García-Magariño, Iván; Lacuesta, Raquel; Lloret, Jaime
2018-03-27
Smart communication protocols are becoming a key mechanism for improving communication performance in networks such as wireless sensor networks. However, the literature lacks mechanisms for simulating smart communication protocols in precision agriculture for decreasing production costs. In this context, the current work presents an agent-based simulator of smart communication protocols for efficiently managing pesticides. The simulator considers the needs of electric power, crop health, percentage of alive bugs and pesticide consumption. The current approach is illustrated with three different communication protocols respectively called (a) broadcast, (b) neighbor and (c) low-cost neighbor. The low-cost neighbor protocol obtained a statistically-significant reduction in the need of electric power over the neighbor protocol, with a very large difference according to the common interpretations about the Cohen's d effect size. The presented simulator is called ABS-SmartComAgri and is freely distributed as open-source from a public research data repository. It ensures the reproducibility of experiments and allows other researchers to extend the current approach.
2018-01-01
Smart communication protocols are becoming a key mechanism for improving communication performance in networks such as wireless sensor networks. However, the literature lacks mechanisms for simulating smart communication protocols in precision agriculture for decreasing production costs. In this context, the current work presents an agent-based simulator of smart communication protocols for efficiently managing pesticides. The simulator considers the needs of electric power, crop health, percentage of alive bugs and pesticide consumption. The current approach is illustrated with three different communication protocols respectively called (a) broadcast, (b) neighbor and (c) low-cost neighbor. The low-cost neighbor protocol obtained a statistically-significant reduction in the need of electric power over the neighbor protocol, with a very large difference according to the common interpretations about the Cohen’s d effect size. The presented simulator is called ABS-SmartComAgri and is freely distributed as open-source from a public research data repository. It ensures the reproducibility of experiments and allows other researchers to extend the current approach. PMID:29584703
ShareSync: A Solution for Deterministic Data Sharing over Ethernet
NASA Technical Reports Server (NTRS)
Dunn, Daniel J., II; Koons, William A.; Kennedy, Richard D.; Davis, Philip A.
2007-01-01
As part of upgrading the Contact Dynamics Simulation Laboratory (CDSL) at the NASA Marshall Space Flight Center (MSFC), a simple, cost effective method was needed to communicate data among the networked simulation machines and I/O controllers used to run the facility. To fill this need and similar applicable situations, a generic protocol was developed, called ShareSync. ShareSync is a lightweight, real-time, publish-subscribe Ethernet protocol for simple and deterministic data sharing across diverse machines and operating systems. ShareSync provides a simple Application Programming Interface (API) for simulation programmers to incorporate into their code. The protocol is compatible with virtually all Ethernet-capable machines, is flexible enough to support a variety of applications, is fast enough to provide soft real-time determinism, and is a low-cost resource for distributed simulation development, deployment, and maintenance. The first design cycle iteration of ShareSync has been completed, and the protocol has undergone several testing procedures including endurance and benchmarking tests and approaches the 2001ts data synchronization design goal for the CDSL.
An Energy Balanced and Lifetime Extended Routing Protocol for Underwater Sensor Networks.
Wang, Hao; Wang, Shilian; Zhang, Eryang; Lu, Luxi
2018-05-17
Energy limitation is an adverse problem in designing routing protocols for underwater sensor networks (UWSNs). To prolong the network lifetime with limited battery power, an energy balanced and efficient routing protocol, called energy balanced and lifetime extended routing protocol (EBLE), is proposed in this paper. The proposed EBLE not only balances traffic loads according to the residual energy, but also optimizes data transmissions by selecting low-cost paths. Two phases are operated in the EBLE data transmission process: (1) candidate forwarding set selection phase and (2) data transmission phase. In candidate forwarding set selection phase, nodes update candidate forwarding nodes by broadcasting the position and residual energy level information. The cost value of available nodes is calculated and stored in each sensor node. Then in data transmission phase, high residual energy and relatively low-cost paths are selected based on the cost function and residual energy level information. We also introduce detailed analysis of optimal energy consumption in UWSNs. Numerical simulation results on a variety of node distributions and data load distributions prove that EBLE outperforms other routing protocols (BTM, BEAR and direct transmission) in terms of network lifetime and energy efficiency.
Michel, Miriam; Egender, Friedemann; Heßling, Vera; Dähnert, Ingo; Gebauer, Roman
2016-01-01
Background Postoperative junctional ectopic tachycardia (JET) occurs frequently after pediatric cardiac surgery. R-wave synchronized atrial (AVT) pacing is used to re-establish atrioventricular synchrony. AVT pacing is complex, with technical pitfalls. We sought to establish and to test a low-cost simulation model suitable for training and analysis in AVT pacing. Methods A simulation model was developed based on a JET simulator, a simulation doll, a cardiac monitor, and a pacemaker. A computer program simulated electrocardiograms. Ten experienced pediatric cardiologists tested the model. Their performance was analyzed using a testing protocol with 10 working steps. Results Four testers found the simulation model realistic; 6 found it very realistic. Nine claimed that the trial had improved their skills. All testers considered the model useful in teaching AVT pacing. The simulation test identified 5 working steps in which major mistakes in performance test may impede safe and effective AVT pacing and thus permitted specific training. The components of the model (exclusive monitor and pacemaker) cost less than $50. Assembly and training-session expenses were trivial. Conclusions A realistic, low-cost simulation model of AVT pacing is described. The model is suitable for teaching and analyzing AVT pacing technique. PMID:26943363
A General Self-Organized Tree-Based Energy-Balance Routing Protocol for Wireless Sensor Network
NASA Astrophysics Data System (ADS)
Han, Zhao; Wu, Jie; Zhang, Jie; Liu, Liefeng; Tian, Kaiyun
2014-04-01
Wireless sensor network (WSN) is a system composed of a large number of low-cost micro-sensors. This network is used to collect and send various kinds of messages to a base station (BS). WSN consists of low-cost nodes with limited battery power, and the battery replacement is not easy for WSN with thousands of physically embedded nodes, which means energy efficient routing protocol should be employed to offer a long-life work time. To achieve the aim, we need not only to minimize total energy consumption but also to balance WSN load. Researchers have proposed many protocols such as LEACH, HEED, PEGASIS, TBC and PEDAP. In this paper, we propose a General Self-Organized Tree-Based Energy-Balance routing protocol (GSTEB) which builds a routing tree using a process where, for each round, BS assigns a root node and broadcasts this selection to all sensor nodes. Subsequently, each node selects its parent by considering only itself and its neighbors' information, thus making GSTEB a dynamic protocol. Simulation results show that GSTEB has a better performance than other protocols in balancing energy consumption, thus prolonging the lifetime of WSN.
Villagómez, C; Suarez, F; Gómez, S; Dávila, A; Vega-Gonzalez, A; Gómez-González, J
2011-01-01
Providing appropriate cardio-pulmonary reanimation after cardio-pulmonary arrest is paramount for survival. An effective and low-cost approach to learn and practice the cardio-pulmonary reanimation is through a computerized life-size patient simulator. The present work describes the development of a patient simulator for the Centre of Education and Certification of Medical Aptitudes (CECAM) from the UNAM's Faculty of Medicine. This patient simulator has many new and innovative features, such real-time feedback to the medical student, which improves the whole teaching/learning experience.
A Proposal for Modeling Real Hardware, Weather and Marine Conditions for Underwater Sensor Networks
Climent, Salvador; Capella, Juan Vicente; Blanc, Sara; Perles, Angel; Serrano, Juan José
2013-01-01
Network simulators are useful for researching protocol performance, appraising new hardware capabilities and evaluating real application scenarios. However, these tasks can only be achieved when using accurate models and real parameters that enable the extraction of trustworthy results and conclusions. This paper presents an underwater wireless sensor network ecosystem for the ns-3 simulator. This ecosystem is composed of a new energy-harvesting model and a low-cost, low-power underwater wake-up modem model that, alongside existing models, enables the performance of accurate simulations by providing real weather and marine conditions from the location where the real application is to be deployed. PMID:23748171
Low Cost Simulator for Heart Surgery Training
Silva, Roberto Rocha e; Lourenção, Artur; Goncharov, Maxim; Jatene, Fabio B.
2016-01-01
Objective Introduce the low-cost and easy to purchase simulator without biological material so that any institution may promote extensive cardiovascular surgery training both in a hospital setting and at home without large budgets. Methods A transparent plastic box is placed in a wooden frame, which is held by the edges using elastic bands, with the bottom turned upwards, where an oval opening is made, "simulating" a thoracotomy. For basic exercises in the aorta, the model presented by our service in the 2015 Brazilian Congress of Cardiovascular Surgery: a silicone ice tray, where one can train to make aortic purse-string suture, aortotomy, aortorrhaphy and proximal and distal anastomoses. Simulators for the training of valve replacement and valvoplasty, atrial septal defect repair and aortic diseases were added. These simulators are based on sewage pipes obtained in construction material stores and the silicone trays and ethyl vinyl acetate tissue were obtained in utility stores, all of them at a very low cost. Results The models were manufactured using inert materials easily found in regular stores and do not present contamination risk. They may be used in any environment and maybe stored without any difficulties. This training enabled young surgeons to familiarize and train different surgical techniques, including procedures for aortic diseases. In a subjective assessment, these surgeons reported that the training period led to improved surgical techniques in the surgical field. Conclusion The model described in this protocol is effective and low-cost when compared to existing simulators, enabling a large array of cardiovascular surgery training. PMID:28076623
van der Roer, Nicole; van Tulder, Maurits; van Mechelen, Willem; de Vet, Henrica
2008-02-15
Economic evaluation from a societal perspective conducted alongside a randomized controlled trial with a follow-up of 52 weeks. To evaluate the cost effectiveness and cost utility of an intensive group training protocol compared with usual care physiotherapy in patients with nonspecific chronic low back pain. The intensive group training protocol combines exercise therapy, back school, and behavioral principles. Two studies found a significant reduction in absenteeism for a graded activity program in occupational health care. This program has not yet been evaluated in a primary care physiotherapy setting. Participating physical therapists in primary care recruited 114 patients with chronic nonspecific low back pain. Eligible patients were randomized to either the protocol group or the guideline group. Outcome measures included functional status (Roland Morris Disability Questionnaire), pain intensity (11-point numerical rating scale), general perceived effect and quality of life (EuroQol-5D). Cost data were measured with cost diaries and included direct and indirect costs related to low back pain. After 52 weeks, the direct health care costs were significantly higher for patients in the protocol group, largely due to the costs of the intervention. The mean difference in total costs amounted to [Euro sign] 233 (95% confidence interval: [Euro sign] -2.185; [Euro sign] 2.764). The cost-effectiveness planes indicated no significant differences in cost effectiveness between the 2 groups. The results of this economic evaluation showed no difference in total costs between the protocol group and the guideline group. The differences in effects were small and not statistically significant. At present, national implementation of the protocol is not recommended.
Using a Low Cost Flight Simulation Environment for Interdisciplinary Education
NASA Technical Reports Server (NTRS)
Khan, M. Javed; Rossi, Marcia; ALi, Syed F.
2004-01-01
A multi-disciplinary and inter-disciplinary education is increasingly being emphasized for engineering undergraduates. However, often the focus is on interaction between engineering disciplines. This paper discusses the experience at Tuskegee University in providing interdisciplinary research experiences for undergraduate students in both Aerospace Engineering and Psychology through the utilization of a low cost flight simulation environment. The environment, which is pc-based, runs a low-cost of-the-shelf software and is configured for multiple out-of-the-window views and a synthetic heads down display with joystick, rudder and throttle controls. While the environment is being utilized to investigate and evaluate various strategies for training novice pilots, students were involved to provide them with experience in conducting such interdisciplinary research. On the global inter-disciplinary level these experiences included developing experimental designs and research protocols, consideration of human participant ethical issues, and planning and executing the research studies. During the planning phase students were apprised of the limitations of the software in its basic form and the enhancements desired to investigate human factors issues. A number of enhancements to the flight environment were then undertaken, from creating Excel macros for determining the performance of the 'pilots', to interacting with the software to provide various audio/video cues based on the experimental protocol. These enhancements involved understanding the flight model and performance, stability & control issues. Throughout this process, discussions of data analysis included a focus from a human factors perspective as well as an engineering point of view.
van der Roer, Nicole; van Tulder, Maurits W; Barendse, Johanna M; van Mechelen, Willem; Franken, Willemien K; Ooms, Arjan C; de Vet, Henrica CW
2004-01-01
Background Low back pain is a common disorder in western industrialised countries and the type of treatments for low back pain vary considerably. Methods In a randomised controlled trial the cost-effectiveness and cost-utility of an intensive group training protocol versus physiotherapy guideline care for sub-acute and chronic low back pain patients is evaluated. Patients with back pain for longer than 6 weeks who are referred to physiotherapy care by their general practitioner or medical specialist are included in the study. The intensive group training protocol combines exercise therapy with principles of behavioural therapy ("graded activity") and back school. This training protocol is compared to physiotherapy care according to the recently published Low Back Pain Guidelines of the Royal Dutch College for Physiotherapy. Primary outcome measures are general improvement, pain intensity, functional status, work absenteeism and quality of life. The direct and indirect costs will be assessed using cost diaries. Patients will complete questionnaires at baseline and 6, 13, 26 and 52 weeks after randomisation. Discussion No trials are yet available that have evaluated the effect of an intensive group training protocol including behavioural principles and back school in a primary physiotherapy care setting and no data on cost-effectiveness and cost-utility are available. PMID:15560843
Kaitani, Toshiko; Nakagami, Gojiro; Iizaka, Shinji; Fukuda, Takashi; Oe, Makoto; Igarashi, Ataru; Mori, Taketoshi; Takemura, Yukie; Mizokami, Yuko; Sugama, Junko; Sanada, Hiromi
2015-01-01
The high prevalence of severe pressure ulcers (PUs) is an important issue that requires to be highlighted in Japan. In a previous study, we devised an advanced PU management protocol to enable early detection of and intervention for deep tissue injury and critical colonization. This protocol was effective for preventing more severe PUs. The present study aimed to compare the cost-effectiveness of the care provided using an advanced PU management protocol, from a medical provider's perspective, implemented by trained wound, ostomy, and continence nurses (WOCNs), with that of conventional care provided by a control group of WOCNs. A Markov model was constructed for a 1-year time horizon to determine the incremental cost-effectiveness ratio of advanced PU management compared with conventional care. The number of quality-adjusted life-years gained, and the cost in Japanese yen (¥) ($US1 = ¥120; 2015) was used as the outcome. Model inputs for clinical probabilities and related costs were based on our previous clinical trial results. Univariate sensitivity analyses were performed. Furthermore, a Bayesian multivariate probability sensitivity analysis was performed using Monte Carlo simulations with advanced PU management. Two different models were created for initial cohort distribution. For both models, the expected effectiveness for the intervention group using advanced PU management techniques was high, with a low expected cost value. The sensitivity analyses suggested that the results were robust. Intervention by WOCNs using advanced PU management techniques was more effective and cost-effective than conventional care. © 2015 by the Wound Healing Society.
NASA Astrophysics Data System (ADS)
Mack, Ian W.; Potts, Stephen; McMenemy, Karen R.; Ferguson, R. S.
2006-02-01
The laparoscopic technique for performing abdominal surgery requires a very high degree of skill in the medical practitioner. Much interest has been focused on using computer graphics to provide simulators for training surgeons. Unfortunately, these tend to be complex and have a very high cost, which limits availability and restricts the length of time over which individuals can practice their skills. With computer game technology able to provide the graphics required for a surgical simulator, the cost does not have to be high. However, graphics alone cannot serve as a training simulator. Human interface hardware, the equivalent of the force feedback joystick for a flight simulator game, is required to complete the system. This paper presents a design for a very low cost device to address this vital issue. The design encompasses: the mechanical construction, the electronic interfaces and the software protocols to mimic a laparoscopic surgical set-up. Thus the surgeon has the capability of practicing two-handed procedures with the possibility of force feedback. The force feedback and collision detection algorithms allow surgeons to practice realistic operating theatre procedures with a good degree of authenticity.
Multicast Delayed Authentication For Streaming Synchrophasor Data in the Smart Grid
Câmara, Sérgio; Anand, Dhananjay; Pillitteri, Victoria; Carmo, Luiz
2017-01-01
Multicast authentication of synchrophasor data is challenging due to the design requirements of Smart Grid monitoring systems such as low security overhead, tolerance of lossy networks, time-criticality and high data rates. In this work, we propose inf -TESLA, Infinite Timed Efficient Stream Loss-tolerant Authentication, a multicast delayed authentication protocol for communication links used to stream synchrophasor data for wide area control of electric power networks. Our approach is based on the authentication protocol TESLA but is augmented to accommodate high frequency transmissions of unbounded length. inf TESLA protocol utilizes the Dual Offset Key Chains mechanism to reduce authentication delay and computational cost associated with key chain commitment. We provide a description of the mechanism using two different modes for disclosing keys and demonstrate its security against a man-in-the-middle attack attempt. We compare our approach against the TESLA protocol in a 2-day simulation scenario, showing a reduction of 15.82% and 47.29% in computational cost, sender and receiver respectively, and a cumulative reduction in the communication overhead. PMID:28736582
Multicast Delayed Authentication For Streaming Synchrophasor Data in the Smart Grid.
Câmara, Sérgio; Anand, Dhananjay; Pillitteri, Victoria; Carmo, Luiz
2016-01-01
Multicast authentication of synchrophasor data is challenging due to the design requirements of Smart Grid monitoring systems such as low security overhead, tolerance of lossy networks, time-criticality and high data rates. In this work, we propose inf -TESLA, Infinite Timed Efficient Stream Loss-tolerant Authentication, a multicast delayed authentication protocol for communication links used to stream synchrophasor data for wide area control of electric power networks. Our approach is based on the authentication protocol TESLA but is augmented to accommodate high frequency transmissions of unbounded length. inf TESLA protocol utilizes the Dual Offset Key Chains mechanism to reduce authentication delay and computational cost associated with key chain commitment. We provide a description of the mechanism using two different modes for disclosing keys and demonstrate its security against a man-in-the-middle attack attempt. We compare our approach against the TESLA protocol in a 2-day simulation scenario, showing a reduction of 15.82% and 47.29% in computational cost, sender and receiver respectively, and a cumulative reduction in the communication overhead.
Secure anonymous mutual authentication for star two-tier wireless body area networks.
Ibrahim, Maged Hamada; Kumari, Saru; Das, Ashok Kumar; Wazid, Mohammad; Odelu, Vanga
2016-10-01
Mutual authentication is a very important service that must be established between sensor nodes in wireless body area network (WBAN) to ensure the originality and integrity of the patient's data sent by sensors distributed on different parts of the body. However, mutual authentication service is not enough. An adversary can benefit from monitoring the traffic and knowing which sensor is in transmission of patient's data. Observing the traffic (even without disclosing the context) and knowing its origin, it can reveal to the adversary information about the patient's medical conditions. Therefore, anonymity of the communicating sensors is an important service as well. Few works have been conducted in the area of mutual authentication among sensor nodes in WBAN. However, none of them has considered anonymity among body sensor nodes. Up to our knowledge, our protocol is the first attempt to consider this service in a two-tier WBAN. We propose a new secure protocol to realize anonymous mutual authentication and confidential transmission for star two-tier WBAN topology. The proposed protocol uses simple cryptographic primitives. We prove the security of the proposed protocol using the widely-accepted Burrows-Abadi-Needham (BAN) logic, and also through rigorous informal security analysis. In addition, to demonstrate the practicality of our protocol, we evaluate it using NS-2 simulator. BAN logic and informal security analysis prove that our proposed protocol achieves the necessary security requirements and goals of an authentication service. The simulation results show the impact on the various network parameters, such as end-to-end delay and throughput. The nodes in the network require to store few hundred bits. Nodes require to perform very few hash invocations, which are computationally very efficient. The communication cost of the proposed protocol is few hundred bits in one round of communication. Due to the low computation cost, the energy consumed by the nodes is also low. Our proposed protocol is a lightweight anonymous mutually authentication protocol to mutually authenticate the sensor nodes with the controller node (hub) in a star two-tier WBAN topology. Results show that our protocol proves efficiency over previously proposed protocols and at the same time, achieves the necessary security requirements for a secure anonymous mutual authentication scheme. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Low Resolution Picture Transmission (LRPT) Demonstration System
NASA Technical Reports Server (NTRS)
Fong, Wai; Yeh, Pen-Shu; Sank, Victor; Nyugen, Xuan; Xia, Wei; Duran, Steve; Day, John H. (Technical Monitor)
2002-01-01
Low-Resolution Picture Transmission (LRPT) is a proposed standard for direct broadcast transmission of satellite weather images. This standard is a joint effort by the European Organization for the Exploitation of Meteorological Satellites (EUMETSAT) and the National Oceanic Atmospheric Administration (NOAA). As a digital transmission scheme, its purpose is to replace the current analog Automatic Picture Transmission (APT) system for use in the Meteorological Operational (METOP) satellites. Goddard Space Flight Center has been tasked to build an LRPT Demonstration System (LDS). It's main objective is to develop or demonstrate the feasibility of a low-cost receiver utilizing a Personal Computer (PC) as the primary processing component and determine the performance of the protocol in the simulated Radio Frequency (RF) environment. The approach would consist of two phases. In the phase 1, a Commercial-off-the-Shelf (COTS) Modulator-Demodulator (MODEM) board that would perform RF demodulation would be purchased allowing the Central Processing Unit (CPU) to perform the Consultative Committee for Space Data Systems (CCSDS) protocol processing. Also since the weather images are compressed the PC would perform the decompression. Phase 1 was successfully demonstrated on December 1997. Phase 2 consists of developing a high-fidelity receiver, transmitter and environment simulator. Its goal is to find out how the METOP Specification performs in a simulated noise environment in a cost-effective receiver. The approach would be to produce a receiver using as much software as possible to perform front-end processing to take advantage of the latest high-speed PCs. Thus the COTS MODEM used in Phase 1 is performing RF demodulation along with data acquisition providing data to the receiving software. Also, environment simulator is produced using the noise patterns generated by Institute for Telecommunications Sciences (ITS) from their noise environment study.
Chen, Yibo; Chanet, Jean-Pierre; Hou, Kun-Mean; Shi, Hongling; de Sousa, Gil
2015-08-10
In recent years, IoT (Internet of Things) technologies have seen great advances, particularly, the IPv6 Routing Protocol for Low-power and Lossy Networks (RPL), which provides a powerful and flexible routing framework that can be applied in a variety of application scenarios. In this context, as an important role of IoT, Wireless Sensor Networks (WSNs) can utilize RPL to design efficient routing protocols for a specific application to increase the ubiquity of networks with resource-constrained WSN nodes that are low-cost and easy to deploy. In this article, our work starts with the description of Agricultural Low-power and Lossy Networks (A-LLNs) complying with the LLN framework, and to clarify the requirements of this application-oriented routing solution. After a brief review of existing optimization techniques for RPL, our contribution is dedicated to a Scalable Context-Aware Objective Function (SCAOF) that can adapt RPL to the environmental monitoring of A-LLNs, through combining energy-aware, reliability-aware, robustness-aware and resource-aware contexts according to the composite routing metrics approach. The correct behavior of this enhanced RPL version (RPAL) was verified by performance evaluations on both simulation and field tests. The obtained experimental results confirm that SCAOF can deliver the desired advantages on network lifetime extension, and high reliability and efficiency in different simulation scenarios and hardware testbeds.
Chen, Yibo; Chanet, Jean-Pierre; Hou, Kun-Mean; Shi, Hongling; de Sousa, Gil
2015-01-01
In recent years, IoT (Internet of Things) technologies have seen great advances, particularly, the IPv6 Routing Protocol for Low-power and Lossy Networks (RPL), which provides a powerful and flexible routing framework that can be applied in a variety of application scenarios. In this context, as an important role of IoT, Wireless Sensor Networks (WSNs) can utilize RPL to design efficient routing protocols for a specific application to increase the ubiquity of networks with resource-constrained WSN nodes that are low-cost and easy to deploy. In this article, our work starts with the description of Agricultural Low-power and Lossy Networks (A-LLNs) complying with the LLN framework, and to clarify the requirements of this application-oriented routing solution. After a brief review of existing optimization techniques for RPL, our contribution is dedicated to a Scalable Context-Aware Objective Function (SCAOF) that can adapt RPL to the environmental monitoring of A-LLNs, through combining energy-aware, reliability-aware, robustness-aware and resource-aware contexts according to the composite routing metrics approach. The correct behavior of this enhanced RPL version (RPAL) was verified by performance evaluations on both simulation and field tests. The obtained experimental results confirm that SCAOF can deliver the desired advantages on network lifetime extension, and high reliability and efficiency in different simulation scenarios and hardware testbeds. PMID:26266411
Protocols for efficient simulations of long-time protein dynamics using coarse-grained CABS model.
Jamroz, Michal; Kolinski, Andrzej; Kmiecik, Sebastian
2014-01-01
Coarse-grained (CG) modeling is a well-acknowledged simulation approach for getting insight into long-time scale protein folding events at reasonable computational cost. Depending on the design of a CG model, the simulation protocols vary from highly case-specific-requiring user-defined assumptions about the folding scenario-to more sophisticated blind prediction methods for which only a protein sequence is required. Here we describe the framework protocol for the simulations of long-term dynamics of globular proteins, with the use of the CABS CG protein model and sequence data. The simulations can start from a random or a selected (e.g., native) structure. The described protocol has been validated using experimental data for protein folding model systems-the prediction results agreed well with the experimental results.
Design and Field Test of a WSN Platform Prototype for Long-Term Environmental Monitoring
Lazarescu, Mihai T.
2015-01-01
Long-term wildfire monitoring using distributed in situ temperature sensors is an accurate, yet demanding environmental monitoring application, which requires long-life, low-maintenance, low-cost sensors and a simple, fast, error-proof deployment procedure. We present in this paper the most important design considerations and optimizations of all elements of a low-cost WSN platform prototype for long-term, low-maintenance pervasive wildfire monitoring, its preparation for a nearly three-month field test, the analysis of the causes of failure during the test and the lessons learned for platform improvement. The main components of the total cost of the platform (nodes, deployment and maintenance) are carefully analyzed and optimized for this application. The gateways are designed to operate with resources that are generally used for sensor nodes, while the requirements and cost of the sensor nodes are significantly lower. We define and test in simulation and in the field experiment a simple, but effective communication protocol for this application. It helps to lower the cost of the nodes and field deployment procedure, while extending the theoretical lifetime of the sensor nodes to over 16 years on a single 1 Ah lithium battery. PMID:25912349
Simulation of Lunar Surface Communications Network Exploration Scenarios
NASA Technical Reports Server (NTRS)
Linsky, Thomas W.; Bhasin, Kul B.; White, Alex; Palangala, Srihari
2006-01-01
Simulations and modeling of surface-based communications networks provides a rapid and cost effective means of requirement analysis, protocol assessments, and tradeoff studies. Robust testing in especially important for exploration systems, where the cost of deployment is high and systems cannot be easily replaced or repaired. However, simulation of the envisioned exploration networks cannot be achieved using commercial off the shelf network simulation software. Models for the nonstandard, non-COTS protocols used aboard space systems are not readily available. This paper will address the simulation of realistic scenarios representative of the activities which will take place on the surface of the Moon, including selection of candidate network architectures, and the development of an integrated simulation tool using OPNET modeler capable of faithfully modeling those communications scenarios in the variable delay, dynamic surface environments. Scenarios for exploration missions, OPNET development, limitations, and simulations results will be provided and discussed.
Wright, Melanie C; Taekman, Jeffrey M; Barber, Linda; Hobbs, Gene; Newman, Mark F; Stafford-Smith, Mark
2005-12-01
Errors in clinical research can be costly, in terms of patient safety, data integrity, and data collection. Data inaccuracy in early subjects of a clinical study may be associated with problems in the design of the protocol, procedures, and data collection tools. High-fidelity patient simulation centers provide an ideal environment to apply human-centered design to clinical trial development. A draft of a complex clinical protocol was designed, evaluated and modified using a high-fidelity human patient simulator in the Duke University Human Simulation and Patient Safety Center. The process included walk-throughs, detailed modifications of the protocol and development of procedural aids. Training of monitors and coordinators provided an opportunity for observation of performance that was used to identify further improvements to the protocol. Evaluative steps were used to design the research protocol and procedures. Iterative modifications were made to the protocol and data collection tools. The success in use of human simulation in the preparation of a complex clinical drug trial suggests the benefits of human patient simulation extend beyond training and medical equipment evaluation. Human patient simulation can provide a context for informal expert evaluation of clinical protocol design and for formal "rehearsal" to evaluate the efficacy of procedures and support tools.
A design of wireless sensor networks for a power quality monitoring system.
Lim, Yujin; Kim, Hak-Man; Kang, Sanggil
2010-01-01
Power grids deal with the business of generation, transmission, and distribution of electric power. Recently, interest in power quality in electrical distribution systems has increased rapidly. In Korea, the communication network to deliver voltage, current, and temperature measurements gathered from pole transformers to remote monitoring centers employs cellular mobile technology. Due to high cost of the cellular mobile technology, power quality monitoring measurements are limited and data gathering intervals are large. This causes difficulties in providing the power quality monitoring service. To alleviate the problems, in this paper we present a communication infrastructure to provide low cost, reliable data delivery. The communication infrastructure consists of wired connections between substations and monitoring centers, and wireless connections between pole transformers and substations. For the wireless connection, we employ a wireless sensor network and design its corresponding data forwarding protocol to improve the quality of data delivery. For the design, we adopt a tree-based data forwarding protocol in order to customize the distribution pattern of the power quality information. We verify the performance of the proposed data forwarding protocol quantitatively using the NS-2 network simulator.
Graphical user interface for wireless sensor networks simulator
NASA Astrophysics Data System (ADS)
Paczesny, Tomasz; Paczesny, Daniel; Weremczuk, Jerzy
2008-01-01
Wireless Sensor Networks (WSN) are currently very popular area of development. It can be suited in many applications form military through environment monitoring, healthcare, home automation and others. Those networks, when working in dynamic, ad-hoc model, need effective protocols which must differ from common computer networks algorithms. Research on those protocols would be difficult without simulation tool, because real applications often use many nodes and tests on such a big networks take much effort and costs. The paper presents Graphical User Interface (GUI) for simulator which is dedicated for WSN studies, especially in routing and data link protocols evaluation.
Prigoff, Jake G; Swain, Gary W; Divino, Celia M
2016-05-01
Predicting the presence of a persistent common bile duct (CBD) stone is a difficult and expensive task. The aim of this study is to determine if a previously described protocol-based scoring system is a cost-effective strategy. The protocol includes all patients with gallstone pancreatitis and stratifies them based on laboratory values and imaging to high, medium, and low likelihood of persistent stones. The patient's stratification then dictates the next course of management. A decision analytic model was developed to compare the costs for patients who followed the protocol versus those that did not. Clinical data model inputs were obtained from a prospective study conducted at The Mount Sinai Medical Center to validate the protocol from Oct 2009 to May 2013. The study included all patients presenting with gallstone pancreatitis regardless of disease severity. Seventy-three patients followed the proposed protocol and 32 did not. The protocol group cost an average of $14,962/patient and the non-protocol group cost $17,138/patient for procedural costs. Mean length of stay for protocol and non-protocol patients was 5.6 and 7.7 days, respectively. The proposed protocol is a cost-effective way to determine the course for patients with gallstone pancreatitis, reducing total procedural costs over 12 %.
IMHRP: Improved Multi-Hop Routing Protocol for Wireless Sensor Networks
NASA Astrophysics Data System (ADS)
Huang, Jianhua; Ruan, Danwei; Hong, Yadong; Zhao, Ziming; Zheng, Hong
2017-10-01
Wireless sensor network (WSN) is a self-organizing system formed by a large number of low-cost sensor nodes through wireless communication. Sensor nodes collect environmental information and transmit it to the base station (BS). Sensor nodes usually have very limited battery energy. The batteries cannot be charged or replaced. Therefore, it is necessary to design an energy efficient routing protocol to maximize the network lifetime. This paper presents an improved multi-hop routing protocol (IMHRP) for homogeneous networks. In the IMHRP protocol, based on the distances to the BS, the CH nodes are divided into internal CH nodes and external CH nodes. The set-up phase of the protocol is based on the LEACH protocol and the minimum distance between CH nodes are limited to a special constant distance, so a more uniform distribution of CH nodes is achieved. In the steady-state phase, the routes of different CH nodes are created on the basis of the distances between the CH nodes. The energy efficiency of communication can be maximized. The simulation results show that the proposed algorithm can more effectively reduce the energy consumption of each round and prolong the network lifetime compared with LEACH protocol and MHT protocol.
Designing of Roaming Protocol for Bluetooth Equipped Multi Agent Systems
NASA Astrophysics Data System (ADS)
Subhan, Fazli; Hasbullah, Halabi B.
Bluetooth is an established standard for low cost, low power, wireless personal area network. Currently, Bluetooth does not support any roaming protocol in which handoff occurs dynamically when a Bluetooth device is moving out of the piconet. If a device is losing its connection to the master device, no provision is made to transfer it to another master. Handoff is not possible in a piconet, as in order to stay within the network, a slave would have to keep the same master. So, by definition intra-handoff is not possible within a piconet. This research mainly focuses on Bluetooth technology and designing a roaming protocol for Bluetooth equipped multi agent systems. A mathematical model is derived for an agent. The idea behind the mathematical model is to know when to initiate the roaming process for an agent. A desired trajectory for the agent is calculated using its x and y coordinates system, and is simulated in SIMULINK. Various roaming techniques are also studied and discussed. The advantage of designing a roaming protocol is to ensure the Bluetooth enabled roaming devices can freely move inside the network coverage without losing its connection or break of service in case of changing the base stations.
GTRF: a game theory approach for regulating node behavior in real-time wireless sensor networks.
Lin, Chi; Wu, Guowei; Pirozmand, Poria
2015-06-04
The selfish behaviors of nodes (or selfish nodes) cause packet loss, network congestion or even void regions in real-time wireless sensor networks, which greatly decrease the network performance. Previous methods have focused on detecting selfish nodes or avoiding selfish behavior, but little attention has been paid to regulating selfish behavior. In this paper, a Game Theory-based Real-time & Fault-tolerant (GTRF) routing protocol is proposed. GTRF is composed of two stages. In the first stage, a game theory model named VA is developed to regulate nodes' behaviors and meanwhile balance energy cost. In the second stage, a jumping transmission method is adopted, which ensures that real-time packets can be successfully delivered to the sink before a specific deadline. We prove that GTRF theoretically meets real-time requirements with low energy cost. Finally, extensive simulations are conducted to demonstrate the performance of our scheme. Simulation results show that GTRF not only balances the energy cost of the network, but also prolongs network lifetime.
Scalable parallel communications
NASA Technical Reports Server (NTRS)
Maly, K.; Khanna, S.; Overstreet, C. M.; Mukkamala, R.; Zubair, M.; Sekhar, Y. S.; Foudriat, E. C.
1992-01-01
Coarse-grain parallelism in networking (that is, the use of multiple protocol processors running replicated software sending over several physical channels) can be used to provide gigabit communications for a single application. Since parallel network performance is highly dependent on real issues such as hardware properties (e.g., memory speeds and cache hit rates), operating system overhead (e.g., interrupt handling), and protocol performance (e.g., effect of timeouts), we have performed detailed simulations studies of both a bus-based multiprocessor workstation node (based on the Sun Galaxy MP multiprocessor) and a distributed-memory parallel computer node (based on the Touchstone DELTA) to evaluate the behavior of coarse-grain parallelism. Our results indicate: (1) coarse-grain parallelism can deliver multiple 100 Mbps with currently available hardware platforms and existing networking protocols (such as Transmission Control Protocol/Internet Protocol (TCP/IP) and parallel Fiber Distributed Data Interface (FDDI) rings); (2) scale-up is near linear in n, the number of protocol processors, and channels (for small n and up to a few hundred Mbps); and (3) since these results are based on existing hardware without specialized devices (except perhaps for some simple modifications of the FDDI boards), this is a low cost solution to providing multiple 100 Mbps on current machines. In addition, from both the performance analysis and the properties of these architectures, we conclude: (1) multiple processors providing identical services and the use of space division multiplexing for the physical channels can provide better reliability than monolithic approaches (it also provides graceful degradation and low-cost load balancing); (2) coarse-grain parallelism supports running several transport protocols in parallel to provide different types of service (for example, one TCP handles small messages for many users, other TCP's running in parallel provide high bandwidth service to a single application); and (3) coarse grain parallelism will be able to incorporate many future improvements from related work (e.g., reduced data movement, fast TCP, fine-grain parallelism) also with near linear speed-ups.
Duncan, James R; Kline, Benjamin; Glaiberman, Craig B
2007-04-01
To create and test methods of extracting efficiency data from recordings of simulated renal stent procedures. Task analysis was performed and used to design a standardized testing protocol. Five experienced angiographers then performed 16 renal stent simulations using the Simbionix AngioMentor angiographic simulator. Audio and video recordings of these simulations were captured from multiple vantage points. The recordings were synchronized and compiled. A series of efficiency metrics (procedure time, contrast volume, and tool use) were then extracted from the recordings. The intraobserver and interobserver variability of these individual metrics was also assessed. The metrics were converted to costs and aggregated to determine the fixed and variable costs of a procedure segment or the entire procedure. Task analysis and pilot testing led to a standardized testing protocol suitable for performance assessment. Task analysis also identified seven checkpoints that divided the renal stent simulations into six segments. Efficiency metrics for these different segments were extracted from the recordings and showed excellent intra- and interobserver correlations. Analysis of the individual and aggregated efficiency metrics demonstrated large differences between segments as well as between different angiographers. These differences persisted when efficiency was expressed as either total or variable costs. Task analysis facilitated both protocol development and data analysis. Efficiency metrics were readily extracted from recordings of simulated procedures. Aggregating the metrics and dividing the procedure into segments revealed potential insights that could be easily overlooked because the simulator currently does not attempt to aggregate the metrics and only provides data derived from the entire procedure. The data indicate that analysis of simulated angiographic procedures will be a powerful method of assessing performance in interventional radiology.
Efficiency in nonequilibrium molecular dynamics Monte Carlo simulations
Radak, Brian K.; Roux, Benoît
2016-10-07
Hybrid algorithms combining nonequilibrium molecular dynamics and Monte Carlo (neMD/MC) offer a powerful avenue for improving the sampling efficiency of computer simulations of complex systems. These neMD/MC algorithms are also increasingly finding use in applications where conventional approaches are impractical, such as constant-pH simulations with explicit solvent. However, selecting an optimal nonequilibrium protocol for maximum efficiency often represents a non-trivial challenge. This work evaluates the efficiency of a broad class of neMD/MC algorithms and protocols within the theoretical framework of linear response theory. The approximations are validated against constant pH-MD simulations and shown to provide accurate predictions of neMD/MC performance.more » An assessment of a large set of protocols confirms (both theoretically and empirically) that a linear work protocol gives the best neMD/MC performance. Lastly, a well-defined criterion for optimizing the time parameters of the protocol is proposed and demonstrated with an adaptive algorithm that improves the performance on-the-fly with minimal cost.« less
Cost-effective and low-technology options for simulation and training in neonatology.
Bruno, Christie J; Glass, Kristen M
2016-11-01
The purpose of this review is to explore low-cost options for simulation and training in neonatology. Numerous cost-effective options exist for simulation and training in neonatology. Lower cost options are available for teaching clinical skills and procedural training in neonatal intubation, chest tube insertion, and pericardiocentesis, among others. Cost-effective, low-cost options for simulation-based education can be developed and shared in order to optimize the neonatal simulation training experience. Copyright © 2016 Elsevier Inc. All rights reserved.
Dewan, Vinay; Lambert, Dennis; Edler, Joshua; Kymes, Steven; Apte, Rajendra S
2012-08-01
Perform a cost-effectiveness analysis of the treatment of diabetic macular edema (DME) with ranibizumab plus prompt or deferred laser versus triamcinolone plus prompt laser. Data for the analysis were drawn from reports of the Diabetic Retinopathy Clinical Research Network (DRCRnet) Protocol I. Computer simulation based on Protocol I data. Analyses were conducted from the payor perspective. Simulated participants assigned characteristics reflecting those seen in Protocol I. Markov models were constructed to replicate Protocol I's 104-week outcomes using a microsimulation approach to estimation. Baseline characteristics, visual acuity (VA), treatments, and complications were based on Protocol I data. Costs were identified by literature search. One-way sensitivity analysis was performed, and the results were validated against Protocol I data. Direct cost of care for 2 years, change in VA from baseline, and incremental cost-effectiveness ratio (ICER) measured as cost per additional letter gained from baseline (Early Treatment of Diabetic Retinopathy Study). For sham plus laser (S+L), ranibizumab plus prompt laser (R+pL), ranibizumab plus deferred laser (R+dL), and triamcinolone plus laser (T+L), effectiveness through 104 weeks was predicted to be 3.46, 7.07, 8.63, and 2.40 letters correct, respectively. The ICER values in terms of dollars per VA letter were $393 (S+L vs. T+L), $5943 (R+pL vs. S+L), and $20 (R+dL vs. R+pL). For pseudophakics, the ICER value for comparison triamcinolone with laser versus ranibizumab with deferred laser was $14 690 per letter gained. No clinically relevant changes in model variables altered outcomes. Internal validation demonstrated good similarity to Protocol I treatment patterns. In treatment of phakic patients with DME, ranibizumab with deferred laser provided an additional 6 letters correct compared with triamcinolone with laser at an additional cost of $19 216 over 2 years. That would indicate that if the gain in VA seen at 2 years is maintained in subsequent years, then the treatment of phakic patients with DME using ranibizumab may meet accepted standards of cost-effectiveness. For pseudophakic patients, first-line treatment with triamcinolone seems to be the most cost-effective option. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Pant, Manu
2016-03-01
In tissue culture, high production cost of the products restricts their reach. Though tissue culture is a major strength in floriculture it is marred by pricing issues. Hence, we developed a complete regeneration low cost micropropagation protocol for an economically important floriculture crop, carnation (Dianthus caryophyllus L.). Successful regeneration of carnation from nodal explants on cost-efficient medium indicates that psyllium husk, sugar and RO water can effectively replace the conventional medium comprising agar, sucrose and distilled water. The protocol can contribute to increased carnation production at comparatively reduced cost, and there by encourage wide scale adoption by the common growers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duan, Sisi; Li, Yun; Levitt, Karl N.
Consensus is a fundamental approach to implementing fault-tolerant services through replication where there exists a tradeoff between the cost and the resilience. For instance, Crash Fault Tolerant (CFT) protocols have a low cost but can only handle crash failures while Byzantine Fault Tolerant (BFT) protocols handle arbitrary failures but have a higher cost. Hybrid protocols enjoy the benefits of both high performance without failures and high resiliency under failures by switching among different subprotocols. However, it is challenging to determine which subprotocols should be used. We propose a moving target approach to switch among protocols according to the existing systemmore » and network vulnerability. At the core of our approach is a formalized cost model that evaluates the vulnerability and performance of consensus protocols based on real-time Intrusion Detection System (IDS) signals. Based on the evaluation results, we demonstrate that a safe, cheap, and unpredictable protocol is always used and a high IDS error rate can be tolerated.« less
NASA Astrophysics Data System (ADS)
Piattoni, Jacopo; Candini, Gian Paolo; Pezzi, Giulio; Santoni, Fabio; Piergentili, Fabrizio
2012-12-01
This paper describes the design and the manufacturing of a Cubesat platform based on a plastic structure. The Cubesat structure has been realized in plastic material (ABS) using a "rapid prototyping" technique. The "rapid prototyping" technique has several advantages including fast implementation, accuracy in manufacturing small parts and low cost. Moreover, concerning the construction of a small satellite, this technique is very useful thanks to the accuracy achievable in details, which are sometimes difficult and expensive to realize with the use of tools machine. The structure must be able to withstand the launch loads. For this reason, several simulations using an FEM simulation and an intensive vibration test campaign have been performed in the system development and test phase. To demonstrate that this structure is suitable for hosting a complete satellite system, offering innovative integrated solutions, other subsystems have been developed and assembled. Despite its small size, this single unit (1U) Cubesat has a system for active attitude control, a redundant telecommunication system, a payload camera and a photovoltaic system based on high efficiency solar cells. The developed communication subsystem has small dimensions, low power consumption and low cost. An example of the innovations introduced is the antenna system, which has been manufactured inside the ABS structure. The communication protocol which has been implemented, the AX.25 protocol, is mainly used by radio amateurs. The communication system has the capability to transmit both telemetry and data from the payload, in this case a microcamera. The attitude control subsystem is based on an active magnetic system with magnetorquers for detumbling and momentum dumping and three reaction wheels for fine control. It has a total dimension of about 50×50×50 mm. A microcontroller implements the detumbling control law autonomously taking data from integrated magnetometers and executes pointing maneuvers on the basis of commands received in real time from ground. The subsystems developed for this Cubesat have also been designed to be scaled up for larger satellites such as 2U or 3U Cubesats. The additional volume can be used for more complex payloads. Thus the satellite can be used as a low cost platform for companies, institutions or universities to test components in space.
A Kalman Filter Implementation for Precision Improvement in Low-Cost GPS Positioning of Tractors
Gomez-Gil, Jaime; Ruiz-Gonzalez, Ruben; Alonso-Garcia, Sergio; Gomez-Gil, Francisco Javier
2013-01-01
Low-cost GPS receivers provide geodetic positioning information using the NMEA protocol, usually with eight digits for latitude and nine digits for longitude. When these geodetic coordinates are converted into Cartesian coordinates, the positions fit in a quantization grid of some decimeters in size, the dimensions of which vary depending on the point of the terrestrial surface. The aim of this study is to reduce the quantization errors of some low-cost GPS receivers by using a Kalman filter. Kinematic tractor model equations were employed to particularize the filter, which was tuned by applying Monte Carlo techniques to eighteen straight trajectories, to select the covariance matrices that produced the lowest Root Mean Square Error in these trajectories. Filter performance was tested by using straight tractor paths, which were either simulated or real trajectories acquired by a GPS receiver. The results show that the filter can reduce the quantization error in distance by around 43%. Moreover, it reduces the standard deviation of the heading by 75%. Data suggest that the proposed filter can satisfactorily preprocess the low-cost GPS receiver data when used in an assistance guidance GPS system for tractors. It could also be useful to smooth tractor GPS trajectories that are sharpened when the tractor moves over rough terrain. PMID:24217355
Low Resolution Picture Transmission (LRPT) Demonstration System. Phase II; 1.0
NASA Technical Reports Server (NTRS)
Fong, Wai; Yeh, Pen-Shu; Duran, Steve; Sank, Victor; Nyugen, Xuan; Xia, Wei; Day, John H. (Technical Monitor)
2002-01-01
Low-Resolution Picture Transmission (LRPT) is a proposed standard for direct broadcast transmission of satellite weather images. This standard is a joint effort by the European Organization for the Exploitation of Meteorological Satellites (EUMETSAT) and NOAA. As a digital transmission scheme, its purpose is to replace the current analog Automatic Picture Transmission (APT) system for use in the Meteorological Operational (METOP) satellites. GSFC has been tasked to build an LRPT Demonstration System (LDS). Its main objective is to develop or demonstrate the feasibility of a low-cost receiver utilizing a PC as the primary processing component and determine the performance of the protocol in the simulated Radio Frequency (RF) environment. The approach would consist of two phases.
EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards
EPA's air monitoring regulations require the use of Protocol Gases to set air pollution monitors. This protocol balances the government's need for accuracy with the producers' need for flexibility, low cost, and minimum external oversight.
2013-01-01
Background Dual sensory loss (DSL) has a negative impact on health and wellbeing and its prevalence is expected to increase due to demographic aging. However, specialized care or rehabilitation programs for DSL are scarce. Until now, low vision rehabilitation does not sufficiently target concurrent impairments in vision and hearing. This study aims to 1) develop a DSL protocol (for occupational therapists working in low vision rehabilitation) which focuses on optimal use of the senses and teaches DSL patients and their communication partners to use effective communication strategies, and 2) describe the multicenter parallel randomized controlled trial (RCT) designed to test the effectiveness and cost-effectiveness of the DSL protocol. Methods/design To develop a DSL protocol, literature was reviewed and content was discussed with professionals in eye/ear care (interviews/focus groups) and DSL patients (interviews). A pilot study was conducted to test and confirm the DSL protocol. In addition, a two-armed international multi-center RCT will evaluate the effectiveness and cost-effectiveness of the DSL protocol compared to waiting list controls, in 124 patients in low vision rehabilitation centers in the Netherlands and Belgium. Discussion This study provides a treatment protocol for rehabilitation of DSL within low vision rehabilitation, which aims to be a valuable addition to the general low vision rehabilitation care. Trial registration Netherlands Trial Register (NTR) identifier: NTR2843 PMID:23941667
MACHETE: Environment for Space Networking Evaluation
NASA Technical Reports Server (NTRS)
Jennings, Esther H.; Segui, John S.; Woo, Simon
2010-01-01
Space Exploration missions requires the design and implementation of space networking that differs from terrestrial networks. In a space networking architecture, interplanetary communication protocols need to be designed, validated and evaluated carefully to support different mission requirements. As actual systems are expensive to build, it is essential to have a low cost method to validate and verify mission/system designs and operations. This can be accomplished through simulation. Simulation can aid design decisions where alternative solutions are being considered, support trade-studies and enable fast study of what-if scenarios. It can be used to identify risks, verify system performance against requirements, and as an initial test environment as one moves towards emulation and actual hardware implementation of the systems. We describe the development of Multi-mission Advanced Communications Hybrid Environment for Test and Evaluation (MACHETE) and its use cases in supporting architecture trade studies, protocol performance and its role in hybrid simulation/emulation. The MACHETE environment contains various tools and interfaces such that users may select the set of tools tailored for the specific simulation end goal. The use cases illustrate tool combinations for simulating space networking in different mission scenarios. This simulation environment is useful in supporting space networking design for planned and future missions as well as evaluating performance of existing networks where non-determinism exist in data traffic and/or link conditions.
Amin, Ruhul; Islam, S K Hafizul; Biswas, G P; Khan, Muhammad Khurram; Obaidat, Mohammad S
2015-11-01
In order to access remote medical server, generally the patients utilize smart card to login to the server. It has been observed that most of the user (patient) authentication protocols suffer from smart card stolen attack that means the attacker can mount several common attacks after extracting smart card information. Recently, Lu et al.'s proposes a session key agreement protocol between the patient and remote medical server and claims that the same protocol is secure against relevant security attacks. However, this paper presents several security attacks on Lu et al.'s protocol such as identity trace attack, new smart card issue attack, patient impersonation attack and medical server impersonation attack. In order to fix the mentioned security pitfalls including smart card stolen attack, this paper proposes an efficient remote mutual authentication protocol using smart card. We have then simulated the proposed protocol using widely-accepted AVISPA simulation tool whose results make certain that the same protocol is secure against active and passive attacks including replay and man-in-the-middle attacks. Moreover, the rigorous security analysis proves that the proposed protocol provides strong security protection on the relevant security attacks including smart card stolen attack. We compare the proposed scheme with several related schemes in terms of computation cost and communication cost as well as security functionalities. It has been observed that the proposed scheme is comparatively better than related existing schemes.
A novel Smart Routing Protocol for remote health monitoring in Medical Wireless Networks.
Sundararajan, T V P; Sumithra, M G; Maheswar, R
2014-01-01
In a Medical Wireless Network (MWN), sensors constantly monitor patient's physiological condition and movement. Inter-MWN communications are set up between the Patient Server and one or more Centralized Coordinators. However, MWNs require protocols with little energy consumption and the self-organizing attribute perceived in ad-hoc networks. The proposed Smart Routing Protocol (SRP) selects only the nodes with a higher residual energy and lower traffic density for routing. This approach enhances cooperation among the nodes of a Mobile Ad Hoc Network. Consequently, SRP produces better results than the existing protocols, namely Conditional Min-Max Battery Cost Routing, Min-Max Battery Cost Routing and AdHoc On-demand Distance Vector in terms of network parameters. The performance of the erstwhile schemes for routing protocols is evaluated using the network simulator Qualnet v 4.5.
Aghdasi, Hadi S; Abbaspour, Maghsoud; Moghadam, Mohsen Ebrahimi; Samei, Yasaman
2008-08-04
Technological progress in the fields of Micro Electro-Mechanical Systems (MEMS) and wireless communications and also the availability of CMOS cameras, microphones and small-scale array sensors, which may ubiquitously capture multimedia content from the field, have fostered the development of low-cost limited resources Wireless Video-based Sensor Networks (WVSN). With regards to the constraints of videobased sensor nodes and wireless sensor networks, a supporting video stream is not easy to implement with the present sensor network protocols. In this paper, a thorough architecture is presented for video transmission over WVSN called Energy-efficient and high-Quality Video transmission Architecture (EQV-Architecture). This architecture influences three layers of communication protocol stack and considers wireless video sensor nodes constraints like limited process and energy resources while video quality is preserved in the receiver side. Application, transport, and network layers are the layers in which the compression protocol, transport protocol, and routing protocol are proposed respectively, also a dropping scheme is presented in network layer. Simulation results over various environments with dissimilar conditions revealed the effectiveness of the architecture in improving the lifetime of the network as well as preserving the video quality.
Portable ultrasonography in mass casualty incidents: The CAVEAT examination.
Stawicki, Stanislaw Peter; Howard, James M; Pryor, John P; Bahner, David P; Whitmill, Melissa L; Dean, Anthony J
2010-11-18
Ultrasonography used by practicing clinicians has been shown to be of utility in the evaluation of time-sensitive and critical illnesses in a range of environments, including pre-hospital triage, emergency department, and critical care settings. The increasing availability of light-weight, robust, user-friendly, and low-cost portable ultrasound equipment is particularly suited for use in the physically and temporally challenging environment of a multiple casualty incident (MCI). Currently established ultrasound applications used to identify potentially lethal thoracic or abdominal conditions offer a base upon which rapid, focused protocols using hand-carried emergency ultrasonography could be developed. Following a detailed review of the current use of portable ultrasonography in military and civilian MCI settings, we propose a protocol for sonographic evaluation of the chest, abdomen, vena cava, and extremities for acute triage. The protocol is two-tiered, based on the urgency and technical difficulty of the sonographic examination. In addition to utilization of well-established bedside abdominal and thoracic sonography applications, this protocol incorporates extremity assessment for long-bone fractures. Studies of the proposed protocol will need to be conducted to determine its utility in simulated and actual MCI settings.
Coleman, Margaret S; Marienau, Karen J; Marano, Nina; Marks, Suzanne M; Cetron, Martin S
2014-01-01
In 2011, the Centers for Disease Control and Prevention modified its 2008 protocol for flight-related tuberculosis contact investigation initiation. The 2011 Modified protocol was implemented and replaced the 2008 CDC protocol based on comparative epidemiologic and economic analyses; this publication reports the economic analysis results. A return on investment model compared relative changes in tuberculosis disease treatment costs resulting from expenditures on tuberculosis contact investigations and latent tuberculosis infection treatment for the 2008 CDC and Modified protocols. At moderate/high rates of latent tuberculosis infection and tuberculosis disease, positive returns on investment indicated each $1.00 spent on tuberculosis contact investigations and latent tuberculosis treatment resulted in more than $1.00 of savings from reduced tuberculosis disease treatment costs. Low rates of latent tuberculosis infection and tuberculosis disease resulted in negative returns on investment, indicating economic losses from tuberculosis disease treatment costs. There were smaller economic losses at low latent tuberculosis infection and tuberculosis disease rates with the Modified protocol in comparison to the 2008 CDC protocol, while both identified comparable numbers of persons at risk for tuberculosis. The Modified protocol for conducting flight-related tuberculosis contact investigations represents a better use of resources and protects public health. Published by Elsevier Ltd.
Coleman, Margaret S.; Marienau, Karen J.; Marano, Nina; Marks, Suzanne M.; Cetron, Martin S.
2017-01-01
Summary Background In 2011, the Centers for Disease Control and Prevention modified its 2008 protocol for flight-related tuberculosis contact investigation initiation. The 2011 Modified protocol was implemented and replaced the 2008 CDC protocol based on comparative epidemiologic and economic analyses; this publication reports the economic analysis results. Methods A return on investment model compared relative changes in tuberculosis disease treatment costs resulting from expenditures on tuberculosis contact investigations and latent tuberculosis infection treatment for the 2008 CDC and Modified protocols. Results At moderate/high rates of latent tuberculosis infection and tuberculosis disease, positive returns on investment indicated each $1.00 spent on tuberculosis contact investigations and latent tuberculosis treatment resulted in more than $1.00 of savings from reduced tuberculosis disease treatment costs. Low rates of latent tuberculosis infection and tuberculosis disease resulted in negative returns on investment, indicating economic losses from tuberculosis disease treatment costs. There were smaller economic losses at low latent tuberculosis infection and tuberculosis disease rates with the Modified protocol in comparison to the 2008 CDC protocol, while both identified comparable numbers of persons at risk for tuberculosis. Conclusion The Modified protocol for conducting flight-related tuberculosis contact investigations represents a better use of resources and protects public health. PMID:24262643
Riley, Robert F; Miller, Chadwick D; Russell, Gregory B; Harper, Erin N; Hiestand, Brian C; Hoekstra, James W; Lefebvre, Cedric W; Nicks, Bret A; Cline, David M; Askew, Kim L; Mahler, Simon A
2017-01-01
The HEART Pathway is a diagnostic protocol designed to identify low-risk patients presenting to the emergency department with chest pain that are safe for early discharge. This protocol has been shown to significantly decrease health care resource utilization compared with usual care. However, the impact of the HEART Pathway on the cost of care has yet to be reported. We performed a cost analysis of patients enrolled in the HEART Pathway trial, which randomized participants to either usual care or the HEART Pathway protocol. For low-risk patients, the HEART Pathway recommended early discharge from the emergency department without further testing. We compared index visit cost, cost at 30 days, and cardiac-related health care cost at 30 days between the 2 treatment arms. Costs for each patient included facility and professional costs. Cost at 30 days included total inpatient and outpatient costs, including the index encounter, regardless of etiology. Cardiac-related health care cost at 30 days included the index encounter and costs adjudicated to be cardiac-related within that period. Two hundred seventy of the 282 patients enrolled in the trial had cost data available for analysis. There was a significant reduction in cost for the HEART Pathway group at 30 days (median cost savings of $216 per individual), which was most evident in low-risk (Thrombolysis In Myocardial Infarction score of 0-1) patients (median savings of $253 per patient) and driven primarily by lower cardiac diagnostic costs in the HEART Pathway group. Using the HEART Pathway as a decision aid for patients with undifferentiated chest pain resulted in significant cost savings. Copyright © 2016 Elsevier Inc. All rights reserved.
Enhancing source location protection in wireless sensor networks
NASA Astrophysics Data System (ADS)
Chen, Juan; Lin, Zhengkui; Wu, Di; Wang, Bailing
2015-12-01
Wireless sensor networks are widely deployed in the internet of things to monitor valuable objects. Once the object is monitored, the sensor nearest to the object which is known as the source informs the base station about the object's information periodically. It is obvious that attackers can capture the object successfully by localizing the source. Thus, many protocols have been proposed to secure the source location. However, in this paper, we examine that typical source location protection protocols generate not only near but also highly localized phantom locations. As a result, attackers can trace the source easily from these phantom locations. To address these limitations, we propose a protocol to enhance the source location protection (SLE). With phantom locations far away from the source and widely distributed, SLE improves source location anonymity significantly. Theory analysis and simulation results show that our SLE provides strong source location privacy preservation and the average safety period increases by nearly one order of magnitude compared with existing work with low communication cost.
Fouda, Usama M; Sayed, Ahmed M
2011-12-01
To compare the efficacy and cost-effectiveness of extended high dose letrozole regimen/HPuFSH-gonadotropin releasing hormone antagonist (GnRHant) protocol with short low dose letrozole regimen/HPuFSH-GnRHant protocol in poor responders undergoing IVF-ET. In this randomized controlled trial, 136 women who responded poorly to GnRH agonist long protocol in their first IVF cycle were randomized into two equal groups using computer generated list and were treated in the second IVF cycle by either extended letrozole regimen (5 mg/day during the first 5 days of cycle and 2.5 mg/day during the subsequent 3 days) combined with HPuFSH-GnRHant protocol or short letrozole regimen (2.5 mg/day from cycle day 3-7) combined with HPuFSH-GnRHant protocol. There were no significant differences between both groups with regard to number of oocytes retrieved and clinical pregnancy rate (5.39 ± 2.08 vs. 5.20 ± 1.88 and 22.06% vs. 16.18%, respectively).The total gonadotropins dose and medications cost per cycle were significantly lower in extended letrozole group (44.87 ± 9.16 vs. 59.97 ± 14.91 ampoules and 616.52 ± 94.97 vs. 746.84 ± 149.21 US Dollars ($), respectively).The cost-effectiveness ratio was 2794 $ in extended letrozole group and 4616 $ in short letrozole group. Extended letrozole regimen/HPuFSH-GnRHant protocol was more cost-effective than short letrozole regimen/HPuFSH-GnRHant protocol in poor responders undergoing IVF-ET.
Mueller, Jenna L.; Asma, Elizabeth; Lam, Christopher T.; Krieger, Marlee S.; Gallagher, Jennifer E.; Erkanli, Alaattin; Hariprasad, Roopa; Malliga, J.S.; Muasher, Lisa C.; Mchome, Bariki; Oneko, Olola; Taylor, Peyton; Venegas, Gino; Wanyoro, Anthony; Mehrotra, Ravi; Schmitt, John W.; Ramanujam, Nimmi
2017-01-01
Objective Barriers to cervical cancer screening in low resource settings include lack of accessible high quality services, high cost, and the need for multiple visits. To address these challenges, we developed a low cost intra-vaginal optical cervical imaging device, the Point of Care Tampon (POCkeT) colposcope, and evaluated whether its performance is comparable to a standard-of-care colposcope. Methods There were two protocols, which included 44 and 18 patients respectively. For the first protocol, white light cervical images were collected in vivo, blinded by device, and sent electronically to 8 physicians from high, middle and low income countries. For the second protocol, green light images were also collected and sent electronically to the highest performing physician from the first protocol who has experience in both a high and low income country. For each image, physicians completed a survey assessing cervix characteristics and severity of precancerous lesions. Corresponding pathology was obtained for all image pairs. Results For the first protocol, average percent agreement between devices was 70% across all physicians. POCkeT and standard-of-care colposcope images had 37% and 51% percent agreement respectively with pathology for high-grade squamous intraepithelial lesions (HSILs). Investigation of HSIL POCkeT images revealed decreased visibility of vascularization and lack of contrast in lesion margins. After changes were made for the second protocol, the two devices achieved similar agreement to pathology for HSIL lesions (55%). Conclusions Based on the exploratory study, physician interpretation of cervix images acquired using a portable, low cost, POCkeT colposcope was comparable to a standard-of-care colposcope. PMID:28263237
Telemedicine using free voice over internet protocol (VoIP) technology.
Miller, David J; Miljkovic, Nikola; Chiesa, Chad; Callahan, John B; Webb, Brad; Boedeker, Ben H
2011-01-01
Though dedicated videoteleconference (VTC) systems deliver high quality, low-latency audio and video for telemedical applications, they require expensive hardware and extensive infrastructure. The purpose of this study was to investigate free commercially available Voice over Internet Protocol (VoIP) software as a low cost alternative for telemedicine.
2002-09-01
Protocol LAN Local Area Network LDAP Lightweight Directory Access Protocol LLQ Low Latency Queuing MAC Media Access Control MarCorSysCom Marine...Description Protocol SIP Session Initiation Protocol SMTP Simple Mail Transfer Protocol SPAWAR Space and Naval Warfare Systems Center SS7 ...PSTN infrastructure previously required to carry the conversation. The cost of accessing the PSTN is thereby eliminated. In cases where Internet
Constructing Cost-Effective and Targetable ICS Honeypots Suited for Production Networks
2015-03-26
introducing Honeyd+ has a marginal impact on performance. Notable findings are that the Raspberry Pi is the preferred hosting platform for the EtherNet/IP... Raspberry Pi or Gumstix, which is a low-cost approach to replicating multiple decoys. One hidden drawback to low- interaction honeypots is the extensive time...EtherNet/IP industrial protocol. Honeyd+ is hosted on a low-cost computing platform ( Raspberry Pi running Raspbian, approximately $50) and a high-cost
Marienau, Karen J; Cramer, Elaine H; Coleman, Margaret S; Marano, Nina; Cetron, Martin S
2014-01-01
In-flight transmission risk of Mycobacterium tuberculosis is not well defined, although studies suggest it is low. The impact of flight-related tuberculosis (TB) contact investigations (TBCIs) on TB prevention and control is not well established, and they compete for resources with activities with established benefits. We sought to determine the risks and cost-benefits of using more restrictive criteria in comparison to the Centers for Disease Control and Prevention (CDC) 2008 protocol for TBCIs. The risk-benefits of a modified CDC protocol were analyzed in comparison to the 2008 CDC protocol using data from flight-related TBCIs conducted in the United States from 2007 through 2009. We predicted the numbers and characteristics of case-travelers that would be identified using each protocol's criteria, and results of the associated passenger-contacts' TB screening tests. The economic analysis compared the costs of TBCIs to avoided costs of TB treatment and mortality using a Return on Investment model. The estimated in-flight transmission risk using a modified CDC protocol was 1.4%-19% versus 1.1%-24% for the 2008 protocol. Numbers of TBCIs and immediate costs to health departments were reduced by half. Long-term cost-benefits were comparable. CDC's modified protocol appears to be a feasible alternative that will conserve public health resources without jeopardizing the public's health. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Lindstrom, Erik Vilhelm Mathias
Gasification of black liquor could drastically increase the flexibility and improve the profit potential of a mature industry. The completed work was focused on research around the economics and benefits of its implementation, utilizing laboratory pulping experiments and process simulation. The separation of sodium and sulfur achieved through gasification of recovered black liquor, can be utilized in processes like modified continuous cooking, split sulfidity and green liquor pretreatment pulping, and polysulfide-anthraquinone pulping, to improve pulp yield and properties. Laboratory pulping protocols have been developed for these modified pulping technologies and different process options evaluated. The process simulation work around BLG has led to the development of a WinGEMS module for the low temperature MTCI steam reforming process, and case studies comparing a simulated conventional kraft process to different process options built around the implementation of a BLG unit operation into the kraft recovery cycle. Pulp yield increases of 1-3% points with improved product quality, and the potential for capital and operating cost savings relative to the conventional kraft process have been demonstrated. Process simulation work has shown that the net variable operating cost for a pulping process using BLGCC is highly dependent on the cost of lime kiln fuel and the selling price of green power to the grid. Under the assumptions taken in the performed case study, the BLGCC process combined with split sulfidity or PSAQ pulping operations had net variable operating cost 2-4% greater than the kraft reference. The influence of the sales price of power to the grid is the most significant cost factor. If a sales price increase to 6 ¢/KWh for green power could be achieved, cost savings of about $40/ODtP could be realized in all investigated BLG processes. Other alternatives to improve the process economics around BLG would be to modify or eliminate the lime kiln unit operations, utilizing high sulfidity green liquor pretreatment, PSAQ with auto-causticization, or converting the process to mini-sulfide sulfite-AQ.
Pereira, A; Sanz, C
2000-10-01
Cost-effectiveness analyses are needed to decide the value of further expansion of the screening protocols for HCV in blood donors. However, such analyses are hampered by imperfect knowledge of the health and economic repercussions of posttransfusion hepatitis C (PTHC). A Monte Carlo simulation of a Markov model representing the outcomes of patients transfused with HCV-infective blood was used to estimate the health and economic impact of PTHC and to calculate the cost-effectiveness ratio of various HCV screening methods. Median survival for hypothetical patients with PTHC and for controls without hepatitis was 11.25 and 11.75 years, respectively. Overall, 12.3 percent of patients receiving HCV-infective blood will develop chronic hepatitis, 9.3 percent will progress to liver failure, and 9. 25 percent will eventually die of liver disease after a median time of 20.75 years (range, 6-70). Ninety-one percent of the infected blood recipients had no reduction in life expectancy due to PTHC, and the average loss per patient was 0.754 years. The present value of the lifetime health costs incurred by patients with PTHC is $6330 per case. HCV antibody testing increases the patients' life expectancy by 20.4 hours per blood collection tested, and it results in net savings by decreasing the number of patients that will require treatment for liver disease in the future. Adding HCV NAT increases the patients' life expectancy by 0.08 hours per blood collection tested, at a cost-effectiveness ratio of $1,829,611 per QALY gained. PTHC has low health benefits because of the advanced age of many blood recipients. Testing donors for HCV antibodies results in net savings for the health care system, despite low health benefits. Adding HCV NAT would produce little additional gain at a very high cost.
NASA Astrophysics Data System (ADS)
Jeng, Albert; Chang, Li-Chung; Chen, Sheng-Hui
There are many protocols proposed for protecting Radio Frequency Identification (RFID) system privacy and security. A number of these protocols are designed for protecting long-term security of RFID system using symmetric key or public key cryptosystem. Others are designed for protecting user anonymity and privacy. In practice, the use of RFID technology often has a short lifespan, such as commodity check out, supply chain management and so on. Furthermore, we know that designing a long-term security architecture to protect the security and privacy of RFID tags information requires a thorough consideration from many different aspects. However, any security enhancement on RFID technology will jack up its cost which may be detrimental to its widespread deployment. Due to the severe constraints of RFID tag resources (e. g., power source, computing power, communication bandwidth) and open air communication nature of RFID usage, it is a great challenge to secure a typical RFID system. For example, computational heavy public key and symmetric key cryptography algorithms (e. g., RSA and AES) may not be suitable or over-killed to protect RFID security or privacy. These factors motivate us to research an efficient and cost effective solution for RFID security and privacy protection. In this paper, we propose a new effective generic binary tree based key agreement protocol (called BKAP) and its variations, and show how it can be applied to secure the low cost and resource constraint RFID system. This BKAP is not a general purpose key agreement protocol rather it is a special purpose protocol to protect privacy, un-traceability and anonymity in a single RFID closed system domain.
Internet Data Delivery for Future Space Missions
NASA Technical Reports Server (NTRS)
Rash, James; Casasanta, Ralph; Hogie, Keith; Hennessy, Joseph F. (Technical Monitor)
2002-01-01
Ongoing work at National Aeronautics and Space Administration Goddard Space Flight Center (NASA/GSFC), seeks to apply standard Internet applications and protocols to meet the technology challenge of future satellite missions. Internet protocols and technologies are under study as a future means to provide seamless dynamic communication among heterogeneous instruments, spacecraft, ground stations, constellations of spacecraft, and science investigators. The primary objective is to design and demonstrate in the laboratory the automated end-to-end transport of files in a simulated dynamic space environment using off-the-shelf, low-cost, commodity-level standard applications and protocols. The demonstrated functions and capabilities will become increasingly significant in the years to come as both earth and space science missions fly more sensors and as the need increases for more network-oriented mission operations. Another element of increasing significance will be the increased cost effectiveness of designing, building, integrating, and operating instruments and spacecraft that will come to the fore as more missions take up the approach of using commodity-level standard communications technologies. This paper describes how an IP (Internet Protocol)-based communication architecture can support all existing operations concepts and how it will enable some new and complex communication and science concepts. The authors identify specific end-to-end data flows from the instruments to the control centers and scientists, and then describe how each data flow can be supported using standard Internet protocols and applications. The scenarios include normal data downlink and command uplink as well as recovery scenarios for both onboard and ground failures. The scenarios are based on an Earth orbiting spacecraft with downlink data rates from 300 Kbps to 4 Mbps. Included examples are based on designs currently being investigated for potential use by the Global Precipitation Measurement (GPM) mission.
Hiding the Source Based on Limited Flooding for Sensor Networks.
Chen, Juan; Lin, Zhengkui; Hu, Ying; Wang, Bailing
2015-11-17
Wireless sensor networks are widely used to monitor valuable objects such as rare animals or armies. Once an object is detected, the source, i.e., the sensor nearest to the object, generates and periodically sends a packet about the object to the base station. Since attackers can capture the object by localizing the source, many protocols have been proposed to protect source location. Instead of transmitting the packet to the base station directly, typical source location protection protocols first transmit packets randomly for a few hops to a phantom location, and then forward the packets to the base station. The problem with these protocols is that the generated phantom locations are usually not only near the true source but also close to each other. As a result, attackers can easily trace a route back to the source from the phantom locations. To address the above problem, we propose a new protocol for source location protection based on limited flooding, named SLP. Compared with existing protocols, SLP can generate phantom locations that are not only far away from the source, but also widely distributed. It improves source location security significantly with low communication cost. We further propose a protocol, namely SLP-E, to protect source location against more powerful attackers with wider fields of vision. The performance of our SLP and SLP-E are validated by both theoretical analysis and simulation results.
Cost-effective treatment of low-risk carcinoma not invading bladder muscle.
Green, David A; Rink, Michael; Cha, Eugene K; Xylinas, Evanguelos; Chughtai, Bilal; Scherr, Douglas S; Shariat, Shahrokh F; Lee, Richard K
2013-03-01
Study Type - Therapy (cost effectiveness analysis) Level of Evidence 2a What's known on the subject? and What does the study add? Bladder cancer is one of the costliest malignancies to treat throughout the life of a patient. The most cost-effective management for low-risk non-muscle-invasive bladder cancer is not known. The current study shows that employing cystoscopic office fulguration for low-risk appearing bladder cancer recurrences can materially impact the cost-effectiveness of therapy. In a follow-up protocol where office fulguration is routinely employed for low-risk bladder cancers, peri-operative intravesical chemotherapy may not provide any additional cost-effectiveness benefit. To examine the cost-effectiveness of fulguration vs transurethral resection of bladder tumour (TURBT) with and without perioperative intravesical chemotherapy (PIC) for managing low-risk carcinoma not invading bladder muscle (NMIBC). Low-risk NMIBC carries a low progression rate, lending support to the use of office-based fulguration for small recurrences rather than traditional TURBT. A Markov state transition model was created to simulate treatment of NMIBC with vs without PIC, with recurrence treated by formal TURBT vs treatment with fulguration. Costing data were obtained from the Medicare Resource Based Relative Value Scale. Data regarding the success of PIC were obtained from the peer-reviewed literature, as were corresponding utilities for bladder cancer-related procedures. Sensitivity analyses were performed. At 5-year follow-up, a strategy of fulguration without PIC was the most cost-effective (mean cost-effectiveness = US $654.8/quality-adjusted life year), despite a lower recurrence rate with PIC. Both fulguration strategies dominated each TURBT strategy. Sensitivity analysis showed that fulguration without PIC dominated all other strategies when the recurrence rate after PIC was increased to ≥14.2% per year. Similarly, the cost-effectiveness of TURBT becomes more competitive with fulguration when the total cost of TURBT declines < US $1175. The present study shows that fulguration without PIC was the most cost-effective strategy for treating low-risk NMIBC. The effectiveness of PIC and the cost of TURBT can materially impact the cost-effectiveness of the different management strategies. These results should be considered in treatment decisions in the context of preserving oncological control. © 2012 BJU INTERNATIONAL.
Need low-cost networking? Consider DeviceNet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moss, W.H.
1996-11-01
The drive to reduce production costs and optimize system performance in manufacturing facilities causes many end users to invest in network solutions. Because of distinct differences between the way tasks are performed and the way data are handled for various applications, it is clear than more than one network will be needed in most facilities. What is not clear is which network is most appropriate for a given application. The information layer is the link between automation and information environments via management information systems (MISs) and manufacturing execution systems (MESs) and manufacturing execution systems (MESs). Here the market has chosenmore » a de facto standard in Ethernet, primarily transmission control protocol/internet protocol (TCP/IP) and secondarily manufacturing messaging system (MMS). There is no single standard at the device layer. However, the DeviceNet communication standard has made strides to reach this goal. This protocol eliminates expensive hardwiring and provides improved communication between devices and important device-level diagnostics not easily accessible or available through hardwired I/O interfaces. DeviceNet is a low-cost communications link connecting industrial devices to a network. Many original equipment manufacturers and end users have chosen the DeviceNet platform for several reasons, but most frequently because of four key features: interchangeability; low cost; advanced diagnostics; insert devices under power.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Sangroh; Yoo, Sua; Yin Fangfang
2010-07-15
Purpose: To assess imaging dose of partial and full-angle kilovoltage CBCT scan protocols and to evaluate image quality for each protocol. Methods: The authors obtained the CT dose index (CTDI) of the kilovoltage CBCT protocols in an on-board imager by ion chamber (IC) measurements and Monte Carlo (MC) simulations. A total of six new CBCT scan protocols were evaluated: Standard-dose head (100 kVp, 151 mA s, partial-angle), low-dose head (100 kVp, 75 mA s, partial-angle), high-quality head (100 kVp, 754 mA s, partial-angle), pelvis (125 kVp, 706 mA s, full-angle), pelvis spotlight (125 kVp, 752 mA s, partial-angle), and low-dosemore » thorax (110 kVp, 271 mA s, full-angle). Using the point dose method, various CTDI values were calculated by (1) the conventional weighted CTDI (CTDI{sub w}) calculation and (2) Bakalyar's method (CTDI{sub wb}). The MC simulations were performed to obtain the CTDI{sub w} and CTDI{sub wb}, as well as from (3) central slice averaging (CTDI{sub 2D}) and (4) volume averaging (CTDI{sub 3D}) techniques. The CTDI values of the new protocols were compared to those of the old protocols (full-angle CBCT protocols). Image quality of the new protocols was evaluated following the CBCT image quality assurance (QA) protocol [S. Yoo et al., ''A quality assurance program for the on-board imager registered ,'' Med. Phys. 33(11), 4431-4447 (2006)] testing Hounsfield unit (HU) linearity, spatial linearity/resolution, contrast resolution, and HU uniformity. Results: The CTDI{sub w} were found as 6.0, 3.2, 29.0, 25.4, 23.8, and 7.7 mGy for the new protocols, respectively. The CTDI{sub w} and CTDI{sub wb} differed within +3% between IC measurements and MC simulations. Method (2) results were within {+-}12% of method (1). In MC simulations, the CTDI{sub w} and CTDI{sub wb} were comparable to the CTDI{sub 2D} and CTDI{sub 3D} with the differences ranging from -4.3% to 20.6%. The CTDI{sub 3D} were smallest among all the CTDI values. CTDI{sub w} of the new protocols were found as {approx}14 times lower for standard head scan and 1.8 times lower for standard body scan than the old protocols, respectively. In the image quality QA tests, all the protocols except low-dose head and low-dose thorax protocols were within the tolerance in the HU verification test. The HU value for the two protocols was always higher than the nominal value. All the protocols passed the spatial linearity/resolution and HU uniformity tests. In the contrast resolution test, only high-quality head and pelvis scan protocols were within the tolerance. In addition, crescent effect was found in the partial-angle scan protocols. Conclusions: The authors found that CTDI{sub w} of the new CBCT protocols has been significantly reduced compared to the old protocols with acceptable image quality. The CTDI{sub w} values in the point dose method were close to the volume averaging method within 9%-21% for all the CBCT scan protocols. The Bakalyar's method produced more accurate dose estimation within 14%. The HU inaccuracy from low-dose head and low-dose thorax protocols can render incorrect dose results in the treatment planning system. When high soft-tissue contrast data are desired, high-quality head or pelvis scan protocol is recommended depending on the imaging area. The point dose method can be applicable to estimate CBCT dose with reasonable accuracy in the clinical environment.« less
Authentication of Radio Frequency Identification Devices Using Electronic Characteristics
ERIC Educational Resources Information Center
Chinnappa Gounder Periaswamy, Senthilkumar
2010-01-01
Radio frequency identification (RFID) tags are low-cost devices that are used to uniquely identify the objects to which they are attached. Due to the low cost and size that is driving the technology, a tag has limited computational capabilities and resources. This limitation makes the implementation of conventional security protocols to prevent…
An Open Source Low-Cost Wireless Control System for a Forced Circulation Solar Plant
Salamone, Francesco; Belussi, Lorenzo; Danza, Ludovico; Ghellere, Matteo; Meroni, Italo
2015-01-01
The article describes the design phase, development and practical application of a low-cost control system for a forced circulation solar plant in an outdoor test cell located near Milan. Such a system provides for the use of an electric pump for the circulation of heat transfer fluid connecting the solar thermal panel to the storage tank. The running plant temperatures are the fundamental parameter to evaluate the system performance such as proper operation, and the control and management system has to consider these parameters. A solar energy-powered wireless-based smart object was developed, able to monitor the running temperatures of a solar thermal system and aimed at moving beyond standard monitoring approaches to achieve a low-cost and customizable device, even in terms of installation in different environmental conditions. To this end, two types of communications were used: the first is a low-cost communication based on the ZigBee protocol used for control purposes, so that it can be customized according to specific needs, while the second is based on a Bluetooth protocol used for data display. PMID:26556356
An Open Source Low-Cost Wireless Control System for a Forced Circulation Solar Plant.
Salamone, Francesco; Belussi, Lorenzo; Danza, Ludovico; Ghellere, Matteo; Meroni, Italo
2015-11-05
The article describes the design phase, development and practical application of a low-cost control system for a forced circulation solar plant in an outdoor test cell located near Milan. Such a system provides for the use of an electric pump for the circulation of heat transfer fluid connecting the solar thermal panel to the storage tank. The running plant temperatures are the fundamental parameter to evaluate the system performance such as proper operation, and the control and management system has to consider these parameters. A solar energy-powered wireless-based smart object was developed, able to monitor the running temperatures of a solar thermal system and aimed at moving beyond standard monitoring approaches to achieve a low-cost and customizable device, even in terms of installation in different environmental conditions. To this end, two types of communications were used: the first is a low-cost communication based on the ZigBee protocol used for control purposes, so that it can be customized according to specific needs, while the second is based on a Bluetooth protocol used for data display.
A Benefit Analysis of Using a Low-Cost Flight Simulator for the MH-60R
2016-09-01
NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release. Distribution is unlimited. A BENEFIT ...2016 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE A BENEFIT ANALYSIS OF USING A LOW- COST FLIGHT SIMULATOR FOR THE MH... BENEFIT ANALYSIS OF USING A LOW- COST FLIGHT SIMULATOR FOR THE MH-60R J. Gregory Zilai Lieutenant, United States Navy B.S., United States Naval
PROTOCOL TO EVALUATE THE MOISTURE DURABILITY OF ENERGY-EFFICIENT WALLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boudreaux, Philip R; Pallin, Simon B; Hun, Diana E
Walls account for about 8% of the energy used in residential buildings. This energy penalty can be reduced with higher insulation levels and increased airtightness. However, these measures can compromise the moisture durability and long-term performance of wall assemblies because they can lead to lower moisture tolerance due to reduced drying potential. To avert these problems, a moisture durability protocol was developed to evaluate the probability that an energy-efficient wall design will experience mold growth. This protocol examines the effects of moisture sources in walls through a combination of simulations and lab experiments, uses the mold growth index as themore » moisture durability indicator, and is based on a probabilistic approach that utilizes stochastically varying input parameters. The simulation tools used include a new validated method for taking into account the effects of air leakage in wall assemblies This paper provides an overview of the developed protocol, discussion of the probabilistic simulation approach and describes results from the evaluation of two wall assemblies in Climate Zones 2, 4, and 6. The protocol will be used to supply builders with wall designs that are energy efficient, moisture durable and cost-effective.« less
Faraghat, Shabnam A; Hoettges, Kai F; Steinbach, Max K; van der Veen, Daan R; Brackenbury, William J; Henslee, Erin A; Labeed, Fatima H; Hughes, Michael P
2017-05-02
Currently, cell separation occurs almost exclusively by density gradient methods and by fluorescence- and magnetic-activated cell sorting (FACS/MACS). These variously suffer from lack of specificity, high cell loss, use of labels, and high capital/operating cost. We present a dielectrophoresis (DEP)-based cell-separation method, using 3D electrodes on a low-cost disposable chip; one cell type is allowed to pass through the chip whereas the other is retained and subsequently recovered. The method advances usability and throughput of DEP separation by orders of magnitude in throughput, efficiency, purity, recovery (cells arriving in the correct output fraction), cell losses (those which are unaccounted for at the end of the separation), and cost. The system was evaluated using three example separations: live and dead yeast; human cancer cells/red blood cells; and rodent fibroblasts/red blood cells. A single-pass protocol can enrich cells with cell recovery of up to 91.3% at over 300,000 cells per second with >3% cell loss. A two-pass protocol can process 300,000,000 cells in under 30 min, with cell recovery of up to 96.4% and cell losses below 5%, an effective processing rate >160,000 cells per second. A three-step protocol is shown to be effective for removal of 99.1% of RBCs spiked with 1% cancer cells while maintaining a processing rate of ∼170,000 cells per second. Furthermore, the self-contained and low-cost nature of the separator device means that it has potential application in low-contamination applications such as cell therapies, where good manufacturing practice compatibility is of paramount importance.
Tobe, Shanan S; Bailey, Stuart; Govan, James; Welch, Lindsey A
2013-03-01
Although poaching is a common wildlife crime, the high and prohibitive cost of specialised animal testing means that many cases are left un-investigated. We previously described a novel approach to wildlife crime investigation that looked at the identification of human DNA on poached animal remains (Tobe, Govan and Welch, 2011). Human DNA was successfully isolated and amplified from simulated poaching incidents, however a low template protocol was required which made this method unsuitable for use in many laboratories. We now report on an optimised recovery and amplification protocol which removes the need for low template analysis. Samples from 10 deer (40 samples total - one from each leg) analysed in the original study were re-analysed in the current study with an additional 11 deer samples. Four samples analysed using Chelex did not show any results and a new method was devised whereby the available DNA was concentrated. By combining the DNA extracts from all tapings of the same deer remains followed by concentration, the recovered quantity of human DNA was found to be 29.5pg±43.2pg, 31× greater than the previous study. The use of the Investigator Decaplex SE (QIAGEN) STR kit provided better results in the form of more complete profiles than did the AmpFℓSTR® SGM Plus® kit at 30cycles (Applied Biosystems). Re-analysis of the samples from the initial study using the new, optimised protocol resulted in an average increase of 18% of recovered alleles. Over 17 samples, 71% of the samples analysed using the optimised protocol showed sufficient amplification for comparison to a reference profile and gave match probabilities ranging from 7.7690×10(-05) to 2.2706×10(-14). The removal of low template analysis means this optimised method provides evidence of high probative value and is suitable for immediate use in forensic laboratories. All methods and techniques used are standard and are compatible with current SOPs. As no high cost non-human DNA analysis is required the overall process is no more expensive than the investigation of other volume crime samples. The technique is suitable for immediate use in poaching incidents. Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
Williams, Cylie; Kiegaldie, Debra; Kaplonyi, Jessica; Haines, Terry
2016-01-01
Introduction Simulation-based education (SBE) is now commonly used across health professional disciplines to teach a range of skills. The evidence base supporting the effectiveness of this approach for improving patient health outcomes is relatively narrow, focused mainly on the development of procedural skills. However, there are other simulation approaches used to support non-procedure specific skills that are in need of further investigation. This cluster, cross-over randomised controlled trial with a concurrent economic evaluation (cost per fall prevented) trial will evaluate the effectiveness, cost-effectiveness and student experience of health professional students undertaking simulation training for the prevention of falls among hospitalised inpatients. This research will target the students within the established undergraduate student placements of Monash University medicine, nursing and allied health across Peninsula Health acute and subacute inpatient wards. Methods and analysis The intervention will train the students in how to provide the Safe Recovery program, the only single intervention approach demonstrated to reduce falls in hospitals. This will involve redevelopment of the Safe Recovery program into a one-to-many participant SBE program, so that groups of students learn the communication skills and falls prevention knowledge necessary for delivery of the program. The primary outcome of this research will be patient falls across participating inpatient wards, with secondary outcomes including student satisfaction with the SBE and knowledge gain, ward-level practice change and cost of acute/rehabilitation care for each patient measured using clinical costing data. Ethics and dissemination The Human Research Ethics Committees of Peninsula Health (LRR/15/PH/11) and Monash University (CF15/3523-2015001384) have approved this research. The participant information and consent forms provide information on privacy, storage of results and dissemination. Registration of this trial has been completed with the Australian and New Zealand Clinical Trials Registry: ACTRN12615000817549. This study protocol has been prepared according to the Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT) checklist. Trial registration number ACTRN12615000817549; Pre-results. PMID:27256087
Energy-efficient boarder node medium access control protocol for wireless sensor networks.
Razaque, Abdul; Elleithy, Khaled M
2014-03-12
This paper introduces the design, implementation, and performance analysis of the scalable and mobility-aware hybrid protocol named boarder node medium access control (BN-MAC) for wireless sensor networks (WSNs), which leverages the characteristics of scheduled and contention-based MAC protocols. Like contention-based MAC protocols, BN-MAC achieves high channel utilization, network adaptability under heavy traffic and mobility, and low latency and overhead. Like schedule-based MAC protocols, BN-MAC reduces idle listening time, emissions, and collision handling at low cost at one-hop neighbor nodes and achieves high channel utilization under heavy network loads. BN-MAC is particularly designed for region-wise WSNs. Each region is controlled by a boarder node (BN), which is of paramount importance. The BN coordinates with the remaining nodes within and beyond the region. Unlike other hybrid MAC protocols, BN-MAC incorporates three promising models that further reduce the energy consumption, idle listening time, overhearing, and congestion to improve the throughput and reduce the latency. One of the models used with BN-MAC is automatic active and sleep (AAS), which reduces the ideal listening time. When nodes finish their monitoring process, AAS lets them automatically go into the sleep state to avoid the idle listening state. Another model used in BN-MAC is the intelligent decision-making (IDM) model, which helps the nodes sense the nature of the environment. Based on the nature of the environment, the nodes decide whether to use the active or passive mode. This decision power of the nodes further reduces energy consumption because the nodes turn off the radio of the transceiver in the passive mode. The third model is the least-distance smart neighboring search (LDSNS), which determines the shortest efficient path to the one-hop neighbor and also provides cross-layering support to handle the mobility of the nodes. The BN-MAC also incorporates a semi-synchronous feature with a low duty cycle, which is advantageous for reducing the latency and energy consumption for several WSN application areas to improve the throughput. BN-MAC uses a unique window slot size to enhance the contention resolution issue for improved throughput. BN-MAC also prefers to communicate within a one-hop destination using Anycast, which maintains load balancing to maintain network reliability. BN-MAC is introduced with the goal of supporting four major application areas: monitoring and behavioral areas, controlling natural disasters, human-centric applications, and tracking mobility and static home automation devices from remote places. These application areas require a congestion-free mobility-supported MAC protocol to guarantee reliable data delivery. BN-MAC was evaluated using network simulator-2 (ns2) and compared with other hybrid MAC protocols, such as Zebra medium access control (Z-MAC), advertisement-based MAC (A-MAC), Speck-MAC, adaptive duty cycle SMAC (ADC-SMAC), and low-power real-time medium access control (LPR-MAC). The simulation results indicate that BN-MAC is a robust and energy-efficient protocol that outperforms other hybrid MAC protocols in the context of quality of service (QoS) parameters, such as energy consumption, latency, throughput, channel access time, successful delivery rate, coverage efficiency, and average duty cycle.
Energy-Efficient Boarder Node Medium Access Control Protocol for Wireless Sensor Networks
Razaque, Abdul; Elleithy, Khaled M.
2014-01-01
This paper introduces the design, implementation, and performance analysis of the scalable and mobility-aware hybrid protocol named boarder node medium access control (BN-MAC) for wireless sensor networks (WSNs), which leverages the characteristics of scheduled and contention-based MAC protocols. Like contention-based MAC protocols, BN-MAC achieves high channel utilization, network adaptability under heavy traffic and mobility, and low latency and overhead. Like schedule-based MAC protocols, BN-MAC reduces idle listening time, emissions, and collision handling at low cost at one-hop neighbor nodes and achieves high channel utilization under heavy network loads. BN-MAC is particularly designed for region-wise WSNs. Each region is controlled by a boarder node (BN), which is of paramount importance. The BN coordinates with the remaining nodes within and beyond the region. Unlike other hybrid MAC protocols, BN-MAC incorporates three promising models that further reduce the energy consumption, idle listening time, overhearing, and congestion to improve the throughput and reduce the latency. One of the models used with BN-MAC is automatic active and sleep (AAS), which reduces the ideal listening time. When nodes finish their monitoring process, AAS lets them automatically go into the sleep state to avoid the idle listening state. Another model used in BN-MAC is the intelligent decision-making (IDM) model, which helps the nodes sense the nature of the environment. Based on the nature of the environment, the nodes decide whether to use the active or passive mode. This decision power of the nodes further reduces energy consumption because the nodes turn off the radio of the transceiver in the passive mode. The third model is the least-distance smart neighboring search (LDSNS), which determines the shortest efficient path to the one-hop neighbor and also provides cross-layering support to handle the mobility of the nodes. The BN-MAC also incorporates a semi-synchronous feature with a low duty cycle, which is advantageous for reducing the latency and energy consumption for several WSN application areas to improve the throughput. BN-MAC uses a unique window slot size to enhance the contention resolution issue for improved throughput. BN-MAC also prefers to communicate within a one-hop destination using Anycast, which maintains load balancing to maintain network reliability. BN-MAC is introduced with the goal of supporting four major application areas: monitoring and behavioral areas, controlling natural disasters, human-centric applications, and tracking mobility and static home automation devices from remote places. These application areas require a congestion-free mobility-supported MAC protocol to guarantee reliable data delivery. BN-MAC was evaluated using network simulator-2 (ns2) and compared with other hybrid MAC protocols, such as Zebra medium access control (Z-MAC), advertisement-based MAC (A-MAC), Speck-MAC, adaptive duty cycle SMAC (ADC-SMAC), and low-power real-time medium access control (LPR-MAC). The simulation results indicate that BN-MAC is a robust and energy-efficient protocol that outperforms other hybrid MAC protocols in the context of quality of service (QoS) parameters, such as energy consumption, latency, throughput, channel access time, successful delivery rate, coverage efficiency, and average duty cycle. PMID:24625737
Chang, Yuchao; Tang, Hongying; Cheng, Yongbo; Zhao, Qin; Yuan, Baoqing Li andXiaobing
2017-07-19
Routing protocols based on topology control are significantly important for improving network longevity in wireless sensor networks (WSNs). Traditionally, some WSN routing protocols distribute uneven network traffic load to sensor nodes, which is not optimal for improving network longevity. Differently to conventional WSN routing protocols, we propose a dynamic hierarchical protocol based on combinatorial optimization (DHCO) to balance energy consumption of sensor nodes and to improve WSN longevity. For each sensor node, the DHCO algorithm obtains the optimal route by establishing a feasible routing set instead of selecting the cluster head or the next hop node. The process of obtaining the optimal route can be formulated as a combinatorial optimization problem. Specifically, the DHCO algorithm is carried out by the following procedures. It employs a hierarchy-based connection mechanism to construct a hierarchical network structure in which each sensor node is assigned to a special hierarchical subset; it utilizes the combinatorial optimization theory to establish the feasible routing set for each sensor node, and takes advantage of the maximum-minimum criterion to obtain their optimal routes to the base station. Various results of simulation experiments show effectiveness and superiority of the DHCO algorithm in comparison with state-of-the-art WSN routing algorithms, including low-energy adaptive clustering hierarchy (LEACH), hybrid energy-efficient distributed clustering (HEED), genetic protocol-based self-organizing network clustering (GASONeC), and double cost function-based routing (DCFR) algorithms.
The Traffic Adaptive Data Dissemination (TrAD) Protocol for both Urban and Highway Scenarios.
Tian, Bin; Hou, Kun Mean; Zhou, Haiying
2016-06-21
The worldwide economic cost of road crashes and injuries is estimated to be US$518 billion per year and the annual congestion cost in France is estimated to be €5.9 billion. Vehicular Ad hoc Networks (VANETs) are one solution to improve transport features such as traffic safety, traffic jam and infotainment on wheels, where a great number of event-driven messages need to be disseminated in a timely way in a region of interest. In comparison with traditional wireless networks, VANETs have to consider the highly dynamic network topology and lossy links due to node mobility. Inter-Vehicle Communication (IVC) protocols are the keystone of VANETs. According to our survey, most of the proposed IVC protocols focus on either highway or urban scenarios, but not on both. Furthermore, too few protocols, considering both scenarios, can achieve high performance. In this paper, an infrastructure-less Traffic Adaptive data Dissemination (TrAD) protocol which takes into account road traffic and network traffic status for both highway and urban scenarios will be presented. TrAD has double broadcast suppression techniques and is designed to adapt efficiently to the irregular road topology. The performance of the TrAD protocol was evaluated quantitatively by means of realistic simulations taking into account different real road maps, traffic routes and vehicular densities. The obtained simulation results show that TrAD is more efficient in terms of packet delivery ratio, number of transmissions and delay in comparison with the performance of three well-known reference protocols. Moreover, TrAD can also tolerate a reasonable degree of GPS drift and still achieve efficient data dissemination.
The Traffic Adaptive Data Dissemination (TrAD) Protocol for both Urban and Highway Scenarios
Tian, Bin; Hou, Kun Mean; Zhou, Haiying
2016-01-01
The worldwide economic cost of road crashes and injuries is estimated to be US$518 billion per year and the annual congestion cost in France is estimated to be €5.9 billion. Vehicular Ad hoc Networks (VANETs) are one solution to improve transport features such as traffic safety, traffic jam and infotainment on wheels, where a great number of event-driven messages need to be disseminated in a timely way in a region of interest. In comparison with traditional wireless networks, VANETs have to consider the highly dynamic network topology and lossy links due to node mobility. Inter-Vehicle Communication (IVC) protocols are the keystone of VANETs. According to our survey, most of the proposed IVC protocols focus on either highway or urban scenarios, but not on both. Furthermore, too few protocols, considering both scenarios, can achieve high performance. In this paper, an infrastructure-less Traffic Adaptive data Dissemination (TrAD) protocol which takes into account road traffic and network traffic status for both highway and urban scenarios will be presented. TrAD has double broadcast suppression techniques and is designed to adapt efficiently to the irregular road topology. The performance of the TrAD protocol was evaluated quantitatively by means of realistic simulations taking into account different real road maps, traffic routes and vehicular densities. The obtained simulation results show that TrAD is more efficient in terms of packet delivery ratio, number of transmissions and delay in comparison with the performance of three well-known reference protocols. Moreover, TrAD can also tolerate a reasonable degree of GPS drift and still achieve efficient data dissemination. PMID:27338393
Yousaf, Sidrah; Javaid, Nadeem; Qasim, Umar; Alrajeh, Nabil; Khan, Zahoor Ali; Ahmed, Mansoor
2016-02-24
In this study, we analyse incremental cooperative communication for wireless body area networks (WBANs) with different numbers of relays. Energy efficiency (EE) and the packet error rate (PER) are investigated for different schemes. We propose a new cooperative communication scheme with three-stage relaying and compare it to existing schemes. Our proposed scheme provides reliable communication with less PER at the cost of surplus energy consumption. Analytical expressions for the EE of the proposed three-stage cooperative communication scheme are also derived, taking into account the effect of PER. Later on, the proposed three-stage incremental cooperation is implemented in a network layer protocol; enhanced incremental cooperative critical data transmission in emergencies for static WBANs (EInCo-CEStat). Extensive simulations are conducted to validate the proposed scheme. Results of incremental relay-based cooperative communication protocols are compared to two existing cooperative routing protocols: cooperative critical data transmission in emergencies for static WBANs (Co-CEStat) and InCo-CEStat. It is observed from the simulation results that incremental relay-based cooperation is more energy efficient than the existing conventional cooperation protocol, Co-CEStat. The results also reveal that EInCo-CEStat proves to be more reliable with less PER and higher throughput than both of the counterpart protocols. However, InCo-CEStat has less throughput with a greater stability period and network lifetime. Due to the availability of more redundant links, EInCo-CEStat achieves a reduced packet drop rate at the cost of increased energy consumption.
Yousaf, Sidrah; Javaid, Nadeem; Qasim, Umar; Alrajeh, Nabil; Khan, Zahoor Ali; Ahmed, Mansoor
2016-01-01
In this study, we analyse incremental cooperative communication for wireless body area networks (WBANs) with different numbers of relays. Energy efficiency (EE) and the packet error rate (PER) are investigated for different schemes. We propose a new cooperative communication scheme with three-stage relaying and compare it to existing schemes. Our proposed scheme provides reliable communication with less PER at the cost of surplus energy consumption. Analytical expressions for the EE of the proposed three-stage cooperative communication scheme are also derived, taking into account the effect of PER. Later on, the proposed three-stage incremental cooperation is implemented in a network layer protocol; enhanced incremental cooperative critical data transmission in emergencies for static WBANs (EInCo-CEStat). Extensive simulations are conducted to validate the proposed scheme. Results of incremental relay-based cooperative communication protocols are compared to two existing cooperative routing protocols: cooperative critical data transmission in emergencies for static WBANs (Co-CEStat) and InCo-CEStat. It is observed from the simulation results that incremental relay-based cooperation is more energy efficient than the existing conventional cooperation protocol, Co-CEStat. The results also reveal that EInCo-CEStat proves to be more reliable with less PER and higher throughput than both of the counterpart protocols. However, InCo-CEStat has less throughput with a greater stability period and network lifetime. Due to the availability of more redundant links, EInCo-CEStat achieves a reduced packet drop rate at the cost of increased energy consumption. PMID:26927104
Technology developments integrating a space network communications testbed
NASA Technical Reports Server (NTRS)
Kwong, Winston; Jennings, Esther; Clare, Loren; Leang, Dee
2006-01-01
As future manned and robotic space explorations missions involve more complex systems, it is essential to verify, validate, and optimize such systems through simulation and emulation in a low cost testbed environment. The goal of such a testbed is to perform detailed testing of advanced space and ground communications networks, technologies, and client applications that are essential for future space exploration missions. We describe the development of new technologies enhancing our Multi-mission Advanced Communications Hybrid Environment for Test and Evaluation (MACHETE) that enables its integration in a distributed space communications testbed. MACHETE combines orbital modeling, link analysis, and protocol and service modeling to quantify system performance based on comprehensive considerations of different aspects of space missions.
Practical quantum appointment scheduling
NASA Astrophysics Data System (ADS)
Touchette, Dave; Lovitz, Benjamin; Lütkenhaus, Norbert
2018-04-01
We propose a protocol based on coherent states and linear optics operations for solving the appointment-scheduling problem. Our main protocol leaks strictly less information about each party's input than the optimal classical protocol, even when considering experimental errors. Along with the ability to generate constant-amplitude coherent states over two modes, this protocol requires the ability to transfer these modes back-and-forth between the two parties multiple times with very low losses. The implementation requirements are thus still challenging. Along the way, we develop tools to study quantum information cost of interactive protocols in the finite regime.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thor, Daniel; Brismar, Torkel B., E-mail: torkel.brismar@gmail.com; Fischer, Michael A.
Purpose: To evaluate the potential of low tube voltage dual source (DS) single energy (SE) and dual energy (DE) computed tomography (CT) to reduce contrast media (CM) dose in adult abdominal examinations of various sizes while maintaining soft tissue and iodine contrast-to-noise ratio (CNR). Methods: Four abdominal phantoms simulating a body mass index of 16 to 35 kg/m{sup 2} with four inserted syringes of 0, 2, 4, and 8 mgI/ml CM were scanned using a 64-slice DS-CT scanner. Six imaging protocols were used; one single source (SS) reference protocol (120 kV, 180 reference mAs), four low kV SE protocols (70more » and 80 kV using both SS and DS), and one DE protocol at 80/140 kV. Potential CM reduction with unchanged CNRs relative to the 120 kV protocol was calculated along with the corresponding increase in radiation dose. Results: The potential contrast media reductions were determined to be approximately 53% for DS 70 kV, 51% for SS 70 kV, 44% for DS 80 kV, 40% for SS 80 kV, and 20% for DE (all differences were significant, P < 0.05). Constant CNR could be achieved by using DS 70 kV for small to medium phantom sizes (16–26 kg/m{sup 2}) and for all sizes (16–35 kg/m{sup 2}) when using DS 80 kV and DE. Corresponding radiation doses increased by 60%–107%, 23%–83%, and 6%–12%, respectively. Conclusions: DS single energy CT can be used to reduce CM dose by 44%–53% with maintained CNR in adult abdominal examinations at the cost of an increased radiation dose. DS dual-energy CT allows reduction of CM dose by 20% at similar radiation dose as compared to a standard 120 kV single source.« less
NPSNET: Aural cues for virtual world immersion
NASA Astrophysics Data System (ADS)
Dahl, Leif A.
1992-09-01
NPSNET is a low-cost visual and aural simulation system designed and implemented at the Naval Postgraduate School. NPSNET is an example of a virtual world simulation environment that incorporates real-time aural cues through software-hardware interaction. In the current implementation of NPSNET, a graphics workstation functions in the sound server role which involves sending and receiving networked sound message packets across a Local Area Network, composed of multiple graphics workstations. The network messages contain sound file identification information that is transmitted from the sound server across an RS-422 protocol communication line to a serial to Musical Instrument Digital Interface (MIDI) converter. The MIDI converter, in turn relays the sound byte to a sampler, an electronic recording and playback device. The sampler correlates the hexadecimal input to a specific note or stored sound and sends it as an audio signal to speakers via an amplifier. The realism of a simulation is improved by involving multiple participant senses and removing external distractions. This thesis describes the incorporation of sound as aural cues, and the enhancement they provide in the virtual simulation environment of NPSNET.
NASA Astrophysics Data System (ADS)
Don, Steven; Whiting, Bruce R.; Hildebolt, Charles F.; Sehnert, W. James; Ellinwood, Jacquelyn S.; Töpfer, Karin; Masoumzadeh, Parinaz; Kraus, Richard A.; Kronemer, Keith A.; Herman, Thomas; McAlister, William H.
2006-03-01
The risk of radiation exposure is greatest for pediatric patients and, thus, there is a great incentive to reduce the radiation dose used in diagnostic procedures for children to "as low as reasonably achievable" (ALARA). Testing of low-dose protocols presents a dilemma, as it is unethical to repeatedly expose patients to ionizing radiation in order to determine optimum protocols. To overcome this problem, we have developed a computed-radiography (CR) dose-reduction simulation tool that takes existing images and adds synthetic noise to create realistic images that correspond to images generated with lower doses. The objective of our study was to determine the extent to which simulated, low-dose images corresponded with original (non-simulated) low-dose images. To make this determination, we created pneumothoraces of known volumes in five neonate cadavers and obtained images of the neonates at 10 mR, 1 mR and 0.1 mR (as measured at the cassette plate). The 10-mR exposures were considered "relatively-noise-free" images. We used these 10 mR-images and our simulation tool to create simulated 0.1- and 1-mR images. For the simulated and original images, we identified regions of interest (ROI) of the entire chest, free-in-air region, and liver. We compared the means and standard deviations of the ROI grey-scale values of the simulated and original images with paired t tests. We also had observers rate simulated and original images for image quality and for the presence or absence of pneumothoraces. There was no statistically significant difference in grey-scale-value means nor standard deviations between simulated and original entire chest ROI regions. The observer performance suggests that an exposure >=0.2 mR is required to detect the presence or absence of pneumothoraces. These preliminary results indicate that the use of the simulation tool is promising for achieving ALARA exposures in children.
Performance and analysis of MAC protocols based on application
NASA Astrophysics Data System (ADS)
Yadav, Ravi; Daniel, A. K.
2018-04-01
Wireless Sensor Network is one of the rapid emerging technology in recent decades. It covers large application area as civilian and military. Wireless Sensor Network primary consists of sensor nodes having low-power, low cost and multifunctional activities to collaborates and communicates via wireless medium. The deployment of sensor nodes are adhoc in nature, so sensor nodes are auto organize themselves in such a way to communicate with each other. The characteristics make more challenging areas on WSNs. This paper gives overview about characteristics of WSNs, Architecture and Contention Based MAC protocol. The paper present analysis of various protocol based on performance.
Open Source Cybersecurity for the 21st Century
2013-03-01
would eventually develop into Transmission Control Protocol/Internet Protocol ( TCP /IP) based on the following ground rules:12 Each distinct...The internet’s design permits any device conforming to modern day protocol standards ( TCP /IP being the most prevalent) to communicate across the... factors , coupled with the internet’s global reach and low cost of entry, are what make securing the cyber domain one of the most complex challenges we
Optimizing Data Centre Energy and Environmental Costs
NASA Astrophysics Data System (ADS)
Aikema, David Hendrik
Data centres use an estimated 2% of US electrical power which accounts for much of their total cost of ownership. This consumption continues to grow, further straining power grids attempting to integrate more renewable energy. This dissertation focuses on assessing and reducing data centre environmental and financial costs. Emissions of projects undertaken to lower the data centre environmental footprints can be assessed and the emission reduction projects compared using an ISO-14064-2-compliant greenhouse gas reduction protocol outlined herein. I was closely involved with the development of the protocol. Full lifecycle analysis and verifying that projects exceed business-as-usual expectations are addressed, and a test project is described. Consuming power when it is low cost or when renewable energy is available can be used to reduce the financial and environmental costs of computing. Adaptation based on the power price showed 10--50% potential savings in typical cases, and local renewable energy use could be increased by 10--80%. Allowing a fraction of high-priority tasks to proceed unimpeded still allows significant savings. Power grid operators use mechanisms called ancillary services to address variation and system failures, paying organizations to alter power consumption on request. By bidding to offer these services, data centres may be able to lower their energy costs while reducing their environmental impact. If providing contingency reserves which require only infrequent action, savings of up to 12% were seen in simulations. Greater power cost savings are possible for those ceding more control to the power grid operator. Coordinating multiple data centres adds overhead, and altering at which data centre requests are processed based on changes in the financial or environmental costs of power is likely to increase this overhead. Tests of virtual machine migrations showed that in some cases there was no visible increase in power use while in others power use rose by 20--30W. Estimates of how migration was likely to impact other services used in current cloud environments were derived.
Hadar, Eran; Mansur, Nariman; Ambar, Irit; Hod, Moshe
2011-06-01
Preterm delivery is a significant cause of neonatal morbidity and mortality. Pregnant women, with symptoms and signs consistent with preterm labor, can be treated with various tocolytic drugs. Atosiban is one of many drugs indicated to arrest imminent preterm labor. Various studies show that the efficacy of atosiban is similar to other tocolytic drugs. The main advantage of atosiban is a relativeLy low incidence of adverse maternal reactions. Its considerable shortcoming is the financial cost, compared to other available drugs. In view of its cost, we have decided to implement a strict protocol to direct the use of atosiban, with the intent to reduce costs, without hampering quality of care. The protocol was implemented from July 2009, and it outlines the medical and procedural terms to use atosiban. We compared similar time periods before and after implementation of the protocol. The outcomes compared included: treatment success, rates of preterm deliveries and financial costs. Within the timeframe that the protocol was implemented, we have been able to demonstrate a 40% reduction in atosiban related costs, compared to a parallel period, when the clinical guidelines were not implemented. This translates into savings of about NIS 40,000 (New Israeli Shekel) (approximately $10,000). This was achieved without an increase in the rate of preterm deliveries. Implementing and enforcing a simple protocol of supervision on the use of atosiban enables a considerable reduction of financial costs related to atosiban, without hampering medical care.
Flow cytometry for enrichment and titration in massively parallel DNA sequencing
Sandberg, Julia; Ståhl, Patrik L.; Ahmadian, Afshin; Bjursell, Magnus K.; Lundeberg, Joakim
2009-01-01
Massively parallel DNA sequencing is revolutionizing genomics research throughout the life sciences. However, the reagent costs and labor requirements in current sequencing protocols are still substantial, although improvements are continuously being made. Here, we demonstrate an effective alternative to existing sample titration protocols for the Roche/454 system using Fluorescence Activated Cell Sorting (FACS) technology to determine the optimal DNA-to-bead ratio prior to large-scale sequencing. Our method, which eliminates the need for the costly pilot sequencing of samples during titration is capable of rapidly providing accurate DNA-to-bead ratios that are not biased by the quantification and sedimentation steps included in current protocols. Moreover, we demonstrate that FACS sorting can be readily used to highly enrich fractions of beads carrying template DNA, with near total elimination of empty beads and no downstream sacrifice of DNA sequencing quality. Automated enrichment by FACS is a simple approach to obtain pure samples for bead-based sequencing systems, and offers an efficient, low-cost alternative to current enrichment protocols. PMID:19304748
Grizzle, R E; Ward, L G; Fredriksson, D W; Irish, J D; Langan, R; Heinig, C S; Greene, J K; Abeels, H A; Peter, C R; Eberhardt, A L
2014-11-15
The seafloor at an open ocean finfish aquaculture facility in the western Gulf of Maine, USA was monitored from 1999 to 2008 by sampling sites inside a predicted impact area modeled by oceanographic conditions and fecal and food settling characteristics, and nearby reference sites. Univariate and multivariate analyses of benthic community measures from box core samples indicated minimal or no significant differences between impact and reference areas. These findings resulted in development of an adaptive monitoring protocol involving initial low-cost methods that required more intensive and costly efforts only when negative impacts were initially indicated. The continued growth of marine aquaculture is dependent on further development of farming methods that minimize negative environmental impacts, as well as effective monitoring protocols. Adaptive monitoring protocols, such as the one described herein, coupled with mathematical modeling approaches, have the potential to provide effective protection of the environment while minimize monitoring effort and costs. Copyright © 2014 Elsevier Ltd. All rights reserved.
Seamless Insert-Plasmid Assembly at High Efficiency and Low Cost
Benoit, Roger M.; Ostermeier, Christian; Geiser, Martin; Li, Julia Su Zhou; Widmer, Hans; Auer, Manfred
2016-01-01
Seamless cloning methods, such as co-transformation cloning, sequence- and ligation-independent cloning (SLIC) or the Gibson assembly, are essential tools for the precise construction of plasmids. The efficiency of co-transformation cloning is however low and the Gibson assembly reagents are expensive. With the aim to improve the robustness of seamless cloning experiments while keeping costs low, we examined the importance of complementary single-stranded DNA ends for co-transformation cloning and the influence of single-stranded gaps in circular plasmids on SLIC cloning efficiency. Most importantly, our data show that single-stranded gaps in double-stranded plasmids, which occur in typical SLIC protocols, can drastically decrease the efficiency at which the DNA transforms competent E. coli bacteria. Accordingly, filling-in of single-stranded gaps using DNA polymerase resulted in increased transformation efficiency. Ligation of the remaining nicks did not lead to a further increase in transformation efficiency. These findings demonstrate that highly efficient insert-plasmid assembly can be achieved by using only T5 exonuclease and Phusion DNA polymerase, without Taq DNA ligase from the original Gibson protocol, which significantly reduces the cost of the reactions. We successfully used this modified Gibson assembly protocol with two short insert-plasmid overlap regions, each counting only 15 nucleotides. PMID:27073895
FuGeF: A Resource Bound Secure Forwarding Protocol for Wireless Sensor Networks.
Umar, Idris Abubakar; Mohd Hanapi, Zurina; Sali, A; Zulkarnain, Zuriati A
2016-06-22
Resource bound security solutions have facilitated the mitigation of spatio-temporal attacks by altering protocol semantics to provide minimal security while maintaining an acceptable level of performance. The Dynamic Window Secured Implicit Geographic Forwarding (DWSIGF) routing protocol for Wireless Sensor Network (WSN) has been proposed to achieve a minimal selection of malicious nodes by introducing a dynamic collection window period to the protocol's semantics. However, its selection scheme suffers substantial packet losses due to the utilization of a single distance based parameter for node selection. In this paper, we propose a Fuzzy-based Geographic Forwarding protocol (FuGeF) to minimize packet loss, while maintaining performance. The FuGeF utilizes a new form of dynamism and introduces three selection parameters: remaining energy, connectivity cost, and progressive distance, as well as a Fuzzy Logic System (FLS) for node selection. These introduced mechanisms ensure the appropriate selection of a non-malicious node. Extensive simulation experiments have been conducted to evaluate the performance of the proposed FuGeF protocol as compared to DWSIGF variants. The simulation results show that the proposed FuGeF outperforms the two DWSIGF variants (DWSIGF-P and DWSIGF-R) in terms of packet delivery.
A Fair Contention Access Scheme for Low-Priority Traffic in Wireless Body Area Networks
Sajeel, Muhammad; Bashir, Faisal; Asfand-e-yar, Muhammad; Tauqir, Muhammad
2017-01-01
Recently, wireless body area networks (WBANs) have attracted significant consideration in ubiquitous healthcare. A number of medium access control (MAC) protocols, primarily derived from the superframe structure of the IEEE 802.15.4, have been proposed in literature. These MAC protocols aim to provide quality of service (QoS) by prioritizing different traffic types in WBANs. A contention access period (CAP)with high contention in priority-based MAC protocols can result in higher number of collisions and retransmissions. During CAP, traffic classes with higher priority are dominant over low-priority traffic; this has led to starvation of low-priority traffic, thus adversely affecting WBAN throughput, delay, and energy consumption. Hence, this paper proposes a traffic-adaptive priority-based superframe structure that is able to reduce contention in the CAP period, and provides a fair chance for low-priority traffic. Simulation results in ns-3 demonstrate that the proposed MAC protocol, called traffic- adaptive priority-based MAC (TAP-MAC), achieves low energy consumption, high throughput, and low latency compared to the IEEE 802.15.4 standard, and the most recent priority-based MAC protocol, called priority-based MAC protocol (PA-MAC). PMID:28832495
Communication architecture system for fiber positioning of DESI spectrograph
NASA Astrophysics Data System (ADS)
Kaci, Karim; Glez-de-Rivera, Guillermo; Lopez-Colino, Fernando; Martinez-Garcia, M. Sofia; Masa, Jose L.; Garrido, Javier; Sanchez, Justo; Prada, Francisco
2016-07-01
This paper presents a design proposal for controlling the five thousand fiber positioners within the focal plate of the DESI instrument. Each of these positioners is a robot which allows positioning its optic fiber with a resolution within the range of few microns. The high number and density of these robots poses a challenge for handling the communication from a central control device to each of these five thousand. Furthermore, an additional restriction applies as the required time to communicate to every robot of its position must be smaller than a second. Additionally. a low energy consumption profile is also desired. Both wireless and wired communication protocols have been evaluated, proposing single-technology-based architectures and hybrid ones (a combination of them). Among the wireless solutions, ZigBee and CyFi have been considered. Using simulation tools these wireless protocols have been discarded as they do not allow an efficient communication. The studied wired protocols comprise I2C, CAN and Ethernet. The best solution found is a hybrid multilayer architecture combining both Ethernet and I2C. A 100 Mbps Ethernet based network is used to communicate the central control unit with ten management boards. Each of these boards is a low-cost, low-power embedded device that manages a thirty six degrees sector of the sensing plate. Each of these boards receives the positioning data for five hundred robots and communicate with each one through a fast mode plus I2C bus. This proposal allows to communicate the positioning information for all five thousand robots in 350 ms total.
Sources and Transportation of Bulk, Low-Cost Lunar Simulant Materials
NASA Technical Reports Server (NTRS)
Rickman, D. L.
2013-01-01
Marshall Space Flight Center (MSFC) has built the Lunar Surface Testbed using 200 tons of volcanic cinder and ash from the same source used for the simulant series JSC-1. This Technical Memorandum examines the alternatives examined for transportation and source. The cost of low-cost lunar simulant is driven by the cost of transportation, which is controlled by distance and, to a lesser extent, quantity. Metabasalts in the eastern United States were evaluated due to their proximity to MSFC. Volcanic cinder deposits in New Mexico, Colorado, and Arizona were recognized as preferred sources. In addition to having fewer green, secondary minerals, they contain vesicular glass, both of which are desirable. Transportation costs were more than 90% of the total procurement costs for the simulant material.
Herndon, Christopher N; Anaya, Yanett; Noel, Martha; Cakmak, Hakan; Cedars, Marcelle I
2017-10-01
To report on outcomes from a university-based low-cost and low-complexity IVF program using mild stimulation approaches and simplified protocols to provide basic access to ART to a socioculturally diverse low-income urban population. Retrospective cohort study. Academic infertility center. Sixty-five infertile couples were enrolled from a county hospital serving a low-resource largely immigrant population. Patients were nonrandomly allocated to one of four mild stimulation protocols: clomiphene/letrozole alone, two clomiphene/letrozole-based protocols involving sequential or flare addition of low-dose gonadotropins, and low-dose gonadotropins alone. Clinical fellows managed all aspects of cycle preparation, monitoring, oocyte retrieval, and embryo transfer under an attending preceptor. Retrieval was undertaken without administration of deep anesthesia, and laboratory interventions were minimized. All embryo transfers were performed at the cleavage stage. Sociomedical demographics, treatment response, and pregnancy outcomes were recorded. From August 2010 to June 2016, 65 patients initiated 161 stimulation IVF cycles, which resulted in 107 retrievals, 91 fresh embryo transfers, and 40 frozen embryo transfer cycles. The mean age of patients was 33.3 years, and mean reported duration of infertility was 5.3 years; 33.5% (54/161) of cycles were cancelled before oocyte retrieval, with 13% due to premature ovulation. Overall, cumulative live birth rates per retrieval including subsequent use of frozen embryos was 29.0%; 44.6% (29/65) of patients enrolled in the program achieved pregnancy. Use of mild stimulation protocols, simplified monitoring, and minimized laboratory handling procedures enabled access to care in a low-resource socioculturally diverse infertile population. Copyright © 2017. Published by Elsevier Inc.
Benson, K.; Estrada, T.; Taufer, M.; Lawrence, J.; Cochran, E.
2011-01-01
The Quake-Catcher Network (QCN) uses low-cost sensors connected to volunteer computers across the world to monitor seismic events. The location and density of these sensors' placement can impact the accuracy of the event detection. Because testing different special arrangements of new sensors could disrupt the currently active project, this would best be accomplished in a simulated environment. This paper presents an accurate and efficient framework for simulating the low cost QCN sensors and identifying their most effective locations and densities. Results presented show how our simulations are reliable tools to study diverse scenarios under different geographical and infrastructural constraints. ?? 2011 IEEE.
Musculoskeletal-induced Nucleation in Altitude Decompression Sickness
NASA Technical Reports Server (NTRS)
Pollock, N. W.; Natoli, M. J.; Conkin, J.; Wessel, J. H., III; Gernhardt, M. L.
2014-01-01
Musculoskeletal activity has the potential to both improve and compromise decompression safety. Exercise enhances inert gas elimination during oxygen breathing prior to decompression (prebreathe), but it may also promote bubble nuclei formation (nucleation), which can lead to gas phase separation and bubble growth and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity and the level of tissue supersaturation may be critical to the net effect. There are limited data available to evaluate cost-benefit relationships. Understanding the relationship is important to improve our understanding of the underlying mechanisms of nucleation in exercise prebreathe protocols and to quantify risk in gravity and microgravity environments. Data gathered during NASA's Prebreathe Reduction Program (PRP) studies combined oxygen prebreathe and exercise followed by low pressure (4.3 psi; altitude equivalent of 30,300 ft [9,235 m]) microgravity simulation to produce two protocols used by astronauts preparing for extravehicular activity. Both the Phase II/CEVIS (cycle ergometer vibration isolation system) and ISLE (in-suit light exercise) trials eliminated ambulation to more closely simulate the microgravity environment. The CEVIS results (35 male, 10 female) serve as control data for this NASA/Duke study to investigate the influence of ambulation exercise on bubble formation and the subsequent risk of DCS.
Williams, Cylie; Bowles, Kelly-Ann; Kiegaldie, Debra; Maloney, Stephen; Nestel, Debra; Kaplonyi, Jessica; Haines, Terry
2016-06-02
Simulation-based education (SBE) is now commonly used across health professional disciplines to teach a range of skills. The evidence base supporting the effectiveness of this approach for improving patient health outcomes is relatively narrow, focused mainly on the development of procedural skills. However, there are other simulation approaches used to support non-procedure specific skills that are in need of further investigation. This cluster, cross-over randomised controlled trial with a concurrent economic evaluation (cost per fall prevented) trial will evaluate the effectiveness, cost-effectiveness and student experience of health professional students undertaking simulation training for the prevention of falls among hospitalised inpatients. This research will target the students within the established undergraduate student placements of Monash University medicine, nursing and allied health across Peninsula Health acute and subacute inpatient wards. The intervention will train the students in how to provide the Safe Recovery program, the only single intervention approach demonstrated to reduce falls in hospitals. This will involve redevelopment of the Safe Recovery program into a one-to-many participant SBE program, so that groups of students learn the communication skills and falls prevention knowledge necessary for delivery of the program. The primary outcome of this research will be patient falls across participating inpatient wards, with secondary outcomes including student satisfaction with the SBE and knowledge gain, ward-level practice change and cost of acute/rehabilitation care for each patient measured using clinical costing data. The Human Research Ethics Committees of Peninsula Health (LRR/15/PH/11) and Monash University (CF15/3523-2015001384) have approved this research. The participant information and consent forms provide information on privacy, storage of results and dissemination. Registration of this trial has been completed with the Australian and New Zealand Clinical Trials Registry: ACTRN12615000817549. This study protocol has been prepared according to the Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT) checklist. ACTRN12615000817549; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Sensor Proxy Mobile IPv6 (SPMIPv6)—A Novel Scheme for Mobility Supported IP-WSNs
Islam, Md. Motaharul; Huh, Eui-Nam
2011-01-01
IP based Wireless Sensor Networks (IP-WSNs) are gaining importance for their broad range of applications in health-care, home automation, environmental monitoring, industrial control, vehicle telematics and agricultural monitoring. In all these applications, mobility in the sensor network with special attention to energy efficiency is a major issue to be addressed. Host-based mobility management protocols are not suitable for IP-WSNs because of their energy inefficiency, so network based mobility management protocols can be an alternative for the mobility supported IP-WSNs. In this paper we propose a network based mobility supported IP-WSN protocol called Sensor Proxy Mobile IPv6 (SPMIPv6). We present its architecture, message formats and also evaluate its performance considering signaling cost, mobility cost and energy consumption. Our analysis shows that with respect to the number of IP-WSN nodes, the proposed scheme reduces the signaling cost by 60% and 56%, as well as the mobility cost by 62% and 57%, compared to MIPv6 and PMIPv6, respectively. The simulation results also show that in terms of the number of hops, SPMIPv6 decreases the signaling cost by 56% and 53% as well as mobility cost by 60% and 67% as compared to MIPv6 and PMIPv6 respectively. It also indicates that proposed scheme reduces the level of energy consumption significantly. PMID:22319386
Sensor proxy mobile IPv6 (SPMIPv6)--a novel scheme for mobility supported IP-WSNs.
Islam, Md Motaharul; Huh, Eui-Nam
2011-01-01
IP based Wireless Sensor Networks (IP-WSNs) are gaining importance for their broad range of applications in health-care, home automation, environmental monitoring, industrial control, vehicle telematics and agricultural monitoring. In all these applications, mobility in the sensor network with special attention to energy efficiency is a major issue to be addressed. Host-based mobility management protocols are not suitable for IP-WSNs because of their energy inefficiency, so network based mobility management protocols can be an alternative for the mobility supported IP-WSNs. In this paper we propose a network based mobility supported IP-WSN protocol called Sensor Proxy Mobile IPv6 (SPMIPv6). We present its architecture, message formats and also evaluate its performance considering signaling cost, mobility cost and energy consumption. Our analysis shows that with respect to the number of IP-WSN nodes, the proposed scheme reduces the signaling cost by 60% and 56%, as well as the mobility cost by 62% and 57%, compared to MIPv6 and PMIPv6, respectively. The simulation results also show that in terms of the number of hops, SPMIPv6 decreases the signaling cost by 56% and 53% as well as mobility cost by 60% and 67% as compared to MIPv6 and PMIPv6 respectively. It also indicates that proposed scheme reduces the level of energy consumption significantly.
Performance bounds on parallel self-initiating discrete-event
NASA Technical Reports Server (NTRS)
Nicol, David M.
1990-01-01
The use is considered of massively parallel architectures to execute discrete-event simulations of what is termed self-initiating models. A logical process in a self-initiating model schedules its own state re-evaluation times, independently of any other logical process, and sends its new state to other logical processes following the re-evaluation. The interest is in the effects of that communication on synchronization. The performance is considered of various synchronization protocols by deriving upper and lower bounds on optimal performance, upper bounds on Time Warp's performance, and lower bounds on the performance of a new conservative protocol. The analysis of Time Warp includes the overhead costs of state-saving and rollback. The analysis points out sufficient conditions for the conservative protocol to outperform Time Warp. The analysis also quantifies the sensitivity of performance to message fan-out, lookahead ability, and the probability distributions underlying the simulation.
High-Throughput Screening Assay for Embryoid Body Differentiation of Human Embryonic Stem Cells
Outten, Joel T.; Gadue, Paul; French, Deborah L.; Diamond, Scott L.
2012-01-01
Serum-free human pluripotent stem cell media offer the potential to develop reproducible clinically applicable differentiation strategies and protocols. The vast array of possible growth factor and cytokine combinations for media formulations makes differentiation protocol optimization both labor and cost-intensive. This unit describes a 96-well plate, 4-color flow cytometry-based screening assay to optimize pluripotent stem cell differentiation protocols. We provide conditions both to differentiate human embryonic stem cells (hESCs) to the three primary germ layers, ectoderm, endoderm, and mesoderm, and to utilize flow cytometry to distinguish between them. This assay exhibits low inter-well variability and can be utilized to efficiently screen a variety of media formulations, reducing cost, incubator space, and labor. Protocols can be adapted to a variety of differentiation stages and lineages. PMID:22415836
Tang, Hongying; Cheng, Yongbo; Zhao, Qin; Li, Baoqing; Yuan, Xiaobing
2017-01-01
Routing protocols based on topology control are significantly important for improving network longevity in wireless sensor networks (WSNs). Traditionally, some WSN routing protocols distribute uneven network traffic load to sensor nodes, which is not optimal for improving network longevity. Differently to conventional WSN routing protocols, we propose a dynamic hierarchical protocol based on combinatorial optimization (DHCO) to balance energy consumption of sensor nodes and to improve WSN longevity. For each sensor node, the DHCO algorithm obtains the optimal route by establishing a feasible routing set instead of selecting the cluster head or the next hop node. The process of obtaining the optimal route can be formulated as a combinatorial optimization problem. Specifically, the DHCO algorithm is carried out by the following procedures. It employs a hierarchy-based connection mechanism to construct a hierarchical network structure in which each sensor node is assigned to a special hierarchical subset; it utilizes the combinatorial optimization theory to establish the feasible routing set for each sensor node, and takes advantage of the maximum–minimum criterion to obtain their optimal routes to the base station. Various results of simulation experiments show effectiveness and superiority of the DHCO algorithm in comparison with state-of-the-art WSN routing algorithms, including low-energy adaptive clustering hierarchy (LEACH), hybrid energy-efficient distributed clustering (HEED), genetic protocol-based self-organizing network clustering (GASONeC), and double cost function-based routing (DCFR) algorithms. PMID:28753962
Efficacy of new low-cost filtration device for recovering Schistosoma haematobium eggs from urine.
Gyorkos, T W; Ramsan, M; Foum, A; Khamis, I S
2001-07-01
A new, inexpensive filtration device for the diagnosis of urinary schistosomiasis was tested against the commonly used Millipore device. The experimental protocol was performed with 25 urine samples known to be positive for Schistosoma haematobium. The results suggest that the new device is as effective as the Millipore device for the diagnosis of urinary schistosomiasis. Its low cost will be attractive to schistosomiasis control programs.
Sun, Li; Westerdahl, Dane; Ning, Zhi
2017-08-19
Emerging low-cost gas sensor technologies have received increasing attention in recent years for air quality measurements due to their small size and convenient deployment. However, in the diverse applications these sensors face many technological challenges, including sensor drift over long-term deployment that cannot be easily addressed using mathematical correction algorithms or machine learning methods. This study aims to develop a novel approach to auto-correct the drift of commonly used electrochemical nitrogen dioxide (NO₂) sensor with comprehensive evaluation of its application. The impact of environmental factors on the NO₂ electrochemical sensor in low-ppb concentration level measurement was evaluated in laboratory and the temperature and relative humidity correction algorithm was evaluated. An automated zeroing protocol was developed and assessed using a chemical absorbent to remove NO₂ as a means to perform zero correction in varying ambient conditions. The sensor system was operated in three different environments in which data were compared to a reference NO₂ analyzer. The results showed that the zero-calibration protocol effectively corrected the observed drift of the sensor output. This technique offers the ability to enhance the performance of low-cost sensor based systems and these findings suggest extension of the approach to improve data quality from sensors measuring other gaseous pollutants in urban air.
Traffic Adaptive Energy Efficient and Low Latency Medium Access Control for Wireless Sensor Networks
NASA Astrophysics Data System (ADS)
Yadav, Rajesh; Varma, Shirshu; Malaviya, N.
2008-05-01
Medium access control for wireless sensor networks has been a very active research area in the recent years. The traditional wireless medium access control protocol such as IEEE 802.11 is not suitable for the sensor network application because these are battery powered. The recharging of these sensor nodes is expensive and also not possible. The most of the literature in the medium access for the sensor network focuses on the energy efficiency. The proposed MAC protocol solves the energy inefficiency caused by idle listening, control packet overhead and overhearing taking nodes latency into consideration based on the network traffic. Simulation experiments have been performed to demonstrate the effectiveness of the proposed approach. The validation of the simulation results of the proposed MAC has been done by comparing it with the analytical model. This protocol has been simulated in Network Simulator ns-2.
Conservative parallel simulation of priority class queueing networks
NASA Technical Reports Server (NTRS)
Nicol, David
1992-01-01
A conservative synchronization protocol is described for the parallel simulation of queueing networks having C job priority classes, where a job's class is fixed. This problem has long vexed designers of conservative synchronization protocols because of its seemingly poor ability to compute lookahead: the time of the next departure. For, a job in service having low priority can be preempted at any time by an arrival having higher priority and an arbitrarily small service time. The solution is to skew the event generation activity so that the events for higher priority jobs are generated farther ahead in simulated time than lower priority jobs. Thus, when a lower priority job enters service for the first time, all the higher priority jobs that may preempt it are already known and the job's departure time can be exactly predicted. Finally, the protocol was analyzed and it was demonstrated that good performance can be expected on the simulation of large queueing networks.
Conservative parallel simulation of priority class queueing networks
NASA Technical Reports Server (NTRS)
Nicol, David M.
1990-01-01
A conservative synchronization protocol is described for the parallel simulation of queueing networks having C job priority classes, where a job's class is fixed. This problem has long vexed designers of conservative synchronization protocols because of its seemingly poor ability to compute lookahead: the time of the next departure. For, a job in service having low priority can be preempted at any time by an arrival having higher priority and an arbitrarily small service time. The solution is to skew the event generation activity so that the events for higher priority jobs are generated farther ahead in simulated time than lower priority jobs. Thus, when a lower priority job enters service for the first time, all the higher priority jobs that may preempt it are already known and the job's departure time can be exactly predicted. Finally, the protocol was analyzed and it was demonstrated that good performance can be expected on the simulation of large queueing networks.
Low cost, high yield: simulation of obstetric emergencies for family medicine training.
Magee, Susanna R; Shields, Robin; Nothnagle, Melissa
2013-01-01
Simulation is now the educational standard for emergency training in residency and is particularly useful on a labor and delivery unit, which is often a stressful environment for learners given the frequency of emergencies. However, simulation can be costly. This study aimed to assess the feasibility and effectiveness of low-cost simulated obstetrical emergencies in training family medicine residents. The study took place in a community hospital in an urban underserved setting in the northeast United States. Low-cost simulations were developed for postpartum hemorrhage (PPH) and preeclampsia/eclampsia (PEC). Twenty residents were randomly assigned to the intervention (simulated PPH or PEC followed by debriefing) or control (lecture on PPH or PEC) group, and equal numbers of residents were assigned to each scenario. All participants completed a written test at baseline and an oral exam 6 months later on the respective scenario to which they were assigned. The participants provided written feedback on their respective teaching interventions. We compared performance on pretests and posttests by group using Wilcoxon Rank Sum. Twenty residents completed the study. Both groups performed similarly on baseline tests for both scenarios. Compared to controls, intervention residents scored significantly higher on the examination on the management of PPH but not for PEC. All intervention group participants reported that the simulation training was "extremely useful," and most found it "enjoyable." We demonstrated the feasibility and acceptability of two low-cost obstetric emergency simulations and found that they may result in persistent increases in trainee knowledge.
A routing protocol based on energy and link quality for Internet of Things applications.
Machado, Kássio; Rosário, Denis; Cerqueira, Eduardo; Loureiro, Antonio A F; Neto, Augusto; Souza, José Neuman de
2013-02-04
The Internet of Things (IoT) is attracting considerable attention from the universities, industries, citizens and governments for applications, such as healthcare, environmental monitoring and smart buildings. IoT enables network connectivity between smart devices at all times, everywhere, and about everything. In this context, Wireless Sensor Networks (WSNs) play an important role in increasing the ubiquity of networks with smart devices that are low-cost and easy to deploy. However, sensor nodes are restricted in terms of energy, processing and memory. Additionally, low-power radios are very sensitive to noise, interference and multipath distortions. In this context, this article proposes a routing protocol based on Routing by Energy and Link quality (REL) for IoT applications. To increase reliability and energy-efficiency, REL selects routes on the basis of a proposed end-to-end link quality estimator mechanism, residual energy and hop count. Furthermore, REL proposes an event-driven mechanism to provide load balancing and avoid the premature energy depletion of nodes/networks. Performance evaluations were carried out using simulation and testbed experiments to show the impact and benefits of REL in small and large-scale networks. The results show that REL increases the network lifetime and services availability, as well as the quality of service of IoT applications. It also provides an even distribution of scarce network resources and reduces the packet loss rate, compared with the performance of well-known protocols.
A Routing Protocol Based on Energy and Link Quality for Internet of Things Applications
Machado, Kassio; Rosário, Denis; Cerqueira, Eduardo; Loureiro, Antonio A. F.; Neto, Augusto; de Souza, José Neuman
2013-01-01
The Internet of Things (IoT) is attracting considerable attention from the universities, industries, citizens and governments for applications, such as healthcare,environmental monitoring and smart buildings. IoT enables network connectivity between smart devices at all times, everywhere, and about everything. In this context, Wireless Sensor Networks (WSNs) play an important role in increasing the ubiquity of networks with smart devices that are low-cost and easy to deploy. However, sensor nodes are restricted in terms of energy, processing and memory. Additionally, low-power radios are very sensitive to noise, interference and multipath distortions. In this context, this article proposes a routing protocol based on Routing by Energy and Link quality (REL) for IoT applications. To increase reliability and energy-efficiency, REL selects routes on the basis of a proposed end-to-end link quality estimator mechanism, residual energy and hop count. Furthermore, REL proposes an event-driven mechanism to provide load balancing and avoid the premature energy depletion of nodes/networks. Performance evaluations were carried out using simulation and testbed experiments to show the impact and benefits of REL in small and large-scale networks. The results show that REL increases the network lifetime and services availability, as well as the quality of service of IoT applications. It also provides an even distribution of scarce network resources and reduces the packet loss rate, compared with the performance of well-known protocols. PMID:23385410
FuGeF: A Resource Bound Secure Forwarding Protocol for Wireless Sensor Networks
Umar, Idris Abubakar; Mohd Hanapi, Zurina; Sali, A.; Zulkarnain, Zuriati A.
2016-01-01
Resource bound security solutions have facilitated the mitigation of spatio-temporal attacks by altering protocol semantics to provide minimal security while maintaining an acceptable level of performance. The Dynamic Window Secured Implicit Geographic Forwarding (DWSIGF) routing protocol for Wireless Sensor Network (WSN) has been proposed to achieve a minimal selection of malicious nodes by introducing a dynamic collection window period to the protocol’s semantics. However, its selection scheme suffers substantial packet losses due to the utilization of a single distance based parameter for node selection. In this paper, we propose a Fuzzy-based Geographic Forwarding protocol (FuGeF) to minimize packet loss, while maintaining performance. The FuGeF utilizes a new form of dynamism and introduces three selection parameters: remaining energy, connectivity cost, and progressive distance, as well as a Fuzzy Logic System (FLS) for node selection. These introduced mechanisms ensure the appropriate selection of a non-malicious node. Extensive simulation experiments have been conducted to evaluate the performance of the proposed FuGeF protocol as compared to DWSIGF variants. The simulation results show that the proposed FuGeF outperforms the two DWSIGF variants (DWSIGF-P and DWSIGF-R) in terms of packet delivery. PMID:27338411
Simple Automatic File Exchange (SAFE) to Support Low-Cost Spacecraft Operation via the Internet
NASA Technical Reports Server (NTRS)
Baker, Paul; Repaci, Max; Sames, David
1998-01-01
Various issues associated with Simple Automatic File Exchange (SAFE) are presented in viewgraph form. Specific topics include: 1) Packet telemetry, Internet IP networks and cost reduction; 2) Basic functions and technical features of SAFE; 3) Project goals, including low-cost satellite transmission to data centers to be distributed via an Internet; 4) Operations with a replicated file protocol; 5) File exchange operation; 6) Ground stations as gateways; 7) Lessons learned from demonstrations and tests with SAFE; and 8) Feedback and future initiatives.
Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi
2015-01-01
The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (p<0.001). During hospitalization, 298 accelerated diagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (p<0.001). Throughout the 90-day follow-up, diagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (p<0.001). Ultimately, most patients in both groups had non-invasive imaging testing. Accelerated diagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), p<0.01], and acute coronary syndromes [1 (0.3%) vs. 9 (3.2%), p<0.01], during the follow-up period. The accelerated diagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14-0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources.
Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi
2015-01-01
Aims The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Methods and Results Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (p<0.001). During hospitalization, 298 accelerated diagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (p<0.001). Throughout the 90-day follow-up, diagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (p<0.001). Ultimately, most patients in both groups had non-invasive imaging testing. Accelerated diagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), p<0.01], and acute coronary syndromes [1 (0.3%) vs. 9 (3.2%), p<0.01], during the follow-up period. The accelerated diagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14–0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. Conclusion An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources. PMID:25622029
NASA Astrophysics Data System (ADS)
Rui, Xue; Cheng, Lishui; Long, Yong; Fu, Lin; Alessio, Adam M.; Asma, Evren; Kinahan, Paul E.; De Man, Bruno
2015-09-01
For PET/CT systems, PET image reconstruction requires corresponding CT images for anatomical localization and attenuation correction. In the case of PET respiratory gating, multiple gated CT scans can offer phase-matched attenuation and motion correction, at the expense of increased radiation dose. We aim to minimize the dose of the CT scan, while preserving adequate image quality for the purpose of PET attenuation correction by introducing sparse view CT data acquisition. We investigated sparse view CT acquisition protocols resulting in ultra-low dose CT scans designed for PET attenuation correction. We analyzed the tradeoffs between the number of views and the integrated tube current per view for a given dose using CT and PET simulations of a 3D NCAT phantom with lesions inserted into liver and lung. We simulated seven CT acquisition protocols with {984, 328, 123, 41, 24, 12, 8} views per rotation at a gantry speed of 0.35 s. One standard dose and four ultra-low dose levels, namely, 0.35 mAs, 0.175 mAs, 0.0875 mAs, and 0.043 75 mAs, were investigated. Both the analytical Feldkamp, Davis and Kress (FDK) algorithm and the Model Based Iterative Reconstruction (MBIR) algorithm were used for CT image reconstruction. We also evaluated the impact of sinogram interpolation to estimate the missing projection measurements due to sparse view data acquisition. For MBIR, we used a penalized weighted least squares (PWLS) cost function with an approximate total-variation (TV) regularizing penalty function. We compared a tube pulsing mode and a continuous exposure mode for sparse view data acquisition. Global PET ensemble root-mean-squares-error (RMSE) and local ensemble lesion activity error were used as quantitative evaluation metrics for PET image quality. With sparse view sampling, it is possible to greatly reduce the CT scan dose when it is primarily used for PET attenuation correction with little or no measureable effect on the PET image. For the four ultra-low dose levels simulated, sparse view protocols with 41 and 24 views best balanced the tradeoff between electronic noise and aliasing artifacts. In terms of lesion activity error and ensemble RMSE of the PET images, these two protocols, when combined with MBIR, are able to provide results that are comparable to the baseline full dose CT scan. View interpolation significantly improves the performance of FDK reconstruction but was not necessary for MBIR. With the more technically feasible continuous exposure data acquisition, the CT images show an increase in azimuthal blur compared to tube pulsing. However, this blurring generally does not have a measureable impact on PET reconstructed images. Our simulations demonstrated that ultra-low-dose CT-based attenuation correction can be achieved at dose levels on the order of 0.044 mAs with little impact on PET image quality. Highly sparse 41- or 24- view ultra-low dose CT scans are feasible for PET attenuation correction, providing the best tradeoff between electronic noise and view aliasing artifacts. The continuous exposure acquisition mode could potentially be implemented in current commercially available scanners, thus enabling sparse view data acquisition without requiring x-ray tubes capable of operating in a pulsing mode.
Rui, Xue; Cheng, Lishui; Long, Yong; Fu, Lin; Alessio, Adam M.; Asma, Evren; Kinahan, Paul E.; De Man, Bruno
2015-01-01
For PET/CT systems, PET image reconstruction requires corresponding CT images for anatomical localization and attenuation correction. In the case of PET respiratory gating, multiple gated CT scans can offer phase-matched attenuation and motion correction, at the expense of increased radiation dose. We aim to minimize the dose of the CT scan, while preserving adequate image quality for the purpose of PET attenuation correction by introducing sparse view CT data acquisition. Methods We investigated sparse view CT acquisition protocols resulting in ultra-low dose CT scans designed for PET attenuation correction. We analyzed the tradeoffs between the number of views and the integrated tube current per view for a given dose using CT and PET simulations of a 3D NCAT phantom with lesions inserted into liver and lung. We simulated seven CT acquisition protocols with {984, 328, 123, 41, 24, 12, 8} views per rotation at a gantry speed of 0.35 seconds. One standard dose and four ultra-low dose levels, namely, 0.35 mAs, 0.175 mAs, 0.0875 mAs, and 0.04375 mAs, were investigated. Both the analytical FDK algorithm and the Model Based Iterative Reconstruction (MBIR) algorithm were used for CT image reconstruction. We also evaluated the impact of sinogram interpolation to estimate the missing projection measurements due to sparse view data acquisition. For MBIR, we used a penalized weighted least squares (PWLS) cost function with an approximate total-variation (TV) regularizing penalty function. We compared a tube pulsing mode and a continuous exposure mode for sparse view data acquisition. Global PET ensemble root-mean-squares-error (RMSE) and local ensemble lesion activity error were used as quantitative evaluation metrics for PET image quality. Results With sparse view sampling, it is possible to greatly reduce the CT scan dose when it is primarily used for PET attenuation correction with little or no measureable effect on the PET image. For the four ultra-low dose levels simulated, sparse view protocols with 41 and 24 views best balanced the tradeoff between electronic noise and aliasing artifacts. In terms of lesion activity error and ensemble RMSE of the PET images, these two protocols, when combined with MBIR, are able to provide results that are comparable to the baseline full dose CT scan. View interpolation significantly improves the performance of FDK reconstruction but was not necessary for MBIR. With the more technically feasible continuous exposure data acquisition, the CT images show an increase in azimuthal blur compared to tube pulsing. However, this blurring generally does not have a measureable impact on PET reconstructed images. Conclusions Our simulations demonstrated that ultra-low-dose CT-based attenuation correction can be achieved at dose levels on the order of 0.044 mAs with little impact on PET image quality. Highly sparse 41- or 24- view ultra-low dose CT scans are feasible for PET attenuation correction, providing the best tradeoff between electronic noise and view aliasing artifacts. The continuous exposure acquisition mode could potentially be implemented in current commercially available scanners, thus enabling sparse view data acquisition without requiring x-ray tubes capable of operating in a pulsing mode. PMID:26352168
A secure RFID authentication protocol adopting error correction code.
Chen, Chien-Ming; Chen, Shuai-Min; Zheng, Xinying; Chen, Pei-Yu; Sun, Hung-Min
2014-01-01
RFID technology has become popular in many applications; however, most of the RFID products lack security related functionality due to the hardware limitation of the low-cost RFID tags. In this paper, we propose a lightweight mutual authentication protocol adopting error correction code for RFID. Besides, we also propose an advanced version of our protocol to provide key updating. Based on the secrecy of shared keys, the reader and the tag can establish a mutual authenticity relationship. Further analysis of the protocol showed that it also satisfies integrity, forward secrecy, anonymity, and untraceability. Compared with other lightweight protocols, the proposed protocol provides stronger resistance to tracing attacks, compromising attacks and replay attacks. We also compare our protocol with previous works in terms of performance.
A Secure RFID Authentication Protocol Adopting Error Correction Code
Zheng, Xinying; Chen, Pei-Yu
2014-01-01
RFID technology has become popular in many applications; however, most of the RFID products lack security related functionality due to the hardware limitation of the low-cost RFID tags. In this paper, we propose a lightweight mutual authentication protocol adopting error correction code for RFID. Besides, we also propose an advanced version of our protocol to provide key updating. Based on the secrecy of shared keys, the reader and the tag can establish a mutual authenticity relationship. Further analysis of the protocol showed that it also satisfies integrity, forward secrecy, anonymity, and untraceability. Compared with other lightweight protocols, the proposed protocol provides stronger resistance to tracing attacks, compromising attacks and replay attacks. We also compare our protocol with previous works in terms of performance. PMID:24959619
Efficacy of New Low-Cost Filtration Device for Recovering Schistosoma haematobium Eggs from Urine
Gyorkos, Theresa W.; Ramsan, Mahdi; Foum, Ali; Khamis, Iddi Simba
2001-01-01
A new, inexpensive filtration device for the diagnosis of urinary schistosomiasis was tested against the commonly used Millipore device. The experimental protocol was performed with 25 urine samples known to be positive for Schistosoma haematobium. The results suggest that the new device is as effective as the Millipore device for the diagnosis of urinary schistosomiasis. Its low cost will be attractive to schistosomiasis control programs. PMID:11427595
Micarelli, Alessandro; Viziano, Andrea; Augimeri, Ivan; Micarelli, Domenico; Alessandrini, Marco
2017-12-01
Considering the emerging advantages related to virtual reality implementation in clinical rehabilitation, the aim of the present study was to discover possible (i) improvements achievable in unilateral vestibular hypofunction patients using a self-assessed head-mounted device (HMD)-based gaming procedure when combined with a classical vestibular rehabilitation protocol (HMD group) as compared with a group undergoing only vestibular rehabilitation and (ii) HMD procedure-related side effects. Therefore, 24 vestibular rehabilitation and 23-matched HMD unilateral vestibular hypofunction individuals simultaneously underwent a 4-week rehabilitation protocol. Both otoneurological measures (vestibulo-ocular reflex gain and postural arrangement by studying both posturography parameters and spectral values of body oscillation) and performance and self-report measures (Italian Dizziness Handicap Inventory; Activities-specific Balance Confidence scale; Zung Instrument for Anxiety Disorders, Dynamic Gait Index; and Simulator Sickness Questionnaire) were analyzed by means of a between-group/within-subject analysis of variance model. A significant post-treatment between-effect was found, and the HMD group demonstrated an overall improvement in vestibulo-ocular reflex gain on the lesional side, in posturography parameters, in low-frequency spectral domain, as well as in Italian Dizziness Handicap Inventory and Activities-specific Balance Confidence scale scores. Meanwhile, Simulator Sickness Questionnaire scores demonstrated a significant reduction in symptoms related to experimental home-based gaming tasks during the HMD procedure. Our findings revealed the possible advantages of HMD implementation in vestibular rehabilitation, suggesting it as an innovative, self-assessed, low-cost, and compliant tool useful in maximizing vestibular rehabilitation outcomes.
2013-03-01
series of checkpoints in a complex route network,” while observing standard traffic etiquette and regulations [17]. The rules for the 2012 RoboCup...structure or protocols above the PHY. To support AVEP operation, we developed a packet structure based on the transmission control protocol (TCP...Control Protocol .” 1981. [37] F. Ge, Q. Chen, Y. Wang, C. W. Bostian, T. W. Rondeau, and B. Le, “Cognitive radio: from spectrum sharing to adaptive
A PDA-based flexible telecommunication system for telemedicine applications.
Nazeran, Homer; Setty, Sunil; Haltiwanger, Emily; Gonzalez, Virgilio
2004-01-01
Technology has been used to deliver health care at a distance for many years. Telemedicine is a rapidly growing area and recently there are studies devoted to prehospital care of patients in emergency cases. In this work we have developed a compact, reliable, and low cost PDA-based telecommunication device for telemedicine applications to transmit audio, still images, and vital signs from a remote site to a fixed station such as a clinic or a hospital in real time. This was achieved based on a client-server architecture. A Pocket PC, a miniature camera, and a hands-free microphone were used at the client site and a desktop computer running the Windows XP operating system was used as a server. The server was located at a fixed station. The system was implemented on TCP/IP and HTTP protocol. Field tests have shown that the system can reliably transmit still images, audio, and sample vital signs from a simulated remote site to a fixed station either via a wired or wireless network in real time. The Pocket PC was used at the client site because of its compact size, low cost and processing capabilities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardy, A; Bostani, M; McMillan, K
Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generatedmore » using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.« less
Comparative Study on Various Authentication Protocols in Wireless Sensor Networks.
Rajeswari, S Raja; Seenivasagam, V
2016-01-01
Wireless sensor networks (WSNs) consist of lightweight devices with low cost, low power, and short-ranged wireless communication. The sensors can communicate with each other to form a network. In WSNs, broadcast transmission is widely used along with the maximum usage of wireless networks and their applications. Hence, it has become crucial to authenticate broadcast messages. Key management is also an active research topic in WSNs. Several key management schemes have been introduced, and their benefits are not recognized in a specific WSN application. Security services are vital for ensuring the integrity, authenticity, and confidentiality of the critical information. Therefore, the authentication mechanisms are required to support these security services and to be resilient to distinct attacks. Various authentication protocols such as key management protocols, lightweight authentication protocols, and broadcast authentication protocols are compared and analyzed for all secure transmission applications. The major goal of this survey is to compare and find out the appropriate protocol for further research. Moreover, the comparisons between various authentication techniques are also illustrated.
Comparative Study on Various Authentication Protocols in Wireless Sensor Networks
Rajeswari, S. Raja; Seenivasagam, V.
2016-01-01
Wireless sensor networks (WSNs) consist of lightweight devices with low cost, low power, and short-ranged wireless communication. The sensors can communicate with each other to form a network. In WSNs, broadcast transmission is widely used along with the maximum usage of wireless networks and their applications. Hence, it has become crucial to authenticate broadcast messages. Key management is also an active research topic in WSNs. Several key management schemes have been introduced, and their benefits are not recognized in a specific WSN application. Security services are vital for ensuring the integrity, authenticity, and confidentiality of the critical information. Therefore, the authentication mechanisms are required to support these security services and to be resilient to distinct attacks. Various authentication protocols such as key management protocols, lightweight authentication protocols, and broadcast authentication protocols are compared and analyzed for all secure transmission applications. The major goal of this survey is to compare and find out the appropriate protocol for further research. Moreover, the comparisons between various authentication techniques are also illustrated. PMID:26881272
Raspberry Pi-powered imaging for plant phenotyping.
Tovar, Jose C; Hoyer, J Steen; Lin, Andy; Tielking, Allison; Callen, Steven T; Elizabeth Castillo, S; Miller, Michael; Tessman, Monica; Fahlgren, Noah; Carrington, James C; Nusinow, Dmitri A; Gehan, Malia A
2018-03-01
Image-based phenomics is a powerful approach to capture and quantify plant diversity. However, commercial platforms that make consistent image acquisition easy are often cost-prohibitive. To make high-throughput phenotyping methods more accessible, low-cost microcomputers and cameras can be used to acquire plant image data. We used low-cost Raspberry Pi computers and cameras to manage and capture plant image data. Detailed here are three different applications of Raspberry Pi-controlled imaging platforms for seed and shoot imaging. Images obtained from each platform were suitable for extracting quantifiable plant traits (e.g., shape, area, height, color) en masse using open-source image processing software such as PlantCV. This protocol describes three low-cost platforms for image acquisition that are useful for quantifying plant diversity. When coupled with open-source image processing tools, these imaging platforms provide viable low-cost solutions for incorporating high-throughput phenomics into a wide range of research programs.
Low-Cost Simulation to Teach Anesthetists' Non-Technical Skills in Rwanda.
Skelton, Teresa; Nshimyumuremyi, Isaac; Mukwesi, Christian; Whynot, Sara; Zolpys, Lauren; Livingston, Patricia
2016-08-01
Safe anesthesia care is challenging in developing countries where there are shortages of personnel, drugs, equipment, and training. Anesthetists' Non-technical Skills (ANTS)-task management, team working, situation awareness, and decision making-are difficult to practice well in this context. Cesarean delivery is the most common surgical procedure in sub-Saharan Africa. This pilot study investigates whether a low-cost simulation model, with good psychological fidelity, can be used effectively to teach ANTS during cesarean delivery in Rwanda. Study participants were anesthesia providers working in a tertiary referral hospital in Rwanda. Baseline observations were conducted for 20 anesthesia providers during cesarean delivery using the established ANTS framework. After the first observation set was complete, participants were randomly assigned to either simulation intervention or control groups. The simulation intervention group underwent ANTS training using low-cost high psychological fidelity simulation with debriefing. No training was offered to the control group. Postintervention observations were then conducted in the same manner as the baseline observations. The primary outcome was the overall ANTS score (maximum, 16). The median (range) ANTS score of the simulation group was 13.5 (11-16). The ANTS score of the control group was 8 (8-9), with a statistically significant difference (P = .002). Simulation participants showed statistically significant improvement in subcategories and in the overall ANTS score compared with ANTS score before simulation exposure. Rwandan anesthesia providers show improvement in ANTS practice during cesarean delivery after 1 teaching session using a low-cost high psychological fidelity simulation model with debriefing.
NASA Technical Reports Server (NTRS)
Clare, Loren; Clement, B.; Gao, J.; Hutcherson, J.; Jennings, E.
2006-01-01
Described recent development of communications protocols, services, and associated tools targeted to reduce risk, reduce cost and increase efficiency of IND infrastructure and supported mission operations. Space-based networking technologies developed were: a) Provide differentiated quality of service (QoS) that will give precedence to traffic that users have selected as having the greatest importance and/or time-criticality; b) Improve the total value of information to users through the use of QoS prioritization techniques; c) Increase operational flexibility and improve command-response turnaround; d) Enable new class of networked and collaborative science missions; e) Simplify applications interfaces to communications services; and f) Reduce risk and cost from a common object model and automated scheduling and communications protocols. Technologies are described in three general areas: communications scheduling, middleware, and protocols. Additionally developed simulation environment, which provides comprehensive, quantitative understanding of the technologies performance within overall, evolving architecture, as well as ability to refine & optimize specific components.
Cost and Precision of Brownian Clocks
NASA Astrophysics Data System (ADS)
Barato, Andre C.; Seifert, Udo
2016-10-01
Brownian clocks are biomolecular networks that can count time. A paradigmatic example are proteins that go through a cycle, thus regulating some oscillatory behavior in a living system. Typically, such a cycle requires free energy often provided by ATP hydrolysis. We investigate the relation between the precision of such a clock and its thermodynamic costs. For clocks driven by a constant thermodynamic force, a given precision requires a minimal cost that diverges as the uncertainty of the clock vanishes. In marked contrast, we show that a clock driven by a periodic variation of an external protocol can achieve arbitrary precision at arbitrarily low cost. This result constitutes a fundamental difference between processes driven by a fixed thermodynamic force and those driven periodically. As a main technical tool, we map a periodically driven system with a deterministic protocol to one subject to an external protocol that changes in stochastic time intervals, which simplifies calculations significantly. In the nonequilibrium steady state of the resulting bipartite Markov process, the uncertainty of the clock can be deduced from the calculable dispersion of a corresponding current.
2016-09-01
2.3.2 Loss -of-Lubrication Protocol 5 2.3.3 Friction Mapping Protocol 7 2.4 Test Matrices 9 3. Results and Discussion 10 3.1 Load Capacity 10...protocols used to simulate relevant contact conditions are the load capacity (LC), loss -of-lubrication (LoL), and mapping protocols. 2.3.1 Load ...Entrainment velocity (m/s) Slip (%) Skew (°) Load (N) Contact stress (GPa) LoL 16 –100 0 100 1.29 2.3.2.2 Low-Speed Loss -of-Lubrication
Sun, Li; Westerdahl, Dane; Ning, Zhi
2017-01-01
Emerging low-cost gas sensor technologies have received increasing attention in recent years for air quality measurements due to their small size and convenient deployment. However, in the diverse applications these sensors face many technological challenges, including sensor drift over long-term deployment that cannot be easily addressed using mathematical correction algorithms or machine learning methods. This study aims to develop a novel approach to auto-correct the drift of commonly used electrochemical nitrogen dioxide (NO2) sensor with comprehensive evaluation of its application. The impact of environmental factors on the NO2 electrochemical sensor in low-ppb concentration level measurement was evaluated in laboratory and the temperature and relative humidity correction algorithm was evaluated. An automated zeroing protocol was developed and assessed using a chemical absorbent to remove NO2 as a means to perform zero correction in varying ambient conditions. The sensor system was operated in three different environments in which data were compared to a reference NO2 analyzer. The results showed that the zero-calibration protocol effectively corrected the observed drift of the sensor output. This technique offers the ability to enhance the performance of low-cost sensor based systems and these findings suggest extension of the approach to improve data quality from sensors measuring other gaseous pollutants in urban air. PMID:28825633
Internet-based videoconferencing and data collaboration for the imaging community.
Poon, David P; Langkals, John W; Giesel, Frederik L; Knopp, Michael V; von Tengg-Kobligk, Hendrik
2011-01-01
Internet protocol-based digital data collaboration with videoconferencing is not yet well utilized in the imaging community. Videoconferencing, combined with proven low-cost solutions, can provide reliable functionality and speed, which will improve rapid, time-saving, and cost-effective communications, within large multifacility institutions or globally with the unlimited reach of the Internet. The aim of this project was to demonstrate the implementation of a low-cost hardware and software setup that facilitates global data collaboration using WebEx and GoToMeeting Internet protocol-based videoconferencing software. Both products' features were tested and evaluated for feasibility across 2 different Internet networks, including a video quality and recording assessment. Cross-compatibility with an Apple OS is also noted in the evaluations. Departmental experiences with WebEx pertaining to clinical trials are also described. Real-time remote presentation of dynamic data was generally consistent across platforms. A reliable and inexpensive hardware and software setup for complete Internet-based data collaboration/videoconferencing can be achieved.
Yang, C Kevin; Alcantara, Sean; Goss, Selena; Lantis, John C
2015-04-01
Massive (≥100 cm(2)) venous leg ulcers (VLUs) demonstrate very low closure rates with standard compression therapy and are costly to manage. Negative-pressure wound therapy (NPWT), followed by a split-thickness skin graft (STSG), can be a cost-effective alternative to this standard care. We performed a cost analysis of these two treatments. A retrospective review was performed of 10 ulcers treated with surgical debridement, 7 days of inpatient NPWT with topical antiseptic instillation (NPWTi), and STSG, with 4 additional days of inpatient NPWT bolster over the graft. Independent medical cost estimators were used to compare the cost of this treatment protocol with standard outpatient compression therapy. The average length of time ulcers were present before patients entered the study was 38 months (range, 3-120 months). Eight of 10 patients had complete VLU closure by 6 months after NPWTi with STSG. The 6-month costs of the proposed treatment protocol and standard twice-weekly compression therapy were estimated to be $27,000 and $28,000, respectively. NPWTi with STSG treatment is more effective for closure of massive VLUs at 6 months than that reported for standard compression therapy. Further, the cost of the proposed treatment protocol is comparable with standard compression therapy. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Lemos, Laurinda; Alegria, Carlos; Oliveira, Joana; Machado, Ana; Oliveira, Pedro; Almeida, Armando
2011-01-01
In idiopathic trigeminal neuralgia (TN) the neuroimaging evaluation is usually normal, but in some cases a vascular compression of trigeminal nerve root is present. Although the latter condition may be referred to surgery, drug therapy is usually the first approach to control pain. This study compared the clinical outcome and direct costs of (1) a traditional treatment (carbamazepine [CBZ] in monotherapy [CBZ protocol]), (2) the association of gabapentin (GBP) and analgesic block of trigger-points with ropivacaine (ROP) (GBP+ROP protocol), and (3) a common TN surgery, microvascular decompression of the trigeminal nerve (MVD protocol). Sixty-two TN patients were randomly treated during 4 weeks (CBZ [n = 23] and GBP+ROP [n = 17] protocols) from cases of idiopathic TN, or selected for MVD surgery (n = 22) due to intractable pain. Direct medical cost estimates were determined by the price of drugs in 2008 and the hospital costs. Pain was evaluated using the Numerical Rating Scale (NRS) and number of pain crises; the Hospital Anxiety and Depression Scale, Sickness Impact Profile, and satisfaction with treatment and hospital team were evaluated. Assessments were performed at day 0 and 6 months after the beginning of treatment. All protocols showed a clinical improvement of pain control at month 6. The GBP+ROP protocol was the least expensive treatment, whereas surgery was the most expensive. With time, however, GBP+ROP tended to be the most and MVD the least expensive. No sequelae resulted in any patient after drug therapies, while after MDV surgery several patients showed important side effects. Data reinforce that, (1) TN patients should be carefully evaluated before choosing therapy for pain control, (2) different pharmacological approaches are available to initiate pain control at low costs, and (3) criteria for surgical interventions should be clearly defined due to important side effects, with the initial higher costs being strongly reduced with time. PMID:21941455
An Efficient Framework Model for Optimizing Routing Performance in VANETs.
Al-Kharasani, Nori M; Zulkarnain, Zuriati Ahmad; Subramaniam, Shamala; Hanapi, Zurina Mohd
2018-02-15
Routing in Vehicular Ad hoc Networks (VANET) is a bit complicated because of the nature of the high dynamic mobility. The efficiency of routing protocol is influenced by a number of factors such as network density, bandwidth constraints, traffic load, and mobility patterns resulting in frequency changes in network topology. Therefore, Quality of Service (QoS) is strongly needed to enhance the capability of the routing protocol and improve the overall network performance. In this paper, we introduce a statistical framework model to address the problem of optimizing routing configuration parameters in Vehicle-to-Vehicle (V2V) communication. Our framework solution is based on the utilization of the network resources to further reflect the current state of the network and to balance the trade-off between frequent changes in network topology and the QoS requirements. It consists of three stages: simulation network stage used to execute different urban scenarios, the function stage used as a competitive approach to aggregate the weighted cost of the factors in a single value, and optimization stage used to evaluate the communication cost and to obtain the optimal configuration based on the competitive cost. The simulation results show significant performance improvement in terms of the Packet Delivery Ratio (PDR), Normalized Routing Load (NRL), Packet loss (PL), and End-to-End Delay (E2ED).
ERIC Educational Resources Information Center
Rossi, Sergio; Benaglia, Maurizio; Brenna, Davide; Porta, Riccardo; Orlandi, Manuel
2015-01-01
A simple procedure to convert protein data bank files (.pdb) into a stereolithography file (.stl) using VMD software (Virtual Molecular Dynamic) is reported. This tutorial allows generating, with a very simple protocol, three-dimensional customized structures that can be printed by a low-cost 3D-printer, and used for teaching chemical education…
Mian, Adnan Noor; Fatima, Mehwish; Khan, Raees; Prakash, Ravi
2014-01-01
Energy efficiency is an important design paradigm in Wireless Sensor Networks (WSNs) and its consumption in dynamic environment is even more critical. Duty cycling of sensor nodes is used to address the energy consumption problem. However, along with advantages, duty cycle aware networks introduce some complexities like synchronization and latency. Due to their inherent characteristics, many traditional routing protocols show low performance in densely deployed WSNs with duty cycle awareness, when sensor nodes are supposed to have high mobility. In this paper we first present a three messages exchange Lightweight Random Walk Routing (LRWR) protocol and then evaluate its performance in WSNs for routing low data rate packets. Through NS-2 based simulations, we examine the LRWR protocol by comparing it with DYMO, a widely used WSN protocol, in both static and dynamic environments with varying duty cycles, assuming the standard IEEE 802.15.4 in lower layers. Results for the three metrics, that is, reliability, end-to-end delay, and energy consumption, show that LRWR protocol outperforms DYMO in scalability, mobility, and robustness, showing this protocol as a suitable choice in low duty cycle and dense WSNs.
Simulation platform of LEO satellite communication system based on OPNET
NASA Astrophysics Data System (ADS)
Zhang, Yu; Zhang, Yong; Li, Xiaozhuo; Wang, Chuqiao; Li, Haihao
2018-02-01
For the purpose of verifying communication protocol in the low earth orbit (LEO) satellite communication system, an Optimized Network Engineering Tool (OPNET) based simulation platform is built. Using the three-layer modeling mechanism, the network model, the node model and the process model of the satellite communication system are built respectively from top to bottom, and the protocol will be implemented by finite state machine and Proto-C language. According to satellite orbit parameters, orbit files are generated via Satellite Tool Kit (STK) and imported into OPNET, and the satellite nodes move along their orbits. The simulation platform adopts time-slot-driven mode, divides simulation time into continuous time slots, and allocates slot number for each time slot. A resource allocation strategy is simulated on this platform, and the simulation results such as resource utilization rate, system throughput and packet delay are analyzed, which indicate that this simulation platform has outstanding versatility.
NASA Astrophysics Data System (ADS)
Cui, Yank; Kobara, Kazukuni; Matsuura, Kanta; Imai, Hideki
As pervasive computing technologies develop fast, the privacy protection becomes a crucial issue and needs to be coped with very carefully. Typically, it is difficult to efficiently identify and manage plenty of the low-cost pervasive devices like Radio Frequency Identification Devices (RFID), without leaking any privacy information. In particular, the attacker may not only eavesdrop the communication in a passive way, but also mount an active attack to ask queries adaptively, which is obviously more dangerous. Towards settling this problem, in this paper, we propose two lightweight authentication protocols which are privacy-preserving against active attack, in an asymmetric way. That asymmetric style with privacy-oriented simplification succeeds to reduce the load of low-cost devices and drastically decrease the computation cost for the management of server. This is because that, unlike the usual management of the identities, our approach does not require any synchronization nor exhaustive search in the database, which enjoys great convenience in case of a large-scale system. The protocols are based on a fast asymmetric encryption with specialized simplification and only one cryptographic hash function, which consequently assigns an easy work to pervasive devices. Besides, our results do not require the strong assumption of the random oracle.
Internet Technology for Future Space Missions
NASA Technical Reports Server (NTRS)
Hennessy, Joseph F. (Technical Monitor); Rash, James; Casasanta, Ralph; Hogie, Keith
2002-01-01
Ongoing work at National Aeronautics and Space Administration Goddard Space Flight Center (NASA/GSFC), seeks to apply standard Internet applications and protocols to meet the technology challenge of future satellite missions. Internet protocols and technologies are under study as a future means to provide seamless dynamic communication among heterogeneous instruments, spacecraft, ground stations, constellations of spacecraft, and science investigators. The primary objective is to design and demonstrate in the laboratory the automated end-to-end transport of files in a simulated dynamic space environment using off-the-shelf, low-cost, commodity-level standard applications and protocols. The demonstrated functions and capabilities will become increasingly significant in the years to come as both earth and space science missions fly more sensors and the present labor-intensive, mission-specific techniques for processing and routing data become prohibitively. This paper describes how an IP-based communication architecture can support all existing operations concepts and how it will enable some new and complex communication and science concepts. The authors identify specific end-to-end data flows from the instruments to the control centers and scientists, and then describe how each data flow can be supported using standard Internet protocols and applications. The scenarios include normal data downlink and command uplink as well as recovery scenarios for both onboard and ground failures. The scenarios are based on an Earth orbiting spacecraft with downlink data rates from 300 Kbps to 4 Mbps. Included examples are based on designs currently being investigated for potential use by the Global Precipitation Measurement (GPM) mission.
Towards open-source, low-cost haptics for surgery simulation.
Suwelack, Stefan; Sander, Christian; Schill, Julian; Serf, Manuel; Danz, Marcel; Asfour, Tamim; Burger, Wolfgang; Dillmann, Rüdiger; Speidel, Stefanie
2014-01-01
In minimally invasive surgery (MIS), virtual reality (VR) training systems have become a promising education tool. However, the adoption of these systems in research and clinical settings is still limited by the high costs of dedicated haptics hardware for MIS. In this paper, we present ongoing research towards an open-source, low-cost haptic interface for MIS simulation. We demonstrate the basic mechanical design of the device, the sensor setup as well as its software integration.
Takakuwa, Kevin M; Halpern, Ethan J; Shofer, Frances S
2011-02-01
The study aimed to examine time and imaging costs of 2 different imaging strategies for low-risk emergency department (ED) observation patients with acute chest pain or symptoms suggestive of acute coronary syndrome. We compared a "triple rule-out" (TRO) 64-section multidetector computed tomography protocol with nuclear stress testing. This was a prospective observational cohort study of consecutive ED patients who were enrolled in our chest pain observation protocol during a 16-month period. Our standard observation protocol included a minimum of 2 sets of cardiac enzymes at least 6 hours apart followed by a nuclear stress test. Once a week, observation patients were offered a TRO (to evaluate for coronary artery disease, thoracic dissection, and pulmonary embolus) multidetector computed tomography with the option of further stress testing for those patients found to have evidence of coronary artery disease. We analyzed 832 consecutive observation patients including 214 patients who underwent the TRO protocol. Mean total length of stay was 16.1 hours for TRO patients, 16.3 hours for TRO plus other imaging test, 22.6 hours for nuclear stress testing, 23.3 hours for nuclear stress testing plus other imaging tests, and 23.7 hours for nuclear stress testing plus TRO (P < .0001 for TRO and TRO + other test compared to stress test ± other test). Mean imaging times were 3.6, 4.4, 5.9, 7.5, and 6.6 hours, respectively (P < .05 for TRO and TRO + other test compared to stress test ± other test). Mean imaging costs were $1307 for TRO patients vs $945 for nuclear stress testing. Triple rule-out reduced total length of stay and imaging time but incurred higher imaging costs. A per-hospital analysis would be needed to determine if patient time savings justify the higher imaging costs. Copyright © 2011 Elsevier Inc. All rights reserved.
Bridging FPGA and GPU technologies for AO real-time control
NASA Astrophysics Data System (ADS)
Perret, Denis; Lainé, Maxime; Bernard, Julien; Gratadour, Damien; Sevin, Arnaud
2016-07-01
Our team has developed a common environment for high performance simulations and real-time control of AO systems based on the use of Graphics Processors Units in the context of the COMPASS project. Such a solution, based on the ability of the real time core in the simulation to provide adequate computing performance, limits the cost of developing AO RTC systems and makes them more scalable. A code developed and validated in the context of the simulation may be injected directly into the system and tested on sky. Furthermore, the use of relatively low cost components also offers significant advantages for the system hardware platform. However, the use of GPUs in an AO loop comes with drawbacks: the traditional way of offloading computation from CPU to GPUs - involving multiple copies and unacceptable overhead in kernel launching - is not well suited in a real time context. This last application requires the implementation of a solution enabling direct memory access (DMA) to the GPU memory from a third party device, bypassing the operating system. This allows this device to communicate directly with the real-time core of the simulation feeding it with the WFS camera pixel stream. We show that DMA between a custom FPGA-based frame-grabber and a computation unit (GPU, FPGA, or Coprocessor such as Xeon-phi) across PCIe allows us to get latencies compatible with what will be needed on ELTs. As a fine-grained synchronization mechanism is not yet made available by GPU vendors, we propose the use of memory polling to avoid interrupts handling and involvement of a CPU. Network and Vision protocols are handled by the FPGA-based Network Interface Card (NIC). We present the results we obtained on a complete AO loop using camera and deformable mirror simulators.
Wang, Chenglong; Chen, Lin; Mu, Dali; Xin, Minqiang; Luan, Jie
2017-12-01
Endoscopic-assisted transaxillary dual-plane (EATD) technique is a popular procedure for breast augmentation, especially for Chinese women. However, frustration is often expressed by plastic surgeons when first attempting EATD surgery. Simulation-based teaching is beneficial for EATD training, but it is expensive. This study presents a low-cost simulator to help plastic surgeons exercise psychomotor skills during EATD surgery. The low-cost simulator was invented by Dr Jie Luan (the senior author) and made of some easily available materials including a mannequin, a T-shirt printed the bottom anatomical structure of the chest, the order of dissection, and the potential bleeding spot, and an elastic compression garment printed the upper anatomical structure and the cut-off position to sever the pectoralis major muscle. The first-year residents of plastic surgery assessed their improvement by completing a 5-item evaluation questionnaire at the beginning and at the end of the simulation. Fifty participants enrolled in this study. There was a significant difference (P < 0.05) before and after the training regarding candidate confidence, anatomical awareness, and endoscope control including the dexterity and hand-to-eye coordination. The low-cost and simple maintenance simulator may help plastic surgeons, especially those in developing countries, to improve gradually their EATD breast augmentation skills with no risks in a way. Further randomized controlled trials are needed to test its validity and reliability.
Point-to-Point Multicast Communications Protocol
NASA Technical Reports Server (NTRS)
Byrd, Gregory T.; Nakano, Russell; Delagi, Bruce A.
1987-01-01
This paper describes a protocol to support point-to-point interprocessor communications with multicast. Dynamic, cut-through routing with local flow control is used to provide a high-throughput, low-latency communications path between processors. In addition multicast transmissions are available, in which copies of a packet are sent to multiple destinations using common resources as much as possible. Special packet terminators and selective buffering are introduced to avoid a deadlock during multicasts. A simulated implementation of the protocol is also described.
Ferrández-Pastor, Francisco Javier; García-Chamizo, Juan Manuel; Nieto-Hidalgo, Mario; Mora-Pascual, Jerónimo; Mora-Martínez, José
2016-07-22
The application of Information Technologies into Precision Agriculture methods has clear benefits. Precision Agriculture optimises production efficiency, increases quality, minimises environmental impact and reduces the use of resources (energy, water); however, there are different barriers that have delayed its wide development. Some of these main barriers are expensive equipment, the difficulty to operate and maintain and the standard for sensor networks are still under development. Nowadays, new technological development in embedded devices (hardware and communication protocols), the evolution of Internet technologies (Internet of Things) and ubiquitous computing (Ubiquitous Sensor Networks) allow developing less expensive systems, easier to control, install and maintain, using standard protocols with low-power consumption. This work develops and test a low-cost sensor/actuator network platform, based in Internet of Things, integrating machine-to-machine and human-machine-interface protocols. Edge computing uses this multi-protocol approach to develop control processes on Precision Agriculture scenarios. A greenhouse with hydroponic crop production was developed and tested using Ubiquitous Sensor Network monitoring and edge control on Internet of Things paradigm. The experimental results showed that the Internet technologies and Smart Object Communication Patterns can be combined to encourage development of Precision Agriculture. They demonstrated added benefits (cost, energy, smart developing, acceptance by agricultural specialists) when a project is launched.
Ferrández-Pastor, Francisco Javier; García-Chamizo, Juan Manuel; Nieto-Hidalgo, Mario; Mora-Pascual, Jerónimo; Mora-Martínez, José
2016-01-01
The application of Information Technologies into Precision Agriculture methods has clear benefits. Precision Agriculture optimises production efficiency, increases quality, minimises environmental impact and reduces the use of resources (energy, water); however, there are different barriers that have delayed its wide development. Some of these main barriers are expensive equipment, the difficulty to operate and maintain and the standard for sensor networks are still under development. Nowadays, new technological development in embedded devices (hardware and communication protocols), the evolution of Internet technologies (Internet of Things) and ubiquitous computing (Ubiquitous Sensor Networks) allow developing less expensive systems, easier to control, install and maintain, using standard protocols with low-power consumption. This work develops and test a low-cost sensor/actuator network platform, based in Internet of Things, integrating machine-to-machine and human-machine-interface protocols. Edge computing uses this multi-protocol approach to develop control processes on Precision Agriculture scenarios. A greenhouse with hydroponic crop production was developed and tested using Ubiquitous Sensor Network monitoring and edge control on Internet of Things paradigm. The experimental results showed that the Internet technologies and Smart Object Communication Patterns can be combined to encourage development of Precision Agriculture. They demonstrated added benefits (cost, energy, smart developing, acceptance by agricultural specialists) when a project is launched. PMID:27455265
Olmstead, Craig; Cruz, Kyle; Stodilka, Robert; Zabel, Pamela; Wolfson, Robert
2015-02-01
Radionuclide therapies, including treatment of neuroendocrine tumors with lutetium-177 (Lu-177) octreotate, often involve hospital admission to minimize radiation exposure to the public. Overnight admission due to Lu-177 octreotate therapy incurs additional cost for the hospital and is an inconvenience for the patient. This study endeavors to characterize the potential radiation risk to caregivers and the public should Lu-177 octreotate therapies be performed on an outpatient basis. Dose rate measurements of radiation emanating from 10 patients were taken 30 min, 4, and 20 h after initiation of Lu-177 octreotate therapy. Instadose radiation dose measurement monitors were also placed around the patients' rooms to assess the potential cumulative radiation exposure during the initial 30 min-4 h after treatment (simulating the hospital-based component of the outpatient model) as well as 4-20 h after treatment (simulating the discharged outpatient portion). The mean recorded dose rate at 30 min, 4, and 20 h after therapy was 20.4, 14.0, and 6.6 μSv/h, respectively. The majority of the cumulative dose readings were below the minimum recordable threshold of 0.03 mSv, with a maximum dose recorded of 0.18 mSv. Given the low dose rate and cumulative levels of radiation measured, the results support that an outpatient Lu-177 octreotate treatment protocol would not jeopardize public safety. Nevertheless, the concept of ALARA still requires that detailed radiation safety protocols be developed for Lu-177 octreotate outpatients to minimize radiation exposure to family members, caregivers, and the general public.
A Decision-Tree Approach to Cost Comparison of Newborn Screening Strategies for Cystic Fibrosis
Wells, Janelle; Rosenberg, Marjorie; Hoffman, Gary; Anstead, Michael
2012-01-01
OBJECTIVE: Because cystic fibrosis can be difficult to diagnose and treat early, newborn screening programs have rapidly developed nationwide but methods vary widely. We therefore investigated the costs and consequences or specific outcomes of the 2 most commonly used methods. METHODS: With available data on screening and follow-up, we used a simulation approach with decision trees to compare immunoreactive trypsinogen (IRT) screening followed by a second IRT test against an IRT/DNA analysis. By using a Monte Carlo simulation program, variation in the model parameters for counts at various nodes of the decision trees, as well as for costs, are included and applied to fictional cohorts of 100 000 newborns. The outcome measures included the numbers of newborns given a diagnosis of cystic fibrosis and costs of screening strategy at each branch and cost per newborn. RESULTS: Simulations revealed a substantial number of potential missed diagnoses for the IRT/IRT system versus IRT/DNA. Although the IRT/IRT strategy with commonly used cutoff values offers an average overall cost savings of $2.30 per newborn, a breakdown of costs by societal segments demonstrated higher out-of-pocket costs for families. Two potential system failures causing delayed diagnoses were identified relating to the screening protocols and the follow-up system. CONCLUSIONS: The IRT/IRT screening algorithm reduces the costs to laboratories and insurance companies but has more system failures. IRT/DNA offers other advantages, including fewer delayed diagnoses and lower out-of-pocket costs to families. PMID:22291119
NASA Astrophysics Data System (ADS)
Zhang, Li; Jabbari, Faryar; Brown, Tim; Samuelsen, Scott
2014-12-01
Plug-in electric vehicles (PEVs) shift energy consumption from petroleum to electricity for the personal transportation sector. This work proposes a decentralized charging protocol for PEVs with grid operators updating the cost signal. Each PEV calculates its own optimal charging profile only once based on the cost signal, after it is plugged in, and sends the result back to the grid operators. Grid operators only need to aggregate charging profiles and update the load and cost. The existing PEV characteristics, national household travel survey (NHTS), California Independent System Operator (CAISO) demand, and estimates for future renewable generation in California are used to simulate PEV operation, PEV charging profiles, grid demand, and grid net load (demand minus renewable). Results show the proposed protocol has good performance for overnight net load valley filling if the costs to be minimized are proportional to the net load. Annual results are shown in terms of overnight load variation and comparisons are made with grid level valley filling results. Further, a target load can be approached in the same manner by using the gap between current load and the target load as the cost. The communication effort involved is quite modest.
The Use of Virtual Reality Computer Simulation in Learning Port-A Cath Injection
ERIC Educational Resources Information Center
Tsai, Sing-Ling; Chai, Sin-Kuo; Hsieh, Li-Feng; Lin, Shirling; Taur, Fang-Meei; Sung, Wen-Hsu; Doong, Ji-Liang
2008-01-01
Cost-benefit management trends in Taiwan healthcare settings have led nurses to perform more invasive skills, such as Port-A cath administration of medications. Accordingly, nurses must be well-prepared prior to teaching by the mentor and supervision method. The purpose of the current study was to develop a computer-assisted protocol using virtual…
de Oliveira, Marcus Vinicius Linhares; Santos, António Carvalho; Paulo, Graciano; Campos, Paulo Sergio Flores; Santos, Joana
2017-06-01
The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.
Simulation analysis of a microcomputer-based, low-cost Omega navigation system
NASA Technical Reports Server (NTRS)
Lilley, R. W.; Salter, R. J., Jr.
1976-01-01
The current status of research on a proposed micro-computer-based, low-cost Omega Navigation System (ONS) is described. The design approach emphasizes minimum hardware, maximum software, and the use of a low-cost, commercially-available microcomputer. Currently under investigation is the implementation of a low-cost navigation processor and its interface with an omega sensor to complete the hardware-based ONS. Sensor processor functions are simulated to determine how many of the sensor processor functions can be handled by innovative software. An input data base of live Omega ground and flight test data was created. The Omega sensor and microcomputer interface modules used to collect the data are functionally described. Automatic synchronization to the Omega transmission pattern is described as an example of the algorithms developed using this data base.
Fitzpatrick, Anne; Tumlinson, Katherine
2017-03-24
The use of simulated clients or "mystery clients" is a data collection approach in which a study team member presents at a health care facility or outlet pretending to be a real customer, patient, or client. Following the visit, the shopper records her observations. The use of mystery clients can overcome challenges of obtaining accurate measures of health care quality and improve the validity of quality assessments, particularly in low- and middle-income countries. However, mystery client studies should be carefully designed and monitored to avoid problems inherent to this data collection approach. In this article, we discuss our experiences with the mystery client methodology in studies conducted in public- and private-sector health facilities in Kenya and in private-sector facilities in Uganda. We identify both the benefits and the challenges in using this methodology to guide other researchers interested in using this technique. Recruitment of appropriate mystery clients who accurately represent the facility's clientele, have strong recall of recent events, and are comfortable in their role as undercover data collectors are key to successful implementation of this methodology. Additionally, developing detailed training protocols can help ensure mystery clients behave identically and mimic real patrons accurately while short checklists can help ensure mystery client responses are standardized. Strict confidentiality and protocols to avoid unnecessary exams or procedures should also be stressed during training and monitored carefully throughout the study. Despite these challenges, researchers should consider mystery client designs to measure actual provider behavior and to supplement self-reported provider behavior. Data from mystery client studies can provide critical insight into the quality of service provision unavailable from other data collection methods. The unique information available from the mystery client approach far outweighs the cost. © Fitzpatrick and Tumlinson.
Fitzpatrick, Anne; Tumlinson, Katherine
2017-01-01
ABSTRACT The use of simulated clients or “mystery clients” is a data collection approach in which a study team member presents at a health care facility or outlet pretending to be a real customer, patient, or client. Following the visit, the shopper records her observations. The use of mystery clients can overcome challenges of obtaining accurate measures of health care quality and improve the validity of quality assessments, particularly in low- and middle-income countries. However, mystery client studies should be carefully designed and monitored to avoid problems inherent to this data collection approach. In this article, we discuss our experiences with the mystery client methodology in studies conducted in public- and private-sector health facilities in Kenya and in private-sector facilities in Uganda. We identify both the benefits and the challenges in using this methodology to guide other researchers interested in using this technique. Recruitment of appropriate mystery clients who accurately represent the facility's clientele, have strong recall of recent events, and are comfortable in their role as undercover data collectors are key to successful implementation of this methodology. Additionally, developing detailed training protocols can help ensure mystery clients behave identically and mimic real patrons accurately while short checklists can help ensure mystery client responses are standardized. Strict confidentiality and protocols to avoid unnecessary exams or procedures should also be stressed during training and monitored carefully throughout the study. Despite these challenges, researchers should consider mystery client designs to measure actual provider behavior and to supplement self-reported provider behavior. Data from mystery client studies can provide critical insight into the quality of service provision unavailable from other data collection methods. The unique information available from the mystery client approach far outweighs the cost. PMID:28126970
Benchmark tests for a Formula SAE Student car prototyping
NASA Astrophysics Data System (ADS)
Mariasiu, Florin
2011-12-01
Aerodynamic characteristics of a vehicle are important elements in its design and construction. A low drag coefficient brings significant fuel savings and increased engine power efficiency. In designing and developing vehicles trough computer simulation process to determine the vehicles aerodynamic characteristics are using dedicated CFD (Computer Fluid Dynamics) software packages. However, the results obtained by this faster and cheaper method, are validated by experiments in wind tunnels tests, which are expensive and were complex testing equipment are used in relatively high costs. Therefore, the emergence and development of new low-cost testing methods to validate CFD simulation results would bring great economic benefits for auto vehicles prototyping process. This paper presents the initial development process of a Formula SAE Student race-car prototype using CFD simulation and also present a measurement system based on low-cost sensors through which CFD simulation results were experimentally validated. CFD software package used for simulation was Solid Works with the FloXpress add-on and experimental measurement system was built using four piezoresistive force sensors FlexiForce type.
Kaasalainen, Touko; Palmu, Kirsi; Lampinen, Anniina; Reijonen, Vappu; Leikola, Junnu; Kivisaari, Riku; Kortesniemi, Mika
2015-09-01
Medical professionals need to exercise particular caution when developing CT scanning protocols for children who require multiple CT studies, such as those with craniosynostosis. To evaluate the utility of ultra-low-dose CT protocols with model-based iterative reconstruction techniques for craniosynostosis imaging. We scanned two pediatric anthropomorphic phantoms with a 64-slice CT scanner using different low-dose protocols for craniosynostosis. We measured organ doses in the head region with metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters. Numerical simulations served to estimate organ and effective doses. We objectively and subjectively evaluated the quality of images produced by adaptive statistical iterative reconstruction (ASiR) 30%, ASiR 50% and Veo (all by GE Healthcare, Waukesha, WI). Image noise and contrast were determined for different tissues. Mean organ dose with the newborn phantom was decreased up to 83% compared to the routine protocol when using ultra-low-dose scanning settings. Similarly, for the 5-year phantom the greatest radiation dose reduction was 88%. The numerical simulations supported the findings with MOSFET measurements. The image quality remained adequate with Veo reconstruction, even at the lowest dose level. Craniosynostosis CT with model-based iterative reconstruction could be performed with a 20-μSv effective dose, corresponding to the radiation exposure of plain skull radiography, without compromising required image quality.
An Alternative Wearable Tracking System Based on a Low-Power Wide-Area Network.
Fernández-Garcia, Raul; Gil, Ignacio
2017-03-14
This work presents an alternative wearable tracking system based on a low-power wide area network. A complete GPS receiver was integrated with a textile substrate, and the latitude and longitude coordinates were sent to the cloud by means of the SIM-less SIGFOX network. To send the coordinates over SIGFOX protocol, a specific codification algorithm was used and a customized UHF antenna on jeans fabric was designed, simulated and tested. Moreover, to guarantee the compliance to international regulations for human body exposure to electromagnetic radiation, the electromagnetic specific absorption rate of this antenna was analyzed. A specific remote server was developed to decode the latitude and longitude coordinates. Once the coordinates have been decoded, the remote server sends this information to the open source data viewer SENTILO to show the location of the sensor node in a map. The functionality of this system has been demonstrated experimentally. The results guarantee the utility and wearability of the proposed tracking system for the development of sensor nodes and point out that it can be a low cost alternative to other commercial products based on GSM networks.
Simulation of a navigator algorithm for a low-cost GPS receiver
NASA Technical Reports Server (NTRS)
Hodge, W. F.
1980-01-01
The analytical structure of an existing navigator algorithm for a low cost global positioning system receiver is described in detail to facilitate its implementation on in-house digital computers and real-time simulators. The material presented includes a simulation of GPS pseudorange measurements, based on a two-body representation of the NAVSTAR spacecraft orbits, and a four component model of the receiver bias errors. A simpler test for loss of pseudorange measurements due to spacecraft shielding is also noted.
Drug waste minimization as an effective strategy of cost-containment in Oncology
2014-01-01
Background Sustainability of cancer care is a crucial issue for health care systems worldwide, even more during a time of economic recession. Low-cost measures are highly desirable to contain and reduce expenditures without impairing the quality of care. In this paper we aim to demonstrate the efficacy of drug waste minimization in reducing drug-related costs and its importance as a structural measure in health care management. Methods We first recorded intravenous cancer drugs prescription and amount of drug waste at the Oncology Department of Udine, Italy. Than we developed and applied a protocol for drug waste minimization based on per-pathology/per-drug scheduling of chemotherapies and pre-planned rounding of dosages. Results Before the protocol, drug wastage accounted for 8,3% of the Department annual drug expenditure. Over 70% of these costs were attributable to six drugs (cetuximab, docetaxel, gemcitabine, oxaliplatin, pemetrexed and trastuzumab) that we named ‘hot drugs’. Since the protocol introduction, we observed a 45% reduction in the drug waste expenditure. This benefit was confirmed in the following years and drug waste minimazion was able to limit the impact of new pricely drugs on the Department expenditures. Conclusions Facing current budgetary constraints, the application of a drug waste minimization model is effective in drug cost containment and may produce durable benefits. PMID:24507545
ZeroCal: Automatic MAC Protocol Calibration
NASA Astrophysics Data System (ADS)
Meier, Andreas; Woehrle, Matthias; Zimmerling, Marco; Thiele, Lothar
Sensor network MAC protocols are typically configured for an intended deployment scenario once and for all at compile time. This approach, however, leads to suboptimal performance if the network conditions deviate from the expectations. We present ZeroCal, a distributed algorithm that allows nodes to dynamically adapt to variations in traffic volume. Using ZeroCal, each node autonomously configures its MAC protocol at runtime, thereby trying to reduce the maximum energy consumption among all nodes. While the algorithm is readily usable for any asynchronous low-power listening or low-power probing protocol, we validate and demonstrate the effectiveness of ZeroCal on X-MAC. Extensive testbed experiments and simulations indicate that ZeroCal quickly adapts to traffic variations. We further show that ZeroCal extends network lifetime by 50% compared to an optimal configuration with identical and static MAC parameters at all nodes.
NASA Astrophysics Data System (ADS)
Balaguru, Uma Maheswari; Sundaresan, Lakshmikirupa; Manivannan, Jeganathan; Majunathan, Reji; Mani, Krishnapriya; Swaminathan, Akila; Venkatesan, Saravanakumar; Kasiviswanathan, Dharanibalan; Chatterjee, Suvro
2016-06-01
Disturbed fluid flow or modulated shear stress is associated with vascular conditions such as atherosclerosis, thrombosis, and aneurysm. In vitro simulation of the fluid flow around the plaque micro-environment remains a challenging approach. Currently available models have limitations such as complications in protocols, high cost, incompetence of co-culture and not being suitable for massive expression studies. Hence, the present study aimed to develop a simple, versatile model based on Computational Fluid Dynamics (CFD) simulation. Current observations of CFD have shown the regions of modulated shear stress by the disturbed fluid flow. To execute and validate the model in real sense, cell morphology, cytoskeletal arrangement, cell death, reactive oxygen species (ROS) profile, nitric oxide production and disturbed flow markers under the above condition were assessed. Endothelium at disturbed flow region which had been exposed to low shear stress and swirling flow pattern showed morphological and expression similarities with the pathological disturbed flow environment reported previously. Altogether, the proposed model can serve as a platform to simulate the real time micro-environment of disturbed flow associated with eccentric plaque shapes and the possibilities of studying its downstream events.
Kind, Amy J H; Brenny-Fitzpatrick, Maria; Leahy-Gross, Kris; Mirr, Jacquelyn; Chapman, Elizabeth; Frey, Brooke; Houlahan, Beth
2016-02-01
The Department of Veterans Affairs (VA) Coordinated-Transitional Care (C-TraC) program is a low-cost transitional care program that uses hospital-based nurse case managers, inpatient team integration, and in-depth posthospital telephone contacts to support high-risk patients and their caregivers as they transition from hospital to community. The low-cost, primarily telephone-based C-TraC program reduced 30-day rehospitalizations by one-third, leading to significant cost savings at one VA hospital. Non-VA hospitals have expressed interest in launching C-TraC, but non-VA hospitals differ in important ways from VA hospitals, particularly in terms of context, culture, and resources. The objective of this project was to adapt C-TraC to the specific context of one non-VA setting using a modified Replicating Effective Programs (REP) implementation theory model and to test the feasibility of this protocolized implementation approach. The modified REP model uses a mentored phased-based implementation with intensive preimplementation activities and harnesses key local stakeholders to adapt processes and goals to local context. Using this protocolized implementation approach, an adapted C-TraC protocol was created and launched at the non-VA hospital in July 2013. In its first 16 months, C-TraC successfully enrolled 1,247 individuals with 3.2 full-time nurse case managers, achieving good fidelity for core protocol steps. C-TraC participants experienced a 30-day rehospitalization rate of 10.8%, compared with 16.6% for a contemporary comparison group of similar individuals for whom C-TraC was not available (n = 1,307) (P < .001). The new C-TraC program continues in operation. Use of a modified REP model to guide protocolized adaptation to local context resulted in a C-TraC program that was feasible and sustained in a real-world non-VA setting. A modified REP implementation framework may be an appropriate foundational step for other clinical programs seeking to harness protocolized adaptation in mentored dissemination activities. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.
The Osseus platform: a prototype for advanced web-based distributed simulation
NASA Astrophysics Data System (ADS)
Franceschini, Derrick; Riecken, Mark
2016-05-01
Recent technological advances in web-based distributed computing and database technology have made possible a deeper and more transparent integration of some modeling and simulation applications. Despite these advances towards true integration of capabilities, disparate systems, architectures, and protocols will remain in the inventory for some time to come. These disparities present interoperability challenges for distributed modeling and simulation whether the application is training, experimentation, or analysis. Traditional approaches call for building gateways to bridge between disparate protocols and retaining interoperability specialists. Challenges in reconciling data models also persist. These challenges and their traditional mitigation approaches directly contribute to higher costs, schedule delays, and frustration for the end users. Osseus is a prototype software platform originally funded as a research project by the Defense Modeling & Simulation Coordination Office (DMSCO) to examine interoperability alternatives using modern, web-based technology and taking inspiration from the commercial sector. Osseus provides tools and services for nonexpert users to connect simulations, targeting the time and skillset needed to successfully connect disparate systems. The Osseus platform presents a web services interface to allow simulation applications to exchange data using modern techniques efficiently over Local or Wide Area Networks. Further, it provides Service Oriented Architecture capabilities such that finer granularity components such as individual models can contribute to simulation with minimal effort.
Self-Configuration and Self-Optimization Process in Heterogeneous Wireless Networks
Guardalben, Lucas; Villalba, Luis Javier García; Buiati, Fábio; Sobral, João Bosco Mangueira; Camponogara, Eduardo
2011-01-01
Self-organization in Wireless Mesh Networks (WMN) is an emergent research area, which is becoming important due to the increasing number of nodes in a network. Consequently, the manual configuration of nodes is either impossible or highly costly. So it is desirable for the nodes to be able to configure themselves. In this paper, we propose an alternative architecture for self-organization of WMN based on Optimized Link State Routing Protocol (OLSR) and the ad hoc on demand distance vector (AODV) routing protocols as well as using the technology of software agents. We argue that the proposed self-optimization and self-configuration modules increase the throughput of network, reduces delay transmission and network load, decreases the traffic of HELLO messages according to network’s scalability. By simulation analysis, we conclude that the self-optimization and self-configuration mechanisms can significantly improve the performance of OLSR and AODV protocols in comparison to the baseline protocols analyzed. PMID:22346584
Self-configuration and self-optimization process in heterogeneous wireless networks.
Guardalben, Lucas; Villalba, Luis Javier García; Buiati, Fábio; Sobral, João Bosco Mangueira; Camponogara, Eduardo
2011-01-01
Self-organization in Wireless Mesh Networks (WMN) is an emergent research area, which is becoming important due to the increasing number of nodes in a network. Consequently, the manual configuration of nodes is either impossible or highly costly. So it is desirable for the nodes to be able to configure themselves. In this paper, we propose an alternative architecture for self-organization of WMN based on Optimized Link State Routing Protocol (OLSR) and the ad hoc on demand distance vector (AODV) routing protocols as well as using the technology of software agents. We argue that the proposed self-optimization and self-configuration modules increase the throughput of network, reduces delay transmission and network load, decreases the traffic of HELLO messages according to network's scalability. By simulation analysis, we conclude that the self-optimization and self-configuration mechanisms can significantly improve the performance of OLSR and AODV protocols in comparison to the baseline protocols analyzed.
DTN routing in body sensor networks with dynamic postural partitioning.
Quwaider, Muhannad; Biswas, Subir
2010-11-01
This paper presents novel store-and-forward packet routing algorithms for Wireless Body Area Networks ( WBAN ) with frequent postural partitioning. A prototype WBAN has been constructed for experimentally characterizing on-body topology disconnections in the presence of ultra short range radio links, unpredictable RF attenuation, and human postural mobility. On-body DTN routing protocols are then developed using a stochastic link cost formulation, capturing multi-scale topological localities in human postural movements. Performance of the proposed protocols are evaluated experimentally and via simulation, and are compared with a number of existing single-copy DTN routing protocols and an on-body packet flooding mechanism that serves as a performance benchmark with delay lower-bound. It is shown that via multi-scale modeling of the spatio-temporal locality of on-body link disconnection patterns, the proposed algorithms can provide better routing performance compared to a number of existing probabilistic, opportunistic, and utility-based DTN routing protocols in the literature.
On Reliable and Efficient Data Gathering Based Routing in Underwater Wireless Sensor Networks.
Liaqat, Tayyaba; Akbar, Mariam; Javaid, Nadeem; Qasim, Umar; Khan, Zahoor Ali; Javaid, Qaisar; Alghamdi, Turki Ali; Niaz, Iftikhar Azim
2016-08-30
This paper presents cooperative routing scheme to improve data reliability. The proposed protocol achieves its objective, however, at the cost of surplus energy consumption. Thus sink mobility is introduced to minimize the energy consumption cost of nodes as it directly collects data from the network nodes at minimized communication distance. We also present delay and energy optimized versions of our proposed RE-AEDG to further enhance its performance. Simulation results prove the effectiveness of our proposed RE-AEDG in terms of the selected performance matrics.
An ultra-low-cost moving-base driving simulator
DOT National Transportation Integrated Search
2001-11-04
A novel approach to driving simulation is described, one that potentially overcomes the limitations of both motion fidelity and cost. It has become feasible only because of recent advances in computer-based image generation speed and fidelity and in ...
Low Cost Extraction and Isothermal Amplification of DNA for Infectious Diarrhea Diagnosis
Huang, Shichu; Do, Jaephil; Mahalanabis, Madhumita; Fan, Andy; Zhao, Lei; Jepeal, Lisa; Singh, Satish K.; Klapperich, Catherine M.
2013-01-01
In order to counter the common perception that molecular diagnostics are too complicated to work in low resource settings, we have performed a difficult sample preparation and DNA amplification protocol using instrumentation designed to be operated without wall or battery power. In this work we have combined a nearly electricity-free nucleic acid extraction process with an electricity-free isothermal amplification assay to detect the presence of Clostridium difficile (C. difficile) DNA in the stool of infected patients. We used helicase-dependent isothermal amplification (HDA) to amplify the DNA in a low-cost, thermoplastic reaction chip heated with a pair of commercially available toe warmers, while using a simple Styrofoam insulator. DNA was extracted from known positive and negative stool samples. The DNA extraction protocol utilized an air pressure driven solid phase extraction device run using a standard bicycle pump. The simple heater setup required no electricity or battery and was capable of maintaining the temperature at 65°C±2°C for 55 min, suitable for repeatable HDA amplification. Experiments were performed to explore the adaptability of the system for use in a range of ambient conditions. When compared to a traditional centrifuge extraction protocol and a laboratory thermocycler, this disposable, no power platform achieved approximately the same lower limit of detection (1.25×10−2 pg of C. difficile DNA) while requiring much less raw material and a fraction of the lab infrastructure and cost. This proof of concept study could greatly impact the accessibility of molecular assays for applications in global health. PMID:23555883
An Efficient Framework Model for Optimizing Routing Performance in VANETs
Zulkarnain, Zuriati Ahmad; Subramaniam, Shamala
2018-01-01
Routing in Vehicular Ad hoc Networks (VANET) is a bit complicated because of the nature of the high dynamic mobility. The efficiency of routing protocol is influenced by a number of factors such as network density, bandwidth constraints, traffic load, and mobility patterns resulting in frequency changes in network topology. Therefore, Quality of Service (QoS) is strongly needed to enhance the capability of the routing protocol and improve the overall network performance. In this paper, we introduce a statistical framework model to address the problem of optimizing routing configuration parameters in Vehicle-to-Vehicle (V2V) communication. Our framework solution is based on the utilization of the network resources to further reflect the current state of the network and to balance the trade-off between frequent changes in network topology and the QoS requirements. It consists of three stages: simulation network stage used to execute different urban scenarios, the function stage used as a competitive approach to aggregate the weighted cost of the factors in a single value, and optimization stage used to evaluate the communication cost and to obtain the optimal configuration based on the competitive cost. The simulation results show significant performance improvement in terms of the Packet Delivery Ratio (PDR), Normalized Routing Load (NRL), Packet loss (PL), and End-to-End Delay (E2ED). PMID:29462884
A MBD-seq protocol for large-scale methylome-wide studies with (very) low amounts of DNA.
Aberg, Karolina A; Chan, Robin F; Shabalin, Andrey A; Zhao, Min; Turecki, Gustavo; Staunstrup, Nicklas Heine; Starnawska, Anna; Mors, Ole; Xie, Lin Y; van den Oord, Edwin Jcg
2017-09-01
We recently showed that, after optimization, our methyl-CpG binding domain sequencing (MBD-seq) application approximates the methylome-wide coverage obtained with whole-genome bisulfite sequencing (WGB-seq), but at a cost that enables adequately powered large-scale association studies. A prior drawback of MBD-seq is the relatively large amount of genomic DNA (ideally >1 µg) required to obtain high-quality data. Biomaterials are typically expensive to collect, provide a finite amount of DNA, and may simply not yield sufficient starting material. The ability to use low amounts of DNA will increase the breadth and number of studies that can be conducted. Therefore, we further optimized the enrichment step. With this low starting material protocol, MBD-seq performed equally well, or better, than the protocol requiring ample starting material (>1 µg). Using only 15 ng of DNA as input, there is minimal loss in data quality, achieving 93% of the coverage of WGB-seq (with standard amounts of input DNA) at similar false/positive rates. Furthermore, across a large number of genomic features, the MBD-seq methylation profiles closely tracked those observed for WGB-seq with even slightly larger effect sizes. This suggests that MBD-seq provides similar information about the methylome and classifies methylation status somewhat more accurately. Performance decreases with <15 ng DNA as starting material but, even with as little as 5 ng, MBD-seq still achieves 90% of the coverage of WGB-seq with comparable genome-wide methylation profiles. Thus, the proposed protocol is an attractive option for adequately powered and cost-effective methylome-wide investigations using (very) low amounts of DNA.
How blockchain-timestamped protocols could improve the trustworthiness of medical science
Irving, Greg; Holden, John
2017-01-01
Trust in scientific research is diminished by evidence that data are being manipulated. Outcome switching, data dredging and selective publication are some of the problems that undermine the integrity of published research. Methods for using blockchain to provide proof of pre-specified endpoints in clinical trial protocols were first reported by Carlisle. We wished to empirically test such an approach using a clinical trial protocol where outcome switching has previously been reported. Here we confirm the use of blockchain as a low cost, independently verifiable method to audit and confirm the reliability of scientific studies. PMID:27239273
How blockchain-timestamped protocols could improve the trustworthiness of medical science.
Irving, Greg; Holden, John
2016-01-01
Trust in scientific research is diminished by evidence that data are being manipulated. Outcome switching, data dredging and selective publication are some of the problems that undermine the integrity of published research. Methods for using blockchain to provide proof of pre-specified endpoints in clinical trial protocols were first reported by Carlisle. We wished to empirically test such an approach using a clinical trial protocol where outcome switching has previously been reported. Here we confirm the use of blockchain as a low cost, independently verifiable method to audit and confirm the reliability of scientific studies.
Simulation Based Low-Cost Composite Process Development at the US Air Force Research Laboratory
NASA Technical Reports Server (NTRS)
Rice, Brian P.; Lee, C. William; Curliss, David B.
2003-01-01
Low-cost composite research in the US Air Force Research Laboratory, Materials and Manufacturing Directorate, Organic Matrix Composites Branch has focused on the theme of affordable performance. Practically, this means that we use a very broad view when considering the affordability of composites. Factors such as material costs, labor costs, recurring and nonrecurring manufacturing costs are balanced against performance to arrive at the relative affordability vs. performance measure of merit. The research efforts discussed here are two projects focused on affordable processing of composites. The first topic is the use of a neural network scheme to model cure reaction kinetics, then utilize the kinetics coupled with simple heat transport models to predict, in real-time, future exotherms and control them. The neural network scheme is demonstrated to be very robust and a much more efficient method that mechanistic cure modeling approach. This enables very practical low-cost processing of thick composite parts. The second project is liquid composite molding (LCM) process simulation. LCM processing of large 3D integrated composite parts has been demonstrated to be a very cost effective way to produce large integrated aerospace components specific examples of LCM processes are resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM), and other similar approaches. LCM process simulation is a critical part of developing an LCM process approach. Flow simulation enables the development of the most robust approach to introducing resin into complex preforms. Furthermore, LCM simulation can be used in conjunction with flow front sensors to control the LCM process in real-time to account for preform or resin variability.
ERIC Educational Resources Information Center
McNeal, McKenzie, III.
2012-01-01
Current networking architectures and communication protocols used for Wireless Sensor Networks (WSNs) have been designed to be energy efficient, low latency, and long network lifetime. One major issue that must be addressed is the security in data communication. Due to the limited capabilities of low cost and small sized sensor nodes, designing…
Low Duty-Cycling MAC Protocol for Low Data-Rate Medical Wireless Body Area Networks
Zhang, Chongqing; Wang, Yinglong; Liang, Yongquan; Shu, Minglei; Zhang, Jinquan; Ni, Lina
2017-01-01
Wireless body area networks (WBANs) are severely energy constrained, and how to improve the energy efficiency so as to prolong the network lifetime as long as possible is one of the most important goals of WBAN research. Low data-rate WBANs are promising to cut down the energy consumption and extend the network lifetime. Considering the characteristics and demands of low data-rate WBANs, a low duty-cycling medium access control (MAC) protocol is specially designed for this kind of WBAN in this paper. Longer superframes are exploited to cut down the energy consumed on the transmissions and receptions of redundant beacon frames. Insertion time slots are embedded into the inactive part of a superframe to deliver the frames and satisfy the quality of service (QoS) requirements. The number of the data subsections in an insertion time slot can be adaptively adjusted so as to accommodate low data-rate WBANs with different traffic. Simulation results show that the proposed MAC protocol performs well under the condition of low data-rate monitoring traffic. PMID:28509849
Blanchet, Karl; Lewis, James J; Pozo-Martin, Francisco; Satouro, Arsene; Somda, Serge; Ilboudo, Patrick; Sarrassat, Sophie; Cousens, Simon
2016-08-04
Burkina Faso introduced the Integrated Management of Childhood Illnesses (IMCI) strategy in 2003. However, an evaluation conducted in 2013 found that only 28 % of children were assessed for three danger signs as recommended by IMCI, and only 15 % of children were correctly classified. About 30 % of children were correctly prescribed with an antibiotic for suspected pneumonia or oral rehydration salts (ORS) for diarrhoea, and 40 % were correctly referred. Recent advances in information and communication technologies (ICT) and use of electronic clinical protocols hold the potential to transform healthcare delivery in low-income countries. However, no evidence is available on the effect of ICT on adherence to IMCI. This paper describes the research protocol of a mixed methods study that aims to measure the effect of the Integrated electronic Diagnosis Approach innovation (an electronic IMCI protocol provided to nurses) in two regions of Burkina Faso. The study combines a stepped-wedge trial, a realistic evaluation and an economic study in order to capture the effect of the innovation after its introduction on the level of adherence, cost and acceptability. The main challenge is to interconnect the three substudies. In integrating outcome, process and cost data, we focus on three key questions: (i) How does the effectiveness and the cost of the intervention vary by type of health worker and type of health centre? (ii) What is the impact of changes in the content, coverage and quality of the IeDA intervention on adherence and cost-effectiveness? (iii) What mechanisms of change (including costs) might explain the relationship between the IeDA intervention and adherence? Clinicaltrials.gov, NCT02341469 .
Ullah, Sana; Kwak, Kyung Sup
2012-06-01
Wireless Body Area Network (WBAN) consists of low-power, miniaturized, and autonomous wireless sensor nodes that enable physicians to remotely monitor vital signs of patients and provide real-time feedback with medical diagnosis and consultations. It is the most reliable and cheaper way to take care of patients suffering from chronic diseases such as asthma, diabetes and cardiovascular diseases. Some of the most important attributes of WBAN is low-power consumption and delay. This can be achieved by introducing flexible duty cycling techniques on the energy constraint sensor nodes. Stated otherwise, low duty cycle nodes should not receive frequent synchronization and control packets if they have no data to send/receive. In this paper, we introduce a Traffic-adaptive MAC protocol (TaMAC) by taking into account the traffic information of the sensor nodes. The protocol dynamically adjusts the duty cycle of the sensor nodes according to their traffic-patterns, thus solving the idle listening and overhearing problems. The traffic-patterns of all sensor nodes are organized and maintained by the coordinator. The TaMAC protocol is supported by a wakeup radio that is used to accommodate emergency and on-demand events in a reliable manner. The wakeup radio uses a separate control channel along with the data channel and therefore it has considerably low power consumption requirements. Analytical expressions are derived to analyze and compare the performance of the TaMAC protocol with the well-known beacon-enabled IEEE 802.15.4 MAC, WiseMAC, and SMAC protocols. The analytical derivations are further validated by simulation results. It is shown that the TaMAC protocol outperforms all other protocols in terms of power consumption and delay.
Angus, Simon D.; Piotrowska, Monika Joanna
2014-01-01
Multi-dose radiotherapy protocols (fraction dose and timing) currently used in the clinic are the product of human selection based on habit, received wisdom, physician experience and intra-day patient timetabling. However, due to combinatorial considerations, the potential treatment protocol space for a given total dose or treatment length is enormous, even for relatively coarse search; well beyond the capacity of traditional in-vitro methods. In constrast, high fidelity numerical simulation of tumor development is well suited to the challenge. Building on our previous single-dose numerical simulation model of EMT6/Ro spheroids, a multi-dose irradiation response module is added and calibrated to the effective dose arising from 18 independent multi-dose treatment programs available in the experimental literature. With the developed model a constrained, non-linear, search for better performing cadidate protocols is conducted within the vicinity of two benchmarks by genetic algorithm (GA) techniques. After evaluating less than 0.01% of the potential benchmark protocol space, candidate protocols were identified by the GA which conferred an average of 9.4% (max benefit 16.5%) and 7.1% (13.3%) improvement (reduction) on tumour cell count compared to the two benchmarks, respectively. Noticing that a convergent phenomenon of the top performing protocols was their temporal synchronicity, a further series of numerical experiments was conducted with periodic time-gap protocols (10 h to 23 h), leading to the discovery that the performance of the GA search candidates could be replicated by 17–18 h periodic candidates. Further dynamic irradiation-response cell-phase analysis revealed that such periodicity cohered with latent EMT6/Ro cell-phase temporal patterning. Taken together, this study provides powerful evidence towards the hypothesis that even simple inter-fraction timing variations for a given fractional dose program may present a facile, and highly cost-effecitive means of significantly improving clinical efficacy. PMID:25460164
Angus, Simon D; Piotrowska, Monika Joanna
2014-01-01
Multi-dose radiotherapy protocols (fraction dose and timing) currently used in the clinic are the product of human selection based on habit, received wisdom, physician experience and intra-day patient timetabling. However, due to combinatorial considerations, the potential treatment protocol space for a given total dose or treatment length is enormous, even for relatively coarse search; well beyond the capacity of traditional in-vitro methods. In constrast, high fidelity numerical simulation of tumor development is well suited to the challenge. Building on our previous single-dose numerical simulation model of EMT6/Ro spheroids, a multi-dose irradiation response module is added and calibrated to the effective dose arising from 18 independent multi-dose treatment programs available in the experimental literature. With the developed model a constrained, non-linear, search for better performing cadidate protocols is conducted within the vicinity of two benchmarks by genetic algorithm (GA) techniques. After evaluating less than 0.01% of the potential benchmark protocol space, candidate protocols were identified by the GA which conferred an average of 9.4% (max benefit 16.5%) and 7.1% (13.3%) improvement (reduction) on tumour cell count compared to the two benchmarks, respectively. Noticing that a convergent phenomenon of the top performing protocols was their temporal synchronicity, a further series of numerical experiments was conducted with periodic time-gap protocols (10 h to 23 h), leading to the discovery that the performance of the GA search candidates could be replicated by 17-18 h periodic candidates. Further dynamic irradiation-response cell-phase analysis revealed that such periodicity cohered with latent EMT6/Ro cell-phase temporal patterning. Taken together, this study provides powerful evidence towards the hypothesis that even simple inter-fraction timing variations for a given fractional dose program may present a facile, and highly cost-effecitive means of significantly improving clinical efficacy.
Keller, Benjamin A; Salcedo, Edgardo S; Williams, Timothy K; Neff, Lucas P; Carden, Anthony J; Li, Yiran; Gotlib, Oren; Tran, Nam K; Galante, Joseph M
2016-09-01
Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an adjunct technique for salvaging patients with noncompressible torso hemorrhage. Current REBOA training paradigms require large animals, virtual reality simulators, or human cadavers for acquisition of skills. These training strategies are expensive and resource intensive, which may prevent widespread dissemination of REBOA. We have developed a low-cost, near-physiologic, pulsatile REBOA simulator by connecting an anatomic vascular circuit constructed out of latex and polyvinyl chloride tubing to a commercially available pump. This pulsatile simulator is capable of generating cardiac outputs ranging from 1.7 to 6.8 L/min with corresponding arterial blood pressures of 54 to 226/14 to 121 mmHg. The simulator accommodates a 12 French introducer sheath and a CODA balloon catheter. Upon balloon inflation, the arterial waveform distal to the occlusion flattens, distal pulsation within the simulator is lost, and systolic blood pressures proximal to the balloon catheter increase by up to 62 mmHg. Further development and validation of this simulator will allow for refinement, reduction, and replacement of large animal models, costly virtual reality simulators, and perfused cadavers for training purposes. This will ultimately facilitate the low-cost, high-fidelity REBOA simulation needed for the widespread dissemination of this life-saving technique.
An Enhanced Reservation-Based MAC Protocol for IEEE 802.15.4 Networks
Afonso, José A.; Silva, Helder D.; Macedo, Pedro; Rocha, Luis A.
2011-01-01
The IEEE 802.15.4 Medium Access Control (MAC) protocol is an enabling standard for wireless sensor networks. In order to support applications requiring dedicated bandwidth or bounded delay, it provides a reservation-based scheme named Guaranteed Time Slot (GTS). However, the GTS scheme presents some drawbacks, such as inefficient bandwidth utilization and support to a maximum of only seven devices. This paper presents eLPRT (enhanced Low Power Real Time), a new reservation-based MAC protocol that introduces several performance enhancing features in comparison to the GTS scheme. This MAC protocol builds on top of LPRT (Low Power Real Time) and includes various mechanisms designed to increase data transmission reliability against channel errors, improve bandwidth utilization and increase the number of supported devices. A motion capture system based on inertial and magnetic sensors has been used to validate the protocol. The effectiveness of the performance enhancements introduced by each of the new features is demonstrated through the provision of both simulation and experimental results. PMID:22163826
The costs and cost-effectiveness of an integrated sepsis treatment protocol.
Talmor, Daniel; Greenberg, Dan; Howell, Michael D; Lisbon, Alan; Novack, Victor; Shapiro, Nathan
2008-04-01
Sepsis is associated with high mortality and treatment costs. International guidelines recommend the implementation of integrated sepsis protocols; however, the true cost and cost-effectiveness of these are unknown. To assess the cost-effectiveness of an integrated sepsis protocol, as compared with conventional care. Prospective cohort study of consecutive patients presenting with septic shock and enrolled in the institution's integrated sepsis protocol. Clinical and economic outcomes were compared with a historical control cohort. Beth Israel Deaconess Medical Center. Overall, 79 patients presenting to the emergency department with septic shock in the treatment cohort and 51 patients in the control group. An integrated sepsis treatment protocol incorporating empirical antibiotics, early goal-directed therapy, intensive insulin therapy, lung-protective ventilation, and consideration for drotrecogin alfa and steroid therapy. In-hospital treatment costs were collected using the hospital's detailed accounting system. The cost-effectiveness analysis was performed from the perspective of the healthcare system using a lifetime horizon. The primary end point for the cost-effectiveness analysis was the incremental cost per quality-adjusted life year gained. Mortality in the treatment group was 20.3% vs. 29.4% in the control group (p = .23). Implementing an integrated sepsis protocol resulted in a mean increase in cost of approximately $8,800 per patient, largely driven by increased intensive care unit length of stay. Life expectancy and quality-adjusted life years were higher in the treatment group; 0.78 and 0.54, respectively. The protocol was associated with an incremental cost of $11,274 per life-year saved and a cost of $16,309 per quality-adjusted life year gained. In patients with septic shock, an integrated sepsis protocol, although not cost-saving, appears to be cost-effective and compares very favorably to other commonly delivered acute care interventions.
Short-Term Monitoring Results for Advanced New Construction Test House -- Roseville, California
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stecher, D.; Brozyna, K.; Imm, C.
2013-09-01
A builder (K. Hovnanian Homes), design consultant, and trades collaborated to identify a systems integrated measures package for a 2,253-ft2 slab-on-grade ranch house to achieve a modeled energy savings of 60% with respect to the Building America House Simulation Protocols (Hendron, R. and Engebrecht, C. 'Building America House Simulation Protocols.' Golden, CO: National Renewable EnergyLaboratory, 2010) while minimizing construction costs and without requiring changes to the drawing that would impact local code or zoning approval. The key building improvements were applying R-10 insulation to the slab edge, increasing exterior wall cavity insulation from R-13 to R-15, and increasing attic insulationmore » from R-30 to R-38. Also, the air handling unit was relocated from the attic toconditioned space, and ductwork was relocated along the attic floor with an insulated bulkhead built above it. Short-term testing results showed that duct air leakage was low due to short duct runs and the placement of ductwork in conditioned space. However, during commissioning, the lack of access for servicing the ductwork and dampers in the bulkhead area prevented retroactive balancing ofindividual branches, resulting in significant differences between specified and measured airflow values for some duct runs. Thermal imaging results performed on the house when operating in both heating and cooling modes validated historic stratification issues of ceiling supply registers with high supply air temperatures. Long-term monitoring results will be detailed in a future report.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-10-01
A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory.). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the communitymore » scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.« less
Low Thrust Orbital Maneuvers Using Ion Propulsion
NASA Astrophysics Data System (ADS)
Ramesh, Eric
2011-10-01
Low-thrust maneuver options, such as electric propulsion, offer specific challenges within mission-level Modeling, Simulation, and Analysis (MS&A) tools. This project seeks to transition techniques for simulating low-thrust maneuvers from detailed engineering level simulations such as AGI's Satellite ToolKit (STK) Astrogator to mission level simulations such as the System Effectiveness Analysis Simulation (SEAS). Our project goals are as follows: A) Assess different low-thrust options to achieve various orbital changes; B) Compare such approaches to more conventional, high-thrust profiles; C) Compare computational cost and accuracy of various approaches to calculate and simulate low-thrust maneuvers; D) Recommend methods for implementing low-thrust maneuvers in high-level mission simulations; E) prototype recommended solutions.
Zanella, Fabian; Sheikh, Farah
2016-01-01
The generation of human induced pluripotent stem cell (hiPSC)-derived cardiomyocytes has been of utmost interest for the study of cardiac development, cardiac disease modeling, and evaluation of cardiotoxic effects of novel candidate drugs. Several protocols have been developed to guide human stem cells toward the cardiogenic path. Pioneering work used serum to promote cardiogenesis; however, low cardiogenic throughputs, lack of chemical definition, and batch-to-batch variability of serum lots constituted a considerable impediment to the implementation of those protocols to large-scale cell biology. Further work focused on the manipulation of pathways that mouse genetics indicated to be fundamental in cardiac development to promote cardiac differentiation in stem cells. Although extremely elegant, those serum-free protocols involved the use of human recombinant cytokines that tend to be quite costly and which can also be variable between lots. The latest generation of cardiogenic protocols aimed for a more cost-effective and reproducible definition of the conditions driving cardiac differentiation, using small molecules to manipulate cardiogenic pathways overriding the need for cytokines. This chapter details methods based on currently available cardiac differentiation protocols for the generation and characterization of robust numbers of hiPSC-derived cardiomyocytes under chemically defined conditions.
A Novel Cross-Layer Routing Protocol Based on Network Coding for Underwater Sensor Networks.
Wang, Hao; Wang, Shilian; Bu, Renfei; Zhang, Eryang
2017-08-08
Underwater wireless sensor networks (UWSNs) have attracted increasing attention in recent years because of their numerous applications in ocean monitoring, resource discovery and tactical surveillance. However, the design of reliable and efficient transmission and routing protocols is a challenge due to the low acoustic propagation speed and complex channel environment in UWSNs. In this paper, we propose a novel cross-layer routing protocol based on network coding (NCRP) for UWSNs, which utilizes network coding and cross-layer design to greedily forward data packets to sink nodes efficiently. The proposed NCRP takes full advantages of multicast transmission and decode packets jointly with encoded packets received from multiple potential nodes in the entire network. The transmission power is optimized in our design to extend the life cycle of the network. Moreover, we design a real-time routing maintenance protocol to update the route when detecting inefficient relay nodes. Substantial simulations in underwater environment by Network Simulator 3 (NS-3) show that NCRP significantly improves the network performance in terms of energy consumption, end-to-end delay and packet delivery ratio compared with other routing protocols for UWSNs.
Down, P M; Bradley, A J; Breen, J E; Green, M J
2017-09-15
The objective of this study was to use probabilistic sensitivity analysis to evaluate the cost-effectiveness of using an on-farm culture (OFC) approach to the treatment of clinical mastitis in dairy cows and compare this to a 'standard' treatment approach. A specific aim was to identify the herd circumstances under which an OFC approach would be most likely to be cost-effective. A stochastic Monte Carlo model was developed to simulate 5000 cases of clinical mastitis at the cow level and to calculate the associated costs simultaneously when treated according to 2 different treatment protocols; i) a 'conventional' approach (3 tubes of intramammary antibiotic) and ii) an OFC programme, whereby cows are treated according to the results of OFC. Model parameters were taken from recent peer reviewed literature on the use of OFC prior to treatment of clinical mastitis. Spearman rank correlation coefficients were used to evaluate the relationships between model input values and the estimated difference in cost between the standard and OFC treatment protocols. The simulation analyses revealed that both the difference in the bacteriological cure rate due to a delay in treatment when using OFC and the proportion of Gram-positive cases that occur on a dairy unit would have a fundamental impact on whether OFC would be cost-effective. The results of this study illustrated that an OFC approach for the treatment of clinical mastitis would probably not be cost-effective in many circumstances, in particular, not those in which Gram-positive pathogens were responsible for more than 20% of all clinical cases. The results highlight an ethical dilemma surrounding reduced use of antimicrobials for clinical mastitis since it may be associated with financial losses and poorer cow welfare in many instances. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Kemp, Chandler E; Ravikumar, Arvind P; Brandt, Adam R
2016-04-19
We present a tool for modeling the performance of methane leak detection and repair programs that can be used to evaluate the effectiveness of detection technologies and proposed mitigation policies. The tool uses a two-state Markov model to simulate the evolution of methane leakage from an artificial natural gas field. Leaks are created stochastically, drawing from the current understanding of the frequency and size distributions at production facilities. Various leak detection and repair programs can be simulated to determine the rate at which each would identify and repair leaks. Integrating the methane leakage over time enables a meaningful comparison between technologies, using both economic and environmental metrics. We simulate four existing or proposed detection technologies: flame ionization detection, manual infrared camera, automated infrared drone, and distributed detectors. Comparing these four technologies, we found that over 80% of simulated leakage could be mitigated with a positive net present value, although the maximum benefit is realized by selectively targeting larger leaks. Our results show that low-cost leak detection programs can rely on high-cost technology, as long as it is applied in a way that allows for rapid detection of large leaks. Any strategy to reduce leakage should require a careful consideration of the differences between low-cost technologies and low-cost programs.
Simulation at the point of care: reduced-cost, in situ training via a mobile cart.
Weinstock, Peter H; Kappus, Liana J; Garden, Alexander; Burns, Jeffrey P
2009-03-01
The rapid growth of simulation in health care has challenged traditional paradigms of hospital-based education and training. Simulation addresses patient safety through deliberative practice of high-risk low-frequency events within a safe, structured environment. Despite its inherent appeal, widespread adoption of simulation is prohibited by high cost, limited space, interruptions to clinical duties, and the inability to replicate important nuances of clinical environments. We therefore sought to develop a reduced-cost low-space mobile cart to provide realistic simulation experiences to a range of providers within the clinical environment and to serve as a model for transportable, cost-effective, widespread simulation-based training of bona-fide workplace teams. Descriptive study. A tertiary care pediatric teaching hospital. A self-contained mobile simulation cart was constructed at a cost of $8054 (mannequin not included). The cart is compatible with any mannequin and contains all equipment needed to produce a high quality simulation experience equivalent to that of our on-site center--including didactics and debriefing with videotaped recordings complete with vital sign overlay. Over a 3-year period the cart delivered 57 courses to 425 participants from five pediatric departments. All individuals were trained among their native teams and within their own clinical environment. By bringing all pedagogical elements to the actual clinical environment, a mobile cart can provide simulation to hospital teams that might not otherwise benefit from the educational tool. By reducing the setup cost and the need for dedicated space, the mobile approach provides a mechanism to increase the number of institutions capable of harnessing the power of simulation-based education internationally.
Ultra Low Power Signal Oriented Approach for Wireless Health Monitoring
Marinkovic, Stevan; Popovici, Emanuel
2012-01-01
In recent years there is growing pressure on the medical sector to reduce costs while maintaining or even improving the quality of care. A potential solution to this problem is real time and/or remote patient monitoring by using mobile devices. To achieve this, medical sensors with wireless communication, computational and energy harvesting capabilities are networked on, or in, the human body forming what is commonly called a Wireless Body Area Network (WBAN). We present the implementation of a novel Wake Up Receiver (WUR) in the context of standardised wireless protocols, in a signal-oriented WBAN environment and present a novel protocol intended for wireless health monitoring (WhMAC). WhMAC is a TDMA-based protocol with very low power consumption. It utilises WBAN-specific features and a novel ultra low power wake up receiver technology, to achieve flexible and at the same time very low power wireless data transfer of physiological signals. As the main application is in the medical domain, or personal health monitoring, the protocol caters for different types of medical sensors. We define four sensor modes, in which the sensors can transmit data, depending on the sensor type and emergency level. A full power dissipation model is provided for the protocol, with individual hardware and application parameters. Finally, an example application shows the reduction in the power consumption for different data monitoring scenarios. PMID:22969379
Ultra low power signal oriented approach for wireless health monitoring.
Marinkovic, Stevan; Popovici, Emanuel
2012-01-01
In recent years there is growing pressure on the medical sector to reduce costs while maintaining or even improving the quality of care. A potential solution to this problem is real time and/or remote patient monitoring by using mobile devices. To achieve this, medical sensors with wireless communication, computational and energy harvesting capabilities are networked on, or in, the human body forming what is commonly called a Wireless Body Area Network (WBAN). We present the implementation of a novel Wake Up Receiver (WUR) in the context of standardised wireless protocols, in a signal-oriented WBAN environment and present a novel protocol intended for wireless health monitoring (WhMAC). WhMAC is a TDMA-based protocol with very low power consumption. It utilises WBAN-specific features and a novel ultra low power wake up receiver technology, to achieve flexible and at the same time very low power wireless data transfer of physiological signals. As the main application is in the medical domain, or personal health monitoring, the protocol caters for different types of medical sensors. We define four sensor modes, in which the sensors can transmit data, depending on the sensor type and emergency level. A full power dissipation model is provided for the protocol, with individual hardware and application parameters. Finally, an example application shows the reduction in the power consumption for different data monitoring scenarios.
Multiplex Droplet Digital PCR Protocols for Quantification of GM Maize Events.
Dobnik, David; Spilsberg, Bjørn; Bogožalec Košir, Alexandra; Štebih, Dejan; Morisset, Dany; Holst-Jensen, Arne; Žel, Jana
2018-01-01
The standard-curve based simplex quantitative polymerase chain reaction (qPCR) has been the gold standard for DNA target quantification for more than a decade. The large and growing number of individual analyses needed to test for genetically modified organisms (GMOs) is reducing the cost-effectiveness of qPCR. Droplet digital PCR (ddPCR) enables absolute quantification without standard curves, avoids the amplification efficiency bias observed with qPCR, allows more accurate estimations at low target copy numbers and, in combination with multiplexing, significantly improves cost efficiency. Here we describe two protocols for multiplex quantification of GM maize events: (1) nondiscriminating, with multiplex quantification of targets as a group (12 GM maize lines) and (2) discriminating, with multiplex quantification of individual targets (events). The first enables the quantification of twelve European Union authorized GM maize events as a group with only two assays, but does not permit determination of the individual events present. The second protocol enables the quantification of four individual targets (three GM events and one endogene) in a single reaction. Both protocols can be modified for quantification of any other DNA target.
Efficacy of Low-Cost PC-Based Aviation Training Devices
ERIC Educational Resources Information Center
Reweti, Savern; Gilbey, Andrew; Jeffrey, Lynn
2017-01-01
Aim/Purpose: The aim of this study was to explore whether a full cost flight training device (FTD) was significantly better for simulator training than a low cost PC-Based Aviation Training Device (PCATD). Background: A quasi-transfer study was undertaken to ascertain whether a Civil Aviation Authority certified Flight Training Device (FTD) was…
Rate of transmission: a major determinant of the cost of clinical mastitis.
Down, P M; Green, M J; Hudson, C D
2013-10-01
The aim of this research was to use probabilistic sensitivity analysis to evaluate the relative importance of different components of a model designed to estimate the cost of clinical mastitis (CM). A particular focus was placed on the importance of pathogen transmission relative to other factors, such as milk price or treatment costs. A stochastic Monte Carlo model was developed to simulate a case of CM at the cow level and to calculate the associated costs for 5 defined treatment protocols. The 5 treatment protocols modeled were 3 d of antibiotic intramammary treatment, 5 d of antibiotic intramammary treatment, 3 d of intramammary and systemic antibiotic treatment, 3d of intramammary and systemic antibiotic treatment plus 1 d of nonsteroidal antiinflammatory drug treatment, and 5 d of intramammary and systemic antibiotic treatment. Uniform distributions were used throughout the model to enable investigation of the cost of CM over a spectrum of clinically realistic scenarios without specifying which scenario was more or less likely. A risk of transmission parameter distribution, based on literature values, was included to model the effect of pathogen transmission to uninfected cows, from cows that remained subclinically infected after treatment for CM. Spearman rank correlation coefficients were used to evaluate the relationships between model input values and the estimated cost of CM. Linear regression models were used to explore the effect that changes to specific independent variables had on the cost of CM. Risk of transmission was found to have the strongest association with the cost of CM, followed by bacteriological cure rate, cost of culling, and yield loss. Other factors such as milk price, cost of labor, and cost of medicines were of minimal influence in comparison. The cost of CM was similar for all 5 treatment protocols. The results from this study suggest that, when seeking to minimize the economic impact of CM in dairy herds, great emphasis should be placed on the reduction of pathogen transmission from cows with CM to uninfected cows. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Enhancing Time Synchronization Support in Wireless Sensor Networks
Tavares Bruscato, Leandro; Heimfarth, Tales; Pignaton de Freitas, Edison
2017-01-01
With the emerging Internet of Things (IoT) technology becoming reality, a number of applications are being proposed. Several of these applications are highly dependent on wireless sensor networks (WSN) to acquire data from the surrounding environment. In order to be really useful for most of applications, the acquired data must be coherent in terms of the time in which they are acquired, which implies that the entire sensor network presents a certain level of time synchronization. Moreover, to efficiently exchange and forward data, many communication protocols used in WSN rely also on time synchronization among the sensor nodes. Observing the importance in complying with this need for time synchronization, this work focuses on the second synchronization problem, proposing, implementing and testing a time synchronization service for low-power WSN using low frequency real-time clocks in each node. To implement this service, three algorithms based on different strategies are proposed: one based on an auto-correction approach, the second based on a prediction mechanism, while the third uses an analytical correction mechanism. Their goal is the same, i.e., to make the clocks of the sensor nodes converge as quickly as possible and then to keep them most similar as possible. This goal comes along with the requirement to keep low energy consumption. Differently from other works in the literature, the proposal here is independent of any specific protocol, i.e., it may be adapted to be used in different protocols. Moreover, it explores the minimum number of synchronization messages by means of a smart clock update strategy, allowing the trade-off between the desired level of synchronization and the associated energy consumption. Experimental results, which includes data acquired from simulations and testbed deployments, provide evidence of the success in meeting this goal, as well as providing means to compare these three approaches considering the best synchronization results and their costs in terms of energy consumption. PMID:29261113
Enhancing Time Synchronization Support in Wireless Sensor Networks.
Tavares Bruscato, Leandro; Heimfarth, Tales; Pignaton de Freitas, Edison
2017-12-20
With the emerging Internet of Things (IoT) technology becoming reality, a number of applications are being proposed. Several of these applications are highly dependent on wireless sensor networks (WSN) to acquire data from the surrounding environment. In order to be really useful for most of applications, the acquired data must be coherent in terms of the time in which they are acquired, which implies that the entire sensor network presents a certain level of time synchronization. Moreover, to efficiently exchange and forward data, many communication protocols used in WSN rely also on time synchronization among the sensor nodes. Observing the importance in complying with this need for time synchronization, this work focuses on the second synchronization problem, proposing, implementing and testing a time synchronization service for low-power WSN using low frequency real-time clocks in each node. To implement this service, three algorithms based on different strategies are proposed: one based on an auto-correction approach, the second based on a prediction mechanism, while the third uses an analytical correction mechanism. Their goal is the same, i.e., to make the clocks of the sensor nodes converge as quickly as possible and then to keep them most similar as possible. This goal comes along with the requirement to keep low energy consumption. Differently from other works in the literature, the proposal here is independent of any specific protocol, i.e., it may be adapted to be used in different protocols. Moreover, it explores the minimum number of synchronization messages by means of a smart clock update strategy, allowing the trade-off between the desired level of synchronization and the associated energy consumption. Experimental results, which includes data acquired from simulations and testbed deployments, provide evidence of the success in meeting this goal, as well as providing means to compare these three approaches considering the best synchronization results and their costs in terms of energy consumption.
Highly multiplexed targeted DNA sequencing from single nuclei.
Leung, Marco L; Wang, Yong; Kim, Charissa; Gao, Ruli; Jiang, Jerry; Sei, Emi; Navin, Nicholas E
2016-02-01
Single-cell DNA sequencing methods are challenged by poor physical coverage, high technical error rates and low throughput. To address these issues, we developed a single-cell DNA sequencing protocol that combines flow-sorting of single nuclei, time-limited multiple-displacement amplification (MDA), low-input library preparation, DNA barcoding, targeted capture and next-generation sequencing (NGS). This approach represents a major improvement over our previous single nucleus sequencing (SNS) Nature Protocols paper in terms of generating higher-coverage data (>90%), thereby enabling the detection of genome-wide variants in single mammalian cells at base-pair resolution. Furthermore, by pooling 48-96 single-cell libraries together for targeted capture, this approach can be used to sequence many single-cell libraries in parallel in a single reaction. This protocol greatly reduces the cost of single-cell DNA sequencing, and it can be completed in 5-6 d by advanced users. This single-cell DNA sequencing protocol has broad applications for studying rare cells and complex populations in diverse fields of biological research and medicine.
Energy Consumption Research of Mobile Data Collection Protocol for Underwater Nodes Using an USV.
Lv, Zhichao; Zhang, Jie; Jin, Jiucai; Li, Qi; Gao, Baoru
2018-04-16
The Unmanned Surface Vehicle (USV) integrated with an acoustic modem is a novel mobile vehicle for data collection, which has an advantage in terms of mobility, efficiency, and collection cost. In the scenario of data collection, the USV is controlled autonomously along the planning trajectory and the data of underwater nodes are dynamically collected. In order to improve the efficiency of data collection and extend the life of the underwater nodes, a mobile data collection protocol for underwater nodes using the USV was proposed. In the protocol, the stop-and-wait ARQ transmission mechanism is adopted, where the duty cycle is designed considering the ratio between the sleep mode and the detection mode, and the transmission ratio is defined by the duty cycle, wake-up signal cycles, and USV’s speed. According to protocol, the evaluation index for energy consumption is constructed based on the duty cycle and the transmission ratio. The energy consumption of the protocol is simulated and analyzed using the mobile communication experiment data of USV, taking into consideration USV’s speed, data sequence length, and duty cycle. Optimized protocol parameters are identified, which in turn denotes the proposed protocol’s feasibility and effectiveness.
Commercial Motion Sensor Based Low-Cost and Convenient Interactive Treadmill.
Kim, Jonghyun; Gravunder, Andrew; Park, Hyung-Soon
2015-09-17
Interactive treadmills were developed to improve the simulation of overground walking when compared to conventional treadmills. However, currently available interactive treadmills are expensive and inconvenient, which limits their use. We propose a low-cost and convenient version of the interactive treadmill that does not require expensive equipment and a complicated setup. As a substitute for high-cost sensors, such as motion capture systems, a low-cost motion sensor was used to recognize the subject's intention for speed changing. Moreover, the sensor enables the subject to make a convenient and safe stop using gesture recognition. For further cost reduction, the novel interactive treadmill was based on an inexpensive treadmill platform and a novel high-level speed control scheme was applied to maximize performance for simulating overground walking. Pilot tests with ten healthy subjects were conducted and results demonstrated that the proposed treadmill achieves similar performance to a typical, costly, interactive treadmill that contains a motion capture system and an instrumented treadmill, while providing a convenient and safe method for stopping.
Low-earth-orbit Satellite Internet Protocol Communications Concept and Design
NASA Technical Reports Server (NTRS)
Slywezak, Richard A.
2004-01-01
This report presents a design concept for a low-Earth-orbit end-to-end Internet-Protocol- (IP-) based mission. The goal is to maintain an up-to-date communications infrastructure that makes communications seamless with the protocols used in terrestrial computing. It is based on the premise that the use of IPs will permit greater interoperability while also reducing costs and providing users the ability to retrieve data directly from the satellite. However, implementing an IP-based solution also has a number of challenges, since wireless communications have different characteristics than wired communications. This report outlines the design of a low-Earth-orbit end-to-end IP-based mission; the ideas and concepts of Space Internet architectures and networks are beyond the scope of this document. The findings of this report show that an IP-based mission is plausible and would provide benefits to the user community, but the outstanding issues must be resolved before a design can be implemented.
Operational performance of a low cost, air mass 2 solar simulator
NASA Technical Reports Server (NTRS)
Yass, K.; Curtis, H. B.
1975-01-01
Modifications and improvements on a low cost air mass 2 solar simulator are discussed. The performance characteristics of total irradiance, uniformity of irradiance, spectral distribution, and beam subtense angle are presented. The simulator consists of an array of tungsten halogen lamps hexagonally spaced in a plane. A corresponding array of plastic Fresnel lenses shapes the output beam such that the simulator irradiates a 1.2 m by 1.2 m area with uniform collimated irradiance. Details are given concerning individual lamp output measurements and placement of the lamps. Originally, only the direct component of solar irradiance was simulated. Since the diffuse component may affect the performance of some collectors, the capability to simulate it is being added. An approach to this diffuse addition is discussed.
Saleem, Kashif; Derhab, Abdelouahid; Orgun, Mehmet A; Al-Muhtadi, Jalal; Rodrigues, Joel J P C; Khalil, Mohammed Sayim; Ali Ahmed, Adel
2016-03-31
The deployment of intelligent remote surveillance systems depends on wireless sensor networks (WSNs) composed of various miniature resource-constrained wireless sensor nodes. The development of routing protocols for WSNs is a major challenge because of their severe resource constraints, ad hoc topology and dynamic nature. Among those proposed routing protocols, the biology-inspired self-organized secure autonomous routing protocol (BIOSARP) involves an artificial immune system (AIS) that requires a certain amount of time to build up knowledge of neighboring nodes. The AIS algorithm uses this knowledge to distinguish between self and non-self neighboring nodes. The knowledge-building phase is a critical period in the WSN lifespan and requires active security measures. This paper proposes an enhanced BIOSARP (E-BIOSARP) that incorporates a random key encryption mechanism in a cost-effective manner to provide active security measures in WSNs. A detailed description of E-BIOSARP is presented, followed by an extensive security and performance analysis to demonstrate its efficiency. A scenario with E-BIOSARP is implemented in network simulator 2 (ns-2) and is populated with malicious nodes for analysis. Furthermore, E-BIOSARP is compared with state-of-the-art secure routing protocols in terms of processing time, delivery ratio, energy consumption, and packet overhead. The findings show that the proposed mechanism can efficiently protect WSNs from selective forwarding, brute-force or exhaustive key search, spoofing, eavesdropping, replaying or altering of routing information, cloning, acknowledgment spoofing, HELLO flood attacks, and Sybil attacks.
Saleem, Kashif; Derhab, Abdelouahid; Orgun, Mehmet A.; Al-Muhtadi, Jalal; Rodrigues, Joel J. P. C.; Khalil, Mohammed Sayim; Ali Ahmed, Adel
2016-01-01
The deployment of intelligent remote surveillance systems depends on wireless sensor networks (WSNs) composed of various miniature resource-constrained wireless sensor nodes. The development of routing protocols for WSNs is a major challenge because of their severe resource constraints, ad hoc topology and dynamic nature. Among those proposed routing protocols, the biology-inspired self-organized secure autonomous routing protocol (BIOSARP) involves an artificial immune system (AIS) that requires a certain amount of time to build up knowledge of neighboring nodes. The AIS algorithm uses this knowledge to distinguish between self and non-self neighboring nodes. The knowledge-building phase is a critical period in the WSN lifespan and requires active security measures. This paper proposes an enhanced BIOSARP (E-BIOSARP) that incorporates a random key encryption mechanism in a cost-effective manner to provide active security measures in WSNs. A detailed description of E-BIOSARP is presented, followed by an extensive security and performance analysis to demonstrate its efficiency. A scenario with E-BIOSARP is implemented in network simulator 2 (ns-2) and is populated with malicious nodes for analysis. Furthermore, E-BIOSARP is compared with state-of-the-art secure routing protocols in terms of processing time, delivery ratio, energy consumption, and packet overhead. The findings show that the proposed mechanism can efficiently protect WSNs from selective forwarding, brute-force or exhaustive key search, spoofing, eavesdropping, replaying or altering of routing information, cloning, acknowledgment spoofing, HELLO flood attacks, and Sybil attacks. PMID:27043572
Robust and Cost-Efficient Communication Based on SNMP in Mobile Networks
NASA Astrophysics Data System (ADS)
Ryu, Sang-Hoon; Baik, Doo-Kwon
A main challenge in the design of this mobile network is the development of dynamic routing protocols that can efficiently find routes between two communicating nodes. Multimedia streaming services are receiving considerable interest in the mobile network business. An entire mobile network may change its point of attachment to the Internet. The mobile network is operated by a basic specification to support network mobility called Network Mobility (NEMO) Basic Support. However, NEMO basic Support mechanism has some problem in continuous communication. In this paper, we propose robust and cost-efficient algorithm. And we simulate proposed method and conclude some remarks.
Boccia, Maria L; Campbell, Frances A; Goldman, Barbara D; Skinner, Martie
2009-01-01
In the present simulation research, the authors examined the relations between the type of information that low-income parents (N = 116) recalled from informed-consent materials and their hypothetical decision to enroll a child in a clinical study. The authors gave parents or guardians of Head Start children information about a medical protocol involving high risk and significant potential benefit to child participants. Differential recall of the various categories of information (procedures, benefits, risks and costs, rights, and other) showed that relative to all consent information conveyed to them, participants recalled most about procedures and least about their child's rights as a study participant. Relative to their own recall, they also recounted most about procedures, slightly more about benefits than risks, and least about research rights. The pattern of recall differed among those who agreed to enroll and those who declined. The ratio of recalled risks to benefits predicted enrollment decisions.
NASA Astrophysics Data System (ADS)
Zwolak, Michael
2013-03-01
A rapid and low-cost method to sequence DNA would revolutionize personalized medicine, where genetic information is used to diagnose, treat, and prevent diseases. There is a longstanding interest in nanopores as a platform for rapid interrogation of single DNA molecules. I will discuss a sequencing protocol based on the measurement of transverse electronic currents during the translocation of single-stranded DNA through nanopores. Using molecular dynamics simulations coupled to quantum mechanical calculations of the tunneling current, I will show that the DNA nucleotides are predicted to have distinguishable electronic signatures in experimentally realizable systems. Several recent experiments support our theoretical predictions. In addition to their possible impact in medicine and biology, the above methods offer ideal test beds to study open scientific issues in the relatively unexplored area at the interface between solids, liquids, and biomolecules at the nanometer length scale. http://mike.zwolak.org
A Hierarchical Communication Architecture for Oceanic Surveillance Applications
Macias, Elsa; Suarez, Alvaro; Chiti, Francesco; Sacco, Andrea; Fantacci, Romano
2011-01-01
The interest in monitoring applications using underwater sensor networks has been growing in recent years. The severe communication restrictions imposed by underwater channels make that efficient monitoring be a challenging task. Though a lot of research has been conducted on underwater sensor networks, there are only few concrete applications to a real-world case study. In this work, hence, we propose a general three tier architecture leveraging low cost wireless technologies for acoustic communications between underwater sensors and standard technologies, Zigbee and Wireless Fidelity (WiFi), for water surface communications. We have selected a suitable Medium Access Control (MAC) layer, after making a comparison with some common MAC protocols. Thus the performance of the overall system in terms of Signals Discarding Rate (SDR), signalling delay at the surface gateway as well as the percentage of true detection have been evaluated by simulation, pointing out good results which give evidence in applicability’s favour. PMID:22247669
The ability of flexible car bonnets to mitigate the consequences of frontal impact with pedestrians
NASA Astrophysics Data System (ADS)
Stanisławek, Sebastian; Niezgoda, Tadeusz
2018-01-01
The paper presents the results of numerical research on a vehicle representing a Toyota Yaris passenger sedan hitting a pedestrian. A flexible car body is suggested as an interesting way to increase safety. The authors present a simple low-cost bonnet buffer concept that may mitigate the effects of frontal impact. Computer simulation was the method chosen to solve the problem efficiently. The Finite Element Method (FEM) implemented in the LS-DYNA commercial code was used. The testing procedure was based on the Euro NCAP protocol. A flexible bonnet buffer shows its usefulness in preventing casualties in typical accidents. In the best scenario, the HIC15 parameter is only 380 when such a buffer is installed. In comparison, an accident involving a car without any protection produces an HIC15 of 970, which is very dangerous for pedestrians.
van der Heijden, Amber A W A; de Bruijne, Martine C; Feenstra, Talitha L; Dekker, Jacqueline M; Baan, Caroline A; Bosmans, Judith E; Bot, Sandra D M; Donker, Gé A; Nijpels, Giel
2014-06-25
The increasing prevalence of diabetes is associated with increased health care use and costs. Innovations to improve the quality of care, manage the increasing demand for health care and control the growth of health care costs are needed. The aim of this study is to evaluate the care process and costs of managed, protocolized and usual care for type 2 diabetes patients from a societal perspective. In two distinct regions of the Netherlands, both managed and protocolized diabetes care were implemented. Managed care was characterized by centralized organization, coordination, responsibility and centralized annual assessment. Protocolized care had a partly centralized organizational structure. Usual care was characterized by a decentralized organizational structure. Using a quasi-experimental control group pretest-posttest design, the care process (guideline adherence) and costs were compared between managed (n = 253), protocolized (n = 197), and usual care (n = 333). We made a distinction between direct health care costs, direct non-health care costs and indirect costs. Multivariate regression models were used to estimate differences in costs adjusted for confounding factors. Because of the skewed distribution of the costs, bootstrapping methods (5000 replications) with a bias-corrected and accelerated approach were used to estimate 95% confidence intervals (CI) around the differences in costs. Compared to usual and protocolized care, in managed care more patients were treated according to diabetes guidelines. Secondary health care use was higher in patients under usual care compared to managed and protocolized care. Compared to usual care, direct costs were significantly lower in managed care (€-1.181 (95% CI: -2.597 to -334)) while indirect costs were higher (€ 758 (95% CI: -353 to 2.701), although not significant. Direct, indirect and total costs were lower in protocolized care compared to usual care (though not significantly). Compared to usual care, managed care was significantly associated with better process in terms of diabetes care, fewer secondary care consultations and lower health care costs. The same trends were seen for protocolized care, however they were not statistically significant. Current Controlled trials: ISRCTN66124817.
2014-01-01
Background The increasing prevalence of diabetes is associated with increased health care use and costs. Innovations to improve the quality of care, manage the increasing demand for health care and control the growth of health care costs are needed. The aim of this study is to evaluate the care process and costs of managed, protocolized and usual care for type 2 diabetes patients from a societal perspective. Methods In two distinct regions of the Netherlands, both managed and protocolized diabetes care were implemented. Managed care was characterized by centralized organization, coordination, responsibility and centralized annual assessment. Protocolized care had a partly centralized organizational structure. Usual care was characterized by a decentralized organizational structure. Using a quasi-experimental control group pretest-posttest design, the care process (guideline adherence) and costs were compared between managed (n = 253), protocolized (n = 197), and usual care (n = 333). We made a distinction between direct health care costs, direct non-health care costs and indirect costs. Multivariate regression models were used to estimate differences in costs adjusted for confounding factors. Because of the skewed distribution of the costs, bootstrapping methods (5000 replications) with a bias-corrected and accelerated approach were used to estimate 95% confidence intervals (CI) around the differences in costs. Results Compared to usual and protocolized care, in managed care more patients were treated according to diabetes guidelines. Secondary health care use was higher in patients under usual care compared to managed and protocolized care. Compared to usual care, direct costs were significantly lower in managed care (€-1.181 (95% CI: -2.597 to -334)) while indirect costs were higher (€758 (95% CI: -353 to 2.701), although not significant. Direct, indirect and total costs were lower in protocolized care compared to usual care (though not significantly). Conclusions Compared to usual care, managed care was significantly associated with better process in terms of diabetes care, fewer secondary care consultations and lower health care costs. The same trends were seen for protocolized care, however they were not statistically significant. Trial registration Current Controlled trials: ISRCTN66124817. PMID:24966055
Vyas, A; Goel, G
2017-09-01
Minimal invasive surgery training requires a lot of practice and for this purpose innovative tools are needed to develop methods for practice and training skills outside the operating room. Commercially available devices are readily available but cost effectiveness and availability are major limiting factors in resource limited setting. We present an innovative and cost effective laparoscopic simulator which can be easily manufactured and used for practice of laparoscopic surgery. Using a free android application, such as IP webcam we can relay video to laptop without the use of any cables and uniquely we use the flash of a camera as the light source and a selfie stick for movement of the camera. Use of this type of setup can help to reduce cost of simulated learning in low income countries and makes laparoscopic training facilities readily available. Copyright© Authors.
Campos, Nicole G.; Castle, Philip E.; Wright, Thomas C.; Kim, Jane J.
2016-01-01
As cervical cancer screening programs are implemented in low-resource settings, protocols are needed to maximize health benefits under operational constraints. Our objective was to develop a framework for examining health and economic tradeoffs between screening test sensitivity, population coverage, and follow-up of screen-positive women, to help decision makers identify where program investments yield the greatest value. As an illustrative example, we used an individual-based Monte Carlo simulation model of the natural history of human papillomavirus (HPV) and cervical cancer calibrated to epidemiologic data from Uganda. We assumed once in a lifetime screening at age 35 with two-visit HPV DNA testing or one-visit visual inspection with acetic acid (VIA). We assessed the health and economic tradeoffs that arise between 1) test sensitivity and screening coverage; 2) test sensitivity and loss to follow-up (LTFU) of screen-positive women; and 3) test sensitivity, screening coverage, and LTFU simultaneously. The decline in health benefits associated with sacrificing HPV DNA test sensitivity by 20% (e.g., shifting from provider- to self-collection of specimens) could be offset by gains in coverage if coverage increased by at least 20%. When LTFU was 10%, two-visit HPV DNA testing with 80-90% sensitivity was more effective and more cost-effective than one-visit VIA with 40% sensitivity, and yielded greater health benefits than VIA even as VIA sensitivity increased to 60% and HPV test sensitivity declined to 70%. As LTFU increased, two-visit HPV DNA testing became more costly and less effective than one-visit VIA. Setting-specific data on achievable test sensitivity, coverage, follow-up rates, and programmatic costs are needed to guide programmatic decision making for cervical cancer screening. PMID:25943074
Jenkins, Paul J; McDonald, David A; Van Der Meer, Robert; Morton, Alec; Nugent, Margaret; Rymaszewski, Lech A
2017-01-01
Objective Healthcare faces the continual challenge of improving outcome while aiming to reduce cost. The aim of this study was to determine the micro cost differences of the Glasgow non-operative trauma virtual pathway in comparison to a traditional pathway. Design Discrete event simulation was used to model and analyse cost and resource utilisation with an activity-based costing approach. Data for a full comparison before the process change was unavailable so we used a modelling approach, comparing a virtual fracture clinic (VFC) with a simulated traditional fracture clinic (TFC). Setting The orthopaedic unit VFC pathway pioneered at Glasgow Royal Infirmary has attracted significant attention and interest and is the focus of this cost study. Outcome measures Our study focused exclusively on patients with non-operative trauma attending emergency department or the minor injuries unit and the subsequent step in the patient pathway. Retrospective studies of patient outcomes as a result of the protocol introductions for specific injuries are presented in association with activity costs from the models. Results Patients are satisfied with the new pathway, the information provided and the outcome of their injuries (Evidence Level IV). There was a 65% reduction in the number of first outpatient face-to-face (f2f) attendances in orthopaedics. In the VFC pathway, the resources required per day were significantly lower for all staff groups (p≤0.001). The overall cost per patient of the VFC pathway was £22.84 (95% CI 21.74 to 23.92) per patient compared with £36.81 (95% CI 35.65 to 37.97) for the TFC pathway. Conclusions Our results give a clearer picture of the cost comparison of the virtual pathway over a wholly traditional f2f clinic system. The use of simulation-based stochastic costings in healthcare economic analysis has been limited to date, but this study provides evidence for adoption of this method as a basis for its application in other healthcare settings. PMID:28882905
Tosi, L L; Detsky, A S; Roye, D P; Morden, M L
1987-01-01
Using a decision analysis model, we estimated the savings that might be derived from a mass prenatal screening program aimed at detecting open neural tube defects (NTDs) in low-risk pregnancies. Our baseline analysis showed that screening v. no screening could be expected to save approximately $8 per pregnancy given a cost of $7.50 for the maternal serum alpha-feto-protein (MSAFP) test and a cost of $42,507 for hospital and rehabilitation services for the first 10 years of life for a child with spina bifida. When a more liberal estimate of the costs of caring for such a child was used, the savings with the screening program were more substantial. We performed extensive sensitivity analyses, which showed that the savings were somewhat sensitive to the cost of the MSAFP test and highly sensitive to the specificity (but not the sensitivity) of the test. A screening program for NTDs in low-risk pregnancies may result in substantial savings in direct health care costs if the screening protocol is followed rigorously and efficiently. PMID:2433011
Isaranuwatchai, Wanrudee; Brydges, Ryan; Carnahan, Heather; Backstein, David; Dubrowski, Adam
2014-05-01
While the ultimate goal of simulation training is to enhance learning, cost-effectiveness is a critical factor. Research that compares simulation training in terms of educational- and cost-effectiveness will lead to better-informed curricular decisions. Using previously published data we conducted a cost-effectiveness analysis of three simulation-based programs. Medical students (n = 15 per group) practiced in one of three 2-h intravenous catheterization skills training programs: low-fidelity (virtual reality), high-fidelity (mannequin), or progressive (consisting of virtual reality, task trainer, and mannequin simulator). One week later, all performed a transfer test on a hybrid simulation (standardized patient with a task trainer). We used a net benefit regression model to identify the most cost-effective training program via paired comparisons. We also created a cost-effectiveness acceptability curve to visually represent the probability that one program is more cost-effective when compared to its comparator at various 'willingness-to-pay' values. We conducted separate analyses for implementation and total costs. The results showed that the progressive program had the highest total cost (p < 0.001) whereas the high-fidelity program had the highest implementation cost (p < 0.001). While the most cost-effective program depended on the decision makers' willingness-to-pay value, the progressive training program was generally most educationally- and cost-effective. Our analyses suggest that a progressive program that strategically combines simulation modalities provides a cost-effective solution. More generally, we have introduced how a cost-effectiveness analysis may be applied to simulation training; a method that medical educators may use to investment decisions (e.g., purchasing cost-effective and educationally sound simulators).
Yun, Kang-Seop; Pai, Sung Jin; Yeo, Byung Chul; Lee, Kwang-Ryeol; Kim, Sun-Jae; Han, Sang Soo
2017-07-06
We propose the ReaxFF reactive force field as a simulation protocol for predicting the evolution of solid-electrolyte interphase (SEI) components such as gases (C 2 H 4 , CO, CO 2 , CH 4 , and C 2 H 6 ), and inorganic (Li 2 CO 3 , Li 2 O, and LiF) and organic (ROLi and ROCO 2 Li: R = -CH 3 or -C 2 H 5 ) products that are generated by the chemical reactions between the anodes and liquid electrolytes. ReaxFF was developed from ab initio results, and a molecular dynamics simulation with ReaxFF realized the prediction of SEI formation under real experimental conditions and with a reasonable computational cost. We report the effects on SEI formation of different kinds of Si anodes (pristine Si and SiO x ), of the different types and compositions of various carbonate electrolytes, and of the additives. From the results, we expect that ReaxFF will be very useful for the development of novel electrolytes or additives and for further advances in Li-ion battery technology.
An economic evaluation of intervention strategies for Porcine Epidemic Diarrhea (PED).
Weng, Longfeng; Weersink, Alfons; Poljak, Zvonimir; de Lange, Kees; von Massow, Mike
2016-11-01
The economic losses of Porcine Epidemic Diarrhea (PED) and the net benefits of strategies to control the virus are calculated for individual farrow-to-finish herds. A production simulation model that estimates the number of pigs by population cohorts on a weekly basis for a farrow-to-finish farm depending on production parameters is simulated under normal operating conditions and then with an outbreak of PED. The estimated annual costs of a PED outbreak with the closure of the breeding herd as the only intervention is approximately $300,000 for a 700-sow farrow-to-finishing herd. The net returns per sow (hog) fall from $255 ($11.54) to a loss of $174 ($10.68). These losses can be significantly reduced with any of the 16 intervention strategies considered in this study. The most profitable strategy involving front loading of gilts with average feedback of infected material to improve herd immunity, intensive biosecurity protocols and no vaccination costs $27,000 to implement but reduces losses by 10 times this amount. Even the implementation of the least comprehensive strategy, which involves back-loading gilts after the herd reopens and an average feedback practice at a cost of $1000 reduces the losses caused by a PED outbreak by $130,000. Front-loading gilts in combination with herd closure is more cost-effective than back-loading. Despite the extra spending on intensive biosecurity protocols, the overall loss reductions achieved by the intensive biosecurity effort can be significant. Vaccination is the least cost-effective of the intervention practices considered. Even with significant increases in cost or effectiveness in the practices, intervention is justified across all strategies. The spreadsheet model of a farrow-finish hog farm developed in this study can be used to examine changes to the production parameters or to consider other swine disease outbreaks. Copyright © 2016 Elsevier B.V. All rights reserved.
Rogers, Rebecca G; Gardner, Michael O; Tool, Kevin J; Ainsley, Jeanne; Gilson, George
2000-01-01
Objective To compare the costs of a protocol of active management of labor with those of traditional labor management. Design Cost analysis of a randomized controlled trial. Methods From August 1992 to April 1996, we randomly allocated 405 women whose infants were delivered at the University of New Mexico Health Sciences Center, Albuquerque, to an active management of labor protocol that had substantially reduced the duration of labor or a control protocol. We calculated the average cost for each delivery, using both actual costs and charges. Results The average cost for women assigned to the active management protocol was $2,480.79 compared with an average cost of $2,528.61 for women in the control group (P = 0.55). For women whose infant was delivered by cesarean section, the average cost was $4,771.54 for active management of labor and $4,468.89 for the control protocol (P = 0.16). Spontaneous vaginal deliveries cost an average of $27.00 more for actively managed patients compared with the cost for the control protocol. Conclusions The reduced duration of labor by active management did not translate into significant cost savings. Overall, an average cost saving of only $47.91, or 2%, was achieved for labors that were actively managed. This reduction in cost was due to a decrease in the rate of cesarean sections in women whose labor was actively managed and not to a decreased duration of labor. PMID:10778374
Wagner, Michael; Mileder, Lukas P; Goeral, Katharina; Klebermass-Schrehof, Katrin; Cardona, Francesco S; Berger, Angelika; Schmölzer, Georg M; Olischar, Monika
2017-06-01
The World Health Organization recommends regular simulation training to prevent adverse healthcare events. We used specially trained medical students to provide paediatric simulation training to their peers and assessed feasibility, cost and confidence of students who attended the courses. Students at the Medical University of Vienna, Austria were eligible to participate. Students attended two high-fidelity simulation training sessions, delivered by peers, which were videorecorded for evaluation. The attendees then completed questionnaires before and after the training. Associated costs and potential benefits were analysed. From May 2013 to June 2015, 152 students attended the sessions and 57 (37.5%) completed both questionnaires. Satisfaction was high, with 95% stating their peer tutor was competent and 90% saying that peer tutors were well prepared. The attendees' confidence in treating critically ill children significantly improved after training (p < 0.001). The average costs for a peer tutor were six Euros per working hour, compared to 35 Euros for a physician. Using peer tutors for paediatric simulation training was a feasible and low-cost option that increased the number of medical students who could be trained and increased the self-confidence of the attendees. Satisfaction with the peer tutors was high. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
A Communications Network for Cislunar Operations
NASA Technical Reports Server (NTRS)
Burleigh, Scott
2012-01-01
Reliable and efficient communications will be critical to the success of commercial flight operations in cislunar space. The Internet is not well-suited to meeting this requirement. But the Delay-Tolerant Networking (DTN) architecture is. The DTN protocols are well-documented and implementations are mature. We think DTN will be ready to support low-cost, low-risk cislunar networking by the time the vehicles are in place.
An Alternative Wearable Tracking System Based on a Low-Power Wide-Area Network
Fernández-Garcia, Raul; Gil, Ignacio
2017-01-01
This work presents an alternative wearable tracking system based on a low-power wide area network. A complete GPS receiver was integrated with a textile substrate, and the latitude and longitude coordinates were sent to the cloud by means of the SIM-less SIGFOX network. To send the coordinates over SIGFOX protocol, a specific codification algorithm was used and a customized UHF antenna on jeans fabric was designed, simulated and tested. Moreover, to guarantee the compliance to international regulations for human body exposure to electromagnetic radiation, the electromagnetic specific absorption rate of this antenna was analyzed. A specific remote server was developed to decode the latitude and longitude coordinates. Once the coordinates have been decoded, the remote server sends this information to the open source data viewer SENTILO to show the location of the sensor node in a map. The functionality of this system has been demonstrated experimentally. The results guarantee the utility and wearability of the proposed tracking system for the development of sensor nodes and point out that it can be a low cost alternative to other commercial products based on GSM networks. PMID:28335424
Flexray - An Answer to the Challenges Faced by Spacecraft On-Board Communication Protocols
NASA Astrophysics Data System (ADS)
Gunes-Lasnet, S.; Furano, G.
2007-08-01
The current spacecraft on-board network protocols are facing challenges: They need to consume low power, to handle a high data rate, and eventually need to have real-time capabilities as well as fault-tolerance; all of this at a low cost. Meanwhile, the automotive protocols are showing ever increasing enhanced performances: the automotive industry has shown recent break-throughs in communication networks. Among them, FlexRay targets specifically the next generation of automotive applications allowing Steer-by-Wire and Brake-by- Wire. FlexRay supports a very high data rate, is fault- tolerant, has real-time capabilities, and supports both periodic and aperiodic data transfer on a single bus. Space avionics has benefited from the automotive spin- ins in the past, so could FlexRay answer the space systems demands? This paper aims at demonstrating that space avionics could profit from the use of FlexRay.
The fusion of satellite and UAV data: simulation of high spatial resolution band
NASA Astrophysics Data System (ADS)
Jenerowicz, Agnieszka; Siok, Katarzyna; Woroszkiewicz, Malgorzata; Orych, Agata
2017-10-01
Remote sensing techniques used in the precision agriculture and farming that apply imagery data obtained with sensors mounted on UAV platforms became more popular in the last few years due to the availability of low- cost UAV platforms and low- cost sensors. Data obtained from low altitudes with low- cost sensors can be characterised by high spatial and radiometric resolution but quite low spectral resolution, therefore the application of imagery data obtained with such technology is quite limited and can be used only for the basic land cover classification. To enrich the spectral resolution of imagery data acquired with low- cost sensors from low altitudes, the authors proposed the fusion of RGB data obtained with UAV platform with multispectral satellite imagery. The fusion is based on the pansharpening process, that aims to integrate the spatial details of the high-resolution panchromatic image with the spectral information of lower resolution multispectral or hyperspectral imagery to obtain multispectral or hyperspectral images with high spatial resolution. The key of pansharpening is to properly estimate the missing spatial details of multispectral images while preserving their spectral properties. In the research, the authors presented the fusion of RGB images (with high spatial resolution) obtained with sensors mounted on low- cost UAV platforms and multispectral satellite imagery with satellite sensors, i.e. Landsat 8 OLI. To perform the fusion of UAV data with satellite imagery, the simulation of the panchromatic bands from RGB data based on the spectral channels linear combination, was conducted. Next, for simulated bands and multispectral satellite images, the Gram-Schmidt pansharpening method was applied. As a result of the fusion, the authors obtained several multispectral images with very high spatial resolution and then analysed the spatial and spectral accuracies of processed images.
Lelijveld, Natasha; Bailey, Jeanette; Mayberry, Amy; Trenouth, Lani; N'Diaye, Dieynaba S; Haghparast-Bidgoli, Hassan; Puett, Chloe
2018-04-24
Acute malnutrition is currently divided into severe (SAM) and moderate (MAM) based on level of wasting. SAM and MAM currently have separate treatment protocols and products, managed by separate international agencies. For SAM, the dose of treatment is allocated by the child's weight. A combined and simplified protocol for SAM and MAM, with a standardised dose of ready-to-use therapeutic food (RUTF), is being trialled for non-inferior recovery rates and may be more cost-effective than the current standard protocols for treating SAM and MAM. This is the protocol for the economic evaluation of the ComPAS trial, a cluster-randomised controlled, non-inferiority trial that compares a novel combined protocol for treating uncomplicated acute malnutrition compared to the current standard protocol in South Sudan and Kenya. We will calculate the total economic costs of both protocols from a societal perspective, using accounting data, interviews and survey questionnaires. The incremental cost of implementing the combined protocol will be estimated, and all costs and outcomes will be presented as a cost-consequence analysis. Incremental cost-effectiveness ratio will be calculated for primary and secondary outcome, if statistically significant. We hypothesise that implementing the combined protocol will be cost-effective due to streamlined logistics at clinic level, reduced length of treatment, especially for MAM, and reduced dosages of RUTF. The findings of this economic evaluation will be important for policymakers, especially given the hypothesised non-inferiority of the main health outcomes. The publication of this protocol aims to improve rigour of conduct and transparency of data collection and analysis. It is also intended to promote inclusion of economic evaluation in other nutrition intervention studies, especially for MAM, and improve comparability with other studies. ISRCTN 30393230 , date: 16/03/2017.
Holland, Christine M; Ritchie, Natalie D; Du Bois, Steve N
2015-10-01
This brief report describes methodology and results of a novel, efficient, and low-cost recruitment tool to engage high-risk MSM in online research. We developed an incentivization protocol using iTunes song-gifting to encourage participation of high-risk MSM in an Internet-based survey of HIV status, childhood sexual abuse, and adult behavior and functioning. Our recruitment methodology yielded 489 participants in 4.5 months at a total incentive cost of $1.43USD per participant. The sample comprised a critically high-risk group of MSM, including 71.0 % who reported recent condomless anal intercourse. We offer a "how-to" guide to aid future investigators in using iTunes song-gifting incentives.
Security Analysis and Improvements of Authentication and Access Control in the Internet of Things
Ndibanje, Bruce; Lee, Hoon-Jae; Lee, Sang-Gon
2014-01-01
Internet of Things is a ubiquitous concept where physical objects are connected over the internet and are provided with unique identifiers to enable their self-identification to other devices and the ability to continuously generate data and transmit it over a network. Hence, the security of the network, data and sensor devices is a paramount concern in the IoT network as it grows very fast in terms of exchanged data and interconnected sensor nodes. This paper analyses the authentication and access control method using in the Internet of Things presented by Jing et al (Authentication and Access Control in the Internet of Things. In Proceedings of the 2012 32nd International Conference on Distributed Computing Systems Workshops, Macau, China, 18–21 June 2012, pp. 588–592). According to our analysis, Jing et al.'s protocol is costly in the message exchange and the security assessment is not strong enough for such a protocol. Therefore, we propose improvements to the protocol to fill the discovered weakness gaps. The protocol enhancements facilitate many services to the users such as user anonymity, mutual authentication, and secure session key establishment. Finally, the performance and security analysis show that the improved protocol possesses many advantages against popular attacks, and achieves better efficiency at low communication cost. PMID:25123464
Security analysis and improvements of authentication and access control in the Internet of Things.
Ndibanje, Bruce; Lee, Hoon-Jae; Lee, Sang-Gon
2014-08-13
Internet of Things is a ubiquitous concept where physical objects are connected over the internet and are provided with unique identifiers to enable their self-identification to other devices and the ability to continuously generate data and transmit it over a network. Hence, the security of the network, data and sensor devices is a paramount concern in the IoT network as it grows very fast in terms of exchanged data and interconnected sensor nodes. This paper analyses the authentication and access control method using in the Internet of Things presented by Jing et al. (Authentication and Access Control in the Internet of Things. In Proceedings of the 2012 32nd International Conference on Distributed Computing Systems Workshops, Macau, China, 18-21 June 2012, pp. 588-592). According to our analysis, Jing et al.'s protocol is costly in the message exchange and the security assessment is not strong enough for such a protocol. Therefore, we propose improvements to the protocol to fill the discovered weakness gaps. The protocol enhancements facilitate many services to the users such as user anonymity, mutual authentication, and secure session key establishment. Finally, the performance and security analysis show that the improved protocol possesses many advantages against popular attacks, and achieves better efficiency at low communication cost.
Characterization of tissue-simulating phantom materials for ultrasound-guided needle procedures
NASA Astrophysics Data System (ADS)
Buchanan, Susan; Moore, John; Lammers, Deanna; Baxter, John; Peters, Terry
2012-02-01
Needle biopsies are standard protocols that are commonly performed under ultrasound (US) guidance or computed tomography (CT)1. Vascular access such as central line insertions, and many spinal needle therapies also rely on US guidance. Phantoms for these procedures are crucial as both training tools for clinicians and research tools for developing new guidance systems. Realistic imaging properties and material longevity are critical qualities for needle guidance phantoms. However, current commercially available phantoms for use with US guidance have many limitations, the most detrimental of which include harsh needle tracks obfuscating US images and a membrane comparable to human skin that does not allow seepage of inner media. To overcome these difficulties, we tested a variety of readily available media and membranes to evaluate optimal materials to fit our current needs. It was concluded that liquid hand soap was the best medium, as it instantly left no needle tracks, had an acceptable depth of US penetration and portrayed realistic imaging conditions, while because of its low leakage, low cost, acceptable durability and transparency, the optimal membrane was 10 gauge vinyl.
Amsterdam, Ezra A; Kirk, J Douglas; Bluemke, David A; Diercks, Deborah; Farkouh, Michael E; Garvey, J Lee; Kontos, Michael C; McCord, James; Miller, Todd D; Morise, Anthony; Newby, L Kristin; Ruberg, Frederick L; Scordo, Kristine Anne; Thompson, Paul D
2010-10-26
The management of low-risk patients presenting to emergency departments is a common and challenging clinical problem entailing 8 million emergency department visits annually. Although a majority of these patients do not have a life-threatening condition, the clinician must distinguish between those who require urgent treatment of a serious problem and those with more benign entities who do not require admission. Inadvertent discharge of patients with acute coronary syndrome from the emergency department is associated with increased mortality and liability, whereas inappropriate admission of patients without serious disease is neither indicated nor cost-effective. Clinical judgment and basic clinical tools (history, physical examination, and electrocardiogram) remain primary in meeting this challenge and affording early identification of low-risk patients with chest pain. Additionally, established and newer diagnostic methods have extended clinicians' diagnostic capacity in this setting. Low-risk patients presenting with chest pain are increasingly managed in chest pain units in which accelerated diagnostic protocols are performed, comprising serial electrocardiograms and cardiac injury markers to exclude acute coronary syndrome. Patients with negative findings usually complete the accelerated diagnostic protocol with a confirmatory test to exclude ischemia. This is typically an exercise treadmill test or a cardiac imaging study if the exercise treadmill test is not applicable. Rest myocardial perfusion imaging has assumed an important role in this setting. Computed tomography coronary angiography has also shown promise in this setting. A negative accelerated diagnostic protocol evaluation allows discharge, whereas patients with positive findings are admitted. This approach has been found to be safe, accurate, and cost-effective in low-risk patients presenting with chest pain.
Lin, Chinsu; Thomson, Gavin; Hung, Shih-Hsiang; Lin, Yu-Dung
2012-12-30
This study introduces a GIS-based protocol for the simulation and evaluation of thinning treatments in recreational forest management. The protocol was implemented in a research study based on an area of recreational forest in Alishan National Scenic Area, Taiwan. Ground survey data were mapped to a GIS database, to create a precise, yet flexible, GIS-based digital forest. The digital forest model was used to generate 18 different thinning scenario images and one image of the existing unthinned forest. A questionnaire was completed by 456 participants while simultaneously viewing the scenario images. The questionnaire was used to determine the scenic beauty preferences of the respondents. Statistical analysis of the data revealed that the respondents preferred low density, upper-storey thinning treatments and a dispersed retention pattern of the remaining trees. High density upper-storey treatments evoked a strongly negative reaction in the observers. The experiment demonstrated that the proposed protocol is suitable for selecting an appropriate thinning strategy for recreational forest and that the protocol has practical value in recreational forest management. Copyright © 2012 Elsevier Ltd. All rights reserved.
A Novel Cross-Layer Routing Protocol Based on Network Coding for Underwater Sensor Networks
Wang, Hao; Wang, Shilian; Bu, Renfei; Zhang, Eryang
2017-01-01
Underwater wireless sensor networks (UWSNs) have attracted increasing attention in recent years because of their numerous applications in ocean monitoring, resource discovery and tactical surveillance. However, the design of reliable and efficient transmission and routing protocols is a challenge due to the low acoustic propagation speed and complex channel environment in UWSNs. In this paper, we propose a novel cross-layer routing protocol based on network coding (NCRP) for UWSNs, which utilizes network coding and cross-layer design to greedily forward data packets to sink nodes efficiently. The proposed NCRP takes full advantages of multicast transmission and decode packets jointly with encoded packets received from multiple potential nodes in the entire network. The transmission power is optimized in our design to extend the life cycle of the network. Moreover, we design a real-time routing maintenance protocol to update the route when detecting inefficient relay nodes. Substantial simulations in underwater environment by Network Simulator 3 (NS-3) show that NCRP significantly improves the network performance in terms of energy consumption, end-to-end delay and packet delivery ratio compared with other routing protocols for UWSNs. PMID:28786915
NASA Astrophysics Data System (ADS)
Elbakary, Mohamed I.; Iftekharuddin, Khan M.; Papelis, Yiannis; Newman, Brett
2017-05-01
Air Traffic Management (ATM) concepts are commonly tested in simulation to obtain preliminary results and validate the concepts before adoption. Recently, the researchers found that simulation is not enough because of complexity associated with ATM concepts. In other words, full-scale tests must eventually take place to provide compelling performance evidence before adopting full implementation. Testing using full-scale aircraft produces a high-cost approach that yields high-confidence results but simulation provides a low-risk/low-cost approach with reduced confidence on the results. One possible approach to increase the confidence of the results and simultaneously reduce the risk and the cost is using unmanned sub-scale aircraft in testing new concepts for ATM. This paper presents the simulation results of using unmanned sub-scale aircraft in implementing ATM concepts compared to the full scale aircraft. The results of simulation show that the performance of sub-scale is quite comparable to that of the full-scale which validates use of the sub-scale in testing new ATM concepts. Keywords: Unmanned
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-02-01
Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with four PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time whenmore » units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. ARIES documented implementation in 18 housing units. Reductions in average air leakage were 16 percent and duct leakage reductions averaged 23 percent. Total source energy consumption savings due to implemented measures was estimated at 3-10 percent based on BEopt modeling with a simple payback of 1.6 to 2.5 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.« less
Islip Housing Authority Energy Efficiency Turnover Protocols, Islip, New York (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-08-01
More than 1 million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations atmore » the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.« less
Lee, Cheng-Kuang; Pao, Chun-Wei
2016-08-17
Solution-processed small-molecule organic solar cells are a promising renewable energy source because of their low production cost, mechanical flexibility, and light weight relative to their pure inorganic counterparts. In this work, we developed a coarse-grained (CG) Gay-Berne ellipsoid molecular simulation model based on atomistic trajectories from all-atom molecular dynamics simulations of smaller system sizes to systematically study the nanomorphology of the SMDPPEH/PCBM/solvent ternary blend during solution processing, including the blade-coating process by applying external shear to the solution. With the significantly reduced overall system degrees of freedom and computational acceleration from GPU, we were able to go well beyond the limitation of conventional all-atom molecular simulations with a system size on the order of hundreds of nanometers with mesoscale molecular detail. Our simulations indicate that, similar to polymer solar cells, the optimal blending ratio in small-molecule organic solar cells must provide the highest specific interfacial area for efficient exciton dissociation, while retaining balanced hole/electron transport pathway percolation. We also reveal that blade-coating processes have a significant impact on nanomorphology. For given donor/acceptor blending ratios, applying an external shear force can effectively promote donor/acceptor phase segregation and stacking in the SMDPPEH domains. The present study demonstrated the capability of an ellipsoid-based coarse-grained model for studying the nanomorphology evolution of small-molecule organic solar cells during solution processing/blade-coating and provided links between fabrication protocols and device nanomorphologies.
Ter Wee, Marieke M; Coupé, Veerle Mh; den Uyl, Debby; Blomjous, Birgit S; Kooijmans, Esmee; Kerstens, Pit Jsm; Nurmohamed, Mike T; van Schaardenburg, Dirkjan; Voskuyl, Alexandre E; Boers, Maarten; Lems, Willem F
2017-01-01
To evaluate if COmbinatie therapie Bij Reumatoïde Artritis (COBRA)-light therapy is cost-effective in treating patients with early rheumatoid arthritis (RA) compared with COBRA therapy. This economic evaluation was performed next to the open-label, randomised non-inferiority COBRA-light trial in 164 patients with early RA. Non-responders to COBRA or COBRA-light received etanercept (50 mg/week) for 3-6 months. The societal perspective analysis took medical direct, non-medical direct and indirect costs into account. Costs were measured with patient cost diaries for the follow-up period of 52 weeks. Bootstrapping techniques estimated uncertainty around the cost-effectiveness ratios, presented in cost-effectiveness planes. 164 patients were randomised to either COBRA or COBRA-light strategy. At week 52, COBRA-light proved to be non-inferior to COBRA therapy on all clinical outcome measures. The results of the base-case cost-utility analysis (intention-to-treat analyses) revealed that COBRA-light strategy is more expensive (k€9.3 (SD 0.9) compared with COBRA (k€7.2 (SD 0.8)), but the difference in costs were not significant (k€2.0; 95% CI -0.3 to 4.4). Also, both strategies produced similar quality-adjusted life-years (QALYs). The sensitivity analyses showed robustness of these results. In a per-protocol sensitivity analysis, in which costs of etanercept were assumed to be provided as prescribed according to protocol, both arms had much higher costs: COBRA-light: k€11.5 (8.3) compared with k€8.5 (6.8) for COBRA, and the difference in costs was significant (k€2.9; 0.6 to 5.3). In the base-case cost-utility analysis, the two strategies produced similar QALYs for similar costs. But it is anticipated that if protocol had been followed correctly, the COBRA-light strategy would have been more costly due to additional etanercept costs, for a limited health gain. Given the limited added benefit and high costs of starting etanercept in the presence of low disease activity in our trial, such a strategy needs better justification than is available now. 55552928, Results.
Pinkerton, Steven D.; Pearson, Cynthia R.; Eachus, Susan R.; Berg, Karina M.; Grimes, Richard M.
2008-01-01
Summary Maximizing our economic investment in HIV prevention requires balancing the costs of candidate interventions against their effects and selecting the most cost-effective interventions for implementation. However, many HIV prevention intervention trials do not collect cost information, and those that do use a variety of cost data collection methods and analysis techniques. Standardized cost data collection procedures, instrumentation, and analysis techniques are needed to facilitate the task of assessing intervention costs and to ensure comparability across intervention trials. This article describes the basic elements of a standardized cost data collection and analysis protocol and outlines a computer-based approach to implementing this protocol. Ultimately, the development of such a protocol would require contributions and “buy-in” from a diverse range of stakeholders, including HIV prevention researchers, cost-effectiveness analysts, community collaborators, public health decision makers, and funding agencies. PMID:18301128
Adaptive transmission based on multi-relay selection and rate-compatible LDPC codes
NASA Astrophysics Data System (ADS)
Su, Hualing; He, Yucheng; Zhou, Lin
2017-08-01
In order to adapt to the dynamical changeable channel condition and improve the transmissive reliability of the system, a cooperation system of rate-compatible low density parity check (RC-LDPC) codes combining with multi-relay selection protocol is proposed. In traditional relay selection protocol, only the channel state information (CSI) of source-relay and the CSI of relay-destination has been considered. The multi-relay selection protocol proposed by this paper takes the CSI between relays into extra account in order to obtain more chances of collabration. Additionally, the idea of hybrid automatic request retransmission (HARQ) and rate-compatible are introduced. Simulation results show that the transmissive reliability of the system can be significantly improved by the proposed protocol.
NASA Astrophysics Data System (ADS)
Jin, Yi; Zhai, Chao; Gu, Yonggang; Zhou, Zengxiang; Gai, Xiaofeng
2010-07-01
4,000 fiber positioning units need to be positioned precisely in LAMOST(Large Sky Area Multi-object Optical Spectroscopic Telescope) optical fiber positioning & control system, and every fiber positioning unit needs two stepper motors for its driven, so 8,000 stepper motors need to be controlled in the entire system. Wireless communication mode is adopted to save the installing space on the back of the focal panel, and can save more than 95% external wires compared to the traditional cable control mode. This paper studies how to use the ZigBee technology to group these 8000 nodes, explores the pros and cons of star network and tree network in order to search the stars quickly and efficiently. ZigBee technology is a short distance, low-complexity, low power, low data rate, low-cost two-way wireless communication technology based on the IEEE 802.15.4 protocol. It based on standard Open Systems Interconnection (OSI): The 802.15.4 standard specifies the lower protocol layers-the physical layer (PHY), and the media access control (MAC). ZigBee Alliance defined on this basis, the rest layers such as the network layer and application layer, and is responsible for high-level applications, testing and marketing. The network layer used here, based on ad hoc network protocols, includes the following functions: construction and maintenance of the topological structure, nomenclature and associated businesses which involves addressing, routing and security and a self-organizing-self-maintenance functions which will minimize consumer spending and maintenance costs. In this paper, freescale's 802.15.4 protocol was used to configure the network layer. A star network and a tree network topology is realized, which can build network, maintenance network and create a routing function automatically. A concise tree network address allocate algorithm is present to assign the network ID automatically.
Del-Valle-Soto, Carolina; Mex-Perera, Carlos; Orozco-Lugo, Aldo; Lara, Mauricio; Galván-Tejada, Giselle M; Olmedo, Oscar
2014-12-02
Wireless Sensor Networks deliver valuable information for long periods, then it is desirable to have optimum performance, reduced delays, low overhead, and reliable delivery of information. In this work, proposed metrics that influence energy consumption are used for a performance comparison among our proposed routing protocol, called Multi-Parent Hierarchical (MPH), the well-known protocols for sensor networks, Ad hoc On-Demand Distance Vector (AODV), Dynamic Source Routing (DSR), and Zigbee Tree Routing (ZTR), all of them working with the IEEE 802.15.4 MAC layer. Results show how some communication metrics affect performance, throughput, reliability and energy consumption. It can be concluded that MPH is an efficient protocol since it reaches the best performance against the other three protocols under evaluation, such as 19.3% reduction of packet retransmissions, 26.9% decrease of overhead, and 41.2% improvement on the capacity of the protocol for recovering the topology from failures with respect to AODV protocol. We implemented and tested MPH in a real network of 99 nodes during ten days and analyzed parameters as number of hops, connectivity and delay, in order to validate our Sensors 2014, 14 22812 simulator and obtain reliable results. Moreover, an energy model of CC2530 chip is proposed and used for simulations of the four aforementioned protocols, showing that MPH has 15.9% reduction of energy consumption with respect to AODV, 13.7% versus DSR, and 5% against ZTR.
Ambulation During Periods of Supersaturation Increase Decompression Stress in Spacewalk Simulations
NASA Technical Reports Server (NTRS)
Pollock, N. W.; Natoli, M. J.; Martina, S. D.; Conkin, J.; Wessel, J. H., III; Gernhardt, M. L.
2016-01-01
Musculoskeletal activity accelerates inert gas elimination during oxygen breathing prior to decompression (prebreathe), but may also promote bubble formation (nucleation) and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity and the level of tissue supersaturation are likely critical to the net effect. Understanding the relationships is important to evaluate exercise prebreathe protocols and quantify decompression risk in gravity and microgravity environments. The NASA Prebreathe Reduction Program (PRP) combined oxygen prebreathe and exercise preceding a low pressure (4.3 psia; altitude equivalent of 30,300 ft [9,235 m]) simulation exposure of non-ambulatory subjects (a microgravity analog) to produce two protocols now used by astronauts preparing for extravehicular activity. One protocol included both upright cycling and non-cycling exercise (CEVIS: 'cycle ergometer vibration isolation system') and one protocol relied on non-cycling exercise only (ISLE: 'in-suit light exercise'). CEVIS trial data serve as control data for the current study to investigate the influence of ambulation exercise in 1G environments on bubble formation and the subsequent risk of DCS.
NASA Astrophysics Data System (ADS)
Xu, Chong-Yao; Zheng, Xin; Xiong, Xiao-Ming
2017-02-01
With the development of Internet of Things (IoT) and the popularity of intelligent mobile terminals, smart home system has come into people’s vision. However, due to the high cost, complex installation and inconvenience, as well as network security issues, smart home system has not been popularized. In this paper, combined with Wi-Fi technology, Android system, cloud server and SSL security protocol, a new set of smart home system is designed, with low cost, easy operation, high security and stability. The system consists of Wi-Fi smart node (WSN), Android client and cloud server. In order to reduce system cost and complexity of the installation, each Wi-Fi transceiver, appliance control logic and data conversion in the WSN is setup by a single chip. In addition, all the data of the WSN can be uploaded to the server through the home router, without having to transit through the gateway. All the appliance status information and environmental information are preserved in the cloud server. Furthermore, to ensure the security of information, the Secure Sockets Layer (SSL) protocol is used in the WSN communication with the server. What’s more, to improve the comfort and simplify the operation, Android client is designed with room pattern to control home appliances more realistic, and more convenient.
Audio/ Videoconferencing Packages: Low Cost
ERIC Educational Resources Information Center
Treblay, Remy; Fyvie, Barb; Koritko, Brenda
2005-01-01
A comparison was conducted of "Voxwire MeetingRoom" and "iVocalize" v4.1.0.3, both Web-conferencing products using voice-over-Internet protocol (VoIP) to provide unlimited, inexpensive, international audio communication, and high-quality Web-conferencing fostering collaborative learning. The study used the evaluation criteria used in earlier…
A Secure Region-Based Geographic Routing Protocol (SRBGR) for Wireless Sensor Networks
Adnan, Ali Idarous; Hanapi, Zurina Mohd; Othman, Mohamed; Zukarnain, Zuriati Ahmad
2017-01-01
Due to the lack of dependency for routing initiation and an inadequate allocated sextant on responding messages, the secure geographic routing protocols for Wireless Sensor Networks (WSNs) have attracted considerable attention. However, the existing protocols are more likely to drop packets when legitimate nodes fail to respond to the routing initiation messages while attackers in the allocated sextant manage to respond. Furthermore, these protocols are designed with inefficient collection window and inadequate verification criteria which may lead to a high number of attacker selections. To prevent the failure to find an appropriate relay node and undesirable packet retransmission, this paper presents Secure Region-Based Geographic Routing Protocol (SRBGR) to increase the probability of selecting the appropriate relay node. By extending the allocated sextant and applying different message contention priorities more legitimate nodes can be admitted in the routing process. Moreover, the paper also proposed the bound collection window for a sufficient collection time and verification cost for both attacker identification and isolation. Extensive simulation experiments have been performed to evaluate the performance of the proposed protocol in comparison with other existing protocols. The results demonstrate that SRBGR increases network performance in terms of the packet delivery ratio and isolates attacks such as Sybil and Black hole. PMID:28121992
A Secure Region-Based Geographic Routing Protocol (SRBGR) for Wireless Sensor Networks.
Adnan, Ali Idarous; Hanapi, Zurina Mohd; Othman, Mohamed; Zukarnain, Zuriati Ahmad
2017-01-01
Due to the lack of dependency for routing initiation and an inadequate allocated sextant on responding messages, the secure geographic routing protocols for Wireless Sensor Networks (WSNs) have attracted considerable attention. However, the existing protocols are more likely to drop packets when legitimate nodes fail to respond to the routing initiation messages while attackers in the allocated sextant manage to respond. Furthermore, these protocols are designed with inefficient collection window and inadequate verification criteria which may lead to a high number of attacker selections. To prevent the failure to find an appropriate relay node and undesirable packet retransmission, this paper presents Secure Region-Based Geographic Routing Protocol (SRBGR) to increase the probability of selecting the appropriate relay node. By extending the allocated sextant and applying different message contention priorities more legitimate nodes can be admitted in the routing process. Moreover, the paper also proposed the bound collection window for a sufficient collection time and verification cost for both attacker identification and isolation. Extensive simulation experiments have been performed to evaluate the performance of the proposed protocol in comparison with other existing protocols. The results demonstrate that SRBGR increases network performance in terms of the packet delivery ratio and isolates attacks such as Sybil and Black hole.
Capella, Juan V.; Perles, Angel; Bonastre, Alberto; Serrano, Juan J.
2011-01-01
We present a set of novel low power wireless sensor nodes designed for monitoring wooden masterpieces and historical buildings, in order to perform an early detection of pests. Although our previous star-based system configuration has been in operation for more than 13 years, it does not scale well for sensorization of large buildings or when deploying hundreds of nodes. In this paper we demonstrate the feasibility of a cluster-based dynamic-tree hierarchical Wireless Sensor Network (WSN) architecture where realistic assumptions of radio frequency data transmission are applied to cluster construction, and a mix of heterogeneous nodes are used to minimize economic cost of the whole system and maximize power saving of the leaf nodes. Simulation results show that the specialization of a fraction of the nodes by providing better antennas and some energy harvesting techniques can dramatically extend the life of the entire WSN and reduce the cost of the whole system. A demonstration of the proposed architecture with a new routing protocol and applied to termite pest detection has been implemented on a set of new nodes and should last for about 10 years, but it provides better scalability, reliability and deployment properties. PMID:22346630
Capella, Juan V; Perles, Angel; Bonastre, Alberto; Serrano, Juan J
2011-01-01
We present a set of novel low power wireless sensor nodes designed for monitoring wooden masterpieces and historical buildings, in order to perform an early detection of pests. Although our previous star-based system configuration has been in operation for more than 13 years, it does not scale well for sensorization of large buildings or when deploying hundreds of nodes. In this paper we demonstrate the feasibility of a cluster-based dynamic-tree hierarchical Wireless Sensor Network (WSN) architecture where realistic assumptions of radio frequency data transmission are applied to cluster construction, and a mix of heterogeneous nodes are used to minimize economic cost of the whole system and maximize power saving of the leaf nodes. Simulation results show that the specialization of a fraction of the nodes by providing better antennas and some energy harvesting techniques can dramatically extend the life of the entire WSN and reduce the cost of the whole system. A demonstration of the proposed architecture with a new routing protocol and applied to termite pest detection has been implemented on a set of new nodes and should last for about 10 years, but it provides better scalability, reliability and deployment properties.
Enhanced Security and Pairing-free Handover Authentication Scheme for Mobile Wireless Networks
NASA Astrophysics Data System (ADS)
Chen, Rui; Shu, Guangqiang; Chen, Peng; Zhang, Lijun
2017-10-01
With the widely deployment of mobile wireless networks, we aim to propose a secure and seamless handover authentication scheme that allows users to roam freely in wireless networks without worrying about security and privacy issues. Given the open characteristic of wireless networks, safety and efficiency should be considered seriously. Several previous protocols are designed based on a bilinear pairing mapping, which is time-consuming and inefficient work, as well as unsuitable for practical situations. To address these issues, we designed a new pairing-free handover authentication scheme for mobile wireless networks. This scheme is an effective improvement of the protocol by Xu et al., which is suffer from the mobile node impersonation attack. Security analysis and simulation experiment indicate that the proposed protocol has many excellent security properties when compared with other recent similar handover schemes, such as mutual authentication and resistance to known network threats, as well as requiring lower computation and communication cost.
Microgravity Materials and Biotechnology Experiments
NASA Technical Reports Server (NTRS)
Vlasse, Marcus
1998-01-01
Presentation will deal with an overview of the Materials Science and Biotechnology/Crystal Growth flight experiments and their requirements for a successful execution. It will also deal with the hardware necessary to perform these experiments as well as the hardware requirements. This information will serve as a basis for the Abstract: workshop participants to review the poss7ibilifies for a low cost unmanned carrier and the simple automation to carry-out experiments in a microgravity environment with little intervention from the ground. The discussion will include what we have now and what will be needed to automate totally the hardware and experiment protocol at relatively low cost.
Carlos, Fernando; Clark, Patricia; Maciel, Humberto; Tamayo, Juan A
2009-01-01
To compare costs of diagnosis and annual treatment of osteoporosis and hip fracture between the Instituto Nacional de Rehabilitación (INR) and the protocol used by the Seguro Popular de Salud (SPSS). Direct costs gathered in a prospective study with real cases at the INR are presented, and then this data is re-analyzed with the methodology and protocol for the SPSS to estimate the costs of those cases if treated with the SPSS protocol. Important differences were found in the cost of hip fracture: the SPSS estimates ($37,363.73 MXN) almost double the INR cost ($20,286.86 MXN ). This discrepancy was caused by the different types of surgeries the INR and SPSS protocols call for (the SPSS assumes that all hip fractures will necessitate a hip replacement) and the cost of subsequent hospitalization. A prospective study at the SPSS is needed to validate these results. Important differences were found between treatment of the same osteoporosis related problems at the INR and SPSS. We recommend revising the SPSS protocol to include less costly surgical treatments.
Validation of a low dose simulation technique for computed tomography images.
Muenzel, Daniela; Koehler, Thomas; Brown, Kevin; Zabić, Stanislav; Fingerle, Alexander A; Waldt, Simone; Bendik, Edgar; Zahel, Tina; Schneider, Armin; Dobritz, Martin; Rummeny, Ernst J; Noël, Peter B
2014-01-01
Evaluation of a new software tool for generation of simulated low-dose computed tomography (CT) images from an original higher dose scan. Original CT scan data (100 mAs, 80 mAs, 60 mAs, 40 mAs, 20 mAs, 10 mAs; 100 kV) of a swine were acquired (approved by the regional governmental commission for animal protection). Simulations of CT acquisition with a lower dose (simulated 10-80 mAs) were calculated using a low-dose simulation algorithm. The simulations were compared to the originals of the same dose level with regard to density values and image noise. Four radiologists assessed the realistic visual appearance of the simulated images. Image characteristics of simulated low dose scans were similar to the originals. Mean overall discrepancy of image noise and CT values was -1.2% (range -9% to 3.2%) and -0.2% (range -8.2% to 3.2%), respectively, p>0.05. Confidence intervals of discrepancies ranged between 0.9-10.2 HU (noise) and 1.9-13.4 HU (CT values), without significant differences (p>0.05). Subjective observer evaluation of image appearance showed no visually detectable difference. Simulated low dose images showed excellent agreement with the originals concerning image noise, CT density values, and subjective assessment of the visual appearance of the simulated images. An authentic low-dose simulation opens up opportunity with regard to staff education, protocol optimization and introduction of new techniques.
NASA Astrophysics Data System (ADS)
Roesler, E. L.; Bosler, P. A.; Taylor, M.
2016-12-01
The impact of strong extratropical storms on coastal communities is large, and the extent to which storms will change with a warming Arctic is unknown. Understanding storms in reanalysis and in climate models is important for future predictions. We know that the number of detected Arctic storms in reanalysis is sensitive to grid resolution. To understand Arctic storm sensitivity to resolution in climate models, we describe simulations designed to identify and compare Arctic storms at uniform low resolution (1 degree), at uniform high resolution (1/8 degree), and at variable resolution (1 degree to 1/8 degree). High-resolution simulations resolve more fine-scale structure and extremes, such as storms, in the atmosphere than a uniform low-resolution simulation. However, the computational cost of running a globally uniform high-resolution simulation is often prohibitive. The variable resolution tool in atmospheric general circulation models permits regional high-resolution solutions at a fraction of the computational cost. The storms are identified using the open-source search algorithm, Stride Search. The uniform high-resolution simulation has over 50% more storms than the uniform low-resolution and over 25% more storms than the variable resolution simulations. Storm statistics from each of the simulations is presented and compared with reanalysis. We propose variable resolution as a cost-effective means of investigating physics/dynamics coupling in the Arctic environment. Future work will include comparisons with observed storms to investigate tuning parameters for high resolution models. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. SAND2016-7402 A
Low-power, low-cost urinalysis system with integrated dipstick evaluation and microscopic analysis.
Smith, Gennifer T; Li, Linkai; Zhu, Yue; Bowden, Audrey K
2018-06-21
We introduce a coupled dipstick and microscopy device for analyzing urine samples. The device is capable of accurately assessing urine dipstick results while simultaneously imaging the microscopic contents within the sample. We introduce a long working distance, cellphone-based microscope in combination with an oblique illumination scheme to accurately visualize and quantify particles within the urine sample. To facilitate accurate quantification, we couple the imaging set-up with a power-free filtration system. The proposed device is reusable, low-cost, and requires very little power. We show that results obtained with the proposed device and custom-built app are consistent with those obtained with the standard clinical protocol, suggesting the potential clinical utility of the device.
Rapid Quantification of Abscisic Acid by GC-MS/MS for Studies of Abiotic Stress Response.
Verslues, Paul E
2017-01-01
Drought and low water potential induce large increases in Abscisic Acid (ABA ) content of plant tissue. This increased ABA content is essential to regulate downstream stress resistance responses; however, the mechanisms regulating ABA accumulation are incompletely known. Thus, the ability to accurately quantify ABA at high throughput and low cost is important for plant stress research. We have combined and modified several previously published protocols to establish a rapid ABA analysis protocol using gas chromatography-tandem mass spectrometry (GC-MS/MS). Derivatization of ABA is performed with (trimethylsilyl)-diazomethane rather than the harder to prepare diazomethane. Sensitivity of the analysis is sufficient that small samples of low water potential treated Arabidopsis thaliana seedlings can be routinely analyzed in reverse genetic studies of putative stress regulators as well as studies of natural variation in ABA accumulation.
Gaudio, Carlo; Petriello, Gennaro; Pelliccia, Francesco; Tanzilli, Alessandra; Bandiera, Alberto; Tanzilli, Gaetano; Barillà, Francesco; Paravati, Vincenzo; Pellegrini, Massimo; Mangieri, Enrico; Barillari, Paolo
2018-05-08
Cardiac computed tomography (CT) is often performed in patients who are at high risk for lung cancer in whom screening is currently recommended. We tested diagnostic ability and radiation exposure of a novel ultra-low-dose CT protocol that allows concomitant coronary artery evaluation and lung screening. We studied 30 current or former heavy smoker subjects with suspected or known coronary artery disease who underwent CT assessment of both coronary arteries and thoracic area (Revolution CT, General Electric). A new ultrafast-low-dose single protocol was used for ECG-gated helical acquisition of the heart and the whole chest. A single IV iodine bolus (70-90 ml) was used. All patients with CT evidence of coronary stenosis underwent also invasive coronary angiography. All the coronary segments were assessable in 28/30 (93%) patients. Only 8 coronary segments were not assessable in 2 patients due to motion artefacts (assessability: 98%; 477/485 segments). In the assessable segments, 20/21 significant stenoses (> 70% reduction of vessel diameter) were correctly diagnosed. Pulmonary nodules were detected in 5 patients, thus requiring to schedule follow-up surveillance CT thorax. Effective dose was 1.3 ± 0.9 mSv (range: 0.8-3.2 mSv). Noteworthy, no contrast or radiation dose increment was required with the new protocol as compared to conventional coronary CT protocol. The novel ultrafast-low-dose CT protocol allows lung cancer screening at time of coronary artery evaluation. The new approach might enhance the cost-effectiveness of coronary CT in heavy smokers with suspected or known coronary artery disease.
Prototype Common Bus Spacecraft: Hover Test Implementation and Results. Revision, Feb. 26, 2009
NASA Technical Reports Server (NTRS)
Hine, Butler Preston; Turner, Mark; Marshall, William S.
2009-01-01
In order to develop the capability to evaluate control system technologies, NASA Ames Research Center (Ames) began a test program to build a Hover Test Vehicle (HTV) - a ground-based simulated flight vehicle. The HTV would integrate simulated propulsion, avionics, and sensors into a simulated flight structure, and fly that test vehicle in terrestrial conditions intended to simulate a flight environment, in particular for attitude control. The ultimate purpose of the effort at Ames is to determine whether the low-cost hardware and flight software techniques are viable for future low cost missions. To enable these engineering goals, the project sought to develop a team, processes and procedures capable of developing, building and operating a fully functioning vehicle including propulsion, GN&C, structure, power and diagnostic sub-systems, through the development of the simulated vehicle.
Serra, M; Pereiro, I; Yamada, A; Viovy, J-L; Descroix, S; Ferraro, D
2017-02-14
The sealing of microfluidic devices remains a complex and time-consuming process requiring specific equipment and protocols: a universal method is thus highly desirable. We propose here the use of a commercially available sealing tape as a robust, versatile, reversible solution, compatible with cell and molecular biology protocols, and requiring only the application of manually achievable pressures. The performance of the seal was tested with regards to the most commonly used chip materials. For most materials, the bonding resisted 5 bars at room temperature and 1 bar at 95 °C. This method should find numerous uses, ranging from fast prototyping in the laboratory to implementation in low technology environments or industrial production.
A flexible acquisition cycle for incompletely defined fieldbus protocols.
Gaitan, Vasile-Gheorghita; Gaitan, Nicoleta-Cristina; Ungurean, Ioan
2014-05-01
Real time data-acquisition from fieldbuses strongly depends on the network type and protocol used. Currently, there is an impressive number of fieldbuses, some of them are completely defined and others are incompletely defined. In those from the second category, the time variable, the main element in real-time data acquisition, does not appear explicitly. Examples include protocols such as Modbus ASCII/RTU, M-bus, ASCII character-based, and so on. This paper defines a flexible acquisition cycle based on the Master-Slave architecture that can be implemented on a Master station, called a Base Station Gateway (BSG). The BSG can add a timestamp for temporal location of data. It also presents a possible extension for the Modbus protocol, developed as simple and low cost solution based on existing hardware. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
Rapid Waterborne Pathogen Detection with Mobile Electronics.
Wu, Tsung-Feng; Chen, Yu-Chen; Wang, Wei-Chung; Kucknoor, Ashwini S; Lin, Che-Jen; Lo, Yu-Hwa; Yao, Chun-Wei; Lian, Ian
2017-06-09
Pathogen detection in water samples, without complex and time consuming procedures such as fluorescent-labeling or culture-based incubation, is essential to public safety. We propose an immunoagglutination-based protocol together with the microfluidic device to quantify pathogen levels directly from water samples. Utilizing ubiquitous complementary metal-oxide-semiconductor (CMOS) imagers from mobile electronics, a low-cost and one-step reaction detection protocol is developed to enable field detection for waterborne pathogens. 10 mL of pathogen-containing water samples was processed using the developed protocol including filtration enrichment, immune-reaction detection and imaging processing. The limit of detection of 10 E. coli O157:H7 cells/10 mL has been demonstrated within 10 min of turnaround time. The protocol can readily be integrated into a mobile electronics such as smartphones for rapid and reproducible field detection of waterborne pathogens.
FISH-in-CHIPS: A Microfluidic Platform for Molecular Typing of Cancer Cells.
Perez-Toralla, Karla; Mottet, Guillaume; Tulukcuoglu-Guneri, Ezgi; Champ, Jérôme; Bidard, François-Clément; Pierga, Jean-Yves; Klijanienko, Jerzy; Draskovic, Irena; Malaquin, Laurent; Viovy, Jean-Louis; Descroix, Stéphanie
2017-01-01
Microfluidics offer powerful tools for the control, manipulation, and analysis of cells, in particular for the assessment of cell malignancy or the study of cell subpopulations. However, implementing complex biological protocols on chip remains a challenge. Sample preparation is often performed off chip using multiple manually performed steps, and protocols usually include different dehydration and drying steps that are not always compatible with a microfluidic format.Here, we report the implementation of a Fluorescence in situ Hybridization (FISH) protocol for the molecular typing of cancer cells in a simple and low-cost device. The geometry of the chip allows integrating the sample preparation steps to efficiently assess the genomic content of individual cells using a minute amount of sample. The FISH protocol can be fully automated, thus enabling its use in routine clinical practice.
Tan, K. E.; Ellis, B. C.; Lee, R.; Stamper, P. D.; Zhang, S. X.
2012-01-01
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories. PMID:22855510
Tan, K E; Ellis, B C; Lee, R; Stamper, P D; Zhang, S X; Carroll, K C
2012-10-01
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories.
Aminde, Leopold Ndemnge; Veerman, Lennert
2016-12-21
Low-income and middle-income countries (LMICs) are experiencing a growing disease burden due to cardiovascular and other chronic non-communicable diseases. Interventions for the control of these diseases are paramount; however, these countries are faced with competing health and financial needs. There is an urgent need for quality evidence on cost-effective strategies to address these chronic diseases. We aim to synthesise the current literature on economic evaluations of interventions for primary and secondary cardiovascular disease prevention in LMICs. A systematic review of studies (published and unpublished) in LMICs up to 30 October 2016 will be conducted. The following databases will be searched: PubMed/MEDLINE, EMBASE, SCOPUS, CINAHL, Web of Science, EconLit, NHS Economic Evaluations Database (NHS EED). Data sources specific to African literature, such as the WHO AFROLIB, Africa Index Medicus and African Journals online (AJOL) as well as grey literature, will also be searched. 2 reviewers shall independently screen potential articles for inclusion and disagreements shall be resolved by consensus. Quality appraisal of studies shall be done using Drummond's checklist for economic evaluation of studies. A descriptive synthesis of the evidence obtained is planned. The primary outcomes will be costs per life years gained or unit of clinical outcome, cost per quality-adjusted life years or disability-adjusted life years. This systematic review protocol has been prepared according to the Preferred Reporting Items for Systematic reviews and Meta-analyses for Protocols (PRISMA-P) 2015 statement. Ethics approval is not required considering that this is a protocol for a systematic review of published studies. Results from this review will be disseminated via conference presentations and peer-reviewed journal publications. CRD42016043510. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Design of New Procedures for Diagnosing Prevalent Diseases Using a Low-Cost Telemicroscopy System.
Prieto-Egido, Ignacio; González-Escalada, Alba; García-Giganto, Víctor; Martínez-Fernández, Andrés
2016-11-01
Currently, the diagnosis of prevalent diseases such as malaria, tuberculosis, or diarrheal diseases in rural areas of developing countries requires the displacement of the patient from their community health post to their reference health center or to ship a sample. This delays diagnosis and the treatment of disease. Conduct research to develop a new method for rapid low-cost diagnosis of prevalent diseases in rural areas of developing countries (malaria, tuberculosis, parasitic infections, vaginal infections, and cervical cancer). The study was divided into three phases. The first related to the drafting and validating of new protocols for the preparation of samples that should be adapted to be carried out in areas without power and with little trained personnel. The second phase consisted of developing a telemicroscopy system looking for low cost, software compatibility, and technical quality. Finally, the third phase evaluated the system as a diagnostic tool using direct observation with a conventional microscope as the gold standard. The validation of the new protocols showed that 100% of the vaginal swabs were processed correctly when using direct smear, while they were only 86.3% correct when using Gram stain; 68.3% of fecal samples were correctly processed using Kinyoun stain; 61.7% of blood samples when using thin film; and 83.8% when using thick film. Phase 2 permitted the development of a low-cost (<$250) and low-power (<15 W) telemicroscopy system that allows real-time consultation between health technicians and specialists. Finally, phase 3 proved that there was no difference between the diagnostics obtained by direct observation in a microscope and those ones obtained through the new telemicroscopy system. This study has verified the effectiveness of the telemicroscopy system as a diagnostic tool, given the complete agreement between the diagnoses made with it and those made with the gold standard.
Costs and inconsistencies in US IRB review of low-risk medical education research.
Kano, Miria; Getrich, Christina M; Romney, Crystal; Sussman, Andrew L; Williams, Robert L
2015-06-01
Advances in communication technologies over the last two decades have transformed the way medical education research is conducted, creating opportunities for multi-institution national and international studies. Although these studies enable researchers to gain broader understandings of educational processes across institutions, they increase the need for multiple institutional review board (IRB) reviews to ensure the protection of human subjects. This study describes the process of obtaining multiple IRB approvals of the same protocol for a multi-site, low-risk, medical education research project in the USA. The burden of obtaining those reviews and their consistency are assessed. The associated time and costs, and implications for the research process are detailed. Following review by the investigators' parent institution IRB, the project team circulated a uniform protocol for conduct of a low-risk, medical education survey to the IRBs of 89 US medical schools for review. The processes and time required to obtain approvals were recorded to estimate associated research team personnel costs. Approval could not be obtained from five IRBs as a result of insurmountable procedural barriers. A total of 67 IRBs eventually deferred to the parent IRB determination. The remaining IRBs required a variety of additional procedural processes before ultimately agreeing with the original determination. The personnel costs associated with obtaining the 84 approvals amounted to US$121,344. Considering the value of multi-site designs to address a range of research questions, enhance participant diversity and develop representative findings, solutions must be found to counter inefficiencies of current IRB review processes for low-risk research, such as that usually conducted in medical education. Although we acknowledge that local review is an essential protective measure for research involving identifiable communities that are uniquely susceptible to social or economic harm, this report suggests that proposals to modernise and streamline IRB review processes for low-risk research are timely and relevant. © 2015 John Wiley & Sons Ltd.
Gu, Dongfeng; He, Jiang; Coxson, Pamela G; Rasmussen, Petra W; Huang, Chen; Thanataveerat, Anusorn; Tzong, Keane Y; Xiong, Juyang; Wang, Miao; Zhao, Dong; Goldman, Lee; Moran, Andrew E
2015-08-01
Hypertension is China's leading cardiovascular disease risk factor. Improved hypertension control in China would result in result in enormous health gains in the world's largest population. A computer simulation model projected the cost-effectiveness of hypertension treatment in Chinese adults, assuming a range of essential medicines list drug costs. The Cardiovascular Disease Policy Model-China, a Markov-style computer simulation model, simulated hypertension screening, essential medicines program implementation, hypertension control program administration, drug treatment and monitoring costs, disease-related costs, and quality-adjusted life years (QALYs) gained by preventing cardiovascular disease or lost because of drug side effects in untreated hypertensive adults aged 35-84 y over 2015-2025. Cost-effectiveness was assessed in cardiovascular disease patients (secondary prevention) and for two blood pressure ranges in primary prevention (stage one, 140-159/90-99 mm Hg; stage two, ≥160/≥100 mm Hg). Treatment of isolated systolic hypertension and combined systolic and diastolic hypertension were modeled as a reduction in systolic blood pressure; treatment of isolated diastolic hypertension was modeled as a reduction in diastolic blood pressure. One-way and probabilistic sensitivity analyses explored ranges of antihypertensive drug effectiveness and costs, monitoring frequency, medication adherence, side effect severity, background hypertension prevalence, antihypertensive medication treatment, case fatality, incidence and prevalence, and cardiovascular disease treatment costs. Median antihypertensive costs from Shanghai and Yunnan province were entered into the model in order to estimate the effects of very low and high drug prices. Incremental cost-effectiveness ratios less than the per capita gross domestic product of China (11,900 international dollars [Int$] in 2015) were considered cost-effective. Treating hypertensive adults with prior cardiovascular disease for secondary prevention was projected to be cost saving in the main simulation and 100% of probabilistic simulation results. Treating all hypertension for primary and secondary prevention would prevent about 800,000 cardiovascular disease events annually (95% uncertainty interval, 0.6 to 1.0 million) and was borderline cost-effective incremental to treating only cardiovascular disease and stage two patients (2015 Int$13,000 per QALY gained [95% uncertainty interval, Int$10,000 to Int$18,000]). Of all one-way sensitivity analyses, assuming adherence to taking medications as low as 25%, high Shanghai drug costs, or low medication efficacy led to the most unfavorable results (treating all hypertension, about Int$47,000, Int$37,000, and Int$27,000 per QALY were gained, respectively). The strengths of this study were the use of a recent Chinese national health survey, vital statistics, health care costs, and cohort study outcomes data as model inputs and reliance on clinical-trial-based estimates of coronary heart disease and stroke risk reduction due to antihypertensive medication treatment. The limitations of the study were the use of several sources of data, limited clinical trial evidence for medication effectiveness and harms in the youngest and oldest age groups, lack of information about geographic and ethnic subgroups, lack of specific information about indirect costs borne by patients, and uncertainty about the future epidemiology of cardiovascular diseases in China. Expanded hypertension treatment has the potential to prevent about 800,000 cardiovascular disease events annually and be borderline cost-effective in China, provided low-cost essential antihypertensive medicines programs can be implemented.
Fast-track surgery for uncomplicated appendicitis in children: a matched case-control study.
Cundy, Thomas P; Sierakowski, Kyra; Manna, Alexandra; Cooper, Celia M; Burgoyne, Laura L; Khurana, Sanjeev
2017-04-01
Standardized post-operative protocols reduce variation and enhance efficiency in patient care. Patients may benefit from these initiatives by improved quality of care. This matched case-control study investigates the effect of a multidisciplinary criteria-led discharge protocol for uncomplicated appendicitis in children. Key protocol components included limiting post-operative antibiotics to two intravenous doses, avoidance of intravenous opioid analgesia, prompt resumption of diet, active encouragement of early ambulation and nursing staff autonomy to discharge patients that met assigned criteria. The study period was from August 2015 to February 2016. Outcomes were compared with a historical control group matched for operative approach. Outcomes for 83 patients enrolled to our protocol were compared with those of 83 controls. There was a 29.2% reduction in median post-operative length of stay in our protocol-based care group (19.6 versus 27.7 h; P < 0.001). The rate of discharges within 24 h improved from 12 to 42%. There was no significant difference in complication rate (4.8 versus 7.2%; P = 0.51). Mean oral morphine dose equivalent per kilogram requirement was less than half (46%) that of control group patients (P < 0.001). Mean number of ondansetron doses was also significantly lower. Projected annual direct cost savings following protocol implementation was AUD$77 057. Implementation of a criteria-led discharge protocol at our hospital decreased length of stay, reduced variation in care, preserved existing low morbidity, incurred substantial cost savings, and safely rationalized opioid and antiemetic medication. These protocols are inexpensive and offer tangible benefits that are accessible to all health care settings. © 2016 Royal Australasian College of Surgeons.
Economic and Environmental Impacts of Harmful Non-Indigenous Species in Southeast Asia
Nghiem, Le T. P.; Soliman, Tarek; Yeo, Darren C. J.; Tan, Hugh T. W.; Evans, Theodore A.; Mumford, John D.; Keller, Reuben P.; Baker, Richard H. A.; Corlett, Richard T.; Carrasco, Luis R.
2013-01-01
Harmful non-indigenous species (NIS) impose great economic and environmental impacts globally, but little is known about their impacts in Southeast Asia. Lack of knowledge of the magnitude of the problem hinders the allocation of appropriate resources for NIS prevention and management. We used benefit-cost analysis embedded in a Monte-Carlo simulation model and analysed economic and environmental impacts of NIS in the region to estimate the total burden of NIS in Southeast Asia. The total annual loss caused by NIS to agriculture, human health and the environment in Southeast Asia is estimated to be US$33.5 billion (5th and 95th percentile US$25.8–39.8 billion). Losses and costs to the agricultural sector are estimated to be nearly 90% of the total (US$23.4–33.9 billion), while the annual costs associated with human health and the environment are US$1.85 billion (US$1.4–2.5 billion) and US$2.1 billion (US$0.9–3.3 billion), respectively, although these estimates are based on conservative assumptions. We demonstrate that the economic and environmental impacts of NIS in low and middle-income regions can be considerable and that further measures, such as the adoption of regional risk assessment protocols to inform decisions on prevention and control of NIS in Southeast Asia, could be beneficial. PMID:23951120
When Is Rapid On-Site Evaluation Cost-Effective for Fine-Needle Aspiration Biopsy?
Schmidt, Robert L.; Walker, Brandon S.; Cohen, Michael B.
2015-01-01
Background Rapid on-site evaluation (ROSE) can improve adequacy rates of fine-needle aspiration biopsy (FNAB) but increases operational costs. The performance of ROSE relative to fixed sampling depends on many factors. It is not clear when ROSE is less costly than sampling with a fixed number of needle passes. The objective of this study was to determine the conditions under which ROSE is less costly than fixed sampling. Methods Cost comparison of sampling with and without ROSE using mathematical modeling. Models were based on a societal perspective and used a mechanistic, micro-costing approach. Sampling policies (ROSE, fixed) were compared using the difference in total expected costs per case. Scenarios were based on procedure complexity (palpation-guided or image-guided), adequacy rates (low, high) and sampling protocols (stopping criteria for ROSE and fixed sampling). One-way, probabilistic, and scenario-based sensitivity analysis was performed to determine which variables had the greatest influence on the cost difference. Results ROSE is favored relative to fixed sampling under the following conditions: (1) the cytologist is accurate, (2) the total variable cost ($/hr) is low, (3) fixed costs ($/procedure) are high, (4) the setup time is long, (5) the time between needle passes for ROSE is low, (6) when the per-pass adequacy rate is low, and (7) ROSE stops after observing one adequate sample. The model is most sensitive to variation in the fixed cost, the per-pass adequacy rate, and the time per needle pass with ROSE. Conclusions Mathematical modeling can be used to predict the difference in cost between sampling with and without ROSE. PMID:26317785
Multi-fidelity methods for uncertainty quantification in transport problems
NASA Astrophysics Data System (ADS)
Tartakovsky, G.; Yang, X.; Tartakovsky, A. M.; Barajas-Solano, D. A.; Scheibe, T. D.; Dai, H.; Chen, X.
2016-12-01
We compare several multi-fidelity approaches for uncertainty quantification in flow and transport simulations that have a lower computational cost than the standard Monte Carlo method. The cost reduction is achieved by combining a small number of high-resolution (high-fidelity) simulations with a large number of low-resolution (low-fidelity) simulations. We propose a new method, a re-scaled Multi Level Monte Carlo (rMLMC) method. The rMLMC is based on the idea that the statistics of quantities of interest depends on scale/resolution. We compare rMLMC with existing multi-fidelity methods such as Multi Level Monte Carlo (MLMC) and reduced basis methods and discuss advantages of each approach.
Sunstrom, Rachel; Hamilton, Nicholas; Fialkowski, Elizabeth; Lofberg, Katrine; McKee, Julie; Sims, Thomas; Krishnaswami, Sanjay; Azarow, Kenneth
2016-05-01
A protocol for laparoscopic gastrostomy placement was implemented which specified perioperative antibiotics, feeding regimens, and discharge criteria. Our hypothesis was that hospital cost could be decreased, whereas at the same time improving or maintaining patient outcomes. Data were collected on consecutive patients beginning 6 months after implementation of our protocol. We recorded surgeon compliance, patient outcomes (as defined by 30-day NSQIP complication rates), and cost of initial hospitalization, which was then compare to a 6-month historical control period. Our control group n = 26 and protocol group n = 39. Length of stay was shorter in the protocol group (P ≤ .05 by nonparametric analysis). The complication rate was similar in both groups (23% control vs 15% protocol, P = .43). Initial hospital costs were not different. Surgeon compliance to protocol was 82%. A standard protocol is achievable for gastrostomy tube management. After implementation of our protocol, we were able to show a significant decrease in length of stay, whereas maintaining quality. Copyright © 2016 Elsevier Inc. All rights reserved.
Liao, Pei-Fen; Ku, Min-Sho; Tsai, Jeng-Dau; Choa, Yu-Hua; Hung, Tung-Wei; Lue, Ko-Huang; Sheu, Ji-Nan
2014-09-01
We examined the ability of a procalcitonin (PCT) protocol to detect vesicoureteral reflux (VUR) and renal scarring (RS), evaluated procedural costs and radiation burden, and compared four representative guidelines for children with their first febrile urinary tract infection (UTI). Children aged ≤2 years with their first febrile UTI who underwent renal ultrasonography (US), acute and late technetium-99m ((99m)Tc)-dimercaptosuccinic acid scan, and voiding cystourethrography were prospectively studied. The representative guidelines applied in a retrospective simulation included the American Academy of Pediatrics (AAP), National Institute of Clinical Excellence, top-down approach (TDA), and Italian Society of Pediatric Nephrology (ISPN). These were compared in terms of ability to detect abnormalities, procedural costs and radiation. Of 278 children analyzed, 172 (61.9%) had acute pyelonephritis. There was VUR in 101 (36.3%) children, including 73 (26.3%) with grades III-V VUR. RS was identified in 75 (27.0%) children. To detect VUR, TDA and PCT had the highest sensitivity for grades I-V VUR (80.2%) and III-V VUR (94.5%), respectively, whereas AAP had the highest specificity for I-V VUR (77.4%) and III-V VUR (78.0%), respectively. TDA and PCT had the highest sensitivity (100%) for detecting RS. The highest cost and radiation dose was associated with TDA, whereas AAP had the least expenditure and radiation exposure. By multivariate analysis, PCT and VUR, especially grades III-V, were independent predictors of RS. There is no perfect guideline for first febrile UTI children. The PCT protocol has good ability for detecting high-grade VUR and RS. If based on available imaging modalities and reducing cost and radiation burden, clinical suggestions in the AAP guidelines represent a considerable protocol.
Magee, Michelle F
2007-05-15
Evolving elements of best practices for providing targeted glycemic control in the hospital setting, clinical performance measurement, basal-bolus plus correction-dose insulin regimens, components of standardized subcutaneous (s.c.) insulin order sets, and strategies for implementation and cost justification of glycemic control initiatives are discussed. Best practices for targeted glycemic control should address accurate documentation of hyperglycemia, initial patient assessment, management plan, target blood glucose range, blood glucose monitoring frequency, maintenance of glycemic control, criteria for glucose management consultations, and standardized insulin order sets and protocols. Establishing clinical performance measures, including desirable processes and outcomes, can help ensure the success of targeted hospital glycemic control initiatives. The basal-bolus plus correction-dose regimen for insulin administration will be used to mimic the normal physiologic pattern of endogenous insulin secretion. Standardized insulin order sets and protocols are being used to minimize the risk of error in insulin therapy. Components of standardized s.c. insulin order sets include specification of the hyperglycemia diagnosis, finger stick blood glucose monitoring frequency and timing, target blood glucose concentration range, cutoff values for excessively high or low blood glucose concentrations that warrant alerting the physician, basal and prandial or nutritional (i.e., bolus) insulin, correction doses, hypoglycemia treatment, and perioperative or procedural dosage adjustments. The endorsement of hospital administrators and key physician and nursing leaders is needed for glycemic control initiatives. Initiatives may be cost justified on the basis of the billings for clinical diabetes management services and/or the return- on-investment accrued to reductions in hospital length of stay, readmissions, and accurate documentation and coding of unrecognized or uncontrolled diabetes, and diabetes complications. Standardized insulin order sets and protocols may minimize risk of insulin errors. The endorsement of these protocols by administrators, physicians, nurses, and pharmacists is also needed for success.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kats, G.H.; Rosenfield, A.H.; McIntosh, T.A.
1997-06-01
The energy efficiency industry is constrained by lack of financing. For example, in the United States, commercial and public buildings need an investment of $100 billion for cost-effective retrofits with an average payback of about four years. But the current level of financing is stagnant at only about 34% of this level per year. The U.S. Department of Energy (DOE) has led the development of the North American Energy Measurement and Verification Protocol (NEMVP). This Protocol will increase the reliability and quality of estimated efficiency savings and improve realized savings. A critical element in the development of low cost financingmore » and a secondary market--whether for homes or credit card debt--is the adoption of protocols to provide uniformity and reliability of the product. This is also true of energy efficiency installations, which have been characterized by inconsistency in the installation methodologies and, frequently, unreliability of savings. This Protocol, published in April 1996, is a DOE-led effort involving American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. ASHRAE, National Association of Energy Service Companies NAESCO, National Association of Regulatory Utility Commissioners NARUC, National Association of State Energy Officials NASEO, US Environmental Protection Agency EPA, Canada`s Canadian Association of Energy Service Companies CAESCO, and Mexico`s Comision Nacional Para El Ahorro De Energia CONAE and Fideicomiso De Apoyo Al Programa De Ahorro De Energia Del Sector Electrico FIDE. DOE has begun to build on this Protocol to develop new forms of lower-cost financing including, ultimately, development of a secondary market for energy efficiency. This could double financing for building energy efficiency within five years.« less
ERIC Educational Resources Information Center
Wright, David L.; Magnuson, Curt E.; Black, Charles B.
2005-01-01
Individuals practiced two unique discrete sequence production tasks that differed in their relative time profile in either a blocked or random practice schedule. Each participant was subsequently administered a "precuing" protocol to examine the cost of initially compiling or modifying the plan for an upcoming movement's relative timing. The…
A Low-Cost Thermistor Device for Measurements of Metabolic Heat in Yeast Cells in Suspension.
ERIC Educational Resources Information Center
Keeling, Richard P.
1980-01-01
Provides illustrated directions for the construction and use of a low-cost thermistor device. Attached to a servo-type millivolt chart recorder, the device will record minute temperature changes and will simulate data obtained from an oxygen polarograph. Includes results of experiments with baker's yeast. (Author/CS)
NASA Astrophysics Data System (ADS)
Purohit, Pallav; Hoglund-Isaksson, Lena
2016-04-01
The anthropogenic fluorinated (F-gases) greenhouse gas emissions have increased significantly in recent years and are estimated to rise further in response to increased demand for cooling services and the phase out of ozone-depleting substances (ODS) under the Montreal Protocol. F-gases (HFCs, PFCs and SF6) are potent greenhouse gases, with a global warming effect up to 22,800 times greater than carbon dioxide (CO2). This study presents estimates of current and future global emissions of F-gases, their technical mitigation potential and associated costs for the period 2005 to 2050. The analysis uses the GAINS model framework to estimate emissions, mitigation potentials and costs for all major sources of anthropogenic F-gases for 162 countries/regions, which are aggregated to produce global estimates. For each region, 18 emission source sectors with mitigation potentials and costs were identified. Global F-gas emissions are estimated at 0.7 Gt CO2eq in 2005 with an expected increase to about 3.6 Gt CO2eq in 2050. There are extensive opportunities to reduce emissions by over 95 percent primarily through replacement with existing low GWP substances. The initial results indicate that at least half of the mitigation potential is attainable at a cost of less than 20€ per t CO2eq, while almost 90 percent reduction is attainable at less than 100€ per t CO2eq. Currently, several policy proposals have been presented to amend the Montreal Protocol to substantially curb global HFC use. We analyze the technical potentials and costs associated with the HFC mitigation required under the different proposed Montreal Protocol amendments.
Estimated cost of a health visitor-led protocol for perinatal mental health.
Oluboyede, Yemi; Lewis, Anne; Ilott, Irene; Lekka, Chrysanthi
2010-06-01
Anecdotally, protocols, care pathways and clinical guidelines are time consuming to develop and sustain, but there is little research about the actual costs of their development, use and audit.This is a notable gap considering the pervasiveness of such documents that are intended to reduce unacceptable variations in practice by standardising care processes. A case study research design was used to calculate the resource use costs of a protocol for perinatal mental health, part of the core programme for health visitors in a primary care trust in the west of England. The methods were in-depth interviews with the operational lead for the protocol (a health visitor) and documentary analysis. The total estimated cost of staff time over a five-year period (2004 to 2008) was Euro 73,598, comprising Euro 36,162 (49%) for development and Euro 37,436 (51%) for implementation. Although these are best estimates dependent upon retrospective data, they indicate the opportunity cost of staff time for a single protocol in one trust over five years. When new protocols, care pathways or clinical guidelines are proposed, the costs need to be considered and weighed against the benefits of engaging frontline staff in service improvements.
Representing the work of medical protocols for organizational simulation.
Fridsma, D. B.
1998-01-01
Developing and implementing patient care protocols within a specific organizational setting requires knowledge of the protocol, the organization, and the way in which the organization does its work. Computer-based simulation tools have been used in many industries to provide managers with prospective insight into problems of work process and organization design mismatch. Many of these simulation tools are designed for well-understood routine work processes in which there are few contingent tasks. In this paper, we describe theoretic that make it possible to simulate medical protocols using an information-processing theory framework. These simulations will allow medical administrators to test different protocol and organizational designs before actually using them within a particular clinical setting. PMID:9929231
Privacy-preserving record linkage using Bloom filters
2009-01-01
Background Combining multiple databases with disjunctive or additional information on the same person is occurring increasingly throughout research. If unique identification numbers for these individuals are not available, probabilistic record linkage is used for the identification of matching record pairs. In many applications, identifiers have to be encrypted due to privacy concerns. Methods A new protocol for privacy-preserving record linkage with encrypted identifiers allowing for errors in identifiers has been developed. The protocol is based on Bloom filters on q-grams of identifiers. Results Tests on simulated and actual databases yield linkage results comparable to non-encrypted identifiers and superior to results from phonetic encodings. Conclusion We proposed a protocol for privacy-preserving record linkage with encrypted identifiers allowing for errors in identifiers. Since the protocol can be easily enhanced and has a low computational burden, the protocol might be useful for many applications requiring privacy-preserving record linkage. PMID:19706187
Privacy-preserving record linkage using Bloom filters.
Schnell, Rainer; Bachteler, Tobias; Reiher, Jörg
2009-08-25
Combining multiple databases with disjunctive or additional information on the same person is occurring increasingly throughout research. If unique identification numbers for these individuals are not available, probabilistic record linkage is used for the identification of matching record pairs. In many applications, identifiers have to be encrypted due to privacy concerns. A new protocol for privacy-preserving record linkage with encrypted identifiers allowing for errors in identifiers has been developed. The protocol is based on Bloom filters on q-grams of identifiers. Tests on simulated and actual databases yield linkage results comparable to non-encrypted identifiers and superior to results from phonetic encodings. We proposed a protocol for privacy-preserving record linkage with encrypted identifiers allowing for errors in identifiers. Since the protocol can be easily enhanced and has a low computational burden, the protocol might be useful for many applications requiring privacy-preserving record linkage.
Optimization of the scan protocols for CT-based material extraction in small animal PET/CT studies
NASA Astrophysics Data System (ADS)
Yang, Ching-Ching; Yu, Jhih-An; Yang, Bang-Hung; Wu, Tung-Hsin
2013-12-01
We investigated the effects of scan protocols on CT-based material extraction to minimize radiation dose while maintaining sufficient image information in small animal studies. The phantom simulation experiments were performed with the high dose (HD), medium dose (MD) and low dose (LD) protocols at 50, 70 and 80 kVp with varying mA s. The reconstructed CT images were segmented based on Hounsfield unit (HU)-physical density (ρ) calibration curves and the dual-energy CT-based (DECT) method. Compared to the (HU;ρ) method performed on CT images acquired with the 80 kVp HD protocol, a 2-fold improvement in segmentation accuracy and a 7.5-fold reduction in radiation dose were observed when the DECT method was performed on CT images acquired with the 50/80 kVp LD protocol, showing the possibility to reduce radiation dose while achieving high segmentation accuracy.
Measurement profiles of nano-scale ion beam for optimized radiation energy losses
NASA Astrophysics Data System (ADS)
Woo, T. H.; Cho, H. S.
2011-10-01
The behavior of charged particles is investigated for nano-scale ion beam therapy using a medical accelerator. Computational work is performed for the Bragg-peak simulation, which is focused on human organ material of pancreas and thyroid. The Results show that the trends of the dose have several different kinds of distributions. Before constructing a heavy ion collider, this study can give us the reliability of the therapeutic effect. Realistic treatment using human organs is calculated in a simple and cost effective manner using the computational code, the Stopping and Range of Ions in Matter 2008 (SRIM 2008). Considering the safety of the therapy, it is suggested to give a patient orient planning of the cancer therapy. The energy losses in ionization and phonon are analyzed, which are the behaviors in the molecular level nano-scopic investigation. The different fluctuations are shown at 150 MeV, where the lowest temperature is found in proton and pancreas case. Finally, the protocol for the radiation therapy is constructed by the simulation in which the procedure for a better therapy is selected. An experimental measurement incorporated with the simulations could be programmed by this protocol.
Anderson, Gillian H; Jenkins, Paul J; McDonald, David A; Van Der Meer, Robert; Morton, Alec; Nugent, Margaret; Rymaszewski, Lech A
2017-09-07
Healthcare faces the continual challenge of improving outcome while aiming to reduce cost. The aim of this study was to determine the micro cost differences of the Glasgow non-operative trauma virtual pathway in comparison to a traditional pathway. Discrete event simulation was used to model and analyse cost and resource utilisation with an activity-based costing approach. Data for a full comparison before the process change was unavailable so we used a modelling approach, comparing a virtual fracture clinic (VFC) with a simulated traditional fracture clinic (TFC). The orthopaedic unit VFC pathway pioneered at Glasgow Royal Infirmary has attracted significant attention and interest and is the focus of this cost study. Our study focused exclusively on patients with non-operative trauma attending emergency department or the minor injuries unit and the subsequent step in the patient pathway. Retrospective studies of patient outcomes as a result of the protocol introductions for specific injuries are presented in association with activity costs from the models. Patients are satisfied with the new pathway, the information provided and the outcome of their injuries (Evidence Level IV). There was a 65% reduction in the number of first outpatient face-to-face (f2f) attendances in orthopaedics. In the VFC pathway, the resources required per day were significantly lower for all staff groups (p≤0.001). The overall cost per patient of the VFC pathway was £22.84 (95% CI 21.74 to 23.92) per patient compared with £36.81 (95% CI 35.65 to 37.97) for the TFC pathway. Our results give a clearer picture of the cost comparison of the virtual pathway over a wholly traditional f2f clinic system. The use of simulation-based stochastic costings in healthcare economic analysis has been limited to date, but this study provides evidence for adoption of this method as a basis for its application in other healthcare settings. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
A Low Cost Microcomputer System for Process Dynamics and Control Simulations.
ERIC Educational Resources Information Center
Crowl, D. A.; Durisin, M. J.
1983-01-01
Discusses a video simulator microcomputer system used to provide real-time demonstrations to strengthen students' understanding of process dynamics and control. Also discusses hardware/software and simulations developed using the system. The four simulations model various configurations of a process liquid level tank system. (JN)
Schoeny, Michael; Risser, Heather; Johnson, Tricia
2016-01-01
Introduction Up to 20% of children demonstrate behavior problems that interfere with relationship development and academic achievement. Parent participation in behavioral parent training programs has been shown to decrease child problem behaviors and promote positive parent-child relationships. However, attendance and parent involvement in face-to-face parent training remain low. Testing the implementation, efficacy, and cost of alternative delivery models is needed to (a) increase the reach and sustainability of parent training interventions and (b) address the barriers to parent participation and implementation of such programs, specifically in primary health care settings. The purpose of this paper is to describe the study protocol evaluating the implementation, efficacy, and cost-effectiveness of delivering the tablet-based ezParent program in pediatric primary care sites. Methods The implementation of the ezParent in four pediatric primary care sites will be evaluated using a descriptive design and cost-effectiveness analysis. The efficacy of the ezParent will be tested using a randomized controlled trial design with 312 parents of 2 to 5 year old children from pediatric primary care settings. Data on parenting and child behavior outcomes will be obtained from all participants at baseline, and 3, 6, and 12 months post baseline. Discussion Integrating and evaluating the implementation of the ezParent in pediatric primary care is an innovative opportunity to promote positive parenting with potential for universal access to the preschool population and for low cost by building on existing infrastructure in pediatric primary care. PMID:27592122
Predictive protocol of flocks with small-world connection pattern.
Zhang, Hai-Tao; Chen, Michael Z Q; Zhou, Tao
2009-01-01
By introducing a predictive mechanism with small-world connections, we propose a new motion protocol for self-driven flocks. The small-world connections are implemented by randomly adding long-range interactions from the leader to a few distant agents, namely, pseudoleaders. The leader can directly affect the pseudoleaders, thereby influencing all the other agents through them efficiently. Moreover, these pseudoleaders are able to predict the leader's motion several steps ahead and use this information in decision making towards coherent flocking with more stable formation. It is shown that drastic improvement can be achieved in terms of both the consensus performance and the communication cost. From the engineering point of view, the current protocol allows for a significant improvement in the cohesion and rigidity of the formation at a fairly low cost of adding a few long-range links embedded with predictive capabilities. Significantly, this work uncovers an important feature of flocks that predictive capability and long-range links can compensate for the insufficiency of each other. These conclusions are valid for both the attractive and repulsive swarm model and the Vicsek model.
Processing experiments on non-Czochralski silicon sheet
NASA Technical Reports Server (NTRS)
Pryor, R. A.; Grenon, L. A.; Sakiotis, N. G.; Pastirik, E. M.; Sparks, T. O.; Legge, R. N.
1981-01-01
A program is described which supports and promotes the development of processing techniques which may be successfully and cost-effectively applied to low-cost sheets for solar cell fabrication. Results are reported in the areas of process technology, cell design, cell metallization, and production cost simulation.
Lichtenberger, John P; Tatum, Peter S; Gada, Satyen; Wyn, Mark; Ho, Vincent B; Liacouras, Peter
2018-03-01
This work describes customized, task-specific simulation models derived from 3D printing in clinical settings and medical professional training programs. Simulation models/task trainers have an array of purposes and desired achievements for the trainee, defining that these are the first step in the production process. After this purpose is defined, computer-aided design and 3D printing (additive manufacturing) are used to create a customized anatomical model. Simulation models then undergo initial in-house testing by medical specialists followed by a larger scale beta testing. Feedback is acquired, via surveys, to validate effectiveness and to guide or determine if any future modifications and/or improvements are necessary. Numerous custom simulation models have been successfully completed with resulting task trainers designed for procedures, including removal of ocular foreign bodies, ultrasound-guided joint injections, nerve block injections, and various suturing and reconstruction procedures. These task trainers have been frequently utilized in the delivery of simulation-based training with increasing demand. 3D printing has been integral to the production of limited-quantity, low-cost simulation models across a variety of medical specialties. In general, production cost is a small fraction of a commercial, generic simulation model, if available. These simulation and training models are customized to the educational need and serve an integral role in the education of our military health professionals.
Steering Control in a Low-Cost Driving Simulator: A Case for the Role of Virtual Vehicle Cab.
Mecheri, Sami; Lobjois, Régis
2018-04-01
The aim of this study was to investigate steering control in a low-cost driving simulator with and without a virtual vehicle cab. In low-cost simulators, the lack of a vehicle cab denies driver access to vehicle width, which could affect steering control, insofar as locomotor adjustments are known to be based on action-scaled visual judgments of the environment. Two experiments were conducted in which steering control with and without a virtual vehicle cab was investigated in a within-subject design, using cornering and straight-lane-keeping tasks. Driving around curves without vehicle cab information made drivers deviate more from the lane center toward the inner edge in right (virtual cab = 4 ± 19 cm; no cab = 42 ± 28 cm; at the apex of the curve, p < .001) but not in left curves. More lateral deviation from the lane center toward the edge line was also found in driving without the virtual cab on straight roads (virtual cab = 21 ± 28 cm; no cab = 36 ± 27 cm; p < .001), whereas driving stability and presence ratings were not affected. In both experiments, the greater lateral deviation in the no-cab condition led to significantly more time driving off the lane. The findings strongly suggest that without cab information, participants underestimate the distance to the right edge of the car (in contrast to the left edge) and thus vehicle width. This produces considerable differences in the steering trajectory. Providing a virtual vehicle cab must be encouraged for more effectively capturing drivers' steering control in low-cost simulators.
NASA Astrophysics Data System (ADS)
Shuaib, Ali; Bourisly, Ali
2018-02-01
Spinal cord injury (SCI) can result in complete or partial loss of sensation and motor function due to interruption along the severed axonal tract(s). SCI can result in tetraplegia or paraplegia, which can have prohibitive lifetime medical costs and result in shorter life expectancy. A promising therapeutic technique that is currently in experimental phase and that has the potential to be used to treat SCI is Low-level light therapy (LLLT). Preclinical studies have shown that LLLT has reparative and regenerative capabilities on transected spinal cords, and that LLLT can enhance axonal sprouting in animal models. However, despite the promising effects of LLLT as a therapy for SCI, it remains difficult to compare published results due to the use of a wide range of illumination parameters (i.e. different wavelengths, fluences, beam types, and beam diameter), and due to the lack of a standardized experimental protocol(s). Before any clinical applications of LLLT for SCI treatment, it is crucial to standardize illumination parameters and efficacy of light delivery. Therefore, in this study we aim to evaluate the light fluence distribution on a 3D voxelated SCI rat model with different illumination parameters (wavelengths: 660, 810, and 980 nm; beam types: Gaussian and Flat; and beam diameters: 0.1, 0.2, and 0.3 cm) for LLLT using Monte Carlo simulation. This study provides an efficient approach to guide researchers in optimizing the illumination parameters for LLLT spinal cord injury in an experimental model and will aid in quantitative and qualitative standardization of LLLT-SCI treatment.
Advertisement-Based Energy Efficient Medium Access Protocols for Wireless Sensor Networks
NASA Astrophysics Data System (ADS)
Ray, Surjya Sarathi
One of the main challenges that prevents the large-scale deployment of Wireless Sensor Networks (WSNs) is providing the applications with the required quality of service (QoS) given the sensor nodes' limited energy supplies. WSNs are an important tool in supporting applications ranging from environmental and industrial monitoring, to battlefield surveillance and traffic control, among others. Most of these applications require sensors to function for long periods of time without human intervention and without battery replacement. Therefore, energy conservation is one of the main goals for protocols for WSNs. Energy conservation can be performed in different layers of the protocol stack. In particular, as the medium access control (MAC) layer can access and control the radio directly, large energy savings is possible through intelligent MAC protocol design. To maximize the network lifetime, MAC protocols for WSNs aim to minimize idle listening of the sensor nodes, packet collisions, and overhearing. Several approaches such as duty cycling and low power listening have been proposed at the MAC layer to achieve energy efficiency. In this thesis, I explore the possibility of further energy savings through the advertisement of data packets in the MAC layer. In the first part of my research, I propose Advertisement-MAC or ADV-MAC, a new MAC protocol for WSNs that utilizes the concept of advertising for data contention. This technique lets nodes listen dynamically to any desired transmission and sleep during transmissions not of interest. This minimizes the energy lost in idle listening and overhearing while maintaining an adaptive duty cycle to handle variable loads. Additionally, ADV-MAC enables energy efficient MAC-level multicasting. An analytical model for the packet delivery ratio and the energy consumption of the protocol is also proposed. The analytical model is verified with simulations and is used to choose an optimal value of the advertisement period. Simulations show that the optimized ADV-MAC provides substantial energy gains (50% to 70% less than other MAC protocols for WSNs such as T-MAC and S-MAC for the scenarios investigated) while faring as well as T-MAC in terms of packet delivery ratio and latency. Although ADV-MAC provides substantial energy gains over S-MAC and T-MAC, it is not optimal in terms of energy savings because contention is done twice -- once in the Advertisement Period and once in the Data Period. In the next part of my research, the second contention in the Data Period is eliminated and the advantages of contention-based and TDMA-based protocols are combined to form Advertisement based Time-division Multiple Access (ATMA), a distributed TDMA-based MAC protocol for WSNs. ATMA utilizes the bursty nature of the traffic to prevent energy waste through advertisements and reservations for data slots. Extensive simulations and qualitative analysis show that with bursty traffic, ATMA outperforms contention-based protocols (S-MAC, T-MAC and ADV-MAC), a TDMA based protocol (TRAMA) and hybrid protocols (Z-MAC and IEEE 802.15.4). ATMA provides energy reductions of up to 80%, while providing the best packet delivery ratio (close to 100%) and latency among all the investigated protocols. Simulations alone cannot reflect many of the challenges faced by real implementations of MAC protocols, such as clock-drift, synchronization, imperfect physical layers, and irregular interference from other transmissions. Such issues may cripple a protocol that otherwise performs very well in software simulations. Hence, to validate my research, I conclude with a hardware implementation of the ATMA protocol on SORA (Software Radio), developed by Microsoft Research Asia. SORA is a reprogrammable Software Defined Radio (SDR) platform that satisfies the throughput and timing requirements of modern wireless protocols while utilizing the rich general purpose PC development environment. Experimental results obtained from the hardware implementation of ATMA closely mirror the simulation results obtained for a single hop network with 4 nodes.
Validation of a Low Dose Simulation Technique for Computed Tomography Images
Muenzel, Daniela; Koehler, Thomas; Brown, Kevin; Žabić, Stanislav; Fingerle, Alexander A.; Waldt, Simone; Bendik, Edgar; Zahel, Tina; Schneider, Armin; Dobritz, Martin; Rummeny, Ernst J.; Noël, Peter B.
2014-01-01
Purpose Evaluation of a new software tool for generation of simulated low-dose computed tomography (CT) images from an original higher dose scan. Materials and Methods Original CT scan data (100 mAs, 80 mAs, 60 mAs, 40 mAs, 20 mAs, 10 mAs; 100 kV) of a swine were acquired (approved by the regional governmental commission for animal protection). Simulations of CT acquisition with a lower dose (simulated 10–80 mAs) were calculated using a low-dose simulation algorithm. The simulations were compared to the originals of the same dose level with regard to density values and image noise. Four radiologists assessed the realistic visual appearance of the simulated images. Results Image characteristics of simulated low dose scans were similar to the originals. Mean overall discrepancy of image noise and CT values was −1.2% (range −9% to 3.2%) and −0.2% (range −8.2% to 3.2%), respectively, p>0.05. Confidence intervals of discrepancies ranged between 0.9–10.2 HU (noise) and 1.9–13.4 HU (CT values), without significant differences (p>0.05). Subjective observer evaluation of image appearance showed no visually detectable difference. Conclusion Simulated low dose images showed excellent agreement with the originals concerning image noise, CT density values, and subjective assessment of the visual appearance of the simulated images. An authentic low-dose simulation opens up opportunity with regard to staff education, protocol optimization and introduction of new techniques. PMID:25247422
Low-Cost 3D Printers Enable High-Quality and Automated Sample Preparation and Molecular Detection
Chan, Kamfai; Coen, Mauricio; Hardick, Justin; Gaydos, Charlotte A.; Wong, Kah-Yat; Smith, Clayton; Wilson, Scott A.; Vayugundla, Siva Praneeth; Wong, Season
2016-01-01
Most molecular diagnostic assays require upfront sample preparation steps to isolate the target’s nucleic acids, followed by its amplification and detection using various nucleic acid amplification techniques. Because molecular diagnostic methods are generally rather difficult to perform manually without highly trained users, automated and integrated systems are highly desirable but too costly for use at point-of-care or low-resource settings. Here, we showcase the development of a low-cost and rapid nucleic acid isolation and amplification platform by modifying entry-level 3D printers that cost between $400 and $750. Our modifications consisted of replacing the extruder with a tip-comb attachment that houses magnets to conduct magnetic particle-based nucleic acid extraction. We then programmed the 3D printer to conduct motions that can perform high-quality extraction protocols. Up to 12 samples can be processed simultaneously in under 13 minutes and the efficiency of nucleic acid isolation matches well against gold-standard spin-column-based extraction technology. Additionally, we used the 3D printer’s heated bed to supply heat to perform water bath-based polymerase chain reactions (PCRs). Using another attachment to hold PCR tubes, the 3D printer was programmed to automate the process of shuttling PCR tubes between water baths. By eliminating the temperature ramping needed in most commercial thermal cyclers, the run time of a 35-cycle PCR protocol was shortened by 33%. This article demonstrates that for applications in resource-limited settings, expensive nucleic acid extraction devices and thermal cyclers that are used in many central laboratories can be potentially replaced by a device modified from inexpensive entry-level 3D printers. PMID:27362424
An Efficient Next Hop Selection Algorithm for Multi-Hop Body Area Networks
Ayatollahitafti, Vahid; Ngadi, Md Asri; Mohamad Sharif, Johan bin; Abdullahi, Mohammed
2016-01-01
Body Area Networks (BANs) consist of various sensors which gather patient’s vital signs and deliver them to doctors. One of the most significant challenges faced, is the design of an energy-efficient next hop selection algorithm to satisfy Quality of Service (QoS) requirements for different healthcare applications. In this paper, a novel efficient next hop selection algorithm is proposed in multi-hop BANs. This algorithm uses the minimum hop count and a link cost function jointly in each node to choose the best next hop node. The link cost function includes the residual energy, free buffer size, and the link reliability of the neighboring nodes, which is used to balance the energy consumption and to satisfy QoS requirements in terms of end to end delay and reliability. Extensive simulation experiments were performed to evaluate the efficiency of the proposed algorithm using the NS-2 simulator. Simulation results show that our proposed algorithm provides significant improvement in terms of energy consumption, number of packets forwarded, end to end delay and packet delivery ratio compared to the existing routing protocol. PMID:26771586
Nenov, Artur; Mukamel, Shaul; Garavelli, Marco; Rivalta, Ivan
2015-08-11
First-principles simulations of two-dimensional electronic spectroscopy in the ultraviolet region (2DUV) require computationally demanding multiconfigurational approaches that can resolve doubly excited and charge transfer states, the spectroscopic fingerprints of coupled UV-active chromophores. Here, we propose an efficient approach to reduce the computational cost of accurate simulations of 2DUV spectra of benzene, phenol, and their dimer (i.e., the minimal models for studying electronic coupling of UV-chromophores in proteins). We first establish the multiconfigurational recipe with the highest accuracy by comparison with experimental data, providing reference gas-phase transition energies and dipole moments that can be used to construct exciton Hamiltonians involving high-lying excited states. We show that by reducing the active spaces and the number of configuration state functions within restricted active space schemes, the computational cost can be significantly decreased without loss of accuracy in predicting 2DUV spectra. The proposed recipe has been successfully tested on a realistic model proteic system in water. Accounting for line broadening due to thermal and solvent-induced fluctuations allows for direct comparison with experiments.
Rogawski, Elizabeth T; Platts-Mills, James A; Colgate, E Ross; Haque, Rashidul; Zaman, K; Petri, William A; Kirkpatrick, Beth D
2018-03-05
The low efficacy of rotavirus vaccines in clinical trials performed in low-resource settings may be partially explained by acquired immunity from natural exposure, especially in settings with high disease incidence. In a clinical trial of monovalent rotavirus vaccine in Bangladesh, we compared the original per-protocol efficacy estimate to efficacy derived from a recurrent events survival model in which children were considered naturally exposed and potentially immune after their first rotavirus diarrhea (RVD) episode. We then simulated trial cohorts to estimate the expected impact of prior exposure on efficacy estimates for varying rotavirus incidence rates and vaccine efficacies. Accounting for natural immunity increased the per-protocol vaccine efficacy estimate against severe RVD from 63.1% (95% confidence interval [CI], 33.0%-79.7%) to 70.2% (95% CI, 44.5%-84.0%) in the postvaccination period, and original year 2 efficacy was underestimated by 14%. The simulations demonstrated that this expected impact increases linearly with RVD incidence, will be greatest for vaccine efficacies near 50%, and can reach 20% in settings with high incidence and low efficacy. High rotavirus incidence leads to predictably lower vaccine efficacy estimates due to the acquisition of natural immunity in unvaccinated children, and this phenomenon should be considered when comparing efficacy estimates across settings. NCT01375647.
A land-surface Testbed for EOSDIS
NASA Technical Reports Server (NTRS)
Emery, William; Kelley, Tim
1994-01-01
The main objective of the Testbed project was to deliver satellite images via the Internet to scientific and educational users free of charge. The main method of operations was to store satellite images on a low cost tape library system, visually browse the raw satellite data, access the raw data filed, navigate the imagery through 'C' programming and X-Windows interface software, and deliver the finished image to the end user over the Internet by means of file transfer protocol methods. The conclusion is that the distribution of satellite imagery by means of the Internet is feasible, and the archiving of large data sets can be accomplished with low cost storage systems allowing multiple users.
Gaudin, V; Hedou, C; Rault, A; Verdon, E
2010-07-01
The STAR protocol is a Five Plate Test (FPT) developed several years ago at the Community Reference Laboratory (CRL) for the screening of antimicrobial residues in milk and muscle. This paper presents the validation of this method according to European Decision 2002/657/EC and to an internal guideline for validation. A validation protocol based on 'simulated tissues' and on a list of 16 representative antimicrobials to be validated was implemented in our laboratory during several months for the STAR protocol. The performance characteristics of the method were determined (specificity, detection capabilities CCbeta, applicability, ruggedness). In conclusion, the STAR protocol is applicable to the broad-spectrum detection of antibiotic residues in muscles of different animal species (pig, cattle, sheep, poultry). The method has good specificity (false-positive rate = 4%). The detection capabilities were determined for 16 antibiotics from different families in relation to their respective maximum residue limit (MRL): beta-lactams (penicillins and cephalosporins < or = MRL), tetracyclines (< or = MRL and < or = 2.5 MRL), macrolides (2 MRL), quinolones (< or = 2 MRL), some sulphonamides (< or = 3 MRL), and trimethoprim (2 MRL). However, the sensitivity of the STAR protocol towards aminoglycosides (> 8 MRL) and florfenicol (< or = 10 MRL) was unsatisfactory (>MRL). The two objectives of this study were met: firstly, to validate the STAR protocol according to European Decision 2002/657/EC, then to demonstrate that the validation guideline developed to implement this decision is applicable to microbiological plate tests even for muscle. The use of simulated tissue appeared a good compromise between spiked discs with antibiotic solutions and incurred tissues. In addition, the choice of a list of representative antibiotics allowed the reduction of the scope of the validation, which was already costly in time and effort.
Technology Developments Integrating a Space Network Communications Testbed
NASA Technical Reports Server (NTRS)
Kwong, Winston; Jennings, Esther; Clare, Loren; Leang, Dee
2006-01-01
As future manned and robotic space explorations missions involve more complex systems, it is essential to verify, validate, and optimize such systems through simulation and emulation in a low cost testbed environment. The goal of such a testbed is to perform detailed testing of advanced space and ground communications networks, technologies, and client applications that are essential for future space exploration missions. We describe the development of new technologies enhancing our Multi-mission Advanced Communications Hybrid Environment for Test and Evaluation (MACHETE) that enable its integration in a distributed space communications testbed. MACHETE combines orbital modeling, link analysis, and protocol and service modeling to quantify system performance based on comprehensive considerations of different aspects of space missions. It can simulate entire networks and can interface with external (testbed) systems. The key technology developments enabling the integration of MACHETE into a distributed testbed are the Monitor and Control module and the QualNet IP Network Emulator module. Specifically, the Monitor and Control module establishes a standard interface mechanism to centralize the management of each testbed component. The QualNet IP Network Emulator module allows externally generated network traffic to be passed through MACHETE to experience simulated network behaviors such as propagation delay, data loss, orbital effects and other communications characteristics, including entire network behaviors. We report a successful integration of MACHETE with a space communication testbed modeling a lunar exploration scenario. This document is the viewgraph slides of the presentation.
FLTSATCOM interoperability applications
NASA Astrophysics Data System (ADS)
Woolford, Lynn
A mobile Fleet Satellite Communications (FLTSATCOM) system called the Mobile Operational Control Center (MOCC) was developed which has demonstrated the ability to be interoperable with many of the current FLTSATCOM command and control channels. This low-cost system is secure in all its communications, is lightweight, and provides a gateway for other communications formats. The major elements of this system are made up of a personal computer, a protocol microprocessor, and off-the-shelf mobile communication components. It is concluded that with both FLTSATCOM channel protocol and data format interoperability, the MOCC has the ability provide vital information in or near real time, which significantly improves mission effectiveness.
Low-cost coherent receiver for long-reach optical access network using single-ended detection.
Zhang, Xuebing; Li, Zhaohui; Li, Jianping; Yu, Changyuan; Lau, Alan Pak Tao; Lu, Chao
2014-09-15
A low-cost coherent receiver using two 2×3 optical hybrids and single-ended detection is proposed for long-reach optical access network. This structure can detect the two polarization components of polarization division multiplexing (PDM) signals. Polarization de-multiplexing and signal-to-signal beat interference (SSBI) cancellation are realized by using only three photodiodes. Simulation results for 40 Gb/s PDM-OFDM transmissions indicate that the low-cost coherent receiver has 3.2 dB optical signal-to-noise ratio difference compared with the theoretical value.
Blanchet, Marie-Cécile; Frering, Vincent; Gignoux, Benoît; Matussière, Yann; Oudar, Philippe; Noël, Romain; Mirabaud, Alban
2018-05-12
"Enhanced recovery after surgery" (ERAS) protocols may reduce morbidity, length of hospital stay (LOS), and costs. During the 4-year evolution of a bariatric ERAS protocol, we found that administration of thrombophylaxis selectively to high-risk morbidly obese patients (assessed postoperatively by Caprini score ≥ 3) undergoing omega loop gastric bypass ("mini" gastric bypass) or sleeve gastrectomy resulted in safe outcomes. Both procedures proved equally effective with this protocol. The vast majority of rapidly mobilized, low-risk patients did not appear to require antithrombotic heparin. Similar to other reported ERAS outcomes, our recent year's results in 485 patients included a mean LOS of 1.08 ± 0.64 days (range 1-14), with 460 (95.0%) discharged on day 1 and 99.6% by day 2. There were 13 30-day complications (2.7%), two reinterventions (0.4%), and no hemorrhages.
Epifluorescent direct-write photolithography for microfluidic applications
NASA Astrophysics Data System (ADS)
Higgins, MacCallister; Geiger, Emil J.
2015-01-01
We present a technique for fabricating soft-lithography molds created using an epifluorescent microscope. By focusing the UV light emitted from a Hg arc lamp, we demonstrate the ability to direct-write photoresist features with a minimum resolution of 45 μm. This resolution is satisfactory for many microfluidic applications. A major advantage of this technique is its low cost, both in terms of capital investment and on-going expenditures. Furthermore, by using a motorized stage, we can quickly fabricate a design on demand, eliminating the need, cost, and lead-time required for a photomask. With the addition of an electronic shutter, complicated separate structures can be imaged and utilized to make a wide range of microfluidic devices. We demonstrate this technique using dry-film resist due to its low cost, ease of application, and less stringent safety protocols.
ter Wee, Marieke M; Coupé, Veerle MH; den Uyl, Debby; Blomjous, Birgit S; Kooijmans, Esmee; Kerstens, Pit JSM; Nurmohamed, Mike T; van Schaardenburg, Dirkjan; Voskuyl, Alexandre E; Boers, Maarten; Lems, Willem F
2017-01-01
Objective To evaluate if COmbinatie therapie Bij Reumatoïde Artritis (COBRA)-light therapy is cost-effective in treating patients with early rheumatoid arthritis (RA) compared with COBRA therapy. Methods This economic evaluation was performed next to the open-label, randomised non-inferiority COBRA-light trial in 164 patients with early RA. Non-responders to COBRA or COBRA-light received etanercept (50 mg/week) for 3–6 months. The societal perspective analysis took medical direct, non-medical direct and indirect costs into account. Costs were measured with patient cost diaries for the follow-up period of 52 weeks. Bootstrapping techniques estimated uncertainty around the cost-effectiveness ratios, presented in cost-effectiveness planes. Results 164 patients were randomised to either COBRA or COBRA-light strategy. At week 52, COBRA-light proved to be non-inferior to COBRA therapy on all clinical outcome measures. The results of the base-case cost-utility analysis (intention-to-treat analyses) revealed that COBRA-light strategy is more expensive (k€9.3 (SD 0.9) compared with COBRA (k€7.2 (SD 0.8)), but the difference in costs were not significant (k€2.0; 95% CI –0.3 to 4.4). Also, both strategies produced similar quality-adjusted life-years (QALYs). The sensitivity analyses showed robustness of these results. In a per-protocol sensitivity analysis, in which costs of etanercept were assumed to be provided as prescribed according to protocol, both arms had much higher costs: COBRA-light: k€11.5 (8.3) compared with k€8.5 (6.8) for COBRA, and the difference in costs was significant (k€2.9; 0.6 to 5.3). Conclusions In the base-case cost-utility analysis, the two strategies produced similar QALYs for similar costs. But it is anticipated that if protocol had been followed correctly, the COBRA-light strategy would have been more costly due to additional etanercept costs, for a limited health gain. Given the limited added benefit and high costs of starting etanercept in the presence of low disease activity in our trial, such a strategy needs better justification than is available now. Trial registration number 55552928, Results. PMID:29119006
Cost savings using a protocol approach to manage anemia in a hemodialysis unit.
Charlesworth, Emily C; Richardson, Robert M; Battistella, Marisa
2014-01-01
National guidelines recommend using anemia management protocols to guide treatment. The objective of this study was to determine if an anemia management protocol would improve hemoglobin (Hgb) indices in hemodialysis patients and to measure whether the protocol would reduce the use and cost of darbepoetin alfa (DBO) and intravenous (IV) iron in hemodialysis patients. An anemia management protocol was created and implemented for hemodialysis patients at our institution. A retrospective observational review of the use of DBO and IV iron as well as changes in Hgb, transferrin saturation and ferritin in 174 patients was conducted 6 months before and after implementation of the anemia protocol. The number of Hgb measurements in the target range increased from 44.3 to 46.0% (p = 0.48) after protocol implementation. The mean weekly dose of DBO was reduced from 34.56 ± 31.12 to 31.11 ± 28.64 μg post-protocol implementation (p = 0.011), which translated to a cost savings of USD 41,649 over 6 months. The mean monthly IV iron dose also decreased from 139.56 ± 98.83 to 97.65 ± 79.05 mg (p < 0.005), a cost savings of USD 18,594 over the same time period. The use of an anemia management protocol resulted in the deprescribing of DBO and iron agents while increasing the number of patients in the target Hgb range, which led to significant cost savings in the treatment of anemia.
Low-cost phantom for stereotactic breast biopsy training.
Larrison, Matthew; DiBona, Alex; Hogg, David E
2006-10-01
This article reports on the construction of a low-cost phantom to be used for training technologists, residents, and radiologists to perform stereotactic breast biopsy. The model is adaptable to a variety of biopsy devices and realistically simulates the aspects of stereotactic breast biopsy. We believe our model provides an excellent alternative to more expensive commercial products.
Reduced exercise time in competitive simulations consequent to low level ozone exposure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schelegle, E.S.; Adams, W.C.
Ten highly trained endurance athletes were studied to determine the effects of exposure to low ozone (O/sub 3/) concentrations on simulated competitive endurance performance and associated physiological and subjective symptom responses. Each subject was randomly exposed to filtered air (FA), and to 0.12, 0.18, and 0.24 ppm O/sub 3/ while performing a 1 h competitive simulation protocol on a bicycle ergometer. Endurance performance was evaluated by the number of subjects unable to complete rides (last 30 min at an intense work load of approximately 86% VO/sub 2/max). All subjects completed the FA exposure, whereas one, five, and seven subjects didmore » not complete the 0.12, 0.18, and 0.24 ppm O/sub 3/ exposures, respectively. Statistical analysis indicated a significant (P less than 0.05) increase in the inability of subjects to complete the competitive simulations with increasing O/sub 3/ concentration, including a significant difference between the 0.24 ppm O/sub 3/ and FA exposure. Significant decreases (P less than 0.05) were also observed following the 0.18 and 0.24 ppm O/sub 3/ exposures, respectively, in forced vital capacity (-7.8 and -9.9%), and forced expiratory volume in 1 s (-5.8 and -10.5%). No significant O/sub 3/ effect was observed for exercise respiratory metabolism or ventilatory pattern responses. However, the number of reported subjective symptoms increased significantly following the 0.18 and 0.24 ppm O/sub 3/ protocols. These data demonstrate significant decrements in simulated competitive endurance performance and in pulmonary function, with accompanying enhanced subjective symptoms, following exposure to low O/sub 3/ levels commonly observed in numerous metropolitan environments during the summer months.« less
Simulation and Implementation of Moth-eye Structures as a Broadband Anti-Reflective Layer
NASA Astrophysics Data System (ADS)
Deshpande, Ketan S.
Conventional single layer thin anti-reflective coatings (ARCs) are only suitable for narrowband applications. A multilayer film stack is often employed for broadband applications. A coating of multiple layers with alternating low and high refractive index materials increases the overall cost of the system. This makes multilayer ARCs unsuitable for low-cost broadband applications. Since the discovery of moth-eye corneal nipple patterns and their potential applicability in the field of broadband ARCs, many studies have been carried out to fabricate these bio-inspired nanostructures with available manufacturing processes. Plasma etching processes used in microelectronic manufacturing are applied for creating these nanostructures at the Rochester Institute of Technology's Semiconductor & Microsystems Fabrication Laboratory (SMFL). Atomic Force Microscope (AFM) scanned surfaces of the nanostructure layer are simulated and characterized for their optical properties using a Finite-Difference Time Domain (FDTD) simulator from Lumerical Solutions, Inc. known as FDTD Solutions. Simulation results show that the layer is anti-reflective over 50 to 350 nm broadband of wavelengths at 0° angle of incidence. These simulation results were supported by ellipsometer reflection measurements off the actual samples at multiple angles of light incidence, which show a 10% to 15% decrease in reflection for 240 to 400 nm wavelengths. Further improvements in the optical efficiency of these structures can be achieved through simulation-fabrication-characterization cycles performed for this project. The optimized nanostructures can then serve the purpose of low-cost anti-reflective coatings for solar cells and similar applications.
Lerman, Imanuel R; Souzdalnitski, Dmitri; Narouze, Samer
2012-01-01
This technical report describes a durable, low-cost, anatomically accurate, and easy-to-prepare combined ultrasound (US) and fluoroscopic phantom of the cervical spine. This phantom is meant to augment training in US- and fluoroscopic-guided pain medicine procedures. The combined US and fluoroscopic phantom (CUF-P) is prepared from commercially available liquid plastic that is ordinarily used to prepare synthetic fishing lures. The liquid plastic is heated and then poured into a metal canister that houses an anatomical cervical spine model. Drops of dark purple dye are added to make the phantom opaque. After cooling, tubing is attached to the CUF-P to simulate blood vessels. The CUF-P accurately simulates human tissue by imitating both the tactile texture of skin and the haptic resistance of human tissue as the needle is advanced. This phantom contains simulated fluid-filled vertebral arteries that exhibit pulsed flow under color Doppler US. Under fluoroscopic examination, the CUF-P-simulated vertebral arteries also exhibit uptake of contrast dye if mistakenly injected. The creation of a training phantom allows the pain physician to practice needle positioning technique while simultaneously visualizing both targeted and avoidable vascular structures under US and fluoroscopic guidance. This low-cost CUF-P is easy to prepare and is reusable, making it an attractive alternative to current homemade and commercially available phantom simulators.
Effectiveness of sequential automatic-manual home respiratory polygraphy scoring.
Masa, Juan F; Corral, Jaime; Pereira, Ricardo; Duran-Cantolla, Joaquin; Cabello, Marta; Hernández-Blasco, Luis; Monasterio, Carmen; Alonso-Fernandez, Alberto; Chiner, Eusebi; Vázquez-Polo, Francisco-José; Montserrat, Jose M
2013-04-01
Automatic home respiratory polygraphy (HRP) scoring functions can potentially confirm the diagnosis of sleep apnoea-hypopnoea syndrome (SAHS) (obviating technician scoring) in a substantial number of patients. The result would have important management and cost implications. The aim of this study was to determine the diagnostic cost-effectiveness of a sequential HRP scoring protocol (automatic and then manual for residual cases) compared with manual HRP scoring, and with in-hospital polysomnography. We included suspected SAHS patients in a multicentre study and assigned them to home and hospital protocols at random. We constructed receiver operating characteristic (ROC) curves for manual and automatic scoring. Diagnostic agreement for several cut-off points was explored and costs for two equally effective alternatives were calculated. Of 366 randomised patients, 348 completed the protocol. Manual scoring produced better ROC curves than automatic scoring. There was no sensitive automatic or subsequent manual HRP apnoea-hypopnoea index (AHI) cut-off point. The specific cut-off points for automatic and subsequent manual HRP scorings (AHI >25 and >20, respectively) had a specificity of 93% for automatic and 94% for manual scorings. The costs of manual protocol were 9% higher than sequential HRP protocol; these were 69% and 64%, respectively, of the cost of the polysomnography. A sequential HRP scoring protocol is a cost-effective alternative to polysomnography, although with limited cost savings compared to HRP manual scoring.
Strategies that reduce 90-day readmissions and inpatient costs after liver transplantation.
Zeidan, Joseph H; Levi, David M; Pierce, Ruth; Russo, Mark W
2018-04-25
Liver transplantation is hospital-resource intensive and associated with high rates of readmission. We have previously shown a reduction in 30-day readmission rates by implementing a specifically designed protocol to increase access to outpatient care. To determine if strategies that reduce 30-day readmission after liver transplant were effective in also reducing 90-day readmission rates and costs. A protocol was developed to reduce inpatient readmissions after liver transplant that expanded outpatient services and provided alternatives to readmission. The 90-day readmission rates and costs were compared before and implementing strategies outlined in the protocol. Multivariable analysis was used to control for potential confounding factors. Over the study period 304 adult primary liver transplants were performed on patients with a median biologic MELD of 22. 112 (37%) patients were readmitted within 90 days of transplant. The readmission rates before and after implementation of the protocol were 53% and 26% respectively, p<0.001. The most common reason for readmission was elevated liver tests/rejection (24%). In multivariable analysis, the protocol remained associated with avoiding readmission, OR=0.33, [95% CI 0.20,0.55], p<0.001. The median length of stay after transplant preprotocol and postprotocol was 8 and 7 days, respectively. A greater proportion of patients were discharged to hospital lodging post protocol, 10% versus 19%, p=0.03. 90-day readmissions costs were reduced by 55% but total 90 day costs by only 2.7% due to higher outpatient costs and index admission costs. 90-day readmission rates and readmission costs can be reduced by improving access to outpatient services and hospital local lodging. Total 90-day costs were similar between the two groups because of higher outpatient costs after the protocol was introduced. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.
Progress through precedent: Going where no helicopter simulator has gone before
NASA Technical Reports Server (NTRS)
Adams, Richard J.
1992-01-01
Helicopter simulators have been approved by means of special exemption; there are no FAA standards for simulators used in training or airmen Certification checking. The fixed-wing industry provides a precedent which can be used for expediting implementation of helicopter simulators. The analysis in this paper is founded on the experience with that precedent and is driven by a clear definition of helicopter user needs for (1) improved training at lower cost, (2) more comprehensive emergency training at lower risk, (3) increased fidelity of transition and instrument training compared with low-cost aircraft alternatives, and (4) certification credit for improved simulator training.
2007-03-01
provides a means for anyone who has access to an Internet connection to collect or disseminate information on a global scale at a very low cost. The......AIR UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base, Ohio APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED
Deterministic generation of remote entanglement with active quantum feedback
Martin, Leigh; Motzoi, Felix; Li, Hanhan; ...
2015-12-10
We develop and study protocols for deterministic remote entanglement generation using quantum feedback, without relying on an entangling Hamiltonian. In order to formulate the most effective experimentally feasible protocol, we introduce the notion of average-sense locally optimal feedback protocols, which do not require real-time quantum state estimation, a difficult component of real-time quantum feedback control. We use this notion of optimality to construct two protocols that can deterministically create maximal entanglement: a semiclassical feedback protocol for low-efficiency measurements and a quantum feedback protocol for high-efficiency measurements. The latter reduces to direct feedback in the continuous-time limit, whose dynamics can bemore » modeled by a Wiseman-Milburn feedback master equation, which yields an analytic solution in the limit of unit measurement efficiency. Our formalism can smoothly interpolate between continuous-time and discrete-time descriptions of feedback dynamics and we exploit this feature to derive a superior hybrid protocol for arbitrary nonunit measurement efficiency that switches between quantum and semiclassical protocols. Lastly, we show using simulations incorporating experimental imperfections that deterministic entanglement of remote superconducting qubits may be achieved with current technology using the continuous-time feedback protocol alone.« less
Performance Improvement in Geographic Routing for Vehicular Ad Hoc Networks
Kaiwartya, Omprakash; Kumar, Sushil; Lobiyal, D. K.; Abdullah, Abdul Hanan; Hassan, Ahmed Nazar
2014-01-01
Geographic routing is one of the most investigated themes by researchers for reliable and efficient dissemination of information in Vehicular Ad Hoc Networks (VANETs). Recently, different Geographic Distance Routing (GEDIR) protocols have been suggested in the literature. These protocols focus on reducing the forwarding region towards destination to select the Next Hop Vehicles (NHV). Most of these protocols suffer from the problem of elevated one-hop link disconnection, high end-to-end delay and low throughput even at normal vehicle speed in high vehicle density environment. This paper proposes a Geographic Distance Routing protocol based on Segment vehicle, Link quality and Degree of connectivity (SLD-GEDIR). The protocol selects a reliable NHV using the criteria segment vehicles, one-hop link quality and degree of connectivity. The proposed protocol has been simulated in NS-2 and its performance has been compared with the state-of-the-art protocols: P-GEDIR, J-GEDIR and V-GEDIR. The empirical results clearly reveal that SLD-GEDIR has lower link disconnection and end-to-end delay, and higher throughput as compared to the state-of-the-art protocols. It should be noted that the performance of the proposed protocol is preserved irrespective of vehicle density and speed. PMID:25429415
Performance improvement in geographic routing for Vehicular Ad Hoc Networks.
Kaiwartya, Omprakash; Kumar, Sushil; Lobiyal, D K; Abdullah, Abdul Hanan; Hassan, Ahmed Nazar
2014-11-25
Geographic routing is one of the most investigated themes by researchers for reliable and efficient dissemination of information in Vehicular Ad Hoc Networks (VANETs). Recently, different Geographic Distance Routing (GEDIR) protocols have been suggested in the literature. These protocols focus on reducing the forwarding region towards destination to select the Next Hop Vehicles (NHV). Most of these protocols suffer from the problem of elevated one-hop link disconnection, high end-to-end delay and low throughput even at normal vehicle speed in high vehicle density environment. This paper proposes a Geographic Distance Routing protocol based on Segment vehicle, Link quality and Degree of connectivity (SLD-GEDIR). The protocol selects a reliable NHV using the criteria segment vehicles, one-hop link quality and degree of connectivity. The proposed protocol has been simulated in NS-2 and its performance has been compared with the state-of-the-art protocols: P-GEDIR, J-GEDIR and V-GEDIR. The empirical results clearly reveal that SLD-GEDIR has lower link disconnection and end-to-end delay, and higher throughput as compared to the state-of-the-art protocols. It should be noted that the performance of the proposed protocol is preserved irrespective of vehicle density and speed.
Wu, Jing; Liu, Xianhu; Wang, Lili; Dong, Lijun; Pu, Qiaosheng
2012-01-21
An economical fluorescence detector was developed with an LED as the exciting source and a low-cost avalanche photodiode (APD) module as a photon sensor. The detector was arranged in an epifluorescence configuration using a microscope objective (20× or 40×) and a dichroic mirror. The low-cost APD was biased by a direct current (DC) high voltage power supply at 121 V, which is much lower than that normally used for a PMT. Both DC and square wave (SW) supplies were used to power the LED and different data treatment protocols, such as simple average for DC mode, software based lock-in amplification and time specific average for SW mode, were tested to maximize the signal-to-noise ratio. Using an LED at a DC mode with simple data averaging, a limit of detection of 0.2 nmol L(-1) for sodium fluorescein was attained, which is among the lowest ever achieved with an LED as an excitation source. The detector was successfully used in both capillary and chip electrophoresis. The most significant advantages of the detector are the compact size and low cost of its parts. The aim of the work is to prove that widely available, low-cost components for civilian use can be successfully used for miniaturized analytical devices.
Distributed Dynamic Host Configuration Protocol (D2HCP)
Villalba, Luis Javier García; Matesanz, Julián García; Orozco, Ana Lucila Sandoval; Díaz, José Duván Márquez
2011-01-01
Mobile Ad Hoc Networks (MANETs) are multihop wireless networks of mobile nodes without any fixed or preexisting infrastructure. The topology of these networks can change randomly due to the unpredictable mobility of nodes and their propagation characteristics. In most networks, including MANETs, each node needs a unique identifier to communicate. This work presents a distributed protocol for dynamic node IP address assignment in MANETs. Nodes of a MANET synchronize from time to time to maintain a record of IP address assignments in the entire network and detect any IP address leaks. The proposed stateful autoconfiguration scheme uses the OLSR proactive routing protocol for synchronization and guarantees unique IP addresses under a variety of network conditions, including message losses and network partitioning. Simulation results show that the protocol incurs low latency and communication overhead for IP address assignment. PMID:22163856
Distributed Dynamic Host Configuration Protocol (D2HCP).
Villalba, Luis Javier García; Matesanz, Julián García; Orozco, Ana Lucila Sandoval; Díaz, José Duván Márquez
2011-01-01
Mobile Ad Hoc Networks (MANETs) are multihop wireless networks of mobile nodes without any fixed or preexisting infrastructure. The topology of these networks can change randomly due to the unpredictable mobility of nodes and their propagation characteristics. In most networks, including MANETs, each node needs a unique identifier to communicate. This work presents a distributed protocol for dynamic node IP address assignment in MANETs. Nodes of a MANET synchronize from time to time to maintain a record of IP address assignments in the entire network and detect any IP address leaks. The proposed stateful autoconfiguration scheme uses the OLSR proactive routing protocol for synchronization and guarantees unique IP addresses under a variety of network conditions, including message losses and network partitioning. Simulation results show that the protocol incurs low latency and communication overhead for IP address assignment.
W-MAC: A Workload-Aware MAC Protocol for Heterogeneous Convergecast in Wireless Sensor Networks
Xia, Ming; Dong, Yabo; Lu, Dongming
2011-01-01
The power consumption and latency of existing MAC protocols for wireless sensor networks (WSNs) are high in heterogeneous convergecast, where each sensor node generates different amounts of data in one convergecast operation. To solve this problem, we present W-MAC, a workload-aware MAC protocol for heterogeneous convergecast in WSNs. A subtree-based iterative cascading scheduling mechanism and a workload-aware time slice allocation mechanism are proposed to minimize the power consumption of nodes, while offering a low data latency. In addition, an efficient schedule adjustment mechanism is provided for adapting to data traffic variation and network topology change. Analytical and simulation results show that the proposed protocol provides a significant energy saving and latency reduction in heterogeneous convergecast, and can effectively support data aggregation to further improve the performance. PMID:22163753
Emerging Role of Three-Dimensional Printing in Simulation in Otolaryngology.
VanKoevering, Kyle K; Malloy, Kelly Michele
2017-10-01
Simulation is rapidly expanding across medicine as a valuable component of trainee education. For procedural simulation, development of low-cost simulators that allow a realistic, haptic experience for learners to practice maneuvers while appreciating anatomy has become highly valuable. Otolaryngology has seen significant advancements in development of improved, specialty-specific simulators with the expansion of three-dimensional (3D) printing. This article highlights the fundamental components of 3D printing and the multitude of subspecialty simulators that have been developed with the assistance of 3D printing. It briefly discusses important considerations such as cost, fidelity, and validation where available in the literature. Copyright © 2017 Elsevier Inc. All rights reserved.
Semi-physical Simulation Platform of a Parafoil Nonlinear Dynamic System
NASA Astrophysics Data System (ADS)
Gao, Hai-Tao; Yang, Sheng-Bo; Zhu, Er-Lin; Sun, Qing-Lin; Chen, Zeng-Qiang; Kang, Xiao-Feng
2013-11-01
Focusing on the problems in the process of simulation and experiment on a parafoil nonlinear dynamic system, such as limited methods, high cost and low efficiency we present a semi-physical simulation platform. It is designed by connecting parts of physical objects to a computer, and remedies the defect that a computer simulation is divorced from a real environment absolutely. The main components of the platform and its functions, as well as simulation flows, are introduced. The feasibility and validity are verified through a simulation experiment. The experimental results show that the platform has significance for improving the quality of the parafoil fixed-point airdrop system, shortening the development cycle and saving cost.
Anaemia management protocols in the care of haemodialysis patients: examining patient outcomes.
Saunders, Sushila; MacLeod, Martha L P; Salyers, Vince; MacMillan, Peter D; Ogborn, Malcolm R
2013-08-01
To determine whether the use of a nurse-driven protocol in the haemodialysis setting is as safe and effective as traditional physician-driven approaches to anaemia management. The role of haemodialysis nurses in renal anaemia management has evolved through the implementation of nurse-driven protocols, addressing the trend of exceeding haemoglobin targets and rising costs of erythropoietin-stimulating agents. Retrospective, non-equivalent case control group design. The sample was from three haemodialysis units in a control group (n = 64) and three haemodialysis units in a protocol group (n = 43). The protocol group used a nurse-driven renal anaemia management protocol, while the control group used a traditional physician-driven approach to renal anaemia management. All retrospective data were obtained from a provincial renal database. Data were analysed using chi-square tests and t-tests. Patient outcomes examined were haemoglobin levels, transferrin saturation levels, erythropoietin-stimulating agents use and intravenous iron use. Cost comparisons were determined using average use of erythropoietin-stimulating agents and intravenous iron. Control and protocol groups reached haemoglobin target levels. In the protocol group, 75% reached transferrin saturation target levels in comparison with 25% of the control group. Use and costs for iron was higher in the control group, while use and costs for erythropoietin was higher in the protocol group. The higher usage of erythropoietin-stimulating agents was potentially related to comorbid conditions amongst the protocol group. A nurse-driven protocol approach to renal anaemia management was as effective as the physician-driven approach in reaching haemoglobin and transferrin saturation levels. Further examination of the use and dosing of erythropoietin-stimulating agents and intravenous iron, their impact on haemoglobin levels related to patient comorbidities and subsequent cost effectiveness of protocols is required. Using a nurse-driven protocol in practice supports the independent nursing role while contributing to safe patient outcomes. © 2013 Blackwell Publishing Ltd.
Häsler, B; Stärk, K; Gottstein, B; Reist, M
2008-06-01
Neospora caninum is widely recognized as one of the most important abortifacients in cattle and causes substantial financial losses to bovine livestock production. This study aimed to calculate the losses caused by N. caninum on Swiss dairy farms and to evaluate the efficacy and profitability of the control strategies culling, not breeding replacements and chemotherapy of calves on farm level. Three different farm sizes with high, medium and low herd prevalences were defined. Epidemiological and financial models were used to simulate the effect of control strategies on the prevalence over time and to perform a cost-benefit analysis. The median annual losses on farm level ranged between CHF 3094.- (= Euro 1875; 60 dairy cattle, high prevalence) and CHF 134.- (= Euro 81; 15 dairy cattle, low prevalence). Culling of animals that had any abortion or a N. caninum abortion, or not breeding replacements from such animals, respectively, were neither effective nor profitable. Only the strategy "not breeding replacements from N. caninum seropositive cows" on farms with a high prevalence was financially attractive. The strategy "chemotherapy of calves" should be re-evaluated as soon as new data regarding the efficacy of treatment and a corresponding protocol have been scientifically validated.
A secure RFID-based WBAN for healthcare applications.
Ullah, Sana; Alamri, Atif
2013-10-01
A Wireless Body Area Network (WBAN) allows the seamless integration of small and intelligent invasive or non-invasive sensor nodes in, on or around a human body for continuous health monitoring. These nodes are expected to use different power-efficient protocols in order to extend the WBAN lifetime. This paper highlights the power consumption and security issues of WBAN for healthcare applications. Numerous power saving mechanisms are discussed and a secure RFID-based protocol for WBAN is proposed. The performance of the proposed protocol is analyzed and compared with that of IEEE 802.15.6-based CSMA/CA and preamble-based TDMA protocols using extensive simulations. It is shown that the proposed protocol is power-efficient and protects patients' data from adversaries. It is less vulnerable to different attacks compared to that of IEEE 802.15.6-based CSMA/CA and preamble-based TDMA protocols. For a low traffic load and a single alkaline battery of capacity 2.6 Ah, the proposed protocol could extend the WBAN lifetime, when deployed on patients in hospitals or at homes, to approximately five years.
Li-ion synaptic transistor for low power analog computing
Fuller, Elliot J.; Gabaly, Farid El; Leonard, Francois; ...
2016-11-22
Nonvolatile redox transistors (NVRTs) based upon Li-ion battery materials are demonstrated as memory elements for neuromorphic computer architectures with multi-level analog states, “write” linearity, low-voltage switching, and low power dissipation. Simulations of back propagation using the device properties reach ideal classification accuracy. Finally, physics-based simulations predict energy costs per “write” operation of <10 aJ when scaled to 200 nm × 200 nm.
Freebairn, L; Atkinson, J; Kelly, P; McDonnell, G; Rychetnik, L
2016-09-21
Evidence-informed decision-making is essential to ensure that health programs and services are effective and offer value for money; however, barriers to the use of evidence persist. Emerging systems science approaches and advances in technology are providing new methods and tools to facilitate evidence-based decision-making. Simulation modelling offers a unique tool for synthesising and leveraging existing evidence, data and expert local knowledge to examine, in a robust, low risk and low cost way, the likely impact of alternative policy and service provision scenarios. This case study will evaluate participatory simulation modelling to inform the prevention and management of gestational diabetes mellitus (GDM). The risks associated with GDM are well recognised; however, debate remains regarding diagnostic thresholds and whether screening and treatment to reduce maternal glucose levels reduce the associated risks. A diagnosis of GDM may provide a leverage point for multidisciplinary lifestyle modification interventions. This research will apply and evaluate a simulation modelling approach to understand the complex interrelation of factors that drive GDM rates, test options for screening and interventions, and optimise the use of evidence to inform policy and program decision-making. The study design will use mixed methods to achieve the objectives. Policy, clinical practice and research experts will work collaboratively to develop, test and validate a simulation model of GDM in the Australian Capital Territory (ACT). The model will be applied to support evidence-informed policy dialogues with diverse stakeholders for the management of GDM in the ACT. Qualitative methods will be used to evaluate simulation modelling as an evidence synthesis tool to support evidence-based decision-making. Interviews and analysis of workshop recordings will focus on the participants' engagement in the modelling process; perceived value of the participatory process, perceived commitment, influence and confidence of stakeholders in implementing policy and program decisions identified in the modelling process; and the impact of the process in terms of policy and program change. The study will generate empirical evidence on the feasibility and potential value of simulation modelling to support knowledge mobilisation and consensus building in health settings.
Towards a hybrid energy efficient multi-tree-based optimized routing protocol for wireless networks.
Mitton, Nathalie; Razafindralambo, Tahiry; Simplot-Ryl, David; Stojmenovic, Ivan
2012-12-13
This paper considers the problem of designing power efficient routing with guaranteed delivery for sensor networks with unknown geographic locations. We propose HECTOR, a hybrid energy efficient tree-based optimized routing protocol, based on two sets of virtual coordinates. One set is based on rooted tree coordinates, and the other is based on hop distances toward several landmarks. In HECTOR, the node currently holding the packet forwards it to its neighbor that optimizes ratio of power cost over distance progress with landmark coordinates, among nodes that reduce landmark coordinates and do not increase distance in tree coordinates. If such a node does not exist, then forwarding is made to the neighbor that reduces tree-based distance only and optimizes power cost over tree distance progress ratio. We theoretically prove the packet delivery and propose an extension based on the use of multiple trees. Our simulations show the superiority of our algorithm over existing alternatives while guaranteeing delivery, and only up to 30% additional power compared to centralized shortest weighted path algorithm.
Towards a Hybrid Energy Efficient Multi-Tree-Based Optimized Routing Protocol for Wireless Networks
Mitton, Nathalie; Razafindralambo, Tahiry; Simplot-Ryl, David; Stojmenovic, Ivan
2012-01-01
This paper considers the problem of designing power efficient routing with guaranteed delivery for sensor networks with unknown geographic locations. We propose HECTOR, a hybrid energy efficient tree-based optimized routing protocol, based on two sets of virtual coordinates. One set is based on rooted tree coordinates, and the other is based on hop distances toward several landmarks. In HECTOR, the node currently holding the packet forwards it to its neighbor that optimizes ratio of power cost over distance progress with landmark coordinates, among nodes that reduce landmark coordinates and do not increase distance in tree coordinates. If such a node does not exist, then forwarding is made to the neighbor that reduces tree-based distance only and optimizes power cost over tree distance progress ratio. We theoretically prove the packet delivery and propose an extension based on the use of multiple trees. Our simulations show the superiority of our algorithm over existing alternatives while guaranteeing delivery, and only up to 30% additional power compared to centralized shortest weighted path algorithm. PMID:23443398
A Low-Cost and Energy-Efficient Multiprocessor System-on-Chip for UWB MAC Layer
NASA Astrophysics Data System (ADS)
Xiao, Hao; Isshiki, Tsuyoshi; Khan, Arif Ullah; Li, Dongju; Kunieda, Hiroaki; Nakase, Yuko; Kimura, Sadahiro
Ultra-wideband (UWB) technology has attracted much attention recently due to its high data rate and low emission power. Its media access control (MAC) protocol, WiMedia MAC, promises a lot of facilities for high-speed and high-quality wireless communication. However, these benefits in turn involve a large amount of computational load, which challenges the traditional uniprocessor architecture based implementation method to provide the required performance. However, the constrained cost and power budget, on the other hand, makes using commercial multiprocessor solutions unrealistic. In this paper, a low-cost and energy-efficient multiprocessor system-on-chip (MPSoC), which tackles at once the aspects of system design, software migration and hardware architecture, is presented for the implementation of UWB MAC layer. Experimental results show that the proposed MPSoC, based on four simple RISC processors and shared-memory infrastructure, achieves up to 45% performance improvement and 65% power saving, but takes 15% less area than the uniprocessor implementation.
A study of low-cost, robust assistive listening system (ALS) based on digital wireless technology.
Israsena, P; Dubsok, P; Pan-Ngum, S
2008-11-01
We have developed a simple, low-cost digital wireless broadcasting system prototype, intended for a classroom of hearing impaired students. The system is designed to be a low-cost alternative to an existing FM system. The system implemented is for short-range communication, with a one-transmitter, multiple-receiver configuration, which is typical for these classrooms. The data is source-coded for voice-band quality, FSK modulated, and broadcasted via a 915 MHz radio frequency. A DES encryption can optionally be added for better information security. Test results show that the system operating range is approximately ten metres, and the sound quality is close to telephone quality as intended. We also discuss performance issues such as sound, power and size, as well as transmission protocols. The test results are the proof of concept that the prototype is a viable alternative to an existing FM system. Improvements can be made to the system's sound quality via techniques such as channel coding, which is also discussed.
Pharmacoeconomic comparison of Helicobacter pylori eradication regimens.
Sancar, Mesut; Izzettin, Fikret Vehbi; Apikoglu-Rabus, Sule; Besisik, Fatih; Tozun, Nurdan; Dulger, Gul
2006-08-01
Helicobacter pylori is the most important etiologic agent for development of peptic ulcer, chronic gastritis and gastric carcinomas. It is now well established that H. pylori eradication treatment is more cost-effective than acid suppressing therapies alone for the treatment of peptic ulcer disease. However, the comparative cost-effectiveness of various H. pylori eradication regimens is still not clear. This study was designed to make a pharmacoeconomic comparison of different H. pylori eradication regimens in patients with peptic ulcer disease or chronic gastritis, using real-world cost and effectiveness data. Istanbul University Hospital and Marmara University Hospital. A total of 75 patients diagnosed as H. pylori (+) by endoscopy were randomized to receive one of the seven H. pylori treatment protocols. These protocols were as follows: (LAC) = 'lansoprazole 30 mg bid + amoxicillin 1 g bid + clarithromycin 500 mg bid' for 7 days and (OCM) = 'omeprazole 20 mg bid + clarithromycin 250 mg bid + metronidazole 500 mg bid'; (OAM) = 'omeprazole 40 mg qd + amoxicillin 500 mg tid + metronidazole 500 mg tid'; (MARB) = 'metronidazole 250 mg tid + amoxicillin 500 mg qid + ranitidine 300 mg hs + bismuth 300 mg qid'; (OAC) = omeprazole 20 mg bid + amoxicillin 1 g bid + clarithromycin 500 mg bid'; (OCA) = omeprazole 40 mg bid + clarithromycin 500 mg bid + amoxicillin 1 g bid'; (OAB) = 'omeprazole 20 mg bid + amoxicillin 500 mg tid + bismuth 300 mg qid' each for 14 days. Only direct costs were included in the analysis. Effectiveness was measured in terms of "successful eradication". The cost-effectiveness ratios of the regimens were calculated using these effectiveness and cost data. The perspective of the study was assumed as the Government's perspective. Cost-effectiveness ratios of eradication regimens. MARB and OCA regimens were found to be more cost-effective than the other treatment regimens. The eradication rates and cost-effectiveness ratios calculated for these protocols were 90% (158.7 euros) for MARB and 90% (195.8 euros) for OCA regimen. This study confirms the importance of using local pharmacoeconomic data. Analyses such as this give decision-makers the tools to choose a better treatment option which is both highly effective yet and has a low cost.
ERIC Educational Resources Information Center
Ansaloni, Luca; Catena, Fausto; Coccolini, Frederico; Ceresoli, Marco; Pinna, Antonio Daniele
2014-01-01
Objectives: Inguinal canal anatomy and hernia repair is difficult for medical students and surgical residents to comprehend. Methods: Using low-cost material, a 3-dimensional inexpensive model of the inguinal canal was created to allow students to learn anatomical details and landmarks and to perform their own simulated hernia repair. In order to…
Two Hop Adaptive Vector Based Quality Forwarding for Void Hole Avoidance in Underwater WSNs
Javaid, Nadeem; Ahmed, Farwa; Wadud, Zahid; Alrajeh, Nabil; Alabed, Mohamad Souheil; Ilahi, Manzoor
2017-01-01
Underwater wireless sensor networks (UWSNs) facilitate a wide range of aquatic applications in various domains. However, the harsh underwater environment poses challenges like low bandwidth, long propagation delay, high bit error rate, high deployment cost, irregular topological structure, etc. Node mobility and the uneven distribution of sensor nodes create void holes in UWSNs. Void hole creation has become a critical issue in UWSNs, as it severely affects the network performance. Avoiding void hole creation benefits better coverage over an area, less energy consumption in the network and high throughput. For this purpose, minimization of void hole probability particularly in local sparse regions is focused on in this paper. The two-hop adaptive hop by hop vector-based forwarding (2hop-AHH-VBF) protocol aims to avoid the void hole with the help of two-hop neighbor node information. The other protocol, quality forwarding adaptive hop by hop vector-based forwarding (QF-AHH-VBF), selects an optimal forwarder based on the composite priority function. QF-AHH-VBF improves network good-put because of optimal forwarder selection. QF-AHH-VBF aims to reduce void hole probability by optimally selecting next hop forwarders. To attain better network performance, mathematical problem formulation based on linear programming is performed. Simulation results show that by opting these mechanisms, significant reduction in end-to-end delay and better throughput are achieved in the network. PMID:28763014
Two Hop Adaptive Vector Based Quality Forwarding for Void Hole Avoidance in Underwater WSNs.
Javaid, Nadeem; Ahmed, Farwa; Wadud, Zahid; Alrajeh, Nabil; Alabed, Mohamad Souheil; Ilahi, Manzoor
2017-08-01
Underwater wireless sensor networks (UWSNs) facilitate a wide range of aquatic applications in various domains. However, the harsh underwater environment poses challenges like low bandwidth, long propagation delay, high bit error rate, high deployment cost, irregular topological structure, etc. Node mobility and the uneven distribution of sensor nodes create void holes in UWSNs. Void hole creation has become a critical issue in UWSNs, as it severely affects the network performance. Avoiding void hole creation benefits better coverage over an area, less energy consumption in the network and high throughput. For this purpose, minimization of void hole probability particularly in local sparse regions is focused on in this paper. The two-hop adaptive hop by hop vector-based forwarding (2hop-AHH-VBF) protocol aims to avoid the void hole with the help of two-hop neighbor node information. The other protocol, quality forwarding adaptive hop by hop vector-based forwarding (QF-AHH-VBF), selects an optimal forwarder based on the composite priority function. QF-AHH-VBF improves network good-put because of optimal forwarder selection. QF-AHH-VBF aims to reduce void hole probability by optimally selecting next hop forwarders. To attain better network performance, mathematical problem formulation based on linear programming is performed. Simulation results show that by opting these mechanisms, significant reduction in end-to-end delay and better throughput are achieved in the network.
Acoustic Sensor Planning for Gunshot Location in National Parks: A Pareto Front Approach
González-Castaño, Francisco Javier; Alonso, Javier Vales; Costa-Montenegro, Enrique; López-Matencio, Pablo; Vicente-Carrasco, Francisco; Parrado-García, Francisco J.; Gil-Castiñeira, Felipe; Costas-Rodríguez, Sergio
2009-01-01
In this paper, we propose a solution for gunshot location in national parks. In Spain there are agencies such as SEPRONA that fight against poaching with considerable success. The DiANa project, which is endorsed by Cabaneros National Park and the SEPRONA service, proposes a system to automatically detect and locate gunshots. This work presents its technical aspects related to network design and planning. The system consists of a network of acoustic sensors that locate gunshots by hyperbolic multi-lateration estimation. The differences in sound time arrivals allow the computation of a low error estimator of gunshot location. The accuracy of this method depends on tight sensor clock synchronization, which an ad-hoc time synchronization protocol provides. On the other hand, since the areas under surveillance are wide, and electric power is scarce, it is necessary to maximize detection coverage and minimize system cost at the same time. Therefore, sensor network planning has two targets, i.e., coverage and cost. We model planning as an unconstrained problem with two objective functions. We determine a set of candidate solutions of interest by combining a derivative-free descent method we have recently proposed with a Pareto front approach. The results are clearly superior to random seeding in a realistic simulation scenario. PMID:22303135
Acoustic sensor planning for gunshot location in national parks: a pareto front approach.
González-Castaño, Francisco Javier; Alonso, Javier Vales; Costa-Montenegro, Enrique; López-Matencio, Pablo; Vicente-Carrasco, Francisco; Parrado-García, Francisco J; Gil-Castiñeira, Felipe; Costas-Rodríguez, Sergio
2009-01-01
In this paper, we propose a solution for gunshot location in national parks. In Spain there are agencies such as SEPRONA that fight against poaching with considerable success. The DiANa project, which is endorsed by Cabaneros National Park and the SEPRONA service, proposes a system to automatically detect and locate gunshots. This work presents its technical aspects related to network design and planning. The system consists of a network of acoustic sensors that locate gunshots by hyperbolic multi-lateration estimation. The differences in sound time arrivals allow the computation of a low error estimator of gunshot location. The accuracy of this method depends on tight sensor clock synchronization, which an ad-hoc time synchronization protocol provides. On the other hand, since the areas under surveillance are wide, and electric power is scarce, it is necessary to maximize detection coverage and minimize system cost at the same time. Therefore, sensor network planning has two targets, i.e., coverage and cost. We model planning as an unconstrained problem with two objective functions. We determine a set of candidate solutions of interest by combining a derivative-free descent method we have recently proposed with a Pareto front approach. The results are clearly superior to random seeding in a realistic simulation scenario.
Developing a protocol for creating microfluidic devices with a 3D printer, PDMS, and glass
NASA Astrophysics Data System (ADS)
Collette, Robyn; Novak, Eric; Shirk, Kathryn
2015-03-01
Microfluidics research requires the design and fabrication of devices that have the ability to manipulate small volumes of fluid, typically ranging from microliters to picoliters. These devices are used for a wide range of applications including the assembly of materials and testing of biological samples. Many methods have been previously developed to create microfluidic devices, including traditional nanolithography techniques. However, these traditional techniques are cost-prohibitive for many small-scale laboratories. This research explores a relatively low-cost technique using a 3D printed master, which is used as a template for the fabrication of polydimethylsiloxane (PDMS) microfluidic devices. The masters are designed using computer aided design (CAD) software and can be printed and modified relatively quickly. We have developed a protocol for creating simple microfluidic devices using a 3D printer and PDMS adhered to glass. This relatively simple and lower-cost technique can now be scaled to more complicated device designs and applications. Funding provided by the Undergraduate Research Grant Program at Shippensburg University and the Student/Faculty Research Engagement Grants from the College of Arts and Sciences at Shippensburg University.
2010-01-01
Background Regional generalized cost-effectiveness estimates of prevention, screening and treatment interventions for colorectal cancer are presented. Methods Standardised WHO-CHOICE methodology was used. A colorectal cancer model was employed to provide estimates of screening and treatment effectiveness. Intervention effectiveness was determined via a population state-transition model (PopMod) that simulates the evolution of a sub-regional population accounting for births, deaths and disease epidemiology. Economic costs of procedures and treatment were estimated, including programme overhead and training costs. Results In regions characterised by high income, low mortality and high existing treatment coverage, the addition of screening to the current high treatment levels is very cost-effective, although no particular intervention stands out in cost-effectiveness terms relative to the others. In regions characterised by low income, low mortality with existing treatment coverage around 50%, expanding treatment with or without screening is cost-effective or very cost-effective. Abandoning treatment in favour of screening (no treatment scenario) would not be cost effective. In regions characterised by low income, high mortality and low treatment levels, the most cost-effective intervention is expanding treatment. Conclusions From a cost-effectiveness standpoint, screening programmes should be expanded in developed regions and treatment programmes should be established for colorectal cancer in regions with low treatment coverage. PMID:20236531
2009-04-01
material design, complex oxide , UV photon irradiation 16. SECURITY CLASSIFICATION OF: 19a. NAME OF RESPONSIBLE PERSON Melanie W. Cole a. REPORT...1 1. Objective The objective of this effort was to develop a novel materials technology solution to achieve high-Q perovskite oxide thin...year 2008 (FY08) Director’s Research Initiative (DRI), we developed a post- growth ultraviolet (UV)- oxidation process science protocol to improve the
A simulator for surgery training: optimal sensory stimuli in a bone pinning simulation
NASA Astrophysics Data System (ADS)
Daenzer, Stefan; Fritzsche, Klaus
2008-03-01
Currently available low cost haptic devices allow inexpensive surgical training with no risk to patients. Major drawbacks of lower cost devices include limited maximum feedback force and the incapability to expose occurring moments. Aim of this work was the design and implementation of a surgical simulator that allows the evaluation of multi-sensory stimuli in order to overcome the occurring drawbacks. The simulator was built following a modular architecture to allow flexible combinations and thorough evaluation of different multi-sensory feedback modules. A Kirschner-Wire (K-Wire) tibial fracture fixation procedure was defined and implemented as a first test scenario. A set of computational metrics has been derived from the clinical requirements of the task to objectively assess the trainees performance during simulation. Sensory feedback modules for haptic and visual feedback have been developed, each in a basic and additionally in an enhanced form. First tests have shown that specific visual concepts can overcome some of the drawbacks coming along with low cost haptic devices. The simulator, the metrics and the surgery scenario together represent an important step towards a better understanding of the perception of multi-sensory feedback in complex surgical training tasks. Field studies on top of the architecture can open the way to risk-less and inexpensive surgical simulations that can keep up with traditional surgical training.
Imms, Christine; Chu, Eli Mang Yee; Guinea, Stephen; Sheppard, Loretta; Froude, Elspeth; Carter, Rob; Darzins, Susan; Ashby, Samantha; Gilbert-Hunt, Susan; Gribble, Nigel; Nicola-Richmond, Kelli; Penman, Merrolee; Gospodarevskaya, Elena; Mathieu, Erin; Symmons, Mark
2017-07-21
Clinical placements are a critical component of the training for health professionals such as occupational therapists. However, with growing student enrolments in professional education courses and workload pressures on practitioners, it is increasingly difficult to find sufficient, suitable placements that satisfy program accreditation requirements. The professional accrediting body for occupational therapy in Australia allows up to 200 of the mandatory 1000 clinical placement hours to be completed via simulation activities, but evidence of effectiveness and efficiency for student learning outcomes is lacking. Increasingly placement providers charge a fee to host students, leading educators to consider whether providing an internal program might be a feasible alternative for a portion of placement hours. Economic analysis of the incremental costs and benefits of providing a traditional versus simulated placement is required to inform decision-making. This study is a pragmatic, non-inferiority, single-blind, multicentre, two-group randomised controlled trial (RCT) with an embedded economic analysis. The RCT will compare a block of 40 hours of simulated placement (intervention) with a 40-hour block of traditional placement (comparator), with a focus on student learning outcomes and delivery costs. Six universities will instigate the educational intervention within their respective occupational therapy courses, randomly assigning their cohort of students (1:1 allocation) to the simulated or traditional clinical placements. The primary outcome is achievement of professional behaviours (e.g. communication, clinical reasoning) as assessed by a post-placement written examination. Secondary outcomes include proportions passing the placement assessed using the Student Practice Evaluation Form-Revised, changes in student confidence pre-/post-placement, student and educator evaluation of the placement experience and cost-effectiveness of simulated versus traditional clinical placements. Comprehensive cost data will be collected for both the simulated and traditional placement programs at each site for economic evaluation. Use of simulation in health-related fields like occupational therapy is common, but these activities usually relate to brief opportunities for isolated skill development. The simulated clinical placement evaluated in this trial is less common because it encapsulates a 5-day block of integrated activities, designed and delivered in a manner intended to emulate best-practice placement experiences. The planned study is rare due to inclusion of an economic analysis that aims to provide valuable information about the relationship between costs and outcomes across participating sites. Australian New Zealand Clinical Trials Registry, ACTRN12616001339448 . Registered 26 September 2016.
Low-Cost High-Speed Techniques for Real-Time Simulation of Power Electronic Systems
2007-06-01
first implemented on the RT-Lab using Simulink S- fuctions . An effort was then initiated to code at least part of the simulation on the available FPGA. It...time simulation, and the use of simulation packages such as Matlab and Spice. The primary purpose of these calculations was to confirm that the
NASA Astrophysics Data System (ADS)
Bylaska, Eric J.; Weare, Jonathan Q.; Weare, John H.
2013-08-01
Parallel in time simulation algorithms are presented and applied to conventional molecular dynamics (MD) and ab initio molecular dynamics (AIMD) models of realistic complexity. Assuming that a forward time integrator, f (e.g., Verlet algorithm), is available to propagate the system from time ti (trajectory positions and velocities xi = (ri, vi)) to time ti + 1 (xi + 1) by xi + 1 = fi(xi), the dynamics problem spanning an interval from t0…tM can be transformed into a root finding problem, F(X) = [xi - f(x(i - 1)]i = 1, M = 0, for the trajectory variables. The root finding problem is solved using a variety of root finding techniques, including quasi-Newton and preconditioned quasi-Newton schemes that are all unconditionally convergent. The algorithms are parallelized by assigning a processor to each time-step entry in the columns of F(X). The relation of this approach to other recently proposed parallel in time methods is discussed, and the effectiveness of various approaches to solving the root finding problem is tested. We demonstrate that more efficient dynamical models based on simplified interactions or coarsening time-steps provide preconditioners for the root finding problem. However, for MD and AIMD simulations, such preconditioners are not required to obtain reasonable convergence and their cost must be considered in the performance of the algorithm. The parallel in time algorithms developed are tested by applying them to MD and AIMD simulations of size and complexity similar to those encountered in present day applications. These include a 1000 Si atom MD simulation using Stillinger-Weber potentials, and a HCl + 4H2O AIMD simulation at the MP2 level. The maximum speedup (serial execution time/parallel execution time) obtained by parallelizing the Stillinger-Weber MD simulation was nearly 3.0. For the AIMD MP2 simulations, the algorithms achieved speedups of up to 14.3. The parallel in time algorithms can be implemented in a distributed computing environment using very slow transmission control protocol/Internet protocol networks. Scripts written in Python that make calls to a precompiled quantum chemistry package (NWChem) are demonstrated to provide an actual speedup of 8.2 for a 2.5 ps AIMD simulation of HCl + 4H2O at the MP2/6-31G* level. Implemented in this way these algorithms can be used for long time high-level AIMD simulations at a modest cost using machines connected by very slow networks such as WiFi, or in different time zones connected by the Internet. The algorithms can also be used with programs that are already parallel. Using these algorithms, we are able to reduce the cost of a MP2/6-311++G(2d,2p) simulation that had reached its maximum possible speedup in the parallelization of the electronic structure calculation from 32 s/time step to 6.9 s/time step.
Bylaska, Eric J; Weare, Jonathan Q; Weare, John H
2013-08-21
Parallel in time simulation algorithms are presented and applied to conventional molecular dynamics (MD) and ab initio molecular dynamics (AIMD) models of realistic complexity. Assuming that a forward time integrator, f (e.g., Verlet algorithm), is available to propagate the system from time ti (trajectory positions and velocities xi = (ri, vi)) to time ti + 1 (xi + 1) by xi + 1 = fi(xi), the dynamics problem spanning an interval from t0[ellipsis (horizontal)]tM can be transformed into a root finding problem, F(X) = [xi - f(x(i - 1)]i = 1, M = 0, for the trajectory variables. The root finding problem is solved using a variety of root finding techniques, including quasi-Newton and preconditioned quasi-Newton schemes that are all unconditionally convergent. The algorithms are parallelized by assigning a processor to each time-step entry in the columns of F(X). The relation of this approach to other recently proposed parallel in time methods is discussed, and the effectiveness of various approaches to solving the root finding problem is tested. We demonstrate that more efficient dynamical models based on simplified interactions or coarsening time-steps provide preconditioners for the root finding problem. However, for MD and AIMD simulations, such preconditioners are not required to obtain reasonable convergence and their cost must be considered in the performance of the algorithm. The parallel in time algorithms developed are tested by applying them to MD and AIMD simulations of size and complexity similar to those encountered in present day applications. These include a 1000 Si atom MD simulation using Stillinger-Weber potentials, and a HCl + 4H2O AIMD simulation at the MP2 level. The maximum speedup (serial execution/timeparallel execution time) obtained by parallelizing the Stillinger-Weber MD simulation was nearly 3.0. For the AIMD MP2 simulations, the algorithms achieved speedups of up to 14.3. The parallel in time algorithms can be implemented in a distributed computing environment using very slow transmission control protocol/Internet protocol networks. Scripts written in Python that make calls to a precompiled quantum chemistry package (NWChem) are demonstrated to provide an actual speedup of 8.2 for a 2.5 ps AIMD simulation of HCl + 4H2O at the MP2/6-31G* level. Implemented in this way these algorithms can be used for long time high-level AIMD simulations at a modest cost using machines connected by very slow networks such as WiFi, or in different time zones connected by the Internet. The algorithms can also be used with programs that are already parallel. Using these algorithms, we are able to reduce the cost of a MP2/6-311++G(2d,2p) simulation that had reached its maximum possible speedup in the parallelization of the electronic structure calculation from 32 s/time step to 6.9 s/time step.
NASA Astrophysics Data System (ADS)
Huang, Tielan; Wang, Yunpeng; Zhang, Jinlan
2017-07-01
In this study, simulation and evaluation of low impact development in resident district was carried out based on Storm Water Management Model (SWMM) and GIS method. In the evaluation model, we added 3 kinds of low impact development facilities, namely permeable pavement, rainwater garden, and green roof. These facilities are used alone or in combination. The model was run under five different rainfall reappearing periods. The simulation results using low impact development facilities were compared with simulation results under the current situation and undeveloped state. The results show that the total amount of runoff was greatly reduced by using various types of low impact development facilities in the urban residential district. The maximum reduction rate was using permeable pavement, reached 29.9%, followed was using rainwater garden, and the worst was using green roof. The lowest cost of reduction of the total amount of runoff was using permeable pavement, the followed was using rainwater garden, and the highest was using green roof. The combination scheme of various low impact development facilities has the highest efficiency of reducing total amount of runoff, and the lowest cost, which considering of the actual situation of the study area. The study indicated that application of low impact development facilities can reduce surface runoff effectively, which should be a useful way for prevention of urban waterlogging.
NASA Technical Reports Server (NTRS)
Eder, D.
1992-01-01
Parametric models were constructed for Earth-based laser powered electric orbit transfer from low Earth orbit to geosynchronous orbit. These models were used to carry out performance, cost/benefit, and sensitivity analyses of laser-powered transfer systems including end-to-end life cycle cost analyses for complete systems. Comparisons with conventional orbit transfer systems were made indicating large potential cost savings for laser-powered transfer. Approximate optimization was done to determine best parameter values for the systems. Orbit transfer flights simulations were conducted to explore effects of parameters not practical to model with a spreadsheet. The simulations considered view factors that determine when power can be transferred from ground stations to an orbit transfer vehicle and conducted sensitivity analyses for numbers of ground stations, Isp including dual-Isp transfers, and plane change profiles. Optimal steering laws were used for simultaneous altitude and plane change. Viewing geometry and low-thrust orbit raising were simultaneously simulated. A very preliminary investigation of relay mirrors was made.
Boutin, Alyssa; Blackman, Alison; O'Sullivan, David M; Forcello, Nicholas
2018-01-01
Background Rasburicase is a recombinant urate oxidase enzyme used for the treatment and prevention of tumor lysis syndrome. Our objective was to assess the efficacy of indication-based, low-dose rasburicase administration compared to the Food and Drug Administration-approved weight-based dosing. Methods This was a retrospective cohort study utilizing data from a tertiary medical center including patients admitted from 2012 to 2016, who received at least one dose of rasburicase. The primary outcome was achieving a uric acid level less than 7.5 mg/dl after a single dose of rasburicase in the preprotocol (Food and Drug Administration-approved weight-based dosing) and postprotocol (indication-based, low-dose) groups. Secondary outcomes included the change in uric acid levels between the pre- and postprotocol groups, adherence to the new institutional protocol, need for repeat rasburicase doses, and a cost analysis. Results Sixty-four patients received at least one dose of rasburicase between 1 January 2012 and 1 December 2016. Twenty-seven (79.4%) doses in the preprotocol group and 28 (82.4%) doses in the postprotocol group successfully achieved a uric acid level less than 7.5 mg/dl after a single dose of rasburicase (p=1.000). The average total monthly cost of rasburicase was reduced by 59.9% after adoption of the new protocol. Conclusions Indication-based, low-dose rasburicase displayed significantly more value when compared to weight-based dosing as shown by achieving cost savings without compromising clinical efficacy.
A new, ultra-low latency data transmission protocol for Earthquake Early Warning Systems
NASA Astrophysics Data System (ADS)
Hill, P.; Hicks, S. P.; McGowan, M.
2016-12-01
One measure used to assess the performance of Earthquake Early Warning Systems (EEWS) is the delay time between earthquake origin and issued alert. EEWS latency is dependent on a number of sources (e.g. P-wave propagation, digitisation, transmission, receiver processing, triggering, event declaration). Many regional seismic networks use the SEEDlink protocol; however, packet size is fixed to 512-byte miniSEED records, resulting in transmission latencies of >0.5 s. Data packetisation is seen as one of the main sources of delays in EEWS (Brown et al., 2011). Optimising data-logger and telemetry configurations is a cost-effective strategy to improve EEWS alert times (Behr et al., 2015). Digitisers with smaller, selectable packets can result in faster alerts (Sokos et al., 2016). We propose a new seismic protocol for regional seismic networks benefiting low-latency applications such as EEWS. The protocol, based on Güralp's existing GDI-link format is an efficient and flexible method to exchange data between seismic stations and data centers for a range of network configurations. The main principle is to stream data sample-by-sample instead of fixed-length packets to minimise transmission latency. Self-adaptive packetisation with compression maximises available telemetry bandwidth. Highly flexible metadata fields within GDI-link are compatible with existing miniSEED definitions. Data is sent as integers or floats, supporting a wide range of data formats, including discrete parameters such as Pd & τC for on-site earthquake early warning. Other advantages include: streaming station state-of-health information, instrument control, support of backfilling and fail-over strategies during telemetry outages. Based on tests carried out on the Güralp Minimus data-logger, we show our new protocol can reduce transmission latency to as low as 1 ms. The low-latency protocol is currently being implemented with common processing packages. The results of these tests will help to highlight latency levels that can be achieved with next-generation EEWS.
A Genetic Algorithm for the Generation of Packetization Masks for Robust Image Communication
Zapata-Quiñones, Katherine; Duran-Faundez, Cristian; Gutiérrez, Gilberto; Lecuire, Vincent; Arredondo-Flores, Christopher; Jara-Lipán, Hugo
2017-01-01
Image interleaving has proven to be an effective solution to provide the robustness of image communication systems when resource limitations make reliable protocols unsuitable (e.g., in wireless camera sensor networks); however, the search for optimal interleaving patterns is scarcely tackled in the literature. In 2008, Rombaut et al. presented an interesting approach introducing a packetization mask generator based in Simulated Annealing (SA), including a cost function, which allows assessing the suitability of a packetization pattern, avoiding extensive simulations. In this work, we present a complementary study about the non-trivial problem of generating optimal packetization patterns. We propose a genetic algorithm, as an alternative to the cited work, adopting the mentioned cost function, then comparing it to the SA approach and a torus automorphism interleaver. In addition, we engage the validation of the cost function and provide results attempting to conclude about its implication in the quality of reconstructed images. Several scenarios based on visual sensor networks applications were tested in a computer application. Results in terms of the selected cost function and image quality metric PSNR show that our algorithm presents similar results to the other approaches. Finally, we discuss the obtained results and comment about open research challenges. PMID:28452934
Chen, Xiao; Geng, Ling; Li, Hong
2014-04-01
To compare the clinical outcomes and cost-effectiveness of luteal phase down-regulation with gonadotrophin-releasing hormone (GnRH) agonist protocol and GnRH antagonist protocol in patients undergoing repeated in vitro fertilization and intracytoplasmic sperm injection (IVF-ICSI) cycles. A retrospective analysis of clinical outcomes and costs was conducted among 198 patients undergoing repeated IVF-ICSI cycles, including 109 receiving luteal phase down-regulation with GnRH agonist protocol (group A) and 89 receiving GnRH antagonist protocol (group B). The numbers of oocytes retrieved and good embryos, clinical pregnancy rate, abortion rate, the live birth rate, mean total cost, and the cost-effective ratio were compared between the two groups. In patients undergoing repeated IVF-ICSI cycles, the two protocols produced no significant differences in the number of good embryos, clinical pregnancy rate, abortion rate, or twin pregnancy rate. Compared with group B, group A had better clinical outcomes though this difference was not statistically significant. The number of retrieved oocytes was significantly greater and live birth rate significantly higher in group A than in group B (9.13=4.98 vs 7.11=4.74, and 20.2% vs 9.0%, respectively). Compared with group B, group A had higher mean total cost per cycle but lower costs for each oocyte retrieved (2729.11 vs 3038.60 RMB yuan), each good embryo (8867.19 vs 9644.85 RMB yuan), each clinical pregnancy (77598.06 vs 96139.85 RMB yuan). For patients undergoing repeated IVF/ICSI cycle, luteal phase down-regulation with GnRH agonist protocol produces good clinical outcomes with also good cost-effectiveness in spite an unsatisfactory ovarian reserve.
Zhang, Chao; Yin, An-Xiang; Jiang, Ruibin; Rong, Jie; Dong, Lu; Zhao, Tian; Sun, Ling-Dong; Wang, Jianfang; Chen, Xing; Yan, Chun-Hua
2013-05-28
Food safety is a constant concern for humans. Besides adulteration and contamination, another major threat comes from the spontaneous spoilage of perishable products, which is basically inevitable and highly dependent on the temperature history during the custody chain. For advanced quality control and assessment, time-temperature indicators (TTIs) can be deployed to document the temperature history. However, the use of TTIs is currently limited by either relatively high cost or poor programmability. Here we describe a general, kinetically programmable, and cost-efficient TTI protocol constructed from plasmonic nanocrystals. We present proof-of-principle demonstrations that our TTI can be specifically tailored and thus used to track perishables, dynamically mimic the deteriorative processes therein, and indicate product quality through sharp-contrast multicolor changes. The flexible programmability of our TTI, combined with its substantially low cost and low toxicity, promises a general applicability to each single packaged item of a plethora of perishable products.
PM2.5 monitoring system based on ZigBee wireless sensor network
NASA Astrophysics Data System (ADS)
Lin, Lukai; Li, Xiangshun; Gu, Weiying
2017-06-01
In the view of the haze problem, aiming at improving the deficiency of the traditional PM2.5 monitoring methods, such as the insufficient real-time monitoring, limited transmission distance, high cost and the difficulty to maintain, the atmosphere PM2.5 monitoring system based on ZigBee technology is designed. The system combines the advantages of ZigBee’s low cost, low power consumption, high reliability and GPRS/Internet’s capability of remote transmission of data. Furthermore, it adopts TI’s Z-Stack protocol stack, and selects CC2530 chip and TI’s MSP430 microcontroller as the core, which establishes the air pollution monitoring network that is helpful for the early prediction of major air pollution disasters.
Meng, Yilin; Roux, Benoît
2015-08-11
The weighted histogram analysis method (WHAM) is a standard protocol for postprocessing the information from biased umbrella sampling simulations to construct the potential of mean force with respect to a set of order parameters. By virtue of the WHAM equations, the unbiased density of state is determined by satisfying a self-consistent condition through an iterative procedure. While the method works very effectively when the number of order parameters is small, its computational cost grows rapidly in higher dimension. Here, we present a simple and efficient alternative strategy, which avoids solving the self-consistent WHAM equations iteratively. An efficient multivariate linear regression framework is utilized to link the biased probability densities of individual umbrella windows and yield an unbiased global free energy landscape in the space of order parameters. It is demonstrated with practical examples that free energy landscapes that are comparable in accuracy to WHAM can be generated at a small fraction of the cost.
2015-01-01
The weighted histogram analysis method (WHAM) is a standard protocol for postprocessing the information from biased umbrella sampling simulations to construct the potential of mean force with respect to a set of order parameters. By virtue of the WHAM equations, the unbiased density of state is determined by satisfying a self-consistent condition through an iterative procedure. While the method works very effectively when the number of order parameters is small, its computational cost grows rapidly in higher dimension. Here, we present a simple and efficient alternative strategy, which avoids solving the self-consistent WHAM equations iteratively. An efficient multivariate linear regression framework is utilized to link the biased probability densities of individual umbrella windows and yield an unbiased global free energy landscape in the space of order parameters. It is demonstrated with practical examples that free energy landscapes that are comparable in accuracy to WHAM can be generated at a small fraction of the cost. PMID:26574437
A DSMC Study of Low Pressure Argon Discharge
NASA Astrophysics Data System (ADS)
Hash, David; Meyyappan, M.
1997-10-01
Work toward a self-consistent plasma simulation using the DSMC method for examination of the flowfields of low-pressure high density plasma reactors is presented. Presently, DSMC simulations for these applications involve either treating the electrons as a fluid or imposing experimentally determined values for the electron number density profile. In either approach, the electrons themselves are not physically simulated. Self-consistent plasma DSMC simulations have been conducted for aerospace applications but at a severe computational cost due in part to the scalar architectures on which the codes were employed. The present work attempts to conduct such simulations at a more reasonable cost using a plasma version of the object-oriented parallel Cornell DSMC code, MONACO, on an IBM SP-2. Due the availability of experimental data, the GEC reference cell is chosen to conduct preliminary investigations. An argon discharge is examined thus affording a simple chemistry set with eight gas-phase reactions and five species: Ar, Ar^+, Ar^*, Ar_2, and e where Ar^* is a metastable.
Mashiko, Toshihiro; Otani, Keisuke; Kawano, Ryutaro; Konno, Takehiko; Kaneko, Naoki; Ito, Yumiko; Watanabe, Eiju
2015-03-01
We developed a method for fabricating a three-dimensional hollow and elastic aneurysm model useful for surgical simulation and surgical training. In this article, we explain the hollow elastic model prototyping method and report on the effects of applying it to presurgical simulation and surgical training. A three-dimensional printer using acrylonitrile-butadiene-styrene as a modeling material was used to produce a vessel model. The prototype was then coated with liquid silicone. After the silicone had hardened, the acrylonitrile-butadiene-styrene was melted with xylene and removed, leaving an outer layer as a hollow elastic model. Simulations using the hollow elastic model were performed in 12 patients. In all patients, the clipping proceeded as scheduled. The surgeon's postoperative assessment was favorable in all cases. This method enables easy fabrication at low cost. Simulation using the hollow elastic model is thought to be useful for understanding of three-dimensional aneurysm structure. Copyright © 2015 Elsevier Inc. All rights reserved.
Situational Awareness from a Low-Cost Camera System
NASA Technical Reports Server (NTRS)
Freudinger, Lawrence C.; Ward, David; Lesage, John
2010-01-01
A method gathers scene information from a low-cost camera system. Existing surveillance systems using sufficient cameras for continuous coverage of a large field necessarily generate enormous amounts of raw data. Digitizing and channeling that data to a central computer and processing it in real time is difficult when using low-cost, commercially available components. A newly developed system is located on a combined power and data wire to form a string-of-lights camera system. Each camera is accessible through this network interface using standard TCP/IP networking protocols. The cameras more closely resemble cell-phone cameras than traditional security camera systems. Processing capabilities are built directly onto the camera backplane, which helps maintain a low cost. The low power requirements of each camera allow the creation of a single imaging system comprising over 100 cameras. Each camera has built-in processing capabilities to detect events and cooperatively share this information with neighboring cameras. The location of the event is reported to the host computer in Cartesian coordinates computed from data correlation across multiple cameras. In this way, events in the field of view can present low-bandwidth information to the host rather than high-bandwidth bitmap data constantly being generated by the cameras. This approach offers greater flexibility than conventional systems, without compromising performance through using many small, low-cost cameras with overlapping fields of view. This means significant increased viewing without ignoring surveillance areas, which can occur when pan, tilt, and zoom cameras look away. Additionally, due to the sharing of a single cable for power and data, the installation costs are lower. The technology is targeted toward 3D scene extraction and automatic target tracking for military and commercial applications. Security systems and environmental/ vehicular monitoring systems are also potential applications.
Considerations for Multiprocessor Topologies
NASA Technical Reports Server (NTRS)
Byrd, Gregory T.; Delagi, Bruce A.
1987-01-01
Choosing a multiprocessor interconnection topology may depend on high-level considerations, such as the intended application domain and the expected number of processors. It certainly depends on low-level implementation details, such as packaging and communications protocols. The authors first use rough measures of cost and performance to characterize several topologies. They then examine how implementation details can affect the realizable performance of a topology.
A decentralized software bus based on IP multicas ting
NASA Technical Reports Server (NTRS)
Callahan, John R.; Montgomery, Todd
1995-01-01
We describe decentralized reconfigurable implementation of a conference management system based on the low-level Internet Protocol (IP) multicasting protocol. IP multicasting allows low-cost, world-wide, two-way transmission of data between large numbers of conferencing participants through the Multicasting Backbone (MBone). Each conference is structured as a software bus -- a messaging system that provides a run-time interconnection model that acts as a separate agent (i.e., the bus) for routing, queuing, and delivering messages between distributed programs. Unlike the client-server interconnection model, the software bus model provides a level of indirection that enhances the flexibility and reconfigurability of a distributed system. Current software bus implementations like POLYLITH, however, rely on a centralized bus process and point-to-point protocols (i.e., TCP/IP) to route, queue, and deliver messages. We implement a software bus called the MULTIBUS that relies on a separate process only for routing and uses a reliable IP multicasting protocol for delivery of messages. The use of multicasting means that interconnections are independent of IP machine addresses. This approach allows reconfiguration of bus participants during system execution without notifying other participants of new IP addresses. The use of IP multicasting also permits an economy of scale in the number of participants. We describe the MULITIBUS protocol elements and show how our implementation performs better than centralized bus implementations.
Terris-Prestholt, Fern; Vyas, Seema; Kumaranayake, Lilani; Mayaud, Philippe; Watts, Charlotte
2006-10-01
Calls for increased investment in sexually transmitted infection (STI) treatment across the developing world have been made to address the high disease burden and the association with HIV transmission. The goals of this study were to systematically review evidence on the cost of treating curable STIs and to explore its key determinants. A search of published literature was conducted in PubMed and supplemented by reviews of gray literature. Studies were analyzed by broad focus. Regression analysis explored how intervention characteristics affect unit costs, accounting for differences in costing methods. Fifty-three primary studies were identified, of which 62% used empirical data, 35% presented economic costs, and 22% presented full costs. The median STI treatment cost was US dollars 17.80. Clinics serving symptomatic patients were consistently cheaper than outreach services, services using syndromic management protocols had lower costs, and unit costs decreased with scale. The compiled cost data provide an evidence base that can be used to help inform resource planning.
Duvall, W Lane; Savino, John A; Levine, Elliot J; Hermann, Luke K; Croft, Lori B; Henzlova, Milena J
2015-02-01
Previous literature suggests that myocardial perfusion imaging (MPI) adds little to the prognosis of patients who exercise >10 metabolic equivalents (METs) during stress testing. With this in mind, we prospectively tested a provisional injection protocol in emergency department (ED) patients presenting for the evaluation of chest pain in which a patient would not receive an injection of radioisotope if adequate exercise was achieved without symptoms and a negative ECG response. All patients who presented to the ED over a 5-year period who were referred for stress testing as part of their ED evaluation were included. Patients considered for a provisional protocol were: exercise stress, age <65 years, no known coronary artery disease, and an interpretable rest ECG. Criteria for not injecting included a maximal predicted heart rate ≥85%, ≥10 METs of exercise, no anginal symptoms during stress, and no ECG changes. Groups were compared based on stress test results, all-cause and cardiac mortality, follow-up cardiac testing, subsequent revascularization, and cost. A total of 965 patients were eligible with 192 undergoing exercise-only and 773 having perfusion imaging. After 41.6 ± 19.6 months of follow-up, all-cause mortality was similar in the exercise-only versus the exercise plus imaging group (2.6% vs. 2.1%, p = 0.59). There were no cardiac deaths in the exercise-only group. At 1 year there was no difference in the number of repeat functional stress tests (1.6% vs. 2.1%, p = 0.43), fewer angiograms (0% vs. 4.0%, p = 0.002), and a significantly lower cost ($65 ± $332 vs $506 ± $1,991, p = 0.002; values are in US dollars) in the exercise-only group. The radiation exposure in the exercise plus imaging group was 8.4 ± 2.1 mSv. A provisional injection protocol has a very low mortality, few follow-up diagnostic tests, and lower cost compared to standard imaging protocols. If adopted it would decrease radiation exposure, save time and decrease health-care costs without jeopardizing prognosis.
Network simulation-based optimization of centrifugo-pneumatic blood plasma separation
Zehnle, S.; Zengerle, R.; von Stetten, F.; Paust, N.
2017-01-01
Automated and robust separation of 14 μl of plasma from 40 μl of whole blood at a purity of 99.81% ± 0.11% within 43 s is demonstrated for the hematocrit range of 20%–60% in a centrifugal microfluidic polymer disk. At high rotational frequency, red blood cells (RBCs) within whole blood are concentrated in a radial outer RBC collection chamber. Simultaneously, plasma is concentrated in a radial inner pneumatic chamber, where a defined air volume is enclosed and compressed. Subsequent reduction of the rotational frequency to not lower than 25 Hz enables rapid transfer of supernatant plasma into a plasma collection chamber, with highly suppressed resuspension of red blood cells. Disk design and the rotational protocol are optimized to make the process fast, robust, and insusceptible for undesired cell resuspension. Numerical network simulation with lumped model elements is used to predict and optimize the fluidic characteristics. Lysis of the remaining red blood cells in the purified plasma, followed by measurement of the hemoglobin concentration, was used to determine plasma purity. Due to the pneumatic actuation, no surface treatment of the fluidic cartridge or any additional external means are required, offering the possibility for low-cost mass fabrication technologies, such as injection molding or thermoforming. PMID:28798850
An energy-efficient data gathering protocol in large wireless sensor network
NASA Astrophysics Data System (ADS)
Wang, Yamin; Zhang, Ruihua; Tao, Shizhong
2006-11-01
Wireless sensor network consisting of a large number of small sensors with low-power transceiver can be an effective tool for gathering data in a variety of environment. The collected data must be transmitted to the base station for further processing. Since a network consists of sensors with limited battery energy, the method for data gathering and routing must be energy efficient in order to prolong the lifetime of the network. In this paper, we presented an energy-efficient data gathering protocol in wireless sensor network. The new protocol used data fusion technology clusters nodes into groups and builds a chain among the cluster heads according to a hybrid of the residual energy and distance to the base station. Results in stochastic geometry are used to derive the optimum parameter of our algorithm that minimizes the total energy spent in the network. Simulation results show performance superiority of the new protocol.
NASA Astrophysics Data System (ADS)
Thangavelautham, J.; Asphaug, E.; Schwartz, S.
2017-02-01
Our work has identified the use of on-orbit centrifuge science laboratories as a key enabler towards low-cost, fast-track physical simulation of off-world environments for future planetary science missions.
The cost of conservative synchronization in parallel discrete event simulations
NASA Technical Reports Server (NTRS)
Nicol, David M.
1990-01-01
The performance of a synchronous conservative parallel discrete-event simulation protocol is analyzed. The class of simulation models considered is oriented around a physical domain and possesses a limited ability to predict future behavior. A stochastic model is used to show that as the volume of simulation activity in the model increases relative to a fixed architecture, the complexity of the average per-event overhead due to synchronization, event list manipulation, lookahead calculations, and processor idle time approach the complexity of the average per-event overhead of a serial simulation. The method is therefore within a constant factor of optimal. The analysis demonstrates that on large problems--those for which parallel processing is ideally suited--there is often enough parallel workload so that processors are not usually idle. The viability of the method is also demonstrated empirically, showing how good performance is achieved on large problems using a thirty-two node Intel iPSC/2 distributed memory multiprocessor.
Low-resolution simulations of vesicle suspensions in 2D
NASA Astrophysics Data System (ADS)
Kabacaoğlu, Gökberk; Quaife, Bryan; Biros, George
2018-03-01
Vesicle suspensions appear in many biological and industrial applications. These suspensions are characterized by rich and complex dynamics of vesicles due to their interaction with the bulk fluid, and their large deformations and nonlinear elastic properties. Many existing state-of-the-art numerical schemes can resolve such complex vesicle flows. However, even when using provably optimal algorithms, these simulations can be computationally expensive, especially for suspensions with a large number of vesicles. These high computational costs can limit the use of simulations for parameter exploration, optimization, or uncertainty quantification. One way to reduce the cost is to use low-resolution discretizations in space and time. However, it is well-known that simply reducing the resolution results in vesicle collisions, numerical instabilities, and often in erroneous results. In this paper, we investigate the effect of a number of algorithmic empirical fixes (which are commonly used by many groups) in an attempt to make low-resolution simulations more stable and more predictive. Based on our empirical studies for a number of flow configurations, we propose a scheme that attempts to integrate these fixes in a systematic way. This low-resolution scheme is an extension of our previous work [51,53]. Our low-resolution correction algorithms (LRCA) include anti-aliasing and membrane reparametrization for avoiding spurious oscillations in vesicles' membranes, adaptive time stepping and a repulsion force for handling vesicle collisions and, correction of vesicles' area and arc-length for maintaining physical vesicle shapes. We perform a systematic error analysis by comparing the low-resolution simulations of dilute and dense suspensions with their high-fidelity, fully resolved, counterparts. We observe that the LRCA enables both efficient and statistically accurate low-resolution simulations of vesicle suspensions, while it can be 10× to 100× faster.
Binary processing and display concepts for low-cost Omega receivers. [airborne systems simulation
NASA Technical Reports Server (NTRS)
Lilley, R. W.
1974-01-01
A description is given of concepts related to plans for developing a low-cost, all-digital Omega receiver capable of offering to the small-aircraft pilot a reliable and accurate navigation aid. The receiver base considered includes a receiver front-end module, a receiver control module, a memory-aided phase-locked loop module, a housekeeping timer module, and a synthesizer module.
Evaluation of a low-cost, 3D-printed model for bronchoscopy training.
Parotto, Matteo; Jiansen, Joshua Qua; AboTaiban, Ahmed; Ioukhova, Svetlana; Agzamov, Alisher; Cooper, Richard; O'Leary, Gerald; Meineri, Massimiliano
2017-01-01
Flexible bronchoscopy is a fundamental procedure in anaesthesia and critical care medicine. Although learning this procedure is a complex task, the use of simulation-based training provides significant advantages, such as enhanced patient safety. Access to bronchoscopy simulators may be limited in low-resource settings. We have developed a low-cost 3D-printed bronchoscopy training model. A parametric airway model was obtained from an online medical model repository and fabricated using a low-cost 3D printer. The participating physicians had no prior bronchoscopy experience. Participants received a 30-minute lecture on flexible bronchoscopy and were administered a 15-item pre-test questionnaire on bronchoscopy. Afterwards, participants were instructed to perform a series of predetermined bronchoscopy tasks on the 3D printed simulator on 4 consecutive occasions. The time needed to perform the tasks and the quality of task performance (identification of bronchial anatomy, technique, dexterity, lack of trauma) were recorded. Upon completion of the simulator tests, participants were administered the 15-item questionnaire (post-test) once again. Participant satisfaction data on the perceived usefulness and accuracy of the 3D model were collected. A statistical analysis was performed using the t-test. Data are reported as mean values (± standard deviation). The time needed to complete all tasks was 152.9 ± 71.5 sec on the 1st attempt vs. 98.7 ± 40.3 sec on the 4th attempt (P = 0.03). Likewise, the quality of performance score improved from 8.3 ± 6.7 to 18.2 ± 2.5 (P < 0.0001). The average number of correct answers in the questionnaire was 6.8 ± 1.9 pre-test and 13.3 ± 3.1 post-test (P < 0.0001). Participants reported a high level of satisfaction with the perceived usefulness and accuracy of the model. We developed a 3D-printed model for bronchoscopy training. This model improved trainee performance and may represent a valid, low-cost bronchoscopy training tool.
NASA Technical Reports Server (NTRS)
Rash, James; Parise, Ron; Hogie, Keith; Criscuolo, Ed; Langston, Jim; Jackson, Chris; Price, Harold; Powers, Edward I. (Technical Monitor)
2000-01-01
The Operating Missions as Nodes on the Internet (OMNI) project at NASA's Goddard Space flight Center (GSFC), is demonstrating the use of standard Internet protocols for spacecraft communication systems. This year, demonstrations of Internet access to a flying spacecraft have been performed with the UoSAT-12 spacecraft owned and operated by Surrey Satellite Technology Ltd. (SSTL). Previously, demonstrations were performed using a ground satellite simulator and NASA's Tracking and Data Relay Satellite System (TDRSS). These activities are part of NASA's Space Operations Management Office (SOMO) Technology Program, The work is focused on defining the communication architecture for future NASA missions to support both NASA's "faster, better, cheaper" concept and to enable new types of collaborative science. The use of standard Internet communication technology for spacecraft simplifies design, supports initial integration and test across an IP based network, and enables direct communication between scientists and instruments as well as between different spacecraft, The most recent demonstrations consisted of uploading an Internet Protocol (IP) software stack to the UoSAT- 12 spacecraft, simple modifications to the SSTL ground station, and a series of tests to measure performance of various Internet applications. The spacecraft was reconfigured on orbit at very low cost. The total period between concept and the first tests was only 3 months. The tests included basic network connectivity (PING), automated clock synchronization (NTP), and reliable file transfers (FTP). Future tests are planned to include additional protocols such as Mobile IP, e-mail, and virtual private networks (VPN) to enable automated, operational spacecraft communication networks. The work performed and results of the initial phase of tests are summarized in this paper. This work is funded and directed by NASA/GSFC with technical leadership by CSC in arrangement with SSTL, and Vytek Wireless.
Whole-Genome Sequencing and Assembly with High-Throughput, Short-Read Technologies
Sundquist, Andreas; Ronaghi, Mostafa; Tang, Haixu; Pevzner, Pavel; Batzoglou, Serafim
2007-01-01
While recently developed short-read sequencing technologies may dramatically reduce the sequencing cost and eventually achieve the $1000 goal for re-sequencing, their limitations prevent the de novo sequencing of eukaryotic genomes with the standard shotgun sequencing protocol. We present SHRAP (SHort Read Assembly Protocol), a sequencing protocol and assembly methodology that utilizes high-throughput short-read technologies. We describe a variation on hierarchical sequencing with two crucial differences: (1) we select a clone library from the genome randomly rather than as a tiling path and (2) we sample clones from the genome at high coverage and reads from the clones at low coverage. We assume that 200 bp read lengths with a 1% error rate and inexpensive random fragment cloning on whole mammalian genomes is feasible. Our assembly methodology is based on first ordering the clones and subsequently performing read assembly in three stages: (1) local assemblies of regions significantly smaller than a clone size, (2) clone-sized assemblies of the results of stage 1, and (3) chromosome-sized assemblies. By aggressively localizing the assembly problem during the first stage, our method succeeds in assembling short, unpaired reads sampled from repetitive genomes. We tested our assembler using simulated reads from D. melanogaster and human chromosomes 1, 11, and 21, and produced assemblies with large sets of contiguous sequence and a misassembly rate comparable to other draft assemblies. Tested on D. melanogaster and the entire human genome, our clone-ordering method produces accurate maps, thereby localizing fragment assembly and enabling the parallelization of the subsequent steps of our pipeline. Thus, we have demonstrated that truly inexpensive de novo sequencing of mammalian genomes will soon be possible with high-throughput, short-read technologies using our methodology. PMID:17534434
Blanchette, Marc-André; Bussières, André; Stochkendahl, Mette Jensen; Boruff, Jill; Harrison, Pamela
2015-03-18
Chiropractic care is a common treatment for low back pain (LBP). Previous studies have failed to clarify the relative cost-effectiveness of chiropractic care in comparison with other commonly used approaches because previous attempts to synthetize the economic literature has only included partial economic evaluations. The objective of this project is to estimate the clinical effectiveness and cost-effectiveness of chiropractic care compared to other commonly used care approaches among adult patients with non-specific LBP. Two systematic reviews will be conducted to identify 1) randomized controlled trials and 2) full economic evaluations of chiropractic care for low back pain compared to standard care provided by other healthcare providers. We will conduct searches in specialized electronic databases for randomized controlled trials and full economic evaluations published between 1990 and 2014 using a combination of keywords and MeSH terms. This will be supplemented by a search of the gray literature. Citations, abstracts, and relevant papers will be screened for eligibility by two reviewers independently. Studies will be critically appraised using 1) the Cochrane risk of bias tool and 2) the Drummond (BMJ) checklist. Results will be summarized using Slavin's qualitative best-evidence synthesis approach. Data relating to the primary outcomes of the effectiveness study will be evaluated for inclusion in meta-analyses. The costs will be standardized to the same currency (USD) and adjusted to the same year for inflation. The incremental cost-effectiveness, incremental net benefit, and relevant confidant intervals will be recalculated in order to facilitate comparison between studies. Our review will evaluate both the clinical effectiveness and the cost-effectiveness associated with chiropractic care for LBP. A more precise estimate of the cost-effectiveness of chiropractic care for LBP relative to other forms of conservative care is needed for decision-makers and third-party payers to offer best care options for LBP. Our results will facilitate evidence-based management of patients with LBP and identify key areas for future research. The protocol is registered on PROSPERO ( CRD42014008746 ).
de Muinck, Eric J; Trosvik, Pål; Gilfillan, Gregor D; Hov, Johannes R; Sundaram, Arvind Y M
2017-07-06
Advances in sequencing technologies and bioinformatics have made the analysis of microbial communities almost routine. Nonetheless, the need remains to improve on the techniques used for gathering such data, including increasing throughput while lowering cost and benchmarking the techniques so that potential sources of bias can be better characterized. We present a triple-index amplicon sequencing strategy to sequence large numbers of samples at significantly lower c ost and in a shorter timeframe compared to existing methods. The design employs a two-stage PCR protocol, incorpo rating three barcodes to each sample, with the possibility to add a fourth-index. It also includes heterogeneity spacers to overcome low complexity issues faced when sequencing amplicons on Illumina platforms. The library preparation method was extensively benchmarked through analysis of a mock community in order to assess biases introduced by sample indexing, number of PCR cycles, and template concentration. We further evaluated the method through re-sequencing of a standardized environmental sample. Finally, we evaluated our protocol on a set of fecal samples from a small cohort of healthy adults, demonstrating good performance in a realistic experimental setting. Between-sample variation was mainly related to batch effects, such as DNA extraction, while sample indexing was also a significant source of bias. PCR cycle number strongly influenced chimera formation and affected relative abundance estimates of species with high GC content. Libraries were sequenced using the Illumina HiSeq and MiSeq platforms to demonstrate that this protocol is highly scalable to sequence thousands of samples at a very low cost. Here, we provide the most comprehensive study of performance and bias inherent to a 16S rRNA gene amplicon sequencing method to date. Triple-indexing greatly reduces the number of long custom DNA oligos required for library preparation, while the inclusion of variable length heterogeneity spacers minimizes the need for PhiX spike-in. This design results in a significant cost reduction of highly multiplexed amplicon sequencing. The biases we characterize highlight the need for highly standardized protocols. Reassuringly, we find that the biological signal is a far stronger structuring factor than the various sources of bias.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y; Zhang, J; Hu, Q
2014-06-01
Purpose: To investigate the possibility of applying optimized scanning protocols for pediatric CT simulation by quantifying the dosimetric inaccuracy introduced by using a fixed HU to density conversion. Methods: The images of a CIRS electron density reference phantom (Model 062) were acquired by a Siemens CT simulator (Sensation Open) using the following settings of tube voltage and beam current: 120 kV/190mA (the reference protocol used to calibrate CT for our treatment planning system (TPS)); Fixed 190mA combined with all available kV: 80, 100, and 140; fixed 120 kV and various current from 37 to 444 mA (scanner extremes) with intervalmore » of 30 mA. To avoid the HU uncertainty of point sampling in the various inserts of known electron densities, the mean CT numbers of the central cylindrical volume were calculated using DICOMan software. The doses per 100 MU to the reference point (SAD=100cm, Depth=10cm, Field=10X10cm, 6MV photon beam) in a virtual cubic phantom (30X30X30cm) were calculated using Eclipse TPS (calculation model: AcurosXB-11031) by assigning the CT numbers to HU of typical materials acquired by various protocols. Results: For the inserts of densities less than muscle, CT number fluctuations of all protocols were within the tolerance of 10 HU as accepted by AAPM-TG66. For more condensed materials, fixed kV yielded stable HU with any mA combination where largest disparities were found in 1750mg/cc insert: HU{sub reference}=1801(106.6cGy), HU{sub minimum}=1799 (106.6cGy, error{sub dose}=0.00%), HU{sub maximum}=1815 (106.8cGy, error{sub dose}=0.19%). Yet greater disagreements were observed with increasing density when kV was modified: HU{sub minimum}=1646 (104.5cGy, error{sub dose}=- 1.97%), HU{sub maximum}=2487 (116.4cGy, error{sub dose}=9.19%) in 1750mg/cc insert. Conclusion: Without affecting treatment dose calculation, personalized mA optimization of CT simulator can be conducted by fixing kV for a better cost-effectiveness of imaging dose and quality especially for children. Unless recalibrated, kV should be constant for all anatomical sites if diagnostic CT scanner is used as a simulator. This work was partially supported by Capital Medical Development Scientific Research Fund of China.« less
Cacades: A reliable dissemination protocol for data collection sensor network
Peng, Y.; Song, W.; Huang, R.; Xu, M.; Shirazi, B.; LaHusen, R.; Pei, G.
2009-01-01
In this paper, we propose a fast and reliable data dissemination protocol Cascades to disseminate data from the sink(base station) to all or a subset of nodes in a data collection sensor network. Cascades makes use of the parentmonitor-children analogy to ensure reliable dissemination. Each node monitors whether or not its children have received the broadcast messages through snooping children's rebroadcasts or waiting for explicit ACKs. If a node detects a gap in its message sequences, it can fetch the missing messages from its neighbours reactively. Cascades also considers many practical issues for field deployment, such as dynamic topology, link/node failure, etc.. It therefore guarantees that a disseminated message from the sink will reach all intended receivers and the dissemination is terminated in a short time period. Notice that, all existing dissemination protocols either do not guarantee reliability or do not terminate [1, 2], which does not meet the requirement of real-time command control. We conducted experiment evaluations in both TOSSIM simulator and a sensor network testbed to compare Cascades with those existing dissemination protocols in TinyOS sensor networks, which show that Cascades achieves a higher degree of reliability, lower communication cost, and less delivery delay. ??2009 IEEE.
Reconfigurable routing protocol for free space optical sensor networks.
Xie, Rong; Yang, Won-Hyuk; Kim, Young-Chon
2012-01-01
Recently, free space optical sensor networks (FSOSNs), which are based on free space optics (FSO) instead of radio frequency (RF), have gained increasing visibility over traditional wireless sensor networks (WSNs) due to their advantages such as larger capacity, higher security, and lower cost. However, the performance of FSOSNs is restricted to the requirement of a direct line-of-sight (LOS) path between a sender and a receiver pair. Once a node dies of energy depletion, the network would probably suffer from a dramatic decrease of connectivity, resulting in a huge loss of data packets. Thus, this paper proposes a reconfigurable routing protocol (RRP) to overcome this problem by dynamically reconfiguring the network virtual topology. The RRP works in three phases: (1) virtual topology construction, (2) routing establishment, and (3) reconfigurable routing. When data transmission begins, the data packets are first routed through the shortest hop paths. Then a reconfiguration is initiated by the node whose residual energy falls below a threshold. Nodes affected by this dying node are classified into two types, namely maintenance nodes and adjustment nodes, and they are reconfigured according to the types. An energy model is designed to evaluate the performance of RRP through OPNET simulation. Our simulation results indicate that the RRP achieves better performance compared with the simple-link protocol and a direct reconfiguration scheme in terms of connectivity, network lifetime, packet delivery ratio and the number of living nodes.
Hu, Miao; Zhong, Zhangdui; Ni, Minming; Baiocchi, Andrea
2016-11-01
Large volume content dissemination is pursued by the growing number of high quality applications for Vehicular Ad hoc NETworks(VANETs), e.g., the live road surveillance service and the video-based overtaking assistant service. For the highly dynamical vehicular network topology, beacon-less routing protocols have been proven to be efficient in achieving a balance between the system performance and the control overhead. However, to the authors' best knowledge, the routing design for large volume content has not been well considered in the previous work, which will introduce new challenges, e.g., the enhanced connectivity requirement for a radio link. In this paper, a link Lifetime-aware Beacon-less Routing Protocol (LBRP) is designed for large volume content delivery in VANETs. Each vehicle makes the forwarding decision based on the message header information and its current state, including the speed and position information. A semi-Markov process analytical model is proposed to evaluate the expected delay in constructing one routing path for LBRP. Simulations show that the proposed LBRP scheme outperforms the traditional dissemination protocols in providing a low end-to-end delay. The analytical model is shown to exhibit a good match on the delay estimation with Monte Carlo simulations, as well.
Hu, Miao; Zhong, Zhangdui; Ni, Minming; Baiocchi, Andrea
2016-01-01
Large volume content dissemination is pursued by the growing number of high quality applications for Vehicular Ad hoc NETworks(VANETs), e.g., the live road surveillance service and the video-based overtaking assistant service. For the highly dynamical vehicular network topology, beacon-less routing protocols have been proven to be efficient in achieving a balance between the system performance and the control overhead. However, to the authors’ best knowledge, the routing design for large volume content has not been well considered in the previous work, which will introduce new challenges, e.g., the enhanced connectivity requirement for a radio link. In this paper, a link Lifetime-aware Beacon-less Routing Protocol (LBRP) is designed for large volume content delivery in VANETs. Each vehicle makes the forwarding decision based on the message header information and its current state, including the speed and position information. A semi-Markov process analytical model is proposed to evaluate the expected delay in constructing one routing path for LBRP. Simulations show that the proposed LBRP scheme outperforms the traditional dissemination protocols in providing a low end-to-end delay. The analytical model is shown to exhibit a good match on the delay estimation with Monte Carlo simulations, as well. PMID:27809285
A comparison of two emergency medical dispatch protocols with respect to accuracy.
Torlén, Klara; Kurland, Lisa; Castrén, Maaret; Olanders, Knut; Bohm, Katarina
2017-12-29
Emergency medical dispatching should be as accurate as possible in order to ensure patient safety and optimize the use of ambulance resources. This study aimed to compare the accuracy, measured as priority level, between two Swedish dispatch protocols - the three-graded priority protocol Medical Index and a newly developed prototype, the four-graded priority protocol, RETTS-A. A simulation study was carried out at the Emergency Medical Communication Centre (EMCC) in Stockholm, Sweden, between October and March 2016. Fifty-three voluntary telecommunicators working at SOS Alarm were recruited nationally. Each telecommunicator handled 26 emergency medical calls, simulated by experienced standard patients. Manuscripts for the scenarios were based on recorded real-life calls, representing the six most common complaints. A cross-over design with 13 + 13 calls was used. Priority level and medical condition for each scenario was set through expert consensus and used as gold standard in the study. A total of 1293 calls were included in the analysis. For priority level, n = 349 (54.0%) of the calls were assessed correctly with Medical Index and n = 309 (48.0%) with RETTS-A (p = 0.012). Sensitivity for the highest priority level was 82.6% (95% confidence interval: 76.6-87.3%) in the Medical Index and 54.0% (44.3-63.4%) in RETTS-A. Overtriage was 37.9% (34.2-41.7%) in the Medical Index and 28.6% (25.2-32.2%) in RETTS-A. The corresponding proportion of undertriage was 6.3% (4.7-8.5%) and 23.4% (20.3-26.9%) respectively. In this simulation study we demonstrate that Medical Index had a higher accuracy for priority level and less undertriage than the new prototype RETTS-A. The overall accuracy of both protocols is to be considered as low. Overtriage challenges resource utilization while undertriage threatens patient safety. The results suggest that in order to improve patient safety both protocols need revisions in order to guarantee safe emergency medical dispatching.
Cislan-2 extension final document by University of Twente (Netherlands)
NASA Astrophysics Data System (ADS)
Niemegeers, Ignas; Baumann, Frank; Beuwer, Wim; Jordense, Marcel; Pras, Aiko; Schutte, Leon; Tracey, Ian
1992-01-01
Results of worked performed under the so called Cislan extension contract are presented. The adaptation of the Cislan 2 prototype design to an environment of interconnected Local Area Networks (LAN's) instead of a single 802.5 token ring LAN is considered. In order to extend the network architecture, the Interconnection Function (IF) protocol layer was subdivided into two protocol layers: a new IF layer, and below the Medium Enhancement (ME) protocol layer. Some small enhancements to the distributed bandwidth allocation protocol were developed, which in fact are also applicable to the 'normal' Cislan 2 system. The new services and protocols are described together with some scenarios and requirements for the new internetting Cislan 2 system. How to overcome the degradation of the quality of speech due to packet loss on the LAN subsystem was studied. Experiments were planned in order to measure this speech quality degradation. Simulations were performed of two Cislan subsystems, the bandwidth allocation protocol and the clock synchronization mechanism. Results on both simulations, performed on SUN workstations using QNAP as a simulation tool, are given. Results of the simulations of the clock synchronization mechanism, and results of the simulation of the distributed bandwidth allocation protocol are given.
Project ITCH: Interactive Digital Simulation in Electrical Engineering Education.
ERIC Educational Resources Information Center
Bailey, F. N.; Kain, R. Y.
A two-stage project is investigating the educational potential of a low-cost time-sharing system used as a simulation tool in Electrical Engineering (EE) education. Phase I involves a pilot study and Phase II a full integration. The system employs interactive computer simulation to teach engineering concepts which are not well handled by…
Generalized Maintenance Trainer Simulator: Development of Hardware and Software. Final Report.
ERIC Educational Resources Information Center
Towne, Douglas M.; Munro, Allen
A general purpose maintenance trainer, which has the potential to simulate a wide variety of electronic equipments without hardware changes or new computer programs, has been developed and field tested by the Navy. Based on a previous laboratory model, the Generalized Maintenance Trainer Simulator (GMTS) is a relatively low cost trainer that…
MicroSensors Systems: detection of a dismounted threat
NASA Astrophysics Data System (ADS)
Davis, Bill; Berglund, Victor; Falkofske, Dwight; Krantz, Brian
2005-05-01
The Micro Sensor System (MSS) is a layered sensor network with the goal of detecting dismounted threats approaching high value assets. A low power unattended ground sensor network is dependant on a network protocol for efficiency in order to minimize data transmissions after network establishment. The reduction of network 'chattiness' is a primary driver for minimizing power consumption and is a factor in establishing a low probability of detection and interception. The MSS has developed a unique protocol to meet these challenges. Unattended ground sensor systems are most likely dependant on batteries for power which due to size determines the ability of the sensor to be concealed after placement. To minimize power requirements, overcome size limitations, and maintain a low system cost the MSS utilizes advanced manufacturing processes know as Fluidic Self-Assembly and Chip Scale Packaging. The type of sensing element and the ability to sense various phenomenologies (particularly magnetic) at ranges greater than a few meters limits the effectiveness of a system. The MicroSensor System will overcome these limitations by deploying large numbers of low cost sensors, which is made possible by the advanced manufacturing process used in production of the sensors. The MSS program will provide unprecedented levels of real-time battlefield information which greatly enhances combat situational awareness when integrated with the existing Command, Control, Communications, Computers, Intelligence, Surveillance and Reconnaissance (C4ISR) infrastructure. This system will provide an important boost to realizing the information dominant, network-centric objective of Joint Vision 2020.
Borrás-Blasco, Joaquín; Casterá, M Dolores-Elvira; Cortes, Xavier; Rosique-Robles, J Dolores; Abad, F Javier
2014-11-01
Until 2010 the cost of biological treatments in Rheumatoid Arthritis (RA) was increasing annually by 15% in our hospital. In 1st January 2011, a Hospital Commission of Biological Therapies involving rheumatology and pharmacy services was created to improve the management of biological drugs and a biological therapy prioritization protocol in RA patients was also established to improve the efficient usage of biological drugs in RA. To evaluate the economic impact associated with a biological therapy prioritization protocol for RA patients in the Hospital of Sagunto. Observational, ambispective study comparing the associated cost of RA patients treated with biological drugs in the pre-protocol (2009 - 2010) versus post-protocol periods (2011 - 2012). RA patients treated with Abatacept (ABA), Adalimumab (ADA), Etanercept (ETN) or Infliximab (IFX) for at least 6 months during the study period (2009 - 2012) were included. In 2012, Tocilizumab (TCZ) was also included in the prioritization protocol. Prioritization protocol was established based on both clinical and economical aspects and supervised case by case by our Commission. Cost savings and economic impact were calculated using Spanish official prices. In the pre-protocol period (2009 - 2010), total expenses were increasing by €110,000, up to €1,761,000 in 2010 (€11,362 pat/year). After protocol implementation, total expenses decreased by 53,676€ on the 2010 - 2011 period, and 149,200€ on the 2011 - 2012 period. On the 2010 - 2011 period the cost of biological therapy per patient-year decreased 355€ (11,007€ pat/year) and additional 653€ (up to 10,354€ pat/year) by 2012, with a cumulative effect of the protocol implementation of 1,008€ per patient-year. In the pre-protocol period (2009), the annual cost/patient was 10.812€ with ETN, 10.942€ with IFX, 12.961€ with ADA and 12.739€ with ABA. By 1st January 2013, the annual cost per patient was 9,469€ with ETN, 10,579€ with IFX, 11,117€ with ADA, 13,540€ with ABA and 14,932€ with TCZ. The creation of our Commission of Biological Therapies is key to rational management of RA patients and optimization of resources, allowing us to save 200,000€ after 2-year efficiency protocol implementation.
Prospects of e-beam evaporated molybdenum oxide as a hole transport layer for perovskite solar cells
NASA Astrophysics Data System (ADS)
Ali, F.; Khoshsirat, N.; Duffin, J. L.; Wang, H.; Ostrikov, K.; Bell, J. M.; Tesfamichael, T.
2017-09-01
Perovskite solar cells have emerged as one of the most efficient and low cost technologies for delivering of solar electricity due to their exceptional optical and electrical properties. Commercialization of the perovskite solar cells is, however, limited because of the higher cost and environmentally sensitive organic hole transport materials such as spiro-OMETAD and PEDOT:PSS. In this study, an empirical simulation was performed using the Solar Cell Capacitance Simulator software to explore the MoOx thin film as an alternative hole transport material for perovskite solar cells. In the simulation, properties of MoOx thin films deposited by the electron beam evaporation technique from high purity (99.99%) MoO3 pellets at different substrate temperatures (room temperature, 100 °C and 200 °C) were used as input parameters. The films were highly transparent (>80%) and have low surface roughness (≤2 nm) with bandgap energy ranging between 3.75 eV and 3.45 eV. Device simulation has shown that the MoOx deposited at room temperature can work in both the regular and inverted structures of the perovskite solar cell with a promising efficiency of 18.25%. Manufacturing of the full device is planned in order to utilize the MoOx as an alternative hole transport material for improved performance, good stability, and low cost of the perovskite solar cell.
Congestion control and routing over satellite networks
NASA Astrophysics Data System (ADS)
Cao, Jinhua
Satellite networks and transmissions find their application in fields of computer communications, telephone communications, television broadcasting, transportation, space situational awareness systems and so on. This thesis mainly focuses on two networking issues affecting satellite networking: network congestion control and network routing optimization. Congestion, which leads to long queueing delays, packet losses or both, is a networking problem that has drawn the attention of many researchers. The goal of congestion control mechanisms is to ensure high bandwidth utilization while avoiding network congestion by regulating the rate at which traffic sources inject packets into a network. In this thesis, we propose a stable congestion controller using data-driven, safe switching control theory to improve the dynamic performance of satellite Transmission Control Protocol/Active Queue Management (TCP/AQM) networks. First, the stable region of the Proportional-Integral (PI) parameters for a nominal model is explored. Then, a PI controller, whose parameters are adaptively tuned by switching among members of a given candidate set, using observed plant data, is presented and compared with some classical AQM policy examples, such as Random Early Detection (RED) and fixed PI control. A new cost detectable switching law with an interval cost function switching algorithm, which improves the performance and also saves the computational cost, is developed and compared with a law commonly used in the switching control literature. Finite-gain stability of the system is proved. A fuzzy logic PI controller is incorporated as a special candidate to achieve good performance at all nominal points with the available set of candidate controllers. Simulations are presented to validate the theory. An effocient routing algorithm plays a key role in optimizing network resources. In this thesis, we briefly analyze Low Earth Orbit (LEO) satellite networks, review the Cross Entropy (CE) method and then develop a novel on-demand routing system named Cross Entropy Accelerated Ant Routing System (CEAARS) for regular constellation LEO satellite networks. By implementing simulations on an Iridium-like satellite network, we compare the proposed CEAARS algorithm with the two approaches to adaptive routing protocols on the Internet: distance-vector (DV) and link-state (LS), as well as with the original Cross Entropy Ant Routing System (CEARS). DV algorithms are based on distributed Bellman Ford algorithm, and LS algorithms are implementation of Dijkstras single source shortest path. The results show that CEAARS not only remarkably improves the convergence speed of achieving optimal or suboptimal paths, but also reduces the number of overhead ants (management packets).
Delay Tolerant Networking - Bundle Protocol Simulation
NASA Technical Reports Server (NTRS)
SeGui, John; Jenning, Esther
2006-01-01
In this paper, we report on the addition of MACHETE models needed to support DTN, namely: the Bundle Protocol (BP) model. To illustrate the useof MACHETE with the additional DTN model, we provide an example simulation to benchmark its performance. We demonstrate the use of the DTN protocol and discuss statistics gathered concerning the total time needed to simulate numerous bundle transmissions.
NASA Astrophysics Data System (ADS)
Magazzù, G.; Borgese, G.; Costantino, N.; Fanucci, L.; Incandela, J.; Saponara, S.
2013-02-01
In many research fields as high energy physics (HEP), astrophysics, nuclear medicine or space engineering with harsh operating conditions, the use of fast and flexible digital communication protocols is becoming more and more important. The possibility to have a smart and tested top-down design flow for the design of a new protocol for control/readout of front-end electronics is very useful. To this aim, and to reduce development time, costs and risks, this paper describes an innovative design/verification flow applied as example case study to a new communication protocol called FF-LYNX. After the description of the main FF-LYNX features, the paper presents: the definition of a parametric SystemC-based Integrated Simulation Environment (ISE) for high-level protocol definition and validation; the set up of figure of merits to drive the design space exploration; the use of ISE for early analysis of the achievable performances when adopting the new communication protocol and its interfaces for a new (or upgraded) physics experiment; the design of VHDL IP cores for the TX and RX protocol interfaces; their implementation on a FPGA-based emulator for functional verification and finally the modification of the FPGA-based emulator for testing the ASIC chipset which implements the rad-tolerant protocol interfaces. For every step, significant results will be shown to underline the usefulness of this design and verification approach that can be applied to any new digital protocol development for smart detectors in physics experiments.
Low cost training aids and devices
NASA Technical Reports Server (NTRS)
Lawver, J.; Lee, A.
1984-01-01
The need for advanced flight simulators for two engine aircraft is discussed. Cost effectiveness is a major requirement. Other training aids available for increased effectiveness are recommended. Training aids include: (1) audio-visual slides; (2) information transfer; (3) programmed instruction; and (4) interactive training systems.
Automatic CT simulation optimization for radiation therapy: A general strategy.
Li, Hua; Yu, Lifeng; Anastasio, Mark A; Chen, Hsin-Chen; Tan, Jun; Gay, Hiram; Michalski, Jeff M; Low, Daniel A; Mutic, Sasa
2014-03-01
In radiation therapy, x-ray computed tomography (CT) simulation protocol specifications should be driven by the treatment planning requirements in lieu of duplicating diagnostic CT screening protocols. The purpose of this study was to develop a general strategy that allows for automatically, prospectively, and objectively determining the optimal patient-specific CT simulation protocols based on radiation-therapy goals, namely, maintenance of contouring quality and integrity while minimizing patient CT simulation dose. The authors proposed a general prediction strategy that provides automatic optimal CT simulation protocol selection as a function of patient size and treatment planning task. The optimal protocol is the one that delivers the minimum dose required to provide a CT simulation scan that yields accurate contours. Accurate treatment plans depend on accurate contours in order to conform the dose to actual tumor and normal organ positions. An image quality index, defined to characterize how simulation scan quality affects contour delineation, was developed and used to benchmark the contouring accuracy and treatment plan quality within the predication strategy. A clinical workflow was developed to select the optimal CT simulation protocols incorporating patient size, target delineation, and radiation dose efficiency. An experimental study using an anthropomorphic pelvis phantom with added-bolus layers was used to demonstrate how the proposed prediction strategy could be implemented and how the optimal CT simulation protocols could be selected for prostate cancer patients based on patient size and treatment planning task. Clinical IMRT prostate treatment plans for seven CT scans with varied image quality indices were separately optimized and compared to verify the trace of target and organ dosimetry coverage. Based on the phantom study, the optimal image quality index for accurate manual prostate contouring was 4.4. The optimal tube potentials for patient sizes of 38, 43, 48, 53, and 58 cm were 120, 140, 140, 140, and 140 kVp, respectively, and the corresponding minimum CTDIvol for achieving the optimal image quality index 4.4 were 9.8, 32.2, 100.9, 241.4, and 274.1 mGy, respectively. For patients with lateral sizes of 43-58 cm, 120-kVp scan protocols yielded up to 165% greater radiation dose relative to 140-kVp protocols, and 140-kVp protocols always yielded a greater image quality index compared to the same dose-level 120-kVp protocols. The trace of target and organ dosimetry coverage and the γ passing rates of seven IMRT dose distribution pairs indicated the feasibility of the proposed image quality index for the predication strategy. A general strategy to predict the optimal CT simulation protocols in a flexible and quantitative way was developed that takes into account patient size, treatment planning task, and radiation dose. The experimental study indicated that the optimal CT simulation protocol and the corresponding radiation dose varied significantly for different patient sizes, contouring accuracy, and radiation treatment planning tasks.
Silicon material task. Part 3: Low-cost silicon solar array project
NASA Technical Reports Server (NTRS)
Roques, R. A.; Coldwell, D. M.
1977-01-01
The feasibility of a process for carbon reduction of low impurity silica in a plasma heat source was investigated to produce low-cost solar-grade silicon. Theoretical aspects of the reaction chemistry were studied with the aid of a computer program using iterative free energy minimization. These calculations indicate a threshold temperature exists at 2400 K below which no silicon is formed. The computer simulation technique of molecular dynamics was used to study the quenching of product species.
Clinical results of computerized tomography-based simulation with laser patient marking.
Ragan, D P; Forman, J D; He, T; Mesina, C F
1996-02-01
Accuracy of a patient treatment portal marking device and computerized tomography (CT) simulation have been clinically tested. A CT-based simulator has been assembled based on a commercial CT scanner. This includes visualization software and a computer-controlled laser drawing device. This laser drawing device is used to transfer the setup, central axis, and/or radiation portals from the CT simulator to the patient for appropriate patient skin marking. A protocol for clinical testing is reported. Twenty-five prospectively, sequentially accessioned patients have been analyzed. The simulation process can be completed in an average time of 62 min. Under many cases, the treatment portals can be designed and the patient marked in one session. Mechanical accuracy of the system was found to be within +/- 1mm. The portal projection accuracy in clinical cases is observed to be better than +/- 1.2 mm. Operating costs are equivalent to the conventional simulation process it replaces. Computed tomography simulation is a clinical accurate substitute for conventional simulation when used with an appropriate patient marking system and digitally reconstructed radiographs. Personnel time spent in CT simulation is equivalent to time in conventional simulation.
A Low Cost Concept for Data Acquisition Systems Applied to Decentralized Renewable Energy Plants
Jucá, Sandro C. S.; Carvalho, Paulo C. M.; Brito, Fábio T.
2011-01-01
The present paper describes experiences of the use of monitoring and data acquisition systems (DAS) and proposes a new concept of a low cost DAS applied to decentralized renewable energy (RE) plants with an USB interface. The use of such systems contributes to disseminate these plants, recognizing in real time local energy resources, monitoring energy conversion efficiency and sending information concerning failures. These aspects are important, mainly for developing countries, where decentralized power plants based on renewable sources are in some cases the best option for supplying electricity to rural areas. Nevertheless, the cost of commercial DAS is still a barrier for a greater dissemination of such systems in developing countries. The proposed USB based DAS presents a new dual clock operation philosophy, in which the acquisition system contains two clock sources for parallel information processing from different communication protocols. To ensure the low cost of the DAS and to promote the dissemination of this technology in developing countries, the proposed data acquisition firmware and the software for USB microcontrollers programming is a free and open source software, executable in the Linux and Windows® operating systems. PMID:22346600
A low cost concept for data acquisition systems applied to decentralized renewable energy plants.
Jucá, Sandro C S; Carvalho, Paulo C M; Brito, Fábio T
2011-01-01
The present paper describes experiences of the use of monitoring and data acquisition systems (DAS) and proposes a new concept of a low cost DAS applied to decentralized renewable energy (RE) plants with an USB interface. The use of such systems contributes to disseminate these plants, recognizing in real time local energy resources, monitoring energy conversion efficiency and sending information concerning failures. These aspects are important, mainly for developing countries, where decentralized power plants based on renewable sources are in some cases the best option for supplying electricity to rural areas. Nevertheless, the cost of commercial DAS is still a barrier for a greater dissemination of such systems in developing countries. The proposed USB based DAS presents a new dual clock operation philosophy, in which the acquisition system contains two clock sources for parallel information processing from different communication protocols. To ensure the low cost of the DAS and to promote the dissemination of this technology in developing countries, the proposed data acquisition firmware and the software for USB microcontrollers programming is a free and open source software, executable in the Linux and Windows® operating systems.
Hall, Gordon H; Sloan, David L; Ma, Tianchi; Couse, Madeline H; Martel, Stephane; Elliott, Duncan G; Glerum, D Moira; Backhouse, Christopher J
2014-07-04
Electrophoresis is an integral part of many molecular diagnostics protocols and an inexpensive implementation would greatly facilitate point-of-care (POC) applications. However, the high instrumentation cost presents a substantial barrier, much of it associated with fluorescence detection. The cost of such systems could be substantially reduced by placing the fluidic channel and photodiode directly above the detector in order to collect a larger portion of the fluorescent light. In future, this could be achieved through the integration and monolithic fabrication of photoresist microchannels on complementary metal-oxide semiconductor microelectronics (CMOS). However, the development of such a device is expensive due to high non-recurring engineering costs. To facilitate that development, we present a system that utilises an optical relay to integrate low-cost polymeric microfluidics with a CMOS chip that provides a photodiode, analog-digital conversion and a standard serial communication interface. This system embodies an intermediate level of microelectronic integration, and significantly decreases development costs. With a limit of detection of 1.3±0.4nM of fluorescently end-labeled deoxyribonucleic acid (DNA), it is suitable for diagnostic applications. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Heath, Bruce E.; Khan, M. Javed; Rossi, Marcia; Ali, Syed Firasat
2005-01-01
The rising cost of flight training and the low cost of powerful computers have resulted in increasing use of PC-based flight simulators. This has prompted FAA standards regulating such use and allowing aspects of training on simulators meeting these standards to be substituted for flight time. However, the FAA regulations require an authorized flight instructor as part of the training environment. Thus, while costs associated with flight time have been reduced, the cost associated with the need for a flight instructor still remains. The obvious area of research, therefore, has been to develop intelligent simulators. However, the two main challenges of such attempts have been training strategies and assessment. The research reported in this paper was conducted to evaluate various performance metrics of a straight-in landing approach by 33 novice pilots flying a light single engine aircraft simulation. These metrics were compared to assessments of these flights by two flight instructors to establish a correlation between the two techniques in an attempt to determine a composite performance metric for this flight maneuver.
Law, Martin; Ma, Wang-Kei; Lau, Damian; Cheung, Kenneth; Ip, Janice; Yip, Lawrance; Lam, Wendy
2018-04-01
To evaluate and to obtain analytic formulation for the calculation of the effective dose and associated cancer risk using the EOS microdose protocol for scoliotic pediatric patients undergoing full spine imaging at different age of exposure; to demonstrate the microdose protocol capable of delivering lesser radiation dose and hence of further reducing cancer risk induction when compared with the EOS low dose protocol; to obtain cumulative effective dose and cancer risk for both genders scoliotic pediatrics of US and Hong Kong population using the microdose protocol. Organ absorbed doses of full spine exposed scoliotic pediatric patients have been simulated with the use of EOS microdose protocol imaging parameters input to the Monte Carlo software PCXMC. Gender and age specific effective dose has been calculated with the simulated organ absorbed dose using the ICRP-103 approach. The associated radiation induced cancer risk, expressed as lifetime attributable risk (LAR), has been estimated according to the method introduced in the Biological Effects of Ionizing Radiation VII report. Values of LAR have been estimated for scoliotic patients exposed repetitively during their follow up period at different age for US and Hong Kong population. The effective doses of full spine imaging with simultaneous posteroanterior and lateral projection for patients exposed at the age between 5 and 18 years using the EOS microdose protocol have been calculated within the range of 2.54-14.75 μSv. The corresponding LAR for US and Hong Kong population was ranged between 0.04 × 10 -6 and 0.84 × 10 -6 . Cumulative effective dose and cancer risk during follow-up period can be estimated using the results and are of information to patients and their parents. With the use of computer simulation and analytic formulation, we obtained the cumulative effective dose and cancer risk at any age of exposure for pediatric patients of US and Hong Kong population undergoing repetitive microdose protocol full spine imaging. Girls would be at a statistically significant higher cumulative cancer risk than boys undergoing the same microdose full spine imaging protocol and the same follow-up schedule. Copyright © 2018 Elsevier B.V. All rights reserved.
Clinical Simulation: A Protocol for Evaluation of Mobile Technology.
Mather, Carey; Jensen, Sanne; Cummings, Elizabeth
2017-01-01
For mobile technology to be accepted at point of care in healthcare environments there is a need to demonstrate benefits whilst ameliorating the risks and challenges. To provide a standardised approach to evaluation of mobile technology a simulation protocol was developed to provide guidance for its use in healthcare environments. Simulated conditions provide the opportunity to assess intended and unintended consequences and identify potential workarounds when using technology. The protocol can also be used to demonstrate the importance of the development of digital professionalism by end-users prior to students entering the clinical practice setting. The mobile technology protocol was adapted from a health information systems protocol developed and used at the ITX Lab, Denmark for use in other simulation laboratories. Use case scenarios were developed to enable evaluation of mobile technology for mobile learning of nurses, nurse supervisors, students and patients. The scenarios can be used in a range of simulated environments including hospital bedside, outpatient clinic or community settings. A case study exemplar of a nurse and patient is included to demonstrate how the mobile technology protocol can be applied.
[Cost-effectiveness of hepatitis C treatment in slow virologic responders coinfected with HIV].
Rodrigues, Marcus Paulo da Silva; Vianna, Cid Manso de Mello; Mosegui, Gabriela Bittencourt Gonzalez; Costa e Silva, Frances Valéria; Peregrino, Antonio Augusto de Freitas; Jardim, Fernando Nagib
2013-11-01
Recent evidence has demonstrated that slow responders may benefit from antiviral treatment in HCV/HIV coinfection. This study aimed to evaluate the cost-effectiveness of HCV treatment in individuals with genotype 1 coinfected with HIV, with peg-interferon in combination with ribavirin, compared to the inclusion (versus non-inclusion) of slow responders. A Markov model was developed that simulated the progression of liver disease in a hypothetical cohort of one thousand men over 40 years of age, considering the Brazilian Unified National Health System (SUS) perspective and a 30-year timeline. The extension of treatment to slow responders provided a 60% increase in the number of individuals who eliminated HCV and an incremental cost-effectiveness ratio of 44,171 BRL/QALY, below the acceptability threshold proposed by World Health Organization. Sensitivity analysis did not alter the results. The inclusion of HCV/ HIV-coinfected slow virologic responders in the treatment protocol is shown to be a cost-effective strategy for the SUS.
A modified error correction protocol for CCITT signalling system no. 7 on satellite links
NASA Astrophysics Data System (ADS)
Kreuer, Dieter; Quernheim, Ulrich
1991-10-01
Comite Consultatif International des Telegraphe et Telephone (CCITT) Signalling System No. 7 (SS7) provides a level 2 error correction protocol particularly suited for links with propagation delays higher than 15 ms. Not being originally designed for satellite links, however, the so called Preventive Cyclic Retransmission (PCR) Method only performs well on satellite channels when traffic is low. A modified level 2 error control protocol, termed Fix Delay Retransmission (FDR) method is suggested which performs better at high loads, thus providing a more efficient use of the limited carrier capacity. Both the PCR and the FDR methods are investigated by means of simulation and results concerning throughput, queueing delay, and system delay, respectively. The FDR method exhibits higher capacity and shorter delay than the PCR method.
Potential of Sub-GHz Wireless for Future IoT Wearables and Design of Compact 915 MHz Antenna
Di Serio, Adolfo; Barton, John; Rodencal, Matthew; Dunlop, Gary; O’Flynn, Brendan
2017-01-01
Internet of Things (IoT) technology is rapidly emerging in medical applications as it offers the possibility of lower-cost personalized healthcare monitoring. At the present time, the 2.45 GHz band is in widespread use for these applications but in this paper, the authors investigate the potential of the 915 MHz ISM band in implementing future, wearable IoT devices. The target sensor is a wrist-worn wireless heart rate and arterial oxygen saturation (SpO2) monitor with the goal of providing efficient wireless functionality and long battery lifetime using a commercial Sub-GHz low-power radio transceiver. A detailed analysis of current consumption for various wireless protocols is also presented and analyzed. A novel 915 MHz antenna design of compact size is reported that has good resilience to detuning by the human body. The antenna also incorporates a matching network to meet the challenging bandwidth requirements and is fabricated using standard, low-cost FR-4 material. Full-Wave EM simulations are presented for the antenna placed in both free-space and on-body cases. A prototype antenna is demonstrated and has dimensions of 44 mm × 28 mm × 1.6 mm. The measured results at 915 MHz show a 10 dB return loss bandwidth of 55 MHz, a peak realized gain of −2.37 dBi in free-space and −6.1 dBi on-body. The paper concludes by highlighting the potential benefits of 915 MHz operation for future IoT devices. PMID:29271941
Potential of Sub-GHz Wireless for Future IoT Wearables and Design of Compact 915 MHz Antenna.
Di Serio, Adolfo; Buckley, John; Barton, John; Newberry, Robert; Rodencal, Matthew; Dunlop, Gary; O'Flynn, Brendan
2017-12-22
Internet of Things (IoT) technology is rapidly emerging in medical applications as it offers the possibility of lower-cost personalized healthcare monitoring. At the present time, the 2.45 GHz band is in widespread use for these applications but in this paper, the authors investigate the potential of the 915 MHz ISM band in implementing future, wearable IoT devices. The target sensor is a wrist-worn wireless heart rate and arterial oxygen saturation (SpO2) monitor with the goal of providing efficient wireless functionality and long battery lifetime using a commercial Sub-GHz low-power radio transceiver. A detailed analysis of current consumption for various wireless protocols is also presented and analyzed. A novel 915 MHz antenna design of compact size is reported that has good resilience to detuning by the human body. The antenna also incorporates a matching network to meet the challenging bandwidth requirements and is fabricated using standard, low-cost FR-4 material. Full-Wave EM simulations are presented for the antenna placed in both free-space and on-body cases. A prototype antenna is demonstrated and has dimensions of 44 mm × 28 mm × 1.6 mm. The measured results at 915 MHz show a 10 dB return loss bandwidth of 55 MHz, a peak realized gain of - 2.37 dBi in free-space and - 6.1 dBi on-body. The paper concludes by highlighting the potential benefits of 915 MHz operation for future IoT devices.
Multi-ray medical ultrasound simulation without explicit speckle modelling.
Tuzer, Mert; Yazıcı, Abdulkadir; Türkay, Rüştü; Boyman, Michael; Acar, Burak
2018-05-04
To develop a medical ultrasound (US) simulation method using T1-weighted magnetic resonance images (MRI) as the input that offers a compromise between low-cost ray-based and high-cost realistic wave-based simulations. The proposed method uses a novel multi-ray image formation approach with a virtual phased array transducer probe. A domain model is built from input MR images. Multiple virtual acoustic rays are emerged from each element of the linear transducer array. Reflected and transmitted acoustic energy at discrete points along each ray is computed independently. Simulated US images are computed by fusion of the reflected energy along multiple rays from multiple transducers, while phase delays due to differences in distances to transducers are taken into account. A preliminary implementation using GPUs is presented. Preliminary results show that the multi-ray approach is capable of generating view point-dependent realistic US images with an inherent Rician distributed speckle pattern automatically. The proposed simulator can reproduce the shadowing artefacts and demonstrates frequency dependence apt for practical training purposes. We also have presented preliminary results towards the utilization of the method for real-time simulations. The proposed method offers a low-cost near-real-time wave-like simulation of realistic US images from input MR data. It can further be improved to cover the pathological findings using an improved domain model, without any algorithmic updates. Such a domain model would require lesion segmentation or manual embedding of virtual pathologies for training purposes.
A Cost Analysis of a Pancreatic Cancer Screening Protocol in High-Risk Populations
Bruenderman, Elizabeth; Martin, Robert CG
2016-01-01
Background Pancreatic cancer is the 4th leading cause of cancer death in the U.S. A screening protocol is needed to catch early stage, resectable disease. This study suggests a protocol for high-risk individuals and assesses the cost in the context of the Affordable Care Act. Methods Medicare and national average pricing were used for cost analysis of a protocol using MRI/MRCP biannually in high-risk groups. Results: ‘ Costs per year of life added’ based on Medicare and national average costs, respectively, are: $638.62 and $2542.37 for Peutz-Jehgers Syndrome, $945.33 and $3763.44 for Hereditary Pancreatitis, $1141.77 and $4545.45 for Familial Pancreatic Cancer and p16-Leiden mutations, and $356.42 and $1418.92 for new-onset diabetes over age 50 with weight loss or smoking. Conclusion A screening program using MRI/MRCP is affordable in high-risk populations. The U.S. Preventive Services Task Force must reevaluate its pancreatic cancer screening guidelines to make screening more cost-effective for the individual. PMID:26003200
Lee, Jumin; Cheng, Xi; Swails, Jason M.; ...
2015-11-12
Here we report that proper treatment of nonbonded interactions is essential for the accuracy of molecular dynamics (MD) simulations, especially in studies of lipid bilayers. The use of the CHARMM36 force field (C36 FF) in different MD simulation programs can result in disagreements with published simulations performed with CHARMM due to differences in the protocols used to treat the long-range and 1-4 nonbonded interactions. In this study, we systematically test the use of the C36 lipid FF in NAMD, GROMACS, AMBER, OpenMM, and CHARMM/OpenMM. A wide range of Lennard-Jones (LJ) cutoff schemes and integrator algorithms were tested to find themore » optimal simulation protocol to best match bilayer properties of six lipids with varying acyl chain saturation and head groups. MD simulations of a 1,2-dipalmitoyl-sn-phosphatidylcholine (DPPC) bilayer were used to obtain the optimal protocol for each program. MD simulations with all programs were found to reasonably match the DPPC bilayer properties (surface area per lipid, chain order parameters, and area compressibility modulus) obtained using the standard protocol used in CHARMM as well as from experiments. The optimal simulation protocol was then applied to the other five lipid simulations and resulted in excellent agreement between results from most simulation programs as well as with experimental data. AMBER compared least favorably with the expected membrane properties, which appears to be due to its use of the hard-truncation in the LJ potential versus a force-based switching function used to smooth the LJ potential as it approaches the cutoff distance. The optimal simulation protocol for each program has been implemented in CHARMM-GUI. This protocol is expected to be applicable to the remainder of the additive C36 FF including the proteins, nucleic acids, carbohydrates, and small molecules.« less
Lee, Jumin; Cheng, Xi; Swails, Jason M; Yeom, Min Sun; Eastman, Peter K; Lemkul, Justin A; Wei, Shuai; Buckner, Joshua; Jeong, Jong Cheol; Qi, Yifei; Jo, Sunhwan; Pande, Vijay S; Case, David A; Brooks, Charles L; MacKerell, Alexander D; Klauda, Jeffery B; Im, Wonpil
2016-01-12
Proper treatment of nonbonded interactions is essential for the accuracy of molecular dynamics (MD) simulations, especially in studies of lipid bilayers. The use of the CHARMM36 force field (C36 FF) in different MD simulation programs can result in disagreements with published simulations performed with CHARMM due to differences in the protocols used to treat the long-range and 1-4 nonbonded interactions. In this study, we systematically test the use of the C36 lipid FF in NAMD, GROMACS, AMBER, OpenMM, and CHARMM/OpenMM. A wide range of Lennard-Jones (LJ) cutoff schemes and integrator algorithms were tested to find the optimal simulation protocol to best match bilayer properties of six lipids with varying acyl chain saturation and head groups. MD simulations of a 1,2-dipalmitoyl-sn-phosphatidylcholine (DPPC) bilayer were used to obtain the optimal protocol for each program. MD simulations with all programs were found to reasonably match the DPPC bilayer properties (surface area per lipid, chain order parameters, and area compressibility modulus) obtained using the standard protocol used in CHARMM as well as from experiments. The optimal simulation protocol was then applied to the other five lipid simulations and resulted in excellent agreement between results from most simulation programs as well as with experimental data. AMBER compared least favorably with the expected membrane properties, which appears to be due to its use of the hard-truncation in the LJ potential versus a force-based switching function used to smooth the LJ potential as it approaches the cutoff distance. The optimal simulation protocol for each program has been implemented in CHARMM-GUI. This protocol is expected to be applicable to the remainder of the additive C36 FF including the proteins, nucleic acids, carbohydrates, and small molecules.
Toward a Mobility-Driven Architecture for Multimodal Underwater Networking
2017-02-01
applications. By equipping AUVs with short-range, high -bandwidth underwater wireless communications , which feature lower energy-per-bit cost than acoustic...protocols. They suffer from significant transmission path losses at high frequencies , long propagation delays, low and distance-dependent bandwidth, time...of data preprocessing, data compression, and either tethering to a surface buoy able to use radio frequency (RF) communications or using undersea
A Graphical User Interface for the Low Cost Combat Direction System
1991-09-16
the same tasks. These shipboard tasks, which include contact management , moving geometry calculations, intelligence compila- tion, area plotting and...Display Defaults Analysis This category covers a wide range of required data input and system configuration issues. To keep the screen display manageable ...parts or dialog boxes. The implementation of an Ada application using STARS is quite straightforward, although knowlede of X Protocol primitives is
John A. Scrivani; Randolph H. Wynne; Christine E. Blinn; Rebecca F. Musy
2001-01-01
Two methods of training data collection for automated image classification were tested in Virginia as part of a larger effort to develop an objective, repeatable, and low-cost method to provide forest area classification from satellite imagery. The derived forest area estimates were compared to estimates derived from a traditional photo-interpreted, double sample. One...
Hurley, Deirdre A; Hall, Amanda M; Currie-Murphy, Laura; Pincus, Tamar; Kamper, Steve; Maher, Chris; McDonough, Suzanne M; Lonsdale, Chris; Walsh, Nicola E; Guerin, Suzanne; Segurado, Ricardo; Matthews, James
2016-01-01
Introduction International clinical guidelines consistently endorse the promotion of self-management (SM), including physical activity for patients with chronic low back pain (CLBP) and osteoarthritis (OA). Patients frequently receive individual treatment and advice to self-manage from physiotherapists in primary care, but the successful implementation of a clinical and cost-effective group SM programme is a key priority for health service managers in Ireland to maximise long-term outcomes and efficient use of limited and costly resources. Methods/analysis This protocol describes an assessor-blinded cluster randomised controlled feasibility trial of a group-based education and exercise intervention underpinned by self-determination theory designed to support an increase in SM behaviour in patients with CLBP and OA in primary care physiotherapy. The primary care clinic will be the unit of randomisation (cluster), with each clinic randomised to 1 of 2 groups providing the Self-management of Osteoarthritis and Low back pain through Activity and Skills (SOLAS) intervention or usual individual physiotherapy. Patients are followed up at 6 weeks, 2 and 6 months. The primary outcomes are the (1) acceptability and demand of the intervention to patients and physiotherapists, (2) feasibility and optimal study design/procedures and sample size for a definitive trial. Secondary outcomes include exploratory analyses of: point estimates, 95% CIs, change scores and effect sizes in physical function, pain and disability outcomes; process of change in target SM behaviours and selected mediators; and the cost of the intervention to inform a definitive trial. Ethics/dissemination This feasibility trial protocol was approved by the UCD Human Research Ethics—Sciences Committee (LS-13-54 Currie-Hurley) and research access has been granted by the Health Services Executive Primary Care Research Committee in January 2014. The study findings will be disseminated to the research, clinical and health service communities through publication in peer-reviewed journals, presentation at national and international academic and clinical conferences. Trial registration number ISRCTN 49875385; Pre-results. PMID:26801470
Paper-based chromatic toxicity bioassay by analysis of bacterial ferricyanide reduction.
Pujol-Vila, F; Vigués, N; Guerrero-Navarro, A; Jiménez, S; Gómez, D; Fernández, M; Bori, J; Vallès, B; Riva, M C; Muñoz-Berbel, X; Mas, J
2016-03-03
Water quality assessment requires a continuous and strict analysis of samples to guarantee compliance with established standards. Nowadays, the increasing number of pollutants and their synergistic effects lead to the development general toxicity bioassays capable to analyse water pollution as a whole. Current general toxicity methods, e.g. Microtox(®), rely on long operation protocols, the use of complex and expensive instrumentation and sample pre-treatment, which should be transported to the laboratory for analysis. These requirements delay sample analysis and hence, the response to avoid an environmental catastrophe. In an attempt to solve it, a fast (15 min) and low-cost toxicity bioassay based on the chromatic changes associated to bacterial ferricyanide reduction is here presented. E. coli cells (used as model bacteria) were stably trapped on low-cost paper matrices (cellulose-based paper discs, PDs) and remained viable for long times (1 month at -20 °C). Apart from bacterial carrier, paper matrices also acted as a fluidic element, allowing fluid management without the need of external pumps. Bioassay evaluation was performed using copper as model toxic agent. Chromatic changes associated to bacterial ferricyanide reduction were determined by three different transduction methods, i.e. (i) optical reflectometry (as reference method), (ii) image analysis and (iii) visual inspection. In all cases, bioassay results (in terms of half maximal effective concentrations, EC50) were in agreement with already reported data, confirming the good performance of the bioassay. The validation of the bioassay was performed by analysis of real samples from natural sources, which were analysed and compared with a reference method (i.e. Microtox). Obtained results showed agreement for about 70% of toxic samples and 80% of non-toxic samples, which may validate the use of this simple and quick protocol in the determination of general toxicity. The minimum instrumentation requirements and the simplicity of the bioassay open the possibility of in-situ water toxicity assessment with a fast and low-cost protocol. Copyright © 2016 Elsevier B.V. All rights reserved.
Hurley, Deirdre A; Hall, Amanda M; Currie-Murphy, Laura; Pincus, Tamar; Kamper, Steve; Maher, Chris; McDonough, Suzanne M; Lonsdale, Chris; Walsh, Nicola E; Guerin, Suzanne; Segurado, Ricardo; Matthews, James
2016-01-21
International clinical guidelines consistently endorse the promotion of self-management (SM), including physical activity for patients with chronic low back pain (CLBP) and osteoarthritis (OA). Patients frequently receive individual treatment and advice to self-manage from physiotherapists in primary care, but the successful implementation of a clinical and cost-effective group SM programme is a key priority for health service managers in Ireland to maximise long-term outcomes and efficient use of limited and costly resources. This protocol describes an assessor-blinded cluster randomised controlled feasibility trial of a group-based education and exercise intervention underpinned by self-determination theory designed to support an increase in SM behaviour in patients with CLBP and OA in primary care physiotherapy. The primary care clinic will be the unit of randomisation (cluster), with each clinic randomised to 1 of 2 groups providing the Self-management of Osteoarthritis and Low back pain through Activity and Skills (SOLAS) intervention or usual individual physiotherapy. Patients are followed up at 6 weeks, 2 and 6 months. The primary outcomes are the (1) acceptability and demand of the intervention to patients and physiotherapists, (2) feasibility and optimal study design/procedures and sample size for a definitive trial. Secondary outcomes include exploratory analyses of: point estimates, 95% CIs, change scores and effect sizes in physical function, pain and disability outcomes; process of change in target SM behaviours and selected mediators; and the cost of the intervention to inform a definitive trial. This feasibility trial protocol was approved by the UCD Human Research Ethics-Sciences Committee (LS-13-54 Currie-Hurley) and research access has been granted by the Health Services Executive Primary Care Research Committee in January 2014. The study findings will be disseminated to the research, clinical and health service communities through publication in peer-reviewed journals, presentation at national and international academic and clinical conferences. ISRCTN 49875385; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Lobban, Fiona; Robinson, Heather; Appelbe, Duncan; Barraclough, Johanna; Bedson, Emma; Collinge, Lizzi; Dodd, Susanna; Flowers, Sue; Honary, Mahsa; Johnson, Sonia; Mateus, Ceu; Mezes, Barbara; Minns, Valerie; Murray, Elizabeth; Walker, Andrew; Williamson, Paula; Wintermeyer, Catherine; Jones, Steven
2017-07-18
Despite clinical guidelines recommendations, many relatives of people with psychosis or bipolar disorder do not currently receive the support they need. Online information and support may offer a solution. This single-blind, parallel, online randomised controlled trial will determine clinical and cost-effectiveness of the Relatives Education And Coping Toolkit (REACT) (including an online resource directory (RD)), compared with RD only, for relatives of people with psychosis or bipolar disorder. Both groups continue to receive treatment as usual. Independent, web-based variable, block, individual randomisation will be used across 666 relatives. Primary outcome is distress at 24 weeks (measured by General Health Questionnaire; GHQ-28) compared between groups using analysis of covariance, adjusting for baseline score. Secondary clinical outcomes are carer well-being and support. Cost-effectiveness analysis will determine cost of a significant unit change (three-point reduction) in the GHQ-28. Costs include offering and supporting the intervention in the REACT arm, relevant healthcare care costs including health professional contacts, medications prescribed and time off (or ability to) work for the relative. Cost utility analysis will be calculated as the marginal cost of changes in quality-adjusted life years, based on EuroQol. We will explore relatives' beliefs, perceived coping and amount of REACT toolkit use as possible outcome mediators. We have embedded two methodological substudies in the protocol to determine the relative effectiveness of a low-value (£10) versus higher value (£20) incentive, and an unconditional versus conditional incentive, on improving follow-up rates. The trial has ethical approval from Lancaster National Research Ethics Service (NRES)Committee (15/NW/0732) and is overseen by an independent Data Monitoring and Ethics Committee and Trial Steering Committee. Protocol version 1.5 was approved on 9 January 2017. All updates to protocols are uploaded to the National Institute for Health Research (NIHR) Journals Library. A full statistical analysis plan is available at https://figshare.com/account/home#/projects/19975. Publications will be in peer-reviewed journals (open access wherever possible). Requests for access to the data at the end of the study will be reviewed and granted where appropriate by the Trial Management Group. ISRCTN72019945, pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Numerical Propulsion System Simulation: An Overview
NASA Technical Reports Server (NTRS)
Lytle, John K.
2000-01-01
The cost of implementing new technology in aerospace propulsion systems is becoming prohibitively expensive and time consuming. One of the main contributors to the high cost and lengthy time is the need to perform many large-scale hardware tests and the inability to integrate all appropriate subsystems early in the design process. The NASA Glenn Research Center is developing the technologies required to enable simulations of full aerospace propulsion systems in sufficient detail to resolve critical design issues early in the design process before hardware is built. This concept, called the Numerical Propulsion System Simulation (NPSS), is focused on the integration of multiple disciplines such as aerodynamics, structures and heat transfer with computing and communication technologies to capture complex physical processes in a timely and cost-effective manner. The vision for NPSS, as illustrated, is to be a "numerical test cell" that enables full engine simulation overnight on cost-effective computing platforms. There are several key elements within NPSS that are required to achieve this capability: 1) clear data interfaces through the development and/or use of data exchange standards, 2) modular and flexible program construction through the use of object-oriented programming, 3) integrated multiple fidelity analysis (zooming) techniques that capture the appropriate physics at the appropriate fidelity for the engine systems, 4) multidisciplinary coupling techniques and finally 5) high performance parallel and distributed computing. The current state of development in these five area focuses on air breathing gas turbine engines and is reported in this paper. However, many of the technologies are generic and can be readily applied to rocket based systems and combined cycles currently being considered for low-cost access-to-space applications. Recent accomplishments include: (1) the development of an industry-standard engine cycle analysis program and plug 'n play architecture, called NPSS Version 1, (2) A full engine simulation that combines a 3D low-pressure subsystem with a 0D high pressure core simulation. This demonstrates the ability to integrate analyses at different levels of detail and to aerodynamically couple components, the fan/booster and low-pressure turbine, through a 3D computational fluid dynamics simulation. (3) Simulation of all of the turbomachinery in a modern turbofan engine on parallel computing platform for rapid and cost-effective execution. This capability can also be used to generate full compressor map, requiring both design and off-design simulation. (4) Three levels of coupling characterize the multidisciplinary analysis under NPSS: loosely coupled, process coupled and tightly coupled. The loosely coupled and process coupled approaches require a common geometry definition to link CAD to analysis tools. The tightly coupled approach is currently validating the use of arbitrary Lagrangian/Eulerian formulation for rotating turbomachinery. The validation includes both centrifugal and axial compression systems. The results of the validation will be reported in the paper. (5) The demonstration of significant computing cost/performance reduction for turbine engine applications using PC clusters. The NPSS Project is supported under the NASA High Performance Computing and Communications Program.
Study of CdTe/CdS solar cell at low power density for low-illumination applications
NASA Astrophysics Data System (ADS)
Devi, Nisha; Aziz, Anver; Datta, Shouvik
2016-05-01
In this paper, we numerically investigate CdTe/CdS PV cell properties using a simulation program Solar Cell Capacitance Simulator in 1D (SCAPS-1D). A simple structure of CdTe PV cell has been optimized to study the effect of temperature, absorber thickness and work function at very low incident power. Objective of this research paper is to build an efficient and cost effective solar cell for portable electronic devices such as portable computers and cell phones that work at low incident power because most of such devices work at diffused and reflected sunlight. In this report, we simulated a simple CdTe PV cell at very low incident power, which gives good efficiency.
Implementation of quantum key distribution network simulation module in the network simulator NS-3
NASA Astrophysics Data System (ADS)
Mehic, Miralem; Maurhart, Oliver; Rass, Stefan; Voznak, Miroslav
2017-10-01
As the research in quantum key distribution (QKD) technology grows larger and becomes more complex, the need for highly accurate and scalable simulation technologies becomes important to assess the practical feasibility and foresee difficulties in the practical implementation of theoretical achievements. Due to the specificity of the QKD link which requires optical and Internet connection between the network nodes, to deploy a complete testbed containing multiple network hosts and links to validate and verify a certain network algorithm or protocol would be very costly. Network simulators in these circumstances save vast amounts of money and time in accomplishing such a task. The simulation environment offers the creation of complex network topologies, a high degree of control and repeatable experiments, which in turn allows researchers to conduct experiments and confirm their results. In this paper, we described the design of the QKD network simulation module which was developed in the network simulator of version 3 (NS-3). The module supports simulation of the QKD network in an overlay mode or in a single TCP/IP mode. Therefore, it can be used to simulate other network technologies regardless of QKD.
Shi, Xiaobo; Li, Wei; Song, Jeungeun; Hossain, M Shamim; Mizanur Rahman, Sk Md; Alelaiwi, Abdulhameed
2016-10-01
With the development of IoT (Internet of Thing), big data analysis and cloud computing, traditional medical information system integrates with these new technologies. The establishment of cloud-based smart healthcare application gets more and more attention. In this paper, semi-physical simulation technology is applied to cloud-based smart healthcare system. The Body sensor network (BSN) of system transmit has two ways of data collection and transmission. The one is using practical BSN to collect data and transmitting it to the data center. The other is transmitting real medical data to practical data center by simulating BSN. In order to transmit real medical data to practical data center by simulating BSN under semi-physical simulation environment, this paper designs an OPNET packet structure, defines a gateway node model between simulating BSN and practical data center and builds a custom protocol stack. Moreover, this paper conducts a large amount of simulation on the real data transmission through simulation network connecting with practical network. The simulation result can provides a reference for parameter settings of fully practical network and reduces the cost of devices and personnel involved.
Demonstration of the Low-Cost Virtual Collaborative Environment (VCE)
NASA Technical Reports Server (NTRS)
Bowers, David; Montes, Leticia; Ramos, Angel; Joyce, Brendan; Lumia, Ron
1997-01-01
This paper demonstrates the feasibility of a low-cost approach of remotely controlling equipment. Our demonstration system consists of a PC, the PUMA 560 robot with Barrett hand, and commercially available controller and teleconferencing software. The system provides a graphical user interface which allows a user to program equipment tasks and preview motions i.e., simulate the results. Once satisfied that the actions are both safe and accomplish the task, the remote user sends the data over the Internet to the local site for execution on the real equipment. A video link provides visual feedback to the remote sight. This technology lends itself readily to NASA's upcoming Mars expeditions by providing remote simulation and control of equipment.
Cost-effectiveness of diabetes case management for low-income populations.
Gilmer, Todd P; Roze, Stéphane; Valentine, William J; Emy-Albrecht, Katrina; Ray, Joshua A; Cobden, David; Nicklasson, Lars; Philis-Tsimikas, Athena; Palmer, Andrew J
2007-10-01
To evaluate the cost-effectiveness of Project Dulce, a culturally specific diabetes case management and self-management training program, in four cohorts defined by insurance status. Clinical and cost data on 3,893 persons with diabetes participating in Project Dulce were used as inputs into a diabetes simulation model. The Center for Outcomes Research Diabetes Model, a published, peer-reviewed and validated simulation model of diabetes, was used to evaluate life expectancy, quality-adjusted life expectancy (QALY), cumulative incidence of complications and direct medical costs over patient lifetimes (40-year time horizon) from a third-party payer perspective. Cohort characteristics, treatment effects, and case management costs were derived using a difference in difference design comparing data from the Project Dulce program to a cohort of historical controls. Long-term costs were derived from published U.S. sources. Costs and clinical benefits were discounted at 3.0 percent per annum. Sensitivity analyses were performed. Incremental cost-effectiveness ratios of $10,141, $24,584, $44,941, and $69,587 per QALY gained were estimated for Project Dulce participants versus control in the uninsured, County Medical Services, Medi-Cal, and commercial insurance cohorts, respectively. The Project Dulce diabetes case management program was associated with cost-effective improvements in quality-adjusted life expectancy and decreased incidence of diabetes-related complications over patient lifetimes. Diabetes case management may be particularly cost effective for low-income populations.
CT scans for pulmonary surveillance may be overused in lower-grade sarcoma.
Miller, Benjamin J; Carmody Soni, Emily E; Reith, John D; Gibbs, C Parker; Scarborough, Mark T
2012-01-01
Chest CT scans are often used to monitor patients after excision of a sarcoma. Although sensitive, CT scans are more expensive than chest radiographs and are associated with possible health risks from a higher radiation dose. We hypothesized that a program based upon limited CT scans in lower-grade sarcoma could be efficacious and less expensive. We retrospectively assigned patients to a high-risk or low-risk hypothetical protocol. Eighty-three low- or intermediate-grade soft tissue sarcomas met our inclusion criteria. Eight patients had pulmonary metastasis. A protocol based on selective CT scans for high-risk patients would have identified seven out of eight lesions. The incremental cost-effectiveness ratio for routine CT scans was $731,400. A program based upon selective CT scans for higher-risk patients is accurate, spares unnecessary radiation to many patients, and is less expensive.
A community-based approach to trials of aerobic exercise in aging and Alzheimer’s disease
Vidoni, Eric D.; Van Sciver, Angela; Johnson, David K.; He, Jinghua; Honea, Robyn; Haines, Brian; Goodwin, Jami; Laubinger, M. Pat; Anderson, Heather S.; Kluding, Patricia M.; Donnelly, Joseph E.; Billinger, Sandra A.; Burns, Jeffrey M.
2012-01-01
The benefits of exercise for aging have received considerable attention in both the popular and academic press. The putative benefits of exercise for maximizing cognitive function and supporting brain health have great potential for combating Alzheimer’s disease (AD). Aerobic exercise offers a low-cost, low-risk intervention that is widely available and may have disease modifying effects. Demonstrating aerobic exercise alters the AD process would have enormous public health implications. The purpose of this paper is to a report the protocol of a current, community-based pilot study of aerobic exercise for AD to guide future investigation. This manuscript provides 1) an overview of possible benefits of exercise in those with dementia, 2) a rationale and recommendations for implementation of a community-based approach, 3) recommendation for implementation of similar study protocols, 4) unique challenges in conducting an exercise trial in AD. PMID:22903151
Saper, Robert B; Sherman, Karen J; Delitto, Anthony; Herman, Patricia M; Stevans, Joel; Paris, Ruth; Keosaian, Julia E; Cerrada, Christian J; Lemaster, Chelsey M; Faulkner, Carol; Breuer, Maya; Weinberg, Janice
2014-02-26
Chronic low back pain causes substantial morbidity and cost to society while disproportionately impacting low-income and minority adults. Several randomized controlled trials show yoga is an effective treatment. However, the comparative effectiveness of yoga and physical therapy, a common mainstream treatment for chronic low back pain, is unknown. This is a randomized controlled trial for 320 predominantly low-income minority adults with chronic low back pain, comparing yoga, physical therapy, and education. Inclusion criteria are adults 18-64 years old with non-specific low back pain lasting ≥ 12 weeks and a self-reported average pain intensity of ≥ 4 on a 0-10 scale. Recruitment takes place at Boston Medical Center, an urban academic safety-net hospital and seven federally qualified community health centers located in diverse neighborhoods. The 52-week study has an initial 12-week Treatment Phase where participants are randomized in a 2:2:1 ratio into i) a standardized weekly hatha yoga class supplemented by home practice; ii) a standardized evidence-based exercise therapy protocol adapted from the Treatment Based Classification method, individually delivered by a physical therapist and supplemented by home practice; and iii) education delivered through a self-care book. Co-primary outcome measures are 12-week pain intensity measured on an 11-point numerical rating scale and back-specific function measured using the modified Roland Morris Disability Questionnaire. In the subsequent 40-week Maintenance Phase, yoga participants are re-randomized in a 1:1 ratio to either structured maintenance yoga classes or home practice only. Physical therapy participants are similarly re-randomized to either five booster sessions or home practice only. Education participants continue to follow recommendations of educational materials. We will also assess cost effectiveness from the perspectives of the individual, insurers, and society using claims databases, electronic medical records, self-report cost data, and study records. Qualitative data from interviews will add subjective detail to complement quantitative data. This trial is registered in ClinicalTrials.gov, with the ID number: NCT01343927.
2014-01-01
Background Chronic low back pain causes substantial morbidity and cost to society while disproportionately impacting low-income and minority adults. Several randomized controlled trials show yoga is an effective treatment. However, the comparative effectiveness of yoga and physical therapy, a common mainstream treatment for chronic low back pain, is unknown. Methods/Design This is a randomized controlled trial for 320 predominantly low-income minority adults with chronic low back pain, comparing yoga, physical therapy, and education. Inclusion criteria are adults 18–64 years old with non-specific low back pain lasting ≥12 weeks and a self-reported average pain intensity of ≥4 on a 0–10 scale. Recruitment takes place at Boston Medical Center, an urban academic safety-net hospital and seven federally qualified community health centers located in diverse neighborhoods. The 52-week study has an initial 12-week Treatment Phase where participants are randomized in a 2:2:1 ratio into i) a standardized weekly hatha yoga class supplemented by home practice; ii) a standardized evidence-based exercise therapy protocol adapted from the Treatment Based Classification method, individually delivered by a physical therapist and supplemented by home practice; and iii) education delivered through a self-care book. Co-primary outcome measures are 12-week pain intensity measured on an 11-point numerical rating scale and back-specific function measured using the modified Roland Morris Disability Questionnaire. In the subsequent 40-week Maintenance Phase, yoga participants are re-randomized in a 1:1 ratio to either structured maintenance yoga classes or home practice only. Physical therapy participants are similarly re-randomized to either five booster sessions or home practice only. Education participants continue to follow recommendations of educational materials. We will also assess cost effectiveness from the perspectives of the individual, insurers, and society using claims databases, electronic medical records, self-report cost data, and study records. Qualitative data from interviews will add subjective detail to complement quantitative data. Trial registration This trial is registered in ClinicalTrials.gov, with the ID number: NCT01343927. PMID:24568299
A Bone Marrow Aspirate and Trephine Simulator.
Yap, Eng Soo; Koh, Pei Lin; Ng, Chin Hin; de Mel, Sanjay; Chee, Yen Lin
2015-08-01
Bone marrow aspirate and trephine (BMAT) biopsy is a commonly performed procedure in hematology-oncology practice. Although complications are uncommon, they can cause significant morbidity and mortality. Simulation models are an excellent tool to teach novice doctors basic procedural skills before performing the actual procedure on patients to improve patient safety and well-being. There are no commercial BMAT simulators, and this technical report describes the rationale, technical specifications, and construction of a low-cost, easily constructed, reusable BMAT simulator that reproduced the tactile properties of tissue layers for use as a teaching tool in our resident BMAT simulation course. Preliminary data of learner responses to the simulator were also collected. From April 2013 to November 2013, 32 internal medicine residents underwent the BMAT simulation course. Eighteen (56%) completed the online survey, 11 residents with previous experience doing BMAT and 7 without experience. Despite the difference in operative experience, both experienced and novice residents all agreed or strongly agreed that the model aided their understanding of the BMAT procedure. All agreed or strongly agreed that this enhanced their knowledge of anatomy and 16 residents (89%) agreed or strongly agreed that this model was a realistic simulator. We present a novel, low-cost, easily constructed, realistic BMAT simulator for training novice doctors to perform BMAT.
NASA Technical Reports Server (NTRS)
Lansing, F. L.; Chai, V. W.; Lascu, D.; Urbenajo, R.; Wong, P.
1978-01-01
The engineering manual provides a complete companion documentation about the structure of the main program and subroutines, the preparation of input data, the interpretation of output results, access and use of the program, and the detailed description of all the analytic, logical expressions and flow charts used in computations and program structure. A numerical example is provided and solved completely to show the sequence of computations followed. The program is carefully structured to reduce both user's time and costs without sacrificing accuracy. The user would expect a cost of CPU time of approximately $5.00 per building zone excluding printing costs. The accuracy, on the other hand, measured by deviation of simulated consumption from watt-hour meter readings, was found by many simulation tests not to exceed + or - 10 percent margin.
Spanou, Clio; Simpson, Sharon A; Hood, Kerry; Edwards, Adrian; Cohen, David; Rollnick, Stephen; Carter, Ben; McCambridge, Jim; Moore, Laurence; Randell, Elizabeth; Pickles, Timothy; Smith, Christine; Lane, Claire; Wood, Fiona; Thornton, Hazel; Butler, Chris C
2010-09-21
Smoking, excessive alcohol consumption, lack of exercise and an unhealthy diet are the key modifiable factors contributing to premature morbidity and mortality in the developed world. Brief interventions in health care consultations can be effective in changing single health behaviours. General Practice holds considerable potential for primary prevention through modifying patients' multiple risk behaviours, but feasible, acceptable and effective interventions are poorly developed, and uptake by practitioners is low. Through a process of theoretical development, modeling and exploratory trials, we have developed an intervention called Behaviour Change Counselling (BCC) derived from Motivational Interviewing (MI). This paper describes the protocol for an evaluation of a training intervention (the Talking Lifestyles Programme) which will enable practitioners to routinely use BCC during consultations for the above four risk behaviours. This cluster randomised controlled efficacy trial (RCT) will evaluate the outcomes and costs of this training intervention for General Practitioners (GPs) and nurses. Training methods will include: a practice-based seminar, online self-directed learning, and reflecting on video recorded and simulated consultations. The intervention will be evaluated in 29 practices in Wales, UK; two clinicians will take part (one GP and one nurse) from each practice. In intervention practices both clinicians will receive training. The aim is to recruit 2000 patients into the study with an expected 30% drop out. The primary outcome will be the proportion of patients making changes in one or more of the four behaviours at three months. Results will be compared for patients seeing clinicians trained in BCC with patients seeing non-BCC trained clinicians. Economic and process evaluations will also be conducted. Opportunistic engagement by health professionals potentially represents a cost effective medical intervention. This study integrates an existing, innovative intervention method with an innovative training model to enable clinicians to routinely use BCC, providing them with new tools to encourage and support people to make healthier choices. This trial will evaluate effectiveness in primary care and determine costs of the intervention.
2010-01-01
Background Smoking, excessive alcohol consumption, lack of exercise and an unhealthy diet are the key modifiable factors contributing to premature morbidity and mortality in the developed world. Brief interventions in health care consultations can be effective in changing single health behaviours. General Practice holds considerable potential for primary prevention through modifying patients' multiple risk behaviours, but feasible, acceptable and effective interventions are poorly developed, and uptake by practitioners is low. Through a process of theoretical development, modeling and exploratory trials, we have developed an intervention called Behaviour Change Counselling (BCC) derived from Motivational Interviewing (MI). This paper describes the protocol for an evaluation of a training intervention (the Talking Lifestyles Programme) which will enable practitioners to routinely use BCC during consultations for the above four risk behaviours. Methods/Design This cluster randomised controlled efficacy trial (RCT) will evaluate the outcomes and costs of this training intervention for General Practitioners (GPs) and nurses. Training methods will include: a practice-based seminar, online self-directed learning, and reflecting on video recorded and simulated consultations. The intervention will be evaluated in 29 practices in Wales, UK; two clinicians will take part (one GP and one nurse) from each practice. In intervention practices both clinicians will receive training. The aim is to recruit 2000 patients into the study with an expected 30% drop out. The primary outcome will be the proportion of patients making changes in one or more of the four behaviours at three months. Results will be compared for patients seeing clinicians trained in BCC with patients seeing non-BCC trained clinicians. Economic and process evaluations will also be conducted. Discussion Opportunistic engagement by health professionals potentially represents a cost effective medical intervention. This study integrates an existing, innovative intervention method with an innovative training model to enable clinicians to routinely use BCC, providing them with new tools to encourage and support people to make healthier choices. This trial will evaluate effectiveness in primary care and determine costs of the intervention. Trial Registration ISRCTN22495456 PMID:20858273
A low-power CMOS operational amplifier IC for a heterogeneous paper-based potentiostat
NASA Astrophysics Data System (ADS)
Bezuidenhout, P.; Land, K.; Joubert, T.-H.
2016-02-01
Electrochemical biosensing is used to detect specific analytes in fluids, such as bacterial and chemical contaminants. A common implementation of an electrochemical readout is a potentiostat, which usually includes potentiometric, amperometric, and impedimetric detection. Recently several researchers have developed small, low-cost, single-chip silicon-based potentiostats. With the advances in heterogeneous integration technology, low-power potentiostats can be implemented on paper and similar low cost substrates. This paper deals with the design of a low-power paper-based amperometric front-end for a low-cost and rapid detection environment. In amperometric detection a voltage signal is provided to a sensor system, while a small current value generated by an electrochemical redox reaction in the system is measured. In order to measure low current values, the noise of the circuit must be minimized, which is accomplished with a pre-amplification front-end stage, typically designed around an operational amplifier core. An appropriate circuit design for a low-power and low-cost amperometric front-end is identified, taking the heterogeneous integration of various components into account. The operational amplifier core is on a bare custom CMOS chip, which will be integrated onto the paper substrate alongside commercial off-the-shelf electronic components. A general-purpose low-power two-stage CMOS amplifier circuit is designed and simulated for the ams 350 nm 5 V process. After the layout design and verification, the IC was submitted for a multi-project wafer manufacturing run. The simulated results are a bandwidth of 2.4 MHz, a common-mode rejection ratio of 70.04 dB, and power dissipation of 0.154 mW, which are comparable with the analytical values.
Low-complexity camera digital signal imaging for video document projection system
NASA Astrophysics Data System (ADS)
Hsia, Shih-Chang; Tsai, Po-Shien
2011-04-01
We present high-performance and low-complexity algorithms for real-time camera imaging applications. The main functions of the proposed camera digital signal processing (DSP) involve color interpolation, white balance, adaptive binary processing, auto gain control, and edge and color enhancement for video projection systems. A series of simulations demonstrate that the proposed method can achieve good image quality while keeping computation cost and memory requirements low. On the basis of the proposed algorithms, the cost-effective hardware core is developed using Verilog HDL. The prototype chip has been verified with one low-cost programmable device. The real-time camera system can achieve 1270 × 792 resolution with the combination of extra components and can demonstrate each DSP function.
Revisiting control establishments for emerging energy hubs
NASA Astrophysics Data System (ADS)
Nasirian, Vahidreza
Emerging small-scale energy systems, i.e., microgrids and smartgrids, rely on centralized controllers for voltage regulation, load sharing, and economic dispatch. However, the central controller is a single-point-of-failure in such a design as either the controller or attached communication links failure can render the entire system inoperable. This work seeks for alternative distributed control structures to improve system reliability and help to the scalability of the system. A cooperative distributed controller is proposed that uses a noise-resilient voltage estimator and handles global voltage regulation and load sharing across a DC microgrid. Distributed adaptive droop control is also investigated as an alternative solution. A droop-free distributed control is offered to handle voltage/frequency regulation and load sharing in AC systems. This solution does not require frequency measurement and, thus, features a fast frequency regulation. Distributed economic dispatch is also studied, where a distributed protocol is designed that controls generation units to merge their incremental costs into a consensus and, thus, push the entire system to generate with the minimum cost. Experimental verifications and Hardware-in-the-Loop (HIL) simulations are used to study efficacy of the proposed control protocols.
Breheny, Katie; Adab, Peymane; Passmore, Sandra; Martin, James; Lancashire, Emma; Hemming, Karla; Frew, Emma
2018-01-11
Childhood obesity prevention is a public health priority. Children spend a large proportion of their waking time in school; therefore this is an appropriate setting to implement obesity prevention initiatives. Anecdotal reports suggest that implementing The Daily Mile in schools has had positive effects on childhood obesity, academic attainment and wellbeing. This trial aims to measure the effectiveness of The Daily Mile for improving health and wellbeing. This protocol describes a cluster randomised controlled trial (RCT) in 40 primary schools located in Birmingham, UK. Eligible participants are children in years 3 (aged 7-8) and 5 (aged 9-10). The study compares The Daily Mile (intervention) to usual practice (control) in relation to health and wellbeing. The Daily Mile intervention involves an additional 15 min of running or walking integrated into the school day, throughout a 12 month study period. The primary clinical outcome is body mass index (BMI) z-scores at 12 months following introduction of the intervention. The cost per Quality Adjusted Life Year (QALY) is the primary outcome of the economic evaluation. Secondary outcomes include wellbeing, physical fitness and teacher reported academic attainment. This study is the first RCT investigating the clinical and cost-effectiveness of The Daily Mile. A range of outcomes will be measured to evaluate the broader wellbeing and academic benefits in addition to clinical outcomes typically measured in childhood obesity prevention trials. The intervention is simple and low-cost, therefore if the benefits are demonstrated it has enormous potential to influence future policy. ISRCTN: 12698269 . Date protocol registered 27th October 2016.
Digital Quantum Simulation of Minimal AdS/CFT.
García-Álvarez, L; Egusquiza, I L; Lamata, L; Del Campo, A; Sonner, J; Solano, E
2017-07-28
We propose the digital quantum simulation of a minimal AdS/CFT model in controllable quantum platforms. We consider the Sachdev-Ye-Kitaev model describing interacting Majorana fermions with randomly distributed all-to-all couplings, encoding nonlocal fermionic operators onto qubits to efficiently implement their dynamics via digital techniques. Moreover, we also give a method for probing nonequilibrium dynamics and the scrambling of information. Finally, our approach serves as a protocol for reproducing a simplified low-dimensional model of quantum gravity in advanced quantum platforms as trapped ions and superconducting circuits.
Digital Quantum Simulation of Minimal AdS /CFT
NASA Astrophysics Data System (ADS)
García-Álvarez, L.; Egusquiza, I. L.; Lamata, L.; del Campo, A.; Sonner, J.; Solano, E.
2017-07-01
We propose the digital quantum simulation of a minimal AdS /CFT model in controllable quantum platforms. We consider the Sachdev-Ye-Kitaev model describing interacting Majorana fermions with randomly distributed all-to-all couplings, encoding nonlocal fermionic operators onto qubits to efficiently implement their dynamics via digital techniques. Moreover, we also give a method for probing nonequilibrium dynamics and the scrambling of information. Finally, our approach serves as a protocol for reproducing a simplified low-dimensional model of quantum gravity in advanced quantum platforms as trapped ions and superconducting circuits.
Whole Building Cost and Performance Measurement: Data Collection Protocol Revision 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, Kimberly M.; Spees, Kathleen L.; Kora, Angela R.
2009-03-27
This protocol was written for the Department of Energy’s Federal Energy Management Program (FEMP) to be used by the public as a tool for assessing building cost and performance measurement. The primary audiences are sustainable design professionals, asset owners, building managers, and research professionals within the Federal sector. The protocol was developed based on the need for measured performance and cost data on sustainable design projects. Historically there has not been a significant driver in the public or private sector to quantify whole building performance in comparable terms. The deployment of sustainable design into the building sector has initiated manymore » questions on the performance and operational cost of these buildings.« less
Pediatric laryngeal simulator using 3D printed models: A novel technique.
Kavanagh, Katherine R; Cote, Valerie; Tsui, Yvonne; Kudernatsch, Simon; Peterson, Donald R; Valdez, Tulio A
2017-04-01
Simulation to acquire and test technical skills is an essential component of medical education and residency training in both surgical and nonsurgical specialties. High-quality simulation education relies on the availability, accessibility, and reliability of models. The objective of this work was to describe a practical pediatric laryngeal model for use in otolaryngology residency training. Ideally, this model would be low-cost, have tactile properties resembling human tissue, and be reliably reproducible. Pediatric laryngeal models were developed using two manufacturing methods: direct three-dimensional (3D) printing of anatomical models and casted anatomical models using 3D-printed molds. Polylactic acid, acrylonitrile butadiene styrene, and high-impact polystyrene (HIPS) were used for the directly printed models, whereas a silicone elastomer (SE) was used for the casted models. The models were evaluated for anatomic quality, ease of manipulation, hardness, and cost of production. A tissue likeness scale was created to validate the simulation model. Fleiss' Kappa rating was performed to evaluate interrater agreement, and analysis of variance was performed to evaluate differences among the materials. The SE provided the most anatomically accurate models, with the tactile properties allowing for surgical manipulation of the larynx. Direct 3D printing was more cost-effective than the SE casting method but did not possess the material properties and tissue likeness necessary for surgical simulation. The SE models of the pediatric larynx created from a casting method demonstrated high quality anatomy, tactile properties comparable to human tissue, and easy manipulation with standard surgical instruments. Their use in a reliable, low-cost, accessible, modular simulation system provides a valuable training resource for otolaryngology residents. N/A. Laryngoscope, 127:E132-E137, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Amin Nili, Vahid; Mansouri, Ehsan; Kavehvash, Zahra; Fakharzadeh, Mohammad; Shabany, Mahdi; Khavasi, Amin
2018-01-01
In this paper, a closed-form two-dimensional reconstruction technique for hybrid frequency and mechanical scanning millimeter-wave (MMW) imaging systems is proposed. Although being commercially implemented in many imaging systems as a low-cost real-time solution, the results of frequency scanning systems have been reconstructed numerically or have been reported as the captured raw data with no clear details. Furthermore, this paper proposes a new framework to utilize the captured data of different frequencies for three-dimensional (3D) reconstruction based on novel proposed closed-form relations. The hybrid frequency and mechanical scanning structure, together with the proposed reconstruction method, yields a low-cost MMW imaging system with a satisfying performance. The extracted reconstruction formulations are validated through numerical simulations, which show comparable image quality with conventional MMW imaging systems, i.e., switched-array (SA) and phased-array (PA) structures. Extensive simulations are also performed in the presence of additive noise, demonstrating the acceptable robustness of the system against system noise compared to SA and comparable performance with PA. Finally, 3D reconstruction of the simulated data shows a depth resolution of better than 10 cm with minimum degradation of lateral resolution in the 10 GHz frequency bandwidth.
Promoting adverse drug reaction reporting: comparison of different approaches.
Ribeiro-Vaz, Inês; Santos, Cristina Costa; Cruz-Correia, Ricardo
2016-01-01
To describe different approaches to promote adverse drug reaction reporting among health care professionals, determining their cost-effectiveness. We analyzed and compared several approaches taken by the Northern Pharmacovigilance Centre (Portugal) to promote adverse drug reaction reporting. Approaches were compared regarding the number and relevance of adverse drug reaction reports obtained and costs involved. Costs by report were estimated by adding the initial costs and the running costs of each intervention. These costs were divided by the number of reports obtained with each intervention, to assess its cost-effectiveness. All the approaches seem to have increased the number of adverse drug reaction reports. We noted the biggest increase with protocols (321 reports, costing 1.96 € each), followed by first educational approach (265 reports, 20.31 €/report) and by the hyperlink approach (136 reports, 15.59 €/report). Regarding the severity of adverse drug reactions, protocols were the most efficient approach, costing 2.29 €/report, followed by hyperlinks (30.28 €/report, having no running costs). Concerning unexpected adverse drug reactions, the best result was obtained with protocols (5.12 €/report), followed by first educational approach (38.79 €/report). We recommend implementing protocols in other pharmacovigilance centers. They seem to be the most efficient intervention, allowing receiving adverse drug reactions reports at lower costs. The increase applied not only to the total number of reports, but also to the severity, unexpectedness and high degree of causality attributed to the adverse drug reactions. Still, hyperlinks have the advantage of not involving running costs, showing the second best performance in cost per adverse drug reactions report.
Controlling mechanisms over the internet
NASA Astrophysics Data System (ADS)
Lumia, Ronald
1997-01-01
The internet, widely available throughout the world, can be used to control robots, machine tools, and other mechanisms. This paper will describe a low-cost virtual collaborative environment (VCE) which will connect users with distant equipment. The system is based on PC technology, and incorporates off-line-programming with on-line execution. A remote user programs the systems graphically and simulates the motions and actions of the mechanism until satisfied with the functionality of the program. The program is then transferred from the remote site to the local site where the real equipment exists. At the local site, the simulation is run again to check the program from a safety standpoint. Then, the local user runs the program on the real equipment. During execution, a camera in the real workspace provides an image back to the remote user through a teleconferencing system. The system costs approximately 12,500 dollars and represents a low-cost alternative to the Sandia National Laboratories VCE.
TU-EF-204-07: Add Tube Current Modulation to a Low Dose Simulation Tool for CT Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Y.; Department of Physics, University of Arizona, Tucson, AZ; Wen, G.
2015-06-15
Purpose: We extended the capabilities of a low dose simulation tool to model Tube-Current Modulation (TCM). TCM is widely used in clinical practice to reduce radiation dose in CT scans. We expect the tool to be valuable for various clinical applications (e.g., optimize protocols, compare reconstruction techniques and evaluate TCM methods). Methods: The tube current is input as a function of z location, instead of a fixed value. Starting from the line integrals of a scan, a new Poisson noise realization at a lower dose is generated for each view. To validate the new functionality, we compared simulated scans withmore » real scans in image space. Results: First we assessed noise in the difference between the low-dose simulations and the original high-dose scan. When the simulated tube current is a step function of z location, the noise at each segment matches the noise of 3 separate constant-tube-current-simulations. Secondly, with a phantom that forces TCM, we compared a low-dose simulation with an equivalent real low-dose scan. The mean CT number of the simulated scan and the real low-dose scan were 137.7±0.6 and 137.8±0.5 respectively. Furthermore, with 240 ROIs, the noise of the simulated scan and the real low-dose scan were 24.03±0.45 and 23.99±0.43 respectively, and they were not statistically different (2-sample t-test, p-value=0.28). The facts that the noise reflected the trend of the TCM curve, and that the absolute noise measurements were not statistically different validated the TCM function. Conclusion: We successfully added tube-current modulation functionality in an existing low dose simulation tool. We demonstrated that the noise reflected an input tube-current modulation curve. In addition, we verified that the noise and mean CT number of our simulation agreed with a real low dose scan. The authors are all employees of Philips. Yijun Ding is also supported by NIBIB P41EB002035 and NIBIB R01EB000803.« less
NASA Technical Reports Server (NTRS)
Wu, Gilbert; Santiago, Confesor
2017-01-01
RTCA Special Committee (SC) 228 has initiated a second phase for the development of minimum operational performance standards (MOPS) for UAS detect and avoid (DAA) systems. Technologies to enable UAS with less available Size, Weight, and Power (SWaP) will be considered. RTCA SC-228 has established sub-working groups and one of the sub-working groups is focused on aligning modeling and simulations activities across all participating committee members. This briefing will describe NASAs modeling and simulation plans for the development of performance standards for low cost, size, weight, and power (C-SWaP) surveillance systems that detect and track non-cooperative aircraft. The briefing will also describe the simulation platform NASA intends to use to support end-to-end verification and validation for these DAA systems. Lastly, the briefing will highlight the experiment plan for our first simulation study, and provide a high-level description of our future flight test plans. This briefing does not contain any results or data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bylaska, Eric J., E-mail: Eric.Bylaska@pnnl.gov; Weare, Jonathan Q., E-mail: weare@uchicago.edu; Weare, John H., E-mail: jweare@ucsd.edu
2013-08-21
Parallel in time simulation algorithms are presented and applied to conventional molecular dynamics (MD) and ab initio molecular dynamics (AIMD) models of realistic complexity. Assuming that a forward time integrator, f (e.g., Verlet algorithm), is available to propagate the system from time t{sub i} (trajectory positions and velocities x{sub i} = (r{sub i}, v{sub i})) to time t{sub i+1} (x{sub i+1}) by x{sub i+1} = f{sub i}(x{sub i}), the dynamics problem spanning an interval from t{sub 0}…t{sub M} can be transformed into a root finding problem, F(X) = [x{sub i} − f(x{sub (i−1})]{sub i} {sub =1,M} = 0, for themore » trajectory variables. The root finding problem is solved using a variety of root finding techniques, including quasi-Newton and preconditioned quasi-Newton schemes that are all unconditionally convergent. The algorithms are parallelized by assigning a processor to each time-step entry in the columns of F(X). The relation of this approach to other recently proposed parallel in time methods is discussed, and the effectiveness of various approaches to solving the root finding problem is tested. We demonstrate that more efficient dynamical models based on simplified interactions or coarsening time-steps provide preconditioners for the root finding problem. However, for MD and AIMD simulations, such preconditioners are not required to obtain reasonable convergence and their cost must be considered in the performance of the algorithm. The parallel in time algorithms developed are tested by applying them to MD and AIMD simulations of size and complexity similar to those encountered in present day applications. These include a 1000 Si atom MD simulation using Stillinger-Weber potentials, and a HCl + 4H{sub 2}O AIMD simulation at the MP2 level. The maximum speedup ((serial execution time)/(parallel execution time) ) obtained by parallelizing the Stillinger-Weber MD simulation was nearly 3.0. For the AIMD MP2 simulations, the algorithms achieved speedups of up to 14.3. The parallel in time algorithms can be implemented in a distributed computing environment using very slow transmission control protocol/Internet protocol networks. Scripts written in Python that make calls to a precompiled quantum chemistry package (NWChem) are demonstrated to provide an actual speedup of 8.2 for a 2.5 ps AIMD simulation of HCl + 4H{sub 2}O at the MP2/6-31G* level. Implemented in this way these algorithms can be used for long time high-level AIMD simulations at a modest cost using machines connected by very slow networks such as WiFi, or in different time zones connected by the Internet. The algorithms can also be used with programs that are already parallel. Using these algorithms, we are able to reduce the cost of a MP2/6-311++G(2d,2p) simulation that had reached its maximum possible speedup in the parallelization of the electronic structure calculation from 32 s/time step to 6.9 s/time step.« less
Komaroff, A L; Flatley, M; Browne, C; Sherman, H; Fineberg, S E; Knopp, R H
1976-04-01
Briefly trained physicians assistants using protocols (clinical algorithms) for diabetes, hypertension, and related chronic arteriosclerotic and hypertensive heart disease abstrated information from the medical record and obtained history and physical examination data on every patient-visit to a city hospital chronic disease clinic over a 18-month period. The care rendered by the protocol system was compared with care rendered by a "traditional" system in the same clinic in which physicians delegated few clinical tasks. Increased thoroughness in collecting clinical data in the protocol system led to an increase in the recognition of new pathology. Outcome criteria reflected equivalent quality of care in both groups. Efficiency time-motion studies demonstrated a 20 per cent saving in physician time with the protocol system. Coct estimates, based on the time spent with patients by various providers and on the laboratory-test-ordering patterns, demonstrated equivalent costs of the two systems, given optimal staffing patterns. Laboratory tests were a major element of the cost of patient care,and the clinical yield per unit cost of different tests varied widely.
Experimental measurement-device-independent verification of quantum steering
NASA Astrophysics Data System (ADS)
Kocsis, Sacha; Hall, Michael J. W.; Bennet, Adam J.; Saunders, Dylan J.; Pryde, Geoff J.
2015-01-01
Bell non-locality between distant quantum systems—that is, joint correlations which violate a Bell inequality—can be verified without trusting the measurement devices used, nor those performing the measurements. This leads to unconditionally secure protocols for quantum information tasks such as cryptographic key distribution. However, complete verification of Bell non-locality requires high detection efficiencies, and is not robust to typical transmission losses over long distances. In contrast, quantum or Einstein-Podolsky-Rosen steering, a weaker form of quantum correlation, can be verified for arbitrarily low detection efficiencies and high losses. The cost is that current steering-verification protocols require complete trust in one of the measurement devices and its operator, allowing only one-sided secure key distribution. Here we present measurement-device-independent steering protocols that remove this need for trust, even when Bell non-locality is not present. We experimentally demonstrate this principle for singlet states and states that do not violate a Bell inequality.
Experimental measurement-device-independent verification of quantum steering.
Kocsis, Sacha; Hall, Michael J W; Bennet, Adam J; Saunders, Dylan J; Pryde, Geoff J
2015-01-07
Bell non-locality between distant quantum systems--that is, joint correlations which violate a Bell inequality--can be verified without trusting the measurement devices used, nor those performing the measurements. This leads to unconditionally secure protocols for quantum information tasks such as cryptographic key distribution. However, complete verification of Bell non-locality requires high detection efficiencies, and is not robust to typical transmission losses over long distances. In contrast, quantum or Einstein-Podolsky-Rosen steering, a weaker form of quantum correlation, can be verified for arbitrarily low detection efficiencies and high losses. The cost is that current steering-verification protocols require complete trust in one of the measurement devices and its operator, allowing only one-sided secure key distribution. Here we present measurement-device-independent steering protocols that remove this need for trust, even when Bell non-locality is not present. We experimentally demonstrate this principle for singlet states and states that do not violate a Bell inequality.
Leo Satellite Communication through a LEO Constellation using TCP/IP Over ATM
NASA Technical Reports Server (NTRS)
Foore, Lawrence R.; Konangi, Vijay K.; Wallett, Thomas M.
1999-01-01
The simulated performance characteristics for communication between a terrestrial client and a Low Earth Orbit (LEO) satellite server are presented. The client and server nodes consist of a Transmission Control Protocol /Internet Protocol (TCP/IP) over ATM configuration. The ATM cells from the client or the server are transmitted to a gateway, packaged with some header information and transferred to a commercial LEO satellite constellation. These cells are then routed through the constellation to a gateway on the globe that allows the client/server communication to take place. Unspecified Bit Rate (UBR) is specified as the quality of service (QoS). Various data rates are considered.
Homemade Buckeye-Pi: A Learning Many-Node Platform for High-Performance Parallel Computing
NASA Astrophysics Data System (ADS)
Amooie, M. A.; Moortgat, J.
2017-12-01
We report on the "Buckeye-Pi" cluster, the supercomputer developed in The Ohio State University School of Earth Sciences from 128 inexpensive Raspberry Pi (RPi) 3 Model B single-board computers. Each RPi is equipped with fast Quad Core 1.2GHz ARMv8 64bit processor, 1GB of RAM, and 32GB microSD card for local storage. Therefore, the cluster has a total RAM of 128GB that is distributed on the individual nodes and a flash capacity of 4TB with 512 processors, while it benefits from low power consumption, easy portability, and low total cost. The cluster uses the Message Passing Interface protocol to manage the communications between each node. These features render our platform the most powerful RPi supercomputer to date and suitable for educational applications in high-performance-computing (HPC) and handling of large datasets. In particular, we use the Buckeye-Pi to implement optimized parallel codes in our in-house simulator for subsurface media flows with the goal of achieving a massively-parallelized scalable code. We present benchmarking results for the computational performance across various number of RPi nodes. We believe our project could inspire scientists and students to consider the proposed unconventional cluster architecture as a mainstream and a feasible learning platform for challenging engineering and scientific problems.
Cost-Effective Control of Infectious Disease Outbreaks Accounting for Societal Reaction.
Fast, Shannon M; González, Marta C; Markuzon, Natasha
2015-01-01
Studies of cost-effective disease prevention have typically focused on the tradeoff between the cost of disease transmission and the cost of applying control measures. We present a novel approach that also accounts for the cost of social disruptions resulting from the spread of disease. These disruptions, which we call social response, can include heightened anxiety, strain on healthcare infrastructure, economic losses, or violence. The spread of disease and social response are simulated under several different intervention strategies. The modeled social response depends upon the perceived risk of the disease, the extent of disease spread, and the media involvement. Using Monte Carlo simulation, we estimate the total number of infections and total social response for each strategy. We then identify the strategy that minimizes the expected total cost of the disease, which includes the cost of the disease itself, the cost of control measures, and the cost of social response. The model-based simulations suggest that the least-cost disease control strategy depends upon the perceived risk of the disease, as well as media intervention. The most cost-effective solution for diseases with low perceived risk was to implement moderate control measures. For diseases with higher perceived severity, such as SARS or Ebola, the most cost-effective strategy shifted toward intervening earlier in the outbreak, with greater resources. When intervention elicited increased media involvement, it remained important to control high severity diseases quickly. For moderate severity diseases, however, it became most cost-effective to implement no intervention and allow the disease to run its course. Our simulation results imply that, when diseases are perceived as severe, the costs of social response have a significant influence on selecting the most cost-effective strategy.
Cost-Effective Control of Infectious Disease Outbreaks Accounting for Societal Reaction
Fast, Shannon M.; González, Marta C.; Markuzon, Natasha
2015-01-01
Background Studies of cost-effective disease prevention have typically focused on the tradeoff between the cost of disease transmission and the cost of applying control measures. We present a novel approach that also accounts for the cost of social disruptions resulting from the spread of disease. These disruptions, which we call social response, can include heightened anxiety, strain on healthcare infrastructure, economic losses, or violence. Methodology The spread of disease and social response are simulated under several different intervention strategies. The modeled social response depends upon the perceived risk of the disease, the extent of disease spread, and the media involvement. Using Monte Carlo simulation, we estimate the total number of infections and total social response for each strategy. We then identify the strategy that minimizes the expected total cost of the disease, which includes the cost of the disease itself, the cost of control measures, and the cost of social response. Conclusions The model-based simulations suggest that the least-cost disease control strategy depends upon the perceived risk of the disease, as well as media intervention. The most cost-effective solution for diseases with low perceived risk was to implement moderate control measures. For diseases with higher perceived severity, such as SARS or Ebola, the most cost-effective strategy shifted toward intervening earlier in the outbreak, with greater resources. When intervention elicited increased media involvement, it remained important to control high severity diseases quickly. For moderate severity diseases, however, it became most cost-effective to implement no intervention and allow the disease to run its course. Our simulation results imply that, when diseases are perceived as severe, the costs of social response have a significant influence on selecting the most cost-effective strategy. PMID:26288274
"I got it on Ebay!": cost-effective approach to surgical skills laboratories.
Schneider, Ethan; Schenarts, Paul J; Shostrom, Valerie; Schenarts, Kimberly D; Evans, Charity H
2017-01-01
Surgical education is witnessing a surge in the use of simulation. However, implementation of simulation is often cost-prohibitive. Online shopping offers a low budget alternative. The aim of this study was to implement cost-effective skills laboratories and analyze online versus manufacturers' prices to evaluate for savings. Four skills laboratories were designed for the surgery clerkship from July 2014 to June 2015. Skills laboratories were implemented using hand-built simulation and instruments purchased online. Trademarked simulation was priced online and instruments priced from a manufacturer. Costs were compiled, and a descriptive cost analysis of online and manufacturers' prices was performed. Learners rated their level of satisfaction for all educational activities, and levels of satisfaction were compared. A total of 119 third-year medical students participated. Supply lists and costs were compiled for each laboratory. A descriptive cost analysis of online and manufacturers' prices showed online prices were substantially lower than manufacturers, with a per laboratory savings of: $1779.26 (suturing), $1752.52 (chest tube), $2448.52 (anastomosis), and $1891.64 (laparoscopic), resulting in a year 1 savings of $47,285. Mean student satisfaction scores for the skills laboratories were 4.32, with statistical significance compared to live lectures at 2.96 (P < 0.05) and small group activities at 3.67 (P < 0.05). A cost-effective approach for implementation of skills laboratories showed substantial savings. By using hand-built simulation boxes and online resources to purchase surgical equipment, surgical educators overcome financial obstacles limiting the use of simulation and provide learning opportunities that medical students perceive as beneficial. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Penny, Matthew T., E-mail: penny@astronomy.ohio-state.edu
2014-08-01
Extensive simulations of planetary microlensing are necessary both before and after a survey is conducted: before to design and optimize the survey and after to understand its detection efficiency. The major bottleneck in such computations is the computation of light curves. However, for low-mass planets, most of these computations are wasteful, as most light curves do not contain detectable planetary signatures. In this paper, I develop a parameterization of the binary microlens that is conducive to avoiding light curve computations. I empirically find analytic expressions describing the limits of the parameter space that contain the vast majority of low-mass planetmore » detections. Through a large-scale simulation, I measure the (in)completeness of the parameterization and the speed-up it is possible to achieve. For Earth-mass planets in a wide range of orbits, it is possible to speed up simulations by a factor of ∼30-125 (depending on the survey's annual duty-cycle) at the cost of missing ∼1% of detections (which is actually a smaller loss than for the arbitrary parameter limits typically applied in microlensing simulations). The benefits of the parameterization probably outweigh the costs for planets below 100 M{sub ⊕}. For planets at the sensitivity limit of AFTA-WFIRST, simulation speed-ups of a factor ∼1000 or more are possible.« less
Ansdell, Paul; Dekerle, Jeanne
2017-10-10
To investigate the development of neuromuscular fatigue during a basketball game simulation and ascertain whether sodium bicarbonate (NaHCO3) supplementation attenuates any neuromuscular fatigue that persists. Ten participants ingested 0.2 g.kg of NaHCO3 (or an equimolar placebo dosage of sodium chloride [NaCl]) 90 and 60 minutes prior to commencing a basketball game simulation (ALK-T vs PLA-T). Isometric maximal voluntary contractions of the knee extensors (MVIC) and potentiated high (100 Hz) and low (10 Hz) frequency doublet twitches were recorded before and after each match quarter for both trials. In addition, 15 m sprint times and layup completion (%) were recorded during each quarter. MVIC, 100 and 10 Hz twitch forces declined progressively in both trials (P<0.05) with a less pronounced decrease in MVIC during ALK-T (P<0.01). Both 100 and 10 Hz twitch forces were also significantly greater in ALK-T (P<0.05). 15 m sprint time increased over the course of both trials (∼2%, P<0.01); however, no significant condition or time effect was found for layup completion (P>0.05). A basketball simulation protocol induces a substantial amount of neuromuscular (reduction in knee extensor MVICs) and peripheral fatigue with a concomitant increase in 15 m sprint time over the protocol. NaHCO3 supplementation attenuated the rate of fatigue development by protecting contractile elements of the muscle fibres. This study provides coaches with information about the magnitude of fatigue induced by a simulated basketball game, and provides evidence of the efficacy of NaHCO3 in attenuating fatigue.
NASA Astrophysics Data System (ADS)
Fairbanks, Hillary R.; Doostan, Alireza; Ketelsen, Christian; Iaccarino, Gianluca
2017-07-01
Multilevel Monte Carlo (MLMC) is a recently proposed variation of Monte Carlo (MC) simulation that achieves variance reduction by simulating the governing equations on a series of spatial (or temporal) grids with increasing resolution. Instead of directly employing the fine grid solutions, MLMC estimates the expectation of the quantity of interest from the coarsest grid solutions as well as differences between each two consecutive grid solutions. When the differences corresponding to finer grids become smaller, hence less variable, fewer MC realizations of finer grid solutions are needed to compute the difference expectations, thus leading to a reduction in the overall work. This paper presents an extension of MLMC, referred to as multilevel control variates (MLCV), where a low-rank approximation to the solution on each grid, obtained primarily based on coarser grid solutions, is used as a control variate for estimating the expectations involved in MLMC. Cost estimates as well as numerical examples are presented to demonstrate the advantage of this new MLCV approach over the standard MLMC when the solution of interest admits a low-rank approximation and the cost of simulating finer grids grows fast.
Bruna, Ondřej; Levora, Tomáš; Holub, Jan
2018-05-08
Pilots of ultra light aircraft have limited training resources, but with the use of low cost simulators it might be possible to train and test some parts of their training on the ground. The purpose of this paper is to examine possibility of stress inducement on a low cost flight simulator. Stress is assessed from electrocardiogram and respiration. Engine failure during flight served as a stress inducement stimuli. For one flight, pilots had access to an emergency navigation system. There were recorded some statistically significant changes in parameters regarding breathing frequency. Although no significant change was observed in ECG parameters, there appears to be an effect on respiration parameters. Physiological signals processed with analysis of variance suggest, that the moment of engine failure and approach for landing affected average breathing frequency. Presence of navigation interface does not appear to have a significant effect on pilots.
Design and simulation of a sensor for heliostat field closed loop control
NASA Astrophysics Data System (ADS)
Collins, Mike; Potter, Daniel; Burton, Alex
2017-06-01
Significant research has been completed in pursuit of capital cost reductions for heliostats [1],[2]. The camera array closed loop control concept has potential to radically alter the way heliostats are controlled and installed by replacing high quality open loop targeting systems with low quality targeting devices that rely on measurement of image position to remove tracking errors during operation. Although the system could be used for any heliostat size, the system significantly benefits small heliostats by reducing actuation costs, enabling large numbers of heliostats to be calibrated simultaneously, and enabling calibration of heliostats that produce low irradiance (similar or less than ambient light images) on Lambertian calibration targets, such as small heliostats that are far from the tower. A simulation method for the camera array has been designed and verified experimentally. The simulation tool demonstrates that closed loop calibration or control is possible using this device.
Steenstra, Ivan A; Anema, Johannes R; Bongers, Paulien M; de Vet, Henrica C W; van Mechelen, Willem
2003-11-21
To describe the design of a population based randomized controlled trial (RCT), including a cost-effectiveness analysis, comparing participative ergonomics interventions between 2-8 weeks of sick leave and Graded Activity after 8 weeks of sick leave with usual care, in occupational back pain management. An RCT and cost-effectiveness evaluation in employees sick-listed for a period of 2 to 6 weeks due to low back pain. Interventions used are 1. Communication between general practitioner and occupational physician plus Participative Ergonomics protocol performed by an ergonomist. 2. Graded Activity based on cognitive behavioural principles by a physiotherapist. 3. Usual care, provided by an occupational physician according to the Dutch guidelines for the occupational health management of workers with low back pain. The primary outcome measure is return to work. Secondary outcome measures are pain intensity, functional status and general improvement. Intermediate variables are kinesiophobia and pain coping. The cost-effectiveness analysis includes the direct and indirect costs due to low back pain. The outcome measures are assessed before randomization (after 2-6 weeks on sick leave) and 12 weeks, 26 weeks and 52 weeks after first day of sick leave. The combination of these interventions has been subject of earlier research in Canada. The results of the current RCT will: 1. crossvalidate the Canadian findings in an different sociocultural environment; 2. add to the cost-effectiveness on treatment options for workers in the sub acute phase of low back pain. Results might lead to alterations of existing (inter)national guidelines.
Low-Cost Avionics Simulation for Aircrew Training.
ERIC Educational Resources Information Center
Edwards, Bernell J.
This report documents an experiment to determine the training effectiveness of a microcomputer-based avionics system trainer as a cost-effective alternative to training in the actual aircraft. Participants--26 operationally qualified C-141 pilots with no prior knowledge of the Fuel Saving Advisory System (FSAS), a computerized fuel management…
Temperature and Humidity Calibration of a Low-Cost Wireless Dust Sensor for Real-Time Monitoring.
Hojaiji, Hannaneh; Kalantarian, Haik; Bui, Alex A T; King, Christine E; Sarrafzadeh, Majid
2017-03-01
This paper introduces the design, calibration, and validation of a low-cost portable sensor for the real-time measurement of dust particles within the environment. The proposed design consists of low hardware cost and calibration based on temperature and humidity sensing to achieve accurate processing of airborne dust density. Using commercial particulate matter sensors, a highly accurate air quality monitoring sensor was designed and calibrated using real world variations in humidity and temperature for indoor and outdoor applications. Furthermore, to provide a low-cost secure solution for real-time data transfer and monitoring, an onboard Bluetooth module with AES data encryption protocol was implemented. The wireless sensor was tested against a Dylos DC1100 Pro Air Quality Monitor, as well as an Alphasense OPC-N2 optical air quality monitoring sensor for accuracy. The sensor was also tested for reliability by comparing the sensor to an exact copy of itself under indoor and outdoor conditions. It was found that accurate measurements under real-world humid and temperature varying and dynamically changing conditions were achievable using the proposed sensor when compared to the commercially available sensors. In addition to accurate and reliable sensing, this sensor was designed to be wearable and perform real-time data collection and transmission, making it easy to collect and analyze data for air quality monitoring and real-time feedback in remote health monitoring applications. Thus, the proposed device achieves high quality measurements at lower-cost solutions than commercially available wireless sensors for air quality.
An Efficient and QoS Supported Multichannel MAC Protocol for Vehicular Ad Hoc Networks
Tan, Guozhen; Yu, Chao
2017-01-01
Vehicular Ad Hoc Networks (VANETs) employ multichannel to provide a variety of safety and non-safety (transport efficiency and infotainment) applications, based on the IEEE 802.11p and IEEE 1609.4 protocols. Different types of applications require different levels Quality-of-Service (QoS) support. Recently, transport efficiency and infotainment applications (e.g., electronic map download and Internet access) have received more and more attention, and this kind of applications is expected to become a big market driver in a near future. In this paper, we propose an Efficient and QoS supported Multichannel Medium Access Control (EQM-MAC) protocol for VANETs in a highway environment. The EQM-MAC protocol utilizes the service channel resources for non-safety message transmissions during the whole synchronization interval, and it dynamically adjusts minimum contention window size for different non-safety services according to the traffic conditions. Theoretical model analysis and extensive simulation results show that the EQM-MAC protocol can support QoS services, while ensuring the high saturation throughput and low transmission delay for non-safety applications. PMID:28991217
Jiang, Ailian; Zheng, Lihong
2018-03-29
Low cost, high reliability and easy maintenance are key criteria in the design of routing protocols for wireless sensor networks (WSNs). This paper investigates the existing ant colony optimization (ACO)-based WSN routing algorithms and the minimum hop count WSN routing algorithms by reviewing their strengths and weaknesses. We also consider the critical factors of WSNs, such as energy constraint of sensor nodes, network load balancing and dynamic network topology. Then we propose a hybrid routing algorithm that integrates ACO and a minimum hop count scheme. The proposed algorithm is able to find the optimal routing path with minimal total energy consumption and balanced energy consumption on each node. The algorithm has unique superiority in terms of searching for the optimal path, balancing the network load and the network topology maintenance. The WSN model and the proposed algorithm have been implemented using C++. Extensive simulation experimental results have shown that our algorithm outperforms several other WSN routing algorithms on such aspects that include the rate of convergence, the success rate in searching for global optimal solution, and the network lifetime.
2018-01-01
Low cost, high reliability and easy maintenance are key criteria in the design of routing protocols for wireless sensor networks (WSNs). This paper investigates the existing ant colony optimization (ACO)-based WSN routing algorithms and the minimum hop count WSN routing algorithms by reviewing their strengths and weaknesses. We also consider the critical factors of WSNs, such as energy constraint of sensor nodes, network load balancing and dynamic network topology. Then we propose a hybrid routing algorithm that integrates ACO and a minimum hop count scheme. The proposed algorithm is able to find the optimal routing path with minimal total energy consumption and balanced energy consumption on each node. The algorithm has unique superiority in terms of searching for the optimal path, balancing the network load and the network topology maintenance. The WSN model and the proposed algorithm have been implemented using C++. Extensive simulation experimental results have shown that our algorithm outperforms several other WSN routing algorithms on such aspects that include the rate of convergence, the success rate in searching for global optimal solution, and the network lifetime. PMID:29596336
Robust Timing Synchronization in Aeronautical Mobile Communication Systems
NASA Technical Reports Server (NTRS)
Xiong, Fu-Qin; Pinchak, Stanley
2004-01-01
This work details a study of robust synchronization schemes suitable for satellite to mobile aeronautical applications. A new scheme, the Modified Sliding Window Synchronizer (MSWS), is devised and compared with existing schemes, including the traditional Early-Late Gate Synchronizer (ELGS), the Gardner Zero-Crossing Detector (GZCD), and the Sliding Window Synchronizer (SWS). Performance of the synchronization schemes is evaluated by a set of metrics that indicate performance in digital communications systems. The metrics are convergence time, mean square phase error (or root mean-square phase error), lowest SNR for locking, initial frequency offset performance, midstream frequency offset performance, and system complexity. The performance of the synchronizers is evaluated by means of Matlab simulation models. A simulation platform is devised to model the satellite to mobile aeronautical channel, consisting of a Quadrature Phase Shift Keying modulator, an additive white Gaussian noise channel, and a demodulator front end. Simulation results show that the MSWS provides the most robust performance at the cost of system complexity. The GZCD provides a good tradeoff between robustness and system complexity for communication systems that require high symbol rates or low overall system costs. The ELGS has a high system complexity despite its average performance. Overall, the SWS, originally designed for multi-carrier systems, performs very poorly in single-carrier communications systems. Table 5.1 in Section 5 provides a ranking of each of the synchronization schemes in terms of the metrics set forth in Section 4.1. Details of comparison are given in Section 5. Based on the results presented in Table 5, it is safe to say that the most robust synchronization scheme examined in this work is the high-sample-rate Modified Sliding Window Synchronizer. A close second is its low-sample-rate cousin. The tradeoff between complexity and lowest mean-square phase error determines the rankings of the Gardner Zero-Crossing Detector and both versions of the Early-Late Gate Synchronizer. The least robust models are the high and low-sample-rate Sliding Window Synchronizers. Consequently, the recommended replacement synchronizer for NASA's Advanced Air Transportation Technologies mobile aeronautical communications system is the high-sample-rate Modified Sliding Window Synchronizer. By incorporating this synchronizer into their system, NASA can be assured that their system will be operational in extremely adverse conditions. The quick convergence time of the MSWS should allow the use of high-level protocols. However, if NASA feels that reduced system complexity is the most important aspect of their replacement synchronizer, the Gardner Zero-Crossing Detector would be the best choice.
Li, Tao; Hauptmann, Jonas Rahlf; Wei, Zhongming; Petersen, Søren; Bovet, Nicolas; Vosch, Tom; Nygård, Jesper; Hu, Wenping; Liu, Yunqi; Bjørnholm, Thomas; Nørgaard, Kasper; Laursen, Bo W
2012-03-08
A novel method using solution-processed ultrathin chemically derived graphene films as soft top contacts for the non-destructive fabrication of molecular junctions is demonstrated. We believe this protocol will greatly enrich the solid-state test beds for molecular electronics due to its low-cost, easy-processing and flexible nature. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The BIMDA shuttle flight mission - A low cost MPS payload
NASA Technical Reports Server (NTRS)
Holemans, Jaak; Cassanto, John M.; Morrison, Dennis; Rose, Alan; Luttges, Marvin
1990-01-01
The design, operation, and experimental protocol of the Bioserve-ITA Materials Dispersion Apparatus Payload (BIMDA) to be flown on the Space Shuttle on STS-37 are described. The aim of BIMDA is to investigate the methods and commercial potential of biomedical and fluid science applications in the microgravity environment. The BIMDA payload operations are diagrammed, and the payload components and experiments are listed, including the investigators and sponsoring institutions.
1997-12-01
implement, they may also serve as interim measures for reducing risk prior to subsequent phytoremediation or remediation by other techniques. 2.0...are essentially non-leachable and pass leachate and TCLP testing protocols. 2.6 Time Requirements Most of the stabilization techniques mentioned above...site. In addition to the attractive low cost of both phytoremediation techniques, these techniques may also be less invasive and more quickly
Optimal setups for forced-choice staircases with fixed step sizes.
García-Pérez, M A
2000-01-01
Forced-choice staircases with fixed step sizes are used in a variety of formats whose relative merits have never been studied. This paper presents a comparative study aimed at determining their optimal format. Factors included in the study were the up/down rule, the length (number of reversals), and the size of the steps. The study also addressed the issue of whether a protocol involving three staircases running for N reversals each (with a subsequent average of the estimates provided by each individual staircase) has better statistical properties than an alternative protocol involving a single staircase running for 3N reversals. In all cases the size of a step up was different from that of a step down, in the appropriate ratio determined by García-Pérez (Vision Research, 1998, 38, 1861 - 1881). The results of a simulation study indicate that a) there are no conditions in which the 1-down/1-up rule is advisable; b) different combinations of up/down rule and number of reversals appear equivalent in terms of precision and cost: c) using a single long staircase with 3N reversals is more efficient than running three staircases with N reversals each: d) to avoid bias and attain sufficient accuracy, threshold estimates should be based on at least 30 reversals: and e) to avoid excessive cost and imprecision, the size of the step up should be between 2/3 and 3/3 the (known or presumed) spread of the psychometric function. An empirical study with human subjects confirmed the major characteristics revealed by the simulations.
The Cost-Effectiveness of an Intensive Treatment Protocol for Severe Dyslexia in Children
ERIC Educational Resources Information Center
Hakkaart-van Roijen, Leona; Goettsch, Wim G.; Ekkebus, Michel; Gerretsen, Patty; Stolk, Elly A.
2011-01-01
Studies of interventions for dyslexia have focused entirely on outcomes related to literacy. In this study, we considered a broader picture assessing improved quality of life compared with costs. A model served as a tool to compare costs and effects of treatment according to a new protocol and care as usual. Quality of life was measured and valued…
Scalability enhancement of AODV using local link repairing
NASA Astrophysics Data System (ADS)
Jain, Jyoti; Gupta, Roopam; Bandhopadhyay, T. K.
2014-09-01
Dynamic change in the topology of an ad hoc network makes it difficult to design an efficient routing protocol. Scalability of an ad hoc network is also one of the important criteria of research in this field. Most of the research works in ad hoc network focus on routing and medium access protocols and produce simulation results for limited-size networks. Ad hoc on-demand distance vector (AODV) is one of the best reactive routing protocols. In this article, modified routing protocols based on local link repairing of AODV are proposed. Method of finding alternate routes for next-to-next node is proposed in case of link failure. These protocols are beacon-less, means periodic hello message is removed from the basic AODV to improve scalability. Few control packet formats have been changed to accommodate suggested modification. Proposed protocols are simulated to investigate scalability performance and compared with basic AODV protocol. This also proves that local link repairing of proposed protocol improves scalability of the network. From simulation results, it is clear that scalability performance of routing protocol is improved because of link repairing method. We have tested protocols for different terrain area with approximate constant node densities and different traffic load.
Multifamily Housing Rehabilitation Process Improvements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sweet, Marshall L.; Francisco, Abby; Roberts, Sydney G.
Rea Ventures Group, LLC, (Rea Ventures) partnered with Southface Energy Institute (Southface) on the rehabilitation of 418 low-income rental multifamily apartments located at 14 different properties in Georgia (Climate Zones 2-4). These 22-year old, individually-metered units were arranged in rowhouse or townhouse style units. Rehabilitation plans were developed using a process prescribed by the US Department of Agriculture (USDA) Rural Development program, who partially funded the building upgrades. The USDA is responsible for building, upgrading, and subsidizing housing in rural areas nationwide. In 2012, over $100 million was allocated in grants and loans. Due to the unique financing mechanism asmore » well as long-term ownership requirements, property owners are especially motivated to invest in upgrades that will increase durability and tenant retention. These buildings represent a large stock of rural affordable housing that have the potential for significant energy and cost savings for property owners and tenants. Southface analyzed the energy upgrade potential of one stereotypical property in the Rea Ventures portfolio. This study will provide insight into the most cost-effective, implementable energy efficiency and durability upgrades for this age multifamily housing, having an enormous impact not only on the portfolio of Rea Ventures but on the vast USDA and larger Federal portfolio. Additionally, Southface will identify gaps in the current capital needs assessment process, examine available audit and simulation tools and protocols, and evaluate additional auditor training or certification needs.« less
Study of CdTe/CdS solar cell at low power density for low-illumination applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Devi, Nisha, E-mail: nishatanwer1989@gmail.com; Aziz, Anver, E-mail: aaziz@jmi.ac.in; Datta, Shouvik
In this paper, we numerically investigate CdTe/CdS PV cell properties using a simulation program Solar Cell Capacitance Simulator in 1D (SCAPS-1D). A simple structure of CdTe PV cell has been optimized to study the effect of temperature, absorber thickness and work function at very low incident power. Objective of this research paper is to build an efficient and cost effective solar cell for portable electronic devices such as portable computers and cell phones that work at low incident power because most of such devices work at diffused and reflected sunlight. In this report, we simulated a simple CdTe PV cellmore » at very low incident power, which gives good efficiency.« less
Kumar, Pardeep; Lee, Sang-Gon; Lee, Hoon-Jae
2012-01-01
A wireless medical sensor network (WMSN) can sense humans’ physiological signs without sacrificing patient comfort and transmit patient vital signs to health professionals’ hand-held devices. The patient physiological data are highly sensitive and WMSNs are extremely vulnerable to many attacks. Therefore, it must be ensured that patients’ medical signs are not exposed to unauthorized users. Consequently, strong user authentication is the main concern for the success and large scale deployment of WMSNs. In this regard, this paper presents an efficient, strong authentication protocol, named E-SAP, for healthcare application using WMSNs. The proposed E-SAP includes: (1) a two-factor (i.e., password and smartcard) professional authentication; (2) mutual authentication between the professional and the medical sensor; (3) symmetric encryption/decryption for providing message confidentiality; (4) establishment of a secure session key at the end of authentication; and (5) professionals can change their password. Further, the proposed protocol requires three message exchanges between the professional, medical sensor node and gateway node, and achieves efficiency (i.e., low computation and communication cost). Through the formal analysis, security analysis and performance analysis, we demonstrate that E-SAP is more secure against many practical attacks, and allows a tradeoff between the security and the performance cost for healthcare application using WMSNs. PMID:22438729
Kumar, Pardeep; Lee, Sang-Gon; Lee, Hoon-Jae
2012-01-01
A wireless medical sensor network (WMSN) can sense humans' physiological signs without sacrificing patient comfort and transmit patient vital signs to health professionals' hand-held devices. The patient physiological data are highly sensitive and WMSNs are extremely vulnerable to many attacks. Therefore, it must be ensured that patients' medical signs are not exposed to unauthorized users. Consequently, strong user authentication is the main concern for the success and large scale deployment of WMSNs. In this regard, this paper presents an efficient, strong authentication protocol, named E-SAP, for healthcare application using WMSNs. The proposed E-SAP includes: (1) a two-factor (i.e., password and smartcard) professional authentication; (2) mutual authentication between the professional and the medical sensor; (3) symmetric encryption/decryption for providing message confidentiality; (4) establishment of a secure session key at the end of authentication; and (5) professionals can change their password. Further, the proposed protocol requires three message exchanges between the professional, medical sensor node and gateway node, and achieves efficiency (i.e., low computation and communication cost). Through the formal analysis, security analysis and performance analysis, we demonstrate that E-SAP is more secure against many practical attacks, and allows a tradeoff between the security and the performance cost for healthcare application using WMSNs.
Museum genomics: low-cost and high-accuracy genetic data from historical specimens.
Rowe, Kevin C; Singhal, Sonal; Macmanes, Matthew D; Ayroles, Julien F; Morelli, Toni Lyn; Rubidge, Emily M; Bi, Ke; Moritz, Craig C
2011-11-01
Natural history collections are unparalleled repositories of geographical and temporal variation in faunal conditions. Molecular studies offer an opportunity to uncover much of this variation; however, genetic studies of historical museum specimens typically rely on extracting highly degraded and chemically modified DNA samples from skins, skulls or other dried samples. Despite this limitation, obtaining short fragments of DNA sequences using traditional PCR amplification of DNA has been the primary method for genetic study of historical specimens. Few laboratories have succeeded in obtaining genome-scale sequences from historical specimens and then only with considerable effort and cost. Here, we describe a low-cost approach using high-throughput next-generation sequencing to obtain reliable genome-scale sequence data from a traditionally preserved mammal skin and skull using a simple extraction protocol. We show that single-nucleotide polymorphisms (SNPs) from the genome sequences obtained independently from the skin and from the skull are highly repeatable compared to a reference genome. © 2011 Blackwell Publishing Ltd.
Cleemput, Irina; De Laet, Chris
2013-05-01
Treatment costs of end-stage renal disease with dialysis are high and vary between dialysis modalities. Public healthcare payers aim at stimulating the use of less expensive dialysis modalities, with maintenance of healthcare quality. This study examines the effects of Belgian financial incentive mechanisms for the use of low-cost dialysis treatments. First, the costs of different dialysis modalities were calculated from the hospital's perspective. Data were obtained through a hospital survey. The balance between costs and revenues was simulated for an average Belgian dialysis programme. Incremental profits were calculated in function of the proportion of patients on alternative dialysis modalities. Hospital haemodialysis is the most expensive modality per patient year, followed by peritoneal dialysis and finally satellite haemodialysis. Under current reimbursement rules mean profits of a dialysis programme are maximal if about 28% of patients are treated with a low-cost dialysis modality. This is only slightly lower than the observed percentage in Belgian dialysis centres in the same period. In Belgium, the financial incentives for the use of low-cost dialysis modalities only had a modest impact due to the continuing profits that could be generated by high-cost dialysis. Profit neutrality is crucial for the success of any financial incentive mechanism for low-cost dialysis modalities. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Cost effectiveness of a protocol using palivizumab in preterm infants.
Hernández-Gago, Yolanda; Lombardero-Pin, Marina; Ortega de la Cruz, Casilda; Maciuniak, Pablo A; Díez Del Pino, Alicia
2017-03-01
The main objective was to evaluate the cost-effectiveness of protocol use of palivizumab in premature established by consensus in our Hospital comparing it based on the recommendations of various Scientific Societies. As a secondary objective risk factors and severity of hospitalized patients attending the established protocol in our Hospital were analyzed. The study period was 4 seasons with the expanded protocol (retrospective data) versus 2 with restricted or agreed protocol (prospective data). The perspective of the study was the Health System, including the costs of hospitalization and palivizumab our center. The calculation of the effectiveness was determined with the admission rate of premature patients stratified by weeks of gestational age <29, <32; and <35. For the analysis of risk factors and severity in patients admitted seasons with the new protocol are collected prospectively clinical data and environmental and social factors. In the range of gestational age <29 years old and <32 greater effectiveness of the extended protocol was not demonstrated against the consensus. Only more effective for EG <35 in the accumulated data and comparing seasons 12/13 and 08/09 to 13/14 for individual data was observed. This range has an associated incremental cost effectiveness ratio of € 53 250,07 (range: € 14 793,39 to € 90 446,47 for singles data and € 50 525,53 (€ 28 688.22 to € 211 575,65) for accumulated. The establishment of this protocol in our center meant an average saving per season € 169 911,51. A cost-effectiveness of the extended protocol appropriate relationship is found if the cost of palivizumab per patient was less than € 1 206,67 (calculated for maximum use of the vial) and a higher rate of hospitalization of 9.21%. Children entering the season with the new protocol (season 12/13 and 13/14) are 63.4% in children under 3 months and 90% are term infants who do not belong to any population at risk, while many of them have associated risk factors you vary as have school-age siblings, rural residence, parental smoking, poor educational background of parents, lack of artificial feeding and family history of allergy. The consensus protocol has not been a significant increase in hospitalization rates in preterm infants <32 weeks gestational age patients. In those <35 has been observed a higher rate of hospitalization, with a very unfavorable cost-effectiveness for all clinical scenarios valued relationship. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Kaur, Amandeep; Isaranuwatchai, Wanrudee; Jaffer, Aliya; Ferguson, Genevieve; Abi-Jaoude, Alexxa; Johnson, Andrew; Hollenberg, Elisa; Wiljer, David
2018-03-29
Youth demonstrate a low propensity to seek help for mental health issues and exhibit low use of health services despite the high prevalence of mental health challenges in this population. Research has found that delivering interventions via the internet and mobile devices is an effective way to reach youth. Thought Spot, a Web- and mobile-based map, was developed to help transition-aged youth in postsecondary settings overcome barriers to help-seeking, thereby reducing the economic burden associated with untreated mental health issues. This paper presents the protocol for an economic evaluation that will be conducted in conjunction with a randomized controlled trial (RCT) to evaluate the effectiveness and cost of Thought Spot compared with usual care in terms of self-efficacy for mental health help-seeking among postsecondary students. A partially blinded RCT will be conducted to assess the impact of Thought Spot on the self-efficacy of students for mental health help-seeking. Students from 3 postsecondary institutions in Ontario, Canada will be randomly allocated to 1 of 2 intervention groups (resource pamphlet or Thought Spot) for 6 months. The economic evaluation will focus on the perspective of postsecondary institutions or other organizations interested in using Thought Spot. Costs and resources for operating and maintaining the platform will be reported and compared with the costs and resource needs associated with usual care. The primary outcome will be change in help-seeking intentions, measured using the General Help-Seeking Questionnaire. The cost-effectiveness of the intervention will be determined by calculating the incremental cost-effectiveness ratio, which will then be compared with willingness to pay. The RCT is scheduled to begin in February 2018 and will run for 6 months, after which the economic evaluation will be completed. We expect to demonstrate that Thought Spot is a cost-effective way to improve help-seeking intentions and encourage help-seeking behavior among postsecondary students. The findings of this study will help inform postsecondary institutions when they are allocating resources for mental health initiatives. ClinicalTrials.gov NCT03412461; https://clinicaltrials.gov/ct2/show/NCT03412461 (Archived at WebCite at http://www.webcitation.org/6xy5lWpnZ). ©Amandeep Kaur, Wanrudee Isaranuwatchai, Aliya Jaffer, Genevieve Ferguson, Alexxa Abi-Jaoude, Andrew Johnson, Elisa Hollenberg, David Wiljer. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 29.03.2018.
NASA Astrophysics Data System (ADS)
Serbu, Sabina; Rivière, Étienne; Felber, Pascal
The emergence of large-scale distributed applications based on many-to-many communication models, e.g., broadcast and decentralized group communication, has an important impact on the underlying layers, notably the Internet routing infrastructure. To make an effective use of network resources, protocols should both limit the stress (amount of messages) on each infrastructure entity like routers and links, and balance as much as possible the load in the network. Most protocols use application-level metrics such as delays to improve efficiency of content dissemination or routing, but the extend to which such application-centric optimizations help reduce and balance the load imposed to the infrastructure is unclear. In this paper, we elaborate on the design of such network-friendly protocols and associated metrics. More specifically, we investigate random-based gossip dissemination. We propose and evaluate different ways of making this representative protocol network-friendly while keeping its desirable properties (robustness and low delays). Simulations of the proposed methods using synthetic and real network topologies convey and compare their abilities to reduce and balance the load while keeping good performance.
Bantam System Technology Project
NASA Technical Reports Server (NTRS)
Moon, J. M.; Beveridge, J. R.
1998-01-01
This report focuses on determining a best value, low risk, low cost and highly reliable Data and Command System for support of the launch of low cost vehicles which are to carry small payloads into low earth orbit. The ground-based DCS is considered as a component of the overall ground and flight support system which includes the DCS, flight computer, mission planning system and simulator. Interfaces between the DCS and these other component systems are considered. Consideration is also given to the operational aspects of the mission and of the DCS selected. This project involved: defining requirements, defining an efficient operations concept, defining a DCS architecture which satisfies the requirements and concept, conducting a market survey of commercial and government off-the-shelf DCS candidate systems and rating the candidate systems against the requirements/concept. The primary conclusions are that several low cost, off-the-shelf DCS solutions exist and these can be employed to provide for very low cost operations and low recurring maintenance cost. The primary recommendation is that the DCS design/specification should be integrated within the ground and flight support system design as early as possible to ensure ease of interoperability and efficient allocation of automation functions among the component systems.
NASA Technical Reports Server (NTRS)
Castiel, David
1991-01-01
On 5 Nov. 1990, Ellipsat filed with the FCC the first application to provide voice communication services via low earth orbiting (LEO) satellites. The proposed system, ELLIPSO, aims at achieving end-user costs comparable to those in the cellular industry. On 3 Jun. 1991 Ellipsat filed for the second complement of its system. Ellipsat was also the first company to propose combined position determination and mobile voice services via low-earth orbiting satellites. Ellipsat is still the only proponent of elliptical orbits for any commercial system in the United States. ELLIPSO uses a spectrum efficient combination of FDMA and CDMA techniques. Ellipsat's strategy is to tailor required capacity to user demand, reduce initial system costs and investment risks, and allow the provision of services at affordable end-user prices. ELLIPSO offers optimum features in all the components of its system, elliptical orbits, small satellites, integrated protocol and signalling system, integrated end-user electronics, novel marketing approach based on the cooperation with the tenets of mobile communications, end-user costs that are affordable, and a low risk approach as deployment is tailored to the growth of its customer base. The efficient design of the ELLIPSO constellation and system allows estimated end-user costs in the $.50 per minute range, five to six times less than any other system of comparable capability.
Evaluation of a Drag-Free Control Concept for Missions in Low Earth Orbit
NASA Technical Reports Server (NTRS)
Fleck, Melissa E.; Starin, Scott R.
2003-01-01
Atmospheric drag causes the greatest uncertainty in the equations of motion for spacecraft in Low Earth Orbit (LEO). If atmospheric drag eflects can be continuously and autonomously counteracted through the use of a drag-fee control system, drag may essentially be eliminated from the equations of motion for the spacecraft. The main perturbations on the spacecraft will then be those due to the gravitational field, which are much more easily predicted Through dynamical analysis and numerical simulation, this paper presents some potential costs and benefits associated with the fuel used during continuous drag compensation. In light of this cost-benefit analysis, simulation results are used to validate the concept of drag-free control for LEO spacecraft missions having certain characteristics.
Simões, Alyne; Eduardo, Fernanda P; Luiz, Ana Claudia; Campos, Luana; Sá, Pedro Henrique R N; Cristófaro, Márcio; Marques, Márcia M; Eduardo, Carlos P
2009-04-01
Oral mucositis is a dose-limiting and painful side effect of radiotherapy (RT) and/or chemotherapy in cancer patients. The purpose of the present study was to analyze the effect of different protocols of laser phototherapy (LPT) on the grade of mucositis and degree of pain in patients under RT. Thirty-nine patients were divided into three groups: G1, where the irradiations were done three times a week using low power laser; G2, where combined high and low power lasers were used three time a week; and G3, where patients received low power laser irradiation once a week. The low power LPT was done using an InGaAlP laser (660 nm/40 mW/6 J cm(-2)/0.24 J per point). In the combined protocol, the high power LPT was done using a GaAlAs laser (808 nm, 1 W/cm(2)). Oral mucositis was assessed at each LPT session in accordance to the oral-mucositis scale of the National Institute of the Cancer-Common Toxicity criteria (NIC-CTC). The patient self-assessed pain was measured by means of the visual analogue scale. All protocols of LPT led to the maintenance of oral mucositis scores in the same levels until the last RT session. Moreover, LPT three times a week also maintained the pain levels. However, the patients submitted to the once a week LPT had significant pain increase; and the association of low/high LPT led to increased healing time. These findings are desired when dealing with oncologic patients under RT avoiding unplanned radiation treatment breaks and additional hospital costs.
NASA Astrophysics Data System (ADS)
Yan, Hao; Cervino, Laura; Jia, Xun; Jiang, Steve B.
2012-04-01
While compressed sensing (CS)-based algorithms have been developed for the low-dose cone beam CT (CBCT) reconstruction, a clear understanding of the relationship between the image quality and imaging dose at low-dose levels is needed. In this paper, we qualitatively investigate this subject in a comprehensive manner with extensive experimental and simulation studies. The basic idea is to plot both the image quality and imaging dose together as functions of the number of projections and mAs per projection over the whole clinically relevant range. On this basis, a clear understanding of the tradeoff between the image quality and imaging dose can be achieved and optimal low-dose CBCT scan protocols can be developed to maximize the dose reduction while minimizing the image quality loss for various imaging tasks in image-guided radiation therapy (IGRT). Main findings of this work include (1) under the CS-based reconstruction framework, image quality has little degradation over a large range of dose variation. Image quality degradation becomes evident when the imaging dose (approximated with the x-ray tube load) is decreased below 100 total mAs. An imaging dose lower than 40 total mAs leads to a dramatic image degradation, and thus should be used cautiously. Optimal low-dose CBCT scan protocols likely fall in the dose range of 40-100 total mAs, depending on the specific IGRT applications. (2) Among different scan protocols at a constant low-dose level, the super sparse-view reconstruction with the projection number less than 50 is the most challenging case, even with strong regularization. Better image quality can be acquired with low mAs protocols. (3) The optimal scan protocol is the combination of a medium number of projections and a medium level of mAs/view. This is more evident when the dose is around 72.8 total mAs or below and when the ROI is a low-contrast or high-resolution object. Based on our results, the optimal number of projections is around 90 to 120. (4) The clinically acceptable lowest imaging dose level is task dependent. In our study, 72.8 mAs is a safe dose level for visualizing low-contrast objects, while 12.2 total mAs is sufficient for detecting high-contrast objects of diameter greater than 3 mm.
The use of a photoionization detector to detect harmful volatile chemicals by emergency personnel
Patel, Neil D; Fales, William D; Farrell, Robert N
2009-01-01
Objective The objective of this investigation was to determine if a photoionization detector (PID) could be used to detect the presence of a simulated harmful chemical on simulated casualties of a chemical release. Methods A screening protocol, based on existing radiation screening protocols, was developed for the purposes of the investigation. Three simulated casualties were contaminated with a simulated chemical agent and two groups of emergency responders were involved in the trials. The success–failure ratio of the participants was used to judge the performance of the PID in this application. Results A high success rate was observed when the screening protocol was properly adhered to (97.67%). Conversely, the success rate suffered when participants deviated from the protocol (86.31%). With one exception, all failures were noted to have been the result of a failure to correctly observe the established screening protocol. Conclusions The results of this investigation indicate that the PID may be an effective screening tool for emergency responders. However, additional study is necessary to both confirm the effectiveness of the PID and refine the screening protocol if necessary. PMID:27147829
PET-CT in oncological patients: analysis of informal care costs in cost-benefit assessment.
Orlacchio, Antonio; Ciarrapico, Anna Micaela; Schillaci, Orazio; Chegai, Fabrizio; Tosti, Daniela; D'Alba, Fabrizio; Guazzaroni, Manlio; Simonetti, Giovanni
2014-04-01
The authors analysed the impact of nonmedical costs (travel, loss of productivity) in an economic analysis of PET-CT (positron-emission tomography-computed tomography) performed with standard contrast-enhanced CT protocols (CECT). From October to November 2009, a total of 100 patients referred to our institute were administered a questionnaire to evaluate the nonmedical costs of PET-CT. In addition, the medical costs (equipment maintenance and depreciation, consumables and staff) related to PET-CT performed with CECT and PET-CT with low-dose nonenhanced CT and separate CECT were also estimated. The medical costs were 919.3 euro for PET-CT with separate CECT, and 801.3 euro for PET-CT with CECT. Therefore, savings of approximately 13% are possible. Moreover, savings in nonmedical costs can be achieved by reducing the number of hospital visits required by patients undergoing diagnostic imaging. Nonmedical costs heavily affect patients' finances as well as having an indirect impact on national health expenditure. Our results show that PET-CT performed with standard dose CECT in a single session provides benefits in terms of both medical and nonmedical costs.
Ablative material testing for low-pressure, low-cost rocket engines
NASA Technical Reports Server (NTRS)
Richter, G. Paul; Smith, Timothy D.
1995-01-01
The results of an experimental evaluation of ablative materials suitable for the production of light weight, low cost rocket engine combustion chambers and nozzles are presented. Ten individual specimens of four different compositions of silica cloth-reinforced phenolic resin materials were evaluated for comparative erosion in a subscale rocket engine combustion chamber. Gaseous hydrogen and gaseous oxygen were used as propellants, operating at a nominal chamber pressure of 1138 kPa (165 psi) and a nominal mixture ratio (O/F) of 3.3. These conditions were used to thermally simulate operation with RP-1 and liquid oxygen, and achieved a specimen throat gas temperature of approximately 2456 K (4420 R). Two high-density composition materials exhibited high erosion resistance, while two low-density compositions exhibited approximately 6-75 times lower average erosion resistance. The results compare favorably with previous testing by NASA and provide adequate data for selection of ablatives for low pressure, low cost rocket engines.
An economic evaluation of highly purified HMG and recombinant FSH based on a large randomized trial.
Wechowski, Jaroslaw; Connolly, Mark; McEwan, Philip; Kennedy, Richard
2007-11-01
Public funding for IVF is increasingly being challenged by health authorities in an attempt to minimize health service costs. In light of treatment rationing, the need to consider costs in relation to outcomes is paramount. To assess the cost implications of gonadotrophin treatment options, an economic evaluation comparing highly purified human menopausal gonadotrophin (HP-HMG) and recombinant FSH (rFSH) has been conducted. The analysis is based on individual patient data from a large randomized controlled trial (n = 731) in a long agonist IVF protocol. The economic evaluation uses a discrete event simulation model to assess treatment costs in relation to live births for both treatments based on published UK costs. After one cycle the mean costs per IVF treatment for HP-HMG and rFSH were pound2396 (95% CI pound2383-2414) and pound2633 ( pound2615-2652), respectively. The average cost-saving of pound237 per IVF cycle using HP-HMG allows one additional cycle to be delivered for every 10 cycles. With maternal and neonatal costs applied, the median cost per IVF baby delivered with HP-HMG was pound8893 compared with pound11,741 for rFSH (P < 0.001). The cost-saving potential of HP-HMG in IVF was still apparent after varying critical cost parameters in the probabilistic sensitivity analysis.
Promoting adverse drug reaction reporting: comparison of different approaches
Ribeiro-Vaz, Inês; Santos, Cristina Costa; Cruz-Correia, Ricardo
2016-01-01
ABSTRACT OBJECTIVE To describe different approaches to promote adverse drug reaction reporting among health care professionals, determining their cost-effectiveness. METHODS We analyzed and compared several approaches taken by the Northern Pharmacovigilance Centre (Portugal) to promote adverse drug reaction reporting. Approaches were compared regarding the number and relevance of adverse drug reaction reports obtained and costs involved. Costs by report were estimated by adding the initial costs and the running costs of each intervention. These costs were divided by the number of reports obtained with each intervention, to assess its cost-effectiveness. RESULTS All the approaches seem to have increased the number of adverse drug reaction reports. We noted the biggest increase with protocols (321 reports, costing 1.96 € each), followed by first educational approach (265 reports, 20.31 €/report) and by the hyperlink approach (136 reports, 15.59 €/report). Regarding the severity of adverse drug reactions, protocols were the most efficient approach, costing 2.29 €/report, followed by hyperlinks (30.28 €/report, having no running costs). Concerning unexpected adverse drug reactions, the best result was obtained with protocols (5.12 €/report), followed by first educational approach (38.79 €/report). CONCLUSIONS We recommend implementing protocols in other pharmacovigilance centers. They seem to be the most efficient intervention, allowing receiving adverse drug reactions reports at lower costs. The increase applied not only to the total number of reports, but also to the severity, unexpectedness and high degree of causality attributed to the adverse drug reactions. Still, hyperlinks have the advantage of not involving running costs, showing the second best performance in cost per adverse drug reactions report. PMID:27143614
Systemic and local reactions of bee venom immunotherapy in Iran.
Bemanian, Mohammad Hassan; Farhoudi, Abolhassan; Pourpak, Zahra; Gharagozlou, Mohammad; Movahedi, Masoud; Nabavi, Mohammad; Mozafari, Habibeh; Mohammadzadeh, Iraj; Chavoshzadeh, Zahra; Shirkhoda, Zahra
2007-12-01
Severe allergic reactions during specific immunotherapy may occur in the treatment of hymenoptera sting allergy. The objective of the present study was to examine the characteristics of allergic reactions during specific immunotherapy in patients with allergy towards hymenoptera venom in the Iranian population. A prospective study was performed using the clinical reports of 27 patients with anaphylaxis to bee venom (Apis melifera, Geupes vespula and Geupes Polites). Ten patients treated with Cluster protocol during 2002 and 2006 After diagnosis of hymenoptera sting allergy according to history and intradermal tests, the patient were treated with Cluster protocol immunotherapy. The protocol lasted 6 weeks with an increase in the concentration of venom from 0.01 microg/ml to 100 microg/ml. None of the patient received premedication. All patients with hymenoptera venom allergy received 120 injections. Anaphylactic reactions were classified according to the Mueller-classification. The frequencies of systemic reactions during Cluster protocol were 8.33% and 5% for yellow jacket and honey bee venom respectively. No patient experienced severe systemic reaction. Cluster protocol for hymenoptera immunotherapy is a reliable method for the treatment of anaphylactic reactions to bee venom. It is safe with low cost and do not need hospitalization.
Addition of senna improves quality of colonoscopy preparation with magnesium citrate.
Vradelis, Stergios; Kalaitzakis, Evangelos; Sharifi, Yalda; Buchel, Otto; Keshav, Satish; Chapman, Roger W; Braden, Barbara
2009-04-14
To prospectively investigate the effectiveness and patient's tolerance of two low-cost bowel cleansing preparation protocols based on magnesium citrate only or the combination of magnesium citrate and senna. A total of 342 patients who were referred for colonoscopy underwent a colon cleansing protocol with magnesium citrate alone (n = 160) or magnesium citrate and senna granules (n = 182). The colonoscopist rated the overall efficacy of colon cleansing using an established score on a 4-point scale. Patients were questioned before undergoing colonoscopy for side effects and symptoms during bowel preparation. The percentage of procedures rescheduled because of insufficient colon cleansing was 7% in the magnesium citrate group and 4% in the magnesium citrate/senna group (P = 0.44). Adequate visualization of the colonic mucosa was rated superior under the citramag/senna regimen (P = 0.004). Both regimens were well tolerated, and did not significantly differ in the occurrence of nausea, bloating or headache. However, abdominal cramps were observed more often under the senna protocol (29.2%) compared to the magnesium citrate only protocol (9.9%, P < 0.0003). The addition of senna to the bowel preparation protocol with magnesium citrate significantly improves the cleansing outcome.
Addition of senna improves quality of colonoscopy preparation with magnesium citrate
Vradelis, Stergios; Kalaitzakis, Evangelos; Sharifi, Yalda; Buchel, Otto; Keshav, Satish; Chapman, Roger W; Braden, Barbara
2009-01-01
AIM: To prospectively investigate the effectiveness and patient’s tolerance of two low-cost bowel cleansing preparation protocols based on magnesium citrate only or the combination of magnesium citrate and senna. METHODS: A total of 342 patients who were referred for colonoscopy underwent a colon cleansing protocol with magnesium citrate alone (n = 160) or magnesium citrate and senna granules (n = 182). The colonoscopist rated the overall efficacy of colon cleansing using an established score on a 4-point scale. Patients were questioned before undergoing colonoscopy for side effects and symptoms during bowel preparation. RESULTS: The percentage of procedures rescheduled because of insufficient colon cleansing was 7% in the magnesium citrate group and 4% in the magnesium citrate/senna group (P = 0.44). Adequate visualization of the colonic mucosa was rated superior under the citramag/senna regimen (P = 0.004). Both regimens were well tolerated, and did not significantly differ in the occurrence of nausea, bloating or headache. However, abdominal cramps were observed more often under the senna protocol (29.2%) compared to the magnesium citrate only protocol (9.9%, P < 0.0003). CONCLUSION: The addition of senna to the bowel preparation protocol with magnesium citrate significantly improves the cleansing outcome. PMID:19360920
Droplet-based pyrosequencing using digital microfluidics.
Boles, Deborah J; Benton, Jonathan L; Siew, Germaine J; Levy, Miriam H; Thwar, Prasanna K; Sandahl, Melissa A; Rouse, Jeremy L; Perkins, Lisa C; Sudarsan, Arjun P; Jalili, Roxana; Pamula, Vamsee K; Srinivasan, Vijay; Fair, Richard B; Griffin, Peter B; Eckhardt, Allen E; Pollack, Michael G
2011-11-15
The feasibility of implementing pyrosequencing chemistry within droplets using electrowetting-based digital microfluidics is reported. An array of electrodes patterned on a printed-circuit board was used to control the formation, transportation, merging, mixing, and splitting of submicroliter-sized droplets contained within an oil-filled chamber. A three-enzyme pyrosequencing protocol was implemented in which individual droplets contained enzymes, deoxyribonucleotide triphosphates (dNTPs), and DNA templates. The DNA templates were anchored to magnetic beads which enabled them to be thoroughly washed between nucleotide additions. Reagents and protocols were optimized to maximize signal over background, linearity of response, cycle efficiency, and wash efficiency. As an initial demonstration of feasibility, a portion of a 229 bp Candida parapsilosis template was sequenced using both a de novo protocol and a resequencing protocol. The resequencing protocol generated over 60 bp of sequence with 100% sequence accuracy based on raw pyrogram levels. Excellent linearity was observed for all of the homopolymers (two, three, or four nucleotides) contained in the C. parapsilosis sequence. With improvements in microfluidic design it is expected that longer reads, higher throughput, and improved process integration (i.e., "sample-to-sequence" capability) could eventually be achieved using this low-cost platform.
Droplet-Based Pyrosequencing Using Digital Microfluidics
Boles, Deborah J.; Benton, Jonathan L.; Siew, Germaine J.; Levy, Miriam H.; Thwar, Prasanna K.; Sandahl, Melissa A.; Rouse, Jeremy L.; Perkins, Lisa C.; Sudarsan, Arjun P.; Jalili, Roxana; Pamula, Vamsee K.; Srinivasan, Vijay; Fair, Richard B.; Griffin, Peter B.; Eckhardt, Allen E.; Pollack, Michael G.
2013-01-01
The feasibility of implementing pyrosequencing chemistry within droplets using electrowetting-based digital microfluidics is reported. An array of electrodes patterned on a printed-circuit board was used to control the formation, transportation, merging, mixing, and splitting of submicroliter-sized droplets contained within an oil-filled chamber. A three-enzyme pyrosequencing protocol was implemented in which individual droplets contained enzymes, deoxyribonucleotide triphosphates (dNTPs), and DNA templates. The DNA templates were anchored to magnetic beads which enabled them to be thoroughly washed between nucleotide additions. Reagents and protocols were optimized to maximize signal over background, linearity of response, cycle efficiency, and wash efficiency. As an initial demonstration of feasibility, a portion of a 229 bp Candida parapsilosis template was sequenced using both a de novo protocol and a resequencing protocol. The resequencing protocol generated over 60 bp of sequence with 100% sequence accuracy based on raw pyrogram levels. Excellent linearity was observed for all of the homopolymers (two, three, or four nucleotides) contained in the C. parapsilosis sequence. With improvements in microfluidic design it is expected that longer reads, higher throughput, and improved process integration (i.e., “sample-to-sequence” capability) could eventually be achieved using this low-cost platform. PMID:21932784
NASA Astrophysics Data System (ADS)
Armeli Minicante, S.; Ambrosi, E.; Back, M.; Barichello, J.; Cattaruzza, E.; Gonella, F.; Scantamburlo, E.; Trave, E.
2016-07-01
Seaweeds are a reserve of natural dyes (chlorophylls a, b and c), characterized by low cost and easy supply, without potential environmental load in terms of land subtraction, and also complying with the requirements of an efficient waste management policy. In particular, the brown seaweed Undaria pinnatifida is a species largely present in the Venice Lagoon area, and for it a removal strategy is actually mandatory. In this paper, we set-up an eco-protocol for the best extraction and preparation procedures of the pigment, with the aim of finding an easy and affordable method for chlorophyll c extraction, exploring at the same time the possibility of using these algae within local sustainable management integrated strategies, among which the possible use of chlorophylls as a dye source in dye sensitized solar cells (DSSCs) is investigated. Experimental results suggest that the developed protocols are useful to optimize the chlorophyll c extraction, as shown by optical absorption spectroscopy measurements. The DSSCs built with the chlorophyll extracted by the proposed eco-protocol exhibit solar energy conversion efficiencies are similar to those obtained following extraction protocols with larger environmental impacts.
Cost-effectiveness of risk stratified followup after urethral reconstruction: a decision analysis.
Belsante, Michael J; Zhao, Lee C; Hudak, Steven J; Lotan, Yair; Morey, Allen F
2013-10-01
We propose a novel risk stratified followup protocol for use after urethroplasty and explore potential cost savings. Decision analysis was performed comparing a symptom based, risk stratified protocol for patients undergoing excision and primary anastomosis urethroplasty vs a standard regimen of close followup for urethroplasty. Model assumptions included that excision and primary anastomosis has a 94% success rate, 11% of patients with successful urethroplasty had persistent lower urinary tract symptoms requiring cystoscopic evaluation, patients in whom treatment failed undergo urethrotomy and patients with recurrence on symptom based surveillance have a delayed diagnosis requiring suprapubic tube drainage. The Nationwide Inpatient Sample from 2010 was queried to identify the number of urethroplasties performed per year in the United States. Costs were obtained based on Medicare reimbursement rates. The 5-year cost of a symptom based, risk stratified followup protocol is $430 per patient vs $2,827 per patient using standard close followup practice. An estimated 7,761 urethroplasties were performed in the United States in 2010. Assuming that 60% were excision and primary anastomosis, and with more than 5 years of followup, the risk stratified protocol was projected to yield an estimated savings of $11,165,130. Sensitivity analysis showed that the symptom based, risk stratified followup protocol was far more cost-effective than standard close followup in all settings. Less than 1% of patients would be expected to have an asymptomatic recurrence using the risk stratified followup protocol. A risk stratified, symptom based approach to urethroplasty followup would produce a significant reduction in health care costs while decreasing unnecessary followup visits, invasive testing and radiation exposure. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.