Zhang, Xuena; Wu, Anshi; Yao, Shanglong; Xue, Zhanggang; Yue, Yun
2015-01-01
Background The CONCERT-CL closed-loop infusion system designed by VERYARK Technology Co., Ltd. (Guangxi, China) is an innovation using TCI combined with closed-loop controlled intravenous anesthesia under the guide of BIS. In this study we performed a randomized, controlled, multicenter study to compare closed-loop control and open-loop control of propofol by using the CONCERT-CL closed-loop infusion system. Methods 180 surgical patients from three medical centers undergone TCI intravenous anesthesia with propofol and remifentanil were randomly assigned to propofol closed-loop group and propofol opened-loop groups. Primary outcome was global score (GS, GS = (MDAPE+Wobble)/% of time of bispectral index (BIS) 40-60). Secondary outcomes were doses of the anesthetics and emergence time from anesthesia, such as, time to tracheal extubation. Results There were 89 and 86 patients in the closed-loop and opened-loop groups, respectively. GS in the closed-loop groups (22.21±8.50) were lower than that in the opened-loop group (27.19±15.26) (p=0.009). The higher proportion of time of BIS between 40 and 60 was also observed in the closed-loop group (84.11±9.50%), while that was 79.92±13.17% in the opened-loop group, (p=0.016). No significant differences in propofol dose and time of tracheal extubation were observed. The frequency of propofol regulation in the closed-loop group (31.55±9.46 times/hr) was obverse higher than that in the opened-loop group (6.84±6.21 times/hr) (p=0.000). Conclusion The CONCERT-CL closed-loop infusion system can automatically regulate the TCI of propofol, maintain the BIS value in an adequate range and reduce the workload of anesthesiologists better than open-loop system. Trial Registration ChiCTR ChiCTR-OOR-14005551 PMID:25886041
Comparison of individual and pooled sampling methods for detecting bacterial pathogens of fish
Mumford, Sonia; Patterson, Chris; Evered, J.; Brunson, Ray; Levine, J.; Winton, J.
2005-01-01
Examination of finfish populations for viral and bacterial pathogens is an important component of fish disease control programs worldwide. Two methods are commonly used for collecting tissue samples for bacteriological culture, the currently accepted standards for detection of bacterial fish pathogens. The method specified in the Office International des Epizooties Manual of Diagnostic Tests for Aquatic Animals permits combining renal and splenic tissues from as many as 5 fish into pooled samples. The American Fisheries Society (AFS) Blue Book/US Fish and Wildlife Service (USFWS) Inspection Manual specifies the use of a bacteriological loop for collecting samples from the kidney of individual fish. An alternative would be to more fully utilize the pooled samples taken for virology. If implemented, this approach would provide substantial savings in labor and materials. To compare the relative performance of the AFS/USFWS method and this alternative approach, cultures of Yersinia ruckeri were used to establish low-level infections in groups of rainbow trout (Oncorhynchus mykiss) that were sampled by both methods. Yersinia ruckeri was cultured from 22 of 37 groups by at least 1 method. The loop method yielded 18 positive groups, with 1 group positive in the loop samples but negative in the pooled samples. The pooled samples produced 21 positive groups, with 4 groups positive in the pooled samples but negative in the loop samples. There was statistically significant agreement (Spearman coefficient 0.80, P < 0.001) in the relative ability of the 2 sampling methods to permit detection of low-level bacterial infections of rainbow trout.
NASA Astrophysics Data System (ADS)
Rück, Marlon; Reuther, Johannes
2018-04-01
We implement an extension of the pseudofermion functional renormalization group method for quantum spin systems that takes into account two-loop diagrammatic contributions. An efficient numerical treatment of the additional terms is achieved within a nested graph construction which recombines different one-loop interaction channels. In order to be fully self-consistent with respect to self-energy corrections, we also include certain three-loop terms of Katanin type. We first apply this formalism to the antiferromagnetic J1-J2 Heisenberg model on the square lattice and benchmark our results against the previous one-loop plus Katanin approach. Even though the renormalization group (RG) equations undergo significant modifications when including the two-loop terms, the magnetic phase diagram, comprising Néel ordered and collinear ordered phases separated by a magnetically disordered regime, remains remarkably unchanged. Only the boundary position between the disordered and the collinear phases is found to be moderately affected by two-loop terms. On the other hand, critical RG scales, which we associate with critical temperatures Tc, are reduced by a factor of ˜2 indicating that the two-loop diagrams play a significant role in enforcing the Mermin-Wagner theorem. Improved estimates for critical temperatures are also obtained for the Heisenberg ferromagnet on the three-dimensional simple cubic lattice where errors in Tc are reduced by ˜34 % . These findings have important implications for the quantum phase diagrams calculated within the previous one-loop plus Katanin approach which turn out to be already well converged.
Universality hypothesis breakdown at one-loop order
NASA Astrophysics Data System (ADS)
Carvalho, P. R. S.
2018-05-01
We probe the universality hypothesis by analytically computing the at least two-loop corrections to the critical exponents for q -deformed O (N ) self-interacting λ ϕ4 scalar field theories through six distinct and independent field-theoretic renormalization group methods and ɛ -expansion techniques. We show that the effect of q deformation on the one-loop corrections to the q -deformed critical exponents is null, so the universality hypothesis is broken down at this loop order. Such an effect emerges only at the two-loop and higher levels, and the validity of the universality hypothesis is restored. The q -deformed critical exponents obtained through the six methods are the same and, furthermore, reduce to their nondeformed values in the appropriated limit.
A novel method for reducing gap formation in tendon repair.
Dean, Ryan; Sethi, Paul
2018-03-01
This study investigates gap formation in tendon repair using a novel tensioning method. The novel stitch will demonstrate less gap formation than the other suture configurations tested. Porcine tendons stitched with classic Krackow stitch configurations were compared to a Krackow stitch modified with a proximal Tension-Assist Loop. Each group was cyclically loaded followed by analysis of the tendon-suture construct for gap formation. The Tension-Assist Loop group produced significantly less gap formation than each of the other stitch groups. Decreasing early gap formation may be beneficial in allowing early rehabilitation and range of motion.
Network community structure and loop coefficient method
NASA Astrophysics Data System (ADS)
Vragović, I.; Louis, E.
2006-07-01
A modular structure, in which groups of tightly connected nodes could be resolved as separate entities, is a property that can be found in many complex networks. In this paper, we propose a algorithm for identifying communities in networks. It is based on a local measure, so-called loop coefficient that is a generalization of the clustering coefficient. Nodes with a large loop coefficient tend to be core inner community nodes, while other vertices are usually peripheral sites at the borders of communities. Our method gives satisfactory results for both artificial and real-world graphs, if they have a relatively pronounced modular structure. This type of algorithm could open a way of interpreting the role of nodes in communities in terms of the local loop coefficient, and could be used as a complement to other methods.
Rigó, István Zoltán; Røkkum, Magne
2013-12-01
We compared the results of two methods for reinsertion of flexor digitorum profundus tendons retrospectively. In 35 fingers of 29 patients pull-out suture and in 13 fingers of 11 patients transverse intraosseous loop technique was performed with a mean follow-up of 8 and 6 months, respectively. Eleven and nine fingers achieved "excellent" or "good" function according to Strickland and Glogovac at 8 weeks; 20 and ten at the last control in the pull-out and transverse intraosseous loop groups, respectively. The difference at 8 weeks was statistically significant in favour of the transverse intraosseous loop group. Ten patients underwent 12 complications in the pull-out group (four superficial infections; one rerupture, one PIP and one DIP joint contracture, one adhesion, two granulomas, one nail deformity and one carpal tunnel syndrome) and four of them were reoperated (one carpal tunnel release, one teno-arthrolysis and two resections of granuloma). There was no complication and no reoperation in the transverse intraosseous loop group, the difference being statistically significant for the former. In our study the transverse intraosseous loop technique seemed to be a safe alternative with possibly better functional results compared to the pull-out suture.
Mining protein loops using a structural alphabet and statistical exceptionality
2010-01-01
Background Protein loops encompass 50% of protein residues in available three-dimensional structures. These regions are often involved in protein functions, e.g. binding site, catalytic pocket... However, the description of protein loops with conventional tools is an uneasy task. Regular secondary structures, helices and strands, have been widely studied whereas loops, because they are highly variable in terms of sequence and structure, are difficult to analyze. Due to data sparsity, long loops have rarely been systematically studied. Results We developed a simple and accurate method that allows the description and analysis of the structures of short and long loops using structural motifs without restriction on loop length. This method is based on the structural alphabet HMM-SA. HMM-SA allows the simplification of a three-dimensional protein structure into a one-dimensional string of states, where each state is a four-residue prototype fragment, called structural letter. The difficult task of the structural grouping of huge data sets is thus easily accomplished by handling structural letter strings as in conventional protein sequence analysis. We systematically extracted all seven-residue fragments in a bank of 93000 protein loops and grouped them according to the structural-letter sequence, named structural word. This approach permits a systematic analysis of loops of all sizes since we consider the structural motifs of seven residues rather than complete loops. We focused the analysis on highly recurrent words of loops (observed more than 30 times). Our study reveals that 73% of loop-lengths are covered by only 3310 highly recurrent structural words out of 28274 observed words). These structural words have low structural variability (mean RMSd of 0.85 Å). As expected, half of these motifs display a flanking-region preference but interestingly, two thirds are shared by short (less than 12 residues) and long loops. Moreover, half of recurrent motifs exhibit a significant level of amino-acid conservation with at least four significant positions and 87% of long loops contain at least one such word. We complement our analysis with the detection of statistically over-represented patterns of structural letters as in conventional DNA sequence analysis. About 30% (930) of structural words are over-represented, and cover about 40% of loop lengths. Interestingly, these words exhibit lower structural variability and higher sequential specificity, suggesting structural or functional constraints. Conclusions We developed a method to systematically decompose and study protein loops using recurrent structural motifs. This method is based on the structural alphabet HMM-SA and not on structural alignment and geometrical parameters. We extracted meaningful structural motifs that are found in both short and long loops. To our knowledge, it is the first time that pattern mining helps to increase the signal-to-noise ratio in protein loops. This finding helps to better describe protein loops and might permit to decrease the complexity of long-loop analysis. Detailed results are available at http://www.mti.univ-paris-diderot.fr/publication/supplementary/2009/ACCLoop/. PMID:20132552
Mining protein loops using a structural alphabet and statistical exceptionality.
Regad, Leslie; Martin, Juliette; Nuel, Gregory; Camproux, Anne-Claude
2010-02-04
Protein loops encompass 50% of protein residues in available three-dimensional structures. These regions are often involved in protein functions, e.g. binding site, catalytic pocket... However, the description of protein loops with conventional tools is an uneasy task. Regular secondary structures, helices and strands, have been widely studied whereas loops, because they are highly variable in terms of sequence and structure, are difficult to analyze. Due to data sparsity, long loops have rarely been systematically studied. We developed a simple and accurate method that allows the description and analysis of the structures of short and long loops using structural motifs without restriction on loop length. This method is based on the structural alphabet HMM-SA. HMM-SA allows the simplification of a three-dimensional protein structure into a one-dimensional string of states, where each state is a four-residue prototype fragment, called structural letter. The difficult task of the structural grouping of huge data sets is thus easily accomplished by handling structural letter strings as in conventional protein sequence analysis. We systematically extracted all seven-residue fragments in a bank of 93000 protein loops and grouped them according to the structural-letter sequence, named structural word. This approach permits a systematic analysis of loops of all sizes since we consider the structural motifs of seven residues rather than complete loops. We focused the analysis on highly recurrent words of loops (observed more than 30 times). Our study reveals that 73% of loop-lengths are covered by only 3310 highly recurrent structural words out of 28274 observed words). These structural words have low structural variability (mean RMSd of 0.85 A). As expected, half of these motifs display a flanking-region preference but interestingly, two thirds are shared by short (less than 12 residues) and long loops. Moreover, half of recurrent motifs exhibit a significant level of amino-acid conservation with at least four significant positions and 87% of long loops contain at least one such word. We complement our analysis with the detection of statistically over-represented patterns of structural letters as in conventional DNA sequence analysis. About 30% (930) of structural words are over-represented, and cover about 40% of loop lengths. Interestingly, these words exhibit lower structural variability and higher sequential specificity, suggesting structural or functional constraints. We developed a method to systematically decompose and study protein loops using recurrent structural motifs. This method is based on the structural alphabet HMM-SA and not on structural alignment and geometrical parameters. We extracted meaningful structural motifs that are found in both short and long loops. To our knowledge, it is the first time that pattern mining helps to increase the signal-to-noise ratio in protein loops. This finding helps to better describe protein loops and might permit to decrease the complexity of long-loop analysis. Detailed results are available at http://www.mti.univ-paris-diderot.fr/publication/supplementary/2009/ACCLoop/.
Medial Meniscal Root Avulsion: A Biomechanical Comparison of 4 Different Repair Constructs.
Mitchell, Richard; Pitts, Ryan; Kim, Young-Mo; Matava, Matthew J
2016-01-01
To evaluate the time-zero load-to-failure strength of 4 different constructs used to repair medial meniscal root avulsions. Sixty fresh-frozen cadaveric knees with a mean age of 74 years were used for this study. Each knee was dissected to isolate the attachment of the posterior root of the medial meniscus to the tibial plateau. An Instron machine (Instron, Norwood, MA) with a custom-designed clamp was used to avulse the intact posterior meniscal root in 12 control specimens. An additional 48 specimens were tested after transection of the native meniscal root to evaluate the pullout strength of 4 different repair constructs using No. 0 FiberWire suture (Arthrex, Naples, FL): a single suture (n = 12), a double suture (n = 12), a loop stitch (n = 12), and a locking loop stitch (n = 12). Analysis of variance was used to compare load to failure and stiffness of all 4 groups; pair-wise, between-group differences were also assessed. Repair failure occurred most commonly by suture pullout in 94% of the specimens in the repair groups. For the controls, failure occurred most commonly at the meniscus-clamp interface. Failure load was highest for the control group (mean, 359.5 ± 168 N), followed in descending order by the locking loop stitch (191.4 ± 45.1 N), loop stitch (119.6 ± 55.0 N), double suture (96.2 ± 51.4 N), and single suture (58.2 ± 29.6 N). The control group was significantly stronger than 3 of the experimental groups (single suture [95% CI, 3.8 to 11.3], double suture [95% CI, 2.1 to 6.4], and loop stitch [95% CI, 2.0 to 4.5]; P < .0001) but not the locking loop stitch (P = .003; 95% CI, 1.2 to 3.2). The locking loop stitch was significantly stronger than the single suture (P < .0001; 95% CI, 2.0 to 5.4) and double suture (P = .003; 95% CI, 1.2 to 2.9). The locking loop stitch was significantly stiffer than the single suture (P < .0001; 95% CI, 3.8 to 20.3), double suture (P < .0001; 95% CI, 2.0 to 9.8), and loop stitch (P = .03; 95% CI, 1.1 to 5.5) but not significantly different from the control group (P = .93; 95% CI, 0.3 to 1.9). Age and gender had no effect on pullout strength. The results of this study show that the locking loop stitch provided time-zero load-to-failure strength that most closely approximated the strength of the native meniscal root in addition to being significantly stronger and stiffer than 3 other commonly used repair methods. The true strength of the native meniscal root is unknown based on limitations with our testing methodology. The locking loop stitch exhibited the highest load to failure and stiffness of the 4 fixation methods tested, despite the fact that none of the fixation methods replicated the strength of the intact meniscal root. It is currently unknown what strength of fixation is required for healing of meniscal root repairs. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Shashidhar, Nagam Reddy; Reddy, S.Rama Koteswara
2016-01-01
Introduction Molar distalization is the non extraction method of managing Class II malocclusions. Aim The purpose of this study was to evaluate the skeletal and dentoalveolar effects of maxillary molar distalization with K-loop appliance, and to compare these effects with that of pendulum group. Materials and Methods Class I and dental Class II malocclusions were divided into two groups of 15 each: In Group 1 (nine females and six males; mean age, 16.0±2.6 years) patients were treated with K-Loop molar distalization supported palatally by Nance button, while in Group 2 (seven females and eight males; mean age, 15.4±4.7 years), the patients were treated with conventional pendulum appliance. Standardized lateral cephalograms were taken at the beginning of treatment (T0) and at the end of molar distalization (T1) and the changes were statistically analyzed with paired t-test. Results The results showed no statistically significant difference in the amount of molar distalization in either of the appliance groups: the mean amount of molar distal movement of 5.1±0.8 mm and 4.93±1.68 mm was observed in the Group 1 and 2 respectively. The incisors moved mesially by 1.3±0.63 mm in Group 1 and 1.57±0.58 mm in Group 2. Conclusion K-Loop molar distalizing appliance has similar skeletal and dentoalveolar effects as that of pendulum appliance, with the advantages of simple yet efficient to control the moment-force ratio to produce all types of tooth movements and also requires minimal patient co-operation. PMID:27504403
Loop Variables in String Theory
NASA Astrophysics Data System (ADS)
Sathiapalan, B.
The loop variable approach is a proposal for a gauge-invariant generalization of the sigma-model renormalization group method of obtaining equations of motion in string theory. The basic guiding principle is space-time gauge invariance rather than world sheet properties. In essence it is a version of Wilson's exact renormalization group equation for the world sheet theory. It involves all the massive modes and is defined with a finite world sheet cutoff, which allows one to go off the mass-shell. On shell the tree amplitudes of string theory are reproduced. The equations are gauge-invariant off shell also. This paper is a self-contained discussion of the loop variable approach as well as its connection with the Wilsonian RG.
The serpentine optical waveguide: engineering the dispersion relations and the stopped light points.
Scheuer, Jacob; Weiss, Ori
2011-06-06
We present a study a new type of optical slow-light structure comprising a serpentine shaped waveguide were the loops are coupled. The dispersion relation, group velocity and GVD are studied analytically using a transfer matrix method and numerically using finite difference time domain simulations. The structure exhibits zero group velocity points at the ends of the Brillouin zone, but also within the zone. The position of mid-zone zero group velocity point can be tuned by modifying the coupling coefficient between adjacent loops. Closed-form analytic expressions for the dispersion relations, group velocity and the mid-zone zero v(g) points are found and presented.
Diagram reduction in problem of critical dynamics of ferromagnets: 4-loop approximation
NASA Astrophysics Data System (ADS)
Adzhemyan, L. Ts; Ivanova, E. V.; Kompaniets, M. V.; Vorobyeva, S. Ye
2018-04-01
Within the framework of the renormalization group approach to the models of critical dynamics, we propose a method for a considerable reduction of the number of integrals needed to calculate the critical exponents. With this method we perform a calculation of the critical exponent z of model A at 4-loop level, where our method allows one to reduce the number of integrals from 66 to 17. The way of constructing the integrand in a Feynman representation of such diagrams is discussed. Integrals were estimated numerically with a sector decomposition technique.
The application of cluster analysis in the intercomparison of loop structures in RNA.
Huang, Hung-Chung; Nagaswamy, Uma; Fox, George E
2005-04-01
We have developed a computational approach for the comparison and classification of RNA loop structures. Hairpin or interior loops identified in atomic resolution RNA structures were intercompared by conformational matching. The root-mean-square deviation (RMSD) values between all pairs of RNA fragments of interest, even if from different molecules, are calculated. Subsequently, cluster analysis is performed on the resulting matrix of RMSD distances using the unweighted pair group method with arithmetic mean (UPGMA). The cluster analysis objectively reveals groups of folds that resemble one another. To demonstrate the utility of the approach, a comprehensive analysis of all the terminal hairpin tetraloops that have been observed in 15 RNA structures that have been determined by X-ray crystallography was undertaken. The method found major clusters corresponding to the well-known GNRA and UNCG types. In addition, two tetraloops with the unusual primary sequence UMAC (M is A or C) were successfully assigned to the GNRA cluster. Larger loop structures were also examined and the clustering results confirmed the occurrence of variations of the GNRA and UNCG tetraloops in these loops and provided a systematic means for locating them. Nineteen examples of larger loops that closely resemble either the GNRA or UNCG tetraloop were found in the large ribosomal RNAs. When the clustering approach was extended to include all structures in the SCOR database, novel relationships were detected including one between the ANYA motif and a less common folding of the GAAA tetraloop sequence.
The application of cluster analysis in the intercomparison of loop structures in RNA
HUANG, HUNG-CHUNG; NAGASWAMY, UMA; FOX, GEORGE E.
2005-01-01
We have developed a computational approach for the comparison and classification of RNA loop structures. Hairpin or interior loops identified in atomic resolution RNA structures were intercompared by conformational matching. The root-mean-square deviation (RMSD) values between all pairs of RNA fragments of interest, even if from different molecules, are calculated. Subsequently, cluster analysis is performed on the resulting matrix of RMSD distances using the unweighted pair group method with arithmetic mean (UPGMA). The cluster analysis objectively reveals groups of folds that resemble one another. To demonstrate the utility of the approach, a comprehensive analysis of all the terminal hairpin tetraloops that have been observed in 15 RNA structures that have been determined by X-ray crystallography was undertaken. The method found major clusters corresponding to the well-known GNRA and UNCG types. In addition, two tetraloops with the unusual primary sequence UMAC (M is A or C) were successfully assigned to the GNRA cluster. Larger loop structures were also examined and the clustering results confirmed the occurrence of variations of the GNRA and UNCG tetraloops in these loops and provided a systematic means for locating them. Nineteen examples of larger loops that closely resemble either the GNRA or UNCG tetraloop were found in the large ribosomal RNAs. When the clustering approach was extended to include all structures in the SCOR database, novel relationships were detected including one between the ANYA motif and a less common folding of the GAAA tetraloop sequence. PMID:15769871
Niessen, Ludwig
2015-01-01
Loop-mediated isothermal amplification is a rather novel method of enzymatic deoxyribonucleic acid amplification which can be applied for the diagnosis of viruses, bacteria, and fungi. Although firmly established in viral and bacterial diagnosis, the technology has only recently been applied to a noteworthy number of species in the filamentous fungi and yeasts. The current review gives an overview of the literature so far published on the topic by discussing the different groups of fungal organisms to which the method has been applied. Moreover, the method is described in detail as well as the different possibilities available for signal detection and quantification and sample preparation. Future perspective of loop-mediated isothermal amplification-based assays is discussed in the light of applicability for fungal diagnostics.
Fingerprints as an Alternative Method to Determine ABO and Rh Blood Groups.
Chaudhary, Sonam; Deuja, Sajana; Alam, Munna; Karmacharya, Poonam; Mondal, Monami
2017-01-01
Blood grouping is conventionally done with invasive method by taking blood samples. The objective of this study is to determine blood group with uninvasive procedure by taking fingerprints of the participants and know the associations between their fingerprints and blood groups. Seven hundred participants of both genders with no any age limitation from Manipal Teaching Hospital and Manipal College of Medical Sciences were randomly selected. The blood grouping was done by cross reacting blood sample with the antibodies. The fingerprints were taken with the help of stamp pad imprinting the finger ridges over A4 size white papers. The loop, whorl and arch patterns were studied. O+ve blood group 224 (32%) was most prevalent among 700 participants. The loop pattern was highly distributed 3708 (53%) in all blood groups except in A-ve blood group with highest distribution of whorl 20 (40%). The mean comparisons of specific fingerprint in total and also in individual fingers with different ABO and ABO-Rh blood groups showed no any statistical association with P>0.05. However, the loop distribution in individual finger was highest in right middle finger (M) of B-ve blood group 5 (10%). The whorl distribution in individual finger was highest in right index (I), left thumb (T) and left ring (R) fingers of AB+ve blood group 20 (5.5% each). Similarly, the arch distribution was highest in right index fingers of A-ve blood group 3 (6%). The mean comparison of different fingerprints with ABO and Rh blood groups showed no significant statistical association concluding fingerprints cannot be used for blood grouping.
A proposal for a tailored approach to diverting ostomy for colorectal anastomosis.
Manzenreiter, Lisa; Spaun, Georg; Weitzendorfer, Michael; Luketina, Rosalia; Antoniou, Stavros A; Wundsam, Helwig; Koch, Oliver O; Emmanuel, Klaus
2018-02-01
The use of a protective stoma represents an important issue in colorectal surgery. Although evidence suggests that loop ileostomy may be superior, the optimal method for temporary decompression of colorectal anastomosis still remains controversial. Aim of this study was to make an evidence-based proposal for a tailored approach to the use of diverting colostomy or ileostomy. A retrospective analysis of all patients subjected to creation and closure of a diverting loop colostomy or loop ileostomy between May 2007 and November 2014 in our institution was performed. Early and late complications, mortality and morbidity, time between formation and closure of the stoma in respect to adjuvant chemotherapy and the length of hospital stay were assessed and compared between the two groups. Outcomes of 167 patients (m=95; f=72) undergoing a loop colostomy (N.=130) or ileostomy (N.=37) were analyzed. The most frequent diagnosis was malignancy (64.1%), followed by abdominal emergency operations (18.6%) and complicated diverticular disease (17.4%). There was no mortality. Adjuvant chemotherapy (26.3%) resulted in delayed stoma reversal (P<0.001). Complications following construction of the stoma such as electrolyte disorder (P<0.001), renal insufficiency (P=0.048), and skin irritation (P=0.003) occurred significantly more often within the ileostomy group. Within the colostomy group, the rate of stoma prolapse (P=0.074) tended to be higher. Both methods have advantages and disadvantages. Loop transverse colostomy could be the preferred technique for older patients to avoid electrolyte disorder and renal insufficiency. Further prospective trials with documentation of electrolyte metabolism and quality of life should follow.
Usage of mitochondrial D-loop variation to predict risk for Huntington disease.
Mousavizadeh, Kazem; Rajabi, Peyman; Alaee, Mahsa; Dadgar, Sepideh; Houshmand, Massoud
2015-08-01
Huntington's disease (HD) is an inherited autosomal neurodegenerative disease caused by the abnormal expansion of the CAG repeats in the Huntingtin (Htt) gene. It has been proven that mitochondrial dysfunction is contributed to the pathogenesis of Huntington's disease. The mitochondrial displacement loop (D-loop) is proven to accumulate mutations at a higher rate than other regions of mtDNA. Thus, we hypothesized that specific SNPs in the D-loop may contribute to the pathogenesis of Huntington's disease. In the present study, 30 patients with Huntington's disease and 463 healthy controls were evaluated for mitochondrial mutation sites within the D-loop region using PCR-sequencing method. Sequence analysis revealed 35 variations in HD group from Cambridge Mitochondrial Sequences. A significant difference (p < 0.05) was seen between patients and control group in eight SNPs. Polymorphisms at C16069T, T16126C, T16189C, T16519C and C16223T were correlated with an increased risk of HD while SNPs at C16150T, T16086C and T16195C were associated with a decreased risk of Huntington's disease.
Hypnosis closed loop TCI systems in outpatient surgery.
Ramos-Luengo, A; Asensio-Merino, F
Determine the influence of general anaesthesia with closed-loop systems in the results of outpatient varicose vein surgery. Retrospective observational study including data from 270 outpatients between 2014 and 2015. The patients were divided into 2 groups according to the type of general anaesthesia used. The CL Group included patients who received propofol in closed-loop guided by BIS and remifentanil using TCI, and the C Group received non-closed-loop anaesthesia. Age, sex, surgical time, discharge time and failure of outpatient surgery were recorded. Quantitative data were checked for normal distribution by the method of Kolmogorov-Smirnov-Lilliefors. Differences between groups were analysed by a Student-t-test or Mann-Whitney-Wilcoxon test, depending on their distribution. Categorical data were analysed by a Chi-squared test. We used Kaplan-Meier estimator and the effect size (calculated by Cohen's d) to study the discharge time. Statistical analysis was performed using R 3.2.3 binary for Mac OS X 10.9. There were no significant differences in age, sex and surgical time and failure of outpatient surgery. Discharge time was different in both groups: 200 (100) vs. 180 (82.5) minutes, C Group and CL Group, respectively (data are median and interquartile rank); P=.005. The use of closed-loop devices for the hypnotic component of anaesthesia hastens discharge time. However, for this effect to be clinically significant, some improvements still need to be made in our outpatient surgery units. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Liver Resections Combined with Closure of Loop Ileostomies: A Retrospective Analysis
Lordan, Jeffrey T.; Riga, Angela T.; Karanjia, Nariman D.
2008-01-01
Background. The management of patients with colorectal liver metastases and loop ileostomies remains controversial. This study was performed to assess the outcome of combined liver resection and loop ileostomy closure. Methods. Analysis of prospectively collected perioperative data, including morbidity and mortality, of 283 consecutive hepatectomies for colorectal liver metastases was undertaken. Consecutive liver resections were performed from 1996 to 2006 in one centre by a single surgeon (NDK). Fourteen of these patients had combined liver resection and ileostomy closure. Case-matched analysis was undertaken. Results. Six (2.2%) patients died in the hepatectomy only group and none died in the combined group. There was no difference in operative blood loss between the two groups (0.09). Perioperative morbidity was 36% in the combined group and 23% in the hepatectomy alone group (P = 0.33). Mean hospital stay was 14 days in the combined group and 11 days in the hepatectomy only group (P = 0.046). Case-matched analysis showed a significant increase in hospital stay (P = 0.03) and complications (P = 0.049) in the combined group. Conclusion. In patients with CRLM, combined liver resection and closure of ileostomy may be associated with a higher operative morbidity and a prolonged hospital stay. PMID:19096524
Parikh, Punam P; Tashiro, Jun; Wagenaar, Amy E; Curbelo, Miosotys; Perez, Eduardo A; Neville, Holly L; Hogan, Anthony R; Sola, Juan E
2018-04-01
Appendiceal ligation during pediatric laparoscopic appendectomy (LA) may be performed using looped suture versus stapler. Controversy regarding the utility of either method exists. Clinical outcomes and cost analysis of LA with both methods were compared. All pediatric LA were performed from fiscal years 2013 and 2014 by two pediatric surgeons. While one surgeon used looped suture, the other used stapler exclusively. chi-Square tests were performed to analyze associations. Two hundred thirty-eight cases were analyzed where looped suture versus stapler LA was performed in 46% and 54% of patients, respectively. Operating room costs were $317.10 and $707.12/person for looped suture and stapler LA, respectively (P<0.0001). Difference in cost of $390.02/person was attributed solely to ligation type. On bivariate analysis, rate of in-hospital complications, length of stay, return-to-ER and readmission within 30 days did not significantly differ between groups. A comparative analysis of looped suture versus stapler device during LA for pediatric appendicitis revealed that postoperative complications, length of stay, ER visits and readmissions were not significantly different. Looped suture LA was significantly more cost efficient than stapler LA. In pediatric appendicitis, appendiceal ligation during LA may be performed safely and cost effectively with looped suture versus stapler. Cost effectiveness LEVEL OF EVIDENCE: III. Copyright © 2017 Elsevier Inc. All rights reserved.
Mitochondrial D-loop sequence of domesticated waterfowl in Central Java: goose and muscovy duck
NASA Astrophysics Data System (ADS)
Susanti, R.; Iswari, R. S.
2018-03-01
This study aims to determine the genetic characterization of domesticated waterfowl (goose and Muscovy duck) in Central Java based on a D-loop mtDNA gene. The D-loop gene was amplified using PCR technique by specific primer and sequenced using dideoxy termination method. Multiple alignments of D-loop gene obtained were 710 nucleotides at position 74 to 783 at the 5’ end (for goose) and 712 nucleotides at position 48 to 759 at the 5’ end (for Muscovy duck). The results of the polymorphism analysis on D-loop sequences of muscovy duck produced 3 haplotypes. In the D-loop gene of goose does not show polymorphism, with substitution at G117A. Phylogenetic trees reconstructions of goose and Muscovy duck, which was collected during this research compared with another species from Anser, Chairina and Anas was generated 2 forms of clusters. The first group consists of all kind of Muscovy duck together with Chairina moschata and Anas, while the second group consists of all geese and Anser cygnoides the other. The determination of Muscovy duck and geese identity can be distinguished from the genetic marker information. Based on the phylogenetic analysis, it can be concluded that the Muscovy duck is closely related to Chairina moschata, while geese is closely related to Anser cygnoides.
Shashidhar, Nagam Reddy; Reddy, S Rama Koteswara; Rachala, Madhukar Reddy
2016-06-01
Molar distalization is the non extraction method of managing Class II malocclusions. The purpose of this study was to evaluate the skeletal and dentoalveolar effects of maxillary molar distalization with K-loop appliance, and to compare these effects with that of pendulum group. Class I and dental Class II malocclusions were divided into two groups of 15 each: In Group 1 (nine females and six males; mean age, 16.0±2.6 years) patients were treated with K-Loop molar distalization supported palatally by Nance button, while in Group 2 (seven females and eight males; mean age, 15.4±4.7 years), the patients were treated with conventional pendulum appliance. Standardized lateral cephalograms were taken at the beginning of treatment (T0) and at the end of molar distalization (T1) and the changes were statistically analyzed with paired t-test. The results showed no statistically significant difference in the amount of molar distalization in either of the appliance groups: the mean amount of molar distal movement of 5.1±0.8 mm and 4.93±1.68 mm was observed in the Group 1 and 2 respectively. The incisors moved mesially by 1.3±0.63 mm in Group 1 and 1.57±0.58 mm in Group 2. K-Loop molar distalizing appliance has similar skeletal and dentoalveolar effects as that of pendulum appliance, with the advantages of simple yet efficient to control the moment-force ratio to produce all types of tooth movements and also requires minimal patient co-operation.
Dyal, Jonathan; Akampurira, Andrew; Rhein, Joshua; Morawski, Bozena M; Kiggundu, Reuben; Nabeta, Henry W; Musubire, Abdu K; Bahr, Nathan C; Williams, Darlisha A; Bicanic, Tihana; Larsen, Robert A; Meya, David B; Boulware, David R
2016-05-01
Quantitative cerebrospinal fluid (CSF) cultures provide a measure of disease severity in cryptococcal meningitis. The fungal clearance rate by quantitative cultures has become a primary endpoint for phase II clinical trials. This study determined the inter-assay accuracy of three different quantitative culture methodologies. Among 91 participants with meningitis symptoms in Kampala, Uganda, during August-November 2013, 305 CSF samples were prospectively collected from patients at multiple time points during treatment. Samples were simultaneously cultured by three methods: (1) St. George's 100 mcl input volume of CSF with five 1:10 serial dilutions, (2) AIDS Clinical Trials Group (ACTG) method using 1000, 100, 10 mcl input volumes, and two 1:100 dilutions with 100 and 10 mcl input volume per dilution on seven agar plates; and (3) 10 mcl calibrated loop of undiluted and 1:100 diluted CSF (loop). Quantitative culture values did not statistically differ between St. George-ACTG methods (P= .09) but did for St. George-10 mcl loop (P< .001). Repeated measures pairwise correlation between any of the methods was high (r≥0.88). For detecting sterility, the ACTG-method had the highest negative predictive value of 97% (91% St. George, 60% loop), but the ACTG-method had occasional (∼10%) difficulties in quantification due to colony clumping. For CSF clearance rate, St. George-ACTG methods did not differ overall (mean -0.05 ± 0.07 log10CFU/ml/day;P= .14) on a group level; however, individual-level clearance varied. The St. George and ACTG quantitative CSF culture methods produced comparable but not identical results. Quantitative cultures can inform treatment management strategies. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Roe, S C
1997-01-01
Evaluate the mechanical properties of twist, loop, double loop, double-wrap and loop/twist cerclage. The initial tension generated by 18 cerclage of each type was determined using a materials testing machine after tying around a testing jig. Six wires from each type were distracted and the initial stiffness and yield load were determined. Yield behavior was further investigated in six wires of each type by determining the load required to reduce cerclage tension below 30 Newton (N) following and incremental (50 N) stepwise load and unload regimen. The amount of collapse of the simulated bone fragments that resulted in the reduction of initial tension to 30 N was measured for the final six wires of each group. Data were analyzed by analysis of variance and a multiple comparison test. Twist type cerclage generated less tension than loop-type cerclage. The yield load of these two types was similar. Double-loop and double-wrap cerclage generated superior tension and resisted a greater load before loosening. Loop/twist cerclage had an intermediate initial tension but had the greatest resistance to loading. In the collapse test, the greater the initial tension, the more collapse could occur before the wire was loose. For all types of cerclage wire fixation, a reduction of diameter of the testing jig of more than 1% caused loosening. Double-loop and double-wrap cerclage provide greater compression of fragments and resist loads associated with weight-bearing better than the twist and loop methods. Loop/twist cerclage may have advantages because of their superior resistance to loading. All cerclage will loosen if fracture fragments collapse.
Khan, Haseeb A; Arif, Ibrahim A; Bahkali, Ali H; Al Farhan, Ahmad H; Al Homaidan, Ali A
2008-10-06
This investigation was aimed to compare the inference of antelope phylogenies resulting from the 16S rRNA, cytochrome-b (cyt-b) and d-loop segments of mitochondrial DNA using three different computational models including Bayesian (BA), maximum parsimony (MP) and unweighted pair group method with arithmetic mean (UPGMA). The respective nucleotide sequences of three Oryx species (Oryx leucoryx, Oryx dammah and Oryx gazella) and an out-group (Addax nasomaculatus) were aligned and subjected to BA, MP and UPGMA models for comparing the topologies of respective phylogenetic trees. The 16S rRNA region possessed the highest frequency of conserved sequences (97.65%) followed by cyt-b (94.22%) and d-loop (87.29%). There were few transitions (2.35%) and none transversions in 16S rRNA as compared to cyt-b (5.61% transitions and 0.17% transversions) and d-loop (11.57% transitions and 1.14% transversions) while comparing the four taxa. All the three mitochondrial segments clearly differentiated the genus Addax from Oryx using the BA or UPGMA models. The topologies of all the gamma-corrected Bayesian trees were identical irrespective of the marker type. The UPGMA trees resulting from 16S rRNA and d-loop sequences were also identical (Oryx dammah grouped with Oryx leucoryx) to Bayesian trees except that the UPGMA tree based on cyt-b showed a slightly different phylogeny (Oryx dammah grouped with Oryx gazella) with a low bootstrap support. However, the MP model failed to differentiate the genus Addax from Oryx. These findings demonstrate the efficiency and robustness of BA and UPGMA methods for phylogenetic analysis of antelopes using mitochondrial markers.
Khan, Haseeb A.; Arif, Ibrahim A.; Bahkali, Ali H.; Al Farhan, Ahmad H.; Al Homaidan, Ali A.
2008-01-01
This investigation was aimed to compare the inference of antelope phylogenies resulting from the 16S rRNA, cytochrome-b (cyt-b) and d-loop segments of mitochondrial DNA using three different computational models including Bayesian (BA), maximum parsimony (MP) and unweighted pair group method with arithmetic mean (UPGMA). The respective nucleotide sequences of three Oryx species (Oryx leucoryx, Oryx dammah and Oryx gazella) and an out-group (Addax nasomaculatus) were aligned and subjected to BA, MP and UPGMA models for comparing the topologies of respective phylogenetic trees. The 16S rRNA region possessed the highest frequency of conserved sequences (97.65%) followed by cyt-b (94.22%) and d-loop (87.29%). There were few transitions (2.35%) and none transversions in 16S rRNA as compared to cyt-b (5.61% transitions and 0.17% transversions) and d-loop (11.57% transitions and 1.14% transversions) while comparing the four taxa. All the three mitochondrial segments clearly differentiated the genus Addax from Oryx using the BA or UPGMA models. The topologies of all the gamma-corrected Bayesian trees were identical irrespective of the marker type. The UPGMA trees resulting from 16S rRNA and d-loop sequences were also identical (Oryx dammah grouped with Oryx leucoryx) to Bayesian trees except that the UPGMA tree based on cyt-b showed a slightly different phylogeny (Oryx dammah grouped with Oryx gazella) with a low bootstrap support. However, the MP model failed to differentiate the genus Addax from Oryx. These findings demonstrate the efficiency and robustness of BA and UPGMA methods for phylogenetic analysis of antelopes using mitochondrial markers. PMID:19204824
One-loop β-function for an infinite-parameter family of gauge theories
NASA Astrophysics Data System (ADS)
Krasnov, Kirill
2015-03-01
We continue to study an infinite-parametric family of gauge theories with an arbitrary function of the self-dual part of the field strength as the Lagrangian. The arising one-loop divergences are computed using the background field method. We show that they can all be absorbed by a local redefinition of the gauge field, as well as multiplicative renormalisations of the couplings. Thus, this family of theories is one-loop renormalisable. The infinite set of β-functions for the couplings is compactly stored in a renormalisation group flow for a single function of the curvature. The flow is obtained explicitly.
Massless spectra and gauge couplings at one-loop on non-factorisable toroidal orientifolds
NASA Astrophysics Data System (ADS)
Berasaluce-González, Mikel; Honecker, Gabriele; Seifert, Alexander
2018-01-01
So-called 'non-factorisable' toroidal orbifolds can be rewritten in a factorised form as a product of three two-tori by imposing an additional shift symmetry. This finding of Blaszczyk et al. [1] provides a new avenue to Conformal Field Theory methods, by which the vector-like massless matter spectrum - and thereby the type of gauge group enhancement on orientifold invariant fractional D6-branes - and the one-loop corrections to the gauge couplings in Type IIA orientifold theories can be computed in addition to the well-established chiral matter spectrum derived from topological intersection numbers among three-cycles. We demonstrate this framework for the Z4 × ΩR orientifolds on the A3 ×A1 ×B2-type torus. As observed before for factorisable backgrounds, also here the one-loop correction can drive the gauge groups to stronger coupling as demonstrated by means of a four-generation Pati-Salam example.
Singh, Shiva; Khurana, Alkesh Kumar; Harode, Hemant Ashish; Tripathi, Apoorva; Pakhare, Abhijit; Chaware, Prashant
2016-01-01
Background: Dermatoglyphics and bronchial asthma (BA) are both influenced by genetic factors. Hence, we assessed the diagnostic potential of correlation between fingerprint pattern and BA. Materials and Methods: The study was carried out in out-patient Department of Pulmonary Medicine of All India Institute of Medical Sciences Bhopal. It included 36 patients of BA and 50 nonasthmatic individuals as controls. The following parameters were studied and analyzed: (a) Whorls, (b) arches, (c) radial loops, (d) ulnar loops, (e) the absolute finger ridge count (AFRC), (f) total finger ridge count (TFRC). Results: A significant decrease in the mean value of the arches and increase in the mean value of the ulnar loops were observed in BA patients compared to the control group. The mean values of TFRC, AFRC, and whorls were similar in both groups. Conclusion: Evaluation of dermatoglyphic patterns may be useful in identifying patients prone to developing BA. PMID:27003968
Yamunadevi, Andamuthu; Dineshshankar, Janardhanam; Banu, Safeena; Fathima, Nilofar; Ganapathy; Yoithapprabhunath, Thukanayakanpalayam Ragunathan; Maheswaran, Thangadurai; Ilayaraja, Vadivel
2015-01-01
Background: Dermatoglyphic patterns, which are regularly used in judicial and legal investigations, can be valuable in the diagnosis of many diseases associated with genetic disorders. Dental caries although of infectious origin, may have a genetic predisposition. Hence, we evaluated the correlation between dental caries and dermatoglyphic patterns among subjects with and without dental caries and evaluated its association with environmental factors such as salivary pH. Materials and Methods: Totally, 76 female students within the age group of 18-23 years were clinically examined, and their decayed, missing, filled teeth (DMFT) score and oral hygiene index-simplified were recorded. Based on their DMFT score, they were divided into following three groups; group I (n = 16, DMFT score = 0), group II (n = 30, DMFT score <5), and group III (n = 30, DMFT score ≥5). Their fingerprint patterns and salivary pH were recorded and analyzed using descriptive statistics. Results: Dermatoglyphic pattern distribution in caries-free group showed more ulnar loops than high caries group (group III) while high caries group showed more whorl patterns. Presence of whorl with double loop, whorl within a loop was associated with high DMFT score. The total finger ridge count was lower in caries group. The mean salivary pH was higher in caries-free group than high caries group. Thus, we conclude that dermatoglyphic patterns may be potential diagnostic tool for detecting patients prone to develop dental caries. PMID:26283816
Inam, Azhar; Adamowski, Jan; Halbe, Johannes; Prasher, Shiv
2015-04-01
Over the course of the last twenty years, participatory modeling has increasingly been advocated as an integral component of integrated, adaptive, and collaborative water resources management. However, issues of high cost, time, and expertise are significant hurdles to the widespread adoption of participatory modeling in many developing countries. In this study, a step-wise method to initialize the involvement of key stakeholders in the development of qualitative system dynamics models (i.e. causal loop diagrams) is presented. The proposed approach is designed to overcome the challenges of low expertise, time and financial resources that have hampered previous participatory modeling efforts in developing countries. The methodological framework was applied in a case study of soil salinity management in the Rechna Doab region of Pakistan, with a focus on the application of qualitative modeling through stakeholder-built causal loop diagrams to address soil salinity problems in the basin. Individual causal loop diagrams were developed by key stakeholder groups, following which an overall group causal loop diagram of the entire system was built based on the individual causal loop diagrams to form a holistic qualitative model of the whole system. The case study demonstrates the usefulness of the proposed approach, based on using causal loop diagrams in initiating stakeholder involvement in the participatory model building process. In addition, the results point to social-economic aspects of soil salinity that have not been considered by other modeling studies to date. Copyright © 2015 Elsevier Ltd. All rights reserved.
Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Vega-Estrada, Alfredo
2013-04-01
To compare the visual and intraocular optical quality outcomes with different designs of the refractive rotationally asymmetric multifocal intraocular lens (MFIOL) (Lentis Mplus; Oculentis GmbH, Berlin, Germany) with or without capsular tension ring (CTR) implantation. One hundred thirty-five consecutive eyes of 78 patients with cataract (ages 36 to 82 years) were divided into three groups: 43 eyes implanted with the C-Loop haptic design without CTR (C-Loop haptic only group); 47 eyes implanted with the C-Loop haptic design with CTR (C-Loop haptic with CTR group); and 45 eyes implanted with the plate-haptic design (plate-haptic group). Visual acuity, contrast sensitivity, defocus curve, and ocular and intraocular optical quality were evaluated at 3 months postoperatively. Significant differences in the postoperative sphere were found (P = .01), with a more myopic postoperative refraction for the C-Loop haptic only group. No significant differences were detected in photopic and scotopic contrast sensitivity among groups (P ⩾ .05). Significantly better visual acuities were present in the C-Loop haptic with CTR group for the defocus levels of -2.0, -1.5, -1.0, and -0.50 D (P ⩽.03). Statistically significant differences among groups were found in total intraocular root mean square (RMS), high-order intraocular RMS, and intraocular coma-like RMS aberrations (P ⩽.04), with lower values from the plate-haptic group. The plate-haptic design and the C-Loop haptic design with CTR implantation both allow good visual rehabilitation. However, better refractive predictability and intraocular optical quality was obtained with the plate-haptic design without CTR implantation. The plate-haptic design seems to be a better design to support rotational asymmetric MFIOL optics. Copyright 2013, SLACK Incorporated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Titov, Eugene; Lustbader, Jason; Leighton, Daniel
The National Renewable Energy Laboratory's (NREL's) CoolSim MATLAB/Simulink modeling framework was extended by including a newly developed coolant loop solution method aimed at reducing the simulation effort for arbitrarily complex thermal management systems. The new approach does not require the user to identify specific coolant loops and their flow. The user only needs to connect the fluid network elements in a manner consistent with the desired schematic. Using the new solution method, a model of NREL's advanced combined coolant loop system for electric vehicles was created that reflected the test system architecture. This system was built using components provided bymore » the MAHLE Group and included both air conditioning and heat pump modes. Validation with test bench data and verification with the previous solution method were performed for 10 operating points spanning a range of ambient temperatures between -2 degrees C and 43 degrees C. The largest root mean square difference between pressure, temperature, energy and mass flow rate data and simulation results was less than 7%.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Titov, Gene; Lustbader, Jason; Leighton, Daniel
The National Renewable Energy Laboratory's (NREL's) CoolSim MATLAB/Simulink modeling framework was extended by including a newly developed coolant loop solution method aimed at reducing the simulation effort for arbitrarily complex thermal management systems. The new approach does not require the user to identify specific coolant loops and their flow. The user only needs to connect the fluid network elements in a manner consistent with the desired schematic. Using the new solution method, a model of NREL's advanced combined coolant loop system for electric vehicles was created that reflected the test system architecture. This system was built using components provided bymore » the MAHLE Group and included both air conditioning and heat pump modes. Validation with test bench data and verification with the previous solution method were performed for 10 operating points spanning a range of ambient temperatures between -2 degrees C and 43 degrees C. The largest root mean square difference between pressure, temperature, energy and mass flow rate data and simulation results was less than 7%.« less
Automated classification of RNA 3D motifs and the RNA 3D Motif Atlas
Petrov, Anton I.; Zirbel, Craig L.; Leontis, Neocles B.
2013-01-01
The analysis of atomic-resolution RNA three-dimensional (3D) structures reveals that many internal and hairpin loops are modular, recurrent, and structured by conserved non-Watson–Crick base pairs. Structurally similar loops define RNA 3D motifs that are conserved in homologous RNA molecules, but can also occur at nonhomologous sites in diverse RNAs, and which often vary in sequence. To further our understanding of RNA motif structure and sequence variability and to provide a useful resource for structure modeling and prediction, we present a new method for automated classification of internal and hairpin loop RNA 3D motifs and a new online database called the RNA 3D Motif Atlas. To classify the motif instances, a representative set of internal and hairpin loops is automatically extracted from a nonredundant list of RNA-containing PDB files. Their structures are compared geometrically, all-against-all, using the FR3D program suite. The loops are clustered into motif groups, taking into account geometric similarity and structural annotations and making allowance for a variable number of bulged bases. The automated procedure that we have implemented identifies all hairpin and internal loop motifs previously described in the literature. All motif instances and motif groups are assigned unique and stable identifiers and are made available in the RNA 3D Motif Atlas (http://rna.bgsu.edu/motifs), which is automatically updated every four weeks. The RNA 3D Motif Atlas provides an interactive user interface for exploring motif diversity and tools for programmatic data access. PMID:23970545
2PI effective theory at next-to-leading order using the functional renormalization group
NASA Astrophysics Data System (ADS)
Carrington, M. E.; Friesen, S. A.; Meggison, B. A.; Phillips, C. D.; Pickering, D.; Sohrabi, K.
2018-02-01
We consider a symmetric scalar theory with quartic coupling in four dimensions. We show that the four-loop 2PI calculation can be done using a renormalization group method. The calculation involves one bare coupling constant which is introduced at the level of the Lagrangian and is therefore conceptually simpler than a standard 2PI calculation, which requires multiple counterterms. We explain how our method can be used to do the corresponding calculation at the 4PI level, which cannot be done using any known method by introducing counterterms.
PyR@TE. Renormalization group equations for general gauge theories
NASA Astrophysics Data System (ADS)
Lyonnet, F.; Schienbein, I.; Staub, F.; Wingerter, A.
2014-03-01
Although the two-loop renormalization group equations for a general gauge field theory have been known for quite some time, deriving them for specific models has often been difficult in practice. This is mainly due to the fact that, albeit straightforward, the involved calculations are quite long, tedious and prone to error. The present work is an attempt to facilitate the practical use of the renormalization group equations in model building. To that end, we have developed two completely independent sets of programs written in Python and Mathematica, respectively. The Mathematica scripts will be part of an upcoming release of SARAH 4. The present article describes the collection of Python routines that we dubbed PyR@TE which is an acronym for “Python Renormalization group equations At Two-loop for Everyone”. In PyR@TE, once the user specifies the gauge group and the particle content of the model, the routines automatically generate the full two-loop renormalization group equations for all (dimensionless and dimensionful) parameters. The results can optionally be exported to LaTeX and Mathematica, or stored in a Python data structure for further processing by other programs. For ease of use, we have implemented an interactive mode for PyR@TE in form of an IPython Notebook. As a first application, we have generated with PyR@TE the renormalization group equations for several non-supersymmetric extensions of the Standard Model and found some discrepancies with the existing literature. Catalogue identifier: AERV_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AERV_v1_0.html Program obtainable from: CPC Program Library, Queen’s University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 924959 No. of bytes in distributed program, including test data, etc.: 495197 Distribution format: tar.gz Programming language: Python. Computer: Personal computer. Operating system: Tested on Fedora 15, MacOS 10 and 11, Ubuntu 12. Classification: 11.1. External routines: SymPy, PyYAML, NumPy, IPython, SciPy Nature of problem: Deriving the renormalization group equations for a general quantum field theory. Solution method: Group theory, tensor algebra Running time: Tens of seconds per model (one-loop), tens of minutes (two-loop)
Han, Nanyu; Mu, Yuguang
2013-01-01
Neuraminidase (NA) of influenza is a key target for antiviral inhibitors, and the 150-cavity in group-1 NA provides new insight in treating this disease. However, NA of 2009 pandemic influenza (09N1) was found lacking this cavity in a crystal structure. To address the issue of flexibility of the 150-loop, Hamiltonian replica exchange molecular dynamics simulations were performed on different groups of NAs. Free energy landscape calculated based on the volume of 150-cavity indicates that 09N1 prefers open forms of 150-loop. The turn A (residues 147-150) of the 150-loop is discovered as the most dynamical motif which induces the inter-conversion of this loop among different conformations. In the turn A, the backbone dynamic of residue 149 is highly related with the shape of 150-loop, thus can function as a marker for the conformation of 150-loop. As a contrast, the closed conformation of 150-loop is more energetically favorable in N2, one of group-2 NAs. The D147-H150 salt bridge is found having no correlation with the conformation of 150-loop. Instead the intimate salt bridge interaction between the 150 and 430 loops in N2 variant contributes the stabilizing factor for the closed form of 150-loop. The clustering analysis elaborates the structural plasticity of the loop. This enhanced sampling simulation provides more information in further structural-based drug discovery on influenza virus.
Han, Nanyu; Mu, Yuguang
2013-01-01
Neuraminidase (NA) of influenza is a key target for antiviral inhibitors, and the 150-cavity in group-1 NA provides new insight in treating this disease. However, NA of 2009 pandemic influenza (09N1) was found lacking this cavity in a crystal structure. To address the issue of flexibility of the 150-loop, Hamiltonian replica exchange molecular dynamics simulations were performed on different groups of NAs. Free energy landscape calculated based on the volume of 150-cavity indicates that 09N1 prefers open forms of 150-loop. The turn A (residues 147–150) of the 150-loop is discovered as the most dynamical motif which induces the inter-conversion of this loop among different conformations. In the turn A, the backbone dynamic of residue 149 is highly related with the shape of 150-loop, thus can function as a marker for the conformation of 150-loop. As a contrast, the closed conformation of 150-loop is more energetically favorable in N2, one of group-2 NAs. The D147-H150 salt bridge is found having no correlation with the conformation of 150-loop. Instead the intimate salt bridge interaction between the 150 and 430 loops in N2 variant contributes the stabilizing factor for the closed form of 150-loop. The clustering analysis elaborates the structural plasticity of the loop. This enhanced sampling simulation provides more information in further structural-based drug discovery on influenza virus. PMID:23593372
Cool transition region loops observed by the Interface Region Imaging Spectrograph
NASA Astrophysics Data System (ADS)
Huang, Z.; Xia, L.; Li, B.; Madjarska, M. S.
2015-12-01
An important class of loops in the solar atmosphere, cool transition region loops, have received little attention mainly due to instrumental limitations. We analyze a cluster of these loops in the on-disk active region NOAA 11934 recorded in a Si IV 1402.8 Å spectral raster and 1400Å slit-jaw (SJ) images taken by the Interface Region Imaging Spectrograph. We divide these loops into three groups and study their dynamics, evolution and interaction.The first group comprises geometrically relatively stable loops, which are finely scaled with 382~626 km cross-sections. Siphon flows in these loops are suggested by the Doppler velocities gradually changing from -10 km/s (blue-shifts) in one end to 20 km/s (red-shifts) in the other. Nonthermal velocities from 15 to 25 km/s were determined. The obtained physical properties suggest that these loops are impulsively heated by magnetic reconnection occurring at the blue-shifted footpoints where magnetic cancellation with a rate of 1015 Mx/s is found. The released magnetic energy is redistributed by the siphon flows. The second group corresponds to two active footpoints rooted in mixed-magnetic-polarity regions. Magnetic reconnection in both footpoints is suggested by explosive-event line profiles with enhanced wings up to 200 km/s and magnetic cancellation with a rate of ~1015 Mx/s. In the third group, an interaction between two cool loop systems is observed. Mixed-magnetic polarities are seen in their conjunction area where explosive-event line profiles and magnetic cancellation with a rate of 3×1015 Mx/s are found. This is a clear indication that magnetic reconnection occurs between these two loop systems. Our observations suggest that the cool transition region loops are heated impulsively most likely by sequences of magnetic reconnection events.
Cool Transition Region Loops Observed by the Interface Region Imaging Spectrograph
NASA Astrophysics Data System (ADS)
Huang, Zhenghua; Xia, Lidong; Li, Bo; Madjarska, Maria S.
2015-09-01
We report on the first Interface Region Imaging Spectrograph (IRIS) study of cool transition region loops, a class of loops that has received little attention in the literature. A cluster of such loops was observed on the solar disk in active region NOAA11934, in the Si iv 1402.8 Å spectral raster and 1400 Å slit-jaw images. We divide the loops into three groups and study their dynamics. The first group comprises relatively stable loops, with 382-626 km cross-sections. Observed Doppler velocities are suggestive of siphon flows, gradually changing from -10 km s-1 at one end to 20 km s-1 at the other end of the loops. Nonthermal velocities of 15 ˜ 25 km s-1 were determined. Magnetic cancellation with a rate of 1015 Mx s-1 is found at the blueshifted footpoints. These physical properties suggest that these loops are impulsively heated by magnetic reconnection, and the siphon flows play an important role in the energy redistribution. The second group corresponds to two footpoints rooted in mixed-magnetic-polarity regions, where magnetic cancellation with a rate of 1015 Mx s-1 and explosive-event line profiles with enhanced wings of up to 200 km s-1 were observed. In the third group, interaction between two cool loop systems is observed. Evidence for magnetic reconnection between the two loop systems is reflected in the explosive-event line profiles and magnetic cancellation with a rate of 3× {10}15 Mx s-1 observed in the corresponding area. The IRIS has provided opportunity for in-depth investigations of cool transition region loops. Further numerical experiments are crucial for understanding their physics and their roles in the coronal heating processes.
Run-time parallelization and scheduling of loops
NASA Technical Reports Server (NTRS)
Saltz, Joel H.; Mirchandaney, Ravi; Crowley, Kay
1991-01-01
Run-time methods are studied to automatically parallelize and schedule iterations of a do loop in certain cases where compile-time information is inadequate. The methods presented involve execution time preprocessing of the loop. At compile-time, these methods set up the framework for performing a loop dependency analysis. At run-time, wavefronts of concurrently executable loop iterations are identified. Using this wavefront information, loop iterations are reordered for increased parallelism. Symbolic transformation rules are used to produce: inspector procedures that perform execution time preprocessing, and executors or transformed versions of source code loop structures. These transformed loop structures carry out the calculations planned in the inspector procedures. Performance results are presented from experiments conducted on the Encore Multimax. These results illustrate that run-time reordering of loop indexes can have a significant impact on performance.
Hardware-in-the-Loop Rendezvous Tests of a Novel Actuators Command Concept
NASA Astrophysics Data System (ADS)
Gomes dos Santos, Willer; Marconi Rocco, Evandro; Boge, Toralf; Benninghoff, Heike; Rems, Florian
2016-12-01
Integration, test and validation results, in a real-time environment, of a novel concept for spacecraft control are presented in this paper. The proposed method commands simultaneously a group of actuators optimizing a given set of objective functions based on a multiobjective optimization technique. Since close proximity maneuvers play an important role in orbital servicing missions, the entire GNC system has been integrated and tested at a hardware-in-the-loop (HIL) rendezvous and docking simulator known as European Proximity Operations Simulator (EPOS). During the test campaign at EPOS facility, a visual camera has been used to provide the necessary measurements for calculating the relative position with respect to the target satellite during closed-loop simulations. In addition, two different configurations of spacecraft control have been considered in this paper: a thruster reaction control system and a mixed actuators mode which includes thrusters, reaction wheels, and magnetic torqrods. At EPOS, results of HIL closed-loop tests have demonstrated that a safe and stable rendezvous approach can be achieved with the proposed GNC loop.
Lin, Jin-Ching; Wang, Chen-Chi; Jiang, Rong-San; Wang, Wen-Yi; Liu, Shih-An
2015-01-01
Objectives The aim of this study was to investigate somatic mutations in the D-loop of mitochondrial DNA (mtDNA) and their impact on survival in oral squamous cell carcinoma patients. Materials and Methods Surgical specimen confirmed by pathological examination and corresponding non-cancerous tissues were collected from 120 oral squamous cell carcinoma patients. The sequence in the D-loop of mtDNA from non-cancerous tissues was compared with that from paired cancer samples and any sequence differences were recognized as somatic mutations. Results Somatic mutations in the D-loop of mtDNA were identified in 75 (62.5%) oral squamous cell carcinoma patients and most of them occurred in the poly-C tract. Although there were no significant differences in demographic and tumor-related features between participants with and without somatic mutation, the mutation group had a better survival rate (5 year disease-specific survival rate: 64.0% vs. 43.0%, P = 0.0266). Conclusion Somatic mutation in D-loop of mtDNA was associated with a better survival in oral squamous cell carcinoma patients. PMID:25906372
Fingerprints: A simple method for Screening Hemophilic Patients.
Jamalian, M; Mesri, M; Vishteh, H R K; Solhi, H; Salehpour, R
2014-08-01
The present study aims to compare hemophilic patients' fingerprint types with the normal people to help diagnose the disease, particularly new occurrences of the disease. This case-control study was conducted in 2012. Sixty two patients with hemophilia type A and 62 normal healthy people were selected. The type of fingerprint was determined by a forensic specialist who was kept unaware of the participants' group. Using advanced Henry method, the main types of fingerprints were classified as arch, loop, whorl, as well as other types. In the control group, loop type (65%) and in the case group the whorl type (34%) were the most frequent fingerprint type (p < 0.001) and there was a significant difference of fingerprint in each finger between two groups. In addition, the average number of whorl type in the patients with mild disease was significantly higher and the average number of arch and other types of fingerprints was significantly lower than patients with moderate or severe disease. The findings of the present study indicated that not only are the fingerprints of normal and hemophilic people different, but also a difference was observed between hemophilic patients with the mild factor level and patients with moderate or severe one.
Qualitative Analysis of Primary Fingerprint Pattern in Different Blood Group and Gender in Nepalese
Maharjan, Niroj; Adhikari, Nischita; Shrestha, Pragya
2018-01-01
Dermatoglyphics, the study of epidermal ridges on palm, sole, and digits, is considered as most effective and reliable evidence of identification. The fingerprints were studied in 300 Nepalese of known blood groups of different ages and classified into primary patterns and then analyzed statistically. In both sexes, incidence of loops was highest in ABO blood group and Rh +ve blood types, followed by whorls and arches, while the incidence of whorls was highest followed by loops and arches in Rh −ve blood types. Loops were higher in all blood groups except “A –ve” and “B –ve” where whorls were predominant. The fingerprint pattern in Rh blood types of blood group “A” was statistically significant while in others it was insignificant. In middle and little finger, loops were higher whereas in ring finger whorls were higher in all blood groups. Whorls were higher in thumb and index finger except in blood group “O” where loops were predominant. This study concludes that distribution of primary pattern of fingerprint is not related to gender and blood group but is related to individual digits. PMID:29593909
Lin, Giant C; Freitag, Suzanne K; Kocharyan, Armine; Yoon, Michael K; Lefebvre, Daniel R; Bleier, Benjamin S
2016-05-01
The medial rectus muscle (MRM) is the medial boundary to the intraconal space of the orbit, and retraction of the MRM is oftentimes necessary for endoscopic removal of intraconal tumors, e.g., orbital hemangioma. We evaluated each of the reported methods of MRM retraction for endoscopic orbital surgery and quantified the degree of intraconal exposure conferred by each method. Eight orbits from four cadaver heads were dissected. In each orbit, medial orbital decompression was performed and the MRM was retracted by using four previously described techniques: (1) external MRM retraction at the globe insertion point by using vessel loop (external group), (2) transseptal MRM retraction by using vessel loop (transseptal group), (3) transchoanal retraction of the MRM by using vessel loop (choanal group), and (4) transseptal four-handed technique by using double ball retraction by a second surgeon (transseptal double ball group). The length, height, and area of exposure of the medial intraconal space were quantified and compared. The average ± standard deviation (SD) anterior-posterior exposures for the external group, transseptal group, and transseptal double ball group were 17.51 ± 3.39 mm, 16.59 ± 4.16 mm, and 18.0 ± 15.25 mm, respectively. The choanal group provided significantly less exposure (12.39 ± 3.44 mm, p = 0.049) than the other groups. The average ± SD vertical exposures for the transseptal group, choanal group, and transseptal double ball group were 12.53 ± 4.38 mm, 13.05 ± 5.86 mm, and 13.57 ± 3.74 mm, respectively. The external group provided significantly less exposure (4.51 ± 1.56 mm, p = 0.0072) than the other groups. The transseptal and transseptal double ball groups provided the greatest total access by surface area (58.88 ± 26.96 mm(2) and 62.94 ± 34.74 mm(2), respectively) compared with the external and choanal groups (34.82 ± 23.37 mm(2) and 43.10 ± 23.68 mm(2), respectively). Although the transseptal trajectory of MRM retraction was optimal, the difference in total area of exposure between the static vessel loop retraction and the dynamic, four-handed technique with double ball instrument retraction was not significant. Of note, the exposure provided by the choanal technique required the surgeon to work both above and below the muscle. Retraction of the MRM toward the choanae provided the least length of exposure, and external retraction exposed the least height and total area. Transseptal MRM retraction was most favorable and provided the largest endoscopic corridor to the medial intraconal space. A four-handed approach for endoscopic intraconal surgery of the orbit may offer advantages in dynamic adjustments in retraction.
Run-time parallelization and scheduling of loops
NASA Technical Reports Server (NTRS)
Saltz, Joel H.; Mirchandaney, Ravi; Crowley, Kay
1990-01-01
Run time methods are studied to automatically parallelize and schedule iterations of a do loop in certain cases, where compile-time information is inadequate. The methods presented involve execution time preprocessing of the loop. At compile-time, these methods set up the framework for performing a loop dependency analysis. At run time, wave fronts of concurrently executable loop iterations are identified. Using this wavefront information, loop iterations are reordered for increased parallelism. Symbolic transformation rules are used to produce: inspector procedures that perform execution time preprocessing and executors or transformed versions of source code loop structures. These transformed loop structures carry out the calculations planned in the inspector procedures. Performance results are presented from experiments conducted on the Encore Multimax. These results illustrate that run time reordering of loop indices can have a significant impact on performance. Furthermore, the overheads associated with this type of reordering are amortized when the loop is executed several times with the same dependency structure.
Lilot, Marc; Bellon, Amandine; Gueugnon, Marine; Laplace, Marie-Christine; Baffeleuf, Bruno; Hacquard, Pauline; Barthomeuf, Felicie; Parent, Camille; Tran, Thomas; Soubirou, Jean-Luc; Robinson, Philip; Bouvet, Lionel; Vassal, Olivia; Lehot, Jean-Jacques; Piriou, Vincent
2018-01-27
An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical center. The closed-loop system was connected to a CO monitoring system and delivered automated colloid fluid boluses. Moderate to high-risk abdominal surgical patients were randomized either to the closed-loop or the manual group. Intraoperative final CO was the primary endpoint. Secondary endpoints were intraoperative overall mean cardiac index (CI), increase from initial to final CI, intraoperative fluid volume and postoperative outcomes. From January 2014 to November 2015, 46 patients were randomized. There was a lower initial CI (2.06 vs. 2.51 l min -1 m -2 , p = 0.042) in the closed-loop compared to the control group. No difference in final CO and in overall mean intraoperative CI was observed between groups. A significant relative increase from initial to final CI values was observed in the closed-loop but not the control group (+ 28.6%, p = 0.006 vs. + 1.2%, p = 0.843). No difference was found for intraoperative fluid management and postoperative outcomes between groups. There was no significant impact on the primary study endpoint, but this was found in a context of unexpected lower initial CI in the closed-loop group.Trial registry number ID-RCB/EudraCT: 2013-A00770-45. ClinicalTrials.gov Identifier NCT01950845, date of registration: 17 September 2013.
Park, Hahnbeom; Lee, Gyu Rie; Heo, Lim; Seok, Chaok
2014-01-01
Protein loop modeling is a tool for predicting protein local structures of particular interest, providing opportunities for applications involving protein structure prediction and de novo protein design. Until recently, the majority of loop modeling methods have been developed and tested by reconstructing loops in frameworks of experimentally resolved structures. In many practical applications, however, the protein loops to be modeled are located in inaccurate structural environments. These include loops in model structures, low-resolution experimental structures, or experimental structures of different functional forms. Accordingly, discrepancies in the accuracy of the structural environment assumed in development of the method and that in practical applications present additional challenges to modern loop modeling methods. This study demonstrates a new strategy for employing a hybrid energy function combining physics-based and knowledge-based components to help tackle this challenge. The hybrid energy function is designed to combine the strengths of each energy component, simultaneously maintaining accurate loop structure prediction in a high-resolution framework structure and tolerating minor environmental errors in low-resolution structures. A loop modeling method based on global optimization of this new energy function is tested on loop targets situated in different levels of environmental errors, ranging from experimental structures to structures perturbed in backbone as well as side chains and template-based model structures. The new method performs comparably to force field-based approaches in loop reconstruction in crystal structures and better in loop prediction in inaccurate framework structures. This result suggests that higher-accuracy predictions would be possible for a broader range of applications. The web server for this method is available at http://galaxy.seoklab.org/loop with the PS2 option for the scoring function.
Spatially-protected Topology and Group Cohomology in Band Insulators
NASA Astrophysics Data System (ADS)
Alexandradinata, A.
This thesis investigates band topologies which rely fundamentally on spatial symmetries. A basic geometric property that distinguishes spatial symmetry regards their transformation of the spatial origin. Point groups consist of spatial transformations that preserve the spatial origin, while un-split extensions of the point groups by spatial translations are referred to as nonsymmorphic space groups. The first part of the thesis addresses topological phases with discretely-robust surface properties: we introduce theories for the Cnv point groups, as well as certain nonsymmorphic groups that involve glide reflections. These band insulators admit a powerful characterization through the geometry of quasimomentum space; parallel transport in this space is represented by the Wilson loop. The non-symmorphic topology we study is naturally described by a further extension of the nonsymmorphic space group by quasimomentum translations (the Wilson loop), thus placing real and quasimomentum space on equal footing -- here, we introduce the language of group cohomology into the theory of band insulators. The second part of the thesis addresses topological phases without surface properties -- their only known physical consequences are discrete signatures in parallel transport. We provide two such case studies with spatial-inversion and discrete-rotational symmetries respectively. One lesson learned here regards the choice of parameter loops in which we carry out transport -- the loop must be chosen to exploit the symmetry that protects the topology. While straight loops are popular for their connection with the geometric theory of polarization, we show that bent loops also have utility in topological band theory.
Cosmological perturbation theory using the FFTLog: formalism and connection to QFT loop integrals
NASA Astrophysics Data System (ADS)
Simonović, Marko; Baldauf, Tobias; Zaldarriaga, Matias; Carrasco, John Joseph; Kollmeier, Juna A.
2018-04-01
We present a new method for calculating loops in cosmological perturbation theory. This method is based on approximating a ΛCDM-like cosmology as a finite sum of complex power-law universes. The decomposition is naturally achieved using an FFTLog algorithm. For power-law cosmologies, all loop integrals are formally equivalent to loop integrals of massless quantum field theory. These integrals have analytic solutions in terms of generalized hypergeometric functions. We provide explicit formulae for the one-loop and the two-loop power spectrum and the one-loop bispectrum. A chief advantage of our approach is that the difficult part of the calculation is cosmology independent, need be done only once, and can be recycled for any relevant predictions. Evaluation of standard loop diagrams then boils down to a simple matrix multiplication. We demonstrate the promise of this method for applications to higher multiplicity/loop correlation functions.
Selectivity in ligand recognition of G-quadruplex loops.
Campbell, Nancy H; Patel, Manisha; Tofa, Amina B; Ghosh, Ragina; Parkinson, Gary N; Neidle, Stephen
2009-03-03
A series of disubstituted acridine ligands have been cocrystallized with a bimolecular DNA G-quadruplex. The ligands have a range of cyclic amino end groups of varying size. The crystal structures show that the diagonal loop in this quadruplex results in a large cavity for these groups, in contrast to the steric constraints imposed by propeller loops in human telomeric quadruplexes. We conclude that the nature of the loop has a significant influence on ligand selectivity for particular quadruplex folds.
Quantum mechanics in non-inertial reference frames: Time-dependent rotations and loop prolongations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klink, W.H., E-mail: william-klink@uiowa.edu; Wickramasekara, S., E-mail: wickrama@grinnell.edu; Department of Physics, Grinnell College, Grinnell, IA 50112
2013-09-15
This is the fourth in a series of papers on developing a formulation of quantum mechanics in non-inertial reference frames. This formulation is grounded in a class of unitary cocycle representations of what we have called the Galilean line group, the generalization of the Galilei group to include transformations amongst non-inertial reference frames. These representations show that in quantum mechanics, just as the case in classical mechanics, the transformations to accelerating reference frames give rise to fictitious forces. In previous work, we have shown that there exist representations of the Galilean line group that uphold the non-relativistic equivalence principle asmore » well as representations that violate the equivalence principle. In these previous studies, the focus was on linear accelerations. In this paper, we undertake an extension of the formulation to include rotational accelerations. We show that the incorporation of rotational accelerations requires a class of loop prolongations of the Galilean line group and their unitary cocycle representations. We recover the centrifugal and Coriolis force effects from these loop representations. Loops are more general than groups in that their multiplication law need not be associative. Hence, our broad theoretical claim is that a Galilean quantum theory that holds in arbitrary non-inertial reference frames requires going beyond groups and group representations, the well-established framework for implementing symmetry transformations in quantum mechanics. -- Highlights: •A formulation of Galilean quantum mechanics in non-inertial reference frames is presented. •The Galilei group is generalized to infinite dimensional Galilean line group. •Loop prolongations of Galilean line group contain central extensions of Galilei group. •Unitary representations of the loops are constructed. •These representations lead to terms in the Hamiltonian corresponding to fictitious forces, including centrifugal and Coriolis forces.« less
Stavropoulou, Charitini; Doherty, Carole; Tosey, Paul
2015-01-01
Context Incident-reporting systems (IRSs) are used to gather information about patient safety incidents. Despite the financial burden they imply, however, little is known about their effectiveness. This article systematically reviews the effectiveness of IRSs as a method of improving patient safety through organizational learning. Methods Our systematic literature review identified 2 groups of studies: (1) those comparing the effectiveness of IRSs with other methods of error reporting and (2) those examining the effectiveness of IRSs on settings, structures, and outcomes in regard to improving patient safety. We used thematic analysis to compare the effectiveness of IRSs with other methods and to synthesize what was effective, where, and why. Then, to assess the evidence concerning the ability of IRSs to facilitate organizational learning, we analyzed studies using the concepts of single-loop and double-loop learning. Findings In total, we identified 43 studies, 8 that compared IRSs with other methods and 35 that explored the effectiveness of IRSs on settings, structures, and outcomes. We did not find strong evidence that IRSs performed better than other methods. We did find some evidence of single-loop learning, that is, changes to clinical settings or processes as a consequence of learning from IRSs, but little evidence of either improvements in outcomes or changes in the latent managerial factors involved in error production. In addition, there was insubstantial evidence of IRSs enabling double-loop learning, that is, a cultural change or a change in mind-set. Conclusions The results indicate that IRSs could be more effective if the criteria for what counts as an incident were explicit, they were owned and led by clinical teams rather than centralized hospital departments, and they were embedded within organizations as part of wider safety programs. PMID:26626987
Cai, Wansong; Chen, Zhiyuan; Wen, Liping; Jiang, Xiangxin; Liu, Xiuheng
2016-01-01
Evaluate the efficiency and safety of bipolar plasma vaporization using plasma-cutting and plasma-loop electrodes for the treatment of posterior urethral stricture. Compare the outcomes following bipolar plasma vaporization with conventional cold-knife urethrotomy. A randomized trial was performed to compare patient outcomes from the bipolar and cold-knife groups. All patients were assessed at 6 and 12 months postoperatively via urethrography and uroflowmetry. At the end of the first postoperative year, ureteroscopy was performed to evaluate the efficacy of the procedure. The mean follow-up time was 13.9 months (range: 12 to 21 months). If re-stenosis was not identified by both urethrography and ureteroscopy, the procedure was considered "successful". Fifty-three male patients with posterior urethral strictures were selected and randomly divided into two groups: bipolar group (n=27) or cold-knife group (n=26). Patients in the bipolar group experienced a shorter operative time compared to the cold-knife group (23.45±7.64 hours vs 33.45±5.45 hours, respectively). The 12-month postoperative Qmax was faster in the bipolar group than in the cold-knife group (15.54±2.78 ml/sec vs 18.25±2.12 ml/sec, respectively). In the bipolar group, the recurrence-free rate was 81.5% at a mean follow-up time of 13.9 months. In the cold-knife group, the recurrence-free rate was 53.8%. The application of bipolar plasma-cutting and plasma-loop electrodes for the management of urethral stricture disease is a safe and reliable method that minimizes the morbidity of urethral stricture resection. The advantages include a lower recurrence rate and shorter operative time compared to the cold-knife technique.
Sasaki, Ryo; Takeuchi, Yuichi; Watanabe, Yorikatsu; Niimi, Yosuke; Sakurai, Hiroyuki; Miyata, Mariko; Yamato, Masayuki
2014-01-01
Background: Extensive facial nerve defects between the facial nerve trunk and its branches can be clinically reconstructed by incorporating double innervation into an end-to-side loop graft technique. This study developed a new animal model to evaluate the technique’s ability to promote nerve regeneration. Methods: Rats were divided into the intact, nonsupercharge, and supercharge groups. Artificially created facial nerve defects were reconstructed with a nerve graft, which was end-to-end sutured from proximal facial nerve stump to the mandibular branch (nonsupercharge group), or with the graft of which other end was end-to-side sutured to the hypoglossal nerve (supercharge group). And they were evaluated after 30 weeks. Results: Axonal diameter was significantly larger in the supercharge group than in the nonsupercharge group for the buccal (3.78 ± 1.68 vs 3.16 ± 1.22; P < 0.0001) and marginal mandibular branches (3.97 ± 2.31 vs 3.46 ± 1.57; P < 0.0001), but the diameter was significantly larger in the intact group for all branches except the temporal branch. In the supercharge group, compound muscle action potential amplitude was significantly higher than in the nonsupercharge group (4.18 ± 1.49 mV vs 1.87 ± 0.37 mV; P < 0.0001) and similar to that in the intact group (4.11 ± 0.68 mV). Retrograde labeling showed that the mimetic muscles were double-innervated by facial and hypoglossal nerve nuclei in the supercharge group. Conclusions: Multiple facial nerve branch reconstruction with an end-to-side loop graft was able to achieve axonal distribution. Additionally, axonal supercharge from the hypoglossal nerve significantly improved outcomes. PMID:25426357
A New Method for Setting Calculation Sequence of Directional Relay Protection in Multi-Loop Networks
NASA Astrophysics Data System (ADS)
Haijun, Xiong; Qi, Zhang
2016-08-01
Workload of relay protection setting calculation in multi-loop networks may be reduced effectively by optimization setting calculation sequences. A new method of setting calculation sequences of directional distance relay protection in multi-loop networks based on minimum broken nodes cost vector (MBNCV) was proposed to solve the problem experienced in current methods. Existing methods based on minimum breakpoint set (MBPS) lead to more break edges when untying the loops in dependent relationships of relays leading to possibly more iterative calculation workloads in setting calculations. A model driven approach based on behavior trees (BT) was presented to improve adaptability of similar problems. After extending the BT model by adding real-time system characters, timed BT was derived and the dependency relationship in multi-loop networks was then modeled. The model was translated into communication sequence process (CSP) models and an optimization setting calculation sequence in multi-loop networks was finally calculated by tools. A 5-nodes multi-loop network was applied as an example to demonstrate effectiveness of the modeling and calculation method. Several examples were then calculated with results indicating the method effectively reduces the number of forced broken edges for protection setting calculation in multi-loop networks.
Automatic calculation of supersymmetric renormalization group equations and loop corrections
NASA Astrophysics Data System (ADS)
Staub, Florian
2011-03-01
SARAH is a Mathematica package for studying supersymmetric models. It calculates for a given model the masses, tadpole equations and all vertices at tree-level. This information can be used by SARAH to write model files for CalcHep/ CompHep or FeynArts/ FormCalc. In addition, the second version of SARAH can derive the renormalization group equations for the gauge couplings, parameters of the superpotential and soft-breaking parameters at one- and two-loop level. Furthermore, it calculates the one-loop self-energies and the one-loop corrections to the tadpoles. SARAH can handle all N=1 SUSY models whose gauge sector is a direct product of SU(N) and U(1) gauge groups. The particle content of the model can be an arbitrary number of chiral superfields transforming as any irreducible representation with respect to the gauge groups. To implement a new model, the user has just to define the gauge sector, the particle, the superpotential and the field rotations to mass eigenstates. Program summaryProgram title: SARAH Catalogue identifier: AEIB_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEIB_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 97 577 No. of bytes in distributed program, including test data, etc.: 2 009 769 Distribution format: tar.gz Programming language: Mathematica Computer: All systems that Mathematica is available for Operating system: All systems that Mathematica is available for Classification: 11.1, 11.6 Nature of problem: A supersymmetric model is usually characterized by the particle content, the gauge sector and the superpotential. It is a time consuming process to obtain all necessary information for phenomenological studies from these basic ingredients. Solution method: SARAH calculates the complete Lagrangian for a given model whose gauge sector can be any direct product of SU(N) gauge groups. The chiral superfields can transform as any, irreducible representation with respect to these gauge groups and it is possible to handle an arbitrary number of symmetry breakings or particle rotations. Also the gauge fixing terms can be specified. Using this information, SARAH derives the mass matrices and Feynman rules at tree-level and generates model files for CalcHep/CompHep and FeynArts/FormCalc. In addition, it can calculate the renormalization group equations at one- and two-loop level and the one-loop corrections to the one- and two-point functions. Unusual features: SARAH just needs the superpotential and gauge sector as input and not the complete Lagrangian. Therefore, the complete implementation of new models is done in some minutes. Running time: Measured CPU time for the evaluation of the MSSM on an Intel Q8200 with 2.33 GHz. Calculating the complete Lagrangian: 12 seconds. Calculating all vertices: 75 seconds. Calculating the one- and two-loop RGEs: 50 seconds. Calculating the one-loop corrections: 7 seconds. Writing a FeynArts file: 1 second. Writing a CalcHep/CompHep file: 6 seconds. Writing the LaTeX output: 1 second.
NASA Astrophysics Data System (ADS)
Volkov, Sergey
2017-11-01
This paper presents a new method of numerical computation of the mass-independent QED contributions to the electron anomalous magnetic moment which arise from Feynman graphs without closed electron loops. The method is based on a forestlike subtraction formula that removes all ultraviolet and infrared divergences in each Feynman graph before integration in Feynman-parametric space. The integration is performed by an importance sampling Monte-Carlo algorithm with the probability density function that is constructed for each Feynman graph individually. The method is fully automated at any order of the perturbation series. The results of applying the method to 2-loop, 3-loop, 4-loop Feynman graphs, and to some individual 5-loop graphs are presented, as well as the comparison of this method with other ones with respect to Monte Carlo convergence speed.
The Prevalence and Use of Walking Loops in Neighborhood Parks: A National Study
Cohen, Deborah A.; Han, Bing; Evenson, Kelly R.; Nagel, Catherine; McKenzie, Thomas L.; Marsh, Terry; Williamson, Stephanie; Harnik, Peter
2016-01-01
Background: Previous studies indicate that the design of streets and sidewalks can influence physical activity among residents. Park features also influence park use and park-based physical activity. Although individuals can walk on streets and sidewalks, walking loops in parks offer a setting to walk in nature and to avoid interruptions from traffic. Objectives: Here we describe the use of walking loops in parks and compare the number of park users and their physical activity in urban neighborhood parks with and without walking loops. Methods: We analyzed data from the National Study of Neighborhood Parks in which a representative sample of neighborhood parks (n = 174) from 25 U.S. cities with > 100,000 population were observed systematically to document facilities and park users by age group and sex. We compared the number of people and their physical activity in parks with and without walking loops, controlling for multiple factors, including park size, facilities, and population density. Results: Overall, compared with parks without walking loops, on average during an hourly observation, parks with walking loops had 80% more users (95% CI: 42, 139%), and levels of moderate-to-vigorous physical activity were 90% higher (95% CI: 49, 145%). The additional park use and park-based physical activity occurred not only on the walking loops but throughout the park. Conclusions: Walking loops may be a promising means of increasing population level physical activity. Further studies are needed to confirm a causal relationship. Citation: Cohen DA, Han B, Evenson KR, Nagel C, McKenzie TL, Marsh T, Williamson S, Harnik P. 2017. The prevalence and use of walking loops in neighborhood parks: a national study. Environ Health Perspect 125:170–174; http://dx.doi.org/10.1289/EHP293 PMID:27517530
A digital wireless system for closed-loop inhibition of nociceptive signals
NASA Astrophysics Data System (ADS)
Zuo, Chao; Yang, Xiaofei; Wang, Yang; Hagains, Christopher E.; Li, Ai-Ling; Peng, Yuan B.; Chiao, J.-C.
2012-10-01
Neurostimulation of the spinal cord or brain has been used to inhibit nociceptive signals in pain management applications. Nevertheless, most of the current neurostimulation models are based on open-loop system designs. There is a lack of closed-loop systems for neurostimulation in research with small freely-moving animals and in future clinical applications. Based on our previously developed analog wireless system for closed-loop neurostimulation, a digital wireless system with real-time feedback between recorder and stimulator modules has been developed to achieve multi-channel communication. The wireless system includes a wearable recording module, a wearable stimulation module and a transceiver connected to a computer for real-time and off-line data processing, display and storage. To validate our system, wide dynamic range neurons in the spinal cord dorsal horn have been recorded from anesthetized rats in response to graded mechanical stimuli (brush, pressure and pinch) applied in the hind paw. The identified nociceptive signals were used to automatically trigger electrical stimulation at the periaqueductal gray in real time to inhibit their own activities by the closed-loop design. Our digital wireless closed-loop system has provided a simplified and efficient method for further study of pain processing in freely-moving animals and potential clinical application in patients. Groups 1, 2 and 3 contributed equally to this project.
A Robust Inner and Outer Loop Control Method for Trajectory Tracking of a Quadrotor
Xia, Dunzhu; Cheng, Limei; Yao, Yanhong
2017-01-01
In order to achieve the complicated trajectory tracking of quadrotor, a geometric inner and outer loop control scheme is presented. The outer loop generates the desired rotation matrix for the inner loop. To improve the response speed and robustness, a geometric SMC controller is designed for the inner loop. The outer loop is also designed via sliding mode control (SMC). By Lyapunov theory and cascade theory, the closed-loop system stability is guaranteed. Next, the tracking performance is validated by tracking three representative trajectories. Then, the robustness of the proposed control method is illustrated by trajectory tracking in presence of model uncertainty and disturbances. Subsequently, experiments are carried out to verify the method. In the experiment, ultra wideband (UWB) is used for indoor positioning. Extended Kalman Filter (EKF) is used for fusing inertial measurement unit (IMU) and UWB measurements. The experimental results show the feasibility of the designed controller in practice. The comparative experiments with PD and PD loop demonstrate the robustness of the proposed control method. PMID:28925984
Hartmann's procedure vs loop colostomy in the treatment of obstructive rectosigmoid cancer.
Krstic, Slobodan; Resanovic, Vladimir; Alempijevic, Tamara; Resanovic, Aleksandar; Sijacki, Ana; Djukic, Vladimir; Loncar, Zlatibor; Karamarkovic, Aleksandar
2014-01-01
Colorectal carcinoma is the most common malignant gastrointestinal tumour. There is still a considerable controversy when it comes to urgent surgical treatment of obstructive carcinoma of the left colon and rectum. Seventy-five patients from the randomized trial were followed up. This study was designed as a stratified randomized trial with four stratums according to age and ASA score (older/younger than 60 years and ASA score <>3). Each of the four groups is then divided into two sub-groups according to the operating technique: loop colostomy or Hartmann's procedure. There were no difference found in hospitalization among the groups (loop colostomy vs. Hartmann's procedure) in the same stratus (P = 0.3192, P = 0.5760, P = 0.9023 respectively), except in the case of doing reconstructive procedure after loop colostomy (P = 0.0049) in the fourth stratum (patients younger than 60 years with ASA score lower than 3). Type of operation had no influence over the blood test values observed on admittance and during hospitalization (P = 0.319, P = 0.871, P = 0.7, P = 0.843, P = 0.52 respectively for the blood values). In terms of surgical and non-surgical complications it has been shown that there is no statistically significant difference between patients treated by two methods. Age, gender, ASA score, type of operation and surgical complications were not singled out as a risk factor for fatal outcome (P = 0.199, P = 0.155, P = 0.764, P = 0.452 and P = 0.724 respectively). The only factors that are singled out as a risk factor for death are the emergence of non-surgical complications and angina pectoris (P = 0.006, P = 0.001). There is no difference in surgical treatment of large bowel obstruction caused by rectosigmoid carcinoma. Neither of those two methods showed significant advantage in treatment of large bowel obstruction caused by rectosigmoid cancer.
47 CFR 51.232 - Binder group management.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 3 2012-10-01 2012-10-01 false Binder group management. 51.232 Section 51.232... Obligations of All Local Exchange Carriers § 51.232 Binder group management. (a) With the exception of loops..., segregating or reserving particular loops or binder groups for use solely by any particular advanced services...
47 CFR 51.232 - Binder group management.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 3 2013-10-01 2013-10-01 false Binder group management. 51.232 Section 51.232... Obligations of All Local Exchange Carriers § 51.232 Binder group management. (a) With the exception of loops..., segregating or reserving particular loops or binder groups for use solely by any particular advanced services...
47 CFR 51.232 - Binder group management.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 3 2011-10-01 2011-10-01 false Binder group management. 51.232 Section 51.232... Obligations of All Local Exchange Carriers § 51.232 Binder group management. (a) With the exception of loops..., segregating or reserving particular loops or binder groups for use solely by any particular advanced services...
A single-loop optimization method for reliability analysis with second order uncertainty
NASA Astrophysics Data System (ADS)
Xie, Shaojun; Pan, Baisong; Du, Xiaoping
2015-08-01
Reliability analysis may involve random variables and interval variables. In addition, some of the random variables may have interval distribution parameters owing to limited information. This kind of uncertainty is called second order uncertainty. This article develops an efficient reliability method for problems involving the three aforementioned types of uncertain input variables. The analysis produces the maximum and minimum reliability and is computationally demanding because two loops are needed: a reliability analysis loop with respect to random variables and an interval analysis loop for extreme responses with respect to interval variables. The first order reliability method and nonlinear optimization are used for the two loops, respectively. For computational efficiency, the two loops are combined into a single loop by treating the Karush-Kuhn-Tucker (KKT) optimal conditions of the interval analysis as constraints. Three examples are presented to demonstrate the proposed method.
Nakano, Yusuke; Mizuno, Tomofumi; Niwa, Toru; Mukai, Kentaro; Wakabayashi, Hirokazu; Watanabe, Atsushi; Ando, Hirohiko; Takashima, Hiroaki; Murotani, Kenta; Waseda, Katsuhisa; Amano, Tetsuya
2018-01-27
Tolvaptan (TLV) has an inhibiting effect for worsening renal function (WRF) in acute decompensated heart failure (HF) patients. However, there are limited data regarding the effect of continuous TLV administration on medium-term WRF.This was a retrospective observational study in hospitalized HF patients with chronic kidney disease (CKD). TLV was administered to those patients with fluid retention despite standard HF therapy. We compared 34 patients treated with TLV (TLV group) to 33 patients treated with conventional HF therapy with high-dose loop diuretics (furosemide ≥ 40 mg) (Loop group). Clinical outcomes, including the incidence of medium-term WRF, defined as increase of serum creatinine > 0.3 mg/dL, at 6 months after discharge and adverse events rate, were evaluated.Baseline patient characteristics were not different between the TLV and Loop group. The TLV group consisted of less frequent use of loop diuretics and carperitide compared with the Loop group. The incidence of medium-term WRF was significantly lower in the TLV group than in the Loop group (3.2% versus 31.0%, P = 0.002). Multivariate logistic analysis showed that the TLV non-user was an independent predictor of medium-term WRF. Kaplan-Meier analysis revealed that the long-term event-free survival was significantly higher in the TLV group (log-rank P = 0.01).Continuous administration of TLV may reduce the risk of medium-term WRF, resulting possibility in improvement of long-term adverse outcomes in HF patients with CKD.
An optimal open/closed-loop control method with application to a pre-stressed thin duralumin plate
NASA Astrophysics Data System (ADS)
Nadimpalli, Sruthi Raju
The excessive vibrations of a pre-stressed duralumin plate, suppressed by a combination of open-loop and closed-loop controls, also known as open/closed-loop control, is studied in this thesis. The two primary steps involved in this process are: Step (I) with an assumption that the closed-loop control law is proportional, obtain the optimal open-loop control by direct minimization of the performance measure consisting of energy at terminal time and a penalty on open-loop control force via calculus of variations. If the performance measure also involves a penalty on closed-loop control effort then a Fourier based method is utilized. Step (II) the energy at terminal time is minimized numerically to obtain optimal values of feedback gains. The optimal closed-loop control gains obtained are used to describe the displacement and the velocity of open-loop, closed-loop and open/closed-loop controlled duralumin plate.
ERIC Educational Resources Information Center
Jones, Eric E.; Kelly, Janice R.
2013-01-01
Knowledge specialization, such as that present in cross-functional teams, produces both positive and negative outcomes. Our research investigated how unique expertise can lead to feelings of ostracism in the form of being out of the loop. Compared to group members with shared expertise, members with unique expertise felt out of the loop and…
Rinehart, Joseph; Chung, Elena; Canales, Cecilia; Cannesson, Maxime
2012-10-01
The authors compared the performance of a group of anesthesia providers to closed-loop (Learning Intravenous Resuscitator [LIR]) management in a simulated hemorrhage scenario using cardiac output monitoring. A prospective cohort study. In silico simulation. University hospital anesthesiologists and the LIR closed-loop fluid administration system. Using a patient simulator, a 90-minute simulated hemorrhage protocol was run, which included a 1,200-mL blood loss over 30 minutes. Twenty practicing anesthesiology providers were asked to manage this scenario by providing fluids and vasopressor medication at their discretion. The simulation program was also run 20 times with the LIR closed-loop algorithm managing fluids and an additional 20 times with no intervention. Simulated patient weight, height, heart rate, mean arterial pressure, and cardiac output (CO) were similar at baseline. The mean stroke volume, the mean arterial pressure, CO, and the final CO were higher in the closed-loop group than in the practitioners group, and the coefficient of variance was lower. The closed-loop group received slightly more fluid (2.1 v 1.9 L, p < 0.05) than the anesthesiologist group. Despite the roughly similar volumes of fluid given, the closed-loop maintained more stable hemodynamics than the practitioners primarily because the fluid was given earlier in the protocol and CO optimized before the hemorrhage began, whereas practitioners tended to resuscitate well but only after significant hemodynamic change indicated the need. Overall, these data support the potential usefulness of this closed-loop algorithm in clinical settings in which dynamic predictors are not available or applicable. Published by Elsevier Inc.
Reduced Perfusion in Broca’s Area in Developmental Stuttering
Desai, Jay; Huo, Yuankai; Wang, Zhishun; Bansal, Ravi; Williams, Steven C. R.; Lythgoe, David; Zelaya, Fernando O.; Peterson, Bradley S.
2016-01-01
Objective To study resting cerebral blood flow in children and adults with developmental stuttering. Methods We acquired pulsed arterial spin labeling magnetic resonance imaging data in 26 participants with stuttering and 36 healthy, fluent controls. While covarying for age, sex, and IQ, we compared perfusion values voxel-wise across diagnostic groups and assessed correlations of perfusion with stuttering severity within the stuttering group and with measures of motor speed in both groups. Results We detected lower regional Cerebral Blood Flow (rCBF) at rest in the stuttering group compared to healthy controls in Broca’s area bilaterally and the superior frontal gyrus. rCBF values in Broca’s area bilaterally correlated inversely with the severity of stuttering and extended posteriorly into other portions of the language loop. We also found increased rCBF in cerebellar nuclei and parietal cortex in the stuttering group compared to healthy controls. Findings were unchanged in child-only analyses and when excluding participants with comorbid illnesses or those taking medication. Conclusions rCBF is reduced in Broca’s region in persons who stutter. More severe stuttering is associated with even greater reductions in rCBF to Broca’s region, additive to the underlying putative trait reduction in rCBF relative to control values. Moreover, a greater abnormality in rCBF in the posterior language loop is associated with more severe symptoms, suggesting that a common pathophysiology throughout the language loop likely contributes to stuttering severity. PMID:28035724
Comparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy
Faramarzi, Mohammad; Gilanifar, Nafiseh; Roosta, Sareh
2017-01-01
Introduction: Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis. Materials and Methods: A total of 57 ears were included in the soft-clip group and 63 ears were included in the Teflon-piston group. Pre-operative and post-operative air conduction, bone conduction, air-bone gaps, speech discrimination score, and speech reception thresholds were analyzed. Results: Post-operative speech reception threshold gains did not differ significantly between the two groups (P=0.919). However, better post-operative air-bone gap improvement at low frequencies was observed in the Teflon-piston group over the short-term follow-up (at frequencies of 0.25 and 0.50 kHz; P=0.007 and P=0.001, respectively). Conclusion: Similar post-operative hearing results were observed in the two groups in the short-term. PMID:28229059
A Method to Predict the Structure and Stability of RNA/RNA Complexes.
Xu, Xiaojun; Chen, Shi-Jie
2016-01-01
RNA/RNA interactions are essential for genomic RNA dimerization and regulation of gene expression. Intermolecular loop-loop base pairing is a widespread and functionally important tertiary structure motif in RNA machinery. However, computational prediction of intermolecular loop-loop base pairing is challenged by the entropy and free energy calculation due to the conformational constraint and the intermolecular interactions. In this chapter, we describe a recently developed statistical mechanics-based method for the prediction of RNA/RNA complex structures and stabilities. The method is based on the virtual bond RNA folding model (Vfold). The main emphasis in the method is placed on the evaluation of the entropy and free energy for the loops, especially tertiary kissing loops. The method also uses recursive partition function calculations and two-step screening algorithm for large, complicated structures of RNA/RNA complexes. As case studies, we use the HIV-1 Mal dimer and the siRNA/HIV-1 mutant (T4) to illustrate the method.
F4 symmetric ϕ3 theory at four loops
NASA Astrophysics Data System (ADS)
Gracey, J. A.
2017-03-01
The renormalization group functions for six dimensional scalar ϕ3 theory with an F4 symmetry are provided at four loops in the modified minimal subtraction (MS ¯ ) scheme. Aside from the anomalous dimension of ϕ and the β -function this includes the mass operator and a ϕ2-type operator. The anomalous dimension of the latter is computed explicitly at four loops for the 26 and 324 representations of F4. The ɛ expansion of all the related critical exponents are determined to O (ɛ4). For instance the value for Δϕ agrees with recent conformal bootstrap estimates in 5 and 5.95 dimensions. The renormalization group functions are also provided at four loops for the group E6.
Method of implementing digital phase-locked loops
NASA Technical Reports Server (NTRS)
Stephens, Scott A. (Inventor); Thomas, Jess Brooks, Jr. (Inventor)
1993-01-01
In a new formulation for digital phase-locked loops, loop-filter constants are determined from loop roots that can each be selectively placed in the s-plane on the basis of a new set of parameters, each with simple and direct physical meaning in terms of loop noise bandwidth, root-specific decay rate, or root-specific damping. Loops of first to fourth order are treated in the continuous-update approximation (BLT yields 0) and in a discrete-update formulation with arbitrary BLT. Deficiencies of the continuous-update approximation in large-BLT applications are avoided in the new discrete-update formulation. A new method for direct, transient-free acquisition with third- and fourth-order loops can improve the versatility and reliability of acquisition with such loops.
Won, Jonghun; Lee, Gyu Rie; Park, Hahnbeom; Seok, Chaok
2018-06-07
The second extracellular loops (ECL2s) of G-protein-coupled receptors (GPCRs) are often involved in GPCR functions, and their structures have important implications in drug discovery. However, structure prediction of ECL2 is difficult because of its long length and the structural diversity among different GPCRs. In this study, a new ECL2 conformational sampling method involving both template-based and ab initio sampling was developed. Inspired by the observation of similar ECL2 structures of closely related GPCRs, a template-based sampling method employing loop structure templates selected from the structure database was developed. A new metric for evaluating similarity of the target loop to templates was introduced for template selection. An ab initio loop sampling method was also developed to treat cases without highly similar templates. The ab initio method is based on the previously developed fragment assembly and loop closure method. A new sampling component that takes advantage of secondary structure prediction was added. In addition, a conserved disulfide bridge restraining ECL2 conformation was predicted and analytically incorporated into sampling, reducing the effective dimension of the conformational search space. The sampling method was combined with an existing energy function for comparison with previously reported loop structure prediction methods, and the benchmark test demonstrated outstanding performance.
Unbiased, scalable sampling of protein loop conformations from probabilistic priors.
Zhang, Yajia; Hauser, Kris
2013-01-01
Protein loops are flexible structures that are intimately tied to function, but understanding loop motion and generating loop conformation ensembles remain significant computational challenges. Discrete search techniques scale poorly to large loops, optimization and molecular dynamics techniques are prone to local minima, and inverse kinematics techniques can only incorporate structural preferences in adhoc fashion. This paper presents Sub-Loop Inverse Kinematics Monte Carlo (SLIKMC), a new Markov chain Monte Carlo algorithm for generating conformations of closed loops according to experimentally available, heterogeneous structural preferences. Our simulation experiments demonstrate that the method computes high-scoring conformations of large loops (>10 residues) orders of magnitude faster than standard Monte Carlo and discrete search techniques. Two new developments contribute to the scalability of the new method. First, structural preferences are specified via a probabilistic graphical model (PGM) that links conformation variables, spatial variables (e.g., atom positions), constraints and prior information in a unified framework. The method uses a sparse PGM that exploits locality of interactions between atoms and residues. Second, a novel method for sampling sub-loops is developed to generate statistically unbiased samples of probability densities restricted by loop-closure constraints. Numerical experiments confirm that SLIKMC generates conformation ensembles that are statistically consistent with specified structural preferences. Protein conformations with 100+ residues are sampled on standard PC hardware in seconds. Application to proteins involved in ion-binding demonstrate its potential as a tool for loop ensemble generation and missing structure completion.
Unbiased, scalable sampling of protein loop conformations from probabilistic priors
2013-01-01
Background Protein loops are flexible structures that are intimately tied to function, but understanding loop motion and generating loop conformation ensembles remain significant computational challenges. Discrete search techniques scale poorly to large loops, optimization and molecular dynamics techniques are prone to local minima, and inverse kinematics techniques can only incorporate structural preferences in adhoc fashion. This paper presents Sub-Loop Inverse Kinematics Monte Carlo (SLIKMC), a new Markov chain Monte Carlo algorithm for generating conformations of closed loops according to experimentally available, heterogeneous structural preferences. Results Our simulation experiments demonstrate that the method computes high-scoring conformations of large loops (>10 residues) orders of magnitude faster than standard Monte Carlo and discrete search techniques. Two new developments contribute to the scalability of the new method. First, structural preferences are specified via a probabilistic graphical model (PGM) that links conformation variables, spatial variables (e.g., atom positions), constraints and prior information in a unified framework. The method uses a sparse PGM that exploits locality of interactions between atoms and residues. Second, a novel method for sampling sub-loops is developed to generate statistically unbiased samples of probability densities restricted by loop-closure constraints. Conclusion Numerical experiments confirm that SLIKMC generates conformation ensembles that are statistically consistent with specified structural preferences. Protein conformations with 100+ residues are sampled on standard PC hardware in seconds. Application to proteins involved in ion-binding demonstrate its potential as a tool for loop ensemble generation and missing structure completion. PMID:24565175
Conformational Sampling in Template-Free Protein Loop Structure Modeling: An Overview
Li, Yaohang
2013-01-01
Accurately modeling protein loops is an important step to predict three-dimensional structures as well as to understand functions of many proteins. Because of their high flexibility, modeling the three-dimensional structures of loops is difficult and is usually treated as a “mini protein folding problem” under geometric constraints. In the past decade, there has been remarkable progress in template-free loop structure modeling due to advances of computational methods as well as stably increasing number of known structures available in PDB. This mini review provides an overview on the recent computational approaches for loop structure modeling. In particular, we focus on the approaches of sampling loop conformation space, which is a critical step to obtain high resolution models in template-free methods. We review the potential energy functions for loop modeling, loop buildup mechanisms to satisfy geometric constraints, and loop conformation sampling algorithms. The recent loop modeling results are also summarized. PMID:24688696
Conformational sampling in template-free protein loop structure modeling: an overview.
Li, Yaohang
2013-01-01
Accurately modeling protein loops is an important step to predict three-dimensional structures as well as to understand functions of many proteins. Because of their high flexibility, modeling the three-dimensional structures of loops is difficult and is usually treated as a "mini protein folding problem" under geometric constraints. In the past decade, there has been remarkable progress in template-free loop structure modeling due to advances of computational methods as well as stably increasing number of known structures available in PDB. This mini review provides an overview on the recent computational approaches for loop structure modeling. In particular, we focus on the approaches of sampling loop conformation space, which is a critical step to obtain high resolution models in template-free methods. We review the potential energy functions for loop modeling, loop buildup mechanisms to satisfy geometric constraints, and loop conformation sampling algorithms. The recent loop modeling results are also summarized.
Near-Native Protein Loop Sampling Using Nonparametric Density Estimation Accommodating Sparcity
Day, Ryan; Lennox, Kristin P.; Sukhanov, Paul; Dahl, David B.; Vannucci, Marina; Tsai, Jerry
2011-01-01
Unlike the core structural elements of a protein like regular secondary structure, template based modeling (TBM) has difficulty with loop regions due to their variability in sequence and structure as well as the sparse sampling from a limited number of homologous templates. We present a novel, knowledge-based method for loop sampling that leverages homologous torsion angle information to estimate a continuous joint backbone dihedral angle density at each loop position. The φ,ψ distributions are estimated via a Dirichlet process mixture of hidden Markov models (DPM-HMM). Models are quickly generated based on samples from these distributions and were enriched using an end-to-end distance filter. The performance of the DPM-HMM method was evaluated against a diverse test set in a leave-one-out approach. Candidates as low as 0.45 Å RMSD and with a worst case of 3.66 Å were produced. For the canonical loops like the immunoglobulin complementarity-determining regions (mean RMSD <2.0 Å), the DPM-HMM method performs as well or better than the best templates, demonstrating that our automated method recaptures these canonical loops without inclusion of any IgG specific terms or manual intervention. In cases with poor or few good templates (mean RMSD >7.0 Å), this sampling method produces a population of loop structures to around 3.66 Å for loops up to 17 residues. In a direct test of sampling to the Loopy algorithm, our method demonstrates the ability to sample nearer native structures for both the canonical CDRH1 and non-canonical CDRH3 loops. Lastly, in the realistic test conditions of the CASP9 experiment, successful application of DPM-HMM for 90 loops from 45 TBM targets shows the general applicability of our sampling method in loop modeling problem. These results demonstrate that our DPM-HMM produces an advantage by consistently sampling near native loop structure. The software used in this analysis is available for download at http://www.stat.tamu.edu/~dahl/software/cortorgles/. PMID:22028638
Fast de novo discovery of low-energy protein loop conformations.
Wong, Samuel W K; Liu, Jun S; Kou, S C
2017-08-01
In the prediction of protein structure from amino acid sequence, loops are challenging regions for computational methods. Since loops are often located on the protein surface, they can have significant roles in determining protein functions and binding properties. Loop prediction without the aid of a structural template requires extensive conformational sampling and energy minimization, which are computationally difficult. In this article we present a new de novo loop sampling method, the Parallely filtered Energy Targeted All-atom Loop Sampler (PETALS) to rapidly locate low energy conformations. PETALS explores both backbone and side-chain positions of the loop region simultaneously according to the energy function selected by the user, and constructs a nonredundant ensemble of low energy loop conformations using filtering criteria. The method is illustrated with the DFIRE potential and DiSGro energy function for loops, and shown to be highly effective at discovering conformations with near-native (or better) energy. Using the same energy function as the DiSGro algorithm, PETALS samples conformations with both lower RMSDs and lower energies. PETALS is also useful for assessing the accuracy of different energy functions. PETALS runs rapidly, requiring an average time cost of 10 minutes for a length 12 loop on a single 3.2 GHz processor core, comparable to the fastest existing de novo methods for generating an ensemble of conformations. Proteins 2017; 85:1402-1412. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Validation of Digital Systems in Avionics and Flight Control Applications Handbook. Volume 1.
1983-07-01
will also be available to Airways Facilities, Systems Research and Development Service, Air Traffic Control Service, and Flight Standards elements...2114, March 12-14, 1979. 3. Validation Methods Research for Fault-Tolerant Avionics and Control Systems-- *r Working Group Meeting II, NASA...command generation with the multiple methods becoming avail- able for closure of the outer control loop necessitates research on alternative integration
Zheng, Yue; Zhang, Chunxi; Li, Lijing; Song, Lailiang; Chen, Wen
2016-06-10
For a fiber-optic gyroscope (FOG) using electronic dithers to suppress the dead zone, without a fixed loop gain, the deterministic compensation for the dither signals in the control loop of the FOG cannot remain accurate, resulting in the dither residuals in the FOG rotation rate output and the navigation errors in the inertial navigation system. An all-digital automatic-gain-control method for stabilizing the loop gain of the FOG is proposed. By using a perturbation square wave to measure the loop gain of the FOG and adding an automatic gain control loop in the conventional control loop of the FOG, we successfully obtain the actual loop gain and make the loop gain converge to the reference value. The experimental results show that in the case of 20% variation in the loop gain, the dither residuals are successfully eliminated and the standard deviation of the FOG sampling outputs is decreased from 2.00 deg/h to 0.62 deg/h (sampling period 2.5 ms, 10 points smoothing). With this method, the loop gain of the FOG can be stabilized over the operation temperature range and in the long-time application, which provides a solid foundation for the engineering applications of the high-precision FOG.
Wilson loops on Riemann surfaces, Liouville theory and covariantization of the conformal group
NASA Astrophysics Data System (ADS)
Matone, Marco; Pasti, Paolo
2015-06-01
The covariantization procedure is usually referred to the translation operator, that is the derivative. Here we introduce a general method to covariantize arbitrary differential operators, such as the ones defining the fundamental group of a given manifold. We focus on the differential operators representing the sl2(ℝ) generators, which in turn, generate, by exponentiation, the two-dimensional conformal transformations. A key point of our construction is the recent result on the closed forms of the Baker-Campbell-Hausdorff formula. In particular, our covariantization receipt is quite general. This has a deep consequence since it means that the covariantization of the conformal group is always definite. Our covariantization receipt is quite general and apply in general situations, including AdS/CFT. Here we focus on the projective unitary representations of the fundamental group of a Riemann surface, which may include elliptic points and punctures, introduced in the framework of noncommutative Riemann surfaces. It turns out that the covariantized conformal operators are built in terms of Wilson loops around Poincaré geodesics, implying a deep relationship between gauge theories on Riemann surfaces and Liouville theory.
A method for reducing sampling jitter in digital control systems
NASA Technical Reports Server (NTRS)
Anderson, T. O.; HURBD W. J.; Hurd, W. J.
1969-01-01
Digital phase lock loop system is designed by smoothing the proportional control with a low pass filter. This method does not significantly affect the loop dynamics when the smoothing filter bandwidth is wide compared to loop bandwidth.
Zhang, Lei; Zhou, Xin; Qi, Ji; Zeng, Yan; Zhang, Shaoqun; Liu, Gang; Ping, Ruiyue; Li, Yikai; Fu, Shijie
2018-01-01
Acromioclavicular dislocation (ACD) is a common injury. According to the Rockwood classification, ACD is classified into six types (type I–VI); however, for type III injuries, it remains controversial whether or not operative treatment should be applied. Numerous studies have advocated early surgical treatment to ensure early rehabilitation activities. Thus, the present study aimed to investigate a modified closed-loop double-endobutton technique (MCDT), that may be used to repair Rockwood type III ACD. In the current study, 61 patients with Rockwood type III ACD were enrolled during a period of 5 years at the Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University. Patients were divided into three groups according to the surgical method used, the MCDT group (n=20), the common closed-loop double-endobutton technique (CCDT) group (n=21), and the clavicular hook plate fixation (CHPF) group (n=20). Preoperative and intraoperative information were recorded. Furthermore, the functional scores of injured shoulder were evaluated prior to surgery and following surgery with a 1-year follow-up. Among the three groups, postoperative functional scores were significantly more improved compared with those prior to surgery (P<0.05), and no significant difference was observed regarding the coracoclavicular interval with the 1-year follow-up (P>0.05). Postoperative functional scores in the MCDT and CCDT groups were significantly more improved compared those in the CHPF group (P<0.05). In addition, the duration of surgery in the MCDT group was significantly shorter compared with that in the CCDT group (P<0.05). Furthermore, compared with the CHPF group, the incision length was significantly shorter with reduced hemorrhage in the MCDT group (P<0.05). In conclusion, the results of the current study suggest that MCDT is more simple, convenient and efficient compared with CCDT, and is worth popularizing. PMID:29399102
Two-loop renormalization of gaugino masses in general supersymmetric gauge models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamada, Y.
1994-01-03
We calculate the two-loop renormalization group equations for the running gaugino masses in general supersymmetry (SUSY) gauge models, improving our previous result. We also study its consequences on the unification of the gaugino masses in the SUSY SU(5) model. The two-loop correction to the one-loop relation [ital m][sub [ital i
Evaluating Mathematics Achievement of Middle School Students in a Looping Environment
ERIC Educational Resources Information Center
Franz, Dana Pomykal; Thompson, Nicole L.; Fuller, Bob; Hare, R. Dwight; Miller, Nicole C.; Walker, Jacob
2010-01-01
Looping, a school structure where students remain with one group of teachers for two or more school years, is used by middle schools to meet the diverse needs of young adolescents. However, little research exists on how looping effects the academic performance of students. This study was designed to determine if looping influenced middle school…
NASA Astrophysics Data System (ADS)
Ishii, Masanori; Kim, Jeong Hwan; Ji, Yu; Cho, Chi Hyun; Zhang, Tim
2018-01-01
The supplementary comparison report APMP.RF-S21.F describes the comparison of loop antennas, which was conducted between April 2013 and January 2014. The two comparison artefacts were well-characterised active loop antennas of diameter 30 cm and 60 cm respectively, which typically operate in a frequency range from 9 kHz to 30 MHz. These antennas represent the main groups of antennas which are used around the world for EMC measurements in the frequency range below 30 MHz. There are several well-known methods for calibrating the antenna factor of these devices. The calibration systems used in this comparison for the loop antennas employed the standard magnetic field method or the three-antenna method. Despite the limitations of the algorithm, which we used to derive the reference value for each case (particularly for small samples), the actual calculated reference values seem to be reasonable. As a result, the agreement between each participant was very good in all cases. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Comparison of cervical dysplasia treatment with leep-loop method and CO2 laser vaporization
NASA Astrophysics Data System (ADS)
Wozniak, Jakub; Rzymski, Pawel; Opala, Tomasz; Wilczak, Maciej; Sajdak, Stefan
2003-10-01
There are several methods of treating cervical dysplasia, including surgical and electric conisation, laservaporisation. The aim of our study was to evaluate leep-loop method and laservaporisation wtih CO2 laser. Material consisted of 49 women, 28 underwent leep-loop conisation and 21 lavervaporisation. The effectiveness of laser treatment was 90,4% and with leep-loop 96,4%, but the difference was not statistically significant. Mean time of wound healing and frequency of pain was shorter after laser treatment, but the differences were not statistically significant. Conclusions: Effect treatment with both methods is comparable.
Effect of Loop Geometry on TEM Response Over Layered Earth
NASA Astrophysics Data System (ADS)
Qi, Youzheng; Huang, Ling; Wu, Xin; Fang, Guangyou; Yu, Gang
2014-09-01
A large horizontal loop located on the ground or carried by an aircraft are the most common sources of the transient electromagnetic method. Although topographical factors or airplane outlines make the loop of arbitrary shape, magnetic sources are generally represented as a magnetic dipole or a circular loop, which may bring about significant errors in the calculated response. In this paper, we present a method for calculating the response of a loop of arbitrary shape (for which the description can be obtained by different methods, including GPS localization) in air or on the surface of a stratified earth. The principle of reciprocity is firstly used to exchange the functions of the transmitting loop and the dipole receiver, then the response of a vertical or a horizontal magnetic dipole is calculated beforehand, and finally the line integral of the second kind is employed to get the transient response. Analytical analysis and comparisons depict that our work got very good results in many situations. Synthetic and field examples are given in the end to show the effect of loop geometry and how our method improves the precision of the EM response.
Quantifying the ventilatory control contribution to sleep apnoea using polysomnography.
Terrill, Philip I; Edwards, Bradley A; Nemati, Shamim; Butler, James P; Owens, Robert L; Eckert, Danny J; White, David P; Malhotra, Atul; Wellman, Andrew; Sands, Scott A
2015-02-01
Elevated loop gain, consequent to hypersensitive ventilatory control, is a primary nonanatomical cause of obstructive sleep apnoea (OSA) but it is not possible to quantify this in the clinic. Here we provide a novel method to estimate loop gain in OSA patients using routine clinical polysomnography alone. We use the concept that spontaneous ventilatory fluctuations due to apnoeas/hypopnoeas (disturbance) result in opposing changes in ventilatory drive (response) as determined by loop gain (response/disturbance). Fitting a simple ventilatory control model (including chemical and arousal contributions to ventilatory drive) to the ventilatory pattern of OSA reveals the underlying loop gain. Following mathematical-model validation, we critically tested our method in patients with OSA by comparison with a standard (continuous positive airway pressure (CPAP) drop method), and by assessing its ability to detect the known reduction in loop gain with oxygen and acetazolamide. Our method quantified loop gain from baseline polysomnography (correlation versus CPAP-estimated loop gain: n=28; r=0.63, p<0.001), detected the known reduction in loop gain with oxygen (n=11; mean±sem change in loop gain (ΔLG) -0.23±0.08, p=0.02) and acetazolamide (n=11; ΔLG -0.20±0.06, p=0.005), and predicted the OSA response to loop gain-lowering therapy. We validated a means to quantify the ventilatory control contribution to OSA pathogenesis using clinical polysomnography, enabling identification of likely responders to therapies targeting ventilatory control. Copyright ©ERS 2015.
Quantifying the ventilatory control contribution to sleep apnoea using polysomnography
Terrill, Philip I.; Edwards, Bradley A.; Nemati, Shamim; Butler, James P.; Owens, Robert L.; Eckert, Danny J.; White, David P.; Malhotra, Atul; Wellman, Andrew; Sands, Scott A.
2015-01-01
Elevated loop gain, consequent to hypersensitive ventilatory control, is a primary nonanatomical cause of obstructive sleep apnoea (OSA) but it is not possible to quantify this in the clinic. Here we provide a novel method to estimate loop gain in OSA patients using routine clinical polysomnography alone. We use the concept that spontaneous ventilatory fluctuations due to apnoeas/hypopnoeas (disturbance) result in opposing changes in ventilatory drive (response) as determined by loop gain (response/disturbance). Fitting a simple ventilatory control model (including chemical and arousal contributions to ventilatory drive) to the ventilatory pattern of OSA reveals the underlying loop gain. Following mathematical-model validation, we critically tested our method in patients with OSA by comparison with a standard (continuous positive airway pressure (CPAP) drop method), and by assessing its ability to detect the known reduction in loop gain with oxygen and acetazolamide. Our method quantified loop gain from baseline polysomnography (correlation versus CPAP-estimated loop gain: n=28; r=0.63, p<0.001), detected the known reduction in loop gain with oxygen (n=11; mean±SEM change in loop gain (ΔLG) −0.23±0.08, p=0.02) and acetazolamide (n=11; ΔLG −0.20±0.06, p=0.005), and predicted the OSA response to loop gain-lowering therapy. We validated a means to quantify the ventilatory control contribution to OSA pathogenesis using clinical polysomnography, enabling identification of likely responders to therapies targeting ventilatory control. PMID:25323235
Working memory subsystems and task complexity in young boys with Fragile X syndrome
Baker, S.; Hooper, S.; Skinner, M.; Hatton, D.; Schaaf, J.; Ornstein, P.; Bailey, D.
2011-01-01
Background Working memory problems have been targeted as core deficits in individuals with Fragile X syndrome (FXS); however, there have been few studies that have examined working memory in young boys with FXS, and even fewer studies that have studied the working memory performance of young boys with FXS across different degrees of complexity. The purpose of this study was to investigate the phonological loop and visual–spatial working memory in young boys with FXS, in comparison to mental age-matched typical boys, and to examine the impact of complexity of the working memory tasks on performance. Methods The performance of young boys (7 to 13-years-old) with FXS (n = 40) was compared with that of mental age and race matched typically developing boys (n = 40) on measures designed to test the phonological loop and the visuospatial sketchpad across low, moderate and high degrees of complexity. Multivariate analyses were used to examine group differences across the specific working memory systems and degrees of complexity. Results Results suggested that boys with FXS showed deficits in phonological loop and visual–spatial working memory tasks when compared with typically developing mental age-matched boys. For the boys with FXS, the phonological loop was significantly lower than the visual–spatial sketchpad; however, there was no significant difference in performance across the low, moderate and high degrees of complexity in the working memory tasks. Reverse tasks from both the phonological loop and visual–spatial sketchpad appeared to be the most challenging for both groups, but particularly for the boys with FXS. Conclusions These findings implicate a generalised deficit in working memory in young boys with FXS, with a specific disproportionate impairment in the phonological loop. Given the lack of differentiation on the low versus high complexity tasks, simple span tasks may provide an adequate estimate of working memory until greater involvement of the central executive is achieved. PMID:21121991
Prism adaptation and neck muscle vibration in healthy individuals: are two methods better than one?
Guinet, M; Michel, C
2013-12-19
Studies involving therapeutic combinations reveal an important benefit in the rehabilitation of neglect patients when compared to single therapies. In light of these observations our present work examines, in healthy individuals, sensorimotor and cognitive after-effects of prism adaptation and neck muscle vibration applied individually or simultaneously. We explored sensorimotor after-effects on visuo-manual open-loop pointing, visual and proprioceptive straight-ahead estimations. We assessed cognitive after-effects on the line bisection task. Fifty-four healthy participants were divided into six groups designated according to the exposure procedure used with each: 'Prism' (P) group; 'Vibration with a sensation of body rotation' (Vb) group; 'Vibration with a move illusion of the LED' (Vl) group; 'Association with a sensation of body rotation' (Ab) group; 'Association with a move illusion of the LED' (Al) group; and 'Control' (C) group. The main findings showed that prism adaptation applied alone or combined with vibration showed significant adaptation in visuo-manual open-loop pointing, visual straight-ahead and proprioceptive straight-ahead. Vibration alone produced significant after-effects on proprioceptive straight-ahead estimation in the Vl group. Furthermore all groups (except C group) showed a rightward neglect-like bias in line bisection following the training procedure. This is the first demonstration of cognitive after-effects following neck muscle vibration in healthy individuals. The simultaneous application of both methods did not produce significant greater after-effects than prism adaptation alone in both sensorimotor and cognitive tasks. These results are discussed in terms of transfer of sensorimotor plasticity to spatial cognition in healthy individuals. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.
Methods of forming thermal management systems and thermal management methods
Gering, Kevin L.; Haefner, Daryl R.
2012-06-05
A thermal management system for a vehicle includes a heat exchanger having a thermal energy storage material provided therein, a first coolant loop thermally coupled to an electrochemical storage device located within the first coolant loop and to the heat exchanger, and a second coolant loop thermally coupled to the heat exchanger. The first and second coolant loops are configured to carry distinct thermal energy transfer media. The thermal management system also includes an interface configured to facilitate transfer of heat generated by an internal combustion engine to the heat exchanger via the second coolant loop in order to selectively deliver the heat to the electrochemical storage device. Thermal management methods are also provided.
Multi-loop Integrand Reduction with Computational Algebraic Geometry
NASA Astrophysics Data System (ADS)
Badger, Simon; Frellesvig, Hjalte; Zhang, Yang
2014-06-01
We discuss recent progress in multi-loop integrand reduction methods. Motivated by the possibility of an automated construction of multi-loop amplitudes via generalized unitarity cuts we describe a procedure to obtain a general parameterisation of any multi-loop integrand in a renormalizable gauge theory. The method relies on computational algebraic geometry techniques such as Gröbner bases and primary decomposition of ideals. We present some results for two and three loop amplitudes obtained with the help of the MACAULAY2 computer algebra system and the Mathematica package BASISDET.
Stability of disclination loop in pure twist nematic liquid crystals
NASA Astrophysics Data System (ADS)
Kadivar, Erfan
2018-04-01
In this work, the annihilations dynamics and stability of disclination loop in a bulk pure twist nematic liquid crystal are investigated. This work is based on the Frank free energy and the nematodynamics equations. The energy dissipation is calculated by using two methods. In the first method, the energy dissipation is obtained from the Frank free energy. In the second method, it is calculated by using the nematodynamics equations. Finally, we derive a critical radius of disclination loop that above this radius, loop creation is energetically forbidden.
A comparison of methods for DPLL loop filter design
NASA Technical Reports Server (NTRS)
Aguirre, S.; Hurd, W. J.; Kumar, R.; Statman, J.
1986-01-01
Four design methodologies for loop filters for a class of digital phase-locked loops (DPLLs) are presented. The first design maps an optimum analog filter into the digital domain; the second approach designs a filter that minimizes in discrete time weighted combination of the variance of the phase error due to noise and the sum square of the deterministic phase error component; the third method uses Kalman filter estimation theory to design a filter composed of a least squares fading memory estimator and a predictor. The last design relies on classical theory, including rules for the design of compensators. Linear analysis is used throughout the article to compare different designs, and includes stability, steady state performance and transient behavior of the loops. Design methodology is not critical when the loop update rate can be made high relative to loop bandwidth, as the performance approaches that of continuous time. For low update rates, however, the miminization method is significantly superior to the other methods.
Navigating around the algebraic jungle of QCD: efficient evaluation of loop helicity amplitudes
NASA Astrophysics Data System (ADS)
Lam, C. S.
1993-05-01
A method is developed whereby spinor helicity techniques can be used to simlify the calculation of loop amplitudes. This is achieved by using the Feynman-parameter representation where the offending off-shell loop momenta do not appear. Other shortcuts motivated by the Bern-Kosower one-loop string calculations can be incorporated into the formalism. This includes color reorganization into Chan-Paton factors and the use of background Feynman gauge. This method is applicable to any Feynman diagram with any number of loops as long as the external masses can be ignored. In order to minimize the very considerable algebra encountered in non-abelian gauge theories, graphical methods are developed for most of the calculations. This enables the large number of terms encountered to be organized implicitly in the Feynman diagram without the necessity of writing down any of them algebraically. A one-loop four-gluon amplitude in a particular helicity configuration is computed explicitly to illustrate the method.
NASA Astrophysics Data System (ADS)
Beck, Joakim; Dia, Ben Mansour; Espath, Luis F. R.; Long, Quan; Tempone, Raúl
2018-06-01
In calculating expected information gain in optimal Bayesian experimental design, the computation of the inner loop in the classical double-loop Monte Carlo requires a large number of samples and suffers from underflow if the number of samples is small. These drawbacks can be avoided by using an importance sampling approach. We present a computationally efficient method for optimal Bayesian experimental design that introduces importance sampling based on the Laplace method to the inner loop. We derive the optimal values for the method parameters in which the average computational cost is minimized according to the desired error tolerance. We use three numerical examples to demonstrate the computational efficiency of our method compared with the classical double-loop Monte Carlo, and a more recent single-loop Monte Carlo method that uses the Laplace method as an approximation of the return value of the inner loop. The first example is a scalar problem that is linear in the uncertain parameter. The second example is a nonlinear scalar problem. The third example deals with the optimal sensor placement for an electrical impedance tomography experiment to recover the fiber orientation in laminate composites.
An evaluation of the feedback loops in the poverty focus of world bank operations.
Fardoust, Shahrokh; Kanbur, Ravi; Luo, Xubei; Sundberg, Mark
2018-04-01
The World Bank Group in 2013 made the elimination of extreme poverty by 2030 a central institutional focus and purpose. This paper, based on an evaluation conducted by the Independent Evaluation Group of the World Bank Group, examines how, and how well, the Bank uses feedback loops to enhance the poverty focus of its operations. Feedback loops are important for every element of the results chain running from data, to diagnostics, to strategy formulation and finally to strategy implementation. The evaluation uses a range of instruments, including surveys of stakeholders and World Bank staff, focus group meetings, country case studies and systematic reviews of Bank lending and non-lending operations. We find that while the Bank generates useful information on poverty reduction from its projects and programs, the feedback loops - from outcomes to data analysis to diagnostics to strategy formulation and implementation - have generally been weak, with sizable variation across countries. Copyright © 2017 The World Bank. Published by Elsevier Ltd.. All rights reserved.
2015-01-01
Targeting of noncanonical DNA structures, such as hairpin loops, may have significant diagnostic and therapeutic potential. Oligonucleotides can be used for binding to mRNA, forming a DNA/RNA hybrid duplex that inhibits translation. This kind of modulation of gene expression is called the antisense approach. In order to determine the best strategy to target a common structural motif in mRNA, we have designed a set of stem-loop DNA molecules with sequence: d(GCGCTnGTAAT5GTTACTnGCGC), where n = 1, 3, or 5, “T5” is an end loop of five thymines. We used a combination of calorimetric and spectroscopy techniques to determine the thermodynamics for the reaction of a set of hairpins containing internal loops with their respective partially complementary strands. Our aim was to determine if internal- and end-loops are promising regions for targeting with their corresponding complementary strands. Indeed, all targeting reactions were accompanied by negative changes in free energy, indicating that reactions proceed spontaneously. Further investigation showed that these negative free energy terms result from a net balance of unfavorable entropy and favorable enthalpy contributions. In particular, unfolding of hairpins and duplexes is accompanied by positive changes in heat capacity, which may be a result of exposure of hydrophobic groups to the solvent. This study provides a new method for the targeting of mRNA in order to control gene expression. PMID:25486129
Suppressing Transients In Digital Phase-Locked Loops
NASA Technical Reports Server (NTRS)
Thomas, J. B.
1993-01-01
Loop of arbitrary order starts in steady-state lock. Method for initializing variables of digital phase-locked loop reduces or eliminates transients in phase and frequency typically occurring during acquisition of lock on signal or when changes made in values of loop-filter parameters called "loop constants". Enables direct acquisition by third-order loop without prior acquisition by second-order loop of greater bandwidth, and eliminates those perturbations in phase and frequency lock occurring when loop constants changed by arbitrarily large amounts.
Consistent Orientation of Moduli Spaces
NASA Astrophysics Data System (ADS)
Freed, Daniel S.; Hopkins, Michael J.; Teleman, Constantin
In a series of papers by Freed, Hopkins, and Teleman (2003, 2005, 2007a) the relationship between positive energy representations of the loop group of a compact Lie group G and the twisted equivariant K-theory Kτ+dimGG (G) was developed. Here G acts on itself by conjugation. The loop group representations depend on a choice of ‘level’, and the twisting τ is derived from the level. For all levels the main theorem is an isomorphism of abelian groups, and for special transgressed levels it is an isomorphism of rings: the fusion ring of the loop group andKτ+dimGG (G) as a ring. For G connected with π1G torsionfree, it has been proven that the ring Kτ+dimGG (G) is a quotient of the representation ring of G and can be calculated explicitly. In these cases it agrees with the fusion ring of the corresponding centrally extended loop group. This chapter explicates the multiplication on the twisted equivariant K-theory for an arbitrary compact Lie group G. It constructs a Frobenius ring structure on Kτ+dimGG (G). This is best expressed in the language of topological quantum field theory: a two-dimensional topological quantum field theory (TQFT) is constructed over the integers in which the abelian group attached to the circle is Kτ+dimGG (G).
System identification from closed-loop data with known output feedback dynamics
NASA Technical Reports Server (NTRS)
Phan, Minh; Juang, Jer-Nan; Horta, Lucas G.; Longman, Richard W.
1992-01-01
This paper presents a procedure to identify the open loop systems when it is operating under closed loop conditions. First, closed loop excitation data are used to compute the system open loop and closed loop Markov parameters. The Markov parameters, which are the pulse response samples, are then used to compute a state space representation of the open loop system. Two closed loop configurations are considered in this paper. The closed loop system can have either a linear output feedback controller or a dynamic output feedback controller. Numerical examples are provided to illustrate the proposed closed loop identification method.
Perturbative Quantum Gravity from Gauge Theory
NASA Astrophysics Data System (ADS)
Carrasco, John Joseph
In this dissertation we present the graphical techniques recently developed in the construction of multi-loop scattering amplitudes using the method of generalized unitarity. We construct the three-loop and four-loop four-point amplitudes of N = 8 supergravity using these methods and the Kawaii, Lewellen and Tye tree-level relations which map tree-level gauge theory amplitudes to tree-level gravity theory amplitudes. We conclude by extending a tree-level duality between color and kinematics, generic to gauge theories, to a loop level conjecture, allowing the easy relation between loop-level gauge and gravity kinematics. We provide non-trivial evidence for this conjecture at three-loops in the particular case of maximal supersymmetry.
Premeasured Chordal Loops for Mitral Valve Repair.
Gillinov, Marc; Quinn, Reed; Kerendi, Faraz; Gaudiani, Vince; Shemin, Richard; Barnhart, Glenn; Raines, Edward; Gerdisch, Marc W; Banbury, Michael
2016-09-01
Premeasured expanded polytetrafluoroethylene chordal loops with integrated sutures for attachment to the papillary muscle and leaflet edges facilitate correction of mitral valve prolapse. Configured as a group of 3 loops (length range 12 to 24 mm), the loops are attached to a pledget that is passed through the papillary muscle and tied. Each of the loops has 2 sutures with attached needles; these needles are passed through the free edge of the leaflet and then the sutures are tied to each other, securing the chordal loop to the leaflet. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
The design of multirate digital control systems
NASA Technical Reports Server (NTRS)
Berg, M. C.
1986-01-01
The successive loop closures synthesis method is the only method for multirate (MR) synthesis in common use. A new method for MR synthesis is introduced which requires a gradient-search solution to a constrained optimization problem. Some advantages of this method are that the control laws for all control loops are synthesized simultaneously, taking full advantage of all cross-coupling effects, and that simple, low-order compensator structures are easily accomodated. The algorithm and associated computer program for solving the constrained optimization problem are described. The successive loop closures , optimal control, and constrained optimization synthesis methods are applied to two example design problems. A series of compensator pairs are synthesized for each example problem. The succesive loop closure, optimal control, and constrained optimization synthesis methods are compared, in the context of the two design problems.
Stability of beta-titanium T-loop springs preactivated by gradual curvature
Caldas, Sergei Godeiro Fernandes Rabelo; Martins, Renato Parsekian; de Araújo, Marcela Emílio; Galvão, Marília Regalado; da Silva, Roberto Soares; Martins, Lídia Parsekian
2017-01-01
ABSTRACT Objective: Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation. Methods: Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief, by trial activation. The other eight groups were tested after 24, 48 and 72 hours, 1, 2, 4, 8 and 12 weeks, respectively. Using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amount of horizontal force, moment and moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation, in an interbracket distance of 23 mm. Results: The horizontal forces decreased gradually among the groups (p< 0.001) and the moments showed a significant and slow decrease over time among the groups (p< 0.001). All groups produced similar M/F ratios (p= 0.532), with no influence of time. Conclusions: The TLSs preactivated by curvature suffered a gradual deformation over time, which affected the force system, specifically the moments, which affected the horizontal forces produced. PMID:29364381
Radiation Enhanced Absorption of Frank Loops by Nanovoids in Cu
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Youxing; Zhang, Xinghang; Wang, Jian
Neutron and heavy ion irradiation generally induces voids in metallic materials, and continuous radiations typically result in void swelling and mechanical failure of the irradiated materials. Recent experiments showed that nanovoids in nanotwinned copper could act as sinks for radiation-induced Frank loops, significantly mitigating radiation damage [Y. Chen et al., Nat. Commun. 6:7036 (2015)]. In this paper, we report on structural evolution of Frank loops under cascades and address the role of nanovoids in absorbing Frank loops in detail by using molecular dynamics simulations. Results show that a stand-alone Frank loop is stable under cascades. When Frank loops are adjacentmore » to nanovoids, the diffusion of a group of atoms from the loop into nanovoids is accomplished via the formation and propagation of dislocation loops. The loop-nanovoid interactions result in the shrinkage of the nanovoids and the Frank loops.« less
Radiation Enhanced Absorption of Frank Loops by Nanovoids in Cu
Chen, Youxing; Zhang, Xinghang; Wang, Jian
2016-11-01
Neutron and heavy ion irradiation generally induces voids in metallic materials, and continuous radiations typically result in void swelling and mechanical failure of the irradiated materials. Recent experiments showed that nanovoids in nanotwinned copper could act as sinks for radiation-induced Frank loops, significantly mitigating radiation damage [Y. Chen et al., Nat. Commun. 6:7036 (2015)]. In this paper, we report on structural evolution of Frank loops under cascades and address the role of nanovoids in absorbing Frank loops in detail by using molecular dynamics simulations. Results show that a stand-alone Frank loop is stable under cascades. When Frank loops are adjacentmore » to nanovoids, the diffusion of a group of atoms from the loop into nanovoids is accomplished via the formation and propagation of dislocation loops. The loop-nanovoid interactions result in the shrinkage of the nanovoids and the Frank loops.« less
He, Haijun; Shao, Liyang; Qian, Heng; Zhang, Xinpu; Liang, Jiawei; Luo, Bin; Pan, Wei; Yan, Lianshan
2017-03-20
A novel demodulation method for Sagnac loop interferometer based sensor has been proposed and demonstrated, by unwrapping the phase changes with birefringence interrogation. A temperature sensor based on Sagnac loop interferometer has been used to verify the feasibility of the proposed method. Several tests with 40 °C temperature range have been accomplished with a great linearity of 0.9996 in full range. The proposed scheme is universal for all Sagnac loop interferometer based sensors and it has unlimited linear measurable range which overwhelming the conventional demodulation method with peak/dip tracing. Furthermore, the influence of the wavelength sampling interval and wavelength span on the demodulation error has been discussed in this work. The proposed interrogation method has a great significance for Sagnac loop interferometer sensor and it might greatly enhance the availability of this type of sensors in practical application.
Nakashima, Kei; Aoshima, Masahiro; Ohkuni, Yoshihiro; Hoshino, Eri; Hashimoto, Kohei; Otsuka, Yoshihito
2014-12-01
Loop-mediated isothermal amplification (LAMP) is becoming an established nucleic acid amplification method offering rapid, accurate, and cost-effective diagnosis of infectious diseases. We retrospectively evaluated 78 consecutive HIV-uninfected patients who underwent LAMP method for diagnosing Pneumocystis pneumonia (PCP). Diagnosis of PCP was made by the detection of Pneumocystis jirovecii (P. jirovecii) with positive LAMP or conventional staining (CS) (Grocott methenamine silver staining or Diff-Quick™) on the basis of compatible clinical symptoms and radiologic findings. Additionally, we reviewed HIV-uninfected immunocompromised patients who underwent subcontract PCR as a historical control. LAMP was positive in 10 (90.9%) of 11 positive-CS patients. Among 13 negative-CS patients with positive LAMP, 11 (84.6%) had PCP, and the remaining 2 were categorized as having P. jirovecii colonization. LDH levels in negative-CS PCP were higher than in positive-CS PCP (p = 0.026). (1 → 3)-β-D-glucan levels in negative-CS PCP were lower than in positive-CS PCP (p = 0.011). The interval from symptom onset to diagnosis as PCP in LAMP group (3.45 ± 1.77 days; n = 22) was shorter than in subcontract PCR group (6.90 ± 2.28 days; n = 10; p < 0.001). As for patients without PCP, duration of unnecessary PCP treatment in LAMP group (2; 2-3 days; n = 10) was shorter than in subcontract PCR group (7; 7-12.25 days; n = 6; p = 0.003). LAMP showed higher sensitivity (95.4%) and positive predictive value (91.3%) than subcontract PCR did. Pneumocystis LAMP method is a sensitive and cost-effective diagnostic method and is easy to administer in general hospitals. In-house LAMP method would realize early diagnosis of PCP, resulting in improving PCP prognosis and reducing unnecessary PCP-specific treatment. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Presenting simulation results in a nested loop plot.
Rücker, Gerta; Schwarzer, Guido
2014-12-12
Statisticians investigate new methods in simulations to evaluate their properties for future real data applications. Results are often presented in a number of figures, e.g., Trellis plots. We had conducted a simulation study on six statistical methods for estimating the treatment effect in binary outcome meta-analyses, where selection bias (e.g., publication bias) was suspected because of apparent funnel plot asymmetry. We varied five simulation parameters: true treatment effect, extent of selection, event proportion in control group, heterogeneity parameter, and number of studies in meta-analysis. In combination, this yielded a total number of 768 scenarios. To present all results using Trellis plots, 12 figures were needed. Choosing bias as criterion of interest, we present a 'nested loop plot', a diagram type that aims to have all simulation results in one plot. The idea was to bring all scenarios into a lexicographical order and arrange them consecutively on the horizontal axis of a plot, whereas the treatment effect estimate is presented on the vertical axis. The plot illustrates how parameters simultaneously influenced the estimate. It can be combined with a Trellis plot in a so-called hybrid plot. Nested loop plots may also be applied to other criteria such as the variance of estimation. The nested loop plot, similar to a time series graph, summarizes all information about the results of a simulation study with respect to a chosen criterion in one picture and provides a suitable alternative or an addition to Trellis plots.
A novel system for automated propofol sedation: hybrid sedation system (HSS).
Zaouter, Cedrick; Taddei, Riccardo; Wehbe, Mohamad; Arbeid, Erik; Cyr, Shantale; Giunta, Francesco; Hemmerling, Thomas M
2017-04-01
Closed-loop systems for propofol have been demonstrated to be safe and reliable for general anesthesia. However, no study has been conducted using a closed-loop system specifically designed for sedation in patients under spinal anesthesia. We developed an automatic anesthesia sedation system that allows for closed-loop delivery of propofol for sedation integrating a decision support system, called the hybrid sedation system (HSS). The objective of this study is to compare this system with standard practice. One hundred fifty patients were enrolled and randomly assigned to two groups: HSS-Group (N = 75), in which propofol was administered using a closed-loop system; Control Group (N = 75), in which propofol was delivered manually. The clinical performance of the propofol sedation control is defined as efficacy to maintain bispectral index (BIS) near 65. The clinical control was called 'Excellent', 'Good', 'Poor' and 'Inadequate' with BIS values within 10 %, from 11 to 20 %, 21 to 30 %, or greater than 30 % of the BIS target of 65, respectively. The controller performance was evaluated using Varvel's parameters. Data are presented as mean ± standard deviation, groups were compared using t test or Chi square test, P < 0.05. Clinical performance of sedation showed 'Excellent' control in the HSS-group for a significantly longer period of time (49 vs. 26 % in the control group, P < 0.0001). 'Poor' and 'Inadequate' sedation was significantly shorter in the HSS Group compared to the Control Group (11 and 10 % vs. 20 and 18 %, respectively, P < 0.0001). The novel, closed-loop system for propofol sedation showed better maintenance of the target BIS value compared to manual administration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ranieri, M.G.A., E-mail: gabi.ranieri@ig.com.br; Aguiar, E.C.; Cilense, M.
Highlights: • Bi{sub 4}Ti{sub 3}O{sub 12} thick films were obtained by SSR and PPM methods. • Both systems crystallize in an orthorhombic structure. • Textured characteristics were evidenced. • Grain morphology affects the P–E loops. - Abstract: Bismuth titanate powders (Bi{sub 4}Ti{sub 3}O{sub 12}-BIT) were fabricated by solid state reaction (SSR) and polymeric precursor method (PPM). From these powders, Bi{sub 4}Ti{sub 3}O{sub 12} pellets were obtained by tape-casting using plate-like templates particles prepared by a molten salt method. The BIT phase crystallizes in an orthorhombic structure type with space group Fmmm. Agglomeration of the particles, which affects the densification ofmore » the ceramic, electrical conduction and leakage current at high electric fields, was monitored by transmission electronic microscopy (TEM) analyses. FEG-SEM indicated that different shape of grains of BIT ceramics was influenced by the processing route. Both SSR and PPM methods lead to unsaturated P–E loops of BIT ceramics originating from the highly c-axis orientation and high conductivity which was affected by charge carriers flowing normally to the grain boundary of the crystal lattice.« less
Laser beam pulse formatting method
Daly, T.P.; Moses, E.I.; Patterson, R.W.; Sawicki, R.H.
1994-08-09
A method for formatting a laser beam pulse using one or more delay loops is disclosed. The delay loops have a partially reflective beam splitter and a plurality of highly reflective mirrors arranged such that the laser beam pulse enters into the delay loop through the beam splitter and circulates therein along a delay loop length defined by the mirrors. As the laser beam pulse circulates within the delay loop a portion thereof is emitted upon each completed circuit when the laser beam pulse strikes the beam splitter. The laser beam pulse is thereby formatted into a plurality of sub-pulses. The delay loops are used in combination to produce complex waveforms by combining the sub-pulses using additive waveform synthesis. 8 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stimpson, Shane; Collins, Benjamin; Kochunas, Brendan
The MPACT code, being developed collaboratively by the University of Michigan and Oak Ridge National Laboratory, is the primary deterministic neutron transport solver being deployed within the Virtual Environment for Reactor Applications (VERA) as part of the Consortium for Advanced Simulation of Light Water Reactors (CASL). In many applications of the MPACT code, transport-corrected scattering has proven to be an obstacle in terms of stability, and considerable effort has been made to try to resolve the convergence issues that arise from it. Most of the convergence problems seem related to the transport-corrected cross sections, particularly when used in the 2Dmore » method of characteristics (MOC) solver, which is the focus of this work. Here in this paper, the stability and performance of the 2-D MOC solver in MPACT is evaluated for two iteration schemes: Gauss-Seidel and Jacobi. With the Gauss-Seidel approach, as the MOC solver loops over groups, it uses the flux solution from the previous group to construct the inscatter source for the next group. Alternatively, the Jacobi approach uses only the fluxes from the previous outer iteration to determine the inscatter source for each group. Consequently for the Jacobi iteration, the loop over groups can be moved from the outermost loop$-$as is the case with the Gauss-Seidel sweeper$-$to the innermost loop, allowing for a substantial increase in efficiency by minimizing the overhead of retrieving segment, region, and surface index information from the ray tracing data. Several test problems are assessed: (1) Babcock & Wilcox 1810 Core I, (2) Dimple S01A-Sq, (3) VERA Progression Problem 5a, and (4) VERA Problem 2a. The Jacobi iteration exhibits better stability than Gauss-Seidel, allowing for converged solutions to be obtained over a much wider range of iteration control parameters. Additionally, the MOC solve time with the Jacobi approach is roughly 2.0-2.5× faster per sweep. While the performance and stability of the Jacobi iteration are substantially improved compared to the Gauss-Seidel iteration, it does yield a roughly 8$-$10% increase in the overall memory requirement.« less
Stimpson, Shane; Collins, Benjamin; Kochunas, Brendan
2017-03-10
The MPACT code, being developed collaboratively by the University of Michigan and Oak Ridge National Laboratory, is the primary deterministic neutron transport solver being deployed within the Virtual Environment for Reactor Applications (VERA) as part of the Consortium for Advanced Simulation of Light Water Reactors (CASL). In many applications of the MPACT code, transport-corrected scattering has proven to be an obstacle in terms of stability, and considerable effort has been made to try to resolve the convergence issues that arise from it. Most of the convergence problems seem related to the transport-corrected cross sections, particularly when used in the 2Dmore » method of characteristics (MOC) solver, which is the focus of this work. Here in this paper, the stability and performance of the 2-D MOC solver in MPACT is evaluated for two iteration schemes: Gauss-Seidel and Jacobi. With the Gauss-Seidel approach, as the MOC solver loops over groups, it uses the flux solution from the previous group to construct the inscatter source for the next group. Alternatively, the Jacobi approach uses only the fluxes from the previous outer iteration to determine the inscatter source for each group. Consequently for the Jacobi iteration, the loop over groups can be moved from the outermost loop$-$as is the case with the Gauss-Seidel sweeper$-$to the innermost loop, allowing for a substantial increase in efficiency by minimizing the overhead of retrieving segment, region, and surface index information from the ray tracing data. Several test problems are assessed: (1) Babcock & Wilcox 1810 Core I, (2) Dimple S01A-Sq, (3) VERA Progression Problem 5a, and (4) VERA Problem 2a. The Jacobi iteration exhibits better stability than Gauss-Seidel, allowing for converged solutions to be obtained over a much wider range of iteration control parameters. Additionally, the MOC solve time with the Jacobi approach is roughly 2.0-2.5× faster per sweep. While the performance and stability of the Jacobi iteration are substantially improved compared to the Gauss-Seidel iteration, it does yield a roughly 8$-$10% increase in the overall memory requirement.« less
Double closed-loop cascade control for lower limb exoskeleton with elastic actuation.
Zhu, Yanhe; Zheng, Tianjiao; Jin, Hongzhe; Yang, Jixing; Zhao, Jie
2015-01-01
Unlike traditional rigid actuators, the significant features of Series Elastic Actuator (SEA) are stable torque control, lower output impedance, impact resistance and energy storage. Recently, SEA has been applied in many exoskeletons. In such applications, a key issue is how to realize the human-exoskeleton movement coordination. In this paper, double closed-loop cascade control for lower limb exoskeleton with SEA is proposed. This control method consists of inner SEA torque loop and outer contact force loop. Utilizing the SEA torque control with a motor velocity loop, actuation performances of SEA are analyzed. An integrated exoskeleton control system is designed, in which joint angles are calculated by internal encoders and resolvers and contact forces are gathered by external pressure sensors. The double closed-loop cascade control model is established based on the feedback signals of internal and external sensor. Movement experiments are accomplished in our prototype of lower limb exoskeleton. Preliminary results indicate the exoskeleton movements with pilot can be realized stably by utilizing this double closed-loop cascade control method. Feasibility of the SEA in our exoskeleton robot and effectiveness of the control method are verified.
Fabrication techniques for superconducting readout loops
NASA Technical Reports Server (NTRS)
Payne, J. E.
1982-01-01
Procedures for the fabrication of superconducting readout loops out of niobium on glass substrates were developed. A computer program for an existing fabrication system was developed. Both positive and negative resist procedures for the production of the readout loops were investigated. Methods used to produce satisfactory loops are described and the various parameters affecting the performance of the loops are analyzed.
Chemically controlled closed-loop insulin delivery.
Ravaine, Valérie; Ancla, Christophe; Catargi, Bogdan
2008-11-24
Alternative treatments for diabetes are currently being investigated to improve both patient comfort and avoid complications due to hyperglycaemia episodes. In the absence of a cure like pancreas or beta-islets transplants, the ideal method would be an artificial "closed-loop" system able to mimic pancreas activity. This would operate continuously and automatically, causing appropriate response to losses and gains in glucose levels. Chemically controlled closed-loop insulin delivery has been explored by two main strategies. The first one consists in delivering insulin with a glucose-responsive matrix. Polymeric hydrogels that swell or shrink according to the glucose concentration allow delivering insulin doses adapted to the glucose concentration. The second strategy consists in modifying insulin itself with glucose-sensitive functional groups that trigger its activity. Recent developments made in these areas represent significant progress in terms of biocompatibility, selectivity, pharmacokinetics, and easiness of administration, as required for in vivo applications. Although some issues still have to be overcome, this field of research is promising as a possible alternative to other approaches for diabetes treatment.
Ding, Mingnan; Lu, Bing-Sui; Xing, Xiangjun
2016-10-01
Self-consistent field theory (SCFT) is used to study the mean potential near a charged plate inside a m:-n electrolyte. A perturbation series is developed in terms of g=4πκb, where band1/κ are Bjerrum length and bare Debye length, respectively. To the zeroth order, we obtain the nonlinear Poisson-Boltzmann theory. For asymmetric electrolytes (m≠n), the first order (one-loop) correction to mean potential contains a secular term, which indicates the breakdown of the regular perturbation method. Using a renormalizaton group transformation, we remove the secular term and obtain a globally well-behaved one-loop approximation with a renormalized Debye length and a renormalized surface charge density. Furthermore, we find that if the counterions are multivalent, the surface charge density is renormalized substantially downwards and may undergo a change of sign, if the bare surface charge density is sufficiently large. Our results agrees with large MC simulation even when the density of electrolytes is relatively high.
NASA Technical Reports Server (NTRS)
Lee, Kimyeong; Holman, Richard; Kolb, Edward W.
1987-01-01
Wilson-loop symmetry breaking is considered on a space-time of the form M4 x K, where M4 is a four-dimensional space-time and K is an internal space with nontrivial and finite fundamental group. It is shown in a simple model that the different vacua obtained by breaking a non-Abelian gauge group by Wilson loops are separated in the space of gauge potentials by a finite energy barrier. An interpolating gauge configuration is then constructed between these vacua and shown to have minimum energy. Finally some implications of this construction are discussed.
A low noise and ultra-narrow bandwidth frequency-locked loop based on the beat method.
Gao, Wei; Sui, Jianping; Chen, Zhiyong; Yu, Fang; Sheng, Rongwu
2011-06-01
A novel frequency-locked loop (FLL) based on the beat method is proposed in this paper. Compared with other frequency feedback loops, this FLL is a digital loop with simple structure and very low noise. As shown in the experimental results, this FLL can be used to reduce close-in phase noise on atomic frequency standards, through which a composite frequency standard with ultra-low phase noise and low cost can be easily realized.
A group theoretic method for string loop diagram
NASA Astrophysics Data System (ADS)
Neveu, A.; West, P.
1987-08-01
The new approach to arbitrary string scattering proposed by the authors is used to compute the planar tadpole operator, including its measure, for the open bosonic string. The Virasoro gauge identities play a crucial role and are found to contain in general anomalous terms for open strings. Permanent address: Mathematics Department, King's College, London WC2R 2LS, UK.
Stabilizing an optoelectronic microwave oscillator with photonic filters
NASA Technical Reports Server (NTRS)
Strekalov, D.; Aveline, D.; Yu, N.; Thompson, R.; Matsko, A. B.; Maleki, L.
2003-01-01
This paper compares methods of active stabilization of an optoelectronic microwave oscillator (OEO) based on insertion of a source of optical group delay into an OEO loop. The performance of an OEO stabilized with either a high- optical cavity or an atomic cell is analyzed. We show that the elements play a role of narrow-band microwave filters improving an OEO stability.
Thermal management systems and methods
Gering, Kevin L.; Haefner, Daryl R.
2006-12-12
A thermal management system for a vehicle includes a heat exchanger having a thermal energy storage material provided therein, a first coolant loop thermally coupled to an electrochemical storage device located within the first coolant loop and to the heat exchanger, and a second coolant loop thermally coupled to the heat exchanger. The first and second coolant loops are configured to carry distinct thermal energy transfer media. The thermal management system also includes an interface configured to facilitate transfer of heat generated by an internal combustion engine to the heat exchanger via the second coolant loop in order to selectively deliver the heat to the electrochemical storage device. Thermal management methods are also provided.
Paulos, Renata Gregorio; Rudelli, Bruno Alves; Filippe, Renee Zon; dos Santos, Gustavo Bispo; Herrera, Ana Abarca; Ribeiro, Andre Araujo; de Rezende, Marcelo Rosa; Hsiang-Wei, Teng; Mattar-Jr, Rames
2017-01-01
OBJECTIVES: To analyze the histological changes observed in venous grafts subjected to arterial blood flow as a function of the duration of the postoperative period to optimize their use in free flap reconstructions. METHOD: Twenty-five rats (7 females and 18 males) underwent surgery. Surgeries were performed on one animal per week. Five weeks after the first surgery, the same five animals were subjected to an additional surgery to assess the presence or absence of blood flow through the vascular loop, and samples were collected for histological analysis. This cycle was performed five times. RESULTS: Of the rats euthanized four to five weeks after the first surgery, no blood flow was observed through the graft in 80% of the cases. In the group euthanized three weeks after the first surgery, no blood flow was observed in 20% of the cases. In the groups euthanized one to two weeks after the first surgery, blood flow through the vascular loop was observed in all animals. Moreover, intimal proliferation tended to increase with the duration of the postoperative period. Two weeks after surgery, intimal proliferation increased slightly, whereas strong intimal proliferation was observed in all rats evaluated five weeks after surgery. CONCLUSION: Intimal proliferation was the most significant change noted in venous grafts as a function of the duration of the postoperative period and was directly correlated with graft occlusion. In cases in which vascular loops are required during free flap reconstruction, both procedures should preferably be performed during the same surgery. PMID:29069256
NASA Technical Reports Server (NTRS)
Thomas, Jr., Jess B. (Inventor)
1991-01-01
An improved digital phase lock loop incorporates several distinctive features that attain better performance at high loop gain and better phase accuracy. These features include: phase feedback to a number-controlled oscillator in addition to phase rate; analytical tracking of phase (both integer and fractional cycles); an amplitude-insensitive phase extractor; a more accurate method for extracting measured phase; a method for changing loop gain during a track without loss of lock; and a method for avoiding loss of sampled data during computation delay, while maintaining excellent tracking performance. The advantages of using phase and phase-rate feedback are demonstrated by comparing performance with that of rate-only feedback. Extraction of phase by the method of modeling provides accurate phase measurements even when the number-controlled oscillator phase is discontinuously updated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
El-Atwani, O.; Esquivel, E.; Efe, M.
Displacement damage, through heavy ion irradiation was studied on two tungsten grades (coarse grained tungsten (CGW) and nanocrystalline and ultrafine grained tungsten (NCW)) using different displacement per atom rates and different irradiation temperatures (RT and 1050 K). Percentage of <111> and <100> type loops at the irradiation conditions was determined. Irradiation damage in the microstructure was quantified using average loop areas and densities (method A) and loop areal fraction in the grain matrices under 2-beam diffraction conditions (method B). Average values of <111> and <100> loops were calculated from method A. Loop coalescence was shown to occur for CGW atmore » 0.25 dpa. Using both methods of quantifying microstructural damage, no effect of dpa rate was observed and damage in CGW was shown to be the same at RT and 1050 K. Swelling from voids observed at 1050 K was quantified. The loop damage in NCW was compared to CGW at the same diffraction and imaging conditions. NCW was shown to possess enhanced irradiation resistance at RT regarding loop damage and higher swelling resistance at 1050 K compared to CGW. For irradiation at 1050 K, the NCW was shown to have a similar defect densities to the CGW which is attributed to higher surface effects in the CGW, vacancy loop growth to voids and a better sink efficiency in the CGW deduced from the vacancy distribution profiles from Kinetic Monte Carlo simulations. Loop density and swelling was shown to have similar values in grains sizes that range from 80-600 nm. No loop or void denuded zones occurred at any of the irradiation conditions. This work has a collection of experiments and conclusions that are of vital importance to materials and nuclear communities.« less
El-Atwani, O.; Esquivel, E.; Efe, M.; ...
2018-02-20
Displacement damage, through heavy ion irradiation was studied on two tungsten grades (coarse grained tungsten (CGW) and nanocrystalline and ultrafine grained tungsten (NCW)) using different displacement per atom rates and different irradiation temperatures (RT and 1050 K). Percentage of <111> and <100> type loops at the irradiation conditions was determined. Irradiation damage in the microstructure was quantified using average loop areas and densities (method A) and loop areal fraction in the grain matrices under 2-beam diffraction conditions (method B). Average values of <111> and <100> loops were calculated from method A. Loop coalescence was shown to occur for CGW atmore » 0.25 dpa. Using both methods of quantifying microstructural damage, no effect of dpa rate was observed and damage in CGW was shown to be the same at RT and 1050 K. Swelling from voids observed at 1050 K was quantified. The loop damage in NCW was compared to CGW at the same diffraction and imaging conditions. NCW was shown to possess enhanced irradiation resistance at RT regarding loop damage and higher swelling resistance at 1050 K compared to CGW. For irradiation at 1050 K, the NCW was shown to have a similar defect densities to the CGW which is attributed to higher surface effects in the CGW, vacancy loop growth to voids and a better sink efficiency in the CGW deduced from the vacancy distribution profiles from Kinetic Monte Carlo simulations. Loop density and swelling was shown to have similar values in grains sizes that range from 80-600 nm. No loop or void denuded zones occurred at any of the irradiation conditions. This work has a collection of experiments and conclusions that are of vital importance to materials and nuclear communities.« less
Hutsuliak, A I
2016-08-01
In the experiment on 50 rabbits cholecysto-entero and entero-entero anastomoses were formed on intestinal Roux loop. In 35 animals (the main group) a single layer evert- ing anastomoses by using high frequence (HF) electric welding method were formed, in 15 (the comparison group) single row suture anastomoses has been done. The anas- tomosis sufficiency were performed by using hydropressure, pneumopressure meth- ods and breakload test. It was established that all anastomoses formed by HF-electric welding method were passable and hermetic, also had strong sufficiency. Strength of weld joint in the postoperative period increased in a linear progression and after 3 weeks almost reached strength intact intestine (240-250 mm Hg).
Looping: Supporting Student Learning through Long-Term Relationships.
ERIC Educational Resources Information Center
Northeast and Islands Regional Educational Lab. at Brown Univ., Providence, RI.
Looping refers to the increasingly common practice of keeping groups of students together for two or more years with the same teacher. This booklet, first in a series of "Themes in Education" provides information on the educational practice of looping and includes selected current references on the topic. The booklet outlines the history of this…
NASA Astrophysics Data System (ADS)
Siscoe, G. L.
2012-12-01
What is a system? A group of elements interacting with each other so as to create feedback loops. A system gets complex as the number of feedback loops increases and as the feedback loops exhibit time delays. Positive and negative feedback loops with time delays can give a system intrinsic time dependence and emergent properties. A system generally has input and output flows of something (matter, energy, money), which, if time variable, add an extrinsic component to its behavior. The magnetosphere is a group of elements interacting through feedback loops, some with time delays, driven by energy and mass inflow from a variable solar wind and outflow into the atmosphere and solar wind. The magnetosphere is a complex system. With no solar wind, there is no behavior. With solar wind, there is behavior from intrinsic and extrinsic causes. As a contribution to taking a macroscopic view of magnetospheric dynamics, to treating the magnetosphere as a globally integrated, complex entity, I will discus the magnetosphere as a system, its feedback loops, time delays, emergent behavior, and intrinsic and extrinsic behavior modes.
NASA Astrophysics Data System (ADS)
Ishikawa, Kaoru; Nakamura, Taro; Osumi, Hisashi
A reliable control method is proposed for multiple loop control system. After a feedback loop failure, such as case of the sensor break down, the control system becomes unstable and has a big fluctuation even if it has a disturbance observer. To cope with this problem, the proposed method uses an equivalent transfer function (ETF) as active redundancy compensation after the loop failure. The ETF is designed so that it does not change the transfer function of the whole system before and after the loop failure. In this paper, the characteristic of reliable control system that uses an ETF and a disturbance observer is examined by the experiment that uses the DC servo motor for the current feedback loop failure in the position servo system.
Deliver a set of tools for resolving bad inductive loops and correcting bad data.
DOT National Transportation Integrated Search
2012-04-01
This project prototyped and demonstrated procedures to find and mitigate loop detector errors, and to derive more valuable data from loops. Specifically, methods were developed to find and isolate out loop data which is "bad" or invalid, so that miti...
Deliver a set of tools for resolving bad inductive loops and correcting bad data
DOT National Transportation Integrated Search
2012-04-10
This project prototyped and demonstrated procedures to find and mitigate loop detector errors, and to derive more valuable data from loops. Specifically, methods were developed to find and isolate out loop data which is "bad" or invalid, so that miti...
Preliminary demonstration of a robust controller design method
NASA Technical Reports Server (NTRS)
Anderson, L. R.
1980-01-01
Alternative computational procedures for obtaining a feedback control law which yields a control signal based on measurable quantitites are evaluated. The three methods evaluated are: (1) the standard linear quadratic regulator design model; (2) minimization of the norm of the feedback matrix, k via nonlinear programming subject to the constraint that the closed loop eigenvalues be in a specified domain in the complex plane; and (3) maximize the angles between the closed loop eigenvectors in combination with minimizing the norm of K also via the constrained nonlinear programming. The third or robust design method was chosen to yield a closed loop system whose eigenvalues are insensitive to small changes in the A and B matrices. The relationship between orthogonality of closed loop eigenvectors and the sensitivity of closed loop eigenvalues is described. Computer programs are described.
Biomechanical performance of different cable and wire cerclage configurations.
Lenz, Mark; Perren, Stephan Marcel; Richards, Robert Geoff; Mückley, Thomas; Hofmann, Gunther Olaf; Gueorguiev, Boyko; Windolf, Markus
2013-01-01
Cerclage technology is regaining interest due to the increasing number of periprosthetic fractures. Different wiring techniques have been formerly proposed and have hibernated over years. Hereby, they are compared to current cerclage technology. Seven groups (n = 6) of different cable cerclage (Ø1.7 mm, crimp closure) configurations (one single cerclage looped once around the shells, one single cerclage looped twice, two cerclages each looped once) and solid wire cerclages (Ø1.5 mm, twist closure) (same configurations as cable cerclages, and two braided wires, twisted around each other looped once) fixed two cortical half shells of human femoral shaft mounted on a testing jig. Sinusoidal cyclic loading with constantly increasing force (0.1 N/cycle) was applied starting at 50 N peak load. Cerclage pretension (P), load leading to onset of plastic deformation (D) and load at total failure (T) were identified. Statistical differences between the groups were detected by univariate ANOVA. Double looped cables (P442N ± 129; D1334N ± 319; T2734N ± 330) performed significantly better (p < 0.05) than single looped cables (P292N ± 56; D646N ± 108; T1622N ± 171) and were comparable to two single cables (P392N ± 154; D1191N ± 334; T2675N ± 361). Double looped wires (P335N ± 49; D752N ± 119; T1359N ± 80) were significantly better (p < 0.05) than single looped wires (P181N ± 16; D343N ± 33; T606N ± 109) and performed similarly to single looped cables. Braided wires (P119N ± 26; D225N ± 55; T919N ± 197) exhibited early loss of pretension and plastic deformation. Double looped cerclages provided a better fixation stability compared to a single looped cerclage. Double looped wires were comparable to a single looped cable. The use of braided wires could not be recommended mechanically.
PyR@TE 2: A Python tool for computing RGEs at two-loop
NASA Astrophysics Data System (ADS)
Lyonnet, F.; Schienbein, I.
2017-04-01
Renormalization group equations are an essential tool for the description of theories across different energy scales. Even though their expressions at two-loop for an arbitrary gauge field theory have been known for more than thirty years, deriving the full set of equations for a given model by hand is very challenging and prone to errors. To tackle this issue, we have introduced in Lyonnet et al. (2014) a Python tool called PyR@TE; Python Renormalization group equations @ Two-loop for Everyone. With PyR@TE, it is easy to implement a given Lagrangian and derive the complete set of two-loop RGEs for all the parameters of the theory. In this paper, we present the new version of this code, PyR@TE 2, which brings many new features and in particular it incorporates kinetic mixing when several U(1) gauge groups are involved. In addition, the group theory part has been greatly improved as we introduced a new Python module dubbed PyLie that deals with all the group theoretical aspects required for the calculation of the RGEs as well as providing very useful model building capabilities. This allows the use of any irreducible representation of the SU(n) , SO(2 n) and SO(2n + 1) groups. Furthermore, it is now possible to implement terms in the Lagrangian involving fields which can be contracted into gauge singlets in more than one way. As a byproduct, results for a popular model (SM + complex triplet) for which, to our knowledge, the complete set of two-loop RGEs has not been calculated before are presented in this paper. Finally, the two-loop RGEs for the anomalous dimension of the scalar and fermion fields have been implemented as well. It is now possible to export the coupled system of beta functions into a numerical C++ function, leading to a consequent speed up in solving them.
Vozeh, S; Steimer, J L
1985-01-01
The concept of feedback control methods for drug dosage optimisation is described from the viewpoint of control theory. The control system consists of 5 parts: (a) patient (the controlled process); (b) response (the measured feedback); (c) model (the mathematical description of the process); (d) adaptor (to update the parameters); and (e) controller (to determine optimum dosing strategy). In addition to the conventional distinction between open-loop and closed-loop control systems, a classification is proposed for dosage optimisation techniques which distinguishes between tight-loop and loose-loop methods depending on whether physician's interaction is absent or included as part of the control step. Unlike engineering problems where the process can usually be controlled by fully automated devices, therapeutic situations often require that the physician be included in the decision-making process to determine the 'optimal' dosing strategy. Tight-loop and loose-loop methods can be further divided into adaptive and non-adaptive, depending on the presence of the adaptor. The main application areas of tight-loop feedback control methods are general anaesthesia, control of blood pressure, and insulin delivery devices. Loose-loop feedback methods have been used for oral anticoagulation and in therapeutic drug monitoring. The methodology, advantages and limitations of the different approaches are reviewed. A general feature common to all application areas could be observed: to perform well under routine clinical conditions, which are characterised by large interpatient variability and sometimes also intrapatient changes, control systems should be adaptive. Apart from application in routine drug treatment, feedback control methods represent an important research tool. They can be applied for the investigation of pathophysiological and pharmacodynamic processes. A most promising application is the evaluation of the relationship between an intermediate response (e.g. drug level), which is often used as feedback for dosage adjustment, and the final therapeutic goal.
New class of two-loop neutrino mass models with distinguishable phenomenology
NASA Astrophysics Data System (ADS)
Cao, Qing-Hong; Chen, Shao-Long; Ma, Ernest; Yan, Bin; Zhang, Dong-Ming
2018-04-01
We discuss a new class of neutrino mass models generated in two loops, and explore specifically three new physics scenarios: (A) doubly charged scalar, (B) dark matter, and (C) leptoquark and diquark, which are verifiable at the 14 TeV LHC Run-II. We point out how the different Higgs insertions will distinguish our two-loop topology with others if the new particles in the loop are in the simplest representations of the SM gauge group.
Pilot-in-the-Loop CFD Method Development
2015-10-31
Contract # N00014-14-C-0020 Pilot-in-the-Loop CFD Method Development Progress Report (CDRL A001) Progress Report for Period: Aug 1, 2015 to...30-10-2015 4. TITLE AND SUBTITLE Pilot-in-the-Loop CFD Method Development 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...environment. For example, ship airwake are calculated using CFD solutions without the presence of the helicopter main rotor. The gusts from the turbulent
Loop equations and bootstrap methods in the lattice
Anderson, Peter D.; Kruczenski, Martin
2017-06-17
Pure gauge theories can be formulated in terms of Wilson Loops by means of the loop equation. In the large-N limit this equation closes in the expectation value of single loops. In particular, using the lattice as a regulator, it becomes a well defined equation for a discrete set of loops. In this paper we study different numerical approaches to solving this equation.
Combined hairpin-antisense compositions and methods for modulating expression
Shanklin, John; Nguyen, Tam
2014-08-05
A nucleotide construct comprising a nucleotide sequence that forms a stem and a loop, wherein the loop comprises a nucleotide sequence that modulates expression of a target, wherein the stem comprises a nucleotide sequence that modulates expression of a target, and wherein the target modulated by the nucleotide sequence in the loop and the target modulated by the nucleotide sequence in the stem may be the same or different. Vectors, methods of regulating target expression, methods of providing a cell, and methods of treating conditions comprising the nucleotide sequence are also disclosed.
Combined hairpin-antisense compositions and methods for modulating expression
Shanklin, John; Nguyen, Tam Huu
2015-11-24
A nucleotide construct comprising a nucleotide sequence that forms a stem and a loop, wherein the loop comprises a nucleotide sequence that modulates expression of a target, wherein the stem comprises a nucleotide sequence that modulates expression of a target, and wherein the target modulated by the nucleotide sequence in the loop and the target modulated by the nucleotide sequence in the stem may be the same or different. Vectors, methods of regulating target expression, methods of providing a cell, and methods of treating conditions comprising the nucleotide sequence are also disclosed.
A systematic and efficient method to compute multi-loop master integrals
NASA Astrophysics Data System (ADS)
Liu, Xiao; Ma, Yan-Qing; Wang, Chen-Yu
2018-04-01
We propose a novel method to compute multi-loop master integrals by constructing and numerically solving a system of ordinary differential equations, with almost trivial boundary conditions. Thus it can be systematically applied to problems with arbitrary kinematic configurations. Numerical tests show that our method can not only achieve results with high precision, but also be much faster than the only existing systematic method sector decomposition. As a by product, we find a new strategy to compute scalar one-loop integrals without reducing them to master integrals.
Encapsulation of Mesenchymal Stem Cells Improves Vascularization of Alginate-Based Scaffolds.
Steiner, Dominik; Lingens, Lara; Fischer, Laura; Köhn, Katrin; Detsch, Rainer; Boccaccini, Aldo R; Fey, Tobias; Greil, Peter; Weis, Christian; Beier, Justus P; Horch, Raymund E; Arkudas, Andreas
2018-05-09
Vascularization of bioartificial tissues can be significantly enhanced by the generation of an arteriovenous (AV) loop. Besides the surgical vascularization, the choice of the scaffold and the applied cells are indispensable cofactors. The combination of alginate dialdehyde and gelatin (ADA-GEL) and mesenchymal stem cells (MSCs) is a promising approach with regard to biocompatibility, biodegradation, as well as de novo tissue formation. In this study, we targeted the investigation of the vascularization of ADA-GEL with and in the absence of encapsulated MSCs in the AV loop model. A Teflon chamber filled with ADA-GEL microcapsules was placed in the groin of Lewis rats and an AV loop was placed into the chamber. Group A encompassed the ADA-GEL without MSCs, whereas group B contained 2 × 10 6 DiI-labeled MSCs/mL ADA-GEL. Four weeks postoperatively, tissue formation and vascularization were investigated by histology and microcomputed tomography. We were able to prove vascularization originating from the AV loop in both groups with statistically significant more vessels in group B containing MSCs. Moreover, encapsulated MSCs promoted biodegradation of the ADA-GEL microcapsules. In the present study, we were able to demonstrate for the first time, the successful vascularization of ADA-GEL microcapsules by means of the AV loop. Furthermore, ADA-GEL displayed a good biocompatibility and encapsulation of MSCs into ADA-GEL microcapsule-enhanced vascularization as well as biodegradation.
Hamada, Megumi; Koda, Keiko
2011-04-01
Although the role of the phonological loop in word-retention is well documented, research in Chinese character retention suggests the involvement of non-phonological encoding. This study investigated whether the extent to which the phonological loop contributes to learning and remembering visually introduced words varies between college-level Chinese ESL learners (N = 20) and native speakers of English (N = 20). The groups performed a paired associative learning task under two conditions (control versus articulatory suppression) with two word types (regularly spelled versus irregularly spelled words) differing in degree of phonological accessibility. The results demonstrated that both groups' recall declined when the phonological loop was made less available (with irregularly spelled words and in the articulatory suppression condition), but the decline was greater for the native group. These results suggest that word learning entails phonological encoding uniformly across learners, but the contribution of phonology varies among learners with diverse linguistic backgrounds.
2011-01-01
Introduction A consequence of knee joint osteoarthritis (OA) is an inability to fully activate the quadriceps muscles, a problem termed arthrogenic muscle inhibition (AMI). AMI leads to marked quadriceps weakness that impairs physical function and may hasten disease progression. The purpose of the present study was to determine whether γ-loop dysfunction contributes to AMI in people with knee joint OA. Methods Fifteen subjects with knee joint OA and 15 controls with no history of knee joint pathology participated in this study. Quadriceps and hamstrings peak isometric torque (Nm) and electromyography (EMG) amplitude were collected before and after 20 minutes of 50 Hz vibration applied to the infrapatellar tendon. Between-group differences in pre-vibration torque were analysed using a one-way analysis of covariance, with age, gender and body mass (kg) as the covariates. If the γ-loop is intact, vibration should decrease torque and EMG levels in the target muscle; if dysfunctional, then torque and EMG levels should not change following vibration. One-sample t tests were thus undertaken to analyse whether percentage changes in torque and EMG differed from zero after vibration in each group. In addition, analyses of covariance were utilised to analyse between-group differences in the percentage changes in torque and EMG following vibration. Results Pre-vibration quadriceps torque was significantly lower in the OA group compared with the control group (P = 0.005). Following tendon vibration, quadriceps torque (P < 0.001) and EMG amplitude (P ≤0.001) decreased significantly in the control group but did not change in the OA group (all P > 0.299). Hamstrings torque and EMG amplitude were unchanged in both groups (all P > 0.204). The vibration-induced changes in quadriceps torque and EMG were significantly different between the OA and control groups (all P < 0.011). No between-group differences were observed for the change in hamstrings torque or EMG (all P > 0.554). Conclusions γ-loop dysfunction may contribute to AMI in individuals with knee joint OA, partially explaining the marked quadriceps weakness and atrophy that is often observed in this population. PMID:21933392
Total Variation with Overlapping Group Sparsity for Image Deblurring under Impulse Noise
Liu, Gang; Huang, Ting-Zhu; Liu, Jun; Lv, Xiao-Guang
2015-01-01
The total variation (TV) regularization method is an effective method for image deblurring in preserving edges. However, the TV based solutions usually have some staircase effects. In order to alleviate the staircase effects, we propose a new model for restoring blurred images under impulse noise. The model consists of an ℓ1-fidelity term and a TV with overlapping group sparsity (OGS) regularization term. Moreover, we impose a box constraint to the proposed model for getting more accurate solutions. The solving algorithm for our model is under the framework of the alternating direction method of multipliers (ADMM). We use an inner loop which is nested inside the majorization minimization (MM) iteration for the subproblem of the proposed method. Compared with other TV-based methods, numerical results illustrate that the proposed method can significantly improve the restoration quality, both in terms of peak signal-to-noise ratio (PSNR) and relative error (ReE). PMID:25874860
Group field theories for all loop quantum gravity
NASA Astrophysics Data System (ADS)
Oriti, Daniele; Ryan, James P.; Thürigen, Johannes
2015-02-01
Group field theories represent a second quantized reformulation of the loop quantum gravity state space and a completion of the spin foam formalism. States of the canonical theory, in the traditional continuum setting, have support on graphs of arbitrary valence. On the other hand, group field theories have usually been defined in a simplicial context, thus dealing with a restricted set of graphs. In this paper, we generalize the combinatorics of group field theories to cover all the loop quantum gravity state space. As an explicit example, we describe the group field theory formulation of the KKL spin foam model, as well as a particular modified version. We show that the use of tensor model tools allows for the most effective construction. In order to clarify the mathematical basis of our construction and of the formalisms with which we deal, we also give an exhaustive description of the combinatorial structures entering spin foam models and group field theories, both at the level of the boundary states and of the quantum amplitudes.
Method-Unifying View of Loop-Formation Kinetics in Peptide and Protein Folding.
Jacob, Maik H; D'Souza, Roy N; Schwarzlose, Thomas; Wang, Xiaojuan; Huang, Fang; Haas, Elisha; Nau, Werner M
2018-04-26
Protein folding can be described as a probabilistic succession of events in which the peptide chain forms loops closed by specific amino acid residue contacts, herein referred to as loop nodes. To measure loop rates, several photophysical methods have been introduced where a pair of optically active probes is incorporated at selected chain positions and the excited probe undergoes contact quenching (CQ) upon collision with the second probe. The quenching mechanisms involved triplet-triplet energy transfer, photoinduced electron transfer, and collision-induced fluorescence quenching, where the fluorescence of Dbo, an asparagine residue conjugated to 2,3-diazabicyclo[2.2.2]octane, is quenched by tryptophan. The discrepancy between the loop rates afforded from these three CQ techniques has, however, remained unresolved. In analyzing this discrepancy, we now report two short-distance FRET methods where Dbo acts as an energy acceptor in combination with tryptophan and naphtylalanine, two donors with largely different fluorescence lifetimes of 1.3 and 33 ns, respectively. Despite the different quenching mechanisms, the rates from FRET and CQ methods were, surprisingly, of comparable magnitude. This combination of FRET and CQ data led to a unifying physical model and to the conclusion that the rate of loop formation in folding reactions varies not only with the kind and number of residues that constitute the chain but also in particular with the size and properties of the residues that constitute the loop node.
Laser beam pulse formatting method
Daly, Thomas P.; Moses, Edward I.; Patterson, Ralph W.; Sawicki, Richard H.
1994-01-01
A method for formatting a laser beam pulse (20) using one or more delay loops (10). The delay loops (10) have a partially reflective beam splitter (12) and a plurality of highly reflective mirrors (14) arranged such that the laser beam pulse (20) enters into the delay loop (10) through the beam splitter (12) and circulates therein along a delay loop length (24) defined by the mirrors (14). As the laser beam pulse (20) circulates within the delay loop (10) a portion thereof is emitted upon each completed circuit when the laser beam pulse (20) strikes the beam splitter (12). The laser beam pulse (20) is thereby formatted into a plurality of sub-pulses (50, 52, 54 and 56). The delay loops (10) are used in combination to produce complex waveforms by combining the sub-pulses (50, 52, 54 and 56) using additive waveform synthesis.
Synthesis of multi-loop automatic control systems by the nonlinear programming method
NASA Astrophysics Data System (ADS)
Voronin, A. V.; Emelyanova, T. A.
2017-01-01
The article deals with the problem of calculation of the multi-loop control systems optimal tuning parameters by numerical methods and nonlinear programming methods. For this purpose, in the paper the Optimization Toolbox of Matlab is used.
Protein Loop Structure Prediction Using Conformational Space Annealing.
Heo, Seungryong; Lee, Juyong; Joo, Keehyoung; Shin, Hang-Cheol; Lee, Jooyoung
2017-05-22
We have developed a protein loop structure prediction method by combining a new energy function, which we call E PLM (energy for protein loop modeling), with the conformational space annealing (CSA) global optimization algorithm. The energy function includes stereochemistry, dynamic fragment assembly, distance-scaled finite ideal gas reference (DFIRE), and generalized orientation- and distance-dependent terms. For the conformational search of loop structures, we used the CSA algorithm, which has been quite successful in dealing with various hard global optimization problems. We assessed the performance of E PLM with two widely used loop-decoy sets, Jacobson and RAPPER, and compared the results against the DFIRE potential. The accuracy of model selection from a pool of loop decoys as well as de novo loop modeling starting from randomly generated structures was examined separately. For the selection of a nativelike structure from a decoy set, E PLM was more accurate than DFIRE in the case of the Jacobson set and had similar accuracy in the case of the RAPPER set. In terms of sampling more nativelike loop structures, E PLM outperformed E DFIRE for both decoy sets. This new approach equipped with E PLM and CSA can serve as the state-of-the-art de novo loop modeling method.
Chemical Looping Technology: Oxygen Carrier Characteristics.
Luo, Siwei; Zeng, Liang; Fan, Liang-Shih
2015-01-01
Chemical looping processes are characterized as promising carbonaceous fuel conversion technologies with the advantages of manageable CO2 capture and high energy conversion efficiency. Depending on the chemical looping reaction products generated, chemical looping technologies generally can be grouped into two types: chemical looping full oxidation (CLFO) and chemical looping partial oxidation (CLPO). In CLFO, carbonaceous fuels are fully oxidized to CO2 and H2O, as typically represented by chemical looping combustion with electricity as the primary product. In CLPO, however, carbonaceous fuels are partially oxidized, as typically represented by chemical looping gasification with syngas or hydrogen as the primary product. Both CLFO and CLPO share similar operational features; however, the optimum process configurations and the specific oxygen carriers used between them can vary significantly. Progress in both CLFO and CLPO is reviewed and analyzed with specific focus on oxygen carrier developments that characterize these technologies.
Kakaei, Farzad; Beheshtirouy, Samad; Nejatollahi, Seyed Moahammad Reza; Rashidi, Iqbal; Asvadi, Touraj; Habibzadeh, Afshin; Oliaei-Motlagh, Mohammad
2015-12-01
Whipple surgery (pancreaticodeudenectomy) has a high complication rate. We aimed to evaluate whether adding Braun jejunojejunostomy (side-to-side anastomosis of afferent and efferent loops distal to the gastrojejunostomy site) to a standard Whipple procedure would reduce postoperative complications. We conducted a randomized clinical trial comparing patients who underwent standard Whipple surgery (standard group) and patients who underwent standard Whipple surgery with Braun jejunojejunostomy (Braun group). Patients were followed for 1 month after the procedure and postoperative complications were recorded. Our study included 30 patients: 15 in the Braun and 15 in the standard group. In the Braun group, 4 (26.7%) patients experienced 6 complications, whereas in the standard group, 7 (46.7%) patients experienced 11 complications (p = 0.14). Complications in the Braun group were gastrointestinal bleeding and wound infection (n = 1 each) and delayed gastric emptying and pulmonary infection (n = 2 each). Complications in the standard group were death, pancreatic anastomosis leak and biliary anastomosis leak (n = 1 each); gastrointestinal bleeding (n = 2); and afferent loop syndrome and delayed gastric emptying (n = 3 each). There was no significant difference between groups in the subtypes of complications. Our results showed that adding Braun jejunojejunostomy to standard Whipple procedure was associated with lower rates of afferent loop syndrome and delayed gastric emptying. However, more studies are needed to define the role of Braun jejunojejunostomy in this regard. IRCT2014020316473N1 (www.irct.ir).
Crystal defect studies using x-ray diffuse scattering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larson, B.C.
1980-01-01
Microscopic lattice defects such as point (single atom) defects, dislocation loops, and solute precipitates are characterized by local electronic density changes at the defect sites and by distortions of the lattice structure surrounding the defects. The effect of these interruptions of the crystal lattice on the scattering of x-rays is considered in this paper, and examples are presented of the use of the diffuse scattering to study the defects. X-ray studies of self-interstitials in electron irradiated aluminum and copper are discussed in terms of the identification of the interstitial configuration. Methods for detecting the onset of point defect aggregation intomore » dislocation loops are considered and new techniques for the determination of separate size distributions for vacancy loops and interstitial loops are presented. Direct comparisons of dislocation loop measurements by x-rays with existing electron microscopy studies of dislocation loops indicate agreement for larger size loops, but x-ray measurements report higher concentrations in the smaller loop range. Methods for distinguishing between loops and three-dimensional precipitates are discussed and possibilities for detailed studies considered. A comparison of dislocation loop size distributions obtained from integral diffuse scattering measurements with those from TEM show a discrepancy in the smaller sizes similar to that described above.« less
Renewable Energy Generation and Storage Models | Grid Modernization | NREL
-the-loop testing Projects Generator, Plant, and Storage Modeling, Simulation, and Validation NREL power plants. Power Hardware-in-the-Loop Testing NREL researchers are developing software-and-hardware -combined simulation testing methods known as power hardware-in-the-loop testing. Power hardware in the loop
Olson, Mark A; Feig, Michael; Brooks, Charles L
2008-04-15
This article examines ab initio methods for the prediction of protein loops by a computational strategy of multiscale conformational sampling and physical energy scoring functions. Our approach consists of initial sampling of loop conformations from lattice-based low-resolution models followed by refinement using all-atom simulations. To allow enhanced conformational sampling, the replica exchange method was implemented. Physical energy functions based on CHARMM19 and CHARMM22 parameterizations with generalized Born (GB) solvent models were applied in scoring loop conformations extracted from the lattice simulations and, in the case of all-atom simulations, the ensemble of conformations were generated and scored with these models. Predictions are reported for 25 loop segments, each eight residues long and taken from a diverse set of 22 protein structures. We find that the simulations generally sampled conformations with low global root-mean-square-deviation (RMSD) for loop backbone coordinates from the known structures, whereas clustering conformations in RMSD space and scoring detected less favorable loop structures. Specifically, the lattice simulations sampled basins that exhibited an average global RMSD of 2.21 +/- 1.42 A, whereas clustering and scoring the loop conformations determined an RMSD of 3.72 +/- 1.91 A. Using CHARMM19/GB to refine the lattice conformations improved the sampling RMSD to 1.57 +/- 0.98 A and detection to 2.58 +/- 1.48 A. We found that further improvement could be gained from extending the upper temperature in the all-atom refinement from 400 to 800 K, where the results typically yield a reduction of approximately 1 A or greater in the RMSD of the detected loop. Overall, CHARMM19 with a simple pairwise GB solvent model is more efficient at sampling low-RMSD loop basins than CHARMM22 with a higher-resolution modified analytical GB model; however, the latter simulation method provides a more accurate description of the all-atom energy surface, yet demands a much greater computational cost. (c) 2007 Wiley Periodicals, Inc.
Improving predicted protein loop structure ranking using a Pareto-optimality consensus method.
Li, Yaohang; Rata, Ionel; Chiu, See-wing; Jakobsson, Eric
2010-07-20
Accurate protein loop structure models are important to understand functions of many proteins. Identifying the native or near-native models by distinguishing them from the misfolded ones is a critical step in protein loop structure prediction. We have developed a Pareto Optimal Consensus (POC) method, which is a consensus model ranking approach to integrate multiple knowledge- or physics-based scoring functions. The procedure of identifying the models of best quality in a model set includes: 1) identifying the models at the Pareto optimal front with respect to a set of scoring functions, and 2) ranking them based on the fuzzy dominance relationship to the rest of the models. We apply the POC method to a large number of decoy sets for loops of 4- to 12-residue in length using a functional space composed of several carefully-selected scoring functions: Rosetta, DOPE, DDFIRE, OPLS-AA, and a triplet backbone dihedral potential developed in our lab. Our computational results show that the sets of Pareto-optimal decoys, which are typically composed of approximately 20% or less of the overall decoys in a set, have a good coverage of the best or near-best decoys in more than 99% of the loop targets. Compared to the individual scoring function yielding best selection accuracy in the decoy sets, the POC method yields 23%, 37%, and 64% less false positives in distinguishing the native conformation, indentifying a near-native model (RMSD < 0.5A from the native) as top-ranked, and selecting at least one near-native model in the top-5-ranked models, respectively. Similar effectiveness of the POC method is also found in the decoy sets from membrane protein loops. Furthermore, the POC method outperforms the other popularly-used consensus strategies in model ranking, such as rank-by-number, rank-by-rank, rank-by-vote, and regression-based methods. By integrating multiple knowledge- and physics-based scoring functions based on Pareto optimality and fuzzy dominance, the POC method is effective in distinguishing the best loop models from the other ones within a loop model set.
Improving predicted protein loop structure ranking using a Pareto-optimality consensus method
2010-01-01
Background Accurate protein loop structure models are important to understand functions of many proteins. Identifying the native or near-native models by distinguishing them from the misfolded ones is a critical step in protein loop structure prediction. Results We have developed a Pareto Optimal Consensus (POC) method, which is a consensus model ranking approach to integrate multiple knowledge- or physics-based scoring functions. The procedure of identifying the models of best quality in a model set includes: 1) identifying the models at the Pareto optimal front with respect to a set of scoring functions, and 2) ranking them based on the fuzzy dominance relationship to the rest of the models. We apply the POC method to a large number of decoy sets for loops of 4- to 12-residue in length using a functional space composed of several carefully-selected scoring functions: Rosetta, DOPE, DDFIRE, OPLS-AA, and a triplet backbone dihedral potential developed in our lab. Our computational results show that the sets of Pareto-optimal decoys, which are typically composed of ~20% or less of the overall decoys in a set, have a good coverage of the best or near-best decoys in more than 99% of the loop targets. Compared to the individual scoring function yielding best selection accuracy in the decoy sets, the POC method yields 23%, 37%, and 64% less false positives in distinguishing the native conformation, indentifying a near-native model (RMSD < 0.5A from the native) as top-ranked, and selecting at least one near-native model in the top-5-ranked models, respectively. Similar effectiveness of the POC method is also found in the decoy sets from membrane protein loops. Furthermore, the POC method outperforms the other popularly-used consensus strategies in model ranking, such as rank-by-number, rank-by-rank, rank-by-vote, and regression-based methods. Conclusions By integrating multiple knowledge- and physics-based scoring functions based on Pareto optimality and fuzzy dominance, the POC method is effective in distinguishing the best loop models from the other ones within a loop model set. PMID:20642859
Digital Phase-Locked Loop With Phase And Frequency Feedback
NASA Technical Reports Server (NTRS)
Thomas, J. Brooks
1991-01-01
Advanced design for digital phase-lock loop (DPLL) allows loop gains higher than those used in other designs. Divided into two major components: counterrotation processor and tracking processor. Notable features include use of both phase and rate-of-change-of-phase feedback instead of frequency feedback alone, normalized sine phase extractor, improved method for extracting measured phase, and improved method for "compressing" output rate.
Pedowitz, Robert A; Nicandri, Gregg T; Angelo, Richard L; Ryu, Richard K N; Gallagher, Anthony G
2015-10-01
To assess a new method for biomechanical assessment of arthroscopic knots and to establish proficiency benchmarks using the Fundamentals of Arthroscopic Surgery Training (FAST) Program workstation and knot tester. The first study group included 20 faculty at an Arthroscopy Association of North America resident arthroscopy course (19.9 ± 8.25 years in practice). The second group comprised 30 experienced surgeons attending an Arthroscopy Association of North America fall course (17.1 ± 19.3 years in practice). The training group included 44 postgraduate year 4 or 5 orthopaedic residents in a randomized, prospective study of proficiency-based training, with 3 subgroups: group A, standard training (n = 14); group B, workstation practice (n = 14); and group C, proficiency-based progression using the knot tester (n = 16). Each subject tied 5 arthroscopic knots backed up by 3 reversed hitches on alternating posts. Knots were tied under video control around a metal mandrel through a cannula within an opaque dome (FAST workstation). Each suture loop was stressed statically at 15 lb for 15 seconds. A calibrated sizer measured loop expansion. Knot failure was defined as 3 mm of loop expansion or greater. In the faculty group, 24% of knots "failed" under load. Performance was inconsistent: 12 faculty had all knots pass, whereas 2 had all knots fail. In the second group of practicing surgeons, 21% of the knots failed under load. Overall, 56 of 250 knots (22%) tied by experienced surgeons failed. For the postgraduate year 4 or 5 residents, the aggregate knot failure rate was 26% for the 220 knots tied. Group C residents had an 11% knot failure rate (half the overall faculty rate, P = .013). The FAST workstation and knot tester offer a simple and reproducible educational approach for enhancement of arthroscopic knot-tying skills. Our data suggest that there is significant room for improvement in the quality and consistency of these important arthroscopic skills, even for experienced arthroscopic surgeons. Level II, prospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Comparison of Five System Identification Algorithms for Rotorcraft Higher Harmonic Control
NASA Technical Reports Server (NTRS)
Jacklin, Stephen A.
1998-01-01
This report presents an analysis and performance comparison of five system identification algorithms. The methods are presented in the context of identifying a frequency-domain transfer matrix for the higher harmonic control (HHC) of helicopter vibration. The five system identification algorithms include three previously proposed methods: (1) the weighted-least- squares-error approach (in moving-block format), (2) the Kalman filter method, and (3) the least-mean-squares (LMS) filter method. In addition there are two new ones: (4) a generalized Kalman filter method and (5) a generalized LMS filter method. The generalized Kalman filter method and the generalized LMS filter method were derived as extensions of the classic methods to permit identification by using more than one measurement per identification cycle. Simulation results are presented for conditions ranging from the ideal case of a stationary transfer matrix and no measurement noise to the more complex cases involving both measurement noise and transfer-matrix variation. Both open-loop identification and closed- loop identification were simulated. Closed-loop mode identification was more challenging than open-loop identification because of the decreasing signal-to-noise ratio as the vibration became reduced. The closed-loop simulation considered both local-model identification, with measured vibration feedback and global-model identification with feedback of the identified uncontrolled vibration. The algorithms were evaluated in terms of their accuracy, stability, convergence properties, computation speeds, and relative ease of implementation.
Effects of various freezing containers for vitrification freezing on mouse oogenesis.
Kim, Ji Chul; Kim, Jae Myeoung; Seo, Byoung Boo
2016-01-01
In the present study, various freezing containers were tested for mouse embryos of respective developmental stages; embryos were vitrified and then their survival rate and developmental rate were monitored. Mouse two cell, 8 cell, and blastula stage embryos underwent vitrification freezing-thawing and then their recovery rate, survival rate, development rate, and hatching rate were investigated. EM-grid, OPS, and cryo-loop were utilized for vitrification freezing-thawing of mouse embryos. It was found that recovery rate and survival rate were higher in the group of cryo-loop compared to those of EM-grid (p < 0.05). Embryonic development rate, two cell embryos to blastocyst, as well as hatching rate were higher in the control group compared to the EM-grid group and OPS group (p < 0.05), yet no difference was noted between the control group and cryo-loop group. Development rate and hatching rate of eight cell morulae and blastocysts were all lower in the treatment groups than the control group whilst hatching rate of blastocysts was higher in the control group compared to the groups of EM-grid and OPS (p < 0.05); although the cryo-loop group was shown to be slightly higher than other groups, it was not statistically significant. In the study, we investigate effects of freezing containers on vitrified embryos of respective developmental stages; it was demonstrated that higher developmental rate was shown in more progressed (or developed) embryos with more blastomeres. There was however, no difference in embryonic development rate was shown amongst containers. Taken together, further additional studies are warranted with regards to 1) manipulation techniques of embryos for various vitrification freezing containers and 2) preventive measures against contamination via liquid nitrogen.
Skin bridge versus rod colostomy in children - comparison between complications.
Askarpour, Shahnam; Peyvasteh, Mehran; Changai, Bahram; Javaherizadeh, Hazhir
2012-10-01
Due to economic problems, sigmoid loop colostomy using glass rod may cause problems for our patients for finding glass rod and several visits. The aim of the study was to compare rod versus skin bridge colostomy. In this study, 42 cases who are candidate for colostomy were included. Cases were randomly placed in skin bridge and rod colostomy group. Independent sample t-test and Chi-square were used for comparison. SPSS version 16.0 (SPSS Inc, Chicago, IL, USA) was used for analysis. Of 42 cases, 20 were male and 22 were female. Hirschsprung's disease was the indication of colostomy in 33 cases. In nine cases, imperforate anus was the indication of colostomy. Mean time of surgery was 79.4 and 82.5 minute for the rod and skin bridge group respectively (P>0.05). Retraction was seen in 2 case of rod group, and no case of skin bridge group. Prolapse was seen in 2 (9.5%) case of rod group and 1(4.7%) case in skin bridge. There were no reports of necrosis, stenosis, and hernia in both groups. In the skin bridge group the rates of complications were lower but the groups are too small for statistical analysis. Colostomy with a skin bridge method may decrease number of revision and expenses and may be appropriate option. Sigmoid loop colostomy using skin bridge flap may be appropriate choice in developing country. Another study with more samples is recommended to better comparison of Skin Bridge versus rod colostomy.
Bao, Yu; Hayashida, Morihiro; Akutsu, Tatsuya
2016-11-25
Dicer is necessary for the process of mature microRNA (miRNA) formation because the Dicer enzyme cleaves pre-miRNA correctly to generate miRNA with correct seed regions. Nonetheless, the mechanism underlying the selection of a Dicer cleavage site is still not fully understood. To date, several studies have been conducted to solve this problem, for example, a recent discovery indicates that the loop/bulge structure plays a central role in the selection of Dicer cleavage sites. In accordance with this breakthrough, a support vector machine (SVM)-based method called PHDCleav was developed to predict Dicer cleavage sites which outperforms other methods based on random forest and naive Bayes. PHDCleav, however, tests only whether a position in the shift window belongs to a loop/bulge structure. In this paper, we used the length of loop/bulge structures (in addition to their presence or absence) to develop an improved method, LBSizeCleav, for predicting Dicer cleavage sites. To evaluate our method, we used 810 empirically validated sequences of human pre-miRNAs and performed fivefold cross-validation. In both 5p and 3p arms of pre-miRNAs, LBSizeCleav showed greater prediction accuracy than PHDCleav did. This result suggests that the length of loop/bulge structures is useful for prediction of Dicer cleavage sites. We developed a novel algorithm for feature space mapping based on the length of a loop/bulge for predicting Dicer cleavage sites. The better performance of our method indicates the usefulness of the length of loop/bulge structures for such predictions.
Limit Cycle Bifurcations by Perturbing a Piecewise Hamiltonian System with a Double Homoclinic Loop
NASA Astrophysics Data System (ADS)
Xiong, Yanqin
2016-06-01
This paper is concerned with the bifurcation problem of limit cycles by perturbing a piecewise Hamiltonian system with a double homoclinic loop. First, the derivative of the first Melnikov function is provided. Then, we use it, together with the analytic method, to derive the asymptotic expansion of the first Melnikov function near the loop. Meanwhile, we present the first coefficients in the expansion, which can be applied to study the limit cycle bifurcation near the loop. We give sufficient conditions for this system to have 14 limit cycles in the neighborhood of the loop. As an application, a piecewise polynomial Liénard system is investigated, finding six limit cycles with the help of the obtained method.
Evidence for Nonuniform Heating of Coronal Loops Inferred from Multithread Modeling of TRACE Data
NASA Astrophysics Data System (ADS)
Aschwanden, Markus J.; Nightingale, Richard W.; Alexander, David
2000-10-01
The temperature Te(s) and density structure ne(s) of active region loops in EUV observed with TRACE is modeled with a multithread model, synthesized from the summed emission of many loop threads that have a distribution of maximum temperatures and that satisfy the steady state Rosner-Tucker-Vaiana (RTV) scaling law, modified by Serio et al. for gravitational stratification (called RTVSp in the following). In a recent Letter, Reale & Peres demonstrated that this method can explain the almost isothermal appearance of TRACE loops (observed by Lenz et al.) as derived from the filter-ratio method. From model-fitting of the 171 and 195 Å fluxes of 41 loops, which have loop half-lengths in the range of L=4-320 Mm, we find that (1) the EUV loops consist of near-isothermal loop threads with substantially smaller temperature gradients than are predicted by the RTVSp model; (2) the loop base pressure, p0~0.3+/-0.1 dynes cm-2, is independent of the loop length L, and it agrees with the RTVSp model for the shortest loops but exceeds the RTVSp model up to a factor of 35 for the largest loops; and (3) the pressure scale height is consistent with hydrostatic equilibrium for the shortest loops but exceeds the temperature scale height up to a factor of ~3 for the largest loops. The data indicate that cool EUV loops in the temperature range of Te~0.8-1.6 MK cannot be explained with the static steady state RTVSp model in terms of uniform heating but are fully consistent with Serio's model in the case of nonuniform heating (RTVSph), with heating scale heights in the range of sH=17+/-6 Mm. This heating function provides almost uniform heating for small loops (L<~20 Mm), but restricts heating to the footpoints of large loops (L~50-300 Mm).
Cosmic strings and the microwave sky. I - Anisotropy from moving strings
NASA Technical Reports Server (NTRS)
Stebbins, Albert
1988-01-01
A method is developed for calculating the component of the microwave anisotropy around cosmic string loops due to their rapidly changing gravitational fields. The method is only valid for impact parameters from the string much smaller than the horizon size at the time the photon passes the string. The method makes it possible to calculate the temperature pattern around arbitrary string configurations numerically in terms of one-dimensional integrals. This method is applied to temperature jump across a string, confirming and extending previous work. It is also applied to cusps and kinks on strings, and to determining the temperature pattern far from a strong loop. The temperature pattern around a few loop configurations is explicitly calculated. Comparisons with the work of Brandenberger et al. (1986) indicates that they have overestimated the MBR anisotropy from gravitational radiation emitted from loops.
A novel Cs-(129)Xe atomic spin gyroscope with closed-loop Faraday modulation.
Fang, Jiancheng; Wan, Shuangai; Qin, Jie; Zhang, Chen; Quan, Wei; Yuan, Heng; Dong, Haifeng
2013-08-01
We report a novel Cs-(129)Xe atomic spin gyroscope (ASG) with closed-loop Faraday modulation method. This ASG requires approximately 30 min to start-up and 110 °C to operate. A closed-loop Faraday modulation method for measurement of the optical rotation was used in this ASG. This method uses an additional Faraday modulator to suppress the laser intensity fluctuation and Faraday modulator thermal induced fluctuation. We theoretically and experimentally validate this method in the Cs-(129)Xe ASG and achieved a bias stability of approximately 3.25 °∕h.
Healthy Kids, Healthy Cuba: findings from a group model building process in the rural Southwest.
Keane, Patricia; Ortega, Alejandro; Linville, Jeanette
2015-01-01
Healthy Kids, Healthy Cuba (HKHCuba) is 1 of 49 community partnerships that participated in the national Healthy Kids, Healthy Communities program of the Robert Wood Johnson Foundation. One method of evaluation was to introduce systems thinking at the community level by identifying the essential parts of the HKHCuba system and how it influences policy and environmental changes to promote healthy eating and active living as well as to prevent childhood obesity in this unique, triethnic, rural community in New Mexico. In this cross-sectional design, 12 HKHCuba partners participated in a group model building (GMB) session to develop behavior over time graphs and a causal loop diagram. Twenty-seven influences identified in the behavior over time graphs emerged as feedback loops and 5 subsystems emerged within the causal loop diagram. In addition to specific strategy-related influences (eg, access to healthy food, participation in community gardens), sense of cultural pride, sense of community, and social engagement, particularly among youth, were highly salient topics. The GMB process provided participants with the opportunity to explore the connections across their specific areas of work and make connections between policy and environmental influences on healthy eating and active living behaviors. The GMB processes and systems thinking approaches were new to the majority of participants, received positively, and perhaps should have been introduced earlier in the project period.
Ianchulev, Tsontcho; Chang, David F; Koo, Edward; MacDonald, Susan; Calvo, Ernesto; Tyson, Farrell Toby; Vasquez, Andrea; Ahmed, Iqbal Ike K
2018-04-18
To assess the safety and efficacy of microinterventional endocapsular nuclear fragmentation in moderate to severe cataracts. This was a prospective single-masked multisurgeon interventional randomised controlled trial (ClinicalTrials.gov NCT02843594) where 101 eyes of 101 subjects with grade 3-4+ nuclear cataracts were randomised to torsional phacoemulsification alone (controls) or torsional phacoemulsification with adjunctive endocapsular nuclear fragmentation using a manual microinterventional nitinol filament loop device (miLOOP group). Outcome measures were phacoemulsification efficiency as measured by ultrasound energy (cumulative dispersed energy (CDE) units) and fluidics requirements (total irrigation fluid used) as well as incidence of intraoperative and postoperative complications. Only high-grade advanced cataracts were enrolled with more than 85% of eyes with baseline best corrected visual acuity (BCVA) of 20/200 or worse in either group. Mean CDE was 53% higher in controls (32.8±24.9 vs 21.4±13.1 with miLOOP assistance) (p=0.004). Endothelial cell loss after surgery was low and similar between groups (7-8%, p=0.561) One-month BCVA averaged 20/27 Snellen in miLOOP eyes and 20/24 in controls. No direct complications were caused by the miLOOP. In two cases, capsular tears occurred during IOL implantation and in all remaining cases during phacoemulsification, with none occurring during the miLOOP nucleus disassembly part of the procedure. Microinterventional endocapsular fragmentation with the manual, disposable miLOOP device achieved consistent, ultrasound-free, full-thickness nucleus disassembly and significantly improved overall phaco efficiency in advanced cataracts. NCT02843594. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Sphinx: merging knowledge-based and ab initio approaches to improve protein loop prediction
Marks, Claire; Nowak, Jaroslaw; Klostermann, Stefan; Georges, Guy; Dunbar, James; Shi, Jiye; Kelm, Sebastian
2017-01-01
Abstract Motivation: Loops are often vital for protein function, however, their irregular structures make them difficult to model accurately. Current loop modelling algorithms can mostly be divided into two categories: knowledge-based, where databases of fragments are searched to find suitable conformations and ab initio, where conformations are generated computationally. Existing knowledge-based methods only use fragments that are the same length as the target, even though loops of slightly different lengths may adopt similar conformations. Here, we present a novel method, Sphinx, which combines ab initio techniques with the potential extra structural information contained within loops of a different length to improve structure prediction. Results: We show that Sphinx is able to generate high-accuracy predictions and decoy sets enriched with near-native loop conformations, performing better than the ab initio algorithm on which it is based. In addition, it is able to provide predictions for every target, unlike some knowledge-based methods. Sphinx can be used successfully for the difficult problem of antibody H3 prediction, outperforming RosettaAntibody, one of the leading H3-specific ab initio methods, both in accuracy and speed. Availability and Implementation: Sphinx is available at http://opig.stats.ox.ac.uk/webapps/sphinx. Contact: deane@stats.ox.ac.uk Supplementary information: Supplementary data are available at Bioinformatics online. PMID:28453681
Sphinx: merging knowledge-based and ab initio approaches to improve protein loop prediction.
Marks, Claire; Nowak, Jaroslaw; Klostermann, Stefan; Georges, Guy; Dunbar, James; Shi, Jiye; Kelm, Sebastian; Deane, Charlotte M
2017-05-01
Loops are often vital for protein function, however, their irregular structures make them difficult to model accurately. Current loop modelling algorithms can mostly be divided into two categories: knowledge-based, where databases of fragments are searched to find suitable conformations and ab initio, where conformations are generated computationally. Existing knowledge-based methods only use fragments that are the same length as the target, even though loops of slightly different lengths may adopt similar conformations. Here, we present a novel method, Sphinx, which combines ab initio techniques with the potential extra structural information contained within loops of a different length to improve structure prediction. We show that Sphinx is able to generate high-accuracy predictions and decoy sets enriched with near-native loop conformations, performing better than the ab initio algorithm on which it is based. In addition, it is able to provide predictions for every target, unlike some knowledge-based methods. Sphinx can be used successfully for the difficult problem of antibody H3 prediction, outperforming RosettaAntibody, one of the leading H3-specific ab initio methods, both in accuracy and speed. Sphinx is available at http://opig.stats.ox.ac.uk/webapps/sphinx. deane@stats.ox.ac.uk. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press.
Automatic Event Detection in Search for Inter-Moss Loops in IRIS Si IV Slit-Jaw Images
NASA Technical Reports Server (NTRS)
Fayock, Brian; Winebarger, Amy R.; De Pontieu, Bart
2015-01-01
The high-resolution capabilities of the Interface Region Imaging Spectrometer (IRIS) mission have allowed the exploration of the finer details of the solar magnetic structure from the chromosphere to the lower corona that have previously been unresolved. Of particular interest to us are the relatively short-lived, low-lying magnetic loops that have foot points in neighboring moss regions. These inter-moss loops have also appeared in several AIA pass bands, which are generally associated with temperatures that are at least an order of magnitude higher than that of the Si IV emission seen in the 1400 angstrom pass band of IRIS. While the emission lines seen in these pass bands can be associated with a range of temperatures, the simultaneous appearance of these loops in IRIS 1400 and AIA 171, 193, and 211 suggest that they are not in ionization equilibrium. To study these structures in detail, we have developed a series of algorithms to automatically detect signal brightening or events on a pixel-by-pixel basis and group them together as structures for each of the above data sets. These algorithms have successfully picked out all activity fitting certain adjustable criteria. The resulting groups of events are then statistically analyzed to determine which characteristics can be used to distinguish the inter-moss loops from all other structures. While a few characteristic histograms reveal that manually selected inter-moss loops lie outside the norm, a combination of several characteristics will need to be used to determine the statistical likelihood that a group of events be categorized automatically as a loop of interest. The goal of this project is to be able to automatically pick out inter-moss loops from an entire data set and calculate the characteristics that have previously been determined manually, such as length, intensity, and lifetime. We will discuss the algorithms, preliminary results, and current progress of automatic characterization.
Rysavy, Steven J; Beck, David A C; Daggett, Valerie
2014-11-01
Protein function is intimately linked to protein structure and dynamics yet experimentally determined structures frequently omit regions within a protein due to indeterminate data, which is often due protein dynamics. We propose that atomistic molecular dynamics simulations provide a diverse sampling of biologically relevant structures for these missing segments (and beyond) to improve structural modeling and structure prediction. Here we make use of the Dynameomics data warehouse, which contains simulations of representatives of essentially all known protein folds. We developed novel computational methods to efficiently identify, rank and retrieve small peptide structures, or fragments, from this database. We also created a novel data model to analyze and compare large repositories of structural data, such as contained within the Protein Data Bank and the Dynameomics data warehouse. Our evaluation compares these structural repositories for improving loop predictions and analyzes the utility of our methods and models. Using a standard set of loop structures, containing 510 loops, 30 for each loop length from 4 to 20 residues, we find that the inclusion of Dynameomics structures in fragment-based methods improves the quality of the loop predictions without being dependent on sequence homology. Depending on loop length, ∼ 25-75% of the best predictions came from the Dynameomics set, resulting in lower main chain root-mean-square deviations for all fragment lengths using the combined fragment library. We also provide specific cases where Dynameomics fragments provide better predictions for NMR loop structures than fragments from crystal structures. Online access to these fragment libraries is available at http://www.dynameomics.org/fragments. © 2014 The Protein Society.
Rysavy, Steven J; Beck, David AC; Daggett, Valerie
2014-01-01
Protein function is intimately linked to protein structure and dynamics yet experimentally determined structures frequently omit regions within a protein due to indeterminate data, which is often due protein dynamics. We propose that atomistic molecular dynamics simulations provide a diverse sampling of biologically relevant structures for these missing segments (and beyond) to improve structural modeling and structure prediction. Here we make use of the Dynameomics data warehouse, which contains simulations of representatives of essentially all known protein folds. We developed novel computational methods to efficiently identify, rank and retrieve small peptide structures, or fragments, from this database. We also created a novel data model to analyze and compare large repositories of structural data, such as contained within the Protein Data Bank and the Dynameomics data warehouse. Our evaluation compares these structural repositories for improving loop predictions and analyzes the utility of our methods and models. Using a standard set of loop structures, containing 510 loops, 30 for each loop length from 4 to 20 residues, we find that the inclusion of Dynameomics structures in fragment-based methods improves the quality of the loop predictions without being dependent on sequence homology. Depending on loop length, ∼25–75% of the best predictions came from the Dynameomics set, resulting in lower main chain root-mean-square deviations for all fragment lengths using the combined fragment library. We also provide specific cases where Dynameomics fragments provide better predictions for NMR loop structures than fragments from crystal structures. Online access to these fragment libraries is available at http://www.dynameomics.org/fragments. PMID:25142412
Arnautova, Yelena A; Abagyan, Ruben A; Totrov, Maxim
2011-02-01
We report the development of internal coordinate mechanics force field (ICMFF), new force field parameterized using a combination of experimental data for crystals of small molecules and quantum mechanics calculations. The main features of ICMFF include: (a) parameterization for the dielectric constant relevant to the condensed state (ε = 2) instead of vacuum, (b) an improved description of hydrogen-bond interactions using duplicate sets of van der Waals parameters for heavy atom-hydrogen interactions, and (c) improved backbone covalent geometry and energetics achieved using novel backbone torsional potentials and inclusion of the bond angles at the C(α) atoms into the internal variable set. The performance of ICMFF was evaluated through loop modeling simulations for 4-13 residue loops. ICMFF was combined with a solvent-accessible surface area solvation model optimized using a large set of loop decoys. Conformational sampling was carried out using the biased probability Monte Carlo method. Average/median backbone root-mean-square deviations of the lowest energy conformations from the native structures were 0.25/0.21 Å for four residues loops, 0.84/0.46 Å for eight residue loops, and 1.16/0.73 Å for 12 residue loops. To our knowledge, these results are significantly better than or comparable with those reported to date for any loop modeling method that does not take crystal packing into account. Moreover, the accuracy of our method is on par with the best previously reported results obtained considering the crystal environment. We attribute this success to the high accuracy of the new ICM force field achieved by meticulous parameterization, to the optimized solvent model, and the efficiency of the search method. © 2010 Wiley-Liss, Inc.
Antisymmetric Wilson loops in N = 4 SYM beyond the planar limit
NASA Astrophysics Data System (ADS)
Gordon, James
2018-01-01
We study the 1/2 -BPS circular Wilson loop in the totally antisymmetric representation of the gauge group in N = 4 supersymmetric Yang-Mills. This observable is captured by a Gaussian matrix model with appropriate insertion. We compute the first 1 /N correction at leading order in 't Hooft coupling by means of the matrix model loop equations. Disagreement with the 1-loop effective action of the holographically dual D5-brane suggests the need to account for gravitational backreaction on the string theory side.
An Assessment of Correlation between Dermatoglyphic Patterns and Sagittal Skeletal Discrepancies
Philip, Biju; Madathody, Deepika; Mathew, Manu; Paul, Jose; Dlima, Johnson Prakash
2017-01-01
Introduction Investigators over years have been fascinated by dermatoglyphic patterns which has led to the development of dermatoglyphics as a science with numerous applications in various fields other than being the best and most widely used method for personal identification. Aim To assess the correlation between dermatoglyphic patterns and sagittal skeletal discrepancies. Materials and Methods A total of 180 patients, aged 18-40 years, were selected from those who attended the outpatient clinic of the Deparment of Orthodontics and Dentofacial Orthopedics, Mar Baselios Dental College, Kothamangalam, Kerala, India. The fingerprints of both hands were taken by ink and stamp method after proper hand washing. The patterns of arches, loops and whorls in fingerprints were assessed. The total ridge count was also evaluated. Data was also sent to the fingerprint experts for expert evaluation. The sagittal jaw relation was determined from the patient’s lateral cephalogram. The collected data was then statistically analyzed using Chi-square tests, ANOVA and Post-hoc tests and a Multinomial regression prediction was also done. Results A significant association was observed between the dermatoglyphic pattern exhibited by eight fingers and the sagittal skeletal discrepancies (p<0.05). An increased distribution of whorl pattern was observed in the skeletal Class II with maxillary excess group and skeletal Class II with mandibular deficiency group while an increased distribution of loop pattern was seen in the skeletal Class III with mandibular excess group and skeletal Class III with maxillary deficiency group. Higher mean of total ridge count was also seen in the groups of skeletal Class II with maxillary excess and skeletal Class II with mandibular deficiency. Multinomial regression predicting skeletal pattern with respect to the fingerprint pattern showed that the left thumb impression fits the best model for predicting the skeletal pattern. Conclusion There was a significant association between dermatoglyphic patterns and sagittal skeletal discrepancies. Dermatoglyphics could serve as a cost effective screening tool of these craniofacial problems. PMID:28511506
Belcaro, G; Cesarone, M R; Ledda, A; Cornelli, U; Dugall, M; Di Renzo, A; Hosoi, M; Stuard, S; Vinciguerra, G; Pellegrini, L; Gizzi, G
2008-10-01
Fingerprints (FP), characteristic of humans, are impressions due to skin marks (ridges) on fingertips. Ridges are present on fingers/hands forming curved lines of different sizes/patterns. The point where a line stops or splits is defined typica' (their number/amount constitute identification patterns). FP are permanent and unique. This study compared FP patterns with cardiovascular risk factors: 7 main types of FP were used: 1. Arch: lines form waves from one site to the other side. 2. Tentarch: like arches but with a rising stick in the middle. 3. Loop: lines coming from one site returning in the middle to the same site. 4. Double loop: like loops but with two loops inside: one standing, one hanging. 5. Pocked loop: like the loop but with a small circle in the turning point. 6. Whorl: lines make circles. 7. Mixed figure: composed of different figures. There are two kinds of real typica: A. Ending line; B. Splitting lines (bifurcations). Several combinations may result. Ultrasound evaluation of carotid/femoral arteries in asymptomatic subjects. Arteries were evaluated with high-resolution ultrasound at the bifurcations. Four classes were defined: 1: normal intima-media (IMT) complex; 2: IMT thickening; 3: non-stenosing plaques (<50% stenosis); 4: stenosing plaque (>50%). Subjects in classes 1, 2, 3 were included into the analysis made comparing FP patterns and ultrasound. For each FP pattern: A. the main proportion of subjects with cardiovacular risk factors (91%) had arches (41.2%) and loops (either single, 38.2% or double 11.7% for a total of 49.9%). B. The remaining classes were statistically less important. C. The number of ridges per square mm was comparable in all pattern classes. D. The analysis of typica and other ridges characteristics requires a more elaborated system. Future research must define simple, low cost screening methods for preselection of subjects at higher cardiovascular risk or for exclusion of low risk subjects. The evaluation of fingerprint pattern may be useful to define risk groups.
Three-Dimensional Printing of Vitrification Loop Prototypes for Aquatic Species.
Tiersch, Nolan J; Childress, William M; Tiersch, Terrence R
2018-05-16
Vitrification is a method of cryopreservation that freezes samples rapidly, while forming an amorphous solid ("glass"), typically in small (μL) volumes. The goal of this project was to create, by three-dimensional (3D) printing, open vitrification devices based on an elliptical loop that could be efficiently used and stored. Vitrification efforts can benefit from the application of 3D printing, and to begin integration of this technology, we addressed four main variables: thermoplastic filament type, loop length, loop height, and method of loading. Our objectives were to: (1) design vitrification loops with varied dimensions; (2) print prototype loops for testing; (3) evaluate loading methods for the devices; and (4) classify vitrification responses to multiple device configurations. The various configurations were designed digitally using 3D CAD (Computer Aided Design) software, and prototype devices were produced with MakerBot ® 3D printers. The thermoplastic filaments used to produce devices were acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA). Vitrification devices were characterized by the film volumes formed with different methods of loading (pipetting or submersion). Frozen films were classified to determine vitrification quality: zero (opaque, or abundant crystalline ice formation); one (translucent, or partial vitrification), or two (transparent, or substantial vitrification, glass). A published vitrification solution was used to conduct experiments. Loading by pipetting formed frozen films more reliably than by submersion, but submersion yielded fewer filling problems and was more rapid. The loop designs that yielded the highest levels of vitrification enabled rapid transfer of heat, and most often were characterized as being longer and consisting of fewer layers (height). 3D printing can assist standardization of vitrification methods and research, yet can also provide the ability to quickly design and fabricate custom devices when needed.
Steady-state phase error for a phase-locked loop subjected to periodic Doppler inputs
NASA Technical Reports Server (NTRS)
Chen, C.-C.; Win, M. Z.
1991-01-01
The performance of a carrier phase locked loop (PLL) driven by a periodic Doppler input is studied. By expanding the Doppler input into a Fourier series and applying the linearized PLL approximations, it is easy to show that, for periodic frequency disturbances, the resulting steady state phase error is also periodic. Compared to the method of expanding frequency excursion into a power series, the Fourier expansion method can be used to predict the maximum phase error excursion for a periodic Doppler input. For systems with a large Doppler rate fluctuation, such as an optical transponder aboard an Earth orbiting spacecraft, the method can be applied to test whether a lower order tracking loop can provide satisfactory tracking and thereby save the effect of a higher order loop design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kato, Masato; Wynn, R. Max; Chuang, Jacinta L.
2009-09-11
We report the crystal structures of the phosporylated pyruvate dehydrogenase (E1p) component of the human pyruvate dehydrogenase complex (PDC). The complete phosphorylation at Ser264-{alpha} (site 1) of a variant E1p protein was achieved using robust pyruvate dehydrogenase kinase 4 free of the PDC core. We show that unlike its unmodified counterpart, the presence of a phosphoryl group at Ser264-{alpha} prevents the cofactor thiamine diphosphate-induced ordering of the two loops carrying the three phosphorylation sites. The disordering of these phosphorylation loops is caused by a previously unrecognized steric clash between the phosphoryl group at site 1 and a nearby Ser266-{alpha}, whichmore » nullifies a hydrogen-bonding network essential for maintaining the loop conformations. The disordered phosphorylation loops impede the binding of lipoyl domains of the PDC core to E1p, negating the reductive acetylation step. This results in the disruption of the substrate channeling in the PDC, leading to the inactivation of this catalytic machine.« less
Man-in-the-control-loop simulation of manipulators
NASA Technical Reports Server (NTRS)
Chang, J. L.; Lin, Tsung-Chieh; Yae, K. Harold
1989-01-01
A method to achieve man-in-the-control-loop simulation is presented. Emerging real-time dynamics simulation suggests a potential for creating an interactive design workstation with a human operator in the control loop. The recursive formulation for multibody dynamics simulation is studied to determine requirements for man-in-the-control-loop simulation. High speed computer graphics techniques provides realistic visual cues for the simulator. Backhoe and robot arm simulations are implemented to demonstrate the capability of man-in-the-control-loop simulation.
Super energy saver heat pump with dynamic hybrid phase change material
Ally, Moonis Raza [Oak Ridge, TN; Tomlinson, John Jager [Knoxville, TN; Rice, Clifford Keith [Clinton, TN
2010-07-20
A heat pump has a refrigerant loop, a compressor in fluid communication with the refrigerant loop, at least one indoor heat exchanger in fluid communication with the refrigerant loop, and at least one outdoor heat exchanger in fluid communication with the refrigerant loop. The at least one outdoor heat exchanger has a phase change material in thermal communication with the refrigerant loop and in fluid communication with an outdoor environment. Other systems, devices, and methods are described.
Mitigating Communication Delays in Remotely Connected Hardware-in-the-loop Experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cale, James; Johnson, Brian; Dall'Anese, Emiliano
Here, this paper introduces a potential approach for mitigating the effects of communication delays between multiple, closed-loop hardware-in-the-loop experiments which are virtually connected, yet physically separated. The method consists of an analytical method for the compensation of communication delays, along with the supporting computational and communication infrastructure. The control design leverages tools for the design of observers for the compensation of measurement errors in systems with time-varying delays. The proposed methodology is validated through computer simulation and hardware experimentation connecting hardware-in-the-loop experiments conducted between laboratories separated by a distance of over 100 km.
Mitigating Communication Delays in Remotely Connected Hardware-in-the-loop Experiments
Cale, James; Johnson, Brian; Dall'Anese, Emiliano; ...
2018-03-30
Here, this paper introduces a potential approach for mitigating the effects of communication delays between multiple, closed-loop hardware-in-the-loop experiments which are virtually connected, yet physically separated. The method consists of an analytical method for the compensation of communication delays, along with the supporting computational and communication infrastructure. The control design leverages tools for the design of observers for the compensation of measurement errors in systems with time-varying delays. The proposed methodology is validated through computer simulation and hardware experimentation connecting hardware-in-the-loop experiments conducted between laboratories separated by a distance of over 100 km.
A Limited In-Flight Evaluation of the Constant Current Loop Strain Measurement Method
NASA Technical Reports Server (NTRS)
Olney, Candida D.; Collura, Joseph V.
1997-01-01
For many years, the Wheatstone bridge has been used successfully to measure electrical resistance and changes in that resistance. However, the inherent problem of varying lead wire resistance can cause errors when the Wheatstone bridge is used to measure strain in a flight environment. The constant current loop signal-conditioning card was developed to overcome that difficulty. This paper describes a limited evaluation of the constant current loop strain measurement method as used in the F-16XL ship 2 Supersonic Laminar Flow Control flight project. Several identical strain gages were installed in close proximity on a shock fence which was mounted under the left wing of the F- 1 6XL ship 2. Two strain gage bridges were configured using the constant current loop, and two were configured using the Wheatstone bridge circuitry. Flight data comparing the output from the constant current loop configured gages to that of the Wheatstone bridges with respect to signal output, error, and noise are given. Results indicate that the constant current loop strain measurement method enables an increased output, unaffected by lead wire resistance variations, to be obtained from strain gages.
Value of in vivo electrophysiological measurements to evaluate canine small bowel autotransplants.
Meijssen, M A; Heineman, E; de Bruin, R W; Veeze, H J; Bijman, J; de Jonge, H R; ten Kate, F J; Marquet, R L; Molenaar, J C
1991-01-01
This study aimed to develop a non-invasive method for in vivo measurement of the transepithelial potential difference in the canine small bowel and to evaluate this parameter in small bowel autotransplants. In group 0 (control group, n = 4), two intestinal loops were created without disturbing their vascular, neural, and lymphatic supplies. In group I (successful autotransplants, n = 11), two heterotopic small bowel loops were constructed. Long term functional sequelae of vascular, neural, and lymphatic division were studied. Group II (n = 6) consisted of dogs with unsuccessful autotransplants suffering thrombosis of the vascular anastomosis, which resulted in ischaemic small bowel autografts. In group I, values of spontaneous transepithelial potential difference, an index of base line active electrolyte transport, were significantly lower compared with group 0 (p less than 0.05), probably as a result of denervation of the autotransplants. Both theophylline and glucose stimulated potential difference responses, measuring cyclic adenosine monophosphate mediated chloride secretion and sodium coupled glucose absorption respectively, showed negative luminal values in group I at all time points after transplantation. These transepithelial potential difference responses diminished progressively with time. From day 21 onwards both theophylline and glucose stimulated potential difference responses were significantly less than the corresponding responses at day seven (p less than 0.05). Morphometric analysis showed that the reduction of transepithelial potential difference responses preceded degenerative mucosal changes in the heterotopic small bowel autografts. In group II, potential difference responses to theophylline and glucose showed positive luminal values (p<0.01 v group I), probably as a result of passive potassium effusion from necrotic enterocytes. Images Figure 3 PMID:1752464
Dual-circuit, multiple-effect refrigeration system and method
DeVault, Robert C.
1995-01-01
A dual circuit absorption refrigeration system comprising a high temperature single-effect refrigeration loop and a lower temperature double-effect refrigeration loop separate from one another and provided with a double-condenser coupling therebetween. The high temperature condenser of the single-effect refrigeration loop is double coupled to both of the generators in the double-effect refrigeration loop to improve internal heat recovery and a heat and mass transfer additive such as 2-ethyl-1-hexanol is used in the lower temperature double-effect refrigeration loop to improve the performance of the absorber in the double-effect refrigeration loop.
Not simply more of the same: distinguishing between patient heterogeneity and parameter uncertainty.
Vemer, Pepijn; Goossens, Lucas M A; Rutten-van Mölken, Maureen P M H
2014-11-01
In cost-effectiveness (CE) Markov models, heterogeneity in the patient population is not automatically taken into account. We aimed to compare methods of dealing with heterogeneity on estimates of CE, using a case study in chronic obstructive pulmonary disease (COPD). We first present a probabilistic sensitivity analysis (PSA) in which we sampled only from distributions representing parameter uncertainty. This ignores any heterogeneity. Next, we explored heterogeneity by presenting results for subgroups, using a method that samples parameter uncertainty simultaneously with heterogeneity in a single-loop PSA. Finally, we distinguished parameter uncertainty from heterogeneity in a double-loop PSA by performing a nested simulation within each PSA iteration. Point estimates and uncertainty differed substantially between methods. The incremental CE ratio (ICER) ranged from € 4900 to € 13,800. The single-loop PSA led to a substantially different shape of the CE plane and an overestimation of the uncertainty compared with the other 3 methods. The CE plane for the double-loop PSA showed substantially less uncertainty and a stronger negative correlation between the difference in costs and the difference in effects compared with the other methods. This came at the cost of higher calculation times. Not accounting for heterogeneity, subgroup analysis and the double-loop PSA can be viable options, depending on the decision makers' information needs. The single-loop PSA should not be used in CE research. It disregards the fundamental differences between heterogeneity and sampling uncertainty and overestimates uncertainty as a result. © The Author(s) 2014.
OSCILLATION OF NEWLY FORMED LOOPS AFTER MAGNETIC RECONNECTION IN THE SOLAR CHROMOSPHERE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Shuhong; Xiang, Yongyuan, E-mail: shuhongyang@nao.cas.cn
With the high spatial and temporal resolution Hα images from the New Vacuum Solar Telescope, we focus on two groups of loops with an X-shaped configuration in the dynamic chromosphere. We find that the anti-directed loops approach each other and reconnect continually. The connectivity of the loops is changed and new loops are formed and stack together. The stacked loops are sharply bent, implying that they are greatly impacted by the magnetic tension force. When another reconnection process takes place, one new loop is formed and stacks with the previously formed ones. Meanwhile, the stacked loops retract suddenly and movemore » toward the balance position, performing an overshoot movement, which led to an oscillation with an average period of about 45 s. The oscillation of newly formed loops after magnetic reconnection in the chromosphere is observed for the first time. We suggest that the stability of the stacked loops is destroyed due to the attachment of the last new loop and then suddenly retract under the effect of magnetic tension. Because of the retraction, another lower loop is pushed outward and performs an oscillation with a period of about 25 s. The different oscillation periods may be due to their difference in three parameters, i.e., loop length, plasma density, and magnetic field strength.« less
Móricz, K; Gyetvai, B; Bárdos, G
1998-08-01
The aim of this work was to study the effects of benzalkonium chloride (BAC) treatment on the small intestine and its functioning in rats surgically prepared with Thiry-Vella intestinal loop. The loops were treated with either BAC, which ablated much of the myenteric plexus and extrinsic innervation, or with physiological saline (SAL). In vivo drinking experiments were performed to examine the effect on fluid intake and behavioral indices of distending the loop with a balloon. Spontaneous motility and its changes induced by acetylcholine (ACh) and histamine (His) were studied on isolated stripes in vitro. Finally, samples from the loops were examined histologically. Though reduction of the cell number was less than expected and no differences of the thickness of the muscular layer between the two groups was observed, BAC treatment altered the pattern of spontaneous activity and also the sensitivity to ACh and His in isolated stripes. In vivo distension of the SAL-treated loops reduced fluid intake and produced signs of aversivity; these effects were absent in the BAC-treated group. Our results show that despite the differences in the degree of ablation from those obtained by others, BAC treatment can be used to study the mechanisms underlying the effects of the enteral stimuli on the behavior.
Wong, Shi Kang; Patil, Pravinkumar G
2018-03-15
The inferior alveolar nerve (IAN) frequently loops backward before exiting from the mental foramen and spreads several millimeters medially to the foramen. Implant placement in this area may damage the nerve if the anterior loop area is not carefully identified in a radiographic or computed tomography (CT) evaluation. The purpose of this observational study was to measure the prevalence of the presence of the anterior loop and to estimate sex and ethnicity-related variations in anterior loop length in the Malaysian population. A total of 100 cone beam computed tomography (CBCT) Digital Imaging and Communications in Medicine (DICOM) files were selected from a pool of 810 ongoing or completed patients in 3 different ethnic groups: Malay (33), Indian (33), and Chinese (34). The DICOM data were imported into commercial software. The IAN was traced with software along with the anterior loop and part of the incisive nerve. The vertical length of the nerve was estimated from the canal to the opening of the mental foramen from the cross-sectional view and translated to the panoramic view. Measurement was made from this point to the most anterior point of the anterior loop by following the trajectory of the nerve and was repeated on the opposite side. A 2-way mixed analysis of variance (ANOVA) test was carried out to evaluate the sex- and ethnicity-related variations (α=.05). The anterior loop was present in 94% of the 100 participants. Overall anterior loop length (AnLL) ranged between 0.73 and 7.99 mm with a mean length of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side. Among all participants, no statistically significant differences were found between the left and right sides of the mandible (P=.379). Overall, no significant main effect of ethnicity (P=.869) or sex (P=.576) was found on AnLL measurements. Also, with multiple comparisons, no significant effect was found between each pair of ethnic groups. Men in all 3 ethnic groups had greater AnLL than women. The anterior loop was present in 94% of the 100 participants among the 3 major ethnic groups of Malaysia. Overall AnLL ranged between 0.73 and 7.99 mm and mean lengths of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side, with no significant ethnicity- or sex-related variations. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
An integrand reconstruction method for three-loop amplitudes
NASA Astrophysics Data System (ADS)
Badger, Simon; Frellesvig, Hjalte; Zhang, Yang
2012-08-01
We consider the maximal cut of a three-loop four point function with massless kinematics. By applying Gröbner bases and primary decomposition we develop a method which extracts all ten propagator master integral coefficients for an arbitrary triple-box configuration via generalized unitarity cuts. As an example we present analytic results for the three loop triple-box contribution to gluon-gluon scattering in Yang-Mills with adjoint fermions and scalars in terms of three master integrals.
GPSS and Modeling of Computer Communication Networks.
1982-04-01
chains are used to alter the normal "flows" of transactions in a user defined manner. Transaction "flow" may be controlled on the basis of group ...authors refer to loops and rings interchangeably, including those who have designed loop networks with distributed control mechanisms [8,9,10,11,121...that detailed simulation of character by character transmission does not take place; rather, [ control message--data message-- control message! groupings
Geng, Hong Zhi; Nasier, Dilidan; Liu, Bing; Gao, Hua; Xu, Yi Ke
2015-01-01
Introduction Defunctioning loop ileostomy (LI) and loop colostomy (LC) are used widely to protect/treat anastomotic leakage after colorectal surgery. However, it is not known which surgical approach has a lower prevalence of surgical complications after low anterior resection for rectal carcinoma (LARRC). Methods We conducted a literature search of PubMed, MEDLINE, Ovid, Embase and Cochrane databases to identify studies published between 1966 and 2013 focusing on elective surgical complications related to defunctioning LI and LC undertaken to protect a distal rectal anastomosis after LARRC. Results Five studies (two randomized controlled trials, one prospective non-randomized trial, and two retrospective trials) satisfied the inclusion criteria. Outcomes of 1,025 patients (652 LI and 373 LC) were analyzed. After the construction of a LI or LC, there was a significantly lower prevalence of sepsis (p=0.04), prolapse (p=0.03), and parastomal hernia (p=0.02) in LI patients than in LC patients. Also, the prevalence of overall complications was significantly lower in those who received LIs compared with those who received LCs (p<0.0001). After closure of defunctioning loops, there were significantly fewer wound infections (p=0.006) and incisional hernias (p=0.007) in LI patients than in LC patients, but there was no significant difference between the two groups in terms of overall complications. Conclusions The results of this meta-analysis show that a defunctioning LI may be superior to LC with respect to a lower prevalence of surgical complications after LARRC. PMID:26274752
Geng, Hong Zhi; Nasier, Dilidan; Liu, Bing; Gao, Hua; Xu, Yi Ke
2015-10-01
Introduction Defunctioning loop ileostomy (LI) and loop colostomy (LC) are used widely to protect/treat anastomotic leakage after colorectal surgery. However, it is not known which surgical approach has a lower prevalence of surgical complications after low anterior resection for rectal carcinoma (LARRC). Methods We conducted a literature search of PubMed, MEDLINE, Ovid, Embase and Cochrane databases to identify studies published between 1966 and 2013 focusing on elective surgical complications related to defunctioning LI and LC undertaken to protect a distal rectal anastomosis after LARRC. Results Five studies (two randomized controlled trials, one prospective non-randomized trial, and two retrospective trials) satisfied the inclusion criteria. Outcomes of 1,025 patients (652 LI and 373 LC) were analyzed. After the construction of a LI or LC, there was a significantly lower prevalence of sepsis (p=0.04), prolapse (p=0.03), and parastomal hernia (p=0.02) in LI patients than in LC patients. Also, the prevalence of overall complications was significantly lower in those who received LIs compared with those who received LCs (p<0.0001). After closure of defunctioning loops, there were significantly fewer wound infections (p=0.006) and incisional hernias (p=0.007) in LI patients than in LC patients, but there was no significant difference between the two groups in terms of overall complications. Conclusions The results of this meta-analysis show that a defunctioning LI may be superior to LC with respect to a lower prevalence of surgical complications after LARRC.
NASA Astrophysics Data System (ADS)
Dai, Yu; Ding, Mingde
2018-04-01
Recent observations in extreme-ultraviolet (EUV) wavelengths reveal an EUV late phase in some solar flares that is characterized by a second peak in warm coronal emissions (∼3 MK) several tens of minutes to a few hours after the soft X-ray (SXR) peak. Using the model enthalpy-based thermal evolution of loops (EBTEL), we numerically probe the production of EUV late-phase solar flares. Starting from two main mechanisms of producing the EUV late phase, i.e., long-lasting cooling and secondary heating, we carry out two groups of numerical experiments to study the effects of these two processes on the emission characteristics in late-phase loops. In either of the two processes an EUV late-phase solar flare that conforms to the observational criteria can be numerically synthesized. However, the underlying hydrodynamic and thermodynamic evolutions in late-phase loops are different between the two synthetic flare cases. The late-phase peak due to a long-lasting cooling process always occurs during the radiative cooling phase, while that powered by a secondary heating is more likely to take place in the conductive cooling phase. We then propose a new method for diagnosing the two mechanisms based on the shape of EUV late-phase light curves. Moreover, from the partition of energy input, we discuss why most solar flares are not EUV late flares. Finally, by addressing some other factors that may potentially affect the loop emissions, we also discuss why the EUV late phase is mainly observed in warm coronal emissions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ginzburg, N. S., E-mail: ginzburg@appl.sci-nnov.ru; Denisov, G. G.; Vilkov, M. N.
2016-05-15
A periodic train of powerful ultrashort microwave pulses can be generated in electron oscillators with a non-linear saturable absorber installed in the feedback loop. This method of pulse formation resembles the passive mode-locking widely used in laser physics. Nevertheless, there is a specific feature in the mechanism of pulse amplification when consecutive energy extraction from different fractions of a stationary electron beam takes place due to pulse slippage over the beam caused by the difference between the wave group velocity and the electron axial velocity. As a result, the peak power of generated “gigantic” pulses can exceed not only themore » level of steady-state generation but also, in the optimal case, the power of the driving electron beam.« less
Self-diffusion in a system of interacting Langevin particles
NASA Astrophysics Data System (ADS)
Dean, D. S.; Lefèvre, A.
2004-06-01
The behavior of the self-diffusion constant of Langevin particles interacting via a pairwise interaction is considered. The diffusion constant is calculated approximately within a perturbation theory in the potential strength about the bare diffusion constant. It is shown how this expansion leads to a systematic double expansion in the inverse temperature β and the particle density ρ . The one-loop diagrams in this expansion can be summed exactly and we show that this result is exact in the limit of small β and ρβ constants. The one-loop result can also be resummed using a semiphenomenological renormalization group method which has proved useful in the study of diffusion in random media. In certain cases the renormalization group calculation predicts the existence of a diverging relaxation time signaled by the vanishing of the diffusion constant, possible forms of divergence coming from this approximation are discussed. Finally, at a more quantitative level, the results are compared with numerical simulations, in two dimensions, of particles interacting via a soft potential recently used to model the interaction between coiled polymers.
Age group classification and gender detection based on forced expiratory spirometry.
Cosgun, Sema; Ozbek, I Yucel
2015-08-01
This paper investigates the utility of forced expiratory spirometry (FES) test with efficient machine learning algorithms for the purpose of gender detection and age group classification. The proposed method has three main stages: feature extraction, training of the models and detection. In the first stage, some features are extracted from volume-time curve and expiratory flow-volume loop obtained from FES test. In the second stage, the probabilistic models for each gender and age group are constructed by training Gaussian mixture models (GMMs) and Support vector machine (SVM) algorithm. In the final stage, the gender (or age group) of test subject is estimated by using the trained GMM (or SVM) model. Experiments have been evaluated on a large database from 4571 subjects. The experimental results show that average correct classification rate performance of both GMM and SVM methods based on the FES test is more than 99.3 % and 96.8 % for gender and age group classification, respectively.
Mehrpour, Omid; Sheikhazadi, Ardeshir; Barzegar, Afsoon; Husein, Afzal; Malic, Claudia; Sheikhazadi, Elham; Saberi-Anary, Seyed Hossein
2016-01-01
Background Recreational drugs have a significant impact on the lives of drug users, their close families andfriends, as well as their society. Social, psychological, biological, and genetic factors could make a personmore prone to using recreational drugs. Finger and A-B ridges (dermatoglyphics) are formed during the firstand second trimesters of fetal development, under the influence of environmental and genetic factors. Theaim of our study was to investigate and evaluate a possible link between dermatoglyphics and opium usage. Methods The pattern of dermatoglyphics - finger and A-B prints - obtained from a group of opium users(121 patients) was compared to those obtained from a group of opium non-users (121 patients) from Birjand,Iran. The results were analyzed using chi-square, t and Mann–Whitney tests. Findings The results showed that although A-B ridges of palms and fingers in our study group were highercompared to the control group, there was no significant difference between these groups. The only significantdifference was the fingerprint patterns of the left ring finger in the study group, which lacked the arch patternand had less loop patterns. The dominant type of fingerprint in the left ring finger was the whorl. In ouropium user group, the arch and loop fingerprint patterns were heterogeneous and significantly different incomparison with the control group (P < 0.01). Conclusion These findings suggest that a genetic factor may increase the predisposition to recreational drugusage. Further research is required to confirm this possible impact of genetic factors on the addiction process. PMID:27882204
mr: A C++ library for the matching and running of the Standard Model parameters
NASA Astrophysics Data System (ADS)
Kniehl, Bernd A.; Pikelner, Andrey F.; Veretin, Oleg L.
2016-09-01
We present the C++ program library mr that allows us to reliably calculate the values of the running parameters in the Standard Model at high energy scales. The initial conditions are obtained by relating the running parameters in the MS bar renormalization scheme to observables at lower energies with full two-loop precision. The evolution is then performed in accordance with the renormalization group equations with full three-loop precision. Pure QCD corrections to the matching and running are included through four loops. We also provide a Mathematica interface for this program library. Catalogue identifier: AFAI_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AFAI_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU General Public License, version 3 No. of lines in distributed program, including test data, etc.: 517613 No. of bytes in distributed program, including test data, etc.: 2358729 Distribution format: tar.gz Programming language: C++. Computer: IBM PC. Operating system: Linux, Mac OS X. RAM: 1 GB Classification: 11.1. External routines: TSIL [1], OdeInt [2], boost [3] Nature of problem: The running parameters of the Standard Model renormalized in the MS bar scheme at some high renormalization scale, which is chosen by the user, are evaluated in perturbation theory as precisely as possible in two steps. First, the initial conditions at the electroweak energy scale are evaluated from the Fermi constant GF and the pole masses of the W, Z, and Higgs bosons and the bottom and top quarks including the full two-loop threshold corrections. Second, the evolution to the high energy scale is performed by numerically solving the renormalization group evolution equations through three loops. Pure QCD corrections to the matching and running are included through four loops. Solution method: Numerical integration of analytic expressions Additional comments: Available for download from URL: http://apik.github.io/mr/. The MathLink interface is tested to work with Mathematica 7-9 and, with an additional flag, also with Mathematica 10 under Linux and with Mathematica 10 under Mac OS X. Running time: less than 1 second References: [1] S. P. Martin and D. G. Robertson, Comput. Phys. Commun. 174 (2006) 133-151 [hep-ph/0501132]. [2] K. Ahnert and M. Mulansky, AIP Conf. Proc. 1389 (2011) 1586-1589 [arxiv:1110.3397 [cs.MS
Kato, Tomoko S; Nakamura, Hiroshi; Murata, Mai; Kuroda, Kishio; Suzuki, Hitoshi; Yokoyama, Yasutaka; Shimada, Akie; Matsushita, Satoshi; Yamamoto, Taira; Amano, Atsushi
2016-09-13
Adequate fluid management is an important component of patient care following cardiac surgery. Our aim in this study was to determine the benefits of tolvaptan, an oral selective vasopressin-2 receptor antagonist that causes electrolyte-free water diuresis, in postoperative fluid management. We prospectively examined the effect of tolvaptan on renal excretion of electrolytes and urea nitrogen in cardiac surgery patients. Patients undergoing coronary artery bypass surgery were randomized to receive conventional loop diuretics (Group C, n = 30) or conventional loop diuretic therapy plus tolvaptan (Group T, n = 27). Fractional excretions of sodium (FENA), potassium (FEK) and urea nitrogen (FEUN) were measured in both groups during post-surgical hospitalization. Urine output was greater with tolvaptan (Group T) than without it (Group C), and some patients in Group C required intravenous as well as oral loop diuretics. Serum sodium concentrations decreased after surgery in Group C, but were unchanged in Group T (postoperative day [POD] 3, 139.8 ± 3.5 vs. 142.3 ± 2.6 mEq/L, p = 0.006). However, postoperative FENA values in Group C did not decrease, and the values were similar in both groups. Serum potassium levels remained lower and FEK values remained higher than the preoperative values, but only in Group C (all p < 0.05). BUN increased postoperatively in both groups, but it remained higher than its preoperative value only in Group C (all p < 0.01). Group T showed an initial increase in BUN, which peaked and then returned to its preoperative value within a week. The FEUN increased postoperatively in both groups, but the change was more pronounced in Group T (POD7, 52.7 ± 9.3 vs. 58.2 ± 6.5 %, p = 0.025). Renal excretion of sodium and potassium reflects the changes in serum concentration in patients treated with tolvaptan. Patients treated only with loop diuretics showed a continuous excretion of sodium and potassium that led to electrolyte imbalance, whereas the combination of loop diuretics and tolvaptan increased renal urea nitrogen elimination. Tolvaptan therefore appears to be an effective diuretic that minimally affects serum electrolytes while adequately promoting the elimination of urea nitrogen from the kidneys in patients undergoing coronary artery bypass surgery. The present study is registered with the UMIN Clinical Trials Registry (ID: UMIN000011039 ).
NASA Technical Reports Server (NTRS)
Waszak, M. R.; Schmidt, D. S.
1985-01-01
As aircraft become larger and lighter due to design requirements for increased payload and improved fuel efficiency, they will also become more flexible. For highly flexible vehicles, the handling qualities may not be accurately predicted by conventional methods. This study applies two analysis methods to a family of flexible aircraft in order to investigate how and when structural (especially dynamic aeroelastic) effects affect the dynamic characteristics of aircraft. The first type of analysis is an open loop model analysis technique. This method considers the effects of modal residue magnitudes on determining vehicle handling qualities. The second method is a pilot in the loop analysis procedure that considers several closed loop system characteristics. Volume 1 consists of the development and application of the two analysis methods described above.
Improved Beam Jitter Control Methods for High Energy Laser Systems
2009-12-01
Figure 16. The inner loop is a rate control loop composed of a gimbal, power amplifier , controller, and servo components (gyro, motor, and encoder...system characterization experiments 1. WFOV Control Loop a. Resonance Frequency Random signals were applied to the power amplifier and output...Loop Stabilization By applying a disturbance to the input of the power amplifier and measuring torque error, one is able to determine the torque
Oh, Heung-Kwon; Han, Eon Chul; Song, Yoon Suk; Seo, Mi Sun; Ryoo, Seung-Bum; Jeong, Seung-Yong; Park, Kyu Joo
2015-01-01
A temporary defunctioning loop ileostomy is frequently created during low colorectal or coloanal anastomosis to prevent peritoneal sepsis associated with anastomotic leakage. We investigated whether routine support bridge placement prevents stoma retraction after the formation of a loop ileostomy. Prospective, nonrandomized trial. The study sample comprised 32 consecutive patients who underwent defunctioning loop ileostomy at an academic tertiary care center in Seoul Korea from February to September 2010. Patients were nonrandomly allocated to "no bridge," "short-term bridge" (1 week), and "long-term bridge" (3 weeks) groups based on the surgeon's clinical judgment. Group differences in stoma height changes over time were analyzed. Subjects' mean age was 59.5 (range: 43-82) years, and the male-to-female ratio was 2.2:1.0. The mean heights of the stoma on postoperative day 2 and postoperative month 3, respectively, were 1.07 ± 0.16 cm (mean ± SD) and 0.81 ± 0.17 cm in the no-bridge group, 1.70 ± 0.29 cm and 1.21 ± 0.18 cm in the short-term bridge group, and 1.18 ± 0.16 cm and 1.01 ± 0.20 cm in the long-term bridge group. The changes in the stoma height 3 months after the surgery showed no statistically significant differences among the groups (P = .430). Stoma Quality of Life scores at 3 weeks (47.4 vs 46.1; P = .730) were similar for patients with and without bridges. However, a significantly greater number of patients with bridges reported difficulty with pouch changes compared to those without bridges (72.7% vs 14.3%; P = .002). Routine use of support bridges during loop ileostomy is unnecessary and inconvenient to patients. If a support bridge must be used, it can be removed early.
Method of Implementing Digital Phase-Locked Loops
NASA Technical Reports Server (NTRS)
Stephens, Scott A. (Inventor); Thomas, J. Brooks (Inventor)
1997-01-01
In a new formulation for digital phase-locked loops, loop-filter constants are determined from loop roots that can each be selectively placed in the s-plane on the basis of a new set of parameters, each with simple and direct physical meaning in terms of loop noise bandwidth, root-specific decay rate, and root-specific damping. Loops of first to fourth order are treated in the continuous-update approximation (B(sub L)T approaches 0) and in a discrete-update formulation with arbitrary B(sub L)T. Deficiencies of the continuous-update approximation in large-B(sub L)T applications are avoided in the new discrete-update formulation.
Improving materials and methods for installing inductive loop detectors : final report.
DOT National Transportation Integrated Search
1986-06-01
This report is the final report of this research project. It describes a compiling of materials utilized by various agencies for use in formation of inductive loop detectors. It further lists methods by which different agencies install materials in o...
Yamunadevi, Andamuthu; Dineshshankar, Janardhanam; Banu, Safeena; Fathima, Nilofar; Ganapathy; Yoithapprabhunath, Thukanayakanpalayam Ragunathan; Maheswaran, Thangadurai; Ilayaraja, Vadivel
2015-01-01
Dermatoglyphic patterns, which are regularly used in judicial and legal investigations, can be valuable in the diagnosis of many diseases associated with genetic disorders. Dental caries although of infectious origin, may have a genetic predisposition. Hence, we evaluated the correlation between dental caries and dermatoglyphic patterns among subjects with and without dental caries and evaluated its association with environmental factors such as salivary pH. Totally, 76 female students within the age group of 18-23 years were clinically examined, and their decayed, missing, filled teeth (DMFT) score and oral hygiene index-simplified were recorded. Based on their DMFT score, they were divided into following three groups; group I (n = 16, DMFT score = 0), group II (n = 30, DMFT score <5), and group III (n = 30, DMFT score ≥5). Their fingerprint patterns and salivary pH were recorded and analyzed using descriptive statistics. Dermatoglyphic pattern distribution in caries-free group showed more ulnar loops than high caries group (group III) while high caries group showed more whorl patterns. Presence of whorl with double loop, whorl within a loop was associated with high DMFT score. The total finger ridge count was lower in caries group. The mean salivary pH was higher in caries-free group than high caries group. Thus, we conclude that dermatoglyphic patterns may be potential diagnostic tool for detecting patients prone to develop dental caries.
Open-loop-feedback control of serum drug concentrations: pharmacokinetic approaches to drug therapy.
Jelliffe, R W
1983-01-01
Recent developments to optimize open-loop-feedback control of drug dosage regimens, generally applicable to pharmacokinetically oriented therapy with many drugs, involve computation of patient-individualized strategies for obtaining desired serum drug concentrations. Analyses of past therapy are performed by least squares, extended least squares, and maximum a posteriori probability Bayesian methods of fitting pharmacokinetic models to serum level data. Future possibilities for truly optimal open-loop-feedback therapy with full Bayesian methods, and conceivably for optimal closed-loop therapy in such data-poor clinical situations, are also discussed. Implementation of these various therapeutic strategies, using automated, locally controlled infusion devices, has also been achieved in prototype form.
Uncertainty loops in travel-time tomography from nonlinear wave physics.
Galetti, Erica; Curtis, Andrew; Meles, Giovanni Angelo; Baptie, Brian
2015-04-10
Estimating image uncertainty is fundamental to guiding the interpretation of geoscientific tomographic maps. We reveal novel uncertainty topologies (loops) which indicate that while the speeds of both low- and high-velocity anomalies may be well constrained, their locations tend to remain uncertain. The effect is widespread: loops dominate around a third of United Kingdom Love wave tomographic uncertainties, changing the nature of interpretation of the observed anomalies. Loops exist due to 2nd and higher order aspects of wave physics; hence, although such structures must exist in many tomographic studies in the physical sciences and medicine, they are unobservable using standard linearized methods. Higher order methods might fruitfully be adopted.
Electron Injection by E-Field Drift and its Application in Starting-up Tokamaks at Low Loop Voltage
NASA Astrophysics Data System (ADS)
Pan, Yuan; Yan, Xiao-Lin; Liu, Bao-Hua
2003-05-01
We propose an innovative method of electron injection by E-field drift into a plasma device and discuss its application in starting-up tokamak plasmas at low loop voltage. The experimental results obtained from HT-6M Tokamak are also presented. The breakdown loop voltage is obviously reduced and the discharge performance is improved by using the electron injection method. It could be applied to some other types of plasma device.
NASA Technical Reports Server (NTRS)
Vanlunteren, A.; Stassen, H. G.
1973-01-01
Parameter estimation techniques are discussed with emphasis on unbiased estimates in the presence of noise. A distinction between open and closed loop systems is made. A method is given based on the application of external forcing functions consisting of a sun of sinusoids; this method is thus based on the estimation of Fourier coefficients and is applicable for models with poles and zeros in open and closed loop systems.
Closed-loop bird-computer interactions: a new method to study the role of bird calls.
Lerch, Alexandre; Roy, Pierre; Pachet, François; Nagle, Laurent
2011-03-01
In the field of songbird research, many studies have shown the role of male songs in territorial defense and courtship. Calling, another important acoustic communication signal, has received much less attention, however, because calls are assumed to contain less information about the emitter than songs do. Birdcall repertoire is diverse, and the role of calls has been found to be significant in the area of social interaction, for example, in pair, family, and group cohesion. However, standard methods for studying calls do not allow precise and systematic study of their role in communication. We propose herein a new method to study bird vocal interaction. A closed-loop computer system interacts with canaries, Serinus canaria, by (1) automatically classifying two basic types of canary vocalization, single versus repeated calls, as they are produced by the subject, and (2) responding with a preprogrammed call type recorded from another bird. This computerized animal-machine interaction requires no human interference. We show first that the birds do engage in sustained interactions with the system, by studying the rate of single and repeated calls for various programmed protocols. We then show that female canaries differentially use single and repeated calls. First, they produce significantly more single than repeated calls, and second, the rate of single calls is associated with the context in which they interact, whereas repeated calls are context independent. This experiment is the first illustration of how closed-loop bird-computer interaction can be used productively to study social relationships. © Springer-Verlag 2010
Inverse spin Hall effect in a closed loop circuit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omori, Y.; Auvray, F.; Wakamura, T.
We present measurements of inverse spin Hall effects (ISHEs), in which the conversion of a spin current into a charge current via the ISHE is detected not as a voltage in a standard open circuit but directly as the charge current generated in a closed loop. The method is applied to the ISHEs of Bi-doped Cu and Pt. The derived expression of ISHE for the loop structure can relate the charge current flowing into the loop to the spin Hall angle of the SHE material and the resistance of the loop.
Network clustering and community detection using modulus of families of loops.
Shakeri, Heman; Poggi-Corradini, Pietro; Albin, Nathan; Scoglio, Caterina
2017-01-01
We study the structure of loops in networks using the notion of modulus of loop families. We introduce an alternate measure of network clustering by quantifying the richness of families of (simple) loops. Modulus tries to minimize the expected overlap among loops by spreading the expected link usage optimally. We propose weighting networks using these expected link usages to improve classical community detection algorithms. We show that the proposed method enhances the performance of certain algorithms, such as spectral partitioning and modularity maximization heuristics, on standard benchmarks.
System and method of designing models in a feedback loop
Gosink, Luke C.; Pulsipher, Trenton C.; Sego, Landon H.
2017-02-14
A method and system for designing models is disclosed. The method includes selecting a plurality of models for modeling a common event of interest. The method further includes aggregating the results of the models and analyzing each model compared to the aggregate result to obtain comparative information. The method also includes providing the information back to the plurality of models to design more accurate models through a feedback loop.
Nickel titanium T-loop wire dimensions for en masse retraction.
Almeida, Layene; Ribeiro, Alexandre; Parsekian Martins, Renato; Viecilli, Rodrigo; Parsekian Martins, Lídia
2016-09-01
To compare the force system produced by nickel-titanium T-loop springs made with wires of different dimensions. Thirty compound T-loop springs were divided into three groups according to the dimensions of the nickel-titanium wire used for its design: 0.016" × 0.022", 0.017" × 0.025", and 0.018" × 0.025". The loops were tested on the Orthodontic Force Tester machine at an interbracket distance of 23 mm and activated 9 mm. The force in the y-axis and the moment in the x-axis were registered while the calculated moment to force ratio was recorded at each .5 mm of deactivation. The data were analyzed by three analyses of variance of repeated measures to detect differences and interactions between deactivation and wire size on force, moment, and moment-force ratios (M/F). All groups had significantly different forces (P < .001). The 0.016" × 0.022" wire produced 1.78N of force while the 0.017" × 0.025" and the 0.018" × 0.025" produced 2.81 N and 3.25 N, respectively. The 0.016" × 0.022" wire produced lower moments (11.6 Nmm) than the 0.017" × 0.025" and 0.018" × 0.025" wires, which produced similar moments (13.9 Nmm and 14.4Nmm, respectively). The M/F produced was different for all groups; 0.016" × 0.022" T-loops produced 6.7 mm while the 0.017" × 0.025" and 0.018" × 0.025" T-loops produced 5.0 mm and 4.5 mm, respectively. An interaction was detected for all variables between deactivation and groups. The larger wires tested produced higher forces with slight increase on the moments, but the M/F produced by the 0.016" × 0.022" wire was the highest found.
ENVIRONMENTAL BENIGN MITIGATION OF MICROBIOLOGICALLY INFLUENCED CORROSION (MIC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
J.R. Paterek; G. Husmillo; V. Trbovic
The overall program objective is to develop and evaluate environmental benign agents or products that are effective in the prevention, inhibition, and mitigation of microbially influenced corrosion (MIC) in the internal surfaces of metallic natural gas pipelines. The goal is one or more environmental benign, a.k.a. ''green'' products that can be applied to maintain the structure and dependability of the natural gas infrastructure. The technical approach for this quarter were isolation and cultivation of MIC-causing microorganisms from corroded pipeline samples, optimizing parameters in the laboratory-scale corrosion test loop system and testing the effective concentrations of Capsicum sp. extracts to verifymore » the extent of corrosion on metal coupons by batch culture method. A total of 22 strains from the group of heterotrophic, acid producing, denitrifying and sulfate reducing bacteria were isolated from the gas pipeline samples obtained from Northern Indiana Public Service Company in Trenton, Indiana. They were purified and will be sent out for identification. Bacterial strains of interest were used in antimicrobial screenings and test loop experiments. Parameters for the laboratory-scale test loop system such as gas and culture medium flow rate; temperature; inoculation period; and length of incubation were established. Batch culture corrosion study against Desulfovibrio vulgaris showed that one (S{sub 1}M) out of the four Capsicum sp. extracts tested was effective in controlling the corrosion rate in metal coupons by 33.33% when compared to the untreated group.« less
Using systems science to understand the determinants of inequities in healthy eating
Pescud, Melanie; Malbon, Eleanor; Lee, Amanda; Carter, Robert; Greenfield, Joanne; Cobcroft, Megan; Potter, Jane; Rychetnik, Lucie; Meertens, Beth
2017-01-01
Introduction Systems thinking has emerged in recent years as a promising approach to understanding and acting on the prevention and amelioration of non-communicable disease. However, the evidence on inequities in non-communicable diseases and their risks factors, particularly diet, has not been examined from a systems perspective. We report on an approach to developing a system oriented policy actor perspective on the multiple causes of inequities in healthy eating. Methods Collaborative conceptual modelling workshops were held in 2015 with an expert group of representatives from government, non-government health organisations and academia in Australia. The expert group built a systems model using a system dynamics theoretical perspective. The model developed from individual mind maps to pair blended maps, before being finalised as a causal loop diagram. Results The work of the expert stakeholders generated a comprehensive causal loop diagram of the determinants of inequity in healthy eating (the HE2 Diagram). This complex dynamic system has seven sub-systems: (1) food supply and environment; (2) transport; (3) housing and the built environment; (4) employment; (5) social protection; (6) health literacy; and (7) food preferences. Discussion The HE2 causal loop diagram illustrates the complexity of determinants of inequities in healthy eating. This approach, both the process of construction and the final visualisation, can provide the basis for planning the prevention and amelioration of inequities in healthy eating that engages with multiple levels of causes and existing policies and programs. PMID:29190662
Polymer diffusion in quenched disorder: A renormalization group approach
NASA Astrophysics Data System (ADS)
Ebert, Ute
1996-01-01
We study the diffusion of polymers through quenched short-range correlated random media by renormalization group (RG) methods, which allow us to derive universal predictions in the limit of long chains and weak disorder. We take local quenched random potentials with second moment v and the excluded-volume interaction u of the chain segments into account. We show that our model contains the relevant features of polymer diffusion in random media in the RG sense if we focus on the local entropic effects rather than on the topological constraints of a quenched random medium. The dynamic generating functional and the general structure of its perturbation expansion in u and v are derived. The distribution functions for the center-of-mass motion and the internal modes of one chain and for the correlation of the center of mass motions of two chains are calculated to one-loop order. The results allow for sufficient cross-checks to have trust in the one-loop renormalizability of the model. The general structure as well as the one-loop results of the integrated RG flow of the parameters are discussed. Universal results can be found for the effective static interaction w≔u-v≥0 and for small effective disorder couplingbar v(l) on the intermediate length scale l. As a first physical prediction from our analysis, we determine the general nonlinear scaling form of the chain diffusion constant and evaluate it explicitly as[Figure not available: see fulltext.] forbar v(l) ≪ 1.
Sullivan, Edith V; Rose, Jessica; Pfefferbaum, Adolf
2010-03-01
Excessive sway during quiet standing is a common sequela of chronic alcoholism even with prolonged sobriety. Whether alcoholic men and women who have remained abstinent from alcohol for weeks to months differ from each other in the degree of residual postural instability and biomechanical control mechanisms has not been directly tested. We used a force platform to characterize center-of-pressure biomechanical features of postural sway, with and without stabilizing conditions from touch, vision, and stance, in 34 alcoholic men, 15 alcoholic women, 22 control men, and 29 control women. Groups were matched in age (49.4 years), general intelligence, socioeconomic status, and handedness. Each alcoholic group was sober for an average of 75 days. Analysis of postural sway when using all 3 stabilizing conditions versus none revealed diagnosis and sex differences in ability to balance. Alcoholics had significantly longer sway paths, especially in the anterior-posterior direction, than controls when maintaining erect posture without balance aids. With stabilizing conditions the sway paths of all groups shortened significantly, especially those of alcoholic men, who demonstrated a 3.1-fold improvement in sway path difference between the easiest and most challenging conditions; the remaining 3 groups, each showed a approximately 2.4-fold improvement. Application of a mechanical model to partition sway paths into open-loop and closed-loop postural control systems revealed that the sway paths of the alcoholic men but not alcoholic women were characterized by greater short-term (open-loop) diffusion coefficients without aids, often associated with muscle stiffening response. With stabilizing factors, all 4 groups showed similar long-term (closed loop) postural control. Correlations between cognitive abilities and closed-loop sway indices were more robust in alcoholic men than alcoholic women. Reduction in sway and closed-loop activity during quiet standing with stabilizing factors shows some differential expression in men and women with histories of alcohol dependence. Nonetheless, enduring deficits in postural instability of both alcoholic men and alcoholic women suggest persisting liability for falling.
The diversity of H3 loops determines the antigen-binding tendencies of antibody CDR loops.
Tsuchiya, Yuko; Mizuguchi, Kenji
2016-04-01
Of the complementarity-determining regions (CDRs) of antibodies, H3 loops, with varying amino acid sequences and loop lengths, adopt particularly diverse loop conformations. The diversity of H3 conformations produces an array of antigen recognition patterns involving all the CDRs, in which the residue positions actually in contact with the antigen vary considerably. Therefore, for a deeper understanding of antigen recognition, it is necessary to relate the sequence and structural properties of each residue position in each CDR loop to its ability to bind antigens. In this study, we proposed a new method for characterizing the structural features of the CDR loops and obtained the antigen-binding ability of each residue position in each CDR loop. This analysis led to a simple set of rules for identifying probable antigen-binding residues. We also found that the diversity of H3 loop lengths and conformations affects the antigen-binding tendencies of all the CDR loops. © 2016 The Protein Society.
NASA Technical Reports Server (NTRS)
Gibson, J. S.; Rosen, I. G.
1985-01-01
In the optimal linear quadratic regulator problem for finite dimensional systems, the method known as an alpha-shift can be used to produce a closed-loop system whose spectrum lies to the left of some specified vertical line; that is, a closed-loop system with a prescribed degree of stability. This paper treats the extension of the alpha-shift to hereditary systems. As infinite dimensions, the shift can be accomplished by adding alpha times the identity to the open-loop semigroup generator and then solving an optimal regulator problem. However, this approach does not work with a new approximation scheme for hereditary control problems recently developed by Kappel and Salamon. Since this scheme is among the best to date for the numerical solution of the linear regulator problem for hereditary systems, an alternative method for shifting the closed-loop spectrum is needed. An alpha-shift technique that can be used with the Kappel-Salamon approximation scheme is developed. Both the continuous-time and discrete-time problems are considered. A numerical example which demonstrates the feasibility of the method is included.
NASA Technical Reports Server (NTRS)
Gibson, J. S.; Rosen, I. G.
1987-01-01
In the optimal linear quadratic regulator problem for finite dimensional systems, the method known as an alpha-shift can be used to produce a closed-loop system whose spectrum lies to the left of some specified vertical line; that is, a closed-loop system with a prescribed degree of stability. This paper treats the extension of the alpha-shift to hereditary systems. As infinite dimensions, the shift can be accomplished by adding alpha times the identity to the open-loop semigroup generator and then solving an optimal regulator problem. However, this approach does not work with a new approximation scheme for hereditary control problems recently developed by Kappel and Salamon. Since this scheme is among the best to date for the numerical solution of the linear regulator problem for hereditary systems, an alternative method for shifting the closed-loop spectrum is needed. An alpha-shift technique that can be used with the Kappel-Salamon approximation scheme is developed. Both the continuous-time and discrete-time problems are considered. A numerical example which demonstrates the feasibility of the method is included.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beau, Mathieu, E-mail: mbeau@stp.dias.ie; Savoie, Baptiste, E-mail: baptiste.savoie@gmail.com
2014-05-15
In this paper, we rigorously investigate the reduced density matrix (RDM) associated to the ideal Bose gas in harmonic traps. We present a method based on a sum-decomposition of the RDM allowing to treat not only the isotropic trap, but also general anisotropic traps. When focusing on the isotropic trap, the method is analogous to the loop-gas approach developed by Mullin [“The loop-gas approach to Bose-Einstein condensation for trapped particles,” Am. J. Phys. 68(2), 120 (2000)]. Turning to the case of anisotropic traps, we examine the RDM for some anisotropic trap models corresponding to some quasi-1D and quasi-2D regimes. Formore » such models, we bring out an additional contribution in the local density of particles which arises from the mesoscopic loops. The close connection with the occurrence of generalized-Bose-Einstein condensation is discussed. Our loop-gas-like approach provides relevant information which can help guide numerical investigations on highly anisotropic systems based on the Path Integral Monte Carlo method.« less
Innovative hybrid pile oscillator technique in the Minerve reactor: open loop vs. closed loop
NASA Astrophysics Data System (ADS)
Geslot, Benoit; Gruel, Adrien; Bréaud, Stéphane; Leconte, Pierre; Blaise, Patrick
2018-01-01
Pile oscillator techniques are powerful methods to measure small reactivity worth of isotopes of interest for nuclear data improvement. This kind of experiments has long been implemented in the Mineve experimental reactor, operated by CEA Cadarache. A hybrid technique, mixing reactivity worth estimation and measurement of small changes around test samples is presented here. It was made possible after the development of high sensitivity miniature fission chambers introduced next to the irradiation channel. A test campaign, called MAESTRO-SL, took place in 2015. Its objective was to assess the feasibility of the hybrid method and investigate the possibility to separate mixed neutron effects, such as fission/capture or scattering/capture. Experimental results are presented and discussed in this paper, which focus on comparing two measurements setups, one using a power control system (closed loop) and another one where the power is free to drift (open loop). First, it is demonstrated that open loop is equivalent to closed loop. Uncertainty management and methods reproducibility are discussed. Second, results show that measuring the flux depression around oscillated samples provides valuable information regarding partial neutron cross sections. The technique is found to be very sensitive to the capture cross section at the expense of scattering, making it very useful to measure small capture effects of highly scattering samples.
Nucleic Acid Detection Methods
Smith, Cassandra L.; Yaar, Ron; Szafranski, Przemyslaw; Cantor, Charles R.
1998-05-19
The invention relates to methods for rapidly determining the sequence and/or length a target sequence. The target sequence may be a series of known or unknown repeat sequences which are hybridized to an array of probes. The hybridized array is digested with a single-strand nuclease and free 3'-hydroxyl groups extended with a nucleic acid polymerase. Nuclease cleaved heteroduplexes can be easily distinguish from nuclease uncleaved heteroduplexes by differential labeling. Probes and target can be differentially labeled with detectable labels. Matched target can be detected by cleaving resulting loops from the hybridized target and creating free 3-hydroxyl groups. These groups are recognized and extended by polymerases added into the reaction system which also adds or releases one label into solution. Analysis of the resulting products using either solid phase or solution. These methods can be used to detect characteristic nucleic acid sequences, to determine target sequence and to screen for genetic defects and disorders. Assays can be conducted on solid surfaces allowing for multiple reactions to be conducted in parallel and, if desired, automated.
A tutorial on the LQG/LTR method. [Linear Quadratic Gaussian/Loop Transfer Recovery
NASA Technical Reports Server (NTRS)
Athans, M.
1986-01-01
In this paper the so-called Linear-Quadratic-Gaussian method with Loop-Transfer-Recovery is surveyed. The objective is to provide a pragmatic exposition, with special emphasis on the step-by-step characteristics for designing multivariable feedback control systems.
Su, Fei; Wang, Jiang; Niu, Shuangxia; Li, Huiyan; Deng, Bin; Liu, Chen; Wei, Xile
2018-02-01
The efficacy of deep brain stimulation (DBS) for Parkinson's disease (PD) depends in part on the post-operative programming of stimulation parameters. Closed-loop stimulation is one method to realize the frequent adjustment of stimulation parameters. This paper introduced the nonlinear predictive control method into the online adjustment of DBS amplitude and frequency. This approach was tested in a computational model of basal ganglia-thalamic network. The autoregressive Volterra model was used to identify the process model based on physiological data. Simulation results illustrated the efficiency of closed-loop stimulation methods (amplitude adjustment and frequency adjustment) in improving the relay reliability of thalamic neurons compared with the PD state. Besides, compared with the 130Hz constant DBS the closed-loop stimulation methods can significantly reduce the energy consumption. Through the analysis of inter-spike-intervals (ISIs) distribution of basal ganglia neurons, the evoked network activity by the closed-loop frequency adjustment stimulation was closer to the normal state. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Del Vescovo, D.; D'Ambrogio, W.
1995-01-01
A frequency domain method is presented to design a closed-loop control for vibration reduction flexible mechanisms. The procedure is developed on a single-link flexible arm, driven by one rotary degree of freedom servomotor, although the same technique may be applied to similar systems such as supports for aerospace antennae or solar panels. The method uses the structural frequency response functions (FRFs), thus avoiding system identification, that produces modeling uncertainties. Two closed-loops are implemented: the inner loop uses acceleration feedback with the aim of making the FRF similar to that of an equivalent rigid link; the outer loop feeds back displacements to achieve a fast positioning response and null steady state error. In both cases, the controller type is established a priori, while actual characteristics are defined by an optimisation procedure in which the relevant FRF is constrained into prescribed bounds and stability is taken into account.
A novel double loop control model design for chemical unstable processes.
Cong, Er-Ding; Hu, Ming-Hui; Tu, Shan-Tung; Xuan, Fu-Zhen; Shao, Hui-He
2014-03-01
In this manuscript, based on Smith predictor control scheme for unstable process in industry, an improved double loop control model is proposed for chemical unstable processes. Inner loop is to stabilize integrating the unstable process and transform the original process to first-order plus pure dead-time dynamic stable process. Outer loop is to enhance the performance of set point response. Disturbance controller is designed to enhance the performance of disturbance response. The improved control system is simple with exact physical meaning. The characteristic equation is easy to realize stabilization. Three controllers are separately design in the improved scheme. It is easy to design each controller and good control performance for the respective closed-loop transfer function separately. The robust stability of the proposed control scheme is analyzed. Finally, case studies illustrate that the improved method can give better system performance than existing design methods. © 2013 ISA Published by ISA All rights reserved.
Regularization with numerical extrapolation for finite and UV-divergent multi-loop integrals
NASA Astrophysics Data System (ADS)
de Doncker, E.; Yuasa, F.; Kato, K.; Ishikawa, T.; Kapenga, J.; Olagbemi, O.
2018-03-01
We give numerical integration results for Feynman loop diagrams such as those covered by Laporta (2000) and by Baikov and Chetyrkin (2010), and which may give rise to loop integrals with UV singularities. We explore automatic adaptive integration using multivariate techniques from the PARINT package for multivariate integration, as well as iterated integration with programs from the QUADPACK package, and a trapezoidal method based on a double exponential transformation. PARINT is layered over MPI (Message Passing Interface), and incorporates advanced parallel/distributed techniques including load balancing among processes that may be distributed over a cluster or a network/grid of nodes. Results are included for 2-loop vertex and box diagrams and for sets of 2-, 3- and 4-loop self-energy diagrams with or without UV terms. Numerical regularization of integrals with singular terms is achieved by linear and non-linear extrapolation methods.
Unmixing Magnetic Hysteresis Loops
NASA Astrophysics Data System (ADS)
Heslop, D.; Roberts, A. P.
2012-04-01
Magnetic hysteresis loops provide important information in rock and environmental magnetic studies. Natural samples often contain an assemblage of magnetic particles composed of components with different origins. Each component potentially carries important environmental information. Hysteresis loops, however, provide information concerning the bulk magnetic assemblage, which makes it difficult to isolate the specific contributions from different sources. For complex mineral assemblages an unmixing strategy with which to separate hysteresis loops into their component parts is therefore essential. Previous methods to unmix hysteresis data have aimed at separating individual loops into their constituent parts using libraries of type-curves thought to correspond to specific mineral types. We demonstrate an alternative approach, which rather than decomposing a single loop into monomineralic contributions, examines a collection of loops to determine their constituent source materials. These source materials may themselves be mineral mixtures, but they provide a genetically meaningful decomposition of a magnetic assemblage in terms of the processes that controlled its formation. We show how an empirically derived hysteresis mixing space can be created, without resorting to type-curves, based on the co-variation within a collection of measured loops. Physically realistic end-members, which respect the expected behaviour and symmetries of hysteresis loops, can then be extracted from the mixing space. These end-members allow the measured loops to be described as a combination of invariant parts that are assumed to represent the different sources in the mixing model. Particular attention is paid to model selection and estimating the complexity of the mixing model, specifically, how many end-members should be included. We demonstrate application of this approach using lake sediments from Butte Valley, northern California. Our method successfully separates the hysteresis loops into sources with a variety of terrigenous and authigenic origins.
Fujimoto, Takeshi; Nakano, Shu-ichi; Sugimoto, Naoki; Miyoshi, Daisuke
2013-01-31
We systematically investigated the effects of loop length on the conformation, thermodynamic stability, and hydration of DNA G-quadruplexes under dilute and molecular crowding conditions in the presence of Na(+). Structural analysis showed that molecular crowding induced conformational switches of oligonucleotides with the longer guanine stretch and the shorter thymine loop. Thermodynamic parameters further demonstrated that the thermodynamic stability of G-quadruplexes increased by increasing the loop length from two to four, whereas it decreased by increasing the loop length from four to six. Interestingly, we found by osmotic pressure analysis that the number of water molecules released from the G-quadruplex decreased with increasing thermodynamic stability. We assumed that base-stacking interactions within the loops not only stabilized the whole G-quadruplex structure but also created hydration sites by accumulating nucleotide functional groups. The molecular crowding effects on the stability of G-quadruplexes composed of abasic sites, which reduce the stacking interactions at the loops, further demonstrated that G-quadruplexes with fewer stacking interactions within the loops released a larger number of water molecules upon folding. These results showed that the stacking interactions within the loops determined the thermodynamic stability and hydration of the whole G-quadruplex.
Analysis of Physicochemical and Structural Properties Determining HIV-1 Coreceptor Usage
Bozek, Katarzyna; Lengauer, Thomas; Sierra, Saleta; Kaiser, Rolf; Domingues, Francisco S.
2013-01-01
The relationship of HIV tropism with disease progression and the recent development of CCR5-blocking drugs underscore the importance of monitoring virus coreceptor usage. As an alternative to costly phenotypic assays, computational methods aim at predicting virus tropism based on the sequence and structure of the V3 loop of the virus gp120 protein. Here we present a numerical descriptor of the V3 loop encoding its physicochemical and structural properties. The descriptor allows for structure-based prediction of HIV tropism and identification of properties of the V3 loop that are crucial for coreceptor usage. Use of the proposed descriptor for prediction results in a statistically significant improvement over the prediction based solely on V3 sequence with 3 percentage points improvement in AUC and 7 percentage points in sensitivity at the specificity of the 11/25 rule (95%). We additionally assessed the predictive power of the new method on clinically derived ‘bulk’ sequence data and obtained a statistically significant improvement in AUC of 3 percentage points over sequence-based prediction. Furthermore, we demonstrated the capacity of our method to predict therapy outcome by applying it to 53 samples from patients undergoing Maraviroc therapy. The analysis of structural features of the loop informative of tropism indicates the importance of two loop regions and their physicochemical properties. The regions are located on opposite strands of the loop stem and the respective features are predominantly charge-, hydrophobicity- and structure-related. These regions are in close proximity in the bound conformation of the loop potentially forming a site determinant for the coreceptor binding. The method is available via server under http://structure.bioinf.mpi-inf.mpg.de/. PMID:23555214
Kumar, Sandeep; Sharma, Deepak; Kumar, Rajesh
2014-03-01
The effect of denaturants on the structural fluctuation of M80-containing Ω-loop of ferrocytochrome c was determined by measuring the rate coefficient of CO-association with ferrocytochrome c under varying concentrations of urea and alkylureas (methylurea (MU), N,N'-dimethylurea (DMU), ethylurea (EU), tetramethylurea (TMU)) at pH7.0, 25°C. As denaturant concentration is increased within the subdenaturing limit, the CO-association reaction is decelerated indicating that subdenaturing concentrations of denaturant reduce the structural fluctuation of the Ω-loop. Structural fluctuation of the Ω-loop is reduced more for urea and least for TMU. Intermolecular docking between horse cytochrome c and denaturant molecule (urea, MU, DMU, EU and TMU) reveals that polyfunctional interactions between the denaturant and different groups of Ω-loop and other part of protein decrease with an increase of alkyl group on urea molecule, which suggests that the decrease in the extent of restricted dynamics of Ω-loop with a corresponding increase of alkyl groups on urea molecule is due to the decrease of denaturant-mediated cross-linking interactions. These denaturant-mediated interactions are expected to reduce the conformational entropy of protein. Analysis of rate-temperature data shows a progressive decrease in conformational entropy of protein in the native to subdenaturing region. Thermodynamic analysis of denaturant (urea, MU, DMU, EU, TMU) effects on the thermal unfolding of ferrocytochrome c reveals that (i) thermodynamic stability of protein decreases with increasing concentration of denaturant or hydrophobicity of urea derivatives, (ii) water activity plays an important role in stabilization of ferrocytochrome c, and (iii) destabilization of ferrocytochrome c by denaturant occurs through the disturbance of hydrophobic interactions and hydrogen-bonding. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Aschwanden, Markus J.; Newmark, Jeff; Delaboudiniere, Jean-Pierre; Neupert, Werner M.; Portier-Fozzani, Fabrice; Gary, G. Allen; Zucker, Arik
1998-01-01
The three-dimensional (3D) structure of solar active region NOAA 7986 observed on 1996 August 30 with the Extrem-ultraviolet Imaging Telescope (EIT) onboard the Solar and Heliospheric Observatory (SoHO) is analyzed. We develop a new method of Dynamic Stereoscopy to reconstruct the 3D geometry of dynamically changing loops, which allows us to determine the orientation of the loop plane with respect to the line-of-sight, a prerequisite to correct properly for projection effects in 3D loop models. With this method and the filter-ratio technique applied to EIT 171 A and 195 A images we determine the 3D coordinates (x(s), y(s), z(s)), the loop width) w(s), the electron density n(sub e)(s), and the electron temperature T(sub e)(s) as function of the loop length s for 30 loop segments. Fitting the loop densities with an exponential density model n(sub e)(h) we find that the so inferred scale height temperatures, T(sub e)(sup lambda) = 1.22 +/- 0.23 MK, match closely the EIT filter-ratio temperatures, T(sub e)(sup FIT) = 1.21 +/- 0.06 MK. We conclude that these rather large-scale loops (with heights of h approx. equals 50 - 200 Mm) that dominate EIT 171 A images are close to thermal equilibrium. Most of the loops show no significant thickness variation w(s), but many exhibit a trend of increasing temperature (dT/ds greater than 0) above the footpoint.
Voice loops as coordination aids in space shuttle mission control.
Patterson, E S; Watts-Perotti, J; Woods, D D
1999-01-01
Voice loops, an auditory groupware technology, are essential coordination support tools for experienced practitioners in domains such as air traffic management, aircraft carrier operations and space shuttle mission control. They support synchronous communication on multiple channels among groups of people who are spatially distributed. In this paper, we suggest reasons for why the voice loop system is a successful medium for supporting coordination in space shuttle mission control based on over 130 hours of direct observation. Voice loops allow practitioners to listen in on relevant communications without disrupting their own activities or the activities of others. In addition, the voice loop system is structured around the mission control organization, and therefore directly supports the demands of the domain. By understanding how voice loops meet the particular demands of the mission control environment, insight can be gained for the design of groupware tools to support cooperative activity in other event-driven domains.
Voice loops as coordination aids in space shuttle mission control
NASA Technical Reports Server (NTRS)
Patterson, E. S.; Watts-Perotti, J.; Woods, D. D.
1999-01-01
Voice loops, an auditory groupware technology, are essential coordination support tools for experienced practitioners in domains such as air traffic management, aircraft carrier operations and space shuttle mission control. They support synchronous communication on multiple channels among groups of people who are spatially distributed. In this paper, we suggest reasons for why the voice loop system is a successful medium for supporting coordination in space shuttle mission control based on over 130 hours of direct observation. Voice loops allow practitioners to listen in on relevant communications without disrupting their own activities or the activities of others. In addition, the voice loop system is structured around the mission control organization, and therefore directly supports the demands of the domain. By understanding how voice loops meet the particular demands of the mission control environment, insight can be gained for the design of groupware tools to support cooperative activity in other event-driven domains.
Detection of no-model input-output pairs in closed-loop systems.
Potts, Alain Segundo; Alvarado, Christiam Segundo Morales; Garcia, Claudio
2017-11-01
The detection of no-model input-output (IO) pairs is important because it can speed up the multivariable system identification process, since all the pairs with null transfer functions are previously discarded and it can also improve the identified model quality, thus improving the performance of model based controllers. In the available literature, the methods focus just on the open-loop case, since in this case there is not the effect of the controller forcing the main diagonal in the transfer matrix to one and all the other terms to zero. In this paper, a modification of a previous method able to detect no-model IO pairs in open-loop systems is presented, but adapted to perform this duty in closed-loop systems. Tests are performed by using the traditional methods and the proposed one to show its effectiveness. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Analysis of flexible aircraft longitudinal dynamics and handling qualities. Volume 2: Data
NASA Technical Reports Server (NTRS)
Waszak, M. R.; Schmidt, D. K.
1985-01-01
Two analysis methods are applied to a family of flexible aircraft in order to investigate how and when structural (especially dynamic aeroelastic) effects affect the dynamic characteristics of aircraft. The first type of analysis is an open loop modal analysis technique. This method considers the effect of modal residue magnitudes on determining vehicle handling qualities. The second method is a pilot in the loop analysis procedure that considers several closed loop system characteristics. Both analyses indicated that dynamic aeroelastic effects caused a degradation in vehicle tracking performance, based on the evaluation of some simulation results. Volume 2 consists of the presentation of the state variable models of the flexible aircraft configurations used in the analysis applications mode shape plots for the structural modes, numerical results from the modal analysis frequency response plots from the pilot in the loop analysis and a listing of the modal analysis computer program.
Cooling method with automated seasonal freeze protection
Cambell, Levi; Chu, Richard; David, Milnes; Ellsworth, Jr, Michael; Iyengar, Madhusudan; Simons, Robert; Singh, Prabjit; Zhang, Jing
2016-05-31
An automated multi-fluid cooling method is provided for cooling an electronic component(s). The method includes obtaining a coolant loop, and providing a coolant tank, multiple valves, and a controller. The coolant loop is at least partially exposed to outdoor ambient air temperature(s) during normal operation, and the coolant tank includes first and second reservoirs containing first and second fluids, respectively. The first fluid freezes at a lower temperature than the second, the second fluid has superior cooling properties compared with the first, and the two fluids are soluble. The multiple valves are controllable to selectively couple the first or second fluid into the coolant in the coolant loop, wherein the coolant includes at least the second fluid. The controller automatically controls the valves to vary first fluid concentration level in the coolant loop based on historical, current, or anticipated outdoor air ambient temperature(s) for a time of year.
Loop optimization for tensor network renormalization
NASA Astrophysics Data System (ADS)
Yang, Shuo; Gu, Zheng-Cheng; Wen, Xiao-Gang
We introduce a tensor renormalization group scheme for coarse-graining a two-dimensional tensor network, which can be successfully applied to both classical and quantum systems on and off criticality. The key idea of our scheme is to deform a 2D tensor network into small loops and then optimize tensors on each loop. In this way we remove short-range entanglement at each iteration step, and significantly improve the accuracy and stability of the renormalization flow. We demonstrate our algorithm in the classical Ising model and a frustrated 2D quantum model. NSF Grant No. DMR-1005541 and NSFC 11274192, BMO Financial Group, John Templeton Foundation, Government of Canada through Industry Canada, Province of Ontario through the Ministry of Economic Development & Innovation.
AGARD (Advisory Group for Aerospace Research & Development) Index of Publications, 1986-1988
1989-08-01
measurements are used in forming the navigation and the baro-inertial loop as well The system communicates with equations to solve for the user position...processing techniques in the tracking ROBERT P. DENARO and G JEFFREY GEIER In AGARD, The loops . and later in the navigation processing ot the Kalman...avionics investigations to predict the dynamic structural response of flexible assessment. The current status of real time, pilot-in-the- loop flight
A parallel-vector algorithm for rapid structural analysis on high-performance computers
NASA Technical Reports Server (NTRS)
Storaasli, Olaf O.; Nguyen, Duc T.; Agarwal, Tarun K.
1990-01-01
A fast, accurate Choleski method for the solution of symmetric systems of linear equations is presented. This direct method is based on a variable-band storage scheme and takes advantage of column heights to reduce the number of operations in the Choleski factorization. The method employs parallel computation in the outermost DO-loop and vector computation via the 'loop unrolling' technique in the innermost DO-loop. The method avoids computations with zeros outside the column heights, and as an option, zeros inside the band. The close relationship between Choleski and Gauss elimination methods is examined. The minor changes required to convert the Choleski code to a Gauss code to solve non-positive-definite symmetric systems of equations are identified. The results for two large-scale structural analyses performed on supercomputers, demonstrate the accuracy and speed of the method.
A parallel-vector algorithm for rapid structural analysis on high-performance computers
NASA Technical Reports Server (NTRS)
Storaasli, Olaf O.; Nguyen, Duc T.; Agarwal, Tarun K.
1990-01-01
A fast, accurate Choleski method for the solution of symmetric systems of linear equations is presented. This direct method is based on a variable-band storage scheme and takes advantage of column heights to reduce the number of operations in the Choleski factorization. The method employs parallel computation in the outermost DO-loop and vector computation via the loop unrolling technique in the innermost DO-loop. The method avoids computations with zeros outside the column heights, and as an option, zeros inside the band. The close relationship between Choleski and Gauss elimination methods is examined. The minor changes required to convert the Choleski code to a Gauss code to solve non-positive-definite symmetric systems of equations are identified. The results for two large scale structural analyses performed on supercomputers, demonstrate the accuracy and speed of the method.
Banded vs Bonded Space Maintainers: Finding Better Way Out.
Setia, Vikas; Kumar Pandit, Inder; Srivastava, Nikhil; Gugnani, Neeraj; Gupta, Monika
2014-05-01
Of this in vivo study was to evaluate various space maintainers in terms of survival rate, gingival health and presence of caries. A total of 60 extraction sites in the age group of 4 to 9 years were divided into four groups and different space maintainers were placed in them viz (conventional band and loop, prefabricated band with custom made loop, Ribbond, Super splint). Prefabricated bands with custom made loop showed maximum success rates (84.6%), while super splint (33.33%) was found to be least successful. In terms of gingival health, prefabricated band with custom made loop reported minimum cases with poor gingival health (27.2%), while maximum cases with poor gingival health (50%) were reported with Super splint. None of the space maintainers developed caries at the end of 9 months. How to cite this article: Setia v, Pandit IK, Srivastava N, Gugnani N, Gupta M. Banded vs Bonded Space Maintainers: Finding Better Way Out. Int J Clin Pediatr Dent 2014;7(2):97-104.
Banded vs Bonded Space Maintainers: Finding Better Way Out
Kumar Pandit, Inder; Srivastava, Nikhil; Gugnani, Neeraj; Gupta, Monika
2014-01-01
ABSTRACT Objectives: Of this in vivo study was to evaluate various space maintainers in terms of survival rate, gingival health and presence of caries. Design: A total of 60 extraction sites in the age group of 4 to 9 years were divided into four groups and different space maintainers were placed in them viz (conventional band and loop, prefabricated band with custom made loop, Ribbond, Super splint). Results: Prefabricated bands with custom made loop showed maximum success rates (84.6%), while super splint (33.33%) was found to be least successful. In terms of gingival health, prefabricated band with custom made loop reported minimum cases with poor gingival health (27.2%), while maximum cases with poor gingival health (50%) were reported with Super splint. None of the space maintainers developed caries at the end of 9 months. How to cite this article: Setia v, Pandit IK, Srivastava N, Gugnani N, Gupta M. Banded vs Bonded Space Maintainers: Finding Better Way Out. Int J Clin Pediatr Dent 2014;7(2):97-104. PMID:25356008
Monteiro, Tiago; Soares, Andreia; Leite, Ricardo Dourado; Franqueira, Nuno; Faria-Correia, Fernando; Vaz, Fernando
2018-01-01
Purpose To evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy. Methods In a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP®) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820®). Results YAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 (p=0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm (p=0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm (p=0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups (p>0.05). Conclusion YAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant. PMID:29593378
Energy Systems Integration News | Energy Systems Integration Facility |
distribution feeder models for use in hardware-in-the-loop (HIL) experiments. Using this method, a full feeder ; proposes an additional control loop to improve frequency support while ensuring stable operation. The and Frequency Deviation," also proposes an additional control loop, this time to smooth the wind
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyko, Konstantin M., E-mail: kmb@inbi.ras.ru; National Research Center “Kurchatov Institute”, Kurchatov Complex of NBICS-technologies, Akad. Kurchatova sqr., 1, Moscow, 123182; Gorbacheva, Marina A.
2016-09-02
Aminoglycoside phosphotransferases represent a broad class of enzymes that promote bacterial resistance to aminoglycoside antibiotics via the phosphorylation of hydroxyl groups in the latter. Here we report the spatial structure of the 3′-aminoglycoside phosphotransferase of novel VIII class (AphVIII) solved by X-ray diffraction method with a resolution of 2.15 Å. Deep analysis of APHVIII structure and its comparison with known structures of aminoglycoside phosphotransferases of various types reveals that AphVIII has a typical two-domain fold and, however, possesses some unique characteristics that distinguish the enzyme from its known homologues. The most important difference is the presence of the activation loop withmore » unique Ser146 residue. We demonstrate that in the apo-state of the enzyme the activation loop does not interact with other parts of the enzyme and seems to adopt catalytically competent state only after substrate binding. - Highlights: • 3D structure of the novel aminoglycoside phosphotransferase AphVIII was obtained. • AphVIII activation loop is clearly identified in the electron density. • AphVIII has some unique structural features in its substrate C-ring binding pocket.« less
NASA Technical Reports Server (NTRS)
Keymeulen, Didier; Ferguson, Michael I.; Fink, Wolfgang; Oks, Boris; Peay, Chris; Terrile, Richard; Cheng, Yen; Kim, Dennis; MacDonald, Eric; Foor, David
2005-01-01
We propose a tuning method for MEMS gyroscopes based on evolutionary computation to efficiently increase the sensitivity of MEMS gyroscopes through tuning. The tuning method was tested for the second generation JPL/Boeing Post-resonator MEMS gyroscope using the measurement of the frequency response of the MEMS device in open-loop operation. We also report on the development of a hardware platform for integrated tuning and closed loop operation of MEMS gyroscopes. The control of this device is implemented through a digital design on a Field Programmable Gate Array (FPGA). The hardware platform easily transitions to an embedded solution that allows for the miniaturization of the system to a single chip.
Robotic guarded motion system and method
Bruemmer, David J.
2010-02-23
A robot platform includes perceptors, locomotors, and a system controller. The system controller executes instructions for repeating, on each iteration through an event timing loop, the acts of defining an event horizon, detecting a range to obstacles around the robot, and testing for an event horizon intrusion. Defining the event horizon includes determining a distance from the robot that is proportional to a current velocity of the robot and testing for the event horizon intrusion includes determining if any range to the obstacles is within the event horizon. Finally, on each iteration through the event timing loop, the method includes reducing the current velocity of the robot in proportion to a loop period of the event timing loop if the event horizon intrusion occurs.
Effect of orientation of prismatic dislocation loops on interaction with free surfaces in BCC iron
NASA Astrophysics Data System (ADS)
Fikar, Jan; Gröger, Roman; Schäublin, Robin
2017-12-01
The prismatic loops appear in metals as a result of high-energy irradiation. Understanding their formation and interaction is important for quantification of irradiation-induced deterioration of mechanical properties. Characterization of dislocation loops in thin foils is commonly made using transmission electron microscopy (TEM), but the results are inevitably influenced by the proximity of free surfaces. The prismatic loops are attracted to free surfaces by image forces. Depending on the type, shape, size, orientation and depth of the loop in the foil, they can escape to the free surface creating denuded loop-free zones and thus invalidating TEM observations. In our previous studies we described a simple general method to determine the critical depth and the critical stress to move prismatic dislocation loops. The critical depths can be further used to correct measurements of the loop density by TEM. Here, we use this procedure to compare 〈100〉 loops and 1/2 〈111〉 loops in body-centered cubic (BCC) iron. The influences of the interatomic potential and the loop orientation are studied in detail. The difference between interstitial and vacancy type loop is also investigated.
The two and three-loop matter bispectrum in perturbation theories
NASA Astrophysics Data System (ADS)
Lazanu, Andrei; Liguori, Michele
2018-04-01
We evaluate for the first time the dark matter bispectrum of large-scale structure at two loops in the Standard Perturbation Theory and at three loops in the Renormalised Perturbation Theory (MPTBREEZE formalism), removing in each case the leading divergences in the integrals in order to make them infrared-safe. We show that the Standard Perturbation Theory at two loops can be employed to model the matter bispectrum further into the quasi-nonlinear regime compared to the one loop, up to kmax ~ 0.1 h/Mpc at z = 0, but without reaching a high level of accuracy. In the case of the MPTBREEZE method, we show that its bispectra decay at smaller and smaller scales with increasing loop order, but with smaller improvements decreases with loop order. At three loops, this model predicts the bispectrum accurately up to scales kmax ~ 0.17 h/Mpc at z = 0 and kmax ~ 0.24 h/Mpc at z = 1.
Operation of a cascade air conditioning system with two-phase loop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Yinshan; Wang, Jinliang; Zhao, Futao
A method of operating a heat transfer system includes starting operation of a first heat transfer fluid vapor/compression circulation loop including a fluid pumping mechanism, a heat exchanger for rejecting thermal energy from a first heat transfer fluid, and a heat absorption side of an internal heat exchanger. A first conduit in a closed fluid circulation loop circulates the first heat transfer fluid therethrough. Operation of a second two-phase heat transfer fluid circulation loop is started after starting operation of the first heat transfer fluid circulation loop. The second heat transfer fluid circulation loop transfers heat to the first heatmore » transfer fluid circulation loop through the internal heat exchanger and includes a heat rejection side of the internal heat exchanger, a liquid pump, and a heat exchanger evaporator. A second conduit in a closed fluid circulation loop circulates a second heat transfer fluid therethrough.« less
Atomistic Simulation of Interstitial Dislocation Loop Evolution under Applied Stresses in BCC Iron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, Xue Hao; Wang, Dong; Setyawan, Wahyu
Evolution of an interstitial 1/2⟨111⟩ dislocation loop under tensile, shear, and torsion stresses is studied with molecular statics method. Under a tensile stress, the dependence of ultimate tensile strength on size of loop is calculated. The formation of small shear loops around the initial prismatic loop is confirmed as an intermediate state to form the final dislocation network. Under a shear stress, the rotation of a loop is observed not only by a change of the habit plane but also through a transformation between a shear and a prismatic loop. Under torsion, a perfect BCC crystal may undergo a BCCmore » to FCC or BCC to HCP transformation. The present work indicates that a 1/2⟨111⟩ loop can delay these transformations, resulting in the formation of micro-crack on the surface.« less
A New Model Based on Adaptation of the External Loop to Compensate the Hysteresis of Tactile Sensors
Sánchez-Durán, José A.; Vidal-Verdú, Fernando; Oballe-Peinado, Óscar; Castellanos-Ramos, Julián; Hidalgo-López, José A.
2015-01-01
This paper presents a novel method to compensate for hysteresis nonlinearities observed in the response of a tactile sensor. The External Loop Adaptation Method (ELAM) performs a piecewise linear mapping of the experimentally measured external curves of the hysteresis loop to obtain all possible internal cycles. The optimal division of the input interval where the curve is approximated is provided by the error minimization algorithm. This process is carried out off line and provides parameters to compute the split point in real time. A different linear transformation is then performed at the left and right of this point and a more precise fitting is achieved. The models obtained with the ELAM method are compared with those obtained from three other approaches. The results show that the ELAM method achieves a more accurate fitting. Moreover, the involved mathematical operations are simpler and therefore easier to implement in devices such as Field Programmable Gate Array (FPGAs) for real time applications. Furthermore, the method needs to identify fewer parameters and requires no previous selection process of operators or functions. Finally, the method can be applied to other sensors or actuators with complex hysteresis loop shapes. PMID:26501279
Stopped-in-loop flow analysis of trace vanadium in water.
Teshima, Norio; Ohno, Shinsuke; Sakai, Tadao
2007-01-01
The new concept of stopped-in-loop flow analysis (SIL-FA) is proposed, and an SIL-FA method for the catalytic determination of vanadium is demonstrated. In an SIL format, a sample solution merges with reagent(s), and the well-mixed solution is loaded into a loop. The solution in the loop is separated by a six-way switching valve from the main stream. While the reaction proceeds in the stationary loop, the SIL-FA system does not need to establish a baseline continuously. This leads to a reduction in reagent consumption and waste generation compared with traditional flow injection analysis.
Posner, Jonathan; Marsh, Rachel; Maia, Tiago V; Peterson, Bradley S; Gruber, Allison; Simpson, H Blair
2014-06-01
Cortico-striato-thalamo-cortical (CSTC) loops project from the cortex to the striatum, then from the striatum to the thalamus via the globus pallidus, and finally from the thalamus back to the cortex again. These loops have been implicated in Obsessive-Compulsive Disorder (OCD) with particular focus on the limbic CSTC loop, which encompasses the orbitofrontal and anterior cingulate cortices, as well as the ventral striatum. Resting state functional-connectivity MRI (rs-fcMRI) studies, which examine temporal correlations in neural activity across brain regions at rest, have examined CSTC loop connectivity in patients with OCD and suggest hyperconnectivity within these loops in medicated adults with OCD. We used rs-fcMRI to examine functional connectivity within CSTC loops in unmedicated adults with OCD (n = 23) versus healthy controls (HCs) (n = 20). Contrary to prior rs-fcMRI studies in OCD patients on medications that report hyperconnectivity in the limbic CSTC loop, we found that compared with HCs, unmedicated OCD participants had reduced connectivity within the limbic CSTC loop. Exploratory analyses revealed that reduced connectivity within the limbic CSTC loop correlated with OCD symptom severity in the OCD group. Our finding of limbic loop hypoconnectivity in unmedicted OCD patients highlights the potential confounding effects of antidepressants on connectivity measures and the value of future examinations of the effects of pharmacological and/or behavioral treatments on limbic CSTC loop connectivity. Copyright © 2013 Wiley Periodicals, Inc.
Three-dimensional geometry of coronal loops inferred by the Principal Component Analysis
NASA Astrophysics Data System (ADS)
Nisticò, Giuseppe; Nakariakov, Valery
We propose a new method for the determination of the three dimensional (3D) shape of coronal loops from stereoscopy. The common approach requires to find a 1D geometric curve, as circumference or ellipse, that best-fits the 3D tie-points which sample the loop shape in a given coordinate system. This can be easily achieved by the Principal Component (PC) analysis. It mainly consists in calculating the eigenvalues and eigenvectors of the covariance matrix of the 3D tie-points: the eigenvalues give a measure of the variability of the distribution of the tie-points, and the corresponding eigenvectors define a new cartesian reference frame directly related to the loop. The eigenvector associated with the smallest eigenvalues defines the normal to the loop plane, while the other two determine the directions of the loop axes: the major axis is related to the largest eigenvalue, and the minor axis with the second one. The magnitude of the axes is directly proportional to the square roots of these eigenvalues. The technique is fast and easily implemented in some examples, returning best-fitting estimations of the loop parameters and 3D reconstruction with a reasonable small number of tie-points. The method is suitable for serial reconstruction of coronal loops in active regions, providing a useful tool for comparison between observations and theoretical magnetic field extrapolations from potential or force-free fields.
Single-scale renormalisation group improvement of multi-scale effective potentials
NASA Astrophysics Data System (ADS)
Chataignier, Leonardo; Prokopec, Tomislav; Schmidt, Michael G.; Świeżewska, Bogumiła
2018-03-01
We present a new method for renormalisation group improvement of the effective potential of a quantum field theory with an arbitrary number of scalar fields. The method amounts to solving the renormalisation group equation for the effective potential with the boundary conditions chosen on the hypersurface where quantum corrections vanish. This hypersurface is defined through a suitable choice of a field-dependent value for the renormalisation scale. The method can be applied to any order in perturbation theory and it is a generalisation of the standard procedure valid for the one-field case. In our method, however, the choice of the renormalisation scale does not eliminate individual logarithmic terms but rather the entire loop corrections to the effective potential. It allows us to evaluate the improved effective potential for arbitrary values of the scalar fields using the tree-level potential with running coupling constants as long as they remain perturbative. This opens the possibility of studying various applications which require an analysis of multi-field effective potentials across different energy scales. In particular, the issue of stability of the scalar potential can be easily studied beyond tree level.
Phase structure of the Polyakov-quark-meson model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schaefer, B.-J.; Pawlowski, J. M.; Wambach, J.
2007-10-01
The relation between the deconfinement and chiral phase transition is explored in the framework of a Polyakov-loop-extended two-flavor quark-meson (PQM) model. In this model the Polyakov loop dynamics is represented by a background temporal gauge field which also couples to the quarks. As a novelty an explicit quark chemical potential and N{sub f}-dependence in the Polyakov loop potential is proposed by using renormalization group arguments. The behavior of the Polyakov loop as well as the chiral condensate as function of temperature and quark chemical potential is obtained by minimizing the grand canonical thermodynamic potential of the system. The effect ofmore » the Polyakov loop dynamics on the chiral phase diagram and on several thermodynamic bulk quantities is presented.« less
Steed, P Ryan; Kraft, Kaitlin A; Fillingame, Robert H
2014-11-25
H(+)-transporting F1F0 ATP synthase catalyzes the synthesis of ATP via coupled rotary motors within F0 and F1. H(+) transport at the subunit a-c interface in transmembranous F0 drives rotation of a cylindrical c10 oligomer within the membrane, which is coupled to rotation of subunit γ within the α3β3 sector of F1 to mechanically drive ATP synthesis. F1F0 functions in a reversible manner, with ATP hydrolysis driving H(+) transport. ATP-driven H(+) transport in a select group of cysteine mutants in subunits a and c is inhibited after chelation of Ag(+) and/or Cd(+2) with the substituted sulfhydryl groups. The H(+) transport pathway mapped via these Ag(+)(Cd(+2))-sensitive Cys extends from the transmembrane helices (TMHs) of subunits a and c into cytoplasmic loops connecting the TMHs, suggesting these loop regions could be involved in gating H(+) release to the cytoplasm. Here, using select loop-region Cys from the single cytoplasmic loop of subunit c and multiple cytoplasmic loops of subunit a, we show that Cd(+2) directly inhibits passive H(+) transport mediated by F0 reconstituted in liposomes. Further, in extensions of previous studies, we show that the regions mediating passive H(+) transport can be cross-linked to each other. We conclude that the loop-regions in subunits a and c that are implicated in H(+) transport likely interact in a single structural domain, which then functions in gating H(+) release to the cytoplasm.
Vehicle Classification Using the Discrete Fourier Transform with Traffic Inductive Sensors.
Lamas-Seco, José J; Castro, Paula M; Dapena, Adriana; Vazquez-Araujo, Francisco J
2015-10-26
Inductive Loop Detectors (ILDs) are the most commonly used sensors in traffic management systems. This paper shows that some spectral features extracted from the Fourier Transform (FT) of inductive signatures do not depend on the vehicle speed. Such a property is used to propose a novel method for vehicle classification based on only one signature acquired from a sensor single-loop, in contrast to standard methods using two sensor loops. Our proposal will be evaluated by means of real inductive signatures captured with our hardware prototype.
Excitation of vertical coronal loop oscillations by impulsively driven flows
NASA Astrophysics Data System (ADS)
Kohutova, P.; Verwichte, E.
2018-05-01
Context. Flows of plasma along a coronal loop caused by the pressure difference between loop footpoints are common in the solar corona. Aims: We aim to investigate the possibility of excitation of loop oscillations by an impulsively driven flow triggered by an enhanced pressure in one of the loop footpoints. Methods: We carry out 2.5D magnetohydrodynamic (MHD) simulations of a coronal loop with an impulsively driven flow and investigate the properties and evolution of the resulting oscillatory motion of the loop. Results: The action of the centrifugal force associated with plasma moving at high speeds along the curved axis of the loop is found to excite the fundamental harmonic of a vertically polarised kink mode. We analyse the dependence of the resulting oscillations on the speed and kinetic energy of the flow. Conclusions: We find that flows with realistic speeds of less than 100 km s-1 are sufficient to excite oscillations with observable amplitudes. We therefore propose plasma flows as a possible excitation mechanism for observed transverse loop oscillations.
Methods and apparatus for broadband frequency comb stabilization
Cox, Jonathan A; Kaertner, Franz X
2015-03-17
Feedback loops can be used to shift and stabilize the carrier-envelope phase of a frequency comb from a mode-locked fibers laser or other optical source. Compared to other frequency shifting and stabilization techniques, feedback-based techniques provide a wideband closed-loop servo bandwidth without optical filtering, beam pointing errors, or group velocity dispersion. It also enables phase locking to a stable reference, such as a Ti:Sapphire laser, continuous-wave microwave or optical source, or self-referencing interferometer, e.g., to within 200 mrad rms from DC to 5 MHz. In addition, stabilized frequency combs can be coherently combined with other stable signals, including other stabilized frequency combs, to synthesize optical pulse trains with pulse durations of as little as a single optical cycle. Such a coherent combination can be achieved via orthogonal control, using balanced optical cross-correlation for timing stabilization and balanced homodyne detection for phase stabilization.
Control Law Synthesis for Vertical Fin Buffeting Alleviation Using Strain Actuation
NASA Technical Reports Server (NTRS)
Nitzsche, F.; Zimcik, D. G.; Ryall, T. G.; Moses, R. W.; Henderson, D. A.
1999-01-01
In the present investigation, the results obtained during the ground test of a closed-loop control system conducted on a full-scale fighter to attenuate vertical fin buffeting response using strain actuation are presented. Two groups of actuators consisting of piezoelectric elements distributed over the structure were designed to achieve authority over the first and second modes of the vertical fin. The control laws were synthesized using the Linear Quadratic Gaussian (LQG) method for a time-invariant control system. Three different pairs of sensors including strain gauges and accelerometers at different locations were used to close the feedback loop. The results demonstrated that measurable reductions in the root-mean-square (RMS) values of the fin dynamic response identified by the strain transducer at the critical point for fatigue at the root were achieved under the most severe buffet condition. For less severe buffet conditions, reductions of up to 58% were achieved.
Gonthier, Gerard
2007-01-01
A graphical method that uses continuous water-level and barometric-pressure data was developed to estimate barometric efficiency. A plot of nearly continuous water level (on the y-axis), as a function of nearly continuous barometric pressure (on the x-axis), will plot as a line curved into a series of connected elliptical loops. Each loop represents a barometric-pressure fluctuation. The negative of the slope of the major axis of an elliptical loop will be the ratio of water-level change to barometric-pressure change, which is the sum of the barometric efficiency plus the error. The negative of the slope of the preferred orientation of many elliptical loops is an estimate of the barometric efficiency. The slope of the preferred orientation of many elliptical loops is approximately the median of the slopes of the major axes of the elliptical loops. If water-level change that is not caused by barometric-pressure change does not correlate with barometric-pressure change, the probability that the error will be greater than zero will be the same as the probability that it will be less than zero. As a result, the negative of the median of the slopes for many loops will be close to the barometric efficiency. The graphical method provided a rapid assessment of whether a well was affected by barometric-pressure change and also provided a rapid estimate of barometric efficiency. The graphical method was used to assess which wells at Air Force Plant 6, Marietta, Georgia, had water levels affected by barometric-pressure changes during a 2003 constant-discharge aquifer test. The graphical method was also used to estimate barometric efficiency. Barometric-efficiency estimates from the graphical method were compared to those of four other methods: average of ratios, median of ratios, Clark, and slope. The two methods (the graphical and median-of-ratios methods) that used the median values of water-level change divided by barometric-pressure change appeared to be most resistant to error caused by barometric-pressure-independent water-level change. The graphical method was particularly resistant to large amounts of barometric-pressure-independent water-level change, having an average and standard deviation of error for control wells that was less than one-quarter that of the other four methods. When using the graphical method, it is advisable that more than one person select the slope or that the same person fits the same data several times to minimize the effect of subjectivity. Also, a long study period should be used (at least 60 days) to ensure that loops affected by large amounts of barometric-pressure-independent water-level change do not significantly contribute to error in the barometric-efficiency estimate.
Ly, Trang T; Roy, Anirban; Grosman, Benyamin; Shin, John; Campbell, Alex; Monirabbasi, Salman; Liang, Bradley; von Eyben, Rie; Shanmugham, Satya; Clinton, Paula; Buckingham, Bruce A
2015-07-01
To evaluate the feasibility and efficacy of a fully integrated hybrid closed-loop (HCL) system (Medtronic MiniMed Inc., Northridge, CA), in day and night closed-loop control in subjects with type 1 diabetes, both in an inpatient setting and during 6 days at diabetes camp. The Medtronic MiniMed HCL system consists of a fourth generation (4S) glucose sensor, a sensor transmitter, and an insulin pump using a modified proportional-integral-derivative (PID) insulin feedback algorithm with safety constraints. Eight subjects were studied over 48 h in an inpatient setting. This was followed by a study of 21 subjects for 6 days at diabetes camp, randomized to either the closed-loop control group using the HCL system or to the group using the Medtronic MiniMed 530G with threshold suspend (control group). The overall mean sensor glucose percent time in range 70-180 mg/dL was similar between the groups (73.1% vs. 69.9%, control vs. HCL, respectively) (P = 0.580). Meter glucose values between 70 and 180 mg/dL were also similar between the groups (73.6% vs. 63.2%, control vs. HCL, respectively) (P = 0.086). The mean absolute relative difference of the 4S sensor was 10.8 ± 10.2%, when compared with plasma glucose values in the inpatient setting, and 12.6 ± 11.0% compared with capillary Bayer CONTOUR NEXT LINK glucose meter values during 6 days at camp. In the first clinical study of this fully integrated system using an investigational PID algorithm, the system did not demonstrate improved glucose control compared with sensor-augmented pump therapy alone. The system demonstrated good connectivity and improved sensor performance. © 2015 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.
Chern-Simons expectation values and quantum horizons from loop quantum gravity and the Duflo map.
Sahlmann, Hanno; Thiemann, Thomas
2012-03-16
We report on a new approach to the calculation of Chern-Simons theory expectation values, using the mathematical underpinnings of loop quantum gravity, as well as the Duflo map, a quantization map for functions on Lie algebras. These new developments can be used in the quantum theory for certain types of black hole horizons, and they may offer new insights for loop quantum gravity, Chern-Simons theory and the theory of quantum groups.
Coronal loop seismology using damping of standing kink oscillations by mode coupling
NASA Astrophysics Data System (ADS)
Pascoe, D. J.; Goddard, C. R.; Nisticò, G.; Anfinogentov, S.; Nakariakov, V. M.
2016-05-01
Context. Kink oscillations of solar coronal loops are frequently observed to be strongly damped. The damping can be explained by mode coupling on the condition that loops have a finite inhomogeneous layer between the higher density core and lower density background. The damping rate depends on the loop density contrast ratio and inhomogeneous layer width. Aims: The theoretical description for mode coupling of kink waves has been extended to include the initial Gaussian damping regime in addition to the exponential asymptotic state. Observation of these damping regimes would provide information about the structuring of the coronal loop and so provide a seismological tool. Methods: We consider three examples of standing kink oscillations observed by the Atmospheric Imaging Assembly (AIA) of the Solar Dynamics Observatory (SDO) for which the general damping profile (Gaussian and exponential regimes) can be fitted. Determining the Gaussian and exponential damping times allows us to perform seismological inversions for the loop density contrast ratio and the inhomogeneous layer width normalised to the loop radius. The layer width and loop minor radius are found separately by comparing the observed loop intensity profile with forward modelling based on our seismological results. Results: The seismological method which allows the density contrast ratio and inhomogeneous layer width to be simultaneously determined from the kink mode damping profile has been applied to observational data for the first time. This allows the internal and external Alfvén speeds to be calculated, and estimates for the magnetic field strength can be dramatically improved using the given plasma density. Conclusions: The kink mode damping rate can be used as a powerful diagnostic tool to determine the coronal loop density profile. This information can be used for further calculations such as the magnetic field strength or phase mixing rate.
Rockx, Marie Antoinette; Hoch, Jeffrey S; Klein, George J; Yee, Raymond; Skanes, Allan C; Gula, Lorne J; Krahn, Andrew D
2005-11-01
Out patient ambulatory monitoring is often performed in patients with syncope that present in the primary care setting to include or exclude an arrhythmia. The cost-effectiveness of 2 monitoring strategies was assessed in a prospective randomized trial. One hundred patients referred for ambulatory monitoring with syncope or presyncope were randomized to a 1-month external loop recorder (n = 49) or 48-hour Holter monitor (n = 51). Patients were offered crossover if there was failed activation or no symptom recurrence. The primary end point was symptom-rhythm correlation during monitoring. Direct costs were calculated based on the 2003 Ontario Health Insurance Plan fee schedule, combined with calculation of labor, materials, service, and overhead for diagnostic testing and related equipment. Before enrollment, the cost of all previous health care resource use was USD 472 +/- USD 397 (range USD 21-USD 1965). In the loop recorder group, 63% of patients had symptom recurrence and successful activation, compared with 24% in the Holter group (P < .0001). The cost per Holter was USD 177.64, and per loop recorder, USD 533.56, with a similar cost per diagnosis with the 2 techniques. The incremental cost-effectiveness ratio of the loop recorder was USD 901.74 per extra successful diagnosis. A strategy of Holter followed by offered loop recorder trended toward lower cost than initial loop recorder followed by Holter (USD 481 +/- USD 267 vs USD 551 +/- USD 83, P = .08), but was associated with a lower overall diagnostic yield (49% vs 63%) and a resultant higher cost per diagnosis (USD 982 vs USD 871, P = .08). Bootstrapping suggested that 90% of incremental cost-effectiveness ratios were less than USD 1250. Despite the increased upfront cost of external loop recorders, the marked improvement in diagnostic yield offsets the cost. External loop recorders are an economically attractive alternative. First-line use of external loop recorders in patients with "community-acquired" syncope and presyncope should be considered to optimize diagnostic yield given its value.
Closed loop problems in biomechanics. Part II--an optimization approach.
Vaughan, C L; Hay, J G; Andrews, J G
1982-01-01
A closed loop problem in biomechanics may be defined as a problem in which there are one or more closed loops formed by the human body in contact with itself or with an external system. Under certain conditions the problem is indeterminate--the unknown forces and torques outnumber the equations. Force transducing devices, which would help solve this problem, have serious drawbacks, and existing methods are inaccurate and non-general. The purposes of the present paper are (1) to develop a general procedure for solving closed loop problems; (2) to illustrate the application of the procedure; and (3) to examine the validity of the procedure. A mathematical optimization approach is applied to the solution of three different closed loop problems--walking up stairs, vertical jumping and cartwheeling. The following conclusions are drawn: (1) the method described is reasonably successful for predicting horizontal and vertical reaction forces at the distal segments although problems exist for predicting the points of application of these forces; (2) the results provide some support for the notion that the human neuromuscular mechanism attempts to minimize the joint torques and thus, to a certain degree, the amount of muscular effort; (3) in the validation procedure it is desirable to have a force device for each of the distal segments in contact with a fixed external system; and (4) the method is sufficiently general to be applied to all classes of closed loop problems.
Matsukuma, Shoichi; Yoshihara, Mitsuyo; Kasai, Fumio; Kato, Akinori; Yoshida, Akira; Akaike, Makoto; Kobayashi, Osamu; Nakayama, Haruhiko; Sakuma, Yuji; Yoshida, Tsutomu; Kameda, Yoichi; Tsuchiya, Eiju; Miyagi, Yohei
2006-01-01
A simple and rapid method to detect the epidermal growth factor receptor hot spot mutation L858R in lung adenocarcinoma was developed based on principles similar to the universal heteroduplex generator technology. A single-stranded oligonucleotide with an internal deletion was used to generate heteroduplexes (loop-hybrids) bearing a loop in the complementary strand derived from the polymerase chain reaction product of the normal or mutant allele. By placing deletion in the oligonucleotide adjacent to the mutational site, difference in electrophoretic mobility between loop-hybrids with normal and mutated DNA was distinguishable in a native polyacrylamide gel. The method was also modified to detect in-frame deletion mutations of epidermal growth factor receptor in lung adenocarcinomas. In addition, the method was adapted to detect hot spot mutations in the B-type Raf kinase (BRAF) at V600 and in a Ras-oncogene (NRAS) at Q61, the mutations commonly found in thyroid carcinomas. Our mutation detection system, designated the loop-hybrid mobility shift assay was sensitive enough to detect mutant DNA comprising 7.5% of the total DNA. As a simple and straightforward mutation detection technique, loop-hybrid mobility shift assay may be useful for the molecular diagnosis of certain types of clinical cancers. Other applications are also discussed. PMID:16931592
Eteng, Akaa Agbaeze; Abdul Rahim, Sharul Kamal; Leow, Chee Yen; Chew, Beng Wah; Vandenbosch, Guy A E
2016-01-01
Q-factor constraints are usually imposed on conductor loops employed as proximity range High Frequency Radio Frequency Identification (HF-RFID) reader antennas to ensure adequate data bandwidth. However, pairing such low Q-factor loops in inductive energy transmission links restricts the link transmission performance. The contribution of this paper is to assess the improvement that is reached with a two-stage design method, concerning the transmission performance of a planar square loop relative to an initial design, without compromise to a Q-factor constraint. The first stage of the synthesis flow is analytical in approach, and determines the number and spacing of turns by which coupling between similar paired square loops can be enhanced with low deviation from the Q-factor limit presented by an initial design. The second stage applies full-wave electromagnetic simulations to determine more appropriate turn spacing and widths to match the Q-factor constraint, and achieve improved coupling relative to the initial design. Evaluating the design method in a test scenario yielded a more than 5% increase in link transmission efficiency, as well as an improvement in the link fractional bandwidth by more than 3%, without violating the loop Q-factor limit. These transmission performance enhancements are indicative of a potential for modifying proximity HF-RFID reader antennas for efficient inductive energy transfer and data telemetry links.
Multi-loop control of UPS inverter with a plug-in odd-harmonic repetitive controller.
Razi, Reza; Karbasforooshan, Mohammad-Sadegh; Monfared, Mohammad
2017-03-01
This paper proposes an improved multi-loop control scheme for the single-phase uninterruptible power supply (UPS) inverter by using a plug-in odd-harmonic repetitive controller to regulate the output voltage. In the suggested control method, the output voltage and the filter capacitor current are used as the outer and inner loop feedback signals, respectively and the instantaneous value of the reference voltage feedforwarded to the output of the controller. Instead of conventional linear (proportional-integral/-resonant) and conventional repetitive controllers, a plug-in odd-harmonic repetitive controller is employed in the outer loop to regulate the output voltage, which occupies less memory space and offers faster tracking performance compared to the conventional one. Also, a simple proportional controller is used in the inner loop for active damping of possible resonances and improving the transient performance. The feedforward of the converter reference voltage enhances the robust performance of the system and simplifies the system modelling and the controller design. A step-by-step design procedure is presented for the proposed controller, which guarantees stability of the system under worst-case scenarios. Simulation and experimental results validate the excellent steady-state and transient performance of the proposed control scheme and provide the exact comparison of the proposed method with the conventional multi-loop control method. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Study of the post-flare loops on 29 July 1973. II - Physical parameters in the X-ray loops
NASA Technical Reports Server (NTRS)
Petrasso, R. D.; Nolte, J. T.; Gerassimenko, M.; Krieger, A. S.; Krogstad, R.; Seguin, F. H.; Svestka, Z.
1979-01-01
We use the filter ratio method of analysis to determine spatially resolved values of plasma parameters in the X-ray emitting post-flare loop system which developed on 29 and 30 July 1973. We find that the loops were hotter and had higher plasma pressure at their tops than near their footpoints. The loop tops were at nearly the same temperature at different places 3 hr after the flare maximum and were also at nearly this same temperature 3 and 8 hr later. Variations in brightness transverse to the loops were due to variations in emission measure. We show by consideration of radiative losses alone that energy must have been added to the hottest part of the flare, at the tops of the loops, late in the decay phase of the flare.
Iterative LQG Controller Design Through Closed-Loop Identification
NASA Technical Reports Server (NTRS)
Hsiao, Min-Hung; Huang, Jen-Kuang; Cox, David E.
1996-01-01
This paper presents an iterative Linear Quadratic Gaussian (LQG) controller design approach for a linear stochastic system with an uncertain open-loop model and unknown noise statistics. This approach consists of closed-loop identification and controller redesign cycles. In each cycle, the closed-loop identification method is used to identify an open-loop model and a steady-state Kalman filter gain from closed-loop input/output test data obtained by using a feedback LQG controller designed from the previous cycle. Then the identified open-loop model is used to redesign the state feedback. The state feedback and the identified Kalman filter gain are used to form an updated LQC controller for the next cycle. This iterative process continues until the updated controller converges. The proposed controller design is demonstrated by numerical simulations and experiments on a highly unstable large-gap magnetic suspension system.
Complete one-loop renormalization of the Higgs-electroweak chiral Lagrangian
NASA Astrophysics Data System (ADS)
Buchalla, G.; Catà, O.; Celis, A.; Knecht, M.; Krause, C.
2018-03-01
Employing background-field method and super-heat-kernel expansion, we compute the complete one-loop renormalization of the electroweak chiral Lagrangian with a light Higgs boson. Earlier results from purely scalar fluctuations are confirmed as a special case. We also recover the one-loop renormalization of the conventional Standard Model in the appropriate limit.
2011-01-01
Background Colorectal cancer is the second most common tumor in developed countries, with a lifetime prevalence of 5%. About one third of these tumors are located in the rectum. Surgery in terms of low anterior resection with mesorectal excision is the central element in the treatment of rectal cancer being the only option for definite cure. Creating a protective diverting stoma prevents complications like anastomotic failure and meanwhile is the standard procedure. Bowel obstruction is one of the main and the clinically and economically most relevant complication following closure of loop ileostomy. The best surgical technique for closure of loop ileostomy has not been defined yet. Methods/Design A study protocol was developed on the basis of the only randomized controlled mono-center trial to solve clinical equipoise concerning the optimal surgical technique for closure of loop ileostomy after low anterior resection due to rectal cancer. The HASTA trial is a multi-center pragmatic randomized controlled surgical trial with two parallel groups to compare hand-suture versus stapling for closure of loop ileostomy. It will include 334 randomized patients undergoing closure of loop ileostomy after low anterior resection with protective ileostomy due to rectal cancer in approximately 20 centers consisting of German hospitals of all level of health care. The primary endpoint is the rate of bowel obstruction within 30 days after ileostomy closure. In addition, a set of surgical and general variables including quality of life will be analyzed with a follow-up of 12 months. An investigators meeting with a practical session will help to minimize performance bias and enforce protocol adherence. Centers are monitored centrally as well as on-site before and during recruitment phase to assure inclusion, treatment and follow up according to the protocol. Discussion Aim of the HASTA trial is to evaluate the efficacy of hand-suture versus stapling for closure of loop ileostomy in patients with rectal cancer. Trial registration German Clinical Trial Register Number: DRKS00000040 PMID:21303515
Use of an open-loop system to increase physical activity
USDA-ARS?s Scientific Manuscript database
This study evaluated the effectiveness of an open-loop system that reinforces physical activity with TV watching to increase children’s physical activity. Non-overweight, sedentary boys and girls (8-12 y) were randomized to a group that received feedback of activity counts + reinforcement for physic...
Control and optimization system and method for chemical looping processes
Lou, Xinsheng; Joshi, Abhinaya; Lei, Hao
2014-06-24
A control system for optimizing a chemical loop system includes one or more sensors for measuring one or more parameters in a chemical loop. The sensors are disposed on or in a conduit positioned in the chemical loop. The sensors generate one or more data signals representative of an amount of solids in the conduit. The control system includes a data acquisition system in communication with the sensors and a controller in communication with the data acquisition system. The data acquisition system receives the data signals and the controller generates the control signals. The controller is in communication with one or more valves positioned in the chemical loop. The valves are configured to regulate a flow of the solids through the chemical loop.
Control and optimization system and method for chemical looping processes
Lou, Xinsheng; Joshi, Abhinaya; Lei, Hao
2015-02-17
A control system for optimizing a chemical loop system includes one or more sensors for measuring one or more parameters in a chemical loop. The sensors are disposed on or in a conduit positioned in the chemical loop. The sensors generate one or more data signals representative of an amount of solids in the conduit. The control system includes a data acquisition system in communication with the sensors and a controller in communication with the data acquisition system. The data acquisition system receives the data signals and the controller generates the control signals. The controller is in communication with one or more valves positioned in the chemical loop. The valves are configured to regulate a flow of the solids through the chemical loop.
Applying systems theory to the evaluation of a whole school approach to violence prevention.
Kearney, Sarah; Leung, Loksee; Joyce, Andrew; Ollis, Debbie; Green, Celia
2016-02-01
Issue addressed Our Watch led a complex 12-month evaluation of a whole school approach to Respectful Relationships Education (RRE) implemented in 19 schools. RRE is an emerging field aimed at preventing gender-based violence. This paper will illustrate how from an implementation science perspective, the evaluation was a critical element in the change process at both a school and policy level. Methods Using several conceptual approaches from systems science, the evaluation sought to examine how the multiple systems layers - student, teacher, school, community and government - interacted and influenced each other. A distinguishing feature of the evaluation included 'feedback loops'; that is, evaluation data was provided to participants as it became available. Evaluation tools included a combination of standardised surveys (with pre- and post-intervention data provided to schools via individualised reports), reflection tools, regular reflection interviews and summative focus groups. Results Data was shared during implementation with project staff, department staff and schools to support continuous improvement at these multiple systems levels. In complex settings, implementation can vary according to context; and the impact of evaluation processes, tools and findings differed across the schools. Interviews and focus groups conducted at the end of the project illustrated which of these methods were instrumental in motivating change and engaging stakeholders at both a school and departmental level and why. Conclusion The evaluation methods were a critical component of the pilot's approach, helping to shape implementation through data feedback loops and reflective practice for ongoing, responsive and continuous improvement. Future health promotion research on complex interventions needs to examine how the evaluation itself is influencing implementation. So what? The pilot has demonstrated that the evaluation, including feedback loops to inform project activity, were an asset to implementation. This has implications for other health promotion activities, where evaluation tools could be utilised to enhance, rather than simply measure, an intervention. The findings are relevant to a range of health promotion research activities because they demonstrate the importance of meta-evaluation techniques that seek to understand how the evaluation itself was influencing implementation and outcomes.
Chellali, A.; Ahn, W.; Sankaranarayanan, G.; Flinn, J. T.; Schwaitzberg, S. D.; Jones, D.B.; De, Suvranu; Cao, C.G.L.
2014-01-01
Introduction The Fundamentals of Laparoscopic Surgery (FLS) trainer is currently the standard for training and evaluating basic laparoscopic skills. However, its manual scoring system is time-consuming and subjective. The Virtual Basic Laparoscopic Skill Trainer (VBLaST©) is the virtual version of the FLS trainer which allows automatic and real time assessment of skill performance, as well as force feedback. In this study, the VBLaST© pattern cutting (VBLaST-PC©) and ligating loop (VBLaST-LL©) tasks were evaluated as part of a validation study. We hypothesized that performance would be similar on the FLS and VBLaST© trainers, and that subjects with more experience would perform better than those with less experience on both trainers. Methods Fifty-five subjects with varying surgical experience were recruited at the Learning Center during the 2013 SAGES annual meeting and were divided into two groups: experts (PGY 5, surgical fellows and surgical attendings) and novices (PGY 1–4). They were asked to perform the pattern cutting or the ligating loop task on the FLS and the VBLaST© trainers. Their performance scores for each trainer were calculated and compared. Results There were no significant differences between the FLS and VBLaST© scores for either the pattern cutting or the ligating loop task. Experts’ scores were significantly higher than the scores for novices on both trainers. Conclusion This study showed that the subjects’ performance on the VBLaST© trainer was similar to the FLS performance for both tasks. Both the VBLaST-PC© and the VBLaST-LL© tasks permitted discrimination between the novice and expert groups. Though concurrent and discriminant validity has been established, further studies to establish convergent and predictive validity are needed. Once validated as a training system for laparoscopic skills, the system is expected to overcome the current limitations of the FLS trainer. PMID:25159626
One-loop matching and running with covariant derivative expansion
Henning, Brian; Lu, Xiaochuan; Murayama, Hitoshi
2018-01-24
We develop tools for performing effective field theory (EFT) calculations in a manifestly gauge-covariant fashion. We clarify how functional methods account for one-loop diagrams resulting from the exchange of both heavy and light fields, as some confusion has recently arisen in the literature. To efficiently evaluate functional traces containing these “mixed” one-loop terms, we develop a new covariant derivative expansion (CDE) technique that is capable of evaluating a much wider class of traces than previous methods. The technique is detailed in an appendix, so that it can be read independently from the rest of this work. We review the well-knownmore » matching procedure to one-loop order with functional methods. What we add to this story is showing how to isolate one-loop terms coming from diagrams involving only heavy propagators from diagrams with mixed heavy and light propagators. This is done using a non-local effective action, which physically connects to the notion of “integrating out” heavy fields. Lastly, we show how to use a CDE to do running analyses in EFTs, i.e. to obtain the anomalous dimension matrix. We demonstrate the methodologies by several explicit example calculations.« less
One-loop matching and running with covariant derivative expansion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henning, Brian; Lu, Xiaochuan; Murayama, Hitoshi
We develop tools for performing effective field theory (EFT) calculations in a manifestly gauge-covariant fashion. We clarify how functional methods account for one-loop diagrams resulting from the exchange of both heavy and light fields, as some confusion has recently arisen in the literature. To efficiently evaluate functional traces containing these “mixed” one-loop terms, we develop a new covariant derivative expansion (CDE) technique that is capable of evaluating a much wider class of traces than previous methods. The technique is detailed in an appendix, so that it can be read independently from the rest of this work. We review the well-knownmore » matching procedure to one-loop order with functional methods. What we add to this story is showing how to isolate one-loop terms coming from diagrams involving only heavy propagators from diagrams with mixed heavy and light propagators. This is done using a non-local effective action, which physically connects to the notion of “integrating out” heavy fields. Lastly, we show how to use a CDE to do running analyses in EFTs, i.e. to obtain the anomalous dimension matrix. We demonstrate the methodologies by several explicit example calculations.« less
One-loop matching and running with covariant derivative expansion
NASA Astrophysics Data System (ADS)
Henning, Brian; Lu, Xiaochuan; Murayama, Hitoshi
2018-01-01
We develop tools for performing effective field theory (EFT) calculations in a manifestly gauge-covariant fashion. We clarify how functional methods account for one-loop diagrams resulting from the exchange of both heavy and light fields, as some confusion has recently arisen in the literature. To efficiently evaluate functional traces containing these "mixed" one-loop terms, we develop a new covariant derivative expansion (CDE) technique that is capable of evaluating a much wider class of traces than previous methods. The technique is detailed in an appendix, so that it can be read independently from the rest of this work. We review the well-known matching procedure to one-loop order with functional methods. What we add to this story is showing how to isolate one-loop terms coming from diagrams involving only heavy propagators from diagrams with mixed heavy and light propagators. This is done using a non-local effective action, which physically connects to the notion of "integrating out" heavy fields. Lastly, we show how to use a CDE to do running analyses in EFTs, i.e. to obtain the anomalous dimension matrix. We demonstrate the methodologies by several explicit example calculations.
NASA Astrophysics Data System (ADS)
Cao, Huiliang; Li, Hongsheng; Shao, Xingling; Liu, Zhiyu; Kou, Zhiwei; Shan, Yanhu; Shi, Yunbo; Shen, Chong; Liu, Jun
2018-01-01
This paper presents the bandwidth expanding method with wide-temperature range for sense mode coupling dual-mass MEMS gyro. The real sensing mode of the gyroscope is analyzed to be the superposition of in-phase and anti-phase sensing modes. The mechanical sensitivity and bandwidth of the gyroscope structure are conflicted with each other and both governed by the frequency difference between sensing and drive modes (min {Δω1, Δω2}). The sensing mode force rebalancing combs stimulation method (FRCSM) is presented to simulate the Coriolis force, and based on this method, the gyro's dynamic characteristics are tested. The sensing closed- loop controller is achieved by operational amplifier based on phase lead method, which enable the magnitude margin and phase margin of the system to reach 7.21 dB and 34.6° respectively, and the closed-loop system also expands gyro bandwidth from 13 Hz (sensing open-loop) to 102 Hz (sensing closed-loop). What's more, the turntable test results show that the sensing closed-loop works stably in wide-temperature range (from -40 °C to 60 °C) and the bandwidth values are 107 Hz @-40 °C and 97 Hz @60 °C. The results indicate that the higher temperature causes lower bandwidth, and verify the simulation results are 103 Hz @-40 °C and 98.2 Hz @60 °C. The new bottleneck of the closed loop bandwidth is the valley generated by conjugate zeros, which is formed by superposition of sensing modes.
Zhang, Wenpeng; Zhang, Zixin; Meng, Jiawei; Zhou, Wei; Chen, Zilin
2014-10-24
In this work, we interestingly happened to observe the adsorption of stainless steel sample loop of HPLC. The adsorptive behaviors of the stainless steel loop toward different kinds of compounds were studied, including polycyclic aromatic hydrocarbons (PAHs), halogeno benzenes, aniline derivatives, benzoic acid derivatives, phenols, benzoic acid ethyl ester, benzaldehyde, 1-phenyl-ethanone and phenethyl alcohol. The adsorptive mechanism was probably related to hydrophobic interaction, electron-rich element-metal interaction and hydrogen bond. Universal adsorption of stainless steels was also testified. Inspired by its strong adsorptive capability, bare stainless steel loop was developed as a modification-free in-tube device for solid-phase microextraction (SPME), which served as both the substrate and sorbent and possessed ultra-high strength and stability. Great extraction efficiency toward PAHs was obtained by stainless steel loop without any modification, with enrichment factors of 651-834. By connecting the stainless steel loop onto a six-port valve, an online SPME-HPLC system was set up and an SPME-HPLC method has been validated for determination of PAHs. The method has exceptionally low limits of detection of 0.2-2pg/mL, which is significantly lower than that of reported methods with different kinds of sorbents. Wide linear range (0.5-500 and 2-1000pg/mL), good linearity (R(2)≥0.9987) and good reproducibility (RSD≤2.9%) were also obtained. The proposed method has been applied to determine PAHs in environmental samples. Good recoveries were obtained, ranging from 88.5% to 93.8%. Copyright © 2014 Elsevier B.V. All rights reserved.
Ishikawa, Seiko; Iimori, Soichiro; Takahashi, Daiei; Zeniya, Moko; Sato, Hidehiko; Nomura, Naohiro; Sohara, Eisei; Okado, Tomokazu; Uchida, Shinichi; Rai, Tatemitsu
2018-01-01
Introduction Sarcopenia, the age-related loss of muscle mass and function, frequently accompanies chronic kidney disease. The aim of this study was to clarify the prevalence and the risk factors for sarcopenia among patients with non-dialysis-dependent chronic kidney disease (NDD-CKD), focusing on the use of drugs. Methods We conducted a cross-sectional analysis on a cohort of 260 patients with NDD-CKD in a university hospital, recruited between June 2016 and March 2017. We extracted data on patient gender, age, cause of chronic kidney disease, use of drugs, and comorbidities that could potentially affect the prevalence of sarcopenia. Sarcopenia was diagnosed using the criteria of the Asian Working Group for Sarcopenia. Logistic regression analysis was performed to analyze the association of each factor on the prevalence of sarcopenia. Results 25.0% of our study subjects had sarcopenia. Multivariable analysis revealed that an increased risk of sarcopenia was significantly associated with age, male gender, body mass index, diabetes mellitus, and loop diuretic use (odds ratio, 4.59: 95% confidence interval, 1.81–11.61: P-value 0.001). Conclusions In our cohort, the prevalence of sarcopenia in patients with NDD-CKD was high, and diuretics use, particularly loop diuretic use, was suggested to be a risk factor of sarcopenia. Although loop diuretics are commonly used in patients with CKD, careful consideration of the risk of sarcopenia may be necessary. PMID:29447254
Tavakoli, A.; Mahmoodifard, M.; Razavifard, A. H.
2016-01-01
Prophylactic gastropexy is a procedure that prevents the occurrence of a life threatening condition known as gastric dilation and volvulus (GDV) in dogs. The objective of this study was to compare incisional, belt loop and minimally invasive endoscopically assisted gastropexy by evaluating different parameters such as surgical time, length of scar and score of pain in dogs. Twenty-one healthy, mixed-breed adult dogs weighting 14.3 ± 2.6 kg were randomly divided into three groups. Three gastropexy techniques applied in the following order: incisional (group I), belt loop (group B), and endoscopically assisted gastropexy (group E). Surgical time, anesthetic time, length of surgical incision and score of pain 3 h after surgery were recorded for all dogs. Two weeks after the surgery, positive-contrast gastrography was used to evaluate stomach position and total gastric emptying time. Ultrasonography was also used to evaluate the gastropexy two months after the surgery. Adhesion was confirmed two months after the surgery between the stomach wall at the pyloric antrum and the right side of the body wall in all dogs by ultrasound. The mean surgical time, length of surgical incision and score of pain were significantly lower in group E compared to group I and B (P<0.05). No significant differences were found in total gastric emptying time and gastropexy thickness post-operatively (P>0.05). Due to advantages observed in the current study, the endoscopically assisted technique seems to be a suitable alternative to open incisional and belt loop gastropexies for performing prophylactic gastropexy, especially when performed by skilled surgeons. PMID:27822237
Ferrite core coupled slapper detonator apparatus and method
Boberg, Ralph E.; Lee, Ronald S.; Weingart, Richard C.
1989-01-01
Method and apparatus are provided for coupling a temporally short electric power pulse from a thick flat-conductor power cable into a thin flat-conductor slapper detonator circuit. A first planar and generally circular loop is formed from an end portion of the power cable. A second planar and generally circular loop, of similar diameter, is formed from all or part of the slapper detonator circuit. The two loops are placed together, within a ferrite housing that provides a ferrite path that magnetically couples the two loops. Slapper detonator parts may be incorporated within the ferrite housing. The ferrite housing may be made vacuum and water-tight, with the addition of a hermetic ceramic seal, and provided with an enclosure for protecting the power cable and parts related thereto.
Ferrite core coupled slapper detonator apparatus and method
Boberg, R.E.; Lee, R.S.; Weingart, R.C.
1989-08-01
Method and apparatus are provided for coupling a temporally short electric power pulse from a thick flat-conductor power cable into a thin flat-conductor slapper detonator circuit. A first planar and generally circular loop is formed from an end portion of the power cable. A second planar and generally circular loop, of similar diameter, is formed from all or part of the slapper detonator circuit. The two loops are placed together, within a ferrite housing that provides a ferrite path that magnetically couples the two loops. Slapper detonator parts may be incorporated within the ferrite housing. The ferrite housing may be made vacuum and water-tight, with the addition of a hermetic ceramic seal, and provided with an enclosure for protecting the power cable and parts related thereto. 10 figs.
Two-loop mass splittings in electroweak multiplets: Winos and minimal dark matter
NASA Astrophysics Data System (ADS)
McKay, James; Scott, Pat
2018-03-01
The radiatively-induced splitting of masses in electroweak multiplets is relevant for both collider phenomenology and dark matter. Precision two-loop corrections of O (MeV ) to the triplet mass splitting in the wino limit of the minimal supersymmetric standard model can affect particle lifetimes by up to 40%. We improve on previous two-loop self-energy calculations for the wino model by obtaining consistent input parameters to the calculation via two-loop renormalization-group running, and including the effect of finite light quark masses. We also present the first two-loop calculation of the mass splitting in an electroweak fermionic quintuplet, corresponding to the viable form of minimal dark matter (MDM). We place significant constraints on the lifetimes of the charged and doubly-charged fermions in this model. We find that the two-loop mass splittings in the MDM quintuplet are not constant in the large-mass limit, as might naively be expected from the triplet calculation. This is due to the influence of the additional heavy fermions in loop corrections to the gauge boson propagators.
Two methods for increased specificity and sensitivity in loop-mediated isothermal amplification
USDA-ARS?s Scientific Manuscript database
The technique of loop-mediated isothermal amplification (LAMP) utilizes 4 (or 6) primers targeting 6 (or 8) regions within a fairly small segment of a genome for amplification, with concentration higher than that used in traditional PCR methods. The high concentrations of primers used leads to an in...
Rangan, Aaditya V; McGrouther, Caroline C; Kelsoe, John; Schork, Nicholas; Stahl, Eli; Zhu, Qian; Krishnan, Arjun; Yao, Vicky; Troyanskaya, Olga; Bilaloglu, Seda; Raghavan, Preeti; Bergen, Sarah; Jureus, Anders; Landen, Mikael
2018-05-14
A common goal in data-analysis is to sift through a large data-matrix and detect any significant submatrices (i.e., biclusters) that have a low numerical rank. We present a simple algorithm for tackling this biclustering problem. Our algorithm accumulates information about 2-by-2 submatrices (i.e., 'loops') within the data-matrix, and focuses on rows and columns of the data-matrix that participate in an abundance of low-rank loops. We demonstrate, through analysis and numerical-experiments, that this loop-counting method performs well in a variety of scenarios, outperforming simple spectral methods in many situations of interest. Another important feature of our method is that it can easily be modified to account for aspects of experimental design which commonly arise in practice. For example, our algorithm can be modified to correct for controls, categorical- and continuous-covariates, as well as sparsity within the data. We demonstrate these practical features with two examples; the first drawn from gene-expression analysis and the second drawn from a much larger genome-wide-association-study (GWAS).
Closed Loop System Identification with Genetic Algorithms
NASA Technical Reports Server (NTRS)
Whorton, Mark S.
2004-01-01
High performance control design for a flexible space structure is challenging since high fidelity plant models are di.cult to obtain a priori. Uncertainty in the control design models typically require a very robust, low performance control design which must be tuned on-orbit to achieve the required performance. Closed loop system identi.cation is often required to obtain a multivariable open loop plant model based on closed-loop response data. In order to provide an accurate initial plant model to guarantee convergence for standard local optimization methods, this paper presents a global parameter optimization method using genetic algorithms. A minimal representation of the state space dynamics is employed to mitigate the non-uniqueness and over-parameterization of general state space realizations. This control-relevant system identi.cation procedure stresses the joint nature of the system identi.cation and control design problem by seeking to obtain a model that minimizes the di.erence between the predicted and actual closed-loop performance.
Noncoherent Symbol Synchronization Techniques
NASA Technical Reports Server (NTRS)
Simon, Marvin
2005-01-01
Traditional methods for establishing symbol synchronization (sync) in digital communication receivers assume that carrier sync has already been established, i.e., the problem is addressed at the baseband level assuming that a 'perfect' estimate of carrier phase is available. We refer to this approach as coherent symbol sync. Since, for NRZ signaling, a suppressed carrier sync loop such as an I-Q Costas loop includes integrate-and-dump (I and D) filters in its in-phase (1) and quadrature (Q) arms, the traditional approach is to first track the carrier in the absence of symbol sync information, then feed back the symbol sync estimate to these filters, and then iterate between the two to a desirable operating level In this paper, we revisit the symbol sync problem by examining methods for obtaining such sync in the absence of carrier phase information, i.e., so-called noncoherent symbol sync loops. We compare the performance of these loops with that of a well-known coherent symbol sync loop and examine the conditions under which one is preferable over the other.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weinzierl, Stefan
2011-10-01
This article discusses the occurrence of one-loop amplitudes within a next-to-next-to-leading-order calculation. In a next-to-next-to-leading-order calculation, the one-loop amplitude enters squared and one would therefore naively expect that the O({epsilon})- and O({epsilon}{sup 2})-terms of the one-loop amplitudes are required. I show that the calculation of these terms can be avoided if a method is known, which computes the O({epsilon}{sup 0})-terms of the finite remainder function of the two-loop amplitude.
Loop Heat Pipe Startup Behaviors
NASA Technical Reports Server (NTRS)
Ku, Jentung
2016-01-01
A loop heat pipe must start successfully before it can commence its service. The startup transient represents one of the most complex phenomena in the loop heat pipe operation. This paper discusses various aspects of loop heat pipe startup behaviors. Topics include the four startup scenarios, the initial fluid distribution between the evaporator and reservoir that determines the startup scenario, factors that affect the fluid distribution between the evaporator and reservoir, difficulties encountered during the low power startup, and methods to enhance the startup success. Also addressed are the pressure spike and pressure surge during the startup transient, and repeated cycles of loop startup and shutdown under certain conditions.
Simplified formula for mean cycle-slip time of phase-locked loops with steady-state phase error.
NASA Technical Reports Server (NTRS)
Tausworthe, R. C.
1972-01-01
Previous work shows that the mean time from lock to a slipped cycle of a phase-locked loop is given by a certain double integral. Accurate numerical evaluation of this formula for the second-order loop is extremely vexing because the difference between exponentially large quantities is involved. The presented article demonstrates a method in which a much-reduced precision program can be used to obtain the mean first-cycle slip time for a loop of arbitrary degree tracking at a specified SNR and steady-state phase error. It also presents a simple approximate formula that is asymptotically tight at higher loop SNR.
Higgs boson self-coupling from two-loop analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alhendi, H. A.; National Center for Mathematics and Physics, KACST P. O. Box 6086, Riyadh 11442; Barakat, T.
2010-09-01
The scale invariant of the effective potential of the standard model at two loop is used as a boundary condition under the assumption that the two-loop effective potential approximates the full effective potential. This condition leads with the help of the renormalization-group functions of the model at two loop to an algebraic equation of the scalar self-coupling with coefficients that depend on the gauge and the top quark couplings. It admits only two real positive solutions. One of them, in the absence of the gauge and top quark couplings, corresponds to the nonperturbative ultraviolet fixed point of the scalar renormalization-groupmore » function and the other corresponds to the perturbative infrared fixed point. The dependence of the scalar coupling on the top quark and the strong couplings at two-loop radiative corrections is analyzed.« less
Closed loop statistical performance analysis of N-K knock controllers
NASA Astrophysics Data System (ADS)
Peyton Jones, James C.; Shayestehmanesh, Saeed; Frey, Jesse
2017-09-01
The closed loop performance of engine knock controllers cannot be rigorously assessed from single experiments or simulations because knock behaves as a random process and therefore the response belongs to a random distribution also. In this work a new method is proposed for computing the distributions and expected values of the closed loop response, both in steady state and in response to disturbances. The method takes as its input the control law, and the knock propensity characteristic of the engine which is mapped from open loop steady state tests. The method is applicable to the 'n-k' class of knock controllers in which the control action is a function only of the number of cycles n since the last control move, and the number k of knock events that have occurred in this time. A Cumulative Summation (CumSum) based controller falls within this category, and the method is used to investigate the performance of the controller in a deeper and more rigorous way than has previously been possible. The results are validated using onerous Monte Carlo simulations, which confirm both the validity of the method and its high computational efficiency.
Kamisetty, Supradeep Kumar; N, Raghuveer; N, Rajavikram; N, Chakrapani; Dwaragesh; Praven
2014-07-01
Evaluations on retraction loop designs have been limited to describe the force systems applied to the buccal surfaces of the tooth that can be in different planes resulting undesirable effects, needing corrective action in future. By initially understanding these effects, modifications to the loop design can essentially counteract the undesired affects. To deter-mine Moments & M/F ratios produced by different gabling in the three retraction loops (Tear drop loop, T-loop, Open vertical loop) and movement of the anterior teeth and posterior teeth) of the maxillary arch in an extraction model, on activation of three retraction loops by1 mm. A PC with Quad core processor, 8GB RAM, 1TB storage space and Graphic Accelerator was used. Computer Software: ANSYS Version11, PRO/ENGINEER was used in the study. The first step is modeling, done by using Pro/Engineer software and for creating a model the CT scan data is required. The maxilla with teeth of a patient is scanned at various sections at regular intervals of 0.5 mm. These scanned images are then imported into Pro/E software to various offset planes. Once imported, the software can do an automatic meshing and establishes contact automatically. When angulations increases intrusive or extrusive movements and movements in horizontal direction of crown tip and root tip increases. All values of T-loop are more than Teardrop loop and less than Open vertical loop. FEM study concludes that Teardrop loop with 10-20(α-β) combination is preferred for Group A anchorage.
The 1-loop effective potential for the Standard Model in curved spacetime
NASA Astrophysics Data System (ADS)
Markkanen, Tommi; Nurmi, Sami; Rajantie, Arttu; Stopyra, Stephen
2018-06-01
The renormalisation group improved Standard Model effective potential in an arbitrary curved spacetime is computed to one loop order in perturbation theory. The loop corrections are computed in the ultraviolet limit, which makes them independent of the choice of the vacuum state and allows the derivation of the complete set of β-functions. The potential depends on the spacetime curvature through the direct non-minimal Higgs-curvature coupling, curvature contributions to the loop diagrams, and through the curvature dependence of the renormalisation scale. Together, these lead to significant curvature dependence, which needs to be taken into account in cosmological applications, which is demonstrated with the example of vacuum stability in de Sitter space.
NASA Astrophysics Data System (ADS)
Matsudo, Ryutaro; Kondo, Kei-Ichi
2015-12-01
We give a gauge-independent definition of magnetic monopoles in the S U (N ) Yang-Mills theory through the Wilson loop operator. For this purpose, we give an explicit proof of the Diakonov-Petrov version of the non-Abelian Stokes theorem for the Wilson loop operator in an arbitrary representation of the S U (N ) gauge group to derive a new form for the non-Abelian Stokes theorem. The new form is used to extract the magnetic-monopole contribution to the Wilson loop operator in a gauge-invariant way, which enables us to discuss confinement of quarks in any representation from the viewpoint of the dual superconductor vacuum.
Magnetic antenna excitation of whistler modes. III. Group and phase velocities of wave packets
NASA Astrophysics Data System (ADS)
Urrutia, J. M.; Stenzel, R. L.
2015-07-01
The properties of whistler modes excited by single and multiple magnetic loop antennas have been investigated in a large laboratory plasma. A single loop excites a wavepacket, but an array of loops across the ambient magnetic field B0 excites approximate plane whistler modes. The single loop data are measured. The array patterns are obtained by linear superposition of experimental data shifted in space and time, which is valid in a uniform plasma and magnetic field for small amplitude waves. Phasing the array changes the angle of wave propagation. The antennas are excited by an rf tone burst whose propagating envelope and oscillations yield group and phase velocities. A single loop antenna with dipole moment across B0 excites wave packets whose topology resembles m = 1 helicon modes, but without radial boundaries. The phase surfaces are conical with propagation characteristics of Gendrin modes. The cones form near the antenna with comparable parallel and perpendicular phase velocities. A physical model for the wave excitation is given. When a wave burst is applied to a phased antenna array, the wave front propagates both along the array and into the plasma forming a "whistler wing" at the front. These laboratory observations may be relevant for excitation and detection of whistler modes in space plasmas.
Martin, Jaclyn; Carrillo, Yisel; Talley, Justin L.; Ochoa-Corona, Francisco M.
2018-01-01
Background The importance of tick and flea-borne rickettsia infections is increasingly recognized worldwide. While increased focus has shifted in recent years to the development of point-of-care diagnostics for various vector-borne diseases in humans and animals, little research effort has been devoted to their integration into vector surveillance and control programs, particularly in resource-challenged countries. One technology which may be helpful for large scale vector surveillance initiatives is loop-mediated isothermal amplification (LAMP). The aim of this study was to develop a LAMP assay to detect spotted fever group (SFG) rickettsia DNA from field-collected ticks and fleas and compare with published end-point PCR results. Methodology/Principal findings A Spotted Fever Group rickettsia-specific loop-mediated isothermal amplification (SFGR-LAMP) assay was developed using primers based on a region of the R. rickettsii 17kDa protein gene. The sensitivity, specificity, and reproducibility of the assay were evaluated. The assay was then compared with the results of end-point PCR assays for pooled tick and flea samples obtained from field-based surveillance studies. The sensitivity of the SFGR-LAMP assay was 0.00001 ng/μl (25μl volume) which was 10 times more sensitive than the 17kDa protein gene end-point PCR used as the reference method. The assay only recognized gDNA from SFG and transitional group (TRG) rickettsia species tested but did not detect gDNA from typhus group (TG) rickettsia species or closely or distantly related bacterial species. The SFGR-LAMP assay detected the same positives from a set of pooled tick and flea samples detected by end-point PCR in addition to two pooled flea samples not detected by end-point PCR. Conclusions/significance To our knowledge, this is the first study to develop a functional LAMP assay to initially screen for SFG and TRG rickettsia pathogens in field-collected ticks and fleas. With a high sensitivity and specificity, the results indicate the potential use as a field-based surveillance tool for tick and flea-borne rickettsial pathogens in resource-challenged countries. PMID:29390021
Noden, Bruce H; Martin, Jaclyn; Carrillo, Yisel; Talley, Justin L; Ochoa-Corona, Francisco M
2018-01-01
The importance of tick and flea-borne rickettsia infections is increasingly recognized worldwide. While increased focus has shifted in recent years to the development of point-of-care diagnostics for various vector-borne diseases in humans and animals, little research effort has been devoted to their integration into vector surveillance and control programs, particularly in resource-challenged countries. One technology which may be helpful for large scale vector surveillance initiatives is loop-mediated isothermal amplification (LAMP). The aim of this study was to develop a LAMP assay to detect spotted fever group (SFG) rickettsia DNA from field-collected ticks and fleas and compare with published end-point PCR results. A Spotted Fever Group rickettsia-specific loop-mediated isothermal amplification (SFGR-LAMP) assay was developed using primers based on a region of the R. rickettsii 17kDa protein gene. The sensitivity, specificity, and reproducibility of the assay were evaluated. The assay was then compared with the results of end-point PCR assays for pooled tick and flea samples obtained from field-based surveillance studies. The sensitivity of the SFGR-LAMP assay was 0.00001 ng/μl (25μl volume) which was 10 times more sensitive than the 17kDa protein gene end-point PCR used as the reference method. The assay only recognized gDNA from SFG and transitional group (TRG) rickettsia species tested but did not detect gDNA from typhus group (TG) rickettsia species or closely or distantly related bacterial species. The SFGR-LAMP assay detected the same positives from a set of pooled tick and flea samples detected by end-point PCR in addition to two pooled flea samples not detected by end-point PCR. To our knowledge, this is the first study to develop a functional LAMP assay to initially screen for SFG and TRG rickettsia pathogens in field-collected ticks and fleas. With a high sensitivity and specificity, the results indicate the potential use as a field-based surveillance tool for tick and flea-borne rickettsial pathogens in resource-challenged countries.
Wilson loops in supersymmetric gauge theories
NASA Astrophysics Data System (ADS)
Pestun, Vasily
This thesis is devoted to several exact computations in four-dimensional supersymmetric gauge field theories. In the first part of the thesis we prove conjecture due to Erickson-Semenoff-Zarembo and Drukker-Gross which relates supersymmetric circular Wilson loop operators in the N = 4 supersymmetric Yang-Mills theory with a Gaussian matrix model. We also compute the partition function and give a new matrix model formula for the expectation value of a supersymmetric circular Wilson loop operator for the pure N = 2 and the N* = 2 supersymmetric Yang-Mills theory on a four-sphere. Circular supersymmetric Wilson loops in four-dimensional N = 2 superconformal gauge theory are treated similarly. In the second part we consider supersymmetric Wilson loops of arbitrary shape restricted to a two-dimensional sphere in the four-dimensional N = 4 supersymmetric Yang-Mills theory. We show that expectation value for these Wilson loops can be exactly computed using a two-dimensional theory closely related to the topological two-dimensional Higgs-Yang-Mills theory, or two-dimensional Yang-Mills theory for the complexified gauge group.
Comparison of the CO2 laser and Leep-Loop method in treatment of changes in uterine cervix
NASA Astrophysics Data System (ADS)
Wozniak, Jakub; Wilczak, Maciej; Sajdak, Stefan; Opala, Tomasz; Rabiega, Dorota
2000-11-01
Electric leep-loop and lasersurgery are modern methods in treatment of diseases of uterine cervix that we can use often exchangeable. Differences first of all relates indications. Lasersurgery we can apply in diseases of uterine cervix channel. Application of electric leep in dysplasia of small grade of uterus cervix channel is possible. Before lasersurgery we should exclude cervical carcinoma, because we don't have histopathological material. Leep-loop conisation we shouldn't apply at young women, who plan pregnancy (risk of cicatristaion and dystokia of uterine cervix.)
The Life Cycle Evaluation Model of External Diseconomy of Open-loop Supply Chain
NASA Astrophysics Data System (ADS)
Liu, Qian; Hu, Tianjun
2017-08-01
In recent years, with the continuous deterioration of pollution, resource space is gradually narrowed, the number of waste items increased, people began to use the method of recycling on waste products to ease the pressure on the environment. This paper adopted the external diseconomy of open-loop supply chain as the research object and constructed the model by the life cycle evaluation method, comparative analysis through the case. This paper also concludes that the key to solving the problem is to realize the closed-loop supply chain and building reverse logistics system is of great significance.
Pley, H W; Flaherty, K M; McKay, D B
1994-11-03
In large structured RNAs, RNA hairpins in which the strands of the duplex stem are connected by a tetraloop of the consensus sequence 5'-GNRA (where N is any nucleotide, and R is either G or A) are unusually frequent. In group I introns there is a covariation in sequence between nucleotides in the third and fourth positions of the loop with specific distant base pairs in putative RNA duplex stems: GNAA loops correlate with successive 5'-C-C.G-C base pairs in stems, whereas GNGA loops correlate with 5'-C-U.G-A. This has led to the suggestion that GNRA tetraloops may be involved in specific long-range tertiary interactions, with each A in position 3 or 4 of the loop interacting with a C-G base pair in the duplex, and G in position 3 interacting with a U-A base pair. This idea is supported experimentally for the GAAA loop of the P5b extension of the group I intron of Tetrahymena thermophila and the L9 GUGA terminal loop of the td intron of bacteriophage T4 (ref. 4). NMR has revealed the overall structure of the tetraloop for 12-nucleotide hairpins with GCAA and GAAA loops and models have been proposed for the interaction of GNRA tetraloops with base pairs in the minor groove of A-form RNA. Here we describe the crystal structure of an intermolecular complex between a GAAA tetraloop and an RNA helix. The interactions we observe correlate with the specificity of GNRA tetraloops inferred from phylogenetic studies, suggesting that this complex is a legitimate model for intramolecular tertiary interactions mediated by GNRA tetraloops in large structured RNAs.
Lee, Kil Yong; Burnett, William C
A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 °C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods.
Camp, Jeremy V; Nowotny, Norbert
2016-10-01
The development of reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assays are described herein for the detection of two orthobunyaviruses (Bunyaviridae), which represent the two main serogroups found in mosquitoes in Central Europe. The RT-LAMP assays were optimized for the detection of Ťahyňa virus (a California encephalitis group virus found in Aedes sp or Ochlerotatus sp mosquitoes) and Batai virus (also called Čalovo virus, a Bunyamwera group virus found in Anopheles maculipennis s.l. mosquitoes) nucleic acid using endemic European virus isolates. The sensitivity of the RT-LAMP assays was determined to be comparable to that of conventional tests, with a limit of detection<0.1 pfu per reaction. The assays can be performed in 60min under isothermal conditions using very simple equipment. Furthermore, it was possible to proceed with the assays without nucleic acid extraction, albeit at a 100-fold loss of sensitivity. The RT-LAMP assays are a sensitive, cost-efficient method for both arbovirus surveillance as well as diagnostic laboratories to detect the presence of these endemic orthobunyaviruses. Copyright © 2016 Elsevier B.V. All rights reserved.
Controlled-Root Approach To Digital Phase-Locked Loops
NASA Technical Reports Server (NTRS)
Stephens, Scott A.; Thomas, J. Brooks
1995-01-01
Performance tailored more flexibly and directly to satisfy design requirements. Controlled-root approach improved method for analysis and design of digital phase-locked loops (DPLLs). Developed rigorously from first principles for fully digital loops, making DPLL theory and design simpler and more straightforward (particularly for third- or fourth-order DPLL) and controlling performance more accurately in case of high gain.
Huang, Xiao-Ying; Li, Hong; Xu, Xiao-Mei; Wang, Liang-Xing
2014-08-01
The aim of the present study was to analyze the differences between the genes of the mitochondrial DNA (mtDNA) displacement loop (D-loop) region and the Cambridge Reference sequence, in order to screen the mutation sites and investigate the correlation between mutations, clinical parameters and complications associated with obstructive sleep apnea-hypopnea syndrome (OSAHS). mtDNA was obtained from male patients with OSAHS in the Zhejiang Province. In total, 60 male patients with OSAHS and 102 healthy adults were assessed to determine the levels of fasting blood glucose, total cholesterol, triglyceride (TG) and high-density and low-density lipoproteins (LDL). Furthermore, peripheral mtDNA was extracted and bidirectional sequencing was conducted to enable mutation screening. In the mtDNA D-loop region, 178 mutation sites were identified, of which 115 sites were present in the two groups. The number of non-common sites in the OSAHS group was significantly higher compared with the control group (P<0.05). No statistically significant difference was observed in the mutations among the mild, moderate and severe OSAHS groups (P>0.05). A total of 21 cases in the severe OSAHS group exhibited mutation rates of >10%. In the control group, there were 24 cases where the np73A-G and np263A-G mutations were predominant. The np303-np315 region was identified to be the highly variable region and various mutation forms were observed. Statistically significant differences were observed in the neck perimeter, TG and LDL levels among the OSAHS-no-mutation subgroups (P<0.05) and LDL was shown to be associated with an mtDNA mutation in the OSAHS group. Numerous polymorphic mutation sites were identified in the mtDNA D-loop region of the OSAHS group. Therefore, mtDNA mutation sites may be closely associated with the clinical manifestations and complications of OSAHS.
THE CORONAL LOOP INVENTORY PROJECT: EXPANDED ANALYSIS AND RESULTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmelz, J. T.; Christian, G. M.; Chastain, R. A., E-mail: jschmelz@usra.edu
We have expanded upon earlier work that investigates the relative importance of coronal loops with isothermal versus multithermal cross-field temperature distributions. These results are important for determining if loops have substructure in the form of unresolved magnetic strands. We have increased the number of loops targeted for temperature analysis from 19 to 207 with the addition of 188 new loops from multiple regions. We selected all loop segments visible in the 171 Å images of the Atmospheric Imaging Assembly (AIA) that had a clean background. Eighty-six of the new loops were rejected because they could not be reliably separated frommore » the background in other AIA filters. Sixty-one loops required multithermal models to reproduce the observations. Twenty-eight loops were effectively isothermal, that is, the plasma emission to which AIA is sensitive could not be distinguished from isothermal emission, within uncertainties. Ten loops were isothermal. Also, part of our inventory was one small flaring loop, one very cool loop whose temperature distribution could not be constrained by the AIA data, and one loop with inconclusive results. Our survey can confirm an unexpected result from the pilot study: we found no isothermal loop segments where we could properly use the 171-to-193 ratio method, which would be similar to the analysis done for many loops observed with TRACE and EIT. We recommend caution to observers who assume the loop plasma is isothermal, and hope that these results will influence the direction of coronal heating models and the effort modelers spend on various heating scenarios.« less
Pulsatile desynchronizing delayed feedback for closed-loop deep brain stimulation
Lysyansky, Borys; Rosenblum, Michael; Pikovsky, Arkady; Tass, Peter A.
2017-01-01
High-frequency (HF) deep brain stimulation (DBS) is the gold standard for the treatment of medically refractory movement disorders like Parkinson’s disease, essential tremor, and dystonia, with a significant potential for application to other neurological diseases. The standard setup of HF DBS utilizes an open-loop stimulation protocol, where a permanent HF electrical pulse train is administered to the brain target areas irrespectively of the ongoing neuronal dynamics. Recent experimental and clinical studies demonstrate that a closed-loop, adaptive DBS might be superior to the open-loop setup. We here combine the notion of the adaptive high-frequency stimulation approach, that aims at delivering stimulation adapted to the extent of appropriately detected biomarkers, with specifically desynchronizing stimulation protocols. To this end, we extend the delayed feedback stimulation methods, which are intrinsically closed-loop techniques and specifically designed to desynchronize abnormal neuronal synchronization, to pulsatile electrical brain stimulation. We show that permanent pulsatile high-frequency stimulation subjected to an amplitude modulation by linear or nonlinear delayed feedback methods can effectively and robustly desynchronize a STN-GPe network of model neurons and suggest this approach for desynchronizing closed-loop DBS. PMID:28273176
Rinehart, Joseph; Lilot, Marc; Lee, Christine; Joosten, Alexandre; Huynh, Trish; Canales, Cecilia; Imagawa, David; Demirjian, Aram; Cannesson, Maxime
2015-03-19
Goal-directed fluid therapy strategies have been shown to benefit moderate- to high-risk surgery patients. Despite this, these strategies are often not implemented. The aim of this study was to assess a closed-loop fluid administration system in a surgical cohort and compare the results with those for matched patients who received manual management. Our hypothesis was that the patients receiving closed-loop assistance would spend more time in a preload-independent state, defined as percentage of case time with stroke volume variation less than or equal to 12%. Patients eligible for the study were all those over 18 years of age scheduled for hepatobiliary, pancreatic or splenic surgery and expected to receive intravascular arterial blood pressure monitoring as part of their anesthetic care. The closed-loop resuscitation target was selected by the primary anesthesia team, and the system was responsible for implementation of goal-directed fluid therapy during surgery. Following completion of enrollment, each study patient was matched to a non-closed-loop assisted case performed during the same time period using a propensity match to reduce bias. A total of 40 patients were enrolled, 5 were ultimately excluded and 25 matched pairs were selected from among the remaining 35 patients within the predefined caliper distance. There was no significant difference in fluid administration between groups. The closed-loop group spent a significantly higher portion of case time in a preload-independent state (95 ± 6% of case time versus 87 ± 14%, P =0.008). There was no difference in case mean or final stroke volume index (45 ± 10 versus 43 ± 9 and 45 ± 11 versus 42 ± 11, respectively) or mean arterial pressure (79 ± 8 versus 83 ± 9). Case end heart rate was significantly lower in the closed-loop assisted group (77 ± 10 versus 88 ± 13, P =0.003). In this case-control study with propensity matching, clinician use of closed-loop assistance resulted in a greater portion of case time spent in a preload-independent state throughout surgery compared with manual delivery of goal-directed fluid therapy. ClinicalTrials.gov Identifier: NCT02020863. Registered 19 December 2013.
Edge-on dislocation loop in anisotropic hcp zirconium thin foil
NASA Astrophysics Data System (ADS)
Wu, Wenwang; Xia, Re; Qian, Guian; Xu, Shucai; Zhang, Jinhuan
2015-10-01
Edge-on dislocation loops with 〈 a 〉 -type and 〈 c 〉 -type of Burgers vectors can be formed on prismatic or basel habit planes of hexagonal close-packed (hcp) zirconium alloys during in-situ ion irradiation and neutron irradiation experiments. In this work, an anisotropic image stress method was employed to analyze the free surface effects of dislocation loops within hcp Zr thin foils. Calculation results demonstrate that image stress has a remarkable effect on the distortion fields of dislocation loops within infinite medium, and the image energy becomes remarkable when dislocation loops are situated close to the free surfaces. Moreover, image forces of the 1 / 2 〈 0001 〉 (0001) dislocation loop within (0001) thin foil is much stronger than that of the 1 / 3 〈 11 2 bar 0 〉 (11 2 bar 0) dislocation loop within (11 2 bar 0) thin foil of identical geometrical configurations. Finally, image stress effect on the physical behaviors of loops during in-situ ion irradiation experiments is discussed.
Trajectory tracking control for underactuated stratospheric airship
NASA Astrophysics Data System (ADS)
Zheng, Zewei; Huo, Wei; Wu, Zhe
2012-10-01
Stratospheric airship is a new kind of aerospace system which has attracted worldwide developing interests for its broad application prospects. Based on the trajectory linearization control (TLC) theory, a novel trajectory tracking control method for an underactuated stratospheric airship is presented in this paper. Firstly, the TLC theory is described sketchily, and the dynamic model of the stratospheric airship is introduced with kinematics and dynamics equations. Then, the trajectory tracking control strategy is deduced in detail. The designed control system possesses a cascaded structure which consists of desired attitude calculation, position control loop and attitude control loop. Two sub-loops are designed for the position and attitude control loops, respectively, including the kinematics control loop and dynamics control loop. Stability analysis shows that the controlled closed-loop system is exponentially stable. Finally, simulation results for the stratospheric airship to track typical trajectories are illustrated to verify effectiveness of the proposed approach.
Integrated Research/Education University Aircraft Design Program Development
2017-04-06
iterations and loop shaping compared to MIMO control methods. Despite the drawbacks, loop closure and classical methods are the design methods most commonly...AFRL-AFOSR-VA-TR-2017-0077 Integrated Research/Education University Aircraft Design Program Development Eli Livne UNIVERSITY OF WASHINGTON 4333...SUBTITLE Integrated Research/Education University Aircraft Design Program Development 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA9550-14-1-0027 5c. PROGRAM
Loop Heat Pipe Startup Behaviors
NASA Technical Reports Server (NTRS)
Ku, Jentung
2014-01-01
A loop heat pipe must start successfully before it can commence its service. The start-up transient represents one of the most complex phenomena in the loop heat pipe operation. This paper discusses various aspects of loop heat pipe start-up behaviors. Topics include the four start-up scenarios, the initial fluid distribution between the evaporator and reservoir that determines the start-up scenario, factors that affect the fluid distribution between the evaporator and reservoir, difficulties encountered during the low power start-up, and methods to enhance the start-up success. Also addressed are the thermodynamic constraint between the evaporator and reservoir in the loop heat pipe operation, the superheat requirement for nucleate boiling, pressure spike and pressure surge during the start-up transient, and repeated cycles of loop start-up andshutdown under certain conditions.
Pricop, Catalin; Serban, Dragomir N; Serban, Ionela Lacramioara; Cumpanas, Alin-Adrian; Gingu, Constantin-Virgil
2016-01-01
JJ stents are often encountered in patients with pelvic renal stones referred for shock wave lithotripsy, most of them being placed either for obstructive renal pelvic stones or for ureteric stones mobilized retrograde during the JJ stent insertion. The aim of the study was to determine whether the relative stone position in the upper loop of the JJ stent during extracorporeal shock wave lithotripsy (SWL) influences the efficiency of the procedure. The study was designed as a prospective cohort study on 162 patients addressing the same urological department, with single renal pelvic stone (primary or mobilized to the renal pelvis during the insertion of JJ stent), smaller than 15 mm, with JJ stent, treated by SWL using a second generation spark gap lithotripter, 18 kV, 3000 waves/session. Patients were divided in three groups according to the relative position of the stone to the upper loop of the JJ stent as appears on plain X-ray: stone-inside-loop, loop-crossing-stone and stone-outside the loop. The SWL success rate was the primary outcome of the study. p Value, Chi square and Kruskal-Wallis tests were used for statistical analysis. For stone-inside-loop cases, SWL efficiency was 22.7 versus 42 % for all the other cases (p = 0.002). Other factors for decreased SWL success rate were: higher stone radio-opacity, larger JJ of stent and obese patients. Study limitation is represented by the relative small study group and by the evaluation of stone density using plain X-ray instead of computer tomography. For pelvic renal stones having the same density characteristics studied by plain X-ray, the SWL efficiency is lower in stone-inside-loop cases comparing with the other positions. The overall stone free rate for renal pelvic stones could be explained by the second generation lithotripter used for all procedures.
Validating a Coarse-Grained Potential Energy Function through Protein Loop Modelling
MacDonald, James T.; Kelley, Lawrence A.; Freemont, Paul S.
2013-01-01
Coarse-grained (CG) methods for sampling protein conformational space have the potential to increase computational efficiency by reducing the degrees of freedom. The gain in computational efficiency of CG methods often comes at the expense of non-protein like local conformational features. This could cause problems when transitioning to full atom models in a hierarchical framework. Here, a CG potential energy function was validated by applying it to the problem of loop prediction. A novel method to sample the conformational space of backbone atoms was benchmarked using a standard test set consisting of 351 distinct loops. This method used a sequence-independent CG potential energy function representing the protein using -carbon positions only and sampling conformations with a Monte Carlo simulated annealing based protocol. Backbone atoms were added using a method previously described and then gradient minimised in the Rosetta force field. Despite the CG potential energy function being sequence-independent, the method performed similarly to methods that explicitly use either fragments of known protein backbones with similar sequences or residue-specific /-maps to restrict the search space. The method was also able to predict with sub-Angstrom accuracy two out of seven loops from recently solved crystal structures of proteins with low sequence and structure similarity to previously deposited structures in the PDB. The ability to sample realistic loop conformations directly from a potential energy function enables the incorporation of additional geometric restraints and the use of more advanced sampling methods in a way that is not possible to do easily with fragment replacement methods and also enable multi-scale simulations for protein design and protein structure prediction. These restraints could be derived from experimental data or could be design restraints in the case of computational protein design. C++ source code is available for download from http://www.sbg.bio.ic.ac.uk/phyre2/PD2/. PMID:23824634
Design of dissipative low-authority controllers using an eigensystem assignment technique
NASA Technical Reports Server (NTRS)
Maghami, P. G.; Gupta, S.; Joshi, S. M.
1992-01-01
A novel method for the design of dissipative, low-authority controllers has been developed. The method uses a sequential approach along with eigensystem assignment to compute rate and position gain matrices that assign a number of closed-loop poles of the system to desired locations. Because the feedback gain matrices are symmetric and nonnegative definite, the closed-loop stability is always guaranteed regardless of the model order or parameter inaccuracies. The resulting (nominal) closed-loop system can have specified damping ratios for m modes, which makes the plant amenable to high-authority controller design, using methods such as LQG/LTR or H-infinity. A numerical example is worked out for a flexible structure in order to demonstrate the proposed technique.
Digital capillaroscopy as important tool for early diagnostics of arterial hypertension
NASA Astrophysics Data System (ADS)
Gurfinkel, Yu. I.; Sasonko, M. L.; Priezzhev, A. V.
2015-03-01
The study is aimed to determine the digital capillaroscopy possibilities in early diagnostics of an arterial hypertension. A total of 123 adult persons were examined in the study. The first group consisted of 40 patients with prehypertension (BP 130-139/85-89 mm Hg). The second group included 36 patients with 1-2 stage of hypertension (mean systolic BP 152.7±12 mm Hg). Patients in both groups did not receive regular drug therapy. The group of volunteers (n=47) included healthy adults without signs of cardiovascular pathology. The capillary circulation was examined on the nailbed using the optical digital capillaroscope developed by the company "AET", Russia. Diameters of the arterial and venous segments, perivascular zone size, capillary blood velocity, the degree of arterial loops narrowing and the density of the capillary network were estimated. In patients with arterial hypertension and even in patients with prehypertension remodeling and rarefaction of capillaries and the expressed narrowing their arterial loops were manifested. The results of the study revealed the presence of abnormalities of microcirculation parameters in patients of both groups. The capillaries density in both groups of patients was significantly lower than in healthy persons. The significant narrowing of arterial loops was revealed in patients with both arterial hypertension and prehypertension, in comparison with healthy volunteers. Capillary blood velocity did not differ significantly between healthy volunteers group and the group of prehypertensive patients. However in patients with hypertension this parameter was significantly lower in comparison with control group.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Ning; Shen, Tielong; Kurtz, Richard
The properties of nano-scale interstitial dislocation loops under the coupling effect of stress and temperature are studied using atomistic simulation methods and experiments. The decomposition of a loop by the emission of smaller loops is identified as one of the major mechanisms to release the localized stress induced by the coupling effect, which is validated by the TEM observations. The classical conservation law of Burgers vector cannot be applied during such decomposition process. The dislocation network is formed from the decomposed loops, which may initiate the irradiation creep much earlier than expected through the mechanism of climb-controlled glide of dislocations.
NASA Astrophysics Data System (ADS)
Pascoe, D. J.; Anfinogentov, S.; Nisticò, G.; Goddard, C. R.; Nakariakov, V. M.
2017-04-01
Context. The strong damping of kink oscillations of coronal loops can be explained by mode coupling. The damping envelope depends on the transverse density profile of the loop. Observational measurements of the damping envelope have been used to determine the transverse loop structure which is important for understanding other physical processes such as heating. Aims: The general damping envelope describing the mode coupling of kink waves consists of a Gaussian damping regime followed by an exponential damping regime. Recent observational detection of these damping regimes has been employed as a seismological tool. We extend the description of the damping behaviour to account for additional physical effects, namely a time-dependent period of oscillation, the presence of additional longitudinal harmonics, and the decayless regime of standing kink oscillations. Methods: We examine four examples of standing kink oscillations observed by the Atmospheric Imaging Assembly (AIA) onboard the Solar Dynamics Observatory (SDO). We use forward modelling of the loop position and investigate the dependence on the model parameters using Bayesian inference and Markov chain Monte Carlo (MCMC) sampling. Results: Our improvements to the physical model combined with the use of Bayesian inference and MCMC produce improved estimates of model parameters and their uncertainties. Calculation of the Bayes factor also allows us to compare the suitability of different physical models. We also use a new method based on spline interpolation of the zeroes of the oscillation to accurately describe the background trend of the oscillating loop. Conclusions: This powerful and robust method allows for accurate seismology of coronal loops, in particular the transverse density profile, and potentially reveals additional physical effects.
Non-polynomial closed string field theory: loops and conformal maps
NASA Astrophysics Data System (ADS)
Hua, Long; Kaku, Michio
1990-11-01
Recently, we proposed the complete classical action for the non-polynomial closed string field theory, which succesfully reproduced all closed string tree amplitudes. (The action was simultaneously proposed by the Kyoto group). In this paper, we analyze the structure of the theory. We (a) compute the explicit conformal map for all g-loop, p-puncture diagrams, (b) compute all one-loop, two-puncture maps in terms of hyper-elliptic functions, and (c) analyze their modular structure. We analyze, but do not resolve, the question of modular invariance.
Conformal structure of massless scalar amplitudes beyond tree level
NASA Astrophysics Data System (ADS)
Banerjee, Nabamita; Banerjee, Shamik; Bhatkar, Sayali Atul; Jain, Sachin
2018-04-01
We show that the one-loop on-shell four-point scattering amplitude of massless ϕ 4 scalar field theory in 4D Minkowski space time, when Mellin transformed to the Celestial sphere at infinity, transforms covariantly under the global conformal group (SL(2, ℂ)) on the sphere. The unitarity of the four-point scalar amplitudes is recast into this Mellin basis. We show that the same conformal structure also appears for the two-loop Mellin amplitude. Finally we comment on some universal structure for all loop four-point Mellin amplitudes specific to this theory.
One-loop corrections to light cone wave functions: The dipole picture DIS cross section
NASA Astrophysics Data System (ADS)
Hänninen, H.; Lappi, T.; Paatelainen, R.
2018-06-01
We develop methods to perform loop calculations in light cone perturbation theory using a helicity basis, refining the method introduced in our earlier work. In particular this includes implementing a consistent way to contract the four-dimensional tensor structures from the helicity vectors with d-dimensional tensors arising from loop integrals, in a way that can be fully automatized. We demonstrate this explicitly by calculating the one-loop correction to the virtual photon to quark-antiquark dipole light cone wave function. This allows us to calculate the deep inelastic scattering cross section in the dipole formalism to next-to-leading order accuracy. Our results, obtained using the four dimensional helicity scheme, agree with the recent calculation by Beuf using conventional dimensional regularization, confirming the regularization scheme independence of this cross section.
Efficiently computing exact geodesic loops within finite steps.
Xin, Shi-Qing; He, Ying; Fu, Chi-Wing
2012-06-01
Closed geodesics, or geodesic loops, are crucial to the study of differential topology and differential geometry. Although the existence and properties of closed geodesics on smooth surfaces have been widely studied in mathematics community, relatively little progress has been made on how to compute them on polygonal surfaces. Most existing algorithms simply consider the mesh as a graph and so the resultant loops are restricted only on mesh edges, which are far from the actual geodesics. This paper is the first to prove the existence and uniqueness of geodesic loop restricted on a closed face sequence; it contributes also with an efficient algorithm to iteratively evolve an initial closed path on a given mesh into an exact geodesic loop within finite steps. Our proposed algorithm takes only an O(k) space complexity and an O(mk) time complexity (experimentally), where m is the number of vertices in the region bounded by the initial loop and the resultant geodesic loop, and k is the average number of edges in the edge sequences that the evolving loop passes through. In contrast to the existing geodesic curvature flow methods which compute an approximate geodesic loop within a predefined threshold, our method is exact and can apply directly to triangular meshes without needing to solve any differential equation with a numerical solver; it can run at interactive speed, e.g., in the order of milliseconds, for a mesh with around 50K vertices, and hence, significantly outperforms existing algorithms. Actually, our algorithm could run at interactive speed even for larger meshes. Besides the complexity of the input mesh, the geometric shape could also affect the number of evolving steps, i.e., the performance. We motivate our algorithm with an interactive shape segmentation example shown later in the paper.
Liao, Yuying; Mo, Guodong; Sun, Junli; Wei, Fengying; Liao, Dezhong Joshua
2016-05-01
The domestic chicken (Gallus gallus domesticus) is an excellent model for genetic studies of phenotypic diversity. The Guangxi Region of China possesses several native chicken breeds displaying a broad range of phenotypes well adapted to the extreme hot-and-wet environments in the region. We thus evaluated the genetic diversity and relationships among six native chicken populations of the Guangxi region and also evaluated two commercial breeds (Arbor Acres and Roman chickens). We analyzed the sequences of the D-loop region of the mitochondrial DNA (mtDNA) and 18 microsatellite loci of 280 blood samples from six Guangxi native chicken breeds and from Arbor Acres and Roman chickens, and used the neighbor-joining method to construct the phylogenetic tree of these eight breeds. Our results showed that the genetic diversity of Guangxi native breeds was relatively rich. The phylogenetic tree using the unweighed pair-group method with arithmetic means (UPGAM) on microsatellite marks revealed two main clusters. Arbor Acres chicken and Roman chicken were in one cluster, while the Guangxi breeds were in the other cluster. Moreover, the UPGAM tree of Guangxi native breeds based on microsatellite loci was more consistent with the genesis, breeding history, differentiation and location than the mtDNA D-loop region. STRUCTURE analysis further confirmed the genetic structure of Guangxi native breeds in the Neighbor-Net dendrogram. The nomenclature of mtDNA sequence polymorphisms suggests that the Guangxi native chickens are distributed across four clades, but most of them are clustered in two main clades (B and E), with the other haplotypes within the clades A and C. The Guangxi native breeds revealed abundant genetic diversity not only on microsatellite loci but also on mtDNA D-loop region, and contained multiple maternal lineages, including one from China and another from Europe or the Middle East.
Experimental evidence for circular inference in schizophrenia
Jardri, Renaud; Duverne, Sandrine; Litvinova, Alexandra S; Denève, Sophie
2017-01-01
Schizophrenia (SCZ) is a complex mental disorder that may result in some combination of hallucinations, delusions and disorganized thinking. Here SCZ patients and healthy controls (CTLs) report their level of confidence on a forced-choice task that manipulated the strength of sensory evidence and prior information. Neither group's responses can be explained by simple Bayesian inference. Rather, individual responses are best captured by a model with different degrees of circular inference. Circular inference refers to a corruption of sensory data by prior information and vice versa, leading us to ‘see what we expect' (through descending loops), to ‘expect what we see' (through ascending loops) or both. Ascending loops are stronger for SCZ than CTLs and correlate with the severity of positive symptoms. Descending loops correlate with the severity of negative symptoms. Both loops correlate with disorganized symptoms. The findings suggest that circular inference might mediate the clinical manifestations of SCZ. PMID:28139642
Experimental evidence for circular inference in schizophrenia.
Jardri, Renaud; Duverne, Sandrine; Litvinova, Alexandra S; Denève, Sophie
2017-01-31
Schizophrenia (SCZ) is a complex mental disorder that may result in some combination of hallucinations, delusions and disorganized thinking. Here SCZ patients and healthy controls (CTLs) report their level of confidence on a forced-choice task that manipulated the strength of sensory evidence and prior information. Neither group's responses can be explained by simple Bayesian inference. Rather, individual responses are best captured by a model with different degrees of circular inference. Circular inference refers to a corruption of sensory data by prior information and vice versa, leading us to 'see what we expect' (through descending loops), to 'expect what we see' (through ascending loops) or both. Ascending loops are stronger for SCZ than CTLs and correlate with the severity of positive symptoms. Descending loops correlate with the severity of negative symptoms. Both loops correlate with disorganized symptoms. The findings suggest that circular inference might mediate the clinical manifestations of SCZ.
Experimental evidence for circular inference in schizophrenia
NASA Astrophysics Data System (ADS)
Jardri, Renaud; Duverne, Sandrine; Litvinova, Alexandra S.; Denève, Sophie
2017-01-01
Schizophrenia (SCZ) is a complex mental disorder that may result in some combination of hallucinations, delusions and disorganized thinking. Here SCZ patients and healthy controls (CTLs) report their level of confidence on a forced-choice task that manipulated the strength of sensory evidence and prior information. Neither group's responses can be explained by simple Bayesian inference. Rather, individual responses are best captured by a model with different degrees of circular inference. Circular inference refers to a corruption of sensory data by prior information and vice versa, leading us to `see what we expect' (through descending loops), to `expect what we see' (through ascending loops) or both. Ascending loops are stronger for SCZ than CTLs and correlate with the severity of positive symptoms. Descending loops correlate with the severity of negative symptoms. Both loops correlate with disorganized symptoms. The findings suggest that circular inference might mediate the clinical manifestations of SCZ.
Prevalence and Length of the Anterior Loop of the Inferior Alveolar Nerve in Iranians.
Moghddam, Maryam Rastegar; Davoudmanesh, Zeinab; Azizi, Nasim; Rakhshan, Vahid; Shariati, Mahsa
2017-10-01
The anterior loop of the inferior alveolar nerve is a sensitive anatomical feature that should be taken into account during installation of dental implants anterior to the mental foramen. This study was conducted to explore the controversy regarding prevalence and length. A total of 452 mandible quadrants of 234 patients (age: 50.1 ± 13.3 years, 113 males, 121 females) were studied using cone-beam computerized tomography. After reconstructing axial, frontal, and sagittal slices, the region between the most anterior point on the mental foramen and the most anterior part of the mandibular nerve was inspected for signs of anterior loop presence. If positive, the length of the anterior loop was measured in mm as the distance between the anterior border of mental foramen and the anterior border of the loop. Prevalence and length of the anterior loop were compared statistically between sexes and age groups. The anterior loop was observed in 106 quadrants (23.5% of 451 quadrants) of 95 patients (40.6% of 234 patients), of whom 11 had bilateral anterior loops. Prevalences were similar in males (41%) and females (39%, chi-square P =.791). The mean anterior loop length was 2.77 ± 1.56 mm (95% CI: 2.5-3.1 mm), without significant sex (regression beta = -0.159, P = .134) or age (beta = -0.059, P = .578) differences. The anterior loop might exist in about 40% of patients, regardless of their gender. The mean safe anterior distance from the anterior loop is about 3 mm + (2.5-3.1 mm) = 5.5-6.1 mm, regardless of age.
Thermal Vacuum Testing of a Helium Loop Heat Pipe for Large Area Cryocooling
NASA Technical Reports Server (NTRS)
Ku, Jentung; Robinson, Franklin
2016-01-01
A loop heat pipe must start successfully before it can commence its service. The startup transient represents one of the most complex phenomena in the loop heat pipe operation. This paper discusses various aspects of loop heat pipe startup behaviors. Topics include the four startup scenarios, the initial fluid distribution between the evaporator and reservoir that determines the startup scenario, factors that affect the fluid distribution between the evaporator and reservoir, difficulties encountered during the low power startup, and methods to enhance the startup success. Also addressed are the pressure spike and pressure surge during the startup transient, and repeated cycles of loop startup and shutdown under certain conditions.
Decay-less kink oscillations in coronal loops
NASA Astrophysics Data System (ADS)
Anfinogentov, S.; Nisticò, G.; Nakariakov, V. M.
2013-12-01
Context. Kink oscillations of coronal loops in an off-limb active region are detected with the Imaging Assembly Array (AIA) instruments of the Solar Dynamics Observatory (SDO) at 171 Å. Aims: We aim to measure periods and amplitudes of kink oscillations of different loops and to determinate the evolution of the oscillation phase along the oscillating loop. Methods: Oscillating coronal loops were visually identified in the field of view of SDO/AIA and STEREO/EUVI-A: the loop length was derived by three-dimensional analysis. Several slits were taken along the loops to assemble time-distance maps. We identified oscillatory patterns and retrieved periods and amplitudes of the oscillations. We applied the cross-correlation technique to estimate the phase shift between oscillations at different segments of oscillating loops. Results: We found that all analysed loops show low-amplitude undamped transverse oscillations. Oscillation periods of loops in the same active region range from 2.5 to 11 min, and are different for different loops. The displacement amplitude is lower than 1 Mm. The oscillation phase is constant along each analysed loop. The spatial structure of the phase of the oscillations corresponds to the fundamental standing kink mode. We conclude that the observed behaviour is consistent with the empirical model in terms of a damped harmonic resonator affected by a non-resonant continuously operating external force. A movie is available in electronic form at http://www.aanda.org
Circuitry, systems and methods for detecting magnetic fields
Kotter, Dale K [Shelley, ID; Spencer, David F [Idaho Falls, ID; Roybal, Lyle G [Idaho Falls, ID; Rohrbaugh, David T [Idaho Falls, ID
2010-09-14
Circuitry for detecting magnetic fields includes a first magnetoresistive sensor and a second magnetoresistive sensor configured to form a gradiometer. The circuitry includes a digital signal processor and a first feedback loop coupled between the first magnetoresistive sensor and the digital signal processor. A second feedback loop which is discrete from the first feedback loop is coupled between the second magnetoresistive sensor and the digital signal processor.
Reducing full one-loop amplitudes to scalar integrals at the integrand level
NASA Astrophysics Data System (ADS)
Ossola, Giovanni; Papadopoulos, Costas G.; Pittau, Roberto
2007-02-01
We show how to extract the coefficients of the 4-, 3-, 2- and 1-point one-loop scalar integrals from the full one-loop amplitude of arbitrary scattering processes. In a similar fashion, also the rational terms can be derived. Basically no information on the analytical structure of the amplitude is required, making our method appealing for an efficient numerical implementation.
Metrics for Systems Thinking in the Human Dimension
2016-11-01
corpora of documents. 2 Methodology Overview We present a human-in-the- loop methodology that assists researchers and analysts by characterizing...supervised learning methods. Building on this foundation, we present an unsupervised, human-in-the- loop methodology that utilizes topic models to...the definition of strong systems thinking and in the interpretation of topics, but this is what makes the human-in-the- loop methodology so effective
Nucleic acid detection methods
Smith, C.L.; Yaar, R.; Szafranski, P.; Cantor, C.R.
1998-05-19
The invention relates to methods for rapidly determining the sequence and/or length a target sequence. The target sequence may be a series of known or unknown repeat sequences which are hybridized to an array of probes. The hybridized array is digested with a single-strand nuclease and free 3{prime}-hydroxyl groups extended with a nucleic acid polymerase. Nuclease cleaved heteroduplexes can be easily distinguish from nuclease uncleaved heteroduplexes by differential labeling. Probes and target can be differentially labeled with detectable labels. Matched target can be detected by cleaving resulting loops from the hybridized target and creating free 3-hydroxyl groups. These groups are recognized and extended by polymerases added into the reaction system which also adds or releases one label into solution. Analysis of the resulting products using either solid phase or solution. These methods can be used to detect characteristic nucleic acid sequences, to determine target sequence and to screen for genetic defects and disorders. Assays can be conducted on solid surfaces allowing for multiple reactions to be conducted in parallel and, if desired, automated. 18 figs.
Constructive tensorial group field theory II: the {U(1)-T^4_4} model
NASA Astrophysics Data System (ADS)
Lahoche, Vincent
2018-05-01
In this paper, we continue our program of non-pertubative constructions of tensorial group field theories (TGFT). We prove analyticity and Borel summability in a suitable domain of the coupling constant of the simplest super-renormalizable TGFT which contains some ultraviolet divergencies, namely the color-symmetric quartic melonic rank-four model with Abelian gauge invariance, nicknamed . We use a multiscale loop vertex expansion. It is an extension of the loop vertex expansion (the basic constructive technique for non-local theories) which is required for theories that involve non-trivial renormalization.
Accumulation of dislocation loops in the α phase of Zr Excel alloy under heavy ion irradiation
NASA Astrophysics Data System (ADS)
Yu, Hongbing; Yao, Zhongwen; Idrees, Yasir; Zhang, He K.; Kirk, Mark A.; Daymond, Mark R.
2017-08-01
In-situ heavy ion irradiations were performed on the high Sn content Zr alloy 'Excel', measuring type dislocation loop accumulation up to irradiation damage doses of 10 dpa at a range of temperatures. The high content of Sn, which diffuses slowly, and the thin foil geometry of the sample provide a unique opportunity to study an extreme case where displacement cascades dominate the loop formation and evolution. The dynamic observation of dislocation loop evolution under irradiation at 200 °C reveals that type dislocation loops can form at very low dose (0.0025 dpa). The size of the dislocation loops increases slightly with irradiation damage dose. The mechanism controlling loop growth in this study is different from that in neutron irradiation; in this study, larger dislocation loops can condense directly from the interaction of displacement cascades and the high concentration of point defects in the matrix. The size of the dislocation loop is dependent on the point defect concentration in the matrix. A negative correlation between the irradiation temperature and the dislocation loop size was observed. A comparison between cascade dominated loop evolution (this study), diffusion dominated loop evolution (electron irradiation) and neutron irradiation suggests that heavy ion irradiation alone may not be enough to accurately reproduce neutron irradiation induced loop structures. An alternative method is proposed in this paper. The effects of Sn on the displacement cascades, defect yield, and the diffusion behavior of point defects are established.
Okubo, Hirotaka; Kusano, Nozomu; Kinjo, Masaki; Kanaya, Fuminori
2015-01-01
In multi-strand suture methods consisting of several suture rows, the different length of core suture purchase between each suture row may affect the strength of repairs. We evaluated the influence of the different length of core suture purchase between each suture row on the strength of 6-strand tendon repairs. Rabbit flexor tendons were repaired by using a triple-looped suture technique in which the suture purchase length in each suture row was modified. Group 1, all lengths are 8-mm. Group 2, all lengths are 10-mm. Group 3, two are 10-mm and one is 8-mm. Group 4, one is 10-mm and two are 8-mm. The repaired tendons were subjected to load-to-failure test. The gap strength was significantly greater in Group 1 and Group 2 than in Group 3 and Group 4. This study demonstrates that maintaining equal core suture purchase lengths of each suture row increases the gap resistance.
Breaking a habit: a further role of the phonological loop in action control.
Saeki, Erina; Baddeley, Alan D; Hitch, Graham J; Saito, Satoru
2013-10-01
Recent research has suggested that keeping track of a task goal in rapid task switching may depend on the phonological loop component of working memory. In this study, we investigated whether the phonological loop plays a similar role when a single switch extending over several trials is required after many trials on which one has performed a competing task. Participants were shown pairs of digits varying in numerical and physical size, and they were required to decide which digit was numerically or physically larger. An experimental cycle consisted of four blocks of 24 trials. In Experiment 1, participants in the task change groups performed the numerical-size judgment task during the first three blocks, and then changed to the physical-size judgment task in the fourth. Participants in the continuation groups performed only the physical-size judgment task throughout all four blocks. We found negative effects of articulatory suppression on the fourth block, but only in the task change groups. Experiment 2 was a replication, with the modification that both groups received identical instructions and practice. Experiment 3 was a further replication using numerical-size judgment as the target task. The results showed a pattern similar to that from Experiment 1, with negative effects of articulatory suppression found only in the task change group. The congruity of numerical and physical size had a reliable effect on performance in all three experiments, but unlike the task change, it did not reliably interact with articulatory suppression. The results suggest that in addition to its well-established role in rapid task switching, the phonological loop also contributes to active goal maintenance in longer-term action control.
Closed-loop endo-atmospheric ascent guidance for reusable launch vehicle
NASA Astrophysics Data System (ADS)
Sun, Hongsheng
This dissertation focuses on the development of a closed-loop endo-atmospheric ascent guidance algorithm for the 2nd generation reusable launch vehicle. Special attention has been given to the issues that impact on viability, complexity and reliability in on-board implementation. The algorithm is called once every guidance update cycle to recalculate the optimal solution based on the current flight condition, taking into account atmospheric effects and path constraints. This is different from traditional ascent guidance algorithms which operate in a simple open-loop mode inside atmosphere, and later switch to a closed-loop vacuum ascent guidance scheme. The classical finite difference method is shown to be well suited for fast solution of the constrained optimal three-dimensional ascent problem. The initial guesses for the solutions are generated using an analytical vacuum optimal ascent guidance algorithm. Homotopy method is employed to gradually introduce the aerodynamic forces to generate the optimal solution from the optimal vacuum solution. The vehicle chosen for this study is the Lockheed Martin X-33 lifting-body reusable launch vehicle. To verify the algorithm presented in this dissertation, a series of open-loop and closed-loop tests are performed for three different missions. Wind effects are also studied in the closed-loop simulations. For comparison, the solutions for the same missions are also obtained by two independent optimization softwares. The results clearly establish the feasibility of closed-loop endo-atmospheric ascent guidance of rocket-powered launch vehicles. ATO cases are also tested to assess the adaptability of the algorithm to autonomously incorporate the abort modes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Yanfei; Larson, Ben C.
There are large classes of materials problems that involve the solutions of stress, displacement, and strain energy of dislocation loops in elastically anisotropic solids, including increasingly detailed investigations of the generation and evolution of irradiation induced defect clusters ranging in sizes from the micro- to meso-scopic length scales. Based on a two-dimensional Fourier transform and Stroh formalism that are ideal for homogeneous and layered anisotropic solids, we have developed robust and computationally efficient methods to calculate the displacement fields for circular and polygonal dislocation loops. Using the homogeneous nature of the Green tensor of order -1, we have shown thatmore » the displacement and stress fields of dislocation loops can be obtained by numerical quadrature of a line integral. In addition, it is shown that the sextuple integrals associated with the strain energy of loops can be represented by the product of a pre-factor containing elastic anisotropy effects and a universal term that is singular and equal to that for elastic isotropic case. Furthermore, we have found that the self-energy pre-factor of prismatic loops is identical to the effective modulus of normal contact, and the pre-factor of shear loops differs from the effective indentation modulus in shear by only a few percent. These results provide a convenient method for examining dislocation reaction energetic and efficient procedures for numerical computation of local displacements and stresses of dislocation loops, both of which play integral roles in quantitative defect analyses within combined experimental–theoretical investigations.« less
Gao, Yanfei; Larson, Ben C.
2015-06-19
There are large classes of materials problems that involve the solutions of stress, displacement, and strain energy of dislocation loops in elastically anisotropic solids, including increasingly detailed investigations of the generation and evolution of irradiation induced defect clusters ranging in sizes from the micro- to meso-scopic length scales. Based on a two-dimensional Fourier transform and Stroh formalism that are ideal for homogeneous and layered anisotropic solids, we have developed robust and computationally efficient methods to calculate the displacement fields for circular and polygonal dislocation loops. Using the homogeneous nature of the Green tensor of order -1, we have shown thatmore » the displacement and stress fields of dislocation loops can be obtained by numerical quadrature of a line integral. In addition, it is shown that the sextuple integrals associated with the strain energy of loops can be represented by the product of a pre-factor containing elastic anisotropy effects and a universal term that is singular and equal to that for elastic isotropic case. Furthermore, we have found that the self-energy pre-factor of prismatic loops is identical to the effective modulus of normal contact, and the pre-factor of shear loops differs from the effective indentation modulus in shear by only a few percent. These results provide a convenient method for examining dislocation reaction energetic and efficient procedures for numerical computation of local displacements and stresses of dislocation loops, both of which play integral roles in quantitative defect analyses within combined experimental–theoretical investigations.« less
Yokota, Takehiro; Nara, Yukinori; Kashima, Akiko; Matsubara, Keiko; Misawa, Satoru; Kato, Ryohei; Sugio, Shigetoshi
2007-02-01
Human JNK stimulatory phosphatase-1 (JSP-1) is a novel member of dual specificity phosphatases. A C-terminus truncated JSP-1 was expressed in Escherichia coli and was crystallized using the sitting-drop vapor diffusion method. Thin-plate crystals obtained at 278 K belong to a monoclinic space group, C2, with unit-cell parameters a = 84.0 A, b = 49.3 A, c = 47.3 A, and beta = 119.5 degrees , and diffract up to 1.5 A resolution at 100 K. The structure of JSP-1 has a single compact (alpha/beta) domain, which consists of six alpha-helices and five beta-strands, and shows a conserved structural scaffold in regard to both DSPs and PTPs. A cleft formed by a PTP-loop at the active site is very shallow, and is occupied by one sulfonate compound, MES, at the bottom. In the binary complex structure of JSP-1 with MES, the conformations of three important segments in regard to the catalytic mechanism are not similar to those in PTP1B. JSP-1 has no loop corresponding to the Lys120-loop of PTP1B, and tryptophan residue corresponding to the substrate-stacking in PTP1B is substituted by alanine residue in JSP-1. Copyright 2006 Wiley-Liss, Inc.
N -loop running should be combined with N -loop matching
NASA Astrophysics Data System (ADS)
Braathen, Johannes; Goodsell, Mark D.; Krauss, Manuel E.; Opferkuch, Toby; Staub, Florian
2018-01-01
We investigate the high-scale behavior of Higgs sectors beyond the Standard Model, pointing out that the proper matching of the quartic couplings before applying the renormalization group equations (RGEs) is of crucial importance for reliable predictions at larger energy scales. In particular, the common practice of leading-order parameters in the RGE evolution is insufficient to make precise statements on a given model's UV behavior, typically resulting in uncertainties of many orders of magnitude. We argue that, before applying N -loop RGEs, a matching should even be performed at N -loop order in contrast to common lore. We show both analytical and numerical results where the impact is sizable for three minimal extensions of the Standard Model: a singlet extension, a second Higgs doublet and finally vector-like quarks. We highlight that the known two-loop RGEs tend to moderate the running of their one-loop counterparts, typically delaying the appearance of Landau poles. For the addition of vector-like quarks we show that the complete two-loop matching and RGE evolution hints at a stabilization of the electroweak vacuum at high energies, in contrast to results in the literature.
Closed-loop and robust control of quantum systems.
Chen, Chunlin; Wang, Lin-Cheng; Wang, Yuanlong
2013-01-01
For most practical quantum control systems, it is important and difficult to attain robustness and reliability due to unavoidable uncertainties in the system dynamics or models. Three kinds of typical approaches (e.g., closed-loop learning control, feedback control, and robust control) have been proved to be effective to solve these problems. This work presents a self-contained survey on the closed-loop and robust control of quantum systems, as well as a brief introduction to a selection of basic theories and methods in this research area, to provide interested readers with a general idea for further studies. In the area of closed-loop learning control of quantum systems, we survey and introduce such learning control methods as gradient-based methods, genetic algorithms (GA), and reinforcement learning (RL) methods from a unified point of view of exploring the quantum control landscapes. For the feedback control approach, the paper surveys three control strategies including Lyapunov control, measurement-based control, and coherent-feedback control. Then such topics in the field of quantum robust control as H(∞) control, sliding mode control, quantum risk-sensitive control, and quantum ensemble control are reviewed. The paper concludes with a perspective of future research directions that are likely to attract more attention.
NLO cross sections in 4 dimensions without DREG
NASA Astrophysics Data System (ADS)
Hernández-Pinto, R. J.; Driencourt-Mangin, F.; Rodrigo, G.; Sborlini, G. F. R.
2016-10-01
In this review, we present a new method for computing physical cross sections at NLO accuracy in QCD without using the standard Dimensional Regularisation. The algorithm is based on the Loop-Tree Duality theorem, which allow us to obtain loop integrals as a sum of phase-space integrals; in this way, transforming loop integrals into phase-space integrals, we propose a method to merge virtual and real contributions in order to find observables at NLO in d = 4 space-time dimensions. In addition, the strategy described is used for computing the γ* → qq̅(g) process. A more detailed discussion related on this topic can be found in Ref [1].
Method and device for measuring single-shot transient signals
Yin, Yan
2004-05-18
Methods, apparatus, and systems, including computer program products, implementing and using techniques for measuring multi-channel single-shot transient signals. A signal acquisition unit receives one or more single-shot pulses from a multi-channel source. An optical-fiber recirculating loop reproduces the one or more received single-shot optical pulses to form a first multi-channel pulse train for circulation in the recirculating loop, and a second multi-channel pulse train for display on a display device. The optical-fiber recirculating loop also optically amplifies the first circulating pulse train to compensate for signal losses and performs optical multi-channel noise filtration.
Loop versus end colostomy reversal: has anything changed?
Bruns, B R; DuBose, J; Pasley, J; Kheirbek, T; Chouliaras, K; Riggle, A; Frank, M K; Phelan, H A; Holena, D; Inaba, K; Diaz, J; Scalea, T M
2015-10-01
Though primary repair of colon injuries is preferred, certain injury patterns require colostomy creation. Colostomy reversal is associated with significant morbidity and healthcare cost. Complication rates may be influenced by technique of diversion (loop vs. end colostomy), though this remains ill-defined. We hypothesized that reversal of loop colostomies is associated with fewer complications than end colostomies. This is a retrospective, multi-institutional study (four, level-1 trauma centers) of patients undergoing colostomy takedown for trauma during the time period 1/2006-12/2012. Data were collected from index trauma admission and subsequent admission for reversal and included demographics and complications of reversal. Student's t test was used to compare continuous variables against loop versus end colostomy. Discrete variables were compared against both groups using Chi-squared tests. Over the 6-year study period, 218 patients underwent colostomy takedown after trauma with a mean age of 30; 190 (87%) were male, 162 (74%) had penetrating injury as their indication for colostomy, and 98 (45%) experienced at least one complication. Patients in the end colostomy group (n = 160) were more likely to require midline laparotomy (145 vs. 18, p < 0.001), had greater intra-operative blood loss (260.7 vs. 99.4 mL, p < 0.001), had greater hospital length of stay (8.4 vs. 5.5 days, p < 0.001), and had more overall complications (81 vs. 17, p = 0.005) than patients managed with loop colostomy (n = 58). Local takedown of a loop colostomy is safe and leads to shorter hospital stays, less intra-operative blood loss, and fewer complications when compared to end colostomy.
Mizuno, Kentaro; Mikami, Yasuo; Hase, Hitoshi; Ikeda, Takumi; Nagae, Masateru; Tonomura, Hitoshi; Shirai, Toshiharu; Fujiwara, Hiroyoshi; Kubo, Toshikazu
2017-02-01
A technical note and retrospective study. The objectives were to describe a new method of drainage tube placement during microendoscopic spinal decompression, and compare the positioning and fluid discharge obtained with this method and the conventional method. To prevent postoperative epidural hematoma after microendoscopic decompression, a drainage tube must be placed in a suitable location. However, the narrow operative field makes precise control of the position of the tube technically difficult. We developed a method to reliably place the tube in the desired location. We use a Deschamps aneurysm needle with a slightly curved tip, which we call a drain passer. With the microendoscope in position, the drain passer, with a silk thread passed through the eye at the needle tip, is inserted percutaneously into the endoscopic field of view. The drainage tube is passed through the loop of silk thread protruding from the inside of the tubular retractor, and the thread is pulled to the outside, guiding the end of the drainage tube into the wound. This method was used in 23 cases at 44 intervertebral levels (drain passer group), and the conventional method in 20 cases at 32 intervertebral levels (conventional group). Postoperative plain radiographs were taken, and the amount of fluid discharge at postoperative hour 24 was measured. Drainage tube positioning was favorable at 43 intervertebral levels (97.7%) in the drain passer group and 26 intervertebral levels (81.3%) in the conventional group. Mean fluid discharge was 58.4±32.2 g in the drain passer group and 38.4±23.0 g in the conventional group. Positioning was significantly better and fluid discharge was significantly greater in the drain passer group. The results indicate that this method is a useful drainage tube placement technique for preventing postoperative epidural hematoma.
Method for distributed agent-based non-expert simulation of manufacturing process behavior
Ivezic, Nenad; Potok, Thomas E.
2004-11-30
A method for distributed agent based non-expert simulation of manufacturing process behavior on a single-processor computer comprises the steps of: object modeling a manufacturing technique having a plurality of processes; associating a distributed agent with each the process; and, programming each the agent to respond to discrete events corresponding to the manufacturing technique, wherein each discrete event triggers a programmed response. The method can further comprise the step of transmitting the discrete events to each agent in a message loop. In addition, the programming step comprises the step of conditioning each agent to respond to a discrete event selected from the group consisting of a clock tick message, a resources received message, and a request for output production message.
Viviani, Vadim R; Silva Neto, Antonio J; Arnoldi, Frederico G C; Barbosa, João A R G; Ohmiya, Yoshihiro
2008-01-01
Beetle luciferases emit a wide range of bioluminescence colors, ranging from green to red. Firefly luciferases can shift the spectrum to red in response to pH and temperature changes, whereas click beetle and railroadworm luciferases do not. Despite many studies on firefly luciferases, the origin of pH-sensitivity is far from being understood. Through comparative site-directed mutagenesis and modeling studies, using the pH-sensitive luciferases (Macrolampis and Cratomorphus distinctus fireflies) and the pH-insensitive luciferases (Pyrearinus termitilluminans, Phrixotrix viviani and Phrixotrix hirtus) cloned by our group, here we show that substitutions dramatically affecting bioluminescence colors in both groups of luciferases are clustered in the loop between residues 223-235 (Photinus pyralis sequence). The substitutions at positions 227, 228 and 229 (P. pyralis sequence) cause dramatic redshift and temporal shift in both groups of luciferases, indicating their involvement in labile interactions. Modeling studies showed that the residues Y227 and N229 are buried in the protein core, fixing the loop to other structural elements participating at the bottom of the luciferin binding site. Changes in pH and temperature (in firefly luciferases), as well as point mutations in this loop, may disrupt the interactions of these structural elements exposing the active site and modulating bioluminescence colors.
Assessment of Snared-Loop Technique When Standard Retrieval of Inferior Vena Cava Filters Fails
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doody, Orla, E-mail: orla_doody@hotmail.com; Noe, Geertje; Given, Mark F.
Purpose To identify the success and complications related to a variant technique used to retrieve inferior vena cava filters when simple snare approach has failed. Methods A retrospective review of all Cook Guenther Tulip filters and Cook Celect filters retrieved between July 2006 and February 2008 was performed. During this period, 130 filter retrievals were attempted. In 33 cases, the standard retrieval technique failed. Retrieval was subsequently attempted with our modified retrieval technique. Results The retrieval was successful in 23 cases (mean dwell time, 171.84 days; range, 5-505 days) and unsuccessful in 10 cases (mean dwell time, 162.2 days; range,more » 94-360 days). Our filter retrievability rates increased from 74.6% with the standard retrieval method to 92.3% when the snared-loop technique was used. Unsuccessful retrieval was due to significant endothelialization (n = 9) and caval penetration by the filter (n = 1). A single complication occurred in the group, in a patient developing pulmonary emboli after attempted retrieval. Conclusion The technique we describe increased the retrievability of the two filters studied. Hook endothelialization is the main factor resulting in failed retrieval and continues to be a limitation with these filters.« less
Taylor, Katherine L; Parshuram, Christopher S; Ferri, Susan; Mema, Briseida
2017-06-01
Communication during resuscitation is essential for the provision of coordinated, effective care. Previously, we observed 44% of resuscitation communication originated from participants other than the physician team leader; 65% of which was directed to the team, exclusive of the team leader. We called this outer-loop communication. This institutional review board-approved qualitative study used grounded theory analysis of focus groups and interviews to describe and define outer-loop communication and the role of "event manager" as an additional "leader." Participants were health care staff involved in the medical management of resuscitations in a quaternary pediatric academic hospital. The following 3 domains were identified: the existence and rationale of outer-loop communication; the functions fulfilled by outer-loop communication; and the leadership and learning of event manager skills. The role was recognized by all team members and evolved organically as resuscitation complexity increased. A "good" manager has similar qualities to a "good team leader" with strong nontechnical skills. Event managers were not formally identified and no specific training had occurred. "Outer-loop" communication supports resuscitation activities. An event manager gives direction to the team, coordinates activities, and supports the team leader. We describe a new role in resuscitation in light of structural organizational theory and cognitive load with a view to incorporating this structure into resuscitation training. Copyright © 2017 Elsevier Inc. All rights reserved.
Detection of endoscopic looping during colonoscopy procedure by using embedded bending sensors
Bruce, Michael; Choi, JungHun
2018-01-01
Background Looping of the colonoscope shaft during procedure is one of the most common obstacles encountered by colonoscopists. It occurs in 91% of cases with the N-sigmoid loop being the most common, occurring in 79% of cases. Purpose Herein, a novel system is developed that will give a complete three-dimensional (3D) vector image of the shaft as it passes through the colon, to aid the colonoscopist in detecting loops before they form. Patients and methods A series of connected links spans the middle 50% of the shaft, where loops are likely to form. Two potentiometers are attached at each joint to measure angular deflection in two directions to allow for 3D positioning. This 3D positioning is converted into a 3D vector image using computer software. MATLAB software has been used to display the image on a computer monitor. For the different configuration of the colon model, the system determined the looping status. Results Different configurations (N loop, reverse gamma loop, and reverse splenic flexure) of the loops were well defined using 3D vector image. Conclusion The novel sensory system can accurately define the various configuration of the colon during the colonoscopy procedure. PMID:29849469
Golebiowski, Jérôme; Antonczak, Serge; Fernandez-Carmona, Juan; Condom, Roger; Cabrol-Bass, Daniel
2004-12-01
Nanosecond molecular dynamics using the Ewald summation method have been performed to elucidate the structural and energetic role of the closing base pair in loop-loop RNA duplexes neutralized by Mg2+ counterions in aqueous phases. Mismatches GA, CU and Watson-Crick GC base pairs have been considered for closing the loop of an RNA in complementary interaction with HIV-1 TAR. The simulations reveal that the mismatch GA base, mediated by a water molecule, leads to a complex that presents the best compromise between flexibility and energetic contributions. The mismatch CU base pair, in spite of the presence of an inserted water molecule, is too short to achieve a tight interaction at the closing-loop junction and seems to force TAR to reorganize upon binding. An energetic analysis has allowed us to quantify the strength of the interactions of the closing and the loop-loop pairs throughout the simulations. Although the water-mediated GA closing base pair presents an interaction energy similar to that found on fully geometry-optimized structure, the water-mediated CU closing base pair energy interaction reaches less than half the optimal value.
Blooming Knit Flowers: Loop-Linked Soft Morphing Structures for Soft Robotics.
Han, Min-Woo; Ahn, Sung-Hoon
2017-04-01
A loop-linked structure, which is capable of morphing in various modes, including volumetric transformation, is developed based on knitting methods. Morphing flowers (a lily-like, a daffodil-like, gamopetalous, and a calla-like flower) are fabricated using loop patterning, and their blooming motion is demonstrated by controlling a current that selectively actuates the flowers petals. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A 3T Sodium and Proton Composite Array Breast Coil
Kaggie, Joshua D.; Hadley, J. Rock; Badal, James; Campbell, John R.; Park, Daniel J.; Parker, Dennis L.; Morrell, Glen; Newbould, Rexford D.; Wood, Ali F.; Bangerter, Neal K.
2013-01-01
Purpose The objective of this study was to determine whether a sodium phased array would improve sodium breast MRI at 3T. The secondary objective was to create acceptable proton images with the sodium phased array in place. Methods A novel composite array for combined proton/sodium 3T breast MRI is compared to a coil with a single proton and sodium channel. The composite array consists of a 7-channel sodium receive array, a larger sodium transmit coil, and a 4-channel proton transceive array. The new composite array design utilizes smaller sodium receive loops than typically used in sodium imaging, uses novel decoupling methods between the receive loops and transmit loops, and uses a novel multi-channel proton transceive coil. The proton transceive coil reduces coupling between proton and sodium elements by intersecting the constituent loops to reduce their mutual inductance. The coil used for comparison consists of a concentric sodium and proton loop with passive decoupling traps. Results The composite array coil demonstrates a 2–5x improvement in SNR for sodium imaging and similar SNR for proton imaging when compared to a simple single-loop dual resonant design. Conclusion The improved SNR of the composite array gives breast sodium images of unprecedented quality in reasonable scan times. PMID:24105740
Tweaking one-loop determinants in AdS3
NASA Astrophysics Data System (ADS)
Castro, Alejandra; Keeler, Cynthia; Szepietowski, Phillip
2017-10-01
We revisit the subject of one-loop determinants in AdS3 gravity via the quasi-normal mode method. Our goal is to evaluate a one-loop determinant with chiral boundary conditions for the metric field; chirality is achieved by imposing Dirichlet boundary conditions on certain components while others satisfy Neumann. Along the way, we give a generalization of the quasinormal mode method for stationary (non-static) thermal backgrounds, and propose a treatment for Neumann boundary conditions in this framework. We evaluate the graviton one-loop determinant on the Euclidean BTZ background with parity-violating boundary conditions (CSS), and find excellent agreement with the dual warped CFT. We also discuss a more general falloff in AdS3 that is related to two dimensional quantum gravity in lightcone gauge. The behavior of the ghost fields under both sets of boundary conditions is novel and we discuss potential interpretations.
Multi-mode ultrasonic welding control and optimization
Tang, Jason C.H.; Cai, Wayne W
2013-05-28
A system and method for providing multi-mode control of an ultrasonic welding system. In one embodiment, the control modes include the energy of the weld, the time of the welding process and the compression displacement of the parts being welded during the welding process. The method includes providing thresholds for each of the modes, and terminating the welding process after the threshold for each mode has been reached, the threshold for more than one mode has been reached or the threshold for one of the modes has been reached. The welding control can be either open-loop or closed-loop, where the open-loop process provides the mode thresholds and once one or more of those thresholds is reached the welding process is terminated. The closed-loop control provides feedback of the weld energy and/or the compression displacement so that the weld power and/or weld pressure can be increased or decreased accordingly.
Methods and systems for the production of hydrogen
Oh, Chang H [Idaho Falls, ID; Kim, Eung S [Ammon, ID; Sherman, Steven R [Augusta, GA
2012-03-13
Methods and systems are disclosed for the production of hydrogen and the use of high-temperature heat sources in energy conversion. In one embodiment, a primary loop may include a nuclear reactor utilizing a molten salt or helium as a coolant. The nuclear reactor may provide heat energy to a power generation loop for production of electrical energy. For example, a supercritical carbon dioxide fluid may be heated by the nuclear reactor via the molten salt and then expanded in a turbine to drive a generator. An intermediate heat exchange loop may also be thermally coupled with the primary loop and provide heat energy to one or more hydrogen production facilities. A portion of the hydrogen produced by the hydrogen production facility may be diverted to a combustor to elevate the temperature of water being split into hydrogen and oxygen by the hydrogen production facility.
Robust fast controller design via nonlinear fractional differential equations.
Zhou, Xi; Wei, Yiheng; Liang, Shu; Wang, Yong
2017-07-01
A new method for linear system controller design is proposed whereby the closed-loop system achieves both robustness and fast response. The robustness performance considered here means the damping ratio of closed-loop system can keep its desired value under system parameter perturbation, while the fast response, represented by rise time of system output, can be improved by tuning the controller parameter. We exploit techniques from both the nonlinear systems control and the fractional order systems control to derive a novel nonlinear fractional order controller. For theoretical analysis of the closed-loop system performance, two comparison theorems are developed for a class of fractional differential equations. Moreover, the rise time of the closed-loop system can be estimated, which facilitates our controller design to satisfy the fast response performance and maintain the robustness. Finally, numerical examples are given to illustrate the effectiveness of our methods. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Asymmetric structure of five and six membered DNA hairpin loops
NASA Technical Reports Server (NTRS)
Baumann, U.; Chang, S.
1995-01-01
The tertiary structure of nucleic acid hairpins was elucidated by means of the accessibility of the single-strand-specific nuclease from mung bean. This molecular probe has proven especially useful in determining details of the structural arrangement of the nucleotides within a loop. In this study 3'-labeling is introduced to complement previously used 5'-labeling in order to assess and to exclude possible artifacts of the method. Both labeling procedures result in mutually consistent cleavage patterns. Therefore, methodological artifacts can be excluded and the potential of the nuclease as structural probe is increased. DNA hairpins with five and six membered loops reveal an asymmetric loop structure with a sharp bend of the phosphate-ribose backbone between the second and third nucleotide on the 3'-side of a loop. These hairpin structures differ from smaller loops with 3 or 4 members, which reveal this type of bend between the first and second 3' nucleotide, and resemble with respect to the asymmetry anticodon loops of tRNA.
Fiber-bragg grating-loop ringdown method and apparatus
Wang, Chuji [Starkville, MS
2008-01-29
A device comprising a fiber grating loop ringdown (FGLRD) system of analysis is disclosed. A fiber Bragg grating (FBG) or Long-Period grating (LPG) written in a section of single mode fused silica fiber is incorporated into a fiber loop. By utilizing the wing areas of the gratings' bandwidth as a wavelength dependent attenuator of the light transmission, a fiber grating loop ringdown concept is formed. One aspect of the present invention is temperature sensing, which has been demonstrated using the disclosed device. Temperature measurements in the areas of accuracy, stability, high temperature, and dynamic range are also described.
PID Tuning Using Extremum Seeking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Killingsworth, N; Krstic, M
2005-11-15
Although proportional-integral-derivative (PID) controllers are widely used in the process industry, their effectiveness is often limited due to poor tuning. Manual tuning of PID controllers, which requires optimization of three parameters, is a time-consuming task. To remedy this difficulty, much effort has been invested in developing systematic tuning methods. Many of these methods rely on knowledge of the plant model or require special experiments to identify a suitable plant model. Reviews of these methods are given in [1] and the survey paper [2]. However, in many situations a plant model is not known, and it is not desirable to openmore » the process loop for system identification. Thus a method for tuning PID parameters within a closed-loop setting is advantageous. In relay feedback tuning [3]-[5], the feedback controller is temporarily replaced by a relay. Relay feedback causes most systems to oscillate, thus determining one point on the Nyquist diagram. Based on the location of this point, PID parameters can be chosen to give the closed-loop system a desired phase and gain margin. An alternative tuning method, which does not require either a modification of the system or a system model, is unfalsified control [6], [7]. This method uses input-output data to determine whether a set of PID parameters meets performance specifications. An adaptive algorithm is used to update the PID controller based on whether or not the controller falsifies a given criterion. The method requires a finite set of candidate PID controllers that must be initially specified [6]. Unfalsified control for an infinite set of PID controllers has been developed in [7]; this approach requires a carefully chosen input signal [8]. Yet another model-free PID tuning method that does not require opening of the loop is iterative feedback tuning (IFT). IFT iteratively optimizes the controller parameters with respect to a cost function derived from the output signal of the closed-loop system, see [9]. This method is based on the performance of the closed-loop system during a step response experiment [10], [11]. In this article we present a method for optimizing the step response of a closed-loop system consisting of a PID controller and an unknown plant with a discrete version of extremum seeking (ES). Specifically, ES is used to minimize a cost function similar to that used in [10], [11], which quantifies the performance of the PID controller. ES, a non-model-based method, iteratively modifies the arguments (in this application the PID parameters) of a cost function so that the output of the cost function reaches a local minimum or local maximum. In the next section we apply ES to PID controller tuning. We illustrate this technique through simulations comparing the effectiveness of ES to other PID tuning methods. Next, we address the importance of the choice of cost function and consider the effect of controller saturation. Furthermore, we discuss the choice of ES tuning parameters. Finally, we offer some conclusions.« less
Kellmeyer, Philipp; Cochrane, Thomas; Müller, Oliver; Mitchell, Christine; Ball, Tonio; Fins, Joseph J; Biller-Andorno, Nikola
2016-10-01
Closed-loop medical devices such as brain-computer interfaces are an emerging and rapidly advancing neurotechnology. The target patients for brain-computer interfaces (BCIs) are often severely paralyzed, and thus particularly vulnerable in terms of personal autonomy, decisionmaking capacity, and agency. Here we analyze the effects of closed-loop medical devices on the autonomy and accountability of both persons (as patients or research participants) and neurotechnological closed-loop medical systems. We show that although BCIs can strengthen patient autonomy by preserving or restoring communicative abilities and/or motor control, closed-loop devices may also create challenges for moral and legal accountability. We advocate the development of a comprehensive ethical and legal framework to address the challenges of emerging closed-loop neurotechnologies like BCIs and stress the centrality of informed consent and refusal as a means to foster accountability. We propose the creation of an international neuroethics task force with members from medical neuroscience, neuroengineering, computer science, medical law, and medical ethics, as well as representatives of patient advocacy groups and the public.
The effect of compressive viscosity and thermal conduction on the longitudinal MHD waves
NASA Astrophysics Data System (ADS)
Bahari, K.; Shahhosaini, N.
2018-05-01
longitudinal Magnetohydrodynamic (MHD) oscillations have been studied in a slowly cooling coronal loop, in the presence of thermal conduction and compressive viscosity, in the linear MHD approximation. WKB method has been used to solve the governing equations. In the leading order approximation the dispersion relation has been obtained, and using the first order approximation the time dependent amplitude has been determined. Cooling causes the oscillations to amplify and damping mechanisms are more efficient in hot loops. In cool loops the oscillation amplitude increases with time but in hot loops the oscillation amplitude decreases with time. Our conclusion is that in hot loops the efficiency of the compressive viscosity in damping longitudinal waves is comparable to that of the thermal conduction.
The effect of compressive viscosity and thermal conduction on the longitudinal MHD waves
NASA Astrophysics Data System (ADS)
Bahari, K.; Shahhosaini, N.
2018-07-01
Longitudinal magnetohydrodynamic (MHD) oscillations have been studied in a slowly cooling coronal loop, in the presence of thermal conduction and compressive viscosity, in the linear MHD approximation. The WKB method has been used to solve the governing equations. In the leading order approximation the dispersion relation has been obtained, and using the first-order approximation the time-dependent amplitude has been determined. Cooling causes the oscillations to amplify and damping mechanisms are more efficient in hot loops. In cool loops the oscillation amplitude increases with time but in hot loops the oscillation amplitude decreases with time. Our conclusion is that in hot loops the efficiency of the compressive viscosity in damping longitudinal waves is comparable to that of the thermal conduction.
Advanced MOKE magnetometry in wide-field Kerr-microscopy
NASA Astrophysics Data System (ADS)
Soldatov, I. V.; Schäfer, R.
2017-10-01
The measurement of MOKE (Magneto-Optical Kerr Effect) magnetization loops in a wide-field Kerr microscope offers the advantage that the relevant domain images along the loop can be readily recorded. As the microscope's objective lens is exposed to the magnetic field, the loops are usually strongly distorted by non-linear Faraday rotations of the polarized light that occur in the objective lens and that are superimposed to the MOKE signal. In this paper, an experimental method, based on a motorized analyzer, is introduced which allows to compensate the Faraday contributions, thus leading to pure MOKE loops. A wide field Kerr microscope, equipped with this technology, works well as a laser-based MOKE magnetometer, additionally offering domain images and thus providing the basis for loop interpretation.
Emergency cooling analysis for the loss of coolant malfunction
NASA Technical Reports Server (NTRS)
Peoples, J. A.
1972-01-01
This report examines the dynamic response of a conceptual space power fast-spectrum lithium cooled reactor to the loss of coolant malfunction and several emergency cooling concepts. The results show that, following the loss of primary coolant, the peak temperatures of the center most 73 fuel elements can range from 2556 K to the region of the fuel melting point of 3122 K within 3600 seconds after the start of the accident. Two types of emergency aftercooling concepts were examined: (1) full core open loop cooling and (2) partial core closed loop cooling. The full core open loop concept is a one pass method of supplying lithium to the 247 fuel pins. This method can maintain fuel temperature below the 1611 K transient damage limit but requires a sizable 22,680-kilogram auxiliary lithium supply. The second concept utilizes a redundant internal closed loop to supply lithium to only the central area of each hexagonal fuel array. By using this method and supplying lithium to only the triflute region, fuel temperatures can be held well below the transient damage limit.
Three-Dimensional Echocardiography-Derived Non-Invasive Right Ventricular Pressure-Volume Analysis.
Huang, Kuan-Chih; Lin, Lian-Yu; Hwang, Juey-Jen; Lin, Lung-Chun
2017-09-01
In patients with pulmonary hypertension, repeated evaluations of right ventricular (RV) function are still required for clinical decision making, but the invasive nature of current pressure-volume analysis makes conducting regular follow-ups in a clinical setting infeasible. We enrolled 12 patients with pulmonary arterial hypertension (PAH) and 10 with pulmonary venous hypertension (PVH) May 2016-October 2016. All patients underwent a clinically indicated right heart catheterization (RHC), from which the yielded right ventricular pressure recordings were conjugated with RV volume by 3-D echocardiography to generate a pressure-volume loop. A continuous-wave Doppler envelope of tricuspid regurgitation was transformed into a pressure gradient recording by the simplified Bernoulli equation, and then a systolic pressure gradient-volume (PG-V) diagram was generated from similar methods. The area enclosed by the pressure-volume loop was calculated to represent semi-invasive right ventricular stroke work (RVSW RHC ). The area between the PG-V diagram and x-axis was calculated to estimate non-invasive RVSW (RVSW echo ). Patients with PAH have higher RV pressure, lower pulmonary arterial wedge pressure and larger RV volume that was contributed by the dilation of RV mid-cavity minor dimension. We found no significant difference of traditional parameters between these two groups, but RVSW values were significantly higher in PAH patients. The RVSW values of these two methods were significantly correlated by the equation RVSW echo = 0.8447 RVSW RHC + 129.38 (R 2 = 0.9151, p < 0.001). The linearity remained satisfactory in both groups. We conclude that a PG-V diagram is a reliable method to estimate RVSW and to depict pathophysiological status. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Force-Free Magnetic Fields Calculated from Automated Tracing of Coronal Loops with AIA/SDO
NASA Astrophysics Data System (ADS)
Aschwanden, M. J.
2013-12-01
One of the most realistic magnetic field models of the solar corona is a nonlinear force-free field (NLFFF) solution. There exist about a dozen numeric codes that compute NLFFF solutions based on extrapolations of photospheric vector magnetograph data. However, since the photosphere and lower chromosphere is not force-free, a suitable correction has to be applied to the lower boundary condition. Despite of such "pre-processing" corrections, the resulting theoretical magnetic field lines deviate substantially from observed coronal loop geometries. - Here we developed an alternative method that fits an analytical NLFFF approximation to the observed geometry of coronal loops. The 2D coordinates of the geometry of coronal loop structures observed with AIA/SDO are traced with the "Oriented Coronal CUrved Loop Tracing" (OCCULT-2) code, an automated pattern recognition algorithm that has demonstrated the fidelity in loop tracing matching visual perception. A potential magnetic field solution is then derived from a line-of-sight magnetogram observed with HMI/SDO, and an analytical NLFFF approximation is then forward-fitted to the twisted geometry of coronal loops. We demonstrate the performance of this magnetic field modeling method for a number of solar active regions, before and after major flares observed with SDO. The difference of the NLFFF and the potential field energies allows us then to compute the free magnetic energy, which is an upper limit of the energy that is released during a solar flare.
NASA Astrophysics Data System (ADS)
Pascoe, D. J.; Anfinogentov, S. A.; Goddard, C. R.; Nakariakov, V. M.
2018-06-01
The shape of the damping profile of kink oscillations in coronal loops has recently allowed the transverse density profile of the loop to be estimated. This requires accurate measurement of the damping profile that can distinguish the Gaussian and exponential damping regimes, otherwise there are more unknowns than observables. Forward modeling of the transverse intensity profile may also be used to estimate the width of the inhomogeneous layer of a loop, providing an independent estimate of one of these unknowns. We analyze an oscillating loop for which the seismological determination of the transverse structure is inconclusive except when supplemented by additional spatial information from the transverse intensity profile. Our temporal analysis describes the motion of a coronal loop as a kink oscillation damped by resonant absorption, and our spatial analysis is based on forward modeling the transverse EUV intensity profile of the loop under the isothermal and optically thin approximations. We use Bayesian analysis and Markov chain Monte Carlo sampling to apply our spatial and temporal models both individually and simultaneously to our data and compare the results with numerical simulations. Combining the two methods allows both the inhomogeneous layer width and density contrast to be calculated, which is not possible for the same data when each method is applied individually. We demonstrate that the assumption of an exponential damping profile leads to a significantly larger error in the inferred density contrast ratio compared with a Gaussian damping profile.
Ruan, Hang; Li, Jian; Zhang, Lei; Long, Teng
2015-01-01
For vehicle positioning with Global Navigation Satellite System (GNSS) in urban areas, open-loop tracking shows better performance because of its high sensitivity and superior robustness against multipath. However, no previous study has focused on the effects of the code search grid size on the code phase measurement accuracy of open-loop tracking. Traditional open-loop tracking methods are performed by the batch correlators with fixed correlation space. The code search grid size, which is the correlation space, is a constant empirical value and the code phase measuring accuracy will be largely degraded due to the improper grid size, especially when the signal carrier-to-noise density ratio (C/N0) varies. In this study, the Adaptive Correlation Space Adjusted Open-Loop Tracking Approach (ACSA-OLTA) is proposed to improve the code phase measurement dependent pseudo range accuracy. In ACSA-OLTA, the correlation space is adjusted according to the signal C/N0. The novel Equivalent Weighted Pseudo Range Error (EWPRE) is raised to obtain the optimal code search grid sizes for different C/N0. The code phase measuring errors of different measurement calculation methods are analyzed for the first time. The measurement calculation strategy of ACSA-OLTA is derived from the analysis to further improve the accuracy but reduce the correlator consumption. Performance simulation and real tests confirm that the pseudo range and positioning accuracy of ASCA-OLTA are better than the traditional open-loop tracking methods in the usual scenarios of urban area. PMID:26343683
Polyakov loop fluctuations in the presence of external fields
NASA Astrophysics Data System (ADS)
Lo, Pok Man; Szymański, Michał; Redlich, Krzysztof; Sasaki, Chihiro
2018-06-01
We study the implications of the spontaneous and explicit Z(3) center symmetry breaking for the Polyakov loop susceptibilities. To this end, ratios of the susceptibilities of the real and imaginary parts, as well as of the modulus of the Polyakov loop are computed within an effective model using a color group integration scheme. We show that the essential features of the lattice QCD results of these ratios can be successfully captured by the effective approach. Furthermore we discuss a novel scaling relation in one of these ratios involving the explicit breaking field, volume, and temperature.
Dynamic simulation of perturbation responses in a closed-loop virtual arm model.
Du, Yu-Fan; He, Xin; Lan, Ning
2010-01-01
A closed-loop virtual arm (VA) model has been developed in SIMULINK environment by adding spinal reflex circuits and propriospinal neural networks to the open-loop VA model developed in early study [1]. An improved virtual muscle model (VM4.0) is used to speed up simulation and to generate more precise recruitment of muscle force at low levels of muscle activation. Time delays in the reflex loops are determined by their synaptic connections and afferent transmission back to the spinal cord. Reflex gains are properly selected so that closed-loop responses are stable. With the closed-loop VA model, we are developing an approach to evaluate system behaviors by dynamic simulation of perturbation responses. Joint stiffness is calculated based on simulated perturbation responses by a least-squares algorithm in MATLAB. This method of dynamic simulation will be essential for further evaluation of feedforward and reflex control of arm movement and position.
Damped transverse oscillations of interacting coronal loops
NASA Astrophysics Data System (ADS)
Soler, Roberto; Luna, Manuel
2015-10-01
Damped transverse oscillations of magnetic loops are routinely observed in the solar corona. This phenomenon is interpreted as standing kink magnetohydrodynamic waves, which are damped by resonant absorption owing to plasma inhomogeneity across the magnetic field. The periods and damping times of these oscillations can be used to probe the physical conditions of the coronal medium. Some observations suggest that interaction between neighboring oscillating loops in an active region may be important and can modify the properties of the oscillations. Here we theoretically investigate resonantly damped transverse oscillations of interacting nonuniform coronal loops. We provide a semi-analytic method, based on the T-matrix theory of scattering, to compute the frequencies and damping rates of collective oscillations of an arbitrary configuration of parallel cylindrical loops. The effect of resonant damping is included in the T-matrix scheme in the thin boundary approximation. Analytic and numerical results in the specific case of two interacting loops are given as an application.
Current systems of coronal loops in 3D MHD simulations
NASA Astrophysics Data System (ADS)
Warnecke, J.; Chen, F.; Bingert, S.; Peter, H.
2017-11-01
Aims: We study the magnetic field and current structure associated with a coronal loop. Through this we investigate to what extent the assumptions of a force-free magnetic field break down and where they might be justified. Methods: We analyze a three-dimensional (3D) magnetohydrodynamic (MHD) model of the solar corona in an emerging active region with the focus on the structure of the forming coronal loops. The lower boundary of this simulation is taken from a model of an emerging active region. As a consequence of the emerging magnetic flux and the horizontal motions at the surface a coronal loop forms self-consistently. We investigate the current density along magnetic field lines inside (and outside) this loop and study the magnetic and plasma properties in and around this loop. The loop is defined as the bundle of field lines that coincides with enhanced emission in extreme UV. Results: We find that the total current along the emerging loop changes its sign from being antiparallel to parallel to the magnetic field. This is caused by the inclination of the loop together with the footpoint motion. Around the loop, the currents form a complex non-force-free helical structure. This is directly related to a bipolar current structure at the loop footpoints at the base of the corona and a local reduction of the background magnetic field (I.e., outside the loop) caused by the plasma flow into and along the loop. Furthermore, the locally reduced magnetic pressure in the loop allows the loop to sustain a higher density, which is crucial for the emission in extreme UV. The action of the flow on the magnetic field hosting the loop turns out to also be responsible for the observed squashing of the loop. Conclusions: The complex magnetic field and current system surrounding it can only be modeled in 3D MHD models where the magnetic field has to balance the plasma pressure. A one-dimensional coronal loop model or a force-free extrapolation cannot capture the current system and the complex interaction of the plasma and the magnetic field in the coronal loop, despite the fact that the loop is under low-β conditions.
Conformational motions regulate phosphoryl transfer in related protein tyrosine phosphatases
Whittier, Sean K.; Hengge, Alvan C.; Loria, J. Patrick
2014-01-01
Many studies have implicated a role for conformational motions during the catalytic cycle, acting to optimize the binding pocket or facilitate product release, but a more intimate role in the chemical reaction has not been described. We address this by monitoring active-site loop motion in two protein tyrosine phosphatases (PTPs) using NMR spectroscopy. The PTPs, YopH and PTP1B, have very different catalytic rates, however we find in both that the active-site loop closes to its catalytically competent position at rates that mirror the phosphotyrosine cleavage kinetics. This loop contains the catalytic acid, suggesting that loop closure occurs concomitantly with the protonation of the leaving group tyrosine and explains the different kinetics of two otherwise chemically and mechanistically indistinguishable enzymes. PMID:23970698
Ojha, Saroj Kumar; Javdekar, Sadashiv Bhaskar; Dhir, Sangeeta
2015-01-01
Context: Plaque control has been shown to be pivotal in maintaining the optimal periodontal health. Mechanical plaque control is the most popular option for establishing the optimal oral health. Toothbrushes have been the novel tool for mechanical cleansing. However, the abrasive potential of the toothbrushes on the enamel surface is an area in gray. Aims: The aim of this in vitro study is to evaluate the abrasivity of the toothbrush versus the velcro fasteners. Materials and Methods: The mounted teeth of both the groups were subjected to abrasion test, and the tooth surfaces were observed for the possible abrasions from the oscillating strokes (toothbrush) and frictional contacts (hook and loop velcro) and examined under the scanning electron microscope. Results: Comparative assessment of both velcro (hook and loop) and toothbrush bristles did not reveal any evidence of abrasion on the tooth specimens. Conclusions: Veclro fasteners are safe and qualitatively at par to the manual toothbrush for their efficacy and efficiency in teeth cleansing PMID:26229264
NASA Technical Reports Server (NTRS)
Mukkamala, R.; Mathias, J. M.; Mullen, T. J.; Cohen, R. J.; Freeman, R.
1999-01-01
We applied cardiovascular system identification (CSI) to characterize closed-loop cardiovascular regulation in patients with diabetic autonomic neuropathy (DAN). The CSI method quantitatively analyzes beat-to-beat fluctuations in noninvasively measured heart rate, arterial blood pressure (ABP), and instantaneous lung volume (ILV) to characterize four physiological coupling mechanisms, two of which are autonomically mediated (the heart rate baroreflex and the coupling of respiration, measured in terms of ILV, to heart rate) and two of which are mechanically mediated (the coupling of ventricular contraction to the generation of the ABP wavelet and the coupling of respiration to ABP). We studied 37 control and 60 diabetic subjects who were classified as having minimal, moderate, or severe DAN on the basis of standard autonomic tests. The autonomically mediated couplings progressively decreased with increasing severity of DAN, whereas the mechanically mediated couplings were essentially unchanged. CSI identified differences between the minimal DAN and control groups, which were indistinguishable based on the standard autonomic tests. CSI may provide a powerful tool for assessing DAN.
Gifford, Lida K.; Opalinska, Joanna B.; Jordan, David; Pattanayak, Vikram; Greenham, Paul; Kalota, Anna; Robbins, Michelle; Vernovsky, Kathy; Rodriguez, Lesbeth C.; Do, Bao T.; Lu, Ponzy; Gewirtz, Alan M.
2005-01-01
We describe a physical mRNA mapping strategy employing fluorescent self-quenching reporter molecules (SQRMs) that facilitates the identification of mRNA sequence accessible for hybridization with antisense nucleic acids in vitro and in vivo, real time. SQRMs are 20–30 base oligodeoxynucleotides with 5–6 bp complementary ends to which a 5′ fluorophore and 3′ quenching group are attached. Alone, the SQRM complementary ends form a stem that holds the fluorophore and quencher in contact. When the SQRM forms base pairs with its target, the structure separates the fluorophore from the quencher. This event can be reported by fluorescence emission when the fluorophore is excited. The stem–loop of the SQRM suggests that SQRM be made to target natural stem–loop structures formed during mRNA synthesis. The general utility of this method is demonstrated by SQRM identification of targetable sequence within c-myb and bcl-6 mRNA. Corresponding antisense oligonucleotides reduce these gene products in cells. PMID:15718294
Lam, Jacob; Wilkinson, James; Brassett, Cecilia; Brown, Jonathan
2018-05-01
Background and study aim Magnetic imaging technology is of proven benefit to trainees in colonoscopy, but few studies have examined its benefits in experienced hands. There is evidence that colonoscopy is more difficult in women. We set out to investigate (i) associations between the looping configurations in the proximal and distal colon and (ii) differences in the looping prevalence between the sexes. We have examined their significance in terms of segmental intubation times and position changes required for the completion of colonoscopy. Patients and methods We analyzed 103 consecutive synchronized luminal and magnetic image videos of diagnostic colonoscopies with normal anatomy undertaken by a single experienced operator. Results Deep transverse loops and sigmoid N-loops were more common in females. A deep transverse loop was more likely to be present if a sigmoid alpha-loop or N-loop had formed previously. Patients with sigmoid N-loops were turned more frequently from left lateral to supine before the sigmoid-descending junction was reached, but there was no statistical correlation between completion time and looping pattern. Conclusions This study has reexamined the prevalence of the common looping patterns encountered during colonoscopy and has identified differences between the sexes. This finding may offer an explanation as to why colonoscopy has been shown to be more difficult in females. Although a deep transverse loop following a resolved sigmoid alpha-loop was the most commonly encountered pattern, no statistical correlation between completion time and looping pattern could be shown. It is the first study to examine segmental completion times using a magnetic imager in expert hands.
NASA Astrophysics Data System (ADS)
Kazantsev, A. E.; Shakhmanov, V. Yu.; Stepanyantz, K. V.
2018-04-01
We investigate a recently proposed new form of the exact NSVZ β-function, which relates the β-function to the anomalous dimensions of the quantum gauge superfield, of the Faddeev-Popov ghosts, and of the chiral matter superfields. Namely, for the general renormalizable N = 1 supersymmetric gauge theory, regularized by higher covariant derivatives, the sum of all three-loop contributions to the β-function containing the Yukawa couplings is compared with the corresponding two-loop contributions to the anomalous dimensions of the quantum superfields. It is demonstrated that for the considered terms both new and original forms of the NSVZ relation are valid independently of the subtraction scheme if the renormalization group functions are defined in terms of the bare couplings. This result is obtained from the equality relating the loop integrals, which, in turn, follows from the factorization of the integrals for the β-function into integrals of double total derivatives. For the renormalization group functions defined in terms of the renormalized couplings we verify that the NSVZ scheme is obtained with the higher covariant derivative regularization supplemented by the subtraction scheme in which only powers of ln Λ /μ are included into the renormalization constants.
Method for determining how to operate and control wind turbine arrays in utility systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Javid, S.H.; Hauth, R.L.; Younkins, T.D.
1984-01-01
A method for determining how utility wind turbine arrays should be controlled and operated on the load frequency control time-scale is presented. Initial considerations for setting wind turbine control requirements are followed by a description of open loop operation and of closed loop and feed forward wind turbine array control concepts. The impact of variations in array output on meeting minimum criteria are developed. The method for determining the required control functions is then presented and results are tabulated. (LEW)
Depression as a systemic syndrome: mapping the feedback loops of major depressive disorder
Wittenborn, A. K.; Rahmandad, H.; Rick, J.; Hosseinichimeh, N.
2016-01-01
Background Depression is a complex public health problem with considerable variation in treatment response. The systemic complexity of depression, or the feedback processes among diverse drivers of the disorder, contribute to the persistence of depression. This paper extends prior attempts to understand the complex causal feedback mechanisms that underlie depression by presenting the first broad boundary causal loop diagram of depression dynamics. Method We applied qualitative system dynamics methods to map the broad feedback mechanisms of depression. We used a structured approach to identify candidate causal mechanisms of depression in the literature. We assessed the strength of empirical support for each mechanism and prioritized those with support from validation studies. Through an iterative process, we synthesized the empirical literature and created a conceptual model of major depressive disorder. Results The literature review and synthesis resulted in the development of the first causal loop diagram of reinforcing feedback processes of depression. It proposes candidate drivers of illness, or inertial factors, and their temporal functioning, as well as the interactions among drivers of depression. The final causal loop diagram defines 13 key reinforcing feedback loops that involve nine candidate drivers of depression. Conclusions Future research is needed to expand upon this initial model of depression dynamics. Quantitative extensions may result in a better understanding of the systemic syndrome of depression and contribute to personalized methods of evaluation, prevention and intervention. PMID:26621339
Learning from ISS-modular adaptive NN control of nonlinear strict-feedback systems.
Wang, Cong; Wang, Min; Liu, Tengfei; Hill, David J
2012-10-01
This paper studies learning from adaptive neural control (ANC) for a class of nonlinear strict-feedback systems with unknown affine terms. To achieve the purpose of learning, a simple input-to-state stability (ISS) modular ANC method is first presented to ensure the boundedness of all the signals in the closed-loop system and the convergence of tracking errors in finite time. Subsequently, it is proven that learning with the proposed stable ISS-modular ANC can be achieved. The cascade structure and unknown affine terms of the considered systems make it very difficult to achieve learning using existing methods. To overcome these difficulties, the stable closed-loop system in the control process is decomposed into a series of linear time-varying (LTV) perturbed subsystems with the appropriate state transformation. Using a recursive design, the partial persistent excitation condition for the radial basis function neural network (NN) is established, which guarantees exponential stability of LTV perturbed subsystems. Consequently, accurate approximation of the closed-loop system dynamics is achieved in a local region along recurrent orbits of closed-loop signals, and learning is implemented during a closed-loop feedback control process. The learned knowledge is reused to achieve stability and an improved performance, thereby avoiding the tremendous repeated training process of NNs. Simulation studies are given to demonstrate the effectiveness of the proposed method.
Conformal blocks from Wilson lines with loop corrections
NASA Astrophysics Data System (ADS)
Hikida, Yasuaki; Uetoko, Takahiro
2018-04-01
We compute the conformal blocks of the Virasoro minimal model or its WN extension with large central charge from Wilson line networks in a Chern-Simons theory including loop corrections. In our previous work, we offered a prescription to regularize divergences from loops attached to Wilson lines. In this paper, we generalize our method with the prescription by dealing with more general operators for N =3 and apply it to the identity W3 block. We further compute general light-light blocks and heavy-light correlators for N =2 with the Wilson line method and compare the results with known ones obtained using a different prescription. We briefly discuss general W3 blocks.
Canonical methods in classical and quantum gravity: An invitation to canonical LQG
NASA Astrophysics Data System (ADS)
Reyes, Juan D.
2018-04-01
Loop Quantum Gravity (LQG) is a candidate quantum theory of gravity still under construction. LQG was originally conceived as a background independent canonical quantization of Einstein’s general relativity theory. This contribution provides some physical motivations and an overview of some mathematical tools employed in canonical Loop Quantum Gravity. First, Hamiltonian classical methods are reviewed from a geometric perspective. Canonical Dirac quantization of general gauge systems is sketched next. The Hamiltonian formultation of gravity in geometric ADM and connection-triad variables is then presented to finally lay down the canonical loop quantization program. The presentation is geared toward advanced undergradute or graduate students in physics and/or non-specialists curious about LQG.
Batteryless implanted echosonometer
NASA Technical Reports Server (NTRS)
Kojima, G. K.
1977-01-01
Miniature ultrasonic echosonometer implanted within laboratory animals obtains energy from RF power oscillator that is electronically transduced via induction loop to power receiving loop located just under animal's skin. Method of powering device offers significant advantages over those in which battery is part of implanted package.
Evidence for maximal acceleration and singularity resolution in covariant loop quantum gravity.
Rovelli, Carlo; Vidotto, Francesca
2013-08-30
A simple argument indicates that covariant loop gravity (spin foam theory) predicts a maximal acceleration and hence forbids the development of curvature singularities. This supports the results obtained for cosmology and black holes using canonical methods.
The architecture of metal coordination groups in proteins.
Harding, Marjorie M
2004-05-01
A set of tables is presented and a survey given of the architecture of metal coordination groups in a representative set of protein structures from the Protein Data Bank [Bernstein et al. (1977), J. Mol. Biol. 112, 535-542; Berman et al. (2000), Nucleic Acids Res. 28, 235-242]. The structures have been determined to a resolution of 2.5 A or better; the metals considered are Ca, Mg, Mn, Fe, Cu, Zn, Na and K, with particular emphasis on Ca and Zn and the exclusion of haem groups and Fe/S clusters; the proteins are a representative set in which none has more than 30% sequence identity with any other. In them the metal is coordinated by several donor groups from different amino-acid residues in the protein chain and often also by water or other small molecules. The tables, for approximately 600 metal coordination groups, include information on the conformations of the protein chain in the region around the metal and reliability indicators. They illustrate the wide variety of coordination numbers, chelate-loop sizes and other properties and the different characteristics of different metals. They show that glycine has a particular significance in the position adjacent to a donor residue, especially in Ca coordination groups. They also show that metal coordination does not appear to lead to significant distortions of the torsion angles phi, psi from their normally allowed values. Very few metal coordination groups occur more than once in the representative set and when they do they are usually related in fold and function; they have similar but not necessarily identical conformations. However, individual chelate loops, for example Zn(-C-X-X'-C-), in which both cysteines are coordinated to Zn through S, and X and X' are any amino acids, are repeated frequently in many different and unrelated proteins. Not all chelate loops with the same composition have the same conformation, but for smaller loops there are usually one or two strongly preferred and well defined conformations. Quite frequently more than one metal coordination group is associated with one protein chain; these proteins are identified.
2009-07-28
To compare the effectiveness of punch biopsy and selective recall for treatment versus a policy of immediate treatment by large loop excision in the management of women with low grade abnormal cervical cytology referred for colposcopy. Multicentre individually randomised controlled trial, nested within the NHS cervical screening programmes. Grampian, Tayside, and Nottingham. 1983 women, aged 20-59, with cytology showing borderline nuclear abnormalities or mild dyskaryosis, October 1999-October 2002. Immediate large loop excision or up to four targeted punch biopsies taken immediately with recall for treatment (by large loop excision) if these showed cervical intraepithelial neoplasia grade II or III or worse. Participants were followed for three years, concluding with an exit colposcopy. Clinical end points: cumulative incidence of cervical intraepithelial neoplasia grade II or worse and grade III or worse at three years. Clinically significant anxiety and depression and self reported after effects assessed six weeks after colposcopy, biopsies, or large loop excision. 879 women (44%) had a normal transformation zone at colposcopy and had no further procedures at that time. Colposcopists were less likely to classify the transformation zone as abnormal when the allocation was large loop excision (603 (60%) in the biopsy and selective recall group; 501 (51%) in the immediate large loop excision group). Of women randomised to biopsy and recall, 157 (16%) required a second clinic visit for treatment. Specimens from almost 60% (n=296) of women who underwent immediate large loop excision showed no cervical intraepithelial neoplasia (31%; n=156) or showed cervical intraepithelial neoplasia grade I (28%; n=140). The percentages of women diagnosed with grade II or worse up to and including the exit examination were 22% (n=216) in the biopsy and recall arm and 23% (n=228) in the immediate large loop excision arm. There was no significant difference between the arms in cumulative incidence of cervical intraepithelial neoplasia grade II or worse (adjusted relative for risk large loop excision v biopsy 1.04, 95% confidence interval 0.86 to 1.25) or grade III or worse (1.03, 0.79 to 1.34). A greater proportion of disease was detected at initial investigation and less during follow-up and at exit in the immediate large loop excision arm, but time of detection did not differ significantly between arms. Levels of anxiety and depression and reported pain did not differ between arms. Higher proportions of women randomised to large loop excision reported moderate or more severe bleeding and discharge. A policy of targeted punch biopsies with subsequent treatment for cervical intraepithelial neoplasia grade II or III and cytological surveillance for grade I or less provides the best balance between benefits and harms for the management of women with low grade abnormal cytology referred for colposcopy. Immediate large loop excision results in overtreatment and more after effects and should not be recommended. ISRCTN 34841617.
On the asymptotic states and the quantum S matrix of the η-deformed AdS 5 × S 5 superstring
Engelund, Oluf Tang; Roiban, Radu
2015-03-31
We investigate the worldsheet S matrix of string theory in η-deformed AdS 5 × S 5. By computing the six-point tree-level S matrix we explicitly show that there is no particle production at this level, as required by the classical integrability of the theory. At one and two loops we show that integrability requires that the classical two-particle states be redefined in a non-local and η-dependent way. This is a significant departure from the undeformed theory which is probably related to the quantum group symmetry of the worldsheet theory. We use generalized unitarity to carry out the loop calculations andmore » identify a set of integrals that allow us to give a two-loop Feynman integral representation of the logarithmic terms of the two-loop S matrix. We finally also discuss aspects of the calculation of the two-loop rational terms.« less
Comparison between electric dipole and magnetic loop antennas for emitting whistler modes
NASA Astrophysics Data System (ADS)
Stenzel, R.; Urrutia, J. M.
2016-12-01
In a large uniform and unbounded laboratory plasma low frequency whistler modes are excited from an electric dipole and a magnetic loop. The excited waves are measured with a magnetic probe which resolves the three field components in 3D space and time. This yields the group velocity and energy density, from which one obtains the emitted power. The same rf generator is used for both antennas and the radiated power is measured under identical plasma conditions. The magnetic loop radiates 8000 times more power than the electric dipole. The reason is that the loop antenna carries a large conduction current while the electric dipole current is a much smaller displacement current through the sheath. The current, hence magnetic field excites whistlers, not the dipole electric field. Incidentally, a dipole antenna does not launch plane waves but m = 1 helicon modes. The findings suggest that active wave injections into the magnetosphere should be done with magnetic antennas. Two parallel dipoles connected at the free end could serve as an elongated loop.
Resection with laser and high frequency cutting loop in tracheo-bronchial diseases.
Illum, P
1989-04-01
A total of 23 patients have been treated endoscopically during the last three and a half years for a variety of diseases in the tracheo-bronchial tree; nine had a tracheal stenosis. Thirteen patients have been treated by resection with a high frequency cutting loop, eleven with a CO2-laser and one with an argon laser. A total of 44 treatments have been performed. Half of the treatments were given because of various malignant diseases. The results of the treatment of this very mixed group of patients were, as a whole, satisfactory with both CO2-laser and cutting loop. A more precise technique can be applied with the CO2-laser than the cutting loop, though the latter is the more efficient and easy to work with. Care must be taken with the loop because of its greater cutting depth. The argon laser has only limited use in the treatment of diseases in the trachea.
Mohanta, Tapan Kumar; Arora, Pankaj Kumar; Mohanta, Nibedita; Parida, Pratap; Bae, Hanhong
2015-02-06
Mitogen Activated Protein Kinase (MAPK) signaling is of critical importance in plants and other eukaryotic organisms. The MAPK cascade plays an indispensible role in the growth and development of plants, as well as in biotic and abiotic stress responses. The MAPKs are constitute the most downstream module of the three tier MAPK cascade and are phosphorylated by upstream MAP kinase kinases (MAPKK), which are in turn are phosphorylated by MAP kinase kinase kinase (MAPKKK). The MAPKs play pivotal roles in regulation of many cytoplasmic and nuclear substrates, thus regulating several biological processes. A total of 589 MAPKs genes were identified from the genome wide analysis of 40 species. The sequence analysis has revealed the presence of several N- and C-terminal conserved domains. The MAPKs were previously believed to be characterized by the presence of TEY/TDY activation loop motifs. The present study showed that, in addition to presence of activation loop TEY/TDY motifs, MAPKs are also contain MEY, TEM, TQM, TRM, TVY, TSY, TEC and TQY activation loop motifs. Phylogenetic analysis of all predicted MAPKs were clustered into six different groups (group A, B, C, D, E and F), and all predicted MAPKs were assigned with specific names based on their orthology based evolutionary relationships with Arabidopsis or Oryza MAPKs. We conducted global analysis of the MAPK gene family of plants from lower eukaryotes to higher eukaryotes and analyzed their genomic and evolutionary aspects. Our study showed the presence of several new activation loop motifs and diverse conserved domains in MAPKs. Advance study of newly identified activation loop motifs can provide further information regarding the downstream signaling cascade activated in response to a wide array of stress conditions, as well as plant growth and development.
Nailfold capillary patterns in healthy subjects: a real issue in capillaroscopy.
Ingegnoli, Francesca; Gualtierotti, Roberta; Lubatti, Chiara; Bertolazzi, Chiara; Gutierrez, Marwin; Boracchi, Patrizia; Fornili, Marco; De Angelis, Rossella
2013-11-01
Nailfold capillaroscopy has been extensively applied in a broad spectrum of pathologic conditions, but very few data have been published in healthy individuals. The aim of this study was to describe the nailfold capillary findings on a large series of healthy subjects using the video-capillaroscopy technique. Nailfold capillaries were studied based on their morphology, dimensions and density. Then, to evaluate jointly the association between different capillary findings in groups of subjects which were homogeneous for their characteristics, cluster analysis was performed. The results (median) of capillary measurements were as follows: loop length 207μm, external diameter 39μm, internal diameter 17μm, apical diameter 17μm, and intercapillary distance 143μm. Based on the cluster analysis three major "normal" morphologic capillaroscopic patterns were depicted: 1) the "normal" pattern mainly with 2 to 5 U-shaped loops/mm and ≤2 tortuous loops/mm; 2) the "perfect normal" pattern with ≥5 U-shaped loops/mm and 3) the "unusual normal" with at least 1 meandering or bushy loop, or at least 1 microhemorrhage, or with >4 crossed loops/mm. Regarding the loop measurements, the majority of subjects had a median of 7capillaries/mm with a median length of 198μm. © 2013 Elsevier Inc. All rights reserved.
Simple way to calculate a UV-finite one-loop quantum energy in the Randall-Sundrum model
NASA Astrophysics Data System (ADS)
Altshuler, Boris L.
2017-04-01
The surprising simplicity of Barvinsky-Nesterov or equivalently Gelfand-Yaglom methods of calculation of quantum determinants permits us to obtain compact expressions for a UV-finite difference of one-loop quantum energies for two arbitrary values of the parameter of the double-trace asymptotic boundary conditions. This result generalizes the Gubser and Mitra calculation for the particular case of difference of "regular" and "irregular" one-loop energies in the one-brane Randall-Sundrum model. The approach developed in the paper also allows us to get "in one line" the one-loop quantum energies in the two-brane Randall-Sundrum model. The relationship between "one-loop" expressions corresponding to the mixed Robin and to double-trace asymptotic boundary conditions is traced.
Mathematical Modeling of Loop Heat Pipes
NASA Technical Reports Server (NTRS)
Kaya, Tarik; Ku, Jentung; Hoang, Triem T.; Cheung, Mark L.
1998-01-01
The primary focus of this study is to model steady-state performance of a Loop Heat Pipe (LHP). The mathematical model is based on the steady-state energy balance equations at each component of the LHP. The heat exchange between each LHP component and the surrounding is taken into account. Both convection and radiation environments are modeled. The loop operating temperature is calculated as a function of the applied power at a given loop condition. Experimental validation of the model is attempted by using two different LHP designs. The mathematical model is tested at different sink temperatures and at different elevations of the loop. Tbc comparison of the calculations and experimental results showed very good agreement (within 3%). This method proved to be a useful tool in studying steady-state LHP performance characteristics.
In-loop flow [11 C]CO2 fixation and radiosynthesis of N,N'-[11 C]dibenzylurea.
Downey, Joseph; Bongarzone, Salvatore; Hader, Stefan; Gee, Antony D
2018-03-01
Cyclotron-produced carbon-11 is a highly valuable radionuclide for the production of positron emission tomography (PET) radiotracers. It is typically produced as relatively unreactive carbon-11 carbon dioxide ([ 11 C]CO 2 ), which is most commonly converted into a more reactive precursor for synthesis of PET radiotracers. The development of [ 11 C]CO 2 fixation methods has more recently enabled the direct radiolabelling of a diverse array of structures directly from [ 11 C]CO 2 , and the advantages afforded by the use of a loop-based system used in 11 C-methylation and 11 C-carboxylation reactions inspired us to apply the [ 11 C]CO 2 fixation "in-loop." In this work, we developed and investigated a new ethylene tetrafluoroethylene (ETFE) loop-based [ 11 C]CO 2 fixation method, enabling the fast and efficient, direct-from-cyclotron, in-loop trapping of [ 11 C]CO 2 using mixed DBU/amine solutions. An optimised protocol was integrated into a proof-of-concept in-loop flow radiosynthesis of N,N'-[ 11 C]dibenzylurea. This reaction exhibited an average 78% trapping efficiency and a crude radiochemical purity of 83% (determined by radio-HPLC), giving an overall nonisolated radiochemical yield of 72% (decay-corrected) within just 3 minutes from end of bombardment. This proof-of-concept reaction has demonstrated that efficient [ 11 C]CO 2 fixation can be achieved in a low-volume (150 μL) ETFE loop and that this can be easily integrated into a rapid in-loop flow radiosynthesis of carbon-11-labelled products. This new in-loop methodology will allow fast radiolabelling reactions to be performed using cheap/disposable ETFE tubing setup (ideal for good manufacturing practice production) thereby contributing to the widespread usage of [ 11 C]CO 2 trapping/fixation reactions for the production of PET radiotracers. © 2017 The Authors. Journal of Labelled Compounds and Radiopharmaceuticals Published by John Wiley & Sons, Ltd.
Dynamics of a multi-thermal loop in the solar corona
NASA Astrophysics Data System (ADS)
Nisticò, G.; Anfinogentov, S.; Nakariakov, V. M.
2014-10-01
Context. We present an observation of a long-living multi-thermal coronal loop, visible in different extreme ultra-violet wavebands of SDO/AIA in a quiet-Sun region close to the western solar limb. Aims: Analysis of persistent kink displacements of the loop seen in different bandpasses that correspond to different temperatures of the plasma allows sub-resolution structuring of the loop to be revealed. Methods: A vertically oriented slit is taken at the loop top, and time-distance maps are made from it. Loop displacements in time-distance maps are automatically tracked with the Gaussian fitting technique and fitted with a sinusoidal function that is "guessed". Wavelet transforms are further used in order to quantify the periodicity variation in time of the kink oscillations. Results: The loop strands are found to oscillate with the periods ranging between 3 and 15 min. The oscillations are observed in intermittent regime with temporal changes in the period and amplitude. The oscillations are different at three analysed wavelengths. Conclusions: This finding suggests that the loop-like threads seen at different wavelengths are not co-spatial, hence that the loop consists of several multi-thermal strands. The detected irregularity of the oscillations can be associated with a stochastic driver acting at the footpoints of the loop. A movie associated to Fig. 1 is available in electronic form at http://www.aanda.org
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Haixia; Li, Bo; Huang, Zhenghua
How the solar corona is heated to high temperatures remains an unsolved mystery in solar physics. In the present study we analyze observations of 50 whole active region loops taken with the Extreme-ultraviolet Imaging Spectrometer on board the Hinode satellite. Eleven loops were classified as cool loops (<1 MK) and 39 as warm loops (1–2 MK). We study their plasma parameters, such as densities, temperatures, filling factors, nonthermal velocities, and Doppler velocities. We combine spectroscopic analysis with linear force-free magnetic field extrapolation to derive the 3D structure and positioning of the loops, their lengths and heights, and the magnetic fieldmore » strength along the loops. We use density-sensitive line pairs from Fe xii, Fe xiii, Si x, and Mg vii ions to obtain electron densities by taking special care of intensity background subtraction. The emission measure loci method is used to obtain the loop temperatures. We find that the loops are nearly isothermal along the line of sight. Their filling factors are between 8% and 89%. We also compare the observed parameters with the theoretical Rosner–Tucker–Vaiana (RTV) scaling law. We find that most of the loops are in an overpressure state relative to the RTV predictions. In a follow-up study, we will report a heating model of a parallel-cascade-based mechanism and will compare the model parameters with the loop plasma and structural parameters derived here.« less
Hartono, Stella R; Malapert, Amélie; Legros, Pénélope; Bernard, Pascal; Chédin, Frédéric; Vanoosthuyse, Vincent
2018-02-02
R-loops, which result from the formation of stable DNA:RNA hybrids, can both threaten genome integrity and act as physiological regulators of gene expression and chromatin patterning. To characterize R-loops in fission yeast, we used the S9.6 antibody-based DRIPc-seq method to sequence the RNA strand of R-loops and obtain strand-specific R-loop maps at near nucleotide resolution. Surprisingly, preliminary DRIPc-seq experiments identified mostly RNase H-resistant but exosome-sensitive RNAs that mapped to both DNA strands and resembled RNA:RNA hybrids (dsRNAs), suggesting that dsRNAs form widely in fission yeast. We confirmed in vitro that S9.6 can immuno-precipitate dsRNAs and provide evidence that dsRNAs can interfere with its binding to R-loops. dsRNA elimination by RNase III treatment prior to DRIPc-seq allowed the genome-wide and strand-specific identification of genuine R-loops that responded in vivo to RNase H levels and displayed classical features associated with R-loop formation. We also found that most transcripts whose levels were altered by in vivo manipulation of RNase H levels did not form detectable R-loops, suggesting that prolonged manipulation of R-loop levels could indirectly alter the transcriptome. We discuss the implications of our work in the design of experimental strategies to probe R-loop functions. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Panahi, Nima S.
We studied the problem of understanding and computing the essential features and dynamics of molecular motions through the development of two theories for two different systems. First, we studied the process of the Berry Pseudorotation of PF5 and the rotations it induces in the molecule through its natural and intrinsic geometric nature by setting it in the language of fiber bundles and graph theory. With these tools, we successfully extracted the essentials of the process' loops and induced rotations. The infinite number of pseudorotation loops were broken down into a small set of essential loops called "super loops", with their intrinsic properties and link to the physical movements of the molecule extensively studied. In addition, only the three "self-edge loops" generated any induced rotations, and then only a finite number of classes of them. Second, we studied applying the statistical methods of Principal Components Analysis (PCA) and Principal Coordinate Analysis (PCO) to capture only the most important changes in Argon clusters so as to reduce computational costs and graph the potential energy surface (PES) in three dimensions respectively. Both methods proved successful, but PCA was only partially successful since one will only see advantages for PES database systems much larger than those both currently being studied and those that can be computationally studied in the next few decades to come. In addition, PCA is only needed for the very rare case of a PES database that does not already include Hessian eigenvalues.
Extended molecular dynamics of a c-kit promoter quadruplex
Islam, Barira; Stadlbauer, Petr; Krepl, Miroslav; Koca, Jaroslav; Neidle, Stephen; Haider, Shozeb; Sponer, Jiri
2015-01-01
The 22-mer c-kit promoter sequence folds into a parallel-stranded quadruplex with a unique structure, which has been elucidated by crystallographic and NMR methods and shows a high degree of structural conservation. We have carried out a series of extended (up to 10 μs long, ∼50 μs in total) molecular dynamics simulations to explore conformational stability and loop dynamics of this quadruplex. Unfolding no-salt simulations are consistent with a multi-pathway model of quadruplex folding and identify the single-nucleotide propeller loops as the most fragile part of the quadruplex. Thus, formation of propeller loops represents a peculiar atomistic aspect of quadruplex folding. Unbiased simulations reveal μs-scale transitions in the loops, which emphasizes the need for extended simulations in studies of quadruplex loops. We identify ion binding in the loops which may contribute to quadruplex stability. The long lateral-propeller loop is internally very stable but extensively fluctuates as a rigid entity. It creates a size-adaptable cleft between the loop and the stem, which can facilitate ligand binding. The stability gain by forming the internal network of GA base pairs and stacks of this loop may be dictating which of the many possible quadruplex topologies is observed in the ground state by this promoter quadruplex. PMID:26245347
New variables for classical and quantum gravity in all dimensions: I. Hamiltonian analysis
NASA Astrophysics Data System (ADS)
Bodendorfer, N.; Thiemann, T.; Thurn, A.
2013-02-01
Loop quantum gravity (LQG) relies heavily on a connection formulation of general relativity such that (1) the connection Poisson commutes with itself and (2) the corresponding gauge group is compact. This can be achieved starting from the Palatini or Holst action when imposing the time gauge. Unfortunately, this method is restricted to D + 1 = 4 spacetime dimensions. However, interesting string theories and supergravity theories require higher dimensions and it would therefore be desirable to have higher dimensional supergravity loop quantizations at one’s disposal in order to compare these approaches. In this series of papers we take first steps toward this goal. The present first paper develops a classical canonical platform for a higher dimensional connection formulation of the purely gravitational sector. The new ingredient is a different extension of the ADM phase space than the one used in LQG which does not require the time gauge and which generalizes to any dimension D > 1. The result is a Yang-Mills theory phase space subject to Gauß, spatial diffeomorphism and Hamiltonian constraint as well as one additional constraint, called the simplicity constraint. The structure group can be chosen to be SO(1, D) or SO(D + 1) and the latter choice is preferred for purposes of quantization.
Closed-loop air cooling system for a turbine engine
North, William Edward
2000-01-01
Method and apparatus are disclosed for providing a closed-loop air cooling system for a turbine engine. The method and apparatus provide for bleeding pressurized air from a gas turbine engine compressor for use in cooling the turbine components. The compressed air is cascaded through the various stages of the turbine. At each stage a portion of the compressed air is returned to the compressor where useful work is recovered.
Pilot-in-the-Loop CFD Method Development
2016-02-01
Contract # N00014-14-C-0020 Pilot-in-the-Loop CFD Method Development Progress Report (CDRL A001) Progress Report for Period: October 21...of the aircraft from the rest of its external environment. For example, ship airwake are calculated using CFD solutions without the presence of the...approaches with the goal of real time, fully coupled CFD for virtual dynamic interface modeling & simulation. Penn State is supporting the project
Pilot-in-the Loop CFD Method Development
2016-04-27
Contract # N00014-14-C-0020 Pilot-in-the-Loop CFD Method Development Progress Report (CDRL A001) Progress Report for Period: January 21...aerodynamics of the aircraft from the rest of its external environment. For example, ship airwake are calculated using CFD solutions without the presence of...hardware approaches with the goal of real time, fully coupled CFD for virtual dynamic interface modeling & simulation. Penn State is supporting the project
Pilot-in-the-Loop CFD Method Development
2017-04-20
the methods on the NAVAIR Manned Flight Simulator. Activities this period During this report period, we implemented the CRAFT CFD code on the...Penn State VLRCROE Flight simulator and performed the first Pilot-in-the-Loop PILCFD tests at Penn State using the COCOA5 clusters. The initial tests...integration of the flight simulator and Penn State computing infrastructure. Initial tests showed slower performance than real-time (3x slower than real
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozisik, H.; Keltie, R.F.
The open loop control technique of predicting a conditioned input signal based on a specified output response for a second order system has been analyzed both analytically and numerically to gain a firm understanding of the method. Differences between this method of control and digital closed loop control using pole cancellation were investigated as a follow up to previous experimental work. Application of the technique to diamond turning using a fast tool is also discussed.
Closed-Loop and Robust Control of Quantum Systems
Wang, Lin-Cheng
2013-01-01
For most practical quantum control systems, it is important and difficult to attain robustness and reliability due to unavoidable uncertainties in the system dynamics or models. Three kinds of typical approaches (e.g., closed-loop learning control, feedback control, and robust control) have been proved to be effective to solve these problems. This work presents a self-contained survey on the closed-loop and robust control of quantum systems, as well as a brief introduction to a selection of basic theories and methods in this research area, to provide interested readers with a general idea for further studies. In the area of closed-loop learning control of quantum systems, we survey and introduce such learning control methods as gradient-based methods, genetic algorithms (GA), and reinforcement learning (RL) methods from a unified point of view of exploring the quantum control landscapes. For the feedback control approach, the paper surveys three control strategies including Lyapunov control, measurement-based control, and coherent-feedback control. Then such topics in the field of quantum robust control as H ∞ control, sliding mode control, quantum risk-sensitive control, and quantum ensemble control are reviewed. The paper concludes with a perspective of future research directions that are likely to attract more attention. PMID:23997680
Assessment of a simple, novel endoluminal method for gastrotomy closure in NOTES.
Lee, Sang Soo; Oelschlager, Brant K; Wright, Andrew S; Soares, Renato V; Sinan, Huseyin; Montenovo, Martin I; Hwang, Joo Ha
2011-10-01
A reliable method for gastrotomy closure in NOTES will be essential for NOTES to become viable clinically. However, methods using existing and widely available endoscopic accessories have been ineffective. The objective of this study was to evaluate the feasibility and safety of a new simple method for gastric closure (retracted clip-assisted loop closure) that uses existing endoscopic accessories with minor modifications. The retracted clip-assisted loop closure technique involves deploying 3-4 Resolution(®) clips (modified by attaching a 90-cm length of suture to the end of each clip) along the margin of the gastrotomy with one jaw on the serosal surface and the other jaw on the mucosal surface. The suture strings are threaded through an endoloop. Traction is then applied to the strings causing the gastric wall to tent. The endoloop is secured below the tip of the clips, completing a full-thickness gastrotomy closure. The main outcome measures were feasibility, efficacy, and safety of the new retracted clip-assisted loop closure technique for NOTES gastrotomy closure. An air-tight seal was achieved in 100% (n = 9) of stomachs. The mean leak pressure was 116.3 (±19.4) mmHg. The retracted clip-assisted loop closure technique can be used to perform NOTES gastrotomy closure by using existing endoscopic accessories with minor modifications.
NASA Astrophysics Data System (ADS)
Kita, Tomoko; Kanaya, Ken
Purpose of this research is to clear present condition of food waste recycling loops based on recycling project certification of the Food Waste Recycling Law. Method of this research is questionnaire survey to companies constituting the loops. Findings of this research are as follows: 1. Proponents of the loop is most often the recycling companies. 2. Food waste recycling rate is 61% for the food retailing industry and 81% for the food service industry. These values are higher than the national average in 2006. The effect of the revision of recycling project certification is suggested.
NASA Astrophysics Data System (ADS)
Ding, Jian; Li, Li
2018-05-01
We initiate the study on chemical distances of percolation clusters for level sets of two-dimensional discrete Gaussian free fields as well as loop clusters generated by two-dimensional random walk loop soups. One of our results states that the chemical distance between two macroscopic annuli away from the boundary for the random walk loop soup at the critical intensity is of dimension 1 with positive probability. Our proof method is based on an interesting combination of a theorem of Makarov, isomorphism theory, and an entropic repulsion estimate for Gaussian free fields in the presence of a hard wall.
NASA Astrophysics Data System (ADS)
Ding, Jian; Li, Li
2018-06-01
We initiate the study on chemical distances of percolation clusters for level sets of two-dimensional discrete Gaussian free fields as well as loop clusters generated by two-dimensional random walk loop soups. One of our results states that the chemical distance between two macroscopic annuli away from the boundary for the random walk loop soup at the critical intensity is of dimension 1 with positive probability. Our proof method is based on an interesting combination of a theorem of Makarov, isomorphism theory, and an entropic repulsion estimate for Gaussian free fields in the presence of a hard wall.
Self-Developed Testing System for Determining the Temperature Behavior of Concrete.
Zhu, He; Li, Qingbin; Hu, Yu
2017-04-16
Cracking due to temperature and restraint in mass concrete is an important issue. A temperature stress testing machine (TSTM) is an effective test method to study the mechanism of temperature cracking. A synchronous closed loop federated control TSTM system has been developed by adopting the design concepts of a closed loop federated control, a detachable mold design, a direct measuring deformation method, and a temperature deformation compensation method. The results show that the self-developed system has the comprehensive ability of simulating different restraint degrees, multiple temperature and humidity modes, and closed-loop control of multi-TSTMs during one test period. Additionally, the direct measuring deformation method can obtain a more accurate deformation and restraint degree result with little local damage. The external temperature deformation affecting the concrete specimen can be eliminated by adopting the temperature deformation compensation method with different considerations of steel materials. The concrete quality of different TSTMs can be guaranteed by being vibrated on the vibrating stand synchronously. The detachable mold design and assembled method has greatly overcome the difficulty of eccentric force and deformation.
Self-Developed Testing System for Determining the Temperature Behavior of Concrete
Zhu, He; Li, Qingbin; Hu, Yu
2017-01-01
Cracking due to temperature and restraint in mass concrete is an important issue. A temperature stress testing machine (TSTM) is an effective test method to study the mechanism of temperature cracking. A synchronous closed loop federated control TSTM system has been developed by adopting the design concepts of a closed loop federated control, a detachable mold design, a direct measuring deformation method, and a temperature deformation compensation method. The results show that the self-developed system has the comprehensive ability of simulating different restraint degrees, multiple temperature and humidity modes, and closed-loop control of multi-TSTMs during one test period. Additionally, the direct measuring deformation method can obtain a more accurate deformation and restraint degree result with little local damage. The external temperature deformation affecting the concrete specimen can be eliminated by adopting the temperature deformation compensation method with different considerations of steel materials. The concrete quality of different TSTMs can be guaranteed by being vibrated on the vibrating stand synchronously. The detachable mold design and assembled method has greatly overcome the difficulty of eccentric force and deformation. PMID:28772778
On-the-fly reduction of open loops
NASA Astrophysics Data System (ADS)
Buccioni, Federico; Pozzorini, Stefano; Zoller, Max
2018-01-01
Building on the open-loop algorithm we introduce a new method for the automated construction of one-loop amplitudes and their reduction to scalar integrals. The key idea is that the factorisation of one-loop integrands in a product of loop segments makes it possible to perform various operations on-the-fly while constructing the integrand. Reducing the integrand on-the-fly, after each segment multiplication, the construction of loop diagrams and their reduction are unified in a single numerical recursion. In this way we entirely avoid objects with high tensor rank, thereby reducing the complexity of the calculations in a drastic way. Thanks to the on-the-fly approach, which is applied also to helicity summation and for the merging of different diagrams, the speed of the original open-loop algorithm can be further augmented in a very significant way. Moreover, addressing spurious singularities of the employed reduction identities by means of simple expansions in rank-two Gram determinants, we achieve a remarkably high level of numerical stability. These features of the new algorithm, which will be made publicly available in a forthcoming release of the OpenLoops program, are particularly attractive for NLO multi-leg and NNLO real-virtual calculations.
Dynamic testing of a single-degree-of-freedom strapdown gyroscope
NASA Technical Reports Server (NTRS)
Lory, C. B.; Feldman, J.; Sinkiewicz, J. S., Jr.
1971-01-01
Test methods and results are presented for the equivalent average input rate of a single-degree-of-freedom gyroscope operated both open loop and with a ternary-logic pulse-torque-to-balance loop during multiaxis angular oscillation. For the open-loop tests, good agreement was obtained with theoretical results. Two-axis testing was performed for oscillations about the Input-Output axes, the Input-Spin axes, and the Spin-Output axes. These tests run in the torque-to-balance mode revealed significant departures from open-loop results in the induced drift rate. An analysis is developed explaining much of the closed-loop data presented. Test data for the gryoscope in a ternary torque-to-balance loop with constant input rates is presented. The tests demonstrate that the instrument rate linearity does not change with interrogation frequency from 3,600 to 14,400 Hz if the torque coil is tuned to offer a resistive load to the current switch. Analysis cited shows that gyroscope lag compensation eliminates multiple pulsing and other equivalent forms of degraded resolution in a wide variety of quantizing loops. This result is test verified for the ternary delta-modulator loop.
Cui, T.J.; Chew, W.C.; Aydiner, A.A.; Wright, D.L.; Smith, D.V.
2001-01-01
In this paper, numerical simulations of a new enhanced very early time electromagnetic (VETEM) prototype system are presented, where a horizontal transmitting loop and two horizontal receiving loops are used to detect buried targets, in which three loops share the same axis and the transmitter is located at the center of receivers. In the new VETEM system, the difference of signals from two receivers is taken to eliminate strong direct-signals from the transmitter and background clutter and furthermore to obtain a better SNR for buried targets. Because strong coupling exists between the transmitter and receivers, accurate analysis of the three-loop antenna system is required, for which a loop-tree basis function method has been utilized to overcome the low-frequency breakdown problem. In the analysis of scattering problem from buried targets, a conjugate gradient (CG) method with fast Fourier transform (FFT) is applied to solve the electric field integral equation. However, the convergence of such CG-FFT algorithm is extremely slow at very low frequencies. In order to increase the convergence rate, a frequency-hopping approach has been used. Finally, the primary, coupling, reflected, and scattered magnetic fields are evaluated at receiving loops to calculate the output electric current. Numerous simulation results are given to interpret the new VETEM system. Comparing with other single-transmitter-receiver systems, the new VETEM has better SNR and ability to reduce the clutter.
A Method for Precision Closed-Loop Irrigation Using a Modified PID Control Algorithm
NASA Astrophysics Data System (ADS)
Goodchild, Martin; Kühn, Karl; Jenkins, Malcolm; Burek, Kazimierz; Dutton, Andrew
2016-04-01
The benefits of closed-loop irrigation control have been demonstrated in grower trials which show the potential for improved crop yields and resource usage. Managing water use by controlling irrigation in response to soil moisture changes to meet crop water demands is a popular approach but requires knowledge of closed-loop control practice. In theory, to obtain precise closed-loop control of a system it is necessary to characterise every component in the control loop to derive the appropriate controller parameters, i.e. proportional, integral & derivative (PID) parameters in a classic PID controller. In practice this is often difficult to achieve. Empirical methods are employed to estimate the PID parameters by observing how the system performs under open-loop conditions. In this paper we present a modified PID controller, with a constrained integral function, that delivers excellent regulation of soil moisture by supplying the appropriate amount of water to meet the needs of the plant during the diurnal cycle. Furthermore, the modified PID controller responds quickly to changes in environmental conditions, including rainfall events which can result in: controller windup, under-watering and plant stress conditions. The experimental work successfully demonstrates the functionality of a constrained integral PID controller that delivers robust and precise irrigation control. Coir substrate strawberry growing trial data is also presented illustrating soil moisture control and the ability to match water deliver to solar radiation.
Vanadium—lithium in-pile loop for comprehensive tests of vanadium alloys and multipurpose coatings
NASA Astrophysics Data System (ADS)
Lyublinski, I. E.; Evtikhin, V. A.; Ivanov, V. B.; Kazakov, V. A.; Korjavin, V. M.; Markovchev, V. K.; Melder, R. R.; Revyakin, Y. L.; Shpolyanskiy, V. N.
1996-10-01
The reliable information on design and material properties of self-cooled Li sbnd Li blanket and liquid metal divertor under neutron radiation conditions can be obtained using the concept of combined technological and material in-pile tests in a vanadium—lithium loop. The method of in-pile loop tests includes studies of vanadium—base alloys resistance, weld resistance under mechanical stress, multipurpose coating formation processes and coatings' resistance under the following conditions: high temperature (600-700°C), lithium velocities up to 10 m/s, lithium with controlled concentration of impurities and technological additions, a neutron load of 0.4-0.5 MW/m 2 and level of irradiation doses up to 5 dpa. The design of such an in-pile loop is considered. The experimental data on corrosion and compatibility with lithium, mechanical properties and welding technology of the vanadium alloys, methods of coatings formation and its radiation tests in lithium environment in the BOR-60 reactor (fast neutron fluence up to 10 26 m -2, irradiation temperature range of 500-523°C) are presented and analyzed as a basis for such loop development.
The Prevalence and Use of Walking Loops in Neighborhood Parks: A National Study.
Cohen, Deborah A; Han, Bing; Evenson, Kelly R; Nagel, Catherine; McKenzie, Thomas L; Marsh, Terry; Williamson, Stephanie; Harnik, Peter
2017-02-01
Previous studies indicate that the design of streets and sidewalks can influence physical activity among residents. Park features also influence park use and park-based physical activity. Although individuals can walk on streets and sidewalks, walking loops in parks offer a setting to walk in nature and to avoid interruptions from traffic. Here we describe the use of walking loops in parks and compare the number of park users and their physical activity in urban neighborhood parks with and without walking loops. We analyzed data from the National Study of Neighborhood Parks in which a representative sample of neighborhood parks (n = 174) from 25 U.S. cities with > 100,000 population were observed systematically to document facilities and park users by age group and sex. We compared the number of people and their physical activity in parks with and without walking loops, controlling for multiple factors, including park size, facilities, and population density. Overall, compared with parks without walking loops, on average during an hourly observation, parks with walking loops had 80% more users (95% CI: 42, 139%), and levels of moderate-to-vigorous physical activity were 90% higher (95% CI: 49, 145%). The additional park use and park-based physical activity occurred not only on the walking loops but throughout the park. Walking loops may be a promising means of increasing population level physical activity. Further studies are needed to confirm a causal relationship. Citation: Cohen DA, Han B, Evenson KR, Nagel C, McKenzie TL, Marsh T, Williamson S, Harnik P. 2017. The prevalence and use of walking loops in neighborhood parks: a national study. Environ Health Perspect 125:170-174; http://dx.doi.org/10.1289/EHP293.
Sorting Rotating Micromachines by Variations in Their Magnetic Properties
NASA Astrophysics Data System (ADS)
Howell, Taylor A.; Osting, Braxton; Abbott, Jake J.
2018-05-01
We consider sorting for the broad class of micromachines (also known as microswimmers, microrobots, micropropellers, etc.) propelled by rotating magnetic fields. We present a control policy that capitalizes on the variation in magnetic properties between otherwise-homogeneous micromachines to enable the sorting of a select fraction of a group from the remainder and prescribe its net relative movement, using a uniform magnetic field that is applied equally to all micromachines. The method enables us to accomplish this sorting task using open-loop control, without relying on a structured environment or localization information of individual micromachines. With our method, the control time to perform the sort is invariant to the number of micromachines. The method is verified through simulations and scaled experiments. Finally, we include an extended discussion about the limitations of the method and address open questions related to its practical application.
Briscoe, J; Rankin, P M
2009-01-01
Children with specific language impairment (SLI) often experience difficulties in the recall and repetition of verbal information. Archibald and Gathercole (2006) suggested that children with SLI are vulnerable across two separate components of a tripartite model of working memory (Baddeley and Hitch 1974). However, the hierarchical relationship between the 'slave' systems (temporary storage) and the central executive components places a particular challenge for interpreting working memory profiles within a tripartite model. This study aimed to examine whether a 'double-jeopardy' assumption is compatible with a hierarchical relationship between the phonological loop and central executive components of the working memory model in children with SLI. If a strong double-jeopardy assumption is valid for children with SLI, it was predicted that raw scores of working memory tests thought to tap phonological loop and central executive components of tripartite working memory would be lower than the scores of children matched for chronological age and those of children matched for language level, according to independent sources of constraint. In contrast, a hierarchical relationship would imply that a weakness in a slave component of working memory (the phonological loop) would also constrain performance on tests tapping a super-ordinate component (central executive). This locus of constraint would predict that scores of children with SLI on working memory tests that tap the central executive would be weaker relative to the scores of chronological age-matched controls only. Seven subtests of the Working Memory Test Battery for Children (Digit recall, Word recall, Non-word recall, Word matching, Listening recall, Backwards digit recall and Block recall; Pickering and Gathercole 2001) were administered to 14 children with SLI recruited via language resource bases and specialist schools, as well as two control groups matched on chronological age and vocabulary level, respectively. Mean group differences were ascertained by directly comparing raw scores on memory tests linked to different components of the tripartite model using a series of multivariate analyses. The majority of working memory scores of the SLI group were depressed relative to chronological age-matched controls, with the exception of spatial recall (block tapping) and word (order) matching tasks. Marked deficits in serial recall of words and digits were evident, with the SLI group scoring more poorly than the language-ability matched control group on these measures. Impairments of the SLI group on phonological loop tasks were robust, even when covariance with executive working memory scores was accounted for. There was no robust effect of group on complex working memory (central executive) tasks, despite a slight association between listening recall and phonological loop measures. A predominant feature of the working memory profile of SLI was a marked deficit on phonological loop tasks. Although scores on complex working memory tasks were also depressed, there was little evidence for a strong interpretation of double-jeopardy within working memory profiles for these children, rather these findings were consistent with an interpretation of a constraint on phonological loop for children with SLI that operated at all levels of a hierarchical tripartite model of working memory (Baddeley and Hitch 1974). These findings imply that low scores on complex working memory tasks alone do not unequivocally imply an independent deficit in central executive (domain-general) resources of working memory and should therefore be treated cautiously in a clinical context.
Structural dynamics of the lac repressor-DNA complex revealed by a multiscale simulation.
Villa, Elizabeth; Balaeff, Alexander; Schulten, Klaus
2005-05-10
A multiscale simulation of a complex between the lac repressor protein (LacI) and a 107-bp-long DNA segment is reported. The complex between the repressor and two operator DNA segments is described by all-atom molecular dynamics; the size of the simulated system comprises either 226,000 or 314,000 atoms. The DNA loop connecting the operators is modeled as a continuous elastic ribbon, described mathematically by the nonlinear Kirchhoff differential equations with boundary conditions obtained from the coordinates of the terminal base pairs of each operator. The forces stemming from the looped DNA are included in the molecular dynamics simulations; the loop structure and the forces are continuously recomputed because the protein motions during the simulations shift the operators and the presumed termini of the loop. The simulations reveal the structural dynamics of the LacI-DNA complex in unprecedented detail. The multiple domains of LacI exhibit remarkable structural stability during the simulation, moving much like rigid bodies. LacI is shown to absorb the strain from the looped DNA mainly through its mobile DNA-binding head groups. Even with large fluctuating forces applied, the head groups tilt strongly and keep their grip on the operator DNA, while the remainder of the protein retains its V-shaped structure. A simulated opening of the cleft of LacI by 500-pN forces revealed the interactions responsible for locking LacI in the V-conformation.
Sensory feedback in prosthetics: a standardized test bench for closed-loop control.
Dosen, Strahinja; Markovic, Marko; Hartmann, Cornelia; Farina, Dario
2015-03-01
Closing the control loop by providing sensory feedback to the user of a prosthesis is an important challenge, with major impact on the future of prosthetics. Developing and comparing closed-loop systems is a difficult task, since there are many different methods and technologies that can be used to implement each component of the system. Here, we present a test bench developed in Matlab Simulink for configuring and testing the closed-loop human control system in standardized settings. The framework comprises a set of connected generic blocks with normalized inputs and outputs, which can be customized by selecting specific implementations from a library of predefined components. The framework is modular and extensible and it can be used to configure, compare and test different closed-loop system prototypes, thereby guiding the development towards an optimal system configuration. The use of the test bench was demonstrated by investigating two important aspects of closed-loop control: performance of different electrotactile feedback interfaces (spatial versus intensity coding) during a pendulum stabilization task and feedforward methods (joystick versus myocontrol) for force control. The first experiment demonstrated that in the case of trained subjects the intensity coding might be superior to spatial coding. In the second experiment, the control of force was rather poor even with a stable and precise control interface (joystick), demonstrating that inherent characteristics of the prosthesis can be an important limiting factor when considering the overall effectiveness of the closed-loop control. The presented test bench is an important instrument for investigating different aspects of human manual control with sensory feedback.
Refrigerant directly cooled capacitors
Hsu, John S [Oak Ridge, TN; Seiber, Larry E [Oak Ridge, TN; Marlino, Laura D [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN
2007-09-11
The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.
Paës, Gabriel; Cortés, Juan; Siméon, Thierry; O'Donohue, Michael J.; Tran, Vinh
2012-01-01
Dynamics is a key feature of enzyme catalysis. Unfortunately, current experimental and computational techniques do not yet provide a comprehensive understanding and description of functional macromolecular motions. In this work, we have extended a novel computational technique, which combines molecular modeling methods and robotics algorithms, to investigate functional motions of protein loops. This new approach has been applied to study the functional importance of the so-called thumb-loop in the glycoside hydrolase family 11 xylanase from Thermobacillus xylanilyticus (Tx-xyl). The results obtained provide new insight into the role of the loop in the glycosylation/deglycosylation catalytic cycle, and underline the key importance of the nature of the residue located at the tip of the thumb-loop. The effect of mutations predicted in silico has been validated by in vitro site-directed mutagenesis experiments. Overall, we propose a comprehensive model of Tx-xyl catalysis in terms of substrate and product dynamics by identifying the action of the thumb-loop motion during catalysis. PMID:24688637
Studying DNA looping by single-molecule FRET.
Le, Tung T; Kim, Harold D
2014-06-28
Bending of double-stranded DNA (dsDNA) is associated with many important biological processes such as DNA-protein recognition and DNA packaging into nucleosomes. Thermodynamics of dsDNA bending has been studied by a method called cyclization which relies on DNA ligase to covalently join short sticky ends of a dsDNA. However, ligation efficiency can be affected by many factors that are not related to dsDNA looping such as the DNA structure surrounding the joined sticky ends, and ligase can also affect the apparent looping rate through mechanisms such as nonspecific binding. Here, we show how to measure dsDNA looping kinetics without ligase by detecting transient DNA loop formation by FRET (Fluorescence Resonance Energy Transfer). dsDNA molecules are constructed using a simple PCR-based protocol with a FRET pair and a biotin linker. The looping probability density known as the J factor is extracted from the looping rate and the annealing rate between two disconnected sticky ends. By testing two dsDNAs with different intrinsic curvatures, we show that the J factor is sensitive to the intrinsic shape of the dsDNA.
Research on the man in the loop control system of the robot arm based on gesture control
NASA Astrophysics Data System (ADS)
Xiao, Lifeng; Peng, Jinbao
2017-03-01
The Man in the loop control system of the robot arm based on gesture control research complex real-world environment, which requires the operator to continuously control and adjust the remote manipulator, as the background, completes the specific mission human in the loop entire system as the research object. This paper puts forward a kind of robot arm control system of Man in the loop based on gesture control, by robot arm control system based on gesture control and Virtual reality scene feedback to enhance immersion and integration of operator, to make operator really become a part of the whole control loop. This paper expounds how to construct a man in the loop control system of the robot arm based on gesture control. The system is a complex system of human computer cooperative control, but also people in the loop control problem areas. The new system solves the problems that the traditional method has no immersion feeling and the operation lever is unnatural, the adjustment time is long, and the data glove mode wears uncomfortable and the price is expensive.
Studying DNA Looping by Single-Molecule FRET
Le, Tung T.; Kim, Harold D.
2014-01-01
Bending of double-stranded DNA (dsDNA) is associated with many important biological processes such as DNA-protein recognition and DNA packaging into nucleosomes. Thermodynamics of dsDNA bending has been studied by a method called cyclization which relies on DNA ligase to covalently join short sticky ends of a dsDNA. However, ligation efficiency can be affected by many factors that are not related to dsDNA looping such as the DNA structure surrounding the joined sticky ends, and ligase can also affect the apparent looping rate through mechanisms such as nonspecific binding. Here, we show how to measure dsDNA looping kinetics without ligase by detecting transient DNA loop formation by FRET (Fluorescence Resonance Energy Transfer). dsDNA molecules are constructed using a simple PCR-based protocol with a FRET pair and a biotin linker. The looping probability density known as the J factor is extracted from the looping rate and the annealing rate between two disconnected sticky ends. By testing two dsDNAs with different intrinsic curvatures, we show that the J factor is sensitive to the intrinsic shape of the dsDNA. PMID:24998459
2018-01-01
CTCF and cohesin are key drivers of 3D-nuclear organization, anchoring the megabase-scale Topologically Associating Domains (TADs) that segment the genome. Here, we present and validate a computational method to predict cohesin-and-CTCF binding sites that form intra-TAD DNA loops. The intra-TAD loop anchors identified are structurally indistinguishable from TAD anchors regarding binding partners, sequence conservation, and resistance to cohesin knockdown; further, the intra-TAD loops retain key functional features of TADs, including chromatin contact insulation, blockage of repressive histone mark spread, and ubiquity across tissues. We propose that intra-TAD loops form by the same loop extrusion mechanism as the larger TAD loops, and that their shorter length enables finer regulatory control in restricting enhancer-promoter interactions, which enables selective, high-level expression of gene targets of super-enhancers and genes located within repressive nuclear compartments. These findings elucidate the role of intra-TAD cohesin-and-CTCF binding in nuclear organization associated with widespread insulation of distal enhancer activity. PMID:29757144
Matthews, Bryan J; Waxman, David J
2018-05-14
CTCF and cohesin are key drivers of 3D-nuclear organization, anchoring the megabase-scale Topologically Associating Domains (TADs) that segment the genome. Here, we present and validate a computational method to predict cohesin-and-CTCF binding sites that form intra-TAD DNA loops. The intra-TAD loop anchors identified are structurally indistinguishable from TAD anchors regarding binding partners, sequence conservation, and resistance to cohesin knockdown; further, the intra-TAD loops retain key functional features of TADs, including chromatin contact insulation, blockage of repressive histone mark spread, and ubiquity across tissues. We propose that intra-TAD loops form by the same loop extrusion mechanism as the larger TAD loops, and that their shorter length enables finer regulatory control in restricting enhancer-promoter interactions, which enables selective, high-level expression of gene targets of super-enhancers and genes located within repressive nuclear compartments. These findings elucidate the role of intra-TAD cohesin-and-CTCF binding in nuclear organization associated with widespread insulation of distal enhancer activity. © 2018, Matthews et al.
Structure and Dynamics Analysis on Plexin-B1 Rho GTPase Binding Domain as a Monomer and Dimer
2015-01-01
Plexin-B1 is a single-pass transmembrane receptor. Its Rho GTPase binding domain (RBD) can associate with small Rho GTPases and can also self-bind to form a dimer. In total, more than 400 ns of NAMD molecular dynamics simulations were performed on RBD monomer and dimer. Different analysis methods, such as root mean squared fluctuation (RMSF), order parameters (S2), dihedral angle correlation, transfer entropy, principal component analysis, and dynamical network analysis, were carried out to characterize the motions seen in the trajectories. RMSF results show that after binding, the L4 loop becomes more rigid, but the L2 loop and a number of residues in other regions become slightly more flexible. Calculating order parameters (S2) for CH, NH, and CO bonds on both backbone and side chain shows that the L4 loop becomes essentially rigid after binding, but part of the L1 loop becomes slightly more flexible. Backbone dihedral angle cross-correlation results show that loop regions such as the L1 loop including residues Q25 and G26, the L2 loop including residue R61, and the L4 loop including residues L89–R91, are highly correlated compared to other regions in the monomer form. Analysis of the correlated motions at these residues, such as Q25 and R61, indicate two signal pathways. Transfer entropy calculations on the RBD monomer and dimer forms suggest that the binding process should be driven by the L4 loop and C-terminal. However, after binding, the L4 loop functions as the motion responder. The signal pathways in RBD were predicted based on a dynamical network analysis method using the pathways predicted from the dihedral angle cross-correlation calculations as input. It is found that the shortest pathways predicted from both inputs can overlap, but signal pathway 2 (from F90 to R61) is more dominant and overlaps all of the routes of pathway 1 (from F90 to P111). This project confirms the allosteric mechanism in signal transmission inside the RBD network, which was in part proposed in the previous experimental study. PMID:24901636
Strings in bubbling geometries and dual Wilson loop correlators
NASA Astrophysics Data System (ADS)
Aguilera-Damia, Jeremías; Correa, Diego H.; Fucito, Francesco; Giraldo-Rivera, Victor I.; Morales, Jose F.; Pando Zayas, Leopoldo A.
2017-12-01
We consider a fundamental string in a bubbling geometry of arbitrary genus dual to a half-supersymmetric Wilson loop in a general large representation R of the SU( N) gauge group in N=4 Supersymmetric Yang-Mills. We demonstrate, under some mild conditions, that the minimum value of the string classical action for a bubbling geometry of arbitrary genus precisely matches the correlator of a Wilson loop in the fundamental representation and one in a general large representation. We work out the case in which the large representation is given by a rectangular Young tableau, corresponding to a genus one bubbling geometry, explicitly. We also present explicit results in the field theory for a correlator of two Wilson loops: a large one in an arbitrary representation and a "small" one in the fundamental, totally symmetric or totally antisymmetric representation.
A functional renormalization method for wave propagation in random media
NASA Astrophysics Data System (ADS)
Lamagna, Federico; Calzetta, Esteban
2017-08-01
We develop the exact renormalization group approach as a way to evaluate the effective speed of the propagation of a scalar wave in a medium with random inhomogeneities. We use the Martin-Siggia-Rose formalism to translate the problem into a non equilibrium field theory one, and then consider a sequence of models with a progressively lower infrared cutoff; in the limit where the cutoff is removed we recover the problem of interest. As a test of the formalism, we compute the effective dielectric constant of an homogeneous medium interspersed with randomly located, interpenetrating bubbles. A simple approximation to the renormalization group equations turns out to be equivalent to a self-consistent two-loops evaluation of the effective dielectric constant.
Lee, Sang Ki; Hwang, Yoon Sub; Choy, Won Sik
2014-03-01
Conventional operative treatments of patella fractures are frequently associated with implant failure or displacement. Recent biomechanical studies showed that the orientation of the wire loop and the site of the wire twist can affect the fixation strength. The purpose of this study was to compare the clinical outcome of the tension band technique with loops in different orientations and different knot positions. For this retrospective study, 72 patella fractures (71 patients) were fixed with figure-of-eight configurations in combination with 2 K-wires. Patients were divided into 3 groups according to the orientation of tension band construct. A total of 40 patella fractures were placed with figure-of-eight configurations in a vertical orientation either with 1 wire twist (group 1; 16 patella fractures) or with 2 wire twists at the adjacent corners (group 2; 24 patella fractures). Thirty-two patella fractures were placed with figure-of-eight configurations in a horizontal orientation with 2 wire twists at the adjacent corners (group 3). Range of motion, complication rates, and knee scoring scales (Hospital for Special Surgery and Lysholm) were assessed during serial follow-up. Satisfactory reductions were achieved in all groups, but functional results in the early stage were different. Group 3 had better Hospital for Special Surgery and Lysholm scores at 3 months postoperatively; however, at 6 months and 1 year postoperatively, all groups had similar scores. At the 1-year follow-up, all groups achieved acceptable flexion and range of motion. The overall complication rate was lower in the horizontal group (12.5%). Placing the figure-of-eight tension band construct in a horizontal orientation can provide functional benefits in the early stage after patella fractures. Copyright 2014, SLACK Incorporated.
Immirzi parameter without Immirzi ambiguity: Conformal loop quantization of scalar-tensor gravity
NASA Astrophysics Data System (ADS)
Veraguth, Olivier J.; Wang, Charles H.-T.
2017-10-01
Conformal loop quantum gravity provides an approach to loop quantization through an underlying conformal structure i.e. conformally equivalent class of metrics. The property that general relativity itself has no conformal invariance is reinstated with a constrained scalar field setting the physical scale. Conformally equivalent metrics have recently been shown to be amenable to loop quantization including matter coupling. It has been suggested that conformal geometry may provide an extended symmetry to allow a reformulated Immirzi parameter necessary for loop quantization to behave like an arbitrary group parameter that requires no further fixing as its present standard form does. Here, we find that this can be naturally realized via conformal frame transformations in scalar-tensor gravity. Such a theory generally incorporates a dynamical scalar gravitational field and reduces to general relativity when the scalar field becomes a pure gauge. In particular, we introduce a conformal Einstein frame in which loop quantization is implemented. We then discuss how different Immirzi parameters under this description may be related by conformal frame transformations and yet share the same quantization having, for example, the same area gaps, modulated by the scalar gravitational field.
Apparatus for and method of monitoring for breached fuel elements
Gross, K.C.; Strain, R.V.
1981-04-28
This invention teaches improved apparatus for the method of detecting a breach in cladded fuel used in a nuclear reactor. The detector apparatus uses a separate bypass loop for conveying part of the reactor coolant away from the core, and at least three separate delayed-neutron detectors mounted proximate this detector loop. The detectors are spaced apart so that the coolant flow time from the core to each detector is different, and these differences are known. The delayed-neutron activity at the detectors is a function of the delay time after the reaction in the fuel until the coolant carrying the delayed-neutron emitter passes the respective detector. This time delay is broken down into separate components including an isotopic holdup time required for the emitter to move through the fuel from the reaction to the coolant at the breach, and two transit times required for the emitter now in the coolant to flow from the breach to the detector loop and then via the loop to the detector.
Tao, Chenyu; Zhang, Qingde; Zhai, Shanli; Liu, Bang
2013-11-01
In this study, sensitive and rapid detection systems were designed using a loop-mediated isothermal amplification (LAMP) method to detect the genetically modified goats. A set of 4 primers were designed for each exogenous nucleic acids HBsAg and hATIII. The DNA samples were first amplified with the outer and inner primers and released a single-stranded DNA,of which both ends were stem-loop structure. Then one inner primer hybridized with the loop, and initiated displacement synthesis in less than 1 h. The result could be visualized by both agarose gel electrophoresis and unaided eyes directly after adding SYBR GREEN 1. The detection limit of LAMP was ten copies of target molecules, indicating that LAMP was tenfold more sensitive than the classical PCR. Furthermore, all the samples of genetically modified goats were tested positively by LAMP, and the results demonstrated that the LAMP was a rapid and sensitive method for detecting the genetically modified organism.
Diagonal dominance for the multivariable Nyquist array using function minimization
NASA Technical Reports Server (NTRS)
Leininger, G. G.
1977-01-01
A new technique for the design of multivariable control systems using the multivariable Nyquist array method was developed. A conjugate direction function minimization algorithm is utilized to achieve a diagonal dominant condition over the extended frequency range of the control system. The minimization is performed on the ratio of the moduli of the off-diagonal terms to the moduli of the diagonal terms of either the inverse or direct open loop transfer function matrix. Several new feedback design concepts were also developed, including: (1) dominance control parameters for each control loop; (2) compensator normalization to evaluate open loop conditions for alternative design configurations; and (3) an interaction index to determine the degree and type of system interaction when all feedback loops are closed simultaneously. This new design capability was implemented on an IBM 360/75 in a batch mode but can be easily adapted to an interactive computer facility. The method was applied to the Pratt and Whitney F100 turbofan engine.
A closed-loop photon beam control study for the Advanced Light Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Portmann, G.; Bengtsson, J.
1993-05-01
The third generation Advanced Light Source (ALS) will produce extremely bright photon beams using undulators and wigglers. In order to position the photon beams accurate to the micron level, a closed-loop feedback system is being developed. Using photon position monitors and dipole corrector magnets, a closed-loop system can automatically compensate for modeling uncertainties and exogenous disturbances. The following paper will present a dynamics model for the perturbations of the closed orbit of the electron beam in the ALS storage ring including the vacuum chamber magnetic field penetration effects. Using this reference model, two closed-loop feedback algorithms will be compared --more » a classical PI controller and a two degree-of-freedom approach. The two degree-of-freedom method provides superior disturbance rejection while maintaining the desired performance goals. Both methods will address the need to gain schedule the controller due to the time varying dynamics introduced by changing field strengths when scanning the insertion devices.« less
Closed-Loop Process Control for Electron Beam Freeform Fabrication and Deposition Processes
NASA Technical Reports Server (NTRS)
Taminger, Karen M. (Inventor); Hofmeister, William H. (Inventor); Martin, Richard E. (Inventor); Hafley, Robert A. (Inventor)
2013-01-01
A closed-loop control method for an electron beam freeform fabrication (EBF(sup 3)) process includes detecting a feature of interest during the process using a sensor(s), continuously evaluating the feature of interest to determine, in real time, a change occurring therein, and automatically modifying control parameters to control the EBF(sup 3) process. An apparatus provides closed-loop control method of the process, and includes an electron gun for generating an electron beam, a wire feeder for feeding a wire toward a substrate, wherein the wire is melted and progressively deposited in layers onto the substrate, a sensor(s), and a host machine. The sensor(s) measure the feature of interest during the process, and the host machine continuously evaluates the feature of interest to determine, in real time, a change occurring therein. The host machine automatically modifies control parameters to the EBF(sup 3) apparatus to control the EBF(sup 3) process in a closed-loop manner.
Analysis and Design of a Speed and Position System for Maglev Vehicles
Dai, Chunhui; Dou, Fengshan; Song, Xianglei; Long, Zhiqiang
2012-01-01
This paper mainly researches one method of speed and location detection for maglev vehicles. As the maglev train doesn't have any physical contact with the rails, it has to use non-contact measuring methods. The technology based on the inductive loop-cable could fulfill the requirement by using an on-board antenna which could detect the alternating magnetic field produced by the loop-cable on rails. This paper introduces the structure of a speed and position system, and analyses the electromagnetic field produced by the loop-cable. The equivalent model of the loop-cable is given and the most suitable component of the magnetic flux density is selected. Then the paper also compares the alternating current (AC) resistance and the quality factor between two kinds of coils which the antenna is composed of. The effect of the rails to the signal receiving is also researched and then the structure of the coils is improved. Finally, considering the common-mode interference, 8-word coils are designed and analyzed. PMID:23012504
Analysis and design of a speed and position system for maglev vehicles.
Dai, Chunhui; Dou, Fengshan; Song, Xianglei; Long, Zhiqiang
2012-01-01
This paper mainly researches one method of speed and location detection for maglev vehicles. As the maglev train doesn't have any physical contact with the rails, it has to use non-contact measuring methods. The technology based on the inductive loop-cable could fulfill the requirement by using an on-board antenna which could detect the alternating magnetic field produced by the loop-cable on rails. This paper introduces the structure of a speed and position system, and analyses the electromagnetic field produced by the loop-cable. The equivalent model of the loop-cable is given and the most suitable component of the magnetic flux density is selected. Then the paper also compares the alternating current (AC) resistance and the quality factor between two kinds of coils which the antenna is composed of. The effect of the rails to the signal receiving is also researched and then the structure of the coils is improved. Finally, considering the common-mode interference, 8-word coils are designed and analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knížat, Branislav, E-mail: branislav.knizat@stuba.sk; Urban, František, E-mail: frantisek.urban@stuba.sk; Mlkvik, Marek, E-mail: marek.mlkvik@stuba.sk
A natural circulation helium loop appears to be a perspective passive method of a nuclear reactor cooling. When designing this device, it is important to analyze the mechanism of an internal flow. The flow of helium in the loop is set in motion due to a difference of hydrostatic pressures between cold and hot branch. Steady flow at a requested flow rate occurs when the buoyancy force is adjusted to resistances against the flow. Considering the fact that the buoyancy force is proportional to a difference of temperatures in both branches, it is important to estimate the losses correctly inmore » the process of design. The paper deals with the calculation of losses in branches of the natural circulation helium loop by methods of CFD. The results of calculations are an important basis for the hydraulic design of both exchangers (heater and cooler). The analysis was carried out for the existing model of a helium loop of the height 10 m and nominal heat power 250 kW.« less
High-throughput sample adaptive offset hardware architecture for high-efficiency video coding
NASA Astrophysics Data System (ADS)
Zhou, Wei; Yan, Chang; Zhang, Jingzhi; Zhou, Xin
2018-03-01
A high-throughput hardware architecture for a sample adaptive offset (SAO) filter in the high-efficiency video coding video coding standard is presented. First, an implementation-friendly and simplified bitrate estimation method of rate-distortion cost calculation is proposed to reduce the computational complexity in the mode decision of SAO. Then, a high-throughput VLSI architecture for SAO is presented based on the proposed bitrate estimation method. Furthermore, multiparallel VLSI architecture for in-loop filters, which integrates both deblocking filter and SAO filter, is proposed. Six parallel strategies are applied in the proposed in-loop filters architecture to improve the system throughput and filtering speed. Experimental results show that the proposed in-loop filters architecture can achieve up to 48% higher throughput in comparison with prior work. The proposed architecture can reach a high-operating clock frequency of 297 MHz with TSMC 65-nm library and meet the real-time requirement of the in-loop filters for 8 K × 4 K video format at 132 fps.
ALARA: The next link in a chain of activation codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, P.P.H.; Henderson, D.L.
1996-12-31
The Adaptive Laplace and Analytic Radioactivity Analysis [ALARA] code has been developed as the next link in the chain of DKR radioactivity codes. Its methods address the criticisms of DKR while retaining its best features. While DKR ignored loops in the transmutation/decay scheme to preserve the exactness of the mathematical solution, ALARA incorporates new computational approaches without jeopardizing the most important features of DKR`s physical modelling and mathematical methods. The physical model uses `straightened-loop, linear chains` to achieve the same accuracy in the loop solutions as is demanded in the rest of the scheme. In cases where a chain hasmore » no loops, the exact DKR solution is used. Otherwise, ALARA adaptively chooses between a direct Laplace inversion technique and a Laplace expansion inversion technique to optimize the accuracy and speed of the solution. All of these methods result in matrix solutions which allow the fastest and most accurate solution of exact pulsing histories. Since the entire history is solved for each chain as it is created, ALARA achieves the optimum combination of high accuracy, high speed and low memory usage. 8 refs., 2 figs.« less
Liu, Kai; Cui, Meng-Ying; Cao, Peng; Wang, Jiang-Bo
2016-01-01
On urban arterials, travel time estimation is challenging especially from various data sources. Typically, fusing loop detector data and probe vehicle data to estimate travel time is a troublesome issue while considering the data issue of uncertain, imprecise and even conflicting. In this paper, we propose an improved data fusing methodology for link travel time estimation. Link travel times are simultaneously pre-estimated using loop detector data and probe vehicle data, based on which Bayesian fusion is then applied to fuse the estimated travel times. Next, Iterative Bayesian estimation is proposed to improve Bayesian fusion by incorporating two strategies: 1) substitution strategy which replaces the lower accurate travel time estimation from one sensor with the current fused travel time; and 2) specially-designed conditions for convergence which restrict the estimated travel time in a reasonable range. The estimation results show that, the proposed method outperforms probe vehicle data based method, loop detector based method and single Bayesian fusion, and the mean absolute percentage error is reduced to 4.8%. Additionally, iterative Bayesian estimation performs better for lighter traffic flows when the variability of travel time is practically higher than other periods.
Cui, Meng-Ying; Cao, Peng; Wang, Jiang-Bo
2016-01-01
On urban arterials, travel time estimation is challenging especially from various data sources. Typically, fusing loop detector data and probe vehicle data to estimate travel time is a troublesome issue while considering the data issue of uncertain, imprecise and even conflicting. In this paper, we propose an improved data fusing methodology for link travel time estimation. Link travel times are simultaneously pre-estimated using loop detector data and probe vehicle data, based on which Bayesian fusion is then applied to fuse the estimated travel times. Next, Iterative Bayesian estimation is proposed to improve Bayesian fusion by incorporating two strategies: 1) substitution strategy which replaces the lower accurate travel time estimation from one sensor with the current fused travel time; and 2) specially-designed conditions for convergence which restrict the estimated travel time in a reasonable range. The estimation results show that, the proposed method outperforms probe vehicle data based method, loop detector based method and single Bayesian fusion, and the mean absolute percentage error is reduced to 4.8%. Additionally, iterative Bayesian estimation performs better for lighter traffic flows when the variability of travel time is practically higher than other periods. PMID:27362654
A direct method for calculating instrument noise levels in side-by-side seismometer evaluations
Holcomb, L. Gary
1989-01-01
The subject of determining the inherent system noise levels present in modem broadband closed loop seismic sensors has been an evolving topic ever since closed loop systems became available. Closed loop systems are unique in that the system noise can not be determined via a blocked mass test as in older conventional open loop seismic sensors. Instead, most investigators have resorted to performing measurements on two or more systems operating in close proximity to one another and to analyzing the outputs of these systems with respect to one another to ascertain their relative noise levels.The analysis of side-by-side relative performance is inherently dependent on the accuracy of the mathematical modeling of the test configuration. This report presents a direct approach to extracting the system noise levels of two linear systems with a common coherent input signal. The mathematical solution to the problem is incredibly simple; however the practical application of the method encounters some difficulties. Examples of expected accuracies are presented as derived by simulating real systems performance using computer generated random noise. In addition, examples of the performance of the method when applied to real experimental test data are shown.
Relative stability of the open and closed conformations of the active site loop of streptavidin
NASA Astrophysics Data System (ADS)
Ignacio J., General; Meirovitch, Hagai
2011-01-01
The eight-residue surface loop, 45-52 (Ser, Ala, Val, Gly, Asn, Ala, Glu, Ser), of the homotetrameric protein streptavidin has a "closed" conformation in the streptavidin-biotin complex, where the corresponding binding affinity is one of the strongest found in nature (ΔG ˜ -18 kcal/mol). However, in most of the crystal structures of apo (unbound) streptavidin, the loop conformation is "open" and typically exhibits partial disorder and high B-factors. Thus, it is plausible to assume that the loop structure is changed from open to closed upon binding of biotin, and the corresponding difference in free energy, ΔF = Fopen - Fclosed in the unbound protein, should therefore be considered in the total absolute free energy of binding. ΔF (which has generally been neglected) is calculated here using our "hypothetical scanning molecular-dynamics" (HSMD) method. We use a protein model in which only the atoms closest to the loop are considered (the "template") and they are fixed in the x-ray coordinates of the free protein; the x-ray conformation of the closed loop is attached to the same (unbound) template and both systems are capped with the same sphere of TIP3P water. Using the force field of the assisted model building with energy refinement (AMBER), we carry out two separate MD simulations (at temperature T = 300 K), starting from the open and closed conformations, where only the atoms of the loop and water are allowed to move (the template-water and template-loop interactions are considered). The absolute Fopen and Fclosed (of loop + water) are calculated from these trajectories, where the loop and water contributions are obtained by HSMD and a thermodynamic integration (TI) process, respectively. The combined HSMD-TI procedure leads to total (loop + water) ΔF = -27.1 ± 2.0 kcal/mol, where the entropy TΔS constitutes 34% of ΔF, meaning that the effect of S is significant and should not be ignored. Also, ΔS is positive, in accord with the high flexibility of the open loop observed in crystal structures, while the energy ΔE is unexpectedly negative, thus also adding to the stability of the open loop. The loop and the 250 capped water molecules are the largest system studied thus far, which constitutes a test for the efficiency of HSMD-TI; this efficiency and technical issues related to the implementation of the method are also discussed. Finally, the result for ΔF is a prediction that will be considered in the calculation of the absolute free energy of binding of biotin to streptavidin, which constitutes our next project.
Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan
2013-11-01
The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg(-1) GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25.
Loop-mediated isothermal amplification (LAMP) method for detection of genetically modified maize T25
Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan
2013-01-01
The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg−1 GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25. PMID:24804053
Markov chain sampling of the O(n) loop models on the infinite plane
NASA Astrophysics Data System (ADS)
Herdeiro, Victor
2017-07-01
A numerical method was recently proposed in Herdeiro and Doyon [Phys. Rev. E 94, 043322 (2016), 10.1103/PhysRevE.94.043322] showing a precise sampling of the infinite plane two-dimensional critical Ising model for finite lattice subsections. The present note extends the method to a larger class of models, namely the O(n) loop gas models for n ∈(1 ,2 ] . We argue that even though the Gibbs measure is nonlocal, it is factorizable on finite subsections when sufficient information on the loops touching the boundaries is stored. Our results attempt to show that provided an efficient Markov chain mixing algorithm and an improved discrete lattice dilation procedure the planar limit of the O(n) models can be numerically studied with efficiency similar to the Ising case. This confirms that scale invariance is the only requirement for the present numerical method to work.
Usharani, Dandamudi; Srivani, Palakuri; Sastry, G Narahari; Jemmis, Eluvathingal D
2008-06-01
Available X-ray crystal structures of phosphodiesterase 4 (PDE 4) are classified into two groups based on a secondary structure difference of a 310-helix versus a turn in the M-loop region. The only variable that was discernible between these two sets is the pH at the crystallization conditions. Assuming that at lower pH there is a possibility of protonation, thermodynamics of protonation and deprotonation of the aspartic acid, cysteine side chains, and amide bonds are calculated. The models in the gas phase and in the explicit solvent using the ONIOM method are calculated at the B3LYP/6-31+G* and B3LYP/6-31+G*:UFF levels of theory, respectively. The molecular dynamics (MD) simulations are also performed on the M-loop region of a 310-helix and a turn with explicit water for 10 ns under NPT conditions. The isodesmic equations of the various protonation states show that the turn containing structure is thermodynamically more stable when proline or cysteine is protonated. The preference for the turn structure on protonation (pH = 6.5-7.5) is due to an increase in the number of the hydrogen bonding and electrostatic interactions gained by the surrounding environment such as adjacent residues and solvent molecules.
Spectral asymptotics of Euclidean quantum gravity with diff-invariant boundary conditions
NASA Astrophysics Data System (ADS)
Esposito, Giampiero; Fucci, Guglielmo; Kamenshchik, Alexander Yu; Kirsten, Klaus
2005-03-01
A general method is known to exist for studying Abelian and non-Abelian gauge theories, as well as Euclidean quantum gravity, at 1-loop level on manifolds with boundary. In the latter case, boundary conditions on metric perturbations h can be chosen to be completely invariant under infinitesimal diffeomorphisms, to preserve the invariance group of the theory and BRST symmetry. In the de Donder gauge, however, the resulting boundary-value problem for the Laplace-type operator acting on h is known to be self-adjoint but not strongly elliptic. The latter is a technical condition ensuring that a unique smooth solution of the boundary-value problem exists, which implies, in turn, that the global heat-kernel asymptotics yielding 1-loop divergences and 1-loop effective action actually exists. The present paper shows that, on the Euclidean 4-ball, only the scalar part of perturbative modes for quantum gravity is affected by the lack of strong ellipticity. Further evidence for lack of strong ellipticity, from an analytic point of view, is therefore obtained. Interestingly, three sectors of the scalar-perturbation problem remain elliptic, while lack of strong ellipticity is 'confined' to the remaining fourth sector. The integral representation of the resulting ζ-function asymptotics on the Euclidean 4-ball is also obtained; this remains regular at the origin by virtue of a spectral identity here obtained for the first time.
On distributed wavefront reconstruction for large-scale adaptive optics systems.
de Visser, Cornelis C; Brunner, Elisabeth; Verhaegen, Michel
2016-05-01
The distributed-spline-based aberration reconstruction (D-SABRE) method is proposed for distributed wavefront reconstruction with applications to large-scale adaptive optics systems. D-SABRE decomposes the wavefront sensor domain into any number of partitions and solves a local wavefront reconstruction problem on each partition using multivariate splines. D-SABRE accuracy is within 1% of a global approach with a speedup that scales quadratically with the number of partitions. The D-SABRE is compared to the distributed cumulative reconstruction (CuRe-D) method in open-loop and closed-loop simulations using the YAO adaptive optics simulation tool. D-SABRE accuracy exceeds CuRe-D for low levels of decomposition, and D-SABRE proved to be more robust to variations in the loop gain.
Golub, Ilya; Exir, Hourieh
2013-05-01
We present a left-right symmetry restoring method, which removes the detrimental birefringence in the single-mode fiber Sagnac interferometer, achieved with the aid of a half waveplate oriented at a specific angle. We show theoretically and demonstrate experimentally that adding a π-shift between clockwise and counterclockwise propagating, horizontally (in fiber loop plane) polarized field components, the Sagnac loop mirror's reflection becomes independent on birefringence of an element placed in the loop.
Development and Implementation of a Design Metric for Systems Containing Long-Term Fluid Loops
NASA Technical Reports Server (NTRS)
Steele, John W.
2016-01-01
John Steele, a chemist and technical fellow from United Technologies Corporation, provided a water quality module to assist engineers and scientists with a metric tool to evaluate risks associated with the design of space systems with fluid loops. This design metric is a methodical, quantitative, lessons-learned based means to evaluate the robustness of a long-term fluid loop system design. The tool was developed by a cross-section of engineering disciplines who had decades of experience and problem resolution.
NNLO splitting and coefficient functions with time-like kinematics
NASA Astrophysics Data System (ADS)
Mitov, A.; Moch, S.; Vogt, A.
2006-10-01
We discuss recent results on the three-loop (next-to-next-to-leading order, NNLO) time-like splitting functions of QCD and the two-loop (NNLO) coefficient functions in one-particle inclusive e+e--annihilation. These results form the basis for extracting fragmentation functions for light and heavy flavors with NNLO accuracy that will be needed at the LHC and ILC. The two-loop calculations have been performed in Mellin space based on a new method, the main features of which we also describe briefly.
The Performance of A Sampled Data Delay Lock Loop Implemented with a Kalman Loop Filter.
1980-01-01
que for analysis is computer simulation. Other techniques include state variable techniques and z-transform methods. Since the Kalman filter is linear...LOGIC NOT SHOWN Figure 2. Block diagram of the sampled data delay lock loop (SDDLL) Es A/ A 3/A/ Figure 3. Sampled error voltage ( Es ) as a function of...from a sum of two components. The first component is the previous filtered es - timate advanced one step forward by the state transition matrix. The 8
Quantitative Feedback Technique (QFT): Bridging the Gap
2003-05-01
with Eq. (2) illustrates: (a) the effect of changes of the uncertainty set P(s) upon the output of the closed -loop control system is reduced by the...Bridging the Gap root-locus technique the dominant closed -loop poles are determined for a ζ= 0.45. Table 3 presents the required value of Kx and...degree of decoupling will have been enhanced. Method 1 is then more readily applicable, with the additional benefit of reduced closed -loop BW. E.R.2
Kuntanapreeda, S; Fullmer, R R
1996-01-01
A training method for a class of neural network controllers is presented which guarantees closed-loop system stability. The controllers are assumed to be nonlinear, feedforward, sampled-data, full-state regulators implemented as single hidden-layer neural networks. The controlled systems must be locally hermitian and observable. Stability of the closed-loop system is demonstrated by determining a Lyapunov function, which can be used to identify a finite stability region about the regulator point.
Bougie, Daniel W; Peterson, Julie A; Kanack, Adam J; Curtis, Brian R; Aster, Richard H
2014-01-01
Background HNA-3a specific antibodies can cause severe, sometimes fatal, transfusion related acute lung injury (TRALI) when present in transfused blood. The HNA3-a/b antigens are determined by an R154Q polymorphism in the first of five extracellular loops of the 10-membrane spanning choline transporter-like protein 2 (CTL2) expressed on neutrophils, lymphocytes and other tissues. About 50% of HNA-3a antibodies (Type 1) can be detected using CTL2 Loop 1 peptides containing R154; the remaining 50% (Type 2) fail to recognize this target. Understanding the basis for this difference could guide efforts to develop practical assays to screen blood donors for HNA-3 antibodies. Study design and methods Reactions of HNA-3a antibodies against recombinant versions of human, mouse, and human/mouse (chimeric) CTL2 were characterized using flow cytometry and various solid phase assays. Results Findings made show that, for binding to CTL2, Type 2 HNA-3a antibodies require non-polymorphic amino acid residues in the third, and possibly the second, extracellular loops of CTL2 to be in a configuration comparable to that found naturally in the cell membrane. In contrast, Type 1 antibodies require only peptides from the first extracellular loop that contain R154 for recognition. Conclusion Although Type 1 HNA-3a antibodies can readily be detected in solid phase assays that use a CTL2 peptide containing R154 as a target, development of a practical test to screen blood donors for Type 2 antibodies will pose a serious technical challenge because of the complex nature of the epitope(s) recognized by this antibody sub-group. PMID:24846273
Hanaoka, Nozomu; Matsutani, Minenosuke; Satoh, Masaaki; Ogawa, Motohiko; Shirai, Mutsunori; Ando, Shuji
2017-01-24
We developed a novel loop-mediated isothermal amplification (LAMP) method to detect Rickettsia spp., including Rickettsia prowazekii and R. typhi. Species-specific LAMP primers were developed for orthologous genes conserved among Rickettsia spp. The selected modified primers could detect all the Rickettsia spp. tested. The LAMP method was successfully used to detect 100 DNA copies of Rickettsia spp. within approximately 60 min at 63℃. Therefore, this method may be an excellent tool for the early diagnosis of rickettsiosis in a laboratory or in the field.
47 CFR 51.232 - Binder group management.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Binder group management. 51.232 Section 51.232 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.232 Binder group management. (a) With the exception of loops...
All-digital signal-processing open-loop fiber-optic gyroscope with enlarged dynamic range.
Wang, Qin; Yang, Chuanchuan; Wang, Xinyue; Wang, Ziyu
2013-12-15
We propose and realize a new open-loop fiber-optic gyroscope (FOG) with an all-digital signal-processing (DSP) system where an all-digital phase-locked loop is employed for digital demodulation to eliminate the variation of the source intensity and suppress the bias drift. A Sagnac phase-shift tracking method is proposed to enlarge the dynamic range, and, with its aid, a new open-loop FOG, which can achieve a large dynamic range and high sensitivity at the same time, is realized. The experimental results show that compared with the conventional open-loop FOG with the same fiber coil and optical devices, the proposed FOG reduces the bias instability from 0.259 to 0.018 deg/h, and the angle random walk from 0.031 to 0.006 deg/h(1/2), moreover, enlarges the dynamic range to ±360 deg/s, exceeding the maximum dynamic range ±63 deg/s of the conventional open-loop FOG.
Kissing loop interaction in adenine riboswitch: insights from umbrella sampling simulations.
Di Palma, Francesco; Bottaro, Sandro; Bussi, Giovanni
2015-01-01
Riboswitches are cis-acting regulatory RNA elements prevalently located in the leader sequences of bacterial mRNA. An adenine sensing riboswitch cis-regulates adeninosine deaminase gene (add) in Vibrio vulnificus. The structural mechanism regulating its conformational changes upon ligand binding mostly remains to be elucidated. In this open framework it has been suggested that the ligand stabilizes the interaction of the distal "kissing loop" complex. Using accurate full-atom molecular dynamics with explicit solvent in combination with enhanced sampling techniques and advanced analysis methods it could be possible to provide a more detailed perspective on the formation of these tertiary contacts. In this work, we used umbrella sampling simulations to study the thermodynamics of the kissing loop complex in the presence and in the absence of the cognate ligand. We enforced the breaking/formation of the loop-loop interaction restraining the distance between the two loops. We also assessed the convergence of the results by using two alternative initialization protocols. A structural analysis was performed using a novel approach to analyze base contacts. Contacts between the two loops were progressively lost when larger inter-loop distances were enforced. Inter-loop Watson-Crick contacts survived at larger separation when compared with non-canonical pairing and stacking interactions. Intra-loop stacking contacts remained formed upon loop undocking. Our simulations qualitatively indicated that the ligand could stabilize the kissing loop complex. We also compared with previously published simulation studies. Kissing complex stabilization given by the ligand was compatible with available experimental data. However, the dependence of its value on the initialization protocol of the umbrella sampling simulations posed some questions on the quantitative interpretation of the results and called for better converged enhanced sampling simulations.
Pan, Qunxing; He, Kongwang; Wang, Yongshan; Wang, Xiaoli; Ouyang, Wei
2013-06-01
An antigen-delivery system based on hybrid virus-like particles (VLPs) formed by the self-assembly of the capsid VP2 protein of porcine parvovirus (PPV) and expressing foreign peptides offers an alternative method for vaccination. In this study, the three-dimensional structure of the PPV capsid protein and surface loops deletion mutants were analyzed to define essential domains in PPV VP2 for the assembly of VLPs. Electron microscopic analysis and SDS-PAGE analysis confirmed the presence of abundant VLPs in a loop2 deletion mutant of expected size and appropriate morphology. Loop4 and loop2-loop4 deletion mutants, however, resulted in a lower number of particles and the morphology of the particles was not well preserved. Furthermore, the green fluorescent protein (gfp) gene was used as a model. GFP was observed at the same level in displacements mutants. However, GFP displacement mutants in loop2 construct allowed better adaptation for the fusion GFP to be further displayed on the surface of the capsid-like structure. Immunogenicity study showed that there is no obvious difference in mice inoculated with rAd-VP2(Δloop2), rAd-VP2(Δloop4), rAd-VP2(Δloop2-Δloop4), and PPV inactivated vaccine. The results suggested the possibility of inserting simultaneously B and T cell epitopes in the surface loop2 and the N-terminus. The combination of different types of epitopes (B, CD4+, and CD8+) in different positions of the PPV particles opens the way to the development of highly efficient vaccines, able to stimulate at the same time the different branches of the immune system.
Interaction of irradiation-induced prismatic dislocation loops with free surfaces in tungsten
NASA Astrophysics Data System (ADS)
Fikar, Jan; Gröger, Roman; Schäublin, Robin
2017-02-01
The prismatic dislocation loops appear in metals as a result of high-energy irradiation. Understanding their formation and interaction is important for quantification of irradiation-induced deterioration of mechanical properties. Characterization of dislocation loops in thin foils is commonly made using transmission electron microscopy (TEM), but the results are inevitably influenced by the proximity of free surfaces. The prismatic loops are attracted to free surfaces by image forces. Depending on the type, size and depth of the loop in the foil, they can escape to the free surface, thus invalidating TEM observations and conclusions. In this article small prismatic hexagonal and circular dislocation loops in tungsten with the Burgers vectors 1/2 〈 1 1 1 〉 and 〈 1 0 0 〉 are studied by molecular statics simulations using three embedded atom method (EAM) potentials. The calculated image forces are compared to known elastic solutions. A particular attention is paid to the critical stress to move edge dislocations. The escape of the loop to the free surface is quantified by a combination of atomistic simulations and elastic calculations. For example, for the 1/2 〈 1 1 1 〉 loop with diameter 7.4 nm in a 55 nm thick foil we calculated that about one half of the loops will escape to the free surface. This implies that TEM observations detect only approx. 50% of the loops that were originally present in the foil.