Sample records for lowest threshold current

  1. Thresholds for activation of rabbit retinal ganglion cells with an ultrafine, extracellular microelectrode.

    PubMed

    Jensen, Ralph J; Rizzo, Joseph F; Ziv, Ofer R; Grumet, Andrew; Wyatt, John

    2003-08-01

    To determine electrical thresholds required for extracellular activation of retinal ganglion cells as part of a project to develop an epiretinal prosthesis. Retinal ganglion cells were recorded extracellularly in retinas isolated from adult New Zealand White rabbits. Electrical current pulses of 100- micro s duration were delivered to the inner surface of the retina from a 5- micro m long electrode. In about half of the cells, the point of lowest threshold was found by searching with anodal current pulses; in the other cells, cathodal current pulses were used. Threshold measurements were obtained near the cell bodies of 20 ganglion cells and near the axons of 19 ganglion cells. Both cathodal and anodal stimuli evoked a neural response in the ganglion cells that consisted of a single action potential of near-constant latency that persisted when retinal synaptic transmission was blocked with cadmium chloride. For cell bodies, but not axons, thresholds for both cathodal and anodal stimulation were dependent on the search method used to find the point of lowest threshold. With search and stimulation of matching polarity, cathodal stimuli evoked a ganglion cell response at lower currents (approximately one seventh to one tenth axonal threshold) than did anodal stimuli for both cell bodies and axons. With cathodal search and stimulation, cell body median thresholds were somewhat lower (approximately one half) than the axonal median thresholds. With anodal search and stimulation, cell body median thresholds were approximately the same as axonal median thresholds. The results suggest that cathodal stimulation should produce lower thresholds, more localized stimulation, and somewhat better selectivity for cell bodies over axons than would anodal stimulation.

  2. Transcranial electric stimulation for intraoperative motor evoked potential monitoring: dependence of required stimulation current on interstimulus interval value.

    PubMed

    Joksimovic, Boban; Szelenyi, Andrea; Seifert, Volker; Damjanovic, Aleksandar; Damjanovic, Aleksandra; Rasulic, Lukas

    2015-05-01

    To evaluate the relationship between stimulus intensity by constant current transcranial electric stimulation and interstimulus interval (ISI) for eliciting muscle motor evoked potentials (MEPs) in three different hand muscles and the tibialis anterior muscles. We tested intraoperatively different monophasic constant current pulses and ISIs in 22 patients with clinically normal motor function. Motor thresholds of contralateral muscle MEPs were determined at 0.5 milliseconds (ms) pulse duration and ISIs of 1, 2, 3, 4, 5, and 10 ms using a train of 2, 3, and 5 monophasic constant current pulses of 62 to 104 mA before craniotomy and after closure of the dura mater. The lowest stimulation threshold to elicit MEPs in the examined muscles was achieved with a train of 5 pulses (ISI: 3 ms) before craniotomy, which was statistically significant compared with 2 pulses (ISI: 3 ms) as well as 3 pulses (ISIs: 3 and 10 ms). An ISI of 3 ms gave the lowest motor thresholds with statistical significance compared with the ISIs of 4 ms (2 pulses) and of 1 ms (3 pulses). All current intensity (mA) and ISI (ms) relationship graphs had a trend of the exponential function as y = a + bx + c ρ (x), where y is intensity (mA) and x is ISI (ms). The minimum of the function was determined for each patient and each muscle. The difference was statistically significant between 3 and 5 pulses before craniotomy and between 3 and 5 pulses and 2 and 5 pulses after closure of the dura mater. In adult neurosurgical patients with a normal motor status, a train of 5 pulses and an ISI of 3 ms provide the lowest motor thresholds. We provided evidence of the dependence of required stimulation current on ISI. Georg Thieme Verlag KG Stuttgart · New York.

  3. Identifying cochlear implant channels with poor electrode-neuron interface: partial tripolar, single-channel thresholds and psychophysical tuning curves.

    PubMed

    Bierer, Julie Arenberg; Faulkner, Kathleen F

    2010-04-01

    The goal of this study was to evaluate the ability of a threshold measure, made with a restricted electrode configuration, to identify channels exhibiting relatively poor spatial selectivity. With a restricted electrode configuration, channel-to-channel variability in threshold may reflect variations in the interface between the electrodes and auditory neurons (i.e., nerve survival, electrode placement, and tissue impedance). These variations in the electrode-neuron interface should also be reflected in psychophysical tuning curve (PTC) measurements. Specifically, it is hypothesized that high single-channel thresholds obtained with the spatially focused partial tripolar (pTP) electrode configuration are predictive of wide or tip-shifted PTCs. Data were collected from five cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp., Sylmar, CA). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the pTP configuration for which a fraction of current (sigma) from a center-active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. Forward-masked PTCs were obtained for channels with the highest, lowest, and median tripolar (sigma = 1 or 0.9) thresholds. The probe channel and level were fixed and presented with either the monopolar (sigma = 0) or a more focused pTP (sigma > or = 0.55) configuration. The masker channel and level were varied, whereas the configuration was fixed to sigma = 0.5. A standard, three-interval, two-alternative forced choice procedure was used for thresholds and masked levels. Single-channel threshold and variability in threshold across channels systematically increased as the compensating current, sigma, increased and the presumed electrical field became more focused. Across subjects, channels with the highest single-channel thresholds, when measured with a narrow, pTP stimulus, had significantly broader PTCs than the lowest threshold channels. In two subjects, the tips of the tuning curves were shifted away from the probe channel. Tuning curves were also wider for the monopolar probes than with pTP probes for both the highest and lowest threshold channels. These results suggest that single-channel thresholds measured with a restricted stimulus can be used to identify cochlear implant channels with poor spatial selectivity. Channels having wide or tip-shifted tuning characteristics would likely not deliver the appropriate spectral information to the intended auditory neurons, leading to suboptimal perception. As a clinical tool, quick identification of impaired channels could lead to patient-specific mapping strategies and result in improved speech and music perception.

  4. Identifying cochlear implant channels with poor electrode-neuron interface: partial tripolar, single-channel thresholds and psychophysical tuning curves

    PubMed Central

    Bierer, Julie Arenberg; Faulkner, Kathleen F.

    2010-01-01

    Objectives The goal of this study was to evaluate the ability of a threshold measure, made with a restricted electrode configuration, to identify channels exhibiting relatively poor spatial selectivity. With a restricted electrode configuration, channel-to-channel variability in threshold may reflect variations in the interface between the electrodes and auditory neurons (i.e., nerve survival, electrode placement, tissue impedance). These variations in the electrode-neuron interface should also be reflected in psychophysical tuning curve measurements. Specifically, it is hypothesized that high single-channel thresholds obtained with the spatially focused partial tripolar electrode configuration are predictive of wide or tip-shifted psychophysical tuning curves. Design Data were collected from five cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. Forward-masked psychophysical tuning curves were obtained for channels with the highest, lowest, and median tripolar (σ=1 or 0.9) thresholds. The probe channel and level were fixed and presented with either the monopolar (σ=0) or a more focused partial tripolar (σ ≥ 0.55) configuration. The masker channel and level were varied while the configuration was fixed to σ = 0.5. A standard, three-interval, two-alternative forced choice procedure was used for thresholds and masked levels. Results Single-channel threshold and variability in threshold across channels systematically increased as the compensating current, σ, increased and the presumed electrical field became more focused. Across subjects, channels with the highest single-channel thresholds, when measured with a narrow, partial tripolar stimulus, had significantly broader psychophysical tuning curves than the lowest threshold channels. In two subjects, the tips of the tuning curves were shifted away from the probe channel. Tuning curves were also wider for the monopolar probes than with partial tripolar probes, for both the highest and lowest threshold channels. Conclusions These results suggest that single-channel thresholds measured with a restricted stimulus can be used to identify cochlear implant channels with poor spatial selectivity. Channels having wide or tip-shifted tuning characteristics would likely not deliver the appropriate spectral information to the intended auditory neurons, leading to suboptimal perception. As a clinical tool, quick identification of impaired channels could lead to patient-specific mapping strategies and result in improved speech and music perception. PMID:20090533

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pak, S.; Sites, J.R.

    A Kaufman-type broad beam ion source, used for sputtering and etching purposes, has been operated with Ar, Kr,O/sub 2/ and N/sub 2/ gas inputs over a wide range of beam energies (200-1200 eV) and gas flow rates (1-10 sccm). The maximum ion beam current density for each gas saturates at about 2.5 mA/sq. cm. as gas flow is increased. The discharge threshold voltage necessary to produce a beam and the beam efficiency (beam current/molecular current), however, varied considerably. Kr had the lowest threshold and highest efficiency, Ar next, then N/sub 2/ and O/sub 2/. The ion beam current varied onlymore » weakly with beam energy for low gas flow rates, but showed a factor of two increase when the gas flow was higher.« less

  6. Threshold Determination for Local Instantaneous Sea Surface Height Derivation with Icebridge Data in Beaufort Sea

    NASA Astrophysics Data System (ADS)

    Zhu, C.; Zhang, S.; Xiao, F.; Li, J.; Yuan, L.; Zhang, Y.; Zhu, T.

    2018-05-01

    The NASA Operation IceBridge (OIB) mission is the largest program in the Earth's polar remote sensing science observation project currently, initiated in 2009, which collects airborne remote sensing measurements to bridge the gap between NASA's ICESat and the upcoming ICESat-2 mission. This paper develop an improved method that optimizing the selection method of Digital Mapping System (DMS) image and using the optimal threshold obtained by experiments in Beaufort Sea to calculate the local instantaneous sea surface height in this area. The optimal threshold determined by comparing manual selection with the lowest (Airborne Topographic Mapper) ATM L1B elevation threshold of 2 %, 1 %, 0.5 %, 0.2 %, 0.1 % and 0.05 % in A, B, C sections, the mean of mean difference are 0.166 m, 0.124 m, 0.083 m, 0.018 m, 0.002 m and -0.034 m. Our study shows the lowest L1B data of 0.1 % is the optimal threshold. The optimal threshold and manual selections are also used to calculate the instantaneous sea surface height over images with leads, we find that improved methods has closer agreement with those from L1B manual selections. For these images without leads, the local instantaneous sea surface height estimated by using the linear equations between distance and sea surface height calculated over images with leads.

  7. Image intensifier gain uniformity improvements in sealed tubes by selective scrubbing

    DOEpatents

    Thomas, S.W.

    1995-04-18

    The gain uniformity of sealed microchannel plate image intensifiers (MCPIs) is improved by selectively scrubbing the high gain sections with a controlled bright light source. Using the premise that ions returning to the cathode from the microchannel plate (MCP) damage the cathode and reduce its sensitivity, a HeNe laser beam light source is raster scanned across the cathode of a microchannel plate image intensifier (MCPI) tube. Cathode current is monitored and when it exceeds a preset threshold, the sweep rate is decreased 1000 times, giving 1000 times the exposure to cathode areas with sensitivity greater than the threshold. The threshold is set at the cathode current corresponding to the lowest sensitivity in the active cathode area so that sensitivity of the entire cathode is reduced to this level. This process reduces tube gain by between 10% and 30% in the high gain areas while gain reduction in low gain areas is negligible. 4 figs.

  8. Image intensifier gain uniformity improvements in sealed tubes by selective scrubbing

    DOEpatents

    Thomas, Stanley W.

    1995-01-01

    The gain uniformity of sealed microchannel plate image intensifiers (MCPIs) is improved by selectively scrubbing the high gain sections with a controlled bright light source. Using the premise that ions returning to the cathode from the microchannel plate (MCP) damage the cathode and reduce its sensitivity, a HeNe laser beam light source is raster scanned across the cathode of a microchannel plate image intensifier (MCPI) tube. Cathode current is monitored and when it exceeds a preset threshold, the sweep rate is decreased 1000 times, giving 1000 times the exposure to cathode areas with sensitivity greater than the threshold. The threshold is set at the cathode current corresponding to the lowest sensitivity in the active cathode area so that sensitivity of the entire cathode is reduced to this level. This process reduces tube gain by between 10% and 30% in the high gain areas while gain reduction in low gain areas is negligible.

  9. Dual-lasing channel quantum cascade laser based on scattering-assisted injection design.

    PubMed

    Wen, Boyu; Xu, Chao; Wang, Siyi; Wang, Kaixi; Tam, Man Chun; Wasilewski, Zbig; Ban, Dayan

    2018-04-02

    A dual lasing channel Terahertz Quantum Cascade laser (THz QCL) based on GaAs/Al 0.17 Ga 0.83 As material system is demonstrated. The device shows the lowest reported threshold current density (550A/cm 2 at 50K) of GaAs/Al x Ga 1-x As material system based scattering-assisted (SA) structures and operates up to a maximum lasing temperature of 144K. Dual lasing channel operation is investigated theoretically and experimentally. The combination of low frequency emission, dual lasing channel operation, low lasing threshold current density and high temperature performance make such devices ideal candidates for low frequency applications, and initiates the design strategy for achieving high-temperature performance terahertz quantum cascade laser with wide frequency coverage at low frequency.

  10. Oscillation patterns are enhanced and firing threshold is lowered in medullary respiratory neuron discharges by threshold doses of a μ-opioid receptor agonist

    PubMed Central

    Mifflin, Steve W.

    2017-01-01

    μ-Opioid receptors are distributed widely in the brain stem respiratory network, and opioids with selectivity for μ-type receptors slow in vivo respiratory rhythm in lowest effective doses. Several studies have reported μ-opioid receptor effects on the three-phase rhythm of respiratory neurons, but there are until now no reports of opioid effects on oscillatory activity within respiratory discharges. In this study, effects of the μ-opioid receptor agonist fentanyl on spike train discharge properties of several different types of rhythm-modulating medullary respiratory neuron discharges were analyzed. Doses of fentanyl that were just sufficient for prolongation of discharges and slowing of the three-phase respiratory rhythm also produced pronounced enhancement of spike train properties. Oscillation and burst patterns detected by autocorrelation measurements were greatly enhanced, and interspike intervals were prolonged. Spike train properties under control conditions and after fentanyl were uniform within each experiment, but varied considerably between experiments, which might be related to variability in acid-base balance in the brain stem extracellular fluid. Discharge threshold was shifted to more negative levels of membrane potential. The effects on threshold are postulated to result from opioid-mediated disinhibition and postsynaptic enhancement of N-methyl-d- aspartate receptor current. Lowering of firing threshold, enhancement of spike train oscillations and bursts and prolongation of discharges by lowest effective doses of fentanyl could represent compensatory adjustments in the brain stem respiratory network to override opioid blunting of CO2/pH chemosensitivity. PMID:28202437

  11. Oscillation patterns are enhanced and firing threshold is lowered in medullary respiratory neuron discharges by threshold doses of a μ-opioid receptor agonist.

    PubMed

    Lalley, Peter M; Mifflin, Steve W

    2017-05-01

    μ-Opioid receptors are distributed widely in the brain stem respiratory network, and opioids with selectivity for μ-type receptors slow in vivo respiratory rhythm in lowest effective doses. Several studies have reported μ-opioid receptor effects on the three-phase rhythm of respiratory neurons, but there are until now no reports of opioid effects on oscillatory activity within respiratory discharges. In this study, effects of the μ-opioid receptor agonist fentanyl on spike train discharge properties of several different types of rhythm-modulating medullary respiratory neuron discharges were analyzed. Doses of fentanyl that were just sufficient for prolongation of discharges and slowing of the three-phase respiratory rhythm also produced pronounced enhancement of spike train properties. Oscillation and burst patterns detected by autocorrelation measurements were greatly enhanced, and interspike intervals were prolonged. Spike train properties under control conditions and after fentanyl were uniform within each experiment, but varied considerably between experiments, which might be related to variability in acid-base balance in the brain stem extracellular fluid. Discharge threshold was shifted to more negative levels of membrane potential. The effects on threshold are postulated to result from opioid-mediated disinhibition and postsynaptic enhancement of N -methyl-d- aspartate receptor current. Lowering of firing threshold, enhancement of spike train oscillations and bursts and prolongation of discharges by lowest effective doses of fentanyl could represent compensatory adjustments in the brain stem respiratory network to override opioid blunting of CO 2 /pH chemosensitivity. Copyright © 2017 the American Physiological Society.

  12. Opposite optimal current flow directions for induction of neuroplasticity and excitation threshold in the human motor cortex.

    PubMed

    Sommer, Martin; Norden, Christoph; Schmack, Lars; Rothkegel, Holger; Lang, Nicolas; Paulus, Walter

    2013-05-01

    Directional sensitivity is relevant for the excitability threshold of the human primary motor cortex, but its importance for externally induced plasticity is unknown. To study the influence of current direction on two paradigms inducing neuroplasticity by repetitive transcranial magnetic stimulation (rTMS). We studied short-lasting after-effects induced in the human primary motor cortex of 8 healthy subjects, using 5 Hz rTMS applied in six blocks of 200 pulses each, at 90% active motor threshold. We controlled for intensity, frequency, waveform and spinal effects. Only biphasic pulses with the effective component delivered in an anterioposterior direction (henceforth posteriorly directed) in the brain yielded an increase of motor-evoked potential (MEP) amplitudes outlasting rTMS. MEP latencies and F-wave amplitudes remained unchanged. Biphasic pulses directed posteroanterior (i.e. anteriorly) were ineffective, as were monophasic pulses from either direction. A 1 Hz study in a group of 12 healthy subjects confirmed facilitation after posteriorly directed biphasic pulses only. The anisotropy of the human primary motor cortex is relevant for induction of plasticity by subtreshold rTMS, with a current flow opposite to that providing lowest excitability thresholds. This is consistent with the idea of TMS primarily targeting cortical columns of the phylogenetically new M1 in the anterior bank of the central sulcus. For these, anteriorly directed currents are soma-depolarizing, therefore optimal for low thresholds, whereas posteriorly directed currents are soma-hyperpolarizing, likely dendrite-depolarizing and bested suited for induction of plasticity. Our findings should help focus and enhance rTMS effects in experimental and clinical settings. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Field emission from isolated individual vertically aligned carbon nanocones

    NASA Astrophysics Data System (ADS)

    Baylor, L. R.; Merkulov, V. I.; Ellis, E. D.; Guillorn, M. A.; Lowndes, D. H.; Melechko, A. V.; Simpson, M. L.; Whealton, J. H.

    2002-04-01

    Field emission from isolated individual vertically aligned carbon nanocones (VACNCs) has been measured using a small-diameter moveable probe. The probe was scanned parallel to the sample plane to locate the VACNCs, and perpendicular to the sample plane to measure the emission turn-on electric field of each VACNC. Individual VACNCs can be good field emitters. The emission threshold field depends on the geometric aspect ratio (height/tip radius) of the VACNC and is lowest when a sharp tip is present. VACNCs exposed to a reactive ion etch process demonstrate a lowered emission threshold field while maintaining a similar aspect ratio. Individual VACNCs can have low emission thresholds, carry high current densities, and have long emission lifetime. This makes them very promising for various field emission applications for which deterministic placement of the emitter with submicron accuracy is needed.

  14. Species sensitivity distribution evaluation for selenium in fish eggs: considerations for development of a Canadian tissue-based guideline.

    PubMed

    DeForest, David K; Gilron, Guy; Armstrong, Sarah A; Robertson, Erin L

    2012-01-01

    A freshwater Se guideline was developed for consideration based on concentrations in fish eggs or ovaries, with a focus on Canadian species, following the Canadian Council of Ministers of the Environment protocol for developing guideline values. When sufficient toxicity data are available, the protocol recommends deriving guidelines as the 5th percentile of the species sensitivity distribution (SSD). When toxicity data are limited, the protocol recommends a lowest value approach, where the lowest toxicity threshold is divided by a safety factor (e.g., 10). On the basis of a comprehensive review of the current literature and an assessment of the data therein, there are sufficient egg and ovary Se data available for freshwater fish to develop an SSD. For most fish species, Se EC10 values (10% effect concentrations) could be derived, but for some species, only no-observed-effect concentrations and/or lowest-observed-effect concentrations could be identified. The 5th percentile egg and ovary Se concentrations from the SSD were consistently 20 µg/g dry weight (dw) for the best-fitting distributions. In contrast, the lowest value approach using a safety factor of 10 would result in a Se egg and ovary guideline of 2 µg/g dw, which is unrealistically conservative, as this falls within the range of egg and ovary Se concentrations in laboratory control fish and fish collected from reference sites. An egg and ovary Se guideline of 20 µg/g dw should be considered a conservative, broadly applicable guideline, as no species mean toxicity thresholds lower than this value have been identified to date. When concentrations exceed this guideline, site-specific studies with local fish species, conducted using a risk-based approach, may result in higher egg and ovary Se toxicity thresholds. Copyright © 2011 SETAC.

  15. The mercedes-benz approach to γ-ray astronomy

    NASA Astrophysics Data System (ADS)

    Akerlof, Carl W.

    1988-02-01

    The sensitivity requirements for ground-based γ-ray astronomy are reviewed in the light of the most reliable estimates of stellar fluxes above 100 GeV. Current data strongly favor the construction of detectors with the lowest energy thresholds. Since improvements in angular resolution are limited by shower fluctuations, better methods of rejecting hadronic showers must be found to reliably observe the known astrophysical sources. Several possible methods for reducing this hadronic background are discussed.

  16. The threshold laws for electron-atom and positron-atom impact ionization

    NASA Technical Reports Server (NTRS)

    Temkin, A.

    1983-01-01

    The Coulomb-dipole theory is employed to derive a threshold law for the lowest energy needed for the separation of three particles from one another. The study focuses on an electron impinging on a neutral atom, and the dipole is formed between an inner electron and the nucleus. The analytical dependence of the transition matrix element on energy is reduced to lowest order to obtain the threshold law, with the inner electron providing a shield for the nucleus. Experimental results using the LAMPF accelerator to produce a high energy beam of H- ions, which are then exposed to an optical laser beam to detach the negative H- ion, are discussed. The threshold level is found to be confined to the region defined by the upper bound of the inverse square of the Coulomb-dipole region. Difficulties in exact experimental confirmation of the threshold are considered.

  17. Comparisons between detection threshold and loudness perception for individual cochlear implant channels

    PubMed Central

    Bierer, Julie Arenberg; Nye, Amberly D

    2014-01-01

    Objective The objective of the present study, performed in cochlear implant listeners, was to examine how the level of current required to detect single-channel electrical pulse trains relates to loudness perception on the same channel. The working hypothesis was that channels with relatively high thresholds, when measured with a focused current pattern, interface poorly to the auditory nerve. For such channels a smaller dynamic range between perceptual threshold and the most comfortable loudness would result, in part, from a greater sensitivity to changes in electrical field spread compared to low-threshold channels. The narrower range of comfortable listening levels may have important implications for speech perception. Design Data were collected from eight, adult cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp.). The partial tripolar (pTP) electrode configuration, consisting of one intracochlear active electrode, two flanking electrodes carrying a fraction (σ) of the return current, and an extracochlear ground, was used for stimulation. Single-channel detection thresholds and most comfortable listening levels were acquired using the most focused pTP configuration possible (σ ≥ 0.8) to identify three channels for further testing – those with the highest, median, and lowest thresholds – for each subject. Threshold, equal-loudness contours (at 50% of the monopolar dynamic range), and loudness growth functions were measured for each of these three test channels using various partial tripolar fractions. Results For all test channels, thresholds increased as the electrode configuration became more focused. The rate of increase with the focusing parameter σ was greatest for the high-threshold channel compared to the median- and low-threshold channels. The 50% equal-loudness contours exhibited similar rates of increase in level across test channels and subjects. Additionally, test channels with the highest thresholds had the narrowest dynamic ranges (for σ ≥ 0.5) and steepest growth of loudness functions for all electrode configurations. Conclusions Together with previous studies using focused stimulation, the results suggest that auditory responses to electrical stimuli at both threshold and suprathreshold current levels are not uniform across the electrode array of individual cochlear implant listeners. Specifically, the steeper growth of loudness and thus smaller dynamic ranges observed for high-threshold channels are consistent with a degraded electrode-neuron interface, which could stem from lower numbers of functioning auditory neurons or a relatively large distance between the neurons and electrodes. These findings may have potential implications for how stimulation levels are set during the clinical mapping procedure, particularly for speech-processing strategies that use focused electrical fields. PMID:25036146

  18. Simulation and optimization of deep violet InGaN double quantum well laser

    NASA Astrophysics Data System (ADS)

    Alahyarizadeh, Gh.; Ghazai, A. J.; Rahmani, R.; Mahmodi, H.; Hassan, Z.

    2012-03-01

    The performance characteristics of a deep violet InGaN double quantum well laser diode (LD) such as threshold current ( Ith), external differential quantum efficiency (DQE) and output power have been investigated using the Integrated System Engineering Technical Computer Aided Design (ISE-TCAD) software. As well as its operating parameters such as internal quantum efficiency ( ηi), internal loss ( αi) and transparency threshold current density ( J0) have been studied. Since, we are interested to investigate the mentioned characteristics and parameters independent of well and barrier thickness, therefore to reach a desired output wavelength, the indium mole fraction of wells and barriers has been varied consequently. The indium mole fractions of well and barrier layers have been considered 0.08 and 0.0, respectively. Some important parameters such as Al mole fraction of the electronic blocking layer (EBL) and cavity length which affect performance characteristics were also investigated. The optimum values of the Al mole fraction and cavity length in this study are 0.15 and 400 μm, respectively. The lowest threshold current, the highest DQE and output power which obtained at the emission wavelength of 391.5 nm are 43.199 mA, 44.99% and 10.334 mW, respectively.

  19. Assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection.

    PubMed

    Durante, Alessandra Spada; Wieselberg, Margarita Bernal; Roque, Nayara; Carvalho, Sheila; Pucci, Beatriz; Gudayol, Nicolly; de Almeida, Kátia

    The use of hearing aids by individuals with hearing loss brings a better quality of life. Access to and benefit from these devices may be compromised in patients who present difficulties or limitations in traditional behavioral audiological evaluation, such as newborns and small children, individuals with auditory neuropathy spectrum, autism, and intellectual deficits, and in adults and the elderly with dementia. These populations (or individuals) are unable to undergo a behavioral assessment, and generate a growing demand for objective methods to assess hearing. Cortical auditory evoked potentials have been used for decades to estimate hearing thresholds. Current technological advances have lead to the development of equipment that allows their clinical use, with features that enable greater accuracy, sensitivity, and specificity, and the possibility of automated detection, analysis, and recording of cortical responses. To determine and correlate behavioral auditory thresholds with cortical auditory thresholds obtained from an automated response analysis technique. The study included 52 adults, divided into two groups: 21 adults with moderate to severe hearing loss (study group); and 31 adults with normal hearing (control group). An automated system of detection, analysis, and recording of cortical responses (HEARLab ® ) was used to record the behavioral and cortical thresholds. The subjects remained awake in an acoustically treated environment. Altogether, 150 tone bursts at 500, 1000, 2000, and 4000Hz were presented through insert earphones in descending-ascending intensity. The lowest level at which the subject detected the sound stimulus was defined as the behavioral (hearing) threshold (BT). The lowest level at which a cortical response was observed was defined as the cortical electrophysiological threshold. These two responses were correlated using linear regression. The cortical electrophysiological threshold was, on average, 7.8dB higher than the behavioral for the group with hearing loss and, on average, 14.5dB higher for the group without hearing loss for all studied frequencies. The cortical electrophysiological thresholds obtained with the use of an automated response detection system were highly correlated with behavioral thresholds in the group of individuals with hearing loss. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  20. Threshold dose for behavioral discrimination of cigarette nicotine content in menthol vs. non-menthol smokers.

    PubMed

    Perkins, Kenneth A; Kunkle, Nicole; Karelitz, Joshua L

    2017-04-01

    The lowest threshold content (or "dose") of nicotine discriminated in cigarettes may differ due to menthol preference. Menthol and non-menthol Spectrum research cigarettes differing in nicotine content were used to determine discrimination thresholds. Dependent smokers preferring menthol (n = 40) or non-menthol (n = 21) brands were tested on ability to discriminate cigarettes (matched for their menthol preference) with nicotine contents of 16-17, 11-12, 5, 2, and 1 mg/g, one per session, from an "ultra-low" cigarette with 0.4 mg/g. Controlled exposure to each cigarette was four puffs/trial, and the number of sessions was determined by the lowest nicotine content they could discriminate on >80% of trials (i.e., ≥5 of 6). We also assessed subjective perceptions and behavioral choice between cigarettes to relate them to discrimination responses. Controlling for Fagerstrom Test of Nicotine Dependence score, discrimination thresholds were more likely to be at higher nicotine content cigarettes for menthol vs. non-menthol smokers (p < .005), with medians of 16 vs. 11 mg/g, respectively. Compared to the ultra-low, threshold and subthreshold (next lowest) cigarettes differed on most perceptions and puff choice, but menthol preference did not alter these associations. Notably, threshold cigarettes did, but subthreshold did not, increase choice over the ultra-low. Threshold for discriminating nicotine via smoking may be generally higher for menthol vs. non-menthol smokers. More research is needed to identify why menthol smoking is related to higher nicotine thresholds and to verify that cigarettes unable to be discriminated do not support reinforcement.

  1. Frequently Asked Questions on Potassium Iodide (KI)

    MedlinePlus

    ... recommendation is to treat them at the lowest threshold (with respect to predicted radioactive dose to the ... old should be treated at a slightly higher threshold. Finally, anyone over 40 years old should be ...

  2. Dispersion equation for electrostatic ion cyclotron instability under the effect of ionization in a dusty plasma

    NASA Astrophysics Data System (ADS)

    Singh, Sukhmander

    2018-05-01

    In the present paper we derive the plasma dispersion equation under the effect of ionization rate in a dust plasma to investigate the electrostatic ion cyclotron instability, where dust charge fluctuation is absent. It has one of the lowest threshold drift velocities among all the current-driven instabilities in isothermal plasma. The Electrostatic ion cyclotron instability in a dusty plasma containing electrons, light ions, and massive negatively charged dust grains which can be investigated both experimentally and theoretically.

  3. Emission wavelength of AlGaAs-GaAs multiple quantum well lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blood, P.; Fletcher, E.D.; Hulyer, P.J.

    1986-04-28

    We have recorded spontaneous emission spectra from multiple quantum well lasers grown by molecular beam epitaxy with 25-A-wide GaAs wells by opening a window in the top contact stripe. These spectra have a low-energy tail and consequently the gain spectra derived from them show that laser emission occurs at a lower photon energy than the lowest energy confined particle transition. The observed laser wavelength and threshold current are consistent with the position of the peak in the gain spectrum.

  4. The Topo-trigger: a new concept of stereo trigger system for imaging atmospheric Cherenkov telescopes

    NASA Astrophysics Data System (ADS)

    López-Coto, R.; Mazin, D.; Paoletti, R.; Blanch Bigas, O.; Cortina, J.

    2016-04-01

    Imaging atmospheric Cherenkov telescopes (IACTs) such as the Major Atmospheric Gamma-ray Imaging Cherenkov (MAGIC) telescopes endeavor to reach the lowest possible energy threshold. In doing so the trigger system is a key element. Reducing the trigger threshold is hampered by the rapid increase of accidental triggers generated by ambient light (the so-called Night Sky Background NSB). In this paper we present a topological trigger, dubbed Topo-trigger, which rejects events on the basis of their relative orientation in the telescope cameras. We have simulated and tested the trigger selection algorithm in the MAGIC telescopes. The algorithm was tested using MonteCarlo simulations and shows a rejection of 85% of the accidental stereo triggers while preserving 99% of the gamma rays. A full implementation of this trigger system would achieve an increase in collection area between 10 and 20% at the energy threshold. The analysis energy threshold of the instrument is expected to decrease by ~ 8%. The selection algorithm was tested on real MAGIC data taken with the current trigger configuration and no γ-like events were found to be lost.

  5. A piecewise regression approach for determining biologically relevant hydraulic thresholds for the protection of fishes at river infrastructure.

    PubMed

    Boys, C A; Robinson, W; Miller, B; Pflugrath, B; Baumgartner, L J; Navarro, A; Brown, R; Deng, Z

    2016-05-01

    A piecewise regression approach was used to objectively quantify barotrauma injury thresholds in two physoclistous species, Murray cod Maccullochella peelii and silver perch Bidyanus bidyanus, following simulated infrastructure passage in a barometric chamber. The probability of injuries such as swimbladder rupture, exophthalmia and haemorrhage, and emphysema in various organs increased as the ratio between the lowest exposure pressure and the acclimation pressure (ratio of pressure change, R(NE:A) ) reduced. The relationship was typically non-linear and piecewise regression was able to quantify thresholds in R(NE:A) that once exceeded resulted in a substantial increase in barotrauma injury. Thresholds differed among injury types and between species but by applying a multispecies precautionary principle, the maintenance of exposure pressures at river infrastructure above 70% of acclimation pressure (R(NE:A) of 0·7) should protect downstream migrating juveniles of these two physoclistous species sufficiently. These findings have important implications for determining the risk posed by current infrastructures and informing the design and operation of new ones. © 2016 The Fisheries Society of the British Isles.

  6. Evolution of the optimum bidirectional (+/- biphasic) wave for defibrillation.

    PubMed

    Geddes, L A; Havel, W

    2000-01-01

    Introduction of the asymmetric bidirectional (+/- biphasic) current waveform has made it possible to achieve ventricular defibrillation with less energy and current than are needed with a unidirectional (monophasic) waveform. The symmetrical bidirectional (sinusoidal) waveform was used for the first human-heart defibrillation. Subsequent studies employed the underdamped and overdamped sine waves, then the trapezoidal (monophasic) wave. Studies were then undertaken to investigate the benefit of adding a second identical and inverted wave; little success rewarded these efforts until it was discovered that the second inverted wave needed to be much less in amplitude to lower the threshold for defibrillation. However, there is no physiologic theory that explains the mechanism of action of the bidirectional wave, nor does any theory predict the optimum amplitude and time dimensions for the second inverted wave. The authors analyze the research that shows that the threshold defibrillation energy is lowest when the charge in the second, inverted phase is slightly more than a third of that in the first phase. An ion-flux, spatial-K+ summation hypothesis is presented that shows the effect on myocardial cells of adding the second inverted current pulse.

  7. Teleportation of a general two-mode coherent-state superposition via attenuated quantum channels with ideal and/or threshold detectors

    NASA Astrophysics Data System (ADS)

    An, Nguyen Ba

    2009-04-01

    Three novel probabilistic yet conclusive schemes are proposed to teleport a general two-mode coherent-state superposition via attenuated quantum channels with ideal and/or threshold detectors. The calculated total success probability is highest (lowest) when only ideal (threshold) detectors are used.

  8. Surfing Silicon Nanofacets for Cold Cathode Electron Emission Sites.

    PubMed

    Basu, Tanmoy; Kumar, Mohit; Saini, Mahesh; Ghatak, Jay; Satpati, Biswarup; Som, Tapobrata

    2017-11-08

    Point sources exhibit low threshold electron emission due to local field enhancement at the tip. In the case of silicon, however, the realization of tip emitters has been hampered by unwanted oxidation, limiting the number of emission sites and the overall current. In contrast to this, here, we report the fascinating low threshold (∼0.67 V μm -1 ) cold cathode electron emission from silicon nanofacets (Si-NFs). The ensembles of nanofacets fabricated at different time scales, under low energy ion impacts, yield tunable field emission with a Fowler-Nordheim tunneling field in the range of 0.67-4.75 V μm -1 . The local probe surface microscopy-based tunneling current mapping in conjunction with Kelvin probe force microscopy measurements revealed that the valleys and a part of the sidewalls of the nanofacets contribute more to the field emission process. The observed lowest turn-on field is attributed to the absence of native oxide on the sidewalls of the smallest facets as well as their lowest work function. In addition, first-principle density functional theory-based simulation revealed a crystal orientation-dependent work function of Si, which corroborates well with our experimental observations. The present study demonstrates a novel way to address the origin of the cold cathode electron emission sites from Si-NFs fabricated at room temperature. In principle, the present methodology can be extended to probe the cold cathode electron emission sites from any nanostructured material.

  9. Determining electrically evoked compound action potential thresholds: a comparison of computer versus human analysis methods.

    PubMed

    Glassman, E Katelyn; Hughes, Michelle L

    2013-01-01

    Current cochlear implants (CIs) have telemetry capabilities for measuring the electrically evoked compound action potential (ECAP). Neural Response Telemetry (Cochlear) and Neural Response Imaging (Advanced Bionics [AB]) can measure ECAP responses across a range of stimulus levels to obtain an amplitude growth function. Software-specific algorithms automatically mark the leading negative peak, N1, and the following positive peak/plateau, P2, and apply linear regression to estimate ECAP threshold. Alternatively, clinicians may apply expert judgments to modify the peak markers placed by the software algorithms, or use visual detection to identify the lowest level yielding a measurable ECAP response. The goals of this study were to: (1) assess the variability between human and computer decisions for (a) marking N1 and P2 and (b) determining linear-regression threshold (LRT) and visual-detection threshold (VDT); and (2) compare LRT and VDT methods within and across human- and computer-decision methods. ECAP amplitude-growth functions were measured for three electrodes in each of 20 ears (10 Cochlear Nucleus® 24RE/CI512, and 10 AB CII/90K). LRT, defined as the current level yielding an ECAP with zero amplitude, was calculated for both computer- (C-LRT) and human-picked peaks (H-LRT). VDT, defined as the lowest level resulting in a measurable ECAP response, was also calculated for both computer- (C-VDT) and human-picked peaks (H-VDT). Because Neural Response Imaging assigns peak markers to all waveforms but does not include waveforms with amplitudes less than 20 μV in its regression calculation, C-VDT for AB subjects was defined as the lowest current level yielding an amplitude of 20 μV or more. Overall, there were significant correlations between human and computer decisions for peak-marker placement, LRT, and VDT for both manufacturers (r = 0.78-1.00, p < 0.001). For Cochlear devices, LRT and VDT correlated equally well for both computer- and human-picked peaks (r = 0.98-0.99, p < 0.001), which likely reflects the well-defined Neural Response Telemetry algorithm and the lower noise floor in the 24RE and CI512 devices. For AB devices, correlations between LRT and VDT for both peak-picker methods were weaker than for Cochlear devices (r = 0.69-0.85, p < 0.001), which likely reflect the higher noise floor of the system. Disagreement between computer and human decisions regarding the presence of an ECAP response occurred for 5 % of traces for Cochlear devices and 2.1 % of traces for AB devices. Results indicate that human and computer peak-picking methods can be used with similar accuracy for both Cochlear and AB devices. Either C-VDT or C-LRT can be used with equal confidence for Cochlear 24RE and CI512 recipients because both methods are strongly correlated with human decisions. However, for AB devices, greater variability exists between different threshold-determination methods. This finding should be considered in the context of using ECAP measures to assist with programming CIs.

  10. Current induced domain wall motion in antiferromagnetically coupled (Co70Fe30/Pd) multilayer nanowires

    NASA Astrophysics Data System (ADS)

    Meng, Zhaoliang; He, Shikun; Huang, Lisen; Qiu, Jinjun; Zhou, Tiejun; Panagopoulos, Christos; Han, Guchang; Teo, Kie-Leong

    2016-10-01

    We investigate the current induced domain wall (DW) motion in the ultrathin CoFe/Pd multilayer based synthetically antiferromagnetic (SAF) structure nanowires by anomalous Hall effect measurement. The threshold current density (Jth) for the DW displacement decreases and the DW velocity (v) increases accordingly with the exchange coupling Jex between the top and bottom ferromagnetic CoFe/Pd multilayers. The lowest Jth = 9.3 × 1010 A/m2 and a maximum v = 150 m/s with J = 1.5 × 1012 A/m2 are achieved due to the exchange coupling torque (ECT) generated in the SAF structure. The strength of ECT is dependent on both of Jex and the strong spin-orbit torque mainly generated by Ta layer.

  11. Silicon Nanowire Field Effect Transistor Sensors with Minimal Sensor to Sensor Variations and Enhanced Sensing Characteristics.

    PubMed

    Zafar, Sufi; D'Emic, Christopher; Jagtiani, Ashish; Kratschmer, Ernst; Miao, Xin; Zhu, Yu; Mo, Renee; Sosa, Norma; Hamann, Hendrik F; Shahidi, Ghavam; Riel, Heike

    2018-06-22

    Silicon nanowire field effect transistor (FET) sensors have demonstrated their ability for rapid and label free detection of proteins, nucleotide sequences, and viruses at ultralow concentrations with the potential to be a transformative diagnostic technology. Their nanoscale size gives them their unique ultralow detection ability but also makes their fabrication challenging with large sensor to sensor variations, thus limiting their commercial applications. In this work, a combined approach of nanofabrication, device simulation, materials and electrical characterization is applied towards identifying and improving fabrication steps that induce sensor to sensor variations. An enhanced complementary metal-oxide-semiconductor (CMOS) compatible process for fabricating silicon nanowire FET sensors is demonstrated. Nanowire (30 nm width) FETs with aqueous solution as gates are shown to have the Nernst limit sub-threshold swing SS = 60 mV/decade with ~1.7% variations, whereas literature values for SS are ≥ 80 mV/decade with larger (>10 times) variations. Also, their threshold voltage variations are significantly (~3 times) reduced, compared to literature values. Furthermore, these improved FETs have significantly reduced drain current hysteresis (~0.6 mV) and enhanced on-current to off-current ratios (~10 6 ). These improvements resulted in nanowire FET sensors with lowest (~3%) reported sensor to sensor variations, compared to literature studies. Also, these improved nanowire sensors have the highest reported sensitivity and enhanced signal to noise ratio with the lowest reported defect density of 1x10 18 eV -1 cm -3 in comparison to literature data. In summary, this work brings the nanowire sensor technology a step closer to commercial products for early diagnosis and monitoring of diseases.

  12. Transport temperatures observed during the commercial transportation of animals.

    PubMed

    Fiore, Gianluca; Hofherr, Johann; Natale, Fabrizio; Mainetti, Sergio; Ruotolo, Espedito

    2012-01-01

    Current temperature standards and those proposed by the European Food Safety Authority (EFSA) were compared with the actual practices of commercial transport in the European Union. Temperature and humidity records recorded for a year on 21 vehicles over 905 journeys were analysed. Differences in temperature and humidity recorded by sensors at four different positions in the vehicles exceeded 10°C between the highest and lowest temperatures in nearly 7% of cases. The number and position of temperature sensors are important to ensure the correct representation of temperature conditions in the different parts of a vehicle. For all journeys and all animal categories, a relatively high percentage of beyond threshold temperatures can be observed in relation to the temperature limits of 30°C and 5°C. Most recorded temperature values lie within the accepted tolerance of ±5°C stipulated in European Community Regulation (EC) 1/2005. The temperature thresholds proposed by EFSA would result in a higher percentage of non-compliant conditions which are more pronounced at the lower threshold, compared to the thresholds laid down in Regulation (EC) 1/2005. With respect to the different animal categories, the non-compliant temperature occurrences were more frequent in pigs and sheep, in particular with regard to the thresholds proposed by EFSA.

  13. The sensitivity of normal brain and intracranially implanted VX2 tumour to interstitial photodynamic therapy.

    PubMed Central

    Lilge, L.; Olivo, M. C.; Schatz, S. W.; MaGuire, J. A.; Patterson, M. S.; Wilson, B. C.

    1996-01-01

    The applicability and limitations of a photodynamic threshold model, used to describe quantitatively the in vivo response of tissues to photodynamic therapy, are currently being investigated in a variety of normal and malignant tumour tissues. The model states that tissue necrosis occurs when the number of photons absorbed by the photosensitiser per unit tissue volume exceeds a threshold. New Zealand White rabbits were sensitised with porphyrin-based photosensitisers. Normal brain or intracranially implanted VX2 tumours were illuminated via an optical fibre placed into the tissue at craniotomy. The light fluence distribution in the tissue was measured by multiple interstitial optical fibre detectors. The tissue concentration of the photosensitiser was determined post mortem by absorption spectroscopy. The derived photodynamic threshold values for normal brain are significantly lower than for VX2 tumour for all photosensitisers examined. Neuronal damage is evident beyond the zone of frank necrosis. For Photofrin the threshold decreases with time delay between photosensitiser administration and light treatment. No significant difference in threshold is found between Photofrin and haematoporphyrin derivative. The threshold in normal brain (grey matter) is lowest for sensitisation by 5 delta-aminolaevulinic acid. The results confirm the very high sensitivity of normal brain to porphyrin photodynamic therapy and show the importance of in situ light fluence monitoring during photodynamic irradiation. Images Figure 1 Figure 4 Figure 5 Figure 6 Figure 7 PMID:8562339

  14. Phosphorus and carrier density of heavily n-type doped germanium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takinai, K.; Wada, K.

    2016-05-14

    The threshold current density of n-type, tensile-strained Ge lasers strongly depends on the electron density. Although optical net gain analyses indicate that the optimum electron density should be on the order of 1 × 10{sup 20} cm{sup −3} to get the lowest threshold, it is not a simple task to increase the electron density beyond the mid range of 10{sup 19} cm{sup −3}. The present paper analyzes the phenomenon where electron density is not proportional to phosphorus donor density, i.e., “saturation” phenomenon, by applying the so-called amphoteric defect model. The analyses indicate that the saturation phenomenon can be well explained by the charge compensationmore » between the phosphorus donors (P{sup +}) and doubly negative charged Ge vacancies (V{sup 2−}).« less

  15. A piecewise regression approach for determining biologically relevant hydraulic thresholds for the protection of fish at river infrastructure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boys, Craig A.; Robinson, Wayne; Miller, Brett

    2016-05-13

    Barotrauma injury can occur when fish are exposed to rapid decompression during downstream passage through river infrastructure. A piecewise regression approach was used to objectively quantify barotrauma injury thresholds in two physoclistous species (Murray cod Maccullochella peelii and silver perch Bidyanus bidyanus) following simulated infrastructure passage in barometric chambers. The probability of injuries such as swim bladder rupture; exophthalmia; and haemorrhage and emphysema in various organs increased as the ratio between the lowest exposure pressure and the acclimation pressure (ratio of pressure change RPCE/A) fell. The relationship was typically non-linear and piecewise regression was able to quantify thresholds in RPCE/Amore » that once exceeded resulted in a substantial increase in barotrauma injury. Thresholds differed among injury types and between species but by applying a multi-species precautionary principle, the maintenance of exposure pressures at river infrastructure above 70% of acclimation pressure (RPCE/A of 0.7) should sufficiently protect downstream migrating juveniles of these two physoclistous species. These findings have important implications for determining the risk posed by current infrastructures and informing the design and operation of new ones.« less

  16. Olfactory Threshold of Chlorine in Oxygen.

    DTIC Science & Technology

    1977-09-01

    The odor threshold of chlorine in oxygen was determined. Measurements were conducted in an altitude chamber, which provided an odor-free and noise...free background. Human male volunteers, with no previous olfactory acuity testing experience, served as panelists. Threshold values were affected by...time intervals between trials and by age differences. The mean threshold value for 11 subjects was 0.08 ppm obtained by positive responses to the lowest detectable level of chlorine in oxygen, 50% of the time. (Author)

  17. Rare Disease Terminology and Definitions-A Systematic Global Review: Report of the ISPOR Rare Disease Special Interest Group.

    PubMed

    Richter, Trevor; Nestler-Parr, Sandra; Babela, Robert; Khan, Zeba M; Tesoro, Theresa; Molsen, Elizabeth; Hughes, Dyfrig A

    2015-09-01

    At present, there is no universal definition of rare disease. To provide an overview of rare disease definitions currently used globally. We systematically searched for definitions related to rare disease from organizations in 32 international jurisdictions. Descriptive statistics of definitions were generated and prevalence thresholds were calculated. We identified 296 definitions from 1109 organizations. The terms "rare disease(s)" and "orphan drug(s)" were used most frequently (38% and 27% of the definitions, respectively). Qualitative descriptors such as "life-threatening" were used infrequently. A prevalence threshold was specified in at least one definition in 88% of the jurisdictions. The average prevalence threshold across organizations within individual jurisdictions ranged from 5 to 76 cases/100,000 people. Most jurisdictions (66%) had an average prevalence threshold between 40 and 50 cases/100,000 people, with a global average of 40 cases/100,000 people. Prevalence thresholds used by different organizations within individual jurisdictions varied substantially. Across jurisdictions, umbrella patient organizations had the highest (most liberal) average prevalence threshold (47 cases/100,000 people), whereas private payers had the lowest threshold (18 cases/100,000 people). Despite variation in the terminology and prevalence thresholds used to define rare diseases among different jurisdictions and organizations, the terms "rare disease" and "orphan drug" are used most widely and the average prevalence threshold is between 40 and 50 cases/100,000 people. These findings highlight the existing diversity among definitions of rare diseases, but suggest that any attempts to harmonize rare disease definitions should focus on standardizing objective criteria such as prevalence thresholds and avoid qualitative descriptors. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  18. The locking and unlocking thresholds for tearing modes in a cylindrical tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Wenlong; Zhu, Ping, E-mail: pzhu@ustc.edu.cn; Department of Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706

    2016-03-15

    The locking and unlocking thresholds for tearing modes are in general different. In this work, the physics origin for this difference is illustrated from theory analysis, and a numerical procedure is developed to find both locking and unlocking thresholds. In particular, a new scaling law for the unlocking threshold that is valid in both weak and strong rotation regimes has been derived from the lowest amplitude of the RMP (resonant magnetic perturbation) allowed for the locked-mode solution. Above the unlocking threshold, the criterion for the phase-flip instability is extended to identify the entire locked-mode states. Two different regimes of themore » RMP amplitude in terms of the accessibility of the locked-mode states have been found. In the first regime, the locked-mode state may or may not be accessible depending on the initial conditions of an evolving island. In the second regime, the locked-mode state can always be reached regardless of the initial conditions of the tearing mode. The lowest RMP amplitude for the second regime is determined to be the mode-locking threshold. The different characteristics of the two regimes above the unlocking threshold reveal the underlying physics for the gap between the locking and unlocking thresholds and provide an explanation for the closely related and widely observed hysteresis phenomena in island evolution during the sweeping process of the RMP amplitude up and down across that threshold gap.« less

  19. Walsh Preprocessor.

    DTIC Science & Technology

    1980-08-01

    tile se(q uenw threshold does not utilize thle D)C level inlforiat ion and the time thlresliolditig adaptively adjusts for DC lvel . 𔃻This characteristic...lowest 256/8 = 32 elements. The above observation can be mathematically proven to also relate the fact that the lowest (NT/W) elements can, at worst case

  20. Activation of boron and recrystallization in Ge preamorphization implant structure of ultra shallow junctions by microwave annealing

    NASA Astrophysics Data System (ADS)

    Tsai, Ming Han; Wu, Chi-Ting; Lee, Wen-His

    2014-04-01

    In this study, high-current and low-energy (400 eV) ion implantation and low-temperature microwave annealing were employed to achieve ultra shallow junctions. To use the characteristic of microwave annealing more effectively, two-step microwave annealing was also employed. In the first step annealing, a high-power (2400 W; ˜500 °C) microwave was used to achieve solid-state epitaxial regrowth (SPER) and enhance microwave absorption. In the second step of annealing, unlike in conventional thermal annealing, which requires a higher energy to activate the dopant, a 600 W (˜250 °C) microwave was used to achieve low sheet resistance. The device subjected to two-step microwave annealing at 2400 W for 300 s + 600 W for 600 s has the lowest Vth. It also has the lowest subthreshold swing (SS), which means that it has the highest cap ability to control sub threshold current. In these three devices, the largest Ion/Ioff ratio is 2.203 × 106, and the smallest Ion/Ioff ratio is 2.024 × 106.

  1. Ultralow-threshold Yb(3+):SiO(2) glass laser fabricated by the solgel process.

    PubMed

    Ostby, Eric P; Yang, Lan; Vahala, Kerry J

    2007-09-15

    A Yb-doped silica microcavity laser on a silicon chip is fabricated from a solgel thin film. The high-Q micro-toroid cavity, which has a finesse of 10,000, is evanescently coupled to an optical fiber taper. We report a threshold of 1.8 microW absorbed power that is, to the best of our knowledge, the lowest published threshold to date for any Yb-doped laser. The effect of Yb(3+) concentration on laser threshold is experimentally quantified.

  2. High-performance 1.3-μm laser diode by LP-MOVPE

    NASA Astrophysics Data System (ADS)

    Li, TongNing; Ji, Jin-yan; Yan, Xin-min; Liu, Tao; Ning, Zhou; Liu, Jiang; Liu, Zi-li; Huang, Ge-fan

    1996-09-01

    The progress in 1.3 micrometers wavelength InGaAsP/InP lasers for optic fiber communication and subscriber loop applications is reviewed. By using LP-MOVPE/LPE epitaxy techniques, the performance of commercial optical devices is considerably improved. The bandwidth of the 1.3 micrometers uncooled MQW-LD module could be high to 1.6GHz, threshold current Ith < 15mA, maximum fiber output power Pf >= 20mW while uniformity, reproducible, high yield are achieved. Further by growing active layer with compressive strained structure the lowest threshold current Ith equals 3.8mA was achieved with high reflection coating and the temperature performance of the SL-MQW-LD has been greatly improved, the change of slop efficiency at 25 degrees C and 85 degrees C is less than 1 dB. Using the holographic technique a high power 1.31 micrometers InGaAsP/InP multiquantum well distributed feedback laser has also been developed. The fiber output power of butterfly packaged module with optic isolator Pf > 10mW, threshold current Ith < 18mA, slop efficiency Es > 22 percent and side mode suppression ratio SMSR > 40dB. The composite triple beat CTB < -66dBc and the composite second order CSO < -56dBc by test frequencies equals 55.25 to approximately 289.25MHz with 40 NCTA channels, the carrier to noise ration CNR > 50 dB and the relative intensity noise RIN < -160dB/Hz.

  3. Measurement of the lowest dosage of phenobarbital that can produce drug discrimination in rats

    PubMed Central

    Overton, Donald A.; Stanwood, Gregg D.; Patel, Bhavesh N.; Pragada, Sreenivasa R.; Gordon, M. Kathleen

    2009-01-01

    Rationale Accurate measurement of the threshold dosage of phenobarbital that can produce drug discrimination (DD) may improve our understanding of the mechanisms and properties of such discrimination. Objectives Compare three methods for determining the threshold dosage for phenobarbital (D) versus no drug (N) DD. Methods Rats learned a D versus N DD in 2-lever operant training chambers. A titration scheme was employed to increase or decrease dosage at the end of each 18-day block of sessions depending on whether the rat had achieved criterion accuracy during the sessions just completed. Three criterion rules were employed, all based on average percent drug lever responses during initial links of the last 6 D and 6 N sessions of a block. The criteria were: D%>66 and N%<33; D%>50 and N%<50; (D%-N%)>33. Two squads of rats were trained, one immediately after the other. Results All rats discriminated drug versus no drug. In most rats, dosage decreased to low levels and then oscillated near the minimum level required to maintain criterion performance. The lowest discriminated dosage significantly differed under the three criterion rules. The squad that was trained 2nd may have benefited by partially duplicating the lever choices of the previous squad. Conclusions The lowest discriminated dosage is influenced by the criterion of discriminative control that is employed, and is higher than the absolute threshold at which discrimination entirely disappears. Threshold estimations closer to absolute threshold can be obtained when criteria are employed that are permissive, and that allow rats to maintain lever preferences. PMID:19082992

  4. Characteristics of OMVPE grown GaAsBi QW lasers and impact of post-growth thermal annealing

    NASA Astrophysics Data System (ADS)

    Kim, Honghyuk; Guan, Yingxin; Babcock, Susan E.; Kuech, Thomas F.; Mawst, Luke J.

    2018-03-01

    Laser diodes employing a strain-compensated GaAs1-xBix/GaAs1-yPy single quantum well (SQW) active region were grown by organometallic vapor phase epitaxy (OMVPE). High resolution x-ray diffraction, room temperature photoluminescence, and real-time optical reflectance measurements during the OMVPE growth were used to find the optimum process window for the growth of the active region material. Systematic post-growth in situ thermal anneals of various lengths were carried out in order to investigate the impacts of thermal annealing on the laser device performance characteristics. While the lowest threshold current density was achieved after the thermal annealing for 30 min at 630 °C, a gradual decrease in the external differential quantum efficiency was observed as the annealing time increases. It was observed that the temperature sensitivities of the threshold current density increase while those of lasing wavelength and slope efficiency remain nearly constant with increasing annealing time. Z-contrast scanning transmission electron microscopic) analysis revealed inhomogeneous Bi distribution within the QW active region.

  5. Effect of QW thickness and numbers on performance characteristics of deep violet InGaN MQW lasers

    NASA Astrophysics Data System (ADS)

    Alahyarizadeh, Gh.; Amirhoseiny, M.; Hassan, Z.

    2015-03-01

    The performance characteristics of deep violet indium gallium nitride (InGaN) multiquantum well (MQW) laser diodes (LDs) with an emission wavelength of around 390 nm have been investigated using the integrated system engineering technical computer aided design (ISE-TCAD) software. A comparative study on the effect of quantum well (QW) thickness and number on electrical and optical performance of deep violet In0.082Ga0.918N/GaN MQW LDs have been carried out. The simulation results showed that the highest slope efficiency and external differential quantum efficiency (DQE), as well as the lowest threshold current are obtained when the number of wells is two. The different QW thickness values of 2.2, 2.5, 2.8, 3 and 3.2 nm were compared and the best results were achieved for 2.5 nm QW thickness. The radiative recombination rate decreases with increasing QW thickness because of decreasing electron and hole carrier densities in wells. By increasing QW thickness, output power decreases and threshold current increases.

  6. Optimization of the highly strained InGaAs/GaAs quantum well lasers grown by MOVPE

    NASA Astrophysics Data System (ADS)

    Su, Y. K.; Chen, W. C.; Wan, C. T.; Yu, H. C.; Chuang, R. W.; Tsai, M. C.; Cheng, K. Y.; Hu, C.; Tsau, Seth

    2008-07-01

    In this article, we study the highly compressive-strained InGaAs/GaAs quantum wells and the broad-area lasers grown by MOVPE. Several epitaxial parameters were optimized, including the growth temperature, pressure and group V to group III (V/III) ratio. Grown with the optimized epitaxial parameters, the highly strained In 0.39Ga 0.61As/GaAs lasers could be continuously operated at 1.22 μm and their threshold current density Jth was 140 A/cm 2. To the best of our knowledge, the demonstrated InGaAs QW laser has the lowest threshold current per quantum well (Jth/QW) of 46.7 A/cm 2. The fitted characteristic temperature ( T0) was 146.2 K, indicating the good electron confinement ability. Furthermore, by lowering the growth temperature down to 475 °C and the TBAs/III ratio to 5, the emission wavelength of the In 0.42Ga 0.58As/GaAs quantum wells was as long as 1245 nm and FWHM was 43 meV.

  7. Low amplified spontaneous emission threshold and suppression of electroluminescence efficiency roll-off in layers doped with ter(9,9'-spirobifluorene)

    NASA Astrophysics Data System (ADS)

    Inoue, Munetomo; Matsushima, Toshinori; Adachi, Chihaya

    2016-03-01

    We demonstrate that ter(9,9'-spirobifluorene) (TSBF) doped in a host matrix layer of 4,4'-bis(carbazol-9-yl)biphenyl (CBP) shows a low amplified spontaneous emission (ASE) threshold (Eth = 1.0 μJ cm-2) and suppressed electroluminescence efficiency roll-off at high current densities (no roll-off up to 100 mA cm-2). One origin of the low ASE threshold is that the TSBF-doped CBP layer possesses a very large radiative decay constant (kr = 1.1 × 109 s-1). Singlet-triplet annihilation is almost suppressed in the TSBF-doped CBP layer, which can be ascribed to the small overlap between the emission and triplet absorption of TSBF. Also, the small energy level difference between TSBF and CBP minimizes carrier trapping in TSBF, leading to the suppression of singlet-polaron annihilation. TSBF showed one of the lowest Eth and the most suppressed efficiency roll-off among organic laser dyes investigated in this study and, therefore, is believed to be a promising candidate to realize electrically pumped organic semiconductor laser diodes in the future.

  8. Stability of Heavy Tetraquarks

    NASA Astrophysics Data System (ADS)

    Valcarce, A.; Vijande, J.; Richard, J.-M.; Garcilazo, H.

    2018-03-01

    We discuss the stability of tetraquark systems with two different masses. After some reminders about the stability of very asymmetric QQ{\\bar{q}} {\\bar{q}} tetraquarks, we demonstrate that in the all-heavy limit q → Q, the system becomes unstable for standard color-additive models. We also analyze the consequences of symmetry breaking for Qq{\\bar{Q}}{\\bar{q}} configurations: we find a kind of metastability between the lowest threshold Q{\\bar{Q}} + q{\\bar{q}} and the highest one, Q{\\bar{q}}+{\\bar{Q}} q, and we calculate the width of the resonance. Our results are consistent with the experimental observation of narrow hadrons lying well above their lowest decay threshold.

  9. Bone conduction reception: head sensitivity mapping.

    PubMed

    McBride, Maranda; Letowski, Tomasz; Tran, Phuong

    2008-05-01

    This study sought to identify skull locations that are highly sensitive to bone conduction (BC) auditory signal reception and could be used in the design of military radio communication headsets. In Experiment 1, pure tone signals were transmitted via BC to 11 skull locations of 14 volunteers seated in a quiet environment. In Experiment 2, the same signals were transmitted via BC to nine skull locations of 12 volunteers seated in an environment with 60 decibels of white background noise. Hearing threshold levels for each signal per location were measured. In the quiet condition, the condyle had the lowest mean threshold for all signals followed by the jaw angle, mastoid and vertex. In the white noise condition, the condyle also had the lowest mean threshold followed by the mastoid, vertex and temple. Overall results of both experiments were very similar and implicated the condyle as the most effective location.

  10. Paradigm shift in lead design.

    PubMed

    Irnich, W

    1999-09-01

    During the past 30 years there has been a tremendous development in electrode technology from bulky (90 mm2) to pin-sized (1.0 mm2) electrodes. Simultaneously, impedance has increased from 110 Ohms to >1 kOhms, which has been termed a "paradigm shift" in lead design. If current is responsible for stimulation, why is its impedance a key factor in saving energy? Further, what mechanism is behind this development based on experimental findings and what conclusion can be drawn from it to optimize electrode size? If it is assumed that there is always a layer of nonexcitable tissue between the electrode surface and excitable myocardium and that the electric field (potential gradient) produced by the electrode at this boundary is reaching threshold level, then a formula can be derived for the voltage threshold that completely describes the electrophysiology and electrophysics of a hemispherical electrode. Assuming that the mean chronic threshold for porous steroid-eluting electrodes is 0.6 V with 0.5-ms pulse duration, thickness of nonexcitable tissue can be estimated to be 1.5 mm. Taking into account this measure and the relationship between chronaxie and electrode area, voltage threshold, impedance, and energy as a function of surface area can be calculated. The lowest voltage for 0.5-ms pulse duration is reached with r(o) = 0.5 d, yielding a surface area of 4 mm2 and a voltage threshold of 0.62 V, an impedance of 1 kOhms, and an energy level of 197 nJ. It can be deduced from our findings that a further reduction of surface areas below 1.6 mm2 will not diminish energy threshold substantially, if pulse duration remains at 0.5 ms. Lowest energy is reached with t = chronaxie, yielding an energy level <100 nJ with surface areas < or =1.5 mm2. It is striking to see how well the theoretically derived results correspond to the experimental findings. It is also surprising that the hemispheric model so accurately approximates experimental results with differently shaped electrodes that it can be concluded that electrode shape seems to play a minor role in electrode efficiency. Further energy reduction can only be achieved by reducing the pulse duration to chronaxie. A real paradigm shift will occur only if the fundamentals of electrostimulation in combination with electrophysics are accepted by the pacing community.

  11. Threshold dose for discrimination of nicotine via cigarette smoking.

    PubMed

    Perkins, Kenneth A; Kunkle, Nicole; Karelitz, Joshua L; Michael, Valerie C; Donny, Eric C

    2016-06-01

    The lowest nicotine threshold "dose" in cigarettes discriminated from a cigarette containing virtually no nicotine may help inform the minimum dose maintaining dependence. Spectrum research cigarettes (from NIDA) differing in nicotine content were used to evaluate a procedure to determine discrimination thresholds. Dependent smokers (n = 18; 13 M, 5 F) were tested on ability to discriminate cigarettes with nicotine contents of 11, 5, 2.4, and 1.3 mg/g, one per session, from the "ultralow" cigarette with 0.4 mg/g, after having discriminated 16 mg/g from 0.4 mg/g (all had 9-10 mg "tar"). Exposure to each was limited to 4 puffs/trial. All subjects were abstinent from smoking overnight prior to each session, and the number of sessions was determined by the participant's success in discrimination behavior on >80 % of trials. Subjective perceptions and behavioral choice between cigarettes were also assessed and related to discrimination behavior. The median threshold was 11 mg/g, but the range was 2.4 to 16 mg/g, suggesting wide variability in discrimination threshold. Compared to the ultralow, puff choice was greater for the subject's threshold dose but only marginal for the subthreshold (next lowest nicotine) cigarette. Threshold and subthreshold also differed on subjective perceptions but not withdrawal relief. Under these testing conditions, threshold content for discriminating nicotine via cigarettes may be 11 mg/g or greater for most smokers, but some can discriminate nicotine contents one-half or one-quarter this amount. Further study with other procedures and cigarette exposure amounts may identify systematic differences in nicotine discrimination thresholds.

  12. Drug Policy in the Czech Republic.

    PubMed

    Skoupá, Jana

    2017-09-01

    The legal background of the current pharmaceutical pricing and reimbursement (P&R) setting in the Czech Republic is based on Act 48/1997. Since 2008, the P&R process has been coordinated by the State Institute for Drug Control, which is the main stakeholder in the decision-making process; marketing authorization holders and insurance funds (IFs) also participate. To present a general overview of the current Czech health care system and its P&R principles. The study used publicly available sources concerning health care, mainly acts related to public health care and public health care insurance, public notices related to P&R setting, and statistical data. Regulation covers P&R. The official price represents the highest exfactory price, which cannot be exceeded. It is calculated as the mean of the three lowest prices in the European Union reference basket. Reimbursement is based on the lowest price per daily dose across the whole European Union. For reimbursement, products can be clustered into jumbo groups (mutually interchangeable), stated by law. In each group, reimbursement is set at the lowest price of any substance within the group. For highly innovative drugs a temporary reimbursement can be granted for a period of 3 years. During the administrative proceeding, efficacy, safety, cost-effectiveness, and budget impact are assessed. The cost-effectiveness principles are aligned with the guidelines of the National Institute for Health and Clinical Care Excellence, preferring cost-utility analyses. The willingness-to-pay threshold has been implicitly set at 3 times the gross domestic product per capita. Products exceeding this threshold are subject to further risk-sharing negotiations. Budget impact is becoming increasingly important mainly for IFs. The IFs have recently introduced their own methodology, which allows only products with a budget impact in the range of CZK16 to CZK48 million (CZK = Czech koruna; ∼€600,000 to €1.8 million) to enter the system. Products exceeding this budget impact have to negotiate risk-sharing schemes, mainly further discounts and/or budget caps. The Czech pricing and reimbursement system is rather complex, taking into account clinical evidence, cost-effectiveness and budget impact. The strict regulations are a result of financial scarcity. Copyright © 2017. Published by Elsevier Inc.

  13. Thresholds of Toxicological Concern - Setting a threshold for testing below which there is little concern.

    PubMed

    Hartung, Thomas

    2017-01-01

    Low dose, low risk; very low dose, no real risk. Setting a pragmatic threshold below which concerns become negligible is the purpose of thresholds of toxicological concern (TTC). The idea is that such threshold values do not need to be established for each and every chemical based on experimental data, but that by analyzing the distribution of lowest or no-effect doses of many chemicals, a TTC can be defined - typically using the 5th percentile of this distribution and lowering it by an uncertainty factor of, e.g., 100. In doing so, TTC aims to compare exposure information (dose) with a threshold below which any hazard manifestation is very unlikely to occur. The history and current developments of this concept are reviewed and the application of TTC for different regulated products and their hazards is discussed. TTC lends itself as a pragmatic filter to deprioritize testing needs whenever real-life exposures are much lower than levels where hazard manifestation would be expected, a situation that is called "negligible exposure" in the REACH legislation, though the TTC concept has not been fully incorporated in its implementation (yet). Other areas and regulations - especially in the food sector and for pharmaceutical impurities - are more proactive. Large, curated databases on toxic effects of chemicals provide us with the opportunity to set TTC for many hazards and substance classes and thus offer a precautionary second tier for risk assessments if hazard cannot be excluded. This allows focusing testing efforts better on relevant exposures to chemicals.

  14. Threshold-selecting strategy for best possible ground state detection with genetic algorithms

    NASA Astrophysics Data System (ADS)

    Lässig, Jörg; Hoffmann, Karl Heinz

    2009-04-01

    Genetic algorithms are a standard heuristic to find states of low energy in complex state spaces as given by physical systems such as spin glasses but also in combinatorial optimization. The paper considers the problem of selecting individuals in the current population in genetic algorithms for crossover. Many schemes have been considered in literature as possible crossover selection strategies. We show for a large class of quality measures that the best possible probability distribution for selecting individuals in each generation of the algorithm execution is a rectangular distribution over the individuals sorted by their energy values. This means uniform probabilities have to be assigned to a group of the individuals with lowest energy in the population but probabilities equal to zero to individuals which are corresponding to energy values higher than a fixed cutoff, which is equal to a certain rank in the vector sorted by the energy of the states in the current population. The considered strategy is dubbed threshold selecting. The proof applies basic arguments of Markov chains and linear optimization and makes only a few assumptions on the underlying principles and hence applies to a large class of algorithms.

  15. Searching for beauty-fully bound tetraquarks using lattice nonrelativistic QCD

    NASA Astrophysics Data System (ADS)

    Hughes, Ciaran; Eichten, Estia; Davies, Christine T. H.

    2018-03-01

    Motivated by multiple phenomenological considerations, we perform the first search for the existence of a b ¯b ¯b b tetraquark bound state with a mass below the lowest noninteracting bottomonium-pair threshold using the first-principles lattice nonrelativistic QCD methodology. We use a full S -wave color/spin basis for the b ¯b ¯b b operators in the three 0++, 1+- and 2++ channels. We employ four gluon field ensembles at multiple lattice spacing values ranging from a =0.06 - 0.12 fm , all of which include u , d , s and c quarks in the sea, and one ensemble which has physical light-quark masses. Additionally, we perform novel exploratory work with the objective of highlighting any signal of a near threshold tetraquark, if it existed, by adding an auxiliary potential into the QCD interactions. With our results we find no evidence of a QCD bound tetraquark below the lowest noninteracting thresholds in the channels studied.

  16. Searching for beauty-fully bound tetraquarks using lattice nonrelativistic QCD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, Ciaran; Eichten, Estia; Davies, Christine T. H.

    Motivated by multiple phenomenological considerations, we perform the first search for the existence of amore » $$\\bar{bb}bb$$ tetraquark bound state with a mass below the lowest noninteracting bottomonium-pair threshold using the first-principles lattice nonrelativistic QCD methodology. Here, we use a full S-wave color/spin basis for the $$\\bar{bb}bb$$ operators in the three 0 ++, 1 +- and 2 ++ channels. We employ four gluon field ensembles at multiple lattice spacing values ranging from a=0.06–0.12 fm, all of which include u, d, s and c quarks in the sea, and one ensemble which has physical light-quark masses. Additionally, we perform novel exploratory work with the objective of highlighting any signal of a near threshold tetraquark, if it existed, by adding an auxiliary potential into the QCD interactions. With our results we find no evidence of a QCD bound tetraquark below the lowest noninteracting thresholds in the channels studied.« less

  17. Searching for beauty-fully bound tetraquarks using lattice nonrelativistic QCD

    DOE PAGES

    Hughes, Ciaran; Eichten, Estia; Davies, Christine T. H.

    2018-03-14

    Motivated by multiple phenomenological considerations, we perform the first search for the existence of amore » $$\\bar{bb}bb$$ tetraquark bound state with a mass below the lowest noninteracting bottomonium-pair threshold using the first-principles lattice nonrelativistic QCD methodology. Here, we use a full S-wave color/spin basis for the $$\\bar{bb}bb$$ operators in the three 0 ++, 1 +- and 2 ++ channels. We employ four gluon field ensembles at multiple lattice spacing values ranging from a=0.06–0.12 fm, all of which include u, d, s and c quarks in the sea, and one ensemble which has physical light-quark masses. Additionally, we perform novel exploratory work with the objective of highlighting any signal of a near threshold tetraquark, if it existed, by adding an auxiliary potential into the QCD interactions. With our results we find no evidence of a QCD bound tetraquark below the lowest noninteracting thresholds in the channels studied.« less

  18. Preliminary test of cigarette nicotine discrimination threshold in non-dependent versus dependent smokers.

    PubMed

    Perkins, Kenneth A; Kunkle, Nicole; Karelitz, Joshua L; Perkins, K A; Kunkle, N; Karelitz, J L

    2017-06-01

    Despite its potential for understanding tobacco dependence, behavioral discrimination of nicotine via smoking has not been formally examined as a function of nicotine dependence level. Spectrum research cigarettes were used to compare non-dependent with dependent smokers on the lowest content of nicotine they could discriminate (i.e., "threshold"). Dependent (n=21; 16M, 5F) or non-dependent (n=7; 4M, 3F) smokers were tested on ability to discriminate between cigarettes with nicotine contents of 17, 11, 5, 2, and 1mg/g, one per session, from an "ultra-low" cigarette with 0.4mg/g (all had 9-10mg "tar"). All abstained from smoking overnight prior to sessions, and number of sessions was determined by the lowest nicotine content they could reliably discriminate from the ultra-low on >80% of trials (i.e., ≥5 of 6). Subjective perceptions and cigarette choice behavior were also assessed and related to discrimination behavior. Discrimination thresholds (and most perceptions) did not differ between dependent and non-dependent smokers, with median thresholds of 11mg/g for both subgroups. Yet, "liking" and puff choice for threshold cigarettes were greater in dependent but not non-dependent smokers, while cigarettes with nicotine contents below threshold did not support "liking" or choice in both groups. In sum, this preliminary study suggests threshold for discriminating nicotine via smoking may not vary by dependence level, and further study is needed to confirm that cigarettes unable to be discriminated are also not reinforcing. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Effects on Vocal Fold Collision and Phonation Threshold Pressure of Resonance Tube Phonation with Tube End in Water

    ERIC Educational Resources Information Center

    Enflo, Laura; Sundberg, Johan; Romedahl, Camilla; McAllister, Anita

    2013-01-01

    Purpose: Resonance tube phonation in water (RTPW) or in air is a voice therapy method successfully used for treatment of several voice pathologies. Its effect on the voice has not been thoroughly studied. This investigation analyzes the effects of RTPW on collision and phonation threshold pressures (CTP and PTP), the lowest subglottal pressure…

  20. Re-visiting Trichuris trichiura intensity thresholds based on anemia during pregnancy.

    PubMed

    Gyorkos, Theresa W; Gilbert, Nicolas L; Larocque, Renée; Casapía, Martín; Montresor, Antonio

    2012-01-01

    The intensity categories, or thresholds, currently used for Trichuris trichiura (ie. epg intensities of 1-999 (light); 1,000-9,999 epg (moderate), and ≥ 10,000 epg (heavy)) were developed in the 1980s, when there were little epidemiological data available on dose-response relationships. This study was undertaken to determine a threshold for T. trichiura-associated anemia in pregnant women and to describe the implications of this threshold in terms of the need for primary prevention and chemotherapeutic interventions. In Iquitos, Peru, 935 pregnant women were tested for T. trichiura infection in their second trimester of pregnancy; were given daily iron supplements throughout their pregnancy; and had their blood hemoglobin levels measured in their third trimester of pregnancy. Women in the highest two T. trichiura intensity quintiles (601-1632 epg and ≥ 1633 epg) had significantly lower mean hemoglobin concentrations than the lowest quintile (0-24 epg). They also had a statistically significantly higher risk of anemia, with adjusted odds ratios of 1.67 (95% CI: 1.02, 2.62) and 1.73 (95% CI: 1.09, 2.74), respectively. This analysis provides support for categorizing a T. trichiura infection ≥ 1,000 epg as 'moderate', as currently defined by the World Health Organization. Because this 'moderate' level of T. trichiura infection was found to be a significant risk factor for anemia in pregnant women, the intensity of Trichuris infection deemed to cause or aggravate anemia should no longer be restricted to the 'heavy' intensity category. It should now include both 'heavy' and 'moderate' intensities of Trichuris infection. Evidence-based deworming strategies targeting pregnant women or populations where anemia is of concern should be updated accordingly.

  1. Re-Visiting Trichuris trichiura Intensity Thresholds Based on Anemia during Pregnancy

    PubMed Central

    Gyorkos, Theresa W.; Gilbert, Nicolas L.; Larocque, Renée; Casapía, Martín; Montresor, Antonio

    2012-01-01

    Background The intensity categories, or thresholds, currently used for Trichuris trichiura (ie. epg intensities of 1–999 (light); 1,000–9,999 epg (moderate), and ≥10,000 epg (heavy)) were developed in the 1980s, when there were little epidemiological data available on dose-response relationships. This study was undertaken to determine a threshold for T. trichiura-associated anemia in pregnant women and to describe the implications of this threshold in terms of the need for primary prevention and chemotherapeutic interventions. Methodology/Principal Findings In Iquitos, Peru, 935 pregnant women were tested for T. trichiura infection in their second trimester of pregnancy; were given daily iron supplements throughout their pregnancy; and had their blood hemoglobin levels measured in their third trimester of pregnancy. Women in the highest two T. trichiura intensity quintiles (601–1632 epg and ≥1633 epg) had significantly lower mean hemoglobin concentrations than the lowest quintile (0–24 epg). They also had a statistically significantly higher risk of anemia, with adjusted odds ratios of 1.67 (95% CI: 1.02, 2.62) and 1.73 (95% CI: 1.09, 2.74), respectively. Conclusions/Significance This analysis provides support for categorizing a T. trichiura infection ≥1,000 epg as ‘moderate’, as currently defined by the World Health Organization. Because this ‘moderate’ level of T. trichiura infection was found to be a significant risk factor for anemia in pregnant women, the intensity of Trichuris infection deemed to cause or aggravate anemia should no longer be restricted to the ‘heavy’ intensity category. It should now include both ‘heavy’ and ‘moderate’ intensities of Trichuris infection. Evidence-based deworming strategies targeting pregnant women or populations where anemia is of concern should be updated accordingly. PMID:23029572

  2. The Neural Substrate for Binaural Masking Level Differences in the Auditory Cortex

    PubMed Central

    Gilbert, Heather J.; Krumbholz, Katrin; Palmer, Alan R.

    2015-01-01

    The binaural masking level difference (BMLD) is a phenomenon whereby a signal that is identical at each ear (S0), masked by a noise that is identical at each ear (N0), can be made 12–15 dB more detectable by inverting the waveform of either the tone or noise at one ear (Sπ, Nπ). Single-cell responses to BMLD stimuli were measured in the primary auditory cortex of urethane-anesthetized guinea pigs. Firing rate was measured as a function of signal level of a 500 Hz pure tone masked by low-passed white noise. Responses were similar to those reported in the inferior colliculus. At low signal levels, the response was dominated by the masker. At higher signal levels, firing rate either increased or decreased. Detection thresholds for each neuron were determined using signal detection theory. Few neurons yielded measurable detection thresholds for all stimulus conditions, with a wide range in thresholds. However, across the entire population, the lowest thresholds were consistent with human psychophysical BMLDs. As in the inferior colliculus, the shape of the firing-rate versus signal-level functions depended on the neurons' selectivity for interaural time difference. Our results suggest that, in cortex, BMLD signals are detected from increases or decreases in the firing rate, consistent with predictions of cross-correlation models of binaural processing and that the psychophysical detection threshold is based on the lowest neural thresholds across the population. PMID:25568115

  3. Long-term ambient concentrations of total suspended particulates and oxidants as related to incidence of chronic disease in California Seventh-Day Adventists.

    PubMed

    Abbey, D E; Mills, P K; Petersen, F F; Beeson, W L

    1991-08-01

    Cancer incidence and mortality in a cohort of 6000 nonsmoking California Seventh-Day Adventists were monitored for a 6-year period, and relationships with long-term cumulative ambient air pollution were observed. Total suspended particulates (TSP) and ozone were measured in terms of numbers of hours in excess of several threshold levels corresponding to national standards as well as mean concentration. For all malignant neoplasms among females, risk increased with increasing exceedance frequencies of all thresholds of TSP except the lowest one, and those increased risks were highly statistically significant. For respiratory cancers, increased risk was associated with only one threshold of ozone, and this result was of borderline significance. Respiratory disease symptoms were assessed in 1977 and again in 1987 using the National Heart, Lung and Blood Institute respiratory symptoms questionnaire on a subcohort of 3914 individuals. Multivariate analyses which adjusted for past and passive smoking and occupational exposures indicated statistically significantly (p less than 0.05) elevated relative risks ranging up to 1.7 for incidence of asthma, definite symptoms of airway obstructive disease, and chronic bronchitis with TSP in excess of all thresholds except the lowest one but not for any thresholds of ozone. A trend association (p = 0.056) was noted between the threshold of 10 pphm ozone and incidence of asthma. These results are presented within the context of standards setting for these constituents of air pollution.

  4. Long-term ambient concentrations of total suspended particulates and oxidants as related to incidence of chronic disease in California Seventh-Day Adventists.

    PubMed Central

    Abbey, D E; Mills, P K; Petersen, F F; Beeson, W L

    1991-01-01

    Cancer incidence and mortality in a cohort of 6000 nonsmoking California Seventh-Day Adventists were monitored for a 6-year period, and relationships with long-term cumulative ambient air pollution were observed. Total suspended particulates (TSP) and ozone were measured in terms of numbers of hours in excess of several threshold levels corresponding to national standards as well as mean concentration. For all malignant neoplasms among females, risk increased with increasing exceedance frequencies of all thresholds of TSP except the lowest one, and those increased risks were highly statistically significant. For respiratory cancers, increased risk was associated with only one threshold of ozone, and this result was of borderline significance. Respiratory disease symptoms were assessed in 1977 and again in 1987 using the National Heart, Lung and Blood Institute respiratory symptoms questionnaire on a subcohort of 3914 individuals. Multivariate analyses which adjusted for past and passive smoking and occupational exposures indicated statistically significantly (p less than 0.05) elevated relative risks ranging up to 1.7 for incidence of asthma, definite symptoms of airway obstructive disease, and chronic bronchitis with TSP in excess of all thresholds except the lowest one but not for any thresholds of ozone. A trend association (p = 0.056) was noted between the threshold of 10 pphm ozone and incidence of asthma. These results are presented within the context of standards setting for these constituents of air pollution. PMID:1954938

  5. Threshold Ionization and Spin-Orbit Coupling of Cerium Monoxide

    NASA Astrophysics Data System (ADS)

    Cao, Wenjin; Zhang, Yuchen; Wu, Lu; Yang, Dong-Sheng

    2017-06-01

    Cerium oxides are widely used in heterogeneous catalysis due to their ability to switch between different oxidation states. We report here the mass-analyzed threshold ionization (MATI) spectroscopy of cerium monoxide (CeO) produced by laser ablating a Ce rod in a molecular beam source. The MATI spectrum in the range of 40000-45000 \\wn exhibits several band systems with similar vibrational progressions. The strongest band is at 43015 (5) \\wn, which can be assigned as the adiabatic ionization energy of the neutral species. The spectrum also shows Ce-O stretching frequencies of 817 and 890 \\wn in the neutral and ion states, respectively. By comparing with spin-orbit coupled multireference quasi-degenerate perturbation theory (SO-MCQDPT) calculations, the observed band systems are assigned to transitions from various low-energy spin-orbit levels of the neutral oxide to the two lowest spin-orbit levels of the corresponding ion. The current work will also be compared with previous experimental and computational studies on the neutral species.

  6. Microstimulation of primary afferent neurons in the L7 dorsal root ganglia using multielectrode arrays in anesthetized cats: thresholds and recruitment properties

    NASA Astrophysics Data System (ADS)

    Gaunt, R. A.; Hokanson, J. A.; Weber, D. J.

    2009-10-01

    Current research in motor neural prosthetics has focused primarily on issues related to the extraction of motor command signals from the brain (e.g. brain-machine interfaces) to direct the motion of prosthetic limbs. Patients using these types of systems could benefit from a somatosensory neural interface that conveys natural tactile and kinesthetic sensations for the prosthesis. Electrical microstimulation within the dorsal root ganglia (DRG) has been proposed as one method to accomplish this, yet little is known about the recruitment properties of electrical microstimulation in activating nerve fibers in this structure. Current-controlled microstimulation pulses in the range of 1-15 µA (200 µs, leading cathodic pulse) were delivered to the L7 DRG in four anesthetized cats using penetrating microelectrode arrays. Evoked responses and their corresponding conduction velocities (CVs) were measured in the sciatic nerve with a 5-pole nerve cuff electrode arranged as two adjacent tripoles. It was found that in 76% of the 69 electrodes tested, the stimulus threshold was less than or equal to 3 µA, with the lowest recorded threshold being 1.1 µA. The CVs of afferents recruited at threshold had a bimodal distribution with peaks at 70 m s-1 and 85 m s-1. In 53% of cases, the CV of the response at threshold was slower (i.e. smaller diameter fiber) than the CVs of responses observed at increasing stimulation amplitudes. In summary, we found that microstimulation applied through penetrating microelectrodes in the DRG provides selective recruitment of afferent fibers from a range of sensory modalities (as identified by CVs) at very low stimulation intensities. We conclude that the DRG may serve as an attractive location from which to introduce surrogate somatosensory feedback into the nervous system.

  7. Gram-scale cryogenic calorimeters for rare-event searches

    NASA Astrophysics Data System (ADS)

    Strauss, R.; Rothe, J.; Angloher, G.; Bento, A.; Gütlein, A.; Hauff, D.; Kluck, H.; Mancuso, M.; Oberauer, L.; Petricca, F.; Pröbst, F.; Schieck, J.; Schönert, S.; Seidel, W.; Stodolsky, L.

    2017-07-01

    The energy threshold of a cryogenic calorimeter can be lowered by reducing its size. This is of importance since the resulting increase in signal rate enables new approaches in rare-event searches, including the detection of MeV mass dark matter and coherent scattering of reactor or solar neutrinos. A scaling law for energy threshold vs detector size is given. We analyze the possibility of lowering the threshold of a gram-scale cryogenic calorimeter to the few eV regime. A prototype 0.5 g Al2 O3 device achieved an energy threshold of Eth=(19.7 ±0.9 ) eV , the lowest value reported for a macroscopic calorimeter.

  8. Corona-vacuum failure mechanism test facilities

    NASA Technical Reports Server (NTRS)

    Lalli, V. R.; Mueller, L. A.; Koutnik, E. A.

    1975-01-01

    A nondestructive corona-vacuum test facility for testing high-voltage power system components has been developed using commercially available hardware. The facility simulates operating temperature and vacuum while monitoring coronal discharges with residual gases. Corona threshold voltages obtained from statorette tests with various gas-solid dielectric systems and comparison with calculated data support the following conclusions: (1) air gives the highest corona threshold voltage and helium the lowest, with argon and helium-xenon mixtures intermediate; (2) corona threshold voltage increases with gas pressure; (3) corona threshold voltage for an armature winding can be accurately calculated by using Paschen curves for a uniform field; and (4) Paschen curves for argon can be used to calculate the corona threshold voltage in He-Xe mixtures, for which Paschen curves are unavailable.-

  9. 47 CFR 15.323 - Specific requirements for devices operating in the 1920-1930 MHz sub-band.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... monitoring threshold must not be more than 30 dB above the thermal noise power for a bandwidth equivalent to... windows with the lowest power level below a monitoring threshold of 50 dB above the thermal noise power... of 20 °C. For equipment that is capable only of operating from a battery, the frequency stability...

  10. A Three-Threshold Learning Rule Approaches the Maximal Capacity of Recurrent Neural Networks

    PubMed Central

    Alemi, Alireza; Baldassi, Carlo; Brunel, Nicolas; Zecchina, Riccardo

    2015-01-01

    Understanding the theoretical foundations of how memories are encoded and retrieved in neural populations is a central challenge in neuroscience. A popular theoretical scenario for modeling memory function is the attractor neural network scenario, whose prototype is the Hopfield model. The model simplicity and the locality of the synaptic update rules come at the cost of a poor storage capacity, compared with the capacity achieved with perceptron learning algorithms. Here, by transforming the perceptron learning rule, we present an online learning rule for a recurrent neural network that achieves near-maximal storage capacity without an explicit supervisory error signal, relying only upon locally accessible information. The fully-connected network consists of excitatory binary neurons with plastic recurrent connections and non-plastic inhibitory feedback stabilizing the network dynamics; the memory patterns to be memorized are presented online as strong afferent currents, producing a bimodal distribution for the neuron synaptic inputs. Synapses corresponding to active inputs are modified as a function of the value of the local fields with respect to three thresholds. Above the highest threshold, and below the lowest threshold, no plasticity occurs. In between these two thresholds, potentiation/depression occurs when the local field is above/below an intermediate threshold. We simulated and analyzed a network of binary neurons implementing this rule and measured its storage capacity for different sizes of the basins of attraction. The storage capacity obtained through numerical simulations is shown to be close to the value predicted by analytical calculations. We also measured the dependence of capacity on the strength of external inputs. Finally, we quantified the statistics of the resulting synaptic connectivity matrix, and found that both the fraction of zero weight synapses and the degree of symmetry of the weight matrix increase with the number of stored patterns. PMID:26291608

  11. A Three-Threshold Learning Rule Approaches the Maximal Capacity of Recurrent Neural Networks.

    PubMed

    Alemi, Alireza; Baldassi, Carlo; Brunel, Nicolas; Zecchina, Riccardo

    2015-08-01

    Understanding the theoretical foundations of how memories are encoded and retrieved in neural populations is a central challenge in neuroscience. A popular theoretical scenario for modeling memory function is the attractor neural network scenario, whose prototype is the Hopfield model. The model simplicity and the locality of the synaptic update rules come at the cost of a poor storage capacity, compared with the capacity achieved with perceptron learning algorithms. Here, by transforming the perceptron learning rule, we present an online learning rule for a recurrent neural network that achieves near-maximal storage capacity without an explicit supervisory error signal, relying only upon locally accessible information. The fully-connected network consists of excitatory binary neurons with plastic recurrent connections and non-plastic inhibitory feedback stabilizing the network dynamics; the memory patterns to be memorized are presented online as strong afferent currents, producing a bimodal distribution for the neuron synaptic inputs. Synapses corresponding to active inputs are modified as a function of the value of the local fields with respect to three thresholds. Above the highest threshold, and below the lowest threshold, no plasticity occurs. In between these two thresholds, potentiation/depression occurs when the local field is above/below an intermediate threshold. We simulated and analyzed a network of binary neurons implementing this rule and measured its storage capacity for different sizes of the basins of attraction. The storage capacity obtained through numerical simulations is shown to be close to the value predicted by analytical calculations. We also measured the dependence of capacity on the strength of external inputs. Finally, we quantified the statistics of the resulting synaptic connectivity matrix, and found that both the fraction of zero weight synapses and the degree of symmetry of the weight matrix increase with the number of stored patterns.

  12. Proton threshold states in the Na22(p,γ)Mg23 reaction and astrophysical implications

    NASA Astrophysics Data System (ADS)

    Comisel, H.; Hategan, C.; Graw, G.; Wolter, H. H.

    2007-04-01

    Proton threshold states in Mg23 are important for the astrophysically relevant proton capture reaction Na22(p,γ)Mg23. In the indirect determination of the resonance strength of the lowest states, which were not accessible by direct methods, some of the spin-parity-assignments remained experimentally uncertain. We have investigated these states with shell model, Coulomb displacement, and Thomas-Ehrman shift calculations. From the comparison of calculated and observed properties, we relate the lowest relevant resonance state at Ex=7643 keV to an excited 3/2+ state in accordance with a recent experimental determination by Jenkins From this we deduce significantly improved values for the Na22(p,γ)Mg23 reaction rate at stellar temperatures below T9=0.1 K.

  13. Preliminary test of cigarette nicotine discrimination threshold in non-dependent versus dependent smokers

    PubMed Central

    Perkins, Kenneth A.; Kunkle, Nicole; Karelitz, Joshua L.

    2017-01-01

    Background Despite its potential for understanding tobacco dependence, behavioral discrimination of nicotine via smoking has not been formally examined as a function of nicotine dependence level. Methods Spectrum research cigarettes were used to compare non-dependent with dependent smokers on the lowest content of nicotine they could discriminate (i.e., “threshold”). Dependent (n=21; 16 M, 5 F) or non-dependent (n=7; 4 M, 3 F) smokers were tested on ability to discriminate between cigarettes with nicotine contents of 17, 11, 5, 2, and 1 mg/g, one per session, from an “ultra-low” cigarette with 0.4 mg/g (all had 9–10 mg “tar”). All abstained from smoking overnight prior to sessions, and number of sessions was determined by the lowest nicotine content they could reliably discriminate from the ultra-low on >80% of trials (i.e., ≥5 of 6). Subjective perceptions and cigarette choice behavior were also assessed and related to discrimination behavior. Results Discrimination thresholds (and most perceptions) did not differ between dependent and non-dependent smokers, with median thresholds of 11 mg/g for both subgroups. Yet, “liking” and puff choice for threshold cigarettes were greater in dependent but not non-dependent smokers, while cigarettes with nicotine contents below threshold did not support “liking” or choice in both groups. Conclusions In sum, this preliminary study suggests threshold for discriminating nicotine via smoking may not vary by dependence level, and further study is needed to confirm that cigarettes unable to be discriminated are also not reinforcing. PMID:28380366

  14. Fluorene- and benzofluorene-cored oligomers as low threshold and high gain amplifying media

    NASA Astrophysics Data System (ADS)

    Kazlauskas, Karolis; Kreiza, Gediminas; Bobrovas, Olegas; AdomÄ--nienÄ--, Ona; AdomÄ--nas, Povilas; Jankauskas, Vygintas; JuršÄ--nas, Saulius

    2015-07-01

    Deliberate control of intermolecular interactions in fluorene- and benzofluorene-cored oligomers was attempted via introduction of different-length alkyl moieties to attain high emission amplification and low amplified spontaneous emission (ASE) threshold at high oligomer concentrations. Containing fluorenyl peripheral groups decorated with different-length alkyl moieties, the oligomers were found to express weak concentration quenching of emission, yet excellent carrier drift mobilities (close to 10-2 cm2/V/s) in the amorphous films. Owing to the larger radiative decay rates (>1.0 × 109 s-1) and smaller concentration quenching, fluorene-cored oligomers exhibited down to one order of magnitude lower ASE thresholds at higher concentrations as compared to those of benzofluorene counterparts. The lowest threshold (300 W/cm2) obtained for the fluorene-cored oligomers at the concentration of 50 wt % in polymer matrix is among the lowest reported for solution-processed amorphous films in ambient conditions, what makes the oligomers promising for lasing application. Great potential in emission amplification was confirmed by high maximum net gain (77 cm-1) revealed for these compounds. Although the photostability of the oligomers was affected by photo-oxidation, it was found to be comparable to that of various organic lasing materials including some commercial laser dyes evaluated under similar excitation conditions.

  15. The optical breakdown threshold of air on a polished metal surface for radiation at lambda=10.6 microns

    NASA Astrophysics Data System (ADS)

    Arkhipov, Iu. V.; Belashkov, I. N.; Datskevich, N. P.; Egorov, V. N.; Iziumov, A. F.

    1986-01-01

    Threshold conditions for the formation of a plasma due to optical breakdown of air on the polished surfaces of Al, Co, Mi, and W samples have been investigated experimentally. The optical breakdown was initiated by pulsed radiation from two CO2 lasers having pulse powers 0.5 and 1.0 kJ, respectively. The thresholds for the formation of the plasma were determined for two exposure spots of o/14 sq mm and 46 sq cm, respectively. A metallographic study was carried out in order to identify the specific types of defects corresponding to the lowest optical breakdown thresholds. Before-and-after photographs of the metal surfaces are provided.

  16. Hypoxia tolerance of two centrarchid sunfishes and an introduced cichlid from karstic Everglades wetlands of southern Florida, U.S.A.

    USGS Publications Warehouse

    Schofield, P.J.; Loftus, W.F.; Brown, M.E.

    2007-01-01

    In this study, the hypoxia tolerance of three Everglades fishes, two native centrarchids (Lepomis gulosus and Lepomis marginatus) and a recently introduced cichlid (Hemichromis letourneuxi), were documented. Aquatic surface respiration (ASR) thresholds were lowest for H. letourneuxi, followed by L. gulosus, then L. marginatus. The ASR thresholds for L. marginatus were within ranges reported for small, freshwater tropical fishes, while those for L. gulosus were similar to swamp-adapted fishes. For H. letourneuxi, ASR thresholds were some of the lowest reported. All three species showed excellent tolerance of low dissolved oxygen levels when allowed access to the surface. When denied surface access, L. marginatus lost equilibrium at a higher oxygen tension than the other species. Overall, although all species easily tolerated hypoxia, H. letourneuxi appeared to be best equipped to deal with hypoxia, followed by L. gulosus, then L. marginatus. Hemichromis letourneuxi also exhibited more aggressive behaviours than the centrarchids. These results suggest that hypoxia is not likely to prevent H. letourneuxi from exploiting the seasonally inundated wetlands of south Florida while expanding its range there.

  17. Low amplified spontaneous emission threshold and suppression of electroluminescence efficiency roll-off in layers doped with ter(9,9′-spirobifluorene)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inoue, Munetomo; Center for Organic Photonics and Electronics Research, Kyushu University, 744 Motooka, Nishi, Fukuoka 819-0395; Matsushima, Toshinori

    2016-03-28

    We demonstrate that ter(9,9′-spirobifluorene) (TSBF) doped in a host matrix layer of 4,4′-bis(carbazol-9-yl)biphenyl (CBP) shows a low amplified spontaneous emission (ASE) threshold (E{sub th} = 1.0 μJ cm{sup −2}) and suppressed electroluminescence efficiency roll-off at high current densities (no roll-off up to 100 mA cm{sup −2}). One origin of the low ASE threshold is that the TSBF-doped CBP layer possesses a very large radiative decay constant (k{sub r} = 1.1 × 10{sup 9 }s{sup −1}). Singlet–triplet annihilation is almost suppressed in the TSBF-doped CBP layer, which can be ascribed to the small overlap between the emission and triplet absorption of TSBF. Also, the small energy level difference between TSBF and CBPmore » minimizes carrier trapping in TSBF, leading to the suppression of singlet–polaron annihilation. TSBF showed one of the lowest E{sub th} and the most suppressed efficiency roll-off among organic laser dyes investigated in this study and, therefore, is believed to be a promising candidate to realize electrically pumped organic semiconductor laser diodes in the future.« less

  18. Mode control in photonic crystal surface emitting lasers (PCSELs) through in-plane feedback (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Taylor, Richard J. E.; Li, Guangrui; Ivanov, Pavlo; Childs, David T. D.; Stevens, Ben J.; Babazadeh, Nasser; Ignatova, Olesya; Hogg, Richard A.

    2017-02-01

    All-semiconductor photonic crystal surface-emitting lasers (PCSELs) operating in CW mode at room temperature and coherently coupled arrays of these lasers are reviewed. These PCSELs are grown via MOVPE on GaAs substrates and include QW active elements and GaAs/InGaP photonic crystal (PC) layer situated above this active zone. Atoms of triangular shapes have been shown to increase optical power from the PCSEL but are also shown to result in a competition between lasing modes. Simulation shows that the energy splitting of lasing modes is smaller for triangular atoms, than for circles making high power single-mode devices difficult to achieve. In this work we experimentally investigate the effect of lateral optical feedback introduced by a facet cleave along one or two perpendicular PCSEL edges. This cleavage plane is misaligned to the PC resulting in a periodic variation of facet phase along the side of the device. Results confirm that a single cleave selects the lowest threshold 2D lasing mode, resulting in a 20% reduction in threshold current and favours single-mode emission. The addition of a second cleave at right-angles to the first has no significant effect upon threshold current. The virgin device is shown to have a symmetric far-field (1 degree) whilst a single cleave produces a 1 degree divergence perpendicular to cleave and 5 degree parallel to cleave. The second orthogonal cleave results in the far field becoming symmetric again but with a divergence angle of 1 degree indicating that single-mode lasing is supported over a wider area.

  19. Measuring patient tolerance for future adverse events in low-risk emergency department chest pain patients.

    PubMed

    Chen, Jennifer C; Cooper, Richelle J; Lopez-O'Sullivan, Ana; Schriger, David L

    2014-08-01

    We assess emergency department (ED) patients' risk thresholds for preferring admission versus discharge when presenting with chest pain and determine how the method of information presentation affects patients' choices. In this cross-sectional survey, we enrolled a convenience sample of lower-risk acute chest pain patients from an urban ED. We presented patients with a hypothetical value for the risk of adverse outcome that could be decreased by hospitalization and asked them to identify the risk threshold at which they preferred admission versus discharge. We randomized patients to a method of numeric presentation (natural frequency or percentage) and the initial risk presented (low or high) and followed each numeric assessment with an assessment based on visually depicted risks. We enrolled 246 patients and analyzed data on 234 with complete information. The geometric mean risk threshold with numeric presentation was 1 in 736 (1 in 233 with a percentage presentation; 1 in 2,425 with a natural frequency presentation) and 1 in 490 with a visual presentation. Fifty-nine percent of patients (137/234) chose the lowest or highest risk values offered. One hundred fourteen patients chose different thresholds for numeric and visual risk presentations. We observed strong anchoring effects; patients starting with the lowest risk chose a lower threshold than those starting with the highest risk possible and vice versa. Using an expected utility model to measure patients' risk thresholds does not seem to work, either to find a stable risk preference within individuals or in groups. Further work in measurement of patients' risk tolerance or methods of shared decisionmaking not dependent on assessment of risk tolerance is needed. Copyright © 2014 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  20. Field hearing measurements of the Atlantic sharpnose shark Rhizoprionodon terraenovae.

    PubMed

    Casper, B M; Mann, D A

    2009-12-01

    Field measurements of hearing thresholds were obtained from the Atlantic sharpnose shark Rhizoprionodon terraenovae using the auditory evoked potential method (AEP). The fish had most sensitive hearing at 20 Hz, the lowest frequency tested, with decreasing sensitivity at higher frequencies. Hearing thresholds were lower than AEP thresholds previously measured for the nurse shark Ginglymostoma cirratum and yellow stingray Urobatis jamaicensis at frequencies <200 Hz, and similar at 200 Hz and above. Rhizoprionodon terraenovae represents the closest comparison in terms of pelagic lifestyle to the sharks which have been observed in acoustic field attraction experiments. The sound pressure levels that would be equivalent to the particle acceleration thresholds of R. terraenovae were much higher than the sound levels which attracted closely related sharks suggesting a discrepancy between the hearing threshold experiments and the field attraction experiments.

  1. Motor unit recruitment and derecruitment induced by brief increase in contraction amplitude of the human trapezius muscle

    PubMed Central

    Westad, C; Westgaard, R H; De Luca, C J

    2003-01-01

    The activity pattern of low-threshold human trapezius motor units was examined in response to brief, voluntary increases in contraction amplitude (‘EMG pulse’) superimposed on a constant contraction at 4–7% of the surface electromyographic (EMG) response at maximal voluntary contraction (4–7% EMGmax). EMG pulses at 15–20% EMGmax were superimposed every minute on contractions of 5, 10, or 30 min duration. A quadrifilar fine-wire electrode recorded single motor unit activity and a surface electrode recorded simultaneously the surface EMG signal. Low-threshold motor units recruited at the start of the contraction were observed to stop firing while motor units of higher recruitment threshold stayed active. Derecruitment of a motor unit coincided with the end of an EMG pulse. The lowest-threshold motor units showed only brief silent periods. Some motor units with recruitment threshold up to 5% EMGmax higher than the constant contraction level were recruited during an EMG pulse and kept firing throughout the contraction. Following an EMG pulse, there was a marked reduction in motor unit firing rates upon return of the surface EMG signal to the constant contraction level, outlasting the EMG pulse by 4 s on average. The reduction in firing rates may serve as a trigger to induce derecruitment. We speculate that the silent periods following derecruitment may be due to deactivation of non-inactivating inward current (‘plateau potentials’). The firing behaviour of trapezius motor units in these experiments may thus illustrate a mechanism and a control strategy to reduce fatigue of motor units with sustained activity patterns. PMID:14561844

  2. InAs(PSb)-based ``W'' quantum well laser diodes emitting near 3.3 μm

    NASA Astrophysics Data System (ADS)

    Joullié, A.; Skouri, E. M.; Garcia, M.; Grech, P.; Wilk, A.; Christol, P.; Baranov, A. N.; Behres, A.; Kluth, J.; Stein, A.; Heime, K.; Heuken, M.; Rushworth, S.; Hulicius, E.; Simecek, T.

    2000-05-01

    Mid-infrared laser diodes with an active region consisting of five "W" InAsSb/InAsP/InAsSb/InAsPSb quantum wells and broad InAsPSb waveguide were fabricated by metalorganic vapor phase epitaxy on InAs substrates. Laser emission was demonstrated at 3.3 μm up to 135 K from asymmetrical structures having n-type InAsPSb and p-type InPSb cladding layers. The devices operated in pulsed regime at 3.3 μm, with a lowest threshold current density of 120 A/cm2 at 90 K, and an output power efficiency of 31 mW/facet/A. The characteristic temperature was 35 K.

  3. Convergence of decision rules for value-based pricing of new innovative drugs.

    PubMed

    Gandjour, Afschin

    2015-04-01

    Given the high costs of innovative new drugs, most European countries have introduced policies for price control, in particular value-based pricing (VBP) and international reference pricing. The purpose of this study is to describe how profit-maximizing manufacturers would optimally adjust their launch sequence to these policies and how VBP countries may best respond. To decide about the launching sequence, a manufacturer must consider a tradeoff between price and sales volume in any given country as well as the effect of price in a VBP country on the price in international reference pricing countries. Based on the manufacturer's rationale, it is best for VBP countries in Europe to implicitly collude in the long term and set cost-effectiveness thresholds at the level of the lowest acceptable VBP country. This way, international reference pricing countries would also converge towards the lowest acceptable threshold in Europe.

  4. Proton threshold states in the {sup 22}Na(p,{gamma}){sup 23}Mg reaction and astrophysical implications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Comisel, H.; Hategan, C.; Graw, G.

    Proton threshold states in {sup 23}Mg are important for the astrophysically relevant proton capture reaction {sup 22}Na(p,{gamma}){sup 23}Mg. In the indirect determination of the resonance strength of the lowest states, which were not accessible by direct methods, some of the spin-parity-assignments remained experimentally uncertain. We have investigated these states with shell model, Coulomb displacement, and Thomas-Ehrman shift calculations. From the comparison of calculated and observed properties, we relate the lowest relevant resonance state at E{sub x}=7643 keV to an excited 3/2{sup +} state in accordance with a recent experimental determination by Jenkins et al. From this we deduce significantly improvedmore » values for the {sup 22}Na(p,{gamma}){sup 23}Mg reaction rate at stellar temperatures below T{sub 9}=0.1 K.« less

  5. Behavioural Response Thresholds in New Zealand Crab Megalopae to Ambient Underwater Sound

    PubMed Central

    Stanley, Jenni A.; Radford, Craig A.; Jeffs, Andrew G.

    2011-01-01

    A small number of studies have demonstrated that settlement stage decapod crustaceans are able to detect and exhibit swimming, settlement and metamorphosis responses to ambient underwater sound emanating from coastal reefs. However, the intensity of the acoustic cue required to initiate the settlement and metamorphosis response, and therefore the potential range over which this acoustic cue may operate, is not known. The current study determined the behavioural response thresholds of four species of New Zealand brachyuran crab megalopae by exposing them to different intensity levels of broadcast reef sound recorded from their preferred settlement habitat and from an unfavourable settlement habitat. Megalopae of the rocky-reef crab, Leptograpsus variegatus, exhibited the lowest behavioural response threshold (highest sensitivity), with a significant reduction in time to metamorphosis (TTM) when exposed to underwater reef sound with an intensity of 90 dB re 1 µPa and greater (100, 126 and 135 dB re 1 µPa). Megalopae of the mud crab, Austrohelice crassa, which settle in soft sediment habitats, exhibited no response to any of the underwater reef sound levels. All reef associated species exposed to sound levels from an unfavourable settlement habitat showed no significant change in TTM, even at intensities that were similar to their preferred reef sound for which reductions in TTM were observed. These results indicated that megalopae were able to discern and respond selectively to habitat-specific acoustic cues. The settlement and metamorphosis behavioural response thresholds to levels of underwater reef sound determined in the current study of four species of crabs, enables preliminary estimation of the spatial range at which an acoustic settlement cue may be operating, from 5 m to 40 km depending on the species. Overall, these results indicate that underwater sound is likely to play a major role in influencing the spatial patterns of settlement of coastal crab species. PMID:22163314

  6. Tuning nonlinear optical absorption properties of WS₂ nanosheets.

    PubMed

    Long, Hui; Tao, Lili; Tang, Chun Yin; Zhou, Bo; Zhao, Yuda; Zeng, Longhui; Yu, Siu Fung; Lau, Shu Ping; Chai, Yang; Tsang, Yuen Hong

    2015-11-14

    To control the optical properties of two-dimensional (2D) materials is a long-standing goal, being of both fundamental and technological significance. Tuning nonlinear optical absorption (NOA) properties of 2D transition metal dichalcogenides in a cost effective way has emerged as an important research topic because of its possibility to custom design NOA properties, implying enormous applications including optical computers, communications, bioimaging, and so on. In this study, WS2 with different size and thickness distributions was fabricated. The results demonstrate that both NOA onset threshold, F(ON), and optical limiting threshold, F(OL), of WS2 under the excitation of a nanosecond pulsed laser can be tuned over a wide range by controlling its size and thickness. The F(ON) and F(OL) show a rapid decline with the decrease of size and thickness. Due to the edge and quantum confinement effect, WS2 quantum dots (2.35 nm) exhibit the lowest F(ON) (0.01 J cm(-2)) and F(OL) (0.062 J cm(-2)) among all the samples, which are comparable to the lowest threshold achieved in graphene based materials, showing great potential as NOA materials with tunable properties.

  7. Stress-strain analysis of contractility in the ileum in response to flow and ramp distension in streptozotocin-induced diabetic rats--association with advanced glycation end product formation.

    PubMed

    Zhao, Jingbo; Chen, Pengmin; Gregersen, Hans

    2015-04-13

    This study compared the ileal contractility and analyzed the association between contractility with advanced glycation end product (AGE) formation in normal and streptozotocin (STZ)-induced diabetic rats. Nine STZ-induced diabetic rats (Diabetes group) and 9 normal rats (Normal group) were used. The motility experiments were carried out on ileums in organ baths containing physiological Krebs solution. Ileal pressure and diameter changes were obtained from basic, flow-induced and ramp distension-induced contractions. The frequency and amplitude of contractions were analyzed from pressure-diameter curves. Distension-induced contraction thresholds and maximum contraction amplitude of basic and flow-induced contractions were calculated in terms of stress and strain. AGE and its receptor (RAGE) in the layers were detected by immunohistochemistry staining. The maximum stress of flow-induced contractions was lowest in the Diabetes Group (P<0.05). During ramp distension, the pressure and stress thresholds and Young's modulus to induce phasic contraction were lowest in the Diabetes Group (P<0.05 and P<0.01). AGE and RAGE expressions in the different ileum layers were highest in the Diabetes group. The contraction pressure and stress thresholds were significantly associated with AGE expression in the muscle layer and RAGE expression in mucosa epithelium and neurons. The diabetic intestine was hypersensitive to distension for contraction induction. However, the contraction force produced by smooth muscle was lowest in diabetic rats. Increased AGE/RAGE expression was associated with the contractility changes in diabetic rats. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Effects Of Radiation On Insulators

    NASA Technical Reports Server (NTRS)

    Bouquet, Frank L.

    1988-01-01

    Report presents data on responses of electrically insulating thermosetting and thermoplastic polymers to radiation. Lowest-threshold-dose (LTD) levels and 25-percent-change levels presented for such properties as tensile strength and electrical resistivity. Data on radiation-induced outgassing also given.

  9. A novel optic bistable device with very low threshold intensity using photorefractive films

    NASA Astrophysics Data System (ADS)

    Wang, Sean X.; Sun, Yuankun; Trivedi, Sudhir B.; Li, Guifang

    1994-08-01

    Brimrose Corporation of America reports the successful completion of the SBIR Phase I research in low-threshold intensity optical bistable devices using photorefractive nonlinearity. A thin photorefractive film optical bistable device was proposed in the Phase I proposal. The feasibility of this device was theoretically investigated. The theoretical feasibility study formulates the materials requirements in such a kind of configuration for Phase II research. In addition, we have proposed and investigated another configuration of optical bistable devices that do not require advanced photorefractive materials, namely, the self-pumped phase conjugator. We have successfully demonstrated a low-threshold optical bistable operation in a KNSBN:CU crystal. To the best of our knowledge, the threshold of 650 mW/sq. cm is the lowest of its kind to be achieved so far.

  10. Killer whale (Orcinus orca) behavioral audiograms.

    PubMed

    Branstetter, Brian K; St Leger, Judy; Acton, Doug; Stewart, John; Houser, Dorian; Finneran, James J; Jenkins, Keith

    2017-04-01

    Killer whales (Orcinus orca) are one of the most cosmopolitan marine mammal species with potential widespread exposure to anthropogenic noise impacts. Previous audiometric data on this species were from two adult females [Szymanski, Bain, Kiehl, Pennington, Wong, and Henry (1999). J. Acoust. Soc. Am. 108, 1322-1326] and one sub-adult male [Hall and Johnson (1972). J. Acoust. Soc. Am. 51, 515-517] with apparent high-frequency hearing loss. All three killer whales had best sensitivity between 15 and 20 kHz, with thresholds lower than any odontocete tested to date, suggesting this species might be particularly sensitive to acoustic disturbance. The current study reports the behavioral audiograms of eight killer whales at two different facilities. Hearing sensitivity was measured from 100 Hz to 160 kHz in killer whales ranging in age from 12 to 52 year. Previously measured low thresholds at 20 kHz were not replicated in any individual. Hearing in the killer whales was generally similar to other delphinids, with lowest threshold (49 dB re 1 μPa) at approximately 34 kHz, good hearing (i.e., within 20 dB of best sensitivity) from 5 to 81 kHz, and low- and high-frequency hearing cutoffs (>100 dB re μPa) of 600 Hz and 114 kHz, respectively.

  11. The lowest ionization potentials of Al2

    NASA Technical Reports Server (NTRS)

    Bauschlicher, Charles W., Jr.; Barnes, Leslie A.; Taylor, Peter R.

    1988-01-01

    Potential curves for the lowest two electronic states (X 2 sigma g + and A 2 pi u) of Al2(+) were computed using complete active space SCF/multireference CI wave functions and large Gaussian basis sets. The lowest observable vertical ionization potential (to Al2(+) X 2 sigma g +) of the Al2 X 3 pi u ground state is calculated to occur around 6.1 eV, in excellent agreement with the experimental range of 6.0 to 6.42 eV obtained in recent cluster ionization studies by Cox and co-workers. The second vertical ionization potential (to Al2(+) A 2 pi u) occurs near 6.4 eV, also within the experimental range. The adiabatic IP of 5.90 eV is in good agreement with the value of 5.8 to 6.1 eV deduced by Hanley and co-workers from the difference in thresholds between collision induced dissociation processes of Al3(+). The computed IP values are somewhat larger than those deduced from branching ratios in cluster fragmentation experiments by Jarrold and co-workers. The observation of an ionization threshold below 6.42 eV is shown to be incompatible with an Al2 ground electronic state assignment of 3 sigma g -, but the separation between the two lowest states of Al2 is so small that it is likely that both are populated in the experiments, so that this does not provide unambiguous support for the recent theoretical assignment of the ground state as 3 pi u.

  12. Risk thresholds for alcohol consumption: combined analysis of individual-participant data for 599 912 current drinkers in 83 prospective studies.

    PubMed

    Wood, Angela M; Kaptoge, Stephen; Butterworth, Adam S; Willeit, Peter; Warnakula, Samantha; Bolton, Thomas; Paige, Ellie; Paul, Dirk S; Sweeting, Michael; Burgess, Stephen; Bell, Steven; Astle, William; Stevens, David; Koulman, Albert; Selmer, Randi M; Verschuren, W M Monique; Sato, Shinichi; Njølstad, Inger; Woodward, Mark; Salomaa, Veikko; Nordestgaard, Børge G; Yeap, Bu B; Fletcher, Astrid; Melander, Olle; Kuller, Lewis H; Balkau, Beverley; Marmot, Michael; Koenig, Wolfgang; Casiglia, Edoardo; Cooper, Cyrus; Arndt, Volker; Franco, Oscar H; Wennberg, Patrik; Gallacher, John; de la Cámara, Agustín Gómez; Völzke, Henry; Dahm, Christina C; Dale, Caroline E; Bergmann, Manuela M; Crespo, Carlos J; van der Schouw, Yvonne T; Kaaks, Rudolf; Simons, Leon A; Lagiou, Pagona; Schoufour, Josje D; Boer, Jolanda M A; Key, Timothy J; Rodriguez, Beatriz; Moreno-Iribas, Conchi; Davidson, Karina W; Taylor, James O; Sacerdote, Carlotta; Wallace, Robert B; Quiros, J Ramon; Tumino, Rosario; Blazer, Dan G; Linneberg, Allan; Daimon, Makoto; Panico, Salvatore; Howard, Barbara; Skeie, Guri; Strandberg, Timo; Weiderpass, Elisabete; Nietert, Paul J; Psaty, Bruce M; Kromhout, Daan; Salamanca-Fernandez, Elena; Kiechl, Stefan; Krumholz, Harlan M; Grioni, Sara; Palli, Domenico; Huerta, José M; Price, Jackie; Sundström, Johan; Arriola, Larraitz; Arima, Hisatomi; Travis, Ruth C; Panagiotakos, Demosthenes B; Karakatsani, Anna; Trichopoulou, Antonia; Kühn, Tilman; Grobbee, Diederick E; Barrett-Connor, Elizabeth; van Schoor, Natasja; Boeing, Heiner; Overvad, Kim; Kauhanen, Jussi; Wareham, Nick; Langenberg, Claudia; Forouhi, Nita; Wennberg, Maria; Després, Jean-Pierre; Cushman, Mary; Cooper, Jackie A; Rodriguez, Carlos J; Sakurai, Masaru; Shaw, Jonathan E; Knuiman, Matthew; Voortman, Trudy; Meisinger, Christa; Tjønneland, Anne; Brenner, Hermann; Palmieri, Luigi; Dallongeville, Jean; Brunner, Eric J; Assmann, Gerd; Trevisan, Maurizio; Gillum, Richard F; Ford, Ian; Sattar, Naveed; Lazo, Mariana; Thompson, Simon G; Ferrari, Pietro; Leon, David A; Smith, George Davey; Peto, Richard; Jackson, Rod; Banks, Emily; Di Angelantonio, Emanuele; Danesh, John

    2018-04-14

    Low-risk limits recommended for alcohol consumption vary substantially across different national guidelines. To define thresholds associated with lowest risk for all-cause mortality and cardiovascular disease, we studied individual-participant data from 599 912 current drinkers without previous cardiovascular disease. We did a combined analysis of individual-participant data from three large-scale data sources in 19 high-income countries (the Emerging Risk Factors Collaboration, EPIC-CVD, and the UK Biobank). We characterised dose-response associations and calculated hazard ratios (HRs) per 100 g per week of alcohol (12·5 units per week) across 83 prospective studies, adjusting at least for study or centre, age, sex, smoking, and diabetes. To be eligible for the analysis, participants had to have information recorded about their alcohol consumption amount and status (ie, non-drinker vs current drinker), plus age, sex, history of diabetes and smoking status, at least 1 year of follow-up after baseline, and no baseline history of cardiovascular disease. The main analyses focused on current drinkers, whose baseline alcohol consumption was categorised into eight predefined groups according to the amount in grams consumed per week. We assessed alcohol consumption in relation to all-cause mortality, total cardiovascular disease, and several cardiovascular disease subtypes. We corrected HRs for estimated long-term variability in alcohol consumption using 152 640 serial alcohol assessments obtained some years apart (median interval 5·6 years [5th-95th percentile 1·04-13·5]) from 71 011 participants from 37 studies. In the 599 912 current drinkers included in the analysis, we recorded 40 310 deaths and 39 018 incident cardiovascular disease events during 5·4 million person-years of follow-up. For all-cause mortality, we recorded a positive and curvilinear association with the level of alcohol consumption, with the minimum mortality risk around or below 100 g per week. Alcohol consumption was roughly linearly associated with a higher risk of stroke (HR per 100 g per week higher consumption 1·14, 95% CI, 1·10-1·17), coronary disease excluding myocardial infarction (1·06, 1·00-1·11), heart failure (1·09, 1·03-1·15), fatal hypertensive disease (1·24, 1·15-1·33); and fatal aortic aneurysm (1·15, 1·03-1·28). By contrast, increased alcohol consumption was log-linearly associated with a lower risk of myocardial infarction (HR 0·94, 0·91-0·97). In comparison to those who reported drinking >0-≤100 g per week, those who reported drinking >100-≤200 g per week, >200-≤350 g per week, or >350 g per week had lower life expectancy at age 40 years of approximately 6 months, 1-2 years, or 4-5 years, respectively. In current drinkers of alcohol in high-income countries, the threshold for lowest risk of all-cause mortality was about 100 g/week. For cardiovascular disease subtypes other than myocardial infarction, there were no clear risk thresholds below which lower alcohol consumption stopped being associated with lower disease risk. These data support limits for alcohol consumption that are lower than those recommended in most current guidelines. UK Medical Research Council, British Heart Foundation, National Institute for Health Research, European Union Framework 7, and European Research Council. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.

  13. Excitation of lowest electronic states of the uracil molecule by slow electrons

    NASA Astrophysics Data System (ADS)

    Chernyshova, I. V.; Kontros, J. E.; Markush, P. P.; Shpenik, O. B.

    2012-07-01

    The excitation of lowest electronic states of the uracil molecule in the gas phase has been studied by electron energy loss spectroscopy. Along with excitation of lowest singlet states, excitation of two lowest triplet states at 3.75 and 4.76 eV (±0.05 eV) and vibrational excitation of the molecule in two resonant ranges (1-2 and 3-4 eV) have been observed for the first time. The peak of the excitation band related to the lowest singlet state (5.50 eV) is found to be blueshifted by 0.4 eV in comparison with the optical absorption spectroscopy data. The threshold excitation spectra have been measured for the first time, with detection of electrons inelastically scattered by an angle of 180°. These spectra exhibit clear separation of the 5.50-eV-wide band into two bands, which are due to the excitation of the triplet 13 A″ and singlet 11 A' states.

  14. Low threshold diode-pumped picosecond mode-locked Nd:YAG laser with a semiconductor saturable absorber mirror

    NASA Astrophysics Data System (ADS)

    Eshghi, M. J.; Majdabadi, A.; Koohian, A.

    2017-01-01

    In this paper, a low threshold diode pumped passively mode-locked Nd:YAG laser has been demonstrated by using a semiconductor saturable absorber mirror. The threshold power for continuous-wave mode-locking is relatively low, about 3.2 W. The resonator stability across the pump power has been analytically examined. Moreover, the mode overlap between the pump beam and the laser fundamental mode has been simulated by MATLAB software. Adopting Z-shaped resonator configuration and suitable design of the resonator’s arm lengths, has enabled the author to prepare mode-locking conditions, and obtain 40 ps pulses with 112 MHz pulse repetition rate. The laser output was stable without any Q switched instability. To the best of our knowledge, this is the lowest threshold for CW mode-locking operation of a Nd:YAG laser.

  15. Global Instrumental Seismic Catalog: earthquake relocations for 1900-present

    NASA Astrophysics Data System (ADS)

    Villasenor, A.; Engdahl, E.; Storchak, D. A.; Bondar, I.

    2010-12-01

    We present the current status of our efforts to produce a set of homogeneous earthquake locations and improved focal depths towards the compilation of a Global Catalog of instrumentally recorded earthquakes that will be complete down to the lowest magnitude threshold possible on a global scale and for the time period considered. This project is currently being carried out under the auspices of GEM (Global Earthquake Model). The resulting earthquake catalog will be a fundamental dataset not only for earthquake risk modeling and assessment on a global scale, but also for a large number of studies such as global and regional seismotectonics; the rupture zones and return time of large, damaging earthquakes; the spatial-temporal pattern of moment release along seismic zones and faults etc. Our current goal is to re-locate all earthquakes with available station arrival data using the following magnitude thresholds: M5.5 for 1964-present, M6.25 for 1918-1963, M7.5 (complemented with significant events in continental regions) for 1900-1917. Phase arrival time data for earthquakes after 1963 are available in digital form from the International Seismological Centre (ISC). For earthquakes in the time period 1918-1963, phase data is obtained by scanning the printed International Seismological Summary (ISS) bulletins and applying optical character recognition routines. For earlier earthquakes we will collect phase data from individual station bulletins. We will illustrate some of the most significant results of this relocation effort, including aftershock distributions for large earthquakes, systematic differences in epicenter and depth with respect to previous location, examples of grossly mislocated events, etc.

  16. EMG biofeedback: the effects of CRF, FR, VR, FI, and VI schedules of reinforcement on the acquisition and extinction of increases in forearm muscle tension.

    PubMed

    Cohen, S L; Richardson, J; Klebez, J; Febbo, S; Tucker, D

    2001-09-01

    Biofeedback was used to increase forearm-muscle tension. Feedback was delivered under continuous reinforcement (CRF), variable interval (VI), fixed interval (FI), variable ratio (VR), and fixed ratio (FR) schedules of reinforcement when college students increased their muscle tension (electromyograph, EMG) above a high threshold. There were three daily sessions of feedback, and Session 3 was immediately followed by a session without feedback (extinction). The CRF schedule resulted in the highest EMG, closely followed by the FR and VR schedules, and the lowest EMG scores were produced by the FI and VI schedules. Similarly, the CRF schedule resulted in the greatest amount of time-above-threshold and the VI and FI schedules produced the lowest time-above-threshold. The highest response rates were generated by the FR schedule, followed by the VR schedule. The CRF schedule produced relatively low response rates, comparable to the rates under the VI and FI schedules. Some of the data are consistent with the partial-reinforcement-extinction effect. The present data suggest that different schedules of feedback should be considered in muscle-strengthening-contexts such as during the rehabilitation of muscles following brain damage or peripheral nervous-system injury.

  17. Stochastic processes in gravitropism.

    PubMed

    Meroz, Yasmine; Bastien, Renaud

    2014-01-01

    In this short review we focus on the role of noise in gravitropism of plants - the reorientation of plants according to the direction of gravity. We briefly introduce the conventional picture of static gravisensing in cells specialized in sensing. This model hinges on the sedimentation of statoliths (high in density and mass relative to other organelles) to the lowest part of the sensing cell. We then present experimental observations that cannot currently be understood within this framework. Lastly we introduce some current alternative models and directions that attempt to incorporate and interpret these experimental observations, including: (i) dynamic sensing, where gravisensing is suggested to be enhanced by stochastic events due to thermal and mechanical noise. These events both effectively lower the threshold of response, and lead to small-distance sedimentation, allowing amplification, and integration of the signal. (ii) The role of the cytoskeleton in signal-to-noise modulation and (iii) in signal transduction. In closing, we discuss directions that seem to either not have been explored, or that are still poorly understood.

  18. Rate-Compatible Protograph LDPC Codes

    NASA Technical Reports Server (NTRS)

    Nguyen, Thuy V. (Inventor); Nosratinia, Aria (Inventor); Divsalar, Dariush (Inventor)

    2014-01-01

    Digital communication coding methods resulting in rate-compatible low density parity-check (LDPC) codes built from protographs. Described digital coding methods start with a desired code rate and a selection of the numbers of variable nodes and check nodes to be used in the protograph. Constraints are set to satisfy a linear minimum distance growth property for the protograph. All possible edges in the graph are searched for the minimum iterative decoding threshold and the protograph with the lowest iterative decoding threshold is selected. Protographs designed in this manner are used in decode and forward relay channels.

  19. Electroconvulsive therapy stimulus titration: Not all it seems.

    PubMed

    Rosenman, Stephen J

    2018-05-01

    To examine the provenance and implications of seizure threshold titration in electroconvulsive therapy. Titration of seizure threshold has become a virtual standard for electroconvulsive therapy. It is justified as individualisation and optimisation of the balance between efficacy and unwanted effects. Present day threshold estimation is significantly different from the 1960 studies of Cronholm and Ottosson that are its usual justification. The present form of threshold estimation is unstable and too uncertain for valid optimisation or individualisation of dose. Threshold stimulation (lowest dose that produces a seizure) has proven therapeutically ineffective, and the multiples applied to threshold to attain efficacy have never been properly investigated or standardised. The therapeutic outcomes of threshold estimation (or its multiples) have not been separated from simple dose effects. Threshold estimation does not optimise dose due to its own uncertainties and the different short-term and long-term cognitive and memory effects. Potential harms of titration have not been examined. Seizure threshold titration in electroconvulsive therapy is not a proven technique of dose optimisation. It is widely held and practiced; its benefit and harmlessness assumed but unproven. It is a prematurely settled answer to an unsettled question that discourages further enquiry. It is an example of how practices, assumed scientific, enter medicine by obscure paths.

  20. Identifying cochlear implant channels with poor electrode-neuron interfaces: electrically evoked auditory brain stem responses measured with the partial tripolar configuration.

    PubMed

    Bierer, Julie Arenberg; Faulkner, Kathleen F; Tremblay, Kelly L

    2011-01-01

    The goal of this study was to compare cochlear implant behavioral measures and electrically evoked auditory brain stem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves. The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, defined as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping session, especially for young children. Here, we have extended the previous investigation to determine whether a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ = 1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ = 0) and a more focused partial tripolar (σ ≥ 0.50) configuration. Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds obtained with both the monopolar and partial tripolar configurations. The Wave V amplitude growth functions with increasing stimulus level showed the predicted effect of shallower growth for the partial tripolar than for the monopolar configuration, but this was observed only for the low-threshold channels. In contrast, high-threshold channels showed the opposite effect; steeper growth functions were seen for the partial tripolar configuration. These results suggest that behavioral thresholds or EABRs measured with a restricted stimulus can be used to identify potentially impaired cochlear implant channels. Channels having high thresholds and steep growth functions would likely not activate the appropriate spatially restricted region of the cochlea, leading to suboptimal perception. As a clinical tool, quick identification of impaired channels could lead to patient-specific mapping strategies and result in improved speech and music perception.

  1. Influence of the chemical structure on odor qualities and odor thresholds of halogenated guaiacol-derived odorants

    NASA Astrophysics Data System (ADS)

    Juhlke, Florian; Lorber, Katja; Wagenstaller, Maria; Buettner, Andrea

    2017-12-01

    Chlorinated guaiacol derivatives are found in waste water of pulp mills using chlorine in the bleaching process of wood pulp. They can also be detected in fish tissue, possibly causing off-odors. To date, there is no systematic investigation on the odor properties of halogenated guaiacol derivatives. To close this gap, odor thresholds in air and odor qualities of 14 compounds were determined by gas chromatography-olfactometry. Overall, the investigated compounds elicited smells that are characteristic for guaiacol, namely smoky, sweet, vanilla-like, but also medicinal and plaster-like. Their odor thresholds in air were, however, very low, ranging from 0.00072 to 23 ng/Lair. The lowest thresholds were found for 5-chloro- and 5-bromoguaiacol, followed by 4,5-dichloro- and 6-chloroguaiacol. Moreover, some inter-individual differences in odor threshold values could be observed, with the highest variations having been recorded for the individual values of 5-iodo- and 4-bromoguaiacol.

  2. Contributions of adaptation currents to dynamic spike threshold on slow timescales: Biophysical insights from conductance-based models

    NASA Astrophysics Data System (ADS)

    Yi, Guosheng; Wang, Jiang; Wei, Xile; Deng, Bin; Li, Huiyan; Che, Yanqiu

    2017-06-01

    Spike-frequency adaptation (SFA) mediated by various adaptation currents, such as voltage-gated K+ current (IM), Ca2+-gated K+ current (IAHP), or Na+-activated K+ current (IKNa), exists in many types of neurons, which has been shown to effectively shape their information transmission properties on slow timescales. Here we use conductance-based models to investigate how the activation of three adaptation currents regulates the threshold voltage for action potential (AP) initiation during the course of SFA. It is observed that the spike threshold gets depolarized and the rate of membrane depolarization (dV/dt) preceding AP is reduced as adaptation currents reduce firing rate. It is indicated that the presence of inhibitory adaptation currents enables the neuron to generate a dynamic threshold inversely correlated with preceding dV/dt on slower timescales than fast dynamics of AP generation. By analyzing the interactions of ionic currents at subthreshold potentials, we find that the activation of adaptation currents increase the outward level of net membrane current prior to AP initiation, which antagonizes inward Na+ to result in a depolarized threshold and lower dV/dt from one AP to the next. Our simulations demonstrate that the threshold dynamics on slow timescales is a secondary effect caused by the activation of adaptation currents. These findings have provided a biophysical interpretation of the relationship between adaptation currents and spike threshold.

  3. Interpreting ecological diversity indices applied to terminal restriction fragment length polymorphism data: insights from simulated microbial communities.

    PubMed

    Blackwood, Christopher B; Hudleston, Deborah; Zak, Donald R; Buyer, Jeffrey S

    2007-08-01

    Ecological diversity indices are frequently applied to molecular profiling methods, such as terminal restriction fragment length polymorphism (T-RFLP), in order to compare diversity among microbial communities. We performed simulations to determine whether diversity indices calculated from T-RFLP profiles could reflect the true diversity of the underlying communities despite potential analytical artifacts. These include multiple taxa generating the same terminal restriction fragment (TRF) and rare TRFs being excluded by a relative abundance (fluorescence) threshold. True community diversity was simulated using the lognormal species abundance distribution. Simulated T-RFLP profiles were generated by assigning each species a TRF size based on an empirical or modeled TRF size distribution. With a typical threshold (1%), the only consistently useful relationship was between Smith and Wilson evenness applied to T-RFLP data (TRF-E(var)) and true Shannon diversity (H'), with correlations between 0.71 and 0.81. TRF-H' and true H' were well correlated in the simulations using the lowest number of species, but this correlation declined substantially in simulations using greater numbers of species, to the point where TRF-H' cannot be considered a useful statistic. The relationships between TRF diversity indices and true indices were sensitive to the relative abundance threshold, with greatly improved correlations observed using a 0.1% threshold, which was investigated for comparative purposes but is not possible to consistently achieve with current technology. In general, the use of diversity indices on T-RFLP data provides inaccurate estimates of true diversity in microbial communities (with the possible exception of TRF-E(var)). We suggest that, where significant differences in T-RFLP diversity indices were found in previous work, these should be reinterpreted as a reflection of differences in community composition rather than a true difference in community diversity.

  4. Neodymium: YAG laser damage threshold. A comparison of injection-molded and lathe-cut polymethylmethacrylate intraocular lenses.

    PubMed

    Wilson, S E; Brubaker, R F

    1987-01-01

    The possibility that injection-molded intraocular lenses (IOLs) with imperfections called iridescent clefts could have a decreased threshold to neodymium: YAG (Nd:YAG) laser-induced damage was investigated. Thresholds for Nd:YAG laser-induced damage were determined for injection-molded and lathe-cut polymethylmethacrylate lenses. When aimed at a membrane in contact with a posterior convex surface, the average thresholds were 0.96 +/- 0.18 mJ (Standard deviation [SD]) and 1.80 +/- 0.55 mJ, respectively. The difference was significant at P = 0.001. When injection-molding polymethylmethacrylate was used to make lathe-cut IOLs, very few iridescent clefts were present, and the threshold to Nd:YAG laser-induced damage was 0.94 +/- 0.25 mJ. Iridescent clefts are therefore produced during the injection-molding process but they do not lower the threshold to Nd:YAG laser-induced damage. Rather, the reduced threshold in injection-molded lenses is most probably a result of the polymethylmethacrylate used in their manufacture. Clinically, iridescent clefts in a lens suggest that it has been manufactured by an injection-molding process and that Nd:YAG laser posterior capsulotomy must be performed at the lowest possible energy level to avoid damage.

  5. Ballooning modes localized near the null point of a divertor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farmer, W. A.; Lawrence Livermore National Laboratory, 7000 East Ave., Livermore, California 94550

    2014-04-15

    The stability of ballooning modes localized to the null point in both the standard and snowflake divertors is considered. Ideal magnetohydrodynamics is used. A series expansion of the flux function is performed in the vicinity of the null point with the lowest, non-vanishing term retained for each divertor configuration. The energy principle is used with a trial function to determine a sufficient instability threshold. It is shown that this threshold depends on the orientation of the flux surfaces with respect to the major radius with a critical angle appearing due to the convergence of the field lines away from themore » null point. When the angle the major radius forms with respect to the flux surfaces exceeds this critical angle, the system is stabilized. Further, the scaling of the instability threshold with the aspect ratio and the ratio of the scrape-off-layer width to the major radius is shown. It is concluded that ballooning modes are not a likely candidate for driving convection in the vicinity of the null for parameters relevant to existing machines. However, the results place a lower bound on the width of the heat flux in the private flux region. To explain convective mixing in the vicinity of the null point, new consideration should be given to an axisymmetric mixing mode [W. A. Farmer and D. D. Ryutov, Phys. Plasmas 20, 092117 (2013)] as a possible candidate to explain current experimental results.« less

  6. The diagnostic utility of separation anxiety disorder symptoms: An item response theory analysis

    PubMed Central

    Cooper-Vince, Christine E.; Emmert-Aronson, Benjamin O.; Pincus, Donna B.; Comer, Jonathan S.

    2013-01-01

    At present, it is not clear whether the current definition of separation anxiety disorder (SAD) is the optimal classification of developmentally inappropriate, severe, and interfering separation anxiety in youth. Much remains to be learned about the relative contributions of individual SAD symptoms for informing diagnosis. Two-parameter logistic Item Response Theory analyses were conducted on the eight core SAD symptoms in an outpatient anxiety sample of treatment-seeking children (N=359, 59.3% female, MAge=11.2) and their parents to determine the diagnostic utility of each of these symptoms. Analyses considered values of item threshold, which characterize the SAD severity level at which each symptom has a 50% chance of being endorsed, and item discrimination, which characterize how well each symptom distinguishes individuals with higher and lower levels of SAD. Distress related to separation and fear of being alone without major attachment figures showed the strongest discrimination properties and the lowest thresholds for being endorsed. In contrast, worry about harm befalling attachment figures showed the poorest discrimination properties, and nightmares about separation showed the highest threshold for being endorsed. Distress related to separation demonstrated crossing differential item functioning associated with age—at lower separation anxiety levels excessive fear at separation was more likely to be endorsed for children ≥9 years, whereas at higher levels this symptom was more likely to be endorsed by children <9 years. Implications are discussed for optimizing the taxonomy of SAD in youth. PMID:23963543

  7. AREA RADIATION MONITOR

    DOEpatents

    Manning, F.W.; Groothuis, S.E.; Lykins, J.H.; Papke, D.M.

    1962-06-12

    S>An improved area radiation dose monitor is designed which is adapted to compensate continuously for background radiation below a threshold dose rate and to give warning when the dose integral of the dose rate of an above-threshold radiation excursion exceeds a selected value. This is accomplished by providing means for continuously charging an ionization chamber. The chamber provides a first current proportional to the incident radiation dose rate. Means are provided for generating a second current including means for nulling out the first current with the second current at all values of the first current corresponding to dose rates below a selected threshold dose rate value. The second current has a maximum value corresponding to that of the first current at the threshold dose rate. The excess of the first current over the second current, which occurs above the threshold, is integrated and an alarm is given at a selected integrated value of the excess corresponding to a selected radiation dose. (AEC)

  8. Are Alcohol Taxation and Pricing Policies Regressive? Product-Level Effects of a Specific Tax and a Minimum Unit Price for Alcohol.

    PubMed

    Vandenberg, Brian; Sharma, Anurag

    2016-07-01

    To compare estimated effects of two policy alternatives, (i) a minimum unit price (MUP) for alcohol and (ii) specific (per-unit) taxation, upon current product prices, per capita spending (A$), and per capita consumption by income quintile, consumption quintile and product type. Estimation of baseline spending and consumption, and modelling policy-to-price and price-to-consumption effects of policy changes using scanner data from a panel of demographically representative Australian households that includes product-level details of their off-trade alcohol spending (n = 885; total observations = 12,505). Robustness checks include alternative price elasticities, tax rates, minimum price thresholds and tax pass-through rates. Current alcohol taxes and alternative taxation and pricing policies are not highly regressive. Any regressive effects are small and concentrated among heavy consumers. The lowest-income consumers currently spend a larger proportion of income (2.3%) on alcohol taxes than the highest-income consumers (0.3%), but the mean amount is small in magnitude [A$5.50 per week (95%CI: 5.18-5.88)]. Both a MUP and specific taxation will have some regressive effects, but the effects are limited, as they are greatest for the heaviest consumers, irrespective of income. Among the policy alternatives, a MUP is more effective in reducing consumption than specific taxation, especially for consumers in the lowest-income quintile: an estimated mean per capita reduction of 11.9 standard drinks per week (95%CI: 11.3-12.6). Policies that increase the cost of the cheapest alcohol can be effective in reducing alcohol consumption, without having highly regressive effects. © The Author 2015. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  9. Gender and dose dependent ovalbumin induced hypersensitivity responses in murine model of food allergy

    USDA-ARS?s Scientific Manuscript database

    While federal regulations mandate the labeling of major food allergens, allowable food allergen thresholds have yet to be determined. Therefore the aim of this project was to identify the lowest egg allergen ovalbumin (OVA) dose causing hypersensitization using a validated murine model. Mice were or...

  10. Gender and dose dependent ovalbumin induced hypersensitivity responses in murine model of food allergy

    USDA-ARS?s Scientific Manuscript database

    While federal regulations mandate the labeling of major food allergens, allowable food allergen thresholds have yet to be determined. Therefore the aim of this project was to identify the lowest egg allergen ovalbumin (OVA) dose causing hypersensitization using a validated murine model. Mice were o...

  11. Biophysical Insights into How Spike Threshold Depends on the Rate of Membrane Potential Depolarization in Type I and Type II Neurons

    PubMed Central

    Yi, Guo-Sheng; Wang, Jiang; Tsang, Kai-Ming; Wei, Xi-Le; Deng, Bin

    2015-01-01

    Dynamic spike threshold plays a critical role in neuronal input-output relations. In many neurons, the threshold potential depends on the rate of membrane potential depolarization (dV/dt) preceding a spike. There are two basic classes of neural excitability, i.e., Type I and Type II, according to input-output properties. Although the dynamical and biophysical basis of their spike initiation has been established, the spike threshold dynamic for each cell type has not been well described. Here, we use a biophysical model to investigate how spike threshold depends on dV/dt in two types of neuron. It is observed that Type II spike threshold is more depolarized and more sensitive to dV/dt than Type I. With phase plane analysis, we show that each threshold dynamic arises from the different separatrix and K+ current kinetics. By analyzing subthreshold properties of membrane currents, we find the activation of hyperpolarizing current prior to spike initiation is a major factor that regulates the threshold dynamics. The outward K+ current in Type I neuron does not activate at the perithresholds, which makes its spike threshold insensitive to dV/dt. The Type II K+ current activates prior to spike initiation and there is a large net hyperpolarizing current at the perithresholds, which results in a depolarized threshold as well as a pronounced threshold dynamic. These predictions are further attested in several other functionally equivalent cases of neural excitability. Our study provides a fundamental description about how intrinsic biophysical properties contribute to the threshold dynamics in Type I and Type II neurons, which could decipher their significant functions in neural coding. PMID:26083350

  12. Reliability and validity of a short form household food security scale in a Caribbean community.

    PubMed

    Gulliford, Martin C; Mahabir, Deepak; Rocke, Brian

    2004-06-16

    We evaluated the reliability and validity of the short form household food security scale in a different setting from the one in which it was developed. The scale was interview administered to 531 subjects from 286 households in north central Trinidad in Trinidad and Tobago, West Indies. We evaluated the six items by fitting item response theory models to estimate item thresholds, estimating agreement among respondents in the same households and estimating the slope index of income-related inequality (SII) after adjusting for age, sex and ethnicity. Item-score correlations ranged from 0.52 to 0.79 and Cronbach's alpha was 0.87. Item responses gave within-household correlation coefficients ranging from 0.70 to 0.78. Estimated item thresholds (standard errors) from the Rasch model ranged from -2.027 (0.063) for the 'balanced meal' item to 2.251 (0.116) for the 'hungry' item. The 'balanced meal' item had the lowest threshold in each ethnic group even though there was evidence of differential functioning for this item by ethnicity. Relative thresholds of other items were generally consistent with US data. Estimation of the SII, comparing those at the bottom with those at the top of the income scale, gave relative odds for an affirmative response of 3.77 (95% confidence interval 1.40 to 10.2) for the lowest severity item, and 20.8 (2.67 to 162.5) for highest severity item. Food insecurity was associated with reduced consumption of green vegetables after additionally adjusting for income and education (0.52, 0.28 to 0.96). The household food security scale gives reliable and valid responses in this setting. Differing relative item thresholds compared with US data do not require alteration to the cut-points for classification of 'food insecurity without hunger' or 'food insecurity with hunger'. The data provide further evidence that re-evaluation of the 'balanced meal' item is required.

  13. Stimulated emission and optical properties of pyranyliden fragment containing compounds in PVK matrix

    NASA Astrophysics Data System (ADS)

    Vembris, Aivars; Zarins, Elmars; Kokars, Valdis

    2017-10-01

    Organic solid state lasers are thoughtfully investigated due to their potential applications in communication, sensors, biomedicine, etc. Low amplified spontaneous emission (ASE) excitation threshold value is essential for further use of the material in devices. Intramolecular interaction limits high molecule density load in the matrix. It is the case of the well-known red light emitting laser dye - 4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran (DCM). The lowest ASE threshold value of the mentioned laser dye could be obtained within the concentration range between 2 and 4 wt%. At higher concentration threshold energy drastically increases. In this work optical and ASE properties of three original DCM derivatives in poly(N-vinylcarbazole) (PVK) at various concentrations will be discussed. One of the derivatives is modified DCM dye in which the methyl substituents in the electron donor part have been replaced with bulky trityloxyethyl groups (DWK-1). These sterically significant functional groups do not influence electron transitions in the dye but prevent aggregation of the molecules. The chemical structure of the second investigated compound is similar to DWK-1 where the methyl group is replaced with the tert-butyl substituent (DWK-1TB). The third derivative (DWK-2) consists of two N,N-di(trityloxyethyl)amino electron donor groups. All results were compared with DCM:PVK system. Photoluminescence quantum yield (PLQY) is up to ten times larger for DWK-1TB with respect to DCM systems. Bulky trityloxyethyl groups prevent aggregation of the molecules thus decreasing interaction between dyes and amount of non-radiative decays. The red shift of the photoluminescence and amplified spontaneous emission at higher concentrations were observed due to the solid state solvation effect. The increase of the investigated dye density in the matrix with a smaller reduction in PLQY resulted in low ASE threshold energy. The lowest threshold value was obtained around 21 μJ/cm2 (2.1 kW/cm2) in DWK-1TB:PVK films.

  14. Evaluation of three different histamine concentrations in intradermal testing of normal cats and attempted determination of 'irritant' threshold concentrations for 48 allergens.

    PubMed

    Austel, Michaela; Hensel, Patrick; Jackson, Dawn; Vidyashankar, Anand; Zhao, Ying; Medleau, Linda

    2006-06-01

    The purpose of this study was to determine the optimal histamine concentration and 'irritant' allergen threshold concentrations in intradermal testing (IDT) in normal cats. Thirty healthy cats were tested with three different histamine concentrations and four different concentrations of each allergen. The optimal histamine concentration was determined to be 1: 50,000 w/v (0.05 mg mL(-1)). Using this histamine concentration, the 'irritant' threshold concentration for most allergens was above the highest concentrations tested (4,000 PNU mL(-1) for 41 allergens and 700 PNU mL(-1) for human dander). The 'irritant' threshold concentration for flea antigen was determined to be 1:750 w/v. More than 10% of the tested cats showed positive reactions to Dermatophagoides farinae, Dermatophagoides pteronyssinus, housefly, mosquito and moth at every allergen concentration, which suggests that the 'irritant' threshold concentration for these allergens is below 1,000 PNU mL(-1), the lowest allergen concentration tested. Our results confirm previous studies in indicating that allergen and histamine concentrations used in feline IDT may need to be revised.

  15. Full control of the spin-wave damping in a magnetic insulator using spin orbit torque

    NASA Astrophysics Data System (ADS)

    Klein, Olivier

    2015-03-01

    The spin-orbit interaction (SOI) has been an interesting and useful addition in the field of spintronics by opening it to non-metallic magnet. It capitalizes on adjoining a strong SOI normal metal next to a thin magnetic layer. The SOI converts a charge current, Jc, into a spin current, Js, with an efficiency parametrized by ΘSH, the spin Hall angle. An important benefit of the SOI is that Jc and Js are linked through a cross-product, allowing a charge current flowing in-plane to produce a spin current flowing out-of-plane. Hence it enables the transfer of spin angular momentum to non-metallic materials and in particular to insulating oxides, which offer improved performance compared to their metallic counterparts. Among all oxides, Yttrium Iron Garnet (YIG) holds a special place for having the lowest known spin-wave (SW) damping factor. Until recently the transmission of spin current through the YIG|Pt interface has been subject to debate. While numerous experiments have reported that Js produced by the excitation of ferromagnetic resonance (FMR) in YIG can cross efficiently the YIG|Pt interface and be converted into Jc in Pt through the inverse spin Hall effect (ISHE), most attempts to observe the reciprocal effect, where Js produced in Pt by the direct spin Hall effect (SHE) is transferred to YIG, resulting in damping compensation, have failed. This has been raising fundamental questions about the reciprocity of the spin transparency of the interface between a metal and a magnetic insulator. In this talk it will be demonstrated that the threshold current for damping compensation can be reached in a 5 μm diameter YIG(20nm)|Pt(7nm) disk. Reduction of both the thickness and lateral size of a YIG-structure were key to reach the microwave generation threshold current, Jc*. The experimental evidence rests upon the measurement of the ferromagnetic resonance linewidth as a function of Idc using a magnetic resonance force microscope (MRFM). It is shwon that the magnetic losses of spin-wave modes existing in the magnetic insulator can be reduced or enhanced by at least a factor of five depending on the polarity and intensity of the in-plane dc current, Idc. Complete compensation of the damping of the fundamental mode by spin-orbit torque is reached for a current density of ~ 3 .1011 A.m-2, in agreement with theoretical predictions. At this critical threshold the MRFM detects a small change of static magnetization, a behavior consistent with the onset of an auto-oscillation regime. This result opens up a new area of research on the electronic control of the damping of YIG-nanostructures.

  16. Barn owls have ageless ears.

    PubMed

    Krumm, Bianca; Klump, Georg; Köppl, Christine; Langemann, Ulrike

    2017-09-27

    We measured the auditory sensitivity of the barn owl ( Tyto alba ), using a behavioural Go/NoGo paradigm in two different age groups, one younger than 2 years ( n = 4) and another more than 13 years of age ( n = 3). In addition, we obtained thresholds from one individual aged 23 years, three times during its lifetime. For computing audiograms, we presented test frequencies of between 0.5 and 12 kHz, covering the hearing range of the barn owl. Average thresholds in quiet were below 0 dB sound pressure level (SPL) for frequencies between 1 and 10 kHz. The lowest mean threshold was -12.6 dB SPL at 8 kHz. Thresholds were the highest at 12 kHz, with a mean of 31.7 dB SPL. Test frequency had a significant effect on auditory threshold but age group had no significant effect. There was no significant interaction between age group and test frequency. Repeated threshold estimates over 21 years from a single individual showed only a slight increase in thresholds. We discuss the auditory sensitivity of barn owls with respect to other species and suggest that birds, which generally show a remarkable capacity for regeneration of hair cells in the basilar papilla, are naturally protected from presbycusis. © 2017 The Author(s).

  17. Input-output relation and energy efficiency in the neuron with different spike threshold dynamics.

    PubMed

    Yi, Guo-Sheng; Wang, Jiang; Tsang, Kai-Ming; Wei, Xi-Le; Deng, Bin

    2015-01-01

    Neuron encodes and transmits information through generating sequences of output spikes, which is a high energy-consuming process. The spike is initiated when membrane depolarization reaches a threshold voltage. In many neurons, threshold is dynamic and depends on the rate of membrane depolarization (dV/dt) preceding a spike. Identifying the metabolic energy involved in neural coding and their relationship to threshold dynamic is critical to understanding neuronal function and evolution. Here, we use a modified Morris-Lecar model to investigate neuronal input-output property and energy efficiency associated with different spike threshold dynamics. We find that the neurons with dynamic threshold sensitive to dV/dt generate discontinuous frequency-current curve and type II phase response curve (PRC) through Hopf bifurcation, and weak noise could prohibit spiking when bifurcation just occurs. The threshold that is insensitive to dV/dt, instead, results in a continuous frequency-current curve, a type I PRC and a saddle-node on invariant circle bifurcation, and simultaneously weak noise cannot inhibit spiking. It is also shown that the bifurcation, frequency-current curve and PRC type associated with different threshold dynamics arise from the distinct subthreshold interactions of membrane currents. Further, we observe that the energy consumption of the neuron is related to its firing characteristics. The depolarization of spike threshold improves neuronal energy efficiency by reducing the overlap of Na(+) and K(+) currents during an action potential. The high energy efficiency is achieved at more depolarized spike threshold and high stimulus current. These results provide a fundamental biophysical connection that links spike threshold dynamics, input-output relation, energetics and spike initiation, which could contribute to uncover neural encoding mechanism.

  18. Input-output relation and energy efficiency in the neuron with different spike threshold dynamics

    PubMed Central

    Yi, Guo-Sheng; Wang, Jiang; Tsang, Kai-Ming; Wei, Xi-Le; Deng, Bin

    2015-01-01

    Neuron encodes and transmits information through generating sequences of output spikes, which is a high energy-consuming process. The spike is initiated when membrane depolarization reaches a threshold voltage. In many neurons, threshold is dynamic and depends on the rate of membrane depolarization (dV/dt) preceding a spike. Identifying the metabolic energy involved in neural coding and their relationship to threshold dynamic is critical to understanding neuronal function and evolution. Here, we use a modified Morris-Lecar model to investigate neuronal input-output property and energy efficiency associated with different spike threshold dynamics. We find that the neurons with dynamic threshold sensitive to dV/dt generate discontinuous frequency-current curve and type II phase response curve (PRC) through Hopf bifurcation, and weak noise could prohibit spiking when bifurcation just occurs. The threshold that is insensitive to dV/dt, instead, results in a continuous frequency-current curve, a type I PRC and a saddle-node on invariant circle bifurcation, and simultaneously weak noise cannot inhibit spiking. It is also shown that the bifurcation, frequency-current curve and PRC type associated with different threshold dynamics arise from the distinct subthreshold interactions of membrane currents. Further, we observe that the energy consumption of the neuron is related to its firing characteristics. The depolarization of spike threshold improves neuronal energy efficiency by reducing the overlap of Na+ and K+ currents during an action potential. The high energy efficiency is achieved at more depolarized spike threshold and high stimulus current. These results provide a fundamental biophysical connection that links spike threshold dynamics, input-output relation, energetics and spike initiation, which could contribute to uncover neural encoding mechanism. PMID:26074810

  19. Identifying cochlear implant channels with poor electrode-neuron interface: electrically-evoked auditory brainstem responses measured with the partial tripolar configuration

    PubMed Central

    Bierer, Julie Arenberg; Faulkner, Kathleen F.; Tremblay, Kelly L.

    2011-01-01

    Objectives The goal of this study was to compare cochlear implant behavioral measures and electrically-evoked auditory brainstem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves (Bierer and Faulkner, 2010). The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, such as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping procedure, especially for young children. Here we have extended the previous investigation to determine if a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. Design Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ=1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ=0) and a more focused partial tripolar (σ ≥ 0.50) configuration. Results Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds obtained with both the monopolar and partial tripolar configurations. The Wave V amplitude growth functions with increasing stimulus level showed the predicted effect of shallower growth for the partial tripolar than for the monopolar configuration, but this was observed only for the low threshold channel. In contrast, high-threshold channels showed the opposite effect; steeper growth functions were seen for the partial tripolar configuration. Conclusions These results suggest that behavioral thresholds or EABRs measured with a restricted stimulus can be used to identify potentially impaired cochlear implant channels. Channels having high thresholds and steep growth functions would likely not activate the appropriate spatially restricted region of the cochlea, leading to suboptimal perception. As a clinical tool, quick identification of impaired channels could lead to patient-specific mapping strategies and result in improved speech and music perception. PMID:21178633

  20. Implications of climate change on winter road networks in Ontario's Far North and northern Manitoba, Canada, based on climate model projections

    NASA Astrophysics Data System (ADS)

    Hori, Y.; Cheng, V. Y. S.; Gough, W. A.

    2017-12-01

    A network of winter roads in northern Canada connects a number of remote First Nations communities to all-season roads and rails. The extent of the winter road networks depends on the geographic features, socio-economic activities, and the numbers of remote First Nations so that it differs among the provinces. The most extensive winter road networks below the 60th parallel south are located in Ontario and Manitoba, serving 32 and 18 communities respectively. In recent years, a warmer climate has resulted in a shorter winter road season and an increase in unreliable road conditions; thus, limiting access among remote communities. This study focused on examining the future freezing degree-days (FDDs) accumulations during the winter road season at selected locations throughout Ontario's Far North and northern Manitoba using recent climate model projections from the multi-model ensembles of General Circulation Models (GCMs) under the Representative Concentration Pathway (RCP) scenarios. First, the non-parametric Mann-Kendall correlation test and the Theil-Sen method were used to identify any statistically significant trends between FDDs and time for the base period (1981-2010). Second, future climate scenarios are developed for the study areas using statistical downscaling methods. This study also examined the lowest threshold of FDDs during the winter road construction in a future period. Our previous study established the lowest threshold of 380 FDDs, which derived from the relationship between the FDDs and the opening dates of James Bay Winter Road near the Hudson-James Bay coast. Thus, this study applied the threshold measure as a conservative estimate of the minimum threshold of FDDs to examine the effects of climate change on the winter road construction period.

  1. A low dose of three local anesthetic solutions for interscalene blockade tested by thermal quantitative sensory testing: a randomized controlled trial.

    PubMed

    Sermeus, Luc A; Schepens, Tom; Hans, Guy H; Morrison, Stuart G; Wouters, Kristien; Breebaart, Margaretha B; Smitz, Carine J; Vercauteren, Marcel P

    2018-05-03

    This randomized double-blind controlled trial compared the block characteristics of three low-dose local anesthetics at different roots in an ultrasound-guided interscalene block, using thermal quantitative sensory testing for assessing the functioning of cutaneous small nerve fibres. A total of 37 adults scheduled to undergo shoulder arthroscopy were randomized to receive 5 mL of either 0.5% levobupivacaine with and without epinephrine 1/200,000 or 0.75% ropivacaine in a single-shot interscalene block. Thermal quantitative sensory testing was performed in the C4, C5, C6 and C7 dermatomes. Detection thresholds for cold/warm sensation and cold/heat pain were measured before and at 30 min, 6, 10 and 24 h after infiltration around C5. The need for rescue medication was recorded. No significant differences between groups were found for any sensation (lowest P = 0.28). At 6 h, the largest differences in sensory thresholds were observed for the C5 dermatome. The increase in thresholds were less in C4 and C6 and minimal in C7 for all sensations. The analgesic effect lasted the longest in C5 (time × location mixed model P < 0.001 for all sensory tests). The time to rescue analgesia was significantly shorter with 0.75% ropivacaine (P = 0.02). The quantitative sensory findings showed no difference in intensity between the local anesthetics tested. A decrease in block intensity, with minimal changes in pain detection thresholds, was observed in the roots adjacent to C5, with the lowest block intensity in C7. A clinically relevant shorter duration was found with 0.75% ropivacaine compared to the other groups. Trial registration NCT 02691442.

  2. Semiconductor diode laser material and devices with emission in visible region of the spectrum

    NASA Technical Reports Server (NTRS)

    Ladany, I.; Kressel, H.

    1975-01-01

    Two alloy systems, (AlGa)As and (InGa)P, were studied for their properties relevant to obtaining laser diode operation in the visible region of the spectrum. (AlGa)As was prepared by liquid-phase epitaxy (LPE) and (InGa)P was prepared both by vapor-phase epitaxy and by liquid-phase epitaxy. Various schemes for LPE growth were applied to (InGa)P, one of which was found to be capable of producing device material. All the InGaP device work was done using vapor-phase epitaxy. The most successful devices were fabricated in (AlGa)As using heterojunction structures. At room temperature, the large optical cavity design yielded devices lasing in the red (7000 A). Because of the relatively high threshold due to the basic band structure limitation in this alloy, practical laser diode operation is presently limited to about 7300 A. At liquid-nitrogen temperature, practical continuous-wave operation was obtained at a wavelength of 6500 to 6600 A, with power emission in excess of 50 mW. The lowest pulsed lasing wavelength is 6280 A. At 223 K, lasing was obtained at 6770 A, but with high threshold currents. The work dealing with CW operation at room temperature was successful with practical operation having been achieved to about 7800 A.

  3. Ethanol catalytic optical driven deposition for 1D and 2D materials with ultra-low power threshold of 0 dBm

    NASA Astrophysics Data System (ADS)

    Wang, Hao; Chen, Bohua; Xiao, Xu; Guo, Chaoshi; Zhang, Xiaoyan; Wang, Jun; Jiang, Meng; Wu, Kan; Chen, Jianping

    2018-01-01

    We have demonstrated a generalized optical driven deposition method, ethanol catalytic deposition (ECD) method, which is widely applicable to the deposition of a broad range of one-dimensional (1D) and two-dimensional (2D) materials with common deposition parameters. Using ECD method, deposition of 1D material carbon nanotubes and 2D materials MoS2, MoSe2, WS2 and WSe2 on tapered fiber has been demonstrated with the threshold power as low as 0 dBm. To our knowledge, this is the lowest threshold power ever reported in optical driven deposition, noting that the conventional optical driven deposition has a threshold typically near 15 dBm. It means ECD method can significantly reduce the power requirement and simplify the setup of the optical driven deposition as well as its wide applicability to different materials, which benefits the research on optical nonlinearity and ultrafast photonics of 1D and 2D materials.

  4. Systematic study of the effects of stimulus parameters and stimulus location on afterdischarges elicited by electrical stimulation in the rat.

    PubMed

    Shigeto, Hiroshi; Boongird, Atthaporn; Baker, Kenneth; Kellinghaus, Christoph; Najm, Imad; Lüders, Hans

    2013-03-01

    Electrical brain stimulation is used in a variety of clinical situations, including cortical mapping for epilepsy surgery, cortical stimulation therapy to terminate seizure activity in the cortex, and in deep brain stimulation therapy. However, the effects of stimulus parameters are not fully understood. In this study, we systematically tested the impact of various stimulation parameters on the generation of motor symptoms and afterdischarges (ADs). Focal electrical stimulation was delivered at subdural cortical, intracortical, and hippocampal sites in a rat model. The effects of stimulus parameter on the generation of motor symptoms and on the occurrence of ADs were examined. The effect of stimulus irregularity was tested using random or regular 50Hz stimulation through subdural electrodes. Hippocampal stimulation produced ADs at lower thresholds than neocortical stimulation. Hippocampal stimulation also produced significantly longer ADs. Both in hippocampal and cortical stimulation, when the total current was kept constant with changing pulse width, the threshold for motor symptom or AD was lowest between 50 and 100Hz and higher at both low and high frequencies. However, if the pulse width was fixed, the threshold did not increase above 100Hz and it apparently continued to decrease through 800Hz even if the difference did not reach statistical significance. There was no significant difference between random and regular stimulation. Overall, these results indicate that electrode location and several stimulus parameters including frequency, pulse width, and total electricity are important in electrical stimulation to produce motor symptoms and ADs. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Hydrodynamic sensory threshold in harbour seals (Phoca vitulina) for artificial flatfish breathing currents.

    PubMed

    Niesterok, Benedikt; Dehnhardt, Guido; Hanke, Wolf

    2017-07-01

    Harbour seals have the ability to detect benthic fish such as flatfish using the water currents these fish emit through their gills (breathing currents). We investigated the sensory threshold in harbour seals for this specific hydrodynamic stimulus under conditions which are realistic for seals hunting in the wild. We used an experimental platform where an artificial breathing current was emitted through one of eight different nozzles. Two seals were trained to search for the active nozzle. Each experimental session consisted of eight test trials of a particular stimulus intensity and 16 supra-threshold trials of high stimulus intensity. Test trials were conducted with the animals blindfolded. To determine the threshold, a series of breathing currents differing in intensity was used. For each intensity, three sessions were run. The threshold in terms of maximum water velocity within the breathing current was 4.2 cm s -1 for one seal and 3.7 cm s -1 for the other. We measured background flow velocities from 1.8 to 3.4 cm s -1 Typical swimming speeds for both animals were around 0.5 m s -1 Swimming speed differed between successful and unsuccessful trials. It appears that swimming speed is restricted for the successful detection of a breathing current close to the threshold. Our study is the first to assess a sensory threshold of the vibrissal system for a moving harbour seal under near-natural conditions. Furthermore, this threshold was defined for a natural type of stimulus differing from classical dipole stimuli which have been widely used in threshold determination so far. © 2017. Published by The Company of Biologists Ltd.

  6. Cochlear's unique electrode portfolio now and in the future.

    PubMed

    von Wallenberg, E; Briggs, R

    2014-05-01

    To review Cochlear's electrode portfolio and discuss the merits of current and future straight and perimodiolar electrode arrays. To present an update on implant reliability. Performance and hearing preservation data from studies involving the Slim Straight (CI422), Hybrid L24 and Contour Advance electrode array were reviewed. While several studies in past found little difference in performance outcomes between subjects implanted with perimodiolar and straight arrays, recent studies demonstrated that proximity to the modiolus is correlated with better performance. Hearing threshold increase was lowest with the Hybrid L24, closely followed by the slim straight array and was largest with the Contour Advance array. The CI24RE receiver-stimulator used for the three arrays had a cumulative survival of 99% at eight years post implantation. Combining the hearing preservation benefits of slim straight arrays with perimodiolar proximity is the design objective of Cochlear's next generation electrodes.

  7. First measurement of the beam asymmetry in photoproduction off the proton near threshold

    NASA Astrophysics Data System (ADS)

    Levi Sandri, P.; Mandaglio, G.; De Leo, V.; Bartalini, O.; Bellini, V.; Bocquet, J.-P.; Capogni, M.; Curciarello, F.; Didelez, J.-P.; D'Angelo, A.; Di Salvo, R.; Fantini, A.; Franco, D.; Gervino, G.; Ghio, F.; Girolami, B.; Giusa, A.; Lapik, A.; Lleres, A.; Mammoliti, F.; Manganaro, M.; Moricciani, D.; Mushkarenkov, A.; Nedorezov, V.; Randieri, C.; Rebreyend, D.; Rudnev, N.; Russo, G.; Schaerf, C.; Sperduto, M.-L.; Sutera, M.-C.; Turinge, A.; Vegna, V.; Zonta, I.

    2015-07-01

    The beam asymmetry in photoproduction off the proton was measured at the GrAAL polarised photon beam with incoming photon energies of 1.461 and 1.480 GeV. For both energies the asymmetry as a function of the meson production angle shows a clear structure, more pronounced at the lowest one, with a change of sign around . The observed behaviour is compatible with P-wave D-wave (or S-wave F-wave) interference, the closer to threshold the stronger. The results are compared to the existing state-of-the-art calculations that fail to account for the data.

  8. Monitoring training response in young Friesian dressage horses using two different standardised exercise tests (SETs).

    PubMed

    de Bruijn, Cornelis Marinus; Houterman, Willem; Ploeg, Margreet; Ducro, Bart; Boshuizen, Berit; Goethals, Klaartje; Verdegaal, Elisabeth-Lidwien; Delesalle, Catherine

    2017-02-14

    Most Friesian horses reach their anaerobic threshold during a standardized exercise test (SET) which requires lower intensity exercise than daily routine training. to study strengths and weaknesses of an alternative SET-protocol. Two different SETs (SETA and SETB) were applied during a 2 month training period of 9 young Friesian dressage horses. SETB alternated short episodes of canter with trot and walk, lacking long episodes of cantering, as applied in SETA. Following parameters were monitored: blood lactic acid (BLA) after cantering, average heart rate (HR) in trot and maximum HR in canter. HR and BLA of SETA and SETB were analyzed using a paired two-sided T-test and Spearman Correlation-coefficient (p* < 0.05). BLA after cantering was significantly higher in SETA compared to SETB and maximum HR in canter was significantly higher in SETA compared to SETB. The majority of horses showed a significant training response based upon longitudinal follow-up of BLA. Horses with the lowest fitness at start, displayed the largest training response. BLA was significantly lower in week 8 compared to week 0, in both SETA and SETB. A significantly decreased BLA level after cantering was noticeable in week 6 in SETA, whereas in SETB only as of week 8. In SETA a very strong correlation for BLA and average HR at trot was found throughout the entire training period, not for canter. Young Friesian horses do reach their anaerobic threshold during a SET which requires lower intensity than daily routine training. Therefore close monitoring throughout training is warranted. Longitudinal follow up of BLA and not of HR is suitable to assess training response. In the current study, horses that started with the lowest fitness level, showed the largest training response. During training monitoring HR in trot rather than in canter is advised. SETB is best suited as a template for daily training in the aerobic window.

  9. Correlations among within-channel and between-channel auditory gap-detection thresholds in normal listeners.

    PubMed

    Phillips, Dennis P; Smith, Jennifer C

    2004-01-01

    We obtained data on within-channel and between-channel auditory temporal gap-detection acuity in the normal population. Ninety-five normal listeners were tested for gap-detection thresholds, for conditions in which the gap was bounded by spectrally identical, and by spectrally different, acoustic markers. Separate thresholds were obtained with the use of an adaptive tracking method, for gaps delimited by narrowband noise bursts centred on 1.0 kHz, noise bursts centred on 4.0 kHz, and for gaps bounded by a leading marker of 4.0 kHz noise and a trailing marker of 1.0 kHz noise. Gap thresholds were lowest for silent periods bounded by identical markers--'within-channel' stimuli. Gap thresholds were significantly longer for the between-channel stimulus--silent periods bounded by unidentical markers (p < 0.0001). Thresholds for the two within-channel tasks were highly correlated (R = 0.76). Thresholds for the between-channel stimulus were weakly correlated with thresholds for the within-channel stimuli (1.0 kHz, R = 0.39; and 4.0 kHz, R = 0.46). The relatively poor predictability of between-channel thresholds from the within-channel thresholds is new evidence on the separability of the mechanisms that mediate performance of the two tasks. The data confirm that the acuity difference for the tasks, which has previously been demonstrated in only small numbers of highly trained listeners, extends to a population of untrained listeners. The acuity of the between-channel mechanism may be relevant to the formation of voice-onset time-category boundaries in speech perception.

  10. Biophysical mechanism of spike threshold dependence on the rate of rise of the membrane potential by sodium channel inactivation or subthreshold axonal potassium current

    PubMed Central

    Wester, Jason C.

    2013-01-01

    Spike threshold filters incoming inputs and thus gates activity flow through neuronal networks. Threshold is variable, and in many types of neurons there is a relationship between the threshold voltage and the rate of rise of the membrane potential (dVm/dt) leading to the spike. In primary sensory cortex this relationship enhances the sensitivity of neurons to a particular stimulus feature. While Na+ channel inactivation may contribute to this relationship, recent evidence indicates that K+ currents located in the spike initiation zone are crucial. Here we used a simple Hodgkin-Huxley biophysical model to systematically investigate the role of K+ and Na+ current parameters (activation voltages and kinetics) in regulating spike threshold as a function of dVm/dt. Threshold was determined empirically and not estimated from the shape of the Vm prior to a spike. This allowed us to investigate intrinsic currents and values of gating variables at the precise voltage threshold. We found that Na+ inactivation is sufficient to produce the relationship provided it occurs at hyperpolarized voltages combined with slow kinetics. Alternatively, hyperpolarization of the K+ current activation voltage, even in the absence of Na+ inactivation, is also sufficient to produce the relationship. This hyperpolarized shift of K+ activation allows an outward current prior to spike initiation to antagonize the Na+ inward current such that it becomes self-sustaining at a more depolarized voltage. Our simulations demonstrate parameter constraints on Na+ inactivation and the biophysical mechanism by which an outward current regulates spike threshold as a function of dVm/dt. PMID:23344915

  11. Very low threshold-current temperature sensitivity in constricted double-heterojunction AlGaAs lasers

    NASA Technical Reports Server (NTRS)

    Botez, D.; Connolly, J. C.; Gilbert, D. B.; Ettenberg, M.

    1981-01-01

    The temperature dependence of threshold currents in constricted double-heterojunction diode lasers with strong lateral mode confinement is found to be significantly milder than for other types of lasers. The threshold-current relative variations with ambient temperature are typically two to three times less than for other devices of CW-operation capability. Over the interval 10-70 C the threshold currents fit the empirical exponential law exp/(T2-T1)/T0/ with T0 values in the 240-375 C range in pulsed operation, and in the 200-310 C range in CW operation. The external differential quantum efficiency and the mode far-field pattern near threshold are virtually invariant with temperature. The possible causes of high-T0 behavior are analyzed, and a new phenomenon - temperature-dependent current focusing - is presented to explain the results.

  12. Repeated restraint stress lowers the threshold for response to third ventricle CRF administration.

    PubMed

    Harris, Ruth B S

    2017-03-01

    Rats and mice exposed to repeated stress or a single severe stress exhibit a sustained increase in energetic, endocrine, and behavioral response to subsequent novel mild stress. This study tested whether the hyper-responsiveness was due to a lowered threshold of response to corticotropin releasing factor (CRF) or an exaggerated response to a standard dose of CRF. Male Sprague-Dawley rats were subjected to 3h of restraint on each of 3 consecutive days (RRS) or were non-restrained controls. RRS caused a temporary hypophagia but a sustained reduction in body weight. Eight days after the end of restraint, rats received increasing third ventricle doses of CRF (0-3.0μg). The lowest dose of CRF (0.25μg) increased corticosterone release in RRS, but not control rats. Higher doses caused the same stimulation of corticosterone in the two groups of rats. Fifteen days after the end of restraint, rats were food deprived during the light period and received increasing third ventricle doses of CRF at the start of the dark period. The lowest dose of CRF inhibited food intake during the first hour following infusion in RRS, but not control rats. All other doses of CRF inhibited food intake to the same degree in both RRS and control rats. The lowered threshold of response to central CRF is consistent with the chronic hyper-responsiveness to CRF and mild stress in RRS rats during the post-restraint period. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Patterns of motor recruitment can be determined using surface EMG.

    PubMed

    Wakeling, James M

    2009-04-01

    Previous studies have reported how different populations of motor units (MUs) can be recruited during dynamic and locomotor tasks. It was hypothesised that the higher-threshold units would contribute higher-frequency components to the sEMG spectra due to their faster conduction velocities, and thus recruitment patterns that increase the proportion of high-threshold units active would lead to higher-frequency elements in the sEMG spectra. This idea was tested by using a model of varying recruitment coupled to a three-layer volume conductor model to generate a series of sEMG signals. The recruitment varied from (A) orderly recruitment where the lowest-threshold MUs were initially activated and higher-threshold MUs were sequentially recruited as the contraction progressed, (B) a recurrent inhibition model that started with orderly recruitment, but as the higher-threshold units were activated they inhibited the lower-threshold MUs (C) nine models with intermediate properties that were graded between these two extremes. The sEMG was processed using wavelet analysis and the spectral properties quantified by their mean frequency, and an angle theta that was determined from the principal components of the spectra. Recruitment strategies that resulted in a greater proportion of faster MUs being active had a significantly lower theta and higher mean frequency.

  14. Auditory Brainstem Response Thresholds to Air- and Bone-Conducted CE-Chirps in Neonates and Adults.

    PubMed

    Cobb, Kensi M; Stuart, Andrew

    2016-08-01

    The purpose of this study was to compare auditory brainstem response (ABR) thresholds to air- and bone-conducted CE-Chirps in neonates and adults. Thirty-two neonates with no physical or neurologic challenges and 20 adults with normal hearing participated. ABRs were acquired with a starting intensity of 30 dB normal hearing level (nHL). The lowest stimulus intensity level at which a wave V was identifiable and replicable was considered the ABR threshold. ABR thresholds to air-conducted CE-Chirps were 9.8 dB nHL for neonates and adults. ABR thresholds to bone-conducted CE-Chirps were 3.8 and 13.8 dB nHL for neonates and adults, respectively. The difference in ABR thresholds to bone-conducted CE-Chirps was significantly different (p < .0001, ηp2 = .45). Adults had significantly larger wave V amplitudes to air- (p < .0001, ηp2 = .50) and bone-conducted (p = .013, ηp2 = .15) CE-Chirps at a stimulus intensity of 30 dB nHL. At the same intensity, adults evidenced significantly shorter wave V latencies (p < .0001, ηp2 = .49) only with air-conducted CE-chirps. The difference in ABR thresholds and wave V latencies to air- and bone-conducted CE-Chirps between neonates and adults may be attributed to a disparity in effective signal delivery to the cochlea.

  15. Influence of emission threshold of explosive emission cathodes on current waveform in foilless diodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, P.; Liu, G. Z.; Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi'an 710024

    The emission threshold of explosive emission cathodes (EECs) is an important factor for beam quality. It can affect the explosive emission delay time, the plasma expansion process on the cathode surface, and even the current amplitude when the current is not fully space-charge-limited. This paper researches the influence of the emission threshold of an annular EEC on the current waveform in a foilless diode when the current is measured by a Rogowski coil. The particle-in-cell simulation which is performed under some tolerable and necessary simplifications shows that the long explosive emission delay time of high-threshold cathodes may leave an apparentmore » peak of displacement current on the rise edge of the current waveform, and this will occur only when the electron emission starts after this peak. The experimental researches, which are performed under a diode voltage of 1 MV and a repetitive frequency of 20 Hz, demonstrate that the graphite cathode has a lower emission threshold and a longer lifetime than the stainless steel cathode according to the variation of the peak of displacement current on the rise edge of the current waveform.« less

  16. Temperature dependence of threshold current in GaAs/AlGaAs quantum well lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blood, P.; Colak, S.; Kucharska, A.I.

    1988-02-22

    We have calculated the threshold current and its temperature (T) dependence in the range 200--400 K for AlGaAs quantum well lasers with 25-A-wide GaAs wells using a model which includes lifetime broadening of the transitions and broadening of the density of states function by fluctuations in the well width. The threshold current varies approximately linearly with T and the principal effect of broadening is to increase the threshold current causing a reduction in the fractional change of current with temperature. The apparent value of the parameter T/sub 0/ is increased to approx. =400 K, compared with approx. =320 K withoutmore » broadening. The calculations are compared with experimental data.« less

  17. The influence of stripe width on the threshold current of double-heterojunction lasers

    NASA Technical Reports Server (NTRS)

    Ladany, I.

    1977-01-01

    Experimental measurements of the threshold current of oxide-isolated stripe laser as a function of stripe width and p-layer resistivity are presented. A calculation of the influence of carrier outdiffusion has been made, including the effect of current leakage beyond the stripe edges. The calculated threshold increase is in substantial agreement with experiment for stripe widths down to about 10 microns. The data also yield an effective diffusion length of about 7 microns for the lasers studied. Deviations between experimental and calculated thresholds occurring at stripe widths of 4-6 microns are represented by an empirical curve which is compared with previously published calculations of threshold gain.

  18. Ultralow percolation threshold of single walled carbon nanotube-epoxy composites synthesized via an ionic liquid dispersant/initiator

    NASA Astrophysics Data System (ADS)

    Watters, Arianna L.; Palmese, Giuseppe R.

    2014-09-01

    Uniform dispersion of single walled carbon nanotubes (SWNTs) in an epoxy was achieved by a streamlined mechano-chemical processing method. SWNT-epoxy composites were synthesized using a room temperature ionic liquid (IL) with an imidazolium cation and dicyanamide anion. The novel approach of using ionic liquid that behaves as a dispersant for SWNTs and initiator for epoxy polymerization greatly simplifies nanocomposite synthesis. The material was processed using simple and scalable three roll milling. The SWNT dispersion of the resultant composite was evaluated by electron microscopy and electrical conductivity measurements in conjunction with percolation theory. Processing conditions were optimized to achieve the lowest possible percolation threshold, 4.29 × 10-5 volume fraction SWNTs. This percolation threshold is among the best reported in literature yet it was obtained using a streamlined method that greatly simplifies processing.

  19. Impact response of graphite-epoxy flat laminates using projectiles that simulate aircraft engine encounters

    NASA Technical Reports Server (NTRS)

    Preston, J. L., Jr.; Cook, T. S.

    1975-01-01

    An investigation of the response of a graphite-epoxy material to foreign object impact was made by impacting spherical projectiles of gelatin, ice, and steel normally on flat panels. The observed damage was classified as transverse (stress wave delamination and cracking), penetrative, or structural (gross failure): the minimum, or threshold, velocity to cause each class of damage was established as a function of projectile characteristics. Steel projectiles had the lowest transverse damage threshold, followed by gelatin and ice. Making use of the threshold velocities and assuming that the normal component of velocity produces the damage in nonnormal impacts, a set of impact angles and velocities was established for each projectile material which would result in damage to composite fan blades. Analysis of the operating parameters of a typical turbine fan blade shows that small steel projectiles are most likely to cause delamination and penetration damage to unprotected graphite-epoxy composite fan blades.

  20. The low threshold voltage n-type silicon transistors based on a polymer/silica nanocomposite gate dielectric: The effect of annealing temperatures on their operation

    NASA Astrophysics Data System (ADS)

    Hashemi, Adeleh; Bahari, Ali; Ghasemi, Shahram

    2017-09-01

    In this work, povidone/silica nanocomposite dielectric layers were deposited on the n-type Si (100) substrates for application in n-type silicon field-effect transistors (FET). Thermogravimetric analysis (TGA) indicated that strong chemical interactions between polymer and silica nanoparticles were created. In order to examine the effect of annealing temperatures on chemical interactions and nanostructure properties, annealing process was done at 423-513 K. Atomic force microscopy (AFM) images show the very smooth surfaces with very low surface roughness (0.038-0.088 nm). The Si2p and C1s core level photoemission spectra were deconvoluted to the chemical environments of Si and C atoms respectively. The obtained results of deconvoluted X-ray photoelectron spectroscopy (XPS) spectra revealed a high percentage of silanol hydrogen bonds in the sample which was not annealed. These bonds were inversed to stronger covalence bonds (siloxan bonds) at annealing temperature of 423 K. By further addition of temperature, siloxan bonds were shifted to lower binding energy of about 1 eV and their intensity were abated at annealing temperature of 513 K. The electrical characteristics were extracted from current-Voltage (I-V) and capacitance-voltage (C-V) measurements in metal-insulator-semiconductor (MIS) structure. The all n-type Si transistors showed very low threshold voltages (-0.24 to 1 V). The formation of the strongest cross-linking at nanostructure of dielectric film annealed at 423 K caused resulted in an un-trapped path for the transport of charge carriers yielding the lowest threshold voltage (0.08 V) and the highest electron mobility (45.01 cm2/V s) for its FET. By increasing the annealing temperature (473 and 513 K) on the nanocomposite dielectric films, the values of the average surface roughness, the capacitance and the FET threshold voltage increased and the value of FET electron field-effect mobility decreased.

  1. Effects of whole body vibration on motor unit recruitment and threshold

    PubMed Central

    Woledge, Roger C.; Martin, Finbarr C.; Newham, Di J.

    2012-01-01

    Whole body vibration (WBV) has been suggested to elicit reflex muscle contractions but this has never been verified. We recorded from 32 single motor units (MU) in the vastus lateralis of 7 healthy subjects (34 ± 15.4 yr) during five 1-min bouts of WBV (30 Hz, 3 mm peak to peak), and the vibration waveform was also recorded. Recruitment thresholds were recorded from 38 MUs before and after WBV. The phase angle distribution of all MUs during WBV was nonuniform (P < 0.001) and displayed a prominent peak phase angle of firing. There was a strong linear relationship (r = −0.68, P < 0.001) between the change in recruitment threshold after WBV and average recruitment threshold; the lowest threshold MUs increased recruitment threshold (P = 0.008) while reductions were observed in the higher threshold units (P = 0.031). We investigated one possible cause of changed thresholds. Presynaptic inhibition in the soleus was measured in 8 healthy subjects (29 ± 4.6 yr). A total of 30 H-reflexes (stimulation intensity 30% Mmax) were recorded before and after WBV: 15 conditioned by prior stimulation (60 ms) of the antagonist and 15 unconditioned. There were no significant changes in the relationship between the conditioned and unconditioned responses. The consistent phase angle at which each MU fired during WBV indicates the presence of reflex muscle activity similar to the tonic vibration reflex. The varying response in high- and low-threshold MUs may be due to the different contributions of the mono- and polysynaptic pathways but not presynaptic inhibition. PMID:22096119

  2. Effects of whole body vibration on motor unit recruitment and threshold.

    PubMed

    Pollock, Ross D; Woledge, Roger C; Martin, Finbarr C; Newham, Di J

    2012-02-01

    Whole body vibration (WBV) has been suggested to elicit reflex muscle contractions but this has never been verified. We recorded from 32 single motor units (MU) in the vastus lateralis of 7 healthy subjects (34 ± 15.4 yr) during five 1-min bouts of WBV (30 Hz, 3 mm peak to peak), and the vibration waveform was also recorded. Recruitment thresholds were recorded from 38 MUs before and after WBV. The phase angle distribution of all MUs during WBV was nonuniform (P < 0.001) and displayed a prominent peak phase angle of firing. There was a strong linear relationship (r = -0.68, P < 0.001) between the change in recruitment threshold after WBV and average recruitment threshold; the lowest threshold MUs increased recruitment threshold (P = 0.008) while reductions were observed in the higher threshold units (P = 0.031). We investigated one possible cause of changed thresholds. Presynaptic inhibition in the soleus was measured in 8 healthy subjects (29 ± 4.6 yr). A total of 30 H-reflexes (stimulation intensity 30% Mmax) were recorded before and after WBV: 15 conditioned by prior stimulation (60 ms) of the antagonist and 15 unconditioned. There were no significant changes in the relationship between the conditioned and unconditioned responses. The consistent phase angle at which each MU fired during WBV indicates the presence of reflex muscle activity similar to the tonic vibration reflex. The varying response in high- and low-threshold MUs may be due to the different contributions of the mono- and polysynaptic pathways but not presynaptic inhibition.

  3. 49 CFR 38.153 - Doors, steps and thresholds.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...)(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to a minimum width of 18 inches (457 mm). The clear width may be reduced by a maximum of 4 inches (100 mm) by protrusions...

  4. 49 CFR 38.153 - Doors, steps and thresholds.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...)(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to a minimum width of 18 inches (457 mm). The clear width may be reduced by a maximum of 4 inches (100 mm) by protrusions...

  5. 36 CFR § 1192.153 - Doors, steps and thresholds.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to a minimum width of 18 inches (457 mm). The clear width may be reduced by a maximum of 4 inches (100 mm) by protrusions of hinges or...

  6. 36 CFR 1192.153 - Doors, steps and thresholds.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to a minimum width of 18 inches (457 mm). The clear width may be reduced by a maximum of 4 inches (100 mm) by protrusions of hinges or other operating...

  7. 49 CFR 38.153 - Doors, steps and thresholds.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...)(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to a minimum width of 18 inches (457 mm). The clear width may be reduced by a maximum of 4 inches (100 mm) by protrusions...

  8. 36 CFR 1192.153 - Doors, steps and thresholds.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to a minimum width of 18 inches (457 mm). The clear width may be reduced by a maximum of 4 inches (100 mm) by protrusions of hinges or other operating...

  9. 36 CFR 1192.153 - Doors, steps and thresholds.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to a minimum width of 18 inches (457 mm). The clear width may be reduced by a maximum of 4 inches (100 mm) by protrusions of hinges or other operating...

  10. 49 CFR 38.153 - Doors, steps and thresholds.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...)(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to a minimum width of 18 inches (457 mm). The clear width may be reduced by a maximum of 4 inches (100 mm) by protrusions...

  11. Combining inferences from models of capture efficiency, detectability, and suitable habitat to classify landscapes for conservation of threatened bull trout

    USGS Publications Warehouse

    Peterson, J.; Dunham, J.B.

    2003-01-01

    Effective conservation efforts for at-risk species require knowledge of the locations of existing populations. Species presence can be estimated directly by conducting field-sampling surveys or alternatively by developing predictive models. Direct surveys can be expensive and inefficient, particularly for rare and difficult-to-sample species, and models of species presence may produce biased predictions. We present a Bayesian approach that combines sampling and model-based inferences for estimating species presence. The accuracy and cost-effectiveness of this approach were compared to those of sampling surveys and predictive models for estimating the presence of the threatened bull trout ( Salvelinus confluentus ) via simulation with existing models and empirical sampling data. Simulations indicated that a sampling-only approach would be the most effective and would result in the lowest presence and absence misclassification error rates for three thresholds of detection probability. When sampling effort was considered, however, the combined approach resulted in the lowest error rates per unit of sampling effort. Hence, lower probability-of-detection thresholds can be specified with the combined approach, resulting in lower misclassification error rates and improved cost-effectiveness.

  12. A Climatology of dust emission in northern Africa using surface observations from 1984-2012

    NASA Astrophysics Data System (ADS)

    Cowie, Sophie; Knippertz, Peter; Marsham, John

    2014-05-01

    The huge quantity of mineral dust emitted annually from northern Africa makes this area crucial to the global dust cycle. Once in the atmosphere, dust aerosols have a significant impact on the global radiation budget, clouds, the carbon cycle and can even act as a fertilizer to rain forests in South America. Current model estimates of dust production from northern Africa are uncertain. At the heart of this problem is insufficient understanding of key dust emitting processes such as haboobs (cold pools generated through evaporation of convective precipitation), low-level jets (LLJs) and dry convection (dust devils and dust plumes). Scarce observations in this region, in particular in the Sahara, make model evaluation difficult. This work uses long-term surface observations from 70 stations situated in the Sahara and Sahel to explore the diurnal, seasonal and geographical variations in dust emission events and thresholds. Quality flags are applied to each station to indicate a day-time bias or gaps in the time period 1984-2012. The frequency of dust emission (FDE) is calculated using the present weather codes (WW) of SYNOP reports, where WW = 07,08,09,30-35 and 98. Thresholds are investigated by estimating the wind speeds for which there is a 25%, 50% and 75% probability of dust emission. The 50% threshold is used to calculate strong wind frequency (SWF) and the diagnostic parameter dust uplift potential (DUP); a thresholded cubic function of wind-speed which quantifies the dust generating power of winds. Stations are grouped into 6 areas (North Algeria, Central Sahara, Egypt, West Sahel, Central Sahel and Sudan) for more in-depth analysis of these parameters. Spatially, thresholds are highest in northern Algeria and lowest in the Sahel around the latitude band 16N-21N. Annual mean FDE is anti-correlated with the threshold, showing the importance of spatial variations in thresholds for mean dust emission. The annual cycles of FDE and SWF for the 6 grouped areas are highly correlated (0.95 to 0.99). These correlations are barely reduced when annual-mean thresholds are used, showing that seasonal variations in thresholds are not the main control on the seasonal variations in FDE. Relationships between annual cycles in FDE and DUP are more complex than between FDE and SWF, reflecting the seasonal variations in the types and intensities of dust events. FDE is highest in spring north of 23N. South of this, where stations are directly influenced by the summer monsoon, the annual cycle in FDE is much more variable. Half of the total DUP occurs at wind-speeds greater than ~ 28 ms-1, which highlights the importance of rare high-energy wind events. The likely meteorological mechanisms generating these patterns are discussed.

  13. Methods of Muscle Activation Onset Timing Recorded During Spinal Manipulation.

    PubMed

    Currie, Stuart J; Myers, Casey A; Krishnamurthy, Ashok; Enebo, Brian A; Davidson, Bradley S

    2016-05-01

    The purpose of this study was to determine electromyographic threshold parameters that most reliably characterize the muscular response to spinal manipulation and compare 2 methods that detect muscle activity onset delay: the double-threshold method and cross-correlation method. Surface and indwelling electromyography were recorded during lumbar side-lying manipulations in 17 asymptomatic participants. Muscle activity onset delays in relation to the thrusting force were compared across methods and muscles using a generalized linear model. The threshold combinations that resulted in the lowest Detection Failures were the "8 SD-0 milliseconds" threshold (Detection Failures = 8) and the "8 SD-10 milliseconds" threshold (Detection Failures = 9). The average muscle activity onset delay for the double-threshold method across all participants was 149 ± 152 milliseconds for the multifidus and 252 ± 204 milliseconds for the erector spinae. The average onset delay for the cross-correlation method was 26 ± 101 for the multifidus and 67 ± 116 for the erector spinae. There were no statistical interactions, and a main effect of method demonstrated that the delays were higher when using the double-threshold method compared with cross-correlation. The threshold parameters that best characterized activity onset delays were an 8-SD amplitude and a 10-millisecond duration threshold. The double-threshold method correlated well with visual supervision of muscle activity. The cross-correlation method provides several advantages in signal processing; however, supervision was required for some results, negating this advantage. These results help standardize methods when recording neuromuscular responses of spinal manipulation and improve comparisons within and across investigations. Copyright © 2016 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  14. Line length dependence of threshold current density and driving force in eutectic SnPb and SnAgCu solder electromigration

    NASA Astrophysics Data System (ADS)

    Yoon, Min-Seung; Ko, Min-Ku; Kim, Bit-Na; Kim, Byung-Joon; Park, Yong-Bae; Joo, Young-Chang

    2008-04-01

    The relationship between the threshold current density and the critical line length in eutectic SnPb and SnAgCu electromigrations were examined using solder lines with the various lengths ranging from 100to1000μm. When the electron wind-force was balanced by the back-stress gradient force, the net flux of electromigration is zero, at which the current density and line length are defined as the threshold current density and the critical length, respectively. It was found that in SnAgCu electromigration, the 1/L dependence on the threshold current density showed good agreement, whereas the threshold current densities of the eutectic SnPb deviated from the 1/L dependence. The balance between the electron wind-force and the back-stress gradient force was the main factor determining the threshold product of SnAgCu electromigration. On the other hand, in the case of eutectic SnPb, the chemical driving force is contributed as a back-flux force in addition to the back-stress gradient force. The existence of the chemical driving force was caused by the nonequilibrium Pb concentration inside the Pb-rich phases between the cathode and anode during the electromigration procedure.

  15. The impact of manual threshold selection in medical additive manufacturing.

    PubMed

    van Eijnatten, Maureen; Koivisto, Juha; Karhu, Kalle; Forouzanfar, Tymour; Wolff, Jan

    2017-04-01

    Medical additive manufacturing requires standard tessellation language (STL) models. Such models are commonly derived from computed tomography (CT) images using thresholding. Threshold selection can be performed manually or automatically. The aim of this study was to assess the impact of manual and default threshold selection on the reliability and accuracy of skull STL models using different CT technologies. One female and one male human cadaver head were imaged using multi-detector row CT, dual-energy CT, and two cone-beam CT scanners. Four medical engineers manually thresholded the bony structures on all CT images. The lowest and highest selected mean threshold values and the default threshold value were used to generate skull STL models. Geometric variations between all manually thresholded STL models were calculated. Furthermore, in order to calculate the accuracy of the manually and default thresholded STL models, all STL models were superimposed on an optical scan of the dry female and male skulls ("gold standard"). The intra- and inter-observer variability of the manual threshold selection was good (intra-class correlation coefficients >0.9). All engineers selected grey values closer to soft tissue to compensate for bone voids. Geometric variations between the manually thresholded STL models were 0.13 mm (multi-detector row CT), 0.59 mm (dual-energy CT), and 0.55 mm (cone-beam CT). All STL models demonstrated inaccuracies ranging from -0.8 to +1.1 mm (multi-detector row CT), -0.7 to +2.0 mm (dual-energy CT), and -2.3 to +4.8 mm (cone-beam CT). This study demonstrates that manual threshold selection results in better STL models than default thresholding. The use of dual-energy CT and cone-beam CT technology in its present form does not deliver reliable or accurate STL models for medical additive manufacturing. New approaches are required that are based on pattern recognition and machine learning algorithms.

  16. Formant discrimination in noise for isolated vowels

    NASA Astrophysics Data System (ADS)

    Liu, Chang; Kewley-Port, Diane

    2004-11-01

    Formant discrimination for isolated vowels presented in noise was investigated for normal-hearing listeners. Discrimination thresholds for F1 and F2, for the seven American English vowels /eye, smcapi, eh, æ, invv, aye, you/, were measured under two types of noise, long-term speech-shaped noise (LTSS) and multitalker babble, and also under quiet listening conditions. Signal-to-noise ratios (SNR) varied from -4 to +4 dB in steps of 2 dB. All three factors, formant frequency, signal-to-noise ratio, and noise type, had significant effects on vowel formant discrimination. Significant interactions among the three factors showed that threshold-frequency functions depended on SNR and noise type. The thresholds at the lowest levels of SNR were highly elevated by a factor of about 3 compared to those in quiet. The masking functions (threshold vs SNR) were well described by a negative exponential over F1 and F2 for both LTSS and babble noise. Speech-shaped noise was a slightly more effective masker than multitalker babble, presumably reflecting small benefits (1.5 dB) due to the temporal variation of the babble. .

  17. About the relevance of waviness, agglomeration, and strain on the electrical behavior of polymer composites filled with carbon nanotubes evaluated by a Monte-Carlo simulation

    NASA Astrophysics Data System (ADS)

    Román, Sebastián; Lund, Fernando; Bustos, Javier; Palza, Humberto

    2018-01-01

    In several technological applications, carbon nanotubes (CNT) are added to a polymer matrix in order to develop electrically conductive composite materials upon percolation of the CNT network. This percolation state depends on several parameters such as particle characteristics, degree of dispersion, and filler orientation. For instance, CNT aggregation is currently avoided because it is thought that it will have a negative effect on the electrical behavior despite some experimental evidence showing the contrary. In this study, the effect of CNT waviness, degree of agglomeration, and external strain, on the electrical percolation of polymer composites is studied by a three dimensional Monte-Carlo simulation. The simulation shows that the percolation threshold of CNT depends on the particle waviness, with rigid particles displaying the lowest values. Regarding the effect of CNT dispersion, our numerical results confirm that low levels of agglomeration reduce the percolation threshold of the composite. However, the threshold is shifted to larger values at high agglomeration states because of the appearance of isolated areas of high CNT concentrations. These results imply, therefore, an optimum of agglomeration that further depends on the waviness and concentration of CNT. Significantly, CNT agglomeration can further explain the broad percolation transition found in these systems. When an external strain is applied to the composites, the percolation concentration shifts to higher values because CNT alignment increases the inter-particle distances. The strain sensitivity of the composites is affected by the percolation state of CNT showing a maximum value at certain filler concentration. These results open up the discussion about the relevance in polymer composites of the dispersion state of CNT and filler flexibility towards electrically conductive composites.

  18. Inertial Gait Phase Detection for control of a drop foot stimulator Inertial sensing for gait phase detection.

    PubMed

    Kotiadis, D; Hermens, H J; Veltink, P H

    2010-05-01

    An Inertial Gait Phase Detection system was developed to replace heel switches and footswitches currently being used for the triggering of drop foot stimulators. A series of four algorithms utilising accelerometers and gyroscopes individually and in combination were tested and initial results are shown. Sensors were positioned on the outside of the upper shank. Tests were performed on data gathered from a subject, sufferer of stroke, implanted with a drop foot stimulator and triggered with the current trigger, the heel switch. Data tested includes a variety of activities representing everyday life. Flat surface walking, rough terrain and carpet walking show 100% detection and the ability of the algorithms to ignore non-gait events such as weight shifts. Timing analysis is performed against the current triggering method, the heel switch. After evaluating the heel switch timing against a reference system, namely the Vicon 370 marker and force plates system. Initial results show a close correlation between the current trigger detection and the inertial sensor based triggering algorithms. Algorithms were tested for stairs up and stairs down. Best results are observed for algorithms using gyroscope data. Algorithms were designed using threshold techniques for lowest possible computational load and with least possible sensor components to minimize power requirements and to allow for potential future implantation of sensor system.

  19. Spontaneous recombination current in InGaAs/GaAs quantum well lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blood, P.; Fletcher, E.D.; Woodbridge, K.

    1990-10-08

    We have studied the intrinsic factors which determine the threshold current and its temperature dependence in 160-A-wide In{sub 0.2}Ga{sub 0.8}As single well quantum lasers with GaAs barriers, grown by molecular beam epitaxy on GaAs substrates. By measuring the relative temperature dependence of the spontaneous emission intensity at threshold we show that radiative transitions between higher order ({ital n}=2,3) electron and heavy hole subbands make a significant contribution to the threshold current and its temperature sensitivity, even in devices where the laser transitions are between {ital n}=1 subbands. These higher transitions will also influence the dependence of threshold current and itsmore » temperature sensitivity on well width.« less

  20. Nerve Fiber Activation During Peripheral Nerve Field Stimulation: Importance of Electrode Orientation and Estimation of Area of Paresthesia.

    PubMed

    Frahm, Ken Steffen; Hennings, Kristian; Vera-Portocarrero, Louis; Wacnik, Paul W; Mørch, Carsten Dahl

    2016-04-01

    Low back pain is one of the indications for using peripheral nerve field stimulation (PNFS). However, the effect of PNFS varies between patients; several stimulation parameters have not been investigated in depth, such as orientation of the nerve fiber in relation to the electrode. While placing the electrode parallel to the nerve fiber may give lower activation thresholds, anodal blocking may occur when the propagating action potential passes an anode. A finite element model was used to simulate the extracellular potential during PNFS. This was combined with an active cable model of Aβ and Aδ nerve fibers. It was investigated how the angle between the nerve fiber and electrode affected the nerve activation and whether anodal blocking could occur. Finally, the area of paresthesia was estimated and compared with any concomitant Aδ fiber activation. The lowest threshold was found when nerve and electrode were in parallel, and that anodal blocking did not appear to occur during PNFS. The activation of Aβ fibers was within therapeutic range (<10V) of PNFS; however, within this range, Aδ fiber activation also may occur. The combined area of activated Aβ fibers (paresthesia) was at least two times larger than Aδ fibers for similar stimulation intensities. No evidence of anodal blocking was observed in this PNFS model. The thresholds were lowest when the nerves and electrodes were parallel; thus, it may be relevant to investigate the overall position of the target nerve fibers prior to electrode placement. © 2015 International Neuromodulation Society.

  1. A comparison of the fragmentation thresholds and inertial cavitation doses of different ultrasound contrast agents

    NASA Astrophysics Data System (ADS)

    Chen, Wen-Shiang; Matula, Thomas J.; Brayman, Andrew A.; Crum, Lawrence A.

    2003-01-01

    Contrast bubble destruction is important in several new diagnostic and therapeutic applications. The pressure threshold of destruction is determined by the shell material, while the propensity for of the bubbles to undergo inertial cavitation (IC) depends both on the gas and shell properties of the ultrasound contrast agent (UCA). The ultrasonic fragmentation thresholds of three specific UCAs (Optison, Sonazoid, and biSpheres), each with different shell and gas properties, were determined under various acoustic conditions. The acoustic emissions generated by the agents, or their derivatives, characteristic of IC after fragmentation, was also compared, using cumulated broadband-noise emissions (IC ``dose''). Albumin-shelled Optison and surfactant-shelled Sonazoid had low fragmentation thresholds (mean=0.13 and 0.15 MPa at 1.1 MHz, 0.48 and 0.58 MPa at 3.5 MHz, respectively), while polymer-shelled biSpheres had a significant higher threshold (mean=0.19 and 0.23 MPa at 1.1 MHz, 0.73 and 0.96 MPa for thin- and thick-shell biSpheres at 3.5 MHz, respectively, p<0.01). At comparable initial concentrations, surfactant-shelled Sonazoid produced a much larger IC dose after shell destruction than did either biSpheres or Optison (p<0.01). Thick-shelled biSpheres had the highest fragmentation threshold and produced the lowest IC dose. More than two and five acoustic cycles, respectively, were necessary for the thin- and thick-shell biSpheres to reach a steady-state fragmentation threshold.

  2. Identifying the most appropriate age threshold for TNM stage grouping of well-differentiated thyroid cancer.

    PubMed

    Hendrickson-Rebizant, J; Sigvaldason, H; Nason, R W; Pathak, K A

    2015-08-01

    Age is integrated in most risk stratification systems for well-differentiated thyroid cancer (WDTC). The most appropriate age threshold for stage grouping of WDTC is debatable. The objective of this study was to evaluate the best age threshold for stage grouping by comparing multivariable models designed to evaluate the independent impact of various prognostic factors, including age based stage grouping, on the disease specific survival (DSS) of our population-based cohort. Data from population-based thyroid cancer cohort of 2125 consecutive WDTC, diagnosed during 1970-2010, with a median follow-up of 11.5 years, was used to calculate DSS using the Kaplan Meier method. Multivariable analysis with Cox proportional hazard model was used to assess independent impact of different prognostic factors on DSS. The Akaike information criterion (AIC), a measure of statistical model fit, was used to identify the most appropriate age threshold model. Delta AIC, Akaike weight, and evidence ratios were calculated to compare the relative strength of different models. The mean age of the patients was 47.3 years. DSS of the cohort was 95.6% and 92.8% at 10 and 20 years respectively. A threshold of 55 years, with the lowest AIC, was identified as the best model. Akaike weight indicated an 85% chance that this age threshold is the best among the compared models, and is 16.8 times more likely to be the best model as compared to a threshold of 45 years. The age threshold of 55 years was found to be the best for TNM stage grouping. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Acoustic reflex on newborns: the influence of the 226 and 1,000 Hz probes.

    PubMed

    Jacob-Corteletti, Lilian Cássia Bórnia; Duarte, Josilene Luciene; Zucki, Fernanda; Mariotto, Luciane Domingues Figueiredo; Lauris, José Roberto Pereira; Alvarenga, Kátia de Freitas

    2015-01-01

    To analyze the occurrence of acoustic reflex and its threshold on newborns using the 226 and 1,000 Hz probes. Thirty-six newborns with "PASS" results in newborn hearing screening and tympanogram with one or two peaks for both probe tones were included. Group I comprised 20 full-term newborns without risk indicator for hearing loss, and Group II comprised 16 newborns with at least one risk indicator. The study about ipsilateral acoustic reflex thresholds was conducted in 500, 1,000, 2,000, and 4,000 Hz. The groups presented the acoustic reflex thresholds between 50 and 100 dB for both probe tones. In the comparison between the probes, there were differences in all frequencies evaluated in Group I, with the lowest threshold mean for the 1,000 Hz probe. In Group II, differences were detected at 2,000 Hz. The mean acoustic reflex thresholds were similar in both groups for the 226 Hz probe. There was a difference for the 1,000 Hz probe in all tested frequencies. The percentage of response was higher in both groups for the 1,000 Hz probe. The kappa test showed extremely poor agreement in the comparison of results between both probes. The occurrence of acoustic reflex was higher in newborns and its thresholds were lower with the 1,000 Hz probe both for healthy newborns and for newborns at risk.

  4. Relationship of extinction to perceptual thresholds for single stimuli.

    PubMed

    Meador, K J; Ray, P G; Day, L J; Loring, D W

    2001-04-24

    To demonstrate the effects of target stimulus intensity on extinction to double simultaneous stimuli. Attentional deficits contribute to extinction in patients with brain lesions, but extinction (i.e., masking) can also be produced in healthy subjects. The relationship of extinction to perceptual thresholds for single stimuli remains uncertain. Brief electrical pulses were applied simultaneously to the left and right index fingers of 16 healthy volunteers (8 young and 8 elderly adults) and 4 patients with right brain stroke (RBS). The stimulus to be perceived (i.e., target stimulus) was given at the lowest perceptual threshold to perceive any single stimulus (i.e., Minimal) and at the threshold to perceive 100% of single stimuli. The mask stimulus (i.e., stimulus given to block the target) was applied to the contralateral hand at intensities just below discomfort. Extinction was less for target stimuli at 100% than Minimal threshold for healthy subjects. Extinction of left targets was greater in patients with RBS than elderly control subjects. Left targets were extinguished less than right in healthy subjects. In contrast, the majority of left targets were extinguished in patients with RBS even when right mask intensity was reduced below right 100% threshold for single stimuli. RBS patients had less extinction for right targets despite having greater left mask - threshold difference than control subjects. In patients with RBS, right "targets" at 100% threshold extinguished left "masks" (20%) almost as frequently as left masks extinguished right targets (32%). Subtle changes in target intensity affect extinction in healthy adults. Asymmetries in mask and target intensities (relative to single-stimulus perceptual thresholds) affect extinction in RBS patients less for left targets but more for right targets as compared with control subjects.

  5. The immediate effects of lidocaine iontophoresis using interferential current on pressure sense threshold and tactile sensation.

    PubMed

    Yoosefinejad, Amin Kordi; Motealleh, Alireza; Abbasnia, Keramatollah

    2016-01-01

    Iontophoresis is the noninvasive delivery of ions using direct current. The direct current has some disadvantages such as skin burning. Interferential current is a kind of alternating current without limitations of direct current; so the purpose of this study is to investigate and compare the effects of lidocaine, interferential current and lidocaine iontophoresis using interferential current. 30 healthy women aged 20-24 years participated in this randomized clinical trial study. Pressure, tactile and pain thresholds were evaluated before and after the application of treatment methods. Pressure, tactile and pain sensitivity increased significantly after the application of lidocaine alone (p < 0.005) and lidocaine iontophoresis using interferential current (p < 0.0001). Lidocaine iontophoresis using interferential current can increase perception threshold of pain, tactile stimulus and pressure sense more significantly than lidocaine and interferential current alone.

  6. The influence of different signal-to-background ratios on spatial resolution and F18-FDG-PET quantification using point spread function and time-of-flight reconstruction.

    PubMed

    Rogasch, Julian Mm; Hofheinz, Frank; Lougovski, Alexandr; Furth, Christian; Ruf, Juri; Großer, Oliver S; Mohnike, Konrad; Hass, Peter; Walke, Mathias; Amthauer, Holger; Steffen, Ingo G

    2014-12-01

    F18-fluorodeoxyglucose positron-emission tomography (FDG-PET) reconstruction algorithms can have substantial influence on quantitative image data used, e.g., for therapy planning or monitoring in oncology. We analyzed radial activity concentration profiles of differently reconstructed FDG-PET images to determine the influence of varying signal-to-background ratios (SBRs) on the respective spatial resolution, activity concentration distribution, and quantification (standardized uptake value [SUV], metabolic tumor volume [MTV]). Measurements were performed on a Siemens Biograph mCT 64 using a cylindrical phantom containing four spheres (diameter, 30 to 70 mm) filled with F18-FDG applying three SBRs (SBR1, 16:1; SBR2, 6:1; SBR3, 2:1). Images were reconstructed employing six algorithms (filtered backprojection [FBP], FBP + time-of-flight analysis [FBP + TOF], 3D-ordered subset expectation maximization [3D-OSEM], 3D-OSEM + TOF, point spread function [PSF], PSF + TOF). Spatial resolution was determined by fitting the convolution of the object geometry with a Gaussian point spread function to radial activity concentration profiles. MTV delineation was performed using fixed thresholds and semiautomatic background-adapted thresholding (ROVER, ABX, Radeberg, Germany). The pairwise Wilcoxon test revealed significantly higher spatial resolutions for PSF + TOF (up to 4.0 mm) compared to PSF, FBP, FBP + TOF, 3D-OSEM, and 3D-OSEM + TOF at all SBRs (each P < 0.05) with the highest differences for SBR1 decreasing to the lowest for SBR3. Edge elevations in radial activity profiles (Gibbs artifacts) were highest for PSF and PSF + TOF declining with decreasing SBR (PSF + TOF largest sphere; SBR1, 6.3%; SBR3, 2.7%). These artifacts induce substantial SUVmax overestimation compared to the reference SUV for PSF algorithms at SBR1 and SBR2 leading to substantial MTV underestimation in threshold-based segmentation. In contrast, both PSF algorithms provided the lowest deviation of SUVmean from reference SUV at SBR1 and SBR2. At high contrast, the PSF algorithms provided the highest spatial resolution and lowest SUVmean deviation from the reference SUV. In contrast, both algorithms showed the highest deviations in SUVmax and threshold-based MTV definition. At low contrast, all investigated reconstruction algorithms performed approximately equally. The use of PSF algorithms for quantitative PET data, e.g., for target volume definition or in serial PET studies, should be performed with caution - especially if comparing SUV of lesions with high and low contrasts.

  7. Synergy of adaptive thresholds and multiple transmitters in free-space optical communication.

    PubMed

    Louthain, James A; Schmidt, Jason D

    2010-04-26

    Laser propagation through extended turbulence causes severe beam spread and scintillation. Airborne laser communication systems require special considerations in size, complexity, power, and weight. Rather than using bulky, costly, adaptive optics systems, we reduce the variability of the received signal by integrating a two-transmitter system with an adaptive threshold receiver to average out the deleterious effects of turbulence. In contrast to adaptive optics approaches, systems employing multiple transmitters and adaptive thresholds exhibit performance improvements that are unaffected by turbulence strength. Simulations of this system with on-off-keying (OOK) showed that reducing the scintillation variations with multiple transmitters improves the performance of low-frequency adaptive threshold estimators by 1-3 dB. The combination of multiple transmitters and adaptive thresholding provided at least a 10 dB gain over implementing only transmitter pointing and receiver tilt correction for all three high-Rytov number scenarios. The scenario with a spherical-wave Rytov number R=0.20 enjoyed a 13 dB reduction in the required SNR for BER's between 10(-5) to 10(-3), consistent with the code gain metric. All five scenarios between 0.06 and 0.20 Rytov number improved to within 3 dB of the SNR of the lowest Rytov number scenario.

  8. A field test for determining the speed obtained through anaerobic glycolysis in runners.

    PubMed

    Borsetto, C; Ballarin, E; Casoni, I; Cellini, M; Vitiello, P; Conconi, F

    1989-10-01

    A field test for the evaluation of the speed generated by the anaerobic lactacid mechanism has been developed in runners. The test consists of 1200 m of continuous running: in the first 1000 m the speed corresponding to the anaerobic threshold is progressively reached; in the last 200 m an all-out sprint is performed. The speed at the anaerobic threshold is subtracted from the speed reached in the final 200-m all-out sprint. In 39 runners examined (marathon runners, n = 13; 5000-10000-m runners, n = 10; 400-800-m runners, n = 7; sprinters, n = 9), the additional speed generated above the anaerobic threshold was correlated with the venous blood lactate concentration reached 5 min after the all-out effort (r = 0.93). The anaerobic speeds measured by the test were in keeping with the characteristics of the runners under study, i.e., anaerobic speeds were highest for the sprinters, intermediate for the middle-distance runners, and lowest for the marathon runners. Since the speed generated above the anaerobic threshold by the aerobic fuel breakdown can be subtracted, the contribution of creatine phosphate is minimal, and the speed exceeding the anaerobic threshold is highly correlated with lactate accumulation, the present test should measure the speed generated by anaerobic glycolysis.

  9. Very Low Threshold ASE and Lasing Using Auger-Suppressed Nanocrystal Quantum Dots

    NASA Astrophysics Data System (ADS)

    Park, Young-Shin; Bae, Wan Ki; Fidler, Andrew; Baker, Tomas; Lim, Jaehoon; Pietryga, Jeffrey; Klimov, Victor

    2015-03-01

    We report amplified spontaneous emission (ASE) and lasing with very low thresholds obtained using thin films made of engineered thick-shell CdSe/CdS QDs that have a CdSeS alloyed layer between the CdSe core and the CdS shell. These ``alloyed'' QDs exhibit considerable reduction of Auger decay rates, which results in high biexciton emission quantum yields (QBX of ~ 12%) and extended biexciton lifetimes (τBX of ~ 4ns). By using a fs laser (400 nm at 1 kHz repetition rate) as a pump source, we measured the threshold intensity of biexciton ASE as low as 5 μJ/cm2, which is about 5 times lower than the lowest ASE thresholds reported for thick-shell QDs without interfacial alloying. Interestingly, we also observed biexciton random lasing from the same QD film. Lasing spectrum comprises several sharp peaks (linewidth ~0.2 nm), and the heights and the spectral positions of these peaks show strong dependence on the exact position of the excitation spot on the QD film. Our study suggests that further suppression of nonradiative Auger decay rates via even finer grading of the core/shell interface could lead to a further reduction in the lasing threshold and potentially realization of lasing under continuous-wave excitation.

  10. Synthesis of polymer nanostructures with conductance switching properties

    DOEpatents

    Su, Kai; Nuraje, Nurxat; Zhang, Lingzhi; Matsui, Hiroshi; Yang, Nan Loh

    2015-03-03

    The present invention is directed to crystalline organic polymer nanoparticles comprising a conductive organic polymer; wherein the crystalline organic polymer nanoparticles have a size of from 10 nm to 200 nm and exhibits two current-voltage states: (1) a high resistance current-voltage state, and (2) a low resistance current-voltage state, wherein when a first positive threshold voltage (V.sub.th1) or higher positive voltage, or a second negative threshold voltage (V.sub.th2) or higher negative voltage is applied to the nanoparticle, the nanoparticle exhibits the low-resistance current-voltage state, and when a voltage less positive than the first positive threshold voltage or a voltage less negative than the second negative threshold voltage is applied to the nanoparticle, the nanoparticle exhibits the high-resistance current-voltage state. The present invention is also directed methods of manufacturing the nanoparticles using novel interfacial oxidative polymerization techniques.

  11. Investigating the effect of freeway congestion thresholds on decision-making inputs.

    DOT National Transportation Integrated Search

    2010-05-01

    Congestion threshold is embedded in the congestion definition. Two basic approaches exist in : current practice for setting the congestion threshold. One common approach uses the free-flow or : unimpeded conditions as the congestion threshold. ...

  12. Axonal Dysfunction Precedes Motor Neuronal Death in Amyotrophic Lateral Sclerosis

    PubMed Central

    Iwai, Yuta; Shibuya, Kazumoto; Misawa, Sonoko; Sekiguchi, Yukari; Watanabe, Keisuke; Amino, Hiroshi; Kuwabara, Satoshi

    2016-01-01

    Wide-spread fasciculations are a characteristic feature in amyotrophic lateral sclerosis (ALS), suggesting motor axonal hyperexcitability. Previous excitability studies have shown increased nodal persistent sodium conductances and decreased potassium currents in motor axons of ALS patients, both of the changes inducing hyperexcitability. Altered axonal excitability potentially contributes to motor neuron death in ALS, but the relationship of the extent of motor neuronal death and abnormal excitability has not been fully elucidated. We performed multiple nerve excitability measurements in the median nerve at the wrist of 140 ALS patients and analyzed the relationship of compound muscle action potential (CMAP) amplitude (index of motor neuronal loss) and excitability indices, such as strength-duration time constant, threshold electrotonus, recovery cycle and current-threshold relationships. Compared to age-matched normal controls (n = 44), ALS patients (n = 140) had longer strength-duration time constant (SDTC: a measure of nodal persistent sodium current; p < 0.05), greater threshold changes in depolarizing threshold electrotonus (p < 0.05) and depolarizing current threshold relationship (i.e. less accommodation; (p < 0.05), greater superexcitability (a measure of fast potassium current; p < 0.05) and reduced late subexcitability (a measure of slow potassium current; p < 0.05), suggesting increased persistent sodium currents and decreased potassium currents. The reduced potassium currents were found even in the patient subgroups with normal CMAP (> 5mV). Regression analyses showed that SDTC (R = -0.22) and depolarizing threshold electrotonus (R = -0.22) increased with CMAP decline. These findings suggest that motor nerve hyperexcitability occurs in the early stage of the disease, and precedes motor neuronal loss in ALS. Modulation of altered ion channel function could be a treatment option for ALS. PMID:27383069

  13. Dependence of threshold current on the number of wells in AlGaAs-GaAs quantum well lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blood, P.; Fletcher, E.D.; Woodbridge, K.

    1985-08-01

    GaAs-AlGaAs multiple quantum well injection lasers have been grown by molecular beam epitaxy with different numbers (N) of uncoupled GaAs wells 25 A wide symmetrically disposed about the center of a 4000-A-wide waveguide. The devices emit at about 770 nm and for N = 4 the broad area threshold current density is 1.1 kA cm/sup -2/. The threshold current increases with increasing N (2

  14. Effect of Aluminum Particle Size on the Impact Initiation of Pressed Ptfe/al Composite Rods

    NASA Astrophysics Data System (ADS)

    Mock, Willis; Drotar, Jason T.

    2007-12-01

    A gas gun has been used to investigate the impact initiation of rods of a mixture of 72 wt% PTFE (polytetrafluoroethylene) and 28 wt% aluminum powders. The rods were sabot-launched in vacuum into steel anvils at impact velocities ranging from 468 to 969 m/s. A framing camera was used to observe the time sequence of events following impact. At the lowest impact stress of 25 kbar no light was observed. Above the initiation threshold, the initiation time dropped from 74 μs just above threshold to 14 μs at 64 kbar. These results are compared with earlier rod impact experiments for a similar material in which the only major difference is a smaller aluminum particle size.

  15. Nanosecond-pulsed Q-switched Nd:YAG laser at 1064 nm with a gold nanotriangle saturable absorber

    NASA Astrophysics Data System (ADS)

    Chen, Xiaohan; Li, Ping; Dun, Yangyang; Song, Teng; Ma, Baomin

    2018-06-01

    Gold nanotriangles (GNTs) were successfully employed as a saturable absorber (SA) to achieve passively Q-switched lasers for the first time. The performance of the Q-switched Nd:YAG laser at 1064 nm has been systematically investigated. The corresponding shortest pulsewidth, the threshold pump power and the maximum Q-switched average output power were 275.5 ns, 1.37 W, and 171 mW, respectively. To our knowledge, this is the shortest pulsewidth and the lowest threshold in a passively Q-switched laser at approximately 1.1 µm based on a gold nanoparticle SA (GNPs-SA). Our experimental results proved that the GNTs-SA can be used as a promising saturable absorber for nanosecond-pulsed lasers.

  16. Spike threshold dynamics in spinal motoneurons during scratching and swimming.

    PubMed

    Grigonis, Ramunas; Alaburda, Aidas

    2017-09-01

    Action potential threshold can vary depending on firing history and synaptic inputs. We used an ex vivo carapace-spinal cord preparation from adult turtles to study spike threshold dynamics in motoneurons during two distinct types of functional motor behaviour - fictive scratching and fictive swimming. The threshold potential depolarizes by about 10 mV within each burst of spikes generated during scratch and swim network activity and recovers between bursts to a slightly depolarized level. Slow synaptic integration resulting in a wave of membrane potential depolarization is the factor influencing the threshold potential within firing bursts during motor behaviours. Depolarization of the threshold potential decreases the excitability of motoneurons and may provide a mechanism for stabilization of the response of a motoneuron to intense synaptic inputs to maintain the motor commands within an optimal range for muscle activation. During functional spinal neural network activity motoneurons receive intense synaptic input, and this could modulate the threshold for action potential generation, providing the ability to dynamically adjust the excitability and recruitment order for functional needs. In the present study we investigated the dynamics of action potential threshold during motor network activity. Intracellular recordings from spinal motoneurons in an ex vivo carapace-spinal cord preparation from adult turtles were performed during two distinct types of motor behaviour - fictive scratching and fictive swimming. We found that the threshold of the first spike in episodes of scratching and swimming was the lowest. The threshold potential depolarizes by about 10 mV within each burst of spikes generated during scratch and swim network activity and recovers between bursts to a slightly depolarized level. Depolarization of the threshold potential results in decreased excitability of motoneurons. Synaptic inputs do not modulate the threshold of the first action potential during episodes of scratching or of swimming. There is no correlation between changes in spike threshold and interspike intervals within bursts. Slow synaptic integration that results in a wave of membrane potential depolarization rather than fast synaptic events preceding each spike is the factor influencing the threshold potential within firing bursts during motor behaviours. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.

  17. Lead exposure and the 2010 achievement test scores of children in New York counties

    PubMed Central

    2012-01-01

    Background Lead is toxic to cognitive and behavioral functioning in children even at levels well below those producing physical symptoms. Continuing efforts in the U.S. since about the 1970s to reduce lead exposure in children have dramatically reduced the incidence of elevated blood lead levels (with elevated levels defined by the current U.S. Centers for Disease Control threshold of 10 μg/dl). The current study examines how much lead toxicity continues to impair the academic achievement of children of New York State, using 2010 test data. Methods This study relies on three sets of data published for the 57 New York counties outside New York City: school achievement data from the New York State Department of Education, data on incidence of elevated blood lead levels from the New York State Department of Health, and data on income from the U.S. Census Bureau. We studied third grade and eighth grade test scores in English Language Arts and mathematics. Using the county as the unit of analysis, we computed bivariate correlations and regression coefficients, with percent of children achieving at the lowest reported level as the dependent variable and the percent of preschoolers in the county with elevated blood lead levels as the independent variable. Then we repeated those analyses using partial correlations to control for possible confounding effects of family income, and using multiple regressions with income included. Results The bivariate correlations between incidence of elevated lead and number of children in the lowest achievement group ranged between 0.38 and 0.47. The partial correlations ranged from 0.29 to 0.40. The regression coefficients, both bivariate and partial (both estimating the increase in percent of children in the lowest achievement group for every percent increase in the children with elevated blood lead levels), ranged from 0.52 to 1.31. All regression coefficients, when rounded to the nearest integer, were approximately 1. Thus, when the percent of children showing elevated lead increases by one percent, the percent of children in the lowest achievement group, according to the regression equations generated, also increases by about one percent. All associations were significant at the 0.05 level. Conclusion Despite public health advances, and despite the imprecision of measures, an association between the incidence of elevated blood lead and achievement in New York counties is still apparent, not attributable to confounding by income. Efforts to reduce lead exposure should persist with vigor. PMID:22269775

  18. Effect of laryngotracheal topical anesthesia on recurrent laryngeal nerve monitoring during thyroid Surgery.

    PubMed

    Pachuski, Justin; Vaida, Sonia; Donahue, Kathleen; Roberts, John; Kunselman, Allen; Oberman, Benjamin; Patel, Hetal; Goldenberg, David

    2016-03-01

    Intraoperative neuromonitoring of the recurrent laryngeal nerve (RLN) is often used as an adjunct for RLN identification and preservation during thyroidectomies. Laryngotracheal anesthesia (LTA) with topical lidocaine reduces coughing upon emergence from anesthesia and in the immediate postoperative period; however, its use is prohibited with concerns that it could decrease the sensitivity of the intraoperative neuromonitoring. We hypothesize that there is no difference in measurements of nerve conduction made before and after LTA administration. An observational study in which all patients were subjected to LTA administration was conducted. Recurrent laryngeal nerve threshold currents were measured before and after the intervention. Tertiary medical center operating room. Eighteen patients (total of 25 nerves at risk) with American Society of Anesthesiologists classes 1 to 3 undergoing thyroid surgery. After the thyroid was removed and threshold currents at the RLN were obtained, LTA with endotracheal lidocaine was applied on the left and right side of the in situ endotracheal tube (2 cc of 4% lidocaine per side). Threshold currents were reassessed at 5 and 10 minutes after LTA administration. Threshold currents (minimum stimulus current applied to the RLN required to generate a discernible electromyographic response at the vocal cords) were recorded along the RLN for a baseline at 5 and 10 mm from the insertion point of the RLN into the larynx. Threshold currents were reassessed at the same 2 positions on the RLN at 5 and 10 minutes after LTA administration. Differences in mean values, between threshold currents recorded at the 3 different times, at 2 positions on the RLN, were used to compare effects of LTA on nerve conduction. There were no statistically significant differences when comparing threshold currents before and after LTA administration. Laryngotracheal anesthesia had no significant effect on RLN nerve conduction in the period assessed. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Photon Energy Threshold in Direct Photocatalysis with Metal Nanoparticles: Key Evidence from the Action Spectrum of the Reaction.

    PubMed

    Sarina, Sarina; Jaatinen, Esa; Xiao, Qi; Huang, Yi Ming; Christopher, Philip; Zhao, Jin Cai; Zhu, Huai Yong

    2017-06-01

    By investigating the action spectra (the relationship between the irradiation wavelength and apparent quantum efficiency of reactions under constant irradiance) of a number of reactions catalyzed by nanoparticles including plasmonic metals, nonplasmonic metals, and their alloys at near-ambient temperatures, we found that a photon energy threshold exists in each photocatalytic reaction; only photons with sufficient energy (e.g., higher than the energy level of the lowest unoccupied molecular orbitals) can initiate the reactions. This energy alignment (and the photon energy threshold) is determined by various factors, including the wavelength and intensity of irradiation, molecule structure, reaction temperature, and so forth. Hence, distinct action spectra were observed in the same type of reaction catalyzed by the same catalyst due to a different substituent group, a slightly changed reaction temperature. These results indicate that photon-electron excitations, instead of the photothermal effect, play a dominant role in direct photocatalysis of metal nanoparticles for many reactions.

  20. Effects of electrolysis by low-amperage electric current on the chlorophyll fluorescence characteristics of Microcystis aeruginosa.

    PubMed

    Lin, Li; Feng, Cong; Li, Qingyun; Wu, Min; Zhao, Liangyuan

    2015-10-01

    Effects of electrolysis by low-amperage electric current on the chlorophyll fluorescence characteristics of Microcystis aeruginosa were investigated in order to reveal the mechanisms of electrolytic inhibition of algae. Threshold of current density was found under a certain initial no. of algae cell. When current density was equal to or higher than the threshold (fixed electrolysis time), growth of algae was inhibited completely and the algae lost the ability to survive. Effect of algal solution volume on algal inhibition was insignificant. Thresholds of current density were 8, 10, 14, 20, and 22 mA cm(-2) at 2.5 × 10(7), 5 × 10(7), 1 × 10(8), 2.5 × 10(8), and 5 × 10(8) cells mL(-1) initial no. of algae cell, respectively. Correlativity between threshold of current and initial no. of algae cells was established for scale-up and determining operating conditions. Changes of chlorophyll fluorescence parameters demonstrated that photosystem (PS) II of algae was damaged by electrolysis but still maintained relatively high activity when algal solution was treated by current densities lower than the threshold. The activity of algae recovered completely after 6 days of cultivation. On the contrary, when current density was higher than the threshold, connection of phycobilisome (PBS) and PS II core complexes was destroyed, PS II system of algae was damaged irreversibly, and algae could not survive thoroughly. The inactivation of M. aeruginosa by electrolysis can be attributed to irreversible separation of PBS from PS II core complexes and the damage of PS II of M. aeruginosa.

  1. Long-term thresholds of nonsteroidal permanent pacing leads: a 5-year study.

    PubMed

    Gumbrielle, T P; Bourke, J P; Sinkovic, M; Tynan, M; Kittpawong, P; Gold, R G

    1996-05-01

    The present commercial market supports many nonsteroidal endocardial pacing leads of differing construction. In order to compare the performance of these configurations, we studied the long-term pacing properties of three representative lead types by randomized clinical trial in 99 patients undergoing a first elective VVI implant. Thirty-one patients received sintered platinum leads, 36 activated pyrolytic carbon leads, and 32 vitreous carbon leads. All received generators capable of noninvasive threshold testing. Acute sensing parameters were R wave amplitude and ST segment elevation measured from the endocardial electrogram. Noninvasive voltage thresholds were measured at implantation, 2 days, 1, 3, and 6 months, and yearly thereafter for 5 years. There were no significant differences between leads in pacing or sensing capabilities at implantation. All three demonstrated similar increases in thresholds, peaking at 1 month, then falling to a plateau by 6 months and did not vary significantly thereafter. There were no significant differences in thresholds between leads during 5 years of follow-up. The lowest mean threshold at 5 years was 0.93 V at 0.5 ms. This study suggests that: (1) although these lead types all perform well, none offers any particular clinical advantage over another; (2) the degree of early threshold peaking precludes immediate postimplant output reduction, but later thresholds are sufficiently low to enable reductions in pacing output; (3) safe low energy pacing requires greater attention to the lead-generator combinations; (4) data obtained at subsequent annual follow-up provided no additional useful clinical information to that obtained at 1 year; and (5) in the absence of other differences, cost can be the deciding factor in lead selection.

  2. The simple ears of noctuoid moths are tuned to the calls of their sympatric bat community.

    PubMed

    ter Hofstede, Hannah M; Goerlitz, Holger R; Ratcliffe, John M; Holderied, Marc W; Surlykke, Annemarie

    2013-11-01

    Insects with bat-detecting ears are ideal animals for investigating sensory system adaptations to predator cues. Noctuid moths have two auditory receptors (A1 and A2) sensitive to the ultrasonic echolocation calls of insectivorous bats. Larger moths are detected at greater distances by bats than smaller moths. Larger moths also have lower A1 best thresholds, allowing them to detect bats at greater distances and possibly compensating for their increased conspicuousness. Interestingly, the sound frequency at the lowest threshold is lower in larger than in smaller moths, suggesting that the relationship between threshold and size might vary across frequencies used by different bat species. Here, we demonstrate that the relationships between threshold and size in moths were only significant at some frequencies, and these frequencies differed between three locations (UK, Canada and Denmark). The relationships were more likely to be significant at call frequencies used by proportionately more bat species in the moths' specific bat community, suggesting an association between the tuning of moth ears and the cues provided by sympatric predators. Additionally, we found that the best threshold and best frequency of the less sensitive A2 receptor are also related to size, and that these relationships hold when controlling for evolutionary relationships. The slopes of best threshold versus size differ, however, such that the difference in threshold between A1 and A2 is greater for larger than for smaller moths. The shorter time from A1 to A2 excitation in smaller than in larger moths could potentially compensate for shorter absolute detection distances in smaller moths.

  3. Carbon deposition thresholds on nickel-based solid oxide fuel cell anodes II. Steam:carbon ratio and current density

    NASA Astrophysics Data System (ADS)

    Kuhn, J.; Kesler, O.

    2015-03-01

    For the second part of a two part publication, coking thresholds with respect to molar steam:carbon ratio (SC) and current density in nickel-based solid oxide fuel cells were determined. Anode-supported button cell samples were exposed to 2-component and 5-component gas mixtures with 1 ≤ SC ≤ 2 and zero fuel utilization for 10 h, followed by measurement of the resulting carbon mass. The effect of current density was explored by measuring carbon mass under conditions known to be prone to coking while increasing the current density until the cell was carbon-free. The SC coking thresholds were measured to be ∼1.04 and ∼1.18 at 600 and 700 °C, respectively. Current density experiments validated the thresholds measured with respect to fuel utilization and steam:carbon ratio. Coking thresholds at 600 °C could be predicted with thermodynamic equilibrium calculations when the Gibbs free energy of carbon was appropriately modified. Here, the Gibbs free energy of carbon on nickel-based anode support cermets was measured to be -6.91 ± 0.08 kJ mol-1. The results of this two part publication show that thermodynamic equilibrium calculations with appropriate modification to the Gibbs free energy of solid-phase carbon can be used to predict coking thresholds on nickel-based anodes at 600-700 °C.

  4. Reconfigurable Solid-state Dye-doped Polymer Ring Resonator Lasers

    NASA Astrophysics Data System (ADS)

    Chandrahalim, Hengky; Fan, Xudong

    2015-12-01

    This paper presents wavelength configurable on-chip solid-state ring lasers fabricated by a single-mask standard lithography. The single- and coupled-ring resonator hosts were fabricated on a fused-silica wafer and filled with 3,3‧-Diethyloxacarbocyanine iodide (CY3), Rhodamine 6G (R6G), and 3,3‧-Diethylthiadicarbocyanine iodide (CY5)-doped polymer as the reconfigurable gain media. The recorded lasing threshold was ~220 nJ/mm2 per pulse for the single-ring resonator laser with R6G, marking the lowest threshold shown by solid-state dye-doped polymer lasers fabricated with a standard lithography process on a chip. A single-mode lasing from a coupled-ring resonator system with the lasing threshold of ~360 nJ/mm2 per pulse was also demonstrated through the Vernier effect. The renewability of the dye-doped polymer was examined by removing and redepositing the dye-doped polymer on the same resonator hosts for multiple cycles. We recorded consistent emissions from the devices for all trials, suggesting the feasibility of employing this technology for numerous photonic and biochemical sensing applications that entail for sustainable, reconfigurable, and low lasing threshold coherent light sources on a chip.

  5. Collision and phonation threshold pressures before and after loud, prolonged vocalization in trained and untrained voices.

    PubMed

    Enflo, Laura; Sundberg, Johan; McAllister, Anita

    2013-09-01

    The phonation threshold pressure (PTP) is defined as the lowest subglottal pressure needed for obtaining and sustaining vocal fold oscillation. It has been found to increase during vocal fatigue. In the present study, PTP is measured together with the threshold pressure needed for vocal fold collision; henceforth, the collision threshold pressure (CTP). PTP and CTP are compared before and after loud, prolonged vocalization in singer and nonsinger voices. Ten subjects repeated the vowel sequence /a, e, i, o, u/ at a Sound Pressure Level of at least 80 dB at 0.3 m for 20 minutes. Audio and electroglottography signals were recorded before and after this exercise. At the same time, oral pressure was registered while the subjects produced a diminuendo repeating the syllable /pa:/, thus acquiring an approximate of the subglottal pressure. CTP and PTP increased significantly after the vocal loading in the nonsinger subjects. On the other hand, singers reported no substantial effect of the exercise, and most singers had a mean after-to-before ratio close to 1 for both CTP and PTP. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  6. Reconfigurable Solid-state Dye-doped Polymer Ring Resonator Lasers

    PubMed Central

    Chandrahalim, Hengky; Fan, Xudong

    2015-01-01

    This paper presents wavelength configurable on-chip solid-state ring lasers fabricated by a single-mask standard lithography. The single- and coupled-ring resonator hosts were fabricated on a fused-silica wafer and filled with 3,3′-Diethyloxacarbocyanine iodide (CY3), Rhodamine 6G (R6G), and 3,3′-Diethylthiadicarbocyanine iodide (CY5)-doped polymer as the reconfigurable gain media. The recorded lasing threshold was ~220 nJ/mm2 per pulse for the single-ring resonator laser with R6G, marking the lowest threshold shown by solid-state dye-doped polymer lasers fabricated with a standard lithography process on a chip. A single-mode lasing from a coupled-ring resonator system with the lasing threshold of ~360 nJ/mm2 per pulse was also demonstrated through the Vernier effect. The renewability of the dye-doped polymer was examined by removing and redepositing the dye-doped polymer on the same resonator hosts for multiple cycles. We recorded consistent emissions from the devices for all trials, suggesting the feasibility of employing this technology for numerous photonic and biochemical sensing applications that entail for sustainable, reconfigurable, and low lasing threshold coherent light sources on a chip. PMID:26674508

  7. MRI-leukoaraiosis thresholds and the phenotypic expression of dementia

    PubMed Central

    Mitchell, Sandra M.; Brumback, Babette; Tanner, Jared J.; Schmalfuss, Ilona; Lamar, Melissa; Giovannetti, Tania; Heilman, Kenneth M.; Libon, David J.

    2012-01-01

    Objective: To examine the concept of leukoaraiosis thresholds on working memory, visuoconstruction, memory, and language in dementia. Methods: A consecutive series of 83 individuals with insidious onset/progressive dementia clinically diagnosed with Alzheimer disease (AD) or small vessel vascular dementia (VaD) completed neuropsychological measures assessing working memory, visuoconstruction, episodic memory, and language. A clinical MRI scan was used to quantify leukoaraiosis, total white matter, hippocampus, lacune, and intracranial volume. We performed analyses to detect the lowest level of leukoaraiosis associated with impairment on the neuropsychological measures. Results: Leukoaraiosis ranged from 0.63% to 23.74% of participants' white matter. Leukoaraiosis explained a significant amount of variance in working memory performance when it involved 3% or more of the white matter with curve estimations showing the relationship to be nonlinear in nature. Greater leukoaraiosis (13%) was implicated for impairment in visuoconstruction. Relationships between leukoaraiosis, episodic memory, and language measures were linear or flat. Conclusions: Leukoaraiosis involves specific threshold points for working memory and visuoconstructional tests in AD/VaD spectrum dementia. These data underscore the need to better understand the threshold at which leukoaraiosis affects and alters the phenotypic expression in insidious onset dementia syndromes. PMID:22843264

  8. Reconfigurable Solid-state Dye-doped Polymer Ring Resonator Lasers.

    PubMed

    Chandrahalim, Hengky; Fan, Xudong

    2015-12-17

    This paper presents wavelength configurable on-chip solid-state ring lasers fabricated by a single-mask standard lithography. The single- and coupled-ring resonator hosts were fabricated on a fused-silica wafer and filled with 3,3'-Diethyloxacarbocyanine iodide (CY3), Rhodamine 6G (R6G), and 3,3'-Diethylthiadicarbocyanine iodide (CY5)-doped polymer as the reconfigurable gain media. The recorded lasing threshold was ~220 nJ/mm(2) per pulse for the single-ring resonator laser with R6G, marking the lowest threshold shown by solid-state dye-doped polymer lasers fabricated with a standard lithography process on a chip. A single-mode lasing from a coupled-ring resonator system with the lasing threshold of ~360 nJ/mm(2) per pulse was also demonstrated through the Vernier effect. The renewability of the dye-doped polymer was examined by removing and redepositing the dye-doped polymer on the same resonator hosts for multiple cycles. We recorded consistent emissions from the devices for all trials, suggesting the feasibility of employing this technology for numerous photonic and biochemical sensing applications that entail for sustainable, reconfigurable, and low lasing threshold coherent light sources on a chip.

  9. Frequency-tuning characteristics of cervical and ocular vestibular evoked myogenic potentials induced by air-conducted tone bursts.

    PubMed

    Park, Hong Ju; Lee, In-Sik; Shin, Jung Eun; Lee, Yeo Jin; Park, Mun Su

    2010-01-01

    To better characterize both ocular and cervical vestibular evoked myogenic potentials (VEMP) responses at different frequencies of sound in 20 normal subjects. Cervical and ocular VEMPs were recorded. The intensities of sound stimulation decreased from the maximal intensity, until no responses were evoked. Thresholds, amplitudes, latencies and interaural amplitude difference ratio (IADR) at the maximal stimulation were calculated. Both tests showed the similar frequency tuning, with the lowest threshold and highest amplitude for 500-Hz tone-burst stimuli. Sound stimulation at 500Hz showed the response rates of 100% in both tests. Cervical VEMPs showed higher incidence than ocular VEMPs. Ocular VEMP thresholds were significantly higher than those of cervical VEMP. Cervical VEMP amplitudes were significantly higher than ocular VEMP amplitudes. IADRs of ocular and cervical VEMPs did not differ significantly. Ocular VEMP showed the similar frequency tuning to cervical VEMP. Cervical VEMP responses showed higher incidence, lower thresholds and larger amplitudes than ocular VEMP. Cervical VEMP is a more reliable measure than ocular VEMP, though the results of both tests will be complementary. Five hundred Hertz is the optimal frequency to use. Copyright 2009 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  10. Mechanical and biomechanical analysis of a linear piston design for angular-velocity-based orthotic control.

    PubMed

    Lemaire, Edward D; Samadi, Reza; Goudreau, Louis; Kofman, Jonathan

    2013-01-01

    A linear piston hydraulic angular-velocity-based control knee joint was designed for people with knee-extensor weakness to engage knee-flexion resistance when knee-flexion angular velocity reaches a preset threshold, such as during a stumble, but to otherwise allow free knee motion. During mechanical testing at the lowest angular-velocity threshold, the device engaged within 2 degrees knee flexion and resisted moment loads of over 150 Nm. The device completed 400,000 loading cycles without mechanical failure or wear that would affect function. Gait patterns of nondisabled participants were similar to normal at walking speeds that produced below-threshold knee angular velocities. Fast walking speeds, employed purposely to attain the angular-velocity threshold and cause knee-flexion resistance, reduced maximum knee flexion by approximately 25 degrees but did not lead to unsafe gait patterns in foot ground clearance during swing. In knee collapse tests, the device successfully engaged knee-flexion resistance and stopped knee flexion with peak knee moments of up to 235.6 Nm. The outcomes from this study support the potential for the linear piston hydraulic knee joint in knee and knee-ankle-foot orthoses for people with lower-limb weakness.

  11. Standard deviation index for stimulated Brillouin scattering suppression with different homogeneities.

    PubMed

    Ran, Yang; Su, Rongtao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Si, Lei

    2016-05-10

    We present a new quantitative index of standard deviation to measure the homogeneity of spectral lines in a fiber amplifier system so as to find the relation between the stimulated Brillouin scattering (SBS) threshold and the homogeneity of the corresponding spectral lines. A theoretical model is built and a simulation framework has been established to estimate the SBS threshold when input spectra with different homogeneities are set. In our experiment, by setting the phase modulation voltage to a constant value and the modulation frequency to different values, spectral lines with different homogeneities can be obtained. The experimental results show that the SBS threshold increases negatively with the standard deviation of the modulated spectrum, which is in good agreement with the theoretical results. When the phase modulation voltage is confined to 10 V and the modulation frequency is set to 80 MHz, the standard deviation of the modulated spectrum equals 0.0051, which is the lowest value in our experiment. Thus, at this time, the highest SBS threshold has been achieved. This standard deviation can be a good quantitative index in evaluating the power scaling potential in a fiber amplifier system, which is also a design guideline in suppressing the SBS to a better degree.

  12. Monitoring priority substances, other organic contaminants and heavy metals in a volcanic aquifer from different sources and hydrological processes.

    PubMed

    Estevez, Esmeralda; Cabrera, María del Carmen; Fernández-Vera, Juan Ramón; Molina-Díaz, Antonio; Robles-Molina, José; Palacios-Díaz, María del Pino

    2016-05-01

    Irrigation with reclaimed water (R) is necessary to guarantee the sustainability of semi-arid areas. Results obtained during a two years monitoring network (2009-2011) in Gran Canaria are presented, including the analysis of chemical parameters, N and S isotopes, priority substances (2008/105/EC, 2013/39/EU), other organic contaminants and heavy metals in groundwater and R used to irrigate a golf course. The aims of this work are to evaluate the contamination in a volcanic aquifer, relate the presence of organic contaminants and heavy metals with the hydrogeochemistry and identify pollution sources in the area. No priority substance exceeded the EU thresholds for surface water, although seventeen were detected in R. The most frequent compounds were hexachlorobenzene, chlorpyrifos ethyl, fluorene, phenanthrene and pyrene. These compounds were detected at low concentration, except chlorpyrifos. Chlorpyrifos ethyl, terbuthylazine, diuron, terbutryn, procymidone, atrazine and propazine exceeded the European threshold concentration for pesticides in groundwater (100ngL(-1)). Therefore, the priority substances chlorpyrifos ethyl and diuron must be included in monitoring studies. The priority pesticides chlorfenvinphos and diazinon were always detected in R but rarely in groundwater. Besides, the existence of contaminants not related to the current R irrigation has been identified. Absence of environmental problems related to heavy metals can be expected. The relationship among contaminant presence, hydrogeochemistry, including the stable isotopic prints of δ(18)O, δ(15)N and δ(34)S and preferential recharge paths has been described. The coastal well shows high values of EC, nitrate, a variable chemistry, and 50% of organic contaminants detected above 100ngL(-1). The well located in the recharge area presents a stable hydrochemistry, the lowest value of δ(15)N and the lowest contaminants occurrence. The area is an example of a complex volcanic media with several sources of contaminants such as leakages from septic tanks and sewerage, agriculture practices, irrigation with reclaimed water or urban runoff. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Reduction of the virtual space for coupled-cluster excitation energies of large molecules and embedded systems

    PubMed Central

    Send, Robert; Kaila, Ville R. I.; Sundholm, Dage

    2011-01-01

    We investigate how the reduction of the virtual space affects coupled-cluster excitation energies at the approximate singles and doubles coupled-cluster level (CC2). In this reduced-virtual-space (RVS) approach, all virtual orbitals above a certain energy threshold are omitted in the correlation calculation. The effects of the RVS approach are assessed by calculations on the two lowest excitation energies of 11 biochromophores using different sizes of the virtual space. Our set of biochromophores consists of common model systems for the chromophores of the photoactive yellow protein, the green fluorescent protein, and rhodopsin. The RVS calculations show that most of the high-lying virtual orbitals can be neglected without significantly affecting the accuracy of the obtained excitation energies. Omitting all virtual orbitals above 50 eV in the correlation calculation introduces errors in the excitation energies that are smaller than 0.1 eV . By using a RVS energy threshold of 50 eV , the CC2 calculations using triple-ζ basis sets (TZVP) on protonated Schiff base retinal are accelerated by a factor of 6. We demonstrate the applicability of the RVS approach by performing CC2∕TZVP calculations on the lowest singlet excitation energy of a rhodopsin model consisting of 165 atoms using RVS thresholds between 20 eV and 120 eV. The calculations on the rhodopsin model show that the RVS errors determined in the gas-phase are a very good approximation to the RVS errors in the protein environment. The RVS approach thus renders purely quantum mechanical treatments of chromophores in protein environments feasible and offers an ab initio alternative to quantum mechanics∕molecular mechanics separation schemes. PMID:21663351

  14. Amplified spontaneous emission of pyranyliden derivatives in PVK matrix

    NASA Astrophysics Data System (ADS)

    Vembris, Aivars; Zarinsh, Elmars; Kokars, Valdis

    2016-04-01

    One of the well-known red light emitting laser dyes is 4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4Hpyran (DCM). Amplified spontaneous emission (ASE) has been widely investigated of DCM molecules or its derivatives in polymer or low molecular weight matrix. The main issue for these molecules is aggregation which limits doping concentration in matrix. Lowest ASE threshold values within concentration range of 2 and 4 wt% were obtained. In this work ASE properties of two original DCM derivatives in poly(N-vinylcarbazole) (PVK) at various concentrations will be discussed. One of the derivatives is the same DCM dye with replaced butyl groups at electron donor part with bulky trytiloxyethyl groups (DWK-1). These groups do not influence electron transitions in the dye but prevent aggregation of the molecules. Second derivative (DWK-2) consists of two equal donor groups with the attached trytiloxyethyl groups. All results were compared with DCM:PVK system. Photoluminescence quantum yield (PLQY) is almost three times larger for DWK-1 concentration up to 20wt% with respect to DCM systems. PLQY was saturated on 0.06 at higher DWK-1 concentrations. Bulky trytiloxyethyl groups prevent aggregation of the molecules thus decreasing interaction between dyes and numbers of non-radiative decays. Red shift of photoluminescence and amplified spontaneous emission at higher concentrations were observed due to the solid state solvation effect. Increases of dye density in matrix with smaller lose in PLQY resulted in low ASE threshold energy. The lowest threshold value was obtained around 29 μJ/cm2 in DWK-1:PVK films.

  15. Reduction of the virtual space for coupled-cluster excitation energies of large molecules and embedded systems.

    PubMed

    Send, Robert; Kaila, Ville R I; Sundholm, Dage

    2011-06-07

    We investigate how the reduction of the virtual space affects coupled-cluster excitation energies at the approximate singles and doubles coupled-cluster level (CC2). In this reduced-virtual-space (RVS) approach, all virtual orbitals above a certain energy threshold are omitted in the correlation calculation. The effects of the RVS approach are assessed by calculations on the two lowest excitation energies of 11 biochromophores using different sizes of the virtual space. Our set of biochromophores consists of common model systems for the chromophores of the photoactive yellow protein, the green fluorescent protein, and rhodopsin. The RVS calculations show that most of the high-lying virtual orbitals can be neglected without significantly affecting the accuracy of the obtained excitation energies. Omitting all virtual orbitals above 50 eV in the correlation calculation introduces errors in the excitation energies that are smaller than 0.1 eV. By using a RVS energy threshold of 50 eV, the CC2 calculations using triple-ζ basis sets (TZVP) on protonated Schiff base retinal are accelerated by a factor of 6. We demonstrate the applicability of the RVS approach by performing CC2/TZVP calculations on the lowest singlet excitation energy of a rhodopsin model consisting of 165 atoms using RVS thresholds between 20 eV and 120 eV. The calculations on the rhodopsin model show that the RVS errors determined in the gas-phase are a very good approximation to the RVS errors in the protein environment. The RVS approach thus renders purely quantum mechanical treatments of chromophores in protein environments feasible and offers an ab initio alternative to quantum mechanics/molecular mechanics separation schemes. © 2011 American Institute of Physics

  16. INTERNATIONAL CONFERENCE ON SEMICONDUCTOR INJECTION LASERS SELCO-87: Injection lasers based on the AlGaAsSb system emitting at 1.6 μm

    NASA Astrophysics Data System (ADS)

    Virro, A. L.; Eliseev, P. G.; Lyuk, P. A.; Fridental, Ya K.; Khaller, Yu E.

    1988-11-01

    An experimental dependence of the threshold current density jth on the thickness of the active region was used to find the reduced threshold current density for AlGaAsSb (λ = 1.59μm, T = 295K) lasers: this density was 8 kA·cm-2·μm-1. The minimum threshold current was jth = 1.8 kA/cm2. Wide-contact lasers exhibited cw operation down to 175 K.

  17. Threshold current for fireball generation

    NASA Astrophysics Data System (ADS)

    Dijkhuis, Geert C.

    1982-05-01

    Fireball generation from a high-intensity circuit breaker arc is interpreted here as a quantum-mechanical phenomenon caused by severe cooling of electrode material evaporating from contact surfaces. According to the proposed mechanism, quantum effects appear in the arc plasma when the radius of one magnetic flux quantum inside solid electrode material has shrunk to one London penetration length. A formula derived for the threshold discharge current preceding fireball generation is found compatible with data reported by Silberg. This formula predicts linear scaling of the threshold current with the circuit breaker's electrode radius and concentration of conduction electrons.

  18. Placement of implantable cardioverter-defibrillators in paediatric and congenital heart defect patients: a pipeline for model generation and simulation prediction of optimal configurations

    PubMed Central

    Rantner, Lukas J; Vadakkumpadan, Fijoy; Spevak, Philip J; Crosson, Jane E; Trayanova, Natalia A

    2013-01-01

    There is currently no reliable way of predicting the optimal implantable cardioverter-defibrillator (ICD) placement in paediatric and congenital heart defect (CHD) patients. This study aimed to: (1) develop a new image processing pipeline for constructing patient-specific heart–torso models from clinical magnetic resonance images (MRIs); (2) use the pipeline to determine the optimal ICD configuration in a paediatric tricuspid valve atresia patient; (3) establish whether the widely used criterion of shock-induced extracellular potential (Φe) gradients ≥5 V cm−1 in ≥95% of ventricular volume predicts defibrillation success. A biophysically detailed heart–torso model was generated from patient MRIs. Because transvenous access was impossible, three subcutaneous and three epicardial lead placement sites were identified along with five ICD scan locations. Ventricular fibrillation was induced, and defibrillation shocks were applied from 11 ICD configurations to determine defibrillation thresholds (DFTs). Two configurations with epicardial leads resulted in the lowest DFTs overall and were thus considered optimal. Three configurations shared the lowest DFT among subcutaneous lead ICDs. The Φe gradient criterion was an inadequate predictor of defibrillation success, as defibrillation failed in numerous instances even when 100% of the myocardium experienced such gradients. In conclusion, we have developed a new image processing pipeline and applied it to a CHD patient to construct the first active heart–torso model from clinical MRIs. PMID:23798492

  19. High efficiency low threshold current 1.3 μm InAs quantum dot lasers on on-axis (001) GaP/Si

    NASA Astrophysics Data System (ADS)

    Jung, Daehwan; Norman, Justin; Kennedy, M. J.; Shang, Chen; Shin, Bongki; Wan, Yating; Gossard, Arthur C.; Bowers, John E.

    2017-09-01

    We demonstrate highly efficient, low threshold InAs quantum dot lasers epitaxially grown on on-axis (001) GaP/Si substrates using molecular beam epitaxy. Electron channeling contrast imaging measurements show a threading dislocation density of 7.3 × 106 cm-2 from an optimized GaAs template grown on GaP/Si. The high-quality GaAs templates enable as-cleaved quantum dot lasers to achieve a room-temperature continuous-wave (CW) threshold current of 9.5 mA, a threshold current density as low as 132 A/cm2, a single-side output power of 175 mW, and a wall-plug-efficiency of 38.4% at room temperature. As-cleaved QD lasers show ground-state CW lasing up to 80 °C. The application of a 95% high-reflectivity coating on one laser facet results in a CW threshold current of 6.7 mA, which is a record-low value for any kind of Fabry-Perot laser grown on Si.

  20. InAs-based interband-cascade-lasers emitting around 7 μm with threshold current densities below 1 kA/cm{sup 2} at room temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dallner, Matthias; Hau, Florian; Kamp, Martin

    2015-01-26

    Interband cascade lasers (ICLs) grown on InAs substrates with threshold current densities below 1 kA/cm{sup 2} are presented. Two cascade designs with different lengths of the electron injector were investigated. Using a cascade design with 3 InAs quantum wells (QWs) in the electron injector, a device incorporating 22 stages in the active region exhibited a threshold current density of 940 A/cm{sup 2} at a record wavelength of 7 μm for ICLs operating in pulsed mode at room temperature. By investigating the influence of the number of stages on the device performance for a cascade design with 2 QWs in the electron injector, amore » further reduction of the threshold current density to 800 A/cm{sup 2} was achieved for a 30 stage device.« less

  1. Ultralow threshold graded-index separate-confinement heterostructure single quantum well (Al, Ga) As lasers

    NASA Technical Reports Server (NTRS)

    Derry, P. L.; Chen, H. Z.; Morkoc, H.; Yariv, A.; Lau, K. Y.

    1988-01-01

    Broad area graded-index separate-confinement heterostructure single quantum well lasers grown by molecular-beam epitaxy (MBE) with threshold current density as low as 93 A/sq cm (520 microns long) have been fabricated. Buried lasers formed from similarly structured MBE material with liquid phase epitaxy regrowth had threshold currents at submilliampere levels when high reflectivity coatings were applied to the end facets. A CW threshold current of 0.55 mA was obtained for a laser with facet reflectivities of about 80 percent, a cavity length of 120 micron, and an active region stripe width of 1 micron. These devices driven directly with logic level signals have switch-on delays less than 50 ps without any current prebias. Such lasers permit fully on-off switching while at the same time obviating the need for bias monitoring and feedback control.

  2. Active-Matrix Organic Light Emission Diode Pixel Circuit for Suppressing and Compensating for the Threshold Voltage Degradation of Hydrogenated Amorphous Silicon Thin Film Transistors

    NASA Astrophysics Data System (ADS)

    Shin, Hee-Sun; Lee, Won-Kyu; Park, Sang-Guen; Kuk, Seung-Hee; Han, Min-Koo

    2009-03-01

    A new hydrogenated amorphous silicon (a-Si:H) thin film transistor (TFT) pixel circuit for active-matrix organic light emission diodes (AM-OLEDs), which significantly compensates the OLED current degradation by memorizing the threshold voltage of driving TFT and suppresses the threshold voltage shift of a-Si:H TFTs by negative bias annealing, is proposed and fabricated. During the first half of each frame, the driving TFT of the proposed pixel circuit supplies current to the OLED, which is determined by modified data voltage in the compensation scheme. The proposed pixel circuit was able to compensate the threshold voltage shift of the driving TFT as well as the OLED. During the remaining half of each frame, the proposed pixel circuit induces the recovery of the threshold voltage degradation of a-Si:H TFTs owing to the negative bias annealing. The experimental results show that the proposed pixel circuit was able to successfully compensate for the OLED current degradation and suppress the threshold voltage degradation of the driving TFT.

  3. Evaluation and comparison of 50 Hz current threshold of electrocutaneous sensations using different methods

    PubMed Central

    Lindenblatt, G.; Silny, J.

    2006-01-01

    Leakage currents, tiny currents flowing from an everyday-life appliance through the body to the ground, can cause a non-adequate perception (called electrocutaneous sensation, ECS) or even pain and should be avoided. Safety standards for low-frequency range are based on experimental results of current thresholds of electrocutaneous sensations, which however show a wide range between about 50 μA (rms) and 1000 μA (rms). In order to be able to explain these differences, the perception threshold was measured repeatedly in experiments with test persons under identical experimental setup, but by means of different methods (measuring strategies), namely: direct adjustment, classical threshold as amperage of 50% perception probability, and confidence rating procedure of signal detection theory. The current is injected using a 1 cm2 electrode at the highly touch sensitive part of the index fingertip. These investigations show for the first time that the threshold of electrocutaneous sensations is influenced both by adaptation to the non-adequate stimulus and individual, emotional factors. Therefore, classical methods, on which the majority of the safety investigations are based, cannot be used to determine a leakage current threshold. The confidence rating procedure of the modern signal detection theory yields a value of 179.5 μA (rms) at 50 Hz power supply net frequency as the lower end of the 95% confidence range considering the variance in the investigated group. This value is expected to be free of adaptation influences, and is distinctly lower than the European limits and supports the stricter regulations of Canada and USA. PMID:17111461

  4. Mouse current vocalization threshold measured with a neurospecific nociception assay: The effect of sex, morphine, and isoflurane

    PubMed Central

    Spornick, Nicholas; Guptill, Virginia; Koziol, Deloris; Wesley, Robert; Finkel, Julia; Quezado, Zenaide M.N.

    2012-01-01

    Sine-wave electrical stimulation at frequencies 2000, 250, and 5 Hz to respectively evaluate Aβ, Aδ, and C sensory neurons has recently been added to the armamentarium used to evaluate sensory neurons. We developed an automated nociception assay using sine-wave stimulation methodology to determine current vocalization threshold in response to 2000, 250, and 5 Hz and examine the effects of sex, analgesics, and anesthetics in mice. At baseline, males had significantly higher mean current vocalization thresholds compared with female mice at 2000, 250, and 5 Hz (p ≤ 0.019). By 1 h after intrathecal injections of morphine there were significant increases in current vocalization threshold percent changes from baseline that varied with doses (p = 0.0001) and frequency used (p < 0.0001). Specifically, with increasing doses of morphine, there were significantly greater increases in current vocalization threshold percent changes from baseline in response to 5 Hz compared with 250 and 2000 Hz stimulation in a significantly ordered pattern: 5 Hz > 250 Hz (p < 0.0001) and 250 Hz > 2000 Hz (p = 0.0002). Forty-five minutes after exposure, there were no effects of isoflurane on current vocalization thresholds at any frequency. Therefore, our findings suggest that this automated nociception assay using sine-wave stimulation in mice, can be valuable for measurements of the effects of sex, opioids, and anesthetics on the response to electrical stimuli that preferentially stimulate Aβ, Aδ, and C-sensory fibers in vivo. This investigation suggests the validation of this assay and supports its use to examine mechanisms of nociception in mice. PMID:21864576

  5. Thresholds of Toxicological Concern for cosmetics-related substances: New database, thresholds, and enrichment of chemical space.

    PubMed

    Yang, Chihae; Barlow, Susan M; Muldoon Jacobs, Kristi L; Vitcheva, Vessela; Boobis, Alan R; Felter, Susan P; Arvidson, Kirk B; Keller, Detlef; Cronin, Mark T D; Enoch, Steven; Worth, Andrew; Hollnagel, Heli M

    2017-11-01

    A new dataset of cosmetics-related chemicals for the Threshold of Toxicological Concern (TTC) approach has been compiled, comprising 552 chemicals with 219, 40, and 293 chemicals in Cramer Classes I, II, and III, respectively. Data were integrated and curated to create a database of No-/Lowest-Observed-Adverse-Effect Level (NOAEL/LOAEL) values, from which the final COSMOS TTC dataset was developed. Criteria for study inclusion and NOAEL decisions were defined, and rigorous quality control was performed for study details and assignment of Cramer classes. From the final COSMOS TTC dataset, human exposure thresholds of 42 and 7.9 μg/kg-bw/day were derived for Cramer Classes I and III, respectively. The size of Cramer Class II was insufficient for derivation of a TTC value. The COSMOS TTC dataset was then federated with the dataset of Munro and colleagues, previously published in 1996, after updating the latter using the quality control processes for this project. This federated dataset expands the chemical space and provides more robust thresholds. The 966 substances in the federated database comprise 245, 49 and 672 chemicals in Cramer Classes I, II and III, respectively. The corresponding TTC values of 46, 6.2 and 2.3 μg/kg-bw/day are broadly similar to those of the original Munro dataset. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Formant-frequency discrimination of synthesized vowels in budgerigars (Melopsittacus undulatus) and humans.

    PubMed

    Henry, Kenneth S; Amburgey, Kassidy N; Abrams, Kristina S; Idrobo, Fabio; Carney, Laurel H

    2017-10-01

    Vowels are complex sounds with four to five spectral peaks known as formants. The frequencies of the two lowest formants, F1and F2, are sufficient for vowel discrimination. Behavioral studies show that many birds and mammals can discriminate vowels. However, few studies have quantified thresholds for formant-frequency discrimination. The present study examined formant-frequency discrimination in budgerigars (Melopsittacus undulatus) and humans using stimuli with one or two formants and a constant fundamental frequency of 200 Hz. Stimuli had spectral envelopes similar to natural speech and were presented with random level variation. Thresholds were estimated for frequency discrimination of F1, F2, and simultaneous F1 and F2 changes. The same two-down, one-up tracking procedure and single-interval, two-alternative task were used for both species. Formant-frequency discrimination thresholds were as sensitive in budgerigars as in humans and followed the same patterns across all conditions. Thresholds expressed as percent frequency difference were higher for F1 than for F2, and were unchanged between stimuli with one or two formants. Thresholds for simultaneous F1 and F2 changes indicated that discrimination was based on combined information from both formant regions. Results were consistent with previous human studies and show that budgerigars provide an exceptionally sensitive animal model of vowel feature discrimination.

  7. Monte Carlo simulation of energy deposition by low-energy electrons in molecular hydrogen

    NASA Technical Reports Server (NTRS)

    Heaps, M. G.; Furman, D. R.; Green, A. E. S.

    1975-01-01

    A set of detailed atomic cross sections has been used to obtain the spatial deposition of energy by 1-20-eV electrons in molecular hydrogen by a Monte Carlo simulation of the actual trajectories. The energy deposition curve (energy per distance traversed) is quite peaked in the forward direction about the entry point for electrons with energies above the threshold of the electronic states, but the peak decreases and broadens noticeably as the electron energy decreases below 10 eV (threshold for the lowest excitable electronic state of H2). The curve also assumes a very symmetrical shape for energies below 10 eV, indicating the increasing importance of elastic collisions in determining the shape of the curve, although not the mode of energy deposition.

  8. Blister formation at subcritical doses in tungsten irradiated by MeV protons

    NASA Astrophysics Data System (ADS)

    Gavish Segev, I.; Yahel, E.; Silverman, I.; Makov, G.

    2017-12-01

    The material response of tungsten to irradiation by MeV protons has been studied experimentally, in particular with respect to bubble and blister formation. Tungsten samples were irradiated by 2.2 MeV protons at the Soreq Applied Research Accelerator Facility (SARAF) to doses of the order of 1017 protons/cm2 which are below the reported critical threshold for blister formation derived from keV range irradiation studies. Large, well-developed blisters are observed indicating that for MeV range protons the critical threshold is at least an order of magnitude lower than the lowest value reported previously. The effects of fluence, flux, and corresponding temperature on the distribution and characteristics of the obtained blisters were studied. FIB cross sections of several blisters exposed their depth and structure.

  9. Multivariate Analyses of Balance Test Performance, Vestibular Thresholds, and Age

    PubMed Central

    Karmali, Faisal; Bermúdez Rey, María Carolina; Clark, Torin K.; Wang, Wei; Merfeld, Daniel M.

    2017-01-01

    We previously published vestibular perceptual thresholds and performance in the Modified Romberg Test of Standing Balance in 105 healthy humans ranging from ages 18 to 80 (1). Self-motion thresholds in the dark included roll tilt about an earth-horizontal axis at 0.2 and 1 Hz, yaw rotation about an earth-vertical axis at 1 Hz, y-translation (interaural/lateral) at 1 Hz, and z-translation (vertical) at 1 Hz. In this study, we focus on multiple variable analyses not reported in the earlier study. Specifically, we investigate correlations (1) among the five thresholds measured and (2) between thresholds, age, and the chance of failing condition 4 of the balance test, which increases vestibular reliance by having subjects stand on foam with eyes closed. We found moderate correlations (0.30–0.51) between vestibular thresholds for different motions, both before and after using our published aging regression to remove age effects. We found that lower or higher thresholds across all threshold measures are an individual trait that account for about 60% of the variation in the population. This can be further distributed into two components with about 20% of the variation explained by aging and 40% of variation explained by a single principal component that includes similar contributions from all threshold measures. When only roll tilt 0.2 Hz thresholds and age were analyzed together, we found that the chance of failing condition 4 depends significantly on both (p = 0.006 and p = 0.013, respectively). An analysis incorporating more variables found that the chance of failing condition 4 depended significantly only on roll tilt 0.2 Hz thresholds (p = 0.046) and not age (p = 0.10), sex nor any of the other four threshold measures, suggesting that some of the age effect might be captured by the fact that vestibular thresholds increase with age. For example, at 60 years of age, the chance of failing is roughly 5% for the lowest roll tilt thresholds in our population, but this increases to 80% for the highest roll tilt thresholds. These findings demonstrate the importance of roll tilt vestibular cues for balance, even in individuals reporting no vestibular symptoms and with no evidence of vestibular dysfunction. PMID:29167656

  10. A THRESHOLD ANALYSIS OF THE TUNNEL INJECTION LASER.

    DTIC Science & Technology

    A new threshold analysis of the tunnel injection laser is given that differs from previous treatments in that an additional loss mechanism is...a slight increase in the threshold current density of the tunnel laser. For a device one millimeter long composed of GaAs at 77K, the threshold

  11. [Alpha-1 antitrypsin deficiency. The experience of Pulido Valente Hospital with augmentation therapy].

    PubMed

    Alves Costa, Carla; Santos, Cristina

    2009-01-01

    Alpha-1 antitrypsin (AAT) is synthesised in the liver and has half-life of 4-5 days. AAT has antiprotease activity, with particular affinity for neutrophil elastase. Its deficiency leads to a lack of effective lung protection against activated neutrophil enzymes. Deficiency of AAT is a genetic disorder that occurs as a result of the inheritance of two protease inhibitor deficient alleles. Of the deficient alleles, Pi*Z is the most common, and the homozygous form Pi*ZZ results in the lowest serum levels, usually below 50 mg/ dl. The "protective threshold" is 80 mg/dl. Smoking increases the risk of emphysema. The current goal of augmentation therapy is to raise the plasma levels, above protective threshold and slow disease progression. The authors present the experience of the Day Care Hospital of the Pulido Valente Hospital with five male patients presenting emphysema due to AAT deficiency, receiving weekly intravenous treatment with Prolastin. We performed a clinical, respiratory functional and radiological evaluation between 2003 and 2007. The results point to a slower progression of the disease, with clinical and radiological stability and a reduced rate of FEV1 decline. Augmentation therapy is an expensive treatment and its use is lacking supportive evidence of efficacy by randomized controlled clinical trials. Evidence that it confers benefits is based on observational studies. Our experience is positive, showing clinical, radiological and functional benefits. The literature available points to a decrease in mortality, but we could not affirm so in our small population.

  12. High power single mode 980 nm AlGaInAs/AlGaAs quantum well lasers with a very low threshold current

    NASA Astrophysics Data System (ADS)

    Zhen, Dong; Cuiluan, Wang; Hongqi, Jing; Suping, Liu; Xiaoyu, Ma

    2013-11-01

    To achieve low threshold current as well as high single mode output power, a graded index separate confinement heterostructure (GRIN-SCH) AlGaInAs/AlGaAs quantum well laser with an optimized ridge waveguide was fabricated. The threshold current was reduced to 8 mA. An output power of 76 mW was achieved at 100 mA current at room temperature, with a slope efficiency of 0.83 W/A and a horizon divergent angle of 6.3°. The maximum single mode output power of the device reached as high as 450 mW.

  13. Constant-current regulator improves tunnel diode threshold-detector performance

    NASA Technical Reports Server (NTRS)

    Cancro, C. A.

    1965-01-01

    Grounded-base transistor is placed in a tunnel diode threshold detector circuit, and a bias voltage is applied to the tunnel diode. This provides the threshold detector with maximum voltage output and overload protection.

  14. Why do adults with dyslexia have poor global motion sensitivity?

    PubMed

    Conlon, Elizabeth G; Lilleskaret, Gry; Wright, Craig M; Stuksrud, Anne

    2013-01-01

    Two experiments aimed to determine why adults with dyslexia have higher global motion thresholds than typically reading controls. In Experiment 1, the dot density and number of animation frames presented in the dot stimulus were manipulated because of findings that use of a high dot density can normalize coherence thresholds in individuals with dyslexia. Dot densities were 14.15 and 3.54 dots/deg(2). These were presented for five (84 ms) or eight (134 ms) frames. The dyslexia group had higher coherence thresholds in all conditions than controls. However, in the high dot density, long duration condition, both reader groups had the lowest thresholds indicating normal temporal recruitment. These results indicated that the dyslexia group could sample the additional signals dots over space and then integrate these with the same efficiency as controls. In Experiment 2, we determined whether briefly presenting a fully coherent prime moving in either the same or opposite direction of motion to a partially coherent test stimulus would systematically increase and decrease global motion thresholds in the reader groups. When the direction of motion in the prime and test was the same, global motion thresholds increased for both reader groups. The increase in coherence thresholds was significantly greater for the dyslexia group. When the motion of the prime and test were presented in opposite directions, coherence thresholds were reduced in both groups. No group threshold differences were found. We concluded that the global motion processing deficit found in adults with dyslexia can be explained by undersampling of the target motion signals. This might occur because of difficulties directing attention to the relevant motion signals in the random dot pattern, and not a specific difficulty integrating global motion signals. These effects are most likely to occur in the group with dyslexia when more complex computational processes are required to process global motion.

  15. Why do adults with dyslexia have poor global motion sensitivity?

    PubMed Central

    Conlon, Elizabeth G.; Lilleskaret, Gry; Wright, Craig M.; Stuksrud, Anne

    2013-01-01

    Two experiments aimed to determine why adults with dyslexia have higher global motion thresholds than typically reading controls. In Experiment 1, the dot density and number of animation frames presented in the dot stimulus were manipulated because of findings that use of a high dot density can normalize coherence thresholds in individuals with dyslexia. Dot densities were 14.15 and 3.54 dots/deg2. These were presented for five (84 ms) or eight (134 ms) frames. The dyslexia group had higher coherence thresholds in all conditions than controls. However, in the high dot density, long duration condition, both reader groups had the lowest thresholds indicating normal temporal recruitment. These results indicated that the dyslexia group could sample the additional signals dots over space and then integrate these with the same efficiency as controls. In Experiment 2, we determined whether briefly presenting a fully coherent prime moving in either the same or opposite direction of motion to a partially coherent test stimulus would systematically increase and decrease global motion thresholds in the reader groups. When the direction of motion in the prime and test was the same, global motion thresholds increased for both reader groups. The increase in coherence thresholds was significantly greater for the dyslexia group. When the motion of the prime and test were presented in opposite directions, coherence thresholds were reduced in both groups. No group threshold differences were found. We concluded that the global motion processing deficit found in adults with dyslexia can be explained by undersampling of the target motion signals. This might occur because of difficulties directing attention to the relevant motion signals in the random dot pattern, and not a specific difficulty integrating global motion signals. These effects are most likely to occur in the group with dyslexia when more complex computational processes are required to process global motion. PMID:24376414

  16. Income (In-) Adequacy? The Official Poverty Line, Possible Changes, and Some Historical Lessons.

    ERIC Educational Resources Information Center

    Fisher, Gordon

    1999-01-01

    Examines the current official poverty thresholds (including Orshansky's thresholds) and the possibility that a new poverty measure may be adopted soon, discussing the thresholds from a historical perspective. Lessons drawn from the history of poverty thresholds and of early unofficial poverty lines in the United States are included. Recent…

  17. Effect of transcranial direct current stimulation on vestibular-ocular and vestibulo-perceptual thresholds.

    PubMed

    Kyriakareli, Artemis; Cousins, Sian; Pettorossi, Vito E; Bronstein, Adolfo M

    2013-10-02

    Transcranial direct current stimulation (tDCS) was used in 17 normal individuals to modulate vestibulo-ocular reflex (VOR) and self-motion perception rotational thresholds. The electrodes were applied over the temporoparietal junction bilaterally. Both vestibular nystagmic and perceptual thresholds were increased during as well as after tDCS stimulation. Body rotation was labeled as ipsilateral or contralateral to the anode side, but no difference was observed depending on the direction of rotation or hemisphere polarity. Threshold increase during tDCS was greater for VOR than for motion perception. 'Sham' stimulation had no effect on thresholds. We conclude that tDCS produces an immediate and sustained depression of cortical regions controlling VOR and movement perception. Temporoparietal areas appear to be involved in vestibular threshold modulation but the differential effects observed between VOR and perception suggest a partial dissociation between cortical processing of reflexive and perceptual responses.

  18. Transverse tripolar stimulation of peripheral nerve: a modelling study of spatial selectivity.

    PubMed

    Deurloo, K E; Holsheimer, J; Boom, H B

    1998-01-01

    Various anode-cathode configurations in a nerve cuff are modelled to predict their spatial selectivity characteristics for functional nerve stimulation. A 3D volume conductor model of a monofascicular nerve is used for the computation of stimulation-induced field potentials, whereas a cable model of myelinated nerve fibre is used for the calculation of the excitation thresholds of fibres. As well as the usual configurations (monopole, bipole, longitudinal tripole, 'steering' anode), a transverse tripolar configuration (central cathode) is examined. It is found that the transverse tripole is the only configuration giving convex recruitment contours and therefore maximises activation selectivity for a small (cylindrical) bundle of fibres in the periphery of a monofascicular nerve trunk. As the electrode configuration is changed to achieve greater selectivity, the threshold current increases. Therefore threshold currents for fibre excitation with a transverse tripole are relatively high. Inverse recruitment is less extreme than for the other configurations. The influences of several geometrical parameters and model conductivities of the transverse tripole on selectivity and threshold current are analysed. In chronic implantation, when electrodes are encapsulated by a layer of fibrous tissue, threshold currents are low, whereas the shape of the recruitment contours in transverse tripolar stimulation does not change.

  19. Low-threshold high-T/0/ constricted double heterojunction AlGaAs diode lasers

    NASA Technical Reports Server (NTRS)

    Botez, D.; Connolly, J. C.

    1980-01-01

    Constricted double heterojunction diode lasers of relatively low CW thresholds (28-40 mA) are obtained by growing structures that maximize the amount of current flow into the lasing spot. These values are obtained while still using standard 10 microns wide oxide-defined stripe contacts. Over the 20-70 C temperature interval, threshold current temperature coefficients as high as 320 C and a virtually constant external differential quantum efficiency, are found.

  20. Vestibular evoked myogenic potential (VEMP) in patients with Ménière's disease with drop attacks.

    PubMed

    Timmer, Ferdinand C A; Zhou, Guangwei; Guinan, John J; Kujawa, Sharon G; Herrmann, Barbara S; Rauch, Steven D

    2006-05-01

    In this retrospective study, we tested the hypothesis that vestibular evoked myogenic potential (VEMP) thresholds are more often elevated or absent in patients with Ménière's disease experiencing Tumarkin drop attacks than in other patients with Ménière's disease. Subjects included normal subjects (n = 14) and patients with unilateral Ménière's disease by AAO-HNS (1995) diagnostic criteria with (n = 12) and without (n = 82) Tumarkin drop attacks at a large specialty hospital otology service. VEMP threshold testing was conducted using 250, 500, and 1,000 Hz tone burst stimuli. VEMP responses were present in at all frequencies in both ears of all normal subjects. In unaffected ears of patients with unilateral Ménière's disease, VEMPs were undetectable in 13% of measurements attempted. This number rose to 18% in affected ears of patients with unilateral Ménière's disease and to 41% in Meniere ears with Tumarkin drop attacks. Frequency tuning of the VEMP response in normal subjects showed lowest thresholds at 500 Hz. In Meniere ears, the tuning was altered such that the 500-Hz thresholds were higher than the 1,000-Hz thresholds. There was a gradient of threshold elevation and altered tuning that corresponded to the gradient of worsening disease. Our findings support the hypothesis that Tumarkin drop attacks arise from advanced disease involving the saccule and that VEMP may be a clinically valuable metric of disease severity or progression in patients with Ménière's disease.

  1. Investigation of Adaptive-threshold Approaches for Determining Area-Time Integrals from Satellite Infrared Data to Estimate Convective Rain Volumes

    NASA Technical Reports Server (NTRS)

    Smith, Paul L.; VonderHaar, Thomas H.

    1996-01-01

    The principal goal of this project is to establish relationships that would allow application of area-time integral (ATI) calculations based upon satellite data to estimate rainfall volumes. The research is being carried out as a collaborative effort between the two participating organizations, with the satellite data analysis to determine values for the ATIs being done primarily by the STC-METSAT scientists and the associated radar data analysis to determine the 'ground-truth' rainfall estimates being done primarily at the South Dakota School of Mines and Technology (SDSM&T). Synthesis of the two separate kinds of data and investigation of the resulting rainfall-versus-ATI relationships is then carried out jointly. The research has been pursued using two different approaches, which for convenience can be designated as the 'fixed-threshold approach' and the 'adaptive-threshold approach'. In the former, an attempt is made to determine a single temperature threshold in the satellite infrared data that would yield ATI values for identifiable cloud clusters which are closely related to the corresponding rainfall amounts as determined by radar. Work on the second, or 'adaptive-threshold', approach for determining the satellite ATI values has explored two avenues: (1) attempt involved choosing IR thresholds to match the satellite ATI values with ones separately calculated from the radar data on a case basis; and (2) an attempt involved a striaghtforward screening analysis to determine the (fixed) offset that would lead to the strongest correlation and lowest standard error of estimate in the relationship between the satellite ATI values and the corresponding rainfall volumes.

  2. SONOS Nonvolatile Memory Cell Programming Characteristics

    NASA Technical Reports Server (NTRS)

    MacLeod, Todd C.; Phillips, Thomas A.; Ho, Fat D.

    2010-01-01

    Silicon-oxide-nitride-oxide-silicon (SONOS) nonvolatile memory is gaining favor over conventional EEPROM FLASH memory technology. This paper characterizes the SONOS write operation using a nonquasi-static MOSFET model. This includes floating gate charge and voltage characteristics as well as tunneling current, voltage threshold and drain current characterization. The characterization of the SONOS memory cell predicted by the model closely agrees with experimental data obtained from actual SONOS memory cells. The tunnel current, drain current, threshold voltage and read drain current all closely agreed with empirical data.

  3. A comparison of auditory brainstem responses across diving bird species

    USGS Publications Warehouse

    Crowell, Sara E.; Berlin, Alicia; Carr, Catherine E.; Olsen, Glenn H.; Therrien, Ronald E.; Yannuzzi, Sally E.; Ketten, Darlene R.

    2015-01-01

    There is little biological data available for diving birds because many live in hard-to-study, remote habitats. Only one species of diving bird, the black-footed penguin (Spheniscus demersus), has been studied in respect to auditory capabilities (Wever et al., Proc Natl Acad Sci USA 63:676–680, 1969). We, therefore, measured in-air auditory threshold in ten species of diving birds, using the auditory brainstem response (ABR). The average audiogram obtained for each species followed the U-shape typical of birds and many other animals. All species tested shared a common region of the greatest sensitivity, from 1000 to 3000 Hz, although audiograms differed significantly across species. Thresholds of all duck species tested were more similar to each other than to the two non-duck species tested. The red-throated loon (Gavia stellata) and northern gannet (Morus bassanus) exhibited the highest thresholds while the lowest thresholds belonged to the duck species, specifically the lesser scaup (Aythya affinis) and ruddy duck (Oxyura jamaicensis). Vocalization parameters were also measured for each species, and showed that with the exception of the common eider (Somateria mollisima), the peak frequency, i.e., frequency at the greatest intensity, of all species' vocalizations measured here fell between 1000 and 3000 Hz, matching the bandwidth of the most sensitive hearing range.

  4. Bumblebees are not deterred by ecologically relevant concentrations of nectar toxins.

    PubMed

    Tiedeken, Erin Jo; Stout, Jane C; Stevenson, Philip C; Wright, Geraldine A

    2014-05-01

    Bees visit flowers to collect nectar and pollen that contain nutrients and simultaneously facilitate plant sexual reproduction. Paradoxically, nectar produced to attract pollinators often contains deterrent or toxic plant compounds associated with herbivore defence. The functional significance of these nectar toxins is not fully understood, but they may have a negative impact on pollinator behaviour and health, and, ultimately, plant pollination. This study investigates whether a generalist bumblebee, Bombus terrestris, can detect naturally occurring concentrations of nectar toxins. Using paired-choice experiments, we identified deterrence thresholds for five compounds found in the nectar of bee-pollinated plants: quinine, caffeine, nicotine, amygdalin and grayanotoxin. The deterrence threshold was determined when bumblebees significantly preferred a sucrose solution over a sucrose solution containing the compound. Bumblebees had the lowest deterrence threshold for the alkaloid quinine (0.01 mmol l(-1)); all other compounds had higher deterrence thresholds, above the natural concentration range in floral nectar. Our data, combined with previous work using honeybees, suggest that generalist bee species have poor acuity for the detection of nectar toxins. The fact that bees do not avoid nectar-relevant concentrations of these compounds likely indicates that it is difficult for them to learn to associate floral traits with the presence of toxins, thus maintaining this trait in plant populations.

  5. A comparison of auditory brainstem responses across diving bird species

    PubMed Central

    Crowell, Sara E.; Wells-Berlin, Alicia M.; Carr, Catherine E.; Olsen, Glenn H.; Therrien, Ronald E.; Yannuzzi, Sally E.; Ketten, Darlene R.

    2015-01-01

    There is little biological data available for diving birds because many live in hard-to-study, remote habitats. Only one species of diving bird, the black-footed penguin (Spheniscus demersus), has been studied in respect to auditory capabilities (Wever et al. 1969). We therefore measured in-air auditory threshold in ten species of diving birds, using the auditory brainstem response (ABR). The average audiogram obtained for each species followed the U-shape typical of birds and many other animals. All species tested shared a common region of greatest sensitivity, from 1000 to 3000 Hz, although audiograms differed significantly across species. Thresholds of all duck species tested were more similar to each other than to the two non-duck species tested. The red-throated loon (Gavia stellata) and northern gannet (Morus bassanus) exhibited the highest thresholds while the lowest thresholds belonged to the duck species, specifically the lesser scaup (Aythya affinis) and ruddy duck (Oxyura jamaicensis). Vocalization parameters were also measured for each species, and showed that with the exception of the common eider (Somateria mollisima), the peak frequency, i.e. frequency at the greatest intensity, of all species’ vocalizations measured here fell between 1000 and 3000 Hz, matching the bandwidth of the most sensitive hearing range. PMID:26156644

  6. Degenerate band edge laser

    NASA Astrophysics Data System (ADS)

    Veysi, Mehdi; Othman, Mohamed A. K.; Figotin, Alexander; Capolino, Filippo

    2018-05-01

    We propose a class of lasers based on a fourth-order exceptional point of degeneracy (EPD) referred to as the degenerate band edge (DBE). EPDs have been found in parity-time-symmetric photonic structures that require loss and/or gain; here we show that the DBE is a different kind of EPD since it occurs in periodic structures that are lossless and gainless. Because of this property, a small level of gain is sufficient to induce single-frequency lasing based on a synchronous operation of four degenerate Floquet-Bloch eigenwaves. This lasing scheme constitutes a light-matter interaction mechanism that leads also to a unique scaling law of the laser threshold with the inverse of the fifth power of the laser-cavity length. The DBE laser has the lowest lasing threshold in comparison to a regular band edge laser and to a conventional laser in cavities with the same loaded quality (Q ) factor and length. In particular, even without mirror reflectors the DBE laser exhibits a lasing threshold which is an order of magnitude lower than that of a uniform cavity laser of the same length and with very high mirror reflectivity. Importantly, this novel DBE lasing regime enforces mode selectivity and coherent single-frequency operation even for pumping rates well beyond the lasing threshold, in contrast to the multifrequency nature of conventional uniform cavity lasers.

  7. Bumblebees are not deterred by ecologically relevant concentrations of nectar toxins

    PubMed Central

    Tiedeken, Erin Jo; Stout, Jane C.; Stevenson, Philip C.; Wright, Geraldine A.

    2014-01-01

    Bees visit flowers to collect nectar and pollen that contain nutrients and simultaneously facilitate plant sexual reproduction. Paradoxically, nectar produced to attract pollinators often contains deterrent or toxic plant compounds associated with herbivore defence. The functional significance of these nectar toxins is not fully understood, but they may have a negative impact on pollinator behaviour and health, and, ultimately, plant pollination. This study investigates whether a generalist bumblebee, Bombus terrestris, can detect naturally occurring concentrations of nectar toxins. Using paired-choice experiments, we identified deterrence thresholds for five compounds found in the nectar of bee-pollinated plants: quinine, caffeine, nicotine, amygdalin and grayanotoxin. The deterrence threshold was determined when bumblebees significantly preferred a sucrose solution over a sucrose solution containing the compound. Bumblebees had the lowest deterrence threshold for the alkaloid quinine (0.01 mmol l−1); all other compounds had higher deterrence thresholds, above the natural concentration range in floral nectar. Our data, combined with previous work using honeybees, suggest that generalist bee species have poor acuity for the detection of nectar toxins. The fact that bees do not avoid nectar-relevant concentrations of these compounds likely indicates that it is difficult for them to learn to associate floral traits with the presence of toxins, thus maintaining this trait in plant populations. PMID:24526720

  8. Defining thresholds of sustainable impact on benthic communities in relation to fishing disturbance.

    PubMed

    Lambert, G I; Murray, L G; Hiddink, J G; Hinz, H; Lincoln, H; Hold, N; Cambiè, G; Kaiser, M J

    2017-07-14

    While the direct physical impact on seabed biota is well understood, no studies have defined thresholds to inform an ecosystem-based approach to managing fishing impacts. We addressed this knowledge gap using a large-scale experiment that created a controlled gradient of fishing intensity and assessed the immediate impacts and short-term recovery. We observed a mosaic of taxon-specific responses at various thresholds. The lowest threshold of significant lasting impact occurred between 1 and 3 times fished and elicited a decrease in abundance of 39 to 70% for some sessile epifaunal organisms (cnidarians, bryozoans). This contrasted with significant increases in abundance and/or biomass of scavenging species (epifaunal echinoderms, infaunal crustaceans) by two to four-fold in areas fished twice and more. In spite of these significant specific responses, the benthic community structure, biomass and abundance at the population level appeared resilient to fishing. Overall, natural temporal variation in community metrics exceeded the effects of fishing in this highly dynamic study site, suggesting that an acute level of disturbance (fished over six times) would match the level of natural variation. We discuss the implications of our findings for natural resources management with respect to context-specific human disturbance and provide guidance for best fishing practices.

  9. Automatic detection of malaria parasite in blood images using two parameters.

    PubMed

    Kim, Jong-Dae; Nam, Kyeong-Min; Park, Chan-Young; Kim, Yu-Seop; Song, Hye-Jeong

    2015-01-01

    Malaria must be diagnosed quickly and accurately at the initial infection stage and treated early to cure it properly. The malaria diagnosis method using a microscope requires much labor and time of a skilled expert and the diagnosis results vary greatly between individual diagnosticians. Therefore, to be able to measure the malaria parasite infection quickly and accurately, studies have been conducted for automated classification techniques using various parameters. In this study, by measuring classification technique performance according to changes of two parameters, the parameter values were determined that best distinguish normal from plasmodium-infected red blood cells. To reduce the stain deviation of the acquired images, a principal component analysis (PCA) grayscale conversion method was used, and as parameters, we used a malaria infected area and a threshold value used in binarization. The parameter values with the best classification performance were determined by selecting the value (72) corresponding to the lowest error rate on the basis of cell threshold value 128 for the malaria threshold value for detecting plasmodium-infected red blood cells.

  10. Flavour and identification threshold detection overview of Slovak adepts for certified testing.

    PubMed

    Vietoris, VladimIr; Barborova, Petra; Jancovicova, Jana; Eliasova, Lucia; Karvaj, Marian

    2016-07-01

    During certification process of sensory assessors of Slovak certification body we obtained results for basic taste thresholds and lifestyle habits. 500 adult people were screened during experiment with food industry background. For analysis of basic and non basic tastes, we used standardized procedure of ISO 8586-1:1993. In flavour test experiment, group of (26-35 y.o) produced the lowest error ratio (1.438), highest is (56+ y.o.) group with result (2.0). Average error value based on gender for women was (1.510) in comparison to men (1.477). People with allergies have the average error ratio (1.437) in comparison to people without allergies (1.511). Non-smokers produced less errors (1.484) against the smokers (1.576). Another flavour threshold identification test detected differences among age groups (by age are values increased). The highest number of errors made by men in metallic taste was (24%) the same as made by women (22%). Higher error ratio made by men occurred in salty taste (19%) against women (10%). Analysis detected some differences between allergic/non-allergic, smokers/non-smokers groups.

  11. Definition of temperature thresholds: the example of the French heat wave warning system.

    PubMed

    Pascal, Mathilde; Wagner, Vérène; Le Tertre, Alain; Laaidi, Karine; Honoré, Cyrille; Bénichou, Françoise; Beaudeau, Pascal

    2013-01-01

    Heat-related deaths should be somewhat preventable. In France, some prevention measures are activated when minimum and maximum temperatures averaged over three days reach city-specific thresholds. The current thresholds were computed based on a descriptive analysis of past heat waves and on local expert judgement. We tested whether a different method would confirm these thresholds. The study was set in the six cities of Paris, Lyon, Marseille, Nantes, Strasbourg and Limoges between 1973 and 2003. For each city, we estimated the excess in mortality associated with different temperature thresholds, using a generalised additive model, controlling for long-time trends, seasons and days of the week. These models were used to compute the mortality predicted by different percentiles of temperatures. The thresholds were chosen as the percentiles associated with a significant excess mortality. In all cities, there was a good correlation between current thresholds and the thresholds derived from the models, with 0°C to 3°C differences for averaged maximum temperatures. Both set of thresholds were able to anticipate the main periods of excess mortality during the summers of 1973 to 2003. A simple method relying on descriptive analysis and expert judgement is sufficient to define protective temperature thresholds and to prevent heat wave mortality. As temperatures are increasing along with the climate change and adaptation is ongoing, more research is required to understand if and when thresholds should be modified.

  12. Device for monitoring cell voltage

    DOEpatents

    Doepke, Matthias [Garbsen, DE; Eisermann, Henning [Edermissen, DE

    2012-08-21

    A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

  13. Exposure-response relationship and risk assessment for cognitive deficits in early welding-induced manganism.

    PubMed

    Park, Robert M; Bowler, Rosemarie M; Roels, Harry A

    2009-10-01

    The exposure-response relationship for manganese (Mn)-induced adverse nervous system effects is not well described. Symptoms and neuropsychological deficits associated with early manganism were previously reported for welders constructing bridge piers during 2003 to 2004. A reanalysis using improved exposure, work history information, and diverse exposure metrics is presented here. Ten neuropsychological performance measures were examined, including working memory index (WMI), verbal intelligence quotient, design fluency, Stroop color word test, Rey-Osterrieth Complex Figure, and Auditory Consonant Trigram tests. Mn blood levels and air sampling data in the form of both personal and area samples were available. The exposure metrics used were cumulative exposure to Mn, body burden assuming simple first-order kinetics for Mn elimination, and cumulative burden (effective dose). Benchmark doses were calculated. Burden with a half-life of about 150 days was the best predictor of blood Mn. WMI performance declined by 3.6 (normal = 100, SD = 15) for each 1.0 mg/m3 x mo exposure (P = 0.02, one tailed). At the group mean exposure metric (burden; half-life = 275 days), WMI performance was at the lowest 17th percentile of normal, and at the maximum observed metric, performance was at the lowest 2.5 percentiles. Four other outcomes also exhibited statistically significant associations (verbal intelligence quotient, verbal comprehension index, design fluency, Stroop color word test); no dose-rate effect was observed for three of the five outcomes. A risk assessment performed for the five stronger effects, choosing various percentiles of normal performance to represent impairment, identified benchmark doses for a 2-year exposure leading to 5% excess impairment prevalence in the range of 0.03 to 0.15 mg/m3, or 30 to 150 microg/m3, total Mn in air, levels that are far below those permitted by current occupational standards. More than one-third of workers would be impaired after working 2 years at 0.2 mg/m3 Mn (the current threshold limit value).

  14. WE-D-BRA-06: IMRT QA with ArcCHECK: The MD Anderson Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aristophanous, M; Suh, Y; Chi, P

    Purpose: The objective of this project was to report our initial IMRT QA results and experience with the SunNuclear ArcCHECK. Methods: Three thousand one-hundred and sixteen cases were treated with IMRT or VMAT at our institution between October 2013 and September 2014. All IMRT/VMAT treatment plans underwent Quality Assurance (QA) using ArcCHECK prior to therapy. For clinical evaluation, a Gamma analysis is performed following QA delivery using the SNC Patient software (Sun Nuclear Corp) at the 3%/3mm level. QA Gamma pass rates were analyzed based on categories of treatment site, technique, and type of MLCs. Our current clinical threshold formore » passing a QA (Tclin) is set at a Gamma pass rate greater than 90%. We recorded the percent of failures for each category, as well as the Gamma pass rate threshold that would Result in 95% of QAs to pass (T95). Results: Using Tclin a failure rate of 5.9% over all QAs was observed. The highest failure rate was observed for gynecological (22%) and the lowest for CNS (0.9%) treatments. T95 was 91% over all QAs and ranged from 73% (gynecological) to 96.5% (CNS) for individual treatments sites. T95 was lower for IMRT and non-HD (high definition) MLCs at 88.5% and 94.5%, respectively, compared to 92.4% and 97.1% for VMAT and HD MLC treatments, respectively. There was a statistically significant difference between the passing rates for IMRT vs. VMAT and for HD MLCs vs. non-HD MLCs (p-values << 0.01). Gynecological, IMRT, and HD MLC treatments typically include more plans with larger field sizes. Conclusion: On average, Tclin with ArcCHECK was consistent with T95, as well as the 90% action level reported in TG-119. However, significant variations between the examined categories suggest a link between field size and QA passing rates and may warrant field size-specific passing rate thresholds.« less

  15. The generation of O(1S) from the dissociative recombination of O2(+)

    NASA Technical Reports Server (NTRS)

    Guberman, Steven L.; Giusti-Suzor, Annick

    1991-01-01

    The multichannel quantum defect theory (MQDT) method and large scale wave functions are applied to the calculation of the cross sections and rates for dissociative recombination of O2(+) along the 1Sigma-u(+) dissociative potential. Indirect dissociative recombination is accounted for by simultaneously including both the vibronic and electronic coupling to the intermediate Rydberg resonances. An enhanced MQDT approach involving a second-order K matrix is described. Cross sections and rates for the lowest three vibrational levels of the ion are reported. The shapes of the cross sections are discussed in terms of Fano's profile index. It is found that, for each of the three ion vibrational levels, the intermediate Rydberg resonances reduce the dissociative recombination rate below the direct recombination rate. Just above threshold, resonances with centers below threshold play an important role.

  16. Existence of Hartree-Fock excited states for atoms and molecules

    NASA Astrophysics Data System (ADS)

    Lewin, Mathieu

    2018-04-01

    For neutral and positively charged atoms and molecules, we prove the existence of infinitely many Hartree-Fock critical points below the first energy threshold (that is, the lowest energy of the same system with one electron removed). This is the equivalent, in Hartree-Fock theory, of the famous Zhislin-Sigalov theorem which states the existence of infinitely many eigenvalues below the bottom of the essential spectrum of the N-particle linear Schrödinger operator. Our result improves a theorem of Lions in 1987 who already constructed infinitely many Hartree-Fock critical points, but with much higher energy. Our main contribution is the proof that the Hartree-Fock functional satisfies the Palais-Smale property below the first energy threshold. We then use minimax methods in the N-particle space, instead of working in the one-particle space.

  17. Value of information and pricing new healthcare interventions.

    PubMed

    Willan, Andrew R; Eckermann, Simon

    2012-06-01

    Previous application of value-of-information methods to optimal clinical trial design have predominantly taken a societal decision-making perspective, implicitly assuming that healthcare costs are covered through public expenditure and trial research is funded by government or donation-based philanthropic agencies. In this paper, we consider the interaction between interrelated perspectives of a societal decision maker (e.g. the National Institute for Health and Clinical Excellence [NICE] in the UK) charged with the responsibility for approving new health interventions for reimbursement and the company that holds the patent for a new intervention. We establish optimal decision making from societal and company perspectives, allowing for trade-offs between the value and cost of research and the price of the new intervention. Given the current level of evidence, there exists a maximum (threshold) price acceptable to the decision maker. Submission for approval with prices above this threshold will be refused. Given the current level of evidence and the decision maker's threshold price, there exists a minimum (threshold) price acceptable to the company. If the decision maker's threshold price exceeds the company's, then current evidence is sufficient since any price between the thresholds is acceptable to both. On the other hand, if the decision maker's threshold price is lower than the company's, then no price is acceptable to both and the company's optimal strategy is to commission additional research. The methods are illustrated using a recent example from the literature.

  18. High-wafer-yield, high-performance vertical cavity surface-emitting lasers

    NASA Astrophysics Data System (ADS)

    Li, Gabriel S.; Yuen, Wupen; Lim, Sui F.; Chang-Hasnain, Constance J.

    1996-04-01

    Vertical cavity surface emitting lasers (VCSELs) with very low threshold current and voltage of 340 (mu) A and 1.5 V is achieved. The molecular beam epitaxially grown wafers are grown with a highly accurate, low cost and versatile pre-growth calibration technique. One- hundred percent VCSEL wafer yield is obtained. Low threshold current is achieved with a native oxide confined structure with excellent current confinement. Single transverse mode with stable, predetermined polarization direction up to 18 times threshold is also achieved, due to stable index guiding provided by the structure. This is the highest value reported to data for VCSELs. We have established that p-contact annealing in these devices is crucial for low voltage operation, contrary to the general belief. Uniform doping in the mirrors also appears not to be inferior to complicated doping engineering. With these design rules, very low threshold voltage VCSELs are achieved with very simple growth and fabrication steps.

  19. Neurometric amplitude-modulation detection threshold in the guinea-pig ventral cochlear nucleus

    PubMed Central

    Sayles, Mark; Füllgrabe, Christian; Winter, Ian M

    2013-01-01

    Amplitude modulation (AM) is a pervasive feature of natural sounds. Neural detection and processing of modulation cues is behaviourally important across species. Although most ecologically relevant sounds are not fully modulated, physiological studies have usually concentrated on fully modulated (100% modulation depth) signals. Psychoacoustic experiments mainly operate at low modulation depths, around detection threshold (∼5% AM). We presented sinusoidal amplitude-modulated tones, systematically varying modulation depth between zero and 100%, at a range of modulation frequencies, to anaesthetised guinea-pigs while recording spikes from neurons in the ventral cochlear nucleus (VCN). The cochlear nucleus is the site of the first synapse in the central auditory system. At this locus significant signal processing occurs with respect to representation of AM signals. Spike trains were analysed in terms of the vector strength of spike synchrony to the amplitude envelope. Neurons showed either low-pass or band-pass temporal modulation transfer functions, with the proportion of band-pass responses increasing with increasing sound level. The proportion of units showing a band-pass response varies with unit type: sustained chopper (CS) > transient chopper (CT) > primary-like (PL). Spike synchrony increased with increasing modulation depth. At the lowest modulation depth (6%), significant spike synchrony was only observed near to the unit's best modulation frequency for all unit types tested. Modulation tuning therefore became sharper with decreasing modulation depth. AM detection threshold was calculated for each individual unit as a function of modulation frequency. Chopper units have significantly better AM detection thresholds than do primary-like units. AM detection threshold is significantly worse at 40 dB vs. 10 dB above pure-tone spike rate threshold. Mean modulation detection thresholds for sounds 10 dB above pure-tone spike rate threshold at best modulation frequency are (95% CI) 11.6% (10.0–13.1) for PL units, 9.8% (8.2–11.5) for CT units, and 10.8% (8.4–13.2) for CS units. The most sensitive guinea-pig VCN single unit AM detection thresholds are similar to human psychophysical performance (∼3% AM), while the mean neurometric thresholds approach whole animal behavioural performance (∼10% AM). PMID:23629508

  20. Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics.

    PubMed

    Hansen, Anja; Géneaux, Romain; Günther, Axel; Krüger, Alexander; Ripken, Tammo

    2013-06-01

    In femtosecond laser ophthalmic surgery tissue dissection is achieved by photodisruption based on laser induced optical breakdown. In order to minimize collateral damage to the eye laser surgery systems should be optimized towards the lowest possible energy threshold for photodisruption. However, optical aberrations of the eye and the laser system distort the irradiance distribution from an ideal profile which causes a rise in breakdown threshold energy even if great care is taken to minimize the aberrations of the system during design and alignment. In this study we used a water chamber with an achromatic focusing lens and a scattering sample as eye model and determined breakdown threshold in single pulse plasma transmission loss measurements. Due to aberrations, the precise lower limit for breakdown threshold irradiance in water is still unknown. Here we show that the threshold energy can be substantially reduced when using adaptive optics to improve the irradiance distribution by spatial beam shaping. We found that for initial aberrations with a root-mean-square wave front error of only one third of the wavelength the threshold energy can still be reduced by a factor of three if the aberrations are corrected to the diffraction limit by adaptive optics. The transmitted pulse energy is reduced by 17% at twice the threshold. Furthermore, the gas bubble motions after breakdown for pulse trains at 5 kilohertz repetition rate show a more transverse direction in the corrected case compared to the more spherical distribution without correction. Our results demonstrate how both applied and transmitted pulse energy could be reduced during ophthalmic surgery when correcting for aberrations. As a consequence, the risk of retinal damage by transmitted energy and the extent of collateral damage to the focal volume could be minimized accordingly when using adaptive optics in fs-laser surgery.

  1. Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics

    PubMed Central

    Hansen, Anja; Géneaux, Romain; Günther, Axel; Krüger, Alexander; Ripken, Tammo

    2013-01-01

    In femtosecond laser ophthalmic surgery tissue dissection is achieved by photodisruption based on laser induced optical breakdown. In order to minimize collateral damage to the eye laser surgery systems should be optimized towards the lowest possible energy threshold for photodisruption. However, optical aberrations of the eye and the laser system distort the irradiance distribution from an ideal profile which causes a rise in breakdown threshold energy even if great care is taken to minimize the aberrations of the system during design and alignment. In this study we used a water chamber with an achromatic focusing lens and a scattering sample as eye model and determined breakdown threshold in single pulse plasma transmission loss measurements. Due to aberrations, the precise lower limit for breakdown threshold irradiance in water is still unknown. Here we show that the threshold energy can be substantially reduced when using adaptive optics to improve the irradiance distribution by spatial beam shaping. We found that for initial aberrations with a root-mean-square wave front error of only one third of the wavelength the threshold energy can still be reduced by a factor of three if the aberrations are corrected to the diffraction limit by adaptive optics. The transmitted pulse energy is reduced by 17% at twice the threshold. Furthermore, the gas bubble motions after breakdown for pulse trains at 5 kilohertz repetition rate show a more transverse direction in the corrected case compared to the more spherical distribution without correction. Our results demonstrate how both applied and transmitted pulse energy could be reduced during ophthalmic surgery when correcting for aberrations. As a consequence, the risk of retinal damage by transmitted energy and the extent of collateral damage to the focal volume could be minimized accordingly when using adaptive optics in fs-laser surgery. PMID:23761849

  2. Threshold Haemoglobin Levels and the Prognosis of Stable Coronary Disease: Two New Cohorts and a Systematic Review and Meta-Analysis

    PubMed Central

    Shah, Anoop D.; Nicholas, Owen; Timmis, Adam D.; Feder, Gene; Abrams, Keith R.; Chen, Ruoling; Hingorani, Aroon D.; Hemingway, Harry

    2011-01-01

    Background Low haemoglobin concentration has been associated with adverse prognosis in patients with angina and myocardial infarction (MI), but the strength and shape of the association and the presence of any threshold has not been precisely evaluated. Methods and findings A retrospective cohort study was carried out using the UK General Practice Research Database. 20,131 people with a new diagnosis of stable angina and no previous acute coronary syndrome, and 14,171 people with first MI who survived for at least 7 days were followed up for a mean of 3.2 years. Using semi-parametric Cox regression and multiple adjustment, there was evidence of threshold haemoglobin values below which mortality increased in a graded continuous fashion. For men with MI, the threshold value was 13.5 g/dl (95% confidence interval [CI] 13.2–13.9); the 29.5% of patients with haemoglobin below this threshold had an associated hazard ratio for mortality of 2.00 (95% CI 1.76–2.29) compared to those with haemoglobin values in the lowest risk range. Women tended to have lower threshold haemoglobin values (e.g, for MI 12.8 g/dl; 95% CI 12.1–13.5) but the shape and strength of association did not differ between the genders, nor between patients with angina and MI. We did a systematic review and meta-analysis that identified ten previously published studies, reporting a total of only 1,127 endpoints, but none evaluated thresholds of risk. Conclusions There is an association between low haemoglobin concentration and increased mortality. A large proportion of patients with coronary disease have haemoglobin concentrations below the thresholds of risk defined here. Intervention trials would clarify whether increasing the haemoglobin concentration reduces mortality. Please see later in the article for the Editors' Summary PMID:21655315

  3. Unidirectional threshold switching in Ag/Si-based electrochemical metallization cells for high-density bipolar RRAM applications

    NASA Astrophysics Data System (ADS)

    Wang, Chao; Song, Bing; Li, Qingjiang; Zeng, Zhongming

    2018-03-01

    We herein present a novel unidirectional threshold selector for cross-point bipolar RRAM array. The proposed Ag/amorphous Si based threshold selector showed excellent threshold characteristics in positive field, such as high selectivity ( 105), steep slope (< 5 mV/decade) and low off-state current (< 300 pA). Meanwhile, the selector exhibited rectifying characteristics in the high resistance state as well and the rectification ratio was as high as 103 at ± 1.5 V. Nevertheless, due to the high reverse current about 9 mA at - 3 V, this unidirectional threshold selector can be used as a selection element for bipolar-type RRAM. By integrating a bipolar RRAM device with the selector, experiments showed that the undesired sneak was significantly suppressed, indicating its potentiality for high-density integrated nonvolatile memory applications.

  4. Evidence for thermally assisted threshold switching behavior in nanoscale phase-change memory cells

    NASA Astrophysics Data System (ADS)

    Le Gallo, Manuel; Athmanathan, Aravinthan; Krebs, Daniel; Sebastian, Abu

    2016-01-01

    In spite of decades of research, the details of electrical transport in phase-change materials are still debated. In particular, the so-called threshold switching phenomenon that allows the current density to increase steeply when a sufficiently high voltage is applied is still not well understood, even though there is wide consensus that threshold switching is solely of electronic origin. However, the high thermal efficiency and fast thermal dynamics associated with nanoscale phase-change memory (PCM) devices motivate us to reassess a thermally assisted threshold switching mechanism, at least in these devices. The time/temperature dependence of the threshold switching voltage and current in doped Ge2Sb2Te5 nanoscale PCM cells was measured over 6 decades in time at temperatures ranging from 40 °C to 160 °C. We observe a nearly constant threshold switching power across this wide range of operating conditions. We also measured the transient dynamics associated with threshold switching as a function of the applied voltage. By using a field- and temperature-dependent description of the electrical transport combined with a thermal feedback, quantitative agreement with experimental data of the threshold switching dynamics was obtained using realistic physical parameters.

  5. Method and system for controlling a rotational speed of a rotor of a turbogenerator

    DOEpatents

    Stahlhut, Ronnie Dean; Vuk, Carl Thomas

    2008-12-30

    A system and method controls a rotational speed of a rotor or shaft of a turbogenerator in accordance with a present voltage level on a direct current bus. A lower threshold and a higher threshold are established for a speed of a rotor or shaft of a turbogenerator. A speed sensor determines speed data or a speed signal for the rotor or shaft associated with a turbogenerator. A voltage regulator adjusts a voltage level associated with a direct current bus within a target voltage range if the speed data or speed signal indicates that the speed is above the higher threshold or below the lower threshold.

  6. Electric field characteristics of electroconvulsive therapy with individualized current amplitude: a preclinical study.

    PubMed

    Lee, Won Hee; Lisanby, Sarah H; Laine, Andrew F; Peterchev, Angel V

    2013-01-01

    This study examines the characteristics of the electric field induced in the brain by electroconvulsive therapy (ECT) with individualized current amplitude. The electric field induced by bilateral (BL), bifrontal (BF), right unilateral (RUL), and frontomedial (FM) ECT electrode configurations was computed in anatomically realistic finite element models of four nonhuman primates (NHPs). We generated maps of the electric field strength relative to an empirical neural activation threshold, and determined the stimulation strength and focality at fixed current amplitude and at individualized current amplitudes corresponding to seizure threshold (ST) measured in the anesthetized NHPs. The results show less variation in brain volume stimulated above threshold with individualized current amplitudes (16-36%) compared to fixed current amplitude (30-62%). Further, the stimulated brain volume at amplitude-titrated ST is substantially lower than that for ECT with conventional fixed current amplitudes. Thus individualizing the ECT stimulus current could compensate for individual anatomical variability and result in more focal and uniform electric field exposure across different subjects compared to the standard clinical practice of using high, fixed current for all patients.

  7. Chiral recognition of sandalwood odorants.

    PubMed

    Bajgrowicz, J A; Frater, G

    2000-01-01

    Looking for more efficient sandalwood oil smelling compounds, new campholenic aldehyde derivatives with rigidifying cyclopropane rings were prepared. For some of them, having the lowest odor threshold ever measured for this type of odorants and a very appreciated scent, close to that of the scarce natural sandalwood oils, pure stereoisomers were obtained and their olfactory properties were evaluated. Thus acquired structure-odor relationship data, together with consolidated and completed previous knowledge on structurally different sandalwood-smelling compounds, allowed to propose new models of the sandalwood olfactophore.

  8. Nanoimprinted organic semiconductor laser pumped by a light-emitting diode.

    PubMed

    Tsiminis, Georgios; Wang, Yue; Kanibolotsky, Alexander L; Inigo, Anto R; Skabara, Peter J; Samuel, Ifor D W; Turnbull, Graham A

    2013-05-28

    An organic semiconductor laser, simply fabricated by UV-nanoimprint lithography (UV-NIL), that is pumped with a pulsed InGaN LED is demonstrated. Molecular weight optimization of the polymer gain medium on a nanoimprinted polymer distributed feedback resonator enables the lowest reported UV-NIL laser threshold density of 770 W cm(-2) , establishing the potential for scalable organic laser fabrication compatible with mass-produced LEDs. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Commissioning and first tests of the MAGIC telescope

    NASA Astrophysics Data System (ADS)

    Baixeras, C.; Bastieri, D.; Bigongiari, C.; Blanch, O.; Blanchot, G.; Bock, R.; Bretz, T.; Chilingarian, A.; Coarasa, J. A.; Colombo, E.; Contreras, J. C.; Corti, D.; Cortina, J.; Domingo, C.; Domingo, E.; Ferenc, D.; Fernández, E.; Flix, J.; Fonseca, V.; Font, L.; Galante, N.; Gaug, M.; Garczarczyk, M.; Gebauer, J.; Giller, M.; Goebel, F.; Hengstebeck, T.; Jacone, P.; de Jager, O. C.; Kalekin, O.; Kestel, M.; Kneiske, T.; Laille, A.; López, M.; López, J.; Lorenz, E.; Mannheim, K.; Mariotti, M.; Martínez, M.; Mase, K.; Merck, M.; Meucci, M.; Miralles, L.; Mirzoyan, R.; Moralejo, A.; Wilhelmi, E. Oña; Orduña, R.; Paneque, D.; Paoletti, R.; Pascoli, D.; Pavel, N.; Pegna, R.; Peruzzo, L.; Piccioli, A.; Roberts, A.; Reyes, R.; Saggion, A.; Sánchez, A.; Sartori, P.; Scalzotto, V.; Schweizer, T.; Sillanpaa, A.; Sobczynska, D.; Stamerra, A.; Stepanian, A.; Stiehler, R.; Takalo, L.; Teshima, M.; Tonello, N.; Torres, A.; Turini, N.; Vitale, V.; Volkov, S.; Wagner, R. M.; Wibig, T.; Wittek, W.

    2004-02-01

    Major Atmospheric Gamma Imaging Cherenkov telescope is starting its operations with a set of engineering runs to tune the telescope subsystem elements to be ready for the first physics campaign. Many technical improvements have been developed and implemented in several elements of the telescope to reach the lowest energy threshold ever obtained by an Imaging Atmospheric Cherenkov Telescope. A general description of the telescope is presented. The commissioning of the telescope's elements is described and the expected performances are reviewed with the final detector set-up.

  10. Pixel structures to compensate nonuniform threshold voltage and mobility of polycrystalline silicon thin-film transistors using subthreshold current for large-size active matrix organic light-emitting diode displays

    NASA Astrophysics Data System (ADS)

    Na, Jun-Seok; Kwon, Oh-Kyong

    2014-01-01

    We propose pixel structures for large-size and high-resolution active matrix organic light-emitting diode (AMOLED) displays using a polycrystalline silicon (poly-Si) thin-film transistor (TFT) backplane. The proposed pixel structures compensate the variations of the threshold voltage and mobility of the driving TFT using the subthreshold current. The simulated results show that the emission current error of the proposed pixel structure B ranges from -2.25 to 2.02 least significant bit (LSB) when the variations of the threshold voltage and mobility of the driving TFT are ±0.5 V and ±10%, respectively.

  11. On the threshold conditions for electron beam damage of asbestos amosite fibers in the transmission electron microscope (TEM).

    PubMed

    Martin, Joannie; Beauparlant, Martin; Sauvé, Sébastien; L'Espérance, Gilles

    2016-12-01

    Asbestos amosite fibers were investigated to evaluate the damage caused by a transmission electron microscope (TEM) electron beam. Since elemental x-ray intensity ratios obtained by energy dispersive x-ray spectroscopy (EDS) are commonly used for asbestos identification, the impact of beam damage on these ratios was evaluated. It was determined that the magnesium/silicon ratio best represented the damage caused to the fiber. Various tests showed that most fibers have a current density threshold above which the chemical composition of the fiber is modified. The value of this threshold current density varied depending on the fiber, regardless of fiber diameter, and in some cases could not be determined. The existence of a threshold electron dose was also demonstrated. This value was dependent on the current density used and can be increased by providing a recovery period between exposures to the electron beam. This study also established that the electron beam current is directly related to the damage rate above a current density of 165 A/cm 2 . The large number of different results obtained suggest, that in order to ensure that the amosite fibers are not damaged, analysis should be conducted below a current density of 100 A/cm 2 .

  12. Onset of carbon-carbon bonding in the Nb(5)C(y) (y = 0-6) clusters: a threshold photo-ionisation and density functional theory study.

    PubMed

    Dryza, Viktoras; Gascooke, Jason R; Buntine, Mark A; Metha, Gregory F

    2009-02-21

    We have used photo-ionisation efficiency spectroscopy to determine the ionisation potentials (IPs) of the niobium-carbide clusters, Nb(5)C(y) (y = 0-6). Of these clusters Nb(5)C(2) and Nb(5)C(3) exhibit the lowest IPs. Complementary density functional theory calculations have been performed to locate the lowest energy isomers for each cluster. By comparing the experimental IPs with those calculated for candidate isomers, the structures of the Nb(5)C(y) clusters observed in the experiment are inferred. For all these structures, the underlying Nb(5) cluster has either a "prolate" or "oblate" trigonal bipyramid geometry. Both Nb(5)C(5) and Nb(5)C(6) are shown to contain carbon-carbon bonding in the form of one and two molecular C(2) units, respectively.

  13. Ground and excited state dissociation dynamics of ionized 1,1-difluoroethene.

    PubMed

    Gridelet, E; Dehareng, D; Locht, R; Lorquet, A J; Lorquet, J C; Leyh, B

    2005-09-22

    The kinetic energy release distributions (KERDs) for the fluorine atom loss from the 1,1-difluoroethene cation have been recorded with two spectrometers in two different energy ranges. A first experiment uses dissociative photoionization with the He(I) and Ne(I) resonance lines, providing the ions with a broad internal energy range, up to 7 eV above the dissociation threshold. The second experiment samples the metastable range, and the average ion internal energy is limited to about 0.2 eV above the threshold. In both energy domains, KERDs are found to be bimodal. Each component has been analyzed by the maximum entropy method. The narrow, low kinetic energy components display for both experiments the characteristics of a statistical, simple bond cleavage reaction: constraint equal to the square root of the fragment kinetic energy and ergodicity index higher than 90%. Furthermore, this component is satisfactorily accounted for in the metastable time scale by the orbiting transition state theory. Potential energy surfaces corresponding to the five lowest electronic states of the dissociating 1,1-C2H2F2+ ion have been investigated by ab initio calculations at various levels. The equilibrium geometry of these states, their dissociation energies, and their vibrational wavenumbers have been calculated, and a few conical intersections between these surfaces have been identified. It comes out that the ionic ground state X2B1 is adiabatically correlated with the lowest dissociation asymptote. Its potential energy curve increases in a monotonic way along the reaction coordinate, giving rise to the narrow KERD component. Two states embedded in the third photoelectron band (B2A1 at 15.95 eV and C2B2 at 16.17 eV) also correlate with the lowest asymptote at 14.24 eV. We suggest that their repulsive behavior along the reaction coordinate be responsible for the KERD high kinetic energy contribution.

  14. Automatic delineation of functional lung volumes with 68Ga-ventilation/perfusion PET/CT.

    PubMed

    Le Roux, Pierre-Yves; Siva, Shankar; Callahan, Jason; Claudic, Yannis; Bourhis, David; Steinfort, Daniel P; Hicks, Rodney J; Hofman, Michael S

    2017-10-10

    Functional volumes computed from 68 Ga-ventilation/perfusion (V/Q) PET/CT, which we have shown to correlate with pulmonary function test parameters (PFTs), have potential diagnostic utility in a variety of clinical applications, including radiotherapy planning. An automatic segmentation method would facilitate delineation of such volumes. The aim of this study was to develop an automated threshold-based approach to delineate functional volumes that best correlates with manual delineation. Thirty lung cancer patients undergoing both V/Q PET/CT and PFTs were analyzed. Images were acquired following inhalation of Galligas and, subsequently, intravenous administration of 68 Ga-macroaggreted-albumin (MAA). Using visually defined manual contours as the reference standard, various cutoff values, expressed as a percentage of the maximal pixel value, were applied. The average volume difference and Dice similarity coefficient (DSC) were calculated, measuring the similarity of the automatic segmentation and the reference standard. Pearson's correlation was also calculated to compare automated volumes with manual volumes, and automated volumes optimized to PFT indices. For ventilation volumes, mean volume difference was lowest (- 0.4%) using a 15%max threshold with Pearson's coefficient of 0.71. Applying this cutoff, median DSC was 0.93 (0.87-0.95). Nevertheless, limits of agreement in volume differences were large (- 31.0 and 30.2%) with differences ranging from - 40.4 to + 33.0%. For perfusion volumes, mean volume difference was lowest and Pearson's coefficient was highest using a 15%max threshold (3.3% and 0.81, respectively). Applying this cutoff, median DSC was 0.93 (0.88-0.93). Nevertheless, limits of agreement were again large (- 21.1 and 27.8%) with volume differences ranging from - 18.6 to + 35.5%. Using the 15%max threshold, moderate correlation was demonstrated with FEV1/FVC (r = 0.48 and r = 0.46 for ventilation and perfusion images, respectively). No correlation was found between other PFT indices. To automatically delineate functional volumes with 68 Ga-V/Q PET/CT, the most appropriate cutoff was 15%max for both ventilation and perfusion images. However, using this unique threshold systematically provided unacceptable variability compared to the reference volume and relatively poor correlation with PFT parameters. Accordingly, a visually adapted semi-automatic method is favored, enabling rapid and quantitative delineation of lung functional volumes with 68 Ga-V/Q PET/CT.

  15. Neural Correlates and Mechanisms of Spatial Release From Masking: Single-Unit and Population Responses in the Inferior Colliculus

    PubMed Central

    Lane, Courtney C.; Delgutte, Bertrand

    2007-01-01

    Spatial release from masking (SRM), a factor in listening in noisy environments, is the improvement in auditory signal detection obtained when a signal is separated in space from a masker. To study the neural mechanisms of SRM, we recorded from single units in the inferior colliculus (IC) of barbiturate-anesthetized cats, focusing on low-frequency neurons sensitive to interaural time differences. The stimulus was a broadband chirp train with a 40-Hz repetition rate in continuous broadband noise, and the unit responses were measured for several signal and masker (virtual) locations. Masked thresholds (the lowest signal-to-noise ratio, SNR, for which the signal could be detected for 75% of the stimulus presentations) changed systematically with signal and masker location. Single-unit thresholds did not necessarily improve with signal and masker separation; instead, they tended to reflect the units’ azimuth preference. Both how the signal was detected (through a rate increase or decrease) and how the noise masked the signal response (suppressive or excitatory masking) changed with signal and masker azimuth, consistent with a cross-correlator model of binaural processing. However, additional processing, perhaps related to the signal’s amplitude modulation rate, appeared to influence the units’ responses. The population masked thresholds (the most sensitive unit’s threshold at each signal and masker location) did improve with signal and masker separation as a result of the variety of azimuth preferences in our unit sample. The population thresholds were similar to human behavioral thresholds in both SNR value and shape, indicating that these units may provide a neural substrate for low-frequency SRM. PMID:15857966

  16. A high-throughput method to measure NaCl and acid taste thresholds in mice.

    PubMed

    Ishiwatari, Yutaka; Bachmanov, Alexander A

    2009-05-01

    To develop a technique suitable for measuring NaCl taste thresholds in genetic studies, we conducted a series of experiments with outbred CD-1 mice using conditioned taste aversion (CTA) and two-bottle preference tests. In Experiment 1, we compared conditioning procedures involving either oral self-administration of LiCl or pairing NaCl intake with LiCl injections and found that thresholds were the lowest after LiCl self-administration. In Experiment 2, we compared different procedures (30-min and 48-h tests) for testing conditioned mice and found that the 48-h test is more sensitive. In Experiment 3, we examined the effects of varying strength of conditioned (NaCl or LiCl taste intensity) and unconditioned (LiCl toxicity) stimuli and concluded that 75-150 mM LiCl or its mixtures with NaCl are the optimal stimuli for conditioning by oral self-administration. In Experiment 4, we examined whether this technique is applicable for measuring taste thresholds for other taste stimuli. Results of these experiments show that conditioning by oral self-administration of LiCl solutions or its mixtures with other taste stimuli followed by 48-h two-bottle tests of concentration series of a conditioned stimulus is an efficient and sensitive method to measure taste thresholds. Thresholds measured with this technique were 2 mM for NaCl and 1 mM for citric acid. This approach is suitable for simultaneous testing of large numbers of animals, which is required for genetic studies. These data demonstrate that mice, like several other species, generalize CTA from LiCl to NaCl, suggesting that they perceive taste of NaCl and LiCl as qualitatively similar, and they also can generalize CTA of a binary mixture of taste stimuli to mixture components.

  17. Ascending-ramp biphasic waveform has a lower defibrillation threshold and releases less troponin I than a truncated exponential biphasic waveform.

    PubMed

    Huang, Jian; Walcott, Gregory P; Ruse, Richard B; Bohanan, Scott J; Killingsworth, Cheryl R; Ideker, Raymond E

    2012-09-11

    We tested the hypothesis that the shape of the shock waveform affects not only the defibrillation threshold but also the amount of cardiac damage. Defibrillation thresholds were determined for 11 waveforms-3 ascending-ramp waveforms, 3 descending-ramp waveforms, 3 rectilinear first-phase biphasic waveforms, a Gurvich waveform, and a truncated exponential biphasic waveform-in 6 pigs with electrodes in the right ventricular apex and superior vena cava. The ascending, descending, and rectilinear waveforms had 4-, 8-, and 16-millisecond first phases and a 3.5-millisecond rectilinear second phase that was half the voltage of the first phase. The exponential biphasic waveform had a 60% first-phase and a 50% second-phase tilt. In a second study, we attempted to defibrillate after 10 seconds of ventricular fibrillation with a single ≈30-J shock (6 pigs successfully defibrillated with 8-millisecond ascending, 8-millisecond rectilinear, and truncated exponential biphasic waveforms). Troponin I blood levels were determined before and 2 to 10 hours after the shock. The lowest-energy defibrillation threshold was for the 8-milliseconds ascending ramp (14.6±7.3 J [mean±SD]), which was significantly less than for the truncated exponential (19.6±6.3 J). Six hours after shock, troponin I was significantly less for the ascending-ramp waveform (0.80±0.54 ng/mL) than for the truncated exponential (1.92±0.47 ng/mL) or the rectilinear waveform (1.17±0.45 ng/mL). The ascending ramp has a significantly lower defibrillation threshold and at ≈30 J causes 58% less troponin I release than the truncated exponential biphasic shock. Therefore, the shock waveform affects both the defibrillation threshold and the amount of cardiac damage.

  18. Modelling the line-of-sight contribution in substructure lensing

    NASA Astrophysics Data System (ADS)

    Despali, Giulia; Vegetti, Simona; White, Simon D. M.; Giocoli, Carlo; van den Bosch, Frank C.

    2018-04-01

    We investigate how Einstein rings and magnified arcs are affected by small-mass dark-matter haloes placed along the line of sight to gravitational lens systems. By comparing the gravitational signature of line-of-sight haloes with that of substructures within the lensing galaxy, we derive a mass-redshift relation that allows us to rescale the detection threshold (i.e. lowest detectable mass) for substructures to a detection threshold for line-of-sight haloes at any redshift. We then quantify the line-of-sight contribution to the total number density of low-mass objects that can be detected through strong gravitational lensing. Finally, we assess the degeneracy between substructures and line-of-sight haloes of different mass and redshift to provide a statistical interpretation of current and future detections, with the aim of distinguishing between cold dark matter and warm dark matter. We find that line-of-sight haloes statistically dominate with respect to substructures, by an amount that strongly depends on the source and lens redshifts, and on the chosen dark-matter model. Substructures represent about 30 percent of the total number of perturbers for low lens and source redshifts (as for the SLACS lenses), but less than 10 per cent for high-redshift systems. We also find that for data with high enough signal-to-noise ratio and angular resolution, the non-linear effects arising from a double-lens-plane configuration are such that one is able to observationally recover the line-of-sight halo redshift with an absolute error precision of 0.15 at the 68 per cent confidence level.

  19. Health hazards related to conidia of Cladosporium-biological air pollutants in Poland, central Europe.

    PubMed

    Weryszko-Chmielewska, Elzbieta; Kasprzyk, Idalia; Nowak, Malgorzata; Sulborska, Aneta; Kaczmarek, Joanna; Szymanska, Agata; Haratym, Weronika; Gilski, Miroslaw; Jedryczka, Malgorzata

    2018-03-01

    The spores of Cladosporium Link. are often present in the air in high quantities and produce many allergenic proteins, which may lead to asthma. An aerobiological spore monitoring program can inform patients about the current spore concentration in air and help their physicians determine the spore dose that is harmful for a given individual. This makes it possible to develop optimized responses and propose personalized therapy for a particular sensitive patient. The aim of this study was to assess the extent of the human health hazard posed by the fungal genus Cladosporium. For the first time, we have determined the number of days on which air samples in Poland exceeded the concentrations linked to allergic responses of sensitive patients, according to thresholds established by three different groups (2800/3000/4000 spores per 1m 3 of the air). The survey was conducted over three consecutive growing seasons (April-September, 2010-2012) in three cities located in different climate zones of Poland (Poznan, Lublin and Rzeszow). The average number of days exceeding 2800 spores per cubic meter (the lowest threshold) ranged from 61 (2010) through 76 (2011) to 93 (2012), though there was significant variation between cities. In each year the highest concentration of spores in the air was detected in either Poznan or Lublin, both located on large plains with intensive agriculture. We have proposed that an effective, science-based software platform to support policy-making on air quality should incorporate biological air pollutant data, such as allergenic fungal spores and pollen grains. Copyright © 2017. Published by Elsevier B.V.

  20. Responses of caddisfly larvae (Brachycentrus spp. ) to temperature, food availability and current velocity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gallepp, G.W.

    1977-07-01

    Larvae of the stream caddisflies, Brachycentrus americanus and Brachycentrus occidentalis, were studied in eight simulated stream channels to determine their behavioral responses to temperature, food availability (brine shrimp) and current velocity. For both species, filtering, withdrawn and case-building were the primary behavior patterns of larvae that had attached their cases to the substrate. Most larvae not attached to the substrate were crawling or holding. As temperatures increased above 8 C, B. occidentalis larvae filtered more frequantly; but above 20 C the percentage of larvae filtering steadily decreased and the percentage withdrawn increased dramatically with increasing temperature. Percentages of larvae case-buildingmore » and unattached generally decreased over the range of 4 to 27 C. Despite this decrease in case-building, B. occidentalis larvae generally grew faster as temperature increased from 4 to 16 C. Behavior of B. americanus as a function of temperature was similar to behavior of B. occidentalis. Both species responded to decreased ration by increasing the percentage of time filtering. Although many larvae were unattached and probably grazing in Lawrence Creek, few larvae were unattached in the laboratory, even at the lowest ration (1.2 percent of the body weight per day). Growth and case-building activity of B. americanus larvae were directly related to ration. Over the range of current velocities of 7 to 26 cm/sec, behavior of B. occidentalis changed little. At 5 cm/sec fewer larvae filtered and more were unattached; this suggested a threshold response to current velocity. Increasing temperatures from 10 to 20 C caused the percentage withdrawn at low velocities to increase; however, this trend was hardly noticeable at velocities above 10 cm/sec. In these tests, Brachycentrus were more responsive to temperature and food availability than to current velocity.« less

  1. Defining indoor heat thresholds for health in the UK.

    PubMed

    Anderson, Mindy; Carmichael, Catriona; Murray, Virginia; Dengel, Andy; Swainson, Michael

    2013-05-01

    It has been recognised that as outdoor ambient temperatures increase past a particular threshold, so do mortality/morbidity rates. However, similar thresholds for indoor temperatures have not yet been identified. Due to a warming climate, the non-sustainability of air conditioning as a solution, and the desire for more energy-efficient airtight homes, thresholds for indoor temperature should be defined as a public health issue. The aim of this paper is to outline the need for indoor heat thresholds and to establish if they can be identified. Our objectives include: describing how indoor temperature is measured; highlighting threshold measurements and indices; describing adaptation to heat; summary of the risk of susceptible groups to heat; reviewing the current evidence on the link between sleep, heat and health; exploring current heat and health warning systems and thresholds; exploring the built environment and the risk of overheating; and identifying the gaps in current knowledge and research. A global literature search of key databases was conducted using a pre-defined set of keywords to retrieve peer-reviewed and grey literature. The paper will apply the findings to the context of the UK. A summary of 96 articles, reports, government documents and textbooks were analysed and a gap analysis was conducted. Evidence on the effects of indoor heat on health implies that buildings are modifiers of the effect of climate on health outcomes. Personal exposure and place-based heat studies showed the most significant correlations between indoor heat and health outcomes. However, the data are sparse and inconclusive in terms of identifying evidence-based definitions for thresholds. Further research needs to be conducted in order to provide an evidence base for threshold determination. Indoor and outdoor heat are related but are different in terms of language and measurement. Future collaboration between the health and building sectors is needed to develop a common language and an index for indoor heat and health thresholds in a changing climate.

  2. The influence of current direction on phosphene thresholds evoked by transcranial magnetic stimulation.

    PubMed

    Kammer, T; Beck, S; Erb, M; Grodd, W

    2001-11-01

    To quantify phosphene thresholds evoked by transcranial magnetic stimulation (TMS) in the occipital cortex as a function of induced current direction. Phosphene thresholds were determined in 6 subjects. We compared two stimulator types (Medtronic-Dantec and Magstim) with monophasic pulses using the standard figure-of-eight coils and systematically varied hemisphere (left and right) and induced current direction (latero-medial and medio-lateral). Each measurement was made 3 times, with a new stimulation site chosen for each repetition. Only those stimulation sites were investigated where phosphenes were restricted to one visual hemifield. Coil positions were stereotactically registered. Functional magnetic resonance imaging (fMRI) of retinotopic areas was performed in 5 subjects to individually characterize the borders of visual areas; TMS stimulation sites were coregistered with respect to visual areas. Despite large interindividual variance we found a consistent pattern of phosphene thresholds. They were significantly lower if the direction of the induced current was oriented from lateral to medial in the occipital lobe rather than vice versa. No difference with respect to the hemisphere was found. Threshold values normalized to the square root of the stored energy in the stimulators were lower with the Medtronic-Dantec device than with the Magstim device. fMRI revealed that stimulation sites generating unilateral phosphenes were situated at V2 and V3. Variability of phosphene thresholds was low within a cortical patch of 2x2cm(2). Stimulation over V1 yields phosphenes in both visual fields. The excitability of visual cortical areas depends on the direction of the induced current with a preference for latero-medial currents. Although the coil positions used in this study were centered over visual areas V2 and V3, we cannot rule out the possibility that subcortical structures or V1 could actually be the main generator for phosphenes.

  3. Ellipticity of near-threshold harmonics from stretched molecules.

    PubMed

    Li, Weiyan; Dong, Fulong; Yu, Shujuan; Wang, Shang; Yang, Shiping; Chen, Yanjun

    2015-11-30

    We study the ellipticity of near-threshold harmonics (NTH) from aligned molecules with large internuclear distances numerically and analytically. The calculated harmonic spectra show a broad plateau for NTH which is several orders of magnitude higher than that for high-order harmonics. In particular, the NTH plateau shows high ellipticity at small and intermediate orientation angles. Our analyses reveal that the main contributions to the NTH plateau come from the transition of the electron from continuum states to these two lowest bound states of the system, which are strongly coupled together by the laser field. Besides continuum states, higher excited states also play a role in the NTH plateau, resulting in a large phase difference between parallel and perpendicular harmonics and accordingly high ellipticity of the NTH plateau. The NTH plateau with high intensity and large ellipticity provides a promising manner for generating strong elliptically-polarized extreme-ultraviolet (EUV) pulses.

  4. Best dispersal strategies in spatially heterogeneous environments: optimization of the principal eigenvalue for indefinite fractional Neumann problems.

    PubMed

    Pellacci, Benedetta; Verzini, Gianmaria

    2018-05-01

    We study the positive principal eigenvalue of a weighted problem associated with the Neumann spectral fractional Laplacian. This analysis is related to the investigation of the survival threshold in population dynamics. Our main result concerns the optimization of such threshold with respect to the fractional order [Formula: see text], the case [Formula: see text] corresponding to the standard Neumann Laplacian: when the habitat is not too fragmented, the principal positive eigenvalue can not have local minima for [Formula: see text]. As a consequence, the best strategy for survival is either following the diffusion with [Formula: see text] (i.e. Brownian diffusion), or with the lowest possible s (i.e. diffusion allowing long jumps), depending on the size of the domain. In addition, we show that analogous results hold for the standard fractional Laplacian in [Formula: see text], in periodic environments.

  5. Selective weighting of cutaneous receptor feedback and associated balance impairments following short duration space flight.

    PubMed

    Strzalkowski, Nicholas D J; Lowrey, Catherine R; Perry, Stephen D; Williams, David R; Wood, Scott J; Bent, Leah R

    2015-04-10

    The present study investigated the perception of low frequency (3 Hz) vibration on the foot sole and its relationship to standing balance following short duration space flight in nine astronauts. Both 3 Hz vibration perception threshold (VPT) and standing balance measures increased on landing day compared to pre-flight. Contrary to our hypothesis, a positive linear relationship between these measures was not observed; however astronauts with the most sensitive skin (lowest 3 Hz VPT) were found to have the largest sway on landing day. While the change in foot sole sensitivity does not appear to directly relate to standing balance control, an exploratory strategy may be employed by astronauts whose threshold to pressure information is lower. Understanding sensory adaptations and balance control has implications to improve balance control strategies following space flight and in sensory impaired populations on earth. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Polarization operator of a photon in a magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katkov, V. M., E-mail: V.M.Katkov@inp.nsk.su

    2016-08-15

    The polarization operator of a photon in a static uniform magnetic field has been studied at photon energies both above and below the threshold of electron–positron pair production by a photon. In the first order of the fine-structure constant α, expressions for the refractive index of a photon with a certain polarization in both low and high fields as compared to the critical field H{sub 0} = 4.41 × 10{sup 13} G have been obtained. Both the purely quantum range of photon energies, where the particles of a pair are produced at the lowest Landau levels, and the region ofmore » applicability of the semiclassical approximation in the case of the population of high energy levels have been considered. A general spectral integral formula has been obtained with divergent threshold terms separated in an explicit form.« less

  7. Reduced quenching effects of organic gain media with metallic electrodes via introducing a conjugated macroelectrolyte interlayer

    NASA Astrophysics Data System (ADS)

    Yi, Jianpeng; Huang, Jinjin; Liu, Chengfang; Lai, Wen-Yong; Huang, Wei

    2017-01-01

    We have demonstrated amplified spontaneous emission (ASE) restoration and threshold reduction by introducing a novel water/alcohol soluble conjugated macroelectrolyte, tris(4-(7-(9,9-di(hexyl-1-N,N-diethanolamino)-9H-fluoren-2-yl)-9,9-di(hexyl-1-N,N-diethanolamino)-9H-fluoren-2-yl)phenyl)amine (TPAOH), serving as an interfacial layer between the gain media layer, dioctyl substituted polyfluorene (PFO), and the Ag electrode layer. By optimizing the film thickness of TPAOH, enhanced ASE performance has been achieved with the lowest threshold of 21 μJ/cm2, demonstrating 3.5-fold reduction from 74 μJ/cm2. Atomic force microscopy results showed good compatibility between the TPAOH film and the PFO layer. The results suggest a facile and low-cost solution-processing interfacial technique to construct efficient organic semiconductor lasers in the presence of metallic electrodes.

  8. Color Differences Between Pink Veneering Ceramics and the Human Gingiva.

    PubMed

    Valente, Nicola Alberto; Sailer, Irena; Fehmer, Vincent; Thoma, Daniel Stefan

    2018-06-12

    The aim of this study was to examine 10 different shades of pink ceramic to determine which one best matches the mean color of human gingiva. Bar-shaped zirconia samples were fabricated and veneered with 1 of 10 pink zirconia veneering ceramics. The color of the gingiva at the central maxillary incisors of 20 healthy volunteers was compared to the pink veneering ceramics using a spectrophotometer (Spectroshade, MHT). The obtained color parameters L*, a*, and b* (CIELAB) of the gingiva and the ceramics were used to calculate the color difference (ΔE). Mean ΔE values were descriptively analyzed and compared to the threshold value for visibility of color differences of gingiva (ΔE = 3.1). The lowest pink ceramic ΔE value obtained (closest to the mean ΔE of all the volunteers' gingiva) was 6.2. All the tested ceramics exhibited a color difference above the threshold value for visibility.

  9. Laser Pulse Duration Is Critical For the Generation of Plasmonic Nanobubbles

    PubMed Central

    2015-01-01

    Plasmonic nanobubbles (PNBs) are transient vapor nanobubbles generated in liquid around laser-overheated plasmonic nanoparticles. Unlike plasmonic nanoparticles, PNBs’ properties are still largely unknown due to their highly nonstationary nature. Here we show the influence of the duration of the optical excitation on the energy efficacy and threshold of PNB generation. The combination of picosecond pulsed excitation with the nanoparticle clustering provides the highest energy efficacy and the lowest threshold fluence, around 5 mJ cm–2, of PNB generation. In contrast, long excitation pulses reduce the energy efficacy of PNB generation by several orders of magnitude. Ultimately, the continuous excitation has the minimal energy efficacy, nine orders of magnitude lower than that for the picosecond excitation. Thus, the duration of the optical excitation of plasmonic nanoparticles can have a stronger effect on the PNB generation than the excitation wavelength, nanoparticle size, shape, or other “stationary” properties of plasmonic nanoparticles. PMID:24916057

  10. Evidence for thermally assisted threshold switching behavior in nanoscale phase-change memory cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Gallo, Manuel; Athmanathan, Aravinthan; Krebs, Daniel

    2016-01-14

    In spite of decades of research, the details of electrical transport in phase-change materials are still debated. In particular, the so-called threshold switching phenomenon that allows the current density to increase steeply when a sufficiently high voltage is applied is still not well understood, even though there is wide consensus that threshold switching is solely of electronic origin. However, the high thermal efficiency and fast thermal dynamics associated with nanoscale phase-change memory (PCM) devices motivate us to reassess a thermally assisted threshold switching mechanism, at least in these devices. The time/temperature dependence of the threshold switching voltage and current inmore » doped Ge{sub 2}Sb{sub 2}Te{sub 5} nanoscale PCM cells was measured over 6 decades in time at temperatures ranging from 40 °C to 160 °C. We observe a nearly constant threshold switching power across this wide range of operating conditions. We also measured the transient dynamics associated with threshold switching as a function of the applied voltage. By using a field- and temperature-dependent description of the electrical transport combined with a thermal feedback, quantitative agreement with experimental data of the threshold switching dynamics was obtained using realistic physical parameters.« less

  11. Excitable Neurons, Firing Threshold Manifolds and Canards

    PubMed Central

    2013-01-01

    We investigate firing threshold manifolds in a mathematical model of an excitable neuron. The model analyzed investigates the phenomenon of post-inhibitory rebound spiking due to propofol anesthesia and is adapted from McCarthy et al. (SIAM J. Appl. Dyn. Syst. 11(4):1674–1697, [2012]). Propofol modulates the decay time-scale of an inhibitory GABAa synaptic current. Interestingly, this system gives rise to rebound spiking within a specific range of propofol doses. Using techniques from geometric singular perturbation theory, we identify geometric structures, known as canards of folded saddle-type, which form the firing threshold manifolds. We find that the position and orientation of the canard separatrix is propofol dependent. Thus, the speeds of relevant slow synaptic processes are encoded within this geometric structure. We show that this behavior cannot be understood using a static, inhibitory current step protocol, which can provide a single threshold for rebound spiking but cannot explain the observed cessation of spiking for higher propofol doses. We then compare the analyses of dynamic and static synaptic inhibition, showing how the firing threshold manifolds of each relate, and why a current step approach is unable to fully capture the behavior of this model. PMID:23945278

  12. Redefining the Speed Limit of Phase Change Memory Revealed by Time-resolved Steep Threshold-Switching Dynamics of AgInSbTe Devices

    NASA Astrophysics Data System (ADS)

    Shukla, Krishna Dayal; Saxena, Nishant; Durai, Suresh; Manivannan, Anbarasu

    2016-11-01

    Although phase-change memory (PCM) offers promising features for a ‘universal memory’ owing to high-speed and non-volatility, achieving fast electrical switching remains a key challenge. In this work, a correlation between the rate of applied voltage and the dynamics of threshold-switching is investigated at picosecond-timescale. A distinct characteristic feature of enabling a rapid threshold-switching at a critical voltage known as the threshold voltage as validated by an instantaneous response of steep current rise from an amorphous off to on state is achieved within 250 picoseconds and this is followed by a slower current rise leading to crystallization. Also, we demonstrate that the extraordinary nature of threshold-switching dynamics in AgInSbTe cells is independent to the rate of applied voltage unlike other chalcogenide-based phase change materials exhibiting the voltage dependent transient switching characteristics. Furthermore, numerical solutions of time-dependent conduction process validate the experimental results, which reveal the electronic nature of threshold-switching. These findings of steep threshold-switching of ‘sub-50 ps delay time’, opens up a new way for achieving high-speed non-volatile memory for mainstream computing.

  13. Chemical sensing thresholds for mine detection dogs

    NASA Astrophysics Data System (ADS)

    Phelan, James M.; Barnett, James L.

    2002-08-01

    Mine detection dogs have been found to be an effective method to locate buried landmines. The capabilities of the canine olfaction method are from a complex combination of training and inherent capacity of the dog for odor detection. The purpose of this effort was to explore the detection thresholds of a limited group of dogs that were trained specifically for landmine detection. Soils were contaminated with TNT and 2,4-DNT to develop chemical vapor standards to present to the dogs. Soils contained ultra trace levels of TNT and DNT, which produce extremely low vapor levels. Three groups of dogs were presented the headspace vapors from the contaminated soils in work environments for each dog group. One positive sample was placed among several that contained clean soils and, the location and vapor source (strength, type) was frequently changed. The detection thresholds for the dogs were determined from measured and extrapolated dilution of soil chemical residues and, estimated soil vapor values using phase partitioning relationships. The results showed significant variances in dog sensing thresholds, where some dogs could sense the lowest levels and others had trouble with even the highest source. The remarkable ultra-trace levels detectable by the dogs are consistent with the ultra-trace chemical residues derived from buried landmines; however, poor performance may go unnoticed without periodic challenge tests at levels consistent with performance requirements.

  14. Is the diagnostic threshold for bulimia nervosa clinically meaningful?

    PubMed

    Chapa, Danielle A N; Bohrer, Brittany K; Forbush, Kelsie T

    2018-01-01

    The DSM-5 differentiates full- and sub-threshold bulimia nervosa (BN) according to average weekly frequencies of binge eating and inappropriate compensatory behaviors. This study was the first to evaluate the modified frequency criterion for BN published in the DSM-5. The purpose of this study was to test whether community-recruited adults (N=125; 83.2% women) with current full-threshold (n=77) or sub-threshold BN (n=48) differed in comorbid psychopathology and eating disorder (ED) illness duration, symptom severity, and clinical impairment. Participants completed the Clinical Impairment Assessment and participated in semi-structured clinical interviews of ED- and non-ED psychopathology. Differences between the sub- and full-threshold BN groups were assessed using MANOVA and Chi-square analyses. ED illness duration, age-of-onset, body mass index (BMI), alcohol and drug misuse, and the presence of current and lifetime mood or anxiety disorders did not differ between participants with sub- and full-threshold BN. Participants with full-threshold BN had higher levels of clinical impairment and weight concern than those with sub-threshold BN. However, minimal clinically important difference analyses suggested that statistically significant differences between participants with sub- and full-threshold BN on clinical impairment and weight concern were not clinically significant. In conclusion, sub-threshold BN did not differ from full-threshold BN in clinically meaningful ways. Future studies are needed to identify an improved frequency criterion for BN that better distinguishes individuals in ways that will more validly inform prognosis and effective treatment planning for BN. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. The warning-sign hierarchy between quantitative subcortical motor mapping and continuous motor evoked potential monitoring during resection of supratentorial brain tumors.

    PubMed

    Seidel, Kathleen; Beck, Jürgen; Stieglitz, Lennart; Schucht, Philippe; Raabe, Andreas

    2013-02-01

    Mapping and monitoring are believed to provide an early warning sign to determine when to stop tumor removal to avoid mechanical damage to the corticospinal tract (CST). The objective of this study was to systematically compare subcortical monopolar stimulation thresholds (1-20 mA) with direct cortical stimulation (DCS)-motor evoked potential (MEP) monitoring signal abnormalities and to correlate both with new postoperative motor deficits. The authors sought to define a mapping threshold and DCS-MEP monitoring signal changes indicating a minimal safe distance from the CST. A consecutive cohort of 100 patients underwent tumor surgery adjacent to the CST while simultaneous subcortical motor mapping and DCS-MEP monitoring was used. Evaluation was done regarding the lowest subcortical mapping threshold (monopolar stimulation, train of 5 stimuli, interstimulus interval 4.0 msec, pulse duration 500 μsec) and signal changes in DCS-MEPs (same parameters, 4 contact strip electrode). Motor function was assessed 1 day after surgery, at discharge, and at 3 months postoperatively. The lowest individual motor thresholds (MTs) were as follows (MT in mA, number of patients): > 20 mA, n = 12; 11-20 mA, n = 13; 6-10 mA, n = 20; 4-5 mA, n = 30; and 1-3 mA, n = 25. Direct cortical stimulation showed stable signals in 70 patients, unspecific changes in 18, irreversible alterations in 8, and irreversible loss in 4 patients. At 3 months, 5 patients had a postoperative new or worsened motor deficit (lowest mapping MT 20 mA, 13 mA, 6 mA, 3 mA, and 1 mA). In all 5 patients DCS-MEP monitoring alterations were documented (2 sudden irreversible threshold increases and 3 sudden irreversible MEP losses). Of these 5 patients, 2 had vascular ischemic lesions (MT 20 mA, 13 mA) and 3 had mechanical CST damage (MT 1 mA, 3 mA, and 6 mA; in the latter 2 cases the resection continued after mapping and severe DCS-MEP alterations occurred thereafter). In 80% of patients with a mapping MT of 1-3 mA and in 75% of patients with a mapping MT of 1 mA, DCS-MEPs were stable or showed unspecific reversible changes, and none had a permanent motor worsening at 3 months. In contrast, 25% of patients with irreversible DCS-MEP changes and 75% of patients with irreversible DCS-MEP loss had permanent motor deficits. Mapping should primarily guide tumor resection adjacent to the CST. DCS-MEP is a useful predictor of deficits, but its value as a warning sign is limited because signal alterations were reversible in only approximately 60% of the present cases and irreversibility is a post hoc definition. The true safe mapping MT is lower than previously thought. The authors postulate a mapping MT of 1 mA or less where irreversible DCS-MEP changes and motor deficits regularly occur. Therefore, they recommend stopping tumor resection at an MT of 2 mA at the latest. The limited spatial and temporal coverage of contemporary mapping may increase error and may contribute to false, higher MTs.

  16. Breaking the current density threshold in spin-orbit-torque magnetic random access memory

    NASA Astrophysics Data System (ADS)

    Zhang, Yin; Yuan, H. Y.; Wang, X. S.; Wang, X. R.

    2018-04-01

    Spin-orbit-torque magnetic random access memory (SOT-MRAM) is a promising technology for the next generation of data storage devices. The main bottleneck of this technology is the high reversal current density threshold. This outstanding problem is now solved by a new strategy in which the magnitude of the driven current density is fixed while the current direction varies with time. The theoretical limit of minimal reversal current density is only a fraction (the Gilbert damping coefficient) of the threshold current density of the conventional strategy. The Euler-Lagrange equation for the fastest magnetization reversal path and the optimal current pulse is derived for an arbitrary magnetic cell and arbitrary spin-orbit torque. The theoretical limit of minimal reversal current density and current density for a GHz switching rate of the new reversal strategy for CoFeB/Ta SOT-MRAMs are, respectively, of the order of 105 A/cm 2 and 106 A/cm 2 far below 107 A/cm 2 and 108 A/cm 2 in the conventional strategy. Furthermore, no external magnetic field is needed for a deterministic reversal in the new strategy.

  17. Probability of an Abnormal Screening PSA Result Based on Age, Race, and PSA Threshold

    PubMed Central

    Espaldon, Roxanne; Kirby, Katharine A.; Fung, Kathy Z.; Hoffman, Richard M.; Powell, Adam A.; Freedland, Stephen J.; Walter, Louise C.

    2014-01-01

    Objective To determine the distribution of screening PSA values in older men and how different PSA thresholds affect the proportion of white, black, and Latino men who would have an abnormal screening result across advancing age groups. Methods We used linked national VA and Medicare data to determine the value of the first screening PSA test (ng/mL) of 327,284 men age 65+ who underwent PSA screening in the VA healthcare system in 2003. We calculated the proportion of men with an abnormal PSA result based on age, race, and common PSA thresholds. Results Among men age 65+, 8.4% had a PSA >4.0ng/mL. The percentage of men with a PSA >4.0ng/mL increased with age and was highest in black men (13.8%) versus white (8.0%) or Latino men (10.0%) (P<0.001). Combining age and race, the probability of having a PSA >4.0ng/mL ranged from 5.1% of Latino men age 65–69 to 27.4% of black men age 85+. Raising the PSA threshold from >4.0ng/mL to >10.0ng/mL, reclassified the greatest percentage of black men age 85+ (18.3% absolute change) and the lowest percentage of Latino men age 65–69 (4.8% absolute change) as being under the biopsy threshold (P<0.001). Conclusions Age, race, and PSA threshold together affect the pre-test probability of an abnormal screening PSA result. Based on screening PSA distributions, stopping screening among men whose PSA < 3ng/ml means over 80% of white and Latino men age 70+ would stop further screening, and increasing the biopsy threshold to >10ng/ml has the greatest effect on reducing the number of older black men who will face biopsy decisions after screening. PMID:24439009

  18. Bedding material affects mechanical thresholds, heat thresholds and texture preference

    PubMed Central

    Moehring, Francie; O’Hara, Crystal L.; Stucky, Cheryl L.

    2015-01-01

    It has long been known that the bedding type animals are housed on can affect breeding behavior and cage environment. Yet little is known about its effects on evoked behavior responses or non-reflexive behaviors. C57BL/6 mice were housed for two weeks on one of five bedding types: Aspen Sani Chips® (standard bedding for our institute), ALPHA-Dri®, Cellu-Dri™, Pure-o’Cel™ or TEK-Fresh. Mice housed on Aspen exhibited the lowest (most sensitive) mechanical thresholds while those on TEK-Fresh exhibited 3-fold higher thresholds. While bedding type had no effect on responses to punctate or dynamic light touch stimuli, TEK-Fresh housed animals exhibited greater responsiveness in a noxious needle assay, than those housed on the other bedding types. Heat sensitivity was also affected by bedding as animals housed on Aspen exhibited the shortest (most sensitive) latencies to withdrawal whereas those housed on TEK-Fresh had the longest (least sensitive) latencies to response. Slight differences between bedding types were also seen in a moderate cold temperature preference assay. A modified tactile conditioned place preference chamber assay revealed that animals preferred TEK-Fresh to Aspen bedding. Bedding type had no effect in a non-reflexive wheel running assay. In both acute (two day) and chronic (5 week) inflammation induced by injection of Complete Freund’s Adjuvant in the hindpaw, mechanical thresholds were reduced in all groups regardless of bedding type, but TEK-Fresh and Pure-o’Cel™ groups exhibited a greater dynamic range between controls and inflamed cohorts than Aspen housed mice. PMID:26456764

  19. Aging deteriorated perception of urge-to-cough without changing cough reflex threshold to citric acid in female never-smokers.

    PubMed

    Ebihara, Satoru; Ebihara, Takae; Kanezaki, Masashi; Gui, Peijun; Yamasaki, Miyako; Arai, Hiroyuki; Kohzuki, Masahiro

    2011-06-28

    The effect of aging on the cognitive aspect of cough has not been studied yet. The purpose of this study is to investigate the aging effect on the perception of urge-to-cough in healthy individuals. Fourteen young, female, healthy never-smokers were recruited via public postings. Twelve elderly female healthy never-smokers were recruited from a nursing home residence. The cough reflex threshold and the urge-to-cough were evaluated by inhalation of citric acid. The cough reflex sensitivities were defined as the lowest concentration of citric acid that elicited two or more coughs (C2) and five or more coughs (C5). The urge-to-cough was evaluated using a modified the Borg scale. There was no significant difference in the cough reflex threshold to citric acid between young and elderly subjects. The urge-to-cough scores at the concentration of C2 and C5 were significantly smaller in the elderly than young subjects. The urge-to-cough log-log slope in elderly subjects (0.73 ± 0.71 point · L/g) was significantly gentler than those of young subjects (1.35 ± 0.53 point · L/g, p < 0.01). There were no significant differences in the urge-to-cough threshold estimated between young and elderly subjects. The cough reflex threshold did not differ between young and elderly subjects whereas cognition of urge-to-cough was significantly decreased in elderly subjects in female never-smokers. Objective monitoring of cough might be important in the elderly people.

  20. Soft x-ray free-electron laser induced damage to inorganic scintillators

    DOE PAGES

    Burian, Tomáš; Hájková, Věra; Chalupský, Jaromír; ...

    2015-01-07

    An irreversible response of inorganic scintillators to intense soft x-ray laser radiation was investigated at the FLASH (Free-electron LASer in Hamburg) facility. Three ionic crystals, namely, Ce:YAG (cerium-doped yttrium aluminum garnet), PbWO4 (lead tungstate), and ZnO (zinc oxide), were exposed to single 4.6 nm ultra-short laser pulses of variable pulse energy (up to 12 μJ) under normal incidence conditions with tight focus. Damaged areas produced with various levels of pulse fluences, were analyzed on the surface of irradiated samples using differential interference contrast (DIC) and atomic force microscopy (AFM). The effective beam area of 22.2 ± 2.2 μm2 was determinedmore » by means of the ablation imprints method with the use of poly(methyl methacrylate) - PMMA. Applied to the three inorganic materials, this procedure gave almost the same values of an effective area. The single-shot damage threshold fluence was determined for each of these inorganic materials. The Ce:YAG sample seems to be the most radiation resistant under the given irradiation conditions, its damage threshold was determined to be as high as 660.8 ± 71.2 mJ/cm2. Contrary to that, the PbWO4 sample exhibited the lowest radiation resistance with a threshold fluence of 62.6 ± 11.9 mJ/cm2. The threshold for ZnO was found to be 167.8 ± 30.8 mJ/cm2. Both interaction and material characteristics responsible for the damage threshold difference are discussed in the article.« less

  1. Signal processing system for electrotherapy applications

    NASA Astrophysics Data System (ADS)

    Płaza, Mirosław; Szcześniak, Zbigniew

    2017-08-01

    The system of signal processing for electrotherapeutic applications is proposed in the paper. The system makes it possible to model the curve of threshold human sensitivity to current (Dalziel's curve) in full medium frequency range (1kHz-100kHz). The tests based on the proposed solution were conducted and their results were compared with those obtained according to the assumptions of High Tone Power Therapy method and referred to optimum values. Proposed system has high dynamics and precision of mapping the curve of threshold human sensitivity to current and can be used in all methods where threshold curves are modelled.

  2. Effects of modulation phase on profile analysis in normal-hearing and hearing-impaired listeners

    NASA Astrophysics Data System (ADS)

    Rogers, Deanna; Lentz, Jennifer

    2003-04-01

    The ability to discriminate between sounds with different spectral shapes in the presence of amplitude modulation was measured in normal-hearing and hearing-impaired listeners. The standard stimulus was the sum of equal-amplitude modulated tones, and the signal stimulus was generated by increasing the level of half the tones (up components) and decreasing the level of half the tones (down components). The down components had the same modulation phase, and a phase shift was applied to the up components to encourage segregation from the down tones. The same phase shift was used in both standard and signal stimuli. Profile-analysis thresholds were measured as a function of the phase shift between up and down components. The phase shifts were 0, 30, 45, 60, 90, and 180 deg. As expected, thresholds were lowest when all tones had the same modulation phase and increased somewhat with increasing phase disparity. This small increase in thresholds was similar for both groups. These results suggest that hearing-impaired listeners are able to use modulation phase to group sounds in a manner similar to that of normal listeners. [Work supported by NIH (DC 05835).

  3. Super low threshold plasmonic WGM lasing from an individual ZnO hexagonal microrod on an Au substrate for plasmon lasers.

    PubMed

    Dong, H M; Yang, Y H; Yang, G W

    2015-03-05

    We demonstrate an individual ZnO hexagonal microrod on the surface of an Au substrate which can become new sources for manufacturing miniature ZnO plasmon lasers by surface plasmon polariton coupling to whispering-gallery modes (WGMs). We also demonstrate that the rough surface of Au substrates can acquire a more satisfied enhancement of ZnO emission if the surface geometry of Au substrates is appropriate. Furthermore, we achieve high Q factor and super low threshold plasmonic WGM lasing from an individual ZnO hexagonal microrod on the surface of the Au substrate, in which Q factor can reach 5790 and threshold is 0.45 KW/cm(2) which is the lowest value reported to date for ZnO nanostructures lasing, at least 10 times smaller than that of ZnO at the nanometer. Electron transfer mechanisms are proposed to understand the physical origin of quenching and enhancement of ZnO emission on the surface of Au substrates. These investigations show that this novel coupling mode holds a great potential of ZnO hexagonal micro- and nanorods for data storage, bio-sensing, optical communications as well as all-optic integrated circuits.

  4. [Patterns of action potential firing in cortical neurons of neonatal mice and their electrophysiological property].

    PubMed

    Furong, Liu; Shengtian, L I

    2016-05-25

    To investigate patterns of action potential firing in cortical heurons of neonatal mice and their electrophysiological properties. The passive and active membrane properties of cortical neurons from 3-d neonatal mice were observed by whole-cell patch clamp with different voltage and current mode. Three patterns of action potential firing were identified in response to depolarized current injection. The effects of action potential firing patterns on voltage-dependent inward and outward current were found. Neurons with three different firing patterns had different thresholds of depolarized current. In the morphology analysis of action potential, the three type neurons were different in rise time, duration, amplitude and threshold of the first action potential evoked by 80 pA current injection. The passive properties were similar in three patterns of action potential firing. These results indicate that newborn cortical neurons exhibit different patterns of action potential firing with different action potential parameters such as shape and threshold.

  5. GALVANOTAXIS OF SLIME MOLD

    PubMed Central

    Anderson, John D.

    1951-01-01

    The plasmodium of Physarum polycephalum reacts to direct current by migration toward the cathode. Cathodal migration was obtained upon a variety of substrata such as baked clay, paper, cellophane, and agar with a current density in the substratum of 1.0 µa./mm.2 Injury was produced by current densities of 8.0 to 12.0 µa./mm.2 The negative galvanotactic response was not due to electrode products. Attempts to demonstrate that the response was due to gradients or orientation in the substratum, pH changes in the mold, cataphoresis, electroosmosis, or endosmosis were not successful. The addition of salts (CaCl2, LiCl, NaCl, Na2SO4, NaHCO3, KCl, MgSO4, sodium citrate, and sea water) to agar indicated that change of cations had more effect than anions upon galvanotaxis and that the effect was upon threshold values. K ion (0.01 M KCl) increased the lower threshold value to 8.0 µa./mm.2 and the upper threshold value to 32.0 µa./mm.2, whereas the Li ion (0.01 M LiCl) increased the lower threshold to only 4.0 µa./mm.2 and the upper threshold to only 16.0 µa./mm.2 The passage of electric current produced no increase in the rate of cathodal migration; neither was there a decrease until injurious current densities were reached. With increase of subthreshold current densities there was a progressive decrease in rate of migration toward the anode until complete anodal inhibition occurred. There was orientation at right angles to the electrodes in alternating current (60 cycle) with current density of 4.0 µa./mm.2 and in direct current of 5.0 µa./mm.2 when polarity of current was reversed every minute. It is concluded that the negative galvanotactic response of P. polycephalum is due to inhibition of migration on the anodal side of the plasmodium and that this inhibition results in the limitation of the normal migration of the mold to a cathodal direction. The mechanism of the anodal inhibition has not been elucidated. PMID:14873916

  6. FInvestigation of enhancement mode HfO2 insulated N-polarity GaN/InN/GaN/In0.9Al0.1N heterostructure MISHEMT for high-frequency applications

    NASA Astrophysics Data System (ADS)

    Mohanbabu, A.; Mohankumar, N.; Godwin Raj, D.; Sarkar, Partha

    2017-08-01

    In this paper, we examined normally-OFF N-polar InN-channel Metal insulated semiconductor high-electron mobility transistors (MISHEMTs) device with a relaxed In0.9Al0.1N buffer layer. In addition, the enhancement-mode operation of the N-polar structure was investigated. The effect of scaling in N-polar MISHEMT, such as the dielectric and the channel thickness, alter the electrical behavior of the device. We have achieved a maximum drain current of 1.17 A/mm, threshold voltage (VT) =0.728 V, transconductance (gm) of 2.9 S mm-1, high ION/IOFF current ratio of 3.23×103, lowest ON-state resistance (RON) of 0.41 Ω mm and an intrinsic delay time (τ) of 1.456 Fs along with high-frequency performance with ft/ fmaxof 90 GHz/109 GHz and 180 GHz/260 GHz for TCH =0.5 nm at Vds =0.5 V and 1.0 V. The numerically simulated results of highly confined GaN/InN/GaN/In0.9Al0.1N heterostructure MISHEMT exhibits outstanding potential as one of the possibility to replace presently used N-polar MISHEMTs for delivering high power density and frequency at RF/power amplifier applications.

  7. Successional stage of biological soil crusts: an accurate indicator of ecohydrological condition

    USGS Publications Warehouse

    Belnap, Jayne; Wilcox, Bradford P.; Van Scoyoc, Matthew V.; Phillips, Susan L.

    2013-01-01

    Biological soil crusts are a key component of many dryland ecosystems. Following disturbance, biological soil crusts will recover in stages. Recently, a simple classification of these stages has been developed, largely on the basis of external features of the crusts, which reflects their level of development (LOD). The classification system has six LOD classes, from low (1) to high (6). To determine whether the LOD of a crust is related to its ecohydrological function, we used rainfall simulation to evaluate differences in infiltration, runoff, and erosion among crusts in the various LODs, across a range of soil depths and with different wetting pre-treatments. We found large differences between the lowest and highest LODs, with runoff and erosion being greatest from the lowest LOD. Under dry antecedent conditions, about 50% of the water applied ran off the lowest LOD plots, whereas less than 10% ran off the plots of the two highest LODs. Similarly, sediment loss was 400 g m-2 from the lowest LOD and almost zero from the higher LODs. We scaled up the results from these simulations using the Rangeland Hydrology and Erosion Model. Modelling results indicate that erosion increases dramatically as slope length and gradient increase, especially beyond the threshold values of 10 m for slope length and 10% for slope gradient. Our findings confirm that the LOD classification is a quick, easy, nondestructive, and accurate index of hydrological condition and should be incorporated in field and modelling assessments of ecosystem health.

  8. Unified planar process for fabricating heterojunction bipolar transistors and buried-heterostructure lasers utilizing impurity-induced disordering

    NASA Astrophysics Data System (ADS)

    Thornton, R. L.; Mosby, W. J.; Chung, H. F.

    1988-12-01

    We describe results on a novel geometry of heterojunction bipolar transistor that has been realized by impurity-induced disordering. This structure is fabricated by a method that is compatible with techniques for the fabrication of low threshold current buried-heterostructure lasers. We have demonstrated this compatibility by fabricating a hybrid laser/transistor structure that operates as a laser with a threshold current of 6 mA at room temperature, and as a transistor with a current gain of 5.

  9. High-temperature performance of MoS2 thin-film transistors: Direct current and pulse current-voltage characteristics

    NASA Astrophysics Data System (ADS)

    Jiang, C.; Rumyantsev, S. L.; Samnakay, R.; Shur, M. S.; Balandin, A. A.

    2015-02-01

    We report on fabrication of MoS2 thin-film transistors (TFTs) and experimental investigations of their high-temperature current-voltage characteristics. The measurements show that MoS2 devices remain functional to temperatures of at least as high as 500 K. The temperature increase results in decreased threshold voltage and mobility. The comparison of the direct current (DC) and pulse measurements shows that the direct current sub-linear and super-linear output characteristics of MoS2 thin-films devices result from the Joule heating and the interplay of the threshold voltage and mobility temperature dependences. At temperatures above 450 K, a kink in the drain current occurs at zero gate voltage irrespective of the threshold voltage value. This intriguing phenomenon, referred to as a "memory step," was attributed to the slow relaxation processes in thin films similar to those in graphene and electron glasses. The fabricated MoS2 thin-film transistors demonstrated stable operation after two months of aging. The obtained results suggest new applications for MoS2 thin-film transistors in extreme-temperature electronics and sensors.

  10. Effect of Polymer Gate Dielectrics on Charge Transport in Carbon Nanotube Network Transistors: Low-k Insulator for Favorable Active Interface.

    PubMed

    Lee, Seung-Hoon; Xu, Yong; Khim, Dongyoon; Park, Won-Tae; Kim, Dong-Yu; Noh, Yong-Young

    2016-11-30

    Charge transport in carbon nanotube network transistors strongly depends on the properties of the gate dielectric that is in direct contact with the semiconducting carbon nanotubes. In this work, we investigate the dielectric effects on charge transport in polymer-sorted semiconducting single-walled carbon nanotube field-effect transistors (s-SWNT-FETs) by using three different polymer insulators: A low-permittivity (ε r ) fluoropolymer (CYTOP, ε r = 1.8), poly(methyl methacrylate) (PMMA, ε r = 3.3), and a high-ε r ferroelectric relaxor [P(VDF-TrFE-CTFE), ε r = 14.2]. The s-SWNT-FETs with polymer dielectrics show typical ambipolar charge transport with high ON/OFF ratios (up to ∼10 5 ) and mobilities (hole mobility up to 6.77 cm 2 V -1 s -1 for CYTOP). The s-SWNT-FET with the lowest-k dielectric, CYTOP, exhibits the highest mobility owing to formation of a favorable interface for charge transport, which is confirmed by the lowest activation energies, evaluated by the fluctuation-induced tunneling model (FIT) and the traditional Arrhenius model (E aFIT = 60.2 meV and E aArr = 10 meV). The operational stability of the devices showed a good agreement with the activation energies trend (drain current decay ∼14%, threshold voltage shift ∼0.26 V in p-type regime of CYTOP devices). The poor performance in high-ε r devices is accounted for by a large energetic disorder caused by the randomly oriented dipoles in high-k dielectrics. In conclusion, the low-k dielectric forms a favorable interface with s-SWNTs for efficient charge transport in s-SWNT-FETs.

  11. Auditory-nerve single-neuron thresholds to electrical stimulation from scala tympani electrodes.

    PubMed

    Parkins, C W; Colombo, J

    1987-12-31

    Single auditory-nerve neuron thresholds were studied in sensory-deafened squirrel monkeys to determine the effects of electrical stimulus shape and frequency on single-neuron thresholds. Frequency was separated into its components, pulse width and pulse rate, which were analyzed separately. Square and sinusoidal pulse shapes were compared. There were no or questionably significant threshold differences in charge per phase between sinusoidal and square pulses of the same pulse width. There was a small (less than 0.5 dB) but significant threshold advantage for 200 microseconds/phase pulses delivered at low pulse rates (156 pps) compared to higher pulse rates (625 pps and 2500 pps). Pulse width was demonstrated to be the prime determinant of single-neuron threshold, resulting in strength-duration curves similar to other mammalian myelinated neurons, but with longer chronaxies. The most efficient electrical stimulus pulse width to use for cochlear implant stimulation was determined to be 100 microseconds/phase. This pulse width delivers the lowest charge/phase at threshold. The single-neuron strength-duration curves were compared to strength-duration curves of a computer model based on the specific anatomy of auditory-nerve neurons. The membrane capacitance and resulting chronaxie of the model can be varied by altering the length of the unmyelinated termination of the neuron, representing the unmyelinated portion of the neuron between the habenula perforata and the hair cell. This unmyelinated segment of the auditory-nerve neuron may be subject to aminoglycoside damage. Simulating a 10 micron unmyelinated termination for this model neuron produces a strength-duration curve that closely fits the single-neuron data obtained from aminoglycoside deafened animals. Both the model and the single-neuron strength-duration curves differ significantly from behavioral threshold data obtained from monkeys and humans with cochlear implants. This discrepancy can best be explained by the involvement of higher level neurologic processes in the behavioral responses. These findings suggest that the basic principles of neural membrane function must be considered in developing or analyzing electrical stimulation strategies for cochlear prostheses if the appropriate stimulation of frequency specific populations of auditory-nerve neurons is the objective.

  12. Anatomy of filamentary threshold switching in amorphous niobium oxide.

    PubMed

    Li, Shuai; Liu, Xinjun; Nandi, Sanjoy Kumar; Elliman, Robert Glen

    2018-06-25

    The threshold switching behaviour of Pt/NbOx/TiN devices is investigated as a function device area and NbOx film thickness and shown to reveal important insight into the structure of the self-assembled switching region. The devices exhibit combined selector-memory (1S1R) behavior after an initial voltage-controlled forming process, but exhibit symmetric threshold switching when the RESET and SET currents are kept below a critical value. In this mode, the threshold and hold voltages are independent of the device area and film thickness but the threshold current (power), while independent of device area, decreases with increasing film thickness. These results are shown to be consistent with a structure in which the threshold switching volume is confined, both laterally and vertically, to the region between the residual memory filament and the TiN electrode, and where the memory filament has a core-shell structure comprising a metallic core and a semiconducting shell. The veracity of this structure is demonstrated by comparing experimental results with the predictions of a simple circuit model, and more detailed finite element simulations. These results provide further insight into the structure and operation of NbOx threshold switching devices that have application in emerging memory and neuromorphic computing fields. © 2018 IOP Publishing Ltd.

  13. Effect of Unmodulated 5-kHz Alternating Currents Versus Transcutaneous Electrical Nerve Stimulation on Mechanical and Thermal Pain, Tactile Threshold, and Peripheral Nerve Conduction: A Double-Blind, Placebo-Controlled Crossover Trial.

    PubMed

    Avendaño-Coy, Juan; Gómez-Soriano, Julio; Goicoechea-García, Carlos; Basco-López, Julian Angel; Taylor, Julian

    2017-05-01

    To investigate the effect of unmodulated 5-kHz alternating current on mechanical pain threshold (MPT), heat pain threshold (HPT), tactile threshold (TT), and peripheral nerve conduction (PNC) compared with transcutaneous electrical nerve stimulation (TENS) and sham stimulation. National referral center. Randomized, double-blind, placebo-controlled crossover trial. Healthy volunteers (N=38). No dropouts or adverse events were reported. TENS, unmodulated 5-kHz currents, and sham stimulation were applied on the radial nerve for 20 minutes with a 24-hour washout period between them and concealed intervention allocation. Four measures were taken: before, during, and 2 after the interventions. Algometry was used to assess MPT, a Peltier thermode for HPT using the method of limits, Von Frey filaments for TT, and radial nerve compound action potential. No differences were observed on MPT, HPT, and PNC when 5-kHz current and TENS were compared. However, TT increased 56.2mN (95% confidence interval [CI], 28.8-83.6) in the TENS group compared with the 5-kHz current group during intervention. Compared with sham stimulation during intervention, MPT increased 4.7N (95% CI, 0.3-9.2) using 5-kHz current and 10.4N (95% CI, 3.5-17.3) with TENS. TT increased 17.2mN (95% CI, 4.7-29.7) with 5-kHz current and 73.4mN (95% CI, 47.5-99.2) with TENS. However, HPT increased 1.0°C (95% CI, 0.2-2.0) only with TENS. For the PNC, no differences were found among the 3 groups. Unmodulated 5-kHz current produced an increase in somatosensory thresholds that was greater than placebo but not when compared with TENS; however, participants perceived 5-kHz currents to be more comfortable and showed more habituation to them. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  14. Parametric changes in response equilibrium during an intra-cranial self stimulation (ICSS) task: can reward value be assessed independently of absolute threshold?

    PubMed

    Easterling, K W; Holtzman, S G

    1997-01-01

    Traditional ICSS methodologies have attempted to evaluate changes in the rewarding value of brain stimulation by assessing the lowest value of the stimulation that will support responding. However, orderly changes in suprathreshold indicants of hedonic magnitude such as titration point have been shown. In the present experiments, rats were trained to respond on two ICSS autotitration schedules in which every response on one lever produced stimulation of the medial forebrain bundle, and every Xth response decreased either the stimulation current or the stimulation frequency. At any time, a response on a second "reset" lever restored the stimulation current or frequency available on the stimulation lever to its starting level and operationally defined changes in "reward value". In order to study this titration point measure, two response requirements (responses/stepdown; step size) and two stimulation parameters (initial stimulation level; train duration) were systematically varied. Under both current and frequency titration schedules, data indicated that response rate and titration point remained stable over repeated trials and multiple testing days--parameters being constant. Across all conditions, compared to the frequency titration schedule, subjects responding under the current titration schedule showed significantly higher titration points and lower rates of responding. Indicating the independence of rate and titration point data, parametric manipulations did not affect titration point and rate data concurrently. Results support the conclusion that titration point is a relative measure of "reward value" that is generally independent of response rate, but that is affected by manipulations that alter the amount of stimulation available between "resets". Additional work is needed in order to determine the relationship between the magnitude of stimulation needed to maintain minimal responding and that needed to maintain response equilibrium in an autotitration task.

  15. Randomness fault detection system

    NASA Technical Reports Server (NTRS)

    Russell, B. Don (Inventor); Aucoin, B. Michael (Inventor); Benner, Carl L. (Inventor)

    1996-01-01

    A method and apparatus are provided for detecting a fault on a power line carrying a line parameter such as a load current. The apparatus monitors and analyzes the load current to obtain an energy value. The energy value is compared to a threshold value stored in a buffer. If the energy value is greater than the threshold value a counter is incremented. If the energy value is greater than a high value threshold or less than a low value threshold then a second counter is incremented. If the difference between two subsequent energy values is greater than a constant then a third counter is incremented. A fault signal is issued if the counter is greater than a counter limit value and either the second counter is greater than a second limit value or the third counter is greater than a third limit value.

  16. Quantitative Sensory Testing and Current Perception Threshold Testing in Patients With Chronic Pain Following Lower Extremity Fracture.

    PubMed

    Griffioen, Mari A; Greenspan, Joel D; Johantgen, Meg; Von Rueden, Kathryn; O'Toole, Robert V; Dorsey, Susan G; Renn, Cynthia L

    2018-01-01

    Chronic pain is a significant problem for patients with lower extremity injuries. While pain hypersensitivity has been identified in many chronic pain conditions, it is not known whether patients with chronic pain following lower extremity fracture report pain hypersensitivity in the injured leg. To quantify and compare peripheral somatosensory function and sensory nerve activation thresholds in persons with chronic pain following lower extremity fractures with a cohort of persons with no history of lower extremity fractures. This was a cross-sectional study where quantitative sensory testing and current perception threshold testing were conducted on the injured and noninjured legs of cases and both legs of controls. A total of 14 cases and 28 controls participated in the study. Mean time since injury at the time of testing for cases was 22.3 (standard deviation = 12.1) months. The warmth detection threshold ( p = .024) and nerve activation thresholds at 2,000 Hz ( p < .001) and 250 Hz ( p = .002), respectively, were significantly higher in cases compared to controls. This study suggests that patients with chronic pain following lower extremity fractures may experience hypoesthesia in the injured leg, which contrasts with the finding of hyperesthesia previously observed in other chronic pain conditions but is in accord with patients with nerve injuries and surgeries. This is the first study to examine peripheral sensory nerve function at the site of injury in patients with chronic pain following lower extremity fractures using quantitative sensory testing and current perception threshold testing.

  17. Potentiated antibodies to mu-opiate receptors: effect on integrative activity of the brain.

    PubMed

    Geiko, V V; Vorob'eva, T M; Berchenko, O G; Epstein, O I

    2003-01-01

    The effect of homeopathically potentiated antibodies to mu-receptors (10(-100) wt %) on integrative activity of rat brain was studied using the models of self-stimulation of the lateral hypothalamus and convulsions produced by electric current. Electric current was delivered through electrodes implanted into the ventromedial hypothalamus. Single treatment with potentiated antibodies to mu-receptors increased the rate of self-stimulation and decreased the threshold of convulsive seizures. Administration of these antibodies for 7 days led to further activation of the positive reinforcement system and decrease in seizure thresholds. Distilled water did not change the rate of self-stimulation and seizure threshold.

  18. Analysis of the threshold switching mechanism of a Te-SbO selector device for crosspoint nonvolatile memory applications

    NASA Astrophysics Data System (ADS)

    Kim, Young Seok; Park, Ji Woon; Lee, Jong Ho; Choi, In Ah; Heo, Jaeyeong; Kim, Hyeong Joon

    2017-10-01

    The threshold switching mechanism of Te-SbO thin films with a unique microstructure in which a Te nanocluster is present in the SbO matrix is analyzed. During the electro-forming process, amorphous Te filaments are formed in the Te nanocluster. However, unlike conventional Ovonic threshold switching (TS) selector devices, it has been demonstrated that the off-current flows along the filament. Numerical calculations show that the off-current is due to the trap present in the filament. We also observed changes in TS parameters through controls in the strength or volume of the filaments.

  19. Should we expect population thresholds for wildlife disease?

    USGS Publications Warehouse

    Lloyd-Smith, James O.; Cross, P.C.; Briggs, C.J.; Daugherty, M.; Getz, W.M.; Latto, J.; Sanchez, M.; Smith, A.; Swei, A.

    2005-01-01

    Host population thresholds for invasion or persistence of infectious disease are core concepts of disease ecology, and underlie on-going and controversial disease control policies based on culling and vaccination. Empirical evidence for these thresholds in wildlife populations has been sparse, however, though recent studies have narrowed this gap. Here we review the theoretical bases for population thresholds for disease, revealing why they are difficult to measure and sometimes are not even expected, and identifying important facets of wildlife ecology left out of current theories. We discuss strengths and weaknesses of selected empirical studies that have reported disease thresholds for wildlife, identify recurring obstacles, and discuss implications of our imperfect understanding of wildlife thresholds for disease control policy.

  20. Inhibitory effect of aniracetam on N-type calcium current in acutely isolated rat neuronal cells.

    PubMed

    Koike, H; Saito, H; Matsuki, N

    1993-04-01

    Effects of aniracetam on whole-cell calcium currents were studied in acutely isolated neuronal cells from postnatal rat ventromedial hypothalamus. There were three types of inward calcium currents, one low-threshold transient current and two high-threshold sustained currents. The nicardipine sensitive L-type current was activated at -20 mV or more depolarized potentials, and the omega-conotoxin sensitive N-type current was recorded at more positive potentials than the L-type. Aniracetam inhibited the N-type current in a dose-dependent manner without affecting the other two types of calcium currents. The effect appeared soon after the addition and lasted for several minutes during washing. Since the N-type current is thought to regulate the release of transmitters, the inhibitory effect may contribute to the nootropic property of aniracetam by modifying the neurotransmission.

  1. Influence of Electrical and Ionic Conductivities of Organic Electronic Ion Pump on Acetylcholine Exchange Performance

    PubMed Central

    Abdullayeva, Nazrin; Sankir, Mehmet

    2017-01-01

    By using an easy and effective method of depositing conjugated polymers (PEDOT:PSS) on flexible substrates, a new design for organic bioelectronic devices has been developed. The purpose was to build up a system that mimics the motion of neurotransmitters in the synaptic cleft by obtaining an electrical to chemical signal transport. Fourier transform infrared (FTIR) spectroscopy and Raman measurements have demonstrated that electrochemical overoxidation region which separates the pristine PEDOT:PSS electrodes and allows ionic conduction has been achieved successfully. The influence of both electrical and ionic conductivities on organic electronic ion pump (OEIP) performances has been studied. The ultimate goal was to achieve the highest equilibrium current density at the lowest applied voltage via enhancing the electrical conductivity of PEDOT:PSS and ionic conductivity of electrochemically overoxidized region. The highest equilibrium current density, which corresponds to 4.81 × 1017 number of ions of acetylcholine was about 41 μA cm−2 observed for the OEIP with the electrical conductivities of 54 S cm−1. This was a threshold electrical conductivity beyond which the OEIP performances were not changed much. Once Nafion™ has been applied for enhancing the ionic conductivity, the equilibrium current density increased about ten times and reached up to 408 μA cm−2. Therefore, it has been demonstrated that the OEIP performance mainly scales with the ionic conductivity. A straightforward method of producing organic bioelectronics is proposed here may provide a clue for their effortless mass production in the near future. PMID:28772946

  2. Low Threshold Voltage Continuous Wave Vertical-Cavity Surface-Emitting Lasers

    DTIC Science & Technology

    1993-04-26

    Data are presented demonstrating a design and fabrication process for the realization of low- threshold , high-output vertical-cavity surface-emitting...layers), the low series resistance of the design results in a bias voltage on o 1.8 V at a threshold current of 1.9 mA for 10-micrometer-diam devices.... Vertical-cavity surface-emitting lasers.

  3. Oxide-apertured VCSEL with short period superlattice

    NASA Astrophysics Data System (ADS)

    Li, Lin; Zhong, Jingchang; Zhang, Yongming; Su, Wei; Zhao, Yingjie; Yan, Changling; Hao, Yongqin; Jiang, Xiaoguang

    2004-12-01

    Novel distributed Bragg reflectors (DBRs) with 4.5 pairs of GaAs/AlAs short period superlattice (SPS) used in oxide-apertured vertical-cavity surface-emitting lasers (VCSELs) were designed. The structure of a 22-period Al_(0.9)Ga_(0.1)As (69.5 nm)/4.5-pair [GaAs (10 nm)-AlAs (1.9 nm)] DBR was grown on an n+ GaAs substrate (100) 2 deg. off toward <111>A by molecular beam epitaxy. The emitting wavelength was 850 nm with low threshold current of about 2 mA, corresponding to the threshold current density of 2 kA/cm2. The maximum output power was more than 1 mW. The VCSEL device temperature was increased by heating ambient temperature from 20 to 100 (Celsius degree) and the threshold current increased slowly with the increase of temperature.

  4. Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost-utility study.

    PubMed

    Bagust, A; Grayson, A D; Palmer, N D; Perry, R A; Walley, T

    2006-01-01

    To assess the cost effectiveness of drug eluting stents (DES) compared with conventional stents for treatment of symptomatic coronary artery disease in the UK. Cost-utility analysis of audit based patient subgroups by means of a simple economic model. Tertiary care. 12 month audit data for 2884 patients receiving percutaneous coronary intervention with stenting at the Cardiothoracic Centre Liverpool between January 2000 and December 2002. Risk of repeat revascularisation within 12 months of index procedure and reduction in risk from use of DES. Economic modelling was used to estimate the cost-utility ratio and threshold price premium. Four factors were identified for patients undergoing elective surgery (n = 1951) and two for non-elective surgery (n = 933) to predict risk of repeat revascularisation within 12 months. Most patients fell within the subgroup with lowest risk (57% of the elective surgery group with 5.6% risk and 91% of the non-elective surgery group with 9.9% risk). Modelled cost-utility ratios were acceptable for only one group of high risk patients undergoing non-elective surgery (only one patient in audit data). Restricting the number of DES for each patient improved results marginally: 4% of stents could then be drug eluting on economic grounds. The threshold price premium justifying 90% substitution of conventional stents was estimated to be 112 pound sterling (212 USD, 162 pound sterling) (sirolimus stents) or 89 pound sterling (167 USD, 130 pound sterling) (paclitaxel stents). At current UK prices, DES are not cost effective compared with conventional stents except for a small minority of patients. Although the technology is clearly effective, general substitution is not justified unless the price premium falls substantially.

  5. Impact evaluation of environmental factors on respiratory function of asthma patients living in urban territory.

    PubMed

    Veremchuk, Lyudmila V; Tsarouhas, Konstantinos; Vitkina, Tatyana I; Mineeva, Elena E; Gvozdenko, Tatyana A; Antonyuk, Marina V; Rakitskii, Valeri N; Sidletskaya, Karolina A; Tsatsakis, Aristidis M; Golokhvast, Kirill S

    2018-04-01

    Environmental pollution, local climatic conditions and their association with the prevalence and exacerbation of asthma are topics of intense current medical investigation. Air pollution in the area of Vladivostock was estimated both by the index of emission volumes of "air gaseous components" (nitrogen oxide and nitrogen dioxide, formaldehyde, hydrogen sulfide, carbon monoxide) in urban atmosphere and by mass spectrometric analysis of precipitates in snow samples. A total of 172 local asthma patients (101 controlled-asthma patients-CAP and 71 non-controlled asthma patients - nCAP) were evaluated with the use of spirometry and body plethysmography. Airway obstruction reversibility was evaluated with the use of an inhaled bronchodilator. Using discriminant analysis the association of environmental parameters with clinical indices of asthma patients is explored and thresholds of impact are established. CAP presented high sensitivity to large-size suspended air particles and to several of the studied climatic parameters. Discriminant analysis showed high values of Wilks' lambda index (α = 0.69-0.81), which implies limited influence of environmental factors on the respiratory parameters of CAP. nCAP were more sensitive and susceptible to the majority of the environmental factors studied, including air suspended toxic metals particles (Cr, Zn and Ni). Air suspended particles showed higher tendency for pathogenicity in nCAP population than in the CAP, with a wider range of particle sizes being involved. Dust fractions ranging from 0 to 1 μm and from 50 to 100 μm were additionally implicated compared to CAP group. Considerably lowest thresholds levels of impact are calculated for nCAP. Copyright © 2017. Published by Elsevier Ltd.

  6. Photo-assisted etching of silicon in chlorine- and bromine-containing plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Weiye; Sridhar, Shyam; Liu, Lei

    2014-05-28

    Cl{sub 2}, Br{sub 2}, HBr, Br{sub 2}/Cl{sub 2}, and HBr/Cl{sub 2} feed gases diluted in Ar (50%–50% by volume) were used to study etching of p-type Si(100) in a rf inductively coupled, Faraday-shielded plasma, with a focus on the photo-assisted etching component. Etching rates were measured as a function of ion energy. Etching at ion energies below the threshold for ion-assisted etching was observed in all cases, with Br{sub 2}/Ar and HBr/Cl{sub 2}/Ar plasmas having the lowest and highest sub-threshold etching rates, respectively. Sub-threshold etching rates scaled with the product of surface halogen coverage (measured by X-ray photoelectron spectroscopy) andmore » Ar emission intensity (7504 Å). Etching rates measured under MgF{sub 2}, quartz, and opaque windows showed that sub-threshold etching is due to photon-stimulated processes on the surface, with vacuum ultraviolet photons being much more effective than longer wavelengths. Scanning electron and atomic force microscopy revealed that photo-etched surfaces were very rough, quite likely due to the inability of the photo-assisted process to remove contaminants from the surface. Photo-assisted etching in Cl{sub 2}/Ar plasmas resulted in the formation of 4-sided pyramidal features with bases that formed an angle of 45° with respect to 〈110〉 cleavage planes, suggesting that photo-assisted etching can be sensitive to crystal orientation.« less

  7. Discrimination of sound source velocity in human listeners

    NASA Astrophysics Data System (ADS)

    Carlile, Simon; Best, Virginia

    2002-02-01

    The ability of six human subjects to discriminate the velocity of moving sound sources was examined using broadband stimuli presented in virtual auditory space. Subjects were presented with two successive stimuli moving in the frontal horizontal plane level with the ears, and were required to judge which moved the fastest. Discrimination thresholds were calculated for reference velocities of 15, 30, and 60 degrees/s under three stimulus conditions. In one condition, stimuli were centered on 0° azimuth and their duration varied randomly to prevent subjects from using displacement as an indicator of velocity. Performance varied between subjects giving median thresholds of 5.5, 9.1, and 14.8 degrees/s for the three reference velocities, respectively. In a second condition, pairs of stimuli were presented for a constant duration and subjects would have been able to use displacement to assist their judgment as faster stimuli traveled further. It was found that thresholds decreased significantly for all velocities (3.8, 7.1, and 9.8 degrees/s), suggesting that the subjects were using the additional displacement cue. The third condition differed from the second in that the stimuli were ``anchored'' on the same starting location rather than centered on the midline, thus doubling the spatial offset between stimulus endpoints. Subjects showed the lowest thresholds in this condition (2.9, 4.0, and 7.0 degrees/s). The results suggested that the auditory system is sensitive to velocity per se, but velocity comparisons are greatly aided if displacement cues are present.

  8. STABILITY AND STOICHIOMETRY OF BILAYER PHOSPHOLIPID-CHOLESTEROL COMPLEXES: RELATIONSHIP TO CELLULAR STEROL DISTRIBUTION AND HOMEOSTASIS&

    PubMed Central

    Lange, Yvonne; Ali Tabei, S. M.; Ye, Jin; Steck, Theodore L.

    2013-01-01

    Does cholesterol distribute among intracellular compartments by passive equilibration down its chemical gradient? If so, its distribution should reflect the relative cholesterol affinity of the constituent membrane phospholipids as well as their ability to form stoichiometric cholesterol complexes. We tested this hypothesis by analyzing the reactivity to cholesterol oxidase of large unilamellar vesicles (LUVs) containing biological phospholipids plus varied cholesterol. The rates of cholesterol oxidation differed among the various phospholipid environments by roughly four orders of magnitude. Furthermore, accessibility to the enzyme increased by orders of magnitude at cholesterol thresholds that suggested stoichiometries of association of 1:1, 2:3 or 1:2 cholesterol:phospholipid (mol:mol). Cholesterol accessibility above the threshold was still constrained by its particular phospholipid environment. One phospholipid, 1-stearoyl-2-oleoyl-sn-glycero-3-phosphatidylserine, exhibited no threshold. The analysis suggested values for the relative stabilities of the cholesterol-phospholipid complexes and for the fractions of bilayer cholesterol not in complexes at the threshold equivalence points; predictably, the saturated phosphorylcholine species had the lowest stoichiometries and the strongest affinities for cholesterol. These results were in general agreement with the equilibrium distribution of cholesterol between the various LUVs and methyl-β-cyclodextrin. In addition, the properties of the cholesterol in intact human red blood cells matched predictions made from LUVs of the corresponding composition. These results support a passive mechanism for the intracellular distribution of cholesterol that can provide a signal for its homeostatic regulation. PMID:24000774

  9. Olfactory Sensitivity and Odor Structure-Activity Relationships for Aliphatic Carboxylic Acids in CD-1 Mice

    PubMed Central

    Can Güven, Selçuk; Laska, Matthias

    2012-01-01

    Using a conditioning paradigm, the olfactory sensitivity of CD-1 mice for a homologous series of aliphatic n-carboxylic acids (ethanoic acid to n-octanoic acid) and several of their isomeric forms was investigated. With all 14 odorants, the animals significantly discriminated concentrations as low as 0.03 ppm (parts per million) from the solvent, and with four odorants the best-scoring animals even detected concentrations as low as 3 ppt (parts per trillion). Analysis of odor structure-activity relationships showed that the correlation between olfactory detection thresholds of the mice for the unbranched carboxylic acids and carbon chain length can best be described as a U-shaped function with the lowest threshold values at n-butanoic acid. A significant positive correlation between olfactory detection thresholds and carbon chain length of the carboxylic acids with their branching next to the functional carboxyl group was found. In contrast, no such correlation was found for carboxylic acids with their branching at the distal end of the carbon chain relative to the functional carboxyl group. Finally, a significant correlation was found between olfactory detection thresholds and the position of the branching of the carboxylic acids. Across-species comparisons suggest that mice are more sensitive for short-chained (C2 to C4) aliphatic n-carboxylic acids than other mammalian species, but not for longer-chained ones (C5 to C8). Further comparisons suggest that odor structure-activity relationships are both substance class- and species-specific. PMID:22479594

  10. Nuclear structure beyond the neutron drip line. The lowest energy states in 9He via their T=5/2 isobaric analogs in 9Li

    DOE PAGES

    Uberseder, E.; Rogachev, G. V.; Goldberg, V. Z.; ...

    2016-03-01

    The level structure of the very neutron rich and unbound 9He nucleus has been the subject of significant experimental and theoretical study. Many recent works have claimed that the two lowest energy 9He states exist with spins J π=1/2 +and Jπ=1/2 -and widths on the order of 100–200 keV. These find-ings cannot be reconciled with our contemporary understanding of nuclear structure. Our present work is the first high-resolution study with low statistical uncertainty of the relevant excitation energy range in the 8He+n system, performed via a search for the T =5/2 isobaric analog states in 9Li populated through 8He+p elasticmore » scattering. Moreover, the present data show no indication of any narrow structures. Instead, we find evidence for a broad J π=1/2 +state in 9He located approximately 3 MeV above the neutron decay threshold.« less

  11. Cortical activation following chronic passive implantation of a wide-field suprachoroidal retinal prosthesis

    NASA Astrophysics Data System (ADS)

    Villalobos, Joel; Fallon, James B.; Nayagam, David A. X.; Shivdasani, Mohit N.; Luu, Chi D.; Allen, Penelope J.; Shepherd, Robert K.; Williams, Chris E.

    2014-08-01

    Objective. The research goal is to develop a wide-field retinal stimulating array for prosthetic vision. This study aimed at evaluating the efficacy of a suprachoroidal electrode array in evoking visual cortex activity after long term implantation. Approach. A planar silicone based electrode array (8 mm × 19 mm) was implanted into the suprachoroidal space in cats (ntotal = 10). It consisted of 20 platinum stimulating electrodes (600 μm diameter) and a trans-scleral cable terminated in a subcutaneous connector. Three months after implantation (nchronic = 6), or immediately after implantation (nacute = 4), an electrophysiological study was performed. Electrode total impedance was measured from voltage transients using 500 μs, 1 mA pulses. Electrically evoked potentials (EEPs) and multi-unit activity were recorded from the visual cortex in response to monopolar retinal stimulation. Dynamic range and cortical activation spread were calculated from the multi-unit recordings. Main results. The mean electrode total impedance in vivo following 3 months was 12.5 ± 0.3 kΩ. EEPs were recorded for 98% of the electrodes. The median evoked potential threshold was 150 nC (charge density 53 μC cm-2). The lowest stimulation thresholds were found proximal to the area centralis. Mean thresholds from multiunit activity were lower for chronic (181 ± 14 nC) compared to acute (322 ± 20 nC) electrodes (P < 0.001), but there was no difference in dynamic range or cortical activation spread. Significance. Suprachoroidal stimulation threshold was lower in chronic than acute implantation and was within safe charge limits for platinum. Electrode-tissue impedance following chronic implantation was higher, indicating the need for sufficient compliance voltage (e.g. 12.8 V for mean impedance, threshold and dynamic range). The wide-field suprachoroidal array reliably activated the retina after chronic implantation.

  12. The effect of culture on pain sensitivity.

    PubMed

    Al-Harthy, M; Ohrbach, R; Michelotti, A; List, T

    2016-02-01

    Cross-cultural differences in pain sensitivity have been identified in pain-free subjects as well as in chronic pain patients. The aim was to assess the impact of culture on psychophysical measures using mechanical and electrical stimuli in patients with temporomandibular disorder (TMD) pain and pain-free matched controls in three cultures. This case-control study compared 122 female cases of chronic TMD pain (39 Saudis, 41 Swedes and 42 Italians) with equal numbers of age- and gender-matched TMD-free controls. Pressure pain threshold (PPT) and tolerance (PPTo) were measured over one hand and two masticatory muscles. Electrical perception threshold and electrical pain threshold (EPT) and tolerance (EPTo) were recorded between the thumb and index fingers. Italian females reported significantly lower PPT in the masseter muscle than other cultures (P < 0.001) and in the temporalis muscle than Saudis (P = 0.003). Swedes reported significantly higher PPT in the thenar muscle than other cultures (P = 0.017). Italians reported significantly lower PPTo in all muscles than Swedes (P ≤ 0.006) and in the masseter muscle than Saudis (P < 0.001). Italians reported significantly lower EPTo than other cultures (P = 0.01). Temporomandibular disorder cases, compared to TMD-free controls, reported lower PPT and PPTo in all the three muscles (P < 0.001). This study found cultural differences between groups in the PPT, PPTo and EPTo. Overall, Italian females reported the highest sensitivity to both mechanical and electrical stimulation, while Swedes reported the lowest sensitivity. Mechanical pain thresholds differed more across cultures than did electrical pain thresholds. Cultural factors may influence response to type of pain test. © 2015 John Wiley & Sons Ltd.

  13. Cut points of muscle strength associated with metabolic syndrome in men.

    PubMed

    Sénéchal, Martin; McGavock, Jonathan M; Church, Timothy S; Lee, Duck-Chul; Earnest, Conrad P; Sui, Xuemei; Blair, Steven N

    2014-08-01

    The loss of muscle strength with age increases the likelihood of chronic conditions, including metabolic syndrome (MetS). However, the minimal threshold of muscle strength at which the risk for MetS increases has never been established. This study aimed to identify a threshold of muscle strength associated with MetS in men. We created receiver operating curves for muscle strength and the risk of MetS from a cross-sectional sample of 5685 men age <50 yr and 1541 men age ≥50 yr enrolled in the Aerobics Center Longitudinal Study. The primary outcome measure, the MetS, was defined according to the National Cholesterol Education Program Adult Treatment Panel III criteria. Upper and lower body muscle strength was treated as a composite measure of one-repetition maximum tests on bench and leg press and scaled to body weight. Low muscle strength was defined as the lowest age-specific 20th percentile, whereas high muscle strength was defined as composite muscle strength above the 20th percentile. In men aged <50 yr, the odds of MetS were 2.20-fold (95% confidence interval = 1.89-2.54) higher in those with low muscle strength, independent of age, smoking, and alcohol intake. The strength of this association was similar for men age ≥50 yr (odds ratio = 2.11, 95% confidence interval = 1.62-2.74). In men age < 50 yr, the composite strength threshold associated with MetS was 2.57 kg·kg body weight, whereas in men age ≥ 50 yr the threshold was 2.35 kg·kg body weight. This study is the first to identify a threshold of muscle strength associated with an increased likelihood of MetS in men. Measures of muscle strength may help identify men at risk of chronic disease.

  14. Viral Load Criteria and Threshold Optimization to Improve HIV Incidence Assay Characteristics - A CEPHIA Analysis

    PubMed Central

    Kassanjee, Reshma; Pilcher, Christopher D; Busch, Michael P; Murphy, Gary; Facente, Shelley N; Keating, Sheila M; Mckinney, Elaine; Marson, Kara; Price, Matthew A; Martin, Jeffrey N; Little, Susan J; Hecht, Frederick M; Kallas, Esper G; Welte, Alex

    2016-01-01

    Objective Assays for classifying HIV infections as ‘recent’ or ‘non-recent’ for incidence surveillance fail to simultaneously achieve large mean durations of ‘recent’ infection (MDRIs) and low ‘false-recent’ rates (FRRs), particularly in virally suppressed persons. The potential for optimizing recent infection testing algorithms (RITAs), by introducing viral load criteria and tuning thresholds used to dichotomize quantitative measures, is explored. Design The Consortium for the Evaluation and Performance of HIV Incidence Assays characterized over 2000 possible RITAs constructed from seven assays (LAg, BED, Less-sensitive Vitros, Vitros Avidity, BioRad Avidity, Architect Avidity and Geenius) applied to 2500 diverse specimens. Methods MDRIs were estimated using regression, and FRRs as observed ‘recent’ proportions, in various specimen sets. Context-specific FRRs were estimated for hypothetical scenarios. FRRs were made directly comparable by constructing RITAs with the same MDRI through the tuning of thresholds. RITA utility was summarized by the precision of incidence estimation. Results All assays produce high FRRs amongst treated subjects and elite controllers (10%-80%). Viral load testing reduces FRRs, but diminishes MDRIs. Context-specific FRRs vary substantially by scenario – BioRad Avidity and LAg provided the lowest FRRs and highest incidence precision in scenarios considered. Conclusions The introduction of a low viral load threshold provides crucial improvements in RITAs. However, it does not eliminate non-zero FRRs, and MDRIs must be consistently estimated. The tuning of thresholds is essential for comparing and optimizing the use of assays. The translation of directly measured FRRs into context-specific FRRs critically affects their magnitudes and our understanding of the utility of assays. PMID:27454561

  15. The Actions of Lyophilized Apple Peel on the Electrical Activity and Organization of the Ventricular Syncytium of the Hearts of Diabetic Rats

    PubMed Central

    Martínez-Ladrón de Guevara, Elideth; Pérez-Hernández, Nury; Villalobos-López, Miguel Ángel; Pérez-Ishiwara, David Guillermo; Salas-Benito, Juan Santiago; Martínez Martínez, Alejandro; Hernández-García, Vicente

    2016-01-01

    This study was designed to examine the effects of lyophilized red delicious apple peel (RDP) on the action potentials (APs) and the input resistance-threshold current relationship. The experiments were performed on isolated papillary heart muscles from healthy male rats, healthy male rats treated with RDP, diabetic male rats, and diabetic male rats treated with RDP. The preparation was superfused with oxygenated Tyrode's solution at 37°C. The stimulation and the recording of the APs, the input resistance, and the threshold current were made using conventional electrophysiological methods. The RDP presented no significant effect in normal rats. Equivalent doses in diabetic rats reduced the APD and ARP. The relationship between input resistance and threshold current established an inverse correlation. The results indicate the following: (1) The functional structure of the cardiac ventricular syncytium in healthy rats is heterogeneous, in terms of input resistance and threshold current. Diabetes further accentuates the heterogeneity. (2) As a consequence, conduction block occurs and increases the possibility of reentrant arrhythmias. (3) These modifications in the ventricular syncytium, coupled with the increase in the ARP, are the adequate substrate so that, with diabetes, the heart becomes more arrhythmogenic. (4) RDP decreases the APD, the ARP, and most syncytium irregularity caused by diabetes. PMID:26839897

  16. [Protective effect of Uncaria rhynchophylla total alkaloids pretreatment on hippocampal neurons after acute hypoxia].

    PubMed

    Liu, Wei; Zhang, Zhao-qin; Zhao, Xiao-min; Gao, Yun-sheng

    2006-05-01

    To investigate the effect of Uncaria rhynchophylla total alkaloids (RTA) pretreatment on the voltage-gated sodium currents of the rat hippocampal neurons after acute hypoxia. Primary cultured hippocampal neurons were divided into RTA pre-treated and non-pretreated groups. Patch clamp whole-cell recording was used to compare the voltage-gated sodium current amplitude and threshold with those before hypoxia. After acute hypoxia, sodium current amplitude was significantly decreased and its threshold was upside. RTA pretreatment could inhibit the reduction of sodium current amplitude. RTA pretreatment alleviates the acute hypoxia-induced change of sodium currents, which may be one of the mechanisms for protective effect of RTA on cells.

  17. Computational analysis of thresholds for magnetophosphenes

    NASA Astrophysics Data System (ADS)

    Laakso, Ilkka; Hirata, Akimasa

    2012-10-01

    In international guidelines, basic restriction limits on the exposure of humans to low-frequency magnetic and electric fields are set with the objective of preventing the generation of phosphenes, visual sensations of flashing light not caused by light. Measured data on magnetophosphenes, i.e. phosphenes caused by a magnetically induced electric field on the retina, are available from volunteer studies. However, there is no simple way for determining the retinal threshold electric field or current density from the measured threshold magnetic flux density. In this study, the experimental field configuration of a previous study, in which phosphenes were generated in volunteers by exposing their heads to a magnetic field between the poles of an electromagnet, is computationally reproduced. The finite-element method is used for determining the induced electric field and current in five different MRI-based anatomical models of the head. The direction of the induced current density on the retina is dominantly radial to the eyeball, and the maximum induced current density is observed at the superior and inferior sides of the retina, which agrees with literature data on the location of magnetophosphenes at the periphery of the visual field. On the basis of computed data, the macroscopic retinal threshold current density for phosphenes at 20 Hz can be estimated as 10 mA m-2 (-20% to  + 30%, depending on the anatomical model); this current density corresponds to an induced eddy current of 14 μA (-20% to  + 10%), and about 20% of this eddy current flows through each eye. The ICNIRP basic restriction limit for the induced electric field in the case of occupational exposure is not exceeded until the magnetic flux density is about two to three times the measured threshold for magnetophosphenes, so the basic restriction limit does not seem to be conservative. However, the reasons for the non-conservativeness are purely technical: removal of the highest 1% of electric field values by taking the 99th percentile as recommended by the ICNIRP leads to the underestimation of the induced electric field, and there are difficulties in applying the basic restriction limit for the retinal electric field.

  18. Error minimization algorithm for comparative quantitative PCR analysis: Q-Anal.

    PubMed

    OConnor, William; Runquist, Elizabeth A

    2008-07-01

    Current methods for comparative quantitative polymerase chain reaction (qPCR) analysis, the threshold and extrapolation methods, either make assumptions about PCR efficiency that require an arbitrary threshold selection process or extrapolate to estimate relative levels of messenger RNA (mRNA) transcripts. Here we describe an algorithm, Q-Anal, that blends elements from current methods to by-pass assumptions regarding PCR efficiency and improve the threshold selection process to minimize error in comparative qPCR analysis. This algorithm uses iterative linear regression to identify the exponential phase for both target and reference amplicons and then selects, by minimizing linear regression error, a fluorescence threshold where efficiencies for both amplicons have been defined. From this defined fluorescence threshold, cycle time (Ct) and the error for both amplicons are calculated and used to determine the expression ratio. Ratios in complementary DNA (cDNA) dilution assays from qPCR data were analyzed by the Q-Anal method and compared with the threshold method and an extrapolation method. Dilution ratios determined by the Q-Anal and threshold methods were 86 to 118% of the expected cDNA ratios, but relative errors for the Q-Anal method were 4 to 10% in comparison with 4 to 34% for the threshold method. In contrast, ratios determined by an extrapolation method were 32 to 242% of the expected cDNA ratios, with relative errors of 67 to 193%. Q-Anal will be a valuable and quick method for minimizing error in comparative qPCR analysis.

  19. Modulation frequency discrimination with single and multiple channels in cochlear implant users

    PubMed Central

    Galvin, John J.; Oba, Sandy; Başkent, Deniz; Fu, Qian-Jie

    2015-01-01

    Temporal envelope cues convey important speech information for cochlear implant (CI) users. Many studies have explored CI users’ single-channel temporal envelope processing. However, in clinical CI speech processors, temporal envelope information is processed by multiple channels. Previous studies have shown that amplitude modulation frequency discrimination (AMFD) thresholds are better when temporal envelopes are delivered to multiple rather than single channels. In clinical fitting, current levels on single channels must often be reduced to accommodate multi-channel loudness summation. As such, it is unclear whether the multi-channel advantage in AMFD observed in previous studies was due to coherent envelope information distributed across the cochlea or to greater loudness associated with multi-channel stimulation. In this study, single- and multi-channel AMFD thresholds were measured in CI users. Multi-channel component electrodes were either widely or narrowly spaced to vary the degree of overlap between neural populations. The reference amplitude modulation (AM) frequency was 100 Hz, and coherent modulation was applied to all channels. In Experiment 1, single- and multi-channel AMFD thresholds were measured at similar loudness. In this case, current levels on component channels were higher for single- than for multi-channel AM stimuli, and the modulation depth was approximately 100% of the perceptual dynamic range (i.e., between threshold and maximum acceptable loudness). Results showed no significant difference in AMFD thresholds between similarly loud single- and multi-channel modulated stimuli. In Experiment 2, single- and multi-channel AMFD thresholds were compared at substantially different loudness. In this case, current levels on component channels were the same for single-and multi-channel stimuli (“summation-adjusted” current levels) and the same range of modulation (in dB) was applied to the component channels for both single- and multi-channel testing. With the summation-adjusted current levels, loudness was lower with single than with multiple channels and the AM depth resulted in substantial stimulation below single-channel audibility, thereby reducing the perceptual range of AM. Results showed that AMFD thresholds were significantly better with multiple channels than with any of the single component channels. There was no significant effect of the distribution of electrodes on multi-channel AMFD thresholds. The results suggest that increased loudness due to multi-channel summation may contribute to the multi-channel advantage in AMFD, and that that overall loudness may matter more than the distribution of envelope information in the cochlea. PMID:25746914

  20. Self-assembled GaInNAs/GaAsN quantum dot lasers: solid source molecular beam epitaxy growth and high-temperature operation

    PubMed Central

    Liu, CY; Sun, ZZ; Yew, KC

    2006-01-01

    Self-assembled GaInNAs quantum dots (QDs) were grown on GaAs (001) substrate using solid-source molecular-beam epitaxy (SSMBE) equipped with a radio-frequency nitrogen plasma source. The GaInNAs QD growth characteristics were extensively investigated using atomic-force microscopy (AFM), photoluminescence (PL), and transmission electron microscopy (TEM) measurements. Self-assembled GaInNAs/GaAsN single layer QD lasers grown using SSMBE have been fabricated and characterized. The laser worked under continuous wave (CW) operation at room temperature (RT) with emission wavelength of 1175.86 nm. Temperature-dependent measurements have been carried out on the GaInNAs QD lasers. The lowest obtained threshold current density in this work is ∼1.05 kA/cm2from a GaInNAs QD laser (50 × 1,700 µm2) at 10 °C. High-temperature operation up to 65 °C was demonstrated from an unbonded GaInNAs QD laser (50 × 1,060 µm2), with high characteristic temperature of 79.4 K in the temperature range of 10–60 °C.

  1. Cost-effectiveness of oral agents in relapsing-remitting multiple sclerosis compared to interferon-based therapy in Saudi Arabia.

    PubMed

    Alsaqa'aby, Mai F; Vaidya, Varun; Khreis, Noura; Khairallah, Thamer Al; Al-Jedai, Ahmed H

    2017-01-01

    Promising clinical and humanistic outcomes are associated with the use of new oral agents in the treatment of relapsing-remitting multiple sclerosis (RRMS). This is the first cost-effectiveness study comparing these medications in Saudi Arabia. We aimed to compare the cost-effectiveness of fingolimod, teriflunomide, dimethyl fumarate, and interferon (IFN)-b1a products (Avonex and Rebif) as first-line therapies in the treatment of patients with RRMS from a Saudi payer perspective. Cohort Simulation Model (Markov Model). Tertiary care hospital. A hypothetical cohort of 1000 RRMS Saudi patients was assumed to enter a Markov model model with a time horizon of 20 years and an annual cycle length. The model was developed based on an expanded disability status scale (EDSS) to evaluate the cost-effectiveness of the five disease-modifying drugs (DMDs) from a healthcare system perspective. Data on EDSS progression and relapse rates were obtained from the literature; cost data were obtained from King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia. Results were expressed as incremental cost-effectiveness ratios (ICERs) and net monetary benefits (NMB) in Saudi Riyals and converted to equivalent $US. The base-case willingness-to-pay (WTP) threshold was assumed to be $100000 (SAR375000). One-way sensitivity analysis and probabilistic sensitivity analysis were conducted to test the robustness of the model. ICERs and NMB. The base-case analysis results showed Rebif as the optimal therapy at a WTP threshold of $100000. Avonex had the lowest ICER value of $337282/QALY when compared to Rebif. One-way sensitivity analysis demonstrated that the results were sensitive to utility weights of health state three and four and the cost of Rebif. None of the DMDs were found to be cost-effective in the treatment of RRMS at a WTP threshold of $100000 in this analysis. The DMDs would only be cost-effective at a WTP above $300000. The current analysis did not reflect the Saudi population preference in valuation of health states and did not consider the societal perspective in terms of cost.

  2. Hypoalgesia in response to transcutaneous electrical nerve stimulation (TENS) depends on stimulation intensity.

    PubMed

    Moran, Fidelma; Leonard, Tracey; Hawthorne, Stephanie; Hughes, Ciara M; McCrum-Gardner, Evie; Johnson, Mark I; Rakel, Barbara A; Sluka, Kathleen A; Walsh, Deirdre M

    2011-08-01

    Transcutaneous electrical nerve stimulation (TENS) is an electrophysical modality used for pain management. This study investigated the dose response of different TENS intensities on experimentally induced pressure pain. One hundred and thirty TENS naïve healthy individuals (18-64 years old; 65 males, 65 females) were randomly allocated to 5 groups (n = 26 per group): Strong Non Painful TENS; Sensory Threshold TENS; Below Sensory Threshold TENS; No Current Placebo TENS; and Transient Placebo TENS. Active TENS (80 Hz) was applied to the forearm for 30 minutes. Transient Placebo TENS was applied for 42 seconds after which the current amplitude automatically reset to 0 mA. Pressure pain thresholds (PPT) were recorded from 2 points on the hand and forearm before and after TENS to measure hypoalgesia. There were significant differences between groups at both the hand and forearm (ANOVA; P = .005 and .002). At 30 minutes, there was a significant hypoalgesic effect in the Strong Non Painful TENS group compared to: Below Sensory Threshold TENS, No Current Placebo TENS and Transient Placebo TENS groups (P < .0001) at the forearm; Transient Placebo TENS and No Current Placebo TENS groups at the hand (P = .001). There was no significant difference between Strong Non Painful TENS and Sensory Threshold TENS groups. The area under the curve for the changes in PPT significantly correlated with the current amplitude (r(2) = .33, P = .003). These data therefore show that there is a dose-response effect of TENS with the largest effect occurring with the highest current amplitudes. This study shows a dose response for the intensity of TENS for pain relief with the strongest intensities showing the greatest effect; thus, we suggest that TENS intensity should be titrated to achieve the strongest possible intensity to achieve maximum pain relief. Copyright © 2011 American Pain Society. Published by Elsevier Inc. All rights reserved.

  3. System and method for quench and over-current protection of superconductor

    DOEpatents

    Huang, Xianrui; Laskaris, Evangelos Trifon; Sivasubramaniam, Kiruba Haran; Bray, James William; Ryan, David Thomas; Fogarty, James Michael; Steinbach, Albert Eugene

    2005-05-31

    A system and method for protecting a superconductor. The system may comprise a current sensor operable to detect a current flowing through the superconductor. The system may comprise a coolant temperature sensor operable to detect the temperature of a cryogenic coolant used to cool the superconductor to a superconductive state. The control circuit is operable to estimate the superconductor temperature based on the current flow and the coolant temperature. The system may also be operable to compare the estimated superconductor temperature to at least one threshold temperature and to initiate a corrective action when the superconductor temperature exceeds the at least one threshold temperature.

  4. Effects of N-Acetylcysteine on Thresholds and Otoacoustic Emissions Following Noise Exposure

    DTIC Science & Technology

    2004-12-01

    EFFECTS OF N- ACETYLCYSTEINE ON THRESHOLDS AND OTOACOUSTIC EMISSIONS FOLLOWING NOISE EXPOSURE Barbara Acker-Mills, Ph.D*., CPT Martin Robinette...wearing ear plugs, muffs, etc.. The current study evaluated the effectiveness of one antioxidant, N- acetylcysteine (NAC), on temporary cochlear changes...4. TITLE AND SUBTITLE Effects Of N- Acetylcysteine On Thresholds And Otoacoustic Emissions Following Noise Exposure 5a. CONTRACT NUMBER 5b

  5. Threshold-Voltage-Shift Compensation and Suppression Method Using Hydrogenated Amorphous Silicon Thin-Film Transistors for Large Active Matrix Organic Light-Emitting Diode Displays

    NASA Astrophysics Data System (ADS)

    Oh, Kyonghwan; Kwon, Oh-Kyong

    2012-03-01

    A threshold-voltage-shift compensation and suppression method for active matrix organic light-emitting diode (AMOLED) displays fabricated using a hydrogenated amorphous silicon thin-film transistor (TFT) backplane is proposed. The proposed method compensates for the threshold voltage variation of TFTs due to different threshold voltage shifts during emission time and extends the lifetime of the AMOLED panel. Measurement results show that the error range of emission current is from -1.1 to +1.7% when the threshold voltage of TFTs varies from 1.2 to 3.0 V.

  6. Acute effect of ozone exposure on daily mortality in seven cities of Jiangsu Province, China: No clear evidence for threshold.

    PubMed

    Chen, Kai; Zhou, Lian; Chen, Xiaodong; Bi, Jun; Kinney, Patrick L

    2017-05-01

    Few multicity studies have addressed the health effects of ozone in China due to the scarcity of ozone monitoring data. A critical scientific and policy-relevant question is whether a threshold exists in the ozone-mortality relationship. Using a generalized additive model and a univariate random-effects meta-analysis, this research evaluated the relationship between short-term ozone exposure and daily total mortality in seven cities of Jiangsu Province, China during 2013-2014. Spline, subset, and threshold models were applied to further evaluate whether a safe threshold level exists. This study found strong evidence that short-term ozone exposure is significantly associated with premature total mortality. A 10μg/m 3 increase in the average of the current and previous days' maximum 8-h average ozone concentration was associated with a 0.55% (95% posterior interval: 0.34%, 0.76%) increase of total mortality. This finding is robust when considering the confounding effect of PM 2.5 , PM 10 , NO 2 , and SO 2 . No consistent evidence was found for a threshold in the ozone-mortality concentration-response relationship down to concentrations well below the current Chinese Ambient Air Quality Standard (CAAQS) level 2 standard (160μg/m 3 ). Our findings suggest that ozone concentrations below the current CAAQS level 2 standard could still induce increased mortality risks in Jiangsu Province, China. Continuous air pollution control measures could yield important health benefits in Jiangsu Province, China, even in cities that meet the current CAAQS level 2 standard. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Acute effect of ozone exposure on daily mortality in seven cities of Jiangsu Province, China: No clear evidence for threshold

    PubMed Central

    Chen, Kai; Zhou, Lian; Chen, Xiaodong; Bi, Jun; Kinney, Patrick L.

    2017-01-01

    Background Few multicity studies have addressed the health effects of ozone in China due to the scarcity of ozone monitoring data. A critical scientific and policy-relevant question is whether a threshold exists in the ozone-mortality relationship. Methods Using a generalized additive model and a univariate random-effects meta-analysis, this research evaluated the relationship between short-term ozone exposure and daily total mortality in seven cities of Jiangsu Province, China during 2013–2014. Spline, subset, and threshold models were applied to further evaluate whether a safe threshold level exists. Results This study found strong evidence that short-term ozone exposure is significantly associated with premature total mortality. A 10 μg/m3 increase in the average of the current and previous days’ maximum 8-h average ozone concentration was associated with a 0.55% (95% posterior interval: 0.34%, 0.76%) increase of total mortality. This finding is robust when considering the confounding effect of PM2.5, PM10, NO2, and SO2. No consistent evidence was found for a threshold in the ozone-mortality concentration-response relationship down to concentrations well below the current Chinese Ambient Air Quality Standard (CAAQS) level 2 standard (160 μg/m3). Conclusions Our findings suggest that ozone concentrations below the current CAAQS level 2 standard could still induce increased mortality risks in Jiangsu Province, China. Continuous air pollution control measures could yield important health benefits in Jiangsu Province, China, even in cities that meet the current CAAQS level 2 standard. PMID:28231551

  8. Perspectives on setting limits for RF contact currents: a commentary.

    PubMed

    Tell, Richard A; Tell, Christopher A

    2018-01-15

    Limits for exposure to radiofrequency (RF) contact currents are specified in the two dominant RF safety standards and guidelines developed by the Institute of Electrical and Electronics Engineers (IEEE) and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These limits are intended to prevent RF burns when contacting RF energized objects caused by high local tissue current densities. We explain what contact currents are and review some history of the relevant limits with an emphasis on so-called "touch" contacts, i.e., contact between a person and a contact current source during touch via a very small contact area. Contact current limits were originally set on the basis of controlling the specific absorption rate resulting from the current flowing through regions of small conductive cross section within the body, such as the wrist or ankle. More recently, contact currents have been based on thresholds of perceived heating. In the latest standard from the IEEE developed for NATO, contact currents have been based on two research studies in which thresholds for perception of thermal warmth or thermal pain have been measured. Importantly, these studies maximized conductive contact between the subject and the contact current source. This factor was found to dominate the response to heating wherein high resistance contact, such as from dry skin, can result in local heating many times that from a highly conductive contact. Other factors such as electrode size and shape, frequency of the current and the physical force associated with contact are found to introduce uncertainty in threshold values when comparing data across multiple studies. Relying on studies in which the contact current is minimized for a given threshold does not result in conservative protection limits. Future efforts to develop limits on contact currents should include consideration of (1) the basis for the limits (perception, pain, tissue damage); (2) understanding of the practical conditions of real world exposure for contact currents such as contact resistance, size and shape of the contact electrode and applied force at the point of contact; (3) consistency of how contact currents are applied in research studies across different researchers; (4) effects of frequency.

  9. Impaired taste sensation in type 2 diabetic patients without chronic complications: a case-control study.

    PubMed

    De Carli, L; Gambino, R; Lubrano, C; Rosato, R; Bongiovanni, D; Lanfranco, F; Broglio, F; Ghigo, E; Bo, S

    2017-11-28

    Few and contradictory data suggest changes in taste perception in type 2 diabetes (T2DM), potentially altering food choices. We, therefore, analyzed taste recognition thresholds in T2DM patients with good metabolic control and free of conditions potentially impacting on taste, compared with age-, body mass index-, and sex-matched normoglycemic controls. An ascending-concentration method was used, employing sucrose (sweet), sodium chloride (salty), citric acid (sour), and quinine hydrochloride (bitter), diluted in increasing concentration solutions. The recognition threshold was the lowest concentration of correct taste identification. The recognition thresholds for the four tastes were higher in T2DM patients. In a multiple regression model, T2DM [β = 0.95; 95% CI 0.32-1.58; p = 0.004 (salty); β = 0.61; 0.19-1.03; p = 0.006 (sweet); β = 0.78; 0.15-1.40; p = 0.016 (sour); β = 0.74; 0.22-1.25; p = 0.006 (bitter)] and waist circumference [β = 0.05; 0.01-0.08; p = 0.012 (salty); β = 0.03; 0.01-0.05; p = 0.020 (sweet); β = 0.04; 0.01-0.08; p = 0.020 (sour); β = 0.04; 0.01-0.07; p = 0.007 (bitter)] were associated with the recognition thresholds. Age was associated with salty (β = 0.06; 0.01-0.12; p = 0.027) and BMI with sweet thresholds (β = 0.06; 0.01-0.11; p = 0.019). Taste recognition thresholds were higher in uncomplicated T2DM, and central obesity was significantly associated with this impairment. Hypogeusia may be an early sign of diabetic neuropathy and be implicated in the poor compliance of these patients to dietary recommendations.

  10. Separation of ice crystals from interstitial aerosol particles using virtual impaction at the Fifth International Ice Nucleation Workshop FIN-3

    NASA Astrophysics Data System (ADS)

    Roesch, M.; Garimella, S.; Roesch, C.; Zawadowicz, M. A.; Katich, J. M.; Froyd, K. D.; Cziczo, D. J.

    2016-12-01

    In this study, a parallel-plate ice chamber, the SPectrometer for Ice Nuclei (SPIN, DMT Inc.) was combined with a pumped counterflow virtual impactor (PCVI, BMI Inc.) to separate ice crystals from interstitial aerosol particles by their aerodynamic size. These measurements were part of the FIN-3 workshop, which took place in fall 2015 at Storm Peak Laboratory (SPL), a high altitude mountain top facility (3220 m m.s.l.) in the Rocky Mountains. The investigated particles were sampled from ambient air and were exposed to cirrus-like conditions inside SPIN (-40°C, 130% RHice). Previous SPIN experiments under these conditions showed that ice crystals were found to be in the super-micron range. Connected to the outlet of the ice chamber, the PCVI was adjusted to separate all particulates aerodynamically larger than 3.5 micrometer to the sample flow while smaller ones were rejected and removed by a pump flow. Using this technique reduces the number of interstitial aerosol particles, which could bias subsequent ice nucleating particle (INP) analysis. Downstream of the PCVI, the separated ice crystals were evaporated and the flow with the remaining INPs was split up to a particle analysis by laser mass spectrometry (PALMS) instrument a laser aerosol spectrometer (LAS, TSI Inc.) and a single particle soot photometer (SP2, DMT Inc.). Based on the sample flow and the resolution of the measured particle data, the lowest concentration threshold for the SP2 instrument was 294 INP L-1 and for the LAS instrument 60 INP L-1. Applying these thresholds as filters to the measured PALMS time series 944 valid INP spectra using the SP2 threshold and 445 valid INP spectra using the LAS threshold were identified. A sensitivity study determining the number of good INP spectra as a function of the filter threshold concentration showed a two-phase linear growth when increasing the threshold concentration showing a breakpoint around 100 INP L-1.

  11. Simulated mussel mortality thresholds as a function of mussel biomass and nutrient loading

    USGS Publications Warehouse

    Bril, Jeremy S.; Langenfeld, Kathryn; Just, Craig L.; Spak, Scott N.; Newton, Teresa

    2017-01-01

    A freshwater “mussel mortality threshold” was explored as a function of porewater ammonium (NH4+) concentration, mussel biomass, and total nitrogen (N) utilizing a numerical model calibrated with data from mesocosms with and without mussels. A mortality threshold of 2 mg-N L−1 porewater NH4+ was selected based on a study that estimated 100% mortality of juvenile Lampsilis mussels exposed to 1.9 mg-N L−1NH4+ in equilibrium with 0.18 mg-N L−1 NH3. At the highest simulated mussel biomass (560 g m−2) and the lowest simulated influent water “food” concentration (0.1 mg-N L−1), the porewater NH4+ concentration after a 2,160 h timespan without mussels was 0.5 mg-N L−1 compared to 2.25 mg-N L−1 with mussels. Continuing these simulations while varying mussel biomass and N content yielded a mortality threshold contour that was essentially linear which contradicted the non-linear and non-monotonic relationship suggested by Strayer (2014). Our model suggests that mussels spatially focus nutrients from the overlying water to the sediments as evidenced by elevated porewater NH4+ in mesocosms with mussels. However, our previous work and the model utilized here show elevated concentrations of nitrite and nitrate in overlying waters as an indirect consequence of mussel activity. Even when the simulated overlying water food availability was quite low, the mortality threshold was reached at a mussel biomass of about 480 g m−2. At a food concentration of 10 mg-N L−1, the mortality threshold was reached at a biomass of about 250 g m−2. Our model suggests the mortality threshold for juvenile Lampsilis species could be exceeded at low mussel biomass if exposed for even a short time to the highly elevated total N loadings endemic to the agricultural Midwest.

  12. Predicting reactivity threshold in children with anaphylaxis to peanut.

    PubMed

    Reier-Nilsen, T; Michelsen, M M; Lødrup Carlsen, K C; Carlsen, K-H; Mowinckel, P; Nygaard, U C; Namork, E; Borres, M P; Håland, G

    2018-04-01

    Peanut allergy necessitates dietary restrictions, preferably individualized by determining reactivity threshold through an oral food challenge (OFC). However, risk of systemic reactions often precludes OFC in children with severe peanut allergy. We aimed to determine whether clinical and/or immunological characteristics were associated with reactivity threshold in children with anaphylaxis to peanut and secondarily, to investigate whether these characteristics were associated with severity of the allergic reaction during OFC. A double-blinded placebo-controlled food challenge (DBPCFC) with peanut was performed in 96 5- to 15-year-old children with a history of severe allergic reactions to peanut and/or sensitization to peanut (skin prick test [SPT] ≥3 mm or specific immunoglobulin E [s-IgE] ≥0.35 kUA/L). Investigations preceding the DBPCFC included a structured interview, SPT, lung function measurements, serological immunology assessment (IgE, IgG and IgG 4 ), basophil activation test (BAT) and conjunctival allergen provocation test (CAPT). International standards were used to define anaphylaxis and grade the allergic reaction during OFC. During DBPCFC, all 96 children (median age 9.3, range 5.1-15.2) reacted with anaphylaxis (moderate objective symptoms from at least two organ systems). Basophil activation (CD63 + basophils ≥15%), peanut SPT and the ratio of peanut s-IgE/total IgE were significantly associated with reactivity threshold and lowest observed adverse events level (LOAEL) (all P < .04). Basophil activation best predicted very low threshold level (<3 mg of peanut protein), with an optimal cut-off of 75.8% giving a 93.5% negative predictive value. None of the characteristics were significantly associated with the severity of allergic reaction. In children with anaphylaxis to peanut, basophil activation, peanut SPT and the ratio of peanut s-IgE/total IgE were associated with reactivity threshold and LOAEL, but not with allergy reaction severity. © 2017 John Wiley & Sons Ltd.

  13. Low levels of physical activity are associated with dysregulation of energy intake and fat mass gain over 1 year.

    PubMed

    Shook, Robin P; Hand, Gregory A; Drenowatz, Clemens; Hebert, James R; Paluch, Amanda E; Blundell, John E; Hill, James O; Katzmarzyk, Peter T; Church, Timothy S; Blair, Steven N

    2015-12-01

    Previous studies suggest that appetite may be dysregulated at low levels of activity, creating an energy imbalance that results in weight gain. The aim was to examine the relation between energy intake, physical activity, appetite, and weight gain during a 1-y follow-up period in a large sample of adults. Participants included 421 individuals (mean ± SD age: 27.6 ± 3.8 y). Measurements included the following: energy intake with the use of interviewer-administered dietary recalls and calculated by using changes in body composition and energy expenditure, moderate-to-vigorous physical activity (MVPA) with the use of an arm-based monitor, body composition with the use of dual-energy X-ray absorptiometry, and questionnaire-derived perceptions of dietary restraint, disinhibition, hunger, and control of eating. Participants were grouped at baseline into quintiles of MVPA (min/d) by sex. Measurements were repeated every 3 mo for 1 y. At baseline, an inverse relation existed between body weight and activity groups, with the least-active group (15.7 ± 9.9 min MVPA/d, 6062 ± 1778 steps/d) having the highest body weight (86.3 ± 13.2 kg) and the most-active group (174.5 ± 60.5 min MVPA/d, 10260 ± 3087 steps/d) having the lowest body weight (67.5 ± 11.0 kg). A positive relation was observed between calculated energy intake and activity group, except in the lowest quintile of activity. The lowest physical activity group reported higher levels of disinhibition (P = 0.07) and cravings for savory foods (P = 0.03) compared with the group with the highest level of physical activity. Over 1 y of follow-up, the lowest activity group gained the largest amount of fat mass (1.7 ± 0.3 kg) after adjustment for change in MVPA and baseline fat mass. The odds of gaining >3% of fat mass were between 1.8 and 3.8 times as high for individuals in the least-active group as for those in the middle activity group. These results suggest that low levels of physical activity are a risk factor for fat mass gain. In the current sample, a threshold for achieving energy balance occurred at an activity level corresponding to 7116 steps/d, an amount achievable by most adults. This trial was registered at clinicaltrials.gov as NCT01746186. © 2015 American Society for Nutrition.

  14. Low levels of physical activity are associated with dysregulation of energy intake and fat mass gain over 1 year12

    PubMed Central

    Shook, Robin P; Hand, Gregory A; Drenowatz, Clemens; Hebert, James R; Paluch, Amanda E; Blundell, John E; Hill, James O; Katzmarzyk, Peter T; Church, Timothy S; Blair, Steven N

    2015-01-01

    Background: Previous studies suggest that appetite may be dysregulated at low levels of activity, creating an energy imbalance that results in weight gain. Objective: The aim was to examine the relation between energy intake, physical activity, appetite, and weight gain during a 1-y follow-up period in a large sample of adults. Design: Participants included 421 individuals (mean ± SD age: 27.6 ± 3.8 y). Measurements included the following: energy intake with the use of interviewer-administered dietary recalls and calculated by using changes in body composition and energy expenditure, moderate-to-vigorous physical activity (MVPA) with the use of an arm-based monitor, body composition with the use of dual-energy X-ray absorptiometry, and questionnaire-derived perceptions of dietary restraint, disinhibition, hunger, and control of eating. Participants were grouped at baseline into quintiles of MVPA (min/d) by sex. Measurements were repeated every 3 mo for 1 y. Results: At baseline, an inverse relation existed between body weight and activity groups, with the least-active group (15.7 ± 9.9 min MVPA/d, 6062 ± 1778 steps/d) having the highest body weight (86.3 ± 13.2 kg) and the most-active group (174.5 ± 60.5 min MVPA/d, 10260 ± 3087 steps/d) having the lowest body weight (67.5 ± 11.0 kg). A positive relation was observed between calculated energy intake and activity group, except in the lowest quintile of activity. The lowest physical activity group reported higher levels of disinhibition (P = 0.07) and cravings for savory foods (P = 0.03) compared with the group with the highest level of physical activity. Over 1 y of follow-up, the lowest activity group gained the largest amount of fat mass (1.7 ± 0.3 kg) after adjustment for change in MVPA and baseline fat mass. The odds of gaining >3% of fat mass were between 1.8 and 3.8 times as high for individuals in the least-active group as for those in the middle activity group. Conclusions: These results suggest that low levels of physical activity are a risk factor for fat mass gain. In the current sample, a threshold for achieving energy balance occurred at an activity level corresponding to 7116 steps/d, an amount achievable by most adults. This trial was registered at clinicaltrials.gov as NCT01746186. PMID:26561620

  15. Insufficient evidence to support separate BMI definitions for obesity in children and adolescents from south Asian ethnic groups in the UK.

    PubMed

    Viner, R M; Cole, Tim J; Fry, T; Gupta, S; Kinra, S; McCarthy, D; Saxena, S; Taylor, S; Wells, J C K; Whincup, P; Zaman, M J S

    2010-04-01

    Re-evaluation of adult obesity thresholds in some ethnic groups has led to the questioning of childhood obesity thresholds. An expert group was convened to examine the representativeness of childhood obesity definitions, evidence for ethnic differences in body composition in UK children and the extent of misclassification of adiposity by current body mass index (BMI) thresholds in south Asian and black groups. The group concluded that the current International Obesity Task Force (IOTF) definitions remained the most appropriate for use in the United Kingdom, but further research was needed on the relationship of body shape, fat mass, metabolic markers and ethnicity in children and adolescents.

  16. Empirical estimation of genome-wide significance thresholds based on the 1000 Genomes Project data set.

    PubMed

    Kanai, Masahiro; Tanaka, Toshihiro; Okada, Yukinori

    2016-10-01

    To assess the statistical significance of associations between variants and traits, genome-wide association studies (GWAS) should employ an appropriate threshold that accounts for the massive burden of multiple testing in the study. Although most studies in the current literature commonly set a genome-wide significance threshold at the level of P=5.0 × 10 -8 , the adequacy of this value for respective populations has not been fully investigated. To empirically estimate thresholds for different ancestral populations, we conducted GWAS simulations using the 1000 Genomes Phase 3 data set for Africans (AFR), Europeans (EUR), Admixed Americans (AMR), East Asians (EAS) and South Asians (SAS). The estimated empirical genome-wide significance thresholds were P sig =3.24 × 10 -8 (AFR), 9.26 × 10 -8 (EUR), 1.83 × 10 -7 (AMR), 1.61 × 10 -7 (EAS) and 9.46 × 10 -8 (SAS). We additionally conducted trans-ethnic meta-analyses across all populations (ALL) and all populations except for AFR (ΔAFR), which yielded P sig =3.25 × 10 -8 (ALL) and 4.20 × 10 -8 (ΔAFR). Our results indicate that the current threshold (P=5.0 × 10 -8 ) is overly stringent for all ancestral populations except for Africans; however, we should employ a more stringent threshold when conducting a meta-analysis, regardless of the presence of African samples.

  17. [The new German general threshold limit value for dust--pro and contra the adoption in Austria].

    PubMed

    Godnic-Cvar, Jasminka; Ponocny, Ivo

    2004-01-01

    Since it has been realised that inhalation of inert dust is one of the important confounding variables for the development of chronic bronchitis, the threshold values for occupational exposure to these dusts needs to be further decreased. The German Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK-Commission) has set a new threshold (MAK-Value) for inert dusts (4 mg/m3 for inhalable dust, 1.5 mg/m3 for respirable dust) in 1997. This value is much lower than the threshold values currently used world-wide. The aim of the present article is to assess the scientific plausibility of the methodology (databases and statistics) used to set these new German MAK-Values, regarding their adoption in Austria. Although we believe that it is substantial to lower the MAK-Value for inert dust in order to prevent the development of chronic bronchitis as a consequence of occupational exposure to inert dusts, the applied methodology used by the German MAK-Commission in 1997 to set the new MAK-Values does not justify the reduction of the threshold limit value. A carefully designed study to establish an appropriate scientific basis for setting a new threshold value for inert dusts in the workplace should be carried out. Meanwhile, at least the currently internationally applied threshold values should be adopted in Austria.

  18. Mapping critical loads of nitrogen deposition for aquatic ecosystems in the Rocky Mountains, USA

    USGS Publications Warehouse

    Nanus, Leora; Clow, David W.; Saros, Jasmine E.; Stephens, Verlin C.; Campbell, Donald H.

    2012-01-01

    Spatially explicit estimates of critical loads of nitrogen (N) deposition (CLNdep) for nutrient enrichment in aquatic ecosystems were developed for the Rocky Mountains, USA, using a geostatistical approach. The lowest CLNdep estimates (−1 yr−1) occurred in high-elevation basins with steep slopes, sparse vegetation, and abundance of exposed bedrock and talus. These areas often correspond with areas of high N deposition (>3 kg N ha−1 yr−1), resulting in CLNdep exceedances ≥1.5 ± 1 kg N ha−1 yr−1. CLNdep and CLNdep exceedances exhibit substantial spatial variability related to basin characteristics and are highly sensitive to the NO3− threshold at which ecological effects are thought to occur. Based on an NO3− threshold of 0.5 μmol L−1, N deposition exceeds CLNdep in 21 ± 8% of the study area; thus, broad areas of the Rocky Mountains may be impacted by excess N deposition, with greatest impacts at high elevations.

  19. Mapping critical loads of nitrogen deposition for aquatic ecosystems in the Rocky Mountains, USA

    USGS Publications Warehouse

    Nanus, Leora; Clow, David W.; Saros, Jasmine E.; Stephens, Verlin C.; Campbell, Donald H.

    2012-01-01

    Spatially explicit estimates of critical loads of nitrogen (N) deposition (CLNdep) for nutrient enrichment in aquatic ecosystems were developed for the Rocky Mountains, USA, using a geostatistical approach. The lowest CLNdep estimates (-1 yr-1) occurred in high-elevation basins with steep slopes, sparse vegetation, and abundance of exposed bedrock and talus. These areas often correspond with areas of high N deposition (>3 kg N ha-1 yr-1), resulting in CLNdep exceedances ≥1.5 ± 1 kg N ha-1 yr-1. CLNdep and CLNdep exceedances exhibit substantial spatial variability related to basin characteristics and are highly sensitive to the NO3- threshold at which ecological effects are thought to occur. Based on an NO3- threshold of 0.5 μmol L-1, N deposition exceeds CLNdep in 21 ± 8% of the study area; thus, broad areas of the Rocky Mountains may be impacted by excess N deposition, with greatest impacts at high elevations.

  20. A large surface photomultiplier based on SiPMs

    NASA Astrophysics Data System (ADS)

    Barbarino, Giancarlo; de Asmundis, Riccardo; De Rosa, Gianfranca; Vivolo, Daniele; Mollo, Carlos Maximiliano

    2013-10-01

    Light detection through photosensitive devices represents one of the key issues for a large variety of experiments. In the recent years, Silicon PhotoMultipliers (SiPMs) based on limited Geiger-mode avalanche have been extensively studied in view of their future applications. However, their use is strongly limited by their small sensitive surfaces and by the fact that any increment in the surface turns out into an increase of the dark count rate. In the present work we describe the dark count rate reduction obtained by using a FPGA-based logical circuit for fast pre-processing of pulses from a 3×3 matrix of SiPMs. The prototype we developed supports two SiPMs: we show that a rate reduction from 6.6 Mcps (Mega counts per second) down to 0.436 Mcps at the lowest threshold (0.5 photon-equivalent) and from 1.2 kcps down to 0.02 cps for the highest threshold (3.5 photon-equivalent) is obtainable.

  1. The effects of click and tone-burst stimulus parameters on the vestibular evoked myogenic potential (VEMP).

    PubMed

    Akin, Faith Wurm; Murnane, Owen D; Proffitt, Tina M

    2003-11-01

    Vestibular evoked myogenic potentials (VEMP) are short latency electromyograms (EMG) evoked by high-level acoustic stimuli and recorded from surface electrodes over the tonically contracted sternocleidomastoid (SCM) muscle and are presumed to originate in the saccule. The present experiments examined the effects of click and tone-burst level and stimulus frequency on the latency, amplitude, and threshold of the VEMP in subjects with normal hearing sensitivity and no history of vestibular disease. VEMPs were recorded in all subjects using 100 dB nHL click stimuli. Most subjects had VEMPs present at 500, 750, and 1000 Hz, and few subjects had VEMPs present at 2000 Hz. The response amplitude of the VEMP increased with click and tone-burst level, whereas VEMP latency was not influenced by the stimulus level. The largest tone-burst-evoked VEMPs and lowest thresholds were obtained at 500 and 750 Hz. VEMP latency was independent of stimulus frequency when tone-burst duration was held constant.

  2. Interplay of charge clustering and weak binding in reactions of 8Li

    NASA Astrophysics Data System (ADS)

    Cook, K. J.; Carter, I. P.; Simpson, E. C.; Dasgupta, M.; Hinde, D. J.; Bezzina, L. T.; Kalkal, Sunil; Sengupta, C.; Simenel, C.; Swinton-Bland, B. M. A.; Vo-Phuoc, K.; Williams, E.

    2018-02-01

    In collisions of light, stable, weakly bound nuclides, complete fusion (capture of all of the projectile charge) has been found to be suppressed by ˜30 % at above-barrier energies. This is thought to be related to their low thresholds for breakup into charged clusters. The observation of fusion suppression in the neutron-rich radioactive nucleus 8Li is therefore puzzling: the lowest breakup threshold yields 7Li+n which cannot contribute to fusion suppression because 7Li retains all the projectile charge. In this work, the full characteristics of 8Li breakup in reactions with 209Bi are presented, including, for the first time, coincidence measurements of breakup into charged clusters. Correlations of cluster fragments show that most breakup occurs too slowly to significantly suppress fusion. However, a large cross section for unaccompanied α particles was found, suggesting that charge clustering, facilitating partial charge capture, rather than weak binding is the crucial factor in fusion suppression, which may therefore persist in exotic nuclides.

  3. Does diurnal variation in cough reflex testing exist in healthy young adults?

    PubMed

    Perry, Sarah; Huckabee, Maggie-Lee

    2017-05-01

    The aim of this study was to investigate whether diurnal variation in cough reflex sensitivity exists in healthy young adults when a tidal-breathing method is used. Fifty-three participants (19-37 years) underwent cough reflex testing on two occasions: once in the morning (between 9 am - midday) and once in the afternoon (between 2-5 pm). The order of testing was counter-balanced. Within each assessment, participants inhaled successively higher citric acid concentrations via a facemask, with saline solution randomly interspersed to control for a placebo response. The lowest concentration that elicited a reflexive cough response was recorded. Morning cough thresholds (mean=0.6mol/L) were not different from afternoon cough thresholds (mean=0.6mol/L), p=0.16, T=101, r=-0.14. We found no evidence of diurnal variability in cough reflex testing. There was, however, an order effect irrespective of time of day, confirming that healthy participants are able to volitionally modulate their cough response. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Metalorganic vapor phase epitaxial growth of red and infrared vertical-cavity surface-emitting laser diodes

    NASA Astrophysics Data System (ADS)

    Schneider, R. P.; Lott, J. A.; Lear, K. L.; Choquette, K. D.; Crawford, M. H.; Kilcoyne, S. P.; Figiel, J. J.

    1994-12-01

    Metalorganic vapor phase epitaxy (MOVPE) is used for the growth of vertical-cavity surface-emitting laser (VCSEL) diodes. MOVPE exhibits a number of important advantages over the more commonly-used molecular-beam epitaxial (MBE) techniques, including ease of continuous compositional grading and carbon doping for low-resistance p-type distributed Bragg reflectors (DBRs), higher growth rates for rapid throughput and greater versatility in choice of materials and dopants. Planar gain-guided red VCSELs based on AlGaInP/AlGaAs heterostructures lase continuous-wave at room temperature, with voltage thresholds between 2.5 and 3 V and maximum power outputs of over 0.3 mW. Top-emitting infra-red (IR) VCSELs exhibit the highest power-conversion (wall-plug) efficiencies (21%), lowest threshold voltage (1.47 V), and highest single mode power (4.4 mW from an 8 μm device) yet reported. These results establish MOVPE as a preferred growth technique for this important new family of photonic devices.

  5. Binding of two-electron metastable states in semiconductor quantum dots under a magnetic field

    NASA Astrophysics Data System (ADS)

    Garagiola, Mariano; Pont, Federico M.; Osenda, Omar

    2018-04-01

    Applying a strong enough magnetic field results in the binding of few-electron resonant states. The mechanism was proposed many years ago but its verification in laboratory conditions is far more recent. In this work we study the binding of two-electron resonant states. The electrons are confined in a cylindrical quantum dot which is embedded in a semiconductor wire. The geometry considered is similar to the one used in actual experimental setups. The low-energy two-electron spectrum is calculated numerically from an effective-mass approximation Hamiltonian modelling the system. Methods for binding threshold calculations in systems with one and two electrons are thoroughly studied; in particular, we use quantum information quantities to assess when the strong lateral confinement approximation can be used to obtain reliable low-energy spectra. For simplicity, only cases without bound states in the absence of an external field are considered. Under these conditions, the binding threshold for the one-electron case is given by the lowest Landau energy level. Moreover, the energy of the one-electron bounded resonance can be used to obtain the two-electron binding threshold. It is shown that for realistic values of the two-electron model parameters it is feasible to bind resonances with field strengths of a few tens of tesla.

  6. Wrinkled 2D Materials: A Versatile Platform for Low-Threshold Stretchable Random Lasers.

    PubMed

    Hu, Han-Wen; Haider, Golam; Liao, Yu-Ming; Roy, Pradip Kumar; Ravindranath, Rini; Chang, Huan-Tsung; Lu, Cheng-Hsin; Tseng, Chang-Yang; Lin, Tai-Yung; Shih, Wei-Heng; Chen, Yang-Fang

    2017-11-01

    A stretchable, flexible, and bendable random laser system capable of lasing in a wide range of spectrum will have many potential applications in next- generation technologies, such as visible-spectrum communication, superbright solid-state lighting, biomedical studies, fluorescence, etc. However, producing an appropriate cavity for such a wide spectral range remains a challenge owing to the rigidity of the resonator for the generation of coherent loops. 2D materials with wrinkled structures exhibit superior advantages of high stretchability and a suitable matrix for photon trapping in between the hill and valley geometries compared to their flat counterparts. Here, the intriguing functionalities of wrinkled reduced graphene oxide, single-layer graphene, and few-layer hexagonal boron nitride, respectively, are utilized to design highly stretchable and wearable random laser devices with ultralow threshold. Using methyl-ammonium lead bromide perovskite nanocrystals (PNC) to illustrate the working principle, the lasing threshold is found to be ≈10 µJ cm -2 , about two times less than the lowest value ever reported. In addition to PNC, it is demonstrated that the output lasing wavelength can be tuned using different active materials such as semiconductor quantum dots. Thus, this study is very useful for the future development of high-performance wearable optoelectronic devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Reexamining the frequency range of hearing in silver (Hypophthalmichthys molitrix) and bighead (H. nobilis) carp

    USGS Publications Warehouse

    Vetter, Brooke J.; Brey, Marybeth; Meninger, Allen F.

    2018-01-01

    Silver (Hypophthalmichthys molitrix) and bighead (H. nobilis) carp (collectively bigheaded carp) are invasive fish that threaten aquatic ecosystems in the upper Midwest United States and the Laurentian Great Lakes. Controlling bigheaded carp is a priority of fisheries managers and one area of focus involves developing acoustic deterrents to prevent upstream migration. For an acoustic deterrent to be effective however, the hearing ability of bigheaded carp must be characterized. A previous study showed that bigheaded carp detected sound up to 3 kHz but this range is narrower than what has been reported for other ostariophysans. Therefore, silver and bighead carp frequency detection was evaluated in response to 100 Hz to 9 kHz using auditory evoked potentials (AEPs). AEPs were recorded from 100 Hz to 5 kHz. The lowest thresholds were at 500 Hz for both species (silver carp threshold: 80.6 ± 3.29 dB re 1 μPa SPLrms, bighead carp threshold: 90.5 ± 5.75 dB re 1 μPa SPLrms; mean ± SD). These results provide fisheries managers with better insight on effective acoustic stimuli for deterrent systems, however, to fully determine bigheaded carp hearing abilities, these results need to be compared with behavioral assessments.

  8. Low threshold lasing of bubble-containing glass microspheres by non-whispering gallery mode excitation over a wide wavelength range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumagai, Tsutaru, E-mail: kumagai.t.af@m.titech.ac.jp; Kishi, Tetsuo; Yano, Tetsuji

    2015-03-21

    Bubble-containing Nd{sup 3+}-doped tellurite glass microspheres were fabricated by localized laser heating technique to investigate their optical properties for use as microresonators. Fluorescence and excitation spectra measurements were performed by pumping with a tunable CW-Ti:Sapphire laser. The excitation spectra manifested several sharp peaks due to the conventional whispering gallery mode (WGM) when the pumping laser was irradiated to the edge part of the microsphere. However, when the excitation light was irradiated on the bubble position inside the microsphere, “non-WGM excitation” was induced, giving rise to numerous peaks at a broad wavelength range in the excitation spectra. Thus, efficient excitation wasmore » achieved over a wide wavelength range. Lasing threshold excited at the bubble position was much lower than that for the excitation at the edges of the microsphere. The lowest value of the laser threshold was 34 μW for a 4 μm sphere containing a 0.5 μm bubble. Efficiency of the excitation at the bubble position with broadband light was calculated to be 5 times higher than that for the edge of the microsphere. The bubble-containing microsphere enables efficient utilization of broadband light excitation from light-emitting diodes and solar light.« less

  9. The firing characteristics of foot sole cutaneous mechanoreceptor afferents in response to vibration stimuli.

    PubMed

    Strzalkowski, Nicholas D J; Ali, R Ayesha; Bent, Leah R

    2017-10-01

    Single unit microneurography was used to record the firing characteristics of the four classes of foot sole cutaneous afferents [fast and slowly adapting type I and II (FAI, FAII, SAI, and SAII)] in response to sinusoidal vibratory stimuli. Frequency (3-250 Hz) and amplitude (0.001-2 mm) combinations were applied to afferent receptive fields through a 6-mm diameter probe. The impulses per cycle, defined as the number of action potentials evoked per vibration sine wave, were measured over 1 s of vibration at each frequency-amplitude combination tested. Afferent entrainment threshold (lowest amplitude at which an afferent could entrain 1:1 to the vibration frequency) and afferent firing threshold (minimum amplitude for which impulses per cycle was greater than zero) were then obtained for each frequency. Increases in vibration frequency are generally associated with decreases in expected impulses per cycle ( P < 0.001), but each foot sole afferent class appears uniquely tuned to vibration stimuli. FAII afferents tended to have the lowest entrainment and firing thresholds ( P < 0.001 for both); however, these afferents seem to be sensitive across frequency. In contrast to FAII afferents, SAI and SAII afferents tended to demonstrate optimal entrainment to frequencies below 20 Hz and FAI afferents faithfully encoded frequencies between 8 and 60 Hz. Contrary to the selective activation of distinct afferent classes in the hand, application of class-specific frequencies in the foot sole is confounded due to the high sensitivity of FAII afferents. These findings may aid in the development of sensorimotor control models or the design of balance enhancement interventions. NEW & NOTEWORTHY Our work provides a mechanistic look at the capacity of foot sole cutaneous afferents to respond to vibration of varying frequency and amplitude. We found that foot sole afferent classes are uniquely tuned to vibration stimuli; however, unlike in the hand, they cannot be independently activated by class-specific frequencies. Viewing the foot sole as a sensory structure, the present findings may aid in the refinement of sensorimotor control models and design of balance enhancement interventions. Copyright © 2017 the American Physiological Society.

  10. Electrophysiological gap detection thresholds: effects of age and comparison with a behavioral measure.

    PubMed

    Palmer, Shannon B; Musiek, Frank E

    2014-01-01

    Temporal processing ability has been linked to speech understanding ability and older adults often complain of difficulty understanding speech in difficult listening situations. Temporal processing can be evaluated using gap detection procedures. There is some research showing that gap detection can be evaluated using an electrophysiological procedure. However, there is currently no research establishing gap detection threshold using the N1-P2 response. The purposes of the current study were to 1) determine gap detection thresholds in younger and older normal-hearing adults using an electrophysiological measure, 2) compare the electrophysiological gap detection threshold and behavioral gap detection threshold within each group, and 3) investigate the effect of age on each gap detection measure. This study utilized an older adult group and younger adult group to compare performance on an electrophysiological and behavioral gap detection procedure. The subjects in this study were 11 younger, normal-hearing adults (mean = 22 yrs) and 11 older, normal-hearing adults (mean = 64.36 yrs). All subjects completed an adaptive behavioral gap detection procedure in order to determine their behavioral gap detection threshold (BGDT). Subjects also completed an electrophysiologic gap detection procedure to determine their electrophysiologic gap detection threshold (EGDT). Older adults demonstrated significantly larger gap detection thresholds than the younger adults. However, EGDT and BGDT were not significantly different in either group. The mean difference between EGDT and BGDT for all subjects was 0.43 msec. Older adults show poorer gap detection ability when compared to younger adults. However, this study shows that gap detection thresholds can be measured using evoked potential recordings and yield results similar to a behavioral measure. American Academy of Audiology.

  11. Comparison of Threshold Detection Methods for the Generalized Pareto Distribution (GPD): Application to the NOAA-NCDC Daily Rainfall Dataset

    NASA Astrophysics Data System (ADS)

    Deidda, Roberto; Mamalakis, Antonis; Langousis, Andreas

    2015-04-01

    One of the most crucial issues in statistical hydrology is the estimation of extreme rainfall from data. To that extent, based on asymptotic arguments from Extreme Excess (EE) theory, several studies have focused on developing new, or improving existing methods to fit a Generalized Pareto Distribution (GPD) model to rainfall excesses above a properly selected threshold u. The latter is generally determined using various approaches that can be grouped into three basic classes: a) non-parametric methods that locate the changing point between extreme and non-extreme regions of the data, b) graphical methods where one studies the dependence of the GPD parameters (or related metrics) to the threshold level u, and c) Goodness of Fit (GoF) metrics that, for a certain level of significance, locate the lowest threshold u that a GPD model is applicable. In this work, we review representative methods for GPD threshold detection, discuss fundamental differences in their theoretical bases, and apply them to daily rainfall records from the NOAA-NCDC open-access database (http://www.ncdc.noaa.gov/oa/climate/ghcn-daily/). We find that non-parametric methods that locate the changing point between extreme and non-extreme regions of the data are generally not reliable, while graphical methods and GoF metrics that rely on limiting arguments for the upper distribution tail lead to unrealistically high thresholds u. The latter is expected, since one checks the validity of the limiting arguments rather than the applicability of a GPD distribution model. Better performance is demonstrated by graphical methods and GoF metrics that rely on GPD properties. Finally, we discuss the effects of data quantization (common in hydrologic applications) on the estimated thresholds. Acknowledgments: The research project is implemented within the framework of the Action «Supporting Postdoctoral Researchers» of the Operational Program "Education and Lifelong Learning" (Action's Beneficiary: General Secretariat for Research and Technology), and is co-financed by the European Social Fund (ESF) and the Greek State.

  12. Spectroscopic study of transparency current in mid-infrared quantum cascade lasers.

    PubMed

    Revin, Dmitry G; Hassan, Randa S; Krysa, Andrey B; Wang, Yongrui; Belyanin, Alexey; Kennedy, Kenneth; Atkins, Chris N; Cockburn, John W

    2012-08-13

    We report measurements which give direct insight into the origins of the transparency current for λ ~5 µm In0.6Ga0.4As/In0.42Al0.58As quantum cascade lasers in the temperature range of 80-280 K. The transparency current values have been found from broadband transmission measurements through the laser waveguides under sub-threshold operating conditions. Two active region designs were compared. The active region of the first laser is based on double-LO-phonon relaxation approach, while the second device has only one lower level, without specially designed resonant LO-phonon assisted depopulation. It is shown that transparency current contributes more than 70% to the magnitude of threshold current at high temperatures for both designs.

  13. Influence of an anomalous dimension effect on thermal instability in amorphous-InGaZnO thin-film transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Kuan-Hsien; Chou, Wu-Ching, E-mail: tcchang3708@gmail.com, E-mail: wuchingchou@mail.nctu.edu.tw; Chang, Ting-Chang, E-mail: tcchang3708@gmail.com, E-mail: wuchingchou@mail.nctu.edu.tw

    2014-10-21

    This paper investigates abnormal dimension-dependent thermal instability in amorphous indium-gallium-zinc-oxide (a-IGZO) thin-film transistors. Device dimension should theoretically have no effects on threshold voltage, except for in short channel devices. Unlike short channel drain-induced source barrier lowering effect, threshold voltage increases with increasing drain voltage. Furthermore, for devices with either a relatively large channel width or a short channel length, the output drain current decreases instead of saturating with an increase in drain voltage. Moreover, the wider the channel and the shorter the channel length, the larger the threshold voltage and output on-state current degradation that is observed. Because of themore » surrounding oxide and other thermal insulating material and the low thermal conductivity of the IGZO layer, the self-heating effect will be pronounced in wider/shorter channel length devices and those with a larger operating drain bias. To further clarify the physical mechanism, fast I{sub D}-V{sub G} and modulated peak/base pulse time I{sub D}-V{sub D} measurements are utilized to demonstrate the self-heating induced anomalous dimension-dependent threshold voltage variation and on-state current degradation.« less

  14. Threshold-voltage modulated phase change heterojunction for application of high density memory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Baihan; Tong, Hao, E-mail: tonghao@hust.edu.cn; Qian, Hang

    2015-09-28

    Phase change random access memory is one of the most important candidates for the next generation non-volatile memory technology. However, the ability to reduce its memory size is compromised by the fundamental limitations inherent in the CMOS technology. While 0T1R configuration without any additional access transistor shows great advantages in improving the storage density, the leakage current and small operation window limit its application in large-scale arrays. In this work, phase change heterojunction based on GeTe and n-Si is fabricated to address those problems. The relationship between threshold voltage and doping concentration is investigated, and energy band diagrams and X-raymore » photoelectron spectroscopy measurements are provided to explain the results. The threshold voltage is modulated to provide a large operational window based on this relationship. The switching performance of the heterojunction is also tested, showing a good reverse characteristic, which could effectively decrease the leakage current. Furthermore, a reliable read-write-erase function is achieved during the tests. Phase change heterojunction is proposed for high-density memory, showing some notable advantages, such as modulated threshold voltage, large operational window, and low leakage current.« less

  15. Single-mode operation of mushroom structure surface emitting lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Y.J.; Dziura, T.G.; Wang, S.C.

    1991-01-01

    Mushroom structure vertical cavity surface emitting lasers with a 0.6 {mu}m GaAs active layer sandwiched by two Al{sub 0.6{sup {minus}}}Ga{sub 0.4}As-Al{sub 0.08}Ga{sub 0.92}As multilayers as top and bottom mirrors exhibit 15 mA pulsed threshold current at 880 nm. Single longitudinal and single transverse mode operation was achieved on lasers with a 5 {mu}m diameter active region at current levels near 2 {times} I{sub th}. The light output above threshold current was linearly polarized with a polarization ratio of 25:1.

  16. High-temperature CW and pulsed operation in constricted double-heterojunction AlGaAs diode lasers

    NASA Technical Reports Server (NTRS)

    Botez, D.; Connolly, J. C.; Gilbert, D. B.

    1981-01-01

    The behavior of constricted double-heterojunction (CDH) diode lasers has been investigated up to 170 C CW and 270 C pulsed. It is found that the temperature-dependent current concentration effect responsible for low threshold-current sensitivity and temperature-invariant external differential quantum efficiency in CDH lasers saturates at about 100 C. It is also found that over a wide temperature interval (180-280 C) the threshold current density has a To value of 40-50 C and that the spontaneous emission becomes increasingly sublinear above 220 C. Both effects are believed to reflect Auger recombination.

  17. Timing discriminator using leading-edge extrapolation

    DOEpatents

    Gottschalk, Bernard

    1983-01-01

    A discriminator circuit to recover timing information from slow-rising pulses by means of an output trailing edge, a fixed time after the starting corner of the input pulse, which is nearly independent of risetime and threshold setting. This apparatus comprises means for comparing pulses with a threshold voltage; a capacitor to be charged at a certain rate when the input signal is one-third threshold voltage, and at a lower rate when the input signal is two-thirds threshold voltage; current-generating means for charging the capacitor; means for comparing voltage capacitor with a bias voltage; a flip-flop to be set when the input pulse reaches threshold voltage and reset when capacitor voltage reaches the bias voltage; and a clamping means for discharging the capacitor when the input signal returns below one-third threshold voltage.

  18. Gain competition in dual wavelength quantum cascade lasers.

    PubMed

    Geiser, Markus; Pflügl, Christian; Belyanin, Alexey; Wang, Qi Jie; Yu, Nanfang; Edamura, Tadanaka; Yamanishi, Masamichi; Kan, Hirofumi; Fischer, Milan; Wittmann, Andreas; Faist, Jérôme; Capasso, Federico

    2010-05-10

    We investigated dual wavelength mid-infrared quantum cascade lasers based on heterogeneous cascades. We found that due to gain competition laser action tends to start in higher order lateral modes. The mid-infrared mode with the lower threshold current reduces population inversion for the second laser with the higher threshold current due to stimulated emission. We developed a rate equation model to quantitatively describe mode interactions due to mutual gain depletion. (c) 2010 Optical Society of America.

  19. Extreme sub-threshold swing in tunnelling relays

    NASA Astrophysics Data System (ADS)

    AbdelGhany, M.; Szkopek, T.

    2014-01-01

    We propose and analyze the theory of the tunnelling relay, a nanoscale active device in which tunnelling current is modulated by electromechanical actuation of a suspended membrane above a fixed electrode. The tunnelling current is modulated exponentially with vacuum gap length, permitting an extreme sub-threshold swing of ˜10 mV/decade breaking the thermionic limit. The predicted performance suggests that a significant reduction in dynamic energy consumption over conventional field effect transistors is physically achievable.

  20. Effect of thermal insulation on the electrical characteristics of NbOx threshold switches

    NASA Astrophysics Data System (ADS)

    Wang, Ziwen; Kumar, Suhas; Wong, H.-S. Philip; Nishi, Yoshio

    2018-02-01

    Threshold switches based on niobium oxide (NbOx) are promising candidates as bidirectional selector devices in crossbar memory arrays and building blocks for neuromorphic computing. Here, it is experimentally demonstrated that the electrical characteristics of NbOx threshold switches can be tuned by engineering the thermal insulation. Increasing the thermal insulation by ˜10× is shown to produce ˜7× reduction in threshold current and ˜45% reduction in threshold voltage. The reduced threshold voltage leads to ˜5× reduction in half-selection leakage, which highlights the effectiveness of reducing half-selection leakage of NbOx selectors by engineering the thermal insulation. A thermal feedback model based on Poole-Frenkel conduction in NbOx can explain the experimental results very well, which also serves as a piece of strong evidence supporting the validity of the Poole-Frenkel based mechanism in NbOx threshold switches.

  1. Safety parameter considerations of anodal transcranial Direct Current Stimulation in rats.

    PubMed

    Jackson, Mark P; Truong, Dennis; Brownlow, Milene L; Wagner, Jessica A; McKinley, R Andy; Bikson, Marom; Jankord, Ryan

    2017-08-01

    A commonly referenced transcranial Direct Current Stimulation (tDCS) safety threshold derives from tDCS lesion studies in the rat and relies on electrode current density (and related electrode charge density) to support clinical guidelines. Concerns about the role of polarity (e.g. anodal tDCS), sub-lesion threshold injury (e.g. neuroinflammatory processes), and role of electrode montage across rodent and human studies support further investigation into animal models of tDCS safety. Thirty-two anesthetized rats received anodal tDCS between 0 and 5mA for 60min through one of three epicranial electrode montages. Tissue damage was evaluated using hemotoxylin and eosin (H&E) staining, Iba-1 immunohistochemistry, and computational brain current density modeling. Brain lesion occurred after anodal tDCS at and above 0.5mA using a 25.0mm 2 electrode (electrode current density: 20.0A/m 2 ). Lesion initially occurred using smaller 10.6mm 2 or 5.3mm 2 electrodes at 0.25mA (23.5A/m 2 ) and 0.5mA (94.2A/m 2 ), respectively. Histological damage was correlated with computational brain current density predictions. Changes in microglial phenotype occurred in higher stimulation groups. Lesions were observed using anodal tDCS at an electrode current density of 20.0A/m 2 , which is below the previously reported safety threshold of 142.9A/m 2 using cathodal tDCS. The lesion area is not simply predicted by electrode current density (and so not by charge density as duration was fixed); rather computational modeling suggests average brain current density as a better predictor for anodal tDCS. Nonetheless, under the assumption that rodent epicranial stimulation is a hypersensitive model, an electrode current density of 20.0A/m 2 represents a conservative threshold for clinical tDCS, which typically uses an electrode current density of 2A/m 2 when electrodes are placed on the skin (resulting in a lower brain current density). Copyright © 2017 Elsevier Inc. All rights reserved.

  2. PEDOT-CNT coated electrodes stimulate retinal neurons at low voltage amplitudes and low charge densities

    NASA Astrophysics Data System (ADS)

    Samba, R.; Herrmann, T.; Zeck, G.

    2015-02-01

    Objective. The aim of this study was to compare two different microelectrode materials—the conductive polymer composite poly-3,4-ethylenedioxythiophene (PEDOT)-carbon nanotube(CNT) and titanium nitride (TiN)—at activating spikes in retinal ganglion cells in whole mount rat retina through stimulation of the local retinal network. Stimulation efficacy of the microelectrodes was analyzed by comparing voltage, current and transferred charge at stimulation threshold. Approach. Retinal ganglion cell spikes were recorded by a central electrode (30 μm diameter) in the planar grid of an electrode array. Extracellular stimulation (monophasic, cathodic, 0.1-1.0 ms) of the retinal network was performed using constant voltage pulses applied to the eight surrounding electrodes. The stimulation electrodes were equally spaced on the four sides of a square (400 × 400 μm). Threshold voltage was determined as the pulse amplitude required to evoke network-mediated ganglion cell spiking in a defined post stimulus time window in 50% of identical stimulus repetitions. For the two electrode materials threshold voltage, transferred charge at threshold, maximum current and the residual current at the end of the pulse were compared. Main results. Stimulation of retinal interneurons using PEDOT-CNT electrodes is achieved with lower stimulation voltage and requires lower charge transfer as compared to TiN. The key parameter for effective stimulation is a constant current over at least 0.5 ms, which is obtained by PEDOT-CNT electrodes at lower stimulation voltage due to its faradaic charge transfer mechanism. Significance. In neuroprosthetic implants, PEDOT-CNT may allow for smaller electrodes, effective stimulation in a safe voltage regime and lower energy-consumption. Our study also indicates, that the charge transferred at threshold or the charge injection capacity per se does not determine stimulation efficacy.

  3. Role of the Excitability Brake Potassium Current IKD in Cold Allodynia Induced by Chronic Peripheral Nerve Injury.

    PubMed

    González, Alejandro; Ugarte, Gonzalo; Restrepo, Carlos; Herrera, Gaspar; Piña, Ricardo; Gómez-Sánchez, José Antonio; Pertusa, María; Orio, Patricio; Madrid, Rodolfo

    2017-03-22

    Cold allodynia is a common symptom of neuropathic and inflammatory pain following peripheral nerve injury. The mechanisms underlying this disabling sensory alteration are not entirely understood. In primary somatosensory neurons, cold sensitivity is mainly determined by a functional counterbalance between cold-activated TRPM8 channels and Shaker-like Kv1.1-1.2 channels underlying the excitability brake current I KD Here we studied the role of I KD in damage-triggered painful hypersensitivity to innocuous cold. We found that cold allodynia induced by chronic constriction injury (CCI) of the sciatic nerve in mice, was related to both an increase in the proportion of cold-sensitive neurons (CSNs) in DRGs contributing to the sciatic nerve, and a decrease in their cold temperature threshold. I KD density was reduced in high-threshold CSNs from CCI mice compared with sham animals, with no differences in cold-induced TRPM8-dependent current density. The electrophysiological properties and neurochemical profile of CSNs revealed an increase of nociceptive-like phenotype among neurons from CCI animals compared with sham mice. These results were validated using a mathematical model of CSNs, including I KD and TRPM8, showing that a reduction in I KD current density shifts the thermal threshold to higher temperatures and that the reduction of this current induces cold sensitivity in former cold-insensitive neurons expressing low levels of TRPM8-like current. Together, our results suggest that cold allodynia is largely due to a functional downregulation of I KD in both high-threshold CSNs and in a subpopulation of polymodal nociceptors expressing TRPM8, providing a general molecular and neural mechanism for this sensory alteration. SIGNIFICANCE STATEMENT This paper unveils the critical role of the brake potassium current I KD in damage-triggered cold allodynia. Using a well-known form of nerve injury and combining behavioral analysis, calcium imaging, patch clamping, and pharmacological tools, validated by mathematical modeling, we determined that the functional expression of I KD is reduced in sensory neurons in response to peripheral nerve damage. This downregulation not only enhances cold sensitivity of high-threshold cold thermoreceptors signaling cold discomfort, but it also transforms a subpopulation of polymodal nociceptors signaling pain into neurons activated by mild temperature drops. Our results suggest that cold allodynia is linked to a reduction of I KD in both high-threshold cold thermoreceptors and nociceptors expressing TRPM8, providing a general model for this form of cold-induced pain. Copyright © 2017 the authors 0270-6474/17/373109-18$15.00/0.

  4. Pharmacological and anatomical separation of calcium currents in rat dentate granule neurones in vitro.

    PubMed Central

    Blaxter, T J; Carlen, P L; Niesen, C

    1989-01-01

    1. Rat dentate granule neurones in hippocampal slices were voltage-clamped at 21-23 degrees C using CsCl-filled microelectrodes. The perfusate contained TTX and K+ channel blockers to isolate pharmacologically inward Ca2+ currents. 2. From hyperpolarized holding potentials of -65 to -85 mV, depolarizing test potentials to between -50 and -40 mV elicited a transient (100-200 ms) low-threshold (TLT) current which was also elicited from more depolarized holding potentials following hyperpolarizing voltage steps of -40 mV or greater. 3. Larger depolarizing steps from a hyperpolarized holding potential triggered a large (2-6 nA), transient high-threshold (THT) inward current, rapidly peaking and decaying over 500 ms, followed by a sustained inward current component. 4. At depolarized holding potentials (-50 to -20 mV), the THT current was apparently inactivated and a sustained high-threshold (SHT) inward current was evident during depolarizing voltage steps of 10 mV or more. 5. From hyperpolarized holding potentials with depolarizing voltage steps of 10-30 mV, most neurones demonstrated a small-amplitude, sustained low-threshold (SLT) inward current with similar characteristics to the SHT current. 6. Zero-Ca2+ perfusate or high concentrations of Ca2+ channel blockers (Cd2+, Mn2+ or Ni2+) diminished or abolished all inward currents. 7. Repetitive voltage step activation of each current at 0.5 Hz reduced the large THT current to less than 25% of an unconditioned control current, reduced the SHT current by 50%, but had little effect on the TLT current. 8. A low concentration of Cd2+ (50 microM) blocked the THT and SHT currents with little effect on the TLT current. Nimodipine (1 microM) attenuated the SHT current. Ni2+ (100 microM) selectively attenuated the TLT current. 9. In low-Ca2+ perfusate, high concentrations of Ca2+ (10-15 mM), focally applied to different parts of the neurone, increased the THT current when applied to the dendrites, the SHT current when applied to the soma and the TLT current at all locations. Conversely, in regular perfusate, Cd2+ (1-5 mM), focally applied to the dendrites decreased the THT current and somatic applications decreased the SHT current. The TLT current was diminished regardless of the site of Cd2+ application. 10. These results suggest the existence of three different Ca2+ currents in dentate granule cells separable by their activation and inactivation characteristics, pharmacology and site of initiation. PMID:2557433

  5. Comparison of two insulin assays for first-phase insulin release in type 1 diabetes prediction and prevention studies

    PubMed Central

    Mahon, Jeffrey L.; Beam, Craig A.; Marcovina, Santica M.; Boulware, David C.; Palmer, Jerry P.; Winter, William E.; Skyler, Jay S.; Krischer, Jeffrey P.

    2018-01-01

    Background Detection of below-threshold first-phase insulin release or FPIR (1 + 3 minute insulin concentrations during an intravenous glucose tolerance test [IVGTT]) is important in type 1 diabetes prediction and prevention studies including the TrialNet Oral Insulin Prevention Trial. We assessed whether an insulin immunoenzymometric assay (IEMA) could replace the less practical but current standard of a radioimmunoassay (RIA) for FPIR. Methods One hundred thirty-three islet autoantibody positive relatives of persons with type 1 diabetes underwent 161 IVGTTs. Insulin concentrations were measured by both assays in 1056 paired samples. A rule classifying FPIR (below-threshold, above-threshold, uncertain) by the IEMA was derived and validated against FPIR by the RIA. Results The insulin IEMA-based rule accurately classified below- and above-threshold FPIRs by the RIA in 110/161 (68%) IVGTTs, but was uncertain in 51/161 (32%) tests for which FPIR by RIA is needed. An uncertain FPIR by the IEMA was more likely among below-threshold vs above-threshold FPIRs by the RIA (64% [30/47] vs. 18% [21/114], respectively; p < 0.05). Conclusions An insulin IEMA for FPIR in subjects at risk for type 1 diabetes accurately determined below- and above-threshold FPIRs in 2/3 of tests relative to the current standard of the insulin RIA, but could not reliably classify the remaining FPIRs. TrialNet is limiting the insulin RIA for FPIR to the latter given the practical advantages of the more specific IEMA. PMID:21843518

  6. Competitive photodissociation channels in jet-cooled HNCO: Thermochemistry and near-threshold predissociation

    NASA Astrophysics Data System (ADS)

    Zyrianov, M.; Droz-Georget, Th.; Sanov, A.; Reisler, H.

    1996-11-01

    The photoinitiated unimolecular decomposition of jet-cooled HNCO has been studied following S1(1A″)←S0(1A') excitation near the thresholds of the spin-allowed dissociation channels: (1) H(2S)+NCO(X2Π) and (2) NH(a1Δ)+CO(X1Σ+), which are separated by 4470 cm-1. Photofragment yield spectra of NCO(X2Π) and NH (a1Δ) were obtained in selected regions in the 260-220 nm photolysis range. The NCO(X2Π)yield rises abruptly at 38 380 cm-1 and the spectrum exhibits structures as narrow as 0.8 cm-1 near the threshold. The linewidths increase only slowly with photolysis energy. The jet-cooled absorption spectrum near the channel (1) threshold [D0(H+NCO)] was obtained using two-photon excitation via the S1 state, terminating in a fluorescent product. The absorption spectrum is similar to the NCO yield spectrum, and its intensity does not diminish noticeably above D0(H+NCO), indicating that dissociation near threshold is slow. The NCO product near threshold is cold, as is typical of a barrierless reaction. NH (a1Δ) products appear first at 42 840 cm-1, but their yield is initially very small, as evidenced also by the insignificant decrease in the NCO yield in the threshold region of channel (2). The NH (a1Δ) yield increases faster at higher photolysis energies and the linewidths increase as well. At the channel (2) threshold, the NH (a1Δ) product is generated only in the lowest rotational level, J=2, and rotational excitation increases with photolysis energy. We propose that in the range 260-230 nm, HNCO (S1) undergoes radiationless decay terminating in S0/T1 followed by unimolecular reaction. Decompositions via channels (1) and (2) proceed without significant exit channel barriers. At wavelengths shorter than 230 nm, the participation of an additional, direct pathway cannot be ruled out. The jet-cooled photofragment yield spectra allow the determination, with good accuracy, of thermochemical values relevant to HNCO decomposition. The following heats of formation are recommended: ΔH0f(HNCO)=-27.8±0.4 kcal/mol, and ΔH0f(NCO)=30.3±0.4 kcal/mol. These results are in excellent agreement with recent determinations using different experimental techniques.

  7. Effect of Pulse Polarity on Thresholds and on Non-monotonic Loudness Growth in Cochlear Implant Users.

    PubMed

    Macherey, Olivier; Carlyon, Robert P; Chatron, Jacques; Roman, Stéphane

    2017-06-01

    Most cochlear implants (CIs) activate their electrodes non-simultaneously in order to eliminate electrical field interactions. However, the membrane of auditory nerve fibers needs time to return to its resting state, causing the probability of firing to a pulse to be affected by previous pulses. Here, we provide new evidence on the effect of pulse polarity and current level on these interactions. In experiment 1, detection thresholds and most comfortable levels (MCLs) were measured in CI users for 100-Hz pulse trains consisting of two consecutive biphasic pulses of the same or of opposite polarity. All combinations of polarities were studied: anodic-cathodic-anodic-cathodic (ACAC), CACA, ACCA, and CAAC. Thresholds were lower when the adjacent phases of the two pulses had the same polarity (ACCA and CAAC) than when they were different (ACAC and CACA). Some subjects showed a lower threshold for ACCA than for CAAC while others showed the opposite trend demonstrating that polarity sensitivity at threshold is genuine and subject- or electrode-dependent. In contrast, anodic (CAAC) pulses always showed a lower MCL than cathodic (ACCA) pulses, confirming previous reports. In experiments 2 and 3, the subjects compared the loudness of several pulse trains differing in current level separately for ACCA and CAAC. For 40 % of the electrodes tested, loudness grew non-monotonically as a function of current level for ACCA but never for CAAC. This finding may relate to a conduction block of the action potentials along the fibers induced by a strong hyperpolarization of their central processes. Further analysis showed that the electrodes showing a lower threshold for ACCA than for CAAC were more likely to yield a non-monotonic loudness growth. It is proposed that polarity sensitivity at threshold reflects the local neural health and that anodic asymmetric pulses should preferably be used to convey sound information while avoiding abnormal loudness percepts.

  8. Spacer engineered Trigate SOI TFET: An investigation towards harsh temperature environment applications

    NASA Astrophysics Data System (ADS)

    Mallikarjunarao; Ranjan, Rajeev; Pradhan, K. P.; Artola, L.; Sahu, P. K.

    2016-09-01

    In this paper, a novel N-channel Tunnel Field Effect Transistor (TFET) i.e., Trigate Silicon-ON-Insulator (SOI) N-TFET with high-k spacer is proposed for better Sub-threshold swing (SS) and OFF-state current (IOFF) by keeping in mind the sensitivity towards temperature. The proposed model can achieve a Sub-threshold swing less than 35 mV/decade at various temperatures, which is desirable for designing low power CTFET for digital circuit applications. In N-TFET source doping has a significant effect on the ON-state current (ION) level; therefore more electrons will tunnel from source to channel region. High-k Spacer i.e., HfO2 is used to enhance the device performance and also it avoids overlapping of transistors in an integrated circuits (IC's). We have designed a reliable device by performing the temperature analysis on Transfer characteristics, Drain characteristics and also on various performance metrics like ON-state current (ION), OFF-state current (IOFF), ION/IOFF, Trans-conductance (gm), Trans-conductance Generation Factor (TGF), Sub-threshold Swing (SS) to observe the applications towards harsh temperature environment.

  9. Voluntary Running-Wheel Exercise Decreases the Threshold for Rewarding Intracranial Self-Stimulation

    PubMed Central

    Morris, Michael J.; Na, Elisa S.; Johnson, Alan Kim

    2015-01-01

    Physical exercise has mood-enhancing and antidepressant properties although the mechanisms underlying these effects are not known. The present experiment investigated the effects of prolonged access to a running wheel on electrical self-stimulation of the lateral hypothalamus (LHSS), a measure of hedonic state, in rats. Rats with continuous voluntary access to a running wheel for either 2 or 5 weeks exhibited dramatic leftward shifts in the effective current 50 (ECu50; current value that supports half of maximum responding) of their LHSS current-response functions compared to their baselines, indicating a decrease in reward threshold, whereas control rats current-response functions after 2 or 5 weeks were not significantly different from baseline. An inverse correlation existed between the change in ECu50 from baseline and the amount an animal had run in the day prior to LHSS testing, indicating that animals that exhibited higher levels of running showed a more robust decrease in LHSS threshold. We conclude that long-term voluntary exercise increases sensitivity to rewarding stimuli, which may contribute to its antidepressant properties. PMID:22845707

  10. Voluntary running-wheel exercise decreases the threshold for rewarding intracranial self-stimulation.

    PubMed

    Morris, Michael J; Na, Elisa S; Johnson, Alan Kim

    2012-08-01

    Physical exercise has mood-enhancing and antidepressant properties although the mechanisms underlying these effects are not known. The present experiment investigated the effects of prolonged access to a running wheel on electrical self-stimulation of the lateral hypothalamus (LHSS), a measure of hedonic state, in rats. Rats with continuous voluntary access to a running wheel for either 2 or 5 weeks exhibited dramatic leftward shifts in the effective current 50 (ECu50; current value that supports half of maximum responding) of their LHSS current-response functions compared to their baselines, indicating a decrease in reward threshold, whereas control rats current-response functions after 2 or 5 weeks were not significantly different from baseline. An inverse correlation existed between the change in ECu50 from baseline and the amount an animal had run in the day prior to LHSS testing, indicating that animals that exhibited higher levels of running showed a more robust decrease in LHSS threshold. We conclude that long-term voluntary exercise increases sensitivity to rewarding stimuli, which may contribute to its antidepressant properties.

  11. Socially disparate trends in lifespan variation: a trend study on income and mortality based on nationwide Danish register data.

    PubMed

    Brønnum-Hansen, Henrik

    2017-05-17

    Social inequality trends in life expectancy are not informative as to changes in social disparity in the age-at-death distribution. The purpose of the study was to investigate social differentials in trends and patterns of adult mortality in Denmark. Register data on income and mortality from 1986 to 2014 were used to investigate trends in life expectancy, life disparity and the threshold age that separates 'premature' and 'late' deaths. Mortality compression was quantified and compared between income quartiles. Since 1986, male life expectancy increased by 4.2 years for the lowest income quartile and by 8.4 years for the highest income quartile. The clear compression of mortality apparent in the highest income quartile did not occur for the lowest income quartile. Premature and late deaths accounted both by 2.1 years of the increase in life expectancy in the lowest income quartile and by 6.0 and 2.4 years, respectively, in the highest income quartile. Life expectancy increased by 5.2 years among women in the lowest income quartile, 2.4 years due to premature deaths and 2.8 years due to late deaths. The gain in life expectancy among women in the highest income quartile of 5.6 years was distributed by 5.0 and 0.6 years due to premature and late deaths, respectively. The study demonstrates that the increasing social gap in mortality appears differently in the change of the age-at-death distribution. Thus, no compression of mortality was seen in the lowest income quartile. The results do not provide support for a uniformly extension of pension age for all. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Lead exposure potentiates predatory attack behavior in the cat.

    PubMed

    Li, Wenjie; Han, Shenggao; Gregg, Thomas R; Kemp, Francis W; Davidow, Amy L; Louria, Donald B; Siegel, Allan; Bogden, John D

    2003-07-01

    Epidemiologic studies have demonstrated that environmental lead exposure is associated with aggressive behavior in children; however, numerous confounding variables limit the ability of these studies to establish a causal relationship. The study of aggressive behavior using a validated animal model was used to test the hypothesis that there is a causal relationship between lead exposure and aggression in the absence of confounding variables. We studied the effects of lead exposure on a feline model of aggression: predatory (quiet biting) attack of an anesthetized rat. Five cats were stimulated with a precisely controlled electrical current via electrodes inserted into the lateral hypothalamus. The response measure was the predatory attack threshold current (i.e., the current required to elicit an attack response on 50% of the trials). Blocks of trials were administered in which predatory attack threshold currents were measured three times a week for a total of 6-10 weeks, including before, during, and after lead exposure. Lead was incorporated into cat food "treats" at doses of 50-150 mg/kg/day. Two of the five cats received a second period of lead exposure. Blood lead concentrations were measured twice a week and were <1, 21-77, and <20 micro g/dL prior to, during, and after lead exposure, respectively. The predatory attack threshold decreased significantly during initial lead exposure in three of five cats and increased after the cessation of lead exposure in four of the five cats (P<0.01). The predatory attack thresholds and blood lead concentrations for each cat were inversely correlated (r=-0.35 to -0.74). A random-effects mixed model demonstrated a significant (P=0.0019) negative association between threshold current and blood lead concentration. The data of this study demonstrate that lead exposure enhances predatory aggression in the cat and provide experimental support for a causal relationship between lead exposure and aggressive behavior in humans.

  13. Low-threshold field emission in planar cathodes with nanocarbon materials

    NASA Astrophysics Data System (ADS)

    Zhigalov, V.; Petukhov, V.; Emelianov, A.; Timoshenkov, V.; Chaplygin, Yu.; Pavlov, A.; Shamanaev, A.

    2016-12-01

    Nanocarbon materials are of great interest as field emission cathodes due to their low threshold voltage. In this work current-voltage characteristics of nanocarbon electrodes were studied. Low-threshold emission was found in planar samples where field enhancement is negligible (<10). Electron work function values, calculated by Fowler-Nordheim theory, are anomalous low (<1 eV) and come into collision with directly measured work function values in fabricated planar samples (4.1-4.4 eV). Non-applicability of Fowler-Nordheim theory for the nanocarbon materials was confirmed. The reasons of low-threshold emission in nanocarbon materials are discussed.

  14. Higgs boson gluon-fusion production beyond threshold in N 3LO QCD

    DOE PAGES

    Anastasiou, Charalampos; Duhr, Claude; Dulat, Falko; ...

    2015-03-18

    In this study, we compute the gluon fusion Higgs boson cross-section at N 3LO through the second term in the threshold expansion. This calculation constitutes a major milestone towards the full N 3LO cross section. Our result has the best formal accuracy in the threshold expansion currently available, and includes contributions from collinear regions besides subleading corrections from soft and hard regions, as well as certain logarithmically enhanced contributions for general kinematics. We use our results to perform a critical appraisal of the validity of the threshold approximation at N 3LO in perturbative QCD.

  15. Eccentric figure-eight coils for transcranial magnetic stimulation.

    PubMed

    Sekino, Masaki; Ohsaki, Hiroyuki; Takiyama, Yoshihiro; Yamamoto, Keita; Matsuzaki, Taiga; Yasumuro, Yoshihiro; Nishikawa, Atsushi; Maruo, Tomoyuki; Hosomi, Koichi; Saitoh, Youichi

    2015-01-01

    Previously we proposed an eccentric figure-eight coil that can cause threshold stimulation in the brain at lower driving currents. In this study, we performed numerical simulations and magnetic stimulations to healthy subjects for evaluating the advantages of the eccentric coil. The simulations were performed using a simplified spherical brain model and a realistic human brain model. We found that the eccentric coil required a driving current intensity of approximately 18% less than that required by the concentric coil to cause comparable eddy current densities within the brain. The eddy current localization of the eccentric coil was slightly higher than that of the concentric coil. A prototype eccentric coil was designed and fabricated. Instead of winding a wire around a bobbin, we cut eccentric-spiral slits on the insulator cases, and a wire was woven through the slits. The coils were used to deliver magnetic stimulation to healthy subjects; among our results, we found that the current slew rate corresponding to motor threshold values for the concentric and eccentric coils were 86 and 78 A/µs, respectively. The results indicate that the eccentric coil consistently requires a lower driving current to reach the motor threshold than the concentric coil. Future development of compact magnetic stimulators will enable the treatment of some intractable neurological diseases at home. © 2014 Wiley Periodicals, Inc.

  16. Minimum Electric Field Exposure for Seizure Induction with Electroconvulsive Therapy and Magnetic Seizure Therapy.

    PubMed

    Lee, Won H; Lisanby, Sarah H; Laine, Andrew F; Peterchev, Angel V

    2017-05-01

    Lowering and individualizing the current amplitude in electroconvulsive therapy (ECT) has been proposed as a means to produce stimulation closer to the neural activation threshold and more focal seizure induction, which could potentially reduce cognitive side effects. However, the effect of current amplitude on the electric field (E-field) in the brain has not been previously linked to the current amplitude threshold for seizure induction. We coupled MRI-based E-field models with amplitude titrations of motor threshold (MT) and seizure threshold (ST) in four nonhuman primates (NHPs) to determine the strength, distribution, and focality of stimulation in the brain for four ECT electrode configurations (bilateral, bifrontal, right-unilateral, and frontomedial) and magnetic seizure therapy (MST) with cap coil on vertex. At the amplitude-titrated ST, the stimulated brain subvolume (23-63%) was significantly less than for conventional ECT with high, fixed current (94-99%). The focality of amplitude-titrated right-unilateral ECT (25%) was comparable to cap coil MST (23%), demonstrating that ECT with a low current amplitude and focal electrode placement can induce seizures with E-field as focal as MST, although these electrode and coil configurations affect differently specific brain regions. Individualizing the current amplitude reduced interindividual variation in the stimulation focality by 40-53% for ECT and 26% for MST, supporting amplitude individualization as a means of dosing especially for ECT. There was an overall significant correlation between the measured amplitude-titrated ST and the prediction of the E-field models, supporting a potential role of these models in dosing of ECT and MST. These findings may guide the development of seizure therapy dosing paradigms with improved risk/benefit ratio.

  17. Properties of the low threshold Ca current in single frog atrial cardiomyocytes. A comparison with the high threshold Ca current

    PubMed Central

    1992-01-01

    The properties of the low threshold Ca current (ICaT) in bullfrog (Rana catesbeiana) isolated atrial cardiomyocytes were studied using the whole-cell recording patch-clamp technique and compared with those of the high threshold Ca current (ICaL). In 91% of atrial cells we observed both ICaT and ICaL when collagenase and trypsin were used to dissociate the cells. But when pronase was used, only 30% of the cells exhibited ICaT. ICaT was never found in ventricular cells. ICaT could be investigated more easily when ICaL was inhibited by Cd ions (50 microM). Its kinetics were unchanged by substituting Ba for Ca, or in the presence of high concentrations of Ba. Both ICaT and ICaL exhibited reduced inactivation after high depolarizing prepulses. ICaT was found to be sensitive to dihydropyridines: 1 microM nifedipine decreased this current while 1 microM BAY K 8644 increased it; this occurred without significant variations in the steady-state inactivation curve. ICaT was more sensitive than ICaL to alpha 1-adrenergic and P2-purinergic stimulations, while ICaL was more sensitive to beta-adrenergic stimulation. Isoproterenol was still able to increase ICaT in the presence of high intracellular cAMP. Both currents were increased by 1 microM ouabain (although ICaL only transiently) and decreased by 10 microM ouabain. It is concluded that the two types of Ca channels can be observed in bullfrog atrial cells and that they are specifically altered by pharmacological agents and neuromediators. This may have implications for cardiac behavior. PMID:1279097

  18. Muscle Activation During Peripheral Nerve Field Stimulation Occurs Due to Recruitment of Efferent Nerve Fibers, Not Direct Muscle Activation.

    PubMed

    Frahm, Ken Steffen; Hennings, Kristian; Vera-Portocarrero, Louis; Wacnik, Paul W; Mørch, Carsten Dahl

    2016-08-01

    Peripheral nerve field stimulation (PNFS) is a potential treatment for chronic low-back pain. Pain relief using PNFS is dependent on activation of non-nociceptive Aβ-fibers. However, PNFS may also activate muscles, causing twitches and discomfort. In this study, we developed a mathematical model, to investigate the activation of sensory and motor nerves, as well as direct muscle fiber activation. The extracellular field was estimated using a finite element model based on the geometry of CT scanned lumbar vertebrae. The electrode was modeled as being implanted to a depth of 10-15 mm. Three implant directions were modeled; horizontally, vertically, and diagonally. Both single electrode and "between-lead" stimulation between contralateral electrodes were modeled. The extracellular field was combined with models of sensory Aβ-nerves, motor neurons and muscle fibers to estimate their activation thresholds. The model showed that sensory Aβ fibers could be activated with thresholds down to 0.563 V, and the lowest threshold for motor nerve activation was 7.19 V using between-lead stimulation with the cathode located closest to the nerves. All thresholds for direct muscle activation were above 500 V. The results suggest that direct muscle activation does not occur during PNFS, and concomitant motor and sensory nerve fiber activation are only likely to occur when using between-lead configuration. Thus, it may be relevant to investigate the location of the innervation zone of the low-back muscles prior to electrode implantation to avoid muscle activation. © 2016 International Neuromodulation Society.

  19. Financial catastrophe and poverty impacts of out-of-pocket health payments in Turkey.

    PubMed

    Özgen Narcı, Hacer; Şahin, İsmet; Yıldırım, Hasan Hüseyin

    2015-04-01

    To determine the prevalence of catastrophic health payments, examine the determinants of catastrophic expenditures, and assess the poverty impact of out-of-pocket (OOP) payments. Data came from the 2004 to 2010 Household Budget Survey. Catastrophic health spending was defined by health payments as percentage of household consumption expenditures and capacity to pay at a set of thresholds. The poverty impact was evaluated by poverty head counts and poverty gaps before and after OOP health payments. The percentage of households that catastrophically spent their consumption expenditure and capacity to pay increased from 2004 to 2010, regardless of the threshold used. Households with a share of more than 40% health spending in both consumption expenditure and capacity to pay accounted for less than 1% across years. However, when a series of potential confounders were taken into account, the study found statistically significantly increased risk for the lowest threshold and decreased risk for the highest threshold in 2010 relative to the base year. Household income, size, education, senior and under 5-year-old members, health insurance, disabled members, payment for inpatient care and settlement were also statistically significant predictors of catastrophic health spending. Overall, poverty head counts were below 1%. Poverty gaps reached a maximum of 0.098%, with an overall increase in 2010 compared to 2004. Catastrophe and poverty increased from 2004 to 2010. However, given that the realization of some recent policies will affect the financial burden of OOP payments on households, the findings of this study need to be replicated.

  20. CSF lactate alone is not a reliable indicator of bacterial ventriculitis in patients with ventriculostomies.

    PubMed

    Hill, Emily; Bleck, Thomas P; Singh, Kamaljit; Ouyang, Bichun; Busl, Katharina M

    2017-06-01

    In a febrile patient with a ventriculostomy, diagnosing or excluding bacterial or microbial ventriculitis is difficult, as conventional markers in analysis of cerebrospinal fluid (CSF) are not applicable due to presence of blood and inflammation. CSF lactate has been shown to be a useful indicator of bacterial meningitis in CSF obtained via lumbar puncture, but little and heterogenous data exist on patients with ventriculostomies. We reviewed all CSF analyses obtained via ventriculostomy in patients admitted to our tertiary medical center between 2008 and 2013, and constructed receiver operating characteristic (ROC) curves to evaluate the accuracy of CSF lactate concentration in discriminating a positive CSF culture from a negative one in setting of ventriculostomy and prophylactic antibiosis. Among 467 CSF lactate values, there were 22 corresponding CSF cultures with bacterial growth. Sensitivities and specificities for CSF lactate at threshold values 3, 4, 5 and 6mmol/L showed sensitivity and specificity greater than 70% for CSF lactate threshold 4mmol/L. The lowest threshold value of 3mmol/L resulted in higher sensitivity of 81.8%, and the highest chosen threshold value resulted in high specificity of 94.2%, but these values had poor corresponding specificity and sensitivity, respectively. The area under the curve was 0.82 (95% CI 0.72, 0.91). Our data from a large sample of CSF studies in patients with ventriculostomy indicate that no single value of CSF lactate provided both sensitivity and specificity high enough to be regarded as reliable test. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A Near-Threshold Shape Resonance in the Valence-Shell Photoabsorption of Linear Alkynes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacovella, U.; Holland, D. M. P.; Boyé-Péronne, S.

    2015-12-17

    The room-temperature photoabsorption spectra of a number of linear alkynes with internal triple bonds (e.g., 2-butyne, 2-pentyne, and 2- and 3-hexyne) show similar resonances just above the lowest ionization threshold of the neutral molecules. These features result in a substantial enhancement of the photoabsorption cross sections relative to the cross sections of alkynes with terminal triple bonds (e.g., propyne, 1-butyne, 1-pentyne,...). Based on earlier work on 2-butyne [Xu et al., J. Chem. Phys. 2012, 136, 154303], these features are assigned to excitation from the neutral highest occupied molecular orbital (HOMO) to a shape resonance with g (l = 4) charactermore » and approximate pi symmetry. This generic behavior results from the similarity of the HOMOs in all internal alkynes, as well as the similarity of the corresponding g pi virtual orbital in the continuum. Theoretical calculations of the absorption spectrum above the ionization threshold for the 2- and 3-alkynes show the presence of a shape resonance when the coupling between the two degenerate or nearly degenerate pi channels is included, with a dominant contribution from l = 4. These calculations thus confirm the qualitative arguments for the importance of the l = 4 continuum near threshold for internal alkynes, which should also apply to other linear internal alkynes and alkynyl radicals. The 1-alkynes do not have such high partial waves present in the shape resonance. The lower l partial waves in these systems are consistent with the broader features observed in the corresponding spectra.« less

  2. Health hazards of ultrafine metal and metal oxide powders

    NASA Technical Reports Server (NTRS)

    Boylen, G. W., Jr.; Chamberlin, R. I.; Viles, F. J.

    1969-01-01

    Study reveals that suggested threshold limit values are from two to fifty times lower than current recommended threshold limit values. Proposed safe limits of exposure to the ultrafine dusts are based on known toxic potential of various materials as determined in particle size ranges.

  3. Ultrasonically triggered ignition at liquid surfaces.

    PubMed

    Simon, Lars Hendrik; Meyer, Lennart; Wilkens, Volker; Beyer, Michael

    2015-01-01

    Ultrasound is considered to be an ignition source according to international standards, setting a threshold value of 1mW/mm(2) [1] which is based on theoretical estimations but which lacks experimental verification. Therefore, it is assumed that this threshold includes a large safety margin. At the same time, ultrasound is used in a variety of industrial applications where it can come into contact with explosive atmospheres. However, until now, no explosion accidents have been reported in connection with ultrasound, so it has been unclear if the current threshold value is reasonable. Within this paper, it is shown that focused ultrasound coupled into a liquid can in fact ignite explosive atmospheres if a specific target positioned at a liquid's surface converts the acoustic energy into a hot spot. Based on ignition tests, conditions could be derived that are necessary for an ultrasonically triggered explosion. These conditions show that the current threshold value can be significantly augmented. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Improved Controller Design of Grid Friendly™ Appliances for Primary Frequency Response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lian, Jianming; Sun, Yannan; Marinovici, Laurentiu D.

    2015-09-01

    The Grid Friendlymore » $$^\\textrm{TM}$$ Appliance~(GFA) controller, developed at Pacific Northwest National Laboratory, can autonomously switch off the appliances by detecting the under-frequency events. In this paper, the impacts of curtailing frequency threshold on the performance of frequency responsive GFAs are carefully analyzed first. The current method of selecting curtailing frequency thresholds for GFAs is found to be insufficient to guarantee the desired performance especially when the frequency deviation is shallow. In addition, the power reduction of online GFAs could be so excessive that it can even impact the system response negatively. As a remedy to the deficiency of the current controller design, a different way of selecting curtailing frequency thresholds is proposed to ensure the effectiveness of GFAs in frequency protection. Moreover, it is also proposed to introduce a supervisor at each distribution feeder to monitor the curtailing frequency thresholds of online GFAs and take corrective actions if necessary.« less

  5. Specific features of a single-pulse sliding discharge in neon near the threshold for spark breakdown

    NASA Astrophysics Data System (ADS)

    Trusov, K. K.

    2017-08-01

    Experimental data on the spatial structure of a single-pulse sliding discharge in neon at voltages below, equal to, and above the threshold for spark breakdown are discussed. The experiments were carried at gas pressures of 30 and 100 kPa and different polarities of the discharge voltage. Photographs of the plasma structure in two discharge chambers with different dimensions of the discharge zone and different thicknesses of an alumina dielectric plate on the surface of which the discharge develops are inspected. Common features of the prebreakdown discharge and its specific features depending on the voltage polarity and gas pressure are analyzed. It is shown that, at voltages below the threshold for spark breakdown, a low-current glow discharge with cathode and anode spots develops in the electrode gap. Above the breakdown threshold, regardless of the voltage polarity, spark channels directed from the cathode to the anode develop against the background of a low-current discharge.

  6. Atomic Data and Spectral Line Intensities for Ni XI

    NASA Technical Reports Server (NTRS)

    Bhatia, A. K.; Landi, E.

    2010-01-01

    Electron impact collision strengths, energy levels, oscillator strengths and spontaneous radiative decay rates are calculated for Ni XI. We include in the calculations the 10 lowest configurations, corresponding to 164 fine structure levels: 3s(sup 2)3p(sup 6), 3s(sup 2)3p(sup 5)3d, 3s(sup 2)3p(sup 4)3d(sup 2), 3s3p(sup 6)3d, 3s(sup 2)3p(sup 5)4l and 3s3p6 4l with l =.s, p, d. Collision strengths are calculated at five incident energies for all transitions: 7.1, 16.8, 30.2, 48.7 and 74.1 Ry above the threshold of each transition. An additional energy, very close to the transition threshold, has been added, whose value is between 0.06 Ry and 0.25 Ry depending on the lower level. Calculations have been carried out using the Flexible Atomic Code and the distorted wave approximation. Excitation rate coefficients are calculated as a function of electron temperature by assuming a Maxwellian electron velocity distribution. Using the excitation rate coefficients and the radiative transition rates of the present work, combined with Close Coupling collision excitation rate coefficient available in the literature for the lowest 17 levels, statistical equilibrium equations for level populations are solved at electron densities covering the 10(exp 8)-10(exp 14) cu cm range and at an electron temperature of logT(sub c)(K)=6.1, corresponding to the maximum abundance of Ni XI. Spectral line intensities are calculated, and their diagnostic relevance is discussed. This dataset will be made available in the next version of the CHIANTI database.

  7. Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

    NASA Technical Reports Server (NTRS)

    Waller, Jess M.; Williams, James H.; Fries, Joseph (Technical Monitor)

    1999-01-01

    The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

  8. Role of Cost on Failure to Access Prescribed Pharmaceuticals: The Case of Statins.

    PubMed

    McRae, Ian; van Gool, Kees; Hall, Jane; Yen, Laurann

    2017-10-01

    In Australia, as in many other Western countries, patient surveys suggest the costs of medicines lead to deferring or avoiding filling of prescriptions. The Australian Pharmaceutical Benefits Scheme provides approved prescription medicines at subsidised prices with relatively low patient co-payments. The Pharmaceutical Benefits Scheme defines patient co-payment levels per script depending on whether patients are "concessional" (holding prescribed pension or other government concession cards) or "general", and whether they have reached a safety net defined by total out-of-pocket costs for Pharmaceutical Benefits Scheme-approved medicines. The purpose of this study was to explore the impact of costs on adherence to statins in this relatively low-cost environment. Using data from a large-scale survey of older Australians in the state of New South Wales linked to administrative data from the national medical and pharmaceutical insurance schemes, we explore the relationships between adherence to medication regimes for statins and out-of-pocket costs of prescribed pharmaceuticals, income, other health costs, and a wide set of demographic and socio-economic control variables using both descriptive analysis and logistic regressions. Within the general non-safety net group, which has the highest co-payment, those with lowest income have the lowest adherence, suggesting that the general safety threshold may be set at a level that forms a major barrier to statin adherence. This is reinforced by over 75% of those who were not adherent before reaching the safety net threshold becoming adherent after reaching the safety net with its lower co-payments. The main financial determinant of adherence is the concessional/general and safety net category of the patient, which means the main determinant is the level of co-payment.

  9. Inhibitory effect of cervical trachea and chest wall vibrations on cough reflex sensitivity and perception of urge-to-cough in healthy male never-smokers

    PubMed Central

    2013-01-01

    Background Non-pharmacological options for symptomatic management of cough are desired. Although chest wall mechanical vibration is known to ameliorate cough reflex sensitivity, the effect of mechanical vibrations on perceptions of urge-to-cough has not been studied. Therefore, we investigated the effect of mechanical vibration of cervical trachea, chest wall and femoral muscle on cough reflex sensitivity, perceptions of urge-to-cough as well as dyspnea. Methods Twenty-four healthy male never-smokers were investigated for cough reflex sensitivity, perceptions of the urge-to-cough and dyspnea with or without mechanical vibration. Cough reflex sensitivity and urge-to-cough were evaluated by the inhalation of citric acid. The perception of dyspnea was evaluated by Borg scores during applications of external inspiratory resistive loads. Mechanical vibration was applied by placing a vibrating tuning fork on the skin surface of cervical trachea, chest wall and femoral muscle. Results Cervical trachea vibration significantly increased cough reflex threshold, as expressed by the lowest concentration of citric acid that elicited five or more coughs (C5), and urge-to-cough threshold, as expressed by the lowest concentration of citric acid that elicited urge-to-cough (Cu), but did not significantly affect dypnea sensation during inspiratory resistive loading. On the other hand, the chest wall vibration not only significantly increased C5 and Cu but also significantly ameliorated the load-response curve of dyspnea sensation. Conclusions Both cervical and trachea vibrations significantly inhibited cough reflex sensitivity and perception of urge-to-cough. These vibration techniques might be options for symptomatic cough management. PMID:24088411

  10. BMI, hypertension and low bone mineral density in adult men and women.

    PubMed

    Szklarska, Alicja; Lipowicz, Anna

    2012-08-01

    The aim of this work was to estimate the body mass index (BMI) at which risk of hypertension is lowest in men and women, while concurrently considering the protective role of adipose tissue in osteoporosis. Healthy, occupationally active inhabitants of the city of Wrocław, Poland, 1218 women and 434 men were studied. BMI, systolic and diastolic blood pressures, bone mineral density (BMD) of the trabecular compartment and distal radius of the non-dominant hand were recorded. Overweight in young women (≤45 years) was associated with increased risk of hypertension, whereas the risk of low bone mineral was decreased for the same BMI. In older women (>45 years), a BMI>27 was the threshold for increased risk of hypertension. In this age group, extremely slim women (BMI<21) had the highest risk of low bone mineral density. In younger males (≤45 years), risk of hypertension was lowest among the thinnest subjects (BMI<21). Increase in BMI over 21 kg/m(2) increased the risk of hypertension. The probability of low bone mineral density was the same in all BMI categories of men. In older men (>45 years), the thinnest (BMI<21) had higher risk of hypertension. To begin from BMI=25 kg/m(2), there was a monotonous increase in risk of hypertension in men. Higher risk for low bone mineral density was observed in older men with the BMI<23. Among younger adults, risk of hypertension and low bone mineral density increase at BMI≥21 kg/m(2) in men and BMI≥23 kg/m(2) in women. Among older men and women, the BMI threshold was 27 kg/m(2). Copyright © 2012 Elsevier GmbH. All rights reserved.

  11. Rational expectations, psychology and inductive learning via moving thresholds

    NASA Astrophysics Data System (ADS)

    Lamba, H.; Seaman, T.

    2008-06-01

    This paper modifies a previously introduced class of heterogeneous agent models in a way that allows for the inclusion of different types of agent motivations and behaviours in a consistent manner. The agents operate within a highly simplified environment where they are only able to be long or short one unit of the asset. The price of the asset is influenced by both an external information stream and the demand of the agents. The current strategy of each agent is defined by a pair of moving thresholds straddling the current price. When the price crosses either of the thresholds for a particular agent, that agent switches position and a new pair of thresholds is generated. The threshold dynamics can mimic different sources of investor motivation, running the gamut from purely rational information-processing, through rational (but often undesirable) behaviour induced by perverse incentives and moral hazards, to purely psychological effects. The simplest model of this kind precisely conforms to the Efficient Market Hypothesis (EMH) and this allows causal relationships to be established between actions at the agent level and violations of EMH price statistics at the global level. In particular, the effects of herding behaviour and perverse incentives are examined.

  12. A novel gate and drain engineered charge plasma tunnel field-effect transistor for low sub-threshold swing and ambipolar nature

    NASA Astrophysics Data System (ADS)

    Yadav, Dharmendra Singh; Raad, Bhagwan Ram; Sharma, Dheeraj

    2016-12-01

    In this paper, we focus on the improvement of figures of merit for charge plasma based tunnel field-effect transistor (TFET) in terms of ON-state current, threshold voltage, sub-threshold swing, ambipolar nature, and gate to drain capacitance which provides better channel controlling of the device with improved high frequency response at ultra-low supply voltages. Regarding this, we simultaneously employ work function engineering on the drain and gate electrode of the charge plasma TFET. The use of gate work function engineering modulates the barrier on the source/channel interface leads to improvement in the ON-state current, threshold voltage, and sub-threshold swing. Apart from this, for the first time use of work function engineering on the drain electrode increases the tunneling barrier for the flow of holes on the drain/channel interface, it results into suppression of ambipolar behavior. The lowering of gate to drain capacitance therefore enhanced high frequency parameters. Whereas, the presence of dual work functionality at the gate electrode and over the drain region improves the overall performance of the charge plasma based TFET.

  13. Robot gripper

    NASA Technical Reports Server (NTRS)

    Webb, Winston S. (Inventor)

    1987-01-01

    An electronic force-detecting robot gripper for gripping objects and attaching to an external robot arm is disclosed. The gripper comprises motor apparatus, gripper jaws, and electrical circuits for driving the gripper motor and sensing the amount of force applied by the jaws. The force applied by the jaws is proportional to a threshold value of the motor current. When the motor current exceeds the threshold value, the electrical circuits supply a feedback signal to the electrical control circuit which, in turn, stops the gripper motor.

  14. Timing discriminator using leading-edge extrapolation

    DOEpatents

    Gottschalk, B.

    1981-07-30

    A discriminator circuit to recover timing information from slow-rising pulses by means of an output trailing edge, a fixed time after the starting corner of the input pulse, which is nearly independent of risetime and threshold setting is described. This apparatus comprises means for comparing pulses with a threshold voltage; a capacitor to be charged at a certain rate when the input signal is one-third threshold voltage, and at a lower rate when the input signal is two-thirds threshold voltage; current-generating means for charging the capacitor; means for comparing voltage capacitor with a bias voltage; a flip-flop to be set when the input pulse reaches threshold voltage and reset when capacitor voltage reaches the bias voltage; and a clamping means for discharging the capacitor when the input signal returns below one-third threshold voltage.

  15. Application of Key Events and Analysis to Chemical Carcinogens and Noncarcinogens

    EPA Science Inventory

    The existence of thresholds for toxicants is a matter of debate in chemical rsk assessment and regulation. Current risk assessment methods are based on the assumption that, in the basense of sufficient data, carcinogenesis does not have a threshold, while non-carcinogenic endpoi...

  16. Transistor biased amplifier minimizes diode discriminator threshold attenuation

    NASA Technical Reports Server (NTRS)

    Larsen, R. N.

    1967-01-01

    Transistor biased amplifier has a biased diode discriminator driven by a high impedance /several megohms/ current source, rather than a voltage source with several hundred ohms output impedance. This high impedance input arrangement makes the incremental impedance of the threshold diode negligible relative to the input impedance.

  17. Final Rule: Extremely Hazardous Substance List and Threshold Planning Quantities; Emergency Planning and Release Notification Requirements (52 FR 13378)

    EPA Pesticide Factsheets

    April 22, 1987: This FR established the list of extremely hazardous substances (EHSs) and their threshold planning quantities (TPQs). Also codified reporting and notification requirements for facilities with EHS. Do not use for current compliance purposes.

  18. 78 FR 8054 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-05

    ..., dated March 5, 1990) has not been done as of August 31, 2004 (the effective date of AD 2004-15-07... A310 series airplanes. The existing AD currently requires repetitive inspections for fatigue cracking... fatigue threshold and inspection interval resulted in a determination that reduced inspection thresholds...

  19. Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

    NASA Technical Reports Server (NTRS)

    Ebert, Douglas; Macias, Brandon; Sargsyan, Ashot; Garcia, Kathleen; Stenger, Michael; Hargens, Alan; Johnston, Smith; Kemp, David; Danielson, Richard

    2017-01-01

    Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs and lower body negative pressure (LBNP) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure.

  20. Compact universal logic gates realized using quantization of current in nanodevices.

    PubMed

    Zhang, Wancheng; Wu, Nan-Jian; Yang, Fuhua

    2007-12-12

    This paper proposes novel universal logic gates using the current quantization characteristics of nanodevices. In nanodevices like the electron waveguide (EW) and single-electron (SE) turnstile, the channel current is a staircase quantized function of its control voltage. We use this unique characteristic to compactly realize Boolean functions. First we present the concept of the periodic-threshold threshold logic gate (PTTG), and we build a compact PTTG using EW and SE turnstiles. We show that an arbitrary three-input Boolean function can be realized with a single PTTG, and an arbitrary four-input Boolean function can be realized by using two PTTGs. We then use one PTTG to build a universal programmable two-input logic gate which can be used to realize all two-input Boolean functions. We also build a programmable three-input logic gate by using one PTTG. Compared with linear threshold logic gates, with the PTTG one can build digital circuits more compactly. The proposed PTTGs are promising for future smart nanoscale digital system use.

  1. Phenytoin preferentially inhibits L-type calcium currents in whole-cell patch-clamped cardiac and skeletal muscle cells.

    PubMed

    Rivet, M; Bois, P; Cognard, C; Raymond, G

    1990-10-01

    The effect of the anticonvulsant diphenylhydantoin (phenytoin) was tested on the inward calcium currents of whole-cell patch-clamped cells from rat and human muscles and from frog atrium. A concentration of 10 microM phenytoin was required to obtain a threshold inhibitory effect and, even with high concentrations (100 microM), the inhibition was not complete. In skeletal muscle (rat and human cells in culture), phenytoin (30 microM) exerted a more potent effect on the high-threshold calcium current (ICa,L inhibition: 53 +/- 6% mean +/- SDn-1) rather than on the low-threshold one (ICa,T inhibition: 16 +/- 10%). Similar results were obtained on dissociated frog atrial cells. These data are to be contrasted with those previously reported on neuronal cells, where specific inhibition of ICa,T was reported. Thus, the action of phenytoin appears to be different in muscle and nerve so that phenytoin does not appear to be a specific inhibitor of ICa,T.

  2. Study protocol of hypoalgesic effects of low frequency and burst-modulated alternating currents on healthy individuals.

    PubMed

    Rampazo da Silva, Érika Patrícia; da Silva, Viviane Ribeiro; Bernardes, Anabelly Sato; Matuzawa, Fabio Massao; Liebano, Richard Eloin

    2018-03-01

    The aim of the study will be to compare different types of analgesic electrical currents in relation to the pressure pain threshold and sensory comfort in healthy individuals. A total of 100 individuals will be randomly assigned to four groups: transcutaneous electrical nerve stimulation, interferential current, Aussie current or placebo. The electrical stimulation will be administered with a strong level for 30 min and to the placebo group, the electrodes will be positioned while the equipment will remain switched off. The pressure pain threshold and sensory comfort will be measured with an algometer and the visual analogue scale, respectively. The level of significance will be p < 0.05. NCT01950728 (clinical trials).

  3. CROSS-DISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Environmental Impacts on Spiking Properties in Hodgkin-Huxley Neuron with Direct Current Stimulus

    NASA Astrophysics Data System (ADS)

    Yuan, Chang-Qing; Zhao, Tong-Jun; Zhan, Yong; Zhang, Su-Hua; Liu, Hui; Zhang, Yu-Hong

    2009-11-01

    Based on the well accepted Hodgkin-Huxley neuron model, the neuronal intrinsic excitability is studied when the neuron is subject to varying environmental temperatures, the typical impact for its regulating ways. With computer simulation, it is found that altering environmental temperature can improve or inhibit the neuronal intrinsic excitability so as to influence the neuronal spiking properties. The impacts from environmental factors can be understood that the neuronal spiking threshold is essentially influenced by the fluctuations in the environment. With the environmental temperature varying, burst spiking is realized for the neuronal membrane voltage because of the environment-dependent spiking threshold. This burst induced by changes in spiking threshold is different from that excited by input currents or other stimulus.

  4. Model for Predicting Passage of Invasive Fish Species Through Culverts

    NASA Astrophysics Data System (ADS)

    Neary, V.

    2010-12-01

    Conservation efforts to promote or inhibit fish passage include the application of simple fish passage models to determine whether an open channel flow allows passage of a given fish species. Derivations of simple fish passage models for uniform and nonuniform flow conditions are presented. For uniform flow conditions, a model equation is developed that predicts the mean-current velocity threshold in a fishway, or velocity barrier, which causes exhaustion at a given maximum distance of ascent. The derivation of a simple expression for this exhaustion-threshold (ET) passage model is presented using kinematic principles coupled with fatigue curves for threatened and endangered fish species. Mean current velocities at or above the threshold predict failure to pass. Mean current velocities below the threshold predict successful passage. The model is therefore intuitive and easily applied to predict passage or exclusion. The ET model’s simplicity comes with limitations, however, including its application only to uniform flow, which is rarely found in the field. This limitation is addressed by deriving a model that accounts for nonuniform conditions, including backwater profiles and drawdown curves. Comparison of these models with experimental data from volitional swimming studies of fish indicates reasonable performance, but limitations are still present due to the difficulty in predicting fish behavior and passage strategies that can vary among individuals and different fish species.

  5. BeZnCdSe quantum-well ridge-waveguide laser diodes under low threshold room-temperature continuous-wave operation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Jijun; Electronics and Photonics Research Institute, National Institute of Advanced Industrial Science and Technology; Akimoto, Ryoichi, E-mail: r-akimoto@aist.go.jp

    2015-10-19

    Low threshold current ridge-waveguide BeZnCdSe quantum-well laser diodes (LDs) have been developed by completely etching away the top p-type BeMgZnSe/ZnSe:N short-period superlattice cladding layer, which can suppress the leakage current that flows laterally outside of the electrode. The waveguide LDs are covered with a thick SiO{sub 2} layer and planarized with chemical-mechanical polishing and a reactive ion etching process. Room-temperature lasing under continuous-wave condition is achieved with the laser cavity formed by the cleaved waveguide facets coated with high-reflectivity dielectric films. For a 4 μm-wide green LD lasing around a wavelength of 535 nm, threshold current and voltage of 7.07 mA and 7.89 Vmore » are achieved for a cavity length of 300 μm, and the internal differential quantum efficiency, internal absorption loss, gain constant, and nominal transparency current density are estimated to be 27%, 4.09 cm{sup −1}, 29.92 (cm × μm)/kA and 6.35 kA/(cm{sup 2 }× μm), respectively. This compact device can realize a significantly improved performance with much lower threshold power consumption, which would benefit the potential application for ZnSe-based green LDs as light sources in full-color display and projector devices installed in consumer products such as pocket projectors.« less

  6. Statistical properties of a filtered Poisson process with additive random noise: distributions, correlations and moment estimation

    NASA Astrophysics Data System (ADS)

    Theodorsen, A.; E Garcia, O.; Rypdal, M.

    2017-05-01

    Filtered Poisson processes are often used as reference models for intermittent fluctuations in physical systems. Such a process is here extended by adding a noise term, either as a purely additive term to the process or as a dynamical term in a stochastic differential equation. The lowest order moments, probability density function, auto-correlation function and power spectral density are derived and used to identify and compare the effects of the two different noise terms. Monte-Carlo studies of synthetic time series are used to investigate the accuracy of model parameter estimation and to identify methods for distinguishing the noise types. It is shown that the probability density function and the three lowest order moments provide accurate estimations of the model parameters, but are unable to separate the noise types. The auto-correlation function and the power spectral density also provide methods for estimating the model parameters, as well as being capable of identifying the noise type. The number of times the signal crosses a prescribed threshold level in the positive direction also promises to be able to differentiate the noise type.

  7. Temperature effects on tunable cw Alexandrite lasers under diode end-pumping.

    PubMed

    Kerridge-Johns, William R; Damzen, Michael J

    2018-03-19

    Diode pumped Alexandrite is a promising route to high power, efficient and inexpensive lasers with a broad (701 nm to 858 nm) gain bandwidth; however, there are challenges with its complex laser dynamics. We present an analytical model applied to experimental red diode end-pumped Alexandrite lasers, which enabled a record 54 % slope efficiency with an output power of 1.2 W. A record lowest lasing wavelength (714 nm) and record tuning range (104 nm) was obtained by optimising the crystal temperature between 8 °C and 105 °C in the vibronic mode. The properties of Alexandrite and the analytical model were examined to understand and give general rules in optimising Alexandrite lasers, along with their fundamental efficiency limits. It was found that the lowest threshold laser wavelength was not necessarily the most efficient, and that higher and lower temperatures were optimal for longer and shorter laser wavelengths, respectively. The pump excited to ground state absorption ratio was measured to decrease from 0.8 to 0.7 by changing the crystal temperature from 10 °C to 90 °C.

  8. Speech Recognition Thresholds for Multilingual Populations.

    ERIC Educational Resources Information Center

    Ramkissoon, Ishara

    2001-01-01

    This article traces the development of speech audiometry in the United States and reports on the current status, focusing on the needs of a multilingual population in terms of measuring speech recognition threshold (SRT). It also discusses sociolinguistic considerations, alternative SRT stimuli for second language learners, and research on using…

  9. Handwriting Automaticity: The Search for Performance Thresholds

    ERIC Educational Resources Information Center

    Medwell, Jane; Wray, David

    2014-01-01

    Evidence is accumulating that handwriting has an important role in written composition. In particular, handwriting automaticity appears to relate to success in composition. This relationship has been little explored in British contexts and we currently have little idea of what threshold performance levels might be. In this paper, we report on two…

  10. Comparison of two insulin assays for first-phase insulin release in type 1 diabetes prediction and prevention studies.

    PubMed

    Mahon, Jeffrey L; Beam, Craig A; Marcovina, Santica M; Boulware, David C; Palmer, Jerry P; Winter, William E; Skyler, Jay S; Krischer, Jeffrey P

    2011-11-20

    Detection of below-threshold first-phase insulin release or FPIR (1+3 minute insulin concentrations during an intravenous glucose tolerance test [IVGTT]) is important in type 1 diabetes prediction and prevention studies including the TrialNet Oral Insulin Prevention Trial. We assessed whether an insulin immunoenzymometric assay (IEMA) could replace the less practical but current standard of a radioimmunoassay (RIA) for FPIR. One hundred thirty-three islet autoantibody positive relatives of persons with type 1 diabetes underwent 161 IVGTTs. Insulin concentrations were measured by both assays in 1056 paired samples. A rule classifying FPIR (below-threshold, above-threshold, uncertain) by the IEMA was derived and validated against FPIR by the RIA. The insulin IEMA-based rule accurately classified below- and above-threshold FPIRs by the RIA in 110/161 (68%) IVGTTs, but was uncertain in 51/161 (32%) tests for which FPIR by RIA is needed. An uncertain FPIR by the IEMA was more likely among below-threshold vs above-threshold FPIRs by the RIA (64% [30/47] vs. 18% [21/114], respectively; p<0.05). An insulin IEMA for FPIR in subjects at risk for type 1 diabetes accurately determined below- and above-threshold FPIRs in 2/3 of tests relative to the current standard of the insulin RIA, but could not reliably classify the remaining FPIRs. TrialNet is limiting the insulin RIA for FPIR to the latter given the practical advantages of the more specific IEMA. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Gender, genetic risk, and criminal behavior.

    PubMed

    Vaske, Jamie; Wright, John Paul; Boisvert, Danielle; Beaver, Kevin Michael

    2011-02-28

    The threshold hypothesis asserts that the prevalence of offending is lower among females because females have a higher threshold for risk than males. As a result, females who do offend should exhibit greater concentrations of genetic and environmental risk than male offenders. In light of these statements, the current study examines the role of genetic factors in the etiology of female offending using data from the National Longitudinal Study of Adolescent Health. The results reveal that the genetic risk threshold is higher for females than for males. However, contrary to the threshold hypothesis, female offenders exhibit fewer genetic risks than male offenders. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  12. Efficacy and predictability of soft tissue ablation using a prototype Raman-shifted alexandrite laser

    NASA Astrophysics Data System (ADS)

    Kozub, John A.; Shen, Jin-H.; Joos, Karen M.; Prasad, Ratna; Shane Hutson, M.

    2015-10-01

    Previous research showed that mid-infrared free-electron lasers could reproducibly ablate soft tissue with little collateral damage. The potential for surgical applications motivated searches for alternative tabletop lasers providing thermally confined pulses in the 6- to-7-μm wavelength range with sufficient pulse energy, stability, and reliability. Here, we evaluate a prototype Raman-shifted alexandrite laser. We measure ablation thresholds, etch rates, and collateral damage in gelatin and cornea as a function of laser wavelength (6.09, 6.27, or 6.43 μm), pulse energy (up to 3 mJ/pulse), and spot diameter (100 to 600 μm). We find modest wavelength dependence for ablation thresholds and collateral damage, with the lowest thresholds and least damage for 6.09 μm. We find a strong spot-size dependence for all metrics. When the beam is tightly focused (˜100-μm diameter), ablation requires more energy, is highly variable and less efficient, and can yield large zones of mechanical damage (for pulse energies >1 mJ). When the beam is softly focused (˜300-μm diameter), ablation proceeded at surgically relevant etch rates, with reasonable reproducibility (5% to 12% within a single sample), and little collateral damage. With improvements in pulse-energy stability, this prototype laser may have significant potential for soft-tissue surgical applications.

  13. Theoretical studies of the potential surface for the F - H2 greater than HF + H reaction

    NASA Technical Reports Server (NTRS)

    Bauschlicher, Charles W., Jr.; Walch, Stephen, P.; Langhoff, Stephen R.; Taylor, Peter R.; Jaffe, Richard L.

    1987-01-01

    The F + H2 yields HF + H potential energy hypersurface was studied in the saddle point and entrance channel regions. Using a large (5s 5p 3d 2f 1g/4s 3p 2d) atomic natural orbital basis set, a classical barrier height of 1.86 kcal/mole was obtained at the CASSCF/multireference CI level (MRCI) after correcting for basis set superposition error and including a Davidson correction (+Q) for higher excitations. Based upon an analysis of the computed results, the true classical barrier is estimated to be about 1.4 kcal/mole. The location of the bottleneck on the lowest vibrationally adiabatic potential curve was also computed and the translational energy threshold determined from a one-dimensional tunneling calculation. Using the difference between the calculated and experimental threshold to adjust the classical barrier height on the computed surface yields a classical barrier in the range of 1.0 to 1.5 kcal/mole. Combining the results of the direct estimates of the classical barrier height with the empirical values obtained from the approximation calculations of the dynamical threshold, it is predicted that the true classical barrier height is 1.4 + or - 0.4 kcal/mole. Arguments are presented in favor of including the relatively large +Q correction obtained when nine electrons are correlated at the CASSCF/MRCI level.

  14. Efficacy and predictability of soft tissue ablation using a prototype Raman-shifted alexandrite laser

    PubMed Central

    Kozub, John A.; Shen, Jin-H.; Joos, Karen M.; Prasad, Ratna; Shane Hutson, M.

    2015-01-01

    Abstract. Previous research showed that mid-infrared free-electron lasers could reproducibly ablate soft tissue with little collateral damage. The potential for surgical applications motivated searches for alternative tabletop lasers providing thermally confined pulses in the 6- to-7-μm wavelength range with sufficient pulse energy, stability, and reliability. Here, we evaluate a prototype Raman-shifted alexandrite laser. We measure ablation thresholds, etch rates, and collateral damage in gelatin and cornea as a function of laser wavelength (6.09, 6.27, or 6.43  μm), pulse energy (up to 3  mJ/pulse), and spot diameter (100 to 600  μm). We find modest wavelength dependence for ablation thresholds and collateral damage, with the lowest thresholds and least damage for 6.09  μm. We find a strong spot-size dependence for all metrics. When the beam is tightly focused (∼100-μm diameter), ablation requires more energy, is highly variable and less efficient, and can yield large zones of mechanical damage (for pulse energies >1  mJ). When the beam is softly focused (∼300-μm diameter), ablation proceeded at surgically relevant etch rates, with reasonable reproducibility (5% to 12% within a single sample), and little collateral damage. With improvements in pulse-energy stability, this prototype laser may have significant potential for soft-tissue surgical applications. PMID:26456553

  15. {omega} meson production in pp collisions with a polarized beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balasubramanyam, J.; Venkataraya,; Ramachandran, G.

    2008-07-15

    Model independent formulas are derived for the beam analyzing power A{sub y} and beam to meson spin transfers in pp{yields}pp{omega}, taking into consideration all six threshold partial wave amplitudes f{sub 1},...,f{sub 6} covering the Ss, Sp, and Ps channels. It is shown that the lowest three partial wave amplitudes f{sub 1},f{sub 2},f{sub 3} can be determined empirically without any discrete ambiguities. Partial information with regard to the amplitudes f{sub 4},f{sub 5},f{sub 6} covering the Ps channel may be extracted, if the measurements are carried through at the double differential level.

  16. Investigation of the refractive index repeatability for tantalum pentoxide coatings, prepared by physical vapor film deposition techniques.

    PubMed

    Stenzel, O; Wilbrandt, S; Wolf, J; Schürmann, M; Kaiser, N; Ristau, D; Ehlers, H; Carstens, F; Schippel, S; Mechold, L; Rauhut, R; Kennedy, M; Bischoff, M; Nowitzki, T; Zöller, A; Hagedorn, H; Reus, H; Hegemann, T; Starke, K; Harhausen, J; Foest, R; Schumacher, J

    2017-02-01

    Random effects in the repeatability of refractive index and absorption edge position of tantalum pentoxide layers prepared by plasma-ion-assisted electron-beam evaporation, ion beam sputtering, and magnetron sputtering are investigated and quantified. Standard deviations in refractive index between 4*10-4 and 4*10-3 have been obtained. Here, lowest standard deviations in refractive index close to our detection threshold could be achieved by both ion beam sputtering and plasma-ion-assisted deposition. In relation to the corresponding mean values, the standard deviations in band-edge position and refractive index are of similar order.

  17. Marine mammal audibility of selected shallow-water survey sources.

    PubMed

    MacGillivray, Alexander O; Racca, Roberto; Li, Zizheng

    2014-01-01

    Most attention about the acoustic effects of marine survey sound sources on marine mammals has focused on airgun arrays, with other common sources receiving less scrutiny. Sound levels above hearing threshold (sensation levels) were modeled for six marine mammal species and seven different survey sources in shallow water. The model indicated that odontocetes were most likely to hear sounds from mid-frequency sources (fishery, communication, and hydrographic systems), mysticetes from low-frequency sources (sub-bottom profiler and airguns), and pinnipeds from both mid- and low-frequency sources. High-frequency sources (side-scan and multibeam) generated the lowest estimated sensation levels for all marine mammal species groups.

  18. Beauty and charm production in fixed target experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kidonakis, Nikolaos; Vogt, Ramona

    We present calculations of NNLO threshold corrections for beauty and charm production in {pi}{sup -} p and pp interactions at fixed-target experiments. Recent calculations for heavy quark hadroproduction have included next-to-next-to-leading-order (NNLO) soft-gluon corrections [1] to the double differential cross section from threshold resummation techniques [2]. These corrections are important for near-threshold beauty and charm production at fixed-target experiments, including HERA-B and some of the current and future heavy ion experiments.

  19. Severe wind gust thresholds for Meteoalarm derived from uniform return periods in ECA&D

    NASA Astrophysics Data System (ADS)

    Stepek, A.; Wijnant, I. L.; van der Schrier, G.; van den Besselaar, E. J. M.; Klein Tank, A. M. G.

    2012-06-01

    In this study we present an alternative wind gust warning guideline for Meteoalarm, the severe weather warning website for Europe. There are unrealistically large differences in levels and issuing frequencies of all warning levels currently in use between neighbouring Meteoalarm countries. This study provides a guide for the Meteoalarm community to review their wind gust warning thresholds. A more uniform warning system is achieved by using one pan-European return period per warning level. The associated return values will be different throughout Europe because they depend on local climate conditions, but they will not change abruptly at country borders as is currently the case for the thresholds. As return values are a measure of the possible danger of an event and its impact on society, they form an ideal basis for a warning system. Validated wind gust measurements from the European Climate Assessment and Dataset (ECA&D, http://www.ecad.eu) were used to calculate return values of the annual maximum wind gust. The current thresholds are compared with return values for 3 different return periods: 10 times a year return periods for yellow warnings, 2 yr periods for orange and 5 yr periods for red warnings. So far 10 countries provide wind gust data to ECA&D. Due to the ECA&D completeness requirements and the fact that some countries provided too few stations to be representative for that country, medians of the return values of annual maximum wind gust could be calculated for 6 of the 10 countries. Alternative guideline thresholds are presented for Norway, Ireland, The Netherlands, Germany, the Czech Republic and Spain and the need to distinguish between coastal, inland and mountainous regions is demonstrated. The new thresholds based on uniform return periods differ significantly from the current ones, particularly for coastal and mountainous areas. We are aware of other, sometimes binding factors (e.g. laws) that prevent participating counties from implementing this climatology based warning system.

  20. Hierarchical Approach to 'Atomistic' 3-D MOSFET Simulation

    NASA Technical Reports Server (NTRS)

    Asenov, Asen; Brown, Andrew R.; Davies, John H.; Saini, Subhash

    1999-01-01

    We present a hierarchical approach to the 'atomistic' simulation of aggressively scaled sub-0.1 micron MOSFET's. These devices are so small that their characteristics depend on the precise location of dopant atoms within them, not just on their average density. A full-scale three-dimensional drift-diffusion atomistic simulation approach is first described and used to verify more economical, but restricted, options. To reduce processor time and memory requirements at high drain voltage, we have developed a self-consistent option based on a solution of the current continuity equation restricted to a thin slab of the channel. This is coupled to the solution of the Poisson equation in the whole simulation domain in the Gummel iteration cycles. The accuracy of this approach is investigated in comparison to the full self-consistent solution. At low drain voltage, a single solution of the nonlinear Poisson equation is sufficient to extract the current with satisfactory accuracy. In this case, the current is calculated by solving the current continuity equation in a drift approximation only, also in a thin slab containing the MOSFET channel. The regions of applicability for the different components of this hierarchical approach are illustrated in example simulations covering the random dopant-induced threshold voltage fluctuations, threshold voltage lowering, threshold voltage asymmetry, and drain current fluctuations.

  1. Contraction produced by intracellular injection of calcium, strontium, and barium in the single crayfish muscle fibers.

    PubMed

    Matsumura, M; Mashima, H

    1976-01-01

    Ca ions were ionophoretically injected through an intracellular microelectrode into the single muscle fiber of a crayfish, and the resulting contraction sphere was observed under a microscope and photographed with a movie camera. The minimum contraction produced by the threshold current involved usually three or four, sometimes two, sarcomers on both sides of the injecting pipette but contraction involving only one sarcomere was not observered. The rheobase of the Ca-injecting current was 3.2 X 10(-9) A. The strength-duration curves were determined for Ca-, Sr-, and Ba-injecting currents; all fitted a similar hyperbolic equation. The threshold amount of Ca above rheobasic injection was 2.1 X 10(-15)mol, and the ratios between threshold amounts were Ca: Sr: Ba=1: 1.9: 3.0. The effects of Ca and Sr were additive for the contraction. More current was required for the Ca-injection to produce the contraction in the K-depolarized-or 15mM-procaine-treated muscle, although less current was sufficient for the muscle treated with 0.5-1.0 mM of caffeine. The participation of the Ca-induced Ca release mechanism in the contraction produced by Ca injection and the role of Sr or Ba as a substitute for Ca were discussed.

  2. Personalizing annual lung cancer screening for patients with chronic obstructive pulmonary disease: A decision analysis.

    PubMed

    Lowry, Kathryn P; Gazelle, G Scott; Gilmore, Michael E; Johanson, Colden; Munshi, Vidit; Choi, Sung Eun; Tramontano, Angela C; Kong, Chung Yin; McMahon, Pamela M

    2015-05-15

    Lung cancer screening with annual chest computed tomography (CT) is recommended for current and former smokers with a ≥30-pack-year smoking history. Patients with chronic obstructive pulmonary disease (COPD) are at increased risk of developing lung cancer and may benefit from screening at lower pack-year thresholds. We used a previously validated simulation model to compare the health benefits of lung cancer screening in current and former smokers ages 55-80 with ≥30 pack-years with hypothetical programs using lower pack-year thresholds for individuals with COPD (≥20, ≥10, and ≥1 pack-years). Calibration targets for COPD prevalence and associated lung cancer risk were derived using the Framingham Offspring Study limited data set. We performed sensitivity analyses to evaluate the stability of results across different rates of adherence to screening, increased competing mortality risk from COPD, and increased surgical ineligibility in individuals with COPD. The primary outcome was projected life expectancy. Programs using lower pack-year thresholds for individuals with COPD yielded the highest life expectancy gains for a given number of screens. Highest life expectancy was achieved when lowering the pack-year threshold to ≥1 pack-year for individuals with COPD, which dominated all other screening strategies. These results were stable across different adherence rates to screening and increases in competing mortality risk for COPD and surgical ineligibility. Current and former smokers with COPD may disproportionately benefit from lung cancer screening. A lower pack-year threshold for screening eligibility may benefit this high-risk patient population. © 2015 American Cancer Society.

  3. Measurement of weak electric currents in copper wire phantoms using MRI: influence of susceptibility enhancement.

    PubMed

    Huang, Ruiwang; Posnansky, Oleg; Celik, Abdullah; Oros-Peusquens, Ana-Maria; Ermer, Veronika; Irkens, Marco; Wegener, H-Peter; Shah, N Jon

    2006-08-01

    The use of magnetic resonance imaging (MRI)-based methods for the direct detection of neuronal currents is a topic of intense investigation. Much experimental work has been carried out with the express aim of establishing detection thresholds and sensitivity to flowing currents. However, in most of these experiments, magnetic susceptibility enhancement was ignored. In this work, we present results that show the influence of a susceptibility artefact on the detection threshold and sensitivity. For this purpose, a novel phantom, consisting of a water-filled cylinder with two wires of different materials connected in series, was constructed. Magnitude MR images were acquired from a single slice using a gradient-echo echo planar imaging (EPI) sequence. The data show that the time course of the detected MR signal magnitude correlates very well with the waveform of the input current. The effect of the susceptibility artefacts arising from the two different wires was examined by comparing the magnitudes of the MR signals at different voxel locations. Our results indicate the following: (1) MR signal enhancement arising from the magnetic susceptibility effect influences the detection sensitivity of weak current; (2) the detection threshold and sensitivity are phantom-wire dependent; (3) sub-mu A electric current detection in a phantom is possible on a 1.5-T MR scanner in the presence of susceptibility enhancement.

  4. Non-equilibrium Green's functions study of discrete dopants variability on an ultra-scaled FinFET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valin, R., E-mail: r.valinferreiro@swansea.ac.uk; Martinez, A., E-mail: a.e.Martinez@swansea.ac.uk; Barker, J. R., E-mail: john.barker@glasgow.ac.uk

    In this paper, we study the effect of random discrete dopants on the performance of a 6.6 nm channel length silicon FinFET. The discrete dopants have been distributed randomly in the source/drain region of the device. Due to the small dimensions of the FinFET, a quantum transport formalism based on the non-equilibrium Green's functions has been deployed. The transfer characteristics for several devices that differ in location and number of dopants have been calculated. Our results demonstrate that discrete dopants modify the effective channel length and the height of the source/drain barrier, consequently changing the channel control of the charge. Thismore » effect becomes more significant at high drain bias. As a consequence, there is a strong effect on the variability of the on-current, off-current, sub-threshold slope, and threshold voltage. Finally, we have also calculated the mean and standard deviation of these parameters to quantify their variability. The obtained results show that the variability at high drain bias is 1.75 larger than at low drain bias. However, the variability of the on-current, off-current, and sub-threshold slope remains independent of the drain bias. In addition, we have found that a large source to drain current by tunnelling current occurs at low gate bias.« less

  5. Auditory sensitivity to spectral modulation phase reversal as a function of modulation depth

    PubMed Central

    Grose, John

    2018-01-01

    The present study evaluated auditory sensitivity to spectral modulation by determining the modulation depth required to detect modulation phase reversal. This approach may be preferable to spectral modulation detection with a spectrally flat standard, since listeners appear unable to perform the task based on the detection of temporal modulation. While phase reversal thresholds are often evaluated by holding modulation depth constant and adjusting modulation rate, holding rate constant and adjusting modulation depth supports rate-specific assessment of modulation processing. Stimuli were pink noise samples, filtered into seven octave-wide bands (0.125–8 kHz) and spectrally modulated in dB. Experiment 1 measured performance as a function of modulation depth to determine appropriate units for adaptive threshold estimation. Experiment 2 compared thresholds in dB for modulation detection with a flat standard and modulation phase reversal; results supported the idea that temporal cues were available at high rates for the former but not the latter. Experiment 3 evaluated spectral modulation phase reversal thresholds for modulation that was restricted to either one or two neighboring bands. Flanking bands of unmodulated noise had a larger detrimental effect on one-band than two-band targets. Thresholds for high-rate modulation improved with increasing carrier frequency up to 2 kHz, whereas low-rate modulation appeared more consistent across frequency, particularly in the two-band condition. Experiment 4 measured spectral weights for spectral modulation phase reversal detection and found higher weights for bands in the spectral center of the stimulus than for the lowest (0.125 kHz) or highest (8 kHz) band. Experiment 5 compared performance for highly practiced and relatively naïve listeners, and found weak evidence of a larger practice effect at high than low spectral modulation rates. These results provide preliminary data for a task that may provide a better estimate of sensitivity to spectral modulation than spectral modulation detection with a flat standard. PMID:29621338

  6. Modeling applications for precision agriculture in the California Central Valley

    NASA Astrophysics Data System (ADS)

    Marklein, A. R.; Riley, W. J.; Grant, R. F.; Mezbahuddin, S.; Mekonnen, Z. A.; Liu, Y.; Ying, S.

    2017-12-01

    Drought in California has increased the motivation to develop precision agriculture, which uses observations to make site-specific management decisions throughout the growing season. In agricultural systems that are prone to drought, these efforts often focus on irrigation efficiency. Recent improvements in soil sensor technology allow the monitoring of plant and soil status in real-time, which can then inform models aimed at improving irrigation management. But even on farms with resources to deploy soil sensors across the landscape, leveraging that sensor data to design an efficient irrigation scheme remains a challenge. We conduct a modeling experiment aimed at simulating precision agriculture to address several questions: (1) how, when, and where does irrigation lead to optimal yield? and (2) What are the impacts of different precision irrigation schemes on yields, soil organic carbon (SOC), and total water use? We use the ecosys model to simulate precision agriculture in a conventional tomato-corn rotation in the California Central Valley with varying soil water content thresholds for irrigation and soil water sensor depths. This model is ideal for our question because it includes explicit process-based functions for the plant growth, plant water use, soil hydrology, and SOC, and has been tested extensively in agricultural ecosystems. Low irrigation thresholds allows the soil to become drier before irrigating compared to high irrigation thresholds; as such, we found that the high irrigation thresholds use more irrigation over the course of the season, have higher yields, and have lower water use efficiency. The irrigation threshold did not affect SOC. Yields and water use are highest at sensor depths of 0.5 to 0.15 m, but water use efficiency was also lowest at these depths. We found SOC to be significantly affected by sensor depth, with the highest SOC at the shallowest sensor depths. These results will help regulate irrigation water while maintaining yield in California, especially with uncertain precipitation regimes.

  7. A comparison of the antinociceptive effects of xylazine, detomidine and romifidine on experimental pain in horses.

    PubMed

    Moens, Yves; Lanz, Francisca; Doherr, Marcus G; Schatzmann, Urs

    2003-07-01

    To study the analgesic potency of the alpha2-agonist romifidine in the horse using both an electrical current and a mechanical pressure model for nociceptive threshold testing. In addition, a comparison was made with doses of detomidine and xylazine that produce equivalent degrees of sedation. Randomized, placebo-controlled, blinded cross-over study. Six adult Swiss warmblood horses, one mare and five geldings, weighing from 530 to 650 kg and aged 6-15 years. Nociceptive thresholds were measured using an electrical stimulus applied to the coronary band and using a pneumatically operated pin pressing on the cannon bone. Measurements were made immediately before and every 15 minutes for 2 hours after IV injection of the test substances. Lifting of the foot indicated the test end point. The three alpha2-agonists caused a temporary increase in nociceptive thresholds with a maximal effect within 15 minutes and a return to baseline levels within 1 hour. Using electrical current testing nociceptive thresholds were significantly different from placebo (mean +/- SD) for detomidine at 15 minutes (from control 5.8 +/- 0.9 to 23.3 +/- 3.9 mA, p = 0.0066) and 30 minutes (from control 6.6 +/- 1.1 to 18.8 +/- 3.3 mA, p = 0.0091). The difference was significant for romifidine at 15 minutes only (from control 5.8 +/- 0.9 to 18.7 +/- 3.8 mA, p = 0.0066). With mechanical pressure testing nociceptive thresholds were significantly different from control for detomidine at 15 minutes (from 3.2 +/- 0.2 to 6.2 +/- 0.5 N, p = 0.00076) and 30 minutes (from 3.2 +/- 0.7 to 5.7 +/- 0.8 N, p = 0.0167). The difference was significant for xylazine at 15 minutes (from control 3.2 +/- 0.2 to 5.6 +/- 0.7 N, p = 0.0079). At 15 minutes the order of magnitude of the measured antinociceptive effect was significantly different between the two pain tests for both romifidine and detomidine, but not for xylazine. For romifidine, the increase of mean thresholds compared to placebo was 4.0 +/- 1.3 times placebo levels with the electrical current test compared to 1.3 +/- 0.3 times for the mechanical pressure test (p = 0.037). For detomidine, the increase of mean thresholds compared to placebo was 5.4 +/- 1.7 times control levels with the electrical current test compared to 2.0 +/- 0.2 times for the mechanical pressure test (p = 0.040). This represents a 2.7 (romifidine) and 3.4 times (detomidine) greater increase in thresholds using electrical current testing compared to the use of mechanical pressure testing. This study demonstrates the analgesic potential of alpha2-agonists in the horse for somatic pain and that they can have quantitatively different antinociceptive effects according to the antinociceptive test used.

  8. Digital music exposure reliably induces temporary threshold shift in normal-hearing human subjects.

    PubMed

    Le Prell, Colleen G; Dell, Shawna; Hensley, Brittany; Hall, James W; Campbell, Kathleen C M; Antonelli, Patrick J; Green, Glenn E; Miller, James M; Guire, Kenneth

    2012-01-01

    One of the challenges for evaluating new otoprotective agents for potential benefit in human populations is the availability of an established clinical paradigm with real-world relevance. These studies were explicitly designed to develop a real-world digital music exposure that reliably induces temporary threshold shift (TTS) in normal-hearing human subjects. Thirty-three subjects participated in studies that measured effects of digital music player use on hearing. Subjects selected either rock or pop music, which was then presented at 93 to 95 (n = 10), 98 to 100 (n = 11), or 100 to 102 (n = 12) dBA in-ear exposure level for a period of 4 hr. Audiograms and distortion product otoacoustic emissions (DPOAEs) were measured before and after music exposure. Postmusic tests were initiated 15 min, 1 hr 15 min, 2 hr 15 min, and 3 hr 15 min after the exposure ended. Additional tests were conducted the following day and 1 week later. Changes in thresholds after the lowest-level exposure were difficult to distinguish from test-retest variability; however, TTS was reliably detected after higher levels of sound exposure. Changes in audiometric thresholds had a "notch" configuration, with the largest changes observed at 4 kHz (mean = 6.3 ± 3.9 dB; range = 0-14 dB). Recovery was largely complete within the first 4 hr postexposure, and all subjects showed complete recovery of both thresholds and DPOAE measures when tested 1 week postexposure. These data provide insight into the variability of TTS induced by music-player use in a healthy, normal-hearing, young adult population, with music playlist, level, and duration carefully controlled. These data confirm the likelihood of temporary changes in auditory function after digital music-player use. Such data are essential for the development of a human clinical trial protocol that provides a highly powered design for evaluating novel therapeutics in human clinical trials. Care must be taken to fully inform potential subjects in future TTS studies, including protective agent evaluations, that some noise exposures have resulted in neural degeneration in animal models, even when both audiometric thresholds and DPOAE levels returned to pre-exposure values.

  9. Avulsion threshold in a large Himalayan river: the case of the Kosi, India and Nepal

    NASA Astrophysics Data System (ADS)

    Sinha, R.; Kommula, S.

    2010-12-01

    Avulsion, the relatively rapid shift of a river to a new course on a lower part of a floodplain, is considered as a major fluvial hazard in large population centers such as the north Bihar plains, eastern India and the adjoining areas of Nepal. This region witnessed one of the most recent avulsions of the Kosi River on 18 August, 2008 when the river shifted by ~120 km eastward. This was perhaps one of the greatest avulsions in a large river in recent years triggered by the breach of the eastern afflux bund at Kusaha in Nepal at a location 12 km upstream of the Kosi barrage and affecting more than 3 million people in Nepal and north Bihar. The trigger for an avulsion largely depends upon the regional channel-floodplain slope relationships and the lowest elevation available in the region. Most of the available assessments of avulsion threshold have therefore been based on the examination of channel slopes- longitudinal and cross-sectional. However, planform dynamics in a sediment-charged river such as the Kosi also plays an important role in pushing the river towards threshold for avulsion. The present study has made use of SRTM DEM, temporal satellite images and maps to compute the avulsion threshold for a ~50 km long reach of the Kosi river after incorporating planform dynamics in a GIS environment. Flow accumulation paths generated from the SRTM data match closely with the zones of high avulsion threshold. Not just that the Kusaha plots in a high avulsion threshold zone, we also identify several critical points where breach (avulsion) can occur in near future. This study assumes global significance keeping in view the most recent flooding in the Indus River in Pakistan. Like the Kusaha breach in Kosi in August 2008, the Indus flood trauma started with the breach of the eastern marginal embankment in the upstream of Taunsa barrage and was apparently triggered by rise of bed level due to excessive sediment load. The mega avulsion of the Kosi on 18th August 2008 which occurred due to a breach in the eastern embankment at Kusaha, Nepal

  10. Identifying failure in a tree network of a parallel computer

    DOEpatents

    Archer, Charles J.; Pinnow, Kurt W.; Wallenfelt, Brian P.

    2010-08-24

    Methods, parallel computers, and products are provided for identifying failure in a tree network of a parallel computer. The parallel computer includes one or more processing sets including an I/O node and a plurality of compute nodes. For each processing set embodiments include selecting a set of test compute nodes, the test compute nodes being a subset of the compute nodes of the processing set; measuring the performance of the I/O node of the processing set; measuring the performance of the selected set of test compute nodes; calculating a current test value in dependence upon the measured performance of the I/O node of the processing set, the measured performance of the set of test compute nodes, and a predetermined value for I/O node performance; and comparing the current test value with a predetermined tree performance threshold. If the current test value is below the predetermined tree performance threshold, embodiments include selecting another set of test compute nodes. If the current test value is not below the predetermined tree performance threshold, embodiments include selecting from the test compute nodes one or more potential problem nodes and testing individually potential problem nodes and links to potential problem nodes.

  11. Electrical leakage detection circuit

    DOEpatents

    Wild, Arthur

    2006-09-05

    A method is provided for detecting electrical leakage between a power supply and a frame of a vehicle or machine. The disclosed method includes coupling a first capacitor between a frame and a first terminal of a power supply for a predetermined period of time. The current flowing between the frame and the first capacitor is limited to a predetermined current limit. It is determined whether the voltage across the first capacitor exceeds a threshold voltage. A first output signal is provided when the voltage across the capacitor exceeds the threshold voltage.

  12. Temperature dependence of spontaneous emission in GaAs-AlGaAs quantum well lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blood, P.; Kucharska, A.I.; Foxon, C.T.

    1989-09-18

    Using quantum well laser devices with a window in the {ital p}-type contact, we have measured the relative change of spontaneous emission intensity at threshold with temperature for 58-A-wide GaAs wells. Over the range 250--340 K the data are in good agreement with the linear relation obtained from a gain-current calculation which includes transition broadening. This linear behavior contrasts with the stronger temperature dependence of the total measured threshold current of the same devices which includes nonradiative barrier recombination processes.

  13. Alcohol and ischaemic heart disease in middle aged British men.

    PubMed Central

    Shaper, A G; Phillips, A N; Pocock, S J; Walker, M

    1987-01-01

    The relation between alcohol intake and ischaemic heart disease was examined in a large scale prospective study of middle aged men drawn from general practices in 24 British towns. After an average follow up of 6.2 years 335 of the 7729 men had experienced a myocardial infarction (fatal or non-fatal) or sudden cardiac death. No significant relation was found between reported alcohol intake and the incidence of such events. Though the group of light daily drinkers had the lowest incidence of ischaemic heart disease events, it also contained the lowest proportion of current smokers, had the lowest mean blood pressure, had the lowest mean body mass index, and contained the lowest proportion of manual workers. These characteristics are more likely to account for the apparent protective effect of alcohol against ischaemic heart disease than a direct effect of alcohol. Compared with the effects of established risk factors alcohol seems to be quite unimportant in the development of ischaemic heart disease. PMID:3105714

  14. The DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure as a Screening Tool.

    PubMed

    Bastiaens, Leo; Galus, James

    2018-03-01

    The DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure was developed to aid clinicians with a dimensional assessment of psychopathology; however, this measure resembles a screening tool for several symptomatic domains. The objective of the current study was to examine the basic parameters of sensitivity, specificity, positive and negative predictive power of the measure as a screening tool. One hundred and fifty patients in a correctional community center filled out the measure prior to a psychiatric evaluation, including the Mini International Neuropsychiatric Interview screen. The above parameters were calculated for the domains of depression, mania, anxiety, and psychosis. The results showed that the sensitivity and positive predictive power of the studied domains was poor because of a high rate of false positive answers on the measure. However, when the lowest threshold on the Cross-Cutting Symptom Measure was used, the sensitivity of the anxiety and psychosis domains and the negative predictive values for mania, anxiety and psychosis were good. In conclusion, while it is foreseeable that some clinicians may use the DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure as a screening tool, it should not be relied on to identify positive findings. It functioned well in the negative prediction of mania, anxiety and psychosis symptoms.

  15. InP MOS capacitor and E-mode n-channel FET with ALD Al2O3-based high- k dielectric

    NASA Astrophysics Data System (ADS)

    Yen, Chih-Feng; Yeh, Min-Yen; Chong, Kwok-Keung; Hsu, Chun-Fa; Lee, Ming-Kwei

    2016-07-01

    The electrical characteristics of atomic-layer-deposited Al2O3/TiO2/Al2O3 on (NH4)2S-treated InP MOS capacitor and related MOSFET were studied. The electrical characteristics were improved from the reduction of native oxides and sulfur passivation on InP by (NH4)2S treatment. The high bandgap Al2O3 on TiO2 can reduce the thermionic emission, and the Al2O3 under TiO2 improves the interface-state density by self-cleaning. The high dielectric constant TiO2 is used to lower the equivalent oxide thickness. The leakage currents can reach 2.3 × 10-8 and 2.2 × 10-7 A/cm2 at ±2 MV/cm, respectively. The lowest interface-state density is 4.6 × 1011 cm-2 eV-1 with a low-frequency dispersion of 15 %. The fabricated enhancement-mode n-channel sulfur-treated InP MOSFET exhibits good electrical characteristics with a maximum transconductance of 146 mS/mm and effective mobility of 1760 cm2/V s. The subthreshold swing and threshold voltage are 117 mV/decade and 0.44 V, respectively.

  16. Temporal modulation transfer functions in cochlear implantees using a method that limits overall loudness cues

    PubMed Central

    Fraser, Matthew; McKay, Colette M.

    2012-01-01

    Temporal modulation transfer functions (TMTFs) were measured for six users of cochlear implants, using different carrier rates and levels. Unlike most previous studies investigating modulation detection, the experimental design limited potential effects of overall loudness cues. Psychometric functions (percent correct discrimination of modulated from unmodulated stimuli versus modulation depth) were obtained. For each modulation depth, each modulated stimulus was loudness balanced to the unmodulated reference stimulus, and level jitter was applied in the discrimination task. The loudness-balance data showed that the modulated stimuli were louder than the unmodulated reference stimuli with the same average current, thus confirming the need to limit loudness cues when measuring modulation detection. TMTFs measured in this way had a low-pass characteristic, with a cut-off frequency (at comfortably loud levels) similar to that for normal-hearing listeners. A reduction in level caused degradation in modulation detection efficiency and a lower-cut-off frequency (i.e. poorer temporal resolution). An increase in carrier rate also led to a degradation in modulation detection efficiency, but only at lower levels or higher modulation frequencies. When detection thresholds were expressed as a proportion of dynamic range, there was no effect of carrier rate for the lowest modulation frequency (50 Hz) at either level. PMID:22146425

  17. Evaluation of pesticide residue dynamics in Chinese cabbage, head cabbage and cauliflower.

    PubMed

    Kocourek, František; Stará, Jitka; Holý, Kamil; Horská, Tereza; Kocourek, Vladimír; Kováčová, Jana; Kohoutková, Jana; Suchanová, Marie; Hajšlová, Jana

    2017-06-01

    Pesticide residues from the time of application until harvest were analysed for 20, 17 and 18 active insecticidal and fungicidal substances in Chinese cabbage, head cabbage and cauliflower, respectively. In total, 40 mathematical models of residue degradation were developed using a first-order kinetic equation, and from these models it was possible to forecast the action pre-harvest interval for a given action threshold for low-residue production in Brassica vegetables as a percentage of the maximum residue level. Additionally, it was possible to establish an action pre-harvest interval based on an action threshold of 0.01 mg kg ‒1 for the production of Brassica vegetables for baby food. Among the evaluated commodities, the speed of residue degradation was highest in head cabbage, medium in Chinese cabbage and lowest in cauliflower. The half-lives of pesticide in various vegetables were also determined: they ranged from 1.55 to 5.25 days in Chinese cabbage, from 0.47 to 6.54 days in head cabbage and from 1.88 to 7.22 days in cauliflower.

  18. Amino acid changes within the E protein hinge region that affect dengue virus type 2 infectivity and fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butrapet, Siritorn; Childers, Thomas; Moss, Kelley J.

    Fifteen mutant dengue viruses were engineered and used to identify AAs in the molecular hinge of the envelope protein that are critical to viral infection. Substitutions at Q52, A54, or E133 reduced infectivity in mammalian cells and altered the pH threshold of fusion. Mutations at F193, G266, I270, or G281 affected viral replication in mammalian and mosquito cells, but only I270W had reduced fusion activity. T280Y affected the pH threshold for fusion and reduced replication in C6/36 cells. Three different mutations at L135 were lethal in mammalian cells. Among them, L135G abrogated fusion and reduced replication in C6/36 cells, butmore » only slightly reduced the mosquito infection rate. Conversely, L135W replicated well in C6/36 cells, but had the lowest mosquito infection rate. Possible interactions between hinge residues 52 and 277, or among 53, 135, 170, 186, 265, and 276 required for hinge function were discovered by sequence analysis to identify compensatory mutations.« less

  19. Return volatility interval analysis of stock indexes during a financial crash

    NASA Astrophysics Data System (ADS)

    Li, Wei-Shen; Liaw, Sy-Sang

    2015-09-01

    We investigate the interval between return volatilities above a certain threshold q for 10 countries data sets during the 2008/2009 global financial crisis, and divide these data into several stages according to stock price tendencies: plunging stage (stage 1), fluctuating or rebounding stage (stage 2) and soaring stage (stage 3). For different thresholds q, the cumulative distribution function always satisfies a power law tail distribution. We find the absolute value of the power-law exponent is lowest in stage 1 for various types of markets, and increases monotonically from stage 1 to stage 3 in emerging markets. The fractal dimension properties of the return volatility interval series provide some surprising results. We find that developed markets have strong persistence and transform to weaker correlation in the plunging and soaring stages. In contrast, emerging markets fail to exhibit such a transformation, but rather show a constant-correlation behavior with the recurrence of extreme return volatility in corresponding stages during a crash. We believe this long-memory property found in recurrence-interval series, especially for developed markets, plays an important role in volatility clustering.

  20. Aging and the discrimination of 3-D shape from motion and binocular disparity.

    PubMed

    Norman, J Farley; Holmin, Jessica S; Beers, Amanda M; Cheeseman, Jacob R; Ronning, Cecilia; Stethen, Angela G; Frost, Adam L

    2012-10-01

    Two experiments evaluated the ability of younger and older adults to visually discriminate 3-D shape as a function of surface coherence. The coherence was manipulated by embedding the 3-D surfaces in volumetric noise (e.g., for a 55 % coherent surface, 55 % of the stimulus points fell on a 3-D surface, while 45 % of the points occupied random locations within the same volume of space). The 3-D surfaces were defined by static binocular disparity, dynamic binocular disparity, and motion. The results of both experiments demonstrated significant effects of age: Older adults required more coherence (tolerated volumetric noise less) for reliable shape discrimination than did younger adults. Motion-defined and static-binocular-disparity-defined surfaces resulted in similar coherence thresholds. However, performance for dynamic-binocular-disparity-defined surfaces was superior (i.e., the observers' surface coherence thresholds were lowest for these stimuli). The results of both experiments showed that younger and older adults possess considerable tolerance to the disrupting effects of volumetric noise; the observers could reliably discriminate 3-D surface shape even when 45 % of the stimulus points (or more) constituted noise.

  1. SU(6) GUT breaking on a projective plane

    NASA Astrophysics Data System (ADS)

    Anandakrishnan, Archana; Raby, Stuart

    2013-03-01

    We consider a 6-dimensional supersymmetric SU(6) gauge theory and compactify two extra-dimensions on a multiply-connected manifold with non-trivial topology. The SU(6) is broken down to the Standard Model gauge groups in two steps by an orbifold projection, followed by a Wilson line. The Higgs doublets of the low energy electroweak theory come from a chiral adjoint of SU(6). We thus have gauge-Higgs unification. The three families of the Standard Model can either be located in the 6D bulk or at 4D N=1 supersymmetric fixed points. We calculate the Kaluza-Klein spectrum of states arising as a result of the orbifolding. We also calculate the threshold corrections to the coupling constants due to this tower of states at the lowest compactification scale. We study the regions of parameter space of this model where the threshold corrections are consistent with low energy physics. We find that the couplings receive only logarithmic corrections at all scales. This feature can be attributed to the large N=2 6D SUSY of the underlying model.

  2. Method and apparatus for clockless analog-to-digital conversion and peak detection

    DOEpatents

    DeGeronimo, Gianluigi

    2007-03-06

    An apparatus and method for analog-to-digital conversion and peak detection includes at least one stage, which includes a first switch, second switch, current source or capacitor, and discriminator. The discriminator changes state in response to a current or charge associated with the input signal exceeding a threshold, thereby indicating whether the current or charge associated with the input signal is greater than the threshold. The input signal includes a peak or a charge, and the converter includes a peak or charge detect mode in which a state of the switch is retained in response to a decrease in the current or charge associated with the input signal. The state of the switch represents at least a portion of a value of the peak or of the charge.

  3. Sub-100 fJ and sub-nanosecond thermally driven threshold switching in niobium oxide crosspoint nanodevices.

    PubMed

    Pickett, Matthew D; Williams, R Stanley

    2012-06-01

    We built and measured the dynamical current versus time behavior of nanoscale niobium oxide crosspoint devices which exhibited threshold switching (current-controlled negative differential resistance). The switching speeds of 110 × 110 nm(2) devices were found to be Δt(ON) = 700 ps and Δt(OFF) = 2:3 ns while the switching energies were of the order of 100 fJ. We derived a new dynamical model based on the Joule heating rate of a thermally driven insulator-to-metal phase transition that accurately reproduced the experimental results, and employed the model to estimate the switching time and energy scaling behavior of such devices down to the 10 nm scale. These results indicate that threshold switches could be of practical interest in hybrid CMOS nanoelectronic circuits.

  4. A theoretical approach to study the optical sensitivity of a MESFET

    NASA Astrophysics Data System (ADS)

    Dutta, Sutanu

    2018-05-01

    A theoretical model to study the optical sensitivity of a metal-semiconductor field effect transistor has been proposed for a relatively high drain field. An analytical expression of drain current of the device has been derived for a MESFET under optical illumination considering field dependent mobility of electrons across the channel. The variation of drain current with and without optical illumination has been studied with drain and gate voltages. The optical sensitivity of the drain current has been studied for different biasing conditions and gate lengths. In addition, the shift in threshold voltage of a MESFET under optical illumination is determined and optical sensitivity of the device in terms of its threshold voltage has been studied.

  5. Effects of arc current on the life in burner rig thermal cycling of plasma sprayed ZrOsub2-Ysub2Osub3

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Mcdonald, G.

    1982-01-01

    An analysis of thermal cycle life data for four sets of eight thermal barrier coated specimens representing arc currents (plasma gun power) of 525, 600, 800, or 950 amps is presented. The ZrO2-8Y2O3/NiCrAlY plasma spray coated Rene 41 rods were thermal cycled to 1040 C in a Mach 0.3-Jet A/air burner flame. The experimental results indicate the existance of a minimum or threshold power level which coating life expectancy is less than 500 cycles. Above the threshold power level, coating life expectancy more than doubles and increases with arc current.

  6. Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

    NASA Technical Reports Server (NTRS)

    Ebert, D.; Macias, B.; Sargsyan, A.; Garcia, K.; Stenger, M.; Kemp, D.; Hargens, A.; Johnston, S.

    2017-01-01

    Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure.

  7. Effects of arc current on the life in burner rig thermal cycling of plasma sprayed ZrOsub2-Ysub2Osub3

    NASA Astrophysics Data System (ADS)

    Hendricks, R. C.; McDonald, G.

    1982-02-01

    An analysis of thermal cycle life data for four sets of eight thermal barrier coated specimens representing arc currents (plasma gun power) of 525, 600, 800, or 950 amps is presented. The ZrO2-8Y2O3/NiCrAlY plasma spray coated Rene 41 rods were thermal cycled to 1040 C in a Mach 0.3-Jet A/air burner flame. The experimental results indicate the existance of a minimum or threshold power level which coating life expectancy is less than 500 cycles. Above the threshold power level, coating life expectancy more than doubles and increases with arc current.

  8. Effects of cement alkalinity, exposure conditions and steel-concrete interface on the time-to-corrosion and chloride threshold for reinforcing steel in concrete

    NASA Astrophysics Data System (ADS)

    Nam, Jingak

    Effects of (1) cement alkalinity (low, normal and high), (2) exposure conditions (RH and temperature), (3) rebar surface condition (as-received versus cleaned) and (4) density and distribution of air voids at the steel-concrete interface on the chloride threshold and time-to-corrosion for reinforcing steel in concrete have been studied. Also, experiments were performed to evaluate effects of RH and temperature on the diffusion of chloride in concrete and develop a method for ex-situ pH measurement of concrete pore water. Once specimens were fabricated and exposed to a corrosive chloride solution, various experimental techniques were employed to determine time-to-corrosion, chloride threshold, diffusion coefficient and void density along the rebar trace as well as pore water pH. Based upon the resultant data, several findings related to the above parameters have been obtained as summarized below. First, time for the corrosion initiation was longest for G109 concrete specimens with high alkalinity cement (HA). Also, chloride threshold increased with increasing time-to-corrosion and cement alkalinity. Consequently, the HA specimens exhibited the highest chloride threshold compared to low and normal alkalinity ones. Second, high temperature and temperature variations reduced time-to-corrosion of reinforcing steel in concrete since chloride diffusion was accelerated at higher temperature and possibly by temperature variations. The lowest chloride threshold values were found for outdoor exposed specimens suggesting that variation of RH or temperature (or both) facilitated rapid chloride diffusion. Third, an elevated time-to-corrosion and chloride threshold values were found for the wire brushed steel specimens compared to as-received ones. The higher ratio of [OH-]/[Fe n+] on the wire brushed steel surface compared to that of as-received case can be the possible cause because the higher ratio of this parameter enables the formation of a more protective passive film on the rebar. Fourth, voids at the steel-concrete interface facilitated passive film breakdown and onset of localized corrosion. This tendency for corrosion initiation increased in proportion to void size irrespective of specimen type. Also, [Cl -]th decreased with increasing void diameter. In addition, new ex-situ leaching method for determining concrete pore water alkalinity was developed.

  9. Low threshold interband cascade lasers operating above room temperature

    NASA Technical Reports Server (NTRS)

    Hill, C. J.; Yang, B.; Yang, R. Q.

    2003-01-01

    Mid-IR type-II interband cascade lasers were demonstrated in pulsed mode at temperatures up to 325 K and in continuous mode up to 200 K. At 80 K, the threshold current density was 8.9 A/cm2 and a cw outpout power of 140 mW/facet was obtained.

  10. Salty Taste Acuity Is Affected by the Joint Action of αENaC A663T Gene Polymorphism and Available Zinc Intake in Young Women

    PubMed Central

    Noh, Hwayoung; Paik, Hee-Young; Kim, Jihye; Chung, Jayong

    2013-01-01

    Salty taste perception affects salt intake, of which excess amounts is a major public health concern. Gene polymorphisms in salty taste receptors, zinc status and their interaction may affect salty taste perception. In this study, we examined the relationships among the α-epithelial sodium channel (αENaC) A663T genotype, zinc intake, and salty taste perception including salty taste acuity and preference in healthy young adults. The αENaC A663T genotype was determined by the PCR-restriction fragment length polymorphism in 207 adults. Zinc intake was examined by one 24-h recall and a two-day dietary record. Salty taste acuity and preference were determined by measuring the salty taste recognition threshold and the preferred salinity of beansprout soup, respectively. Men had significantly higher thresholds and preferences for salty taste than women did (p < 0.05). In women, the salty taste threshold was significantly lower in the highest tertile of available zinc intake than in the lowest tertile (12.2 mM and 17.6 mM, respectively, p = 0.02). Interestingly, a significant inverse association between available zinc intake and salty taste threshold was found only in women with αENaC AA homozygotes (β = −0.833, p = 0.02), and no such association was found in T663 allele carriers. The salty taste preference was not associated with the αENaC A663T genotype or available zinc intake in either sex. In conclusion, our data suggest that gene-nutrient interactions between the αENaC A663T genotype and available zinc intake play a role in determining the salty taste acuity in young women. PMID:24317554

  11. The role of thermal physiology in recent declines of birds in a biodiversity hotspot.

    PubMed

    Milne, Robyn; Cunningham, Susan J; Lee, Alan T K; Smit, Ben

    2015-01-01

    We investigated whether observed avian range contractions and population declines in the Fynbos biome of South Africa were mechanistically linked to recent climate warming. We aimed to determine whether there were correlations between preferred temperature envelope, or changes in temperature within species' ranges, and recent changes in range and population size, for 12 Fynbos-resident bird species, including six that are endemic to the biome. We then measured the physiological responses of each species at air temperatures ranging from 24 to 42°C to determine whether physiological thermal thresholds could provide a mechanistic explanation for observed population trends. Our data show that Fynbos-endemic species occupying the coolest regions experienced the greatest recent reductions in range and population size (>30% range reduction between 1991 and the present). In addition, species experiencing the largest increases in air temperature within their ranges showed the greatest declines. However, evidence for a physiological mechanistic link between warming and population declines was equivocal, with only the larger species showing low thermal thresholds for their body mass, compared with other birds globally. In addition, some species appear more vulnerable than others to air temperatures in their ranges above physiological thermal thresholds. Of these, the high-altitude specialist Cape rockjumper (Chaetops frenatus) seems most at risk from climate warming. This species showed: (i) the lowest threshold for increasing evaporative water loss at high temperatures; and (ii) population declines specifically in those regions of its range recording significant warming trends. Our findings suggest that caution must be taken when attributing causality explicitly to thermal stress, even when population trends are clearly correlated with rates of warming. Studies explicitly investigating the mechanisms underlying such correlations will be key to appropriate conservation planning.

  12. Validation of quantitative light-induced fluorescence-digital (QLF-D) for the detection of approximal caries in vitro.

    PubMed

    Ko, Hae-Youn; Kang, Si-Mook; Kim, Hee Eun; Kwon, Ho-Keun; Kim, Baek-Il

    2015-05-01

    Detection of approximal caries lesions can be difficult due to their anatomical position. This study aimed to assess the ability of the quantitative light-induced fluorescence-digital (QLF-D) in detecting approximal caries, and to compare the performance with those of the International Caries Detection and Assessment System II (ICDAS II) and digital radiography (DR). Extracted permanent teeth (n=100) were selected and mounted in pairs. The simulation pairs were assessed by one calibrated dentist using each detection method. After all the examinations, the teeth (n=95) were sectioned and examined histologically as gold standard. The modalities were compared in terms of sensitivity, specificity, areas under receiver operating characteristic curves (AUROC) for enamel (D1) and dentine (D3) levels. The intra-examiner reliability was assessed for all modalities. At D1 threshold, the ICDAS II presented the highest sensitivity (0.80) while the DR showed the highest specificity (0.89); however, the methods with the greatest AUC values at D1 threshold were DR and QLF-D (0.80 and 0.80 respectively). At D3 threshold, the methods with the highest sensitivity were ICDAS II and QLF-D (0.64 and 0.64 respectively) while the method with the lowest sensitivity was DR (0.50). However, with regard to the AUC values at D3 threshold, the QLF-D presented the highest value (0.76). All modalities showed to have excellent intra-examiner reliability. The newly developed QLF-D was not only able to detect proximal caries, but also showed to have comparable performance to the visual inspection and radiography in detecting proximal caries. QLF-D has the potential to be a useful detection method for proximal caries. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Determination of irritant threshold concentrations of multiple tree, grass, weed and mould allergens for intradermal testing of horses residing in the southern USA.

    PubMed

    Lane, Martha J; Pucheu-Haston, Cherie M; Kearney, Michael T; Woodward, Michelle

    2017-12-01

    Appropriate allergen threshold concentrations (TCs) for intradermal testing (IDT) have not been established in horses for many pollen and mould allergens. To determine the TCs in non-allergic horses and describe the frequency of late phase reactions for 26 allergens, including trees, grasses, weeds and moulds in horses residing in the southern Unites States. Twenty four clinically normal horses in the southern United States. Threshold concentrations for different allergens were determined using IDT subjective measurements at 30 minutes. Delayed reactions were evaluated at 4 and 24 h. Threshold concentrations (all PNU/mL) were established for eight tree allergens (black willow 1,000, box elder 1,000, live oak 1,000, pecan 2,000, white ash 4,000, red oak 4,000, red mulberry 2,000 and green ash 2,000); two grass allergens (Johnson grass 250 PNU/mL and Kentucky blue grass 500 PNU/mL); two weeds (carelessweed 1,000 PNU/mL, great ragweed 500 PNU/mL) and one mould (Curvularia 8,000 PNU/mL). The TC was not determined due to excessive reactivity at the lowest concentration tested (1,000 PNU/mL) for bahia and perennial rye grass. Eleven other allergens did not meet the criteria to establish a TC when evaluated at 30 min due to lack of positive reactions. Multiple allergens caused positive reactions in ≥10% of horses at 4 h. Reactions at 24 h were rare with the exception of one horse. This study identified intradermal TC for multiple pollen and mould allergens in horses. These values may prove useful for optimizing allergen concentrations for IDT of allergic horses. © 2017 ESVD and ACVD.

  14. The role of thermal physiology in recent declines of birds in a biodiversity hotspot

    PubMed Central

    Milne, Robyn; Cunningham, Susan J; Lee, Alan T K

    2015-01-01

    Abstract We investigated whether observed avian range contractions and population declines in the Fynbos biome of South Africa were mechanistically linked to recent climate warming. We aimed to determine whether there were correlations between preferred temperature envelope, or changes in temperature within species' ranges, and recent changes in range and population size, for 12 Fynbos-resident bird species, including six that are endemic to the biome. We then measured the physiological responses of each species at air temperatures ranging from 24 to 42°C to determine whether physiological thermal thresholds could provide a mechanistic explanation for observed population trends. Our data show that Fynbos-endemic species occupying the coolest regions experienced the greatest recent reductions in range and population size (>30% range reduction between 1991 and the present). In addition, species experiencing the largest increases in air temperature within their ranges showed the greatest declines. However, evidence for a physiological mechanistic link between warming and population declines was equivocal, with only the larger species showing low thermal thresholds for their body mass, compared with other birds globally. In addition, some species appear more vulnerable than others to air temperatures in their ranges above physiological thermal thresholds. Of these, the high-altitude specialist Cape rockjumper (Chaetops frenatus) seems most at risk from climate warming. This species showed: (i) the lowest threshold for increasing evaporative water loss at high temperatures; and (ii) population declines specifically in those regions of its range recording significant warming trends. Our findings suggest that caution must be taken when attributing causality explicitly to thermal stress, even when population trends are clearly correlated with rates of warming. Studies explicitly investigating the mechanisms underlying such correlations will be key to appropriate conservation planning. PMID:27293732

  15. Impact of co-administration of oxycodone and smoked cannabis on analgesia and abuse liability.

    PubMed

    Cooper, Ziva D; Bedi, Gillinder; Ramesh, Divya; Balter, Rebecca; Comer, Sandra D; Haney, Margaret

    2018-02-05

    Cannabinoids combined with opioids produce synergistic antinociceptive effects, decreasing the lowest effective antinociceptive opioid dose (i.e., opioid-sparing effects) in laboratory animals. Although pain patients report greater analgesia when cannabis is used with opioids, no placebo-controlled studies have assessed the direct effects of opioids combined with cannabis in humans or the impact of the combination on abuse liability. This double-blind, placebo-controlled, within-subject study determined if cannabis enhances the analgesic effects of low dose oxycodone using a validated experimental model of pain and its effects on abuse liability. Healthy cannabis smokers (N = 18) were administered oxycodone (0, 2.5, and 5.0 mg, PO) with smoked cannabis (0.0, 5.6% Δ 9 tetrahydrocannabinol [THC]) and analgesia was assessed using the Cold-Pressor Test (CPT). Participants immersed their hand in cold water (4 °C); times to report pain (pain threshold) and withdraw the hand from the water (pain tolerance) were recorded. Abuse-related effects were measured and effects of oxycodone on cannabis self-administration were determined. Alone, 5.0 mg oxycodone increased pain threshold and tolerance (p ≤ 0.05). Although active cannabis and 2.5 mg oxycodone alone failed to elicit analgesia, combined they increased pain threshold and tolerance (p ≤ 0.05). Oxycodone did not increase subjective ratings associated with cannabis abuse, nor did it increase cannabis self-administration. However, the combination of 2.5 mg oxycodone and active cannabis produced small, yet significant, increases in oxycodone abuse liability (p ≤ 0.05). Cannabis enhances the analgesic effects of sub-threshold oxycodone, suggesting synergy, without increases in cannabis's abuse liability. These findings support future research into the therapeutic use of opioid-cannabinoid combinations for pain.

  16. Speech-in-Noise Tests and Supra-threshold Auditory Evoked Potentials as Metrics for Noise Damage and Clinical Trial Outcome Measures.

    PubMed

    Le Prell, Colleen G; Brungart, Douglas S

    2016-09-01

    In humans, the accepted clinical standards for detecting hearing loss are the behavioral audiogram, based on the absolute detection threshold of pure-tones, and the threshold auditory brainstem response (ABR). The audiogram and the threshold ABR are reliable and sensitive measures of hearing thresholds in human listeners. However, recent results from noise-exposed animals demonstrate that noise exposure can cause substantial neurodegeneration in the peripheral auditory system without degrading pure-tone audiometric thresholds. It has been suggested that clinical measures of auditory performance conducted with stimuli presented above the detection threshold may be more sensitive than the behavioral audiogram in detecting early-stage noise-induced hearing loss in listeners with audiometric thresholds within normal limits. Supra-threshold speech-in-noise testing and supra-threshold ABR responses are reviewed here, given that they may be useful supplements to the behavioral audiogram for assessment of possible neurodegeneration in noise-exposed listeners. Supra-threshold tests may be useful for assessing the effects of noise on the human inner ear, and the effectiveness of interventions designed to prevent noise trauma. The current state of the science does not necessarily allow us to define a single set of best practice protocols. Nonetheless, we encourage investigators to incorporate these metrics into test batteries when feasible, with an effort to standardize procedures to the greatest extent possible as new reports emerge.

  17. A contraction-related component of slow inward current in dog ventricular muscle and its relation to Na(+)-Ca2+ exchange.

    PubMed Central

    Simurda, J; Simurdová, M; Bravený, P; Sumbera, J

    1992-01-01

    1. The slow inward current component related to contraction (Isic) was studied in voltage clamp experiments on canine ventricular trabeculae at 30 degrees C with the aims of (a) estimating its relation to electrogenic Na(+)-Ca2+ exchange and (b) comparing it with similar currents as reported in cardiac myocytes. 2. Isic may be recorded under conditions of augmented contractility in response to depolarizing pulses below the threshold of the classic slow inward current (presumably mediated by L-type Ca2+ channels). In responses to identical depolarizing clamp pulses the peak value of Isic is directly related to the amplitude of contraction (Fmax). Isic peaks about 60 ms after the onset of depolarization and declines with a half-time of about 110 ms. 3. The voltage threshold of Isic activation is the same as the threshold of contraction. The positive inotropic clamp preconditions shift both thresholds to more negative values of membrane voltage, i.e. below the threshold of the classic slow inward current. 4. Isic may also be recorded as a slowly decaying inwardly directed current 'tail' after depolarizing pulses. In this representation the peak value of Isic changes with duration of the depolarizing pulses, again in parallel with Fmax. In response to pulses shorter than 100 ms both variables increase with depolarization time. If initial conditions remain constant, further prolongation of the pulse does not significantly influence either one (tail currents follow a common envelope). 5. Isic differs from classic slow inward current by: (a) its direct relation to contraction, (b) the slower decay of the current tail on repolarization, (c) slower restitution corresponding to the mechanical restitution, (d) its relative insensitivity to Ca(2+)-blocking agents (the decrease of Isic is secondary to the negative inotropic of Ca(2+)-blocking agents (the decrease of Isic is secondary to the negative inotropic effect) and (e) its disappearance after Sr2+ substitution for Ca2+. 6. The manifestations of Isic in multicellular preparations do not differ significantly from those reported in isolated myocytes (in contrast to calcium current). 7. The analysis of the correlation between Isic and Fmax transients during trains of identical test depolarizing pulses at variable extra- and intracellular ionic concentrations (changes of [Ca2+]o, 50% Li+ substitution for Na+, strophanthidin) indicate that the observed effects conform to the predictions based on a quantitative model of Na(+)-Ca2+ exchange. 8. It is concluded that Isic is activated by a transient increase of [Ca2+]i, in consequence of the release from the reticular stores.(ABSTRACT TRUNCATED AT 400 WORDS) PMID:1293284

  18. Prevention of Ca(2+)-mediated action potentials in GABAergic local circuit neurones of rat thalamus by a transient K+ current.

    PubMed Central

    Pape, H C; Budde, T; Mager, R; Kisvárday, Z F

    1994-01-01

    1. Neurones enzymatically dissociated from the rat dorsal lateral geniculate nucleus (LGN) were identified as GABAergic local circuit interneurones and geniculocortical relay cells, based upon quantitative analysis of soma profiles, immunohistochemical detection of GABA or glutamic acid decarboxylase, and basic electrogenic behaviour. 2. During whole-cell current-clamp recording, isolated LGN neurones generated firing patterns resembling those in intact tissue, with the most striking difference relating to the presence in relay cells of a Ca2+ action potential with a low threshold of activation, capable of triggering fast spikes, and the absence of a regenerative Ca2+ response with a low threshold of activation in local circuit cells. 3. Whole-cell voltage-clamp experiments demonstrated that both classes of LGN neurones possess at least two voltage-dependent membrane currents which operate in a range of membrane potentials negative to the threshold for generation of Na(+)-K(+)-mediated spikes: the T-type Ca2+ current (IT) and an A-type K+ current (IA). Taking into account the differences in membrane surface area, the average size of IT was similar in the two types of neurones, and interneurones possessed a slightly larger A-conductance. 4. In local circuit neurones, the ranges of steady-state inactivation and activation of IT and IA were largely overlapping (VH = 81.1 vs. -82.8 mV), both currents activated at around -70 mV, and they rapidly increased in amplitude with further depolarization. In relay cells, the inactivation curve of IT was negatively shifted along the voltage axis by about 20 mV compared with that of IA (Vh = -86.1 vs. -69.2 mV), and the activation threshold for IT (at -80 mV) was 20 mV more negative than that for IA. In interneurones, the activation range of IT was shifted to values more positive than that in relay cells (Vh = -54.9 vs. -64.5 mV), whereas the activation range of IA was more negative (Vh = -25.2 vs. -14.5 mV). 5. Under whole-cell voltage-clamp conditions that allowed the combined activation of Ca2+ and K+ currents, depolarizing voltage steps from -110 mV evoked inward currents resembling IT in relay cells and small outward currents indicative of IA in local circuit neurones. After blockade of IA with 4-aminopyridine (4-AP), the same pulse protocol produced IT in both types of neurones. Under current clamp, 4-AP unmasked a regenerative membrane depolarization with a low threshold of activation capable of triggering fast spikes in local circuit neurones.(ABSTRACT TRUNCATED AT 400 WORDS) Images Figure 1 PMID:7965855

  19. Is the tier-1 effect assessment for herbicides protective for aquatic algae and vascular plant communities?

    PubMed

    van Wijngaarden, René P A; Arts, Gertie H P

    2018-01-01

    In the aquatic tier-1 effect assessment for plant protection products with an herbicidal mode of action in Europe, it is usually algae and/or vascular plants that determine the environmental risks. This tier includes tests with at least 2 algae and 1 macrophyte (Lemna). Although such tests are considered to be of a chronic nature (based on the duration of the test in relation to the life cycle of the organism), the measurement endpoints derived from the laboratory tests with plants (including algae) and used in the first-tier effect assessment for herbicides are acute effect concentrations affecting 50% of the test organisms (EC50 values) and not no-observed-effect concentrations (NOECs) or effect concentrations affecting 10% of the test organisms (EC10) values. Other European legislative frameworks (e.g., the Water Framework Directive) use EC10 values. The present study contributes to a validation of the tiered herbicide risk assessment approach by comparing the standard first-tier effect assessment with results of microcosm and mesocosm studies. We evaluated EC50 and EC10 values for standard test algae and macrophytes based on either the growth rate endpoint (E r C50) or the lowest available endpoint for growth rate or biomass/yield (E r /E y C50). These values were compared with the regulatory acceptable concentrations for the threshold option as derived from microcosm and mesocosm studies. For these studies, protection is maintained if growth rate is taken as the regulatory endpoint instead of the lowest value of either growth rate or biomass/yield in conjunction with the standard assessment factor of 10. Based on a limited data set of 14 herbicides, we did not identify a need to change the current practice. Environ Toxicol Chem 2018;37:175-183. © 2017 SETAC. © 2017 SETAC.

  20. Selective control of cortical axonal spikes by a slowly inactivating K+ current

    PubMed Central

    Shu, Yousheng; Yu, Yuguo; Yang, Jing; McCormick, David A.

    2007-01-01

    Neurons are flexible electrophysiological entities in which the distribution and properties of ionic channels control their behaviors. Through simultaneous somatic and axonal whole-cell recording of layer 5 pyramidal cells, we demonstrate a remarkable differential expression of slowly inactivating K+ currents. Depolarizing the axon, but not the soma, rapidly activated a low-threshold, slowly inactivating, outward current that was potently blocked by low doses of 4-aminopyridine, α-dendrotoxin, and rTityustoxin-Kα. Block of this slowly inactivating current caused a large increase in spike duration in the axon but only a small increase in the soma and could result in distal axons generating repetitive discharge in response to local current injection. Importantly, this current was also responsible for slow changes in the axonal spike duration that are observed after somatic membrane potential change. These data indicate that low-threshold, slowly inactivating K+ currents, containing Kv1.2 α subunits, play a key role in the flexible properties of intracortical axons and may contribute significantly to intracortical processing. PMID:17581873

  1. Revealed willingness-to-pay versus standard cost-effectiveness thresholds: Evidence from the South African HIV Investment Case.

    PubMed

    Meyer-Rath, Gesine; van Rensburg, Craig; Larson, Bruce; Jamieson, Lise; Rosen, Sydney

    2017-01-01

    The use of cost-effectiveness thresholds based on a country's income per capita has been criticized for not being relevant to decision making, in particular in middle-income countries such as South Africa. The recent South African HIV Investment Case produced an alternative cost-effectiveness threshold for HIV prevention and treatment interventions based on estimates of life years saved and the country's committed HIV budget. We analysed the optimal mix of HIV interventions over a baseline of the current HIV programme under the committed HIV budget for 2016-2018. We calculated the incremental cost-effectiveness ratio (ICER) as cost per life-year saved (LYS) of 16 HIV prevention and treatment interventions over 20 years (2016-2035). We iteratively evaluated the most cost effective option (defined by an intervention and its coverage) over a rolling baseline to which the more cost effective options had already been added, thereby allowing for diminishing marginal returns to interventions. We constrained the list of interventions to those whose combined cost was affordable under the current HIV budget. Costs are presented from the government perspective, unadjusted for inflation and undiscounted, in 2016 USD. The current HIV budget of about $1.6 billion per year was sufficient to pay for the expansion of condom availability, medical male circumcision, universal treatment, and infant testing at 6 weeks to maximum coverage levels, while also implementing a social and behavior change mass media campaign with a message geared at increasing testing uptake and reducing the number of sexual partners. The combined ICER of this package of services was $547/ LYS. The ICER of the next intervention that was above the affordability threshold was $872/LYS. The results of the South African HIV Investment Case point to an HIV cost-effectiveness threshold based on affordability under the current budget of $547-872 per life year saved, a small fraction of the country's GDP per capita of about $6,000.

  2. Thresholds in chemical respiratory sensitisation.

    PubMed

    Cochrane, Stella A; Arts, Josje H E; Ehnes, Colin; Hindle, Stuart; Hollnagel, Heli M; Poole, Alan; Suto, Hidenori; Kimber, Ian

    2015-07-03

    There is a continuing interest in determining whether it is possible to identify thresholds for chemical allergy. Here allergic sensitisation of the respiratory tract by chemicals is considered in this context. This is an important occupational health problem, being associated with rhinitis and asthma, and in addition provides toxicologists and risk assessors with a number of challenges. In common with all forms of allergic disease chemical respiratory allergy develops in two phases. In the first (induction) phase exposure to a chemical allergen (by an appropriate route of exposure) causes immunological priming and sensitisation of the respiratory tract. The second (elicitation) phase is triggered if a sensitised subject is exposed subsequently to the same chemical allergen via inhalation. A secondary immune response will be provoked in the respiratory tract resulting in inflammation and the signs and symptoms of a respiratory hypersensitivity reaction. In this article attention has focused on the identification of threshold values during the acquisition of sensitisation. Current mechanistic understanding of allergy is such that it can be assumed that the development of sensitisation (and also the elicitation of an allergic reaction) is a threshold phenomenon; there will be levels of exposure below which sensitisation will not be acquired. That is, all immune responses, including allergic sensitisation, have threshold requirement for the availability of antigen/allergen, below which a response will fail to develop. The issue addressed here is whether there are methods available or clinical/epidemiological data that permit the identification of such thresholds. This document reviews briefly relevant human studies of occupational asthma, and experimental models that have been developed (or are being developed) for the identification and characterisation of chemical respiratory allergens. The main conclusion drawn is that although there is evidence that the acquisition of sensitisation to chemical respiratory allergens is a dose-related phenomenon, and that thresholds exist, it is frequently difficult to define accurate numerical values for threshold exposure levels. Nevertheless, based on occupational exposure data it may sometimes be possible to derive levels of exposure in the workplace, which are safe. An additional observation is the lack currently of suitable experimental methods for both routine hazard characterisation and the measurement of thresholds, and that such methods are still some way off. Given the current trajectory of toxicology, and the move towards the use of non-animal in vitro and/or in silico) methods, there is a need to consider the development of alternative approaches for the identification and characterisation of respiratory sensitisation hazards, and for risk assessment. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. A new evaluation method of electron optical performance of high beam current probe forming systems.

    PubMed

    Fujita, Shin; Shimoyama, Hiroshi

    2005-10-01

    A new numerical simulation method is presented for the electron optical property analysis of probe forming systems with point cathode guns such as cold field emitters and the Schottky emitters. It has long been recognized that the gun aberrations are important parameters to be considered since the intrinsically high brightness of the point cathode gun is reduced due to its spherical aberration. The simulation method can evaluate the 'threshold beam current I(th)' above which the apparent brightness starts to decrease from the intrinsic value. It is found that the threshold depends on the 'electron gun focal length' as well as on the spherical aberration of the gun. Formulas are presented to estimate the brightness reduction as a function of the beam current. The gun brightness reduction must be included when the probe property (the relation between the beam current l(b) and the probe size on the sample, d) of the entire electron optical column is evaluated. Formulas that explicitly consider the gun aberrations into account are presented. It is shown that the probe property curve consists of three segments in the order of increasing beam current: (i) the constant probe size region, (ii) the brightness limited region where the probe size increases as d approximately I(b)(3/8), and (iii) the angular current intensity limited region in which the beam size increases rapidly as d approximately I(b)(3/2). Some strategies are suggested to increase the threshold beam current and to extend the effective beam current range of the point cathode gun into micro ampere regime.

  4. NASA GRC and MSFC Space-Plasma Arc Testing Procedures

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.; Vayner, Boris V.; Galofaro, Joel T,; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd

    2005-01-01

    Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. To be discussed are: 1.Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debuy lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. 5. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Prevention sustained discharges during testing. 6. Real array or structure samples versus idealized samples. 7. Validity of LEO tests for GEO samples. 8. Extracting arc threshold information from arc rate versus voltage tests. 9. Snapover and current collection at positive sample bias. Glows at positive bias. Kapon (R) pyrolisis. 10. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 11. Testing for Paschen discharge threshold. Testing for dielectric breakdown thresholds. Testing for tether arcing. 12. Testing in very dense plasmas (ie thruster plumes). 13. Arc mitigation strategies. Charging mitigation strategies. Models. 14. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

  5. NASA GRC and MSFC Space-Plasma Arc Testing Procedures

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.a; Vayner, Boris V.; Galofaro, Joel T.; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd

    2005-01-01

    Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space flight Center (MSFC) for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing testing standardization. To be discussed are: 1. Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debye lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Preventing sustained discharges during testing. 5. Real array or structure samples versus idealized samples. 6. Validity of LEO tests for GEO samples. 7. Extracting arc threshold information from arc rate versus voltage tests. 8 . Snapover and current collection at positive sample bias. Glows at positive bias. Kapton pyrolization. 9. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 10. Testing for Paschen discharge thresholds. Testing for dielectric breakdown thresholds. Testing for tether arcing. 11. Testing in very dense plasmas (ie thruster plumes). 12. Arc mitigation strategies. Charging mitigation strategies. Models. 13. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

  6. Optimal Dynamic Sub-Threshold Technique for Extreme Low Power Consumption for VLSI

    NASA Technical Reports Server (NTRS)

    Duong, Tuan A.

    2012-01-01

    For miniaturization of electronics systems, power consumption plays a key role in the realm of constraints. Considering the very large scale integration (VLSI) design aspect, as transistor feature size is decreased to 50 nm and below, there is sizable increase in the number of transistors as more functional building blocks are embedded in the same chip. However, the consequent increase in power consumption (dynamic and leakage) will serve as a key constraint to inhibit the advantages of transistor feature size reduction. Power consumption can be reduced by minimizing the voltage supply (for dynamic power consumption) and/or increasing threshold voltage (V(sub th), for reducing leakage power). When the feature size of the transistor is reduced, supply voltage (V(sub dd)) and threshold voltage (V(sub th)) are also reduced accordingly; then, the leakage current becomes a bigger factor of the total power consumption. To maintain low power consumption, operation of electronics at sub-threshold levels can be a potentially strong contender; however, there are two obstacles to be faced: more leakage current per transistor will cause more leakage power consumption, and slow response time when the transistor is operated in weak inversion region. To enable low power consumption and yet obtain high performance, the CMOS (complementary metal oxide semiconductor) transistor as a basic element is viewed and controlled as a four-terminal device: source, drain, gate, and body, as differentiated from the traditional approach with three terminals: i.e., source and body, drain, and gate. This technique features multiple voltage sources to supply the dynamic control, and uses dynamic control to enable low-threshold voltage when the channel (N or P) is active, for speed response enhancement and high threshold voltage, and when the transistor channel (N or P) is inactive, to reduce the leakage current for low-leakage power consumption.

  7. Domain wall dynamics driven by spin transfer torque and the spin-orbit field.

    PubMed

    Hayashi, Masamitsu; Nakatani, Yoshinobu; Fukami, Shunsuke; Yamanouchi, Michihiko; Mitani, Seiji; Ohno, Hideo

    2012-01-18

    We have studied current-driven dynamics of domain walls when an in-plane magnetic field is present in perpendicularly magnetized nanowires using an analytical model and micromagnetic simulations. We model an experimentally studied system, ultrathin magnetic nanowires with perpendicular anisotropy, where an effective in-plane magnetic field is developed when current is passed along the nanowire due to the Rashba-like spin-orbit coupling. Using a one-dimensional model of a domain wall together with micromagnetic simulations, we show that the existence of such in-plane magnetic fields can either lower or raise the threshold current needed to cause domain wall motion. In the presence of the in-plane field, the threshold current differs for positive and negative currents for a given wall chirality, and the wall motion becomes sensitive to out-of-plane magnetic fields. We show that large non-adiabatic spin torque can counteract the effect of the in-plane field.

  8. Sensitivity of frozen section histology for identifying Propionibacterium acnes infections in revision shoulder arthroplasty.

    PubMed

    Grosso, Matthew J; Frangiamore, Salvatore J; Ricchetti, Eric T; Bauer, Thomas W; Iannotti, Joseph P

    2014-03-19

    Propionibacterium acnes is a clinically relevant pathogen with total shoulder arthroplasty. The purpose of this study was to determine the sensitivity of frozen section histology in identifying patients with Propionibacterium acnes infection during revision total shoulder arthroplasty and investigate various diagnostic thresholds of acute inflammation that may improve frozen section performance. We reviewed the results of forty-five patients who underwent revision total shoulder arthroplasty. Patients were divided into the non-infection group (n = 15), the Propionibacterium acnes infection group (n = 18), and the other infection group (n = 12). Routine preoperative testing was performed and intraoperative tissue culture and frozen section histology were collected for each patient. The histologic diagnosis was determined by one pathologist for each of the four different thresholds. The absolute maximum polymorphonuclear leukocyte concentration was used to construct a receiver operating characteristics curve to determine a new potential optimal threshold. Using the current thresholds for grading frozen section histology, the sensitivity was lower for the Propionibacterium acnes infection group (50%) compared with the other infection group (67%). The specificity of frozen section was 100%. Using a receiver operating characteristics curve, an optimized threshold was found at a total of ten polymorphonuclear leukocytes in five high-power fields (400×). Using this threshold, the sensitivity of frozen section for Propionibacterium acnes was increased to 72%, and the specificity remained at 100%. Using current histopathology grading systems, frozen sections were specific but showed low sensitivity with respect to the Propionibacterium acnes infection. A new threshold value of a total of ten or more polymorphonuclear leukocytes in five high-power fields may increase the sensitivity of frozen section, with minimal impact on specificity.

  9. Energy Switching Threshold for Climatic Benefits

    NASA Astrophysics Data System (ADS)

    Zhang, X.; Cao, L.; Caldeira, K.

    2013-12-01

    Climate change is one of the great challenges facing humanity currently and in the future. Its most severe impacts may still be avoided if efforts are made to transform current energy systems (1). A transition from the global system of high Greenhouse Gas (GHG) emission electricity generation to low GHG emission energy technologies is required to mitigate climate change (2). Natural gas is increasingly seen as a choice for transitions to renewable sources. However, recent researches in energy and climate puzzled about the climate implications of relying more energy on natural gas. On one hand, a shift to natural gas is promoted as climate mitigation because it has lower carbon per unit energy than coal (3). On the other hand, the effect of switching to natural gas on nuclear-power and other renewable energies development may offset benefits from fuel-switching (4). Cheap natural gas is causing both coal plants and nuclear plants to close in the US. The objective of this study is to measure and evaluate the threshold of energy switching for climatic benefits. We hypothesized that the threshold ratio of energy switching for climatic benefits is related to GHGs emission factors of energy technologies, but the relation is not linear. A model was developed to study the fuel switching threshold for greenhouse gas emission reduction, and transition from coal and nuclear electricity generation to natural gas electricity generation was analyzed as a case study. The results showed that: (i) the threshold ratio of multi-energy switching for climatic benefits changes with GHGs emission factors of energy technologies. (ii)The mathematical relation between the threshold ratio of energy switching and GHGs emission factors of energies is a curved surface function. (iii) The analysis of energy switching threshold for climatic benefits can be used for energy and climate policy decision support.

  10. Assessment of the current D-dimer cutoff point in pulmonary embolism workup at a single institution: Retrospective study.

    PubMed

    Alhassan, S; Bihler, E; Patel, K; Lavudi, S; Young, M; Balaan, M

    2018-06-06

    The currently used D-dimer (DD) cutoff point is associated with a large number of negative CT-pulmonary angiographies (CTPA). We hypothesized presence of deficiency in the current cutoff and a need to look for a better DD threshold. We conducted a retrospective medical records analysis of all patients who had a CTPA as part of pulmonary embolism (PE) workup over a 1-year period. All emergency room (ER) patients who had DD assay checked prior to CTPA were included in the analysis. We assessed our institutional cutoff point and tried to test other presumptive DD thresholds retrospectively. At our institution 1591 CTPA were performed in 2014, with 1220 scans (77%) performed in the ER. DD test was ordered prior to CTPA imaging in 238 ER patients (19.5%) as part of the PE workup. PE was diagnosed in 14 cases (6%). The sensitivity and specificity of the currently used DD cutoff (0.5 mcg/mL) were found to be 100% and 13%, respectively. Shifting the cutoff value from 0.5 to 0.85 mcg/mL would result in a significant increase in the specificity from 13% to 51% while maintaining the same sensitivity of 100%. This would make theoretically 84 CTPA scans, corresponding to 35% of CTPA imaging, unnecessary because DD would be considered negative based on this presumptive threshold. Our results suggest a significant deficiency in the institutional DD cutoff point with the need to find a better threshold through a large multicenter prospective trial to minimize unnecessary CTPA scans and to improve patient safety.

  11. Reciprocal Modulation of IK1–INa Extends Excitability in Cardiac Ventricular Cells

    PubMed Central

    Varghese, Anthony

    2016-01-01

    The inwardly rectifying potassium current (IK1) and the fast inward sodium current (INa) are reciprocally modulated in mammalian ventricular myocytes. An increase in the expression of channels responsible for one of these two currents results in a corresponding increase in expression of the other. These currents are critical in the propagation of action potentials (AP) during the normal functioning of the heart. This study identifies a physiological role for IK1–INa reciprocal modulation in ventricular fiber activation thresholds and conduction. Simulations of action potentials in single cells and propagating APs in cardiac fibers were carried out using an existing model of electrical activity in cardiac ventricular myocytes. The conductances, GK1, of the inwardly rectifying potassium current, and GNa, of the fast inward sodium current were modified independently and in tandem to simulate reciprocal modulation. In single cells, independent modulation of GK1 alone resulted in changes in activation thresholds that were qualitatively similar to those for reciprocal GK1–GNa modulation and unlike those due to independent modulation of GNa alone, indicating that GK1 determines the cellular activation threshold. On the other hand, the variations in conduction velocity in cardiac cell fibers were similar for independent GNa modulation and for tandem changes in GK1–GNa, suggesting that GNa is primarily responsible for setting tissue AP conduction velocity. Conduction velocity dependence on GK1–GNa is significantly affected by the intercellular gap junction conductance. While the effects on the passive fiber space constant due to changes in both GK1 and the intercellular gap junction conductance, Ggj, were in line with linear cable theory predictions, both conductances had surprisingly large effects on fiber activation thresholds. Independent modulation of GK1 rendered cardiac fibers inexcitable at higher levels of GK1 whereas tandem GK1–GNa changes allowed fibers to remain excitable at high GK1 values. Reciprocal modulation of the inwardly rectifying potassium current and the fast inward sodium current may have a functional role in allowing cardiac tissue to remain excitable when IK1 is upregulated. PMID:27895596

  12. Center conductor diagnostic for multipactor detection in inaccessible geometries

    NASA Astrophysics Data System (ADS)

    Chaplin, Vernon H.; Hubble, Aimee A.; Clements, Kathryn A.; Graves, Timothy P.

    2017-01-01

    Electron collecting current probes are the most reliable diagnostic of multipactor and radiofrequency (RF) ionization breakdown; however, stand-alone probes can only be used in test setups where the breakdown region is physically accessible. This paper describes techniques for measuring multipactor current directly on the center conductor of a coaxial RF device (or more generally, on the signal line in any two-conductor RF system) enabling global multipactor detection with improved sensitivity compared to other common diagnostics such as phase null, third harmonic, and reflected power. The center conductor diagnostic may be AC coupled for use in systems with a low DC impedance between the center conductor and ground. The effect of DC bias on the breakdown threshold was studied: in coaxial geometry, the change in threshold was <1 dB for positive biases satisfying VD C/VR F 0 <0.8 , where VRF0 is the RF voltage amplitude at the unperturbed breakdown threshold. In parallel plate geometry, setting VD C/VR F 0 <0.2 was necessary to avoid altering the threshold by more than 1 dB. In most cases, the center conductor diagnostic functions effectively with no bias at all—this is the preferred implementation, but biases in the range VD C=0 -10 V may be applied if necessary. The polarity of the detected current signal may be positive or negative depending on whether there is net electron collection or emission globally.

  13. Center conductor diagnostic for multipactor detection in inaccessible geometries.

    PubMed

    Chaplin, Vernon H; Hubble, Aimee A; Clements, Kathryn A; Graves, Timothy P

    2017-01-01

    Electron collecting current probes are the most reliable diagnostic of multipactor and radiofrequency (RF) ionization breakdown; however, stand-alone probes can only be used in test setups where the breakdown region is physically accessible. This paper describes techniques for measuring multipactor current directly on the center conductor of a coaxial RF device (or more generally, on the signal line in any two-conductor RF system) enabling global multipactor detection with improved sensitivity compared to other common diagnostics such as phase null, third harmonic, and reflected power. The center conductor diagnostic may be AC coupled for use in systems with a low DC impedance between the center conductor and ground. The effect of DC bias on the breakdown threshold was studied: in coaxial geometry, the change in threshold was <1 dB for positive biases satisfying V DC /V RF0 <0.8, where V RF0 is the RF voltage amplitude at the unperturbed breakdown threshold. In parallel plate geometry, setting V DC /V RF0 <0.2 was necessary to avoid altering the threshold by more than 1 dB. In most cases, the center conductor diagnostic functions effectively with no bias at all-this is the preferred implementation, but biases in the range V DC =0-10V may be applied if necessary. The polarity of the detected current signal may be positive or negative depending on whether there is net electron collection or emission globally.

  14. Development of a wave-induced forcing threshold for nearshore impact of Wave Energy Converter arrays

    NASA Astrophysics Data System (ADS)

    O'Dea, A.; Haller, M. C.; Ozkan-Haller, H. T.

    2016-02-01

    Wave-induced forcing is a function of spatial gradients in the wave radiation stresses and is the main driver of alongshore currents, rip currents, and nearshore sediment transport. The installation of nearshore Wave Energy Converter (WEC) arrays may cause significant changes in the surf zone radiation stresses and could therefore impact nearshore littoral processes. In the first part of this study, a new threshold for nearshore hydrodynamic impact due to the presence of WEC devices is established based on changes in the alongshore radiation stress gradients shoreward of WEC arrays. The threshold is defined based on the relationship between nearshore radiation stresses and alongshore currents as observed in field data. Next, we perform a parametric study of the nearshore impact of WEC arrays using the SWAN wave model. Trials are conducted on an idealized, alongshore-uniform beach with a range of WEC array configurations, locations, and incident wave conditions, and conditions that generate radiation stress gradients above the impact threshold are identified. Finally, the same methodology is applied to two wave energy test sites off the coast of Newport, OR with more complicated bathymetries. Although the trends at the field sites are similar to those seen in the parametric study, the location and extent of the changes in the alongshore radiation stress gradients appear to be heavily influenced by the local bathymetry.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anastasiou, Charalampos; Duhr, Claude; Dulat, Falko

    In this study, we compute the gluon fusion Higgs boson cross-section at N 3LO through the second term in the threshold expansion. This calculation constitutes a major milestone towards the full N 3LO cross section. Our result has the best formal accuracy in the threshold expansion currently available, and includes contributions from collinear regions besides subleading corrections from soft and hard regions, as well as certain logarithmically enhanced contributions for general kinematics. We use our results to perform a critical appraisal of the validity of the threshold approximation at N 3LO in perturbative QCD.

  16. Oscillatory dependence of current driven domain wall motion on current pulse length

    NASA Astrophysics Data System (ADS)

    Thomas, Luc

    2007-03-01

    The motion of domain walls (DW) in magnetic nanowires driven by spin torque from spin-polarized current is of considerable interest. Most previous work has considered the effect of dc or ˜microsecond long current pulses. Here, we show that the dynamics of DWs driven by nanosecond-long current pulses is unexpectedly complex. In particular, we show that the current driven motion of a DW, confined to a pinning site in a permalloy nanowire, exhibits an oscillatory dependence on the current pulse length with a period of just a few nanoseconds [1]. This behavior can be understood within a surprisingly straightforward one dimensional analytical model of the DW's motion. When a current pulse is applied, the DW's position oscillates within the pinning potential out of phase with the DW's out-of-plane magnetization, where the latter acts like the DW's momentum. Thus, the current driven motion of the DW is akin to a harmonic oscillator, whose frequency is determined by the ``mass'' of the DW and where the restoring force is related to the slope of the pinning potential. Remarkably, when the current pulse is turned off during phases of the DW motion when it has enough momentum, the amplitude of the oscillations can be amplified such that the DW exits the pinning potential well after the pulse is turned off. This oscillatory depinning occurs for currents smaller than the dc threshold current, and, moreover, the DW moves against the electron flow, opposite to the propagation direction above the dc threshold. These effects can be further amplified by using trains of current pulses whose lengths and separations are matched to the DW's oscillation period. In this way, we have demonstrated a five fold reduction in the threshold current required to move a DW out of a pinning site, making this effect potentially important for technological applications. [1] L. Thomas, M. Hayashi, X. Jiang, R. Moriya, C. Rettner and S.S.P. Parkin, Nature 443, 197 (2006).

  17. Kv1 channels control spike threshold dynamics and spike timing in cortical pyramidal neurones

    PubMed Central

    Higgs, Matthew H; Spain, William J

    2011-01-01

    Abstract Previous studies showed that cortical pyramidal neurones (PNs) have a dynamic spike threshold that functions as a high-pass filter, enhancing spike timing in response to high-frequency input. While it is commonly assumed that Na+ channel inactivation is the primary mechanism of threshold accommodation, the possible role of K+ channel activation in fast threshold changes has not been well characterized. The present study tested the hypothesis that low-voltage activated Kv1 channels affect threshold dynamics in layer 2–3 PNs, using α-dendrotoxin (DTX) or 4-aminopyridine (4-AP) to block these conductances. We found that Kv1 blockade reduced the dynamic changes of spike threshold in response to a variety of stimuli, including stimulus-evoked synaptic input, current steps and ramps of varied duration, and noise. Analysis of the responses to noise showed that Kv1 channels increased the coherence of spike output with high-frequency components of the stimulus. A simple model demonstrates that a dynamic spike threshold can account for this effect. Our results show that the Kv1 conductance is a major mechanism that contributes to the dynamic spike threshold and precise spike timing of cortical PNs. PMID:21911608

  18. New developments in supra-threshold perimetry.

    PubMed

    Henson, David B; Artes, Paul H

    2002-09-01

    To describe a series of recent enhancements to supra-threshold perimetry. Computer simulations were used to develop an improved algorithm (HEART) for the setting of the supra-threshold test intensity at the beginning of a field test, and to evaluate the relationship between various pass/fail criteria and the test's performance (sensitivity and specificity) and how they compare with modern threshold perimetry. Data were collected in optometric practices to evaluate HEART and to assess how the patient's response times can be analysed to detect false positive response errors in visual field test results. The HEART algorithm shows improved performance (reduced between-eye differences) over current algorithms. A pass/fail criterion of '3 stimuli seen of 3-5 presentations' at each test location reduces test/retest variability and combines high sensitivity and specificity. A large percentage of false positive responses can be detected by comparing their latencies to the average response time of a patient. Optimised supra-threshold visual field tests can perform as well as modern threshold techniques. Such tests may be easier to perform for novice patients, compared with the more demanding threshold tests.

  19. Stability of plasma cylinder with current in a helical plasma flow

    NASA Astrophysics Data System (ADS)

    Leonovich, Anatoly S.; Kozlov, Daniil A.; Zong, Qiugang

    2018-04-01

    Stability of a plasma cylinder with a current wrapped by a helical plasma flow is studied. Unstable surface modes of magnetohydrodynamic (MHD) oscillations develop at the boundary of the cylinder enwrapped by the plasma flow. Unstable eigenmodes can also develop for which the plasma cylinder is a waveguide. The growth rate of the surface modes is much higher than that for the eigenmodes. It is shown that the asymmetric MHD modes in the plasma cylinder are stable if the velocity of the plasma flow is below a certain threshold. Such a plasma flow velocity threshold is absent for the symmetric modes. They are unstable in any arbitrarily slow plasma flows. For all surface modes there is an upper threshold for the flow velocity above which they are stable. The helicity index of the flow around the plasma cylinder significantly affects both the Mach number dependence of the surface wave growth rate and the velocity threshold values. The higher the index, the lower the upper threshold of the velocity jump above which the surface waves become stable. Calculations have been carried out for the growth rates of unstable oscillations in an equilibrium plasma cylinder with current serving as a model of the low-latitude boundary layer (LLBL) of the Earth's magnetic tail. A tangential discontinuity model is used to simulate the geomagnetic tail boundary. It is shown that the magnetopause in the geotail LLBL is unstable to a surface wave (having the highest growth rate) in low- and medium-speed solar wind flows, but becomes stable to this wave in high-speed flows. However, it can remain weakly unstable to the radiative modes of MHD oscillations.

  20. Detecting fatigue thresholds from electromyographic signals: A systematic review on approaches and methodologies.

    PubMed

    Ertl, Peter; Kruse, Annika; Tilp, Markus

    2016-10-01

    The aim of the current paper was to systematically review the relevant existing electromyographic threshold concepts within the literature. The electronic databases MEDLINE and SCOPUS were screened for papers published between January 1980 and April 2015 including the keywords: neuromuscular fatigue threshold, anaerobic threshold, electromyographic threshold, muscular fatigue, aerobic-anaerobictransition, ventilatory threshold, exercise testing, and cycle-ergometer. 32 articles were assessed with regard to their electromyographic methodologies, description of results, statistical analysis and test protocols. Only one article was of very good quality. 21 were of good quality and two articles were of very low quality. The review process revealed that: (i) there is consistent evidence of one or two non-linear increases of EMG that might reflect the additional recruitment of motor units (MU) or different fiber types during fatiguing cycle ergometer exercise, (ii) most studies reported no statistically significant difference between electromyographic and metabolic thresholds, (iii) one minute protocols with increments between 10 and 25W appear most appropriate to detect muscular threshold, (iv) threshold detection from the vastus medialis, vastus lateralis, and rectus femoris is recommended, and (v) there is a great variety in study protocols, measurement techniques, and data processing. Therefore, we recommend further research and standardization in the detection of EMGTs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Identifying and Overcoming Threshold Concepts and Conceptions: Introducing a Conception-Focused Curriculum to Course Design

    ERIC Educational Resources Information Center

    Burch, Gerald F.; Burch, Jana J.; Bradley, Thomas P.; Heller, Nathan A.

    2015-01-01

    Educators have been challenged to identify threshold concepts and develop transformed students. This stands in stark contrast to many curriculum design and delivery models that currently view students as repositories of knowledge. In this article, we argue that educators can reach both goals, identify stumbling blocks and transforming students,…

  2. 76 FR 64983 - Self-Regulatory Organizations; NYSE Amex LLC; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-19

    ...-Regulatory Organizations; NYSE Amex LLC; Notice of Filing and Immediate Effectiveness of Proposed Rule Change... currently count toward both the $350,000 cap and the 3,500,000 thresholds, but are not themselves capped... standard fee schedule, with the exception of transactions that exceed the fee cap threshold for Specialists...

  3. Olfactory Detection Thresholds and Adaptation in Adults with Autism Spectrum Condition

    ERIC Educational Resources Information Center

    Tavassoli, T.; Baron-Cohen, S.

    2012-01-01

    Sensory issues have been widely reported in Autism Spectrum Conditions (ASC). Since olfaction is one of the least investigated senses in ASC, the current studies explore olfactory detection thresholds and adaptation to olfactory stimuli in adults with ASC. 80 participants took part, 38 (18 females, 20 males) with ASC and 42 control participants…

  4. Sex-Specific Differences in Agonistic Behaviour, Sound Production and Auditory Sensitivity in the Callichthyid Armoured Catfish Megalechis thoracata

    PubMed Central

    Hadjiaghai, Oliwia; Ladich, Friedrich

    2015-01-01

    Background Data on sex-specific differences in sound production, acoustic behaviour and hearing abilities in fishes are rare. Representatives of numerous catfish families are known to produce sounds in agonistic contexts (intraspecific aggression and interspecific disturbance situations) using their pectoral fins. The present study investigates differences in agonistic behaviour, sound production and hearing abilities in males and females of a callichthyid catfish. Methodology/Principal Findings Eight males and nine females of the armoured catfish Megalechis thoracata were investigated. Agonistic behaviour displayed during male-male and female-female dyadic contests and sounds emitted were recorded, sound characteristics analysed and hearing thresholds measured using the auditory evoked potential (AEP) recording technique. Male pectoral spines were on average 1.7-fold longer than those of same-sized females. Visual and acoustic threat displays differed between sexes. Males produced low-frequency harmonic barks at longer distances and thumps at close distances, whereas females emitted broad-band pulsed crackles when close to each other. Female aggressive sounds were significantly shorter than those of males (167 ms versus 219 to 240 ms) and of higher dominant frequency (562 Hz versus 132 to 403 Hz). Sound duration and sound level were positively correlated with body and pectoral spine length, but dominant frequency was inversely correlated only to spine length. Both sexes showed a similar U-shaped hearing curve with lowest thresholds between 0.2 and 1 kHz and a drop in sensitivity above 1 kHz. The main energies of sounds were located at the most sensitive frequencies. Conclusions/Significance Current data demonstrate that both male and female M. thoracata produce aggressive sounds, but the behavioural contexts and sound characteristics differ between sexes. Sexes do not differ in hearing, but it remains to be clarified if this is a general pattern among fish. This is the first study to describe sex-specific differences in agonistic behaviour in fishes. PMID:25775458

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael, Stephan; Chow, Weng; Schneider, Hans

    In the framework of a microscopic model for intersubband gain from electrically pumped quantum-dot structures we investigate electrically pumped quantum-dots as active material for a mid-infrared quantum cascade laser. Our previous calculations have indicated that these structures could operate with reduced threshold current densities while also achieving a modal gain comparable to that of quantum well active materials. We study the influence of two important quantum-dot material parameters, here, namely inhomogeneous broadening and quantum-dot sheet density, on the performance of a proposed quantum cascade laser design. In terms of achieving a positive modal net gain, a high quantum-dot density canmore » compensate for moderately high inhomogeneous broadening, but at a cost of increased threshold current density. By minimizing quantum-dot density with presently achievable inhomogeneous broadening and total losses, significantly lower threshold densities than those reported in quantum-well quantum-cascade lasers are predicted by our theory.« less

  6. Improvement in Brightness Uniformity by Compensating for the Threshold Voltages of Both the Driving Thin-Film Transistor and the Organic Light-Emitting Diode for Active-Matrix Organic Light-Emitting Diode Displays

    NASA Astrophysics Data System (ADS)

    Ching-Lin Fan,; Hui-Lung Lai,; Jyu-Yu Chang,

    2010-05-01

    In this paper, we propose a novel pixel design and driving method for active-matrix organic light-emitting diode (AM-OLED) displays using low-temperature polycrystalline silicon thin-film transistors (LTPS-TFTs). The proposed threshold voltage compensation circuit, which comprised five transistors and two capacitors, has been verified to supply uniform output current by simulation work using the automatic integrated circuit modeling simulation program with integrated circuit emphasis (AIM-SPICE) simulator. The driving scheme of this voltage programming method includes four periods: precharging, compensation, data input, and emission. The simulated results demonstrate excellent properties such as low error rate of OLED anode voltage variation (<1%) and high output current. The proposed pixel circuit shows high immunity to the threshold voltage deviation characteristics of both the driving poly-Si TFT and the OLED.

  7. Stable Extraction of Threshold Voltage Using Transconductance Change Method for CMOS Modeling, Simulation and Characterization

    NASA Astrophysics Data System (ADS)

    Choi, Woo Young; Woo, Dong-Soo; Choi, Byung Yong; Lee, Jong Duk; Park, Byung-Gook

    2004-04-01

    We proposed a stable extraction algorithm for threshold voltage using transconductance change method by optimizing node interval. With the algorithm, noise-free gm2 (=dgm/dVGS) profiles can be extracted within one-percent error, which leads to more physically-meaningful threshold voltage calculation by the transconductance change method. The extracted threshold voltage predicts the gate-to-source voltage at which the surface potential is within kT/q of φs=2φf+VSB. Our algorithm makes the transconductance change method more practical by overcoming noise problem. This threshold voltage extraction algorithm yields the threshold roll-off behavior of nanoscale metal oxide semiconductor field effect transistor (MOSFETs) accurately and makes it possible to calculate the surface potential φs at any other point on the drain-to-source current (IDS) versus gate-to-source voltage (VGS) curve. It will provide us with a useful analysis tool in the field of device modeling, simulation and characterization.

  8. Comparison of alternatives to amplitude thresholding for onset detection of acoustic emission signals

    NASA Astrophysics Data System (ADS)

    Bai, F.; Gagar, D.; Foote, P.; Zhao, Y.

    2017-02-01

    Acoustic Emission (AE) monitoring can be used to detect the presence of damage as well as determine its location in Structural Health Monitoring (SHM) applications. Information on the time difference of the signal generated by the damage event arriving at different sensors in an array is essential in performing localisation. Currently, this is determined using a fixed threshold which is particularly prone to errors when not set to optimal values. This paper presents three new methods for determining the onset of AE signals without the need for a predetermined threshold. The performance of the techniques is evaluated using AE signals generated during fatigue crack growth and compared to the established Akaike Information Criterion (AIC) and fixed threshold methods. It was found that the 1D location accuracy of the new methods was within the range of < 1 - 7.1 % of the monitored region compared to 2.7% for the AIC method and a range of 1.8-9.4% for the conventional Fixed Threshold method at different threshold levels.

  9. Modeling and analysis of sub-surface leakage current in nano-MOSFET under cutoff regime

    NASA Astrophysics Data System (ADS)

    Swami, Yashu; Rai, Sanjeev

    2017-02-01

    The high leakage current in nano-meter regimes is becoming a significant portion of power dissipation in nano-MOSFET circuits as threshold voltage, channel length, and gate oxide thickness are scaled down to nano-meter range. Precise leakage current valuation and meticulous modeling of the same at nano-meter technology scale is an increasingly a critical work in designing the low power nano-MOSFET circuits. We present a specific compact model for sub-threshold regime leakage current in bulk driven nano-MOSFETs. The proposed logical model is instigated and executed into the latest updated PTM bulk nano-MOSFET model and is found to be in decent accord with technology-CAD simulation data. This paper also reviews various transistor intrinsic leakage mechanisms for nano-MOSFET exclusively in weak inversion, like drain-induced barricade lowering (DIBL), gate-induced drain leakage (GIDL), gate oxide tunneling (GOT) leakage etc. The root cause of the sub-surface leakage current is mainly due to the nano-scale short channel length causing source-drain coupling even in sub-threshold domain. Consequences leading to carriers triumphing the barricade between the source and drain. The enhanced model effectively considers the following parameter dependence in the account for better-quality value-added results like drain-to-source bias (VDS), gate-to-source bias (VGS), channel length (LG), source/drain junction depth (Xj), bulk doping concentration (NBULK), and operating temperature (Top).

  10. Comparative investigation of novel hetero gate dielectric and drain engineered charge plasma TFET for improved DC and RF performance

    NASA Astrophysics Data System (ADS)

    Yadav, Dharmendra Singh; Verma, Abhishek; Sharma, Dheeraj; Tirkey, Sukeshni; Raad, Bhagwan Ram

    2017-11-01

    Tunnel-field-effect-transistor (TFET) has emerged as one of the most prominent devices to replace conventional MOSFET due to its ability to provide sub-threshold slope below 60 mV/decade (SS ≤ 60 mV/decade) and low leakage current. Despite this, TFETs suffer from ambipolar behavior, lower ON-state current, and poor RF performance. To address these issues, we have introduced drain and gate work function engineering with hetero gate dielectric for the first time in charge plasma based doping-less TFET (DL TFET). In this, the usage of dual work functionality over the drain region significantly reduces the ambipolar behavior of the device by varying the energy barrier at drain/channel interface. Whereas, the presence of dual work function at the gate terminal increases the ON-state current (ION). The combined effect of dual work function at the gate and drain electrode results in the increment of ON-state current (ION) and decrement of ambipolar conduction (Iambi) respectively. Furthermore, the incorporation of hetero gate dielectric along with dual work functionality at the drain and gate electrode provides an overall improvement in the performance of the device in terms of reduction in ambipolarity, threshold voltage and sub-threshold slope along with improved ON-state current and high frequency figures of merit.

  11. Threshold fluctuations in a superconducting current-carrying bridge

    NASA Astrophysics Data System (ADS)

    Marychev, P. M.; Vodolazov, D. Yu

    2017-07-01

    We calculate the energy of threshold fluctuation δ {F}{{thr}} which triggers the transition of a superconducting current-carrying bridge to the resistive state. We show that the dependence δ {F}{{thr}}{(I)\\propto {I}{{dep}}{\\hslash }(1-I/{I}{{dep}})}5/4/e, found by Langer and Ambegaokar for a long bridge with length L\\gg ξ , holds far below the critical temperature in both dirty and clean limits (here I dep is the depairing current of the bridge and ξ is a coherence length). We also find that even a ‘weak’ local defect (leading to a small suppression of the critical current of the bridge {I}{{c}}≲ {I}{{dep}}) provides δ {F}{{thr}}\\propto {I}{{c}}{\\hslash }{(1-I/{I}{{c}})}3/2/e, typical for a short bridge with L\\ll ξ or a Josephson junction.

  12. Independent associations of childhood and current socioeconomic status with risk of self-reported doctor-diagnosed arthritis in a family-medicine cohort of North-Carolinians.

    PubMed

    Baldassari, Antoine R; Cleveland, Rebecca J; Callahan, Leigh F

    2013-11-20

    Associations of socioeconomic status (SES) with the prevalence of various forms of arthritis are well documented. Increasing evidence suggests that SES during childhood is a lasting determinant of health, but its association with the onset of arthritis remains unclear. Cross-sectional data on 1276 participants originated from 22 family practices in North-Carolina, USA. We created 4-level (high, medium, low, lowest) current SES and childhood SES summary scores based on parental and participant education, occupation and homeownership. We investigated associations of individual SES characteristics, summary scores and SES trajectories (e.g. high/low) with self-reported arthritis in logistic regression models progressively adjusted for race and gender, age, then BMI, and clustered by family practice. We found evidence for independent associations of both childhood and current SES with the reporting of arthritis across our models. In covariate-adjusted models simultaneously including current and childhood SES, compared with high SES participants in the lowest childhood SES category (OR = 1.39 [95% CI = 1.04, 1.85]) and those in the low (OR = 1.66 [95% CI = 1.14, 2.42]) and lowest (OR = 2.08 [95% CI = 1.16, 3.74]) categories of current SES had significantly greater odds of having self-reported arthritis. Current SES and childhood SES are both associated with the odds of reporting arthritis within this primary-care population, although the possibly superseding influence of existing circumstances must be noted. BMI was a likely mechanism in the association of childhood SES with arthritis onset, and research is needed to elucidate further pathways linking the socioeconomic environment across life-stages and the development of rheumatic diseases.

  13. Two-Color Coherent Control of Femtosecond Above-Threshold Photoemission from a Tungsten Nanotip.

    PubMed

    Förster, Michael; Paschen, Timo; Krüger, Michael; Lemell, Christoph; Wachter, Georg; Libisch, Florian; Madlener, Thomas; Burgdörfer, Joachim; Hommelhoff, Peter

    2016-11-18

    We demonstrate coherent control of multiphoton and above-threshold photoemission from a single solid-state nanoemitter driven by a fundamental and a weak second harmonic laser pulse. Depending on the relative phase of the two pulses, electron emission is modulated with a contrast of the oscillating current signal of up to 94%. Electron spectra reveal that all observed photon orders are affected simultaneously and similarly. We confirm that photoemission takes place within 10 fs. Accompanying simulations indicate that the current modulation with its large contrast results from two interfering quantum pathways leading to electron emission.

  14. INTERNATIONAL CONFERENCE ON SEMICONDUCTOR INJECTION LASERS SELCO-87: Low-threshold ridge-waveguide 1.3-μm laser

    NASA Astrophysics Data System (ADS)

    Kortàn, J.; Nohavica, D.; Sarma, J.

    1988-11-01

    A description is given of the fabrication and of the main properties of 1.3-μm GaInAsP lasers with a ridge (rib) waveguide structure used for lateral confinement of transverse modes and of the current. Such lasers were made by the method of ion-beam etching and self-alignment photolithography. Narrow ridges (3-5 μm) formed in this way carried Ti-Au Schottky contacts. These lasers were simple to fabricate and their threshold currents were comparable with those in much more complex lasers with buried waveguide structures.

  15. Experimental and theoretical investigations concerning a frequency filter behavior of the human retina regarding electric pulse currents. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Meier-Koll, A.

    1979-01-01

    Investigation involving patients with injuries in the visual nervous system are discussed. This led to the identification of the epithelial ganglion of the retina as a frequency filter. Threshold curves of the injured visual organs were compared with threshold curves obtained with a control group as a basis for identification. A model which considers the epithelial ganglion as a homogeneous cell layer in which adjacent neurons interact is discussed. It is shown the behavior of the cells against alternating exciting currents can be explained.

  16. Algorithm for measuring the internal quantum efficiency of individual injection lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sommers, H.S. Jr.

    1978-05-01

    A new algorithm permits determination of the internal quantum efficiency eta/sub i/ of individual lasers. Above threshold, the current is partitioned into a ''coherent'' component driving the lasing modes and the ''noncoherent'' remainder. Below threshold the current is known to grow as exp(qV/n/sub 0/KT); the algorithm proposes that extrapolation of this equation into the lasing region measures the noncoherent remainder, enabling deduction of the coherent component and of its current derivative eta/sub i/. Measurements on five (AlGa)As double-heterojunction lasers cut from one wafer demonstrate the power of the new method. Comparison with band calculations of Stern shows that n/sub 0/more » originates in carrier degeneracy.« less

  17. Lifecourse educational status in relation to weight gain in African American women.

    PubMed

    Coogan, Patricia E; Wise, Lauren A; Cozier, Yvette C; Palmer, Julie R; Rosenberg, Lynn

    2012-01-01

    Childhood disadvantage has been associated with increased risk of obesity from childhood through adulthood and those who are disadvantaged across the lifecourse are at highest risk. The effect of lifecourse socioeconomic status (SES) is particularly important for Black women due to the higher prevalence of low SES and obesity in Black compared to White women. We assessed associations of lifecourse SES, as indicated by educational status, with adult weight in African American women. We assessed the associations of parental education, current education (education of participant or her spouse), and a combination of parental and current education (lifecourse education) with weight gain among 21,457 women aged < 55 years in the longitudinal Black Women's Health Study, which began in 1995. We estimated the mean difference in weight gain between age 18 and age in 2009, and risk ratios for obesity in 2009, in each level of education compared to the highest level (college graduate). The age- and height-adjusted differences in mean weight gain for the lowest levels of parental and current education compared to the highest levels were 3.29 and 4.49 kg, respectively. The age-adjusted risk ratios for obesity for the lowest level of parental and current education were 1.44 (95% CI 1.32-1.57) and 1.75 (95% CI 1.57-1.95), respectively. Risk of obesity was lowest among those with current education of college graduate, regardless of parental education. Educational level of college graduate may overcome the adverse effects of low parental education on weight gain and obesity risk.

  18. Priority of VHS Development Based in Potential Area using Principal Component Analysis

    NASA Astrophysics Data System (ADS)

    Meirawan, D.; Ana, A.; Saripudin, S.

    2018-02-01

    The current condition of VHS is still inadequate in quality, quantity and relevance. The purpose of this research is to analyse the development of VHS based on the development of regional potential by using principal component analysis (PCA) in Bandung, Indonesia. This study used descriptive qualitative data analysis using the principle of secondary data reduction component. The method used is Principal Component Analysis (PCA) analysis with Minitab Statistics Software tool. The results of this study indicate the value of the lowest requirement is a priority of the construction of development VHS with a program of majors in accordance with the development of regional potential. Based on the PCA score found that the main priority in the development of VHS in Bandung is in Saguling, which has the lowest PCA value of 416.92 in area 1, Cihampelas with the lowest PCA value in region 2 and Padalarang with the lowest PCA value.

  19. Cyclic-nucleotide–gated cation current and Ca2+-activated Cl current elicited by odorant in vertebrate olfactory receptor neurons

    PubMed Central

    Li, Rong-Chang; Ben-Chaim, Yair; Yau, King-Wai; Lin, Chih-Chun

    2016-01-01

    Olfactory transduction in vertebrate olfactory receptor neurons (ORNs) involves primarily a cAMP-signaling cascade that leads to the opening of cyclic-nucleotide–gated (CNG), nonselective cation channels. The consequent Ca2+ influx triggers adaptation but also signal amplification, the latter by opening a Ca2+-activated Cl channel (ANO2) to elicit, unusually, an inward Cl current. Hence the olfactory response has inward CNG and Cl components that are in rapid succession and not easily separable. We report here success in quantitatively separating these two currents with respect to amplitude and time course over a broad range of odorant strengths. Importantly, we found that the Cl current is the predominant component throughout the olfactory dose–response relation, down to the threshold of signaling to the brain. This observation is very surprising given a recent report by others that the olfactory-signal amplification effected by the Ca2+-activated Cl current does not influence the behavioral olfactory threshold in mice. PMID:27647918

  20. Contribution of near-threshold currents to intrinsic oscillatory activity in rat medial entorhinal cortex layer II stellate cells

    PubMed Central

    Boehlen, Anne; Henneberger, Christian; Erchova, Irina

    2013-01-01

    The temporal lobe is well known for its oscillatory activity associated with exploration, navigation, and learning. Intrinsic membrane potential oscillations (MPOs) and resonance of stellate cells (SCs) in layer II of the entorhinal cortex are thought to contribute to network oscillations and thereby to the encoding of spatial information. Generation of both MPOs and resonance relies on the expression of specific voltage-dependent ion currents such as the hyperpolarization-activated cation current (IH), the persistent sodium current (INaP), and the noninactivating muscarine-modulated potassium current (IM). However, the differential contributions of these currents remain a matter of debate. We therefore examined how they modify neuronal excitability near threshold and generation of near-threshold MPOs and resonance in vitro. We found that resonance mainly relied on IH and was reduced by IH blockers and modulated by cAMP and an IM enhancer but that neither of the currents exhibited full control over MPOs in these cells. As previously reported, IH controlled a theta-frequency component of MPOs such that blockade of IH resulted in fewer regular oscillations that retained low-frequency components and high peak amplitude. However, pharmacological inhibition and augmentation of IM also affected MPO frequencies and amplitudes. In contrast to other cell types, inhibition of INaP did not result in suppression of MPOs but only in a moderation of their properties. We reproduced the experimentally observed effects in a single-compartment stochastic model of SCs, providing further insight into the interactions between different ionic conductances. PMID:23076110