Sample records for lung function fev1

  1. Donor predicted post-operative forced expiratory volume in one second predicts recipients' best forced expiratory volume in one second following size-reduced lung transplantation.

    PubMed

    Inci, Ilhan; Irani, Sarosh; Kestenholz, Peter; Benden, Christian; Boehler, Annette; Weder, Walter

    2011-01-01

    The limited number of available grafts is one of the major obstacles of lung transplantation. Size-reduced lung transplantation allows the use of oversized grafts for small recipients. Optimal lung size matching is vital to achieve best functional outcome and avoid potential problems when using oversized grafts. We hypothesise that donor-predicted postoperative forced expiratory volume in 1s (ppoFEV1) correlates with the recipient best FEV1 after size-reduced lung transplant, being useful for the estimation of function outcome. All patients undergoing size-reduced or standard bilateral lung transplantation were included (1992-2007). Donor ppoFEV1 was calculated and corrected with respect to size reduction and correlated with recipient measured best FEV1 post-transplant. In addition, pre- and postoperative clinical data including surgical complications and outcome of all size-reduced lung transplant recipients were compared with standard lung transplant recipients. A total of 61 size-reduced lung transplant recipients (lobar transplants, n=20; anatomic or non-anatomic resection, n=41) were included and compared to 145 standard transplants. The mean donor-recipient height difference was statistically significant between the two groups (p=0.0001). The mean donor ppoFEV1 was comparable with recipient best FEV1 (2.7±0.6 vs 2.6±0.7 l). There was a statistically significant correlation between donor ppoFEV1 and recipient best FEV1 (p=0.01, r=0.688). The 30-day mortality rate and 3-month, 1- and 5-year survival rates were comparable between the two groups. In size-reduced lung transplantation, postoperative recipient best FEV1 could be predicted from donor-calculated and corrected FEV1 with respect to its size reduction. Compared to standard lung transplantation, equivalent morbidity, mortality and functional results could be obtained after size-reduced lung transplantation. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  2. Post-9/11/2001 lung function trajectories by sex and race in World Trade Center-exposed New York City emergency medical service workers.

    PubMed

    Vossbrinck, Madeline; Zeig-Owens, Rachel; Hall, Charles B; Schwartz, Theresa; Moir, William; Webber, Mayris P; Cohen, Hillel W; Nolan, Anna; Weiden, Michael D; Christodoulou, Vasilios; Kelly, Kerry J; Aldrich, Thomas K; Prezant, David J

    2017-03-01

    To determine whether lung function trajectories after 9/11/2001 (9/11) differed by sex or race/ethnicity in World Trade Center-exposed Fire Department of the City of New York emergency medical service (EMS) workers. Serial cross-sectional study of pulmonary function tests (PFTs) taken between 9/11 and 9/10/2015. We used data from routine PFTs (forced expiratory volume in 1 s (FEV 1 ) and FEV 1 % predicted), conducted at 12-18 month intervals. FEV 1 and FEV 1 % predicted were assessed over time, stratified by sex, and race/ethnicity. We also assessed FEV 1 and FEV 1 % predicted in current, former and never-smokers. Among 1817 EMS workers, 334 (18.4%) were women, 979 (53.9%) self-identified as white and 939 (51.6%) were never-smokers. The median follow-up was 13.1 years (IQR 10.5-13.6), and the median number of PFTs per person was 11 (IQR 7-13). After large declines associated with 9/11, there was no discernible recovery in lung function. In analyses limited to never-smokers, the trajectory of decline in adjusted FEV 1 and FEV 1 % predicted was relatively parallel for men and women in the 3 racial/ethnic groups. Similarly, small differences in FEV 1 annual decline between groups were not clinically meaningful. Analyses including ever-smokers were essentially the same. 14 years after 9/11, most EMS workers continued to demonstrate a lack of lung function recovery. The trajectories of lung function decline, however, were parallel by sex and by race/ethnicity. These findings support the use of routine, serial measures of lung function over time in first responders and demonstrate no sex or racial sensitivity to exposure-related lung function decline. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Effects of Body Mass Index on Lung Function Index of Chinese Population

    NASA Astrophysics Data System (ADS)

    Guo, Qiao; Ye, Jun; Yang, Jian; Zhu, Changan; Sheng, Lei; Zhang, Yongliang

    2018-01-01

    To study the effect of body mass index (BMI) on lung function indexes in Chinese population. A cross-sectional study was performed on 10, 592 participants. The linear relationship between lung function and BMI was evaluated by multivariate linear regression analysis, and the correlation between BMI and lung function was assessed by Pearson correlation analysis. Correlation analysis showed that BMI was positively related with the decreasing of forced vital capacity (FVC), forced expiratory volume in one second (FEV1) and FEV1/FVC (P <0.05), the increasing of FVC% predicted value (FVC%pre) and FEV1% predicted value (FEV1%pre). These suggested that Chinese people can restrain the decline of lung function to prevent the occurrence and development of COPD by the control of BMI.

  4. Variation in lung function is associated with worse clinical outcomes in cystic fibrosis

    PubMed Central

    Heinzmann-Filho, João Paulo; Pinto, Leonardo Araujo; Marostica, Paulo José Cauduro; Donadio, Márcio Vinícius Fagundes

    2015-01-01

    ABSTRACT OBJECTIVE: To determine whether the variation in lung function over one year is associated with worse clinical outcomes, as well as with a decline in lung function in the following years, in patients with cystic fibrosis (CF). METHODS: This was a retrospective study involving CF patients (4-19 years of age), evaluated over a three-year period. We evaluated demographic characteristics, chronic Pseudomonas aeruginosa infection, antibiotic use, hospitalization, six-minute walk distance (6MWD), and lung function. The inclusion criterion was having undergone pulmonary function testing at least three times in the first year and at least once in each of the next two years. RESULTS: We evaluated 35 CF patients. The variation in FEV1 in the first year (ΔFEV1) was greater among those who, in the third year, showed reduced FEV1, had a below-average 6MWD, or were hospitalized than among those with normal FEV1, normal 6MWD, or no hospital admissions, in that same year (p < 0.05), although no such difference was found for antibiotic use in the third year. Subjects showing a ΔFEV1 ≥ 10% also showed a greater decline in FEV1 over the two subsequent years (p = 0.04). The ΔFEV1 also showed an inverse correlation with absolute FEV1 in the third year (r = −0.340, p = 0.04) and with the rate of FEV1 decline (r = −0.52, p = 0.001). Linear regression identified ΔFEV1 as a predictor of FEV1 decline (coefficient of determination, 0.27). CONCLUSIONS: Significant variation in lung function over one year seems to be associated with a higher subsequent rate of FEV1 decline and worse clinical outcomes in CF patients. Short-term ΔFEV1 might prove useful as a predictor of CF progression in clinical practice. PMID:26785959

  5. 3D ECG- and respiratory-gated non-contrast-enhanced (CE) perfusion MRI for postoperative lung function prediction in non-small-cell lung cancer patients: A comparison with thin-section quantitative computed tomography, dynamic CE-perfusion MRI, and perfusion scan.

    PubMed

    Ohno, Yoshiharu; Seki, Shinichiro; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Takenaka, Daisuke; Kassai, Yoshimori; Yui, Masao; Sugimura, Kazuro

    2015-08-01

    To compare predictive capabilities of non-contrast-enhanced (CE)- and dynamic CE-perfusion MRIs, thin-section multidetector computed tomography (CT) (MDCT), and perfusion scan for postoperative lung function in non-small cell lung cancer (NSCLC) patients. Sixty consecutive pathologically diagnosed NSCLC patients were included and prospectively underwent thin-section MDCT, non-CE-, and dynamic CE-perfusion MRIs and perfusion scan, and had their pre- and postoperative forced expiratory volume in one second (FEV1 ) measured. Postoperative percent FEV1 (po%FEV1 ) was then predicted from the fractional lung volume determined on semiquantitatively assessed non-CE- and dynamic CE-perfusion MRIs, from the functional lung volumes determined on quantitative CT, from the number of segments observed on qualitative CT, and from uptakes detected on perfusion scans within total and resected lungs. Predicted po%FEV1 s were then correlated with actual po%FEV1 s, which were %FEV1 s measured postoperatively. The limits of agreement were also determined. All predicted po%FEV1 s showed significant correlation (0.73 ≤ r ≤ 0.93, P < 0.0001) and limits of agreement with actual po%FEV1 (non-CE-perfusion MRI: 0.3 ± 10.0%, dynamic CE-perfusion MRI: 1.0 ± 10.8%, perfusion scan: 2.2 ± 14.1%, quantitative CT: 1.2 ± 9.0%, qualitative CT: 1.5 ± 10.2%). Non-CE-perfusion MRI may be able to predict postoperative lung function more accurately than qualitatively assessed MDCT and perfusion scan. © 2014 Wiley Periodicals, Inc.

  6. State-of-the-art radiological techniques improve the assessment of postoperative lung function in patients with non-small cell lung cancer.

    PubMed

    Ohno, Yoshiharu; Koyama, Hisanobu; Nogami, Munenobu; Takenaka, Daisuke; Onishi, Yumiko; Matsumoto, Keiko; Matsumoto, Sumiaki; Maniwa, Yoshimasa; Yoshimura, Masahiro; Nishimura, Yoshihiro; Sugimura, Kazuro

    2011-01-01

    The purpose of this study was to compare predictive capabilities for postoperative lung function in non-small cell lung cancer (NSCLC) patients of the state-of-the-art radiological methods including perfusion MRI, quantitative CT and SPECT/CT with that of anatomical method (i.e. qualitative CT) and traditional nuclear medicine methods such as planar imaging and SPECT. Perfusion MRI, CT, nuclear medicine study and measurements of %FEV(1) before and after lung resection were performed for 229 NSCLC patients (125 men and 104 women). For perfusion MRI, postoperative %FEV(1) (po%FEV(1)) was predicted from semi-quantitatively assessed blood volumes within total and resected lungs, for quantitative CT, it was predicted from the functional lung volumes within total and resected lungs, for qualitative CT, from the number of segments of total and resected lungs, and for nuclear medicine studies, from uptakes within total and resected lungs. All SPECTs were automatically co-registered with CTs for preparation of SPECT/CTs. Predicted po%FEV(1)s were then correlated with actual po%FEV(1)s, which were measured %FEV(1)s after operation. The limits of agreement were also evaluated. All predicted po%FEV(1)s showed good correlation with actual po%FEV(1)s (0.83≤r≤0.88, p<0.0001). Perfusion MRI, quantitative CT and SPECT/CT demonstrated better correlation than other methods. The limits of agreement of perfusion MRI (4.4±14.2%), quantitative CT (4.7±14.2%) and SPECT/CT (5.1±14.7%) were less than those of qualitative CT (6.0±17.4%), planar imaging (5.8±18.2%), and SPECT (5.5±16.8%). State-of-the-art radiological methods can predict postoperative lung function in NSCLC patients more accurately than traditional methods. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  7. Prediction of post-operative pulmonary function after lobectomy for primary lung cancer: A comparison among counting method, effective lobar volume, and lobar collapsibility using inspiratory/expiratory CT.

    PubMed

    Yabuuchi, Hidetake; Kawanami, Satoshi; Kamitani, Takeshi; Yonezawa, Masato; Yamasaki, Yuzo; Yamanouchi, Torahiko; Nagao, Michinobu; Okamoto, Tatsuro; Honda, Hiroshi

    2016-11-01

    To compare the predictabilities of postoperative pulmonary function after lobectomy for primary lung cancer among counting method, effective lobar volume, and lobar collapsibility. Forty-nine patients who underwent lobectomy for primary lung cancer were enrolled. All patients underwent inspiratory/expiratory CT and pulmonary function tests 2 weeks before surgery and postoperative pulmonary function tests 6-7 months after surgery. Pulmonary function losses (ΔFEV 1.0 and ΔVC) were calculated from the pulmonary function tests. Predictive postoperative pulmonary function losses (ppoΔFEV 1.0 and ppoΔVC) were calculated using counting method, effective volume, and lobar collapsibility. Correlations and agreements between ΔFEV 1.0 and ppoFEV 1.0 and those between ΔVC and ppoΔVC were tested among three methods using Spearman's correlation coefficient and Bland-Altman plots. ΔFEV 1.0 and ppoΔFEV 1.0insp-exp were strongly correlated (r=0.72), whereas ΔFEV 1.0 and ppoΔFEV 1.0count and ΔFEV 1.0 and Pred. ΔFEV 1.0eff.vol. were moderately correlated (r=0.50, 0.56). ΔVC and ppoΔVC eff.vol. (r=0.71) were strongly correlated, whereas ΔVC and ppoΔVC count , and ΔVC and ppoΔVC insp-exp were moderately correlated (r=0.55, 0.42). Volumetry from inspiratory/expiratory CT data could be useful to predict postoperative pulmonary function after lobectomy for primary lung cancer. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Influence of Pulmonary Rehabilitation on Lung Function Changes After the Lung Resection for Primary Lung Cancer in Patients with Chronic Obstructive Pulmonary Disease.

    PubMed

    Mujovic, Natasa; Mujovic, Nebojsa; Subotic, Dragan; Ercegovac, Maja; Milovanovic, Andjela; Nikcevic, Ljubica; Zugic, Vladimir; Nikolic, Dejan

    2015-11-01

    Influence of physiotherapy on the outcome of the lung resection is still controversial. Study aim was to assess the influence of physiotherapy program on postoperative lung function and effort tolerance in lung cancer patients with chronic obstructive pulmonary disease (COPD) that are undergoing lobectomy or pneumonectomy. The prospective study included 56 COPD patients who underwent lung resection for primary non small-cell lung cancer after previous physiotherapy (Group A) and 47 COPD patients (Group B) without physiotherapy before lung cancer surgery. In Group A, lung function and effort tolerance on admission were compared with the same parameters after preoperative physiotherapy. Both groups were compared in relation to lung function, effort tolerance and symptoms change after resection. In patients with tumors requiring a lobectomy, after preoperative physiotherapy, a highly significant increase in FEV1, VC, FEF50 and FEF25 of 20%, 17%, 18% and 16% respectively was registered with respect to baseline values. After physiotherapy, a significant improvement in 6-minute walking distance was achieved. After lung resection, the significant loss of FEV1 and VC occurred, together with significant worsening of the small airways function, effort tolerance and symptomatic status. After the surgery, a clear tendency existed towards smaller FEV1 loss in patients with moderate to severe, when compared to patients with mild baseline lung function impairment. A better FEV1 improvement was associated with more significant loss in FEV1. Physiotherapy represents an important part of preoperative and postoperative treatment in COPD patients undergoing a lung resection for primary lung cancer.

  9. Overweight, Obesity, and Lung Function in Children and Adults-A Meta-analysis.

    PubMed

    Forno, Erick; Han, Yueh-Ying; Mullen, James; Celedón, Juan C

    There is conflicting evidence on the effect of obesity on lung function in adults and children with and without asthma. We aimed to evaluate the relation between overweight or obesity and lung function, and whether such relationship varies by age, sex, or asthma status. We searched PubMed, Scopus, CINAHL, Cochrane, and EMBASE for all studies (in English) reporting on obesity status (by body mass index) and lung function, from 2005 to 2017. Main outcomes were forced expiratory volume in 1 second (FEV 1 ), forced vital capacity (FVC), FEV 1 /FVC, forced expiratory flow between 25th and 75th percentile of the forced vital capacity (FEF 25-75 ), total lung capacity (TLC), residual volume (RV), and functional residual capacity (FRC). Random-effects models were used to calculate the pooled risk estimates; each study was weighed by the inverse effect size variance. For each outcome, we compared overweight or obese ("obese") subjects with those of normal weight. All measures of lung function were decreased among obese subjects. Obese adults showed a pattern (lower FEV 1 , FVC, TLC, and RV) different from obese children (more pronounced FEV 1 /FVC deficit with unchanged FEV 1 or FVC). There were also seemingly different patterns by asthma status, in that subjects without asthma had more marked decreases in FEV 1 , TLC, RV, and FRC than subjects with asthma. Subjects who were obese (as compared with overweight) had even further decreased FEV 1 , FVC, TLC, RV, and FRC. Obesity is detrimental to lung function, but specific patterns differ between children and adults. Physicians should be aware of adverse effects of obesity on lung function, and weight control should be considered in the management of airway disease among the obese. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  10. Reduction of Pulmonary Function After Surgical Lung Resections of Different Volume

    PubMed Central

    Cukic, Vesna

    2014-01-01

    Introduction: In recent years an increasing number of lung resections are being done because of the rising prevalence of lung cancer that occurs mainly in patients with limited lung function, what is caused with common etiologic factor - smoking cigarettes. Objective: To determine how big the loss of lung function is after surgical resection of lung of different range. Methods: The study was done on 58 patients operated at the Clinic for thoracic surgery KCU Sarajevo, previously treated at the Clinic for pulmonary diseases “Podhrastovi” in the period from 01.06.2012. to 01.06.2014. The following resections were done: pulmectomy (left, right), lobectomy (upper, lower: left and right). The values of postoperative pulmonary function were compared with preoperative ones. As a parameter of lung function we used FEV1 (forced expiratory volume in one second), and changes in FEV1 are expressed in liters and in percentage of the recorded preoperative and normal values of FEV1. Measurements of lung function were performed seven days before and 2 months after surgery. Results: Postoperative FEV1 was decreased compared to preoperative values. After pulmectomy the maximum reduction of FEV1 was 44%, and after lobectomy it was 22% of the preoperative values. Conclusion: Patients with airway obstruction are limited in their daily life before the surgery, and an additional loss of lung tissue after resection contributes to their inability. Potential benefits of lung resection surgery should be balanced in relation to postoperative morbidity and mortality. PMID:25568542

  11. A new approach to assess COPD by identifying lung function break-points

    PubMed Central

    Eriksson, Göran; Jarenbäck, Linnea; Peterson, Stefan; Ankerst, Jaro; Bjermer, Leif; Tufvesson, Ellen

    2015-01-01

    Purpose COPD is a progressive disease, which can take different routes, leading to great heterogeneity. The aim of the post-hoc analysis reported here was to perform continuous analyses of advanced lung function measurements, using linear and nonlinear regressions. Patients and methods Fifty-one COPD patients with mild to very severe disease (Global Initiative for Chronic Obstructive Lung Disease [GOLD] Stages I–IV) and 41 healthy smokers were investigated post-bronchodilation by flow-volume spirometry, body plethysmography, diffusion capacity testing, and impulse oscillometry. The relationship between COPD severity, based on forced expiratory volume in 1 second (FEV1), and different lung function parameters was analyzed by flexible nonparametric method, linear regression, and segmented linear regression with break-points. Results Most lung function parameters were nonlinear in relation to spirometric severity. Parameters related to volume (residual volume, functional residual capacity, total lung capacity, diffusion capacity [diffusion capacity of the lung for carbon monoxide], diffusion capacity of the lung for carbon monoxide/alveolar volume) and reactance (reactance area and reactance at 5Hz) were segmented with break-points at 60%–70% of FEV1. FEV1/forced vital capacity (FVC) and resonance frequency had break-points around 80% of FEV1, while many resistance parameters had break-points below 40%. The slopes in percent predicted differed; resistance at 5 Hz minus resistance at 20 Hz had a linear slope change of −5.3 per unit FEV1, while residual volume had no slope change above and −3.3 change per unit FEV1 below its break-point of 61%. Conclusion Continuous analyses of different lung function parameters over the spirometric COPD severity range gave valuable information additional to categorical analyses. Parameters related to volume, diffusion capacity, and reactance showed break-points around 65% of FEV1, indicating that air trapping starts to dominate in moderate COPD (FEV1 =50%–80%). This may have an impact on the patient’s management plan and selection of patients and/or outcomes in clinical research. PMID:26508849

  12. Clinical value of CT-based preoperative software assisted lung lobe volumetry for predicting postoperative pulmonary function after lung surgery

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Beyer, Florian; Hoffknecht, Petra; Dicken, Volker; Kuhnigk, Jan-Martin; Lange, Tobias; Thomas, Michael; Heindel, Walter

    2005-04-01

    This study was aimed to evaluate a morphology-based approach for prediction of postoperative forced expiratory volume in one second (FEV1) after lung resection from preoperative CT scans. Fifteen Patients with surgically treated (lobectomy or pneumonectomy) bronchogenic carcinoma were enrolled in the study. A preoperative chest CT and pulmonary function tests before and after surgery were performed. CT scans were analyzed by prototype software: automated segmentation and volumetry of lung lobes was performed with minimal user interaction. Determined volumes of different lung lobes were used to predict postoperative FEV1 as percentage of the preoperative values. Predicted FEV1 values were compared to the observed postoperative values as standard of reference. Patients underwent lobectomy in twelve cases (6 upper lobes; 1 middle lobe; 5 lower lobes; 6 right side; 6 left side) and pneumonectomy in three cases. Automated calculation of predicted postoperative lung function was successful in all cases. Predicted FEV1 ranged from 54% to 95% (mean 75% +/- 11%) of the preoperative values. Two cases with obviously erroneous LFT were excluded from analysis. Mean error of predicted FEV1 was 20 +/- 160 ml, indicating absence of systematic error; mean absolute error was 7.4 +/- 3.3% respective 137 +/- 77 ml/s. The 200 ml reproducibility criterion for FEV1 was met in 11 of 13 cases (85%). In conclusion, software-assisted prediction of postoperative lung function yielded a clinically acceptable agreement with the observed postoperative values. This method might add useful information for evaluation of functional operability of patients with lung cancer.

  13. Gender Differences in the Association of Individual and Contextual Exposures with Lung Function in a Rural Canadian Population.

    PubMed

    Janzen, Bonnie; Karunanayake, Chandima; Rennie, Donna; Pickett, William; Lawson, Joshua; Kirychuk, Shelley; Hagel, Louise; Senthilselvan, Ambikaipakan; Koehncke, Niels; Dosman, James; Pahwa, Punam

    2017-02-01

    To investigate the association of individual and contextual exposures with lung function by gender in rural-dwelling Canadians. A cross-sectional mail survey obtained completed questionnaires on exposures from 8263 individuals; a sub-sample of 1609 individuals (762 men, 847 women) additionally participated in clinical lung function testing. The three dependent variables were forced expired volume in one second (FEV 1 ), forced vital capacity (FVC), and FEV 1 /FVC ratio. Independent variables included smoking, waist circumference, body mass index, indoor household exposures (secondhand smoke, dampness, mold, musty odor), occupational exposures (grain dust, pesticides, livestock, farm residence), and socioeconomic status. The primary analysis was multiple linear regression, conducted separately for each outcome. The potential modifying influence of gender was tested in multivariable models using product terms between gender and each independent variable. High-risk waist circumference was related to reduced FVC and FEV 1 for both genders, but the effect was more pronounced in men. Greater pack-years smoking was associated with lower lung function values. Exposure to household smoke was related to reduced FEV 1 , and exposure to livestock, with increased FEV 1 . Lower income adequacy was associated with reduced FVC and FEV 1 . High-risk waist circumference was more strongly associated with reduced lung function in men than women. Longitudinal research combined with rigorous exposure assessment is needed to clarify how sex and gender interact to impact lung function in rural populations.

  14. A prospective cohort study among new Chinese coal miners: the early pattern of lung function change.

    PubMed

    Wang, M-L; Wu, Z-E; Du, Q-G; Petsonk, E L; Peng, K-L; Li, Y-D; Li, S-K; Han, G-H; Atffield, M D

    2005-11-01

    To investigate the early pattern of longitudinal change in forced expiratory volume in 1 second (FEV1) among new Chinese coal miners, and the relation between coal mine dust exposure and the decline of lung function. The early pattern of lung function changes in 317 newly hired Chinese underground coal miners was compared to 132 referents. This three year prospective cohort study involved a pre-employment and 15 follow up health surveys, including a questionnaire and spirometry tests. Twice a month, total and respirable dust area sampling was done. The authors used a two stage analysis and a linear mixed effects model approach to analyse the longitudinal spirometry data, and to investigate the changes in FEV1 over time, controlling for age, height, pack years of smoking, mean respirable dust concentration, the room temperature during testing, and the groupxtime interaction terms. FEV1 change over time in new miners is non-linear. New miners experience initial rapid FEV1 declines, primarily during the first year of mining, little change during the second year, and partial recovery during the third year. Both linear and quadratic time trends in FEV1 change are highly significant. Smoking miners lost more FEV1 than non-smokers. Referents, all age less than 20 years, showed continued lung growth, whereas the miners who were under age 20 exhibited a decline in FEV1. Dust and smoking affect lung function in young, newly hired Chinese coal miners. FEV1 change over the first three years of employment is non-linear. The findings have implications for both methods and interpretation of medical screening in coal mining and other dusty work: during the first several years of employment more frequent testing may be desirable, and caution is required in interpreting early FEV1 declines.

  15. Lung function status of some Nigerian men and women chronically exposed to fish drying using burning firewood.

    PubMed

    Peters, E J; Esin, R A; Immananagha, K K; Siziya, S; Osim, E E

    1999-05-01

    To determine the lung function status of some Nigerian men and women chronically exposed to fish drying using burning firewood. Case control study. Ibaka, Utaewa and Ikanga fishing settlements. 183 males and 192 females engaged in fishing, aged 20 to 45 years who have been exposed for a minimum of five years as cases. The control group comprised sex matched male (142) and female (152) Nigerians from the same area who were not exposed to any known air pollutant. Lung function indices: FVC, FEV1, FEV1% and PEFR. Lung function indices were significantly lower in men engaged in fishing than in their controls: FVC [mean (SD): 2.98 (0.20) vs 3.52 (0.29), p < 0.001]; FEV1 [2.08 (0.18) vs 2.82 (0.25), p < 0.001]; FEV1% [69.8 (3.1) vs 80.2 (6.7), p < 0.001]; and PEFR [335 (22) vs 592 (99), p < 0.001], respectively. Similarly, lung function indices were lower in females in the fishing industry than in their controls; FVC [2.42 (0.17) vs 3.02 (0.24), p < 0.001]; FEV1 [1.70 (0.19) vs 2.55 (0.21), p < 0.001]; FEV1% [72.9 (3.2) vs 84.4 (6.7), p < 0.001]; and PEFR [298 (22) vs 418 (34), p < 0.001]. All the lung function indices (except FEV1%) of the fishermen and women declined significantly (p < 0.001) with their duration of exposure. The results showed a predominantly mixed pattern (restrictive and obstructive) of respiratory defect. There were higher prevalences of respiratory and other symptoms among the cases than the controls. The respiratory symptoms included cough with sputum, chest pain, dyspnoea catarrh and sneezing and unproductive cough. Other symptoms were eye and skin irritation, internal heat and headache. Chronic exposure to fish drying using burning firewood can impair lung function and cause respiratory and other symptoms.

  16. Lung function decline in bronchial asthma.

    PubMed

    Cibella, Fabio; Cuttitta, Giuseppina; Bellia, Vincenzo; Bucchieri, Salvatore; D'Anna, Silvestre; Guerrera, Daniela; Bonsignore, Giovanni

    2002-12-01

    We evaluated the longitudinal changes in lung function and the factors associated with FEV(1) changes over time in a sample of asthmatic subjects. FEV(1) measures were recorded every 3 months over a 5-year follow-up period. To compare all subjects independently of body size, FEV(1) values were normalized for the subject's height at the third power. We evaluated the possible effect of age, baseline FEV(1), disease duration, and FEV(1) variability on the rate of change of FEV(1). We studied 142 subjects with asthma diagnosed on the basis of validated clinical and functional criteria. FEV(1) showed a linear decay with aging in each subject. For a subject 1.65 m in height, the median overall FEV(1) decay was 40.9 mL/yr. FEV(1) decay slopes were significantly influenced by age and sex, being steeper in younger male subjects. A significant interaction was found between age and baseline FEV(1): the FEV(1) decay was significantly higher among younger asthmatics with a poorer baseline functional condition. A longer disease duration was associated with a lower FEV(1) slope. FEV(1) variability was strongly associated with an increased rate of FEV(1) decline. FEV(1) decline in patients with bronchial asthma is significantly influenced by baseline FEV(1), disease duration, and FEV(1) variability. Moreover, the rate of FEV(1) decline seems to increase in younger subjects only when the baseline function is poorer.

  17. Prevalence and determinants of airflow limitation in urban and rural children exposed to cooking fuels in South-East Nigeria.

    PubMed

    Oguonu, Tagbo; Obumneme-Anyim, Ijeoma N; Eze, Joy N; Ayuk, Adaeze C; Okoli, Chinyere V; Ndu, Ikenna K

    2018-05-01

    Background Biofuels and other cooking fuels are used in households in low- and middle-income countries. Aim To investigate the impact of cooking fuels on lung function in children in urban and rural households in South-East Nigeria. Methods The multi-stage sampling method was used to enroll children exposed to cooking fuel in the communities. Lung function values FEV1, FVC and the FEV1/FVC ratio, were measured with ndd EasyOne R spirometer. Airflow limitation was determined with FEV1/FVC Z-score values at -1.64 as the lower limit of normal (LLN5). The Global Lung Function Initiative 2012 software was used to calculate the lung function indices. Results The median age (range) of the 912 children enrolled was 10.6 years (6-18). Altogether, 468 (51.6%) children lived in rural areas. Seven hundred and thirty-seven (80.7%) were directly exposed to cooking fuels (418/737, 56.5% in rural areas). Wood and kerosene were the dominant fuels in rural and urban households. The respective mean Z-scores of the exposed children in rural and urban were zFEV1 -0.62, FVC -0.21, FEV1/FVC -0.83 and zFEV1 -0.57, zFVC -0.14, FEV1/FVC -0.75. Few (5.2%, 38/737) of the children had airflow limitation. Most of them (60.5%, 25/38) lived in the rural community; the lowest FEV1/FVC Z-scores were those of exposed to a combination of fuels. Conclusion Exposure to cooking fuels affects lung function in children with airway limitation in a small proportion, Control measures are advocated to reduce the morbidity related to cooking fuels exposure.

  18. Metal dust exposure and lung function deterioration among steel workers: an exposure-response relationship.

    PubMed

    Hamzah, Nurul Ainun; Mohd Tamrin, Shamsul Bahri; Ismail, Noor Hassim

    2016-07-01

    Metallic dust is a heterogeneous substance with respiratory sensitizing properties. Its long term exposure adversely affected lung function, thus may cause acute or chronic respiratory diseases. A cross-sectional study was conducted in a steel factory in Terengganu, Malaysia to assess the metal dust exposure and its relationship to lung function values among 184 workers. Metal dust concentrations values (Co, Cr, and Ni) for each worker were collected using air personal sampling. Lung function values (FEV 1 , FVC, and %FEV 1 /FVC) were determined using spirometer. Exposure to cobalt and chromium were 1-3 times higher than permissible exposure limit (PEL) while nickel was not exceeding the PEL. Cumulative of chromium was the predictor to all lung function values (FEV 1 , FVC, and %FEV 1 /FVC). Frequency of using mask was positively associated with FVC (Adj b = 0.263, P = 0.011) while past respiratory illnesses were negatively associated with %FEV 1 /FVC (Adj b = -1.452, P = 0.026). Only few workers (36.4%) were found to wear their masks all times during the working hours. There was an exposure-response relationship of cumulative metal dust exposure with the deterioration of lung function values. Improvement of control measures as well as proper and efficient use or personal protection equipment while at work could help to protect the respiratory health of workers.

  19. Bronchoscopic Lung Volume Reduction with Endobronchial Valves in Low-FEV1 Patients.

    PubMed

    Darwiche, Kaid; Karpf-Wissel, Rüdiger; Eisenmann, Stephan; Aigner, Clemens; Welter, Stefan; Zarogoulidis, Paul; Hohenforst-Schmidt, Wolfgang; Freitag, Lutz; Oezkan, Filiz

    2016-01-01

    Bronchoscopic lung volume reduction (BLVR) with valves has been shown to improve lung function, exercise capacity, and quality of life in patients with emphysema, but only few patients with forced expiratory volume in 1 s (FEV1) ≤20% predicted have been included in former studies. Although the procedure can be performed safely, pneumothorax is a frequent complication, which can be critical for these very severely diseased patients. The aim of the study was to assess the safety of BLVR in patients with a very advanced stage of emphysema, as indicated by FEV1 ≤20% predicted. Patients in whom BLVR was performed between January 2013 and August 2015 were included in this analysis if their baseline predicted FEV1 was ≤20%. BLVR, performed only if collateral ventilation was absent, achieved complete occlusion of the target lobe. All patients were closely monitored and were not discharged before the fourth day after BLVR. Twenty patients with FEV1 ≤20% predicted were included in the analysis. Lung volume reduction was achieved in 65% of the cases. Pneumothorax occurred in 4 cases (20%). No patient died. Lung function and exercise tolerance improved after 1 and 3 months, respectively. BLVR with valves can be safely performed in patients with FEV1 ≤20% predicted when close postprocedural monitoring is provided. Improvement in lung function and exercise capacity can be achieved. © 2016 S. Karger AG, Basel.

  20. Clinical and Radiographic Predictors of GOLD–Unclassified Smokers in the COPDGene Study

    PubMed Central

    Hokanson, John E.; Murphy, James R.; Regan, Elizabeth A.; Make, Barry J.; Lynch, David A.; Crapo, James D.; Silverman, Edwin K.

    2011-01-01

    Rationale: A significant proportion of smokers have lung function impairment characterized by a reduced FEV1 with a preserved FEV1/FVC ratio. These smokers are a poorly characterized group due to their systematic exclusion from chronic obstructive pulmonary disease (COPD) studies. Objectives: To characterize the clinical, functional, and radiographic features of Global Initiative for Chronic Obstructive Lung Disease (GOLD)-Unclassified (FEV1/FVC ≥ 0.7 and FEV1 < 80% predicted) and lower limits of normal (LLN)-unclassified (FEV1/FVC ≥ LLN and FEV1 < LLN) subjects compared to smokers with normal lung function and subjects with COPD. Methods: Data from the first 2,500 subjects enrolled in the COPDGene study were analyzed. All subjects had 10 or more pack-years of smoking and were between the ages of 45 and 80 years. Multivariate regression models were constructed to determine the clinical and radiological variables associated with GOLD-Unclassified (GOLD-U) and LLN-Unclassified status. Separate multivariate regressions were performed in the subgroups of subjects with complete radiologic measurement variables available. Measurements and Main Results: GOLD-U smokers account for 9% of smokers in COPDGene and have increased body mass index (BMI), a disproportionately reduced total lung capacity, and a higher proportion of nonwhite subjects and subjects with diabetes. GOLD-U subjects exhibit increased airway wall thickness compared to smoking control subjects and decreased gas trapping and bronchodilator responsiveness compared to subjects with COPD. When LLN criteria were used to define the “unclassified” group, African American subjects were no longer overrepresented. Both GOLD-U and LLN-Unclassified subjects demonstrated a wide range of lung function impairment, BMI, and percentage of total lung emphysema. Conclusions: Subjects with reduced FEV1 and a preserved FEV1/FVC ratio are a heterogeneous group with significant symptoms and functional limitation who likely have a variety of underlying etiologies beyond increased BMI. Clinical trial registered with www.clinicaltrials.gov (NCT000608764). PMID:21493737

  1. Functional improvement in patients with idiopathic pulmonary fibrosis undergoing single lung transplantation *

    PubMed Central

    Rubin, Adalberto Sperb; Nascimento, Douglas Zaione; Sanchez, Letícia; Watte, Guilherme; Holand, Arthur Rodrigo Ronconi; Fassbind, Derrick Alexandre; Camargo, José Jesus

    2015-01-01

    Abstract Objective: To evaluate the changes in lung function in the first year after single lung transplantation in patients with idiopathic pulmonary fibrosis (IPF). Methods: We retrospectively evaluated patients with IPF who underwent single lung transplantation between January of 2006 and December of 2012, reviewing the changes in the lung function occurring during the first year after the procedure. Results: Of the 218 patients undergoing lung transplantation during the study period, 79 (36.2%) had IPF. Of those 79 patients, 24 (30%) died, and 11 (14%) did not undergo spirometry at the end of the first year. Of the 44 patients included in the study, 29 (66%) were men. The mean age of the patients was 57 years. Before transplantation, mean FVC, FEV1, and FEV1/FVC ratio were 1.78 L (50% of predicted), 1.48 L (52% of predicted), and 83%, respectively. In the first month after transplantation, there was a mean increase of 12% in FVC (400 mL) and FEV1 (350 mL). In the third month after transplantation, there were additional increases, of 5% (170 mL) in FVC and 1% (50 mL) in FEV1. At the end of the first year, the functional improvement persisted, with a mean gain of 19% (620 mL) in FVC and 16% (430 mL) in FEV1. Conclusions: Single lung transplantation in IPF patients who survive for at least one year provides significant and progressive benefits in lung function during the first year. This procedure is an important therapeutic alternative in the management of IPF. PMID:26398749

  2. Metal dust exposure and lung function deterioration among steel workers: an exposure-response relationship

    PubMed Central

    Hamzah, Nurul Ainun; Mohd Tamrin, Shamsul Bahri; Ismail, Noor Hassim

    2016-01-01

    Background Metallic dust is a heterogeneous substance with respiratory sensitizing properties. Its long term exposure adversely affected lung function, thus may cause acute or chronic respiratory diseases. Methods A cross-sectional study was conducted in a steel factory in Terengganu, Malaysia to assess the metal dust exposure and its relationship to lung function values among 184 workers. Metal dust concentrations values (Co, Cr, and Ni) for each worker were collected using air personal sampling. Lung function values (FEV1, FVC, and %FEV1/FVC) were determined using spirometer. Results Exposure to cobalt and chromium were 1–3 times higher than permissible exposure limit (PEL) while nickel was not exceeding the PEL. Cumulative of chromium was the predictor to all lung function values (FEV1, FVC, and %FEV1/FVC). Frequency of using mask was positively associated with FVC (Adj b = 0.263, P = 0.011) while past respiratory illnesses were negatively associated with %FEV1/FVC (Adj b = –1.452, P = 0.026). Only few workers (36.4%) were found to wear their masks all times during the working hours. Conclusions There was an exposure-response relationship of cumulative metal dust exposure with the deterioration of lung function values. Improvement of control measures as well as proper and efficient use or personal protection equipment while at work could help to protect the respiratory health of workers. PMID:27392157

  3. Rubberwood dust and lung function among Thai furniture factory workers.

    PubMed

    Thetkathuek, Anamai; Yingratanasuk, Tanongsak; Demers, Paul A; Thepaksorn, Phayong; Saowakhontha, Sastri; Keifer, Matthew C

    2010-01-01

    The objective of this study was to assess factors affecting lung function among 685 workers in the rubberwood (Hevea brasiliensis) furniture industry in the Chonburi and Rayung provinces of eastern Thailand. Study data were gathered using questionnaires, by sampling wood dust, and by spirometry. The mean wood dust exposure level in the factories was 4.08 mg/m3 (SD = 1.42, range: 1.15-11.17 mg/m3). The mean overall percent of predicted forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and FEV1/FVC values were 84 % (SD = 13.41), 86 % (SD = 14.40), and 99% (SD = 10.42), respectively. Significant negative correlations were found between mean dust exposure levels and FVC (p = 0.0008), and FEV1/FVC% (p < 0.001), but not FEV1 (p = 0.074). An association between decline in lung function and wood dust levels among wood workers suggests that rubberwood dust exposure negatively affects lung function.

  4. Drillers and mill operators in an open-pit gold mine are at risk for impaired lung function.

    PubMed

    Vinnikov, Denis

    2016-01-01

    Occupational studies of associations of exposures with impaired lung function in mining settings are built on exposure assessment and far less often on workplace approach, so the aim of this study was to identify vulnerable occupational groups for early lung function reduction in a cohort of healthy young miners. Data from annual screening lung function tests in gold mining company in Kyrgyzstan were linked to occupations. We compared per cent predicted forced expiratory volume in one second (FEV1), forced vital capacity (FVC) and FEV1/FVC between occupational groups and tested selected occupations in multivariate regression adjusted for smoking and work duration for the following outcomes: FEV1 < 80 %, FEV1/FVC < 70 % and both. 1550 tests of permanent workers of 41 occupations (mean age 40.5 ± 9.2 years, 29.8 % never smokers) were included in the analysis. The mean overall VC was 103.0 ± 12.9 %; FVC 109.1 ± 13.0 % and FEV1 100.2 ± 25.9 %. Drillers and smoking food handlers had the lowest FEV1%. In non-smokers, the lowest FEV1 was in drillers (94.9 ± 11.3 % compared to 115.2 ± 17.7 % in engineers). Drillers (adjusted odds ratio (OR) 1.53 (95 % confidence interval (CI) 1.11-2.09)) and mill operators (OR 2.01 (1.13-3.57)) were at greater risk of obstructive ventilation pattern (FEV1/FVC < 70 %). Drilling and mill operations are the highest risk jobs in an open-pit mine for reduced lung function. Occupational medical clinic at site should follow-up workers in these occupations with depth and strongly recommend smoking cessation.

  5. Obstructive lung disease as a complication in post pulmonary TB

    NASA Astrophysics Data System (ADS)

    Tarigan, A. P.; Pandia, P.; Eyanoer, P.; Tina, D.; Pratama, R.; Fresia, A.; Tamara; Silvanna

    2018-03-01

    The case of post TB is a problem that arises in the community. Pulmonary tuberculosis (TB) can affect lung function. Therefore, we evaluated impaired pulmonary function in subjects with diagnosed prior pulmonary TB. A Case Series study, pulmonary function test was performed in subjects with a history of pulmonary tuberculosis; aged ≥18 years were included. Exclusion criteria was a subject who had asthma, obesity, abnormal thorax and smoking history. We measured FEV1 and FVC to evaluate pulmonary function. Airflow obstruction was FEV1/FVC%<75 and restriction was FVC<80% according to Indonesia’s pneumomobile project. This study was obtained from 23 patients with post pulmonary TB, 5 subjects (23%) had airflow obstruction with FEV1/FVC% value <75%, 15 subjects (71.4%) had abnormalities restriction with FVC value <80% and 3 subjects (5.6%) had normal lung function. Obstructive lung disease is one of the complications of impaired lung function in post pulmonary TB.

  6. Lung function decline rates according to GOLD group in patients with chronic obstructive pulmonary disease

    PubMed Central

    Kim, Joohae; Yoon, Ho Il; Oh, Yeon-Mok; Lim, Seong Yong; Lee, Ji-Hyun; Kim, Tae-Hyung; Lee, Sang Yeub; Lee, Jin Hwa; Lee, Sang-Do; Lee, Chang-Hoon

    2015-01-01

    Background Since the Global Initiative for Chronic Obstructive Lung Disease (GOLD) groups A–D were introduced, the lung function changes according to group have been evaluated rarely. Objective We investigated the rate of decline in annual lung function in patients categorized according to the 2014 GOLD guidelines. Methods Patients with COPD included in the Korean Obstructive Lung Disease (KOLD) prospective study, who underwent yearly postbronchodilator spirometry at least three times, were included. The main outcome was the annual decline in postbronchodilator forced expiratory volume in 1 second (FEV1), which was analyzed by random-slope and random-intercept mixed linear regression. Results A total 175 participants were included. No significant postbronchodilator FEV1 decline was observed between the groups (−34.4±7.9 [group A]; −26.2±9.4 [group B]; −22.7±16.0 [group C]; and −24.0±8.7 mL/year [group D]) (P=0.79). The group with less symptoms (−32.3±7.2 vs −25.0±6.5 mL/year) (P=0.44) and the low risk group (−31.0±6.1 vs −23.6±7.7 mL/year) (P=0.44) at baseline showed a more rapid decline in the postbronchodilator FEV1, but the trends were not statistically significant. However, GOLD stages classified by FEV1 were significantly related to the annual lung function decline. Conclusion There was no significant difference in lung function decline rates according to the GOLD groups. Prior classification using postbronchodilator FEV1 predicts decline in lung function better than does the new classification. PMID:26379432

  7. Lung function and airway obstruction: associations with circulating markers of cardiac function and incident heart failure in older men—the British Regional Heart Study

    PubMed Central

    Wannamethee, S Goya; Shaper, A Gerald; Papacosta, Olia; Lennon, Lucy; Welsh, Paul; Whincup, Peter H

    2016-01-01

    Aims The association between lung function and cardiac markers and heart failure (HF) has been little studied in the general older population. We have examined the association between lung function and airway obstruction with cardiac markers N-terminal pro-brain natriuretic peptide (NT-proBNP) and cardiac troponin T (cTnT) and risk of incident HF in older men. Methods and results Prospective study of 3242 men aged 60–79 years without prevalent HF or myocardial infarction followed up for an average period of 13 years, in whom 211 incident HF cases occurred. Incident HF was examined in relation to % predicted FEV1 and FVC. The Global Initiative on Obstructive Lung Diseases spirometry criteria were used to define airway obstruction. Reduced FEV1, but not FVC in the normal range, was significantly associated with increased risk of HF after adjustment for established HF risk factors including inflammation. The adjusted HRs comparing men in the 6–24th percentile with the highest quartile were 1.91 (1.24 to 2.94) and 1.30 (0.86 to 1.96) for FEV1 and FVC, respectively. FEV1 and FVC were inversely associated with NT-proBNP and cTnT, although the association between FEV1 and incident HF remained after adjustment for NT-proBNP and cTnT. Compared with normal subjects (FEV1/FVC ≥0.70 and FVC≥80%), moderate or severe (FEV1/FVC <0.70 and FEV1 <80%) airflow obstruction was independently associated with HF ((adjusted relative risk 1.59 (1.08 to 2.33)). Airflow restriction (FEV1/FVC ≥0.70 and FVC <80%) was not independently associated with HF. Conclusions Reduced FEV1 reflecting airflow obstruction is associated with cardiac dysfunction and increased risk of incident HF in older men. PMID:26811343

  8. [Lung dysfunction in patients with severe chronic obstructive bronchitis].

    PubMed

    Nefedov, V B; Popova, L A; Shergina, E A

    2005-01-01

    VC, FVC, FEV1, FEV1/VC%, PEF, MEF25, MEF50, MEF75, TCL, TGV, RV, Raw, Rin, Rex, DLCO-SS, PaO2, and PaCO2 were determined in 36 patients with severe chronic obstructive lung disease (FEV1 < 50% of the normal value). All the patients were found to have impaired bronchial patency and changes in lung volumes and capacities; 83.3% of the patients had pulmonary gas exchange dysfunction. Impaired bronchial patency mainly appeared as decreased FEV1, FEV1/VC%, PEF, MEF25, MEF50, MEF75, Raw, Rin, Rex; altered lung volumes and capacities manifested by increased RV, TGV, and TLC, and by decreased VC and FVC; pulmonary gas exchange dysfunction showed up as lowered PaO2 and DLCO-SS, as decreased or increased PaCO2. The observed bronchial patency disorders varied from significant to severe; functional changes in lung volumes and capacities were mild to severe.

  9. The association between anthropometric measures and lung function in a population-based study of Canadian adults.

    PubMed

    Rowe, A; Hernandez, P; Kuhle, S; Kirkland, S

    2017-10-01

    Decreased lung function has health impacts beyond diagnosable lung disease. It is therefore important to understand the factors that may influence even small changes in lung function including obesity, physical fitness and physical activity. The aim of this study was to determine the anthropometric measure most useful in examining the association with lung function and to determine how physical activity and physical fitness influence this association. The current study used cross-sectional data on 4662 adults aged 40-79 years from the Canadian Health Measures Survey Cycles 1 and 2. Linear regression models were used to examine the association between the anthropometric and lung function measures (forced expiratory volume in 1 s [FEV 1 ] and forced vital capacity [FVC]); R 2 values were compared among models. Physical fitness and physical activity terms were added to the models and potential confounding was assessed. Models using sum of 5 skinfolds and waist circumference consistently had the highest R 2 values for FEV 1 and FVC, while models using body mass index consistently had among the lowest R 2 values for FEV 1 and FVC and for men and women. Physical activity and physical fitness were confounders of the relationships between waist circumference and the lung function measures. Waist circumference remained a significant predictor of FVC but not FEV 1 after adjustment for physical activity or physical fitness. Waist circumference is an important predictor of lung function. Physical activity and physical fitness should be considered as potential confounders of the relationship between anthropometric measures and lung function. Copyright © 2017. Published by Elsevier Ltd.

  10. Association between the Type of Workplace and Lung Function in Copper Miners

    PubMed Central

    Gruszczyński, Leszek; Wojakowska, Anna; Ścieszka, Marek; Turczyn, Barbara; Schmidt, Edward

    2016-01-01

    The aim of the analysis was to retrospectively assess changes in lung function in copper miners depending on the type of workplace. In the groups of 225 operators, 188 welders, and 475 representatives of other jobs, spirometry was performed at the start of employment and subsequently after 10, 20, and 25 years of work. Spirometry Longitudinal Data Analysis software was used to estimate changes in group means for FEV1 and FVC. Multiple linear regression analysis was used to assess an association between workplace and lung function. Lung function assessed on the basis of calculation of longitudinal FEV1 (FVC) decline was similar in all studied groups. However, multiple linear regression model used in cross-sectional analysis revealed an association between workplace and lung function. In the group of welders, FEF75 was lower in comparison to operators and other miners as early as after 10 years of work. Simultaneously, in smoking welders, the FEV1/FVC ratio was lower than in nonsmokers (p < 0,05). The interactions between type of workplace and smoking (p < 0,05) in their effect on FVC, FEV1, PEF, and FEF50 were shown. Among underground working copper miners, the group of smoking welders is especially threatened by impairment of lung ventilatory function. PMID:27274987

  11. Spirometry: predicting risk and outcome.

    PubMed

    Brunelli, Alessandro; Rocco, Gaetano

    2008-02-01

    Predicted postoperative FEV1 is certainly the most widely used parameter in preoperative risk stratification [54] and the measure recommend by BTS and ACCP functional guidelines as a first step in the screening of patients for lung resection surgery. Nevertheless, recent evidences have demonstrated that ppoFEV1 is not a reliable predictor of postoperative cardiopulmonary complications in patients with preoperative impaired pulmonary function. This may be because of the fact that the resection of a portion of lung in patients with obstructive disease determines only a minimal loss, or even an improvement, in overall respiratory function and exercise tolerance. This lung volume reduction effect takes place very early, since the first postoperative days, balancing what ever negative physiologic effects a thoracotomy and lung resection may entail. In addition to its poor predictive role in COPD patients, ppoFEV1 largely underestimate the actual loss in the very first days after operation, when most of the complications develop. The rationale to use a parameter which is poorly correlated with the pulmonary function at the moment the complications occur seems unwarranted. At the very best, ppoFEV1 appears a weak surrogate of the immediate postoperative FEV1. The FEV1 measured on the first postoperative day may be 30% less than predicted. Corrective equations have been published to correct this discrepancy with the aim to improve risk stratification.

  12. Longitudinal decline in lung function measurements among Saskatchewan grain workers.

    PubMed

    Pahwa, Punam; Senthilselvan, Ambikaipakan; McDuffie, Helen H; Dosman, James A

    2003-04-01

    To evaluate the relationship between the long term effects of grain dust and decline in lung function among grain elevator workers in Saskatchewan, studied over a 15-year period. The Grain Dust Medical Surveillance Program was started by Labour Canada in 1978 and longitudinally studied the respiratory health of Canadian grain elevator workers over a 15-year period (1978 to 1993). Data on respiratory symptoms and pulmonary function tests (forced expiratory volume in 1 s [FEV1], forced vital capacity [FVC]) were collected once every three years; each three-year interval was called a 'cycle'. Data from Saskatchewan were analyzed for this report. A transitional model using the generalized estimating equations approach was fitted using a SAS macro to predict the annual decline in FEV1 and FVC. Previous lung function, as one of the covariates in the transitional model, played an important role. Significant predictors of FEV1 were previous FEV1, base height, weight, years in the grain industry, current smoking status, cycle II, cycle III and cycle V. Significant predictors of FVC were previous FVC, base height, weight, years in the grain industry, cycle II, cycle III and cycle IV. The estimated annual decline in FEV1 and FVC increased according to length of time in the grain industry among nonsmoking, ex-smoking and smoking grain elevator workers. Lung function values improved after dust control, and yearly declines in FEV1 and FVC after dust control were smaller compared with yearly losses before dust control.

  13. Reference percentiles of FEV1 for the Canadian cystic fibrosis population: comparisons across time and countries.

    PubMed

    Kim, Sang-Ook; Corey, Mary; Stephenson, Anne L; Strug, Lisa J

    2018-05-01

    Forced expiratory volume in 1 s (FEV1) indicates lung health in cystic fibrosis (CF). FEV1 is commonly communicated as a per cent predicted of a healthy individual sharing the same age, sex, race and height. CF-specific reference equations are complementary and calibrate a patient's FEV1 to that of their CF peers. (1) To derive Canadian CF-specific FEV1 reference percentiles (FEV1%iles), (2) characterize how they have changed over time and (3) compare the Canadian FEV1%iles to those for USA and European CF populations. CF FEV1%iles are calculated using the Canadian CF Registry and quantile regression. The Canadian FEV1%iles demonstrated better lung function in more recent time periods within Canada, especially below the 50% percentile and in males. When compared to USA and European FEV1%iles for the same time period, Canadian FEV1%iles were higher. CF-specific FEV1%iles can provide useful information about changes in lung health. An online calculator (available at cfpercentile. sickkids.ca) makes these FEV1%iles accessible. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. South African and international reference values for lung function and its relationship with blood pressure in Africans.

    PubMed

    van Rooyen, Yolandi; Huisman, Hugo W; Schutte, Aletta E; Eloff, Fritz C; Du Plessis, Johan L; Kruger, Annamarie; Van Rooyen, Johannes M

    2015-06-01

    In South Africa respiratory diseases are highly prevalent, with cardiovascular disease being a manifestation. However, international reference values for lung function are commonly used, which may not be appropriate to correctly identify reduced lung function. An inverse relationship exists between lung function and blood pressure (BP) but is not investigated extensively in black South Africans. We included 2010 Africans from the PURE (Prospective Urban Rural Epidemiology) study (aged > 35 years) in the North West Province. Spirometry was performed and predicted values for forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) were calculated from South African, European and United States prediction equations. With the exception of the European predicted values, all other predicted mean FEV1 and FVC were above 80%. South African reference values displayed the highest percentages of the predicted values for FEV1 and FVC (87.9 and 99.7%, respectively.) BP increased from quintiles five to one for both FEV1 and FVC, (p for trend <0.001). After adjustment the differences remained (p<0.05). South African reference values yielded higher percentages of predicted FEV1 and FVC values than European and US equations suggesting that South African prediction equations may be more useful when investigating lung function in black South Africans. Elevated BP is related to reduced lung function, highlighting the importance in managing both respiratory- and cardiovascular disease. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  15. Fibroblast growth factor 10 haploinsufficiency causes chronic obstructive pulmonary disease.

    PubMed

    Klar, Joakim; Blomstrand, Peter; Brunmark, Charlott; Badhai, Jitendra; Håkansson, Hanna Falk; Brange, Charlotte Sollie; Bergendal, Birgitta; Dahl, Niklas

    2011-10-01

    Genetic factors influencing lung function may predispose to chronic obstructive pulmonary disease (COPD). The fibroblast growth factor 10 (FGF10) signalling pathway is critical for lung development and lung epithelial renewal. The hypothesis behind this study was that constitutive FGF10 insufficiency may lead to pulmonary disorder. Therefore investigation of the pulmonary functions of patients heterozygous for loss of function mutations in the FGF10 gene was performed. The spirometric measures of lung function from patients and non-carrier siblings were compared and both groups were related to matched reference data for normal human lung function. The patients show a significant decrease in lung function parameters when compared to control values. The average FEV1/IVC quota (FEV1%) for the patients is 0.65 (80% of predicted) and reversibility test using Terbutalin resulted in a 3.7% increase in FEV1. Patients with FGF10 haploinsufficiency have lung function parameters indicating COPD. A modest response to Terbutalin confirms an irreversible obstructive lung disease. These findings support the idea that genetic variants affecting the FGF10 signalling pathway are important determinants of lung function that may ultimately contribute to COPD. Specifically, the results show that FGF10 haploinsufficiency affects lung function measures providing a model for a dosage sensitive effect of FGF10 in the development of COPD.

  16. Spirometry: a predictor of lung cancer among asbestos workers.

    PubMed

    Świątkowska, Beata; Szeszenia-Dąbrowska, Neonila

    2017-01-01

    The significance of lung function as an independent risk factor for lung cancer remains unclear. The objective of the study is to answer the question if spirometry can identify patients at risk for lung cancer among people occupationally exposed to asbestos dust in the past. In order to identify a group of individuals with the highest risk of lung cancer incidence based on lung function levels of FEV 1 % predicted value, we examined 6882 subjects enrolled in the health surveillance program for asbestos related diseases over the years 2000-2014. We found a total of 110 cases confirmed as primary lung cancer. Using Cox's proportional hazards model after adjustment for age, gender, number of cigarettes, duration of smoking and cumulative asbestos exposure, we estimated that compared with the subjects with FEV 1 ≥90% pred, the HR of lung cancer was 1.40 (95%CI: 0.94-2.08) for the subjects with FEV 1 less than 90% and 1.95 (HR = 1.86; 95%CI: 1.12-3.08) for those with FEV 1 less than 70%. In addition, probability of the occurrence of lung cancer for FEV 1 <90% of the predicted value was HR = 2.19 (95%CI: 1.04-4.61) in the subjects whose time since spirometry and cancer diagnosis was three years or less. The results strongly support the hypothesis that spirometry can identify patients at a risk of lung cancer development. Regular spirometry should be offered to all patients with a history of asbestos exposure, at least once every three years.

  17. Lung function changes in coke oven workers during 12 years of follow up

    PubMed Central

    Wu, J; Griffiths, D; Kreis, I; Darling, C

    2004-01-01

    Aims: To investigate the effect of exposure to coke oven emissions on the lung function of coke oven workers. Methods: The study population, followed from 1978 and 1990, was 580 male workers with at least two sets of lung function measurements (FVC, FEV1, FEV1/FVC, and FEF25–75%). An annual rate of change (time slope) for age and height adjusted lung function index was estimated for each subject. This "time slope" was then treated as the response variable in a weighted multiple regression analysis with selected predictors. Results: For all 580 subjects, each year of working in the "operation" group (the most exposed) was found to increase the FVC decline by around 0.7 ml/year (95% CI 0.1 to 1.3 ml/year). After the exclusion of 111 subjects without detailed work history, the above finding was confirmed and each year of exposure in "operation" was also found to increase the FEV1 decline by around 0.8 ml/year (95% CI 0.1 to 1.4 ml/year). Conclusions: These findings are consistent with the results of previous cross-sectional studies. Work duration in the most exposed position in the coke ovens was associated with increased annual decline for FVC and FEV1. The estimated effect of one year of work exposure in "operation" is equivalent, in terms of the reduction in lung function, to an estimated 2.1 pack-years of smoking for FVC and 1.2 pack-years of smoking for FEV1. PMID:15258275

  18. Infection, inflammation, and lung function decline in infants with cystic fibrosis.

    PubMed

    Pillarisetti, Naveen; Williamson, Elizabeth; Linnane, Barry; Skoric, Billy; Robertson, Colin F; Robinson, Phil; Massie, John; Hall, Graham L; Sly, Peter; Stick, Stephen; Ranganathan, Sarath

    2011-07-01

    Better understanding of evolution of lung function in infants with cystic fibrosis (CF) and its association with pulmonary inflammation and infection is crucial in informing both early intervention studies aimed at limiting lung damage and the role of lung function as outcomes in such studies. To describe longitudinal change in lung function in infants with CF and its association with pulmonary infection and inflammation. Infants diagnosed after newborn screening or clinical presentation were recruited prospectively. FVC, forced expiratory volume in 0.5 seconds (FEV(0.5)), and forced expiratory flows at 75% of exhaled vital capacity (FEF(75)) were measured using the raised-volume technique, and z-scores were calculated from published reference equations. Pulmonary infection and inflammation were measured in bronchoalveolar lavage within 48 hours of lung function testing. Thirty-seven infants had at least two successful repeat lung function measurements. Mean (SD) z-scores for FVC were -0.8 (1.0), -0.9 (1.1), and -1.7 (1.2) when measured at the first visit, 1-year visit, or 2-year visit, respectively. Mean (SD) z-scores for FEV(0.5) were -1.4 (1.2), -2.4 (1.1), and -4.3 (1.6), respectively. In those infants in whom free neutrophil elastase was detected, FVC z-scores were 0.81 lower (P=0.003), and FEV(0.5) z-scores 0.96 lower (P=0.001), respectively. Significantly greater decline in FEV(0.5) z-scores occurred in those infected with Staphylococcus aureus (P=0.018) or Pseudomonas aeruginosa (P=0.021). In infants with CF, pulmonary inflammation is associated with lower lung function, whereas pulmonary infection is associated with a greater rate of decline in lung function. Strategies targeting pulmonary inflammation and infection are required to prevent early decline in lung function in infants with CF.

  19. [Impaired lung function in patients with moderate chronic obstructive bronchitis].

    PubMed

    Nefedov, V B; Popova, L A; Shergina, E A

    2004-01-01

    VC, FVC, FEV1, FEV1/VC%, PEF, MEF25, MEF50, MEF75, TLC, TGV, RV, Raw, Rin, Rex, DLCO-SS, paO2 and paCO2 were determined in 22 patients with moderate chronic obstructive bronchitis (FEV1, 79-50% of the normal value). All the patients were found to have impaired bronchial patency, 90.9% of the patients had lung volume and capacity changes; pulmonary gas exchange dysfunction was present in 72.7%. Bronchial patency impairments were manifested by a decrease in FEV1, FEV1/VC%, PEF, MEF25, MEF50, MEF75, and an increase in Raw, Rin, Rex. Changes in the lung volumes and capacities appeared as higher RV, TGV, TLC, lower VC and FVC. Pulmonary gas exchange dysfunction showed up as a reduction in pO2 and DLCO-SS a reduction and an increase in paCO2. The magnitude of the functional changes observed in most patients was low. Significant and pronounced disorders were seen in one third of the patients.

  20. Long-term exposure to diesel engine exhaust induced lung function decline in a cross sectional study

    PubMed Central

    ZHANG, Li Ping; ZHANG, Xiao; DUAN, Hua Wei; MENG, Tao; NIU, Yong; HUANG, Chuan Feng; GAO, Wei Min; YU, Shan Fa; ZHENG, Yu Xin

    2016-01-01

    To clarify the effects of lung function following exposure to diesel engine exhaust (DEE), we recruited 137 diesel engine testing workers exposed to DEE and 127 non-DEE-exposed workers as study subjects. We performed lung function tests and measured cytokinesis-block micronucleus (CBMN) cytome index and levels of urinary polycyclic aromatic hydrocarbons (PAHs) metabolites. There was a significant decrease of forced expiratory volume in 1 second (FEV1), ratio of forced expiratory volume in 1 second to forced vital capacity (FEV1/ FVC), maximal mid expiratory flow curve (MMF), forced expiratory flow at 50% of FVC (FEF50%), and forced expiratory flow at 75% of FVC (FEF75%) in the DEE-exposed workers than non-DEE-exposed workers (all p<0.05). Among all study subjects, the decreases of FEF75% were associated with the increasing levels of PAHs metabolites (p<0.05), and there were negative correlations between FEV1, FEV1/FVC, MMF, FEF50%, and FEF75% with CBMN cytome index (all p<0.05). Our results show that long-term exposure to DEE can induce lung function decline which shows mainly obstructive changes and influence of small airways function. The decreased lung function is associated with internal dosage of DEE exposure, and accompany with the increasing CBMN cytome index. PMID:27334424

  1. Metabolic Syndrome Biomarkers Predict Lung Function Impairment

    PubMed Central

    Naveed, Bushra; Weiden, Michael D.; Kwon, Sophia; Gracely, Edward J.; Comfort, Ashley L.; Ferrier, Natalia; Kasturiarachchi, Kusali J.; Cohen, Hillel W.; Aldrich, Thomas K.; Rom, William N.; Kelly, Kerry; Prezant, David J.

    2012-01-01

    Rationale: Cross-sectional studies demonstrate an association between metabolic syndrome and impaired lung function. Objectives: To define if metabolic syndrome biomarkers are risk factors for loss of lung function after irritant exposure. Methods: A nested case-control study of Fire Department of New York personnel with normal pre–September 11th FEV1 and who presented for subspecialty pulmonary evaluation before March 10, 2008. We correlated metabolic syndrome biomarkers obtained within 6 months of World Trade Center dust exposure with subsequent FEV1. FEV1 at subspecialty pulmonary evaluation within 6.5 years defined disease status; cases had FEV1 less than lower limit of normal, whereas control subjects had FEV1 greater than or equal to lower limit of normal. Measurements and Main Results: Clinical data and serum sampled at the first monitoring examination within 6 months of September 11, 2001, assessed body mass index, heart rate, serum glucose, triglycerides and high-density lipoprotein (HDL), leptin, pancreatic polypeptide, and amylin. Cases and control subjects had significant differences in HDL less than 40 mg/dl with triglycerides greater than or equal to 150 mg/dl, heart rate greater than or equal to 66 bpm, and leptin greater than or equal to 10,300 pg/ml. Each increased the odds of abnormal FEV1 at pulmonary evaluation by more than twofold, whereas amylin greater than or equal to 116 pg/ml decreased the odds by 84%, in a multibiomarker model adjusting for age, race, body mass index, and World Trade Center arrival time. This model had a sensitivity of 41%, a specificity of 86%, and a receiver operating characteristic area under the curve of 0.77. Conclusions: Abnormal triglycerides and HDL and elevated heart rate and leptin are independent risk factors of greater susceptibility to lung function impairment after September 11, 2001, whereas elevated amylin is protective. Metabolic biomarkers are predictors of lung disease, and may be useful for assessing risk of impaired lung function in response to particulate inhalation. PMID:22095549

  2. Farm environment during infancy and lung function at the age of 31: a prospective birth cohort study in Finland.

    PubMed

    Lampi, Jussi; Koskela, Heikki; Hartikainen, Anna-Liisa; Ramasamy, Adaikalavan; Couto Alves, Alexessander; Järvelin, Marjo-Riitta; Pekkanen, Juha

    2015-07-22

    Farming as an occupation is considered a risk factor for asthma and reduced lung function. By contrast, living on a farm during infancy has been reported to be associated with lower risk of asthma in adulthood. However, little is known about the association between farming environment during infancy and lung function in adulthood. We aimed to study the prospective longitudinal association between farming environment during infancy and lung function in adulthood. A prospective birth cohort study. Northern Finland. 5666 participants born in 1966 were followed up at the age of 31 years. Spirometry at the age of 31 years. To be born into a farmer's family was associated with higher forced expiratory volume in 1 s (FEV1) (36 mL; 95% CI 6 to 67 mL) and forced vital capacity (FVC) (40 mL; 95% CI 5 to 75 mL) at the age of 31 years. Contact with farm animals during infancy was associated with higher FEV1. No associations were seen with FEV1/FVC (FEV1/FVC ratio). Having dogs in childhood revealed similar associations. There was a suggestive dose-dependent association with the number of animal species during childhood and higher FEV1 and FVC at adulthood, especially among women. Farming environment in early life may have a positive impact on lung function in adulthood. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Disparities in pulmonary function in healthy children across the Indian urban-rural continuum.

    PubMed

    Sonnappa, Samatha; Lum, Sooky; Kirkby, Jane; Bonner, Rachel; Wade, Angela; Subramanya, Vinita; Lakshman, Padmanabha T; Rajan, Babitha; Nooyi, Shalini C; Stocks, Janet

    2015-01-01

    Marked socioeconomic health-care disparities are recognized in India, but lung health inequalities between urban and rural children have not been studied. We investigated whether differences exist in spirometric pulmonary function in healthy children across the Indian urban-rural continuum and compared results with those from Indian children living in the UK. Indian children aged 5 to 12 years were recruited from Indian urban, semiurban, and rural schools, and as part of the Size and Lung Function in Children study, London. Anthropometric and spirometric assessments were undertaken. Acceptable spirometric data were obtained from 728 (58% boys) children in India and 311 (50% boys) UK-Indian children. As an entire group, the India-resident children had significantly lower z FEV1 and z FVC than UK-Indian children (P < 0.0005), when expressed using Global Lung Function Initiative-2012 equations. However, when India-resident children were categorized according to residence, there were no differences in z FEV1 and z FVC between Indian-urban and UK-Indian children. There were, however, significant reductions of ∼ 0.5 z scores and 0.9 z scores in both FEV1 and FVC (with no difference in FEV1/FVC) in Indian-semiurban and Indian-rural children, respectively, when compared with Indian-urban children (P < 0.0005). z Body mass index, socioeconomic circumstances, tobacco, and biomass exposure were individually significantly associated with z FEV1 and z FVC (P < 0.0005). The presence of an urban-rural continuum of lung function within a specific ethnic group emphasizes the impact of environmental factors on lung growth in emerging nations such as India, which must be taken into account when developing ethnic-specific reference values or designing studies to optimize lung health.

  4. A prospective study of decline in lung function in relation to welding emissions.

    PubMed

    Christensen, Sigve W; Bonde, Jens Peter; Omland, Oyvind

    2008-02-26

    Numerous cross-sectional studies have reported reduced lung function among welders but limitations of exposure assessment and design preclude causal inference. The aim of this study was to investigate if long-term exposure to welding fume particulates accelerates the age-related decline in lung function. Lung function was measured by spirometry in 1987 and 2004 among 68 steel welders and 32 non-welding production workers. The decline in forced expiratory volume (FEV1) was analysed in relation to cumulated exposure to fume particulates among welders during the follow-up period. Among smokers the decline in FEV1 through follow-up period was in average 150 ml larger among welders than non-welders while the difference was negligible among non-smokers. The results did not reach statistical significance and within welders the decline in lung function was not related to the cumulated welding particulate exposure during follow-up period Long-term exposure to welding emissions may accelerate the age-related decline of lung function but at exposure levels in the range of 1.5 to 6.5 mg/m3 the average annual excess loss of FEV1 is unlikely to exceed 25 ml in smokers and 10 ml in non-smokers.

  5. Insulin resistance, metabolic syndrome, and lung function in US adolescents with and without asthma.

    PubMed

    Forno, Erick; Han, Yueh-Ying; Muzumdar, Radhika H; Celedón, Juan C

    2015-08-01

    Obesity increases both the risk of asthma and asthma severity and is a well-known risk factor for insulin resistance and the metabolic syndrome (MS) in children and adolescents. We aimed to examine the association among obesity, insulin sensitivity, MS, and lung function in US adolescents with and without asthma. We performed a cross-sectional study of 1429 adolescents aged 12 to 17 years in the 2007-2010 National Health and Nutrition Examination Survey. Adjusted regression was used to assess the relationships among obesity, insulin sensitivity/resistance, MS, and lung function in children with and without asthma. Insulin resistance was negatively associated with FEV1 and forced vital capacity (FVC) in adolescents with and without asthma, whereas MS was associated with lower FEV1/FVC ratios, with a more pronounced decrease found among asthmatic patients; these associations were driven by overweight/obese adolescents. Higher body mass index was associated with a decrease in FEV1/FVC ratios among adolescents with insulin resistance. Compared with healthy participants, adolescents with MS had an approximately 2% decrease in FEV1/FVC ratios, adolescents with asthma had an approximately 6% decrease, and those with MS and asthma had approximately 10% decreased FEV1/FVC ratios (P < .05). Insulin resistance and MS are associated with worsened lung function in overweight/obese adolescents. Asthma and MS synergistically decrease lung function, as do obesity and insulin resistance. These factors might contribute to the pathogenesis of asthma severity in obese patients and warrant further investigation. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  6. Association between pulmonary function and renal function: findings from China and Australia.

    PubMed

    Yu, Dahai; Chen, Tao; Cai, Yamei; Zhao, Zhanzheng; Simmons, David

    2017-05-01

    The relationship between obstructive lung function and impaired renal function is unclear. This study investigated the dose-response relationship between obstructive lung function and impaired renal function. Two independent cross-sectional studies with representative sampling were applied. 1454 adults from rural Victoria, Australia (1298 with normal renal function, 156 with impaired renal function) and 5824 adults from Nanjing, China (4313 with normal renal function, 1511 with impaired renal function). Pulmonary function measurements included forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). Estimated glomerular filtration rate (eGFR), and impaired renal function marked by eGFR <60 mL/min/1.73m 2 were used as outcome. eGFR increased linearly with FEV1 in Chinese participants and with FVC in Australians. A non-linear relationship with peaked eGFR was found for FEV1 at 2.65 L among Australians and for FVC at 2.78 L among Chinese participants, respectively. A non-linear relationship with peaked eGFR was found for the predicted percentage value of forced expiratory volume in 1 s (PFEV1) at 81-82% and for the predicted percentage value of forced vital capacity (PFVC) at 83-84% among both Chinese and Australian participants, respectively. The non-linear dose-response relationships between lung capacity measurements (both for FEV1 and FVC) and risk of impaired renal function were consistently identified in both Chinese and Australian participants. An increased risk of impaired renal function was found below 3.05 L both for FEV1 and FVC, respectively. The non-linear relationship between PFEV and PVC and the risk of impaired renal function were consistently identified in both Chinese and Australian participants. An increased risk of impaired renal function was found below 76-77% for PFEV1 and 79-80% for PFVC, respectively. In both Australian and Chinese populations, the risk of impaired renal function increased both with FEV1 and FVC below 3.05 L, with PFEV1 below 76-77% or with PFVC below 79-80%, respectively. Obstructive lung function was associated with increased risk of reduced renal function. The screen for impaired renal function in patients with obstructive lung disease might be useful to ensure there was no impaired renal function before the commencement of potentially nephrotoxic medication where indicated (eg diuretics).

  7. Lung clearance index is a repeatable and sensitive indicator of radiological changes in bronchiectasis.

    PubMed

    Rowan, Stephen A; Bradley, Judy M; Bradbury, Ian; Lawson, John; Lynch, Tom; Gustafsson, Per; Horsley, Alex; O'Neill, Katherine; Ennis, Madeleine; Elborn, J Stuart

    2014-03-01

    In bronchiectasis there is a need for improved markers of lung function to determine disease severity and response to therapy. To assess whether the lung clearance index is a repeatable and more sensitive indicator of computed tomography (CT) scan abnormalities than spirometry in bronchiectasis. Thirty patients with stable bronchiectasis were recruited and lung clearance index, spirometry, and health-related quality of life measures were assessed on two occasions, 2 weeks apart when stable (study 1). A separate group of 60 patients with stable bronchiectasis was studied on a single visit with the same measurements and a CT scan (study 2). In study 1, the intervisit intraclass correlation coefficient for the lung clearance index was 0.94 (95% confidence interval, 0.89 to 0.97; P < 0.001). In study 2, the mean age was 62 (10) years, FEV1 76.5% predicted (18.9), lung clearance index 9.1 (2.0), and total CT score 14.1 (10.2)%. The lung clearance index was abnormal in 53 of 60 patients (88%) and FEV1 was abnormal in 37 of 60 patients (62%). FEV1 negatively correlated with the lung clearance index (r = -0.51, P < 0.0001). Across CT scores, there was a relationship with the lung clearance index, with little evidence of an effect of FEV1. There were no significant associations between the lung clearance index or FEV1 and health-related quality of life. The lung clearance index is repeatable and a more sensitive measure than FEV1 in the detection of abnormalities demonstrated on CT scan. The lung clearance index has the potential to be a useful clinical and research tool in patients with bronchiectasis.

  8. Lung function impairment in women exposed to biomass fuels during cooking compared to cleaner fuels in Uttar Pradesh, India.

    PubMed

    Bihari, Vipin; Iqbal, S M; Srivastava, L P; Kesavachandran, C; Siddique, M J A

    2013-11-01

    A national survey has shown that approximately 75-80% use of fire wood and chips, 10% of dung cake rural women in Uttar Pradesh, India. Considering the respiratory health risk of biomass fuel exposure to women, a cross sectional study was conducted to elucidate the relationship between cooking smoke and lung function impairments. The present study showed significant decline in air flow limitation based on reduced PEFR (3.69 | sec(-1)) and FEV1 (1.34 | sec(-1)) in women cooking with biomass fuels compared to PEFR (4.26 | sec(-1)) and FEV1 (1.73 | sec(-1)) in women cooking with cleaner fuels. The noxious gases and particles generated from biomass fuels during cooking reported in earlier studies may be the reason for the slight decline in airway status PEFR (3.69 | sec(-1)) and lung volumes FEV1 (1.34 | sec(-1)). The higher mean bio-fuels exposure index (52.5 hr-yrs) can attribute to reduced lung function in rural women.

  9. Plasma pro-surfactant protein B and lung function decline in smokers.

    PubMed

    Leung, Janice M; Mayo, John; Tan, Wan; Tammemagi, C Martin; Liu, Geoffrey; Peacock, Stuart; Shepherd, Frances A; Goffin, John; Goss, Glenwood; Nicholas, Garth; Tremblay, Alain; Johnston, Michael; Martel, Simon; Laberge, Francis; Bhatia, Rick; Roberts, Heidi; Burrowes, Paul; Manos, Daria; Stewart, Lori; Seely, Jean M; Gingras, Michel; Pasian, Sergio; Tsao, Ming-Sound; Lam, Stephen; Sin, Don D

    2015-04-01

    Plasma pro-surfactant protein B (pro-SFTPB) levels have recently been shown to predict the development of lung cancer in current and ex-smokers, but the ability of pro-SFTPB to predict measures of chronic obstructive pulmonary disease (COPD) severity is unknown. We evaluated the performance characteristics of pro-SFTPB as a biomarker of lung function decline in a population of current and ex-smokers. Plasma pro-SFTPB levels were measured in 2503 current and ex-smokers enrolled in the Pan-Canadian Early Detection of Lung Cancer Study. Linear regression was performed to determine the relationship of pro-SFTPB levels to changes in forced expiratory volume in 1 s (FEV1) over a 2-year period as well as to baseline FEV1 and the burden of emphysema observed in computed tomography (CT) scans. Plasma pro-SFTPB levels were inversely related to both FEV1 % predicted (p=0.024) and FEV1/forced vital capacity (FVC) (p<0.001), and were positively related to the burden of emphysema on CT scans (p<0.001). Higher plasma pro-SFTPB levels were also associated with a more rapid decline in FEV1 at 1 year (p=0.024) and over 2 years of follow-up (p=0.004). Higher plasma pro-SFTPB levels are associated with increased severity of airflow limitation and accelerated decline in lung function. Pro-SFTPB is a promising biomarker for COPD severity and progression. Copyright ©ERS 2015.

  10. [Lung dysfunction in patients with mild chronic obstructive bronchitis].

    PubMed

    Nefedov, V B; Popova, L A; Shergina, E A

    2004-01-01

    VC, FVC, FEV1, FEV1/VC%, PEF, MEF25, MEF50, MEF75, TCL, TGV, RV, Ravt, Riin, Rex, DLCO-SS, PaO2, and PaO2 were determined in 33 patients with mild chronic obstructive lung disease (FEV1 > 70% of the normal value). All the patients were found to have impaired bronchial patency; most (63.6%) patients had lung volume and capacity changes, almost half (45.5%) the patients had pulmonary gas exchange dysfunction. Impaired bronchial patency mainly appeared as decreased MEF50, MEF15, and FEV1/VC%; altered lung volumes and capacities manifested chiefly by increased RV and decreased VC; pulmonary gas exchange dysfunction showed up primarily as lowered PaO2. The magnitude of the observed functional changes was generally slight. MEF50, MEF75, FEV1/VC%, and VC dropped to 59-20 and 79-70% of the normal value, respectively. RV increased up to 142-196% of the normal value; PaO2 reduced up to 79-60% mm Hg.

  11. Short-Term Exposure to Air Pollution and Lung Function in the Framingham Heart Study

    PubMed Central

    Ljungman, Petter L.; Wilker, Elissa H.; Gold, Diane R.; Schwartz, Joel D.; Koutrakis, Petros; Washko, George R.; O’Connor, George T.; Mittleman, Murray A.

    2013-01-01

    Rationale: Short-term exposure to ambient air pollution has been associated with lower lung function. Few studies have examined whether these associations are detectable at relatively low levels of pollution within current U.S. Environmental Protection Agency (EPA) standards. Objectives: To examine exposure to ambient air pollutants within EPA standards and lung function in a large cohort study. Methods: We included 3,262 participants of the Framingham Offspring and Third Generation cohorts living within 40 km of the Harvard Supersite monitor in Boston, Massachusetts (5,358 examinations, 1995–2011) who were not current smokers, with previous-day pollutant levels in compliance with EPA standards. We compared lung function (FEV1 and FVC) after previous-day exposure to particulate matter less than 2.5 μm in diameter (PM2.5), nitrogen dioxide (NO2), and ozone (O3) in the “moderate” range of the EPA Air Quality Index to exposure in the “good” range. We also examined linear relationships between moving averages of pollutant concentrations 1, 2, 3, 5, and 7 days before spirometry and lung function. Measurements and Main Results: Exposure to pollutant concentrations in the “moderate” range of the EPA Air Quality Index was associated with a 20.1-ml lower FEV1 for PM2.5 (95% confidence interval [CI], −33.4, −6.9), a 30.6-ml lower FEV1 for NO2 (95% CI, −60.9, −0.2), and a 55.7-ml lower FEV1 for O3 (95% CI, −100.7, −10.8) compared with the “good” range. The 1- and 2-day moving averages of PM2.5, NO2, and O3 before testing were negatively associated with FEV1 and FVC. Conclusions: Short-term exposure to PM2.5, NO2, and O3 within current EPA standards was associated with lower lung function in this cohort of adults. PMID:24200465

  12. Lower lung function associates with cessation of menstruation: UK Biobank data.

    PubMed

    Amaral, André F S; Strachan, David P; Gómez Real, Francisco; Burney, Peter G J; Jarvis, Deborah L

    2016-11-01

    Little is known about the effect of cessation of menstruation on lung function. The aims of the study were to examine the association of lung function with natural and surgical cessation of menstruation, and assess whether lower lung function is associated with earlier age at cessation of menstruation.The study was performed in 141 076 women from the UK Biobank, who had provided acceptable and reproducible spirometry measurements and information on menstrual status. The associations of lung function (forced vital capacity (FVC), forced expiratory volume in 1 s (FEV 1 ), spirometric restriction (FVC < lower limit of normal (LLN)), airflow obstruction (FEV 1 /FVC

  13. Long-Term Exposure to Primary Traffic Pollutants and Lung Function in Children: Cross-Sectional Study and Meta-Analysis.

    PubMed

    Barone-Adesi, Francesco; Dent, Jennifer E; Dajnak, David; Beevers, Sean; Anderson, H Ross; Kelly, Frank J; Cook, Derek G; Whincup, Peter H

    2015-01-01

    There is widespread concern about the possible health effects of traffic-related air pollution. Nitrogen dioxide (NO2) is a convenient marker of primary pollution. We investigated the associations between lung function and current residential exposure to a range of air pollutants (particularly NO2, NO, NOx and particulate matter) in London children. Moreover, we placed the results for NO2 in context with a meta-analysis of published estimates of the association. Associations between primary traffic pollutants and lung function were investigated in 4884 children aged 9-10 years who participated in the Child Heart and Health Study in England (CHASE). A systematic literature search identified 13 studies eligible for inclusion in a meta-analysis. We combined results from the meta-analysis with the distribution of the values of FEV1 in CHASE to estimate the prevalence of children with abnormal lung function (FEV1<80% of predicted value) expected under different scenarios of NO2 exposure. In CHASE, there were non-significant inverse associations between all pollutants except ozone and both FEV1 and FVC. In the meta-analysis, a 10 μg/m3 increase in NO2 was associated with an 8 ml lower FEV1 (95% CI: -14 to -1 ml; p: 0.016). The observed effect was not modified by a reported asthma diagnosis. On the basis of these results, a 10 μg/m3 increase in NO2 level would translate into a 7% (95% CI: 4% to 12%) increase of the prevalence of children with abnormal lung function. Exposure to traffic pollution may cause a small overall reduction in lung function and increase the prevalence of children with clinically relevant declines in lung function.

  14. Influence of Lung Function and Sleep-disordered Breathing on All-Cause Mortality. A Community-based Study.

    PubMed

    Putcha, Nirupama; Crainiceanu, Ciprian; Norato, Gina; Samet, Jonathan; Quan, Stuart F; Gottlieb, Daniel J; Redline, Susan; Punjabi, Naresh M

    2016-10-15

    Whether sleep-disordered breathing (SDB) severity and diminished lung function act synergistically to heighten the risk of adverse health outcomes remains a topic of significant debate. The current study sought to determine whether the association between lower lung function and mortality would be stronger in those with increasing severity of SDB in a community-based cohort of middle-aged and older adults. Full montage home sleep testing and spirometry data were analyzed on 6,173 participants of the Sleep Heart Health Study. Proportional hazards models were used to calculate risk for all-cause mortality, with FEV 1 and apnea-hypopnea index (AHI) as the primary exposure indicators along with several potential confounders. All-cause mortality rate was 26.9 per 1,000 person-years in those with SDB (AHI ≥5 events/h) and 18.2 per 1,000 person-years in those without (AHI <5 events/h). For every 200-ml decrease in FEV 1 , all-cause mortality increased by 11.0% in those without SDB (hazard ratio, 1.11; 95% confidence interval, 1.08-1.13). In contrast, for every 200-ml decrease in FEV 1 , all-cause mortality increased by only 6.0% in participants with SDB (hazard ratio, 1.06; 95% confidence interval, 1.04-1.09). Additionally, the incremental influence of lung function on all-cause mortality was less with increasing severity of SDB (P value for interaction between AHI and FEV 1 , 0.004). Lung function was associated with risk for all-cause mortality. The incremental contribution of lung function to mortality diminishes with increasing severity of SDB.

  15. Influence of Lung Function and Sleep-disordered Breathing on All-Cause Mortality. A Community-based Study

    PubMed Central

    Putcha, Nirupama; Crainiceanu, Ciprian; Norato, Gina; Samet, Jonathan; Quan, Stuart F.; Gottlieb, Daniel J.; Redline, Susan

    2016-01-01

    Rationale: Whether sleep-disordered breathing (SDB) severity and diminished lung function act synergistically to heighten the risk of adverse health outcomes remains a topic of significant debate. Objectives: The current study sought to determine whether the association between lower lung function and mortality would be stronger in those with increasing severity of SDB in a community-based cohort of middle-aged and older adults. Methods: Full montage home sleep testing and spirometry data were analyzed on 6,173 participants of the Sleep Heart Health Study. Proportional hazards models were used to calculate risk for all-cause mortality, with FEV1 and apnea–hypopnea index (AHI) as the primary exposure indicators along with several potential confounders. Measurements and Main Results: All-cause mortality rate was 26.9 per 1,000 person-years in those with SDB (AHI ≥5 events/h) and 18.2 per 1,000 person-years in those without (AHI <5 events/h). For every 200-ml decrease in FEV1, all-cause mortality increased by 11.0% in those without SDB (hazard ratio, 1.11; 95% confidence interval, 1.08–1.13). In contrast, for every 200-ml decrease in FEV1, all-cause mortality increased by only 6.0% in participants with SDB (hazard ratio, 1.06; 95% confidence interval, 1.04–1.09). Additionally, the incremental influence of lung function on all-cause mortality was less with increasing severity of SDB (P value for interaction between AHI and FEV1, 0.004). Conclusions: Lung function was associated with risk for all-cause mortality. The incremental contribution of lung function to mortality diminishes with increasing severity of SDB. PMID:27105053

  16. Individualized prediction of lung-function decline in chronic obstructive pulmonary disease

    PubMed Central

    Zafari, Zafar; Sin, Don D.; Postma, Dirkje S.; Löfdahl, Claes-Göran; Vonk, Judith; Bryan, Stirling; Lam, Stephen; Tammemagi, C. Martin; Khakban, Rahman; Man, S.F. Paul; Tashkin, Donald; Wise, Robert A.; Connett, John E.; McManus, Bruce; Ng, Raymond; Hollander, Zsuszanna; Sadatsafavi, Mohsen

    2016-01-01

    Background: The rate of lung-function decline in chronic obstructive pulmonary disease (COPD) varies substantially among individuals. We sought to develop and validate an individualized prediction model for forced expiratory volume at 1 second (FEV1) in current smokers with mild-to-moderate COPD. Methods: Using data from a large long-term clinical trial (the Lung Health Study), we derived mixed-effects regression models to predict future FEV1 values over 11 years according to clinical traits. We modelled heterogeneity by allowing regression coefficients to vary across individuals. Two independent cohorts with COPD were used for validating the equations. Results: We used data from 5594 patients (mean age 48.4 yr, 63% men, mean baseline FEV1 2.75 L) to create the individualized prediction equations. There was significant between-individual variability in the rate of FEV1 decline, with the interval for the annual rate of decline that contained 95% of individuals being −124 to −15 mL/yr for smokers and −83 to 15 mL/yr for sustained quitters. Clinical variables in the final model explained 88% of variation around follow-up FEV1. The C statistic for predicting severity grades was 0.90. Prediction equations performed robustly in the 2 external data sets. Interpretation: A substantial part of individual variation in FEV1 decline can be explained by easily measured clinical variables. The model developed in this work can be used for prediction of future lung health in patients with mild-to-moderate COPD. Trial registration: Lung Health Study — ClinicalTrials.gov, no. NCT00000568; Pan-Canadian Early Detection of Lung Cancer Study — ClinicalTrials.gov, no. NCT00751660 PMID:27486205

  17. The Association of Normal Range Glycated Hemoglobin with Restrictive Lung Pattern in the General Population

    PubMed Central

    Oh, Il Hwan; Park, Jung Hwan; Lee, Chang Hwa; Park, Joon-Sung

    2015-01-01

    Glycated hemoglobin (HbA1c) is an important diagnostic indicator of diabetes mellitus, and some authors have argued that it is related to impaired lung function in the diabetic population. However, there was rare study for association between lung function and HbA1c in the non-diabetic population. We investigated whether HbA1c below the diagnostic threshold is related to deficits in lung function. We analyzed biochemical and spirometry data from a nation-wide, population-based, case-control study (the KNHANES IV and V). Eligible as cases were all native Koreans aged 40 years or more with no medical illness. A total of 3670 participants were divided into 4 groups according to HbA1c (%) as follows: Group I (n = 842), ≥ 4.0 and ≤ 5.3; Group II (n = 833), > 5.3 and ≤ 5.5; Group III (n = 898), > 5.5 and ≤ 5.7; and Group IV (n = 1097), > 5.7 and ≤ 6.4. Group I had the greatest forced vital capacity (FVC, 96.3 ± 0.5% pred, P < 0.0001), forced expiratory volume per second (FEV1, 93.8 ± 0.5% pred, P < 0.0001) and FEV1/FVC (0.792 ± 0.003, P < 0.0001) compared with the other groups. Linear regression showed that HbA1c was closely related to FVC (β = -6.972154, P < 0.0001) and FEV1 (β = -5.591589, P < 0.0001), but not to FEV1/FVC. Logistic regression analysis revealed a significant association between HbA1c and a restrictive spirometric pattern (FVC < 80% pred., FEV1/FVC ≥ 0.70; OR = 3.772, 95% CI = 1.234-11.53), indicating that elevated HbA1c is closely associated with lung impairment in the non-diabetic population. In the healthy population, relatively high HbA1c level is associated with decrements of FVC and FEV1 and may be a reliable predictor of poor lung function, especially the restrictive pattern. PMID:25658743

  18. [Clinical and functional characteristics of patients prior to lung transplantation: report of experience at the Clínica Puerta de Hierro].

    PubMed

    Laporta, Rosalía; Ussetti, Piedad; Mora, Gema; López, Cristina; Gómez, David; de Pablo, Alicia; Lázaro, M Teresa; Carreño, M Cruz; Ferreiro, M José

    2008-08-01

    The time at which lung transplantation is indicated is determined by clinical and functional criteria that vary according to the particular disease. The aim of our study was to present the criteria according to which patients were placed on waiting lists for lung transplantation in our hospital. We analyzed retrospectively the clinical characteristics, lung function, heart function, and 6-minute walk test results of patients who had received a lung transplant in our hospital from January 2002 through September 2005. During the study period 100 lung transplants were performed. The mean age of the patients was 45 years (range, 15-67 years) and 57% were men. The diseases that most often led to a lung transplant were chronic obstructive pulmonary disease (COPD) (35%), pulmonary fibrosis (29%), and bronchiectasis (21%). Lung function values differed by disease: mean (SD) forced expiratory volume in 1 second (FEV1) was 20% (11%) and forced vital capacity (FVC) was 37% (15%) in patients with COPD; FEV1 was 41% (15%) and FVC, 40% (17%) in patients with pulmonary fibrosis; and FEV1 was 23% (7%) and FVC, 37% (10%) in patients with bronchiectasis. The patients who received lung transplants in our hospital were in advanced phases of their disease and met the inclusion criteria accepted by the various medical associations when they were placed on the waiting list.

  19. Genetic Ancestry-Smoking Interactions and Lung Function in African Americans: A Cohort Study

    PubMed Central

    Colangelo, Laura A.; Williams, L. Keoki; Sen, Saunak; Kritchevsky, Stephen B.; Meibohm, Bernd; Galanter, Joshua; Hu, Donglei; Gignoux, Christopher R.; Liu, Yongmei; Harris, Tamara B.; Ziv, Elad; Zmuda, Joseph; Garcia, Melissa; Leak, Tennille S.; Foreman, Marilyn G.; Smith, Lewis J.; Fornage, Myriam; Liu, Kiang; Burchard, Esteban G.

    2012-01-01

    Background Smoking tobacco reduces lung function. African Americans have both lower lung function and decreased metabolism of tobacco smoke compared to European Americans. African ancestry is also associated with lower pulmonary function in African Americans. We aimed to determine whether African ancestry modifies the association between smoking and lung function and its rate of decline in African Americans. Methodology/Principal Findings We evaluated a prospective ongoing cohort of 1,281 African Americans participating in the Health, Aging, and Body Composition (Health ABC) Study initiated in 1997. We also examined an ongoing prospective cohort initiated in 1985 of 1,223 African Americans in the Coronary Artery Disease in Young Adults (CARDIA) Study. Pulmonary function and tobacco smoking exposure were measured at baseline and repeatedly over the follow-up period. Individual genetic ancestry proportions were estimated using ancestry informative markers selected to distinguish European and West African ancestry. African Americans with a high proportion of African ancestry had lower baseline forced expiratory volume in one second (FEV1) per pack-year of smoking (−5.7 ml FEV1/ smoking pack-year) compared with smokers with lower African ancestry (−4.6 ml in FEV1/ smoking pack-year) (interaction P value  = 0.17). Longitudinal analyses revealed a suggestive interaction between smoking, and African ancestry on the rate of FEV1 decline in Health ABC and independently replicated in CARDIA. Conclusions/Significance African American individuals with a high proportion of African ancestry are at greater risk for losing lung function while smoking. PMID:22737244

  20. Association of the relative change in weight and body mass index with lung function in teenagers and adults with cystic fibrosis: Influence of gender and diabetes.

    PubMed

    Cano Megías, Marta; Guisado Vasco, Pablo; González Albarrán, Olga; Lamas Ferreiro, Adelaida; Máiz Carro, Luis

    2015-11-01

    Nutritional status is a prognostic factor in cystic fibrosis. Prevention of nutritional impairment and weigh loss are major clinical objectives because they are associated with worsening of lung function and increased mortality. To identify a potential relationship of clinical nutrition parameters, and their relative changes, with lung function (FEV1%) in a cohort of adolescent and adult patients with CF. A retrospective analysis of 64 patients older than 14years. Weight, height, BMI, and lung function data were collected at a period of disease stability, both in the year of the first abnormal oral glucose tolerance test (OGTT) and in the previous year. Relative changes in weight and BMI, and their relationship with FEV1%, were determined by linear regression and ANOVA tests; influence of gender and diabetes was also assessed. Mean age of the series (28 females and 36 males) was 26.8years. Normal glucose tolerance (NGT) was found in 26.7%, while 18.3% had diabetes without impaired fasting glucose (CFRD without FPG). Mean BMI was 20.32, with a mean weight of 53.53kg; 32.8% had BMI<18.5, and only 4.7% were overweight. Overall, a positive relative change in weight (≥6%) was associated with an increase in FEV1% (9.31%), as compared to those with a greater weight loss (at least 2%), who had a 12.09% fall in FEV1. Patients with CFRD without FPG had poorer lung function if they had a negative relative change in weight by at least 2% as compared to NGT. In patients with CF, a relative weight gain is positively associated to FEV1%, while a relative weight loss of at least 2% has a significant negative impact on lung function. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  1. Influence of stapling the intersegmental planes on lung volume and function after segmentectomy.

    PubMed

    Tao, Hiroyuki; Tanaka, Toshiki; Hayashi, Tatsuro; Yoshida, Kumiko; Furukawa, Masashi; Yoshiyama, Koichi; Okabe, Kazunori

    2016-10-01

    Dividing the intersegmental planes with a stapler during pulmonary segmentectomy leads to volume loss in the remnant segment. The aim of this study was to assess the influence of segment division methods on preserved lung volume and pulmonary function after segmentectomy. Using image analysis software on computed tomography (CT) images of 41 patients, the ratio of remnant segment and ipsilateral lung volume to their preoperative values (R-seg and R-ips) was calculated. The ratio of postoperative actual forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) per those predicted values based on three-dimensional volumetry (R-FEV1 and R-FVC) was also calculated. Differences in actual/predicted ratios of lung volume and pulmonary function for each of the division methods were analysed. We also investigated the correlations of the actual/predicted ratio of remnant lung volume with that of postoperative pulmonary function. The intersegmental planes were divided by either electrocautery or with a stapler in 22 patients and with a stapler alone in 19 patients. Mean values of R-seg and R-ips were 82.7 (37.9-140.2) and 104.9 (77.5-129.2)%, respectively. The mean values of R-FEV1 and R-FVC were 103.9 (83.7-135.1) and 103.4 (82.2-125.1)%, respectively. There were no correlations between the actual/predicted ratio of remnant lung volume and pulmonary function based on the division method. Both R-FEV1 and R-FVC were correlated not with R-seg, but with R-ips. Stapling does not lead to less preserved volume or function than electrocautery in the division of the intersegmental planes. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. High-Resolution Time-Frequency Spectrum-Based Lung Function Test from a Smartphone Microphone

    PubMed Central

    Thap, Tharoeun; Chung, Heewon; Jeong, Changwon; Hwang, Ki-Eun; Kim, Hak-Ryul; Yoon, Kwon-Ha; Lee, Jinseok

    2016-01-01

    In this paper, a smartphone-based lung function test, developed to estimate lung function parameters using a high-resolution time-frequency spectrum from a smartphone built-in microphone is presented. A method of estimation of the forced expiratory volume in 1 s divided by forced vital capacity (FEV1/FVC) based on the variable frequency complex demodulation method (VFCDM) is first proposed. We evaluated our proposed method on 26 subjects, including 13 healthy subjects and 13 chronic obstructive pulmonary disease (COPD) patients, by comparing with the parameters clinically obtained from pulmonary function tests (PFTs). For the healthy subjects, we found that an absolute error (AE) and a root mean squared error (RMSE) of the FEV1/FVC ratio were 4.49% ± 3.38% and 5.54%, respectively. For the COPD patients, we found that AE and RMSE from COPD patients were 10.30% ± 10.59% and 14.48%, respectively. For both groups, we compared the results using the continuous wavelet transform (CWT) and short-time Fourier transform (STFT), and found that VFCDM was superior to CWT and STFT. Further, to estimate other parameters, including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and peak expiratory flow (PEF), regression analysis was conducted to establish a linear transformation. However, the parameters FVC, FEV1, and PEF had correlation factor r values of 0.323, 0.275, and −0.257, respectively, while FEV1/FVC had an r value of 0.814. The results obtained suggest that only the FEV1/FVC ratio can be accurately estimated from a smartphone built-in microphone. The other parameters, including FVC, FEV1, and PEF, were subjective and dependent on the subject’s familiarization with the test and performance of forced exhalation toward the microphone. PMID:27548164

  3. Decline in lung function related to exposure and selection processes among workers in the grain processing and animal feed industry.

    PubMed

    Post, W; Heederik, D; Houba, R

    1998-05-01

    To follow up workers in the grain processing and animal feed industry five years after an initial survey, and to monitor exposures to organic dust and endotoxin and changes in prevalence of respiratory symptoms and lung function. Outcome measures in the present survey were decline in lung function over five years, rapid annual decline in forced expiratory volume in one second (FEV1) above 90 ml.s-1, and loss to follow up. Among 140 workers included in the longitudinal analysis, annual decline in FEV1 and maximal mid-expiratory flow (MMEF) were significantly related to occupational exposure to dust and endotoxin in the grain processing and animal feed industry. Assuming a cumulative exposure over a working life of 40 years with an exposure of 5 mg.m-3, the estimated effect on the FEV1 would be a decline of 157 ml.s-1 (95% CI 13 to 300)--that is, about 4% of the group mean FEV1 and 473 ml.s-1 (95% CI 127 to 800) of the MMEF (about 12%). Workers with a dust exposure > 4 mg.m-3 or endotoxin concentrations > 20 ng.m-3 at the 1986-8 survey had significantly higher risk of rapid decline in FEV1 (odds ratio (OR) 3.3, 95% CI 1.02 to 10.3). The relations between occupational exposure and decline in lung function in this study occurred, despite the selection through the healthy worker effect that occurred as well. Increasing working years was related to decreasing annual decline in FEV1 and fewer people with rapid decline in FEV1 (OR 0.04, 95% CI 0 to 0.61 for over 20 v < 5 working years in the grain processing and animal feed industry). The presence of respiratory symptoms at baseline was a strong predictor of subsequent loss to follow up. Baseline lung function was not found to be predictive of subsequent loss to follow up. However, among workers lost to follow up the number of working years was more strongly negatively related to baseline lung function than among the workers who were studied longitudinally. The existence of the healthy worker effect implies that an exposure-response relation in the grain processing and animal feed industry may well be underestimated. This should be taken into account when health based recommended limit values are to be developed.

  4. Decline in lung function related to exposure and selection processes among workers in the grain processing and animal feed industry

    PubMed Central

    Post, W.; Heederik, D.; Houba, R.

    1998-01-01

    OBJECTIVES: To follow up workers in the grain processing and animal feed industry five years after an initial survey, and to monitor exposures to organic dust and endotoxin and changes in prevalence of respiratory symptoms and lung function. METHODS: Outcome measures in the present survey were decline in lung function over five years, rapid annual decline in forced expiratory volume in one second (FEV1) above 90 ml.s-1, and loss to follow up. RESULTS: Among 140 workers included in the longitudinal analysis, annual decline in FEV1 and maximal mid- expiratory flow (MMEF) were significantly related to occupational exposure to dust and endotoxin in the grain processing and animal feed industry. Assuming a cumulative exposure over a working life of 40 years with an exposure of 5 mg.m-3, the estimated effect on the FEV1 would be a decline of 157 ml.s-1 (95% CI 13 to 300)--that is, about 4% of the group mean FEV1 and 473 ml.s-1 (95% CI 127 to 800) of the MMEF (about 12%). Workers with a dust exposure > 4 mg.m-3 or endotoxin concentrations > 20 ng.m-3 at the 1986-8 survey had significantly higher risk of rapid decline in FEV1 (odds ratio (OR) 3.3, 95% CI 1.02 to 10.3). The relations between occupational exposure and decline in lung function in this study occurred, despite the selection through the healthy worker effect that occurred as well. Increasing working years was related to decreasing annual decline in FEV1 and fewer people with rapid decline in FEV1 (OR 0.04, 95% CI 0 to 0.61 for over 20 v < 5 working years in the grain processing and animal feed industry). The presence of respiratory symptoms at baseline was a strong predictor of subsequent loss to follow up. Baseline lung function was not found to be predictive of subsequent loss to follow up. However, among workers lost to follow up the number of working years was more strongly negatively related to baseline lung function than among the workers who were studied longitudinally. CONCLUSIONS: The existence of the healthy worker effect implies that an exposure-response relation in the grain processing and animal feed industry may well be underestimated. This should be taken into account when health based recommended limit values are to be developed.   PMID:9764113

  5. Probability of treatment following acute decline in lung function in children with cystic fibrosis is related to baseline pulmonary function.

    PubMed

    Morgan, Wayne J; Wagener, Jeffrey S; Yegin, Ashley; Pasta, David J; Millar, Stefanie J; Konstan, Michael W

    2013-10-01

    To determine whether the association between high forced expiratory volume in 1 second (FEV1) and increased rate of decline in FEV1 in children with cystic fibrosis could be due to less frequent intervention after acute declines (sudden decline events) in FEV1. Patients with cystic fibrosis aged 6-17 years enrolled in the Epidemiologic Study of Cystic Fibrosis were assessed for a sudden decline event, defined as a 10% relative decline in FEV1% predicted from an average of 3 consecutive stable baseline spirometries. The likelihood of therapeutic intervention within 14 days before and 56 days after this event was then related to their baseline FEV1% predicted age-specific decile using a logistic regression adjusting for age group (6-12 years, 13-17 years) and presence of Pseudomonas aeruginosa on respiratory culture. A total of 10 888 patients had at least 1 sudden decline event in FEV1. Patients in the highest FEV1 decile were significantly less likely than those in the lowest decile to receive intravenous antibiotics (OR, 0.14; 95% CI, 0.11-0.18; P < .001) or be hospitalized (OR, 0.18; 95% CI, 0.14-0.23; P < .001) following decline. Children and adolescents with high baseline lung function are less likely to receive a therapeutic intervention following an acute decline in FEV1, which may explain their greater rate of FEV1 decline. Copyright © 2013 Mosby, Inc. All rights reserved.

  6. Effect of Monthly, High-Dose, Long-Term Vitamin D on Lung Function: A Randomized Controlled Trial.

    PubMed

    Sluyter, John D; Camargo, Carlos A; Waayer, Debbie; Lawes, Carlene M M; Toop, Les; Khaw, Kay-Tee; Scragg, Robert

    2017-12-13

    Although observational studies suggest positive vitamin D-lung function associations, randomized trials are inconsistent. We examined effects of vitamin D supplementation on lung function. We recruited 442 adults (50-84 years, 58% male) into a randomized, double-blinded, placebo-controlled trial. Participants received, for 1.1 years (median; range = 0.9-1.5 years), either (1) vitamin D₃ 200,000 IU, followed by monthly 100,000 IU doses ( n = 226); or (2) placebo monthly ( n = 216). At baseline and follow-up, spirometry yielded forced expiratory volume in 1 s (FEV1; primary outcome). Mean (standard deviation) 25-hydroxyvitamin D increased from 61 (24) nmol/L at baseline to 119 (45) nmol/L at follow-up in the vitamin D group, but was unchanged in the placebo group. There were no significant lung function improvements (vitamin D versus placebo) in the total sample, vitamin D-deficient participants or asthma/chronic obstructive pulmonary disease (COPD) participants. However, among ever-smokers ( n = 217), the mean (95% confidence interval) FEV1 increase in the vitamin D versus placebo was 57 (4, 109) mL ( p = 0.03). FEV1 increases were larger among vitamin D-deficient ever-smokers ( n = 54): 122 (8, 236) mL ( p = 0.04). FEV1 improvements were largest among ever-smokers with asthma/COPD ( n = 60): 160 (53, 268) mL ( p = 0.004). Thus, vitamin D supplementation did not improve lung function among everyone, but benefited ever-smokers, especially those with vitamin D deficiency or asthma/COPD.

  7. Work-related respiratory symptoms and lung function among solderers in the electronics industry: a meta-analysis.

    PubMed

    Mendy, Angelico; Gasana, Janvier; Forno, Erick; Vieira, Edgar Ramos; Dowdye, Charissa

    2012-05-01

    Research on the respiratory effect of exposure to solder fumes in electronics workers has been conducted since the 1970s, but has yielded inconsistent results. The aim of this meta-analysis was to clarify the potential association. Effect sizes with corresponding 95% confidence intervals (CIs) for odds of respiratory symptoms related to soldering and spirometric parameters of solderers were extracted from seven studies and pooled to generate summary estimates and standardized mean differences in lung function measures between exposed persons and controls. Soldering was positively associated with wheeze after controlling for smoking (meta-odds ratio: 2.60, 95% CI: 1.46, 4.63) and with statistically significant reductions in forced expiratory volume in 1 s (FEV1) (-0.88%, 95% CI: -1.51, -0.26), forced vital capacity (FVC) (-0.64%, 95% CI: -1.18, -0.10), and FEV1/FVC (-0.35%, 95% CI: -0.65, -0.05). However, lung function parameters of solderers were within normal ranges [pooled mean FEV1: 97.85 (as percent of predicted), 95% CI: 94.70, 100.95, pooled mean FVC: 94.92 (as percent of predicted), 95% CI: 81.21, 108.64, and pooled mean FEV1/FVC: 86.5 (as percent), 95% CI: 78.01, 94.98]. Soldering may be a risk factor for wheeze, but may not be associated with a clinically significant impairment of lung function among electronics workers.

  8. Biomarkers of collagen turnover are related to annual change in FEV1 in patients with chronic obstructive pulmonary disease within the ECLIPSE study.

    PubMed

    Leeming, Diana J; Byrjalsen, Inger; Sand, Jannie M B; Bihlet, Asger R; Lange, Peter; Thal-Singer, Ruth; Miller, Bruce E; Karsdal, Morten A; Vestbo, Jørgen

    2017-12-04

    Change in forced expiratory volume in one second (FEV 1 ) is important for defining severity of chronic obstructive pulmonary disease (COPD). Serological neoepitope markers of collagen turnover may predict rate of change in FEV 1 . One thousand COPD subjects from the observational, multicentre, three-year ECLIPSE (Evaluation of COPD Longitudinally to Identify Predictive Surrogate Endpoints) study (NCT00292552, trial registration in February 2006) were included. Matrix metalloproteinase (MMP)-generated fragments of collagen type I, and type VI (C1M and C6M) were assessed in month six serum samples. A random-coefficient model with both a random intercept and a random slope was used to test the ability of the markers to predict post-dose bronchodilator FEV 1 (PD-FEV 1 ) change over two years adjusting for sex, age, BMI, smoking, bronchodilator reversibility, prior exacerbations, emphysema and chronic bronchitis status at baseline. Annual change of PD-FEV 1 was estimated from a linear model for the two-year study period. Serum C1M and C6M were independent predictors of lung function change (p = 0.007/0.005). Smoking, bronchodilator reversibility, plasma hsCRP and emphysema were also significant predictors. The effect estimate between annual change in PD-FEV 1 per one standard deviation (1SD) increase of C1M and C6M was +10.4 mL/yr. and +8.6 mL/yr. C1M, and C6M, had a significant association with baseline FEV 1 . We demonstrated that markers of tissue turnover were significantly associated with lung function change. These markers may function as prognostic biomarkers and possibly as efficacy biomarkers in clinical trials focusing on lung function change in COPD. NCT00292552 , Retrospectively registered, trial registration in February 2006.

  9. Impact of pulmonary rehabilitation on postoperative complications in patients with lung cancer and chronic obstructive pulmonary disease.

    PubMed

    Saito, Hajime; Hatakeyama, Kazutoshi; Konno, Hayato; Matsunaga, Toshiki; Shimada, Yoichi; Minamiya, Yoshihiro

    2017-09-01

    Given the extent of the surgical indications for pulmonary lobectomy in breathless patients, preoperative care and evaluation of pulmonary function are increasingly necessary. The aim of this study was to assess the contribution of preoperative pulmonary rehabilitation (PR) for reducing the incidence of postoperative pulmonary complications in non-small cell lung cancer (NSCLC) patients with chronic obstructive pulmonary disease (COPD). The records of 116 patients with COPD, including 51 patients who received PR, were retrospectively analyzed. Pulmonary function testing, including slow vital capacity (VC) and forced expiratory volume in one second (FEV 1 ), was obtained preoperatively, after PR, and at one and six months postoperatively. The recovery rate of postoperative pulmonary function was standardized for functional loss associated with the different resected lung volumes. Propensity score analysis generated matched pairs of 31 patients divided into PR and non-PR groups. The PR period was 18.7 ± 12.7 days in COPD patients. Preoperative pulmonary function was significantly improved after PR (VC 5.3%, FEV 1 5.5%; P < 0.05). The FEV 1 recovery rate one month after surgery was significantly better in the PR (101.6%; P < 0.001) than in the non-PR group (93.9%). In logistic regression analysis, predicted postoperative FEV 1 , predicted postoperative %FEV 1 , and PR were independent factors related to postoperative pulmonary complications after pulmonary lobectomy (odds ratio 18.9, 16.1, and 13.9, respectively; P < 0.05). PR improved the recovery rate of pulmonary function after lobectomy in the early period, and may decrease postoperative pulmonary complications. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  10. Native American ancestry, lung function, and COPD in Costa Ricans.

    PubMed

    Chen, Wei; Brehm, John M; Boutaoui, Nadia; Soto-Quiros, Manuel; Avila, Lydiana; Celli, Bartolome R; Bruse, Shannon; Tesfaigzi, Yohannes; Celedón, Juan C

    2014-04-01

    Whether Native American ancestry (NAA) is associated with COPD or lung function in a racially admixed Hispanic population is unknown. We recruited 578 Costa Ricans with and without COPD into a hybrid case-control/family-based cohort, including 316 members of families of index case subjects. All participants completed questionnaires and spirometry and gave a blood sample for DNA extraction. Genome-wide genotyping was conducted with the Illumina Human610-Quad and HumanOmniExpress BeadChip kits (Illumina Inc), and individual ancestral proportions were estimated from these genotypic data and reference panels. For unrelated individuals, linear or logistic regression was used for the analysis of NAA and COPD (GOLD [Global Initiative for Chronic Obstructive Lung Disease] stage II or greater) or lung function. For extended families, linear mixed models and generalized estimating equations were used for the analysis. All models were adjusted for age, sex, educational level, and smoking behavior; models for FEV1 were also adjusted for height. The average proportion of European, Native American, and African ancestry among participants was 62%, 35%, and 3%, respectively. After adjustment for current smoking and other covariates, NAA was inversely associated with COPD (OR per 10% increment, 0.55; 95% CI, 0.41-0.75) but positively associated with FEV1, FVC, and FEV1/FVC. After additional adjustment for pack-years of smoking, the association between NAA and COPD or lung function measures was slightly attenuated. We found that about 31% of the estimated effect of NAA on COPD is mediated by pack-years of smoking. NAA is inversely associated with COPD but positively associated with FEV1 or FVC in Costa Ricans. Ancestral effects on smoking behavior partly explain the findings for COPD but not for FEV1 or FVC.

  11. Native American Ancestry, Lung Function, and COPD in Costa Ricans

    PubMed Central

    Chen, Wei; Brehm, John M.; Boutaoui, Nadia; Soto-Quiros, Manuel; Avila, Lydiana; Celli, Bartolome R.; Bruse, Shannon; Tesfaigzi, Yohannes

    2014-01-01

    Background: Whether Native American ancestry (NAA) is associated with COPD or lung function in a racially admixed Hispanic population is unknown. Methods: We recruited 578 Costa Ricans with and without COPD into a hybrid case-control/family-based cohort, including 316 members of families of index case subjects. All participants completed questionnaires and spirometry and gave a blood sample for DNA extraction. Genome-wide genotyping was conducted with the Illumina Human610-Quad and HumanOmniExpress BeadChip kits (Illumina Inc), and individual ancestral proportions were estimated from these genotypic data and reference panels. For unrelated individuals, linear or logistic regression was used for the analysis of NAA and COPD (GOLD [Global Initiative for Chronic Obstructive Lung Disease] stage II or greater) or lung function. For extended families, linear mixed models and generalized estimating equations were used for the analysis. All models were adjusted for age, sex, educational level, and smoking behavior; models for FEV1 were also adjusted for height. Results: The average proportion of European, Native American, and African ancestry among participants was 62%, 35%, and 3%, respectively. After adjustment for current smoking and other covariates, NAA was inversely associated with COPD (OR per 10% increment, 0.55; 95% CI, 0.41-0.75) but positively associated with FEV1, FVC, and FEV1/FVC. After additional adjustment for pack-years of smoking, the association between NAA and COPD or lung function measures was slightly attenuated. We found that about 31% of the estimated effect of NAA on COPD is mediated by pack-years of smoking. Conclusions: NAA is inversely associated with COPD but positively associated with FEV1 or FVC in Costa Ricans. Ancestral effects on smoking behavior partly explain the findings for COPD but not for FEV1 or FVC. PMID:24306962

  12. The associations between weight-related anthropometrics during childhood and lung function in late childhood: a retrospective cohort study.

    PubMed

    Byberg, Kristine Kjer; Mikalsen, Ingvild Bruun; Eide, Geir Egil; Forman, Michele R; Júlíusson, Pétur Benedikt; Øymar, Knut

    2018-01-19

    An association between body weight in childhood and subsequent lung function and asthma has been suggested, but few longitudinal studies exist. Our aim was to explore whether weight-related anthropometric measurements through childhood were associated with lung function in late childhood. From an original nested case-control study, a cohort study was conducted, where lung function was measured in 463 children aged 12.8 years, and anthropometry was measured at several ages from birth through 12.8 years of age. Associations between anthropometrics and lung function were analysed using multiple linear and fractional polynomial regression analysis. Birthweight and body mass index (BMI; kg/m 2 ) at different ages through childhood were positively associated with forced vital capacity in percent of predicted (FVC %) and forced expiratory volume in the first second in percent of predicted (FEV 1 %) at 12.8 years of age. BMI, waist circumference, waist-to-height ratio and skinfolds at 12.8 years of age and the change in BMI from early to late childhood were positively associated with FVC % and FEV 1 % and negatively associated with FEV 1 /FVC and forced expiratory flow at 25-75% of FVC/FVC. Interaction analyses showed that positive associations between anthropometrics other than BMI and lung function were mainly found in girls. Inverse U-shaped associations were found between BMI at the ages of 10.8/11.8 (girls/boys) and 12.8 years (both genders) and FVC % and FEV 1 % at 12.8 years of age. Weight-related anthropometrics through childhood may influence lung function in late childhood. These findings may be physiological or associated with air flow limitation. Inverse U-shaped associations suggest a differential impact on lung function in normal-weight and overweight children. This study was observational without any health care intervention for the participants. Therefore, no trial registration number is available.

  13. Lung function impact from working in the pre-revolution Libyan quarry industry.

    PubMed

    Draid, Marwan M; Ben-Elhaj, Khaled M; Ali, Ashraf M; Schmid, Kendra K; Gibbs, Shawn G

    2015-05-07

    The purpose of this study was to determine the lung impact from working within the Libyan quarry industry, and if the length of work impacted the degree of degradation. Eighty three workers from eight silica quarries in the Nafusa Mountains of Libya opted to participate. These quarries were working the upper cretaceous geological structure. Eighty-five individuals who lived in Gharyan City with no affiliation to quarry operations participated as controls. Spirometry variables evaluated were Forced Vital Capacity (FVC), Forced Expiratory Volume at 1.0 second (FEV1), FVC/FEV1 and Peak Expiratory Flow (PEF). Control and exposed groups had no differences in terms of height, weight, or smoking status (p = 0.18, 0.20, 0.98, respectively). Prior to adjustment for other variables, FVC, FEV1, and PEF are all significantly lower in the exposed group (p = 0.003, 0.009, 0.03, respectively). After adjustment for age, height, weight, and smoking status, there remain significant differences between the control and exposed groups for FVC, FEV1, and PEF. This analysis demonstrated that exposure to quarry dust has a detrimental effect on lung function, and that pre-revolution Libyan quarry workers were being exposed. This study shows that any exposure is harmful, as the reduction in lung function was not significantly associated with years of exposure.

  14. PREOPERATIVE PREDICTION OF LUNG FUNCTION IN PNEUMONECTOMY BY SPIROMETRY AND LUNG PERFUSION SCINTIGRAPHY

    PubMed Central

    Cukic, Vesna

    2012-01-01

    Introduction: Nowadays an increasing number of lung resections are being done because of the rising prevalence of lung cancer that occurs mainly in patients with limited lung function, what is caused by common etiologic factor - smoking cigarettes. Loss of lung tissue in such patients can worsen much the postoperative pulmonary function. So it is necessary to asses the postoperative pulmonary function especially after maximal resection, i.e. pneumonectomy. Objective: To check over the accuracy of preoperative prognosis of postoperative lung function after pneumonectomy using spirometry and lung perfusion scinigraphy. Material and methods: The study was done on 17 patients operated at the Clinic for thoracic surgery, who were treated previously at the Clinic for Pulmonary Diseases “Podhrastovi” in the period from 01. 12. 2008. to 01. 06. 2011. Postoperative pulmonary function expressed as ppoFEV1 (predicted postoperative forced expiratory volume in one second) was prognosticated preoperatively using spirometry, i.e.. simple calculation according to the number of the pulmonary segments to be removed and perfusion lung scintigraphy. Results: There is no significant deviation of postoperative achieved values of FEV1 from predicted ones obtained by both methods, and there is no significant differences between predicted values (ppoFEV1) obtained by spirometry and perfusion scintigraphy. Conclusion: It is necessary to asses the postoperative pulmonary function before lung resection to avoid postoperative respiratory failure and other cardiopulmonary complications. It is absolutely necessary for pneumonectomy, i.e.. maximal pulmonary resection. It can be done with great possibility using spirometry or perfusion lung scintigraphy. PMID:23378687

  15. Reduced survival in adult cystic fibrosis despite attenuated lung function decline.

    PubMed

    Keating, Claire; Poor, Armeen D; Liu, Xinhua; Chiuzan, Codruta; Backenroth, Daniel; Zhang, Yuan; DiMango, Emily

    2017-01-01

    There is limited data on disease progression and survival in adult diagnosis cystic fibrosis (CF). This study evaluates change of lung function over time and rates of death/lung transplant in adult diagnosis CF. The CF Foundation Patient Registry was reviewed for patients diagnosed 1993-2003. Rate of FEV1 decline was calculated up to 2010 for age groups 6-11, 12-17, and 18 and above. Kaplan Meier method was used for 10 and 15year survival rate calculations for patients diagnosed as adults. Cox Proportional hazards models using predictors affecting disease progression and survival without transplant were run. Between 1993 and 2003, 11,884 patients were diagnosed with CF, of which 2848 were ages 6 and older. Annual rate of change of FEV1% predicted over 5years differed by diagnosis age group: -1.42% per year for ages 6-11, -2.04% for ages 12-17 and -1.13% for ages 18-65 (p<0.0001). Pseudomonas aeruginosa infection was associated with faster rates of lung function decline in all age groups. Survival without transplant for CF patients diagnosed at ≥18years were 76% and 65% by 10 and 15years, respectively. Of adults with FEV1 of >70% predicted at diagnosis, 95% were alive without transplant at 10years, whereas of those with FEV1<40% predicted at diagnosis, 31% were alive without transplant at 10years. Lung function declines at a slower rate in adult diagnosis CF. However, particularly in those with low lung function at diagnosis, rates of death or transplant in adult diagnosis CF after 10 and 15years is not negligible. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  16. Lung Cancer Risk Prediction Model Incorporating Lung Function: Development and Validation in the UK Biobank Prospective Cohort Study.

    PubMed

    Muller, David C; Johansson, Mattias; Brennan, Paul

    2017-03-10

    Purpose Several lung cancer risk prediction models have been developed, but none to date have assessed the predictive ability of lung function in a population-based cohort. We sought to develop and internally validate a model incorporating lung function using data from the UK Biobank prospective cohort study. Methods This analysis included 502,321 participants without a previous diagnosis of lung cancer, predominantly between 40 and 70 years of age. We used flexible parametric survival models to estimate the 2-year probability of lung cancer, accounting for the competing risk of death. Models included predictors previously shown to be associated with lung cancer risk, including sex, variables related to smoking history and nicotine addiction, medical history, family history of lung cancer, and lung function (forced expiratory volume in 1 second [FEV1]). Results During accumulated follow-up of 1,469,518 person-years, there were 738 lung cancer diagnoses. A model incorporating all predictors had excellent discrimination (concordance (c)-statistic [95% CI] = 0.85 [0.82 to 0.87]). Internal validation suggested that the model will discriminate well when applied to new data (optimism-corrected c-statistic = 0.84). The full model, including FEV1, also had modestly superior discriminatory power than one that was designed solely on the basis of questionnaire variables (c-statistic = 0.84 [0.82 to 0.86]; optimism-corrected c-statistic = 0.83; p FEV1 = 3.4 × 10 -13 ). The full model had better discrimination than standard lung cancer screening eligibility criteria (c-statistic = 0.66 [0.64 to 0.69]). Conclusion A risk prediction model that includes lung function has strong predictive ability, which could improve eligibility criteria for lung cancer screening programs.

  17. Correlation of 68Ga Ventilation-Perfusion PET/CT with Pulmonary Function Test Indices for Assessing Lung Function.

    PubMed

    Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S

    2015-11-01

    Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P < 0.05). FEV1/FVC and %NVQ had the highest correlation (r = 0.82). FEV1 was also best correlated with %NVQ (r = 0.64). DLCO was best correlated with the volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  18. Clinically important FEV1 declines among coal miners: an exploration of previously unrecognised determinants

    PubMed Central

    Wang, M. L.; Petsonk, E. L.; Beeckman, L. A.; Wagner, G. R.

    1999-01-01

    OBJECTIVES: The relation between occupational exposure to dust and loss of ventilatory lung function is now well established. However, many exposures during work and other activities might also have important roles in determining clinically important losses of lung function. In this study, we attempted to explore additional plausible determinants of exposures and other potential risk factors for clinically important decline in forced expiratory volume in 1 second (FEV1) during work in dusty trades. METHODS: The study was performed in 264 underground coal miners whose lung function had been followed up for an average of 11 years. With an extensive follow up questionnaire, miners were asked about their occupational and non-occupational exposures, smoking, personal and family medical history, and living conditions during childhood. RESULTS: Several variables of the mine environment (as well as previously recognised effects of mining work and region) were found to be associated with excess decline in FEV1, including work in roof bolting, exposure to explosive blasting, and to control dust spraying water that had been stored in holding tanks. Use of respiratory protection seemed to reduce the risk of decline in FEV1. Other factors that were found to be associated with declines in pulmonary function included smoking, body mass, weight gain, childhood pneumonia, and childhood exposure in the home to passive tobacco smoke and possibly smoke due to wood and coal fuels. Miners with excessive decline in FEV1 were less likely to be working in mining jobs at follow up. CONCLUSIONS: These findings suggest the existence of additional risk factors for decline in lung function in dusty trades, and may be useful in developing additional approaches to the prevention of chronic respiratory disease.   PMID:10658541

  19. Relationship between birth weight, maternal smoking during pregnancy and childhood and adolescent lung function: A path analysis.

    PubMed

    Balte, Pallavi; Karmaus, Wilfried; Roberts, Graham; Kurukulaaratchy, Ramesh; Mitchell, Frances; Arshad, Hasan

    2016-12-01

    Low birth weight and gestational maternal smoking have been linked with reduced lung function in children in many cross sectional studies. However, these associations have not yet been assessed with repeated measurements of lung function. Our aim was to investigate the effects of birth weight, gestational age, and gestational maternal smoking on lung function in children at age 10 and 18 years. In the Isle of Wight birth cohort spirometry was performed at age 10 and 18 years. Information on birth weight and gestational age were obtained from hospital records. Mothers were asked about smoking during pregnancy. We employed linear mixed models to estimate the effect of these risk factors on repeated measurements of lung function. We considered maternal asthma, sex, neonatal intensive care unit admission, height, socio-economic status, personal smoking in participants at age 18, body mass index and environmental tobacco smoke exposure as potential confounders. Finally, we used path analysis to determine links between birth weight, gestational age and gestational maternal smoking on lung function at age 10 and 18 years. Linear mixed models showed that with every 1 kg increase in birth weight, Forced expiratory volume in one second (FEV 1 ) increased by 42.6 ± 17.2 mL and Forced expiratory flow between 25% and 75% (FEF 25-75 ) of Forced vital capacity (FVC) increased by 95.5 ± 41.2 mL at age 18 years after adjusting for potential confounders. Path analysis suggested that birth weight had positive direct effects on FEV 1 and FEF 25-75 and positive indirect effect on FVC at 10 years which were carried forward to 18 years. Additionally, results also suggested a positive association between gestational age and FEV 1 , FVC and FEF 25-75  at ages 10 and 18 years and an inverse association between gestational smoke exposure and FEV 1 /FVC ratio and FEF 25-75  at age 18 years. Higher birth weight and gestational age were associated with higher FEV 1 , FVC and FEF 25-75 and maternal smoking during pregnancy was associated with reduced FEV 1 /FVC ratio and FEF 25-75 . The use of path analysis can improve our understanding of underlying "causal" pathways among different prenatal and childhood factors that affect lung function in both pre-adolescent and adolescent periods. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Does current reporting of lung function by the UK cystic fibrosis registry allow a fair comparison of adult centres?

    PubMed

    Nightingale, Julia Anne; Osmond, Clive

    2017-09-01

    Outcome data for UK cystic fibrosis centres are publicly available in an annual report, which ranks centres by median FEV 1 % predicted. We wished to assess whether there are differences in lung function outcomes between adult centres that might imply differing standards of care. UK Registry data from 4761 subjects at 34 anonymised adult centres were used to calculate mean FEV 1 % and rate of change of lung function for 2007-13. These measures were used to rank centres and compare outcomes. There are minor differences between centres for mean FEV 1 % for some years of the study and for rate of change of lung function over the study period. However, rankings are critically dependent on the outcome measure chosen and centre variation becomes negligible once patient population characteristics are taken into account. We have demonstrated that the ranking of centres is biased and any apparent difference in respiratory outcomes is unlikely to be related to differing standards of care between centres. Copyright © 2017 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  1. Air pollution and environmental risk factors for altered lung function among adult women of an urban slum area of Delhi: A prevalence study.

    PubMed

    Arora, Shweta; Rasania, S K; Bachani, D; Gandhi, Asha; Chhabra, S K

    2018-01-01

    Household and ambient air pollution are jointly responsible for about 7 million premature deaths annually. Women living in slums, with unhealthy environment, both indoors and outdoors, particularly those living close to industrial and/or vehicular pollution zones due to multiple sources of air pollution, are at the higher risk of having impaired lung function tests. The aim of this study was to estimate the prevalence of abnormal lung functions and to identify the environmental risk factors associated with them among adult women of 18-59 years. A total of 550 women aged 18-59 years were approached in a representative urban slum. Five hundred consented to participate and 299 had prebronchodilator spirometry satisfying ATS standards. House visits to assess environmental conditions were conducted to determine their association with forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC). Chi-square test was used to test the association of risk factors with lung functions. ANOVA was used to test the association of mean values of FEV1 and FVC with age. Out of 299 participants with acceptable spirometric curves, 5% had reduced FEV1/FVC ratio than the normal and 26.8% and 17.4% had lower values than predicted for FVC and FEV1, respectively. Altered lung function was related to age, tobacco smoking, and history of respiratory disease. Both ambient and household air pollution have a deleterious pulmonary effect on long-term women residents of a representative urban slum in Delhi.

  2. Air Pollution from Livestock Farms Is Associated with Airway Obstruction in Neighboring Residents.

    PubMed

    Borlée, Floor; Yzermans, C Joris; Aalders, Bernadette; Rooijackers, Jos; Krop, Esmeralda; Maassen, Catharina B M; Schellevis, François; Brunekreef, Bert; Heederik, Dick; Smit, Lidwien A M

    2017-11-01

    Livestock farm emissions may not only affect respiratory health of farmers but also of neighboring residents. To explore associations between spatial and temporal variation in pollutant emissions from livestock farms and lung function in a general, nonfarming, rural population in the Netherlands. We conducted a cross-sectional study in 2,308 adults (age, 20-72 yr). A pulmonary function test was performed measuring prebronchodilator and post-bronchodilator FEV 1 , FVC, FEV 1 /FVC, and maximum mid-expiratory flow (MMEF). Spatial exposure was assessed as (1) number of farms within 500 m and 1,000 m of the home, (2) distance to the nearest farm, and (3) modeled annual average fine dust emissions from farms within 500 m and 1,000 m of the home address. Temporal exposure was assessed as week-average ambient particulate matter <10 μm in diameter and ammonia (NH 3 ) concentrations before lung function measurements. Data were analyzed with generalized additive models (smoothing). A negative association was found between the number of livestock farms within a 1,000-m buffer from the home address and MMEF, which was more pronounced in participants without atopy. No associations were found with other spatial exposure variables. Week-average particulate matter <10 μm in diameter and NH 3 levels were negatively associated with FEV 1 , FEV 1 /FVC, and MMEF. In a two-pollutant model, only NH 3 remained associated. A 25-μg/m 3 increase in NH 3 was associated with a 2.22% lower FEV 1 (95% confidence interval, -3.69 to -0.74), FEV 1 /FVC of -1.12% (-1.96 to -0.28), and MMEF of -5.67% (-8.80 to -2.55). Spatial and temporal variation in livestock air pollution emissions are associated with lung function deficits in nonfarming residents.

  3. No mediating effects of glycemic control and inflammation on the association between vitamin D and lung function in the general population.

    PubMed

    Kaul, Anne; Gläser, Sven; Hannemann, Anke; Stubbe, Beate; Felix, Stefan B; Nauck, Matthias; Ewert, Ralf; Friedrich, Nele

    2017-04-01

    Vitamin D deficiency is discussed to be associated with lung health. While former studies focused on subjects suffering from pulmonary diseases, we aimed to investigate the association of 25-hydroxy vitamin D [25(OH)D] with lung function in the general population and examined whether mediating effects of inflammation, glycemic control or renal function exist. 1404 participants from the Study of Health in Pomerania with pulmonary function testing assessed by expiratory volume in 1 s (FEV 1 ), forced vital capacity (FVC), total lung capacity and Krogh index were used. Adjusted analysis of variance, linear regression models and mediation analyses were performed. Significant positive associations between 25(OH)D levels and FEV 1 , FVC and Krogh index were found. Mediator analyses revealed no mediating effect of inflammation (fibrinogen), glycemic control (HbA1c) or renal function (eGFR) on associations with FEV 1 or FVC. With respect to Krogh-Index, the association to 25(OH)D was slightly mediated by fibrinogen with a proportion mediated of 9.7%. Significant positive associations of 25(OH)D with lung function were revealed in a general population. The proposed mediating effects of inflammation, glycemic control and renal function on these relations were not confirmed. Further studies examining the causality of the association between 25(OH)D and lung function are necessary. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Lung function gain in preterm infants with and without bronchopulmonary dysplasia.

    PubMed

    Sanchez-Solis, Manuel; Perez-Fernandez, Virginia; Bosch-Gimenez, Vicente; Quesada, Juan J; Garcia-Marcos, Luis

    2016-09-01

    The aim of our study was to determine whether the development of lung function, during the first 2 years of life, is different in preterm infants who suffered or did not suffer from Bronchopulmonary dysplasia (BPD). We also assessed the role of nutritional status and growth in that development. Lung function tests were performed in 71 preterm infants at two time points: 6 months of corrected age and 1 year after. FVC, FEV0.5, FEF75 , and FEF25-75 were obtained from maximal expiratory volume curves by means of the raised volume rapid thoraco-abdominal compression technique. When comparing lung function measurements, we found that FVC (P = 0.033) FEV0.5 (P = 0.044), FEF75 (P = 0.014), and FEF25-75 (P = 0.036) were significantly lower in BPD infants. We did not find any catch-up of lung function during the study time, in neither the whole group of children nor within the BPD or non-BPD groups. The increase in lung function was directly proportional to the increase in weight and length. The multivariate analysis showed that the increase in z-score of FVC (P = 0.043), FEV0.5 (P = 0.015), and FEF75 (P = 0.042), was related with the height velocity during the study period. Infants who suffered from BPD have lower lung function (FVC, FEV0.5 , FEF75 , and FEF25-75 ), than those non-BPD, at two different time points 1 year apart. During the study period, there was no lung function catch-up in either BPD or non-BPD infants. The increase in length is closely associated to the increase in lung function. Pediatr Pulmonol. 2016; 51:936-942. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Machine Learning Algorithms Utilizing Quantitative CT Features May Predict Eventual Onset of Bronchiolitis Obliterans Syndrome After Lung Transplantation.

    PubMed

    Barbosa, Eduardo J Mortani; Lanclus, Maarten; Vos, Wim; Van Holsbeke, Cedric; De Backer, William; De Backer, Jan; Lee, James

    2018-02-19

    Long-term survival after lung transplantation (LTx) is limited by bronchiolitis obliterans syndrome (BOS), defined as a sustained decline in forced expiratory volume in the first second (FEV 1 ) not explained by other causes. We assessed whether machine learning (ML) utilizing quantitative computed tomography (qCT) metrics can predict eventual development of BOS. Paired inspiratory-expiratory CT scans of 71 patients who underwent LTx were analyzed retrospectively (BOS [n = 41] versus non-BOS [n = 30]), using at least two different time points. The BOS cohort experienced a reduction in FEV 1 of >10% compared to baseline FEV 1 post LTx. Multifactor analysis correlated declining FEV 1 with qCT features linked to acute inflammation or BOS onset. Student t test and ML were applied on baseline qCT features to identify lung transplant patients at baseline that eventually developed BOS. The FEV 1 decline in the BOS cohort correlated with an increase in the lung volume (P = .027) and in the central airway volume at functional residual capacity (P = .018), not observed in non-BOS patients, whereas the non-BOS cohort experienced a decrease in the central airway volume at total lung capacity with declining FEV 1 (P = .039). Twenty-three baseline qCT parameters could significantly distinguish between non-BOS patients and eventual BOS developers (P < .05), whereas no pulmonary function testing parameters could. Using ML methods (support vector machine), we could identify BOS developers at baseline with an accuracy of 85%, using only three qCT parameters. ML utilizing qCT could discern distinct mechanisms driving FEV 1 decline in BOS and non-BOS LTx patients and predict eventual onset of BOS. This approach may become useful to optimize management of LTx patients. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Endotoxin and gender modify lung function recovery after occupational organic dust exposure: a 30-year study.

    PubMed

    Lai, Peggy S; Hang, Jing-Qing; Valeri, Linda; Zhang, Feng-Ying; Zheng, Bu-Yong; Mehta, Amar J; Shi, Jing; Su, Li; Brown, Dan; Eisen, Ellen A; Christiani, David C

    2015-08-01

    The purpose of this study is to determine the trajectory of lung function change after exposure cessation to occupational organic dust exposure, and to identify factors that modify improvement. The Shanghai Textile Worker Study is a longitudinal study of 447 cotton workers exposed to endotoxin-containing dust and 472 silk workers exposed to non-endotoxin-containing dust. Spirometry was performed at 5-year intervals. Air sampling was performed to estimate individual cumulative exposures. The effect of work cessation on forced expiratory volume in 1 s (FEV1) was modelled using generalised additive mixed effects models to identify the trajectory of FEV1 recovery. Linear mixed effects models incorporating interaction terms were used to identify modifiers of FEV1 recovery. Loss to follow-up was accounted for with inverse probability of censoring weights. 74.2% of the original cohort still alive participated in 2011. Generalised additive mixed models identified a non-linear improvement in FEV1 for all workers after exposure cessation, with no plateau noted 25 years after retirement. Linear mixed effects models incorporating interaction terms identified prior endotoxin exposure (p=0.01) and male gender (p=0.002) as risk factors for impaired FEV1 improvement after exposure cessation. After adjusting for gender, smoking delayed the onset of FEV1 gain but did not affect the overall magnitude of change. Lung function improvement after cessation of exposure to organic dust is sustained. Endotoxin exposure and male gender are risk factors for less FEV1 improvement. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Lung Function before and after a Large Chlorine Gas Release in Graniteville, South Carolina

    PubMed Central

    Karmaus, Wilfried J. J.; Mohr, Lawrence C.; Cai, Bo; Balte, Pallavi; Gibson, James J.; Ownby, Dennis; Lawson, Andrew B.; Vena, John E.; Svendsen, Erik R.

    2016-01-01

    Rationale: On January 6, 2005 a train derailment led to an estimated 54,915-kg release of chlorine at a local textile mill in Graniteville, South Carolina. Objectives: We used the employee health spirometry records of the textile to identify enduring effects of chlorine gas exposure resulting from the incident on the lung function of workers employed at the textile mill. Methods: Spirometry records from 1,807 mill workers (7,332 observations) were used from 4 years before and 18 months after the disaster. Longitudinal analysis using marginal regression models produced annual population mean estimates for FEV1, FVC, and FEV1/FVC ratio. Covariate adjustment was made for sex, age, smoking, height, season tested, technician, obesity, season × year interactions, and smoker × year interactions. The increased prevalence of mill workers having accelerated FEV1 decline was also evaluated after the chlorine spill. Measurements and Main Results: In the year of the accident, we observed a significant reduction in mean FEV1 (–4.2% predicted; P = 0.019) when compared with the year before the incident. In the second year, partial recovery in the mean FVC % predicted level was seen, but the cohort’s average FEV1/FVC ratio continued to decrease over time. Severe annual FEV1 decline was most prevalent in the year of the accident, and independent of mill worker smoking status. Conclusions: The Graniteville mill worker cohort revealed significant reductions in lung function immediately after the chlorine incident. Improvement was seen in the second year; but the proportion of mill workers experiencing accelerated FEV1 annual decline significantly increased in the 18 months after the chlorine incident. PMID:26695511

  8. Patterns of Growth and Decline in Lung Function in Persistent Childhood Asthma.

    PubMed

    McGeachie, M J; Yates, K P; Zhou, X; Guo, F; Sternberg, A L; Van Natta, M L; Wise, R A; Szefler, S J; Sharma, S; Kho, A T; Cho, M H; Croteau-Chonka, D C; Castaldi, P J; Jain, G; Sanyal, A; Zhan, Y; Lajoie, B R; Dekker, J; Stamatoyannopoulos, J; Covar, R A; Zeiger, R S; Adkinson, N F; Williams, P V; Kelly, H W; Grasemann, H; Vonk, J M; Koppelman, G H; Postma, D S; Raby, B A; Houston, I; Lu, Q; Fuhlbrigge, A L; Tantisira, K G; Silverman, E K; Tonascia, J; Weiss, S T; Strunk, R C

    2016-05-12

    Tracking longitudinal measurements of growth and decline in lung function in patients with persistent childhood asthma may reveal links between asthma and subsequent chronic airflow obstruction. We classified children with asthma according to four characteristic patterns of lung-function growth and decline on the basis of graphs showing forced expiratory volume in 1 second (FEV1), representing spirometric measurements performed from childhood into adulthood. Risk factors associated with abnormal patterns were also examined. To define normal values, we used FEV1 values from participants in the National Health and Nutrition Examination Survey who did not have asthma. Of the 684 study participants, 170 (25%) had a normal pattern of lung-function growth without early decline, and 514 (75%) had abnormal patterns: 176 (26%) had reduced growth and an early decline, 160 (23%) had reduced growth only, and 178 (26%) had normal growth and an early decline. Lower baseline values for FEV1, smaller bronchodilator response, airway hyperresponsiveness at baseline, and male sex were associated with reduced growth (P<0.001 for all comparisons). At the last spirometric measurement (mean [±SD] age, 26.0±1.8 years), 73 participants (11%) met Global Initiative for Chronic Obstructive Lung Disease spirometric criteria for lung-function impairment that was consistent with chronic obstructive pulmonary disease (COPD); these participants were more likely to have a reduced pattern of growth than a normal pattern (18% vs. 3%, P<0.001). Childhood impairment of lung function and male sex were the most significant predictors of abnormal longitudinal patterns of lung-function growth and decline. Children with persistent asthma and reduced growth of lung function are at increased risk for fixed airflow obstruction and possibly COPD in early adulthood. (Funded by the Parker B. Francis Foundation and others; ClinicalTrials.gov number, NCT00000575.).

  9. Effects of Exposure to Welding Fume on Lung Function: Results from the German WELDOX Study.

    PubMed

    Lehnert, M; Hoffmeyer, F; Gawrych, K; Lotz, A; Heinze, E; Berresheim, H; Merget, R; Harth, V; Van Gelder, R; Hahn, J-U; Hartwig, A; Weiß, T; Pesch, B; Brüning, T

    2015-01-01

    The association between exposure to welding fume and chronic obstructive pulmonary disease (COPD) has been insufficiently clarified. In this study we assessed the influence of exposure to welding fume on lung function parameters. We investigated forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and expiratory flow rates in 219 welders. We measured current exposure to respirable particles and estimated a worker's lifetime exposure considering welding techniques, working conditions and protective measures at current and former workplaces. Multiple regression models were applied to estimate the influence of exposure to welding fume, age, and smoking on lung function. We additionally investigated the duration of working as a welder and the predominant welding technique. The findings were that age- and smoking-adjusted lung function parameters showed no decline with increasing duration, current exposure level, and lifetime exposure to welding fume. However, 15% of the welders had FEV1/FVC below the lower limit of normal, but we could not substantiate the presence of an association with the measures of exposure. Adverse effects of cigarette smoking were confirmed. In conclusion, the study did not support the notion of a possible detrimental effect of exposure to welding fume on lung function in welders.

  10. Beyond lung function in COPD management: effectiveness of LABA/LAMA combination therapy on patient-centred outcomes.

    PubMed

    van der Molen, Thys; Cazzola, Mario

    2012-03-01

    Bronchodilators are central to the management of chronic obstructive pulmonary disease (COPD). Clinical studies combining different classes of bronchodilators, in particular a long-acting muscarinic antagonist (LAMA) and a long-acting β2-agonist (LABA), have demonstrated greater improvements in lung function (forced expiratory volume in 1 second, FEV1) in patients with COPD than monotherapy. FEV1 has served as an important diagnostic measurement of COPD, and the majority of clinical studies of currently available pharmacotherapies grade effectiveness of treatment regimens based on improvements in FEV1. However, FEV1 alone may not adequately reflect the overall health status of the patient. Published evidence suggests that LABA/LAMA combination therapies demonstrate greater improvements in patient-centred outcomes such as dyspnoea, symptoms, rescue medication use, and quality of life than individual drugs used alone. Evaluating patient-centred outcomes associated with COPD is likely to play an important role in future research as a measure of overall treatment effectiveness. Raising awareness of the importance of outcomes beyond lung function alone, particularly in primary care where most patients initially present themselves for medical evaluation, should form a fundamental part of a more holistic approach to COPD management.

  11. Blood Leukocyte Concentrations, FEV1 Decline, and Airflow Limitation. A 15-Year Longitudinal Study of World Trade Center-exposed Firefighters.

    PubMed

    Zeig-Owens, Rachel; Singh, Ankura; Aldrich, Thomas K; Hall, Charles B; Schwartz, Theresa; Webber, Mayris P; Cohen, Hillel W; Kelly, Kerry J; Nolan, Anna; Prezant, David J; Weiden, Michael D

    2018-02-01

    Rescue/recovery work at the World Trade Center disaster site (WTC) caused a proximate decline in lung function in Fire Department of the City of New York firefighters. A subset of this cohort experienced an accelerated rate of lung function decline over 15 years of post-September 11, 2001 (9/11) follow-up. To determine if early postexposure blood leukocyte concentrations are biomarkers for subsequent FEV 1 decline and incident airflow limitation. Individual rates of forced expiratory volume in 1 second (FEV 1 ) change were calculated for 9,434 firefighters using 88,709 spirometric measurements taken between September 11, 2001, and September 10, 2016. We categorized FEV 1 change rates into three trajectories: accelerated FEV 1 decline (FEV 1 loss >64 ml/yr), expected FEV 1 decline (FEV 1 loss between 0 and 64 ml/yr), and improved FEV 1 (positive rate of change >0 ml/yr). Occurrence of FEV 1 /FVC less than 0.70 after 9/11 defined incident airflow limitation. Using regression models, we assessed associations of post-9/11 blood eosinophil and neutrophil concentrations with subsequent FEV 1 decline and airflow limitation, adjusted for age, race, smoking, height, WTC exposure level, weight change, and baseline lung function. Accelerated FEV 1 decline occurred in 12.7% of participants (1,199 of 9,434), whereas post-9/11 FEV 1 improvement occurred in 8.3% (780 of 9,434). Higher blood eosinophil and neutrophil concentrations were each associated with accelerated FEV 1 decline after adjustment for covariates (odds ratio [OR], 1.10 per 100 eosinophils/μl; 95% confidence interval [CI], 1.05-1.15; and OR, 1.10 per 1,000 neutrophils/μl; 95% CI, 1.05-1.15, respectively). Multivariable-adjusted linear regression models showed that a higher blood neutrophil concentration was associated with a faster rate of FEV 1 decline (1.14 ml/yr decline per 1,000 neutrophils/μl; 95% CI, 0.69-1.60 ml/yr; P < 0.001). Higher blood eosinophil concentrations were associated with a faster rate of FEV 1 decline in ever-smokers (1.46 ml/yr decline per 100 eosinophils/μl; 95% CI, 0.65-2.26 ml/yr; P < 0.001) but not in never-smokers (P for interaction = 0.004). Higher eosinophil concentrations were also associated with incident airflow limitation (adjusted hazard ratio, 1.10 per 100 eosinophils/μl; 95% CI, 1.04-1.15). Compared with the expected FEV 1 decline group, individuals experiencing accelerated FEV 1 decline were more likely to have incident airflow limitation (adjusted OR, 4.12; 95% CI, 3.30-5.14). Higher post-9/11 blood neutrophil and eosinophil concentrations were associated with subsequent accelerated FEV 1 decline in WTC-exposed firefighters. Both higher blood eosinophil concentrations and accelerated FEV 1 decline were associated with incident airflow limitation in WTC-exposed firefighters.

  12. Efficacy and safety of lumacaftor/ivacaftor combination therapy in patients with cystic fibrosis homozygous for Phe508del CFTR by pulmonary function subgroup: a pooled analysis.

    PubMed

    Elborn, J Stuart; Ramsey, Bonnie W; Boyle, Michael P; Konstan, Michael W; Huang, Xiaohong; Marigowda, Gautham; Waltz, David; Wainwright, Claire E

    2016-08-01

    Lumacaftor/ivacaftor combination therapy has shown clinical benefits in patients with cystic fibrosis homozygous for the Phe508del CFTR mutation; however, pretreatment lung function is a confounding factor that potentially affects the efficacy and safety of this therapy. We aimed to assess the efficacy and safety of lumacaftor/ivacaftor therapy in these patients, defined by specific categories of lung function. Both trials (TRAFFIC and TRANSPORT) included in this pooled analysis were multinational, randomised, double-blind, placebo-controlled, parallel-group, phase 3 studies. Eligible patients from 187 participating centres in North America, Australia, and the European Union (both trials) were aged 12 years or older with a confirmed diagnosis of cystic fibrosis, homozygous for the Phe508del CFTR mutation, and with a percent predicted FEV1 (ppFEV1) of 40-90 at the time of screening. Patients were randomly assigned with an interactive web response system (1:1:1) to receive placebo, lumacaftor (600 mg once daily) plus ivacaftor (250 mg every 12 h), or lumacaftor (400 mg every 12 h) plus ivacaftor (250 mg every 12 h) for 24 weeks. Prespecified subgroup analyses of pooled efficacy and safety data by lung function, as measured by ppFEV1, were done for patients with baseline ppFEV1 (<40 and ≥40) and screening ppFEV1 (<70 and ≥70). The primary endpoint was the absolute change from baseline in ppFEV1 at week 24 analysed in all randomised patients who received at least one dose of study drug. Both trials are registered with ClinicalTrials.gov (TRAFFIC: NCT01807923; TRANSPORT: NCT01807949). Both trials were done between April, 2013, and April, 2014. Of the 1108 patients included in the efficacy analysis, 81 patients had a ppFEV1 that decreased to lower than 40 between screening and baseline and 1016 had a ppFEV1 of 40 or higher at baseline. At screening, 730 had a ppFEV1 of less than 70, and 342 had a ppFEV1 of 70 or higher. Improvements in the absolute change from baseline at week 24 in ppFEV1 were observed with both lumacaftor/ivacaftor doses in the subgroup with baseline ppFEV1 levels lower than 40 (least-squares mean difference vs placebo was 3·7 percentage points [95% CI 0·5-6·9; p=0·024] in the lumacaftor [600 mg/day]-ivacaftor group and 3·3 percentage points [0·2-6·4; p=0·036] in the lumacaftor [400 mg/12 h]-ivacaftor group). Improvements in ppFEV1 compared with placebo were also reported in the subgroup with baseline ppFEV1 levels of 40 or higher (3·3 percentage points [2·3-4·4; p<0·0001] in the lumacaftor [600 mg per day]-ivacaftor group and 2·8 percentage points [1·7-3·8; p<0·0001] in the lumacaftor [400 mg/12 h]-ivacaftor group). Similar absolute improvements in ppFEV1 compared with placebo were observed in subgroups with screening ppFEV1 levels lower than 70 and ppFEV1 levels of 70 or higher. Increases in body-mass index and reduction in number of pulmonary exacerbation events were observed in both lumacaftor/ivacaftor dose groups compared with placebo across all lung function subgroups. Treatment was generally well tolerated, although the incidence of some respiratory adverse events was higher with lumacaftor/ivacaftor than with placebo in all subgroups. In patients with baseline ppFEV1 levels lower than 40, these adverse events included cough, dyspnoea, and abnormal respiration. These analyses confirm that lumacaftor/ivacaftor combination therapy benefits patients with cystic fibrosis homozygous for Phe508del CFTR who have varying degrees of lung function impairment. Vertex Pharmaceuticals. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Lung function among 9- to 10-year-old Tibetan and Han Chinese schoolchildren living at different altitudes in Tibet.

    PubMed

    Yangzong; Berntsen, Sveinung; Bjertness, Espen; Stigum, Hein; Gonggalanzi; Bianba; Nafstad, Per

    2013-03-01

    Tibetans have lived at high altitude longer than any other high-altitude population. Still little is known about their lung function and especially among children. This study compared lung function values of forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and forced expiratory flow at 50% of FVC (FEF50) in children living at various altitudes in Tibet and with different ancestries. A cross-sectional study of lung function was performed among 9-10-year-old native Tibetan and Han Chinese children living at 3700 meters above sea level, and among native Tibetan children living at 4300 meters above sea level. The adjusted FVC and FEV1 were significantly higher in Tibetan children living at 4300 m above sea level as compared to Tibetans living at 3700 m. Tibetans living at 3700 m had higher FVC and FEV1 than Han Chinese living at the same altitude. All Tibetan children had on average higher FEF50 than Han Chinese. Tibetan children living at an altitude of 4300 m had relatively higher lung function than those living at 3700 m, and there were differences in lung function between Tibetans and Han Chinese who live at the same altitude. It seems likely that genetic factors involved in long-term adaptation to high altitude and cultural attributes could have contributed to the study findings.

  14. Lung function reductions associated with motor vehicle density in chronic obstructive pulmonary disease: a cross-sectional study.

    PubMed

    Nitschke, Monika; Appleton, Sarah L; Li, Qiaoyu; Tucker, Graeme R; Shah, Pushan; Bi, Peng; Pisaniello, Dino L; Adams, Robert J

    2016-10-24

    Motor vehicle-related air pollution can potentially impair lung function. The effect of pollution in people with compromised pulmonary function such as in COPD has not been previously investigated. To examine the association of lung function with motor vehicle density in people with spirometrically determined COPD in a cross-sectional study. In 2004-06, The North West Adelaide Health Study (NWAHS), a biomedical cohort of adults assessed pre and post-bronchodilator spirometry (n = 3,103). Traffic density, obtained from the motor vehicle inventory maintained by the South Australian Environment Protection Authority, was expressed as the daily numbers of vehicles travelling within a 200 m diameter zone around participants' geocoded residences. In subjects with COPD (FEV 1 /FVC <0.7, n = 221, 7.1 %), increasing daily vehicle density was associated with statistically significant decreases in lung function parameters after adjustment for smoking and socio-economic variables. Mean (95 % CI) post-bronchodilator % predicted FEV 1 was 81 % (76-87) in the low (≤7179/day) compared with 71 % (67-75) in the high (≥15,270/day) vehicle exposure group (p < 0.05). Linear regression analysis in all subjects with COPD showed significant decrements in post-bronchodilator FEV 1 /FVC ratio and % predicted FEV 1 of 0.03 and 0.05 % respectively per daily increase in 1000 vehicles. In men with COPD (n = 150), the corresponding reductions were 0.03 and 0.06 %. Smaller, non-significant decrements were seen in females. No difference was seen in those without COPD. Vehicle traffic density was associated with significant reductions in lung function in people with COPD. Urban planning should consider the health impacts for those with pre-existing respiratory conditions.

  15. Assessing exposure risk for dust storm events-associated lung function decrement in asthmatics and implications for control

    NASA Astrophysics Data System (ADS)

    Hsieh, Nan-Hung; Liao, Chung-Min

    2013-04-01

    Asian dust storms (ADS) events are seasonally-based meteorological phenomena that exacerbate chronic respiratory diseases. The purpose of this study was to assess human health risk from airborne dust exposure during ADS events in Taiwan. A probabilistic risk assessment framework was developed based on exposure and experimental data to quantify ADS events induced lung function decrement. The study reanalyzed experimental data from aerosol challenge in asthmatic individuals to construct the dose-response relationship between inhaled dust aerosol dose and decreasing percentage of forced expiratory volume in 1 s (%FEV1). An empirical lung deposition model was used to predict deposition fraction for size specific dust aerosols in pulmonary regions. The toxicokinetic and toxicodynamic models were used to simulate dust aerosols binding kinetics in lung airway in that %FEV1 change was also predicted. The mask respirators were applied to control the inhaled dose under dust aerosols exposure. Our results found that only 2% probability the mild ADS events were likely to cause %FEV1 decrement higher than 5%. There were 50% probability of decreasing %FEV1 exceeding 16.9, 18.9, and 7.1% in north, center, and south Taiwan under severe ADS events, respectively. Our result implicates that the use of activated carbon of mask respirators has the best efficacy for reducing inhaled dust aerosol dose, by which the %FEV1 decrement can be reduced up to less than 1%.

  16. Cleaning at Home and at Work in Relation to Lung Function Decline and Airway Obstruction.

    PubMed

    Svanes, Øistein; Bertelsen, Randi J; Lygre, Stein H L; Carsin, Anne E; Antó, Josep M; Forsberg, Bertil; García-García, José M; Gullón, José A; Heinrich, Joachim; Holm, Mathias; Kogevinas, Manolis; Urrutia, Isabel; Leynaert, Bénédicte; Moratalla, Jesús M; Le Moual, Nicole; Lytras, Theodore; Norbäck, Dan; Nowak, Dennis; Olivieri, Mario; Pin, Isabelle; Probst-Hensch, Nicole; Schlünssen, Vivi; Sigsgaard, Torben; Skorge, Trude D; Villani, Simona; Jarvis, Debbie; Zock, Jan P; Svanes, Cecilie

    2018-05-01

    Cleaning tasks may imply exposure to chemical agents with potential harmful effects to the respiratory system, and increased risk of asthma and respiratory symptoms among professional cleaners and in persons cleaning at home has been reported. Long-term consequences of cleaning agents on respiratory health are, however, not well described. This study aimed to investigate long-term effects of occupational cleaning and cleaning at home on lung function decline and airway obstruction. The European Community Respiratory Health Survey (ECRHS) investigated a multicenter population-based cohort at three time points over 20 years. A total of 6,235 participants with at least one lung function measurement from 22 study centers, who in ECRHS II responded to questionnaire modules concerning cleaning activities between ECRHS I and ECRHS II, were included. The data were analyzed with mixed linear models adjusting for potential confounders. As compared with women not engaged in cleaning (ΔFEV 1  = -18.5 ml/yr), FEV 1 declined more rapidly in women responsible for cleaning at home (-22.1; P = 0.01) and occupational cleaners (-22.4; P = 0.03). The same was found for decline in FVC (ΔFVC = -8.8 ml/yr; -13.1, P = 0.02; and -15.9, P = 0.002; respectively). Both cleaning sprays and other cleaning agents were associated with accelerated FEV 1 decline (-22.0, P = 0.04; and -22.9, P = 0.004; respectively). Cleaning was not significantly associated with lung function decline in men or with FEV 1 /FVC decline or airway obstruction. Women cleaning at home or working as occupational cleaners had accelerated decline in lung function, suggesting that exposures related to cleaning activities may constitute a risk to long-term respiratory health.

  17. Lung Function Impact from Working in the Pre-Revolution Libyan Quarry Industry

    PubMed Central

    Draid, Marwan M.; Ben-Elhaj, Khaled M.; Ali, Ashraf M.; Schmid, Kendra K.; Gibbs, Shawn G.

    2015-01-01

    The purpose of this study was to determine the lung impact from working within the Libyan quarry industry, and if the length of work impacted the degree of degradation. Eighty three workers from eight silica quarries in the Nafusa Mountains of Libya opted to participate. These quarries were working the upper cretaceous geological structure. Eighty-five individuals who lived in Gharyan City with no affiliation to quarry operations participated as controls. Spirometry variables evaluated were Forced Vital Capacity (FVC), Forced Expiratory Volume at 1.0 second (FEV1), FVC/FEV1 and Peak Expiratory Flow (PEF). Control and exposed groups had no differences in terms of height, weight, or smoking status (p = 0.18, 0.20, 0.98, respectively). Prior to adjustment for other variables, FVC, FEV1, and PEF are all significantly lower in the exposed group (p = 0.003, 0.009, 0.03, respectively). After adjustment for age, height, weight, and smoking status, there remain significant differences between the control and exposed groups for FVC, FEV1, and PEF. This analysis demonstrated that exposure to quarry dust has a detrimental effect on lung function, and that pre-revolution Libyan quarry workers were being exposed. This study shows that any exposure is harmful, as the reduction in lung function was not significantly associated with years of exposure. PMID:25961801

  18. Ventilatory function in rubber processing workers: acute changes over the workshift.

    PubMed

    Governa, M; Comai, M; Valentino, M; Antonicelli, L; Rinaldi, F; Pisani, E

    1987-02-01

    When considering rubber tyre manufacturing from an occupational health viewpoint, three areas may be identified in which exposure to respirable materials are potentially harmful: the processing, curing, and talc areas. A study of the ventilatory function of the entire work force employed in the processing area in a rubber tyre manufacturing plant was undertaken to determine whether an acute reduction in lung function occurs over the course of their working shift (the plant worked a three shift system) and whether a chronic exposure to the occupational airborne contaminants causes permanent changes in lung function. The ventilatory function was measured at the worksite at the beginning and immediately after the end of the workshift. No evidence of chronic obstructive pulmonary disease was found and in most cases no significant decline in FEV1 was observed. Only one of the 79 individuals showed a moderate obstruction, measured by the ratio FEV1/FVC which gave the value of 0.55, with no variation over the shift. For non-smokers, the FVC, FEV1, and FEF25-75% were lower in those exposed for more than five years than in those exposed for five years or less. A similar pattern was also observed in the FVC and FEV1 of the smokers. None of these differences was statistically significant. Within each exposure group the pulmonary function of the smokers was lower than that of the non-smokers, but the only significant difference was found in the values of FEF25-75%. Only one man showed a decline in the FEV1/FVC ratio over the shift, but during each shift, a decrease in all the lung function tests was observed. The decrease was smallest during the first of the three shifts. These results are thought to support the hypothesis that there are acute adverse effects over an eight hour shift. Further investigations are needed to discover whether these acute changes in lung function result from a chemical stimulation or irritant receptors in the airways.

  19. Acute effects of summer air pollution on respiratory function in primary school children in southern England.

    PubMed Central

    Scarlett, J F; Abbott, K J; Peacock, J L; Strachan, D P; Anderson, H R

    1996-01-01

    BACKGROUND: There is growing concern about health effects of air pollution in the UK. Studies in the USA have reported adverse effects on lung function among children but no comparable studies have been published in the UK. This study investigates the relationship between daily changes in ambient air pollution and short term variations in lung function in a panel of school children. METHODS: One hundred and fifty four children aged 7-11 attending a primary school adjacent to a major motorway in Surrey, south-east England, were studied. Bellows spirometry was performed daily on 31 schooldays between 6 June and 21 July 1994. Levels of ozone, nitrogen dioxide, and particulates of less than 10 microns in diameter (PM10) were measured continuously at the school and the pollen count was measured six miles away. Relationships between daily changes in forced expiratory volume in 0.75 seconds (FEV0.75), forced vital capacity (FVC), the FEV0.75/FVC ratio and pollutants were analysed using separate autoregressive models for each child. A weighted average of the resulting slopes was then calculated. RESULTS: There was a significant inverse relationship between daily mean PM10 levels lagged one day and FVC, with a reduction in lung function of 1% (95% CI 0.3% to 2%) across the whole range of PM10 levels (20-150 micrograms/m3). The effect on FEV0.75 was similar (-0.5%) but was not significant when weighted by 1/SE2 (95% CI -1.2% to 0.2%). There was no effect of PM10 levels on the FEV0.75/FVC ratio. No significant association was seen between FEV0.75, FVC, or the FEV0.75/FVC ratio and either ozone or nitrogen dioxide levels. There was no evidence that wheezy children were more affected than healthy children. Pollen levels on the previous day had no effect on lung function and did not change the air pollution results. CONCLUSIONS: There is a very small, but statistically significant, adverse effect of airborne respirable particulate matter, measured as PM10, on lung function in this study group. There is no evidence for an inverse association of lung function with levels of ozone or NO2 measured on the previous day. PMID:8958894

  20. Relationship of Antibiotic Treatment to Recovery after Acute FEV1 Decline in Children with Cystic Fibrosis.

    PubMed

    Morgan, Wayne J; Wagener, Jeffrey S; Pasta, David J; Millar, Stefanie J; VanDevanter, Donald R; Konstan, Michael W

    2017-06-01

    Children with cystic fibrosis often experience acute declines in lung function. We previously showed that such declines are not always treated with antibiotics, but we did not assess whether treatment improves the likelihood of recovery. To determine whether new antibiotic treatment was associated with recovery from acute FEV 1 decline. We studied episodes of FEV 1 decline (≥10% from baseline) in the Epidemiologic Study of Cystic Fibrosis. Treatments were hospitalization, home intravenous antibiotic, new inhaled oral quinolone, or other oral antibiotic. We used logistic regression to evaluate whether treatment was associated with recovery to baseline or near baseline. Logistic regression of 9,875 patients showed that new antibiotic treatment was associated with an increased likelihood of recovery to 90% of baseline (P < 0.001), especially for hospitalization compared with no new antibiotic (odds ratio [OR], 2.79; 95% confidence interval, 2.41-3.23). All four outpatient treatments were associated with greater likelihood of recovery compared with no treatment (OR, 1.27-1.64). Inpatient treatment was better than outpatient treatment (OR, 1.94; 95% confidence interval, 1.68-2.23). Treatment-type ORs were similar across recovery criteria and levels of baseline lung function. New antibiotic therapy, and especially inpatient treatment, is associated with greater likelihood of recovery after acute decline in FEV 1 . Benefits extend across all disease stages and are especially important in patients with high lung function, who are at greatest risk for FEV 1 decline.

  1. Genetic regulation of gene expression in the lung identifies CST3 and CD22 as potential causal genes for airflow obstruction.

    PubMed

    Lamontagne, Maxime; Timens, Wim; Hao, Ke; Bossé, Yohan; Laviolette, Michel; Steiling, Katrina; Campbell, Joshua D; Couture, Christian; Conti, Massimo; Sherwood, Karen; Hogg, James C; Brandsma, Corry-Anke; van den Berge, Maarten; Sandford, Andrew; Lam, Stephen; Lenburg, Marc E; Spira, Avrum; Paré, Peter D; Nickle, David; Sin, Don D; Postma, Dirkje S

    2014-11-01

    COPD is a complex chronic disease with poorly understood pathogenesis. Integrative genomic approaches have the potential to elucidate the biological networks underlying COPD and lung function. We recently combined genome-wide genotyping and gene expression in 1111 human lung specimens to map expression quantitative trait loci (eQTL). To determine causal associations between COPD and lung function-associated single nucleotide polymorphisms (SNPs) and lung tissue gene expression changes in our lung eQTL dataset. We evaluated causality between SNPs and gene expression for three COPD phenotypes: FEV(1)% predicted, FEV(1)/FVC and COPD as a categorical variable. Different models were assessed in the three cohorts independently and in a meta-analysis. SNPs associated with a COPD phenotype and gene expression were subjected to causal pathway modelling and manual curation. In silico analyses evaluated functional enrichment of biological pathways among newly identified causal genes. Biologically relevant causal genes were validated in two separate gene expression datasets of lung tissues and bronchial airway brushings. High reliability causal relations were found in SNP-mRNA-phenotype triplets for FEV(1)% predicted (n=169) and FEV(1)/FVC (n=80). Several genes of potential biological relevance for COPD were revealed. eQTL-SNPs upregulating cystatin C (CST3) and CD22 were associated with worse lung function. Signalling pathways enriched with causal genes included xenobiotic metabolism, apoptosis, protease-antiprotease and oxidant-antioxidant balance. By using integrative genomics and analysing the relationships of COPD phenotypes with SNPs and gene expression in lung tissue, we identified CST3 and CD22 as potential causal genes for airflow obstruction. This study also augmented the understanding of previously described COPD pathways. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Effects of antenatal multiple micronutrient supplementation on lung function in mid-childhood: follow-up of a double-blind randomised controlled trial in Nepal

    PubMed Central

    Devakumar, D; Stocks, J; Ayres, JG; Kirkby, J; Yadav, SK; Saville, NM; Devereux, G; Wells, JCK; Manandhar, DS; Costello, A; Osrin, D

    2015-01-01

    A randomised trial of prenatal multiple micronutrient supplementation in Nepalese women increased birthweight and weight at two years of age in offspring, compared with those born to mothers who only received iron and folic acid supplements. Further follow-up of this cohort provided an opportunity to investigate the effect of antenatal multiple micronutrients on subsequent lung function, by measuring spirometry at 7-9 years of age in children born in the trial. 841 children (80% of the cohort) were seen at mean (SD) 8.5 (0.4) years. Technically successful spirometry results were obtained in 793 children (94.3%), 50% of whom had been randomised to micronutrient supplementation. Background characteristics, including anthropometry, were similar in the two allocation groups. Lung function was also similar, mean (95%CI) difference in z-scores (supplementation – control) being −0.08 (−0.19, 0.04) for FEV1; −0.05 (−0.17, 0.06) for FVC and −0.04 (−0.15, 0.07) for FEV1/FVC. Compared with healthy White children, FEV1 and FVC in the ‘healthy’ Nepalese children were ~1 z-score (~13%) lower, with no difference in FEV1/FVC. We conclude that, compared with routine iron and folic acid, multiple micronutrient supplementation during pregnancy has no effect on spirometric lung function in Nepalese children at 8.5 years of age. PMID:25700386

  3. [The dose response decrease of lung function associated with the urinary polycyclic aromatic hydrocarbons metabolites in coke oven workers].

    PubMed

    Hu, Die; Deng, Qi-fei; Huang, Su-li; He, Yun-feng; Guo, Huan; Wu, Tang-chun

    2012-12-01

    To analyze the relationship between metabolites of polycyclic aromatic hydrocarbons (PAHs) and lung function in coke oven workers, and to provide scientific basis for further exploring the potential mechanism and developing the preventing strategies of the workers' early lung damage. We measured carbon monoxide, sulfur dioxide, benzene soluble matter, particulate matters, and PAHs at different workplaces of a coke oven plant. Detailed information on demography and occupational health condition of 912 workers were collected. We divided these workers into control group and coke oven group according to their workplaces and the different concentrations of COEs in the environment. We detected 10 urinary PAH metabolites and lung function using gas chromatography-mass spectrometry and spirometric tests, respectively. FEV(1.0) (91.12 ± 13.31) and FEV(1.0)/FVC (108.61 ± 20.37) of the coke oven group is significantly lower than the control group (94.16 ± 15.57, 113.45 ± 19.70). In the coke oven group, the hydroxyphenanthrene and 1-hydroxypyrene are negatively correlated with FEV(1.0)/FVC (β = -0.136, β = -0.100), Ptrend < 0.05 for all. The dose response decrease of lung function is associated with the urinary PAH metabolites in coke oven workers. Indicated that the long exposure to PAHs may cause the early lung damage in coke oven workers, phenanthrene and pyrene may be the main factors.

  4. Early detection of lung function decrements in children and adolescents with cystic fibrosis using new reference values.

    PubMed

    Zacharasiewicz, Angela; Renner, Sabine; Haderer, Flora; Weber, Michael; Dehlink, Eleonore; Szepfalusi, Zsolt; Frischer, Thomas

    2017-08-01

    Interpretation of lung function values in children with cystic fibrosis (CF) depends on the applied reference values. We hypothesize that differences between the new global lung function initiative (GLI) values and the formerly used Zapletal et al. values produce significantly different clinical results. We analyzed 3719 lung function measurements of 108 children and adolescents (n = 54 male; aged 6-18 years) with CF treated between September 1991 and July 2009. Data were analyzed in milliliters (ml) and % predicted (pred.) and interpreted using Zapletal and GLI reference values. Applying GLI compared to Zapletal resulted in significantly lower mean forced expiratory volume in 1s (FEV1)% pred. Zapletal 86.6% (SD 20.6), GLI 79.9% (SD 20.3) and 32% (n = 497/1543) were misclassified as normal when using Zapletal. Despite showing no overall differences in FEV1 and forced vital capacity (FVC) between concomitant Pseudomonas detection (PA+) in n = 938 and Pseudomonas negative (PA-) (n = 2781) using either reference PA+ resulted in lower FEV1 and FVC values with increasing age; however, measurement of small airway obstruction with forced expiratory flow at 75% of FVC (FEF75) values - available for Zapletal -showed significant differences. Reassurance regarding lung function when using old reference values may occur with potential clinical significance. Discrepancies in lung function interpretation underline the importance of using uniform and best available reference values.

  5. LONG TERM EFFECTS OF PRENATAL AND POSTNATAL AIRBORNE PAH EXPOSURE ON VENTILATORY LUNG FUNCTION OF NON-ASTHMATIC PREADOLESCENT CHILDREN. PROSPECTIVE BIRTH COHORT STUDY IN KRAKOW

    PubMed Central

    Jedrychowski, Wieslaw A.; Perera, Frederica P.; Maugeri, Umberto; Majewska, Renata; Mroz, Elzbieta; Flak, Elzbieta; Camman, David; Sowa, Agata; Jacek, Ryszard

    2014-01-01

    The main goal of the study was to test the hypothesis that prenatal and postnatal exposure to polycyclic aromatic hydrocarbons (PAH) is associated with depressed lung function in non-asthmatic children. The study sample comprises 195 non-asthmatic children of non-smoking mothers, among whom the prenatal PAH exposure was assessed by personal air monitoring in pregnancy. At the age of 3, residential air monitoring was carried out to evaluate the residential PAH exposure indoors and outdoors. At the age of 5 to 8, children were given allergic skin tests for indoor allergens; and between 5–9 years lung function testing (FVC, FEV05, FEV1 and FEF25–75) was performed. The effects of prenatal PAH exposure on lung function tests repeated over the follow-up were adjusted in the General Estimated Equation (GEE) model for the relevant covariates. No association between FVC with prenatal PAH exposure was found; however for the FEV1 deficit associated with higher prenatal PAH exposure (above 37ng/m3) amounted to 53 mL (p = 0.050) and the deficit of FEF25–75 reached 164 mL (p=0.013). The corresponding deficits related to postnatal residential indoor PAH level (above 42 ng/m3) were 59 mL of FEV1 (p=0.028) and 140 mL of FEF25–75 (p=0.031). At the higher residential outdoor PAH level (above 90 ng/m3) slightly greater deficit of FEV1 (71mL, p = 0.009) was observed. The results of the study suggest that transplacental exposure to PAH compromises the normal developmental process of respiratory airways and that this effect is compounded by postnatal PAH exposure. PMID:25300014

  6. Multiple Antibiotic–Resistant Pseudomonas aeruginosa and Lung Function Decline in Patients with Cystic Fibrosis

    PubMed Central

    Ren, Clement L; Konstan, Michael W.; Yegin, Ashley; Rasouliyan, Lawrence; Trzaskoma, Benjamin; Morgan, Wayne J.; Regelmann, Warren

    2014-01-01

    Background The goal of this study was to determine the association of multiple antibiotic– resistant Pseudomonas aeruginosa (MARPA) acquisition with lung function decline in patients with cystic fibrosis (CF). Methods Using data from Epidemiologic Study of Cystic Fibrosis (ESCF), we identified patients with spirometry data and MARPA, defined as PA (1) resistant to gentamicin and either tobramycin or amikacin and (2) resistant to ≥1 antipseudomonal beta lactam. MARPA had to be detected in a respiratory culture after ≥ 2 years of PA-positive but MARPA-negative respiratory cultures. Multivariable piecewise linear regression was performed to model the annual rate of decline in forced expiratory volume in 1 second (FEV1) % predicted 2 calendar years before and after the index year of MARPA detection, adjusting for patient characteristics and CF therapies. Results In total, 4,349 patients with chronic PA and adequate PFT data were identified; 1,111 subsequently developed MARPA, while 3,238 patients were PA positive but MARPA negative. Compared with patients who did not acquire MARPA, MARPA-positive patients had lower FEV1 and received more oral (p<0.013) and inhaled p<0.001) antibiotic therapy. Mean FEV1 decline did not change significantly after MARPA detection (−2.22 % predicted/year before detection and −2.43 after, p=0.45). There was no relationship between persistent infection or FEV1 quartile and FEV1 decline. Conclusions Newly detected MARPA was not associated with a significant change in the rate of FEV1 decline. These results suggest that MARPA is more likely to be a marker of more severe disease and more intensive therapy, and less likely to be contributing independently to more rapid lung function decline. PMID:22445849

  7. Lung Mass in Smokers

    PubMed Central

    Washko, George R.; Kinney, Gregory L.; Ross, James C.; San José Estépar, Raúl; Han, MeiLan K.; Dransfield, Mark T.; Kim, Victor; Hatabu, Hiroto; Come, Carolyn E.; Bowler, Russell P.; Silverman, Edwin K.; Crapo, James; Lynch, David A.; Hokanson, John; Diaz, Alejandro A.

    2017-01-01

    Rationale and Objective Emphysema is characterized by airspace dilation, inflammation, and irregular deposition of elastin and collagen in the interstitium. Computed tomographic (CT) studies have reported that lung mass (LM) may be increased in smokers, a finding attributed to inflammatory and parenchymal remodeling processes observed on histopathology. We sought to examine the epidemiologic and clinical associations of LM in smokers. Materials and Methods Baseline epidemiologic, clinical, and CT data (n=8,156) from smokers enrolled into the COPDGene Study were analyzed. LM was calculated from the CT scan. Changes in lung function at five-year follow-up were available from 1,623 subjects. Regression analysis was performed to assess for associations of LM with forced expiratory volume in 1 second (FEV1) and FEV1 decline. Results Subjects with Global Initiative for Chronic Obstructive Lung Disease (GOLD) 1 COPD had greater LM than either smokers with normal lung function or those with GOLD 2–4 COPD (P<0.001 for both comparisons). LM was predictive of rate of the decline in FEV1 (decline per 100 g, −4.7 ± 1.7 ml/yr, P=0.006). Conclusion Our cross sectional data suggest the presence of a biphasic radiologic remodeling process in smokers: the presence of such non-linearity must be accounted for in longitudinal CT studies. Baseline LM predicts the decline in lung function. PMID:27940230

  8. Lung function in insulation workers.

    PubMed Central

    Clausen, J; Netterstrøm, B; Wolff, C

    1993-01-01

    To evaluate the effects of working with modern insulation materials (rock and glass wool), the members of the Copenhagen Union of Insulation Workers were invited to participate in a study based on a health examination that included lung function tests. Three hundred and forty men (74%) agreed to participate, and 166 bus drivers served as the control group. Age distribution, height, and smoking habits were similar in the two groups. Forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) were used as tests for lung function. There were no differences in FVC between the study and control groups, but the insulation workers had significantly lower values of FEV1 (mean 2.51) compared with the controls (mean 3.4 1), independent of smoking habits. Six years before the present study, 114 of the insulation workers participated in a similar study, and eight years after the initial study, the lung function of 59 of the bus drivers was tested. The decline in FVC in insulation workers who smoked was significantly higher (7.7 cl/year) than in bus drivers who smoked (3.1 cl/year); the decline in FEV1 was significantly higher in insulation workers independent of smoking habits (17.0 cl/year v 2.9 cl/year). Self assessed former exposure to asbestos was not associated with lung function in insulation workers. The study concludes that working with modern insulation materials is associated with increased risk of developing obstructive lung disease. PMID:8457492

  9. Respiratory function in healthy ever-smokers is impaired by smoking habits in a dose-dependent manner.

    PubMed

    Osanai, Shinobu; Ogasa, Toshiyuki; Sumitomo, Kazuhiro; Hasebe, Naoyuki

    2018-01-01

    There is limited information about the respiratory function of ever-smokers without lung disorders. We sought to assess the effects of smoking habits on respiratory function in subjects without lung disorders. Subjects were recruited from among patients without any evidence of respiratory disorders who visited rural primary care clinics. Each participant was asked to answer a questionnaire that included questions smoking history. Their forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) were measured. We analyzed 802 subjects (364 men and 438 women). The means of the lambda-mu-sigma method derived z-score of FEV1 (zFEV1) both in current-smokers and ex-smokers were lower than that in never-smokers. The mean zFEV1 in the ever-smokers with more than 30 pack-years of smoking history were lower than that in the ever-smokers with less smoking history. Univariate analysis showed that there were significant negative correlations between pack-years and zFEV1 both in the ex-smokers and current-smokers. There was no significant correlation between the duration of smoking cessation and zFEV1 in the ex-smokers. Our data suggests that respiratory function in healthy ever-smokers is decreased based on smoking habits in a dose-dependent manner. Even after a long period of smoking cessation, the decreased respiratory function seems to be maintained in ex-smokers. Copyright © 2017 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  10. Early fundoplication is associated with slower decline in lung function after lung transplantation in patients with gastroesophageal reflux disease.

    PubMed

    Biswas Roy, Sreeja; Elnahas, Shaimaa; Serrone, Rosemarie; Haworth, Cassandra; Olson, Michael T; Kang, Paul; Smith, Michael A; Bremner, Ross M; Huang, Jasmine L

    2018-06-01

    Gastroesophageal reflux disease (GERD) is prevalent after lung transplantation. Fundoplication slows lung function decline in patients with GERD, but the optimal timing of fundoplication is unknown. We retrospectively reviewed patients who underwent fundoplication after lung transplantion at our center from April 2007 to July 2014. Patients were divided into 2 groups: early fundoplication (<6 months after lung transplantation) and late fundoplication (≥6 months after lung transplantation). Annual decline in percent predicted forced expiratory volume in 1 second (FEV 1 ) was analyzed. Of the 251 patients who underwent lung transplantation during the study period with available pH data, 86 (34.3%) underwent post-transplantation fundoplication for GERD. Thirty of 86 (34.9%) had early fundoplication and 56 of 86 (65.1%) had late fundoplication. Median time from lung transplantation to fundoplication was 4.6 months (interquartile range, 2.0-5.2) and 13.8 months (interquartile range, 9.0-16.1) for the early and late groups, respectively. The median DeMeester score was comparable between groups. One-, 3-, and 5-year actuarial survival rates in the early group were 90%, 70%, and 70%, respectively; in the late group, these rates were 91%, 66%, and 66% (log rank P = .60). Three- and 5-year percent predicted FEV 1 was lower in the late group by 8.9% (95% confidence interval, -30.2 to 12.38; P = .46) and 40.7% (95% confidence interval, -73.66 to -7.69; P = .019). A linear mixed model showed a 5.7% lower percent predicted FEV 1 over time in the late fundoplication group (P < .001). In this study, patients with early fundoplication had a higher FEV 1 5 years after lung transplantation. Early fundoplication might protect against GERD-induced lung damage in lung transplant recipients with GERD. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  11. Childhood-Onset Asthma in Smokers. Association between CT Measures of Airway Size, Lung Function, and Chronic Airflow Obstruction

    PubMed Central

    Hardin, Megan E.; Come, Carolyn E.; San José Estépar, Raúl; Ross, James C.; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K.; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K.; Crapo, James D.; Lynch, David A.; Make, Barry; Barr, R. Graham; Hersh, Craig P.; Washko, George R.

    2014-01-01

    Rationale and Objectives: Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. Methods: We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Measurements and Main Results: Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. Conclusion: In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764). PMID:25296268

  12. Childhood-onset asthma in smokers. association between CT measures of airway size, lung function, and chronic airflow obstruction.

    PubMed

    Diaz, Alejandro A; Hardin, Megan E; Come, Carolyn E; San José Estépar, Raúl; Ross, James C; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K; Crapo, James D; Lynch, David A; Make, Barry; Barr, R Graham; Hersh, Craig P; Washko, George R

    2014-11-01

    Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764).

  13. Association between arachidonate 5-lipoxygenase-activating protein (ALOX5AP) and lung function in a Korean population.

    PubMed

    Ro, M; Kim, S; Pyun, J-A; Shin, C; Cho, N H; Lee, J-Y; Koh, I; Kwack, K

    2012-08-01

    Arachidonate 5-lipoxygenase-activating protein (ALOX5AP) plays a role in the 5-lipoxygenase (LO) pathway, which includes the LTC(4), LTD(4), LTE(4) and LTB(4). These leukotrienes are known causative factors of asthma, allergy, atopy and cardiovascular diseases. ALOX5AP lacks enzyme activity and acts by helping 5-LO function. In this study, healthy and general subjects who live in rural and urban areas of Korea were tested for the association of ALOX5AP polymorphisms with lung function. Lung function was also estimated by calculating the predicted values for forced expiratory volume in one second (FEV(1) _%PRED) and the proportion of the forced vital capacity exhaled in the first second (FEV(1) /FVC_PRED). The linear regression was adjusted for residence area, gender, age, height and smoking status. The analysis revealed associations between FEV(1) and the single-nucleotide polymorphism (SNP) rs9506352 and the haplotype TCAC (permuted P-value < 0.05). The linkage disequilibrium block that included the significant SNPs overlapped with SNPs that were revealed previously to associate with myocardial infarction and asthma and to affect lung function. This study is the first to demonstrate the association between lung function and ALOX5AP polymorphisms in a healthy and general population. © 2012 The Authors. Scandinavian Journal of Immunology © 2012 Blackwell Publishing Ltd.

  14. Joint Effects of Smoking and Sedentary Lifestyle on Lung Function in African Americans: The Jackson Heart Study Cohort

    PubMed Central

    Campbell Jenkins, Brenda W.; Sarpong, Daniel F.; Addison, Clifton; White, Monique S.; Hickson, DeMarc A.; White, Wendy; Burchfiel, Cecil

    2014-01-01

    This study examined: (a) differences in lung function between current and non current smokers who had sedentary lifestyles and non sedentary lifestyles and (b) the mediating effect of sedentary lifestyle on the association between smoking and lung function in African Americans. Sedentary lifestyle was defined as the lowest quartile of the total physical activity score. The results of linear and logistic regression analyses revealed that non smokers with non sedentary lifestyles had the highest level of lung function, and smokers with sedentary lifestyles had the lowest level. The female non-smokers with sedentary lifestyles had a significantly higher FEV1% predicted and FVC% predicted than smokers with non sedentary lifestyles (93.3% vs. 88.6%; p = 0.0102 and 92.1% vs. 86.9%; p = 0.0055 respectively). FEV1/FVC ratio for men was higher in non smokers with sedentary lifestyles than in smokers with non sedentary lifestyles (80.9 vs. 78.1; p = 0.0048). Though smoking is inversely associated with lung function, it seems to have a more deleterious effect than sedentary lifestyle on lung function. Physically active smokers had higher lung function than their non physically active counterparts. PMID:24477212

  15. Joint effects of smoking and sedentary lifestyle on lung function in African Americans: the Jackson Heart Study cohort.

    PubMed

    Campbell Jenkins, Brenda W; Sarpong, Daniel F; Addison, Clifton; White, Monique S; Hickson, Demarc A; White, Wendy; Burchfiel, Cecil

    2014-01-28

    This study examined: (a) differences in lung function between current and non current smokers who had sedentary lifestyles and non sedentary lifestyles and (b) the mediating effect of sedentary lifestyle on the association between smoking and lung function in African Americans. Sedentary lifestyle was defined as the lowest quartile of the total physical activity score. The results of linear and logistic regression analyses revealed that non smokers with non sedentary lifestyles had the highest level of lung function, and smokers with sedentary lifestyles had the lowest level. The female non-smokers with sedentary lifestyles had a significantly higher FEV1% predicted and FVC% predicted than smokers with non sedentary lifestyles (93.3% vs. 88.6%; p = 0.0102 and 92.1% vs. 86.9%; p = 0.0055 respectively). FEV1/FVC ratio for men was higher in non smokers with sedentary lifestyles than in smokers with non sedentary lifestyles (80.9 vs. 78.1; p = 0.0048). Though smoking is inversely associated with lung function, it seems to have a more deleterious effect than sedentary lifestyle on lung function. Physically active smokers had higher lung function than their non physically active counterparts.

  16. Effect of gender specific anthropometric characteristics on lung function in young competitive triathletes from Malaysia.

    PubMed

    Johari, Hanapi M; Zainudin, Hakimi A; Knight, Victor F; Lumley, Steven A; Subramanium, Ananthan S; Caszo, Brinnell A; Gnanou, Justin V

    2017-04-01

    Anthropometric and lung function characteristics of triathletes are important for the implementation of individual specific training and recovery recommendations. However, limited data are available for these parameters in triathletes. Hence, the aim of this study was to characterize and examine the gender differences of lung function and anthropometry parameters in competitive triathletes from Malaysia. Body composition assessment and lung function tests were performed on sixteen competitive triathletes (nine male and seven female). The subject's body composition profile including muscle mass (kg), fat free mass (kg), and percent body fat was measured using a bio-impedance segmental body composition analyzer. Forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) were measured by Quark PFT2 spirometer. The anthropometric measurements revealed that male triathletes were significantly taller than female triathletes and had significantly more protein and skeletal muscle mass. The female triathletes, however, had significantly higher percent body fat. Male triathletes had statistically significant higher FVC and FEV1 than female triathletes. Both the male and female triathletes showed a positive correlation between height, fat free mass and the lung function markers FVC and FEV1. This association was not seen with Body Mass Index (BMI) in female triathletes. The data from our study shows that anthropometric parameters are directly linked to lung function of a triathlete. We also found the relationship between BMI and lung function to be gender specific in triathletes and is dependent on the body protein and fat content. Hence, body composition characterization is essential and provides valuable information for developing individual specific training modules.

  17. Association of blood eosinophils and plasma periostin with FEV1 response after 3-month inhaled corticosteroid and long-acting beta2-agonist treatment in stable COPD patients

    PubMed Central

    Park, Hye Yun; Lee, Hyun; Koh, Won-Jung; Kim, Seonwoo; Jeong, Ina; Koo, Hyeon-Kyoung; Kim, Tae-Hyung; Kim, Jin Woo; Kim, Woo Jin; Oh, Yeon-Mok; Sin, Don D; Lim, Seong Yong; Lee, Sang-Do

    2016-01-01

    Background COPD patients with increased airway eosinophilic inflammation show a favorable response to inhaled corticosteroids (ICS) in combination with a long-acting bronchodilator. Recent studies have demonstrated a significant correlation of sputum eosinophilia with blood eosinophils and periostin. We investigated whether high blood eosinophils and plasma periostin were associated with an improvement in forced expiratory volume in 1 second (FEV1) after 3-month treatment with ICS/long-acting beta2-agonist (LABA) in stable COPD patients. Patients and methods Blood eosinophils and plasma periostin levels were measured in 130 stable COPD subjects selected from the Korean Obstructive Lung Disease cohort. Subjects began a 3-month ICS/LABA treatment after washout period. Results High blood eosinophils (>260/µL, adjusted odds ratio =3.52, P=0.009) and high plasma periostin (>23 ng/mL, adjusted odds ratio =3.52, P=0.013) were significantly associated with FEV1 responders (>12% and 200 mL increase in FEV1 from baseline after treatment). Moreover, the addition of high blood eosinophils to age, baseline positive bronchodilator response, and FEV1 <50% of the predicted value significantly increased the area under the curve for prediction of FEV1 responders (from 0.700 to 0.771; P=0.045). Conclusion High blood eosinophils and high plasma periostin were associated with improved lung function after 3-month ICS/LABA treatment. In particular, high blood eosinophils, in combination with age and baseline lung function parameters, might be a possible biomarker for identification of COPD patients with favorable FEV1 improvement in response to ICS/LABA treatment. PMID:26730185

  18. Association of blood eosinophils and plasma periostin with FEV1 response after 3-month inhaled corticosteroid and long-acting beta2-agonist treatment in stable COPD patients.

    PubMed

    Park, Hye Yun; Lee, Hyun; Koh, Won-Jung; Kim, Seonwoo; Jeong, Ina; Koo, Hyeon-Kyoung; Kim, Tae-Hyung; Kim, Jin Woo; Kim, Woo Jin; Oh, Yeon-Mok; Sin, Don D; Lim, Seong Yong; Lee, Sang-Do

    2016-01-01

    COPD patients with increased airway eosinophilic inflammation show a favorable response to inhaled corticosteroids (ICS) in combination with a long-acting bronchodilator. Recent studies have demonstrated a significant correlation of sputum eosinophilia with blood eosinophils and periostin. We investigated whether high blood eosinophils and plasma periostin were associated with an improvement in forced expiratory volume in 1 second (FEV1) after 3-month treatment with ICS/long-acting beta2-agonist (LABA) in stable COPD patients. Blood eosinophils and plasma periostin levels were measured in 130 stable COPD subjects selected from the Korean Obstructive Lung Disease cohort. Subjects began a 3-month ICS/LABA treatment after washout period. High blood eosinophils (>260/µL, adjusted odds ratio =3.52, P=0.009) and high plasma periostin (>23 ng/mL, adjusted odds ratio =3.52, P=0.013) were significantly associated with FEV1 responders (>12% and 200 mL increase in FEV1 from baseline after treatment). Moreover, the addition of high blood eosinophils to age, baseline positive bronchodilator response, and FEV1 <50% of the predicted value significantly increased the area under the curve for prediction of FEV1 responders (from 0.700 to 0.771; P=0.045). High blood eosinophils and high plasma periostin were associated with improved lung function after 3-month ICS/LABA treatment. In particular, high blood eosinophils, in combination with age and baseline lung function parameters, might be a possible biomarker for identification of COPD patients with favorable FEV1 improvement in response to ICS/LABA treatment.

  19. Pulmonary function tests in the preoperative evaluation of lung cancer surgery candidates. A review of guidelines.

    PubMed

    Trzaska-Sobczak, Marzena; Skoczyński, Szymon; Pierzchała, Władysław

    2014-09-01

    Before planned surgical treatment of lung cancer, the patient's respiratory system function should be evaluated. According to the current guidelines, the assessment should start with measurements of FEV1 (forced expiratory volume in 1 second) and DLco (carbon monoxide lung diffusion capacity). Pneumonectomy is possible when FEV1 and DLco are > 80% of the predicted value (p.v.). If either of these parameters is < 80%, an exercise test with VO2 max (oxygen consumption during maximal exercise) measurement should be performed. When VO2 max is < 35 % p.v. or < 10 ml/kg/min, resection is associated with high risk. If VO2 max is in the range of 35-75% p.v. or 10-20 ml/kg/min, the postoperative values of FEV1 and DLco (ppoFEV1, ppoDLco) should be determined. The exercise test with VO2 max measurement may be replaced with other tests such as the shuttle walk test and the stair climbing test. The distance covered during the shuttle walk test should be > 400 m. Patients considered for lobectomy should be able to climb 3 flights of stairs (12 m) and for pneumonectomy 5 flights of stairs (22 m).

  20. Impact of exacerbations on respiratory system impedance measured by a forced oscillation technique in COPD: a prospective observational study.

    PubMed

    Kamada, Takahiro; Kaneko, Masahiro; Tomioka, Hiromi

    2017-01-01

    Forced oscillation technique (FOT) has been reported to be useful in the evaluation and management of obstructive lung disease, including COPD. To date, no data are available concerning long-term changes in respiratory system impedance measured by FOT. Additionally, although exacerbations have been reported to be associated with excessive lung function decline in COPD, the impact of exacerbations on the results of FOT has not been demonstrated. The aim of this study was to investigate the longitudinal changes in respiratory system impedance and the influence of exacerbations thereon. Between March 2011 and March 2012, outpatients who attended Kobe City Medical Center West Hospital with a diagnosis of COPD were assessed for eligibility. Baseline patient characteristics (age, sex, body mass index, smoking history, current smoking status, COPD stage), lung function (post-bronchodilator forced expiratory volume in 1 second [FEV 1 ]), blood tests (neutrophils and eosinophils), FOT, and COPD assessment test results were collected at enrollment. Lung function and FOT were examined every 6 months until March 2016. Annual changes in FEV 1 and FOT parameters were obtained from the slope of the linear regression curve. The patients were divided into 2 groups based on exacerbation history. Fifty-one of 58 patients with COPD were enrolled in this study. The median follow-up period was 57 (52-59) months. Twenty-five (49%) patients experienced exacerbations. A significant annual decline in FEV 1 and respiratory system impedance were shown. Additionally, annual changes in FEV 1 , respiratory system resistance at 5 Hz, respiratory system reactance at 5 Hz, and resonant frequency were greater in patients with exacerbations than in those without exacerbations. Exacerbations of COPD lead not only to a decline in lung function but also to an increase in respiratory system impedance.

  1. Predictors of deterioration of lung function in Polish children with cystic fibrosis.

    PubMed

    Olszowiec-Chlebna, Małgorzata; Koniarek-Maniecka, Agnieszka; Stelmach, Włodzimierz; Smejda, Katarzyna; Jerzyńska, Joanna; Majak, Paweł; Białas, Monika; Stelmach, Iwona

    2016-04-01

    Severity of lung disease varies in patients with the same CFTR genotype. It suggests that other factors affect the severity of cystic fibrosis (CF). The aim of the study was to identify risk factors that determine lung function decline in Polish cystic fibrosis children. The follow-up time was no less than 5 years of respiratory status observation based on the forced expiratory volume in 1 s value (FEV1). The socio-economic data, perinatal interview, presence of meconium ileus (MI), time of CF diagnosis, initiation of tobramycin inhalation solution (TIS), pancreatic function, sensitization to Aspergillus fumigatus, presence of impaired glucose tolerance (IGT) or diabetes mellitus, chronic bacterial colonization and number of exacerbations and hospitalizations were assessed. The mean age of 61 included children was 13.3 ±7.6 years. Delta F508 homozygosity was detected in 45.9%, 44.3% were delta F508 heterozygous, and 9.8% had other genotypes. FEV1 decline was observed among 20% of patients; the rest of the patients presented stable values of FEV1 during at least 5 years of observation. The most significant predictors related to the decline of FEV1 were presentation of MI (p = 0.0344), IGT (p = 0.0227), number of exacerbations (p = 0.0288), and early Pseudomonas aeruginosa (PA) chronic colonization (p = 0.0165) followed by late TIS initiation after the first detection of PA (p=0.0071). Neither time of diagnosis nor type of CFTR mutation was statistically significant as a predictor of lung deterioration. The presence of MI, IGT, chronic PA colonization, and number of exacerbations are risk factors for lung function deterioration.

  2. [Function in patients with chronic fibrocavernous tuberculosis].

    PubMed

    Nefedov, V B; Popova, L A; Shergina, E A

    2008-01-01

    Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/VC%, PEF, MEF25, MEF50, MEF75, TLC, TGV, residual volume (RV), R(aw), R(in), R(ex), DLCO-SB, DLCO-SS, PaO2, and PaCO2 were determined in 62 patients with chronic fibrocavernous tuberculosis. Lung dysfunctions were detected in 96.8% of the patients. Changes in lung volumes and capacities were found in 90.3%, impaired bronchial patency was in 90.3%, and pulmonary gas exchange dysfunction was in 79.0%. The lung volume and capacity changes appeared as decreased VC and FVC, decreased and increased TLC, TGV, RV; impaired bronchial patency presented as decreased PEF, MEF25, MEF50, MEF75, and FEV1/VC%; and increased R(aw), R(in), R(ex); pulmonary gas exchange dysfunction manifested itself as reduced DLCO-SB, DLCO-SS, PaO2, and decreased and increased PaCO2. The magnitude of the observed functional changes ranges from slight to significant and drastic with a predominance of considerable and drastic changes in lung volumes and capacities and mild impairments of bronchial patency and pulmonary gas exchange function.

  3. Genome-wide assessment of gene-by-smoking interactions in COPD.

    PubMed

    Park, Boram; Koo, So-My; An, Jaehoon; Lee, MoonGyu; Kang, Hae Yeon; Qiao, Dandi; Cho, Michael H; Sung, Joohon; Silverman, Edwin K; Yang, Hyeon-Jong; Won, Sungho

    2018-06-18

    Cigarette smoke exposure is a major risk factor in chronic obstructive pulmonary disease (COPD) and its interactions with genetic variants could affect lung function. However, few gene-smoking interactions have been reported. In this report, we evaluated the effects of gene-smoking interactions on lung function using Korea Associated Resource (KARE) data with the spirometric variables-forced expiratory volume in 1 s (FEV 1 ). We found that variations in FEV 1 were different among smoking status. Thus, we considered a linear mixed model for association analysis under heteroscedasticity according to smoking status. We found a previously identified locus near SOX9 on chromosome 17 to be the most significant based on a joint test of the main and interaction effects of smoking. Smoking interactions were replicated with Gene-Environment of Interaction and phenotype (GENIE), Multi-Ethnic Study of Atherosclerosis-Lung (MESA-Lung), and COPDGene studies. We found that individuals with minor alleles, rs17765644, rs17178251, rs11870732, and rs4793541, tended to have lower FEV 1 values, and lung function decreased much faster with age for smokers. There have been very few reports to replicate a common variant gene-smoking interaction, and our results revealed that statistical models for gene-smoking interaction analyses should be carefully selected.

  4. Lung function in infants with cystic fibrosis diagnosed by newborn screening.

    PubMed

    Linnane, Barry M; Hall, Graham L; Nolan, Gary; Brennan, Siobhan; Stick, Stephen M; Sly, Peter D; Robertson, Colin F; Robinson, Philip J; Franklin, Peter J; Turner, Stephen W; Ranganathan, Sarath C

    2008-12-15

    Progressive lung damage in cystic fibrosis (CF) starts in infancy, and early detection may aid preventative strategies. To measure lung function in infants with CF diagnosed by newborn screening and describe its association with pulmonary infection and inflammation. Infants with CF (n = 68, 6 weeks to 30 months of age) and healthy infants without CF (n = 49) were studied. Forced vital capacity, FEV(0.5), and forced expiratory flows at 75% of exhaled vital capacity (FEF(75)) were measured using the raised-volume rapid thoracoabdominal compression technique. Forty-eight hours later, infants with CF had bronchoalveolar lavage (BAL) for assessment of pulmonary infection and inflammation. In the CF group, the deficit in FEV(0.5) z score increased by -0.77 (95% confidence interval, -1.14 to -0.41; P < 0.001) with each year of age. The mean FEV(0.5) z score did not differ between infants with CF and healthy control subjects less than 6 months of age (-0.06 and 0.02, respectively; P = 0.87). However, the mean FEV(0.5) z score was lower by 1.15 in infants with CF who were older than 6 months of age compared with healthy infants (P < 0.001). FVC and FEF(75) followed a similar pattern. Pulmonary infection and inflammation in BAL samples did not explain the lung function results. Lung function, measured by forced expiration, is normal in infants with CF at the time of diagnosis by newborn screening but is diminished in older infants. These findings suggest that in CF the optimal timing of therapeutic interventions aimed at preserving lung function may be within the first 6 months of life.

  5. Post-tuberculous lung function impairment in a tuberculosis reference clinic in Cameroon.

    PubMed

    Mbatchou Ngahane, Bertrand Hugo; Nouyep, Junior; Nganda Motto, Malea; Mapoure Njankouo, Yacouba; Wandji, Adeline; Endale, Mireille; Afane Ze, Emmanuel

    2016-05-01

    After completion of treatment, a proportion of pulmonary TB (pTB) patients experience lung function impairment which can influence their quality of life. This study aimed to determine the prevalence of lung function impairment in patients treated for pTB and investigate its associated factors. A cross-sectional study was conducted in TB clinic of the Douala Laquintinie Hospital in Cameroon. Patients aged 15 and above who were treated for pTB between 2008 and 2012 were included in the study. Demographic data, respiratory symptoms prior TB diagnosis, comorbidities and chest radiography findings prior to TB treatment were collected. All participants underwent spirometric measurements. Airflow obstruction was defined as a post-bronchodilation FEV1/FVC <70% with FVC >80%, restrictive defects as an FEV1/FVC ratio of ≥70% with an FVC <80% predicted, and mixed defects as FVC of <80% predicted and an FEV1/FVC ratio of <70%. Lung function impairment was defined by the presence of at least one of these three abnormalities. Logistic regression analysis was employed to investigate risk factors of lung function impairment. Of a total of 269 participants included in the study, 146 (54.3%) were male. The median age of participants was 33 years. The median duration of symptoms before diagnosis of TB was 4 weeks [interquartile range (IQR) 3-8]. The prevalence of lung function impairment was 45.4% (95% CI 39-51). The multivariate analysis identified duration of symptoms [OR 1.08; 95% CI (1.01-1.15)] and fibrotic pattern [OR 3.54; 95% CI (1.40-8.95)] as independent risk factors for lung function impairment. Post-tuberculous pulmonary function impairment is frequent in Douala. Sensitization of patient with symptoms of pulmonary TB for an earlier visit to healthcare facilities could reduce the impact of pTB on lung function of patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Indoor molds and lung function in healthy adults.

    PubMed

    Hernberg, Samu; Sripaiboonkij, Penpatra; Quansah, Reginald; Jaakkola, Jouni J K; Jaakkola, Maritta S

    2014-05-01

    Indoor mold exposure is common worldwide and constitutes an important health problem. There are very few studies assessing the relation between mold exposure and lung function levels among non-asthmatic adults. Our objective was to assess the relations between dampness and mold exposures at home and at work and lung function. In particular, we elaborated the importance of different exposure indicators. In a population-based study, 269 non-asthmatic adults from South Finland answered a questionnaire on indoor dampness and mold exposures at home or at work and other factors potentially influencing lung function, and performed spirometry. Multiple linear regression model was applied to study the relations between exposures and spirometric lung function levels. In linear regression adjusting for confounding, FEV1 level was reduced on average 200 ml related to mold odor at home (effect estimate -0.20, 95% CI -0.60 to 0.21) and FVC level was reduced on average 460 ml (-0.46, -0.95 to 0.03) respectively. Exposure to mold odor at home or at work or both was related to reduced FEV1 (-0.15, -0.42 to 0.12) and FVC (-0.22, -0.55 to 0.11) levels. Women had on average 510 ml reduced FEV1 levels (-0.51, -1.0 to 0.03) and 820 ml reduced FVC levels (-0.82, -1.4 to -0.20) related to mold odor exposure at home. Mold odor exposure was related to lower lung function levels among non-asthmatic adults, especially among women. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Bronchopulmonary dysplasia: improvement in lung function between 7 and 10 years of age.

    PubMed

    Blayney, M; Kerem, E; Whyte, H; O'Brodovich, H

    1991-02-01

    To evaluate the natural history of bronchopulmonary dysplasia, we studied the same 32 patients at a mean age of 7 and 10 years. The group as a whole had normal height and weight percentiles, and each child grew along his or her established somatic growth curve. Although some children had abnormal values, the group maintained a normal mean total lung capacity and functional residual capacity. The mean residual volume and the residual volume/total lung capacity ratios were elevated at both ages. At age 7 years the 19 patients (59%) who had a forced expiratory volume in 1 second (FEV1) of less than 80% had "catch up" improvement by 10 years of age (65 +/- 11% to 72 +/- 16% of predicted value; p less than 0.05). All the children who had a normal FEV1 at 7 years of age continued to have a normal FEV1 at age 10 years. Resting single-breath carbon monoxide uptake by the lung was normal when measured at age 10 years. The majority of patients had a positive methacholine challenge test result at both ages, although there was a low incidence of clinically diagnosed asthma. This study demonstrates that patients with bronchopulmonary dysplasia who have normal lung function at age 7 have had normal lung growth and that those with evidence of mild to moderate lung disease have continued lung growth or repair, or both, during their school years.

  8. Ambient air pollution, lung function and airway responsiveness in children with asthma

    PubMed Central

    Ierodiakonou, Despo; Zanobetti, Antonella; Coull, Brent A.; Melly, Steve; Postma, Dirkje S.; Boezen, H. Marike; Vonk, Judith M.; Williams, Paul V.; Shapiro, Gail G.; McKone, Edward F.; Hallstrand, Teal S.; Koenig, Jane Q.; Schildcrout, Jonathan S.; Lumley, Thomas; Fuhlbrigge, Anne N.; Koutrakis, Petros; Schwartz, Joel; Weiss, Scott T.; Gold, Diane R

    2016-01-01

    Background Although ambient air pollution has been linked to reduced lung function in healthy children, longitudinal analyses of pollution effects in asthma are lacking. Objective To investigate pollution effects in a longitudinal asthma study and effect modification by controller medications. Methods We examined associations of lung function and methacholine responsiveness (PC20) with ozone, carbon monoxide (CO), nitrogen dioxide (NO2) and sulfur dioxide (SO2) levels in 1,003 asthmatic children participating in a 4-year clinical trial. We further investigated whether budesonide and nedocromil modified pollution effects. Daily pollutant concentrations were linked to zip/postal code of residence. Linear mixed models tested associations of within-subject pollutant concentrations with FEV1 and FVC %predicted, FEV1/FVC and PC20, adjusting for seasonality and confounders. Results Same-day and 1-week average CO levels were negatively associated with post-bronchodilator %predicted FEV1 (change(95%CI) per IQR: −0.33(−0.49, −0.16), −0.41(−0.62, −0.21), respectively) and FVC (−0.19(−0.25, −0.07), −0.25(−0.43, −0.07)). Longer-term four-month averages of CO were negatively associated with prebronchodilator %predicted FEV1 and FVC (−0.36(−0.62, −0.10), −0.21(−0.42, −0.01)). Four-month averaged CO and ozone levels were negatively associated with FEV1/FVC (p<0.05). Increased four-month average NO2 levels were associated with reduced post-bronchodilator FEV1 and FVC %predicted. Long-term exposures to SO2 were associated with reduced PC20 (%change(95%CI) per IQR:-6(-11,-1.5)). Treatment augmented the negative short-term CO effect on PC20. Conclusions Air pollution adversely influences lung function and PC20 in asthmatic children. Treatment with controller medications may not protect but worsens the CO effects on PC20. This clinical trial design evaluates modification of pollution effects by treatment without confounding by indication. PMID:26187234

  9. Lung function parameters of healthy Sri Lankan Tamil young adults.

    PubMed

    Balasubramaniam, M; Sivapalan, K; Thuvarathipan, R

    2014-06-01

    To establish reference norms of lung function parameters for healthy Sri Lankan Tamil young adults. Cross sectional study of Tamil students at the Faculty of Medicine, Jaffna. Healthy non smoking students of Sri Lankan Tamil ethnic group were enrolled. Age, height, weight, BMI and spirometric measurements (Micro Quark) were recorded in 267 participants (137 females and 130 males). Height was significantly correlated with (p<0.05) all the lung function parameters except FEV1%, PEFR and MEF75 in males. Prediction equations were derived by regression analysis based on the height as an independent variable. Predicted lung function values for a particular age and height were lower than values predicted for Pakistanis, Kelatanese Malaysians and eastern Indians. The values were comparable to south Indians in Madras. Our FVC values of males and VC of females were closer to Sri Lankan Sinhalese. FEV1 and FEF25-75 in males were slightly higher and FVC, FEV1 and FEF25-75 in females were slightly lower in Tamils. When mean values were compared, these parameters were significantly higher in Tamil males (p<0.001) and significantly lower in Tamil females (p<0.001). These values will be useful in interpreting lung function parameters of the particular age group as there are no published norms for Sri Lankan Tamils. However, our study sample was confined to medical students of 20-28 years which may explain the differences with Sinhalese.

  10. Increased lung function decline in blue-collar workers exposed to welding fumes.

    PubMed

    Thaon, Isabelle; Demange, Valérie; Herin, Fabrice; Touranchet, Annie; Paris, Christophe

    2012-07-01

    There is no consensus at the present time about the effect of welding on lung function decline. This study compared lung function decline between blue-collar workers exposed and not exposed to welding fumes in a French longitudinal cohort of 21,238 subjects aged 37 to 52 years at inclusion. Medical data, occupation, sector of activity, and spirometry were recorded twice by occupational physicians in 1990 and 1995. A job-exposure matrix was used to identify 503 male blue-collar workers exposed to welding fumes and 709 control subjects and to define the weekly duration of exposure to welding fumes. Baseline lung function parameters were higher in workers exposed to welding fumes than in control subjects. After a 5-year follow-up, welding-fume exposure was associated with a nonsignificant decline in FVC (P = .06) and FEV(1) (P = .07) after adjustment for age, pack-years, BMI, and baseline value of the parameter. A significant accelerated decline in FEV(1) (P = .046) was also observed in never smokers exposed to welding fumes. An “exposure-response” relationship was observed between FEV(1) decline and weekly duration of exposure to welding fumes in nonsmokers but not in smokers. Blue-collar workers exposed to welding fumes showed accelerated decline in lung function, which, in nonsmokers, was related to weekly duration of exposure.

  11. Effects of bronchoscopy on lung function in asthmatics.

    PubMed

    Bellinger, Christina; Bleecker, Eugene R; Peters, Stephen; Pascual, Rodolfo; Krings, Jeffrey; Smith, Regina; Hastie, Annette T; Moore, Wendy C

    2017-10-01

    To better understand the changes in pulmonary physiology related to asthma severity following bronchoscopy, we performed scheduled pre- and post-procedure spirometry on subjects undergoing bronchoscopy in our research program. Control subjects and asthma subjects were recruited for bronchoscopy. On the day of bronchoscopy, subjects underwent spirometry pre-bronchoscopy and then up to three sets within 2 hour following the completion of bronchoscopy. A subset of patients had a second bronchoscopy after 2 weeks of treatment with oral prednisolone (40mg daily). A total of 92 subjects had at least one bronchoscopy (12 control subjects, 56 nonsevere asthma (NSA), 24 severe asthma (SA)). The SA and NSA groups had similar decreases in forced expiratory volume in 1 second (FEV1) (-20±13% vs.-19±16%, p = 0.92) and forced vital capacity (FVC) (-20±12% vs.-20±14%, p = 0.80), but no change in FEV1/FVC ratio. The control and NSA group had more rapid recovery of both FEV1 and FVC by 2 hour compared to the SA group (p = 0.01). In the subset of 36 subjects (22 NSA, 14 SA) who underwent a second bronchoscopy following the administration of oral prednisolone for 14 days, steroids resulted in more rapid recovery of lung function (p < 0.04). Following bronchoscopy the lung function of NSA subjects recovered more quickly than SA subjects. Treatment with oral corticosteroids was associated with a quicker recovery of FEV1 which suggests an inflammatory mechanism for these changes in lung compliance.

  12. Ambient air pollution, lung function, and airway responsiveness in asthmatic children.

    PubMed

    Ierodiakonou, Despo; Zanobetti, Antonella; Coull, Brent A; Melly, Steve; Postma, Dirkje S; Boezen, H Marike; Vonk, Judith M; Williams, Paul V; Shapiro, Gail G; McKone, Edward F; Hallstrand, Teal S; Koenig, Jane Q; Schildcrout, Jonathan S; Lumley, Thomas; Fuhlbrigge, Anne N; Koutrakis, Petros; Schwartz, Joel; Weiss, Scott T; Gold, Diane R

    2016-02-01

    Although ambient air pollution has been linked to reduced lung function in healthy children, longitudinal analyses of pollution effects in asthmatic patients are lacking. We sought to investigate pollution effects in a longitudinal asthma study and effect modification by controller medications. We examined associations of lung function and methacholine responsiveness (PC20) with ozone, carbon monoxide (CO), nitrogen dioxide, and sulfur dioxide concentrations in 1003 asthmatic children participating in a 4-year clinical trial. We further investigated whether budesonide and nedocromil modified pollution effects. Daily pollutant concentrations were linked to ZIP/postal code of residence. Linear mixed models tested associations of within-subject pollutant concentrations with FEV1 and forced vital capacity (FVC) percent predicted, FEV1/FVC ratio, and PC20, adjusting for seasonality and confounders. Same-day and 1-week average CO concentrations were negatively associated with postbronchodilator percent predicted FEV1 (change per interquartile range, -0.33 [95% CI, -0.49 to -0.16] and -0.41 [95% CI, -0.62 to -0.21], respectively) and FVC (-0.19 [95% CI, -0.25 to -0.07] and -0.25 [95% CI, -0.43 to -0.07], respectively). Longer-term 4-month CO averages were negatively associated with prebronchodilator percent predicted FEV1 and FVC (-0.36 [95% CI, -0.62 to -0.10] and -0.21 [95% CI, -0.42 to -0.01], respectively). Four-month averaged CO and ozone concentrations were negatively associated with FEV1/FVC ratio (P < .05). Increased 4-month average nitrogen dioxide concentrations were associated with reduced postbronchodilator FEV1 and FVC percent predicted. Long-term exposures to sulfur dioxide were associated with reduced PC20 (percent change per interquartile range, -6% [95% CI, -11% to -1.5%]). Treatment augmented the negative short-term CO effect on PC20. Air pollution adversely influences lung function and PC20 in asthmatic children. Treatment with controller medications might not protect but rather worsens the effects of CO on PC20. This clinical trial design evaluates modification of pollution effects by treatment without confounding by indication. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  13. Aspergillus fumigatus chronic colonization and lung function decline in cystic fibrosis may have a two-way relationship.

    PubMed

    Noni, M; Katelari, A; Dimopoulos, G; Doudounakis, S-E; Tzoumaka-Bakoula, C; Spoulou, V

    2015-11-01

    Aspergillus fumigatus is commonly found in cystic fibrosis (CF) airways. Our aim was to assess the relationship between A. fumigatus chronic colonization and lung function in CF patients. A case-control study of CF patients born from 1989 to 2002 was performed. Medical records were reviewed from the time of initial diagnosis until December 2013. Chronic colonization was defined as two or more positive sputum cultures in a given year. Each patient chronically colonized with A. fumigatus was matched with three control patients (never colonized by A. fumigatus) for age, sex, and year of birth (±3 years). A number of parameters were recorded and analyzed prospectively. The primary outcome measure was the difference in forced expiratory volume in 1 s (FEV1) in percent predicted between groups. Linear mixed models were used for longitudinal analyses to evaluate the relationship between A. fumigatus chronic colonization and lung function during a 7-year period and study the lung function 4 years before the time of enrollment (t0). Twenty patients had chronic colonization and were matched with 60 controls. A significant difference in lung function was detected throughout the 7-year period after adjustment for confounders (est = 8.66, p = 0.020). Four years before t0, FEV1 baseline was the only factor associated with the course of lung function (est = 0.64, p < 0.001) and was significantly different between groups (p = 0.001). In conclusion, a decreased FEV1 baseline appears to be a risk factor for chronic colonization by A. fumigatus, which, in turn, may cause a faster deterioration of lung function.

  14. Cardiovascular Disease Biomarkers Predict Susceptibility or Resistance to Lung Injury in World Trade Center Dust Exposed Firefighters

    PubMed Central

    Weiden, Michael D.; Naveed, Bushra; Kwon, Sophia; Cho, Soo Jung; Comfort, Ashley L.; Prezant, David J.; Rom, William N.; Nolan, Anna

    2013-01-01

    Pulmonary vascular loss is an early feature of chronic obstructive pulmonary disease. Biomarkers of inflammation and of metabolic syndrome, predicts loss of lung function in World Trade Center Lung Injury (WTC-LI). We investigated if other cardiovascular disease (CVD) biomarkers also predicted WTC-LI. This nested case-cohort study used 801 never smoker, WTC exposed firefighters with normal pre-9/11 lung function presenting for subspecialty pulmonary evaluation (SPE) before March, 2008. A representative sub-cohort of 124/801 with serum drawn within six months of 9/11 defined CVD biomarker distribution. Post-9/11/01 FEV1 at subspecialty exam defined cases: susceptible WTC-LI cases with FEV1≤77% predicted (66/801) and resistant WTC-LI cases with FEV1≥107% (68/801). All models were adjusted for WTC exposure intensity, BMI at SPE, age at 9/11, and pre-9/11 FEV1. Susceptible WTC-LI cases had higher levels of Apo-AII, CRP, and MIP-4 with significant RRs of 3.85, 3.93, and 0.26 respectively with an area under the curve (AUC) of 0.858. Resistant WTC-LI cases had significantly higher sVCAM and lower MPO with RRs of 2.24, and 2.89 respectively; AUC 0.830. Biomarkers of CVD in serum six-month post-9/11 predicted either susceptibility or resistance to WTC-LI. These biomarkers may define pathways producing or protecting subjects from pulmonary vascular disease and associated loss of lung function after an irritant exposure. PMID:22903969

  15. Immediate effects of lumacaftor/ivacaftor administration on lung function in patients with severe cystic fibrosis lung disease.

    PubMed

    Popowicz, Natalia; Wood, Jamie; Tai, Anna; Morey, Sue; Mulrennan, Siobhain

    2017-05-01

    Safety-data for lumacaftor/ivacaftor (LUM/IVA) combination therapy in patients with severe lung disease (percent predicted forced expiratory volume in 1s [ppFEV 1 ] <40) remain limited. We report immediate post-dose respiratory-related adverse events in 12 patients with severe cystic fibrosis (CF) lung disease (median [IQR] ppFEV 1 : 34 [31-36]) prescribed LUM/IVA. All patients experienced a decline in ppFEV 1 from baseline at 2-hours (median [IQR] relative change: -19 [-21 to -11]%, p<0.001) that persisted at 24-hours but recovered in most patients at 1-month. No pre- and post-differences in bronchodilator response were observed. Ten (83.3%) patients reported non-severe respiratory-related adverse events within 24-hours of LUM/IVA initiation. At 1-month, eight (67%) patients had persistent symptoms and six (50%) were treated for a pulmonary exacerbation. Our results highlight that LUM/IVA respiratory-related adverse events are common in patients with a ppFEV 1 <40. We recommend close assessment of adverse events. Further studies are required to evaluate the efficacy of LUM/IVA in patients with severe lung disease. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  16. Longitudinal Pulmonary Function in Newly Hired, Non-World Trade Center-Exposed Fire Department City of New York Firefighters

    PubMed Central

    Ye, Fen; Hall, Charles B.; Webber, Mayris P.; Cohen, Hillel W.; Dinkels, Michael; Cosenza, Kaitlyn; Weiden, Michael D.; Nolan, Anna; Christodoulou, Vasilios; Kelly, Kerry J.; Prezant, David J.

    2013-01-01

    Background: Few longitudinal studies characterize firefighters’ pulmonary function. We sought to determine whether firefighters have excessive FEV1 decline rates compared with control subjects. Methods: We examined serial measurements of FEV1 from about 6 months prehire to about 5 years posthire in newly hired male, never smoking, non-Hispanic black and white firefighters, hired between 2003 and 2006, without prior respiratory disease or World Trade Center exposure. Similarly defined Emergency Medical Service (EMS) workers served as control subjects. Results: Through June 30, 2011, 940 firefighters (82%) and 97 EMS workers (72%) who met study criteria had four or more acceptable posthire spirometries. Prehire FEV1% averaged higher for firefighters than EMS workers (99% vs 95%), reflecting more stringent job entry criteria. FEV1 (adjusted for baseline age and height) declined by an average of 45 mL/y both for firefighters and EMS workers, with Fire − EMS decline rate differences averaging 0.2 mL/y (CI, −9.2 to 9.6). Four percent of each group had FEV1 less than the lower limit of normal before hire, increasing to 7% for firefighters and 17.5% for EMS workers, but similar percentages of both groups had adjusted FEV1 decline rates ≥ 10%. Mixed effects modeling showed a significant influence of weight gain but not baseline weight: FEV1 declined by about 8 mL/kg gained for both groups. Adjusting for weight change, FEV1 decline averaged 38 mL/y for firefighters and 34 mL/y for EMS workers. Conclusions: During the first 5 years of duty, firefighters do not show greater longitudinal FEV1 decline than EMS control subjects, and fewer of them develop abnormal lung function. Weight gain is associated with a small loss of lung function, of questionable clinical relevance in this fit and active population. PMID:23188136

  17. Obstructive Airways Disease With Air Trapping Among Firefighters Exposed to World Trade Center Dust

    PubMed Central

    Weiden, Michael D.; Ferrier, Natalia; Nolan, Anna; Rom, William N.; Comfort, Ashley; Gustave, Jackson; Zeig-Owens, Rachel; Zheng, Shugi; Goldring, Roberta M.; Berger, Kenneth I.; Cosenza, Kaitlyn; Lee, Roy; Webber, Mayris P.; Kelly, Kerry J.; Aldrich, Thomas K.

    2010-01-01

    Background: The World Trade Center (WTC) collapse produced a massive exposure to respirable particulates in New York City Fire Department (FDNY) rescue workers. This group had spirometry examinations pre-September 11, 2001, and post-September 11, 2001, demonstrating declines in lung function with parallel declines in FEV1 and FVC. To date, the underlying pathophysiologic cause for this has been open to question. Methods: Of 13,234 participants in the FDNY-WTC Monitoring Program, 1,720 (13%) were referred for pulmonary subspecialty evaluation at a single institution. Evaluation included 919 full pulmonary function tests, 1,219 methacholine challenge tests, and 982 high-resolution chest CT scans. Results: At pulmonary evaluation (median 34 months post-September 11, 2001), median values were FEV1 93% predicted (interquartile range [IQR], 83%-101%), FVC 98% predicted (IQR, 89%-106%), and FEV1/FVC 0.78 (IQR, 0.72-0.82). The residual volume (RV) was 123% predicted (IQR, 106%-147%) with nearly all participants having normal total lung capacity, functional residual capacity, and diffusing capacity of carbon monoxide. Also, 1,051/1,720 (59%) had obstructive airways disease based on at least one of the following: FEV1/FVC, bronchodilator responsiveness, hyperreactivity, or elevated RV. After adjusting for age, gender, race, height and weight, and tobacco use, the decline in FEV1 post-September 11, 2001, was significantly correlated with increased RV percent predicted (P < .0001), increased bronchodilator responsiveness (P < .0001), and increased hyperreactivity (P = .0056). CT scans demonstrated bronchial wall thickening that was significantly associated with the decline in FEV1 post-September 11, 2001 (P = .024), increases in hyperreactivity (P < .0001), and increases in RV (P < .0001). Few had evidence for interstitial disease. Conclusions: Airways obstruction was the predominant physiologic finding underlying the reduction in lung function post-September 11, 2001, in FDNY WTC rescue workers presenting for pulmonary evaluation. PMID:19820077

  18. Lung function in asphalt pavers: a longitudinal study.

    PubMed

    Ulvestad, Bente; Randem, Britt Grethe; Skare, Øivind; Aaløkken, Trond Mogens; Myranek, Georg Karl; Elihn, Karine; Lund, May Brit

    2017-01-01

    To study longitudinal changes in lung function in asphalt pavers and a reference group of road maintenance workers, and to detect possible signs of lung disease by high-resolution computed tomography (HRCT) scans. Seventy-five asphalt pavers and 71 road maintenance workers were followed up with questionnaires and measurements of lung function. Not every worker was tested every year, but most of them had four or more measurement points. The 75 asphalt pavers were also invited to have HRCT scans of the lungs at the end of the follow-up period. Mean annual decline in forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV 1 ) of the asphalt pavers was 58 and 35 ml, respectively. Adjusted for age at baseline, packyears of smoking and BMI, the asphalt pavers had a significant excess annual decline in FVC and FEV 1 compared to the references. The screedmen, the most exposed group of the asphalt pavers, showed a significantly larger decline in FVC than the other asphalt pavers (P = 0.029). Fine intralobular fibrosis without evident cysts was identified with HRCT in three subjects (4 %). We conclude that our findings may indicate an excess annual decline in FVC and FEV 1 related to exposure to asphalt fumes. The screedmen, who carry out their work behind and close to the paving machine, had the largest decline in lung function. The finding of adverse pulmonary effects in asphalt pavers calls for better technological solutions to prevent exposure.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jingbo; Department of Radiation Oncology, Cancer Hospital, Chinese Academic Medical Sciences and Peking Union Medical College, Beijing; Cao, Jianzhong

    Purpose: Poor pulmonary function (PF) is often considered a contraindication to definitive radiation therapy for lung cancer. This study investigated whether baseline PF was associated with radiation-induced lung toxicity (RILT) in patients with non-small cell lung cancer (NSCLC) receiving conformal radiation therapy (CRT). Methods and Materials: NSCLC patients treated with CRT and tested for PF at baseline were eligible. Baseline predicted values of forced expiratory volume in 1 sec (FEV1), forced vital capacity (FVC), and diffusion capacity of lung for carbon monoxide (DLCO) were analyzed. Additional factors included age, gender, smoking status, Karnofsky performance status, coexisting chronic obstructive pulmonary diseasemore » (COPD), tumor location, histology, concurrent chemotherapy, radiation dose, and mean lung dose (MLD) were evaluated for RILT. The primary endpoint was symptomatic RILT (SRILT), including grade ≥2 radiation pneumonitis and fibrosis. Results: There was a total of 260 patients, and SRILT occurred in 58 (22.3%) of them. Mean FEV1 values for SRILT and non-SRILT patients were 71.7% and 65.9% (P=.077). Under univariate analysis, risk of SRILT increased with MLD (P=.008), the absence of COPD (P=.047), and FEV1 (P=.077). Age (65 split) and MLD were significantly associated with SRILT in multivariate analysis. The addition of FEV1 and age with the MLD-based model slightly improved the predictability of SRILT (area under curve from 0.63-0.70, P=.088). Conclusions: Poor baseline PF does not increase the risk of SRILT, and combining FEV1, age, and MLD may improve the predictive ability.« less

  20. Lung function association with outdoor temperature and relative humidity and its interaction with air pollution in the elderly.

    PubMed

    Lepeule, Johanna; Litonjua, Augusto A; Gasparrini, Antonio; Koutrakis, Petros; Sparrow, David; Vokonas, Pantel S; Schwartz, Joel

    2018-04-21

    While the effects of weather variability on cardio-respiratory mortality are well described, research examining the effects on morbidity, especially for vulnerable populations, is warranted. We investigated the associations between lung function and outdoor temperature (T in Celsius degrees (°C)) and relative humidity (RH), in a cohort of elderly men, the Normative Aging Study. Our study included 1103 participants whose forced vital capacity (FVC), forced expiratory volume in one second (FEV 1 ), and weather exposures were assessed one to five times during the period 1995-2011 (i.e. 3162 observations). Temperature and relative humidity were measured at one location 4 h to 7 days before lung function tests. We used linear mixed-effects models to examine the associations with outdoor T and RH. A 5-degree increase in the 3-day moving average T was associated with a significant 0.7% decrease (95%CI: -1.24, -0.20) in FVC and a 5% increase in the 7-day moving average RH was associated with a significant 0.2% decrease (95%CI: -0.40, -0.02) in FVC and FEV 1 . The associations with T were greater when combined with higher exposures of black carbon with a 1.6% decrease (95%CI -2.2; -0.9) in FVC and a 1% decrease (95%CI -1.7; -0.4) in FEV 1 . The relationships between T and RH and lung function were linear. No synergistic effect of T and RH was found. Heat and lung function are two predictors of mortality. Our findings suggest that increases in temperature and relative humidity are related to decreases in lung function, and such observations might be amplified by high black carbon levels. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. A prospective study of the impact of diabetes mellitus on restrictive and obstructive lung function impairment: The Saku study.

    PubMed

    Sonoda, Nao; Morimoto, Akiko; Tatsumi, Yukako; Asayama, Kei; Ohkubo, Takayoshi; Izawa, Satoshi; Ohno, Yuko

    2018-05-01

    To assess the impact of diabetes on restrictive and obstructive lung function impairment. This 5-year prospective study included 7524 participants aged 40-69years without lung function impairment at baseline who underwent a comprehensive medical check-up between April 2008 and March 2009 at Saku Central Hospital. Diabetes was defined by fasting plasma glucose ≥7.0mmol/l (126mg/dl), HbA1c≥6.5% (48mmol/mol), or a history of diabetes, as determined by interviews conducted by the physicians. Restrictive and obstructive lung function impairment were defined as forced vital capacity (FVC) <80% predicted and forced expiratory volume in 1s (FEV 1 ) to FVC ratio (FEV 1 /FVC) <0.70, respectively. Participants were screened until they developed restrictive or obstructive lung function impairment or until March 2014. During the follow-up period, 171 and 639 individuals developed restrictive and obstructive lung function impairment, respectively. Individuals with diabetes had a 1.6-fold higher risk of restrictive lung function impairment than those without diabetes after adjusting for sex, age, height, abdominal obesity, smoking status, exercise habits, systolic blood pressure, HDL-cholesterol, log-transformed high-sensitivity C-reactive protein, and baseline lung function [multivariable-adjusted HR and 95% CI; 1.57 (1.04-2.36)]. In contrast, individuals with diabetes did not have a significantly higher risk of obstructive lung function impairment [multivariable-adjusted HR and 95% CI; 0.93 (0.72-1.21)]. Diabetes was associated with restrictive lung function impairment but not obstructive lung function impairment. Copyright © 2017. Published by Elsevier Inc.

  2. [Cohort study of effects on lung function of coke oven workers exposured to coke oven emissions].

    PubMed

    Zhi, Yongfen; Zhang, Hongming; Li, Weixing; Hu, Zhipeng; Liu, Weihua; Li, Yangfan; Zheng, Jinpin

    2015-07-01

    Through comparative study on pulmonary function damage of coke oven workers exposed to coke oven emissions with the same group before and after five years, and further explore the relationship between the coke oven emissions and injury in pulmonary function of coke oven worker. Select a coking plant in Shanxi 165 coke oven workers (exposed group) and 52 auxiliary workers (control group) for the study, using a uniform questionnaire to collect workers' personal information. Fixed workplace air samples collected periodically. Air samples of benzo (a) pyrene concentrations was measured by high pressure liquid chromatograph. Pulmonary function of research object was measured by portable spirometer respectively in 2009 and 2013, and comparative analysis on it. The concentration of B(a)P was no significant difference in the same area between 5 years in 2009-2013. Compared with 2009, 2013 control workers lung function index and the abnormal rate had no significant difference (P > 0.05). But FVC%, FEV1.0%, MVV%, VC% and FEF25% of exposed workers in 2013 was significantly lower than in 2009, FVC%, FEV1.0%, VC% and FEF25% pulmonary dysfunction rate in 2013 was also significantly higher than in 2009, difference was statistically significant (P < 0.05). Workers emerging pulmonary function abnormalities mainly distributed in furnace roof and side. furnace roof group FVC%, FEV1.0%, VC% additional abnormal number (rate) was significantly higher than furnace floor and the control group (P < 0.05), and furnace side groop was significantly higher than the control group, the difference was statistically significant (P < 0.05). Multivariate Logistic regression analysis showed that after 5 years FVC%, FEV1% and VC% of abnormal lung function emerging adjusted OR of furnace roof workers were 7.939, 5.966 and 4.956. For abnormal of FVC%, FEV1%, VC% and MVV%, the contacting coke seniority is a risk factor. There is a positive interaction between contacting coke seniority and furnace roof (P < 0.05). Coke oven workers lung function damage associated with exposureing to coke oven emissions, coke oven emissions exposure level and exposure time are the main factors of coke oven workers in lung function damage, there is a positive interaction between the two factors.

  3. Obesity disproportionately impacts lung volumes, airflow and exhaled nitric oxide in children.

    PubMed

    Yao, Tsung-Chieh; Tsai, Hui-Ju; Chang, Su-Wei; Chung, Ren-Hua; Hsu, Jing-Ya; Tsai, Ming-Han; Liao, Sui-Ling; Hua, Man-Chin; Lai, Shen-Hao; Chen, Li-Chen; Yeh, Kuo-Wei; Tseng, Yu-Lun; Lin, Wan-Chen; Chang, Su-Ching; Huang, Jing-Long

    2017-01-01

    The current literature focusing on the effect of obesity and overweight on lung function and fraction of exhaled nitric oxide (FeNO) in children, particularly among healthy children of non-European descent, remains controversial. Furthermore, whether the relationship of obesity and overweight with lung function and FeNO in children is modified by atopy is unclear. The objective of this study was to examine the effect of excess weight on lung function parameters and FeNO among Asian children, with a particular focus on exploring the potential effect modification by atopy. We investigated the effect of excess weight on lung function and FeNO in a population sample of 1,717 children aged 5 to 18 years and explored the potential modifying effect of atopy. There were positive associations of body mass index (BMI) z-score with forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), peak expiratory flow (PEF), and forced expiratory flow at 25-75% (FEF25-75) (all P<0.001), after controlling for confounders. The beta coefficient for FEV1 (0.084) was smaller than that for FVC (0.111). In contrast, a negative association was found between BMI z-score and FEV1/FVC ratio (P<0.001) and FeNO (P = 0.03). A consistent pattern of association for lung function variables was observed when stratifying by atopy. There was a negative association of BMI z-score with FeNO in atopic subjects (P = 0.006), but not in non-atopic subjects (P = 0.46). Excess weight disproportionately impacts lung volumes and airflow in children from the general population, independent of atopic status. Excess weight inversely affects FeNO in atopic but not in non-atopic children.

  4. Lung Mass in Smokers.

    PubMed

    Washko, George R; Kinney, Gregory L; Ross, James C; San José Estépar, Raúl; Han, MeiLan K; Dransfield, Mark T; Kim, Victor; Hatabu, Hiroto; Come, Carolyn E; Bowler, Russell P; Silverman, Edwin K; Crapo, James; Lynch, David A; Hokanson, John; Diaz, Alejandro A

    2017-04-01

    Emphysema is characterized by airspace dilation, inflammation, and irregular deposition of elastin and collagen in the interstitium. Computed tomographic studies have reported that lung mass (LM) may be increased in smokers, a finding attributed to inflammatory and parenchymal remodeling processes observed on histopathology. We sought to examine the epidemiologic and clinical associations of LM in smokers. Baseline epidemiologic, clinical, and computed tomography (CT) data (n = 8156) from smokers enrolled into the COPDGene Study were analyzed. LM was calculated from the CT scan. Changes in lung function at 5 years' follow-up were available from 1623 subjects. Regression analysis was performed to assess for associations of LM with forced expiratory volume in 1 second (FEV 1 ) and FEV 1 decline. Subjects with Global Initiative for Chronic Obstructive Lung Disease (GOLD) 1 chronic obstructive pulmonary disease had greater LM than either smokers with normal lung function or those with GOLD 2-4 chronic obstructive pulmonary disease (P < 0.001 for both comparisons). LM was predictive of the rate of the decline in FEV 1 (decline per 100 g, -4.7 ± 1.7 mL/y, P = 0.006). Our cross-sectional data suggest the presence of a biphasic radiological remodeling process in smokers: the presence of such nonlinearity must be accounted for in longitudinal computed tomographic studies. Baseline LM predicts the decline in lung function. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  5. The NHLBI LAM Registry: Prognostic physiological and radiological biomarkers emerge from a 15-year prospective longitudinal analysis.

    PubMed

    Gupta, Nishant; Lee, Hye-Seung; Ryu, Jay H; Taveira-DaSilva, Angelo M; Beck, Gerald J; Lee, Jar-Chi; McCarthy, Kevin; Finlay, Geraldine A; Brown, Kevin K; Ruoss, Stephen J; Avila, Nilo A; Moss, Joel; McCormack, Francis X

    2018-06-22

    The natural history of lymphangioleiomyomatosis is mainly derived from retrospective cohort analyses and remains incompletely understood. A National Institutes of Health LAM Registry was established to define the natural history and identify prognostic biomarkers that can help guide management and decision-making in patients with LAM. A linear mixed effects model was employed to compute the rate of decline of FEV1, and identify variables impacting FEV1 decline among 217 registry patients who enrolled from 1998-2001. Prognostic variables associated with progression to death/lung transplantation were identified using a Cox proportional hazard model. Mean annual decline of FEV1 was 89±53 ml/year, and remained remarkably constant regardless of baseline lung function. FEV1 decline was more rapid in those with greater cyst profusion on CT scan (p=0.02), and in premenopausal subjects (118ml/year) compared to postmenopausal subjects (74ml/year), (p=0.003). There were 26 deaths and 43 lung transplants during the evaluation period. Estimated 5-, 10-, 15-, and 20-year transplant-free survival rates were 95%, 85%, 75%, and 64%, respectively. Postmenopausal status (hazard ratio 0.30, p=0.0002) and higher baseline FEV1 (hazard ratio 0.97, p=0.008) or DLCO (hazard ratio 0.97, p=0.001) were independently associated with a lower risk of progression to death or lung transplantation. The median transplant-free survival in patients with LAM is greater than 20 years. Menopausal status as well as structural and physiological markers of disease severity significantly affect the rate of decline of FEV1 and progression to death or lung transplantation in LAM. Copyright © 2018. Published by Elsevier Inc.

  6. Ventilatory function in rubber processing workers: acute changes over the workshift.

    PubMed Central

    Governa, M; Comai, M; Valentino, M; Antonicelli, L; Rinaldi, F; Pisani, E

    1987-01-01

    When considering rubber tyre manufacturing from an occupational health viewpoint, three areas may be identified in which exposure to respirable materials are potentially harmful: the processing, curing, and talc areas. A study of the ventilatory function of the entire work force employed in the processing area in a rubber tyre manufacturing plant was undertaken to determine whether an acute reduction in lung function occurs over the course of their working shift (the plant worked a three shift system) and whether a chronic exposure to the occupational airborne contaminants causes permanent changes in lung function. The ventilatory function was measured at the worksite at the beginning and immediately after the end of the workshift. No evidence of chronic obstructive pulmonary disease was found and in most cases no significant decline in FEV1 was observed. Only one of the 79 individuals showed a moderate obstruction, measured by the ratio FEV1/FVC which gave the value of 0.55, with no variation over the shift. For non-smokers, the FVC, FEV1, and FEF25-75% were lower in those exposed for more than five years than in those exposed for five years or less. A similar pattern was also observed in the FVC and FEV1 of the smokers. None of these differences was statistically significant. Within each exposure group the pulmonary function of the smokers was lower than that of the non-smokers, but the only significant difference was found in the values of FEF25-75%. Only one man showed a decline in the FEV1/FVC ratio over the shift, but during each shift, a decrease in all the lung function tests was observed. The decrease was smallest during the first of the three shifts. These results are thought to support the hypothesis that there are acute adverse effects over an eight hour shift. Further investigations are needed to discover whether these acute changes in lung function result from a chemical stimulation or irritant receptors in the airways. PMID:3814549

  7. Cross sectional study on lung function of coke oven workers: a lung function surveillance system from 1978 to 1990

    PubMed Central

    Wu, J; Kreis, I; Griffiths, D; Darling, C

    2002-01-01

    Aims: To determine the association between lung function of coke oven workers and exposure to coke oven emissions. Methods: Lung function data and detailed work histories for workers in recovery coke ovens of a steelworks were extracted from a lung function surveillance system. Multiple regressions were employed to determine significant predictors for lung function indices. The first sets of lung function tests for 613 new starters were pooled to assess the selection bias. The last sets of lung function tests for 834 subjects with one or more year of coke oven history were pooled to assess determinants of lung function. Results: Selection bias associated with the recruitment process was not observed among the exposure groups. For subjects with a history of one or more years of coke oven work, each year of working in the most exposed "operation" position was associated with reductions in FEV1 of around 9 ml (p = 0.006, 95% CI: 3 ml to 16 ml) and in FVC of around 12 ml (p = 0.002, 95% CI: 4 ml to 19 ml). Negative effects of smoking on lung function were also observed. Conclusions: Exposure to coke oven emissions was found to be associated with lower FEV1 and FVC. Effects of work exposure on lung function are similar to those found in other studies. PMID:12468747

  8. Ambient particulate matter and lung function growth in Chinese children.

    PubMed

    Roy, Ananya; Hu, Wei; Wei, Fusheng; Korn, Leo; Chapman, Robert S; Zhang, Junfeng Jim

    2012-05-01

    Exposure to particulate matter (PM) has been associated with deficits in lung function growth among children in Western countries. However, few studies have explored this association in developing countries, where PM levels are often substantially higher. Children (n = 3273) 6-12 years of age were recruited from 8 schools in 4 Chinese cities. The lung function parameters of forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV1) were measured using computerized spirometers twice a year for up to 3 years (1993-1996). Dichotomous samplers placed in each schoolyard were used to measure PM2.5 and PM10 (PM with diameter ≤ 2.5 μm and ≤ 10 μm, respectively). Multivariable generalized estimating equations were used to examine the association between the quarterly average PM levels and lung function growth during the period of follow-up. Annual average PM2.5 and PM10 levels in the 4 cities ranged from 57 to 158 μg/m and 95 to 268 μg/m, respectively. In multivariable models, an increase of 10 μg/m of PM2.5 was associated with decreases of 2.7 mL FEV1 (95% confidence interval = -3.5 to -2.0), 3.5 mL FVC (-4.3 to -2.7), 1.4 mL/year FEV1 growth (-1.8 to -0.9), and 1.5 mL/year FVC growth (-2.0 to -1.0). Similar results were seen with PM10 exposure. Exposure to ambient particulate matter was associated with decreased growth in lung function among Chinese children.

  9. Work-related symptoms and dose-response relationships for personal exposures and pulmonary function among woodworkers.

    PubMed

    Mandryk, J; Alwis, K U; Hocking, A D

    1999-05-01

    Four sawmills, a wood chipping mill, and five joineries in New South Wales, Australia, were studied for the effects of personal exposure to wood dust, endotoxins. (1-->3)-beta-D-glucans, Gram-negative bacteria, and fungi on lung function among woodworkers. Personal inhalable and respirable dust sampling was carried out. The lung function tests of workers were conducted before and after a workshift. The mean percentage cross-shift decrease in lung function was markedly high for woodworkers compared with the controls. Dose-response relationships among personal exposures and percentage cross-shift decrease in lung function and percentage predicted lung function were more pronounced among joinery workers compared with sawmill and chip mill workers. Woodworkers had markedly high prevalence of regular cough, phlegm, and chronic bronchitis compared with controls. Significant associations were found between percentage cross-shift decrease in FVC and regular phlegm and blocked nose among sawmill and chip mill workers. Both joinery workers and sawmill and chip mill workers showed significant relationships between percentage predicted lung function (FVC, FEV1, FEV1/FVC, FEF25-75%) and respiratory symptoms. Wood dust and biohazards associated with wood dust are potential health hazards and should be controlled.

  10. Relationship between pulmonary function and indoor air pollution from coal combustion among adult residents in an inner-city area of southwest China

    PubMed Central

    Jie, Y.; Houjin, H.; Xun, M.; Kebin, L.; Xuesong, Y.; Jie, X.

    2014-01-01

    Few studies evaluate the amount of particulate matter less than 2.5 mm in diameter (PM2.5) in relation to a change in lung function among adults in a population. The aim of this study was to assess the association of coal as a domestic energy source to pulmonary function in an adult population in inner-city areas of Zunyi city in China where coal use is common. In a cross-sectional study of 104 households, pulmonary function measurements were assessed and compared in 110 coal users and 121 non-coal users (≥18 years old) who were all nonsmokers. Several sociodemographic factors were assessed by questionnaire, and ventilatory function measurements including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), the FEV1/FVC ratio, and peak expiratory flow rate (PEFR) were compared between the 2 groups. The amount of PM2.5 was also measured in all residences. There was a significant increase in the relative concentration of PM2.5 in the indoor kitchens and living rooms of the coal-exposed group compared to the non-coal-exposed group. In multivariate analysis, current exposure to coal smoke was associated with a 31.7% decrease in FVC, a 42.0% decrease in FEV1, a 7.46% decrease in the FEV1/FVC ratio, and a 23.1% decrease in PEFR in adult residents. The slope of lung function decrease for Chinese adults is approximately a 2-L decrease in FVC, a 3-L decrease in FEV1, and an 8 L/s decrease in PEFR per count per minute of PM2.5 exposure. These results demonstrate the harmful effects of indoor air pollution from coal smoke on the lung function of adult residents and emphasize the need for public health efforts to decrease exposure to coal smoke. PMID:25296361

  11. Lung function in type 2 diabetes: the Normative Aging Study.

    PubMed

    Litonjua, Augusto A; Lazarus, Ross; Sparrow, David; Demolles, Debbie; Weiss, Scott T

    2005-12-01

    Cross-sectional studies have noted that subjects with diabetes have lower lung function than non-diabetic subjects. We conducted this analysis to determine whether diabetic subjects have different rates of lung function change compared with non-diabetic subjects. We conducted a nested case-control analysis in 352 men who developed diabetes and 352 non-diabetic subjects in a longitudinal observational study of aging in men. We assessed lung function among cases and controls at three time points: Time0, prior to meeting the definition of diabetes; Time1, the point when the definition of diabetes was met; and Time2, the most recent follow-up exam. Cases had lower forced expiratory volume in 1s (FEV1) and forced vital capacity (FVC) at all time points, even with adjustment for age, height, weight, and smoking. In multiple linear regression models adjusting for relevant covariates, there were no differences in rates of FEV1 or FVC change over time between cases and controls. Men who are predisposed to develop diabetes have decreased lung function many years prior to the diagnosis, compared with men who do not develop diabetes. This decrement in lung function remains after the development of diabetes. We postulate that mechanisms involved in the insulin resistant state contribute to the diminished lung function observed in our subjects.

  12. Pulmonary effects of active smoking and secondhand smoke exposure among adolescent students in Juárez, Mexico.

    PubMed

    Bird, Yelena; Staines-Orozco, Hugo

    2016-01-01

    Youth smoking trends among Latin American countries, including Mexico, are on the rise. Notably, although the high prevalence of smoking in teens has been well documented in the literature, few studies have evaluated the impact of smoking and secondhand smoke (SHS) exposure on their respiratory system. To investigate the effects of smoking and SHS exposure on the respiratory health and lung function among eighth-grade students in Juárez, Mexico. A cross-sectional study was undertaken on a sample of convenience. The study outcomes centered on evaluating 300 students' lung function by spirometry (forced expiratory volume in 1 second [FEV1], forced expiratory volume in 1 second/forced vital capacity ratio [FEV1/FVC], and forced mid-expiratory flow rate [FEF25%-75%]) and their respiratory health (smoking behavior and SHS exposure) by their self-reported responses to a standardized respiratory questionnaire. The study outcomes were compared among three distinct groups: 1) nonsmokers/nonexposed to SHS; 2) nonsmokers/exposed to SHS; and 3) smokers. The majority of the study participants were 14 years old (85%), females (54%), who attended eighth grade in a public school setting (56%). Approximately, half reported being of low socioeconomic status (49%) and nonsmokers/exposed to SHS (49%). The lung function parameters of smokers were found to be lower (FEV1 =62.88±10.25; FEV1/FVC =83.50±14.15; and FEF25%-75% =66.35±12.55) than those recorded for the nonsmokers/exposed to SHS (FEV1 =69.41±11.35; FEV1/FVC =88.75±15.75; and FEF25%-75% =78.90±14.65) and significantly reduced when compared to the nonsmokers/nonexposed to SHS (FEV1 =79.14±13.61; FEV1/FVC =94.88±21.88; and FEF25%-75% =87.36±17.02) (P<0.001). Similarly, respiratory complaints were more prevalent among smokers and those exposed to SHS when compared to nonsmokers/nonexposed to SHS. Our findings suggest that initiation of cigarette smoking and, to a lesser extent, exposure to SHS in adolescence leads to increased respiratory symptoms and reduction of pulmonary function test values. Public health initiatives that aim to prevent smoking initiation, assist in cessation, and lessen SHS exposure of adolescents need to be school-based and employed as early as middle school.

  13. Welding, longitudinal lung function decline and chronic respiratory symptoms: a systematic review of cohort studies.

    PubMed

    Szram, Joanna; Schofield, Susie J; Cosgrove, Martin P; Cullinan, Paul

    2013-11-01

    While the acute respiratory risks of welding are well characterised, more chronic effects, including those on lung function, are less clear. We carried out a systematic review of published longitudinal studies of lung function decline in welders. Original cohort studies documenting two or more sequential measurements of lung function were reviewed. Meta-analysis was carried out on studies with suitable data on forced expiratory volume in 1 s (FEV1). Seven studies were included; their quality (measured on the Newcastle-Ottawa scale) was good, although exposure assessment was limited and the studies showed significant heterogeneity. Five had data suitable for meta-analysis; the pooled estimate of the difference in FEV1 decline between welders and nonwelders was -9.0 mL · year(-1) (95% CI -22.5-4.5; p=0.193). The pooled estimates of difference in annual FEV1 decline between welders and referents who smoked was -13.7 mL · year(-1) (95% CI -33.6-6.3; p=0.179). For welders and referents who did not smoke the estimated difference was -3.8 mL · year(-1) (95% CI -20.2-12.6; p=0.650). Symptom prevalence data were mainly narrative; smoking appeared to have the greatest effect on symptom evolution. Collectively, available longitudinal data on decline of lung function in welders and respiratory symptoms suggest a greater effect in those who smoke, supporting a focus on smoking cessation as well as control of fume exposure in this trade. Further prospective studies are required to confirm these findings.

  14. Association between lung function in adults and plasma DDT and DDE levels: results from the Canadian Health Measures Survey.

    PubMed

    Ye, Ming; Beach, Jeremy; Martin, Jonathan W; Senthilselvan, Ambikaipakan

    2015-05-01

    Although DDT [1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane] has been banned in many countries since the 1970s, it may still pose a risk to human respiratory health. In agriculture, DDT exposures have been associated with asthma and chronic bronchitis. However, little is known about the effect of DDT on lung function. We used data on 1,696 participants 20-79 years of age from the Canadian Health Measures Survey (CHMS) and conducted multiple regression analysis to estimate associations between plasma p,p´-DDT/DDE and lung function. Almost all participants (> 99.0%) had detectable concentrations of plasma p,p´-DDE, but only 10.0% had detectable p,p´-DDT. Participants with detectable p,p´-DDT had significantly lower mean FVC (difference = 311 mL; 95% CI: -492, -130; p = 0.003) and FEV1 (difference = 232 mL; 95% CI: -408, -55; p = 0.015) than those without. A 100-ng/g lipid increase in plasma p,p´-DDE was associated with an 18.8-mL decrease in mean FVC (95% CI: -29, -9) and an 11.8-mL decrease in mean FEV1 (95% CI: -21, -3). Neither exposure was associated with FEV1/FVC ratio or FEF25%-75%. DDT exposures, which may have occurred decades ago, were still detectable among Canadians. Plasma DDT and DDE were negatively associated with lung function parameters. Additional research on the potential effects of DDT use on lung function is warranted.

  15. WE-AB-BRA-06: 4DCT-Ventilation: A Novel Imaging Modality for Thoracic Surgical Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vinogradskiy, Y; Jackson, M; Schubert, L

    Purpose: The current standard-of-care imaging used to evaluate lung cancer patients for surgical resection is nuclear-medicine ventilation. Surgeons use nuclear-medicine images along with pulmonary function tests (PFT) to calculate percent predicted postoperative (%PPO) PFT values by estimating the amount of functioning lung that would be lost with surgery. 4DCT-ventilation is an emerging imaging modality developed in radiation oncology that uses 4DCT data to calculate lung ventilation maps. We perform the first retrospective study to assess the use of 4DCT-ventilation for pre-operative surgical evaluation. The purpose of this work was to compare %PPO-PFT values calculated with 4DCT-ventilation and nuclear-medicine imaging. Methods:more » 16 lung cancer patients retrospectively reviewed had undergone 4DCTs, nuclear-medicine imaging, and had Forced Expiratory Volume in 1 second (FEV1) acquired as part of a standard PFT. For each patient, 4DCT data sets, spatial registration, and a density-change based model were used to compute 4DCT-ventilation maps. Both 4DCT and nuclear-medicine images were used to calculate %PPO-FEV1 using %PPO-FEV1=pre-operative FEV1*(1-fraction of total ventilation of resected lung). Fraction of ventilation resected was calculated assuming lobectomy and pneumonectomy. The %PPO-FEV1 values were compared between the 4DCT-ventilation-based calculations and the nuclear-medicine-based calculations using correlation coefficients and average differences. Results: The correlation between %PPO-FEV1 values calculated with 4DCT-ventilation and nuclear-medicine were 0.81 (p<0.01) and 0.99 (p<0.01) for pneumonectomy and lobectomy respectively. The average difference between the 4DCT-ventilation based and the nuclear-medicine-based %PPO-FEV1 values were small, 4.1±8.5% and 2.9±3.0% for pneumonectomy and lobectomy respectively. Conclusion: The high correlation results provide a strong rationale for a clinical trial translating 4DCT-ventilation to the surgical domain. Compared to nuclear-medicine, 4DCT-ventilation is cheaper, does not require a radioactive contrast agent, provides a faster imaging procedure, and has improved spatial resolution. 4DCT-ventilation can reduce the cost and imaging time for patients while providing improved spatial accuracy and quantitative results for surgeons. YV discloses grant from State of Colorado.« less

  16. The influence of polycyclic aromatic hydrocarbons on lung function in a representative sample of the Canadian population.

    PubMed

    Cakmak, Sabit; Hebbern, Chris; Cakmak, Jasmine D; Dales, Robert E

    2017-09-01

    We investigated the associations between exposure to polycyclic aromatic hydrocarbons (PAHs) and selected respiratory physiologic measures in cycles 2 and 3 of the Canadian Health Measures Survey, a nationally representative population sample. Using generalized linear mixed models, we tested the association between selected PAH metabolites and 1-second forced expiratory volume (FEV 1 ), forced vital capacity (FVC), and the ratio between the two (FEV 1 /FVC) in 3531 people from 6 to 79 years of age. An interquartile change in urinary PAH metabolite was associated with significant decrements in FEV 1 and FVC for eight PAHs, 2-hydroxynapthalene, 1-, and 2-hydroxyphenanthrene, 2-, 3-, and 9-hydroxyfluorene and 3- and 4-hydroxyphenanthrene. Exposure to PAH may negatively affect lung function in the Canadian population. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  17. FEV1 is a better predictor of mortality than FVC: the PLATINO cohort study.

    PubMed

    Menezes, Ana Maria B; Pérez-Padilla, Rogelio; Wehrmeister, Fernando César; Lopez-Varela, Maria Victorina; Muiño, Adriana; Valdivia, Gonzalo; Lisboa, Carmen; Jardim, José Roberto B; de Oca, Maria Montes; Talamo, Carlos; Bielemann, Renata; Gazzotti, Mariana; Laurenti, Ruy; Celli, Bartolomé; Victora, Cesar G

    2014-01-01

    To determine whether the presence of chronic obstructive lung disease (COPD) and reduction of lung function parameters were predictors of mortality in a cohort. Population based cohorts were followed in Montevideo, Santiago and Sao Paulo during 5, 6 and 9 years, respectively. Outcomes included all-cause, cardiovascular, respiratory and cancer mortality; exposures were COPD, forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). Cox regression was used for analyses. Sensitivity, specificity, positive and negative predictive values, receiver operator characteristics curves and Youden's index were calculated. Main causes of death were cardiovascular, respiratory and cancer. Baseline COPD was associated with overall mortality (HR = 1.43 for FEV1/FVC

  18. Lung function indices of children exposed to wood smoke in a fishing port in South-South Nigeria.

    PubMed

    Oloyede, Iso P; Ekrikpo, Udeme E; Ekanem, Emmanuel E

    2013-10-01

    Children in the warm rain forest are at risk of having their lung function compromised by a variety of factors, including smoke from wood fires. A total of 358 children from a fishing port and 400 children living in a farm settlement were tested to determine their peak expiratory flow rate (PEFR), forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), forced expiratory volume in 1 s per cent and forced expiratory flow between 25 and 75%. The values for the PEFR, FVC, FEV1, forced expiratory volume in 1 s per cent and forced expiratory flow between 25 and 75% of the subjects were significantly lower than those of the controls (P value for males = <0.001, 0.01, 0.002, 0.01 and <0.001, respectively, whereas for their female counterparts = <0.001, 0.003, 0.001, 0.04 and <0.001, respectively). These deficits were observed to be more with increasing duration of exposure to wood smoke for PEFR, FVC and FEV1. Chronic exposure to fish drying using firewood can impair lung function in children. There is a need for alternative methods of fish preservation for those engaged in fish drying.

  19. Psychosocial stressors and lung function in youth ages 10-17: an examination by stressor, age and gender.

    PubMed

    Bandoli, G; Ghosh, J K; von Ehrenstein, O; Ritz, B

    2017-06-01

    Research on the impact of psychosocial stressors on child and adolescent lung function is uncommon, and has primarily relied either on parents' own stress measures or parent-reported stressors the child experienced, which may be a poor proxy for perceived stress in older children and adolescents. We performed multivariate linear regression of spirometry measures (FVC, FEV1 and FEF25-75) and psychosocial stressors in 584 adolescents in the Los Angeles Family and Neighborhood Survey. We examined family conflict, unsafe neighborhood or school, and the absence of a father in models stratified by gender, adjusting for PM2.5 and potential confounders. We observed reductions in lung function in males related to the absence of a father in the house (FEV1: -176.2 ml, 95% CI -322.7, -29.7) and family conflict (FEV1: -156.2 ml, 95% CI -327.8, 15.5); associations were stronger in older males ages 15-17 years for each stressor (P for interaction of age and sex was 0.009 and 0.06, respectively). This research informs a very small literature on psychosocial stressors and lung function in adolescents. Our finding of differential vulnerability by age and gender warrants further exploration of adolescent psychosocial stressor response on lung function. © The Author 2016. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Characterization of pulmonary function impairments in patients with mucopolysaccharidoses--changes with age and treatment.

    PubMed

    Lin, Shuan-Pei; Shih, Shou-Chuan; Chuang, Chih-Kuang; Lee, Kuo-Sheng; Chen, Ming-Ren; Niu, Dau-Ming; Chiu, Pao Chin; Lin, Shio Jean; Lin, Hsiang-Yu

    2014-03-01

    The mucopolysaccharidoses (MPS) comprise a group of inherited lysosomal storage disorders characterized by deficiencies in enzymes catalyzing the degradation of glycosaminoglycans. Impairment of pulmonary function is an important health problem for patients with MPS. However, there are few published reports on the prevalence and severity of pulmonary dysfunction in relation to age and treatment in this disorder. To evaluate pulmonary function in patients with MPS, we performed spirometry in 35 patients (22 males and 13 females; 1 with MPS I, 12 with MPS II, 16 with MPS IVA, and 6 with MPS VI; mean age, 14.6 ± 5.9 years; age range, 6.4 years to 33 years). Forced vital capacity (FVC), forced expired volume in 1 sec (FEV1), FEV1 to FVC ratio (FEV1/FVC), peak expiratory flow (PEF), and mean forced expiratory flow during the middle half of FVC (FEF25-75% ) were measured. Mean FVC, FEV1 , PEF, and FEF25-75% were 74.2%, 73.9%, 64.7%, and 37.1% of the predicted values, respectively. By spirometric classification, 32 patients (91%) had small airway disease (FEF25-75%  < 65%), 17 (48%) had restrictive lung disease, and 3 (9%) had obstructive lung disease. Percent predicted FVC, FEV1 , and PEF, as well as FEV1 /FVC, were all negatively correlated with age (P < 0.01), such that pubertal and post-pubertal patients had significantly lower values than younger patients. Of eight attenuated MPS II and VI patients who underwent follow-up pulmonary function testing after receiving enzyme replacement therapy (ERT) for 1.5-7.4 years, six showed improvements in % predicted FVC and five improved in % predicted FEV1 . Our additional characterization of the types and prevalence of pulmonary function abnormalities seen in MPS patients should be useful for clinical care. © 2013 Wiley Periodicals, Inc.

  1. Long term effects of prenatal and postnatal airborne PAH exposures on ventilatory lung function of non-asthmatic preadolescent children. Prospective birth cohort study in Krakow.

    PubMed

    Jedrychowski, Wieslaw A; Perera, Frederica P; Maugeri, Umberto; Majewska, Renata; Mroz, Elzbieta; Flak, Elzbieta; Camann, David; Sowa, Agata; Jacek, Ryszard

    2015-01-01

    The main goal of the study was to test the hypothesis that prenatal and postnatal exposures to polycyclic aromatic hydrocarbons (PAH) are associated with depressed lung function in non-asthmatic children. The study sample comprises 195 non-asthmatic children of non-smoking mothers, among whom the prenatal PAH exposure was assessed by personal air monitoring in pregnancy. At the age of 3, residential air monitoring was carried out to evaluate the residential PAH exposure indoors and outdoors. At the age of 5 to 8, children were given allergic skin tests for indoor allergens; and between 5 and 9 years lung function testing (FVC, FEV05, FEV1 and FEF25-75) was performed. The effects of prenatal PAH exposure on lung function tests repeated over the follow-up were adjusted in the General Estimated Equation (GEE) model for the relevant covariates. No association between FVC with prenatal PAH exposure was found; however for the FEV1 deficit associated with higher prenatal PAH exposure (above 37 ng/m(3)) amounted to 53 mL (p=0.050) and the deficit of FEF25-75 reached 164 mL (p=0.013). The corresponding deficits related to postnatal residential indoor PAH level (above 42 ng/m(3)) were 59 mL of FEV1 (p=0.028) and 140 mL of FEF25-75 (p=0.031). At the higher residential outdoor PAH level (above 90 ng/m(3)) slightly greater deficit of FEV1 (71 mL, p=0.009) was observed. The results of the study suggest that transplacental exposure to PAH compromises the normal developmental process of respiratory airways and that this effect is compounded by postnatal PAH exposure. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Changes of Arterial Blood Gases After Different Ranges of Surgical Lung Resection

    PubMed Central

    Cukic, Vesna; Lovre, Vladimir

    2012-01-01

    Introduction: In recent years there has been increase in the number of patients who need thoracic surgery – first of all different types of pulmonary resection because of primary bronchial cancer, and very often among patients whose lung function is impaired due to different degree of bronchial obstruction so it is necessary to assess functional status before and after lung surgery to avoid the development of respiratory insufficiency. Objective: To show the changes in the level of arterial blood gases after various ranges of lung resection. Material and methods: The study was done on 71 patients surgically treated at the Clinic for Thoracic Surgery KCU Sarajevo, who were previously treated at the Clinic for Pulmonary Diseases “Podhrastovi” in the period from 01. 06. 2009. to 01. 09. 2011. Different types of lung resection were made. Patients whose percentage of ppoFEV1 was (prognosed postoperative FEV1) was less than 30% of normal values of FEV1 for that patients were not given a permission for lung resection. We monitored the changes in levels-partial pressures of blood gases (PaO2, PaCO2 and SaO2) one and two months after resection and compared them to preoperative values. As there were no significant differences between the values obtained one and two months after surgery, in the results we showed arterial blood gas analysis obtained two months after surgical resection. Results were statistically analyzed by SPSS and Microsoft Office Excel. Statistical significance was determined at an interval of 95%. Results: In 59 patients (83%) there was an increase, and in 12 patients (17%) there was a decrease of PaO2, compared to preoperative values. In 58 patients (82%) there was a decrease, and in 13 patients (18%) there was an increase in PaCO2, compared to preoperative values. For all subjects (group as whole): The value of the PaO2 was significantly increased after lung surgery compared to preoperative values (p <0.05) so is the value of the SaO2%. The value of the PaCO2 was significantly decreased after lung surgery compared to preoperative values (p <0.05). Respiratory insufficiency was developed in none of patients. Conclusion: If the % ppoFEV1 (% prognosed postoperative FEV1) is bigger than 30% of normal values of FEV1 (according to sex, weight, height, age) in patient planned for lung resection surgery there is no development of respiratory insufficiency after resection. PMID:23922525

  3. [Pulmonary function in patients with focal pulmonary tuberculosis].

    PubMed

    Nefedov, V B; Popova, L A; Shergina, E A

    2008-01-01

    Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/VC%, PEF, MEF25, MEF50, MEF75, TLC, TGV, pulmonary residual volume (PRV), Raw, Rin, Rcx, DLCO-SB, DLCO-SS/VA, PaO2, and PaCO2 were determined in 40 patients with focal pulmonary tuberculosis. Changes were found in lung volumes and capacities in 75%, impaired bronchial patency and pulmonary gas exchange dysfunction were in 57.5 and 25%, respectively. The lung volume and capacity changes appeared mainly as increased TGV and PRV; impaired bronchial patency presented as decreased MEF50, MEF75, and FEV1/VC%; pulmonary gas exchange dysfunction manifested itself as reduced DLCO-SB, PaO2, and PaCO2. The magnitude of the observed functional changes was generally slight. TGV and PRL increased up to 148-187 and 142-223% of the normal values, respectively; MEF50, MEF75, FEV1/VC%, and DLCO decreased to 59-24, 58-26, 78-57, and 78-67% of the normal values and PaO2 and PaCO2 did to 79-69 and 34-30 cm Hg.

  4. Forced Expiratory Volume in 1 Second Variability Helps Identify Patients with Cystic Fibrosis at Risk of Greater Loss of Lung Function.

    PubMed

    Morgan, Wayne J; VanDevanter, Donald R; Pasta, David J; Foreman, Aimee J; Wagener, Jeffrey S; Konstan, Michael W

    2016-02-01

    To evaluate several alternative measures of forced expiratory volume in 1 second percent predicted (FEV1 %pred) variability as potential predictors of future FEV1 %pred decline in patients with cystic fibrosis. We included 13,827 patients age ≥6 years from the Epidemiologic Study of Cystic Fibrosis 1994-2002 with ≥4 FEV1 %pred measurements spanning ≥366 days in both a 2-year baseline period and a 2-year follow-up period. We predicted change from best baseline FEV1 %pred to best follow-up FEV1 %pred and change from baseline to best in the second follow-up year by using multivariable regression stratified by 4 lung-disease stages. We assessed 5 measures of variability (some as deviations from the best and some as deviations from the trend line) both alone and after controlling for demographic and clinical factors and for the slope and level of FEV1 %pred. All 5 measures of FEV1 %pred variability were predictive, but the strongest predictor was median deviation from the best FEV1 %pred in the baseline period. The contribution to explanatory power (R(2)) was substantial and exceeded the total contribution of all other factors excluding the FEV1 %pred rate of decline. Adding the other variability measures provided minimal additional value. Median deviation from the best FEV1 %pred is a simple metric that markedly improves prediction of FEV1 %pred decline even after the inclusion of demographic and clinical characteristics and the FEV1 %pred rate of decline. The routine calculation of this variability measure could allow clinicians to better identify patients at risk and therefore in need of increased intervention. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Air pollution and fuel vapour induced changes in lung functions: are fuel handlers safe?

    PubMed

    Chawla, Anuj; Lavania, A K

    2008-01-01

    Automobile exhaust derived air pollutants have become a major health hazard. Coupled with the inhalation of fuel vapour, as occurs in petrol station workers, this may lead to significant impairment of lung function. Spirometric lung functions were studied in 58 petrol station workers to examine this possibility. The forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), forced expiratory flow 25%-75% (FEF25-75) and peak expiratory flow (PEF) were recorded and analysed separately for smokers and non-smokers. The workers were divided into 5 groups for analysis of data based on the number of years of work in the petrol pumps. Outdoor air analysis was also carried out. The FVC, FEV1 and PEF declined significantly with increasing years of work in petrol stations in both smokers and non-smokers. Smoking as an independent variable was found to affect the FEV1 significantly but not FVC or PEF. The FEF25-75 was found to be the most affected spirometric value with a significant reduction with increasing years of work. Smoking as such did not affect it. Oxides of nitrogen (NOx), suspended particulate matter (SPM) and particulate matter less than 10 microns (PM10) in outdoor air were higher than the national ambient air quality standards. Exposure to automobile exhaust and fuel vapour impairs lung function in a time-dependent manner. Cigarette smoking appears to accelerate the decline.

  6. Lung function decline over 25 years of follow-up among black and white adults in the ARIC study cohort.

    PubMed

    Mirabelli, Maria C; Preisser, John S; Loehr, Laura R; Agarwal, Sunil K; Barr, R Graham; Couper, David J; Hankinson, John L; Hyun, Noorie; Folsom, Aaron R; London, Stephanie J

    2016-04-01

    Interpretation of longitudinal information about lung function decline from middle to older age has been limited by loss to follow-up that may be correlated with baseline lung function or the rate of decline. We conducted these analyses to estimate age-related decline in lung function across groups of race, sex, and smoking status while accounting for dropout from the Atherosclerosis Risk in Communities Study. We analyzed data from 13,896 black and white participants, aged 45-64 years at the 1987-1989 baseline clinical examination. Using spirometry data collected at baseline and two follow-up visits, we estimated annual population-averaged mean changes in forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) by race, sex, and smoking status using inverse-probability-weighted independence estimating equations conditioning-on-being-alive. Estimated rates of FEV1 decline estimated using inverse-probability-weighted independence estimating equations conditioning on being alive were higher among white than black participants at age 45 years (e.g., male never smokers: black: -29.5 ml/year; white: -51.9 ml/year), but higher among black than white participants by age 75 (black: -51.2 ml/year; white: -26). Observed differences by race were more pronounced among men than among women. By smoking status, FEV1 declines were larger among current than former or never smokers at age 45 across all categories of race and sex. By age 60, FEV1 decline was larger among former and never than current smokers. Estimated annual declines generated using unweighted generalized estimating equations were smaller for current smokers at younger ages in all four groups of race and sex compared with results from weighted analyses that accounted for attrition. Using methods accounting for dropout from an approximately 25-year health study, estimated rates of lung function decline varied by age, race, sex, and smoking status, with largest declines observed among current smokers at younger ages. Published by Elsevier Ltd.

  7. Low-grade systemic inflammation: a partial mediator of the relationship between diabetes and lung function.

    PubMed

    Giovannelli, Jonathan; Trouiller, Philippe; Hulo, Sébastien; Chérot-Kornobis, Natalie; Ciuchete, Alina; Edmé, Jean-Louis; Matran, Régis; Amouyel, Philippe; Meirhaeghe, Aline; Dauchet, Luc

    2018-01-01

    An association has been consistently found between diabetes mellitus and decreased lung function. We evaluated to what extent low-grade inflammation (as measured by the level of high-sensitivity C-reactive protein [hs-CRP]) could explain this relationship. A sample of 1878 middle-aged adults from the cross-sectional Enquête Littoral Souffle Air Biologie Environnement survey without self-reported pulmonary and atherosclerosis disease was included. A mediation analysis was performed to assess and quantify the hs-CRP level as a mediator of the relationship between diabetes and lung function. Diabetes was associated with higher hs-CRP level (+22.9%, 95% confidence interval = [5.1, 43.6]). The hs-CRP (>4 vs. ≤1 mg/L) was associated with lower percentage predicted values for the forced expiratory volume in the first second (FEV1) (-4% [-6.1, -1.9]) and forced vital capacity (FVC) (-4.4% [-6.5, -2.3]). Diabetes was associated with FEV1 (-3.5% [-5.8, -1.3]) and FVC (-3.6% [-5.9, -1.3]). The proportion of the effect that is mediated by hs-CRP was 12% [2.4, 37] and 13% [3.7, 39.4] for FEV1 and FVC, respectively. Our results suggest that low-grade systemic inflammation could only explain a small part of the relationship between diabetes and lung function. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Associations of IL6 polymorphisms with lung function decline and COPD

    PubMed Central

    He, Jian-Qing; Foreman, Marilyn G.; Shumansky, Karey; Zhang, Xuekui; Akhabir, Loubna; Sin, Don D; Man, S F Paul; DeMeo, Dawn L.; Litonjua, Augusto A.; Silverman, Edwin K.; Connett, John E; Anthonisen, Nicholas R; Wise, Robert A; Paré, Peter D; Sandford, Andrew J

    2010-01-01

    Background Interleukin-6 (IL6) is a pleiotropic pro-inflammatory and immunomodulatory cytokine which likely plays an important role in the pathogenesis of COPD. There is a functional single nucleotide polymorphism (SNP), −174G/C, in the promoter region of IL6. We hypothesized that IL6 SNPs influence susceptibility for impaired lung function and COPD in smokers. Methods Seven and 5 SNPs in IL6 were genotyped in two nested case-control samples derived from the Lung Health Study (LHS) based on phenotypes of rate of decline of forced expiratory volume in one second (FEV1) over 5 years and baseline FEV1 at the beginning of the LHS. Serum IL6 concentrations were measured for all subjects. A partially overlapping panel of 9 IL6 SNPs was genotyped in 389 COPD cases from the National Emphysema Treatment Trial (NETT) and 420 controls from the Normative Aging Study (NAS). Results In the LHS, three IL6 SNPs were associated with FEV1 decline (0.023 ≤ P ≤ 0.041 in additive models). Among them the IL6_−174C allele was associated with rapid decline of lung function. The association was more significant in a genotype-based analysis (P = 0.006). In the NETT-NAS study, IL6_−174G/C and four other IL6 SNPs, all of which are in linkage disequilibrium with IL6_−174G/C, were associated with susceptibility to COPD (0.01 ≤ P ≤ 0.04 in additive genetic models). Conclusion Our results suggest that the IL6_−174G/C SNP is associated with rapid decline of FEV1 and susceptibility to COPD in smokers. PMID:19359268

  9. Decreased response to inhaled steroids in overweight and obese asthmatic children.

    PubMed

    Forno, Erick; Lescher, Rachel; Strunk, Robert; Weiss, Scott; Fuhlbrigge, Anne; Celedón, Juan C

    2011-03-01

    The mechanisms and consequences of the observed association between obesity and childhood asthma are unclear. We sought to determine the effect of obesity on treatment responses to inhaled corticosteroids in asthmatic children. We performed a post hoc analysis to evaluate the interaction between body mass index (BMI) and treatment with inhaled budesonide on lung function in the Childhood Asthma Management Program trial. Participants were then stratified into overweight/obese and nonoverweight groups, and their response to inhaled budesonide was analyzed longitudinally over the 4 years of the trial. There was a significant interaction between BMI and budesonide for prebronchodilator FEV(1)/forced vital capacity (FVC) ratio (P = .0007) and bronchodilator response (BDR; P = .049) and a nonsignificant trend for an interaction between BMI and budesonide on prebronchodilator FEV(1) (P = .15). Nonoverweight children showed significant improvement with inhaled budesonide in lung function (FEV(1), FEV(1)/FVC ratio, and BDR) during the early (years 1-2) and late (years 3-4) stages of the trial. Overweight/obese children had improved FEV(1) and BDR during the early but not the late stage of the trial and showed no improvement in FEV(1)/FVC ratio. When comparing time points at which both groups showed a significant response, the degree of improvement among nonoverweight children was significantly greater than in overweight/obese children at most visits. Nonoverweight children had a 44% reduction in the risk of emergency department visits or hospitalizations throughout the trial (P = .001); there was no reduction in risk among overweight/obese children (P = .97). Compared with children of normal weight, overweight/obese children in the Childhood Asthma Management Program showed a decreased response to inhaled budesonide on measures of lung function and emergency department visits/hospitalizations for asthma. Copyright © 2011 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  10. Glucocorticoid Receptor Hetero-Complex Gene STIP1 Is Associated with Improved Lung Function in Asthmatics Treated with Inhaled Corticosteroids

    PubMed Central

    Hawkins, Gregory A.; Lazarus, Ross; Smith, Richard S.; Tantisira, Kelan G.; Meyers, Deborah A.; Peters, Stephen P.; Weiss, Scott T.; Bleecker, Eugene R.

    2015-01-01

    Background Corticosteroids exert their anti-inflammatory action by binding and activating the intracellular the glucocorticoid receptor (GR) hetero-complex. Objective Evaluate the genes HSPCB, HSPCA, STIP1, HSPA8, DNAJB1, PTGES3, FKBP5, and FKBP4 on corticosteroid response. Methods Caucasian asthmatics (382) randomized to once daily flunisolide or conventional inhaled corticosteroid therapy were genotyped. Outcome measures were baseline FEV1, % predicted FEV1, and % change in FEV1 after corticosteroid treatment. Multivariable analyses adjusted for age, gender, and height, were performed fitting the most appropriate genetic model based on quantitative mean derived from ANOVA models to determine if there was an independent effect of polymorphisms on change in FEV1 independent of baseline level. Results Positive recessive model correlations for STIP1 SNPs were observed for baseline FEV1 [rs4980524, p=0.009; rs6591838, p=0.0045; rs2236647, p=0.002; and rs2236648; p=0.013], baseline % predicted FEV1 [rs4980524, p=0.002; rs6591838, p=0.017; rs2236647, p=0.003; and rs2236648; p=0.008] ; % change in FEV1 at 4 weeks [rs4980524, p=0.044; rs6591838, p=0.016; rs2236647; p=0.01] and 8 weeks therapy [rs4980524, p=0.044; rs6591838, p=0.016; rs2236647; p=0.01]. Haplotypic associations were observed for baseline FEV1 and % change in FEV1 at 4 weeks therapy [p=0.05 and p=0.01, respectively]. Significant trends towards association were observed for baseline % predicted FEV1 and % change in FEV1 at 8 weeks therapy. Positive correlations between haplotypes and % change in FEV1 were also observed. Conclusions STIP1 genetic variations may play a role in regulating corticosteroid response in asthmatics with reduced lung function. Replication in a second asthma population is required to confirm these observations. Clinical Implications Identifying genes that regulate corticosteroid responses could allow a priori determination of individual responses to corticosteroid therapy, leading to more effective dosing and/or selection of drug therapies for treating asthma. PMID:19254810

  11. Reductions in pulmonary function detected in patients with lymphangioleiomyomatosis: An analysis of the Japanese National Research Project on Intractable Diseases database.

    PubMed

    Hayashida, Mie; Yasuo, Masanori; Hanaoka, Masayuki; Seyama, Kuniaki; Inoue, Yoshikazu; Tatsumi, Koichiro; Mishima, Michiaki

    2016-05-01

    In lymphangioleiomyomatosis (LAM), predicting lung disease progression is essential for treatment planning. However, no previous Japanese studies have attempted to predict the reductions in pulmonary function that occur in LAM patients. The data for 89 LAM patients who had undergone ≥3 spirometry tests and whose data had been registered in the Japanese National Research Project on Intractable Diseases database between October 2009 and March 2014 were analyzed after excluding patients who had undergone (1) a lung transplant; (2) mTOR inhibitor treatment; or (3) thoracic drainage, pleurodesis, surgery, or thoracic duct ligation during the study period. The rates of change (slope) in pulmonary parameters were calculated, and their associations with clinical background factors were investigated. Among the whole study population, the median (quartiles) slope of forced expiratory volume in one second (FEV1) was -46.7 (-95.2; -15.0)mL per year. Episodes of conservatively treated pneumothorax during the study period were found to be associated with rapid reductions in FEV1 (% predicted). Pregnancy during the study period was associated with a reduction in FEV1 (% predicted). When the patients were divided into those who exhibited initial FEV1 (% predicted) values of >70% (Group A) and ≤70% (Group B), Group B displayed significantly faster reductions in FEV1 (% predicted) than Group A. LAM patients whose initial FEV1 (% predicted) values are ≤70% subsequently exhibit rapid reductions in their FEV1 values, and hence, require treatment. However, the FEV1 reduction rate varies markedly among individuals and should be monitored in all cases. Copyright © 2015 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  12. Clinical Validation of 4-Dimensional Computed Tomography Ventilation With Pulmonary Function Test Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brennan, Douglas; Schubert, Leah; Diot, Quentin

    Purpose: A new form of functional imaging has been proposed in the form of 4-dimensional computed tomography (4DCT) ventilation. Because 4DCTs are acquired as part of routine care for lung cancer patients, calculating ventilation maps from 4DCTs provides spatial lung function information without added dosimetric or monetary cost to the patient. Before 4DCT-ventilation is implemented it needs to be clinically validated. Pulmonary function tests (PFTs) provide a clinically established way of evaluating lung function. The purpose of our work was to perform a clinical validation by comparing 4DCT-ventilation metrics with PFT data. Methods and Materials: Ninety-eight lung cancer patients withmore » pretreatment 4DCT and PFT data were included in the study. Pulmonary function test metrics used to diagnose obstructive lung disease were recorded: forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity. Four-dimensional CT data sets and spatial registration were used to compute 4DCT-ventilation images using a density change–based and a Jacobian-based model. The ventilation maps were reduced to single metrics intended to reflect the degree of ventilation obstruction. Specifically, we computed the coefficient of variation (SD/mean), ventilation V20 (volume of lung ≤20% ventilation), and correlated the ventilation metrics with PFT data. Regression analysis was used to determine whether 4DCT ventilation data could predict for normal versus abnormal lung function using PFT thresholds. Results: Correlation coefficients comparing 4DCT-ventilation with PFT data ranged from 0.63 to 0.72, with the best agreement between FEV1 and coefficient of variation. Four-dimensional CT ventilation metrics were able to significantly delineate between clinically normal versus abnormal PFT results. Conclusions: Validation of 4DCT ventilation with clinically relevant metrics is essential. We demonstrate good global agreement between PFTs and 4DCT-ventilation, indicating that 4DCT-ventilation provides a reliable assessment of lung function. Four-dimensional CT ventilation enables exciting opportunities to assess lung function and create functional avoidance radiation therapy plans. The present work provides supporting evidence for the integration of 4DCT-ventilation into clinical trials.« less

  13. Association of generic health-related quality of life (EQ-5D dimensions) and inactivity with lung function in lung-healthy German adults: results from the KORA studies F4L and Age.

    PubMed

    Luzak, Agnes; Karrasch, Stefan; Wacker, Margarethe; Thorand, Barbara; Nowak, Dennis; Peters, Annette; Schulz, Holger

    2018-03-01

    Among patients with lung disease, decreased lung function is associated with lower health-related quality of life. However, whether this association is detectable within the physiological variability of respiratory function in lung-healthy populations is unknown. We analyzed the association of each EQ-5D-3L dimension (mobility, self-care, usual activities, pain/discomfort, anxiety/depression) and self-reported physical inactivity with spirometric indices in lung-healthy adults. Modulating effects between inactivity and EQ-5D dimensions were considered. 1132 non-smoking, apparently lung-healthy participants (48% male, aged 64 ± 12 years) from the population-based KORA F4L and Age surveys in Southern Germany were analyzed. Associations of each EQ-5D dimension and inactivity with spirometric indices serving as outcomes (forced expiratory volume in 1 s (FEV 1 ), forced vital capacity (FVC), FEV 1 /FVC, and mid-expiratory flow) were examined by linear regression, considering possible confounders. Interactions between EQ-5D dimensions (no problems/any problems) and inactivity (four categories of time spent engaging in exercise: inactive to most active) were assessed. Among all participants 42% reported no problems in any EQ-5D dimension, 24% were inactive and 32% exercised > 2 h/week. After adjustment, FEV 1 was - 99 ml (95% CI - 166; - 32) and FVC was - 109 ml (95% CI - 195; - 24) lower among subjects with mobility problems. Comparable estimates were observed for usual activities. Inactivity was negatively associated with FVC (β-coefficient: - 83 ml, 95% CI - 166; 0), but showed no interactions with EQ-5D. Problems with mobility or usual activities, and inactivity were associated with slightly lower spirometric parameters in lung-healthy adults, suggesting a relationship between perceived physical functioning and volumetric lung function.

  14. Diesel exhaust modulates ozone-induced lung function decrements in healthy human volunteers

    PubMed Central

    2014-01-01

    The potential effects of combinations of dilute whole diesel exhaust (DE) and ozone (O3), each a common component of ambient airborne pollutant mixtures, on lung function were examined. Healthy young human volunteers were exposed for 2 hr to pollutants while exercising (~50 L/min) intermittently on two consecutive days. Day 1 exposures were either to filtered air, DE (300 μg/m3), O3 (0.300 ppm), or the combination of both pollutants. On Day 2 all exposures were to O3 (0.300 ppm), and Day 3 served as a followup observation day. Lung function was assessed by spirometry just prior to, immediately after, and up to 4 hr post-exposure on each exposure day. Functional pulmonary responses to the pollutants were also characterized based on stratification by glutathione S-transferase mu 1 (GSTM1) genotype. On Day 1, exposure to air or DE did not change FEV1 or FVC in the subject population (n = 15). The co-exposure to O3 and DE decreased FEV1 (17.6%) to a greater extent than O3 alone (9.9%). To test for synergistic exposure effects, i.e., in a greater than additive fashion, FEV1 changes post individual O3 and DE exposures were summed together and compared to the combined DE and O3 exposure; the p value was 0.057. On Day 2, subjects who received DE exposure on Day 1 had a larger FEV1 decrement (14.7%) immediately after the O3 exposure than the individuals’ matched response following a Day 1 air exposure (10.9%). GSTM1 genotype did not affect the magnitude of lung function changes in a significant fashion. These data suggest that altered respiratory responses to the combination of O3 and DE exposure can be observed showing a greater than additive manner. In addition, O3-induced lung function decrements are greater with a prior exposure to DE compared to a prior exposure to filtered air. Based on the joint occurrence of these pollutants in the ambient environment, the potential exists for interactions in more than an additive fashion affecting lung physiological processes. PMID:25178924

  15. Effects of a simple prototype respiratory muscle trainer on respiratory muscle strength, quality of life and dyspnea, and oxidative stress in COPD patients: a preliminary study.

    PubMed

    Leelarungrayub, Jirakrit; Pinkaew, Decha; Puntumetakul, Rungthip; Klaphajone, Jakkrit

    2017-01-01

    The aim of this study was to evaluate the efficiency of a simple prototype device for training respiratory muscles in lung function, respiratory muscle strength, walking capacity, quality of life (QOL), dyspnea, and oxidative stress in patients with COPD. Thirty COPD patients with moderate severity of the disease were randomized into three groups: control (n=10, 6 males and 4 females), standard training (n=10, 4 males and 6 females), and prototype device (n=10, 5 males and 5 females). Respiratory muscle strength (maximal inspiratory pressure [PImax] and maximal expiratory pressure [PEmax]), lung function (forced vital capacity [FVC], percentage of FVC, forced expiratory volume in 1 second [FEV 1 ], percentage of FEV 1 [FEV 1 %], and FEV 1 /FVC), 6-minute walking distance (6MWD), QOL, and oxidative stress markers (total antioxidant capacity [TAC]), glutathione (GSH), malondialdehyde (MDA), and nitric oxide (NO) were evaluated before and after 6 weeks of training. Moreover, dyspnea scores were assessed before; during week 2, 4, and 6 of training; and at rest after training. All parameters between the groups had no statistical difference before training, and no statistical change in the control group after week 6. FVC, FEV 1 /FVC, PImax, PEmax, QOL, MDA, and NO showed significant changes after 6 weeks of training with either the standard or prototype device, compared to pre-training. FEV 1 , FEV 1 %, 6MWD, TAC, and GSH data did not change statistically. Furthermore, the results of significant changes in all parameters were not statistically different between training groups using the standard and prototype device. The peak dyspnea scores increased significantly in week 4 and 6 when applying the standard or prototype device, and then lowered significantly at rest after 6 weeks of training, compared to pre-training. This study proposes that a simple prototype device can be used clinically in COPD patients as a standard device to train respiratory muscles, improving lung function and QOL, as well as involving MDA and NO levels.

  16. Impulse oscillometry at preschool age is a strong predictor of lung function by flow-volume spirometry in adolescence.

    PubMed

    Lauhkonen, Eero; Riikonen, Riikka; Törmänen, Sari; Koponen, Petri; Nuolivirta, Kirsi; Helminen, Merja; Toikka, Jyri; Korppi, Matti

    2018-05-01

    The transition from early childhood wheezing to persistent asthma is linked to lung function impairment over time. Little is known how the methods used to study lung function at different ages correlate longitudinally. Sixty-four children with a history of hospitalization for bronchiolitis before 6 months of age were prospectively studied with impulse oscillometry (IOS) at the mean age of 6.3 years and these preschool IOS results were compared with flow-volume spirometry (FVS) measurements at mean age of 11.4 years. The baseline respiratory system resistance at 5 Hz (Rrs5) showed a modest statistically significant correlation with all baseline FVS parameters except FVC. The post-bronchodilator (post-BD) Rrs5 showed a modest statistically significant correlation with post-BD FEV 1 and FEV 1 /FVC. The bronchodilator-induced decrease in Rrs5 showed a modest statistically significant correlation with the percent increase in FEV 1 . Baseline and post-BD respiratory reactance at 5 Hz (Xrs5) showed a modest statistically significant correlation with baseline and post-BD FVS parameters except post-BD FEV 1 /FVC, respectively, and post-BD Xrs5 showed a strong correlation with post-BD FVC (ρ = 0.61) and post-BD FEV 1 (ρ = 0.59). In adjusted linear regression, preschool Xrs5 remained as a statistically significant independent predictor of FVS parameters in adolescence; the one-unit decrease in the Z-score of preschool post-BD Xrs5 predicted 9.6% lower post-BD FEV 1 , 9.3% lower post-BD FVC, and 9.7% lower post-BD MEF 50 when expressed as %-predicted parameters. Persistent post-BD small airway impairment in children with a history of bronchiolitis detected with IOS at preschool age predicted FVS results measured in early adolescence. © 2018 Wiley Periodicals, Inc.

  17. Respiratory Symptoms and Lung Function among Greek Cotton Industry Workers: A Cross-Sectional Study.

    PubMed

    Anyfantis, Ioannis D; Rachiotis, Georgios; Hadjichristodoulou, Cristos; Gourgoulianis, Konstantinos I

    2017-01-01

    Workers in cotton industry are occupationally exposed to various dust-related hazards. The nature of these agents and the respective exposure levels depend on the cotton industry specific sector. These exposures could be associated with respiratory symptoms and changes in lung function parameters. To evaluate associations between occupational exposure and respiratory function as well as reported symptoms in several groups of workers at different stages of the cotton industry in a vertical approach that covers all the major sectors-from cotton ginning to weaving and fabric production. A questionnaire on respiratory symptoms and individual as well as workplace characteristics was completed by 256 workers at the cotton industry and 148 office workers (control group). Both groups underwent spirometry. Workers in cotton industry reported a higher prevalence of severe dyspnea (p=0.002) and wheezing (p=0.004) compared to the control group. Also they were found to have a lower predicted FEV 1 % (p<0.029) and lower FEV 1 /FVC (p<0.001) values. In addition, a higher prevalence of FEV 1 % <80% (p<0.001) and FEV 1 /FVC <70% (p=0.041) were found among textile workers. Similar results were found for non-smoker textile workers compared to non-smoker control group workers. Those working in cotton ginning mills recorded the highest decrease of spirometric values. Duration of employment in cotton industry and smoking use were found to be predictors of lung function decline for cotton industry workers. Occupational exposure to cotton dust was associated with increased prevalence of respiratory symptoms and obstructive pattern in pulmonary function test.

  18. Lung function growth in children with long-term exposure to air pollutants in Mexico City.

    PubMed

    Rojas-Martinez, Rosalba; Perez-Padilla, Rogelio; Olaiz-Fernandez, Gustavo; Mendoza-Alvarado, Laura; Moreno-Macias, Hortensia; Fortoul, Teresa; McDonnell, William; Loomis, Dana; Romieu, Isabelle

    2007-08-15

    Although short-term exposure to air pollution has been associated with acute, reversible lung function decrements, the impact of long-term exposure has not been well established. To evaluate the association between long-term exposure to ozone (O(3)), particulate matter less than 10 mum in diameter (PM(10)), and nitrogen dioxide (NO(2)) and lung function growth in Mexico City schoolchildren. A dynamic cohort of 3,170 children aged 8 years at baseline was followed from April 23, 1996, through May 19, 1999. The children attended 39 randomly selected elementary schools located near 10 air quality monitoring stations and were visited every 6 months. Statistical analyses were performed using general linear mixed models. After adjusting for acute exposure and other potential confounding factors, deficits in FVC and FEV(1) growth over the 3-year follow-up period were significantly associated with exposure to O(3), PM(10), and NO(2). In multipollutant models, an interquartile range (IQR) increase in mean O(3) concentration (IQR, 11.3 ppb) was associated with an annual deficit in FEV(1) of 12 ml in girls and 4 ml in boys, an IQR range (IQR, 36.4 microg/m(3)) increase in PM(10) with an annual deficit in FEV(1) of 11 ml in girls and 15 ml in boys, and an IQR range (IQR, 12.0 ppb) increase in NO(2) with an annual deficit in FEV(1) of 30 ml in girls and 25 ml in boys. We conclude that long-term exposure to O(3), PM(10), and NO(2) is associated with a deficit in FVC and FEV(1) growth among schoolchildren living in Mexico City.

  19. Effects of indoor air pollution on lung function of primary school children in Kuala Lumpur

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Azizi, B.H.; Henry, R.L.

    1990-01-01

    In a cross-sectional study of 7-12 year-old primary school children in Kuala Lumpur city, lung function was assessed by spirometric and peak expiratory flow measurements. Spirometric and peak expiratory flow measurements were successfully performed in 1,214 and 1,414 children, respectively. As expected, the main predictors of forced vital capacity (FVC), forced expiratory volume in one second (FEV1), forced expiratory flow between 25% and 75% of vital capacity (FEF25-75), and peak expiratory flow rate (PEFR) were standing height, weight, age, and sex. In addition, lung function values of Chinese and Malays were generally higher than those of Indians. In multiple regressionmore » models which included host and environmental factors, asthma was associated with significant decreases in FEV1, FEF25-75, and PEFR. However, family history of chest illness, history of allergies, low paternal education, and hospitalization during the neonatal period were not independent predictors of lung function. Children sharing rooms with adult smokers had significantly lower levels of FEF25-75. Exposures to wood or kerosene stoves were, but to mosquito repellents were not, associated with decreased lung function.« less

  20. Adult lung function and long-term air pollution exposure. ESCAPE: a multicentre cohort study and meta-analysis

    PubMed Central

    Adam, Martin; Schikowski, Tamara; Carsin, Anne Elie; Cai, Yutong; Jacquemin, Benedicte; Sanchez, Margaux; Vierkötter, Andrea; Marcon, Alessandro; Keidel, Dirk; Sugiri, Dorothee; Al Kanani, Zaina; Nadif, Rachel; Siroux, Valérie; Hardy, Rebecca; Kuh, Diana; Rochat, Thierry; Bridevaux, Pierre-Olivier; Eeftens, Marloes; Tsai, Ming-Yi; Villani, Simona; Phuleria, Harish Chandra; Birk, Matthias; Cyrys, Josef; Cirach, Marta; de Nazelle, Audrey; Nieuwenhuijsen, Mark J.; Forsberg, Bertil; de Hoogh, Kees; Declerq, Christophe; Bono, Roberto; Piccioni, Pavilio; Quass, Ulrich; Heinrich, Joachim; Jarvis, Deborah; Pin, Isabelle; Beelen, Rob; Hoek, Gerard; Brunekreef, Bert; Schindler, Christian; Sunyer, Jordi; Krämer, Ursula; Kauffmann, Francine; Hansell, Anna L.; Künzli, Nino; Probst-Hensch, Nicole

    2015-01-01

    The chronic impact of ambient air pollutants on lung function in adults is not fully understood. The objective of this study was to investigate the association of long-term exposure to ambient air pollution with lung function in adult participants from five cohorts in the European Study of Cohorts for Air Pollution Effects (ESCAPE). Residential exposure to nitrogen oxides (NO2, NOx) and particulate matter (PM) was modelled and traffic indicators were assessed in a standardised manner. The spirometric parameters forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) from 7613 subjects were considered as outcomes. Cohort-specific results were combined using meta-analysis. We did not observe an association of air pollution with longitudinal change in lung function, but we observed that a 10 μg·m−3 increase in NO2 exposure was associated with lower levels of FEV1 (−14.0 mL, 95% CI −25.8 to −2.1) and FVC (−14.9 mL, 95% CI −28.7 to −1.1). An increase of 10 μg·m−3 in PM10, but not other PM metrics (PM2.5, coarse fraction of PM, PM absorbance), was associated with a lower level of FEV1 (−44.6 mL, 95% CI −85.4 to −3.8) and FVC (−59.0 mL, 95% CI −112.3 to −5.6). The associations were particularly strong in obese persons. This study adds to the evidence for an adverse association of ambient air pollution with lung function in adults at very low levels in Europe. PMID:25193994

  1. Relation of exercise capacity with lung volumes before and after 6-minute walk test in subjects with COPD.

    PubMed

    Wibmer, Thomas; Rüdiger, Stefan; Kropf-Sanchen, Cornelia; Stoiber, Kathrin M; Rottbauer, Wolfgang; Schumann, Christian

    2014-11-01

    There is growing evidence that exercise-induced variation in lung volumes is an important source of ventilatory limitation and is linked to exercise intolerance in COPD. The aim of this study was to compare the correlations of walk distance and lung volumes measured before and after a 6-min walk test (6MWT) in subjects with COPD. Forty-five subjects with stable COPD (mean pre-bronchodilator FEV1: 47 ± 18% predicted) underwent a 6MWT. Body plethysmography was performed immediately pre- and post-6MWT. Correlations were generally stronger between 6-min walk distance and post-6MWT lung volumes than between 6-min walk distance and pre-6MWT lung volumes, except for FEV1. These differences in Pearson correlation coefficients were significant for residual volume expressed as percent of total lung capacity (-0.67 vs -0.58, P = .043), percent of predicted residual volume expressed as percent of total lung capacity (-0.68 vs -0.59, P = .026), inspiratory vital capacity (0.65 vs 0.54, P = .019), percent of predicted inspiratory vital capacity (0.49 vs 0.38, P = .037), and percent of predicted functional residual capacity (-0.62 vs -0.47, P = .023). In subjects with stable COPD, lung volumes measured immediately after 6MWT are more closely related to exercise limitation than baseline lung volumes measured before 6MWT, except for FEV1. Therefore, pulmonary function testing immediately after exercise should be included in future studies on COPD for the assessment of exercise-induced ventilatory constraints to physical performance that cannot be adequately assessed from baseline pulmonary function testing at rest. Copyright © 2014 by Daedalus Enterprises.

  2. FEV1 Is a Better Predictor of Mortality than FVC: The PLATINO Cohort Study

    PubMed Central

    Menezes, Ana Maria B.; Pérez-Padilla, Rogelio; Wehrmeister, Fernando César; Lopez-Varela, Maria Victorina; Muiño, Adriana; Valdivia, Gonzalo; Lisboa, Carmen; Jardim, José Roberto B.; de Oca, Maria Montes; Talamo, Carlos; Bielemann, Renata; Gazzotti, Mariana; Laurenti, Ruy; Celli, Bartolomé; Victora, Cesar G.

    2014-01-01

    Objective To determine whether the presence of chronic obstructive lung disease (COPD) and reduction of lung function parameters were predictors of mortality in a cohort. Materials/Patients and Methods Population based cohorts were followed in Montevideo, Santiago and Sao Paulo during 5, 6 and 9 years, respectively. Outcomes included all-cause, cardiovascular, respiratory and cancer mortality; exposures were COPD, forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). Cox regression was used for analyses. Sensitivity, specificity, positive and negative predictive values, receiver operator characteristics curves and Youden's index were calculated. Results Main causes of death were cardiovascular, respiratory and cancer. Baseline COPD was associated with overall mortality (HR = 1.43 for FEV1/FVC

  3. A genome-wide association study identifies risk loci for spirometric measures among smokers of European and African ancestry.

    PubMed

    Lutz, Sharon M; Cho, Michael H; Young, Kendra; Hersh, Craig P; Castaldi, Peter J; McDonald, Merry-Lynn; Regan, Elizabeth; Mattheisen, Manuel; DeMeo, Dawn L; Parker, Margaret; Foreman, Marilyn; Make, Barry J; Jensen, Robert L; Casaburi, Richard; Lomas, David A; Bhatt, Surya P; Bakke, Per; Gulsvik, Amund; Crapo, James D; Beaty, Terri H; Laird, Nan M; Lange, Christoph; Hokanson, John E; Silverman, Edwin K

    2015-12-03

    Pulmonary function decline is a major contributor to morbidity and mortality among smokers. Post bronchodilator FEV1 and FEV1/FVC ratio are considered the standard assessment of airflow obstruction. We performed a genome-wide association study (GWAS) in 9919 current and former smokers in the COPDGene study (6659 non-Hispanic Whites [NHW] and 3260 African Americans [AA]) to identify associations with spirometric measures (post-bronchodilator FEV1 and FEV1/FVC). We also conducted meta-analysis of FEV1 and FEV1/FVC GWAS in the COPDGene, ECLIPSE, and GenKOLS cohorts (total n = 13,532). Among NHW in the COPDGene cohort, both measures of pulmonary function were significantly associated with SNPs at the 15q25 locus [containing CHRNA3/5, AGPHD1, IREB2, CHRNB4] (lowest p-value = 2.17 × 10(-11)), and FEV1/FVC was associated with a genomic region on chromosome 4 [upstream of HHIP] (lowest p-value = 5.94 × 10(-10)); both regions have been previously associated with COPD. For the meta-analysis, in addition to confirming associations to the regions near CHRNA3/5 and HHIP, genome-wide significant associations were identified for FEV1 on chromosome 1 [TGFB2] (p-value = 8.99 × 10(-9)), 9 [DBH] (p-value = 9.69 × 10(-9)) and 19 [CYP2A6/7] (p-value = 3.49 × 10(-8)) and for FEV1/FVC on chromosome 1 [TGFB2] (p-value = 8.99 × 10(-9)), 4 [FAM13A] (p-value = 3.88 × 10(-12)), 11 [MMP3/12] (p-value = 3.29 × 10(-10)) and 14 [RIN3] (p-value = 5.64 × 10(-9)). In a large genome-wide association study of lung function in smokers, we found genome-wide significant associations at several previously described loci with lung function or COPD. We additionally identified a novel genome-wide significant locus with FEV1 on chromosome 9 [DBH] in a meta-analysis of three study populations.

  4. Associations of children's lung function with ambient air pollution: joint effects of regional and near-roadway pollutants.

    PubMed

    Urman, Robert; McConnell, Rob; Islam, Talat; Avol, Edward L; Lurmann, Frederick W; Vora, Hita; Linn, William S; Rappaport, Edward B; Gilliland, Frank D; Gauderman, W James

    2014-06-01

    Previous studies have reported adverse effects of either regional or near-roadway air pollution (NRAP) on lung function. However, there has been little study of the joint effects of these exposures. To assess the joint effects of NRAP and regional pollutants on childhood lung function in the Children's Health Study. Lung function was measured on 1811 children from eight Southern Californian communities. NRAP exposure was assessed based on (1) residential distance to the nearest freeway or major road and (2) estimated near-roadway contributions to residential nitrogen dioxide (NO2), nitric oxide (NO) and total nitrogen oxides (NOx). Exposure to regional ozone (O3), NO2, particulate matter with aerodynamic diameter <10 µm (PM10) and 2.5 µm (PM2.5) was measured continuously at community monitors. An increase in near-roadway NOx of 17.9 ppb (2 SD) was associated with deficits of 1.6% in forced vital capacity (FVC) (p=0.005) and 1.1% in forced expiratory volume in 1 s (FEV1) (p=0.048). Effects were observed in all communities and were similar for NO2 and NO. Residential proximity to a freeway was associated with a reduction in FVC. Lung function deficits of 2-3% were associated with regional PM10 and PM2.5 (FVC and FEV1) and with O3 (FEV1), but not NO2 across the range of exposure between communities. Associations with regional pollution and NRAP were independent in models adjusted for each. The effects of NRAP were not modified by regional pollutant concentrations. The results indicate that NRAP and regional air pollution have independent adverse effects on childhood lung function. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Longitudinal and Cross-sectional Analyses of Lung Function in Toluene Diisocyanate Production Workers.

    PubMed

    Wang, Mei Lin; Storey, Eileen; Cassidy, Laura D; Doney, Brent; Conner, Patrick R; Collins, James J; Carson, Michael; Molenaar, Don

    2017-12-01

    The aim of this study was to investigate lung function among toluene diisocyanate (TDI) production workers. One hundred ninety-seven U.S workers performed spirometry from 2006 through 2012. Results were compared within the study cohort and with U.S. population measures. A mixed-effects model assessed factors affecting repeated forced expiratory volume in 1 second (FEV1) measurements. The cohort's mean FEV1 and forced vital capacity (FVC) percent reference values, although greater than 90%, were significantly lower and the prevalence of abnormal spirometry (predominantly restrictive pattern) was significantly higher than in the U.S. Differences in lung function among workers with higher cumulative TDI exposure were in the direction of an exposure effect, but not significant. We found little evidence of an adverse effect of TDI exposure on longitudinal spirometry in these workers. The association between TDI exposure and the increasing prevalence of a restrictive pattern needs further exploration.

  6. Longitudinal Lung Function Decrease in Subjects with Spontaneous Healed Pulmonary Tuberculosis.

    PubMed

    Lee, Seung Heon; Kwon, Amy M; Yang, Hae-Chung; Lee, Seung Ku; Kim, Young; Choi, Jong Hyun; Kim, Je Hyeong; Shin, Chol

    2016-01-01

    We compared the longitudinal course of post-bronchodilator Forced Expiratory Volume in 1 second (pFEV1) over a 10-year period in subjects with spontaneous healed pulmonary tuberculosis (SHPTB) with that in normal subjects. We prospectively investigated 339 subjects with SHPTB and 3211 normal subjects. pFEV1 values measured biannually over 10 years were analyzed using mixed effects model. At baseline, there were no differences in gender, smoking amount, and mean height, except mean age (50.0 ± 8.1 VS. 48.1 ± 7.3, P< 0.001) between the SHPTB and normal group. 52% of the 339 participants with SHPTB and 56% of the 3211 normal participants participated till the end of study. According to the final model, the SHPTB group showed significantly larger decrease in the average pFEV1 over the time than the normal group (P< 0.001) adjusted for gender, age, height, smoking pack years, and time effects. Especially, the interaction effect between time and group was statistically significant (P = 0.036). The average lung function in terms of pFEV1 decreases faster in subjects with SHPTB than in normal individuals over time.

  7. Childhood Lung Function Predicts Adult Chronic Obstructive Pulmonary Disease and Asthma-Chronic Obstructive Pulmonary Disease Overlap Syndrome.

    PubMed

    Bui, Dinh S; Burgess, John A; Lowe, Adrian J; Perret, Jennifer L; Lodge, Caroline J; Bui, Minh; Morrison, Stephen; Thompson, Bruce R; Thomas, Paul S; Giles, Graham G; Garcia-Aymerich, Judith; Jarvis, Debbie; Abramson, Michael J; Walters, E Haydn; Matheson, Melanie C; Dharmage, Shyamali C

    2017-07-01

    The burden of chronic obstructive pulmonary disease (COPD) is increasing, yet there are limited data on early life risk factors. To investigate the role of childhood lung function in adult COPD phenotypes. Prebronchodilator spirometry was performed for a cohort of 7-year-old Tasmanian children (n = 8,583) in 1968 who were resurveyed at 45 years, and a selected subsample (n = 1,389) underwent prebronchodilator and post-bronchodilator spirometry. For this analysis, COPD was spirometrically defined as a post-bronchodilator FEV 1 /FVC less than the lower limit of normal. Asthma-COPD overlap syndrome (ACOS) was defined as the coexistence of both COPD and current asthma. Associations between childhood lung function and asthma/COPD/ACOS were examined using multinomial regression. At 45 years, 959 participants had neither current asthma nor COPD (unaffected), 269 had current asthma alone, 59 had COPD alone, and 68 had ACOS. The reweighted prevalence of asthma alone was 13.5%, COPD alone 4.1%, and ACOS 2.9%. The lowest quartile of FEV 1 at 7 years was associated with ACOS (odds ratio, 2.93; 95% confidence interval, 1.32-6.52), but not COPD or asthma alone. The lowest quartile of FEV 1 /FVC ratio at 7 years was associated with ACOS (odds ratio, 16.3; 95% confidence interval, 4.7-55.9) and COPD (odds ratio, 5.76; 95% confidence interval, 1.9-17.4), but not asthma alone. Being in the lowest quartile for lung function at age 7 may have long-term consequences for the development of COPD and ACOS by middle age. Screening of lung function in school age children may identify a high-risk group that could be targeted for intervention. Further research is needed to understand possible modifiers of these associations and develop interventions for children with impaired lung function.

  8. Association between Lung Function in Adults and Plasma DDT and DDE Levels: Results from the Canadian Health Measures Survey

    PubMed Central

    Ye, Ming; Beach, Jeremy; Martin, Jonathan W.

    2014-01-01

    Background Although DDT [1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane] has been banned in many countries since the 1970s, it may still pose a risk to human respiratory health. In agriculture, DDT exposures have been associated with asthma and chronic bronchitis. However, little is known about the effect of DDT on lung function. Methods We used data on 1,696 participants 20–79 years of age from the Canadian Health Measures Survey (CHMS) and conducted multiple regression analysis to estimate associations between plasma p,p´-DDT/DDE and lung function. Results Almost all participants (> 99.0%) had detectable concentrations of plasma p,p´-DDE, but only 10.0% had detectable p,p´-DDT. Participants with detectable p,p´-DDT had significantly lower mean FVC (difference = 311 mL; 95% CI: –492, –130; p = 0.003) and FEV1 (difference = 232 mL; 95% CI: –408, –55; p = 0.015) than those without. A 100-ng/g lipid increase in plasma p,p´-DDE was associated with an 18.8-mL decrease in mean FVC (95% CI: –29, –9) and an 11.8-mL decrease in mean FEV1 (95% CI: –21, –3). Neither exposure was associated with FEV1/FVC ratio or FEF25%–75%. Conclusions DDT exposures, which may have occurred decades ago, were still detectable among Canadians. Plasma DDT and DDE were negatively associated with lung function parameters. Additional research on the potential effects of DDT use on lung function is warranted. Citation Ye M, Beach J, Martin JW, Senthilselvan A. 2015. Association between lung function in adults and plasma DDT and DDE levels: results from the Canadian Health Measures Survey. Environ Health Perspect 123:422–427; http://dx.doi.org/10.1289/ehp.1408217 PMID:25536373

  9. Prognostic value of serum zinc levels in patients with acute HC/zinc chloride smoke inhalation

    PubMed Central

    Xie, Fei; Zhang, Xingang; Xie, Lixin

    2017-01-01

    Abstract Hexachloroethane (HC)/zinc chloride (ZnCl, smoke bomb) exposure in the military setting results in lung injury which is uncommon and has been rarely described in previous studies. The aim of this study is to investigate the correlation between the serum zinc in patients with HC/ZnCl smoke inhalation lung injury and disease severity. A total of 15 patients with HC/ZnCl-related conditions were recruited in this study. The serum zinc level and the pulmonary function tests and liver function tests including total lung capacity (TLC), forced vital capacity (FVC), forced expiratory pressure in 1 second (FEV1), alanine aminotransferase (ALT), and aspartate transaminase (AST) were analyzed. Eleven cases had mild clinical manifestations. Four cases rapidly developed features typical of severe adult respiratory distress syndrome. The level of serum zinc was increased, but FVC, FEV1, and TLC was decreased significantly in the moderate and severe cases. In addition, the serum zinc level correlated well with the TLC, FVC, and FEV1 (r = −0.587, −0.626, −0.617, respectively; P = .027, .017, .019, respectively). The 4 cases in moderate and severe group had delayed impairment of liver functions after the accident. This study suggested that the serum zinc level may be associated with the severity of lung and liver injuries after HC/ZnCl smoke inhalation. PMID:28953660

  10. Lung function, respiratory symptoms and venous thromboembolism risk: the Atherosclerosis Risk in Communities Study.

    PubMed

    Kubota, Y; London, S J; Cushman, M; Chamberlain, A M; Rosamond, W D; Heckbert, S R; Zakai, N; Folsom, A R

    2016-12-01

    Essentials The association of lung function with venous thromboembolism (VTE) is unclear. Chronic obstructive pulmonary disease (COPD) patterns were associated with a higher risk of VTE. Symptoms were also associated with a higher risk of VTE, but a restrictive pattern was not. COPD may increase the risk of VTE and respiratory symptoms may be a novel risk marker for VTE. Background The evidence for the association between chronic obstructive pulmonary disease (COPD) and venous thromboembolism (VTE) is limited. There is no study investigating the association between restrictive lung disease (RLD) and respiratory symptoms with VTE. Objectives To investigate prospectively the association of lung function and respiratory symptoms with VTE. Patients/Methods In 1987-1989, we assessed lung function by using spirometry, and obtained information on respiratory symptoms (cough, phlegm, and dyspnea) in 14 654 participants aged 45-64 years, without a history of VTE or anticoagulant use, and followed them through 2011. Participants were classified into four mutually exclusive groups: 'COPD' (forced expiratory volume in 1 s [FEV 1 ]/forced vital capacity [FVC] below the lower limit of normal [LLN]), 'RLD' (FEV 1 /FVC ≥ LLN and FVC < LLN), 'respiratory symptoms with normal spirometic results' (without RLD or COPD), and 'normal' (without respiratory symptoms, RLD, or COPD). Results We documented 639 VTEs (238 unprovoked and 401 provoked VTEs). After adjustment for VTE risk factors, VTE risk was increased for individuals with either respiratory symptoms with normal spirometric results (hazard ratio [HR] 1.40, 95% confidence interval [CI] 1.12-1.73) or COPD (HR 1.33, 95% CI 1.07-1.67) but not for those with RLD (HR 1.15, 95% CI 0.82-1.60). These elevated risks of VTE were derived from both unprovoked and provoked VTE. Moreover, FEV 1 and FEV 1 /FVC showed dose-response relationships with VTE. COPD was more strongly associated with pulmonary embolism than with deep vein thrombosis. Conclusions Obstructive spirometric patterns were associated with an increased risk of VTE, suggesting that COPD may increase the risk of VTE. Respiratory symptoms may represent a novel risk marker for VTE. © 2016 International Society on Thrombosis and Haemostasis.

  11. Respiratory symptoms and lung function in alumina refinery employees.

    PubMed

    Musk, A W; de Klerk, N H; Beach, J R; Fritschi, L; Sim, M R; Benke, G; Abramson, M; McNeil, J J

    2000-04-01

    Employees in alumina refineries are known to be exposed to a number of potential respiratory irritants, particularly caustic mist and bauxite and alumina dusts. To examine the prevalence of work related respiratory symptoms and lung function in alumina refinery employees and relate these to their jobs. 2964 current employees of three alumina refineries in Western Australia were invited to participate in a cross sectional study, and 89% responded. Subjects were given a questionnaire on respiratory symptoms, smoking, and occupations with additional questions on temporal relations between respiratory symptoms and work. Forced expiratory volume in 1 second (FEV(1)) and forced vital capacity (FVC) were measured with a rolling seal spirometer. Atopy was assessed with prick skin tests for common allergens. Associations between work and symptoms were assessed with Cox's regression to estimate prevalence ratios, and between work and lung function with linear regression. Work related wheeze, chest tightness, shortness of breath, and rhinitis were reported by 5.0%, 3.5%, 2.5%, and 9.5% of participants respectively. After adjustment for age, smoking, and atopy, most groups of production employees reported a greater prevalence of work related symptoms than did office employees. After adjustment for age, smoking, height, and atopy, subjects reporting work related wheeze, chest tightness, and shortness of breath had significantly lower mean levels of FEV(1) (186, 162, and 272 ml respectively) than subjects without these symptoms. Prevalence of most work related symptoms was higher at refinery 2 than at the other two refineries, but subjects at this refinery had an adjusted mean FEV(1) >60 ml higher than the others. Significant differences in FVC and FEV(1)/FVC ratio, but not FEV(1), were found between different process groups. There were significant differences in work related symptoms and lung function between process groups and refineries, but these were mostly not consistent. Undefined selection factors and underlying population differences may account for some of these findings but workplace exposures may also contribute. The differences identified between groups were unlikely to be clinically of note.

  12. Respiratory symptoms and lung function in alumina refinery employees

    PubMed Central

    Musk, A; de Klerk, N. H; Beach, J.; Fritschi, L.; Sim, M.; Benke, G.; Abramson, M.; McNeil, J.

    2000-01-01

    OBJECTIVES—Employees in alumina refineries are known to be exposed to a number of potential respiratory irritants, particularly caustic mist and bauxite and alumina dusts. To examine the prevalence of work related respiratory symptoms and lung function in alumina refinery employees and relate these to their jobs.
METHODS—2964 current employees of three alumina refineries in Western Australia were invited to participate in a cross sectional study, and 89% responded. Subjects were given a questionnaire on respiratory symptoms, smoking, and occupations with additional questions on temporal relations between respiratory symptoms and work. Forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) were measured with a rolling seal spirometer. Atopy was assessed with prick skin tests for common allergens. Associations between work and symptoms were assessed with Cox's regression to estimate prevalence ratios, and between work and lung function with linear regression.
RESULTS—Work related wheeze, chest tightness, shortness of breath, and rhinitis were reported by 5.0%, 3.5%, 2.5%, and 9.5% of participants respectively. After adjustment for age, smoking, and atopy, most groups of production employees reported a greater prevalence of work related symptoms than did office employees. After adjustment for age, smoking, height, and atopy, subjects reporting work related wheeze, chest tightness, and shortness of breath had significantly lower mean levels of FEV1 (186, 162, and 272 ml respectively) than subjects without these symptoms. Prevalence of most work related symptoms was higher at refinery 2 than at the other two refineries, but subjects at this refinery had an adjusted mean FEV1 >60 ml higher than the others. Significant differences in FVC and FEV1/FVC ratio, but not FEV1, were found between different process groups.
CONCLUSIONS—There were significant differences in work related symptoms and lung function between process groups and refineries, but these were mostly not consistent. Undefined selection factors and underlying population differences may account for some of these findings but workplace exposures may also contribute. The differences identified between groups were unlikely to be clinically of note.


Keywords: aluminium; alumina; bauxite; caustic mist; occupational epidemiology PMID:10810116

  13. Evidence for a Cystic Fibrosis Enteropathy

    PubMed Central

    Adriaanse, Marlou P. M.; van der Sande, Linda J. T. M.; van den Neucker, Anita M.; Menheere, Paul P. C. A.; Dompeling, Edward; Buurman, Wim A.; Vreugdenhil, Anita C. E.

    2015-01-01

    Background Previous studies have suggested the existence of enteropathy in cystic fibrosis (CF), which may contribute to intestinal function impairment, a poor nutritional status and decline in lung function. This study evaluated enterocyte damage and intestinal inflammation in CF and studied its associations with nutritional status, CF-related morbidities such as impaired lung function and diabetes, and medication use. Methods Sixty-eight CF patients and 107 controls were studied. Levels of serum intestinal-fatty acid binding protein (I-FABP), a specific marker for enterocyte damage, were retrospectively determined. The faecal intestinal inflammation marker calprotectin was prospectively studied. Nutritional status, lung function (FEV1), exocrine pancreatic insufficiency (EPI), CF-related diabetes (CFRD) and use of proton pump inhibitors (PPI) were obtained from the medical charts. Results Serum I-FABP levels were elevated in CF patients as compared with controls (p<0.001), and correlated negatively with FEV1 predicted value in children (r-.734, p<0.05). Faecal calprotectin level was elevated in 93% of CF patients, and correlated negatively with FEV1 predicted value in adults (r-.484, p<0.05). No correlation was found between calprotectin levels in faeces and sputum. Faecal calprotectin level was significantly associated with the presence of CFRD, EPI, and PPI use. Conclusion This study demonstrated enterocyte damage and intestinal inflammation in CF patients, and provides evidence for an inverse correlation between enteropathy and lung function. The presented associations of enteropathy with important CF-related morbidities further emphasize the clinical relevance. PMID:26484665

  14. Risk factors for lung function decline in a large cohort of young cystic fibrosis patients.

    PubMed

    Cogen, Jonathan; Emerson, Julia; Sanders, Don B; Ren, Clement; Schechter, Michael S; Gibson, Ronald L; Morgan, Wayne; Rosenfeld, Margaret

    2015-08-01

    To identify novel risk factors and corroborate previously identified risk factors for mean annual decline in FEV1% predicted in a large, contemporary, United States cohort of young cystic fibrosis (CF) patients. Retrospective observational study of participants in the EPIC Observational Study, who were Pseudomonas-negative and ≤12 years of age at enrollment in 2004-2006. The associations between potential demographic, clinical, and environmental risk factors evaluated during the baseline year and subsequent mean annual decline in FEV1 percent predicted were evaluated using generalized estimating equations. The 946 participants in the current analysis were followed for a mean of 6.2 (SD 1.3) years. Mean annual decline in FEV1% predicted was 1.01% (95%CI 0.85-1.17%). Children with one or no F508del mutations had a significantly smaller annual decline in FEV1 compared to F508del homozygotes. In a multivariable model, risk factors during the baseline year associated with a larger subsequent mean annual lung function decline included female gender, frequent or productive cough, low BMI (<66th percentile, median in the cohort), ≥1 pulmonary exacerbation, high FEV1 (≥115% predicted, in the top quartile), and respiratory culture positive for methicillin-sensitive Staphylococcus aureus, methicillin-resistant S. aureus, or Stenotrophomonas maltophilia. We have identified a range of risk factors for FEV1 decline in a large cohort of young, CF patients who were Pa negative at enrollment, including novel as well as previously identified characteristics. These results could inform the design of a clinical trial in which rate of FEV1 decline is the primary endpoint and identify high-risk groups that may benefit from closer monitoring. © 2015 Wiley Periodicals, Inc.

  15. Associations between Dietary Patterns and Post-Bronchodilation Lung Function in the SAPALDIA Cohort.

    PubMed

    Steinemann, Nina; Grize, Leticia; Pons, Marco; Rothe, Thomas; Stolz, Daiana; Turk, Alexander; Schindler, Christian; Brombach, Christine; Probst-Hensch, Nicole

    2018-05-04

    Chronic obstructive pulmonary disease (COPD) is not restricted to smokers. Dietary habits may contribute to the disease occurrence. Epidemiological studies point to a protective effect of fruit and vegetable intake against COPD. To investigate the associations between dietary patterns and parameters of lung function related to COPD in the Swiss Cohort Study on Air Pollution and Lung and Heart Diseases in Adults (SAPALDIA). Data were included from the second follow-up assessment of the SAPALDIA cohort in 2010-2011 using a food frequency questionnaire. Principal component factor analysis was used to derive dietary patterns, whose association with FEV1, FEV1/FVC, FEF2575, and COPD was investigated by applying multivariate regression analyses. After adjustment for potential confounders, the "prudent dietary pattern" characterised by the predominant food groups vegetables, fruits, water, tea and coffee, fish, and nuts was positively associated with FEV1 (increase of 40 mL per SD, p < 0.001). Also for factor 3 ("high-carbohydrate diet"), we found a significant positive association with FEV1 (with an increase per SD of 36 mL, p = 0.006). The main results are consistent with a protective effect of a diet rich in fruits, vegetables, fish, and nuts against age-related chronic respiratory disease. If confirmed in prospective cohorts, our results may guide nutritional counselling towards respiratory health promotion. © 2018 The Author(s) Published by S. Karger AG, Basel.

  16. Pulmonary function tests

    MedlinePlus

    ... exhale, and how quickly you exhale, spirometry can evaluate a broad range of lung diseases. In a ... expiratory volume in 1 second (FEV1) Forced expiratory flow 25% to 75% (FEF25-75) Functional residual capacity ( ...

  17. Genome-wide interaction study of dust mite allergen on lung function in children with asthma.

    PubMed

    Forno, Erick; Sordillo, Joanne; Brehm, John; Chen, Wei; Benos, Takis; Yan, Qi; Avila, Lydiana; Soto-Quirós, Manuel; Cloutier, Michelle M; Colón-Semidey, Angel; Alvarez, Maria; Acosta-Pérez, Edna; Weiss, Scott T; Litonjua, Augusto A; Canino, Glorisa; Celedón, Juan C

    2017-10-01

    Childhood asthma is likely the result of gene-by-environment (G × E) interactions. Dust mite is a known risk factor for asthma morbidity. Yet, there have been no genome-wide G × E studies of dust mite allergen on asthma-related phenotypes. We sought to identify genetic variants whose effects on lung function in children with asthma are modified by the level of dust mite allergen exposure. A genome-wide interaction analysis of dust mite allergen level and lung function was performed in a cohort of Puerto Rican children with asthma (Puerto Rico Genetics of Asthma and Lifestyle [PRGOAL]). Replication was attempted in 2 independent cohorts, the Childhood Asthma Management Program (CAMP) and the Genetics of Asthma in Costa Rica Study. Single nucleotide polymorphism (SNP) rs117902240 showed a significant interaction effect on FEV 1 with dust mite allergen level in PRGOAL (interaction P = 3.1 × 10 -8 ), and replicated in the same direction in CAMP white children and CAMP Hispanic children (combined interaction P = .0065 for replication cohorts and 7.4 × 10 -9 for all cohorts). Rs117902240 was positively associated with FEV 1 in children exposed to low dust mite allergen levels, but negatively associated with FEV 1 in children exposed to high levels. This SNP is on chromosome 8q24, adjacent to a binding site for CCAAT/enhancer-binding protein beta, a transcription factor that forms part of the IL-17 signaling pathway. None of the SNPs identified for FEV 1 /forced vital capacity replicated in the independent cohorts. Dust mite allergen exposure modifies the estimated effect of rs117902240 on FEV 1 in children with asthma. Analysis of existing data suggests that this SNP may have transcription factor regulatory functions. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  18. Decline in lung function among cement production workers: a meta-analysis.

    PubMed

    Moghadam, Somayeh Rahimi; Abedi, Siavosh; Afshari, Mahdi; Abedini, Ehsan; Moosazadeh, Mahmood

    2017-12-20

    Several studies with different results have been performed regarding cement dust exposure and its pathogenic outcomes during the previous years. This study aims to combine these results to obtain a reliable estimate of the effect of exposure to cement dust. PubMed and other data banks were searched to identify required electronic articles. The search was extended interviewing with relevant experts and research centers. Point and pooled estimates of outcome with 95% confidence intervals were estimated. Participants were 5371 exposed and 2650 unexposed persons. Total mean differences (95% confidence intervals) were estimated as of -0.48 (-0.71 to -0.25) L for forced vital capacity (FVC), -0.7 (-0.92 to -0.47) L for forced expiratory volume in the first second (FEV1), -0.43 (-0.68 to -0.19) L for FEV1/FVC%, -0.73 (-1.15 to -0.30) L/min for PEFR and -0.36 (-0.51 to -0.21) L/s for FEF25-75. Our meta-analysis showed that cement dust has significant impact on lung function and reduces the indicators of FVC, FEV1, FEV1/FVC, PEFR and FEF25-75.

  19. Genome-wide association and large scale follow-up identifies 16 new loci influencing lung function

    PubMed Central

    Artigas, María Soler; Loth, Daan W; Wain, Louise V; Gharib, Sina A; Obeidat, Ma’en; Tang, Wenbo; Zhai, Guangju; Zhao, Jing Hua; Smith, Albert Vernon; Huffman, Jennifer E; Albrecht, Eva; Jackson, Catherine M; Evans, David M; Cadby, Gemma; Fornage, Myriam; Manichaikul, Ani; Lopez, Lorna M; Johnson, Toby; Aldrich, Melinda C; Aspelund, Thor; Barroso, Inês; Campbell, Harry; Cassano, Patricia A; Couper, David J; Eiriksdottir, Gudny; Franceschini, Nora; Garcia, Melissa; Gieger, Christian; Gislason, Gauti Kjartan; Grkovic, Ivica; Hammond, Christopher J; Hancock, Dana B; Harris, Tamara B; Ramasamy, Adaikalavan; Heckbert, Susan R; Heliövaara, Markku; Homuth, Georg; Hysi, Pirro G; James, Alan L; Jankovic, Stipan; Joubert, Bonnie R; Karrasch, Stefan; Klopp, Norman; Koch, Beate; Kritchevsky, Stephen B; Launer, Lenore J; Liu, Yongmei; Loehr, Laura R; Lohman, Kurt; Loos, Ruth JF; Lumley, Thomas; Al Balushi, Khalid A; Ang, Wei Q; Barr, R Graham; Beilby, John; Blakey, John D; Boban, Mladen; Boraska, Vesna; Brisman, Jonas; Britton, John R; Brusselle, Guy G; Cooper, Cyrus; Curjuric, Ivan; Dahgam, Santosh; Deary, Ian J; Ebrahim, Shah; Eijgelsheim, Mark; Francks, Clyde; Gaysina, Darya; Granell, Raquel; Gu, Xiangjun; Hankinson, John L; Hardy, Rebecca; Harris, Sarah E; Henderson, John; Henry, Amanda; Hingorani, Aroon D; Hofman, Albert; Holt, Patrick G; Hui, Jennie; Hunter, Michael L; Imboden, Medea; Jameson, Karen A; Kerr, Shona M; Kolcic, Ivana; Kronenberg, Florian; Liu, Jason Z; Marchini, Jonathan; McKeever, Tricia; Morris, Andrew D; Olin, Anna-Carin; Porteous, David J; Postma, Dirkje S; Rich, Stephen S; Ring, Susan M; Rivadeneira, Fernando; Rochat, Thierry; Sayer, Avan Aihie; Sayers, Ian; Sly, Peter D; Smith, George Davey; Sood, Akshay; Starr, John M; Uitterlinden, André G; Vonk, Judith M; Wannamethee, S Goya; Whincup, Peter H; Wijmenga, Cisca; Williams, O Dale; Wong, Andrew; Mangino, Massimo; Marciante, Kristin D; McArdle, Wendy L; Meibohm, Bernd; Morrison, Alanna C; North, Kari E; Omenaas, Ernst; Palmer, Lyle J; Pietiläinen, Kirsi H; Pin, Isabelle; Polašek, Ozren; Pouta, Anneli; Psaty, Bruce M; Hartikainen, Anna-Liisa; Rantanen, Taina; Ripatti, Samuli; Rotter, Jerome I; Rudan, Igor; Rudnicka, Alicja R; Schulz, Holger; Shin, So-Youn; Spector, Tim D; Surakka, Ida; Vitart, Veronique; Völzke, Henry; Wareham, Nicholas J; Warrington, Nicole M; Wichmann, H-Erich; Wild, Sarah H; Wilk, Jemma B; Wjst, Matthias; Wright, Alan F; Zgaga, Lina; Zemunik, Tatijana; Pennell, Craig E; Nyberg, Fredrik; Kuh, Diana; Holloway, John W; Boezen, H Marike; Lawlor, Debbie A; Morris, Richard W; Probst-Hensch, Nicole; Kaprio, Jaakko; Wilson, James F; Hayward, Caroline; Kähönen, Mika; Heinrich, Joachim; Musk, Arthur W; Jarvis, Deborah L; Gläser, Sven; Järvelin, Marjo-Riitta; Stricker, Bruno H Ch; Elliott, Paul; O’Connor, George T; Strachan, David P; London, Stephanie J; Hall, Ian P; Gudnason, Vilmundur; Tobin, Martin D

    2011-01-01

    Pulmonary function measures reflect respiratory health and predict mortality, and are used in the diagnosis of chronic obstructive pulmonary disease (COPD). We tested genome-wide association with the forced expiratory volume in 1 second (FEV1) and the ratio of FEV1 to forced vital capacity (FVC) in 48,201 individuals of European ancestry, with follow-up of top associations in up to an additional 46,411 individuals. We identified new regions showing association (combined P<5×10−8) with pulmonary function, in or near MFAP2, TGFB2, HDAC4, RARB, MECOM (EVI1), SPATA9, ARMC2, NCR3, ZKSCAN3, CDC123, C10orf11, LRP1, CCDC38, MMP15, CFDP1, and KCNE2. Identification of these 16 new loci may provide insight into the molecular mechanisms regulating pulmonary function and into molecular targets for future therapy to alleviate reduced lung function. PMID:21946350

  20. Decreased lung function with mediation of blood parameters linked to e-waste lead and cadmium exposure in preschool children.

    PubMed

    Zeng, Xiang; Xu, Xijin; Boezen, H Marike; Vonk, Judith M; Wu, Weidong; Huo, Xia

    2017-11-01

    Blood lead (Pb) and cadmium (Cd) levels have been associated with lower lung function in adults and smokers, but whether this also holds for children from electronic waste (e-waste) recycling areas is still unknown. To investigate the contribution of blood heavy metals and lung function levels, and the relationship among living area, the blood parameter levels, and the lung function levels, a total of 206 preschool children from Guiyu (exposed area), and Haojiang and Xiashan (reference areas) were recruited and required to undergo blood tests and lung function tests during the study period. Preschool children living in e-waste exposed areas were found to have a 1.37 μg/dL increase in blood Pb, 1.18 μg/L increase in blood Cd, and a 41.00 × 10 9 /L increase in platelet counts, while having a 2.82 g/L decrease in hemoglobin, 92 mL decrease in FVC and 86 mL decrease in FEV 1 . Each unit of hemoglobin (1 g/L) decline was associated with 5 mL decrease in FVC and 4 mL decrease in FEV 1 . We conclude that children living in e-waste exposed area have higher levels of blood Pb, Cd and platelets, and lower levels of hemoglobin and lung function. Hemoglobin can be a good predictor for lung function levels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Usefulness of inspiratory capacity measurement in COPD patients in the primary care setting

    PubMed Central

    Madueño, Antonio; Martín, Antonio; Péculo, Juan-Antonio; Antón, Esther; Paravisini, Alejandra; León, Antonio

    2009-01-01

    Objective: To determine if inspiratory capacity (IC) assessment could be useful for chronic obstructive pulmonary disease (COPD) patient management in the primary care setting. Methods: A descriptive cross-sectional study was conducted in 93 patients diagnosed with COPD according to Spanish Thoracic Society (SEPAR) criteria. Patients were recruited in eight primary care centers in Andalusia, Spain. Anthropometric, sociodemographic, resting lung function (forced expiratory volume in one second [FEV1], forced vital capacity, synchronized vital capacity, IC), and quality of life data based on the Spanish version of Saint George’s Respiratory Questionnaire (SGRQ) were obtained. Results: Lung function results expressed as percentages of the predicted values were as follows: FEV1, 49.04 (standard deviation [SD]: 16.23); IC, 61.73 (SD: 15.42). The SGRQ mean total score was 47.5 (SD 17.98). The Spearman’s Rho correlation between FEV1 and SGRQ was r = −0.36 (95% confidence interval [CI]: −0.529 to −0.166), between IC and SGRQ was r = −0.329 (95% CI −0.502 to −0.131), and between FEV1 and IC was r = −0.561. Conclusions: Measurement of IC at rest could be used as a complementary functional exploration to forced spirometry in the monitorization of patients with COPD in the primary care setting. We found a poor correlation between IC and quality of life at the same level as in FEV1. PMID:20360907

  2. Arsenic Exposure and Impaired Lung Function. Findings from a Large Population-based Prospective Cohort Study

    PubMed Central

    Parvez, Faruque; Chen, Yu; Yunus, Mahbub; Olopade, Christopher; Segers, Stephanie; Slavkovich, Vesna; Argos, Maria; Hasan, Rabiul; Ahmed, Alauddin; Islam, Tariqul; Akter, Mahmud M.; Graziano, Joseph H.

    2013-01-01

    Rationale: Exposure to arsenic through drinking water has been linked to respiratory symptoms, obstructive lung diseases, and mortality from respiratory diseases. Limited evidence for the deleterious effects on lung function exists among individuals exposed to a high dose of arsenic. Objectives: To determine the deleterious effects on lung function that exist among individuals exposed to a high dose of arsenic. Methods: In 950 individuals who presented with any respiratory symptom among a population-based cohort of 20,033 adults, we evaluated the association between arsenic exposure, measured by well water and urinary arsenic concentrations measured at baseline, and post-bronchodilator–administered pulmonary function assessed during follow-up. Measurements and Main Results: For every one SD increase in baseline water arsenic exposure, we observed a lower level of FEV1 (−46.5 ml; P < 0.0005) and FVC (−53.1 ml; P < 0.01) in regression models adjusted for age, sex, body mass index, smoking, socioeconomic status, betel nut use, and arsenical skin lesions status. Similar inverse relationships were observed between baseline urinary arsenic and FEV1 (−48.3 ml; P < 0.005) and FVC (−55.2 ml; P < 0.01) in adjusted models. Our analyses also demonstrated a dose-related decrease in lung function with increasing levels of baseline water and urinary arsenic. This association remained significant in never-smokers and individuals without skin lesions, and was stronger in male smokers. Among male smokers and individuals with skin lesions, every one SD increase in water arsenic was related to a significant reduction of FEV1 (−74.4 ml, P < 0.01; and −116.1 ml, P < 0.05) and FVC (−72.8 ml, P = 0.02; and −146.9 ml, P = 0.004), respectively. Conclusions: This large population-based study confirms that arsenic exposure is associated with impaired lung function and the deleterious effect is evident at low- to moderate-dose range. PMID:23848239

  3. Favorable longitudinal change of lung function in patients with asthma-COPD overlap from a COPD cohort.

    PubMed

    Park, Hye Yun; Lee, Suh-Young; Kang, Danbee; Cho, Juhee; Lee, Hyun; Lim, Seong Yong; Yoon, Ho Il; Ra, Seung Won; Kim, Ki Uk; Oh, Yeon-Mok; Sin, Don D; Lee, Sang-Do; Park, Yong Bum

    2018-03-02

    The recognition of asthma-chronic obstructive pulmonary disease (COPD) overlap (ACO) as a distinct phenotype of COPD or asthma has increased. Although ACO has worse clinical features than non-ACO COPD, limited information is available on long-term outcomes of lung function decline for ACO and non-ACO COPD. COPD patients with at least 3 years of follow-up were selected from the Korean Obstructive Lung Disease cohort. ACO was defined based on 3 major criteria: 1) airflow limitation in individuals 40 years of age and older, 2) ≥10 pack-years of smoking history, and 3) a history of asthma or bronchodilator response of > 400 mL in forced expiratory volume in 1 s (FEV 1 ) at baseline; and at least 1 minor criterion: 1) history of atopy or allergic rhinitis, 2) two separated bronchodilator responses of ≥12% and 200 mL in FEV 1 , or 3) peripheral blood eosinophils ≥300 cells/μL. Lung function decline was compared using a linear mixed effects model for longitudinal data with random intercept and random slope. Among 239 patients, 47 were diagnosed with ACO (19.7%). During the follow-up period, change in smoking status, use of inhaled corticosteroids (ICS) and long-acting β2-agonists or ICS and at least 2 exacerbations per year were similar between patients with non-ACO COPD and ACO. Over a median follow-up duration of 5.8 years, patients with non-ACO COPD experienced a faster annual decline in pre-bronchodilator FEV 1 than patients with ACO (- 29.3 ml/year vs. -13.9 ml/year, P = 0.042), which was persistent after adjustment for confounders affecting lung function decline. Patients with ACO showed favorable longitudinal changes in lung function compared to COPD patients over a median follow-up of 5.8 years.

  4. Differential respirable dust related lung function effects between current and former South African coal miners.

    PubMed

    Naidoo, Rajen N; Robins, Thomas G; Seixas, Noah; Lalloo, Umesh G; Becklake, Margaret

    2005-05-01

    Dust-related dose-response decrements in lung function among coal miners have been reported in several studies, with varying magnitudes across populations. Few studies have compared differences between current and former coal miners. No studies on dose response relationships with lung function have been conducted in South African coal mines, one of the top three producers of coal internationally. The objectives of this study were (1) to describe the relationship between respirable dust exposure and lung function among current and former South African coal miners and to determine whether differential dust related effects were present between these employment categories; (2) to examine dust related dose response relationships, controlling for potential confounding by smoking and a history of tuberculosis (TB). Six hundred and eighty-four current and 188 ex-miners from three bituminous coal mines in Mpumalanga Province were studied. Interviews assessing work histories, smoking profiles and other risk factors were conducted. Work histories were also obtained from company records. Standardised spirometry was performed by trained technicians. Cumulative respirable dust exposure (CDE) estimates were constructed from company-collected sampling and measurements conducted by the researchers. Regression models examined the associations of CDE with per cent predicted FEV(1) and FVC, controlling for smoking, past history of TB and employment status. A statistically significant decline in FEV(1) of 1.1 and 2.2 ml/mg-year/m(3) was found in representative 40-year-old, 1.7-m tall current and former miners, respectively. Significant differences were found between the highest and medium exposure categories. Ex-miners had a lower mean per cent predicted lung function than current miners for each cumulative exposure category, suggesting a "healthy worker" effect. Past history of TB contributed to 21 and 14% declines in per cent predicted FEV(1) and FVC, respectively. Thus, in this cohort, a dose-related decline in lung function was associated with respirable dust exposure, with a magnitude of effect similar to that seen in other studies and important differences between current and former employees. A "healthy worker" effect may have attenuated the magnitude of this relationship. TB was a significant contributor to lung function loss.

  5. Genetic association between human chitinases and lung function in COPD.

    PubMed

    Aminuddin, F; Akhabir, L; Stefanowicz, D; Paré, P D; Connett, J E; Anthonisen, N R; Fahy, J V; Seibold, M A; Burchard, E G; Eng, C; Gulsvik, A; Bakke, P; Cho, M H; Litonjua, A; Lomas, D A; Anderson, W H; Beaty, T H; Crapo, J D; Silverman, E K; Sandford, A J

    2012-07-01

    Two primary chitinases have been identified in humans--acid mammalian chitinase (AMCase) and chitotriosidase (CHIT1). Mammalian chitinases have been observed to affect the host's immune response. The aim of this study was to test for association between genetic variation in the chitinases and phenotypes related to chronic obstructive pulmonary disease (COPD). Polymorphisms in the chitinase genes were selected based on previous associations with respiratory diseases. Polymorphisms that were associated with lung function level or rate of decline in the Lung Health Study (LHS) cohort were analyzed for association with COPD affection status in four other COPD case-control populations. Chitinase activity and protein levels were also related to genotypes. In the caucasian LHS population, the baseline forced expiratory volume in one second (FEV(1)) was significantly different between the AA and GG genotypic groups of the AMCase rs3818822 polymorphism. Subjects with the GG genotype had higher AMCase protein and chitinase activity compared with AA homozygotes. For CHIT1 rs2494303, a significant association was observed between rate of decline in FEV(1) and the different genotypes. In the African American LHS population, CHIT1 rs2494303 and AMCase G339T genotypes were associated with rate of decline in FEV(1). Although a significant effect of chitinase gene alleles was found on lung function level and decline in the LHS, we were unable to replicate the associations with COPD affection status in the other COPD study groups.

  6. Dynamic hyperinflation after metronome-paced hyperventilation in COPD--a 2 year follow-up.

    PubMed

    Hannink, Jorien; Lahaije, Anke; Bischoff, Erik; van Helvoort, Hanneke; Dekhuijzen, Richard; Schermer, Tjard; Heijdra, Yvonne

    2010-11-01

    In contrast to the decline in FEV(1), the behavior of dynamic hyperinflation (DH) over time is unknown in patients with COPD. Metronome-paced hyperventilation (MPH) is a simple applicable surrogate for exercise to detect DH. To evaluate changes in MPH-induced DH during two years follow-up in mild-to-severe COPD patients. Additionally, influence of smoking status on DH and the relation between DH and other lung function parameters were assessed. Patients were recruited from a randomized controlled trial conducted in general practice. Measurements of lung function and DH were performed at baseline and after 12 and 24 months. DH was assessed by MPH with breathing frequency set at twice the baseline rate. Change in inspiratory capacity after MPH was used to reflect change in end-expiratory lung volume and therefore DH, presuming constant total lung capacity. During follow-up, 68 patients completed all measurements. DH increased by 0.23±0.06L (p≤0.001). No significant changes in FEV(1) %pred were seen. Smokers had lower FEV(1) and a more rapid decline than non-smokers. DH in smokers increased more over time compared to non-smokers. The amount of DH correlated positively with resting inspiratory capacity. After two years, a significant increase in MPH-induced DH in COPD patients was demonstrated, which was not accompanied by a decline in FEV(1). It might be that DH is a sensitive measure to track consequences of changes in airflow obstruction. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. CT densitovolumetry in children with obliterative bronchiolitis: correlation with clinical scores and pulmonary function test results*,**

    PubMed Central

    Mocelin, Helena; Bueno, Gilberto; Irion, Klaus; Marchiori, Edson; Sarria, Edgar; Watte, Guilherme; Hochhegger, Bruno

    2013-01-01

    OBJECTIVE: To determine whether air trapping (expressed as the percentage of air trapping relative to total lung volume [AT%]) correlates with clinical and functional parameters in children with obliterative bronchiolitis (OB). METHODS: CT scans of 19 children with OB were post-processed for AT% quantification with the use of a fixed threshold of −950 HU (AT%950) and of thresholds selected with the aid of density masks (AT%DM). Patients were divided into three groups by AT% severity. We examined AT% correlations with oxygen saturation (SO2) at rest, six-minute walk distance (6MWD), minimum SO2 during the six-minute walk test (6MWT_SO2), FVC, FEV1, FEV1/FVC, and clinical parameters. RESULTS: The 6MWD was longer in the patients with larger normal lung volumes (r = 0.53). We found that AT%950 showed significant correlations (before and after the exclusion of outliers, respectively) with the clinical score (r = 0.72; 0.80), FVC (r = 0.24; 0.59), FEV1 (r = −0.58; −0.67), and FEV1/FVC (r = −0.53; r = −0.62), as did AT%DM with the clinical score (r = 0.58; r = 0.63), SO2 at rest (r = −0.40; r = −0.61), 6MWT_SO2 (r = −0.24; r = −0.55), FVC (r = −0.44; r = −0.80), FEV1 (r = −0.65; r = −0.71), and FEV1/FVC (r = −0.41; r = −0.52). CONCLUSIONS: Our results show that AT% correlates significantly with clinical scores and pulmonary function test results in children with OB. PMID:24473764

  8. Bronchodilator efficacy of tiotropium in patients with mild to moderate COPD.

    PubMed

    Johansson, Gunnar; Lindberg, Anne; Romberg, Kerstin; Nordström, Lars; Gerken, Fronke; Roquet, Annika

    2008-09-01

    Evaluation of tiotropium efficacy in patients with mild chronic obstructive pulmonary disease (COPD) defined by the 2003 Swedish Society of Respiratory Medicine guidelines (post-bronchodilator FEV1/FVC <70%; FEV1 >60% predicted). In this 12-week, randomised, double-blind, placebo-controlled study of tiotropium 18 mcg once daily versus placebo, respiratory function was assessed on Days 1, 15 and 85 (baseline: pre-dose Day 1). Mean+/-SD baseline FEV1 (% predicted) was 73.4+/-12.5 (tiotropium, n=107; placebo, n=117). Tiotropium significantly improved change from baseline in area under the curve from pre-dose to 2 hours post-dose (AUC0-2 h) FEV1 versus placebo, by 166+/-26 mL (mean+/-SE) at study end (p<0.0001). With tiotropium, there were significant increases in the change in AUC0-2 h FVC versus baseline, and trough FEV1 and FVC, versus placebo, on all test days (p<0.01). Adverse event rates were similar. Compared with placebo, tiotropium improved lung function in patients with mild COPD.

  9. Efficacy and safety of sirolimus in lymphangioleiomyomatosis.

    PubMed

    McCormack, Francis X; Inoue, Yoshikazu; Moss, Joel; Singer, Lianne G; Strange, Charlie; Nakata, Koh; Barker, Alan F; Chapman, Jeffrey T; Brantly, Mark L; Stocks, James M; Brown, Kevin K; Lynch, Joseph P; Goldberg, Hilary J; Young, Lisa R; Kinder, Brent W; Downey, Gregory P; Sullivan, Eugene J; Colby, Thomas V; McKay, Roy T; Cohen, Marsha M; Korbee, Leslie; Taveira-DaSilva, Angelo M; Lee, Hye-Seung; Krischer, Jeffrey P; Trapnell, Bruce C

    2011-04-28

    Lymphangioleiomyomatosis (LAM) is a progressive, cystic lung disease in women; it is associated with inappropriate activation of mammalian target of rapamycin (mTOR) signaling, which regulates cellular growth and lymphangiogenesis. Sirolimus (also called rapamycin) inhibits mTOR and has shown promise in phase 1-2 trials involving patients with LAM. We conducted a two-stage trial of sirolimus involving 89 patients with LAM who had moderate lung impairment--a 12-month randomized, double-blind comparison of sirolimus with placebo, followed by a 12-month observation period. The primary end point was the difference between the groups in the rate of change (slope) in forced expiratory volume in 1 second (FEV(1)). During the treatment period, the FEV(1) slope was -12±2 ml per month in the placebo group (43 patients) and 1±2 ml per month in the sirolimus group (46 patients) (P<0.001). The absolute between-group difference in the mean change in FEV(1) during the treatment period was 153 ml, or approximately 11% of the mean FEV(1) at enrollment. As compared with the placebo group, the sirolimus group had improvement from baseline to 12 months in measures of forced vital capacity, functional residual capacity, serum vascular endothelial growth factor D (VEGF-D), and quality of life and functional performance. There was no significant between-group difference in this interval in the change in 6-minute walk distance or diffusing capacity of the lung for carbon monoxide. After discontinuation of sirolimus, the decline in lung function resumed in the sirolimus group and paralleled that in the placebo group. Adverse events were more common with sirolimus, but the frequency of serious adverse events did not differ significantly between the groups. In patients with LAM, sirolimus stabilized lung function, reduced serum VEGF-D levels, and was associated with a reduction in symptoms and improvement in quality of life. Therapy with sirolimus may be useful in selected patients with LAM. (Funded by the National Institutes of Health and others; MILES ClinicalTrials.gov number, NCT00414648.).

  10. Efficacy and Safety of Sirolimus in Lymphangioleiomyomatosis

    PubMed Central

    McCormack, Francis X.; Inoue, Yoshikazu; Moss, Joel; Singer, Lianne G.; Strange, Charlie; Nakata, Koh; Barker, Alan F.; Chapman, Jeffrey T.; Brantly, Mark L.; Stocks, James M.; Brown, Kevin K.; Lynch, Joseph P.; Goldberg, Hilary J.; Young, Lisa R.; Kinder, Brent W.; Downey, Gregory P.; Sullivan, Eugene J.; Colby, Thomas V.; McKay, Roy T.; Cohen, Marsha M.; Korbee, Leslie; Taveira-DaSilva, Angelo M.; Lee, Hye-Seung; Krischer, Jeffrey P.; Trapnell, Bruce C.

    2011-01-01

    BACKGROUND Lymphangioleiomyomatosis (LAM) is a progressive, cystic lung disease in women; it is associated with inappropriate activation of mammalian target of rapamycin (mTOR) signaling, which regulates cellular growth and lymphangiogenesis. Sirolimus (also called rapamycin) inhibits mTOR and has shown promise in phase 1–2 trials involving patients with LAM. METHODS We conducted a two-stage trial of sirolimus involving 89 patients with LAM who had moderate lung impairment — a 12-month randomized, double-blind comparison of sirolimus with placebo, followed by a 12-month observation period. The primary end point was the difference between the groups in the rate of change (slope) in forced expiratory volume in 1 second (FEV1). RESULTS During the treatment period, the FEV1 slope was −12±2 ml per month in the placebo group (43 patients) and 1±2 ml per month in the sirolimus group (46 patients) (P<0.001). The absolute between-group difference in the mean change in FEV1 during the treatment period was 153 ml, or approximately 11% of the mean FEV1 at enrollment. As compared with the placebo group, the sirolimus group had improvement from baseline to 12 months in measures of forced vital capacity, functional residual capacity, serum vascular endothelial growth factor D (VEGF-D), and quality of life and functional performance. There was no significant between-group difference in this interval in the change in 6-minute walk distance or diffusing capacity of the lung for carbon monoxide. After discontinuation of sirolimus, the decline in lung function resumed in the sirolimus group and paralleled that in the placebo group. Adverse events were more common with sirolimus, but the frequency of serious adverse events did not differ significantly between the groups. CONCLUSIONS In patients with LAM, sirolimus stabilized lung function, reduced serum VEGF-D levels, and was associated with a reduction in symptoms and improvement in quality of life. Therapy with sirolimus may be useful in selected patients with LAM. (Funded by the National Institutes of Health and others; MILES ClinicalTrials.gov number, NCT00414648.) PMID:21410393

  11. Recovery of baseline lung function after pulmonary exacerbation in children with primary ciliary dyskinesia.

    PubMed

    Sunther, Meera; Bush, Andrew; Hogg, Claire; McCann, Lauren; Carr, Siobhán B

    2016-12-01

    Spirometry in children with cystic fibrosis (CF) frequently fails to return to baseline after treatment for a pulmonary exacerbation. It is unclear whether the same is true for children with primary ciliary dyskinesia (PCD). To determine in children with PCD treated with intravenous antibiotics for a pulmonary exacerbation: (1) the proportion who recover to baseline forced expiratory volume at 1 sec (FEV 1 ) within 3 months after treatment and (2) to try to identify factors which are associated with failure to regain pre-exacerbation FEV 1 . Cohort study using the PCD database for children at the Royal Brompton Hospital, 2003-2013. We selected the first pulmonary exacerbation treated with intravenous antibiotics. The best FEV 1 within 3 months after treatment was compared to the best FEV 1 in the 12 months before treatment (baseline). Recovery to baseline was defined as any FEV 1 after treatment that was greater than or equal to 90% of the baseline FEV 1 . 32/150 children (21%) had at least one pulmonary exacerbation. 23/30 (77%) regained baseline spirometry within 3 months of treatment. There was no difference between responders and non-responders in any baseline characteristics. Around 25% of children with PCD fail to recover to baseline lung function within 3 months following treatment for a pulmonary exacerbation, similar to CF. Better treatment strategies are needed, and the results also suggest that prevention of exacerbations would be a useful end-point in clinical trials. Pediatr Pulmonol. 2016;51:1362-1366. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Lysophosphatidic Acid and Apolipoprotein A1 Predict Increased Risk of Developing World Trade Center Lung Injury: A Nested Case-Control Study

    PubMed Central

    Tsukiji, Jun; Cho, Soo Jung; Echevarria, Ghislaine C.; Kwon, Sophia; Joseph, Phillip; Schenck, Edward J.; Naveed, Bushra; Prezant, David J.; Rom, William N.; Schmidt, Ann Marie; Weiden, Michael D.; Nolan, Anna

    2014-01-01

    Rationale Metabolic syndrome, inflammatory and vascular injury markers measured in serum after WTC exposures predict abnormal FEV1. We hypothesized that elevated LPA levels predict FEV1

  13. Parenchymal preserving anatomic resections result in less pulmonary function loss in patients with Stage I non-small cell lung cancer.

    PubMed

    Macke, Ryan A; Schuchert, Matthew J; Odell, David D; Wilson, David O; Luketich, James D; Landreneau, Rodney J

    2015-04-01

    A suggested benefit of sublobar resection for stage I non-small cell lung cancer (NSCLC) compared to lobectomy is a relative preservation of pulmonary function. Very little objective data exist, however, supporting this supposition. We sought to evaluate the relative impact of both anatomic segmental and lobar resection on pulmonary function in patients with resected clinical stage I NSCLC. The records of 159 disease-free patients who underwent anatomic segmentectomy (n = 89) and lobectomy (n = 70) for the treatment of stage I NSCLC with pre- and postoperative pulmonary function tests performed between 6 to 36 months after resection were retrospectively reviewed. Changes in forced expiratory volume in one second (FEV1) and diffusion capacity of carbon monoxide (DLCO) were analyzed based upon the number of anatomic pulmonary segments removed: 1-2 segments (n = 77) or 3-5 segments (n = 82). Preoperative pulmonary function was worse in the lesser resection cohort (1-2 segments) compared to the greater resection group (3-5 segments) (FEV1(%predicted): 79% vs. 85%, p = 0.038; DLCO(%predicted): 63% vs. 73%, p = 0.010). A greater decline in FEV1 was noted in patients undergoing resection of 3-5 segments (FEV1 (observed): 0.1 L vs. 0.3 L, p = 0.003; and FEV1 (% predicted): 4.3% vs. 8.2%, p = 0.055). Changes in DLCO followed this same trend (DLCO(observed): 1.3 vs. 2.4 mL/min/mmHg, p = 0.015; and DLCO(% predicted): 3.6% vs. 5.9%, p = 0.280). Parenchymal-sparing resections resulted in better preservation of pulmonary function at a median of one year, suggesting a long-term functional benefit with small anatomic segmental resections (1-2 segments). Prospective studies to evaluate measurable functional changes, as well as quality of life, between segmentectomy and lobectomy with a larger patient cohort appear justified.

  14. Design of the Endobronchial Valve for Emphysema Palliation Trial (VENT): a non-surgical method of lung volume reduction.

    PubMed

    Strange, Charlie; Herth, Felix J F; Kovitz, Kevin L; McLennan, Geoffrey; Ernst, Armin; Goldin, Jonathan; Noppen, Marc; Criner, Gerard J; Sciurba, Frank C

    2007-07-03

    Lung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently, less invasive bronchoscopic approaches have been designed to utilize these principles while avoiding the associated perioperative risks. The Endobronchial Valve for Emphysema PalliatioN Trial (VENT) posits that occlusion of a single pulmonary lobe through bronchoscopically placed Zephyr endobronchial valves will effect significant improvements in lung function and exercise tolerance with an acceptable risk profile in advanced emphysema. The trial design posted on Clinical trials.gov, on August 10, 2005 proposed an enrollment of 270 subjects. Inclusion criteria included: diagnosis of emphysema with forced expiratory volume in one second (FEV1) < 45% of predicted, hyperinflation (total lung capacity measured by body plethysmography > 100%; residual volume > 150% predicted), and heterogeneous emphysema defined using a quantitative chest computed tomography algorithm. Following standardized pulmonary rehabilitation, patients were randomized 2:1 to receive unilateral lobar placement of endobronchial valves plus optimal medical management or optimal medical management alone. The co-primary endpoint was the mean percent change in FEV1 and six minute walk distance at 180 days. Secondary end-points included mean percent change in St. George's Respiratory Questionnaire score and the mean absolute changes in the maximal work load measured by cycle ergometry, dyspnea (mMRC) score, and total oxygen use per day. Per patient response rates in clinically significant improvement/maintenance of FEV1 and six minute walk distance and technical success rates of valve placement were recorded. Apriori response predictors based on quantitative CT and lung physiology were defined. If endobronchial valves improve FEV1 and health status with an acceptable safety profile in advanced emphysema, they would offer a novel intervention for this progressive and debilitating disease. ClinicalTrials.gov: NCT00129584.

  15. Lung Function in Rescue Workers at the World Trade Center after 7 Years

    PubMed Central

    Aldrich, Thomas K.; Gustave, Jackson; Hall, Charles B.; Cohen, Hillel W.; Webber, Mayris P.; Zeig-Owens, Rachel; Cosenza, Kaitlyn; Christodoulou, Vasilios; Glass, Lara; Al-Othman, Fairouz; Weiden, Michael D.; Kelly, Kerry J.; Prezant, David J.

    2016-01-01

    Background The terrorist attacks on the World Trade Center on September 11, 2001, exposed thousands of Fire Department of New York City (FDNY) rescue workers to dust, leading to substantial declines in lung function in the first year. We sought to determine the longer-term effects of exposure. Methods Using linear mixed models, we analyzed the forced expiratory volume in 1 second (FEV1) of both active and retired FDNY rescue workers on the basis of spirometry routinely performed at intervals of 12 to 18 months from March 12, 2000, to September 11, 2008. Results Of the 13,954 FDNY workers who were present at the World Trade Center between September 11, 2001, and September 24, 2001, a total of 12,781 (91.6%) participated in this study, contributing 61,746 quality-screened spirometric measurements. The median follow-up was 6.1 years for firefighters and 6.4 years for emergency-medical-services (EMS) workers. In the first year, the mean FEV1 decreased significantly for all workers, more for firefighters who had never smoked (a reduction of 439 ml; 95% confidence interval [CI], 408 to 471) than for EMS workers who had never smoked (a reduction of 267 ml; 95% CI, 263 to 271) (P<0.001 for both comparisons). There was little or no recovery in FEV1 during the subsequent 6 years, with a mean annualized reduction in FEV1 of 25 ml per year for firefighters and 40 ml per year for EMS workers. The proportion of workers who had never smoked and who had an FEV1 below the lower limit of the normal range increased during the first year, from 3% to 18% for firefighters and from 12% to 22% for EMS workers, stabilizing at about 13% for firefighters and 22% for EMS workers during the subsequent 6 years. Conclusions Exposure to World Trade Center dust led to large declines in FEV1 for FDNY rescue workers during the first year. Overall, these declines were persistent, without recovery over the next 6 years, leaving a substantial proportion of workers with abnormal lung function. PMID:20375403

  16. Pulmonary Function Test Abnormalities in Children With Inflammatory Bowel Disease: Is It Common?

    PubMed

    El Amrousy, Doaa Mohamed; Hassan, Samir; El-Ashry, Heba; Yousef, Mohamed; Sharshar, Ragia

    2018-04-03

    The aim of the study was to evaluate the frequency and type of pulmonary dysfunction in newly diagnosed children with inflammatory bowel disease (IBD) and the correlation between pulmonary function tests (PFTs) and IBD activity. It is an observational case-control study. One hundred newly diagnosed children with IBD were enrolled as the patient group, which was subdivided into 52 with Crohn disease (CD) and 48 with ulcerative colitis (UC). Fifty healthy children matched for age, sex, height, and body mass index (BMI) served as the control group. PFTs in the form of forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), FEV1/FVC, residual volume (RV), total lung capacity (TLC), mid-forced expiratory flow of 25% to 75% (FEF 25%-75%) and diffusing capacity of the lung for carbon monoxide (DLCO) were evaluated in all studied children. PFTs were measured at diagnosis, every 6 months for a period of 3 years, during remission and at least once during activity in patient group. There was significant progressive deterioration in all PFTs in IBD patients compared with their PFTs at the start of the study (P < 0.05) except for FEV1/FVC, RV, and TLC (P > 0.05). There was significant deterioration during disease activity compared with remission state regarding FEV1, FVC, FEV 25% to 75%, and DLCO (P < 0.05). Significant negative correlation was found between disease activity in both UC and CD groups and FEV1, FVC, FEV 25% to 75%, and DLCO. Subclinical PFT abnormalities are common in pediatric IBD even during remission period. So, periodic PFT evaluation should be considered in the routine follow-up of IBD children.

  17. Determinants of lung function and airway hyperresponsiveness in asthmatic children.

    PubMed

    Bisgaard, H; Pedersen, S; Anhøj, J; Agertoft, L; Hedlin, G; Gulsvik, A; Bjermer, L; Carlsen, K H; Nordvall, L; Lundbäck, B; Wennergren, G; Werner, S; Bønnelykke, K; Weiss, S T

    2007-07-01

    Asthma patients exhibit an increased rate of loss of lung function. Determinants to such decline are largely unknown and the modifying effect of steroid therapy is disputed. This cross-sectional study aimed to elucidate factors contributing to such decline and the possible modifying effect of steroid treatment. We analyzed determinants of lung function and airway hyperresponsiveness (AHR) in a Scandinavian study of 2390 subjects from 550 families. Families were selected for the presence of two or more asthmatic children as part of a genetic study, Scandinavian Asthma Genetic Study (SAGA). The primary analysis studied the association between the lung function and delay of inhaled corticosteroids (ICS) after asthma diagnosis among asthmatic children and young adults with a history of regular ICS treatment (N=919). FEV(1) percent predicted (FEV(1)% pred) was 0.25% lower per year of delay from diagnosis until treatment (p=0.039). This association was significantly greater in allergy skin prick test negative children. There was no significant influence of gender, age at asthma onset, or smoking. In the secondary analysis of the whole population of 2390 asthmatics and non-asthmatics, FEV(1)% pred was inversely related to having asthmatic siblings (-7.9%; p<0.0001), asthma diagnosis (-2.7%; p=0.0007), smoking (-3.5%; p=0.0027), and positive allergy skin prick test (-0.47% per test; p=0.012), while positively related to being of female gender (1.8%; p=0.0029). Risk of AHR was higher by having asthmatic siblings (OR 2.7; p<0.0001), being of female gender (OR 2.0; p<0.0001), and having asthma (OR 2.0; p<0.0001). These data suggest that lung function is lower in asthmatics with delayed introduction of ICS therapy, smoking, and positive allergy skin prick test. Lung function is lower and AHR higher in female asthmatics and subjects with asthmatic siblings or established asthma.

  18. Association between lung capacity and abnormal glucose metabolism: findings from China and Australia.

    PubMed

    Yu, Dahai; Chen, Tao; Qin, Rui; Cai, Yamei; Jiang, Zhixin; Zhao, Zhanzheng; Simmons, David

    2016-07-01

    Restricted pulmonary function is found among people with diabetes. This study aimed to investigate the dose-response relationship between pulmonary function measurements [forced expiratory volume in one second (FEV1) and forced vital capacity (FVC)] and risk of metabolic syndrome (MS)/type 2 diabetes. A total of 1454 adults in rural Victoria, Australia, and 5824 adults in Nanjing, China, from randomly selected households provided clinical history, oral glucose tolerance test, lipids, anthropometric, blood pressure and spirometric measurements. MS was defined by International Diabetes Federation criteria. Adjusted odds ratios for MS and type 2 diabetes with lung capacity measurements were estimated using logistic regression. Dose-response relationships were explored using the restricted cubic spline models. There was a nonlinear relationship between FEV1 and the risk of type 2 diabetes and MS (both P < 0·0001) in both the Australian and Chinese populations. The FEV1 associated with the lowest risk of type 2 diabetes and MS was above 2·70 l (95%CI: 2·68 to 2·72 l and 2·65 to 2·76 l in Chinese and Australian populations, respectively). The discrimination of the model could be significantly improved using the FEV1 threshold in both the Australian and Chinese populations. In both the Australian and Chinese populations, the risk of type 2 diabetes and MS is lowest with a FEV1 of 2·65-2·76 l. This might be used in clinical practice in different countries as a prompt to screen for type 2 diabetes and MS in patients with obstructive lung disease and to ensure there was no abnormal glucose metabolism before the commencement of steroids if indicated. © 2015 John Wiley & Sons Ltd.

  19. Quantitative computed tomography of lung parenchyma in patients with emphysema: analysis of higher-density lung regions

    NASA Astrophysics Data System (ADS)

    Lederman, Dror; Leader, Joseph K.; Zheng, Bin; Sciurba, Frank C.; Tan, Jun; Gur, David

    2011-03-01

    Quantitative computed tomography (CT) has been widely used to detect and evaluate the presence (or absence) of emphysema applying the density masks at specific thresholds, e.g., -910 or -950 Hounsfield Unit (HU). However, it has also been observed that subjects with similar density-mask based emphysema scores could have varying lung function, possibly indicating differences of disease severity. To assess this possible discrepancy, we investigated whether density distribution of "viable" lung parenchyma regions with pixel values > -910 HU correlates with lung function. A dataset of 38 subjects, who underwent both pulmonary function testing and CT examinations in a COPD SCCOR study, was assembled. After the lung regions depicted on CT images were automatically segmented by a computerized scheme, we systematically divided the lung parenchyma into different density groups (bins) and computed a number of statistical features (i.e., mean, standard deviation (STD), skewness of the pixel value distributions) in these density bins. We then analyzed the correlations between each feature and lung function. The correlation between diffusion lung capacity (DLCO) and STD of pixel values in the bin of -910HU <= PV < -750HU was -0.43, as compared with a correlation of -0.49 obtained between the post-bronchodilator ratio (FEV1/FVC) measured by the forced expiratory volume in 1 second (FEV1) dividing the forced vital capacity (FVC) and the STD of pixel values in the bin of -1024HU <= PV < -910HU. The results showed an association between the distribution of pixel values in "viable" lung parenchyma and lung function, which indicates that similar to the conventional density mask method, the pixel value distribution features in "viable" lung parenchyma areas may also provide clinically useful information to improve assessments of lung disease severity as measured by lung functional tests.

  20. Measures of body habitus are associated with lung function in adults with cystic fibrosis: A population-based study☆

    PubMed Central

    Forrester, Doug L.; Knox, Alan J.; Smyth, Alan R.; Fogarty, Andrew W.

    2013-01-01

    Background Body habitus differences may explain some of the variation in lung function between individuals with cystic fibrosis (CF). We tested the hypothesis that measures of lean muscle mass and obesity are independently associated with lung function in CF. Methods Cross-sectional study design using UK CF registry data from 2096 clinically stable adults. Results Serum creatinine and BMI were positively and independently associated with FEV1 and FVC. One standard deviation increment in serum creatinine was associated with an FEV1 increase of 171 ml (95% confidence intervals CI: + 116 to + 227 ml) in males and 90 ml (95% CI: + 46 to + 133 ml) in females. Compared to the reference group of 20–24.9 kg/m2, those with a BMI < 20 kg/m2 had lower FEV1 with values of − 642 ml (95%CI: − 784 to − 500 ml) for males and − 468 ml (95%CI: − 564 to − 372 ml) for females. Conclusions Prospective studies and controlled trials are required to ascertain if these associations have therapeutic potential in modifying disease progression. PMID:22958983

  1. The effects of marijuana exposure on expiratory airflow. A study of adults who participated in the U.S. National Health and Nutrition Examination Study.

    PubMed

    Kempker, Jordan A; Honig, Eric G; Martin, Greg S

    2015-02-01

    Given the inconclusive science on the long-term effects of marijuana exposure on lung function, the increasing tetrahydrocannabinol composition of marijuana over time, and the increasing legal accessibility of the substance, continued investigation is needed. To determine the independent association between recent and chronic marijuana smoke exposure with spirometric parameters of lung function and symptoms of respiratory health in a large cohort of U.S. adults. This is a cross-sectional study of U.S. adults who participated in the National Health and Nutrition Examination Survey cycles from 2007-2008 and 2009-2010, using the data from standardized spirometry and survey questions performed during these years. In the combined 2007-2010 cohort, 59.1% replied that they had used marijuana at least once, and 12.2% had used in the past month. For each additional day of marijuana use in the prior month, there were no changes in percent predicted FEV1 (0.002 ± 0.04%; P = 0.9), but there was an associated increase in percent predicted FVC (0.13 ± 0.03%, P = 0.0001) and decrease in the FEV1/FVC ratio (-0.1 ± 0.04%; P < 0.0001). In multivariable regressions, 1-5 and 6-20 joint-years of marijuana use were not associated with an FEV1/FVC less than 70% (odds ratio [OR] = 1.1, 95% confidence interval [CI] = 0.7-1.6, P = 0.8, and OR = 1.2, 95% CI = 0.8-1.8, P = 0.4, respectively), whereas over 20 joint-years was associated with an FEV1/FVC less than 70% (OR = 2.1; 95% CI = 1.1-3.9; P = 0.02). For each additional marijuana joint-year smoked, there was no associated change in the mean percent predicted FEV1 (0.02 ± 0.02%; P = 1.00), an increase in percent predicted FVC (0.07 ± 0.02%; P = 0.004), and a decrease in FEV1/FVC (-0.03 ± 0.01%; P = 0.02). In a large cross-section of U.S. adults, cumulative lifetime marijuana use, up to 20 joint-years, is not associated with adverse changes in spirometric measures of lung health. Although greater than 20 joint-years of cumulative marijuana exposure was associated with a twofold increased odds of a FEV1/FVC less than 70%, this was the result of an increase in FVC, rather than a disproportional decrease in FEV1 as is typically associated with obstructive lung diseases.

  2. Effects of combinations of diesel exhaust and ozone exposure on lung function in human volunteers.

    EPA Science Inventory

    Ozone (03) exposure induces changes in human lung function, typically seen as a decrease in forced expiratory volume in one sec (FEV1) and forced vital capacity (FVC). Because people are usually exposed to other ambient air pollutants simultaneously with 03, there may be interact...

  3. Respiratory Effects of Fine and Ultrafine Particles from Indoor Sources—A Randomized Sham-Controlled Exposure Study of Healthy Volunteers

    PubMed Central

    Soppa, Vanessa J.; Schins, Roel P. F.; Hennig, Frauke; Hellack, Bryan; Quass, Ulrich; Kaminski, Heinz; Kuhlbusch, Thomas A. J.; Hoffmann, Barbara; Weinmayr, Gudrun

    2014-01-01

    Particulate air pollution is linked to impaired respiratory health. We analyzed particle emissions from common indoor sources (candles burning (CB), toasting bread (TB), frying sausages (FS)) and lung function in 55 healthy volunteers (mean age 33.0 years) in a randomized cross-over controlled exposure study. Lung-deposited particle surface area concentration (PSC), size-specific particle number concentration (PNC) up to 10 µm, and particle mass concentration (PMC) of PM1, PM2.5 and PM10 were determined during exposure (2 h). FEV1, FVC and MEF25%–75% was measured before, 4 h and 24 h after exposure. Wilcoxon-rank sum tests (comparing exposure scenarios) and mixed linear regression using particle concentrations and adjusting for personal characteristics, travel time and transportation means before exposure sessions were performed. While no effect was seen comparing the exposure scenarios and in the unadjusted model, inverse associations were found for PMC from CB and FS in relation to FEV1 and MEF25%–75%. with a change in 10 µg/m3 in PM2.5 from CB being associated with a change in FEV1 of −19 mL (95%-confidence interval:−43; 5) after 4 h. PMC from TB and PNC of UFP were not associated with lung function changes, but PSC from CB was. Elevated indoor fine particles from certain sources may be associated with small decreases in lung function in healthy adults. PMID:25000149

  4. Comparative study of lung functions in women working in different fibre industries.

    PubMed

    Khanam, F; Islam, N; Hai, M A

    2008-07-01

    A cross sectional work has been done on Bangladeshi females, working in different fibre industries, to study the effect of exposure to fibre dust on pulmonary functions. The ventilatory capacities were measured by VMI ventilometer in 653 apparently healthy women (160, 162 and 167 were jute, textile and garment industry workers, respectively). For the controls 164 females were recruited who never worked in any fibre industry. The observed FVC, FEV1 and PEFR were lower in all groups of fibre industry workers than those of the control. Among the industry workers, the jute mill workers had the lowest ventilatory capacities and garment industry workers had the highest values. The jute and textile mill workers had also significantly lower FEV1 and PEFR than those of garment industry workers. The FEV1 and PEFR were significantly lower in jute mill workers than those of textile ill workers. The low ventilatory capacities were almost proportionate with the length of service of the workers. Thus, the present study indicates that the fibre dust, on regular exposure for longer duration, may limit the lung functions.

  5. The association of lung function and St. George's respiratory questionnaire with exacerbations in COPD: a systematic literature review and regression analysis.

    PubMed

    Martin, Amber L; Marvel, Jessica; Fahrbach, Kyle; Cadarette, Sarah M; Wilcox, Teresa K; Donohue, James F

    2016-04-16

    This study investigated the relationship between changes in lung function (as measured by forced expiratory volume in one second [FEV1]) and the St. George's Respiratory Questionnaire (SGRQ) and economically significant outcomes of exacerbations and health resource utilization, with an aim to provide insight into whether the effects of COPD treatment on lung function and health status relate to a reduced risk for exacerbations. A systematic literature review was conducted in MEDLINE, Embase, and the Cochrane Central Register of Controlled Trials to identify randomized controlled trials of adult COPD patients published in English since 2002 in order to relate mean change in FEV1 and SGRQ total score to exacerbations and hospitalizations. These predictor/outcome pairs were analyzed using sample-size weighted regression analyses, which estimated a regression slope relating the two treatment effects, as well as a confidence interval and a test of statistical significance. Sixty-seven trials were included in the analysis. Significant relationships were seen between: FEV1 and any exacerbation (time to first exacerbation or patients with at least one exacerbation, p = 0.001); between FEV1 and moderate-to-severe exacerbations (time to first exacerbation, patients with at least one exacerbation, or annualized rate, p = 0.045); between SGRQ score and any exacerbation (time to first exacerbation or patients with at least one exacerbation, p = 0.0002) and between SGRQ score and moderate-to-severe exacerbations (time to first exacerbation or patients with at least one exacerbation, p = 0.0279; annualized rate, p = 0.0024). Relationships between FEV1 or SGRQ score and annualized exacerbation rate for any exacerbation or hospitalized exacerbations were not significant. The regression analysis demonstrated a significant association between improvements in FEV1 and SGRQ score and lower risk for COPD exacerbations. Even in cases of non-significant relationships, results were in the expected direction with few exceptions. The results of this analysis offer health care providers and payers a broader picture of the relationship between exacerbations and mean change in FEV1 as well as SGRQ score, and will help inform clinical and formulary-making decisions while stimulating new research questions for future prospective studies.

  6. Association of plasma sRAGE, but not esRAGE with lung function impairment in COPD.

    PubMed

    Gopal, Poornima; Reynaert, Niki L; Scheijen, Jean L J M; Schalkwijk, Casper G; Franssen, Frits M E; Wouters, Emiel F M; Rutten, Erica P A

    2014-02-25

    Plasma soluble Receptor for Advanced Glycation End Product (sRAGE) is considered as a biomarker in COPD. The contribution of endogenous sRAGE (esRAGE) to the pool of plasma sRAGE and the implication of both markers in COPD pathogenesis is however not clear yet. The aim of the current study was therefore to measure plasma levels of esRAGE comparative to total sRAGE in patients with COPD and a control group. Further, we established the relations of esRAGE and total sRAGE with disease specific characteristics such as lung function and DLCO, and with different circulating AGEs. Plasma levels of esRAGE and sRAGE were measured in an 88 patients with COPD and in 55 healthy controls. FEV1 (%predicted) and FEV1/VC (%) were measured in both groups; DLCO (%predicted) was measured in patients only. In this study population we previously reported that the AGE Nϵ-(carboxymethyl) lysine (CML) was decreased, Nϵ-(carboxyethyl) lysine (CEL) increased and pentosidine was not different in plasma of COPD patients compared to controls. Plasma esRAGE (COPD: 533.9 ± 412.4, CONTROLS: 848.7 ± 690.3 pg/ml; p = 0.000) was decreased in COPD compared to controls. No significant correlations were observed between plasma esRAGE levels and lung function parameters or plasma AGEs. A positive correlation was present between esRAGE and total sRAGE levels in the circulation. Confirming previous findings, total sRAGE (COPD: 512.6 ± 403.8, CONTROLS: 1834 ± 804.2 pg/ml; p < 0.001) was lower in patients compared to controls and was positively correlated FEV1 (r = 0.235, p = 0.032), FEV1/VC (r = 0.218, p = 0.047), and DLCO (r = 0.308, p = 0.006). sRAGE furthermore did show a significant positive association with CML (r = 0.321, p = 0.003). Although plasma esRAGE is decreased in COPD patients compared to controls, only total sRAGE showed a significant and independent association with FEV1, FEV1/VC and DLCO, indicating that total sRAGE but not esRAGE may serve as marker of COPD disease state and severity.

  7. Relationship between blood levels of heavy metals and lung function based on the Korean National Health and Nutrition Examination Survey IV–V

    PubMed Central

    Leem, Ah Young; Kim, Se Kyu; Chang, Joon; Kang, Young Ae; Kim, Young Sam; Park, Moo Suk; Kim, Song Yee; Kim, Eun Young; Chung, Kyung Soo; Jung, Ji Ye

    2015-01-01

    Background Heavy metal exposure may contribute to inflammation in the lungs via increased oxidative stress, resulting in tissue destruction and obstructive lung function (OLF). In this study, we evaluated the relationship between lead and cadmium levels in blood, and lung function in the Korean population. Methods Pooled cross-sectional data from 5,972 subjects who participated in the Korean National Health and Nutrition Examination Survey 2008–2012 were used for this study. OLF was defined as forced expiratory volume in 1 second/forced vital capacity (FEV1/FVC) <0.7. Graphite-furnace atomic absorption spectrometry was used to measure levels of lead and cadmium in blood. Results Adjusted means for age, sex, body mass index, and smoking status in blood lead and cadmium levels were increased with age and were higher in men and current smokers. The FEV1/FVC ratio was lower in the highest quartile group of lead (78.4% vs 79.0%; P=0.025) and cadmium (78.3% vs 79.2%; P<0.001) concentrations, compared with those in the lowest quartile groups. Multiple linear regression demonstrated an inverse relationship between the FEV1/FVC ratio and concentrations of lead (estimated −0.002; P=0.007) and cadmium (estimated −0.005; P=0.001). Of the 5,972 subjects, 674 (11.3%) were classified into the OLF group. Among current smokers, the risk of OLF was higher in subjects in the highest quartile group of cadmium concentration than in those in the lowest quartile group (odds ratio 1.94; 95% confidence interval 1.06–3.57). Conclusion We demonstrated a significant association between the FEV1/FVC ratio and blood concentrations of lead and cadmium in the Korean population. The risk for OLF was elevated with increasing concentrations of cadmium among current smokers. PMID:26345298

  8. Respiratory muscle adaptations: a comparison between bodybuilders and endurance athletes.

    PubMed

    Hackett, D A; Johnson, N; Chow, C

    2013-04-01

    The purpose of this study was to compare the respiratory muscle and lung function measures of bodybuilders (BB) and endurance athletes (EA). Forty-two male subjects (22 BB and 20 EA) aged 20-35 years underwent respiratory muscle strength measurements (MIP and MEP), lung function testing (FEV1, FVC, FEV1/FVC%, IC, ERV, FRC, RV, and TLC), hydrostatic weighing and VO2max testing. One-repetition maximum (1RM) for bench press, squat and deadlift was performed by BB. BB had significantly greater MIP and MEP compared to EA by 43% and 53% respectively (P<0.01). Moderate correlation was found for MEP and 1RM bench press (P<0.01), and weak correlations found for the squat and deadlift (P<0.01). Fat-free mass was significantly greater for BB compared with EA (P<0.01), while VO2max was significantly greater for EA compared with BB (P<0.01). No differences in lung function indices were observed between groups. When compared to EA, BB exhibited significantly greater respiratory muscle strength. The maximal load lifted for bench press predicted expiratory muscle strength gain. Lung function measures did not differ between the groups.

  9. The importance of phrenic nerve preservation and its effect on long-term postoperative lung function after pneumonectomy.

    PubMed

    Kocher, Gregor J; Poulson, Jannie Lysgaard; Blichfeldt-Eckhardt, Morten Rune; Elle, Bo; Schmid, Ralph A; Licht, Peter B

    2016-04-01

    The importance of phrenic nerve preservation during pneumonectomy remains controversial. We previously demonstrated that preservation of the phrenic nerve in the immediate postoperative period preserved lung function by 3-5% but little is known about its long-term effects. We, therefore, decided to investigate the effect of temporary ipsilateral cervical phrenic nerve block on dynamic lung volumes in mid- to long-term pneumonectomy patients. We investigated 14 patients after a median of 9 years post pneumonectomy (range: 1-15 years). Lung function testing (spirometry) and fluoroscopic and/or sonographic assessment of diaphragmatic motion on the pneumonectomy side were performed before and after ultrasonographic-guided ipsilateral cervical phrenic nerve block by infiltration with lidocaine. Ipsilateral phrenic nerve block was successfully achieved in 12 patients (86%). In the remaining 2 patients, diaphragmatic motion was already paradoxical before the nerve block. We found no significant difference on dynamic lung function values (FEV1 'before' 1.39 ± 0.44 vs FEV1 'after' 1.38 ± 0.40; P = 0.81). Induction of a temporary diaphragmatic palsy did not significantly influence dynamic lung volumes in mid- to long-term pneumonectomy patients, suggesting that preservation of the phrenic nerve is of greater importance in the immediate postoperative period after pneumonectomy. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Correlation analysis between pulmonary function test parameters and CT image parameters of emphysema

    NASA Astrophysics Data System (ADS)

    Liu, Cheng-Pei; Li, Chia-Chen; Yu, Chong-Jen; Chang, Yeun-Chung; Wang, Cheng-Yi; Yu, Wen-Kuang; Chen, Chung-Ming

    2016-03-01

    Conventionally, diagnosis and severity classification of Chronic Obstructive Pulmonary Disease (COPD) are usually based on the pulmonary function tests (PFTs). To reduce the need of PFT for the diagnosis of COPD, this paper proposes a correlation model between the lung CT images and the crucial index of the PFT, FEV1/FVC, a severity index of COPD distinguishing a normal subject from a COPD patient. A new lung CT image index, Mirage Index (MI), has been developed to describe the severity of COPD primarily with emphysema disease. Unlike conventional Pixel Index (PI) which takes into account all voxels with HU values less than -950, the proposed approach modeled these voxels by different sizes of bullae balls and defines MI as a weighted sum of the percentages of the bullae balls of different size classes and locations in a lung. For evaluation of the efficacy of the proposed model, 45 emphysema subjects of different severity were involved in this study. In comparison with the conventional index, PI, the correlation between MI and FEV1/FVC is -0.75+/-0.08, which substantially outperforms the correlation between PI and FEV1/FVC, i.e., -0.63+/-0.11. Moreover, we have shown that the emphysematous lesion areas constituted by small bullae balls are basically irrelevant to FEV1/FVC. The statistical analysis and special case study results show that MI can offer better assessment in different analyses.

  11. Adverse Respiratory Health and Hematological Alterations among Agricultural Workers Occupationally Exposed to Organophosphate Pesticides: A Cross-Sectional Study in North India

    PubMed Central

    Fareed, Mohd.; Pathak, Manoj Kumar; Bihari, Vipin; Kamal, Ritul; Srivastava, Anup Kumar; Kesavachandran, Chandrasekharan Nair

    2013-01-01

    Background Non-protective work practices followed by farm workers during spraying of pesticides lead to occupational exposure among them. Objective This study is designed to explore the respiratory health and hematological profile of agricultural workers occupationally exposed to OP pesticides. Materials and Methods A cross sectional study was undertaken among 166 pesticide sprayers working in mango orchards of Lucknow district in North India compared with 77 controls to assess the respiratory illness, lung functions, cholinesterase levels and hematological profile. A questionnaire based survey and clinical examination for respiratory health were conducted among study subjects. Lung function test was conducted among study subjects by using spirometer. Cholinesterase level as biomarker of OP pesticides and hematological profile of study subjects were investigated in the laboratory by following the standard protocols. Results Overall respiratory morbidity observed among exposed subjects was 36.75%. Symptoms for respiratory illness like dry cough, productive cough, wheezing, irritation of throat and blood stained sputum were found to be significantly more (p<0.05) among pesticide sprayers than controls. Lung function parameters viz. PEFR, FEV1, %PEFR predicted, %FEV1 predicted and FEV1/FVC were found to be significantly decreased (p<0.05) among pesticide sprayers as compared to controls. Exposure wise distribution of respiratory illness and lung functions among pesticide sprayers show that the exposure duration significantly elevates (p<0.05) the respiratory problems and significantly decreases (p<0.001) lung functions among pesticide sprayers. Activities of acetylcholinesterase and butyrylcholinesterase were found to be significantly depleted (p<0.001) among pesticide sprayers as compared to controls which show the exposure of OP pesticides among them. The hematological profile viz. RBC, WBC, monocytes, neutrophils, MCV, MCH, MCHC and platelet count were significantly altered (p<0.001) in pesticide sprayers than controls. Conclusion This study shows that the unsafe occupational exposure of OP pesticides causes respiratory illness, decreased lung functions and hematological alterations among pesticide sprayers. PMID:23936093

  12. Adverse respiratory health and hematological alterations among agricultural workers occupationally exposed to organophosphate pesticides: a cross-sectional study in North India.

    PubMed

    Fareed, Mohd; Pathak, Manoj Kumar; Bihari, Vipin; Kamal, Ritul; Srivastava, Anup Kumar; Kesavachandran, Chandrasekharan Nair

    2013-01-01

    Non-protective work practices followed by farm workers during spraying of pesticides lead to occupational exposure among them. This study is designed to explore the respiratory health and hematological profile of agricultural workers occupationally exposed to OP pesticides. A cross sectional study was undertaken among 166 pesticide sprayers working in mango orchards of Lucknow district in North India compared with 77 controls to assess the respiratory illness, lung functions, cholinesterase levels and hematological profile. A questionnaire based survey and clinical examination for respiratory health were conducted among study subjects. Lung function test was conducted among study subjects by using spirometer. Cholinesterase level as biomarker of OP pesticides and hematological profile of study subjects were investigated in the laboratory by following the standard protocols. Overall respiratory morbidity observed among exposed subjects was 36.75%. Symptoms for respiratory illness like dry cough, productive cough, wheezing, irritation of throat and blood stained sputum were found to be significantly more (p<0.05) among pesticide sprayers than controls. Lung function parameters viz. PEFR, FEV1, %PEFR predicted, %FEV1 predicted and FEV1/FVC were found to be significantly decreased (p<0.05) among pesticide sprayers as compared to controls. Exposure wise distribution of respiratory illness and lung functions among pesticide sprayers show that the exposure duration significantly elevates (p<0.05) the respiratory problems and significantly decreases (p<0.001) lung functions among pesticide sprayers. Activities of acetylcholinesterase and butyrylcholinesterase were found to be significantly depleted (p<0.001) among pesticide sprayers as compared to controls which show the exposure of OP pesticides among them. The hematological profile viz. RBC, WBC, monocytes, neutrophils, MCV, MCH, MCHC and platelet count were significantly altered (p<0.001) in pesticide sprayers than controls. This study shows that the unsafe occupational exposure of OP pesticides causes respiratory illness, decreased lung functions and hematological alterations among pesticide sprayers.

  13. Evaluation of respiratory variables in smelter and control workers before and during a shutdown period

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holness, D.L.; Batten, B.; Broder, I.

    1985-05-01

    Thirty-six smelter workers examined in this pilot study were found to have a higher prevalence of cough and dyspnea and lower baseline lung function than did 31 controls. They also experienced decreases in forced vital capacity (FVC) and forced expiratory volume in 1s (FEV1) over the workweek while the controls did not. Baseline airflow rates and change in FVC and FEV1 over the workweek varied with levels of sulfur dioxide and particulates. Twenty-three smelter workers and 21 controls were seen on a second occasion, six months into an extended shutdown. The smelter workers continued to have a higher prevalence ofmore » cough and dyspnea and lower baseline lung function than the controls. There was, however, a slight increase in lung function in both the exposed workers and the controls during the shutdown. The results suggest that smelter workers may develop both acute and chronic work-related pulmonary effects and that the chronic effects may be nonreversible.« less

  14. Dust is in the air. Part II: Effects of occupational exposure to welding fumes on lung function in a 9-year study.

    PubMed

    Haluza, Daniela; Moshammer, Hanns; Hochgatterer, Karl

    2014-02-01

    Adverse health effects of work-related contact with respirable hazardous substances are of great public interest. Because related prospective and long-term follow-up studies are rare, the extent of acute and chronic pulmonary health risks of occupational exposure to welding fumes is discussed controversially in the scientific literature. The objective of the present longitudinal study during a 9-year period was to investigate the annual changes of lung function in welders. Anthropometric measures and smoking behaviour, and spirometric tests (FVC, FEV1, and MEF50) obtained during routine occupational health checkups of female and male workers (n = 1,982) in Austria during the years 2002-2010 were analyzed. The study participants displayed average lung function values lower than the age- and sex-specific norm. Decrease in respiratory capacity was dependent on smoking habits and duration of occupational exposure. Specifically for welders (n = 1,326), decrease of pulmonary function was significantly associated with heavy smoking (FVC -70.7 ml, p = 0.07; FEV1 -167.4 ml, p < 0.001; MEF50 -356.2 ml/s, p < 0.001), but not with moderate smoking habits, and also with duration of occupational exposure to welding fumes per year (FVC -0.89 ml, p = 0.36; FEV1 -2.91 ml, p < 0.001; MEF50 -4.7 ml/s, p = 0.047). Individual smoking habits as well as duration of occupational exposure to welding fumes showed a negative impact on lung function parameters. To reduce the risk of work-associated respiratory morbidity, smoking cessation is highly recommended to personnel engaged in welding fumes- and dust-exposed occupations.

  15. Longitudinal Lung Function Growth of Mexican Children Compared with International Studies

    PubMed Central

    Martínez-Briseño, David; Fernández-Plata, Rosario; Gochicoa-Rangel, Laura; Torre-Bouscoulet, Luis; Rojas-Martínez, Rosalba; Mendoza, Laura; García-Sancho, Cecilia; Pérez-Padilla, Rogelio

    2013-01-01

    Introduction Our aim was to compare the longitudinal lung function growth of Mexican children and adolescents with the collated spirometric reference proposed for international use and with that of Mexican-Americans from the National Health State Examination Survey III (NHANES) III study. Materials and Methods A cohort of Mexican children in third year of primary school was followed with spirometry twice a year through secondary school. Multilevel mixed-effects lineal models separated by gender were fit for the spirometric variables of 2,641 respiratory-healthy Mexican children expressed as Z-scores of tested reference equations. Impact of adjustment by sitting height on differences with Mexican-American children was observed in a subsample of 1,987 children. Results At same gender, age, and height, Mexican children had increasingly higher forced expiratory volume in 1 s (FEV1) and Forced vital capacity (FVC) than the children from the collated reference study (mean Z-score, 0.68 for FEV1 and 0.51 for FVC) and than Mexican-American children (Z-score, 0.23 for FEV1 and 0.21 for FVC) respectively. Differences with Mexican-Americans were not reduced by adjusting by sitting height. Conclusions For reasons that remain unclear, the gender-, age-, and height-adjusted lung function of children from Mexico City is higher than that reported by several international studies. PMID:24143231

  16. African ancestry and lung function in Puerto Rican children.

    PubMed

    Brehm, John M; Acosta-Pérez, Edna; Klei, Lambertus; Roeder, Kathryn; Barmada, Michael M; Boutaoui, Nadia; Forno, Erick; Cloutier, Michelle M; Datta, Soma; Kelly, Roxanne; Paul, Kathryn; Sylvia, Jody; Calvert, Deanna; Thornton-Thompson, Sherell; Wakefield, Dorothy; Litonjua, Augusto A; Alvarez, María; Colón-Semidey, Angel; Canino, Glorisa; Celedón, Juan C

    2012-06-01

    Puerto Rican and African American subjects share a significant proportion of African ancestry. Recent findings suggest that African ancestry influences lung function in African American adults. We sought to examine whether a greater proportion of African ancestry is associated with lower FEV(1) and forced vital capacity (FVC) in Puerto Rican children independently of socioeconomic status, health care access, or key environmental/lifestyle factors. We performed a cross-sectional case-control study of 943 Puerto Rican children aged 6 to 14 years with (n= 520) and without (n= 423) asthma (defined as physician-diagnosed asthma and wheeze in the prior year) living in Hartford, Connecticut (n= 383), and San Juan, Puerto Rico (n= 560). We estimated the percentage of African racial ancestry in study participants using genome-wide genotypic data. We tested whether African ancestry is associated with FEV(1) and FVC using linear regression. Multivariate models were adjusted for indicators of socioeconomic status and health care and selected environmental/lifestyle exposures. After adjustment for household income and other covariates, each 20% increment in African ancestry was significantly associated with lower prebronchodilator FEV(1) (-105 mL; 95% CI, -159 to -51 mL; P< .001) and FVC (-133 mL; 95% CI, -197 to -69 mL; P< .001) and postbronchodilator FEV(1) (-152 mL; 95% CI, -210 to -94 mL; P< .001) and FVC (-145 mL; 95% CI, -211 to -79 mL; P< .001) in children with asthma. Similar but weaker associations were found for prebronchodilator and postbronchodilator FEV(1) (change for each 20% increment in African ancestry, -78 mL; 95% CI, -131 to -25 mL; P= .004) and for postbronchodilator FVC among children without asthma. Genetic factors, environmental/lifestyle factors, or both correlated with African ancestry might influence childhood lung function in Puerto Rican subjects. Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  17. African Ancestry and Lung Function in Puerto Rican Children

    PubMed Central

    Brehm, John M.; Acosta-Pérez, Edna; Klei, Lambertus; Roeder, Kathryn; Barmada, Michael; Boutaoui, Nadia; Forno, Erick; Cloutier, Michelle; Datta, Soma; Kelly, Roxanne; Paul, Kathryn; Sylvia, Jody; Calvert, Deanna; Thornton-Thompson, Sherell; Wakefield, Dorothy; Litonjua, Augusto A.; Alvarez, María; Colón-Semidey, Angel; Canino, Glorisa; Celedón, Juan C.

    2012-01-01

    Background Puerto Ricans and African Americans share a significant proportion of African ancestry. Recent findings suggest that African ancestry influences lung function in African American adults. Objective To examine whether a greater proportion of African ancestry is associated with lower FEV1 and FVC in Puerto Rican children, independently of socioeconomic status (SES), healthcare access or key environmental/lifestyle (EL) factors. Methods Cross-sectional case-control study of 943 Puerto Rican children ages 6 to 14 years with (n=520) and without (n=423) asthma (defined as physician-diagnosed asthma and wheeze in the prior year) living in Hartford (CT, n=383) and San Juan (PR, n=560). We estimated the percentage of African racial ancestry in study participants using genome-wide genotypic data. We tested whether African ancestry is associated with FEV1 and FVC using linear regression. Multivariate models were adjusted for indicators of SES and healthcare, and selected EL exposures. Results After adjustment for household income and other covariates, each 20% increment in African ancestry was significantly associated with lower pre-bronchodilator(BD) FEV1 (−105 ml, 95% confidence interval [CI] = −159 ml to −51 ml, P <0.001) and FVC (−133 ml, 95% CI −197 ml to −69 ml, P <0.001), and post-BD FEV1 (−152 ml, 95% CI=−210 ml to −94 ml, P <0.001) and FVC (−145 ml, 95% CI= −211 to −79 ml, P <0.001) in children with asthma. Similar but weaker associations were found for pre- and post-BD FEV1 (change for each 20% increment in African ancestry= −78 ml, 95% CI= −131 to −25 ml, P=0.004), and for post-BD FVC among children without asthma. Conclusions Genetic and/or EL factors correlated with African ancestry may influence childhood lung function in Puerto Ricans. PMID:22560959

  18. Occupational airborne exposure in relation to Chronic Obstructive Pulmonary Disease (COPD) and lung function in individuals without childhood wheezing illness: A 50-year cohort study.

    PubMed

    Tagiyeva, Nara; Sadhra, Steven; Mohammed, Nuredin; Fielding, Shona; Devereux, Graham; Teo, Ed; Ayres, Jon; Graham Douglas, J

    2017-02-01

    Evidence from longitudinal population-based studies relating occupational exposure to the full range of different forms of airborne pollutants and lung function and airway obstruction is limited. To relate self-reported COPD and lung function impairment to occupational exposure to different forms of airborne chemical pollutants in individuals who did not have childhood wheeze. A prospective cohort study was randomly selected in 1964 at age 10-15 years and followed up in 1989, 1995, 2001 and 2014 (aged 58-64) by spirometry and respiratory questionnaire. Occupational histories were recorded in 2014 and occupational exposures assigned using an airborne chemical job exposure matrix. The risk of COPD and lung function impairment was analyzed in subjects, who did not have childhood wheeze, using logistic and linear regression and linear mixed effects models. 237 subjects without childhood wheeze (mean age 60.6 years, 47% male) were analyzed. There was no association between any respiratory outcomes and exposure to gases, fibers, mists or mineral dusts and no consistent associations with exposure to fumes. Reduced FEV 1 was associated with longer duration (years) of exposure to any of the six main pollutant forms - vapors, gases, dusts, fumes, fibers and mists (VGDFFiM) with evidence of a dose-response relationship (p-trend=0.004). Exposure to biological dusts was associated with self-reported COPD and FEV 1

  19. Overall and peripheral lung function assessment by spirometry and forced oscillation technique in relation to asthma diagnosis and control.

    PubMed

    Heijkenskjöld Rentzhog, C; Janson, C; Berglund, L; Borres, M P; Nordvall, L; Alving, K; Malinovschi, A

    2017-12-01

    Classic spirometry is effort dependent and of limited value in assessing small airways. Peripheral airway involvement, and relation to poor control, in asthma, has been highlighted recently. Forced oscillation technique (FOT) offers an effort-independent assessment of overall and peripheral lung mechanics. We studied the association between lung function variables, obtained either by spirometry or multifrequency (5, 11 and 19 Hz) FOT, and asthma diagnosis and control. Spirometry measures, resistance at 5 (R5) and 19 Hz (R19), reactance at 5 Hz (X5), resonant frequency (f res ), resistance difference between 5-19 Hz (R5-R19) and Asthma Control Test scores were determined in 234 asthmatic and 60 healthy subjects (aged 13-39 years). We used standardized lung function variables in logistic regression analyses, unadjusted and adjusted for age, height, gender and weight. Lower FEV 1 /FVC (OR [95% CI] 0.47 [0.32, 0.69]) and FEF 50 (0.62 [0.46, 0.85]) per standard deviation increase, and higher R5 (3.31 [1.95, 5.62]) and R19 (2.54 [1.65, 3.91]) were associated with asthma diagnosis. Independent predictive effects of FEV 1 /FVC and R5 or R19, respectively, were found for asthma diagnosis. Lower FEV 1 /FVC and altered peripheral FOT measures (X5, f res and R5-R19) were associated with uncontrolled asthma (P-values < .05). Resistance FOT measures were equally informative as spirometry, related to asthma diagnosis, and, furthermore, offered additive information to FEV 1 /FVC, supporting a complementary role for FOT. Asthma control was related to FOT measures of peripheral airways, suggesting a potential use in identifying such involvement. Further studies are needed to determine a clinical value and relevant reference values in children, for the multifrequency FOT measurements. © 2017 John Wiley & Sons Ltd.

  20. Acute Exacerbations and Lung Function Loss in Smokers with and without Chronic Obstructive Pulmonary Disease.

    PubMed

    Dransfield, Mark T; Kunisaki, Ken M; Strand, Matthew J; Anzueto, Antonio; Bhatt, Surya P; Bowler, Russell P; Criner, Gerard J; Curtis, Jeffrey L; Hanania, Nicola A; Nath, Hrudaya; Putcha, Nirupama; Roark, Sarah E; Wan, Emily S; Washko, George R; Wells, J Michael; Wendt, Christine H; Make, Barry J

    2017-02-01

    Acute exacerbations of chronic obstructive pulmonary disease (COPD) increase the risk of death and drive healthcare costs, but whether they accelerate loss of lung function remains controversial. Whether exacerbations in subjects with mild COPD or similar acute respiratory events in smokers without airflow obstruction affect lung function decline is unknown. To determine the association between acute exacerbations of COPD (and acute respiratory events in smokers without COPD) and the change in lung function over 5 years of follow-up. We examined data on the first 2,000 subjects who returned for a second COPDGene visit 5 years after enrollment. Baseline data included demographics, smoking history, and computed tomography emphysema. We defined exacerbations (and acute respiratory events in those without established COPD) as acute respiratory symptoms requiring either antibiotics or systemic steroids, and severe events by the need for hospitalization. Throughout the 5-year follow-up period, we collected self-reported acute respiratory event data at 6-month intervals. We used linear mixed models to fit FEV 1 decline based on reported exacerbations or acute respiratory events. In subjects with COPD, exacerbations were associated with excess FEV 1 decline, with the greatest effect in Global Initiative for Chronic Obstructive Lung Disease stage 1, where each exacerbation was associated with an additional 23 ml/yr decline (95% confidence interval, 2-44; P = 0.03), and each severe exacerbation with an additional 87 ml/yr decline (95% confidence interval, 23-151; P = 0.008); statistically significant but smaller effects were observed in Global Initiative for Chronic Obstructive Lung Disease stage 2 and 3 subjects. In subjects without airflow obstruction, acute respiratory events were not associated with additional FEV 1 decline. Exacerbations are associated with accelerated lung function loss in subjects with established COPD, particularly those with mild disease. Trials are needed to test existing and novel therapies in subjects with early/mild COPD to potentially reduce the risk of progressing to more advanced lung disease. Clinical trial registered with www.clinicaltrials.gov (NCT 00608764).

  1. Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?

    PubMed

    Kjeldgaard, Peter; Lykkegaard, Jesper; Spillemose, Heidi; Ulrik, Charlotte Suppli

    2017-01-01

    Early detection of COPD may reduce the future burden of the disease. We aimed to investigate whether prescreening with a COPD-6 screening device (measuring FEV 1 and FEV 6 ) facilitates early detection of COPD in primary care. In primary care, individuals at high risk of COPD (ie, age ≥35 years, relevant exposure, and at least one respiratory symptom) and no previous diagnosis of obstructive lung disease were examined with a COPD-6 screening device. In prioritized order, the criteria for proceeding to confirmatory spirometry were FEV 1 /FEV 6 <0.7, FEV 1 <80%pred, or clinical suspicion of COPD regardless of test result (medical doctor's [MD] decision). Based on spirometry, including bronchodilator (BD) reversibility test, individuals were classified as COPD (post-BD FEV 1 /FVC <0.70), asthma (ΔFEV 1 ≥0.50 L), or no obstructive lung disease. A total of 2,990 subjects (54% men, mean age 59 years, and mean 28 pack-years) were enrolled, of whom 949 (32%) proceeded from COPD-6 screening to confirmative spirometry based on the following criteria: 510 (54%) FEV 1 /FEV 6 <0.70, 382 (40%) FEV 1 <80%pred, and 57 (6%) MD decision. Following confirmative spirometry, the 949 individuals were diagnosed as having COPD (51%), asthma (3%), and no obstructive lung disease (45%). COPD was diagnosed in 487 (16%) of the enrolled subjects in whom confirmative spirometry was performed in 69% based on FEV 1 /FEV 6 <0.7 and in 29% based on FEV 1 ≤80%pred. Prescreening with the COPD-6 device showed acceptable specificity for the selection of subjects for diagnostic spirometry and is likely to be a useful alternative to current practice in primary care.

  2. Chronic effects of air pollution on lung function after lung transplantation in the Systems prediction of Chronic Lung Allograft Dysfunction (SysCLAD) study.

    PubMed

    Benmerad, Meriem; Slama, Rémy; Botturi, Karine; Claustre, Johanna; Roux, Antoine; Sage, Edouard; Reynaud-Gaubert, Martine; Gomez, Carine; Kessler, Romain; Brugière, Olivier; Mornex, Jean-François; Mussot, Sacha; Dahan, Marcel; Boussaud, Véronique; Danner-Boucher, Isabelle; Dromer, Claire; Knoop, Christiane; Auffray, Annick; Lepeule, Johanna; Malherbe, Laure; Meleux, Frederik; Nicod, Laurent; Magnan, Antoine; Pison, Christophe; Siroux, Valérie

    2017-01-01

    An irreversible loss in lung function limits the long-term success in lung transplantation. We evaluated the role of chronic exposure to ambient air pollution on lung function levels in lung transplant recipients (LTRs).The lung function of 520 LTRs from the Cohort in Lung Transplantation (COLT) study was measured every 6 months. The levels of air pollutants (nitrogen dioxide (NO 2 ), particulate matter with an aerodynamic cut-off diameter of x µm (PM x ) and ozone (O 3 )) at the patients' home address were averaged in the 12 months before each spirometry test. The effects of air pollutants on forced expiratory volume in 1 s (FEV 1 ) and forced vital capacity (FVC) in % predicted were estimated using mixed linear regressions. We assessed the effect modification of macrolide antibiotics in this relationship.Increased 12-month levels of pollutants were associated with lower levels of FVC % pred (-2.56%, 95% CI -3.86--1.25 for 5 µg·m -3 of PM 10 ; -0.75%, 95% CI -1.38--0.12 for 2 µg·m -3 of PM 2.5 and -2.58%, 95% CI -4.63--0.53 for 10 µg·m -3 of NO 2 ). In patients not taking macrolides, the deleterious association between PM and FVC tended to be stronger and PM 10 was associated with lower FEV 1 Our study suggests a deleterious effect of chronic exposure to air pollutants on lung function levels in LTRs, which might be modified with macrolides. Copyright ©ERS 2017.

  3. Chest wall mobility is related to respiratory muscle strength and lung volumes in healthy subjects.

    PubMed

    Lanza, Fernanda de Cordoba; de Camargo, Anderson Alves; Archija, Lilian Rocha Ferraz; Selman, Jessyca Pachi Rodrigues; Malaguti, Carla; Dal Corso, Simone

    2013-12-01

    Chest wall mobility is often measured in clinical practice, but the correlations between chest wall mobility and respiratory muscle strength and lung volumes are unknown. We investigate the associations between chest wall mobility, axillary and thoracic cirtometry values, respiratory muscle strength (maximum inspiratory pressure and maximum expiratory pressure), and lung volumes (expiratory reserve volume, FEV(1), inspiratory capacity, FEV(1)/FVC), and the determinants of chest mobility in healthy subjects. In 64 healthy subjects we measured inspiratory capacity, FVC, FEV(1), expiratory reserve volume, maximum inspiratory pressure, and maximum expiratory pressure, and chest wall mobility via axillary and thoracic cirtometry. We used linear regression to evaluate the influence of the measured variables on chest wall mobility. The subjects' mean ± SD values were: age 24 ± 3 years, axillary cirtometry 6.3 ± 2.0 cm, thoracic cirtometry 7.5 ± 2.3 cm; maximum inspiratory pressure 90.4 ± 10.6% of predicted, maximum expiratory pressure 92.8 ± 13.5% of predicted, inspiratory capacity 99.7 ± 8.6% of predicted, FVC 101.9 ± 10.6% of predicted, FEV(1) 98.2 ± 10.3% of predicted, expiratory reserve volume 90.9 ± 19.9% of predicted. There were significant correlations between axillary cirtometry and FVC (r = 0.32), FEV(1) (r = 0.30), maximum inspiratory pressure (r = 0.48), maximum expiratory pressure (r = 0.25), and inspiratory capacity (r = 0.24), and between thoracic cirtometry and FVC (r = 0.50), FEV(1) (r = 0.48), maximum inspiratory pressure (r = 0.46), maximum expiratory pressure (r = 0.37), inspiratory capacity (r = 0.39), and expiratory reserve volume (r = 0.47). In multiple regression analysis the variable that best explained the axillary cirtometry variation was maximum inspiratory pressure (R(2) 0.23), and for thoracic cirtometry it was FVC and maximum inspiratory pressure (R(2) 0.32). Chest mobility in healthy subjects is related to respiratory muscle strength and lung function; the higher the axillary cirtometry and thoracic cirtometry values, the greater the maximum inspiratory pressure, maximum expiratory pressure, and lung volumes in healthy subjects.

  4. Menopause Is Associated with Accelerated Lung Function Decline.

    PubMed

    Triebner, Kai; Matulonga, Bobette; Johannessen, Ane; Suske, Sandra; Benediktsdóttir, Bryndís; Demoly, Pascal; Dharmage, Shyamali C; Franklin, Karl A; Garcia-Aymerich, Judith; Gullón Blanco, José Antonio; Heinrich, Joachim; Holm, Mathias; Jarvis, Debbie; Jõgi, Rain; Lindberg, Eva; Moratalla Rovira, Jesús Martínez; Muniozguren Agirre, Nerea; Pin, Isabelle; Probst-Hensch, Nicole; Puggini, Luca; Raherison, Chantal; Sánchez-Ramos, José Luis; Schlünssen, Vivi; Sunyer, Jordi; Svanes, Cecilie; Hustad, Steinar; Leynaert, Bénédicte; Gómez Real, Francisco

    2017-04-15

    Menopause is associated with changes in sex hormones, which affect immunity, inflammation, and osteoporosis and may impair lung function. Lung function decline has not previously been investigated in relation to menopause. To study whether lung function decline, assessed by FVC and FEV 1 , is accelerated in women who undergo menopause. The population-based longitudinal European Community Respiratory Health Survey provided serum samples, spirometry, and questionnaire data about respiratory and reproductive health from three study waves (n = 1,438). We measured follicle-stimulating hormone and luteinizing hormone and added information on menstrual patterns to determine menopausal status using latent class analysis. Associations with lung function decline were investigated using linear mixed effects models, adjusting for age, height, weight, pack-years, current smoking, age at completed full-time education, spirometer, and including study center as random effect. Menopausal status was associated with accelerated lung function decline. The adjusted mean FVC decline was increased by -10.2 ml/yr (95% confidence interval [CI], -13.1 to -7.2) in transitional women and -12.5 ml/yr (95% CI, -16.2 to -8.9) in post-menopausal women, compared with women menstruating regularly. The adjusted mean FEV 1 decline increased by -3.8 ml/yr (95% CI, -6.3 to -2.9) in transitional women and -5.2 ml/yr (95% CI, -8.3 to -2.0) in post-menopausal women. Lung function declined more rapidly among transitional and post-menopausal women, in particular for FVC, beyond the expected age change. Clinicians should be aware that respiratory health often deteriorates during reproductive aging.

  5. MMP12, lung function, and COPD in high-risk populations.

    PubMed

    Hunninghake, Gary M; Cho, Michael H; Tesfaigzi, Yohannes; Soto-Quiros, Manuel E; Avila, Lydiana; Lasky-Su, Jessica; Stidley, Chris; Melén, Erik; Söderhäll, Cilla; Hallberg, Jenny; Kull, Inger; Kere, Juha; Svartengren, Magnus; Pershagen, Göran; Wickman, Magnus; Lange, Christoph; Demeo, Dawn L; Hersh, Craig P; Klanderman, Barbara J; Raby, Benjamin A; Sparrow, David; Shapiro, Steven D; Silverman, Edwin K; Litonjua, Augusto A; Weiss, Scott T; Celedón, Juan C

    2009-12-31

    Genetic variants influencing lung function in children and adults may ultimately lead to the development of chronic obstructive pulmonary disease (COPD), particularly in high-risk groups. We tested for an association between single-nucleotide polymorphisms (SNPs) in the gene encoding matrix metalloproteinase 12 (MMP12) and a measure of lung function (prebronchodilator forced expiratory volume in 1 second [FEV(1)]) in more than 8300 subjects in seven cohorts that included children and adults. Within the Normative Aging Study (NAS), a cohort of initially healthy adult men, we tested for an association between SNPs that were associated with FEV(1) and the time to the onset of COPD. We then examined the relationship between MMP12 SNPs and COPD in two cohorts of adults with COPD or at risk for COPD. The minor allele (G) of a functional variant in the promoter region of MMP12 (rs2276109 [-82A-->G]) was positively associated with FEV(1) in a combined analysis of children with asthma and adult former and current smokers in all cohorts (P=2x10(-6)). This allele was also associated with a reduced risk of the onset of COPD in the NAS cohort (hazard ratio, 0.65; 95% confidence interval [CI], 0.46 to 0.92; P=0.02) and with a reduced risk of COPD in a cohort of smokers (odds ratio, 0.63; 95% CI, 0.45 to 0.88; P=0.005) and among participants in a family-based study of early-onset COPD (P=0.006). The minor allele of a SNP in MMP12 (rs2276109) is associated with a positive effect on lung function in children with asthma and in adults who smoke. This allele is also associated with a reduced risk of COPD in adult smokers. 2009 Massachusetts Medical Society

  6. [Value of forced expiratory volume in 6 seconds (FEV(6)) in the evaluation of pulmonary function in Chinese elderly males].

    PubMed

    Pan, M M; Zhang, H S; Sun, T Y

    2017-05-30

    Objective: To evaluate the value of forced expiratory volume in 6 seconds (FEV(6)) in the evaluation of pulmonary function in Chinese elderly males. Methods: Pulmonary function tests of elderly who had received regular physical examination in Beijing Hospital from July 2003 to April 2015 were analyzed on subjects with the following characteristics: aged 60 years or older, completion of bronchial dilation test and able to exhale for at least six seconds. The included subjects were divided into 2 groups: 60-<80 years group and ≥80 years group. The association of FEV(6) with forced vital capacity (FVC), FEV(1)/FEV(6) with FEV(1)/FVC, the diagnostic efficiency and influencing factor of FEV(6) and FEV(1)/FEV(6) were analyzed; the value of FEV(6) in the evaluation of pulmonary function in the study population was evaluated. Results: A total of 475 elderly men aged 60 years or older were enrolled, with a mean age of (77.13±9.53) years. Totally there were 269 subjects in 60-<80 years group, which accounted for 56.6%; 206 subjects were in ≥80 years group, which accounted for 43.4%. There were 292 subjects with irreversible airflow obstruction, accounting for 61.5%. In all the included subjects, FEV(6) was significantly correlated with FVC and post-bronchodilator FEV(1)/FEV(6) was significantly correlated with post-bronchodilator FEV(1)/FVC( r =0.971, 0.978; both P <0.001), which were similar in 60-<80 years group and ≥80 years group ( r =0.967, 0.974 and r =0.955, 0.967; all P <0.001). FEV(1)/FEV(6) showed excellent accuracy in diagnosing airflow obstruction[area under curve (AUC)=0.990(95% CI: 0.983-0.996); P <0.001]. Using FEV(1)/FVC<0.70 as a reference, FEV(1)/FEV(6)<0.73 had the best sensitivity (0.952) and specificity (0.945), and there was excellent agreement between the two diagnostic cutoffs (κ=0.891; P <0.001). When difference between before and after bronchial dilation test was analyzed, no correlation was observed between FEV(6) improvement and the improvement of forced expiratory time ( r =0.089; P =0.053), but FVC improvement was significantly correlated with the improvement of forced expiratory time ( r =0.460; P <0.001). Similar results were also found in subjects with irreversible airflow obstruction. Subjects with FEV(1)/FEV(6)≥0.70 and FEV(1)/FVC<0.70 were categorized as pulmonary function middle group, a total of 73 cases, which included 20 cases ≥80 years old. The proportion of middle group among ≥80 years group was significantly less than that of the 60-<80 years group (χ(2)=8.958; P =0.003). In pulmonary function middle group, FEV(1)/FEV(6) or FEV(1)/FVC had no correlation with inspiratory capacity or residual volume/total lung capacity (all P >0.05). Conclusions: FEV(6) and FEV(1)/FEV(6) are strongly correlated with FVC and FEV(1)/FVC, and there is excellent agreement between FEV(1)/FEV(6) and FEV(1)/FVC. FEV(6) is simple, easy to operate and with less influencing factors, which can be used as a valid alternative for FVC in diagnosing airflow obstruction in elderly males.

  7. Spirometric reference values in urban children in Madagascar: poverty is a risk factor for low lung function.

    PubMed

    Wolff, Peter Th; Arison, Lala; Rahajamiakatra, Abel; Raserijaona, Francis; Niggemann, Bodo

    2014-01-01

    Studies about children with respiratory diseases in Africa are impeded by the dearth of reliable data for the vast majority of countries on the continent. This study was conducted to establish representative reference values, therefore allowing a more accurate evaluation of lung function in Malagasy children. One thousand two hundred thirty-six students from three public and five private schools aged 8-12 years were recruited. A total of 1,093 children were healthy, had a valid lung function measurement and were thus deemed evaluable for this study. Lung function data were collected on consecutive days in Antananarivo, Madagascar's capital, using spirometry and a modified International Study of Asthma and Allergies in Childhood (ISAAC) questionnaire. The lung volumes found were substantially lower compared to Caucasian and African equations. The mean Z-score (Stanojevic) for the forced vital capacity (FVC) found was -1.45 and -0.93 for the forced expiratory volume in 1 sec (FEV1) with significant differences between private and public schools (FVC: P = 0.0023, FEV1: P = 0.0004). The equations established for school children in Madagascar's capital Antananarivo showed lung function values were lower than reference values for the same age group seen not only in European, but also in African American and African children. The unique ethnicity of the Malagasy people, which combines Southeast-Asian with substantial African influences, the heavy burden of pollution and poverty may explain these differences. © 2013 Wiley Periodicals, Inc.

  8. Correlations between FEV1 and patient-reported outcomes: A pooled analysis of 23 clinical trials in patients with chronic obstructive pulmonary disease.

    PubMed

    Donohue, James F; Jones, Paul W; Bartels, Christian; Marvel, Jessica; D'Andrea, Peter; Banerji, Donald; Morris, David G; Patalano, Francesco; Fogel, Robert

    2018-04-01

    In clinical trials of inhaled bronchodilators, chronic obstructive pulmonary disease (COPD) guidelines recommend that patient-reported outcomes (PROs) are assessed alongside lung function. How these endpoints are related is unclear. Pooled longitudinal data from 23 randomised controlled COPD studies were analyzed (N = 23,213). Treatments included long-acting β 2 agonists, long-acting muscarinic antagonists (LABAs or LAMAs) and the LABA/LAMA combination QVA149. Outcome measures were Transition Dyspnoea Index (TDI) and St. George's Respiratory Questionnaire (SGRQ) scores, COPD exacerbation frequency and rescue medication use. Relationships between changes in trough forced expiratory volume in one second (ΔFEV 1 ) and outcomes following treatment were assessed using correlations of data summaries and model-based analysis: generalized linear mixed-effect regression modelling to determine if ΔFEV 1 could predict patient outcomes with different treatments. Mean age was 64 years, 73% were male, and most had moderate (45%) or severe (52%) disease. Statistically significant correlations were observed between ΔFEV 1 and each outcome measure (exacerbations Rs = 0.05; rescue medication, SGRQ, TDI, r = 0.11-0.16; all p < .001). Patients with greater improvements in trough FEV 1 had on average better SGRQ and TDI scores, fewer exacerbations, and used less rescue medication. For SGRQ and TDI scores, minimal clinically important differences were observed over the range of pooled ΔFEV 1 values. Model-based predictions confirmed the treatment effect was partly explained by changes in FEV 1 from baseline with improvements in PROs observed across all treatments when trough FEV 1 improved. Across all endpoints active treatments were better than placebo (p < .0001), and LABA/LAMA treatment resulted in numerically better treatment outcomes than either monocomponent. These data suggest that FEV 1 improvements post-bronchodilation correlate with PRO improvements. Further improvements in patient outcomes may be expected by maximizing lung function improvements. Registration details for the 23 randomised controlled studies used in this pooled analysis are supplied in Additional File 4. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Sustained Effects of Sirolimus on Lung Function and Cystic Lung Lesions in Lymphangioleiomyomatosis

    PubMed Central

    Yao, Jianhua; Jones, Amanda M.; Julien-Williams, Patricia; Stylianou, Mario; Moss, Joel

    2014-01-01

    Rationale: Sirolimus therapy stabilizes lung function and reduces the size of chylous effusions and lymphangioleiomyomas in patients with lymphangioleiomyomatosis. Objectives: To determine whether sirolimus has beneficial effects on lung function, cystic areas, and adjacent lung parenchyma; whether these effects are sustained; and whether sirolimus is well tolerated by patients. Methods: Lung function decline over time, lung volume occupied by cysts (cyst score), and lung tissue texture in the vicinity of the cysts were quantified with a computer-aided diagnosis system in 38 patients. Then we compared cyst scores from the last study on sirolimus with studies done on sirolimus therapy. In 12 patients, we evaluated rates of change in lung function and cyst scores off and on sirolimus. Measurements and Main Results: Sirolimus reduced yearly declines in FEV1 (−2.3 ± 0.1 vs. 1.0 ± 0.3% predicted; P < 0.001) and diffusing capacity of carbon monoxide (−2.6 ± 0.1 vs. 0.9 ± 0.2% predicted; P < 0.001). Cyst scores 1.2 ± 0.8 years (30.5 ± 11.9%) and 2.5 ± 2 years (29.7 ± 12.1%) after initiating sirolimus were not significantly different from pretreatment values (28.4 ± 12.5%). In 12 patients followed for 5 years, a significant reduction in rates of yearly decline in FEV1 (−1.4 ± 0.2 vs. 0.3 ± 0.4% predicted; P = 0.025) was observed. Analyses of 104 computed tomography scans showed a nonsignificant (P = 0.23) reduction in yearly rates of change of cyst scores (1.8 ± 0.2 vs. 0.3 ± 0.3%; P = 0.23) and lung texture features. Despite adverse events, most patients were able to continue sirolimus therapy. Conclusions: Sirolimus therapy slowed down lung function decline and increase in cystic lesions. Most patients were able to tolerate sirolimus therapy. PMID:25329516

  10. YEAR-TO-YEAR CHANGES IN LUNG FUNCTION IN INDIVIDUALS WITH CYSTIC FIBROSIS

    PubMed Central

    Liou, Theodore G.; Elkin, Eric P.; Pasta, David J.; Jacobs, Joan R.; Konstan, Michael W.; Morgan, Wayne J.; Wagener, Jeffrey S.

    2014-01-01

    Background We examined the year-to-year change in FEV1 for individuals and the overall cystic fibrosis population to better understand how individual trends may differ from population trends. Methods We calculated individual yearly changes using the largest annual FEV1 percent predicted (FEV1%) measurement in 20,644 patients (6–45 years old) included in the Epidemiologic Study of Cystic Fibrosis. We calculated yearly population changes using age-specific medians. Results FEV1% predicted decreased 1–3 points per year for individuals, with maximal decreases in 14–15 year olds. Population changes agreed with individual changes up to age 15; however after age 30, yearly population change approximated zero while individual FEV1% predicted decreases were 1–2 points per year. Conclusions Adolescents have the greatest FEV1% predicted decreases; however. loss of FEV1 is a persistent risk in 6–45 year old CF patients. Recognizing individual year-to-year changes may improve patient-specific care and may suggest new methods for measuring program quality. PMID:20471331

  11. Antihistamine medication may alleviate negative effects of prenatal exposure to polycyclic aromatic hydrocarbons (PAH) on lung function in children. Birth cohort prospective study.

    PubMed

    Jedrychowski, Wieslaw A; Perera, Frederica P; Maugeri, Umberto; Majewska, Renata; Spengler, Jack; Mroz, Elzbieta; Flak, Elzbieta; Klimaszewska-Rembiasz, Maria; Camman, David

    2015-05-01

    The main purpose of the present study was to test the hypothesis that the depressed lung growth attributable to prenatal exposure to polycyclic aromatic hydrocarbons (PAH) may be modified by the intake of antihistamine medications. Individual prenatal PAH exposure was assessed by personal air monitoring in 176 children who were followed over nine years, in the course of which outdoor residential air monitoring, allergic skin tests for indoor allergens, lung function tests (FVC, FEV(1), FEV(05), and FEF(25-75)) were performed. The analysis with the General Estimated Equation (GEE) showed no association between prenatal PAH exposure and lung function in the group of children who were reported to be antihistamine users. However, in the group of antihistamine non-users all lung function tests except for FEF(25-75) were significantly and inversely associated with prenatal airborne PAH exposure. The results of the study suggest that the intake of antihistamine medications in early childhood may inhibit the negative effect of fetal PAH exposure on lung growth and provides additional indirect evidence for the hypothesis that lung alterations in young children resulting from PAH exposure may be caused by the allergic inflammation within lung. © 2014 Wiley Periodicals, Inc.

  12. Reduced Lung Function and Cerebral Small Vessel Disease in Japanese Men: the Shiga Epidemiological Study of Subclinical Atherosclerosis (SESSA).

    PubMed

    Seto-Yukimura, Ruriko; Ogawa, Emiko; Hisamatsu, Takashi; Torii, Sayuki; Shiino, Akihiko; Nozaki, Kazuhiko; Fujiyoshi, Akira; Miura, Katsuyuki; Nakano, Yasutaka; Ueshima, Hirotsugu

    2018-02-16

    We aimed to investigate the association between reduced lung function and cerebral small vessel diseases via cranial magnetic resonance imaging (MRI) in the cross-sectional study of the general Japanese population. We recruited participants aged ≥40 years from the general population of a single city in Japan. We clarified the comorbidities and treatments, smoking habits, second-hand smoke exposure, current alcohol consumption, education level, exercise habits, and occupation. The pulmonary function test was performed to assess the forced expiratory volume in 1 second (FEV 1 ) % predicted and forced vital capacity (FVC) % predicted values. Cranial MRI was performed to evaluate the white matter lesions (WMLs) and lacunar infarcts. We examined the association of the WMLs and lacunar infarcts with a 1-standard deviation (SD) lower in the FEV 1 % predicted and FVC % predicted, on the basis of the smoking status. A total of 473 men were examined. The association of WMLs and lacunar infarcts with the spirometry-based indices were significant only in never smokers. The association between lung function impairment and cerebral small vessel disease did not change after further adjusting for second-hand smoke exposure. In a community-based sample of Japanese men, we found an association between reduced lung function and WMLs and lacunar infarcts in never smokers.

  13. Influence of emphysema distribution on pulmonary function parameters in COPD patients

    PubMed Central

    Bastos, Helder Novais e; Neves, Inês; Redondo, Margarida; Cunha, Rui; Pereira, José Miguel; Magalhães, Adriana; Fernandes, Gabriela

    2015-01-01

    ABSTRACT OBJECTIVE: To evaluate the impact that the distribution of emphysema has on clinical and functional severity in patients with COPD. METHODS: The distribution of the emphysema was analyzed in COPD patients, who were classified according to a 5-point visual classification system of lung CT findings. We assessed the influence of emphysema distribution type on the clinical and functional presentation of COPD. We also evaluated hypoxemia after the six-minute walk test (6MWT) and determined the six-minute walk distance (6MWD). RESULTS: Eighty-six patients were included. The mean age was 65.2 ± 12.2 years, 91.9% were male, and all but one were smokers (mean smoking history, 62.7 ± 38.4 pack-years). The emphysema distribution was categorized as obviously upper lung-predominant (type 1), in 36.0% of the patients; slightly upper lung-predominant (type 2), in 25.6%; homogeneous between the upper and lower lung (type 3), in 16.3%; and slightly lower lung-predominant (type 4), in 22.1%. Type 2 emphysema distribution was associated with lower FEV1, FVC, FEV1/FVC ratio, and DLCO. In comparison with the type 1 patients, the type 4 patients were more likely to have an FEV1 < 65% of the predicted value (OR = 6.91, 95% CI: 1.43-33.45; p = 0.016), a 6MWD < 350 m (OR = 6.36, 95% CI: 1.26-32.18; p = 0.025), and post-6MWT hypoxemia (OR = 32.66, 95% CI: 3.26-326.84; p = 0.003). The type 3 patients had a higher RV/TLC ratio, although the difference was not significant. CONCLUSIONS: The severity of COPD appears to be greater in type 4 patients, and type 3 patients tend to have greater hyperinflation. The distribution of emphysema could have a major impact on functional parameters and should be considered in the evaluation of COPD patients. PMID:26785956

  14. LINKING LUNG AIRWAY STRUCTURE TO PULMONARY FUNCTION VIA COMPOSITE BRIDGE REGRESSION

    PubMed Central

    Chen, Kun; Hoffman, Eric A.; Seetharaman, Indu; Jiao, Feiran; Lin, Ching-Long; Chan, Kung-Sik

    2017-01-01

    The human lung airway is a complex inverted tree-like structure. Detailed airway measurements can be extracted from MDCT-scanned lung images, such as segmental wall thickness, airway diameter, parent-child branch angles, etc. The wealth of lung airway data provides a unique opportunity for advancing our understanding of the fundamental structure-function relationships within the lung. An important problem is to construct and identify important lung airway features in normal subjects and connect these to standardized pulmonary function test results such as FEV1%. Among other things, the problem is complicated by the fact that a particular airway feature may be an important (relevant) predictor only when it pertains to segments of certain generations. Thus, the key is an efficient, consistent method for simultaneously conducting group selection (lung airway feature types) and within-group variable selection (airway generations), i.e., bi-level selection. Here we streamline a comprehensive procedure to process the lung airway data via imputation, normalization, transformation and groupwise principal component analysis, and then adopt a new composite penalized regression approach for conducting bi-level feature selection. As a prototype of composite penalization, the proposed composite bridge regression method is shown to admit an efficient algorithm, enjoy bi-level oracle properties, and outperform several existing methods. We analyze the MDCT lung image data from a cohort of 132 subjects with normal lung function. Our results show that, lung function in terms of FEV1% is promoted by having a less dense and more homogeneous lung comprising an airway whose segments enjoy more heterogeneity in wall thicknesses, larger mean diameters, lumen areas and branch angles. These data hold the potential of defining more accurately the “normal” subject population with borderline atypical lung functions that are clearly influenced by many genetic and environmental factors. PMID:28280520

  15. Obesity in children with poorly controlled asthma: Sex differences.

    PubMed

    Lang, Jason E; Holbrook, Janet T; Wise, Robert A; Dixon, Anne E; Teague, W Gerald; Wei, Christine Y; Irvin, Charles G; Shade, David; Lima, John J

    2013-09-01

    Obesity increases asthma risk, and may alter asthma severity. In adults, sex appears to modify the effect of obesity on asthma. Among children, the effect of sex on the relationship between obesity and asthma severity remains less clear, particularly when considering race. To determine how obesity affects disease characteristics in a diverse cohort of children with poorly controlled asthma, and if obesity effects are altered by sex. We analyzed 306 children between 6 and 17 years of age with poorly controlled asthma enrolled in a 6-month trial assessing lansoprazole for asthma control. In this secondary analysis, we determined associations between obesity and symptom severity, spirometry, exacerbation risk, airway biomarkers, bronchial reactivity, and airflow perception. We used both a multivariate linear regression and longitudinal mixed-effect model to determine if obesity interacted with sex to affect asthma severity. Regardless of sex, BMI >95th percentile did not affect asthma control, exacerbation risk or airway biomarkers. Sex changed the effect of obesity on lung function (sex × obesity FEV1%, interaction P-value < 0.01, sex × obesity FEV1/FVC, interaction P-value = 0.03). Obese males had significantly worse airflow obstruction compared to non-obese males, while in females there was no obesity effect on airflow obstruction. In females, obesity was associated with significantly greater FEV1 and FVC, and a trend toward reduced airway reactivity. Obesity did not affect asthma control, airway markers or disease stability; however obesity did affect lung function in a sex-dependent manner. In males, obesity associated with reduced FEV1/FVC, and in females, obesity associated with substantially improved lung function. Copyright © 2012 Wiley Periodicals, Inc.

  16. CT Metrics of Airway Disease and Emphysema in Severe COPD

    PubMed Central

    Kim, Woo Jin; Silverman, Edwin K.; Hoffman, Eric; Criner, Gerard J.; Mosenifar, Zab; Sciurba, Frank C.; Make, Barry J.; Carey, Vincent; Estépar, Raúl San José; Diaz, Alejandro; Reilly, John J.; Martinez, Fernando J.; Washko, George R.

    2009-01-01

    Background: CT scan measures of emphysema and airway disease have been correlated with lung function in cohorts of subjects with a range of COPD severity. The contribution of CT scan-assessed airway disease to objective measures of lung function and respiratory symptoms such as dyspnea in severe emphysema is less clear. Methods: Using data from 338 subjects in the National Emphysema Treatment Trial (NETT) Genetics Ancillary Study, densitometric measures of emphysema using a threshold of −950 Hounsfield units (%LAA-950) and airway wall phenotypes of the wall thickness (WT) and the square root of wall area (SRWA) of a 10-mm luminal perimeter airway were calculated for each subject. Linear regression analysis was performed for outcome variables FEV1 and percent predicted value of FEV1 with CT scan measures of emphysema and airway disease. Results: In univariate analysis, there were significant negative correlations between %LAA-950 and both the WT (r = −0.28, p = 0.0001) and SRWA (r = −0.19, p = 0.0008). Airway wall thickness was weakly but significantly correlated with postbronchodilator FEV1% predicted (R = −0.12, p = 0.02). Multivariate analysis showed significant associations between either WT or SRWA (β = −5.2, p = 0.009; β = −2.6, p = 0.008, respectively) and %LAA-950 (β = −10.6, p = 0.03) with the postbronchodilator FEV1% predicted. Male subjects exhibited significantly thicker airway wall phenotypes (p = 0.007 for WT and p = 0.0006 for SRWA). Conclusions: Airway disease and emphysema detected by CT scanning are inversely related in patients with severe COPD. Airway wall phenotypes were influenced by gender and associated with lung function in subjects with severe emphysema. PMID:19411295

  17. Molecular mechanisms underlying variations in lung function: a systems genetics analysis

    PubMed Central

    Obeidat, Ma’en; Hao, Ke; Bossé, Yohan; Nickle, David C; Nie, Yunlong; Postma, Dirkje S; Laviolette, Michel; Sandford, Andrew J; Daley, Denise D; Hogg, James C; Elliott, W Mark; Fishbane, Nick; Timens, Wim; Hysi, Pirro G; Kaprio, Jaakko; Wilson, James F; Hui, Jennie; Rawal, Rajesh; Schulz, Holger; Stubbe, Beate; Hayward, Caroline; Polasek, Ozren; Järvelin, Marjo-Riitta; Zhao, Jing Hua; Jarvis, Deborah; Kähönen, Mika; Franceschini, Nora; North, Kari E; Loth, Daan W; Brusselle, Guy G; Smith, Albert Vernon; Gudnason, Vilmundur; Bartz, Traci M; Wilk, Jemma B; O’Connor, George T; Cassano, Patricia A; Tang, Wenbo; Wain, Louise V; Artigas, María Soler; Gharib, Sina A; Strachan, David P; Sin, Don D; Tobin, Martin D; London, Stephanie J; Hall, Ian P; Paré, Peter D

    2016-01-01

    Summary Background Lung function measures reflect the physiological state of the lung, and are essential to the diagnosis of chronic obstructive pulmonary disease (COPD). The SpiroMeta-CHARGE consortium undertook the largest genome-wide association study (GWAS) so far (n=48 201) for forced expiratory volume in 1 s (FEV1) and the ratio of FEV1 to forced vital capacity (FEV1/FVC) in the general population. The lung expression quantitative trait loci (eQTLs) study mapped the genetic architecture of gene expression in lung tissue from 1111 individuals. We used a systems genetics approach to identify single nucleotide polymorphisms (SNPs) associated with lung function that act as eQTLs and change the level of expression of their target genes in lung tissue; termed eSNPs. Methods The SpiroMeta-CHARGE GWAS results were integrated with lung eQTLs to map eSNPs and the genes and pathways underlying the associations in lung tissue. For comparison, a similar analysis was done in peripheral blood. The lung mRNA expression levels of the eSNP-regulated genes were tested for associations with lung function measures in 727 individuals. Additional analyses identified the pleiotropic effects of eSNPs from the published GWAS catalogue, and mapped enrichment in regulatory regions from the ENCODE project. Finally, the Connectivity Map database was used to identify potential therapeutics in silico that could reverse the COPD lung tissue gene signature. Findings SNPs associated with lung function measures were more likely to be eQTLs and vice versa. The integration mapped the specific genes underlying the GWAS signals in lung tissue. The eSNP-regulated genes were enriched for developmental and inflammatory pathways; by comparison, SNPs associated with lung function that were eQTLs in blood, but not in lung, were only involved in inflammatory pathways. Lung function eSNPs were enriched for regulatory elements and were over-represented among genes showing differential expression during fetal lung development. An mRNA gene expression signature for COPD was identified in lung tissue and compared with the Connectivity Map. This in-silico drug repurposing approach suggested several compounds that reverse the COPD gene expression signature, including a nicotine receptor antagonist. These findings represent novel therapeutic pathways for COPD. Interpretation The system genetics approach identified lung tissue genes driving the variation in lung function and susceptibility to COPD. The identification of these genes and the pathways in which they are enriched is essential to understand the pathophysiology of airway obstruction and to identify novel therapeutic targets and biomarkers for COPD, including drugs that reverse the COPD gene signature in silico. Funding The research reported in this article was not specifically funded by any agency. See Acknowledgments for a full list of funders of the lung eQTL study and the Spiro-Meta CHARGE GWAS. PMID:26404118

  18. Early Childhood Risk Factors for Decreased FEV1 at Age Six to Seven Years in Young Children with Cystic Fibrosis.

    PubMed

    Sanders, Don B; Emerson, Julia; Ren, Clement L; Schechter, Michael S; Gibson, Ronald L; Morgan, Wayne; Rosenfeld, Margaret

    2015-08-01

    There are limited objective measures of the severity of lung disease before children are able to routinely perform spirometry, generally at age 6 years. Identifying risk factors for reduced lung function at age 6 provides opportunities to intervene and slow the progression of cystic fibrosis (CF) lung disease. To evaluate early childhood predictors of lung function at age 6-7 in a large U.S. CF cohort in the current era of widespread early eradication therapy for Pseudomonas aeruginosa (P. aeruginosa). Participants were children with CF enrolled before age 4 in the Early Pseudomonas Infection Control (EPIC) Observational Study, a multicenter, longitudinal study that enrolled P. aeruginosa-negative children not exceeding 12 years of age. Linear regression was used to estimate the association between potential early childhood risk factors and the best FEV1% predicted at age 6-7 years. Four hundred and eighty-four children (of 1,797 enrolled in the EPIC Observational Study) met the eligibility criteria for this analysis. Mean (SD) age at enrollment was 2.0 (1.3) years. In a multivariable model adjusted for age at enrollment, the following risk factors were significantly associated with lower mean (95% confidence interval) FEV1% predicted at age 6-7: weight percentile less than 10% during the year of enrollment (-5.3 [-9.1, -1.5]), P. aeruginosa positive during the year of enrollment (-2.8 [-5.7, 0.0]), crackles or wheeze during the year of enrollment (-5.7 [-9.4, -1.9]), mother's education of high school or less (-4.2 [-7.3, -1.2]), and mother smoked during pregnancy (-4.4 [-8.8, 0.1]). In this large U.S. cohort, we identified several early childhood risk factors for lower FEV1 at age 6-7 years, most of which are modifiable. Clinical trial registered with www.clinicaltrials.gov (NCT00097773).

  19. PAI-1 gain-of-function genotype, factors increasing PAI-1 levels, and airway obstruction: The GALA II Cohort.

    PubMed

    Sherenian, M G; Cho, S H; Levin, A; Min, J-Y; Oh, S S; Hu, D; Galanter, J; Sen, S; Huntsman, S; Eng, C; Rodriguez-Santana, J R; Serebrisky, D; Avila, P C; Kalhan, R; Smith, L J; Borrell, L N; Seibold, M A; Keoki Williams, L; Burchard, E G; Kumar, R

    2017-09-01

    PAI-1 gain-of-function variants promote airway fibrosis and are associated with asthma and with worse lung function in subjects with asthma. We sought to determine whether the association of a gain-of-function polymorphism in plasminogen activator inhibitor-1 (PAI-1) with airway obstruction is modified by asthma status, and whether any genotype effect persists after accounting for common exposures that increase PAI-1 level. We studied 2070 Latino children (8-21y) with genotypic and pulmonary function data from the GALA II cohort. We estimated the relationship of the PAI-1 risk allele with FEV1/FVC by multivariate linear regression, stratified by asthma status. We examined the association of the polymorphism with asthma and airway obstruction within asthmatics via multivariate logistic regression. We replicated associations in the SAPPHIRE cohort of African Americans (n=1056). Secondary analysis included the effect of the at-risk polymorphism on postbronchodilator lung function. There was an interaction between asthma status and the PAI-1 polymorphism on FEV 1 /FVC (P=.03). The gain-of-function variants, genotypes (AA/AG), were associated with lower FEV 1 /FVC in subjects with asthma (β=-1.25, CI: -2.14,-0.35, P=.006), but not in controls. Subjects with asthma and the AA/AG genotypes had a 5% decrease in FEV 1 /FVC (P<.001). In asthmatics, the risk genotype (AA/AG) was associated with a 39% increase in risk of clinically relevant airway obstruction (OR=1.39, CI: 1.01, 1.92, P=.04). These associations persisted after exclusion of factors that increase PAI-1 including tobacco exposure and obesity. The decrease in the FEV 1 /FVC ratio associated with the risk genotype was modified by asthma status. The genotype increased the odds of airway obstruction by 75% within asthmatics only. As exposures known to increase PAI-1 levels did not mitigate this association, PAI-1 may contribute to airway obstruction in the context of chronic asthmatic airway inflammation. © 2017 John Wiley & Sons Ltd.

  20. Genome-wide association and network analysis of lung function in the Framingham Heart Study.

    PubMed

    Liao, Shu-Yi; Lin, Xihong; Christiani, David C

    2014-09-01

    Single nucleotide polymorphisms have been found to be associated with pulmonary function using genome-wide association studies. However, lung function is a complex trait that is likely to be influenced by multiple gene-gene interactions besides individual genes. Our goal is to build a cellular network to explore the relationship between pulmonary function and genotypes by combining SNP level and network analyses using longitudinal lung function data from the Framingham Heart Study. We analyzed 2,698 genotyped participants from the Offspring cohort that had an average of 3.35 spirometry measurements per person for a mean length of 13 years. Repeated forced expiratory volume in one second (FEV1 ) and the ratio of FEV1 to forced vital capacity (FVC) were used as outcomes. Data were analyzed using linear-mixed models for the association between lung function and alleles by accounting for the correlation among repeated measures over time within the same subject and within-family correlation. Network analyses were performed using dmGWAS and validated with data from the Third Generation cohort. Analyses identified SMAD3, TGFBR2, CD44, CTGF, VCAN, CTNNB1, SCGB1A1, PDE4D, NRG1, EPHB1, and LYN as contributors to pulmonary function. Most of these genes were novel that were not found previously using solely SNP-level analysis. These novel genes are involving the transforming growth factor beta (TGFB)-SMAD pathway, Wnt/beta-catenin pathway, etc. Therefore, combining SNP-level and network analyses using longitudinal lung function data is a useful alternative strategy to identify risk genes. © 2014 WILEY PERIODICALS, INC.

  1. CT-derived Biomechanical Metrics Improve Agreement Between Spirometry and Emphysema

    PubMed Central

    Bhatt, Surya P.; Bodduluri, Sandeep; Newell, John D.; Hoffman, Eric A.; Sieren, Jessica C.; Han, Meilan K.; Dransfield, Mark T.; Reinhardt, Joseph M.

    2016-01-01

    Rationale and Objectives Many COPD patients have marked discordance between FEV1 and degree of emphysema on CT. Biomechanical differences between these patients have not been studied. We aimed to identify reasons for the discordance between CT and spirometry in some patients with COPD. Materials and Methods Subjects with GOLD stage I–IV from a large multicenter study (COPDGene) were arranged by percentiles of %predicted FEV1 and emphysema on CT. Three categories were created using differences in percentiles: Catspir with predominant airflow obstruction/minimal emphysema, CatCT with predominant emphysema/minimal airflow obstruction, and Catmatched with matched FEV1 and emphysema. Image registration was used to derive Jacobian determinants, a measure of lung elasticity, anisotropy and strain tensors, to assess biomechanical differences between groups. Regression models were created with the above categories as outcome variable, adjusting for demographics, scanner type, quantitative CT-derived emphysema, gas trapping, and airway thickness (Model 1), and after adding biomechanical CT metrics (Model 2). Results Jacobian determinants, anisotropy and strain tensors were strongly associated with FEV1. With Catmatched as control, Model 2 predicted Catspir and CatCT better than Model 1 (Akaike Information Criterion, AIC 255.8 vs. 320.8). In addition to demographics, the strongest independent predictors of FEV1 were Jacobian mean (β= 1.60,95%CI = 1.16 to 1.98; p<0.001), coefficient of variation (CV) of Jacobian (β= 1.45,95%CI = 0.86 to 2.03; p<0.001) and CV strain (β= 1.82,95%CI = 0.68 to 2.95; p = 0.001). CVs of Jacobian and strain are both potential markers of biomechanical lung heterogeneity. Conclusions CT-derived measures of lung mechanics improve the link between quantitative CT and spirometry, offering the potential for new insights into the linkage between regional parenchymal destruction and global decrement in lung function in COPD patients. PMID:27055745

  2. Tiotropium in Early-Stage Chronic Obstructive Pulmonary Disease.

    PubMed

    Zhou, Yumin; Zhong, Nan-Shan; Li, Xiaochen; Chen, Shuyun; Zheng, Jinping; Zhao, Dongxing; Yao, Weimin; Zhi, Rongchang; Wei, Liping; He, Bingwen; Zhang, Xiangyan; Yang, Changli; Li, Ying; Li, Fenglei; Du, Juan; Gui, Jianping; Hu, Bin; Bai, Chunxue; Huang, Ping; Chen, Gang; Xu, Yongjian; Wang, Changzheng; Liang, Biao; Li, Yinhuan; Hu, Guoping; Tan, Hui; Ye, Xianwei; Ma, Xitao; Chen, Yan; Hu, Xiwei; Tian, Jia; Zhu, Xiaodan; Shi, Zhe; Du, Xiufang; Li, Minjing; Liu, Shengming; Yu, Ronghuan; Zhao, Jianping; Ma, Qianli; Xie, Canmao; Li, Xiongbin; Chen, Tao; Lin, Yingxiang; Zeng, Lizhen; Ye, Changxiu; Ye, Weishu; Luo, Xiangwen; Zeng, Lingshan; Yu, Shuqing; Guan, Wei-Jie; Ran, Pixin

    2017-09-07

    Patients with mild or moderate chronic obstructive pulmonary disease (COPD) rarely receive medications, because they have few symptoms. We hypothesized that long-term use of tiotropium would improve lung function and ameliorate the decline in lung function in patients with mild or moderate COPD. In a multicenter, randomized, double-blind, placebo-controlled trial that was conducted in China, we randomly assigned 841 patients with COPD of Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage 1 (mild) or 2 (moderate) severity to receive a once-daily inhaled dose (18 μg) of tiotropium (419 patients) or matching placebo (422) for 2 years. The primary end point was the between-group difference in the change from baseline to 24 months in the forced expiratory volume in 1 second (FEV 1 ) before bronchodilator use. Secondary end points included the between-group difference in the change from baseline to 24 months in the FEV 1 after bronchodilator use and the between-group difference in the annual decline in the FEV 1 before and after bronchodilator use from day 30 to month 24. Of 841 patients who underwent randomization, 388 patients in the tiotropium group and 383 in the placebo group were included in the full analysis set. The FEV 1 in patients who received tiotropium was higher than in those who received placebo throughout the trial (ranges of mean differences, 127 to 169 ml before bronchodilator use and 71 to 133 ml after bronchodilator use; P<0.001 for all comparisons). There was no significant amelioration of the mean (±SE) annual decline in the FEV 1 before bronchodilator use: the decline was 38±6 ml per year in the tiotropium group and 53±6 ml per year in the placebo group (difference, 15 ml per year; 95% confidence interval [CI], -1 to 31; P=0.06). In contrast, the annual decline in the FEV 1 after bronchodilator use was significantly less in the tiotropium group than in the placebo group (29±5 ml per year vs. 51±6 ml per year; difference, 22 ml per year [95% CI, 6 to 37]; P=0.006). The incidence of adverse events was generally similar in the two groups. Tiotropium resulted in a higher FEV 1 than placebo at 24 months and ameliorated the annual decline in the FEV 1 after bronchodilator use in patients with COPD of GOLD stage 1 or 2. (Funded by Boehringer Ingelheim and others; Tie-COPD ClinicalTrials.gov number, NCT01455129 .).

  3. Longitudinal lung function decline and wood dust exposure in the furniture industry.

    PubMed

    Jacobsen, G; Schlünssen, V; Schaumburg, I; Taudorf, E; Sigsgaard, T

    2008-02-01

    The aim of the present study was to investigate the relationship between change in lung function and cumulative exposure to wood dust. In total, 1,112 woodworkers (927 males, 185 females) and 235 reference workers (104 males, 185 females) participated in a 6-yr longitudinal study. Forced expiratory volume in one second (FEV(1)), forced vital capacity (FVC), height and weight were measured, and questionnaire data on respiratory symptoms, wood dust exposure and smoking habits were collected. Cumulative inhalable wood dust exposure was assessed using a study-specific job exposure matrix and exposure time. The median (range) for cumulative wood dust exposure was 3.75 (0-7.55) mg x year x m(-3). A dose-response relationship between cumulative wood dust exposure and percent annual decrease in FEV(1) was suggested for female workers. This was confirmed in a linear regression model adjusted for confounders, including smoking, height and age. An additional difference of -14.50 mL x yr(-1) and -27.97 mL x yr(-1) was revealed for females exposed to 3.75-4.71 mg x yr x m(-3) or to >4.71 mg x yr x m(-3), respectively, compared with non-/low-exposed females. For females, a positive trend between wood dust exposure and the cumulative incidence proportion of FEV(1)/FVC <70% was suggested. In conclusion, in the present low-exposed cohort, female woodworkers had an accelerated decline in lung function, which may be clinically relevant.

  4. Intrauterine and early postnatal exposure to outdoor air pollution and lung function at preschool age.

    PubMed

    Morales, Eva; Garcia-Esteban, Raquel; de la Cruz, Oscar Asensio; Basterrechea, Mikel; Lertxundi, Aitana; de Dicastillo, Maria D Martinez López; Zabaleta, Carlos; Sunyer, Jordi

    2015-01-01

    Effects of prenatal and postnatal exposure to air pollution on lung function at preschool age remain unexplored. We examined the association of exposure to air pollution during specific trimesters of pregnancy and postnatal life with lung function in preschoolers. Lung function was assessed with spirometry in preschoolers aged 4.5 years (n=620) participating in the INfancia y Medio Ambiente (INMA) cohort. Temporally adjusted land use regression (LUR) models were applied to estimate individual residential exposures to benzene and nitrogen dioxide (NO₂) during specific trimesters of pregnancy and early postnatal life (the first year of life). Recent and current (1 year and 1 week before lung function testing, respectively) exposures to NO₂ and nitrogen oxides (NOx) were also assessed. Exposure to higher levels of benzene and NO₂ during pregnancy was associated with reduced lung function. FEV1 estimates for an IQR increase in exposures during the second trimester of pregnancy were -18.4 mL, 95% CI -34.8 to -2.1 for benzene and -28.0 mL, 95% CI -52.9 to -3.2 for NO₂. Relative risk (RR) of low lung function (<80% of predicted FEV1) for an IQR increase in benzene and NO₂ during the second trimester of pregnancy were 1.22, 95% CI 1.02 to 1.46 and 1.30, 95% CI 0.97 to 1.76, respectively. Associations for early postnatal, recent and current exposures were not statistically significant. Stronger associations appeared among allergic children and those of lower social class. Prenatal exposure to residential traffic-related air pollution may result in long-term lung function deficits at preschool age. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Body composition and lung function in cystic fibrosis and their association with adiposity and normal-weight obesity.

    PubMed

    Alvarez, Jessica A; Ziegler, Thomas R; Millson, Erin C; Stecenko, Arlene A

    2016-04-01

    This study aimed to evaluate the relationship between lung function and body composition in cystic fibrosis (CF) and examine the presence of normal-weight obesity (NWO), a high body fat percentage with a normal body mass index (BMI), in this population. In a pilot, cross-sectional study, 32 subjects with CF and a reference group of 20 adults without CF underwent body composition analysis with air displacement plethysmography. NWO was defined as a BMI <25 kg/m(2) and body fat >30% (for women) or >23% (for men). Lung function in subjects with CF was determined by the percentage of predicted forced expiratory volume in 1 s (FEV1% predicted). Despite lower BMI and fat-free mass index (P < 0.01), fat mass index and percent body fat did not differ between subjects with CF and the reference group. Among subjects with CF, FEV1% predicted was positively associated with fat-free mass index (β = 6.31 ± 2.93, P = 0.04) and inversely associated with fat mass index (β = -6.44 ± 2.93, P = 0.04), after adjusting for age, sex, and BMI. Ten subjects with CF (31%) had NWO, which corresponded with lower fat-free mass index and FEV1% predicted compared with overweight subjects (P = 0.006 and 0.004, respectively). Excess adiposity, particularly in the form of NWO, was inversely associated with lung function in CF. Larger prospective studies should be undertaken to confirm these findings and determine the long-term metabolic and clinical consequences of excess adiposity in CF. As the lifespan of individuals with CF increases, nutrition screening protocols, which primarily rely on BMI, may require reassessment. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Transfer factor, lung volumes, resistance and ventilation distribution in healthy adults.

    PubMed

    Verbanck, Sylvia; Van Muylem, Alain; Schuermans, Daniel; Bautmans, Ivan; Thompson, Bruce; Vincken, Walter

    2016-01-01

    Monitoring of chronic lung disease requires reference values of lung function indices, including putative markers of small airway function, spanning a wide age range.We measured spirometry, transfer factor of the lung for carbon monoxide (TLCO), static lung volume, resistance and ventilation distribution in a healthy population, studying at least 20 subjects per sex and per decade between the ages of 20 and 80 years.With respect to the Global Lung Function Initiative reference data, our subjects had average z-scores for forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC of -0.12, 0.04 and -0.32, respectively. Reference equations were obtained which could account for a potential dependence of index variability on age and height. This was done for (but not limited to) indices that are pertinent to asthma and chronic obstructive pulmonary disease studies: forced expired volume in 6 s, forced expiratory flow, TLCO, specific airway conductance, residual volume (RV)/total lung capacity (TLC), and ventilation heterogeneity in acinar and conductive lung zones.Deterioration in acinar ventilation heterogeneity and lung clearance index with age were more marked beyond 60 years, and conductive ventilation heterogeneity showed the greatest increase in variability with age. The most clinically relevant deviation from published reference values concerned RV/TLC values, which were considerably smaller than American Thoracic Society/European Respiratory Society-endorsed reference values. Copyright ©ERS 2016.

  7. The relationship between respiratory system impedance and lung function in asthmatics: A prospective observational study.

    PubMed

    Kamada, Takahiro; Kaneko, Masahiro; Tomioka, Hiromi

    2017-05-01

    The aim was to elucidate the relationship between the annual changes in respiratory system impedance, measured by FOT, and lung function tests in patients with asthma. Between March 2011 and March 2012, asthma outpatients who attended Kobe City Medical Center West Hospital were recruited. Lung function tests, FOT were conducted every 6 months until March 2016. The relationships between annual parameter changes were evaluated. Sixty-four patients were completed this study. The median follow-up period was 55 months. At enrollment, although resistance showed no relationship with forced expiratory volume in one second (%FEV 1 ), the reactance was moderately correlated with X5 (r=0.524, r 2 =0.275, <0.001), Fres (r=-0.498, r 2 =0.248, <0.001) and ALX (r=-0.416, r 2 =0.173, p=<0.001). By contrast, the annual resistance change at 5Hz (R5) was highly and significantly associated with%FEV 1 change (r=-0.564, r 2 =0.318, p<0.001). Longitudinal changes in airway resistance and reactance measured by FOT might be useful for the assessment of lung function in patients with asthma. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Are Lung Disease and Function Related to Age-related Macular Degeneration?

    PubMed Central

    Moorthy, Sonia; Cheung, Ning; Klein, Ronald; Shahar, E; Wong, Tien Y

    2010-01-01

    Purpose To describe the relationship of lung disease and function with early age-related macular degeneration (AMD) in a population-based study. Design A population-based, cross-sectional study of 12,596 middle-aged participants from the Atherosclerosis Risk in Communities Study. Methods Lung function was assessed by spirometry. Physician diagnosis of asthma and lung disease was ascertained from a standardized questionnaire. AMD signs were graded from fundus photographs according to the Wisconsin grading protocol. Results Of our study population, 587 (4.7%) had early AMD, 638 (5.1%) had asthma and 581 (4.6%) had lung disease. After adjusting for age, gender, smoking and hypertension, each litre increase in predicted forced expiratory volume in one second (FEV1) (odds ratio [OR]: 1.27; 95% confidence interval [CI]: 0.89, 1.80), forced vital capacity (FVC) (OR 1.18; 95% CI: 0.93, 1.51) and peak expiratory flow rate (OR 1.12; 95% CI: 0.95, 1.33) were not significantly associated with early AMD. FEV1/FVC ratio (second quartile OR 1.61; 95%CI 0.88–2.93, third quartile OR 1.65; CI 0.90–3.03, fourth quartile OR 1.28; 95%CI 0.68–2.40) was not significantly associated with early AMD. Similarly, asthma (OR 1.06; 95% CI: 0.86, 1.27) and other lung diseases (OR 1.08; 95% CI: 0.90, 1.29) were not associated with early AMD. Conclusion Our data do not support a cross-sectional association between lung disease and risk of early AMD. PMID:21168814

  9. α1-Proteinase inhibitor (human) in the treatment of hereditary emphysema secondary to α1-antitrypsin deficiency: number and costs of years of life gained.

    PubMed

    Sclar, David Alexander; Evans, Marc A; Robison, Linda M; Skaer, Tracy L

    2012-05-01

    α(1)-Antitrypsin deficiency (α-ATD) is a disorder inherited in an autosomal recessive pattern, with co-dominant alleles known as the protease inhibitor system (Pi). The main function of α(1)-antitrypsin (α-AT) is to protect the lungs against a powerful elastase released from neutrophil leucocytes. α-ATD typically presents with a serum α-AT level of <50 mg/dL. In severe α-ATD, phenotype PiZZ, protection of the lungs is compromised, leading to an accelerated decline in forced expiratory volume in 1 second (FEV(1)). As a result, a patient may develop pulmonary emphysema of the panacinar type at a young age (third to fourth decades of life), with cigarette smoking being the most significant additional risk factor. It has been shown that weekly or monthly infusion of human α-AT is effective in raising serum α-AT levels to desired levels (>80 mg/dL), with few, if any, adverse effects. The present study was designed to discern the number of years of life gained, and the expense per year of life gained, associated with use of α-AT augmentation therapy (α(1)-proteinase inhibitor [human]), relative to 'no therapeutic intervention' in persons with α-ATD. Monte Carlo simulation (MCS) was used to: (i) estimate the number of years of life gained; and (ii) estimate the health service expenditures per year of life gained for persons receiving, or not receiving, α-AT augmentation therapy. MCS afforded a decision-analytical framework parameterized with both stochastic (random) and deterministic (fixed) components, and yielded a fiscal risk-profile for each simulated cohort of interest (eight total: by sex, smoking status [non-smoker; or past use (smoker)]; and use of α-AT augmentation therapy). The stochastic components employed in the present inquiry were: (i) age-specific body weight, and height; (ii) age-specific mortality; and (iii) the probability distribution for receipt of a lung transplant, as a function of FEV(1). The deterministic components employed in the present inquiry were: (i) age in years for the simulated cohort; (ii) outlays for α-AT augmentation therapy; (iii) health service expenditures associated with receipt of a lung transplant; (iv) annual decline in FEV(1); (v) percent predicted FEV(1); (vi) initiation of α-AT augmentation therapy as a function of percent predicted FEV(1); (vii) need for a lung transplant as a function of percent predicted FEV(1); (viii) annual rate of lung infection; and (ix) mortality as a function of percent predicted FEV(1). Results are reported from a payer perspective ($US, year of costing 2010). Receipt of α-AT augmentation therapy was associated with a significant increase (p < 0.05) in years of life gained, with female smokers gaining an estimated mean 7.14 years (cost per year: $US248 361 [95% CI 104 531, 392 190]); female non-smokers gained an estimated mean 9.19 years (cost per year: $US160 502 [95% CI 37 056, 283 947)]); male smokers gained an estimated mean 5.93 years (cost per year: $US142 250 [95% CI 48 467, 236 032]); and male non-smokers gained an estimated mean 10.60 years (cost per year: $US59 234 [95% CI 20 719, 97 548]). Use of α-AT augmentation therapy was associated with an increase in years of life gained by sex and history of tobacco use, and at a cost per year of life gained comparable to that of other evidenced-based interventions.

  10. Sixteen new lung function signals identified through 1000 Genomes Project reference panel imputation

    PubMed Central

    Artigas, María Soler; Wain, Louise V.; Miller, Suzanne; Kheirallah, Abdul Kader; Huffman, Jennifer E.; Ntalla, Ioanna; Shrine, Nick; Obeidat, Ma'en; Trochet, Holly; McArdle, Wendy L.; Alves, Alexessander Couto; Hui, Jennie; Zhao, Jing Hua; Joshi, Peter K.; Teumer, Alexander; Albrecht, Eva; Imboden, Medea; Rawal, Rajesh; Lopez, Lorna M.; Marten, Jonathan; Enroth, Stefan; Surakka, Ida; Polasek, Ozren; Lyytikäinen, Leo-Pekka; Granell, Raquel; Hysi, Pirro G.; Flexeder, Claudia; Mahajan, Anubha; Beilby, John; Bossé, Yohan; Brandsma, Corry-Anke; Campbell, Harry; Gieger, Christian; Gläser, Sven; González, Juan R.; Grallert, Harald; Hammond, Chris J.; Harris, Sarah E.; Hartikainen, Anna-Liisa; Heliövaara, Markku; Henderson, John; Hocking, Lynne; Horikoshi, Momoko; Hutri-Kähönen, Nina; Ingelsson, Erik; Johansson, Åsa; Kemp, John P.; Kolcic, Ivana; Kumar, Ashish; Lind, Lars; Melén, Erik; Musk, Arthur W.; Navarro, Pau; Nickle, David C.; Padmanabhan, Sandosh; Raitakari, Olli T.; Ried, Janina S.; Ripatti, Samuli; Schulz, Holger; Scott, Robert A.; Sin, Don D.; Starr, John M.; Deloukas, Panos; Hansell, Anna L.; Hubbard, Richard; Jackson, Victoria E.; Marchini, Jonathan; Pavord, Ian; Thomson, Neil C.; Zeggini, Eleftheria; Viñuela, Ana; Völzke, Henry; Wild, Sarah H.; Wright, Alan F.; Zemunik, Tatijana; Jarvis, Deborah L.; Spector, Tim D.; Evans, David M.; Lehtimäki, Terho; Vitart, Veronique; Kähönen, Mika; Gyllensten, Ulf; Rudan, Igor; Deary, Ian J.; Karrasch, Stefan; Probst-Hensch, Nicole M.; Heinrich, Joachim; Stubbe, Beate; Wilson, James F.; Wareham, Nicholas J.; James, Alan L.; Morris, Andrew P.; Jarvelin, Marjo-Riitta; Hayward, Caroline; Sayers, Ian; Strachan, David P.; Hall, Ian P.; Tobin, Martin D.

    2015-01-01

    Lung function measures are used in the diagnosis of chronic obstructive pulmonary disease. In 38,199 European ancestry individuals, we studied genome-wide association of forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC with 1000 Genomes Project (phase 1)-imputed genotypes and followed up top associations in 54,550 Europeans. We identify 14 novel loci (P<5 × 10−8) in or near ENSA, RNU5F-1, KCNS3, AK097794, ASTN2, LHX3, CCDC91, TBX3, TRIP11, RIN3, TEKT5, LTBP4, MN1 and AP1S2, and two novel signals at known loci NPNT and GPR126, providing a basis for new understanding of the genetic determinants of these traits and pulmonary diseases in which they are altered. PMID:26635082

  11. Association between Traffic Air Pollution and Reduced Forced Vital Capacity: A Study Using Personal Monitors for Outdoor Workers.

    PubMed

    Santos, Ubiratan Paula; Garcia, Maria Lúcia Siqueira Bueno; Braga, Alfésio Luís Ferreira; Pereira, Luiz Alberto Amador; Lin, Chin An; de André, Paulo Afonso; de André, Carmen Diva Saldiva; Singer, Julio da Motta; Saldiva, Paulo Hilário Nascimento

    2016-01-01

    The effects of outdoor air pollution on lung function in adults are still controversial. Evaluate the effects of exposure to different levels of traffic-generated PM2.5 on workers' lung functions in São Paulo, Brazil. To cover a wide range of exposures, 101 non-smoking workers from three occupations (taxi drivers, traffic controllers, and forest rangers) were selected for the study. After clinical evaluation, the participants were scheduled to attend four consecutive weekly visits in which they received a 24-hour personal PM2.5 sampler and had lung function tests measured on the following day. The association between the spirometric variables and the averaged PM2.5 levels was assessed using robust regression models adjusted for age, waist circumference, time at the job, daily work hours, diabetes or hypertension and former smoking habits. Relative to workers in the lowest exposed group (all measures < 25 μg/m3), those with the highest level of exposure (all measures > 39.6 μg/m3) showed a reduction of predicted FVC (-12.2%; CI 95%: [-20.0% to -4.4%]), a marginal reduction of predicted FEV1 (-9.1%; CI 95%: [-19.1% to 0.9%]) and an increase of predicted FEF25-75%/FVC (14.9%; CI 95%: [2.9% to 26.8%]) without changes of FEV1/FVC. Exposure to vehicular traffic air pollution is associated with a small but significant reduction of FVC without a reduction of FEV1/FVC.

  12. Ozone exposure, antioxidant genes, and lung function in an elderly cohort: VA Normative Aging Study

    PubMed Central

    Alexeeff, Stacey E.; Litonjua, Augusto A.; Wright, Robert O.; Baccarelli, Andrea; Suh, Helen; Sparrow, David; Vokonas, Pantel S.; Schwartz, Joel

    2008-01-01

    Background Ozone exposure is known to cause oxidative stress. We investigated the acute effects of ozone (O3) on lung function in the elderly, a suspected risk group. We then investigated whether genetic polymorphisms of antioxidant genes (heme oxygenase-1 [HMOX1] and glutathione S-transferase pi [GSTP1]) modified these associations. Methods We studied 1,100 elderly men from the Normative Aging Study whose lung function (forced vital capacity [FVC] and forced expiratory volume in one second [FEV1]) was measured every 3 years from 1995–2005. We genotyped the GSTP1 Ile105Val and Ala114Val polymorphisms and the (GT)n repeat polymorphism in the HMOX1 promoter, classifying repeats as short (n<25) or long (n 25). Ambient O3 was measured continuously at locations in the Greater Boston area. We used mixed linear models, adjusting for known confounders. Results A 15 ppb increase in O3 during the previous 48 hours was associated with a 1.25% decrease in FEV1 (95% CI: −1.96%, −0.54%). This estimated effect was worsened with either the presence of a long (GT)n repeat in HMOX1 (−1.38%, 95% CI: −2.11%, −0.65) or the presence of an allele coding for Val105 in GSTP1 (−1.69%, 95% CI: −2.63%, −0.75). A stronger estimated effect of O3 on FEV1 was found in subjects carrying both the GSTP1 105Val variant and the HMOX1 long (GT)n repeat (−1.94%, 95% CI: −2.89%, −0.98%). Similar associations were also found between FVC and ozone exposure. Conclusions Our results suggest that ozone has an acute effect on lung function in the elderly, and the effects may be modified by the presence of specific polymorphisms in antioxidant genes. PMID:18524839

  13. Physiologic assessment before video thoracoscopic resection for lung cancer in patients with abnormal pulmonary function.

    PubMed

    Benattia, Amira; Debeaumont, David; Guyader, Vincent; Tardif, Catherine; Peillon, Christophe; Cuvelier, Antoine; Baste, Jean-Marc

    2016-06-01

    Impaired respiratory function may prevent curative surgery for patients with non-small cell lung cancer (NSCLC). Video-assisted thoracoscopic surgery (VATS) reduces postoperative morbility-mortality and could change preoperative assessment practices and therapeutic decisions. We evaluated the relation between preoperative pulmonary function tests and the occurrence of postoperative complications after VATS pulmonary resection in patients with abnormal pulmonary function. We included 106 consecutive patients with ≤80% predicted value of presurgical expiratory volume in one second (FEV1) and/or diffusing capacity of carbon monoxide (DLCO) and who underwent VATS pulmonary resection for NSCLC from a prospective surgical database. Patients (64±9.5 years) had lobectomy (n=91), segmentectomy (n=7), bilobectomy (n=4), or pneumonectomy (n=4). FEV1 and DLCO preoperative averages were 68%±21% and 60%±18%. Operative mortality was 1.89%. Only FEV1 was predictive of postoperative complications [odds ratio (OR), 0.96; 95% confidence interval (CI), 0.926-0.991, P=0.016], but there was no determinable threshold. Twenty-five patients underwent incremental exercise testing. Desaturations during exercise (OR, 0.462; 95% CI, 0.191-0.878, P=0.039) and heart rate (HR) response (OR, 0.953; 95% CI, 0.895-0.993, P=0.05) were associated with postoperative complications. FEV1 but not DLCO was a significant predictor of pulmonary complications after VATS pulmonary resection despite a low rate of severe morbidity. Incremental exercise testing seems more discriminating. Further investigation is required in a larger patient population to change current pre-operative threshold in a new era of minimally invasive surgery.

  14. Prenatal fine particulate exposure associated with reduced childhood lung function and nasal epithelia GSTP1 hypermethylation: Sex-specific effects.

    PubMed

    Lee, Alison G; Le Grand, Blake; Hsu, Hsiao-Hsien Leon; Chiu, Yueh-Hsiu Mathilda; Brennan, Kasey J; Bose, Sonali; Rosa, Maria José; Brunst, Kelly J; Kloog, Itai; Wilson, Ander; Schwartz, Joel; Morgan, Wayne; Coull, Brent A; Wright, Robert O; Baccarelli, Andrea A; Wright, Rosalind J

    2018-04-27

    In utero exposure to particulate matter with an aerodynamic diameter of less than 2.5 μm (PM 2.5 ) has been linked to child lung function. Overlapping evidence suggests that child sex and exposure timing may modify effects and associations may be mediated through glutathione S-transferase P1 (GSTP1) methylation. We prospectively examined associations among prenatal PM 2.5 exposure and child lung function and GSTP1 methylation in an urban pregnancy cohort study. We employed a validated satellite-based spatiotemporally resolved prediction model to estimate daily prenatal PM 2.5 exposure over gestation. We used Baysian distributed lag interaction models (BDLIMs) to identify sensitive windows for prenatal PM 2.5 exposure on child lung function and nasal epithelia GSTP1 methylation at age 7 years, and to examine effect modification by child sex. BDLIMs identified a sensitive window for prenatal PM 2.5 exposure at 35-40 weeks gestation [cumulative effect estimate (CEE) = - 0.10, 95%CI = - 0.19 to - 0.01, per μg/m 3 increase in PM 2.5 ] and at 36-40 weeks (CEE = - 0.12, 95%CI = - 0.20 to - 0.01) on FEV 1 and FVC, respectively, in boys. BDLIMs also identified a sensitive window of exposure at 37-40 weeks gestation between higher prenatal PM 2.5 exposure and increased GSTP1 percent methylation. The association between higher GSTP1 percent methylation and decreased FEV1 was borderline significant in the sample as a whole (β = - 0.37, SE = 0.20, p = 0.06) and in boys in stratified analyses (β = - 0.56, SE = 0.29, p = 0.05). Prenatal PM 2.5 exposure in late pregnancy was associated with impaired early childhood lung function and hypermethylation of GSTPI in DNA isolated from nasal epithelial cells. There was a trend towards higher GSTP1 percent methylation being associated with reduced FEV1. All findings were most evident among boys.

  15. Effect of heliox- and air-driven nebulized bronchodilator therapy on lung function in patients with asthma.

    PubMed

    El-Khatib, Mohamad F; Jamaleddine, Ghassan; Kanj, Nadim; Zeineddine, Salah; Chami, Hassan; Bou-Akl, Imad; Husari, Ahmad; Alawieh, Marwan; Bou-Khalil, Pierre

    2014-06-01

    This study compares the effect of heliox-driven to that of air-driven bronchodilator therapy on the pulmonary function test (PFT) in patients with different levels of asthma severity. One-hundred thirty-two participants were included in the study. Participants underwent spirometry twice with bronchodilator testing on two consecutive days. Air-driven nebulization was used one day and heliox-driven nebulization the other day in random order crossover design. After a baseline PFT, each participant received 2.5 mg of albuterol sulfate nebulized with the randomized driving gas. Post bronchodilator PFT was repeated after 30 min. The next day, the exact same protocol was repeated, except that the other driving gas was used to nebulize the drug. Participants were subgrouped and analyzed according to their baseline FEV(1) on day 1: Group I, FEV(1) ≥80 %; Group II, 80 % > FEV(1) > 50 %; Group III, FEV(1) ≤50 %. The proportion of participants with greater than 12 % and 200-mL increases from their baseline FEV(1) and the changes from baseline in PFT variables were compared between heliox-driven versus air-driven bronchodilation therapy. The proportion of participants with >12 % and 200-mL increases from their baseline FEV(1) with air- or heliox-driven bronchodilation was not different with respect to the proportion of participants with baseline FEV(1) ≥80 % (20 vs. 18 %, respectively) and 80 % > FEV(1) > 50 % (36 vs. 43 %, respectively), but it was significantly greater with heliox-driven bronchodilation in participants with FEV(1) ≤50 % (43 vs. 73 %, respectively; p = 0.01). Changes from baseline FVC, FEV(1), FEV(1)/FVC, FEF(25-75) %, FEF(max), FEF(25) %, FEF(50) %, and FEF(75) % were significantly larger with heliox-driven versus air-driven bronchodilation in participants with baseline FEV(1) ≤50 %. Improvements in PFT variables are more frequent and profound with heliox-driven compared to air-driven bronchodilator therapy only in asthmatic patients with baseline FEV(1) ≤50 %.

  16. Children and young adults with CF in the USA have better lung function compared with the UK.

    PubMed

    Goss, Christopher H; MacNeill, Stephanie J; Quinton, Hebe B; Marshall, Bruce C; Elbert, Alexander; Knapp, Emily A; Petren, Kristofer; Gunn, Elaine; Osmond, Joanne; Bilton, Diana

    2015-03-01

    People with cystic fibrosis (CF) are managed differently in the USA and UK providing an opportunity to learn from differences in practice patterns. To compare cross-sectional demographics, practice patterns and clinical outcomes between US and UK CF patients. This was a cross-sectional study using 2010 data from patients in the US Cystic Fibrosis Foundation and the UK Cystic Fibrosis patient registries. The a priori outcome measures of interest were lung function and nutritional status. Descriptive statistics and two sample comparisons were performed. Stratification and multivariable linear regression were used to adjust for confounding. The study cohort included 13 777 children and 11 058 adults from the USA and 3968 children and 3965 adults from the UK. In children, mean body mass index centiles were similar. Lung function (FEV1 and FVC% predicted) was significantly higher in US patients ages 6-25 years of age. In a regression model adjusted for only age, FEV1% predicted was on average 3.31% of predicted (95% CI 2.65 to 3.96) higher in the USA compared with the UK. When adjusted for age, age at diagnosis, gender, pancreatic insufficiency and genotype, FEV1% predicted was on average 3.03% of predicted (95% CI 2.37 to 3.69) higher in the USA compared with the UK These differences persisted despite adjustment for possible confounders. Hypertonic saline and dornase alfa were much more commonly prescribed in US children. Children and young adults with CF have better lung function in the USA compared with the UK despite similar nutritional status. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Early respiratory infection is associated with reduced spirometry in children with cystic fibrosis.

    PubMed

    Ramsey, Kathryn A; Ranganathan, Sarath; Park, Judy; Skoric, Billy; Adams, Anne-Marie; Simpson, Shannon J; Robins-Browne, Roy M; Franklin, Peter J; de Klerk, Nick H; Sly, Peter D; Stick, Steve M; Hall, Graham L

    2014-11-15

    Pulmonary inflammation, infection, and structural lung disease occur early in life in children with cystic fibrosis. We hypothesized that the presence of these markers of cystic fibrosis lung disease in the first 2 years of life would be associated with reduced lung function in childhood. Lung function (forced expiratory volume in the first three-quarters of a second [FEV0.75], FVC) was assessed in individuals with cystic fibrosis diagnosed after newborn screening and healthy subjects during infancy (0-2 yr) and again at early school age (4-8 yr). Individuals with cystic fibrosis underwent annual bronchoalveolar lavage fluid examination, and chest computed tomography. We examined which clinical outcomes (pulmonary inflammation, infection, structural lung disease, respiratory hospitalizations, antibiotic prophylaxis) measured in the first 2 years of life were associated with reduced lung function in infants and young children with cystic fibrosis, using a mixed effects model. Children with cystic fibrosis (n = 56) had 8.3% (95% confidence interval [CI], -15.9 to -6.6; P = 0.04) lower FEV0.75 compared with healthy subjects (n = 18). Detection of proinflammatory bacterial pathogens (Pseudomonas aeruginosa, Staphylococcus aureus, Haemophilus influenzae, Aspergillus species, Streptococcus pneumoniae) in bronchoalveolar lavage fluid was associated with clinically significant reductions in FEV0.75 (ranging between 11.3 and 15.6%). The onset of lung disease in infancy, specifically the occurrence of lower respiratory tract infection, is associated with low lung function in young children with cystic fibrosis. Deficits in lung function measured in infancy persist into childhood, emphasizing the need for targeted therapeutic interventions in infancy to maximize functional outcomes later in life.

  18. Heritability of Lung Disease Severity in Cystic Fibrosis

    PubMed Central

    Vanscoy, Lori L.; Blackman, Scott M.; Collaco, Joseph M.; Bowers, Amanda; Lai, Teresa; Naughton, Kathleen; Algire, Marilyn; McWilliams, Rita; Beck, Suzanne; Hoover-Fong, Julie; Hamosh, Ada; Cutler, Dave; Cutting, Garry R.

    2007-01-01

    Rationale: Obstructive lung disease, the major cause of mortality in cystic fibrosis (CF), is poorly correlated with mutations in the disease-causing gene, indicating that other factors determine severity of lung disease. Objectives: To quantify the contribution of modifier genes to variation in CF lung disease severity. Methods: Pulmonary function data from patients with CF living with their affected twin or sibling were converted into reference values based on both healthy and CF populations. The best measure of FEV1 within the last year was used for cross-sectional analysis. FEV1 measures collected over at least 4 years were used for longitudinal analysis. Genetic contribution to disease variation (i.e., heritability) was estimated in two ways: by comparing similarity of lung function in monozygous (MZ) twins (∼ 100% gene sharing) with that of dizygous (DZ) twins/siblings (∼ 50% gene sharing), and by comparing similarity of lung function measures for related siblings to similarity for all study subjects. Measurements and Main Results: Forty-seven MZ twin pairs, 10 DZ twin pairs, and 231 sibling pairs (of a total of 526 patients) with CF were studied. Correlations for all measures of lung function for MZ twins (0.82–0.91, p < 0.0001) were higher than for DZ twins and siblings (0.50–0.64, p < 0.001). Heritability estimates from both methods were consistent for each measure of lung function and ranged from 0.54 to 1.0. Heritability estimates generally increased after adjustment for differences in nutritional status (measured as body mass index z-score). Conclusions: Our heritability estimates indicate substantial genetic control of variation in CF lung disease severity, independent of CFTR genotype. PMID:17332481

  19. Effects of side lying on lung function in older individuals.

    PubMed

    Manning, F; Dean, E; Ross, J; Abboud, R T

    1999-05-01

    Body positioning exerts a strong effect on pulmonary function, but its effect on other components of the oxygen transport pathway are less well understood, especially the effects of side-lying positions. This study investigated the interrelationships between side-lying positions and indexes of lung function such as spirometry, alveolar diffusing capacity, and inhomogeneity of ventilation in older individuals. Nineteen nonsmoking subjects (mean age=62.8 years, SD=6.8, range=50-74) with no history of cardiac or pulmonary disease were tested over 2 sessions. The test positions were sitting and left side lying in one session and sitting and right side lying in the other session. In each of the positions, forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), single-breath pulmonary diffusing capacity (DLCO/VA), and the slope of phase III (DN2%/L) of the single-breath nitrogen washout test to determine inhomogeneity of ventilation were measured. Compared with measurements obtained in the sitting position, FVC and FEV1 were decreased equally in the side-lying positions, but no change was observed in DLCO/VA or DN2%/L. Side-lying positions resulted in decreases in FVC and FEV1, which is consistent with the well-documented effects of the supine position. These findings further support the need for prescriptive rather than routine body positioning of patients with risks of cardiopulmonary compromise and the need to use upright positions in which lung volumes and capacities are maximized.

  20. Restrictive allograft syndrome (RAS): a novel form of chronic lung allograft dysfunction.

    PubMed

    Sato, Masaaki; Waddell, Thomas K; Wagnetz, Ute; Roberts, Heidi C; Hwang, David M; Haroon, Ayesha; Wagnetz, Dirk; Chaparro, Cecilia; Singer, Lianne G; Hutcheon, Michael A; Keshavjee, Shaf

    2011-07-01

    Bronchiolitis obliterans syndrome (BOS) with small-airway pathology and obstructive pulmonary physiology may not be the only form of chronic lung allograft dysfunction (CLAD) after lung transplantation. Characteristics of a form of CLAD consisting of restrictive functional changes involving peripheral lung pathology were investigated. Patients who received bilateral lung transplantation from 1996 to 2009 were retrospectively analyzed. Baseline pulmonary function was taken as the time of peak forced expiratory volume in 1 second (FEV(1)). CLAD was defined as irreversible decline in FEV(1) < 80% baseline. The most accurate threshold to predict irreversible decline in total lung capacity and thus restrictive functional change was at 90% baseline. Restrictive allograft syndrome (RAS) was defined as CLAD meeting this threshold. BOS was defined as CLAD without RAS. To estimate the effect on survival, Cox proportional hazards models and Kaplan-Meier analyses were used. Among 468 patients, CLAD developed in 156; of those, 47 (30%) showed the RAS phenotype. Compared with the 109 BOS patients, RAS patients showed significant computed tomography findings of interstitial lung disease (p < 0.0001). Prevalence of RAS was approximately 25% to 35% of all CLAD over time. Patient survival of RAS was significantly worse than BOS after CLAD onset (median survival, 541 vs 1,421 days; p = 0.0003). The RAS phenotype was the most significant risk factor of death among other variables after CLAD onset (hazard ratio, 1.60; confidential interval, 1.23-2.07). RAS is a novel form of CLAD that exhibits characteristics of peripheral lung fibrosis and significantly affects survival of lung transplant patients. Copyright © 2011 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  1. Violence exposure, a chronic psychosocial stressor, and childhood lung function

    PubMed Central

    Suglia, Shakira Franco; Ryan, Louise; Laden, Francine; Dockery, Douglas; Wright, Rosalind J

    2011-01-01

    Background Chronic psychosocial stressors, including violence, have been linked to neuropsychological and behavioral development in children as well as physiologic alterations that may lead to broader health effects. Methods We examined the relationship between violence and childhood lung function in a prospective birth cohort of 313 urban children 6 and 7 years of age. Mothers reported on their child’s lifetime exposure to community violence (ETV) and interparental conflict in the home [Conflict Tactics Scale (CTS)] within one year of the lung function assessment. Results In linear regression analyses, adjusting for maternal education, child’s age, race, birthweight, tobacco smoke exposure, and medical history, girls in the highest CTS verbal aggression tertile had a 5.5% (95% CI: −9.6, −1.5) decrease in percent predicted FEV1 and a 5.4% (95% CI: −9.7, −1.1) decrease in FVC compared to girls in the lowest tertile. The CTS verbal aggression subscale was associated with lung function among boys in the same direction, albeit this was not statistically significant. Boys in the highest ETV tertile had a 3.4% (95% CI: −8.0, 1.1) lower FEV1 and 5.3% lower (95% CI: −10.2, −0.4) FVC compared to boys in the lowest tertile. The ETV score was not a significant predictor of girl’s lung function. Conclusions Interparental conflict, specifically verbal aggression, and exposure to community violence were associated with decreased childhood lung function independent of socioeconomic status, tobacco smoke exposure, birthweight and respiratory illness history. Gender differences were noted based on the type of violence exposure which may warrant further exploration. PMID:18158365

  2. The Short-Term Effect of Breathing Tasks Via an Incentive Spirometer on Lung Function Compared With Autogenic Drainage in Subjects With Cystic Fibrosis.

    PubMed

    Sokol, Gil; Vilozni, Daphna; Hakimi, Ran; Lavie, Moran; Sarouk, Ifat; Bat-El Bar; Dagan, Adi; Ofek, Miryam; Efrati, Ori

    2015-12-01

    Forced expiration may assist secretion movement by manipulating airway dynamics in patients with cystic fibrosis (CF). Expiratory resistive breathing via a handheld incentive spirometer has the potential to control the expiratory flow via chosen resistances (1-8 mm) and thereby mobilize secretions and improve lung function. Our objective was to explore the short-term effect of using a resistive-breathing incentive spirometer on lung function in subjects with CF compared with the autogenic drainage technique. This was a retrospective study. Subjects with CF performed 30-45 min of either the resistive-breathing incentive spirometer (n = 40) or autogenic drainage (n = 32) technique on separate days. The spirometer encourages the patient to exhale as long as possible while maintaining a low lung volume. The autogenic drainage technique includes repetitive inspiratory and expiratory maneuvers at various tidal breathing magnitudes while exhalation is performed in a sighing manner. Spirometry was performed before and 20-30 min after the therapy. Use of a resistive-breathing incentive spirometer improved FVC and FEV1 by 5-42% in 26 subjects. The forced expiratory flow during the middle half of the FVC maneuver (FEF25-75%) improved by >20% in 9 (22%) subjects. FVC improved the most in subjects with an FEV1 of 40-60% of predicted. Improvements negatively correlated with baseline percent-of-predicted FVC values provided improvements were above 10% (r(2) = 0.28). Values improved in a single subjects using the autogenic drainage technique. These 2 techniques may allow lower thoracic pressures and assist in the prevention of central airway collapse. The resistive-breathing incentive spirometer is a self-administered simple method that may aid airway clearance and has the potential to improve lung function as measured by FVC, FEV1, and FEF25-75% in patients with CF. Copyright © 2015 by Daedalus Enterprises.

  3. [Respiratory function in heroin addicts with or without HIV infection. Study of 107 cases with a 6-month follow-up of 36 subjects].

    PubMed

    Escamilla, R; Pecoul, J; Hermant, C; Besombes, J P; Krempf, M

    1992-01-01

    Both intravenous drug addiction (IVDA) and HIV infection can involve respiratory system. So, we have studied pulmonary function in 107 heroin abusers during deprivation to clarify the extent of these two factors respectively. Two groups were separated: 50 subjects without HIV infection (HIV-) and 57 seropositive subjects (HIV+) in early stage of the disease (mean CD4 lymphocytes: 457 +/- 61/mm3). 36 subjects have been investigated 6 months later to evaluate the reversibility of possible observed abnormalities. Altered pulmonary function was encountered similarly in HIV+ and HIV-. DLco was abnormal in 40% of cases both in HIV+ (mean DLco: 63.4 +/- 1.1% of predicted values) and HIV- (mean DLco: 65.4 +/- 1.5% pred); obstructive lung disease was present in 18% of HIV- (FEV1/VC: 63.8 +/- 2.5) and 9% of HIV+ (FEV1/VC: 61 +/- 3.6); restrictive lung disease was found more frequently (16% vs 10%) in HIV+ (FEV1/VC: 81.2 +/- 2.1, TLC: 72.4 +/- 3.6% pred) than in HIV- (FEV1/VC: 84.2 +/- 1.6, TLC: 71.2 +/- 0.9% pred). These abnormalities were not associated with significant arterial blood gas modifications. As a whole, DLco tend to improve in the two groups and this significantly for HIV+ (p less than 0.03). But for individuals initial DLco alteration was persistent in 68% of cases suggesting slow improvement. In conclusion, in this study HIV+ and HIV- IVDA were not different concerning pulmonary function. In this risk group, DLco itself had a poor specificity and only it follow-up may be of interest for pulmonary opportunistic infection screening.

  4. African ancestry, lung function and the effect of genetics

    PubMed Central

    Wehrmeister, Fernando C.; Hartwig, Fernando P.; Perez-Padilla, Rogelio; Gigante, Denise P.; Barros, Fernando C.; Oliveira, Isabel O.; Ferreira, Gustavo D.; Horta, Bernardo L.

    2015-01-01

    African-Americans have smaller lung function compared with European-Americans. The aim of this study was to disentangle the contribution of genetics from other variables on lung function. A cohort was followed from birth to 30 years of age in Brazil. Several variables were collected: genomic analysis based on DNA; forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) obtained by spirometry; height measured by anthropometrists; and thorax circumference evaluated by photonic scanner. Crude and adjusted linear regression models were calculated according to African ancestry. The sample comprised 2869 participants out of 3701 members of the cohort. Males with higher African ancestry by DNA analysis had a smaller FEV1 (−0.13 L, 95% CI −0.23– −0.03 L) and FVC (−0.21 L, 95% CI −0.32– −0.09 L) compared with those with less African ancestry, having accounted for height, sitting to standing height ratio and other confounders. Similar effects were seen in females. After adjustment, ancestry remained significantly associated with lung function, but the large effect of adjustment for confounding among males (but not females) does not allow us to exclude the possibility that residual confounding may still account for these findings. PMID:25700383

  5. Contribution of CT quantified emphysema, air trapping and airway wall thickness on pulmonary function in male smokers with and without COPD.

    PubMed

    Mohamed Hoesein, Firdaus A A; de Jong, Pim A; Lammers, Jan-Willem J; Mali, Willem P Th M; Mets, Onno M; Schmidt, Michael; de Koning, Harry J; Aalst, Carlijn van der; Oudkerk, Matthijs; Vliegenthart, Rozemarijn; Ginneken, Bram van; van Rikxoort, Eva M; Zanen, Pieter

    2014-09-01

    Emphysema, airway wall thickening and air trapping are associated with chronic obstructive pulmonary disease (COPD). All three can be quantified by computed tomography (CT) of the chest. The goal of the current study is to determine the relative contribution of CT derived parameters on spirometry, lung volume and lung diffusion testing. Emphysema, airway wall thickening and air trapping were quantified automatically on CT in 1,138 male smokers with and without COPD. Emphysema was quantified by the percentage of voxels below -950 Hounsfield Units (HU), airway wall thickness by the square root of wall area for a theoretical airway with 10 mm lumen perimeter (Pi10) and air trapping by the ratio of mean lung density at expiration and inspiration (E/I-ratio). Spirometry, residual volume to total lung capacity (RV/TLC) and diffusion capacity (Kco) were obtained. Standardized regression coefficients (β) were used to analyze the relative contribution of CT changes to pulmonary function measures. The independent contribution of the three CT measures differed per lung function parameter. For the FEV1 airway wall thickness was the most contributing structural lung change (β = -0.46), while for the FEV1/FVC this was emphysema (β = -0.55). For the residual volume (RV) air trapping was most contributing (β = -0.35). Lung diffusion capacity was most influenced by emphysema (β = -0.42). In a cohort of smokers with and without COPD the effect of different CT changes varies per lung function measure and therefore emphysema, airway wall thickness and air trapping need to be taken in account.

  6. Respiratory symptoms and pulmonary function impairment among detergent plant workers in Jos, Northern Nigeria.

    PubMed

    Babashani, M; Iliyasu, Z; Ukoli, C O

    2008-01-01

    The industrial process of detergent production could be deleterious to lung function. This study describes respiratory symptoms and ventilatory function impairment among detergent workers in Jos, Northern Nigeria. Two hundred detergent plant workers and controls were studied for the presence of respiratory symptoms and ventilatory function impairment using the MRC questionnaire and Spirometry. A significantly higher proportion of exposed detergent workers 178 (87.0%) reported respiratory symptoms compared to 52 (26.0%) controls [OR=23; 95% CI=12.9-41.3] (P<0.001). Commonest symptoms include rhinitis (57.5% versus 11.0%) and cough (48.5% versus 15%). Symptoms were most prevalent in the packaging section. FEV1, FVC and PEFR were significantly reduced among exposed detergent workers. Similarly, the predicted values of PEFR, FVC and FEV1, were significantly reduced among smokers (P<0. 001). Respiratory symptoms are highly prevalent among detergent workers. This was associated with impaired pulmonary function. Protective equipment and periodic lung function tests could reduce these effects.

  7. Effects of occupational exposures and smoking on lung function in tile factory workers.

    PubMed

    Jaakkola, Maritta S; Sripaiboonkij, Penpatra; Jaakkola, Jouni J K

    2011-02-01

    The aims of this study were to investigate the relations of occupational exposures in tile industry to lung function and to evaluate potential interaction between smoking and tile dust exposure containing silica. A cross-sectional study of 232 workers (response rate 100%) in a tile factory and 76 office workers (response rate 73%) from four factories in Thailand was conducted in 2006-2007. Participants answered a questionnaire and performed spirometry. Factory workers had lower spirometric functions than office workers, especially those with high dust exposure. There was a dose-response relation between duration of dust exposure and FEV1 and FVC, the adjusted effect of ≥ 21 years of exposure on FEV1 being -240 ml (-100 to -380) and on FVC -300 ml (-140 to -460). The adverse effect of dust on lung function was larger in current smokers suggesting synergism between smoking and tile dust exposure. This study provides evidence that long-term exposure to dust in tile industry is related to lung function reduction. There was a suggestion of synergistic effect between dust exposure and smoking. Tile factories should consider measures to reduce dust exposure and arrange spirometry surveillance for workers with such exposure. Smoking cessation should be promoted to prevent harmful effects of occupational tile dust exposure.

  8. Effect of indoor air pollution on the respiratory system of women using different fuels for cooking in an urban slum of Pondicherry.

    PubMed

    Dutt, D; Srinivasa, D K; Rotti, S B; Sahai, A; Konar, D

    1996-01-01

    Some of the highest exposures to air pollutants in developing countries occur inside homes where biofuels are used for daily cooking. Inhalation of these pollutants may cause deleterious effects on health. We studied the effects of exposure to indoor air pollution from the use of cooking fuels on lung functions and respiratory symptoms in women aged 15-60 years. The study was conducted in Kuruchikuppam, an urban slum in Pondicherry. The study participants were 105 women using biofuels, 105 using kerosene and 105 using liquid petroleum gas (LPG), selected from among 1117 women aged 15-60 years, by a stratified random sampling technique. These women were interviewed at home to collect information about exposure to fuel smoke and presence of respiratory symptoms. Lung functions were assessed by measuring forced vital capacity (FVC), forced expiratory volume in the first second (FEV1) and peak expiratory flow rate (PEFR). Occurrence of respiratory symptoms over six months was noted by making monthly follow up visits. Women using biofuels experienced more respiratory symptoms (23%) than those using kerosene (13%;p > 0.05) or LPG (8%; p < 0.05). Lung functions-FVC, FEV1, FEV1% and PEFR-were significantly lower in biofuel users compared with both kerosene (p < 0.01) and LPG users (p < 0.001). Lung functions in kerosene users also were significantly poorer when compared with LPG users (p < 0.01). Predicted pulmonary functions using multiple regression equations, derived from the data set of the present study, indicated that women using biofuels were more liable to have reduced pulmonary functions than women using kerosene or LPG. Women exposed to biofuel smoke suffer more from respiratory illnesses and have decreased pulmonary functions compared with women exposed to kerosene or LPG smoke. To reduce pollutant exposures we recommend the use of smokeless chullas or cleaner fuels such as charcoal, biogas and kerosene.

  9. Factors Affecting Lung Function: A Review of the Literature.

    PubMed

    Talaminos Barroso, Alejandro; Márquez Martín, Eduardo; Roa Romero, Laura María; Ortega Ruiz, Francisco

    2018-06-01

    Lung function reference values are traditionally based on anthropometric factors, such as weight, height, sex, and age. FVC and FEV 1 decline with age, while volumes and capacities, such as RV and FRC, increase. TLC, VC, RV, FVC and FEV 1 are affected by height, since they are proportional to body size. This means that a tall individual will experience greater decrease in lung volumes as they get older. Some variables, such as FRC and ERV, decline exponentially with an increase in weight, to the extent that tidal volume in morbidly obese patients can be close to that of RV. Men have longer airways than women, causing greater specific resistance in the respiratory tract. The increased work of breathing to increase ventilation among women means that their consumption of oxygen is higher than men under similar conditions of physical intensity. Lung volumes are higher when the subject is standing than in other positions. DLCO is significantly higher in supine positions than in sitting or standing positions, but the difference between sitting and standing positions is not significant. Anthropometric characteristics are insufficient to explain differences in lung function between different ethnic groups, underlining the importance of considering other factors in addition to the conventional anthropometric measurements. Copyright © 2018 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Cumulative exposure to dust and gases as determinants of lung function decline in tunnel construction workers

    PubMed Central

    Bakke, B; Ulvestad, B; Stewart, P; Eduard, W

    2004-01-01

    Aims: To study the relation between lung function decrease and cumulative exposure to dust and gases in tunnel construction workers. Methods: A total of 651 male construction workers (drill and blast workers, tunnel concrete workers, shotcreting operators, and tunnel boring machine workers) were followed up by spirometric measurements in 1989–2002 for an average of six years. Outdoor concrete workers, foremen, and engineers served as a low exposed referent population. Results: The between worker component of variability was considerably reduced within the job groups compared to the whole population, suggesting that the workers within job groups had similar exposure levels. The annual decrease in FEV1 in low-exposed non-smoking workers was 21 ml and 24 ml in low-exposed ever smokers. The annual decrease in FEV1 in tunnel construction workers was 20–31 ml higher than the low exposed workers depending on job group for both non-smokers and ever smokers. After adjustment for age and observation time, cumulative exposure to nitrogen dioxide showed the strongest association with a decrease in FEV1 in both non-smokers, and ever smokers. Conclusion: Cumulative exposure to nitrogen dioxide appeared to be a major risk factor for lung function decreases in these tunnel construction workers, although other agents may have contributed to the observed effect. Contact with blasting fumes should be avoided, diesel exhaust emissions should be reduced, and respiratory devices should be used to protect workers against dust and nitrogen dioxide exposure. PMID:14985522

  11. Study of computerized spirometric parameters of traffic police personnel of Saurashtra region, Gujarat, India.

    PubMed

    Makwana, Amit H; Solanki, Jayesh D; Gokhale, Pradnya A; Mehta, Hemant B; Shah, Chinmay J; Gadhavi, Bhakti P

    2015-01-01

    Air pollution due to road traffic is a serious health hazard and air quality crisis in cities is mainly due to vehicular emission. Thus the persons who are continuously exposed are at an increased risk. The study was carried out to evaluate the extent of impairment in lung function in traffic police personnel compared to matched unexposed control group. A cross-sectional study was conducted to measure the spirometric parameters of 100 traffic police personnel, aged 20-55 years, working in Saurashtra region, as compared to matched control group, consisting of 100 unexposed males. Measurement of lung volumes and capacities was done with SPIROEXCEL. The statistical analysis was carried out with Graph pad instat 3. Traffic police personnel had significantly declined forced vital capacity (FVC), forced expiratory volume in one second (FEV 1), slow vital capacity (SVC) and maximum voluntary ventilation (MVV) when compared with predictive normal values, which is probably due to exposure to vehicular exhaust. Comparison of test values between groups showed significantly reduced FVC, MVV and increased FEV1/FVC ratio and insignificantly declined FEV1 and SVC in cases as compared to controls. Traffic personnel with longer duration of exposure showed significantly reduced lung functions than those with shorter duration. Smokers showed lower test values as compared to non-smokers with significance only in unexposed group. The effect of pollution by vehicular exhausts may be responsible for these pulmonary function impairments and traffic police personnel should be offered personal protective or preventive measures.

  12. Effect of ivacaftor in patients with advanced cystic fibrosis and a G551D-CFTR mutation: Safety and efficacy in an expanded access program in the United States.

    PubMed

    Taylor-Cousar, Jennifer; Niknian, Minoo; Gilmartin, Geoffrey; Pilewski, Joseph M

    2016-01-01

    Ivacaftor is the first therapeutic agent approved for the treatment of cystic fibrosis (CF) that targets the underlying molecular defect. Patients with severe lung disease were excluded from the randomized Phase 3 trials. This open-label study was designed to provide ivacaftor to patients in critical medical need prior to commercial product availability. CF patients aged ≥6 years with a G551D-CFTR mutation and FEV1 ≤ 40% predicted or listed for lung transplant received ivacaftor 150 mg every 12 h. The primary endpoint was safety as determined by adverse events. Secondary endpoints included assessment of lung function and weight. The rate of serious adverse events was consistent with disease severity. At 24 weeks of treatment with ivacaftor, there was a mean absolute increase in percent predicted FEV1 of 5.5 percentage points and a 3.3 kg mean absolute increase in weight from baseline. In patients with severe lung disease, ivacaftor was well tolerated and was associated with improved lung function and weight gain. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  13. Lung function and long-term safety of tiotropium/olodaterol in East Asian patients with chronic obstructive pulmonary disease.

    PubMed

    Bai, Chunxue; Ichinose, Masakazu; Lee, Sang Haak; Lee, Kwan Ho; Jöns, Olaf; Bothner, Ulrich; Zhao, Yihua; Buhl, Roland

    2017-01-01

    While the efficacy and safety of combined tiotropium and olodaterol in patients with COPD was established in a large clinical trial program, it is important to assess whether clinical data can be applied to geographic patient groups, particularly for East Asian patients who may have a different phenotypic profile to the global trial population. This study aimed to compare the lung function and safety profiles of tiotropium/olodaterol and monocomponents in East Asian and global populations from the TONADO ® trials. In the replicate, double-blind, parallel-group, active-controlled, randomized, 52-week, Phase III TONADO studies, patients received tiotropium/olodaterol, tiotropium, or olodaterol. We assessed the forced expiratory volume in 1 second (FEV 1 ) area under the curve from 0 to 3 hours (AUC 0-3 ) response and trough FEV 1 response at 24 weeks for the approved doses, tiotropium/olodaterol 5/5 μg, tiotropium 5 μg, and olodaterol 5 μg. Treatment-emergent adverse events were recorded throughout treatment and ≤21 days after study medication. In the East Asian population, 1,152 patients were randomized (5,163 overall). After 24 weeks, FEV 1 AUC 0-3 and trough FEV 1 responses were greater ( P <0.0001) with tiotropium/olodaterol 5/5 μg in both populations versus tiotropium or olodaterol. The East Asian population showed slightly greater trough FEV 1 treatment differences between tiotropium/olodaterol 5/5 μg and tiotropium compared to the overall population. Generally, no increase in adverse events was seen with tiotropium/olodaterol 5/5 μg compared to tiotropium and olodaterol in either population. The efficacy and safety profile of tiotropium/olodaterol 5/5 μg has been demonstrated for both East Asian and global populations.

  14. Respiratory symptoms and ventilatory functions among quarry workers in Edo state, Nigeria

    PubMed Central

    Isara, Alphonsus Rukevwe; Adam, Vincent Yakubu; Aigbokhaode, Adesuwa Queen; Alenoghena, Innocent Osi

    2016-01-01

    Introduction Workers in the quarry industries are exposed to hazards resulting from the inhalation of air borne particulates. The study determined the prevalence of respiratory symptoms and assessed ventilatory functions among quarry workers in Edo state, Nigeria. Methods Quarry workers (site workers and office workers) were interviewed using structured questionnaire. FEV1, FVC, FEV1/FVC and PEFR were measured using a KoKo Legend spirometer. Results A total of 113 quarry workers (76 exposure and 37 controls) were studied. The exposure group had significantly higher occurrence of chest tightness (35.5%) compared with 16.2% of the controls (p < 0.05). The occurrence of cough (23.7% versus 13.5%), sputum (21.1% versus 16.2%), and dyspnoea (7.9% versus 5.4%), were higher in exposure groups while wheeze (10.8% versus 10.5%) and nasal congestion (27.0% and 25.0%) were higher in the control groups. The mean (SD) FEV1, and FVC were significantly lower among the exposure compared with the control group; 2.77L (0.73) versus 3.14L (0.78), p < 0.05, and 3.48L (0.84) versus 3.89L (0.92), p < 0.05. In both groups, smokers had significantly lower mean (SD) FEV1, FVC and PEFR compared with non-smokers; 2.91L (0.77) versus 3.39L (0.69), p = 0.01, 3.61L (0.91) versus 4.26L (0.74), p < 0.05 and 6.56L (2.43) versus 7.98L (1.67), p < 0.05. Conclusion Chronic exposure to quarry dust is associated with respiratory symptoms and reduced lung function indices among quarry workers. The enforcement of the use of PPEs and periodic evaluation the lung function status of quarry workers is advocated. PMID:27347301

  15. Respiratory symptoms and ventilatory functions among quarry workers in Edo state, Nigeria.

    PubMed

    Isara, Alphonsus Rukevwe; Adam, Vincent Yakubu; Aigbokhaode, Adesuwa Queen; Alenoghena, Innocent Osi

    2016-01-01

    Workers in the quarry industries are exposed to hazards resulting from the inhalation of air borne particulates. The study determined the prevalence of respiratory symptoms and assessed ventilatory functions among quarry workers in Edo state, Nigeria. Quarry workers (site workers and office workers) were interviewed using structured questionnaire. FEV1, FVC, FEV1/FVC and PEFR were measured using a KoKo Legend spirometer. A total of 113 quarry workers (76 exposure and 37 controls) were studied. The exposure group had significantly higher occurrence of chest tightness (35.5%) compared with 16.2% of the controls (p < 0.05). The occurrence of cough (23.7% versus 13.5%), sputum (21.1% versus 16.2%), and dyspnoea (7.9% versus 5.4%), were higher in exposure groups while wheeze (10.8% versus 10.5%) and nasal congestion (27.0% and 25.0%) were higher in the control groups. The mean (SD) FEV1, and FVC were significantly lower among the exposure compared with the control group; 2.77L (0.73) versus 3.14L (0.78), p < 0.05, and 3.48L (0.84) versus 3.89L (0.92), p < 0.05. In both groups, smokers had significantly lower mean (SD) FEV1, FVC and PEFR compared with non-smokers; 2.91L (0.77) versus 3.39L (0.69), p = 0.01, 3.61L (0.91) versus 4.26L (0.74), p < 0.05 and 6.56L (2.43) versus 7.98L (1.67), p < 0.05. Chronic exposure to quarry dust is associated with respiratory symptoms and reduced lung function indices among quarry workers. The enforcement of the use of PPEs and periodic evaluation the lung function status of quarry workers is advocated.

  16. Pulmonary involvement in Fabry disease: effect of plasma globotriaosylsphingosine and time to initiation of enzyme replacement therapy.

    PubMed

    Franzen, Daniel; Haile, Sarah R; Kasper, David C; Mechtler, Thomas P; Flammer, Andreas J; Krayenbühl, Pierre A; Nowak, Albina

    2018-01-01

    Anderson-Fabry disease (AFD) is an X-linked lysosomal storage disorder caused by mutations of GLA gene leading to reduced α-galactosidase activity and resulting in a progressive accumulation of globotriaosylceramide (Gb3) and its deacylated derivative, globotriaosyl-sphingosine (Lyso-Gb3). Plasma Lyso-Gb3 levels serve as a disease severity and treatment monitoring marker during enzyme replacement therapy (ERT). Adult patients with AFD who had yearly pulmonary function tests between 1999 and 2015 were eligible for this observational study. Primary outcome measures were the change in z-score of forced expiratory volume in the first second (FEV 1 ) and FEV 1 /FVC over time. Plasma Lyso-Gb3 levels and the age of ERT initiation were investigated for their association with lung function decline. Fifty-three patients (42% male, median (range) age at diagnosis of AFD 34 (6-61) years in men, 34 (13-67) in women) were included. The greatest decrease of FEV 1 /FVC z-scores was observed in Classic men (-0.048 per year, 95% CI -0.081 to -0.014), compared with the Later-Onset men (+0.013,95% CI -0.055 to 0.082), Classic women (-0.008, 95% CI -0.035 to +0.020) and Later-Onset women (-0.013, 95% CI -0.084 to +0.058). Cigarette smoking (P=0.022) and late ERT initiation (P=0.041) were independently associated with faster FEV 1 decline. FEV 1 /FVC z-score decrease was significantly reduced after initiation of ERT initiation (-0.045 compared with -0.015, P=0.014). Furthermore, there was a trend towards a relevant influence of Lyso-Gb3 (P=0.098) on airflow limitation with age. Early ERT initiation seems to preserve pulmonary function. Plasma Lyso-Gb3 is maybe a useful predictor for airflow limitation. Classic men need a closer monitoring of the lung function.

  17. Written Emotional Expression as an Intervention for Asthma

    ERIC Educational Resources Information Center

    Bray, Melissa A.; Theodore, Lea A.; Patwa, Shamim S.; Margiano, Suzanne G.; Alric, Jolie M.; Peck, Heather L.

    2003-01-01

    This investigation employed a multiple baseline design across five participants to examine written emotional expression as an intervention to improve lung function in high school-aged students, college students, and adults with asthma. The predicted forced expiratory volume in 1 second (FEV[subscript 1] measure of large airway functioning) and…

  18. Correlation between pulmonary function and brain volume in healthy elderly subjects.

    PubMed

    Taki, Yasuyuki; Kinomura, Shigeo; Ebihara, Satoru; Thyreau, Benjamin; Sato, Kazunori; Goto, Ryoi; Kakizaki, Masako; Tsuji, Ichiro; Kawashima, Ryuta; Fukuda, Hiroshi

    2013-06-01

    Cigarette smoking decreases brain regional gray matter volume and is related to chronic obstructive lung disease (COPD). COPD leads to decreased pulmonary function, which is represented by forced expiratory volume in one second percentage (FEV1.0 %); however, it is unclear if decreased pulmonary function is directly related to brain gray matter volume decline. Because there is a link between COPD and cognitive decline, revealing a direct relationship between pulmonary function and brain structure is important to better understand how pulmonary function affects brain structure and cognitive function. Therefore, the purpose of this study was to analyze whether there were significant correlations between FEV1.0 % and brain regional gray and white matter volumes using brain magnetic resonance (MR) image data from 109 community-dwelling healthy elderly individuals. Brain MR images were processed with voxel-based morphometry using a custom template by applying diffeomorphic anatomical registration using the exponentiated lie algebra procedure. We found a significant positive correlation between the regional white matter volume of the cerebellum and FEV1.0 % after adjusting for age, sex, and intracranial volume. Our results suggest that elderly individuals who have a lower FEV1.0 % have decreased regional white matter volume in the cerebellum. Therefore, preventing decreased pulmonary function is important for cerebellar white matter volume in the healthy elderly population.

  19. Total Airway Count on Computed Tomography and the Risk of Chronic Obstructive Pulmonary Disease Progression. Findings from a Population-based Study.

    PubMed

    Kirby, Miranda; Tanabe, Naoya; Tan, Wan C; Zhou, Guohai; Obeidat, Ma'en; Hague, Cameron J; Leipsic, Jonathon; Bourbeau, Jean; Sin, Don D; Hogg, James C; Coxson, Harvey O

    2018-01-01

    Studies of excised lungs show that significant airway attrition in the "quiet" zone occurs early in chronic obstructive pulmonary disease (COPD). To determine if the total number of airways quantified in vivo using computed tomography (CT) reflects early airway-related disease changes and is associated with lung function decline independent of emphysema in COPD. Participants in the multicenter, population-based, longitudinal CanCOLD (Canadian Chronic Obstructive Lung Disease) study underwent inspiratory/expiratory CT at visit 1; spirometry was performed at four visits over 6 years. Emphysema was quantified as the CT inspiratory low-attenuation areas below -950 Hounsfield units. CT total airway count (TAC) was measured as well as airway inner diameter and wall area using anatomically equivalent airways. Participants included never-smokers (n = 286), smokers with normal spirometry at risk for COPD (n = 298), Global Initiative for Chronic Obstructive Lung Disease (GOLD) I COPD (n = 361), and GOLD II COPD (n = 239). TAC was significantly reduced by 19% in both GOLD I and GOLD II compared with never-smokers (P < 0.0001) and by 17% in both GOLD I and GOLD II compared with at-risk participants (P < 0.0001) after adjusting for low-attenuation areas below -950 Hounsfield units. Further analysis revealed parent airways with missing daughter branches had reduced inner diameters (P < 0.0001) and thinner walls (P < 0.0001) compared with those without missing daughter branches. Among all CT measures, TAC had the greatest influence on FEV 1 (P < 0.0001), FEV 1 /FVC (P < 0.0001), and bronchodilator responsiveness (P < 0.0001). TAC was independently associated with lung function decline (FEV 1 , P = 0.02; FEV 1 /FVC, P = 0.01). TAC may reflect the airway-related disease changes that accumulate in the "quiet" zone in early/mild COPD, indicating that TAC acquired with commercially available software across various CT platforms may be a biomarker to predict accelerated COPD progression.

  20. Effect of vitamin D and inhaled corticosteroid treatment on lung function in children.

    PubMed

    Wu, Ann Chen; Tantisira, Kelan; Li, Lingling; Fuhlbrigge, Anne L; Weiss, Scott T; Litonjua, Augusto

    2012-09-15

    Low vitamin D levels are associated with asthma and decreased airway responsiveness. Treatment with inhaled corticosteroids improves airway responsiveness and asthma control. To assess the effect of vitamin D levels on prebronchodilator FEV(1), bronchodilator response, and responsiveness to methacholine (PC(20), provocative concentration of methacholine producing a 20% decline in FEV(1)) in patients with asthma treated with inhaled corticosteroids. We measured 25-hydroxyvitamin D levels in the serum of children with persistent asthma at the time of enrollment in the Childhood Asthma Management Program. We divided subjects into the vitamin D sufficiency (>30 ng/ml), insufficiency (20-30 ng/ml), and deficiency (<20 ng/ml) groups. Covariates included age, treatment, sex, body mass index, race, history of emergency department visits, hospitalizations, and season that vitamin D specimen was drawn. Our main outcome measures were change in prebronchodilator FEV(1), bronchodilator response, and PC(20) from enrollment to 8-12 months. Of the 1,024 subjects, 663 (65%) were vitamin D sufficient, 260 (25%) were insufficient, and 101 (10%) were deficient. Vitamin D-deficient subjects were more likely to be older, African American, and have a higher body mass index compared with the vitamin D-sufficient and insufficient subjects. In the inhaled corticosteroid treatment group, prebronchodilator FEV(1) increased from randomization to 12 months by 140 ml in the vitamin D-deficient group and prebronchodilator FEV(1) increased by 330 ml in the vitamin D insufficiency group and by 290 ml in the vitamin D sufficiency group (P = 0.0072), in adjusted models. In children with asthma treated with inhaled corticosteroids, vitamin D deficiency is associated with poorer lung function than in children with vitamin D insufficiency or sufficiency.

  1. Respiratory function in wind instrument players.

    PubMed

    Zuskin, Eugenija; Mustajbegovic, Jadranka; Schachter, E N; Kern, Josipa; Vitale, Ksenija; Pucarin-Cvetkovic, Jasna; Chiarelli, A; Milosevic, M; Jelinic, Jagoda Doko

    2009-01-01

    The playing of wind instruments has been associated with changes in respiratory function. To investigate the effect of playing wind instruments on lung function and respiratory symptoms. The present study included 99 wind instrument players and a group of 41 string instrument players as a control from 3 major orchestras in Zagreb, Croatia. Data on chronic respiratory symptoms were recorded in all studied subjects. Lung function was measured in wind instrument players by recording maximum expiratory flow-volume curves. Wind instrument players demonstrated significantly higher prevalences of sinusitis, nasal catarrh and hoarseness compared to control musicians. One wind instrument player developed asthma associated with his work. Odds ratios for wind instrument players were significant for chronic cough, chronic phlegm and chronic bronchitis by smoking habit (p<0.05 or p<0.01) but not for length of employment. Ventilatory capacity data indicate that wind instrument players had significantly greater FEV1 (smokers and nonsmokers) as well as FEF50 (nonsmokers) (p<0.05) compared to predicted values. Regression analysis of pulmonary function tests in wind instrument players demonstrate a significant link between FEV1 and FEF50 and length of employment. Those wind instrument players with longer employment had the greatest increases in lung function. Our data suggest that musicians playing wind instruments may be susceptible to chronic upper airway symptoms. Interestingly wind instrument playing may be associated with higher than expected lung function parameters.

  2. Pulmonary function deficits in newborn screened infants with cystic fibrosis managed with standard UK care are mild and transient.

    PubMed

    Davies, Gwyneth; Stocks, Janet; Thia, Lena P; Hoo, Ah-Fong; Bush, Andrew; Aurora, Paul; Brennan, Lucy; Lee, Simon; Lum, Sooky; Cottam, Philippa; Miles, Joanne; Chudleigh, Jane; Kirkby, Jane; Balfour-Lynn, Ian M; Carr, Siobhán B; Wallis, Colin; Wyatt, Hilary; Wade, Angie

    2017-11-01

    With the advent of novel designer molecules for cystic fibrosis (CF) treatment, there is huge need for early-life clinical trial outcomes, such as infant lung function (ILF). We investigated the degree and tracking of ILF abnormality during the first 2 years of life in CF newborn screened infants.Forced expiratory volume in 0.5 s (FEV 0.5 ), lung clearance index (LCI) and plethysmographic functional residual capacity were measured at ∼3 months, 1 year and 2 years in 62 infants with CF and 34 controls.By 2 years there was no significant difference in FEV 0.5 z-score between CF and controls, whereas mean LCI z-score was 0.81 (95% CI 0.45-1.17) higher in CF. However, there was no significant association between LCI z-score at 2 years with either 3-month or 1-year results. Despite minimal average group changes in any ILF outcome during the second year of life, marked within-subject changes occurred. No child had abnormal LCI or FEV 0.5 on all test occasions, precluding the ability to identify "high-risk" infants in early life.In conclusion, changes in lung function are mild and transient during the first 2 years of life in newborn screened infants with CF when managed according to a standardised UK treatment protocol. Their potential role in tracking disease to later childhood will be ascertained by ongoing follow-up. Copyright ©ERS 2017.

  3. Risk Evaluation of Construction Workers' Exposure to Silica Dust and the Possible Lung Function Impairments.

    PubMed

    Tavakol, Elahe; Azari, Mansour; Zendehdel, Rezvan; Salehpour, Sousan; Khodakrim, Soheila; Nikoo, Saeed; Saranjam, Behzad

    2017-06-01

    Aerosols generated during construction activities are an integral part of building operations. Considering the nature of materials used in construction activities, respirable dust contains crystalline silica and particulates not otherwise specified (PNOS). Due to lack of data regarding the occupational health status of Iranian construction workers, the objective of this study was to evaluate occupational exposure to silica and to examine their respiratory health status. In this cross sectional study, 85 construction workers and 40 controls (without active exposure to construction dust) were studied. The workers' exposure to PNOS and silica aerosols was monitored by the NIOSH method No.0600 and a new Fourier transform infrared spectroscopy (FTIR)-based method, respectively. All subjects were also monitored for lung function parameters, such as forced expiratory volume/forced vital capacity (FEV 1 /FVC), peak expiratory flow rate (PEFR), forced expiratory flow (FEF 25-75 ), FVC, and FEV 1 . The mean exposure of workers to respirable PNOS and silica was 9.8 (0.35) and 0.13 (0.019) mg/m 3 , respectively. The groups of construction workers showed significant differences in exposure to PNOS ( P < 0.001) and silica ( P = 0.007). The mean pulmonary function parameters, including FEV 1 % and FVC%, were significantly lower among construction workers, compared to the control group ( P < 0.001 and P = 0.009, respectively). The pulmonary status of 51.8% of construction workers showed moderate restriction, while 4.70% exhibited obstruction. Considering the construction workers' excessive exposure to PNOS and silica, besides depressed lung function parameters, they can be classified as a high-risk group for respiratory diseases.

  4. Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, F.; Graduate Program in Biomedical Engineering, University of Western Ontario, London, Ontario N6A 5B9; Svenningsen, S.

    Purpose: Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as intermediate endpoints of asthma severity and control. In particular, pulmonary {sup 1}H MRI can be used to provide quantitative lung structure-function measurements longitudinally and in response to treatment. However, to translate such biomarkers of asthma, robust methods are required to segment the lung from pulmonary {sup 1}H MRI. Therefore, their objective was to develop a pulmonary {sup 1}H MRI segmentationmore » algorithm to provide regional measurements with the precision and speed required to support clinical studies. Methods: The authors developed a method to segment the left and right lung from {sup 1}H MRI acquired in 20 asthmatics including five well-controlled and 15 severe poorly controlled participants who provided written informed consent to a study protocol approved by Health Canada. Same-day spirometry and plethysmography measurements of lung function and volume were acquired as well as {sup 1}H MRI using a whole-body radiofrequency coil and fast spoiled gradient-recalled echo sequence at a fixed lung volume (functional residual capacity + 1 l). We incorporated the left-to-right lung volume proportion prior based on the Potts model and derived a volume-proportion preserved Potts model, which was approximated through convex relaxation and further represented by a dual volume-proportion preserved max-flow model. The max-flow model led to a linear problem with convex and linear equality constraints that implicitly encoded the proportion prior. To implement the algorithm, {sup 1}H MRI was resampled into ∼3 × 3 × 3 mm{sup 3} isotropic voxel space. Two observers placed seeds on each lung and on the background of 20 pulmonary {sup 1}H MR images in a randomized dataset, on five occasions, five consecutive days in a row. Segmentation accuracy was evaluated using the Dice-similarity-coefficient (DSC) of the segmented thoracic cavity with comparison to five-rounds of manual segmentation by an expert observer. The authors also evaluated the root-mean-squared-error (RMSE) of the Euclidean distance between lung surfaces, the absolute, and percent volume error. Reproducibility was measured using the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) for two observers who repeated segmentation measurements five-times. Results: For five well-controlled asthmatics, forced expiratory volume in 1 s (FEV{sub 1})/forced vital capacity (FVC) was 83% ± 7% and FEV{sub 1} was 86 ± 9%{sub pred}. For 15 severe, poorly controlled asthmatics, FEV{sub 1}/FV C = 66% ± 17% and FEV{sub 1} = 72 ± 27%{sub pred}. The DSC for algorithm and manual segmentation was 91% ± 3%, 92% ± 2% and 91% ± 2% for the left, right, and whole lung, respectively. RMSE was 4.0 ± 1.0 mm for each of the left, right, and whole lung. The absolute (percent) volume errors were 0.1 l (∼6%) for each of right and left lung and ∼0.2 l (∼6%) for whole lung. Intra- and inter-CoV (ICC) were <0.5% (>0.91%) for DSC and <4.5% (>0.93%) for RMSE. While segmentation required 10 s including ∼6 s for user interaction, the smallest detectable difference was 0.24 l for algorithm measurements which was similar to manual measurements. Conclusions: This lung segmentation approach provided the necessary and sufficient precision and accuracy required for research and clinical studies.« less

  5. MMP12, Lung Function, and COPD in High-Risk Populations

    PubMed Central

    Hunninghake, Gary M.; Cho, Michael H.; Tesfaigzi, Yohannes; Soto-Quiros, Manuel E.; Avila, Lydiana; Lasky-Su, Jessica; Stidley, Chris; Melén, Erik; Söderhäll, Cilla; Hallberg, Jenny; Kull, Inger; Kere, Juha; Svartengren, Magnus; Pershagen, Göran; Wickman, Magnus; Lange, Christoph; Demeo, Dawn L.; Hersh, Craig P.; Klanderman, Barbara J.; Raby, Benjamin A.; Sparrow, David; Shapiro, Steven D.; Silverman, Edwin K.; Litonjua, Augusto A.; Weiss, Scott T.; Celedón, Juan C.

    2010-01-01

    BACKGROUND Genetic variants influencing lung function in children and adults may ultimately lead to the development of chronic obstructive pulmonary disease (COPD), particularly in high-risk groups. METHODS We tested for an association between single-nucleotide polymorphisms (SNPs) in the gene encoding matrix metalloproteinase 12 (MMP12) and a measure of lung function (prebronchodilator forced expiratory volume in 1 second [FEV1]) in more than 8300 subjects in seven cohorts that included children and adults. Within the Normative Aging Study (NAS), a cohort of initially healthy adult men, we tested for an association between SNPs that were associated with FEV1 and the time to the onset of COPD. We then examined the relationship between MMP12 SNPs and COPD in two cohorts of adults with COPD or at risk for COPD. RESULTS The minor allele (G) of a functional variant in the promoter region of MMP12 (rs2276109 [−82A→G]) was positively associated with FEV1 in a combined analysis of children with asthma and adult former and current smokers in all cohorts (P=2×10−6). This allele was also associated with a reduced risk of the onset of COPD in the NAS cohort (hazard ratio, 0.65; 95% confidence interval [CI], 0.46 to 0.92; P = 0.02) and with a reduced risk of COPD in a cohort of smokers (odds ratio, 0.63; 95% CI, 0.45 to 0.88; P = 0.005) and among participants in a family-based study of early-onset COPD (P = 0.006). CONCLUSIONS The minor allele of a SNP in MMP12 (rs2276109) is associated with a positive effect on lung function in children with asthma and in adults who smoke. This allele is also associated with a reduced risk of COPD in adult smokers. PMID:20018959

  6. Lifetime Exposure to Ambient Pollution and Lung Function in Children

    PubMed Central

    Rifas-Shiman, Sheryl L.; Litonjua, Augusto A.; Oken, Emily; Gillman, Matthew W.; Kloog, Itai; Luttmann-Gibson, Heike; Zanobetti, Antonella; Coull, Brent A.; Schwartz, Joel; Koutrakis, Petros; Mittleman, Murray A.; Gold, Diane R.

    2016-01-01

    Rationale: Few studies have examined associations between exposure to air pollution and childhood lung function after implementation of strict air quality regulations in the 1990s. Objectives: To assess traffic-related pollution exposure and childhood lung function. Methods: We geocoded addresses for 614 mother–child pairs enrolled during pregnancy in the Boston area 1999–2002 and followed them until a mid-childhood visit (median age, 7.7). We calculated the proximity of the home to the nearest major roadway. We estimated first year of life, lifetime, and prior-year exposure to particulate matter with a diameter smaller than 2.5 μm (PM2.5) by a hybrid model using satellite-derived aerosol optical depth, and to black carbon (BC) by a land-use regression model. Measurements and Main Results: Residential proximity to roadway and prior-year and lifetime PM2.5 and BC exposure were all associated with lower FVC. Associations with FEV1 were also negative and proportionally similar. Pollution exposures were not associated with the FEV1/FVC ratio or bronchodilator response. Compared with distances greater than or equal to 400 m, living less than 100 m from a major roadway was associated with lower FVC (−98.6 ml; −176.3 to −21.0). Each 2 μg/m3 increment in prior-year PM2.5 was associated with lower FVC (−21.8 ml; −43.9 to 0.2) and higher odds of FEV1 less than 80% predicted (1.41; 1.03–1.93). Each 0.2 μg/m3 increment in prior-year BC was associated with a 38.9 ml (−70.4 to −7.3) lower FVC. Conclusions: Estimates of long-term exposure to ambient pollution, including proximity to major roadway, PM2.5, and BC (a traffic-related PM2.5 constituent), were associated with lower lung function in this Boston-area cohort of children with relatively low pollution exposures. PMID:26575800

  7. Lifetime Exposure to Ambient Pollution and Lung Function in Children.

    PubMed

    Rice, Mary B; Rifas-Shiman, Sheryl L; Litonjua, Augusto A; Oken, Emily; Gillman, Matthew W; Kloog, Itai; Luttmann-Gibson, Heike; Zanobetti, Antonella; Coull, Brent A; Schwartz, Joel; Koutrakis, Petros; Mittleman, Murray A; Gold, Diane R

    2016-04-15

    Few studies have examined associations between exposure to air pollution and childhood lung function after implementation of strict air quality regulations in the 1990s. To assess traffic-related pollution exposure and childhood lung function. We geocoded addresses for 614 mother-child pairs enrolled during pregnancy in the Boston area 1999-2002 and followed them until a mid-childhood visit (median age, 7.7). We calculated the proximity of the home to the nearest major roadway. We estimated first year of life, lifetime, and prior-year exposure to particulate matter with a diameter smaller than 2.5 μm (PM2.5) by a hybrid model using satellite-derived aerosol optical depth, and to black carbon (BC) by a land-use regression model. Residential proximity to roadway and prior-year and lifetime PM2.5 and BC exposure were all associated with lower FVC. Associations with FEV1 were also negative and proportionally similar. Pollution exposures were not associated with the FEV1/FVC ratio or bronchodilator response. Compared with distances greater than or equal to 400 m, living less than 100 m from a major roadway was associated with lower FVC (-98.6 ml; -176.3 to -21.0). Each 2 μg/m(3) increment in prior-year PM2.5 was associated with lower FVC (-21.8 ml; -43.9 to 0.2) and higher odds of FEV1 less than 80% predicted (1.41; 1.03-1.93). Each 0.2 μg/m(3) increment in prior-year BC was associated with a 38.9 ml (-70.4 to -7.3) lower FVC. Estimates of long-term exposure to ambient pollution, including proximity to major roadway, PM2.5, and BC (a traffic-related PM2.5 constituent), were associated with lower lung function in this Boston-area cohort of children with relatively low pollution exposures.

  8. Coexistence of Chronic Bronchitis in Chronic Obstructive Lung Disease.

    PubMed

    Mejza, Filip; Nastałek, Paweł; Mastalerz-Migas, Agnieszka; Doniec, Zbigniew; Skucha, Wojciech

    2018-05-12

    The incidence of chronic obstructive pulmonary disease (COPD) is on the rise worldwide. Chronic bronchitis is a frequent accompaniment of COPD, which increases the burden of COPD in affected individuals. The aim of this study was to characterize the phenotype of chronic bronchitis in COPD patients. The study was based on the survey data retrospectively retrieved from the Action Health-Lung Cancer Prophylaxis and Health Care Improvement screening program that concerned all the inhabitants, aged over 40, of the Proszowice administrative region situated in the Lesser Poland Voivodeship in southern Poland. Participants with the symptoms suggestive of a lung disease were subject to further evaluation. The findings were that 546 (13.3%) out of the 4105 individuals displayed spirometry features of COPD. Symptoms of chronic bronchitis were present in 92 (16.8%) out of the COPD afflicted persons. Chronic bronchitis was commoner in current smokers and its incidence increased with increasing severity of airway obstruction. In multivariate analysis, chronic bronchitis was independently related to lower FEV1, FVC, FEV1/FVC, and to dyspnea. In regression model, factors related to increased risk of chronic bronchitis were current smoking, asthma, and lower lung function. We conclude that COPD with coexisting chronic bronchitis is linked to severer dyspnea and worse lung function. Current smoking, asthma, and lower lung function are related to increased risk of chronic bronchitis accompanying COPD.

  9. Factors effecting impact of Aspergillus fumigatus sensitization in cystic fibrosis.

    PubMed

    Kanthan, Senthooran Kathirgama; Bush, Andrew; Kemp, Michael; Buchdahl, Roger

    2007-09-01

    The clinical impact of Aspergillus fumigatus (Af) sensitization in cystic fibrosis (CF) is controversial. We examined the effect of Af sensitization (Afs) on pulmonary function and growth using a retrospective cohort analysis over two 5-year study periods: 1996-2000 (19 Afs cases and 19 controls) and 2001-2005 (24 Afs cases and 23 controls). Sensitization was defined as Af specific radioallergosorbent test (RAST) >or= 17.5 iu/ml and total serum IgE level >or=150 iu/ml. We examined the impact of changing treatment schedules over these periods. Afs cases had lower median FEV(1) %predicted (%PR) compared to matched controls 1996: 67 versus 80, P < 0.01; 2001: 78 versus 93, P < 0.01. Afs cases in the 2001 cohort had a higher FEV(1) %PR compared to Afs cases in the 1996 cohort: 78 versus 67, P < 0.01. For the 1996 Afs cohort FEV(1) %PR fell significantly over 5 years but not for the 2001 Afs cohort. Af RAST and total IgE reflected the changes in pulmonary function. Children in the 2001 Afs cohort were prescribed significantly more oral antifungal treatment (odds ratio 4.3, 95%CI 1.2-15.7, P = 0.03). Afs children continue to have poorer lung function compared to controls but this observational, hypothesis generating study, suggests that the use of antifungal treatment is associated with better lung function. (c) 2007 Wiley-Liss, Inc.

  10. Higher mobility scores in patients with cystic fibrosis are associated with better lung function.

    PubMed

    Thobani, Aneesha; Alvarez, Jessica A; Blair, Shaina; Jackson, Kaila; Gottlieb, Eric R; Walker, Seth; Tangpricha, Vin

    2015-01-01

    The purpose of this study was to determine whether mobility and physical activity were associated with lung function in adults with cystic fibrosis (CF). This was a prospective cohort observational study in an urban, academic, specialized care center. Participants were ambulatory, nonhospitalized adults with CF. Mobility was assessed monthly by the Life-Space Assessment (LSA) questionnaire and quarterly by pedometer. Lung function was assessed by spirometry. Twenty-seven subjects participated. Subjects recorded mean pedometer steps of 20,213 ± 11,331 over three days and FEV1% predicted of 77.48% ± 22.60% over one year. The LSA score at enrollment was correlated with initial pedometer steps (r = 0.42 and P = 0.03), and mean LSA score over one year was correlated with mean number of steps (r = 0.51 and P = 0.007). LSA mobility and pedometer scores were correlated with FEV1% predicted at enrollment and throughout the study. Mobility and physical activity measured by LSA questionnaire and pedometer are positively associated with lung function in adults with CF. This study confirms the importance of mobility and physical activity and supports the utility of a simple office-based questionnaire as a measure of mobility in adults with CF.

  11. Childhood pneumonia increases risk for chronic obstructive pulmonary disease: the COPDGene study.

    PubMed

    Hayden, Lystra P; Hobbs, Brian D; Cohen, Robyn T; Wise, Robert A; Checkley, William; Crapo, James D; Hersh, Craig P

    2015-09-21

    Development of adult respiratory disease is influenced by events in childhood. The impact of childhood pneumonia on chronic obstructive pulmonary disease (COPD) is not well defined. We hypothesize that childhood pneumonia is a risk factor for reduced lung function and COPD in adult smokers. COPD cases and control smokers between 45-80 years old from the United States COPDGene Study were included. Childhood pneumonia was defined by self-report of pneumonia at <16 years. Subjects with lung disease other than COPD or asthma were excluded. Smokers with and without childhood pneumonia were compared on measures of respiratory disease, lung function, and quantitative analysis of chest CT scans. Of 10,192 adult smokers, 854 (8.4%) reported pneumonia in childhood. Childhood pneumonia was associated with COPD (OR 1.40; 95% CI 1.17-1.66), chronic bronchitis, increased COPD exacerbations, and lower lung function: post-bronchodilator FEV1 (69.1 vs. 77.1% predicted), FVC (82.7 vs. 87.4% predicted), FEV1/FVC ratio (0.63 vs. 0.67; p < 0.001 for all comparisons). Childhood pneumonia was associated with increased airway wall thickness on CT, without significant difference in emphysema. Having both pneumonia and asthma in childhood further increased the risk of developing COPD (OR 1.85; 95% CI 1.10-3.18). Children with pneumonia are at increased risk for future smoking-related lung disease including COPD and decreased lung function. This association is supported by airway changes on chest CT scans. Childhood pneumonia may be an important factor in the early origins of COPD, and the combination of pneumonia and asthma in childhood may pose the greatest risk. ClinicalTrials.gov, NCT00608764 (Active since January 28, 2008).

  12. Pulmonary function test in healthy school children of 8 to 14 years age in south Gujarat region, India

    PubMed Central

    Doctor, Tahera H.; Trivedi, Sangeeta S.; Chudasama, Rajesh K.

    2010-01-01

    Objective: To obtain reference values for FEV1, FVC, FEV1% and PEFR among children aged 8-14 years in south Gujarat region of India. Materials and Methods: This cross-sectional study was conducted among 655 normal healthy school children (408 boys and 247 girls) of Surat city aged 8 to 14 years studying in V to VII standard during November 2007 to April 2008. Height, weight, body surface area were measured. All included children were tested in a sitting position with the head straight after taking written consent from parents. Spirometry was done using the spirometer “Spirolab II” MIR 010. Spirometer used in the study facilitates the total valuation of lung function including forced vital capacity (FVC), forced expiratory volume in one second (FEV1), forced expiratory volume ratio in one second (FEV1%) and peak expiratory flow rate (PEFR). Results: FVC, FEV1 and PEFR were found to be statistically significant in the study groups. For FVC and FEV1, highest correlation was found with age in girls and height in boys. For FEV1%, significant negative correlation was found with age and height in both sexes, but positive correlation was found with surface area. Similarly, PEFR showed highest correlation with surface area in boys and girls. Conclusion: Variables such as FVC, FEV1 and PEFR show good positive correlation with height, age and body surface area in both sexes. There is a need to have regional values for the prediction of normal spirometric parameters in a country like India with considerable diversity. PMID:20931033

  13. Statistical Modeling of Disease Progression for Chronic Obstructive Pulmonary Disease Using Data from the ECLIPSE Study.

    PubMed

    Exuzides, Alex; Colby, Chris; Briggs, Andrew H; Lomas, David A; Rutten-van Mölken, Maureen P M H; Tabberer, Maggie; Chambers, Mike; Muellerova, Hana; Locantore, Nicholas; Risebrough, Nancy A; Ismaila, Afisi S; Gonzalez-McQuire, Sebastian

    2017-05-01

    To develop statistical models predicting disease progression and outcomes in chronic obstructive pulmonary disease (COPD), using data from ECLIPSE, a large, observational study of current and former smokers with COPD. Based on a conceptual model of COPD disease progression and data from 2164 patients, associations were made between baseline characteristics, COPD disease progression attributes (exacerbations, lung function, exercise capacity, and symptoms), health-related quality of life (HRQoL), and survival. Linear and nonlinear functional forms of random intercept models were used to characterize these relationships. Endogeneity was addressed by time-lagging variables in the regression models. At the 5% significance level, an exacerbation history in the year before baseline was associated with increased risk of future exacerbations (moderate: +125.8%; severe: +89.2%) and decline in lung function (forced expiratory volume in 1 second [FEV 1 ]) (-94.20 mL per year). Each 1% increase in FEV 1 % predicted was associated with decreased risk of exacerbations (moderate: -1.1%; severe: -3.0%) and increased 6-minute walk test distance (6MWD) (+1.5 m). Increases in baseline exercise capacity (6MWD, per meter) were associated with slightly increased risk of moderate exacerbations (+0.04%) and increased FEV 1 (+0.62 mL). Symptoms (dyspnea, cough, and/or sputum) were associated with an increased risk of moderate exacerbations (+13.4% to +31.1%), and baseline dyspnea (modified Medical Research Council score ≥2 v. <2) was associated with lower FEV 1 (-112.3 mL). A series of linked statistical regression equations have been developed to express associations between indicators of COPD disease severity and HRQoL and survival. These can be used to represent disease progression, for example, in new economic models of COPD.

  14. Biomarkers of World Trade Center Particulate Matter Exposure: Physiology of distal airway and blood biomarkers that predict FEV1 decline

    PubMed Central

    Weiden, Michael D.; Kwon, Sophia; Caraher, Erin; Berger, Kenneth I.; Reibman, Joan; Rom, William N.; Prezant, David J.; Nolan, Anna

    2016-01-01

    Biomarkers can be important predictors of disease severity and progression. The intense exposure to particulates and other toxins from the destruction of the World Trade Center (WTC) overwhelmed the lung’s normal protective barriers. The Fire Department of New York (FDNY) cohort not only had baseline pre-exposure lung function measures but also had serum samples banked soon after their WTC exposure. This well phenotyped group of highly exposed first responders is an ideal cohort for biomarker discovery and eventual validation. Disease progression was heterogeneous in this group in that some individuals subsequently developed abnormal lung function while others recovered. Airflow obstruction predominated in WTC exposed patients who were symptomatic. Multiple independent disease pathways may cause this abnormal FEV1 after irritant exposure. WTC exposure activates one or more of these pathways causing abnormal FEV1 in an individual. Our hypothesis was that serum biomarkers expressed within 6 months after World Trade Center (WTC) exposure reflect active disease pathways and predict subsequent development or protection from abnormal FEV1

  15. The reliability and utility of spirometry performed on people with asthma in community pharmacies.

    PubMed

    Lei Burton, Deborah; LeMay, Kate S; Saini, Bandana; Smith, Lorraine; Bosnic-Anticevich, Sinthia; Southwell, Phillipa; Cooke, Julie; Emmerton, Lynne; Stewart, Kay; Krass, Ines; Reddel, Helen; Armour, Carol

    2015-01-01

    To investigate the reliability and the utility of spirometry generated by community pharmacists participating in two large asthma intervention trials of 892 people. The Pharmacy Asthma Care Program (PACP) and the Pharmacy Asthma Management Service (PAMS) involved up to four visits to the pharmacy over 6 months for counseling and goal setting. Pharmacists performed spirometry according to ATS/ERS guidelines to inform management. The proportion of A-E, F quality tests, as per EasyOne QC grades, were recorded. Lung function results between visits and for participants referred/not referred to their general practitioner on the basis of spirometry were compared. Complete data from 2593 spirometry sessions were recorded, 68.5% of spirometry sessions achieved three acceptable tests with between-test repeatability of 150 ml or less (A or B quality), 96% of spirometry sessions included at least one test that met ATS/ERS acceptability criteria. About 39.1% of participants had FEV1/FVC values below the lower limit of normal (LNN), indicating a respiratory obstruction. As a result of the service, there was a significant increase in FEV1 and FEV1/FVC and asthma control. Lung function values were significantly poorer for participants referred to their general practitioner, compared with those not referred, on the basis of spirometry. Community pharmacists are able to reliably achieve spirometry results meeting ATS/ERS guidelines in people with asthma. Significant improvements in airway obstruction were demonstrated with the pharmacy services. Pharmacists interpreted lung function results to identify airway obstruction for referral, making this a useful technique for review of people with asthma in the community.

  16. Relationship between lung function and grip strength in older hospitalized patients: a pilot study

    PubMed Central

    Holmes, Sarah J; Allen, Stephen C; Roberts, Helen C

    2017-01-01

    Objective Older people with reduced respiratory muscle strength may be misclassified as having COPD on the basis of spirometric results. We aimed to evaluate the relationship between lung function and grip strength in older hospitalized patients without known airways disease. Methods Patients in acute medical wards were recruited who were aged ≥70 years; no history, symptoms, or signs of respiratory disease; Mini Mental State Examination ≥24; willing and able to consent to participate; and able to perform hand grip and forced spirometry. Data including lung function (forced expiratory volume in 1 second [FEV1], forced vital capacity [FVC], FEV1/FVC, peak expiratory flow rate [PEFR], and slow vital capacity [SVC]), grip strength, age, weight, and height were recorded. Data were analyzed using descriptive statistics and linear regression unadjusted and adjusted (for age, height, and weight). Results A total of 50 patients (20 men) were recruited. Stronger grip strength in men was significantly associated with greater FEV1, but this was attenuated by adjustment for age, height, and weight. Significant positive associations were found in women between grip strength and both PEFR and SVC, both of which remained robust to adjustment. Conclusion The association between grip strength and PEFR and SVC may reflect stronger patients generating higher intrathoracic pressure at the start of spirometry and pushing harder against thoracic cage recoil at end-expiration. Conversely, patients with weaker grip strength had lower PEFR and SVC. These patients may be misclassified as having COPD on the basis of spirometric results. PMID:28458532

  17. Use of tracheal auscultation for the assessment of bronchial responsiveness in asthmatic children.

    PubMed Central

    Sprikkelman, A. B.; Grol, M. H.; Lourens, M. S.; Gerritsen, J.; Heymans, H. S.; van Aalderen, W. M.

    1996-01-01

    BACKGROUND: It can be difficult to assess bronchial responsiveness in children because of their inability to perform spirometric tests reliably. In bronchial challenges lung sounds could be used to detect the required 20% fall in the forced expiratory volume in one second (FEV1). A study was undertaken to determine whether a change in lung sounds corresponded with a 20% fall in FEV1 after methacholine challenge, and whether the occurrence of wheeze was the most important change. METHODS: Fifteen children with asthma (eight boys) of mean age 10.8 years (range 8-15) were studied. All had normal chest auscultation before the methacholine challenge test. Lung sounds were recorded over the trachea for one minute and stored on tape. They were analysed directly and also scored blindly from the tape recording by a second investigator. Wheeze, cough, increase in respiratory rate, and prolonged expiration were assessed. RESULTS: The total cumulative methacholine dose causing a fall in FEV1 of 20% or more (PD20) was detected in 12 children by a change in lung sounds - in four by wheeze and in eight by cough, increased respiratory rate, and/or prolonged expiration. In two subjects altered lung sounds were detectable one dose step before PD20 was reached. In three cases in whom no fall in FEV1 occurred, no change in lung sounds could be detected at the highest methacholine dose. CONCLUSION: Changes in lung sounds correspond well with a 20% fall in FEV1 after methacholine challenge. Wheeze is an insensitive indicator for assessing bronchial responsiveness. Cough, increase in respiratory rate, and prolonged expiration occurs more frequently. PMID:8779140

  18. Changes in lung function of granite crushers exposed to moderately high silica concentrations: a 12 year follow up.

    PubMed Central

    Malmberg, P; Hedenström, H; Sundblad, B M

    1993-01-01

    45 granite crushers and 45 age and smoking matched referents underwent pulmonary function tests in 1976 and 1988. On average, the granite crushers at follow up had worked for 22 years, were 52 (range 36-78) years old, and had inhaled a cumulated amount of 7 mg of silica in the respirable dust fraction. Between 1976 and 1988 the average concentration of respirable quartz in air was 0.16 mg/m3 (threshold limit value (TLV) = 0.10 mg/m3). In 1988 the granite crushers had somewhat lower forced expiratory flows (forced expiratory volume in one second/vital capacity (FEV1/VC) -4.5% and forced midexpiratory flow FEF50 -15%) compared with the referents and a more uneven ventilation distribution (17% higher slope of phase III in the nitrogen single breath curve). Five smoking granite crushers, but none of the referents, had an FEV1 < 80% of the predicted. During the 12 year interval the granite crushers had--compared with the matched referents--a greater decrease in FEV1 (-4.6%), FEV1/VC (-5.4%), maximal expiratory flow, (-8%) and FEF50 (-14%), and a larger increase in phase III and static compliance (p < 0.02 in all variables). The functional changes suggest the presence of airways obstruction and increased compliance of the lungs. Exposure to silica at concentrations of about twice the present TLV was thus associated with airways obstruction and loss of elastic recoil rather than fibrosis and a restrictive function loss as seen in silicosis. The changes were on average small, but in some tobacco smokers more pronounced changes were found. PMID:8398859

  19. Advanced glycation end products are elevated in cystic fibrosis-related diabetes and correlate with worse lung function.

    PubMed

    Hunt, William R; Helfman, Beth R; McCarty, Nael A; Hansen, Jason M

    2016-09-01

    The onset of cystic fibrosis-related diabetes (CFRD) exacerbates lung function decline and increases mortality. One pathway that may worsen the lung dysfunction associated with CFRD is that of the receptor for advanced glycation end products (RAGE) and its ligands. Human plasma was obtained from age-matched healthy, CF and CFRD patients. Plasma RAGE ligands (i.e. advanced glycation end products, S100A12, and high-mobility group protein B1) and soluble RAGE (sRAGE) levels were measured. CFRD patients had elevated plasma levels of AGEs and S100A12. Soluble RAGE, a RAGE ligand decoy receptor, was not significantly different between groups. Plasma AGE levels and S100A12 levels had significantly negative correlations with FEV1. AGEs are significantly elevated in CFRD and correlate negatively with FEV1. CFRD patients did not have significant increases in the decoy sRAGE, suggesting there may be heightened binding and activation of RAGE in CFRD exacerbating activation of proinflammatory pathways. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  20. Intrapulmonary percussive ventilation improves lung function in cystic fibrosis patients chronically colonized with Pseudomonas aeruginosa: a pilot cross-over study.

    PubMed

    Dingemans, Jozef; Eyns, Hanneke; Willekens, Julie; Monsieurs, Pieter; Van Houdt, Rob; Cornelis, Pierre; Malfroot, Anne; Crabbé, Aurélie

    2018-06-01

    High levels of shear stress can prevent and disrupt Pseudomonas aeruginosa biofilm formation in vitro. Intrapulmonary percussive ventilation (IPV) could be used to introduce shear stress into the lungs of cystic fibrosis (CF) patients to disrupt biofilms in vivo. We performed a first-of-its-kind pilot clinical study to evaluate short-term IPV therapy at medium (200 bursts per minute, bpm) and high frequency (400 bpm) as compared to autogenic drainage (AD) on lung function and the behavior of P. aeruginosa in the CF lung in four patients who are chronically colonized by P. aeruginosa. A significant difference between the three treatment groups was observed for both the forced expiratory volume in 1 s (FEV1) and the forced vital capacity (FVC) (p < 0.05). More specifically, IPV at high frequency significantly increased FEV1 and FVC compared to AD (p < 0.05) and IPV at medium frequency (p < 0.001). IPV at high frequency enhanced the expression levels of P. aeruginosa planktonic marker genes, which was less pronounced with IPV at medium frequency or AD. In conclusion, IPV at high frequency could potentially alter the behavior of P. aeruginosa in the CF lung and improve lung function. The trail was retrospectively registered at the ISRCTN registry on 6 June 2013, under trial registration number ISRCTN75391385.

  1. Relationship between FEV1 and Cardiovascular Risk Factors in General Population without Airflow Limitation.

    PubMed

    Lee, Jeong Hyeon; Kang, Yun-Seong; Jeong, Yun-Jeong; Yoon, Young-Soon; Kwack, Won Gun; Oh, Jin Young

    2016-01-01

    Purpose. We aimed to determine the value of lung function measurement for predicting cardiovascular (CV) disease by evaluating the association between FEV1 (%) and CV risk factors in general population. Materials and Methods. This was a cross-sectional, retrospective study of subjects above 18 years of age who underwent health examinations. The relationship between FEV1 (%) and presence of carotid plaque and thickened carotid IMT (≥0.8 mm) was analyzed by multiple logistic regression, and the relationship between FEV1 (%) and PWV (%), and serum uric acid was analyzed by multiple linear regression. Various factors were adjusted by using Model 1 and Model 2. Results. 1,003 subjects were enrolled in this study and 96.7% ( n = 970) of the subjects were men. In both models, the odds ratio of the presence of carotid plaque and thickened carotid IMT had no consistent trend and statistical significance. In the analysis of the PWV (%) and uric acid, there was no significant relationship with FEV1 (%) in both models. Conclusion. FEV1 had no significant relationship with CV risk factors. The result suggests that FEV1 may have no association with CV risk factors or may be insensitive to detecting the association in general population without airflow limitation.

  2. Pulmonary Function Testing After Stereotactic Body Radiotherapy to the Lung

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bishawi, Muath; Kim, Bong; Moore, William H.

    2012-01-01

    Purpose: Surgical resection remains the standard of care for operable early-stage non-small-cell lung cancer (NSCLC). However, some patients are not fit for surgery because of comorbidites such as chronic obstructive pulmonary disease (COPD) and other medical conditions. We aimed to evaluate pulmonary function and tumor volume before and after stereotactic body radiotherapy (SBRT) for patients with and without COPD in early-stage lung cancer. Methods and Materials: A review of prospectively collected data of Stage I and II lung cancers, all treated with SBRT, was performed. The total SBRT treatment was 60 Gy administered in three 20 Gy fractions. The patientsmore » were analyzed based on their COPD status, using their pretreatment pulmonary function test cutoffs as established by the American Thoracic Society guidelines (forced expiratory volume [FEV]% {<=}50% predicted, FEV%/forced vital capacity [FVC]% {<=}70%). Changes in tumor volume were also assessed by computed tomography. Results: Of a total of 30 patients with Stage I and II lung cancer, there were 7 patients in the COPD group (4 men, 3 women), and 23 in t he No-COPD group (9 men, 14 women). At a mean follow-up time of 4 months, for the COPD and No-COPD patients, pretreatment and posttreatment FEV% was similar: 39 {+-} 5 vs. 40 {+-} 9 (p = 0.4) and 77 {+-} 0.5 vs. 73 {+-} 24 (p = 0.9), respectively. The diffusing capacity of the lungs for carbon monoxide (DL{sub CO}) did significantly increase for the No-COPD group after SBRT treatment: 60 {+-} 24 vs. 69 {+-} 22 (p = 0.022); however, DL{sub CO} was unchanged for the COPD group: 49 {+-} 13 vs. 50 {+-} 14 (p = 0.8). Although pretreatment tumor volume was comparable for both groups, tumor volume significantly shrank in the No-COPD group from 19 {+-} 24 to 9 {+-} 16 (p < 0.001), and there was a trend in the COPD patients from 12 {+-} 9 to 6 {+-} 5 (p = 0.06). Conclusion: SBRT did not seem to have an effect on FEV{sub 1} and FVC, but it shrank tumor volume and improved DL{sub CO} for patients without COPD.« less

  3. Global DNA hypomethylation has no impact on lung function or serum inflammatory and fibrosis cytokines in asbestos-exposed population.

    PubMed

    Yu, Min; Lou, Jianlin; Xia, Hailing; Zhang, Min; Zhang, Yixiao; Chen, Junqiang; Zhang, Xing; Ying, Shibo; Zhu, Lijin; Liu, Lihong; Jia, Guang

    2017-04-01

    To examine the effect of asbestos exposure on global DNA methylation and determine whether lung function and inflammatory and fibrosis biomarkers are correlated with the methylation state. A total of 26 healthy subjects without asbestos exposure (Group 1), 47 healthy subjects with exposure (Group 2), and 52 subjects with benign asbestos-related disorders (ARDs) (Group 3) participated in this cross-sectional study. Blood global 5-methylcytosine (5mC) and serum TNF-α, collagen IV, CCL5 and CC16 concentrations were analyzed using enzyme-linked immunosorbent assay-like assays. Spirometric maneuvers were performed to assess lung function. Decreased 5mC levels were observed in Groups 2 and 3 compared to Group 1, irrespective of lung function (p < 0.01). There was no significant change in 5mC between Groups 2 and 3. Overall, 5mC was negatively correlated with CCL5 and collagen IV (p < 0.05), but no significant inverse relationship was found between 5mC and CCL5 or collagen IV in each group. Additionally, both 5mC and CC16 were inversely associated with FEV1/FVC% (p = 0.001, adjusted R 2  = 0.145) for non-smokers, and consistently significant inverse relationships were found between CC16 and FEV1/FVC%, independent of asbestos exposure. Asbestos exposure causes global DNA hypomethylation. DNA hypomethylation has no influence on serum biomarkers and lung function in asbestos-exposed population with or without pleural and pulmonary parenchymal abnormalities.

  4. Chronic obstructive pulmonary disease in Welsh slate miners.

    PubMed

    Reynolds, C J; MacNeill, S J; Williams, J; Hodges, N G; Campbell, M J; Newman Taylor, A J; Cullinan, P

    2017-01-01

    Exposure to respirable crystalline silica (RCS) causes emphysema, airflow limitation and chronic obstructive pulmonary disease (COPD). Slate miners are exposed to slate dust containing RCS but their COPD risk has not previously been studied. To study the cumulative effect of mining on lung function and risk of COPD in a cohort of Welsh slate miners and whether these were independent of smoking and pneumoconiosis. The study was based on a secondary analysis of Medical Research Council (MRC) survey data. COPD was defined as forced expiratory volume in 1 s/forced vital capacity (FEV 1 /FVC) ratio <0.7. We created multivariable models to assess the association between mining and lung function after adjusting for age and smoking status. We used linear regression models for FEV 1 and FVC and logistic regression for COPD. In the original MRC study, 1255 men participated (726 slate miners, 529 unexposed non-miners). COPD was significantly more common in miners (n = 213, 33%) than non-miners (n = 120, 26%), P < 0.05. There was no statistically significant difference in risk of COPD between miners and non-miners when analysis was limited to non-smokers or those without radiographic evidence of pneumoconiosis. After adjustment for smoking, slate mining was associated with a reduction in %predicted FEV 1 [β coefficient = -3.97, 95% confidence interval (CI) -6.65, -1.29] and FVC (β coefficient = -2.32, 95% CI -4.31, -0.33) and increased risk of COPD (odds ratio: 1.38, 95% CI 1.06, 1.81). Slate mining may reduce lung function and increase the incidence of COPD independently of smoking and pneumoconiosis. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Exposure to ammonia and acute respiratory effects in a urea fertilizer factory.

    PubMed

    Rahman, Md Hamidur; Bråtveit, Magne; Moen, Bente E

    2007-01-01

    Personal exposures to ammonia and acute respiratory effects were determined in workers at a urea fertilizer factory in Bangladesh. Full-shift personal exposure to ammonia was measured using a PAC III direct reading instrument and Drager diffusion tubes. Respiratory symptoms were elicited by a questionnaire study (n = 113), and preshift and postshift lung function (FVC, FEV1, and PEFR) were tested using spirometry (n = 88). Urea plant workers had higher mean exposure to ammonia and prevalence of acute respiratory symptoms than did workers in the ammonia plant. The symptoms with highest prevalence in the urea plant were chest tightness (33%) and cough (28%). FVC and FEV1 decreased significantly across the work shift among urea plant workers. The higher level of exposure to ammonia in the urea plant was associated with an increased prevalence of respiratory symptoms and an acute decline in lung function.

  6. Pulmonary function in advanced uncomplicated singleton and twin pregnancy.

    PubMed

    Siddiqui, Anwar Hasan; Tauheed, Nazia; Ahmad, Aquil; Mohsin, Zehra

    2014-01-01

    Pregnancy brings about significant changes in respiratory function, as evidenced by alterations in lung volumes and capacities, which are attributable to the mechanical impediment caused by the growing foetus. This study was undertaken in order to identify changes in respiratory function during normal pregnancy and to determine whether such changes are more pronounced in twin pregnancy than in singleton pregnancy. Respiratory function was assessed in 50 women with twin pregnancies and in 50 women with singleton pregnancies (during the third trimester in both groups), as well as in 50 non-pregnant women. We measured the following pulmonary function test parameters: FVC; FEV1; PEF rate; FEV1/FVC ratio; FEF25-75%; and maximal voluntary ventilation. All respiratory parameters except the FEV1/FVC ratio were found to be lower in the pregnant women than in the non-pregnant women. We found no significant differences between women with twin pregnancies and those with singleton pregnancies, in terms of respiratory function. Despite its higher physiological demands, twin pregnancy does not appear to impair respiratory function to any greater degree than does singleton pregnancy.

  7. Changes in Lung Function and Chylous Effusions in Patients With Lymphangioleiomyomatosis Treated With Sirolimus

    PubMed Central

    Taveira-DaSilva, Angelo M.; Hathaway, Olanda; Stylianou, Mario; Moss, Joel

    2011-01-01

    Background Lymphangioleiomyomatosis (LAM) is a disorder that affects women and is characterized by cystic lung destruction, chylous effusions, lymphangioleiomyomas, and angiomyolipomas. It is caused by proliferation of abnormal smooth muscle–like cells. Sirolimus is a mammalian target of rapamycin inhibitor that has been reported to decrease the size of neoplastic growths in animal models of tuberous sclerosis complex and to reduce the size of angiomyolipomas and stabilize lung function in humans. Objective To assess whether sirolimus therapy is associated with improvement in lung function and a decrease in the size of chylous effusions and lymphangioleiomyomas in patients with LAM. Design Observational study. Setting The National Institutes of Health Clinical Center. Patients 19 patients with rapidly progressing LAM or chylous effusions. Intervention Treatment with sirolimus. Measurements Lung function and the size of chylous effusions and lymphangioleiomyomas before and during sirolimus therapy. Results Over a mean of 2.5 years before beginning sirolimus therapy, the mean (±SE) FEV1 decreased by 2.8% ± 0.8% predicted and diffusing capacity of the lung for carbon monoxide (DLCO) decreased by 4.8% ± 0.9% predicted per year. In contrast, over a mean of 2.6 years of sirolimus therapy, the mean (± SE) FEV1 increased by 1.8% ± 0.5% predicted and DLCO increased by 0.8% ± 0.5% predicted per year (P < 0.001). After beginning sirolimus therapy, 12 patients with chylous effusions and 11 patients with lymphangioleiomyomas experienced almost complete resolution of these conditions. In 2 of the 12 patients, sirolimus therapy enabled discontinuation of pleural fluid drainage. Limitations This was an observational study. The resolution of effusions may have affected improvements in lung function. Conclusion Sirolimus therapy is associated with improvement or stabilization of lung function and reduction in the size of chylous effusions and lymphangioleiomyomas in patients with LAM. Primary Funding Source Intramural Research Program, National Heart, Lung, and Blood Institute, National Institutes of Health. PMID:21690594

  8. Indacaterol and glycopyrronium versus indacaterol on body plethysmography measurements in COPD-a randomised controlled study.

    PubMed

    Salomon, Joerg; Stolz, Daiana; Domenighetti, Guido; Frey, Jean-Georges; Turk, Alexander J; Azzola, Andrea; Sigrist, Thomas; Fitting, Jean-William; Schmidt, Ulrich; Geiser, Thomas; Wild, Corinne; Kostikas, Konstantinos; Clemens, Andreas; Brutsche, Martin

    2017-01-11

    Dual bronchodilator therapy is recommended for symptomatic patients with chronic obstructive pulmonary disease (COPD). There are limited data on effects of a combination of two long-acting bronchodilators on lung function including body plethysmography. This multicentre, randomised, double-blind, single-dose, cross-over, placebo-controlled study evaluated efficacy and safety of the free combination of indacaterol maleate (IND) and glycopyrronium bromide (GLY) versus IND alone on spirometric and body plethysmography parameters, including inspiratory capacity (IC), forced expiratory volume in 1 s (FEV 1 ), forced vital capacity (FVC), total lung capacity (TLC) and airway resistance (Raw) in moderate-to-severe COPD patients. Seventy-eight patients with FEV 1 % pred. (mean ± SD) 56 ± 13% were randomised. The combination of IND + GLY versus IND presented a numerically higher peak-IC (Δ = 0.076 L, 95% confidence interval [CI]: -0.010 - 0.161 L; p = 0.083), with a statistically significant difference in mean IC over 4 h (Δ = 0.054 L, 95%CI 0.022 - 0.086 L; p = 0.001). FEV 1 , FVC and Raw, but not TLC, were consistently significantly improved by IND + GLY compared to IND alone. Safety profiles of both treatments were comparable. The free combination of IND + GLY improved lung function parameters as evaluated by spirometry and body plethysmography, with a similar safety profile compared to IND alone. NCT01699685.

  9. Relationship between the baseline alveolar volume-to-total lung capacity ratio and airway responsiveness.

    PubMed

    Kaminsky, David A; Daud, Anees; Chapman, David G

    2014-10-01

    Ventilation heterogeneity (VH) has been linked to airway responsiveness (AR) based on various measures of VH involving inert gas washout, forced oscillation and lung imaging. We explore whether VH at baseline, as measured by the simple ratio of single breath alveolar volume to plethysmographically determined total lung capacity (VA/TLC), would correlate with AR as measured by methacholine challenge testing. We analysed data from spirometry, lung volumes, diffusing capacity and methacholine challenge to derive the VA/TLC and the dose-response slope (DRS) of forced expiratory volume in 1 s (DRS-FEV1) during methacholine challenge from 136 patients. We separated out airway closure versus narrowing by examining the DRS for forced vital capacity (DRS-FVC) and the DRS for FEV1/FVC (DRS-FEV1/FVC), respectively. Similarly, we calculated the DRS for sGaw (DRS-sGaw) as another measure of airway narrowing. We performed statistical analysis using Spearman rank correlation and multifactor linear regression using a backward stepwise modelling procedure. We found that the DRS-FEV1 correlated with baseline VA/TLC (rho = -0.26, P < 0.01), and VA/TLC and FEV1 were independently associated with DRS-FEV1 (R(2)  = 0.14, P = 0.01). In addition, VA/TLC was associated with both airway narrowing and closure in response to methacholine. These results confirm that baseline VA/TLC is associated with AR, and reflects both airway closure and airway narrowing following methacholine challenge. © 2014 Asian Pacific Society of Respirology.

  10. Long-term gas exchange characteristics as markers of deterioration in patients with cystic fibrosis

    PubMed Central

    2009-01-01

    Background and Aim In patients with cystic fibrosis (CF) the architecture of the developing lungs and the ventilation of lung units are progressively affected, influencing intrapulmonary gas mixing and gas exchange. We examined the long-term course of blood gas measurements in relation to characteristics of lung function and the influence of different CFTR genotype upon this process. Methods Serial annual measurements of PaO2 and PaCO2 assessed in relation to lung function, providing functional residual capacity (FRCpleth), lung clearance index (LCI), trapped gas (VTG), airway resistance (sReff), and forced expiratory indices (FEV1, FEF50), were collected in 178 children (88 males; 90 females) with CF, over an age range of 5 to 18 years. Linear mixed model analysis and binary logistic regression analysis were used to define predominant lung function parameters influencing oxygenation and carbon dioxide elimination. Results PaO2 decreased linearly from age 5 to 18 years, and was mainly associated with FRCpleth, (p < 0.0001), FEV1 (p < 0.001), FEF50 (p < 0.002), and LCI (p < 0.002), indicating that oxygenation was associated with the degree of pulmonary hyperinflation, ventilation inhomogeneities and impeded airway function. PaCO2 showed a transitory phase of low PaCO2 values, mainly during the age range of 5 to 12 years. Both PaO2 and PaCO2 presented with different progression slopes within specific CFTR genotypes. Conclusion In the long-term evaluation of gas exchange characteristics, an association with different lung function patterns was found and was closely related to specific genotypes. Early examination of blood gases may reveal hypocarbia, presumably reflecting compensatory mechanisms to improve oxygenation. PMID:19909502

  11. The respiratory health and lung function of Anglo-American children in a smelter town

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dodge, R.

    1983-02-01

    Cooper smelters are large, usually isolated, sources of air pollution. Arizona has several such plants on the periphery of small communities. The smelters emit predominantly sulfur oxides and particulates, and the residents of these communities intermittently are exposed to high concentrations (24-h sulfur dioxide (SO2) . 250 to 500 micrograms/m3) of smelter smoke but little other pollution. This study compared the respiratory health of Anglo-American school children who lived in one smelter community with children living in another small community in Arizona that was free of smelter air pollution. The prevalence of cough, as determined by questionnaire, was 25.6% inmore » the smelter town children and 14.3% in the nonsmelter town children (p less than 0.05). Pulmonary function at the study onset was equal in the two groups. Over the course of the 4 yr of study, lung function growth (measured as actual forced expiratory volume in one second (FEV1) after 4 yr of study minus predicted FEV1) was also equal in the smelter town and nonsmelter town children. These results suggest that children in smelter communities have slightly more cough when compared with children living in other communities, but no differences in initial lung function or lung function at yearly testing over the period of the study.« less

  12. Influence of lung function on course of disease and response to antibiotic therapy in adult primary care patients with acute cough: a post hoc analysis of patients enrolled in a prospective multicentre study.

    PubMed

    van Erp, Nicole; Little, Paul; Stuart, Beth; Moore, Michael; Thomas, Mike; Butler, Chris C; Hood, Kerenza; Coenen, Samuel; Goossens, Herman; Leven, Margareta; Verheij, Theo J M

    2014-09-25

    In acute cough patients, impaired lung function as present in chronic lung conditions like asthma and chronic obstructive pulmonary disease (COPD) are often thought to negatively influence course of disease, but clear evidence is lacking. To investigate the influence of lung function abnormalities on course of disease and response to antibiotic therapy in primary care patients with acute cough. A total of 3,104 patients with acute cough (⩽28 days) were included in a prospective observational study with a within-nested trial, of which 2,427 underwent spirometry 28-35 days after inclusion. Influence of the lung function abnormalities fixed obstruction (forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) ratio <0.7) and bronchodilator responsiveness (FEV1 increase of ⩾12% or 200 ml after 400 μg salbutamol) on symptom severity, duration and worsening were evaluated using uni- and multivariable regression models. Antibiotic use was defined as the reported use of antibiotics ⩾5 days in the first week. Interaction terms were calculated to investigate modifying effects of lung function on antibiotic effect. The only significant association was the effect of severe airway obstruction on symptom severity on days 2-4 (difference=0.31, 95% confidence interval (CI)=0.03-0.60, P=0.03). No evidence of a differential effect of lung function on the effect of antibiotics was found. Prior use of inhaled steroids was associated with a 30% slower resolution of symptoms rated 'moderately bad' or worse (hazard ratio=0.75, 95% CI=0.63-0.90, P=0.00). In adult patients with acute cough, lung function abnormalities were neither significantly associated with course of disease nor did they modify the effect of antibiotics.

  13. Age-related annual decline of lung function in patients with COPD.

    PubMed

    Kim, Soo Jung; Lee, Jinwoo; Park, Young Sik; Lee, Chang-Hoon; Yoon, Ho Il; Lee, Sang-Min; Yim, Jae-Joon; Kim, Young Whan; Han, Sung Koo; Yoo, Chul-Gyu

    2016-01-01

    According to the Fletcher-Peto curve, rate of decline in forced expiratory volume in 1-second (FEV1) accelerates as age increases. However, recent studies have not demonstrated that the rate of FEV1 decline accelerates with age among COPD patients. The objective of the study is to evaluate annual rate of FEV1 decline as age increases among COPD patients. In this retrospective cohort study, we enrolled COPD patients who were followed up at two tertiary care university hospitals from January 2000 to August 2013. COPD was defined as post-bronchodilator (BD) FEV1/forced vital capacity (FVC) of <0.7. All participants had more than two spirometries, including BD response. Age groups were categorized as follows: below versus above median age or four quartiles. A total of 518 participants (94.2% male; median age, 67 years; range, 42-90 years) were included. Mean absolute and predictive values of post-BD FEV1 were 1.57±0.62 L and 52.53%±18.29%, respectively. Distribution of Global initiative for Chronic Obstructive Lung Disease groups did not show statistical differences between age groups categorized by two different criteria. After grouping the population by age quartiles, the rate of FEV1 decline was faster among older patients than younger ones whether expressed as absolute value (-10.60±5.57 mL/year, -15.84±6.01 mL/year, -18.63±5.53 mL/year, 32.94±6.01 mL/year, respectively; P=0.048) or predicted value (-0.34%±0.19%/year, -0.53%±0.21%/year, -0.62%±0.19%/year, -1.26%±0.21%/year, respectively, P=0.010). As suggested conceptually by the Fletcher-Peto curve, annual FEV1 decline among COPD patients is accelerated among older patients than younger ones.

  14. Mouse allergen, lung function, and atopy in Puerto Rican children.

    PubMed

    Forno, Erick; Cloutier, Michelle M; Datta, Soma; Paul, Kathryn; Sylvia, Jody; Calvert, Deanna; Thornton-Thompson, Sherell; Wakefield, Dorothy B; Brehm, John; Hamilton, Robert G; Alvarez, María; Colón-Semidey, Angel; Acosta-Pérez, Edna; Canino, Glorisa; Celedón, Juan C

    2012-01-01

    To examine the relation between mouse allergen exposure and asthma in Puerto Rican children. Mus m 1, Der p 1, Bla g 2, and Fel d 1 allergens were measured in dust samples from homes of Puerto Rican children with (cases) and without (controls) asthma in Hartford, CT (n = 449) and San Juan (SJ), Puerto Rico (n = 678). Linear or logistic regression was used for the multivariate analysis of mouse allergen (Mus m 1) and lung function (FEV(1) and FEV(1)/FVC) and allergy (total IgE and skin test reactivity (STR) to ≥1 allergen) measures. Homes in SJ had lower mouse allergen levels than those in Hartford. In multivariate analyses, mouse allergen was associated with higher FEV(1) in cases in Hartford (+70.6 ml, 95% confidence interval (CI) = 8.6-132.7 ml, P = 0.03) and SJ (+45.1 ml, 95% CI =  -0.5 to 90.6 ml, P = 0.05). In multivariate analyses of controls, mouse allergen was inversely associated with STR to ≥1 allergen in non-sensitized children (odds ratio [OR] for each log-unit increment in Mus m 1 = 0.7, 95% CI = 0.5-0.9, P<0.01). In a multivariate analysis including all children at both study sites, each log-increment in mouse allergen was positively associated with FEV(1) (+28.3 ml, 95% CI = 1.4-55.2 ml, P = 0.04) and inversely associated with STR to ≥1 allergen (OR for each log-unit increment in Mus m 1 = 0.8, 95% CI = 0.6-0.9, P<0.01). Mouse allergen is associated with a higher FEV(1) and lower odds of STR to ≥1 allergen in Puerto Rican children. This may be explained by the allergen itself or correlated microbial exposures.

  15. Mouse Allergen, Lung Function, and Atopy in Puerto Rican Children

    PubMed Central

    Forno, Erick; Cloutier, Michelle M.; Datta, Soma; Paul, Kathryn; Sylvia, Jody; Calvert, Deanna; Thornton-Thompson, Sherell; Wakefield, Dorothy B.; Brehm, John; Hamilton, Robert G.; Alvarez, María; Colón-Semidey, Angel; Acosta-Pérez, Edna; Canino, Glorisa; Celedón, Juan C.

    2012-01-01

    Objective To examine the relation between mouse allergen exposure and asthma in Puerto Rican children. Methods Mus m 1, Der p 1, Bla g 2, and Fel d 1 allergens were measured in dust samples from homes of Puerto Rican children with (cases) and without (controls) asthma in Hartford, CT (n = 449) and San Juan (SJ), Puerto Rico (n = 678). Linear or logistic regression was used for the multivariate analysis of mouse allergen (Mus m 1) and lung function (FEV1 and FEV1/FVC) and allergy (total IgE and skin test reactivity (STR) to ≥1 allergen) measures. Results Homes in SJ had lower mouse allergen levels than those in Hartford. In multivariate analyses, mouse allergen was associated with higher FEV1 in cases in Hartford (+70.6 ml, 95% confidence interval (CI) = 8.6–132.7 ml, P = 0.03) and SJ (+45.1 ml, 95% CI =  −0.5 to 90.6 ml, P = 0.05). In multivariate analyses of controls, mouse allergen was inversely associated with STR to ≥1 allergen in non-sensitized children (odds ratio [OR] for each log-unit increment in Mus m 1 = 0.7, 95% CI = 0.5–0.9, P<0.01). In a multivariate analysis including all children at both study sites, each log-increment in mouse allergen was positively associated with FEV1 (+28.3 ml, 95% CI = 1.4–55.2 ml, P = 0.04) and inversely associated with STR to ≥1 allergen (OR for each log-unit increment in Mus m 1 = 0.8, 95% CI = 0.6–0.9, P<0.01). Conclusions Mouse allergen is associated with a higher FEV1 and lower odds of STR to ≥1 allergen in Puerto Rican children. This may be explained by the allergen itself or correlated microbial exposures. PMID:22815744

  16. Prevalence and prediction of exercise-induced oxygen desaturation in patients with chronic obstructive pulmonary disease.

    PubMed

    van Gestel, A J R; Clarenbach, C F; Stöwhas, A C; Teschler, S; Russi, E W; Teschler, H; Kohler, M

    2012-01-01

    Previous studies with small sample sizes reported contradicting findings as to whether pulmonary function tests can predict exercise-induced oxygen desaturation (EID). To evaluate whether forced expiratory volume in one second (FEV(1)), resting oxygen saturation (SpO(2)) and diffusion capacity for carbon monoxide (DLCO) are predictors of EID in chronic obstructive pulmonary disease (COPD). We measured FEV(1), DLCO, SpO(2) at rest and during a 6-min walking test as well as physical activity by an accelerometer. A drop in SpO(2) of >4 to <90% was defined as EID. To evaluate associations between measures of lung function and EID univariate and multivariate analyses were used and positive/negative predictive values were calculated. Receiver operating characteristic curve analysis was performed to determine the most useful threshold in order to predict/exclude EID. We included 154 patients with COPD (87 females). The mean FEV(1) was 43.0% (19.2) predicted and the prevalence of EID was 61.7%. The only independent predictor of EID was FEV(1) and the optimal cutoff value of FEV(1) was at 50% predicted (area under ROC curve, 0.85; p < 0.001). The positive predictive value of a threshold of FEV(1) <50% was 0.83 with a likelihood ratio of 3.03 and the negative predicting value of a threshold of FEV(1) ≥80% was 1.0. The severity of EID was correlated with daily physical activity (r = -0.31, p = 0.008). EID is highly prevalent among patients with COPD and can be predicted by FEV(1). EID seems to be associated with impaired daily physical activity which supports its clinical importance. Copyright © 2012 S. Karger AG, Basel.

  17. The training type influence on male elite athletes' ventilatory function.

    PubMed

    Durmic, Tijana; Lazovic Popovic, Biljana; Zlatkovic Svenda, Mirjana; Djelic, Marina; Zugic, Vladimir; Gavrilovic, Tamara; Mihailovic, Zoran; Zdravkovic, Marija; Leischik, Roman

    2017-01-01

    To assess and compare measured ventilatory volumes (forced expiratory volume in 1 s (FEV 1 ), peak expirium flow (PEF) and maximal voluntary ventilation (MVV)), ventilatory function capacities (forced vital capacity (FVC) and vital capacity (VC)) and FEV 1 /VC ratio in a sample of power and endurance elite athletes and their age-matched and sex-matched sedentary control group. A cross-sectional study was applied on male elite athletes (n=470) who were classified according to the type of the predominantly performed exercise in the following way: group 1: endurance group (EG=270), group 2: power athletes group (SG=200) and group 3: sedentary control group (CG=100). The lung VC, FVC, FEV 1 , FEV 1 /FVC ratio, PEF and MVV were measured in all of the observed subjects, who were also classified with regard to body mass index (BMI) and the percentage of the body fat (BF%). The CG had the highest BF% value, while the endurance group had the lowest BMI and BF% value, which is significantly different from the other two groups (p<0.05). The observed values of VC, FVC and FEV 1 in the EG were significantly higher than those from the other two groups (p<0.05). There were no differences concerning the observed FEV 1 /FVC ratio. A continued endurance physical activity leads to adaptive changes in spirometric parameters (VC, FVC and FEV 1 ), highlighting the fact that there is a need for specific consideration of different respiratory 'pattern' development in different types of sport, which also has to be further evaluated.

  18. The effect of methacholine-induced acute airway narrowing on lung sounds in normal and asthmatic subjects.

    PubMed

    Schreur, H J; Vanderschoot, J; Zwinderman, A H; Dijkman, J H; Sterk, P J

    1995-02-01

    The association between lung sound alterations and airways obstruction has long been recognized in clinical practice, but the precise pathophysiological mechanisms of this relationship have not been determined. Therefore, we examined the changes in lung sounds at well-defined levels of methacholine-induced airway narrowing in eight normal and nine asthmatic subjects with normal baseline lung function. All subjects underwent phonopneumography at baseline condition and at > or = 20% fall in forced expiratory volume in one second (FEV1), and in asthmatic subjects also at > or = 40% fall in FEV1. Lung sounds were recorded at three locations on the chest wall during standardized quiet breathing, and during maximal forced breathing. Airflow-dependent power spectra were computed using fast Fourier transform. For each spectrum, we determined the intensity and frequency content of lung sounds, together with the extent of wheezing. The results were analysed using analysis of variance (ANOVA). During acute airway narrowing, the intensity and frequency content of the recorded sounds, as well as the extent of wheezing, were higher than at baseline in both groups of subjects. At similar levels of obstruction, both the pitch and the change in sound intensity with airflow were higher in asthmatics than in normal subjects. Wheezing, being nondiscriminative between the subject groups at baseline, was more prominent in asthmatics than in normal subjects at 20% fall in FEV1. We conclude that, at given levels of acute airway narrowing, lung sounds differ between asthmatics and normal subjects. This suggests that airflow-standardized phonopneumography is a sensitive method for detecting abnormalities in airway dynamics in asthma.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Cotton dust and endotoxin exposure-response relationships in cotton textile workers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kennedy, S.M.; Christiani, D.C.; Eisen, E.A.

    Endotoxin exposure has been implicated in the etiology of lung disease in cotton workers. We investigated this potential relationship in 443 cotton workers from 2 factories in Shanghai and 439 control subjects from a nearby silk mill. A respiratory questionnaire was administered and pre- and postshift forced expiratory volume (FVC) and flow in one second (FEV1) were determined for each worker. Multiple area air samples were analyzed for total elutriated dust concentration (range: 0.15 to 2.5 mg/m3) and endotoxin (range: 0.002 to 0.55 microgram U.S. Reference Endotoxin/m3). The cotton worker population was stratified by current and cumulative dust or endotoxinmore » exposure. Groups were compared for FEV1, FVC, FEV1/FVC%, % change in FEV1 over the shift (delta FEV1%), and prevalences of chronic bronchitis and byssinosis, and linear and logistic regression models were constructed. No dose-response relationships were demonstrated comparing dust concentration to any pulmonary function or symptom variable. A dose-response trend was seen with the current endotoxin level and FEV1, delta FEV1%, and the prevalence of byssinosis and chronic bronchitis, except for the highest exposure level group in which a reversal of the trend was seen. The regression coefficients for current endotoxin exposure were significant (p less than 0.05) in the models for FEV1 and chronic bronchitis but not in the models for delta FEV1% (i.e., acute change in FEV1) or byssinosis prevalence. The coefficient for dust level was never significant in the models.« less

  20. Forskolin compared with beclomethasone for prevention of asthma attacks: a single-blind clinical trial.

    PubMed

    Huerta, M; Urzúa, Z; Trujillo, X; González-Sánchez, R; Trujillo-Hernández, B

    2010-01-01

    This single-blind study compared the efficacy of oral forskolin versus inhaled beclomethasone for mild or moderately persistent adult asthma. Patients were randomly assigned to receive forskolin (one 10-mg capsule orally per day; n = 30) or beclomethasone (two 50 microg inhalations every 12 h; n = 30) for 2 months. No statistically significant improvement occurred in any lung function parameter in the forskolin-treated patients. Subjects in the beclomethasone-treated group presented a slight but statistically significant improvement in percentage forced expiratory volume in 1 s (FEV(1)), percentage forced expiratory flow in the middle (25 - 75%) expiratory phase (FEF(25 - 75%)) and percentage forced vital capacity (FVC) after 2 months of treatment, though the improvement in absolute values for FEV(1), FEF(25 - 75%), FVC and FEV(1):FVC did not reach statistical significance. There was no statistically significant difference between the forskolin and beclomethasone treatment groups for any lung function parameter at baseline or after treatment. None of the beclomethasone-treated patients had an asthma attack and one forskolin-treated patient had a mild asthma attack during the 2-month study period. More studies are needed in adult asthma patients to confirm whether forskolin may be a useful preventive treatment for mild or moderately persistent adult asthma.

  1. Cost and effectiveness of lung lobectomy by video-assisted thoracic surgery for lung cancer

    PubMed Central

    Mafé, Juan J.; Planelles, Beatriz; Asensio, Santos; Cerezal, Jorge; Inda, María-del-Mar; Lacueva, Javier; Esteban, Maria-Dolores; Hernández, Luis; Martín, Concepción; Baschwitz, Benno

    2017-01-01

    Background Video-assisted thoracic surgery (VATS) emerged as a minimally invasive surgery for diseases in the field of thoracic surgery. We herein reviewed our experience on thoracoscopic lobectomy for early lung cancer and evaluated Health System use. Methods A cost-effectiveness study was performed comparing VATS vs. open thoracic surgery (OPEN) for lung cancer patients. Demographic data, tumor localization, dynamic pulmonary function tests [forced vital capacity (FVC), forced expiratory volume in one second (FEV1), diffusion capacity (DLCO) and maximal oxygen uptake (VO2max)], surgical approach, postoperative details, and complications were recorded and analyzed. Results One hundred seventeen patients underwent lung resection by VATS (n=42, 36%; age: 63±9 years old, 57% males) or OPEN (n=75, 64%; age: 61±11 years old, 73% males). Pulmonary function tests decreased just after surgery with a parallel increasing tendency during first 12 months. VATS group tended to recover FEV1 and FVC quicker with significantly less clinical and post-surgical complications (31% vs. 53%, P=0.015). Costs including surgery and associated hospital stay, complications and costs in the 12 months after surgery were significantly lower for VATS (P<0.05). Conclusions The VATS approach surgery allowed earlier recovery at a lower cost than OPEN with a better cost-effectiveness profile. PMID:28932560

  2. Indoor NO2 air pollution and lung function of professional cooks.

    PubMed

    Arbex, M A; Martins, L C; Pereira, L A A; Negrini, F; Cardoso, A A; Melchert, W R; Arbex, R F; Saldiva, P H N; Zanobetti, A; Braga, A L F

    2007-04-01

    Studies of cooking-generated NO2 effects are rare in occupational epidemiology. In the present study, we evaluated the lung function of professional cooks exposed to NO2 in hospital kitchens. We performed spirometry in 37 cooks working in four hospital kitchens and estimated the predicted FVC, FEV1 and FEF(25-75), based on age, sex, race, weight, and height, according to Knudson standards. NO2 measurements were obtained for 4 consecutive days during 4 different periods at 20-day intervals in each kitchen. Measurements were performed inside and outside the kitchens, simultaneously using Palm diffusion tubes. A time/exposure indicator was defined as representative of the cumulative exposure of each cook. No statistically significant effect of NO2 exposure on FVC was found. Each year of work as a cook corresponded to a decrease in predicted FEV1 of 2.5% (P = 0.046) for the group as a whole. When smoking status and asthma were included in the analysis the effect of time/exposure decreased about 10% and lost statistical significance. On predicted FEF(25-75), a decrease of 3.5% (P = 0.035) was observed for the same group and the inclusion of controllers for smoking status and asthma did not affect the effects of time/exposure on pulmonary function parameter. After a 10-year period of work as cooks the participants of the study may present decreases in both predicted FEV1 and FEF(25-75) that can reach 20 and 30%, respectively. The present study showed small but statistically significant adverse effects of gas stove exposure on the lung function of professional cooks.

  3. The connection between chronic obstructive pulmonary disease symptoms and hyperinflation and its impact on exercise and function.

    PubMed

    Cooper, Christopher B

    2006-10-01

    Forced expiratory volume in 1 second (FEV1) has served as an important diagnostic measurement of chronic obstructive pulmonary disease (COPD) but has not been found to correlate with patient-centered outcomes such as exercise tolerance, dyspnea, or health-related quality of life. It has not helped us understand why some patients with severe FEV1 impairment have better exercise tolerance compared with others with similar FEV1 values. Hyperinflation, or air trapping caused by expiratory flow limitation, causes operational lung volumes to increase and even approach the total lung capacity (TLC) during exercise. Some study findings suggest that a dyspnea limit is reached when the end-inspiratory lung volume encroaches within approximately 500 mL of TLC. The resulting limitation in daily physical activity establishes a cycle of decline that includes physical deconditioning (elevated blood lactic acid levels at lower levels of exercise) and worsening dyspnea. Hyperinflation is reduced by long-acting bronchodilators that reduce airways resistance. The deflation of the lungs, in turn, results in an increased inspiratory capacity. For example, the once-daily anticholinergic bronchodilator tiotropium increases inspiratory capacity, 6-minute walk distance, and cycle exercise endurance time, and it decreases isotime fatigue or dyspnea. Pulmonary rehabilitation and oxygen therapy both reduce ventilatory requirements and improve breathing efficiency, thereby reducing hyperinflation and improving exertional dyspnea. Thus, hyperinflation is directly associated with patient-centered outcomes such as dyspnea and exercise limitation. Furthermore, therapeutic interventions--including pharmacotherapy and lung volume--reduction surgery--that reduce hyperinflation improve these outcomes.

  4. The effect of dietary antioxidant on the COPD risk: the community-based KoGES (Ansan–Anseong) cohort

    PubMed Central

    Joshi, Pankaj; Kim, Woo Jin; Lee, Sang-Ah

    2015-01-01

    Background Dietary antioxidants have been suggested to have protective role against chronic obstructive pulmonary disease (COPD), but few prospective studies examined this relationship. The prospective study was conducted to evaluate the effect of dietary antioxidants on COPD risk and lung function in the Korean population. Methods The data were collected from the community-based Korean Genome Epidemiology Study (KoGES) cohort. To diagnose COPD, forced expiratory volume (FEV1) and forced vital capacity (FVC) were measured by spirometry. The dietary intake of antioxidant vitamins was estimated from validated Food-Frequency Questionnaire. For the analysis, 325 COPD patients and 6,781 at risk subjects were selected from the cohort of 10,038 subjects. Multiple logistic regression models were used to examine the odds ratio (OR) after adjusting for age, sex, marital status, income, history of asthma, history of tuberculosis, and smoking. Results The risk of COPD was positively associated with aging, low education, low household income, lower body mass index, and cigarette smoking. The risk of COPD decreased with increase in the dietary vitamin C (ORQ1 vs Q5=0.66, Ptrend=0.03) and vitamin E (ORQ1 vs Q5=0.56, Ptrend=0.05) intake, predominantly, in men (Ptrend=0.01 and 0.05 for vitamins C and E, respectively). In addition, the lung function was significantly improved with increase in vitamins C (FEV1, P=0.04; FVC, P=0.03) and E (FEV1, P=0.03; FVC, P=0.04) intake. No statistically significant interactions were observed between smoking and vitamin C or E intake in relation to COPD risk among men. Conclusion Our results suggest the independent beneficial effect of antioxidants, particularly vitamins C and E, on COPD risk and lung function in men. PMID:26504380

  5. Pulmonary functions of narghile smokers compared to cigarette smokers: a case-control study.

    PubMed

    Ben Saad, Helmi; Khemiss, Mehdi; Nhari, Saida; Ben Essghaier, Mejda; Rouatbi, Sonia

    2013-01-01

    Studies of the lung function profiles of exclusive narghile smokers (ENS) are few, have some methodological limits, and present contradictory conclusions. The present study aimed to compare the plethysmographic profiles of ENS with age- and height-matched exclusive cigarette smokers (ECS). Males aged 35-60 living in Sousse, Tunisia, who have been smoking narghile exclusively for more than 10 narghile-years (n = 36) or cigarettes exclusively for more than 10 pack-years (n = 106) were recruited to participate in this case-control study. The anthropometric and plethysmographic data were measured according to international recommendations using a body plethysmograph (ZAN 500 Body II, Meβgreräte GmbH, Germany). Large-airway-obstructive-ventilatory-defect (LAOVD) was defined as: first second forced expiratory volume/forced vital capacity (FEV1/FVC) below the lower-limit-of-normal (LLN). Restrictive-ventilatory-defect (RVD) was defined as total lung capacity < LLN. Lung hyperinflation was defined as residual volume > upper-limit-of-normal. Student t-test and χ(2) test were used to compare plethysmographic data and profiles of the two groups. The subjects in the ENS and ECS groups are well matched in age (45±7 vs. 47±5 years) and height (1.73±0.06 vs. 1.72±0.06 m) and used similar quantities of tobacco (36±22 narghile-years vs. 35±19 pack-years). Compared to the ENS group, the ECS group had significantly lower FEV1 (84±12 vs. 60±21%), FVC (90±12 vs. 76±18%), and FEV1/FVC (99±7 vs. 83±17%). The two groups had similar percentages of RVD (31 vs. 36%), while the ECS group had a significantly higher percentage of LAOVD (8 vs. 58%) and lung hyperinflation (36 vs.57%). Chronic exclusive narghile smoking has less adverse effects on pulmonary function tests than chronic exclusive cigarette smoking.

  6. Pulmonary functions of narghile smokers compared to cigarette smokers: a case-control study.

    PubMed

    Saad, Helmi Ben; Khemiss, Mehdi; Nhari, Saida; Essghaier, Mejda Ben; Rouatbi, Sonia

    2013-01-01

    Background Studies of the lung function profiles of exclusive narghile smokers (ENS) are few, have some methodological limits, and present contradictory conclusions. The present study aimed to compare the plethysmographic profiles of ENS with age- and height-matched exclusive cigarette smokers (ECS). Methods Males aged 35-60 living in Sousse, Tunisia, who have been smoking narghile exclusively for more than 10 narghile-years (n = 36) or cigarettes exclusively for more than 10 pack-years (n = 106) were recruited to participate in this case-control study. The anthropometric and plethysmographic data were measured according to international recommendations using a body plethysmograph (ZAN 500 Body II, Meβgreräte GmbH, Germany). Large-airway-obstructive-ventilatory-defect (LAOVD) was defined as: first second forced expiratory volume/forced vital capacity (FEV 1 /FVC) below the lower-limit-of-normal (LLN). Restrictive-ventilatory-defect (RVD) was defined as total lung capacity < LLN. Lung hyperinflation was defined as residual volume > upper-limit-of-normal. Student t-test and χ 2 test were used to compare plethysmographic data and profiles of the two groups. Results The subjects in the ENS and ECS groups are well matched in age (45±7 vs. 47±5 years) and height (1.73±0.06 vs. 1.72±0.06 m) and used similar quantities of tobacco (36±22 narghile-years vs. 35±19 pack-years). Compared to the ENS group, the ECS group had significantly lower FEV 1 (84±12 vs. 60±21%), FVC (90±12 vs. 76±18%), and FEV 1 /FVC (99±7 vs. 83±17%). The two groups had similar percentages of RVD (31 vs. 36%), while the ECS group had a significantly higher percentage of LAOVD (8 vs. 58%) and lung hyperinflation (36 vs.57%). Conclusion Chronic exclusive narghile smoking has less adverse effects on pulmonary function tests than chronic exclusive cigarette smoking.

  7. Breast milk polyunsaturated fatty acids: associations with adolescent allergic disease and lung function.

    PubMed

    Waidyatillake, N T; Stoney, R; Thien, F; Lodge, C J; Simpson, J A; Allen, K J; Abramson, M J; Erbas, B; Svanes, C; Dharmage, S C; Lowe, A J

    2017-08-01

    It has been hypothesized that n-3 PUFA in breast milk may assist immune and lung development. There are very limited data on possible long-term effects on allergic disease and lung function. The aim was to investigate associations of n-3 and n-6 PUFA levels in colostrum and breast milk with allergic disease and lung function at ages 12 and 18 years. Polyunsaturated fatty acids were measured in 194 colostrum samples and in 118 three-month expressed breast milk samples from mothers of children enrolled in the Melbourne Atopy Cohort (MACS) Study, a high-risk birth cohort study. Associations with allergic diseases, skin prick tests and lung function assessed at 12 and 18 years were estimated using multivariable regression. Higher levels of n-3 but not n-6 PUFAs in colostrum were associated with a trend towards increased odds of allergic diseases, with strong associations observed for allergic rhinitis at 12 (OR = 5.69[95% CI: 1.83,17.60] per weight%) and 18 years (4.43[1.46,13.39]) and eczema at 18 years (9.89[1.44, 68.49]). Higher levels of colostrum n-3 PUFAs were associated with reduced sensitization (3.37[1.18, 9.6]), mean FEV 1 (-166 ml [-332, -1]) and FEV 1 /FVC ratio (-4.6%, [-8.1, -1.1]) at 12 years. Higher levels of colostrum n-3 PUFAs were associated with increased risks of allergic rhinitis and eczema up to 18 years, and sensitization and reduced lung function at 12 years. As residual confounding may have caused these associations, they should be replicated, but these results could indicate that strategies that increase maternal n-3 PUFA intake may not aid in allergic disease prevention. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Impact of direct substitution of arm span length for current standing height in elderly COPD.

    PubMed

    Pothirat, Chaicharn; Chaiwong, Warawut; Phetsuk, Nittaya

    2015-01-01

    Arm span length is related to standing height and has been studied as a substitute for current standing height for predicting lung function parameters. However, it has never been studied in elderly COPD patients. To evaluate the accuracy of substituting arm span length for current standing height in the evaluation of pulmonary function parameters and severity classification in elderly Thai COPD patients. Current standing height and arm span length were measured in COPD patients aged >60 years. Postbronchodilator spirometric parameters, forced vital capacity (FVC), forced expiratory volume in first second (FEV1), and ratio of FEV1/FVC (FEV1%), were used to classify disease severity according to global initiative for chronic obstructive lung disease criteria. Predicted values for each parameter were also calculated separately utilizing current standing height or arm span length measurements. Student's t-tests and chi-squared tests were used to compare differences between the groups. Statistical significance was set at P<0.05. A total of 106 COPD patients with a mean age of 72.1±7.8 years, mean body mass index of 20.6±3.8 kg/m(2), and mean standing height of 156.4±8.3 cm were enrolled. The mean arm span length exceeded mean standing height by 7.7±4.6 cm (164.0±9.0 vs 156.4±8.3 cm, P<0.001), at a ratio of 1.05±0.03. Percentages of both predicted FVC and FEV1 values based on arm span length were significantly lower than those using current standing height (76.6±25.4 vs 61.6±16.8, P<0.001 and 50.8±25.4 vs 41.1±15.3, P<0.001). Disease severity increased in 39.6% (42/106) of subjects using arm span length over current standing height for predicted lung function. Direct substitution of arm span length for current standing height in elderly Thai COPD patients should not be recommended in cases where arm span length exceeds standing height by more than 4 cm.

  9. The effect of inhaled corticosteroids on the development of emphysema in smokers assessed by annual computed tomography.

    PubMed

    Shaker, Saher B; Dirksen, Asger; Ulrik, Charlotte S; Hestad, Marianne; Stavngaard, Trine; Laursen, Lars C; Maltbaek, Niels; Clementsen, Paul; Skjaerbaek, Nanna; Nielsen, Lars; Stoel, Berend; Skovgaard, Lene T; Tonnesen, Philip

    2009-04-01

    The objective was to evaluate the effect of inhaled corticosteroids on disease progression in smokers with moderate to severe chronic obstructive pulmonary disease (COPD), as assessed by annual computed tomography (CT) using lung density (LD) measurements. Two hundred and fifty-four current smokers with COPD were randomised to treatment with either an inhaled corticosteroids (ICS), budesonide 400 microg bid, or placebo. COPD was defined as FEV(1) < or = 70% pred, FEV(1)/FVC < or = 60% and no reversibility to beta(2)-agonists and oral corticosteroids. The patients were followed for 2-4 years with biannual spirometry and annual CT and comprehensive lung function tests (LFT). CT images were analysed using Pulmo-CMS software. LD was derived from a pixel-density histogram of the whole lung as the 15th percentile density (PD15) and the relative area of emphysema at a threshold of -910 Hounsfield units (RA-910), and both were volume-adjusted to predicted total lung capacity. At baseline, mean age was 64 years and 64 years; mean number of pack-years was 56 and 56; mean FEV(1) was 1.53 L (51% pred) and 1.53 L (53% pred); mean PD15 was 103 g/L and 104 g/L; and mean RA-910 was 14% and 13%, respectively, for the budesonide and placebo groups. The annual fall in PD15 was -1.12 g/L in the budesonide group and -1.81 g/L in the placebo group (p = 0.09); the annual increase in RA-910 was 0.4% in the budesonide group and 1.1% in the placebo group (p = 0.02). There was no difference in annual decline in FEV(1) between ICS (-54 mL) and placebo (-56 mL) (p = 0.89). Long-term budesonide inhalation shows a non-significant trend towards reducing the progression of emphysema as determined by the CT-derived 15th percentile lung density from annual CT scans in current smokers with moderate to severe COPD.

  10. PHENOTYPIC AND GENETIC HETEROGENEITY AMONG SUBJECTS WITH MILD AIRFLOW OBSTRUCTION IN COPDGENE

    PubMed Central

    Lee, Jin Hwa; Cho, Michael H.; McDonald, Merry-Lynn N.; Hersh, Craig P.; Castaldi, Peter J.; Crapo, James D.; Wan, Emily S.; Dy, Jennifer G.; Chang, Yale; Regan, Elizabeth A.; Hardin, Megan; DeMeo, Dawn L.; Silverman, Edwin K.

    2014-01-01

    Background Chronic obstructive pulmonary disease (COPD) is characterized by marked phenotypic heterogeneity. Most previous studies have focused on COPD subjects with FEV1 < 80% predicted. We investigated the clinical and genetic heterogeneity in subjects with mild airflow limitation in spirometry grade 1 defined by the Global Initiative for chronic Obstructive Lung Disease (GOLD 1). Methods Data from current and former smokers participating in the COPDGene Study (NCT00608764) were analyzed. K-means clustering was performed to explore subtypes within 794 GOLD 1 subjects. For all subjects with GOLD 1 and with each cluster, a genome-wide association study and candidate gene testing were performed using smokers with normal lung function as a control group. Combinations of COPD genome-wide significant single nucleotide polymorphisms (SNPs) were tested for association with FEV1 (% predicted) in GOLD 1 and in a combined group of GOLD1 and smoking control subjects. Results K-means clustering of GOLD 1 subjects identified putative “near-normal”, “airway-predominant”, “emphysema-predominant” and “lowest FEV1 % predicted” subtypes. In non-Hispanic whites, the only SNP nominally associated with GOLD 1 status relative to smoking controls was rs7671167 (FAM13A) in logistic regression models with adjustment for age, sex, pack-years of smoking, and genetic ancestry. The emphysema-predominant GOLD 1 cluster was nominally associated with rs7671167 (FAM13A) and rs161976 (BICD1). The lowest FEV1 % predicted cluster was nominally associated with rs1980057 (HHIP) and rs1051730 (CHRNA3). Combinations of COPD genome-wide significant SNPs were associated with FEV1 (% predicted) in a combined group of GOLD 1 and smoking control subjects. Conclusions Our results indicate that GOLD 1 subjects show substantial clinical heterogeneity, which is at least partially related to genetic heterogeneity. PMID:25154699

  11. Phenotypic and genetic heterogeneity among subjects with mild airflow obstruction in COPDGene.

    PubMed

    Lee, Jin Hwa; Cho, Michael H; McDonald, Merry-Lynn N; Hersh, Craig P; Castaldi, Peter J; Crapo, James D; Wan, Emily S; Dy, Jennifer G; Chang, Yale; Regan, Elizabeth A; Hardin, Megan; DeMeo, Dawn L; Silverman, Edwin K

    2014-10-01

    Chronic obstructive pulmonary disease (COPD) is characterized by marked phenotypic heterogeneity. Most previous studies have focused on COPD subjects with FEV1 < 80% predicted. We investigated the clinical and genetic heterogeneity in subjects with mild airflow limitation in spirometry grade 1 defined by the Global Initiative for chronic Obstructive Lung Disease (GOLD 1). Data from current and former smokers participating in the COPDGene Study (NCT00608764) were analyzed. K-means clustering was performed to explore subtypes within 794 GOLD 1 subjects. For all subjects with GOLD 1 and with each cluster, a genome-wide association study and candidate gene testing were performed using smokers with normal lung function as a control group. Combinations of COPD genome-wide significant single nucleotide polymorphisms (SNPs) were tested for association with FEV1 (% predicted) in GOLD 1 and in a combined group of GOLD 1 and smoking control subjects. K-means clustering of GOLD 1 subjects identified putative "near-normal", "airway-predominant", "emphysema-predominant" and "lowest FEV1% predicted" subtypes. In non-Hispanic whites, the only SNP nominally associated with GOLD 1 status relative to smoking controls was rs7671167 (FAM13A) in logistic regression models with adjustment for age, sex, pack-years of smoking, and genetic ancestry. The emphysema-predominant GOLD 1 cluster was nominally associated with rs7671167 (FAM13A) and rs161976 (BICD1). The lowest FEV1% predicted cluster was nominally associated with rs1980057 (HHIP) and rs1051730 (CHRNA3). Combinations of COPD genome-wide significant SNPs were associated with FEV1 (% predicted) in a combined group of GOLD 1 and smoking control subjects. Our results indicate that GOLD 1 subjects show substantial clinical heterogeneity, which is at least partially related to genetic heterogeneity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Silicosis and lung function decrements among female ceramic workers in Italy.

    PubMed

    Forastiere, Francesco; Goldsmith, David F; Sperati, Alessandra; Rapiti, Elisabetta; Miceli, Maria; Cavariani, Fulvio; Perucci, Carlo A

    2002-11-01

    It is well known that male ceramic workers have elevated risks of chronic silicosis. The objective of this study was to assess whether female ceramic workers also have an increased risk of silicosis and whether these women have decreased lung function related to silica exposure. Ceramic workers from Civitacastellana, Italy, were enrolled in health surveillance during the 1970s. A total of 642 women were under surveillance; a respiratory monitoring program was conducted from 1974 to 1987, with follow-up through 1991 that included annual chest radiography and measurement of lung function. Radiography findings were defined as silicosis if the chest films were > or =1/0 with small, rounded opacities. Multiple linear regression models for repeated measures (generalized estimating equations) were run to evaluate associations of forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV(1)) with years of exposure and radiograph opacities. Nine cases of silicosis were identified on the basis of radiographic evidence. Silicosis risk was not associated with smoking but was related to employment before 1970 and demonstrated a dose-response gradient for years of exposure. FVC and FEV(1) both showed significant (p < 0.05) associations with duration of exposure and with positive radiography findings. The results for female ceramic workers are consistent with those for male employees regarding exposure to fibrogenic dusts.

  13. Pulmonary functions in tannery workers--a cross sectional study.

    PubMed

    Chandrasekaran, Vasanthi; Dilara, K; Padmavathi, R

    2014-01-01

    Tannery workers are at potential exposure to detrimental agents rendering them vulnerable to respiratory and dermal problems. Thus by performing pulmonary functions among leather tannery workers, we can decipher the effect of chromium and leather dust on lung functions and also the decline of respiratory functions with increasing years of exposure to leather dust. Pulmonary functions were assessed for 130 tannery workers and compared with the 130 unexposed office workers. Pulmonary function measurements namely FVC, FEV1, FEF25-75% and PEFR were measured using portable data logging Spirometer (KOKO Spirometer). The observed pulmonary functions of Tannery-workers in this study showed a reduction in FEV1, FVC, FEV1/FVC ratio, FEF25-75 and PEFR in relation to their predicted values and also compared to the unexposed. Smokers showed a decline in pulmonary functions compared to the non smokers because smoking acts as an additional risk factor in the development of respiratory illnesses. It is worthy to mention that the pulmonary function values correlate negatively with the duration of exposure to leather dust. So this study could provide base line information based upon which legal implementation of preventive measures could be undertaken.

  14. The outcome of pregnancies in women with cystic fibrosis--single centre experience 1998-2011.

    PubMed

    Thorpe-Beeston, J G; Madge, S; Gyi, K; Hodson, M; Bilton, D

    2013-02-01

    To describe the maternal and fetal outcomes of pregnancies in women with cystic fibrosis. Retrospective study. Single obstetric hospital and adult cystic fibrosis centre. Retrospective case-note review of pregnant women with cystic fibrosis referred for antenatal care and delivery. Maternal and fetal outcomes, mode of delivery, lung function and pregnancy complications. Forty-eight pregnancies were studied in 41 women. There were two miscarriages, 44 singleton pregnancies and two sets of twins. All babies were liveborn and survived. The mean gestational age at delivery was 35.9 ± 3.3 weeks. There were no fetal abnormalities or terminations of pregnancy. The median birthweight centile was 31.9 (interquartile range 14.9-55.6). Twenty-five (52.1%) of the women had pancreatic insufficiency and 17 (35.4%) required insulin. There was a positive correlation between booking predicted forced expiratory volume in 1 second (FEV(1) ) and gestational age at delivery (P < 0.01). Women with FEV(1) ≤60% were more likely to deliver earlier and by caesarean section compared with women with FEV(1) >60% (35.0 ± 3.2 weeks versus 37.1 ± 3.0 weeks; P = 0.02 and 75.0% versus 25.0%; P = 0.01). Three of the seven women with an FEV(1) <40% died within 18 months of delivery. Four of the eight women with FEV(1) 40-50% died between 2 and 8 years after delivery. Pregnancy for women with cystic fibrosis is possible and results in favourable maternal and fetal outcomes, but the incidence of preterm delivery and caesarean section is increased. Women with pre-existing poor lung function should be counselled antenatally to ensure that they understand the implications of their shortened life-expectancy and parenthood. © 2012 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2012 RCOG.

  15. Rolling Tobacco in Banana Leaves, Newspaper, or Copybook Paper Associated With Significant Reduction in Lung Function in Vanuatu.

    PubMed

    Weitz, Charles A; Olszowy, Kathryn M; Dancause, Kelsey N; Sun, Cheng; Pomer, Alysa; Silverman, Howard; Lee, G; Tarivonda, Len; Chan, Chim W; Kaneko, Akira; Lum, J K; Garruto, Ralph M

    2017-04-01

    In addition to the widespread availability of packaged cigarettes, the inhabitants of island nations of the Southwest Pacific frequently smoke commercially available loose tobacco using manufactured rolling papers, as well as locally grown tobacco rolled in manufactured rolling paper or wrapped in leaves, copybook paper, and newspaper. In this study, Vanuatu men who smoked local tobacco rolled in leaves, copybook paper, or newspaper showed significantly lower forced vital capacity (FVC), forced expiratory volume in 1 second (FEV 1 ), and FEV 1 /FVC ratios than men who smoked packaged cigarettes, store-bought tobacco rolled in manufactured rolling paper, or who smoked locally grown tobacco rolled in manufactured rolling papers. The addition of toxins from these unusual tobacco-wrapping media produces lung function deficits similar to the pattern noted among tobacco smokers who also inhale smoke from burning biomass. Thus, public health initiatives should consider including strategies addressing the use of wrapping media among smokers in South Pacific island societies.

  16. Consequences of Expiratory Flow Limitation at Rest in Subjects with Cystic Fibrosis.

    PubMed

    Vilozni, Daphna; Lavie, Moran; Ofek, Miryam; Sarouk, Ifat; Bar-Aluma, Bat-El; Dagan, Adi; Ashkenazi, Moshe; Segel, Michael J; Efrati, Ori

    2016-06-01

    Expiratory flow limitation at resting tidal volume (EFLTV) presents a severe mechanical constraint in chronic lung diseases and has not yet been studied longitudinally in cystic fibrosis. To study the effect of EFLTV as it emerged from simple spirometry on lung function and clinical status in cystic fibrosis. Best year spirometry that included tidal flow/volume curves and the related clinical data were retrospectively collected over 12 ± 3.0 yr/person from 108 subjects with cystic fibrosis. The year in which forced expiratory flow, midexpiratory phase (FEF25-75%, L/s) was equal to tidal peak expiratory flow (L/s) was defined as EFLTV-onset year. EFLTV occurred in 55 (51%) subjects, at age 23 ± 6 years. At EFLTV onset, tidal peak expiratory flow and FEF25-75% values were 1.44 ± 0.23 L/s and FEV1 was 62 ± 10% predicted. Within the following 2 years, FEV1 dropped to 48 ± 11% predicted, and 35 (63%) of the subjects reported shortness of breath at rest. Hospital days increased from 5.3 ± 24.6 to 24.12 ± 9.0 d/yr (P = 0.0001). Of the 55 subjects, 29 (53%) received transplant or died, with survival time being 6.9 ± 3.9 years. EFLTV onset may be an important pathophysiological event that could influence the natural history of lung function decline in subjects with cystic fibrosis. This may lead to a significant deterioration in lung function in the following 2 years alongside an increase in the number of hospitalization days. The monitoring of FEV1 alone does not offer as good a threshold signal, because values are only moderately reduced. Therefore, identifying EFLTV appearance is potentially a signal for therapeutic intervention. Further studies are warranted to confirm our findings.

  17. IL6R Variation Asp358Ala Is a Potential Modifier of Lung Function in Asthma

    PubMed Central

    Hawkins, Gregory A; Robinson, Mac B; Hastie, Annette T; Li, Xingnan; Li, Huashi; Moore, Wendy C; Howard, Timothy D; Busse, William W.; Erzurum, Serpil C.; Wenzel, Sally E.; Peters, Stephen P; Meyers, Deborah A; Bleecker, Eugene R

    2012-01-01

    Background The IL6R SNP rs4129267 has recently been identified as an asthma susceptibility locus in subjects of European ancestry but has not been characterized with respect to asthma severity. The SNP rs4129267 is in linkage disequilibrium (r2=1) with the IL6R coding SNP rs2228145 (Asp358Ala). This IL6R coding change increases IL6 receptor shedding and promotes IL6 transsignaling. Objectives To evaluate the IL6R SNP rs2228145 with respect to asthma severity phenotypes. Methods The IL6R SNP rs2228145 was evaluated in subjects of European ancestry with asthma from the Severe Asthma Research Program (SARP). Lung function associations were replicated in the Collaborative Study on the Genetics of Asthma (CSGA) cohort. Serum soluble IL6 receptor (sIL6R) levels were measured in subjects from SARP. Immunohistochemistry was used to qualitatively evaluate IL6R protein expression in BAL cells and endobronchial biopsies. Results The minor C allele of IL6R SNP rs2228145 was associated with lower ppFEV1 in the SARP cohort (p=0.005), the CSGA cohort (0.008), and in combined cohort analysis (p=0.003). Additional associations with ppFVC, FEV1/FVC, and PC20 were observed. The rs2228145 C allele (Ala358) was more frequent in severe asthma phenotypic clusters. Elevated serum sIL6R was associated with lower ppFEV1 (p=0.02) and lower ppFVC (p=0.008) (N=146). IL6R protein expression was observed in BAL macrophages, airway epithelium, vascular endothelium, and airway smooth muscle. Conclusions The IL6R coding SNP rs2228145 (Asp358Ala) is a potential modifier of lung function in asthma and may identify subjects at risk for more severe asthma. IL6 transsignaling may have a pathogenic role in the lung. PMID:22554704

  18. Occupation and three-year incidence of respiratory symptoms and lung function decline: the ARIC Study.

    PubMed

    Mirabelli, Maria C; London, Stephanie J; Charles, Luenda E; Pompeii, Lisa A; Wagenknecht, Lynne E

    2012-03-20

    Specific occupations are associated with adverse respiratory health. Inhalation exposures encountered in these jobs may place workers at risk of new-onset respiratory disease. We analyzed data from 8,967 participants from the Atherosclerosis Risk in Communities (ARIC) study, a longitudinal cohort study. Participants included in this analysis were free of chronic cough and phlegm, wheezing, asthma, chronic bronchitis, emphysema, and other chronic lung conditions at the baseline examination, when they were aged 45-64 years. Using data collected in the baseline and first follow-up examination, we evaluated associations between occupation and the three-year incidence of cough, phlegm, wheezing, and airway obstruction and changes in forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) measured by spirometry. All associations were adjusted for age, cigarettes per day, race, smoking status, and study center. During the approximately three-year follow-up, the percentage of participants developing chronic cough was 3%; chronic phlegm, 3%; wheezing, 3%; and airway obstruction, defined as FEV1 < lower limit of normal (LLN) and FEV1/FVC < LLN, 2%. The average annual declines in FEV1 and FVC were 56 mL and 66 mL, respectively, among men and 40 mL and 52 mL, respectively, among women. Relative to a referent category of managerial and administrative support occupations, elevated risks of new-onset chronic cough and chronic phlegm were observed for mechanics and repairers (chronic cough: RR: 1.81, 95% CI: 1.02, 3.21; chronic phlegm: RR: 2.10, 95% CI: 1.23, 3.57) and cleaning and building service workers (chronic cough: RR: 1.85, 95% CI: 1.01, 3.37; chronic phlegm: RR: 2.28, 95% CI: 1.27, 4.08). Despite the elevated risk of new-onset symptoms, employment in cleaning and building services was associated with attenuated lung function decline, particularly among men, who averaged annual declines in FEV1 and FVC of 14 mL and 23 mL, respectively, less than the declines observed in the referent population. Employment in mechanic and repair jobs and cleaning and building service occupations are associated with increased incidence of respiratory symptoms. Specific occupations affect the respiratory health of adults without pre-existing respiratory health symptoms and conditions, though long-term health consequences of inhalation exposures in these jobs remain largely unexplored.

  19. Occupation and three-year incidence of respiratory symptoms and lung function decline: the ARIC Study

    PubMed Central

    2012-01-01

    Background Specific occupations are associated with adverse respiratory health. Inhalation exposures encountered in these jobs may place workers at risk of new-onset respiratory disease. Methods We analyzed data from 8,967 participants from the Atherosclerosis Risk in Communities (ARIC) study, a longitudinal cohort study. Participants included in this analysis were free of chronic cough and phlegm, wheezing, asthma, chronic bronchitis, emphysema, and other chronic lung conditions at the baseline examination, when they were aged 45-64 years. Using data collected in the baseline and first follow-up examination, we evaluated associations between occupation and the three-year incidence of cough, phlegm, wheezing, and airway obstruction and changes in forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) measured by spirometry. All associations were adjusted for age, cigarettes per day, race, smoking status, and study center. Results During the approximately three-year follow-up, the percentage of participants developing chronic cough was 3%; chronic phlegm, 3%; wheezing, 3%; and airway obstruction, defined as FEV1 < lower limit of normal (LLN) and FEV1/FVC < LLN, 2%. The average annual declines in FEV1 and FVC were 56 mL and 66 mL, respectively, among men and 40 mL and 52 mL, respectively, among women. Relative to a referent category of managerial and administrative support occupations, elevated risks of new-onset chronic cough and chronic phlegm were observed for mechanics and repairers (chronic cough: RR: 1.81, 95% CI: 1.02, 3.21; chronic phlegm: RR: 2.10, 95% CI: 1.23, 3.57) and cleaning and building service workers (chronic cough: RR: 1.85, 95% CI: 1.01, 3.37; chronic phlegm: RR: 2.28, 95% CI: 1.27, 4.08). Despite the elevated risk of new-onset symptoms, employment in cleaning and building services was associated with attenuated lung function decline, particularly among men, who averaged annual declines in FEV1 and FVC of 14 mL and 23 mL, respectively, less than the declines observed in the referent population. Conclusions Employment in mechanic and repair jobs and cleaning and building service occupations are associated with increased incidence of respiratory symptoms. Specific occupations affect the respiratory health of adults without pre-existing respiratory health symptoms and conditions, though long-term health consequences of inhalation exposures in these jobs remain largely unexplored. PMID:22433119

  20. Predictive Value of Different Expressions of Forced Expiratory Volume in 1 Second (FEV1) for Adverse Outcomes in a Cohort of Adults Aged 80 and Older.

    PubMed

    Hegendörfer, Eralda; Vaes, Bert; Andreeva, Elena; Matheï, Catharina; Van Pottelbergh, Gijs; Degryse, Jean-Marie

    2017-02-01

    Forced expiratory volume in 1 second (FEV 1 ) is proposed as a marker of healthy ageing and FEV 1 expressions that are independent of reference values have been reported to be better at predicting mortality in older adults. We assess and compare the predictive value of different FEV 1 expressions for mortality, hospitalization, and physical and mental decline in adults aged 80 and older. Population-based, prospective, cohort study. The BELFRAIL study, Belgium. A total of 501 community-dwelling adults aged 80 and older (mean age 84.7 years). Baseline FEV 1 expressed as percent predicted (FEV 1 PP) and z-score (FEV 1 Z) using the Global Lung Function Initiative 2012 reference values; over lowest sex-specific percentile (FEV 1 Q), and height squared (FEV 1 /Ht 2 ) and cubed (FEV 1 /Ht 3 ). Mortality data until 5.1 ± 0.2 years from baseline; hospitalization data until 3.0 ± 0.25 years. Activities of daily living, battery of physical performance tests, Mini-Mental State Examination, and 15-item Geriatric Depression Scale at baseline and after 1.7 ± 0.2 years. Individuals in the lowest quartile of FEV 1 expressions had higher adjusted risk than the rest of study population for all-cause mortality (highest hazard ratio 2.05 [95% Confidence Interval 1.50-2.80] for FEV 1 Q and 2.01 [1.47-2.76] for FEV 1 /Ht 3 ), first hospitalization (highest hazard ratio 1.63 [1.21-2.16] for FEV 1 /Ht 2 and 1.61[1.20-2.16] for FEV 1 /Ht 3 ), mental decline (highest odds ratio 2.80 [1.61-4.89] for FEV 1 Q) and physical decline (only FEV 1 /Ht 3 with odds ratio 1.93 [1.13-3.30]). Based on risk classification improvement measures, FEV 1 /Ht 3 and FEV 1 Q performed better than FEV 1 PP. In a cohort of adults aged 80 and older, FEV 1 expressions that are independent of reference values (FEV 1 /Ht 3 and FEV 1 Q) were better at predicting adverse health outcomes than traditional expressions that depend on reference values, and should be used in further research on FEV 1 and aging. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  1. Investigation of Hydrogen Sulfide Exposure and Lung Function, Asthma and Chronic Obstructive Pulmonary Disease in a Geothermal Area of New Zealand

    PubMed Central

    Bates, Michael N.; Crane, Julian; Balmes, John R.; Garrett, Nick

    2015-01-01

    Background Results have been conflicting whether long-term ambient hydrogen sulfide (H2S) affects lung function or is a risk factor for asthma or chronic obstructive pulmonary disease (COPD). Rotorua city, New Zealand, has the world’s largest population exposed to ambient H2S—from geothermal sources. Objectives We investigated associations of H2S with lung function, COPD and asthma in this population. Methods 1,204 of 1,639 study participants, aged 18–65 years during 2008–2010, provided satisfactory spirometry results. Residences, workplaces and schools over the last 30 years were geocoded. Exposures were estimated from data collected by summer and winter H2S monitoring networks across Rotorua. Four metrics for H2S exposure, representing both current and long-term (last 30 years) exposure, and also time-weighted average and peak exposures, were calculated. Departures from expected values for pre-bronchodilator lung function, calculated from prediction equations, were outcomes for linear regression models using quartiles of the H2S exposure metrics. Separate models examined participants with and without evidence of asthma or COPD, and never- and ever-smokers. Logistic regression was used to investigate associations of COPD (a post-bronchodilator FEV1/FVC < 70% of expected) and asthma (doctor-diagnosed or by FEV1 response to bronchodilator) with H2S exposure quartiles. Results None of the exposure metrics produced evidence of lung function decrement. The logistic regression analysis showed no evidence that long-term H2S exposure at Rotorua levels was associated with either increased COPD or asthma risk. Some results suggested that recent ambient H2S exposures were beneficially associated with lung function parameters. Conclusions The study found no evidence of reductions in lung function, or increased risk of COPD or asthma, from recent or long-term H2S exposure at the relatively high ambient concentrations found in Rotorua. Suggestions of improved lung function associated with recent ambient H2S exposures require confirmation in other studies. PMID:25822819

  2. Investigation of hydrogen sulfide exposure and lung function, asthma and chronic obstructive pulmonary disease in a geothermal area of New Zealand.

    PubMed

    Bates, Michael N; Crane, Julian; Balmes, John R; Garrett, Nick

    2015-01-01

    Results have been conflicting whether long-term ambient hydrogen sulfide (H2S) affects lung function or is a risk factor for asthma or chronic obstructive pulmonary disease (COPD). Rotorua city, New Zealand, has the world's largest population exposed to ambient H2S-from geothermal sources. We investigated associations of H2S with lung function, COPD and asthma in this population. 1,204 of 1,639 study participants, aged 18-65 years during 2008-2010, provided satisfactory spirometry results. Residences, workplaces and schools over the last 30 years were geocoded. Exposures were estimated from data collected by summer and winter H2S monitoring networks across Rotorua. Four metrics for H2S exposure, representing both current and long-term (last 30 years) exposure, and also time-weighted average and peak exposures, were calculated. Departures from expected values for pre-bronchodilator lung function, calculated from prediction equations, were outcomes for linear regression models using quartiles of the H2S exposure metrics. Separate models examined participants with and without evidence of asthma or COPD, and never- and ever-smokers. Logistic regression was used to investigate associations of COPD (a post-bronchodilator FEV1/FVC < 70% of expected) and asthma (doctor-diagnosed or by FEV1 response to bronchodilator) with H2S exposure quartiles. None of the exposure metrics produced evidence of lung function decrement. The logistic regression analysis showed no evidence that long-term H2S exposure at Rotorua levels was associated with either increased COPD or asthma risk. Some results suggested that recent ambient H2S exposures were beneficially associated with lung function parameters. The study found no evidence of reductions in lung function, or increased risk of COPD or asthma, from recent or long-term H2S exposure at the relatively high ambient concentrations found in Rotorua. Suggestions of improved lung function associated with recent ambient H2S exposures require confirmation in other studies.

  3. Effects of Autogenic Drainage on Sputum Recovery and Pulmonary Function in People with Cystic Fibrosis: A Systematic Review.

    PubMed

    Morgan, Kimbly; Osterling, Kristin; Gilbert, Robert; Dechman, Gail

    2015-01-01

    To determine the effects of short- and long-term use of autogenic drainage (AD) on pulmonary function and sputum recovery in people with cystic fibrosis (CF). The authors conducted a systematic review of randomized and quasi-randomized clinical trials in which participants were people with CF who use AD as their sole airway clearance technique. Searches in 4 databases and secondary sources using 5 key terms yielded 735 articles, of which 58 contained the terms autogenic drainage and cystic fibrosis. Ultimately, 4 studies, 2 of which were long term, were included. All measured forced expiratory volume in 1 second (FEV1) and found no change. The long-term studies were underpowered to detect change in FEV1; however, the short-term studies found a clinically significant sputum yield (≥4 g). AD has been shown to produce clinically significant sputum yields in a limited number of investigations. The effect of AD on the function of the pulmonary system remains uncertain, and questions have emerged regarding the appropriateness of FEV1 as a valid measure of airway clearance from peripheral lung regions. Further consideration should be given to the use of FEV1 as a primary measure of the effect of AD.

  4. Effects of Autogenic Drainage on Sputum Recovery and Pulmonary Function in People with Cystic Fibrosis: A Systematic Review

    PubMed Central

    Osterling, Kristin; Gilbert, Robert; Dechman, Gail

    2015-01-01

    ABSTRACT Purpose: To determine the effects of short- and long-term use of autogenic drainage (AD) on pulmonary function and sputum recovery in people with cystic fibrosis (CF). Methods: The authors conducted a systematic review of randomized and quasi-randomized clinical trials in which participants were people with CF who use AD as their sole airway clearance technique. Results: Searches in 4 databases and secondary sources using 5 key terms yielded 735 articles, of which 58 contained the terms autogenic drainage and cystic fibrosis. Ultimately, 4 studies, 2 of which were long term, were included. All measured forced expiratory volume in 1 second (FEV1) and found no change. The long-term studies were underpowered to detect change in FEV1; however, the short-term studies found a clinically significant sputum yield (≥4 g). Conclusion: AD has been shown to produce clinically significant sputum yields in a limited number of investigations. The effect of AD on the function of the pulmonary system remains uncertain, and questions have emerged regarding the appropriateness of FEV1 as a valid measure of airway clearance from peripheral lung regions. Further consideration should be given to the use of FEV1 as a primary measure of the effect of AD. PMID:27504031

  5. Tobacco Use and Its Health Effects among Professional Athletes in Qatar

    PubMed Central

    Chaabane, Zaina; Mahfoud, Ziyad

    2016-01-01

    The objective of the study was to determine the effects of tobacco use on selected markers of health and lung function in professional athletes. A total of 108 male professional athletes participated in the study from ten ball game teams in the same sport league in Qatar (age = 26.4 ± 5.1 yrs, height = 190.6 ± 11.9 cm, and weight = 91.5 ± 16.4 kg). The athletes have been playing professionally for about 6.3 years on average. In addition to demographic and tobacco use status, the following clinical variables were measured: resting blood pressure, heart rate, FVC, FEV1 sec, and PEF. The prevalence of tobacco use among the athletes was 27.7%. The FVC, FVC%, and FEV1% were significantly lower among the smokers compared to the nonsmokers (p = 0.003, 0.044, and 0.001, resp.). There were no significant differences between cigarettes smokers and nonsmokers in BP, HR, FEV1, FEV1/FVC, PEF, and PEF%. Similarly, those who smoked shisha had lower FEV1% values as compared to those who did not smoke shisha (p = 0.001). The decrease of FEV1 and FVC among smokers compared to nonsmokers is similar to what has been reported in the literature about other populations. PMID:28025593

  6. Congruence Between Pulmonary Function and Computed Tomography Imaging Assessment of Cystic Fibrosis Severity.

    PubMed

    Rybacka, Anna; Goździk-Spychalska, Joanna; Rybacki, Adam; Piorunek, Tomasz; Batura-Gabryel, Halina; Karmelita-Katulska, Katarzyna

    2018-05-04

    In cystic fibrosis, pulmonary function tests (PFTs) and computed tomography are used to assess lung function and structure, respectively. Although both techniques of assessment are congruent there are lingering doubts about which PFTs variables show the best congruence with computed tomography scoring. In this study we addressed the issue by reinvestigating the association between PFTs variables and the score of changes seen in computed tomography scans in patients with cystic fibrosis with and without pulmonary exacerbation. This retrospective study comprised 40 patients in whom PFTs and computed tomography were performed no longer than 3 weeks apart. Images (inspiratory: 0.625 mm slice thickness, 0.625 mm interval; expiratory: 1.250 mm slice thickness, 10 mm interval) were evaluated with the Bhalla scoring system. The most frequent structural abnormality found in scans were bronchiectases and peribronchial thickening. The strongest relationship was found between the Bhalla sore and forced expiratory volume in 1 s (FEV1). The Bhalla sore also was related to forced vital capacity (FVC), FEV1/FVC ratio, residual volume (RV), and RV/total lung capacity (TLC) ratio. We conclude that lung structural data obtained from the computed tomography examination are highly congruent to lung function data. Thus, computed tomography imaging may supersede functional assessment in cases of poor compliance with spirometry procedures in the lederly or children. Computed tomography also seems more sensitive than PFTs in the assessment of cystic fibrosis progression. Moreover, in early phases of cystic fibrosis, computed tomography, due to its excellent resolution, may be irreplaceable in monitoring pulmonary damage.

  7. The role of traffic noise on the association between air pollution and children's lung function.

    PubMed

    Franklin, Meredith; Fruin, Scott

    2017-08-01

    Although it has been shown that traffic-related air pollution adversely affects children's lung function, few studies have examined the influence of traffic noise on this association, despite both sharing a common source. Estimates of noise exposure (L dn, dB), and freeway and non-freeway emission concentrations of oxides of nitrogen (NO x , ppb) were spatially assigned to children in Southern California who were tested for forced vital capacity (FVC, n=1345), forced expiratory volume in 1s, (FEV 1, n=1332), and asthma. The associations between traffic-related NO x and these outcomes, with and without adjustment for noise, were examined using mixed effects models. Adjustment for noise strengthened the association between NO x and reduced lung function. A 14.5mL (95% CI -40.0, 11.0mL) decrease in FVC per interquartile range (13.6 ppb) in freeway NO x was strengthened to a 34.6mL decrease after including a non-linear function of noise (95% CI -66.3, -2.78mL). Similarly, a 6.54mL decrease in FEV 1 (95% CI -28.3, 15.3mL) was strengthened to a 21.1mL decrease (95% CI -47.6, 5.51) per interquartile range in freeway NO x . Our results indicate that where possible, noise should be included in epidemiological studies of the association between traffic-related air pollution on lung function. Without taking noise into account, the detrimental effects of traffic-related pollution may be underestimated. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Physical activity is not associated with spirometric indices in lung-healthy German youth.

    PubMed

    Smith, Maia P; von Berg, Andrea; Berdel, Dietrich; Bauer, Carl-Peter; Hoffmann, Barbara; Koletzko, Sibylle; Nowak, Dennis; Heinrich, Joachim; Schulz, Holger

    2016-08-01

    In lung disease, physical activity improves lung function and reduces morbidity. However, healthy populations are not well studied. We estimate the relationship between spirometric indices and accelerometric physical activity in lung-healthy adolescents.895 nonsmoking German adolescents without chronic lung disease (45% male, mean±sd age 15.2±0.26 years) from the GINIplus and LISAplus cohorts completed questionnaires, spirometry, 7-day accelerometry and an activity diary. Physical activity was measured as minutes, quintiles and regularity of daily moderate, vigorous and moderate-to-vigorous physical activity (MVPA), participation in sport and active commuting to school. Primary outcomes were forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC and forced expiratory flow at 25-75% of FVC; they were separately correlated with physical activity and adjusted for confounders of respiratory function, including early-life exposures.Adolescents averaged 40 min MVPA per day, typical for European youth. 79% participated in sports and 51% commuted actively. An association was suggested between 3% higher FVC (∼100 mL) and either extreme MVPA quintile or percentage of days with >30 min MVPA (p<0.05). However, after Bonferroni correction all associations between spirometry, active lifestyle and physical activity were nonsignificant.Spirometric indices were not significantly associated with active lifestyle or measures of activity in lung-healthy adolescents after adjustment for confounding and multiple-comparison artefacts. Copyright ©ERS 2016.

  9. Lung volumes and maximal respiratory pressures in collegiate swimmers and runners.

    PubMed

    Cordain, L; Tucker, A; Moon, D; Stager, J M

    1990-03-01

    To determine whether respiratory muscle strength is related to pulmonary volume differences in athletes and nonathletes, 11 intercollegiate female swimmers, 11 female cross-country runners, and two nonathletic control groups, matched to the athletes in height and age, were evaluated for pulmonary parameters including maximal inspiratory pressure (PImax) and maximal expiratory pressure (PEmax). Swimmers exhibited larger (p less than .05) vital capacities (VC), residual lung volumes (RV), inspiratory capacities (IC), and functional residual capacities (FRC) than both the runners or the controls but no difference (p greater than .05) in either PImax or inspiratory flow (FIV 25%-75%). Timed expiratory volumes (FEV 0.5 and FEV 1.0) were significantly (p less than .05) lower in the swimmers than in the controls. These data suggest that an adaptational growth may be responsible, in part, for the augmented static lung volumes demonstrated in swimmers.

  10. Characteristics and self-rated health of overlap syndrome.

    PubMed

    Chung, Jung Wha; Kong, Kyoung Ae; Lee, Jin Hwa; Lee, Seok Jeong; Ryu, Yon Ju; Chang, Jung Hyun

    2014-01-01

    Overlap syndrome shares features of both asthma and chronic obstructive pulmonary disease (COPD). The aim of this study was to investigate characteristics of overlap syndrome and their effect on self-rated health (SRH). We analyzed data from the Fourth Korea National Health and Nutrition Examination Survey of 2007-2009. Subjects with acceptable spirometry and available wheezing history were included. Subjects were classified into four groups based on forced expiratory volume in one second (FEV1)/forced vital capacity (FVC) results and the presence or absence of self-reported wheezing for the previous 12 months: 1) COPD group, defined as having FEV1/FVC <0.7 without self-reported wheezing history; 2) asthma group, defined as having self-reported wheezing history without FEV1/FVC <0.7; 3) overlap syndrome group, having both FEV1/FVC <0.7 and wheezing history; and 4) non-obstructive disease (NOD) group, having neither FEV1/FVC <0.7 nor self-reported wheezing. SRH was categorized as better or lower based on responses to a questionnaire. From a total 9,104 subjects, 700 were assigned to the COPD group, 560 to the asthma group, 210 to the overlap syndrome group, and 7,634 to the NOD group. Compared to the other groups, subjects in the overlap syndrome group were more likely to have low lung function, a high proportion of smokers, low socioeconomic status, short education duration, lower SRH, and past diagnosis of pulmonary tuberculosis or bronchiectasis. Multiple logistic regression analysis revealed that both overlap syndrome and asthma groups were independently associated with lower SRH after adjustment for age, sex, socioeconomic status, education level, smoking status, comorbidities, and lung function. Female, old age, low education level, low economic status, smoker and other comorbidities were also associated with lower SRH. Overlap syndrome was accompanied by high morbidity and was associated with lower SRH, which needs more appropriate care.

  11. Early Elevation of Serum MMP-3 and MMP-12 Predicts Protection from World Trade Center-Lung Injury in New York City Firefighters: A Nested Case-Control Study

    PubMed Central

    Echevarria, Ghislaine C.; Comfort, Ashley L.; Naveed, Bushra; Prezant, David J.; Rom, William N.; Nolan, Anna

    2013-01-01

    Objective After 9/11/2001, some Fire Department of New York (FDNY) workers had excessive lung function decline. We hypothesized that early serum matrix metalloproteinases (MMP) expression predicts World Trade Center-Lung Injury (WTC-LI) years later. Methods This is a nested case-control analysis of never-smoking male firefighters with normal pre-exposure Forced Expiratory Volume in one second (FEV1) who had serum drawn up to 155 days post 9/11/2001. Serum MMP-1, 2,3,7,8, 9, 12 and 13 were measured. Cases of WTC-LI (N = 70) were defined as having an FEV1 one standard deviation below the mean (FEV1≤77%) at subspecialty pulmonary evaluation (SPE) which was performed 32 months (IQR 21–53) post-9/11. Controls (N = 123) were randomly selected. We modeled MMP's ability as a predictor of cases status with logistic regression adjusted for time to blood draw, exposure intensity, weight gain and pre-9/11 FEV1. Results Each log-increase in MMP-3 and MMP-12 showed reduced odds of developing WTC-LI by 73% and 54% respectively. MMP-3 and MMP-12 consistently clustered together in cases, controls, and the cohort. Increasing time to blood draw significantly and independently increased the risk of WTC-LI. Conclusions Elevated serum levels of MMP-3 and MMP-12 reduce the risk of developing WTC-LI. At any level of MMP-3 or 12, increased time to blood draw is associated with a diminished protective effect. PMID:24146820

  12. Evaluation of pulmonary function using single-breath-hold dual-energy computed tomography with xenon

    PubMed Central

    Kyoyama, Hiroyuki; Hirata, Yusuke; Kikuchi, Satoshi; Sakai, Kosuke; Saito, Yuriko; Mikami, Shintaro; Moriyama, Gaku; Yanagita, Hisami; Watanabe, Wataru; Otani, Katharina; Honda, Norinari; Uematsu, Kazutsugu

    2017-01-01

    Abstract Xenon-enhanced dual-energy computed tomography (xenon-enhanced CT) can provide lung ventilation maps that may be useful for assessing structural and functional abnormalities of the lung. Xenon-enhanced CT has been performed using a multiple-breath-hold technique during xenon washout. We recently developed xenon-enhanced CT using a single-breath-hold technique to assess ventilation. We sought to evaluate whether xenon-enhanced CT using a single-breath-hold technique correlates with pulmonary function testing (PFT) results. Twenty-six patients, including 11 chronic obstructive pulmonary disease (COPD) patients, underwent xenon-enhanced CT and PFT. Three of the COPD patients underwent xenon-enhanced CT before and after bronchodilator treatment. Images from xenon-CT were obtained by dual-source CT during a breath-hold after a single vital-capacity inspiration of a xenon–oxygen gas mixture. Image postprocessing by 3-material decomposition generated conventional CT and xenon-enhanced images. Low-attenuation areas on xenon images matched low-attenuation areas on conventional CT in 21 cases but matched normal-attenuation areas in 5 cases. Volumes of Hounsfield unit (HU) histograms of xenon images correlated moderately and highly with vital capacity (VC) and total lung capacity (TLC), respectively (r = 0.68 and 0.85). Means and modes of histograms weakly correlated with VC (r = 0.39 and 0.38), moderately with forced expiratory volume in 1 second (FEV1) (r = 0.59 and 0.56), weakly with the ratio of FEV1 to FVC (r = 0.46 and 0.42), and moderately with the ratio of FEV1 to its predicted value (r = 0.64 and 0.60). Mode and volume of histograms increased in 2 COPD patients after the improvement of FEV1 with bronchodilators. Inhalation of xenon gas caused no adverse effects. Xenon-enhanced CT using a single-breath-hold technique depicted functional abnormalities not detectable on thin-slice CT. Mode, mean, and volume of HU histograms of xenon images reflected pulmonary function. Xenon images obtained with xenon-enhanced CT using a single-breath-hold technique can qualitatively depict pulmonary ventilation. A larger study comprising only COPD patients should be conducted, as xenon-enhanced CT is expected to be a promising technique for the management of COPD. PMID:28099359

  13. Evaluation of pulmonary function using single-breath-hold dual-energy computed tomography with xenon: Results of a preliminary study.

    PubMed

    Kyoyama, Hiroyuki; Hirata, Yusuke; Kikuchi, Satoshi; Sakai, Kosuke; Saito, Yuriko; Mikami, Shintaro; Moriyama, Gaku; Yanagita, Hisami; Watanabe, Wataru; Otani, Katharina; Honda, Norinari; Uematsu, Kazutsugu

    2017-01-01

    Xenon-enhanced dual-energy computed tomography (xenon-enhanced CT) can provide lung ventilation maps that may be useful for assessing structural and functional abnormalities of the lung. Xenon-enhanced CT has been performed using a multiple-breath-hold technique during xenon washout. We recently developed xenon-enhanced CT using a single-breath-hold technique to assess ventilation. We sought to evaluate whether xenon-enhanced CT using a single-breath-hold technique correlates with pulmonary function testing (PFT) results.Twenty-six patients, including 11 chronic obstructive pulmonary disease (COPD) patients, underwent xenon-enhanced CT and PFT. Three of the COPD patients underwent xenon-enhanced CT before and after bronchodilator treatment. Images from xenon-CT were obtained by dual-source CT during a breath-hold after a single vital-capacity inspiration of a xenon-oxygen gas mixture. Image postprocessing by 3-material decomposition generated conventional CT and xenon-enhanced images.Low-attenuation areas on xenon images matched low-attenuation areas on conventional CT in 21 cases but matched normal-attenuation areas in 5 cases. Volumes of Hounsfield unit (HU) histograms of xenon images correlated moderately and highly with vital capacity (VC) and total lung capacity (TLC), respectively (r = 0.68 and 0.85). Means and modes of histograms weakly correlated with VC (r = 0.39 and 0.38), moderately with forced expiratory volume in 1 second (FEV1) (r = 0.59 and 0.56), weakly with the ratio of FEV1 to FVC (r = 0.46 and 0.42), and moderately with the ratio of FEV1 to its predicted value (r = 0.64 and 0.60). Mode and volume of histograms increased in 2 COPD patients after the improvement of FEV1 with bronchodilators. Inhalation of xenon gas caused no adverse effects.Xenon-enhanced CT using a single-breath-hold technique depicted functional abnormalities not detectable on thin-slice CT. Mode, mean, and volume of HU histograms of xenon images reflected pulmonary function. Xenon images obtained with xenon-enhanced CT using a single-breath-hold technique can qualitatively depict pulmonary ventilation. A larger study comprising only COPD patients should be conducted, as xenon-enhanced CT is expected to be a promising technique for the management of COPD.

  14. Factors Associated With Early Mortality in Patients Treated With Concurrent Chemoradiation Therapy for Locally Advanced Non-Small Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warner, Andrew; Dahele, Max; Hu, Bo

    Purpose: Concurrent chemoradiation therapy (con-CRT) is recommended for fit patients with locally advanced non-small cell lung cancer (LA-NSCLC) but is associated with toxicity, and observed survival continues to be limited. Identifying factors associated with early mortality could improve patient selection and identify strategies to improve prognosis. Methods and Materials: Analysis of a multi-institutional LA-NSCLC database consisting of 1245 patients treated with con-CRT in 13 institutions was performed to identify factors predictive of 180-day survival. Recursive partitioning analysis (RPA) was performed to identify prognostic groups for 180-day survival. Multivariate logistic regression analysis was used to create a clinical nomogram predicting 180-daymore » survival based on important predictors from RPA. Results: Median follow-up was 43.5 months (95% confidence interval [CI]: 40.3-48.8) and 127 patients (10%) died within 180 days of treatment. Median, 180-day, and 1- to 5-year (by yearly increments) actuarial survival rates were 20.9 months, 90%, 71%, 45%, 32%, 27%, and 22% respectively. Multivariate analysis adjusted by region identified gross tumor volume (GTV) (odds ratio [OR] ≥100 cm{sup 3}: 2.61; 95% CI: 1.10-6.20; P=.029) and pulmonary function (forced expiratory volume in 1 second [FEV{sub 1}], defined as the ratio of FEV{sub 1} to forced vital capacity [FVC]) (OR <80%: 2.53; 95% CI: 1.09-5.88; P=.030) as significant predictors of 180-day survival. RPA resulted in a 2-class risk stratification system: low-risk (GTV <100 cm{sup 3} or GTV ≥100 cm{sup 3} and FEV{sub 1} ≥80%) and high-risk (GTV ≥100 cm{sup 3} and FEV{sub 1} <80%). The 180-day survival rates were 93% for low risk and 79% for high risk, with an OR of 4.43 (95% CI: 2.07-9.51; P<.001), adjusted by region. A clinical nomogram predictive of 180-day survival, incorporating FEV{sub 1}, GTV, N stage, and maximum esophagus dose yielded favorable calibration (R{sup 2} = 0.947). Conclusions: This analysis identified several risk factors associated with early mortality and suggests that future research in the optimization of pretreatment pulmonary function and/or functional lung avoidance treatment may alter the therapeutic ratio in this patient population.« less

  15. Attained Functional Status Moderates Survival Outcomes of Return to Work After Lung Transplantation.

    PubMed

    Tumin, Dmitry; Kirkby, Stephen E; Tobias, Joseph D; Hayes, Don

    2016-06-01

    Returning to work is a desirable outcome of lung transplantation that is selective on attained functional status. Survival implications of post-transplant employment are unclear. The United Network for Organ Sharing registry was queried for first-time lung transplants performed from May 2005 to March 2015 in patients ages 18-64. Attainment of normal functional status post-transplant, defined as a 100 % score on the Karnofsky Performance Scale (KPS), was examined as moderating 5-year survival outcomes of work resumption, using Cox proportional hazards models. Supplemental analysis examined attainment of forced expiratory volume in 1 s (FEV1) ≥80 % predicted as moderating survival implications of post-transplant employment. Of 10,066 patients, 1824 (18 %) returned to work, while 9078 contributed follow-up data on functional status. Multivariable analysis demonstrated a protective effect of work resumption among patients who did not attain normal functional status before returning to work (HR = 0.62; 95 % CI = 0.51, 0.76; p < 0.001). This association was attenuated among transplant recipients who reached 100 % KPS while still unemployed (p < 0.001). Similarly, post-transplant survival was favorably associated with 5-year survival among patients who did not attain at least 80 % predicted FEV1 before returning to work (HR = 0.71; 95 % CI = 0.59, 0.86; p < 0.001). Early return to work after lung transplantation may benefit patients experiencing mild functional limitations. Timing the resumption of employment to coincide with attainment of maximal functional status around 1 year post transplant should be considered.

  16. Association of lung function and chronic obstructive pulmonary disease with American Heart Association's Life's Simple 7 cardiovascular health metrics.

    PubMed

    Fan, Wenjun; Lee, Hwa; Lee, Angela; Kieu, Chi; Wong, Nathan D

    2017-10-01

    Chronic obstructive pulmonary disease (COPD) is the third leading cause of death in the U.S. There is a strong association between COPD and cardiovascular (CV) disease; however, the relation between COPD and CV health factors is not well defined. We examined the relation between lung function and CV health factors defined by American Heart Association's (AHA) Life's Simple 7 (LS7). We studied 6352 adults aged ≥20 from the National Health and Nutrition Examination Survey (NHANES) 2009-2012. Analysis of variance was used to compare mean FEV1% of predicted across levels of each LS7 metric and population attributable risk was calculated based on COPD prevalence. We also conducted linear regression and logistic regression analyses to determine the association between lung function, COPD and LS7 score. Overall 19.9% of subjects were defined as having COPD. Subjects in the highest categories of the LS7 metrics had the highest mean values of FEV1% of predicted (p < 0.0001 except for total cholesterol). Current smoking and hypertension had a population attributed risk of 21.8% and 21.1% of COPD, respectively. Compared to subjects with 0 ideal health factors, the gender and ethnicity-adjusted odds (95% CI) for COPD were 0.45 (0.22-0.93), 0.22 (0.11-0.43) for those with 4 and 5-7 factors, but adjustment for age attenuated this relation. LS7 score is associated with lung function as well as the odds of COPD that is largely explained by age. Studies are needed to show if promotion of CV health will preserve healthy lung function. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. [The importance of lung volumes in the investigation of heavy smokers].

    PubMed

    Ben Saad, H; Ben Amor, L; Ben Mdalla, S; Ghannouchi, I; Ben Essghair, M; Sfaxi, R; Garrouche, A; Rouatbi, N; Rouatbi, S

    2014-01-01

    Lung hyperinflation (LH) has become a major concern in the management of chronic obstructive pulmonary disease (COPD). To evaluate the role of lung volumes in the positive diagnosis of COPD and in the assessment of airway obstruction reversibility. Three hundred and sixty-six male smokers over the age of 35 with more than 40 pack-years exposure were included in the study. Plethysmographic data were determined before/after taking a bronchodilator (BBD, ABD). Applied definitions: airflow obstruction: BBD FEV1/FVC<0.70. LH: BBD residual volume (RV)>upper limit of normal. Expressions of reversibility: Δvariable=(ABD-BBD) values; Δinit%=Δvariable/BBD value and Δref%=Δvariable/reference value. A 12%init and a 0.2L increase in either FEV1 or FVC or a 10%ref or - 300 mL decrease in RV were considered as clinically significant. Over the 85 smokers without airflow obstruction, 68% had LH. In the hyperinflated group (n=314), and compared to changes in FEV1 and FVC, these RV changes detected more respondents (54% for FEV1 and FVC vs. 65% for RV, P=0.002). This was not the case for the group free from LH (n=52) (23% for FEV1 and FVC vs. 35% for RV, P=0.09). In the 58 hyperinflated groups free from airflow obstruction, and compared to changes in FEV1 and FVC, changes in RV detected more respondents (24% for FEV1 and FVC vs. 71% for RV, P=0.0001). In heavy smokers, it seems essential to include LH as a criterion for a positive diagnosis of COPD and of reversibility evaluation. Copyright © 2013 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  18. Deaths in childhood from cystic fibrosis: 10-year analysis from two London specialist centres.

    PubMed

    Urquhart, Donald S; Thia, Lena P; Francis, Jackie; Prasad, S Ammani; Dawson, Charlie; Wallis, Colin; Balfour-Lynn, Ian M

    2013-02-01

    Death in childhood from cystic fibrosis (CF) is now an uncommon event in the U.K. We wished to assess the circumstances surrounding deaths (and lung transplantation) in the modern era of CF care. A retrospective review was carried out pooling data from two large paediatric specialist CF units in London for the 10-year period 2000-2009 inclusive. There were 11 deaths and eight children who had a lung transplant out of 1022 children cared for in this period. Median age of death was 14.2 years and transplant 13.0 years, with a female preponderance (82% deaths and 75% transplants). Apart from one child (forced expiratory volume in 1 s (FEV1) 69%), lung function indicated severe lung disease (median FEV1 33%, range 12%-69%). Values 5 years prior to death were not predictive (median FEV1 62%, range 32%-96%), and those 1 year prior were similar to the last recorded levels. Almost all (10/11) died in hospital and 5/11 (45%) were ventilated. Respiratory failure was the commonest mode of death (64%). Only four children (36%) were receiving palliative care, and in six cases (55%) care was withdrawn. The number of deaths in children with CF was small but often unpredictable, so active management was continued until late in the majority, reflected by the fact that almost all were in hospital, and more than half were ventilated. If death from respiratory failure is anticipated following a steady decline, palliative care should be instituted well in advance, with attention to appropriate end of life care.

  19. Association between cytochrome P450 3A5 polymorphism and the lung function in Saskatchewan grain workers.

    PubMed

    Seo, Takayuki; Pahwa, Punam; McDuffie, Helen H; Yurube, Keigo; Egoshi, Masayoshi; Umemoto, Yuichiro; Ghosh, Sunita; Fukushima, Yumi; Nakagawa, Kazuko

    2008-06-01

    The activity of the enzymes that metabolize tobacco smoke may affect the susceptibility to chronic obstructive pulmonary disease (COPD). Cytochrome P450 (CYP) 3A5 is expressed selectively over CYP3A4 in human lung, but the association between the CYP3A5 polymorphisms and the airway injury is unknown. Two hundred and six male Saskatchewan grain workers participated in this longitudinal study, and their lung function values of forced expiratory volume in the first second (FEV1) and forced vital capacity (FVC), respiratory symptoms, smoking status, and the occupational history were analyzed. A significant interactive effect was observed between the CYP3A5 genotype and current smoking status on FEV1, and the annual decline rates of FEV1 and FVC in current smokers were greater among CYP3A5*1/*3 carriers than CYP3A5*3/*3 carriers (-48.7+/-16.4 vs. -31.5+/-4.7 ml/years, P=0.02; -27.4+/-18.9 vs. -5.8+/-6.5 ml/years, P=0.04). The incidences of chronic cough and COPD were also higher in current smokers with CYP3A5*1/*3 than in nonsmokers and current smokers with CYP3A5*3/*3. The adjusted odds ratios for chronic cough and COPD current smokers with CYP3A5*1/*3 versus nonsmokers with the CYP3A5*3/*3 genotype were 11.4 (P=0.009) and 4.3 (P=0.13), respectively. The results suggest that CYP3A5*1 may be a novel genetic risk factor for airway injury in smokers, and that CYP3A5 may play a role in airway injury owing to the bioactivation of chemicals in tobacco smoke.

  20. Regional Emphysema Score Predicting Overall Survival, Quality of Life and Pulmonary Function Recovery in Early-stage Lung Cancer Patients

    PubMed Central

    Dai, Jie; Liu, Ming; Swensen, Stephen J.; Stoddard, Shawn M.; Wampfler, Jason A.; Limper, Andrew H.; Jiang, Gening; Yang, Ping

    2017-01-01

    Introduction Pulmonary emphysema is a common comorbidity in lung cancer, but its role in tumor prognosis remains obscure. Our aim was to evaluate the impact of the regional emphysema score (RES) on patient’s overall survival, quality of life (QOL), and pulmonary function recovery in stage I–II lung cancer. Methods Between 1997 and 2009, 1,073 patients were identified and divided into two surgical groups (cancer in emphysematous [group 1, n=565] and non-emphysematous [group 2, n=435] region) and one non-surgical group (group 3, n=73). RES was derived from the emphysematous region and categorized into mild (≤5%), moderate (6–24%) and severe (25–60%). Results In group 1, patients with moderate and severe RES experienced slight decreases in postoperative FEV1, but increases in FEV1/FVC, compared to those with mild RES (p<0.01); however, this correlation was not observed in group 2. Post-treatment QOL was lower in patients with greater RES in all groups mainly due to dyspnea (p<0.05). Cox-regression analysis revealed that patients with higher RES had a significantly poorer survival in both surgical groups, with adjusted HRs of 1.41 and 1.43 for moderate RES and 1.63 and 2.04 for severe RES, respectively; however, this association was insignificant in the non-surgical group (adjusted HR of 0.99 for moderate/severe RES). Conclusions In surgically-treated patients with cancer in emphysematous region, RES is associated with postoperative changes in lung function. RES is also predictive of post-treatment QOL related to dyspnea in early-stage lung cancer. In both surgical groups, RES is an independent predictor of survival. PMID:28126539

  1. Smoking Cessation in COPD Causes a Transient Improvement in Spirometry and Decreases Micronodules on High-Resolution CT Imaging

    PubMed Central

    Dhariwal, Jaideep; Tennant, Rachel C.; Hansell, David M.; Westwick, John; Walker, Christoph; Ward, Simon P.; Pride, Neil; Barnes, Peter J.; Kon, Onn Min

    2014-01-01

    Background: Smoking cessation is of major importance for all smokers; however, in patients with COPD, little information exists on how smoking cessation influences lung function and high-resolution CT (HRCT) scan appearances. Methods: In this single-center study, we performed screening spirometry in a group of heavy smokers aged 40 to 80 years (N = 358). We then studied the effects of smoking cessation in two groups of selected subjects: smokers with COPD (n = 38) and smokers with normal spirometry (n = 55). In parallel to subjects undergoing smoking cessation, we studied a control group of nonsmokers (n = 19). Results: Subjects with COPD who quit smoking had a marked, but transient improvement in FEV1 at 6 weeks (184 mL, n = 17, P < .01) that was still present at 12 weeks (81 mL, n = 17, P < .05) and only partially maintained at 1 year. In contrast, we saw improvement in the transfer factor of lung for carbon monoxide at 6 weeks in both subjects with COPD who quit smoking (0.47 mmol/min/kPa, n = 17, P < .01) and subjects who quit smoking with normal spirometry (0.40 mmol/min/kPa, n = 35, P < .01). An upper-zone single HRCT image slice reliably identified emphysema at baseline in 74% of smokers with COPD (28 of 38) and 29% of healthy smokers (16 of 55). Smoking cessation had no significant effect on the appearances of emphysema but decreased the presence of micronodules on HRCT imaging. Conclusions: Cigarette smoking causes extensive lung function and HRCT image abnormalities, even in patients with normal spirometry. Smoking cessation has differential effects on lung function (FEV1 and gas transfer) and features on HRCT images (emphysema and micronodules). Cessation of smoking in patients with COPD causes a transient improvement in FEV1 and decreases the presence of micronodules, offering an opportunity for concomitant therapy during smoking cessation to augment these effects. Smoking cessation at the earliest possible opportunity is vital to minimize permanent damage to the lungs. PMID:24522562

  2. Heterogeneity in Survival in Adult Patients With Cystic Fibrosis With FEV1 < 30% of Predicted in the United States.

    PubMed

    Ramos, Kathleen J; Quon, Bradley S; Heltshe, Sonya L; Mayer-Hamblett, Nicole; Lease, Erika D; Aitken, Moira L; Weiss, Noel S; Goss, Christopher H

    2017-06-01

    Lung transplantation (LTx) is frequently considered for patients with cystic fibrosis (CF) when the FEV 1 reaches < 30%. This study estimated transplant-free survival for patients with CF and an FEV 1  < 30% and identified predictors of death without LTx. We conducted a retrospective cohort study using the CF Foundation Patient Registry from January 1, 2003 to December 31, 2013. Adult patients (≥ 18 years) with FEV 1  < 30% prior to LTx were included. We performed Kaplan-Meier survival estimates censored at LTx. Multivariable Cox proportional hazard regression identified predictors of mortality. There were 3,340 patients with an FEV 1  < 30%. Death without LTx occurred in 1,250 patients (37.4%); 951 patients (28.5%) underwent LTx; 918 patients (27.5%) remained alive without LTx at the end of follow-up; and 221 patients (6.6%) were lost to follow-up. Median transplant-free survival after FEV 1  < 30% was 6.6 years (95% CI, 5.9-7.0). Adjusted predictors of death without LTx included supplemental oxygen use (hazard ratio [HR], 2.1; 95% CI, 1.7-2.6), Burkholderia cepacia infection (HR, 1.8; 95% CI, 1.3-2.6), BMI ≤ 18 (HR, 1.6; 95% CI, 1.3-1.9), female sex (HR, 1.6; 95% CI, 1.2-2.0), CF-related diabetes in patients receiving insulin (HR, 1.4; 95% CI, 1.2-1.8), and ≥ one exacerbation per year (HR, 1.7; 95% CI, 1.3-2.2 vs. 0 exacerbations). Median survival was > 6.5 years for patients with CF and an FEV 1  < 30%, exceeding prior survival estimates. There was substantial heterogeneity in survival, with some patients with CF dying soon after reaching this lung function threshold and others living for many years. For this reason, we conclude that FEV 1  < 30% remains an important marker of disease severity for patients with CF. Patients with a supplemental oxygen requirement or frequent exacerbations should have prompt referral because of their increased risk of death. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  3. Effects of polymorphic variations in tumor necrosis factor alpha and occupational exposure to grain dust on longitudinal decline in pulmonary function.

    PubMed

    Pahwa, Punam; Nakagawa, Kazuko; Koehncke, Niels; McDuffie, Helen H

    2009-01-01

    Longitudinal declines in pulmonary function are associated with individuals experiencing occupational exposure to organic dusts in combination with lifestyle factors such as cigarette smoking and with genetic factors, and interactions between these factors. To investigate the relationship between polymorphism of genes encoding Tumor Necrosis Factor Alpha (TNF-alpha) and longitudinal lung function decline in grain workers exposed to grain dust. Male grain handlers who participated in the Saskatchewan Grain Workers Surveillance Program from 2002 through 2005 provided demographic, occupational, lifestyle, and respiratory symptoms information as well as pulmonary function measurements and DNA for genotyping. Marginal models using the generalized estimating equations approach were fitted by using a SAS PROC GENMOD to predict the annual decline in Forced Expired Volume in one second (FEV(1)) and Forced Vital Capacity (FVC). Smoking intensity contributed to the decline in FEV(1.)Among *1/*1 homozygotes and *1/*2 heterozygotes, grain workers with <10 years in the grain industry had significantly lower FEV(1)declines compared to those of the other two exposure groups (>10 and < or =20 years, and >20 years in the grain industry). The annual declines in FEV(1)for grain workers who were either *1/*1 homozygote or *1/*2 heterozygote and had been in the grain industry for <10 years were lower by comparison to those of grain workers who were *2/*2 genotype and had been in the industry for <10 years. This research demonstrates that years in the grain industry is an effect modifier between TNF-alpha 308 genotype and longitudinal decline in FEV(1)in male subjects exposed to grain dust.

  4. Annual decline in forced expiratory volume is steeper in aluminum potroom workers than in workers without exposure to potroom fumes

    PubMed Central

    Henneberger, Paul K.; Einvik, Gunnar; Virji, Mohammed Abbas; Bakke, Berit; Kongerud, Johny

    2016-01-01

    Background Aluminum potroom exposure is associated with increased mortality of COPD but the association between potroom exposure and annual decline in lung function is unknown. We have measured lung volumes annually using spirometry from 1986 to 1996. The objective was to compare annual decline in forced expiratory volume in 1 s (dFEV1) and forced vital capacity (dFVC). Methods The number of aluminum potroom workers was 4,546 (81% males) and the number of workers in the reference group was 651 (76% males). The number of spirometries in the index group and the references were 24,060 and 2,243, respectively. Results After adjustment for confounders, the difference in dFEV1 and dFVC between the index and reference groups were 13.5 (P < 0.001) and −8.0 (P = 0.060) ml/year. Conclusion Aluminum potroom operators have increased annual decline in FEV1 relative to a comparable group with non‐exposure to potroom fumes and gases. Am. J. Ind. Med. 59:322–329, 2016. © 2016 The Authors. American Journal of Industrial Medicine Published by Wiley Periodicals, Inc. PMID:26853811

  5. Hyperinflation and intrinsic positive end-expiratory pressure: less room to breathe.

    PubMed

    Krieger, Bruce P

    2009-01-01

    Clinically, the symptoms and limited exercise capabilities of patients with chronic obstructive pulmonary disease (COPD) correlate better with changes in lung volumes than with airflow measurements. The realization of the clinical importance of hyperinflation has been overshadowed for decades by the use of forced expiratory volume during 1 s (FEV(1)) and the ratio of the FEV(1) to the forced expiratory vital capacity (FEV(1)/FVC) to categorize the severity and progression of COPD. Hyperinflation is defined as an elevation in the end-expiratory lung volume or functional residual capacity. When severe hyperinflation encroaches upon inspiratory capacity and limits vital capacity, it results in elevated intrinsic positive end-expiratory pressure (PEEPi) that places the diaphragm at a mechanical disadvantage and increases the work of breathing. Severe hyperinflation is the major physiologic cause of the resulting hypercarbic respiratory failure and patients' inability to transition (i.e. wean) from mechanical ventilatory support to spontaneous breathing. This paper reviews the basic physiologic principles of hyperinflation and its clinical manifestations as demonstrated by PEEPi. Also reviewed are the adverse effects of hyperinflation and PEEPi in critically ill patients with COPD, and methods for minimizing or counterbalancing these effects. Copyright 2009 S. Karger AG, Basel.

  6. The large lungs of elite swimmers: an increased alveolar number?

    PubMed

    Armour, J; Donnelly, P M; Bye, P T

    1993-02-01

    In order to obtain further insight into the mechanisms relating to the large lung volumes of swimmers, tests of mechanical lung function, including lung distensibility (K) and elastic recoil, pulmonary diffusion capacity, and respiratory mouth pressures, together with anthropometric data (height, weight, body surface area, chest width, depth and surface area), were compared in eight elite male swimmers, eight elite male long distance athletes and eight control subjects. The differences in training profiles of each group were also examined. There was no significant difference in height between the subjects, but the swimmers were younger than both the runners and controls, and both the swimmers and controls were heavier than the runners. Of all the training variables, only the mean total distance in kilometers covered per week was significantly greater in the runners. Whether based on: (a) adolescent predicted values; or (b) adult male predicted values, swimmers had significantly increased total lung capacity ((a) 145 +/- 22%, (mean +/- SD) (b) 128 +/- 15%); vital capacity ((a) 146 +/- 24%, (b) 124 +/- 15%); and inspiratory capacity ((a) 155 +/- 33%, (b) 138 +/- 29%), but this was not found in the other two groups. Swimmers also had the largest chest surface area and chest width. Forced expiratory volume in one second (FEV1) was largest in the swimmers ((b) 122 +/- 17%) and FEV1 as a percentage of forced vital capacity (FEV1/FVC)% was similar for the three groups. Pulmonary diffusing capacity (DLCO) was also highest in the swimmers (117 +/- 18%). All of the other indices of lung function, including pulmonary distensibility (K), elastic recoil and diffusion coefficient (KCO), were similar. These findings suggest that swimmers may have achieved greater lung volumes than either runners or control subjects, not because of greater inspiratory muscle strength, or differences in height, fat free mass, alveolar distensibility, age at start of training or sternal length or chest depth, but by developing physically wider chests, containing an increased number of alveoli, rather than alveoli of increased size. However, in this cross-sectional study, hereditary factors cannot be ruled out, although we believe them to be less likely.

  7. Glycopyrronium once-daily significantly improves lung function and health status when combined with salmeterol/fluticasone in patients with COPD: the GLISTEN study—a randomised controlled trial

    PubMed Central

    Frith, Peter A; Thompson, Philip J; Ratnavadivel, Rajeev; Chang, Catherina L; Bremner, Peter; Day, Peter; Frenzel, Christina; Kurstjens, Nicol

    2015-01-01

    Background The optimal use of various therapeutic combinations for moderate/severe chronic obstructive pulmonary disease (COPD) is unclear. The GLISTEN trial compared the efficacy of two long-acting anti-muscarinic antagonists (LAMA), when combined with an inhaled corticosteroid (ICS) and a long-acting β2 agonist (LABA). Methods This randomised, blinded, placebo-controlled trial in moderate/severe COPD patients compared once-daily glycopyrronium (GLY) 50 µg, once-daily tiotropium (TIO) 18 µg or placebo (PLA), when combined with salmeterol/fluticasone propionate (SAL/FP) 50/500 µg twice daily. The primary objective was to determine the non-inferiority of GLY+SAL/FP versus TIO+SAL/FP on trough FEV1 after 12 weeks. An important secondary objective was whether addition of GLY to SAL/FP was better than SAL/FP alone. Results 773 patients (mean FEV1 57.2% predicted) were randomised; 84.9% completed the trial. At week 12, GLY+SAL/FP demonstrated non-inferiority to TIO+SAL/FP for trough FEV1: least square mean treatment difference (LSMdiff) −7 mL (SE 17.4) with a lower limit for non-inferiority of −60 mL. There was significant increase in week 12 trough FEV1 with GLY+SAL/FP versus PLA+SAL/FP (LSMdiff 101 mL, p<0.001). At 12 weeks, GLY+SAL/FP produced significant improvement in St George's Respiratory Questionnaire total score versus PLA+SAL/FP (LSMdiff −2.154, p=0.02). GLY+SAL/FP demonstrated significant rescue medication reduction versus PLA+SAL/FP (LSMdiff −0.72 puffs/day, p<0.001). Serious adverse events were similar for GLY+SAL/FP, TIO+SAL/FP and PLA+SAL/FP with an incidence of 5.8%, 8.5% and 5.8%, respectively. Conclusions GLY+SAL/FP showed comparable improvements in lung function, health status and rescue medication to TIO+SAL/FP. Importantly, addition of GLY to SAL/FP demonstrated significant improvements in lung function, health status and rescue medication compared to SAL/FP. Trial registration number NCT01513460. PMID:25841237

  8. Imaging Phenotype of Occupational Endotoxin-Related Lung Function Decline.

    PubMed

    Lai, Peggy S; Hang, Jing-Qing; Zhang, Feng-Ying; Sun, J; Zheng, Bu-Yong; Su, Li; Washko, George R; Christiani, David C

    2016-09-01

    Although occupational exposures contribute to a significant proportion of obstructive lung disease, the phenotype of obstructive lung disease associated with work-related organic dust exposure independent of smoking remains poorly defined. We identified the relative contributions of smoking and occupational endotoxin exposure to parenchymal and airway remodeling as defined by quantitative computed tomography (CT). The Shanghai Textile Worker Study is a longitudinal study of endotoxin-exposed cotton workers and endotoxin-unexposed silk workers that was initiated in 1981. Spirometry, occupational endotoxin exposure, and smoking habits were assessed at 5-year intervals. High-resolution computed tomography (CT) was performed in 464 retired workers in 2011, along with quantitative lung densitometric and airway analysis. Significant differences in all CT measures were noted across exposure groups. Occupational endotoxin exposure was associated with a decrease (-1.3%) in percent emphysema (LAAI-950), a 3.3-Hounsfield unit increase in 15th percentile density, an 18.1-g increase in lung mass, and a 2.3% increase in wall area percent. Current but not former smoking was associated with a similar CT phenotype. Changes in LAAI-950 were highly correlated with 15th percentile density (correlation -1.0). Lung mass was the only measure associated with forced expiratory volume in 1 sec (FEV1) decline, with each 10-g increase in lung mass associated with an additional loss (-6.1 mL) of FEV1 (p = 0.001) between 1981 and 2011. There are many similarities between the effects of occupational endotoxin exposure and those of tobacco smoke exposure on lung parenchyma and airway remodeling. The effects of occupational endotoxin exposure appear to persist even after the cessation of exposure. LAAI-950 may not be a reliable indicator of emphysema in subjects without spirometric impairment. Lung mass is a CT-based biomarker of accelerated lung function decline. Lai PS, Hang J, Zhang F, Sun J, Zheng BY, Su L, Washko GR, Christiani DC. 2016. Imaging phenotype of occupational endotoxin-related lung function decline. Environ Health Perspect 124:1436-1442; http://dx.doi.org/10.1289/EHP195.

  9. Associations between Ambient Particulate Matter and Nitrogen Dioxide and Chronic Obstructive Pulmonary Diseases in Adults and Effect Modification by Demographic and Lifestyle Factors

    PubMed Central

    Leem, Jong Han; Kim, Hwan Cheol

    2018-01-01

    This study was undertaken to investigate the associations between chronic exposure to particulate matter of medium aerodynamic diameter ≤10 or ≤2.5 µm (PM10 or PM2.5) and nitrogen dioxide (NO2) levels and lung function and to examine a possible change in these relationships by demographic and lifestyle factors. Chronic obstructive pulmonary disease (COPD) was defined using the Global Initiative for COPD criteria (forced expiratory volume in 1 second (FEV1)/forced vital capacity (FVC) of <70%). Associations of lung function and COPD with PM10 or PM2.5 or NO2 were examined using linear and logistic regression analyses among 1264 Korean adults. The highest tertiles of PM2.5 (≥37.1 μg/m3) and NO2 (≥53.8 μg/m3) exposure were significantly associated with COPD (highest versus lowest tertile of PM2.5: adjusted odds ratio (OR) = 1.79, 95% CI: 1.02–3.13; highest versus lowest tertile of NO2: adjusted OR = 1.83, 95% CI: 1.04–3.21). A 10 μg/m3 increase in PM10 concentration was associated with a 1.85 L (95% CI –3.65 to –0.05) decrease in FEV1 and a 1.73 L (95% CI –3.35 to –0.12) decrease in FVC, with the strongest negative association among older people and those with less education. Reduced lung function was associated with PM2.5 exposure in subjects with no physical activity. This study provides evidence that exposure to ambient air pollution has adverse effects on lung function in adults. PMID:29463050

  10. Respiratory health effects of fifteen years of improved collective protection in a wheat-processing worker population.

    PubMed

    Dorribo, Victor; Wild, Pascal; Pralong, Jacques A; Danuser, Brigitta; Reboux, Gabriel; Krief, Peggy; Niculita-Hirzel, Hélène

    2015-01-01

    Occupational exposure to grain dust causes respiratory symptoms and pathologies. To decrease these effects, major changes have occurred in the grain processing industry in the last twenty years. However, there are no data on the effects of these changes on workers' respiratory health. The aim of this study was to evaluate the respiratory health of grain workers and farmers involved in different steps of the processing industry of wheat, the most frequently used cereal in Europe, fifteen years after major improvements in collective protective equipment due to mechanisation. Information on estimated personal exposure to wheat dust was collected from 87 workers exposed to wheat dust and from 62 controls. Lung function (FEV1, FVC, and PEF), exhaled nitrogen monoxide (FENO) and respiratory symptoms were assessed after the period of highest exposure to wheat during the year. Linear regression models were used to explore the associations between exposure indices and respiratory effects. Acute symptoms - cough, sneezing, runny nose, scratchy throat - were significantly more frequent in exposed workers than in controls. Increased mean exposure level, increased cumulative exposure and chronic exposure to more than 6 mg.m (-3) of inhaled wheat dust were significantly associated with decreased spirometric parameters, including FEV1 and PEF (40 ml and 123 ml.s (-1) ), FEV1 and FVC (0.4 ml and 0.5 ml per 100 h.mg.m (-3) ), FEV1 and FVC (20 ml and 20 ml per 100 h at >6 mg.m (-3) ). However, no increase in FENO was associated with increased exposure indices. The lung functions of wheat-related workers are still affected by their cumulative exposure to wheat dust, despite improvements in the use of collective protective equipment.

  11. Pulmonary Impairment in Tuberculosis Survivors: The Korean National Health and Nutrition Examination Survey 2008-2012.

    PubMed

    Jung, Jae-Woo; Choi, Jae-Chol; Shin, Jong-Wook; Kim, Jae-Yeol; Choi, Byoung-Whui; Park, In-Won

    2015-01-01

    Pulmonary tuberculosis (TB) can affect lung function, but studies regarding long-term follow-up in patients with no sequelae on chest X-ray (CXR) have not been performed. We evaluated lung functional impairment and persistent respiratory symptoms in those with prior pulmonary TB and those with prior pulmonary TB with no residual sequelae on CXR, and determined risk factors for airflow obstruction. We used data from adults aged ≥ 40 years from the annual Korean National Health and Nutrition Examination Surveys conducted between 2008 and 2012. P values for comparisons were adjusted for age, sex, and smoking status. In total of 14,967 adults, 822 subjects (5.5%) had diagnosed and treated pulmonary TB (mean 29.0 years ago). The FVC% (84.9 vs. 92.6), FEV1% (83.4 vs. 92.4), and FEV1/FVC% (73.4 vs. 77.9) were significantly decreased in subjects with prior pulmonary TB compared to those without (p < 0.001, each). In 12,885 subjects with no sequalae on CXR, those with prior pulmonary TB (296, 2.3%) had significantly lower FEV1% (90.9 vs. 93.4, p = 0.001) and FEV1/FVC% (76.6 vs. 78.4, p < 0.001) than those without. Subjects with prior pulmonary TB as well as subjects with no sequalae on CXR were more likely to experience cough and physical activity limitations due to pulmonary symptoms than those without prior pulmonary TB (p < 0.001, each). In total subjects, prior pulmonary TB (OR, 2.314; 95% CI, 1.922-2.785), along with age, male, asthma, and smoking mount was risk factor for airflow obstruction. In subjects with prior pulmonary tuberculosis, inactive TB lesion on chest x-ray (OR, 2.300; 95% CI, 1.606-3.294) were risk factors of airflow obstruction. In addition to subjects with inactive TB lesion on CXR, subjects with no sequelae on CXR can show impaired pulmonary function and respiratory symptoms. Prior TB is a risk factor for airflow obstruction and that the risk is more important when they have inactive lesions on chest X-ray. Hence, the patients with treated TB should need to have regular follow-up of lung function and stop smoking for early detection and prevention of the chronic airway disease.

  12. A novel sidestream ultrasonic flow sensor for multiple breath washout in children.

    PubMed

    Fuchs, Susanne I; Sturz, J; Junge, S; Ballmann, M; Gappa, M

    2008-08-01

    Inert gas multiple breath washout (MBW) for measuring Lung Clearance Index using mass spectrometry and 4% sulfur hexafluoride (SF(6)) as the tracer gas has been shown to be sensitive for detecting early Cystic Fibrosis (CF) lung disease. However, mass spectrometry requires bulky equipment and is expensive to buy and maintain. A novel sidestream ultrasonic device may overcome this problem. The aims of this study were to assess the feasibility and clinical validity of measuring lung volume (functional residual capacity, FRC) and the LCI using the sidestream ultrasonic flow sensor in children and adolescents with CF in relation to spirometry and plain chest radiographs. MBW using the sidestream ultrasonic device and conventional spirometry were performed in 26 patients with CF and 22 healthy controls. In the controls (4.7-17.7 years) LCI was similar to that reported using mass spectrometry (mean (SD) 6.7 (0.5)). LCI was elevated in 77% of the CF children (6.8-18.9 years), whereas spirometry was abnormal in only 38.5%, 61.5%, and 26.9% for FEV(1), MEF(25), and FEV(1)/FVC, respectively. This was more marked in children <10 years. LCI correlated with the Crispin-Norman score, whereas FEV(1) did not. Sidestream ultrasonic MBW is a valid and simple alternative to mass spectrometry for assessing ventilation homogeneity in children. (c) 2008 Wiley-Liss, Inc.

  13. The natural history of adult pulmonary Langerhans cell histiocytosis: a prospective multicentre study.

    PubMed

    Tazi, Abdellatif; de Margerie, Constance; Naccache, Jean Marc; Fry, Stéphanie; Dominique, Stéphane; Jouneau, Stéphane; Lorillon, Gwenaël; Bugnet, Emmanuelle; Chiron, Raphael; Wallaert, Benoit; Valeyre, Dominique; Chevret, Sylvie

    2015-03-14

    The natural history of pulmonary Langerhans cell histiocytosis (PLCH) has been unclear due to the absence of prospective studies. The rate of patients who experience an early progression of their disease is unknown. Additionally, conflicting effects of smoking cessation on the outcome of PLCH have been reported. In this prospective, multicentre study, 58 consecutive patients with newly diagnosed PLCH were comprehensively evaluated over a two-year period. Our objectives were to estimate the incidence of early progression of the disease and to evaluate the impact of smoking status on lung function outcomes. Lung function deterioration was defined as a decrease of at least 15% in FEV1 and/or FVC and/or DLCO, compared with baseline values. At each visit, smoking status was recorded based on the patients' self-reports and urinary cotinine measurements that were blinded for the patients. The cumulative incidence of lung function outcomes over time was estimated using the non-parametric Kaplan-Meier method. Multivariate Cox models with time-dependent covariates were used to calculate the hazards ratios of the lung function deterioration associated with smoking status with adjustment for potential confounders. The cumulative incidence of lung function deterioration at 24 months was 38% (22% for FEV1 and DLCO, and 9% for FVC). In the multivariate analysis, smoking status and PaO2 at inclusion were the only factors associated with the risk of lung function deterioration. The patients' smoking statuses markedly changed over time. Only 20% of the patients quit using tobacco for the entire study period. Nevertheless, being a non-smoker was associated with a decreased risk of subsequent lung function deterioration, even after adjustment for baseline predictive factors. By serial lung computed tomography, the extent of cystic lesions increased in only 11% of patients. Serial lung function evaluation on a three- to six-month basis is essential for the follow-up of patients with recently diagnosed PLCH to identify those who experience an early progression of their disease. These patients are highly addicted to tobacco, and robust efforts should be undertaken to include them in smoking cessation programs. ClinicalTrials.gov: No: NCT01225601 .

  14. T2* measurements of 3-T MRI with ultrashort TEs: capabilities of pulmonary function assessment and clinical stage classification in smokers.

    PubMed

    Ohno, Yoshiharu; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Keiko; Takahashi, Masaya; Van Cauteren, Marc; Sugimura, Kazuro

    2011-08-01

    The purpose of this study was to determine the usefulness of MRI with ultrashort TEs on a 3-T system and of thin-section MDCT for pulmonary function assessment and clinical stage classification of chronic obstructive pulmonary disease (COPD) in smokers. Forty smokers (24 men and 16 women; mean age ± SD, 68.0 ± 9.3 years) underwent MRI with ultrashort TEs and thin-section MDCT. Pulmonary function testing was also performed to determine the following: the ratio of forced expiratory volume in 1 second to forced vital capacity (percentage predicted) (FEV(1/)FVC%), percentage predicted forced expiratory volume in 1 second (%FEV(1)), and percentage predicted diffusing capacity of lung for carbon monoxide corrected for alveolar volume (%DLCO/V(A)). All subjects were classified into one of four groups as follows: smokers without COPD, with mild COPD, with moderate COPD, and with severe or very severe COPD. T2(*) maps were expressed using proprietary software. Regional T2(*) values were determined by region of interest measurements and were averaged to determine a mean T2(*) value for each subject. CT-based functional lung volume and the ratio of the wall area to the total airway area were also determined. All indexes were statistically correlated with pulmonary function parameters. Then, all indexes were compared among all groups by means of Tukey's honest significance test. All indexes had significant correlation with FEV(1)/FVC%, %FEV(1), and % DLCO/V(A) (p < 0.05). All indexes except WA% of smokers without COPD and smokers with mild COPD differed significantly from those of smokers with moderate COPD and smokers with severe or very severe COPD (p < 0.05). Moreover, the mean T2(*) value of the moderate COPD group was significantly different from that of the severe or very severe COPD group (p < 0.05). MRI with ultrashort TEs is potentially as useful as quantitatively assessed MDCT for pulmonary function loss assessment and clinical stage classification of COPD in smokers.

  15. Genetic Variants in the Hedgehog Interacting Protein Gene Are Associated with the FEV1/FVC Ratio in Southern Han Chinese Subjects with Chronic Obstructive Pulmonary Disease

    PubMed Central

    Zhang, Zili; Wang, Jian; Zheng, Zeguang; Chen, Xindong; Zeng, Xiansheng; Zhang, Yi; Li, Defu; Shu, Jiaze; Yang, Kai; Lai, Ning; Dong, Lian

    2017-01-01

    Background Convincing evidences have demonstrated the associations between HHIP and FAM13a polymorphisms and COPD in non-Asian populations. Here genetic variants in HHIP and FAM13a were investigated in Southern Han Chinese COPD. Methods A case-control study was conducted, including 989 cases and 999 controls. The associations between SNPs genotypes and COPD were performed by a logistic regression model; for SNPs and COPD-related phenotypes such as lung function, COPD severity, pack-year of smoking, and smoking status, a linear regression model was employed. Effects of risk alleles, genotypes, and haplotypes of the 3 significant SNPs in the HHIP gene on FEV1/FVC were also assessed in a linear regression model in COPD. Results The mean FEV1/FVC% value was 46.8 in combined COPD population. None of the 8 selected SNPs apparently related to COPD susceptibility. However, three SNPs (rs12509311, rs13118928, and rs182859) in HHIP were associated significantly with the FEV1/FVC% (Pmax = 4.1 × 10−4) in COPD adjusting for gender, age, and smoking pack-years. Moreover, statistical significance between risk alleles and the FEV1/FVC% (P = 2.3 × 10−4), risk genotypes, and the FEV1/FVC% (P = 3.5 × 10−4) was also observed in COPD. Conclusions Genetic variants in HHIP were related with FEV1/FVC in COPD. Significant relationships between risk alleles and risk genotypes and FEV1/FVC in COPD were also identified. PMID:28929109

  16. Respiratory function in pregnancy at sea level and at high altitude.

    PubMed

    McAuliffe, Fionnuala; Kametas, Nikos; Espinoza, Jimmy; Greenough, Anne; Nicolaides, Kypros

    2004-04-01

    To determine the effect of pregnancy on respiratory function in a non-Caucasian group and determine whether there was an interaction between pregnancy and altitude of residence. Prospective cross sectional study. Antenatal clinics in Peru, at sea level in Lima and at high altitude in Cerro de Pasco. Peruvian women with singleton pregnancies; 122 living at sea level and 192 living at 4300 m altitude in the Peruvian Andes. At each location, 19 non-pregnant women were also studied. Respiratory function was measured in pregnant and non-pregnant women living at sea level and at 4300 m. Forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), peak expiratory flow rate (PEFR), total lung capacity (TLC), inspiratory capacity (IC), residual volume (RV), expiratory residual volume (ERV) and functional residual capacity (FRC). At sea level, RV and TLC were higher in the third compared with the first trimester (P < 0.05). At high altitude, FEV1 (P < 0.01), ERV (P < 0.01) and FRC (P < 0.01) were lower in the third compared with the first trimester. Pregnant and non-pregnant women at high altitude were 4 cm shorter (P < 0.0001) and had larger lung volumes (P < 0.01); their total lung capacities were approximately 1 L greater than women living at sea level (P < 0.0001). These results suggest that the effect of pregnancy on the respiratory function of healthy women is influenced by altitude of residence.

  17. The Effect of Wood Aerosols and Bioaerosols on the Respiratory Systems of Wood Manufacturing Industry Workers in Golestan Province

    PubMed Central

    Badirdast, Phateme; Salehpour, Soussan; Ghadjari, Ali; Khodakarim, Soheila; Panahi, Davod; Fadaei, Moslem; Rahimi, Abolfazl

    2017-01-01

    Background: Occupational exposure to dust leads to acute and chronic respiratory diseases, occupational asthma, and depressed lung function. In the light of a lack of comprehensive studies on the exposure of Iranian workers to wood dusts, the objective of this study was to monitor the occupational exposure to wood dust and bioaerosol, and their correlation with the lung function parameters in chipboard manufacturing industry workers. Materials and Methods: A cross-sectional study was conducted on chipboard workers in Golestan Province; a total of 150 men (100 exposed cases and 50 controls) were assessed. Workers were monitored for inhalable wood dust and lung function parameters, i.e., FVC, FEV1, FEV1/FVC, and FEF25–75%. The workers’ exposure to bioaerosols was measured using a bacterial sampler; a total of 68 area samples were collected. The analysis was performed using the Mann-Whitney, Kruskal-Wallis, and regression statistical tests. Results: The geometric mean value and geometric standard deviation of inhalable wood dust for the exposed and control groups were 19 ± 2.00 mg/m3 and 0.008 ± 0.001 mg/m3, respectively. A statistically significant correlation was observed between the lung parameters and cumulative exposure to inhalable wood dust, whereas a statistically significant correlation was not observed between the lung parameters and bioaerosol exposure. However, the exposure of Iranian workers to bioaerosols was higher, compared to their foreign coworkers. Conclusion: Considering the high level of exposure among workers in this study along with their lung function results, long-term exposure to wood dust may be detrimental to the workers’ health and steps to limit their exposure should be considered seriously. PMID:28638425

  18. Severity of Kyphosis and Decline in Lung Function: The Framingham Study.

    PubMed

    Lorbergs, Amanda L; O'Connor, George T; Zhou, Yanhua; Travison, Thomas G; Kiel, Douglas P; Cupples, L Adrienne; Rosen, Hillel; Samelson, Elizabeth J

    2017-05-01

    Hyperkyphosis reduces the amount of space in the chest, mobility of the rib cage, and expansion of the lungs. Decline in pulmonary function may be greater in persons with more severe kyphosis; however, no prospective studies have assessed this association. We conducted a longitudinal study to quantify the impact of kyphosis severity on decline in pulmonary function over 16 years in women and men. Participants included a convenience sample of 193 women and 82 men in the Framingham Study original cohort (mean age: 63 years; range: 50-79 years), who had measurements of kyphosis angle from lateral spine radiographs obtained in 1972-1976 and forced expiratory volume in 1 second (FEV1) from spirometry taken four times over 16 (±1.87) years from 1972 through 1988. Kyphosis severity was associated with greater decline in FEV1 in women but not in men. Adjusted mean change in FEV1 over 16 years was -162, -245, and -261mL (trend, p = .02) with increasing tertile of kyphosis angle in women and -372, -297, and -257mL (trend, p = .20) in men, respectively. This longitudinal study found that kyphosis severity increased subsequent decline in pulmonary function in women but not in men. Reasons for an association between kyphosis and pulmonary function in women but in not men may be due, at least in part, to the small number of men in our study. Nevertheless, our findings suggest that preventing or slowing kyphosis progression may reduce the burden of pulmonary decline in older adults. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Challenges in Collating Spirometry Reference Data for South-Asian Children: An Observational Study

    PubMed Central

    Lum, Sooky; Bountziouka, Vassiliki; Quanjer, Philip; Sonnappa, Samatha; Wade, Angela; Beardsmore, Caroline; Chhabra, Sunil K.; Chudasama, Rajesh K.; Cook, Derek G.; Harding, Seeromanie; Kuehni, Claudia E.; Prasad, K. V. V.; Whincup, Peter H.; Lee, Simon; Stocks, Janet

    2016-01-01

    Availability of sophisticated statistical modelling for developing robust reference equations has improved interpretation of lung function results. In 2012, the Global Lung function Initiative(GLI) published the first global all-age, multi-ethnic reference equations for spirometry but these lacked equations for those originating from the Indian subcontinent (South-Asians). The aims of this study were to assess the extent to which existing GLI-ethnic adjustments might fit South-Asian paediatric spirometry data, assess any similarities and discrepancies between South-Asian datasets and explore the feasibility of deriving a suitable South-Asian GLI-adjustment. Methods Spirometry datasets from South-Asian children were collated from four centres in India and five within the UK. Records with transcription errors, missing values for height or spirometry, and implausible values were excluded(n = 110). Results Following exclusions, cross-sectional data were available from 8,124 children (56.3% male; 5–17 years). When compared with GLI-predicted values from White Europeans, forced expired volume in 1s (FEV1) and forced vital capacity (FVC) in South-Asian children were on average 15% lower, ranging from 4–19% between centres. By contrast, proportional reductions in FEV1 and FVC within all but two datasets meant that the FEV1/FVC ratio remained independent of ethnicity. The ‘GLI-Other’ equation fitted data from North India reasonably well while ‘GLI-Black’ equations provided a better approximation for South-Asian data than the ‘GLI-White’ equation. However, marked discrepancies in the mean lung function z-scores between centres especially when examined according to socio-economic conditions precluded derivation of a single South-Asian GLI-adjustment. Conclusion Until improved and more robust prediction equations can be derived, we recommend the use of ‘GLI-Black’ equations for interpreting most South-Asian data, although ‘GLI-Other’ may be more appropriate for North Indian data. Prospective data collection using standardised protocols to explore potential sources of variation due to socio-economic circumstances, secular changes in growth/predictors of lung function and ethnicities within the South-Asian classification are urgently required. PMID:27119342

  20. Constrictive Bronchiolitis in Cystic Fibrosis Adolescents with Refractory Pulmonary Decline.

    PubMed

    Harris, William T; Boyd, J Todd; McPhail, Gary L; Brody, Alan S; Szczesniak, Rhonda D; Korbee, Leslie L; Baker, Michael L; Clancy, John P

    2016-12-01

    Refractory lung function decline in association with recurrent pulmonary exacerbations is a common, yet poorly explained finding in cystic fibrosis (CF). To investigate the histopathologic mechanisms of pulmonary deterioration during adolescence and early adulthood, we reviewed clinically-indicated lung biopsy specimens obtained during a period of persistent decline. To determine if peribronchiolar remodeling is prominent in lung biopsy specimens obtained in adolescents with CF refractory to conventional therapy. Six adolescents with CF (mean age, 16.2 y; mean FEV 1 , 52% predicted at biopsy) with significant pulmonary deterioration over 12-24 months (mean FEV 1 decline of 14% predicted/year) despite aggressive intervention underwent computed tomography imaging and ultimately lung biopsy to aid clinical management. In addition to routine clinical evaluation, histopathologic investigation included staining for transforming growth factor-β (TGF-β, a genetic modifier of CF lung disease), collagen deposition (a marker of fibrosis), elastin (to evaluate for bronchiectasis), and α-smooth muscle actin (to identify myofibroblasts). All computed tomography scans demonstrated a mix of bronchiectasis and hyperinflation that was variable across lung regions and within patients. Lung biopsy revealed significant peribronchiolar remodeling, particularly in patients with more advanced disease, with near complete obliteration of the peribronchiolar lumen (constrictive bronchiolitis). Myofibroblast differentiation (a TGF-β-dependent process) was prominent in specimens with significant airway remodeling. Constrictive bronchiolitis is widely present in the lung tissue of adolescents with CF with advanced disease and may contribute to impaired lung function that is refractory to conventional therapy (antibiotics, antiinflammatories, and mucolytics). TGF-β-dependent myofibroblast differentiation is prominent in areas of active fibrogenesis and may foster small airway remodeling in CF lung disease.

  1. Lung function and respiratory symptoms among female hairdressers in Palestine: a 5-year prospective study

    PubMed Central

    Nemer, Maysaa; Kristensen, Petter; Nijem, Khaldoun; Bjertness, Espen; Skare, Øivind; Skogstad, Marit

    2015-01-01

    Objectives Hairdressers are exposed to chemicals at the workplace which are known to cause respiratory symptoms and asthma. This study aimed to examine changes in self-reported respiratory symptoms over 5 years, as well as to examine the lung function decline and determine whether it is within the expected range, to assess the dropout rate and reasons for leaving the profession, and to examine the associations between occupational factors and lung function changes at follow-up. Design Prospective study. Setting Female hairdressing salons in Hebron city, Palestine. Participants 170 female hairdressers who participated in a baseline survey in 2008 were followed up in 2013. A total of 161 participants participated in 2013. Outcome measures Change in reported respiratory symptoms and change in lung function over follow-up. Dropout from the profession and reasons for it. Differences between current and former hairdressers in respiratory symptoms and lung function at follow-up. Ambient air ammonia levels in 13 salons. Results Current hairdressers reported more respiratory symptoms in 2013 compared with baseline. Former hairdressers reported fewer symptoms at follow-up. At follow-up, current hairdressers showed a significant decrease in forced vital capacity of 35 mL/year (95% CI 26 to 44 mL/year) and of 31 mL/year (95% CI 25 to 36 mL/year) for forced expiratory volume in 1 s (FEV1). 28 (16%) of the hairdressers quit the job during the 5-year follow-up, 8 (28%) because of health problems. Hairdressers who had been working for 4 years or more at baseline showed a stronger decline in FEV1 compared with those who worked less than 4 years (difference 13, 95% CI 1 to 25). Conclusions Current hairdressers developed more respiratory symptoms and larger lung function decline than former hairdressers during follow-up. Few hairdressers left their profession because of respiratory health problems. Working for more years is associated with lung function decline among current hairdressers. PMID:26474935

  2. Lung function and blood markers of nutritional status in non-COPD aging men with smoking history: a cross-sectional study.

    PubMed

    Shiozawa, Nobuyoshi; Hayashimoto, Kanae; Suzuki, Etsuji; Kikuchi, Hiroshi; Takata, Shingo; Ashida, Kozo; Watanabe, Masutaka; Hosaki, Yasuhiro; Mitsunobu, Fumihiro

    2010-08-09

    Cigarette smoking and advanced age are well known as risk factors for chronic obstructive pulmonary disease (COPD), and nutritional abnormalities are important in patients with COPD. However, little is known about the nutritional status in non-COPD aging men with smoking history. We therefore investigated whether reduced lung function is associated with lower blood markers of nutritional status in those men. This association was examined in a cross-sectional study of 65 Japanese male current or former smokers aged 50 to 80 years: 48 without COPD (non-COPD group), divided into tertiles according to forced expiratory volume in one second as percent of forced vital capacity (FEV(1)/FVC), and 17 with COPD (COPD group). After adjustment for potential confounders, lower FEV(1)/FVC was significantly associated with lower red blood cell count (RBCc), hemoglobin, and total protein (TP); not with total energy intake. The difference in adjusted RBCc and TP among the non-COPD group tertiles was greater than that between the bottom tertile in the non-COPD group and the COPD group. In non-COPD aging men with smoking history, trends toward reduced nutritional status and anemia may independently emerge in blood components along with decreased lung function even before COPD onset.

  3. Effects of ambient air pollution from municipal solid waste landfill on children's non-specific immunity and respiratory health.

    PubMed

    Yu, Yunjiang; Yu, Ziling; Sun, Peng; Lin, Bigui; Li, Liangzhong; Wang, Zhengdong; Ma, Ruixue; Xiang, Mingdeng; Li, Hui; Guo, Shu

    2018-05-01

    This cross-sectional study investigated the association between air pollutant (AP) and respiratory health of 951 children residing near a municipal solid waste (MSW) landfill in Northern China. Results showed that students in non-exposure areas had significantly higher levels of lysozyme, secretory immunoglobulin A (SIgA), and better lung capacity than students in exposure areas (p < .05). Multiple regression model analysis indicated that lysozyme levels exhibited a consistent negative association with methane (CH 4 : β = -76.3, 95% CI -105 to -47.7) and sulfuretted hydrogen (H 2 S: β = -11.7, 95% CI -20.2 to -3.19). In addition, SIgA levels were negatively associated with H 2 S (β = -68.9, 95% CI -97.9 to -39.9) and ammonia (NH 3 : β = -30.3, 95% CI -51.7 to -8.96). Among all AP, H 2 S and sulfur dioxide (SO 2 ) were the most robustly related with reduced lung function. H 2 S exposure was negatively associated with six lung function indices, 1-s forced expiratory volume (FEV1%), mean forced expiratory flow between 25% and 75% (MMF), maximum voluntary ventilation (MVV), and forced expiratory flow at 25%, 50%, and 75% of the pulmonary volume (FEF25, FEF50, FEF75); and SO 2 was negatively associated with FEV1%, MVV, FEF25, FEF50 and FEF75. Our results suggested that AP exposure was negatively associated with more lung function parameters in boys than in girls. In conclusion, our findings suggested that children living adjacent to landfill sites were more likely to have deficient non-specific immunity and impaired lung function. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. [Analysis of correlation between pulmonary function and expression levels of matrix metalloproteinases-9 and tissue inhibitor of metalloproteinase-1 among toluene diisocyanate exposed workers].

    PubMed

    Miao, P P; Meng, T; Jia, Q; Niu, Y; Ye, M; Ji, Y Q; Ju, R; Chen, X L; Shao, H; Zheng, Y X; Dai, Y F

    2016-05-01

    To investigate the effect of occupational toluene diisocyanate(TDI) exposure on matrix metalloproteinases-9 (MMP-9) and tissue inhibitor of metalloproteinase-1(TIMP-1), and analysis of the correlation of MMP-9,TIMP-1,MMP-9/TIMP-1 and lung function. In October 2014, based on cluster sampling, we conducted a cross-sectional study in a TDI production factory located in China's western region. 61 exposed workers were recruited from workers engaged in packing, operating and checking. Based on different levels of the external exposure, the packers were classified as high exposed group, while operators and checkers as low exposed group. 58 factory managers, matching age and agent, were selected as controls, having same work intense and not contacting the TDI or other allergens. The questionnaire surveys were used to obtain the agent, age, work age, smoking and drinking, personal and family allergic history, occupational history, and the recent health conditions. The levels of MMP-9 and TIMP-1 in serum of subjects were determind by ELISA. The time weighted average concentrations (8h-TWA) were used to describe the levels of TDI air exposure in working environment. Spearman correlation assay was used to investigate the correlation of MMP-9, TIMP-1, MMP-9/TIMP-1 and lung function, exposure time. 8-hour TWA means of TDI air levels in exposed group, packers, operators and checkers were 0.39, 0.76, 0.25 mg/m(3), respectively . According to the external exposure concentration, the packers were classified as high exposed group, and the operators and checkers were classified as low exposed group. In controls, low exposed group and high exposed group, the levels of MMP-9, respectively, were (807.21±347.70),(586.91±317.50),(388.94±312.01) ng/ml (χ(2)=16.69, P<0.001), respectively, and the P50(P25-P75) of MMP-9/TIMP-1 were 4.67(2.87-6.68), 2.3(1.44-3.48), 1.11(0.59-1.48) (χ(2)=39.42, P<0.001), respectively, and the concentrations of TIMP-1, were (173.44±72.67), (236.12±51.98), (302.81±44.39) ng/ml (F=20.09, P< 0.001), respectively. The levels P50(P25-P75) of FVC, FEV1.0 and FEV1.0/FVC in exposed group were, 92.8% (86.0%-101.8%), 85.5%(76.7%-92.8%), 112.5(108.2-118.5), respectively, which were lower than that in control group (124.3%(107.9%-144.2%), 142.7%(119.1%-155.7%), 129.2(123.5-134))(Z values were 7.70, 8.97, 8.62, and all P<0.001). Spearman rank correlation analysis showed that levels of MMP-9 were positively associated with FEV1.0, and FEV1.0/FVC (r values were 0.27, 0.25, respectively, all P<0.05), and The levels of TIMP-1 were negatively associated with FVC, FEV1.0, and FEV1.0/FVC (r valuse were -0.33, -0.39, -0.39, all P<0.05).The levels of MMP-9 were negatively correlated with exposure time(r=-0.26, P=0.040). The positive correlations of MMP-9/TIMP-1 with FVC, FEV1.0, and FEV1.0/FVC were also found (r valuse were 0.34, 0.44, 0.40, all P<0.05). TDI exposure could induce the downs of MMP-9 and MMP-9/TIMP-1 associated with lung functions. The MMP-9 and MMP-9/TIMP-1,in a way, could reflect the respiratory inflammatory injury caused by TDI exposure.

  5. Impulse oscillometry system as an alternative diagnostic method for chronic obstructive pulmonary disease.

    PubMed

    Wei, Xia; Shi, Zhihong; Cui, Yajuan; Mi, Jiuyun; Ma, Zhengquan; Ren, Jingting; Li, Jie; Xu, Shudi; Guo, Youmin

    2017-11-01

    We aimed to compare impulse oscillation system (IOS) and traditional pulmonary function tests (PFTs) for the assessment of the severity of chronic obstructive pulmonary disease (COPD), and to assess the use of IOS parameters to identify patients who were forced expiratory volume in 1 second (FEV1)%pred < 50%.Patients with COPD (n = 215) were enrolled at the Ninth Hospital of Xi'an Affiliated Hospital of Xi'an Jiaotong University between October 2014 and September 2016. All patients were assessed by traditional PFT and IOS. Diagnostic performance of IOS parameters to determine indication for patients of FEV1%pred < 50% was assessed on receiver-operating characteristics (ROC) curve analysis.Out of 215 patients, 18, 83, 78, and 36 patients were classified as grade 1, 2, 3, and 4, respectively, according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) severity grading. On Spearman correlation analysis, FEV1%pred, MMEF 75%-25%, and residual volume/total lung capacity (RV/TLC) correlated with total respiratory impedance (Z5)%pred, resistance at 5 Hz (R5)-resistance at 20 Hz (R20), R5-R20% R5, R5, R5%pred, frequency response (Fres), reactance area (Ax), and reactance at 5 Hz (X5). On ROC curve analysis, the area under the curve (AUC) of X5 absolute value, Fres, Ax, Z5%pred, R5-R20, and R5-R20% R5 were 0.748, 0.755, 0.760, 0.705, 0.715, and 0.735, respectively, for COPD patients who required inhalational glucocorticoid therapy.IOS parameters showed a good correlation with traditional pulmonary function parameters; reactance parameters showed a stronger correlation than that of the resistance parameters. IOS can be used as an alternative method for pulmonary function assessment in patients with COPD with FEV1%pred < 50% who need inhalational glucocorticoid therapy. ChiCTR-OCH-14004904.

  6. Impulse oscillometry system as an alternative diagnostic method for chronic obstructive pulmonary disease

    PubMed Central

    Wei, Xia; Shi, Zhihong; Cui, Yajuan; Mi, Jiuyun; Ma, Zhengquan; Ren, Jingting; Li, Jie; Xu, Shudi; Guo, Youmin

    2017-01-01

    Abstract We aimed to compare impulse oscillation system (IOS) and traditional pulmonary function tests (PFTs) for the assessment of the severity of chronic obstructive pulmonary disease (COPD), and to assess the use of IOS parameters to identify patients who were forced expiratory volume in 1 second (FEV1)%pred < 50%. Patients with COPD (n = 215) were enrolled at the Ninth Hospital of Xi’an Affiliated Hospital of Xi’an Jiaotong University between October 2014 and September 2016. All patients were assessed by traditional PFT and IOS. Diagnostic performance of IOS parameters to determine indication for patients of FEV1%pred < 50% was assessed on receiver-operating characteristics (ROC) curve analysis. Out of 215 patients, 18, 83, 78, and 36 patients were classified as grade 1, 2, 3, and 4, respectively, according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) severity grading. On Spearman correlation analysis, FEV1%pred, MMEF 75%–25%, and residual volume/total lung capacity (RV/TLC) correlated with total respiratory impedance (Z5)%pred, resistance at 5 Hz (R5)-resistance at 20 Hz (R20), R5-R20% R5, R5, R5%pred, frequency response (Fres), reactance area (Ax), and reactance at 5 Hz (X5). On ROC curve analysis, the area under the curve (AUC) of X5 absolute value, Fres, Ax, Z5%pred, R5-R20, and R5-R20% R5 were 0.748, 0.755, 0.760, 0.705, 0.715, and 0.735, respectively, for COPD patients who required inhalational glucocorticoid therapy. IOS parameters showed a good correlation with traditional pulmonary function parameters; reactance parameters showed a stronger correlation than that of the resistance parameters. IOS can be used as an alternative method for pulmonary function assessment in patients with COPD with FEV1%pred < 50% who need inhalational glucocorticoid therapy. Clinical trial registration number: ChiCTR-OCH-14004904. PMID:29145259

  7. Inhaled dry powder mannitol in children with cystic fibrosis: A randomised efficacy and safety trial.

    PubMed

    De Boeck, K; Haarman, E; Hull, J; Lands, L C; Moeller, A; Munck, A; Riethmüller, J; Tiddens, H; Volpi, S; Leadbetter, J; Charlton, B; Malfroot, A

    2017-05-01

    Inhaled mannitol has beneficial effects on lung function, mucociliary clearance, quality of life and sputum properties. This trial examined the efficacy of inhaled mannitol in children with cystic fibrosis (CF). The efficacy of inhaled mannitol in children with CF aged 6-17years was assessed in a phase 2, randomised, placebo-controlled crossover study. Subjects were randomly assigned to mannitol 400mg every 12h or matching placebo for 8weeks, followed by an 8week washout and an 8week period with the alternate treatment. The primary endpoint was the absolute change from baseline in ppFEV1 (percent predicted FEV1). A total of 92 subjects were studied, with a mean age of 12years and mean baseline ppFEV1 of 72.2%. During mannitol treatment ppFEV1 was 3.42% (p=0.004) higher compared to placebo or a 4.97% (p=0.005) relative difference; relative change from baseline FEF25-75 was 10.52% (p=0.013). During mannitol treatment, acute post-treatment sputum weight was higher (p=0.012). In pre-specified subgroups (rhDNase use, age, and disease severity), the treatment differences consistently favoured mannitol. The most common AEs were cough and pulmonary exacerbations. Pulmonary exacerbation AEs were approximately 30% lower in the mannitol group. In children with CF, inhaled mannitol was associated with significant improvements in lung function and sputum weight, irrespective of rhDNase use, age or disease severity. Inhaled mannitol was well tolerated and was associated with a reduced incidence of pulmonary exacerbation AEs. (Clinical Trials.Gov: NCT 01883531). Copyright © 2017 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  8. The effect of habitual waterpipe tobacco smoking on pulmonary function and exercise capacity in young healthy males: A pilot study.

    PubMed

    Hawari, F I; Obeidat, N A; Ghonimat, I M; Ayub, H S; Dawahreh, S S

    2017-01-01

    Evidence regarding the health effects of habitual waterpipe smoking is limited, particularly in young smokers. Respiratory health and cardiopulmonary exercise tests were compared in young male habitual waterpipe smokers (WPS) versus non-smokers. 69 WPS (≥3 times/week for three years) and 69 non-smokers were studied. Respiratory health was assessed through the American Thoracic Society and the Division of Lung Diseases (ATS-DLD-78) adult questionnaire. Pulmonary function and cardiopulmonary exercise tests were performed. Self-reported respiratory symptoms, forced expiratory volume in first second (FEV 1 ), forced vital capacity (FVC), FEV 1 /FVC ratio, forced expiratory flow between 25 and 75% of FVC (FEF 25-75% ), peak expiratory flow (PEF), exercise time, peak end-tidal CO 2 tension (PetCO 2 ), subject-reported leg fatigue and dyspnea; peak O 2 uptake (VO 2 max), and end-expiratory lung volume (EELV) change from baseline (at peak exercise) were measured. WPS were more likely than non-smokers to report respiratory symptoms. WPS also demonstrated: shorter exercise time; lower peak VO 2 ; higher perceived dyspnea at mid-exercise; lower values of the following: FEV 1 , FVC, PEF, and EELV change. Habitual waterpipe tobacco smoking in young seemingly healthy individuals is associated with a greater burden of respiratory symptoms and impaired exercise capacity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. [Quantitative analysis of emphysema and air trapping at inspiratory and expiratory phase multi-slice spiral CT scan in smokers: correlation with pulmonary function test].

    PubMed

    Zhang, D; Guan, Y; Fan, L; Xia, Y; Liu, S Y

    2018-05-22

    Objective: To quantify emphysema and air trapping at inspiratory and expiratory phase multi-slice spiral CT(MSCT) scanning in smokers without respiratory symptoms, and analyze the correlation between the CT quantifiable parameters and lung function parameters. Methods: A total of 72 smokers, who underwent medical examinations from September 2013 to September 2016 in Changzheng Hospital were enrolled in this research and were divided into two groups: 24 smokers with COPD and 48 smokers without COPD.Besides, thirty-nine non-smokers with normal pulmonary function were enrolled as the controls.All subjects underwent double phase MSCT scanning and pulmonary function tests.CT quantifiable parameters of emphysema included the low attenuation area below a threshold of -950 Hounsfield Units (HU)(LAA%(-950)), the lowest 15th percentile of the histogram of end-inspiratory attenuation values (P(15-IN)), the lowest 15th percentile of the histogram of end-expiratory attenuation values (P(15-EX)), relative volume change(RVC) and the expiratory to inspiratory ratio of mean lung density (E/I(MLD)). Pulmonary function parameters included forced expiratory volume in 1 second expressed as percent predicted (FEV(1)%), forced expiratory volume in one second to forced vital capacity ratio (FEV(1)/FVC), residual volume to total lung capacity ratio (RV/TLC) and carbon monoxide diffusion capacity corrected for alveolar volume (DLCO/VA). The differences of CT quantifiable parameters and pulmonary function parameters among the three groups were analyzed by using one-way analysis of variance or Kruskal - Wallis H test.The correlation between CT quantifiable parameters and pulmonary function parameters was analyzed by using Spearman ' s correlation analysis. Results: The differences of LAA%(-950)(the values for the controls, the group of smokers with out COPD and the group of smokers with COPD were 0.5%±0.7%, 0.7%±1.2% and 2.0%±2.4% respectively), P(15-IN)(the values of the three groups were (-892±33), (-905±15) and (-907±22) HU respectively), FEV(1)%(the values of the three groups were 88.4%±8.8%, 84.2%±7.5% and 82.1%±8.0% respectively), FEV(1)/FVC(the values of the three groups were 78.0%±3.8%, 76.6%±4.3% and 67.3%±5.5% respectively), DLCO/VA (the values of the three groups were (1.36±0.25), (1.30±0.22) and (1.21±0.22) mmol·min(-1)·kPa(-1)·L(-1) respectively) and RV/TLC (the values of the three groups were 49.5%±6.6%, 45.9%±6.0% and 53.0%±6.4% respectively) among the three groups were statistically significant (all P <0.05). In the control group, LAA%(-950) negatively correlated with FEV(1)/FVC and DLCO/VA( r =-0.32, P =0.04; r =-0.69, P =0.00) and neither did P(15-IN) with FEV(1)%( r =-0.14, P =0.02). Inversely, P(15-IN) positively correlated with DLCO/VA ( r =0.55, P =0.00). In the group of smokers without COPD, LAA%(-950) negatively correlated with FEV(1)/FVC and DLCO/VA( r =-0.31, P =0.04; r =-0.42, P =0.00), and P(15-IN) positively correlated with FEV(1)/FVC and DLCO/VA ( r =0.33, P =0.02; r =0.30, P =0.04). In the group of smokers with COPD, LAA%(-950) negatively correlated with DLCO/VA ( r =-0.62, P =0.00), but positively correlated with RV/TLC ( r =0.59, P =0.00). And P(15-IN) positively correlated with DLCO/VA( r =0.53, P =0.01). Conclusions: Smokers emphysema and air trapping can be effectively evaluated by double phase MSCT. Moreover, two of the CT quantifiable parameters, LAA%(-950) and P(15-IN), are highly sensitive to changes in pulmonary function.

  10. Effect of gas cooking on lung function in adolescents: modifying role of sex and immunoglobulin E.

    PubMed

    Corbo, G M; Forastiere, F; Agabiti, N; Dell'Orco, V; Pistelli, R; Aebischer, M L; Valente, S; Perucci, C A

    2001-07-01

    A study was undertaken to investigate the effect of gas cooking on the lung function of adolescents while considering serum IgE level as a possible effect modifier. The cross sectional study was performed in 702 subjects aged 11-13 years from primary and secondary schools in Civitavecchia and Viterbo ( Latium region in Central Italy), categorised according to how often they were in the kitchen while the mother cooked (never, sometimes, often). Data were collected by questionnaire and lung function was measured by spirometric tests. Bronchial hyperresponsiveness was evaluated by the methacholine test, atopic status by a skin prick test, and a blood sample was collected to determine serum IgE levels. The results were analysed separately for boys and girls. Multiple regression analysis was performed, taking functional parameters (FEV(1), FEV(1)/FVC, FEF(25-75), FEF(50), FEF(75)) as the dependent variables and age, height, parental smoking, and father's education as independent variables. There was no association between time spent in the kitchen and lung function level in boys, but a reduction in lung function was detected in girls which was statistically significant for FEF(75) (sometimes -10.3%, often -11.1%). After stratifying boys and girls into four groups on the basis of the IgE serum level (below and above the median value of IgE), the reduction in lung function was significant in girls with a high IgE value whereas no significant deleterious effects were evident in girls with a low IgE value or in boys with either a low or high IgE. The results remained substantially unchanged after excluding girls with a response to methacholine below the concentration of 4 mg/ml, asthmatic patients, and those with positive skin prick tests. Gas cooking has a harmful effect on the lung function of girls with a high serum level of IgE. We do not know whether serum IgE, a marker of allergic susceptibility, is a simple indicator that an inflammatory process is in progress or whether it is involved in the pathogenesis of injury leading to bronchial obstruction.

  11. WE-FG-206-08: Pulmonary Functional Imaging Biomarkers of NSCLC to Guide and Optimize Functional Lung Avoidance Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheikh, Khadija; Capaldi, Dante PI; Parraga, Grace

    Purpose: Functional lung avoidance radiotherapy promises optimized therapy planning by minimizing dose to well-functioning lung and maximizing dose to the rest of the lung. Patients with NSCLC commonly present with co-morbid COPD and heterogeneously distributed ventilation abnormalities stemming from emphysema, airways disease, and tumour burden. We hypothesized that pulmonary functional imaging methods may be used to optimize radiotherapy plans to avoid regions of well-functioning lung and significantly improve outcomes like quality-of-life and survival. To ascertain the utility of functional lung avoidance therapy in clinical practice, we measured COPD phenotypes in NSCLC patients enrolled in a randomized-controlled-clinical-trial prior to curative intentmore » therapy. Methods: Thirty stage IIIA/IIIB NSCLC patients provided written informed consent to a randomized-controlled-clinical-trial ( http://clinicaltrials.gov/ct2/show/NCT02002052 ) comparing outcomes in patients randomized to standard or image-guided radiotherapy. Hyperpolarized noble gas MRI ventilation-defect-percent (VDP) (Kirby et al, Acad Radiol, 2012) as well as CT-emphysema measurements were determined. Patients were stratified based on quantitative imaging evidence of ventilation-defects and emphysema into two subgroups: 1) tumour-specific ventilation defects only (TSD), and, 2) tumour-specific and other ventilation defects with and without emphysema (TSD{sub VE}). Receiver-operating-characteristic (ROC) curves were used to characterize the performance of clinical measures as predictors of the presence of non-tumour specific ventilation defects. Results: Twenty-one out of thirty subjects (70%) had non-tumour specific ventilation defects (TSD{sub VE}) and nine subjects had ONLY tumour-specific defects (TSD). Subjects in the TSD{sub VE} group had significantly greater smoking-history (p=.006) and airflow obstruction (FEV{sub 1}/FVC) (p=.001). ROC analysis demonstrated an 87% classification rate for smoking pack-years, 90% for FEV{sub 1}/FVC, and 56% for tumour RECIST measurements for identifying patients with non-tumour and tumour-specific ventilation abnormalities. Conclusion: 70% of NSCLC patients had ventilation abnormalities stemming from emphysema, airways disease and tumour burden. Smoking-history and airflow obstruction, but not RECIST, identified NSCLC patients with ventilation abnormalities appropriate for functional lung avoidance therapy.« less

  12. The impact of treatment with indacaterol in patients with COPD: A post-hoc analysis according to GOLD 2011 categories A to D.

    PubMed

    Kerstjens, Huib A M; Deslée, Gaëtan; Dahl, Ronald; Donohue, James F; Young, David; Lawrence, David; Kornmann, Oliver

    2015-06-01

    Indacaterol is an inhaled, once-daily, ultra-long-acting β2-agonist for the treatment of chronic obstructive pulmonary disease (COPD). We report on the effectiveness of indacaterol and other bronchodilators compared with placebo in patients across the Global Initiative for Chronic Obstructive Lung Disease (GOLD) 2011 categories A to D. A post-hoc, subgroup pooled analysis of 6-month efficacy data from three randomized, placebo-controlled, parallel-group studies involving 3862 patients was performed across GOLD 2011 categories A to D, according to baseline forced expiratory volume in 1 s (FEV1) % predicted, modified Medical Research Council (mMRC) dyspnea scale, and exacerbation history in the 12 months prior to entry. Efficacy of once-daily indacaterol 150 and 300 μg, open-label tiotropium 18 μg, twice-daily salmeterol 50 μg, and formoterol 12 μg was compared with placebo. End points analysed were trough FEV1, transition dyspnea index (TDI), and St George's Respiratory Questionnaire (SGRQ) total score, all at Week 26, and mean rescue medication use over 26 weeks. Indacaterol 150 and 300 μg significantly improved FEV1, compared with placebo across all GOLD groups. Indacaterol 150 and 300 μg also significantly improved TDI, SGRQ total score, and mean rescue medication use compared with placebo across most GOLD subgroups. Treatment selection according to patient's symptoms as well as lung function is an important consideration in maintenance treatment of COPD. Indacaterol 150 and 300 μg effectively improved lung function and symptoms in patients across all GOLD 2011 categories. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Pulmonary function in adolescents with ataxia telangiectasia.

    PubMed

    McGrath-Morrow, Sharon; Lefton-Greif, Maureen; Rosquist, Karen; Crawford, Thomas; Kelly, Amber; Zeitlin, Pamela; Carson, Kathryn A; Lederman, Howard M

    2008-01-01

    Pulmonary complications are common in adolescents with ataxia telangiectasia (A-T), however objective measurements of lung function may be difficult to obtain because of underlying bulbar weakness, tremors, and difficulty coordinating voluntary respiratory maneuvers. To increase the reliability of pulmonary testing, minor adjustments were made to stabilize the head and to minimize leaks in the system. Fifteen A-T adolescents completed lung volume measurements by helium dilution. To assess for reproducibility of spirometry testing, 10 A-T adolescents performed spirometry on three separate occasions. Total lung capacity (TLC) was normal or just mildly decreased in 12/15 adolescents tested. TLC correlated positively with functional residual capacity (FRC), a measurement independent of patient effort (R2=0.71). The majority of individuals had residual volumes (RV) greater than 120% predicted (10/15) and slow vital capacities (VC) less than 70% predicted (9/15). By spirometry, force vital capacity (FVC) and forced expiratory volume in 1 sec (FEV1) values were reproducible in the 10 individuals who underwent testing on three separate occasions (R=0.97 and 0.96 respectively). Seven of the 10 adolescents had FEV1/FVC ratios>90%. Lung volume measurements from A-T adolescents revealed near normal TLC values with increased RV and decreased VC values. These findings indicate a decreased ability to expire to residual volume rather then a restrictive defect. Spirometry was also found to be reproducible in A-T adolescents suggesting that spirometry testing may be useful for tracking changes in pulmonary function over time in this population. Copyright (c) 2007 Wiley-Liss, Inc.

  14. Quantification of atopy, lung function and airway hypersensitivity in adults

    PubMed Central

    2011-01-01

    Background Studies in children have shown that concentration of specific serum IgE (sIgE) and size of skin tests to inhalant allergens better predict wheezing and reduced lung function than the information on presence or absence of atopy. However, very few studies in adults have investigated the relationship of quantitative atopy with lung function and airway hyperresponsiveness (AHR). Objective To determine the association between lung function and AHR and quantitative atopy in a large sample of adults from the UK. Methods FEV1 and FVC (% predicted) were measured using spirometry and airway responsiveness by methacholine challenge (5-breath dosimeter protocol) in 983 subjects (random sample of 800 parents of children enrolled in a population-based birth cohort enriched with 183 patients with physician-diagnosed asthma). Atopic status was assessed by skin prick tests (SPT) and measurement of sIgE (common inhalant allergens). We also measured indoor allergen exposure in subjects' homes. Results Spirometry was completed by 792 subjects and 626 underwent methacholine challenge, with 100 (16.0%) having AHR (dose-response slope>25). Using sIgE as a continuous variable in a multiple linear regression analysis, we found that increasing levels of sIgE to mite, cat and dog were significantly associated with lower FEV1 (mite p = 0.001, cat p = 0.0001, dog p = 2.95 × 10-8). Similar findings were observed when using the size of wheal on skin testing as a continuous variable, with significantly poorer lung function with increasing skin test size (mite p = 8.23 × 10-8, cat p = 3.93 × 10-10, dog p = 3.03 × 10-15, grass p = 2.95 × 10-9). The association between quantitative atopy with lung function and AHR remained unchanged when we repeated the analyses amongst subjects defined as sensitised using standard definitions (sIgE>0.35 kUa/l, SPT-3 mm>negative control). Conclusions In the studied population, lung function decreased and AHR increased with increasing sIgE levels or SPT wheal diameter to inhalant allergens, suggesting that atopy may not be a dichotomous outcome influencing lung function and AHR. PMID:22410099

  15. Prediction of lung function response for populations exposed to a wide range of ozone conditions

    EPA Science Inventory

    Abstract Context: A human exposure-response (E-R) model that has previously been demonstrated to accurately predict population mean FEV1 response to ozone exposure has been proposed as the foundation for future risk assessments for ambient ozone. Objective: Fit the origi...

  16. Pulmonary function test in traffic police personnel in Pondicherry.

    PubMed

    Pal, Pravati; John, Robert A; Dutta, T K; Pal, G K

    2010-01-01

    Traffic policemen working in the busy traffic signal areas get exposed to the vehicular emissions for years together. The fumes, chemicals and particles present in the emission are reported to be damaging to the lung functions of these individuals. Since there were no data available on the PFT parameters of traffic police personnel of Pondicherry, this study was taken up to assess the effect of traffic air pollution on their pulmonary functions. PFT parameters were recorded in age- and BMI-matched 30 traffic police personnel (study group) and 30 general police personnel (control group) of male gender. As chronic smoking is known to be a critical factor in altering lung function, PFT parameters were compared between the smokers as well as nonsmokers of both the groups. In nonsmokers, there was significant decrease in VC (P < 0.05), FEV1 (P < 0.01), FEF-25 (P < 0.05) and PIF (P < 0.05) in study group compared to the control group. In smokers, there was significant decrease in VC (P < 0.05), FEV1 (P <00001), PEF (P < 0.0001), MVV (P < 0.0001), FEF-25 (P < 0.0001), and PIF (P < 0.01) in study group compared to the control group. These changes indicate restriction to the lung expansion, obstruction and narrowing of the airways in traffic police personnel compared to the general police personnel. This may be due to exposure to vehicular pollution for several hours in a day for many years causing decreased functional capacity of the lungs and chronic smoking worsens the condition.

  17. Lung function not affected by asbestos exposure in workers with normal Computed Tomography scan.

    PubMed

    Schikowsky, Christian; Felten, Michael K; Eisenhawer, Christian; Das, Marco; Kraus, Thomas

    2017-05-01

    It has been suggested that asbestos exposure affects lung function, even in the absence of asbestos-related pulmonary interstitial or pleural changes or emphysema. We analyzed associations between well-known asbestos-related risk factors, such as individual cumulative asbestos exposure, and key lung function parameters in formerly asbestos-exposed power industry workers (N = 207) with normal CT scans. For this, we excluded participants with emphysema, fibrosis, pleural changes, or any combination of these. The lung function parameters of FVC, FEV1, DLCO/VA, and airway resistance were significantly associated with the burden of smoking, BMI and years since end of exposure (only DLCO/VA). However, they were not affected by factors directly related to amount (eg, cumulative exposure) or duration of asbestos exposure. Our results confirm the well-known correlation between lung function, smoking habits, and BMI. However, we found no significant association between lung function and asbestos exposure. © 2017 Wiley Periodicals, Inc.

  18. ROLE OF GENETIC SUSCEPTIBILITY TO LATENT ADENOVIRAL INFECTION AND DECREASED LUNG FUNCTION

    PubMed Central

    Kasuga, Ikuma; Hogg, James C.; Paré, Peter D.; Hayashi, Shizu; Sedgwick, Edward G.; Ruan, Jian; Wallace, Alison M.; He, Jian-Qing; Zhang, Xiaozhu; Sandford, Andrew J.

    2009-01-01

    Background Latent adenoviral infection may amplify cigarette smoke-induced lung inflammation and therefore play an important role in the development of chronic obstructive pulmonary disease (COPD). Adenoviruses can evade the human immune response via their 19-kDa protein (19K) which delays the expression of class I human leukocyte antigen (HLA) proteins. The 19K protein shows higher affinity to HLA-B7 and A2 compared with HLA-A1 and A3. The receptor for adenovirus (CXADR) and integrin β5 (ITGB5) are host factors which might affect adenovirus infection. Therefore, we investigated the contribution of HLA, CXADR, and ITGB5 genetic variants to the presence of the E1A gene and to level of lung function. Methods Study subjects were assayed for HLA-B7, A1, A2 and A3 by PCR-based assays using allele-specific primers. Polymorphisms of the CXADR and ITGB5 genes were genotyped by PCR-based restriction fragment length polymorphism assays. Detection of adenoviral E1A gene was performed by a real-time PCR TaqMan assay. Results E1A positive individuals have a lower FEV1 compared with E1A negative individuals. However, there was no significant difference in E1A positivity rate between the high (HLA-B7 and A2) and low (HLA-A1 and A3) 19K affinity groups. There was also no significant difference in FEV1 level between each affinity group. There was no significant difference in E1A positivity rate or lung function among the CXADR and ITGB5 genotypes. Conclusions Genetic variants in HLA, CXADR and ITGB5 do not influence latent adenoviral infections and are not associated with COPD. PMID:19502044

  19. The protective effect of a beta 2 agonist against excessive airway narrowing in response to bronchoconstrictor stimuli in asthma and chronic obstructive lung disease.

    PubMed Central

    Bel, E. H.; Zwinderman, A. H.; Timmers, M. C.; Dijkman, J. H.; Sterk, P. J.

    1991-01-01

    Beta 2 agonists reduce airway hypersensitivity to bronchoconstrictor stimuli acutely in patients with asthma and chronic obstructive lung disease. To determine whether these drugs also protect against excessive airway narrowing, the effect of inhaled salbutamol on the position and shape of the dose-response curves for histamine or methacholine was investigated in 12 patients with asthma and 11 with chronic obstructive lung disease. After pretreatment with salbutamol (200 or 400 micrograms) or placebo in a double blind manner dose-response curves for inhaled histamine and methacholine were obtained by a standard method on six days in random order. Airway sensitivity was defined as the concentration of histamine or methacholine causing a 20% fall in FEV1 (PC20). A maximal response plateau on the log dose-response curve was considered to be present if two or more data points for FEV1 fell within a 5% response range. In the absence of a plateau, the test was continued until a predetermined level of severe bronchoconstriction was reached. Salbutamol caused an acute increase in FEV1 (mean increase 11.5% predicted in asthma, 7.2% in chronic obstructive lung disease), and increase in PC20 (mean 15 fold in asthma, fivefold in chronic obstructive lung disease), and an increase in the slope of the dose-response curves in both groups. In subjects in whom a plateau of FEV1 response could be measured salbutamol did not change the level of the plateau. In subjects without a plateau salbutamol did not lead to the development of a plateau, despite achieving a median FEV1 of 44% predicted in asthma and 39% in chronic obstructive lung disease. These results show that, although beta 2 agonists acutely reduce the airway response to a given strength of bronchoconstrictor stimulus, they do not protect against excessive airflow obstruction if there is exposure to relatively strong stimuli. This, together with the steepening of the dose-response curve, could be a disadvantage of beta 2 agonists in the treatment of moderate and severe asthma or chronic obstructive lung disease. PMID:1871705

  20. [Use of COPD-6 Vitalograph in Primary Care as tool for smoking cessation].

    PubMed

    Antón-García, F; Pruteanu, D F; Correcher-Salvador, E

    2016-03-01

    To assess the evolution of smoking cessation process after using a COPD-6 Vitalograph in smokers that came to a primary care practice (PCP) during a three year period (March 2011- February 2013). To assess if there are any new COPD diagnoses and to compare the smoking cessation outcomes to those of a specific smoking cessation practice (SSCP) from another healthcare centre. Two devices were used: Vitalograph (electronic device measuring the lung function) and the CO-oximeter, in 176 patients (active search of smokers). tobacco pack-years, tobacco dependence (shortened Fagerström test), CO in exhaled breath (in parts per million-ppm), personal history of COPD or cardiovascular disease (CVD). The patients performed three forced exhalations and the Vitalograph registered the lung function (FEV1, FEV6, FEV1/FEV6) and the estimated lung age (ELA). Patient attitude was assessed (phases: pre-contemplation, contemplation, preparation) before and after the test, informing them of the outcomes. Patient progress in the smoking cessation process was also recorded. A total of 176 smokers were studied in PCP and 33 in SSCP. PCP/SSCP: age: 45.9/51.6 years old (p=042); pack-years 25.5/39.3 (p=0001); patients who quit smoking and used medicines for it 2/9. In PCP: age-ELA 45.9/57.4 (p=0.000). In SSCP: age-ELA 51.6/74.3 (p=000). Smoking habit evolution PCP/SSCP: cessation 24.5%/48.5% (p=004). Difference 24%. CI difference (6.4-42.8%). In PCP new COPD diagnosis in 6 smokers. COPD-6 Vitalograph is a fast and easy to use tool in day-to-day practice. The percentage of smoking cessation is better in SSCP, although a high smoking cessation rate was obtained in PCP (active search). Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  1. [Pulmonary function in patients with infiltrative pulmonary tuberculosis].

    PubMed

    Nefedov, V B; Popova, L A; Shergina, E A

    2007-01-01

    Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/VC%, PEF, MEF25, MEF50, MEF75, TLC, TGV, pulmonary residual volume (PRV), R(aw), R(in),, R(ex), DLCO-SB, DLCO-SS, PaO2, and PaCO2 were determined in 103 patients with infiltrative pulmonary tuberculosis. Pulmonary dysfunction was detected in 83.5% of the patients. Changes were found in lung volumes and capacities in 63.1%, impaired bronchial patency and pulmonary gas exchange dysfunction were in 60.2 and 41.7%, respectively. The changes in pulmonary volumes and capacities appeared as increased PRV, decreased VC and FVC, and decreased and increased TGV and TLC; impaired bronchial patency presented as decreased PEF, MEF25, MEF50, MEF75, FEV1/VC% and increased R(aw) R(in), and R(ex); pulmonary gas exchange dysfunction manifested itself as reduced DLCO-SB, DLCO-SS, and PaO2 and decreased and increased PaCO2. The magnitude of the observed functional changes was generally slight. Significant disorders were observed rarely and very pronounced ones were exceptional.

  2. [Pulmonary function in patients with disseminated pulmonary tuberculosis].

    PubMed

    Nefedov, V B; Shergina, E A; Popova, L A

    2007-01-01

    Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/VC%, PEF, MEF25%, MEF50%, MEF75%, TLS, TGV, pulmonary residual volume (PRV), Raw, Rin, Rex, DLCO-SB, DLCO-SS, PaO2, and PaCO2 were determined in 29 patients with disseminated pulmonary tuberculosis. Pulmonary dysfunction was detected in 93.1% of the patients. Changes were found in lung volumes and capacities in 65.5%, impaired bronchial patency and pulmonary gas exchange dysfunction were in 79.3 and 37.9%, respectively. The changes in pulmonary volumes and capacities appeared as increased PRV, decreased VC, FVC, and TLS, decreased and increased TGV; impaired bronchial patency presented as decreased PEF, MEF25%, MEF50%, MEF75%, and FEV1/VC% and increased Raw, Rin, and Rex; pulmonary gas exchange dysfunction manifested itself as reduced DLCO-SS and PaO2 and decreased and increased PaCO2. The observed functional changes varied from slight to significant and pronounced with a preponderance of small disorders, a lower detection rate of significant disorders, and rare detection of very pronounced ones.

  3. Pulmonary functions in patients with subclinical hypothyroidism.

    PubMed

    Cakmak, Gulfidan; Saler, Tayyibe; Saglam, Zuhal Aydan; Yenigun, Mustafa; Ataoglu, Esra; Demir, Tuncalp; Temiz, Levent Umit

    2011-10-01

    To determine whether alterations in pulmonary function takes place in subclinical hypothyroidism by examining the diffusion lung capacity and muscle strength of such patients. This is a descriptive study conducted in 2009 at Haseki Training and Research Hospital, Istanbul, Turkey. Hundred and twenty-six patients with subclinical hypothyroidism and 58 age and sex matched individuals were recruited. Simple spirometry tests were performed, and pulmonary diffusion capacity (DLco) and muscle strength were measured. ScH patients showed a significant reduciton of the following pulmonary function tests (% predicted value) as compared with control subjects: FVC, FEV1, FEV1%, FEF25-75, FEF25-75%, DLco, DLco/VA, Pimax, Pimax% and Pemax%. These data indicate that pulmonary functions are effected in subclinical hypothyrodism. Therefore patients with or who are at high risk of having subclinical hypothyroidism, should be subjected to evaluation of pulmonary functions with simple spirometry.

  4. Impact of exposure to insulation wool on lung function and cough in Swedish construction workers

    PubMed Central

    Albin, M.; Engholm, G.; Hallin, N.; Hagmar, L.

    1998-01-01

    OBJECTIVES: To investigate whether application of insulation wool adversely affects lung volumes and increases the occurrence of symptoms of airway irritation. METHODS: Data from nationwide health check ups in 1981-93 of male construction workers born in 1955 or later were used to investigate cross sectional (n = 96,004) and longitudinal (n = 26,298) associations between lung volumes, vital capacity (VC), and forced expiratory volume in one second (FEV1) and exposure to insulation wool by combining a job exposure matrix (JEM) and self reported exposure. Data on 12 month prevalence of persistent cough not associated with the common cold was available for the period 1989-92. Potential confounding from smoking, exposure to asbestos, silica, and isocyanates, was considered in the analyses. RESULTS: For those in the highest exposure category (self reported duration of exposure of > or = 11 years, and high exposure according to the JEM) VC was on average 2.5 cl lower (95% CI -6.5 to 1.5) than in those with no exposure. The corresponding figures for FEV1 was -2.4 cl (95% CI -6.1 to 1.3). In the longitudinal analyses, the yearly change in VC between the first and last spirometry for those in the highest exposure category was 0.50 cl (95% CI -0.97 to 1.98) less than in the unexposed category. The corresponding figure for FEV1 was 0.89 cl (95% CI - 0.70 to 2.06). High exposure to insulation wool, asbestos, or silica, during the 12 months preceding the check up was associated with increased odds ratios (ORs) for persistent cough of the same magnitude as current smoking. CONCLUSIONS: The results indicate no effects on VC or FEV1 from exposure to insulation wool. Recent exposure to insulation wool, asbestos, and silica was associated with an increased prevalence of persistent cough.   PMID:9930086

  5. Air pollution and respiratory health among diabetic and non-diabetic subjects in Pune, India-results from the Wellcome Trust Genetic Study.

    PubMed

    Khafaie, Morteza Abdullatif; Salvi, Sundeep Santosh; Yajnik, Chittaranjan Sakerlal; Ojha, Ajay; Khafaie, Behzad; Gore, Sharad Damodar

    2017-06-01

    Diabetics may be more vulnerable to the harmful effects of ambient air pollutants than healthy individuals. But, the risk factors that lead to susceptibility to air pollution in diabetics have not yet been identified. We examined the effect of exposure to ambient PM 10 on chronic symptoms and the pulmonary function tests (PFT) in diabetic and non-diabetic subjects. Also, to investigate possible determinants of susceptibility, we recruited 400 type 2 diabetic and 465 healthy subjects who were investigated for chronic respiratory symptoms (CRSs) and then underwent measurement of forced vital capacity (FVC) and forced expiratory volume 1 (FEV1) according to standard protocol. Percent predicted FEV1 and FVC (FEV1% and FVC%, respectively) for each subject were calculated. Particulate matter (PM 10 ) concentrations at residence place of subjects were estimated using AERMOD dispersion model. The association between PM 10 and CRSs was explored using logistic regression. We also used linear regression models controlling for potential confounders to study the association between chronic exposure to PM 10 and FEV1% and FVC%. Prevalence of current wheezing, allergy symptom, chest tightness, FEV1/FVC <70%, and physician-diagnosed asthma and COPD was significantly higher among diabetic subjects than non-diabetics. There was no significant difference between percent predicted value of PFT among diabetic and non-diabetic subjects (P < 0.05). We estimated that 1 SD increase in PM 10 concentration was associated with a greater risk of having dyspnea by 1.50-fold (95% CI, 1.12-2.01). Higher exposure to PM 10 concentration was also significantly associated with lower FVC%. The size of effect for 1 SD μg/m 3 (=98.38) increase in PM 10 concentration was 3.71% (95% CI, 0.48-4.99) decrease in FVC%. In addition, we indicated that strength of these associations was higher in overweight, smoker, and aged persons. We demonstrated a possible contribution of air pollution to reduced lung function independent of diabetes status. This study suggests that decline in exposure may significantly reduce disease manifestation as dyspnea and impaired lung function. We conduct that higher BMI, smoking, and older age were associated with higher levels of air pollution effects.

  6. Lung Function in Rural Guatemalan Women Before and After a Chimney Stove Intervention to Reduce Wood Smoke Exposure: Results From the Randomized Exposure Study of Pollution Indoors and Respiratory Effects and Chronic Respiratory Effects of Early Childhood Exposure to Respirable Particulate Matter Study.

    PubMed

    Guarnieri, Michael; Diaz, Esperanza; Pope, Daniel; Eisen, Ellen A; Mann, Jennifer; Smith, Kirk R; Smith-Sivertsen, Tone; Bruce, Nigel G; Balmes, John R

    2015-11-01

    COPD is the third most frequent cause of death globally, with much of this burden attributable to household biomass smoke exposure in developing countries. As biomass smoke exposure is also associated with cardiovascular disease, lower respiratory infection, lung cancer, and cataracts, it presents an important target for public health intervention. Lung function in Guatemalan women exposed to wood smoke from open fires was measured throughout the Randomized Exposure Study of Pollution Indoors and Respiratory Effects (RESPIRE) stove intervention trial and continued during the Chronic Respiratory Effects of Early Childhood Exposure to Respirable Particulate Matter (CRECER) cohort study. In RESPIRE, early stove households received a chimney woodstove at the beginning of the 18-month trial, and delayed stove households received a stove at trial completion. Personal exposure to wood smoke was assessed with exhaled breath carbon monoxide (CO) and personal CO tubes. Change in lung function between intervention groups and as a function of wood smoke exposure was assessed using random effects models. Of 306 women participating in both studies, acceptable spirometry was collected in 129 early stove and 136 delayed stove households (n = 265), with a mean follow-up of 5.6 years. Despite reduced wood smoke exposures in early stove households, there were no significant differences in any of the measured spirometric variables during the study period (FEV1, FVC, FEV1/FVC ratio, and annual change) after adjustment for confounding. In these young Guatemalan women, there was no association between lung function and early randomization to a chimney stove or personal wood smoke exposure. Future stove intervention trials should incorporate cleaner stoves, longer follow-up, or potentially susceptible groups to identify meaningful differences in lung function.

  7. Airway obstruction related to diacetyl exposure at microwave popcorn production facilities.

    PubMed

    Lockey, J E; Hilbert, T J; Levin, L P; Ryan, P H; White, K L; Borton, E K; Rice, C H; McKay, R T; LeMasters, G K

    2009-07-01

    Obstructive lung diseases including bronchiolitis obliterans have been reported among microwave popcorn production employees. Butter flavourings including diacetyl have been associated with these findings. The present study was initiated at four microwave popcorn production plants to determine if exposure to diacetyl was associated with decrements in pulmonary function. Comprehensive diacetyl exposure assessment was undertaken for all job tasks. Spirometry was conducted for 765 full-time employees between 2005 and 2006. Outcomes included decrement in forced expiratory volume in one second (FEV(1)) % predicted, airway obstruction and persistent decline in FEV(1). Inclusion in the high-exposure group (mixers) prior to respirator use was associated with a significantly decreased FEV(1) % pred in non-Asian and Asian males at -6.1 and -11.8% pred, respectively, and an eight-fold increased risk for airway obstruction. Cumulative diacetyl exposure >or=0.8 ppm-yr caused similar results. No significant impact was seen in nonmixers or between current diacetyl exposure and persistent decline in FEV(1). Unprotected exposure as a mixer to butter flavouring including diacetyl resulted in decrements in FEV(1) (% pred) and increased airway obstruction. Control of employee exposure to butter flavouring additives is warranted in regard to both short-term peak and 8-h workday exposure.

  8. Clinical Use of Dornase Alfa Is Associated with a Slower Rate of FEV1 Decline in Cystic Fibrosis

    PubMed Central

    Konstan, Michael W.; Wagener, Jeffrey S.; Pasta, David J.; Millar, Stefanie J.; Jacobs, Joan R.; Yegin, Ashley; Morgan, Wayne J.

    2014-01-01

    SUMMARY Objectives Randomized controlled trials of dornase alfa have shown forced expiratory volume in 1 second (FEV1) to improve in patients with cystic fibrosis (CF) but have not assessed change in the rate of lung function decline. We assessed the relationship of dornase alfa use and FEV1 decline using the Epidemiologic Study of CF (ESCF). Methodology Patients aged 8–38 years who had been enrolled in ESCF for 2 years when initially treated with dornase alfa were selected if they remained on treatment during the following 2 years. A comparator group included patients aged 8–38 who were not yet reported to have received dornase alfa. For each patient we estimated the annual rate of decline in FEV1 % predicted before and after the index using a mixed-effects model adjusted for age, gender, pulmonary exacerbations, respiratory therapies, and nutritional supplements. Results The dornase alfa group (n = 2,230) had a lower FEV1 % predicted at index and a more rapid decline during the pre-index period. The mean rate of FEV1 decline improved for the dornase alfa group; the improvement was similar in adults and children 8–17 years old but was not statistically significant in adults. The comparator group (n = 5,970) showed no change among adults and an increased rate of decline among children 8–17 years old. Conclusions The use of dornase alfa for a 2-year period is associated with a reduction in the rate of FEV1 decline. These results also demonstrate the value of using an observational study to assess the association of instituting new therapies in the clinical setting with changes in the rate of FEV1 decline in patients with CF. PMID:21438174

  9. Chest circumference and birth weight are good predictors of lung function in preschool children from an e-waste recycling area.

    PubMed

    Zeng, Xiang; Xu, Xijin; Zhang, Yuling; Li, Weiqiu; Huo, Xia

    2017-10-01

    The purpose of this study was to investigate the associations between birth weight, chest circumference, and lung function in preschool children from e-waste exposure area. A total of 206 preschool children from Guiyu (an e-waste recycling area) and Haojiang and Xiashan (the reference areas) in China were recruited and required to undergo physical examination, blood tests, and lung function tests during the study period. Birth outcome such as birth weight and birth height were obtained by questionnaire. Children living in the e-waste-exposed area have a lower birth weight, chest circumference, height, and lung function when compare to their peers from the reference areas (all p value <0.05). Both Spearman and partial correlation analyses showed that birth weight and chest circumference were positively correlated with lung function levels including forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV 1 ). After adjustment for the potential confounders in further linear regression analyses, birth weight, and chest circumference were positively associated with lung function levels, respectively. Taken together, birth weight and chest circumference may be good predictors for lung function levels in preschool children.

  10. Challenges in Collating Spirometry Reference Data for South-Asian Children: An Observational Study.

    PubMed

    Lum, Sooky; Bountziouka, Vassiliki; Quanjer, Philip; Sonnappa, Samatha; Wade, Angela; Beardsmore, Caroline; Chhabra, Sunil K; Chudasama, Rajesh K; Cook, Derek G; Harding, Seeromanie; Kuehni, Claudia E; Prasad, K V V; Whincup, Peter H; Lee, Simon; Stocks, Janet

    2016-01-01

    Spirometry datasets from South-Asian children were collated from four centres in India and five within the UK. Records with transcription errors, missing values for height or spirometry, and implausible values were excluded(n = 110). Following exclusions, cross-sectional data were available from 8,124 children (56.3% male; 5-17 years). When compared with GLI-predicted values from White Europeans, forced expired volume in 1s (FEV1) and forced vital capacity (FVC) in South-Asian children were on average 15% lower, ranging from 4-19% between centres. By contrast, proportional reductions in FEV1 and FVC within all but two datasets meant that the FEV1/FVC ratio remained independent of ethnicity. The 'GLI-Other' equation fitted data from North India reasonably well while 'GLI-Black' equations provided a better approximation for South-Asian data than the 'GLI-White' equation. However, marked discrepancies in the mean lung function z-scores between centres especially when examined according to socio-economic conditions precluded derivation of a single South-Asian GLI-adjustment. Until improved and more robust prediction equations can be derived, we recommend the use of 'GLI-Black' equations for interpreting most South-Asian data, although 'GLI-Other' may be more appropriate for North Indian data. Prospective data collection using standardised protocols to explore potential sources of variation due to socio-economic circumstances, secular changes in growth/predictors of lung function and ethnicities within the South-Asian classification are urgently required.

  11. Lung function parameters improve prediction of VO2peak in an elderly population: The Generation 100 study.

    PubMed

    Hassel, Erlend; Stensvold, Dorthe; Halvorsen, Thomas; Wisløff, Ulrik; Langhammer, Arnulf; Steinshamn, Sigurd

    2017-01-01

    Peak oxygen uptake (VO2peak) is an indicator of cardiovascular health and a useful tool for risk stratification. Direct measurement of VO2peak is resource-demanding and may be contraindicated. There exist several non-exercise models to estimate VO2peak that utilize easily obtainable health parameters, but none of them includes lung function measures or hemoglobin concentrations. We aimed to test whether addition of these parameters could improve prediction of VO2peak compared to an established model that includes age, waist circumference, self-reported physical activity and resting heart rate. We included 1431 subjects aged 69-77 years that completed a laboratory test of VO2peak, spirometry, and a gas diffusion test. Prediction models for VO2peak were developed with multiple linear regression, and goodness of fit was evaluated. Forced expiratory volume in one second (FEV1), diffusing capacity of the lung for carbon monoxide and blood hemoglobin concentration significantly improved the ability of the established model to predict VO2peak. The explained variance of the model increased from 31% to 48% for men and from 32% to 38% for women (p<0.001). FEV1, diffusing capacity of the lungs for carbon monoxide and hemoglobin concentration substantially improved the accuracy of VO2peak prediction when added to an established model in an elderly population.

  12. Association between neutrophilic airway inflammation and airflow limitation in adults with asthma.

    PubMed

    Shaw, Dominick E; Berry, Michael A; Hargadon, Bev; McKenna, Susan; Shelley, Maria J; Green, Ruth H; Brightling, Christopher E; Wardlaw, Andrew J; Pavord, Ian D

    2007-12-01

    There is debate about the mechanisms of persistent airflow limitation in patients with asthma. Chronic inflammation is assumed to be important, although there is limited and contradictory information about the relationship between airway inflammation and postbronchodilator FEV1. We have assessed the cross-sectional relationship between prebronchodilator and postbronchodilator FEV1 and measures of airway inflammation after allowing for the effects of potential confounding factors. Multivariate analysis was performed on data collected from 1,197 consecutive patients with asthma seen at the respiratory outpatient clinic at Glenfield Hospital between 1997 and 2004. Relationships between induced sputum total neutrophil and differential eosinophil cell counts, and prebronchodilator and postbronchodilator lung function were examined. Sputum total neutrophil but not differential eosinophil count was associated with lower postbronchodilator FEV1. Both differential eosinophil and total neutrophil count were associated with lower prebronchodilator FEV1. These effects were independent after adjustment for age, smoking, ethnicity, asthma duration, and inhaled corticosteroid use. A 10-fold increase in neutrophil count was associated with a 92 mL reduction (95% confidence interval, 29 to 158; p = 0.007) in postbronchodilator FEV1. In this large heterogeneous population of adults with asthma, we have shown that prebronchodilator FEV1 is associated with neutrophilic and eosinophilic airway inflammation, whereas sputum total neutrophil counts alone are associated with postbronchodilator FEV1. This supports the hypothesis that neutrophilic airway inflammation has a role in the progression of persistent airflow limitation in asthma and raises the possibility that this progression and the development of COPD share a common mechanism.

  13. Roflumilast in moderate-to-severe chronic obstructive pulmonary disease treated with longacting bronchodilators: two randomised clinical trials.

    PubMed

    Fabbri, Leonardo M; Calverley, Peter M A; Izquierdo-Alonso, José Luis; Bundschuh, Daniela S; Brose, Manja; Martinez, Fernando J; Rabe, Klaus F

    2009-08-29

    Patients with chronic obstructive pulmonary disease (COPD) have few options for treatment. The efficacy and safety of the phosphodiesterase-4 inhibitor roflumilast have been investigated in studies of patients with moderate-to-severe COPD, but not in those concomitantly treated with longacting inhaled bronchodilators. The effect of roflumilast on lung function in patients with COPD that is moderate to severe who are already being treated with salmeterol or tiotropium was investigated. In two double-blind, multicentre studies done in an outpatient setting, after a 4-week run-in, patients older than 40 years with moderate-to-severe COPD were randomly assigned to oral roflumilast 500 microg or placebo once a day for 24 weeks, in addition to salmeterol (M2-127 study) or tiotropium (M2-128 study). The primary endpoint was change in prebronchodilator forced expiratory volume in 1 s (FEV(1)). Analysis was by intention to treat. The studies are registered with ClinicalTrials.gov, number NCT00313209 for M2-127, and NCT00424268 for M2-128. In the salmeterol plus roflumilast trial, 466 patients were assigned to and treated with roflumilast and 467 with placebo; in the tiotropium plus roflumilast trial, 371 patients were assigned to and treated with roflumilast and 372 with placebo. Compared with placebo, roflumilast consistently improved mean prebronchodilator FEV(1) by 49 mL (p<0.0001) in patients treated with salmeterol, and 80 mL (p<0.0001) in those treated with tiotropium. Similar improvement in postbronchodilator FEV(1) was noted in both groups. Furthermore, roflumilast had beneficial effects on other lung function measurements and on selected patient-reported outcomes in both groups. Nausea, diarrhoea, weight loss, and, to a lesser extent, headache were more frequent in patients in the roflumilast groups. These adverse events were associated with increased patient withdrawal. Roflumilast improves lung function in patients with COPD treated with salmeterol or tiotropium, and could become an important treatment for these patients. Nycomed.

  14. Respiratory symptoms and lung functional impairments associated with occupational exposure to asphalt fumes.

    PubMed

    Neghab, M; Zare Derisi, F; Hassanzadeh, J

    2015-04-01

    Controversy exists as to the potential of asphalt fumes to induce respiratory symptoms and lung functional impairments. To examine the respiratory effects, if any, of occupational inhalation exposure to asphalt fumes. In this cross-sectional study, 74 asphalt workers and 110 unexposed employees were investigated. The prevalence of respiratory symptoms among subjects was investigated by a standard questionnaire. Additionally, the parameters of pulmonary function were measured both, prior to exposure and at the end of work-shift. Furthermore, to assess the extent to which workers were exposed to asphalt fumes, total particulate and the benzene-soluble fraction were measured in different worksites. The mean levels of exposure to total particulate and benzene-soluble fraction in asphalt fumes were estimated to be 0.9 (SD 0.2) and 0.3 (SD 0.1) mg/m^3, respectively. Mean values of FEV1, both prior to the exposure (89.58% [SD 18.69%] predicted value) and at the end of shift (85.38% [SD 19.4%]), were significantly (p<0.05) smaller than those of the comparison subjects (93.88% [SD 13.93%]). Similarly, pre-shift (87.05 [SD 8.57]) and postexposure (89.95 [SD 6.85]) FEV1/FVC ratio were both significantly (p<0.01) lower than those of the unexposed employees (107.56 [SD 9.64]). Moreover, the prevalence of respiratory symptoms such as cough and wheezing in exposed employees were 41% and 42%, respectively. The corresponding values for comparison subjects were 10.0% and 3.6%, respectively (p<0.001). The pattern of changes in parameters of lung function in asphalt workers was consistent with that of chronic obstructive lung disease. Significant decrements in the parameters of pulmonary function as well as, a significant increase in the prevalence of respiratory symptoms in asphalt paving workers compared to their unexposed counterparts provided evidence in favor of a significant association between exposure to asphalt fumes and lung function impairments.

  15. Morbidity, mortality, and categorization of the risk of perioperative complications in lung cancer patients*

    PubMed Central

    Stanzani, Fabiana; Paisani, Denise de Moraes; de Oliveira, Anderson; de Souza, Rodrigo Caetano; Perfeito, João Aléssio Juliano; Faresin, Sonia Maria

    2014-01-01

    OBJECTIVE: To determine morbidity and mortality rates by risk category in accordance with the American College of Chest Physicians guidelines, to determine what role pulmonary function tests play in this categorization process, and to identify risk factors for perioperative complications (PCs). METHODS: This was a historical cohort study based on preoperative and postoperative data collected for cases of lung cancer diagnosed or suspected between 2001 and 2010. RESULTS: Of the 239 patients evaluated, only 13 (5.4%) were classified as being at high risk of PCs. Predicted postoperative FEV1 (FEV1ppo) was sufficient to define the risk level in 156 patients (65.3%); however, cardiopulmonary exercise testing (CPET) was necessary for identifying those at high risk. Lung resection was performed in 145 patients. Overall morbidity and mortality rates were similar to those reported in other studies. However, morbidity and mortality rates for patients at an acceptable risk of PCs were 31.6% and 4.3%, respectively, whereas those for patients at high risk were 83.3% and 33.3%. Advanced age, COPD, lobe resection, and lower FEV1ppo were correlated with PCs. CONCLUSIONS: Although spirometry was sufficient for risk assessment in the majority of the population studied, CPET played a key role in the identification of high-risk patients, among whom the mortality rate was seven times higher than was that observed for those at an acceptable risk of PCs. The risk factors related to PCs coincided with those reported in previous studies. PMID:24626266

  16. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water

    PubMed Central

    Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel

    2017-01-01

    ABSTRACT Objective: To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. Methods: This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. Results: We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. Conclusions: When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile. PMID:29340488

  17. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water.

    PubMed

    Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel

    2017-01-01

    To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.

  18. Serum insulin-like growth factor-1 (IGF-1) during CF pulmonary exacerbation: trends and biomarker correlations.

    PubMed

    Gifford, A H; Nymon, A B; Ashare, A

    2014-04-01

    Cystic fibrosis (CF) is characterized by low circulating levels of insulin-like growth factor-1 (IGF-1), a hormone produced by the liver that governs anabolism and influences immune cell function. Because treatment of CF pulmonary exacerbation (CFPE) often improves body weight and lung function, we questioned whether serum IGF-1 trends were emblematic of these responses. Initially, we compared serum levels between healthy adults with CF and controls of similar age. We then measured serum IGF-1 throughout the CFPE cycle. We also investigated correlations among IGF-1 and other serum biomarkers during CFPE. Anthopometric, spirometric, and demographic data were collected. Serum IGF-1 concentrations were measured by ELISA. CF subjects in their usual state of health had lower serum IGF-1 levels than controls. Serum IGF-1 concentrations fell significantly from baseline at the beginning of CFPE. Treatment with intravenous antibiotics was associated with significant improvement in serum IGF-1 levels, body mass index (BMI), and percent-predicted forced expiratory volume in 1 sec (FEV1 %). At early and late CFPE, serum IGF-1 was directly correlated with FEV1 %, serum iron, hemoglobin concentration, and transferrin saturation (TSAT) and indirectly correlated with alpha-1-antitrypsin. This study not only supports the paradigm that CF is characterized by IGF-1 deficiency but also that trends in lung function, nutritional status, and serum IGF-1 are related. Improvements in all three parameters after antibiotics for CFPE likely highlight the connection between lung function and nutritional status in CF. Close correlations among IGF-1 and iron-related hematologic parameters suggest that IGF-1 may participate in CF iron homeostasis, another process that is known to be influenced by CFPE. © 2013 Wiley Periodicals, Inc.

  19. Pulmonary function abnormalities in never-smoking flight attendants exposed to secondhand tobacco smoke in the aircraft cabin.

    PubMed

    Arjomandi, Mehrdad; Haight, Thaddeus; Redberg, Rita; Gold, Warren M

    2009-06-01

    To determine whether the flight attendants who were exposed to secondhand tobacco smoke in the aircraft cabin have abnormal pulmonary function. We administered questionnaires and performed pulmonary function testing in 61 never-smoking female flight attendants who worked in active air crews before the smoking ban on commercial aircraft (preban). Although the preban flight attendants had normal FVC, FEV1, and FEV1/FVC ratio, they had significantly decreased flow at mid- and low-lung volumes, curvilinear flow-volume curves, and evidence of air trapping. Furthermore, the flight attendants had significantly decreased diffusing capacity (77.5% +/- 11.2% predicted normal) with 51% having a diffusing capacity below their 95% normal prediction limit. This cohort of healthy never-smoking flight attendants who were exposed to secondhand tobacco smoke in the aircraft cabin showed pulmonary function abnormalities suggestive of airway obstruction and impaired diffusion.

  20. Biomarkers for Pulmonary Inflammation and Fibrosis and Lung Ventilation Function in Chinese Occupational Refractory Ceramic Fibers-Exposed Workers

    PubMed Central

    Gu, Yishuo; Ma, Wenjun; Gao, Panjun; Liu, Mengxuan; Xiao, Pei; Wang, Hongfei; Chen, Juan; Li, Tao

    2017-01-01

    Refractory ceramic fibers (RCFs) can cause adverse health effects on workers’ respiratory system, yet no proper biomarkers have been used to detect early pulmonary injury of RCFs-exposed workers. This study assessed the levels of two biomarkers that are related to respiratory injury in RCFs-exposed workers, and explored their relations with lung function. The exposure levels of total dust and respirable fibers were measured simultaneously in RCFs factories. The levels of TGF-β1 and ceruloplasmin (CP) increased with the RCFs exposure level (p < 0.05), and significantly increased in workers with high exposure level (1.21 ± 0.49 ng/mL, 115.25 ± 32.44 U/L) when compared with the control group (0.99 ± 0.29 ng/mL, 97.90 ± 35.01 U/L) (p < 0.05). The levels of FVC and FEV1 were significantly decreased in RCFs exposure group (p < 0.05). Negative relations were found between the concentrations of CP and FVC (B = −0.423, p = 0.025), or FEV1 (B = −0.494, p = 0.014). The concentration of TGF-β1 (B = 0.103, p = 0.001) and CP (B = 8.027, p = 0.007) were associated with respirable fiber exposure level. Occupational exposure to RCFs can impair lung ventilation function and may have the potential to cause pulmonary inflammation and fibrosis. TGF-β1 and CP might be used as sensitive and noninvasive biomarkers to detect lung injury in occupational RCFs-exposed workers. Respirable fiber concentration can better reflect occupational RCFs exposure and related respiratory injuries. PMID:29280967

  1. The association of exposure to hepatitis B and C viruses with lung function and respiratory disease: a population based study from the NHANES III database.

    PubMed

    Goh, Li Yen; Card, Tim; Fogarty, Andrew W; McKeever, Tricia M

    2014-12-01

    Globally, 500 million people are chronically infected with Hepatitis B virus (HBV) and Hepatitis C virus (HCV). While these viruses are notorious for their detrimental effect on the liver they are also known to affect multiple organs in the body including the lungs. To investigate if exposure to HBV and HCV is associated with lung function and respiratory diseases. Data from the Third National Health and Nutrition Examination Survey (NHANES III) was analysed using multiple linear regressions to investigate the association between exposure to HBV and HCV with the various measures of lung function, while multiple logistic regressions were used to evaluate the association with the respiratory diseases asthma and chronic obstructive pulmonary disease (COPD). Exposure to HCV was significantly associated with an increase in Forced Expiratory Volume in 1 s, FEV1 (Coef: 97.94 ml, 95% CI: 38.87 to 157.01) and Full Vital Capacity, FVC (Coef: 90 ml, 95% CI: 14.50 to 166.24). Individuals who had been exposed to both HBV and HCV also had a significantly higher FEV1 (Coef: 145.82, CI: 60.68 to 230.94) and FVC (Coef: 195.09, CI: 78.91 to 311.26). There was also a significant association between exposure to HBV and asthma (OR: 1.28, 95% CI: 1.05 to 1.58). These associations were no longer significant after additionally adjusting for cocaine and marijuana use as well as poverty income ratio. Our research implies that hepatotropic viruses may affect the respiratory system, but more work at a population level is needed to further explore these associations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Declining Pulmonary Function in Populations with Long-term Exposure to Polycyclic Aromatic Hydrocarbons-Enriched PM2.5.

    PubMed

    Shen, Meili; Xing, Jie; Ji, Qianpeng; Li, Zhihui; Wang, Yanhua; Zhao, Hongwei; Wang, Qingrong; Wang, Ting; Yu, Liwei; Zhang, Xiuchuan; Sun, Yaxin; Zhang, Zhihu; Niu, Yong; Wang, Huanqiang; Chen, Wen; Dai, Yufei; Su, Wenge; Duan, Huawei

    2018-06-05

    This study assesses the effects of long-term exposure to ambient air pollutants on inflammatory response and lung function. We selected 390 male coke oven workers with exposure to polycyclic aromatic hydrocarbons (PAHs) and fine particulate matter (PM 2.5 ) and 115 control workers. The average duration in the exposed group was 9.10 years. The total amount of PAHs was more enriched in PM 2.5 which collected from the coke oven workshops compared with the control areas. Correspondingly, the internal PAHs exposure indicated by urinary 1-hydroxypyrene (1-OHP) in the exposure group increased 25.7-fold compared to that of the control group. Moreover, the increasing level of urinary 1-OHP was associated with the decrease of forced expiratory volume in 1 s to forced vital capacity ratio (FEV 1 /FVC). In non-current smokers of exposure group, inverse correlation of 1-OHP with FEV 1 /FVC was also found. Particularly, an exposure duration-dependent decline in FEV 1 /FVC and mean forced expiratory flow between 25% and 75% of forced vital capacity (FEF 25-75% ) indicated that small airways were functionally obstructed. Furthermore, the increasing serum high-sensitivity C-reactive protein (hs-CRP) was correlated with the decline in pulmonary function in all subjects. These findings provide a clue that long-term exposure to PAHs-enriched PM 2.5 impairs pulmonary function in occupational population.

  3. Air pollution, airway inflammation, and lung function in a cohort study of Mexico City schoolchildren.

    PubMed

    Barraza-Villarreal, Albino; Sunyer, Jordi; Hernandez-Cadena, Leticia; Escamilla-Nuñez, Maria Consuelo; Sienra-Monge, Juan Jose; Ramírez-Aguilar, Matiana; Cortez-Lugo, Marlene; Holguin, Fernando; Diaz-Sánchez, David; Olin, Anna Carin; Romieu, Isabelle

    2008-06-01

    The biological mechanisms involved in inflammatory response to air pollution are not clearly understood. In this study we assessed the association of short-term air pollutant exposure with inflammatory markers and lung function. We studied a cohort of 158 asthmatic and 50 nonasthmatic school-age children, followed an average of 22 weeks. We conducted spirometric tests, measurements of fractional exhaled nitric oxide (Fe(NO)), interleukin-8 (IL-8) in nasal lavage, and pH of exhaled breath condensate every 15 days during follow-up. Data were analyzed using linear mixed-effects models. An increase of 17.5 microg/m(3) in the 8-hr moving average of PM(2.5) levels (interquartile range) was associated with a 1.08-ppb increase in Fe(NO) [95% confidence interval (CI), 1.01-1.16] and a 1.07-pg/mL increase in IL-8 (95% CI 0.98-1.19) in asthmatic children and a 1.16 pg/ml increase in IL-8 (95% CI, 1.00-1.36) in nonasthmatic children. The 5-day accumulated average of exposure to particulate matter <2.5 microm in aerodynamic diamter (PM(2.5)) was significantly inversely associated with forced expiratory volume in 1 sec (FEV(1)) (p=0.048) and forced vital capacity (FVC) (p=0.012) in asthmatic children and with FVC (p=0.021) in nonasthmatic children. Fe(NO) and FEV(1) were inversely associated (p=0.005) in asthmatic children. Exposure to PM(2.5) resulted in acute airway inflammation and decrease in lung function in both asthmatic and nonasthmatic children.

  4. Myelodysplastic syndrome patients present more severe respiratory muscle impairment and reduced forced vital capacity: Is disordered inflammatory signaling the culprit?

    PubMed

    Okubo, Bruno Memória; Matos, Anacélia Gomes de; Ribeiro Junior, Howard Lopes; Borges, Daniela de Paula; Oliveira, Roberta Taiane Germano de; de Castro, Marilena Facundo; Martins, Manoel Ricardo Alves; Gonçalves, Romélia Pinheiro; Bruin, Pedro Felipe Carvalhedo; Pinheiro, Ronald Feitosa; Magalhães, Silvia Maria Meira

    2017-01-01

    The ageing process is associated with gradual decline in respiratory system performance. Anemia is highly prevalent among older adults and usually associated with adverse outcomes. Myelodysplastic syndromes (MDS) are a heterogeneous group of hematologic malignancies with increasing incidence with age and characterized by anemia and other cytopenias. The main objectives of this study were to evaluate respiratory muscle strength and lung function in elderly patients with anemia, compare data between myelodysplastic syndromes and non-clonal anemias and evaluate the influence of serum IL-8 level and NF-kB activity on deteriorate pulmonary function in this specific population. Individuals aged 60 and older with anemia secondary to MDS, non-clonal anemia and healthy elderly individuals. Forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), and FEV1/ FVC ratio were measured by spirometry. Respiratory muscle strength was evaluated by maximal static respiratory pressures measurement. IL-8 analysis was performed by ELISA and activity of NF-kB by chemiluminescent assay. Mean Hb concentration was comparable between patients with anemia. Significant differences were detected between all patients with anemia and controls for maximum-effort inspiratory mouth pressure (PImax) and also for maximum-effort expiratory mouth pressure (PEmax). The MDS group recorded a significantly lower PImax and PEmax percent predicted when compared to non-clonal anemia group. For FVC and FEV1, a significant difference was found in anemic patients, with even significantly lower values for FVC and FEV1 in MDS group. No significant differences were detected for PImax and PEmax and spirometry parameters when anemic patients were stratified according to the degree of anemia. A significant negative impact in FVC (% pred), PImax (% pred) and PEmax (% pred) was observed in patients with MDS and higher levels of IL-8 or increased activity of NF-kB. A negative impact of anemia, independent of its degree, was demonstrated in respiratory muscle strength and lung function particularly in MDS. The well known elevated proinflammatory cytokines in MDS patients were proposed to play a role as was demonstrated by detrimental effect of higher IL-8 and NF-kB in pulmonary function tests in this population.

  5. Aspergillus/allergic bronchopulmonary aspergillosis in an Irish cystic fibrosis population: a diagnostically challenging entity.

    PubMed

    Chotirmall, Sanjay Haresh; Branagan, Peter; Gunaratnam, Cedric; McElvaney, Noel Gerard

    2008-08-01

    Patients with cystic fibrosis (CF) can become colonized by aspergillus, which can act as an allergen and cause allergic bronchopulmonary aspergillosis (ABPA). To determine the rate of aspergillus colonization and ABPA in a population of Irish patients with CF. In 50 consecutive patients with CF who presented with exacerbations, we looked for the presence of aspergillus in their sputum and signs and symptoms of ABPA. Fifteen patients (30%) grew aspergillus species in their sputum cultures. Six patients (12%) had ABPA. Matched for age, sex, genotype, and microbiology, there was no significant difference in forced expiratory volume in the first second (percent predicted, FEV(1)%) in subjects with aspergillus-positive sputum compared to those not colonized with aspergillus. Subjects with ABPA experienced sharp short-term deterioration in lung function (mean 6.7% predicted FEV(1)), which returned to baseline following at least 4 weeks of treatment. The prevalence of ABPA was 12%. Aspergillus-positive sputum of itself was not a poor prognostic sign in terms of lung function over the 5-year study course. ABPA produces short-term reversible declines in lung function and responds to treatment. The frequency of aspergillus isolates did not correlate with the occurrence of ABPA. A low threshold for the diagnosis of ABPA should be maintained in any patient with CF who does not improve with antibiotics.

  6. [Effect of the components of the metabolic syndrome on pulmonary function. The unexpected role of high-density lipoprotein cholesterol].

    PubMed

    Huerta-Ramírez, Saúl; Paniagua-Pérez, Angélica; Castro-Serna, David; Ledesma-Velázquez, Andrés; Rubio-Guerra, Alberto; Vargas-Ayala, Germán

    2018-01-01

    Metabolic syndrome is a condition that predisposes to cardiovascular disease and diabetes mellitus. In addition, it can have effects over neoplastic pathologies, liver and pulmonary function. Our objective is to analyze the effect of the metabolic syndrome and its components on pulmonary function. 110 subjects from Mexico City were evaluated and anthropometric measurements, glucose determination, triglycerides and high-density lipoprotein (HDL) cholesterol were made. They underwent a simple spirometry. Diagnosis of metabolic syndrome was made following the NCEP-ATPIII criteria. Of 110 individuals, 90 (82%) were women and 20 men (18%); 71 subjects (65%) presented metabolic syndrome. Subjects with central obesity had a forced vital capacity (FVC) lower than subjects without central obesity (2.72 vs. 3.11 liters; p < 0.05). Those with low HDL had better spirometric results than subjects with normal HDL (FEV1 2.36 vs. 1.85 liters; p < 0.05), FVC (2.95 vs. 2.45 liters; p < 0.05) and FEV1/FVC ratio (0.78 vs.74; p < 0.05). Hypertensive subjects presented lower volumes in FEV1 (1.91 vs. 2.38; p < 0.05) and FVC (2.49 vs. 2.99; p < 0.05). There is no difference between the spirometry volumes of patients with metabolic syndrome versus the metabolically healthy subjects. The only factors associated with a decrease in FEV1 and FVC are central obesity and arterial hypertension. An unexpected finding was the negative correlation between HDL levels and lung function. Copyright: © 2018 Permanyer.

  7. Connective tissue-activating peptide III: a novel blood biomarker for early lung cancer detection.

    PubMed

    Yee, John; Sadar, Marianne D; Sin, Don D; Kuzyk, Michael; Xing, Li; Kondra, Jennifer; McWilliams, Annette; Man, S F Paul; Lam, Stephen

    2009-06-10

    There are no reliable blood biomarkers to detect early lung cancer. We used a novel strategy that allows discovery of differentially present proteins against a complex and variable background. Mass spectrometry analyses of paired pulmonary venous-radial arterial blood from 16 lung cancer patients were applied to identify plasma proteins potentially derived from the tumor microenvironment. Two differentially expressed proteins were confirmed in 64 paired venous-arterial blood samples using an immunoassay. Twenty-eight pre- and postsurgical resection peripheral blood samples and two independent, blinded sets of plasma from 149 participants in a lung cancer screening study (49 lung cancers and 100 controls) and 266 participants from the National Heart Lung and Blood Institute Lung Health Study (45 lung cancer and 221 matched controls) determined the accuracy of the two protein markers to detect subclinical lung cancer. Connective tissue-activating peptide III (CTAP III)/ neutrophil activating protein-2 (NAP-2) and haptoglobin were identified to be significantly higher in venous than in arterial blood. CTAP III/NAP-2 levels decreased after tumor resection (P = .01). In two independent population cohorts, CTAP III/NAP-2 was significantly associated with lung cancer and improved the accuracy of a lung cancer risk prediction model that included age, smoking, lung function (FEV(1)), and an interaction term between FEV(1) and CTAP III/NAP-2 (area under the curve, 0.84; 95% CI, 0.77 to 0.91) compared to CAPIII/NAP-2 alone. We identified CTAP III/NAP-2 as a novel biomarker to detect preclinical lung cancer. The study underscores the importance of applying blood biomarkers as part of a multimodal lung cancer risk prediction model instead of as stand-alone tests.

  8. Respiratory symptoms and lung function in relation to wood dust and monoterpene exposure in the wood pellet industry.

    PubMed

    Löfstedt, Håkan; Hagström, Katja; Bryngelsson, Ing-Liss; Holmström, Mats; Rask-Andersen, Anna

    2017-06-01

    Wood pellets are used as a source of renewable energy for heating purposes. Common exposures are wood dust and monoterpenes, which are known to be hazardous for the airways. The purpose of this study was to study the effect of occupational exposure on respiratory health in wood pellet workers. Thirty-nine men working with wood pellet production at six plants were investigated with a questionnaire, medical examination, allergy screening, spirometry, and nasal peak expiratory flow (nasal PEF). Exposure to wood dust and monoterpenes was measured. The wood pellet workers reported a higher frequency of nasal symptoms, dry cough, and asthma medication compared to controls from the general population. There were no differences in nasal PEF between work and leisure time. A lower lung function than expected (vital capacity [VC], 95%; forced vital capacity in 1 second [FEV 1 ], 96% of predicted) was noted, but no changes were noted during shifts. There was no correlation between lung function and years working in pellet production. Personal measurements of wood dust at work showed high concentrations (0.16-19 mg/m 3 ), and exposure peaks when performing certain work tasks. Levels of monoterpenes were low (0.64-28 mg/m 3 ). There was no association between exposure and acute lung function effects. In this study of wood pellet workers, high levels of wood dust were observed, and that may have influenced the airways negatively as the study group reported upper airway symptoms and dry cough more frequently than expected. The wood pellet workers had both a lower VC and FEV 1 than expected. No cross-shift changes were found.

  9. Association of dietary soy genistein intake with lung function and asthma control: a post-hoc analysis of patients enrolled in a prospective multicentre clinical trial

    PubMed Central

    Bime, Christian; Wei, Christine Y; Holbrook, Janet; Smith, Lewis J; Wise, Robert A

    2013-01-01

    Background Broad dietary patterns have been linked to asthma but the relative contribution of specific nutrients is unclear. Soy genistein has important anti-inflammatory and other biological effects that might be beneficial in asthma. A positive association was previously reported between soy genistein intake and lung function but not with asthma exacerbations. Aims To conduct a post-hoc analysis of patients with inadequately controlled asthma enrolled in a prospective multicentre clinical trial to replicate this association. Methods A total of 300 study participants were included in the analysis. Dietary soy genistein intake was measured using the Block Soy Foods Screener. The level of soy genistein intake (little or no intake, moderate intake, or high intake) was compared with baseline lung function (pre-bronchodilator forced expiratory volume in 1 second (FEV1)) and asthma control (proportion of participants with an episode of poor asthma control (EPAC) and annualised rates of EPACs over a 6-month follow-up period. Results Participants with little or no genistein intake had a lower baseline FEV1 than those with a moderate or high intake (2.26L vs. 2.53L and 2.47L, respectively; p=0.01). EPACs were more common among those with no genistein intake than in those with a moderate or high intake (54% vs. 35% vs. 40%, respectively; p<0.001). These findings remained significant after adjustment for patient demographics and body mass index. Conclusions In patients with asthma, consumption of a diet with moderate to high amounts of soy genistein is associated with better lung function and better asthma control. PMID:22885561

  10. Respiratory symptoms and lung function in relation to wood dust and monoterpene exposure in the wood pellet industry

    PubMed Central

    Löfstedt, Håkan; Hagström, Katja; Bryngelsson, Ing-Liss; Holmström, Mats; Rask-Andersen, Anna

    2017-01-01

    Introduction Wood pellets are used as a source of renewable energy for heating purposes. Common exposures are wood dust and monoterpenes, which are known to be hazardous for the airways. The purpose of this study was to study the effect of occupational exposure on respiratory health in wood pellet workers. Materials and methods Thirty-nine men working with wood pellet production at six plants were investigated with a questionnaire, medical examination, allergy screening, spirometry, and nasal peak expiratory flow (nasal PEF). Exposure to wood dust and monoterpenes was measured. Results The wood pellet workers reported a higher frequency of nasal symptoms, dry cough, and asthma medication compared to controls from the general population. There were no differences in nasal PEF between work and leisure time. A lower lung function than expected (vital capacity [VC], 95%; forced vital capacity in 1 second [FEV1], 96% of predicted) was noted, but no changes were noted during shifts. There was no correlation between lung function and years working in pellet production. Personal measurements of wood dust at work showed high concentrations (0.16–19 mg/m3), and exposure peaks when performing certain work tasks. Levels of monoterpenes were low (0.64–28 mg/m3). There was no association between exposure and acute lung function effects. Conclusions In this study of wood pellet workers, high levels of wood dust were observed, and that may have influenced the airways negatively as the study group reported upper airway symptoms and dry cough more frequently than expected. The wood pellet workers had both a lower VC and FEV1 than expected. No cross-shift changes were found. PMID:28276782

  11. [Preliminary study of clinical significance of decreased D(L)CO in patients with left ventricular heart failure].

    PubMed

    Tan, Xiao-yue; Sun, Xing-guo; Hu, Sheng-shou; Zhang, Jian; Huang, Jie; Chen, Zhi-gao; Ma, Li

    2015-07-01

    This study aimed to investigate the feature of D(L)CO (Diffusion Lung Capacity for Carbon Monoxide) in CHF (left ventricular heart failure) patients, underlying pathophysiological mechanism and clinical significance. We retrospectively studied the D(L)CO, pulmonary ventilation function, cardiopulmonary exercise testing and related clinical information in severer HF patients. Peak VO2 severely decreased to 34 ± 7 percentage of predicted(%pred) and anaerobic threshold to 48 ± 11%pred in all patients. D(L)CO moderately decreased to 63 ± 12%pred and there were 25 patients lower than 80%pred. FVC, FEV1, FEV1/FVC and TLC were 75 ± 14%pred, 71 ± 17%pred, 97 ± 11%pred, and 79 ± 13%pred, which indicated borderline or mild restrictive ventilatory dysfunction. The decrease of D(L)CO was more severe than those of TLC, FEV1 and FVC. For patients with severe CHF, cardiopulmonary exercise function is extremely limited, D(L)CO generally moderately declines and ventilation function is merely mildly limited. D(L)CO is the parameter for cardiopulmonary coupling, reflecting limitation of the cardiovascular dysfunction while without ventilatory limit.

  12. Work related decrement in pulmonary function in silicon carbide production workers.

    PubMed Central

    Osterman, J W; Greaves, I A; Smith, T J; Hammond, S K; Robins, J M; Thériault, G

    1989-01-01

    The relation between pulmonary function, cigarette smoking, and exposure to mixed respirable dust containing silicon carbide (SiC), hydrocarbons, and small quantities of quartz, cristobalite, and graphite was evaluated in 156SiC production workers using linear regression models on the difference between measured and predicted FEV1 and FVC. Workers had an average of 16 (range 2-41) years of employment and 9.5 (range 0.6-39.7) mg-year/m3 cumulative respirable dust exposure; average dust exposure while employed was 0.63 (range 0.18-1.42) mg/m3. Occasional, low level (less than or equal to 1.5 ppm) sulphur dioxide (SO2) exposure also occurred. Significant decrements in FEV1 (8.2 ml; p less than 0.03) and FVC (9.4 ml; p less than 0.01) were related to each year of employment for the entire group. Never smokers lost 17.8 ml (p less than 0.02) of FEV1 and 17.0 (p less than 0.05) of FVC a year, whereas corresponding decrements of 9.1 ml (p = 0.12) in FEV1 and 14.4 ml (p less than 0.02) in FVC were found in current smokers. Similar losses in FEV1 and FVC were related to each mg-year/m3 of cumulative dust exposure for 138 workers with complete exposure information; these findings, however, were generally not significant owing to the smaller cohort and greater variability in this exposure measure. Never smokers had large decrements in FEV1 (40.7 ml; p less than 0.02) and FVC (32.9 ml; p = 0.08) per mg-year/m3 of cumulative dust exposure and non-significant decrements were found in current smokers (FEV1: -7.1 ml; FVC: -11.7 ml). A non-significant decrement in lung function was also related to average dust exposure while employed. No changes were associated with SO(2) exposure or and SO(2) dust interaction. These findings suggest that employment in SiC production is associated with an excessive decrement in pulmonary function and that current permissible exposure limits for dusts occurring in this industry may not adequately protect workers from developing chronic pulmonary disease. PMID:2818959

  13. Serum Bilirubin and Disease Progression in Mild COPD

    PubMed Central

    Apperley, Scott; Park, Hye Yun; Holmes, Daniel T.; Wise, Robert A.; Connett, John E.

    2015-01-01

    BACKGROUND: COPD is a chronic inflammatory disorder associated with oxidative stress. Serum bilirubin has potent antioxidant actions, and higher concentrations have been shown to protect against oxidative stress. The relation between serum bilirubin and COPD progression is unknown. METHODS: Serum bilirubin was measured in 4,680 smokers aged 35 to 60 years old with mild to moderate airflow limitation. The relationship of serum bilirubin to postbronchodilator FEV1 and rate of FEV1 decline over 3 to 9 years was determined using regression modeling. Total and disease-specific mortality were also ascertained. RESULTS: Serum bilirubin was positively related to FEV1 (P < .001). Serum bilirubin was also negatively related to the annual decline in FEV1 when adjusted for baseline demographics, pack-years smoked, and baseline measures of lung function (P = .01). Additionally, serum bilirubin was negatively associated with risk of death from coronary heart disease (P = .03); however, the relationships between bilirubin and other mortality end points were not statistically significant (P > .05). CONCLUSIONS: Bilirubin is inversely related to COPD disease severity and progression. Higher serum bilirubin concentration was associated with a higher FEV1 and less annual decline in FEV1. Bilirubin was also associated with less coronary heart disease mortality. These data support the hypothesis that bilirubin has a protective effect on COPD disease progression, possibly through its antioxidant actions. Bilirubin may prove useful as an easily accessible and readily available blood-based COPD biomarker. PMID:25539285

  14. Predicted equations for ventilatory function among Kuching (Sarawak, Malaysia) population.

    PubMed

    Djojodibroto, R D; Pratibha, G; Kamaluddin, B; Manjit, S S; Sumitabha, G; Kumar, A Deva; Hashami, B

    2009-12-01

    Spirometry data of 869 individuals (males and females) between the ages of 10 to 60 years were analyzed. The analysis yielded the following conclusions: 1. The pattern of Forced Vital Capacity (FVC) and Forced Expiratory Volume in One Second (FEV1) for the selected subgroups seems to be gender dependant: in males, the highest values were seen in the Chinese, followed by the Malay, and then the Dayak; in females, the highest values were seen in the Chinese, followed by the Dayak, and then the Malay. 2. Smoking that did not produce respiratory symptom was not associated with a decline in lung function, in fact we noted higher values in smokers as compared to nonsmokers. 3. Prediction formulae (54 in total) are worked out for FVC & FEV1 for the respective gender and each of the selected subgroups.

  15. Lung volumes identify an at-risk group in persons with prolonged secondhand tobacco smoke exposure but without overt airflow obstruction.

    PubMed

    Arjomandi, Mehrdad; Zeng, Siyang; Geerts, Jeroen; Stiner, Rachel K; Bos, Bruce; van Koeverden, Ian; Keene, Jason; Elicker, Brett; Blanc, Paul D; Gold, Warren M

    2018-01-01

    Exposure to secondhand smoke (SHS) is associated with occult obstructive lung disease as evident by abnormal airflow indices representing small airway disease despite having preserved spirometry (normal forced expiratory volume in 1 s-to-forced vital capacity ratio, FEV 1 /FVC). The significance of lung volumes that reflect air trapping in the presence of preserved spirometry is unclear. To investigate whether lung volumes representing air trapping could determine susceptibility to respiratory morbidity in people with SHS exposure but without spirometric chronic obstructive pulmonary disease, we examined a cohort of 256 subjects with prolonged occupational SHS exposure and preserved spirometry. We elicited symptom prevalence by structured questionnaires, examined functional capacity (maximum oxygen uptake, VO 2max ) by exercise testing, and estimated associations of those outcomes with air trapping (plethysmography-measured residual volume-to-total lung capacity ratio, RV/TLC), and progressive air trapping with exertion (increase in fraction of tidal breathing that is flow limited on expiration during exercise (per cent of expiratory flow limitation, %EFL)). RV/TLC was within the predicted normal limits, but was highly variable spanning 22%±13% and 16%±8% across the increments of FEV 1 /FVC and FEV 1 , respectively. Respiratory complaints were prevalent (50.4%) with the most common symptom being ≥2 episodes of cough per year (44.5%). Higher RV/TLC was associated with higher OR of reporting respiratory symptoms (n=256; r 2 =0.03; p=0.011) and lower VO 2max (n=179; r 2 =0.47; p=0.013), and %EFL was negatively associated with VO 2max (n=32; r 2 =0.40; p=0.017). In those at risk for obstruction due to SHS exposure but with preserved spirometry, higher RV/TLC identifies a subgroup with increased respiratory symptoms and lower exercise capacity.

  16. DISTRIBUTION OF FORCED VITAL CAPACITY AND FORCED EXPIRATORY VOLUME IN ONE SECOND IN CHILDREN 6 TO 11 YEARS OF AGE

    EPA Science Inventory

    The authors analyzed 44,664 annual measurements of forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) in 12,258 white children and 1,041 black children between 6 and 11 years of age in 6 communities. Sex and race-specific lung function development is de...

  17. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    NASA Astrophysics Data System (ADS)

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-06-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange.

  18. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    PubMed Central

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-01-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange. PMID:27311826

  19. Association of five genetic variants with chronic obstructive pulmonary disease susceptibility and spirometric phenotypes in a Chinese Han population.

    PubMed

    Yang, Jing; Zhou, Haixia; Liang, Binmiao; Xiao, Jun; Su, Zhiguang; Chen, Hong; Ma, Chunlan; Li, Dengxue; Feng, Yulin; Ou, Xuemei

    2014-02-01

    Recent genome-wide association studies have shown associations between variants at five loci (TNS1, GSTCD, HTR4, AGER and THSD4) and chronic obstructive pulmonary disease (COPD) or lung function. However, their association with COPD has not been proven in Chinese Han population, nor have COPD-related phenotypes been studied. The objective of this study was to look for associations between five single nucleotide polymorphisms (SNP) in these novel candidate genes and COPD susceptibility or lung function in a Chinese Han population. Allele and genotype data on 680 COPD patients and 687 healthy controls for sentinel SNP in these five loci were investigated. Allele frequencies and genotype distributions were compared between cases and controls, and odds ratios were calculated. Potential relationships between these SNP and COPD-related lung function were assessed. No significant associations were found between any of the SNP and COPD in cases and controls. The SNP (rs3995090) in HTR4 was associated with COPD (adjusted P = 0.022) in never-smokers, and the SNP (rs2070600) in AGER was associated with forced expiratory volume in 1 s (FEV1 %) predicted (β = -0.066, adjusted P = 0.016) and FEV1 /forced vital capacity (β = -0.071, adjusted P = 0.009) in all subjects. The variant at HTR4 was associated with COPD in never-smokers, and the SNP in AGER was associated with pulmonary function in a Chinese Han population. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  20. Bronchoarterial ratio in never-smokers adults: Implications for bronchial dilation definition.

    PubMed

    Diaz, Alejandro A; Young, Thomas P; Maselli, Diego J; Martinez, Carlos H; Maclean, Erick S; Yen, Andrew; Dass, Chandra; Simpson, Scott A; Lynch, David A; Kinney, Gregory L; Hokanson, John E; Washko, George R; San José Estépar, Raul

    2017-01-01

    Bronchiectasis manifests as recurrent respiratory infections and reduced lung function. Airway dilation, which is measured as the ratio of the diameters of the bronchial lumen (B) and adjacent pulmonary artery (A), is a defining radiological feature of bronchiectasis. A challenge to equating the bronchoarterial (BA) ratio to disease severity is that the diameters of airway and vessel in health are not established. We sought to explore the variability of BA ratio in never-smokers without pulmonary disease and its associations with lung function. Objective measurements of the BA ratio on volumetric computed tomography (CT) scans and pulmonary function data were collected in 106 never-smokers. The BA ratio was measured in the right upper lobe apical bronchus (RB1) and the right lower lobe basal posterior bronchus. The association between the BA ratio and forced expiratory volume in 1 s (FEV 1 ) was assessed using regression analysis. The BA ratio was 0.79 ± 0.16 and was smaller in more peripheral RB1 bronchi (P < 0.0001). The BA ratio was >1, a typical threshold for bronchiectasis, in 10 (8.5%) subjects. Subjects with a BA ratio >1 versus ≤1 had smaller artery diameters (P < 0.0001) but not significantly larger bronchial lumens. After adjusting for age, gender, race and height, the BA ratio was directly related to FEV 1 (P = 0.0007). In never-smokers, the BA ratio varies by airway generation and is associated with lung function. A BA ratio >1 is driven by small arteries. Using artery diameter as reference to define bronchial dilation seems inappropriate. © 2016 Asian Pacific Society of Respirology.

  1. [Lung volume reduction surgery in advanced emphysema--results of the Washington University, St. Louis].

    PubMed

    Cooper, J D; Gaissert, H A; Patterson, G A; Pohl, M S; Yusen, R D; Trulock, E P

    1996-01-01

    The aim of lung volume reduction surgery is to alleviate the symptoms of severe emphysema and to improve the life quality of the patient. The appropriate candidates (approximately 20% of all emphysematic patients examined in our clinic) had considerable dyspnea, an increased lung capacity, and a heterogenous dissemination of the emphysema with regional destruction of the parenchyma, hyperinflation and poor perfusion. After preoperative physiotherapie with a specified rehabilitation aim, a resection of 20 to 30% of the total lung volume was performed via sternotomy. From January 1993 to February 1996, 150 patients underwent bilateral lung volume reduction (age range = 36 to 77 years). The mean forced expiratory volume in 1 s (FEV1) was preoperatively 25% of the predicted value, the total lung capacity (TLC) 142% and the residual volume (RV) 283%, 94% of these patients necessitated oxygen supply at rest or during exercise. The 90-day mortality was 4%. All patients except 1 were extubated immediately after operation. The median hospital stay was 10 days in the first 100 patients and 7 days in the last 50. An increase of the FEV1 by 51% and a decrease of the RV by 28% was observed 6 months after operation. The mean PaO2 was improved by 8 mm Hg while the percentage of oxygen dependent patients went down from 50 to 16%. In addition a raise of the perseverance capacity, a clear decrease of dyspnea and an improvement of the life quality were achieved. These results persist after 1 (n = 56) and 2 (n = 20) years after operation. Lung volume reduction leads to an improvement of the lung function, symptoms and the quality of life, which is superior to that achieved by maximal clinical intervention.

  2. [Lung transplantation in pulmonary fibrosis and other interstitial lung diseases].

    PubMed

    Berastegui, Cristina; Monforte, Victor; Bravo, Carlos; Sole, Joan; Gavalda, Joan; Tenório, Luis; Villar, Ana; Rochera, M Isabel; Canela, Mercè; Morell, Ferran; Roman, Antonio

    2014-09-15

    Interstitial lung disease (ILD) is the second indication for lung transplantation (LT) after emphysema. The aim of this study is to review the results of LT for ILD in Hospital Vall d'Hebron (Barcelona, Spain). We retrospectively studied 150 patients, 87 (58%) men, mean age 48 (r: 20-67) years between August 1990 and January 2010. One hundred and four (69%) were single lung transplants (SLT) and 46 (31%) bilateral-lung transplants (BLT). The postoperative diagnoses were: 94 (63%) usual interstitial pneumonia, 23 (15%) nonspecific interstitial pneumonia, 11 (7%) unclassifiable interstitial pneumonia and 15% miscellaneous. We describe the functional results, complications and survival. The actuarial survival was 87, 70 and 53% at one, 3 and 5 years respectively. The most frequent causes of death included early graft dysfunction and development of chronic rejection in the form of bronchiolitis obliterans (BOS). The mean postoperative increase in forced vital capacity and forced expiratory volume in the first second (FEV1) was similar in SLT and BLT. The best FEV1 was reached after 10 (r: 1-36) months. Sixteen percent of patients returned to work. At some point during the evolution, proven acute rejection was diagnosed histologically in 53 (35%) patients. The prevalence of BOS among survivors was 20% per year, 45% at 3 years and 63% at 5 years. LT is the best treatment option currently available for ILD, in which medical treatment has failed. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  3. Physiological and computed tomographic predictors of outcome from lung volume reduction surgery.

    PubMed

    Washko, George R; Martinez, Fernando J; Hoffman, Eric A; Loring, Stephen H; Estépar, Raúl San José; Diaz, Alejandro A; Sciurba, Frank C; Silverman, Edwin K; Han, MeiLan K; Decamp, Malcolm; Reilly, John J

    2010-03-01

    Previous investigations have identified several potential predictors of outcomes from lung volume reduction surgery (LVRS). A concern regarding these studies has been their small sample size, which may limit generalizability. We therefore sought to examine radiographic and physiologic predictors of surgical outcomes in a large, multicenter clinical investigation, the National Emphysema Treatment Trial. To identify objective radiographic and physiological indices of lung disease that have prognostic value in subjects with chronic obstructive pulmonary disease being evaluated for LVRS. A subset of the subjects undergoing LVRS in the National Emphysema Treatment Trial underwent preoperative high-resolution computed tomographic (CT) scanning of the chest and measures of static lung recoil at total lung capacity (SRtlc) and inspiratory resistance (Ri). The relationship between CT measures of emphysema, the ratio of upper to lower zone emphysema, CT measures of airway disease, SRtlc, Ri, the ratio of residual volume to total lung capacity (RV/TLC), and both 6-month postoperative changes in FEV(1) and maximal exercise capacity were assessed. Physiological measures of lung elastic recoil and inspiratory resistance were not correlated with improvement in either the FEV(1) (R = -0.03, P = 0.78 and R = -0.17, P = 0.16, respectively) or maximal exercise capacity (R = -0.02, P = 0.83 and R = 0.08, P = 0.53, respectively). The RV/TLC ratio and CT measures of emphysema and its upper to lower zone ratio were only weakly predictive of postoperative changes in both the FEV(1) (R = 0.11, P = 0.01; R = 0.2, P < 0.0001; and R = 0.23, P < 0.0001, respectively) and maximal exercise capacity (R = 0.17, P = 0.0001; R = 0.15, P = 0.002; and R = 0.15, P = 0.002, respectively). CT assessments of airway disease were not predictive of change in FEV(1) or exercise capacity in this cohort. The RV/TLC ratio and CT measures of emphysema and its distribution are weak but statistically significant predictors of outcome after LVRS.

  4. Lung function in adults following in utero and childhood exposure to arsenic in drinking water: preliminary findings.

    PubMed

    Dauphiné, David C; Ferreccio, Catterina; Guntur, Sandeep; Yuan, Yan; Hammond, S Katharine; Balmes, John; Smith, Allan H; Steinmaus, Craig

    2011-08-01

    Evidence suggests that arsenic in drinking water causes non-malignant lung disease, but nearly all data concern exposed adults. The desert city of Antofagasta (population 257,976) in northern Chile had high concentrations of arsenic in drinking water (>800 μg/l) from 1958 until 1970, when a new treatment plant was installed. This scenario, with its large population, distinct period of high exposure, and accurate data on past exposure, is virtually unprecedented in environmental epidemiology. We conducted a pilot study on early-life arsenic exposure and long-term lung function. We present these preliminary findings because of the magnitude of the effects observed. We recruited a convenience sample consisting primarily of nursing school employees in Antofagasta and Arica, a city with low drinking water arsenic. Lung function and respiratory symptoms in 32 adults exposed to >800 μg/l arsenic before age 10 were compared to 65 adults without high early-life exposure. Early-life arsenic exposure was associated with 11.5% lower forced expiratory volume in 1 s (FEV(1)) (P = 0.04), 12.2% lower forced vital capacity (FVC) (P = 0.04), and increased breathlessness (prevalence odds ratio = 5.94, 95% confidence interval 1.36-26.0). Exposure-response relationships between early-life arsenic concentration and adult FEV(1) and FVC were also identified (P trend = 0.03). Early-life exposure to arsenic in drinking water may have irreversible respiratory effects of a magnitude similar to smoking throughout adulthood. Given the small study size and non-random recruitment methods, further research is needed to confirm these findings.

  5. Effects of simvastatin in chronic obstructive pulmonary disease: Results of a pilot, randomized, placebo-controlled clinical trial.

    PubMed

    Balaguer, Catalina; Peralta, Alejandro; Ríos, Ángel; Iglesias, Amanda; Valera, Josep Lluís; Noguera, Aina; Soriano, Joan B; Agustí, Àlvar; Sala-Llinas, Ernest

    2016-04-15

    Statins may have pleiotropic effects in COPD, but mechanisms remain unclear. To assess the pleiotropic effect of statins in patients with stable COPD on ( 1 ): lung function ( 2 ); pulmonary and systemic inflammation ( 3 ); endothelial function (vascular stiffness) and circulating vascular growth factors; and ( 4 ), serum uric acid levels. Pilot, double-blind, randomized, placebo-controlled clinical trial in 24 patients with stable COPD, all statin-naïve, who were randomized (1:1) to receive simvastatin 40 mg/24 h during 12 weeks (n = 12; 69.0 ± 7.3 years; post-bd FEV 1 53.4 ± 10.0% pred.) or placebo (n = 12; 66.4 ± 4.6 years; post-bd FEV 1 48.2 ± 12.6% pred.). Nine patients per group (total n = 18) completed the study. Lung function, pulmonary and systemic inflammatory markers and the degree of vascular stiffness did not change significantly in any group. However, treatment with simvastatin increased the plasma levels of erythropoietin (Epo) (4.2 ± 2.2 mIU/mL to 6.8 ± 3.2 mlU/mL, p < 0.05) and reduced those of serum uric acid (7.1 ± 1.3 mg/dL to 6.5 ± 1.4 mg/dL, p < 0.01). Short-term treatment with simvastatin in stable COPD patients did not modify lung function, pulmonary and systemic inflammation, or vascular stiffness, but it changed Epo and uric acid levels.

  6. [Study of the clinical phenotype of symptomatic chronic airways disease by hierarchical cluster analysis and two-step cluster analyses].

    PubMed

    Ning, P; Guo, Y F; Sun, T Y; Zhang, H S; Chai, D; Li, X M

    2016-09-01

    To study the distinct clinical phenotype of chronic airway diseases by hierarchical cluster analysis and two-step cluster analysis. A population sample of adult patients in Donghuamen community, Dongcheng district and Qinghe community, Haidian district, Beijing from April 2012 to January 2015, who had wheeze within the last 12 months, underwent detailed investigation, including a clinical questionnaire, pulmonary function tests, total serum IgE levels, blood eosinophil level and a peak flow diary. Nine variables were chosen as evaluating parameters, including pre-salbutamol forced expired volume in one second(FEV1)/forced vital capacity(FVC) ratio, pre-salbutamol FEV1, percentage of post-salbutamol change in FEV1, residual capacity, diffusing capacity of the lung for carbon monoxide/alveolar volume adjusted for haemoglobin level, peak expiratory flow(PEF) variability, serum IgE level, cumulative tobacco cigarette consumption (pack-years) and respiratory symptoms (cough and expectoration). Subjects' different clinical phenotype by hierarchical cluster analysis and two-step cluster analysis was identified. (1) Four clusters were identified by hierarchical cluster analysis. Cluster 1 was chronic bronchitis in smokers with normal pulmonary function. Cluster 2 was chronic bronchitis or mild chronic obstructive pulmonary disease (COPD) patients with mild airflow limitation. Cluster 3 included COPD patients with heavy smoking, poor quality of life and severe airflow limitation. Cluster 4 recognized atopic patients with mild airflow limitation, elevated serum IgE and clinical features of asthma. Significant differences were revealed regarding pre-salbutamol FEV1/FVC%, pre-salbutamol FEV1% pred, post-salbutamol change in FEV1%, maximal mid-expiratory flow curve(MMEF)% pred, carbon monoxide diffusing capacity per liter of alveolar(DLCO)/(VA)% pred, residual volume(RV)% pred, total serum IgE level, smoking history (pack-years), St.George's respiratory questionnaire(SGRQ) score, acute exacerbation in the past one year, PEF variability and allergic dermatitis (P<0.05). (2) Four clusters were also identified by two-step cluster analysis as followings, cluster 1, COPD patients with moderate to severe airflow limitation; cluster 2, asthma and COPD patients with heavy smoking, airflow limitation and increased airways reversibility; cluster 3, patients having less smoking and normal pulmonary function with wheezing but no chronic cough; cluster 4, chronic bronchitis patients with normal pulmonary function and chronic cough. Significant differences were revealed regarding gender distribution, respiratory symptoms, pre-salbutamol FEV1/FVC%, pre-salbutamol FEV1% pred, post-salbutamol change in FEV1%, MMEF% pred, DLCO/VA% pred, RV% pred, PEF variability, total serum IgE level, cumulative tobacco cigarette consumption (pack-years), and SGRQ score (P<0.05). By different cluster analyses, distinct clinical phenotypes of chronic airway diseases are identified. Thus, individualized treatments may guide doctors to provide based on different phenotypes.

  7. Decrements in lung function related to arsenic in drinking water in West Bengal, India.

    PubMed

    von Ehrenstein, Ondine S; Mazumder, D N Guha; Yuan, Yan; Samanta, Sambit; Balmes, John; Sil, Arabinda; Ghosh, Nilima; Hira-Smith, Meera; Haque, Reina; Purushothamam, Radhika; Lahiri, Sarbari; Das, Subhankar; Smith, Allan H

    2005-09-15

    During 1998-2000, the authors investigated relations between lung function, respiratory symptoms, and arsenic in drinking water among 287 study participants, including 132 with arsenic-caused skin lesions, in West Bengal, India. The source population involved 7,683 participants who had been surveyed for arsenic-related skin lesions in 1995-1996. Respiratory symptoms were increased among men with arsenic-caused skin lesions (versus those without lesions), particularly "shortness of breath at night" (odds ratio (OR) = 2.8, 95% confidence interval (CI): 1.1, 7.6) and "morning cough" (OR = 2.8, 95% CI: 1.2, 6.6) in smokers and "shortness of breath ever" (OR = 3.8, 95% CI: 0.7, 20.6) in nonsmokers. Among men with skin lesions, the average adjusted forced expiratory volume in 1 second (FEV1) was reduced by 256.2 ml (95% CI: 113.9, 398.4; p < 0.001) and the average adjusted forced vital capacity (FVC) was reduced by 287.8 ml (95% CI: 134.9, 440.8; p < 0.001). In men, a 100-microg/liter increase in arsenic level was associated with a 45.0-ml decrease (95% CI: 6.2, 83.9) in FEV1 (p = 0.02) and a 41.4-ml decrease (95% CI: -0.7, 83.5) in FVC (p = 0.054). Women had lower risks than men of developing skin lesions and showed little evidence of respiratory effects. In this study, consumption of arsenic-contaminated water was associated with respiratory symptoms and reduced lung function in men, especially among those with arsenic-related skin lesions.

  8. Spirometry and volumetric capnography in lung function assessment of obese and normal-weight individuals without asthma.

    PubMed

    Ferreira, Mariana S; Mendes, Roberto T; Marson, Fernando A L; Zambon, Mariana P; Antonio, Maria A R G M; Paschoal, Ilma A; Toro, Adyléia A D C; Severino, Silvana D; Ribeiro, Maria A G O; Ribeiro, José D

    To analyze and compare lung function of obese and healthy, normal-weight children and adolescents, without asthma, through spirometry and volumetric capnography. Cross-sectional study including 77 subjects (38 obese) aged 5-17 years. All subjects underwent spirometry and volumetric capnography. The evaluations were repeated in obese subjects after the use of a bronchodilator. At the spirometry assessment, obese individuals, when compared with the control group, showed lower values of forced expiratory volume in the first second by forced vital capacity (FEV 1 /FVC) and expiratory flows at 75% and between 25 and 75% of the FVC (p<0.05). Volumetric capnography showed that obese individuals had a higher volume of produced carbon dioxide and alveolar tidal volume (p<0.05). Additionally, the associations between dead space volume and tidal volume, as well as phase-3 slope normalized by tidal volume, were lower in healthy subjects (p<0.05). These data suggest that obesity does not alter ventilation homogeneity, but flow homogeneity. After subdividing the groups by age, a greater difference in lung function was observed in obese and healthy individuals aged >11 years (p<0.05). Even without the diagnosis of asthma by clinical criteria and without response to bronchodilator use, obese individuals showed lower FEV 1 /FVC values and forced expiratory flow, indicating the presence of an obstructive process. Volumetric capnography showed that obese individuals had higher alveolar tidal volume, with no alterations in ventilation homogeneity, suggesting flow alterations, without affecting lung volumes. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  9. Reduced vital capacity after methacholine challenge in early childhood--is it due to trapped air or loss of motivation.

    PubMed

    Vilozni, Daphna; Hakim, Fahed; Adler, Adi; Livnat, Galit; Bar-Yishay, Ephraim; Bentur, Lea

    2009-01-01

    In a previous study we assessed the feasibility of measuring bronchial-reactivity (BHR) in young asthmatic children by the determination of PC(20)-FEV(1) along with clinical end-of-test criteria during a methacholine challenge test (MCT). The end-point was associated with a significant reduction in both flow and vital capacity values. The findings could be due to the children's loss of motivation, which may preclude use of this test. Alternatively, if it reflects air trapping during airway obstruction, it might reinforce its applicability in preschool age children. To elucidate the mechanism of low vital capacity at PC(20)-FEV(1) in preschool age children. Twenty-eight children (3.3-6.9 years) with recurrent respiratory symptoms. An MCT was carried out using tripling doses (0.06-13.9 mg/ml) delivered by a dosimeter. Spirometry was measured at baseline and after each inhalation in duplicate sets. Whole body plethysmography was measured at baseline and at end-of-test (defined by clinical criteria) according to the recommendations for older populations. Plethysmography was reliably performed by 20 children before and after MCT. At baseline, lung function was within the healthy range. At end-of-test (PC(20)-FEV(1)=4.02+/-3.47 mg/ml), the spirometry parameters and specific conductance values were markedly reduced in correlation with a significant increase in residual volume and resistance. The study shows that diminished vital capacity is due to the increase in FRC at end-of-test. Our findings support the use of PC(20)-FEV(1) during BHR in young children and suggest that lung volume measurement by a plethysmograph may be feasible in early childhood. Larger studies should be performed to establish the clinical applicability of PC20-FEV1 determination in the preschool age.

  10. Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows.

    PubMed Central

    Schreur, H J; Sterk, P J; Vanderschoot, J; van Klink, H C; van Vollenhoven, E; Dijkman, J H

    1992-01-01

    BACKGROUND: A common auscultatory finding in pulmonary emphysema is a reduction of lung sounds. This might be due to a reduction in the generation of sounds due to the accompanying airflow limitation or to poor transmission of sounds due to destruction of parenchyma. Lung sound intensity was investigated in normal and emphysematous subjects in relation to airflow. METHODS: Eight normal men (45-63 years, FEV1 79-126% predicted) and nine men with severe emphysema (50-70 years, FEV1 14-63% predicted) participated in the study. Emphysema was diagnosed according to pulmonary history, results of lung function tests, and radiographic criteria. All subjects underwent phonopneumography during standardised breathing manoeuvres between 0.5 and 2 1 below total lung capacity with inspiratory and expiratory target airflows of 2 and 1 l/s respectively during 50 seconds. The synchronous measurements included airflow at the mouth and lung volume changes, and lung sounds at four locations on the right chest wall. For each microphone airflow dependent power spectra were computed by using fast Fourier transformation. Lung sound intensity was expressed as log power (in dB) at 200 Hz at inspiratory flow rates of 1 and 2 l/s and at an expiratory flow rate of 1 l/s. RESULTS: Lung sound intensity was well repeatable on two separate days, the intraclass correlation coefficient ranging from 0.77 to 0.94 between the four microphones. The intensity was strongly influenced by microphone location and airflow. There was, however, no significant difference in lung sound intensity at any flow rate between the normal and the emphysema group. CONCLUSION: Airflow standardised lung sound intensity does not differ between normal and emphysematous subjects. This suggests that the auscultatory finding of diminished breath sounds during the regular physical examination in patients with emphysema is due predominantly to airflow limitation. Images PMID:1440459

  11. Systemic inflammation in 222.841 healthy employed smokers and nonsmokers: white blood cell count and relationship to spirometry

    PubMed Central

    2012-01-01

    Background Smoking has been linked to low-grade systemic inflammation, a known risk factor for disease. This state is reflected in elevated white blood cell (WBC) count. Objective We analyzed the relationship between WBC count and smoking in healthy men and women across several age ranges who underwent preventive medical check-ups in the workplace. We also analysed the relationship between smoking and lung function. Methods Cross-sectional descriptive study in 163 459 men and 59 382 women aged between 16 and 70 years. Data analysed were smoking status, WBC count, and spirometry readings. Results Total WBC showed higher counts in both male and female smokers, around 1000 to 1300 cell/ml (t test, P < 0.001). Forced expiratory volume in 1 second (FEV1%) was higher in nonsmokers for both sexes between 25 to 54 years (t test, P < 0.001). Analysis of covariance showed a multiple variable effect of age, sex, smoking status, body mass index on WBC count. The relationship between WBC blood count and smoking status was confirmed after the sample was stratified for these variables. Smokers with airway obstruction measured by FEV1% were found to have higher WBC counts, in comparison to smokers with a normal FEV1% among similar age and BMI groups. Conclusions Smoking increases WBC count and affects lung function. The effects are evident across a wide age range, underlining the importance of initiating preventive measures as soon as an individual begins to smoke. PMID:22613769

  12. Effectiveness of ivacaftor in cystic fibrosis patients with non-G551D gating mutations.

    PubMed

    Guimbellot, Jennifer; Solomon, George M; Baines, Arthur; Heltshe, Sonya L; VanDalfsen, Jill; Joseloff, Elizabeth; Sagel, Scott D; Rowe, Steven M

    2018-04-20

    The cystic fibrosis transmembrane conductance regulator (CFTR) potentiator ivacaftor is approved for patients with CF with gating and residual function CFTR mutations. We report the results of an observational study investigating its effects in CF patients with non-G551D gating mutations. Patients with non-G551D gating mutations were recruited to an open-label study evaluating ivacaftor. Primary outcomes included: lung function, sweat chloride, weight gain, and quality of life scores. Twenty-one subjects were enrolled and completed 6 months follow-up on ivacaftor; mean age was 25.6 years with 52% <18. Baseline ppFEV 1 was 68% and mean sweat chloride 89.6 mEq/L. Participants experienced significant improvements in ppFEV 1 (mean absolute increase of 10.9% 95% CI = [2.6,19.3], p = 0.0134), sweat chloride (-48.6 95% CI = [-67.4,-29.9], p < 0.0001), and weight (5.1 kg, 95% CI = [2.8, 7.3], p = 0.0002). Patients with non-G551D gating mutations experienced improved lung function, nutritional status, and quality of life. This study supports ongoing use of ivacaftor for patients with these mutations. Copyright © 2018. Published by Elsevier B.V.

  13. Changes of clinical outcomes and health care resources in moderate and in severe COPD treated uniquely with tiotropium 18 mcg od for twenty-four months.

    PubMed

    Dal Negro, R W; Bonadiman, L; Micheletto, C; Tognella, S; Turati, C; Turco, P

    2011-08-01

    Chronic obstructive pulmonary disease (COPD) is a complex and progressive respiratory disease characterized by incompletely reversible bronchial obstruction. The effects of current therapeutic options in early stages of COPD have been poorly investigated in the past, being this specific topic revamped by the results of recent secondary analyses from large international trials. To measure and monitor in real life the changes in main clinical outcomes and health care resources in patients suffering from mild-to-moderate and severe COPD treated with only tiotropium br. for twenty-four months. The population sample of the present observational retrospective study consists of 319 COPD subjects (214 males; average age 71.7 years ± 06 se) automatically extracted from the DataBase of the Health Care Institution. Inclusion criteria were: age ≥ 40 y; basal FEV1 < 80% predicted and FEV1/FVC < 70%; regular treatment with only 18 mcg tiotropium br. for the following two years. All subjects were divided into two subsets according to their FEV1 basal value: (Group A ≤ 50%, and Group B >50% predicted). Lung function; n. exacerbations; n. hospitalizations; absenteeism; n. GP's visits, and use of systemic steroids or antibiotics were checked during the observational period and mean values compared in both subsets with those of the twelve months preceding tiotropium br. (such as during other therapeutic strategies). T test was used for checking the comparability of groups, while ANOVA--Duncan test was used to compare the trends of all variables over time; p < 0.05 was accepted. Group A, 154 individuals (104 males; mean age 72.1 years ± 0.51 se) had a mean FEV1 value of 45.4% pred. ± 0.61 se, while the remaining 165, Group B (111 males; mean age 71.4 years ± 0.60 se) had a mean FEV1 value of 65.5% pred. ± 5.7 se (p < 0,01). The two subsets were well matched for gender, age, and previous use of systemic steroids, but significantly different in terms of basal lung function, COPD morbidity, and antibiotic use. Basically, the impact of COPD confirmed higher in severe patients even if it was unexpectedly remarkable in mild-to-moderate individuals in terms of consumption of health care resources. The overall reduction in COPD morbidity was significant in both groups, but the improvement in FEV1 and in other main long-term outcomes observed in subjects with mild-to-moderate COPD was particularly significant and substantial (p < 0.001), these subjects confirming to be worth of earlier therapeutic attention. 18 mcg tiotropium br. monotherapy for twenty-four months on a regular daily basis enables a significant minimization of COPD impact, and consents the progressive lung function recovery also in mild-to-moderate individuals, thus suggesting a possible role of tiotropium br. in affecting the natural history of COPD. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Correlation of sweat chloride and percent predicted FEV1 in cystic fibrosis patients treated with ivacaftor.

    PubMed

    Fidler, Meredith C; Beusmans, Jack; Panorchan, Paul; Van Goor, Fredrick

    2017-01-01

    Ivacaftor, a CFTR potentiator that enhances chloride transport by acting directly on CFTR to increase its channel gating activity, has been evaluated in patients with different CFTR mutations. Several previous analyses have reported no statistical correlation between change from baseline in ppFEV 1 and reduction in sweat chloride levels for individuals treated with ivacaftor. The objective of the post hoc analysis described here was to expand upon previous analyses and evaluate the correlation between sweat chloride levels and absolute ppFEV 1 changes across multiple cohorts of patients with different CF-causing mutations who were treated with ivacaftor. The goal of the analysis was to help define the potential value of sweat chloride as a pharmacodynamic biomarker for use in CFTR modulator trials. For any given study, reductions in sweat chloride levels and improvements in absolute ppFEV 1 were not correlated for individual patients. However, when the data from all studies were combined, a statistically significant correlation between sweat chloride levels and ppFEV 1 changes was observed (p<0.0001). Thus, sweat chloride level changes in response to potentiation of the CFTR protein by ivacaftor appear to be a predictive pharmacodynamic biomarker of lung function changes on a population basis but are unsuitable for the prediction of treatment benefits for individuals. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Predictors of clinical outcome in emphysema patients with atelectasis following endoscopic valve therapy: A retrospective study.

    PubMed

    Gompelmann, Daniela; Hofbauer, Tobias; Gerovasili, Vasiliki; Eberhardt, Ralf; Lim, Hyun-Ju; Herth, Felix; Heussel, Claus-Peter

    2016-10-01

    The aim of endoscopic valve therapy in patients with emphysema is complete lobar atelectasis of the most emphysematous lobe. However, even after the radiological advent of atelectasis, great variability in clinical outcomes can be observed. The baseline clinical measures (vital capacity (VC), forced expiratory flow in 1 s (FEV1 ), residual volume (RV) and 6-min walk test (6-MWT)) and computed tomography variables (low attenuation volume (LAV) of the target lobe, LAV% of the target and the ipsilateral untreated lobe and LAV of the target lobe to LAV of the target lung and to LAV of the total lung) of 77 patients with complete atelectasis following valve therapy were retrospectively examined to determine their impact on patient´s outcome (changes in VC, FEV1 , RV and 6-MWT from baseline to the time of atelectasis). Low attenuation volume of the target lobe to LAV of the target lung predicts a significant FEV1 improvement in patients with complete lobar atelectasis following valve therapy. A 10% difference in that computed tomography predictor was associated with a 82-mL improvement in FEV1 (P = 0.006). Lower 6-MWT scores, low VC and high RV at baseline were significantly associated with greater improvement in the respective parameter (all P < 0.001). Low attenuation volume of the target lobe to LAV of the target lung and baseline clinical measures seem to significantly predict clinical outcomes in patients with complete lobar atelectasis following valve treatment. © 2016 Asian Pacific Society of Respirology.

  16. Early detection of cystic fibrosis lung disease: multiple‐breath washout versus raised volume tests

    PubMed Central

    Lum, Sooky; Gustafsson, Per; Ljungberg, Henrik; Hülskamp, Georg; Bush, Andrew; Carr, Siobhán B; Castle, Rosemary; Hoo, Ah‐fong; Price, John; Ranganathan, Sarath; Stroobant, John; Wade, Angie; Wallis, Colin; Wyatt, Hilary; Stocks, Janet

    2007-01-01

    Background Lung clearance index (LCI), a measure of ventilation inhomogeneity derived from the multiple‐breath inert gas washout (MBW) technique, has been shown to detect abnormal lung function more readily than spirometry in preschool children with cystic fibrosis, but whether this holds true during infancy is unknown. Objectives To compare the extent to which parameters derived from the MBW and the raised lung volume rapid thoraco–abdominal compression (RVRTC) techniques identify diminished airway function in infants with cystic fibrosis when compared with healthy controls. Methods Measurements were performed during quiet sleep, with the tidal breathing MBW technique being performed before the forced expiratory manoeuvres. Results Measurements were obtained in 39 infants with cystic fibrosis (mean (SD) age 41.4 (22.0) weeks) and 21 controls (37.0 (15.1) weeks). Infants with cystic fibrosis had a significantly higher respiratory rate (38 (10) vs 32 (5) bpm) and LCI (8.4 (1.5) vs 7.2 (0.3)), and significantly lower values for all forced expiratory flow‐volume parameters compared with controls. Girls with cystic fibrosis had significantly lower forced expiratory volume (FEV0.5 and FEF25–75 ) than boys (mean (95% CI girls–boys): –1.2 (–2.1 to −0.3) for FEV0.5 Z score; FEF25–75: –1.2 (–2.2 to −0.15)). When using both the MBW and RVRTC techniques, abnormalities were detected in 72% of the infants with cystic fibrosis, with abnormalities detected in 41% using both techniques and a further 15% by each of the two tests performed. Conclusions These findings support the view that inflammatory and/or structural changes in the airways of children with cystic fibrosis start early in life, and have important implications regarding early detection and interventions. Monitoring of early lung disease and functional status in infants and young children with cystic fibrosis may be enhanced by using both MBW and the RVRTC. PMID:17121870

  17. Variable versus conventional lung protective mechanical ventilation during open abdominal surgery (PROVAR): a randomised controlled trial.

    PubMed

    Spieth, P M; Güldner, A; Uhlig, C; Bluth, T; Kiss, T; Conrad, C; Bischlager, K; Braune, A; Huhle, R; Insorsi, A; Tarantino, F; Ball, L; Schultz, M J; Abolmaali, N; Koch, T; Pelosi, P; Gama de Abreu, M

    2018-03-01

    Experimental studies showed that controlled variable ventilation (CVV) yielded better pulmonary function compared to non-variable ventilation (CNV) in injured lungs. We hypothesized that CVV improves intraoperative and postoperative respiratory function in patients undergoing open abdominal surgery. Fifty patients planned for open abdominal surgery lasting >3 h were randomly assigned to receive either CVV or CNV. Mean tidal volumes and PEEP were set at 8 ml kg -1 (predicted body weight) and 5 cm H 2 O, respectively. In CVV, tidal volumes varied randomly, following a normal distribution, on a breath-by-breath basis. The primary endpoint was the forced vital capacity (FVC) on postoperative Day 1. Secondary endpoints were oxygenation, non-aerated lung volume, distribution of ventilation, and pulmonary and extrapulmonary complications until postoperative Day 5. FVC did not differ significantly between CVV and CNV on postoperative Day 1, 61.5 (standard deviation 22.1) % vs 61.9 (23.6) %, respectively; mean [95% confidence interval (CI)] difference, -0.4 (-13.2-14.0), P=0.95. Intraoperatively, CVV did not result in improved respiratory function, haemodynamics, or redistribution of ventilation compared to CNV. Postoperatively, FVC, forced expiratory volume at the first second (FEV 1 ), and FEV 1 /FVC deteriorated, while atelectasis volume and plasma levels of interleukin-6 and interleukin-8 increased, but values did not differ between groups. The incidence of postoperative pulmonary and extrapulmonary complications was comparable in CVV and CNV. In patients undergoing open abdominal surgery, CVV did not improve intraoperative and postoperative respiratory function compared with CNV. NCT 01683578. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  18. Efficacy and Safety of Inhaled Aztreonam Lysine for Airway Pseudomonas in Cystic Fibrosis

    PubMed Central

    Retsch-Bogart, George Z.; Quittner, Alexandra L.; Gibson, Ronald L.; Oermann, Christopher M.; McCoy, Karen S.; Montgomery, A. Bruce; Cooper, Peter J.

    2009-01-01

    Background: We assessed the short-term efficacy and safety of aztreonam lysine for inhalation (AZLI [an aerosolized monobactam antibiotic]) in patients with cystic fibrosis (CF) and Pseudomonas aeruginosa (PA) airway infection. Methods: In this randomized, double-blind, placebo-controlled, international study (AIR-CF1 trial; June 2005 to April 2007), patients (n = 164; ≥ 6 years of age) with FEV1 ≥ 25% and ≤ 75% predicted values, and no recent use of antipseudomonal antibiotics or azithromycin were treated with 75 mg of AZLI (three times daily for 28 days) or placebo (1:1 randomization), then were monitored for 14 days after study drug completion. The primary efficacy end point was change in patient-reported respiratory symptoms (CF-Questionnaire-Revised [CFQ-R] Respiratory Scale). Secondary end points included changes in pulmonary function (FEV1), sputum PA density, and nonrespiratory CFQ-R scales. Adverse events and minimum inhibitory concentrations of aztreonam for PA were monitored. Results: After 28 days of treatment, AZLI improved the mean CFQ-R respiratory score (9.7 points; p < 0.001), FEV1 (10.3% predicted; p < 0.001), and sputum PA density (− 1.453 log10 cfu/g; p < 0.001), compared with placebo. Significant improvements in Eating, Emotional Functioning, Health Perceptions, Physical Functioning, Role Limitation/School Performance, and Vitality CFQ-R scales were observed. Adverse events were consistent with symptoms of CF lung disease and were comparable for AZLI and placebo except the incidence of “productive cough” was reduced by half in AZLI-treated patients. PA aztreonam susceptibility at baseline and end of therapy were similar. Conclusions: In patients with CF, PA airway infection, moderate-to-severe lung disease, and no recent use of antipseudomonal antibiotics or azithromycin, 28-day treatment with AZLI significantly improved respiratory symptoms and pulmonary function, and was well tolerated. Trial registration: Clinicaltrials.gov Identifier: NCT00112359 PMID:19420195

  19. Rationale and design of a randomized trial of home electronic symptom and lung function monitoring to detect cystic fibrosis pulmonary exacerbations: the early intervention in cystic fibrosis exacerbation (eICE) trial.

    PubMed

    Lechtzin, N; West, N; Allgood, S; Wilhelm, E; Khan, U; Mayer-Hamblett, N; Aitken, M L; Ramsey, B W; Boyle, M P; Mogayzel, P J; Goss, C H

    2013-11-01

    Acute pulmonary exacerbations are central events in the lives of individuals with cystic fibrosis (CF). Pulmonary exacerbations lead to impaired lung function, worse quality of life, and shorter survival. We hypothesized that aggressive early treatment of acute pulmonary exacerbation may improve clinical outcomes. Describe the rationale of an ongoing trial designed to determine the efficacy of home monitoring of both lung function measurements and symptoms for early detection and subsequent early treatment of acute CF pulmonary exacerbations. A randomized, non-blinded, multi-center trial in 320 individuals with CF aged 14 years and older. The study compares usual care to a twice a week assessment of home spirometry and CF respiratory symptoms using an electronic device with data transmission to the research personnel to identify and trigger early treatment of CF pulmonary exacerbation. Participants will be enrolled in the study for 12 months. The primary endpoint is change in FEV1 (L) from baseline to 12 months determined by a linear mixed effects model incorporating all quarterly FEV1 measurements. Secondary endpoints include time to first acute protocol-defined pulmonary exacerbation, number of acute pulmonary exacerbations, number of hospitalization days for acute pulmonary exacerbation, time from the end of acute pulmonary exacerbation to onset of subsequent pulmonary exacerbation, change in health related quality of life, change in treatment burden, change in CF respiratory symptoms, and adherence to the study protocol. This study is a first step in establishing alternative approaches to the care of CF pulmonary exacerbations. We hypothesize that early treatment of pulmonary exacerbations has the potential to slow lung function decline, reduce respiratory symptoms and improve the quality of life for individuals with CF. © 2013.

  20. Physiological correlates of pulmonary function in children with cystic fibrosis.

    PubMed

    Wells, Greg D; Wilkes, Donna L; Schneiderman, Jane E; Thompson, Sara; Coates, Allan L; Ratjen, Felix

    2014-09-01

    Although peak aerobic capacity (VO(2peak)) has been linked to outcome in patients with cystic fibrosis (CF), measuring is time consuming, and requires expensive equipment and expertise that is not readily available in all centers. Other fitness parameters such as peak anaerobic power, measures of power and strength may be simpler to deliver in the clinic. The relationship between these measures and established outcomes such as forced expiratory volume in one second (FEV(1)) and peak aerobic power (VO(2peak)) in CF remains unclear. Therefore we evaluated (a) aerobic fitness, (b) anaerobic fitness, and (c) upper and lower body muscle strength to determine their relationship to FEV(1) and VO(2peak) in children with CF. Eighty-two patients (7-18 years) with CF (40 female) from the CF clinic at The Hospital for Sick Children in Toronto performed a maximal incremental cycling test to exhaustion. Anaerobic power (W) for 10 and 30 sec cycling trials as well as vertical jump (VJ) and hand grip strength (HG) were compared to FEV(1) and VO(2peak). Absolute VO(2peak) (R(2)  = 0.16, P < 0.001), anaerobic power (R(2)  = 0.21, P < 0.001), and hand grip strength (R(2)  = 0.10, P = 0.003) were significantly correlated to lung function whereas measures of explosive lower body strength (VJ) were not. Anaerobic power (R(2)  = 0.16, P = 0.001) and hand grip strength (R(2)  = 0.08, P = 0.01) were related to VO(2peak). Vertical jump was correlated with VO(2peak) (R(2)  = 0.29, P < 0.001) but not FEV(1). Simple fitness tests such as hand grip strength and anaerobic cycle tests may be useful indicators of lung health and fitness. © 2013 Wiley Periodicals, Inc.

  1. Occupation, smoking, and chronic obstructive respiratory disorders: a cross sectional study in an industrial area of Catalonia, Spain

    PubMed Central

    Jaén, Ángeles; Zock, Jan Paul; Kogevinas, Manolis; Ferrer, Antonio; Marín, Albert

    2006-01-01

    Background Few studies have investigated the independent effects of occupational exposures and smoking on chronic bronchitis and airflow obstruction. We assessed the association between lifetime occupational exposures and airflow obstruction in a cross-sectional survey in an urban-industrial area of Catalonia, Spain. Methods We interviewed 576 subjects of both sexes aged 20–70 years (response rate 80%) randomly selected from census rolls, using the ATS questionnaire. Forced spirometry was performed by 497 subjects according to ATS normative. Results Lifetime occupational exposure to dust, gases or fumes was reported by 52% of the subjects (63% in men, 41% in women). Textile industry was the most frequently reported job in relation to these exposures (39%). Chronic cough, expectoration and wheeze were more prevalent in exposed subjects with odds ratios ranging from 1.7 to 2.0 being highest among never-smokers (2.1 to 4.3). Lung function differences between exposed and unexposed subjects were dependent on duration of exposure, but not on smoking habits. Subjects exposed more than 15 years to dusts, gases or fumes had lower lung function values (FEV1 -80 ml, 95% confidence interval (CI) -186 to 26; MMEF -163 ml, CI -397 to 71; FEV1/FVC ratio -1.7%, CI -3.3 to -0.2) than non-exposed. Conclusion Chronic bronchitis symptoms and airflow obstruction are associated with occupational exposures in a population with a high employment in the textile industry. Lung function impairment was related to the duration of occupational exposure, being independent of the effect of smoking. PMID:16476167

  2. Epidemiological study of respiratory disease in workers exposed to polyvinylchloride dust.

    PubMed Central

    Soutar, C A; Copland, L H; Thornley, P E; Hurley, J F; Ottery, J; Adams, W G; Bennett, B

    1980-01-01

    The respiratory health of workers exposed to polyvinylchloride (PVC) dust has been investigated in 818 men sampled from the work force of a factory manufacturing PVC. In a cross-sectional survey, the lung function and prevalences of respiratory symptoms and chest radiographic abnormalities were compared with estimates of individual PVC dust exposures based on detailed occupational histories and current measurements of respirable PVC dust. Complaints of slight exertional dyspnoea were associated with PVC dust exposure, though age and smoking effects were much stronger. The forced expired volume in one second (FEV1) and forced vital capacity (FVC) were inversely related to dust exposure after age, height, and smoking effects had been taken into account. This effect was seen principally in cigarette smokers, and there was suggestive evidence that PVC dust exposure and cigarette smoking interacted in the reduction of FEV1 and FVC. Gas transfer factor was not related to dust exposure. The chest radiographs were read according to the ILO U/C classification by three experienced readers. One reader recorded a low prevalence of small rounded opacities, and these were not related to age or dust exposure. Another reader recorded a higher prevalence of small rounded opacities category 0/1 or more, and these were related to age but not to dust exposure. The third reader recorded the highest prevalence of small rounded opacities (though none greater than category 1/1), and these were independently related both to age and to PVC dust exposure, indicating an effect of PVC dust on the appearance of the chest radiography. These appearances were so slight that only the higher sensitivity of this reader in the interpretation of profusion of small rounded opacities on the ILO U/C scale enabled detection of this effect of PVC dust. In conclusion, exposure to PVC dust is associated with some deterioration of lung function, slight abnormalities of the chest radiograph, and complaints of slight dyspnoea. The mean decline in FEV1 associated with the average dust exposure experienced in the study was small, though some of the men with higher dust exposures may have suffered clinically important loss of lung function as a result of their occupation. PMID:7444838

  3. Analysis of the Plasma Proteome in COPD: Novel Low Abundance Proteins Reflect the Severity of Lung Remodeling

    PubMed Central

    Merali, Salim; Barrero, Carlos A.; Bowler, Russell P.; Chen, Diane Er; Criner, Gerard; Braverman, Alan; Litwin, Samuel; Yeung, Anthony; Kelsen, Steven G.

    2015-01-01

    The search for COPD biomarkers has largely employed a targeted approach that focuses on plasma proteins involved in the systemic inflammatory response and in lung injury and repair. This proof of concept study was designed to test the idea that an open, unbiased, in-depth proteomics approach could identify novel, low abundance plasma proteins i.e., ng/mL concentration, which could serve as potential biomarkers. Differentially expressed proteins were identified in a discovery group with severe COPD (FEV1 <45% predicted; n = 10). Subjects with normal lung function matched for age, sex, ethnicity and smoking history served as controls (n = 10). Pooled plasma from each group was exhaustively immunodepleted of abundant proteins, d separated by 1-D gel electrophoresis and extensively fractionated prior to LC-tandem mass spectroscopy (GeLC-MS). Thirty one differentially expressed proteins were identified in the discovery group including markers of lung defense against oxidant stress, alveolar macrophage activation, and lung tissue injury and repair. Four of the 31 proteins (i.e., GRP78, soluble CD163, IL1AP and MSPT9) were measured in a separate verification group of 80 subjects with varying COPD severity by immunoassay. All 4 were significantly altered in COPD and 2 (GRP78 and soluble CD163) correlated with both FEV1 and the extent of emphysema. In-depth, plasma proteomic analysis identified a group of novel, differentially expressed, low abundance proteins that reflect known pathogenic mechanisms and the severity of lung remodeling in COPD. These proteins may also prove useful as COPD biomarkers. PMID:24111704

  4. Analysis of the plasma proteome in COPD: Novel low abundance proteins reflect the severity of lung remodeling.

    PubMed

    Merali, Salim; Barrero, Carlos A; Bowler, Russell P; Chen, Diane Er; Criner, Gerard; Braverman, Alan; Litwin, Samuel; Yeung, Anthony; Kelsen, Steven G

    2014-04-01

    The search for COPD biomarkers has largely employed a targeted approach that focuses on plasma proteins involved in the systemic inflammatory response and in lung injury and repair. This proof of concept study was designed to test the idea that an open, unbiased, in-depth proteomics approach could identify novel, low abundance plasma proteins i.e., ng/mL concentration, which could serve as potential biomarkers. Differentially expressed proteins were identified in a discovery group with severe COPD (FEV1 <45% predicted; n = 10). Subjects with normal lung function matched for age, sex, ethnicity and smoking history served as controls (n = 10). Pooled plasma from each group was exhaustively immunodepleted of abundant proteins, d separated by 1-D gel electrophoresis and extensively fractionated prior to LC-tandem mass spectroscopy (GeLC-MS). Thirty one differentially expressed proteins were identified in the discovery group including markers of lung defense against oxidant stress, alveolar macrophage activation, and lung tissue injury and repair. Four of the 31 proteins (i.e., GRP78, soluble CD163, IL1AP and MSPT9) were measured in a separate verification group of 80 subjects with varying COPD severity by immunoassay. All 4 were significantly altered in COPD and 2 (GRP78 and soluble CD163) correlated with both FEV1 and the extent of emphysema. In-depth, plasma proteomic analysis identified a group of novel, differentially expressed, low abundance proteins that reflect known pathogenic mechanisms and the severity of lung remodeling in COPD. These proteins may also prove useful as COPD biomarkers.

  5. Lessons learned from a randomized trial of airway secretion clearance techniques in cystic fibrosis

    PubMed Central

    Sontag, Marci K.; Quittner, Alexandra L.; Modi, Avani C.; Koenig, Joni M.; Giles, Don; Oermann, Christopher M.; Konstan, Michael W.; Castile, Robert; Accurso, Frank J.

    2014-01-01

    Rationale Airway secretion clearance therapies are a cornerstone of cystic fibrosis care, however longitudinal comparative studies are rare. Our objectives were to compare three therapies [postural drainage and percussion: (postural drainage), flutter device, and high frequency chest wall oscillation: (vest)], by studying 1) change in pulmonary function; 2) time to need for IV antibiotics, 3) use of pulmonary therapies, 4) adherence to treatment, 5) treatment satisfaction, and 6) quality of life. Methods Participants were randomly assigned to one of three therapies twice daily. Clinical outcomes were assessed quarterly over 3 years. Results Enrollment goals were not met, and withdrawal rates were high, especially in postural drainage (51%) and flutter device (26%), compared to vest (9%), resulting in early termination. FEV1 decline, time to need IV antibiotics, and other pulmonary therapies were not different. The annual FEF25–75% predicted rate of decline was greater in those using vest (p=0.02). Adherence was not significantly different (p=0.09). Overall treatment satisfaction was higher in vest and flutter device than in postural drainage (p<0.05). Health-related quality of life was not different. The rate of FEV1 decline was 1.23% predicted/year. Conclusions The study was ended early due to dropout and smaller than expected decline in FEV1. Patients were more satisfied with vest and flutter device. The longitudinal decline in FEF25–75% was faster in vest; we found no other difference in lung function decline, taken together this warrants further study. The slow decline in FEV1 illustrates the difficulty with FEV1 decline as a clinical trial outcome. PMID:20146387

  6. 6.6-hour inhalation of ozone concentrations from 60 to 87 parts per billion in healthy humans.

    PubMed

    Schelegle, Edward S; Morales, Christopher A; Walby, William F; Marion, Susan; Allen, Roblee P

    2009-08-01

    Identification of the minimal ozone (O(3)) concentration and/or dose that induces measurable lung function decrements in humans is considered in the risk assessment leading to establishing an appropriate National Ambient Air Quality Standard for O(3) that protects public health. To identify and/or predict the minimal mean O(3) concentration that produces a decrement in FEV(1) and symptoms in healthy individuals completing 6.6-hour exposure protocols. Pulmonary function and subjective symptoms were measured in 31 healthy adults (18-25 yr, male and female, nonsmokers) who completed five 6.6-hour chamber exposures: filtered air and four variable hourly patterns with mean O(3) concentrations of 60, 70, 80, and 87 parts per billion (ppb). Compared with filtered air, statistically significant decrements in FEV(1) and increases in total subjective symptoms scores (P < 0.05) were measured after exposure to mean concentrations of 70, 80, and 87 ppb O(3). The mean percent change in FEV(1) (+/-standard error) at the end of each protocol was 0.80 +/- 0.90, -2.72 +/- 1.48, -5.34 +/- 1.42, -7.02 +/- 1.60, and -11.42 +/- 2.20% for exposure to filtered air and 60, 70, 80, and 87 ppb O(3), respectively. Inhalation of 70 ppb O(3) for 6.6 hours, a concentration below the current 8-hour National Ambient Air Quality Standard of 75 ppb, is sufficient to induce statistically significant decrements in FEV(1) in healthy young adults.

  7. Modulation of Lung Function by Increased Nitric Oxide Production

    PubMed Central

    Yadav, Ram Lochan; Yadav, Prakash Kumar

    2017-01-01

    Introduction Cigarette smoking reduces endogenous Nitric Oxide (NO) production by reducing Nitric Oxide Synthase (NOS) activity, which is one of the probable reason for increased rate of pulmonary diseases in smokers. Nitric oxide/oxygen blends are used in critical care to promote capillary and pulmonary dilation to treat several pulmonary vascular diseases. Among several supplements, the highest NOS activation has been proved for garlic with its unique mechanism of action. Aim To investigate the effect of dietary supplementation of NO producing garlic on pulmonary function of smokers. Materials and Methods The study was conducted on 40 healthy non-smoker (Group A) and 40 chronic smoker (Group B) males with matched age, height and weight. The pulmonary function tests- Forced Vital Capacity (FVC), Forced Expiratory Volume in one second (FEV1), FEV1/FVC ratio and Peak Expiratory Flow Rate (PEFR) were performed in non-smokers (Group A), smokers (Group B) and smokers after supplementation of approximately 4 gm of raw garlic (2 garlic cloves) per day for three months (Group C). Endogenous NO production was studied in smokers before and after garlic supplementation and in non-smokers without supplementation. The data obtained were compared between the groups using unpaired student’s t-test. The p-value considered significant at <0.05. Results Our results showed that FVC, FEV1, FEV1/FVC ratio and PEFR were reduced significantly along with a significant decreased NOS activity among smokers (Group B) when compared with non-smokers (Group A). Garlic supplementation significantly improved the pulmonary function tests in Group C in comparison to Group B by increasing NOS activity. Conclusion Dietary supplementation of garlic, which might be by increasing NOS activity, has significantly improved pulmonary functions in smokers. PMID:28764150

  8. Improved pulmonary function in working divers breathing nitrox at shallow depths

    NASA Technical Reports Server (NTRS)

    Fitzpatrick, Daniel T.; Conkin, Johnny

    2003-01-01

    INTRODUCTION: There is limited data about the long-term pulmonary effects of nitrox use in divers at shallow depths. This study examined changes in pulmonary function in a cohort of working divers breathing a 46% oxygen enriched mixture while diving at depths less than 12 m. METHODS: A total of 43 working divers from the Neutral Buoyancy Laboratory (NBL), NASA-Johnson Space Center completed a questionnaire providing information on diving history prior to NBL employment, diving history outside the NBL since employment, and smoking history. Cumulative dive hours were obtained from the NBL dive-time database. Medical records were reviewed to obtain the diver's height, weight, and pulmonary function measurements from initial pre-dive, first year and third year annual medical examinations. RESULTS: The initial forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1) were greater than predicted, 104% and 102%, respectively. After 3 yr of diving at the NBL, both the FVC and FEV1 showed a significant (p < 0.01) increase of 6.3% and 5.5%, respectively. There were no significant changes in peak expiratory flow (PEF), forced mid-expiratory flow rate (FEF(25-75%)), and forced expiratory flow rates at 25%, 50%, and 75% of FVC expired (FEF25%, FEF50%, FEF75%). Cumulative NBL dive hours was the only contributing variable found to be significantly associated with both FVC and FEV1 at 1 and 3 yr. CONCLUSIONS: NBL divers initially belong to a select group with larger than predicted lung volumes. Regular diving with nitrox at shallow depths over a 3-yr period did not impair pulmonary function. Improvements in FVC and FEV1 were primarily due to a training effect.

  9. Air Pollution, Airway Inflammation, and Lung Function in a Cohort Study of Mexico City Schoolchildren

    PubMed Central

    Barraza-Villarreal, Albino; Sunyer, Jordi; Hernandez-Cadena, Leticia; Escamilla-Nuñez, Maria Consuelo; Sienra-Monge, Juan Jose; Ramírez-Aguilar, Matiana; Cortez-Lugo, Marlene; Holguin, Fernando; Diaz-Sánchez, David; Olin, Anna Carin; Romieu, Isabelle

    2008-01-01

    Background The biological mechanisms involved in inflammatory response to air pollution are not clearly understood. Objective In this study we assessed the association of short-term air pollutant exposure with inflammatory markers and lung function. Methods We studied a cohort of 158 asthmatic and 50 nonasthmatic school-age children, followed an average of 22 weeks. We conducted spirometric tests, measurements of fractional exhaled nitric oxide (FeNO), interleukin-8 (IL-8) in nasal lavage, and pH of exhaled breath condensate every 15 days during follow-up. Data were analyzed using linear mixed-effects models. Results An increase of 17.5 μg/m3 in the 8-hr moving average of PM2.5 levels (interquartile range) was associated with a 1.08-ppb increase in FeNO [95% confidence interval (CI), 1.01–1.16] and a 1.07-pg/mL increase in IL-8 (95% CI 0.98–1.19) in asthmatic children and a 1.16 pg/ml increase in IL-8 (95% CI, 1.00–1.36) in nonasthmatic children. The 5-day accumulated average of exposure to particulate matter < 2.5 μm in aerodynamic diamter (PM2.5) was significantly inversely associated with forced expiratory volume in 1 sec (FEV1) (p = 0.048) and forced vital capacity (FVC) (p = 0.012) in asthmatic children and with FVC (p = 0.021) in nonasthmatic children. FeNO and FEV1 were inversely associated (p = 0.005) in asthmatic children. Conclusions Exposure to PM2.5 resulted in acute airway inflammation and decrease in lung function in both asthmatic and nonasthmatic children. PMID:18560490

  10. Influence of heart failure on resting lung volumes in patients with COPD

    PubMed Central

    de Souza, Aline Soares; Sperandio, Priscila Abreu; Mazzuco, Adriana; Alencar, Maria Clara; Arbex, Flávio Ferlin; de Oliveira, Mayron Faria; O'Donnell, Denis Eunan; Neder, José Alberto

    2016-01-01

    ABSTRACT Objective: To evaluate the influence of chronic heart failure (CHF) on resting lung volumes in patients with COPD, i.e., inspiratory fraction-inspiratory capacity (IC)/TLC-and relative inspiratory reserve-[1 − (end-inspiratory lung volume/TLC)]. Methods: This was a prospective study involving 56 patients with COPD-24 (23 males/1 female) with COPD+CHF and 32 (28 males/4 females) with COPD only-who, after careful clinical stabilization, underwent spirometry (with forced and slow maneuvers) and whole-body plethysmography. Results: Although FEV1, as well as the FEV1/FVC and FEV1/slow vital capacity ratios, were higher in the COPD+CHF group than in the COPD group, all major "static" volumes-RV, functional residual capacity (FRC), and TLC-were lower in the former group (p < 0.05). There was a greater reduction in FRC than in RV, resulting in the expiratory reserve volume being lower in the COPD+CHF group than in the COPD group. There were relatively proportional reductions in FRC and TLC in the two groups; therefore, IC was also comparable. Consequently, the inspiratory fraction was higher in the COPD+CHF group than in the COPD group (0.42 ± 0.10 vs. 0.36 ± 0.10; p < 0.05). Although the tidal volume/IC ratio was higher in the COPD+CHF group, the relative inspiratory reserve was remarkably similar between the two groups (0.35 ± 0.09 vs. 0.44 ± 0.14; p < 0.05). Conclusions: Despite the restrictive effects of CHF, patients with COPD+CHF have relatively higher inspiratory limits (a greater inspiratory fraction). However, those patients use only a part of those limits, probably in order to avoid critical reductions in inspiratory reserve and increases in elastic recoil. PMID:27832235

  11. Pulmonary dysfunctions, oxidative stress and DNA damage in brick kiln workers.

    PubMed

    Kaushik, R; Khaliq, F; Subramaneyaan, M; Ahmed, R S

    2012-11-01

    Brick kilns in the suburban areas in developing countries pose a big threat to the environment and hence the health of their workers and people residing around them. The present study was planned to assess the lung functions, oxidative stress parameters and DNA damage in brick kiln workers. A total of 31 male subjects working in brick kiln, and 32 age, sex and socioeconomic status matched controls were included in the study. The lung volumes, capacities and flow rates, namely, forced expiratory volume in first second (FEV(1)), forced vital capacity (FVC), FEV(1)/FVC, expiratory reserve volume, inspiratory capacity (IC), maximal expiratory flow when 50% of FVC is remaining to be expired, maximum voluntary ventilation, peak expiratory flow rate and vital capacity were significantly decreased in the brick kiln workers. Increased oxidative stress as evidenced by increased malonedialdehyde levels and reduced glutathione content, glutathione S-transferase activity and ferric reducing ability of plasma were observed in the study group when compared with controls. Our results indicate a significant correlation between oxidative stress parameters and pulmonary dysfunction, which may be due to silica-induced oxidative stress and resulting lung damage.

  12. Useful marker of oscillatory lung function in methacholine challenge test-comparison of reactance and resistance with dose-response slope.

    PubMed

    Yoon, Jung Won; Shin, Youn Ho; Jee, Hye Mi; Chang, Sun Jung; Baek, Ji Hyeon; Choi, Sun Hee; Kim, Hyeong Yun; Han, Man Yong

    2014-06-01

    There are few studies focusing on the comparison of resistance (Rrs) and reactance (Xrs) in impulse oscillometry system (IOS) in the bronchial challenge test using dose-response slope (DRS), a quantitative index of bronchial hyperresponsiveness. We conducted a case-control study of 144 asthmatic and 218 non-asthmatic children to compare the diagnostic accuracy of two-point linear DRS for FEV1 , Rrs5 , and Xrs5 (DRS_FEV1 , DRS_Rrs5 , and DRS_Xrs5 ) and assessed various diagnostic cut-off points of provocation concentrations (PC) using receiver operating characteristic (ROC) curves. DRS_FEV1 had a stronger correlation with DRS_Xrs5 (r = 0.739, P < 0.001) than with DRS_Rrs5 (r = 0.652, P < 0.001) and the area under the ROC curves of DRS_Xrs5 (0.737) was similar to that of DRS_FEV1 (0.732) and higher than that of DRS_Rrs5 (0.668). The area under the ROC curves in order of greater value was as follows: absolute change of Xrs5 (Abs_Xrs5 ) (0.759) > percent change of FEV1 (Pch_FEV1 ) (0.735) > Pch_Xrs5 (0.727) > Abs_Rrs5 (0.690) > Pch_Rrs5 (0.630). PC78 _Xrs5 and PC0.17 _Xrs5 of IOS showed considerably good sensitivity and specificity comparable to those of PC20 _FEV1 by spirometry. Additional 18 (13%) children who showed normal spirometric measures were identified as asthmatics with the use of IOS. The utility of the DRS_Xrs5 to differentiate asthmatics from controls was comparable to that of the DRS_FEV1 and better than that of the DRS_Rrs5 . In addition, IOS could detect additional asthmatic patients who did not show positive responses in spirometry. © 2013 Wiley Periodicals, Inc.

  13. Poor sleep quality has an adverse effect on childhood asthma control and lung function measures.

    PubMed

    Sheen, Youn Ho; Choi, Sun Hee; Jang, Sun Jung; Baek, Ji Hyeon; Jee, Hye Mi; Kim, Mi Ae; Chae, Kyu Young; Han, Man Yong

    2017-08-01

    It is unclear as to whether sleep respiratory breathing disorder (SRBD) is a risk factor for uncontrolled asthma in children. The aim of this study was therefore to investigate whether SRBD may have an adverse effect on childhood asthma control and lung function measures. This was a cross-sectional study of 220 children with well-controlled (n = 108), partly controlled (n = 92), and uncontrolled asthma (n = 20) according to the Global Initiative for Asthma guideline. SRBD was assessed using the Pediatric Sleep Questionnaire (PSQ). The association of SRBD with partly controlled/uncontrolled asthma was investigated on multivariate logistic regression analysis. Of 220 children with asthma, 43 (19.6%) had SRBD: well-controlled, 16.7% (18/108); partly controlled, 21.7% (20/92); and uncontrolled, 25.0% (5/20; P = 0.54). There was a significant difference in forced expiratory volume in 1 s/forced vital capacity (FEV 1 /FVC; P = 0.007) and childhood asthma control test (C-ACT) score (P < 0.001) according to asthma control status, but not in PSQ score (P = 0.18). Children with obstructive sleep apnea (PSQ >0.33) had a lower C-ACT score compared with controls (PSQ ≤0.33; 19.6 ± 5.1 vs 22.0 ± 4.2, P = 0.002). PSQ score was negatively correlated with FEV 1 /FVC (r = -0.16, P = 0.02). On multivariate logistic regression analysis, high PSQ score increased the odds of having partly controlled/uncontrolled asthma by 9.12 (95% CI: 1.04-79.72, P = 0.046) after adjusting for confounding factors. SRBD is an independent risk factor for partly controlled/uncontrolled asthma and has an adverse effect on lung function measures in children. Further research is warranted to determine whether the improvement of sleep quality may also enhance level of asthma control and lung function in children. © 2017 Japan Pediatric Society.

  14. A follow-up study of airway symptoms and lung function among residents and workers 5.5 years after an oil tank explosion.

    PubMed

    Granslo, Jens-Tore; Bråtveit, Magne; Hollund, Bjørg Eli; Lygre, Stein Håkon Låstad; Svanes, Cecilie; Moen, Bente Elisabeth

    2017-01-17

    Assess if people who lived or worked in an area polluted after an oil tank explosion had persistent respiratory health impairment as compared to a non-exposed population 5.5 years after the event. A follow-up study 5.5 years after the explosion, 330 persons aged 18-67 years, compared lung function, lung function decline and airway symptoms among exposed persons (residents <6 km from the accident site or working in the industrial harbour at the time of the explosion) with a non-exposed group (residence >20 km away). Also men in the exposed group who had participated in accident related tasks (firefighting or clean-up of pollution) were compared with men who did not. Data were analysed using Poisson regression, adjusted for smoking, occupational exposure, atopy and age. Exposed men who had participated in accident related tasks had higher prevalence of lower airway symptoms after 5.5 years (n = 24 [73%]) than non-exposed men (28 [48%]), (adjusted relative risk 1.51 [95% confidence interval 1.07, 2.14]). Among men who participated in accident related tasks FEV 1 decline was 48 mL per year, and 12 mL among men who did not (adjusted difference -34 mL per year [-67 mL, -1 mL]), and at follow-up FEV 1 /FVC ratio was 71.4 and 74.2% respectively, (adjusted difference -3.0% [-6.0, 0.0%]). Residents and workers had more airway symptoms and impaired lung function 5.5 years after an oil tank explosion, most significant for a group of men engaged in firefighting and clean-up of pollution after the accident. Public health authorities should be aware of long-term consequences after such accidents.

  15. Self-reported exercise and longitudinal outcomes in cystic fibrosis: a retrospective cohort study.

    PubMed

    Collaco, Joseph M; Blackman, Scott M; Raraigh, Karen S; Morrow, Christopher B; Cutting, Garry R; Paranjape, Shruti M

    2014-10-06

    Cystic fibrosis (CF) is characterized by recurrent respiratory infections and progressive lung disease. Whereas exercise may contribute to preserving lung function, its benefit is difficult to ascertain given the selection bias of healthier patients being more predisposed to exercise. Our objective was to examine the role of self-reported exercise with longitudinal lung function and body mass index (BMI) measures in CF. A total of 1038 subjects with CF were recruited through the U.S. CF Twin-Sibling Study. Questionnaires were used to determine exercise habits. Questionnaires, chart review, and U.S. CF Foundation Patient Registry data were used to track outcomes. Within the study sample 75% of subjects self-reported regular exercise. Exercise was associated with an older age of diagnosis (p = 0.002), older age at the time of ascertainment (p < 0.001), and higher baseline FEV1 (p = 0.001), but not CFTR genotype (p = 0.64) or exocrine pancreatic function (p = 0.19). In adjusted mixed models, exercise was associated with both a reduced decline in FEV1 (p < 0.001) and BMI Z-score (p = 0.001) for adults, but not children aged 10-17 years old. In our retrospective study, self-reported exercise was associated with improved longitudinal nutritional and pulmonary outcomes in cystic fibrosis for adults. Although prospective studies are needed to confirm these associations, programs to promote regular exercise among individuals with cystic fibrosis would be beneficial.

  16. Correlation and Agreement of Handheld Spirometry with Laboratory Spirometry in Allogeneic Hematopoietic Cell Transplant Recipients

    PubMed Central

    Cheng, Guang-Shing; Campbell, Angela P.; Xie, Hu; Stednick, Zach; Callais, Cheryl; Leisenring, Wendy M.; Englund, Janet A.; Chien, Jason W.; Boeckh, Michael

    2016-01-01

    BACKGROUND Early detection of subclinical lung function decline may help identify allogeneic hematopoietic cell transplantation (HCT) recipients who are at increased risk for late non-infectious pulmonary complications including bronchiolitis obliterans syndrome (BOS). We evaluated the use of handheld spirometry in this population. METHODS Allogeneic HCT recipients enrolled in a single center observational trial performed weekly spirometry with a handheld spirometer for one year after transplantation. Participants performed pulmonary function tests in an outpatient laboratory setting at 3 time points: pre-transplant, day 80 and 1 year post-transplant. Correlation between the two methods was assessed by Pearson and Spearman correlations; agreement was assessed using Bland-Altman plots. RESULTS A total of 437 subjects had evaluable pulmonary function tests. Correlation for FEV1 was r=0.954 (p<.0001) at day 80 and r=0.931 (p<.0001) at 1 year when the handheld and laboratory tests were performed within one day of each other. Correlation for handheld FEV6 with laboratory FVC was r=0.914 (p<.0001) at day 80 and r=0.826 (p<.0001) at 1 year. The bias, or the mean difference (handheld minus laboratory) for FEV1 at day 80 and 1 year was −0.13L (−0.63, 0.37) and −0.10L (−0.77, 0.56), respectively. FEV6 showed greater bias at day 80 [−0.51L (−1.44, 0.42)] and 1 year [−0.40L (−1.81, 1.01)]. CONCLUSIONS Handheld spirometry correlated well with laboratory spirometry after allogeneic HCT and may be useful for self-monitoring of patients for early identification of airflow obstruction. PMID:26748162

  17. Circulating RNA transcripts identify therapeutic response in cystic fibrosis lung disease.

    PubMed

    Saavedra, Milene T; Hughes, Grant J; Sanders, Linda A; Carr, Michelle; Rodman, David M; Coldren, Christopher D; Geraci, Mark W; Sagel, Scott D; Accurso, Frank J; West, James; Nick, Jerry A

    2008-11-01

    Circulating leukocyte RNA transcripts are systemic markers of inflammation, which have not been studied in cystic fibrosis (CF) lung disease. Although the standard assessment of pulmonary treatment response is FEV(1), a measure of airflow limitation, the lack of systemic markers to reflect changes in lung inflammation critically limits the testing of proposed therapeutics. We sought to prospectively identify and validate peripheral blood leukocyte genes that could mark resolution of pulmonary infection and inflammation using a model by which RNA transcripts could increase the predictive value of spirometry. Peripheral blood mononuclear cells were isolated from 10 patients with CF and acute pulmonary exacerbations before and after therapy. RNA expression profiling revealed that 10 genes significantly changed with treatment when compared with matched non-CF and control subjects with stable CF to establish baseline transcript abundance. Peripheral blood mononuclear cell RNA transcripts were prospectively validated, using real-time polymerase chain reaction amplification, in an independent cohort of acutely ill patients with CF (n = 14). Patients who responded to therapy were analyzed using general estimating equations and multiple logistic regression, such that changes in FEV(1)% predicted were regressed with transcript changes. Three genes, CD64, ADAM9, and CD36, were significant and independent predictors of a therapeutic response beyond that of FEV(1) alone (P < 0.05). In both cohorts, receiver operating characteristic analysis revealed greater accuracy when genes were combined with FEV(1). Circulating mononuclear cell transcripts characterize a response to the treatment of pulmonary exacerbations. Even in small patient cohorts, changes in gene expression in conjunction with FEV(1) may enhance current outcomes measures for treatment response.

  18. Accumulating physical activity in at least 10-minute bouts predicts better lung function after 3-years in adults with cystic fibrosis.

    PubMed

    Cox, Narelle S; Alison, Jennifer A; Button, Brenda M; Wilson, John W; Morton, Judith M; Holland, Anne E

    2018-04-01

    Achieving physical activity guidelines by undertaking multiple bouts of moderate-vigorous physical activity ≥10 min duration, but not shorter periods of activity, was independently associated with less decline in FEV 1 over 3 years among adults with CF http://ow.ly/yk6930ivCV8.

  19. Indoor Air Quality and Respiratory Health among Malay Preschool Children in Selangor.

    PubMed

    Rawi, Nur Azwani Mohd Nor; Jalaludin, Juliana; Chua, Poh Choo

    2015-01-01

    Indoor air quality (IAQ) has been the object of several studies due to its adverse health effects on children. Methods. A cross-sectional comparative study was carried out among Malay children in Balakong (2 studied preschools) and Bangi (2 comparative preschools), Selangor, with the aims of determining IAQ and its association with respiratory health. 61 and 50 children aged 5-6 years were selected as studied and comparative groups. A questionnaire was used to obtain an exposure history and respiratory symptoms. Lung function test was carried out. IAQ parameters obtained include indoor concentration of particulate matter (PM), volatile organic compounds (VOCs), carbon monoxide (CO), carbon dioxide (CO2), temperature, air velocity (AV), and relative humidity. Results. There was a significant difference between IAQ in studied and comparative preschools for all parameters measured (P < 0.001) except for CO2 and AV. Studied preschools had higher PM and CO concentration. FVC, FEV1, FVC% and FEV1% predicted values were significantly lower among studied group. Exposures to PM, VOCs, and CO were associated with wheezing. Conclusion. The finding concluded that exposures to poor IAQ might increase the risk of getting lung function abnormality and respiratory problems among study respondents.

  20. Indoor Air Quality and Respiratory Health among Malay Preschool Children in Selangor

    PubMed Central

    Chua, Poh Choo

    2015-01-01

    Indoor air quality (IAQ) has been the object of several studies due to its adverse health effects on children. Methods. A cross-sectional comparative study was carried out among Malay children in Balakong (2 studied preschools) and Bangi (2 comparative preschools), Selangor, with the aims of determining IAQ and its association with respiratory health. 61 and 50 children aged 5-6 years were selected as studied and comparative groups. A questionnaire was used to obtain an exposure history and respiratory symptoms. Lung function test was carried out. IAQ parameters obtained include indoor concentration of particulate matter (PM), volatile organic compounds (VOCs), carbon monoxide (CO), carbon dioxide (CO2), temperature, air velocity (AV), and relative humidity. Results. There was a significant difference between IAQ in studied and comparative preschools for all parameters measured (P < 0.001) except for CO2 and AV. Studied preschools had higher PM and CO concentration. FVC, FEV1, FVC% and FEV1% predicted values were significantly lower among studied group. Exposures to PM, VOCs, and CO were associated with wheezing. Conclusion. The finding concluded that exposures to poor IAQ might increase the risk of getting lung function abnormality and respiratory problems among study respondents. PMID:25984527

Top