy could be efficacious in reducing the Lp (a) levels in CAD patients, which has been modified by some traditional risk factors. In the era of commercial unavailability of more reliable Lp (a) lowering drugs, our findings will bolster confidence in fighting higher Lp (a) abnormalities both for patients and for doctors.
NASA Astrophysics Data System (ADS)
Auciello, Orlando; Shi, Bing
Extensive research has been devoted to the development of neuron prostheses and hybrid bionic systems to establish links between the nervous system and electronic or robotic prostheses with the main focus of restoring motor and sensory functions in blind patients. Artificial retinas, one type of neural prostheses we are currently working on, aim to restore some vision in blind patients caused by retinitis picmentosa or macular degeneration, and in the future to restore vision at the level of face recognition, if not more. Currently there is no hermetic microchip-size coating that provides a reliable, long-term (years) performance as encapsulating coating for the artificial retina Si microchip to be implanted inside the eye. This chapter focuses on the critical topics relevant to the development of a robust, long-term artificial retina device, namely the science and technology of hermetic bio-inert encapsulating coatings to protect a Si microchip implanted in the human eye from being attacked by chemicals existing in the eye's saline environment. The work discussed in this chapter is related to the development of a novel ultrananocrystalline diamond (UNCD) hermetic coating, which exhibited no degradation in rabbit eyes. The material synthesis, characterization, and electrochemical properties of these hermetic coatings are reviewed for application as encapsulating coating for the artificial retinal microchips implantable inside the human eye. Our work has shown that UNCD coatings may provide a reliable hermetic bio-inert coating technology for encapsulation of Si microchips implantable in the eye specifically and in the human body in general. Electrochemical tests of the UNCD films grown under CH4/Ar/H2 (1%) plasma exhibit the lowest leakage currents (˜7 × 10-7 A/cm2) in a saline solution simulating the eye environment. This leakage is incompatible with the functionality of the first-generation artificial retinal microchip. However, the growth of UNCD on top of the Si microchip passivated by a silicon nitride layer or the oxide layers is also under investigation in our group as introduced in this chapter. The electrochemically induced leakage will be reduced by at least one to three orders of magnitude to the range of 10-10 A/cm2, which is compatible with reliable, long-term implants.
System Analysis and Performance Benefits of an Optimized Rotorcraft Propulsion System
NASA Technical Reports Server (NTRS)
Bruckner, Robert J.
2007-01-01
The propulsion system of rotorcraft vehicles is the most critical system to the vehicle in terms of safety and performance. The propulsion system must provide both vertical lift and forward flight propulsion during the entire mission. Whereas propulsion is a critical element for all flight vehicles, it is particularly critical for rotorcraft due to their limited safe, un-powered landing capability. This unparalleled reliability requirement has led rotorcraft power plants down a certain evolutionary path in which the system looks and performs quite similarly to those of the 1960 s. By and large the advancements in rotorcraft propulsion have come in terms of safety and reliability and not in terms of performance. The concept of the optimized propulsion system is a means by which both reliability and performance can be improved for rotorcraft vehicles. The optimized rotorcraft propulsion system which couples an oil-free turboshaft engine to a highly loaded gearbox that provides axial load support for the power turbine can be designed with current laboratory proven technology. Such a system can provide up to 60% weight reduction of the propulsion system of rotorcraft vehicles. Several technical challenges are apparent at the conceptual design level and should be addressed with current research.
Long-term potentiation and long-term depression: a clinical perspective
Bliss, Timothy V.P.; Cooke, Sam F
2011-01-01
Long-term potentiation and long-term depression are enduring changes in synaptic strength, induced by specific patterns of synaptic activity, that have received much attention as cellular models of information storage in the central nervous system. Work in a number of brain regions, from the spinal cord to the cerebral cortex, and in many animal species, ranging from invertebrates to humans, has demonstrated a reliable capacity for chemical synapses to undergo lasting changes in efficacy in response to a variety of induction protocols. In addition to their physiological relevance, long-term potentiation and depression may have important clinical applications. A growing insight into the molecular mechanisms underlying these processes, and technological advances in non-invasive manipulation of brain activity, now puts us at the threshold of harnessing long-term potentiation and depression and other forms of synaptic, cellular and circuit plasticity to manipulate synaptic strength in the human nervous system. Drugs may be used to erase or treat pathological synaptic states and non-invasive stimulation devices may be used to artificially induce synaptic plasticity to ameliorate conditions arising from disrupted synaptic drive. These approaches hold promise for the treatment of a variety of neurological conditions, including neuropathic pain, epilepsy, depression, amblyopia, tinnitus and stroke. PMID:21779718
Gochfeld, Michael; Mohr, Sandra
2007-01-01
Increased reliance on subcontractors in all economic sectors is a serious occupational health and safety challenge. Short-term cost savings are offset by long-term liability. Hiring subcontractors brings specialized knowledge but also young, inexperienced, inadequately trained workers onto industrial and hazardous waste sites, which leads to increased rates of accidents and injuries. Reliable data on subcontractor occupational health and safety programs and performance are sparse. The US Department of Energy has an excellent safety culture on paper, but procurement practices and contract language deliver a mixed message—including some safety disincentives. Its biphasic safety outcome data are consistent with underreporting by some subcontractors and underachievement by others. These observations are relevant to the private and public sectors. Occupational health and safety should be viewed as an asset, not merely a cost. PMID:17666686
Gochfeld, Michael; Mohr, Sandra
2007-09-01
Increased reliance on subcontractors in all economic sectors is a serious occupational health and safety challenge. Short-term cost savings are offset by long-term liability. Hiring subcontractors brings specialized knowledge but also young, inexperienced, inadequately trained workers onto industrial and hazardous waste sites, which leads to increased rates of accidents and injuries. Reliable data on subcontractor occupational health and safety programs and performance are sparse. The US Department of Energy has an excellent safety culture on paper, but procurement practices and contract language deliver a mixed message--including some safety disincentives. Its biphasic safety outcome data are consistent with underreporting by some subcontractors and underachievement by others. These observations are relevant to the private and public sectors. Occupational health and safety should be viewed as an asset, not merely a cost.
Long-Term Stability of Mold Compounds and the Influence on Semiconductor Device Reliability
NASA Astrophysics Data System (ADS)
Mahler, Joachim; Mengel, Manfred
2012-07-01
Lifetimes of semiconductor devices are specified according to the products and their applications to ensure safe operation, for instance as part of an automobile product. The long-term stability of the device is strongly dependent on the chip encapsulation and its adhesion to the chip and substrate. Molded silicon strips that act as a model system for molded chips inside semiconductor devices were investigated. Four commercially available mold compounds were applied on silicon strips and stored over 5 years at room temperature (RT), and changes in the thermomechanical behavior were analyzed. After storage, all molded strips exhibited warpage reduction in the range of 11% to 14% at RT with respect to the initial warpage. The temperatures for the stress-free state also changed during storage and were located between 228°C and 235°C for each mold. Additional stress applied to the stored modules, by temperature cycling as well as high-temperature storage, increased the warpage of the molded silicon samples. For further interpretation of measured results, finite-element method calculations were performed.
Cognitive functioning following traumatic brain injury: A five-year follow-up.
Marsh, Nigel V; Ludbrook, Maria R; Gaffaney, Lauren C
2016-01-01
To describe the long-term prevalence and severity of cognitive deficits following significant (i.e., ventilation required for >24 hours) traumatic brain injury. To assess a comprehensive range of cognitive functions using psychometric measures with established normative, reliability, and validity data. A group of 71 adults was assessed at approximately five years (mean = 66 months) following injury. Assessment of cognitive functioning covered the domains of intelligence, attention, verbal and visual memory, visual-spatial construction, and executive functions. Impairment was evident across all domains but prevalence varied both within and between domains. Across aspects of intelligence clinical impairment ranged from 8-25% , attention 39-62% , verbal memory 16-46% , visual memory 23-51% , visual-spatial construction 38% , and executive functions (verbal fluency) 13% . In addition, 3-23% of performances across the measures were in the borderline range, suggesting a high prevalence of subclinical deficit. Although the prevalence of impairment may vary across cognitive domains, long-term follow-up documented deficits in all six domains. These findings provide further evidence that while improvement of cognitive functioning following significant traumatic brain injury may be possible, recovery of function is unlikely.
Ultrasonic High-Temperature Sensors: Past Experiments and Prospects for Future Use
NASA Astrophysics Data System (ADS)
Laurie, M.; Magallon, D.; Rempe, J.; Wilkins, C.; Pierre, J.; Marquié, C.; Eymery, S.; Morice, R.
2010-09-01
Ultrasonic thermometry sensors (UTS) have been intensively studied in the past to measure temperatures from 2080 K to 3380 K. This sensor, which uses the temperature dependence of the acoustic velocity in materials, was developed for experiments in extreme environments. Its major advantages, which are (a) capability of measuring a temperature profile from multiple sensors on a single probe and (b) measurement near the sensor material melting point, can be of great interest when dealing with on-line monitoring of high-temperature safety tests. Ultrasonic techniques were successfully applied in several severe accident related experiments. With new developments of alternative materials, this instrument may be used in a wide range of experimental areas where robustness and compactness are required. Long-term irradiation experiments of nuclear fuel to extremely high burn-ups could benefit from this previous experience. After an overview of UTS technology, this article summarizes experimental work performed to improve the reliability of these sensors. The various designs, advantages, and drawbacks are outlined and future prospects for long-term high-temperature irradiation experiments are discussed.
NASA Technical Reports Server (NTRS)
Bast, Callie C.; Jurena, Mark T.; Godines, Cody R.; Chamis, Christos C. (Technical Monitor)
2001-01-01
This project included both research and education objectives. The goal of this project was to advance innovative research and education objectives in theoretical and computational probabilistic structural analysis, reliability, and life prediction for improved reliability and safety of structural components of aerospace and aircraft propulsion systems. Research and education partners included Glenn Research Center (GRC) and Southwest Research Institute (SwRI) along with the University of Texas at San Antonio (UTSA). SwRI enhanced the NESSUS (Numerical Evaluation of Stochastic Structures Under Stress) code and provided consulting support for NESSUS-related activities at UTSA. NASA funding supported three undergraduate students, two graduate students, a summer course instructor and the Principal Investigator. Matching funds from UTSA provided for the purchase of additional equipment for the enhancement of the Advanced Interactive Computational SGI Lab established during the first year of this Partnership Award to conduct the probabilistic finite element summer courses. The research portion of this report presents the cumulation of work performed through the use of the probabilistic finite element program, NESSUS, Numerical Evaluation and Structures Under Stress, and an embedded Material Strength Degradation (MSD) model. Probabilistic structural analysis provided for quantification of uncertainties associated with the design, thus enabling increased system performance and reliability. The structure examined was a Space Shuttle Main Engine (SSME) fuel turbopump blade. The blade material analyzed was Inconel 718, since the MSD model was previously calibrated for this material. Reliability analysis encompassing the effects of high temperature and high cycle fatigue, yielded a reliability value of 0.99978 using a fully correlated random field for the blade thickness. The reliability did not change significantly for a change in distribution type except for a change in distribution from Gaussian to Weibull for the centrifugal load. The sensitivity factors determined to be most dominant were the centrifugal loading and the initial strength of the material. These two sensitivity factors were influenced most by a change in distribution type from Gaussian to Weibull. The education portion of this report describes short-term and long-term educational objectives. Such objectives serve to integrate research and education components of this project resulting in opportunities for ethnic minority students, principally Hispanic. The primary vehicle to facilitate such integration was the teaching of two probabilistic finite element method courses to undergraduate engineering students in the summers of 1998 and 1999.
Anomalous Low States and Long Term Variability in the Black Hole Binary LMC X-3
NASA Technical Reports Server (NTRS)
Smale, Alan P.; Boyd, Patricia T.
2012-01-01
Rossi X-my Timing Explorer observations of the black hole binary LMC X-3 reveal an extended very low X-ray state lasting from 2003 December 13 until 2004 March 18, unprecedented both in terms of its low luminosity (>15 times fainter than ever before seen in this source) and long duration (approx 3 times longer than a typical low/hard state excursion). During this event little to no source variability is observed on timescales of approx hours-weeks, and the X-ray spectrum implies an upper limit of 1.2 x 10(exp 35) erg/s, Five years later another extended low state occurs, lasting from 2008 December 11 until 2009 June 17. This event lasts nearly twice as long as the first, and while significant variability is observed, the source remains reliably in the low/hard spectral state for the approx 188 day duration. These episodes share some characteristics with the "anomalous low states" in the neutron star binary Her X-I. The average period and amplitude of the Variability of LMC X-3 have different values between these episodes. We characterize the long-term variability of LMC X-3 before and after the two events using conventional and nonlinear time series analysis methods, and show that, as is the case in Her X-I, the characteristic amplitude of the variability is related to its characteristic timescale. Furthermore, the relation is in the same direction in both systems. This suggests that a similar mechanism gives rise to the long-term variability, which in the case of Her X-I is reliably modeled with a tilted, warped precessing accretion disk.
Saub, R; Locker, D; Allison, P
2008-09-01
To compare two methods of developing short forms of the Malaysian Oral Health Impact Profile (OHIP-M) measure. Cross sectional data obtained using the long form of the OHIP-M was used to produce two types of OHIP-M short forms, derived using two different methods; namely regression and item frequency methods. The short version derived using a regression method is known as Reg-SOHIP(M) and that derived using a frequency method is known as Freq-SOHIP(M). Both short forms contained 14 items. These two forms were then compared in terms of their content, scores, reliability, validity and the ability to distinguish between groups. Out of 14 items, only four were in common. The form derived from the frequency method contained more high prevalence items and higher scores than the form derived from the regression method. Both methods produced a reliable and valid measure. However, the frequency method produced a measure, which was slightly better in terms of distinguishing between groups. Regardless of the method used to produce the measures, both forms performed equally well when tested for their cross-sectional psychometric properties.
DOT National Transportation Integrated Search
2010-01-01
Transportation Asset Management (TAM) has long been recognized as a sound, long-term approach to managing infrastructure. It provides decision makers with a rational, long-term systematic process for making difficult and complex decisions about how t...
Comparing Strategic Knowledge Gaps for Human Mars Settlement vs. Exploration
NASA Astrophysics Data System (ADS)
Mackenzie, B. A.
2012-06-01
We list knowledge needed to establish a permanent Mars base, compared that for round-trip human exploration missions. Topics include: site selection, reliable access to water, long term effects of contaminations, and in-situ materials production.
van Leeuwen, Marieke; Kieffer, Jacobien M; Efficace, Fabio; Fosså, Sophie D; Bolla, Michel; Collette, Laurence; Colombel, Marc; De Giorgi, Ugo; Holzner, Bernhard; van de Poll-Franse, Lonneke V; van Poppel, Hendrik; White, Jeff; de Wit, Ronald; Osanto, Susanne; Aaronson, Neil K
2017-05-11
Understanding of the physical, functional and psychosocial health problems and needs of cancer survivors requires cross-national and cross-cultural standardization of health-related quality of life (HRQoL) questionnaires that capture the full range of issues relevant to cancer survivors. To our knowledge, only one study has investigated in a comprehensive way whether a questionnaire used to evaluate HRQoL in cancer patients under active treatment is also reliable and valid when used among (long-term) cancer survivors. In this study we evaluated, in an international context, the psychometrics of HRQoL questionnaires for use among long-term, disease-free, survivors of testicular and prostate cancer. In this cross-sectional study, we recruited long-term survivors of testicular and prostate cancer from Northern and Southern Europe and from the United Kingdom who had participated in two phase III EORTC clinical trials. Participants completed the SF-36 Health Survey, the EORTC QLQ-C30 questionnaire, the QLQ-PR25 (for prostate cancer) or the QLQ-TC26 (for testicular cancer) questionnaires, and the Impact of Cancer questionnaire. Testicular cancer survivors also completed subscales from the Nordic Questionnaire for Monitoring the Age Diverse Workforce. Two hundred forty-two men (66% response rate) were recruited into the study. The average time since treatment was more than 10 years. Overall, there were few missing questionnaire data, although scales related to sexuality, satisfaction with care and relationship concerns of men without partners were missing in more than 10% of cases. Debriefing showed that in general the questionnaires were accepted well. Many of the survivors scored at the upper extremes of the questionnaires, resulting in floor and ceiling effects in 64% of the scales. All of the questionnaires investigated met the threshold of 0.70 for group level reliability, with the exception of the QLQ-TC26 (mean reliability .64) and the QLQ-PR25 (mean reliability .69). The questionnaires were able to discriminate clearly between patients with and without comorbid conditions. The currently available HRQoL questionnaires exhibit acceptable psychometric properties and were well received by patients, but additional efforts are needed to ensure that the full range of survivor-specific issues is assessed.
Initiation process of earthquakes and its implications for seismic hazard reduction strategy.
Kanamori, H
1996-04-30
For the average citizen and the public, "earthquake prediction" means "short-term prediction," a prediction of a specific earthquake on a relatively short time scale. Such prediction must specify the time, place, and magnitude of the earthquake in question with sufficiently high reliability. For this type of prediction, one must rely on some short-term precursors. Examinations of strain changes just before large earthquakes suggest that consistent detection of such precursory strain changes cannot be expected. Other precursory phenomena such as foreshocks and nonseismological anomalies do not occur consistently either. Thus, reliable short-term prediction would be very difficult. Although short-term predictions with large uncertainties could be useful for some areas if their social and economic environments can tolerate false alarms, such predictions would be impractical for most modern industrialized cities. A strategy for effective seismic hazard reduction is to take full advantage of the recent technical advancements in seismology, computers, and communication. In highly industrialized communities, rapid earthquake information is critically important for emergency services agencies, utilities, communications, financial companies, and media to make quick reports and damage estimates and to determine where emergency response is most needed. Long-term forecast, or prognosis, of earthquakes is important for development of realistic building codes, retrofitting existing structures, and land-use planning, but the distinction between short-term and long-term predictions needs to be clearly communicated to the public to avoid misunderstanding.
How reliable and accurate is the AO/OTA comprehensive classification for adult long-bone fractures?
Meling, Terje; Harboe, Knut; Enoksen, Cathrine H; Aarflot, Morten; Arthursson, Astvaldur J; Søreide, Kjetil
2012-07-01
Reliable classification of fractures is important for treatment allocation and study comparisons. The overall accuracy of scoring applied to a general population of fractures is little known. This study aimed to investigate the accuracy and reliability of the comprehensive Arbeitsgemeinschaft für Osteosynthesefragen/Orthopedic Trauma Association classification for adult long-bone fractures and identify factors associated with poor coding agreement. Adults (>16 years) with long-bone fractures coded in a Fracture and Dislocation Registry at the Stavanger University Hospital during the fiscal year 2008 were included. An unblinded reference code dataset was generated for the overall accuracy assessment by two experienced orthopedic trauma surgeons. Blinded analysis of intrarater reliability was performed by rescoring and of interrater reliability by recoding of a randomly selected fracture sample. Proportion of agreement (PA) and kappa (κ) statistics are presented. Uni- and multivariate logistic regression analyses of factors predicting accuracy were performed. During the study period, 949 fractures were included and coded by 26 surgeons. For the intrarater analysis, overall agreements were κ = 0.67 (95% confidence interval [CI]: 0.64-0.70) and PA 69%. For interrater assessment, κ = 0.67 (95% CI: 0.62-0.72) and PA 69%. The accuracy of surgeons' blinded recoding was κ = 0.68 (95% CI: 0.65- 0.71) and PA 68%. Fracture type, frequency of the fracture, and segment fractured significantly influenced accuracy whereas the coder's experience did not. Both the reliability and accuracy of the comprehensive Arbeitsgemeinschaft für Osteosynthesefragen/Orthopedic Trauma Association classification for long-bone fractures ranged from substantial to excellent. Variations in coding accuracy seem to be related more to the fracture itself than the surgeon. Diagnostic study, level I.
Mallet, Cindy; Ilharreborde, Brice; Jehanno, Pascal; Litzelmann, Estelle; Valenti, Philippe; Mazda, Keyvan; Penneçot, Georges-François; Fitoussi, Franck
2013-03-01
Many commissural reconstruction techniques have been described for the treatment of syndactyly. This study is the first to compare long-term results of 2 commissural dorsal flap procedures (T-flap and omega-flap). Fifty-nine web-spaces in 39 patients, operated on between 1991 and 2008, were retrospectively analyzed. Thirty-six T-flap and 23 omega-flap procedures were performed using full-thickness skin graft in every case for digital resurfacing. Factors that could affect the long-term outcome were collected, including development of web-creep, clinodactyly, and flexion contracture. Patients were reviewed with a mean follow-up of 5 years and 8 months. Preoperative complexity of syndactyly influenced the development of clinodactyly and flexion contracture. Among the patients who developed clinodactyly, 96% had surgery for complex syndactyly. No difference was found between the 2 flap methods concerning digital deformation and mobility. However, web-creep occurred more frequently after T-flap than after omega-flap procedures (17% vs. 5%). The combination of either dorsal commissural T-flaps or omega-flaps with full-thickness graft to resurface digits is a reliable technique for the treatment of syndactyly with satisfactory functional and cosmetic results. Long-term results are not influenced by the type of flap. Nevertheless, the omega-flap technique, using 2 triangular lateral-palmar flaps, avoids use of skin graft to cover lateral-palmar aspects of the new commissure, consequently reducing the incidence of web-creep. In cases of syndactyly, the primary prognostic factor is whether the patient has simple or complex syndactyly. In complex syndactyly, the risk of long-term unfavorable results is higher. When complex complicated syndactyly is involved, postoperative complication rates increase. Level III.
Mid- and long-term runoff predictions by an improved phase-space reconstruction model.
Hong, Mei; Wang, Dong; Wang, Yuankun; Zeng, Xiankui; Ge, Shanshan; Yan, Hengqian; Singh, Vijay P
2016-07-01
In recent years, the phase-space reconstruction method has usually been used for mid- and long-term runoff predictions. However, the traditional phase-space reconstruction method is still needs to be improved. Using the genetic algorithm to improve the phase-space reconstruction method, a new nonlinear model of monthly runoff is constructed. The new model does not rely heavily on embedding dimensions. Recognizing that the rainfall-runoff process is complex, affected by a number of factors, more variables (e.g. temperature and rainfall) are incorporated in the model. In order to detect the possible presence of chaos in the runoff dynamics, chaotic characteristics of the model are also analyzed, which shows the model can represent the nonlinear and chaotic characteristics of the runoff. The model is tested for its forecasting performance in four types of experiments using data from six hydrological stations on the Yellow River and the Yangtze River. Results show that the medium-and long-term runoff is satisfactorily forecasted at the hydrological stations. Not only is the forecasting trend accurate, but also the mean absolute percentage error is no more than 15%. Moreover, the forecast results of wet years and dry years are both good, which means that the improved model can overcome the traditional ''wet years and dry years predictability barrier,'' to some extent. The model forecasts for different regions are all good, showing the universality of the approach. Compared with selected conceptual and empirical methods, the model exhibits greater reliability and stability in the long-term runoff prediction. Our study provides a new thinking for research on the association between the monthly runoff and other hydrological factors, and also provides a new method for the prediction of the monthly runoff. Copyright © 2015 Elsevier Inc. All rights reserved.
Wilkinson, Amy A; Dennis, Maureen; Simic, Nevena; Taylor, Margot J; Morgan, Benjamin R; Frndova, Helena; Choong, Karen; Campbell, Craig; Fraser, Douglas; Anderson, Vicki; Guerguerian, Anne-Marie; Schachar, Russell; Hutchison, Jamie
2017-07-24
Children with traumatic brain injury (TBI) are frequently at risk of long-term impairments of attention and executive functioning but these problems are difficult to predict. Although deficits have been reported to vary with injury severity, age at injury and sex, prognostication of outcome remains imperfect at a patient-specific level. The objective of this proof of principle study was to evaluate a variety of patient variables, along with six brain-specific and inflammatory serum protein biomarkers, as predictors of long-term cognitive outcome following paediatric TBI. Outcome was assessed in 23 patients via parent-rated questionnaires related to attention deficit hyperactivity disorder (ADHD) and executive functioning, using the Conners 3rd Edition Rating Scales (Conners-3) and Behaviour Rating Inventory of Executive Function (BRIEF) at a mean time since injury of 3.1 years. Partial least squares (PLS) analyses were performed to identify factors measured at the time of injury that were most closely associated with outcome on (1) the Conners-3 and (2) the Behavioural Regulation Index (BRI) and (3) Metacognition Index (MI) of the BRIEF. Higher levels of neuron specific enolase (NSE) and lower levels of soluble neuron cell adhesion molecule (sNCAM) were associated with higher scores on the inattention, hyperactivity/impulsivity and executive functioning scales of the Conners-3, as well as working memory and initiate scales of the MI from the BRIEF. Higher levels of NSE only were associated with higher scores on the inhibit scale of the BRI. NSE and sNCAM show promise as reliable, early predictors of long-term attention-related and executive functioning problems following paediatric TBI.
ZERODUR®: new stress corrosion data improve strength fatigue prediction
NASA Astrophysics Data System (ADS)
Hartmann, Peter; Kleer, Günter; Rist, Tobias
2015-09-01
The extremely low thermal expansion glass ceramic ZERODUR® finds more and more applications as sophisticated light weight structures with thin ribs or as thin shells. Quite often they will be subject to higher mechanical loads such as rocket launches or modulating wobbling vibrations. Designing such structures requires calculation methods and data taking into account their long term fatigue. With brittle materials fatigue is not only given by the material itself but to a high extent also by its surface condition and the environmental media especially humidity. This work extends the latest data and information gathered on the bending strength of ZERODUR® with new results concerning its long term behavior under tensile stress. The parameter needed for prediction calculations which combines the influences of time and environmental media is the stress corrosion constant n. Results of the past differ significantly from each other. In order to obtain consistent data the stress corrosion constant has been measured with the method comparing the breakage statistical distributions at different stress increase rates. For better significance the stress increase rate was varied over four orders of magnitude from 0.004 MPa/s to 40 MPa/s. Experiments were performed under normal humidity for long term earth bound applications and under nitrogen atmosphere as equivalent to dry environment occurring for example with telescopes in deserts and also equivalent to vacuum for space applications. As shown earlier the bending strength of diamond ground surfaces of ZERODUR® can be represented with a three parameter Weibull distribution. Predictions on the long term strength change of ZERODUR® structures under tensile stress are possible with reduced uncertainty if Weibull threshold strength values are considered and more reliable stress corrosion constant data are applied.
NASA Astrophysics Data System (ADS)
Sin, Yongkun; Ayvazian, Talin; Brodie, Miles; Lingley, Zachary
2018-03-01
High-power single-mode (SM) and multi-mode (MM) InGaAs-AlGaAs strained quantum well (QW) lasers are critical components for both terrestrial and space satellite communications systems. Since these lasers predominantly fail by catastrophic and sudden degradation due to catastrophic optical damage (COD), it is especially crucial for space satellite applications to investigate reliability, failure modes, precursor signatures of failure, and degradation mechanisms of these lasers. Our group reported a new failure mode in MM and SM InGaAs-AlGaAs strained QW lasers in 2009 and 2016, respectively. Our group also reported in 2017 that bulk failure due to catastrophic optical bulk damage (COBD) is the dominant failure mode of both SM and MM lasers that were subject to long-term life-tests. For the present study, we continued our physics of failure investigation by performing long-term life-tests followed by failure mode analysis (FMA) using nondestructive and destructive micro-analytical techniques. We performed long-term accelerated life-tests on state-of-the-art SM and MM InGaAs- AlGaAs strained QW lasers under ACC mode. Our life-tests have accumulated over 25,000 test hours for SM lasers and over 35,000 test hours for MM lasers. We first employed electron beam induced current (EBIC) technique to identify failure modes of degraded SM lasers by observing dark line defects. All the SM failures that we studied showed catastrophic and sudden degradation and all of these failures were bulk failures. Since degradation mechanisms responsible for COBD are still not well understood, we also employed other techniques including focused ion beam (FIB) and high-resolution TEM to further study dark line defects and dislocations in post-aged lasers. Keywor
NASA Astrophysics Data System (ADS)
Liang, Zhongmin; Li, Yujie; Hu, Yiming; Li, Binquan; Wang, Jun
2017-06-01
Accurate and reliable long-term forecasting plays an important role in water resources management and utilization. In this paper, a hybrid model called SVR-HUP is presented to predict long-term runoff and quantify the prediction uncertainty. The model is created based on three steps. First, appropriate predictors are selected according to the correlations between meteorological factors and runoff. Second, a support vector regression (SVR) model is structured and optimized based on the LibSVM toolbox and a genetic algorithm. Finally, using forecasted and observed runoff, a hydrologic uncertainty processor (HUP) based on a Bayesian framework is used to estimate the posterior probability distribution of the simulated values, and the associated uncertainty of prediction was quantitatively analyzed. Six precision evaluation indexes, including the correlation coefficient (CC), relative root mean square error (RRMSE), relative error (RE), mean absolute percentage error (MAPE), Nash-Sutcliffe efficiency (NSE), and qualification rate (QR), are used to measure the prediction accuracy. As a case study, the proposed approach is applied in the Han River basin, South Central China. Three types of SVR models are established to forecast the monthly, flood season and annual runoff volumes. The results indicate that SVR yields satisfactory accuracy and reliability at all three scales. In addition, the results suggest that the HUP cannot only quantify the uncertainty of prediction based on a confidence interval but also provide a more accurate single value prediction than the initial SVR forecasting result. Thus, the SVR-HUP model provides an alternative method for long-term runoff forecasting.
Autobiographical Memory and ECT: Don’t Throw Out the Baby
Sackeim, Harold A.
2014-01-01
Retrograde amnesia for autobiographical information is the most critical side effect of ECT. Much, if not most, modern research demonstrating long-term autobiographical amnesia following ECT has used either the Columbia University Autobiographical Memory Interview (CUAMI) or the short form of this scale (CUAMI-SF). Semkovska and McLoughlin claimed that studies using these instruments should be dismissed and the findings ignored due to a lack of normative data, as well as concerns about the reliability and validity of these instruments. In this commentary, the development and use of these scales is reviewed. It is shown that Semkovska and McLoughlin’s critique is factually incorrect, as normative data were simultaneously collected in virtually all studies using these instruments. Furthermore, there is substantial evidence supporting the reliability and validity of these scales. Indeed, these instruments are the only neuropsychological tests repeatedly shown to covary with patient self-evaluations of ECT’s effects on memory, and have repeatedly demonstrated long-term differences in the magnitude of amnesia as a function of ECT technique. Findings with the CUAMI and CUAMI-SF provide key evidence regarding ECT’s cognitive side effect profile. It is inaccurate and inadvisable to continue to deny that ECT can exert long-term adverse effects in this domain. PMID:24755727
A study of the reliability of the Nociception Coma Scale.
Riganello, F; Cortese, M D; Arcuri, F; Candelieri, A; Guglielmino, F; Dolce, G; Sannita, W G; Schnakers, C
2015-04-01
In this study, we investigated the reliability of the Nociception Coma Scale which has recently been developed to assess nociception in non-communicative, severely brain-injured patients. Prospective cross-sequential study. Semi-intensive care unit and long-term brain injury care. Forty-four patients diagnosed as being in a vegetative state (n=26) or in a minimally conscious state (n=18). Patients were assessed by two experts (rater A and rater B) on two consecutive weeks to measure inter-rater agreement and test-retest reliability. Total scores and subscores of the Nociception Coma Scale. We performed a total of 176 assessments. The inter-rater agreement was moderate for the total scores (k = 0.57) and fair to substantial for the subscores (0.33 ≤ k ≤ 0.62) on week 2. The test-retest reliability was substantial for the total scores (k = 0.66) and moderate to almost perfect for the subscores (0.53 ≤ k ≤ 0.96) for rater A. The inter-rater agreement was weaker on week 1, whereas the test-retest reliability was lower for the least experienced rater (rater B). This study provides further evidence of the psychometric qualities of the Nociception Coma Scale. Future studies should assess the impact of practical experience and background on administration and scoring of the scale. © The Author(s) 2014.
Wennberg, Richard; Cheyne, Douglas
2014-05-01
To assess the reliability of MEG source imaging (MSI) of anterior temporal spikes through detailed analysis of the localization and orientation of source solutions obtained for a large number of spikes that were separately confirmed by intracranial EEG to be focally generated within a single, well-characterized spike focus. MSI was performed on 64 identical right anterior temporal spikes from an anterolateral temporal neocortical spike focus. The effects of different volume conductors (sphere and realistic head model), removal of noise with low frequency filters (LFFs) and averaging multiple spikes were assessed in terms of the reliability of the source solutions. MSI of single spikes resulted in scattered dipole source solutions that showed reasonable reliability for localization at the lobar level, but only for solutions with a goodness-of-fit exceeding 80% using a LFF of 3 Hz. Reliability at a finer level of intralobar localization was limited. Spike averaging significantly improved the reliability of source solutions and averaging 8 or more spikes reduced dependency on goodness-of-fit and data filtering. MSI performed on topographically identical individual spikes from an intracranially defined classical anterior temporal lobe spike focus was limited by low reliability (i.e., scattered source solutions) in terms of fine, sublobar localization within the ipsilateral temporal lobe. Spike averaging significantly improved reliability. MSI performed on individual anterior temporal spikes is limited by low reliability. Reduction of background noise through spike averaging significantly improves the reliability of MSI solutions. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hara, Seth A.; Kim, Brian J.; Kuo, Jonathan T. W.; Lee, Curtis D.; Meng, Ellis; Pikov, Victor
2016-12-01
Objective. Acquisition of reliable and robust neural recordings with intracortical neural probes is a persistent challenge in the field of neuroprosthetics. We developed a multielectrode array technology to address chronic intracortical recording reliability and present in vivo recording results. Approach. The 2 × 2 Parylene sheath electrode array (PSEA) was microfabricated and constructed from only Parylene C and platinum. The probe includes a novel three-dimensional sheath structure, perforations, and bioactive coatings that improve tissue integration and manage immune response. Coatings were applied using a sequential dip-coating method that provided coverage over the entire probe surface and interior of the sheath structure. A sharp probe tip taper facilitated insertion with minimal trauma. Fabricated probes were subject to examination by optical and electron microscopy and electrochemical testing prior to implantation. Main results. 1 × 2 arrays were successfully fabricated on wafer and then packaged together to produce 2 × 2 arrays. Then, probes having electrode sites with adequate electrochemical properties were selected. A subset of arrays was treated with bioactive coatings to encourage neuronal growth and suppress inflammation and another subset of arrays was implanted in conjunction with a virally mediated expression of Caveolin-1. Arrays were attached to a custom-made insertion shuttle to facilitate precise insertion into the rat motor cortex. Stable electrophysiological recordings were obtained during the period of implantation up to 12 months. Immunohistochemical evaluation of cortical tissue around individual probes indicated a strong correlation between the electrophysiological performance of the probes and histologically observable proximity of neurons and dendritic sprouting. Significance. The PSEA demonstrates the scalability of sheath electrode technology and provides higher electrode count and density to access a greater volume for recording. This study provided support for the importance of creating a supportive biological environment around the probes to promote the long-term electrophysiological performance of flexible probes in the cerebral cortex. In particular, we demonstrated beneficial effects of the Matrigel coating and the long-term expression of Caveolin-1. Furthermore, we provided support to an idea of using an artificial acellular tissue compartment as a way to counteract the walling-off effect of the astrocytic scar formation around the probes as a means of establishing a more intimate and stable neural interface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldberg, Louise F.; Harmon, Anna C.
2015-04-09
This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes. NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. These data currently span the periodmore » from November 10, 2012 through May 31, 2014 and are anticipated to be extended through November 2014. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.« less
Optical silicones for use in harsh operating environments
NASA Astrophysics Data System (ADS)
Riegler, Bill; Bruner, Stephen J.; Elgin, Randall
2004-12-01
The optics industry widely uses silcones for various fiber optic cable potting applications and light emitting diode protection. Optics manufacturers know traditional silicone elastomers, gels, thixotropic gels, and fluids not only perform extremely well in high temperature applications, but also offer refractive index matching so that silicones can transmit light with admirable efficiency. However, because environmental conditions may affect a material's performance over time, one must also consider the conditions the device operates in to ensure long-term reliability. External environments may include exposure to a combination of UV light and temperature, while other environments may expose devices to hydrocarbon based fuels. This paper will delve into the chemistry of silicones and functional groups that lend themselves to properties such as temperature, fuel, and radiation resistance to show shy silicone is the material of choice for optic applications under normally harmful forms of exposure. Data will be presented to examine silicone's performance in these environment.
Integrated function nonimaging concentrating collector tubes for solar thermal energy
NASA Astrophysics Data System (ADS)
Winston, R.; Ogallagher, J. J.
1982-09-01
A substantial improvement in optical efficiency over contemporary external reflector evacuated tube collectors has been achieved by integrating the reflector surface into the outer glass envelope. Described are the design fabrication and test results for a prototype collector based on this concept. A comprehensive test program to measure performance and operational characteristics of a 2 sq m panel (45 tubes) has been completed. Efficiencies above 50% relative to beam at 200 C have been repeatedly demonstrated. Both the instantaneous and long term average performance of this totally stationary solar collector are comparable to those for tracking line focus parabolic troughs. The yield, reliability and stability of performance achieved have been excellent. Subcomponent assemblies and fabrication procedures have been used which are expected to be compatible with high volume production. The collector has a wide variety of applications in the 100 to 300 C range including industrial progress heat, air conditioning and Rankine engine operation.
NASA Astrophysics Data System (ADS)
Papior, Sidsel R.; Weirich, Johannes; Johansen, Mette M.; Jakobsen, Christian; Michieletto, Mattia; Triches, Marco; Kristensen, Torben; Olesen, Anders S.; Petersen, Christian; Andersen, Thomas V.; Maack, Martin D.; Alkeskjold, Thomas T.
2018-02-01
Photonic crystal fiber (PCF) technology for ultrafast fiber amplifiers traditionally uses air holes as key elements for large mode area (LMA) fiber designs. These air holes are crucial for the performance of high-end LMA PCFs, but makes splicing and interfacing more complex. To reduce this complexity in mid-range amplifiers, we present single-mode polarization-maintaining Yb-doped LMA PCFs without air holes for easier splicing into monolithic all-fiber amplifier designs. A 30 μm core all-solid spliceable PCF is presented, and amplification of 1064 nm light above 50 W with an optical to optical efficiency of 80 % is demonstrated. Furthermore, to demonstrate the excellent reliability of PCF based monolithic amplifiers, we demonstrate ultra-longterm performance data of > 35 khrs on a 14 μm core step-index type PCF amplifier with low long-term power degradation slope of < 1.5 % / 10,000 h.
The Effect of Incorrect Reliability Information on Expectations, Perceptions, and Use of Automation.
Barg-Walkow, Laura H; Rogers, Wendy A
2016-03-01
We examined how providing artificially high or low statements about automation reliability affected expectations, perceptions, and use of automation over time. One common method of introducing automation is providing explicit statements about the automation's capabilities. Research is needed to understand how expectations from such introductions affect perceptions and use of automation. Explicit-statement introductions were manipulated to set higher-than (90%), same-as (75%), or lower-than (60%) levels of expectations in a dual-task scenario with 75% reliable automation. Two experiments were conducted to assess expectations, perceptions, compliance, reliance, and task performance over (a) 2 days and (b) 4 days. The baseline assessments showed initial expectations of automation reliability matched introduced levels of expectation. For the duration of each experiment, the lower-than groups' perceptions were lower than the actual automation reliability. However, the higher-than groups' perceptions were no different from actual automation reliability after Day 1 in either study. There were few differences between groups for automation use, which generally stayed the same or increased with experience using the system. Introductory statements describing artificially low automation reliability have a long-lasting impact on perceptions about automation performance. Statements including incorrect automation reliability do not appear to affect use of automation. Introductions should be designed according to desired outcomes for expectations, perceptions, and use of the automation. Low expectations have long-lasting effects. © 2015, Human Factors and Ergonomics Society.
Designing learning environments to promote student learning: ergonomics in all but name.
Smith, Thomas J
2013-01-01
This report introduces evidence for the conclusion that a common theme underlies almost all proposed solutions for improving the performance of K-12 students, namely their reliance on the design of educational system environments, features and operations. Two categories of design factors impacting such performance are addressed: (1) 9 factors reliably shown to have a strong influence - namely environmental design of classroom and building facilities, longer exposure to learning, cooperative learning designs, early childhood education, teaching quality, nutritional adequacy, participation in physical activity, good physical fitness, and school-community integration; and (2) 11 factors with an equivocal, varied or weak influence - classroom technology, online learning environments, smaller class size, school choice, school funding, school size, school start times, teacher training level, amount of homework, student self-confidence and informal learning. It is concluded that: (1) student learning outcomes, and more broadly the edifice of education itself, are largely defined in terms of an extensive system of design factors and conditions; (2) the time is long overdue for the educational system to acknowledge the central role of E/HF design as the major influence on student performance and learning; and (3) K-12 educators and administrators should emphasize allocation of resources to design factors reliably shown to have a strongly positive impact on student performance, but should treat expenditure on factors with equivocal, varied or weak influence on such performance with more caution and/or skepticism.
Demographic Planning: An Action Approach
ERIC Educational Resources Information Center
Finch, Harold L.; Smith, Joyce
1974-01-01
Community colleges are in a good position to obtain reliable long-term forecasts of future demand. An approach developed at Johnson County Community College in Overland Park, Kansas, has enabled the college to assist other community institutions in their parallel planning efforts. (Author/MLF)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Everett, M.; Davis, P.
LLNL and Optiphase resarched fiber optic based fluorescence lifetime instrumentation which, through the incorporation of innovative technology supplied by Optiphase Inc., could lead to a reliable, simplified, and low-cost system mutually compatible with future interests of the company and the long-term stability requirements of ESP sensors.
Haugan, Gørill; Drageset, Jorunn
2014-08-01
Depression and anxiety are particularly common among individuals living in long-term care facilities. Therefore, access to a valid and reliable measure of anxiety and depression among nursing home patients is highly warranted. To investigate the dimensionality, reliability and construct validity of the Hospital Anxiety and Depression scale (HADS) in a cognitively intact nursing home population. Cross-sectional data were collected from two samples; 429 cognitively intact nursing home patients participated, representing 74 different Norwegian nursing homes. Confirmative factor analyses and correlations with selected constructs were used. The two-factor model provided a good fit in Sample1, revealing a poorer fit in Sample2. Good-acceptable measurement reliability was demonstrated, and construct validity was supported. Using listwise deletion the sample sizes were 227 and 187, for Sample1 and Sample2, respectively. Greater sample sizes would have strengthen the statistical power in the tests. The researchers visited the participants to help fill in the questionnaires; this might have introduced some bias into the respondents׳ reporting. The 14 HADS items were part of greater questionnaires. Thus, frail, older NH patients might have tired during the interview causing a possible bias. Low reliability for depression was disclosed, mainly resulting from three items appearing to be inappropriate indicators for depression in this population. Further research is needed exploring which items might perform as more reliably indicators for depression among nursing home patients. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, X; Jiao, Y; Tang, T; Wang, H; Lu, Z
2013-12-19
Intrinsic connectivity networks (ICNs) are composed of spatial components and time courses. The spatial components of ICNs were discovered with moderate-to-high reliability. So far as we know, few studies focused on the reliability of the temporal patterns for ICNs based their individual time courses. The goals of this study were twofold: to investigate the test-retest reliability of temporal patterns for ICNs, and to analyze these informative univariate metrics. Additionally, a correlation analysis was performed to enhance interpretability. Our study included three datasets: (a) short- and long-term scans, (b) multi-band echo-planar imaging (mEPI), and (c) eyes open or closed. Using dual regression, we obtained the time courses of ICNs for each subject. To produce temporal patterns for ICNs, we applied two categories of univariate metrics: network-wise complexity and network-wise low-frequency oscillation. Furthermore, we validated the test-retest reliability for each metric. The network-wise temporal patterns for most ICNs (especially for default mode network, DMN) exhibited moderate-to-high reliability and reproducibility under different scan conditions. Network-wise complexity for DMN exhibited fair reliability (ICC<0.5) based on eyes-closed sessions. Specially, our results supported that mEPI could be a useful method with high reliability and reproducibility. In addition, these temporal patterns were with physiological meanings, and certain temporal patterns were correlated to the node strength of the corresponding ICN. Overall, network-wise temporal patterns of ICNs were reliable and informative and could be complementary to spatial patterns of ICNs for further study. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.
Integration of RAMS in LCC analysis for linear transport infrastructures. A case study for railways.
NASA Astrophysics Data System (ADS)
Calle-Cordón, Álvaro; Jiménez-Redondo, Noemi; Morales-Gámiz, F. J.; García-Villena, F. A.; Garmabaki, Amir H. S.; Odelius, Johan
2017-09-01
Life-cycle cost (LCC) analysis is an economic technique used to assess the total costs associated with the lifetime of a system in order to support decision making in long term strategic planning. For complex systems, such as railway and road infrastructures, the cost of maintenance plays an important role in the LCC analysis. Costs associated with maintenance interventions can be more reliably estimated by integrating the probabilistic nature of the failures associated to these interventions in the LCC models. Reliability, Maintainability, Availability and Safety (RAMS) parameters describe the maintenance needs of an asset in a quantitative way by using probabilistic information extracted from registered maintenance activities. Therefore, the integration of RAMS in the LCC analysis allows obtaining reliable predictions of system maintenance costs and the dependencies of these costs with specific cost drivers through sensitivity analyses. This paper presents an innovative approach for a combined RAMS & LCC methodology for railway and road transport infrastructures being developed under the on-going H2020 project INFRALERT. Such RAMS & LCC analysis provides relevant probabilistic information to be used for condition and risk-based planning of maintenance activities as well as for decision support in long term strategic investment planning.
Soldier Health Habits and the Metabolically Optimized Brain.
Friedl, Karl E; Breivik, Torbjorn J; Carter, Robert; Leyk, Dieter; Opstad, Per Kristian; Taverniers, John; Trousselard, Marion
2016-11-01
Human performance enhancement was the subject of a NATO workshop that considered the direct benefits of individual soldier health and fitness habits to brain health and performance. Some of the important health and fitness include physical activity and purposeful exercise, nutritional intake, sleep and rest behaviors, psychological outlook and mindfulness, and other physiologically based systemic challenges such as thermal exposure. These influences were considered in an integrated framework with insights contributed by each of five participating NATO member countries using representative research to highlight relevant interrelationships. Key conclusions are that (1) understanding the neurobiological bases and consequences of personal health behaviors is a priority for soldier performance research, and this also involves long-term brain health consequences to veterans and (2) health and fitness habits have been underappreciated as reliably effective performance enhancers and these should be preferred targets in the development of scientifically based recommendations for soldier brain health and performance. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Modulation of working memory updating: Does long-term memory lexical association matter?
Artuso, Caterina; Palladino, Paola
2016-02-01
The aim of the present study was to investigate how working memory updating for verbal material is modulated by enduring properties of long-term memory. Two coexisting perspectives that account for the relation between long-term representation and short-term performance were addressed. First, evidence suggests that performance is more closely linked to lexical properties, that is, co-occurrences within the language. Conversely, other evidence suggests that performance is linked more to long-term representations which do not entail lexical/linguistic representations. Our aim was to investigate how these two kinds of long-term memory associations (i.e., lexical or nonlexical) modulate ongoing working memory activity. Therefore, we manipulated (between participants) the strength of the association in letters based on either frequency of co-occurrences (lexical) or contiguity along the sequence of the alphabet (nonlexical). Results showed a cost in working memory updating for strongly lexically associated stimuli only. Our findings advance knowledge of how lexical long-term memory associations between consonants affect working memory updating and, in turn, contribute to the study of factors which impact the updating process across memory systems.
NASA Astrophysics Data System (ADS)
Gao, Zhouzheng; Ge, Maorong; Shen, Wenbin; Zhang, Hongping; Niu, Xiaoji
2017-11-01
Single-frequency precise point positioning (SF-PPP) is a potential precise positioning technique due to the advantages of the high accuracy in positioning after convergence and the low cost in operation. However, there are still challenges limiting its applications at present, such as the long convergence time, the low reliability, and the poor satellite availability and continuity in kinematic applications. In recent years, the achievements in the dual-frequency PPP have confirmed that its performance can be significantly enhanced by employing the slant ionospheric delay and receiver differential code bias (DCB) constraint model, and the multi-constellation Global Navigation Satellite Systems (GNSS) data. Accordingly, we introduce the slant ionospheric delay and receiver DCB constraint model, and the multi-GNSS data in SF-PPP modular together. In order to further overcome the drawbacks of SF-PPP in terms of reliability, continuity, and accuracy in the signal easily blocking environments, the inertial measurements are also adopted in this paper. Finally, we form a new approach to tightly integrate the multi-GNSS single-frequency observations and inertial measurements together to ameliorate the performance of the ionospheric delay and receiver DCB-constrained SF-PPP. In such model, the inter-system bias between each two GNSS systems, the inter-frequency bias between each two GLONASS frequencies, the hardware errors of the inertial sensors, the slant ionospheric delays of each user-satellite pair, and the receiver DCB are estimated together with other parameters in a unique Kalman filter. To demonstrate its performance, the multi-GNSS and low-cost inertial data from a land-borne experiment are analyzed. The results indicate that visible positioning improvements in terms of accuracy, continuity, and reliability can be achieved in both open-sky and complex conditions while using the proposed model in this study compared to the conventional GPS SF-PPP.
Experience Transitioning Models and Data at the NOAA Space Weather Prediction Center
NASA Astrophysics Data System (ADS)
Berger, Thomas
2016-07-01
The NOAA Space Weather Prediction Center has a long history of transitioning research data and models into operations and with the validation activities required. The first stage in this process involves demonstrating that the capability has sufficient value to customers to justify the cost needed to transition it and to run it continuously and reliably in operations. Once the overall value is demonstrated, a substantial effort is then required to develop the operational software from the research codes. The next stage is to implement and test the software and product generation on the operational computers. Finally, effort must be devoted to establishing long-term measures of performance, maintaining the software, and working with forecasters, customers, and researchers to improve over time the operational capabilities. This multi-stage process of identifying, transitioning, and improving operational space weather capabilities will be discussed using recent examples. Plans for future activities will also be described.
Giovannelli, D; Abballe, F
2005-08-26
A method has been developed which allows simultaneous determination of three linear alkyl trimethylammonium salts. Dodecyltrimethylammonium chloride, tetradecyltrimethylammonium bromide and hexadecyltrimethylammonium chloride are widely used as main active ingredients of lysing reagents for blood cell analyzers which perform white blood cells differential determination into two or more sub-populations by impedance analysis. The ion-pair on styrene-divinyl benzene chromatographic phase looks like a suitable, reliable and long term stable tool for separation of such quaternary compounds. The detection based on suppressed conductivity was chosen because of the lack of significance chromophores. A micromembrane suppressor device compatible with high solvent concentration (up to 80%) was used in order to minimize the conductivity background before the detection. In the present work we show how the chemical post column derivatization makes the alkyl chain detectable also by UV direct detection at 210 nm.
Leifker, Feea R.; Patterson, Thomas L.; Bowie, Christopher R.; Mausbach, Brent T.; Harvey, Philip D.
2010-01-01
Performance-based measures of the ability to perform social and everyday living skills are being more widely used to assess functional capacity in people with serious mental illnesses such as schizophrenia and bipolar disorder. Since they are also being used as outcome measures in pharmacological and cognitive remediation studies aimed at cognitive impairments in schizophrenia, understanding their measurement properties and potential sensitivity to change is important. In this study, the test-retest reliability, practice effects, and reliable change indices of two different performance-based functional capacity measures, the UCSD Performance-based skills assessment (UPSA) and Social skills performance assessment (SSPA) were examined over several different retest intervals in two different samples of people with schizophrenia (n’s=238 and 116) and a healthy comparison sample (n=109). These psychometric properties were compared to those of a neuropsychological assessment battery. Test-retest reliabilities of the long form of the UPSA ranged from r=.63 to r=.80 over follow-up periods up to 36 months in people with schizophrenia, while brief UPSA reliabilities ranged from r=.66 to r=.81. Test-retest reliability of the NP performance scores ranged from r=.77 to r=.79. Test-retest reliabilities of the UPSA were lower in healthy controls, while NP performance was slightly more reliable. SSPA test-retest reliability was lower. Practice effect sizes ranged from .05 to .16 for the UPSA and .07 to .19 for the NP assessment in patients, with HC having more practice effects. Reliable change intervals were consistent across NP and both FC measures, indicating equal potential for detection of change. These performance-based measures of functional capacity appear to have similar potential to be sensitive to change compared to NP performance in people with schizophrenia. PMID:20399613
Oerbekke, Michiel S; Stukstette, Mirelle J; Schütte, Kurt; de Bie, Rob A; Pisters, Martijn F; Vanwanseele, Benedicte
2017-01-01
The OpenGo seems promising to take gait analysis out of laboratory settings due to its capability of long-term measurements and mobility. However, the OpenGo's concurrent validity and reliability need to be assessed to determine if the instrument is suitable for validation in patient samples. Twenty healthy volunteers participated. Center of pressure data were collected under eyes open and closed conditions with participants performing unilateral stance trials on the gold standard (AMTI OR6-7 force plate) while wearing the OpenGo. Temporal gait data (stance time, gait cycle time, and cadence) were collected at a self-selected comfortable walking speed with participants performing test-retest trials on an instrumented treadmill while wearing the OpenGo. Validity was assessed using Bland-Altman plots. Reliability was assessed with Intraclass Correlation Coefficient (2,1) and smallest detectable changes were calculated. Negative means of differences were found in all measured parameters, illustrating lower scores for the OpenGo on average. The OpenGo showed negative upper limits of agreement in center of pressure parameters on the mediolateral axis. Temporal reliability ICCs ranged from 0.90-0.93. Smallest detectable changes for both stance times were 0.04 (left) and 0.05 (right) seconds, for gait cycle time 0.08s, and for cadence 4.5 steps per minute. The OpenGo is valid and reliable for the measurement of temporal gait parameters during walking. Measurements of center of pressure parameters during unilateral stance are not considered valid. The OpenGo seems a promising instrument for clinically screening and monitoring temporal gait parameters in patients, however validation in patient populations is needed. Copyright © 2016 Elsevier B.V. All rights reserved.
3D printed cellular solid outperforms traditional stochastic foam in long-term mechanical response
Maiti, A.; Small, W.; Lewicki, J.; ...
2016-04-27
3D printing of polymeric foams by direct-ink-write is a recent technological breakthrough that enables the creation of versatile compressible solids with programmable microstructure, customizable shapes, and tunable mechanical response including negative elastic modulus. However, in many applications the success of these 3D printed materials as a viable replacement for traditional stochastic foams critically depends on their mechanical performance and micro-architectural stability while deployed under long-term mechanical strain. To predict the long-term performance of the two types of foams we employed multi-year-long accelerated aging studies under compressive strain followed by a time-temperature-superposition analysis using a minimum-arc-length-based algorithm. The resulting master curvesmore » predict superior long-term performance of the 3D printed foam in terms of two different metrics, i.e., compression set and load retention. To gain deeper understanding, we imaged the microstructure of both foams using X-ray computed tomography, and performed finite-element analysis of the mechanical response within these microstructures. As a result, this indicates a wider stress variation in the stochastic foam with points of more extreme local stress as compared to the 3D printed material, which might explain the latter’s improved long-term stability and mechanical performance.« less
3D printed cellular solid outperforms traditional stochastic foam in long-term mechanical response
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maiti, A.; Small, W.; Lewicki, J.
3D printing of polymeric foams by direct-ink-write is a recent technological breakthrough that enables the creation of versatile compressible solids with programmable microstructure, customizable shapes, and tunable mechanical response including negative elastic modulus. However, in many applications the success of these 3D printed materials as a viable replacement for traditional stochastic foams critically depends on their mechanical performance and micro-architectural stability while deployed under long-term mechanical strain. To predict the long-term performance of the two types of foams we employed multi-year-long accelerated aging studies under compressive strain followed by a time-temperature-superposition analysis using a minimum-arc-length-based algorithm. The resulting master curvesmore » predict superior long-term performance of the 3D printed foam in terms of two different metrics, i.e., compression set and load retention. To gain deeper understanding, we imaged the microstructure of both foams using X-ray computed tomography, and performed finite-element analysis of the mechanical response within these microstructures. As a result, this indicates a wider stress variation in the stochastic foam with points of more extreme local stress as compared to the 3D printed material, which might explain the latter’s improved long-term stability and mechanical performance.« less
3D printed cellular solid outperforms traditional stochastic foam in long-term mechanical response
NASA Astrophysics Data System (ADS)
Maiti, A.; Small, W.; Lewicki, J. P.; Weisgraber, T. H.; Duoss, E. B.; Chinn, S. C.; Pearson, M. A.; Spadaccini, C. M.; Maxwell, R. S.; Wilson, T. S.
2016-04-01
3D printing of polymeric foams by direct-ink-write is a recent technological breakthrough that enables the creation of versatile compressible solids with programmable microstructure, customizable shapes, and tunable mechanical response including negative elastic modulus. However, in many applications the success of these 3D printed materials as a viable replacement for traditional stochastic foams critically depends on their mechanical performance and micro-architectural stability while deployed under long-term mechanical strain. To predict the long-term performance of the two types of foams we employed multi-year-long accelerated aging studies under compressive strain followed by a time-temperature-superposition analysis using a minimum-arc-length-based algorithm. The resulting master curves predict superior long-term performance of the 3D printed foam in terms of two different metrics, i.e., compression set and load retention. To gain deeper understanding, we imaged the microstructure of both foams using X-ray computed tomography, and performed finite-element analysis of the mechanical response within these microstructures. This indicates a wider stress variation in the stochastic foam with points of more extreme local stress as compared to the 3D printed material, which might explain the latter’s improved long-term stability and mechanical performance.
3D printed cellular solid outperforms traditional stochastic foam in long-term mechanical response
Maiti, A.; Small, W.; Lewicki, J. P.; Weisgraber, T. H.; Duoss, E. B.; Chinn, S. C.; Pearson, M. A.; Spadaccini, C. M.; Maxwell, R. S.; Wilson, T. S.
2016-01-01
3D printing of polymeric foams by direct-ink-write is a recent technological breakthrough that enables the creation of versatile compressible solids with programmable microstructure, customizable shapes, and tunable mechanical response including negative elastic modulus. However, in many applications the success of these 3D printed materials as a viable replacement for traditional stochastic foams critically depends on their mechanical performance and micro-architectural stability while deployed under long-term mechanical strain. To predict the long-term performance of the two types of foams we employed multi-year-long accelerated aging studies under compressive strain followed by a time-temperature-superposition analysis using a minimum-arc-length-based algorithm. The resulting master curves predict superior long-term performance of the 3D printed foam in terms of two different metrics, i.e., compression set and load retention. To gain deeper understanding, we imaged the microstructure of both foams using X-ray computed tomography, and performed finite-element analysis of the mechanical response within these microstructures. This indicates a wider stress variation in the stochastic foam with points of more extreme local stress as compared to the 3D printed material, which might explain the latter’s improved long-term stability and mechanical performance. PMID:27117858
Short-term Operation of Multi-purpose Reservoir using Model Predictive Control
NASA Astrophysics Data System (ADS)
Uysal, Gokcen; Schwanenberg, Dirk; Alvarado Montero, Rodolfo; Sensoy, Aynur; Arda Sorman, Ali
2017-04-01
Operation of water structures especially with conflicting water supply and flood mitigation objectives is under more stress attributed to growing water demand and changing hydro-climatic conditions. Model Predictive Control (MPC) based optimal control solutions has been successfully applied to different water resources applications. In this study, Feedback Control (FBC) and MPC get combined and an improved joint optimization-simulation operating scheme is proposed. Water supply and flood control objectives are fulfilled by incorporating the long term water supply objectives into a time-dependent variable guide curve policy whereas the extreme floods are attenuated by means of short-term optimization based on MPC. A final experiment is carried out to assess the lead time performance and reliability of forecasts in a hindcasting experiment with imperfect, perturbed forecasts. The framework is tested in Yuvacık Dam reservoir where the main water supply reservoir of Kocaeli City in the northwestern part of Turkey (the Marmara region) and it requires a challenging gate operation due to restricted downstream flow conditions.
Long-term cryopreservation of decellularised oesophagi for tissue engineering clinical application.
Urbani, Luca; Maghsoudlou, Panagiotis; Milan, Anna; Menikou, Maria; Hagen, Charlotte Klara; Totonelli, Giorgia; Camilli, Carlotta; Eaton, Simon; Burns, Alan; Olivo, Alessandro; De Coppi, Paolo
2017-01-01
Oesophageal tissue engineering is a therapeutic alternative when oesophageal replacement is required. Decellularised scaffolds are ideal as they are derived from tissue-specific extracellular matrix and are non-immunogenic. However, appropriate preservation may significantly affect scaffold behaviour. Here we aim to prove that an effective method for short- and long-term preservation can be applied to tissue engineered products allowing their translation to clinical application. Rabbit oesophagi were decellularised using the detergent-enzymatic treatment (DET), a combination of deionised water, sodium deoxycholate and DNase-I. Samples were stored in phosphate-buffered saline solution at 4°C (4°C) or slow cooled in medium with 10% Me2SO at -1°C/min followed by storage in liquid nitrogen (SCM). Structural and functional analyses were performed prior to and after 2 and 4 weeks and 3 and 6 months of storage under each condition. Efficient decellularisation was achieved after 2 cycles of DET as determined with histology and DNA quantification, with preservation of the ECM. Only the SCM method, commonly used for cell storage, maintained the architecture and biomechanical properties of the scaffold up to 6 months. On the contrary, 4°C method was effective for short-term storage but led to a progressive distortion and degradation of the tissue architecture at the following time points. Efficient storage allows a timely use of decellularised oesophagi, essential for clinical translation. Here we describe that slow cooling with cryoprotectant solution in liquid nitrogen vapour leads to reliable long-term storage of decellularised oesophageal scaffolds for tissue engineering purposes.
NASA Astrophysics Data System (ADS)
Takaya, Satoshi; Tanamoto, Tetsufumi; Noguchi, Hiroki; Ikegami, Kazutaka; Abe, Keiko; Fujita, Shinobu
2017-04-01
Among the diverse applications of spintronics, security for internet-of-things (IoT) devices is one of the most important. A physically unclonable function (PUF) with a spin device (spin transfer torque magnetoresistive random access memory, STT-MRAM) is presented. Oxide tunnel barrier breakdown is used to realize long-term stability for PUFs. A secure PUF has been confirmed by evaluating the Hamming distance of a 32-bit STT-MRAM-PUF fabricated using 65 nm CMOS technology.
Exercise Countermeasure Hardware Evolution on ISS: The First Decade.
Korth, Deborah W
2015-12-01
The hardware systems necessary to support exercise countermeasures to the deconditioning associated with microgravity exposure have evolved and improved significantly during the first decade of the International Space Station (ISS), resulting in both new types of hardware and enhanced performance capabilities for initial hardware items. The original suite of countermeasure hardware supported the first crews to arrive on the ISS and the improved countermeasure system delivered in later missions continues to serve the astronauts today with increased efficacy. Due to aggressive hardware development schedules and constrained budgets, the initial approach was to identify existing spaceflight-certified exercise countermeasure equipment, when available, and modify it for use on the ISS. Program management encouraged the use of commercial-off-the-shelf (COTS) hardware, or hardware previously developed (heritage hardware) for the Space Shuttle Program. However, in many cases the resultant hardware did not meet the additional requirements necessary to support crew health maintenance during long-duration missions (3 to 12 mo) and anticipated future utilization activities in support of biomedical research. Hardware development was further complicated by performance requirements that were not fully defined at the outset and tended to evolve over the course of design and fabrication. Modifications, ranging from simple to extensive, were necessary to meet these evolving requirements in each case where heritage hardware was proposed. Heritage hardware was anticipated to be inherently reliable without the need for extensive ground testing, due to its prior positive history during operational spaceflight utilization. As a result, developmental budgets were typically insufficient and schedules were too constrained to permit long-term evaluation of dedicated ground-test units ("fleet leader" type testing) to identify reliability issues when applied to long-duration use. In most cases, the exercise unit with the most operational history was the unit installed on the ISS.
Singh, Pramil N; Batech, Michael; Faed, Pegah; Jaceldo-Siegl, Karen; Martins, Marcia; Fraser, Gary E
2014-01-01
We studied Adventist Health Study 2 (AHS-2) cohort members to determine the reliability of long-term recall of adult dietary intake that occurred 33 years ago. Establishing the reliability of these measures supports studies of how dietary exposure across the life course affects risk of cancer and other noncommunicable disease outcomes. Among 1816 AHS-2 cohort members, we conducted a statistical comparison of long-term recall of meat, fish, dairy, and eggs at AHS-2 baseline with their report of current diet 33 years before AHS-2 baseline at an age of 30-60 years. Major findings are as follows: 1) a high correlation for frequency of red meat (R = 0.71), poultry (R = 0.67), and fish (R = 0.60); lower correlations for dairy (R = 0.19) and eggs (R = 0.28); 2) good concordance for dichotomous measures of red meat [sensitivity: 0.70; specificity: 0.92; positive predictive value (PPV): 0.91], poultry (sensitivity: 0.76; specificity: 0.87; PPV: 0.83), fish (sensitivity: 0.61; specificity: 0.93; PPV: 0.89), dairy (sensitivity: 0.95; specificity: 0.57; PPV: 0.99), and eggs (sensitivity: 0.95; specificity: 0.41; PPV: 0.96); negative predictive value for dairy and eggs was poor. Among older AHS-2 cohort members, we found good reliability of recall of red meat, poultry, and fish intake that occurred 33 years earlier.
Mojtahedzadeh, Rita; Mohammadi, Aeen
2016-01-01
Teachers' self-efficacy and development may be conceptualized as their beliefs in their own ability to plan, organize and carry out activities that are required to attain educational goals. In this study, we examined the effect of different medical education training courses (six-day, one- month short- term and sixmonth long- term courses) on perceived self-efficacy and development. This before-after quasi-experimental study was performed on 39 faculty members of Tehran University of Medical Sciences who participated in faculty development courses in 2013. We used valid and reliable scales to measure their perceived self-efficacy and empowerment. The results revealed a significant increase in faculty members' perceived self-efficacy in pre and posttests in one-month and six-month courses, but no significant difference was found in the six-day course (p=0.004, p<0.001 and p=0.235, respectively). These results were the same for perceived empowerment (p<0.001, p<0.001 and p=0.716 for one-month, six-month and six-day courses, respectively). A significant difference was detected in perceived self-efficacy and participant empowerment components based on the training course (p=0.005; Wilk's Λ=0.345, Partial η2=0.413). This study revealed that long- term courses were more effective than the short- term ones. Thus, longitudinal courses are recommended for more effectiveness.
Long-Term Reliability of High Speed SiGe/Si Heterojunction Bipolar Transistors
NASA Technical Reports Server (NTRS)
Ponchak, George E. (Technical Monitor); Bhattacharya, Pallab
2003-01-01
Accelerated lifetime tests were performed on double-mesa structure Si/Si0.7Ge0.3/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175C-275C. Both single- and multiple finger transistors were tested. The single-finger transistors (with 5x20 micron sq m emitter area) have DC current gains approximately 40-50 and f(sub T) and f(sub MAX) of up to 22 GHz and 25 GHz, respectively. The multiple finger transistors (1.4 micron finger width, 9 emitter fingers with total emitter area of 403 micron sq m) have similar DC current gain but f(sub T) of 50 GHz. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REID has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of the devices at room temperature is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation. SiGe/Si based amplifier circuits were also subjected to lifetime testing and we extrapolate MTTF is approximately 1.1_10(exp 6) hours at 125iC junction temperature from the circuit lifetime data.
Testing waterborne chemical carcinogens in fish models requires accurate, reliable, and reproducible exposures. Because carcinogenesis is a chronic toxicological process and is often associated with prolonged latency periods, systems must accommodate lengthy in-life test periods ...
Long-term behavior of GFRP reinforced panels after eight years of field exposure.
DOT National Transportation Integrated Search
2014-06-01
Since 1998, Missouri S&T/University of Missouri-Rolla investigators have been involved in more than 25 bridge repairs and/or new : bridge construction involving composite materials. To date, many of these projects have demonstrated reliable field per...
Report: Ombudsman Review of the Marjol Battery Site, Throop, Pennsylvania
Report #2004-P-00017, May 18, 2004. Over-excavating the Five Foot Seam and ensuring a reliable noncombustible barrier is established between the Five Foot Seam and the Battery Casing Material will sufficiently ensure the long-term safety of the Site.
Improvements of PKU PMECRIS for continuous hundred hours CW proton beam operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, S. X., E-mail: sxpeng@pku.edu.cn; Ren, H. T.; Zhang, T.
2016-02-15
In order to improve the source stability, a long term continuous wave (CW) proton beam experiment has been carried out with Peking University compact permanent magnet 2.45 GHz ECR ion source (PKU PMECRIS). Before such an experiment a lot of improvements and modifications were completed on the source body, the Faraday cup and the PKU ion source test bench. At the beginning of 2015, a continuous operation of PKU PMECRIS for 306 h with more than 50 mA CW beam was carried out after success of many short term tests. No plasma generator failure or high voltage breakdown was observedmore » during that running period and the proton source reliability is near 100%. Total beam availability, which is defined as 35-keV beam-on time divided by elapsed time, was higher than 99% [S. X. Peng et al., Chin. Phys. B 24(7), 075203 (2015)]. A re-inspection was performed after another additional 100 h operation (counting time) and no obvious sign of component failure was observed. Counting the previous source testing time together, this PMECRs longevity is now demonstrated to be greater than 460 h. This paper is mainly concentrated on the improvements for this long term experiment.« less
Carbon Dioxide Removal and the futures market
NASA Astrophysics Data System (ADS)
Lockley, A.; Coffman, D.
2016-12-01
Futures contracts are exchange-traded financial instruments that enable parties to fix a price in advance, for performance on a contract at some later date. Forward contracts also entail future settlement, but they are traded over-the-counter between two independent parties. Both futures and forward contracts are commonly used in commodities trading, as producers seek financial security when planning production. We discuss the use of potential use of exchange-traded futures contracts in Carbon Dioxide Removal (CDR) markets. We conclude that they have one principal advantage (in that they give near-term price security to current polluters), and one principal disadvantage (in that a combination of high price volatility and high trade volume means contracts issued by the private sector may cause systemic economic risk). Accordingly, we note the potential for the development of futures markets in CDR, but urge great caution in the use of this approach. In particular, we consider the use of regulated markets: to ensure contracts are more reliable, and that moral hazard is minimised. Whilst regulation offers generally increased assurances, we identify major insufficiencies with this approach - finding it generally inadequate. In conclusion, we suggest that only governments can realistically support long-term CDR futures markets. We note existing long-term CDR plans by governments, and suggest the use of state-backed futures for supporting these assurances.
Denouel, A; Fauconnier, A; Torre, A
2018-03-01
Women with endometriosis often say that the information doctors give them should be improved. Patient support groups can provide missing information but may lack objectivity, or reliability, and may even generate anxiety or even harm their health. Clear unbiased medical information is the ideal. New patients with endometriosis wish to be taken seriously by primary care physicians, and be referred quickly to a specialist without further unnecessary investigation or delay. The diagnosis of endometriosis should ideally be made quickly, and should clearly specify the nature of the disease, its evolution, and its consequences on quality of life, relationships, and fertility. When choosing a treatment, information should state the risks of each treatment, the risks of recurrence long term, and the therapeutic alternatives. These should include conventional medical treatment, lifestyle adaptation, or alternative therapies. In case of surgery, prior written information should be provided, the likely scar appearance, the short and long term consequences in terms of pain, postoperative recovery time and complication rates. Once the surgery is performed, the degree of endometriotic involvement and the treatment undertaken should be explained. At discharge, patients should be told the expected recovery time, and the consequences of the operation on daily life. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Performance oriented guidance for Mississippi chip seals - volume II.
DOT National Transportation Integrated Search
2013-12-01
A laboratory and field study was conducted related to long term chip seal performance. This reports primary : objective was to initiate development of a long term performance (LTP) test protocol for chip seals focused on : aggregate retention. Key...
DOT National Transportation Integrated Search
2014-05-01
Accurate, consistent, and repeatable distress evaluation surveys can be performed by using the Distress Identification Manual for the Long-Term Pavement Performance Program. Color photographs and drawings illustrate the distresses found in three basi...
Proximal tibial osteotomy. A survivorship analysis.
Ritter, M A; Fechtman, R A
1988-01-01
Proximal tibial osteotomy is generally accepted as a treatment for the patient with unicompartmental arthritis. However, a few reports of the long-term results of this procedure are available in the literature, and none have used the technique known as survivorship analysis. This technique has an advantage over conventional analysis because it does not exclude patients for inadequate follow-up, loss to follow-up, or patient death. In this study, survivorship analysis was applied to 78 proximal tibial osteotomies, performed exclusively by the senior author for the correction of a preoperative varus deformity, and a survival curve was constructed. It was concluded that the reliable longevity of the proximal tibial osteotomy is approximately 6 years.
Nickel hydrogen low Earth orbit life testing
NASA Technical Reports Server (NTRS)
Badcock, C. C.; Haag, R. L.
1986-01-01
A program to demonstrate the long term reliability of NiH2 cells in low Earth orbits (LEO) and support use in mid-altitude orbits (MAO) was initiated. Both 3.5 and 4.5 inch diameter nickel hydrogen cells are included in the test plan. Cells from all U.S. vendors are to be tested. The tests will be performed at -5 and 10 C at 40 and 60% DOD for LEO orbit and 10 C and 80% DOD for MAO orbit simulations. The goals of the testing are 20,000 cycles at 60% DOD and 30,000 cycles at 40% DOD. Cells are presently undergoing acceptance and characterization testing at Naval Weapons Systems Center, Crane.
Direct patterning of organic conductors on knitted textiles for long-term electrocardiography
Takamatsu, Seiichi; Lonjaret, Thomas; Crisp, Dakota; Badier, Jean-Michel; Malliaras, George G.; Ismailova, Esma
2015-01-01
Wearable sensors are receiving a great deal of attention as they offer the potential to become a key technological tool for healthcare. In order for this potential to come to fruition, new electroactive materials endowing high performance need to be integrated with textiles. Here we present a simple and reliable technique that allows the patterning of conducting polymers on textiles. Electrodes fabricated using this technique showed a low impedance contact with human skin, were able to record high quality electrocardiograms at rest, and determine heart rate even when the wearer was in motion. This work paves the way towards imperceptible electrophysiology sensors for human health monitoring. PMID:26446346
Reliability and maintainability assessment factors for reliable fault-tolerant systems
NASA Technical Reports Server (NTRS)
Bavuso, S. J.
1984-01-01
A long term goal of the NASA Langley Research Center is the development of a reliability assessment methodology of sufficient power to enable the credible comparison of the stochastic attributes of one ultrareliable system design against others. This methodology, developed over a 10 year period, is a combined analytic and simulative technique. An analytic component is the Computer Aided Reliability Estimation capability, third generation, or simply CARE III. A simulative component is the Gate Logic Software Simulator capability, or GLOSS. The numerous factors that potentially have a degrading effect on system reliability and the ways in which these factors that are peculiar to highly reliable fault tolerant systems are accounted for in credible reliability assessments. Also presented are the modeling difficulties that result from their inclusion and the ways in which CARE III and GLOSS mitigate the intractability of the heretofore unworkable mathematics.
A Simulation Model for Setting Terms for Performance Based Contract Terms
2010-05-01
torpedo self-noise and the use of ruggedized, embedded, digital micro - processors . The latter capability made it possible for digitally controlled...inventories are: System Reliability, Product Reliability, Operational Availability, Mean Time to Repair (MTTR), Mean Time to Failure ( MTTF ...Failure ( MTTF ) Mean Logistics Delay Time (MLDT) Mean Supply Response Time (MSRT) D ep en de nt M et ric s Mean Accumulated Down Time (MADT
Comparison of three ADHD screening instruments in college students of varying cognitive ability.
Fuller-Killgore, Melissa D; Burlison, Jonathan; Dwyer, William
2013-07-01
To assess three of the better known screeners for Attention Deficit/Hyperactive Disorder (ADHD) and review the relationship between ADHD and cognitive ability. The three ADHD screeners were administered to 111 college students enrolled in a college Introductory Psychology class, on whom ACT scores and total course performance were also available. As a measure of cognitive ability, the Wonderlic Personnel Test (Wonderlic, Inc., 2000) was also administered. Furthermore, self-report data were available from participants who had been diagnosed with ADHD. The three screeners were the Adult ADHD Self-Report Scale (ASRS) (Kessler et al., 2005), the Conners' Adult ADHD Rating Scale-Self-Report: Long Version (CAARS) (Conners, Erhardt, & Sparrow, 1999), and the Brown ADD Scales (Brown, 1996). The results are discussed in terms of the scales' reliability, as well as their relationship to academic aptitude, class performance, and their ability to identify self-reported ADHD diagnoses. All three screeners exhibited acceptable reliability levels. Criterion validity was demonstrated by the relationship between the CAARS's inattention subscale and self-reported cases of ADHD. Criterion validity was also seen in the relationship found between the CAARS's hyperactivity/restlessness subscale and the total course performance even after controlling for cognitive ability. Contrary to past research cognitive ability exhibited a weak but significant relationship with a few screeners and screener subscales.
Reliability of the term 'support' in singing.
Sand, Susanne; Sundberg, Johan
2005-01-01
The usefulness of a term depends on the extent to which it means the same thing to different people. In this investigation we examine the term 'support', commonly used in vocal pedagogy. Singing lessons given by co-author SS to five students at varying stages were recorded on DAT. By listening to these recordings, she selected 42 examples, each a few seconds long, that she found representative of different degrees of support ranging from perfect to nil. These examples were presented in random order to nine experts, all with a professional involvement in singing. Thirteen of the stimuli occurred twice in the test. Intra- and inter-rater reliability were found to be high, Cronbach alpha=0.910, and mean correlation 0.743 (SD 0.137). These data support the assumption that the term support has a similar meaning to voice experts and should thus be useful in voice terminology.
Castagnola, Elisa; Maggiolini, Emma; Ceseracciu, Luca; Ciarpella, Francesca; Zucchini, Elena; De Faveri, Sara; Fadiga, Luciano; Ricci, Davide
2016-01-01
The long-term reliability of neural interfaces and stability of high-quality recordings are still unsolved issues in neuroscience research. High surface area PEDOT-PSS-CNT composites are able to greatly improve the performance of recording and stimulation for traditional intracortical metal microelectrodes by decreasing their impedance and increasing their charge transfer capability. This enhancement significantly reduces the size of the implantable device though preserving excellent electrical performances. On the other hand, the presence of nanomaterials often rises concerns regarding possible health hazards, especially when considering a clinical application of the devices. For this reason, we decided to explore the problem from a new perspective by designing and testing an innovative device based on nanostructured microspheres grown on a thin tether, integrating PEDOT-PSS-CNT nanocomposites with a soft synthetic permanent biocompatible hydrogel. The pHEMA hydrogel preserves the electrochemical performance and high quality recording ability of PEDOT-PSS-CNT coated devices, reduces the mechanical mismatch between soft brain tissue and stiff devices and also avoids direct contact between the neural tissue and the nanocomposite, by acting as a biocompatible protective barrier against potential nanomaterial detachment. Moreover, the spherical shape of the electrode together with the surface area increase provided by the nanocomposite deposited on it, maximize the electrical contact and may improve recording stability over time. These results have a good potential to contribute to fulfill the grand challenge of obtaining stable neural interfaces for long-term applications. PMID:27147944
Kotzampasakis, Dimitrios; Piniara, Anastasia; Themelis, Sotirios; Kotzampasakis, Stylianos; Gabriel, Eustratios; Maroudias, Nikos; Nikolopoulos, Thomas
2017-09-01
The aim of the present study is to assess the long-term effect of classic rhinoplasty on patients' quality of life. Outcomes research. The study included 100 operated patients; there were 34 males and 66 females. The ages ranged between 23 and 57 years old, with a mean of 36.4 years. A minimum of 3 years between the operation and the study was selected to assess the long-term effect of the operation on the patients' quality of life and exclude any short-term impressions. The time elapsed between surgery and the time of the study ranged from 3 to 13 years, with a mean of 6.8 years. Patients were assessed using the Glasgow Benefit Inventory, which has been proven valid and reliable in ear, nose, and throat interventions. From the 100 patients included in the study, 92 reported improvement in their quality of life due to the operation and only eight worsening. In the social support subscale, 97 patients reported better quality of life, and only three patients reported worse quality of life. The patients' overall life markedly improved, reaching a mean of 80% in the Glasgow Benefit Inventory. The present long-term study using a validated and reliable instrument concludes that rhinoplasty improves the quality of life of patients in all sectors. 2c Laryngoscope, 127:2017-2025, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
NASA Astrophysics Data System (ADS)
Perera, Kushan C.; Western, Andrew W.; Robertson, David E.; George, Biju; Nawarathna, Bandara
2016-06-01
Irrigation demands fluctuate in response to weather variations and a range of irrigation management decisions, which creates challenges for water supply system operators. This paper develops a method for real-time ensemble forecasting of irrigation demand and applies it to irrigation command areas of various sizes for lead times of 1 to 5 days. The ensemble forecasts are based on a deterministic time series model coupled with ensemble representations of the various inputs to that model. Forecast inputs include past flow, precipitation, and potential evapotranspiration. These inputs are variously derived from flow observations from a modernized irrigation delivery system; short-term weather forecasts derived from numerical weather prediction models and observed weather data available from automatic weather stations. The predictive performance for the ensemble spread of irrigation demand was quantified using rank histograms, the mean continuous rank probability score (CRPS), the mean CRPS reliability and the temporal mean of the ensemble root mean squared error (MRMSE). The mean forecast was evaluated using root mean squared error (RMSE), Nash-Sutcliffe model efficiency (NSE) and bias. The NSE values for evaluation periods ranged between 0.96 (1 day lead time, whole study area) and 0.42 (5 days lead time, smallest command area). Rank histograms and comparison of MRMSE, mean CRPS, mean CRPS reliability and RMSE indicated that the ensemble spread is generally a reliable representation of the forecast uncertainty for short lead times but underestimates the uncertainty for long lead times.
Recent Advances in Neural Electrode-Tissue Interfaces.
Woeppel, Kevin; Yang, Qianru; Cui, Xinyan Tracy
2017-12-01
Neurotechnology is facing an exponential growth in the recent decades. Neural electrode-tissue interface research has been well recognized as an instrumental component of neurotechnology development. While satisfactory long-term performance was demonstrated in some applications, such as cochlear implants and deep brain stimulators, more advanced neural electrode devices requiring higher resolution for single unit recording or microstimulation still face significant challenges in reliability and longevity. In this article, we review the most recent findings that contribute to our current understanding of the sources of poor reliability and longevity in neural recording or stimulation, including the material failure, biological tissue response and the interplay between the two. The newly developed characterization tools are introduced from electrophysiology models, molecular and biochemical analysis, material characterization to live imaging. The effective strategies that have been applied to improve the interface are also highlighted. Finally, we discuss the challenges and opportunities in improving the interface and achieving seamless integration between the implanted electrodes and neural tissue both anatomically and functionally.
Plint, Simon; Patterson, Fiona
2010-06-01
The UK national recruitment process into general practice training has been developed over several years, with incremental introduction of stages which have been piloted and validated. Previously independent processes, which encouraged multiple applications and produced inconsistent outcomes, have been replaced by a robust national process which has high reliability and predictive validity, and is perceived to be fair by candidates and allocates applicants equitably across the country. Best selection practice involves a job analysis which identifies required competencies, then designs reliable assessment methods to measure them, and over the long term ensures that the process has predictive validity against future performance. The general practitioner recruitment process introduced machine markable short listing assessments for the first time in the UK postgraduate recruitment context, and also adopted selection centre workplace simulations. The key success factors have been identified as corporate commitment to the goal of a national process, with gradual convergence maintaining locus of control rather than the imposition of change without perceived legitimate authority.
Concrete volute pumps: technology review and improvement
NASA Astrophysics Data System (ADS)
Prunières, R.; Longatte, F.; Catelan, F. X.; Philippot, J. M.
2012-11-01
When pumps need to deliver large water flow rates (typically more than 5 m3.s-1), concrete volute pumps (CVP) offer an interesting alternative to standard vertical wet-pit pumps. One of the major advantages of CVP is its simplicity in terms of design, manufacturability and maintainability. In addition, CVP geometrical arrangement allows to reach high performances in terms of hydraulic and mechanical behaviour. These advantages can be specifically appreciated when such pumps are used in the energy field for Power Plants which need high flow rate and reliability, and can lead to important financial savings over the Plant lifetime compared to vertical wet-pit pumps. Finally, as CVP was for a long time limited to total head rise lower than 30 mWC, it was established through CFD analysis that the addition of guide vanes between the impeller and the volute allows to achieve higher head rise without risk.
Dahm, P O; Nitescu, P V; Appelgren, L K; Curelaru, I D
1998-01-01
There is at present no reliable method for long-term treatment of severe pain following complications of total hip arthroplasty. We explored the long-term use of continuous intrathecal opioid/bupivacaine analgesia in a case not amendable to corrective surgery. A 77-year-old woman, having a total hip arthroplasty, developed refractory nociceptive-neuropathic pain located at the ventral and dorsal aspects of the left hip. Radiographs showed a mandarine-sized intrapelvic mass of bone cement adhering to the roof of the acetabular cup. Further surgery had been declined by the surgeon and by the patient. An 18-gauge Portex intrathecal catheter was inserted, and an intrathecal infusion of 4.75 mg/mL bupivacaine and 0.015 mg/mL buprenorphine was started from a portable Pharmacia-Deltec (St. Paul, Minnesota) pump. The mean daily doses during the treatment period (more than 6 years up to now) were 37 mg for bupivacaine and 0.114 mg for buprenorphine. The intrathecal treatment gave the patient 85-100% pain relief. The patient could transport herself in a wheelchair, was able to perform her own hygiene, receive visits, read, watch television, and also shop and visit restaurants. There has been no need to replace the intrathecal catheter. Intrathecal infusion of opioid/bupivacaine can provide satisfactory long-term analgesia in patients with refractory pain from the hip joint.
Working memory, long-term memory, and medial temporal lobe function
Jeneson, Annette; Squire, Larry R.
2012-01-01
Early studies of memory-impaired patients with medial temporal lobe (MTL) damage led to the view that the hippocampus and related MTL structures are involved in the formation of long-term memory and that immediate memory and working memory are independent of these structures. This traditional idea has recently been revisited. Impaired performance in patients with MTL lesions on tasks with short retention intervals, or no retention interval, and neuroimaging findings with similar tasks have been interpreted to mean that the MTL is sometimes needed for working memory and possibly even for visual perception itself. We present a reappraisal of this interpretation. Our main conclusion is that, if the material to be learned exceeds working memory capacity, if the material is difficult to rehearse, or if attention is diverted, performance depends on long-term memory even when the retention interval is brief. This fundamental notion is better captured by the terms subspan memory and supraspan memory than by the terms short-term memory and long-term memory. We propose methods for determining when performance on short-delay tasks must depend on long-term (supraspan) memory and suggest that MTL lesions impair performance only when immediate memory and working memory are insufficient to support performance. In neuroimaging studies, MTL activity during encoding is influenced by the memory load and correlates positively with long-term retention of the material that was presented. The most parsimonious and consistent interpretation of all the data is that subspan memoranda are supported by immediate memory and working memory and are independent of the MTL. PMID:22180053
Hair analysis for long-term monitoring of buprenorphine intake in opiate withdrawal.
Pirro, Valentina; Fusari, Ivana; Di Corcia, Daniele; Gerace, Enrico; De Vivo, Enrico; Salomone, Alberto; Vincenti, Marco
2014-12-01
Buprenorphine (BUP) is a psychoactive pharmaceutical drug largely used to treat opiate addiction. Short-term therapeutic monitoring is supported by toxicological analysis of blood and urine samples, whereas long-term monitoring by means of hair analysis is rarely used. Aim of this work was to develop and validate a highly sensitive ultrahigh-performance liquid chromatography tandem mass spectrometry method to detect BUP and norbuprenorphine (NBUP) in head hair. Interindividual correlation between oral dosage of BUP and head hair concentration was investigated. Furthermore, an intra-individual study by means of segmental analysis was performed on subjects with variable maintenance dosage. Hair samples from a population of 79 patients in treatment for opiate addiction were analyzed. The validated ultrahigh-performance liquid chromatography tandem mass spectrometry protocol allowed to obtain limits of detection and quantification at 0.6 and 2.2 pg/mg for BUP and 5.0 and 17 pg/mg for NBUP, respectively. Validation criteria were satisfied, assuring selective analyte identification, high detection capability, and precise and accurate quantification. Significant positive correlation was found between constant oral BUP dosage (1-32 mg/d) and the summed up head hair concentrations of BUP and NBUP. Nevertheless, substantial interindividual variability limits the chance to predict the oral dosage taken by each subject from the measured concentrations in head hair. In contrast, strong correlation was observed in the results of intra-individual segmental analysis, which proved reliable to detect oral dosage variations during therapy. Remarkably, all hair samples yielded BUP concentrations higher than 10 pg/mg, even when the lowest dosage was administered. Thus, these results support the selection of 10 pg/mg as a cutoff value.
Study of advanced techniques for determining the long term performance of components
NASA Technical Reports Server (NTRS)
1973-01-01
The application of existing and new technology to the problem of determining the long-term performance capability of liquid rocket propulsion feed systems is discussed. The long term performance of metal to metal valve seats in a liquid propellant fuel system is stressed. The approaches taken in conducting the analysis are: (1) advancing the technology of characterizing components through the development of new or more sensitive techniques and (2) improving the understanding of the physical of degradation.
The Archive Solution for Distributed Workflow Management Agents of the CMS Experiment at LHC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuznetsov, Valentin; Fischer, Nils Leif; Guo, Yuyi
The CMS experiment at the CERN LHC developed the Workflow Management Archive system to persistently store unstructured framework job report documents produced by distributed workflow management agents. In this paper we present its architecture, implementation, deployment, and integration with the CMS and CERN computing infrastructures, such as central HDFS and Hadoop Spark cluster. The system leverages modern technologies such as a document oriented database and the Hadoop eco-system to provide the necessary flexibility to reliably process, store, and aggregatemore » $$\\mathcal{O}$$(1M) documents on a daily basis. We describe the data transformation, the short and long term storage layers, the query language, along with the aggregation pipeline developed to visualize various performance metrics to assist CMS data operators in assessing the performance of the CMS computing system.« less
The Archive Solution for Distributed Workflow Management Agents of the CMS Experiment at LHC
Kuznetsov, Valentin; Fischer, Nils Leif; Guo, Yuyi
2018-03-19
The CMS experiment at the CERN LHC developed the Workflow Management Archive system to persistently store unstructured framework job report documents produced by distributed workflow management agents. In this paper we present its architecture, implementation, deployment, and integration with the CMS and CERN computing infrastructures, such as central HDFS and Hadoop Spark cluster. The system leverages modern technologies such as a document oriented database and the Hadoop eco-system to provide the necessary flexibility to reliably process, store, and aggregatemore » $$\\mathcal{O}$$(1M) documents on a daily basis. We describe the data transformation, the short and long term storage layers, the query language, along with the aggregation pipeline developed to visualize various performance metrics to assist CMS data operators in assessing the performance of the CMS computing system.« less
Advanced technology lightweight fuel cell program
NASA Technical Reports Server (NTRS)
Martin, R. E.
1981-01-01
The potential of the alkaline electrolyte fuel cell as the power source in a multi hundred kilowatt orbital energy storage system was studied. The total system weight of an electrolysis cell energy storage system was determined. The tests demonstrated: (1) the performance stability of a platinum on carbon anode catalyst configuration after 5000 hours of testing has no loss in performance; (2) capability of the alkaline fuel cell to operate to a cyclical load profile; (3) suitability of a lightweight graphite electrolyte reservoir plate for use in the alkaline fuel cell; (4) long life potential of a hybrid polysulfone cell edge frame construction; and (5) long term stability of a fiber reinforced potassium titanate matrix structure. The power section tested operates with passive water removal eliminating the requirement for a dynamic hydrogen pump water separator thereby allowing a powerplant design with reduced weight, lower parasite power, and a potential for high reliability and extended endurance. It is concluded that two perovskites are unsuitable for use as a catalyst or as a catalyst support at the cathode of an alkaline fuel cell.
Long-term quality assurance of [(18)F]-fluorodeoxyglucose (FDG) manufacturing.
Gaspar, Ludovit; Reich, Michal; Kassai, Zoltan; Macasek, Fedor; Rodrigo, Luis; Kruzliak, Peter; Kovac, Peter
2016-01-01
Nine years of experience with 2286 commercial synthesis allowed us to deliver comprehensive information on the quality of (18)F-FDG production. Semi-automated FDG production line using Cyclone 18/9 machine (IBA Belgium), TRACERLab MXFDG synthesiser (GE Health, USA) using alkalic hydrolysis, grade "A" isolator with dispensing robotic unit (Tema Sinergie, Italy), and automatic control system under GAMP5 (minus2, Slovakia) was assessed by TQM tools as highly reliable aseptic production line, fully compliant with Good Manufacturing Practice and just-in-time delivery of FDG radiopharmaceutical. Fluoride-18 is received in steady yield and of very high radioactive purity. Synthesis yields exhibited high variance connected probably with quality of disposable cassettes and chemicals sets. Most performance non-conformities within the manufacturing cycle occur at mechanical nodes of dispensing unit. The long-term monitoring of 2286 commercial synthesis indicated high reliability of automatic synthesizers. Shewhart chart and ANOVA analysis showed that minor non-compliances occurred were mostly caused by the declinations of less experienced staff from standard operation procedures, and also by quality of automatic cassettes. Only 15 syntheses were found unfinished and in 4 cases the product was out-of-specification of European Pharmacopoeia. Most vulnerable step of manufacturing was dispensing and filling in grade "A" isolator. Its cleanliness and sterility was fully controlled under the investigated period by applying hydrogen peroxide vapours (VHP). Our experience with quality assurance in the production of [(18)F]-fluorodeoxyglucose (FDG) at production facility of BIONT based on TRACERlab MXFDG production module can be used for bench-marking of the emerging manufacturing and automated manufacturing systems.
Long-term quality assurance of [18F]-fluorodeoxyglucose (FDG) manufacturing
Gaspar, Ludovit; Reich, Michal; Kassai, Zoltan; Macasek, Fedor; Rodrigo, Luis; Kruzliak, Peter; Kovac, Peter
2016-01-01
Nine years of experience with 2286 commercial synthesis allowed us to deliver comprehensive information on the quality of 18F-FDG production. Semi-automated FDG production line using Cyclone 18/9 machine (IBA Belgium), TRACERLab MXFDG synthesiser (GE Health, USA) using alkalic hydrolysis, grade “A” isolator with dispensing robotic unit (Tema Sinergie, Italy), and automatic control system under GAMP5 (minus2, Slovakia) was assessed by TQM tools as highly reliable aseptic production line, fully compliant with Good Manufacturing Practice and just-in-time delivery of FDG radiopharmaceutical. Fluoride-18 is received in steady yield and of very high radioactive purity. Synthesis yields exhibited high variance connected probably with quality of disposable cassettes and chemicals sets. Most performance non-conformities within the manufacturing cycle occur at mechanical nodes of dispensing unit. The long-term monitoring of 2286 commercial synthesis indicated high reliability of automatic synthesizers. Shewhart chart and ANOVA analysis showed that minor non-compliances occurred were mostly caused by the declinations of less experienced staff from standard operation procedures, and also by quality of automatic cassettes. Only 15 syntheses were found unfinished and in 4 cases the product was out-of-specification of European Pharmacopoeia. Most vulnerable step of manufacturing was dispensing and filling in grade “A” isolator. Its cleanliness and sterility was fully controlled under the investigated period by applying hydrogen peroxide vapours (VHP). Our experience with quality assurance in the production of [18F]-fluorodeoxyglucose (FDG) at production facility of BIONT based on TRACERlab MXFDG production module can be used for bench-marking of the emerging manufacturing and automated manufacturing systems. PMID:27508102
Highly reliable high-power AlGaAs/GaAs 808 nm diode laser bars
NASA Astrophysics Data System (ADS)
Hülsewede, R.; Schulze, H.; Sebastian, J.; Schröder, D.; Meusel, J.; Hennig, P.
2007-02-01
There are strong demands at the market to increase power and reliability for 808 nm diode laser bars. Responding to this JENOPTIK Diode Lab GmbH developed high performance 808 nm diode laser bars in the AlGaAs/GaAs material system with special emphasis to high power operation and long term stability. Optimization of the epitaxy structure and improvements in the diode laser bar design results in very high slope efficiency of >1.2 W/A, low threshold current and small beam divergence in slow axis direction. Including low serial resistance the overall wall plug efficiency is up to 65% for our 20%, 30% and 50% filling factor 10 mm diode laser bars. With the JENOPTIK Diode Lab cleaving and coating technique the maximum output power is 205 W in CW operation and 377 W in QCW operation (200 μs, 2% duty cycle) for bars with 50% filling factor. These bars mounted on micro channel cooled package are showing a very high reliability of >15.000 h. Mounted on conductive cooled package high power operation at 100 W is demonstrated for more than 5000h.
Yekang Ko; Jun-Hak Lee; E. Gregory McPherson; Lara A. Roman
2015-01-01
Long-term survival and growth of urban forests are critical to achieve the targeted benefits of urban tree planting programs, such as building energy savings from tree shade. However, little is known about how trees perform in the long-term, especially in residential areas. Given this gap in the literature, we monitored 22-years of post-planting survival, growth, and...
Initiation process of earthquakes and its implications for seismic hazard reduction strategy.
Kanamori, H
1996-01-01
For the average citizen and the public, "earthquake prediction" means "short-term prediction," a prediction of a specific earthquake on a relatively short time scale. Such prediction must specify the time, place, and magnitude of the earthquake in question with sufficiently high reliability. For this type of prediction, one must rely on some short-term precursors. Examinations of strain changes just before large earthquakes suggest that consistent detection of such precursory strain changes cannot be expected. Other precursory phenomena such as foreshocks and nonseismological anomalies do not occur consistently either. Thus, reliable short-term prediction would be very difficult. Although short-term predictions with large uncertainties could be useful for some areas if their social and economic environments can tolerate false alarms, such predictions would be impractical for most modern industrialized cities. A strategy for effective seismic hazard reduction is to take full advantage of the recent technical advancements in seismology, computers, and communication. In highly industrialized communities, rapid earthquake information is critically important for emergency services agencies, utilities, communications, financial companies, and media to make quick reports and damage estimates and to determine where emergency response is most needed. Long-term forecast, or prognosis, of earthquakes is important for development of realistic building codes, retrofitting existing structures, and land-use planning, but the distinction between short-term and long-term predictions needs to be clearly communicated to the public to avoid misunderstanding. Images Fig. 8 PMID:11607657
Developing a Robust Strategy for Implementing a Water Resources Master Plan in Lima, Peru
NASA Astrophysics Data System (ADS)
Kalra, N.; Groves, D.; Bonzanigo, L.; Molina-Perez, E.
2015-12-01
Lima, the capital of Peru, faces significant water stress. It is the fifth largest metropolitan area in Latin America, and the second largest desert city in the world. The city has developed a Master Plan of major investment projects to improve water reliability until 2040. Yet key questions remain. Is the Master Plan sufficient for ensuring reliability in the face of deeply uncertain future climate change and demand? How do uncertain budget and project feasibility conditions shape Lima's options? How should the investments in the plan be prioritized, and can some be delayed? Lima is not alone in facing these planning challenges. Governments invest billions of dollars annually in long-term projects. Yet deep uncertainties pose formidable challenges to making near-term decisions that make long-term sense. The World Bank has spearheaded a community of practice on methods for Decision Making Under Deep Uncertainty (DMU). This pilot project in Peru is the first in-depth application of DMU techniques to water supply planning in a developing country. It builds on prior analysis done in New York, California, and for the Colorado River, yet shows how these methods can be applied in regions which do not have as advanced data or tools available. The project combines three methods in particular -- Robust Decision Making, Decision Scaling, and Adaptive Pathways -- to help Lima implement its Master Plan in a way that is robust, no-regret, and adaptive. It was done in close partnership with SEDAPAL, the water utility company in Lima, and in coordination with other national WRM and meteorological agencies. This talk will: Present the planning challenges Lima and other cities face, including climate change Describe DMU methodologies and how they were applied in collaboration with SEDAPAL Summarize recommendations for achieving long-term water reliability in Lima Suggest how these methodologies can benefit other investment projects in developing countries.
DOT National Transportation Integrated Search
2016-08-01
This document is a technical summary of the Federal Highway Administration Long-Term Pavement Performance Program report, Pavement Performance Measures and Forecasting and the Effects of Maintenance and Rehabilitation Strategy on Treatment Effectiven...
A Low-Cost, In Situ Resistivity and Temperature Monitoring System
We present a low-cost, reliable method for long-term in situ autonomous monitoring of subsurface resistivity and temperature in a shallow, moderately heterogeneous subsurface. Probes, to be left in situ, were constructed at relatively low cost with close electrode spacing. Once i...
A Critique of the Research on Learning Styles.
ERIC Educational Resources Information Center
Curry, Lynn
1990-01-01
Learning styles advocates claim long-term improvements in four aspects of teaching and learning: curriculum design, instructional methods, assessment, and student guidance. The application of learning style theory encompasses three pervasive problems: confusion in definitions, weakness in measurement reliability and validity, and identification of…
Test Hardware Design for Flightlike Operation of Advanced Stirling Convertors (ASC-E3)
NASA Technical Reports Server (NTRS)
Oriti, Salvatore M.
2012-01-01
NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, the Thermal Energy Conversion branch at GRC has been conducting extended operation of a multitude of free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) simultaneously on multiple units to build a life and reliability database. The test hardware for operation of these convertors was designed to permit in-air investigative testing, such as performance mapping over a range of environmental conditions. With this, there was no requirement to accurately emulate the flight hardware. For the upcoming ASC-E3 units, the decision has been made to assemble the convertors into a flight-like configuration. This means the convertors will be arranged in the dual-opposed configuration in a housing that represents the fit, form, and thermal function of the ASRG. The goal of this effort is to enable system level tests that could not be performed with the traditional test hardware at GRC. This offers the opportunity to perform these system-level tests much earlier in the ASRG flight development, as they would normally not be performed until fabrication of the qualification unit. This paper discusses the requirements, process, and results of this flight-like hardware design activity.
Test Hardware Design for Flight-Like Operation of Advanced Stirling Convertors
NASA Technical Reports Server (NTRS)
Oriti, Salvatore M.
2012-01-01
NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, the Thermal Energy Conversion branch at GRC has been conducting extended operation of a multitude of free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) simultaneously on multiple units to build a life and reliability database. The test hardware for operation of these convertors was designed to permit in-air investigative testing, such as performance mapping over a range of environmental conditions. With this, there was no requirement to accurately emulate the flight hardware. For the upcoming ASC-E3 units, the decision has been made to assemble the convertors into a flight-like configuration. This means the convertors will be arranged in the dual-opposed configuration in a housing that represents the fit, form, and thermal function of the ASRG. The goal of this effort is to enable system level tests that could not be performed with the traditional test hardware at GRC. This offers the opportunity to perform these system-level tests much earlier in the ASRG flight development, as they would normally not be performed until fabrication of the qualification unit. This paper discusses the requirements, process, and results of this flight-like hardware design activity.
Stumpe, Katrin D. M.; Grimm, Felix; Deplazes, Peter; Huber, Sabine; Bertogg, Kaja; Fischer, Dorothee R.; Müllhaupt, Beat
2015-01-01
Background/Aims Benzimidazoles are efficacious for treating non-resectable alveolar echinococcosis (AE), but their long-term parasitocidal (curative) effect is disputed. In this study, we prospectively analyzed the potential parasitocidal effect of benzimidazoles and whether normalization of FDG-PET/CT scans and anti-Emll/3-10-antibody levels could act as reliable "in vivo" parameters of AE-inactivation permitting to abrogate chemotherapy with a low risk for AE-recurrence. Method This prospective study included 34 patients with non-resectable AE subdivided into group A (n = 11), followed-up after diagnosis and begin of chemotherapy at months 6, 12 and 24, and group B (n = 23) with a medium duration of chemotherapy of 10 (range 2–25) years. All patients were assessed by FDG-PET/CT examinations and anti-EmII/3-10 serology. Chemotherapy was abrogated in patients with normalization of FDG-PET/CT and serum anti-EmII/3-10 levels. These patients were closely followed-up for AE recurrence. Endpoint (parasitocidal efficacy) was defined by the absence of AE-recurrence >24 months after stopping treatment. Results Normalization of FDG-PET/CT scan and anti-EmII/3-10 levels occurred in 11 of 34 patients (32%). After abrogation of chemotherapy in these 11 patients, there was no evidence of AE-recurrence within a median of 70.5 (range 16–82) months. However, the patients’ immunocompetence appears pivotal for the described long-term parasitocidal effect of benzimidazoles. Conclusions The combination of negative FDG-PET/CT-scans and anti-EmII/3-10 antibody levels seem to be reliable parameters for assessing in vivo AE-larval inactivity after long-term benzimidazole chemotherapy. Trial Registration clinicaltrials.gov: NCT00658294 PMID:26389799
A Robust, Gravity-Insensitive, High-Temperature Condenser for Water Recovery
NASA Technical Reports Server (NTRS)
Chen, Weibo; Conboy, Thomas; Ewert, Michael
2016-01-01
Regenerative life support systems are vital for NASA's future long-duration human space exploration missions. A Heat Melt Compactor (HMC) system is being developed by NASA to dry and compress trash generated during space missions. The resulting water vapor is recovered and separated from the process gas flow by a gravity-insensitive condenser. Creare is developing a high-temperature condenser for this application. The entire condenser is constructed from metals that have excellent resistance to chemical attack from contaminants and is suitable for high-temperature operation. The metal construction and design configuration also offer greatest flexibility for potential coating and regeneration processes to reduce biofilm growth and thus enhancing the reliability of the condenser. The proposed condenser builds on the gravity-insensitive phase separator technology Creare developed for aircraft and spacecraft applications. This paper will first discuss the design requirements for the condenser in an HMC system that will be demonstrated on the International Space Station (ISS). Then, it will present the overall design of the condenser and the preliminary thermal test results of a subscale condenser. Finally, this paper will discuss the predicted performance of the full-size condenser and the development plan to mature the technology and enhance its long-term reliability for a flight system.
Long-Term Pavement Performance Bind Online [Product Brief
DOT National Transportation Integrated Search
2017-02-23
This Product Brief introduces the reader to the Long-Term Pavement Performance Bind (LTPPBind) Online Web-based tool for selecting asphalt binder performance grades (PGs).(1) It explains what the tool is, who can benefit from its use, what its main f...
Ojanen, Sami P; Nieminen, Marko; Meyke, Evgeniy; Pöyry, Juha; Hanski, Ilkka
2013-10-01
Long-term observational studies conducted at large (regional) spatial scales contribute to better understanding of landscape effects on population and evolutionary dynamics, including the conditions that affect long-term viability of species, but large-scale studies are expensive and logistically challenging to keep running for a long time. Here, we describe the long-term metapopulation study of the Glanville fritillary butterfly (Melitaea cinxia) that has been conducted since 1991 in a large network of 4000 habitat patches (dry meadows) within a study area of 50 by 70 km in the Åland Islands in Finland. We explain how the landscape structure has been described, including definition, delimitation, and mapping of the habitat patches; methods of field survey, including the logistics, cost, and reliability of the survey; and data management using the EarthCape biodiversity platform. We describe the long-term metapopulation dynamics of the Glanville fritillary based on the survey. There has been no long-term change in the overall size of the metapopulation, but the level of spatial synchrony and hence the amplitude of fluctuations in year-to-year metapopulation dynamics have increased over the years, possibly due to increasing frequency of exceptional weather conditions. We discuss the added value of large-scale and long-term population studies, but also emphasize the need to integrate more targeted experimental studies in the context of long-term observational studies. For instance, in the case of the Glanville fritillary project, the long-term study has produced an opportunity to sample individuals for experiments from local populations with a known demographic history. These studies have demonstrated striking differences in dispersal rate and other life-history traits of individuals from newly established local populations (the offspring of colonizers) versus individuals from old, established local populations. The long-term observational study has stimulated the development of metapopulation models and provided an opportunity to test model predictions. This combination of empirical studies and modeling has facilitated the study of key phenomena in spatial dynamics, such as extinction threshold and extinction debt.
Ojanen, Sami P; Nieminen, Marko; Meyke, Evgeniy; Pöyry, Juha; Hanski, Ilkka
2013-01-01
Long-term observational studies conducted at large (regional) spatial scales contribute to better understanding of landscape effects on population and evolutionary dynamics, including the conditions that affect long-term viability of species, but large-scale studies are expensive and logistically challenging to keep running for a long time. Here, we describe the long-term metapopulation study of the Glanville fritillary butterfly (Melitaea cinxia) that has been conducted since 1991 in a large network of 4000 habitat patches (dry meadows) within a study area of 50 by 70 km in the Åland Islands in Finland. We explain how the landscape structure has been described, including definition, delimitation, and mapping of the habitat patches; methods of field survey, including the logistics, cost, and reliability of the survey; and data management using the EarthCape biodiversity platform. We describe the long-term metapopulation dynamics of the Glanville fritillary based on the survey. There has been no long-term change in the overall size of the metapopulation, but the level of spatial synchrony and hence the amplitude of fluctuations in year-to-year metapopulation dynamics have increased over the years, possibly due to increasing frequency of exceptional weather conditions. We discuss the added value of large-scale and long-term population studies, but also emphasize the need to integrate more targeted experimental studies in the context of long-term observational studies. For instance, in the case of the Glanville fritillary project, the long-term study has produced an opportunity to sample individuals for experiments from local populations with a known demographic history. These studies have demonstrated striking differences in dispersal rate and other life-history traits of individuals from newly established local populations (the offspring of colonizers) versus individuals from old, established local populations. The long-term observational study has stimulated the development of metapopulation models and provided an opportunity to test model predictions. This combination of empirical studies and modeling has facilitated the study of key phenomena in spatial dynamics, such as extinction threshold and extinction debt. PMID:24198935
Akdemir, Hülya; Suzerer, Veysel; Tilkat, Engin; Onay, Ahmet; Çiftçi, Yelda Ozden
2016-12-01
Determination of genetic stability of in vitro-grown plantlets is needed for safe and large-scale production of mature trees. In this study, genetic variation of long-term micropropagated mature pistachio developed through direct shoot bud regeneration using apical buds (protocol A) and in vitro-derived leaves (protocol B) was assessed via DNA-based molecular markers. Randomly amplified polymorphic DNA (RAPD), inter-simple sequence repeat (ISSR), and amplified fragment length polymorphism (AFLP) were employed, and the obtained PIC values from RAPD (0.226), ISSR (0.220), and AFLP (0.241) showed that micropropagation of pistachio for different periods of time resulted in "reasonable polymorphism" among donor plant and its 18 clones. Mantel's test showed a consistence polymorphism level between marker systems based on similarity matrices. In conclusion, this is the first study on occurrence of genetic variability in long-term micropropagated mature pistachio plantlets. The obtained results clearly indicated that different marker approaches used in this study are reliable for assessing tissue culture-induced variations in long-term cultured pistachio plantlets.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LataPhD, Vasiliy; Coates, Cameron W
2010-01-01
Through a cooperative effort between the US Department of Energy and the Russian Federation (RF) Ministry of Defense (MOD) a Personnel Reliability Program (PRP) for the nuclear handlers within the RF MOD is at the stage of implementation. Sustaining the program is of major significance for long term success. This paper will discuss the elements of the RF PRP and the equipment needs for implementation. Program requirements, documentation needs, training, and assurances of appropriate equipment use will be addressed.
Falcone, Brian; Wada, Atsushi; Parasuraman, Raja
2018-01-01
Transcranial direct current stimulation (tDCS) has been shown to enhance cognitive performance on a variety of tasks. It is hypothesized that tDCS enhances performance by affecting task related cortical excitability changes in networks underlying or connected to the site of stimulation facilitating long term potentiation. However, many recent studies have called into question the reliability and efficacy of tDCS to induce modulatory changes in brain activity. In this study, our goal is to investigate the individual differences in tDCS induced modulatory effects on brain activity related to the degree of enhancement in performance, providing insight into this lack of reliability. In accomplishing this goal, we used functional magnetic resonance imaging (fMRI) concurrently with tDCS stimulation (1 mA, 30 minutes duration) using a visual search task simulating real world conditions. The experiment consisted of three fMRI sessions: pre-training (no performance feedback), training (performance feedback which included response accuracy and target location and either real tDCS or sham stimulation given), and post-training (no performance feedback). The right posterior parietal cortex was selected as the site of anodal tDCS based on its known role in visual search and spatial attention processing. Our results identified a region in the right precentral gyrus, known to be involved with visual spatial attention and orienting, that showed tDCS induced task related changes in cortical excitability that were associated with individual differences in improved performance. This same region showed greater activity during the training session for target feedback of incorrect (target-error feedback) over correct trials for the tDCS stim over sham group indicating greater attention to target features during training feedback when trials were incorrect. These results give important insight into the nature of neural excitability induced by tDCS as it relates to variability in individual differences in improved performance shedding some light the apparent lack of reliability found in tDCS research. PMID:29782510
The precision and torque production of common hip adductor squeeze tests used in elite football.
Light, N; Thorborg, K
2016-11-01
Decreased hip adductor strength is a known risk factor for groin injury in footballers, with clinicians testing adductor strength in various positions and using different protocols. Understanding how reliable and how much torque different adductor squeeze tests produce will facilitate choosing the most appropriate method for future testing. In this study, the reliability and torque production of three common adductor squeeze tests were investigated. Test-retest reliability and cross-sectional comparison. Twenty elite level footballers (16-33 years) without previous or current groin pain were recruited. Relative and absolute test-retest reliability, and torque production of three adductor squeeze tests (long-lever in abduction, short-lever in adduction and short-lever in abduction/external rotation) were investigated. Each participant performed a series of isometric strength tests measured by hand-held dynamometry in each position, on two test days separated by two weeks. No systematic variation was seen for any of the tests when using the mean of three measures (ICC=0.84-0.97, MDC%=6.6-19.5). The smallest variation was observed when taking the mean of three repetitions in the long-lever position (ICC=0.97, MDC%=6.6). The long-lever test also yielded the highest mean torque values, which were 69% and 11% higher than the short-lever in adduction test and short-lever in abduction/external rotation test respectively (p<0.001). All three tests described in this study are reliable methods of measuring adductor squeeze strength. However, the test performed in the long-lever position seems the most promising as it displays high test-retest precision and the highest adductor torque production. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
High Temperature Steam Electrolysis: Demonstration of Improved Long-Term Performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. E. O'Brien; X. Zhang; R. C. O'Brien
2011-11-01
Long-term performance is an ongoing issue for hydrogen production based on high-temperature steam electrolysis (HTSE). For commercial deployment, solid-oxide electrolysis stacks must achieve high performance with long-term degradation rates of {approx}0.5%/1000 hours or lower. Significant progress has been achieved toward this goal over the past few years. This paper will provide details of progress achieved under the Idaho National Laboratory high temperature electrolysis research program. Recent long-term stack tests have achieved high initial performance with degradation rates less than 5%/khr. These tests utilize internally manifolded stacks with electrode-supported cells. The cell material sets are optimized for the electrolysis mode ofmore » operation. Details of the cells and stacks will be provided along with details of the test apparatus, procedures, and results.« less
Roach, Kathryn E; Tappen, Ruth M; Kirk-Sanchez, Neva; Williams, Christine L; Loewenstein, David
2011-01-01
To determine whether an activity specific exercise program could improve ability to perform basic mobility activities in long-term care residents with Alzheimer disease (AD). Randomized, controlled, single-blinded clinical trial. Residents of 7 long-term care facilities. Eighty-two long-term care residents with mild to severe AD. An activity specific exercise program was compared to a walking program and to an attention control. Ability to perform bed mobility and transfers was assessed using the subscales of the Acute Care Index of Function; functional mobility was measured using the 6-Minute Walk test. Subjects receiving the activity specific exercise program improved in ability to perform transfers, whereas subjects in the other 2 groups declined.
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, Santhisagar; Burgess, Diane J; Tomazos, Ioannis; Jain, Faquir C; Papadimitrakopoulos, Fotios
2010-01-01
Devices for continuous glucose monitoring (CGM) are currently a major focus of research in the area of diabetes management. It is envisioned that such devices will have the ability to alert a diabetes patient (or the parent or medical care giver of a diabetes patient) of impending hypoglycemic/hyperglycemic events and thereby enable the patient to avoid extreme hypoglycemic/hyperglycemic excursions as well as minimize deviations outside the normal glucose range, thus preventing both life-threatening events and the debilitating complications associated with diabetes. It is anticipated that CGM devices will utilize constant feedback of analytical information from a glucose sensor to activate an insulin delivery pump, thereby ultimately realizing the concept of an artificial pancreas. Depending on whether the CGM device penetrates/breaks the skin and/or the sample is measured extracorporeally, these devices can be categorized as totally invasive, minimally invasive, and noninvasive. In addition, CGM devices are further classified according to the transduction mechanisms used for glucose sensing (i.e., electrochemical, optical, and piezoelectric). However, at present, most of these technologies are plagued by a variety of issues that affect their accuracy and long-term performance. This article presents a critical comparison of existing CGM technologies, highlighting critical issues of device accuracy, foreign body response, calibration, and miniaturization. An outlook on future developments with an emphasis on long-term reliability and performance is also presented. PMID:21129353
Early age damage quantification of actively restrained concrete using inverse analysis
NASA Astrophysics Data System (ADS)
Albanna, Ali
Early-age cracking can be a significant problem in concrete pavements, floors, and bridge decks. Cracking occurs when the volumetric changes associated with drying, hydration, and temperature reduction are prevented. Good knowledge about the characteristics of early age concrete is necessary to achieve reliable crack control. Volumetric changes due to shrinkage depend on the type of concrete and its components. It has been found that light weight aggregates can work as internal reservoir to supply the concrete matrix with water that is needed during the early age; this process is called internal curing. Also fibers can give more ductility to the concrete and produce less shrinkage. There is a need to better understand the effects of early age uniaxial restraint on long term concrete mechanical performance. In this study, two types of concrete were studied (high performance fiber reinforced concrete and ordinary concrete) under actively restrained loading conditions to assess the effect on the long term fracture toughness and energy. Single edge notched specimens having dimensions of 250 mm x 150 mm x 75 mm and a notch to depth ratio of 0.33 were caste and used in both direct tension and three point bending. The direct tension tests were carried out on a direct tension loading frame constructed in house that was supplied with two mechanical jacks and load cell.
Maeda, Taku; Kimura, Chu; Murao, Naoki; Takahashi, Kikuko
2015-09-01
The reused skin-graft technique can be used to treat chronic gluteal hidradenitis suppurativa, but long-term outcomes and the reliability of the technique have not been reported. In a retrospective review of 18 men with chronic gluteal hidradenitis suppurativa (age range, 18-68 years) treated with a reused skin graft between June 2004 and March 2012, we evaluated disease severity (Hurley classification system), skin-graft thickness, the need for an additional normal skin graft, histological findings and recurrence rate at the surgical site. The mean duration of follow-up was 61.3 months (range, 17-113 months). Five cases were classified into severity group I, 12 cases into severity group II and one case into severity group III. The range of skin-graft thicknesses was 0.013-0.020 inches. An additional donor site was unnecessary in 10 cases (three cases in group I (60%) and seven cases in group II (58.3%)). Histological examination indicated that a buried epidermal cyst could cause chronic gluteal hidradenitis suppurativa recurrence, although none of the patients experienced recurrence at the surgical site during follow-up. The reused skin-graft technique is reliable for chronic gluteal hidradenitis suppurativa resection, and it shows promising long-term outcomes. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Long-term stability of the Wechsler Intelligence Scale for Children--Fourth Edition.
Watkins, Marley W; Smith, Lourdes G
2013-06-01
Long-term stability of the Wechsler Intelligence Scale for Children-Fourth Edition (WISC-IV; Wechsler, 2003) was investigated with a sample of 344 students from 2 school districts twice evaluated for special education eligibility at an average interval of 2.84 years. Test-retest reliability coefficients for the Verbal Comprehension Index (VCI), Perceptual Reasoning Index (PRI), Working Memory Index (WMI), Processing Speed Index (PSI), and the Full Scale IQ (FSIQ) were .72, .76, .66, .65, and .82, respectively. As predicted, the test-retest reliability coefficients for the subtests (Mdn = .56) were generally lower than the index scores (Mdn = .69) and the FSIQ (.82). On average, subtest scores did not differ by more than 1 point, and index scores did not differ by more than 2 points across the test-retest interval. However, 25% of the students earned FSIQ scores that differed by 10 or more points, and 29%, 39%, 37%, and 44% of the students earned VCI, PRI, WMI, and PSI scores, respectively, that varied by 10 or more points. Given this variability, it cannot be assumed that WISC-IV scores will be consistent across long test-retest intervals for individual students. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Long-term lunar stations: Some ecological considerations
NASA Technical Reports Server (NTRS)
Maguire, Bassett, Jr.; Scott, Kelly W.
1992-01-01
A major factor for long-term success of a lunar station is the ability to keep an agroecosystem functioning at a desirable, stable steady-state with ecological stability and reliability. Design for a long-lived extraterrestrial manned station must take into account interactions among its subsystems to insure that overall functionality is enhanced (or at least not compromised). Physical isolation of feed production, human living areas, recycling, and other systems may be straightforward, however, microbiological isolation will be very difficult. While it is possible to eliminate plant-associated microbiological communities by growing the plants asepticallly, it is not practical to keep plants germ-free on a large scale if humans are working with them. Ecological theory strongly suggests that some kinds of communities or organisms effectively increase the stability of ecosystems and will protect the plants from potential pathogens. A carefully designed and maintained (lunar-derived) soil can provide a variety of habitats for effective microbial buffers while adding structure to the agroecosystem. A soil can also increase ecosystem reliability through buffering otherwise large element and compound fluctuations (of nutrients, wastes, etc.) as well as buffering temperature level and atmosphere composition. We are doing experiments in ecological dynamics and attempting to extend the relevant theories.
ERIC Educational Resources Information Center
Ayala, Erika
2016-01-01
The purpose of this sequential explanatory embedded mixed methods study was to: (a) investigate and describe the academic performance of eighth grade students in the Falcon School District (FSD) who were designated as Long Term English Learners (LTELs) and participants in FSD's reading intervention program during their fourth through eighth grade…
NASA Technical Reports Server (NTRS)
Ramesham, Rajeshuni
2012-01-01
This paper provides the experimental test results of advanced CCGA packages tested in extreme temperature thermal environments. Standard optical inspection and x-ray non-destructive inspection tools were used to assess the reliability of high density CCGA packages for deep space extreme temperature missions. Ceramic column grid array (CCGA) packages have been increasing in use based on their advantages such as high interconnect density, very good thermal and electrical performances, compatibility with standard surface-mount packaging assembly processes, and so on. CCGA packages are used in space applications such as in logic and microprocessor functions, telecommunications, payload electronics, and flight avionics. As these packages tend to have less solder joint strain relief than leaded packages or more strain relief over lead-less chip carrier packages, the reliability of CCGA packages is very important for short-term and long-term deep space missions. We have employed high density CCGA 1152 and 1272 daisy chained electronic packages in this preliminary reliability study. Each package is divided into several daisy-chained sections. The physical dimensions of CCGA1152 package is 35 mm x 35 mm with a 34 x 34 array of columns with a 1 mm pitch. The dimension of the CCGA1272 package is 37.5 mm x 37.5 mm with a 36 x 36 array with a 1 mm pitch. The columns are made up of 80% Pb/20%Sn material. CCGA interconnect electronic package printed wiring polyimide boards have been assembled and inspected using non-destructive x-ray imaging techniques. The assembled CCGA boards were subjected to extreme temperature thermal atmospheric cycling to assess their reliability for future deep space missions. The resistance of daisy-chained interconnect sections were monitored continuously during thermal cycling. This paper provides the experimental test results of advanced CCGA packages tested in extreme temperature thermal environments. Standard optical inspection and x-ray non-destructive inspection tools were used to assess the reliability of high density CCGA packages for deep space extreme temperature missions. Keywords: Extreme temperatures, High density CCGA qualification, CCGA reliability, solder joint failures, optical inspection, and x-ray inspection.
DOT National Transportation Integrated Search
2005-09-01
The Long-Term Pavement Performance (LTPP) program was designed as a 20-year study of pavement performance. A major data collection effort at LTPP test sections is the collection of longitudinal profile data using inertial profilers. Three types of in...
Methods for Bacteriophage Preservation.
Łobocka, Małgorzata B; Głowacka, Aleksandra; Golec, Piotr
2018-01-01
In a view of growing interest in bacteriophages as the most abundant members of microbial communities and as antibacterial agents, reliable methods for bacteriophage long-term preservation, that warrant the access to original or mutant stocks of unchanged properties, have become of crucial importance. A storage method that retains the infectivity of any kind of bacteriophage virions, either in a cell lysate or in a purified suspension, does not exist, due to the enormous diversity of bacteriophages and hence the differentiation of their sensitivity to various storage conditions. Here, we describe a method of long-term bacteriophage preservation, which is based on freezing of freshly infected susceptible bacteria at early stages of bacteriophage development. The infected bacteria release mature bacteriophages upon melting enabling the recovery of bacteriophage virions with high efficiency. The only limitation of this method is the sensitivity of bacteriophage host to deep-freezing, and thus it can be used for the long-term preservation of the vast majority of bacteriophages.
Hajek, André; Lehnert, Thomas; Wegener, Annemarie; Riedel-Heller, Steffi G; König, Hans-Helmut
2017-08-10
It is most likely that the need for long-term care increases considerably in the next decades due to demographic shifts. Thus, we aimed at identifying the preferences for characteristics of professional long-term caregivers among old age individuals in Germany. Data were gathered from a population-based survey of the German population aged 65 and above in 2015 (n = 1006). It was important for individuals in old age that long-term caregivers were 'empathetic, kind' (99.3%), 'punctual, reliable' (98.2%), have an 'orderly appearance' (96.4%), work in a 'small team' (92.5%) and have 'enough time' (91.5%). Moreover, while most of the individuals (76.5%) reported high preferences for 'German language', the preferences were lower for 'same cultural background' (54.2%) and 'same gender' (35.7%). In multiple logistic regressions, preferences for 'same gender' were positively associated with being female [OR 8.3 (5.6-12.1)], living with partner or spouse [OR 1.4 (1.0-1.9)], and being born abroad [OR 1.8 (1.1-3.1)]. Preferences for 'German language' were positively associated with being female [OR: 1.5 (1.1-2.1)]. Preferences for 'same cultural background' were positively associated with age [OR 1.0 (1.0-1.1)], living with partner or spouse [OR 1.4 (1.0-1.9)], and East Germany [OR 1.9 (1.3-2.7)]. Preferences for 'orderly appearance', 'empathetic, kind', 'punctual, reliable' and 'small nursing team' were all not significantly associated with included independent variables, whereas preferences for 'enough time' were positively associated with being female [OR 1.9 (1.1-3.5)], living with partner or spouse [OR 1.9 (1.1-3.4)], education [Apprenticeship, full-time vocational school, OR 3.1 (1.3-7.6)], not providing care for family/friends [OR 1.9 (1.1-3.3)], and involvement in the issue of need for care [OR 1.3 (1.1-1.6)]. Our data suggest that it is important to almost every individual aged 65 and above in Germany that professional long-term caregivers are (i) empathetic, kind, and understanding, (ii) punctual and reliable, (iii) have enough time (e.g., for conversation), (iv) and have an orderly appearance. Furthermore, several factors such as gender or region were found to be associated with preferences for characteristics of caregivers. By knowing these factors, nursing services can tailor their activities to the needs of care-recipients.
Baur, Martina; Preusser, Matthias; Piribauer, Maria; Elandt, Katarzyna; Hassler, Marco; Hudec, Marcus; Dittrich, Christian; Marosi, Christine
2010-01-01
Background The aim of this retrospective study was to analyse the MGMT (06-methylguanine-DNA methyltransferase) promoter methylation status in long-term surviving (≥ 3 years) patients with glioblastoma multiforme (GBM). Methods The methylation status of the MGMT promoter was determined by bisulfite modification of the DNA and subsequent methylation-specific polymerase-chain-reaction (MSP). DNA was extracted from routinely formalin-fixed and paraffin-embedded tumour tissue samples. Results MSP yielded interpretable results in only 14 of 33 (42%) long-term surviving patients with GBM. A methylated band was seen in 3 of 14, methylated as well as unmethylated bands in 8 of 14 and an only unmethylated band in 3 of 14 patients, thus, yielding MGMT promoter methylation in 11 of 14 patients. The two groups of patients with methylated and unmethylated MGMT promoter status were too small to draw any firm statistical conclusions. Conclusions Long-term surviving patients with GBM have very frequently intratumoural MGMT promoter methylation. This phenomenon discriminates long-term survivors from a non-selected group of patients with GBM. The standardization of the MSP for the determination of the MGMT promoter methylation status seems to be necessary in order to make this methodology a more reliable one. PMID:22933901
McShane, Lesley; Greenwell, Kate; Corbett, Sally; Walker, Richard
2014-06-01
People with long-term conditions need to be signposted to high quality information and advice to understand and manage their condition. Information seeking tools combined with third sector information could help address their information needs. To describe the development and implementation of an information service for people living with long-term conditions at one NHS acute trust in the Northeast of England. An information service was trialled using bespoke information models for three long-term conditions in collaboration with third sector organisations. These guided people to relevant, timely and reliable information. Both clinician and service user questionnaires were used to evaluate satisfaction with the service. Appropriately designed information models can be used interchangeably across all services. Between 75% and 91% of users agreed that they were satisfied with various aspects of the service. Generally, users received relevant, understandable and high quality information at the right time. Nearly all health professionals (94-100%) felt the service was accessible, provided high quality information and did not significantly impact on their consultation time. The developed information service was well received by service users and health professionals. Specifically, the use of information prescriptions and menus facilitated access to information for people with long-term conditions. © 2014 The authors. Health Information and Libraries Journal © 2014 Health Libraries Group.
Cyclical Annealing Technique To Enhance Reliability of Amorphous Metal Oxide Thin Film Transistors.
Chen, Hong-Chih; Chang, Ting-Chang; Lai, Wei-Chih; Chen, Guan-Fu; Chen, Bo-Wei; Hung, Yu-Ju; Chang, Kuo-Jui; Cheng, Kai-Chung; Huang, Chen-Shuo; Chen, Kuo-Kuang; Lu, Hsueh-Hsing; Lin, Yu-Hsin
2018-02-26
This study introduces a cyclical annealing technique that enhances the reliability of amorphous indium-gallium-zinc-oxide (a-IGZO) via-type structure thin film transistors (TFTs). By utilizing this treatment, negative gate-bias illumination stress (NBIS)-induced instabilities can be effectively alleviated. The cyclical annealing provides several cooling steps, which are exothermic processes that can form stronger ionic bonds. An additional advantage is that the total annealing time is much shorter than when using conventional long-term annealing. With the use of cyclical annealing, the reliability of the a-IGZO can be effectively optimized, and the shorter process time can increase fabrication efficiency.
Evaluation of 10V Chip Polymer Tantalum Capacitors for Space Applications
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander A.
2016-01-01
Due to low ESR and safe failure mode, new technology chip polymer tantalum capacitors (CPTC) have gained popularity in the electronics design community, first in commercial applications, and now in hi-rel and space systems. The major drawbacks of these parts are high leakage currents, degradation under environmental stresses, and a relatively narrow temperature range of operating and storage conditions. Several studies have shown that a certain amount of moisture in polymer cathodes is necessary for a normal operation of the parts. This might limit applications of CPTCs in space systems and requires analysis of long-term exposure to deep vacuum conditions on their performance and reliability. High leakage currents and limited maximum operational temperature complicate accelerated testing that is necessary to assess long-term reliability and require new screening and qualification procedures for quality assurance. A better understanding of behavior of CPTCs as compared to traditional, MnO2, capacitors is necessary to develop adequate approaches for QA system for space applications. A specific of CPTCs is that different materials and processes might be used for low-voltage (10 V and less) and high-voltage (above 10 V) capacitors, so performance and degradation processes in these groups require separate analysis. In this work, that is a part of the NASA Electronic Parts and Packaging (NEPP) program, degradation of AC and DC characteristics under environmental stresses at different temperatures and voltages have been studied in nine lots of commercial and automotive grade capacitors rated to 10 V. Results of analysis of leakage currents, high temperature storage (HTS) up to 5000 hrs in vacuum and air at different temperatures, and Highly Accelerated Life Testing (HALT) in the range from 85 C to 145 C are presented. Temperature and voltage acceleration factors were calculated based on approximation of distributions of degradation rates with a general log-linear Weibull model. Mechanisms of degradation and failures, and requirements for screening and qualification testing are discussed.
Huang, Qi; Yang, Dapeng; Jiang, Li; Zhang, Huajie; Liu, Hong; Kotani, Kiyoshi
2017-01-01
Performance degradation will be caused by a variety of interfering factors for pattern recognition-based myoelectric control methods in the long term. This paper proposes an adaptive learning method with low computational cost to mitigate the effect in unsupervised adaptive learning scenarios. We presents a particle adaptive classifier (PAC), by constructing a particle adaptive learning strategy and universal incremental least square support vector classifier (LS-SVC). We compared PAC performance with incremental support vector classifier (ISVC) and non-adapting SVC (NSVC) in a long-term pattern recognition task in both unsupervised and supervised adaptive learning scenarios. Retraining time cost and recognition accuracy were compared by validating the classification performance on both simulated and realistic long-term EMG data. The classification results of realistic long-term EMG data showed that the PAC significantly decreased the performance degradation in unsupervised adaptive learning scenarios compared with NSVC (9.03% ± 2.23%, p < 0.05) and ISVC (13.38% ± 2.62%, p = 0.001), and reduced the retraining time cost compared with ISVC (2 ms per updating cycle vs. 50 ms per updating cycle). PMID:28608824
Huang, Qi; Yang, Dapeng; Jiang, Li; Zhang, Huajie; Liu, Hong; Kotani, Kiyoshi
2017-06-13
Performance degradation will be caused by a variety of interfering factors for pattern recognition-based myoelectric control methods in the long term. This paper proposes an adaptive learning method with low computational cost to mitigate the effect in unsupervised adaptive learning scenarios. We presents a particle adaptive classifier (PAC), by constructing a particle adaptive learning strategy and universal incremental least square support vector classifier (LS-SVC). We compared PAC performance with incremental support vector classifier (ISVC) and non-adapting SVC (NSVC) in a long-term pattern recognition task in both unsupervised and supervised adaptive learning scenarios. Retraining time cost and recognition accuracy were compared by validating the classification performance on both simulated and realistic long-term EMG data. The classification results of realistic long-term EMG data showed that the PAC significantly decreased the performance degradation in unsupervised adaptive learning scenarios compared with NSVC (9.03% ± 2.23%, p < 0.05) and ISVC (13.38% ± 2.62%, p = 0.001), and reduced the retraining time cost compared with ISVC (2 ms per updating cycle vs. 50 ms per updating cycle).
NASA Astrophysics Data System (ADS)
Griffith, Steven
This thesis is an interpretive analysis of experts' perspectives on the climate implications of New England's reliance on natural gas for electricity generation. Specifically, this research, conducted through interviews and literature review, examines experts' opinions on the desired role of natural gas within the regional electricity sector, alternative energy resources, and state and regional policy opportunities toward the achievement of New England's ambitious long-term greenhouse gas reduction goals. Experts expressed concern about the climate dilemma posed by a dependence on natural gas. However, interviews revealed that short-term reliability and cost considerations are paramount for many experts, and therefore a reliance on natural gas is the existing reality. To incentivize renewable generation technologies for the purposes of long-term climate stabilization, experts advocated for the expanded implementation of renewable portfolio standard, net metering, and feed-in tariff policies. More broadly, interviewees expressed the need for an array of complementary state and regional policies.
Advanced moisture modeling of polymer composites.
DOT National Transportation Integrated Search
2014-04-01
Long term moisture exposure has been shown to affect the mechanical performance of polymeric composite structures. This reduction : in mechanical performance must be considered during product design in order to ensure long term structure survival. In...
Long-term pavement performance ancillary information management system (AIMS) reference guide.
DOT National Transportation Integrated Search
2012-11-01
This document provides information on the Long-Term Pavement Performance (LTPP) program ancillary information. : Ancillary information includes data, images, reference materials, resource documents, and other information that : support and extend the...
Long-Term Pavement Performance Automated Faulting Measurement
DOT National Transportation Integrated Search
2015-02-01
This study focused on identifying transverse joint locations on jointed plain concrete pavements using an automated joint detection algorithm and computing faulting at these locations using Long-Term Pavement Performance (LTPP) Program profile data c...
Mission Reliability Estimation for Repairable Robot Teams
NASA Technical Reports Server (NTRS)
Trebi-Ollennu, Ashitey; Dolan, John; Stancliff, Stephen
2010-01-01
A mission reliability estimation method has been designed to translate mission requirements into choices of robot modules in order to configure a multi-robot team to have high reliability at minimal cost. In order to build cost-effective robot teams for long-term missions, one must be able to compare alternative design paradigms in a principled way by comparing the reliability of different robot models and robot team configurations. Core modules have been created including: a probabilistic module with reliability-cost characteristics, a method for combining the characteristics of multiple modules to determine an overall reliability-cost characteristic, and a method for the generation of legitimate module combinations based on mission specifications and the selection of the best of the resulting combinations from a cost-reliability standpoint. The developed methodology can be used to predict the probability of a mission being completed, given information about the components used to build the robots, as well as information about the mission tasks. In the research for this innovation, sample robot missions were examined and compared to the performance of robot teams with different numbers of robots and different numbers of spare components. Data that a mission designer would need was factored in, such as whether it would be better to have a spare robot versus an equivalent number of spare parts, or if mission cost can be reduced while maintaining reliability using spares. This analytical model was applied to an example robot mission, examining the cost-reliability tradeoffs among different team configurations. Particularly scrutinized were teams using either redundancy (spare robots) or repairability (spare components). Using conservative estimates of the cost-reliability relationship, results show that it is possible to significantly reduce the cost of a robotic mission by using cheaper, lower-reliability components and providing spares. This suggests that the current design paradigm of building a minimal number of highly robust robots may not be the best way to design robots for extended missions.
Understanding and quantifying foliar temperature acclimation for Earth System Models
NASA Astrophysics Data System (ADS)
Smith, N. G.; Dukes, J.
2015-12-01
Photosynthesis and respiration on land are the two largest carbon fluxes between the atmosphere and Earth's surface. The parameterization of these processes represent major uncertainties in the terrestrial component of the Earth System Models used to project future climate change. Research has shown that much of this uncertainty is due to the parameterization of the temperature responses of leaf photosynthesis and autotrophic respiration, which are typically based on short-term empirical responses. Here, we show that including longer-term responses to temperature, such as temperature acclimation, can help to reduce this uncertainty and improve model performance, leading to drastic changes in future land-atmosphere carbon feedbacks across multiple models. However, these acclimation formulations have many flaws, including an underrepresentation of many important global flora. In addition, these parameterizations were done using multiple studies that employed differing methodology. As such, we used a consistent methodology to quantify the short- and long-term temperature responses of maximum Rubisco carboxylation (Vcmax), maximum rate of Ribulos-1,5-bisphosphate regeneration (Jmax), and dark respiration (Rd) in multiple species representing each of the plant functional types used in global-scale land surface models. Short-term temperature responses of each process were measured in individuals acclimated for 7 days at one of 5 temperatures (15-35°C). The comparison of short-term curves in plants acclimated to different temperatures were used to evaluate long-term responses. Our analyses indicated that the instantaneous response of each parameter was highly sensitive to the temperature at which they were acclimated. However, we found that this sensitivity was larger in species whose leaves typically experience a greater range of temperatures over the course of their lifespan. These data indicate that models using previous acclimation formulations are likely incorrectly simulating leaf carbon exchange responses to future warming. Therefore, our data, if used to parameterize large-scale models, are likely to provide an even greater improvement in model performance, resulting in more reliable projections of future carbon-clime feedbacks.
Wavelet analysis of epileptic spikes
NASA Astrophysics Data System (ADS)
Latka, Miroslaw; Was, Ziemowit; Kozik, Andrzej; West, Bruce J.
2003-05-01
Interictal spikes and sharp waves in human EEG are characteristic signatures of epilepsy. These potentials originate as a result of synchronous pathological discharge of many neurons. The reliable detection of such potentials has been the long standing problem in EEG analysis, especially after long-term monitoring became common in investigation of epileptic patients. The traditional definition of a spike is based on its amplitude, duration, sharpness, and emergence from its background. However, spike detection systems built solely around this definition are not reliable due to the presence of numerous transients and artifacts. We use wavelet transform to analyze the properties of EEG manifestations of epilepsy. We demonstrate that the behavior of wavelet transform of epileptic spikes across scales can constitute the foundation of a relatively simple yet effective detection algorithm.
Long-Term Post-CABG Survival: Performance of Clinical Risk Models Versus Actuarial Predictions.
Carr, Brendan M; Romeiser, Jamie; Ruan, Joyce; Gupta, Sandeep; Seifert, Frank C; Zhu, Wei; Shroyer, A Laurie
2016-01-01
Clinical risk models are commonly used to predict short-term coronary artery bypass grafting (CABG) mortality but are less commonly used to predict long-term mortality. The added value of long-term mortality clinical risk models over traditional actuarial models has not been evaluated. To address this, the predictive performance of a long-term clinical risk model was compared with that of an actuarial model to identify the clinical variable(s) most responsible for any differences observed. Long-term mortality for 1028 CABG patients was estimated using the Hannan New York State clinical risk model and an actuarial model (based on age, gender, and race/ethnicity). Vital status was assessed using the Social Security Death Index. Observed/expected (O/E) ratios were calculated, and the models' predictive performances were compared using a nested c-index approach. Linear regression analyses identified the subgroup of risk factors driving the differences observed. Mortality rates were 3%, 9%, and 17% at one-, three-, and five years, respectively (median follow-up: five years). The clinical risk model provided more accurate predictions. Greater divergence between model estimates occurred with increasing long-term mortality risk, with baseline renal dysfunction identified as a particularly important driver of these differences. Long-term mortality clinical risk models provide enhanced predictive power compared to actuarial models. Using the Hannan risk model, a patient's long-term mortality risk can be accurately assessed and subgroups of higher-risk patients can be identified for enhanced follow-up care. More research appears warranted to refine long-term CABG clinical risk models. © 2015 The Authors. Journal of Cardiac Surgery Published by Wiley Periodicals, Inc.
Deformation Monitoring of Waste-Rock-Backfilled Mining Gob for Ground Control
Zhao, Tongbin; Zhang, Yubao; Zhang, Zhenyu; Li, Zhanhai; Ma, Shuqi
2017-01-01
Backfill mining is an effective option to mitigate ground subsidence, especially for mining under surface infrastructure, such as buildings, dams, rivers and railways. To evaluate its performance, continual long-term field monitoring of the deformation of backfilled gob is important to satisfy strict public scrutiny. Based on industrial Ethernet, a real-time monitoring system was established to monitor the deformation of waste-rock-backfilled gob at −700 m depth in the Tangshan coal mine, Hebei Province, China. The designed deformation sensors, based on a resistance transducer mechanism, were placed vertically between the roof and floor. Stress sensors were installed above square steel plates that were anchored to the floor strata. Meanwhile, data cables were protected by steel tubes in case of damage. The developed system continually harvested field data for three months. The results show that industrial Ethernet technology can be reliably used for long-term data transmission in complicated underground mining conditions. The monitoring reveals that the roof subsidence of the backfilled gob area can be categorized into four phases. The bearing load of the backfill developed gradually and simultaneously with the deformation of the roof strata, and started to be almost invariable when the mining face passed 97 m. PMID:28475168
Deformation Monitoring of Waste-Rock-Backfilled Mining Gob for Ground Control.
Zhao, Tongbin; Zhang, Yubao; Zhang, Zhenyu; Li, Zhanhai; Ma, Shuqi
2017-05-05
Backfill mining is an effective option to mitigate ground subsidence, especially for mining under surface infrastructure, such as buildings, dams, rivers and railways. To evaluate its performance, continual long-term field monitoring of the deformation of backfilled gob is important to satisfy strict public scrutiny. Based on industrial Ethernet, a real-time monitoring system was established to monitor the deformation of waste-rock-backfilled gob at -700 m depth in the Tangshan coal mine, Hebei Province, China. The designed deformation sensors, based on a resistance transducer mechanism, were placed vertically between the roof and floor. Stress sensors were installed above square steel plates that were anchored to the floor strata. Meanwhile, data cables were protected by steel tubes in case of damage. The developed system continually harvested field data for three months. The results show that industrial Ethernet technology can be reliably used for long-term data transmission in complicated underground mining conditions. The monitoring reveals that the roof subsidence of the backfilled gob area can be categorized into four phases. The bearing load of the backfill developed gradually and simultaneously with the deformation of the roof strata, and started to be almost invariable when the mining face passed 97 m.
Schaeffer, Jeff; Rogers, Mark W.; Fielder, David G.; Godby, Neal; Bowen, Anjanette K.; O'Connor, Lisa; Parrish, Josh; Greenwood, Susan; Chong, Stephen; Wright, Greg
2014-01-01
Long-term surveys are useful in understanding trends in connecting channel fish communities; a gill net assessment in the Saint Marys River performed periodically since 1975 is the most comprehensive connecting channels sampling program within the Laurentian Great Lakes. We assessed efficiency of that survey, with intent to inform development of assessments at other connecting channels. We evaluated trends in community composition, effort versus estimates of species richness, ability to detect abundance changes for four species, and effects of subsampling yellow perch catches on size and age-structure metrics. Efficiency analysis revealed low power to detect changes in species abundance, whereas reduced effort could be considered to index species richness. Subsampling simulations indicated that subsampling would have allowed reliable estimates of yellow perch (Perca flavescens) population structure, while greatly reducing the number of fish that were assigned ages. Analyses of statistical power and efficiency of current sampling protocols are useful for managers collecting and using these types of data as well as for the development of new monitoring programs. Our approach provides insight into whether survey goals and objectives were being attained and can help evaluate ability of surveys to answer novel questions that arise as management strategies are refined.
Agarwal, Vivek; Buttles, John W.; Beaty, Lawrence H.; ...
2016-10-05
In the current competitive energy market, the nuclear industry is committed to lower the operations and maintenance cost; increase productivity and efficiency while maintaining safe and reliable operation. The present operating model of nuclear power plants is dependent on large technical staffs that put the nuclear industry at long-term economic disadvantage. Technology can play a key role in nuclear power plant configuration management in offsetting labor costs by automating manually performed plant activities. The technology being developed, tested, and demonstrated in this paper will enable the continued safe operation of today’s fleet of light water reactors by providing the technicalmore » means to monitor components in plants today that are only routinely monitored through manual activities. The wireless enabled valve position indicators that are the subject of this paper are able to provide a valid position indication available continuously, rather than only periodically. As a result, a real-time (online) availability of valve positions using an affordable technologies are vital to plant configuration when compared with long-term labor rates, and provide information that can be used for a variety of plant engineering, maintenance, and management applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agarwal, Vivek; Buttles, John W.; Beaty, Lawrence H.
In the current competitive energy market, the nuclear industry is committed to lower the operations and maintenance cost; increase productivity and efficiency while maintaining safe and reliable operation. The present operating model of nuclear power plants is dependent on large technical staffs that put the nuclear industry at long-term economic disadvantage. Technology can play a key role in nuclear power plant configuration management in offsetting labor costs by automating manually performed plant activities. The technology being developed, tested, and demonstrated in this paper will enable the continued safe operation of today’s fleet of light water reactors by providing the technicalmore » means to monitor components in plants today that are only routinely monitored through manual activities. The wireless enabled valve position indicators that are the subject of this paper are able to provide a valid position indication available continuously, rather than only periodically. As a result, a real-time (online) availability of valve positions using an affordable technologies are vital to plant configuration when compared with long-term labor rates, and provide information that can be used for a variety of plant engineering, maintenance, and management applications.« less
Managing high-bandwidth real-time data storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bigelow, David D.; Brandt, Scott A; Bent, John M
2009-09-23
There exist certain systems which generate real-time data at high bandwidth, but do not necessarily require the long-term retention of that data in normal conditions. In some cases, the data may not actually be useful, and in others, there may be too much data to permanently retain in long-term storage whether it is useful or not. However, certain portions of the data may be identified as being vitally important from time to time, and must therefore be retained for further analysis or permanent storage without interrupting the ongoing collection of new data. We have developed a system, Mahanaxar, intended tomore » address this problem. It provides quality of service guarantees for incoming real-time data streams and simultaneous access to already-recorded data on a best-effort basis utilizing any spare bandwidth. It has built in mechanisms for reliability and indexing, can scale upwards to meet increasing bandwidth requirements, and handles both small and large data elements equally well. We will show that a prototype version of this system provides better performance than a flat file (traditional filesystem) based version, particularly with regard to quality of service guarantees and hard real-time requirements.« less
NASA Astrophysics Data System (ADS)
Pohl, E.; Maximini, M.; Bauschulte, A.; vom Schloß, J.; Hermanns, R. T. E.
2015-02-01
HT-PEM fuel cells suffer from performance losses due to degradation effects. Therefore, the durability of HT-PEM is currently an important factor of research and development. In this paper a novel approach is presented for an integrated short term and long term simulation of HT-PEM accelerated lifetime testing. The physical phenomena of short term and long term effects are commonly modeled separately due to the different time scales. However, in accelerated lifetime testing, long term degradation effects have a crucial impact on the short term dynamics. Our approach addresses this problem by applying a novel method for dual time scale simulation. A transient system simulation is performed for an open voltage cycle test on a HT-PEM fuel cell for a physical time of 35 days. The analysis describes the system dynamics by numerical electrochemical impedance spectroscopy. Furthermore, a performance assessment is performed in order to demonstrate the efficiency of the approach. The presented approach reduces the simulation time by approximately 73% compared to conventional simulation approach without losing too much accuracy. The approach promises a comprehensive perspective considering short term dynamic behavior and long term degradation effects.
A major goal of research on the long-term performance of subsurface reactive barriers is to identify standard ground water monitoring parameters that may be useful indicators of declining performance or impending system failure. Results are presented from ground water monitoring ...
A major goal of research on the long-term performance of subsurface reactive barriers is to identify standard ground-water monitoring parameters that may be useful indicators of declining performance or impending system failure. Results are presented from studies conducted over ...
Ezerarslan, Hande; Beriat, Güçlü Kaan; Nurhat, Raziye Handan; Kazancı, Burak; Çelikkan, Ferda Topal; Sabuncuoğlu, Bizden; Sabuncuoğlu, Hakan
2016-08-01
We aimed to find out the effects of short term and long term hydrocephalus and intracranial ventricular volume changes on cochlear functions by using distortion product otoacoustic emission (DPOAE) in experimental hydrocephalus rat models for the first time in literature. This study was performed with 48 healthy, adult (8 weeks old), Sprague-Dawley rats which weighed between 200 and 240g. Six groups were formed in this study: short term control, short term sham, short term hydrocephalus, long term control, long term sham and long term hydrocephalus groups. Each group contained eight rats. Short term period was 4 weeks and long term period was 8 weeks after the study started. At the end of these periods, DPOAE measurements were performed and then rats were sacrificed to determine ventricular volumes. DPOAE values at all frequencies were significantly decreased in the short term hydrocephalus group when compared to the short term control and short term sham groups. DPOAE values at all frequencies were significantly decreased in the long term hydrocephalus group when compared to the long term control and long term sham groups. Besides, long term sham group which had higher ventricular volumes than long term control group also had lower DPOAE measurements. Significant associations were present between DPOAE measurements and ventricular volumes in hydrocephalus models. The functional disturbances in cochlear functions due to hydrocephalus have been demonstrated with DPOAE measurements in this study. DPOAE measurements may be thought as an easily applicable non-invasive method in detection and follow-up of patients with hydrocephalus. Our findings should be supported with clinical studies in humans. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sharma, Asha; Rieth, Loren; Tathireddy, Prashant; Harrison, Reid; Solzbacher, Florian
2010-02-01
We herein report in vitro functional stability and recording longevity of a fully integrated wireless neural interface (INI). The INI uses biocompatible Parylene-C as an encapsulation layer, and was immersed in phosphate buffered saline (PBS) for a period of over 150 days. The full functionality (wireless radio-frequency power, command, and signal transmission) and the ability of INI to record artificial action potentials even after 150 days of PBS soaking without any change in signal/noise amplitude constitutes a major milestone in long term stability, and evaluate the encapsulation reliability, functional stability, and potential usefulness for future chronic implants.
Childress, Carolyn J. Oblinger; Foreman, William T.; Connor, Brooke F.; Maloney, Thomas J.
1999-01-01
This report describes the U.S. Geological Survey National Water Quality Laboratory?s approach for determining long-term method detection levels and establishing reporting levels, details relevant new reporting conventions, and provides preliminary guidance on interpreting data reported with the new conventions. At the long-term method detection level concentration, the risk of a false positive detection (analyte reported present at the long-term method detection level when not in sample) is no more than 1 percent. However, at the long-term method detection level, the risk of a false negative occurrence (analyte reported not present when present at the long-term method detection level concentration) is up to 50 percent. Because this false negative rate is too high for use as a default 'less than' reporting level, a more reliable laboratory reporting level is set at twice the determined long-term method detection level. For all methods, concentrations measured between the laboratory reporting level and the long-term method detection level will be reported as estimated concentrations. Non-detections will be censored to the laboratory reporting level. Adoption of the new reporting conventions requires a full understanding of how low-concentration data can be used and interpreted and places responsibility for using and presenting final data with the user rather than with the laboratory. Users must consider that (1) new laboratory reporting levels may differ from previously established minimum reporting levels, (2) long-term method detection levels and laboratory reporting levels may change over time, and (3) estimated concentrations are less certain than concentrations reported above the laboratory reporting level. The availability of uncensored but qualified low-concentration data for interpretation and statistical analysis is a substantial benefit to the user. A decision to censor data after they are reported from the laboratory may still be made by the user, if merited, on the basis of the intended use of the data.