Sample records for lpv current control

  1. LPV control for the full region operation of a wind turbine integrated with synchronous generator.

    PubMed

    Cao, Guoyan; Grigoriadis, Karolos M; Nyanteh, Yaw D

    2015-01-01

    Wind turbine conversion systems require feedback control to achieve reliable wind turbine operation and stable current supply. A robust linear parameter varying (LPV) controller is proposed to reduce the structural loads and improve the power extraction of a horizontal axis wind turbine operating in both the partial load and the full load regions. The LPV model is derived from the wind turbine state space models extracted by FAST (fatigue, aerodynamics, structural, and turbulence) code linearization at different operating points. In order to assure a smooth transition between the two regions, appropriate frequency-dependent varying scaling parametric weighting functions are designed in the LPV control structure. The solution of a set of linear matrix inequalities (LMIs) leads to the LPV controller. A synchronous generator model is connected with the closed LPV control loop for examining the electrical subsystem performance obtained by an inner speed control loop. Simulation results of a 1.5 MW horizontal axis wind turbine model on the FAST platform illustrates the benefit of the LPV control and demonstrates the advantages of this proposed LPV controller, when compared with a traditional gain scheduling PI control and prior LPV control configurations. Enhanced structural load mitigation, improved power extraction, and good current performance were obtained from the proposed LPV control.

  2. LPV Control for the Full Region Operation of a Wind Turbine Integrated with Synchronous Generator

    PubMed Central

    Grigoriadis, Karolos M.; Nyanteh, Yaw D.

    2015-01-01

    Wind turbine conversion systems require feedback control to achieve reliable wind turbine operation and stable current supply. A robust linear parameter varying (LPV) controller is proposed to reduce the structural loads and improve the power extraction of a horizontal axis wind turbine operating in both the partial load and the full load regions. The LPV model is derived from the wind turbine state space models extracted by FAST (fatigue, aerodynamics, structural, and turbulence) code linearization at different operating points. In order to assure a smooth transition between the two regions, appropriate frequency-dependent varying scaling parametric weighting functions are designed in the LPV control structure. The solution of a set of linear matrix inequalities (LMIs) leads to the LPV controller. A synchronous generator model is connected with the closed LPV control loop for examining the electrical subsystem performance obtained by an inner speed control loop. Simulation results of a 1.5 MW horizontal axis wind turbine model on the FAST platform illustrates the benefit of the LPV control and demonstrates the advantages of this proposed LPV controller, when compared with a traditional gain scheduling PI control and prior LPV control configurations. Enhanced structural load mitigation, improved power extraction, and good current performance were obtained from the proposed LPV control. PMID:25884036

  3. Switching LPV Control with Double-Layer LPV Model for Aero-Engines

    NASA Astrophysics Data System (ADS)

    Tang, Lili; Huang, Jinquan; Pan, Muxuan

    2017-11-01

    To cover the whole range of operating conditions of aero-engine, a double-layer LPV model is built so as to take into account of the variability due to the flight altitude, Mach number and the rotational speed. With this framework, the problem of designing LPV state-feedback robust controller that guarantees desired bounds on both H_∞ and H_2 performances is considered. Besides this, to reduce the conservativeness caused by a single LPV controller of the whole flight envelope and the common Lyapunov function method, a new method is proposed to design a family of LPV switching controllers. The switching LPV controllers can ensure that the closed-loop system remains stable in the sense of Lyapunov under arbitrary switching logic. Meanwhile, the switching LPV controllers can ensure the parameters change smoothly. The validity and performance of the theoretical results are demonstrated through a numerical example.

  4. LPV Controller Interpolation for Improved Gain-Scheduling Control Performance

    NASA Technical Reports Server (NTRS)

    Wu, Fen; Kim, SungWan

    2002-01-01

    In this paper, a new gain-scheduling control design approach is proposed by combining LPV (linear parameter-varying) control theory with interpolation techniques. The improvement of gain-scheduled controllers can be achieved from local synthesis of Lyapunov functions and continuous construction of a global Lyapunov function by interpolation. It has been shown that this combined LPV control design scheme is capable of improving closed-loop performance derived from local performance improvement. The gain of the LPV controller will also change continuously across parameter space. The advantages of the newly proposed LPV control is demonstrated through a detailed AMB controller design example.

  5. Linear parameter varying representations for nonlinear control design

    NASA Astrophysics Data System (ADS)

    Carter, Lance Huntington

    Linear parameter varying (LPV) systems are investigated as a framework for gain-scheduled control design and optimal hybrid control. An LPV system is defined as a linear system whose dynamics depend upon an a priori unknown but measurable exogenous parameter. A gain-scheduled autopilot design is presented for a bank-to-turn (BTT) missile. The method is novel in that the gain-scheduled design does not involve linearizations about operating points. Instead, the missile dynamics are brought to LPV form via a state transformation. This idea is applied to the design of a coupled longitudinal/lateral BTT missile autopilot. The pitch and yaw/roll dynamics are separately transformed to LPV form, where the cross axis states are treated as "exogenous" parameters. These are actually endogenous variables, so such a plant is called "quasi-LPV." Once in quasi-LPV form, a family of robust controllers using mu synthesis is designed for both the pitch and yaw/roll channels, using angle-of-attack and roll rate as the scheduling variables. The closed-loop time response is simulated using the original nonlinear model and also using perturbed aerodynamic coefficients. Modeling and control of engine idle speed is investigated using LPV methods. It is shown how generalized discrete nonlinear systems may be transformed into quasi-LPV form. A discrete nonlinear engine model is developed and expressed in quasi-LPV form with engine speed as the scheduling variable. An example control design is presented using linear quadratic methods. Simulations are shown comparing the LPV based controller performance to that using PID control. LPV representations are also shown to provide a setting for hybrid systems. A hybrid system is characterized by control inputs consisting of both analog signals and discrete actions. A solution is derived for the optimal control of hybrid systems with generalized cost functions. This is shown to be computationally intensive, so a suboptimal strategy is proposed that neglects a subset of possible parameter trajectories. A computational algorithm is constructed for this suboptimal solution applied to a class of linear non-quadratic cost functions.

  6. Pilot, Randomized Study Assessing Safety, Tolerability and Efficacy of Simplified LPV/r Maintenance Therapy in HIV Patients on the 1st PI-Based Regimen

    PubMed Central

    Cahn, Pedro; Montaner, Julio; Junod, Patrice; Patterson, Patricia; Krolewiecki, Alejandro; Andrade-Villanueva, Jaime; Cassetti, Isabel; Sierra-Madero, Juan; Casiró, Arnaldo David; Bortolozzi, Raul; Lupo, Sergio Horacio; Longo, Nadia; Rampakakis, Emmanouil; Ackad, Nabil; Sampalis, John S.

    2011-01-01

    Objectives To compare the efficacy and safety of an individualized treatment-simplification strategy consisting of switching from a highly-active anti-retroviral treatment (HAART) with a ritonavir-boosted protease inhibitor (PI/r) and 2 nucleoside reverse-transcriptase inhibitors (NRTIs) to lopinavir/ritonavir (LPV/r) monotherapy, with intensification by 2 NRTIs if necessary, to that of continuing their HAART. Methods This is a one-year, randomized, open-label, multi-center study in virologically-suppressed HIV-1-infected adults on their first PI/r-containing treatment, randomized to either LPV/r-monotherapy or continue their current treatment. Treatment efficacy was determined by plasma HIV-1 RNA viral load (VL), time-to-virologic rebound, patient-reported outcomes (PROs) and CD4+T-cell-count changes. Safety was assessed with the incidence of treatment-emergent adverse events (AE). Results Forty-one patients were randomized to LPV/r and 39 to continue their HAART. No statistically-significant differences between the two study groups in demographics and baseline characteristics were observed. At day-360, 71(39:LPV/r;32:HAART) patients completed treatment, while 9(2:LPV/r;7:HAART) discontinued. In a Last Observation Carried Forward Intent-to-Treat analysis, 40(98%) patients on LPV/r and 37(95%) on HAART had VL<200copies/mL (P = 0.61). Time-to-virologic rebound, changes in PROs, CD4+ T-cell-count and VL from baseline, also exhibited no statistically-significant between-group differences. Most frequent AEs were diarrhea (19%), headache (18%) and influenza (16%). Four (10%) patients on LPV/r were intensified with 2 NRTIs, all regaining virologic control. Eight serious AEs were reported by 5(2:LPV/r;3:HAART) patients. Conclusion At day-360, virologic efficacy and safety of LPV/r appears comparable to that of a PI+2NRTIs HAART. These results suggest that our individualized, simplified maintenance strategy with LPV/r-monotherapy and protocol-mandated NRTI re-introduction upon viral rebound, in virologically-suppressed patients merits further prospective long-term evaluation. Trial Registration ClinicalTrials.gov NCT00159224 PMID:21886816

  7. Pilot, randomized study assessing safety, tolerability and efficacy of simplified LPV/r maintenance therapy in HIV patients on the 1 PI-based regimen.

    PubMed

    Cahn, Pedro; Montaner, Julio; Junod, Patrice; Patterson, Patricia; Krolewiecki, Alejandro; Andrade-Villanueva, Jaime; Cassetti, Isabel; Sierra-Madero, Juan; Casiró, Arnaldo David; Bortolozzi, Raul; Lupo, Sergio Horacio; Longo, Nadia; Rampakakis, Emmanouil; Ackad, Nabil; Sampalis, John S

    2011-01-01

    To compare the efficacy and safety of an individualized treatment-simplification strategy consisting of switching from a highly-active anti-retroviral treatment (HAART) with a ritonavir-boosted protease inhibitor (PI/r) and 2 nucleoside reverse-transcriptase inhibitors (NRTIs) to lopinavir/ritonavir (LPV/r) monotherapy, with intensification by 2 NRTIs if necessary, to that of continuing their HAART. This is a one-year, randomized, open-label, multi-center study in virologically-suppressed HIV-1-infected adults on their first PI/r-containing treatment, randomized to either LPV/r-monotherapy or continue their current treatment. Treatment efficacy was determined by plasma HIV-1 RNA viral load (VL), time-to-virologic rebound, patient-reported outcomes (PROs) and CD4+T-cell-count changes. Safety was assessed with the incidence of treatment-emergent adverse events (AE). Forty-one patients were randomized to LPV/r and 39 to continue their HAART. No statistically-significant differences between the two study groups in demographics and baseline characteristics were observed. At day-360, 71(39:LPV/r;32:HAART) patients completed treatment, while 9(2:LPV/r;7:HAART) discontinued. In a Last Observation Carried Forward Intent-to-Treat analysis, 40(98%) patients on LPV/r and 37(95%) on HAART had VL<200 copies/mL (P = 0.61). Time-to-virologic rebound, changes in PROs, CD4+ T-cell-count and VL from baseline, also exhibited no statistically-significant between-group differences. Most frequent AEs were diarrhea (19%), headache (18%) and influenza (16%). Four (10%) patients on LPV/r were intensified with 2 NRTIs, all regaining virologic control. Eight serious AEs were reported by 5(2:LPV/r;3:HAART) patients. At day-360, virologic efficacy and safety of LPV/r appears comparable to that of a PI+2NRTIs HAART. These results suggest that our individualized, simplified maintenance strategy with LPV/r-monotherapy and protocol-mandated NRTI re-introduction upon viral rebound, in virologically-suppressed patients merits further prospective long-term evaluation. ClinicalTrials.gov NCT00159224.

  8. LPV gain-scheduled control of SCR aftertreatment systems

    NASA Astrophysics Data System (ADS)

    Meisami-Azad, Mona; Mohammadpour, Javad; Grigoriadis, Karolos M.; Harold, Michael P.; Franchek, Matthew A.

    2012-01-01

    Hydrocarbons, carbon monoxide and some of other polluting emissions produced by diesel engines are usually lower than those produced by gasoline engines. While great strides have been made in the exhaust aftertreatment of vehicular pollutants, the elimination of nitrogen oxide (NO x ) from diesel vehicles is still a challenge. The primary reason is that diesel combustion is a fuel-lean process, and hence there is significant unreacted oxygen in the exhaust. Selective catalytic reduction (SCR) is a well-developed technology for power plants and has been recently employed for reducing NO x emissions from automotive sources and in particular, heavy-duty diesel engines. In this article, we develop a linear parameter-varying (LPV) feedforward/feedback control design method for the SCR aftertreatment system to decrease NO x emissions while keeping ammonia slippage to a desired low level downstream the catalyst. The performance of the closed-loop system obtained from the interconnection of the SCR system and the output feedback LPV control strategy is then compared with other control design methods including sliding mode, and observer-based static state-feedback parameter-varying control. To reduce the computational complexity involved in the control design process, the number of LPV parameters in the developed quasi-LPV (qLPV) model is reduced by applying the principal component analysis technique. An LPV feedback/feedforward controller is then designed for the qLPV model with reduced number of scheduling parameters. The designed full-order controller is further simplified to a first-order transfer function with a parameter-varying gain and pole. Finally, simulation results using both a low-order model and a high-fidelity and high-order model of SCR reactions in GT-POWER interfaced with MATLAB/SIMULINK illustrate the high NO x conversion efficiency of the closed-loop SCR system using the proposed parameter-varying control law.

  9. LPV Modeling and Control for Active Flutter Suppression of a Smart Airfoil

    NASA Technical Reports Server (NTRS)

    Al-Hajjar, Ali M. H.; Al-Jiboory, Ali Khudhair; Swei, Sean Shan-Min; Zhu, Guoming

    2018-01-01

    In this paper, a novel technique of linear parameter varying (LPV) modeling and control of a smart airfoil for active flutter suppression is proposed, where the smart airfoil has a groove along its chord and contains a moving mass that is used to control the airfoil pitching and plunging motions. The new LPV modeling technique is proposed that uses mass position as a scheduling parameter to describe the physical constraint of the moving mass, in addition the hard constraint at the boundaries is realized by proper selection of the parameter varying function. Therefore, the position of the moving mass and the free stream airspeed are considered the scheduling parameters in the study. A state-feedback based LPV gain-scheduling controller with guaranteed H infinity performance is presented by utilizing the dynamics of the moving mass as scheduling parameter at a given airspeed. The numerical simulations demonstrate the effectiveness of the proposed LPV control architecture by significantly improving the performance while reducing the control effort.

  10. Switching LPV Control for High Performance Tactical Aircraft

    NASA Technical Reports Server (NTRS)

    Lu, Bei; Wu, Fen; Kim, SungWan

    2004-01-01

    This paper examines a switching Linear Parameter-Varying (LPV) control approach to determine if it is practical to use for flight control designs within a wide angle of attack region. The approach is based on multiple parameter-dependent Lyapunov functions. The full parameter space is partitioned into overlapping subspaces and a family of LPV controllers are designed, each suitable for a specific parameter subspace. The hysteresis switching logic is used to accomplish the transition among different parameter subspaces. The proposed switching LPV control scheme is applied to an F-16 aircraft model with different actuator dynamics in low and high angle of attack regions. The nonlinear simulation results show that the aircraft performs well when switching among different angle of attack regions.

  11. Robust Gain-Scheduled Fault Tolerant Control for a Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Shin, Jong-Yeob; Gregory, Irene

    2007-01-01

    This paper presents an application of robust gain-scheduled control concepts using a linear parameter-varying (LPV) control synthesis method to design fault tolerant controllers for a civil transport aircraft. To apply the robust LPV control synthesis method, the nonlinear dynamics must be represented by an LPV model, which is developed using the function substitution method over the entire flight envelope. The developed LPV model associated with the aerodynamic coefficient uncertainties represents nonlinear dynamics including those outside the equilibrium manifold. Passive and active fault tolerant controllers (FTC) are designed for the longitudinal dynamics of the Boeing 747-100/200 aircraft in the presence of elevator failure. Both FTC laws are evaluated in the full nonlinear aircraft simulation in the presence of the elevator fault and the results are compared to show pros and cons of each control law.

  12. Linear-parameter-varying gain-scheduled control of aerospace systems

    NASA Astrophysics Data System (ADS)

    Barker, Jeffrey Michael

    The dynamics of many aerospace systems vary significantly as a function of flight condition. Robust control provides methods of guaranteeing performance and stability goals across flight conditions. In mu-syntthesis, changes to the dynamical system are primarily treated as uncertainty. This method has been successfully applied to many control problems, and here is applied to flutter control. More recently, two techniques for generating robust gain-scheduled controller have been developed. Linear fractional transformation (LFT) gain-scheduled control is an extension of mu-synthesis in which the plant and controller are explicit functions of parameters measurable in real-time. This LFT gain-scheduled control technique is applied to the Benchmark Active Control Technology (BACT) wing, and compared with mu-synthesis control. Linear parameter-varying (LPV) gain-scheduled control is an extension of Hinfinity control to parameter varying systems. LPV gain-scheduled control directly incorporates bounds on the rate of change of the scheduling parameters, and often reduces conservatism inherent in LFT gain-scheduled control. Gain-scheduled LPV control of the BACT wing compares very favorably with the LFT controller. Gain-scheduled LPV controllers are generated for the lateral-directional and longitudinal axes of the Innovative Control Effectors (ICE) aircraft and implemented in nonlinear simulations and real-time piloted nonlinear simulations. Cooper-Harper and pilot-induced oscillation ratings were obtained for an initial design, a reference aircraft and a redesign. Piloted simulation results for the initial LPV gain-scheduled control of the ICE aircraft are compared with results for a conventional fighter aircraft in discrete pitch and roll angle tracking tasks. The results for the redesigned controller are significantly better than both the previous LPV controller and the conventional aircraft.

  13. Quasi-Linear Parameter Varying Representation of General Aircraft Dynamics Over Non-Trim Region

    NASA Technical Reports Server (NTRS)

    Shin, Jong-Yeob

    2007-01-01

    For applying linear parameter varying (LPV) control synthesis and analysis to a nonlinear system, it is required that a nonlinear system be represented in the form of an LPV model. In this paper, a new representation method is developed to construct an LPV model from a nonlinear mathematical model without the restriction that an operating point must be in the neighborhood of equilibrium points. An LPV model constructed by the new method preserves local stabilities of the original nonlinear system at "frozen" scheduling parameters and also represents the original nonlinear dynamics of a system over a non-trim region. An LPV model of the motion of FASER (Free-flying Aircraft for Subscale Experimental Research) is constructed by the new method.

  14. Pentavalent vaccine and adverse events following immunization-untangling the misinterpretations.

    PubMed

    Malik, Akash

    2014-12-01

    In April 2008, the National Technical Group on Immunization (NTAGI) Sub-committee on H. influenza type b (Hib) vaccine recommended that Hib containing pentavalent vaccine should be introduced in the country. Subsequently liquid pentavalent vaccine (LPV) was launched in the Kerala and Tamil Nadu on a pilot basis in December 2011. The introduction of LPV in these two states was followed by reported deaths in infants who had received LPV. An exhaustive summary of media reports and previous literature has since been made available at various fora which have been supplemented with estimations of the damage the LPV may cause. It has thus been concluded that the LPV is bound to cause more number of infant deaths than it will save from Hib meningitis and pneumonia. The current paper aims to clear some of the misinterpretations and miscalculations so that lives of 72,000 infants can be saved.

  15. Design of LPV fault-tolerant controller for pitch system of wind turbine

    NASA Astrophysics Data System (ADS)

    Wu, Dinghui; Zhang, Xiaolin

    2017-07-01

    To address failures of wind turbine pitch-angle sensors, traditional wind turbine linear parameter varying (LPV) model is transformed into a double-layer convex polyhedron LPV model. On the basis of this model, when the plurality of the sensor undergoes failure and details of the failure are inconvenient to obtain, each sub-controller is designed using distributed thought and gain scheduling method. The final controller is obtained using all of the sub-controllers by a convex combination. The design method corrects the errors of the linear model, improves the linear degree of the system, and solves the problem of multiple pitch angle faults to ensure stable operation of the wind turbine.

  16. Linear Parameter Varying Control Synthesis for Actuator Failure, Based on Estimated Parameter

    NASA Technical Reports Server (NTRS)

    Shin, Jong-Yeob; Wu, N. Eva; Belcastro, Christine

    2002-01-01

    The design of a linear parameter varying (LPV) controller for an aircraft at actuator failure cases is presented. The controller synthesis for actuator failure cases is formulated into linear matrix inequality (LMI) optimizations based on an estimated failure parameter with pre-defined estimation error bounds. The inherent conservatism of an LPV control synthesis methodology is reduced using a scaling factor on the uncertainty block which represents estimated parameter uncertainties. The fault parameter is estimated using the two-stage Kalman filter. The simulation results of the designed LPV controller for a HiMXT (Highly Maneuverable Aircraft Technology) vehicle with the on-line estimator show that the desired performance and robustness objectives are achieved for actuator failure cases.

  17. Switching State-Feedback LPV Control with Uncertain Scheduling Parameters

    NASA Technical Reports Server (NTRS)

    He, Tianyi; Al-Jiboory, Ali Khudhair; Swei, Sean Shan-Min; Zhu, Guoming G.

    2017-01-01

    This paper presents a new method to design Robust Switching State-Feedback Gain-Scheduling (RSSFGS) controllers for Linear Parameter Varying (LPV) systems with uncertain scheduling parameters. The domain of scheduling parameters are divided into several overlapped subregions to undergo hysteresis switching among a family of simultaneously designed LPV controllers over the corresponding subregion with the guaranteed H-infinity performance. The synthesis conditions are given in terms of Parameterized Linear Matrix Inequalities that guarantee both stability and performance at each subregion and associated switching surfaces. The switching stability is ensured by descent parameter-dependent Lyapunov function on switching surfaces. By solving the optimization problem, RSSFGS controller can be obtained for each subregion. A numerical example is given to illustrate the effectiveness of the proposed approach over the non-switching controllers.

  18. [Lopinavir/ritonavir in patients with human immunodeficiency virus infection in special situations].

    PubMed

    Tasias, María; Aldeguer, José López

    2014-11-01

    Ritonavir-boosted lopinavir (LPV/r) is a protease inhibitor used for the treatment of human immunodeficiency virus (HIV) infection in both normal patients and in certain situations. In patients with renal failure, LPV/r does not require dosage adjustment because it is metabolized in the liver. Cohort studies have shown that the incidence of varying degrees of renal disease and/or crystalluria related to combination antiretroviral therapy with tenofovir and some protease inhibitors (PI) does not appear with LPV/r or that the incidence is much lower with this combination. Neurocognitive impairments are described in a high proportion of patients with HIV infection and viral replication or related inflammatory activity in the subarachnoid space. In these patients, LPV/r is one of the therapeutic options. A score has been published that rates antiretroviral drugs according to the concentration attained in the cerebrospinal fluid (CSF). LPV/r levels reached in CSF exceed the IC50 of wild-type HIV and has a valuable score (score 3) of the drugs currently used. The most important comorbid condition is chronic hepatitis, due to its frequency and because the biotransformation of LPV/r occurs in the liver. In these circumstances, it is important to evaluate the influence of liver failure on blood drug levels and how these values may cause liver toxicity. LPV/r dose modification has not been established in the presence of liver failure. LPV/r-induced liver toxicity has only been reported with a certain frequency when liver enzymes were elevated at baseline or in patients with chronic hepatitis C, although most cases of liver toxicity were mild. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  19. Gain-scheduling multivariable LPV control of an irrigation canal system.

    PubMed

    Bolea, Yolanda; Puig, Vicenç

    2016-07-01

    The purpose of this paper is to present a multivariable linear parameter varying (LPV) controller with a gain scheduling Smith Predictor (SP) scheme applicable to open-flow canal systems. This LPV controller based on SP is designed taking into account the uncertainty in the estimation of delay and the variation of plant parameters according to the operating point. This new methodology can be applied to a class of delay systems that can be represented by a set of models that can be factorized into a rational multivariable model in series with left/right diagonal (multiple) delays, such as, the case of irrigation canals. A multiple pool canal system is used to test and validate the proposed control approach. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  20. A hybrid design to optimize preparation of lopinavir loaded solid lipid nanoparticles and comparative pharmacokinetic evaluation with marketed lopinavir/ritonavir coformulation.

    PubMed

    Ravi, Punna Rao; Vats, Rahul; Dalal, Vikas; Murthy, Aditya Narasimha

    2014-07-01

    To prepare stearic acid-based lopinavir (LPV) loaded solid lipid nanoparticles (SLNs) using a hybrid design and compare in-vivo performance of optimized formulation with marketed LPV/ritonavir (RTV) coformulation. LPV SLNs were prepared by hot melt emulsion technique and optimized using Plackett-Burman design and Box-Behnken design. Physical characterization studies were conducted for the optimized SLNs. Comparative oral pharmacokinetic studies and tissue distribution studies of optimized SLNs and LPV/RTV coformulation were done in Wistar rats. In-vitro metabolic stability and intestinal permeability studies for LPV SLNs were undertaken to elucidate the mechanism involved in the pharmacokinetic improvement of LPV. Optimized SLNs exhibited nanometeric size (223 nm) with high entrapment efficiency (83%). In-vitro drug release study of SLNs showed biphasic sustained release behaviour. Significant increase in oral bioavailability of LPV from LPV SLNs (5 folds) and LPV/RTV coformulation (3.7 folds) was observed as compared with free LPV. LPV SLNs showed better tissue distribution of LPV in HIV reservoirs than LPV/RTV coformulation. In-vitro studies demonstrated that SLNs provided metabolic protection of LPV and were endocytosized during absorption. SLNs enhanced oral bioavailability and improved distribution profile of LPV to HIV reservoirs and hence could be better alternative to LPV/RTV coformulation. © 2014 Royal Pharmaceutical Society.

  1. Economic and health-related quality-of-life (HRQoL) comparison of lopinavir/ritonavir (LPV/r) and atazanavir plus ritonavir (ATV+RTV) based regimens for antiretroviral therapy (ART)-naïve and -experienced United Kingdom patients in 2011.

    PubMed

    Simpson, K N; Baran, R W; Collomb, D; Beck, E J; Van de Steen, O; Dietz, B

    2012-01-01

    Using a United Kingdom (UK)-based National Health Services perspective for 2011 this study first estimated the cost-effectiveness and budget impact implications for lopinavir/ritonavir (LPV/r) vs atazanavir plus ritonavir (ATV+RTV) treatment of antiretroviral therapy (ART)-naïve patients and secondly examined the long-term health-related quality-of-life (HRQoL) and economic implications for LPV/r vs ATV+RTV treatment of ART-experienced patients. A previously published Markov model that integrates epidemiological data of human immunodeficiency virus (HIV) with predictors of coronary heart disease (CHD) was modified under a clearly specified set of assumptions to reflect viral load (VL) suppression profiles and other differences for these two regimens, applying results from the CASTLE study in ART-naïve patients and using data from BMS-045 in ART-experienced patients. ART costs were referenced to current (2011) pricing guidelines in the UK. Medical care costs reflected UK treatment patterns and relevant drug pricing. Costs and outcomes were discounted at 3.5% per year. Costs are expressed in British pounds (£) and life expectancy in quality-adjusted life years (QALYs). In the ART-naïve subjects, the model predicted a marginal improved life expectancy of 0.031 QALYs (11 days) for the ATV+RTV regimen as a result of predicted CHD outcomes based on lower increases in cholesterol levels compared with the LPV/r regimen. The model demonstrated cost savings with the LPV/r regimen. The total lifetime cost savings was £4070 per patient for the LPV/r regimen. LPV/r saved £2133 and £3409 per patient at 5 and 10 years, respectively. Referenced to LPV/r, the incremental cost-effectiveness ratio (ICER) for ATV+RTV was £149,270/QALY. For ART-experienced patients VL suppression differences favored LPV/r, while CHD risk associated with elevated total cholesterol marginally favored ATV+RTV, resulting in a net improvement in life expectancy of 0.31 QALYs (106 days) for LPV/r. Five-year costs were £5538 per patient greater for ATV+RTV, with a discounted lifetime saving of £1445 per LPV/r patient. LPV/r was modestly dominant economically, producing better outcomes and cost savings. The limitations of this study include uncertainty related to how well the model's assumptions capture current practice, as well as the validity of the model parameters used. This study was limited to using aggregated data in the public domain from the two clinical trials. Thus, some of the model parameters may reflect limitations due to trial design and data aggregation bias. This study has attempted to illuminate the effect of these limitations by presenting the results of the comprehensive sensitivity analysis. Based on 2011 costs of HIV in the UK and the published efficacy data from the CASTLE and BMS-045 studies, ATV+RTV-based regimens are not expected to be a cost-effective use of resources for ART-naïve patients similar to patients in the CASTLE study, nor for ART-experienced patients based on the only published comparison of ATV+RTV and LPV/r.

  2. Observer-based H∞ resilient control for a class of switched LPV systems and its application

    NASA Astrophysics Data System (ADS)

    Yang, Dong; Zhao, Jun

    2016-11-01

    This paper deals with the issue of observer-based H∞ resilient control for a class of switched linear parameter-varying (LPV) systems by utilising a multiple parameter-dependent Lyapunov functions method. First, attention is focused upon the design of a resilient observer, an observer-based resilient controller and a parameter and estimate state-dependent switching signal, which can stabilise and achieve the disturbance attenuation for the given systems. Then, a solvability condition of the H∞ resilient control problem is given in terms of matrix inequality for the switched LPV systems. This condition allows the H∞ resilient control problem for each individual subsystem to be unsolvable. The observer, controller, and switching signal are explicitly computed by solving linear matrix inequalities (LMIs). Finally, the effectiveness of the proposed control scheme is illustrated by its application to a turbofan engine, which can hardly be handled by the existing approaches.

  3. Nonlinear control of linear parameter varying systems with applications to hypersonic vehicles

    NASA Astrophysics Data System (ADS)

    Wilcox, Zachary Donald

    The focus of this dissertation is to design a controller for linear parameter varying (LPV) systems, apply it specifically to air-breathing hypersonic vehicles, and examine the interplay between control performance and the structural dynamics design. Specifically a Lyapunov-based continuous robust controller is developed that yields exponential tracking of a reference model, despite the presence of bounded, nonvanishing disturbances. The hypersonic vehicle has time varying parameters, specifically temperature profiles, and its dynamics can be reduced to an LPV system with additive disturbances. Since the HSV can be modeled as an LPV system the proposed control design is directly applicable. The control performance is directly examined through simulations. A wide variety of applications exist that can be effectively modeled as LPV systems. In particular, flight systems have historically been modeled as LPV systems and associated control tools have been applied such as gain-scheduling, linear matrix inequalities (LMIs), linear fractional transformations (LFT), and mu-types. However, as the type of flight environments and trajectories become more demanding, the traditional LPV controllers may no longer be sufficient. In particular, hypersonic flight vehicles (HSVs) present an inherently difficult problem because of the nonlinear aerothermoelastic coupling effects in the dynamics. HSV flight conditions produce temperature variations that can alter both the structural dynamics and flight dynamics. Starting with the full nonlinear dynamics, the aerothermoelastic effects are modeled by a temperature dependent, parameter varying state-space representation with added disturbances. The model includes an uncertain parameter varying state matrix, an uncertain parameter varying non-square (column deficient) input matrix, and an additive bounded disturbance. In this dissertation, a robust dynamic controller is formulated for a uncertain and disturbed LPV system. The developed controller is then applied to a HSV model, and a Lyapunov analysis is used to prove global exponential reference model tracking in the presence of uncertainty in the state and input matrices and exogenous disturbances. Simulations with a spectrum of gains and temperature profiles on the full nonlinear dynamic model of the HSV is used to illustrate the performance and robustness of the developed controller. In addition, this work considers how the performance of the developed controller varies over a wide variety of control gains and temperature profiles and are optimized with respect to different performance metrics. Specifically, various temperature profile models and related nonlinear temperature dependent disturbances are used to characterize the relative control performance and effort for each model. Examining such metrics as a function of temperature provides a potential inroad to examine the interplay between structural/thermal protection design and control development and has application for future HSV design and control implementation.

  4. Robust synergetic control design under inputs and states constraints

    NASA Astrophysics Data System (ADS)

    Rastegar, Saeid; Araújo, Rui; Sadati, Jalil

    2018-03-01

    In this paper, a novel robust-constrained control methodology for discrete-time linear parameter-varying (DT-LPV) systems is proposed based on a synergetic control theory (SCT) approach. It is shown that in DT-LPV systems without uncertainty, and for any unmeasured bounded additive disturbance, the proposed controller accomplishes the goal of stabilising the system by asymptotically driving the error of the controlled variable to a bounded set containing the origin and then maintaining it there. Moreover, given an uncertain DT-LPV system jointly subject to unmeasured and constrained additive disturbances, and constraints in states, input commands and reference signals (set points), then invariant set theory is used to find an appropriate polyhedral robust invariant region in which the proposed control framework is guaranteed to robustly stabilise the closed-loop system. Furthermore, this is achieved even for the case of varying non-zero control set points in such uncertain DT-LPV systems. The controller is characterised to have a simple structure leading to an easy implementation, and a non-complex design process. The effectiveness of the proposed method and the implications of the controller design on feasibility and closed-loop performance are demonstrated through application examples on the temperature control on a continuous-stirred tank reactor plant, on the control of a real-coupled DC motor plant, and on an open-loop unstable system example.

  5. Anti-HIV drugs, lopinavir/ritonavir and atazanavir, modulate innate immune response triggered by Leishmania in macrophages: the role of NF-κB and PPAR-γ.

    PubMed

    Alves, Érica Alessandra Rocha; de Miranda, Marthina Gomes; Borges, Tatiana Karla; Magalhães, Kelly Grace; Muniz-Junqueira, Maria Imaculada

    2015-02-01

    This study evaluated the influence of HIV protease inhibitors lopinavir/ritonavir (LPV/RTV) and atazanavir (ATV) on macrophage functions during their first interaction with Leishmania. Macrophages from BALB/c mice treated for 10days with LPV/RTV and ATV, infected or not in vitro with L. (L.) amazonensis, were used to investigate the effects of these drugs on infection index, leishmanicidal capacity, cytokine production and PPAR-γ and RelB expression. LPV/RTV and ATV treatments significantly increased the infection index and the percentage of Leishmania-infected macrophages compared to untreated infected macrophages. There was no correlated increase in the production of NO and H2O2 leishmanicidal molecules. Promastigotes derived from Leishmania-infected macrophages from LPV/RTV and ATV-treated BALB/c mice had an in vitro growth 45.1% and 56.4% higher in groups treated with LPV/RTV and ATV than with PBS in culture. ATV treatment reduced IL-12p70 and IL-10 secretion in Leishmania-infected macrophages, but had no effect on IL-23 and TNF production. LPV reduced IL-10 and had no effect on IL-12p70, TNF and IL-23 secretion. ATV treatment decreased PPAR-γ expression in Leishmania-infected macrophages compared to untreated infected macrophages. In addition, LPV/RTV, but not ATV, reduced RelB cytoplasm-to-nucleus translocation in Leishmania-infected macrophages. Results showed that LPV/RTV and ATV HIV protease inhibitors were able to modulate innate defense mechanisms against Leishmania via different intracellular pathways. Although HIV protease inhibitors are highly efficient to control the Human Immunodeficiency Virus, these drugs might also influence the course of leishmaniasis in HIV-Leishmania-co-infected individuals. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Robust Nonlinear Feedback Control of Aircraft Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Garrard, William L.; Balas, Gary J.; Litt, Jonathan (Technical Monitor)

    2001-01-01

    This is the final report on the research performed under NASA Glen grant NASA/NAG-3-1975 concerning feedback control of the Pratt & Whitney (PW) STF 952, a twin spool, mixed flow, after burning turbofan engine. The research focussed on the design of linear and gain-scheduled, multivariable inner-loop controllers for the PW turbofan engine using H-infinity and linear, parameter-varying (LPV) control techniques. The nonlinear turbofan engine simulation was provided by PW within the NASA Rocket Engine Transient Simulator (ROCETS) simulation software environment. ROCETS was used to generate linearized models of the turbofan engine for control design and analysis as well as the simulation environment to evaluate the performance and robustness of the controllers. Comparison between the H-infinity, and LPV controllers are made with the baseline multivariable controller and developed by Pratt & Whitney engineers included in the ROCETS simulation. Simulation results indicate that H-infinity and LPV techniques effectively achieve desired response characteristics with minimal cross coupling between commanded values and are very robust to unmodeled dynamics and sensor noise.

  7. Population approach to analyze the pharmacokinetics of free and total lopinavir in HIV-infected pregnant women and consequences for dose adjustment.

    PubMed

    Fauchet, Floris; Treluyer, Jean-Marc; Illamola, Silvia M; Pressiat, Claire; Lui, Gabrielle; Valade, Elodie; Mandelbrot, Laurent; Lechedanec, Jerome; Delmas, Sandrine; Blanche, Stéphane; Warszawski, Josiane; Urien, Saik; Tubiana, Roland; Hirt, Déborah

    2015-09-01

    The aims of this study were to describe the unbound and total lopinavir (LPV) pharmacokinetics in pregnant women in order to evaluate if a dosing adjustment is necessary during pregnancy. Lopinavir placental transfer is described, and several genetic covariates were tested to explain its variability. A total of 400 maternal, 79 cord blood, and 48 amniotic fluid samples were collected from 208 women for LPV concentration determinations and pharmacokinetics analysis. Among the maternal LPV concentrations, 79 samples were also used to measure the unbound LPV concentrations. Population pharmacokinetics models were developed by using NONMEM software. Two models were developed to describe (i) unbound and total LPV pharmacokinetics and (ii) LPV placental transfer. The pharmacokinetics was best described by a one-compartment model with first-order absorption and elimination. A pregnancy effect was found on maternal clearance (39% increase), whereas the treatment group (monotherapy versus triple therapy) or the genetic polymorphisms did not explain the pharmacokinetics or placental transfer of LPV. Efficient unbound LPV concentrations in nonpregnant women were similar to those measured during the third trimester of pregnancy. Our study showed a 39% increase of maternal total LPV clearance during pregnancy, whereas unbound LPV concentrations were similar to those simulated in nonpregnant women. The genetic polymorphisms selected did not influence the LPV pharmacokinetics or placental transfer. Thus, we suggest that the LPV dosage should not be increased during pregnancy. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  8. Population Approach To Analyze the Pharmacokinetics of Free and Total Lopinavir in HIV-Infected Pregnant Women and Consequences for Dose Adjustment

    PubMed Central

    Treluyer, Jean-Marc; Illamola, Silvia M.; Pressiat, Claire; Lui, Gabrielle; Valade, Elodie; Mandelbrot, Laurent; Lechedanec, Jerome; Delmas, Sandrine; Blanche, Stéphane; Warszawski, Josiane; Urien, Saik; Tubiana, Roland; Hirt, Déborah

    2015-01-01

    The aims of this study were to describe the unbound and total lopinavir (LPV) pharmacokinetics in pregnant women in order to evaluate if a dosing adjustment is necessary during pregnancy. Lopinavir placental transfer is described, and several genetic covariates were tested to explain its variability. A total of 400 maternal, 79 cord blood, and 48 amniotic fluid samples were collected from 208 women for LPV concentration determinations and pharmacokinetics analysis. Among the maternal LPV concentrations, 79 samples were also used to measure the unbound LPV concentrations. Population pharmacokinetics models were developed by using NONMEM software. Two models were developed to describe (i) unbound and total LPV pharmacokinetics and (ii) LPV placental transfer. The pharmacokinetics was best described by a one-compartment model with first-order absorption and elimination. A pregnancy effect was found on maternal clearance (39% increase), whereas the treatment group (monotherapy versus triple therapy) or the genetic polymorphisms did not explain the pharmacokinetics or placental transfer of LPV. Efficient unbound LPV concentrations in nonpregnant women were similar to those measured during the third trimester of pregnancy. Our study showed a 39% increase of maternal total LPV clearance during pregnancy, whereas unbound LPV concentrations were similar to those simulated in nonpregnant women. The genetic polymorphisms selected did not influence the LPV pharmacokinetics or placental transfer. Thus, we suggest that the LPV dosage should not be increased during pregnancy. PMID:26149996

  9. Pharmacokinetics of Lopinavir in HIV-Infected Adults Receiving Rifampin with Adjusted Doses of Lopinavir-Ritonavir Tablets▿

    PubMed Central

    Decloedt, Eric H.; McIlleron, Helen; Smith, Peter; Merry, Concepta; Orrell, Catherine; Maartens, Gary

    2011-01-01

    Rifampin coadministration dramatically reduces plasma lopinavir (LPV) concentrations. In healthy volunteers, doubling the dose of a lopinavir-ritonavir (LPV/r) capsule formulation overcame this interaction, but a subsequent study of double doses of the tablet formulation was stopped early owing to hepatotoxicity. However, healthy-volunteer study findings may not apply to HIV-infected adults. We evaluated the steady-state pharmacokinetics of LPV in HIV-infected adults virologically suppressed on an LPV/r regimen who were given rifampin, and the dose of the LPV/r tablet formulation was gradually increased. The steady-state pharmacokinetics of LPV/r were evaluated at baseline, a week after commencing rifampin, a week after the LPV/r dose was increased 1.5 times, and a week after the LPV/r dose was doubled. Twenty-one participants were enrolled. The median [interquartile range (IQR)] predose LPV concentrations (C0) were 8.1 (6.2 to 9.8) mg/liter at baseline, 1.7 (0.3 to 3.0) mg/liter after 7 days of rifampin, 5.9 (2.1 to 9.9) mg/liter with 1.5 times the dose of LPV/r, and 10.8 (7.0 to 13.1) mg/liter with double-dose LPV/r. There were no significant differences in the LPV area under the plasma concentration-time curve from 0 to 12 h (AUC0-12), C0, C12, maximum concentration of drug in serum (Cmax), or half-life (t1/2) between the baseline and double-dose LPV/r time points. Treatment was generally well tolerated, with two participants developing asymptomatic grade 3/4 transaminitis. Doubling the dose of the tablet formulation of LPV/r overcomes induction by rifampin. Less hepatotoxicity occurred in our cohort of HIV-infected participants than was reported in healthy-volunteer studies. PMID:21537021

  10. Linear Parameter Varying Control for Actuator Failure

    NASA Technical Reports Server (NTRS)

    Shin, Jong-Yeob; Wu, N. Eva; Belcastro, Christine; Bushnell, Dennis M. (Technical Monitor)

    2002-01-01

    A robust linear parameter varying (LPV) control synthesis is carried out for an HiMAT vehicle subject to loss of control effectiveness. The scheduling parameter is selected to be a function of the estimates of the control effectiveness factors. The estimates are provided on-line by a two-stage Kalman estimator. The inherent conservatism of the LPV design is reducing through the use of a scaling factor on the uncertainty block that represents the estimation errors of the effectiveness factors. Simulations of the controlled system with the on-line estimator show that a superior fault-tolerance can be achieved.

  11. Reducing Glucose Variability Due to Meals and Postprandial Exercise in T1DM Using Switched LPV Control: In Silico Studies.

    PubMed

    Colmegna, Patricio H; Sánchez-Peña, Ricardo S; Gondhalekar, Ravi; Dassau, Eyal; Doyle, Francis J

    2016-05-01

    Time-varying dynamics is one of the main issues for achieving safe blood glucose control in type 1 diabetes mellitus (T1DM) patients. In addition, the typical disturbances considered for controller design are meals, which increase the glucose level, and physical activity (PA), which increases the subject's sensitivity to insulin. In previous works the authors have applied a linear parameter-varying (LPV) control technique to manage unannounced meals. A switched LPV controller that switches between 3 LPV controllers, each with a different level of aggressiveness, is designed to further cope with both unannounced meals and postprandial PA. Thus, the proposed control strategy has a "standard" mode, an "aggressive" mode, and a "conservative" mode. The "standard" mode is designed to be applied most of the time, while the "aggressive" mode is designed to deal only with hyperglycemia situations. On the other hand, the "conservative" mode is focused on postprandial PA control. An ad hoc simulator has been developed to test the proposed controller. This simulator is based on the distribution version of the UVA/Padova model and includes the effect of PA based on Schiavon.(1) The test results obtained when using this simulator indicate that the proposed control law substantially reduces the risk of hypoglycemia with the conservative strategy, while the risk of hyperglycemia is scarcely affected. It is demonstrated that the announcement, or anticipation, of exercise is indispensable for letting a mono-hormonal artificial pancreas deal with the consequences of postprandial PA. In view of this the proposed controller allows switching into a conservative mode when notified of PA by the user. © 2016 Diabetes Technology Society.

  12. Virological Efficacy in Cerebrospinal Fluid and Neurocognitive Status in Patients with Long-Term Monotherapy Based on Lopinavir/Ritonavir: An Exploratory Study

    PubMed Central

    Santos, José R.; Muñoz-Moreno, José A.; Moltó, José; Prats, Anna; Curran, Adrià; Domingo, Pere; Llibre, Josep M.; McClernon, Daniel R.; Bravo, Isabel; Canet, Jaume; Watson, Victoria; Back, David; Clotet, Bonaventura

    2013-01-01

    Background Data on suppression of HIV replication in the CNS and on the subsequent risk of neurocognitive impairment using monotherapy with boosted protease inhibitors are limited. Methods Ours was an exploratory cross-sectional study in patients on lopinavir/ritonavir-based monotherapy (LPV/r-MT) or standard triple therapy (LPV/r-ART) for at least 96 weeks who maintained a plasma viral load <50 copies/mL. HIV-1 RNA in CSF was determined by HIV-1 SuperLow assay (lower limit of detection, 1 copy/mL). Neurocognitive functioning was assessed using a recommended battery of neuropsychological tests covering 7 areas. Neurocognitive impairment (NCI) was determined and also a global deficit score (GDS) for study comparisons. Results Seventeen patients on LPV/r-MT and 17 on LPV/r-ART were included. Fourteen (82.4%) patients on LPV/r-MT and 16 (94.1%) on LPV/r-ART had HIV-1 RNA <1 copy/mL in CSF (p = 0.601). NCI was observed in 7 patients on LPV/r-MT and in 10 on LPV/r-ART (41% vs 59%; p = 0.494). Mean (SD) GDS was 0.22 (0.20) in patients on LPV/r-MT and 0.47 (0.34) in those on LPV/r-ART (p = 0.012). Conclusions Suppression of HIV in CSF is similar in individuals with durable plasma HIV-1 RNA suppression who are receiving LPV/r-MT or LPV/r-ART for at least 96 weeks. Findings for HIV-1 replication in CSF and neurocognitive status indicate that this strategy seems to be safe for CNS functioning. PMID:23922957

  13. On the Numerical Formulation of Parametric Linear Fractional Transformation (LFT) Uncertainty Models for Multivariate Matrix Polynomial Problems

    NASA Technical Reports Server (NTRS)

    Belcastro, Christine M.

    1998-01-01

    Robust control system analysis and design is based on an uncertainty description, called a linear fractional transformation (LFT), which separates the uncertain (or varying) part of the system from the nominal system. These models are also useful in the design of gain-scheduled control systems based on Linear Parameter Varying (LPV) methods. Low-order LFT models are difficult to form for problems involving nonlinear parameter variations. This paper presents a numerical computational method for constructing and LFT model for a given LPV model. The method is developed for multivariate polynomial problems, and uses simple matrix computations to obtain an exact low-order LFT representation of the given LPV system without the use of model reduction. Although the method is developed for multivariate polynomial problems, multivariate rational problems can also be solved using this method by reformulating the rational problem into a polynomial form.

  14. A simple HPLC method for simultaneous determination of lopinavir, ritonavir and efavirenz.

    PubMed

    Usami, Yoshiko; Oki, Tsuyoshi; Nakai, Masahiko; Sagisaka, Masafumi; Kaneda, Tsuguhiro

    2003-06-01

    We developed a simple HPLC method for the simultaneous determination of lopinavir (LPV), ritonavir (RTV) and efavirenz (EFV) to evaluate the efficiency of co-administration of LPV/RTV and EFV in Japanese patients enrolled in a clinical study. The monitoring of LPV plasma concentration is important because co-administration of LPV/RTV with EFV sometimes decreases plasma concentrations of LPV caused by EFV activation of cytochrome P-450 3A. A solution of acetonitrile, methanol and tetramethylammonium perchlorate (TMAP) in dilute aqueous trifluoroacetic acid (TFA) has been used as the mobile phase in a HPLC method to elute LPV and RTV. We found that a solvent ratio of 45 : 5 : 50 (v/v/v) of acetonitrile/methanol/0.02 M TMAP in 0.2% TFA optimized separation of LPV, RTV and EFV. A column temperature of 30 degrees C was necessary for the reproducibility of the analyses. Standard curves were linear in the range 0.060 to 24.06 micro g/ml for LPV, 0.010 to 4.16 micro g/ml for RTV, and 0.047 to 37.44 micro g/ml for EFV. Coefficients of variation (CVs) of LPV, RTV and EFV in intraday and interday assays ranged from 1.5 to 4.0%, 2.5 to 16.8% and 1.0 to 7.7%, respectively. Accuracies ranged from 100 to 110%, 101 to 116% and 99 to 106% for LPV, RTV and EFV, respectively. The extraction recoveries were 77-87, 77-83 and 81-91% for LPV, RTV and EFV, respectively.

  15. [Monotherapy in treatment-naïve patients].

    PubMed

    Arranz Caso, José Alberto

    2008-12-01

    The development of antiretroviral therapy (ART) with current triple drug combinations has dramatically reduced morbidity and mortality in HIV-infected patients. However, there is a need for less toxic treatments without sacrificing efficacy, as well as for less expensive drugs to facilitate universal access to this therapy. The protease inhibitors (PI) administered with ritonavir have a favorable pharmacokinetic profile and high genetic barrier and consequently are ideal candidates for use in monotherapy, thus avoiding the toxicity and cost associated with nucleoside analogs, as well as preserving drugs for future options. The promising results of studies performed with lopinavir/ritonavir (LPV/r) in induction-maintenance regimens in patients without prior failure to PIs encourage research into the cost-effectiveness of LPV/r in monotherapy from the beginning of ART. The few studies performed in this context seem to indicate the following: a) LPV/r monotherapy achieves undetectable viral loads in a large proportion of treatment-naïve patients, b) future treatment options are not compromised in patients not achieving undetectable viral loads since the likelihood of resistance mutations is low and treatment intensification achieves suppression of viral replication, and c) strategies for early detection can probably be considered in patients who will not achieve complete suppression with LPV/r monotherapy. Nevertheless, before LPV/r monotherapy can be considered a first-line option, new studies with larger samples and longer follow-up are required. These studies should pay particular attention to viral replication in areas where PI show less penetration.

  16. Land Product Validation (LPV)

    NASA Technical Reports Server (NTRS)

    Schaepman, Gabriela; Roman, Miguel O.

    2013-01-01

    This presentation will discuss Land Product Validation (LPV) objectives and goals, LPV structure update, interactions with other initiatives during report period, outreach to the science community, future meetings and next steps.

  17. Plasma metabolic changes in Chinese HIV-infected patients receiving lopinavir/ritonavir based treatment: Implications for HIV precision therapy.

    PubMed

    Li, Xiaolin; Wu, Tong; Jiang, Yongjun; Zhang, Zining; Han, Xiaoxu; Geng, Wenqing; Ding, Haibo; Kang, Jing; Wang, Qi; Shang, Hong

    2018-05-16

    The goal of this study is to profile the metabolic changes in the plasma of HIV patients receiving lopinavir/ritonavir (LPV/r)-based highly active antiretroviral therapy (HAART) relative to their treatment-naïve phase, aimed to identify precision therapy for HIV for improving prognosis and predicting dyslipidemia caused by LPV/r. 38 longitudinal plasma samples were collected from 19 HIV-infected patients both before and after antiretroviral therapy, and 18 samples from healthy individuals were used as controls. Untargeted metabolomics profiling of these plasma samples was performed using liquid chromatography-mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS). A total of 331 compounds of known identity were detected among these metabolites, a 67-metabolite signature mainly mapping to tryptophan, histidine, acyl carnitine, ketone bodies and fatty acid metabolism distinguished HIV patients from healthy controls. The levels of 19 out of the 67 altered metabolites including histidine, kynurenine, and 3-hydroxybutyrate (BHBA), recovered after LPV/r-based antiretroviral therapy, and histidine was positively correlated with the presence of CD4 + T lymphocytes. Furthermore, using receiver operating characteristic (ROC) analyses, we discovered that butyrylcarnitine in combination with myristic acid from plasma in treatment-naïve patients could predict dyslipidemia caused by LPV/r with 87% accuracy. Metabolites alterations in treatment-naïve HIV patients may indicate an inflammatory, oxidative state and mitochondrial dysfunction that is permissive for disease progression. Histidine may provide a specific protective function for HIV patients. Besides, elevated fatty acids levels including butyrylcarnitine and myristic acid after infection may indicate patients at risk of suffering from dyslipidemia after LPV/r-based HAART. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. LPV H-infinity Control for the Longitudinal Dynamics of a Flexible Air-Breathing Hypersonic Vehicle

    NASA Astrophysics Data System (ADS)

    Hughes, Hunter Douglas

    This dissertation establishes the method needed to synthesize and simulate an Hinfinity Linear Parameter-Varying (LPV) controller for a flexible air-breathing hypersonic vehicle model. A study was conducted to gain the understanding of the elastic effects on the open loop system. It was determined that three modes of vibration would be suitable for the hypersonic vehicle model. It was also discovered from the open loop study that there is strong coupling in the hypersonic vehicle states, especially between the angle of attack, pitch rate, pitch attitude, and the exible modes of the vehicle. This dissertation outlines the procedure for synthesizing a full state feedback Hinfinity LPV controller for the hypersonic vehicle. The full state feedback study looked at both velocity and altitude tracking for the exible vehicle. A parametric study was conducted on each of these controllers to see the effects of changing the number of gridding points in the parameter space and changing the parameter variation rate limits in the system on the robust performance of the controller. As a result of the parametric study, a 7 x 7 grid ranging from Mach 7 to Mach 9 in velocity and from 70,000 feet to 90,000 feet in altitude, and a parameter variation rate limit of [.5 200]T was used for both the velocity tracking and altitude tracking cases. The resulting Hinfinity robust performances were gamma = 2.2224 for the velocity tracking case and = 1:7582 for the altitude tracking case. A linear analysis was then conducted on five different selected trim points from the Hinfinity LPV controller. This was conducted for the velocity tracking and altitude tracking cases. The results of linear analysis show that there is a slight difference in the response of the Hinfinity LPV controller and the fixed point H infinity controller. For the tracking task, the Hinfinity controller responds more quickly, and has a lower Hinfinity performance value. Next, the H infinity LPV controller was simulated using the nonlinear flexible hypersonic model for both the velocity tracking and altitude tracking cases. Both of these cases were subject to a ramp input and a multi-step input both with and without perturbation in the model. The results of the simulation show that the tracking state follows the command signal successfully though the perturbed system does show some higher frequency characteristics in the non-tracking states. It was discovered that there is an issue with integral windup when switching takes place in the controller, so an algorithm was implemented to reset the integration of the error on the tracking state when the switch takes place. It was also seen that there was a decline in altitude when tracking velocity, and a large change in velocity that occurred during altitude tracking. These results lead to the decision to include a unity gain regulation state on velocity for the altitude tracking and the altitude for the velocity tracking during the output feedback control synthesis. The procedure for synthesizing an output feedback H infinity LPV controller for the hypersonic vehicle is also discussed in this dissertation. The output feedback design looked at velocity tracking and altitude tracking with rigid body motion variables for both the exible and rigid body hypersonic vehicle models. As with the full state feedback controller, a parametric study was conducted on each of these controllers to determine the number of gridding points in the parameter space and the parameter variation rate limits in the system. The parametric study reveals a 7x7 grid ranging from Mach 7 to Mach 9 in velocity and from 70,000 feet to 90,000 feet in altitude, and a parameter variation rate limit of [.1 200]T is preferable for both the velocity tracking and altitude tracking cases with both the exible and rigid body assumptions. The resulting Hinfinity robust performances were gamma = 113:2146 for the exible body velocity tracking case, gamma = 83.6931 for the rigid body velocity tracking case, gamma = 107:2043 for the exible body altitude tracking case, and gamma = 97:7403 for the rigid body altitude tracking case. A linear analysis was then conducted on five different selected trim points from the Hinfinity LPV controller. The results of this analysis show that there is a larger difference in the response of the Hinfinity LPV controller and the Hinfinity controller. For the tracking task, the Hinfinity controller responds more quickly, and has a lower Hinfinity performance value. Next, the Hinfinity LPV controller was applied to the exible nonlinear plant model. The rigid body controllers were applied to the exible plant model to see if the exible nature of the vehicle could be treated as a perturbation to the system. Additionally, there were simulations run both with and without sensor noise and parametric uncertainty. The results of simulation show that the rigid body controller is able to successfully apply to the exible body model for the velocity tracking case, but is unable to stabilize the altitude tracking case. It was also seen that the system is able to track the command signal while minimizing the variations seen in the altitude for the velocity tracking case and in the velocity during the altitude tracking case. Additionally, there was no obvious effect of perturbations in the system on the tracking state or secondary regulation state. There were high frequency responses associated with the other perturbed states.

  19. State and actuator fault estimation observer design integrated in a riderless bicycle stabilization system.

    PubMed

    Brizuela Mendoza, Jorge Aurelio; Astorga Zaragoza, Carlos Manuel; Zavala Río, Arturo; Pattalochi, Leo; Canales Abarca, Francisco

    2016-03-01

    This paper deals with an observer design for Linear Parameter Varying (LPV) systems with high-order time-varying parameter dependency. The proposed design, considered as the main contribution of this paper, corresponds to an observer for the estimation of the actuator fault and the system state, considering measurement noise at the system outputs. The observer gains are computed by considering the extension of linear systems theory to polynomial LPV systems, in such a way that the observer reaches the characteristics of LPV systems. As a result, the actuator fault estimation is ready to be used in a Fault Tolerant Control scheme, where the estimated state with reduced noise should be used to generate the control law. The effectiveness of the proposed methodology has been tested using a riderless bicycle model with dependency on the translational velocity v, where the control objective corresponds to the system stabilization towards the upright position despite the variation of v along the closed-loop system trajectories. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  20. Neurocognitive impairment in patients randomized to second-line lopinavir/ritonavir-based antiretroviral therapy vs. lopinavir/ritonavir monotherapy.

    PubMed

    Bunupuradah, Torsak; Chetchotisakd, Ploenchan; Jirajariyavej, Supunnee; Valcour, Victor; Bowonwattanuwong, Chureeratana; Munsakul, Warangkana; Klinbuayaem, Virat; Prasithsirikul, Wisit; Sophonphan, Jiratchaya; Mahanontharit, Apicha; Hirschel, Bernard; Bhakeecheep, Sorakij; Ruxrungtham, Kiat; Ananworanich, Jintanat

    2012-12-01

    We compared rates of neurocognitive impairment (NCI) among 93 Thai adults failing non-nucleoside reverse transcriptase inhibitor (NNRTI)-based combination antiretroviral therapy (cART) before and after switching to lopinavir/ritonavir monotherapy (mLPV/r) vs. tenofovir/lamivudine/LPV/r (TDF/3TC/LPV/r). Participants completed the Color Trails 1 and 2, Digit Symbol, and Grooved Pegboard at weeks 0, 24, and 48. We calculated z-scores using normative data from 451 healthy HIV-negative Thais. We defined NCI as performance of <-1 SD on ≥2 tests. The Thai depression inventory was used to capture depressive symptoms. Lumbar puncture was optional at week 0 and 48. At baseline, median (IQR) age was 36.9 (32.8-40.5) years, and 46 % had primary school education or lower. The median CD4 count was 196 (107-292) cells/mm(3), and plasma HIV RNA was 4.1 (3.6-4.5) log(10) copies/ml. Almost all (97 %) had circulating recombinant CRF01_AE. At baseline, 20 (47 %) of the mLPV/r vs. 22 (44 %) of TDF/3TC/LPV/r arms met NCI criteria (p = 0.89). The frequency of NCI at week 48 was 30 vs. 32 % (p = 0.85) with 6 vs. 7 % (p = 0.85) developing NCI in the mLPV/r vs. TDF/3TC/LPV/r arms, respectively. Having NCI at baseline and lower education each predicted NCI at week 48. Depression scores at week 48 did not differ between arms (p = 0.47). Cerebrospinal fluid HIV RNA of <50 copies/ml at 48 weeks was observed in five out of seven in mLPV/r vs. three out of four in TDF/3TC/LPV/r arm. The rates of NCI and depression did not differ among cases failing NNRTI-based cART who received mLPV/r compared to LPV/r triple therapy.

  1. Output-Feedback Model Predictive Control of a Pasteurization Pilot Plant based on an LPV model

    NASA Astrophysics Data System (ADS)

    Karimi Pour, Fatemeh; Ocampo-Martinez, Carlos; Puig, Vicenç

    2017-01-01

    This paper presents a model predictive control (MPC) of a pasteurization pilot plant based on an LPV model. Since not all the states are measured, an observer is also designed, which allows implementing an output-feedback MPC scheme. However, the model of the plant is not completely observable when augmented with the disturbance models. In order to solve this problem, the following strategies are used: (i) the whole system is decoupled into two subsystems, (ii) an inner state-feedback controller is implemented into the MPC control scheme. A real-time example based on the pasteurization pilot plant is simulated as a case study for testing the behavior of the approaches.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, Tushar; Robles, Maria Teresa Sáenz; Schowalter, Rachel M.

    Polyomaviruses induce cell proliferation and transformation through different oncoproteins encoded within the early region (ER): large T antigen (LT), small T antigen (sT) and, in some cases, additional components. Each virus utilizes different mechanisms to achieve transformation. For instance, the LTs of Simian virus 40 (SV40), BK and/or JC virus can induce transformation; but Merkel Cell Polyomavirus (MCPyV) requires expression of sT. Lymphotropic Papovavirus (LPV) is closely related to Human Polyomavirus 9 (HuPyV9) and, under similar conditions, mice expressing LPV.ER exhibit higher rates of tumor formation than mice expressing SV40.ER. We have investigated the contributions of individual LPV.ER components tomore » cell transformation. In contrast to SV40, LPV.ER transforms mouse embryonic fibroblasts (MEFs), but expression of LPV LT is insufficient to transform MEFs. Furthermore, LPV sT induces immortalization and transformation of MEFs. Thus, in the case of LPV, sT is the main mediator of oncogenesis. - Highlights: • Characterization of early region products from the Lymphotropic Polyomavirus (LPV). • On its own, sT immortalizes and transforms mouse primary cells, and is able to block p53 activation. • Combined LT and sT expression induces a greater rate of proliferation than either LT or sT alone.« less

  3. Robust linear parameter-varying control of blood pressure using vasoactive drugs

    NASA Astrophysics Data System (ADS)

    Luspay, Tamas; Grigoriadis, Karolos

    2015-10-01

    Resuscitation of emergency care patients requires fast restoration of blood pressure to a target value to achieve hemodynamic stability and vital organ perfusion. A robust control design methodology is presented in this paper for regulating the blood pressure of hypotensive patients by means of the closed-loop administration of vasoactive drugs. To this end, a dynamic first-order delay model is utilised to describe the vasoactive drug response with varying parameters that represent intra-patient and inter-patient variability. The proposed framework consists of two components: first, an online model parameter estimation is carried out using a multiple-model extended Kalman-filter. Second, the estimated model parameters are used for continuously scheduling a robust linear parameter-varying (LPV) controller. The closed-loop behaviour is characterised by parameter-varying dynamic weights designed to regulate the mean arterial pressure to a target value. Experimental data of blood pressure response of anesthetised pigs to phenylephrine injection are used for validating the LPV blood pressure models. Simulation studies are provided to validate the online model estimation and the LPV blood pressure control using phenylephrine drug injection models representing patients showing sensitive, nominal and insensitive response to the drug.

  4. A linear parameter-varying multiobjective control law design based on youla parametrization for a flexible blended wing body aircraft

    NASA Astrophysics Data System (ADS)

    Demourant, F.; Ferreres, G.

    2013-12-01

    This article presents a methodology for a linear parameter-varying (LPV) multiobjective flight control law design for a blended wing body (BWB) aircraft and results. So, the method is a direct design of a parametrized control law (with respect to some measured flight parameters) through a multimodel convex design to optimize a set of specifications on the full-flight domain and different mass cases. The methodology is based on the Youla parameterization which is very useful since closed loop specifications are affine with respect to Youla parameter. The LPV multiobjective design method is detailed and applied to the BWB flexible aircraft example.

  5. Contribution of different antiretroviral regimens containing zidovudine, lamivudine and ritonavir-boosted lopinavir on HIV viral load reduction during pregnancy.

    PubMed

    Sripan, Patumrat; Le Coeur, Sophie; Ingsrisawang, Lily; Cressey, Tim R; Bouazza, Naïm; Foissac, Frantz; Ngo-Giang-Huong, Nicole; Traisathit, Patrinee; Srirompotong, Ussanee; Ayudhaya, Orada Patamasingh Na; Puangsombat, Achara; Jungpipun, Jantana; Jittayanun, Kanokwan; Tréluyer, Jean-Marc; Jourdain, Gonzague; Lallemant, Marc; Urien, Saïk

    2016-01-01

    Antiretroviral (ARV) regimens used for the prevention of mother-to-child transmission of HIV have evolved over time. We evaluated the contribution of different ARV regimens on the reduction of the plasma HIV RNA viral load (VL) during pregnancy. A total of 1,833 VL measurements from ARV-naive pregnant women participating in perinatal prevention trials in Thailand were included. Women received either zidovudine (ZDV) monotherapy, ZDV plus lopinavir/ritonavir (LPV/r), or ZDV plus lamivudine (3TC) plus LPV/r. VL time-course during pregnancy was described as a function of pretreatment VL and treatment duration using an Emax non-linear mixed-effect model. VL reduction and median time to achieve a VL<50 copies/ml were estimated for each regimen. Among 745 women, 279 (37%), 145 (20%) and 321 (43%) received ZDV monotherapy, ZDV+LPV/r and ZDV+3TC+LPV/r, respectively. The predicted VL reduction from baseline to delivery after a median of 10 weeks of treatment were 0.5, 2.7 and 2.9 log10 copies/ml with ZDV monotherapy, ZDV+LPV/r and ZDV+3TC+LPV/r, respectively. At delivery, 1%, 57% and 63% of women receiving ZDV monotherapy, ZDV+LPV/r or ZDV+3TC+LPV/r had a VL<50 copies/ml. The addition of 3TC to ZDV+LPV/r reduced the time to achieve a VL<50 copies/ml and the higher the pretreatment VL, the larger the effect 3TC had on reducing the time to VL<50 copies/ml. The addition of 3TC to ZDV+LPV/r was associated with a slight further VL reduction but the time to reach a VL<50 copies/ml was shorter. This beneficial effect of 3TC is crucial for prevention of mother-to-child transmission in women who receive ARVs late and with high pretreatment VL.

  6. Tipranavir/Ritonavir (500/200 mg and 500/100 mg) Was Virologically Non-Inferior to Lopinavir/Ritonavir (400/100 mg) at Week 48 in Treatment-Naïve HIV-1-Infected Patients: A Randomized, Multinational, Multicenter Trial.

    PubMed

    Cooper, David A; Cordery, Damien V; Zajdenverg, Roberto; Ruxrungtham, Kiat; Arastéh, Keikawus; Bergmann, Frank; Neto, José L de Andrade; Scherer, Joseph; Chaves, Ricardo L; Robinson, Patrick

    2016-01-01

    Ritonavir-boosted tipranavir (TPV/r) was evaluated as initial therapy in treatment-naïve HIV-1-infected patients because of its potency, unique resistance profile, and high genetic barrier. Trial 1182.33, an open-label, randomized trial, compared two TPV/r dose combinations versus ritonavir-boosted lopinavir (LPV/r). Eligible adults, who had no prior antiretroviral therapy were randomized to twice daily (BID) 500/100 mg TPV/r, 500/200 mg TPV/r, or 400/100 mg LPV/r. Each treatment group also received Tenofovir 300 mg + Lamivudine 300 mg QD. The primary endpoint was a confirmed viral load (VL) <50 copies/mL at week 48 without prior antiretroviral regimen changes. Primary analyses examined CD4-adjusted response rates for non-inferiority, using a 15% non-inferiority margin. At week 48, VL<50 copies/mL was 68.4%, 69.9%, and 72.4% in TPV/r100, TPV/r200, and LPV/r groups, respectively, and TPV/r groups showed non-inferiority to LPV/r. Discontinuation due to adverse events was higher in TPV/r100 (10.3%) and TPV/r200 (15.3%) recipients versus LPV/r (3.2%) recipients. The frequency of grade ≥3 transaminase elevations was higher in the TPV/r200 group than the other groups, leading to closure of this group. However, upon continued treatment or following re-introduction after treatment interruption, transaminase elevations returned to grade ≤2 in >65% of patients receiving either TPV/r200 or TPV/r100. The trial was subsequently discontinued; primary objectives were achieved and continuing TPV/r100 was less tolerable than standard of care for initial highly active antiretroviral therapy. All treatment groups had similar 48-week treatment responses. TPV/r100 and TPV/r200 regimens resulted in sustained treatment responses, which were non-inferior to LPV/r at 48 weeks. When compared with the LPV/r regimen and examined in the light of more current regimens, these TPV/r regimens do not appear to be the best options for treatment-naïve patients based on their safety profiles.

  7. Functional role of gap junctions in cytokine-induced leukocyte adhesion to endothelium in vivo

    PubMed Central

    Véliz, Loreto P.; González, Francisco G.; Duling, Brian R.; Sáez, Juan C.; Boric, Mauricio P.

    2008-01-01

    To assess the hypothesis that gap junctions (GJs) participate on leukocyte-endothelium interactions in the inflammatory response, we compared leukocyte adhesion and transmigration elicited by cytokine stimulation in the presence or absence of GJ blockers in the hamster cheek pouch and also in the cremaster muscle of wild-type (WT) and endothelium-specific connexin 43 (Cx43) null mice (Cx43e−/−). In the cheek pouch, topical tumor necrosis factor-α (TNF-α; 150 ng/ml, 15 min) caused a sustained increment in the number of leukocytes adhered to venular endothelium (LAV) and located at perivenular regions (LPV). Superfusion with the GJ blockers 18-α-glycyrrhetinic acid (AGA; 75 μM) or 18-β-glycyrrhetinic acid (50 μM) abolished the TNF-α-induced increase in LAV and LPV; carbenoxolone (75 μM) or oleamide (100 μM) reduced LAV by 50 and 75%, respectively, and LPV to a lesser extent. None of these GJ blockers modified venular diameter, blood flow, or leukocyte rolling. In contrast, glycyrrhizin (75 μM), a non-GJ blocker analog of AGA, was devoid of effect. Interestingly, when AGA was removed 90 min after TNF-α stimulation, LAV started to rise at a similar rate as in control. Conversely, application of AGA 90 min after TNF-α reduced the number of previously adhered cells. In WT mice, intrascrotal injection of TNF-α (0.5 μg/0.3 ml) increased LAV (fourfold) and LPV (threefold) compared with saline-injected controls. In contrast to the observations in WT animals, TNF-α stimulation did not increase LAV or LPV in Cx43e−/− mice. These results demonstrate an important role for GJ communication in leukocyte adhesion and transmigration during acute inflammation in vivo and further suggest that endothelial Cx43 is key in these processes. PMID:18599597

  8. Lopinavir/ritonavir, atazanavir/ritonavir, and efavirenz in antiretroviral-naïve HIV-1-infected individuals over 144 weeks: an open-label randomized controlled trial.

    PubMed

    Andersson, Lars-Magnus; Vesterbacka, Jan; Blaxhult, Anders; Flamholc, Leo; Nilsson, Staffan; Ormaasen, Vidar; Sönnerborg, Anders; Gisslén, Magnus

    2013-07-01

    The objective of this study was to compare the efficacy of ritonavir boosted atazanavir versus ritonavir boosted lopinavir or efavirenz, all in combination with 2 nucleoside analogue reverse transcriptase inhibitors (NRTIs), over 144 weeks in antiretroviral-naïve HIV-1-infected individuals. A prospective open-label randomized controlled trial was conducted at 29 sites in Sweden and Norway between April 2004 and December 2009. Patients were randomized to receive either efavirenz 600 mg once daily (EFV), or atazanavir 300 mg and ritonavir 100 mg once daily (AZV/r), or lopinavir 400 mg and ritonavir 100 mg twice daily (LPV/r). The primary endpoints were the proportion of patients with HIV-1 RNA < 50 copies/ml at 48 and 144 weeks. Of 245 patients enrolled, 243 were randomized and 239 received the allocated intervention: 77 EFV, 81 AZV/r, and 81 LPV/r. Median (interquartile range) CD4 cell counts at baseline were 150 (80-200), 170 (80-220), and 150 (90-216) per microlitre, respectively. At week 48 the proportion (95% confidence interval (CI)) of patients achieving HIV-1 RNA < 50 copies/ml was 86 (78-94)% in the EFV arm, 78 (69-87)% in the AZV/r arm and, 69 (59-78)% in the LPV/r arm in the intention-to-treat analysis. There was a significant difference between the EFV and LPV/r arm (p = 0.014). At week 144, the proportion (95% CI) of patients achieving HIV-1 RNA < 50 copies/ml was 61 (50-72)%, 58 (47-69)%, 51 (41-63)%, respectively (p = 0.8). Patients with CD4 cell counts of ≤ 200/μl or HIV-1 RNA > 100,000 copies/ml at baseline had similar response rates in all arms. EFV was superior to LPV/r at week 48, but there were no significant differences between the 3 arms in the long-term (144 weeks) follow-up.

  9. Application of intraoperative lung-protective ventilation varies in accordance with the knowledge of anaesthesiologists: a single-Centre questionnaire study and a retrospective observational study.

    PubMed

    Kim, Seung Hyun; Na, Sungwon; Lee, Woo Kyung; Choi, Hyunwoo; Kim, Jeongmin

    2018-04-02

    The benefits of lung-protective ventilation (LPV) with a low tidal volume (6 mL/kg of ideal body weight [IBW]), limited plateau pressure (< 28-30 cm H 2 O), and appropriate positive end-expiratory pressure (PEEP) in patients with acute respiratory distress syndrome have become apparent and it is now widely adopted in intensive care units. Recently evidence for LPV in general anaesthesia has been accumulated, but it is not yet generally applied by anaesthesiologists in the operating room. This study investigated the perception about intraoperative LPV among 82 anaesthesiologists through a questionnaire survey and identified the differences in ventilator settings according to recognition of lung-protective ventilation. Furthermore, we investigated the changes in the trend for using this form of ventilation during general anaesthesia in the past 10 years. Anaesthesiologists who had received training in LPV were more knowledgeable about this approach. Anaesthesiologists with knowledge of the concept behind LPV strategies applied a lower tidal volume (median (IQR [range]), 8.2 (8.0-9.2 [7.1-10.3]) vs. 9.2 (9.1-10.1 [7.6-10.1]) mL/kg; p = 0.033) and used PEEP more frequently (69/72 [95.8%] vs. 5/8 [62.5%]; p = 0.012; odds ratio, 13.8 [2.19-86.9]) for laparoscopic surgery than did those without such knowledge. Anaesthesiologists who were able to answer a question related to LPV correctly (respondents who chose 'height' to a multiple choice question asking what variables should be considered most important in the initial setting of tidal volume) applied a lower tidal volume in cases of laparoscopic surgery and obese patients. There was an increase in the number of patients receiving LPV (V T  < 10 mL/kgIBW and PEEP ≥5 cm H 2 O) between 2004 and 2014 (0/818 [0.0%] vs. 280/818 [34.2%]; p <  0.001). Our study suggests that the knowledge of LPV is directly related to its implementation, and can explain the increase in LPV use in general anaesthesia. Further studies should assess the impact of using intraoperative LPV on clinical outcomes and should determine the efficacy of education on intraoperative LPV implementation.

  10. Statistical modeling, optimization and characterization of solid self-nanoemulsifying drug delivery system of lopinavir using design of experiment.

    PubMed

    Patel, Grishma; Shelat, Pragna; Lalwani, Anita

    2016-10-01

    Lopinavir (LPV), an antiretroviral protease inhibitor shows poor bioavailability because of poor aqueous solubility and extensive hepatic first-pass metabolism. The aim of the present work was to investigate the potential of the solid self-nanoemulsifying drug delivery system (S-SNEDDS) in improving dissolution rate and oral bioavailability of LPV. Liquid SNEDDS (L-SNEDDS) of LPV were prepared using Capmul MCM C8, Cremophor RH 40 and propylene glycol and their amounts were optimized by Scheffe's mixture design. L-SNEDDS formulations were evaluated for different physicochemical and in vitro drug release parameters. S-SNEDDS were prepared by adsorbing L-SNEDDS on Neusilin US2 and characterized for solid-state properties. In vivo bioavailability of S-SNEDDS, marketed Lopinavir + Ritonavir (LPV/RTV) formulation and pure LPV was studied in Wistar rats. Stability study of S-SNEDDS was performed as per ICH guidelines. Optimized L-SNEDDS obtained by Scheffe design had drug loading 160 ± 1.15 mg, globule size 32.9 ± 1.45 nm and drug release >95% within 15 min. Solid state studies suggested the transformation of the crystalline drug to amorphous drug. The size and zeta potential of globules obtained on dilution S-SNEDDS remained similar to L-SNEEDS. In vivo bioavailability study revealed that S-SNEDDS has 2.97 and 1.54-folds higher bioavailability than pure LPV and LPV/RTV formulation, respectively. The optimized S-SNEDDS was found to be stable and had a shelf life of 2.85 years. The significant increase in drug dissolution and bioavailability by prepared SNEDDS suggest that the developed S-SNEDDS is a useful solid platform for improving oral bioavailability of poorly soluble LPV.

  11. [Challenges of lopinavir/ritonavir in the chronicity of human immunodeficiency virus infection].

    PubMed

    Aguirrebengoa, Koldo

    2014-11-01

    Combination antiretroviral therapy (ART) has increased patient survival, which is currently similar to that of the general population in western countries. However, ART is unable to completely restore normal health, given the persistence of chronic immune activation. Human immunodeficiency virus (HIV) infection has become a chronic disease and 50% of patients will soon be older than 50 years. Currently, there is a debate on the possibility of accelerated aging in the HIV-infected population. An overlap has been observed between chronic inflammation, age-related comorbidities, lifestyle, and the long-term toxicity of ART. ART-related toxicity can encourage the development of comorbidities, especially cardiovascular and renal complications, while toxicity-especially that of thymidine analogs-can also contribute to inflammation and aging. Evidence is available on simplification strategies with boosted protease inhibitor monotherapy aiming to avoid or reduce potential or demonstrated toxicity. Currently, studies are underway of dual therapy strategies with lopinavir/ritonavir (LPV/r) with distinct antiretroviral agents. The studies with the largest samples are those with raltegravir and lamivudine. The GARDEL trial has demonstrated that dual therapy with LPV/r plus a generic drug such as lamivudine is non-inferior to triple therapy in treatment- naïve patients. All of the above indicates the response to the challenge posed to LPV/r by the chronic phase of the disease and by the need to reduce costs. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  12. Origin of the Ultrafast Response of the Lateral Photovoltaic Effect in Amorphous MoS2/Si Junctions.

    PubMed

    Hu, Chang; Wang, Xianjie; Miao, Peng; Zhang, Lingli; Song, Bingqian; Liu, Weilong; Lv, Zhe; Zhang, Yu; Sui, Yu; Tang, Jinke; Yang, Yanqiang; Song, Bo; Xu, Ping

    2017-05-31

    The lateral photovoltaic (LPV) effect has attracted much attention for a long time because of its application in position-sensitive detectors (PSD). Here, we report the ultrafast response of the LPV in amorphous MoS 2 /Si (a-MoS 2 /Si) junctions prepared by the pulsed laser deposition (PLD) technique. Different orientations of the built-in field and the breakover voltages are observed for a-MoS 2 films deposited on p- and n-type Si wafers, resulting in the induction of positive and negative voltages in the a-MoS 2 /n-Si and a-MoS 2 /p-Si junctions upon laser illumination, respectively. The dependence of the LPV on the position of the illumination shows very high sensitivity (183 mV mm -1 ) and good linearity. The optical relaxation time of LPV with a positive voltage was about 5.8 μs in a-MoS 2 /n-Si junction, whereas the optical relaxation time of LPV with a negative voltage was about 2.1 μs in a-MoS 2 /p-Si junction. Our results clearly suggested that the inversion layer at the a-MoS 2 /Si interface made a good contribution to the ultrafast response of the LPV in a-MoS 2 /Si junctions. The large positional sensitivity and ultrafast relaxation of LPV may promise the a-MoS 2 /Si junction's applications in fast position-sensitive detectors.

  13. Genetic Algorithm-Guided, Adaptive Model Order Reduction of Flexible Aircrafts

    NASA Technical Reports Server (NTRS)

    Zhu, Jin; Wang, Yi; Pant, Kapil; Suh, Peter; Brenner, Martin J.

    2017-01-01

    This paper presents a methodology for automated model order reduction (MOR) of flexible aircrafts to construct linear parameter-varying (LPV) reduced order models (ROM) for aeroservoelasticity (ASE) analysis and control synthesis in broad flight parameter space. The novelty includes utilization of genetic algorithms (GAs) to automatically determine the states for reduction while minimizing the trial-and-error process and heuristics requirement to perform MOR; balanced truncation for unstable systems to achieve locally optimal realization of the full model; congruence transformation for "weak" fulfillment of state consistency across the entire flight parameter space; and ROM interpolation based on adaptive grid refinement to generate a globally functional LPV ASE ROM. The methodology is applied to the X-56A MUTT model currently being tested at NASA/AFRC for flutter suppression and gust load alleviation. Our studies indicate that X-56A ROM with less than one-seventh the number of states relative to the original model is able to accurately predict system response among all input-output channels for pitch, roll, and ASE control at various flight conditions. The GA-guided approach exceeds manual and empirical state selection in terms of efficiency and accuracy. The adaptive refinement allows selective addition of the grid points in the parameter space where flight dynamics varies dramatically to enhance interpolation accuracy without over-burdening controller synthesis and onboard memory efforts downstream. The present MOR framework can be used by control engineers for robust ASE controller synthesis and novel vehicle design.

  14. Protein Binding of Lopinavir and Ritonavir During Four Phases of Pregnancy: Implications for Treatment Guidelines

    PubMed Central

    Patterson, Kristine B.; Dumond, Julie B.; Prince, Heather A.; Jenkins, Amanda J.; Scarsi, Kimberly K.; Wang, Ruili; Malone, Stephanie; Hudgens, Michael G.; Kashuba, Angela DM.

    2013-01-01

    Objective To investigate the intraindividual pharmacokinetics of total (protein bound + unbound) and unbound lopinavir/ritonavir (LPV/RTV) and to assess whether the pediatric formulation (100mg/25mg) can overcome any pregnancy-associated changes. Design Prospective longitudinal pharmacokinetic (PK) study Methods HIV-infected pregnant antiretroviral therapy-naïve and experienced women receiving LPV/RTV 400mg/100mg tablets twice daily. Intensive PK evaluations were performed at 20–24 weeks (PK1), 30 weeks (PK2) followed by empiric dose increase using the pediatric formulation (100mg/25mg twice daily), 32 weeks (PK3), and 8 weeks postpartum (PK4). Results Twelve women completed pre-specified PK evaluations. Median (range) age was 28 (1–35) years and baseline BMI was 32 (19–41) kg/m2. During pregnancy, total area under the time concentration (AUC0–12hr) for LPV was significantly lower than postpartum [PK1, PK2 or PK3 vs. PK4, p= 0.005]. Protein unbound LPV AUC0–12hr remained unchanged during pregnancy [PK1: 1.6 (1.3–1.9) vs. PK2: 1.6 (1.3–1.9) µg*hr/mL, p=0.4] despite a 25% dose increase [PK2 vs. PK3: 1.8 (1.3–2.1) µg*hr/mL, p=0.5]. Protein unbound LPV predose concentrations (C12h) did not significantly change despite dose increase [PK2: 0.10 (0.08–0.15) vs. PK3: 0.12 (0.10–0.15) µg/mL, p=0.09]. Albumin and LPV AUC0–12h fraction unbound were correlated (rs=0.3, p=0.03). Conclusions Total LPV exposure was significantly decreased throughout pregnancy despite the increased dose. However, the exposure of unbound LPV did not change significantly regardless of trimester or dose. Predose concentrations of unbound LPV were not affected by the additional dose and were 70-fold greater than the minimum efficacy concentration. These findings suggest dose adjustments may not be necessary in all HIV-infected pregnant women. PMID:23221983

  15. Pharmacokinetics of lopinavir/ritonavir and efavirenz in food insecure HIV-infected pregnant and breastfeeding women in Tororo, Uganda

    PubMed Central

    Bartelink, Imke H.; Savic, Rada M.; Mwesigwa, Julia; Achan, Jane; Clark, Tamara; Plenty, Albert; Charlebois, Edwin; Kamya, Moses; Young, Sera L.; Gandhi, Monica; Havlir, Diane; Cohan, Deborah; Aweeka, Francesca

    2013-01-01

    Pregnancy and food insecurity may impact antiretroviral (ART) pharmacokinetics (PK), adherence and response. We sought to quantify and characterize the PK of lopinavir/ritonavir (LPV/r) and efavirenz (EFV) by pregnancy and nutritional status among HIV-infected women in Tororo, Uganda. In 2011, 62/225 ante-partum/post-partum single dried blood spot samples DBS and 43 post-partum hair samples for LPV/r were derived from 116 women, 51/194 ante-/post-partum DBS and 53 post-partum hair samples for EFV from 105 women. 80% of Ugandan participants were severely food insecure, 26% lost weight ante-partum, and median BMI post-partum was only 20.2 kg/m2. Rich PK-data of normally nourished (pregnant) women and healthy Ugandans established prior information. Overall, drug exposure was reduced (LPV −33%, EFV −15%, ritonavir −17%) compared to well-nourished controls [p < 0.001], attributable to decreased bioavailability. Pregnancy increased LPV/r clearance 68% [p < 0.001], whereas EFV clearance remained unchanged. Hair concentrations correlated with plasma-exposure [p < 0.001], explaining 29% PK-variability. In conclusion, pregnancy and food insecurity were associated with lower ART exposures in this cohort of predominantly underweight women, compared to well-nourished women. Much variability in plasma-exposure was quantified using hair concentrations. Addressing malnutrition as well as ART-PK in this setting should be a priority. PMID:24038035

  16. The Palatability of Lopinavir and Ritonavir Delivered by an Innovative Freeze-Dried Fast-Dissolving Tablet Formulation

    PubMed Central

    Brantly, Alexandra M.; Drobonick, Alexandra L.; King, Hannah T.; Mesta, Daniel C.; Richards, Caroline G.; Lal, Manjari; Lai, Manshun

    2018-01-01

    Negative hedonic sensory qualities of HIV antiretroviral drugs often reduce patient adherence particularly in pediatric populations requiring oral consumption. This study examines the palatability of an innovative delivery mechanism utilizing a freeze-drying-in-blister approach to create fast-dissolving tablets (FDTs) containing a fixed-dose combination of lopinavir and ritonavir (LPV/r). Consumption patterns of solutions during brief-access and long-term testing and baby foodstuff consumption were analyzed to evaluate the orosensory detection and avoidance of placebo FDTs containing no LPV/r (FDT−) and FDTs containing LPV/r (FDT+). Rats showed no change in consumption patterns for the placebo FDT− compared with control solutions. Rats can detect but do not avoid FDT+ at body-weight-adjusted dosages in both brief-access (30-s) and long-term (23 h) consumption tests. There is an aversive response to concentrated doses of FDT+ during brief-access tests that cannot be masked by 25% sucrose. However, the strongest FDT+ concentration was not rejected when mixed with 50 g of applesauce, banana sauce, or rice cereal baby foodstuffs. The averseness of the FDT+ was associated with the presence of LPV/r and not the FDT− formulation itself. The novel FDT formulation appears to be a palatable delivery mechanism for oral antiretroviral pharmaceuticals especially when mixed with baby foodstuffs. PMID:29593900

  17. The Palatability of Lopinavir and Ritonavir Delivered by an Innovative Freeze-Dried Fast-Dissolving Tablet Formulation.

    PubMed

    Pittman, David W; Brantly, Alexandra M; Drobonick, Alexandra L; King, Hannah T; Mesta, Daniel C; Richards, Caroline G; Lal, Manjari; Lai, Manshun

    2018-01-01

    Negative hedonic sensory qualities of HIV antiretroviral drugs often reduce patient adherence particularly in pediatric populations requiring oral consumption. This study examines the palatability of an innovative delivery mechanism utilizing a freeze-drying-in-blister approach to create fast-dissolving tablets (FDTs) containing a fixed-dose combination of lopinavir and ritonavir (LPV/r). Consumption patterns of solutions during brief-access and long-term testing and baby foodstuff consumption were analyzed to evaluate the orosensory detection and avoidance of placebo FDTs containing no LPV/r (FDT-) and FDTs containing LPV/r (FDT+). Rats showed no change in consumption patterns for the placebo FDT- compared with control solutions. Rats can detect but do not avoid FDT+ at body-weight-adjusted dosages in both brief-access (30-s) and long-term (23 h) consumption tests. There is an aversive response to concentrated doses of FDT+ during brief-access tests that cannot be masked by 25% sucrose. However, the strongest FDT+ concentration was not rejected when mixed with 50 g of applesauce, banana sauce, or rice cereal baby foodstuffs. The averseness of the FDT+ was associated with the presence of LPV/r and not the FDT- formulation itself. The novel FDT formulation appears to be a palatable delivery mechanism for oral antiretroviral pharmaceuticals especially when mixed with baby foodstuffs.

  18. Linearly polarized vector modes: enabling MIMO-free mode-division multiplexing.

    PubMed

    Wang, Lixian; Nejad, Reza Mirzaei; Corsi, Alessandro; Lin, Jiachuan; Messaddeq, Younès; Rusch, Leslie; LaRochelle, Sophie

    2017-05-15

    We experimentally investigate mode-division multiplexing in an elliptical ring core fiber (ERCF) that supports linearly polarized vector modes (LPV). Characterization show that the ERCF exhibits good polarization maintaining properties over eight LPV modes with effective index difference larger than 1 × 10 -4 . The ERCF further displays stable mode power and polarization extinction ratio when subjected to external perturbations. Crosstalk between the LPV modes, after propagating through 0.9 km ERCF, is below -14 dB. By using six LPV modes as independent data channels, we achieved the transmission of 32 Gbaud QPSK over 0.9 km ERCF without any multiple-input-multiple-output (MIMO) or polarization-division multiplexing (PDM) signal processing.

  19. Pharmacokinetics of pediatric lopinavir/ritonavir tablets in children when administered twice daily according to FDA weight bands.

    PubMed

    Bastiaans, Diane E T; Forcat, Silvia; Lyall, Hermione; Cressey, Tim R; Hansudewechakul, Rawiwan; Kanjanavanit, Suparat; Noguera-Julian, Antoni; Königs, Christoph; Inshaw, Jamie R J; Chalermpantmetagul, Suwalai; Saïdi, Yacine; Compagnucci, Alexandra; Harper, Lynda M; Giaquinto, Carlo; Colbers, Angela P H; Burger, David M

    2014-03-01

    Lopinavir/ritonavir (LPV/r) pediatric tablets (100/25 mg) are approved by the United States Food and Drug Administration (FDA) and European Medicines Agency (EMA) as part of combination antiretroviral therapy. Dosing is based on body weight bands or body surface area under FDA approval and only body surface area by the EMA. This can lead to a different recommended dose. In addition, weight band-based dosing has not been formally studied in the target population. We evaluated the pharmacokinetics (PK) of LPV/r in children, administered twice daily according to the FDA weight bands, using pediatric tablets. Fifty-three HIV-infected children were included in the PK substudy of the Paediatric European Network for the Treatment of AIDS 18 trial (KONCERT). In this study, children were randomized to receive LPV/r twice or once daily, according to FDA weight bands. A PK assessment was performed in 17, 16 and 20 children in the 15-25 kg, ≥ 25-35 kg and >35 kg weight band, respectively, while children took the tablets twice daily. Rich sampling was performed, and PK parameters were calculated by noncompartmental analysis. Given the high percentage of Asian children, it was also tested whether there was a difference in PK parameters between Asian and non-Asian children. For the total group, LPV geometric mean AUC0-12, Cmax and C12 were 106.9 h × mg/L, 12.0 mg/L and 4.9 mg/L, respectively. There were no significant differences in LPV PK parameters between the weight bands. In addition, weight was not found to be associated with variability in Cmax, C12 or AUC0-12 for the LPV PK parameters. FDA weight band-based dosing recommendations provide adequate exposure to LPV when using LPV/r pediatric tablets.

  20. Linear Parameter Varying Identification of Dynamic Joint Stiffness during Time-Varying Voluntary Contractions

    PubMed Central

    Golkar, Mahsa A.; Sobhani Tehrani, Ehsan; Kearney, Robert E.

    2017-01-01

    Dynamic joint stiffness is a dynamic, nonlinear relationship between the position of a joint and the torque acting about it, which can be used to describe the biomechanics of the joint and associated limb(s). This paper models and quantifies changes in ankle dynamic stiffness and its individual elements, intrinsic and reflex stiffness, in healthy human subjects during isometric, time-varying (TV) contractions of the ankle plantarflexor muscles. A subspace, linear parameter varying, parallel-cascade (LPV-PC) algorithm was used to identify the model from measured input position perturbations and output torque data using voluntary torque as the LPV scheduling variable (SV). Monte-Carlo simulations demonstrated that the algorithm is accurate, precise, and robust to colored measurement noise. The algorithm was then used to examine stiffness changes associated with TV isometric contractions. The SV was estimated from the Soleus EMG using a Hammerstein model of EMG-torque dynamics identified from unperturbed trials. The LPV-PC algorithm identified (i) a non-parametric LPV impulse response function (LPV IRF) for intrinsic stiffness and (ii) a LPV-Hammerstein model for reflex stiffness consisting of a LPV static nonlinearity followed by a time-invariant state-space model of reflex dynamics. The results demonstrated that: (a) intrinsic stiffness, in particular ankle elasticity, increased significantly and monotonically with activation level; (b) the gain of the reflex pathway increased from rest to around 10–20% of subject's MVC and then declined; and (c) the reflex dynamics were second order. These findings suggest that in healthy human ankle, reflex stiffness contributes most at low muscle contraction levels, whereas, intrinsic contributions monotonically increase with activation level. PMID:28579954

  1. Influence of Panax ginseng on the Steady State Pharmacokinetic Profile of Lopinavir/Ritonavir (LPV/r) in Healthy Volunteers

    PubMed Central

    Calderón, Mónica M.; Chairez, Cheryl L.; Gordon, Lori A.; Alfaro, Raul M.; Kovacs, Joseph A.; Penzak, Scott R.

    2014-01-01

    Study Objective Panax ginseng has been shown in pre-clinical studies to modulate cytochrome P450 (CYP) enzymes involved in the metabolism of HIV protease inhibitors. Therefore, the purpose of this study was to determine the influence of Panax ginseng on the pharmacokinetics of the HIV protease inhibitor combination lopinavir/ritonavir (LPV/r) in healthy volunteers. Design Single sequence, open-label, single-center pharmacokinetic investigation. Setting Government healthcare facility. Subjects Twelve healthy human volunteers. Measurements and Main Results Thirteen healthy volunteers received LPV/r (400/100 mg) twice daily for 29.5 days. On day 15 of LPV/r administration, serial blood samples were collected over 12 hrs for determination of lopinavir and ritonavir concentrations. On study day 16, subjects began taking Panax ginseng 500 mg twice daily, which they continued for 2 weeks in combination with LPV/r. On day 30 of LPV/r administration, serial blood samples were again collected over 12 hrs for determination of lopinavir and ritonavir concentrations. Lopinavir and ritonavir pharmacokinetic parameter values were determined using noncompartmental methods and compared pre- and post-ginseng administration using a student’s t-test, where P < 0.05 was accepted as statistically significant. Conclusion Neither lopinavir nor ritonavir steady-state pharmacokinetics were altered by two weeks of Panax ginseng administration to healthy human volunteers. Thus, a clinically significant interaction between Panax ginseng and LPV/r is unlikely to occur in HIV-infected patients who choose to take these agents concurrently. It is also unlikely that Panax ginseng will interact with other ritonavir-boosted protease inhibitor combinations, although confirmatory data are necessary. PMID:25142999

  2. Reproduction and mode of delivery in women with vaginismus or localised provoked vestibulodynia: a Swedish register-based study.

    PubMed

    Möller, L; Josefsson, A; Bladh, M; Lilliecreutz, C; Sydsjö, G

    2015-02-01

    To compare sociodemographics, parity and mode of delivery between women diagnosed with vaginismus or localised provoked vestibulodynia (LPV) to women without a diagnosis before first pregnancy. Retrospective, population-based register study. Sweden. All women born in Sweden 1973-83 who gave birth for the first time or remained nulliparous during the years 2001-09. Nationally linked registries were used to identify the study population. Women diagnosed with vaginismus or LPV were compared to all other women. Odds ratios for parity and mode of delivery were calculated using multinominal regression analysis and logistic regression. Parity and mode of delivery. Women with vaginismus/LPV were more likely to be unmarried (P = 0.001), unemployed (P = 0.012), have a higher educational level (P < 0.001), a lower body mass index (P < 0.001) and use nicotine during pregnancy (P = 0.008). They were less likely to give birth (adjusted odds ratio [OR] 0.61, 95% confidence interval [95% CI] 0.56-0.67). Women with vaginismus/LPV more often delivered by caesarean section (P < 0.001) especially for maternal request (adjusted OR 3.48, 95% CI 2.45-4.39). In women having vaginal delivery, those with vaginismus/LPV were more likely to suffer a perineal laceration (adjusted OR 1.87, 95% CI 1.56-2.25). Women with vaginismus/LPV are less likely to give birth and those that do are more likely to deliver by caesarean section and have a caesarean section based upon maternal request. Those women delivering vaginally are more likely to suffer perineal laceration. These findings point to the importance of not only addressing sexual function in women with vaginismus/LPV but reproductive function as well. © 2014 Royal College of Obstetricians and Gynaecologists.

  3. Long-term safety and effectiveness of lopinavir/ritonavir in antiretroviral-experienced HIV-1-infected children.

    PubMed

    Rudin, Christoph; Wolbers, Marcel; Nadal, David; Rickenbach, Martin; Bucher, Heiner C

    2010-06-01

    To evaluate the long-term safety and effectiveness of lopinavir/ritonavir (LPV/r) in a population-based cohort of HIV-1-infected children. All children enrolled in the Swiss Mother and Child HIV Cohort Study, treated with LPV/r-based combination antiretroviral treatment (cART) between November 2000 and October 2008, were included. 88 children (25 (28%) protease inhibitor (PI)-naive, 16 (18%) ART-naive) were analysed (251 patient-years on LPV/r). After 48 weeks on LPV/r, 70 children had a median (interquartile range (IQR)) decrease in HIV-1 viral load of 4.25 log (5.45-3.17; PI-naive, n=17) and 2.53 (3.68-1.38; PI-experienced, n=53). Median (IQR) increase in CD4 count was 429 (203-593; PI-naive) and 177 (21-331; PI-experienced) cells/microl. These effects remained stable throughout 192 weeks for 25 children. Treatment was stopped for viral rebound in seven and suspected toxicity in 12 children. Long-term treatment with LPV/r-based cART is safe and effective in HIV-1-infected children.

  4. [Efficacy of initial antiretroviral therapy based on lopinavir/ritonavir plus 2 nucleoside/nucleotide analogs in patients with human immunodeficiency virus type 1 infection].

    PubMed

    Zamora, Laura; Gatell, José M

    2014-11-01

    Triple combination regimens consisting of lopinavir/ritonavir (LPV/r) plus 2 nucleoside/nucleotide analogs continue to be a valid option in initial antiretroviral therapy. Other protease inhibitors boosted with ritonavir (and in future with cobicistat) have been introduced, as well as other non-nucleoside analogs (rilpivirin) and 3 integrase inhibitors. None of the new regimens have shown superiority over LPV/r or comparisons are lacking. Therefore, regimens including LPV/r continue to be recommended as initial first-line or alternative strategies in most treatment guidelines. Dual combinations with LPV/r (plus raltegravir or lamivudine) are described in another article and can provide a similar response rate to triple combinations, better tolerance, and an improved cost-efficacy ratio, both for initial therapy and in simplification strategies. In contrast, LPV/r or darunavir/r monotherapy does not seem an acceptable option in treatment-naïve patients and is becoming increasingly less acceptable in simplification strategies. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  5. Long-term effectiveness of recommended boosted protease inhibitor-based antiretroviral therapy in Europe.

    PubMed

    Santos, J R; Cozzi-Lepri, A; Phillips, A; De Wit, S; Pedersen, C; Reiss, P; Blaxhult, A; Lazzarin, A; Sluzhynska, M; Orkin, C; Duvivier, C; Bogner, J; Gargalianos-Kakolyris, P; Schmid, P; Hassoun, G; Khromova, I; Beniowski, M; Hadziosmanovic, V; Sedlacek, D; Paredes, R; Lundgren, J D

    2018-05-01

    The aim of the study was to evaluate the long-term response to antiretroviral treatment (ART) based on atazanavir/ritonavir (ATZ/r)-, darunavir/ritonavir (DRV/r)-, and lopinavir/ritonavir (LPV/r)-containing regimens. Data were analysed for 5678 EuroSIDA-enrolled patients starting a DRV/r-, ATZ/r- or LPV/r-containing regimen between 1 January 2000 and 30 June 2013. Separate analyses were performed for the following subgroups of patients: (1) ART-naïve subjects (8%) at ritonavir-boosted protease inhibitor (PI/r) initiation; (2) ART-experienced individuals (44%) initiating the new PI/r with a viral load (VL) ≤500 HIV-1 RNA copies/mL; and (3) ART-experienced patients (48%) initiating the new PI/r with a VL >500 copies/mL. Virological failure (VF) was defined as two consecutive VL measurements >200 copies/mL ≥24 weeks after PI/r initiation. Kaplan-Meier and multivariable Cox models were used to compare risks of failure by PI/r-based regimen. The main analysis was performed with intention-to-treat (ITT) ignoring treatment switches. The time to VF favoured DRV/r over ATZ/r, and both were superior to LPV/r (log-rank test; P < 0.02) in all analyses. Nevertheless, the risk of VF in ART-naïve patients was similar regardless of the PI/r initiated after controlling for potential confounders. The risk of VF in both treatment-experienced groups was lower for DRV/r than for ATZ/r, which, in turn, was lower than for LPV/r-based ART. Although confounding by indication and calendar year cannot be completely ruled out, in ART-experienced subjects the long-term effectiveness of DRV/r-containing regimens appears to be greater than that of ATZ/r and LPV/r. © 2018 British HIV Association.

  6. Impact of lopinavir-ritonavir exposure in HIV-1 infected children and adolescents in Madrid, Spain during 2000-2014.

    PubMed

    Rojas Sánchez, Patricia; Prieto, Luis; Jiménez De Ory, Santiago; Fernández Cooke, Elisa; Navarro, Maria Luisa; Ramos, José Tomas; Holguín, África

    2017-01-01

    The most-used protease-inhibitor in children is Lopinavir-ritonavir (LPV/r), which provides durable suppression of viral load and increases CD4+T-counts. This study describes the virological outcome of the HIV-1-infected paediatric population exposed to LPV/r during 15 years in Spain. Patients from the Madrid Cohort of HIV-1-infected-children and adolescents exposed to LPV/r as different line therapy during 2000-2014 were selected. The baseline epidemiological-clinical features, viral suppression, changes in CD4+T-CD8+T cell counts and drug susceptibility were recorded before and during LPV/r exposure. Drug resistance mutations (DRM) were identified in viruses from samples collected until 2011. We predicted drug susceptibility to 19 antiretrovirals among those carrying DRM using the Stanford's HIVdb Algorithm. A total of 199 (37.3%) of the 534 patients from the cohort were exposed to LPV/r during 2000-2014 in first (group 1), second (group 2) or more line-therapies (group 3). Patients were mainly Spaniards (81.9%), perinatally infected (96.5%) with subtype-B (65.3%) and HIV-diagnosed before year 2000 (67.8%). The mean age at first LPV/r exposure was 9.7 years. After protease-inhibitor exposure, viral suppression was higher in groups 1 and 2 than in group 3. Viral suppression occurred in 87.5%, 68.6% and 64.8% patients from groups 1, 2 and 3, respectively. Among the 64 patients with available resistance data during LPV/r treatment, 27(42.3%) carried DRM to protease-inhibitor, 28 (58.3%) to reverse-transcriptase-inhibitors and 21 (43.7%) to non-reverse-transcriptase-inhibitors. Darunavir/ritonavir, atazanavir-ritonavir and tipranavir/ritonavir presented the highest susceptibility and nelfinavir the lowest. A better lymphocyte recovering occurred when protease-inhibitor was taken as part of a first-line regimen and a higher number of patients reached viral suppression. The least compromised antiretrovirals for rescue antiretroviral regimens, according to DRM in the LPV/r-exposed-paediatric cohort, were mainly the new protease inhibitors.

  7. Robust control of combustion instabilities

    NASA Astrophysics Data System (ADS)

    Hong, Boe-Shong

    Several interactive dynamical subsystems, each of which has its own time-scale and physical significance, are decomposed to build a feedback-controlled combustion- fluid robust dynamics. On the fast-time scale, the phenomenon of combustion instability is corresponding to the internal feedback of two subsystems: acoustic dynamics and flame dynamics, which are parametrically dependent on the slow-time-scale mean-flow dynamics controlled for global performance by a mean-flow controller. This dissertation constructs such a control system, through modeling, analysis and synthesis, to deal with model uncertainties, environmental noises and time- varying mean-flow operation. Conservation law is decomposed as fast-time acoustic dynamics and slow-time mean-flow dynamics, served for synthesizing LPV (linear parameter varying)- L2-gain robust control law, in which a robust observer is embedded for estimating and controlling the internal status, while achieving trade- offs among robustness, performances and operation. The robust controller is formulated as two LPV-type Linear Matrix Inequalities (LMIs), whose numerical solver is developed by finite-element method. Some important issues related to physical understanding and engineering application are discussed in simulated results of the control system.

  8. Global Land Product Validation Protocols: An Initiative of the CEOS Working Group on Calibration and Validation to Evaluate Satellite-derived Essential Climate Variables

    NASA Astrophysics Data System (ADS)

    Guillevic, P. C.; Nickeson, J. E.; Roman, M. O.; camacho De Coca, F.; Wang, Z.; Schaepman-Strub, G.

    2016-12-01

    The Global Climate Observing System (GCOS) has specified the need to systematically produce and validate Essential Climate Variables (ECVs). The Committee on Earth Observation Satellites (CEOS) Working Group on Calibration and Validation (WGCV) and in particular its subgroup on Land Product Validation (LPV) is playing a key coordination role leveraging the international expertise required to address actions related to the validation of global land ECVs. The primary objective of the LPV subgroup is to set standards for validation methods and reporting in order to provide traceable and reliable uncertainty estimates for scientists and stakeholders. The Subgroup is comprised of 9 focus areas that encompass 10 land surface variables. The activities of each focus area are coordinated by two international co-leads and currently include leaf area index (LAI) and fraction of absorbed photosynthetically active radiation (FAPAR), vegetation phenology, surface albedo, fire disturbance, snow cover, land cover and land use change, soil moisture, land surface temperature (LST) and emissivity. Recent additions to the focus areas include vegetation indices and biomass. The development of best practice validation protocols is a core activity of CEOS LPV with the objective to standardize the evaluation of land surface products. LPV has identified four validation levels corresponding to increasing spatial and temporal representativeness of reference samples used to perform validation. Best practice validation protocols (1) provide the definition of variables, ancillary information and uncertainty metrics, (2) describe available data sources and methods to establish reference validation datasets with SI traceability, and (3) describe evaluation methods and reporting. An overview on validation best practice components will be presented based on the LAI and LST protocol efforts to date.

  9. A method for age-matched OCT angiography deviation mapping in the assessment of disease- related changes to the radial peripapillary capillaries.

    PubMed

    Pinhas, Alexander; Linderman, Rachel; Mo, Shelley; Krawitz, Brian D; Geyman, Lawrence S; Carroll, Joseph; Rosen, Richard B; Chui, Toco Y

    2018-01-01

    To present a method for age-matched deviation mapping in the assessment of disease-related changes to the radial peripapillary capillaries (RPCs). We reviewed 4.5x4.5mm en face peripapillary OCT-A scans of 133 healthy control eyes (133 subjects, mean 41.5 yrs, range 11-82 yrs) and 4 eyes with distinct retinal pathologies, obtained using spectral-domain optical coherence tomography angiography. Statistical analysis was performed to evaluate the impact of age on RPC perfusion densities. RPC density group mean and standard deviation maps were generated for each decade of life. Deviation maps were created for the diseased eyes based on these maps. Large peripapillary vessel (LPV; noncapillary vessel) perfusion density was also studied for impact of age. Average healthy RPC density was 42.5±1.47%. ANOVA and pairwise Tukey-Kramer tests showed that RPC density in the ≥60yr group was significantly lower compared to RPC density in all younger decades of life (p<0.01). Average healthy LPV density was 21.5±3.07%. Linear regression models indicated that LPV density decreased with age, however ANOVA and pairwise Tukey-Kramer tests did not reach statistical significance. Deviation mapping enabled us to quantitatively and visually elucidate the significance of RPC density changes in disease. It is important to consider changes that occur with aging when analyzing RPC and LPV density changes in disease. RPC density, coupled with age-matched deviation mapping techniques, represents a potentially clinically useful method in detecting changes to peripapillary perfusion in disease.

  10. An experimental investigation of clocking effects on turbine aerodynamics using a modern 3-D one and one-half stage high pressure turbine for code verification and flow model development

    NASA Astrophysics Data System (ADS)

    Haldeman, Charles Waldo, IV

    2003-10-01

    This research uses a modern 1 and 1/2 stage high-pressure (HP) turbine operating at the proper design corrected speed, pressure ratio, and gas to metal temperature ratio to generate a detailed data set containing aerodynamic, heat-transfer and aero-performance information. The data was generated using the Ohio State University Gas Turbine Laboratory Turbine Test Facility (TTF), which is a short-duration shock tunnel facility. The research program utilizes an uncooled turbine stage for which all three airfoils are heavily instrumented at multiple spans and on the HPV and LPV endwalls and HPB platform and tips. Heat-flux and pressure data are obtained using the traditional shock-tube and blowdown facility operational modes. Detailed examination show that the aerodynamic (pressure) data obtained in the blowdown mode is the same as obtained in the shock-tube mode when the corrected conditions are matched. Various experimental conditions and configurations were performed, including LPV clocking positions, off-design corrected speed conditions, pressure ratio changes, and Reynolds number changes. The main research for this dissertation is concentrated on the LPV clocking experiments, where the LPV was clocked relative to the HPV at several different passage locations and at different Reynolds numbers. Various methods were used to evaluate the effect of clocking on both the aeroperformance (efficiency) and aerodynamics (pressure loading) on the LPV, including time-resolved measurements, time-averaged measurements and stage performance measurements. A general improvement in overall efficiency of approximately 2% is demonstrated and could be observed using a variety of independent methods. Maximum efficiency is obtained when the time-average pressures are highest on the LPV, and the time-resolved data both in the time domain and frequency domain show the least amount of variation. The gain in aeroperformance is obtained by integrating over the entire airfoil as the three-dimensional effects on the LPV surface are significant.

  11. The Safety, Effectiveness and Concentrations of Adjusted Lopinavir/Ritonavir in HIV-Infected Adults on Rifampicin-Based Antitubercular Therapy

    PubMed Central

    Decloedt, Eric H.; Maartens, Gary; Smith, Peter; Merry, Concepta; Bango, Funeka; McIlleron, Helen

    2012-01-01

    Objective Rifampicin co-administration dramatically reduces plasma lopinavir concentrations. Studies in healthy volunteers and HIV-infected patients showed that doubling the dose of lopinavir/ritonavir (LPV/r) or adding additional ritonavir offsets this interaction. However, high rates of hepatotoxicity were observed in healthy volunteers. We evaluated the safety, effectiveness and pre-dose concentrations of adjusted doses of LPV/r in HIV infected adults treated with rifampicin-based tuberculosis treatment. Methods Adult patients on a LPV/r-based antiretroviral regimen and rifampicin-based tuberculosis therapy were enrolled. Doubled doses of LPV/r or an additional 300 mg of ritonavir were used to overcome the inducing effect of rifampicin. Steady-state lopinavir pre-dose concentrations were evaluated every second month. Results 18 patients were enrolled with a total of 79 patient months of observation. 11/18 patients were followed up until tuberculosis treatment completion. During tuberculosis treatment, the median (IQR) pre-dose lopinavir concentration was 6.8 (1.1–9.2) mg/L and 36/47 (77%) were above the recommended trough concentration of 1 mg/L. Treatment was generally well tolerated with no grade 3 or 4 toxicity: 8 patients developed grade 1 or 2 transaminase elevation, 1 patient defaulted additional ritonavir due to nausea and 1 patient developed diarrhea requiring dose reduction. Viral loads after tuberculosis treatment were available for 11 patients and 10 were undetectable. Conclusion Once established on treatment, adjusted doses of LPV/r co-administered with rifampicin-based tuberculosis treatment were tolerated and LPV pre-dose concentrations were adequate. PMID:22412856

  12. Sex Differences in Lopinavir (LPV) and Ritonavir (RTV) Pharmacokinetics (PKs) Among HIV-infected Females and Males

    PubMed Central

    Umeh, OC; Currier, JS; Park, JG; Cramer, Y; Hermes, AE; Fletcher, CV

    2012-01-01

    Objectives We compared the pharmacokinetics of lopinavir (LPV) and ritonavir (RTV) between female and males. Methods This two-step, multicenter, pharmacokinetic study enrolled HIV-infected adults on lopinavir/ritonavir (LPV/r) capsules (400/100mg BID) plus 1 or more NRTIs. All subjects underwent 12 hour pharmacokinetic sampling. The PK sampling was repeated in subjects receiving the LPV/r tablet formulation. Results Step 1 enrolled 37 women and 40 men; step 2 included 42 subjects from step 1 plus 35 new participants (39 women and 38 men). LPV pharmacokinetics in females and males were not significantly different with either formulation. Females had significantly higher median RTV AUC0–12h with both the soft gel capsule and tablet formulations (SGC:5395 vs. 4119 ng*hr/ml, p=0.026; tablet 5310 vs. 3941 ng*hr/ml, p=0.012), higher median Cmax (SGC:802 vs. 635 ng/mL, p=0.032; tablet: 773 vs. 570 ng/ml, p=0.006)) and lower median CL/F (SGC:18.54 vs. 24.31 L/hour, p=0.026; tablet: 18.83 vs. 25.37 L/hour, p=0.012). RTV CL/F was slower in females after weight adjustment with both formulations. Conclusion The pharmacokinetics of LPV in the SGC and tablet formulations are comparable in HIV infected subjects. Females had higher RTV AUC0–12h and lower CL/F with both formulations. The mechanism of the sex difference in RTV CL/F warrants elucidation. PMID:21233301

  13. HIV lipodystrophy in participants randomised to lopinavir/ritonavir (LPV/r) +2-3 nucleoside/nucleotide reverse transcriptase inhibitors (N(t)RTI) or LPV/r + raltegravir as second-line antiretroviral therapy.

    PubMed

    Martin, Allison; Moore, Cecilia L; Mallon, Patrick W G; Hoy, Jennifer F; Emery, Sean; Belloso, Waldo H; Phanuphak, Praphan; Ferret, Samuel; Cooper, David A; Boyd, Mark A

    2013-01-01

    To compare changes over 48 weeks in body fat, lipids, Metabolic Syndrome and cardiovascular disease risk between patients randomised 1:1 to lopinavir/ritonavir (r/LPV) plus raltegravir (RAL) compared to r/LPV plus 2-3 nucleoside/nucleotide reverse transcriptase inhibitors (N(t)RTIs) as second-line therapy. Participants were HIV-1 positive (>16 years) failing first-line treatment (2 consecutive HIV RNA >500 copies/mL) of NNRTI +2N(t)RTI. Whole body dual energy x-ray absorptiometry was performed at baseline and week 48. Data were obtained to calculate the Metabolic Syndrome and Framingham cardiovascular disease (CVD) risk score. Linear regression was used to compare mean differences between arms. Logistic regression compared incidence of metabolic syndrome. Associations between percent limb fat changes at 48 weeks with baseline variables were assessed by backward stepwise multivariate linear regression. Analyses were adjusted for gender, body mass index and smoking status. 210 participants were randomised. The mean (95% CI) increase in limb fat over 48 weeks was 15.7% (5.3, 25.9) or 0.9 kg (0.2, 1.5) in the r/LPV+N(t)RTI arm and 21.1% (11.1, 31,1) or 1.3 kg (0.7, 1.9) in the r/LPV+RAL arm, with no significant difference between treatment arms (-5.4% [-0.4 kg], p>0.1). Increases in total body fat mass (kg) and trunk fat mass (kg) were also similar between groups. Total:HDL cholesterol ratio was significantly higher in the RAL arm (mean difference -0.4 (1.4); p = 0.03), there were no other differences in lipid parameters between treatment arms. There were no statistically significant differences in CVD risk or incidence of Metabolic Syndrome between the two treatment arms. The baseline predictors of increased limb fat were high viral load, high insulin and participant's not taking lipid lowering treatment. In patients switching to second line therapy, r/LPV combined with RAL demonstrated similar improvements in limb fat as an N(t)RTI + r/LPV regimen, but a worse total:HDL cholesterol ratio over 48 weeks. This clinical trial is registered on Clinicaltrials.gov, registry number NCT00931463 http://clinicaltrials.gov/ ct2/show/NCT00931463?term = NCT00931463&rank = 1.

  14. Influence of Panax ginseng on the steady state pharmacokinetic profile of lopinavir-ritonavir in healthy volunteers.

    PubMed

    Calderón, Mónica M; Chairez, Cheryl L; Gordon, Lori A; Alfaro, Raul M; Kovacs, Joseph A; Penzak, Scott R

    2014-11-01

    Panax ginseng has been shown in preclinical studies to modulate cytochrome P450 enzymes involved in the metabolism of HIV protease inhibitors. Therefore, the purpose of this study was to determine the influence of P. ginseng on the pharmacokinetics of the HIV protease inhibitor combination lopinavir-ritonavir (LPV-r) in healthy volunteers. Single-sequence, open-label, single-center pharmacokinetic investigation. Government health care facility. Twelve healthy human volunteers. Twelve healthy volunteers received LPV-r (400-100 mg) twice/day for 29.5 days. On day 15 of LPV-r administration, serial blood samples were collected over 12 hours for determination of lopinavir and ritonavir concentrations. On study day 16, subjects began taking P. ginseng 500 mg twice/day, which they continued for 2 weeks in combination with LPV-r. On day 30 of LPV-r administration, serial blood samples were again collected over 12 hours for determination of lopinavir and ritonavir concentrations. Lopinavir and ritonavir pharmacokinetic parameter values were determined using noncompartmental methods, and preadministration and postadministration ginseng values were compared using a Student t test, where p<0.05 was accepted as statistically significant. Neither lopinavir nor ritonavir steady-state pharmacokinetics were altered by 2 weeks of P. ginseng administration to healthy human volunteers. Thus, a clinically significant interaction between P. ginseng and LPV-r is unlikely to occur in HIV-infected patients who choose to take these agents concurrently. It is also unlikely that P. ginseng will interact with other ritonavir-boosted protease inhibitor combinations, although confirmatory data are necessary. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  15. Lung-protective Ventilation in Patients with Brain Injury: A Multicenter Cross-sectional Study and Questionnaire Survey in China

    PubMed Central

    Luo, Xu-Ying; Hu, Ying-Hong; Cao, Xiang-Yuan; Kang, Yan; Liu, Li-Ping; Wang, Shou-Hong; Yu, Rong-Guo; Yu, Xiang-You; Zhang, Xia; Li, Bao-Shan; Ma, Zeng-Xiang; Weng, Yi-Bing; Zhang, Heng; Chen, De-Chang; Chen, Wei; Chen, Wen-Jin; Chen, Xiu-Mei; Du, Bin; Duan, Mei-Li; Hu, Jin; Huang, Yun-Feng; Jia, Gui-Jun; Li, Li-Hong; Liang, Yu-Min; Qin, Bing-Yu; Wang, Xian-Dong; Xiong, Jian; Yan, Li-Mei; Yang, Zheng-Ping; Dong, Chen-Ming; Wang, Dong-Xin; Zhan, Qing-Yuan; Fu, Shuang-Lin; Zhao, Lin; Huang, Qi-Bing; Xie, Ying-Guang; Huang, Xiao-Bo; Zhang, Guo-Bin; Xu, Wang-Bin; Xu, Yuan; Liu, Ya-Ling; Zhao, He-Ling; Sun, Rong-Qing; Sun, Ming; Cheng, Qing-Hong; Qu, Xin; Yang, Xiao-Feng; Xu, Ming; Shi, Zhong-Hua; Chen, Han; He, Xuan; Yang, Yan-Lin; Chen, Guang-Qiang; Sun, Xiu-Mei; Zhou, Jian-Xin

    2016-01-01

    Background: Over the years, the mechanical ventilation (MV) strategy has changed worldwide. The aim of the present study was to describe the ventilation practices, particularly lung-protective ventilation (LPV), among brain-injured patients in China. Methods: This study was a multicenter, 1-day, cross-sectional study in 47 Intensive Care Units (ICUs) across China. Mechanically ventilated patients (18 years and older) with brain injury in a participating ICU during the time of the study, including traumatic brain injury, stroke, postoperation with intracranial tumor, hypoxic-ischemic encephalopathy, intracranial infection, and idiopathic epilepsy, were enrolled. Demographic data, primary diagnoses, indications for MV, MV modes and settings, and prognoses on the 60th day were collected. Multivariable logistic analysis was used to assess factors that might affect the use of LPV. Results: A total of 104 patients were enrolled in the present study, 87 (83.7%) of whom were identified with severe brain injury based on a Glasgow Coma Scale ≤8 points. Synchronized intermittent mandatory ventilation (SIMV) was the most frequent ventilator mode, accounting for 46.2% of the entire cohort. The median tidal volume was set to 8.0 ml/kg (interquartile range [IQR], 7.0–8.9 ml/kg) of the predicted body weight; 50 (48.1%) patients received LPV. The median positive end-expiratory pressure (PEEP) was set to 5 cmH2O (IQR, 5–6 cmH2O). No PEEP values were higher than 10 cmH2O. Compared with partially mandatory ventilation, supportive and spontaneous ventilation practices were associated with LPV. There were no significant differences in mortality and MV duration between patients subjected to LPV and those were not. Conclusions: Among brain-injured patients in China, SIMV was the most frequent ventilation mode. Nearly one-half of the brain-injured patients received LPV. Patients under supportive and spontaneous ventilation were more likely to receive LPV. Trial Registration: ClinicalTrials.org NCT02517073 https://clinicaltrials.gov/ct2/show/NCT02517073. PMID:27411450

  16. Maternal and foetal outcomes among 4118 women with HIV infection treated with lopinavir/ritonavir during pregnancy: analysis of population-based surveillance data from the national study of HIV in pregnancy and childhood in the United Kingdom and Ireland.

    PubMed

    Tookey, Pat A; Thorne, Claire; van Wyk, Jean; Norton, Michael

    2016-02-04

    The National Study of HIV in Pregnancy and Childhood (NSHPC) conducts comprehensive population-based surveillance of pregnancies in women with HIV infection in the United Kingdom/Ireland. Use of antepartum antiretroviral therapy (ART) for prevention of mother-to-child transmission (MTCT) and to treat maternal infection, if required, is standard practise in this population; lopinavir/ritonavir (LPV/r) is commonly used. The study objective was to examine the use of LPV/r among pregnant women with HIV infection to describe maternal and foetal outcomes. The NSHPC study collected maternal, perinatal and paediatric data through confidential and voluntary obstetric and paediatric reporting schemes. Pregnancies reported to the NSHPC by June 2013, due to deliver 2003-2012 and with LPV/r exposure were included in this analysis, using pregnancy as the unit of observation. Four thousand eight hundred sixty-four LPV/r-exposed pregnancies resulting in 4702 deliveries in 4118 women were identified. Maternal region of birth was primarily sub-Saharan Africa (77 %) or United Kingdom/Ireland (14 %). Median maternal age at conception was 30 years. LPV/r was initiated preconception in 980 (20 %) and postconception in 3884 (80 %) pregnancies; median duration of antepartum LPV/r exposure was 270 and 107 days, respectively. Viral load close to delivery was <50 copies/mL in 73 % and <1000 copies/mL in 94 % of women. 63 % of deliveries were by caesarean section (elective, 6 %; emergency, 38 %). Among singleton live births, 13 % were <37 weeks of gestation (2.5 % <32 weeks) and 15 % had birth weight <2500 g (2.3 % <1500 g). MTCT rates were 1.1 (2003-2007) and 0.5 % (2008-2012). 134 live born children (2.9 %) had ≥1 congenital abnormality. The results of this analysis using real-world data from a large number of pregnant women with HIV infection in the United Kingdom and Ireland who received LPV/r-containing ART regimens demonstrate that these regimens have a good safety profile and are effective for viral suppression during pregnancy, with associated low rates of MTCT.

  17. PCR detection and DNA sequence analysis of the regulatory region of lymphotropic papovavirus in peripheral blood mononuclear cells of an immunocompromised rhesus macaque

    NASA Technical Reports Server (NTRS)

    Lednicky, John A.; Halvorson, Steven J.; Butel, Janet S.

    2002-01-01

    A lymphotropic papovavirus (LPV) archetypal regulatory region was amplified from DNA from the blood of an immunocompromised rhesus monkey. We believe this is the first nonserological evidence of LPV infection in rhesus monkeys.

  18. Site-specific mesenchymal control of inflammatory pain to yeast challenge in vulvodynia afflicted and pain-free women

    PubMed Central

    Foster, David C.; Falsetta, Megan L.; Woeller, Collynn F.; Pollock, Stephen J.; Song, Kunchang; Bonham, Adrienne; Haidaris, Constantine G.; Stodgell, Chris J.; Messing, Susan P.; Iadarola, Michael; Phipps, Richard P.

    2015-01-01

    Fibroblast strains were derived from two regions of the lower genital tract of localized provoked vulvodynia (LPV) cases and pain-free controls. Sixteen strains were derived from four cases and four controls, age and race matched, following pre-sampling mechanical pain threshold assessments. Strains were challenged with six separate stimuli: live yeast species (C. albicans, C. glabrata, C. tropicalis, and S. cerevisiae), yeast extract (zymosan), or inactive vehicle. Production of prostaglandin E2 (PGE2) and interleukin-6 (IL-6) were pro-inflammatory response measures. Highest IL-6 and PGE2 occurred with vestibular strains following C. albicans, C. glabrata, and zymosan challenges, resulting in the ability to significantly predict IL-6 and PGE2 production by genital tract location. Following C. albicans and C. glabrata challenge of all sixteen fibroblast strains, adjusting for dual sampling of subjects, PGE2 and IL-6 production significantly predicted the pre-sampling pain threshold from the genital tract site of sampling. At the same location of pain assessment and fibroblast sampling, in situ immunohistochemical (IHC)(+) fibroblasts for IL-6 and Cox-2 were quantified microscopically. The correlation between IL-6 production and IL-6 IHC(+) was statistically significant yet biological significance is unknown because of the small number of IHC(+) IL-6 fibroblasts identified. A low fibroblast IL-6 IHC(+) count may result from most IL-6 produced by fibroblasts existing in a secreted, extracellular state. Enhanced, site-specific, innate immune responsiveness to yeast pathogens by fibroblasts may be an early step in LPV pathogenesis. Fibroblast strain testing may offer an attractive/objective marker of LPV pathology in women with vulvodynia of inflammatory origin. PMID:25679469

  19. 76 FR 77939 - Proposed Provision of Navigation Services for the Next Generation Air Transportation System...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-15

    ... navigation for en route through non-precision instrument approaches. GPS is an internationally accepted... Localizer Performance with Vertical guidance (LPV). These approaches are equivalent to Category I ILS, but... approach procedures with LPV or localizer performance (LP) non-precision lines of minima to all qualified...

  20. Drug-resistant molecular mechanism of CRF01_AE HIV-1 protease due to V82F mutation

    NASA Astrophysics Data System (ADS)

    Liu, Xiaoqing; Xiu, Zhilong; Hao, Ce

    2009-05-01

    Human immunodeficiency virus type 1 protease (HIV-1 PR) is one of the major targets of anti-AIDS drug discovery. The circulating recombinant form 01 A/E (CRF01_AE, abbreviated AE) subtype is one of the most common HIV-1 subtypes, which is infecting more humans and is expanding rapidly throughout the world. It is, therefore, necessary to develop inhibitors against subtype AE HIV-1 PR. In this work, we have performed computer simulation of subtype AE HIV-1 PR with the drugs lopinavir (LPV) and nelfinavir (NFV), and examined the mechanism of resistance of the V82F mutation of this protease against LPV both structurally and energetically. The V82F mutation at the active site results in a conformational change of 79's loop region and displacement of LPV from its proper binding site, and these changes lead to rotation of the side-chains of residues D25 and I50'. Consequently, the conformation of the binding cavity is deformed asymmetrically and some interactions between PR and LPV are destroyed. Additionally, by comparing the interactive mechanisms of LPV and NFV with HIV-1 PR we discovered that the presence of a dodecahydroisoquinoline ring at the P1' subsite, a [2-(2,6-dimethylphenoxy)acetyl]amino group at the P2' subsite, and an N2 atom at the P2 subsite could improve the binding affinity of the drug with AE HIV-1 PR. These findings are helpful for promising drug design.

  1. Structural basis for drug and substrate specificity exhibited by FIV encoding a chimeric FIV/HIV protease

    PubMed Central

    Lin, Ying-Chuan; Perryman, Alexander L.; Olson, Arthur J.; Torbett, Bruce E.; Elder, John H.; Stout, C. David

    2011-01-01

    A chimeric feline immunodeficiency virus (FIV) protease (PR) has been engineered that supports infectivity but confers sensitivity to the human immunodeficiency virus (HIV) PR inhibitors darunavir (DRV) and lopinavir (LPV). The 6s-98S PR has five replacements mimicking homologous residues in HIV PR and a sixth which mutated from Pro to Ser during selection. Crystal structures of the 6s-98S FIV PR chimera with DRV and LPV bound have been determined at 1.7 and 1.8 Å resolution, respectively. The structures reveal the role of a flexible 90s loop and residue 98 in supporting Gag processing and infectivity and the roles of residue 37 in the active site and residues 55, 57 and 59 in the flap in conferring the ability to specifically recognize HIV PR drugs. Specifically, Ile37Val preserves tertiary structure but prevents steric clashes with DRV and LPV. Asn55Met and Val59Ile induce a distinct kink in the flap and a new hydrogen bond to DRV. Ile98Pro→Ser and Pro100Asn increase 90s loop flexibility, Gln99Val contributes hydrophobic contacts to DRV and LPV, and Pro100Asn forms compensatory hydrogen bonds. The chimeric PR exhibits a comparable number of hydrogen bonds, electrostatic interactions and hydrophobic contacts with DRV and LPV as in the corresponding HIV PR complexes, consistent with IC50 values in the nanomolar range. PMID:21636894

  2. Lopinavir Impairs Protein Synthesis and Induces eEF2 Phosphorylation via the Activation of AMP-Activated Protein Kinase

    PubMed Central

    Hong-Brown, Ly Q.; Brown, C. Randell; Huber, Danuta S.; Lang, Charles H.

    2008-01-01

    HIV anti-retroviral drugs decrease protein synthesis, although the underlying regulatory mechanisms of this process are not fully established. Therefore, we investigated the effects of the HIV protease inhibitor lopinavir (LPV) on protein metabolism. We also characterized the mechanisms that mediate the effects of this drug on elongation factor-2 (eEF2), a key component of the translational machinery. Treatment of C2C12 myocytes with LPV produced a dose-dependent inhibitory effect on protein synthesis. This effect was observed at 15 min and was maintained for at least 4 h. Mechanistically, LPV increased the phosphorylation of eEF2 and thereby decreased the activity of this protein. Increased phosphorylation of eEF2 was associated with increased activity of its upstream regulators AMP-activated protein kinase (AMPK) and eEF2 kinase (eEF2K). Both AMPK and eEF2K directly phosphorylated eEF2 in an in vitro kinase assay suggesting two distinct paths lead to eEF2 phosphorylation. To verify this connection, myocytes were treated with the AMPK inhibitor compound C. Compound C blocked eEF2K and eEF2 phosphorylation, demonstrating that LPV affects eEF2 activity via an AMPK-eEF2K dependent pathway. In contrast, incubation of myocytes with rottlerin suppressed eEF2K, but not eEF2 phosphorylation, suggesting that eEF2 can be regulated independent of eEF2K. Finally, LPV did not affect PP2A activity when either eEF2 or peptide was used as the substrate. Collectively, these results indicate that LPV decreases protein synthesis, at least in part, via inhibition of eEF2. This appears regulated by AMPK which can act directly on eEF2 or indirectly via the action of eEF2K. PMID:18712774

  3. Differential effects of efavirenz, lopinavir/r, and atazanavir/r on the initial viral decay rate in treatment naïve HIV-1-infected patients.

    PubMed

    Edén, Arvid; Andersson, Lars-Magnus; Andersson, Orjan; Flamholc, Leo; Josephson, Filip; Nilsson, Staffan; Ormaasen, Vidar; Svedhem, Veronica; Säll, Christer; Sönnerborg, Anders; Tunbäck, Petra; Gisslén, Magnus

    2010-05-01

    Initial viral decay rate may be useful when comparing the relative potency of antiretroviral regimens. Two hundred twenty-seven ART-naïve patients were randomized to receive efavirenz (EFV) (n = 74), lopinavir/ritonavir (LPV/r) (n = 77), or atazanavir/ritonavir (ATV/r) (n = 79) in combination with two NRTIs. The most frequently used NRTI combinations in the EFV and ATV/r groups were the nonthymidine analogues tenofovir and emtricitabine or lamivudine (70% and 68%, respectively) and, in the LPV/r group, lamivudine and the thymidine analogue zidovudine (89%). HIV-1 RNA was monitored during the first 28 days after treatment initiation. Phase 1 and 2 decay rate was estimated in a subset of 157 patients by RNA decrease from days 0 to 7, and days 14 to 28. One-way ANOVA and subsequent Tukey's post hoc tests were used for groupwise comparisons. Mean (95% CI) HIV-1 RNA reductions from days 0 to 28 were 2.59 (2.45-2.73), 2.42 (2.27-2.57), and 2.13 (2.01-2.25) log(10) copies/ml for the EFV-, LPV/r-, and ATV/r-based treatment groups, respectively, with a significantly larger decrease in the EFV-based group at all time points compared with ATV/r (p < 0.0001), and with LPV/r at days 7-21 (p < 0.0001-0.03). LPV/r gave a greater RNA decrease compared with ATV/r from day 14 (p = 0.02). Phase 1 decay rate was significantly higher in the EFV group compared with LPV/r (p = 0.003) or ATV/r (p < 0.0001). No difference was found in phase 2 decrease. EFV-based treatment gave a more rapid decline in HIV-1 RNA than did either of the boosted protease inhibitor-based regimens. The observed differences may reflect different inherent regimen potencies.

  4. Nevirapine- Versus Lopinavir/Ritonavir-Based Initial Therapy for HIV-1 Infection among Women in Africa: A Randomized Trial

    PubMed Central

    Lockman, Shahin; Hughes, Michael; Sawe, Fred; Zheng, Yu; McIntyre, James; Chipato, Tsungai; Asmelash, Aida; Rassool, Mohammed; Kimaiyo, Sylvester; Shaffer, Douglas; Hosseinipour, Mina; Mohapi, Lerato; Ssali, Francis; Chibowa, Margret; Amod, Farida; Halvas, Elias; Hogg, Evelyn; Alston-Smith, Beverly; Smith, Laura; Schooley, Robert; Mellors, John; Currier, Judith

    2012-01-01

    Background Nevirapine (NVP) is widely used in antiretroviral treatment (ART) of HIV-1 globally. The primary objective of the AA5208/OCTANE trial was to compare the efficacy of NVP-based versus lopinavir/ritonavir (LPV/r)-based initial ART. Methods and Findings In seven African countries (Botswana, Kenya, Malawi, South Africa, Uganda, Zambia, and Zimbabwe), 500 antiretroviral-naïve HIV-infected women with CD4<200 cells/mm3 were enrolled into a two-arm randomized trial to initiate open-label ART with tenofovir (TDF)/emtricitabine (FTC) once/day plus either NVP (n = 249) or LPV/r (n = 251) twice/day, and followed for ≥48 weeks. The primary endpoint was time from randomization to death or confirmed virologic failure ([VF]) (plasma HIV RNA<1 log10 below baseline 12 weeks after treatment initiation, or ≥400 copies/ml at or after 24 weeks), with comparison between treatments based on hazard ratios (HRs) in intention-to-treat analysis. Equivalence of randomized treatments was defined as finding the 95% CI for HR for virological failure or death in the range 0.5 to 2.0. Baseline characteristics were (median): age = 34 years, CD4 = 121 cells/mm3, HIV RNA = 5.2 log10copies/ml. Median follow-up = 118 weeks; 29 (6%) women were lost to follow-up. 42 women (37 VFs, five deaths; 17%) in the NVP and 50 (43 VFs, seven deaths; 20%) in the LPV/r arm reached the primary endpoint (HR 0.85, 95% CI 0.56–1.29). During initial assigned treatment, 14% and 16% of women receiving NVP and LPV/r experienced grade 3/4 signs/symptoms and 26% and 22% experienced grade 3/4 laboratory abnormalities. However, 35 (14%) women discontinued NVP because of adverse events, most in the first 8 weeks, versus none for LPV/r (p<0.001). VF, death, or permanent treatment discontinuation occurred in 80 (32%) of NVP and 54 (22%) of LPV/r arms (HR = 1.7, 95% CI 1.2–2.4), with the difference primarily due to more treatment discontinuation in the NVP arm. 13 (45%) of 29 women tested in the NVP versus six (15%) of 40 in the LPV/r arm had any drug resistance mutation at time of VF. Conclusions Initial ART with NVP+TDF/FTC demonstrated equivalent virologic efficacy but higher rates of treatment discontinuation and new drug resistance compared with LPV/r+TDF/FTC in antiretroviral-naïve women with CD4<200 cells/mm3. Trial registration ClinicalTrials.gov NCT00089505 Please see later in the article for the Editors' Summary PMID:22719231

  5. A Control-Theoretic Approach for the Combined Management of Quality-of-Service and Energy in Service Centers

    NASA Astrophysics Data System (ADS)

    Poussot-Vassal, Charles; Tanelli, Mara; Lovera, Marco

    The complexity of Information Technology (IT) systems is steadily increasing and system complexity has been recognised as the main obstacle to further advancements of IT. This fact has recently raised energy management issues. Control techniques have been proposed and successfully applied to design Autonomic Computing systems, trading-off system performance with energy saving goals. As users behaviour is highly time varying and workload conditions can change substantially within the same business day, the Linear Parametrically Varying (LPV) framework is particularly promising for modeling such systems. In this chapter, a control-theoretic method to investigate the trade-off between Quality of Service (QoS) requirements and energy saving objectives in the case of admission control in Web service systems is proposed, considering as control variables the server CPU frequency and the admission probability. To quantitatively evaluate the trade-off, a dynamic model of the admission control dynamics is estimated via LPV identification techniques. Based on this model, an optimisation problem within the Model Predictive Control (MPC) framework is setup, by means of which it is possible to investigate the optimal trade-off policy to manage QoS and energy saving objectives at design time and taking into explicit account the system dynamics.

  6. Wing Shaping and Gust Load Controls of Flexible Aircraft: An LPV Approach

    NASA Technical Reports Server (NTRS)

    Hammerton, Jared R.; Su, Weihua; Zhu, Guoming; Swei, Sean Shan-Min

    2018-01-01

    In the proposed paper, the optimum wing shape of a highly flexible aircraft under varying flight conditions will be controlled by a linear parameter-varying approach. The optimum shape determined under multiple objectives, including flight performance, ride quality, and control effort, will be determined as well. This work is an extension of work done previously by the authors, and updates the existing optimization and utilizes the results to generate a robust flight controller.

  7. Experimental verification of a GPC-LPV method with RLS and P1-TS fuzzy-based estimation for limiting the transient and residual vibration of a crane system

    NASA Astrophysics Data System (ADS)

    Smoczek, Jaroslaw

    2015-10-01

    The paper deals with the problem of reducing the residual vibration and limiting the transient oscillations of a flexible and underactuated system with respect to the variation of operating conditions. The comparative study of generalized predictive control (GPC) and fuzzy scheduling scheme developed based on the P1-TS fuzzy theory, local pole placement method and interval analysis of closed-loop system polynomial coefficients is addressed to the problem of flexible crane control. The two alternatives of a GPC-based method are proposed that enable to realize this technique either with or without a sensor of payload deflection. The first control technique is based on the recursive least squares (RLS) method applied to on-line estimate the parameters of a linear parameter varying (LPV) model of a crane dynamic system. The second GPC-based approach is based on a payload deflection feedback estimated using a pendulum model with the parameters interpolated using the P1-TS fuzzy system. Feasibility and applicability of the developed methods were confirmed through experimental verification performed on a laboratory scaled overhead crane.

  8. Structural basis for drug and substrate specificity exhibited by FIV encoding a chimeric FIV/HIV protease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Ying-Chuan; Perryman, Alexander L.; Olson, Arthur J.

    2011-06-01

    Crystal structures of the 6s-98S FIV protease chimera with darunavir and lopinavir bound have been determined at 1.7 and 1.8 Å resolution, respectively. A chimeric feline immunodeficiency virus (FIV) protease (PR) has been engineered that supports infectivity but confers sensitivity to the human immunodeficiency virus (HIV) PR inhibitors darunavir (DRV) and lopinavir (LPV). The 6s-98S PR has five replacements mimicking homologous residues in HIV PR and a sixth which mutated from Pro to Ser during selection. Crystal structures of the 6s-98S FIV PR chimera with DRV and LPV bound have been determined at 1.7 and 1.8 Å resolution, respectively. Themore » structures reveal the role of a flexible 90s loop and residue 98 in supporting Gag processing and infectivity and the roles of residue 37 in the active site and residues 55, 57 and 59 in the flap in conferring the ability to specifically recognize HIV PR drugs. Specifically, Ile37Val preserves tertiary structure but prevents steric clashes with DRV and LPV. Asn55Met and Val59Ile induce a distinct kink in the flap and a new hydrogen bond to DRV. Ile98Pro→Ser and Pro100Asn increase 90s loop flexibility, Gln99Val contributes hydrophobic contacts to DRV and LPV, and Pro100Asn forms compensatory hydrogen bonds. The chimeric PR exhibits a comparable number of hydrogen bonds, electrostatic interactions and hydrophobic contacts with DRV and LPV as in the corresponding HIV PR complexes, consistent with IC{sub 50} values in the nanomolar range.« less

  9. Functional cohesion of gene sets determined by latent semantic indexing of PubMed abstracts.

    PubMed

    Xu, Lijing; Furlotte, Nicholas; Lin, Yunyue; Heinrich, Kevin; Berry, Michael W; George, Ebenezer O; Homayouni, Ramin

    2011-04-14

    High-throughput genomic technologies enable researchers to identify genes that are co-regulated with respect to specific experimental conditions. Numerous statistical approaches have been developed to identify differentially expressed genes. Because each approach can produce distinct gene sets, it is difficult for biologists to determine which statistical approach yields biologically relevant gene sets and is appropriate for their study. To address this issue, we implemented Latent Semantic Indexing (LSI) to determine the functional coherence of gene sets. An LSI model was built using over 1 million Medline abstracts for over 20,000 mouse and human genes annotated in Entrez Gene. The gene-to-gene LSI-derived similarities were used to calculate a literature cohesion p-value (LPv) for a given gene set using a Fisher's exact test. We tested this method against genes in more than 6,000 functional pathways annotated in Gene Ontology (GO) and found that approximately 75% of gene sets in GO biological process category and 90% of the gene sets in GO molecular function and cellular component categories were functionally cohesive (LPv<0.05). These results indicate that the LPv methodology is both robust and accurate. Application of this method to previously published microarray datasets demonstrated that LPv can be helpful in selecting the appropriate feature extraction methods. To enable real-time calculation of LPv for mouse or human gene sets, we developed a web tool called Gene-set Cohesion Analysis Tool (GCAT). GCAT can complement other gene set enrichment approaches by determining the overall functional cohesion of data sets, taking into account both explicit and implicit gene interactions reported in the biomedical literature. GCAT is freely available at http://binf1.memphis.edu/gcat.

  10. Cost/efficacy analysis of preferred Spanish AIDS study group regimens and the dual therapy with lopinavir/ritonavir plus lamivudine for initial ART in HIV infected adults.

    PubMed

    Gatell Artigas, Josep María; Arribas López, José Ramón; Lázaro Y de Mercado, Pablo; Blasco Bravo, Antonio Javier

    2016-01-01

    The National AIDS Plan and the Spanish AIDS study group (GESIDA) proposes "preferred regimens" (PR) of antiretroviral treatment (ART) as initial therapy in HIV-infected patients. In 2013, the recommended regimens were all triple therapy regimens. The Gardel Study assessed the efficacy of a dual therapy (DT) combination of lopinavir/ritonavir (LPV/r) plus lamivudine (3TC). Our objective is to evaluate the GESIDA PR and the DT regimen LPV/r+3TC cost/efficacy ratios. Decision tree models were built. probability of having viral load <50 copies/mL at week 48. ART regime cost: costs of ART, adverse effects, and drug resistance tests during the first 48 weeks. Cost/efficacy ratios varied between 5,817 and 13,930 euros per responder at 48 weeks, for the DT of LPV/r+3TC and tenofovir DF/emtricitabine+raltegravir, respectively. Taking into account the official Spanish prices of ART, the most efficient regimen was DT of LPV/r+3TC, followed by the triple therapy with non-nucleoside containing regimens. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  11. Optimisation of antiretroviral therapy in HIV-infected children under 3 years of age.

    PubMed

    Penazzato, Martina; Prendergast, Andrew J; Muhe, Lulu M; Tindyebwa, Denis; Abrams, Elaine

    2014-05-22

    In the absence of antiretroviral therapy (ART), over 50% of HIV-infected infants progress to AIDS and death by 2 years of age. However, there are challenges to initiation of ART in early life, including the possibility of drug resistance in the context of prevention of mother-to-child transmission (PMTCT) programs, a paucity of drug choices , uncertain dosing for some medications and long-term toxicities. Key management decisions include when to start ART, what regimen to start, and whether and when to substitute drugs or interrupt therapy. This review, an update of a previous review, aims to summarize the currently available evidence on this topic and inform the ART management in HIV-infected children less than 3 years of age. To evaluate 1) when to start ART in young children (less than 3 years); 2) what ART to start with, comparing first-line non-nucleoside reverse transcriptase inhibitor (NNRTI) and protease inhibitor (PI)-based regimens; and 3) whether alternative strategies should be used to optimize antiretroviral treatment in this population: induction (initiation with 4 drugs rather than 3 drugs) followed by maintenance ART, interruption of ART and substitution of PI with NNRTI drugs once virological suppression is achieved on a PI-based regimen. Search methodsWe searched for published studies in the Cochrane HIV/AIDS Review Group Trials Register, The Cochrane Library, Pubmed, EMBASE and CENTRAL. We screened abstracts from relevant conference proceedings and searched for unpublished and ongoing trials in clinical trial registries (ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform). We identified RCTs that recruited perinatally HIV-infected children under 3 years of age without restriction of setting. We rejected trials that did not include children less than 3 years of age, did not provide stratified outcomes for those less than 3 years or did not evaluate either timing of ART initiation, choice of drug regimen or treatment switch/interruption strategy. Two reviewers independently applied study selection criteria, assessed study quality and extracted data. Effects were assessed using the hazard ratio (HR) for time-to-event outcomes, relative risk for dichotomous outcomes and weighted mean difference for continuous outcomes. A search of the databases identified a total of 735 unique, previously unreviewed studies, of which 731 were excluded to leave 4 new studies to incorporate into the review. Four additional studies were identified in conference proceedings, for a total of 8 studies addressing when to start treatment (n=2), what to start (n=3), whether to substitute lopinavir/ritonavir (LPV/r) with nevirapine (NVP) (n=1), whether to use an induction-maintenance ART strategy (n=1) and whether to interrupt treatment (n=1).Treatment initiation in asymptomatic infants with good immunological status was associated with a 75% reduction (HR=0.25; 95%CI 0.12-0.51; p=0.0002) in mortality or disease progression in the one trial with sufficient power to address this question. In a smaller pilot trial, median CD4 cell count was not significantly different between early and deferred treatment groups 12 months after ART.Regardless of previous exposure to nevirapine for PMTCT, the hazard for treatment failure at 24 weeks was 1.79 (95%CI 1.33, 2.41) times higher in children starting ART with a NVP-based regimen compared to those starting with a LPV/r-based regimen (p=0.0001) with no clear difference in the effect observed for children younger or older than 1 year. The hazard for virological failure at 24 weeks was overall 1.84 (95%CI 1.29, 2.63) times higher for children starting ART with a NVP-based regimen compared to those starting with a LPV/r-based regimen (p=0.0008) with a larger difference in time to virological failure (or death) between the NVP and LPV/r-based regimens when ART was initiated in the first year of life.Infants starting a LPV/r regimen and achieving sustained virological suppression who then substituted LPV/r with NVP after median 9 months on LPV/r were less likely to develop virological failure (defined as at least one VL greater than 50 copies/mL) compared with infants who started and stayed on LPV/r (HR=0.62, 95%CI 0.41, 0.92, p=0.02). However the hazard for confirmed failure at a higher viral load (>1000 copies/mL) was greater among children who switched to NVP compared to those who remained on LPV/r (HR=10.19, 95% CI 2.36, 43.94, p=0.002).Children undergoing an induction-maintenance ART approach with a 4-drug NNRTI-based regimen for 36 weeks, followed by 3-drug ART, had significantly greater CD4 rise than children receiving a standard 3-drug NNRTI-based ART at 36 weeks (mean difference 1.70 [95%CI 0.61, 2.79] p=0.002) and significantly better viral load response at 24 weeks (OR 1.99 [95%CI 1.09, 3.62] p=0.02). However, the immunological and virological benefits were short-term.The one trial of treatment interruption that compared children initiating continuous ART from infancy with children interrupting ART was terminated early because the duration of treatment interruption was less than 3 months in most infants. Children interrupting treatment had similar growth and occurrence of serious adverse events as those in the continuous arm. ART initiation in asymptomatic children under 1 year of age reduces morbidity and mortality, but it remains unclear whether there are clinical benefits to starting ART in asymptomatic children diagnosed with HIV infection between 1-3 years.The available evidence shows that a LPV/r-based first-line regimen is more efficacious than a NVP-based regimen, regardless of PMTCT exposure status. New formulations of LPV/r are urgently required to enable new WHO recommendations to be implemented. An alternative approach to long-term LPV/r is substituting LPV/r with NVP once virological suppression is achieved. This strategy looked promising in the one trial undertaken, but may be difficult to implement in the absence of routine viral load testing.A 4-drug induction-maintenance approach showed short-term virological and immunological benefits during the induction phase but, in the absence of sustained benefits, is not recommended as a routine treatment strategy. Treatment interruption following early ART initiation in infancy was challenging for children who were severely immunocompromised in the context of poor clinical immunological condition at ART initiation due to the short duration of interruption, and is therefore not practical in ART treatment programmes where close monitoring is not feasible.

  12. Using electric pulse and laser to trigger a sharp and nonvolatile change of lateral photovoltage in nano-carbon film

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gan, Zhikai; Zhou, Peiqi; Huang, Xu

    A greatly enhanced lateral photovoltage (LPV) triggered by electric pulse has been observed in nano-carbon oxide semiconductor (COS) structures. The original maximal output signal of lateral photovoltage achieved in these structures is 9.8 mV. However, by combining the application of a 60 V voltage pulse with laser illumination, the LPV can reach a very high value of 183 mV and the change ratio after 60 V pulse is nearly 1800%. In addition, the states of these light and electric-pulse triggered COSs are permanently changed, showing a non-volatile characteristic. We attribute this phenomenon to the trapping effect of stimulated electrons in COSs. The work suggestsmore » an approach for tailoring LPV-based devices by electric pulse and will be useful for the development of electric pulse modulated photodetectors.« less

  13. Lopinavir/ritonavir induces the hepatic activity of cytochrome P450 enzymes CYP2C9, CYP2C19, and CYP1A2 but inhibits the hepatic and intestinal activity of CYP3A as measured by a phenotyping drug cocktail in healthy volunteers.

    PubMed

    Yeh, Rosa F; Gaver, Vincent E; Patterson, Kristine B; Rezk, Naser L; Baxter-Meheux, Faustina; Blake, Michael J; Eron, Joseph J; Klein, Cheri E; Rublein, John C; Kashuba, Angela D M

    2006-05-01

    The effect of lopinavir/ritonavir (LPV/r) administration on cytochrome P450 (CYP) enzyme activity was quantified using a phenotyping biomarker cocktail. Changes in CYP2C9, CYP2C19, CYP3A, CYP1A2, N-acetyltransferase-2 (NAT-2), and xanthine oxidase (XO) activities were evaluated using warfarin (WARF) + vitamin K, omeprazole (OMP), intravenous (IV) and oral (PO) midazolam (MDZ), and caffeine (CAF). : Open-label, multiple-dose, pharmacokinetic study in healthy volunteers. Subjects (n = 14) simultaneously received PO WARF 10 mg, vitamin K 10 mg, OMP 40 mg, CAF 2 mg/kg, and IV MDZ 0.025 mg/kg on days (D) 1 and 14, and PO MDZ 5 mg on D2 and D15. LPV/r (400/100 mg twice daily) was administered on D4-17. CYP2C9 and CYP2C19 activities were quantified by S-WARF AUC0-inf and OMP/5-hydroxy OMP ratio, respectively. CYP1A2, NAT-2, and XO activities were quantified by urinary CAF metabolite ratios. Hepatic and intestinal + hepatic CYP3A activities were quantified by IV (CL) and PO (CL/F) MDZ clearance, respectively. After LPV/r therapy, CYP2C9, CYP2C19, and CYP1A2 activity increased by 29%, 100%, and 43% (P = 0.001, 0.046, and 0.001), respectively. No changes were seen in NAT-2 or XO activity. Hepatic and intestinal + hepatic CYP3A activity decreased by 77% (P < 0.001) and 92% (P = 0.001), respectively. LPV/r therapy results in modest induction of CYP1A2 and CYP2C9 and potent induction of CYP2C19 activity. Increasing doses of concomitant medications metabolized by these enzymes may be necessary. LPV/r inhibited intestinal CYP3A to a greater extent than hepatic CYP3A activity. Doses of concomitant CYP3A substrates should be reduced when combined with LPV/r, although intravenously administered compounds may require less of a relative dose reduction than orally administered compounds.

  14. [Immunogenicity of sabin inactivated poliovirus vaccine induced by diphtheria-tetanus-acellular pertussis and Sabin inactivated poliovirus combined vaccine].

    PubMed

    Ma, Yan; Qin, Min; Hu, Hui-Qiong; Ji, Guang; Feng, Ling; Gao, Na; Gu, Jie; Xie, Bing-Feng; He, Ji-Hong; Sun, Ming-Bo

    2011-06-01

    In order to search the preparation process and optimazing dosage ratio of adsorbed diphtheria-tetanus-acellular pertussis and sabin inactivated poliovirus combined vaccine (DTaP-sIPV), the neutralizing antibody titers of IPV induced by different concentration of DTaP-sIPV were investigated on rats. Two batches of DTaP-sLPV were produced using different concentration of sIPV and the quality control was carried. Together with sabin-IPV and DTaP-wIPV ( boostrix-polio, GSK, Belgium) as control group, the DTaP-sIPV were administrated on three-dose schedule at 0, 1, 2 month on rats. Serum sample were collected 30 days after each dose and neutralizing antibody titers against three types poliovirus were determined using micro-neutralization test. Two batches of prepared DTaP-sIPV and control sLPV were according to the requirement of Chinese Pharmacopoeia (Volume III, 2005 edition) and showed good stability. The seropositivity rates were 100% for sabin inactivated poliovirus antigen in all groups. The GMTs (Geometric mean titers) of neutralizing antibodies against three types poliovirus increased. The prepared DTaP-sIPV was safe, stable and effective and could induced high level neutralizing antibody against poliovirus on rats.

  15. Left Atrial Anatomy in Patients Undergoing Ablation for Atrial Fibrillation.

    PubMed

    Krum, David; Hare, John; Gilbert, Carol; Choudhuri, Indrajit; Mori, Naoyo; Sra, Jasbir

    2013-01-01

    Background: Left atrial anatomy is highly variable, asymmetric, irregular and three-dimensionally unique. This variability can affect the outcome of atrial ablation. A catalog of anatomic varieties may aid patient selection and ablation approach and provide better tools for left atrial ablation. Methods: We analyzed computed tomography scans from 514 patients undergoing left atrial ablation. Images were processed on Advantage Windows with CardEP™ software (GE Healthcare, Waukesha, WI). Measurements of pulmonary vein (PV) ostial size along the long and short axes were made using double oblique cuts, and area of the ostia was calculated. Results: Patients with 2 left (LPV) and 2 right PVs (RPV) (62.6%), 2 LPVs and 3 RPVs (17.3%) and 1 LPV and 2 RPVs (14.2%) made up the three most common variants. In the 2-LPV/2-RPV anatomy, the ostial size and area of the RPVs were larger than their corresponding LPVs (p<0.001), and the ostial size and area of the superior PVs were larger than their corresponding inferior PVs (p<0.001). In the 2-LPV/3-RPV anatomy, the total area of the RPVs was larger than the total area of the LPVs (p<0.001). In the 1-LPV/2-RPV anatomy, the ostial size of the left common PV was larger than either right PV (p<0.007). However, the total area of the RPVs was larger than the area of the left common PV (p<0.002). The left common PV was also larger than any of the left veins in any of the other anatomies. The total PV area between the three most common anatomies was not significantly different. Conclusions: More than 37% of patients have a left atrial anatomy other than 2 left and 2 right PVs. This data may help in designing approaches for left atrial ablation, tailoring the procedure to individual patients and improving ablation tools.

  16. Role of progenitor cell producing normal vagina by metaplasia in laparoscopic peritoneal vaginoplasty

    PubMed Central

    Mhatre, Pravin N.; Narkhede, Hemraj R.; Pawar, P. Amol; Mhatre, P. Jyoti; Kumar, Das Dhanjit

    2016-01-01

    CONTEXT: Host of vaginoplasty techniques have been described. None has been successful in developing normal vagina. Laparoscopic peritoneal vaginoplasty (LPV) is performed in Mayer–Rokitansky–Küster–Hauser syndrome (MRKHS) culminating in normal vagina. AIMS: This study aims to confirm normal development of neovagina by anatomical and functional parameters of histology, cytology, and ultrasonography (USG) in LPV. To identify peritoneal progenitor cell by OCT4/SOX2 markers. To demonstrate the metaplastic conversion of peritoneum to neovagina and the progenitor cell concentration, distribution pattern. SETTINGS AND DESIGN: This is prospective experimental study, conducted at teaching hospital and private hospital. SUBJECTS AND METHODS: Fifteen women of MRKHS underwent LPV followed by histology, cytology, two-/three-dimensional USG of neovagina. Four women underwent peritoneal biopsy for identification of progenitor cells with OCT4/SOX2 markers. One patient underwent serial biopsies for 4 weeks for histology and progenitor cell immunohistochemistry. RESULTS: Normal vaginal histology and cytology were apparent. USG of neovagina showed normal appearance and blood flow. Two peritoneal samples confirmed the presence of progenitor cells. Serial biopsies demonstrated the epithelial change from single to multilayer with stromal compaction and neoangiogenesis. The progenitor cells concentration and different distribution patterns were described using SOX2/OCT4 markers. CONCLUSIONS: We have shown successful peritoneal metaplastic conversion to normal vagina in LPV. The progenitor cell was identified in normal peritoneum using SOX2/OCT4 markers. The progenitor cell concentration and pattern were demonstrated at various stages of neovaginal development. PMID:28216908

  17. Hypothermic total liquid ventilation after experimental aspiration-associated acute respiratory distress syndrome.

    PubMed

    Rambaud, Jérôme; Lidouren, Fanny; Sage, Michaël; Kohlhauer, Matthias; Nadeau, Mathieu; Fortin-Pellerin, Étienne; Micheau, Philippe; Zilberstein, Luca; Mongardon, Nicolas; Ricard, Jean-Damien; Terada, Megumi; Bruneval, Patrick; Berdeaux, Alain; Ghaleh, Bijan; Walti, Hervé; Tissier, Renaud

    2018-05-02

    Ultrafast cooling by total liquid ventilation (TLV) provides potent cardio- and neuroprotection after experimental cardiac arrest. However, this was evaluated in animals with no initial lung injury, whereas out-of-hospital cardiac arrest is frequently associated with early-onset pneumonia, which may lead to acute respiratory distress syndrome (ARDS). Here, our objective was to determine whether hypothermic TLV could be safe or even beneficial in an aspiration-associated ARDS animal model. ARDS was induced in anesthetized rabbits through a two-hits model including the intra-tracheal administration of a pH = 1 solution mimicking gastric content and subsequent gaseous non-protective ventilation during 90 min (tidal volume [Vt] = 10 ml/kg with positive end-expiration pressure [PEEP] = 0 cmH 2 O). After this initial period, animals either received lung protective gas ventilation (LPV; Vt = 8 ml/kg and PEEP = 5 cmH 2 O) under normothermic conditions, or hypothermic TLV (TLV; Vt = 8 ml/kg and end-expiratory volume = 15 ml/kg). Both strategies were applied for 120 min with a continuous monitoring of respiratory and cardiovascular parameters. Animals were then euthanized for pulmonary histological analyses. Eight rabbits were included in each group. Before randomization, all animals elicited ARDS with arterial oxygen partial pressure over inhaled oxygen fraction ratios (PaO 2 /FiO 2 ) below 100 mmHg, as well as decreased lung compliance. After randomization, body temperature rapidly decreased in TLV versus LPV group (32.6 ± 0.6 vs. 38.2 ± 0.4 °C after 15 min). Static lung compliance and gas exchanges were not significantly different in the TLV versus LPV group (PaO 2 /FiO 2  = 62 ± 4 vs. 52 ± 8 mmHg at the end of the procedure, respectively). Mean arterial pressure and arterial bicarbonates levels were significantly higher in TLV versus LPV. Histological analysis also showed significantly lower inflammation in TLV versus LPV group (median histological score = 3 vs. 4.5/5, respectively; p = 0.03). Hypothermic TLV can be safely induced in rabbits during aspiration-associated ARDS. It modified neither gas exchanges nor respiratory mechanics but reduced lung inflammation and hemodynamic failure in comparison with LPV. Since hypothermic TLV was previously shown to provide neuro- and cardio protective effects after cardiac arrest, these findings suggest a possible use of TLV in the settings of cardiac arrest-associated ARDS.

  18. Cost-effectiveness analysis of lopinavir/ritonavir and atazanavir+ritonavir regimens in the CASTLE study.

    PubMed

    Simpson, Kit N; Rajagopalan, Rukmini; Dietz, Birgitta

    2009-02-01

    The purpose of the study was to conduct a cost-effectiveness analysis and budget impact analysis comparing lopinavir with ritonavir (LPV/r) and atazanavir plus ritonavir (ATV+RTV) for antiretroviral-naïve patients with a baseline CD4+ T-cell distribution and total cholesterol (TC) profile as reported in the CASTLE study. This decision analysis study used a previously published Markov model of HIV disease, incorporating coronary heart disease (CHD) events to compare the short- and long-term budget impacts and CHD consequences expected for the two regimens. Patients were assumed to have a baseline CHD risk of 4.6% (based on demographic data) and it was also assumed that 50% of the population in the CASTLE study were smokers. The CHD risk differences (based on percent of patients with TC >240 mg/dL) in favor of ATV+RTV resulted in an average improvement in life expectancy of 0.031 quality-adjusted life years (QALYs) (11 days), and an incremental cost-effectiveness ratio of $1,409,734/QALY. Use of the LPV/r regimen saved $24,518 and $36,651 at 5 and 10 years, respectively, with lifetime cost savings estimated at $38,490. A sensitivity analysis using a cohort of all smokers on antihypertensive medication estimated an average improvement in life expectancy of 31 quality-adjusted days in favor of ATV+RTV, and a cost-effectiveness ratio of $520,861/QALY: a ratio that is still above the acceptable limit within the US. The use of an LPV/r-based regimen in antiretroviral-naïve patients with a baseline CHD risk similar to patients in the CASTLE study appears to be a more cost-effective use of resources compared with an ATV+RTV-based regimen. The very small added CHD risk predicted by LPV/r treatment is more than offset by the substantial short- and long-term cost savings expected with the use of LPV/r in antiretroviral-naïve individuals with average to moderately elevated CHD risk.

  19. The relation between treatment outcome and efavirenz, atazanavir or lopinavir exposure in the NORTHIV trial of treatment-naïve HIV-1 infected patients.

    PubMed

    Josephson, Filip; Andersson, Maria C H; Flamholc, Leo; Gisslén, Magnus; Hagberg, Lars; Ormaasen, Vidar; Sönnerborg, Anders; Vesterbacka, Jan; Böttiger, Ylva

    2010-04-01

    The relation between treatment outcome and trough plasma concentrations of efavirenz (EFV), atazanavir (ATV) and lopinavir (LPV) was studied in a pharmacokinetic/pharmacodynamic substudy of the NORTHIV trial-a randomised phase IV efficacy trial comparing antiretroviral-naïve human immunodeficiency virus-1-infected patients treated with (1) EFV + 2 nucleoside reverse transcriptase inhibitors (2NRTI) once daily, (2) ritonavir-boosted ATV + 2NRTI once daily or (3) ritonavir-boosted LPV + 2NRTI twice daily. The findings were related to the generally cited minimum effective concentration levels for the respective drugs (EFV 1,000 ng/ml, ATV 150 ng/ml, LPV 1,000 ng/ml). The relation between atazanavir-induced hyperbilirubinemia and virological efficacy was also studied. Drug concentrations were sampled at weeks 4 and 48 and optionally at week 12 and analysed by high-performance liquid chromatography with UV detector. When necessary, trough values were imputed by assuming the reported average half-lives for the respective drugs. Outcomes up to week 48 are reported. No relation between plasma concentrations of EFV, ATV or LPV and virological failure, treatment withdrawal due to adverse effects or antiviral potency (viral load decline from baseline to week 4) was demonstrated. Very few samples were below the suggested minimum efficacy cut-offs, and their predictive value for treatment failure could not be validated. There was a trend toward an increased risk of virological failure in patients on ATV who had an average increase of serum bilirubin from baseline of <25 micromol/l. The great majority of treatment-naïve and adherent patients on standard doses of EFV, ritonavir-boosted ATV and ritonavir-boosted LPV have drug concentrations above that considered to deliver the maximum effect for the respective drug. The results do not support the use of routine therapeutic drug monitoring (TDM) for efficacy optimisation in treatment-naïve patients on these drugs, although TDM may still be of value in some cases of altered pharmacokinetics, adverse events or drug interactions. Serum bilirubin may be a useful marker of adherence to ATV therapy.

  20. Sensor fault diagnosis of singular delayed LPV systems with inexact parameters: an uncertain system approach

    NASA Astrophysics Data System (ADS)

    Hassanabadi, Amir Hossein; Shafiee, Masoud; Puig, Vicenc

    2018-01-01

    In this paper, sensor fault diagnosis of a singular delayed linear parameter varying (LPV) system is considered. In the considered system, the model matrices are dependent on some parameters which are real-time measurable. The case of inexact parameter measurements is considered which is close to real situations. Fault diagnosis in this system is achieved via fault estimation. For this purpose, an augmented system is created by including sensor faults as additional system states. Then, an unknown input observer (UIO) is designed which estimates both the system states and the faults in the presence of measurement noise, disturbances and uncertainty induced by inexact measured parameters. Error dynamics and the original system constitute an uncertain system due to inconsistencies between real and measured values of the parameters. Then, the robust estimation of the system states and the faults are achieved with H∞ performance and formulated with a set of linear matrix inequalities (LMIs). The designed UIO is also applicable for fault diagnosis of singular delayed LPV systems with unmeasurable scheduling variables. The efficiency of the proposed approach is illustrated with an example.

  1. Long-acting combination anti-HIV drug suspension enhances and sustains higher drug levels in lymph node cells than in blood cells and plasma.

    PubMed

    Kraft, John C; McConnachie, Lisa A; Koehn, Josefin; Kinman, Loren; Collins, Carol; Shen, Danny D; Collier, Ann C; Ho, Rodney J Y

    2017-03-27

    The aim of the present study was to determine whether a combination of anti-HIV drugs - tenofovir (TFV), lopinavir (LPV) and ritonavir (RTV) - in a lipid-stabilized nanosuspension (called TLC-ART101) could enhance and sustain intracellular drug levels and exposures in lymph node and blood cells above those in plasma. Four macaques were given a single dose of TLC-ART101 subcutaneously. Drug concentrations in plasma and mononuclear cells of the blood (PBMCs) and lymph nodes (LNMCs) were analysed using a validated combination LC-MS/MS assay. For the two active drugs (TFV, LPV), plasma and PBMC intracellular drug levels persisted for over 2 weeks; PBMC drug exposures were three- to four-fold higher than those in plasma. Apparent terminal half-lives (t1/2) of TFV and LPV were 65.3 and 476.9 h in plasma, and 169.1 and 151.2 h in PBMCs. At 24 and 192 h, TFV and LPV drug levels in LNMCs were up to 79-fold higher than those in PBMCs. Analysis of PBMC intracellular TFV and its active metabolite TFV-diphosphate (TFV-DP) indicated that intracellular exposures of total TFV and TFV-DP were markedly higher and persisted longer than in humans and macaques dosed with oral TFV prodrugs, tenofovir disoproxil fumarate (TDF) or tenofovir alafenamide (TAF). A simple, scalable three-drug combination, lipid-stabilized nanosuspension exhibited persistent drug levels in cells of lymph nodes and the blood (HIV host cells) and in plasma. With appropriate dose adjustment, TLC-ART101 may be a useful HIV treatment with a potential to impact residual virus in lymph nodes.

  2. Dyslipidemias and Elevated Cardiovascular Risk on Lopinavir-Based Antiretroviral Therapy in Cambodia

    PubMed Central

    Ly, Sowath; Ouk, Vara; Chanroeurn, Hak; Thavary, Saem; Boroath, Ban; Canestri, Ana; Viretto, Gérald; Delfraissy, Jean-François; Ségéral, Olivier

    2016-01-01

    Background Lopinavir/ritonavir (LPV/r) is widely used in Cambodia with high efficacy but scarce data exist on long-term metabolic toxicity. Methods We carried out a cross-sectional and retrospective study evaluating metabolic disorders and cardiovascular risk in Cambodian patients on LPV/r-based antiretroviral therapy (ART) for > 1 year followed in Calmette Hospital, Phnom Penh. Data collected included cardiovascular risk factors, fasting blood lipids and glucose, and retrospective collection of bioclinical data. We estimated the 10-year risks of coronary heart disease with the Framingham, Ramathibodi-Electricity Generating Authority of Thailand (Rama-EGAT), and the Data Collection on Adverse Effects of Anti-HIV Drugs (D:A:D) risk equations. We identified patients with LDL above targets defined by the French expert group on HIV and by the HIV Medicine Association of the Infectious Disease Society of America and the Adult AIDS Clinical Trials Group (IDSA-AACTG). Results Of 115 patients enrolled—mean age 40.9 years, 69.2% male, mean time on LPV/r 3.8 years—40 (34.8%) had hypercholesterolemia (> 2.40 g/L), and 69 (60.0%) had low HDL cholesterol (< 0.40 g/L). Twelve (10.5%), 28 (24%) and 9 (7.7%) patients had a 10-year risk of coronary heart disease ≥ 10% according to the Framingham, D:A:D, and Rama-EGAT score, respectively. Fifty one (44.4%) and 36 (31.3%) patients had not reached their LDL target according to IDSA-AACTG and French recommendations, respectively. Conclusion Prevalence of dyslipidemia was high in this cohort of HIV-infected Cambodian patients on LPV/r. Roughly one third had high LDL levels requiring specific intervention. PMID:27579612

  3. The effect of malnutrition on the pharmacokinetics and virologic outcomes of lopinavir, efavirenz and nevirapine in food insecure HIV-infected children in Tororo, Uganda.

    PubMed

    Bartelink, Imke H; Savic, Rada M; Dorsey, Grant; Ruel, Theodore; Gingrich, David; Scherpbier, Henriette J; Capparelli, Edmund; Jullien, Vincent; Young, Sera L; Achan, Jane; Plenty, Albert; Charlebois, Edwin; Kamya, Moses; Havlir, Diane; Aweeka, Francesca

    2015-03-01

    Malnutrition may impact the pharmacokinetics (PKs) of antiretroviral medications and virologic responses in HIV-infected children. The authors therefore evaluated the PK of nevirapine (NVP), efavirenz (EFV) and lopinavir (LPV) in associations with nutritional status in a cohort of HIV-infected Ugandan children. Sparse dried blood spot samples from Ugandan children were used to estimate plasma concentrations. Historical PK data from children from 3 resource-rich countries (RRC) were utilized to develop the PK models. Concentrations in 330 dried blood spot from 163 Ugandan children aged 0.7-7 years were analyzed in reference to plasma PK data (1189 samples) from 204 children from RRC aged 0.5-12 years. Among Ugandan children, 48% was malnourished (underweight, thin or stunted). Compared to RRC, Ugandan children exhibited reduced bioavailability of EFV and LPV; 11% (P=0.045) and 18% (P=0.008), respectively. In contrast, NVP bioavailability was 46% higher in Ugandan children (P<0.001) with a trend toward greater bioavailability when malnourished. Children receiving LPV, EFV or NVP had comparable risk of virologic failure. Among children on NVP, low height and weight for age Z scores were associated with reduced risk of virologic failure (P=0.034, P=0.068, respectively). Ugandan children demonstrated lower EFV and LPV and higher NVP exposure compared to children in RRC, perhaps reflecting the consequence of malnutrition on bioavailability. In children receiving NVP, the relation between exposure, malnutrition and outcome turned out to be marginally significant. Further investigations are warranted using more intensive PK measurements and adequate adherence assessments, to further assess causes of virologic failure in Ugandan children.

  4. Model Order Reduction of Aeroservoelastic Model of Flexible Aircraft

    NASA Technical Reports Server (NTRS)

    Wang, Yi; Song, Hongjun; Pant, Kapil; Brenner, Martin J.; Suh, Peter

    2016-01-01

    This paper presents a holistic model order reduction (MOR) methodology and framework that integrates key technological elements of sequential model reduction, consistent model representation, and model interpolation for constructing high-quality linear parameter-varying (LPV) aeroservoelastic (ASE) reduced order models (ROMs) of flexible aircraft. The sequential MOR encapsulates a suite of reduction techniques, such as truncation and residualization, modal reduction, and balanced realization and truncation to achieve optimal ROMs at grid points across the flight envelope. The consistence in state representation among local ROMs is obtained by the novel method of common subspace reprojection. Model interpolation is then exploited to stitch ROMs at grid points to build a global LPV ASE ROM feasible to arbitrary flight condition. The MOR method is applied to the X-56A MUTT vehicle with flexible wing being tested at NASA/AFRC for flutter suppression and gust load alleviation. Our studies demonstrated that relative to the fullorder model, our X-56A ROM can accurately and reliably capture vehicles dynamics at various flight conditions in the target frequency regime while the number of states in ROM can be reduced by 10X (from 180 to 19), and hence, holds great promise for robust ASE controller synthesis and novel vehicle design.

  5. Intelligent, Robust Control of Deteriorated Turbofan Engines via Linear Parameter Varying Quadratic Lyapunov Function Design

    NASA Technical Reports Server (NTRS)

    Turso, James A.; Litt, Jonathan S.

    2004-01-01

    A method for accommodating engine deterioration via a scheduled Linear Parameter Varying Quadratic Lyapunov Function (LPVQLF)-Based controller is presented. The LPVQLF design methodology provides a means for developing unconditionally stable, robust control of Linear Parameter Varying (LPV) systems. The controller is scheduled on the Engine Deterioration Index, a function of estimated parameters that relate to engine health, and is computed using a multilayer feedforward neural network. Acceptable thrust response and tight control of exhaust gas temperature (EGT) is accomplished by adjusting the performance weights on these parameters for different levels of engine degradation. Nonlinear simulations demonstrate that the controller achieves specified performance objectives while being robust to engine deterioration as well as engine-to-engine variations.

  6. Humoral and cellular immune responses to Yersinia pestis Pla antigen in humans immunized with live plague vaccine.

    PubMed

    Feodorova, Valentina A; Lyapina, Anna M; Khizhnyakova, Maria A; Zaitsev, Sergey S; Sayapina, Lidiya V; Arseneva, Tatiana E; Trukhachev, Alexey L; Lebedeva, Svetlana A; Telepnev, Maxim V; Ulianova, Onega V; Lyapina, Elena P; Ulyanov, Sergey S; Motin, Vladimir L

    2018-06-01

    To establish correlates of human immunity to the live plague vaccine (LPV), we analyzed parameters of cellular and antibody response to the plasminogen activator Pla of Y. pestis. This outer membrane protease is an essential virulence factor that is steadily expressed by Y. pestis. PBMCs and sera were obtained from a cohort of naïve (n = 17) and LPV-vaccinated (n = 34) donors. Anti-Pla antibodies of different classes and IgG subclasses were determined by ELISA and immunoblotting. The analysis of antibody response was complicated with a strong reactivity of Pla with normal human sera. The linear Pla B-cell epitopes were mapped using a library of 15-mer overlapping peptides. Twelve peptides that reacted specifically with sera of vaccinated donors were found together with a major cross-reacting peptide IPNISPDSFTVAAST located at the N-terminus. PBMCs were stimulated with recombinant Pla followed by proliferative analysis and cytokine profiling. The T-cell recall response was pronounced in vaccinees less than a year post-immunization, and became Th17-polarized over time after many rounds of vaccination. The Pla protein can serve as a biomarker of successful vaccination with LPV. The diagnostic use of Pla will require elimination of cross-reactive parts of the antigen.

  7. Brief Report: Lopinavir Hair Concentrations Are the Strongest Predictor of Viremia in HIV-Infected Asian Children and Adolescents on Second-Line Antiretroviral Therapy.

    PubMed

    Pintye, Jillian; Bacchetti, Peter; Teeraananchai, Sirinya; Kerr, Stephen; Prasitsuebsai, Wasana; Singtoroj, Thida; Kuncze, Karen; Louie, Alexander; Koss, Catherine A; Jin, Chengshi; Phung, Nhi; Horng, Howard; Sohn, Annette H; Gandhi, Monica

    2017-12-01

    Children/adolescents display suboptimal antiretroviral therapy (ART) adherence and outcomes versus adults. Hair ART concentrations are objective adherence measures that predict viremia in adults but longitudinal data on hair levels in pediatric populations is limited. We assessed the predictive utility of hair lopinavir (LPV) levels on viremia among youth on second-line ART. We examined predictors of viremia (HIV-1 RNA >400 and >1000 copies/mL) at least 24 weeks after switch to LPV-based second-line ART in a cohort of HIV-infected Asian children followed between 2011 and 2014. Small hair samples, HIV-1 RNA, and self-reported adherence were collected biannually. Hair concentrations of LPV were measured through liquid chromatography/tandem mass spectrometry using validated methods. Time-to-first viremia was examined using discrete-time Cox models. Overall, 244 children met the inclusion criteria for the present analysis. Approximately half (55%) were boys and the median age 10 years [interquartile range (IQR) 7-13]; 40% were older than 11 years. At switch to second-line ART, median CD4 count was 300 (IQR 146-547) cells/mm and median HIV-RNA level was 5.0 (IQR 4.3-5.6) log10/mL. Median time of study follow-up was 48 weeks and a median of 3 (range 1-5) hair samples were collected from each participant. Adjusting for age, sex, country, self-reported adherence, CD4, and HIV-RNA, higher LPV hair concentrations were the strongest predictor of lower odds of viremia (HIV-RNA >400 copies/mL adjusted odds ratio = 0.41 per doubling in hair concentration, 95% confidence interval: 0.29 to 0.58, P < 0.001; HIV-RNA >1000 copies/mL, adjusted odds ratio = 0.54, 95% confidence interval: 0.45 to 0.65, P < 0.001). Hair concentrations predict viremia among children with HIV on second-line ART and could guide clinical decisions for this population.

  8. MRAC Control with Prior Model Knowledge for Asymmetric Damaged Aircraft

    PubMed Central

    Zhang, Jing

    2015-01-01

    This paper develops a novel state-tracking multivariable model reference adaptive control (MRAC) technique utilizing prior knowledge of plant models to recover control performance of an asymmetric structural damaged aircraft. A modification of linear model representation is given. With prior knowledge on structural damage, a polytope linear parameter varying (LPV) model is derived to cover all concerned damage conditions. An MRAC method is developed for the polytope model, of which the stability and asymptotic error convergence are theoretically proved. The proposed technique reduces the number of parameters to be adapted and thus decreases computational cost and requires less input information. The method is validated by simulations on NASA generic transport model (GTM) with damage. PMID:26180839

  9. Post-Stall Aerodynamic Modeling and Gain-Scheduled Control Design

    NASA Technical Reports Server (NTRS)

    Wu, Fen; Gopalarathnam, Ashok; Kim, Sungwan

    2005-01-01

    A multidisciplinary research e.ort that combines aerodynamic modeling and gain-scheduled control design for aircraft flight at post-stall conditions is described. The aerodynamic modeling uses a decambering approach for rapid prediction of post-stall aerodynamic characteristics of multiple-wing con.gurations using known section data. The approach is successful in bringing to light multiple solutions at post-stall angles of attack right during the iteration process. The predictions agree fairly well with experimental results from wind tunnel tests. The control research was focused on actuator saturation and .ight transition between low and high angles of attack regions for near- and post-stall aircraft using advanced LPV control techniques. The new control approaches maintain adequate control capability to handle high angle of attack aircraft control with stability and performance guarantee.

  10. Renal tubular disease in the era of combination antiretroviral therapy.

    PubMed

    Hamzah, Lisa; Booth, John W; Jose, Sophie; McAdoo, Stephen P; Kumar, Emil A; O'Donnell, Patrick; Hilton, Rachel; Sabin, Caroline; Williams, Deborah I; Jones, Rachael; Post, Frank A

    2015-09-10

    To describe the spectrum of renal tubular disease (RTD) in HIV-positive patients and its association with exposure to antiretroviral therapy (ART). Review of 265 consecutive renal biopsies from HIV-positive patients attending eight clinics in the United Kingdom between 2000 and 2012. We described the clinical characteristics of patients with RTD and compared current/recent exposure (at the time of, or up to 3 months prior to the date of biopsy) to potentially nephrotoxic ART [tenofovir (TDF), atazanavir (ATV), indinavir (IDV) and lopinavir/ritonavir (LPV/r)]. We also analysed the incidence of RTD in the UK CHIC cohort. Kruskall-Wallis, analysis of variance and Fisher's exact tests were used to evaluate between-group differences. Of the 60 RTD cases, 54 (90%) were included in the analyses. RTD comprised of three distinct patterns: acute tubular injury (ATI, n = 22), tubulo-interstitial nephritis (TIN, n = 20) and interstitial fibrosis and tubular atrophy (IFTA, n = 12). Compared with TIN and IFTA, ATI cases were less likely to be of black ethnicity (10 vs. 42-55%; P = 0.006), more likely to be on ART (100 vs. 55-68%; P = 0.001), with HIV-RNA below 200 copies/ml (100 vs. 54-58%; P < 0.001), and more likely to have current/recent exposure to TDF (P < 0.001). We did not find evidence for an association between exposure to TDF, ATV/r or LPV/r and either TIN or IFTA. RTD was present in approximately 20% of renal biopsies and comprised three distinct injury patterns with considerable clinical overlap. ATI was associated with TDF exposure, although the overall incidence of biopsy-defined ATI was low.

  11. [Lack of bioavailability of generic lopinavir/ritonavir not prequalified by WHO marketed in Africa (Congo Brazzaville)].

    PubMed

    Camara, S; Zucman, D; Vasse, M; Goudjo, A; Guillard, E; Peytavin, G

    2015-02-01

    Although second-line generic antiretroviral drugs are of great value in developing countries there are concerns regarding their quality and safety. This study is a case report and pharmacological study in healthy volunteers. A French subject of sub-saharan origin who visited Republic of Congo received a post-exposure treatment with AZT+3TC and LPV/r (200/50 mg, Arga-L®, India) following unprotected sexual intercourse. Two days later, in France, tests showed that plasma concentrations of lopinavir and ritonavir were undetectable. The WHO prequalification list showed Arga-L® was not prequalified. A pharmacological study in healthy volunteers evaluated oral bioavailability: plasma concentrations of generic LPV/r Arga-L® and LPV/r Kaletra® (400/100 mg) were measured after one single dose at 7 days apart in four healthy volunteers. Concentrations of Arga-L® at 12 h after intake were considerably lower than those of Kaletra®, revealing very low oral bioavailability of generic lopinavir and ritonavir (<10%) compared to the brand-name drug. We found that Arga-L®, despite having adequate qualitative and quantitative drug contents, had very poor bio availability compared to Kaletra®. In order to avoid the selection and the spread of drug-resistant HIV strains, rigorous pharmacological monitoring of generic antiretroviral drugs that are not pre-qualified by WHO, but are marketed in Africa, must be a priority for health authorities.

  12. Motion control of planar parallel robot using the fuzzy descriptor system approach.

    PubMed

    Vermeiren, Laurent; Dequidt, Antoine; Afroun, Mohamed; Guerra, Thierry-Marie

    2012-09-01

    This work presents the control of a two-degree of freedom parallel robot manipulator. A quasi-LPV approach, through the so-called TS fuzzy model and LMI constraints problems is used. Moreover, in this context a way to derive interesting control laws is to keep the descriptor form of the mechanical system. Therefore, new LMI problems have to be defined that helps to reduce the conservatism of the usual results. Some relaxations are also proposed to leave the pure quadratic stability/stabilization framework. A comparison study between the classical control strategies from robotics and the control design using TS fuzzy descriptor models is carried out to show the interest of the proposed approach. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.

  13. Costs and cost-effectiveness analysis of 2015 GESIDA/Spanish AIDS National Plan recommended guidelines for initial antiretroviral therapy in HIV-infected adults.

    PubMed

    Berenguer, Juan; Rivero, Antonio; Blasco, Antonio Javier; Arribas, José Ramón; Boix, Vicente; Clotet, Bonaventura; Domingo, Pere; González-García, Juan; Knobel, Hernando; Lázaro, Pablo; López, Juan Carlos; Llibre, Josep M; Lozano, Fernando; Miró, José M; Podzamczer, Daniel; Tuset, Montserrat; Gatell, Josep M

    2016-01-01

    GESIDA and the AIDS National Plan panel of experts suggest a preferred (PR), alternative (AR) and other regimens (OR) for antiretroviral treatment (ART) as initial therapy in HIV-infected patients for 2015. The objective of this study is to evaluate the costs and the effectiveness of initiating treatment with these regimens. Economic assessment of costs and effectiveness (cost/effectiveness) based on decision tree analyses. Effectiveness was defined as the probability of reporting a viral load <50 copies/mL at week 48, in an intention-to-treat analysis. Cost of initiating treatment with an ART regimen was defined as the costs of ART and its consequences (adverse effects, changes of ART regimen, and drug resistance studies) during the first 48 weeks. The payer perspective (National Health System) was applied, only taking into account differential direct costs: ART (official prices), management of adverse effects, studies of resistance, and HLA B*5701 testing. The setting is Spain and the costs correspond to those of 2015. A deterministic sensitivity analysis was conducted, building three scenarios for each regimen: base case, most favourable and least favourable. In the base case scenario, the cost of initiating treatment ranges from 4663 Euros for 3TC+LPV/r (OR) to 10,902 Euros for TDF/FTC+RAL (PR). The effectiveness varies from 0.66 for ABC/3TC+ATV/r (AR) and ABC/3TC+LPV/r (OR), to 0.89 for TDF/FTC+DTG (PR) and TDF/FTC/EVG/COBI (AR). The efficiency, in terms of cost/effectiveness, ranges from 5280 to 12,836 Euros per responder at 48 weeks, for 3TC+LPV/r (OR) and RAL+DRV/r (OR), respectively. The most efficient regimen was 3TC+LPV/r (OR). Among the PR and AR, the most efficient regimen was TDF/FTC/RPV (AR). Among the PR regimes, the most efficient was ABC/3TC+DTG. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  14. Selection of drug-resistant feline immunodeficiency virus (FIV) encoding FIV/HIV chimeric protease in the presence of HIV-specific protease inhibitors.

    PubMed

    Lin, Ying-Chuan; Happer, Meaghan; Elder, John H

    2013-08-01

    An infectious chimeric feline immunodeficiency virus (FIV)/HIV strain carrying six HIV-like protease (PR) mutations (I37V/N55M/V59I/I98S/Q99V/P100N) was subjected to selection in culture against the PR inhibitor lopinavir (LPV), darunavir (DRV), or TL-3. LPV selection resulted in the sequential emergence of V99A (strain S-1X), I59V (strain S-2X), and I108V (strain S-3X) mutations, followed by V37I (strain S-4X). Mutant PRs were analyzed in vitro, and an isogenic virus producing each mutant PR was analyzed in culture for LPV sensitivity, yielding results consistent with the original selection. The 50% inhibitory concentrations (IC50s) for S-1X, S-2X, S-3X, and S-4X were 95, 643, 627, and 1,543 nM, respectively. The primary resistance mutations, V99(82)A, I59(50)V, and V37(32)I, are consistent with the resistance pattern developed by HIV-1 under similar selection conditions. While resistance to LPV emerged readily, similar PR mutations causing resistance to either DRV or TL-3 failed to emerge after passage for more than a year. However, a G37D mutation in the nucleocapsid (NC) was observed in both selections and an isogenic G37D mutant replicated in the presence of 100 nM DRV or TL-3, whereas parental chimeric FIV could not. An additional mutation, L92V, near the PR active site in the folded structure recently emerged during TL-3 selection. The L92V mutant PR exhibited an IC50 of 50 nM, compared to 35 nM for 6s-98S PR, and processed the NC-p2 junction more efficiently, consistent with increased viral fitness. These findings emphasize the role of mutations outside the active site of PR in increasing viral resistance to active-site inhibitors and suggest additional targets for inhibitor development.

  15. Selection of Drug-Resistant Feline Immunodeficiency Virus (FIV) Encoding FIV/HIV Chimeric Protease in the Presence of HIV-Specific Protease Inhibitors

    PubMed Central

    Lin, Ying-Chuan; Happer, Meaghan

    2013-01-01

    An infectious chimeric feline immunodeficiency virus (FIV)/HIV strain carrying six HIV-like protease (PR) mutations (I37V/N55M/V59I/I98S/Q99V/P100N) was subjected to selection in culture against the PR inhibitor lopinavir (LPV), darunavir (DRV), or TL-3. LPV selection resulted in the sequential emergence of V99A (strain S-1X), I59V (strain S-2X), and I108V (strain S-3X) mutations, followed by V37I (strain S-4X). Mutant PRs were analyzed in vitro, and an isogenic virus producing each mutant PR was analyzed in culture for LPV sensitivity, yielding results consistent with the original selection. The 50% inhibitory concentrations (IC50s) for S-1X, S-2X, S-3X, and S-4X were 95, 643, 627, and 1,543 nM, respectively. The primary resistance mutations, V9982A, I5950V, and V3732I, are consistent with the resistance pattern developed by HIV-1 under similar selection conditions. While resistance to LPV emerged readily, similar PR mutations causing resistance to either DRV or TL-3 failed to emerge after passage for more than a year. However, a G37D mutation in the nucleocapsid (NC) was observed in both selections and an isogenic G37D mutant replicated in the presence of 100 nM DRV or TL-3, whereas parental chimeric FIV could not. An additional mutation, L92V, near the PR active site in the folded structure recently emerged during TL-3 selection. The L92V mutant PR exhibited an IC50 of 50 nM, compared to 35 nM for 6s-98S PR, and processed the NC-p2 junction more efficiently, consistent with increased viral fitness. These findings emphasize the role of mutations outside the active site of PR in increasing viral resistance to active-site inhibitors and suggest additional targets for inhibitor development. PMID:23720716

  16. Costs and cost-efficacy analysis of the 2016 GESIDA/Spanish AIDS National Plan recommended guidelines for initial antiretroviral therapy in HIV-infected adults.

    PubMed

    Rivero, Antonio; Pérez-Molina, José Antonio; Blasco, Antonio Javier; Arribas, José Ramón; Crespo, Manuel; Domingo, Pere; Estrada, Vicente; Iribarren, José Antonio; Knobel, Hernando; Lázaro, Pablo; López-Aldeguer, José; Lozano, Fernando; Moreno, Santiago; Palacios, Rosario; Pineda, Juan Antonio; Pulido, Federico; Rubio, Rafael; de la Torre, Javier; Tuset, Montserrat; Gatell, Josep M

    2017-02-01

    GESIDA and the AIDS National Plan panel of experts suggest preferred (PR), alternative (AR), and other regimens (OR) for antiretroviral treatment (ART) as initial therapy in HIV-infected patients for the year 2016. The objective of this study is to evaluate the costs and the efficacy of initiating treatment with these regimens. Economic assessment of costs and efficiency (cost/efficacy) based on decision tree analyses. Efficacy was defined as the probability of reporting a viral load <50copies/mL at week 48 in an intention-to-treat analysis. Cost of initiating treatment with an ART regimen was defined as the costs of ART and its consequences (adverse effects, changes of ART regimen, and drug resistance studies) during the first 48 weeks. The payer perspective (National Health System) was applied, only taking into account differential direct costs: ART (official prices), management of adverse effects, studies of resistance, and HLA B*5701 testing. The setting is Spain and the costs correspond to those of 2016. A sensitivity deterministic analysis was conducted, building three scenarios for each regimen: base case, most favourable, and least favourable. In the base case scenario, the cost of initiating treatment ranges from 4663 Euros for 3TC+LPV/r (OR) to 10,894 Euros for TDF/FTC+RAL (PR). The efficacy varies from 0.66 for ABC/3TC+ATV/r (AR) and ABC/3TC+LPV/r (OR), to 0.89 for TDF/FTC+DTG (PR) and TDF/FTC/EVG/COBI (AR). The efficiency, in terms of cost/efficacy, ranges from 5280 to 12,836 Euros per responder at 48 weeks, for 3TC+LPV/r (OR), and RAL+DRV/r (OR), respectively. Despite the overall most efficient regimen being 3TC+LPV/r (OR), among the PR and AR, the most efficient regimen was ABC/3TC/DTG (PR). Among the AR regimes, the most efficient was TDF/FTC/RPV. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  17. Intensification of antiretroviral therapy through addition of enfuvirtide in naive HIV-1-infected patients with severe immunosuppression does not improve immunological response: results of a randomized multicenter trial (ANRS 130 Apollo).

    PubMed

    Joly, Véronique; Fagard, Catherine; Grondin, Carine; Descamps, Diane; Yazdanpanah, Yazdan; Charpentier, Charlotte; Colin de Verdiere, Nathalie; Tabuteau, Sophie; Raffi, François; Cabie, André; Chene, Geneviève; Yeni, Patrick

    2013-02-01

    We studied whether addition of enfuvirtide (ENF) to a background combination antiretroviral therapy (cART) would improve the CD4 cell count response at week 24 in naive patients with advanced HIV disease. ANRS 130 Apollo is a randomized study, conducted in naive HIV-1-infected patients, either asymptomatic with CD4 counts of <100/mm(3) or stage B/C disease with CD4 counts of <200/mm(3). Patients received tenofovir-emtricitabine with lopinavir-ritonavir (LPV/r) or efavirenz and were randomized to receive ENF for 24 weeks (ENF arm) or not (control arm). The primary endpoint was the proportion of patients with CD4 counts of ≥ 200/mm(3) at week 24. A total of 195 patients were randomized: 73% had stage C disease, 78% were male, the mean age was 44 years, the median CD4 count was 30/mm(3), and the median HIV-1 RNA load was 5.4 log(10) copies/ml. Eighty-one percent of patients received LPV/r. One patient was lost to follow-up, and eight discontinued the study (four in each arm). The proportions of patients with CD4 counts of ≥ 200/mm(3) at week 24 were 34% and 38% in the ENF and control arms, respectively (P = 0.53). The proportions of patients with HIV-1 RNA loads of <50 copies/ml were 74% and 58% at week 24 in the ENF and control arms, respectively (P < 0.02), and the proportion reached 79% in both arms at week 48. Twenty (20%) and 12 patients (13%) in the ENF and control arms, respectively, experienced at least one AIDS event during follow-up (P = 0.17). Although inducing a more rapid virological response, addition of ENF to a standard cART does not improve the immunological outcome in naive HIV-infected patients with severe immunosuppression.

  18. Intensification of Antiretroviral Therapy through Addition of Enfuvirtide in Naive HIV-1-Infected Patients with Severe Immunosuppression Does Not Improve Immunological Response: Results of a Randomized Multicenter Trial (ANRS 130 Apollo)

    PubMed Central

    Fagard, Catherine; Grondin, Carine; Descamps, Diane; Yazdanpanah, Yazdan; Charpentier, Charlotte; Colin de Verdiere, Nathalie; Tabuteau, Sophie; Raffi, François; Cabie, André; Chene, Geneviève; Yeni, Patrick

    2013-01-01

    We studied whether addition of enfuvirtide (ENF) to a background combination antiretroviral therapy (cART) would improve the CD4 cell count response at week 24 in naive patients with advanced HIV disease. ANRS 130 Apollo is a randomized study, conducted in naive HIV-1-infected patients, either asymptomatic with CD4 counts of <100/mm3 or stage B/C disease with CD4 counts of <200/mm3. Patients received tenofovir-emtricitabine with lopinavir-ritonavir (LPV/r) or efavirenz and were randomized to receive ENF for 24 weeks (ENF arm) or not (control arm). The primary endpoint was the proportion of patients with CD4 counts of ≥200/mm3 at week 24. A total of 195 patients were randomized: 73% had stage C disease, 78% were male, the mean age was 44 years, the median CD4 count was 30/mm3, and the median HIV-1 RNA load was 5.4 log10 copies/ml. Eighty-one percent of patients received LPV/r. One patient was lost to follow-up, and eight discontinued the study (four in each arm). The proportions of patients with CD4 counts of ≥200/mm3 at week 24 were 34% and 38% in the ENF and control arms, respectively (P = 0.53). The proportions of patients with HIV-1 RNA loads of <50 copies/ml were 74% and 58% at week 24 in the ENF and control arms, respectively (P < 0.02), and the proportion reached 79% in both arms at week 48. Twenty (20%) and 12 patients (13%) in the ENF and control arms, respectively, experienced at least one AIDS event during follow-up (P = 0.17). Although inducing a more rapid virological response, addition of ENF to a standard cART does not improve the immunological outcome in naive HIV-infected patients with severe immunosuppression. PMID:23165467

  19. Ultraviolet laser-induced lateral photovoltaic response in anisotropic black shale

    NASA Astrophysics Data System (ADS)

    Miao, Xinyang; Zhu, Jing; Zhao, Kun; Yue, Wenzheng

    2017-12-01

    The anisotropy of shale has significant impact on oil and gas exploration and engineering. In this paper, a-248 nm ultraviolet laser was employed to assess the anisotropic lateral photovoltaic (LPV) response of shale. Anisotropic angle-depending voltage signals were observed with different peak amplitudes ( V p) and decay times. We employed exponential models to explain the charge carrier transport in horizontal and vertical directions. Dependences of the laser-induced LPV on the laser spot position were observed. Owing to the Dember effect and the layered structure of shale, V p shows an approximately linear dependence with the laser-irradiated position for the 0° shale sample but nonlinearity for the 45° and 90° ones. The results demonstrate that the laser-induced voltage method is very sensitive to the structure of materials, and thus has a great potential in oil and gas reservoir characterization.

  20. Linear parameter varying identification of ankle joint intrinsic stiffness during imposed walking movements.

    PubMed

    Sobhani Tehrani, Ehsan; Jalaleddini, Kian; Kearney, Robert E

    2013-01-01

    This paper describes a novel model structure and identification method for the time-varying, intrinsic stiffness of human ankle joint during imposed walking (IW) movements. The model structure is based on the superposition of a large signal, linear, time-invariant (LTI) model and a small signal linear-parameter varying (LPV) model. The methodology is based on a two-step algorithm; the LTI model is first estimated using data from an unperturbed IW trial. Then, the LPV model is identified using data from a perturbed IW trial with the output predictions of the LTI model removed from the measured torque. Experimental results demonstrate that the method accurately tracks the continuous-time variation of normal ankle intrinsic stiffness when the joint position changes during the IW movement. Intrinsic stiffness gain decreases from full plantarflexion to near the mid-point of plantarflexion and then increases substantially as the ankle is dosriflexed.

  1. Robustness Analysis of Integrated LPV-FDI Filters and LTI-FTC System for a Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Khong, Thuan H.; Shin, Jong-Yeob

    2007-01-01

    This paper proposes an analysis framework for robustness analysis of a nonlinear dynamics system that can be represented by a polynomial linear parameter varying (PLPV) system with constant bounded uncertainty. The proposed analysis framework contains three key tools: 1) a function substitution method which can convert a nonlinear system in polynomial form into a PLPV system, 2) a matrix-based linear fractional transformation (LFT) modeling approach, which can convert a PLPV system into an LFT system with the delta block that includes key uncertainty and scheduling parameters, 3) micro-analysis, which is a well known robust analysis tool for linear systems. The proposed analysis framework is applied to evaluating the performance of the LPV-fault detection and isolation (FDI) filters of the closed-loop system of a transport aircraft in the presence of unmodeled actuator dynamics and sensor gain uncertainty. The robustness analysis results are compared with nonlinear time simulations.

  2. CEOS WGCV Land Product Validation (LPV) Sub-Group: Current and Potential Roles in Future Decadal Survey Missions

    NASA Technical Reports Server (NTRS)

    Roman, Miguel O.; Nightingale, Joanne; Nickeson, Jaime; Schaepman-Strub, Gabriela

    2011-01-01

    The goals and objectives of the sub group are: To foster and coordinate quantitative validation of higher level global land products derive d from remotely sensed data, in a traceable way, and to relay results so they are relevant to users. and to increase the quality and effi ciency of global satellite product validation by developing and promo ting international standards and protocols for: (1) Field sampling (2) Scaling techniques (3) Accuracy reporting (4) Data / information exchange also to provide feedback to international structures (GEOSS ) for: (1) Requirements on product accuracy and quality assurance (QA 4EO) (2) Terrestrial ECV measurement standards (3) Definitions for f uture missions

  3. Antiretroviral pharmacokinetics in mothers and breastfeeding infants from 6 to 24 weeks post partum: results of the BAN Study

    PubMed Central

    Corbett, Amanda H; Kayira, Dumbani; White, Nicole R; Davis, Nicole L; Kourtis, Athena P; Chasela, Charles; Martinson, Francis; Phiri, Grace; Musisi, Bonaface; Kamwendo, Deborah; Hudgens, Michael G; Hosseinipour, Mina C; Nelson, Julie AE; Ellington, Sascha R; Jamieson, Denise J; van der Horst, Charles; Kashuba, Angela

    2014-01-01

    Background An intensive, prospective, open-label pharmacokinetic (PK) study in a subset of HIV-infected mothers and their uninfected infants enrolled in the Breastfeeding, Antiretroviral, and Nutrition study was performed to describe drug exposure and antiviral response. Methods Women using Combivir®[zidovudine (ZDV)+ lamivudine (3TC)]+Aluvia®[lopinavir/ritonavir(LPV/RTV)] were enrolled. Breast milk (BM) and mother and infant plasma (MP, IP) samples were obtained over 6hrs after observed dosing at 6, 12, or 24wks post-partum for drug concentrations and HIV RNA. Results 30 mother/infant pairs (10 each at 6, 12,and 24wks post-partum) were enrolled. Relative to MP, BM concentrations of ZDV and 3TC were 35% and 21% higher, while LPV and RTV were 80% lower. Only 3TC was detected in IP with concentrations 96% and 98% lower than MP and BM, respectively. Concentrations in all matrices were similar at 6-24wks. The majority (98.3%) of BM concentrations were >HIVwt IC50, with one having detectable virus. There was no association between PK parameters and MP or BM HIV RNA. Conclusions ZDV and 3TC concentrated in BM while LPV and RTV did not, possibly due to protein binding and drug transporter affinity. Undetectable to low ARV concentrations in IP suggests prevention of transmission while breast feeding may be due to ARV effects on systemic or BM HIV RNA in the mother. Low IP 3TC exposure may predispose an infected infant to HIV resistance, necessitating testing and treating infants early. PMID:24464632

  4. Impact of second-line antiretroviral regimens on lipid profiles in an African setting: the DART trial sub-study.

    PubMed

    Gomo, Zvenyika Ar; Hakim, James G; Walker, Sarah A; Tinago, Willard; Mandozana, Gibson; Kityo, Cissy; Munderi, Paula; Katabira, Elly; Reid, Andrew; Gibb, Diana M; Gilks, Charles F

    2014-01-01

    Increasing numbers of HIV-infected patients in sub-Saharan Africa are exposed to antiretroviral therapy (ART), but there are few data on lipid changes on first-line ART, and even fewer on second-line. DART was a randomized trial comparing monitoring strategies in Ugandan/Zimbabwean adults initiating first-line ART and switching to second-line at clinical/immunological failure. We evaluated fasting lipid profiles at second-line initiation and ≥48 weeks subsequently in stored samples from Zimbabwean patients switching before 18 September 2006. Of 91 patients switched to second-line ART, 65(73%) had fasting samples at switch and ≥48 weeks, 14(15%) died or were lost <48 weeks, 10(11%) interrupted ART for >14 days and 2(2%) had no samples available. 56/65(86%) received ZDV/d4T + 3TC + TDF first-line, 6(9%) ZDV/d4T + 3TC + NVP and 3(5%) ZDV + 3TC with TDF and NVP. Initial second-line regimens were LPV/r + NNRTI in 27(41%), LPV/r + NNRTI + ddI in 33(50%) and LPV/r + TDF + ddI/3TC/ZDV in 6(9%). At second-line initiation median (IQR) TC, LDL-C, HDL-C and TG (mmol/L) were 3.3(2.8-4.0), 1.7(1.3-2.2), 0.7(0.6-0.9) and 1.1(0.8-1.9) respectively. Levels were significantly increased 48 weeks later, by mean (SE) +2.0(0.1), +1.1(0.1), +0.5(0.05) and +0.4(0.2) respectively (p < 0.001; TG p = 0.01). 3% at switch vs 25% 48 weeks later had TC >5.2 mmol/L; 3% vs 25% LDL-C >3.4 mmol/L and 91% vs 41% HDL-C <1.1 mmol/L (p < 0.001). Similar proportions had TG >1.8 mmol/L (0 vs 3%) and TC/HDL-C ≥5 (40% vs 33%) (p > 0.15). Modest lipid elevations were observed in African patients on predominantly LPV/r + NNRTI-based second-line regimens. Routine lipid monitoring during second-line ART regimens may not be warranted in this setting but individual cardiovascular risk assessment should guide practice.

  5. Structurally optimized analogs of the retrograde trafficking inhibitor Retro-2cycl limit Leishmania infections.

    PubMed

    Craig, Evan; Huyghues-Despointes, Charles-Eugene; Yu, Chun; Handy, Emma L; Sello, Jason K; Kima, Peter E

    2017-05-01

    In infected mammalian cells, Leishmania parasites reside within specialized compartments called parasitophorous vacuoles (LPVs). We have previously shown that Retro-2, a member of a novel class of small retrograde pathway inhibitors caused reduced LPV sizes and lower parasite numbers during experimental L. mexicana sp. infections. The purpose of this study was to determine if structural analogs of Retro-2cycl reported to have superior potency in the inhibition of retrograde pathway-dependent phenomena (i.e., polyomavirus cellular infection by polyomavrius and Shiga toxin trafficking in cells) are also more effective than the parent compound at controlling Leishmania infections. In addition to their effects on LPV development, we show that two optimized analogs of Retro-2cycl, DHQZ 36 and DHQZ 36.1 limit Leishmania amazonensis infection in macrophages at EC50 of 13.63+/-2.58μM and10.57+/-2.66μM, respectively, which is significantly lower than 40.15μM the EC50 of Retro-2cycl. In addition, these analogs caused a reversal in Leishmania induced suppression of IL-6 release by infected cells after LPS activation. Moreover, we show that in contrast to Retro-2cycl that is Leishmania static, the analogs can kill Leishmania parasites in axenic cultures, which is a desirable attribute for any drug to treat Leishmania infections. Together, these studies validate and extend the published structure-activity relationship analyses of Retro-2cycl.

  6. Evaluation of the rabbit liver by direct portography and contrast-enhanced computed tomography: anatomical variations of the portal system and hepatic volume quantification.

    PubMed

    Páramo, María; García-Barquin, Paula; Santa María, Eva; Madrid, José Miguel; Caballeros, Meylin; Benito, Alberto; Sangro, Bruno; Iñarrairaegui, Mercedes; Bilbao, José Ignacio

    2017-01-01

    The study was aimed at: (1) describing the incidence of anatomic variations of the portal system in the rabbit using direct portography; and (2) estimating the liver volume and caudate lobe volume by using contrast-enhanced computed tomography (CECT) in the same animal model. Forty-six New Zealand white rabbits were included. All of them underwent direct portography and unenhanced CECT. Conventional liver rabbit portal system anatomy (type 1) consisted of the bifurcation of the main portal vein (MPV) into the right portal vein (RPV) and left portal vein (LPV), which subsequently divided into medial left portal vein and lateral left portal vein. Trifurcation of the LPV was considered type 2. The LPV that divides into four smaller branches was classified as type 3. Other configurations of the portal system, including particular cases of MPV branching, were grouped as type 4. Liver lobes were manually segmented. The incidence of each type of portal system anatomy was: type 1, 67.4%; type 2, 15.2%; type 3, 13.0%); and type 4, 4.3%. The mean volume of the caudate lobe was 19.1 ml ± 5.7 ml and of the cranial lobes it was 66.7 ml ± 13.7 ml, and the total liver volume was 85.7 ml ± 16.7 ml. In New Zealand white rabbits, type 1 is the prevalent type of portal system, liver volume is about 86 ml, and the caudate and cranial lobes are separated. This information could be important when planning experimental rabbit liver procedures.

  7. A new method for CT dose estimation by determining patient water equivalent diameter from localizer radiographs: Geometric transformation and calibration methods using readily available phantoms.

    PubMed

    Zhang, Da; Mihai, Georgeta; Barbaras, Larry G; Brook, Olga R; Palmer, Matthew R

    2018-05-10

    Water equivalent diameter (Dw) reflects patient's attenuation and is a sound descriptor of patient size, and is used to determine size-specific dose estimator from a CT examination. Calculating Dw from CT localizer radiographs makes it possible to utilize Dw before actual scans and minimizes truncation errors due to limited reconstructed fields of view. One obstacle preventing the user community from implementing this useful tool is the necessity to calibrate localizer pixel values so as to represent water equivalent attenuation. We report a practical method to ease this calibration process. Dw is calculated from water equivalent area (Aw) which is deduced from the average localizer pixel value (LPV) of the line(s) in the localizer radiograph that correspond(s) to the axial image. The calibration process is conducted to establish the relationship between Aw and LPV. Localizer and axial images were acquired from phantoms of different total attenuation. We developed a program that automates the geometrical association between axial images and localizer lines and manages the measurements of Dw and average pixel values. We tested the calibration method on three CT scanners: a GE CT750HD, a Siemens Definition AS, and a Toshiba Acquilion Prime80, for both posterior-anterior (PA) and lateral (LAT) localizer directions (for all CTs) and with different localizer filters (for the Toshiba CT). The computer program was able to correctly perform the geometrical association between corresponding axial images and localizer lines. Linear relationships between Aw and LPV were observed (with R 2 all greater than 0.998) on all tested conditions, regardless of the direction and image filters used on the localizer radiographs. When comparing LAT and PA directions with the same image filter and for the same scanner, the slope values were close (maximum difference of 0.02 mm), and the intercept values showed larger deviations (maximum difference of 2.8 mm). Water equivalent diameter estimation on phantoms and patients demonstrated high accuracy of the calibration: percentage difference between Dw from axial images and localizers was below 2%. With five clinical chest examinations and five abdominal-pelvic examinations of varying patient sizes, the maximum percentage difference was approximately 5%. Our study showed that Aw and LPV are highly correlated, providing enough evidence to allow for the Dw determination once the experimental calibration process is established. © 2018 American Association of Physicists in Medicine.

  8. Hierarchical design of an electro-hydraulic actuator based on robust LPV methods

    NASA Astrophysics Data System (ADS)

    Németh, Balázs; Varga, Balázs; Gáspár, Péter

    2015-08-01

    The paper proposes a hierarchical control design of an electro-hydraulic actuator, which is used to improve the roll stability of vehicles. The purpose of the control system is to generate a reference torque, which is required by the vehicle dynamic control. The control-oriented model of the actuator is formulated in two subsystems. The high-level hydromotor is described in a linear form, while the low-level spool valve is a polynomial system. These subsystems require different control strategies. At the high level, a linear parameter-varying control is used to guarantee performance specifications. At the low level, a control Lyapunov-function-based algorithm, which creates discrete control input values of the valve, is proposed. The interaction between the two subsystems is guaranteed by the spool displacement, which is control input at the high level and must be tracked at the low-level control. The spool displacement has physical constraints, which must also be incorporated into the control design. The robust design of the high-level control incorporates the imprecision of the low-level control as an uncertainty of the system.

  9. Expeditionary Warfare Division Meeting (10th) Held in Panama City, Florida on 24-27 October 2005

    DTIC Science & Technology

    2005-10-01

    Seabasing a TRANSCOM Perspective, by Captain Craig Galloway, USN, US Transportation Command, J5A DLA Afloat, by Col Jeff Hill, Chief, Distribution ... Management Division, Defense Logistics Agency Sustaining the Seabase a View…, by Mr. Nicholas Linkowitz, HQMC I&L (Code LPV) Sustaining the Sea Base

  10. Artemisinin-based combination therapies are efficacious and safe for treatment of uncomplicated malaria in HIV-infected Ugandan children.

    PubMed

    Kakuru, Abel; Achan, Jane; Muhindo, Mary K; Ikilezi, Gloria; Arinaitwe, Emmanuel; Mwangwa, Florence; Ruel, Theodore; Clark, Tamara D; Charlebois, Edwin; Rosenthal, Philip J; Havlir, Diane; Kamya, Moses R; Tappero, Jordan W; Dorsey, Grant

    2014-08-01

    Artemisinin-based combination therapies (ACTs) are highly efficacious and safe, but data from human immunodeficiency virus (HIV)-infected children concurrently receiving antiretroviral therapy (ART) and ACTs are limited. We evaluated 28-day outcomes following malaria treatment with artemether-lumefantrine (AL) or dihydroartemisinin-piperaquine (DP) in 2 cohorts of HIV-infected Ugandan children taking various ART regimens. In one cohort, children <6 years of age were randomized to lopinavir/ritonavir (LPV/r) or nonnucleoside reverse transcriptase inhibitor-based ART and treated with AL for uncomplicated malaria. In another cohort, children <12 months of age were started on nevirapine-based ART if they were eligible, and randomized to AL or DP for the treatment of their first and all subsequent uncomplicated malaria episodes. There were 773 and 165 treatments for malaria with AL and DP, respectively. Initial response to therapy was excellent, with 99% clearance of parasites and <1% risk of repeat therapy within 3 days. Recurrent parasitemia within 28 days was common following AL treatment. The risk of recurrent parasitemia was significantly lower among children taking LPV/r-based ART compared with children taking nevirapine-based ART following AL treatment (15.3% vs 35.5%, P = .009), and those treated with DP compared with AL (8.6% vs 36.2%, P < .001). Both ACT regimens were safe and well tolerated. Treatment of uncomplicated malaria with AL or DP was efficacious and safe in HIV-infected children taking ART. However, there was a high risk of recurrent parasitemia following AL treatment, which was significantly lower in children taking LPV/r-based ART compared with nevirapine-based ART. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  11. Variable effectiveness of stepwise implementation of nudge-type interventions to improve provider compliance with intraoperative low tidal volume ventilation.

    PubMed

    O'Reilly-Shah, Vikas N; Easton, George S; Jabaley, Craig S; Lynde, Grant C

    2018-05-18

    Identifying mechanisms to improve provider compliance with quality metrics is a common goal across medical disciplines. Nudge interventions are minimally invasive strategies that can influence behavioural changes and are increasingly used within healthcare settings. We hypothesised that nudge interventions may improve provider compliance with lung-protective ventilation (LPV) strategies during general anaesthesia. We developed an audit and feedback dashboard that included information on both provider-level and department-level compliance with LPV strategies in two academic hospitals, two non-academic hospitals and two academic surgery centres affiliated with a single healthcare system. Dashboards were emailed to providers four times over the course of the 9-month study. Additionally, the default setting on anaesthesia machines for tidal volume was decreased from 700 mL to 400 mL. Data on surgical cases performed between 1 September 2016 and 31 May 2017 were examined for compliance with LPV. The impact of the interventions was assessed via pairwise logistic regression analysis corrected for multiple comparisons. A total of 14 793 anaesthesia records were analysed. Absolute compliance rates increased from 59.3% to 87.8%preintervention to postintervention. Introduction of attending physician dashboards resulted in a 41% increase in the odds of compliance (OR 1.41, 95% CI 1.17 to 1.69, p=0.002). Subsequently, the addition of advanced practice provider and resident dashboards lead to an additional 93% increase in the odds of compliance (OR 1.93, 95% CI 1.52 to 2.46, p<0.001). Lastly, modifying ventilator defaults led to a 376% increase in the odds of compliance (OR 3.76, 95% CI 3.1 to 4.57, p<0.001). Audit and feedback tools in conjunction with default changes improve provider compliance. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Evaluation of MODIS and VIIRS Albedo Products Using Ground and Airborne Measurements and Development of Ceos/Wgcv/Lpv Albedo Ecv Protocols

    NASA Astrophysics Data System (ADS)

    Wang, Z.; Roman, M. O.; Schaaf, C.; Sun, Q.; Liu, Y.; Saenz, E. J.; Gatebe, C. K.

    2014-12-01

    Surface albedo, defined as the ratio of the hemispheric reflected solar radiation flux to the incident flux upon the surface, is one of the essential climate variables and quantifies the radiation interaction between the atmosphere and the land surface. An absolute accuracy of 0.02-0.05 for global surface albedo is required by climate models. The MODerate resolution Imaging Spectroradiometer (MODIS) standard BRDF/albedo product makes use of a linear "kernel-driven" RossThick-LiSparse Reciprocal (RTLSR) BRDF model to describe the reflectance anisotropy. The surface albedo is calculated by integrating the BRDF over the above ground hemisphere. While MODIS Terra was launched in Dec 1999 and MODIS Aqua in 2002, the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi-NPP satellite was launched more recently on October 28, 2011. Thus a long term record of BRDF, albedo and Nadir BRDF-Adjusted Reflectance (NBAR) products from VIIRS can be generated through MODIS heritage algorithms. Several investigations have evaluated the MODIS albedo products during the growing season, as well as during dormant and snow covered periods. The Land Product Validation (LPV) sub-group of the Committee on Earth Observation Satellites (CEOS) Working Group on Calibration and Validation (WGCV) aims to address the challenges associated with the validation of global land products. The validation of global surface radiation/albedo products is one of the LPV subgroup activities. In this research, a reference dataset covering various land surface types and vegetation structure is assembled to assess the accuracy of satellite albedo products. This dataset includes in situ data (Baseline Surface Radiation Network (BSRN), FLUXNET and Long Term Ecological Research network (LTER) etc.) and airborne measurements (e.g. Cloud Absorption Radiometer (CAR)). Spatially representative analysis is applied to each site to establish whether the ground measurements can adequately represent moderate spatial resolution remotely sensed albedo products.

  13. Integrated control design for driver assistance systems based on LPV methods

    NASA Astrophysics Data System (ADS)

    Gáspár, Péter; Németh, Balázs

    2016-12-01

    The paper proposes a control design method for a driver assistance system. In the operation of the system, a predefined trajectory required by the driver with a steering command is followed. During manoeuvres the control system generates differential brake moment and the auxiliary front-wheel steering angle and changes the camber angles of the wheels in order to improve the tracking of the road trajectory. The performance specifications are guaranteed by the local controllers, i.e. the brake, the steering, and the suspension systems, while the coordination of these components is provided by the supervisor. The advantage of this architecture is that local controllers are designed independently, which is ensured by the fact that the monitoring signals are taken into consideration in the formalisation of their performance specifications. The fault-tolerant control can be achieved by incorporating the detected fault signals in their performance specifications. The control system also uses a driver model, with which the reference signal can be generated. In the control design, the parameter-dependent linear parameter-varyingmethod, which meets the performance specifications, is used. The operation of the control system is illustrated through different normal and emergency vehicle manoeuvres with a high-accuracy simulation software.

  14. An LPV Adaptive Observer for Updating a Map Applied to an MAF Sensor in a Diesel Engine.

    PubMed

    Liu, Zhiyuan; Wang, Changhui

    2015-10-23

    In this paper, a new method for mass air flow (MAF) sensor error compensation and an online updating error map (or lookup table) due to installation and aging in a diesel engine is developed. Since the MAF sensor error is dependent on the engine operating point, the error model is represented as a two-dimensional (2D) map with two inputs, fuel mass injection quantity and engine speed. Meanwhile, the 2D map representing the MAF sensor error is described as a piecewise bilinear interpolation model, which can be written as a dot product between the regression vector and parameter vector using a membership function. With the combination of the 2D map regression model and the diesel engine air path system, an LPV adaptive observer with low computational load is designed to estimate states and parameters jointly. The convergence of the proposed algorithm is proven under the conditions of persistent excitation and given inequalities. The observer is validated against the simulation data from engine software enDYNA provided by Tesis. The results demonstrate that the operating point-dependent error of the MAF sensor can be approximated acceptably by the 2D map from the proposed method.

  15. Studies of hydrodynamic events in stellar evolution. 3: Ejection of planetary nebulae

    NASA Technical Reports Server (NTRS)

    Sparks, W. M.; Kutter, G. S.

    1973-01-01

    The dynamic behavior of the H-rich envelope (0.101 solar mass) of an evolved star (1.1 solar mass) as the luminosity rises to 19000 solar luminosity during the second ascent of the red giant branch. For luminosities in the range 3100 L 19000 solar luminosity the H-rich envelope pulsates like a long-period variable (LPV) with periods of the order of a year. As L reaches 19000 solar luminosity, the entire H-rich envelope is ejected as a shell with speeds of a few 10 km/s. The ejection occurs on a timescale of a few LPV pulsation periods. This ejection is associated with the formation of a planetary nebula. The computations are based on an implicit hydrodynamic computer code. T- and RHO-dependent opacities and excitation and ionization energies are included. As the H-rich envelope is accelerated off the stellar core, the gap between envelope and core is approximated by a vacuum, filled with radiation. Across the vacuum, the luminosity is conserved and the anisotropy of the radiation is considered as well as the solid angle subtended by the remnant star at the inner surface of the H-rich envelope. Spherical symmetry and the diffusion approximation are assumed.

  16. Selected considerations of implementation of the GNSS

    NASA Astrophysics Data System (ADS)

    Cwiklak, Janusz; Fellner, Andrzej; Fellner, Radoslaw; Jafernik, Henryk; Sledzinski, Janusz

    2014-05-01

    The article describes analysis of the safety and risk for the implementation of precise approach procedures (Localizer Performance and Vertical Guidance - LPV) with GNSS sensor at airports in Warsaw and Katowice. There were used some techniques of the identification of threats (inducing controlled flight into terrain, landing accident, mid-air collision) and evaluations methods based on Fault Tree Analysis, probability of the risk, safety risk evaluation matrix and Functional Hazard Assesment. Also safety goals were determined. Research led to determine probabilities of appearing of threats, as well as allow compare them with regard to the ILS. As a result of conducting the Preliminary System Safety Assessment (PSSA), there were defined requirements essential to reach the required level of the safety. It is worth to underline, that quantitative requirements were defined using FTA.

  17. Size-dependent magnetic tuning of lateral photovoltaic effect in nonmagnetic Si-based Schottky junctions

    PubMed Central

    Zhou, Peiqi; Gan, Zhikai; Huang, Xu; Mei, Chunlian; Xia, Yuxing; Wang, Hui

    2017-01-01

    In this article, we report a magnetic tuning lateral photovoltaic effect (LPE) in a nonmagnetic Si-based Schottky junctions. In the magnetic field intensity range of 0 to 1.6 T, the variation amplitude of LPE sensitivity is as high as 94.8%, the change of LPV is and the change rate of lateral photo-voltage even reaches 520 mV/T at 1.5 T, which is apparently higher than the results of previous reported researches in magnetic materials. This effect is attributed to the combined result of the influence of magnetic field on diffusion current and the rectification property of our anisotropic structure. This work may expand the application of LPE in magnetism field such as magnetic sensor and magnetoresistance, and it suggests a new way to investigate the carrier transport in Schottky junctions under magnetic field. PMID:28397819

  18. Aircraft engine sensor fault diagnostics using an on-line OBEM update method.

    PubMed

    Liu, Xiaofeng; Xue, Naiyu; Yuan, Ye

    2017-01-01

    This paper proposed a method to update the on-line health reference baseline of the On-Board Engine Model (OBEM) to maintain the effectiveness of an in-flight aircraft sensor Fault Detection and Isolation (FDI) system, in which a Hybrid Kalman Filter (HKF) was incorporated. Generated from a rapid in-flight engine degradation, a large health condition mismatch between the engine and the OBEM can corrupt the performance of the FDI. Therefore, it is necessary to update the OBEM online when a rapid degradation occurs, but the FDI system will lose estimation accuracy if the estimation and update are running simultaneously. To solve this problem, the health reference baseline for a nonlinear OBEM was updated using the proposed channel controller method. Simulations based on the turbojet engine Linear-Parameter Varying (LPV) model demonstrated the effectiveness of the proposed FDI system in the presence of substantial degradation, and the channel controller can ensure that the update process finishes without interference from a single sensor fault.

  19. Aircraft engine sensor fault diagnostics using an on-line OBEM update method

    PubMed Central

    Liu, Xiaofeng; Xue, Naiyu; Yuan, Ye

    2017-01-01

    This paper proposed a method to update the on-line health reference baseline of the On-Board Engine Model (OBEM) to maintain the effectiveness of an in-flight aircraft sensor Fault Detection and Isolation (FDI) system, in which a Hybrid Kalman Filter (HKF) was incorporated. Generated from a rapid in-flight engine degradation, a large health condition mismatch between the engine and the OBEM can corrupt the performance of the FDI. Therefore, it is necessary to update the OBEM online when a rapid degradation occurs, but the FDI system will lose estimation accuracy if the estimation and update are running simultaneously. To solve this problem, the health reference baseline for a nonlinear OBEM was updated using the proposed channel controller method. Simulations based on the turbojet engine Linear-Parameter Varying (LPV) model demonstrated the effectiveness of the proposed FDI system in the presence of substantial degradation, and the channel controller can ensure that the update process finishes without interference from a single sensor fault. PMID:28182692

  20. An LPV Adaptive Observer for Updating a Map Applied to an MAF Sensor in a Diesel Engine

    PubMed Central

    Liu, Zhiyuan; Wang, Changhui

    2015-01-01

    In this paper, a new method for mass air flow (MAF) sensor error compensation and an online updating error map (or lookup table) due to installation and aging in a diesel engine is developed. Since the MAF sensor error is dependent on the engine operating point, the error model is represented as a two-dimensional (2D) map with two inputs, fuel mass injection quantity and engine speed. Meanwhile, the 2D map representing the MAF sensor error is described as a piecewise bilinear interpolation model, which can be written as a dot product between the regression vector and parameter vector using a membership function. With the combination of the 2D map regression model and the diesel engine air path system, an LPV adaptive observer with low computational load is designed to estimate states and parameters jointly. The convergence of the proposed algorithm is proven under the conditions of persistent excitation and given inequalities. The observer is validated against the simulation data from engine software enDYNA provided by Tesis. The results demonstrate that the operating point-dependent error of the MAF sensor can be approximated acceptably by the 2D map from the proposed method. PMID:26512675

  1. Analysis of single-nucleotide polymorphisms (SNPs) in human CYP3A4 and CYP3A5 genes: potential implications for the metabolism of HIV drugs

    PubMed Central

    2014-01-01

    Background Drug metabolism via the cytochrome P450 (CYP450) system has emerged as an important determinant in the occurrence of several drug interactions (adverse drug reactions, reduced pharmacological effect, drug toxicities). In particular, CYP3A4 and CYP3A5 (interacting with more than 60% of licensed drugs) exhibit the most individual variations of gene expression, mostly caused by single nucleotide polymorphisms (SNPs) within the regulatory region of the CYP3A4 and CYP3A5 genes which might affect the level of enzyme production. In this study, we sought to improve the performance of sensitive screening for CYP3A polymorphism detection in twenty HIV-1 infected patients undergoing lopinavir/ritonavir (LPV/r) monotherapy. Methods The study was performed by an effective, easy and inexpensive home-made Polymerase Chain Reaction Direct Sequencing approach for analyzing CYP3A4 and CYP3A5 genes which can detect both reported and unreported genetic variants potentially associated with altered or decreased functions of CYP3A4 and CYP3A5 proteins. Proportions and tests of association were used. Results Among the genetic variants considered, CYP3A4*1B (expression of altered function) was only found in 3 patients (15%) and CYP3A5*3 (expression of splicing defect) in 3 other patients (15%). CYP3A5*3 did not appear to be associated with decreased efficacy of LPV/r in any patient, since none of the patients carrying this variant showed virological rebound during LPV/r treatment or low levels of TDM. In contrast, low-level virological rebound was observed in one patient and a low TDM level was found in another; both were carrying CYP3A4*1B. Conclusions Our method exhibited an overall efficiency of 100% (DNA amplification and sequencing in our group of patients). This may contribute to producing innovative results for better understanding the inter-genotypic variability in gene coding for CYP3A, and investigating SNPs as biological markers of individual response to drugs requiring metabolism via the cytochrome P450 system. PMID:24986243

  2. Carfilzomib resistance due to ABCB1/MDR1 overexpression is overcome by nelfinavir and lopinavir in multiple myeloma

    PubMed Central

    Besse, A; Stolze, S C; Rasche, L; Weinhold, N; Morgan, G J; Kraus, M; Bader, J; Overkleeft, H S; Besse, L; Driessen, C

    2018-01-01

    Proteasome inhibitor (PI) carfilzomib (CFZ) has activity superior to bortezomib (BTZ) and is increasingly incorporated in multiple myeloma (MM) frontline therapy and relapsed settings. Most MM patients ultimately experience PI-refractory disease, an unmet medical need with poorly understood biology and dismal outcome. Pharmacologic targeting of ABCB1 improved patient outcomes, including MM, but suffered from adverse drug effects and insufficient plasma concentrations. Proteomics analysis identified ABCB1 overexpression as the most significant change in CFZ-resistant MM cells. We addressed the functional role of ABCB1 overexpression in MM and observed significantly upregulated ABCB1 in peripheral blood malignant plasma cells (PCs) vs untreated patients’ bone marrow PC. ABCB1 overexpression reduces the proteasome-inhibiting activity of CFZ due to drug efflux, in contrast to BTZ. Likewise, the cytotoxicity of established anti-MM drugs was significantly reduced in ABCB1-expressing MM cells. In search for potential drugs targeting ABCB1 in clinical trials, we identified the HIV protease inhibitors nelfinavir (NFV) and lopinavir (LPV) as potent functional modulators of ABCB1-mediated drug export, most likely via modulation of mitochondria permeability transition pore. NFV and LPV restored CFZ activity at therapeutically relevant drug levels and thus represent ready-to-use drugs to be tested in clinical trials to target ABCB1 and to re-sensitize PC to established myeloma drugs, in particular CFZ. PMID:28676669

  3. Atmospheric extinction in solar tower plants: absorption and broadband correction for MOR measurements

    NASA Astrophysics Data System (ADS)

    Hanrieder, N.; Wilbert, S.; Pitz-Paal, R.; Emde, C.; Gasteiger, J.; Mayer, B.; Polo, J.

    2015-08-01

    Losses of reflected Direct Normal Irradiance due to atmospheric extinction in concentrated solar tower plants can vary significantly with site and time. The losses of the direct normal irradiance between the heliostat field and receiver in a solar tower plant are mainly caused by atmospheric scattering and absorption by aerosol and water vapor concentration in the atmospheric boundary layer. Due to a high aerosol particle number, radiation losses can be significantly larger in desert environments compared to the standard atmospheric conditions which are usually considered in ray-tracing or plant optimization tools. Information about on-site atmospheric extinction is only rarely available. To measure these radiation losses, two different commercially available instruments were tested, and more than 19 months of measurements were collected and compared at the Plataforma Solar de Almería. Both instruments are primarily used to determine the meteorological optical range (MOR). The Vaisala FS11 scatterometer is based on a monochromatic near-infrared light source emission and measures the strength of scattering processes in a small air volume mainly caused by aerosol particles. The Optec LPV4 long-path visibility transmissometer determines the monochromatic attenuation between a light-emitting diode (LED) light source at 532 nm and a receiver and therefore also accounts for absorption processes. As the broadband solar attenuation is of interest for solar resource assessment for concentrated solar power (CSP), a correction procedure for these two instruments is developed and tested. This procedure includes a spectral correction of both instruments from monochromatic to broadband attenuation. That means the attenuation is corrected for the time-dependent solar spectrum which is reflected by the collector. Further, an absorption correction for the Vaisala FS11 scatterometer is implemented. To optimize the absorption and broadband correction (ABC) procedure, additional measurement input of a nearby sun photometer is used to enhance on-site atmospheric assumptions for description of the atmosphere in the algorithm. Comparing both uncorrected and spectral- and absorption-corrected extinction data from 1-year measurements at the Plataforma Solar de Almería, the mean difference between the scatterometer and the transmissometer is reduced from 4.4 to 0.57 %. Applying the ABC procedure without the usage of additional input data from a sun photometer still reduces the difference between both sensors to about 0.8 %. Applying an expert guess assuming a standard aerosol profile for continental regions instead of additional sun photometer input results in a mean difference of 0.8 %. Additionally, a simulation approach which just uses sun photometer and common meteorological data to determine the on-site atmospheric extinction at surface is presented and corrected FS11 and LPV4 measurements are validated with the simulation results. For T1 km equal to 0.9 and a 10 min time resolution, an uncertainty analysis showed that an absolute uncertainty of about 0.038 is expected for the FS11 and about 0.057 for the LPV4. Combining both uncertainties results in an overall absolute uncertainty of 0.068 which justifies quite well the mean RMSE between both corrected data sets. For yearly averages several error influences average out and absolute uncertainties of 0.020 and 0.054 can be expected for the FS11 and the LPV4, respectively. Therefore, applying this new correction method, both instruments can now be utilized to sufficiently accurately determine the solar broadband extinction in tower plants.

  4. Parallel ultra high pressure liquid chromatography-mass spectrometry for the quantification of HIV protease inhibitors using dried spot sample collection format.

    PubMed

    Watanabe, Kyoko; Varesio, Emmanuel; Hopfgartner, Gérard

    2014-08-15

    An assay was developed and validated for the quantification of eight protease inhibitors (indinavir (IDV), ritonavir (RTV), lopinavir (LPV), saquinavir (SQV), amprenavir (APV), nelfinavir (NFV), atazanavir (AZV) and darunavir (DRV)) in dried plasma spots using parallel ultra-high performance liquid chromatography and mass spectrometry detection in the multiple reaction monitoring mode. For each analyte an isotopically labeled internal standard was used and the assay based on liquid-solid extraction the area response ratio (analyte/IS) was found to be linear; from 0.025 μg/ml to 20 μg/ml for IDV, SQV, DRV, AZV, LPV, from 0.025 μg/ml to 10 μg/ml for NFV, APV and from 0.025 μg/ml to 5 μg/ml for RTV using 15 μl of plasma spotted on filter paper placed in a sample tube. The total analysis time was of 4 min and inter-assay accuracies and precisions were in the range of 87.7-109% and 2.5-11.8%, respectively. On dried plasma spots all analytes were found to be stable for at least 7 days. Practicability of the assay to blood was also demonstrated. The sample drying process could be reduced to 5 min using a commercial microwave system without any analyte degradation. Together with quantification, confirmatory analysis was performed on representative clinical samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. An automated system for the analysis of G protein-coupled receptor transmembrane binding pockets: alignment, receptor-based pharmacophores, and their application.

    PubMed

    Kratochwil, Nicole A; Malherbe, Pari; Lindemann, Lothar; Ebeling, Martin; Hoener, Marius C; Mühlemann, Andreas; Porter, Richard H P; Stahl, Martin; Gerber, Paul R

    2005-01-01

    G protein-coupled receptors (GPCRs) share a common architecture consisting of seven transmembrane (TM) domains. Various lines of evidence suggest that this fold provides a generic binding pocket within the TM region for hosting agonists, antagonists, and allosteric modulators. Here, a comprehensive and automated method allowing fast analysis and comparison of these putative binding pockets across the entire GPCR family is presented. The method relies on a robust alignment algorithm based on conservation indices, focusing on pharmacophore-like relationships between amino acids. Analysis of conservation patterns across the GPCR family and alignment to the rhodopsin X-ray structure allows the extraction of the amino acids lining the TM binding pocket in a so-called ligand binding pocket vector (LPV). In a second step, LPVs are translated to simple 3D receptor pharmacophore models, where each amino acid is represented by a single spherical pharmacophore feature and all atomic detail is omitted. Applications of the method include the assessment of selectivity issues, support of mutagenesis studies, and the derivation of rules for focused screening to identify chemical starting points in early drug discovery projects. Because of the coarseness of this 3D receptor pharmacophore model, however, meaningful scoring and ranking procedures of large sets of molecules are not justified. The LPV analysis of the trace amine-associated receptor family and its experimental validation is discussed as an example. The value of the 3D receptor model is demonstrated for a class C GPCR family, the metabotropic glutamate receptors.

  6. Kinetics of microbial translocation markers in patients on efavirenz or lopinavir/r based antiretroviral therapy.

    PubMed

    Vesterbacka, Jan; Nowak, Piotr; Barqasho, Babilonia; Abdurahman, Samir; Nyström, Jessica; Nilsson, Staffan; Funaoka, Hiroyuki; Kanda, Tatsuo; Andersson, Lars-Magnus; Gisslèn, Magnus; Sönnerborg, Anders

    2013-01-01

    We investigated whether there are differences in the effects on microbial translocation (MT) and enterocyte damage by different antiretroviral therapy (ART) regimens after 1.5 years and whether antibiotic use has impact on MT. In a randomized clinical trial (NCT01445223) on first line ART, patients started either lopinavir/r (LPV/r) (n = 34) or efavirenz (EFV) containing ART (n = 37). Lipopolysaccharide (LPS), sCD14, anti-flagellin antibodies and intestinal fatty acid binding protein (I-FABP) levels were determined in plasma at baseline (BL) and week 72 (w72). The levels of LPS and sCD14 were reduced from BL to w72 (157.5 pg/ml vs. 140.0 pg/ml, p = 0.0003; 3.13 ug/ml vs. 2.85 ug/ml, p = 0.005, respectively). The levels of anti-flagellin antibodies had decreased at w72 (0.35 vs 0.31 [OD]; p<0.0004), although significantly only in the LPV/r arm. I-FABP levels increased at w72 (2.26 ng/ml vs 3.13 ng/ml; p<0.0001), although significantly in EFV treated patients only. Patients given antibiotics at BL had lower sCD14 levels at w72 as revealed by ANCOVA compared to those who did not receive (Δ = -0.47 µg/ml; p = 0.015). Markers of MT and enterocyte damage are elevated in untreated HIV-1 infected patients. Long-term ART reduces the levels, except for I-FABP which role as a marker of MT is questionable in ART-experienced patients. Why the enterocyte damage seems to persist remains to be established. Also antibiotic usage may influence the kinetics of the markers of MT. ClinicalTrials.gov NCT01445223.

  7. Pharmacokinetics of Tenofovir Alafenamide When Co-administered With Other HIV Antiretrovirals.

    PubMed

    Begley, Rebecca; Das, Moupali; Zhong, Lijie; Ling, John; Kearney, Brian P; Custodio, Joseph M

    2018-04-10

    Tenofovir alafenamide (TAF), a prodrug of the nucleotide analogue tenofovir (TFV), is an antiretroviral (ARV) agent approved either as a complete regimen (elvitegravir/cobicistat/emtricitabine (F)/tenofovir alafenamide (TAF), rilpivirine/F/TAF, bictegravir/F/TAF), or for use with other ARVs (F/TAF), for treatment of HIV. TAF is a substrate of P-glycoprotein (P-gp) and breast cancer resistance protein (BCRP) transporters. Disposition of TAF may be altered by co-medications that can inhibit or induce P-gp or BCRP transporters. The effects of ARVs on the pharmacokinetics (PK) of TAF were evaluated in 3 studies. Healthy participants received TAF administered alone or with rilpivirine (RPV) in study 1; with dolutegravir (DTG), ritonavir boosted atazanavir (ATV+RTV), lopinavir (LPV/RTV), or darunavir (DRV+RTV) in study 2; and with the pharmacokinetic enhancer cobicistat (COBI), or efavirenz (EFV) in study 3. Across the three studies, 98 participants received treatment with TAF and a coadministered agent (n=10-34/cohort). All study treatments were well tolerated. TAF and TFV exposures were unaffected following co-administration with RPV and DTG. Co-administration with Pgp/BCRP inhibitors such as COBI or PI based regimens (ATV+RTV, LPV/r or DRV+RTV) resulted in a range of 6% to 183% increases in TAF and 105% to 316% increases in TFV exposure, while co-administration with a Pgp inducer, EFV, resulted in a 15% to 24% decrease in TAF and TFV exposure. Evaluation of the drug interaction between TAF and other commonly prescribed boosted and unboosted ARVs provides characterization of the susceptibility of TAF and/or TFV PK to inhibitors or inducers of Pgp/BCRP transporters.

  8. Greedy Sampling and Incremental Surrogate Model-Based Tailoring of Aeroservoelastic Model Database for Flexible Aircraft

    NASA Technical Reports Server (NTRS)

    Wang, Yi; Pant, Kapil; Brenner, Martin J.; Ouellette, Jeffrey A.

    2018-01-01

    This paper presents a data analysis and modeling framework to tailor and develop linear parameter-varying (LPV) aeroservoelastic (ASE) model database for flexible aircrafts in broad 2D flight parameter space. The Kriging surrogate model is constructed using ASE models at a fraction of grid points within the original model database, and then the ASE model at any flight condition can be obtained simply through surrogate model interpolation. The greedy sampling algorithm is developed to select the next sample point that carries the worst relative error between the surrogate model prediction and the benchmark model in the frequency domain among all input-output channels. The process is iterated to incrementally improve surrogate model accuracy till a pre-determined tolerance or iteration budget is met. The methodology is applied to the ASE model database of a flexible aircraft currently being tested at NASA/AFRC for flutter suppression and gust load alleviation. Our studies indicate that the proposed method can reduce the number of models in the original database by 67%. Even so the ASE models obtained through Kriging interpolation match the model in the original database constructed directly from the physics-based tool with the worst relative error far below 1%. The interpolated ASE model exhibits continuously-varying gains along a set of prescribed flight conditions. More importantly, the selected grid points are distributed non-uniformly in the parameter space, a) capturing the distinctly different dynamic behavior and its dependence on flight parameters, and b) reiterating the need and utility for adaptive space sampling techniques for ASE model database compaction. The present framework is directly extendible to high-dimensional flight parameter space, and can be used to guide the ASE model development, model order reduction, robust control synthesis and novel vehicle design of flexible aircraft.

  9. Racemic synthesis and solid phase peptide synthesis application of the chimeric valine/leucine derivative 2-amino-3,3,4-trimethyl-pentanoic acid.

    PubMed

    Pelà, M; Del Zoppo, L; Allegri, L; Marzola, E; Ruzza, C; Calo, G; Perissutti, E; Frecentese, F; Salvadori, S; Guerrini, R

    2014-07-01

    The synthesis of non natural amino acid 2-amino-3,3,4-trimethyl-pentanoic acid (Ipv) ready for solid phase peptide synthesis has been developed. Copper (I) chloride Michael addition, followed by a Curtius rearrangement are the key steps for the lpv synthesis. The racemic valine/leucine chimeric amino acid was then successfully inserted in position 5 of neuropeptide S (NPS) and the diastereomeric mixture separated by reverse phase HPLC. The two diastereomeric NPS derivatives were tested for intracellular calcium mobilization using HEK293 cells stably expressing the mouse NPS receptor where they behaved as partial agonist and pure antagonist.

  10. Fault detection for discrete-time LPV systems using interval observers

    NASA Astrophysics Data System (ADS)

    Zhang, Zhi-Hui; Yang, Guang-Hong

    2017-10-01

    This paper is concerned with the fault detection (FD) problem for discrete-time linear parameter-varying systems subject to bounded disturbances. A parameter-dependent FD interval observer is designed based on parameter-dependent Lyapunov and slack matrices. The design method is presented by translating the parameter-dependent linear matrix inequalities (LMIs) into finite ones. In contrast to the existing results based on parameter-independent and diagonal Lyapunov matrices, the derived disturbance attenuation, fault sensitivity and nonnegative conditions lead to less conservative LMI characterisations. Furthermore, without the need to design the residual evaluation functions and thresholds, the residual intervals generated by the interval observers are used directly for FD decision. Finally, simulation results are presented for showing the effectiveness and superiority of the proposed method.

  11. LPV Modeling of a Flexible Wing Aircraft Using Modal Alignment and Adaptive Gridding Methods

    NASA Technical Reports Server (NTRS)

    Al-Jiboory, Ali Khudhair; Zhu, Guoming; Swei, Sean Shan-Min; Su, Weihua; Nguyen, Nhan T.

    2017-01-01

    One of the earliest approaches in gain-scheduling control is the gridding based approach, in which a set of local linear time-invariant models are obtained at various gridded points corresponding to the varying parameters within the flight envelop. In order to ensure smooth and effective Linear Parameter-Varying control, aligning all the flexible modes within each local model and maintaining small number of representative local models over the gridded parameter space are crucial. In addition, since the flexible structural models tend to have large dimensions, a tractable model reduction process is necessary. In this paper, the notion of s-shifted H2- and H Infinity-norm are introduced and used as a metric to measure the model mismatch. A new modal alignment algorithm is developed which utilizes the defined metric for aligning all the local models over the entire gridded parameter space. Furthermore, an Adaptive Grid Step Size Determination algorithm is developed to minimize the number of local models required to represent the gridded parameter space. For model reduction, we propose to utilize the concept of Composite Modal Cost Analysis, through which the collective contribution of each flexible mode is computed and ranked. Therefore, a reduced-order model is constructed by retaining only those modes with significant contribution. The NASA Generic Transport Model operating at various flight speeds is studied for verification purpose, and the analysis and simulation results demonstrate the effectiveness of the proposed modeling approach.

  12. The 3.5 micron light curves of long period variable stars. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Strecker, D. W.

    1973-01-01

    Infrared observations at an effective wavelength of 3.5 microns of a selected group of long period variable (LPV) stars are presented. Mira type and semiregular stars of M, S, and C spectral classifications were monitored throughout the full cycle of variability. Although the variable infrared radiation does not exactly repeat in intensity or time, the regularity is sufficient to produce mean 3.5 micron light curves. The 3.5 micron maximum radiation lags the visual maximum by about one-seventh of a cycle, while the minimum 3.5 micron intensity occurs nearly one-half cycle after infrared maximum. In some stars, there are inflections or humps on the ascending portion of the 3.5 micron light curve which may also be seen in the visual variations.

  13. The L76V Drug Resistance Mutation Decreases the Dimer Stability and Rate of Autoprocessing of HIV-1 Protease by Reducing Internal Hydrophobic Contacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Louis, John M.; Zhang, Ying; Sayer, Jane M.

    2011-09-06

    The mature HIV-1 protease (PR) bearing the L76V drug resistance mutation (PR{sub L76V}) is significantly less stable, with a >7-fold higher dimer dissociation constant (K{sub d}) of 71 {+-} 24 nM and twice the sensitivity to urea denaturation (UC{sub 50} = 0.85 M) relative to those of PR. Differential scanning calorimetry showed decreases in T{sub m} of 12 C for PR{sub L76V} in the absence of inhibitors and 5-7 C in the presence of inhibitors darunavir (DRV), saquinavir (SQV), and lopinavir (LPV), relative to that of PR. Isothermal titration calorimetry gave a ligand dissociation constant of 0.8 nM for DRV,more » {approx}160-fold higher than that of PR, consistent with DRV resistance. Crystal structures of PR{sub L76V} in complexes with DRV and SQV were determined at resolutions of 1.45-1.46 {angstrom}. Compared to the corresponding PR complexes, the mutated Val76 lacks hydrophobic interactions with Asp30, Lys45, Ile47, and Thr74 and exhibits closer interactions with Val32 and Val56. The bound DRV lacks one hydrogen bond with the main chain of Asp30 in PR{sub L76V} relative to PR, possibly accounting for the resistance to DRV. SQV shows slightly improved polar interactions with PR{sub L76V} compared to those with PR. Although the L76V mutation significantly slows the N-terminal autoprocessing of the precursor TFR-PR{sub L76V} to give rise to the mature PR{sub L76V}, the coselected M46I mutation counteracts the effect by enhancing this rate but renders the TFR-PRM46I/L76V precursor less responsive to inhibition by 6 {micro}M LPV while preserving inhibition by SQV and DRV. The correlation of lowered stability, higher K{sub d}, and impaired autoprocessing with reduced internal hydrophobic contacts suggests a novel molecular mechanism for drug resistance.« less

  14. The All Sky Automated Survey. The Catalog of Variable Stars. II. 6^h-12^h Quarter of the Southern Hemisphere

    NASA Astrophysics Data System (ADS)

    Pojmanski, G.

    2003-12-01

    This paper describes the second part of the photometric data from the 9 arcdeg times 9 arcdeg ASAS camera monitoring the whole southern hemisphere in the V-band. Preliminary list of variable stars based on observations obtained since January 2001 is presented. Over 2800000 stars brighter than V=15 mag on 18000 frames were analyzed and 11357 were found to be variable (2685 eclipsing, 907 regularly pulsating, 521 Mira and 7244 other, mostly SR, IRR and LPV stars). Periodic light curves have been classified using the automated algorithm, which now takes into account IRAS infrared fluxes. Basic photometric properties are presented in the tables and some examples of thumbnail light curves are printed for reference. All photometric data are available over the INTERNET at http://www.astrouw.edu.pl/~gp/asas/asas.html or http://archive.princeton.edu/~asas.

  15. Onabotulinumtoxin A for treating overactive/poor compliant bladders in children and adolescents with neurogenic bladder secondary to myelomeningocele.

    PubMed

    Marte, Antonio

    2012-12-28

    This retrospective study was performed to verify the efficacy and safety of Onabotulinumtoxin A (BTX-A) in treating children with neurogenic bladder (NB) secondary to myelomeningocele (MMC) with detrusor overactivity/low compliance. From January 2002 to June 2011, 47 patients out of 68 with neuropathic bladder were selected (22 females, 25 males, age range 5-17 years; mean age 10.7 years at first injection). They presented overactive/poor compliant neurogenic bladders on clean intermittent catheterization, and were resistant or non compliant to pharmacological therapy. Ten patients presented second to fourth grade concomitant monolateral/bilateral vesicoureteral reflux (VUR). All patients were incontinent despite catheterization. In the majority of patients Botulinum-A toxin was administered under general/local anesthesia by the injection of 200 IU of toxin, without exceeding the dosage of 12 IU/kg body weight, diluted in 20 cc of saline solution in 20 sites, except in the periureteral areas. Follow-up included clinical and ultrasound examination, urodynamics performed at 6, 12 and 24 weeks, and annually thereafter. Seven patients remained stable, 21 patients required a second injection after 6-9 months and 19 a third injection. VUR was corrected, when necessary, in the same session after the BT-A injection, by 1-3 cc of subureteral Deflux®. Urodynamic parameters considered were leak point pressure (LPP), leak point volume (LPV) and specific volume at 20 cm H(2)O pressure. The results were analyzed using the Wilcoxon test. All patients experienced a significant 66.45% average increase of LPV (Wilcoxon paired rank test = 7169 × 10(-10)) and a significant 118.57% average increase of SC 20 (Wilcoxon paired rank test = 2.466 × 10(-12)). The difference between preoperative and postoperative LPP resulted not significant (Wilcoxon paired rank test = 0.8858) No patient presented severe systemic complications; 38/47 patients presented slight hematuria for 2-3 days. Two patients had postoperative urinary tract infection. All patients were hospitalized for 24 h with catheterization. Thirty-eight out of 47 patients achieved dryness between CIC; nine patients improved their incontinence but still need pads. Ten patients have resumed anticholinergic agents. Our results suggest that the use of BTX-A is safe and effective in patients with MMC with a positive effect on their dryness and quality of life.

  16. Onabotulinumtoxin A for Treating Overactive/Poor Compliant Bladders in Children and Adolescents with Neurogenic Bladder Secondary to Myelomeningocele

    PubMed Central

    Marte, Antonio

    2012-01-01

    This retrospective study was performed to verify the efficacy and safety of Onabotulinumtoxin A (BTX-A) in treating children with neurogenic bladder (NB) secondary to myelomeningocele (MMC) with detrusor overactivity/low compliance. From January 2002 to June 2011, 47 patients out of 68 with neuropathic bladder were selected (22 females, 25 males, age range 5–17 years; mean age 10.7 years at first injection). They presented overactive/poor compliant neurogenic bladders on clean intermittent catheterization, and were resistant or non compliant to pharmacological therapy. Ten patients presented second to fourth grade concomitant monolateral/bilateral vesicoureteral reflux (VUR). All patients were incontinent despite catheterization. In the majority of patients Botulinum-A toxin was administered under general/local anesthesia by the injection of 200 IU of toxin, without exceeding the dosage of 12IU/kg body weight, diluted in 20 cc of saline solution in 20 sites, except in the periureteral areas. Follow-up included clinical and ultrasound examination, urodynamics performed at 6, 12 and 24 weeks, and annually thereafter. Seven patients remained stable, 21 patients required a second injection after 6–9 months and 19 a third injection. VUR was corrected, when necessary, in the same session after the BT-A injection, by 1–3 cc of subureteral Deflux®. Urodynamic parameters considered were leak point pressure (LPP), leak point volume (LPV) and specific volume at 20 cm H2O pressure. The results were analyzed using the Wilcoxon test. All patients experienced a significant 66.45% average increase of LPV (Wilcoxon paired rank test = 7169 × 10 −10) and a significant 118.57% average increase of SC 20 (Wilcoxon paired rank test = 2.466 × 10 −12). The difference between preoperative and postoperative LPP resulted not significant (Wilcoxon paired rank test = 0.8858) No patient presented severe systemic complications; 38/47 patients presented slight hematuria for 2–3 days. Two patients had postoperative urinary tract infection. All patients were hospitalized for 24 h with catheterization. Thirty-eight out of 47 patients achieved dryness between CIC; nine patients improved their incontinence but still need pads. Ten patients have resumed anticholinergic agents. Our results suggest that the use of BTX-A is safe and effective in patients with MMC with a positive effect on their dryness and quality of life. PMID:23274271

  17. Non-contrast-enhanced MR portography with balanced steady-state free-precession sequence and time-spatial labeling inversion pulses: comparison of imaging with flow-in and flow-out methods.

    PubMed

    Furuta, Akihiro; Isoda, Hiroyoshi; Yamashita, Rikiya; Ohno, Tsuyoshi; Kawahara, Seiya; Shimizu, Hironori; Fujimoto, Koji; Kido, Aki; Kusahara, Hiroshi; Togashi, Kaori

    2014-09-01

    To compare and evaluate images of non-contrast-enhanced MR portography acquired with two different methods, the flow-in and flow-out methods. Twenty-five healthy volunteers were examined using respiratory-triggered three-dimensional balanced steady-state free-precession (SSFP) with two selective inversion recovery pulses (flow-in method) and one tagging pulse and one nonselective inversion recovery pulse (flow-out method). For quantitative analysis, vessel-to-liver contrast (Cv-l) ratios of the main portal vein (MPV), right portal vein (RPV), and left portal vein (LPV) were measured. The quality of portal vein visualization was scored using a four-point scale. The Cv-ls of the MPV, RPV, and LPV were all significantly higher with the flow-out than flow-in method (MPV = 0.834 ± 0.06 versus 0.711 ± 0.10; RPV = 0.861 ± 0.04 versus 0.729 ± 0.11; LPV = 0.786 ± 0.08 versus 0.545 ± 0.22; P < 0.0001). In all analyses of vessel visibility, non-contrast-enhanced MR portography with the flow-out method showed higher scores than with the flow-in method. With the flow-out method, visual scores of the MPV, RPV, portal vein branches of segments 4 (P4), and 8 (P8) were significantly better than with the flow-in method (MPV = 3.4 ± 0.7 versus 2.6 ± 0.9; RPV = 4.0 ± 0.0 versus 3.5 ± 0.9; P4 = 2.8 ± 1.3 versus 1.6 ± 1.0; P8 = 4.0 ± 0.0 versus 2.9 ± 1.1; P < 0.05). Non-contrast-enhanced MR portography with the flow-out method improves the visualization of the intrahepatic portal vein in comparison with the flow-in method. J. Magn. Reson. Imaging 2014;40:583-587. © 2013 Wiley Periodicals, Inc. © 2013 Wiley Periodicals, Inc.

  18. Adverse events and adherence to HIV post-exposure prophylaxis: a cohort study at the Korle-Bu Teaching Hospital in Accra, Ghana.

    PubMed

    Tetteh, Raymond A; Nartey, Edmund T; Lartey, Margaret; Mantel-Teeuwisse, Aukje K; Leufkens, Hubert G M; Nortey, Priscilla A; Dodoo, Alexander N O

    2015-06-20

    There is strong evidence that post-exposure prophylaxis (PEP) with antiretroviral drugs in the timely management of occupational exposures sustained by healthcare workers decreases the risk of HIV infection and PEP is now widely used. Antiretroviral drugs have well documented toxicities and produce adverse events in patients living with HIV/AIDS. In the era of "highly active antiretroviral therapy", non-adherence to treatment has been closely linked to the occurrence of adverse events in HIV patients and this ultimately influences treatment success but the influence of adverse events on adherence during PEP is less well studied. Following the introduction of a HIV post-exposure prophylaxis program in the Korle-Bu Teaching Hospital in January 2005, the incidence of adverse events and adherence were documented in occupationally-exposed healthcare workers (HCWs) and healthcare students (HCSs). Cohort event monitoring was used in following-up on exposed HCWs/HCSs for the two study outcomes; adverse events and adherence. All adverse events reported were grouped by MedDRA system organ classification and then by preferred term according to prophylaxis regimen. Adherence was determined by the completion of prophylaxis schedule. Cox proportional regression analysis was applied to determine the factors associated with the cohort study outcomes. Differences in frequencies were tested using the Chi square test and p < 0.05 was considered statistically significant. A total of 228 exposed HCWs/HCSs were followed up during the study, made up of 101 exposed HCWs/HCSs administered lamivudine/zidovudine (3TC/AZT) for 3 days; 75 exposed HCWs/HCSs administered lamivudine/zidovudine (3TC/AZT) for 28 days; and 52 exposed HCWs/HCSs administered lamivudine/zidovudine/lopinavir-ritonavir (3TC/AZT/LPV-RTV) for 28 days. The frequency of adverse events was 28% (n = 28) in exposed HCWs/HCSs administered 3TC/AZT for 3 days, 91% (n = 68) in exposed HCWs/HCSs administered 3TC/AZT for 28 days and 96% (n = 50) in exposed HCWs/HCSs administered 3TC/AZT/LPV-RTV for 28 days. Nausea was the most commonly reported adverse events in all three regimens. Adherence was complete in all exposed HCWs/HCSs administered 3TC/AZT for 3days, 56% (n = 42) in exposed HCWs/HCSs administered 3TC/AZT for 28 days and 62% (n = 32) in exposed HCWs/HCSs administered 3TC/AZT/LPV-RTV for 28 days. In the Cox regression multi-variate analysis, exposed HCWs/HCSs administered 3TC/AZT for 3 days were 70% less likely to report adverse events compared with exposed HCWs/HCSs administered 3TC/AZT for 28 days (Adjusted HR = 0.30 [95% CI, 0.18-0.48], p < 0.001). Exposed HCWs/HCSs administered 3TC/AZT for 3 days were 75% more likely to adhere to the schedule compared with exposed HCWs/HCSs administered 3TC/AZT for 28 days (Adjusted HR = 1.75 [95% CI, 1.16-2.66], p = 0.008). The intolerance to adverse events was cited as the sole reason for truncating PEP, thereby indicating the need for adequate, appropriate and effective counselling, education, active follow-up (possibly through mobile /phone contact) and management of adverse events. Education on the need to complete PEP schedule (especially for exposed HCWs/HCSs on 28-day schedule) can lead to increased adherence, which is very critical in minimizing the risk of HIV sero-conversion. The present results also indicate that cohort event monitoring could be an effective pharmacovigilance tool in monitoring adverse events in exposed HCWs/HCSs on HIV post-exposure prophylaxis.

  19. Advanced receiver autonomous integrity monitoring using triple frequency data with a focus on treatment of biases

    NASA Astrophysics Data System (ADS)

    El-Mowafy, Ahmed

    2017-04-01

    Most current Advanced Receiver Autonomous Integrity Monitoring (ARAIM) methods are designed to use dual-frequency ionosphere-free observations. These methods assume that receiver bias is absorbed in the common receiver clock offset and bound satellite biases by nominal values. However, most multi-constellation Global Navigation Satellite Systems (GNSS) can offer triple frequency data that can be used for civilian applications in the future, which can improve observation redundancy, solution precision and detection of faults. In this contribution, we explore the use of this type of observations from GPS, Galileo and BeiDou in ARAIM. Nevertheless, the use of triple frequency data introduces receiver differential biases that have to be taken into consideration. To demonstrate the significance of these additional biases we first present a method to quantify them at stations of known coordinates and using available products from the International GNSS service (IGS). To deal with the additional receiver biases, we use a between-satellite single difference (BSSD) observation model that eliminates their effect. A pilot test was performed to evaluate ARAIM availability for Localizer Performance with Vertical guidance down to 200 feet (LPV-200) when using the triple-frequency observations. Real data were collected for one month at stations of known coordinates located in regions of different satellite coverage characteristics. The BSSD triple-frequency model was evaluated to give early indication about its feasibility, where the implementation phase still requires further comprehensive studies. The vertical position error was always found to be bounded by the protection level proven initial validity of the proposed integrity model.

  20. Evaluating nanoscale ultra-thin metal films by means of lateral photovoltaic effect in metal-semiconductor structure.

    PubMed

    Zheng, Diyuan; Yu, Chongqi; Zhang, Qian; Wang, Hui

    2017-12-15

    Nanoscale metal-semiconductor (MS) structure materials occupy an important position in semiconductor and microelectronic field due to their abundant physical phenomena and effects. The thickness of metal films is a critical factor in determining characteristics of MS devices. How to detect or evaluate the metal thickness is always a key issue for realizing high performance MS devices. In this work, we propose a direct surface detection by use of the lateral photovoltaic effect (LPE) in MS structure, which can not only measure nanoscale thickness, but also detect the fluctuation of metal films. This method is based on the fact that the output of lateral photovoltaic voltage (LPV) is closely linked with the metal thickness at the laser spot. We believe this laser-based contact-free detection is a useful supplement to the traditional methods, such as AFM, SEM, TEM or step profiler. This is because these traditional methods are always incapable of directly detecting ultra-thin metal films in MS structure materials.

  1. Evaluating nanoscale ultra-thin metal films by means of lateral photovoltaic effect in metal-semiconductor structure

    NASA Astrophysics Data System (ADS)

    Zheng, Diyuan; Yu, Chongqi; Zhang, Qian; Wang, Hui

    2017-12-01

    Nanoscale metal-semiconductor (MS) structure materials occupy an important position in semiconductor and microelectronic field due to their abundant physical phenomena and effects. The thickness of metal films is a critical factor in determining characteristics of MS devices. How to detect or evaluate the metal thickness is always a key issue for realizing high performance MS devices. In this work, we propose a direct surface detection by use of the lateral photovoltaic effect (LPE) in MS structure, which can not only measure nanoscale thickness, but also detect the fluctuation of metal films. This method is based on the fact that the output of lateral photovoltaic voltage (LPV) is closely linked with the metal thickness at the laser spot. We believe this laser-based contact-free detection is a useful supplement to the traditional methods, such as AFM, SEM, TEM or step profiler. This is because these traditional methods are always incapable of directly detecting ultra-thin metal films in MS structure materials.

  2. Viirs Land Science Investigator-Led Processing System

    NASA Astrophysics Data System (ADS)

    Devadiga, S.; Mauoka, E.; Roman, M. O.; Wolfe, R. E.; Kalb, V.; Davidson, C. C.; Ye, G.

    2015-12-01

    The objective of the NASA's Suomi National Polar Orbiting Partnership (S-NPP) Land Science Investigator-led Processing System (Land SIPS), housed at the NASA Goddard Space Flight Center (GSFC), is to produce high quality land products from the Visible Infrared Imaging Radiometer Suite (VIIRS) to extend the Earth System Data Records (ESDRs) developed from NASA's heritage Earth Observing System (EOS) Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the EOS Terra and Aqua satellites. In this paper we will present the functional description and capabilities of the S-NPP Land SIPS, including system development phases and production schedules, timeline for processing, and delivery of land science products based on coordination with the S-NPP Land science team members. The Land SIPS processing stream is expected to be operational by December 2016, generating land products either using the NASA science team delivered algorithms, or the "best-of" science algorithms currently in operation at NASA's Land Product Evaluation and Algorithm Testing Element (PEATE). In addition to generating the standard land science products through processing of the NASA's VIIRS Level 0 data record, the Land SIPS processing system is also used to produce a suite of near-real time products for NASA's application community. Land SIPS will also deliver the standard products, ancillary data sets, software and supporting documentation (ATBDs) to the assigned Distributed Active Archive Centers (DAACs) for archival and distribution. Quality assessment and validation will be an integral part of the Land SIPS processing system; the former being performed at Land Data Operational Product Evaluation (LDOPE) facility, while the latter under the auspices of the CEOS Working Group on Calibration & Validation (WGCV) Land Product Validation (LPV) Subgroup; adopting the best-practices and tools used to assess the quality of heritage EOS-MODIS products generated at the MODIS Adaptive Processing System (MODAPS).

  3. Global identification of stochastic dynamical systems under different pseudo-static operating conditions: The functionally pooled ARMAX case

    NASA Astrophysics Data System (ADS)

    Sakellariou, J. S.; Fassois, S. D.

    2017-01-01

    The identification of a single global model for a stochastic dynamical system operating under various conditions is considered. Each operating condition is assumed to have a pseudo-static effect on the dynamics and be characterized by a single measurable scheduling variable. Identification is accomplished within a recently introduced Functionally Pooled (FP) framework, which offers a number of advantages over Linear Parameter Varying (LPV) identification techniques. The focus of the work is on the extension of the framework to include the important FP-ARMAX model case. Compared to their simpler FP-ARX counterparts, FP-ARMAX models are much more general and offer improved flexibility in describing various types of stochastic noise, but at the same time lead to a more complicated, non-quadratic, estimation problem. Prediction Error (PE), Maximum Likelihood (ML), and multi-stage estimation methods are postulated, and the PE estimator optimality, in terms of consistency and asymptotic efficiency, is analytically established. The postulated estimators are numerically assessed via Monte Carlo experiments, while the effectiveness of the approach and its superiority over its FP-ARX counterpart are demonstrated via an application case study pertaining to simulated railway vehicle suspension dynamics under various mass loading conditions.

  4. Antiretroviral Treatment in HIV-1-Positive Mothers: Neurological Implications in Virus-Free Children

    PubMed Central

    Coelho, Antonio Victor Campos; Tricarico, Paola Maura; Celsi, Fulvio; Crovella, Sergio

    2017-01-01

    Since the worldwide introduction of antiretroviral therapy (ART) in human immunodeficiency virus type 1, HIV-1-positive mothers, together with HIV-1 testing prior to pregnancy, caesarian birth and breastfeeding cessation with replacement feeding, a reduction of HIV-1 mother-to-child transmission (MTCT) has been observed in the last few years. As such, an increasing number of children are being exposed in utero to ART. Several questions have arisen concerning the neurological effects of ART exposure in utero, considering the potential effect of antiretroviral drugs on the central nervous system, a structure which is in continuous development in the fetus and characterized by great plasticity. This review aims at discussing the possible neurological impairment of children exposed to ART in utero, focusing attention on the drugs commonly used for HIV-1 MTCT prevention, clinical reports of ART neurotoxicity in children born to HIV-1-positive mothers, and neurologic effects of protease inhibitors (PIs), especially ritonavir-“boosted” lopinavir (LPV/r) in cell and animal central nervous system models evaluating the potential neurotoxic effect of ART. Finally, we present the findings of a meta-analysis to assess the effects on the neurodevelopment of children exposed to ART in utero. PMID:28212307

  5. Effect of changing from first- to second-line antiretroviral therapy on renal function: a retrospective study based on data from a single health facility in Namibia.

    PubMed

    Kalemeera, Francis; Mbango, Christofina; Mubita, Mwangana; Naikaku, Esther; Gaida, Razia; Godman, Brian

    2016-08-01

    Tenofovir disoproxil fumarate (TDF) and lopinavir/ritonavir (LPV/r) can cause renal impairment with this combination co-administered during second-line combination antiretroviral therapy (cART) potentially associated with greater risk of nephrotoxicity. As a result, the aim of this study is to assess effects of second-line cART on renal function. Retrospective longitudinal study in patients receiving cART. 71 patients received TDF, zidovudine or stavudine, each combined with 3TC/NVP or 3TC/EFV. Before second-line cART, 46.5% had abnormal kidney function. First-line cART had no relationship with calculated creatinine clearance (CrCl). During second-line cART, more males than females had abnormal renal function and more females experienced increases in CrCl. Calculated CrCl during second-line cART related strongly with CrCl during first-line cART. Time spent on cART had a weak relationship with CrCl. Patients on first-line cART for several years without renal impairment may experience new onset impairment during second line cART. Patients with pre-existing renal impairment just before switching to second-line cART may experience a further decline.

  6. Clinical and laboratorial impact of antiretroviral therapy in a cohort of Portuguese patients chronically infected with HIV-2.

    PubMed

    Miranda, Ana; Peres, Susana; Moneti, Virginia; Azevedo, Telma; Aldir, Isabel; Mansinho, Kamal

    2014-01-01

    HIV-2 infection is endemic in West Africa and some European countries, namely Portugal. HIV-2 antiretroviral (ARV) treatment presents some restrains related to intrinsic resistance to non-nucleoside reverse transcriptase inhibitors (NNRTI) and fusion inhibitors, and poorer response to protease inhibitors (PI). Retrospective observational study of a cohort of 135 infected HIV-2 patients, diagnosed between 1989 and 2008. Evaluation of epidemiologic, clinical, immunologic and virologic progression, comparing to groups of patients (naïve vs ARV experienced); characterization of therapeutic, immunologic and virologic response. SPSS version 20.0 was used for statistical analysis. The study included 135 patients: 41% (n=55) naïve and 59% (n=80) with ARV experience. The comparison between groups (naïve vs ARV) revealed: male prevalence 76% vs 50%; mean age 54.5 years vs 54.8 (p=0.90); main geographic origin Guiné Bissau (47% vs 44%) and Portugal (22% vs 33%); and transmission mainly acquired by heterosexual contact (87% vs 80%). Mean time since diagnosis was 14 vs 13 years (p=0.31); 2% vs 50% presented AIDS criteria at diagnosis (p<0.001) and 93% vs 38% registered TCD4>350 cell/mm(3) at diagnosis (p<0.001). Immunological evolution showed no significant decline in naïve population (Δ=-67 cell/mm(3) - p=0.18) and a significant recovery in ARV experienced (Δ=+207 cell/mm(3) - p<0.001). Global mortality rate found was 18% (6% vs 13% - p=0.122). Eighty patients initiated ARV: 84% presented a time interval of ARV exposure between 0-5 years (42%) and 5-10 years (42%). Fifty percent experienced ≤2 ARV regimens and the remaining >2 regimes. Considering the first ARV therapy: 56% initiated PI, 30% NTRI and 5% integrase inhibitor (II)-based regimens. Currently, 54 patients maintain regular follow-up and ARV therapy: 60% NTRI+PI; 37% NRTI+PI+II and 3% NRTI+II. TDF/FTC is the backbone in 56%. Most frequent PIs are LPV/r (54%), DRV/r (19%) and ATV/r (12%). Mean time of exposure to NRTI=3 years, PI=7 years and II=2 years. Immunologic recovery was sustained for each of the ARV class considered (NRTI Δ=+144 cell/mm(3); PI=Δ+92 cell/mm(3); II=Δ=+116 cell/mm(3)). This is a cohort accompanied for a long period and the majority of patients present extensive ARV experience. The ARV-experienced patients registered a favourable response to treatment, with sustained immune recovery (Δ=+207 cell/mm(3)) and virologic control in 74%. Immunologic behaviour evidenced a sustained gain for each of the ARV class considered.

  7. Combined Rex-bypass shunt with pericardial devascularization alleviated prehepatic portal hypertension caused by cavernomatous transformation of portal vein.

    PubMed

    Wang, Ruo-Yi; Wang, Jun-Feng; Liu, Qian; Ma, Nan; Chen, Wei-Xiu; Li, Jin-Liang

    2017-09-01

    To evaluate the effects of combined Rex-bypass shunt and pericardial devascularization on prehepatic portal hypertension secondary to cavernomatous transformation of portal vein (CTPV). Forty-two patients aged from 3 years to 49 years (divided into 3 groups), 26 cases male and 16 female, with prehepatic vascular hepertention were treated with Rex-bypass shunt combined with pericardial devascularization. In each patient, preoperative assessment included ultrasound and computed tomographic angiography of the portal vein and blood analysis. The procedure was Rex-bypass shunt (with or without graft), and patients with moderate or severe gastroesophageal varices required additional paraesophagogastric devascularization. Splenectomy or subtotal splenectomy was performed if combined hypersplenism co-existed. All data were analyzed retrospectively. No intraoperative death occurred, blood routine analysis improved (P < 0.05), the blood flow velocity (P < 0.05) and diameter (P < 0.05) of the left portal vein (LPV) significantly increased, the esophageal and gastric varices significantly relieved in 34 patients (P < 0.05), and better effects of earlier operations were demonstrated than the delayed ones (P < 0.05). During the period of follow-up from 6 to 64 months, the overall patency rate was 85.7% and the younger the age the better of the effect. Rex-bypass shunt combined with pericardial devascularization is a safe and effective procedure for prehepatic portal hypertension caused by CTPV.

  8. Time-resolved FUSE photometric and spectroscopic observations: PG 1219+534, PG 1605+072, and PG 1613+426

    NASA Astrophysics Data System (ADS)

    Kuassivi; Bonanno, A.; Ferlet, R.

    2005-11-01

    We report the detection of pulsations in the far ultraviolet (FUV) light curves of PG 1219+534, PG 1605+072 and PG 1613+426 obtained with the Far Ultraviolet Spectroscopic Explorer (FUSE) in time tagged mode (TTAG). Exposures of the order of a few ksec were sufficient to observe the main frequencies of PG 1219+534 and PG 1605+072 and confirm the detection of a pulsation mode at the surface of PG 1613+426 as reported from ground. For the first time we derive time resolved spectroscopic FUSE data of a sdB pulsator (PG 1605+072) and comment on its line profile variation diagram (lpv diagram). We observe the phase shift between the maximum luminosity and the maximum radius to be consistent with the model of an adiabatic pulsator. We also present evidence that the line broadening previously reported is not caused by rotation but is rather an observational bias due to the rapid Doppler shift of the lines with 17 km s-1 amplitude. Thus our observations do not support the previous claim that PG 1605+072 is (or will evolve into) an unusually fast rotating degenerate dwarf. These results demonstrate the asteroseismological potential of the FUSE satellite which should be viewed as another powerful means of investigating stellar pulsations, along with the MOST and COROT missions.

  9. Ultrasensitive HIV-1 Viral Load as a Marker of Treatment Choice for Simplification Strategies.

    PubMed

    Lambert-Niclot, Sidonie; Grude, Maxime; Meynard, Jean-Luc; Marcelin, Anne-Geneviève; Valantin, Marc-Antoine; Flandre, Philippe; Izopet, Jacques; Moinot, Laetitia; Bouteloup, Vincent; Calvez, Vincent; Katlama, Christine; Girard, Pierre-Marie; Morand-Joubert, Laurence

    2018-05-15

    We pooled the results of three randomized trials that compared the efficacy of PI/r monotherapy and standard triple therapy as maintenance therapy and evaluated: 1) the distribution of ultrasensitive viral load (USVL) at week 96 (W96), 2) factors associated with virological success (VL<50 copy/mL) at W96, and 3) factors associated with USVL<1 copy/ml (c/ml) at W96. Virological failure was defined as two consecutive measurements of HIV-1 RNA viral load >50 copies/mL and was analyzed in intention-to-treat. USVL was measured with commercial standard Roche assay. A logistic model was used to investigate which variables were predictive of VF. The Fisher exact test was used to investigate differences in USVL at W96. Among 609 patients, 73% were male with a median age of 44.4 years (IQR 39.8-52.1), the treatment duration was four years, (2.4-7.6), baseline CD4/CD8 ratio 0.8 (0.6-1.10), baseline CD4 cell count 564/mm3 (422-707), and 59% presented a baseline USVL<1 copy/mL. At W96, the proportion of USVL<1 copy/mL was significantly lower for PI/r monotherapy than triple therapy (65% versus 74%; p=0.04). Overall, baseline USVL<1 copy/mL, triple therapy, and being female were associated with an USVL<1 copy/mL at W96 (p<0.0001, p=0.049 and p=0.006). For PI/r monotherapy, receiving DRV/r rather than LPV/r was associated with an USVL<1 copy/mL at W96 (p=0.03). Factors associated with virological success at W96 were higher baseline CD4 cell count (p=0.034) and baseline USVL<1 copy/mL (p=0.0005). Although PI/r monotherapy is not widely recommended, this strategy is still sometimes used and USVL determination for virologically-controlled patients may help to select the best candidates for PI/r monotherapy.

  10. Conception de lois de pilotage robustes et sequencement de gains par l'approche de systemes lineaires a parametres variants

    NASA Astrophysics Data System (ADS)

    Hentabli, Kamel

    Cette recherche s'inscrit dans le cadre du projet de recherche Active Control Technology entre l'Ecole de Technologie Superieure et le constructeur Bombardier Aeronautique . Le but est de concevoir des strategies de commandes multivariables et robustes pour des modeles dynamiques d'avions. Ces strategies de commandes devraient assurer a l'avion une haute performance et satisfaire des qualites de vol desirees en l'occurrence, une bonne manoeuvrabilite, de bonnes marges de stabilite et un amortissement des mouvements phugoides et rapides de l'avion. Dans un premier temps, nous nous sommes principalement interesses aux methodes de synthese LTI et plus exactement a l'approche Hinfinity et la mu-synthese. Par la suite, nous avons accorde un interet particulier aux techniques de commande LPV. Pour mener a bien ce travail, nous avons envisage une approche frequentielle, typiquement Hinfinity. Cette approche est particulierement interessante, dans la mesure ou le modele de synthese est construit directement a partir des differentes specifications du cahier des charges. En effet, ces specifications sont traduites sous forme de gabarits frequentiels, correspondant a des ponderations en entree et en sortie que l'on retrouve dans la synthese Hinfinity classique. Par ailleurs, nous avons utilise une representation de type lineaire fractionnelle (LFT), jugee mieux adaptee pour la prise en compte des differents types d'incertitudes, qui peuvent intervenir sur le systeme. De plus, cette representation s'avere tres appropriee pour l'analyse de la robustesse via les outils de la mu-analyse. D'autre part, afin d'optimiser le compromis entre les specifications de robustesse et de performance, nous avons opte pour une structure de commande a 2 degres de liberte avec modele de reference. Enfin, ces techniques sont illustrees sur des applications realistes, demontrant ainsi la pertinence et l'applicabilite de chacune d'elle. Mots cles. Commande de vol, qualites de vol et manoeuvrabilite, commande robuste, approche Hinfinity , mu-synthese, systemes lineaires a parametres variants, sequencement de gains, transformation lineaire fractionnelle, inegalite matricielle lineaire.

  11. Prototypical Recombinant Multi-Protease-Inhibitor-Resistant Infectious Molecular Clones of Human Immunodeficiency Virus Type 1

    PubMed Central

    Varghese, Vici; Mitsuya, Yumi; Fessel, W. Jeffrey; Liu, Tommy F.; Melikian, George L.; Katzenstein, David A.; Schiffer, Celia A.; Holmes, Susan P.

    2013-01-01

    The many genetic manifestations of HIV-1 protease inhibitor (PI) resistance present challenges to research into the mechanisms of PI resistance and the assessment of new PIs. To address these challenges, we created a panel of recombinant multi-PI-resistant infectious molecular clones designed to represent the spectrum of clinically relevant multi-PI-resistant viruses. To assess the representativeness of this panel, we examined the sequences of the panel's viruses in the context of a correlation network of PI resistance amino acid substitutions in sequences from more than 10,000 patients. The panel of recombinant infectious molecular clones comprised 29 of 41 study-defined PI resistance amino acid substitutions and 23 of the 27 tightest amino acid substitution clusters. Based on their phenotypic properties, the clones were classified into four groups with increasing cross-resistance to the PIs most commonly used for salvage therapy: lopinavir (LPV), tipranavir (TPV), and darunavir (DRV). The panel of recombinant infectious molecular clones has been made available without restriction through the NIH AIDS Research and Reference Reagent Program. The public availability of the panel makes it possible to compare the inhibitory activities of different PIs with one another. The diversity of the panel and the high-level PI resistance of its clones suggest that investigational PIs active against the clones in this panel will retain antiviral activity against most if not all clinically relevant PI-resistant viruses. PMID:23796938

  12. National and international organization of phenology as a tool for science, management and education in a changing environment

    NASA Astrophysics Data System (ADS)

    Weltzin, J. F.; National Coordinating Office Of Usa National Phenology Network

    2010-12-01

    Patterns of phenology for plants and animals control ecosystem processes, determine land surface properties, control biosphere-atmosphere interactions, and affect food production, health, conservation, and recreation. The USA National Phenology Network (USA-NPN; www.usanpn.org), established in 2007, is a national science and monitoring initiative focused on phenology as a tool to understand how plants, animals and landscapes respond to climatic variability and change. Core functions of the National Coordinating Office (NCO) of USA-NPN are to provide a national information management system including databases, develop and implement internationally standardized phenology monitoring protocols, create partnerships for implementation, facilitate research and the development of decision support tools, and promote education and outreach activities related to phenology and climate change. USA-NPN has a number of new tools to facilitate science, management and education related to phenology at local, regional and national scales. The information management system includes an advanced on-line user interface to facilitate entry and download of contemporary organismal phenology data into the National Phenology Database, access to important historic phenology datasets, and a metadata editor for description, registration and search of phenology datasets. An integrated animal and plant phenology monitoring program provides internationally standardized methods and monitoring protocols for over 400 animal and plant species, with additional species added upon demand. Monitoring methods are designed to facilitate collection of sampling intensity and absence data for both plants and animals, and the interface enables the capture of considerable metadata (at granularities including observer, site, organism, and observation). National scale, in-situ observations since 2009 are now available for land product parameterization and validation, and USA-NPN is participating in the Committee on Earth Observation Satellites (CEOS) Land Product Validation (LPV) Phenology Focus Group. Partnerships with a variety of other organizations benefit from recent development and distribution of standard operating procedures (SOPs) and web services with data input and output functions. USA-NPN facilitates research and the development of decision support tools through provision of communication, coordination and collaboration in a data-rich environment. Education and outreach are facilitated by new on-line training materials, in-person and distance workshops, and a strategic education plan in development. Finally, USA-NPN is collaborating with other national phenology networks around the globe to create an international community of practice for phenology within the collaborative infrastructure created by Group on Earth Observations (GEO).

  13. Studies of the Long Secondary Periods in Pulsating Red Giants. II. Lower-Luminosity Stars

    NASA Astrophysics Data System (ADS)

    Percy, J. R.; Leung, H. W.

    2017-06-01

    We have used AAVSO visual and photoelectric V data, and the AAVSO time-series package VSTAR and the Lomb-Scargle time-series algorithm to determine improved pulsation periods, "long secondary periods" (LSPs), and their amplitudes in 51 shorter-period pulsating red giants in the AAVSO photoelectric photometry program, and in the AAVSO long-period variable (LPV) binocular program. As is well known, radial pulsation becomes detectable in red giants at about spectral type M0, with periods of about 20 days. We find that the LSP phenomenon is also first detectable at about M0. Pulsation and LSP amplitudes increase from near zero to about 0.1 at pulsation periods of 100 days. At longer periods, the pulsation amplitudes continue to increase, but the LSP amplitudes are generally between 0.1 and 0.2 on average. The ratios of LSP to pulsation period cluster around 5 and 10, presumably depending on whether the pulsation period is the fundamental or first overtone. The pulsation and LSP phase curves are generally close to sinusoidal, except when the amplitude is small, in which case they may be distorted by observational scatter or, in the case of the LSP amplitude, by the pulsational variability. As with longer-period stars, the LSP amplitude i ncreases and decreases by a factor of two or more, for unknown reasons, on a time scale of about 20 LSPs. The LSP phenomenon is thus present and similar in radially pulsating red giants of all periods. Its cause remains unknown.

  14. Current Source Based on H-Bridge Inverter with Output LCL Filter

    NASA Astrophysics Data System (ADS)

    Blahnik, Vojtech; Talla, Jakub; Peroutka, Zdenek

    2015-09-01

    The paper deals with a control of current source with an LCL output filter. The controlled current source is realized as a single-phase inverter and output LCL filter provides low ripple of output current. However, systems incorporating LCL filters require more complex control strategies and there are several interesting approaches to the control of this type of converter. This paper presents the inverter control algorithm, which combines model based control with a direct current control based on resonant controllers and single-phase vector control. The primary goal is to reduce the current ripple and distortion under required limits and provides fast and precise control of output current. The proposed control technique is verified by measurements on the laboratory model.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fernandez-Gutierrez, Sulmer, E-mail: sulmer.a.fernandez.gutierrez@intel.com; Browning, Jim; Lin, Ming-Chieh

    Phase-control of a magnetron is studied via simulation using a combination of a continuous current source and a modulated current source. The addressable, modulated current source is turned ON and OFF at the magnetron operating frequency in order to control the electron injection and the spoke phase. Prior simulation work using a 2D model of a Rising Sun magnetron showed that the use of 100% modulated current controlled the magnetron phase and allowed for dynamic phase control. In this work, the minimum fraction of modulated current source needed to achieve a phase control is studied. The current fractions (modulated versusmore » continuous) were varied from 10% modulated current to 100% modulated current to study the effects on phase control. Dynamic phase-control, stability, and start up time of the device were studied for all these cases showing that with 10% modulated current and 90% continuous current, a phase shift of 180° can be achieved demonstrating dynamic phase control.« less

  16. An Improved Model Predictive Current Controller of Switched Reluctance Machines Using Time-Multiplexed Current Sensor

    PubMed Central

    Li, Bingchu; Ling, Xiao; Huang, Yixiang; Gong, Liang; Liu, Chengliang

    2017-01-01

    This paper presents a fixed-switching-frequency model predictive current controller using multiplexed current sensor for switched reluctance machine (SRM) drives. The converter was modified to distinguish currents from simultaneously excited phases during the sampling period. The only current sensor installed in the converter was time division multiplexing for phase current sampling. During the commutation stage, the control steps of adjacent phases were shifted so that sampling time was staggered. The maximum and minimum duty ratio of pulse width modulation (PWM) was limited to keep enough sampling time for analog-to-digital (A/D) conversion. Current sensor multiplexing was realized without complex adjustment of either driver circuit nor control algorithms, while it helps to reduce the cost and errors introduced in current sampling due to inconsistency between sensors. The proposed controller is validated by both simulation and experimental results with a 1.5 kW three-phase 12/8 SRM. Satisfied current sampling is received with little difference compared with independent phase current sensors for each phase. The proposed controller tracks the reference current profile as accurately as the model predictive current controller with independent phase current sensors, while having minor tracking errors compared with a hysteresis current controller. PMID:28513554

  17. Control Strategy of Active Power Filter Based on Modular Multilevel Converter

    NASA Astrophysics Data System (ADS)

    Xie, Xifeng

    2018-03-01

    To improve the capacity, pressure resistance and the equivalent switching frequency of active power filter (APF), a control strategy of APF based on Modular Multilevel Converter (MMC) is presented. In this Control Strategy, the indirect current control method is used to achieve active current and reactive current decoupling control; Voltage Balance Control Strategy is to stabilize sub-module capacitor voltage, the predictive current control method is used to Track and control of harmonic currents. As a result, the harmonic current is restrained, and power quality is improved. Finally, the simulation model of active power filter controller based on MMC is established in Matlab/Simulink, the simulation proves that the proposed strategy is feasible and correct.

  18. Current control of PMSM based on maximum torque control reference frame

    NASA Astrophysics Data System (ADS)

    Ohnuma, Takumi

    2017-07-01

    This study presents a new method of current controls of PMSMs (Permanent Magnet Synchronous Motors) based on a maximum torque control reference frame, which is suitable for high-performance controls of the PMSMs. As the issues of environment and energy increase seriously, PMSMs, one of the AC motors, are becoming popular because of their high-efficiency and high-torque density in various applications, such as electric vehicles, trains, industrial machines, and home appliances. To use the PMSMs efficiently, a proper current control of the PMSMs is necessary. In general, a rotational coordinate system synchronizing with the rotor is used for the current control of PMSMs. In the rotating reference frame, the current control is easier because the currents on the rotating reference frame can be expressed as a direct current in the controller. On the other hand, the torque characteristics of PMSMs are non-linear and complex; the PMSMs are efficient and high-density though. Therefore, a complicated control system is required to involve the relation between the torque and the current, even though the rotating reference frame is adopted. The maximum torque control reference frame provides a simpler way to control efficiently the currents taking the torque characteristics of the PMSMs into consideration.

  19. High Virologic Failure Rates with Maraviroc-Based Salvage Regimens Among Indian Patients: A Preliminary Analysis-Maraviroc Effectiveness in HIV-1 Subtype C.

    PubMed

    Pujari, Sanjay; Gaikwad, Sunil; Bele, Vivek; Joshi, Kedar; Dabhade, Digamber

    2018-01-01

    There is no information on the clinical effectiveness of Maraviroc (MVC) amongst People Living with HIV (PLHIV) in India infected with HIV-1 Subtype C viruses. We conducted a retrospective chart review of adult PLHIV on MVC based Antiretroviral (ARV) regimens for at least 6 months. Maraviroc was initiated amongst PLHIV with documented R5 tropic viruses (determined by in-house population sequencing of the V3 loop in triplicate and interpreted using the Geno2Pheno algorithm) in combination with an Optimized Background regimen (designed using genotypic resistance testing and past ARV history). Plasma viral loads (PVL) are performed 6 months post-initiation and annually thereafter. Primary outcome d. Median duration on MVC treatment was 1.8 years (range 1-2.9 years) while median duration of ART prior to switching to MVC was 13 years. Maraviroc was combined with Darunavir/ritonavir (DRV/r) (n=10), Atazanavir/r (ATV/r) (n=2) and Lopinavir/r (LPV/r) (n=1). All PLHIV were infected with HIV-1 Subtype C. Only 23.3% PLHIV achieved virologic suppression at 6 months and sustained it for 2.3 years. Median CD4 count change from baseline was +117 (n=13), +228 (n=10), +253 (n=9), and +331 (n=4) at 6, 12, 18 and 24 months respectively. Repeat tropism among patients with virologic failure demonstrated R5 virus. High rates of virologic failure was seen when MVC was used amongst treatment experienced PLHIV infected with HIV-1 Subtype C in India. was the proportion of PLHIV with virologic success (PVL<50 copies/ml) at last follow up visit. Data on 13 PLHIV were analyze.

  20. Adherence to Anti-Retroviral Therapy in North Central Nigeria.

    PubMed

    Avong, Yohanna Kambai; van Wyk, Brian; Njab, Jean; Abimiku, Alash'le G; Ndembi, Nicaise; Okuma, James; Ogbanufe, Obinna; Ekong, Ernest; Dakum, Patrick; Blattner, William A

    2015-01-01

    Nigeria bears nearly 10% of the global burden of HIV/AIDS. Most of the AIDS patients dwell in the part of Nigeria known as the "North Central" geopolitical region. Sustaining HIV patients in this high risk region is critical for the overall success of the ART program in Nigeria. We assessed the level of adherence to ART and adherence determinants among participants who had been on ART for an average of three and half years. Eligible study participants initiated HAART between 2004 and 2010. HAART regimens contained AZT/3TC +NVP or EFV; AZT/3TC/NVP; 3TC/NVP/d4T; TDF/FTC +EFV or NVP and TDF+3TC+LPV/r. A composite adherence measure defined as not missing a dose and taking the correct dose and adhering to the correct frequency and correct schedule of drug administration was used to assess self-reported adherence over a period of three days. Selfreported adherence was validated with viral load test. Base line adherence was fixed at ≥95% adherence level. Significant test was fixed at p<0.05. We included 502 participants in the analysis. Median age for men was 42 years (IQR: 38 - 44 years) and women, 36 years (IQR: 30-40 years). Mean duration of therapy was 43 (16-70) months. Effective self-reported adherence was 97.3%. Only age and virologic suppression were significantly associated with adherence to ART. Forgetfullness (43%) was the major reason for non-adherence, while improvement in health condition (40%) was the main facilitator of adherence to the medications. Most participants achieved optimal adherence (≥95%) with high virologic suppression. Strategies to sustain optimal adherence, e.g., the use of fixed dose combinations (FDCs) and comprehensive adherence counselling should be maintained.

  1. Drug Susceptibility and Resistance Mutations After First-Line Failure in Resource Limited Settings

    PubMed Central

    Wallis, Carole L.; Aga, Evgenia; Ribaudo, Heather; Saravanan, Shanmugam; Norton, Michael; Stevens, Wendy; Kumarasamy, Nagalingeswaran; Bartlett, John; Katzenstein, David

    2014-01-01

    Background. The development of drug resistance to nucleoside reverse transcriptase inhibitors (NRTIs) and nonnucleoside reverse transcriptase inhibitors (NNRTIs) has been associated with baseline human immunodeficiency virus (HIV)-1 RNA level (VL), CD4 cell counts (CD4), subtype, and treatment failure duration. This study describes drug resistance and levels of susceptibility after first-line virologic failure in individuals from Thailand, South Africa, India, Malawi, Tanzania. Methods. CD4 and VL were captured at AIDs Clinical Trial Group (ACTG) A5230 study entry, a study of lopinavir/ritonavir (LPV/r) monotherapy after first-line virologic failure on an NNRTI regimen. HIV drug-resistance mutation associations with subtype, site, study entry VL, and CD4 were evaluated using Fisher exact and Kruskall–Wallis tests. Results. Of the 207 individuals who were screened for A5230, sequence data were available for 148 individuals. Subtypes observed: subtype C (n = 97, 66%) AE (n = 27, 18%), A1 (n = 12, 8%), and D (n = 10, 7%). Of the 148 individuals, 93% (n = 138) and 96% (n = 142) had at least 1 reverse transcriptase (RT) mutation associated with NRTI and NNRTI resistance, respectively. The number of NRTI mutations was significantly associated with a higher study screening VL and lower study screening CD4 (P < .001). Differences in drug-resistance patterns in both NRTI and NNRTI were observed by site. Conclusions. The degree of NNRTI and NRTI resistance after first-line virologic failure was associated with higher VL at study entry. Thirty-two percent of individuals remained fully susceptible to etravirine and rilpivirine, protease inhibitor resistance was rare. Some level of susceptibility to NRTI remained; however, VL monitoring and earlier virologic failure detection may result in lower NRTI resistance. PMID:24795328

  2. Emission current control system for multiple hollow cathode devices

    NASA Technical Reports Server (NTRS)

    Beattie, John R. (Inventor); Hancock, Donald J. (Inventor)

    1988-01-01

    An emission current control system for balancing the individual emission currents from an array of hollow cathodes has current sensors for determining the current drawn by each cathode from a power supply. Each current sensor has an output signal which has a magnitude proportional to the current. The current sensor output signals are averaged, the average value so obtained being applied to a respective controller for controlling the flow of an ion source material through each cathode. Also applied to each controller are the respective sensor output signals for each cathode and a common reference signal. The flow of source material through each hollow cathode is thereby made proportional to the current drawn by that cathode, the average current drawn by all of the cathodes, and the reference signal. Thus, the emission current of each cathode is controlled such that each is made substantially equal to the emission current of each of the other cathodes. When utilized as a component of a multiple hollow cathode ion propulsion motor, the emission current control system of the invention provides for balancing the thrust of the motor about the thrust axis and also for preventing premature failure of a hollow cathode source due to operation above a maximum rated emission current.

  3. Design Method of Digital Optimal Control Scheme and Multiple Paralleled Bridge Type Current Amplifier for Generating Gradient Magnetic Fields in MRI Systems

    NASA Astrophysics Data System (ADS)

    Watanabe, Shuji; Takano, Hiroshi; Fukuda, Hiroya; Hiraki, Eiji; Nakaoka, Mutsuo

    This paper deals with a digital control scheme of multiple paralleled high frequency switching current amplifier with four-quadrant chopper for generating gradient magnetic fields in MRI (Magnetic Resonance Imaging) systems. In order to track high precise current pattern in Gradient Coils (GC), the proposal current amplifier cancels the switching current ripples in GC with each other and designed optimum switching gate pulse patterns without influences of the large filter current ripple amplitude. The optimal control implementation and the linear control theory in GC current amplifiers have affinity to each other with excellent characteristics. The digital control system can be realized easily through the digital control implementation, DSPs or microprocessors. Multiple-parallel operational microprocessors realize two or higher paralleled GC current pattern tracking amplifier with optimal control design and excellent results are given for improving the image quality of MRI systems.

  4. Neural network based automatic limit prediction and avoidance system and method

    NASA Technical Reports Server (NTRS)

    Calise, Anthony J. (Inventor); Prasad, Jonnalagadda V. R. (Inventor); Horn, Joseph F. (Inventor)

    2001-01-01

    A method for performance envelope boundary cueing for a vehicle control system comprises the steps of formulating a prediction system for a neural network and training the neural network to predict values of limited parameters as a function of current control positions and current vehicle operating conditions. The method further comprises the steps of applying the neural network to the control system of the vehicle, where the vehicle has capability for measuring current control positions and current vehicle operating conditions. The neural network generates a map of current control positions and vehicle operating conditions versus the limited parameters in a pre-determined vehicle operating condition. The method estimates critical control deflections from the current control positions required to drive the vehicle to a performance envelope boundary. Finally, the method comprises the steps of communicating the critical control deflection to the vehicle control system; and driving the vehicle control system to provide a tactile cue to an operator of the vehicle as the control positions approach the critical control deflections.

  5. Constant-current control method of multi-function electromagnetic transmitter.

    PubMed

    Xue, Kaichang; Zhou, Fengdao; Wang, Shuang; Lin, Jun

    2015-02-01

    Based on the requirements of controlled source audio-frequency magnetotelluric, DC resistivity, and induced polarization, a constant-current control method is proposed. Using the required current waveforms in prospecting as a standard, the causes of current waveform distortion and current waveform distortion's effects on prospecting are analyzed. A cascaded topology is adopted to achieve 40 kW constant-current transmitter. The responsive speed and precision are analyzed. According to the power circuit of the transmitting system, the circuit structure of the pulse width modulation (PWM) constant-current controller is designed. After establishing the power circuit model of the transmitting system and the PWM constant-current controller model, analyzing the influence of ripple current, and designing an open-loop transfer function according to the amplitude-frequency characteristic curves, the parameters of the PWM constant-current controller are determined. The open-loop transfer function indicates that the loop gain is no less than 28 dB below 160 Hz, which assures the responsive speed of the transmitting system; the phase margin is 45°, which assures the stabilization of the transmitting system. Experimental results verify that the proposed constant-current control method can keep the control error below 4% and can effectively suppress load change caused by the capacitance of earth load.

  6. Constant-current control method of multi-function electromagnetic transmitter

    NASA Astrophysics Data System (ADS)

    Xue, Kaichang; Zhou, Fengdao; Wang, Shuang; Lin, Jun

    2015-02-01

    Based on the requirements of controlled source audio-frequency magnetotelluric, DC resistivity, and induced polarization, a constant-current control method is proposed. Using the required current waveforms in prospecting as a standard, the causes of current waveform distortion and current waveform distortion's effects on prospecting are analyzed. A cascaded topology is adopted to achieve 40 kW constant-current transmitter. The responsive speed and precision are analyzed. According to the power circuit of the transmitting system, the circuit structure of the pulse width modulation (PWM) constant-current controller is designed. After establishing the power circuit model of the transmitting system and the PWM constant-current controller model, analyzing the influence of ripple current, and designing an open-loop transfer function according to the amplitude-frequency characteristic curves, the parameters of the PWM constant-current controller are determined. The open-loop transfer function indicates that the loop gain is no less than 28 dB below 160 Hz, which assures the responsive speed of the transmitting system; the phase margin is 45°, which assures the stabilization of the transmitting system. Experimental results verify that the proposed constant-current control method can keep the control error below 4% and can effectively suppress load change caused by the capacitance of earth load.

  7. Adaptive Variable Bias Magnetic Bearing Control

    NASA Technical Reports Server (NTRS)

    Johnson, Dexter; Brown, Gerald V.; Inman, Daniel J.

    1998-01-01

    Most magnetic bearing control schemes use a bias current with a superimposed control current to linearize the relationship between the control current and the force it delivers. With the existence of the bias current, even in no load conditions, there is always some power consumption. In aerospace applications, power consumption becomes an important concern. In response to this concern, an alternative magnetic bearing control method, called Adaptive Variable Bias Control (AVBC), has been developed and its performance examined. The AVBC operates primarily as a proportional-derivative controller with a relatively slow, bias current dependent, time-varying gain. The AVBC is shown to reduce electrical power loss, be nominally stable, and provide control performance similar to conventional bias control. Analytical, computer simulation, and experimental results are presented in this paper.

  8. Development, Demonstration, and Control of a Testbed for Multiterminal HVDC System

    DOE PAGES

    Li, Yalong; Shi, Xiaojie M.; Liu, Bo; ...

    2016-10-21

    This paper presents the development of a scaled four-terminal high-voltage direct current (HVDC) testbed, including hardware structure, communication architecture, and different control schemes. The developed testbed is capable of emulating typical operation scenarios including system start-up, power variation, line contingency, and converter station failure. Some unique scenarios are also developed and demonstrated, such as online control mode transition and station re-commission. In particular, a dc line current control is proposed, through the regulation of a converter station at one terminal. By controlling a dc line current to zero, the transmission line can be opened by using relatively low-cost HVDC disconnectsmore » with low current interrupting capability, instead of the more expensive dc circuit breaker. Utilizing the dc line current control, an automatic line current limiting scheme is developed. As a result, when a dc line is overloaded, the line current control will be automatically activated to regulate current within the allowable maximum value.« less

  9. Methods, systems and apparatus for controlling operation of two alternating current (AC) machines

    DOEpatents

    Gallegos-Lopez, Gabriel [Torrance, CA; Nagashima, James M [Cerritos, CA; Perisic, Milun [Torrance, CA; Hiti, Silva [Redondo Beach, CA

    2012-06-05

    A system is provided for controlling two alternating current (AC) machines via a five-phase PWM inverter module. The system comprises a first control loop, a second control loop, and a current command adjustment module. The current command adjustment module operates in conjunction with the first control loop and the second control loop to continuously adjust current command signals that control the first AC machine and the second AC machine such that they share the input voltage available to them without compromising the target mechanical output power of either machine. This way, even when the phase voltage available to either one of the machines decreases, that machine outputs its target mechanical output power.

  10. Digitally Controllable Current Amplifier and Current Conveyors in Practical Application of Controllable Frequency Filter

    NASA Astrophysics Data System (ADS)

    Polak, Josef; Jerabek, Jan; Langhammer, Lukas; Sotner, Roman; Dvorak, Jan; Panek, David

    2016-07-01

    This paper presents the simulations results in comparison with the measured results of the practical realization of the multifunctional second order frequency filter with a Digitally Adjustable Current Amplifier (DACA) and two Dual-Output Controllable Current Conveyors (CCCII +/-). This filter is designed for use in current mode. The filter was designed of the single input multiple outputs (SIMO) type, therefore it has only one input and three outputs with individual filtering functions. DACA element used in a newly proposed circuit is present in form of an integrated chip and the current conveyors are implemented using the Universal Current Conveyor (UCC) chip with designation UCC-N1B. Proposed frequency filter enables independent control of the pole frequency using parameters of two current conveyors and also independent control of the quality factor by change of a current gain of DACA.

  11. Performance Assessment of Model-Based Optimal Feedforward and Feedback Current Profile Control in NSTX-U using the TRANSP Code

    NASA Astrophysics Data System (ADS)

    Ilhan, Z.; Wehner, W. P.; Schuster, E.; Boyer, M. D.; Gates, D. A.; Gerhardt, S.; Menard, J.

    2015-11-01

    Active control of the toroidal current density profile is crucial to achieve and maintain high-performance, MHD-stable plasma operation in NSTX-U. A first-principles-driven, control-oriented model describing the temporal evolution of the current profile has been proposed earlier by combining the magnetic diffusion equation with empirical correlations obtained at NSTX-U for the electron density, electron temperature, and non-inductive current drives. A feedforward + feedback control scheme for the requlation of the current profile is constructed by embedding the proposed nonlinear, physics-based model into the control design process. Firstly, nonlinear optimization techniques are used to design feedforward actuator trajectories that steer the plasma to a desired operating state with the objective of supporting the traditional trial-and-error experimental process of advanced scenario planning. Secondly, a feedback control algorithm to track a desired current profile evolution is developed with the goal of adding robustness to the overall control scheme. The effectiveness of the combined feedforward + feedback control algorithm for current profile regulation is tested in predictive simulations carried out in TRANSP. Supported by PPPL.

  12. Method for measuring and controlling beam current in ion beam processing

    DOEpatents

    Kearney, Patrick A.; Burkhart, Scott C.

    2003-04-29

    A method for producing film thickness control of ion beam sputter deposition films. Great improvements in film thickness control is accomplished by keeping the total current supplied to both the beam and suppressor grids of a radio frequency (RF) in beam source constant, rather than just the current supplied to the beam grid. By controlling both currents, using this method, deposition rates are more stable, and this allows the deposition of layers with extremely well controlled thicknesses to about 0.1%. The method is carried out by calculating deposition rates based on the total of the suppressor and beam currents and maintaining the total current constant by adjusting RF power which gives more consistent values.

  13. Method and apparatus for controlling the solenoid current of a solenoid valve which controls the amount of suction of air in an internal combustion engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiuchi, T.; Yasuoka, A.

    1988-05-24

    A method of controlling the solenoid current of a solenoid valve which controls suction air in an internal combustion engine, is described comprising the steps of: calculating a solenoid current control value as a function of engine operating conditions; detecting an engine coolant temperature corresponding to the solenoid temperature; determining a temperature correction value in accordance with the solenoid temperature; and calculating a driving signal for controlling the operation of the solenoid as a function of the solenoid current control value and the temperature correction value.

  14. 49 CFR 192.473 - External corrosion control: Interference currents.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false External corrosion control: Interference currents. 192.473 Section 192.473 Transportation Other Regulations Relating to Transportation (Continued... for Corrosion Control § 192.473 External corrosion control: Interference currents. (a) Each operator...

  15. 49 CFR 192.473 - External corrosion control: Interference currents.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false External corrosion control: Interference currents. 192.473 Section 192.473 Transportation Other Regulations Relating to Transportation (Continued... for Corrosion Control § 192.473 External corrosion control: Interference currents. (a) Each operator...

  16. 49 CFR 192.473 - External corrosion control: Interference currents.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false External corrosion control: Interference currents. 192.473 Section 192.473 Transportation Other Regulations Relating to Transportation (Continued... for Corrosion Control § 192.473 External corrosion control: Interference currents. (a) Each operator...

  17. 49 CFR 192.473 - External corrosion control: Interference currents.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false External corrosion control: Interference currents. 192.473 Section 192.473 Transportation Other Regulations Relating to Transportation (Continued... for Corrosion Control § 192.473 External corrosion control: Interference currents. (a) Each operator...

  18. 49 CFR 192.473 - External corrosion control: Interference currents.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false External corrosion control: Interference currents. 192.473 Section 192.473 Transportation Other Regulations Relating to Transportation (Continued... for Corrosion Control § 192.473 External corrosion control: Interference currents. (a) Each operator...

  19. Process for applying control variables having fractal structures

    DOEpatents

    Bullock, IV, Jonathan S.; Lawson, Roger L.

    1996-01-01

    A process and apparatus for the application of a control variable having a fractal structure to a body or process. The process of the present invention comprises the steps of generating a control variable having a fractal structure and applying the control variable to a body or process reacting in accordance with the control variable. The process is applicable to electroforming where first, second and successive pulsed-currents are applied to cause the deposition of material onto a substrate, such that the first pulsed-current, the second pulsed-current, and successive pulsed currents form a fractal pulsed-current waveform.

  20. Process for applying control variables having fractal structures

    DOEpatents

    Bullock, J.S. IV; Lawson, R.L.

    1996-01-23

    A process and apparatus are disclosed for the application of a control variable having a fractal structure to a body or process. The process of the present invention comprises the steps of generating a control variable having a fractal structure and applying the control variable to a body or process reacting in accordance with the control variable. The process is applicable to electroforming where first, second and successive pulsed-currents are applied to cause the deposition of material onto a substrate, such that the first pulsed-current, the second pulsed-current, and successive pulsed currents form a fractal pulsed-current waveform. 3 figs.

  1. Pulse-Width-Modulating Driver for Brushless dc Motor

    NASA Technical Reports Server (NTRS)

    Salomon, Phil M.

    1991-01-01

    High-current pulse-width-modulating driver for brushless dc motor features optical coupling of timing signals from low-current control circuitry to high-current motor-driving circuitry. Provides high electrical isolation of motor-power supply, helping to prevent fast, high-current motor-driving pulses from being coupled through power supplies into control circuitry, where they interfere with low-current control signals.

  2. Robust current control-based generalized predictive control with sliding mode disturbance compensation for PMSM drives.

    PubMed

    Liu, Xudong; Zhang, Chenghui; Li, Ke; Zhang, Qi

    2017-11-01

    This paper addresses the current control of permanent magnet synchronous motor (PMSM) for electric drives with model uncertainties and disturbances. A generalized predictive current control method combined with sliding mode disturbance compensation is proposed to satisfy the requirement of fast response and strong robustness. Firstly, according to the generalized predictive control (GPC) theory based on the continuous time model, a predictive current control method is presented without considering the disturbance, which is convenient to be realized in the digital controller. In fact, it's difficult to derive the exact motor model and parameters in the practical system. Thus, a sliding mode disturbance compensation controller is studied to improve the adaptiveness and robustness of the control system. The designed controller attempts to combine the merits of both predictive control and sliding mode control, meanwhile, the controller parameters are easy to be adjusted. Lastly, the proposed controller is tested on an interior PMSM by simulation and experiment, and the results indicate that it has good performance in both current tracking and disturbance rejection. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  3. An Optimal Current Observer for Predictive Current Controlled Buck DC-DC Converters

    PubMed Central

    Min, Run; Chen, Chen; Zhang, Xiaodong; Zou, Xuecheng; Tong, Qiaoling; Zhang, Qiao

    2014-01-01

    In digital current mode controlled DC-DC converters, conventional current sensors might not provide isolation at a minimized price, power loss and size. Therefore, a current observer which can be realized based on the digital circuit itself, is a possible substitute. However, the observed current may diverge due to the parasitic resistors and the forward conduction voltage of the diode. Moreover, the divergence of the observed current will cause steady state errors in the output voltage. In this paper, an optimal current observer is proposed. It achieves the highest observation accuracy by compensating for all the known parasitic parameters. By employing the optimal current observer-based predictive current controller, a buck converter is implemented. The converter has a convergently and accurately observed inductor current, and shows preferable transient response than the conventional voltage mode controlled converter. Besides, costs, power loss and size are minimized since the strategy requires no additional hardware for current sensing. The effectiveness of the proposed optimal current observer is demonstrated experimentally. PMID:24854061

  4. HBT-EP Program: MHD Dynamics and Active Control through 3D Fields and Currents

    NASA Astrophysics Data System (ADS)

    Navratil, G. A.; Bialek, J.; Brooks, J. W.; Byrne, P. J.; Desanto, S.; Levesque, J. P.; Mauel, M. E.; Stewart, I. G.; Hansen, C. J.

    2017-10-01

    The HBT-EP active mode control research program aims to: (i) advance understanding of the effects of 3D shaping on advanced tokamak fusion performance, (ii) resolve important MHD issues associated with disruptions, and (iii) measure and mitigate the effects of 3D scrape-off layer (SOL) currents through active and passive control of the plasma edge and conducting boundary structures. Comparison of kink mode structure and RMP response in circular versus diverted plasmas shows good agreement with DCON modeling. SOL current measurements have been used to study SOL current dynamics and current-sharing with the vacuum vessel wall during kink-mode growth and disruptions. A multi-chord extreme UV/soft X-ray array is being installed to provide detailed internal mode structure information. Internal local electrodes were used to apply local bias voltage at two radial locations to study the effect of rotation profile on MHD mode rotation and stability and radial current flow through the SOL. A GPU-based low latency control system using 96 inputs and 64 outputs to apply magnetic perturbations for active control of kink modes is extended to directly control the SOL currents for kink-mode control. An extensive array of SOL current monitors and edge drive electrodes are being installed for pioneering studies of helical edge current control. Supported by U.S. DOE Grant DE-FG02-86ER53222.

  5. A Sensorless Predictive Current Controlled Boost Converter by Using an EKF with Load Variation Effect Elimination Function

    PubMed Central

    Tong, Qiaoling; Chen, Chen; Zhang, Qiao; Zou, Xuecheng

    2015-01-01

    To realize accurate current control for a boost converter, a precise measurement of the inductor current is required to achieve high resolution current regulating. Current sensors are widely used to measure the inductor current. However, the current sensors and their processing circuits significantly contribute extra hardware cost, delay and noise to the system. They can also harm the system reliability. Therefore, current sensorless control techniques can bring cost effective and reliable solutions for various boost converter applications. According to the derived accurate model, which contains a number of parasitics, the boost converter is a nonlinear system. An Extended Kalman Filter (EKF) is proposed for inductor current estimation and output voltage filtering. With this approach, the system can have the same advantages as sensored current control mode. To implement EKF, the load value is necessary. However, the load may vary from time to time. This can lead to errors of current estimation and filtered output voltage. To solve this issue, a load variation elimination effect elimination (LVEE) module is added. In addition, a predictive average current controller is used to regulate the current. Compared with conventional voltage controlled system, the transient response is greatly improved since it only takes two switching cycles for the current to reach its reference. Finally, experimental results are presented to verify the stable operation and output tracking capability for large-signal transients of the proposed algorithm. PMID:25928061

  6. Design of laser diode driver with constant current and temperature control system

    NASA Astrophysics Data System (ADS)

    Wang, Ming-cai; Yang, Kai-yong; Wang, Zhi-guo; Fan, Zhen-fang

    2017-10-01

    A laser Diode (LD) driver with constant current and temperature control system is designed according to the LD working characteristics. We deeply researched the protection circuit and temperature control circuit based on thermos-electric cooler(TEC) cooling circuit and PID algorithm. The driver could realize constant current output and achieve stable temperature control of LD. Real-time feedback control method was adopted in the temperature control system to make LD work on its best temperature point. The output power variety and output wavelength shift of LD caused by current and temperature instability were decreased. Furthermore, the driving current and working temperature is adjustable according to specific requirements. The experiment result showed that the developed LD driver meets the characteristics of LD.

  7. Strategic model of national rabies control in Korea.

    PubMed

    Cheong, Yeotaek; Kim, Bongjun; Lee, Ki Joong; Park, Donghwa; Kim, Sooyeon; Kim, Hyeoncheol; Park, Eunyeon; Lee, Hyeongchan; Bae, Chaewun; Oh, Changin; Park, Seung-Yong; Song, Chang-Seon; Lee, Sang-Won; Choi, In-Soo; Lee, Joong-Bok

    2014-01-01

    Rabies is an important zoonosis in the public and veterinary healthy arenas. This article provides information on the situation of current rabies outbreak, analyzes the current national rabies control system, reviews the weaknesses of the national rabies control strategy, and identifies an appropriate solution to manage the current situation. Current rabies outbreak was shown to be present from rural areas to urban regions. Moreover, the situation worldwide demonstrates that each nation struggles to prevent or control rabies. Proper application and execution of the rabies control program require the overcoming of existing weaknesses. Bait vaccines and other complex programs are suggested to prevent rabies transmission or infection. Acceleration of the rabies control strategy also requires supplementation of current policy and of public information. In addition, these prevention strategies should be executed over a mid- to long-term period to control rabies.

  8. Sensorless Sinusoidal Drives for Fan and Pump Motors by V/f Control

    NASA Astrophysics Data System (ADS)

    Kiuchi, Mitsuyuki; Ohnishi, Tokuo

    This paper proposes sensorless sinusoidal driving methods of permanent magnet synchronous motors for fans and pumps by V/f control. The proposed methods are simple methods that control the motor peak current constant by voltage or frequency control, and are characterized by DC link current detection using a single shunt resistor at carrier wave signal bottom timing. As a result of the dumping factor from square torque load characteristics of fan and pump motors, it is possible to control stable starting and stable steady state by V/f control. In general, pressure losses as a result of the fluid pass of fan and pump systems are nearly constant; therefore, the flow rate and motor torque are determined by revolutions. Accordingly, high efficiency driving is possible by setting corresponding currents to q-axis currents (torque currents) at target revolutions. Because of the simple current detection and motor control methods, the proposed methods are optimum for fan and pump motor driving systems of home appliances.

  9. Variable current speed controller for eddy current motors

    DOEpatents

    Gerth, H.L.; Bailey, J.M.; Casstevens, J.M.; Dixon, J.H.; Griffith, B.O.; Igou, R.E.

    1982-03-12

    A speed control system for eddy current motors is provided in which the current to the motor from a constant frequency power source is varied by comparing the actual motor speed signal with a setpoint speed signal to control the motor speed according to the selected setpoint speed. A three-phase variable voltage autotransformer is provided for controlling the voltage from a three-phase power supply. A corresponding plurality of current control resistors is provided in series with each phase of the autotransformer output connected to inputs of a three-phase motor. Each resistor is connected in parallel with a set of normally closed contacts of plurality of relays which are operated by control logic. A logic circuit compares the selected speed with the actual motor speed obtained from a digital tachometer monitoring the motor spindle speed and operated the relays to add or substract resistance equally in each phase of the motor input to vary the motor current to control the motor at the selected speed.

  10. Photovoltaic power converter system with a controller configured to actively compensate load harmonics

    DOEpatents

    de Rooij, Michael Andrew; Steigerwald, Robert Louis; Delgado, Eladio Clemente

    2008-12-16

    Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

  11. Adaptive Fuzzy Hysteresis Band Current Controller for Four-Wire Shunt Active Filter

    NASA Astrophysics Data System (ADS)

    Hamoudi, F.; Chaghi, A.; Amimeur, H.; Merabet, E.

    2008-06-01

    This paper presents an adaptive fuzzy hysteresis band current controller for four-wire shunt active power filters to eliminate harmonics and to compensate reactive power in distribution systems in order to keep currents at the point of common coupling sinusoidal and in phase with the corresponding voltage and the cancel neutral current. The conventional hysteresis band known for its robustness and its advantage in current controlled applications is adapted with a fuzzy logic controller to change the bandwidth according to the operating point in order to keep the frequency modulation at tolerable limits. The algorithm used to identify the reference currents is based on the synchronous reference frame theory (dqγ). Finally, simulation results using Matlab/Simulink are given to validate the proposed control.

  12. Controllable Bidirectional dc Power Sources For Large Loads

    NASA Technical Reports Server (NTRS)

    Tripp, John S.; Daniels, Taumi S.

    1995-01-01

    System redesigned for greater efficiency, durability, and controllability. Modern electronically controlled dc power sources proposed to supply currents to six electromagnets used to position aerodynamic test model in wind tunnel. Six-phase bridge rectifier supplies load with large current at voltage of commanded magnitude and polarity. Current-feedback circuit includes current-limiting feature giving some protection against overload.

  13. Apparatus for electrode current control in linear MHD generators

    DOEpatents

    Demirjian, Ara M.; Solbes, Albert

    1984-01-01

    Apparatus for controlling a plurality of opposing, electrode, direct-currents at pre-set locations across a channel that comprises a converter for converting each electrode current into first and second periodic control signals which are 180.degree. out of phase with respect to each other and which have equal magnitudes corresponding to the magnitude of the associated electrode current; and couplers for magnetically coupling individual ones of the first control signals and for magnetically coupling individual ones of the second signals such that the corresponding electrode currents are equalized or rendered proportional by balancing the same in the same or constant ratios in accordance with the locations of the electrode currents.

  14. Voltage controlled current source

    DOEpatents

    Casne, Gregory M.

    1992-01-01

    A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

  15. Magnetically Controlled Variable Transformer

    NASA Technical Reports Server (NTRS)

    Kleiner, Charles T.

    1994-01-01

    Improved variable-transformer circuit, output voltage and current of which controlled by use of relatively small current supplied at relatively low power to control windings on its magnetic cores. Transformer circuits of this type called "magnetic amplifiers" because ratio between controlled output power and power driving control current of such circuit large. This ratio - power gain - can be as large as 100 in present circuit. Variable-transformer circuit offers advantages of efficiency, safety, and controllability over some prior variable-transformer circuits.

  16. Modeling and Dynamic Analysis of Paralleled dc/dc Converters With Master-Slave Current Sharing Control

    NASA Technical Reports Server (NTRS)

    Rajagopalan, J.; Xing, K.; Guo, Y.; Lee, F. C.; Manners, Bruce

    1996-01-01

    A simple, application-oriented, transfer function model of paralleled converters employing Master-Slave Current-sharing (MSC) control is developed. Dynamically, the Master converter retains its original design characteristics; all the Slave converters are forced to depart significantly from their original design characteristics into current-controlled current sources. Five distinct loop gains to assess system stability and performance are identified and their physical significance is described. A design methodology for the current share compensator is presented. The effect of this current sharing scheme on 'system output impedance' is analyzed.

  17. An Experimental Design of Bypass Magneto-Rheological (MR) damper

    NASA Astrophysics Data System (ADS)

    Rashid, MM; Aziz, Mohammad Abdul; Raisuddin Khan, Md.

    2017-11-01

    The magnetorheological (MR) fluid bypass damper fluid flow through a bypass by utilizing an external channel which allows the controllability of MR fluid in the channel. The Bypass MR damper (BMRD) contains a rectangular bypass flow channel, current controlled movable piston shaft arrangement and MR fluid. The static piston coil case is winding by a coil which is used inside the piston head arrangement. The current controlled coil case provides a magnetic flux through the BMRD cylinder for controllability. The high strength of alloy steel materials are used for making piston shaft which allows magnetic flux propagation throughout the BMRD cylinder. Using the above design materials, a Bypass MR damper is designed and tested. An excitation of current is applied during the experiment which characterizes the BMRD controllability. It is shown that the BMRD with external flow channel allows a high controllable damping force using an excitation current. The experimental result of damping force-displacement characteristics with current excitation and without current excitation are compared in this research. The BMRD model is validated by the experimental result at various frequencies and applied excitation current.

  18. Electronic system for high power load control. [solar arrays

    NASA Technical Reports Server (NTRS)

    Miller, E. L. (Inventor)

    1980-01-01

    Parallel current paths are divided into two groups, with control devices in the current paths of one group each having a current limiting resistor, and the control devices in the other group each having no limiting resistor, so that when the control devices of the second group are turned fully on, a short circuit is achieved by the arrangement of parallel current paths. Separate but coordinated control signals are provided to turn on the control devices of the first group and increase their conduction toward saturation as a function of control input, and when fully on, or shortly before, to turn on the control devices of the second group and increase their conduction toward saturation as a function of the control input as that input continues to increase. Electronic means may be used to generate signals. The system may be used for 1-V characteristic measurements of solar arrays as well as for other load control purposes.

  19. Real-time multi-DSP control of three-phase current-source unity power factor PWM rectifier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao Wang; Boon-Teck Ooi

    1993-07-01

    The design of a real-time multi-DSP controller for a high-quality six-valve three-phase current-source unity power factor PWM rectifier is discussed in this paper. With the decoupler preprocessor and the dynamic trilogic PWM trigger scheme, each of the three input currents can be controlled independently. Based on the a-b-c frame system model and the fast parallel computer control, the pole-placement control method is implemented successfully to achieve fast response in the ac currents. The low-frequency resonance in the ac filter L-C networks has been damped effectively. The experimental results are obtained from a 1-kVA bipolar transistor current-source PWM rectifier with amore » real-time controller using three TMS320C25 DSP's.« less

  20. Fuzzy Current-Mode Control and Stability Analysis

    NASA Technical Reports Server (NTRS)

    Kopasakis, George

    2000-01-01

    In this paper a current-mode control (CMC) methodology is developed for a buck converter by using a fuzzy logic controller. Conventional CMC methodologies are based on lead-lag compensation with voltage and inductor current feedback. In this paper the converter lead-lag compensation will be substituted with a fuzzy controller. A small-signal model of the fuzzy controller will also be developed in order to examine the stability properties of this buck converter control system. The paper develops an analytical approach, introducing fuzzy control into the area of CMC.

  1. Zener diode controls switching of large direct currents

    NASA Technical Reports Server (NTRS)

    1965-01-01

    High-current zener diode is connected in series with the positive input terminal of a dc supply to block the flow of direct current until a high-frequency control signal is applied across the zener diode. This circuit controls the switching of large dc signals.

  2. A fault-tolerant strategy based on SMC for current-controlled converters

    NASA Astrophysics Data System (ADS)

    Azer, Peter M.; Marei, Mostafa I.; Sattar, Ahmed A.

    2018-05-01

    The sliding mode control (SMC) is used to control variable structure systems such as power electronics converters. This paper presents a fault-tolerant strategy based on the SMC for current-controlled AC-DC converters. The proposed SMC is based on three sliding surfaces for the three legs of the AC-DC converter. Two sliding surfaces are assigned to control the phase currents since the input three-phase currents are balanced. Hence, the third sliding surface is considered as an extra degree of freedom which is utilised to control the neutral voltage. This action is utilised to enhance the performance of the converter during open-switch faults. The proposed fault-tolerant strategy is based on allocating the sliding surface of the faulty leg to control the neutral voltage. Consequently, the current waveform is improved. The behaviour of the current-controlled converter during different types of open-switch faults is analysed. Double switch faults include three cases: two upper switch fault; upper and lower switch fault at different legs; and two switches of the same leg. The dynamic performance of the proposed system is evaluated during healthy and open-switch fault operations. Simulation results exhibit the various merits of the proposed SMC-based fault-tolerant strategy.

  3. Off-axis current drive and real-time control of current profile in JT-60U

    NASA Astrophysics Data System (ADS)

    Suzuki, T.; Ide, S.; Oikawa, T.; Fujita, T.; Ishikawa, M.; Seki, M.; Matsunaga, G.; Hatae, T.; Naito, O.; Hamamatsu, K.; Sueoka, M.; Hosoyama, H.; Nakazato, M.; JT-60 Team

    2008-04-01

    Aiming at optimization of current profile in high-β plasmas for higher confinement and stability, a real-time control system of the minimum of the safety factor (qmin) using the off-axis current drive has been developed. The off-axis current drive can raise the safety factor in the centre and help to avoid instability that limits the performance of the plasma. The system controls the injection power of lower-hybrid waves, and hence its off-axis driven current in order to control qmin. The real-time control of qmin is demonstrated in a high-β plasma, where qmin follows the temporally changing reference qmin,ref from 1.3 to 1.7. Applying the control to another high-β discharge (βN = 1.7, βp = 1.5) with m/n = 2/1 neo-classical tearing mode (NTM), qmin was raised above 2 and the NTM was suppressed. The stored energy increased by 16% with the NTM suppressed, since the resonant rational surface was eliminated. For the future use for current profile control, current density profile for off-axis neutral beam current drive (NBCD) is for the first time measured, using the motional Stark effect diagnostic. Spatially localized NBCD profile was clearly observed at the normalized minor radius ρ of about 0.6-0.8. The location was also confirmed by multi-chordal neutron emission profile measurement. The total amount of the measured beam driven current was consistent with the theoretical calculation using the ACCOME code. The CD location in the calculation was inward shifted than the measurement.

  4. First-Principles-Driven Model-Based Optimal Control of the Current Profile in NSTX-U

    NASA Astrophysics Data System (ADS)

    Ilhan, Zeki; Barton, Justin; Wehner, William; Schuster, Eugenio; Gates, David; Gerhardt, Stefan; Kolemen, Egemen; Menard, Jonathan

    2014-10-01

    Regulation in time of the toroidal current profile is one of the main challenges toward the realization of the next-step operational goals for NSTX-U. A nonlinear, control-oriented, physics-based model describing the temporal evolution of the current profile is obtained by combining the magnetic diffusion equation with empirical correlations obtained at NSTX-U for the electron density, electron temperature, and non-inductive current drives. In this work, the proposed model is embedded into the control design process to synthesize a time-variant, linear-quadratic-integral, optimal controller capable of regulating the safety factor profile around a desired target profile while rejecting disturbances. Neutral beam injectors and the total plasma current are used as actuators to shape the current profile. The effectiveness of the proposed controller in regulating the safety factor profile in NSTX-U is demonstrated via closed-loop predictive simulations carried out in PTRANSP. Supported by PPPL.

  5. High-Speed Current dq PI Controller for Vector Controlled PMSM Drive

    PubMed Central

    Reaz, Mamun Bin Ibne; Rahman, Labonnah Farzana; Chang, Tae Gyu

    2014-01-01

    High-speed current controller for vector controlled permanent magnet synchronous motor (PMSM) is presented. The controller is developed based on modular design for faster calculation and uses fixed-point proportional-integral (PI) method for improved accuracy. Current dq controller is usually implemented in digital signal processor (DSP) based computer. However, DSP based solutions are reaching their physical limits, which are few microseconds. Besides, digital solutions suffer from high implementation cost. In this research, the overall controller is realizing in field programmable gate array (FPGA). FPGA implementation of the overall controlling algorithm will certainly trim down the execution time significantly to guarantee the steadiness of the motor. Agilent 16821A Logic Analyzer is employed to validate the result of the implemented design in FPGA. Experimental results indicate that the proposed current dq PI controller needs only 50 ns of execution time in 40 MHz clock, which is the lowest computational cycle for the era. PMID:24574913

  6. Development of Real Time Implementation of 5/5 Rule based Fuzzy Logic Controller Shunt Active Power Filter for Power Quality Improvement

    NASA Astrophysics Data System (ADS)

    Puhan, Pratap Sekhar; Ray, Pravat Kumar; Panda, Gayadhar

    2016-12-01

    This paper presents the effectiveness of 5/5 Fuzzy rule implementation in Fuzzy Logic Controller conjunction with indirect control technique to enhance the power quality in single phase system, An indirect current controller in conjunction with Fuzzy Logic Controller is applied to the proposed shunt active power filter to estimate the peak reference current and capacitor voltage. Current Controller based pulse width modulation (CCPWM) is used to generate the switching signals of voltage source inverter. Various simulation results are presented to verify the good behaviour of the Shunt active Power Filter (SAPF) with proposed two levels Hysteresis Current Controller (HCC). For verification of Shunt Active Power Filter in real time, the proposed control algorithm has been implemented in laboratory developed setup in dSPACE platform.

  7. 40 CFR 63.41 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... existing equipment will be equivalent to that level of control currently achieved by other well-controlled similar sources (i.e., equivalent to the level of control that would be provided by a current BACT, LAER... control equipment will be equivalent to the percent control efficiency provided by the control equipment...

  8. 40 CFR 63.41 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... existing equipment will be equivalent to that level of control currently achieved by other well-controlled similar sources (i.e., equivalent to the level of control that would be provided by a current BACT, LAER... control equipment will be equivalent to the percent control efficiency provided by the control equipment...

  9. 40 CFR 63.41 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... existing equipment will be equivalent to that level of control currently achieved by other well-controlled similar sources (i.e., equivalent to the level of control that would be provided by a current BACT, LAER... control equipment will be equivalent to the percent control efficiency provided by the control equipment...

  10. 40 CFR 63.41 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... existing equipment will be equivalent to that level of control currently achieved by other well-controlled similar sources (i.e., equivalent to the level of control that would be provided by a current BACT, LAER... control equipment will be equivalent to the percent control efficiency provided by the control equipment...

  11. 40 CFR 63.41 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... existing equipment will be equivalent to that level of control currently achieved by other well-controlled similar sources (i.e., equivalent to the level of control that would be provided by a current BACT, LAER... control equipment will be equivalent to the percent control efficiency provided by the control equipment...

  12. Stabilizing the baseline current of a microbial fuel cell-based biosensor through overpotential control under non-toxic conditions.

    PubMed

    Stein, Nienke E; Hamelers, Hubertus V M; Buisman, Cees N J

    2010-04-01

    A MFC-based biosensor can act as online toxicity sensor. Electrical current is a direct linear measure for metabolic activity of electrochemically active microorganisms. Microorganisms gain energy from anodic overpotential and current strongly depends on anodic overpotential. Therefore control of anodic overpotential is necessary to detect toxic events and prevent false positive alarms. Anodic overpotential and thus current is influenced by anode potential, pH, substrate and bicarbonate concentrations. In terms of overpotential all factor showed a comparable effect, anode potential 1.2% change in current density per mV, pH 0.43%/mV, bicarbonate 0.75%/mV and acetate 0.8%/mV. At acetate saturation the maximum acetate conversion rate is reached and with that a constant bicarbonate concentration. Control of acetate and bicarbonate concentration can be less strict than control of anode potential and pH. Current density changes due to changing anode potential and pH are in the same order of magnitude as changes due to toxicity. Strict control of pH and anode potential in a small range is required. The importance of anodic overpotential control for detection of toxic compounds is shown. To reach a stable baseline current under nontoxic conditions a MFC-based biosensor should be operated at controlled anode potential, controlled pH and saturated substrate concentrations. 2009 Elsevier B.V. All rights reserved.

  13. Improvement of the grid-connect current quality using novel proportional-integral controller for photovoltaic inverters.

    PubMed

    Cheng, Yuhua; Chen, Kai; Bai, Libing; Yang, Jing

    2014-02-01

    Precise control of the grid-connected current is a challenge in photovoltaic inverter research. Traditional Proportional-Integral (PI) control technology cannot eliminate steady-state error when tracking the sinusoidal signal from the grid, which results in a very high total harmonic distortion in the grid-connected current. A novel PI controller has been developed in this paper, in which the sinusoidal wave is discretized into an N-step input signal that is decided by the control frequency to eliminate the steady state error of the system. The effect of periodical error caused by the dead zone of the power switch and conduction voltage drop can be avoided; the current tracking accuracy and current harmonic content can also be improved. Based on the proposed PI controller, a 700 W photovoltaic grid-connected inverter is developed and validated. The improvement has been demonstrated through experimental results.

  14. Modeling and Dynamic Analysis of Paralleled of dc/dc Converters with Master-Slave Current Sharing Control

    NASA Technical Reports Server (NTRS)

    Rajagopalan, J.; Xing, K.; Guo, Y.; Lee, F. C.; Manners, Bruce

    1996-01-01

    A simple, application-oriented, transfer function model of paralleled converters employing Master-Slave Current-sharing (MSC) control is developed. Dynamically, the Master converter retains its original design characteristics; all the Slave converters are forced to depart significantly from their original design characteristics into current-controlled current sources. Five distinct loop gains to assess system stability and performance are identified and their physical significance is described. A design methodology for the current share compensator is presented. The effect of this current sharing scheme on 'system output impedance' is analyzed.

  15. Automatic Control Of Length Of Welding Arc

    NASA Technical Reports Server (NTRS)

    Iceland, William F.

    1991-01-01

    Nonlinear relationships among current, voltage, and length stored in electronic memory. Conceptual microprocessor-based control subsystem maintains constant length of welding arc in gas/tungsten arc-welding system, even when welding current varied. Uses feedback of current and voltage from welding arc. Directs motor to set position of torch according to previously measured relationships among current, voltage, and length of arc. Signal paths marked "calibration" or "welding" used during those processes only. Other signal paths used during both processes. Control subsystem added to existing manual or automatic welding system equipped with automatic voltage control.

  16. Analysis of Proportional Integral and Optimized Proportional Integral Controllers for Resistance Spot Welding System (RSWS) - A Performance Perspective

    NASA Astrophysics Data System (ADS)

    Rama Subbanna, S.; Suryakalavathi, M., Dr.

    2017-08-01

    This paper is an attempt to accomplish a performance analysis of the different control techniques on spikes reduction method applied on the medium frequency transformer based DC spot welding system. Spike reduction is an important factor to be considered while spot welding systems are concerned. During normal RSWS operation welding transformer’s magnetic core can become saturated due to the unbalanced resistances of both transformer secondary windings and different characteristics of output rectifier diodes, which causes current spikes and over-current protection switch-off of the entire system. The current control technique is a piecewise linear control technique that is inspired from the DC-DC converter control algorithms to register a novel spike reduction method in the MFDC spot welding applications. Two controllers that were used for the spike reduction portion of the overall applications involve the traditional PI controller and Optimized PI controller. Care is taken such that the current control technique would maintain a reduced spikes in the primary current of the transformer while it reduces the Total Harmonic Distortion. The performance parameter that is involved in the spikes reduction technique is the THD, Percentage of current spike reduction for both techniques. Matlab/SimulinkTM based simulation is carried out for the MFDC RSWS with KW and results are tabulated for the PI and Optimized PI controllers and a tradeoff analysis is carried out.

  17. A simplified controller and detailed dynamics of constant off-time peak current control

    NASA Astrophysics Data System (ADS)

    Van den Bossche, Alex; Dimitrova, Ekaterina; Valchev, Vencislav; Feradov, Firgan

    2017-09-01

    A fast and reliable current control is often the base of power electronic converters. The traditional constant frequency peak control is unstable above 50 % duty ratio. In contrast, the constant off-time peak current control (COTCC) is unconditionally stable and fast, so it is worth analyzing it. Another feature of the COTCC is that one can combine a current control together with a current protection. The time dynamics show a zero-transient response, even when the inductor changes in a wide range. It can also be modeled as a special transfer function for all frequencies. The article shows also that it can be implemented in a simple analog circuit using a wide temperature range IC, such as the LM2903, which is compatible with PV conversion and automotive temperature range. Experiments are done using a 3 kW step-up converter. A drawback is still that the principle does not easily fit in usual digital controllers up to now.

  18. High performance advanced tokamak regimes in DIII-D for next-step experiments

    NASA Astrophysics Data System (ADS)

    Greenfield, C. M.; Murakami, M.; Ferron, J. R.; Wade, M. R.; Luce, T. C.; Petty, C. C.; Menard, J. E.; Petrie, T. W.; Allen, S. L.; Burrell, K. H.; Casper, T. A.; DeBoo, J. C.; Doyle, E. J.; Garofalo, A. M.; Gorelov, I. A.; Groebner, R. J.; Hobirk, J.; Hyatt, A. W.; Jayakumar, R. J.; Kessel, C. E.; La Haye, R. J.; Jackson, G. L.; Lohr, J.; Makowski, M. A.; Pinsker, R. I.; Politzer, P. A.; Prater, R.; Strait, E. J.; Taylor, T. S.; West, W. P.; DIII-D Team

    2004-05-01

    Advanced Tokamak (AT) research in DIII-D [K. H. Burrell for the DIII-D Team, in Proceedings of the 19th Fusion Energy Conference, Lyon, France, 2002 (International Atomic Energy Agency, Vienna, 2002) published on CD-ROM] seeks to provide a scientific basis for steady-state high performance operation in future devices. These regimes require high toroidal beta to maximize fusion output and poloidal beta to maximize the self-driven bootstrap current. Achieving these conditions requires integrated, simultaneous control of the current and pressure profiles, and active magnetohydrodynamic stability control. The building blocks for AT operation are in hand. Resistive wall mode stabilization via plasma rotation and active feedback with nonaxisymmetric coils allows routine operation above the no-wall beta limit. Neoclassical tearing modes are stabilized by active feedback control of localized electron cyclotron current drive (ECCD). Plasma shaping and profile control provide further improvements. Under these conditions, bootstrap supplies most of the current. Steady-state operation requires replacing the remaining Ohmic current, mostly located near the half radius, with noninductive external sources. In DIII-D this current is provided by ECCD, and nearly stationary AT discharges have been sustained with little remaining Ohmic current. Fast wave current drive is being developed to control the central magnetic shear. Density control, with divertor cryopumps, of AT discharges with edge localized moding H-mode edges facilitates high current drive efficiency at reactor relevant collisionalities. A sophisticated plasma control system allows integrated control of these elements. Close coupling between modeling and experiment is key to understanding the separate elements, their complex nonlinear interactions, and their integration into self-consistent high performance scenarios. Progress on this development, and its implications for next-step devices, will be illustrated by results of recent experiment and simulation efforts.

  19. Force analysis of magnetic bearings with power-saving controls

    NASA Technical Reports Server (NTRS)

    Johnson, Dexter; Brown, Gerald V.; Inman, Daniel J.

    1992-01-01

    Most magnetic bearing control schemes use a bias current with a superimposed control current to linearize the relationship between the control current and the force it delivers. For most operating conditions, the existence of the bias current requires more power than alternative methods that do not use conventional bias. Two such methods are examined which diminish or eliminate bias current. In the typical bias control scheme it is found that for a harmonic control force command into a voltage limited transconductance amplifier, the desired force output is obtained only up to certain combinations of force amplitude and frequency. Above these values, the force amplitude is reduced and a phase lag occurs. The power saving alternative control schemes typically exhibit such deficiencies at even lower command frequencies and amplitudes. To assess the severity of these effects, a time history analysis of the force output is performed for the bias method and the alternative methods. Results of the analysis show that the alternative approaches may be viable. The various control methods examined were mathematically modeled using nondimensionalized variables to facilitate comparison of the various methods.

  20. Space station contamination control study: Internal combustion, phase 1

    NASA Technical Reports Server (NTRS)

    Ruggeri, Robert T.

    1987-01-01

    Contamination inside Space Station modules was studied to determine the best methods of controlling contamination. The work was conducted in five tasks that identified existing contamination control requirements, analyzed contamination levels, developed outgassing specification for materials, wrote a contamination control plan, and evaluated current materials of offgassing tests used by NASA. It is concluded that current contamination control methods can be made to function on the Space Station for up to 1000 days, but that current methods are deficient for periods longer than about 1000 days.

  1. MOSFET Power Controller

    NASA Technical Reports Server (NTRS)

    Mitchell, J.; Jones, K.

    1986-01-01

    High current and voltage controlled remotely. Remote Power Conroller includes two series-connected banks of parallel-connected MOSFET's to withstand high current and voltage. Voltage sharing between switch banks, low-impedance, gate-drive circuits used. Provided controlled range for turn on. Individually trimmable to insure simultaneous switching within few nanoseconds during both turn on and turn off. Control circuit for each switch bank and over-current trip circuit float independently and supplied power via transformer T1 from inverter. Control of floating stages by optocouplers.

  2. Adaptive PI control strategy for flat permanent magnet linear synchronous motor vibration suppression

    NASA Astrophysics Data System (ADS)

    Meng, Fanwei; Liu, Chengying; Li, Zhijun; Wang, Liping

    2013-01-01

    Due to low damping ratio, flat permanent magnet linear synchronous motor's vibration is difficult to be damped and the accuracy is limited. The vibration suppressing results are not good enough in the existing research because only the longitudinal direction vibration is considered while the normal direction vibration is neglected. The parameters of the direct-axis current controller are set to be the same as those of the quadrature-axis current controller commonly. This causes contradiction between signal noise and response. To suppress the vibration, the electromagnetic force model of the flat permanent magnet synchronous linear motor is formulated first. Through the analysis of the effect that direct-axis current noise and quadrature-axis current noise have on both direction vibration, it can be declared that the conclusion that longitudinal direction vibration is only related to the quadrature-axis current noise while the normal direction vibration is related to both the quadrature-axis current noise and direct-axis current noise. Then, the simulation test on current loop with a low-pass filter is conducted and the results show that the low-pass filter can not suppress the vibration but makes the vibration more severe. So a vibration suppressing strategy that the proportional gain of direct-axis current controller adapted according to quadrature-axis reference current is proposed. This control strategy can suppress motor vibration by suppressing direct-axis current noise. The experiments results about the effect of K p and T i on normal direction vibration, longitudinal vibration and the position step response show that this strategy suppresses vibration effectively while the motor's motion performance is not affected. The maximum reduction of vibration can be up to 40%. In addition, current test under rated load condition is also conducted and the results show that the control strategy can avoid the conflict between the direct-axis current and the quadrature-axis current under typical load. Adaptive PI control strategy can effectively suppress the flat permanent magnet linear synchronous motor's vibration without affecting the motor's performance.

  3. An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions.

    PubMed

    Naderipour, Amirreza; Asuhaimi Mohd Zin, Abdullah; Bin Habibuddin, Mohd Hafiz; Miveh, Mohammad Reza; Guerrero, Josep M

    2017-01-01

    In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method.

  4. An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions

    PubMed Central

    Naderipour, Amirreza; Asuhaimi Mohd Zin, Abdullah; Bin Habibuddin, Mohd Hafiz; Miveh, Mohammad Reza; Guerrero, Josep M.

    2017-01-01

    In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method. PMID:28192436

  5. 40 CFR 450.21 - Effluent limitations reflecting the best practicable technology currently available (BPT).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology currently available (BPT). (a) Erosion and sediment controls. Design, install and... minimum, such controls must be designed, installed and maintained to: (1) Control stormwater volume and... appropriate controls. (d) Pollution prevention measures. Design, install, implement, and maintain effective...

  6. 40 CFR 450.21 - Effluent limitations reflecting the best practicable technology currently available (BPT).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... control technology currently available (BPT). (a) Erosion and sediment controls. Design, install and... minimum, such controls must be designed, installed and maintained to: (1) Control stormwater volume and... appropriate controls. (d) Pollution prevention measures. Design, install, implement, and maintain effective...

  7. How consistent are global long-term satellite LAI products in terms of interannual variability and trend?

    NASA Astrophysics Data System (ADS)

    Jiang, C.; Ryu, Y.; Fang, H.

    2016-12-01

    Proper usage of global satellite LAI products requires comprehensive evaluation. To address this issue, the Committee on Earth Observation Satellites (CEOS) Land Product Validation (LPV) subgroup proposed a four-stage validation hierarchy. During the past decade, great efforts have been made following this validation framework, mainly focused on absolute magnitude, seasonal trajectory, and spatial pattern of those global satellite LAI products. However, interannual variability and trends of global satellite LAI products have been investigated marginally. Targeting on this gap, we made an intercomparison between seven global satellite LAI datasets, including four short-term ones: MODIS C5, MODIS C6, GEOV1, MERIS, and three long-term products ones: LAI3g, GLASS, and GLOBMAP. We calculated global annual LAI time series for each dataset, among which we found substantial differences. During the overlapped period (2003 - 2011), MODIS C5, GLASS and GLOBMAP have positive correlation (r > 0.6) between each other, while MODIS C6, GEOV1, MERIS, and LAI3g are highly consistent (r > 0.7) in interannual variations. However, the previous three datasets show negative trends, all of which use MODIS C5 reflectance data, whereas the latter four show positive trends, using MODIS C6, SPOT/VGT, ENVISAT/MERIS, and NOAA/AVHRR, respectively. During the pre-MODIS era (1982 - 1999), the three AVHRR-based datasets (LAI3g, GLASS and GLOBMAP) agree well (r > 0.7), yet all of them show oscillation related with NOAA platform changes. In addition, both GLASS and GLOBMAP show clear cut-points around 2000 when they move from AVHRR to MODIS. Such inconsistency is also visible for GEOV1, which uses SPOT-4 and SPOT-5 before and after 2002. We further investigate the map-to-map deviations among these products. This study highlights that continuous sensor calibration and cross calibration are essential to obtain reliable global LAI time series.

  8. CT imaging-based determination and classification of anatomic variations of left gastric vein.

    PubMed

    Wu, Yongyou; Chen, Guangqiang; Wu, Pengfei; Zhu, Jianbin; Peng, Wei; Xing, Chungen

    2017-03-01

    Precise determination and classification of left gastric vein (LGV) anatomy are helpful in planning for gastric surgery, in particular, for resection of gastric cancer. However, the anatomy of LGV is highly variable. A systematic classification of its variations is still to be proposed. We aimed to investigate the anatomical variations in LGV using CT imaging and develop a new nomenclature system. We reviewed CT images and tracked the course of LGV in 825 adults. The frequencies of common and variable LGV anatomical courses were recorded. Anatomic variations of LGV were proposed and classified into different types mainly based on its courses. The inflow sites of LGV into the portal system were also considered if common hepatic artery (CHA) or splenic artery (SA) could not be used as a frame of reference due to variations. Detailed anatomy and courses of LGV were depicted on CT images. Using CHA and SA as the frames of reference, the routes of LGV were divided into six types (i.e., PreS, RetroS, Mid, PreCH, RetroCH, and Supra). The inflow sites were classified into four types (i.e., PV, SV, PSV, and LPV). The new classification was mainly based on the courses of LGV, which was validated with MDCT in the 805 cases with an identifiable LGV, namely type I, RetroCH, 49.8 % (401/805); type II, PreS, 20.6 % (166/805); type III, Mid, 20.0 % (161/805); type IV, RetroS, 7.3 % (59/805); type V, Supra, 1.5 % (12/805); and type VI, PreCH, 0.7 % (6/805). Type VII, designated to the cases in which SA and CHA could not be used as frames of reference, was not observed in this series. Detailed depiction of the anatomy and courses of LGV on CT images allowed us to evaluate and develop a new classification and nomenclature system for the anatomical variations of LGV.

  9. [Analysis of costs and cost-effectiveness of preferred GESIDA/National AIDS Plan regimens for initial antiretroviral therapy in human immunodeficiency virus infected adult patients in 2013].

    PubMed

    Blasco, Antonio Javier; Llibre, Josep M; Arribas, José Ramón; Boix, Vicente; Clotet, Bonaventura; Domingo, Pere; González-García, Juan; Knobel, Hernando; López, Juan Carlos; Lozano, Fernando; Miró, José M; Podzamczer, Daniel; Santamaría, Juan Miguel; Tuset, Montserrat; Zamora, Laura; Lázaro, Pablo; Gatell, Josep M

    2013-11-01

    The GESIDA and National AIDS Plan panel of experts have proposed "preferred regimens" of antiretroviral treatment (ART) as initial therapy in HIV infected patients for 2013. The objective of this study is to evaluate the costs and effectiveness of initiating treatment with these "preferred regimens". An economic assessment of costs and effectiveness (cost/effectiveness) was performed using decision tree analysis models. Effectiveness was defined as the probability of having viral load <50copies/mL at week48, in an intention-to-treat analysis. Cost of initiating treatment with an ART regime was defined as the costs of ART and its consequences (adverse effects, changes of ART regime and drug resistance analyses) during the first 48weeks. The perspective of the analysis is that of the National Health System was applied, only taking into account differential direct costs: ART (official prices), management of adverse effects, resistance studies, and determination of HLA B*5701. The setting is Spain and the costs are those of 2013. A sensitivity deterministic analysis was performed, constructing three scenarios for each regimen: baseline, most favourable, and most unfavourable cases. In the baseline case scenario, the cost of initiating treatment ranges from 6,747euros for TDF/FTC+NVP to 12,059euros for TDF/FTC+RAL. The effectiveness ranges between 0.66 for ABC/3TC+LPV/r and ABC/3TC+ATV/r, and 0.87 for TDF/FTC+RAL and ABC/3TC+RAL. Effectiveness, in terms of cost/effectiveness, varies between 8,396euros and 13,930euros per responder at 48weeks, for TDF/FTC/RPV and TDF/FTC+RAL, respectively. Taking ART at official prices, the most effective regimen was TDF/FTC/RPV, followed by the rest of non-nucleoside containing regimens. The sensitivity analysis confirms the robustness of these findings. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  10. Frequency of Antiretroviral Resistance Mutations among Infants Exposed to Single-Dose Nevirapine and Short Course Maternal Antiretroviral Regimens: ACTG A5207.

    PubMed

    Hitti, Jane; Halvas, Elias K; Zheng, Lu; Panousis, Constantinos G; Kabanda, Joseph; Taulo, Frank; Kumarasamy, Nagalingeswaran; Pape, Jean William; Lalloo, Umesh; Sprenger, Heather; Klingman, Karin L; Chan, Ellen S; McMahon, Deborah; Mellors, John W

    2014-11-01

    Intrapartum single-dose nevirapine (sdNVP) reduces HIV-1 perinatal transmission but selects NVP resistance among mothers and infants. We evaluated the frequency of antiretroviral resistance among infants with intrauterine HIV-1 infection exposed to sdNVP and maternal antenatal or breastfeeding antiretroviral therapy. This analysis included 429 infants from sub-Saharan Africa, India and Haiti whose 422 mothers received sdNVP plus maternal study treatment. At entry mothers had CD4>250/μL and were ART-naïve except for antenatal ZDV per local standard of care. Maternal study treatment started intrapartum and included ZDV/3TC, TDF/FTC or LPV/r for 7 or 21 days in a randomized factorial design. Infants received sdNVP study treatment and ZDV if local standard of care. Infant HIV RNA or DNA PCR and samples for genotype were obtained at birth and weeks 2, 4 and 12; infants who ever breast-fed were also tested at weeks 16, 24, 48 and 96. Samples from HIV-1-infected infants were tested for drug resistance by population genotype (ViroSeq). NVP or NRTI resistance mutations were assessed using the IAS-USA mutation list. Perinatal HIV-1 transmission occurred in 17 (4.0%) infants including 12 intrauterine infections. Resistance mutations were detected among 5 (42%) intrauterine-infected infants; of these, 3 had mutations conferring resistance to NVP alone, 1 had resistance to NRTI alone, and 1 had dual-class resistance mutations. Among the 2 infants with NRTI mutations, one (K70R) was likely maternally transmitted and one (K65R) occurred in the context of breastfeeding exposure to maternal antiretroviral therapy. Infants with intrauterine HIV infection are at risk of acquiring resistance mutations from exposure to maternal antiretroviral medications intrapartum and/or during breastfeeding. New approaches are needed to lower the risk of antiretroviral resistance in these infants.

  11. Electropneumatic transducer automatically limits motor current

    NASA Technical Reports Server (NTRS)

    Lovitt, T. F.

    1966-01-01

    Pneumatic controller regulates the load on a centrifugal freon compressor in a water cooling system, thus limiting the current input to an electric motor driving it. An electromechanical transducer monitoring the motor input current sends out air signals which indicate changes in the current to the pneumatic controller.

  12. Stabilizing effect of helical current drive on tearing modes

    NASA Astrophysics Data System (ADS)

    Yuan, Y.; Lu, X. Q.; Dong, J. Q.; Gong, X. Y.; Zhang, R. B.

    2018-01-01

    The effect of helical driven current on the m = 2/n = 1 tearing mode is studied numerically in a cylindrical geometry using the method of reduced magneto-hydro-dynamic simulation. The results show that the local persistent helical current drive from the beginning time can be applied to control the tearing modes, and will cause a rebound effect called flip instability when the driven current reaches a certain value. The current intensity threshold value for the occurrence of flip instability is about 0.00087I0. The method of controlling the development of tearing mode with comparative economy is given. If the local helical driven current is discontinuous, the magnetic island can be controlled within a certain range, and then, the tearing modes stop growing; thus, the flip instability can be avoided. We also find that the flip instability will become impatient with delay injection of the driven current because the high order harmonics have been developed in the original O-point. The tearing mode instability can be controlled by using the electron cyclotron current drive to reduce the gradient of the current intensity on the rational surfaces.

  13. Advanced Controller Developed for the Free-Piston Stirling Convertor

    NASA Technical Reports Server (NTRS)

    Gerber, Scott S.

    2005-01-01

    A free-piston Stirling power convertor is being considered as an advanced power-conversion technology for future NASA deep-space missions requiring long-life radioisotope power systems. The NASA Glenn Research Center has identified key areas where advanced technologies can enhance the capability of Stirling energy-conversion systems. One of these is power electronic controls. Current power-conversion technology for Glenn-tested Stirling systems consists of an engine-driven linear alternator generating an alternating-current voltage controlled by a tuning-capacitor-based alternating-current peak voltage load controller. The tuning capacitor keeps the internal alternator electromotive force (EMF) in phase with its respective current (i.e., passive power factor correction). The alternator EMF is related to the piston velocity, which must be kept in phase with the alternator current in order to achieve stable operation. This tuning capacitor, which adds volume and mass to the overall Stirling convertor, can be eliminated if the controller can actively drive the magnitude and phase of the alternator current.

  14. AC/DC current ratio in a current superimposition variable flux reluctance machine

    NASA Astrophysics Data System (ADS)

    Kohara, Akira; Hirata, Katsuhiro; Niguchi, Noboru; Takahara, Kazuaki

    2018-05-01

    We have proposed a current superimposition variable flux reluctance machine for traction motors. The torque-speed characteristics of this machine can be controlled by increasing or decreasing the DC current. In this paper, we discuss an AC/DC current ratio in the current superimposition variable flux reluctance machine. The structure and control method are described, and the characteristics are computed using FEA in several AC/DC ratios.

  15. Systems and methods for providing power to a load based upon a control strategy

    DOEpatents

    Perisic, Milun; Kajouke, Lateef A; Ransom, Ray M

    2013-12-24

    Systems and methods are provided for an electrical system. The electrical system includes a load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage from the voltage source through the interface and to provide a voltage and current to the load. Wherein, when the controller is in a constant voltage mode, the controller provides a constant voltage to the load, when the controller is in a constant current mode, the controller provides a constant current to the load, and when the controller is in a constant power mode, the controller provides a constant power to the load.

  16. Control system for 5 MW neutral beam ion source for SST1

    NASA Astrophysics Data System (ADS)

    Patel, G. B.; Onali, Raja; Sharma, Vivek; Suresh, S.; Tripathi, V.; Bandyopadhyay, M.; Singh, N. P.; Thakkar, Dipal; Gupta, L. N.; Singh, M. J.; Patel, P. J.; Chakraborty, A. K.; Baruah, U. K.; Mattoo, S. K.

    2006-01-01

    This article describes the control system for a 5MW ion source of the NBI (neutral beam injector) for steady-state superconducting tokamak-1 (SST-1). The system uses both hardware and software solutions. It comprises a DAS (data acquisition system) and a control system. The DAS is used to read the voltage and current signals from eight filament heater power supplies and 24 discharge power supplies. The control system is used to adjust the filament heater current in order to achieve an effective control on the discharge current in the plasma box. The system consists of a VME (Verse Module Eurocard) system and C application program running on a VxWorks™ real-time operating system. A PID (proportional, integral, and differential) algorithm is used to control the filament heater current. Experiments using this system have shown that the discharge current can be controlled within 1% accuracy for a PID loop time of 20ms. Response of the control system to the pressure variation of the gas in the chamber has also been studied and compared with the results obtained from those of an uncontrolled system. The present approach increases the flexibility of the control system. It not only eases the control of the plasma but also allows an easy changeover to various operation scenarios.

  17. Study of a control strategy for grid side converter in doubly- fed wind power system

    NASA Astrophysics Data System (ADS)

    Zhu, D. J.; Tan, Z. L.; Yuan, F.; Wang, Q. Y.; Ding, M.

    2016-08-01

    The grid side converter is an important part of the excitation system of doubly-fed asynchronous generator used in wind power system. As a three-phase voltage source PWM converter, it can not only transfer slip power in the form of active power, but also adjust the reactive power of the grid. This paper proposed a control approach for improving its performance. In this control approach, the dc voltage is regulated by a sliding mode variable structure control scheme and current by a variable structure controller based on the input output linearization. The theoretical bases of the sliding mode variable structure control were introduced, and the stability proof was presented. Switching function of the system has been deduced, sliding mode voltage controller model has been established, and the output of the outer voltage loop is the instruction of the inner current loop. Affine nonlinear model of two input two output equations on d-q axis for current has been established its meeting conditions of exact linearization were proved. In order to improve the anti-jamming capability of the system, a variable structure control was added in the current controller, the control law was deduced. The dual-loop control with sliding mode control in outer voltage loop and linearization variable structure control in inner current loop was proposed. Simulation results demonstrate the effectiveness of the proposed control strategy even during the dc reference voltage and system load variation.

  18. Forward and reverse control system for induction motors

    DOEpatents

    Wright, J.T.

    1987-09-15

    A control system for controlling the direction of rotation of a rotor of an induction motor includes an array of five triacs with one of the triacs applying a current of fixed phase to the windings of the rotor and four of the triacs being switchable to apply either hot ac current or return ac current to the stator windings so as to reverse the phase of current in the stator relative to that of the rotor and thereby reverse the direction of rotation of the rotor. Switching current phase in the stator is accomplished by operating the gates of pairs of the triacs so as to connect either hot ac current or return ac current to the input winding of the stator. 1 fig.

  19. A linearly controlled direct-current power source for high-current inductive loads in a magnetic suspension wind tunnel

    NASA Technical Reports Server (NTRS)

    Tripp, John S.; Daniels, Taumi S.

    1990-01-01

    The NASA Langley 6 inch magnetic suspension and balance system (MSBS) requires an independently controlled bidirectional DC power source for each of six positioning electromagnets. These electromagnets provide five-degree-of-freedom control over a suspended aerodynamic test model. Existing power equipment, which employs resistance coupled thyratron controlled rectifiers as well as AC to DC motor generator converters, is obsolete, inefficient, and unreliable. A replacement six phase bidirectional controlled bridge rectifier is proposed, which employs power MOSFET switches sequenced by hybrid analog/digital circuits. Full load efficiency is 80 percent compared to 25 percent for the resistance coupled thyratron system. Current feedback provides high control linearity, adjustable current limiting, and current overload protection. A quenching circuit suppresses inductive voltage impulses. It is shown that 20 kHz interference from positioning magnet power into MSBS electromagnetic model position sensors results predominantly from capacitively coupled electric fields. Hence, proper shielding and grounding techniques are necessary. Inductively coupled magnetic interference is negligible.

  20. A new mathematical model and control of a three-phase AC-DC voltage source converter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blasko, V.; Kaura, V.

    1997-01-01

    A new mathematical model of the power circuit of a three-phase voltage source converter (VSC) was developed in the stationary and synchronous reference frames. The mathematical model was then used to analyze and synthesize the voltage and current control loops for the VSC. Analytical expressions were derived for calculating the gains and time constants of the current and voltage regulators. The mathematical model was used to control a 140-kW regenerative VSC. The synchronous reference frame model was used to define feedforward signals in the current regulators to eliminate the cross coupling between the d and q phases. It allowed themore » reduction of the current control loop to first-order plants and improved their tracking capability. The bandwidths of the current and voltage-control loops were found to be approximately 20 and 60 times (respectively) smaller than the sampling frequency. All control algorithms were implemented in a digital-signal processor. All results of the analysis were experimentally verified.« less

  1. Physics-based Control-oriented Modeling of the Current Profile Evolution in NSTX-Upgrade

    NASA Astrophysics Data System (ADS)

    Ilhan, Zeki; Barton, Justin; Shi, Wenyu; Schuster, Eugenio; Gates, David; Gerhardt, Stefan; Kolemen, Egemen; Menard, Jonathan

    2013-10-01

    The operational goals for the NSTX-Upgrade device include non-inductive sustainment of high- β plasmas, realization of the high performance equilibrium scenarios with neutral beam heating, and achievement of longer pulse durations. Active feedback control of the current profile is proposed to enable these goals. Motivated by the coupled, nonlinear, multivariable, distributed-parameter plasma dynamics, the first step towards feedback control design is the development of a physics-based, control-oriented model for the current profile evolution in response to non-inductive current drives and heating systems. For this purpose, the nonlinear magnetic-diffusion equation is coupled with empirical models for the electron density, electron temperature, and non-inductive current drives (neutral beams). The resulting first-principles-driven, control-oriented model is tailored for NSTX-U based on the PTRANSP predictions. Main objectives and possible challenges associated with the use of the developed model for control design are discussed. This work was supported by PPPL.

  2. Power controller 28Vdc load switching (N. O. SPST). Final report, 31 August 1977-21 January 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMackin, J.B.

    1980-01-21

    A solid state power controller has been designed in four ratings to switch 28Vdc power to selected loads upon remote command. The four ratings trip out at currents of 10, 5, 2 and 1/2 amps. The design allows for wide variations in load and supply voltage and will not trip out on short load transients of up to 1000% of rated load current. In case of failure of the controller circuitry, an internal fuse protects the load from excessive current. The control current which operates the controller also provides a sensing function so that the state of the controller canmore » be determined remotely. The controllers are designed to operate over a case temperature range of -54 C to 120 C. A quantity of 100 units have been fabricated, tested, and supplied to the Navy.« less

  3. Precision control of multiple quantum cascade lasers for calibration systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taubman, Matthew S., E-mail: Matthew.Taubman@pnnl.gov; Myers, Tanya L.; Pratt, Richard M.

    We present a precision, 1-A, digitally interfaced current controller for quantum cascade lasers, with demonstrated temperature coefficients for continuous and 40-kHz full-depth square-wave modulated operation, of 1–2 ppm/ °C and 15 ppm/ °C, respectively. High precision digital to analog converters (DACs) together with an ultra-precision voltage reference produce highly stable, precision voltages, which are selected by a multiplexer (MUX) chip to set output currents via a linear current regulator. The controller is operated in conjunction with a power multiplexing unit, allowing one of three lasers to be driven by the controller, while ensuring protection of controller and all lasers during operation, standby,more » and switching. Simple ASCII commands sent over a USB connection to a microprocessor located in the current controller operate both the controller (via the DACs and MUX chip) and the power multiplexer.« less

  4. Precision Control of Multiple Quantum Cascade Lasers for Calibration Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taubman, Matthew S.; Myers, Tanya L.; Pratt, Richard M.

    We present a precision, digitally interfaced current controller for quantum cascade lasers, with demonstrated DC and modulated temperature coefficients of 1- 2 ppm/ºC and 15 ppm/ºC respectively. High linearity digital to analog converters (DACs) together with an ultra-precision voltage reference, produce highly stable, precision voltages. These are in turn selected by a low charge-injection multiplexer (MUX) chip, which are then used to set output currents via a linear current regulator. The controller is operated in conjunction with a power multiplexing unit, allowing one of three lasers to be driven by the controller while ensuring protection of controller and all lasersmore » during operation, standby and switching. Simple ASCII commands sent over a USB connection to a microprocessor located in the current controller operate both the controller (via the DACs and MUX chip) and the power multiplexer.« less

  5. Model-based Optimization and Feedback Control of the Current Density Profile Evolution in NSTX-U

    NASA Astrophysics Data System (ADS)

    Ilhan, Zeki Okan

    Nuclear fusion research is a highly challenging, multidisciplinary field seeking contributions from both plasma physics and multiple engineering areas. As an application of plasma control engineering, this dissertation mainly explores methods to control the current density profile evolution within the National Spherical Torus eXperiment-Upgrade (NSTX-U), which is a substantial upgrade based on the NSTX device, which is located in Princeton Plasma Physics Laboratory (PPPL), Princeton, NJ. Active control of the toroidal current density profile is among those plasma control milestones that the NSTX-U program must achieve to realize its next-step operational goals, which are characterized by high-performance, long-pulse, MHD-stable plasma operation with neutral beam heating. Therefore, the aim of this work is to develop model-based, feedforward and feedback controllers that can enable time regulation of the current density profile in NSTX-U by actuating the total plasma current, electron density, and the powers of the individual neutral beam injectors. Motivated by the coupled, nonlinear, multivariable, distributed-parameter plasma dynamics, the first step towards control design is the development of a physics-based, control-oriented model for the current profile evolution in NSTX-U in response to non-inductive current drives and heating systems. Numerical simulations of the proposed control-oriented model show qualitative agreement with the high-fidelity physics code TRANSP. The next step is to utilize the proposed control-oriented model to design an open-loop actuator trajectory optimizer. Given a desired operating state, the optimizer produces the actuator trajectories that can steer the plasma to such state. The objective of the feedforward control design is to provide a more systematic approach to advanced scenario planning in NSTX-U since the development of such scenarios is conventionally carried out experimentally by modifying the tokamak's actuator trajectories and analyzing the resulting plasma evolution. Finally, the proposed control-oriented model is embedded in feedback control schemes based on optimal control and Model Predictive Control (MPC) approaches. Integrators are added to the standard Linear Quadratic Gaussian (LQG) and MPC formulations to provide robustness against various modeling uncertainties and external disturbances. The effectiveness of the proposed feedback controllers in regulating the current density profile in NSTX-U is demonstrated in closed-loop nonlinear simulations. Moreover, the optimal feedback control algorithm has been implemented successfully in closed-loop control simulations within TRANSP through the recently developed Expert routine. (Abstract shortened by ProQuest.).

  6. Comparative study of reference currents and DC bus voltage control for Three-Phase Four-Wire Four-Leg SAPF to compensate harmonics and reactive power with 3D SVM.

    PubMed

    Chebabhi, A; Fellah, M K; Kessal, A; Benkhoris, M F

    2015-07-01

    In this paper the performances of three reference currents and DC bus voltage control techniques for Three-Phase Four-Wire Four-Leg SAPF are compared for balanced and unbalanced load conditions. The main goals are to minimize the harmonics, reduce the magnitude of neutral current, eliminate the zero-sequence current components caused by single-phase nonlinear loads and compensate the reactive power, and on the other hand improve performances such as robustness, stabilization, trajectory pursuit, and reduce time response. The three techniques are analyzed mathematically and simulation results are compared. The techniques considered for comparative study are the PI Control, Sliding Mode Control and the Backstepping Control. Synchronous reference frame theory (SRF) in the dqo-axes is used to generate the reference currents, of the inverter. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  7. Two-motor direct drive control for elevation axis of telescope

    NASA Astrophysics Data System (ADS)

    Tang, T.; Tan, Y.; Ren, G.

    2014-07-01

    Two-motor application has become a very attractive filed in important field which high performance is permitted to achieve of position, speed, and acceleration. In the elevation axis of telescope control system, two-motor direct drive is proposed to enhance the high performance of tracking control system. Although there are several dominant strengths such as low size of motors and high torsional structural dynamics, the synchronization control of two motors is a very difficult and important. In this paper, a multi-loop control technique base master-slave current control is used to synchronize two motors, including current control loop, speed control loop and position control loop. First, the direct drive function of two motors is modeled. Compared of single motor direct control system, the resonance frequency of two motor control systems is same; while the anti-resonance frequency of two motors control system is 1.414 times than those of sing motor system. Because of rigid coupling for direct drive, the speed of two motor of the system is same, and the synchronization of torque for motors is critical. The current master-slave control technique is effective to synchronize the torque, which the current loop of the master motors is tracked the other slave motor. The speed feedback into the input of current loop of the master motors. The experiments test the performance of the two motors drive system. The random tracking error is 0.0119" for the line trajectory of 0.01°/s.

  8. Overload protection system for power inverter

    NASA Technical Reports Server (NTRS)

    Nagano, S. (Inventor)

    1977-01-01

    An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

  9. Particle-in-cell simulations of electron beam control using an inductive current divider

    DOE PAGES

    Swanekamp, S. B.; Angus, J. R.; Cooperstein, G.; ...

    2015-11-18

    Kinetic, time-dependent, electromagnetic, particle-in-cell simulations of the inductive current divider are presented. The inductive current divider is a passive method for controlling the trajectory of an intense, hollow electron beam using a vacuum structure that inductively splits the beam’s return current. The current divider concept was proposed and studied theoretically in a previous publication [Phys. Plasmas 22, 023107 (2015)] A central post carries a portion of the return current (I 1) while the outer conductor carries the remainder (I 2) with the injected beam current given by I b=I 1+I 2. The simulations are in agreement with the theory whichmore » predicts that the total force on the beam trajectory is proportional to (I 2-I 1) and the force on the beam envelope is proportional to I b. For a fixed central post, the beam trajectory is controlled by varying the outer conductor radius which changes the inductance in the return-current path. The simulations show that the beam emittance is approximately constant as the beam propagates through the current divider to the target. As a result, independent control over both the current density and the beam angle at the target is possible by choosing the appropriate return-current geometry.« less

  10. Hybrid zero-voltage switching (ZVS) control for power inverters

    DOEpatents

    Amirahmadi, Ahmadreza; Hu, Haibing; Batarseh, Issa

    2016-11-01

    A power inverter combination includes a half-bridge power inverter including first and second semiconductor power switches receiving input power having an intermediate node therebetween providing an inductor current through an inductor. A controller includes input comparison circuitry receiving the inductor current having outputs coupled to first inputs of pulse width modulation (PWM) generation circuitry, and a predictive control block having an output coupled to second inputs of the PWM generation circuitry. The predictive control block is coupled to receive a measure of Vin and an output voltage at a grid connection point. A memory stores a current control algorithm configured for resetting a PWM period for a switching signal applied to control nodes of the first and second power switch whenever the inductor current reaches a predetermined upper limit or a predetermined lower limit.

  11. Non-linear control of the output stage of a solar microinverter

    NASA Astrophysics Data System (ADS)

    Lopez-Santos, Oswaldo; Garcia, Germain; Martinez-Salamero, Luis; Avila-Martinez, Juan C.; Seguier, Lionel

    2017-01-01

    This paper presents a proposal to control the output stage of a two-stage solar microinverter to inject real power into the grid. The input stage of the microinverter is used to extract the maximum available power of a photovoltaic module enforcing a power source behavior in the DC-link to feed the output stage. The work here reported is devoted to control a grid-connected power source inverter with a high power quality level at the grid side ensuring the power balance of the microinverter regulating the voltage of the DC-link. The proposed control is composed of a sinusoidal current reference generator and a cascade type controller composed by a current tracking loop and a voltage regulation loop. The current reference is obtained using a synchronized generator based on phase locked loop (PLL) which gives the shape, the frequency and phase of the current signal. The amplitude of the reference is obtained from a simple controller regulating the DC-link voltage. The tracking of the current reference is accomplished by means of a first-order sliding mode control law. The solution takes advantage of the rapidity and inherent robustness of the sliding mode current controller allowing a robust behavior in the regulation of the DC-link using a simple linear controller. The analytical expression to determine the power quality indicators of the micro-inverter's output is theoretically solved giving expressions relating the converter parameters. The theoretical approach is validated using simulation and experimental results.

  12. Current harmonics elimination control method for six-phase PM synchronous motor drives.

    PubMed

    Yuan, Lei; Chen, Ming-liang; Shen, Jian-qing; Xiao, Fei

    2015-11-01

    To reduce the undesired 5th and 7th stator harmonic current in the six-phase permanent magnet synchronous motor (PMSM), an improved vector control algorithm was proposed based on vector space decomposition (VSD) transformation method, which can control the fundamental and harmonic subspace separately. To improve the traditional VSD technology, a novel synchronous rotating coordinate transformation matrix was presented in this paper, and only using the traditional PI controller in d-q subspace can meet the non-static difference adjustment, the controller parameter design method is given by employing internal model principle. Moreover, the current PI controller parallel with resonant controller is employed in x-y subspace to realize the specific 5th and 7th harmonic component compensation. In addition, a new six-phase SVPWM algorithm based on VSD transformation theory is also proposed. Simulation and experimental results verify the effectiveness of current decoupling vector controller. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  13. Electrically heated particulate filter regeneration methods and systems for hybrid vehicles

    DOEpatents

    Gonze, Eugene V.; Paratore, Jr., Michael J.

    2010-10-12

    A control system for controlling regeneration of a particulate filter for a hybrid vehicle is provided. The system generally includes a regeneration module that controls current to the particulate filter to initiate regeneration. An engine control module controls operation of an engine of the hybrid vehicle based on the control of the current to the particulate filter.

  14. Impact of village-based health education of tobacco control on the current smoking rate in Chinese rural areas.

    PubMed

    Wang, Jian-miao; Xiong, Wei-ning; Xie, Jun-gang; Liu, Xian-sheng; Zhao, Jian-ping; Zhang, Zhen-xiang; Xu, Yong-jian

    2016-02-01

    The number of smokers in Chinese rural areas is more than 200 million, which is twice that in cities. It is very significant to carry out tobacco control interventions in rural areas. We performed this community intervention study to evaluate the efficacy of village-based health education of tobacco control on the male current smoking rate in rural areas. The population of this study was the males above 15 years old from 6 villages in rural areas. The villages were randomly assigned to intervention group or control group (3 villages in each group). Self-designed smoking questionnaire was applied. The intervention group received the village-based health education of tobacco control for one year. The primary outcome measurement was the male current smoking rate. In the baseline investigation, completed surveys were returned by 814 male residents from the control group and 831 male residents from the intervention group. The male current smoking rate in the control group and the intervention group was 61.2% and 58.5%, respectively, before intervention. There was no significant difference between these two groups (P>0.05). After one-year intervention, the current smoking rate in the intervention group (51.2%) was significantly lower than that in the control group (62.8%) (P<0.001). Our study suggested that the village-based health education of tobacco control was effective in lowering the male current smoking rate in rural areas, which could be a suitable and feasible way for tobacco control in the Chinese rural areas.

  15. DC switching regulated power supply for driving an inductive load

    DOEpatents

    Dyer, George R.

    1986-01-01

    A power supply for driving an inductive load current from a dc power supply hrough a regulator circuit including a bridge arrangement of diodes and switching transistors controlled by a servo controller which regulates switching in response to the load current to maintain a selected load current. First and second opposite legs of the bridge are formed by first and second parallel-connected transistor arrays, respectively, while the third and fourth legs of the bridge are formed by appropriately connected first and second parallel connected diode arrays, respectively. The regulator may be operated in three "stages" or modes: (1) For current runup in the load, both first and second transistor switch arrays are turned "on" and current is supplied to the load through both transistor arrays. (2) When load current reaches the desired level, the first switch is turned "off", and load current "flywheels" through the second switch array and the fourth leg diode array connecting the second switch array in series with the load. Current is maintained by alternating between modes 1 and 2 at a suitable duty cycle and switching rate set by the controller. (3) Rapid current rundown is accomplished by turning both switch arrays "off", allowing load current to be dumped back into the source through the third and fourth diode arrays connecting the source in series opposition with the load to recover energy from the inductive load. The three operating states are controlled automatically by the controller.

  16. 42 CFR 400.310 - Display of currently valid OMB control numbers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of Information § 400.310 Display of currently valid OMB control numbers. Sections in 42 CFR that... 42 Public Health 2 2011-10-01 2011-10-01 false Display of currently valid OMB control numbers. 400....408 0938—0566 412.42 0938—0666 412.92 0938—0477 412.105 0938—0456 412.230, 412.232, 412.234, 412.236...

  17. 42 CFR 400.310 - Display of currently valid OMB control numbers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of Information § 400.310 Display of currently valid OMB control numbers. Sections in 42 CFR that... 42 Public Health 2 2010-10-01 2010-10-01 false Display of currently valid OMB control numbers. 400....408 0938—0566 412.42 0938—0666 412.92 0938—0477 412.105 0938—0456 412.230, 412.232, 412.234, 412.236...

  18. Systems and methods for commutating inductor current using a matrix converter

    DOEpatents

    Ransom, Ray M; Kajouke, Lateef A; Perisic, Milun

    2012-10-16

    Systems and methods are provided for delivering current using a matrix converter in a vehicle. An electrical system comprises an AC interface, a first conversion module coupled to the AC interface, an inductive element coupled between the AC interface and the first conversion module, and a control module coupled to the first conversion module. The control module is configured to operate the first conversion module in a bidirectional operating mode to commutate current bidirectionally. When a magnitude of the current through the inductive element is greater than a first threshold value, the control module operates the conversion module in a unidirectional operating mode, wherein current is commutated unidirectionally.

  19. Study on model current predictive control method of PV grid- connected inverters systems with voltage sag

    NASA Astrophysics Data System (ADS)

    Jin, N.; Yang, F.; Shang, S. Y.; Tao, T.; Liu, J. S.

    2016-08-01

    According to the limitations of the LVRT technology of traditional photovoltaic inverter existed, this paper proposes a low voltage ride through (LVRT) control method based on model current predictive control (MCPC). This method can effectively improve the photovoltaic inverter output characteristics and response speed. The MCPC method of photovoltaic grid-connected inverter designed, the sum of the absolute value of the predictive current and the given current error is adopted as the cost function with the model predictive control method. According to the MCPC, the optimal space voltage vector is selected. Photovoltaic inverter has achieved automatically switches of priority active or reactive power control of two control modes according to the different operating states, which effectively improve the inverter capability of LVRT. The simulation and experimental results proves that the proposed method is correct and effective.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yalong; Jones, Edward A.; Wang, Fred

    Arm inductor in a modular multilevel converter (MMC) is used to limit the circulating current and dc short circuit fault current. The circulating current in MMC is dominated by second-order harmonic, which can be largely reduced with circulating current suppressing control. By analyzing the mechanism of the circulating current suppressing control, it is found that the circulating current at switching frequency becomes the main harmonic when suppression control is implemented. Unlike the second-order harmonic that circulates only within the three phases, switching frequency harmonic also flows through the dc side and may further cause high-frequency dc voltage harmonic. This articlemore » develops the theoretical relationship between the arm inductance and switching frequency circulating current, which can be used to guide the arm inductance selection. The experimental results with a downscaled MMC prototype verify the existence of the switching frequency circulating current and its relationship with arm inductance.« less

  1. Influence of current or former smoking on asthma management and control.

    PubMed

    Boulet, Louis-Philippe; FitzGerald, J Mark; McIvor, R Andrew; Zimmerman, Sabrina; Chapman, Kenneth R

    2008-01-01

    In patients with asthma, smoking has been associated with accelerated decline in pulmonary function, poor disease control and reduced responsiveness to corticosteroids. To assess the influence of current and former smoking on self-reported asthma control and health care use in a large population of asthma patients. The present analysis was conducted following a telephone survey of adult Canadians aged 18 to 54 years who had physician-diagnosed asthma and a smoking history of less than 20 pack-years. Of 893 patients, 268 were former smokers and 108 were current smokers. Daytime and nighttime symptoms, absenteeism from work or school, emergency care use for asthma in the past year, and use of a short-acting bronchodilator without controller medication were reported more frequently by current smokers than nonsmokers and former smokers. Former smokers were not significantly different from nonsmokers with respect to most asthma outcomes. Current smokers with asthma show evidence of poorer asthma control and greater acute care needs than lifelong nonsmokers or former smokers. These observations stress the importance of smoking cessation to help achieve asthma control.

  2. Model Predictive Control of the Current Profile and the Internal Energy of DIII-D Plasmas

    NASA Astrophysics Data System (ADS)

    Lauret, M.; Wehner, W.; Schuster, E.

    2015-11-01

    For efficient and stable operation of tokamak plasmas it is important that the current density profile and the internal energy are jointly controlled by using the available heating and current-drive (H&CD) sources. The proposed approach is a version of nonlinear model predictive control in which the input set is restricted in size by the possible combinations of the H&CD on/off states. The controller uses real-time predictions over a receding-time horizon of both the current density profile (nonlinear partial differential equation) and the internal energy (nonlinear ordinary differential equation) evolutions. At every time instant the effect of every possible combination of H&CD sources on the current profile and internal energy is evaluated over the chosen time horizon. The combination that leads to the best result, which is assessed by a user-defined cost function, is then applied up until the next time instant. Simulations results based on a control-oriented transport code illustrate the effectiveness of the proposed control method. Supported by the US DOE under DE-FC02-04ER54698 & DE-SC0010661.

  3. An Improved Distributed Secondary Control Method for DC Microgrids With Enhanced Dynamic Current Sharing Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Panbao; Lu, Xiaonan; Yang, Xu

    This paper proposes an improved distributed secondary control scheme for dc microgrids (MGs), aiming at overcoming the drawbacks of conventional droop control method. The proposed secondary control scheme can remove the dc voltage deviation and improve the current sharing accuracy by using voltage-shifting and slope-adjusting approaches simultaneously. Meanwhile, the average value of droop coefficients is calculated, and then it is controlled by an additional controller included in the distributed secondary control layer to ensure that each droop coefficient converges at a reasonable value. Hence, by adjusting the droop coefficient, each participating converter has equal output impedance, and the accurate proportionalmore » load current sharing can be achieved with different line resistances. Furthermore, the current sharing performance in steady and transient states can be enhanced by using the proposed method. The effectiveness of the proposed method is verified by detailed experimental tests based on a 3 × 1 kW prototype with three interface converters.« less

  4. Preclinical assessment of abuse liability of biologics: In defense of current regulatory control policies.

    PubMed

    Gauvin, David V; Zimmermann, Zachary J; Baird, Theodore J

    2015-10-01

    Current regulatory policies of both the US Food and Drug Administration and Drug Enforcement Administration do not delineate automatic exceptions for biologics with respect to preclinical assessments for abuse liability of all new entities. As defined in current guidance documents and drug control policies, an exception may be given upon thorough review of available data, therapeutic target and in consultation with the Controlled Substances Staff within the Center for Drug Evaluation and Research of the FDA, but a blanket exception for all biological entities is not currently available. We review the abuse liability testing of four known biologics with definitive positive abuse liability signals in the three core abuse liability assays, self-administration, drug discrimination, and dependence potential described in the FDA draft guidance document. Interestingly, while all four examplars have positive abuse liability signals in all three assays, two of these biologics are controlled under the Comprehensive Drug Abuse and Control Act (CSA, 1970) and the other two are not currently controlled. Admittedly, these four biologics are small molecule entities. However, there is no reference to "molecular size" in the legally-binding statutory definition of biologics under the FD&C act or in the Controlled Substances Act. Neither of these drug control policy mandates have a bifurcated control status in which to make exceptions based solely on molecular size. With the current pharmaceutical focus on new technologies, such as "Trojan Horses", targeting the active transport of large molecule entities directly into the CNS, an argument to automatically exempt new molecular entities solely on molecular size is untenable. We argue that for the safety and health of general public the current regulatory control status be maintained until definitive criteria for exceptions can be identified and amended to both the FD&CA and CSA, if warranted. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. NLCC controller for SEPIC-based micro-wind energy conversion system

    NASA Astrophysics Data System (ADS)

    Justin Nayagam, Brintha Jane; Sathi, Rama Reddy; Olimuthu, Divya

    2017-04-01

    The growth of the power industry is gaining greater momentum as the usage of the non-conventional energy sources that include fuel, solar, and wind energies, increases. Wind energy conversion systems (WECSs) are gaining more popularity and are expected to be able to control the power at the output. This paper describes the current control (CC), non-linear carrier charge control (NLCCC), and fuzzy logic control (FLC) applied to the single-ended primary inductor converter (SEPIC)-based WECS. The current controller has an inherent overcurrent protection with better line noise rejection. The pulses for the switch of the SEPIC are obtained by comparing the current flowing through it with the virtual current reference. FLC is also investigated for the micro-wind energy conversion system (μWECS), since it improves the damping characteristics of WECS over a wide range of operating points. This cannot attain the unity power factor rectification. In this paper, NLCCC is proposed for high-power factor rectifier-based SEPIC in continuous conduction mode (CCM) for μWECS. The proposed converter provides an output voltage with low input current ripple due to the presence of the inductor at the input side. By comparing the signal proportional to the integral of switch current with a periodic non-linear carrier wave, the duty ratio of the converter switch is determined for the NLCC controller. By selecting the shape of the periodic non-linear carrier wave the input-line current can be made to follow the input-line voltage. This work employs a parabolic carrier waveform generator. The output voltage is regulated for changes in the wind speed. The results obtained prove the effectiveness of the NLCC controller in improving the power factor.

  6. PI and fuzzy logic controllers for shunt Active Power Filter--a report.

    PubMed

    P, Karuppanan; Mahapatra, Kamala Kanta

    2012-01-01

    This paper presents a shunt Active Power Filter (APF) for power quality improvements in terms of harmonics and reactive power compensation in the distribution network. The compensation process is based only on source current extraction that reduces the number of sensors as well as its complexity. A Proportional Integral (PI) or Fuzzy Logic Controller (FLC) is used to extract the required reference current from the distorted line-current, and this controls the DC-side capacitor voltage of the inverter. The shunt APF is implemented with PWM-current controlled Voltage Source Inverter (VSI) and the switching patterns are generated through a novel Adaptive-Fuzzy Hysteresis Current Controller (A-F-HCC). The proposed adaptive-fuzzy-HCC is compared with fixed-HCC and adaptive-HCC techniques and the superior features of this novel approach are established. The FLC based shunt APF system is validated through extensive simulation for diode-rectifier/R-L loads. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  7. Controlling heat and particle currents in nanodevices by quantum observation

    NASA Astrophysics Data System (ADS)

    Biele, Robert; Rodríguez-Rosario, César A.; Frauenheim, Thomas; Rubio, Angel

    2017-07-01

    We demonstrate that in a standard thermo-electric nanodevice the current and heat flows are not only dictated by the temperature and potential gradient, but also by the external action of a local quantum observer that controls the coherence of the device. Depending on how and where the observation takes place, the direction of heat and particle currents can be independently controlled. In fact, we show that the current and heat flow in a quantum material can go against the natural temperature and voltage gradients. Dynamical quantum observation offers new possibilities for the control of quantum transport far beyond classical thermal reservoirs. Through the concept of local projections, we illustrate how we can create and directionality control the injection of currents (electronic and heat) in nanodevices. This scheme provides novel strategies to construct quantum devices with application in thermoelectrics, spintronic injection, phononics, and sensing among others. In particular, highly efficient and selective spin injection might be achieved by local spin projection techniques.

  8. Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

    NASA Technical Reports Server (NTRS)

    Soltis, James V.

    1998-01-01

    The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

  9. Control of arc length during gas metal arc welding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madigan, R.B.; Quinn, T.P.

    1994-12-31

    An arc-length control system has been developed for gas metal arc welding (GMAW) under spray transfer welding conditions. The ability to monitor and control arc length during arc welding allows consistent weld characteristics to be maintained and therefore improves weld quality. Arc length control has only been implemented for gas tungsten arc welding (GTAW), where an automatic voltage control (AVC) unit adjusts torch-to-work distance. The system developed here compliments the voltage- and current-sensing techniques commonly used for control of GMAW. The system consists of an arc light intensity sensor (photodiode), a Hall-effect current sensor, a personal computer and software implementingmore » a data interpretation and control algorithms. Arc length was measured using both arc light and arc current signals. Welding current was adjusted to maintain constant arc length. A proportional-integral-derivative (PID) controller was used. Gains were automatically selected based on the desired welding conditions. In performance evaluation welds, arc length varied from 2.5 to 6.5 mm while welding up a sloped workpiece (ramp in CTWD) without the control. Arc length was maintained within 1 mm of the desired (5 mm ) with the control.« less

  10. Rotor Current Control of DFIG for Improving Fault Ride - Through Using a Novel Sliding Mode Control Approach

    NASA Astrophysics Data System (ADS)

    Cai, Guowei; Liu, Cheng; Yang, Deyou

    2013-11-01

    The doubly fed induction generators (DFIG) have been recognized as the dominant technology used in wind power generation systems with the rapid development of wind power. However, continuous operation of DFIG may cause a serious wind turbine generators tripping accident, due to destructive over-current in the rotor winding which is caused by the power system fault or inefficient fault ride-through (FRT) strategy. A new rotor current control scheme in the rotor-side converter (RSC) ispresented to enhance FRT capacities of grid-connected DFIG. Due to the strongly nonlinear nature of DFIG and insensitive to DFIG parameter's variations, a novel sliding mode controller was designed. The controller combines extended state observer (ESO) with sliding model variable structure control theory. The simulation is carried out to verify the effectiveness of the proposed control approach under various types of grid disturbances. It is shown that the proposed controller provides enhanced transient features than the classic proportional-integral control. The proposed control method can effectively reduce over-current in the RSC, and the transient pulse value of electromagnetic torque is too large under power grid fault.

  11. Electrically heated particulate matter filter soot control system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonze, Eugene V.; Paratore, Jr., Michael J.; Bhatia, Garima

    A regeneration system includes a particulate matter (PM) filter with an upstream end for receiving exhaust gas and a downstream end. A control module determines a current soot loading level of the PM filter and compares the current soot loading level to a predetermined soot loading level. The control module permits regeneration of the PM filter when the current soot loading level is less than the predetermined soot loading level.

  12. Cascaded resonant bridge converters

    NASA Technical Reports Server (NTRS)

    Stuart, Thomas A. (Inventor)

    1989-01-01

    A converter for converting a low voltage direct current power source to a higher voltage, high frequency alternating current output for use in an electrical system where it is desired to use low weight cables and other circuit elements. The converter has a first stage series resonant (Schwarz) converter which converts the direct current power source to an alternating current by means of switching elements that are operated by a variable frequency voltage regulator, a transformer to step up the voltage of the alternating current, and a rectifier bridge to convert the alternating current to a direct current first stage output. The converter further has a second stage series resonant (Schwarz) converter which is connected in series to the first stage converter to receive its direct current output and convert it to a second stage high frequency alternating current output by means of switching elements that are operated by a fixed frequency oscillator. The voltage of the second stage output is controlled at a relatively constant value by controlling the first stage output voltage, which is accomplished by controlling the frequency of the first stage variable frequency voltage controller in response to second stage voltage. Fault tolerance in the event of a load short circuit is provided by making the operation of the first stage variable frequency voltage controller responsive to first and second stage current limiting devices. The second stage output is connected to a rectifier bridge whose output is connected to the input of the second stage to provide good regulation of output voltage wave form at low system loads.

  13. Circulating Current Suppressing Control’s Impact on Arm Inductance Selection for Modular Multilevel Converter

    DOE PAGES

    Li, Yalong; Jones, Edward A.; Wang, Fred

    2016-10-13

    Arm inductor in a modular multilevel converter (MMC) is used to limit the circulating current and dc short circuit fault current. The circulating current in MMC is dominated by second-order harmonic, which can be largely reduced with circulating current suppressing control. By analyzing the mechanism of the circulating current suppressing control, it is found that the circulating current at switching frequency becomes the main harmonic when suppression control is implemented. Unlike the second-order harmonic that circulates only within the three phases, switching frequency harmonic also flows through the dc side and may further cause high-frequency dc voltage harmonic. This articlemore » develops the theoretical relationship between the arm inductance and switching frequency circulating current, which can be used to guide the arm inductance selection. The experimental results with a downscaled MMC prototype verify the existence of the switching frequency circulating current and its relationship with arm inductance.« less

  14. Bi-directional power control system for voltage converter

    DOEpatents

    Garrigan, Neil Richard; King, Robert Dean; Schwartz, James Edward

    1999-01-01

    A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

  15. Bi-directional power control system for voltage converter

    DOEpatents

    Garrigan, N.R.; King, R.D.; Schwartz, J.E.

    1999-05-11

    A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals. 10 figs.

  16. RF lockout circuit for electronic locking system

    NASA Astrophysics Data System (ADS)

    Becker, Earl M., Jr.; Miller, Allen

    1991-02-01

    An electronics lockout circuit was invented that includes an antenna adapted to receive radio frequency signals from a transmitter, and a radio frequency detector circuit which converts the radio frequency signals into a first direct current voltage indicative of the relative strength of the field resulting from the radio frequency signals. The first direct current voltage is supplied to a trigger circuit which compares this direct current voltage to an adjustable direct current reference voltage. This provides a second direct current voltage at the output whenever the amplitude of the first direct current voltage exceeds the amplitude of the reference voltage provided by the comparator circuit. This is supplied to a disconnect relay circuit which, upon receiving a signal from the electronic control unit of an electronic combination lock during the time period at which the second direct current voltage is present, isolates the door strike coil of a security door from the electronic control unit. This prevents signals falsely generated by the electronic control unit because of radio frequency signals in the vicinity of the electronic control unit energizing the door strike coil and accidentally opening a security door.

  17. Insulin sensitivity in relation to fat distribution and plasma adipocytokines among abusers of anabolic androgenic steroids.

    PubMed

    Rasmussen, Jon Jarløv; Schou, Morten; Selmer, Christian; Johansen, Marie Louise; Gustafsson, Finn; Frystyk, Jan; Dela, Flemming; Faber, Jens; Kistorp, Caroline

    2017-09-01

    Abuse of anabolic androgenic steroids (AAS) is prevalent among young men, but information regarding effects on insulin sensitivity and fat distribution is limited. The objective was to investigate insulin sensitivity in relation to fat distribution and adipocytokines among current and former AAS abusers compared with controls. Cross-sectional study among men involved in recreational strength training. Current and former AAS abusers (n=37 and n=33) and controls (n=30) volunteered from the community. We assessed insulin sensitivity by Matsuda index (oral glucose tolerance test). Using overnight fasting blood samples, adiponectin and leptin were measured. Body composition and fat distribution, including visceral adipose tissue (VAT), were assessed by dual energy X-ray absorptiometry. Current and former AAS abusers displayed lower Matsuda index than controls (%-difference (95%CI) from controls, -26% (-45; -1) and -39% (-55; -18)). Testosterone was markedly higher among current AAS abusers and subnormal among former AAS abusers compared with controls. Current AAS abusers displayed higher mean VAT than controls (388 (17) vs 293 (12) cm 3 , P<.001) whereas body fat %, adiponectin and leptin concentrations were lower. In contrast, former AAS abusers showed highest leptin concentrations and body fat %. Multivariate linear regressions identified VAT as independent predictor of lower Matsuda index among current AAS abusers compared with controls; while body fat % independently predicted lower Matsuda index among former AAS abusers. Both current and former AAS abusers displayed lower insulin sensitivity which could be mediated by higher VAT and total body fat %, respectively. © 2017 John Wiley & Sons Ltd.

  18. Battery charging and discharging research based on the interactive technology of smart grid and electric vehicle

    NASA Astrophysics Data System (ADS)

    Zhang, Mingyang

    2018-06-01

    To further study the bidirectional flow problem of V2G (Vehicle to Grid) charge and discharge motor, the mathematical model of AC/DC converter and bi-directional DC/DC converter was established. Then, lithium battery was chosen as the battery of electric vehicle and its mathematical model was established. In order to improve the service life of lithium battery, bidirectional DC/DC converter adopted constant current and constant voltage control strategy. In the initial stage of charging, constant current charging was adopted with current single closed loop control. After reaching a certain value, voltage was switched to constant voltage charging controlled by voltage and current. Subsequently, the V2G system simulation model was built in MATLAB/Simulink. The simulation results verified the correctness of the control strategy and showed that when charging, constant current and constant voltage charging was achieved, the grid side voltage and current were in the same phase, and the power factor was about 1. When discharging, the constant current discharge was applied, and the grid voltage and current phase difference was r. To sum up, the simulation results are correct and helpful.

  19. Upgrade of the gas flow control system of the resistive current leads of the LHC inner triplet magnets: Simulation and experimental validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perin, A.; Casas-Cubillos, J.; Pezzetti, M.

    2014-01-29

    The 600 A and 120 A circuits of the inner triplet magnets of the Large Hadron Collider are powered by resistive gas cooled current leads. The current solution for controlling the gas flow of these leads has shown severe operability limitations. In order to allow a more precise and more reliable control of the cooling gas flow, new flowmeters will be installed during the first long shutdown of the LHC. Because of the high level of radiation in the area next to the current leads, the flowmeters will be installed in shielded areas located up to 50 m away frommore » the current leads. The control valves being located next to the current leads, this configuration leads to long piping between the valves and the flowmeters. In order to determine its dynamic behaviour, the proposed system was simulated with a numerical model and validated with experimental measurements performed on a dedicated test bench.« less

  20. Low exhaust temperature electrically heated particulate matter filter system

    DOEpatents

    Gonze, Eugene V [Pinckney, MI; Paratore, Jr., Michael J.; Bhatia, Garima [Bangalore, IN

    2012-02-14

    A system includes a particulate matter (PM) filter, a sensor, a heating element, and a control module. The PM filter includes with an upstream end that receives exhaust gas, a downstream end and multiple zones. The sensor detects a temperature of the exhaust gas. The control module controls current to the heating element to convection heat one of the zones and initiate a regeneration process. The control module selectively increases current to the heating element relative to a reference regeneration current level when the temperature is less than a predetermined temperature.

  1. Current developments in bovine mastitis treatment and control.

    PubMed

    Wager, L A; Linquist, W E; Hayes, G L; Britten, A M; Whitehead, R G; Webster, D E; Barnes, F D

    1978-01-01

    Mastitis in its complexity has managed to forestall all efforts of eradication in spite of years of research, antibiotics and practical control measures. This minisymposium will touch on seven topics current to treatment and control of this economically important disease.

  2. Current-controlled curvature of coated micromirrors

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Talghader, Joseph J.

    2003-06-01

    Precise control of micromirror curvature is critical in many optical microsystems. Micromirrors with current-controlled curvature are demonstrated. The working principle is that resistive heating changes the temperature of the micromirrors and thermal expansion induces a controlled curvature whose magnitude is determined by coating design. For example, for wide focal-length tuning, the radius of curvature of a gold-coated mirror was tuned from 2.5 to 8.2 mm over a current-induced temperature range from 22° to 72 °C. For fine focal-length tuning, the radius of curvature of a dielectric-coated (SiO2/Y2O3 λ/4 pairs) mirror was tuned from -0.68 to -0.64 mm over a current-induced temperature range from 22 to 84 °C. These results should be readily extendable to mirror flattening or real-time adaptive shape control.

  3. Control System for Bearingless Motor-generator

    NASA Technical Reports Server (NTRS)

    Kascak, Peter E. (Inventor); Jansen, Ralph H. (Inventor); Dever, Timothy P. (Inventor)

    2008-01-01

    A control system for an electromagnetic rotary drive for bearingless motor-generators comprises a winding configuration comprising a plurality of individual pole pairs through which phase current flows, each phase current producing both a lateral force and a torque. A motor-generator comprises a stator, a rotor supported for movement relative to the stator, and a control system. The motor-generator comprises a winding configuration supported by the stator. The winding configuration comprises at least three pole pairs through which phase current flows resulting in three three-phase systems. Each phase system has a first rotor reference frame axis current that produces a levitating force with no average torque and a second rotor reference frame axis current that produces torque.

  4. Control system for bearingless motor-generator

    NASA Technical Reports Server (NTRS)

    Jansen, Ralph H. (Inventor); Dever, Timothy P. (Inventor); Kascak, Peter E. (Inventor)

    2010-01-01

    A control system for an electromagnetic rotary drive for bearingless motor-generators comprises a winding configuration comprising a plurality of individual pole pairs through which phase current flows, each phase current producing both a lateral force and a torque. A motor-generator comprises a stator, a rotor supported for movement relative to the stator, and a control system. The motor-generator comprises a winding configuration supported by the stator. The winding configuration comprises at least three pole pairs through which phase current flows resulting in three three-phase systems. Each phase system has a first rotor reference frame axis current that produces a levitating force with no average torque and a second rotor reference frame axis current that produces torque.

  5. Stability Analysis of Distributed Engine Control Systems Under Communication Packet Drop (Postprint)

    DTIC Science & Technology

    2008-07-01

    use, modify, reproduce, release, perform, display, or disclose the work. 14. ABSTRACT Currently, Full Authority Digital Engine Control ( FADEC ...based on a centralized architecture framework is being widely used for gas turbine engine control. However, current FADEC is not able to meet the...system (DEC). FADEC based on Distributed Control Systems (DCS) offers modularity, improved control systems prognostics and fault tolerance along with

  6. Higher Education Financial Statistics, 1981-82.

    ERIC Educational Resources Information Center

    Hottinger, Gerald W.

    Statistical data on Pennsylvania higher education finance for 1981-1982 are presented. Tables provide the following information: current-funds revenues by institutional control, 1972-1973 through 1981-1982; percent of current-funds revenues by source, 1972-1973 through 1981-1982; current-funds expenditures by institutional control, 1972-1973…

  7. 40 CFR 434.52 - Effluent limitations quidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... technology currently available (BPT). 434.52 Section 434.52 Protection of Environment ENVIRONMENTAL... practicable control technology currently available (BPT). (a) Reclamation areas. The limitations in this... this subsection after application of the best practicable control technology currently available: BPT...

  8. 40 CFR 440.52 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available (BPT). 440.52 Section 440.52 Protection of Environment ENVIRONMENTAL... reduction attainable by the application of the best practicable control technology currently available (BPT... effluent reduction attainable after application of the best practicable control technology currently...

  9. 40 CFR 434.52 - Effluent limitations quidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... technology currently available (BPT). 434.52 Section 434.52 Protection of Environment ENVIRONMENTAL... practicable control technology currently available (BPT). (a) Reclamation areas. The limitations in this... this subsection after application of the best practicable control technology currently available: BPT...

  10. 40 CFR 434.52 - Effluent limitations quidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... technology currently available (BPT). 434.52 Section 434.52 Protection of Environment ENVIRONMENTAL... practicable control technology currently available (BPT). (a) Reclamation areas. The limitations in this... this subsection after application of the best practicable control technology currently available: BPT...

  11. 40 CFR 436.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... technology currently available. 436.32 Section 436.32 Protection of Environment ENVIRONMENTAL PROTECTION... effluent reduction attainable by the application of the best practicable control technology currently... of the best practicable control technology currently available (BPT): (1) Discharges of process...

  12. 40 CFR 434.52 - Effluent limitations quidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... technology currently available (BPT). 434.52 Section 434.52 Protection of Environment ENVIRONMENTAL... practicable control technology currently available (BPT). (a) Reclamation areas. The limitations in this... this subsection after application of the best practicable control technology currently available: BPT...

  13. 40 CFR 434.52 - Effluent limitations quidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available (BPT). 434.52 Section 434.52 Protection of Environment ENVIRONMENTAL... practicable control technology currently available (BPT). (a) Reclamation areas. The limitations in this... this subsection after application of the best practicable control technology currently available: BPT...

  14. 40 CFR 440.52 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... technology currently available (BPT). 440.52 Section 440.52 Protection of Environment ENVIRONMENTAL... reduction attainable by the application of the best practicable control technology currently available (BPT... effluent reduction attainable after application of the best practicable control technology currently...

  15. 40 CFR 436.22 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available. 436.22 Section 436.22 Protection of Environment ENVIRONMENTAL PROTECTION... reduction attainable by the application of the best practicable control technology currently available. (a... best practicable control technology currently available (BPT): (1) Discharges of process generated...

  16. 40 CFR 436.22 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... technology currently available. 436.22 Section 436.22 Protection of Environment ENVIRONMENTAL PROTECTION... reduction attainable by the application of the best practicable control technology currently available. (a... best practicable control technology currently available (BPT): (1) Discharges of process generated...

  17. Digital control of a direct current converter for a hybrid vehicle

    NASA Astrophysics Data System (ADS)

    Hernandez, Juan Manuel

    The nonlinear feedback loops permitting the large signal control of pulse width modulators in direct current converters are discussed. A digital feedback loop on a converter controlling the coupling of a direct current machine is described. It is used in the propulsion of a hybrid vehicle (thermal-electric) with regenerative braking. The protection of the power switches is also studied. An active protection of the MOST bipolar transistor association is proposed.

  18. Large-current-controllable carbon nanotube field-effect transistor in electrolyte solution

    NASA Astrophysics Data System (ADS)

    Myodo, Miho; Inaba, Masafumi; Ohara, Kazuyoshi; Kato, Ryogo; Kobayashi, Mikinori; Hirano, Yu; Suzuki, Kazuma; Kawarada, Hiroshi

    2015-05-01

    Large-current-controllable carbon nanotube field-effect transistors (CNT-FETs) were fabricated with mm-long CNT sheets. The sheets, synthesized by remote-plasma-enhanced CVD, contained both single- and double-walled CNTs. Titanium was deposited on the sheet as source and drain electrodes, and an electrolyte solution was used as a gate electrode (solution gate) to apply a gate voltage to the CNTs through electric double layers formed around the CNTs. The drain current came to be well modulated as electrolyte solution penetrated into the sheets, and one of the solution gate CNT-FETs was able to control a large current of over 2.5 A. In addition, we determined the transconductance parameter per tube and compared it with values for other CNT-FETs. The potential of CNT sheets for applications requiring the control of large current is exhibited in this study.

  19. Constant voltage and constant current control implementation for electric vehicles (evs) wireless charger

    NASA Astrophysics Data System (ADS)

    Tampubolon, Marojahan; Pamungkas, Laskar; Hsieh, Yao Ching; Chiu, Huang Jen

    2018-04-01

    This paper presents the implementation of Constant Voltage (CV) and Constant Current (CC) control for a wireless charger system. A battery charging system needs these control modes to ensure the safety of the battery and the effectiveness of the charging system. Here, the wireless charger system does not employ any post-regulator stage to control the output voltage and output current of the charger. But, it uses a variable frequency control incorporated with a conventional PI control. As a result, the size and the weight of the system are reduced. This paper discusses the brief review of the SS-WPT, control strategy and implementation of the CV and CC control. Experimental hardware with 2kW output power has been performed and tested. The results show that the proposed CV and CC control method works well with the system.

  20. Nondissipative optimum charge regulator

    NASA Technical Reports Server (NTRS)

    Rosen, R.; Vitebsky, J. N.

    1970-01-01

    Optimum charge regulator provides constant level charge/discharge control of storage batteries. Basic power transfer and control is performed by solar panel coupled to battery through power switching circuit. Optimum controller senses battery current and modifies duty cycle of switching circuit to maximize current available to battery.

  1. The control of the upstream movement of fish with pulsated direct current

    USGS Publications Warehouse

    McLain, Alberton L.

    1957-01-01

    In the Silver River, 78,648 fish comprising 21 species were taken from the trap of the direct-current diversion device. The total kill of fish moving upstream, including 289 sea lampreys, was 1,016, or 1.3 percent. This river had presented a serious problem in the operation of an alternating-current control device during previous seasons. In 1955, 85.5 percent of three important species of fish were killed at the control structure. During 1956, this mortality was reduced to 8.1 percent by the operation of the direct-current equipment.

  2. Brush head composition, wear profile, and cleaning efficacy: an assessment of three electric brush heads using in vitro methods.

    PubMed

    Kaiser, Eva; Meyners, Michael; Markgraf, Dirk; Stoerkel, Ulrich; von Koppenfels, Roxana; Adam, Ralf; Soukup, Martin; Wehrbein, Heinrich; Erbe, Christina

    2014-01-01

    The objective of this research was to evaluate a current store brand (SB) brush head for composition/physical characteristics, Wear Index (WI), and cleaning efficacy versus the previous SB brush head refill design (SB control) and the Oral-B Precision Clean brush head (positive control, PC). This research consisted of three parts: 1) Analytical analysis using Fourier Transform Infrared (FT-IR) spectrometry to evaluate the chemical composition of the current SB brush head bristles relative to the SB control. In addition, physical parameters such as bristle count and diameter were determined. 2) Wear Index (WI) investigation to determine the Wear Index scores of in vitro-aged brush heads at four weeks (one month) and 13 weeks (three months) by a trained investigator. To "age" the brush heads, a robot system was used as a new alternative in vitro method to simulate aging by consumer use. 3) Robot testing to determine the cleaning performance of in vitro-aged brush heads, comparing one month-aged current SB brush heads with the SB control (one and three months-aged) and the PC brush heads (three months-aged) in a standardized fashion. 1) FT-IR analysis revealed that the chemical composition of the current and control SB refill brush heads is identical. In terms of physical parameters, the current SB brush head has 12% more bristles and a slightly oval brush head compared to the round brush head of the SB control. 2) Wear Index analysis showed there was no difference in the one month-aged current SB brush head versus the one month-aged SB control (1.67 vs. 1.50, p = 0.65) or versus the three months-aged PC brush head (1.67 vs. 1.50, p = 0.65). The one month-aged current SB brush head demonstrated statistically significantly less wear than the three months-aged SB control (1.67 vs. 2.67, p = 0.01). 3) Analysis of cleaning efficacy shows that the one month-aged current SB brush head had improved cleaning performance over the one month-aged SB control brush head (p < 0.05), despite no statistically significant difference in wear. Both the one month-aged current and control SB brush heads showed statistically significantly lower cleaning performance compared to the three months-aged PC brush heads (p < 0.01). While the current SB brush head showed improved cleaning over the SB control, it demonstrated significantly lower durability and cleaning in comparison to the PC brush head. Dental professionals should be aware of these differences, both in durability and in cleaning performance, when recommending brush heads to their patients.

  3. LSI logic for phase-control rectifiers

    NASA Technical Reports Server (NTRS)

    Dolland, C.

    1980-01-01

    Signals for controlling phase-controlled rectifier circuit are generated by combinatorial logic than can be implemented in large-scale integration (LSI). LSI circuit saves space, weight, and assembly time compared to previous controls that employ one-shot multivibrators, latches, and capacitors. LSI logic functions by sensing three phases of ac power source and by comparing actual currents with intended currents.

  4. Electrical energy consumption control apparatuses and electrical energy consumption control methods

    DOEpatents

    Hammerstrom, Donald J.

    2012-09-04

    Electrical energy consumption control apparatuses and electrical energy consumption control methods are described. According to one aspect, an electrical energy consumption control apparatus includes processing circuitry configured to receive a signal which is indicative of current of electrical energy which is consumed by a plurality of loads at a site, to compare the signal which is indicative of current of electrical energy which is consumed by the plurality of loads at the site with a desired substantially sinusoidal waveform of current of electrical energy which is received at the site from an electrical power system, and to use the comparison to control an amount of the electrical energy which is consumed by at least one of the loads of the site.

  5. 40 CFR 418.62 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available. 418.62 Section 418.62 Protection of Environment ENVIRONMENTAL PROTECTION... effluent reduction attainable by the application of the best practicable control technology currently... attainable by the application of the best practicable control technology currently available (BPT): There...

  6. 40 CFR 436.322 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available. 436.322 Section 436.322 Protection of Environment ENVIRONMENTAL PROTECTION... reduction attainable by the application of the best practicable control technology currently available... application of the best practicable control technology currently available (BPT): For operations not employing...

  7. 40 CFR 436.112 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available. 436.112 Section 436.112 Protection of Environment ENVIRONMENTAL PROTECTION... reduction attainable by the application of the best practicable control technology currently available... application of the best practicable control technology currently available (BPT): For operations not employing...

  8. 40 CFR 406.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available. 406.32 Section 406.32 Protection of Environment ENVIRONMENTAL PROTECTION... attainable by the application of the best practicable control technology currently available. Except as... of the best practicable control technology currently available (BPT): There shall be no discharge of...

  9. 40 CFR 406.82 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available. 406.82 Section 406.82 Protection of Environment ENVIRONMENTAL PROTECTION... by the application of the best practicable control technology currently available. Except as provided... of the best practicable control technology currently available (BPT): There shall be no discharge of...

  10. 40 CFR 436.102 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available. 436.102 Section 436.102 Protection of Environment ENVIRONMENTAL PROTECTION... reduction attainable by the application of the best practicable control technology currently available... application of the best practicable control technology currently available (BPT): For operations not employing...

  11. 40 CFR 406.72 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available. 406.72 Section 406.72 Protection of Environment ENVIRONMENTAL PROTECTION... by the application of the best practicable control technology currently available. Except as provided... of the best practicable control technology currently available (BPT): There shall be no discharge of...

  12. 40 CFR 424.52 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... practicable control technology currently available (BPT): There shall be no discharge of process waste water... technology currently available. 424.52 Section 424.52 Protection of Environment ENVIRONMENTAL PROTECTION... effluent reduction attainable by the application of the best practicable control technology currently...

  13. 40 CFR 406.52 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available. 406.52 Section 406.52 Protection of Environment ENVIRONMENTAL PROTECTION... attainable by the application of the best practicable control technology currently available. Except as... of the best practicable control technology currently available (BPT): There shall be no discharge of...

  14. 40 CFR 420.22 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available (BPT). 420.22 Section 420.22 Protection of Environment ENVIRONMENTAL... reduction attainable by the application of the best practicable control technology currently available (BPT... attainable by the application of the best practicable control technology currently available (BPT). (a...

  15. 40 CFR 436.182 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... technology currently available. 436.182 Section 436.182 Protection of Environment ENVIRONMENTAL PROTECTION... reduction attainable by the application of the best practicable control technology currently available. (a... practicable control technology currently available (BPT): (1) Discharges of process generated waste water and...

  16. 40 CFR 436.182 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available. 436.182 Section 436.182 Protection of Environment ENVIRONMENTAL PROTECTION... reduction attainable by the application of the best practicable control technology currently available. (a... practicable control technology currently available (BPT): (1) Discharges of process generated waste water and...

  17. Instantaneous Project Controls: Current Status, State of the Art, Benefits, and Strategies

    ERIC Educational Resources Information Center

    Abbaszadegan, Amin

    2016-01-01

    Despite advancements in construction and construction-related technology, capital project performance deviations, typically overruns, remain endemic within the capital projects industry. Currently, management is generally unaware of the current status of their projects, and thus monitoring and control of projects are not achieved effectively. In…

  18. Origin of negative resistance in anion migration controlled resistive memory

    NASA Astrophysics Data System (ADS)

    Banerjee, Writam; Wu, Facai; Hu, Yuan; Wu, Quantan; Wu, Zuheng; Liu, Qi; Liu, Ming

    2018-03-01

    Resistive random access memory (RRAM) is one of the most promising emerging nonvolatile technologies for the futuristic memory devices. Resistive switching behavior often shows negative resistance (NR), either voltage controlled or current controlled. In this work, the origin of a current compliance dependent voltage controlled NR effect during the resetting of anion migration based RRAM devices is discussed. The N-type voltage controlled NR is a high field driven phenomena. The current conduction within the range of a certain negative voltage is mostly dominated by space charge limited current. But with the higher negative voltage, a field induced tunneling effect is generated in the NR region. The voltage controlled NR is strongly dependent on the compliance current. The area independent behavior indicates the filamentary switching. The peak to valley ratio (PVR) is > 5. The variation of PVR as a function of the conduction band offset is achieved. Compared to other reported works, based on the PVR, it is possible to distinguish the RRAM types. Generally, due to the higher electric field effect on the metallic bridge during RESET, the electrochemical metallization type RRAM shows much higher PVR than the valance change type RRAM.

  19. Current Trends in Preservation Research and Development.

    ERIC Educational Resources Information Center

    Cunha, George Martin

    1990-01-01

    Overview of current trends in the preservation of library materials discusses collections conservation and management; climate control; insect and mold control; fire control; the effects of compact shelving; freezing and freeze-drying; space drying; alkaline paper; recycled paper; mass deacidification; and paper strengthening. (27 notes and…

  20. 40 CFR 420.03 - Alternative effluent limitations representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... technology currently available, best available technology economically achievable, best available demonstrated control technology, and best conventional pollutant control technology (the âwater bubbleâ). 420... of best practicable control technology currently available, best available technology economically...

  1. 40 CFR 420.03 - Alternative effluent limitations representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... technology currently available, best available technology economically achievable, best available demonstrated control technology, and best conventional pollutant control technology (the âwater bubbleâ). 420... of best practicable control technology currently available, best available technology economically...

  2. 40 CFR 420.03 - Alternative effluent limitations representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology currently available, best available technology economically achievable, best available demonstrated control technology, and best conventional pollutant control technology (the âwater bubbleâ). 420... of best practicable control technology currently available, best available technology economically...

  3. Unity power factor switching regulator

    NASA Technical Reports Server (NTRS)

    Rippel, Wally E. (Inventor)

    1983-01-01

    A single or multiphase boost chopper regulator operating with unity power factor, for use such as to charge a battery is comprised of a power section for converting single or multiphase line energy into recharge energy including a rectifier (10), one inductor (L.sub.1) and one chopper (Q.sub.1) for each chopper phase for presenting a load (battery) with a current output, and duty cycle control means (16) for each chopper to control the average inductor current over each period of the chopper, and a sensing and control section including means (20) for sensing at least one load parameter, means (22) for producing a current command signal as a function of said parameter, means (26) for producing a feedback signal as a function of said current command signal and the average rectifier voltage output over each period of the chopper, means (28) for sensing current through said inductor, means (18) for comparing said feedback signal with said sensed current to produce, in response to a difference, a control signal applied to the duty cycle control means, whereby the average inductor current is proportionate to the average rectifier voltage output over each period of the chopper, and instantaneous line current is thereby maintained proportionate to the instantaneous line voltage, thus achieving a unity power factor. The boost chopper is comprised of a plurality of converters connected in parallel and operated in staggered phase. For optimal harmonic suppression, the duty cycles of the switching converters are evenly spaced, and by negative coupling between pairs 180.degree. out-of-phase, peak currents through the switches can be reduced while reducing the inductor size and mass.

  4. Optimized Controller Design for a 12-Pulse Voltage Source Converter Based HVDC System

    NASA Astrophysics Data System (ADS)

    Agarwal, Ruchi; Singh, Sanjeev

    2017-12-01

    The paper proposes an optimized controller design scheme for power quality improvement in 12-pulse voltage source converter based high voltage direct current system. The proposed scheme is hybrid combination of golden section search and successive linear search method. The paper aims at reduction of current sensor and optimization of controller. The voltage and current controller parameters are selected for optimization due to its impact on power quality. The proposed algorithm for controller optimizes the objective function which is composed of current harmonic distortion, power factor, and DC voltage ripples. The detailed designs and modeling of the complete system are discussed and its simulation is carried out in MATLAB-Simulink environment. The obtained results are presented to demonstrate the effectiveness of the proposed scheme under different transient conditions such as load perturbation, non-linear load condition, voltage sag condition, and tapped load fault under one phase open condition at both points-of-common coupling.

  5. Planar maneuvering control of underwater snake robots using virtual holonomic constraints.

    PubMed

    Kohl, Anna M; Kelasidi, Eleni; Mohammadi, Alireza; Maggiore, Manfredi; Pettersen, Kristin Y

    2016-11-24

    This paper investigates the problem of planar maneuvering control for bio-inspired underwater snake robots that are exposed to unknown ocean currents. The control objective is to make a neutrally buoyant snake robot which is subject to hydrodynamic forces and ocean currents converge to a desired planar path and traverse the path with a desired velocity. The proposed feedback control strategy enforces virtual constraints which encode biologically inspired gaits on the snake robot configuration. The virtual constraints, parametrized by states of dynamic compensators, are used to regulate the orientation and forward speed of the snake robot. A two-state ocean current observer based on relative velocity sensors is proposed. It enables the robot to follow the path in the presence of unknown constant ocean currents. The efficacy of the proposed control algorithm for several biologically inspired gaits is verified both in simulations for different path geometries and in experiments.

  6. Towards Current Profile Control in ITER: Potential Approaches and Research Needs

    NASA Astrophysics Data System (ADS)

    Schuster, E.; Barton, J. E.; Wehner, W. P.

    2014-10-01

    Many challenging plasma control problems still need to be addressed in order for the ITER Plasma Control System (PCS) to be able to successfully achieve the ITER project goals. For instance, setting up a suitable toroidal current density profile is key for one possible advanced scenario characterized by noninductive sustainment of the plasma current and steady-state operation. The nonlinearity and high dimensionality exhibited by the plasma demand a model-based current-profile control synthesis procedure that can accommodate this complexity through embedding the known physics within the design. The development of a model capturing the dynamics of the plasma relevant for control design enables not only the design of feedback controllers for regulation or tracking but also the design of optimal feedforward controllers for a systematic model-based approach to scenario planning, the design of state estimators for a reliable real-time reconstruction of the plasma internal profiles based on limited and noisy diagnostics, and the development of a fast predictive simulation code for closed-loop performance evaluation before implementation. Progress towards control-oriented modeling of the current profile evolution and associated control design has been reported following both data-driven and first-principles-driven approaches. An overview of these two approaches will be provided, as well as a discussion on research needs associated with each one of the model applications described above. Supported by the US Department of Energy under DE-SC0001334 and DE-SC0010661.

  7. Current Controller for Multi-level Front-end Converter and Its Digital Implementation Considerations on Three-level Flying Capacitor Topology

    NASA Astrophysics Data System (ADS)

    Tekwani, P. N.; Shah, M. T.

    2017-10-01

    This paper presents behaviour analysis and digital implementation of current error space phasor based hysteresis controller applied to three-phase three-level flying capacitor converter as front-end topology. The controller is self-adaptive in nature, and takes the converter from three-level to two-level mode of operation and vice versa, following various trajectories of sector change with the change in reference dc-link voltage demanded by the load. It keeps current error space phasor within the prescribed hexagonal boundary. During the contingencies, the proposed controller takes the converter in over modulation mode to meet the load demand, and once the need is satisfied, controller brings back the converter in normal operating range. Simulation results are presented to validate behaviour of controller to meet the said contingencies. Unity power factor is assured by proposed controller with low current harmonic distortion satisfying limits prescribed in IEEE 519-2014. Proposed controller is implemented using TMS320LF2407 16-bit fixed-point digital signal processor. Detailed analysis of numerical format to avoid overflow of sensed variables in processor, and per-unit model implementation in software are discussed and hardware results are presented at various stages of signal conditioning to validate the experimental setup. Control logic for the generation of reference currents is implemented in TMS320LF2407A using assembly language and experimental results are also presented for the same.

  8. A new topology of fuel cell hybrid power source for efficient operation and high reliability

    NASA Astrophysics Data System (ADS)

    Bizon, Nicu

    2011-03-01

    This paper analyzes a new fuel cell Hybrid Power Source (HPS) topology having the feature to mitigate the current ripple of the fuel cell inverter system. In the operation of the inverter system that is grid connected or supplies AC motors in vehicle application, the current ripple normally appears at the DC port of the fuel cell HPS. Consequently, if mitigation measures are not applied, this ripple is back propagated to the fuel cell stack. Other features of the proposed fuel cell HPS are the Maximum Power Point (MPP) tracking, high reliability in operation under sharp power pulses and improved energy efficiency in high power applications. This topology uses an inverter system directly powered from the appropriate fuel cell stack and a controlled buck current source as low power source used for ripple mitigation. The low frequency ripple mitigation is based on active control. The anti-ripple current is injected in HPS output node and this has the LF power spectrum almost the same with the inverter ripple. Consequently, the fuel cell current ripple is mitigated by the designed active control. The ripple mitigation performances are evaluated by indicators that are defined to measure the mitigation ratio of the low frequency harmonics. In this paper it is shown that good performances are obtained by using the hysteretic current control, but better if a dedicated nonlinear controller is used. Two ways to design the nonlinear control law are proposed. First is based on simulation trials that help to draw the characteristic of ripple mitigation ratio vs. fuel cell current ripple. The second is based on Fuzzy Logic Controller (FLC). The ripple factor is up to 1% in both cases.

  9. A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

    NASA Astrophysics Data System (ADS)

    Shen, Yang-Wu; Ke, De-Ping; Sun, Yuan-Zhang; Daniel, Kirschen; Wang, Yi-Shen; Hu, Yuan-Chao

    2015-07-01

    A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator (DFIG) equipped with a superconducting magnetic energy storage (SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter (GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter (RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive (priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. Project supported by the National Natural Science Foundation of China (Grant No. 51307124) and the Major Program of the National Natural Science Foundation of China (Grant No. 51190105).

  10. Research on Parallel Three Phase PWM Converters base on RTDS

    NASA Astrophysics Data System (ADS)

    Xia, Yan; Zou, Jianxiao; Li, Kai; Liu, Jingbo; Tian, Jun

    2018-01-01

    Converters parallel operation can increase capacity of the system, but it may lead to potential zero-sequence circulating current, so the control of circulating current was an important goal in the design of parallel inverters. In this paper, the Real Time Digital Simulator (RTDS) is used to model the converters parallel system in real time and study the circulating current restraining. The equivalent model of two parallel converters and zero-sequence circulating current(ZSCC) were established and analyzed, then a strategy using variable zero vector control was proposed to suppress the circulating current. For two parallel modular converters, hardware-in-the-loop(HIL) study based on RTDS and practical experiment were implemented, results prove that the proposed control strategy is feasible and effective.

  11. Control of power to an inductively heated part

    DOEpatents

    Adkins, Douglas R.; Frost, Charles A.; Kahle, Philip M.; Kelley, J. Bruce; Stanton, Suzanne L.

    1997-01-01

    A process for induction hardening a part to a desired depth with an AC signal applied to the part from a closely coupled induction coil includes measuring the voltage of the AC signal at the coil and the current passing through the coil; and controlling the depth of hardening of the part from the measured voltage and current. The control system determines parameters of the part that are functions of applied voltage and current to the induction coil, and uses a neural network to control the application of the AC signal based on the detected functions for each part.

  12. Control of power to an inductively heated part

    DOEpatents

    Adkins, D.R.; Frost, C.A.; Kahle, P.M.; Kelley, J.B.; Stanton, S.L.

    1997-05-20

    A process for induction hardening a part to a desired depth with an AC signal applied to the part from a closely coupled induction coil includes measuring the voltage of the AC signal at the coil and the current passing through the coil; and controlling the depth of hardening of the part from the measured voltage and current. The control system determines parameters of the part that are functions of applied voltage and current to the induction coil, and uses a neural network to control the application of the AC signal based on the detected functions for each part. 6 figs.

  13. Current and Future Research in Active Control of Lightweight, Flexible Structures Using the X-56 Aircraft

    NASA Technical Reports Server (NTRS)

    Ryan, John J.; Bosworth, John T.; Burken, John J.; Suh, Peter M.

    2014-01-01

    The X-56 Multi-Utility Technology Testbed aircraft system is a versatile experimental research flight platform. The system was primarily designed to investigate active control of lightweight flexible structures, but is reconfigurable and capable of hosting a wide breadth of research. Current research includes flight experimentation of a Lockheed Martin designed active control flutter suppression system. Future research plans continue experimentation with alternative control systems, explore the use of novel sensor systems, and experiments with the use of novel control effectors. This paper describes the aircraft system, current research efforts designed around the system, and future planned research efforts that will be hosted on the aircraft system.

  14. Charge control microcomputer device for vehicle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morishita, M.; Kouge, S.

    1986-08-26

    A charge control microcomputer device is described for a vehicle, comprising: an AC generator driven by an engine for generating an output current, the generator having armature coils and a field coil; a battery charged by a rectified output of the generator and generating a terminal voltage; a voltage regulator for controlling a current flowing in the field coil, to control an output voltage of the generator to a predetermined value; an engine controlling microcomputer for receiving engine parameter data from the engine, to control the operation of the engine; a charge control microcomputer for processing input data including datamore » on at least one engine parameter output from the engine controlling microcomputer, and charge system data including at least one of battery terminal voltage data, generator voltage data and generator output current data, to provide a reference voltage for the voltage regulator.« less

  15. 78 FR 70528 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-26

    ... unless it displays a currently valid OMB control number. National Agricultural Statistics Service Title: Pesticide Protection Equipment. OMB Control Number: 0535-NEW. Summary of Collection: The primary objectives... currently valid OMB control number and the agency informs potential persons who are to respond to the...

  16. 77 FR 11480 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-27

    ... interstate commerce of any plant, plant product, biological control organism, noxious weed, means of... information unless the collection of information displays a currently valid OMB control number and the agency... required to respond to the collection of information unless it displays a currently valid OMB control...

  17. Bipolar square-wave current source for transient electromagnetic systems based on constant shutdown time

    NASA Astrophysics Data System (ADS)

    Wang, Shilong; Yin, Changchun; Lin, Jun; Yang, Yu; Hu, Xueyan

    2016-03-01

    Cooperative work of multiple magnetic transmitting sources is a new trend in the development of transient electromagnetic system. The key is the bipolar current waves shutdown, concurrently in the inductive load. In the past, it was difficult to use the constant clamping voltage technique to realize the synchronized shutdown of currents with different peak values. Based on clamping voltage technique, we introduce a new controlling method with constant shutdown time. We use the rising time to control shutdown time and use low voltage power source to control peak current. From the viewpoint of the circuit energy loss, by taking the high-voltage capacitor bypass resistance and the capacitor of the passive snubber circuit into account, we establish the relationship between the rising time and the shutdown time. Since the switch is not ideal, we propose a new method to test the shutdown time by the low voltage, the high voltage and the peak current. Experimental results show that adjustment of the current rising time can precisely control the value of the clamp voltage. When the rising time is fixed, the shutdown time is unchanged. The error for shutdown time deduced from the energy consumption is less than 6%. The new controlling method on current shutdown proposed in this paper can be used in the cooperative work of borehole and ground transmitting system.

  18. Bipolar square-wave current source for transient electromagnetic systems based on constant shutdown time.

    PubMed

    Wang, Shilong; Yin, Changchun; Lin, Jun; Yang, Yu; Hu, Xueyan

    2016-03-01

    Cooperative work of multiple magnetic transmitting sources is a new trend in the development of transient electromagnetic system. The key is the bipolar current waves shutdown, concurrently in the inductive load. In the past, it was difficult to use the constant clamping voltage technique to realize the synchronized shutdown of currents with different peak values. Based on clamping voltage technique, we introduce a new controlling method with constant shutdown time. We use the rising time to control shutdown time and use low voltage power source to control peak current. From the viewpoint of the circuit energy loss, by taking the high-voltage capacitor bypass resistance and the capacitor of the passive snubber circuit into account, we establish the relationship between the rising time and the shutdown time. Since the switch is not ideal, we propose a new method to test the shutdown time by the low voltage, the high voltage and the peak current. Experimental results show that adjustment of the current rising time can precisely control the value of the clamp voltage. When the rising time is fixed, the shutdown time is unchanged. The error for shutdown time deduced from the energy consumption is less than 6%. The new controlling method on current shutdown proposed in this paper can be used in the cooperative work of borehole and ground transmitting system.

  19. Dark Current Reduction of IR Detectors

    DTIC Science & Technology

    2017-10-19

    demonstrating a novel dark current reduction approach for dense infrared detector arrays. This technique is based on the diffusion control junction (DCJ...fabricate and test detector arrays with and without DCJs on the same wafer and demonstrate the effectiveness of the DCJ approach in reducing dark current...subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE

  20. Error field optimization in DIII-D using extremum seeking control

    DOE PAGES

    Lanctot, M. J.; Olofsson, K. E. J.; Capella, M.; ...

    2016-06-03

    A closed-loop error field control algorithm is implemented in the Plasma Control System of the DIII-D tokamak and used to identify optimal control currents during a single plasma discharge. The algorithm, based on established extremum seeking control theory, exploits the link in tokamaks between maximizing the toroidal angular momentum and minimizing deleterious non-axisymmetric magnetic fields. Slowly-rotating n = 1 fields (the dither), generated by external coils, are used to perturb the angular momentum, monitored in real-time using a charge-exchange spectroscopy diagnostic. Simple signal processing of the rotation measurements extracts information about the rotation gradient with respect to the control coilmore » currents. This information is used to converge the control coil currents to a point that maximizes the toroidal angular momentum. The technique is well-suited for multi-coil, multi-harmonic error field optimizations in disruption sensitive devices as it does not require triggering locked tearing modes or plasma current disruptions. Control simulations highlight the importance of the initial search direction on the rate of the convergence, and identify future algorithm upgrades that may allow more rapid convergence that projects to convergence times in ITER on the order of tens of seconds.« less

  1. Design optimization of high frequency transformer with controlled leakage inductance for current fed dual active bridge converter

    NASA Astrophysics Data System (ADS)

    Jung, Tae-Uk; Kim, Myung-Hwan; Yoo, Jin-Hyung

    2018-05-01

    Current fed dual active bridge converters for photovoltaic generation may typically require a given leakage or extra inductance in order to provide proper control of the currents. Therefore, the many researches have been focused on the leakage inductance control of high frequency transformer to integrate an extra inductor. In this paper, an asymmetric winding arrangement to get the controlled leakage inductance for the high frequency transformer is proposed to improve the efficiency of the current fed dual active bridge converter. In order to accurate analysis, a coupled electromagnetic analysis model of transformer connected with high frequency switching circuit is used. A design optimization procedure for high efficiency is also presented using design analysis model, and it is verified by the experimental result.

  2. Plasma source for spacecraft potential control

    NASA Technical Reports Server (NTRS)

    Olsen, R. C.

    1983-01-01

    A stable electrical ground which enables the particle spectrometers to measure the low energy particle populations was investigated and the current required to neutralize the spacecraft was measured. In addition, the plasma source for potential control (PSPO C) prevents high charging events which could affect the spacecraft electrical integrity. The plasma source must be able to emit a plasma current large enough to balance the sum of all other currents to the spacecraft. In ion thrusters, hollow cathodes provide several amperes of electron current to the discharge chamber. The PSPO C is capable of balancing the net negative currents found in eclipse charging events producing 10 to 100 microamps of electron current. The largest current required is the ion current necessary to balance the total photoelectric current.

  3. Particle-in-cell simulations of electron beam control using an inductive current divider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swanekamp, S. B.; Angus, J. R.; Cooperstein, G.

    2015-11-15

    Kinetic, time-dependent, electromagnetic, particle-in-cell simulations of the inductive current divider are presented. The inductive current divider is a passive method for controlling the trajectory of an intense, hollow electron beam using a vacuum structure that inductively splits the beam's return current. The current divider concept was proposed and studied theoretically in a previous publication [Swanekamp et al., Phys. Plasmas 22, 023107 (2015)]. A central post carries a portion of the return current (I{sub 1}), while the outer conductor carries the remainder (I{sub 2}) with the injected beam current given by I{sub b} = I{sub 1} + I{sub 2}. The simulations are in agreement withmore » the theory which predicts that the total force on the beam trajectory is proportional to (I{sub 2}−I{sub 1}) and the force on the beam envelope is proportional to I{sub b}. Independent control over both the current density and the beam angle at the target is possible by choosing the appropriate current-divider geometry. The root-mean-square (RMS) beam emittance (ε{sub RMS}) varies as the beam propagates through the current divider to the target. For applications where control of the beam trajectory is desired and the current density at the target is similar to the current density at the entrance foil, there is a modest 20% increase in ε{sub RMS} at the target. For other applications where the beam is pinched to a current density ∼5 times larger at the target, ε{sub RMS} is 2–3 times larger at the target.« less

  4. Harmonic Composition of the Currents of Power Windings in 500 KV Thyristor Controlled Shunt Reactor with Split Valveside Windings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matinyan, A. M., E-mail: al-drm@mail.ru; Peshkov, M. V.; Karpov, V. N.

    2016-09-15

    The design and current spectrum of a thyristor valve controlled shunt reactor (TCSR) with split valveside windings are described. The dependence of the amplitudes of higher-order harmonics of the power winding current on the TCSR operating regime are presented for this TCSR design.

  5. 37 CFR 1.419 - Display of currently valid control number under the Paperwork Reduction Act.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Display of currently valid... UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE GENERAL RULES OF PRACTICE IN PATENT CASES International Processing Provisions General Information § 1.419 Display of currently valid control...

  6. Effects of transcutaneous electrical nerve stimulation (TENS) and interferential currents (IFC) in patients with nonspecific chronic low back pain: randomized clinical trial.

    PubMed

    Facci, Ligia Maria; Nowotny, Jean Paulus; Tormem, Fabio; Trevisani, Virgínia Fernandes Moça

    2011-01-01

    Transcutaneous electrical nerve stimulation (TENS) and interferential current are the most used electrotherapy methods, although there is little scientific evidence to support their use. The aim of this study was to compare the effects of TENS and interferential current among patients with nonspecific chronic low back pain. Single-blind randomized controlled trial in the Department of Physiotherapy, Centro Universitário de Maringá. One hundred and fifty patients were randomly divided into three groups: TENS (group 1), interferential current (group 2) and controls (group 3). The patients designated for electrotherapy received ten 30-minute sessions, while the control group remained untreated. All patients and controls were evaluated before and after treatment using a visual analog scale and the McGill Pain and Roland Morris questionnaires, and regarding their use of additional medications. There was a mean reduction on the visual analog scale of 39.18 mm with TENS, 44.86 mm with interferential current and 8.53 mm among the controls. In the Roland Morris questionnaire, group 1 had a mean reduction of 6.59; group 2, 7.20; and group 3, 0.70 points. In group 1, 84% of the patients stopped using medications after the treatment; in group 2, 75%; and in group 3, 34%. There was no statistically significant difference between the TENS and interferential current groups (P > 0.05); a difference was only found between these groups and the controls (P < 0.0001). There was no difference between TENS and interferential current for chronic low back pain treatment. NCT01017913.

  7. German EstSmoke: estimating adult smoking-related costs and consequences of smoking cessation for Germany.

    PubMed

    Sonntag, Diana; Gilbody, Simon; Winkler, Volker; Ali, Shehzad

    2018-01-01

    We compared predicted life-time health-care costs for current, never and ex-smokers in Germany under the current set of tobacco control polices. We compared these economic consequences of the current situation with an alternative in which Germany were to implement more comprehensive tobacco control policies consistent with the World Health Organization (WHO) Framework Convention for Tobacco Control (FCTC) guidelines. German EstSmoke, an adapted version of the UK EstSmoke simulation model, applies the Markov modelling approach. Transition probabilities for (re-)currence of smoking-related diseases were calculated from large German disease-specific registries and the German Health Update (GEDA 2010). Estimations of both health-care costs and effect sizes of smoking cessation policies were taken from recent German studies and discounted at 3.5%/year. Germany. German population of prevalent current, never and ex-smokers in 2009. Life-time cost and outcomes in current, never and ex-smokers. If tobacco control policies are not strengthened, the German smoking population will incur €41.56 billion life-time excess costs compared with never smokers. Implementing tobacco control policies consistent with WHO FCTC guidelines would reduce the difference of life-time costs between current smokers and ex-smokers by at least €1.7 billion. Modelling suggests that the life-time healthcare costs of people in Germany who smoke are substantially greater than those of people who have never smoked. However, more comprehensive tobacco control policies could reduce health-care expenditures for current smokers by at least 4%. © 2017 Society for the Study of Addiction.

  8. Two Ca current components of the receptor current in the electroreceptors of the marine catfish Plotosus.

    PubMed

    Sugawara, Y

    1989-02-01

    In the isolated sensory epithelium of the Plotosus electroreceptor, the receptor current has been dissected into inward Ca current, ICa, and superimposed outward transient of Ca-gated K current, IK(Ca). In control saline (170 mM/liter Na), with IK(Ca) abolished by K blockers, ICa declined in two successive exponential phases with voltage-dependent time constants. Double-pulse experiments revealed that the test ICa was partially depressed by prepulses, maximally near voltage levels for the control ICa maximum, which suggests current-dependent inactivation. In low Na saline (80 mM/liter), ICa declined in a single phase with time constants similar to those of the slower phase in control saline. The test ICa was then unaffected by prepulses. The implied presence of two Ca current components, the fast and slow ICa's, were further examined. In control saline, the PSP externally recorded from the afferent nerve showed a fast peak and a slow tonic phase. The double-pulse experiments revealed that IK(Ca) and the peak PSP were similarly depressed, i.e., secondarily to inactivation of the peak current. The steady inward current, however, was unaffected by prolonged prepulses that were stepped to 0 mV, the in situ DC level. Therefore, the fast ICa seems to initiate IK(Ca) and phasic release of transmitter, which serves for phasic receptor responses. The slow ICa may provide persistent active current, which has been shown to maintain tonic receptor operation.

  9. Development of Electronic Load Controllers for Free-Piston Stirling Convertors Aided by Stirling Simulation Model

    NASA Technical Reports Server (NTRS)

    Regan, Timothy F.

    2004-01-01

    The free-piston Stirling convertor end-to-end modeling effort at the NASA Glenn Research Center has produced a software-based test bed in which free-piston Stirling convertors can be simulated and evaluated. The simulation model includes all the components of the convertor: the Stirling cycle engine, heat source, linear alternator, controller, and load. So far, it has been used in evaluating the performance of electronic controller designs. Three different controller design concepts were simulated using the model: 1) Controllers with parasitic direct current loading. 2) Controllers with parasitic alternating current loading. 3) Controllers that maintain a reference current. The free-piston Stirling convertor is an electromechanical device that operates at resonance. It is the function of the electronic load controller to ensure that the electrical load seen by the machine is always great enough to keep the amplitude of the piston and alternator oscillation at the rated value. This is done by regulating the load on the output bus. The controller monitors the instantaneous voltage, regulating it by switching loads called parasitic loads onto the bus whenever the bus voltage is too high and removing them whenever the voltage is too low. In the first type of controller, the monitor-ing and switching are done on the direct-current (dc) bus. In the second type, the alternating current bus is used. The model allows designers to test a controller concept before investing time in hardware. The simulation code used to develop the model also offers detailed models of digital and analog electronic components so that the resulting designs are realistic enough to translate directly into hardware circuits.

  10. 40 CFR 430.112 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... effluent reduction attainable by the application of the best practicable control technology currently... reduction attainable by the application of the best practicable control technology currently available (BPT...

  11. 40 CFR 420.42 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... best practicable control technology currently available. (a) Electric arc furnace steelmaking—semi-wet... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR...

  12. 40 CFR 445.11 - Effluent limitations attainable by the application of the best practicable control technology...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... application of the best practicable control technology currently available (BPT). 445.11 Section 445.11... attainable by the application of the best practicable control technology currently available (BPT). Except as... the following effluent limitations which represent the application of BPT: Effluent Limitations...

  13. 40 CFR 440.72 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable by the application of the best practicable control technology currently available (BPT...

  14. 40 CFR 440.12 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable after application of the best practicable control technology currently available (BPT...

  15. 40 CFR 440.22 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in... application of the best practicable control technology currently available (BPT). The concentration of...

  16. 40 CFR 440.62 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable by the application of the best practicable control technology currently available (BPT...

  17. 40 CFR 440.62 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in... attainable by the application of the best practicable control technology currently available (BPT): (a) The...

  18. 40 CFR 440.72 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in... attainable by the application of the best practicable control technology currently available (BPT): (a) The...

  19. 40 CFR 440.12 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable after application of the best practicable control technology currently available (BPT...

  20. 40 CFR 440.42 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable after application of the best practicable control technology currently available (BPT...

  1. 40 CFR 440.22 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... attainable by the application of the best practicable control technology currently available (BPT). The...

  2. 40 CFR 440.72 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable by the application of the best practicable control technology currently available (BPT...

  3. 40 CFR 440.42 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable after application of the best practicable control technology currently available (BPT...

  4. 40 CFR 440.22 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in... application of the best practicable control technology currently available (BPT). The concentration of...

  5. 40 CFR 440.62 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in... attainable by the application of the best practicable control technology currently available (BPT): (a) The...

  6. 40 CFR 440.42 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in... attainable after application of the best practicable control technology currently available (BPT): (a) The...

  7. 40 CFR 440.62 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable by the application of the best practicable control technology currently available (BPT...

  8. 40 CFR 440.12 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable after application of the best practicable control technology currently available (BPT...

  9. 40 CFR 440.22 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... attainable by the application of the best practicable control technology currently available (BPT). The...

  10. 40 CFR 440.72 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in... attainable by the application of the best practicable control technology currently available (BPT): (a) The...

  11. 40 CFR 440.72 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable by the application of the best practicable control technology currently available (BPT...

  12. 40 CFR 440.42 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable after application of the best practicable control technology currently available (BPT...

  13. 40 CFR 440.62 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... reduction attainable by the application of the best practicable control technology currently available (BPT...

  14. 40 CFR 440.12 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in... attainable after application of the best practicable control technology currently available (BPT): (a) The...

  15. 40 CFR 440.22 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... attainable by the application of the best practicable control technology currently available (BPT). Except as... attainable by the application of the best practicable control technology currently available (BPT). The...

  16. 77 FR 34004 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-08

    ... displays a currently valid OMB control number and the agency informs potential persons who are to respond... information unless it displays a currently valid OMB control number. Rural Housing Service Title: 7 CFR 1944-I, ``Self-Help Technical Assistance Grants''. OMB Control Number: 0575-0043. Summary of Collection: This...

  17. Internet and Information Control: The Case of China.

    ERIC Educational Resources Information Center

    Xiaoming, Hao; Zhang, Kewen; Yu, Huang

    1996-01-01

    Examines the potential impact of computer-mediated communication (CMC) on government controls of information in China. Examines the current development of CMC in China; challenges posed by new media technologies to government information control; and the current policy of the Chinese government towards on-line communication and its implications.…

  18. Alternating-Current Motor Drive for Electric Vehicles

    NASA Technical Reports Server (NTRS)

    Krauthamer, S.; Rippel, W. E.

    1982-01-01

    New electric drive controls speed of a polyphase as motor by varying frequency of inverter output. Closed-loop current-sensing circuit automatically adjusts frequency of voltage-controlled oscillator that controls inverter frequency, to limit starting and accelerating surges. Efficient inverter and ac motor would give electric vehicles extra miles per battery charge.

  19. 78 FR 17181 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ... currently valid OMB control number and the agency informs potential persons who are to respond to the... unless it displays a currently valid OMB control number. Animal and Plant Health Inspection Service Title: Federal Plant Pest, Noxious Weed, and Garbage Regulations. OMB Control Number: 0579-0054. Summary of...

  20. 40 CFR 420.42 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... best practicable control technology currently available. (a) Electric arc furnace steelmaking—semi-wet... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR...

  1. 40 CFR 420.42 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... best practicable control technology currently available. (a) Electric arc furnace steelmaking—semi-wet... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR...

  2. 40 CFR 420.42 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... best practicable control technology currently available. (a) Electric arc furnace steelmaking—semi-wet... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR...

  3. 40 CFR 430.112 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... effluent reduction attainable by the application of the best practicable control technology currently... reduction attainable by the application of the best practicable control technology currently available (BPT...

  4. 40 CFR 420.42 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... best practicable control technology currently available. (a) Electric arc furnace steelmaking—semi-wet... degree of effluent reduction attainable by the application of the best practicable control technology... application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR...

  5. Functional abdominal pain in childhood and long-term vulnerability to anxiety disorders.

    PubMed

    Shelby, Grace D; Shirkey, Kezia C; Sherman, Amanda L; Beck, Joy E; Haman, Kirsten; Shears, Angela R; Horst, Sara N; Smith, Craig A; Garber, Judy; Walker, Lynn S

    2013-09-01

    Cross-sectional studies link functional abdominal pain (FAP) to anxiety and depression in childhood, but no prospective study has evaluated psychiatric status in adulthood or its relation to pain persistence. Pediatric patients with FAP (n = 332) and control subjects (n = 147) were tracked prospectively and evaluated for psychiatric disorders and functional gastrointestinal disorders (FGIDs) at follow-up in adolescence and young adulthood (mean age = 20.01 years). Participants were classified according to presence (FGID-POS) or absence (FGID-NEG) of FGIDs at follow-up. Lifetime and current risk of anxiety disorders was higher in FAP than controls (lifetime: 51% vs 20%; current: 30% vs 12%). Controlling for gender and age, the odds ratio was 4.9 (confidence interval = 2.83-7.43) for lifetime anxiety disorder and 3.57 (confidence interval = 2.00-6.36) for current anxiety disorder at follow-up for FAP versus controls. Lifetime risk of depressive disorder was significantly higher in FAP versus controls (40% vs. 16%); current risk did not differ. In most cases, initial onset of anxiety disorders was before pediatric FAP evaluation; onset of depressive disorders was subsequent to FAP evaluation. Within the FAP group, risk of current anxiety disorders at follow-up was significantly higher for FGID-POS versus FGID-NEG (40% vs 24%), and both were higher than controls (12%); current depressive disorders did not differ across FGID-POS, FGID-NEG, and controls. Patients with FAP carry long-term vulnerability to anxiety that begins in childhood and persists into late adolescence and early adulthood, even if abdominal pain resolves.

  6. StimDuino: an Arduino-based electrophysiological stimulus isolator.

    PubMed

    Sheinin, Anton; Lavi, Ayal; Michaelevski, Izhak

    2015-03-30

    Electrical stimulus isolator is a widely used device in electrophysiology. The timing of the stimulus application is usually automated and controlled by the external device or acquisition software; however, the intensity of the stimulus is adjusted manually. Inaccuracy, lack of reproducibility and no automation of the experimental protocol are disadvantages of the manual adjustment. To overcome these shortcomings, we developed StimDuino, an inexpensive Arduino-controlled stimulus isolator allowing highly accurate, reproducible automated setting of the stimulation current. The intensity of the stimulation current delivered by StimDuino is controlled by Arduino, an open-source microcontroller development platform. The automatic stimulation patterns are software-controlled and the parameters are set from Matlab-coded simple, intuitive and user-friendly graphical user interface. The software also allows remote control of the device over the network. Electrical current measurements showed that StimDuino produces the requested current output with high accuracy. In both hippocampal slice and in vivo recordings, the fEPSP measurements obtained with StimDuino and the commercial stimulus isolators showed high correlation. Commercial stimulus isolators are manually managed, while StimDuino generates automatic stimulation patterns with increasing current intensity. The pattern is utilized for the input-output relationship analysis, necessary for assessment of excitability. In contrast to StimuDuino, not all commercial devices are capable for remote control of the parameters and stimulation process. StimDuino-generated automation of the input-output relationship assessment eliminates need for the current intensity manually adjusting, improves stimulation reproducibility, accuracy and allows on-site and remote control of the stimulation parameters. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Fast chirality reversal of the magnetic vortex by electric current

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, W. L., E-mail: wlimnd@gmail.com; Liu, R. H.; Urazhdin, S., E-mail: sergei.urazhdin@emory.edu

    2014-12-01

    The possibility of high-density information encoding in magnetic materials by topologically stable inhomogeneous magnetization configurations such as domain walls, skyrmions, and vortices has motivated intense research into mechanisms enabling their control and detection. While the uniform magnetization states can be efficiently controlled by electric current using magnetic multilayer structures, this approach has proven much more difficult to implement for inhomogeneous states. Here, we report direct observation of fast reversal of magnetic vortex by electric current in a simple planar structure based on a bilayer of spin Hall material Pt with a single microscopic ferromagnetic disk contacted by asymmetric electrodes. Themore » reversal is enabled by a combination of the chiral Oersted field and spin current generated by the nonuniform current distribution in Pt. Our results provide a route for the efficient control of inhomogeneous magnetization configurations by electric current.« less

  8. Resting state synchrony in long-term abstinent alcoholics: Effects of a current major depressive disorder diagnosis.

    PubMed

    Fein, George; Camchong, Jazmin; Cardenas, Valerie A; Stenger, Andy

    2017-03-01

    Alcoholism is characterized by a lack of control over an impulsive and compulsive drive toward excessive alcohol consumption despite significant negative consequences; our previous work demonstrated that successful abstinence is characterized by decreased resting-state synchrony (RSS) as measured with functional magnetic resonance imaging (fMRI), within appetitive drive networks and increased RSS in emotion regulation and inhibitory executive control networks. Our hypothesis is that LTAA (Long-Term Abstinent Alcoholics) with a current major depressive disorder (MDD) drank primarily to deal with the negative affect associated with their MDD and not because of a heightened externalizing diathesis (including heightened appetitive drive), and consequently, in achieving and maintaining abstinence, such individuals would not exhibit the RSS adaptations characteristic of pure alcoholics. We studied 69 NSAC (Non Substance Abusing Controls) and 40 LTAA (8 with current MDD, 32 without a current MDD) using resting-state fMRI and seed based connectivity analyses. In the inhibitory executive control network (nucleus accumbens vs. left dorsolateral prefrontal cortex), LTAA with a current MDD showed increased synchrony compared to NSAC. In the emotion regulation executive control network (subgenual anterior cingulate cortex vs. right dorsolateral prefrontal cortex), LTAA with current MDD did not show increased RSS. In the appetitive drive networks (nucleus accumbens vs, aspects of the caudate nucleus and thalamus), LTAA with a current MDD did not show a reduction of RSS compared to NSAC, but LTAA without a current MDD did. These results suggest different pathways to their alcohol dependence in LTAA with vs. without a current MDD, and different patterns of brain activity in long-term abstinence, suggesting different treatment needs. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Resting state synchrony in long-term abstinent alcoholics: Effects of a current major depressive disorder diagnosis

    PubMed Central

    Fein, George; Camchong, Jazmin; Cardenas, Valerie A.; Stenger, Andy

    2017-01-01

    Alcoholism is characterized by a lack of control over an impulsive and compulsive drive toward excessive alcohol consumption despite significant negative consequences; our previous work demonstrated that successful abstinence is characterized by decreased resting-state synchrony (RSS) as measured with functional magnetic resonance imaging (fMRI), within appetitive drive networks and increased RSS in emotion regulation and inhibitory executive control networks. Our hypothesis is that LTAA (Long-Term Abstinent Alcoholics) with a current major depressive disorder (MDD) drank primarily to deal with the negative affect associated with their MDD and not because of a heightened externalizing diathesis (including heightened appetitive drive), and consequently, in achieving and maintaining abstinence, such individuals would not exhibit the RSS adaptations characteristic of pure alcoholics. We studied 69 NSAC (Non Substance Abusing Controls) and 40 LTAA (8 with current MDD, 32 without a current MDD) using resting-state fMRI and seed based connectivity analyses. In the inhibitory executive control network (nucleus accumbens vs. left dorsolateral prefrontal cortex), LTAA with a current MDD showed increased synchrony compared to NSAC. In the emotion regulation executive control network (subgenual anterior cingulate cortex vs. right dorsolateral prefrontal cortex), LTAA with current MDD did not show increased RSS. In the appetitive drive networks (nucleus accumbens vs, aspects of the caudate nucleus and thalamus), LTAA with a current MDD did not show a reduction of RSS compared to NSAC, but LTAA without a current MDD did. These results suggest different pathways to their alcohol dependence in LTAA with vs. without a current MDD, and different patterns of brain activity in long-term abstinence, suggesting different treatment needs. PMID:28262184

  10. Design and application of electromechanical actuators for deep space missions

    NASA Technical Reports Server (NTRS)

    Haskew, Tim A.; Wander, John

    1993-01-01

    The annual report Design and Application of Electromechanical Actuators for Deep Space Missions is presented. The reporting period is 16 Aug. 1992 to 15 Aug. 1993. However, the primary focus will be work performed since submission of our semi-annual progress report in Feb. 1993. Substantial progress was made. We currently feel confident in providing guidelines for motor and control strategy selection in electromechanical actuators to be used in thrust vector control (TVC) applications. A small portion was presented in the semi-annual report. At this point, we have implemented highly detailed simulations of various motor/drive systems. The primary motor candidates were the brushless dc machine, permanent magnet synchronous machine, and the induction machine. The primary control implementations were pulse width modulation and hysteresis current control. Each of the two control strategies were applied to each of the three motor choices. With either pulse width modulation or hysteresis current control, the induction machine was always vector controlled. A standard test position command sequence for system performance evaluation is defined. Currently, we are gathering all of the necessary data for formal presentation of the results. Briefly stated for TVC application, we feel that the brushless dc machine operating under PWM current control is the best option. Substantial details on the topic, with supporting simulation results, will be provided later, in the form of a technical paper prepared for submission and also in the next progress report with more detail than allowed for paper publication.

  11. Modeling of the control of the driven current profile in ICRF MCCD on EAST plasma

    NASA Astrophysics Data System (ADS)

    Yin, L.; Yang, C.; Gong, X. Y.; Lu, X. Q.; Cao, J. J.; Wu, Z. Y.; Chen, Y.; Du, D.

    2018-05-01

    Control of the current profile is a crucial issue for improved confinement and the inhibition of instability in advanced tokamak operation. Using typical discharge data for the Experimental Advanced Superconducting Tokamak, numerical simulations of driven-current profile control in mode conversion current drive (MCCD) in the ion cyclotron range of frequencies were performed employing a full-wave method and Ehst-Karney efficiency formula. Results indicate that the driven current profile in MCCD can be effectively modified by shifting the mode conversion layer. The peak of the driven current can be located at an aimed position in the normalized minor radius range (-0.60 ≤r/a≤0) by changing the radiofrequency and the minority-ion concentration. The efficiency of the off-axis MCCD can reach 233 kA/MW through optimization, and the mode converted ion cyclotron wave plays an important role in such scenarios. The effects of electron temperature and plasma density on the driven current profile are also investigated.

  12. Bus current analysis of high power cryocooler's controller

    NASA Astrophysics Data System (ADS)

    Jin, Zhanlei; Sun, Qiyang; Dai, Liqun; Dong, Jie

    2016-03-01

    Current analysis was an important research content for reducing power of cryocooler's controller. Simulation was done among load current, H bridge current and power current refer to 42V bus power voltage. Then relationship among IL1, IC1, ρ and IM1 was established. Simulation results indicate that IL1-max, IL1-ave, IL1-rms, IC1-min and IC1-ave were linearly increasing to ρ and IM1, especially IL1-rms ≈ 0.612ρ IM1-max . IC1-rms increase firstly then decrease with the increasing of ρ. IC1-rms reaches maximum when ρ=0.8, then ICL-rms =(12.32/RM1 + 0.98) exp -((ρ-0.78)/0.57)2. The results were useful for miniaturizing cryocooler's controller.

  13. Indirect current control with separate IZ drop compensation for voltage source converters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanetkar, V.R.; Dawande, M.S.; Dubey, G.K.

    1995-12-31

    Indirect Current Control (ICC) of boost type Voltage Source Converters (VSCs) using separate compensation of line IZ voltage drop is presented. A separate bi-directional VSC is used to produce the compensation voltage. This simplifies the ICC regulator scheme as the power flow is controlled through single modulation index. Experimental verification is provided for bi-directional control of the power flow.

  14. Electrically controlled optical latch and switch requires less current

    NASA Technical Reports Server (NTRS)

    Pieczonka, W. A.; Roy, M. M.; Yeh, T. H.

    1966-01-01

    Electrically controlled optical latch consists of a sensitive phototransistor and a solid-state light source. This design requires less current to activate an optically activated switch than in prior art.

  15. Bending strain engineering in quantum spin hall system for controlling spin currents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Bing; Jin, Kyung-Hwan; Cui, Bin

    Quantum spin Hall system can exhibit exotic spin transport phenomena, mediated by its topological edge states. The concept of bending strain engineering to tune the spin transport properties of a quantum spin Hall system is demonstrated. Here, we show that bending strain can be used to control the spin orientation of counter-propagating edge states of a quantum spin system to generate a non-zero spin current. This physics mechanism can be applied to effectively tune the spin current and pure spin current decoupled from charge current in a quantum spin Hall system by control of its bending curvature. Moreover, the curvedmore » quantum spin Hall system can be achieved by the concept of topological nanomechanical architecture in a controllable way, as demonstrated by the material example of Bi/Cl/Si(111) nanofilm. This concept of bending strain engineering of spins via topological nanomechanical architecture affords a promising route towards the realization of topological nano-mechanospintronics.« less

  16. Bending strain engineering in quantum spin hall system for controlling spin currents

    DOE PAGES

    Huang, Bing; Jin, Kyung-Hwan; Cui, Bin; ...

    2017-06-16

    Quantum spin Hall system can exhibit exotic spin transport phenomena, mediated by its topological edge states. The concept of bending strain engineering to tune the spin transport properties of a quantum spin Hall system is demonstrated. Here, we show that bending strain can be used to control the spin orientation of counter-propagating edge states of a quantum spin system to generate a non-zero spin current. This physics mechanism can be applied to effectively tune the spin current and pure spin current decoupled from charge current in a quantum spin Hall system by control of its bending curvature. Moreover, the curvedmore » quantum spin Hall system can be achieved by the concept of topological nanomechanical architecture in a controllable way, as demonstrated by the material example of Bi/Cl/Si(111) nanofilm. This concept of bending strain engineering of spins via topological nanomechanical architecture affords a promising route towards the realization of topological nano-mechanospintronics.« less

  17. Modeling the Association between Lifecourse Socioeconomic Disadvantage and Systemic Inflammation in Healthy Adults: The Role of Self-Control

    PubMed Central

    Hostinar, Camelia E.; Ross, Kharah M.; Chen, Edith; Miller, Gregory E.

    2015-01-01

    Objective We sought to identify pathways connecting lifecourse socioeconomic status (SES) with chronic, low-grade inflammation, focusing on the explanatory roles of self-control, abdominal adiposity, and health practices. Methods Participants were 360 adults aged 15 - 55 who were free of chronic medical conditions. They were roughly equally divided between low and high current SES, with each group further divided between low and high early-life SES. Structural Equation Modeling (SEM) was used to identify direct and indirect pathways linking early-life and current SES with low-grade, chronic inflammation in adulthood, as manifest by serum interleukin-6 and C-reactive protein. Low SES was hypothesized to relate to inflammation by reducing self-control, which in turn was hypothesized to facilitate lifestyle factors that potentiate inflammation (smoking, alcohol use, sedentary behavior, and weight gain). Results Analyses revealed that self-control was pivotal in linking both early-life and current SES to inflammation. Low early-life SES was related to a harsher family climate, and in turn lower adult self-control, over and above the effects of current SES. Controlling for early-life SES, low current SES was associated with perceived stress, and in turn diminished self-control. Results showed that lower self-control primarily operated through higher abdominal adiposity to associate with greater inflammation. Conclusions The findings suggest a mechanistic scenario wherein low SES in early-life or adulthood depletes self-control and in turn fosters adiposity and inflammation. These pathways should be studied longitudinally to elucidate and potentially ameliorate socioeconomic disparities in health. PMID:25110854

  18. The Galileo scan platform pointing control system - A modern control theoretic viewpoint

    NASA Technical Reports Server (NTRS)

    Sevaston, G. E.; Macala, G. A.; Man, G. K.

    1985-01-01

    The current Galileo scan platform pointing control system (SPPCS) is described, and ways in which modern control concepts could serve to enhance it are considered. Of particular interest are: the multi-variable design model and overall control system architecture, command input filtering, feedback compensator and command input design, stability robustness constraint for both continuous time control systems and for sampled data control systems, and digital implementation of the control system. The proposed approach leads to the design of a system that is similar to current Galileo SPPCS configuration, but promises to be more systematic.

  19. Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Current and advanced act control system definition study

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The Current and Advanced Technology ACT control system definition tasks of the Integrated Application of Active Controls (IAAC) Technology project within the Energy Efficient Transport Program are summarized. The systems mechanize six active control functions: (1) pitch augmented stability; (2) angle of attack limiting; (3) lateral/directional augmented stability; (4) gust load alleviation; (5) maneuver load control; and (6) flutter mode control. The redundant digital control systems meet all function requirements with required reliability and declining weight and cost as advanced technology is introduced.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Jinyuan

    A digitization scheme of sub-microampere current using a commercial comparator with adjustable hysteresis and FPGA-based Wave Union TDC has been tested. The comparator plus a few passive components forms a current controlled oscillator and the input current is sent into the hysteresis control pin. The input current is converted into the transition times of the oscillations, which are digitized with a Wave Union TDC in FPGA and the variation of the transition times reflects the variation of the input current. Preliminary tests show that input charges < 25 fC can be measured at > 50 M samples/s without a preamplifier.

  1. Power Maximization Control of Variable Speed Wind Generation System Using Permanent Magnet Synchronous Generator

    NASA Astrophysics Data System (ADS)

    Morimoto, Shigeo; Nakamura, Tomohiko; Takeda, Yoji

    This paper proposes the sensorless output power maximization control of the wind generation system. A permanent magnet synchronous generator (PMSG) is used as a variable speed generator in the proposed system. The generator torque is suitably controlled according to the generator speed and thus the power from a wind turbine settles down on the maximum power point by the proposed MPPT control method, where the information of wind velocity is not required. Moreover, the maximum available generated power is obtained by the optimum current vector control. The current vector of PMSG is optimally controlled according to the generator speed and the required torque in order to minimize the losses of PMSG considering the voltage and current constraints. The proposed wind power generation system can be achieved without mechanical sensors such as a wind velocity detector and a position sensor. Several experimental results show the effectiveness of the proposed control method.

  2. Scrape-off-layer characterization and current-control of kink modes in HBT-EP

    NASA Astrophysics Data System (ADS)

    Brooks, John; Stewart, Ian; Levesque, Jeffrey; Mauel, Mike; Navratil, Gerald

    2017-10-01

    Scrape-off layer (SOL) currents and their paths through tokamaks are not well understood, but their control may prove crucial to the success of ITER and future fusion energy devices. We extend Columbia University's High Beta Tokamak-Extended Pulse (HBT-EP) experiment and active GPU feedback system to study the SOL and control MHD kink instabilities by actively controlling these currents. First, the radial plasma profiles and the edge structure of kink instabilities are measured with two triple probes. Second, we use active feedback control of a radially adjustable biased electrode to change the rotation and magnitude of slowly growing kink instabilities. By changing the phase between the probe's voltage and the edge instability with active feedback, we study its ability to influence and control plasma MHD structures. This work is in preparation for a planned 2018 multi-electrode SOL control upgrade. Supported by U.S. DOE Grant DE-FG02-86ER53222.

  3. 40 CFR 434.82 - Effluent limitations attainable by the application of the best practicable control technology...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... application of the best practicable control technology currently available (BPT). 434.82 Section 434.82... practicable control technology currently available (BPT). Except as provided in 40 CFR 125.30 through 125.32, the following effluent limitations apply to mine drainage from applicable areas of western coal mining...

  4. 40 CFR 434.82 - Effluent limitations attainable by the application of the best practicable control technology...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... application of the best practicable control technology currently available (BPT). 434.82 Section 434.82... control technology currently available (BPT). Except as provided in 40 CFR 125.30 through 125.32, the following effluent limitations apply to mine drainage from applicable areas of western coal mining...

  5. 40 CFR 434.82 - Effluent limitations attainable by the application of the best practicable control technology...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... application of the best practicable control technology currently available (BPT). 434.82 Section 434.82... practicable control technology currently available (BPT). Except as provided in 40 CFR 125.30 through 125.32, the following effluent limitations apply to mine drainage from applicable areas of western coal mining...

  6. 40 CFR 434.82 - Effluent limitations attainable by the application of the best practicable control technology...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... application of the best practicable control technology currently available (BPT). 434.82 Section 434.82... practicable control technology currently available (BPT). Except as provided in 40 CFR 125.30 through 125.32, the following effluent limitations apply to mine drainage from applicable areas of western coal mining...

  7. 40 CFR 434.82 - Effluent limitations attainable by the application of the best practicable control technology...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... application of the best practicable control technology currently available (BPT). 434.82 Section 434.82... control technology currently available (BPT). Except as provided in 40 CFR 125.30 through 125.32, the following effluent limitations apply to mine drainage from applicable areas of western coal mining...

  8. Trade Electricity. Motors & Controls--Level 3. Standardized Curriculum.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Office of Occupational and Career Education.

    This curriculum guide consists of seven modules on motors and controls, one of the three divisions of the standardized trade electricity curriculum in high schools in New York City. The seven modules cover the following subjects: energy conservation wiring, direct current (DC) motor repair and rewinding, DC motor controls, alternating current (AC)…

  9. Reexamination of color vision standards, part I : status of color use in ATC displays and demography of color-deficit controllers : final report.

    DOT National Transportation Integrated Search

    2006-02-01

    This report describes the status of color use in current air traffic control (ATC) displays. It represents the first step in our effort to reexamine the color vision standards for air traffic controllers. The current job-related color vision tests us...

  10. Differential Autonomic Nervous System Reactivity in Depression and Anxiety During Stress Depending on Type of Stressor.

    PubMed

    Hu, Mandy X; Lamers, Femke; de Geus, Eco J C; Penninx, Brenda W J H

    2016-06-01

    It remains unclear whether depressive and anxiety disorders are associated with hyporeactivity or hyperreactivity of the autonomic nervous system (ANS) and whether deviant reactivity occurs in all types of stressors. This study compared ANS reactivity in people with current or remitted depression/anxiety with reactivity in healthy controls during two stress conditions. From the Netherlands Study of Depression and Anxiety, data of 804 individuals with current depression/anxiety, 913 individuals with remitted depression/anxiety, and 466 healthy controls (mean age = 44.1 years; 66.4% female) were available. Two conditions were used to evoke stress: a) an n-back task, a cognitively challenging stressor, and 2) a psychiatric interview, evoking personal-emotional stress related to the occurrence of symptoms of depression/anxiety. Indicators of ANS activity were heart rate (HR), root mean square of differences between successive interbeat intervals (RMSSD), respiratory sinus arrhythmia (RSA), and preejection period. As compared with controls, participants with psychopathology had significant hyporeactivity of HR (controls = 4.1 ± 4.2 beats/min; remitted = 3.5 ± 3.5 beats/min; current psychopathology = 3.1 ± 3.4 beats/min), RMSSD (controls = -6.2 ± 14.5 milliseconds; remitted = -5.4 ± 17.8 milliseconds; current psychopathology = -3.5 ± 15.4 milliseconds), and RSA (controls = -9.3 ± 17.0 milliseconds; remitted = -7.4 ± 16.5 milliseconds; current psychopathology = -6.9 ± 15.0 milliseconds) during the n-back task. In contrast, during the psychiatric interview, they showed significant hyperreactivity of HR (controls = 2.7 ± 3.4 beats/min; remitted = 3.5 ± 3.4 beats/min; current psychopathology = 4.0 ± 3.3 beats/min), RMSSD (controls = -3.4 ± 12.2 milliseconds; remitted = -4.1 ± 12.1 milliseconds; current psychopathology = -5.6 ± 11.8 milliseconds), and RSA (controls = -3.8 ± 8.1 milliseconds; remitted = -4.3 ± 7.9 milliseconds; current psychopathology = -5.0 ± 7.9 milliseconds). The lack of group differences in preejection period reactivity suggests that the found effects were driven by altered cardiac vagal reactivity in depression/anxiety. The direction of altered ANS reactivity in depressed/anxious patients is dependent on the type of stressor, and only the more ecologically valid stressors may evoke hyperreactivity in these patients.

  11. Power Management Based Current Control Technique for Photovoltaic-Battery Assisted Wind-Hydro Hybrid System

    NASA Astrophysics Data System (ADS)

    Ram Prabhakar, J.; Ragavan, K.

    2013-07-01

    This article proposes new power management based current control strategy for integrated wind-solar-hydro system equipped with battery storage mechanism. In this control technique, an indirect estimation of load current is done, through energy balance model, DC-link voltage control and droop control. This system features simpler energy management strategy and necessitates few power electronic converters, thereby minimizing the cost of the system. The generation-demand (G-D) management diagram is formulated based on the stochastic weather conditions and demand, which would likely moderate the gap between both. The features of management strategy deploying energy balance model include (1) regulating DC-link voltage within specified tolerances, (2) isolated operation without relying on external electric power transmission network, (3) indirect current control of hydro turbine driven induction generator and (4) seamless transition between grid-connected and off-grid operation modes. Furthermore, structuring of the hybrid system with appropriate selection of control variables enables power sharing among each energy conversion systems and battery storage mechanism. By addressing these intricacies, it is viable to regulate the frequency and voltage of the remote network at load end. The performance of the proposed composite scheme is demonstrated through time-domain simulation in MATLAB/Simulink environment.

  12. Electrochemical biofilm control: a review.

    PubMed

    Sultana, Sujala T; Babauta, Jerome T; Beyenal, Haluk

    2015-01-01

    One of the methods of controlling biofilms that has widely been discussed in the literature is to apply a potential or electrical current to a metal surface on which the biofilm is growing. Although electrochemical biofilm control has been studied for decades, the literature is often conflicting, as is detailed in this review. The goals of this review are: (1) to present the current status of knowledge regarding electrochemical biofilm control; (2) to establish a basis for a fundamental definition of electrochemical biofilm control and requirements for studying it; (3) to discuss current proposed mechanisms; and (4) to introduce future directions in the field. It is expected that the review will provide researchers with guidelines on comparing datasets across the literature and generating comparable datasets. The authors believe that, with the correct design, electrochemical biofilm control has great potential for industrial use.

  13. Systems and methods for providing power to a load based upon a control strategy

    DOEpatents

    Perisic, Milun; Lawrence, Christopher P; Ransom, Ray M; Kajouke, Lateef A

    2014-11-04

    Systems and methods are provided for an electrical system. The electrical system, for example, includes a first load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage through the interface and to provide a voltage and current to the first load. The controller may be further configured to, receive information on a second load electrically connected to the voltage source, determine an amount of reactive current to return to the voltage source such that a current drawn by the electrical system and the second load from the voltage source is substantially real, and provide the determined reactive current to the voltage source.

  14. REGULATOR FOR CALUTRON ION SOURCE

    DOEpatents

    Miller, B.F.

    1958-09-01

    Improvements are described in electric discharge devices and circuits for a calutron and, more specifically, presents an arc discharge regulator circuit for the ion source of the calatron. In general, the source comprises a filament which bombards a cathode with electrons, a griid control electrode between the filament and the cathode, and an anode electrode. The control electrode has a DC potential which is varied in response to changes in the anode current flow by means of a saturable reactor installed in its power supply energizing line having the anode current flowing through its control winding. In this manner the bombardment current to the cathode may be decreased when the anode current increases beyond a predetermined level.

  15. Direct model-based predictive control scheme without cost function for voltage source inverters with reduced common-mode voltage

    NASA Astrophysics Data System (ADS)

    Kim, Jae-Chang; Moon, Sung-Ki; Kwak, Sangshin

    2018-04-01

    This paper presents a direct model-based predictive control scheme for voltage source inverters (VSIs) with reduced common-mode voltages (CMVs). The developed method directly finds optimal vectors without using repetitive calculation of a cost function. To adjust output currents with the CMVs in the range of -Vdc/6 to +Vdc/6, the developed method uses voltage vectors, as finite control resources, excluding zero voltage vectors which produce the CMVs in the VSI within ±Vdc/2. In a model-based predictive control (MPC), not using zero voltage vectors increases the output current ripples and the current errors. To alleviate these problems, the developed method uses two non-zero voltage vectors in one sampling step. In addition, the voltage vectors scheduled to be used are directly selected at every sampling step once the developed method calculates the future reference voltage vector, saving the efforts of repeatedly calculating the cost function. And the two non-zero voltage vectors are optimally allocated to make the output current approach the reference current as close as possible. Thus, low CMV, rapid current-following capability and sufficient output current ripple performance are attained by the developed method. The results of a simulation and an experiment verify the effectiveness of the developed method.

  16. Motor control for a brushless DC motor

    NASA Technical Reports Server (NTRS)

    Peterson, William J. (Inventor); Faulkner, Dennis T. (Inventor)

    1985-01-01

    This invention relates to a motor control system for a brushless DC motor having an inverter responsively coupled to the motor control system and in power transmitting relationship to the motor. The motor control system includes a motor rotor speed detecting unit that provides a pulsed waveform signal proportional to rotor speed. This pulsed waveform signal is delivered to the inverter to thereby cause an inverter fundamental current waveform output to the motor to be switched at a rate proportional to said rotor speed. In addition, the fundamental current waveform is also pulse width modulated at a rate proportional to the rotor speed. A fundamental current waveform phase advance circuit is controllingly coupled to the inverter. The phase advance circuit is coupled to receive the pulsed waveform signal from the motor rotor speed detecting unit and phase advance the pulsed waveform signal as a predetermined function of motor speed to thereby cause the fundamental current waveform to be advanced and thereby compensate for fundamental current waveform lag due to motor winding reactance which allows the motor to operate at higher speeds than the motor is rated while providing optimal torque and therefore increased efficiency.

  17. System for detecting and limiting electrical ground faults within electrical devices

    DOEpatents

    Gaubatz, Donald C.

    1990-01-01

    An electrical ground fault detection and limitation system for employment with a nuclear reactor utilizing a liquid metal coolant. Elongate electromagnetic pumps submerged within the liquid metal coolant and electrical support equipment experiencing an insulation breakdown occasion the development of electrical ground fault current. Without some form of detection and control, these currents may build to damaging power levels to expose the pump drive components to liquid metal coolant such as sodium with resultant undesirable secondary effects. Such electrical ground fault currents are detected and controlled through the employment of an isolated power input to the pumps and with the use of a ground fault control conductor providing a direct return path from the affected components to the power source. By incorporating a resistance arrangement with the ground fault control conductor, the amount of fault current permitted to flow may be regulated to the extent that the reactor may remain in operation until maintenance may be performed, notwithstanding the existence of the fault. Monitors such as synchronous demodulators may be employed to identify and evaluate fault currents for each phase of a polyphase power, and control input to the submerged pump and associated support equipment.

  18. The short-circuit current of the ileum, but not the colon, is altered in the streptozotocin diabetic rat.

    PubMed

    Forrest, Abigail; Makwana, Rajesh; Parsons, Mike

    2006-02-01

    Ion transport in control and streptozotocin-diabetic rat colon and ileum was studied using the Ussing chamber technique. No differences were observed between control and diabetic colonic mucosal short-circuit current under either basal or carbachol (100 nmol/L-1 micromol/L)-stimulated or prostaglandin E2 (100 nmol/L-1 micromol/L)-stimulated conditions. Similarly to colonic tissues, no differences in the short circuit current in either carbachol-stimulated or prostaglandin E2-stimulated tissues were observed between control and diabetic ileal mucosa. The basal diabetic ileal short circuit current (99.58 +/- 22.67 microA) was significantly greater than that of control ileal tissues (29.67 +/- 4.45 microA). This difference was abolished by the sodium-glucose-cotransporter inhibitor, phloridzin (50 micromol/L) (118.00 +/- 28.09 microA vs. 25.60 +/- 4.59 microA) and was also prevented by the replacement of glucose with mannitol in the buffer bathing the apical side of the tissue (control: 17.05 +/- 5.85 microA vs. 17.90 +/- 3.10 microA). Acetazolamide (450 micromol/L; a carbonic anhydrase inhibitor), amiloride, and bumetanide (100 micromol/L each; Na+-channel blockers), piroxicam (50 micromol/L; a COX1 cyclooxygenase inhibitor), and ouabain (1 mmol/L; a K+ transport inhibitor) had no effect on the basal short circuit current of either control or diabetic ileal tissues. This indicated that the alteration in the basal short circuit current of diabetic ileal tissues was due to a change in cellular glucose transport, whereas the evoked changes in short circuit current were unaffected by the diabetic state.

  19. Extended Constant Power Speed Range of the Brushless DC Motor Through Dual Mode Inverter Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawler, J.S.

    2000-06-23

    The trapezoidal back electromotive force (emf) brushless direct current (dc) motor (BDCM) with surface-mounted magnets has high-power density and efficiency especially when rare-earth magnet materials are used. Traction applications, such as electric vehicles, could benefit significantly from the use of such motors. Unfortunately, a practical means for driving the motor over a constant power speed ratio (CPSR) of 5:1 or more has not yet been developed. A key feature of these motors is that they have low internal inductance. The phase advance method is effective in controlling the motor power over such a speed range, but the current at highmore » speed may be several times greater than that required at the base speed. The increase in current during high-speed operation is due to the low motor inductance and the action of the bypass diodes of the inverter. The use of such a control would require increased current rating of the inverter semiconductors and additional cooling for the inverter, where the conduction losses increase proportionally with current, and especially for the motor, where the losses increase with the square of the current. The high current problems of phase advance can be mitigated by adding series inductance; however, this reduces power density, requires significant increase in supply voltage, and leaves the CPSR performance of the system highly sensitive to variations in the available voltage. A new inverter topology and control scheme has been developed that can drive low-inductance BDCMs over the CPSR that would be required in electric vehicle applications. This new controller is called the dual-mode inverter control (DMIC). It is shown that the BDCM has an infinite CPSR when it is driven by the DMIC.« less

  20. Controlling hollow relativistic electron beam orbits with an inductive current divider

    DOE PAGES

    Swanekamp, S. B.; Richardson, A. S.; Angus, J. R.; ...

    2015-02-06

    A passive method for controlling the trajectory of an intense, hollow electron beam is proposed using a vacuum structure that inductively splits the beam's return current. A central post carries a portion of the return current (I 1), while the outer conductor carries the remainder (I 2). An envelope equation appropriate for a hollow electron beam is derived and applied to the current divider. The force on the beam trajectory is shown to be proportional to (I 2-I 1), while the average force on the envelope (the beam width) is proportional to the beam current I b = (I 2more » + I 1). The values of I 1 and I 2 depend on the inductances in the return-current path geometries. Proper choice of the return-current geometries determines these inductances and offers control over the beam trajectory. As a result, solutions using realistic beam parameters show that, for appropriate choices of the return-current-path geometry, the inductive current divider can produce a beam that is both pinched and straightened so that it approaches a target at near-normal incidence with a beam diameter that is on the order of a few mm.« less

  1. The Export Administration Act: Evolution, Provisions, and Debate

    DTIC Science & Technology

    2009-07-15

    an export control classification number ( ECCN ) based on the above categories and functional group. Each ECCN is accompanied by a description of the...item and the reason for control. Currently, there are about 500 ECCN listings. In addition to discrete items on the CCL, nearly all U.S.-origin...establishment of new military end-use controls on 20 product categories consisting of 31 export control classification numbers ( ECCN ). Currently, these

  2. Jet Engine Control Using Ethernet with a BRAIN (Postprint)

    DTIC Science & Technology

    2008-07-01

    current communications may be mitigated. 15. SUBJECT TERMS BRAIN, Braided Ring Availability Integrity Network, Gas turbine, FADEC , disturbed...urrent state of the art engine controls have converged on the notion of the Full Authority Digital Engine Control ( FADEC ), which consists of a centralized...is completely dependent on the proper operation of the controller. In current systems, the FADEC is often located on the relatively cool engine fan

  3. Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Current and advanced act control system definition study. Volume 2: Appendices

    NASA Technical Reports Server (NTRS)

    Hanks, G. W.; Shomber, H. A.; Dethman, H. A.; Gratzer, L. B.; Maeshiro, A.; Gangsaas, D.; Blight, J. D.; Buchan, S. M.; Crumb, C. B.; Dorwart, R. J.

    1981-01-01

    The current status of the Active Controls Technology (ACT) for the advanced subsonic transport project is investigated through analysis of the systems technical data. Control systems technologies under examination include computerized reliability analysis, pitch axis fly by wire actuator, flaperon actuation system design trade study, control law synthesis and analysis, flutter mode control and gust load alleviation analysis, and implementation of alternative ACT systems. Extensive analysis of the computer techniques involved in each system is included.

  4. A Method of Maximum Power Control in Single-phase Utility Interactive Photovoltaic Generation System by using PWM Current Source Inverter

    NASA Astrophysics Data System (ADS)

    Neba, Yasuhiko

    This paper deals with a maximum power point tracking (MPPT) control of the photovoltaic generation with the single-phase utility interactive inverter. The photovoltaic arrays are connected by employing the PWM current source inverter to the utility. The use of the pulsating dc current and voltage allows the maximum power point to be searched. The inverter can regulate the array voltage and keep the arrays to the maximum power. This paper gives the control method and the experimental results.

  5. Response of lead-acid batteries to chopper-controlled discharge: Preliminary results

    NASA Technical Reports Server (NTRS)

    Cataldo, R. L.

    1978-01-01

    The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses up to 25 percent compared to constant current discharges at the same average discharge current of 100 amperes. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-ampere pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

  6. Response of lead-acid batteries to chopper-controlled discharge

    NASA Technical Reports Server (NTRS)

    Cataldo, R. L.

    1978-01-01

    The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses at up to 25 percent compared to constant current discharges at the same average discharge current of 100 A. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-A pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

  7. Virtual reality simulation of fuzzy-logic control during underwater dynamic positioning

    NASA Astrophysics Data System (ADS)

    Thekkedan, Midhin Das; Chin, Cheng Siong; Woo, Wai Lok

    2015-03-01

    In this paper, graphical-user-interface (GUI) software for simulation and fuzzy-logic control of a remotely operated vehicle (ROV) using MATLAB™ GUI Designing Environment is proposed. The proposed ROV's GUI platform allows the controller such as fuzzy-logic control systems design to be compared with other controllers such as proportional-integral-derivative (PID) and sliding-mode controller (SMC) systematically and interactively. External disturbance such as sea current can be added to improve the modelling in actual underwater environment. The simulated results showed the position responses of the fuzzy-logic control exhibit reasonable performance under the sea current disturbance.

  8. Adaptive control applied to Space Station attitude control system

    NASA Technical Reports Server (NTRS)

    Lam, Quang M.; Chipman, Richard; Hu, Tsay-Hsin G.; Holmes, Eric B.; Sunkel, John

    1992-01-01

    This paper presents an adaptive control approach to enhance the performance of current attitude control system used by the Space Station Freedom. The proposed control law was developed based on the direct adaptive control or model reference adaptive control scheme. Performance comparisons, subject to inertia variation, of the adaptive controller and the fixed-gain linear quadratic regulator currently implemented for the Space Station are conducted. Both the fixed-gain and the adaptive gain controllers are able to maintain the Station stability for inertia variations of up to 35 percent. However, when a 50 percent inertia variation is applied to the Station, only the adaptive controller is able to maintain the Station attitude.

  9. Optimal design strategy of switching converters employing current injected control

    NASA Astrophysics Data System (ADS)

    Lee, F. C.; Fang, Z. D.; Lee, T. H.

    1985-01-01

    This paper analyzes a buck/boost regulator employing current-injected control (CIC). It reveals the complex interactions between the dc loop and the current-injected loop and underlines the fundamental principle that governs the loop gain determination. Three commonly used compensation techniques are compared. The integral and lead/lag compensation are shown to be most desirable for performance optimization and stability.

  10. Excitation system for rotating synchronous machines

    DOEpatents

    Umans, Stephen D.; Driscoll, David J.

    2002-01-01

    A system for providing DC current to a rotating superconducting winding is provided. The system receives current feedback from the superconducting winding and determines an error signal based on the current feedback and a reference signal. The system determines a control signal corresponding to the error signal and provides a positive and negative superconducting winding excitation voltage based on the control signal.

  11. Symmetric voltage-controlled variable resistance

    NASA Technical Reports Server (NTRS)

    Vanelli, J. C.

    1978-01-01

    Feedback network makes resistance of field-effect transistor (FET) same for current flowing in either direction. It combines control voltage with source and load voltages to give symmetric current/voltage characteristics. Since circuit produces same magnitude output voltage for current flowing in either direction, it introduces no offset in presense of altering polarity signals. It is therefore ideal for sensor and effector circuits in servocontrol systems.

  12. The Mineralogy of Microbiologically Influenced Corrosion

    DTIC Science & Technology

    2015-01-01

    cathodically active). The biomineralization rate and the corrosion current control oxide accumulation. Localized corrosion current that exceeds the... phosphate ). Localized corrosion would not readily occur unless Cl- was the predominant anion in the medium. They concluded that the Cl- concentration...transforms into goethite and/or hematite over time. For mild steel corrosion under anodic control , manganese oxides elevate con-osion current, but will

  13. Research of vibration control based on current mode piezoelectric shunt damping circuit

    NASA Astrophysics Data System (ADS)

    Liu, Weiwei; Mao, Qibo

    2017-12-01

    The piezoelectric shunt damping circuit using current mode approach is imposed to control the vibration of a cantilever beam. Firstly, the simulated inductance with large values are designed for the corresponding RL series shunt circuits. Moreover, with an example of cantilever beam, the second natural frequency of the beam is targeted to control for experiment. By adjusting the values of the equivalent inductance and equivalent resistance of the shunt circuit, the optimal damping of the shunt circuit is obtained. Meanwhile, the designed piezoelectric shunt damping circuit stability is experimental verified. Experimental results show that the proposed piezoelectric shunt damping circuit based on current mode circuit has good vibration control performance. However, the control performance will be reduced if equivalent inductance and equivalent resistance values deviate from optimal values.

  14. Cognitive impairments in poly-drug ketamine users.

    PubMed

    Liang, H J; Lau, C G; Tang, A; Chan, F; Ungvari, G S; Tang, W K

    2013-11-01

    Cognitive impairment has been found to be reversible in people with substance abuse, particularly those using ketamine. Ketamine users are often poly-substance users. This study compared the cognitive functions of current and former ketamine users who were also abusing other psychoactive substances with those of non-users of illicit drugs as controls. One hundred ketamine poly-drug users and 100 controls were recruited. Drug users were divided into current (n = 32) and ex-users (n = 64) according to the duration of abstinence from ketamine (>30 days). The Beck Depression Inventory (BDI), the Hospital Anxiety Depression Scale (HADSA) and the Severity of Dependence Scale (SDS) were used to evaluate depression and anxiety symptoms and the severity of drug use, respectively. The cognitive test battery comprised verbal memory (Wechsler Memory Scale III: Logic Memory and Word List), visual memory (Rey-Osterrieth Complex Figure, ROCF), executive function (Stroop, Wisconsin Card Sorting Test, and Modified Verbal Fluency Test), working memory (Digit Span Backward), and general intelligence (Information, Arithmetic and Digit-Symbol Coding) tests. Current users had higher BDI and HADSA scores than ex-users (p < 0.001 for BDI and p = 0.022 for HADSA) and controls (p < 0.001 for BDI and p = 0.002 for HADSA). Ex-users had higher BDI (p = 0.006) but equal HADSA scores (p = 1.000) compared to controls. Both current and ex-users had lower scores on Logical Memory delayed recall (p = 0.038 for current users and p = 0.032 for ex-users) and ROCF delayed recall (p = 0.033 for current users and p = 0.014 for ex-users) than controls. Current users also performed worse on ROCF recognition than controls (p = 0.002). No difference was found between the cognitive functions of current and ex-users. Ketamine poly-drug users displayed predominantly verbal and visual memory impairments, which persisted in ex-users. The interactive effect of ketamine and poly-drug use on memory needs further investigation. © 2013 Elsevier Ltd. All rights reserved.

  15. Direct Current Amplifier. Report No. 92; AMPLIFICADOR DE CORRIENTE CONTINUA. Informe No. 92

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marazzi, C.

    1963-01-01

    A direct-current amplifier with low zero current and solid-state chopper for input is described. This amplifier can be used in control circuits and for general applications such as temperature measurement in thermocouples, amplifier for a photo-sensitive element, or zero amplifier in control systems. The input impedance is relatively low, serving principally as current amplifier. It is possible to obtain a symmetry characteristic for positive and negative values of the output voltage with respect to the input. (tr-auth)

  16. Method for controlling gas metal arc welding

    DOEpatents

    Smartt, Herschel B.; Einerson, Carolyn J.; Watkins, Arthur D.

    1989-01-01

    The heat input and mass input in a Gas Metal Arc welding process are controlled by a method that comprises calculating appropriate values for weld speed, filler wire feed rate and an expected value for the welding current by algorithmic function means, applying such values for weld speed and filler wire feed rate to the welding process, measuring the welding current, comparing the measured current to the calculated current, using said comparison to calculate corrections for the weld speed and filler wire feed rate, and applying corrections.

  17. Surge current and electron swarm tunnel tests of thermal blanket and ground strap materials

    NASA Technical Reports Server (NTRS)

    Hoffmaster, D. K.; Inouye, G. T.; Sellen, J. M., Jr.

    1977-01-01

    The results are described of a series of current conduction tests with a thermal control blanket to which grounding straps have been attached. The material and the ground strap attachment procedure are described. The current conduction tests consisted of a surge current examination of the ground strap and a dilute flow, energetic electron deposition and transport through the bulk of the insulating film of this thermal blanket material. Both of these test procedures were used previously with thermal control blanket materials.

  18. Response of nickel to zinc cells to electric vehicle chopper discharge waveforms

    NASA Technical Reports Server (NTRS)

    Cataldo, R. L.

    1981-01-01

    The preliminary results of simulated electric vehicle chopper controlled discharge of a Nickel/Zinc battery shows delivered energy increases of 5 to 25 percent compared to constant current discharges of the same average current. The percentage increase was a function of chopper frequency, the ratio of peak to average current, and the magnitude of the discharge current. Because the chopper effects are of a complex nature, electric vehicle battery/speed controller interaction must be carefully considered in vehicle design to optimize battery performance.

  19. Methods, systems and apparatus for synchronous current regulation of a five-phase machine

    DOEpatents

    Gallegos-Lopez, Gabriel; Perisic, Milun

    2012-10-09

    Methods, systems and apparatus are provided for controlling operation of and regulating current provided to a five-phase machine when one or more phases has experienced a fault or has failed. In one implementation, the disclosed embodiments can be used to synchronously regulate current in a vector controlled motor drive system that includes a five-phase AC machine, a five-phase inverter module coupled to the five-phase AC machine, and a synchronous current regulator.

  20. A Hybrid Nonlinear Control Scheme for Active Magnetic Bearings

    NASA Technical Reports Server (NTRS)

    Xia, F.; Albritton, N. G.; Hung, J. Y.; Nelms, R. M.

    1996-01-01

    A nonlinear control scheme for active magnetic bearings is presented in this work. Magnet winding currents are chosen as control inputs for the electromechanical dynamics, which are linearized using feedback linearization. Then, the desired magnet currents are enforced by sliding mode control design of the electromagnetic dynamics. The overall control scheme is described by a multiple loop block diagram; the approach also falls in the class of nonlinear controls that are collectively known as the 'integrator backstepping' method. Control system hardware and new switching power electronics for implementing the controller are described. Various experiments and simulation results are presented to demonstrate the concepts' potentials.

  1. Controller for computer control of brushless dc motors. [automobile engines

    NASA Technical Reports Server (NTRS)

    Hieda, L. S. (Inventor)

    1981-01-01

    A motor speed and torque controller for brushless d.c. motors provides an unusually smooth torque control arrangement. The controller provides a means for controlling a current waveform in each winding of a brushless dc motor by synchronization of an excitation pulse train from a programmable oscillator. Sensing of torque for synchronization is provided by a light beam chopper mounted on the motor rotor shaft. Speed and duty cycle are independently controlled by controlling the frequency and pulse width output of the programmable oscillator. A means is also provided so that current transitions from one motor winding to another is effected without abrupt changes in output torque.

  2. Circuit engineering principles for construction of bipolar large-scale integrated circuit storage devices and very large-scale main memory

    NASA Astrophysics Data System (ADS)

    Neklyudov, A. A.; Savenkov, V. N.; Sergeyez, A. G.

    1984-06-01

    Memories are improved by increasing speed or the memory volume on a single chip. The most effective means for increasing speeds in bipolar memories are current control circuits with the lowest extraction times for a specific power consumption (1/4 pJ/bit). The control current circuitry involves multistage current switches and circuits accelerating transient processes in storage elements and links. Circuit principles for the design of bipolar memories with maximum speeds for an assigned minimum of circuit topology are analyzed. Two main classes of storage with current control are considered: the ECL type and super-integrated injection type storage with data capacities of N = 1/4 and N 4/16, respectively. The circuits reduce logic voltage differentials and the volumes of lexical and discharge buses and control circuit buses. The limiting speed is determined by the antiinterference requirements of the memory in storage and extraction modes.

  3. Core Training in Low Back Disorders: Role of the Pilates Method.

    PubMed

    Joyce, Andrew A; Kotler, Dana H

    The Pilates method is a system of exercises developed by Joseph Pilates, which emphasizes recruitment and strengthening of the core muscles, flexibility, and breathing, to promote stability and control of movement. Its focus bears similarity to current evidence-based exercise programs for low back disorders. Spinal stability is a function of three interdependent systems, osseoligamentous, muscular, and neural control; exercise addresses both the muscular and neural function. The "core" typically refers to the muscular control required to maintain functional stability. Prior research has highlighted the importance of muscular strength and recruitment, with debate over the importance of individual muscles in the wider context of core control. Though developed long before the current evidence, the Pilates method is relevant in this setting and clearly relates to current evidence-based exercise interventions. Current literature supports the Pilates method as a treatment for low back disorders, but its benefit when compared with other exercise is less clear.

  4. System and method for bearing fault detection using stator current noise cancellation

    DOEpatents

    Zhou, Wei; Lu, Bin; Habetler, Thomas G.; Harley, Ronald G.; Theisen, Peter J.

    2010-08-17

    A system and method for detecting incipient mechanical motor faults by way of current noise cancellation is disclosed. The system includes a controller configured to detect indicia of incipient mechanical motor faults. The controller further includes a processor programmed to receive a baseline set of current data from an operating motor and define a noise component in the baseline set of current data. The processor is also programmed to repeatedly receive real-time operating current data from the operating motor and remove the noise component from the operating current data in real-time to isolate any fault components present in the operating current data. The processor is then programmed to generate a fault index for the operating current data based on any isolated fault components.

  5. Control strategy based on SPWM switching patterns for grid connected photovoltaic inverter

    NASA Astrophysics Data System (ADS)

    Hassaine, L.; Mraoui, A.

    2017-02-01

    Generally, for lower installation of photovoltaic systems connected to the grid, pulse width modulation (PWM) is a widely used technique for controlling the voltage source inverters injects currents into the grid. The current injected must be sinusoidal with reduced harmonic distortion. In this paper, a digital implementation of a control strategy based on PWM switching patterns for an inverter for photovoltaic system connected to the grid is presented. This strategy synchronize a sinusoidal inverter output current with a grid voltage The digital implementation of the proposed PWM switching pattern when is compared with the conventional one exhibit the advantage: Simplicity, reduction of the memory requirements and power calculation for the control

  6. Innovation for Pollution Control

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Kinetic Controls Inc.'s refuse-fired steam generating facility led to the development of an air pollution equipment control device. The device is currently marketed by two NASA/Langley Research Center employees. It automatically senses and compensates for the changes in smoke composition when refuse is used as a fuel by adjusting the precipitator's voltage and current to permit maximum collection of electrically charged dust particles. The control adapts to any electrostatic precipitator and should have extensive commercial applications.

  7. Training Course for Power Operating Personnel. Lesson No. 6: Alternating-Current Generator Excitation.

    ERIC Educational Resources Information Center

    Department of the Interior, Denver, CO. Engineering and Research Center.

    Subjects covered in this text are controlling the hydroelectric generator, generator excitation, basic principles of direct current generation, direction of current flow, basic alternating current generator, alternating and direct current voltage outputs, converting alternating current to direct current, review of the basic generator and…

  8. The Effect of the California Tobacco Control Program on Smoking Prevalence, Cigarette Consumption, and Healthcare Costs: 1989–2008

    PubMed Central

    Lightwood, James; Glantz, Stanton A.

    2013-01-01

    Background Previous research has shown that tobacco control funding in California has reduced per capita cigarette consumption and per capita healthcare expenditures. This paper refines our earlier model by estimating the effect of California tobacco control funding on current smoking prevalence and cigarette consumption per smoker and the effect of prevalence and consumption on per capita healthcare expenditures. The results are used to calculate new estimates of the effect of the California Tobacco Program. Methodology/Principal Findings Using state-specific aggregate data, current smoking prevalence and cigarette consumption per smoker are modeled as functions of cumulative California and control states' per capita tobacco control funding, cigarette price, and per capita income. Per capita healthcare expenditures are modeled as a function of prevalence of current smoking, cigarette consumption per smoker, and per capita income. One additional dollar of cumulative per capita tobacco control funding is associated with reduction in current smoking prevalence of 0.0497 (SE.00347) percentage points and current smoker cigarette consumption of 1.39 (SE.132) packs per smoker per year. Reductions of one percentage point in current smoking prevalence and one pack smoked per smoker are associated with $35.4 (SE $9.85) and $3.14 (SE.786) reductions in per capita healthcare expenditure, respectively (2010 dollars), using the National Income and Product Accounts (NIPA) measure of healthcare spending. Conclusions/Significance Between FY 1989 and 2008 the California Tobacco Program cost $2.4 billion and led to cumulative NIPA healthcare expenditure savings of $134 (SE $30.5) billion. PMID:23418411

  9. Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Current and advanced act control system definition study, volume 1

    NASA Technical Reports Server (NTRS)

    Hanks, G. W.; Shomber, H. A.; Dethman, H. A.; Gratzer, L. B.; Maeshiro, A.; Gangsaas, D.; Blight, J. D.; Buchan, S. M.; Crumb, C. B.; Dorwart, R. J.

    1981-01-01

    An active controls technology (ACT) system architecture was selected based on current technology system elements and optimal control theory was evaluated for use in analyzing and synthesizing ACT multiple control laws. The system selected employs three redundant computers to implement all of the ACT functions, four redundant smaller computers to implement the crucial pitch-augmented stability function, and a separate maintenance and display computer. The reliability objective of probability of crucial function failure of less than 1 x 10 to the -9th power per flight of 1 hr can be met with current technology system components, if the software is assumed fault free and coverage approaching 1.0 can be provided. The optimal control theory approach to ACT control law synthesis yielded comparable control law performance much more systematically and directly than the classical s-domain approach. The ACT control law performance, although somewhat degraded by the inclusion of representative nonlinearities, remained quite effective. Certain high-frequency gust-load alleviation functions may require increased surface rate capability.

  10. Controlling electrode gap during vacuum arc remelting at low melting current

    DOEpatents

    Williamson, Rodney L.; Zanner, Frank J.; Grose, Stephen M.

    1997-01-01

    An apparatus and method for controlling electrode gap in a vacuum arc remelting furnace, particularly at low melting currents. Spectrographic analysis is performed of the metal vapor plasma, from which estimates of electrode gap are derived.

  11. Automatic method of measuring silicon-controlled-rectifier holding current

    NASA Technical Reports Server (NTRS)

    Maslowski, E. A.

    1972-01-01

    Development of automated silicon controlled rectifier circuit for measuring minimum anode current required to maintain rectifiers in conducting state is discussed. Components of circuit are described and principles of operation are explained. Illustration of circuit is provided.

  12. Parental communication style and family relationships in children of bipolar parents.

    PubMed

    Vance, Yvonne H; Huntley Jones, Steven; Espie, Jonathan; Bentall, Richard; Tai, Sara

    2008-09-01

    To examine relationships between parental communication styles and family environment in parents with bipolar disorder (BD) and their children (CBP). On measures of parental communication styles and family environment, 20 BD parents and their 23 children (CBP) were compared to controls. Children completed a current mood measure. BD parents endorsed more negative communication styles and were less expressive than controls. CBP presented with more current or lifetime mood disorder diagnoses than control children (CC). Current depressive mood was associated with different perceptions of family environment for both CBP and CC. This familial high risk design indicated differences in family environment, parenting style, and in children of bipolar parents' perception of their family environment as it relates to their current mood.

  13. Musculoskeletal morbidity: the growing burden of shoulder pain and disability and poor quality of life in diabetic outpatients.

    PubMed

    Laslett, L L; Burnet, S P; Jones, J A; Redmond, C L; McNeil, J D

    2007-01-01

    To investigate shoulder pain and disability and quality of life (QoL) over 12 months in patients with diabetes and in a non-diabetic control group. Cross-sectional study with 12-month follow-up in diabetic (n=189) and medical (n=99) outpatients employing the Shoulder Pain and Disability Index (SPADI) and SF-36 version 2. The results were analysed using restricted maximum likelihood (REML). The prevalence of current shoulder symptoms was 35% in diabetics and 17% in controls. Shoulder pain and disability as calculated by the SPADI were independently associated with diabetes (vs controls) and current shoulder symptoms, and worsened over 12 months. Disability scores worsened with age in diabetics, and pain scores were higher in diabetics than controls among patients reporting current shoulder symptoms. Poor physical QoL worsened over time in patients with diabetes and was worse in patients with current shoulder symptoms, whether they had diabetes or not. Mental QoL was worse only in patients with current shoulder symptoms. Shoulder symptoms are common, affecting 1 in every 3 diabetic patients and 1 in every 6 control patients. In this study shoulder pain, disability and physical QoL were poorer among diabetics and patients reporting current shoulder symptoms, and worsened over time. Mental QoL was worse in patients reporting current shoulder symptoms and was independent of diabetes. Therefore, shoulder symptoms are common, are associated with poor physical and mental QoL in addition to shoulder pain and disability, and are worse in patients with diabetes, even in a population with relatively moderate shoulder pain and disability.

  14. Error processing in current and former cocaine users

    PubMed Central

    Castelluccio, Brian C.; Meda, Shashwath A.; Muska, Christine E.; Stevens, Michael C.; Pearlson, Godfrey D.

    2013-01-01

    Deficits in response inhibition and error processing can result in maladaptive behavior, including failure to use past mistakes to inform present decisions. A specific deficit in inhibiting a prepotent response represents one aspect of impulsivity and is a prominent feature of addictive behaviors in general, including cocaine abuse/dependence. Brain regions implicated in cognitive control exhibit reduced activation in cocaine abusers. The purposes of the present investigation were (1) to identify neural differences associated with error processing in current and former cocaine-dependent individuals compared to healthy controls and (2) to determine whether former, long-term abstinent cocaine users showed similar differences compared with current users. The present study used an fMRI Go/No-Go task to investigate differences in BOLD response to correct rejections and false alarms between current cocaine users (n=30), former cocaine users (n=29), and healthy controls (n=35). Impulsivity trait measures were also assessed and compared with BOLD activity. Nineteen regions of interest previously implicated in errors of disinhibition were queried. There were no group differences in the correct rejections condition, but both current and former users exhibited increased BOLD response relative to controls for false alarms. In current users, the pregenual cingulate gyrus and left angular/supramarginal gyri overactivated. In former users, the right middle frontal/precentral gyri, right inferior parietal lobule, and left angular/supramarginal gyri overactivated. Overall, our results support a hypothesis that neural activity in former users differs more from healthy controls than that of current users due to cognitive compensation that facilitates abstinence. PMID:23949893

  15. Associations of Trying to Lose Weight, Weight Control Behaviors, and Current Cigarette Use among US High School Students

    ERIC Educational Resources Information Center

    Johnson, Jonetta L.; Eaton, Danice K.; Pederson, Linda L.; Lowry, Richard

    2009-01-01

    Background: Approximately one-quarter of high school students currently use cigarettes. Previous research has suggested some youth use smoking as a method for losing weight. The purpose of this study was to describe the association of current cigarette use with specific healthy and unhealthy weight control practices among 9th-12th grade students…

  16. Digital control of diode laser for atmospheric spectroscopy

    NASA Technical Reports Server (NTRS)

    Menzies, R. T.; Rutledge, C. W. (Inventor)

    1985-01-01

    A system is described for remote absorption spectroscopy of trace species using a diode laser tunable over a useful spectral region of 50 to 200 cm(-1) by control of diode laser temperature over range from 15 K to 100 K, and tunable over a smaller region of typically 0.1 to 10 cm(-1) by control of the diode laser current over a range from 0 to 2 amps. Diode laser temperature and current set points are transmitted to the instrument in digital form and stored in memory for retrieval under control of a microprocessor during measurements. The laser diode current is determined by a digital to analog converter through a field effect transistor for a high degree of ambient temperature stability, while the laser diode temperature is determined by set points entered into a digital to analog converter under control of the microprocessor. Temperature of the laser diode is sensed by a sensor diode to provide negative feedback to the temperature control circuit that responds to the temperature control digital to analog converter.

  17. Extended Task Space Control for Robotic Manipulators

    NASA Technical Reports Server (NTRS)

    Backes, Paul G. (Inventor); Long, Mark K. (Inventor)

    1996-01-01

    The invention is a method of operating a robot in successive sampling intervals to perform a task, the robot having joints and joint actuators with actuator control loops, by decomposing the task into behavior forces, accelerations, velocities and positions of plural behaviors to be exhibited by the robot simultaneously, computing actuator accelerations of the joint actuators for the current sampling interval from both behavior forces, accelerations velocities and positions of the current sampling interval and actuator velocities and positions of the previous sampling interval, computing actuator velocities and positions of the joint actuators for the current sampling interval from the actuator velocities and positions of the previous sampling interval, and, finally, controlling the actuators in accordance with the actuator accelerations, velocities and positions of the current sampling interval. The actuator accelerations, velocities and positions of the current sampling interval are stored for use during the next sampling interval.

  18. Thermal transistor utilizing gas-liquid transition.

    PubMed

    Komatsu, Teruhisa S; Ito, Nobuyasu

    2011-01-01

    We propose a simple thermal transistor, a device to control heat current. In order to effectively change the current, we utilize the gas-liquid transition of the heat-conducting medium (fluid) because the gas region can act as a good thermal insulator. The three terminals of the transistor are located at both ends and the center of the system, and are put into contact with distinct heat baths. The key idea is a special arrangement of the three terminals. The temperature at one end (the gate temperature) is used as an input signal to control the heat current between the center (source, hot) and another end (drain, cold). Simulating the nanoscale systems of this transistor, control of heat current is demonstrated. The heat current is effectively cut off when the gate temperature is cold and it flows normally when it is hot. By using an extended version of this transistor, we also simulate a primitive application for an inverter.

  19. Closed-loop torque feedback for a universal field-oriented controller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Doncker, R.W.A.A.; King, R.D.; Sanza, P.C.

    A torque feedback system is employed in a universal field-oriented (UFO) controller to tune a torque-producing current command and a slip frequency command in order to achieve robust torque control of an induction machine even in the event of current regulator errors and during transitions between pulse width modulated (PWM) and square wave modes of operation. 1 figure.

  20. Closed-loop torque feedback for a universal field-oriented controller

    DOEpatents

    De Doncker, R.W.A.A.; King, R.D.; Sanza, P.C.; Haefner, K.B.

    1992-11-24

    A torque feedback system is employed in a universal field-oriented (UFO) controller to tune a torque-producing current command and a slip frequency command in order to achieve robust torque control of an induction machine even in the event of current regulator errors and during transitions between pulse width modulated (PWM) and square wave modes of operation. 1 figure.

  1. Closed-loop torque feedback for a universal field-oriented controller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Doncker, Rik W. A. A.; King, Robert D.; Sanza, Peter C.

    A torque feedback system is employed in a universal field-oriented (UFO) controller to tune a torque-producing current command and a slip frequency command in order to achieve robust torque control of an induction machine even in the event of current regulator errors and during transitions between pulse width modulated (PWM) and square wave modes of operation.

  2. 77 FR 41785 - Information Collection Being Submitted for Review and Approval to the Office of Management and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-16

    ... currently valid control number. No person shall be subject to any penalty for failing to comply with a collection of information subject to the PRA that does not display a valid control number. Comments are... currently valid control number. No person shall be subject to any penalty for failing to comply with a...

  3. 78 FR 13876 - Information Collection Being Submitted for Review and Approval to the Office of Management and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-01

    ... currently valid control number. No person shall be subject to any penalty for failing to comply with a collection of information subject to the PRA that does not display a valid control number. Comments are... currently valid control number. No person shall be subject to any penalty for failing to comply with a...

  4. Plasma Charge Current for Controlling and Monitoring Electron Beam Welding with Beam Oscillation

    PubMed Central

    Trushnikov, Dmitriy; Belenkiy, Vladimir; Shchavlev, Valeriy; Piskunov, Anatoliy; Abdullin, Aleksandr; Mladenov, Georgy

    2012-01-01

    Electron beam welding (EBW) shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which substantially limits the operation speed of these systems and has a negative effect on weld joint quality. The purpose of this study is to develop a method for operational control of the electron beam focus during welding in the deep penetration mode. The method uses the plasma charge current signal as an additional informational parameter. This parameter allows identification of the electron beam focus regime in electron-beam welding without application of additional low-frequency scanning of focus. It can be used for working out operational electron beam control methods focusing exactly on the welding. In addition, use of this parameter allows one to observe the shape of the keyhole during the welding process. PMID:23242276

  5. A novel four-bar linkage prosthetic knee based on magnetorheological effect: principle, structure, simulation and control

    NASA Astrophysics Data System (ADS)

    Xu, Lei; Wang, Dai-Hua; Fu, Qiang; Yuan, Gang; Hu, Lei-Zi

    2016-11-01

    In this paper, the principle and structure of the four-bar linkage prosthetic knee based on the magnetorheological effect (FLPKME) are proposed and realized by individually integrating the upper and lower link rods of the four-bar linkage with the piston rod and the outer cylinder of the magnetorheological (MR) damper. The integrated MR damper, in which the MR fluid is operated in the shear mode, has a double-ended structure. The prototype of the FLPKME is designed and fabricated. Utilizing the developed FLPKME, the lower limb prosthesis is developed, modeled, and simulated. On these bases, the control algorithm for the FLPKME is developed. A test platform for the FLPKME is developed and the performance of the FLPKME with seven constant currents and controlled currents by the control algorithm developed in this paper are experimentally tested. The results show that the FLPKME with a constant current of 1.6 A possesses the basic stable gait, and the FLPKME with the controlled currents by the control algorithm developed in this paper is able to track the motions well and to imitate the natural motions of a healthy human knee joint.

  6. Plasma charge current for controlling and monitoring electron beam welding with beam oscillation.

    PubMed

    Trushnikov, Dmitriy; Belenkiy, Vladimir; Shchavlev, Valeriy; Piskunov, Anatoliy; Abdullin, Aleksandr; Mladenov, Georgy

    2012-12-14

    Electron beam welding (EBW) shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which substantially limits the operation speed of these systems and has a negative effect on weld joint quality. The purpose of this study is to develop a method for operational control of the electron beam focus during welding in the deep penetration mode. The method uses the plasma charge current signal as an additional informational parameter. This parameter allows identification of the electron beam focus regime in electron-beam welding without application of additional low-frequency scanning of focus. It can be used for working out operational electron beam control methods focusing exactly on the welding. In addition, use of this parameter allows one to observe the shape of the keyhole during the welding process.

  7. Driver electronics design and control for a total artificial heart linear motor.

    PubMed

    Unthan, Kristin; Cuenca-Navalon, Elena; Pelletier, Benedikt; Finocchiaro, Thomas; Steinseifer, Ulrich

    2018-01-27

    For any implantable device size and efficiency are critical properties. Thus, a linear motor for a Total Artificial Heart was optimized with focus on driver electronics and control strategies. Hardware requirements were defined from power supply and motor setup. Four full bridges were chosen for the power electronics. Shunt resistors were set up for current measurement. Unipolar and bipolar switching for power electronics control were compared regarding current ripple and power losses. Here, unipolar switching showed smaller current ripple and required less power to create the necessary motor forces. Based on calculations for minimal power losses Lorentz force was distributed to the actor's four coils. The distribution was determined as ratio of effective magnetic flux through each coil, which was captured by a force test rig. Static and dynamic measurements under physiological conditions analyzed interaction of control and hardware and all efficiencies were over 89%. In conclusion, the designed electronics, optimized control strategy and applied current distribution create the required motor force and perform optimal under physiological conditions. The developed driver electronics and control offer optimized size and efficiency for any implantable or portable device with multiple independent motor coils. Graphical Abstract ᅟ.

  8. Costs and cost-efficacy analysis of the 2014 GESIDA/Spanish National AIDS Plan recommended guidelines for initial antiretroviral therapy in HIV-infected adults.

    PubMed

    Blasco, Antonio Javier; Llibre, Josep M; Berenguer, Juan; González-García, Juan; Knobel, Hernando; Lozano, Fernando; Podzamczer, Daniel; Pulido, Federico; Rivero, Antonio; Tuset, Montserrat; Lázaro, Pablo; Gatell, Josep M

    2015-03-01

    GESIDA and the National AIDS Plan panel of experts suggest preferred (PR) and alternative (AR) regimens of antiretroviral treatment (ART) as initial therapy in HIV-infected patients for 2014. The objective of this study is to evaluate the costs and the efficiency of initiating treatment with these regimens. An economic assessment was made of costs and efficiency (cost/efficacy) based on decision tree analyses. Efficacy was defined as the probability of reporting a viral load <50 copies/mL at week 48, in an intention-to-treat analysis. Cost of initiating treatment with an ART regimen was defined as the costs of ART and its consequences (adverse effects, changes of ART regimen, and drug resistance studies) during the first 48 weeks. The payer perspective (National Health System) was applied by considering only differential direct costs: ART (official prices), management of adverse effects, studies of resistance, and HLA B*5701 testing. The setting is Spain and costs correspond to those of 2014. A sensitivity deterministic analysis was conducted, building three scenarios for each regimen: base case, most favourable and least favourable. In the base case scenario, the cost of initiating treatment ranges from 5133 Euros for ABC/3TC+EFV to 11,949 Euros for TDF/FTC+RAL. The efficacy varies between 0.66 for ABC/3TC+LPV/r and ABC/3TC+ATV/r, and 0.89 for TDF/FTC/EVG/COBI. Efficiency, in terms of cost/efficacy, ranges from 7546 to 13,802 Euros per responder at 48 weeks, for ABC/3TC+EFV and TDF/FTC+RAL respectively. Considering ART official prices, the most efficient regimen was ABC/3TC+EFV (AR), followed by the non-nucleoside containing PR (TDF/FTC/RPV and TDF/FTC/EFV). The sensitivity analysis confirms the robustness of these findings. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  9. Generation of infectious feline immunodeficiency virus (FIV) encoding FIV/human immunodeficiency virus chimeric protease.

    PubMed

    Lin, Ying-Chuan; Torbett, Bruce E; Elder, John H

    2010-07-01

    Feline immunodeficiency virus (FIV) and human immunodeficiency virus type 1 (HIV-1) proteases (PRs) share only 23% amino acid identity and exhibit distinct specificities yet have very similar 3-dimensional structures. Chimeric PRs in which HIV residues were substituted in structurally equivalent positions in FIV PR were prepared in order to study the molecular basis of PR specificity. Previous in vitro analyses showed that such substitutions dramatically altered the inhibitor specificity of mutant PRs but changed the rate and specificity of Gag cleavage so that chimeric FIVs were not infectious. Chimeric PRs encoding combinations of the I37V, N55M, M56I, V59I, L97T, I98P, Q99V, and P100N mutations were cloned into FIV Gag-Pol, and those constructs that best approximated the temporal cleavage pattern generated by wild-type FIV PR, while maintaining HIV-like inhibitor specificity, were selected. Two mutations, M56I and L97T, were intolerant to change and caused inefficient cleavage at NC-p2. However, a mutant PR with six substitutions (I37V, N55M, V59I, I98P, Q99V, and P100N) was selected and placed in the context of full-length FIV-34TF10. This virus, termed YCL6, had low-level infectivity ex vivo, and after passage, progeny that exhibited a higher growth rate emerged. The residue at the position of one of the six mutations, I98P, further mutated on passage to either P98H or P98S. Both PRs were sensitive to the HIV-1 PR inhibitors lopinavir (LPV) and darunavir (DRV), as well as to the broad-based inhibitor TL-3, with 50% inhibitory concentrations (IC(50)) of 30 to 40 nM, consistent with ex vivo results obtained using mutant FIVs. The chimeras offer an infectivity system with which to screen compounds for potential as broad-based PR inhibitors, define structural parameters that dictate specificity, and investigate pathways for drug resistance development.

  10. Generation of Infectious Feline Immunodeficiency Virus (FIV) Encoding FIV/Human Immunodeficiency Virus Chimeric Protease▿

    PubMed Central

    Lin, Ying-Chuan; Torbett, Bruce E.; Elder, John H.

    2010-01-01

    Feline immunodeficiency virus (FIV) and human immunodeficiency virus type 1 (HIV-1) proteases (PRs) share only 23% amino acid identity and exhibit distinct specificities yet have very similar 3-dimensional structures. Chimeric PRs in which HIV residues were substituted in structurally equivalent positions in FIV PR were prepared in order to study the molecular basis of PR specificity. Previous in vitro analyses showed that such substitutions dramatically altered the inhibitor specificity of mutant PRs but changed the rate and specificity of Gag cleavage so that chimeric FIVs were not infectious. Chimeric PRs encoding combinations of the I37V, N55M, M56I, V59I, L97T, I98P, Q99V, and P100N mutations were cloned into FIV Gag-Pol, and those constructs that best approximated the temporal cleavage pattern generated by wild-type FIV PR, while maintaining HIV-like inhibitor specificity, were selected. Two mutations, M56I and L97T, were intolerant to change and caused inefficient cleavage at NC-p2. However, a mutant PR with six substitutions (I37V, N55M, V59I, I98P, Q99V, and P100N) was selected and placed in the context of full-length FIV-34TF10. This virus, termed YCL6, had low-level infectivity ex vivo, and after passage, progeny that exhibited a higher growth rate emerged. The residue at the position of one of the six mutations, I98P, further mutated on passage to either P98H or P98S. Both PRs were sensitive to the HIV-1 PR inhibitors lopinavir (LPV) and darunavir (DRV), as well as to the broad-based inhibitor TL-3, with 50% inhibitory concentrations (IC50) of 30 to 40 nM, consistent with ex vivo results obtained using mutant FIVs. The chimeras offer an infectivity system with which to screen compounds for potential as broad-based PR inhibitors, define structural parameters that dictate specificity, and investigate pathways for drug resistance development. PMID:20410281

  11. Thai national guidelines for the prevention of mother-to-child transmission of human immunodeficiency virus 2017

    PubMed Central

    Lolekha, Rangsima; Chokephaibulkit, Kulkanya; Phanuphak, Nittaya; Chaithongwongwatthana, Surasith; Kiertiburanakul, Sasisopin; Chetchotisakd, Pleonchan; Boonsuk, Sarawut

    2018-01-01

    Background Thailand has made progress in reducing perinatal HIV transmission rates to levels that meet the World Health Organization targets for so-called “elimination” (<2%) of mother-to-child transmission (MTCT). Objectives To highlight the Thailand National Guidelines on HIV/AIDS Treatment Prevention Working Group issued a new version of its National Prevention of MTCT guidelines in March 2017 aimed to reduce MTCT rate to <1% by 2020. Discussion of guidelines The guidelines include recommending initiation of antepartum antiretroviral therapy (ART) containing tenofovir disoproxil fumarate (TDF) plus lamivudine (3TC)/emtricitabine (FTC) plus efavirenz regardless of CD4 cell count as soon as HIV is diagnosed for ART naïve HIV-infected pregnant women. An alternative regimen is TDF or zidovudine (AZT) plus 3TC/FTC plus lopinavir/ritonavir (LPV/r) for HIV-infected pregnant women suspected resistant to non-nucleoside reverse transcriptase inhibitors. Treatment should be started immediately irrespective of gestational age and continued after delivery for life. Raltegravir is recommended in addition to the ART regimen for HIV-infected pregnant women who present late (gestational age (GA) ≥32 weeks) or those who have a viral load (VL) >1000 copies/mL at GA ≥32 weeks. HIV-infected pregnant women who conceive while receiving ART should continue their treatment regimen during pregnancy. HIV-infected pregnant women who present in labor and are not receiving ART should receive single-dose nevirapine immediately along with oral AZT, and continue ART for life. Infants born to HIV-infected mothers are categorized as high or standard risk for MTCT. High MTCT risk is defined as an infant whose mother has a viral load (VL) > 50 copies/mL at GA > 36 weeks or has received ART <12 weeks before delivery, or has poor ART adherence. These infants should be started on AZT plus 3TC plus NVP for 6 weeks after delivery. Infants with standard MTCT risk should receive AZT for 4 weeks. Formula feeding exclusively is recommended for all HIV-exposed infants. PMID:29861798

  12. Control and protection system for paralleled modular static inverter-converter systems

    NASA Technical Reports Server (NTRS)

    Birchenough, A. G.; Gourash, F.

    1973-01-01

    A control and protection system was developed for use with a paralleled 2.5-kWe-per-module static inverter-converter system. The control and protection system senses internal and external fault parameters such as voltage, frequency, current, and paralleling current unbalance. A logic system controls contactors to isolate defective power conditioners or loads. The system sequences contactor operation to automatically control parallel operation, startup, and fault isolation. Transient overload protection and fault checking sequences are included. The operation and performance of a control and protection system, with detailed circuit descriptions, are presented.

  13. Electric control of emergent magnonic spin current and dynamic multiferroicity in magnetic insulators at finite temperatures

    NASA Astrophysics Data System (ADS)

    Wang, Xi-guang; Chotorlishvili, L.; Guo, Guang-hua; Berakdar, J.

    2018-04-01

    Conversion of thermal energy into magnonic spin currents and/or effective electric polarization promises new device functionalities. A versatile approach is presented here for generating and controlling open circuit magnonic spin currents and an effective multiferroicity at a uniform temperature with the aid of spatially inhomogeneous, external, static electric fields. This field applied to a ferromagnetic insulator with a Dzyaloshinskii-Moriya type coupling changes locally the magnon dispersion and modifies the density of thermally excited magnons in a region of the scale of the field inhomogeneity. The resulting gradient in the magnon density can be viewed as a gradient in the effective magnon temperature. This effective thermal gradient together with local magnon dispersion result in an open-circuit, electric field controlled magnonic spin current. In fact, for a moderate variation in the external electric field the predicted magnonic spin current is on the scale of the spin (Seebeck) current generated by a comparable external temperature gradient. Analytical methods supported by full-fledge numerics confirm that both, a finite temperature and an inhomogeneous electric field are necessary for this emergent non-equilibrium phenomena. The proposal can be integrated in magnonic and multiferroic circuits, for instance to convert heat into electrically controlled pure spin current using for example nanopatterning, without the need to generate large thermal gradients on the nanoscale.

  14. Controlling hollow relativistic electron beam orbits with an inductive current divider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swanekamp, S. B.; Richardson, A. S.; Angus, J. R.

    2015-02-15

    A passive method for controlling the trajectory of an intense, hollow electron beam is proposed using a vacuum structure that inductively splits the beam's return current. A central post carries a portion of the return current (I{sub 1}), while the outer conductor carries the remainder (I{sub 2}). An envelope equation appropriate for a hollow electron beam is derived and applied to the current divider. The force on the beam trajectory is shown to be proportional to (I{sub 2}-I{sub 1}), while the average force on the envelope (the beam width) is proportional to the beam current I{sub b} = (I{sub 2} + I{sub 1}). Themore » values of I{sub 1} and I{sub 2} depend on the inductances in the return-current path geometries. Proper choice of the return-current geometries determines these inductances and offers control over the beam trajectory. Solutions using realistic beam parameters show that, for appropriate choices of the return-current-path geometry, the inductive current divider can produce a beam that is both pinched and straightened so that it approaches a target at near-normal incidence with a beam diameter that is on the order of a few mm.« less

  15. Reserve-building activities in multiple sclerosis patients and healthy controls: a descriptive study.

    PubMed

    Schwartz, Carolyn E; Ayandeh, Armon; Ramanathan, Murali; Benedict, Ralph; Dwyer, Michael G; Weinstock-Guttman, Bianca; Zivadinov, Robert

    2015-08-12

    Cognitive reserve has been implicated as a possible protective factor in multiple sclerosis (MS) but to date no study has compared reserve-building activities across disease course or to healthy controls. This study aims to describe differences in reserve-building activities across the MS disease course and healthy controls. Secondary analysis of a cross-sectional cohort study that included 276 healthy controls, and subjects with clinically isolated syndrome (CIS; n = 67), relapsing-remitting MS (RRMS; n = 358) and secondary progressive MS (PMS; n = 109). Past reserve-building activities were operationalized as occupational attainment and education. Current activities comprised 6 strenuous and 6 non-strenuous activities, including 5 reserve-building activities and television-watching. Multivariate Analysis of Variance models examined group differences in past and current activities, after adjusting for covariates. There were group differences in past and current reserve-building activities. SPMS patients had lower past reserve-building activities than healthy controls. All forms of MS engaged in fewer strenuous current reserve-building pursuits than healthy controls. RRMS read less than healthy controls. SPMS engaged in fewer job-related non-strenuous activities. All MS groups watched more television than healthy controls. MS patients show significantly fewer past and present reserve-building activities. Although it is difficult to establish causality without future prospective studies, lifestyle-modifying interventions should prioritize expanding MS patients' repertoire of strenuous and non-strenuous activities.

  16. System and method for motor fault detection using stator current noise cancellation

    DOEpatents

    Zhou, Wei; Lu, Bin; Nowak, Michael P.; Dimino, Steven A.

    2010-12-07

    A system and method for detecting incipient mechanical motor faults by way of current noise cancellation is disclosed. The system includes a controller configured to detect indicia of incipient mechanical motor faults. The controller further includes a processor programmed to receive a baseline set of current data from an operating motor and define a noise component in the baseline set of current data. The processor is also programmed to acquire at least on additional set of real-time operating current data from the motor during operation, redefine the noise component present in each additional set of real-time operating current data, and remove the noise component from the operating current data in real-time to isolate any fault components present in the operating current data. The processor is then programmed to generate a fault index for the operating current data based on any isolated fault components.

  17. Design of neural network model-based controller in a fed-batch microbial electrolysis cell reactor for bio-hydrogen gas production

    NASA Astrophysics Data System (ADS)

    Azwar; Hussain, M. A.; Abdul-Wahab, A. K.; Zanil, M. F.; Mukhlishien

    2018-03-01

    One of major challenge in bio-hydrogen production process by using MEC process is nonlinear and highly complex system. This is mainly due to the presence of microbial interactions and highly complex phenomena in the system. Its complexity makes MEC system difficult to operate and control under optimal conditions. Thus, precise control is required for the MEC reactor, so that the amount of current required to produce hydrogen gas can be controlled according to the composition of the substrate in the reactor. In this work, two schemes for controlling the current and voltage of MEC were evaluated. The controllers evaluated are PID and Inverse neural network (NN) controller. The comparative study has been carried out under optimal condition for the production of bio-hydrogen gas wherein the controller output is based on the correlation of optimal current and voltage to the MEC. Various simulation tests involving multiple set-point changes and disturbances rejection have been evaluated and the performances of both controllers are discussed. The neural network-based controller results in fast response time and less overshoots while the offset effects are minimal. In conclusion, the Inverse neural network (NN)-based controllers provide better control performance for the MEC system compared to the PID controller.

  18. Formation and Control of Cyanobacterial Toxins

    EPA Science Inventory

    This presentation will cover the formation of harmful algal blooms and the control of their toxins. Data will be presented from current ORD projects on the treatment of cyanobacterial toxins through drinking water treatment facilities. The results will demonstrate that current c...

  19. Monitoring circuit accurately measures movement of solenoid valve

    NASA Technical Reports Server (NTRS)

    Gillett, J. D.

    1966-01-01

    Solenoid operated valve in a control system powered by direct current issued to accurately measure the valve travel. This system is currently in operation with a 28-vdc power system used for control of fluids in liquid rocket motor test facilities.

  20. Plasma equilibrium control during slow plasma current quench with avoidance of plasma-wall interaction in JT-60U

    NASA Astrophysics Data System (ADS)

    Yoshino, R.; Nakamura, Y.; Neyatani, Y.

    1997-08-01

    In JT-60U a vertical displacement event (VDE) is observed during slow plasma current quench (Ip quench) for a vertically elongated divertor plasma with a single null. The VDE is generated by an error in the feedback control of the vertical position of the plasma current centre (ZJ). It has been perfectly avoided by improving the accuracy of the ZJ measurement in real time. Furthermore, plasma-wall interaction has been avoided successfully during slow Ip quench owing to the good performance of the plasma equilibrium control system

Top