TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (HP9000 SERIES 700/800 VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.
TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (IBM RS/6000 VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.
TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (SUN4 VERSION WITH MOTIF)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.
TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (SILICON GRAPHICS VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.
TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (SUN4 VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.
TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (DEC RISC ULTRIX VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.
TAE+ 5.1 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.1 (HP9000 SERIES 300/400 VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System, Version 11 Release 4, and the Open Software Foundation's Motif. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is expected to be available on media suitable for seven different machine platforms: 1) DEC VAX computers running VMS (TK50 cartridge in VAX BACKUP format), 2) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), 3) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), 4) HP9000 Series 300/400 computers running HP-UX (.25 inch HP-preformatted tape cartridge in UNIX tar format), 5) HP9000 Series 700 computers running HP-UX (HP 4mm DDS DAT tape cartridge in UNIX tar format), 6) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and 7) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2.
TAE+ 5.1 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.1 (VAX VMS VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System, Version 11 Release 4, and the Open Software Foundation's Motif. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is expected to be available on media suitable for seven different machine platforms: 1) DEC VAX computers running VMS (TK50 cartridge in VAX BACKUP format), 2) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), 3) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), 4) HP9000 Series 300/400 computers running HP-UX (.25 inch HP-preformatted tape cartridge in UNIX tar format), 5) HP9000 Series 700 computers running HP-UX (HP 4mm DDS DAT tape cartridge in UNIX tar format), 6) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and 7) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2.
TAE+ 5.1 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.1 (DEC VAX ULTRIX VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. Data-driven graphical objects such as dials, thermometers, and strip charts are also included. TAE Plus updates the strip chart as the data values change. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. The Silicon Graphics version of TAE Plus now has a font caching scheme and a color caching scheme to make color allocation more efficient. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides an extremely powerful means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System, Version 11 Release 4, and the Open Software Foundation's Motif Toolkit 1.1 or 1.1.1. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus comes with InterViews and idraw, two software packages developed by Stanford University and integrated in TAE Plus. TAE Plus was developed in 1989 and version 5.1 was released in 1991. TAE Plus is currently available on media suitable for eight different machine platforms: 1) DEC VAX computers running VMS 5.3 or higher (TK50 cartridge in VAX BACKUP format), 2) DEC VAXstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 3) DEC RISC workstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 4) HP9000 Series 300/400 computers running HP-UX 8.0 (.25 inch HP-preformatted tape cartridge in UNIX tar format), 5) HP9000 Series 700 computers running HP-UX 8.05 (HP 4mm DDS DAT tape cartridge in UNIX tar format), 6) Sun3 series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), 7) Sun4 (SPARC) series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), and 8) SGI Indigo computers running IRIX 4.0.1 and IRIX/Motif 1.0.1 (.25 inch IRIS tape cartridge in UNIX tar format). An optional Motif Object Code License is available for either Sun version. TAE is a trademark of the National Aeronautics and Space Administration. X Window System is a trademark of the Massachusetts Institute of Technology. Motif is a trademark of the Open Software Foundation. DEC, VAX, VMS, TK50 and ULTRIX are trademarks of Digital Equipment Corporation. HP9000 and HP-UX are trademarks of Hewlett-Packard Co. Sun3, Sun4, SunOS, and SPARC are trademarks of Sun Microsystems, Inc. SGI and IRIS are registered trademarks of Silicon Graphics, Inc.
TAE+ 5.1 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.1 (SUN3 VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. Data-driven graphical objects such as dials, thermometers, and strip charts are also included. TAE Plus updates the strip chart as the data values change. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. The Silicon Graphics version of TAE Plus now has a font caching scheme and a color caching scheme to make color allocation more efficient. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides an extremely powerful means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System, Version 11 Release 4, and the Open Software Foundation's Motif Toolkit 1.1 or 1.1.1. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus comes with InterViews and idraw, two software packages developed by Stanford University and integrated in TAE Plus. TAE Plus was developed in 1989 and version 5.1 was released in 1991. TAE Plus is currently available on media suitable for eight different machine platforms: 1) DEC VAX computers running VMS 5.3 or higher (TK50 cartridge in VAX BACKUP format), 2) DEC VAXstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 3) DEC RISC workstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 4) HP9000 Series 300/400 computers running HP-UX 8.0 (.25 inch HP-preformatted tape cartridge in UNIX tar format), 5) HP9000 Series 700 computers running HP-UX 8.05 (HP 4mm DDS DAT tape cartridge in UNIX tar format), 6) Sun3 series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), 7) Sun4 (SPARC) series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), and 8) SGI Indigo computers running IRIX 4.0.1 and IRIX/Motif 1.0.1 (.25 inch IRIS tape cartridge in UNIX tar format). An optional Motif Object Code License is available for either Sun version. TAE is a trademark of the National Aeronautics and Space Administration. X Window System is a trademark of the Massachusetts Institute of Technology. Motif is a trademark of the Open Software Foundation. DEC, VAX, VMS, TK50 and ULTRIX are trademarks of Digital Equipment Corporation. HP9000 and HP-UX are trademarks of Hewlett-Packard Co. Sun3, Sun4, SunOS, and SPARC are trademarks of Sun Microsystems, Inc. SGI and IRIS are registered trademarks of Silicon Graphics, Inc.
TAE+ 5.1 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.1 (SUN3 VERSION WITH MOTIF)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. Data-driven graphical objects such as dials, thermometers, and strip charts are also included. TAE Plus updates the strip chart as the data values change. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. The Silicon Graphics version of TAE Plus now has a font caching scheme and a color caching scheme to make color allocation more efficient. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides an extremely powerful means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System, Version 11 Release 4, and the Open Software Foundation's Motif Toolkit 1.1 or 1.1.1. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus comes with InterViews and idraw, two software packages developed by Stanford University and integrated in TAE Plus. TAE Plus was developed in 1989 and version 5.1 was released in 1991. TAE Plus is currently available on media suitable for eight different machine platforms: 1) DEC VAX computers running VMS 5.3 or higher (TK50 cartridge in VAX BACKUP format), 2) DEC VAXstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 3) DEC RISC workstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 4) HP9000 Series 300/400 computers running HP-UX 8.0 (.25 inch HP-preformatted tape cartridge in UNIX tar format), 5) HP9000 Series 700 computers running HP-UX 8.05 (HP 4mm DDS DAT tape cartridge in UNIX tar format), 6) Sun3 series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), 7) Sun4 (SPARC) series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), and 8) SGI Indigo computers running IRIX 4.0.1 and IRIX/Motif 1.0.1 (.25 inch IRIS tape cartridge in UNIX tar format). An optional Motif Object Code License is available for either Sun version. TAE is a trademark of the National Aeronautics and Space Administration. X Window System is a trademark of the Massachusetts Institute of Technology. Motif is a trademark of the Open Software Foundation. DEC, VAX, VMS, TK50 and ULTRIX are trademarks of Digital Equipment Corporation. HP9000 and HP-UX are trademarks of Hewlett-Packard Co. Sun3, Sun4, SunOS, and SPARC are trademarks of Sun Microsystems, Inc. SGI and IRIS are registered trademarks of Silicon Graphics, Inc.
NASA Technical Reports Server (NTRS)
Szczur, Martha R.
1993-01-01
The Transportable Applications Environment (TAE) Plus, developed at NASA's Goddard Space Flight Center, is an advanced portable user interface development which simplifies the process of creating and managing complex application graphical user interfaces (GUI's). TAE Plus supports the rapid prototyping of GUI's and allows applications to be ported easily between different platforms. This paper will discuss the capabilities of the TAE Plus tool, and how it makes the job of designing and developing GUI's easier for application developers. TAE Plus is being applied to many types of applications, and this paper discusses how it has been used both within and outside NASA.
NASA Technical Reports Server (NTRS)
Szczur, Martha R.
1991-01-01
The transportable Applications Environment Plus (TAE Plus), developed at the NASA Goddard Space FLight Center, is a portable, What you see is what you get (WYSIWYG) user interface development and management system. Its primary objective is to provide an integrated software environment that allows interactive prototyping and development of graphical user interfaces, as well as management of the user interface within the operational domain. TAE Plus is being applied to many types of applications, and what TAE Plus provides, how the implementation has utilizes state-of-the-art technologies within graphic workstations, and how it has been used both within and without NASA are discussed.
NASA Technical Reports Server (NTRS)
Szczur, Martha R.
1990-01-01
The Transportable Applications Environment Plus (TAE PLUS), developed at NASA's Goddard Space Flight Center, is a portable What You See Is What You Get (WYSIWYG) user interface development and management system. Its primary objective is to provide an integrated software environment that allows interactive prototyping and development that of user interfaces, as well as management of the user interface within the operational domain. Although TAE Plus is applicable to many types of applications, its focus is supporting user interfaces for space applications. This paper discusses what TAE Plus provides and how the implementation has utilized state-of-the-art technologies within graphic workstations, windowing systems and object-oriented programming languages.
NASA Technical Reports Server (NTRS)
Szczur, Martha R.
1991-01-01
The Transportable Applications Environment (TAE) Plus, developed at NASA's Goddard Space Flight Center, is an advanced portable user interface development environment which simplifies the process of creating and managing complex application graphical user interfaces (GUIs), supports prototyping, allows applications to be oported easily between different platforms, and encourages appropriate levels of user interface consistency between applications. This paper discusses the capabilities of the TAE Plus tool, and how it makes the job of designing and developing GUIs easier for the application developers. The paper also explains how tools like TAE Plus provide for reusability and ensure reliability of UI software components, as well as how they aid in the reduction of development and maintenance costs.
NASA Technical Reports Server (NTRS)
Szczur, Martha R.
1989-01-01
The Transportable Applications Environment Plus (TAE Plus), developed by NASA's Goddard Space Flight Center, is a portable User Interface Management System (UIMS), which provides an intuitive WYSIWYG WorkBench for prototyping and designing an application's user interface, integrated with tools for efficiently implementing the designed user interface and effective management of the user interface during an application's active domain. During the development of TAE Plus, many design and implementation decisions were based on the state-of-the-art within graphics workstations, windowing system and object-oriented programming languages. Some of the problems and issues experienced during implementation are discussed. A description of the next development steps planned for TAE Plus is also given.
NASA Technical Reports Server (NTRS)
Szczur, Martha R.
1991-01-01
The Transportable Applications Environment (TAE) Plus, developed at GSFC, is an advanced portable user interface development environment which simplifies the process of creating and managing complex application graphical user interfaces (GUI's), supports prototyping, allows applications to be ported easily between different platforms and encourages appropriate levels of user interface consistency between applications. The following topics are discussed: the capabilities of the TAE Plus tool; how the implementation has utilized state-of-the-art technologies within graphic workstations; and how it has been used both within and outside of NASA.
Takada, Kenji
2016-09-01
New approach for the diagnosis of extractions with neural network machine learning. Seok-Ki Jung and Tae-Woo Kim. Am J Orthod Dentofacial Orthop 2016;149:127-33. Not reported. Mathematical modeling. Copyright © 2016 Elsevier Inc. All rights reserved.
Transportable Applications Environment (TAE) Tenth Users' Conference
NASA Technical Reports Server (NTRS)
Rouff, Chris (Editor); Harris, Elfrieda (Editor); Yeager, Arleen (Editor)
1993-01-01
Conference proceedings are represented in graphic visual-aid form. Presentation and panel discussion topics include user experiences with C++ and Ada; the design and interaction of the user interface; the history and goals of TAE; commercialization and testing of TAE Plus; Computer-Human Interaction Models (CHIMES); data driven objects; item-to-item connections and object dependencies; and integration with other software. There follows a list of conference attendees.
The Transportable Applications Environment - An interactive design-to-production development system
NASA Technical Reports Server (NTRS)
Perkins, Dorothy C.; Howell, David R.; Szczur, Martha R.
1988-01-01
An account is given of the design philosophy and architecture of the Transportable Applications Environment (TAE), an executive program binding a system of applications programs into a single, easily operable whole. TAE simplifies the job of a system developer by furnishing a stable framework for system-building; it also integrates system activities, and cooperates with the host operating system in order to perform such functions as task-scheduling and I/O. The initial TAE human/computer interface supported command and menu interfaces, data displays, parameter-prompting, error-reporting, and online help. Recent extensions support graphics workstations with a window-based, modeless user interface.
NASA Technical Reports Server (NTRS)
1994-01-01
A software management system, originally developed for Goddard Space Flight Center (GSFC) by Century Computing, Inc. has evolved from a menu and command oriented system to a state-of-the art user interface development system supporting high resolution graphics workstations. Transportable Applications Environment (TAE) was initially distributed through COSMIC and backed by a TAE support office at GSFC. In 1993, Century Computing assumed the support and distribution functions and began marketing TAE Plus, the system's latest version. The software is easy to use and does not require programming experience.
NASA Technical Reports Server (NTRS)
Szczur, Martha R.
1992-01-01
The Transportable Applications Environment (TAE) Plus was built to support the construction of graphical user interfaces (GUI's) for highly interactive applications, such as real-time processing systems and scientific analysis systems. It is a general purpose portable tool that includes a 'What You See Is What You Get' WorkBench that allows user interface designers to layout and manipulate windows and interaction objects. The WorkBench includes both user entry objects (e.g., radio buttons, menus) and data-driven objects (e.g., dials, gages, stripcharts), which dynamically change based on values of realtime data. Discussed here is what TAE Plus provides, how the implementation has utilized state-of-the-art technologies within graphic workstations, and how it has been used both within and without NASA.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-18
... Engines GmbH (TAE) TAE 125-02-99 and TAE 125-02-114 Reciprocating Engines AGENCY: Federal Aviation... unsafe condition on an aviation product. The MCAI describes the unsafe condition as: In-flight engine shutdown incidents have been reported on aeroplanes equipped with TAE 125 engines. Preliminary...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-25
..., 2010, or SB No. TM TAE 125-1011 P1, dated June 9, 2010, into any engine. FAA AD Differences (f) This AD... Airworthiness Directives; Thielert Aircraft Engines GmbH (TAE) Models TAE 125-01 and TAE 125-02-99 Reciprocating Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule; request for comments...
Observation of Alpha-Driven TAEs in TFTR
NASA Astrophysics Data System (ADS)
Nazikian, R.; Chang, Z.; Fu, G. Y.; Majeski, R.; Batha, S.; Bell, M.; Budny, R.; Cheng, C. Z.; Darrow, D. S.; Duong, H.; Efthimion, P. C.; Fredrickson, E.; Levinton, F.; Mazzucato, E.; Medley, S.; Taylor, S.; Zweben, G.
1996-11-01
Transient mode activity in the TAE range of frequencies (150-170 kHz) with toroidal mode numbers n=2,3 is observed in reduced magnetic shear DT discharges on TFTR with a fusion power threshold of ~1.5 MW. Mode activity appears 50-100 msec after NBI in discharges with the following machine parameter: B=5.3 T, I=1.6MA, R=260cm, P_NBI=25-28 MW, q(0)>2.0 from MSE and toroidal beta β_T<1%. The elevated q(0) and reduced central shear |s|<0.2 is achieved using a full size plasma startup with delayed NBI. Theoretical calculations using NOVA-K indicate that the combined effect of low shear, low beta and elevated q(0) leads to a very low instability threshold for the alpha-driven TAE with β_α (0) ~ 10-4. This appears to be consistent with experimental observations of mode activity in DT plasmas with β_α ~ 10-4 (determined from TRANSP analysis). Thus far the modes have only been observed on Mirnov coils with fluctuation levels tildeB ~ 1mG. Efforts to determine mode location by perturbing the edge density and inducing strong toroidal velocity shear will be reported, as will efforts to affect mode stability by systematically varying the central safety factor.
LAS - LAND ANALYSIS SYSTEM, VERSION 5.0
NASA Technical Reports Server (NTRS)
Pease, P. B.
1994-01-01
The Land Analysis System (LAS) is an image analysis system designed to manipulate and analyze digital data in raster format and provide the user with a wide spectrum of functions and statistical tools for analysis. LAS offers these features under VMS with optional image display capabilities for IVAS and other display devices as well as the X-Windows environment. LAS provides a flexible framework for algorithm development as well as for the processing and analysis of image data. Users may choose between mouse-driven commands or the traditional command line input mode. LAS functions include supervised and unsupervised image classification, film product generation, geometric registration, image repair, radiometric correction and image statistical analysis. Data files accepted by LAS include formats such as Multi-Spectral Scanner (MSS), Thematic Mapper (TM) and Advanced Very High Resolution Radiometer (AVHRR). The enhanced geometric registration package now includes both image to image and map to map transformations. The over 200 LAS functions fall into image processing scenario categories which include: arithmetic and logical functions, data transformations, fourier transforms, geometric registration, hard copy output, image restoration, intensity transformation, multispectral and statistical analysis, file transfer, tape profiling and file management among others. Internal improvements to the LAS code have eliminated the VAX VMS dependencies and improved overall system performance. The maximum LAS image size has been increased to 20,000 lines by 20,000 samples with a maximum of 256 bands per image. The catalog management system used in earlier versions of LAS has been replaced by a more streamlined and maintenance-free method of file management. This system is not dependent on VAX/VMS and relies on file naming conventions alone to allow the use of identical LAS file names on different operating systems. While the LAS code has been improved, the original capabilities of the system have been preserved. These include maintaining associated image history, session logging, and batch, asynchronous and interactive mode of operation. The LAS application programs are integrated under version 4.1 of an interface called the Transportable Applications Executive (TAE). TAE 4.1 has four modes of user interaction: menu, direct command, tutor (or help), and dynamic tutor. In addition TAE 4.1 allows the operation of LAS functions using mouse-driven commands under the TAE-Facelift environment provided with TAE 4.1. These modes of operation allow users, from the beginner to the expert, to exercise specific application options. LAS is written in C-language and FORTRAN 77 for use with DEC VAX computers running VMS with approximately 16Mb of physical memory. This program runs under TAE 4.1. Since TAE 4.1 is not a current version of TAE, TAE 4.1 is included within the LAS distribution. Approximately 130,000 blocks (65Mb) of disk storage space are necessary to store the source code and files generated by the installation procedure for LAS and 44,000 blocks (22Mb) of disk storage space are necessary for TAE 4.1 installation. The only other dependencies for LAS are the subroutine libraries for the specific display device(s) that will be used with LAS/DMS (e.g. X-Windows and/or IVAS). The standard distribution medium for LAS is a set of two 9track 6250 BPI magnetic tapes in DEC VAX BACKUP format. It is also available on a set of two TK50 tape cartridges in DEC VAX BACKUP format. This program was developed in 1986 and last updated in 1992.
Park, Sangik; Shin, Ji Hoon; Gwon, Dong-Il; Kim, Hyoung Jung; Sung, Kyu-Bo; Yoon, Hyun-Ki; Ko, Gi-Young; Ko, Heung Kyu
2017-07-01
To evaluate outcomes of transcatheter arterial embolization (TAE) for gastric cancer-related gastrointestinal (GI) bleeding and factors associated with successful TAE and improved survival after TAE. This retrospective study included 43 patients (34 men; age 60.6 y ± 13.6) with gastric cancer-related GI bleeding undergoing angiography between January 2000 and December 2015. Clinical course, laboratory findings, and TAE characteristics were reviewed. Technical success of TAE was defined as target area devascularization, and clinical success was defined as bleeding cessation with hemodynamic stability during 72 hours after TAE. Student t test was used for comparison of continuous variables, and Fisher exact test was used for categorical variables. Univariate and multivariate analysis were performed to identify predictors of successful TAE and 30-day survival after TAE. TAE was performed in 40 patients. Technical and clinical success rates of TAE were 85.0% and 65.0%, respectively. Splenic infarction occurred in 2 patients as a minor complication. Rebleeding after TAE occurred in 7 patients. Death related to bleeding occurred in 5 patients. Active bleeding (P = .044) and higher transfusion requirement (3.3 U ± 2.6 vs 1.8 U ± 1.7; P = .039) were associated with TAE failure. Successful TAE predicted improved 30-day survival after TAE on univariate and multivariate analysis (P = .018 and P = .022; odds ratio, 0.132). TAE for gastric cancer-associated GI bleeding may be a lifesaving procedure. Severe bleeding with a higher transfusion requirement and active bleeding on angiography predicted TAE failure. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
76 FR 72128 - Airworthiness Directives; Thielert Aircraft Engines GmbH (TAE) Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-22
... Service Information We reviewed TAE Service Bulletin (SB) No. TM TAE 125-1007 P1, Revision 3, dated...-E002801. Use paragraphs A. through B. of TAE Service Bulletin (SB) No. TM TAE 125-1007 P1, Revision 3, dated October 17, 2011, or SB No. TM TAE 125-1007 P1, Revision 2, dated April 29, 2009, to do the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-31
... Airworthiness Directives; Thielert Aircraft Engines GmbH Models TAE 125-02-99 and TAE 125-02-114 Reciprocating...). SUMMARY: We propose to adopt a new airworthiness directive (AD) for all TAE 125-02-99 and TAE 125-02-114... 125-02-99 engine. This proposed AD would require inspection of the oil filler plug vent hole at the...
Proceedings of the 5th Annual Users' Conference
NASA Technical Reports Server (NTRS)
Szczur, M. (Editor); Harris, E. (Editor)
1985-01-01
The Transportable Applications Executive (TAE) was conceived in 1979. It was proposed to be a general purpose software executive that could be applied in various systems. The success of this concept and of TAE was demonstrated. Topics included: TAE current status; TAE development; TAE applications; and UNIX emphasis.
76 FR 68636 - Airworthiness Directives; Thielert Aircraft Engines GmbH (TAE) Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-07
... Airworthiness Directives; Thielert Aircraft Engines GmbH (TAE) Reciprocating Engines AGENCY: Federal Aviation... airworthiness directive (AD) for Thielert Aircraft Engines GmbH (TAE) Models TAE 125-01 and TAE 125- 02-99 reciprocating engines. That AD currently requires replacement of certain part numbers (P/Ns) and serial numbers...
Ichiro, Ikushima; Shushi, Higashi; Akihiko, Ishii; Yasuhiko, Iryo; Yasuyuki, Yamashita
2011-07-01
To evaluate the efficacy and safety of empiric transcatheter arterial embolization (TAE) for patients with massive bleeding from duodenal ulcers. During January 2000 and December 2009, 59 patients with duodenal ulcer bleeding in whom TAE was attempted after endoscopic therapy failed were retrospectively analyzed. The patients were divided into empiric TAE (n = 36) and identifiable TAE (n = 23) groups according to angiographic findings with or without identification of the bleeding sites. The technical and clinical success rate, recurrent bleeding rate, procedure-related complications, and clinical outcomes were evaluated. The technical and clinical success rates of TAE were 100% and 83%. The recurrent bleeding rate, clinical success, duodenal stenosis, and 30-day mortality after TAE were not significantly different between the empiric and identifiable TAE groups. A high rate of technical and clinical success was obtained with empiric TAE comparable to identifiable TAE in patients with massive bleeding from duodenal ulcers. There were no severe complications. Empiric TAE is an effective and safe method when a bleeding site cannot determined by angiography. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Influence of ICRF heating on the stability of TAEs
NASA Astrophysics Data System (ADS)
Sears, J.; Burke, W.; Parker, R. R.; Snipes, J. A.; Wolfe, S.
2007-11-01
Unstable toroidicity-induced Alfv'en eigenmodes (TAEs) can appear spontaneously due to resonant interaction with fast particles such as fusion alphas, raising concern that TAEs may threaten ITER performance. This work investigates the progression of stable TAE damping rates toward instability during a scan of ICRF heating power up to 3.1 MW. Stable eigenmodes are identified in Alcator C-Mod by the Active MHD diagnostic. Unstable TAEs are observed to appear spontaneously in C-Mod limited L-mode plasmas at sufficient tail energies generated by >3 MW of ICRF heating. However preliminary analysis of experiments with moderate ICRF heating power show that TAE stability may not simply degrade with overall fast particle content. There are hints that the stability of some TAEs may be enhanced in the presence of fast particle distribution tails. Furthermore, the radial profile of the energetic particle distribution relative to the safety factor profile affects the ICRF power influence on TAE stability.
Mille, Markus; Huber, Juliane; Wlasak, Rüdiger; Engelhardt, Thomas; Hillner, Yvette; Kriechling, Henri; Aschenbach, Rene; Ende, Katrin; Scharf, Jens-Gerd; Puls, Ralf; Stier, Albrecht
2015-10-01
The aim of this study was to demonstrate the new strategy of prophylactic transcatheter arterial embolization (TAE) of the gastroduodenal artery after endoscopic hemostasis of bleeding duodenal ulcers. TAE is a well-established method for the treatment of recurrent or refractory ulcer bleeding resistant to endoscopic intervention, which increasingly replaces surgical procedures. A new approach for improving outcome and reducing rebleeding episodes is the supplemental and prophylactic TAE after successful endoscopic hemostasis. This retrospective study included all patients (n=117) treated from 2008 to 2012 for duodenal ulcer bleeding. After initial endoscopic hemostasis, patients were assessed regarding their individual rebleeding risk. Patients with a low rebleeding risk (n=47) were conservatively treated, patients with a high risk for rebleeding (n=55) had prophylactic TAE of the gastroduodenal artery, and patients with endoscopically refractory ulcer bleeding received immediate TAE. The technical success of prophylactic TAE was 98% and the clinical success was 87% of cases. Rebleeding occurred in 11% of patients with prophylactic TAE and was successfully treated with repeated TAE or endoscopy. The major complication rate was 4%. Surgery was necessary in only 1 prophylactic TAE patient (0.9%) during the whole study period. Mortality associated with ulcer bleeding was 4% in patients with prophylactic TAE. Prophylactic TAE in patients with duodenal ulcers at high risk for rebleeding was feasible, effective at preventing the need for surgery, and had low major complication rates. Given these promising outcomes, prophylactic TAE should be further evaluated as a preventative therapy in high-risk patients.
Lee, Shen-Yang; Hsu, Hsiang-Hao; Chen, Yung-Chang; Huang, Chen-Chih; Wong, Yon-Cheong; Wang, Li-Jen; Chuang, Cheng-Keng; Yang, Chih-Wei
2009-11-01
This study retrospectively evaluated outcomes, complications, and tumor shrinkage in renal angiomyolipomas after transcatheter arterial embolization (TAE). All renal angiomyolipoma patients who underwent TAE between August 2000 and December 2008 and had short-term (
Sixth Annual Users' Conference. [Transportable Applications Executive (TAE)
NASA Technical Reports Server (NTRS)
Szczur, Martha (Editor); Harris, Elfrieda (Editor)
1986-01-01
Conference papers and presentation outlines which address the use of the Transportable Applications Executive (TAE) and its various applications programs are compiled. Emphasis is given to the design of the user interface and image processing workstation in general. Alternate ports of TAE and TAE subsystems are also covered.
Clinical outcomes of symptomatic arterioportal fistulas after transcatheter arterial embolization
Hirakawa, Masakazu; Nishie, Akihiro; Asayama, Yoshiki; Ishigami, Kousei; Ushijima, Yasuhiro; Fujita, Nobuhiro; Honda, Hiroshi
2013-01-01
AIM: To evaluate the complications and clinical outcomes of transcatheter arterial embolization (TAE) for symptoms related to severe arterioportal fistulas (APFs). METHODS: Six patients (3 males, 3 females; mean age, 63.8 years; age range, 60-71 years) with chronic liver disease and severe APFs due to percutaneous intrahepatic treatment (n = 5) and portal vein (PV) tumor thrombosis of hepatocellular carcinoma (n = 1) underwent TAE for symptoms related to severe APFs [refractory ascites (n = 4), hemorrhoidal hemorrhage (n = 1), and hepatic encephalopathy (n = 1)]. Control of symptoms related to APFs and complications were evaluated during the follow-up period (range, 4-57 mo). RESULTS: In all patients, celiac angiography revealed immediate retrograde visualization of the main PV before TAE, indicating severe APF. Selective TAE for the hepatic arteries was performed using metallic coils (MC, n = 4) and both MCs and n-butyl cyanoacrylate (n = 2). Three patients underwent repeated TAEs for residual APFs and ascites. Four patients developed PV thrombosis after TAE. During the follow-up period after TAE, APF obliteration and symptomatic improvement were obtained in all patients. CONCLUSION: Although TAE for severe APFs may sometimes be complicated by PV thrombosis, TAE can be an effective treatment to improve clinical symptoms related to severe APFs. PMID:23494252
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-05
... Differences (f) None. Alternative Methods of Compliance (AMOCs) (g) The Manager, Engine Certification Office... Engines GmbH (TAE) Model TAE 125-01 Reciprocating Engines AGENCY: Federal Aviation Administration (FAA... 02-7250-18300R5, may cause a blow-by gas pressure increase inside the crankcase of the engine in...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-02
... Engines Installed In, But Not Limited To, Diamond Aircraft Industries Model DA 42 Airplanes; Correction..., Diamond Aircraft Industries model DA 42 airplanes. The part number for engine model TAE 125-01 is missing...-99 reciprocating engines, installed in, but not limited to, Diamond Aircraft Industries model DA 42...
Observation of odd toroidal Alfvén eigenmodes.
Kramer, G J; Sharapov, S E; Nazikian, R; Gorelenkov, N N; Budny, R V
2004-01-09
Experimental evidence is presented for the existence of the theoretically predicted odd toroidicity induced Alfvén eigenmode (TAE) from the simultaneous appearance of odd and even TAEs in a normal shear discharge of the joint European torus. The modes are observed in low central magnetic shear plasmas created by injecting lower hybrid current drive. A fast ion population was created by applying ion cyclotron heating at the high-field side to excite the TAEs. The odd TAEs were identified from their frequency, mode number, and timing relative to the even TAEs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shimohira, Masashi, E-mail: mshimohira@gmail.com; Hashizume, Takuya; Sasaki, Shigeru
PurposeTo assess the usefulness of transcatheter arterial embolization (TAE) for the hepatic arterial injury related to percutaneous transhepatic portal intervention (PTPI).Materials and MethodsFifty-four patients, 32 males and 22 females with a median age of 68 years (range 43–82 years), underwent PTPI. The procedures consisted of 33 percutaneous transhepatic portal vein embolizations, 19 percutaneous transhepatic variceal embolizations, and 2 percutaneous transhepatic portal venous stent placements. Two patients with gastric varices underwent percutaneous transhepatic variceal embolization twice because of recurrence. Therefore, the total number of procedures was 56. Among them, hepatic arterial injury occurred in 6 PTPIs in 5 patients, and TAE was performed.more » We assessed technical success, complications related to TAE, and clinical outcome. Technical success was defined as the disappearance of findings due to hepatic arterial injury on digital subtraction angiography.ResultsAs hepatic arterial injuries, 4 extravasations and 2 arterioportal shunts developed. All TAEs were performed successfully. The technical success rate was 100 %. Complication of TAE occurred in 5 of 6 TAEs; 3 were focal liver infarction, not requiring further treatment, and 2 were biloma that required percutaneous drainage. Five TAEs in 4 patients were performed immediately after the PTPI, and these 4 patients were alive. However, one TAE was performed 10 h later, and the patient died due to multiple organ failure 2 months later although TAE was successful.ConclusionTAE is a useful treatment for hepatic arterial injury related to PTPI. However, it should be performed at an early stage.« less
NASA Astrophysics Data System (ADS)
Sharapov, S. E.; Garcia-Munoz, M.; Van Zeeland, M. A.; Bobkov, B.; Classen, I. G. J.; Ferreira, J.; Figueiredo, A.; Fitzgerald, M.; Galdon-Quiroga, J.; Gallart, D.; Geiger, B.; Gonzalez-Martin, J.; Johnson, T.; Lauber, P.; Mantsinen, M.; Nabais, F.; Nikolaeva, V.; Rodriguez-Ramos, M.; Sanchis-Sanchez, L.; Schneider, P. A.; Snicker, A.; Vallejos, P.; the AUG Team; the EUROfusion MST1 Team
2018-01-01
Dedicated studies performed for toroidal Alfvén eigenmodes (TAEs) in ASDEX-Upgrade (AUG) discharges with monotonic q-profiles have shown that electron cyclotron resonance heating (ECRH) can make TAEs more unstable. In these AUG discharges, energetic ions driving TAEs were obtained by ion cyclotron resonance heating (ICRH). It was found that off-axis ECRH facilitated TAE instability, with TAEs appearing and disappearing on timescales of a few milliseconds when the ECRH power was switched on and off. On-axis ECRH had a much weaker effect on TAEs, and in AUG discharges performed with co- and counter-current electron cyclotron current drive (ECCD), the effects of ECCD were found to be similar to those of ECRH. Fast ion distributions produced by ICRH were computed with the PION and SELFO codes. A significant increase in T e caused by ECRH applied off-axis is found to increase the fast ion slowing-down time and fast ion pressure causing a significant increase in the TAE drive by ICRH-accelerated ions. TAE stability calculations show that the rise in T e causes also an increase in TAE radiative damping and thermal ion Landau damping, but to a lesser extent than the fast ion drive. As a result of the competition between larger drive and damping effects caused by ECRH, TAEs become more unstable. It is concluded, that although ECRH effects on AE stability in present-day experiments may be quite significant, they are determined by the changes in the plasma profiles and are not particularly ECRH specific.
Tan, Guosheng; Ma, Zhenjiang; Long, Weiqing; Liu, Liangshuai; Zhang, Bing; Chen, Wei; Yang, Jianyong; Li, Heping
2017-06-01
This study aimed to retrospectively evaluate the efficacy and safety of preoperative transcatheter arterial embolization (pTAE) for treating nasopharyngeal angiofibroma (NPAF). Seventy-four NPAF patients were hospitalized for elective surgical treatment with pTAE (pTAE group, n = 32) or surgical treatment alone (non-pTAE group, n = 42) between January 1990 and December 2013. The following outcome measures were retrospectively analyzed and compared: intraoperative bleeding volume, surgery time (ST), duration of postoperative hospital stay (PHS), and disease recurrence. Among Radkowski stage I patients, those in pTAE group had a slightly higher but not significant bleeding volume than patients in non-pTAE group (344 ± 407 vs. 248 ± 219 mL, P = 0.899); among stage II/III patients, however, patients in pTAE group showed a significantly lower bleeding volume than patients in non-pTAE group (stage II, 829 ± 519 vs. 1339 ± 767 mL, P = 0.035; stage III, 1267 ± 592 vs. 2125 ± 479 mL, P = 0.024). The two groups presented comparable OTs, PHSs, and rates of frontal recurrence (all P>0.05). pTAE significantly reduces intraoperative bleeding in NPAF patients with Radkowski stage II/III disease, but offers no additional benefits regarding ST, PHS, or recurrence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tan, Guosheng; Ma, Zhenjiang; Long, Weiqing
ObjectiveThis study aimed to retrospectively evaluate the efficacy and safety of preoperative transcatheter arterial embolization (pTAE) for treating nasopharyngeal angiofibroma (NPAF).MethodsSeventy-four NPAF patients were hospitalized for elective surgical treatment with pTAE (pTAE group, n = 32) or surgical treatment alone (non-pTAE group, n = 42) between January 1990 and December 2013. The following outcome measures were retrospectively analyzed and compared: intraoperative bleeding volume, surgery time (ST), duration of postoperative hospital stay (PHS), and disease recurrence.ResultsAmong Radkowski stage I patients, those in pTAE group had a slightly higher but not significant bleeding volume than patients in non-pTAE group (344 ± 407 vs. 248 ± 219 mL,more » P = 0.899); among stage II/III patients, however, patients in pTAE group showed a significantly lower bleeding volume than patients in non-pTAE group (stage II, 829 ± 519 vs. 1339 ± 767 mL, P = 0.035; stage III, 1267 ± 592 vs. 2125 ± 479 mL, P = 0.024). The two groups presented comparable OTs, PHSs, and rates of frontal recurrence (all P>0.05).ConclusionspTAE significantly reduces intraoperative bleeding in NPAF patients with Radkowski stage II/III disease, but offers no additional benefits regarding ST, PHS, or recurrence.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-28
... difference is to ensure that the compliance requirements for all engines in paragraph (e)(1) above are... Airworthiness Directives; Thielert Aircraft Engines GmbH Models TAE 125-02-99 and TAE 125-02-114 Reciprocating Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed rulemaking (NPRM...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-18
... amended the Airworthiness Limitation Section (ALS) of the Operation & Maintenance Manual OM-02-02 to... shutdowns of the engine(s). TAE has also amended the ALS of the Operation & Maintenance Manual OM- 02-01 to...-E000702 and has amended the Airworthiness Limitation Section (ALS) of the Operation & Maintenance Manual...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-23
... Airworthiness Directives; Thielert Aircraft Engines GmbH Models TAE 125-02-99 and TAE 125-02-114 Reciprocating Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: We are adopting a... condition, if not corrected, could lead to in-flight cases of engine shutdown. We are issuing this AD to...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-23
... showed that it was mainly the result of failure of the Proportional Pressure Reducing Valve (PPRV) (also... identified as the primary source of vibrations for the PPRV, and it has also been determined that failure of... TAE 125 engines. The investigations showed that it was mainly the result of failure of the PPRV due to...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soyer, Philippe, E-mail: philippe.soyer@lrb.aphp.fr; Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr; Dautry, Raphael, E-mail: raphael-dautry@yahoo.fr
Postpartum hemorrhage (PPH) is a potentially life-threatening condition, which needs multidisciplinary management. Uterine atony represents up to 80 % of all causes of PPH. Transcatheter arterial embolization (TAE) has now a well-established role in the management of severe PPH. TAE allows stopping the bleeding in 90 % of women with severe PHH, obviating surgery. Pledgets of gelatin sponge as torpedoes are commonly used for safe TAE, and coils, glue, and microspheres have been primarily used in specific situations such as arterial rupture, pseudoaneurysm, and arteriovenous fistula. TAE is a minimally invasive procedure with a low rate of complications, which preserves future fertility.more » Knowledge of causes of PPH, potential risks, and limitations of TAE is essential for a timely decision, optimizing TAE, preventing irreversible complications, avoiding hysterectomy, and ultimately preserving fertility.« less
Nonlinear Decay and Plasma Heating by a Toroidal Alfvén Eigenmode
NASA Astrophysics Data System (ADS)
Qiu, Z.; Chen, L.; Zonca, F.; Chen, W.
2018-03-01
We demonstrate theoretically that a toroidal Alfvén eigenmode (TAE) can parametrically decay into a geodesic acoustic mode and kinetic TAE in a toroidal plasma. The corresponding threshold condition for the TAE amplitude is estimated to be |δ B⊥/B0|˜O (10-4). Here, δ B⊥ and B0 are, respectively, the perturbed magnetic field of the pump TAE and the equilibrium magnetic field. This novel decay process, in addition to contributing to the nonlinear saturation of energetic-particle or α -particle driven TAE instability, could also contribute to the heating as well as regulating the transports of thermal plasmas.
Liguori, Giovanni; Amodeo, Antonio; Mucelli, Fabio Pozzi; Patel, Hiten; Marco, Doddi; Belgrano, Emanuele; Trombetta, Carlo
2010-08-01
To determine the feasibility and efficacy of transarterial embolization (TAE) in haemorrhagic urological emergencies, and to assess the perioperative morbidity, effect of timing of intervention on the requirement for blood transfusion, and the long-term follow-up. Between October 1997 and March 2009, 44 patients (30 men and 14 women; mean age 79 years, range 51-95) with intractable haematuria secondary to advanced pelvic tumour arising from or invading the bladder, underwent internal iliac TAE. Twenty-four patients had transitional carcinoma of the urinary bladder, 12 adenocarcinoma of the prostate, five carcinoma of the uterus, one cancer of the vagina, two carcinoma of the rectum, three carcinoma of the kidney, two simultaneous carcinoma of prostate and bladder, one simultaneous carcinoma of prostate and kidney and one had haemorrhagic cystitis after radiotherapy. TAE of the internal iliac arteries produced initial complete control of bleeding in 36 of the 44 patients (82%). At a mean (range) follow-up of 10.5 (1-97) months TAE there was permanent control of bleeding in 19 (43%) patients. A second TAE session was use in five (11%) patients and it was successful in two of them. There were 24 patients (55%) who required a mean of 4 (1-17) transfusion units before embolization; only 13 (30%) required more blood products after TAE. The mean haematocrit level before and after TAE was 27% and 31% (P < 0001), and the respective haemoglobin level were 8.7 and 10.3 g/dL (P < 0001). During the follow-up there were no major complications related to TAE; minor complications were post-TAE syndrome in 12 (27%) patients, fever (11%), gluteus pain (14%), nausea (2%), and exterior genital oedema (5%). The 6- and 12-month mortality rates were 66% (29 patients) and 18% (eight), respectively. TAE should be considered as an alternative less-invasive palliative measure and the treatment of choice in these situations. TAE should always be bilateral, the catheter should advance distally to the origin of the superior gluteal artery and the artery embolized with unresorbable particles. Our study confirms the efficacy and safety of TAE in patients with pelvic malignancy, and indicates that this technique should be considered before surgery. The procedure combines the benefits of a minimally invasive approach in decreasing the cost of surgery and operating time, while maintaining low blood loss and analgesia requirement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hao, Hui-fang; Takaoka, Munenori; Bao, Xiao-hong
2012-07-13
Highlights: Black-Right-Pointing-Pointer A novel FAK inhibitor TAE226 suppressed FAK activity in HCT116 colon cancer cells. Black-Right-Pointing-Pointer TAE226 suppressed proliferation and migration, with a modest effect on adhesion. Black-Right-Pointing-Pointer Silencing of FAK by siRNA made no obvious difference on cancer cell attachment. Black-Right-Pointing-Pointer TAE226 treatment suppressed the progression of peritoneal dissemination. Black-Right-Pointing-Pointer Oral administration of TAE226 prolonged the survival of tumor-bearing mice. -- Abstract: Peritoneal dissemination is one of the most terrible types of colorectal cancer progression. Focal adhesion kinase (FAK) plays a crucial role in the biological processes of cancer, such as cell attachment, migration, proliferation and survival, all ofmore » which are essential for the progression of peritoneal dissemination. Since we and other groups have reported that the inhibition of FAK activity exhibited a potent anticancer effect in several cancer models, we hypothesized that TAE226, a novel ATP-competitive tyrosine kinase inhibitor designed to target FAK, can prevent the occurrence and progression of peritoneal dissemination. In vitro, TAE226 greatly inhibited the proliferation and migration of HCT116 colon cancer cells, while their adhesion on the matrix surface was minimally inhibited when FAK activity and expression was suppressed by TAE226 and siRNA. In vivo, when HCT116 cells were intraperitoneally inoculated in mice, the cells could attach to the peritoneum and begin to grow within 24 h regardless of the pretreatment of cells with TAE226 or FAK-siRNA, suggesting that FAK is not essential, at least for the initial integrin-matrix contact. Interestingly, the treatment of mice before and after inoculation significantly suppressed cell attachment to the peritoneum. Furthermore, oral administration of TAE226 greatly reduced the size of disseminated tumors and prolonged survival in tumor-bearing mice. Taken together, a possible strategy for inhibiting peritoneal dissemination by targeting FAK with TAE226 appears to be applicable through anti-proliferative and anti-invasion/anti-migration mechanisms.« less
DARPA Initiative in Concurrent Engineering (DICE). Phase 2
1990-07-31
XS spreadsheet tool " Q-Calc spreadsheet tool " TAE+ outer wrapper for XS • Framemaker-based formal EDN (Electronic Design Notebook) " Data...shared global object space and object persistence. Technical Results Module Development XS Integration Environment A prototype of the wrapper concepts...for a spreadsheet integration environment, using an X-Windows based extensible Lotus 1-2-3 emulation called XS , and was (initially) targeted for
Zheng, Lin; Shin, Ji Hoon; Han, Kichang; Tsauo, Jiaywei; Yoon, Hyun-Ki; Ko, Gi-Young; Shin, Jong-Soo; Sung, Kyu-Bo
2016-11-01
To evaluate the effectiveness of transcatheter arterial embolization (TAE) for gastrointestinal (GI) bleeding caused by GI lymphoma. The medical records of 11 patients who underwent TAE for GI bleeding caused by GI lymphoma between 2001 and 2015 were reviewed retrospectively. A total of 20 TAE procedures were performed. On angiography, contrast extravasation, and both contrast extravasation and tumor staining were seen in 95 % (19/20) and 5 % (1/20) of the procedures, respectively. The most frequently embolized arteries were jejunal (n = 13) and ileal (n = 5) branches. Technical and clinical success rates were 100 % (20/20) and 27 % (3/11), respectively. The causes of clinical failure in eight patients were rebleeding at new sites. In four patients who underwent repeat angiography, the bleeding focus was new each time. Three patients underwent small bowel resection due to rebleeding after one (n = 2) or four (n = 1) times of TAEs. Another two patients underwent small bowel resection due to small bowel ischemia/perforation after three or four times of TAEs. The 30-day mortality rate was 18 % due to hypovolemic shock (n = 1) and multiorgan failure (n = 1). Angiogram with TAE shows limited therapeutic efficacy to manage GI lymphoma-related bleeding due to high rebleeding at new sites. Although TAE can be an initial hemostatic measure, surgery should be considered for rebleeding due to possible bowel ischemic complication after repeated TAE procedures.
Ti-rich komatiites from northern Norway
NASA Astrophysics Data System (ADS)
Barnes, Sarah-Jane; Often, Morten
1990-06-01
Komatiites of the Karasjok Greenstone Belt, northern Norway, show two unusual features: they have certain compositional differences compared with other komatiites, and they are largely volcaniclastic in origin. Their geological setting suggests that the komatiites were crupted into shallow water, thus permitting phreatomagmatic eruption, in a small ocean basin that opened in the Baltic Shield. The major oxides (except for TiO2), the trace elements Y, Sc, V, heavy rare earth elements (HREE), Cr, Co, Ni and the platinum group elements (PGE) cover similar ranges to those observed in other komatiites, but TiO2, Sm, Zr and Hf (Ti-associated elements, TAE) are enriched compared with abundances commonly reported for komatiites. Thus, the Karasjok komatiites have interelement ratios 2 to 3 times greater than chondritic between the TAE and the HREE, PGE, Sc, V, Y, Al (HRE-associated elements, HAE). The light rare earth elements (LREE), Ta and Th are enriched in some samples relative to Ti, Sm, Zr, and Hf, but are depleted in others. One group of rocks that is similar to the Karasjok komatiites both in terms of geological setting and geochemistry is the Baffin Bay picrites. The reason for the high concentrations of TAE in the Karasjok komatiites could be that they formed at lower degrees of partial melting than most komatiites. The greater-than-chondritic TAE/HAE ratios indicate that garnet was a residual phase during their formation, requiring that the melt formed at a pressure greater than 40 kb. A model involving decompression melting of a mantle plume rising in a rifting environment, can explain the main features of the Karasjok komatiites.
78 FR 1728 - Airworthiness Directives; Thielert Aircraft Engines GmbH Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-09
... scheduled maintenance, whichever occurs first, do the following. (1) Remove the oil filler plug and check... Airworthiness Directives; Thielert Aircraft Engines GmbH Reciprocating Engines AGENCY: Federal Aviation... all Thielert Aircraft Engines GmbH (TAE) TAE 125-02-99 and TAE 125-02-114 reciprocating engines. This...
78 FR 1733 - Airworthiness Directives; Thielert Aircraft Engines GmbH Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-09
... Airworthiness Directives; Thielert Aircraft Engines GmbH Reciprocating Engines AGENCY: Federal Aviation... (AD) for all Thielert Aircraft Engines GmbH models TAE 125-01, TAE 125-02- 99, and TAE 125-02-114 reciprocating engines. That AD currently requires installation of full-authority digital electronic control...
NASA Astrophysics Data System (ADS)
Pei, Youbin; Xiang, Nong; Shen, Wei; Hu, Youjun; Todo, Y.; Zhou, Deng; Huang, Juan
2018-05-01
Kinetic-MagnetoHydroDynamic (MHD) hybrid simulations are carried out to study fast ion driven toroidal Alfvén eigenmodes (TAEs) on the Experimental Advanced Superconducting Tokamak (EAST). The first part of this article presents the linear benchmark between two kinetic-MHD codes, namely MEGA and M3D-K, based on a realistic EAST equilibrium. Parameter scans show that the frequency and the growth rate of the TAE given by the two codes agree with each other. The second part of this article discusses the resonance interaction between the TAE and fast ions simulated by the MEGA code. The results show that the TAE exchanges energy with the co-current passing particles with the parallel velocity |v∥ | ≈VA 0/3 or |v∥ | ≈VA 0/5 , where VA 0 is the Alfvén speed on the magnetic axis. The TAE destabilized by the counter-current passing ions is also analyzed and found to have a much smaller growth rate than the co-current ions driven TAE. One of the reasons for this is found to be that the overlapping region of the TAE spatial location and the counter-current ion orbits is narrow, and thus the wave-particle energy exchange is not efficient.
Gao, Hui; Zhao, Mai-liang; Zhou, Ai-min; Zhang, Sheng; Song, Zhong-hai; Guo, Wen-ping; Deng, Zhi-an
2015-12-01
To observe the effect of transcutaneous acupoint electrical stimulation (TAES) of Zusanli (ST 36) on gastrointestinal activities in organophosphorus pesticide poisoning (OPP) patients undergoing emergency treatment so as to explore its action in scavenging gastrointestinal toxicant. A total of 116 OPP patients were randomly divided into control group and TAES group (n=58 in each group) according to the simple random sampling method. All the patients received comprehensive treatment including gastric lavage, catharsis, oral administration of atropine Pralidoxime Chloride, Omeprazole, etc. For patients of the TAES group, TAES stimulation (30 Hz/60 Hz, 15-20 mA) was applied to bilateral Zusanli (ST 36) for 30 min, 3 times a day till black stool was discharged. The vomiting times after catharsis, the time of the first defecation and black stool discharge, the dosage of atropine and the length of patient stay in hospital were recorded. Of the two 58 cases of OPP patients in the control and TAES groups, 11 (18.9%) and 3 (5.2%) underwent vomiting after catharsis, being significantly lower in the TAES group (P<0.05). Compared with the control group, the time of first defecation and black stool discharge, the dosage of the administrated atropine and the time of hospitalization were significantly lower in the TAES group (P<0.05). TAES of ST 36 may lower incidence of emesis, enhance the cathartic effect, promote gastrointestinal poison discharge, reduce total atropine dosage and shorten the hospitalization time in OPP patients, favoring the patient's rehabilitation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr; Eveno, Clarisse, E-mail: clarisse.eveno@lrb.aphp.fr; Dautry, Raphael, E-mail: raphael.dautry@lrb.aphp.fr
PurposeTo assess the role and effectiveness of percutaneous arterial embolization (TAE) in patients with hemodynamic instability due to hypovolemic shock secondary to ruptured splanchnic artery pseudoaneurysms (SAPA).Materials and MethodsSeventeen patients (11 men, 6 women; mean age, 53 years) with hemodynamic instability (systolic blood pressure <90 mmHg) due to hypovolemic shock secondary to ruptured SAPA were treated by TAE. Clinical files, multidetector row computed tomography angiography, and angiographic examinations along with procedure details were reviewed.ResultsSeventeen SAPAs were present, predominantly located on gastroduodenal or pancreatic arteries (9/17; 53 %). Angiography showed extravasation of contrast medium from SAPA in 15/17 patients (88 %). Technical success rate ofmore » TAE was 100 %. TAE was performed using metallic coils in all patients (100 %), in association with gelatin sponge in 5/17 patients (29 %). TAE allowed controlling the bleeding and returning to normal hemodynamic status in 16/17 patients (94 %). In 1/17 patient (6 %), surgery was needed to definitively control the bleeding. The mortality and morbidity rate of TAE at 30 days were 0 and 12 %, respectively. Morbidity consisted in coil migration in 1/17 patient (6 %) and transient serum liver enzyme elevation in 1/17 patient (6 %).ConclusionTAE is an effective and safe treatment option for ruptured SAPA in hemodynamically unstable patients, with a success rate of 94 %. Our results suggest that TAE should be the favored option in patients with hemodynamic instability due to ruptured SAPA.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Lin; Shin, Ji Hoon, E-mail: jhshin@amc.seoul.kr; Han, Kichang
PurposeTo evaluate the effectiveness of transcatheter arterial embolization (TAE) for gastrointestinal (GI) bleeding caused by GI lymphoma.Materials and MethodsThe medical records of 11 patients who underwent TAE for GI bleeding caused by GI lymphoma between 2001 and 2015 were reviewed retrospectively.ResultsA total of 20 TAE procedures were performed. On angiography, contrast extravasation, and both contrast extravasation and tumor staining were seen in 95 % (19/20) and 5 % (1/20) of the procedures, respectively. The most frequently embolized arteries were jejunal (n = 13) and ileal (n = 5) branches. Technical and clinical success rates were 100 % (20/20) and 27 % (3/11), respectively. The causes of clinical failuremore » in eight patients were rebleeding at new sites. In four patients who underwent repeat angiography, the bleeding focus was new each time. Three patients underwent small bowel resection due to rebleeding after one (n = 2) or four (n = 1) times of TAEs. Another two patients underwent small bowel resection due to small bowel ischemia/perforation after three or four times of TAEs. The 30-day mortality rate was 18 % due to hypovolemic shock (n = 1) and multiorgan failure (n = 1).ConclusionAngiogram with TAE shows limited therapeutic efficacy to manage GI lymphoma-related bleeding due to high rebleeding at new sites. Although TAE can be an initial hemostatic measure, surgery should be considered for rebleeding due to possible bowel ischemic complication after repeated TAE procedures.« less
Zhao, C; Pei, S-L; Cucchetti, A; Tong, T-J; Ma, Y-L; Zhong, J-H; Li, L-Q
2017-03-20
Transarterial embolisation (TAE) is a standard treatment for bleeding hepatocellular adenoma (HCA) and, occasionally, symptomatic HCA involving large tumours. Whether TAE is similarly safe and effective as an elective treatment for bleeding and nonbleeding HCA remains unclear. To investigate the benefits and harms of TAE for bleeding and nonbleeding HCA. PubMed, Scopus, Embase and Cochrane Library databases were systematically searched for studies that examined post-TAE tumour reduction in patients with bleeding or nonbleeding HCA and that were published between January 2000 and January 2017. Systematic review of 21 case series involving 1468 patients with HCA in the systematic review identified 140 (9.5%) patients with 189 lesions who received TAE. Of these 140 patients, 66.4% had bleeding HCA and 33.6% had nonbleeding HCA. Intended elective TAE was performed in 27.1% of patients (38.6% of HCA lesions). Adenomatosis was observed in 6.1% of patients, and the rate of β-catenin expression was 4.5%. No malignant transformation was observed among the 189 tumours during a median follow-up time of 40 months. The complete response rate among 70 patients was 10.6%, and the partial response rate was 71.7%. No mortality or severe adverse side effects were reported during the hospitalisation period. The available evidence suggests that TAE can be considered safe for elective managment of HCA as well as for management of bleeding HCA. Elective TAE can be regarded as a reasonable alternative to surgery. High-quality prospective studies with long-term follow-up are needed to corroborate and strengthen available evidence. © 2017 John Wiley & Sons Ltd.
76 FR 82110 - Airworthiness Directives; Thielert Aircraft Engines GmbH Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-30
... Airworthiness Directives; Thielert Aircraft Engines GmbH Reciprocating Engines AGENCY: Federal Aviation...) for Thielert Aircraft Engines GmbH models TAE 125-02-99 and TAE 125-01 reciprocating engines. That AD... flight hours to within 600 flight hours for TAE 125-01 reciprocating engines. This AD was prompted by the...
Primer for the Transportable Applications Executive
NASA Technical Reports Server (NTRS)
Carlson, P. A.; Emmanuelli, C. A.; Harris, E. L.; Perkins, D. C.
1984-01-01
The Transportable Applications Executive (TAE), an interactive multipurpose executive that provides commonly required functions for scientific analysis systems, is discussed. The concept of an executive is discussed and the various components of TAE are presented. These include on-line help information, the use of menus or commands to access analysis programs, and TAE command procedures.
Yeh, Mei-Ling; Chung, Yu-Chu; Hsu, Lun-Chia; Hung, Shuo-Hui
2018-05-01
Hemorrhoidectomy is the current best treatment for severe hemorrhoids, but it causes significant postoperative pain and anxiety, which is associated with heart rate variability (HRV). Transcutaneous acupoint electrical stimulation (TAES) was assumed to alleviate pain and anxiety, and modify the autonomic nervous system. This study aimed to examine the effects of TAES intervention on postoperative pain, anxiety, and HRV in patients who received a hemorrhoidectomy. A randomized-controlled trial with five repeated measures was conducted. The TAES group ( n = 39) received four 20-min sessions of electrical stimulation at chengshan (BL57) and erbai (EX-UE2) after hemorrhoidectomy, whereas the control group ( n = 41) did not. Data were collected using Visual Analogue Scale (VAS), State Anxiety Inventory (STAI), and HRV physiological signal monitor. TAES resulted in a significant group difference in pain scores, anxiety levels, and some HRV parameters. The findings indicate that TAES can help reduce pain and anxiety associated with hemorrhoidectomy. TAES is a noninvasive, simple, and convenient modality for post-hemorrhoidectomy-associated pain control and anxiety reduction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilkins, Luke R., E-mail: lrw6n@virginia.edu; Brautigan, David L., E-mail: db8g@virginia.edu; Wu, Hanping, E-mail: hanpingwumd@gmail.com
IntroductionWe hypothesize that the combination of transarterial embolization (TAE) plus inhibition of lactate export will limit anaerobic metabolism and reduce tumor survival compared to TAE alone. The purpose of this study was to test this hypothesis in a rat model of hepatocellular carcinoma (HCC).MethodsRat N1-S1 hepatoma cells were assayed in vitro using the Seahorse XF analyzer to measure extracellular acidification (lactate excretion) comparing effects of the addition of caffeic acid (CA) or ferulic acid (FA) or UK-5099 with control. Monocarboxylate transporter Slc16a3 was knocked down by RNAi. N1S1 tumors were orthotopically implanted in rats and 4 groups evaluated: (1) Control,more » (2) TAE-only, (3) TAE plus CA, and (4) TAE plus FA. Tumor size was determined by ultrasound and analyzed by repeated measures statistics. Tumors harvested at 4 weeks were examined by microscopy.ResultsSeahorse assays showed that CA and FA caused a significant reduction by >90% in lactate efflux by N1S1 tumor cells (p < 0.01). Knockdown of Slc16a3 prevented inhibition by CA. In vivo tumors grew 30-fold in volume over 4 weeks in untreated controls. By comparison, TAE resulted in near cessation of growth (10% in 4-week time period). However, both TAE + CA and TAE + FA caused a significant reduction of tumor volumes (87 and 72%, respectively) compared to control and TAE (p < 0.05). Pathologic evaluation revealed residual tumor in the TAE group but no residual viable tumor cells in the TAE + CA and TAE + FA groups.ConclusionAddition of CA or FA enhances the effectiveness of TAE therapy for HCC in part by blocking lactate efflux.« less
Koo, Hyun Jung; Shin, Ji Hoon; Shin, Sooyoung; Yoon, Hyun-Ki; Ko, Gi-Young; Gwon, Dong Il
2015-09-01
To evaluate the efficacy and clinical outcomes of transcatheter arterial embolization (TAE) for gastrointestinal (GI) bleeding from gastrointestinal stromal tumor (GIST). TAE was performed in 20 referred patients (male:female = 13:7; median age, 56.3 y) for GI bleeding from GISTs. The locations of GISTs were assessed using contrast-enhanced computed tomography (CT) and catheter angiography. The technical and clinical success of TAE and clinical outcomes including procedure-related complications, recurrent bleeding, 30-day and overall mortality, and cumulative survival were evaluated. The sites of GIST-related bleeding or tumor staining were the jejunum (n = 9), stomach (n = 5), ileum (n = 3), duodenum (n = 2), and jejunum and colon (n = 1). Angiography showed bleeding from GIST in 5 patients, and tumor staining was noted in only 15 patients. TAE was performed for patients with and without contrast medium extravasation on angiography. Technical and clinical success rates of TAE were 95% (19 of 20 patients) and 90% (18 of 20 patients), respectively. Recurrent bleeding was noted in 1 patient. There were no procedure-related complications. In 15 patients, surgical resection of the tumors was performed after TAE. The 30-day and overall mortality rates were 10% (2 of 20 patients) and 30% (6 of 20 patients), respectively. TAE is a safe and effective method for controlling GI bleeding from the GIST. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-08
... shortly after receipt. List of Subjects in 14 CFR Part 39 Air transportation, Aircraft, Aviation safety... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration 14 CFR Part 39 [Docket No. FAA-2009... Facility, U.S. Department of Transportation, 1200 New Jersey Avenue, SE., West Building Ground Floor, Room...
Kuo, Ling-Wei; Yang, Shang-Ju; Fu, Chih-Yuan; Liao, Chien-Hung; Wang, Shang-Yu; Wu, Shih-Chi
2016-01-01
In the evaluation of haemorrhage in trauma patients with pelvic fractures, contrast extravasation (CE) on computed tomography (CT) scan often implies active arterial bleeding. However, the absence of CE on CT scan does not always exclude the need for transcatheter arterial embolisation (TAE) to achieve haemostasis. In the current study, we evaluated the factors associated with the need for TAE in patients without CE on CT scan. These factors may be evaluated as adjuncts to CT scanning in the management of patients with pelvic fractures. We retrospectively reviewed our trauma registry and medical records of patients with pelvic fractures. When CE was observed, indicating active haemorrhage, the patients underwent TAE to achieve haemostasis. In contrast, patients without CE were held for observation and treatment of their injuries, and if their condition deteriorated after a delayed interval, they were then also referred for TAE if no other focus of haemorrhage was found. Patients without CE on CT scan but with retroperitoneal haemorrhage requiring TAE were investigated. Their demographic characteristics, associated injuries, fracture patterns, and changes in systolic blood pressure were described and analysed. In total, 201 patients with pelvic fracture underwent CT scan examination; 47 (23.4%) had CE by CT scan, whereas the other 154 (76.6%) did not. Of the 154 patients who did not show CE by CT scan, 124 (80.5%) patients never underwent TAE; however, 30 (19.5%) of these patients did eventually undergo TAE. In comparing the patients who underwent TAE to those who did not undergo TAE among patients without CE on CT scan, the systolic blood pressure (SBP) on arrival (median: 100.0 mmHg vs 136.0 mmHg, p<0.01) and the lowest SBP recorded in the ED (median: 68.0 mmHg vs 129.0 mmHg, p<0.01) were significantly lower in the patients who underwent TAE. The ROC curve analysis revealed that the most appropriate cutoff value of decrement of SBP (SBP on arrival minus the lowest SBP in the ED) was 30 mmHg (AUC=0.89). In the management of pelvic fracture patients, greater attention should be directed toward patients with relative hypotension. The higher likelihood of haemodynamic deterioration and the need for TAE for haemorrhage control should remain under consideration in such cases, despite the absence of CE by CT scan. Copyright © 2015 Elsevier Ltd. All rights reserved.
NIMROD calculations of energetic particle driven toroidal Alfvén eigenmodes
NASA Astrophysics Data System (ADS)
Hou, Yawei; Zhu, Ping; Kim, Charlson C.; Hu, Zhaoqing; Zou, Zhihui; Wang, Zhengxiong; Nimrod Team
2018-01-01
Toroidal Alfvén eigenmodes (TAEs) are gap modes induced by the toroidicity of tokamak plasmas in the absence of continuum damping. They can be excited by energetic particles (EPs) when the EP drive exceeds other dampings, such as electron and ion Landau damping, and collisional and radiative damping. A TAE benchmark case, which was proposed by the International Tokamak Physics Activity group, is studied in this work. The numerical calculations of linear growth of TAEs driven by EPs in a circular-shaped, large aspect ratio tokamak have been performed using the Hybrid Kinetic-MHD (HK-MHD) model implemented in the NIMROD code. This HK-MHD model couples a δf particle-in-cell representation of EPs with the 3D MHD representation of the bulk plasma through moment closure for the momentum conservation equation. Both the excitation of TAEs and their transition to energetic particle modes (EPMs) have been observed. The influence of EP density, temperature, density gradient, and position of the maximum relative density gradient, on the frequency and the growth rate of TAEs are obtained, which are consistent with those from the eigen-analysis calculations, kinetic-MHD, and gyrokinetic simulations for an initial Maxwellian distribution of EPs. The relative pressure gradient of EP at the radial location of the TAE gap, which represents the drive strength of EPs, can strongly affect the growth rate of TAEs. It is demonstrated that the mode transition due to EP drive variation leads to not only the change of frequency but also the change of the mode structure. This mechanism can be helpful in understanding the nonlinear physics of TAE/EPM, such as frequency chirping.
A Case of Traumatic Mesenteric Bleeding Controlled by only Transcatheter Arterial Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asayama, Yoshiki, E-mail: asayama@elf.coara.or.jp, E-mail: asayama@radiol.med.kyushu-u.ac.jp; Matsumoto, Shunichi; Isoda, Takuro
We report a case of mesenteric hematoma following blunt abdominal trauma that was successfully treated with transcatheter arterial embolization (TAE) and did not require surgical repair. A 43-year-old man with blunt abdominal trauma caused in a factory accident was admitted with a stable general condition and laboratory data. On CT examination, a large mesenteric hematoma with extravasation of contrast media was observed. TAE was first attempted to control the bleeding. A superior mesenteric angiogram showed extravasation of contrast medium from a branch of the ileocolic artery and obstruction of the cecal branch. After successful TAE using microcoils, the distal portionmore » of the cecal branch was still preserved via collateral circulation. No abdominal symptoms have occurred during the 7 months following TAE. In mesenteric injury cases with limited intestinal damage, TAE may therefore be a reasonable alternative to emergent laparotomy.« less
The evaluation and extension of TAE in the development of a user interface management system
NASA Technical Reports Server (NTRS)
Burkhart, Brenda; Sugar, Ross
1986-01-01
The development of a user interface management system (UIMS) for an information gathering and display system is discussed. The system interface requirements are outlined along with the UIMS functional characteristics. Those systems requirements which are supported by the current Transportable Applications Executive (TAE) are listed and necessary modifications to the TAE are described.
Nonlinear dynamics of toroidal Alfvén eigenmodes in the presence of tearing modes
NASA Astrophysics Data System (ADS)
Zhu, J.; Ma, Z. W.; Wang, S.; Zhang, W.
2018-04-01
A hybrid simulation is carried out to study nonlinear dynamics of n = 1 toroidal Alfvén eigenmodes (TAEs) with the m/n = 2/1 tearing mode. It is found that the n = 1 TAE is first excited by isotropic energetic particles at the linear stage and reaches the first steady state due to wave-particle interaction. After the saturation of the n = 1 TAE, the m/n = 2/1 tearing mode grows continuously and reaches its steady state due to nonlinear mode-mode coupling, especially, the n = 0 component plays a very important role in the tearing mode saturation. The results suggest that the enhancement of the tearing mode activity with increase of the resistivity could weaken the TAE frequency chirping through the interaction between the p = 1 TAE resonance and the p = 2 tearing mode resonance for passing particles in the phase space, which is opposite to the classical physical picture of the TAE frequency chirping that is enhanced with dissipation increase.
Tilt aftereffect following adaptation to translational Glass patterns
Pavan, Andrea; Hocketstaller, Johanna; Contillo, Adriano; Greenlee, Mark W.
2016-01-01
Glass patterns (GPs) consist of randomly distributed dot pairs (dipoles) whose orientations are determined by specific geometric transforms. We assessed whether adaptation to stationary oriented translational GPs suppresses the activity of orientation selective detectors producing a tilt aftereffect (TAE). The results showed that adaptation to GPs produces a TAE similar to that reported in previous studies, though reduced in amplitude. This suggests the involvement of orientation selective mechanisms. We also measured the interocular transfer (IOT) of the GP-induced TAE and found an almost complete IOT, indicating the involvement of orientation selective and binocularly driven units. In additional experiments, we assessed the role of attention in TAE from GPs. The results showed that distraction during adaptation similarly modulates the TAE after adapting to both GPs and gratings. Moreover, in the case of GPs, distraction is likely to interfere with the adaptation process rather than with the spatial summation of local dipoles. We conclude that TAE from GPs possibly relies on visual processing levels in which the global orientation of GPs has been encoded by neurons that are mostly binocularly driven, orientation selective and whose adaptation-related neural activity is strongly modulated by attention. PMID:27005949
Ronald, James; Nixon, Andrew B; Marin, Daniele; Gupta, Rajan T; Janas, Gemini; Chen, Willa; Suhocki, Paul V; Pabon-Ramos, Waleska; Sopko, David R; Starr, Mark D; Brady, John C; Hurwitz, Herbert I; Kim, Charles Y
2017-10-01
Purpose To identify changes in a broad panel of circulating angiogenesis factors after bland transcatheter arterial embolization (TAE), a purely ischemic treatment for hepatocellular carcinoma (HCC). Materials and Methods This prospective HIPAA-compliant study was approved by the institutional review board. Informed written consent was obtained from all participants prior to entry into the study. Twenty-five patients (21 men; mean age, 61 years; range, 30-81 years) with Liver Imaging Reporting and Data System category 5 or biopsy-proven HCC and who were undergoing TAE were enrolled from October 15, 2014, through December 2, 2015. Nineteen plasma angiogenesis factors (angiopoietin 2; hepatocyte growth factor; platelet-derived growth factor AA and BB; placental growth factor; vascular endothelial growth factor A and D; vascular endothelial growth factor receptor 1, 2, and 3; osteopontin; transforming growth factor β1 and β2; thrombospondin 2; intercellular adhesion molecule 1; interleukin 6 [IL-6]; stromal cell-derived factor 1; tissue inhibitor of metalloproteinases 1; and vascular cell adhesion molecule 1 [VCAM-1]) were measured by using enzyme-linked immunosorbent assays at 1 day, 2 weeks, and 5 weeks after TAE and were compared with baseline levels by using paired Wilcoxon tests. Tumor response was assessed according to modified Response Evaluation Criteria in Solid Tumors (mRECIST). Angiogenesis factor levels were compared between responders and nonresponders by mRECIST criteria by using unpaired Wilcoxon tests. Results All procedures were technically successful with no complications. Fourteen angiogenesis factors showed statistically significant changes following TAE, but most changes were transient. IL-6 was upregulated only 1 day after the procedure, but showed the largest increases of any factor. Osteopontin and VCAM-1 demonstrated sustained upregulation at all time points following TAE. At 3-month follow-up imaging, 11 patients had responses to TAE (complete response, n = 6; partial response, n = 5) and 11 patients were nonresponders (stable disease, n = 9; progressive disease, n = 2). In nonresponders, the percent change in IL-6 on the day after TAE (P = .033) and the mean percent change in osteopontin after TAE (P = .024) were significantly greater compared with those of responders. Conclusion Multiple angiogenesis factors demonstrated significant upregulation after TAE. VCAM-1 and osteopontin demonstrated sustained upregulation, whereas the rest were transient. IL-6 and osteopontin correlated significantly with radiologic response after TAE. © RSNA, 2017.
Zhang, Jin-Long; Yuan, Kai; Wang, Mao-Qiang; Yan, Jie-Yu; Xin, Hai-Nan; Wang, Yan; Liu, Feng-Yong; Bai, Yan-Hua; Wang, Zhi-Jun; Duan, Feng; Fu, Jin-Xin
2017-01-01
Background: Currently, treatment of symptomatic polycystic liver disease (PLD) is still a challenging problem, especially for these patients who are not feasible for surgery. Minimally invasive options such as laparoscopic fenestration and percutaneous cyst aspiration with sclerotherapy demonstrated disappointing results due to multiple lesions. Because the cysts in PLD are mostly supplied from hepatic arteries but not from portal veins, transcatheter arterial embolization (TAE) of the hepatic artery branches that supply the major hepatic cysts can lead to shrinkage of the cyst and liver size, relieve symptoms, and improve nutritional status. This study aimed to evaluate the effectiveness of TAE with a mixture of N-butyl-2-cyanoacrylate (NBCA) and iodized oil for patients with severe symptomatic PLD during a more than 2-year follow-up. Methods: Institutional review board had approved this study. Written informed consent was obtained from all patients. From February 2007 to December 2014, twenty-three patients (20 women and 3 men; mean age, 49.0 ± 14.5 years) infeasible for surgical treatments underwent TAE. Changes in the abdominal circumferences, volumes of intrahepatic cysts, hepatic parenchyma volume, and whole liver, clinical symptoms, laboratory data, and complications were evaluated after TAE. Results: Technical success was achieved in all cases. No procedure-related major complications occurred. The median follow-up period after TAE was 48.5 months (interquartile range, 30.0–72.0 months). PLD-related severe symptoms were improved remarkably in 86% of the treated patients; TAE failed to benefit in four patients (four patients did not benefit from TAE). The mean maximum abdominal circumference decreased significantly from 106.0 ± 8.0 cm to 87.0 ± 15.0 cm (P = 0.021). The mean intrahepatic cystic volume reduction rates compared with pre-TAE were 36% at 12 months, 37% at 24 months, and 38% at 36 months after TAE (P < 0.05). The mean liver volume reduction rates were 32% at 12 months, 31% at 24 months, and 33% at 36 months (P < 0.05). Conclusions: TAE with the mixture of NBCA and iodized oil appears to be a safe and effective treatment method for patients with symptomatic PLD, especially for those who are not good candidates for surgical treatments, to improve both hepatic volume and hepatic cysts volume. PMID:28776546
Wychowski, Thomas; Wang, Hongyue; Buniak, Liana; Henry, J Craig; Mohile, Nimish
2013-11-01
To identify risk factors for the development of tumor-associated epilepsy (TAE) and potential benefit of newer generation AEDs in seizure prevention. We performed an IRB approved retrospective study of newly diagnosed GBM patients at the University of Rochester between 1/1/05 and 5/13/11. Records were reviewed to describe demographics, seizure incidence, occurrence of status epilepticus, and AED use and toxicity. 172 patients with newly diagnosed GBM were included in the study. 53.4% developed TAE. 31.4% had seizure prior to diagnosis. 118 patients were seizure-free at diagnosis: 32.2% developed post-diagnosis TIE (PostTAE) and 60.2% remained seizure-free. 70 seizure-free patients received an AED peri-operatively. 36 were weaned off AEDs and 31 were continued. Incidence of PostTAE and time to first seizure were comparable in AED-treated and untreated patients. 4 PostTAE patients presented with status epilepticus (SE), all were not AED treated. AEDs were withdrawn in 10 patients due to toxicity: 9 from phenytoin and 1 from levetiracetam. There is a high incidence of PostTAE in GBM. Prophylactic AED therapy did not reduce PostTAE but may have prevented SE. Minimal toxicity was observed on 2nd generation AEDs. The high burden of epilepsy in this population and tolerability of newer AEDS suggest that AAN guidelines should be revisited. Copyright © 2013 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-16
... has amended the Airworthiness Limitation Section (ALS) of the Operation & Maintenance Manual OM-02-02... a new rail pressure control valve P/N 05-7320-E000702 and 02-7320-04100R3 and has amended the ALS of...-7320- 04100R3 and has amended the Airworthiness Limitation Section (ALS) of the Operation & Maintenance...
Refractory Gastrointestinal Bleeding: Role of Angiographic Intervention
2013-01-01
Although endoscopic hemostasis remains initial treatment modality for nonvariceal gastrointestinal (GI) bleeding, severe bleeding despite endoscopic management occurs in 5% to 10% of the patients, requiring surgery or transcatheter arterial embolization (TAE). TAE is now considered the first-line therapy for massive GI bleeding refractory to endoscopic management. GI endoscopists need to be familiar with indications, principles, outcomes, and complications of TAE, as well as embolic materials available. PMID:24143308
Jiang, Sen; Yu, Dong; Jie, Bing
2016-09-01
To evaluate transarterial embolization (TAE) for the management of anomalous systemic arterial (ASA) supply to normal basal segments of the lung. Thirteen patients with ASA supply to normal basal segments of the lung underwent TAE. All patients presented with hemoptysis and had complete-type anomalies on pre-TAE or post-TAE computed tomography (CT). The anomaly was unilateral in all patients; 11 lesions were located in the left lung and 2 in the right. All patients underwent embolization with coils (n = 10) or a vascular plug (n = 3). Procedural success, clinical efficacy, and complications were assessed. Mean post-TAE CT and clinical follow-up was 25.4 and 42.1 months, respectively. Technical success was achieved in 100 % of cases. Several changes were noted on follow-up CT: complete obstruction of the ASA in all cases, normal (n = 11) or decreased (n = 2) density of the affected lung parenchyma, reduction of the primary enlarged inferior pulmonary vein in all cases, and pulmonary infarction and thickening of the corresponding bronchial artery (n = 4). The main complication was pulmonary infarction in four cases. TAE is a safe, effective, and minimally invasive therapeutic option for patients with ASA supply to normal basal segments of the lung.
Alexander, Matthew D; Hippe, Daniel S; Cooke, Daniel L; Hallam, Danial K; Hetts, Steven W; Kim, Helen; Lawton, Michael T; Sekhar, Laligam N; Kim, Louis J; Ghodke, Basavaraj V
2018-03-01
High-risk components of brain arteriovenous malformations (BAVMs) can be targeted to reduce the risk of lesion rupture. To evaluate targeted embolization of aneurysms against other means of treatment with a case-control analysis; we previously investigated this approach associated with BAVMs. Retrospective analysis of patients with BAVMs was performed, identifying patients treated with intention to occlude only an aneurysm associated with a BAVM. For each targeted aneurysm embolization (TAE) patient identified, 4 control patients were randomly selected, controlling for rupture status, age, and Spetzler-Martin plus Lawton-Young supplemental score. Analysis was performed to compare rates of adverse events (hemorrhage, new seizure, and death) between the 2 groups. Thirty-two patients met inclusion criteria, and 128 control patients were identified, out of 1103 patients treated during the study period. Thirty-four adverse events occurred (15 ruptures, 15 new seizures, and 11 deaths) during the follow-up period (mean 1157 d for the TAE cohort and 1036 d for the non-TAE cohort). Statistically lower associations were noted for the TAE group for any adverse event (hazard ratio 0.28, P = .037) and the composite outcome of hemorrhage or new seizure (hazard ratio 0.20, P = .029). For BAVMs at high risk for surgical resection, TAE can be performed safely and effectively. Patients treated with TAE had better outcomes than matched patients undergoing other combinations of treatment. TAE can be considered for BAVMs with high operative risk prior to radiosurgery or when no other treatment options are available. Copyright © 2017 by the Congress of Neurological Surgeons
Zhao, Xiang Yu; Hong, Po; Chen, Xiang Bin; Ye, Xing Guo; Pan, Yan You; Wang, Jian
2016-01-01
Timing of flowering is not only an interesting topic in developmental biology, but it also plays a significant role in agriculture for its effects on the maturation time of seed. The hexaploid wheat (Triticum aestivum) is one of the most important crop species whose flowering time, i.e. heading time, greatly influences yield. However, it remains unclear whether and how microRNAs regulate heading time in it. In our current study, we identified the tae-miR408 in wheat and its targets in vivo, including Triticum aestivum TIMING OF CAB EXPRESSION-A1 (TaTOC-A1), TaTOC-B1, and TaTOC-D1. The tae-miR408 levels were reciprocal to those of TaTOC1s under long-day and short-day conditions. Wheat plants with a knockdown of TaTOC1s via RNA interference and overexpression of tae-miR408 showed early-heading phenotype. Furthermore, TaTOC1s expression was down-regulated by the tae-miR408 in the hexaploid wheat. In addition, other important agronomic traits in wheat, such as plant height and flag leaf angle, were regulated by both tae-miR408 and TaTOC1s. Thus, our results suggested that the tae-miR408 functions in the wheat heading time by mediating TaTOC1s expression, and the study provides important new information on the mechanism underlying heading time regulation in wheat. PMID:26768600
Zhao, Xiang Yu; Hong, Po; Wu, Ji Yun; Chen, Xiang Bin; Ye, Xing Guo; Pan, Yan You; Wang, Jian; Zhang, Xian Sheng
2016-03-01
Timing of flowering is not only an interesting topic in developmental biology, but it also plays a significant role in agriculture for its effects on the maturation time of seed. The hexaploid wheat (Triticum aestivum) is one of the most important crop species whose flowering time, i.e. heading time, greatly influences yield. However, it remains unclear whether and how microRNAs regulate heading time in it. In our current study, we identified the tae-miR408 in wheat and its targets in vivo, including Triticum aestivum TIMING OF CAB EXPRESSION-A1 (TaTOC-A1), TaTOC-B1, and TaTOC-D1. The tae-miR408 levels were reciprocal to those of TaTOC1s under long-day and short-day conditions. Wheat plants with a knockdown of TaTOC1s via RNA interference and overexpression of tae-miR408 showed early-heading phenotype. Furthermore, TaTOC1s expression was down-regulated by the tae-miR408 in the hexaploid wheat. In addition, other important agronomic traits in wheat, such as plant height and flag leaf angle, were regulated by both tae-miR408 and TaTOC1s. Thus, our results suggested that the tae-miR408 functions in the wheat heading time by mediating TaTOC1s expression, and the study provides important new information on the mechanism underlying heading time regulation in wheat. © 2016 American Society of Plant Biologists. All Rights Reserved.
Braren, Rickmer; Altomonte, Jennifer; Settles, Marcus; Neff, Frauke; Esposito, Irene; Ebert, Oliver; Schwaiger, Markus; Rummeny, Ernst; Steingoetter, Andreas
2011-11-01
The hepatocellular carcinoma (HCC) exhibits varying degrees of vascularization with more poorly differentiated carcinoma commonly exhibiting high amounts of vascularization. Transcatheter arterial embolization (TAE) of HCC tumor nodules results in varying amounts of tumor necrosis. Reliable quantification of necrosis after TAE, would aid in treatment planning and testing of novel combinatorial treatment regimen. The aim of this work was to validate different imaging parameters as individual or combined predictors of tumor necrosis after TAE in an orthotopic rat HCC tumor model. Unifocal rat HCC was imaged by T(2)-weighted MRI, quantitative dynamic contrast enhanced (DCE) MRI, diffusion weighted MRI (DWI) and [(18)F]-FDG PET imaging before (day-1) and after (days 1 and 3) TAE. Univariate and multivariate regression analyses were carried out to analyze the ability of each imaging parameter to predict the percent residual vital tumor (vtu) and vital tissue (vti) as determined by quantitative histopathology. TAE induced a wide range of tumor necrosis. Tumor volume was the only parameter showing a correlation with vti (r(2) = 0.63) before TAE. After TAE, moderate correlations were found for FDG tracer uptake (r(2) = 0.56) and plasma tissue transfer constant (r(2) = 0.55). Correlations were higher for the extravascular extracellular volume fraction (v(e), r(2) = 0.68) and highest for the apparent diffusion coefficient (ADC, r(2) = 0.86). Multivariate analyses confirmed highest correlation of ADC and v(e) with vtu and vti. DWI and DCE-MRI with the respective parameters ADC (day 3) and v(e) (day 1) were identified as the most promising imaging techniques for the prediction of necrosis. This study validates a preclinical platform allowing for the improved tumor stratification after TAE and thus the testing of novel combinatorial therapy approaches in HCC. Copyright © 2011 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
High beta effects and nonlinear evolution of the TAE instability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spong, D.A.
1992-12-31
The toroidal Alfven eigenmode has recently been observed experimentally on DIII-D and TFTR when neutral beams are injected near the Alfven velocity. This instability is also of concern for future high {beta} D-T devices where fusion by-product alpha populations will generally be super-Alfvenic. We have developed a gyrofluid model (with Landau closure) of the TAE mode which can include most of the relevant damping mechanisms (continuum damping, ion and electron damping, ion FLR and collisional trapped electron damping) as well as reproducing analytically predicted undamped growth rates relatively accurately. An important consideration in predicting future unstable TAE regimes is themore » effect of finite beta in the background plasma. Due to the Shafranov shift and distortion of the flux surfaces, the location of the stable TAE root and the continuum will shift with increasing {beta}. The net effect of this is to generally enhance continuum damping and stabilize the TAF instability. Also, as the pressure gradient drive from the background becomes increasingly important, coupling between TAE and background driven modes can alter the TAE mode. A further application of our gyrofluid model which will be discussed is the nonlinear evolution of the TAE instability. Gyrofluid models offer a convenient reduced description which is more amenable to computational nonlinear modeling than full kinetic particle models. Our results demonstrate the rise and crash phases of TAE activity similar to experimental observations. The saturation is caused by generation of m=0 n=0 components through nonlinear beatings of the n > 1 modes; these cause modifications to the original equilibrium profiles in such a direction as to decrease the instability drive. This is the gyrofluid analog of direct particle losses. The peak magnetic fluctuation level increases with increasing energetic species beta, resulting in non-resonant stochastization of magnetic field lines.« less
High beta effects and nonlinear evolution of the TAE instability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spong, D.A.
1992-01-01
The toroidal Alfven eigenmode has recently been observed experimentally on DIII-D and TFTR when neutral beams are injected near the Alfven velocity. This instability is also of concern for future high [beta] D-T devices where fusion by-product alpha populations will generally be super-Alfvenic. We have developed a gyrofluid model (with Landau closure) of the TAE mode which can include most of the relevant damping mechanisms (continuum damping, ion and electron damping, ion FLR and collisional trapped electron damping) as well as reproducing analytically predicted undamped growth rates relatively accurately. An important consideration in predicting future unstable TAE regimes is themore » effect of finite beta in the background plasma. Due to the Shafranov shift and distortion of the flux surfaces, the location of the stable TAE root and the continuum will shift with increasing [beta]. The net effect of this is to generally enhance continuum damping and stabilize the TAF instability. Also, as the pressure gradient drive from the background becomes increasingly important, coupling between TAE and background driven modes can alter the TAE mode. A further application of our gyrofluid model which will be discussed is the nonlinear evolution of the TAE instability. Gyrofluid models offer a convenient reduced description which is more amenable to computational nonlinear modeling than full kinetic particle models. Our results demonstrate the rise and crash phases of TAE activity similar to experimental observations. The saturation is caused by generation of m=0 n=0 components through nonlinear beatings of the n > 1 modes; these cause modifications to the original equilibrium profiles in such a direction as to decrease the instability drive. This is the gyrofluid analog of direct particle losses. The peak magnetic fluctuation level increases with increasing energetic species beta, resulting in non-resonant stochastization of magnetic field lines.« less
1986-11-19
Currently, the Korean opposition party leader most publicized in the U.S. media is Kim Tae -chung. His exile in Washington brought him fame as an...opposition party leader. Kim Tae -chung has appeared on the popular ABC current events program "Nightline," and he is frequently featured in newspapers...opposition party politicians. Kim Tae -chung, last May, wrote an article for THE WASHINGTON POST entitled, "What We Want." Mr Kim in this article
Ubara, Yoshifumi; Mise, Koki; Ueno, Toshiharu; Sumida, Keiichi; Yamanouchi, Masayuki; Hayami, Noriko; Hoshino, Junichi; Kawada, Masahiro; Imafuku, Aya; Hiramatsu, Rikako; Hasegawa, Eiko; Sawa, Naoki; Takaichi, Kenmei
2016-01-01
In patients with autosomal dominant polycystic kidney disease (ADPKD), massive renal enlargement is a serious problem. Renal transcatheter arterial embolization (TAE) can reduce renal volume (RV), but effectiveness varies widely, and the reasons remain unclear. We investigated factors affecting renal volume reduction rate (RVRR) after renal TAE in all 449 patients with ADPKD who received renal TAE at Toranomon Hospital from January of 2006 to July of 2013, including 228 men and 221 women (mean age =57.0±9.1 years old). One year after renal TAE, the RVRR ranged from 3.9% to 84.8%, and the least squares mean RVRR calculated using a linear mixed model was 45.5% (95% confidence interval [95% CI], 44.2% to 46.8%). Multivariate analysis using the linear mixed model revealed that RVRR was affected by the presence of large cysts with wall thickening (regression coefficient [RC], −6.10; 95% CI, −9.04 to −3.16; P<0.001), age (RC, −0.82; 95% CI, −1.03 to −0.60; P<0.001), dialysis duration (RC, −0.10; 95% CI, −0.18 to −0.03; P<0.01), systolic BP (RC, 0.39; 95% CI, 0.19 to 0.59; P<0.001), and the number of microcoils used for renal TAE (RC, 1.35; 95% CI, 0.83 to 1.86; P<0.001). Significantly more microcoils were needed to achieve renal TAE in patients with younger age and shorter dialysis duration. In conclusion, cyst wall thickening had an important effect on cyst volume reduction. Renal TAE was more effective in patients who were younger, had shorter dialysis duration, or had hypertension, parameters that might associate with cyst wall stiffness and renal artery blood flow. PMID:26620095
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seki, Akihiko, E-mail: sekia@igtc.jp; Hori, Shinichi, E-mail: horishin@igtc.jp; Sueyoshi, Satoru, E-mail: sueyoshis@igtc.jp
2013-12-15
Purpose: This retrospective study aimed to evaluate the safety and local efficacy of transcatheter arterial embolization (TAE) with superabsorbent polymer microspheres (SAP-MS) in patients with pulmonary metastases from renal cell carcinoma (RCC). Methods: Sixteen patients with unresectable pulmonary metastases from RCC refractory to standard therapy were enrolled to undergo TAE with the purpose of mass reduction and/or palliation. The prepared SAP-MS swell to approximately two times larger than their dry-state size (100-150 {mu}m [n = 14], 50-100 {mu}m [n = 2]). Forty-nine pulmonary nodules (lung n = 22, mediastinal lymph node n = 17, and hilar lymph node n =more » 10) were selected as target lesions for evaluation. Local tumor response was evaluated 3 months after TAE according to Response Evaluation Criteria in Solid Tumors (RECIST; version 1.1). The relationship between tumor enhancement ratio by CT during selective angiography and local tumor response was evaluated. Results: The number of TAE sessions per patient ranged from 1 to 5 (median 2.9). Embolized arteries at initial TAE were bronchial arteries in 14 patients (87.5 %) and nonbronchial systemic arteries in 11 patients (68.8 %). Nodule-based evaluation showed that 5 (10.2 %) nodules had complete response, 17 (34.7 %) had partial response, 15 (30.6 %) had stable disease, and 12 (24.5 %) had progressive disease. The response rate was significantly greater in 22 lesions that had a high tumor enhancement ratio than in 27 lesions that had a slight or moderate ratio (90.9 vs. 7.4 %, p = 0.01). Severe TAE-related adverse events did not occur. Conclusion: TAE with SAP-MS might be a well-tolerated and locally efficacious palliative option for patients with pulmonary metastases from RCC.« less
Lee, Han Hee; Park, Jae Myung; Chun, Ho Jong; Oh, Jung Suk; Ahn, Hyo Jun; Choi, Myung-Gyu
2015-07-01
Transcatheter arterial embolization (TAE) is a therapeutic option for endoscopically unmanageable upper gastrointestinal (GI) bleeding. We aimed to assess the efficacy and clinical outcomes of TAE for acute non-variceal upper GI bleeding and to identify predictors of recurrent bleeding within 30 days. Visceral angiography was performed in 66 patients (42 men, 24 women; mean age, 60.3 ± 12.7 years) who experienced acute non-variceal upper GI bleeding that failed to be controlled by endoscopy during a 7-year period. Clinical information was reviewed retrospectively. Outcomes included technical success rates, complications, and 30-day rebleeding and mortality rates. TAE was feasible in 59 patients. The technical success rate was 98%. Rebleeding within 30 days was observed in 47% after an initial TAE and was managed with re-embolization in 8, by endoscopic intervention in 5, by surgery in 2, and by conservative care in 12 patients. The 30-day overall mortality rate was 42.4%. In the case of initial endoscopic hemostasis failure (n = 34), 31 patients underwent angiographic embolization, which was successful in 30 patients (96.8%). Rebleeding occurred in 15 patients (50%), mainly because of malignancy. Two factors were independent predictors of rebleeding within 30 days by multivariate analysis: coagulopathy (odds ratio [OR] = 4.37; 95% confidence interval [CI]: 1.25-15.29; p = 0.021) and embolization in ≥2 territories (OR = 4.93; 95% CI: 1.43-17.04; p = 0.012). Catheterization-related complications included hepatic artery dissection and splenic embolization. TAE controlled acute non-variceal upper GI bleeding effectively. TAE may be considered when endoscopic therapy is unavailable or unsuccessful. Correction of coagulopathy before TAE is recommended.
Suwabe, Tatsuya; Ubara, Yoshifumi; Mise, Koki; Ueno, Toshiharu; Sumida, Keiichi; Yamanouchi, Masayuki; Hayami, Noriko; Hoshino, Junichi; Kawada, Masahiro; Imafuku, Aya; Hiramatsu, Rikako; Hasegawa, Eiko; Sawa, Naoki; Takaichi, Kenmei
2016-07-01
In patients with autosomal dominant polycystic kidney disease (ADPKD), massive renal enlargement is a serious problem. Renal transcatheter arterial embolization (TAE) can reduce renal volume (RV), but effectiveness varies widely, and the reasons remain unclear. We investigated factors affecting renal volume reduction rate (RVRR) after renal TAE in all 449 patients with ADPKD who received renal TAE at Toranomon Hospital from January of 2006 to July of 2013, including 228 men and 221 women (mean age =57.0±9.1 years old). One year after renal TAE, the RVRR ranged from 3.9% to 84.8%, and the least squares mean RVRR calculated using a linear mixed model was 45.5% (95% confidence interval [95% CI], 44.2% to 46.8%). Multivariate analysis using the linear mixed model revealed that RVRR was affected by the presence of large cysts with wall thickening (regression coefficient [RC], -6.10; 95% CI, -9.04 to -3.16; P<0.001), age (RC, -0.82; 95% CI, -1.03 to -0.60; P<0.001), dialysis duration (RC, -0.10; 95% CI, -0.18 to -0.03; P<0.01), systolic BP (RC, 0.39; 95% CI, 0.19 to 0.59; P<0.001), and the number of microcoils used for renal TAE (RC, 1.35; 95% CI, 0.83 to 1.86; P<0.001). Significantly more microcoils were needed to achieve renal TAE in patients with younger age and shorter dialysis duration. In conclusion, cyst wall thickening had an important effect on cyst volume reduction. Renal TAE was more effective in patients who were younger, had shorter dialysis duration, or had hypertension, parameters that might associate with cyst wall stiffness and renal artery blood flow. Copyright © 2016 by the American Society of Nephrology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Sen, E-mail: jasfly77@vip.163.com; Yu, Dong; Jie, Bing
PurposeTo evaluate transarterial embolization (TAE) for the management of anomalous systemic arterial (ASA) supply to normal basal segments of the lung.MethodsThirteen patients with ASA supply to normal basal segments of the lung underwent TAE. All patients presented with hemoptysis and had complete-type anomalies on pre-TAE or post-TAE computed tomography (CT). The anomaly was unilateral in all patients; 11 lesions were located in the left lung and 2 in the right. All patients underwent embolization with coils (n = 10) or a vascular plug (n = 3). Procedural success, clinical efficacy, and complications were assessed. Mean post-TAE CT and clinical follow-up was 25.4 and 42.1 months,more » respectively.ResultsTechnical success was achieved in 100 % of cases. Several changes were noted on follow-up CT: complete obstruction of the ASA in all cases, normal (n = 11) or decreased (n = 2) density of the affected lung parenchyma, reduction of the primary enlarged inferior pulmonary vein in all cases, and pulmonary infarction and thickening of the corresponding bronchial artery (n = 4). The main complication was pulmonary infarction in four cases.ConclusionTAE is a safe, effective, and minimally invasive therapeutic option for patients with ASA supply to normal basal segments of the lung.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erdogan, Deha; Delden, Otto M. van; Busch, Olivier R. C.
2007-11-15
Hepatocellular adenomas (HCAs) are benign liver lesions which may be complicated by spontaneous intratumoral bleeding, with or without rupture into the abdominal cavity, or malignant degeneration. Recent advances in radiological interventional techniques now offer selective transcatheter arterial embolization (TAE) as an alternative approach to surgery as the initial treatment to stop the bleeding or as an elective treatment to reduce the tumor mass of the HCA. Herein, we report our initial experience using TAE in the management of HCA. Five female patients and one male patient presented with spontaneous hemorrhage of HCA. Four patients were initially treated with selective TAEmore » to stop the bleeding. In two patients in whom the bleeding stopped spontaneously, TAE was electively undertaken 1 year after presentation to reduce the tumor mass of HCAs >5 cm. Selective TAE as initial treatment in patients with spontaneous bleeding of HCA with or without rupture is effective and will change the need for urgent laparotomy to control bleeding. Selective TAE may also be used as an elective treatment to reduce the tumor mass of larger HCAs.« less
Imai, Yusuke; Hirooka, Masashi; Koizumi, Yohei; Nakamura, Yoshiko; Watanabe, Takao; Yoshida, Osamu; Tokumoto, Yoshio; Takeshita, Eiji; Abe, Masanori; Hiasa, Yoichi
2017-01-01
Hepatic aneurysms are rare, but can prove fatal once they rupture. Transcatheter arterial embolization (TAE) is performed as a prophylactic treatment. The position of the aneurysm determines the degree of difficulty of TAE. Maintaining blood flow to the liver can become difficult, particularly when the aneurysm is at an arterial junction. The patient was a 72-year-old man diagnosed with a hepatic aneurysm. The aneurysm was situated on the common hepatic artery at the junction of the gastroduodenal and proper hepatic arteries. TAE was performed with framing, followed by coil embolization. Blood flow to the liver was maintained via the gastroduodenal artery. Appropriate framing is important for safe and efficient TAE.
NASA Astrophysics Data System (ADS)
Yang, S. X.; Hao, G. Z.; Liu, Y. Q.; Wang, Z. X.; Hu, Y. J.; Zhu, J. X.; He, H. D.; Wang, A. K.
2018-04-01
The toroidal Alfvén eigenmode (TAE), excited by trapped energetic particles (EPs), is numerically investigated in a tokamak plasma, using the non-perturbative magnetohydrodynamic-kinetic hybrid formulation based MARS-K code (Liu et al 2008 Phys. Plasmas 15 112503). Compared with the fixed boundary condition at the plasma edge, a free boundary enhances the critical value of the EPs kinetic contribution for driving the TAE. Free boundary also induces finite perturbations at the plasma edge as expected. An anisotropic distribution of EPs, in the particle pitch angle space, strongly enhances the instability and results in a more global mode structure, compared with the isotropic case. The plasma resistivity is also found to play a role in the EPs-destabilized TAE. In particular, the mode stability domain is mapped out, in the 2D parameter space of the plasma resistivity and a quantity defining the width of the particle distribution in pitch angle (for anisotropic distribution). A resonance layer in the poloidal mode structure, with the layer width increasing with the plasma resistivity, appears at the large width of the particle distribution in pitch angle space. A mode conversion, from the modified ideal kink by the EPs kinetic effect to the TAE, is also observed while increasing the birth energy of EPs. Computational results suggest that the TAE mode structure can be modified by certain key plasma parameters, such as the EPs kinetic contribution, the equilibrium pressure, the plasma resistivity, the distribution of EPs, as well as the birth energy of EPs. Such modification of the eigenmode structure can only be obtained following the non-perturbative hybrid approach (Wang et al 2013 Phys. Rev. Lett. 111 145003, Wang et al 2015 Phys. Plasmas 22 022509), as adopted in this study. More importantly, numerical results show that near the marginal stability point, the dominant poloidal harmonics of the TAE overlap with each other, and are localized at the tip positions of the Alfvén continua. This kind of TAE structure in high beta plasma with unstable ideal kink is substantially different from that of the conventional TAE.
Suwabe, Tatsuya; Ubara, Yoshifumi; Sekine, Akinari; Ueno, Toshiharu; Yamanouchi, Masayuki; Hayami, Noriko; Hoshino, Junichi; Kawada, Masahiro; Hiramatsu, Rikako; Hasegawa, Eiko; Sawa, Naoki; Takaichi, Kenmei
2017-07-01
Currently, there are few strategies for improving the quality of life (QOL) in patients with autosomal dominant polycystic kidney disease (ADPKD) and massive kidneys. Renal transcatheter arterial embolization (TAE) reduces kidney volume, but its impact on QOL in ADPKD patients on hemodialysis is unknown. This study investigated the influence of renal TAE on QOL in ADPKD patients with massive kidneys receiving hemodialysis. This prospective observational study enrolled 188 ADPKD patients on hemodialysis (92 men and 96 women; mean age 56.7 ± 9.1 years) who underwent renal TAE at Toranomon Hospital between August 2010 and July 2014. The 36-item Short Form Health Survey (SF-36) and our original 15-item questionnaire were used to evaluate QOL. Using a linear mixed model, the least squares mean values of the SF-36 physical component summary (PCS), mental component summary (MCS) and role/social component summary (RCS) before renal TAE were calculated as 38.21 [95% confidence interval (CI) 36.50-39.91], 48.45 (47.05-49.86) and 43.04 (40.70-45.37), respectively. These values improved to 42.0 (40.22-43.77; P < 0.001 versus before TAE), 51.25 (49.78-52.71; P = 0.001) and 49.67 (47.22-52.12; P < 0.001), respectively, 1 year after renal TAE. Scores for abdominal fullness, poor appetite and heartburn showed marked improvement after renal TAE, while scores for fever, bodily pain and sleep disorder also improved slightly, but significantly. Scores for constipation and use of analgesics/sleeping medications/laxatives did not improve significantly. All of the SF-36 scores and the scores for specific symptoms (except bodily pain, snoring and constipation) were significantly correlated with the sequential decrease of the height-adjusted total kidney volume. In ADPKD patients on hemodialysis, renal TAE was effective in improving abdominal fullness, appetite, heartburn and SF-36 scores (MCS and RCS scores), but not for sleep disturbance, constipation and physical strength (PCS score). © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
Lee, I J; Kim, Y I; Kim, K W; Kim, D H; Ryoo, I; Lee, M W; Chung, J W
2012-11-01
This study was designed to evaluate the extent of the radiofrequency ablation zone in relation to the time interval between transcatheter arterial embolisation (TAE) and radiofrequency ablation (RFA) and, ultimately, to determine the optimal strategy of combining these two therapies for hepatocellular carcinoma. 15 rabbits were evenly divided into three groups: Group A was treated with RFA alone; Group B was treated with TAE immediately followed by RFA; and Group C was treated with TAE followed by RFA 5 days later. All animals underwent perfusion CT (PCT) scans immediately after RFA. Serum liver transaminases were measured to evaluate acute liver damage. Animals were euthanised for pathological analysis of ablated tissues 10 days after RFA. Non-parametric analyses were conducted to compare PCT indices, the RFA zone and liver transaminase levels among the three experimental groups. Group B showed a significantly larger ablation zone than the other two groups. Arterial liver perfusion and hepatic perfusion index represented well the perfusion decrease after TAE on PCT. Although Group B showed the most elevated liver transaminase levels at 1 day post RFA, the enzymes decreased to levels that were not different from the other groups at 10 days post-RFA. When combined TAE and RFA therapy is considered, TAE should be followed by RFA as quickly as possible, as it can be performed safely without serious hepatic deterioration, despite the short interval between the two procedures.
Potential for Bias When Estimating Critical Windows for Air Pollution in Children's Health.
Wilson, Ander; Chiu, Yueh-Hsiu Mathilda; Hsu, Hsiao-Hsien Leon; Wright, Robert O; Wright, Rosalind J; Coull, Brent A
2017-12-01
Evidence supports an association between maternal exposure to air pollution during pregnancy and children's health outcomes. Recent interest has focused on identifying critical windows of vulnerability. An analysis based on a distributed lag model (DLM) can yield estimates of a critical window that are different from those from an analysis that regresses the outcome on each of the 3 trimester-average exposures (TAEs). Using a simulation study, we assessed bias in estimates of critical windows obtained using 3 regression approaches: 1) 3 separate models to estimate the association with each of the 3 TAEs; 2) a single model to jointly estimate the association between the outcome and all 3 TAEs; and 3) a DLM. We used weekly fine-particulate-matter exposure data for 238 births in a birth cohort in and around Boston, Massachusetts, and a simulated outcome and time-varying exposure effect. Estimates using separate models for each TAE were biased and identified incorrect windows. This bias arose from seasonal trends in particulate matter that induced correlation between TAEs. Including all TAEs in a single model reduced bias. DLM produced unbiased estimates and added flexibility to identify windows. Analysis of body mass index z score and fat mass in the same cohort highlighted inconsistent estimates from the 3 methods. © The Author(s) 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Liang, Han-Sheng; Feng, Yi
2017-12-25
To observe the effect of transcutaneous acupoint electrical stimulation (TAES) on hemodynamic fluctuation caused by loosing tourniquet in the elderly patients undergoing knee joint replacement. A total of 60 ASA (America Society Anesthesiologist) I or II elderly patients for elective knee joint replacement surgery were randomly divided into control group (30 cases) and TAES group (30 cases). Patients of both groups were treated by intravenous anesthesia, and monitored with bispectral index (BIS, between 45-60) for anesthesia depth, stroke volume variation (SVV) for fluid management, mean arterial pressure (MAP) and cardiac index (CI) for hemodynamic fluctuation evaluation, and with analgesia nociception index (ANI, between 50-70) for remifentanil dosage adjustment. TAES (2 Hz/100 Hz, 8-20 mA) was applied to bilateral Xinshu (BL 15), Feishu (BL 13), Neiguan (PC 6) and Hegu (LI 4) acupoints for 30 min first (followed by anesthesia induction and operation), and given continuously until 15 min after tourniquet loosing. Patients of the control group were only given with electrodes attachment without electrical stimulation. The levels of MAP, CI, and arterial blood pH, PaCO 2 , PaO 2 , base excess (BE) and lactic acid (Lac) 1 min before, and 5 and 15 min after tourniquet loosing, and the dosages of remifentanil and ephedrine after tourniquet loosing were recorded. The changed levels of MAP, CI and blood Lac at 5 min after tourniquet loosing (relevant to the baseline levels), and blood Lac content at 15 min after tourniquet loosing (relevant to 5 min after tourniquet loosing) were significantly lower in the TAES group than in the control group ( P <0.05), but the levels of MAP and CI at 15 min after tourniquet loosing (relevant to 5 min following tourniquet loosing) were significantly higher in the TAES group than in the control group ( P <0.05), suggesting an improvement of blood pressure, cardiac function and substance metabolism after TAES. Moreover, the dosages of remifentanil and ephedrine after tourniquet loosing were considerably lower in the TAES group than in the control group ( P <0.05), suggesting a better stabilization of hemodynamics after TAES. No significant differences were found between the two groups in the levels of blood pH, PaCO 2 , PaO 2 and BE at 5 and 15 min after tourniquet loosing ( P >0.05). TAES has a positive effect on hemodynamics fluctuation caused by loosing tourniquet in the aged patients undergoing knee joint replacement.
Haga, Akira; Kawaji, Takahiro; Ideta, Ryuichi; Inomata, Yasuya; Tanihara, Hidenobu
2018-05-01
To compare the 1-year outcomes of treat-and-extend (TAE) and every-other-month (2M) regimens with intravitreal aflibercept in Japanese wet age-related macular degeneration (AMD) patients. Prospective, multicenter, randomized clinical trial. The primary outcome measure was the proportion of eyes in which the best-corrected visual acuity (BCVA) was maintained at week 52 [with a loss of <0.3 logarithm of minimum angular of resolution (logMAR) units]. The secondary outcome measures were the mean change from baseline in the central retinal thickness (CRT) and the number of injections. Forty-one patients were enrolled. The mean changes in the BCVA from baseline in the TAE and 2M were -0.32 ± 0.27 and -0.26 ± 0.30 logMAR units (p = 0.46). The TAE group was noninferior to the 2M group in BCVA maintenance. The mean CRT changes from baseline in the TAE and 2M were -161 ± 133 and -157 ± 90 μm (p = 0.73). The mean number of injections in the TAE and 2M were 7.5 ± 1.2 (range, 7-12) and 8.0 ± 0.0 (p < 0.0001). Treat-and-extend (TAE) regimen with aflibercept improved the BCVA and CRT to the same extent as 2M regimen, with a reduced number of injections. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Li, Yongjun; Ye, Xiaofen; Liu, Jinfeng; Zha, Jiping; Pei, Lin
2011-01-01
The echinoderm microtubule-associated protein-like 4-anaplastic lymphoma kinase (EML4-ALK) fusion gene resulting from an inversion within chromosome 2p occurs in approximately 5% of non-small cell lung cancer and is mutually exclusive with Ras and EGFR mutations. In this study, we have used a potent and selective ALK small molecule inhibitor, NPV-TAE684, to assess the oncogenic role of EML4-ALK in non-small cell lung cancer (NSCLC). We show here that TAE684 inhibits proliferation and induces cell cycle arrest, apoptosis, and tumor regression in two NSCLC models that harbor EML4-ALK fusions. TAE684 inhibits EML4-ALK activation and its downstream signaling including ERK, AKT, and STAT3. We used microarray analysis to carry out targeted pathway studies of gene expression changes in H2228 NSCLC xenograft model after TAE684 treatment and identified a gene signature of EML4-ALK inhibition. The gene signature represents 1210 known human genes, and the top biologic processes represented by these genes are cell cycle, DNA synthesis, cell proliferation, and cell death. We also compared the effect of TAE684 with PF2341066, a c-Met and ALK small molecule inhibitor currently in clinical trial in cancers harboring ALK fusions, and demonstrated that TAE684 is a much more potent inhibitor of EML4-ALK. Our data demonstrate that EML4-ALK plays an important role in the pathogenesis of a subset of NSCLC and provides insight into the mechanism of EML4-ALK inhibition by a small molecule inhibitor. PMID:21245935
78 FR 11728 - Aviation Rulemaking Advisory Committee; Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-19
... Working Groups a. Airman Testing Standards and Training Working Group (ARAC) b. Flight Controls Harmonization Working Group (Transport Airplane and Engine Subcommittee [TAE]) c. Airworthiness Assurance Working Group (TAE) 3. New Tasks a. Engine Bird Ingestion Requirements--Revision of Section 33.76 b...
Deconstructing the Spectrum of the Soft X-ray Background
NASA Technical Reports Server (NTRS)
Kuntz, K. D.; Snowden, S. L.
2000-01-01
The soft X-ray background in the 0.1-1.0 keV band is known to be produced by at least three sources; the Local Hot Bubble (LHB), the extragalactic power law (EPL), and a seemingly galactic component that lies outside the bulk of the absorption that is due to the ISM of the galactic disk. This last component, which we call the Trans-Absorption Emission (TAE), has been modeled by a number of groups who have derived disparate measures of its temperature. The differences have arisen from differing assumptions about the structure of the emitting gas and unrecognized methodological difficulties. In particular, spectral fitting methods do not uniquely separate the TAE from the foreground emission that is due the LHB. This "degeneracy" can be resolved using the angular variation of the absorption of the TAE. We show that the TAE cannot be characterized by a single thermal component; no single-component model can be consistent with both the spectral energy distribution of the TAE emission and the angular variation due to absorption by the galactic disk. We use the angular anticorrelation of the ROSAT All-Sky Survey with the galactic absorption to separate local from distant emission components, and to fit the spectral energy distribution of the resulting distant emission. We find that the emission is best described by a two-thermal-component model with logT(sub S) = 6.06(sup +0.14, sub -0.12) and log T(sub H) = 6.42(sup +0.14, sub -0.12). This two-thermal-component TAE fits the ROSAT spectral energy distribution significantly better than single-component models, and is consistent with both angular variation and spectral constraints.
Alamgir, Md; Eroukova, Veronika; Jessulat, Matthew; Xu, Jianhua; Golshani, Ashkan
2008-01-01
Background Functional genomics has received considerable attention in the post-genomic era, as it aims to identify function(s) for different genes. One way to study gene function is to investigate the alterations in the responses of deletion mutants to different stimuli. Here we investigate the genetic profile of yeast non-essential gene deletion array (yGDA, ~4700 strains) for increased sensitivity to paromomycin, which targets the process of protein synthesis. Results As expected, our analysis indicated that the majority of deletion strains (134) with increased sensitivity to paromomycin, are involved in protein biosynthesis. The remaining strains can be divided into smaller functional categories: metabolism (45), cellular component biogenesis and organization (28), DNA maintenance (21), transport (20), others (38) and unknown (39). These may represent minor cellular target sites (side-effects) for paromomycin. They may also represent novel links to protein synthesis. One of these strains carries a deletion for a previously uncharacterized ORF, YBR261C, that we term TAE1 for Translation Associated Element 1. Our focused follow-up experiments indicated that deletion of TAE1 alters the ribosomal profile of the mutant cells. Also, gene deletion strain for TAE1 has defects in both translation efficiency and fidelity. Miniaturized synthetic genetic array analysis further indicates that TAE1 genetically interacts with 16 ribosomal protein genes. Phenotypic suppression analysis using TAE1 overexpression also links TAE1 to protein synthesis. Conclusion We show that a previously uncharacterized ORF, YBR261C, affects the process of protein synthesis and reaffirm that large-scale genetic profile analysis can be a useful tool to study novel gene function(s). PMID:19055778
Alamgir, Md; Eroukova, Veronika; Jessulat, Matthew; Xu, Jianhua; Golshani, Ashkan
2008-12-03
Functional genomics has received considerable attention in the post-genomic era, as it aims to identify function(s) for different genes. One way to study gene function is to investigate the alterations in the responses of deletion mutants to different stimuli. Here we investigate the genetic profile of yeast non-essential gene deletion array (yGDA, approximately 4700 strains) for increased sensitivity to paromomycin, which targets the process of protein synthesis. As expected, our analysis indicated that the majority of deletion strains (134) with increased sensitivity to paromomycin, are involved in protein biosynthesis. The remaining strains can be divided into smaller functional categories: metabolism (45), cellular component biogenesis and organization (28), DNA maintenance (21), transport (20), others (38) and unknown (39). These may represent minor cellular target sites (side-effects) for paromomycin. They may also represent novel links to protein synthesis. One of these strains carries a deletion for a previously uncharacterized ORF, YBR261C, that we term TAE1 for Translation Associated Element 1. Our focused follow-up experiments indicated that deletion of TAE1 alters the ribosomal profile of the mutant cells. Also, gene deletion strain for TAE1 has defects in both translation efficiency and fidelity. Miniaturized synthetic genetic array analysis further indicates that TAE1 genetically interacts with 16 ribosomal protein genes. Phenotypic suppression analysis using TAE1 overexpression also links TAE1 to protein synthesis. We show that a previously uncharacterized ORF, YBR261C, affects the process of protein synthesis and reaffirm that large-scale genetic profile analysis can be a useful tool to study novel gene function(s).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanaka, Toshihiro, E-mail: toshihir@bf6.so-net.ne.jp; Isfort, Peter, E-mail: isfort@hia.rwth-aachen.de; Braunschweig, Till, E-mail: tbraunschweig@ukaachen.de
2013-06-15
Purpose. To evaluate the effects of particle size and course of action of superselective bland transcatheter arterial embolization (TAE) on the efficacy of radiofrequency ablation (RFA). Methods. Twenty pigs were divided into five groups: group 1a, 40-{mu}m bland TAE before RFA; group 1b, 40-{mu}m bland TAE after RFA; group 2a, 250-{mu}m bland TAE before RFA; group 2b, 250-{mu}m bland TAE after RFA and group 3, RFA alone. A total of 40 treatments were performed with a combined CT and angiography system. The sizes of the treated zones were measured from contrast-enhanced CTs on days 1 and 28. Animals were humanelymore » killed, and the treated zones were examined pathologically. Results. There were no complications during procedures and follow-up. The short-axis diameter of the ablation zone in group 1a (mean {+-} standard deviation, 3.19 {+-} 0.39 cm) was significantly larger than in group 1b (2.44 {+-} 0.52 cm; P = 0.021), group 2a (2.51 {+-} 0.32 cm; P = 0.048), group 2b (2.19 {+-} 0.44 cm; P = 0.02), and group 3 (1.91 {+-} 0.55 cm; P < 0.001). The greatest volume of ablation was achieved by performing embolization with 40-{mu}m particles before RFA (group 1a; 20.97 {+-} 9.65 cm{sup 3}). At histology, 40-{mu}m microspheres were observed to occlude smaller and more distal arteries than 250-{mu}m microspheres. Conclusion. Bland TAE is more effective before RFA than postablation embolization. The use of very small 40-{mu}m microspheres enhances the efficacy of RFA more than the use of larger particles.« less
Shin, Jong Soo; Shin, Ji Hoon; Ko, Heung-Kyu; Kim, Jong Woo; Yoon, Hyun-Ki
2016-01-01
PURPOSE We aimed to assess the safety and effectiveness of transcatheter arterial embolization (TAE) for mesenteric bleeding following trauma. METHODS From 2001 to 2015, 12 patients were referred to our interventional unit for mesenteric bleeding following trauma, based on clinical decisions and computed tomography (CT) images. After excluding one patient with no bleeding focus and one patient who underwent emergency surgery, a total of 10 patients (male:female ratio, 9:1; mean age, 52.1 years) who underwent super selective TAE of visceral arteries were included in this study. Technical and clinical success, complications, and 30-day mortality rate were analyzed. RESULTS In 10 patients who underwent TAE, the types of trauma were motor vehicle collision (n=6), fall (n=2), assault (n=1), and penetrating injury (n=1), and the bleeding arteries were in the pancreaticoduodenal arterial arcade (n=4), jejunal artery (n=3), colic artery (n=2), and sigmoid artery (n=1). N-butyl-2-cyanoacrylate (NBCA) (n=2), microcoils (n=2), and combinations of NBCA, microcoils, or gelatin sponge particles (n=6) were used as embolic agents. Technical success was achieved in all 10 patients, with immediate cessation of bleeding. Clinical success rate was 90% (9/10), and all patients were discharged with no further treatment required for mesenteric bleeding. However, one patient showed rebleeding 10 days later and underwent repeated TAE with successful result. There were no TAE-related ischemic complications such as bowel infarction. The 30-day mortality rate was 0%. CONCLUSION Our clinical experience suggests that TAE used to control mesenteric bleeding following trauma is safe and effective as a minimally invasive alternative to surgery. PMID:27306658
Kvannli, Line; Krohn, Jørgen
2017-11-01
To evaluate the visual outcome after transitioning from a pro re nata (PRN) intravitreal injection regimen to a treat-and-extend (TAE) regimen for patients with neovascular age-related macular degeneration (AMD). A retrospective review of patients who were switched from a PRN regimen with intravitreal injections of bevacizumab, ranibizumab or aflibercept to a TAE regimen. The best corrected visual acuity (BCVA), central retinal thickness (CRT) and type of medication used at baseline, at the time of changing treatment regimen and at the end of the study were analysed. Twenty-one eyes of 21 patients met the inclusion criteria. Prior to the switch, the patients received a mean of 13.8 injections (median, 10; range, 3-39 injections) with the PRN regimen for 44 months (range, 3-100 months), which improved the visual acuity in five patients (24%). After a mean of 6.1 injections (median, 5; range, 3-14 injections) with the TAE regimen over 8 months (range, 2-16 months), the visual acuity improved in 12 patients (57%). The improvement in visual acuity during treatment with the TAE regimen was statistically significant (p = 0.005). The proportion of patients with a visual acuity of 0.2 or better was significantly higher after treatment with the TAE regimen than after treatment with the PRN regimen (p = 0.048). No significant differences in CRT were found between the two treatment regimens. Even after prolonged treatment and a high number of intravitreal injections, switching AMD patients from a PRN regimen to a strict TAE regimen significantly improves visual acuity. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-17
... channel B manifold air pressure sensor hose permeability was not always recognized as a fault by the FADEC... States, on the relationship between the national Government and the States, or on the distribution of...
Analysis of Skin Humidity Variation Between Sasang Types
Jung, Soon-Oh; Park, Soo-Jin; Chae, Han; Park, Soo Hyun; Hwang, Minwoo; Kim, Sang-Hyuk
2009-01-01
The purpose of this study was to examine the relationship between variations in skin humidity (SH) induced by perspiration across Sasang types and to identify novel and effective Sasang classification factors. We also analyzed the responses of each Sasang type to sweating-related QSCC II items. The results revealed a significant difference in SH across gender and significant differences in SH before and after perspiration between Tae-Eum and So-Eum men. In addition, Tae-Eum women showed significant differences in SH compared with women classified as another Sasang type. Furthermore, evaluation of the items related to sweating in the QSCC II and their relationship to each constitution revealed a significant difference between Tae-Eum and other Sasang types. Overall, the results of this study indicate that there is a distinct SH difference following perspiration between Tae-Eum and other Sasang types. Such findings may aid in Sasang typology diagnostic testing with the support of further sophisticated clinical studies. PMID:19745016
Yan, Jie-yu; Wang, Mao-qiang; Liu, Feng-yong; Wang, Zhi-jun; Duan, Feng; Song, Peng
2012-11-06
To evaluate the efficiency and safety of transcatheter arterial embolization (TAE) for treatment of focal nodular hyperplasia (FNH). From January 2005 to December 2010, super selective TAE was performed for 21 patients with FNH. The patients consisted of 16 men and 5 women with age range of 16 to 44 years (mean age, 28 ± 12). Liver contrast enhancement CT and ultrasonography (US) were performed in all patients, dynamic contrast enhancement MRI was performed in 17 patients. All patients underwent percutaneous needle biopsies and the diagnosis of FNH was proven histologically. The indications for TAE were patients with progressive increase in size of FNH, who were not candidates for surgical treatment, or who refused for surgery. Embolic materials used in this series included emulsion of iodized oil and bleomycin and polyvinyl alcohol particle (PVA). Follow-up examinations included the routine blood tests, liver and renal function tests, US, CT or MRI. Eighteen patients (85.7%) had a single solitary focus and 3 (14.3%) had multiple foci. The diameter of the mass varied from 3.5 cm to 9.5 cm with a mean of 5.5 cm (5.5 ± 3.0 cm). All patients presented angiographically with characteristic findings, such as feeding artery that was distributed with a spinning wheel appearance, an extensive hypervascular mass, without arterio-venous shunt or portal vein invasion. A single session of TAE was performed in all patients. Technical success of TAE was achieved in all cases. No major complications were encountered in any of our patients. All patients were regularly followed up ranging from 1 to 6 years (3.5 ± 2.0) and they were healthy without recurrence. Marked reduction in the size of the FNH without arterial blood supply was found in 16 patients, and almost complete resolution of the FNH was observed in 6 patients. TAE is a safe and effective therapy for the management of patients with FNH. TAE could control FNH very well and even could be considered as a radical treatment.
2013-01-01
Background A common dilemma in the management of pelvic fractures is recognizing the presence of associated abdominal injury. The purpose of this study was to determine the association between initial therapeutic intervention (laparotomy or transcatheter arterial embolization (TAE)) and mortality. Methods This was a cohort study using the Japan Trauma Data Bank between 2004 and 2010, including blunt trauma patients with pelvic fractures and positive Focused Assessment with Sonography in Trauma (FAST) results. Eligible patients were restricted to those who underwent laparotomy or TAE/angiography as the initial therapeutic intervention. Crude and adjusted odds ratio (AOR) for in-hospital mortality were compared between the laparotomy first and TAE first groups (reference group). Multiple logistic regression analysis and propensity score adjusted analysis were used to adjust for clinically relevant confounders, including the severity of injury. Results Of the 317 participants, 123 patients underwent laparotomy first and 194 patients underwent TAE first. The two groups were similar in terms of age, although the laparotomy first group had higher mean Injury Severity Scores (ISS) and higher mean scores based on the abdominal Abbreviated Injury Scale (AIS), as well as lower mean pelvic AIS and systolic blood pressure (SBP). Half of the patients who were hypotensive (SBP < 90 mmHg) on arrival underwent TAE first. The laparotomy first group had a significantly higher crude in-hospital mortality (41% vs. 27%; P < 0.01). After adjusting for confounders, the choice of initial therapeutic intervention did not affect the in-hospital mortality (AOR, 1.20; 95% Confidence Interval (CI), 0.61-2.39). Even in the limited subgroup of hypotensive patients (SBP 66–89 mmHg and SBP < 65 mmHg subgroup), the effect was similar (AOR, 1.50; 95% CI, 0.56-4.05 and AOR, 1.05; 95% CI, 0.44-3.03). Conclusions In Japan, laparotomy and TAE are equally chosen as the initial therapeutic intervention regardless of hemodynamic status. No significant difference was seen between the laparotomy first and TAE first groups regarding in-hospital mortality. PMID:24299060
Border-ownership-dependent tilt aftereffect in incomplete figures
NASA Astrophysics Data System (ADS)
Sugihara, Tadashi; Tsuji, Yoshihisa; Sakai, Ko
2007-01-01
A recent physiological finding of neural coding for border ownership (BO) that defines the direction of a figure with respect to the border has provided a possible basis for figure-ground segregation. To explore the underlying neural mechanisms of BO, we investigated stimulus configurations that activate BO circuitry through psychophysical investigation of the BO-dependent tilt aftereffect (BO-TAE). Specifically, we examined robustness of the border ownership signal by determining whether the BO-TAE is observed when gestalt factors are broken. The results showed significant BO-TAEs even when a global shape was not explicitly given due to the ambiguity of the contour, suggesting a contour-independent mechanism for BO coding.
Border-ownership-dependent tilt aftereffect in incomplete figures.
Sugihara, Tadashi; Tsuji, Yoshihisa; Sakai, Ko
2007-01-01
A recent physiological finding of neural coding for border ownership (BO) that defines the direction of a figure with respect to the border has provided a possible basis for figure-ground segregation. To explore the underlying neural mechanisms of BO, we investigated stimulus configurations that activate BO circuitry through psychophysical investigation of the BO-dependent tilt aftereffect (BO-TAE). Specifically, we examined robustness of the border ownership signal by determining whether the BO-TAE is observed when gestalt factors are broken. The results showed significant BO-TAEs even when a global shape was not explicitly given due to the ambiguity of the contour, suggesting a contour-independent mechanism for BO coding.
Display management subsystem, version 1: A user's eye view
NASA Technical Reports Server (NTRS)
Parker, Dolores
1986-01-01
The structure and application functions of the Display Management Subsystem (DMS) are described. The DMS, a subsystem of the Transportable Applications Executive (TAE), was designed to provide a device-independent interface for an image processing and display environment. The system is callable by C and FORTRAN applications, portable to accommodate different image analysis terminals, and easily expandable to meet local needs. Generic applications are also available for performing many image processing tasks.
1987-04-01
title of the study. This document. may be reproduced for use in other resetrch reports or educational pursuits contingent upon the fol ,owiog...stipulations: -- t’pr,,duCL n ri ;,|ht s do not extend to any copyrighted material that may be contained in the research report . A: r .pr)t uc d copi es inu:-st...s) o: tae report’s author(s). -- t for’nat mo.,i ficat ion is necessary to better serv, !,ie user’:; ieeds, adjustments may be made to tnis report
78 FR 57672 - Aviation Rulemaking Advisory Committee Meeting on Transport Airplane and Engine Issues
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-19
... Committee Meeting on Transport Airplane and Engine Issues AGENCY: Federal Aviation Administration (FAA), DOT... Rulemaking Advisory Committee (ARAC) Transport Airplane and Engine (TAE) Subcommittee to discuss TAE issues... meeting is as follows: Opening Remarks, Review Agenda and Minutes FAA Report ARAC Report Transport Canada...
Transportable Applications Environment Plus, Version 5.1
NASA Technical Reports Server (NTRS)
1994-01-01
Transportable Applications Environment Plus (TAE+) computer program providing integrated, portable programming environment for developing and running application programs based on interactive windows, text, and graphical objects. Enables both programmers and nonprogrammers to construct own custom application interfaces easily and to move interfaces and application programs to different computers. Used to define corporate user interface, with noticeable improvements in application developer's and end user's learning curves. Main components are; WorkBench, What You See Is What You Get (WYSIWYG) software tool for design and layout of user interface; and WPT (Window Programming Tools) Package, set of callable subroutines controlling user interface of application program. WorkBench and WPT's written in C++, and remaining code written in C.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basile, Antonio; Medina, Jose Garcia; Mundo, Elena
We report a case of concurrent rectus sheath and psoas hematomas in a patient undergoing anticoagulant therapy, treated by transcatheter arterial embolization (TAE) of inferior epigastric and lumbar arteries. Computed tomography (CT) demonstrated signs of active bleeding in two hematomas of the anterior and posterior abdominal walls. Transfemoral arteriogram confirmed the extravasation of contrast from the right inferior epigastric artery (RIEA). Indirect signs of bleeding were also found in a right lumbar artery (RLA). We successfully performed TAE of the feeding arteries. There have been few reports in the literature of such spontaneous hemorrhages in patients undergoing anticoagulation, successfully treatedmore » by TAE.« less
How visual short-term memory maintenance modulates subsequent visual aftereffects.
Saad, Elyana; Silvanto, Juha
2013-05-01
Prolonged viewing of a visual stimulus can result in sensory adaptation, giving rise to perceptual phenomena such as the tilt aftereffect (TAE). However, it is not known if short-term memory maintenance induces such effects. We examined how visual short-term memory (VSTM) maintenance modulates the strength of the TAE induced by subsequent visual adaptation. We reasoned that if VSTM maintenance induces aftereffects on subsequent encoding of visual information, then it should either enhance or reduce the TAE induced by a subsequent visual adapter, depending on the congruency of the memory cue and the adapter. Our results were consistent with this hypothesis and thus indicate that the effects of VSTM maintenance can outlast the maintenance period.
Nonlinear dynamics of toroidal Alfvén eigenmodes in presence of tearing modes
NASA Astrophysics Data System (ADS)
Zhu, Jia; Ma, Zhiwei; Wang, Sheng; Zhang, Wei
2016-10-01
A new hybrid kinetic-MHD code CLT-K is developed to study nonlinear dynamics of n =1 toroidal Alfvén eigenmodes (TAEs) with the m/n =2/1 tearing mode. It is found that the n =1 TAE is first excited by isotropic energetic particles in the earlier stage and reaches the steady state due to wave-particle interaction. After the saturation of the n =1 TAE, the tearing mode intervenes and triggers the second growth of the mode. The modes goes into the second steady state due to multiple tearing mode-mode nonlinear coupling. Both wave-particle and wave-wave interactions are observed in our hybrid simulation.
Tae Kwon Do and Adolescent Psychosocial Development
ERIC Educational Resources Information Center
Budd, Ronald Reaco
2013-01-01
The following research was completed in an attempt to document the existence of any correlation between youth participation in Tae Kwon Do and various psychological and social traits evident within the participants. The data of this dissertation was gathered and recorded within the format of the qualitative case study. At the end of the case study…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-23
... receipt. List of Subjects in 14 CFR Part 39 Air transportation, Aircraft, Aviation safety, Incorporation... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration 14 CFR Part 39 [Docket No. FAA-2009... Operations office is located at Docket Management Facility, U.S. Department of Transportation, 1200 New...
77 FR 13488 - Airworthiness Directives; Thielert Aircraft Engines GmbH (TAE) Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-07
... Airworthiness Directives; Thielert Aircraft Engines GmbH (TAE) Reciprocating Engines AGENCY: Federal Aviation... this AD, contact Thielert Aircraft Engines GmbH, Platanenstrasse 14 D-09350, Lichtenstein, Germany... following new AD: 2010-11-09R1 Thielert Aircraft Engines GmbH: Amendment 39-16972; Docket No. FAA-2009-0201...
Useful measures and models for analytical quality management in medical laboratories.
Westgard, James O
2016-02-01
The 2014 Milan Conference "Defining analytical performance goals 15 years after the Stockholm Conference" initiated a new discussion of issues concerning goals for precision, trueness or bias, total analytical error (TAE), and measurement uncertainty (MU). Goal-setting models are critical for analytical quality management, along with error models, quality-assessment models, quality-planning models, as well as comprehensive models for quality management systems. There are also critical underlying issues, such as an emphasis on MU to the possible exclusion of TAE and a corresponding preference for separate precision and bias goals instead of a combined total error goal. This opinion recommends careful consideration of the differences in the concepts of accuracy and traceability and the appropriateness of different measures, particularly TAE as a measure of accuracy and MU as a measure of traceability. TAE is essential to manage quality within a medical laboratory and MU and trueness are essential to achieve comparability of results across laboratories. With this perspective, laboratory scientists can better understand the many measures and models needed for analytical quality management and assess their usefulness for practical applications in medical laboratories.
Transcatheter Arterial Embolization of Intramuscular Active Hemorrhage with N-Butyl Cyanoacrylate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoo, Dong Hyun; Jae, Hwan Jun, E-mail: jhj@radiol.snu.ac.kr; Kim, Hyo-Cheol
Purpose: This study was designed to evaluate the clinical efficacy and safety of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate (NBCA) for intramuscular active hemorrhage of varied etiologies and anatomic sites. Methods: Eighteen patients who demonstrated hematoma with pseudoaneurysm and/or active extravasation of contrast media underwent TAE with NBCA. Etiologies of hematoma included trauma, postoperative complication, and coagulopathy (due to underlying disease or anticoagulation therapy). Sites of embolization included chest wall, abdomen wall, retroperitoneum, and extremity. TAE was performed by using 1:3 to 1:5 mixtures of NBCA and iodized oil, either solely (n = 15) or in combination with microcoilmore » (n = 3). The technical and clinical success rate, procedure-related complications, and clinical outcomes were evaluated. Results: The technical and clinical success rates were 100% and 83% (15/18), respectively. Two patients expired while admitted due to other comorbidities. One patient expired due to recurrent bleeding at another site. There were no serious complications relating to the embolization procedure. Conclusions: TAE with NBCA is effective and safe treatment modality for intramuscular active hemorrhage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lv Mingming, E-mail: lvmingming001@163.com; Fan, Xin-dong, E-mail: fanxindong@yahoo.com.cn; Su Lixin, E-mail: sulixin1975@126.com
2013-02-15
ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20-25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Controlmore » angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.« less
Mitigation of Alfvenic activity by 3D magnetic perturbations on NSTX
Kramer, G. J.; Bortolon, A.; Ferraro, N. M.; ...
2016-07-05
Observations on the National Spherical Torus eXperiment (NSTX) indicate that externally applied non-axisymmetric magnetic perturbations (MP) can reduce the amplitude of Toroidal Alfven Eigenmodes (TAE) and Global Alfven Eigenmodes (GAE) in response to pulsed n=3 non-resonant fields. From full-orbit following Monte Carlo simulations with the 1- and 2-fluid resistive MHD plasma response to the magnetic perturbation included, it was found that in response to MP pulses the fast-ion losses increased and the fast-ion drive for the GAEs was reduced. The MP did not affect the fast-ion drive for the TAEs significantly but the Alfven continuum at the plasma edge wasmore » found to be altered due to the toroidal symmetry breaking which leads to coupling of different toroidal harmonics. The TAE gap was reduced at the edge creating enhanced continuum damping of the global TAEs, which is consistent with the observations. Furthermore, the results suggest that optimized non-axisymmetric MP might be exploited to control and mitigate Alfven instabilities by tailoring the fast-ion distribution function and/or continuum structure.« less
NASA Astrophysics Data System (ADS)
Hou, Yawei; Zhu, Ping; Zou, Zhihui; Kim, Charlson C.; Hu, Zhaoqing; Wang, Zhengxiong
2016-10-01
The energetic-particle (EP) driven toroidal Alfvén eigenmodes (TAEs) in a circular-shaped large aspect ratio tokamak are studied using the hybrid kinetic-MHD model in the NIMROD code, where the EPs are advanced using the δf particle-in-cell (PIC) method and their kinetic effects are coupled to the bulk plasma through moment closures. Two initial distributions of EPs, Maxwell and slowing-down, are considered. The influence of EP parameters, including density, temperature and density gradient, on the frequency and the growth rate of TAEs are obtained and benchmarked with theory and gyrokinetic simulations for the Maxwell distribution with good agreement. When the density and temperature of EPs are above certain thresholds, the transition from TAE to energetic particle modes (EPM) occurs and the mode structure also changes. Comparisons between Maxwell and slowing-down distributions in terms of EP-driven TAEs and EPMs will also be presented and discussed. Supported by the National Magnetic Confinement Fusion Science Program of China Grant Nos. 2014GB124002 and 2015GB101004, and the Natural Science Foundation of China Grant No. 11205194.
Transcatheter arterial embolization of acute gastrointestinal tumor hemorrhage with Onyx.
Sun, C J; Wang, C E; Wang, Y H; Xie, L L; Liu, T H; Ren, W C
2015-02-01
Endovascular embolization has been used to control gastrointestinal tumor bleeding. Lots of embolic agents have been applied in embolization, but liquid embolic materials such as Onyx have been rarely used because of concerns about severe ischemic complications. To evaluate the clinical efficacy and safety of transcatheter arterial embolization (TAE) with Onyx for acute gastrointestinal tumor hemorrhage. Between September 2011 and July 2013, nine patients were diagnosed as acute gastrointestinal tumor hemorrhage by clinical feature and imaging examination. The angiographic findings were extravasation of contrast media in the five patients. The site of hemorrhage included upper gastrointestinal bleeding in seven cases and lower gastrointestinal bleeding in two cases. TAE was performed using Onyx in all the patients, and the blood pressure and heart rate were monitored, the angiographic and clinical success rate, recurrent bleeding rate, procedure related complications and clinical outcomes were evaluated after therapy. The clinical parameters and embolization data were studied retrospectively. All the patients (100%) who underwent TAE with Onyx achieved complete hemostasis without rebleeding and the patients were discharged after clinical improvement without a second surgery. No one of the patients expired during the hospital course. All the patients were discharged after clinical improvement without a second surgery. Postembolization bowel ischemia or necrosis was not observed in any of the patients who received TAE with Onyx. TAE with Onyx is a highly effective and safe treatment modality for acute gastrointestinal tumor hemorrhage, even with pre-existing coagulopathy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slaby, Christoph; Könies, Axel; Kleiber, Ralf
2016-09-15
The resonant interaction of shear Alfvén waves with energetic particles is investigated numerically in tokamak and stellarator geometry using a non-perturbative MHD-kinetic hybrid approach. The focus lies on toroidicity-induced Alfvén eigenmodes (TAEs), which are most easily destabilized by a fast-particle population in fusion plasmas. While the background plasma is treated within the framework of an ideal-MHD theory, the drive of the fast particles, as well as Landau damping of the background plasma, is modelled using the drift-kinetic Vlasov equation without collisions. Building on analytical theory, a fast numerical tool, STAE-K, has been developed to solve the resulting eigenvalue problem usingmore » a Riccati shooting method. The code, which can be used for parameter scans, is applied to tokamaks and the stellarator Wendelstein 7-X. High energetic-ion pressure leads to large growth rates of the TAEs and to their conversion into kinetically modified TAEs and kinetic Alfvén waves via continuum interaction. To better understand the physics of this conversion mechanism, the connections between TAEs and the shear Alfvén wave continuum are examined. It is shown that, when energetic particles are present, the continuum deforms substantially and the TAE frequency can leave the continuum gap. The interaction of the TAE with the continuum leads to singularities in the eigenfunctions. To further advance the physical model and also to eliminate the MHD continuum together with the singularities in the eigenfunctions, a fourth-order term connected to radiative damping has been included. The radiative damping term is connected to non-ideal effects of the bulk plasma and introduces higher-order derivatives to the model. Thus, it has the potential to substantially change the nature of the solution. For the first time, the fast-particle drive, Landau damping, continuum damping, and radiative damping have been modelled together in tokamak- as well as in stellarator geometry.« less
Brun, Julien; Guillot, Stéphanie; Bouzat, Pierre; Broux, Christophe; Thony, Frédéric; Genty, Céline; Heylbroeck, Christophe; Albaladejo, Pierre; Arvieux, Catherine; Tonetti, Jérôme; Payen, Jean-Francois
2014-01-01
The early diagnosis of pelvic arterial haemorrhage is challenging for initiating treatment by transcatheter arterial embolization (TAE) in multiple trauma patients. We use an institutional algorithm focusing on haemodynamic status on admission and on a whole-body CT scan in stabilized patients to screen patients requiring TAE. This study aimed to assess the effectiveness of this approach. This retrospective cohort study included 106 multiple trauma patients admitted to the emergency room with serious pelvic fracture [pelvic abbreviated injury scale (AIS) score of 3 or more]. Of the 106 patients, 27 (25%) underwent pelvic angiography leading to TAE for active arterial haemorrhage in 24. The TAE procedure was successful within 3h of arrival in 18 patients. In accordance with the algorithm, 10 patients were directly admitted to the angiography unit (n=8) and/or operating room (n=2) for uncontrolled haemorrhagic shock on admission. Of the remaining 96 stabilized patients, 20 had contrast media extravasation on pelvic CT scan that prompted pelvic angiography in 16 patients leading to TAE in 14. One patient underwent a pelvic angiography despite showing no contrast media extravasation on pelvic CT scan. All 17 stabilized patients who underwent pelvic angiography presented a more severely compromised haemodynamic status on admission, and they required more blood products during their initial management than the 79 patients who did not undergo pelvic angiography. The incidence of unstable pelvic fractures was however comparable between the two groups. Overall, haemodynamic instability and contrast media extravasation on the CT-scan identified 26 out of the 27 patients who required subsequent pelvic angiography leading to TAE in 24. An algorithm focusing on haemodynamic status on arrival and on the whole-body CT scan in stabilized patients may be effective at triaging multiple trauma patients with serious pelvic fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yonemitsu, Takafumi; Kawai, Nobuyuki; Sato, Morio, E-mail: morisato@mail.wakayama-med.ac.jp
2010-12-15
This study was designed to compare the efficacy of transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) or gelatin sponge particles (GSP) for acute arterial bleeding in a coagulopathic condition using a swine model. Four healthy swine were divided into two coagulopathic conditions: mild and severe. Five hemorrhages were created in each swine (10 hemorrhages per coagulopathy). Mild coagulopathy was achieved by bloodletting 10% of the total circulatory whole blood and preserving activated clotting time (ACT) less than 200 s (ACT < 200 s state); severe coagulopathy was achieved by bloodletting 30% and preserving ACT > 400 s (ACT >more » 400-second state). For each state, of ACT < 200 s or ACT > 400 s, TAE was conducted with GSP or NBCA to control five hemorrhages arising from artificially created renal and splenic injuries. Angiography immediately after TAE with GSP or NBCA showed complete occlusion in both coagulopathic conditions. In the ACT < 200-second state, follow-up angiography at 5-30 min after TAE with GSP or NBCA showed no evidence of recurrent hemorrhage. In the ACT > 400-second state, follow-up angiography showed recurrent hemorrhage in four (80%) of the five hemorrhages embolized with GSP and in one (20%) of the five hemorrhages embolized with NBCA. Microscopically, red thrombi were observed densely surrounding GSP in mild coagulopathy but were scarce in severe coagulopathy. In a condition with severe coagulopathy, TAE with NBCA was more effective in durability to cease active arterial bleeding than with GSP.« less
Tanikawa, K; Hirai, K; Kawazoe, Y; Yamashita, K; Kumagai, M; Abe, M
1985-10-01
407 cases of unresectable hepatocellular carcinoma (HCC) occurring from 1970 to March 1985, including 107 cases receiving conservative therapy, 176 cases receiving one-shot therapy and 124 cases receiving transcatheter arterial embolization (TAE) therapy, were studied and the efficacy of chemotherapy was compared with that of TAE therapy. The results were as follows; One-year survival rate was 2.8% with a median survival time of 1.3 months in conservative therapy. In the 176 cases of one-shot therapy, one-year survival rate was 21.0%, two-year 6.8% and three-year 2.3% and the median survival time was 4.8% months. In 120 cases of one-shot therapy which were compatible with criteria for one-shot injection of anticancer drugs via the hepatic artery for HCC, one-year survival rate was 30%. However the rate was 1.8% in 56 cases which were not compatible with the criteria. In 37 cases in which Mitomycin C (MMC) and Adriamycin (ADR) were administered alternately, one-year survival rate was 41.7%, two-year 16.1% and three-year 4.3%. The highest survival rate was obtained by TAE therapy. One-year survival rate was 66.9%, two-year 33.8% and three-year 28.9%. Decrease of AFP after therapy was noted in 42.4% of cases given one-shot therapy and in 95.2% of cases given TEA therapy. The results suggest that alternate administration of anticancer agents produces good chemotherapeutic effects and that the best life-prolongation is obtained by TAE therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okada, Takuya, E-mail: okabone@gmail.com; Yamaguchi, Masato; Takahashi, Takuya
Purpose: This study was designed to evaluate the safety of selective transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) in a swine model in terms of histological changes in the pancreas. Methods: Three groups of two female swine (58-64 kg) per group underwent TAE of the dorsal pancreatic artery, under anesthesia, with 1:1, 1:4, and 1:9 mixtures of NBCA and iodized oil. Blood parameters were evaluated at days 1, 4, and 10 after TAE, after which the animals were sacrificed and pancreatic tissues were examined under light microscopy. Results: All of the animals were asymptomatic and survived for 10 days.more » Cone beam computed tomographic angiography revealed occlusion of the dorsal pancreatic artery and no enhancement in the embolized area. The white blood cell count and C-reactive protein level were elevated slightly on day 1 after TAE (mean {+-} SD: 252.7 {+-} 27.8 Multiplication-Sign 10{sup 2}/{mu}l and 0.15 {+-} 0.07 mg/l, respectively), but they normalized or remained near the upper normal limit thereafter. The serum amylase and lipase levels also were elevated on day 1 (8831.7 {+-} 2169.2 U/l and 130 {+-} 53.4 U/l, respectively) but normalized thereafter. Histologically, necrosis and fibrosis were noted only in the embolized segment, and necrosis and acute inflammatory reactions were absent in the nonembolized segment. The border between both segments was well defined. Lymphocytic infiltration and foreign body reaction were noted around the embolized vessels. Conclusions: Selective TAE with NBCA in the pancreas caused localized ischemic necrosis without clinically significant pancreatitis; therefore, this procedure is tolerable in swine.« less
Yonemitsu, Takafumi; Kawai, Nobuyuki; Sato, Morio; Sonomura, Tetsuo; Takasaka, Isao; Nakai, Motoki; Minamiguchi, Hiroki; Sahara, Shinya; Iwasaki, Yasuhiro; Naka, Toshio; Shinozaki, Masahiro
2010-12-01
This study was designed to compare the efficacy of transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) or gelatin sponge particles (GSP) for acute arterial bleeding in a coagulopathic condition using a swine model. Four healthy swine were divided into two coagulopathic conditions: mild and severe. Five hemorrhages were created in each swine (10 hemorrhages per coagulopathy). Mild coagulopathy was achieved by bloodletting 10% of the total circulatory whole blood and preserving activated clotting time (ACT) less than 200 s (ACT < 200 s state); severe coagulopathy was achieved by bloodletting 30% and preserving ACT > 400 s (ACT > 400-second state). For each state, of ACT < 200 s or ACT > 400 s, TAE was conducted with GSP or NBCA to control five hemorrhages arising from artificially created renal and splenic injuries. Angiography immediately after TAE with GSP or NBCA showed complete occlusion in both coagulopathic conditions. In the ACT < 200-second state, follow-up angiography at 5-30 min after TAE with GSP or NBCA showed no evidence of recurrent hemorrhage. In the ACT > 400-second state, follow-up angiography showed recurrent hemorrhage in four (80%) of the five hemorrhages embolized with GSP and in one (20%) of the five hemorrhages embolized with NBCA. Microscopically, red thrombi were observed densely surrounding GSP in mild coagulopathy but were scarce in severe coagulopathy. In a condition with severe coagulopathy, TAE with NBCA was more effective in durability to cease active arterial bleeding than with GSP.
Popov, Milen; Sotiriadis, Charalampos; Gay, Frederique; Jouannic, Anne-Marie; Lachenal, Yann; Hajdu, Steven D; Doenz, Francesco; Qanadli, Salah D
2017-04-01
To report our experience using a multilevel patient management algorithm to direct transarterial embolization (TAE) in managing spontaneous intramuscular hematoma (SIMH). From May 2006 to January 2014, twenty-seven patients with SIMH had been referred for TAE to our Radiology department. Clinical status and coagulation characteristics of the patients are analyzed. An algorithm integrating CT findings is suggested to manage SIMH. Patients were classified into three groups: Type I, SIMH with no active bleeding (AB); Type II, SIMH with AB and no muscular fascia rupture (MFR); and Type III, SIMH with MFR and AB. Type II is furthermore subcategorized as IIa, IIb and IIc. Types IIb, IIc and III were considered for TAE. The method of embolization as well as the material been used are described. Continuous variables are presented as mean ± SD. Categorical variables are reported as percentages. Technical success, clinical success, complications and 30-day mortality (d30 M) were analyzed. Two patients (7.5%) had Type IIb, four (15%) Type IIc and 21 (77.5%) presented Type III. The detailed CT and CTA findings, embolization procedure and materials used are described. Technical success was 96% with a complication rate of 4%. Clinical success was 88%. The bleeding-related thirty-day mortality was 15% (all with Type III). TAE is a safe and efficient technique to control bleeding that should be considered in selected SIMH as soon as possible. The proposed algorithm integrating CT features provides a comprehensive chart to select patients for TAE. 4.
Bhat, Owais Mohammad; Kumar, P Uday; Rao, K Rajender; Ahmad, Ashfaq; Dhawan, Veena
2018-04-01
Terminalia arjuna is a medicinal plant well known as a cardiotonic in Ayurvedic system of medicine. We hypothesized that aqueous stem bark extract of T. arjuna (TAE) may inhibit IL-18-induced atherosclerosis via NF-κB/PPAR-γ-mediated pathway in Apo E-/- mice. 12-week-old, male Apo E-/- mice divided into four groups (n = 6/group) fed with normal chow-diet were employed: GP I: phosphate buffer saline (PBS) (2 month); GP II: rIL-18 (1 month) followed by PBS (1 month); GP III: rIL-18 (1 month) followed by TAE (1 month); GP IV: rIL-18 (1 month) followed by atorvastatin (1 month). IL-18 treatment induced a significant increase (p < 0.001) in pro-inflammatory marker (IL-18) (170 ± 9.16 vs. 1178.66 ± 8.08, pg/ml), and downregulated cholesterol efflux gene (PPAR-γ) by ~0.6-fold vs. 1.00 in IL-18-treated mice as compared to the control animals, respectively. TAE treatment to both groups caused a significant reduction in IL-18 to 281.66 ± 9.60 vs. 1178.66 ± 8.08 (pg/ml), upregulated cholesterol efflux gene by ~1.5- vs. 0.6-fold in TAE-treated group, decreased atherogenic lipids, and percentage atherosclerotic lesion area, demonstrating comparable effects with atorvastatin. Our data demonstrate that TAE protects against IL-18-induced atherosclerosis via NF-κB/PPAR-γ-mediated pathway.
Operation Stabilise: U.S. Joint Force Operations in East Timor
2001-04-01
September 1999, while deliberating the issue, Adm Blair designated the USS Mobile Bay (CG 53) and the USNS Kilauea (T-AE 26) as Joint Task Force-Timor Sea...Timor Sea Operations, 7th Fleet, Pacific Fleet § USS MOBILE BAY (CG 53), CJTF TSO (CAPT Edward Rogers, USN) § USNS KILAUEA (T-AE 26) § USNS SAN JOSE (T
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-13
... Airworthiness Directives; Thielert Aircraft Engines GmbH Model TAE 125-01 Reciprocating Engines AGENCY: Federal...-18300R5, may cause a blow-by gas pressure increase inside the crankcase of the engine in excess of the oil seal design pressure limits. Leaking engine oil may adversely affect the gearbox clutch or the engine...
77 FR 4217 - Airworthiness Directives; Thielert Aircraft Engines GmbH Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-27
... sensitivity of friction disk Part Number (P/N) 05-7211- K010201 against possible misalignment of gearbox and..., Thielert Aircraft Engines GmbH has developed a new friction disk. We issued a notice of proposed rulemaking... all TAE 125-02-99 and TAE 125-02-114 reciprocating engines, replacing the friction disk, P/N 05- 7211...
Kennicutt, A R; Morkowchuk, L; Krein, M; Breneman, C M; Kilduff, J E
2016-08-01
A quantitative structure-activity relationship was developed to predict the efficacy of carbon adsorption as a control technology for endocrine-disrupting compounds, pharmaceuticals, and components of personal care products, as a tool for water quality professionals to protect public health. Here, we expand previous work to investigate a broad spectrum of molecular descriptors including subdivided surface areas, adjacency and distance matrix descriptors, electrostatic partial charges, potential energy descriptors, conformation-dependent charge descriptors, and Transferable Atom Equivalent (TAE) descriptors that characterize the regional electronic properties of molecules. We compare the efficacy of linear (Partial Least Squares) and non-linear (Support Vector Machine) machine learning methods to describe a broad chemical space and produce a user-friendly model. We employ cross-validation, y-scrambling, and external validation for quality control. The recommended Support Vector Machine model trained on 95 compounds having 23 descriptors offered a good balance between good performance statistics, low error, and low probability of over-fitting while describing a wide range of chemical features. The cross-validated model using a log-uptake (qe) response calculated at an aqueous equilibrium concentration (Ce) of 1 μM described the training dataset with an r(2) of 0.932, had a cross-validated r(2) of 0.833, and an average residual of 0.14 log units.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... permeability is not always recognized as fault by the FADEC. The MAP value measured by the sensor may be lower... channel B manifold air pressure (MAP) sensor hose permeability is not always recognized as fault by the... between the national Government and the States, or on the distribution of power and responsibilities among...
Troubleshooting Assessment and Enhancement (TAE) Program: Test and Evaluation
1991-04-01
Navy Personnel Research and Development Center San Diego, California 92152-6800 TN-91-13 April 1991 AD-A23 6 323 Troubleshooting Assessment and...00002 NPRDC-TN-91-13 April 1991 Troubleshooting Assessment and Enhancement (TAE) Program: Test and Evaluation Harry B. Conner Navy Personnel Research ...McLachlan Director, Training Systems Department Approved for public release; distribution is unlimited. Navy Personnel Research and Development Center
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-31
...: Service experience has shown that a case of FADEC channel B manifold air pressure (MAP) sensor hose... combustion chamber and thus the available power of the engine. A change in FADEC software version 2.91 will..., previous software versions allow--under certain conditions and on DA 42 aircraft only--the initiation of a...
Ramin, Séverin; Hermida, Margaux; Millet, Ingrid; Murez, Thibault; Monnin, Valérie; Hamoui, Mazen; Capdevila, Xavier; Charbit, Jonathan
2018-06-12
The objective was to assess the predictive performance of different intravascular contrast extravasation (ICE) characteristics for need for pelvic transarterial embolization (TAE) to determine the risk factors of false-positives. A retrospective study was performed in our trauma center between 2010 and 2015. All severe trauma patients with pelvic fracture were included. Pelvic ICE characteristics on computed tomography (CT) scan were studied: arterial (aSICE), portal surface (pSICE), and extension (exSICE) anatomic relationships. The overall predictive performance of ICE surfaces for pelvic TAE was analyzed using receiver operating characteristic curves. The analysis focused on risk factors for false-positives. Among 311 severe trauma patients with pelvic ring fracture (mean age, 42 ± 19 years, mean Injury Severity Score, 27 ± 19), 94 (30%) had at least one pelvic ICE on the initial CT scan. Patients requiring pelvic TAE had significantly larger aSICE and pSICE than others (P=0.001 and P=0.035, respectively). The overall ability of ICE surfaces to predict pelvic TAE was modest (aSICE AUC, 0.76 [95% CI, 0.64-0.90]; P=0.011) or non-significant (pSICE and exSICE). The high-sensitivity threshold was defined as aSICE ≥20 mm. Using this threshold, 76% of patients were false-positives. Risk factors for false-positives were: admission systolic blood pressure ≥90 mmHg (63% versus 20%; P=0.03) and low transfusion needs (63% versus 10%; P=0.009), extravasation in contact with complex bone fracture (78% versus 30%; P=0.008) or the absence of a direct relationship between extravasation and a large retroperitoneal hematoma (100% versus 38%; P<0.001). A significant pelvic ICE during the arterial phase does not guarantee the need for pelvic TAE. Three-quarter of patients with aSICE ≥20 mm did not need pelvic TAE. Several complementary CT scan criteria will help to identify this risk of false-positives to determine adequate hemostatic pelvic procedures.This work is an original article, retrospective study Level II of evidence, Therapeutic/Critical Care management.
2014-01-01
Background There has been an increase in natural disasters in recent years, which leads to a great number of injuries and deaths. It still remains an unsolved problem to treat patients with vascular injury of solid organs effectively following natural disasters, but on-spot emergency interventional transcatheter arterial embolization (TAE) has been highly recommended to cure serious vascular injury of solid organs nowadays. Spleen is the most vulnerable abdominal organ, severe arterial hemorrhage of which can cause death if untreated timely. In this research, we aimed to study the possibility of performing emergency surgical intervention in mobile minimally invasive interventional shelter for splenic injury in the case of natural disasters. Methods First, the mobile minimally invasive interventional shelter was unfolded in the field, and then disinfection and preoperative preparation were performed immediately. Eight large animal models of splenic injury were created, and angiograms were performed using a digital subtraction angiography machine in the mobile minimally invasive interventional shelter, and then the hemostatic embolizations of injured splenic artery were performed following the established convention of rapid intervention therapy. The operating time was recorded, and the survival condition and postoperative complications were observed for two weeks. Results and discussion The average time of unfolding the shelter, and performing disinfection and preoperative preparation was 33 ± 7 min. The number of colonies in the sterilized shelter body was 86 ± 13 cfu/m3. The average TAE time was 31 ± 7 min. All the hemostatic embolizations of splenic injury were performed successfully in the mobile minimally invasive interventional shelter during the operation. A pseudoaneurysm was found in an animal model using angiography two weeks after the operation. The primary clinical success rate of embolization was 87.5%. The two-week survival rate in all animal models of splenic injury was 100%. Conclusions Our findings in the current study demonstrate that the mobile minimally invasive interventional shelter can be adapted to the field perfectly and complete emergency surgical intervention for splenic injury efficiently and safely. Therefore, on-spot emergency interventional TAE for vascular injury of solid organs (e.g. spleen) in mobile minimally invasive interventional shelter is available and effective. PMID:25103472
Transcatheter Arterial Embolization for Bleeding Peptic Ulcers: A Multicenter Study.
Spiliopoulos, Stavros; Inchingolo, Riccardo; Lucatelli, Pierleone; Iezzi, Roberto; Diamantopoulos, Athanasios; Posa, Alessandro; Barry, Bryan; Ricci, Carmelo; Cini, Marco; Konstantos, Chrysostomos; Palialexis, Konstantinos; Reppas, Lazaros; Trikola, Artemis; Nardella, Michele; Adam, Andreas; Brountzos, Elias
2018-04-18
To investigate the outcomes of transcatheter arterial embolization (TAE) for the treatment of peptic ulcer bleeding (PUB). This is a retrospective, multicenter study, which investigated all patients who underwent TAE for the treatment of severe upper gastrointestinal hemorrhage from peptic ulcers in five European centers, between January 1, 2012 and May 1, 2017. All patients had undergone failed endoscopic hemostasis. Forty-four patients (male; mean age 74.0 ± 11.1 years, range 49-94), with bleeding from duodenum (36/44; 81.8%) or gastric ulcer (8/44; 18.2%) were followed up to 3.5 years (range 2-1354 days). In 42/44 cases, bleeding was confirmed by pre-procedural CT angiography. In 50% of the cases, coils were deployed, while in the remaining glue, microparticles, gel foam and combinations of the above were used. The study's outcome measures were 30-day survival technical success (occlusion of feeding vessel and/or no extravasation at completion DSA), overall survival, bleeding relapse and complication rates. The technical success was 100%. The 30-day survival rate was 79.5% (35/44 cases). No patients died due to ongoing or recurrent hemorrhage. Re-bleeding occurred in 2/44 cases (4.5%) and was successfully managed with repeat TAE (one) or surgery (one). The rate of major complications was 4.5% (2/44; one acute pancreatitis and one partial pancreatic ischemia), successfully managed conservatively. According to Kaplan-Meier analysis survival was 71.9% at 3.5 years. TAE for the treatment of PUB was technically successful in all cases and resulted in high clinical success rate. Minimal re-bleeding rates further highlight the utility of TAE as the second line treatment of choice, after failed endoscopy.
Abdulmalak, Gilles; Chevallier, Olivier; Falvo, Nicolas; Di Marco, Lucy; Bertaut, Aurélie; Moulin, Benjamin; Abi-Khalil, Célina; Gehin, Sophie; Charles, Pierre-Emmanuel; Latournerie, Marianne; Midulla, Marco; Loffroy, Romaric
2018-03-01
To assess the efficacy and the safety of Glubran ® 2 n-butyl cyanoacrylate metacryloxysulfolane (NBCA-MS) transcatheter arterial embolization (TAE) for acute arterial bleeding from varied anatomic sites and to evaluate the predictive factors associated with clinical success and 30-day mortality. A retrospective review of consecutive patients who underwent emergent NBCA-MS Glubran ® 2 TAE between July 2014 and August 2016 was conducted. Variables including age, sex, underlying malignancy, cardiovascular comorbidities, coagulation data, systolic blood pressure, and number of red blood cells units (RBC) transfused before TAE were collected. Clinical success, 30-day mortality, and complication rates were evaluated. Prognostic factors were evaluated by uni- and multivariate logistic regression analyses for clinical success, and by uni- and bivariate analyses after adjustment by bleeding sites for 30-day mortality. 104 patients underwent technically successful embolization with bleeding located in muscles (n = 34, 32.7%), digestive tract (n = 28, 26.9%), and viscera (n = 42, 40.4%). Clinical success rate was 76% (n = 79) and 30-day mortality rate was 21.2% (n = 22). Clinical failure was significantly associated with mortality (p < 0.0001). A number of RBC units transfused greater than or equal to 3 were associated with poorer clinical success (p = 0.025) and higher mortality (p = 0.03). Complications (n = 4, 3.8%) requiring surgery occurred only at puncture site. No ischemic complications requiring further invasive treatment occurred. Mean TAE treatment time was 4.55 min. NBCA-MS Glubran ® 2 TAE is a fast, effective, and safe treatment for acute arterial bleeding whatever the bleeding site.
Hsia, C C; Zurawska, J H; Tong, M Z Y; Eckert, K; McAlister, V C; Chin-Yee, I H
2009-02-01
The objective of this study was to determine if clinically important thromboembolic adverse events (TAEs) because of recombinant activated factor VII (rFVIIa) administration are being under-reported. rFVIIa is a potent haemostatic agent with a short half-life of 2.6 h that is increasingly used in 'off-label' situations. Retrospective review of 94 patients who received rFVIIa during 1 January 2003 to 30 June 2007 was carried out at a tertiary care centre. Sixty-nine patients, 32 females and 37 males, mean age 55 years (18-84 years), satisfied study criteria of off-label usage. This was a high-risk population with 33 (48%) deaths. A mean dose of 8.2 mg (2.4-19.2 mg) was administered in two average divided doses. Thirty-six potential TAEs were identified in 29 patients, and of these, 12 patients had TAEs deemed to be rFVIIa related and were identified on average 8.8 days after exposure to rFVIIa. Forty-eight (70%) physician questionnaires were completed; however, no TAEs were reported in these questionnaires or on chart review. Potential clinically significant TAEs are being under-reported by treating physicians. Until further evidence, we suggest the urgent need to develop consensus recommendations for utilization and required follow up to monitor the safety of rFVIIa and that at a minimum, all use of rFVIIa should be regulated through a gate-keeping mechanism that ensures adherence to these policies. Furthermore, prospective registries and trials are necessary to evaluate the efficacy and safety of rFVIIa in off-label settings.
Liu, Pan; Liu, Jie; Dong, Huixue; Sun, Jiaqiang
2018-02-01
Bread wheat (Triticum aestivum) spike architecture is an important agronomic trait. The Q gene plays a key role in the domestication of bread wheat spike architecture. However, the regulatory mechanisms of Q expression and transcriptional activity remain largely unknown. In this study, we show that overexpression of bread wheat tae-miR172 caused a speltoid-like spike phenotype, reminiscent of that in wheat plants with the q gene. The reduction in Q transcript levels in the tae-miR172 overexpression transgenic bread wheat lines suggests that the Q expression can be suppressed by tae-miR172 in bread wheat. Indeed, our RACE analyses confirmed that the Q mRNA is targeted by tae-miR172 for cleavage. According to our analyses, the Q protein is localized in nucleus and confers transcriptional repression activity. Meanwhile, the Q protein could physically interact with the bread wheat transcriptional co-repressor TOPLESS (TaTPL). Specifically, the N-terminal ethylene-responsive element binding factor-associated amphiphilic repression (EAR) (LDLNVE) motif but not the C-terminal EAR (LDLDLR) motif of Q protein mediates its interaction with the CTLH motif of TaTPL. Moreover, we show that the N-terminal EAR motif of Q protein is also essentially required for the transcriptional repression activity of Q protein. Taken together, we reveal the functional regulation of Q protein by tae-miR172 and transcriptional co-repressor TaTPL in controlling the bread wheat spike architecture. © 2017 The Authors. Plant Biotechnology Journal published by Society for Experimental Biology and The Association of Applied Biologists and John Wiley & Sons Ltd.
Iwamoto, Wataru; Okuno, Yuji; Matsumura, Noboru; Kaneko, Takao; Ikegami, Hiroyasu
2017-08-01
Abnormal vessels and accompanying nerves are possible sources of pain with lateral epicondylitis. The purpose of this study was to describe the safety and efficacy of transcatheter arterial embolization (TAE) for lateral epicondylitis resistant to conservative treatment. This prospective study was conducted in 24 patients with lateral epicondylitis resistant to conservative treatments for more than 3 months, with a symptom duration longer than 6 months, and with moderate to severe pain who were treated with TAE between March 2013 and October 2014. Two patients were lost to follow-up, and the remaining 22 patients were followed up for 2 years after TAE. Abnormal vessels were identified in all of the patients. No major adverse events were observed. The Quick Disabilities of the Arm, Shoulder and Hand scores at baseline significantly decreased at 1, 3, 6, and 24 months after treatment (50.8 vs 23.4, 8.3, 5.3, and 2.7, respectively; all P < .001). There was a statistically significant (P < .001) change from baseline to the last observed value in all of the clinical parameters, including visual analog scale pain score, Patient-Rated Tennis Elbow Evaluation score, and pain-free grip strength. Magnetic resonance images obtained 2 years after TAE showed an improvement in tendinosis and tear scores compared with baseline, and no patients showed bone marrow necrosis, obvious cartilage loss, or muscle atrophy. TAE could be one possible treatment option for patients with lateral epicondylitis that fails to improve with conservative treatments. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popov, Milen; Sotiriadis, Charalampos; Gay, Frederique
PurposeTo report our experience using a multilevel patient management algorithm to direct transarterial embolization (TAE) in managing spontaneous intramuscular hematoma (SIMH).Materials and MethodsFrom May 2006 to January 2014, twenty-seven patients with SIMH had been referred for TAE to our Radiology department. Clinical status and coagulation characteristics of the patients are analyzed. An algorithm integrating CT findings is suggested to manage SIMH. Patients were classified into three groups: Type I, SIMH with no active bleeding (AB); Type II, SIMH with AB and no muscular fascia rupture (MFR); and Type III, SIMH with MFR and AB. Type II is furthermore subcategorized asmore » IIa, IIb and IIc. Types IIb, IIc and III were considered for TAE. The method of embolization as well as the material been used are described. Continuous variables are presented as mean ± SD. Categorical variables are reported as percentages. Technical success, clinical success, complications and 30-day mortality (d30 M) were analyzed.ResultsTwo patients (7.5%) had Type IIb, four (15%) Type IIc and 21 (77.5%) presented Type III. The detailed CT and CTA findings, embolization procedure and materials used are described. Technical success was 96% with a complication rate of 4%. Clinical success was 88%. The bleeding-related thirty-day mortality was 15% (all with Type III).ConclusionTAE is a safe and efficient technique to control bleeding that should be considered in selected SIMH as soon as possible. The proposed algorithm integrating CT features provides a comprehensive chart to select patients for TAE.Level of Evidence4.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michimoto, Kenkichi, E-mail: michikoo@jikei.ac.jp; Shimizu, Kanichiro; Kameoka, Yoshihiko
PurposeTo retrospectively evaluate the feasibility of transcatheter arterial embolization (TAE) using a mixture of absolute ethanol and iodized oil to improve localization of endophytic renal masses on unenhanced computed tomography (CT) prior to CT-guided percutaneous cryoablation (PCA).Materials and MethodsOur institutional review board approved this retrospective study. From September 2011 to June 2015, 17 patients (mean age, 66.8 years) with stage T1a endophytic renal masses (mean diameter, 26.5 mm) underwent TAE using a mixture of absolute ethanol and iodized oil to improve visualization of small and endophytic renal masses on unenhanced CT prior to CT-guided PCA. TAE was considered successful that accumulated iodizedmore » oil depicted whole of the tumor edge on CT. PCA was considered successful when the iceball covered the entire tumor with over a 5 mm margin. Oncological and renal functional outcomes and complications were also evaluated.ResultsTAE was successfully performed in 16 of 17 endophytic tumors. The 16 tumors were performed under CT-guided PCA with their distinct visualization of localization and safe ablated margin. During the mean follow-up period of 15.4 ± 5.1 months, one patient developed local recurrence. Estimated glomerular filtration rate declined by 8 % with statistical significance (P = 0.01). There was no procedure-related significant complication.ConclusionTAE using a mixture of absolute ethanol and iodized oil to improve visualization of endophytic renal masses facilitated tumor localization on unenhanced CT, permitting depiction of the tumor edge as well as a safe margin for ablation during CT-guided PCA, with an acceptable decline in renal function.« less
An Embedded Rule-Based Diagnostic Expert System in Ada
NASA Technical Reports Server (NTRS)
Jones, Robert E.; Liberman, Eugene M.
1992-01-01
Ada is becoming an increasingly popular programming language for large Government-funded software projects. Ada with it portability, transportability, and maintainability lends itself well to today's complex programming environment. In addition, expert systems have also assumed a growing role in providing human-like reasoning capability expertise for computer systems. The integration is discussed of expert system technology with Ada programming language, especially a rule-based expert system using an ART-Ada (Automated Reasoning Tool for Ada) system shell. NASA Lewis was chosen as a beta test site for ART-Ada. The test was conducted by implementing the existing Autonomous Power EXpert System (APEX), a Lisp-based power expert system, in ART-Ada. Three components, the rule-based expert systems, a graphics user interface, and communications software make up SMART-Ada (Systems fault Management with ART-Ada). The rules were written in the ART-Ada development environment and converted to Ada source code. The graphics interface was developed with the Transportable Application Environment (TAE) Plus, which generates Ada source code to control graphics images. SMART-Ada communicates with a remote host to obtain either simulated or real data. The Ada source code generated with ART-Ada, TAE Plus, and communications code was incorporated into an Ada expert system that reads the data from a power distribution test bed, applies the rule to determine a fault, if one exists, and graphically displays it on the screen. The main objective, to conduct a beta test on the ART-Ada rule-based expert system shell, was achieved. The system is operational. New Ada tools will assist in future successful projects. ART-Ada is one such tool and is a viable alternative to the straight Ada code when an application requires a rule-based or knowledge-based approach.
Modeling TAE Response To Nonlinear Drives
NASA Astrophysics Data System (ADS)
Zhang, Bo; Berk, Herbert; Breizman, Boris; Zheng, Linjin
2012-10-01
Experiment has detected the Toroidal Alfven Eigenmodes (TAE) with signals at twice the eigenfrequency.These harmonic modes arise from the second order perturbation in amplitude of the MHD equation for the linear modes that are driven the energetic particle free energy. The structure of TAE in realistic geometry can be calculated by generalizing the linear numerical solver (AEGIS package). We have have inserted all the nonlinear MHD source terms, where are quadratic in the linear amplitudes, into AEGIS code. We then invert the linear MHD equation at the second harmonic frequency. The ratio of amplitudes of the first and second harmonic terms are used to determine the internal field amplitude. The spatial structure of energy and density distribution are investigated. The results can be directly employed to compare with experiments and determine the Alfven wave amplitude in the plasma region.
Ultra-Dense Quantum Communication Using Integrated Photonic Architecture
2012-02-03
and tae have the same right singular vectors , and their singular-value decompositions can be written as tab = uabsabv †, (30) tae = uaesaev †, (31...freedom such as polarization or spatial modes), making its implementation ideal for fiber optics networks. (iii) The protocol promises unprecedented...well as temporal correlations. In particular, using 8 wavelength channels for an additional 3 bpp and two polarization states for one additional bpp
1985-08-19
SOUTH KOREA POLITICS AND GOVERNMENT NKDP Post-Election Tasks, Problems Scrutinized (HANGUK ILBO, 17 Feb 85) • 63 67 Kim Tae-chung, Kim Yong -sam...National Day 122 Kim Il-song Sends Greetings 123 Kim Yong -nam Greets Maldives Counterpart 123 Kim Il-song Greets Peru President on National Day (KCNA, 27...including Kim Tae- yong , member of the Subcommittee for the Masses of the Sammin Struggle Committee of the Seoul National University [SNU], Ha Tong
Self-Consistent Frequency Sweeping of TAE mode
NASA Astrophysics Data System (ADS)
Wang, Ge
2012-03-01
We have extended our intuitive Toroidal Alfven Wave (TAE) model [1] for describing spontaneous frequency sweeping by a destabilizing component of energetic particles. Now a fully developed self-consistent description for frequency sweeping of an isolated TAE mode has been developed. As in [1], we use the Rosenbluth, Berk,Van Dam tip theory [2], valid for low beta, large aspect ratio, circular tokamaks, to describe the evolution of the TAE wave equation. The wave is coupled to the particle dynamics that uses the Berk, Breizman, Ye map model [3] to construct the particle/wave Lagrangian associated with a phase space dependent mode structure. Then together with the appropriate Vlasov equation for describing the particle dynamics, a set of equations determining the dynamics of the system has been formulated. Adiabatic solutions have been obtained and work is underway in simulating the exact nonlinear dynamics. A status report of our results will be given at the meeting. [4pt] [1] G. Wang and H. L. Berk, Communication in Nonlinear Science and Numerical Simulation 17, 2179 (2012) [0pt] [2] M. N. Rosenbluth,; H. L. Berk, J. Van Dam and D. M. Lingberg, Phys. Rev. Lett. 68, 596 (1992). [0pt] [3] Berk, H.L.; Breizman, B.N.; Ye, H. In: Physics of Fluids B 51993, 1506 (1993)
JPRS Report, East Asia, Korea: KULLOJA, No. 2, February 1990
1990-10-19
translated.] Editorial On Eradication of Bureaucratism [ Kim Il-song] 1 Political and Ideological Let Us Give Full Play to the Revolutionary Spirit...Radical Turn in Mass Guidance—On the 30th Anniversary of the founding of the Chongsan-ri Spirit, Chongsan-ri Method [Kye Ung -tae; not translated...Structures of the WPK Era [ Kim Tae-ho; not translated] 7 Enhancement of Indoctrination in Class Character Is an Important Requirement for
Alpha-Driven MHD and MHD-Induced Alpha Loss in TFTR DT Experiments
NASA Astrophysics Data System (ADS)
Chang, Zuoyang
1996-11-01
Theoretical calculation and numerical simulation indicate that there can be interesting interactions between alpha particles and MHD activity which can adversely affect the performance of a tokamak reactor (e.g., ITER). These interactions include alpha-driven MHD, like the toroidicity-induced-Alfven-eigenmode (TAE) and MHD induced alpha particle losses or redistribution. Both phenomena have been observed in recent TFTR DT experiments. Weak alpha-driven TAE activity was observed in a NBI-heated DT experiment characterized by high q0 ( >= 2) and low core magnetic shear. The TAE mode appears at ~30-100 ms after the neutral beam turning off approximately as predicted by theory. The mode has an amplitude measured by magnetic coils at the edge tildeB_p ~1 mG, frequency ~150-190 kHz and toroidal mode number ~2-3. It lasts only ~ 30-70 ms and has been seen only in DT discharges with fusion power level about 1.5-2.0 MW. Numerical calculation using NOVA-K code shows that this type of plasma has a big TAE gap. The calculated TAE frequency and mode number are close to the observation. (2) KBM-induced alpha particle loss^1. In some high-β, high fusion power DT experiments, enhanced alpha particle losses were observed to be correlated to the high frequency MHD modes with f ~100-200 kHz (the TAE frequency would be two-times higher) and n ~5-10. These modes are localized around the peak plasma pressure gradient and have ballooning characteristics. Alpha loss increases by 30-100% during the modes. Particle orbit simulations show the added loss results from wave-particle resonance. Linear instability analysis indicates that the plasma is unstable to the kinetic MHD ballooning modes (KBM) driven primarily by strong local pressure gradients. ----------------- ^1Z. Chang, et al, Phys. Rev. Lett. 76 (1996) 1071. In collaberation with R. Nazikian, G.-Y. Fu, S. Batha, R. Budny, L. Chen, D. Darrow, E. Fredrickson, R. Majeski, D. Mansfield, K. McGuire, G. Rewoldt, G. Taylor, R. White, K.-L. Wong and S. Zweben, Princeton Plasma Physics Lab. Department of Physics, University of California, Irvine, CA 92717 ^*Work supported by the U.S. Department of Energy DoE Contract No. DE-AC02-76CH03073.
Rapid Frequency Chirps of TAE mode due to Finite Orbit Energetic Particles
NASA Astrophysics Data System (ADS)
Berk, Herb; Wang, Ge
2013-10-01
The tip model for the TAE mode in the large aspect ratio limit, conceived by Rosenbluth et al. in the frequency domain, together with an interaction term in the frequency domain based on a map model, has been extended into the time domain. We present the formal basis for the model, starting with the Lagrangian for the particle wave interaction. We shall discuss the formal nonlinear time domain problem and the procedure that needs to obtain solutions in the adiabatic limit.
Translations on North Korea. Number 616.
1978-09-20
Chin-u, Kye Ung -tae, Kim -hwan, Kim Man-kum, Ho Tam, Chong Chun-ki and Kong Chin-tae. Attending the soiree were Comrade Han Tok-su, chairman of the...Committee which was held on 10 June under the leadership of Kim Il-song; listed ninth, after Kim Tu- yong and before No T’ae-sok (NODONG SINMUN 12 Jun...Province KWP Committee which was held on 10 June under the leadership of Kim Il-song; listed seventh, after Kang Song-san and before Kim Tu- yong
Zhou, Jian-yong; Zhang, Xiao-yue; Yu, Mei-ling; Lu, Sheng-feng; Chen, Xia
2016-02-01
To observe the effect of transcutaneuos acupoint electrostimulation(TAES) on ovarian serum sex hormone levels and ovarian follicle granular cell aromatase cytochrome P 450 (P 450 arom) protein and follicle theca cell cytochrome P 450 17 α-hydroxylase/c 17-20 lyase cytochrome P 450 (P 450 c 17 α) protein expression in polycystic ovary syndrome (PCOS)rats, so as to explore its mechanisms underlying improvement of PCOS. METHODS Forty SD rats were randomly divided into four groups: normal control, model, medication and TAES (10 rats/group). The PCOS model was established by giving (gavage) the animals with letrozole solution (1.0 mg/kg, once daily for 21 consecutive days). Rats of the medication group were treated with Clomiphene (1 mg/kg) once daily for 7 days, and those of the TAES group were treated with electrical stimulation (2 Hz, 3 mA) of "Guanyuan" (CV 4) and "Sanyinjiao" (SP 6) areas for 30 min, once daily for 7 consecutive days. The rats body weight and bilateral ovarian weight were detected, and the ovarian structure and follicular development degree were observed under light microscope after H. E. stain, and the serum testosterone (T), estradiol (E2), luteotrophic hormone (LH) and follicle-stimulating hormone (FSH) contents were detected using radioimmunoassay. The expression of ovarian P 450 arom (for production of estrogen)protein and P 450 c 17 α (for production of androgen) protein was detected by using immunohistochemical stain and Western blot, respectively. The body weight, bilateral ovary weight, serum T and LH contents, and ratio of LH/FSH, and ovarian P 450 c 17 α immunoactivity and protein expression levels in the model group were all significantly increased compared with the normal control group (P < 0.01), and the levels of serum E2 and ovarian P 450 arom immunoactivity and protein expression were significantly decreased after modeling (P < 0.01). Following the treatment, the increased body weight, ovary weight, serum T and LH contents, ratio of LH/FSH, and ovarian P 450 c 17 α immunoactivity and protein expression levels, and the decreased ovarian P 450 arom immunoactivity and protein expression levels were reversed in the TAES group (P < 0.01, P < 0.05) rather than in the medication group, except serum T and ratio of LH/FSH in the medication group. No significant differences were found between the medication and TAES groups in the serum T and ratio of LH/FSH (P > 0.05). In addition, the increased vesicular follicle number, the decreased corepus luteum number and the thickness of granular cell layer were markedly improved in the TAES group. TAES intervention can reduce both body weight and ovarian weight and regulate the levels of serum sex hormones and ovarian P 450 c 17 α and P 450 arom protein expression levels in PCOS rats, which may contribute to its effect in improving PCOS.
A design for a new catalog manager and associated file management for the Land Analysis System (LAS)
NASA Technical Reports Server (NTRS)
Greenhagen, Cheryl
1986-01-01
Due to the larger number of different types of files used in an image processing system, a mechanism for file management beyond the bounds of typical operating systems is necessary. The Transportable Applications Executive (TAE) Catalog Manager was written to meet this need. Land Analysis System (LAS) users at the EROS Data Center (EDC) encountered some problems in using the TAE catalog manager, including catalog corruption, networking difficulties, and lack of a reliable tape storage and retrieval capability. These problems, coupled with the complexity of the TAE catalog manager, led to the decision to design a new file management system for LAS, tailored to the needs of the EDC user community. This design effort, which addressed catalog management, label services, associated data management, and enhancements to LAS applications, is described. The new file management design will provide many benefits including improved system integration, increased flexibility, enhanced reliability, enhanced portability, improved performance, and improved maintainability.
SOT: A rapid prototype using TAE windows
NASA Technical Reports Server (NTRS)
Stephens, Mark; Eike, David; Harris, Elfrieda; Miller, Dana
1986-01-01
The development of the window interface extension feature of the Transportable Applications Executive (TAE) is discussed. This feature is being used to prototype a space station payload interface in order to demonstrate and assess the benefits of using windows on a bit mapped display and also to convey the concept of telescience, the control and operation of space station payloads from remote sites. The prototype version of the TAE with windows operates on a DEC VAXstation 100. This workstation has a high resolution 19 inch bit mapped display, a keyboard and a three-button mouse. The VAXstation 100 is not a stand-alone workstation, but is controlled by software executing on a VAX/8600. A short scenario was developed utilizing the Solar Optical Telescope (SOT) as an example payload. In the scenario the end-user station includes the VAXstation 100 plus an image analysis terminal used to display the CCD images. The layout and use of the prototype elements, i.e., the root menu, payload status window, and target acquisition menu is described.
Saturation of a toroidal Alfvén eigenmode due to enhanced damping of nonlinear sidebands
NASA Astrophysics Data System (ADS)
Todo, Y.; Berk, H. L.; Breizman, B. N.
2012-09-01
This paper examines nonlinear magneto-hydrodynamic effects on the energetic particle driven toroidal Alfvén eigenmode (TAE) for lower dissipation coefficients and with higher numerical resolution than in the previous simulations (Todo et al 2010 Nucl. Fusion 50 084016). The investigation is focused on a TAE mode with toroidal mode number n = 4. It is demonstrated that the mechanism of mode saturation involves generation of zonal (n = 0) and higher-n (n ⩾ 8) sidebands, and that the sidebands effectively increase the mode damping rate via continuum damping. The n = 0 sideband includes the zonal flow peaks at the TAE gap locations. It is also found that the n = 0 poloidal flow represents a balance between the nonlinear driving force from the n = 4 components and the equilibrium plasma response to the n = 0 fluctuations. The spatial profile of the n = 8 sideband peaks at the n = 8 Alfvén continuum, indicating enhanced dissipation due to continuum damping.
Alfvén eigenmode evolution computed with the VENUS and KINX codes for the ITER baseline scenario
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isaev, M. Yu., E-mail: isaev-my@nrcki.ru; Medvedev, S. Yu.; Cooper, W. A.
A new application of the VENUS code is described, which computes alpha particle orbits in the perturbed electromagnetic fields and its resonant interaction with the toroidal Alfvén eigenmodes (TAEs) for the ITER device. The ITER baseline scenario with Q = 10 and the plasma toroidal current of 15 MA is considered as the most important and relevant for the International Tokamak Physics Activity group on energetic particles (ITPA-EP). For this scenario, typical unstable TAE-modes with the toroidal index n = 20 have been predicted that are localized in the plasma core near the surface with safety factor q = 1.more » The spatial structure of ballooning and antiballooning modes has been computed with the ideal MHD code KINX. The linear growth rates and the saturation levels taking into account the damping effects and the different mode frequencies have been calculated with the VENUS code for both ballooning and antiballooning TAE-modes.« less
Properties of Alfven Eigenmodes in the TAE range on the National Spherical Torus Experiment-Upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2013-04-24
A second Neutral Beam (NB) injection line is being installed on the NSTX Upgrade device, resulting in six NB sources with di erent tangency radii that will be available for heating and current drive. This work explores the properties of instabilities in the frequency range of the Toroidal Alfv en Eigenmode (TAE) for NSTX-U scenarios with various NB injection geometries, from more perpendicular to more tangential, and with increased toroidal magnetic eld with respect to previous NSTX scenarios. Predictions are based on analysis through the ideal MHD code NOVA-K. For the scenarios considered in this work, modi cations of themore » Alfv en continuum result in a frequency upshift and a broadening of the radial mode structure. The latter e ect may have consequences for fast ion transport and loss. Preliminary stability considerations indicate that TAEs are potentially unstable, with ion Landau damping representing the dominant damping mechanism« less
NASA Astrophysics Data System (ADS)
Ogawa, Kunihiro; Isobe, Mitsutaka; Toi, Kazuo; Shimizu, Akihiro; Spong, Donald A.; Osakabe, Masaki; Yamamoto, Satoshi; the LHD Experiment Group
2014-09-01
Experiments to reveal energetic ion dynamics associated with magnetohydrodynamic activity are ongoing in the Large Helical Device (LHD). Interactions between beam-driven toroidal Alfvén eigenmodes (TAEs) and energetic ions have been investigated. Energetic ion losses induced by beam-driven burst TAEs have been observed using a scintillator-based lost fast-ion probe (SLIP) in neutral beam-heated high β plasmas. The loss flux of co-going beam ions increases as the TAE amplitude increases. In addition to this, the expulsion of beam ions associated with edge-localized modes (ELMs) has been also recognized in LHD. The SLIP has indicated that beam ions having co-going and barely co-going orbits are affected by ELMs. The relation between ELM amplitude and ELM-induced loss has a dispersed structure. To understand the energetic ion loss process, a numerical simulation based on an orbit-following model, DELTA5D, that incorporates magnetic fluctuations is performed. The calculation result shows that energetic ions confined in the interior region are lost due to TAE instability, with a diffusive process characterizing their loss. For the ELM, energetic ions existing near the confinement/loss boundary are lost through a convective process. We found that the ELM-induced loss flux measured by SLIP changes with the ELM phase. This relation between the ELM amplitude and measured ELM-induced loss results in a more dispersed loss structure.
Free-boundary toroidal Alfvén eigenmodes
NASA Astrophysics Data System (ADS)
Chen, Eugene Y.; Berk, H. L.; Breizman, B.; Zheng, L. J.
2011-05-01
A numerical study is presented for the n = 1 free-boundary toroidal Alfvén eigenmodes (TAE) in tokamaks, which shows that there is considerable sensitivity of n = 1 modes to the position of the conducting wall. An additional branch of the TAE is shown to emerge from the upper continuum as the ratio of conducting wall radius to plasma radius increases. Such phenomena arise in plasma equilibria with both circular and shaped cross sections, where the shaped profile studied here is similar to that found in Alcator C-Mod.
Injuries in martial arts: a comparison of five styles.
Zetaruk, M N; Violán, M A; Zurakowski, D; Micheli, L J
2005-01-01
To compare five martial arts with respect to injury outcomes. A one year retrospective cohort was studied using an injury survey. Data on 263 martial arts participants (Shotokan karate, n = 114; aikido, n = 47; tae kwon do, n = 49; kung fu, n = 39; tai chi, n = 14) were analysed. Predictor variables included age, sex, training frequency (
Takeda, Akihiro; Koike, Wataru
2017-12-01
To report our experience on the value of transcatheter arterial embolization (TAE) or transcatheter arterial chemoembolization (TACE) for the uterus-preserving management of retained placenta accreta with marked vascularity after abortion or delivery. Thirty-eight consecutive women with retained placenta accreta were retrospectively analyzed over a 5-year period. When elevated levels of serum β-hCG (> 25 mIU/mL) were detected, TACE with dactinomycin was chosen for devascularization along with cytotoxic effects on active trophoblasts; in contrast, if the serum β-hCG level was low (≤ 25 mIU/mL), TAE was chosen. After confirming devascularization, the additional need for hysteroscopic resection and systemic methotrexate administration was individually determined. The most frequent sign and symptom in the abortion group was significant hemorrhaging, while a hypervascular mass detected at a regular check-up was the most frequent in the delivery group. The median time elapsed between abortion and endovascular management was 36 days, and the median time elapsed after delivery was 31.5 days. TACE was performed more frequently than TAE in the abortion group, while TAE was the more frequent procedure in the delivery group. In 10 and 11 cases, after abortion and delivery, respectively, hysteroscopic resection was performed. Systemic methotrexate administration was additionally done in three and one cases after abortion and delivery, respectively. Uterine preservation was achieved in all cases. This case series emphasizes that endovascular embolization is an effective key intervention with or without additional therapies for uterus-preserving management of retained placenta accreta with marked vascularity after abortion or delivery.
Okuno, Yuji; Iwamoto, Wataru; Matsumura, Noboru; Oguro, Sota; Yasumoto, Taku; Kaneko, Takao; Ikegami, Hiroyasu
2017-02-01
To evaluate clinical outcomes of transcatheter arterial embolization (TAE) for adhesive capsulitis resistant to conservative treatments. This study comprised 25 patients (18 women and 7 men; mean age, 53.8 y; range, 39-68 y) with adhesive capsulitis resistant to conservative treatments. TAE was performed, and adverse events (AEs), pain visual analog scale (VAS) score changes, range of motion (ROM), and American Shoulder and Elbow Surgeons (ASES) scores were assessed. Abnormal vessels were identified in all patients. No major AEs were associated with TAE. One patient was lost to follow-up. The remaining 24 patients were available for final follow-up (mean, 36.1 months; range, 30-44 months). Of the 24 patients, 16 (67%) experienced quick improvement of nighttime pain (ie, VAS scores decreased > 50% from baseline) within 1 week, and 21 (87%) improved within 1 month. In terms of mean overall pain (ie, pain at its worst), VAS scores significantly decreased at 1, 3, and 6 months after treatment (82 mm before treatment vs 52, 19, and 8 mm after treatment; P < .001). ASES scores significantly improved at 1, 3, and 6 months after treatment (16.1 before treatment vs 41.4, 69.1, and 83.5 after treatment; P < .001). No symptom recurrence or late-onset AEs were observed. Shoulder ROM and function further improved during midterm follow-up. TAE is a possible treatment option for patients with adhesive capsulitis that has failed to improve with conservative treatments. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Varela, Jacobo Rodriguez; Spong, D. A.; Garcia, L.
2017-03-06
Here, energetic particle populations in nuclear fusion experiments can destabilize the Alfvén Eigenmodes through inverse Landau damping and couplings with gap modes in the shear Alfvén continua. We use the reduced MHD equations to describe the linear evolution of the poloidal flux and the toroidal component of the vorticity in a full 3D system, coupled with equations of density and parallel velocity moments for the energetic particles. We add the Landau damping and resonant destabilization effects using a closure relation. We apply the model to study the Alfvén mode stability in the inward-shifted configurations of the Large Helical Device (LHD), performing a parametric analysis of the energetic particle β (more » $${{\\beta}_{f}}$$ ) in a range of realistic values, the ratios of the energetic particle thermal/Alfvén velocities ($${{V}_{\\text{th}}}/{{V}_{A0}}$$ ), the magnetic Lundquist numbers (S) and the toroidal modes (n). The n = 1 and n = 2 TAEs are destabilized, although the n = 3 and n = 4 TAEs are weakly perturbed. The most unstable configurations are associated with the density gradients of energetic particles in the plasma core: the TAEs are destabilized, even for small energetic particle populations, if their thermal velocity is lower than 0.4 times the Alfvén velocity. The frequency range of MHD bursts measured in the LHD are 50–70 kHz for the n = 1 and 60–80 kHz for the n = 2 TAE, which is consistent with the model predictions.« less
Research observation: Hydrolyzable and condensed tannins in plants of northwest Spain forests
Gonzalez-Hernandez, M. P.; Karchesy, J.; Starkey, E.E.
2003-01-01
Tannins are secondary metabolites that may influence feeding by mammals on plants. We analyzed hydrolyzable and condensed tannins in 30 plant species consumed by livestock and deer, as a preliminary attempt to study their possible implications on browsing and grazing in forest ecosystems. Heathers (Ericaceae) and plants of the Rose (Rosaceae) family had tannins, while forbs, grasses and shrubs other than the heathers did not show astringency properties. We found the highest tannin content of all the species in Rubus sp., with the highest value around 180 mg TAE/g dry weight in spring. Potentilla erecta, Alnus glutinosa and Quercus robur were next with 57 to 44 mg TAE/g dw. Total tannins in heathers ranged from 22 to 36 mg TAE/g dw. Levels of condensed tannins were higher than hydrolyzable for most of the species. Only Betula alba, Calluna vulgaris, Pteridium aquilinum and Vaccinium myrtillus had 100% hydrolyzable tannins. Tannin content of the species changed seasonally with highest values during the growing season, corresponding to late winter or early spring, depending on the species.
Research observation: Hydrolyzable and condensed tannins in plants of the northwest
Gonzalez-Hernandez, M. P.; Karchesy, J.; Starkey, Edward E.
2003-01-01
Tannins are secondary metabolites that may influence feeding by mammals on plants. We analyzed hydrolyzable and condensed tannins in 30 plant species consumed by livestock and deer, as a preliminary attempt to study their possible implications on browsing and grazing in forest ecosystems. Heathers (Ericaceae) and plants of the Rose (Rosaceae) family had tannins, while forbs, grasses and shrubs other than the heathers did not show astringency properties. We found the highest tannin content of all the species in Rubus sp., with the highest value around 180 mg TAE/g dry weight in spring. Potentilla erecta, Alnus glutinosa and Quercus robur were next with 57 to 44 mg TAE/g dw. Total tannins in heathers ranged from 22 to 36 mg TAE/g dw. Levels of condensed tannins were higher than hydrolyzable for most of the species. Only Betula alba, Calluna vulgaris, Pteridium aquilinum and Vaccinium myrtillus had 100% hydrolyzable tannins. Tannin content of the species changed seasonally with highest values during the growing season, corresponding to late winter or early spring, depending on the species.
Simulation and theory of spontaneous TAE frequency sweeping
NASA Astrophysics Data System (ADS)
Wang, Ge; Berk, H. L.
2012-09-01
A simulation model, based on the linear tip model of Rosenbluth, Berk and Van Dam (RBV), is developed to study frequency sweeping of toroidal Alfvén eigenmodes (TAEs). The time response of the background wave in the RBV model is given by a Volterra integral equation. This model captures the properties of TAE waves both in the gap and in the continuum. The simulation shows that phase space structures form spontaneously at frequencies close to the linearly predicted frequency, due to resonant particle-wave interactions and background dissipation. The frequency sweeping signals are found to chirp towards the upper and lower continua. However, the chirping signals penetrate only the lower continuum, whereupon the frequency chirps and mode amplitude increases in synchronism to produce an explosive solution. An adiabatic theory describing the evolution of a chirping signal is developed which replicates the chirping dynamics of the simulation in the lower continuum. This theory predicts that a decaying chirping signal will terminate at the upper continuum though in the numerical simulation the hole disintegrates before the upper continuum is reached.
Measurements and modelling of fast-ion redistribution due to resonant MHD instabilities in MAST
NASA Astrophysics Data System (ADS)
Jones, O. M.; Cecconello, M.; McClements, K. G.; Klimek, I.; Akers, R. J.; Boeglin, W. U.; Keeling, D. L.; Meakins, A. J.; Perez, R. V.; Sharapov, S. E.; Turnyanskiy, M.; the MAST Team
2015-12-01
The results of a comprehensive investigation into the effects of toroidicity-induced Alfvén eigenmodes (TAE) and energetic particle modes on the NBI-generated fast-ion population in MAST plasmas are reported. Fast-ion redistribution due to frequency-chirping TAE in the range 50 kHz-100 kHz and frequency-chirping energetic particle modes known as fishbones in the range 20 kHz-50 kHz, is observed. TAE and fishbones are also observed to cause losses of fast ions from the plasma. The spatial and temporal evolution of the fast-ion distribution is determined using a fission chamber, a radially-scanning collimated neutron flux monitor, a fast-ion deuterium alpha spectrometer and a charged fusion product detector. Modelling using the global transport analysis code Transp, with ad hoc anomalous diffusion and fishbone loss models introduced, reproduces the coarsest features of the affected fast-ion distribution in the presence of energetic particle-driven modes. The spectrally and spatially resolved measurements show, however, that these models do not fully capture the effects of chirping modes on the fast-ion distribution.
Apple peel bioactive rich extracts effectively inhibit in vitro human LDL cholesterol oxidation.
Thilakarathna, Surangi H; Rupasinghe, H P Vasantha; Needs, Paul W
2013-05-01
Apple peels are rich in antioxidant bioactives and hence can possess the ability to inhibit human low density lipoprotein cholesterol (LDL-C) oxidation. LDL-C oxidation is known to initiate atherosclerotic plaque formation. Unique quercetin-rich (QAE) and triterpene-rich (TAE) apple peel extracts, their constituent compounds and three in vivo quercetin metabolites were investigated for in vitro LDL-C oxidation inhibition. Both extracts effectively inhibited Cu(2+)-induced LDL-C oxidation. IC(50) of QAE and TAE for LDL-C oxidation products were 0.06-8.29 mg/L and 29.58-95.49 mg/L, respectively. Quercetin compounds, chlorogenic acid and phloridzin could contribute more to the effectiveness of QAE at physiological concentrations. The three in vivo quercetin metabolites; quercetin-3'-sulfate, quercetin-3-glucuronic acid and isorhamnetin-3-glucuronic acid were effective at physiological concentrations and therefore, QAE can be effective in LDL-C oxidation inhibition under physiological conditions. Constituent TAE compounds did not perform well under Cu(2+)-induction. Overall, both extracts effectively inhibited LDL-C oxidation in vitro. Copyright © 2012 Elsevier Ltd. All rights reserved.
Korean women's attitudes toward pregnancy and prenatal care.
Pritham, U A; Sammons, L N
1993-01-01
A convenience sample of 40 native-born pregnant Korean women receiving prenatal care at a U.S. military facility in a major metropolitan area in Korea completed a questionnaire about attitudes toward pregnancy and prenatal care. Responses revealed a family life characterized by positive maternal and paternal perceptions of the pregnancy and less preference for a male child than we had anticipated. Traditional beliefs in Tae Mong, a conception dream, and Tae Kyo, rituals for safe childbirth, were followed. Food taboos, including protein sources, were reported. Attitudes toward prenatal care services, care providers, and maternal health habits are described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darrow, Douglas
Brief "avalanches" of toroidal Alfven eigenmodes (TAEs) are observed in NSTX plasmas with several different n numbers simultaneously present. These affect the neutral beam ion distribution as evidenced by a concurrent drop in the neutron rate and, sometimes, beam ion loss. Guiding center orbit modeling has shown that the modes can transiently render portions of the beam ion phase space stochastic. The resulting redistribution of beam ions can also create a broader beam-driven current profile and produce other changes in the beam ion distribution function
Program For Generating Interactive Displays
NASA Technical Reports Server (NTRS)
Costenbader, Jay; Moleski, Walt; Szczur, Martha; Howell, David; Engelberg, Norm; Li, Tin P.; Misra, Dharitri; Miller, Philip; Neve, Leif; Wolf, Karl;
1991-01-01
Sun/Unix version of Transportable Applications Environment Plus (TAE+) computer program provides integrated, portable software environment for developing and running interactive window, text, and graphical-object-based application software systems. Enables programmer or nonprogrammer to construct easily custom software interface between user and application program and to move resulting interface program and its application program to different computers. Plus viewed as productivity tool for application developers and application end users, who benefit from resultant consistent and well-designed user interface sheltering them from intricacies of computer. Available in form suitable for following six different groups of computers: DEC VAX station and other VMS VAX computers, Macintosh II computers running AUX, Apollo Domain Series 3000, DEC VAX and reduced-instruction-set-computer workstations running Ultrix, Sun 3- and 4-series workstations running Sun OS and IBM RT/PC and PS/2 compute
Another Program For Generating Interactive Graphics
NASA Technical Reports Server (NTRS)
Costenbader, Jay; Moleski, Walt; Szczur, Martha; Howell, David; Engelberg, Norm; Li, Tin P.; Misra, Dharitri; Miller, Philip; Neve, Leif; Wolf, Karl;
1991-01-01
VAX/Ultrix version of Transportable Applications Environment Plus (TAE+) computer program provides integrated, portable software environment for developing and running interactive window, text, and graphical-object-based application software systems. Enables programmer or nonprogrammer to construct easily custom software interface between user and application program and to move resulting interface program and its application program to different computers. When used throughout company for wide range of applications, makes both application program and computer seem transparent, with noticeable improvements in learning curve. Available in form suitable for following six different groups of computers: DEC VAX station and other VMS VAX computers, Macintosh II computers running AUX, Apollo Domain Series 3000, DEC VAX and reduced-instruction-set-computer workstations running Ultrix, Sun 3- and 4-series workstations running Sun OS and IBM RT/PC's and PS/2 computers running AIX, and HP 9000 S
NASA Astrophysics Data System (ADS)
Varela, J.; Spong, D. A.; Garcia, L.
2017-04-01
Energetic particle populations in nuclear fusion experiments can destabilize the Alfvén Eigenmodes through inverse Landau damping and couplings with gap modes in the shear Alfvén continua. We use the reduced MHD equations to describe the linear evolution of the poloidal flux and the toroidal component of the vorticity in a full 3D system, coupled with equations of density and parallel velocity moments for the energetic particles. We add the Landau damping and resonant destabilization effects using a closure relation. We apply the model to study the Alfvén mode stability in the inward-shifted configurations of the Large Helical Device (LHD), performing a parametric analysis of the energetic particle β ({βf} ) in a range of realistic values, the ratios of the energetic particle thermal/Alfvén velocities ({{V}\\text{th}}/{{V}A0} ), the magnetic Lundquist numbers (S) and the toroidal modes (n). The n = 1 and n = 2 TAEs are destabilized, although the n = 3 and n = 4 TAEs are weakly perturbed. The most unstable configurations are associated with the density gradients of energetic particles in the plasma core: the TAEs are destabilized, even for small energetic particle populations, if their thermal velocity is lower than 0.4 times the Alfvén velocity. The frequency range of MHD bursts measured in the LHD are 50-70 kHz for the n = 1 and 60-80 kHz for the n = 2 TAE, which is consistent with the model predictions. ).
Shima, Toshihide; Mizuno, Masayuki; Otsuji, Hideaki; Mizuno, Chiemi; Obata, Hirozumi; Park, Hyohun; Nakajo, Shinobu; Okanoue, Takeshi
2005-09-01
The aim of this study was to assess and compare the sensitivity of power Doppler sonography, contrast-enhanced sonography, plain computed tomography (CT), and dynamic magnetic resonance imaging (MRI) for detecting hepatocellular carcinoma (HCC) nodules incompletely treated with transcatheter arterial embolization (TAE). A total of 63 unresectable HCC nodules were examined in this study. The HCCs were treated with TAE. All patients underwent plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI 1 week after TAE. The sensitivity of each modality to incompletely treated HCC nodules was compared. Detection of the residual viable HCC on angiography or tumor biopsy was regarded as the gold standard for the diagnosis of incomplete treatment. Twenty-four nodules (38%) were diagnosed as incompletely treated. The sensitivities of plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI to these incompletely treated nodules were 42% (10/24), 46% (11/24), 88% (21/24), and 79% (19/24), respectively. Eighty percent (19 nodules) of the 24 incompletely treated nodules were located within a depth of less than 8 cm. The sensitivities of plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI to these superficial incompletely treated nodules were 37% (7/19), 53% (10/19), 100% (19/19), and 74% (14/19), respectively. In contrast, the sensitivities of each modality to deeply located nodules were 60% (3/5), 20% (1/5), 40% (2/5), and 100% (5/5), respectively. Plain CT and power Doppler sonography had a low sensitivity to HCC nodules incompletely treated with TAE. Except for those that were deeply located, contrast-enhanced harmonic sonography showed the highest sensitivity in detecting incompletely treated HCC nodules.
Korte, Erik A; Pozzi, Nicole; Wardrip, Nina; Ayyoubi, M Tayyeb; Jortani, Saeed A
2018-07-01
There are 13 million blood transfusions each year in the US. Limitations in the donor pool, storage capabilities, mass casualties, access in remote locations and reactivity of donors all limit the availability of transfusable blood products to patients. HBOC-201 (Hemopure®) is a second-generation glutaraldehyde-polymer of bovine hemoglobin, which can serve as an "oxygen bridge" to maintain oxygen carrying capacity while transfusion products are unavailable. Hemopure presents the advantages of extended shelf life, ambient storage, and limited reactive potential, but its extracellular location can also cause significant interference in modern laboratory analyzers similar to severe hemolysis. Observed error in 26 commonly measured analytes was determined on 4 different analytical platforms in plasma from a patient therapeutically transfused Hemopure as well as donor blood spiked with Hemopure at a level equivalent to the therapeutic loading dose (10% v/v). Significant negative error ratios >50% of the total allowable error (>0.5tAE) were reported in 23/104 assays (22.1%), positive bias of >0.5tAE in 26/104 assays (25.0%), and acceptable bias between -0.5tAE and 0.5tAE error ratio was reported in 44/104 (42.3%). Analysis failed in the presence of Hemopure in 11/104 (10.6%). Observed error is further subdivided by platform, wavelength, dilution and reaction method. Administration of Hemopure (or other hemoglobin-based oxygen carriers) presents a challenge to laboratorians tasked with analyzing patient specimens. We provide laboratorians with a reference to evaluate patient samples, select optimal analytical platforms for specific analytes, and predict possible bias beyond the 4 analytical platforms included in this study. Copyright © 2018 Elsevier B.V. All rights reserved.
Conlin, Paul R; Asefzadeh, Baharak; Pasquale, Louis R; Selvin, Gerald; Lamkin, Rebecca; Cavallerano, Anthony A
2015-12-01
Digital retinal imaging using store-and-forward technology is used to screen for diabetic retinopathy (DR). Its usefulness in detecting non-diabetic eye diseases is uncertain. We determined the level of agreement between teleretinal imaging supplemented with visual acuity and intraocular pressure (IOP) measurements (ie, technology-assisted eye (TAE) exam) and a comprehensive eye exam in evaluation for DR and non-diabetic ocular conditions. We conducted a prospective, observational study with two parallel evaluations. Patients with diabetes (n=317) had a TAE exam and a comprehensive eye exam on the same day. A subset of participants with normal baseline exams (n=72) had follow-up exams 1 year later. We measured the level of agreement for referable ocular findings. Agreement for referable ocular findings was moderate (n=389, agreement: 77%; κ: 0.55), due in part to ungradable exams (22%). However, about half of the ungradable exams had findings that warranted referral. There was substantial agreement for follow-up exams (n=72, agreement: 93%; κ: 0.63). Among all gradable exams (n=303), the TAE exam had 86% sensitivity and 84% specificity for referable ocular findings, with high agreement (≥94%) for DR and other major ocular diagnoses. There was moderate-to-substantial agreement between a TAE exam and a comprehensive eye exam for referable ocular findings in patients with diabetes. Ungradable exams were a frequent marker of ocular pathology. Teleretinal imaging may be a useful evaluation for both diabetic and non-diabetic ocular conditions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moschouris, Hippocrates, E-mail: hipmosch@gmail.co; Malagari, Katerina; Kornezos, Ioannis
2010-12-15
The purpose of this study was to describe and evaluate the findings of unenhanced ultrasonography (US) and contrast-enhanced ultrasonography (CEUS) when these modalities are applied during transarterial embolization (TAE) or transarterial chemoembolization (TACE) of liver tumors. Sixteen tumors (9 hepatocellular carcinomas, 5 metastases from colorectal cancer, and 2 hemangiomas) were treated with TAE with microspheres and/or TACE with drug-eluting beads. All of these lesions were studied with intraprocedural unenhanced US and 12 were studied with intraprocedural CEUS. For the latter, a second-generation echo-enhancer (SonoVue; Bracco, Milan, Italy) and a low mechanical index technique were used. Intraprocedural findings were classified accordingmore » to an arbitrary scale and were compared with pretreatment imaging (CEUS and computed tomography or CEUS and magnetic resonance imaging), with postembolization angiography, and with follow-up results. On unenhanced intraprocedural US, 13 of 16 tumors demonstrated intralesional high-level echoes of varying extent. These feature correlated poorly (r = 0.33, p = 0.097) with and generally underestimated the actual extent of necrosis. Exceptionally, high-level echoes that occupied the largest part of the treated lesions were associated with >50% tumor necrosis. Intraprocedural CEUS clearly depicted immediate partial or complete disappearance of tumor enhancement as a result of TAE/TACE. Three of 6 tumors with complete devascularization on postembolization angiogram showed residual enhancement on intraprocedural CEUS. Intraprocedural CEUS findings correlated closely (r = 0.91, p = 0.002) with follow-up findings. Intraprocedural sonography, particularly with echo-enhancers, could be used for intraprocedural monitoring in selected cases of liver tumors that undergo TAE or TACE.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanahashi, Yukichi; Goshima, Satoshi, E-mail: gossy@par.odn.ne.jp; Kondo, Hiroshi
PurposeTo identify predictive factors for embolic material conversion to N-butyl cyanoacrylate (NBCA) for the treatment of primary postpartum hemorrhage (PPH) after failed transcatheter arterial embolization (TAE) using gelatin sponge (GS).Materials and MethodsInstitutional review board approval was obtained. We retrospectively studied 62 consecutive women with primary PPH who underwent TAE between January 2006 and March 2015. Five of them were excluded for the following: cardiopulmonary arrest at arrival (n = 1), uterine inversion (n = 1), and hysterectomy after TAE (n = 3). Remaining 57 women (age range, 21–43 years; mean, 32.6 years) comprised study population. TAE was initially performed using GS in all cases andmore » then converted to NBCA after two embolizations using GS with persistent hemodynamic instability or vaginal bleeding. The patients’ background, uterine height, vital signs, laboratory tests, disseminated intravascular coagulation score, and details of procedure were reviewed. Univariate and multivariate analyses were performed to determine factors related to embolic material conversion.ResultsTechnical success rate was 100%. Fourteen patients (25%) needed embolic material conversion to NBCA. Univariate analysis showed that uterine height, systolic blood pressure (sBP), and hemoglobin level were significantly related to embolic material conversion to NBCA (P = 0.029, 0.030, and 0.042). Logistic regression analysis showed that uterine height (odds ratio, 1.37; P = 0.025) and sBP (odds ratio, 0.96; P = 0.003) were associated with embolic material conversion to NBCA.ConclusionUterine height and sBP can be predictive factors for embolic material conversion to NBCA for the treatment of PPH.Level of EvidenceLevel 4, Case Control Study.« less
Energy absorption due to spatial resonance of Alfven waves at continuum tip
NASA Astrophysics Data System (ADS)
Chen, Eugene; Berk, Herb; Breizman, Boris; Zheng, Linjin
2011-10-01
We investigate the response of tokamak plasma to an external driving source. An impedance-like function depending on the driving frequency that is growing at a small rate, is calculated and interpreted with different source profiles. Special attention is devoted to the case where driving frequency approaches that of the TAE continuum tip. The calculation can be applied to the estimation of TAE damping rate by analytically continuing the inverse of the impedance function to the lower half plane. The root of the analytic continuation corresponds to the existence of a quasi-mode, from which the damping rate can be found.
Benchmark quality total atomization energies of small polyatomic molecules
NASA Astrophysics Data System (ADS)
Martin, Jan M. L.; Taylor, Peter R.
1997-05-01
Successive coupled-cluster [CCSD(T)] calculations in basis sets of spdf, spdfg, and spdfgh quality, combined with separate Schwartz-type extrapolations A+B/(l+1/2)α of the self-consistent field (SCF) and correlation energies, permit the calculations of molecular total atomization energies (TAEs) with a mean absolute error of as low as 0.12 kcal/mol. For the largest molecule treated, C2H4, we find ∑D0=532.0 kcal/mol, in perfect agreement with experiment. The aug-cc-pV5Z basis set recovers on average about 99% of the valence correlation contribution to the TAE, and essentially the entire SCF contribution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grasso, Rosario Francesco, E-mail: r.grasso@unicampus.it; Cazzato, Roberto Luigi; Luppi, Giacomo
Arteriovenous malformation (AVM) of the pancreas is a rare condition. Most patients are asymptomatic or alternatively may present with a wide spectrum of symptoms. Traditionally, surgery has been considered the treatment of choice; however, alternative approaches, such as transcatheter embolization (TAE), may be proposed. We report a case of a 48-year-old man with a pancreatic head AVM, presenting with upper abdominal pain and slight anemia. The patient refused surgery and underwent TAE by means of ethylene-vinyl alcohol copolymer (EVOH). At 3 months follow-up, the patient was able to eat regularly, with no residual pain and no signs of anemia.
PROCESS OF COATING METALS WITH BISMUTH OR BISMUTH-BASE ALLOYS
Beach, J.G.
1958-01-28
A method is described for producing coatings of bismuth or bismuth alloys on a metal base. This is accomplished by electrodepositing the bismuth from an aqueous solution of BiCl/sub 3/, and by making the metal base alternately the cathode and the anode, the cathode periods being twice as long as the anode periods. In one embodiment a nickel coating is first electrodeposited in a known way, and this nickel plated piece is tae base upon which tae bismuth is deposited by the process of this patent. The coated piece is then heat treated to produce a homogeneous Ni--Bi alloy by diffusion.
An overview of the catalog manager
NASA Technical Reports Server (NTRS)
Irani, Frederick M.
1986-01-01
The Catalog Manager (CM) is being used at the Goddard Space Flight Center in conjunction with the Land Analysis System (LAS) running under the Transportable Applications Executive (TAE). CM maintains a catalog of file names for all users of the LAS system. The catalog provides a cross-reference between TAE user file names and fully qualified host-file names. It also maintains information about the content and status of each file. A brief history of CM development is given and a description of naming conventions, catalog structure and file attributes, and archive/retrieve capabilities is presented. General user operation and the LAS user scenario are also discussed.
Kohl, T; Müller, A; Tchatcheva, K; Achenbach, S; Gembruch, U
2005-12-01
Because of insufficient imaging by maternal transabdominal fetal echocardiography (TAE) in a human fetus with aortic atresia, imperforate atrial septum and progressive cardiac failure, we assessed the feasibility of fetal transesophageal echocardiography (TEE) as a monitoring tool during fetal cardiac intervention at 24 + 6 weeks of gestation. Percutaneous fetoscopic intraesophageal deployment of the ultrasound catheter was achieved and did not result in any maternal or fetal complications. Fetal TEE permitted substantially clearer definition of fetal cardiac anatomy and intracardiac device manipulations than conventional maternal TAE. Despite the employment of various devices, no sufficiently large opening could be achieved within the atrial septum. Although the fetus tolerated the procedure remarkably well and satisfactory fetoplacental flow could be documented at the end of the procedure, the fetus died from progressive cardiac failure 3 days after the intervention. Fetoscopic TEE is feasible in the human fetus and permits substantially clearer definition of fetal cardiac anatomy and intracardiac manipulations than conventional maternal TAE. Based on the observation of spontaneous closure of multiple iatrogenic perforations of the atrial septum, specialized devices are required in order to improve the technical success rate of septoplasty methods and hence the survival odds of these high-risk patients.
One-dimensional energetic particle quasilinear diffusion for realistic TAE instabilities
NASA Astrophysics Data System (ADS)
Duarte, Vinicius; Ghantous, Katy; Berk, Herbert; Gorelenkov, Nikolai
2014-10-01
Owing to the proximity of the characteristic phase (Alfvén) velocity and typical energetic particle (EP) superthermal velocities, toroidicity-induced Alfvén eigenmodes (TAEs) can be resonantly destabilized endangering the plasma performance. Thus, it is of ultimate importance to understand the deleterious effects on the confinement resulting from fast ion driven instabilities expected in fusion-grade plasmas. We propose to study the interaction of EPs and TAEs using a line broadened quasilinear model, which captures the interaction in both regimes of isolated and overlapping modes. The resonance particles diffuse in the phase space where the problem essentially reduces to one dimension with constant kinetic energy and the diffusion mainly along the canonical toroidal angular momentum. Mode structure and wave particle resonances are computed by the NOVA code and are used in a quasilinear diffusion code that is being written to study the evolution of the distribution function, under the assumption that they can be considered virtually unalterable during the diffusion. A new scheme for the resonant particle diffusion is being proposed that builds on the 1-D nature of the diffusion from a single mode, which leads to a momentum conserving difference scheme even when there is mode overlap.
Overview of the land analysis system (LAS)
Quirk, Bruce K.; Olseson, Lyndon R.
1987-01-01
The Land Analysis System (LAS) is a fully integrated digital analysis system designed to support remote sensing, image processing, and geographic information systems research. LAS is being developed through a cooperative effort between the National Aeronautics and Space Administration Goddard Space Flight Center and the U. S. Geological Survey Earth Resources Observation Systems (EROS) Data Center. LAS has over 275 analysis modules capable to performing input and output, radiometric correction, geometric registration, signal processing, logical operations, data transformation, classification, spatial analysis, nominal filtering, conversion between raster and vector data types, and display manipulation of image and ancillary data. LAS is currently implant using the Transportable Applications Executive (TAE). While TAE was designed primarily to be transportable, it still provides the necessary components for a standard user interface, terminal handling, input and output services, display management, and intersystem communications. With TAE the analyst uses the same interface to the processing modules regardless of the host computer or operating system. LAS was originally implemented at EROS on a Digital Equipment Corporation computer system under the Virtual Memorial System operating system with DeAnza displays and is presently being converted to run on a Gould Power Node and Sun workstation under the Berkeley System Distribution UNIX operating system.
Adaptation to implied tilt: extensive spatial extrapolation of orientation gradients
Roach, Neil W.; Webb, Ben S.
2013-01-01
To extract the global structure of an image, the visual system must integrate local orientation estimates across space. Progress is being made toward understanding this integration process, but very little is known about whether the presence of structure exerts a reciprocal influence on local orientation coding. We have previously shown that adaptation to patterns containing circular or radial structure induces tilt-aftereffects (TAEs), even in locations where the adapting pattern was occluded. These spatially “remote” TAEs have novel tuning properties and behave in a manner consistent with adaptation to the local orientation implied by the circular structure (but not physically present) at a given test location. Here, by manipulating the spatial distribution of local elements in noisy circular textures, we demonstrate that remote TAEs are driven by the extrapolation of orientation structure over remarkably large regions of visual space (more than 20°). We further show that these effects are not specific to adapting stimuli with polar orientation structure, but require a gradient of orientation change across space. Our results suggest that mechanisms of visual adaptation exploit orientation gradients to predict the local pattern content of unfilled regions of space. PMID:23882243
Endovascular Therapy of Bronchial Artery Aneurysm: Five Cases With Six Aneurysms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lue, Peng-Hua, E-mail: whycn77@sina.com; Wang Lifu; Su Yusheng
2011-06-15
The objective of this study was to investigate the effect of transcatheter arterial embolization (TAE) with N-butyl-2-cyanoacrylate (NBCA)-Lipiodol mixture in patients with bronchial artery aneurysm (BAA). From January 2005 to January 2010, five patients presenting hemoptysis with six BAAs were treated with NBCA-Lipiodol mixture, including intra-aneurysm embolization (IAE) in one patient. Adjuvant embolization with spherical polyvinyl alcohol (PVA) embolic microparticles or NBCA was first performed to embolize the distal engorged bronchiectatic arteries. Bronchial arterial angiography showed six BAAs (four in the right lobe and two in the left lobe) and some engorged, tortuous bronchial arteries. TAE through microcatheter was successfulmore » in all cases. Postembolization angiogram demonstrated the NBCA cast and total occlusion of BAAs and bronchiectatic engorged vessels. After these procedures, hemoptysis completely disappeared in all patients. Follow-up computed tomography (CT) scan was performed at an average of 3 months (range 2 to 6), which showed no enhancement of BAAs and accumulation of NBCA. TAE is a minimally invasive, effective, and reliable approach for treatment for patients with BAA. NBCA-Lipiodol mixture provides a good choice for treatment of BAA, especially when catheterization of the efferent branches is impossible.« less
Ke, Shan; Gao, Jun; Kong, Jian; Ding, Xue-Mei; Niu, Hai-Gang; Xin, Zong-Hai; Ning, Chun-Min; Guo, Shi-Gang; Li, Xiao-Long; Zhang, Long; Dong, Yong-Hong; Sun, Wen-Bing
2016-01-01
Abstract This study investigated the effectiveness of a new strategy, repeated radiofrequency (RF) ablation combined with ablated lesion elimination following transarterial chemoembolization (TACE)/transarterial embolization (TAE), for solitary huge hepatocellular carcinoma (SHHCC) 10 cm or larger. From July 2008 to October 2015, 39 consecutive patients with SHHCC were screened. Of these, 12 were treated with TACE/TAE and repeated RF ablation (TACE/TAE + RF ablation group) and the remaining 27 patients were treated with the aforementioned new strategy (new strategy group). Local tumor progression (LTP)-free survival, intrahepatic distant recurrence (IDR)-free survival, and overall survival (OS) rates were obtained using the Kaplan–Meier method. Univariate and multivariate analyses were performed on several clinicopathological variables to identify factors affecting long-term outcome and intrahepatic recurrence. Correlation analysis was also performed. The 1-, 2-, and 3-year LTP-free survival rates and OS rates were significantly higher in the new strategy group than in the TACE/TAE + RF ablation group (82.9% vs 58.3%, 73.9% vs 29.2%, 18.5% vs 9.7%, P = 0.002; 92.0% vs 75.0%, 84.0% vs 33.3%, 32.7% vs 16.7%, P = 0.025). However, there was no significant difference between the 2 groups in the 1-, 2-, and 3-year IDR-free survival rates (P = 0.108). Using univariate analysis, alpha-fetoprotein (AFP > 200 ng/mL), ablative margin (AM > 1.0 cm), and well-differentiated cells were found to be significant factors for predicting LTP, IDR, and OS. Surgical elimination was found to be a significant factor only for predicting OS. In multivariate analyses, AFP (>200 ng/mL), AM (>1.0 cm), and well-differentiated cells were found to be significant independent factors linked to LTP, IDR, and OS. Correlation analysis indicated that AM > 1.0 cm was strongly associated with surgical elimination (P < 0.001, correlation coefficient = 0.877). For patients with SHHCC who were initially excluded from surgery, the new strategy including repeated RF ablation combined with ablated lesion elimination following TACE/TAE should now be considered as an alternative treatment. PMID:27100425
Injuries in martial arts: a comparison of five styles
Zetaruk, M; Violan, M; Zurakowski, D; Micheli, L
2005-01-01
Objective: To compare five martial arts with respect to injury outcomes. Methods: A one year retrospective cohort was studied using an injury survey. Data on 263 martial arts participants (Shotokan karate, n = 114; aikido, n = 47; tae kwon do, n = 49; kung fu, n = 39; tai chi, n = 14) were analysed. Predictor variables included age, sex, training frequency (⩽3 h/week v >3 h/week), experience (<3 years v ⩾3 years), and martial art style. Outcome measures were injuries requiring time off from training, major injuries (⩾7 days off), multiple injuries (⩾3), body region, and type of injury. Logistic regression was used to determine odds ratios (OR) and confidence intervals (CI). Fisher's exact test was used for comparisons between styles, with a Bonferroni correction for multiple comparisons. Results: The rate of injuries, expressed as percentage of participants sustaining an injury that required time off training a year, varied according to style: 59% tae kwon do, 51% aikido, 38% kung fu, 30% karate, and 14% tai chi. There was a threefold increased risk of injury and multiple injury in tae kwon do than karate (p<0.001). Subjects ⩾18 years of age were at greater risk of injury than younger ones (p<0.05; OR 3.95; CI 1.48 to 9.52). Martial artists with at least three years experience were twice as likely to sustain injury than less experienced students (p<0.005; OR 2.46; CI 1.51 to 4.02). Training >3 h/week was also a significant predictor of injury (p<0.05; OR 1.85; CI 1.13 to 3.05). Compared with karate, the risks of head/neck injury, upper extremity injury, and soft tissue injury were all higher in aikido (p<0.005), and the risks of head/neck, groin, and upper and lower extremity injuries were higher in tae kwon do (p<0.001). No sex differences were found for any of the outcomes studied. Conclusions: There is a higher rate of injury in tae kwon do than Shotokan karate. Different martial arts have significantly different types and distribution of injuries. Martial arts appear to be safe for young athletes, particularly those at beginner or intermediate levels. PMID:15618336
Definition and testing of the hydrologic component of the pilot land data system
NASA Technical Reports Server (NTRS)
Ragan, Robert M.; Sircar, Jayanta K.
1987-01-01
The specific aim was to develop within the Pilot Land Data System (PLDS) software design environment, an easily implementable and user friendly geometric correction procedure to readily enable the georeferencing of imagery data from the Advanced Very High Resolution Radiometer (AVHRR) onboard the NOAA series spacecraft. A software subsystem was developed within the guidelines set by the PLDS development environment utilizing NASA Goddard Space Flight Center (GSFC) Image Analysis Facility's (IAF's) Land Analysis Software (LAS) coding standards. The IAS current program development environment, the Transportable Applications Executive (TAE), operates under a VAX VMS operating system and was used as the user interface. A brief overview of the ICARUS algorithm that was implemented in the set of functions developed, is provided. The functional specifications decription is provided, and a list of the individual programs and directory names containing the source and executables installed in the IAF system are listed. A user guide is provided for the LAS system documentation format for the three functions developed.
Late-onset severe biliary bleeding after endoscopic pigtail plastic stent insertion.
Yasuda, Muneji; Sato, Hideki; Koyama, Yuki; Sakakida, Tomoki; Kawakami, Takumi; Nishimura, Takeshi; Fujii, Hideki; Nakatsugawa, Yoshikazu; Yamada, Shinya; Tomatsuri, Naoya; Okuyama, Yusuke; Kimura, Hiroyuki; Ito, Takaaki; Morishita, Hiroyuki; Yoshida, Norimasa
2017-01-28
Here, we report our experience with a case of severe biliary bleeding due to a hepatic arterial pseudoaneurysm that had developed 1 year after endoscopic biliary plastic stent insertion. The patient, a 78-year-old woman, presented with hematemesis and obstructive jaundice. Ruptured hepatic arterial pseudoaneurysm was diagnosed, which was suspected to have been caused by long-term placement of an endoscopic retrograde biliary drainage (ERBD) stent. This episode of biliary bleeding was successfully treated by transarterial embolization (TAE). Pseudoaneurysm leading to hemobilia is a rare but potentially fatal complication in patients with long-term placement of ERBD. TAE is a minimally invasive procedure that offers effective treatment for biliary bleeding.
Endovascular Treatment in Emergency Setting of Acute Arterial Injuries After Orthopedic Surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carrafiello, Gianpaolo, E-mail: gcarraf@tin.it; Fontana, Federico, E-mail: fede.fontana@libero.it; Mangini, Monica, E-mail: monica.mangini@tin.it
Purpose: To assess the feasibility and effectiveness of emergency endovascular treatment of acute arterial injuries after orthopedic surgery. Materials and Methods: Fifteen patients (mean age 68.3 years) with acute arterial injuries after orthopedic surgery were observed, in particular, 5 patients with pseudoaneurysm, 9 patients with active bleeding, and 1 patient with arterial dissection. Transarterial embolization (TAE) and positioning of covered and noncovered stents were the treatments performed. Follow-up after stent implantation (mean 36 months) was performed with color Doppler US (CDU) at 1, 3, 6, and 12 months and yearly thereafter. Plain X-ray was performed to evidence dislodgment or fracturemore » of the graft. A minimum of 12 months' follow-up is available after TAE. Results: Immediate technical success was obtained in all cases. No major complications occurred. Overall clinical success rate was 100%. During mean follow-up, stent-graft occlusions did not occurred. No recurrence and/or consequence of TAE was registered during a minimum follow-up of 12 months. Conclusions: Percutaneous treatment is a feasible and safe tool for treating arterial injuries because it can provide fast and definitive resolution of the damage. This low-invasiveness approach can be proposed as first-line treatment in patients with acute injuries after orthopedic surgery.« less
Potential medical applications of TAE
NASA Technical Reports Server (NTRS)
Fahy, J. Ben; Kaucic, Robert; Kim, Yongmin
1986-01-01
In cooperation with scientists in the University of Washington Medical School, a microcomputer-based image processing system for quantitative microscopy, called DMD1 (Digital Microdensitometer 1) was constructed. In order to make DMD1 transportable to different hosts and image processors, we have been investigating the possibility of rewriting the lower level portions of DMD1 software using Transportable Applications Executive (TAE) libraries and subsystems. If successful, we hope to produce a newer version of DMD1, called DMD2, running on an IBM PC/AT under the SCO XENIX System 5 operating system, using any of seven target image processors available in our laboratory. Following this implementation, copies of the system will be transferred to other laboratories with biomedical imaging applications. By integrating those applications into DMD2, we hope to eventually expand our system into a low-cost general purpose biomedical imaging workstation. This workstation will be useful not only as a self-contained instrument for clinical or research applications, but also as part of a large scale Digital Imaging Network and Picture Archiving and Communication System, (DIN/PACS). Widespread application of these TAE-based image processing and analysis systems should facilitate software exchange and scientific cooperation not only within the medical community, but between the medical and remote sensing communities as well.
Hybrid simulations of Alfvén modes driven by energetic particles
NASA Astrophysics Data System (ADS)
Zhu, J.; Ma, Z. W.; Wang, S.
2016-12-01
A hybrid kinetic-magnetohydrodynamic code (CLT-K) is developed to study nonlinear dynamics of Alfvén modes driven by energetic particles (EP). A n = 2 toroidicity-induced discrete shear Alfvén eigenmode (TAE)-type energetic particle mode (EPM) with two dominant poloidal harmonics (m = 2 and 3) is first excited and its frequency remains unchanged in the early phase. Later, a new branch of the n = 2 frequency with a single dominant poloidal mode (m = 3) splits from the original TAE-type EPM. The new single m EPM (m = 3) slowly moves radially outward with the downward chirping of the frequency and the mode amplitude remains at a higher level. The original EPM remains at its original position without the frequency chirping, but its amplitude decays with time. Finally, the m = 3 EPM becomes dominant and the frequency falls into the β-induced gap of the Alfvén continuum. The redistribution of the δf in the phase space is consistent with the mode frequency downward chirping and the drifting direction of the resonance region is mainly due to the biased free energy profile. The transition from a TAE-type EPM to a single m EPM is mainly caused by extension of the p = 0 trapped particle resonance in the phase space.
Vaghela, Madhuri; Iyer, Krishna; Pandita, Nancy
2018-04-01
Gymnema sylvestre R. Br. is a well-known Indian medicinal herb. Gymnemic acids are pentacyclic triterpenes saponins and active phytoconstituents of Gymnema sylvestre. The study aimed at evaluation of the in vitro rat liver cytochrome P450 (CYP) inhibition potential of extracts and total gymnemic acid (TA)-enriched fractions from G. sylvestre. Standardization of G. sylvestre [ethanolic (EL), hydroethanolic (HE), total acid of ethanolic (TAE), total acid of hydroethanolic (TAHE) and total acid of aqueous (TAAQ) extract] was done with respect to deacyl gymnemic acid (DAGA), using reverse phase-high performance liquid chromatography (RP-HPLC). Total triterpenoid content was determined by vanillin perchloric acid assay. Total triterpene content was found to be the highest in TAAQ (59.86 ± 0.005% w/w) and TAE (49.77 ± 0.009% w/w). TAAQ showed IC 50 ≤ 50 µg/ml for all selected CYP activities. Testosterone 6β-hydroxylation was strongly inhibited by TAE (IC 50 : 15.48 ± 2.13 µg/ml) and was moderately by TAAQ and EL with IC 50 ≥ 50 µg/ml. Flurbiprofen 4'-hydroxylation was subject to strong, weak and moderate inhibition by TAAQ (IC 50 : 34.67 ± 1.38 µg/ml), TAE (IC 50 : ≥ 50 µg/ml) and EL (IC 50 : > 50 µg/ml), respectively. Dextromethorphan O-demethylation was inhibited by TAHE and TAAQ. In vitro inhibition studies suggested that TA strongly inhibits activity of selected CYP. This inhibition may possibly be due to triterpenoids and gymnemic acids that have been reported to be present in it. Data also suggest a potential for possible in vivo herb-drug interactions involving G. sylvestre and other medications that are metabolized by the same CYP.
Modeling of Nonlinear Beat Signals of TAE's
NASA Astrophysics Data System (ADS)
Zhang, Bo; Berk, Herbert; Breizman, Boris; Zheng, Linjin
2012-03-01
Experiments on Alcator C-Mod reveal Toroidal Alfven Eigenmodes (TAE) together with signals at various beat frequencies, including those at twice the mode frequency. The beat frequencies are sidebands driven by quadratic nonlinear terms in the MHD equations. These nonlinear sidebands have not yet been quantified by any existing codes. We extend the AEGIS code to capture nonlinear effects by treating the nonlinear terms as a driving source in the linear MHD solver. Our goal is to compute the spatial structure of the sidebands for realistic geometry and q-profile, which can be directly compared with experiment in order to interpret the phase contrast imaging diagnostic measurements and to enable the quantitative determination of the Alfven wave amplitude in the plasma core
Dao, Pascal; Jarray, Rafika; Le Coq, Johanne; Lietha, Daniel; Loukaci, Ali; Lepelletier, Yves; Hadj-Slimane, Réda; Garbay, Christiane; Raynaud, Françoise; Chen, Huixiong
2013-08-15
We report herein the synthesis of novel diarylamino-1,3,5-triazine derivatives as FAK (focal adhesion kinase) inhibitors and the evaluation of their anti-angiogenic activity on HUVEC cells. Generally, the effects of these compounds on endothelial cells could be correlated with their kinase inhibitory activity. The most efficient compounds displayed inhibition of viability against HUVEC cells in the micromolar range, as observed with TAE-226, which was designed by Novartis Pharma AG. X-ray crystallographic analysis of the co-crystal structure for compound 34 revealed that the mode of interaction with the FAK kinase domain is highly similar to that observed in the complex of TAE-226. Copyright © 2013 Elsevier Ltd. All rights reserved.
Savic, Lynn Jeanette; Chapiro, Julius; Geschwind, Jean-François
2017-06-01
In this issue of Radiology, Gade et al ( 1 ) describe a unique mechanism of hepatocellular carcinoma (HCC) cells for surviving ischemia induced by transarterial embolization (TAE)/transarterial chemoembolization (TACE) in a state of cell cycle arrest-a function that may serve as a defensive shield against conventional chemotherapeutic agents. This finding adds to our knowledge and establishes a previously poorly understood mechanism of chemoresistance in HCC. As the Achilles heel in terms of this process, a concurrent upregulation of autophagic flux as an adaptive response to TAE-like ischemia was found by the authors. This is a targetable mechanism that can potentially be exploited for combined therapeutic approaches of embolotherapy and autophagy inhibition in HCC.
The martial arts and mental health: the challenge of managing energy.
Seitz, F C; Olson, G D; Locke, B; Quam, R
1990-04-01
The effective management of energy is an important dimension in the martial arts as well as the mental health professions. The Oriental concept of Ki is described, noting its Indian, Chinese, and Japanese development. Ki and the transfer of energy is studied through the martial encounter, using concepts borrowed from Japanese swordsmanship. Ki is also discussed from a developmental context as youngsters progress in Tae Kwon Do training. In examining the disciplines of Aikido, Tae Kwon Do, and Karate, it becomes clear that more is involved than kicking, punching, and throwing bodies on the floor. These martial arts have some important statements to make in the area of mental health, particularly in terms of energy--within our bodies, psyches, interpersonal relationships, and the universe.
Transfer-arm evaporator cell for rapid loading and deposition of organic thin films.
Greiner, M T; Helander, M G; Wang, Z B; Lu, Z H
2009-12-01
Described herein is a transfer-arm evaporator cell (TAE-cell), which allows for rapid loading of materials into vacuum for low-temperature sublimation deposition of thin films. This design can be incorporated with an existing analysis system for convenient in situ thin film characterization. This evaporator is especially well suited for photoemission characterization of organic semiconductor interfaces. Photoemission is one of the most important techniques for characterizing such, however, it generally requires in situ sample preparation. The ease with which materials can be loaded and evaporated with this design increases the throughput of in situ photoemission characterization, and broadens the research scope of the technique. Here, we describe the design, operation, and performance of the TAE-cell.
1993-03-01
cervV epa Addm Ing. J.A. van (3ooI - 12-02-1993 It7T- PAPOTNCNTAE g,: Accesion For Frederikkaze~rne, gebouw 140 OGRBIER TS CAI T v/ d Burchlaafl 31 HPC...16A r~l D TIC -;S TEL. 070-3166394/6395 ONGERUBRICEERD) !’ ,ro’ ;Cc FAX. (31) 070-.3166202 Srevtil:JSl--to ElostbUs 90701 Saiqwag ......zto I...Tabel I geeft d onderdelen van de TNO~~~~-SC e e fiknemattnozc a ei etU rnebe[I] becrvnSB Tae I ljtvnodreediqu atvscinvnd I-C TaeD ef e onder d n o
Usui, Kenji; Sakamoto, Kaoru; Akabane, Kentaro; Hayasaka, Kazuki; Mizuki, Toru; Yagi, Yutaka; Shirahata, Yasuhiro; Ichikawa, Hiroshi; Hanyu, Takaaki; Ishikawa, Takashi; Kameyama, Hitoshi; Suzuki, Satoshi; Saito, Kiyohiro; Wakai, Toshifumi
2017-11-01
An 81-year-oldwoman with advancedgastric cancer was referredto our hospital. Preoperative contrast-enhancedCT revealeda roundcalcification of the splenic hilum with 15mm in diameter as a splenic artery aneurysm. She underwent transcatheter arterial embolization(TAE)for the splenic artery aneurysm. Celiac artery angiography showedcollateral arterial network of the spleen from left gastric artery. Surgery for the gastric cancer was performed1 4 days after TAE. We cut the right gastric andbilateral epigastric arteries. After the left gastric artery clamping, we performedintraoperative indocyanine green(ICG)fluorography. ICG fluorography confirmedthat the bloodflow of the upper thirdof the stomach andspleen were maintained. We safely performed distal gastrectomy, and the postoperative course was uneventful.
Method and system for rendering and interacting with an adaptable computing environment
Osbourn, Gordon Cecil [Albuquerque, NM; Bouchard, Ann Marie [Albuquerque, NM
2012-06-12
An adaptable computing environment is implemented with software entities termed "s-machines", which self-assemble into hierarchical data structures capable of rendering and interacting with the computing environment. A hierarchical data structure includes a first hierarchical s-machine bound to a second hierarchical s-machine. The first hierarchical s-machine is associated with a first layer of a rendering region on a display screen and the second hierarchical s-machine is associated with a second layer of the rendering region overlaying at least a portion of the first layer. A screen element s-machine is linked to the first hierarchical s-machine. The screen element s-machine manages data associated with a screen element rendered to the display screen within the rendering region at the first layer.
Chemical-genetic profile analysis of five inhibitory compounds in yeast.
Alamgir, Md; Erukova, Veronika; Jessulat, Matthew; Azizi, Ali; Golshani, Ashkan
2010-08-06
Chemical-genetic profiling of inhibitory compounds can lead to identification of their modes of action. These profiles can help elucidate the complex interactions between small bioactive compounds and the cell machinery, and explain putative gene function(s). Colony size reduction was used to investigate the chemical-genetic profile of cycloheximide, 3-amino-1,2,4-triazole, paromomycin, streptomycin and neomycin in the yeast Saccharomyces cerevisiae. These compounds target the process of protein biosynthesis. More than 70,000 strains were analyzed from the array of gene deletion mutant yeast strains. As expected, the overall profiles of the tested compounds were similar, with deletions for genes involved in protein biosynthesis being the major category followed by metabolism. This implies that novel genes involved in protein biosynthesis could be identified from these profiles. Further investigations were carried out to assess the activity of three profiled genes in the process of protein biosynthesis using relative fitness of double mutants and other genetic assays. Chemical-genetic profiles provide insight into the molecular mechanism(s) of the examined compounds by elucidating their potential primary and secondary cellular target sites. Our follow-up investigations into the activity of three profiled genes in the process of protein biosynthesis provided further evidence concerning the usefulness of chemical-genetic analyses for annotating gene functions. We termed these genes TAE2, TAE3 and TAE4 for translation associated elements 2-4.
Usage of heparan sulfate, integrins, and FAK in HPV16 infection
Abban, Cynthia Y.; Meneses, Patricio I.
2010-01-01
Human Papillomavirus Type 16 (HPV16) is the major causative agent of cervical cancer. Studies regarding the early binding and signaling molecules that play a significant role in infection are still lacking. The current study analyses the role of heparan sulfate, integrins, and the signaling molecule FAK in HPV16 infection of human adult keratinocytes cell line (HaCaTs). Our data demonstrate that infection requires the binding of viral particles to heparan sulfate followed by activation of focal adhesion kinase through an integrin. Infections were reduced in the presence of the FAK inhibitor, TAE226. TAE226 was observed to inhibit viral entry to the early endosome a known infectious route. These findings suggest that FAK can serve as a novel target for antiviral therapy. PMID:20441998
Kim, Taehyeung; Park, Ah Yeon; Baek, Younghwa; Cha, Seongwon
2017-01-01
Circulating lipid ratios are considered predictors of cardiovascular risks and metabolic syndrome, which cause coronary heart diseases. One constitutional type of Korean medicine prone to weight accumulation, the Tae-Eum type, predisposes the consumers to metabolic syndrome, hypertension, diabetes mellitus, etc. Here, we aimed to identify genetic variants for lipid ratios using a genome-wide association study (GWAS) and followed replication analysis in Koreans and constitutional subgroups. GWASs in 5,292 individuals of the Korean Genome and Epidemiology Study and replication analyses in 2,567 subjects of the Korea medicine Data Center were performed to identify genetic variants associated with triglyceride (TG) to HDL cholesterol (HDLC), LDL cholesterol (LDLC) to HDLC, and non-HDLC to HDLC ratios. For subgroup analysis, a computer-based constitution analysis tool was used to categorize the constitutional types of the subjects. In the discovery stage, seven variants in four loci, three variants in three loci, and two variants in one locus were associated with the ratios of log-transformed TG:HDLC (log[TG]:HDLC), LDLC:HDLC, and non-HDLC:HDLC, respectively. The associations of the GWAS variants with lipid ratios were replicated in the validation stage: for the log[TG]:HDLC ratio, rs6589566 near APOA5 and rs4244457 and rs6586891 near LPL; for the LDLC:HDLC ratio, rs4420638 near APOC1 and rs17445774 near C2orf47; and for the non-HDLC:HDLC ratio, rs6589566 near APOA5. Five of these six variants are known to be associated with TG, LDLC, and/or HDLC, but rs17445774 was newly identified to be involved in lipid level changes in this study. Constitutional subgroup analysis revealed effects of variants associated with log[TG]:HDLC and non-HDLC:HDLC ratios in both the Tae-Eum and non-Tae-Eum types, whereas the effect of the LDLC:HDLC ratio-associated variants remained only in the Tae-Eum type. In conclusion, we identified three log[TG]:HDLC ratio-associated variants, two LDLC:HDLC ratio-associated variants, and one non-HDLC:HDLC-associated variant in Koreans and the constitutional subgroups.
Melloul, Emmanuel; Denys, Alban; Demartines, Nicolas
2015-09-01
During the last decade, the management of blunt hepatic injury has considerably changed. Three options are available as follows: nonoperative management (NOM), transarterial embolization (TAE), and surgery. We aimed to evaluate in a systematic review the current practice and outcomes in the management of Grade III to V blunt hepatic injury. The MEDLINE database was searched using PubMed to identify English-language citations published after 2000 using the key words blunt, hepatic injury, severe, and grade III to V in different combinations. Liver injury was graded according to the American Association for the Surgery of Trauma classification on computed tomography (CT). Primary outcome analyzed was success rate in intention to treat. Critical appraisal of the literature was performed using the validated National Institute for Health and Care Excellence "Quality Assessment for Case Series" system. Twelve articles were selected for critical appraisal (n = 4,946 patients). The median quality score of articles was 4 of 8 (range, 2-6). Overall, the median Injury Severity Score (ISS) at admission was 26 (range, 0.6-75). A median of 66% (range, 0-100%) of patients was managed with NOM, with a success rate of 94% (range, 86-100%). TAE was used in only 3% of cases (range, 0-72%) owing to contrast extravasation on CT with a success rate of 93% (range, 81-100%); however, 9% to 30% of patients required a laparotomy. Thirty-one percent (range, 17-100%) of patients were managed with surgery owing to hemodynamic instability in most cases, with 12% to 28% requiring secondary TAE to control recurrent hepatic bleeding. Mortality was 5% (range, 0-8%) after NOM and 51% (range, 30-68%) after surgery. NOM of Grade III to V blunt hepatic injury is the first treatment option to manage hemodynamically stable patients. TAE and surgery are considered in a highly selective group of patients with contrast extravasation on CT or shock at admission, respectively. Additional standardization of the reports is necessary to allow accurate comparisons of the various management strategies. Systematic review, level IV.
Kim, Taehyeung; Park, Ah Yeon; Baek, Younghwa
2017-01-01
Circulating lipid ratios are considered predictors of cardiovascular risks and metabolic syndrome, which cause coronary heart diseases. One constitutional type of Korean medicine prone to weight accumulation, the Tae-Eum type, predisposes the consumers to metabolic syndrome, hypertension, diabetes mellitus, etc. Here, we aimed to identify genetic variants for lipid ratios using a genome-wide association study (GWAS) and followed replication analysis in Koreans and constitutional subgroups. GWASs in 5,292 individuals of the Korean Genome and Epidemiology Study and replication analyses in 2,567 subjects of the Korea medicine Data Center were performed to identify genetic variants associated with triglyceride (TG) to HDL cholesterol (HDLC), LDL cholesterol (LDLC) to HDLC, and non-HDLC to HDLC ratios. For subgroup analysis, a computer-based constitution analysis tool was used to categorize the constitutional types of the subjects. In the discovery stage, seven variants in four loci, three variants in three loci, and two variants in one locus were associated with the ratios of log-transformed TG:HDLC (log[TG]:HDLC), LDLC:HDLC, and non-HDLC:HDLC, respectively. The associations of the GWAS variants with lipid ratios were replicated in the validation stage: for the log[TG]:HDLC ratio, rs6589566 near APOA5 and rs4244457 and rs6586891 near LPL; for the LDLC:HDLC ratio, rs4420638 near APOC1 and rs17445774 near C2orf47; and for the non-HDLC:HDLC ratio, rs6589566 near APOA5. Five of these six variants are known to be associated with TG, LDLC, and/or HDLC, but rs17445774 was newly identified to be involved in lipid level changes in this study. Constitutional subgroup analysis revealed effects of variants associated with log[TG]:HDLC and non-HDLC:HDLC ratios in both the Tae-Eum and non-Tae-Eum types, whereas the effect of the LDLC:HDLC ratio-associated variants remained only in the Tae-Eum type. In conclusion, we identified three log[TG]:HDLC ratio-associated variants, two LDLC:HDLC ratio-associated variants, and one non-HDLC:HDLC-associated variant in Koreans and the constitutional subgroups. PMID:28046027
Image processing and products for the Magellan mission to Venus
NASA Technical Reports Server (NTRS)
Clark, Jerry; Alexander, Doug; Andres, Paul; Lewicki, Scott; Mcauley, Myche
1992-01-01
The Magellan mission to Venus is providing planetary scientists with massive amounts of new data about the surface geology of Venus. Digital image processing is an integral part of the ground data system that provides data products to the investigators. The mosaicking of synthetic aperture radar (SAR) image data from the spacecraft is being performed at JPL's Multimission Image Processing Laboratory (MIPL). MIPL hosts and supports the Image Data Processing Subsystem (IDPS), which was developed in a VAXcluster environment of hardware and software that includes optical disk jukeboxes and the TAE-VICAR (Transportable Applications Executive-Video Image Communication and Retrieval) system. The IDPS is being used by processing analysts of the Image Data Processing Team to produce the Magellan image data products. Various aspects of the image processing procedure are discussed.
Investigations on high speed machining of EN-353 steel alloy under different machining environments
NASA Astrophysics Data System (ADS)
Venkata Vishnu, A.; Jamaleswara Kumar, P.
2018-03-01
The addition of Nano Particles into conventional cutting fluids enhances its cooling capabilities; in the present paper an attempt is made by adding nano sized particles into conventional cutting fluids. Taguchi Robust Design Methodology is employed in order to study the performance characteristics of different turning parameters i.e. cutting speed, feed rate, depth of cut and type of tool under different machining environments i.e. dry machining, machining with lubricant - SAE 40 and machining with mixture of nano sized particles of Boric acid and base fluid SAE 40. A series of turning operations were performed using L27 (3)13 orthogonal array, considering high cutting speeds and the other machining parameters to measure hardness. The results are compared among the different machining environments, and it is concluded that there is considerable improvement in the machining performance using lubricant SAE 40 and mixture of SAE 40 + boric acid compared with dry machining. The ANOVA suggests that the selected parameters and the interactions are significant and cutting speed has most significant effect on hardness.
NASA Astrophysics Data System (ADS)
Sharif, Safian; Sadiq, Ibrahim Ogu; Suhaimi, Mohd Azlan; Rahim, Shayfull Zamree Abd
2017-09-01
Pollution related activities in addition to handling cost of conventional cutting fluid application in metal cutting industry has generated a lot of concern over time. The desire for a green machining environment which will preserve the environment through reduction or elimination of machining related pollution, reduction in oil consumption and safety of the machine operators without compromising an efficient machining process led to search for alternatives to conventional cutting fluid. Amongst the alternatives of dry machining, cryogenic cooling, high pressure cooling, near dry or minimum quantity lubrication (MQL), MQL have shown remarkable performance in terms of cost, machining output, safety of environment and machine operators. However, the MQL under aggressive machining or very high speed machining pose certain restriction as the lubrication media cannot perform efficiently at elevated temperature. In compensating for the shortcomings of MQL technique, high thermal conductivity nanoparticles are introduced in cutting fluids for use in the MQL lubrication process. They have indicated enhanced performance of machining process and significant reduction of loads on the environment. The present work is aimed at evaluating the application and performance of nanofluid in metal cutting process through MQL lubrication technique highlighting their impacts and prospects as lubrication strategy in metal cutting process for sustainable green manufacturing. Enhanced performance of vegetable oil based nanofluids over mineral oil-based nanofluids have been reported and thus highlighted.
Direct Tumor Embolization of Sinonasal Unclassified Spindle Cell Sarcoma with Onyx.
Kansal, Ankit; Srinet, Prateek; Manes, Richard Peter
2016-07-01
To evaluate the use of a new tumor embolization agent, Onyx (Covidien, Dublin, Ireland), for the use of intraoperative embolization of a sinonasal unclassified spindle cell sarcoma. A 45-year-old female patient presented to the rhinology clinic with a nasal mass. A biopsy revealed a highly vascular mass consistent with a sinonasal unclassified spindle cell sarcoma. Secondary to its extensive vascularity, the patient underwent preoperative transarterial embolization (TAE) before definitive resection. Due to complex vascular anatomy including feeding vessels emanating from intracranial circulation, incomplete embolization was achieved. Subsequently, intraoperative embolization with Onyx at the time of resection was performed. Intraoperative Onyx use resulted in almost complete devascularization of the tumor with decreased risk of intracranial embolization. Intraoperative embolization with Onyx after an incomplete TAE can be a safe and effective method of achieving near-total embolization of sinonasal tumors.
Fully-kinetic Ion Simulation of Global Electrostatic Turbulent Transport in C-2U
NASA Astrophysics Data System (ADS)
Fulton, Daniel; Lau, Calvin; Bao, Jian; Lin, Zhihong; Tajima, Toshiki; TAE Team
2017-10-01
Understanding the nature of particle and energy transport in field-reversed configuration (FRC) plasmas is a crucial step towards an FRC-based fusion reactor. The C-2U device at Tri Alpha Energy (TAE) achieved macroscopically stable plasmas and electron energy confinement time which scaled favorably with electron temperature. This success led to experimental and theoretical investigation of turbulence in C-2U, including gyrokinetic ion simulations with the Gyrokinetic Toroidal Code (GTC). A primary objective of TAE's new C-2W device is to explore transport scaling in an extended parameter regime. In concert with the C-2W experimental campaign, numerical efforts have also been extended in A New Code (ANC) to use fully-kinetic (FK) ions and a Vlasov-Poisson field solver. Global FK ion simulations are presented. Future code development is also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Z.; Nazikian, R.; Fu, G.Y.
1997-02-01
Alpha-driven toroidal Alfven eigenmodes (TAEs) are observed as predicted by theory in the post neutral beam phase in high central q (safety factor) deuterium-tritium (D-T) plasmas in the Tokamak Fusion Test Reactor (TFTR). The mode location, poloidal structure and the importance of q profile for TAE instability are discussed. So far no alpha particle loss due to these modes was detected due to the small mode amplitude. However, alpha loss induced by kinetic ballooning modes (KBMs) was observed in high confinement D-T discharges. Particle orbit simulation demonstrates that the wave-particle resonant interaction can explain the observed correlation between the increasemore » in alpha loss and appearance of multiple high-n (n {ge} 6, n is the toroidal mode number) modes.« less
Mutation-Independent Activation of the Anaplastic Lymphoma Kinase in Neuroblastoma.
Regairaz, Marie; Munier, Fabienne; Sartelet, Hervé; Castaing, Marine; Marty, Virginie; Renauleaud, Céline; Doux, Camille; Delbé, Jean; Courty, José; Fabre, Monique; Ohta, Shigeru; Vielh, Philippe; Michiels, Stefan; Valteau-Couanet, Dominique; Vassal, Gilles
2016-02-01
Activating mutations of anaplastic lymphoma kinase (ALK) have been identified as important players in neuroblastoma development. Our goal was to evaluate the significance of overall ALK activation in neuroblastoma. Expression of phosphorylated ALK, ALK, and its putative ligands, pleiotrophin and midkine, was screened in 289 neuroblastomas and 56 paired normal tissues. ALK was expressed in 99% of tumors and phosphorylated in 48% of cases. Pleiotrophin and midkine were expressed in 58% and 79% of tumors, respectively. ALK activation was significantly higher in tumors than in paired normal tissues, together with ALK and midkine expression. ALK activation was largely independent of mutations and correlated with midkine expression in tumors. ALK activation in tumors was associated with favorable features, including a younger age at diagnosis, hyperdiploidy, and detection by mass screening. Antitumor activity of the ALK inhibitor TAE684 was evaluated in wild-type or mutated ALK neuroblastoma cell lines and xenografts. TAE684 was cytotoxic in vitro in all cell lines, especially those harboring an ALK mutation. TAE684 efficiently inhibited ALK phosphorylation in vivo in both F1174I and R1275Q xenografts but demonstrated antitumor activity only against the R1275Q xenograft. In conclusion, ALK activation occurs frequently during neuroblastoma oncogenesis, mainly through mutation-independent mechanisms. However, ALK activation is not associated with a poor outcome and is not always a driver of cell proliferation and/or survival in neuroblastoma. Copyright © 2016 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
1.5D quasilinear model and its application on beams interacting with Alfvén eigenmodes in DIII-D
NASA Astrophysics Data System (ADS)
Ghantous, K.; Gorelenkov, N. N.; Berk, H. L.; Heidbrink, W. W.; Van Zeeland, M. A.
2012-09-01
We propose a model, denoted here by 1.5D, to study energetic particle (EP) interaction with toroidal Alfvenic eigenmodes (TAE) in the case where the local EP drive for TAE exceeds the stability limit. Based on quasilinear theory, the proposed 1.5D model assumes that the particles diffuse in phase space, flattening the pressure profile until its gradient reaches a critical value where the modes stabilize. Using local theories and NOVA-K simulations of TAE damping and growth rates, the 1.5D model calculates the critical gradient and reconstructs the relaxed EP pressure profile. Local theory is improved from previous study by including more sophisticated damping and drive mechanisms such as the numerical computation of the effect of the EP finite orbit width on the growth rate. The 1.5D model is applied on the well-diagnosed DIII-D discharges #142111 [M. A. Van Zeeland et al., Phys. Plasmas 18, 135001 (2011)] and #127112 [W. W. Heidbrink et al., Nucl. Fusion. 48, 084001 (2008)]. We achieved a very satisfactory agreement with the experimental results on the EP pressure profiles redistribution and measured losses. This agreement of the 1.5D model with experimental results allows the use of this code as a guide for ITER plasma operation where it is desired to have no more than 5% loss of fusion alpha particles as limited by the design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Picel, Andrew C., E-mail: apicel@ucsd.edu; Koo, Sonya J.; Roberts, Anne C.
PurposeThe purpose of the study was to evaluate the technique and outcomes of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate (NBCA) for the treatment of acquired uterine arteriovenous malformations (AVMs).Materials and methodsA retrospective review identified five women treated for suspected acquired uterine AVMs with TAE at our institution. Four women (80 %) presented with heavy or intermittent vaginal bleeding after obstetric manipulation. One woman (20 %) was treated for an incidental AVM discovered on ultrasound after an uncomplicated cesarean section. Three women underwent one embolization procedure and two women required two procedures. Embolization material included NBCA in six procedures (80 %) and gelatinmore » sponge in one procedure (20 %).ResultsEmbolization resulted in angiographic stasis of flow in all seven procedures. Four women (80 %) presented with vaginal bleeding which was improved after treatment. One woman returned 24 days after unilateral embolization with recurrent bleeding, which resolved after retreatment. One woman underwent two treatments for an asymptomatic lesion identified on ultrasound. There were no major complications. Three women (60 %) experienced mild postembolization pelvic pain that was controlled with non-steroidal anti-inflammatory drugs. Three women (60 %) had pregnancies and deliveries after embolization.ConclusionsTAE is a safe alternative to surgical therapy for acquired uterine AVMs with the potential to maintain fertility. Experience from this case series suggests that NBCA provides predictable and effective occlusion.« less
Transferred interbacterial antagonism genes augment eukaryotic innate immune function.
Chou, Seemay; Daugherty, Matthew D; Peterson, S Brook; Biboy, Jacob; Yang, Youyun; Jutras, Brandon L; Fritz-Laylin, Lillian K; Ferrin, Michael A; Harding, Brittany N; Jacobs-Wagner, Christine; Yang, X Frank; Vollmer, Waldemar; Malik, Harmit S; Mougous, Joseph D
2015-02-05
Horizontal gene transfer allows organisms to rapidly acquire adaptive traits. Although documented instances of horizontal gene transfer from bacteria to eukaryotes remain rare, bacteria represent a rich source of new functions potentially available for co-option. One benefit that genes of bacterial origin could provide to eukaryotes is the capacity to produce antibacterials, which have evolved in prokaryotes as the result of eons of interbacterial competition. The type VI secretion amidase effector (Tae) proteins are potent bacteriocidal enzymes that degrade the cell wall when delivered into competing bacterial cells by the type VI secretion system. Here we show that tae genes have been transferred to eukaryotes on at least six occasions, and that the resulting domesticated amidase effector (dae) genes have been preserved for hundreds of millions of years through purifying selection. We show that the dae genes acquired eukaryotic secretion signals, are expressed within recipient organisms, and encode active antibacterial toxins that possess substrate specificity matching extant Tae proteins of the same lineage. Finally, we show that a dae gene in the deer tick Ixodes scapularis limits proliferation of Borrelia burgdorferi, the aetiologic agent of Lyme disease. Our work demonstrates that a family of horizontally acquired toxins honed to mediate interbacterial antagonism confers previously undescribed antibacterial capacity to eukaryotes. We speculate that the selective pressure imposed by competition between bacteria has produced a reservoir of genes encoding diverse antimicrobial functions that are tailored for co-option by eukaryotic innate immune systems.
NASA Astrophysics Data System (ADS)
Yang, Xiaokang; Petrov, Yuri; Ceccherini, Francesco; Koehn, Alf; Galeotti, Laura; Dettrick, Sean; Binderbauer, Michl
2017-10-01
Numerous efforts have been made at Tri-Alpha Energy (TAE) to theoretically explore the physics of microwave electron heating in field-reversed configuration (FRC) plasmas. For the fixed 2D profiles of plasma density and temperature for both electrons and thermal ions and equilibrium field of the C-2U machine, simulations with GENRAY-C ray-tracing code have been conducted for the ratios of ω/ωci[D] in the range of 6 - 20. Launch angles and antenna radial and axial positions have been optimized in order to simultaneously achieve good wave penetration into the core of FRC plasmas and efficient power damping on electrons. It is found that in an optimal regime, single pass absorption efficiency is 100% and most of the power is deposited inside the separatrix of FRC plasmas, with power damping efficiency of about 72% on electrons and less than 19% on ions. Calculations have clearly demonstrated that substantial power absorption on electrons is mainly attributed to high beta enhancement of magnetic pumping; complete power damping occurs before Landau damping has a significant effect on power absorption.
NASA Astrophysics Data System (ADS)
Miao, Yongchun; Kang, Rongxue; Chen, Xuefeng
2017-12-01
In recent years, with the gradual extension of reliability research, the study of production system reliability has become the hot topic in various industries. Man-machine-environment system is a complex system composed of human factors, machinery equipment and environment. The reliability of individual factor must be analyzed in order to gradually transit to the research of three-factor reliability. Meanwhile, the dynamic relationship among man-machine-environment should be considered to establish an effective blurry evaluation mechanism to truly and effectively analyze the reliability of such systems. In this paper, based on the system engineering, fuzzy theory, reliability theory, human error, environmental impact and machinery equipment failure theory, the reliabilities of human factor, machinery equipment and environment of some chemical production system were studied by the method of fuzzy evaluation. At last, the reliability of man-machine-environment system was calculated to obtain the weighted result, which indicated that the reliability value of this chemical production system was 86.29. Through the given evaluation domain it can be seen that the reliability of man-machine-environment integrated system is in a good status, and the effective measures for further improvement were proposed according to the fuzzy calculation results.
Sasang Constitution as a Risk Factor for Diabetes Mellitus: A Cross-Sectional Study
Lee, Tae-Gyu; Koh, Byunghee
2009-01-01
Sasang Constitutional Medicine, which is a branch of traditional Korean medicine, states that medications for diabetes should be individualized according to the patient's individual constitution. However, the effect of constitution on diabetes has not been evaluated to date. Therefore, this study was conducted to determine if constitution is an independent risk factor for diabetes by comparing the prevalence and odds ratios (ORs) of the disease according to constitution. The medical records of 1443 adults who had been examined and classified based on their constitution at Kyung Hee University Hospital in Seoul, Korea were reviewed. A chi-squared test and Fisher's exact test were used to compare the prevalence of diabetes according to constitution, and multiple logistic regression was used to calculate the ORs for diabetes. The prevalence of diabetes differed significantly according to constitution (χ2 = 36.20, df = 2, P < 0.001). Specifically, the prevalence of the disease was higher in Tae-eumin (11.4%) individuals than in Soyangin (5.0%) or Soeumin (1.7%) individuals. In addition, multiple logistic regression revealed that Tae-eumin individuals had a greater risk for diabetes than Soeumin individuals. When compared to Soeumin individuals, the adjusted ORs were 2.01 (95% CI 0.77–5.26) for Soyangin individuals and 3.96 (95% CI 1.48–10.60) for Tae-eumin individuals. These results show that constitution has a significant and independent association with diabetes, which suggests that constitution is an independent risk factor for diabetes that should be considered when attempting to detect and prevent the disease. PMID:19745018
Modeling of potential TAE-induced beam ion loss from NSTX-U plasmas
NASA Astrophysics Data System (ADS)
Darrow, Douglass; Fredrickson, Eric; Podesta, Mario; White, Roscoe; Liu, Deyong
2015-11-01
NSTX-U will add three additional neutral beam sources, whose tangency radii of 1.1, 1.2, and 1.3 m, are significantly larger than the 0.5, 0.6, and 0.7 m tangency radii of the neutral beams previously used in NSTX. These latter beams will also be used in NSTX-U. Here, we attempt to formulate an estimate of the propensity of the beam ions from all the various sources to be lost under a range of NSTX-U plasma conditions. This estimation is based upon TRANSP calculations of beam ion deposition in phase space, and the location of the FLR-corrected loss boundary in that phase space. Since TAEs were a prominent driver of beam ion loss in NSTX, we incorporate their effects through the following process: NOVA modeling of TAEs in the anticipated NSTX-U plasma conditions gives the mode numbers, frequencies, and mode structures that are likely to occur. Using this information as inputs to the guiding center ORBIT code, it is possible to find resonant surfaces in the same phase space along which beam ions would be able to diffuse under the influence of the modes. The degree to which these resonant surfaces intersect both the beam deposition volume and the orbit loss boundary should then give a sense of the propensity of that beam population to be lost from the plasma. Work supported by US DOE contracts DE-AC0209CH11466, DE-FG02-06ER54867, and DE-FG03-02ER54681.
Inheritance of thelytoky in the honey bee Apis mellifera capensis
Chapman, N C; Beekman, M; Allsopp, M H; Rinderer, T E; Lim, J; Oxley, P R; Oldroyd, B P
2015-01-01
Asexual reproduction via thelytokous parthenogenesis is widespread in the Hymenoptera, but its genetic underpinnings have been described only twice. In the wasp Lysiphlebus fabarum and the Cape honey bee Apis mellifera capensis the origin of thelytoky have each been traced to a single recessive locus. In the Cape honey bee it has been argued that thelytoky (th) controls the thelytoky phenotype and that a deletion of 9 bp in the flanking intron downstream of exon 5 (tae) of the gemini gene switches parthenogenesis from arrhenotoky to thelytoky. To further explore the mode of inheritance of thelytoky, we generated reciprocal backcrosses between thelytokous A. m. capensis and the arrhenotokous A. m. scutellata. Ten genetic markers were used to identify 108 thelytokously produced offspring and 225 arrhenotokously produced offspring from 14 colonies. Patterns of appearance of thelytokous parthenogenesis were inconsistent with a single locus, either th or tae, controlling thelytoky. We further show that the 9 bp deletion is present in the arrhenotokous A. m. scutellata population in South Africa, in A. m. intermissa in Morocco and in Africanized bees from Brazil and Texas, USA, where thelytoky has not been reported. Thus the 9 bp deletion cannot be the cause of thelytoky. Further, we found two novel tae alleles. One contains the previously described 9 bp deletion and an additional deletion of 7 bp nearby. The second carries a single base insertion with respect to the wild type. Our data are consistent with the putative th locus increasing reproductive capacity. PMID:25585920
NASA Astrophysics Data System (ADS)
Van Zeeland, M. A.; Heidbrink, W. W.; Sharapov, S. E.; Spong, D.; Cappa, A.; Chen, Xi; Collins, C.; García-Muñoz, M.; Gorelenkov, N. N.; Kramer, G. J.; Lauber, P.; Lin, Z.; Petty, C.
2016-11-01
A recent DIII-D experiment investigating the impact of electron cyclotron heating (ECH) on neutral beam driven reversed shear Alfvén eigenmode (RSAE) activity is presented. The experiment includes variations of ECH injection location and timing, current ramp rate, beam injection geometry (on/off-axis), and neutral beam power. Essentially all variations carried out in this experiment were observed to change the impact of ECH on AE activity significantly. In some cases, RSAEs were observed to be enhanced with ECH near the off-axis minimum in magnetic safety factor ({{q}\\min} ), in contrast to the original DIII-D experiments where the modes were absent when ECH was deposited near {{q}\\min} . It is found that during intervals when the geodesic acoustic mode (GAM) frequency at {{q}\\min} is elevated and the calculated RSAE minimum frequency, including contributions from thermal plasma gradients, is very near or above the nominal TAE frequency (f TAE), RSAE activity is not observed or RSAEs with a much reduced frequency sweep range are found. This condition is primarily brought about by ECH modification of the local electron temperature (T e) which can raise both the local T e at {{q}\\min} as well as its gradient. A q-evolution model that incorporates this reduction in RSAE frequency sweep range is in agreement with the observed spectra and appears to capture the relative balance of TAE or RSAE-like modes throughout the current ramp phase of over 38 DIII-D discharges. Detailed ideal MHD calculations using the NOVA code show both modification of plasma pressure and pressure gradient at {{q}\\min} play an important role in modifying the RSAE activity. Analysis of the ECH injection near the {{q}\\min} case where no frequency sweeping RSAEs are observed shows the typical RSAE is no longer an eigenmode of the system. What remains is an eigenmode with poloidal harmonic content reminiscent of the standard RSAE, but absent of the typical frequency sweeping behavior. The remaining eigenmode is also often strongly coupled to gap TAEs. Analysis with the non-perturbative gyro fluid code TAEFL confirms this change in RSAE activity and also shows a large drop in the resultant mode growth rates.
Van Zeeland, M. A.; Heidbrink, W. W.; Sharapov, S. E.; ...
2016-07-22
Here, a recent DIII-D experiment investigating the impact of electron cyclotron heating (ECH) on neutral beam driven reversed shear Alfvén eigenmode (RSAE) activity is presented. The experiment includes variations of ECH injection location and timing, current ramp rate, beam injection geometry (on/off-axis), and neutral beam power. Essentially all variations carried out in this experiment were observed to change the impact of ECH on AE activity significantly. In some cases, RSAEs were observed to be enhanced with ECH near the off-axis minimum in magnetic safety factor (more » $${{q}_{\\min}}$$ ), in contrast to the original DIII-D experiments where the modes were absent when ECH was deposited near $${{q}_{\\min}}$$ . It is found that during intervals when the geodesic acoustic mode (GAM) frequency at $${{q}_{\\min}}$$ is elevated and the calculated RSAE minimum frequency, including contributions from thermal plasma gradients, is very near or above the nominal TAE frequency (f TAE), RSAE activity is not observed or RSAEs with a much reduced frequency sweep range are found. This condition is primarily brought about by ECH modification of the local electron temperature (T e) which can raise both the local T e at $${{q}_{\\min}}$$ as well as its gradient. A q-evolution model that incorporates this reduction in RSAE frequency sweep range is in agreement with the observed spectra and appears to capture the relative balance of TAE or RSAE-like modes throughout the current ramp phase of over 38 DIII-D discharges. Detailed ideal MHD calculations using the NOVA code show both modification of plasma pressure and pressure gradient at $${{q}_{\\min}}$$ play an important role in modifying the RSAE activity. Analysis of the ECH injection near the $${{q}_{\\min}}$$ case where no frequency sweeping RSAEs are observed shows the typical RSAE is no longer an eigenmode of the system. What remains is an eigenmode with poloidal harmonic content reminiscent of the standard RSAE, but absent of the typical frequency sweeping behavior. The remaining eigenmode is also often strongly coupled to gap TAEs. Analysis with the non-perturbative gyro fluid code TAEFL confirms this change in RSAE activity and also shows a large drop in the resultant mode growth rates.« less
Pilot performance and workload using simulated GPS track angle error displays
DOT National Transportation Integrated Search
1995-01-01
The effect on simulated GPS instrument approach performance and workload resulting from the addition of Track Angle Error (TAE) information to cockpit RNAV receiver displays in explicit analog form was studied experimentally (S display formats, 6 pil...
77 FR 69916 - Aviation Rulemaking Advisory Committee; Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-21
... Expectations 3. Recommendation Reports a. Rulemaking Prioritization Working Group (RPWG) Recommendation Report (ARAC) b. Avionics Systems Harmonization Working Group--Low Speed Alerting, Phase 2 Recommendation Report (TAE) 4. Status Reports From Active Working Groups a. Airman Testing Standards and Training...
The Use of Analog Track Angle Error Display for Improving Simulated GPS Approach Performance
DOT National Transportation Integrated Search
1995-08-01
The effect of adding track angle error (TAE) information to general aviation aircraft cockpit displays used for GPS : nonprecision instrument approaches was studied experimentally. Six pilots flew 120 approaches in a Frasca 242 light : twin aircraft ...
Meteorological Instruction Software
NASA Technical Reports Server (NTRS)
1990-01-01
At Florida State University and the Naval Postgraduate School, meteorology students have the opportunity to apply theoretical studies to current weather phenomena, even prepare forecasts and see how their predictions stand up utilizing GEMPAK. GEMPAK can display data quickly in both conventional and non-traditional ways, allowing students to view multiple perspectives of the complex three-dimensional atmospheric structure. With GEMPAK, mathematical equations come alive as students do homework and laboratory assignments on the weather events happening around them. Since GEMPAK provides data on a 'today' basis, each homework assignment is new. At the Naval Postgraduate School, students are now using electronically-managed environmental data in the classroom. The School's Departments of Meteorology and Oceanography have developed the Interactive Digital Environment Analysis (IDEA) Laboratory. GEMPAK is the IDEA Lab's general purpose display package; the IDEA image processing package is a modified version of NASA's Device Management System. Bringing the graphic and image processing packages together is NASA's product, the Transportable Application Executive (TAE).
NASA Astrophysics Data System (ADS)
Desai, A. B.; Desai, K. P.; Naik, H. B.; Atrey, M. D.
2017-02-01
Thermoacoustic engines (TAEs) are devices which convert heat energy into useful acoustic work whereas thermoacoustic refrigerators (TARs) convert acoustic work into temperature gradient. These devices work without any moving component. Study presented here comprises of a combination system i.e. thermoacoustic engine driven thermoacoustic refrigerator (TADTAR). This system has no moving component and hence it is easy to fabricate but at the same time it is very challenging to design and construct optimized system with comparable performance. The work presented here aims to apply optimization technique to TADTAR in the form of response surface methodology (RSM). Significance of stack position and stack length for engine stack, stack position and stack length for refrigerator stack are investigated in current work. Results from RSM are compared with results from simulations using Design Environment for Low-amplitude Thermoacoustic Energy conversion (DeltaEC) for compliance.
Weykamp, Cas; John, Garry; Gillery, Philippe; English, Emma; Ji, Linong; Lenters-Westra, Erna; Little, Randie R.; Roglic, Gojka; Sacks, David B.; Takei, Izumi
2016-01-01
Background A major objective of the IFCC Task Force on implementation of HbA1c standardization is to develop a model to define quality targets for HbA1c. Methods Two generic models, the Biological Variation and Sigma-metrics model, are investigated. Variables in the models were selected for HbA1c and data of EQA/PT programs were used to evaluate the suitability of the models to set and evaluate quality targets within and between laboratories. Results In the biological variation model 48% of individual laboratories and none of the 26 instrument groups met the minimum performance criterion. In the Sigma-metrics model, with a total allowable error (TAE) set at 5 mmol/mol (0.46% NGSP) 77% of the individual laboratories and 12 of 26 instrument groups met the 2 sigma criterion. Conclusion The Biological Variation and Sigma-metrics model were demonstrated to be suitable for setting and evaluating quality targets within and between laboratories. The Sigma-metrics model is more flexible as both the TAE and the risk of failure can be adjusted to requirements related to e.g. use for diagnosis/monitoring or requirements of (inter)national authorities. With the aim of reaching international consensus on advice regarding quality targets for HbA1c, the Task Force suggests the Sigma-metrics model as the model of choice with default values of 5 mmol/mol (0.46%) for TAE, and risk levels of 2 and 4 sigma for routine laboratories and laboratories performing clinical trials, respectively. These goals should serve as a starting point for discussion with international stakeholders in the field of diabetes. PMID:25737535
Phase space effects on fast ion transport modeling in tokamaks
NASA Astrophysics Data System (ADS)
Podesta, Mario
2015-11-01
Simulations of burning plasmas require a consistent treatment of energetic particles (EP), possibly including the effects of instabilities. Reduced EP transport models are emerging as an effective tool to account for those effects in long time-scale simulations. Available models essentially differ for the main transport drive, which is associated to gradients in real or phase space. It is crucial to assess to what extent those different assumptions affect computed quantities such as EP profile, Neutral Beam (NB) driven current and energy/momentum transfer to the thermal populations. These issues are investigated through a kick model, which includes modifications of the EP distribution by instabilities in real and velocity space. TRANSP simulations including the kick model are applied to NB-heated NSTX discharges featuring unstable toroidal Alfvén eigenmodes (TAEs). Results show that TAEs mainly affect fast ions with large parallel velocity, i.e. the most effective for NB current drive. Other portions of the EP distribution are nearly unperturbed. Core NB driven current decreases by 10-30%, with even larger relative changes toward the plasma edge. When TAEs evolve in so-called avalanches, the model reproduces measured drops of ~ 10% in the neutron rate. Consistently with previous results, the drop is caused by both EP energy loss and EP redistribution. These results are compared to those from a simple diffusive model and a ``critical gradient'' model, which postulates radial EP gradient as the only transport drive. The importance of EP velocity space modifications is discussed in terms of accuracy of the predictions, with emphasis on Neutral Beam driven current. Work supported by U.S. DOE Contract DE-AC02-09CH11466.
Tanizaki, Junko; Okamoto, Isamu; Okabe, Takafumi; Sakai, Kazuko; Tanaka, Kaoru; Hayashi, Hidetoshi; Kaneda, Hiroyasu; Takezawa, Ken; Kuwata, Kiyoko; Yamaguchi, Haruka; Hatashita, Erina; Nishio, Kazuto; Nakagawa, Kazuhiko
2012-11-15
Anaplastic lymphoma kinase (ALK) tyrosine kinase inhibitors (TKI) such as crizotinib show marked efficacy in patients with non-small cell lung cancer positive for the echinoderm microtubule-associated protein-like 4 (EML4)-ALK fusion protein. However, acquired resistance to these agents has already been described in treated patients, and the mechanisms of such resistance remain largely unknown. We established lines of EML4-ALK-positive H3122 lung cancer cells that are resistant to the ALK inhibitor TAE684 (H3122/TR cells) and investigated their resistance mechanism with the use of immunoblot analysis, ELISA, reverse transcription and real-time PCR analysis, and an annexin V binding assay. We isolated EML4-ALK-positive lung cancer cells (K-3) from a patient who developed resistance to crizotinib and investigated their characteristics. The expression of EML4-ALK was reduced at the transcriptional level, whereas phosphorylation of epidermal growth factor receptor (EGFR), HER2, and HER3 was upregulated, in H3122/TR cells compared with those in H3122 cells. This activation of HER family proteins was accompanied by increased secretion of EGF. Treatment with an EGFR-TKI induced apoptosis in H3122/TR cells, but not in H3122 cells. The TAE684-induced inhibition of extracellular signal-regulated kinase (ERK) and STAT3 phosphorylation observed in parental cells was prevented by exposure of these cells to exogenous EGF, resulting in a reduced sensitivity of cell growth to TAE684. K-3 cells also manifested HER family activation accompanied by increased EGF secretion. EGF-mediated activation of HER family signaling is associated with ALK-TKI resistance in lung cancer positive for EML4-ALK. ©2012 AACR.
Nakamoto, Y; Mizukoshi, E; Kitahara, M; Arihara, F; Sakai, Y; Kakinoki, K; Fujita, Y; Marukawa, Y; Arai, K; Yamashita, T; Mukaida, N; Matsushima, K; Matsui, O; Kaneko, S
2011-01-01
Despite curative locoregional treatments for hepatocellular carcinoma (HCC), tumour recurrence rates remain high. The current study was designed to assess the safety and bioactivity of infusion of dendritic cells (DCs) stimulated with OK432, a streptococcus-derived anti-cancer immunotherapeutic agent, into tumour tissues following transcatheter hepatic arterial embolization (TAE) treatment in patients with HCC. DCs were derived from peripheral blood monocytes of patients with hepatitis C virus-related cirrhosis and HCC in the presence of interleukin (IL)-4 and granulocyte-macrophage colony-stimulating factor and stimulated with 0·1 KE/ml OK432 for 2 days. Thirteen patients were administered with 5 × 106 of DCs through arterial catheter during the procedures of TAE treatment on day 7. The immunomodulatory effects and clinical responses were evaluated in comparison with a group of 22 historical controls treated with TAE but without DC transfer. OK432 stimulation of immature DCs promoted their maturation towards cells with activated phenotypes, high expression of a homing receptor, fairly well-preserved phagocytic capacity, greatly enhanced cytokine production and effective tumoricidal activity. Administration of OK432-stimulated DCs to patients was found to be feasible and safe. Kaplan–Meier analysis revealed prolonged recurrence-free survival of patients treated in this manner compared with the historical controls (P = 0·046, log-rank test). The bioactivity of the transferred DCs was reflected in higher serum concentrations of the cytokines IL-9, IL-15 and tumour necrosis factor-α and the chemokines CCL4 and CCL11. Collectively, this study suggests that a DC-based, active immunotherapeutic strategy in combination with locoregional treatments exerts beneficial anti-tumour effects against liver cancer. PMID:21087443
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ikoma, Akira; Kawai, Nobuyuki; Sato, Morio, E-mail: morisato@wakayama-med.ac.jp
2010-10-15
This study was designed to assess the safety of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate-lipiodol (NBCA-Lp) for the large bowel and to investigate the vital response to NBCA-Lp in a swine model. In nine swine, nine arteries nourishing the colon were embolized with NBCA-Lp (1 ml of NBCA mixed with 4 ml of lipiodol): sigmoid-rectal branch artery in six swine, right colic branch artery in two, and middle colic branch artery in one. The amount of NBCA-Lp was 0.1-0.4 ml. Sacrifice was conducted 3 days after TAE to identify histological infarction. Classification was conducted retrospectively: group A, vasa rectamore » without NBCA-Lp embolization despite TAE; group B, three or fewer vasa recta with NBCA-Lp embolization; and group C, five or more vasa recta with NBCA-Lp embolization. In one swine in group A, no necrotic focus was observed. In group B, three of four swine experienced no ischemic damage. The remaining one swine experienced necrosis of mucosal and submucosal layers in one-fourth of the circumference. In group C, all four swine with marginal artery and five vasa recta or more embolized experienced total necrosis of mucosa, submucosa, and smooth muscle layers of the whole colonic circumference. Significant difference on the extent of ischemic damage was observed between groups B and C (P < 0.05). Microscopically, NBCA-Lp induced acute vasculitis. Embolization of three or fewer vasa recta with NBCA-Lp induced no ischemic damage or limited necrosis, whereas embolization of five or more vasa recta with NBCA-Lp induced extensive necrosis.« less
Safavi, Arash; Skarsgard, Erik D; Rhee, Peter; Zangbar, Bardiya; Kulvatunyou, Narong; Tang, Andrew; O'Keeffe, Terence; Friese, Randall S; Joseph, Bellal
2016-03-01
Nonoperative management of hemodynamically stable children with Solid Organ Injury (SOI) has become standard of care. The aim of this study is to identify differences in management of children with SOI treated at Adult Trauma Centers (ATC) versus Pediatric Trauma Centers (PTC). We hypothesized that patients treated at ATC would undergo more procedures than PTC. Patients younger than 18 years old with isolated SOI (spleen, liver, kidney) who were treated at level I-II ATC or PTC were identified from the 2011-2012 National Trauma Data Bank. The primary outcome measure was the incidence of operative management. Data was analyzed using multivariate logistic regression analysis. Procedures were defined as surgery or transarterial embolization (TAE). 6799 children with SOI (spleen: 2375, liver: 2867, kidney: 1557) were included. Spleen surgery was performed more frequently at ATC than PTC {101 (7.7%) vs. 52 (4.9%); P=0.007}. After adjusting for potential confounders (grade of injury, age, gender and injury severity score), admission at ATC was associated with higher odds of splenic surgery (OR: 1.5, 95% CI: 1.02-2.25; p=0.03). 11 and 8 children underwent kidney and liver operations respectively. TAE was performed in 17 patients with splenic, 34 with liver and 14 with kidney trauma. There was no practice variation between ATC and PTC regarding kidney and liver operations or TAE incidence. Operative management for SOI was more often performed at ATC. The presence of significant disparity in the management of children with splenic injuries justifies efforts to use these surgeries as a reported national quality indicator for trauma programs. Published by Elsevier Inc.
Shin, Seong Woo; Ghimeray, Amal Kumar; Park, Cheol Ho
2014-01-01
This study was carried out to investigate the total polyphenol (TP), total flavonoid (TF), antioxidative effect and allyl isothyocyanate (ITC) content in different organs of wasabi plant grown in an organic system. Invitro study of methanol and boiled water extracts of wasabi were conducted by analyzing the 1-1-diphenyl-2-picryl hydrozyl (DPPH) radial scavenging activity, metal chelating activity and total antioxidant capacity in a comparative manner. The result revealed that methanol extract showed higher TP in flower (3644 mg TAE/100 g dw), leaf (3201 mg TAE/100 g dw) and fruit (3025 mg TAE/100 g dw) as compared to the boiled water extract. Similarly, TF content was also higher in methanol extracts of flower (1152 mg QE/100 g dw) and leaf (325 mg QE/100 g dw), however, the other parts showed ignorable value. Results of antioxidant activity were found at different magnitude of potency. The methanol extract of different parts of wasabi exhibited higher activity in total antioxidant capacity and DPPH radical scavenging assay as compared to water extract. In metal chelating assay, the boiled water extracts of leaf showed higher (76.9%) activity, followed by fruit (68.8%) and flower (62.8%). Ally ITC detected by gas chromatography was present in all of the tissues of wasabi plant but the content was found to be varied in different tissues. Overall, this study will allow consumers and processors to understand the possibility for medical application of wasabi plant by knowing the level of total polyphenol distribution, Ally ITC content and antioxidant property distributed in different parts and tissues.Key words: Allyl ITC, antioxidant, flavonoid, polyphenol, Wasabi japonica.
Hagiwara, Akiyoshi; Tarui, Takehiko; Murata, Atsuo; Matsuda, Takeaki; Yamaguti, Yoshihiro; Shimazaki, Shuji
2005-07-01
The purpose of this study was to determine the association between bilomas and pseudoaneurysm complications after severe hepatic injury. Angiography was performed in patients with American Association for the Surgery of Trauma grade > or = III hepatic injury on contrast-enhanced computed tomographic scanning. When contrast extravasation was observed, transarterial embolization (TAE) was performed. After TAE, technetium-99m pyridoxyl-5-methyl-tryptophan cholescintigraphy was performed to detect the coexistence of bilomas. Follow-up angiography was performed when a biloma was detected. Eighty consecutive patients underwent angiography; after angiography, five patients died. The remaining 75 patients who underwent cholescintigraphy were included in this study. All 11 patients who had bilomas had angiographic evidence of contrast extravasation. The biloma frequency was higher in patients with grades IV and V injuries than in those with grade III injury (p = 0.024). Follow-up angiography revealed pseudoaneurysms in 7 of these 11 patients. All six patients in whom only gelatin sponge pledget injection was used to embolize had pseudoaneurysms. Among them, two patients had computed tomographic evidence of massive intra-abdominal fluid collection. In contrast, only one of five patients who received the combination of gelatin sponge pledget injection and stainless steel coils to permanently embolize injured arteries had a pseudoaneurysm. In this patient, the pseudoaneurysm was found in the peripheral part of the collateral vessels. All patients with pseudoaneurysms underwent repeat TAE and were discharged from the hospital uneventfully. In patients with high-grade hepatic injury and arterial bleeding who developed biloma, use of a gelatin sponge, an absorbable embolic material, is associated with a risk of pseudoaneurysm formation. Permanent arterial embolization using stainless steel coils is indicated to decrease this risk.
Langmuir probe diagnostic suite in the C-2 field-reversed configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roche, T., E-mail: troche@trialphaenergy.com; Armstrong, S.; Knapp, K.
2014-11-15
Several in situ probes have been designed and implemented into the diagnostic array of the C-2 field-reversed configuration (FRC) at Tri Alpha Energy [M. Tuszewski et al. (the TAE Team), Phys. Rev. Lett. 108, 255008 (2012)]. The probes are all variations on the traditional Langmuir probe. They include linear arrays of triple probes, linear arrays of single-tipped swept probes, a multi-faced Gundestrup probe, and an ion-sensitive probe. The probes vary from 5 to 7 mm diameter in size to minimize plasma perturbations. They also have boron nitride outer casings that prevent unwanted electrical breakdown and reduce the introduction of impurities.more » The probes are mounted on motorized linear-actuators allowing for programmatic scans of the various plasma parameters over the course of several shots. Each probe has a custom set of electronics that allows for measurement of the desired signals. High frequency ( > 5MHz) analog optical-isolators ensure that plasma parameters can be measured at sub-microsecond time scales while providing electrical isolation between machine and data acquisition systems. With these probes time-resolved plasma parameters (temperature, density, spatial potential, flow, and electric field) can be directly/locally measured in the FRC jet and edge/scrape-off layer.« less
Studies of Thickened Liquids and Miscellaneous Flame Thrower Problems
1945-10-23
34’ •’lllaa.._ • 1M ..... .,_, aad Ule ~7 tl ... pa .. 4 .. , .. on a 8ulell ella••l• ••• ••••bled. ftll• unl’ perro .... • ••’l•taeMrll~ ’Ita’ 1
Prevalence of Metabolic Syndrome according to Sasang Constitutional Medicine in Korean Subjects
Song, Kwang Hoon; Yu, Sung-Gon; Kim, Jong Yeol
2012-01-01
Metabolic syndrome (MS) is a complex disorder defined by a cluster of abdominal obesity, atherogenic dyslipidemia, hyperglycemia, and hypertension; the condition is recognized as a risk factor for diabetes and cardiovascular disease. This study assessed the effects of the Sasang constitution group (SCG) on the risk of MS in Korean subjects. We have analyzed 1,617 outpatients of Korean oriental medicine hospitals who were classified into three SCGs, So-Yang, So-Eum, and Tae-Eum. Significant differences were noted in the prevalence of MS and the frequencies of all MS risk factors among the three SCGs. The odds ratios for MS as determined via multiple logistic regression analysis were 2.004 for So-Yang and 4.521 for Tae-Eum compared with So-Eum. These results indicate that SCG may function as a significant risk factor of MS; comprehensive knowledge of Sasang constitutional medicine may prove helpful in predicting susceptibility and developing preventive care techniques for MS. PMID:22454673
Prevalence of Metabolic Syndrome according to Sasang Constitutional Medicine in Korean Subjects.
Song, Kwang Hoon; Yu, Sung-Gon; Kim, Jong Yeol
2012-01-01
Metabolic syndrome (MS) is a complex disorder defined by a cluster of abdominal obesity, atherogenic dyslipidemia, hyperglycemia, and hypertension; the condition is recognized as a risk factor for diabetes and cardiovascular disease. This study assessed the effects of the Sasang constitution group (SCG) on the risk of MS in Korean subjects. We have analyzed 1,617 outpatients of Korean oriental medicine hospitals who were classified into three SCGs, So-Yang, So-Eum, and Tae-Eum. Significant differences were noted in the prevalence of MS and the frequencies of all MS risk factors among the three SCGs. The odds ratios for MS as determined via multiple logistic regression analysis were 2.004 for So-Yang and 4.521 for Tae-Eum compared with So-Eum. These results indicate that SCG may function as a significant risk factor of MS; comprehensive knowledge of Sasang constitutional medicine may prove helpful in predicting susceptibility and developing preventive care techniques for MS.
Hybrid Cloud Computing Environment for EarthCube and Geoscience Community
NASA Astrophysics Data System (ADS)
Yang, C. P.; Qin, H.
2016-12-01
The NSF EarthCube Integration and Test Environment (ECITE) has built a hybrid cloud computing environment to provides cloud resources from private cloud environments by using cloud system software - OpenStack and Eucalyptus, and also manages public cloud - Amazon Web Service that allow resource synchronizing and bursting between private and public cloud. On ECITE hybrid cloud platform, EarthCube and geoscience community can deploy and manage the applications by using base virtual machine images or customized virtual machines, analyze big datasets by using virtual clusters, and real-time monitor the virtual resource usage on the cloud. Currently, a number of EarthCube projects have deployed or started migrating their projects to this platform, such as CHORDS, BCube, CINERGI, OntoSoft, and some other EarthCube building blocks. To accomplish the deployment or migration, administrator of ECITE hybrid cloud platform prepares the specific needs (e.g. images, port numbers, usable cloud capacity, etc.) of each project in advance base on the communications between ECITE and participant projects, and then the scientists or IT technicians in those projects launch one or multiple virtual machines, access the virtual machine(s) to set up computing environment if need be, and migrate their codes, documents or data without caring about the heterogeneity in structure and operations among different cloud platforms.
A Typology of UK Slot Machine Gamblers: A Longitudinal Observational and Interview Study
ERIC Educational Resources Information Center
Griffiths, Mark D.
2011-01-01
Slot machine gambling is a popular leisure activity worldwide yet there has been very little research into different types of slot machine gamblers. Earlier typologies of slot machine gamblers have only concentrated on adolescents in arcade environments. This study presents a new typology of slot machine players based on over 1000 h of participant…
77 FR 59243 - Aviation Rulemaking Advisory Committee Meeting on Transport Airplane and Engine Issues
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-26
... Committee Meeting on Transport Airplane and Engine Issues AGENCY: Federal Aviation Administration (FAA), DOT... Rulemaking Advisory Committee (ARAC) to discuss transport airplane and engine (TAE) issues. DATES: The... Prioritization Working Group Transport Canada Report Materials Flammability Working Group Report Avionics...
Human Machine Interfaces for Teleoperators and Virtual Environments
NASA Technical Reports Server (NTRS)
Durlach, Nathaniel I. (Compiler); Sheridan, Thomas B. (Compiler); Ellis, Stephen R. (Compiler)
1991-01-01
In Mar. 1990, a meeting organized around the general theme of teleoperation research into virtual environment display technology was conducted. This is a collection of conference-related fragments that will give a glimpse of the potential of the following fields and how they interplay: sensorimotor performance; human-machine interfaces; teleoperation; virtual environments; performance measurement and evaluation methods; and design principles and predictive models.
75 FR 55393 - Aviation Rulemaking Advisory Committee Meeting on Transport Airplane and Engine Issues
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-10
... Committee Meeting on Transport Airplane and Engine Issues AGENCY: Federal Aviation Administration (FAA), DOT... Rulemaking Advisory Committee (ARAC) to discuss transport airplane and engine (TAE) issues. DATES: The...: Opening Remarks, Review Agenda and Minutes. FAA Report. ARAC Executive Committee Report. Transport Canada...
78 FR 70216 - Airworthiness Directives; Thielert Aircraft Engines GmbH Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-25
... Airworthiness Directives; Thielert Aircraft Engines GmbH Reciprocating Engines AGENCY: Federal Aviation... all Thielert Aircraft Engines GmbH TAE 125-01 reciprocating engines. This AD requires applying sealant... directive (AD): 2013-24-06 Thielert Aircraft Engines GmbH: Amendment 39-17680; Docket No. FAA-2013-0561...
NASA Astrophysics Data System (ADS)
Rusica, I.; Toca, A.; Stingaci, I.; Scaticailov, S.; Scaticailov, I.; Marinescu, O.; Kosenko, P.
2016-11-01
In the paper we analyze the application lubricate cooling technological environment in the processing of various materials in the past century greatly have increased cutting speed and respectively, has increased productivity [1]. Today, none of production in which anyway is used metal cutting machines of all types (milling, turning, grinding, drilling, etc.) is not without lubricant cooling technological liquid which in turn are designed to reduce cutting force and the load on metal cutting machine tools and machined parts in order to increase durability machine tools and reduce errors of processing details and also in resource energy saving. When using lubricate cooling technological environment reduces the temperature in the cutting zone resulting in higher tool life and the preservation of the surface structure being treated reducing wear of metal parts of the machine. Typically, lubricant cooling process fluids is used without replacing as long as possible not yet beginning to negatively affect the quality of process. However life expectancy lubricate cooling technological environment is limited. According to existing normative acts every kind of lubricate cooling technological environment through certain time must be deleted by from the system and subjected to a recycling. Lubricate cooling technological environment must be disposed of for the following reasons: occurs the microbial and the mechanical pollution cutting fluid, free oil impairs operational characteristics cutting fluid and increases consumption.
Application of Fuzzy TOPSIS for evaluating machining techniques using sustainability metrics
NASA Astrophysics Data System (ADS)
Digalwar, Abhijeet K.
2018-04-01
Sustainable processes and techniques are getting increased attention over the last few decades due to rising concerns over the environment, improved focus on productivity and stringency in environmental as well as occupational health and safety norms. The present work analyzes the research on sustainable machining techniques and identifies techniques and parameters on which sustainability of a process is evaluated. Based on the analysis these parameters are then adopted as criteria’s to evaluate different sustainable machining techniques such as Cryogenic Machining, Dry Machining, Minimum Quantity Lubrication (MQL) and High Pressure Jet Assisted Machining (HPJAM) using a fuzzy TOPSIS framework. In order to facilitate easy arithmetic, the linguistic variables represented by fuzzy numbers are transformed into crisp numbers based on graded mean representation. Cryogenic machining was found to be the best alternative sustainable technique as per the fuzzy TOPSIS framework adopted. The paper provides a method to deal with multi criteria decision making problems in a complex and linguistic environment.
Lawrence, Sally; Boyle, Maria; Craypo, Lisa; Samuels, Sarah
2009-06-01
Little has been done to ensure that the foods sold within health care facilities promote healthy lifestyles. Policies to improve school nutrition environments can serve as models for health care organizations. This study was designed to assess the healthfulness of foods sold in health care facility vending machines as well as how health care organizations are using policies to create healthy food environments. Food and beverage assessments were conducted in 19 California health care facilities that serve children in the Healthy Eating, Active Communities sites. Items sold in vending machines were inventoried at each facility and interviews conducted for information on vending policies. Analyses examined the types of products sold and the healthfulness of these products. Ninety-six vending machines were observed in 15 (79%) of the facilities. Hospitals averaged 9.3 vending machines per facility compared with 3 vending machines per health department and 1.4 per clinic. Sodas comprised the greatest percentage of all beverages offered for sale: 30% in hospital vending machines and 38% in clinic vending machines. Water (20%) was the most prevalent in health departments. Candy comprised the greatest percentage of all foods offered in vending machines: 31% in clinics, 24% in hospitals, and 20% in health department facilities. Across all facilities, 75% of beverages and 81% of foods sold in vending machines did not adhere to the California school nutrition standards (Senate Bill 12). Nine (47%) of the health care facilities had adopted, or were in the process of adopting, policies that set nutrition standards for vending machines. According to the California school nutrition standards, the majority of items found in the vending machines in participating health care facilities were unhealthy. Consumption of sweetened beverages and high-energy-density foods has been linked to increased prevalence of obesity. Some health care facilities are developing policies that set nutrition standards for vending machines. These policies could be effective in increasing access to healthy foods and beverages in institutional settings.
A mechanical Turing machine: blueprint for a biomolecular computer
Shapiro, Ehud
2012-01-01
We describe a working mechanical device that embodies the theoretical computing machine of Alan Turing, and as such is a universal programmable computer. The device operates on three-dimensional building blocks by applying mechanical analogues of polymer elongation, cleavage and ligation, movement along a polymer, and control by molecular recognition unleashing allosteric conformational changes. Logically, the device is not more complicated than biomolecular machines of the living cell, and all its operations are part of the standard repertoire of these machines; hence, a biomolecular embodiment of the device is not infeasible. If implemented, such a biomolecular device may operate in vivo, interacting with its biochemical environment in a program-controlled manner. In particular, it may ‘compute’ synthetic biopolymers and release them into its environment in response to input from the environment, a capability that may have broad pharmaceutical and biological applications. PMID:22649583
Using PVM to host CLIPS in distributed environments
NASA Technical Reports Server (NTRS)
Myers, Leonard; Pohl, Kym
1994-01-01
It is relatively easy to enhance CLIPS (C Language Integrated Production System) to support multiple expert systems running in a distributed environment with heterogeneous machines. The task is minimized by using the PVM (Parallel Virtual Machine) code from Oak Ridge Labs to provide the distributed utility. PVM is a library of C and FORTRAN subprograms that supports distributive computing on many different UNIX platforms. A PVM deamon is easily installed on each CPU that enters the virtual machine environment. Any user with rsh or rexec access to a machine can use the one PVM deamon to obtain a generous set of distributed facilities. The ready availability of both CLIPS and PVM makes the combination of software particularly attractive for budget conscious experimentation of heterogeneous distributive computing with multiple CLIPS executables. This paper presents a design that is sufficient to provide essential message passing functions in CLIPS and enable the full range of PVM facilities.
NASA Astrophysics Data System (ADS)
Mia, Mozammel; Bashir, Mahmood Al; Dhar, Nikhil Ranjan
2016-07-01
Hard turning is gradually replacing the time consuming conventional turning process, which is typically followed by grinding, by producing surface quality compatible to grinding. The hard turned surface roughness depends on the cutting parameters, machining environments and tool insert configurations. In this article the variation of the surface roughness of the produced surfaces with the changes in tool insert configuration, use of coolant and different cutting parameters (cutting speed, feed rate) has been investigated. This investigation was performed in machining AISI 1060 steel, hardened to 56 HRC by heat treatment, using coated carbide inserts under two different machining environments. The depth of cut, fluid pressure and material hardness were kept constant. The Design of Experiment (DOE) was performed to determine the number and combination sets of different cutting parameters. A full factorial analysis has been performed to examine the effect of main factors as well as interaction effect of factors on surface roughness. A statistical analysis of variance (ANOVA) was employed to determine the combined effect of cutting parameters, environment and tool configuration. The result of this analysis reveals that environment has the most significant impact on surface roughness followed by feed rate and tool configuration respectively.
Practical Framework: Implementing OEE Method in Manufacturing Process Environment
NASA Astrophysics Data System (ADS)
Maideen, N. C.; Sahudin, S.; Mohd Yahya, N. H.; Norliawati, A. O.
2016-02-01
Manufacturing process environment requires reliable machineries in order to be able to satisfy the market demand. Ideally, a reliable machine is expected to be operated and produce a quality product at its maximum designed capability. However, due to some reason, the machine usually unable to achieved the desired performance. Since the performance will affect the productivity of the system, a measurement technique should be applied. Overall Equipment Effectiveness (OEE) is a good method to measure the performance of the machine. The reliable result produced from OEE can then be used to propose a suitable corrective action. There are a lot of published paper mentioned about the purpose and benefit of OEE that covers what and why factors. However, the how factor not yet been revealed especially the implementation of OEE in manufacturing process environment. Thus, this paper presents a practical framework to implement OEE and a case study has been discussed to explain in detail each steps proposed. The proposed framework is beneficial to the engineer especially the beginner to start measure their machine performance and later improve the performance of the machine.
Media-Augmented Exercise Machines
NASA Astrophysics Data System (ADS)
Krueger, T.
2002-01-01
Cardio-vascular exercise has been used to mitigate the muscle and cardiac atrophy associated with adaptation to micro-gravity environments. Several hours per day may be required. In confined spaces and long duration missions this kind of exercise is inevitably repetitive and rapidly becomes uninteresting. At the same time, there are pressures to accomplish as much as possible given the cost- per-hour for humans occupying orbiting or interplanetary. Media augmentation provides a the means to overlap activities in time by supplementing the exercise with social, recreational, training or collaborative activities and thereby reducing time pressures. In addition, the machine functions as an interface to a wide range of digital environments allowing for spatial variety in an otherwise confined environment. We hypothesize that the adoption of media augmented exercise machines will have a positive effect on psycho-social well-being on long duration missions. By organizing and supplementing exercise machines, data acquisition hardware, computers and displays into an interacting system this proposal increases functionality with limited additional mass. This paper reviews preliminary work on a project to augment exercise equipment in a manner that addresses these issues and at the same time opens possibilities for additional benefits. A testbed augmented exercise machine uses a specialty built cycle trainer as both input to a virtual environment and as an output device from it using spatialized sound, and visual displays, vibration transducers and variable resistance. The resulting interactivity increases a sense of engagement in the exercise, provides a rich experience of the digital environments. Activities in the virtual environment and accompanying physiological and psychological indicators may be correlated to track and evaluate the health of the crew.
Homeostatic and Circadian Abnormalities in Sleep and Arousal in Gulf War Syndrome
2016-10-01
prefrontal cortex have been reported in patients with clinical sleep disorders, including insomnia and cataplexy.7-9 A recent hdEEG analysis of...and parietal gray matter in chronic insomnia : a voxel-based morphometric study. Biol Psychiatry 2010;67:182-5. 8. Joo EY, Tae WS, Kim ST, Hong SB
Promoting Self-Regulation through School-Based Martial Arts Training
ERIC Educational Resources Information Center
Lakes, Kimberley D.; Hoyt, William T.
2004-01-01
The impact of school-based Tae Kwon Do training on self-regulatory abilities was examined. A self-regulation framework including three domains (cognitive, affective, and physical) was presented. Children (N = 207) from kindergarten through Grade 5 were randomly assigned by homeroom class to either the intervention (martial arts) group or a…
Active MHD Spectroscopy of Alfvén Eigenmodes on Alcator C-Mod
NASA Astrophysics Data System (ADS)
Sears, J.; Snipes, J.; Burke, W.; Parker, R.; Fasoli, A.
2004-11-01
Alfvén eigenmode resonances are excited in a variety of plasma conditions in C-Mod with two moderate-n antennas positioned above and below the outboard midplane. Power amplifiers (≈ 3 kW) sweep the driving frequency over the audio range (< 30 kHz) or over a selected ± 50 kHz range from 100 kHz to 1 MHz. Logic circuitry that calculates the center frequency of the Toroidal Alfven Eigenmode gap, f_TAE=v_A/4π qR, in real-time from BT and e measurements is being developed to enable the antennas to track f_TAE. Simultaneous in-vessel phase calibration of the pick-up coils will be used to better identify toroidal mode numbers. Shot-to-shot elongation scans do not show the dependence of damping on edge shear that was seen in results at JET. Inner wall limited plasmas with moderate outer gaps show higher damping rates than diverted plasmas with low outer gaps. Low frequency experiments below 20kHz will also be presented.
Guan, Haitao; Zou, Yinghua; Lv, Yongxing; Wang, Chao
2017-06-01
Perivascular epithelioid cell tumors (PEComas) are extremely rare mesenchymal entities with potentially malignant properties; the liver cases are not encountered frequently. Owing to themalignant potential, these tumors are treated by surgical methods to ensure total resection. In the present report, a case of liver PEComa treated by embolization combined with radiofrequency ablation (RFA) has been described. A 40-year-old female was admitted for the detection of a liver mass during an annual physical examination. The patient did not have any liver disease background, enhanced computed tomography (CT), and magnetic resonance revealed a huge mass in the right lobe. Pathology gave the diagnosis of PEComa, for disagreement of open surgery, a combination of transarterial embolization (TAE) and RFA were applied for treatment and the outcomes were acceptable, the patient was under follow-up to observe the long-term effect. Interventional procedures such as TAE and RFA are feasible and effective for such lesions and may serve as an alternate when resection is not indicated. Prospective studies are warranted to verify the long-term outcomes.
A comparison of different functions for predicted protein model quality assessment.
Li, Juan; Fang, Huisheng
2016-07-01
In protein structure prediction, a considerable number of models are usually produced by either the Template-Based Method (TBM) or the ab initio prediction. The purpose of this study is to find the critical parameter in assessing the quality of the predicted models. A non-redundant template library was developed and 138 target sequences were modeled. The target sequences were all distant from the proteins in the template library and were aligned with template library proteins on the basis of the transformation matrix. The quality of each model was first assessed with QMEAN and its six parameters, which are C_β interaction energy (C_beta), all-atom pairwise energy (PE), solvation energy (SE), torsion angle energy (TAE), secondary structure agreement (SSA), and solvent accessibility agreement (SAE). Finally, the alignment score (score) was also used to assess the quality of model. Hence, a total of eight parameters (i.e., QMEAN, C_beta, PE, SE, TAE, SSA, SAE, score) were independently used to assess the quality of each model. The results indicate that SSA is the best parameter to estimate the quality of the model.
NASA Astrophysics Data System (ADS)
Luo, K.; Sun, D. M.; Zhang, J.; Shen, Q.; Zhang, N.
2017-12-01
This study proposes a multi-stage travelling-wave thermoacoustically refrigeration system (TAD-RS) operating at liquefied natural gas temperature, which consists of two thermoacoustic engines (TAE) and one thermoacoustic refrigerator (TAR) in a closed-loop configuration. Three thermoacoustic units connect each other through a resonance tube of small cross-sectional area, achieving “self-matching” for efficient thermoacoustic conversion. Based on the linear thermoacoustic theory, a model of the proposed system has been built by using DeltaEC program to show the acoustic field characteristics and performance. It is shown that with pressurized 5 MPa helium as working gas, the TAEs are able to build a stable and strong acoustic field with a frequency of about 85 Hz. When hot end temperature reaches 923 K, this system can provide about 1410 W cooling power at 110 K with an overall exergy efficiency of 15.5%. This study indicates a great application prospect of TAD-RS in the field of natural gas liquefaction with a large cooling capacity and simple structure.
Ito, Arisa; Matsumoto, Hidetaka; Morimoto, Masahiro; Mimura, Kensuke; Akiyama, Hideo
2017-01-01
The aim of this study was to evaluate the efficacy of a treat-and-extend (TAE) regimen using intravitreal injection of aflibercept (IVA) for typical age-related macular degeneration (tAMD). We retrospectively studied 61 treatment-naïve eyes with tAMD. Best-corrected visual acuity (BCVA), central macular thickness (CMT), central choroidal thickness (CCT), number of injections, and complications during 2 years were evaluated. BCVA significantly improved by on average 0.13 logMAR units, and CMT and CCT significantly decreased after 2 years. The number of injections was on average 13.6. In the second year, eyes with classic choroidal neovascularization (CNV) needed significantly fewer treatments than eyes with occult CNV. Fourteen eyes, which developed subfoveal fibrosis, showed significantly poorer BCVA after 2 years. Subfoveal fibrosis was significantly common in classic CNV. A TAE regimen using IVA for tAMD might be effective for improving BCVA and exudative changes. The exudation may be suppressed with fewer treatments in classic CNV compared to occult CNV. © 2017 S. Karger AG, Basel.
Controlled English to facilitate human/machine analytical processing
NASA Astrophysics Data System (ADS)
Braines, Dave; Mott, David; Laws, Simon; de Mel, Geeth; Pham, Tien
2013-06-01
Controlled English is a human-readable information representation format that is implemented using a restricted subset of the English language, but which is unambiguous and directly accessible by simple machine processes. We have been researching the capabilities of CE in a number of contexts, and exploring the degree to which a flexible and more human-friendly information representation format could aid the intelligence analyst in a multi-agent collaborative operational environment; especially in cases where the agents are a mixture of other human users and machine processes aimed at assisting the human users. CE itself is built upon a formal logic basis, but allows users to easily specify models for a domain of interest in a human-friendly language. In our research we have been developing an experimental component known as the "CE Store" in which CE information can be quickly and flexibly processed and shared between human and machine agents. The CE Store environment contains a number of specialized machine agents for common processing tasks and also supports execution of logical inference rules that can be defined in the same CE language. This paper outlines the basic architecture of this approach, discusses some of the example machine agents that have been developed, and provides some typical examples of the CE language and the way in which it has been used to support complex analytical tasks on synthetic data sources. We highlight the fusion of human and machine processing supported through the use of the CE language and CE Store environment, and show this environment with examples of highly dynamic extensions to the model(s) and integration between different user-defined models in a collaborative setting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marelli, Laura; Stigliano, Rosa; Triantos, Christos
2007-02-15
Background. Chemoembolization (TACE) improves survival in cirrhotic patients with hepatocellular carcinoma (HCC). The optimal schedule, or whether embolization (TAE) alone gives the same survival advantage, is not known. Purpose. To evaluate whether specific patient characteristics and/or radiological transarterial techniques result in better outcomes. Method. A PubMed search was carried out for cohort and randomized trials (n = 175) testing transarterial therapies; meta-analysis was performed where appropriate. Results. Anticancer drugs were used as sole agent in 75% of cases (double 15% and triple 6%): doxorubicin (36%), cisplatin (31%), epirubicin (12%), mitoxantrone (8%), mitomycin (8%), and SMANCS (5%). Embolizing agents used were:more » gelatin sponge particles (71%), polyvinyl alcohol (PVA) particles (8%), degradable starch microspheres (DSM) (4%), and embospheres (4%). Sessions per patient were 2.5 {+-} 1.5 (interval: 2 months). Objective response was 40 {+-} 20%; survival rates at 1, 2, 3, and 5 years were: 62 {+-} 20%, 42 {+-} 17%, 30 {+-} 15%, and 19 {+-} 16%, respectively, and survival time was 18 {+-} 9.5 months. The post-TACE complications were: acute liver failure, 7.5% (range 0-49%); acute renal failure, 1.8% (0-13%); encephalopathy, 1.8% (0-16%); ascites, 8.3% (0-52%); upper gastrointestinal bleeding; 3% (0-22%); and hepatic or splenic abscess, 1.3% (0-2.5%). Treatment-related mortality was 2.4% (0-9.5%), mainly due to acute liver failure. Our meta-analysis of nine randomized controlled trials (RCTs) confirmed that TACE improves survival; but a meta-analysis of TACE versus TAE alone (3 RCTs, 412 patients) demonstrated no survival difference. Conclusions. No chemotherapeutic agent appears better than any other. There is no evidence for benefit with lipiodol. Gelatin sponge is the most used embolic agent, but PVA particles may be better. TAE appears as effective as TACE. New strategies to reduce the risk of post-TACE complications are required.« less
Toroidal Alfven Waves in Advanced Tokamaks
NASA Astrophysics Data System (ADS)
Berk, Herbert L.
2003-10-01
In burning plasma experiments, alpha particles have speeds that readily resonate with shear Alfven waves. It is essential to understand this Alfven wave spectrum for toroidal plasma confinement. Most interest has focused on the Toroidal Alfven Eigenmode (TAE), and a method of analysis has been developed to understand the structure of this mode at a flux surface with a given magnetic shear. However, this model fails when the shear is too low or reversed. In this case a new method of analysis is required, which must incorporate novel fluid-like effects from the energetic particles [1] and also include effects that are second order in the inverse toroidal aspect ratio. With this new method [2] we can obtain spectral features that agree with experimental results. In particular, this theory gives an explanation for the so-called Cascade modes that have been observed in JT-60 [3], JET [4], and TFTR [5]. For these Cascade modes, slow upward frequency sweeping is observed, beginning from frequencies below the TAE range but then often blending into the TAE range of frequencies. The theoretical understanding of the Cascades modes has evolved to the point where these modes can be used as a diagnostic "signature" [6] to experimentally optimize the formation of thermal barriers in reversed-shear operation when the minimum q value is an integer. [1] H. L. Berk et al., Phys. Rev. Lett. 87, 185 (2002). [2] B. N. Breizman et al., submitted to Phys. Plasmas (2003). [3] H. Kimura et al., Nucl. Fusion 38, 1303 (1998). [4] S. Sharapov et al., Phys. Lett. A 289, 127 (2001); S. Sharapov, Phys. Plasmas 9, 2027 (2002). [5] R. Nazikian, H. L. Berk, et al., Bull. Am. Phys. Soc. 47, 327 (2002). [6] E. Joffrin et al., Plasma Phys. Contr. Fusion 44, 1739 (2002); E. Joffrin et al., in Proc. 2002 IAEA Fusion Energy Conference, submitted to Nucl. Fusion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanimoto, Daigo, E-mail: daigoro@med.kawasaki-m.ac.jp; Ito, Katsuyoshi; Yamamoto, Akira
2010-10-15
This study was designed to evaluate the intravascular transformation behavior of superabsorbent polymer microsphere (SAP-MS) in vivo macroscopically by using monochromatic X-ray imaging and to quantitatively compare the expansion rate of SAP-MS among different kinds of mixtures. Fifteen rabbits were used for our study and transcatheter arterial embolization (TAE) was performed for their auricular arteries using monochromatic X-ray imaging. We used three kinds of SAP-MS (particle diameter 100-150 {mu}m) mixture as embolic spherical particles: SAP-MS(H) absorbed with sodium meglumine ioxaglate (Hexabrix 320), SAP-MS(V) absorbed with isosmolar contrast medium (Visipaque 270), and SAP-MS(S) absorbed with 0.9% sodium saline. The initial volumemore » of SAP-MS particles just after TAE and its final volume 10 minutes after TAE in the vessel were measured to calculate the expansion rate (ER) (n = 30). Intravascular behavior of SAP-MS particles was clearly observed in real time at monochromatic X-ray imaging. Averaged initial volumes of SAP-MS (H) (1.24 x 10{sup 7} {mu}m{sup 3}) were significantly smaller (p < 0.001) than those of SAP-MS (V) (5.99 x 10{sup 7} {mu}m{sup 3}) and SAP-MS (S) (5.85 x 10{sup 7} {mu}m{sup 3}). Averaged final volumes of SAP-MS (H) were significantly larger than averaged initial volumes (4.41 x 10{sup 7} {mu}m{sup 3} vs. 1.24 x 10{sup 7} {mu}m{sup 3}; p < 0.0001, ER = 3.55). There were no significant difference between averaged final volumes and averaged initial volumes of SAP-MS (V) and SAP-MS (S). SAP-MS (H), which first travels distally, reaches to small arteries, and then expands to adapt to the vessel lumen, is an effective particle as an embolic agent, causing effective embolization.« less
The Efficacy of Machine Learning Programs for Navy Manpower Analysis
1993-03-01
This thesis investigated the efficacy of two machine learning programs for Navy manpower analysis. Two machine learning programs, AIM and IXL, were...to generate models from the two commercial machine learning programs. Using a held out sub-set of the data the capabilities of the three models were...partial effects. The author recommended further investigation of AIM’s capabilities, and testing in an operational environment.... Machine learning , AIM, IXL.
Physics and Engineering Design of the ITER Electron Cyclotron Emission Diagnostic
NASA Astrophysics Data System (ADS)
Rowan, W. L.; Austin, M. E.; Houshmandyar, S.; Phillips, P. E.; Beno, J. H.; Ouroua, A.; Weeks, D. A.; Hubbard, A. E.; Stillerman, J. A.; Feder, R. E.; Khodak, A.; Taylor, G.; Pandya, H. K.; Danani, S.; Kumar, R.
2015-11-01
Electron temperature (Te) measurements and consequent electron thermal transport inferences will be critical to the non-active phases of ITER operation and will take on added importance during the alpha heating phase. Here, we describe our design for the diagnostic that will measure spatial and temporal profiles of Te using electron cyclotron emission (ECE). Other measurement capability includes high frequency instabilities (e.g. ELMs, NTMs, and TAEs). Since results from TFTR and JET suggest that Thomson Scattering and ECE differ at high Te due to driven non-Maxwellian distributions, non-thermal features of the ITER electron distribution must be documented. The ITER environment presents other challenges including space limitations, vacuum requirements, and very high-neutron-fluence. Plasma control in ITER will require real-time Te. The diagnosic design that evolved from these sometimes-conflicting needs and requirements will be described component by component with special emphasis on the integration to form a single effective diagnostic system. Supported by PPPL/US-DA via subcontract S013464-C to UT Austin.
CESAR research in intelligent machines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weisbin, C.R.
1986-01-01
The Center for Engineering Systems Advanced Research (CESAR) was established in 1983 as a national center for multidisciplinary, long-range research and development in machine intelligence and advanced control theory for energy-related applications. Intelligent machines of interest here are artificially created operational systems that are capable of autonomous decision making and action. The initial emphasis for research is remote operations, with specific application to dexterous manipulation in unstructured dangerous environments where explosives, toxic chemicals, or radioactivity may be present, or in other environments with significant risk such as coal mining or oceanographic missions. Potential benefits include reduced risk to man inmore » hazardous situations, machine replication of scarce expertise, minimization of human error due to fear or fatigue, and enhanced capability using high resolution sensors and powerful computers. A CESAR goal is to explore the interface between the advanced teleoperation capability of today, and the autonomous machines of the future.« less
[Cyclic fatigue of Vita mark II machinable ceramics under Hertzian's contact].
Liu, Wei-Cai; Zhang, Zhi-Shen; Huang, Cheng-Min; Chao, Yong-Lie; Wan, Qian-Bing
2006-08-01
To investigate the cyclic fatigue modes of Vita mark II machinable ceramics under Hertzian's contact. Hertzian's contact technique (WC spheres r = 3.18 mm) was used to investigate the cyclic fatigue of Vita mark II machinable ceramic. All specimens were fatigued by cyclic loading in moist environment, furthermore, surviving strength was examined by three point test and morphology damage observation. In homogeneous Vita mark II machinable ceramics, two fatigue damage modes existed after cyclic loading with spheres under moist environment, including conventional tensile-driven cone cracking (brittle mode) and shear-driven microdamage accumulation (quasi-plastic mode). The latter generated radial cracks and deeply penetrating secondary cone crack. Initial strength degradation were caused by the cone cracks, subsequent and much more deleterious loss was caused by radial cracks. Cyclic fatigue modes of Vita mark II machinable ceramics includes brittle and quasi-plastic mode.
1996-07-01
tetrazolium, inner salt; MTS; Promega], 1.9 mg/ml, and an electron coupling reagent ( phenazine methosulfate; PMS; Sigma), 0.044 mg/ml, in Dulbecco’s...acids PBS, phosphate buffered saline PCR, polymerase chain reaction PMS, phenazine methosulfate poly A, polyadenylation s.e., standard error TAE, tris
Nutrition environment measures survey-vending: development, dissemination, and reliability.
Voss, Carol; Klein, Susan; Glanz, Karen; Clawson, Margaret
2012-07-01
Researchers determined a need to develop an instrument to assess the vending machine environment that was comparably reliable and valid to other Nutrition Environment Measures Survey tools and that would provide consistent and comparable data for businesses, schools, and communities. Tool development, reliability testing, and dissemination of the Nutrition Environment Measures Survey-Vending (NEMS-V) involved a collaboration of students, professionals, and community leaders. Interrater reliability testing showed high levels of agreement among trained raters on the products and evaluations of products. NEMS-V can benefit public health partners implementing policy and environmental change initiatives as a part of their community wellness activities. The vending machine project will support a policy calling for state facilities to provide a minimum of 30% of foods and beverages in vending machines as healthy options, based on NEMS-V criteria, which will be used as a model for other businesses.
Burner Rig in the Material and Stresses Building
1969-11-21
A burner rig heats up a material sample in the Materials and Stresses Building at the National Aeronautics and Space Administration (NASA) Lewis Research Center. Materials technology is an important element in the successful development of advanced airbreathing and rocket propulsion systems. Different types of engines operate in different environments so an array of dependable materials is needed. NASA Lewis began investigating the characteristics of different materials shortly after World War II. In 1949 the materials group was expanded into its own division. The Lewis researchers sought to study and test materials in environments that simulate the environment in which they would operate. The Materials and Stresses Building, built in 1949, contained a number of laboratories to analyze the materials. They are subjected to high temperatures, high stresses, corrosion, irradiation, and hot gasses. The Physics of Solids Laboratory included a cyclotron, cloud chamber, helium cryostat, and metallurgy cave. The Metallographic Laboratory possessed six x-ray diffraction machines, two metalloscopes, and other equipment. The Furnace Room had two large induction machines, a 4500⁰ F graphite furnace, and heat treating equipment. The Powder Laboratory included 60-ton and 3000-ton presses. The Stresses Laboratory included stress rupture machines, fatigue machines, and tensile strength machines.
Proposed algorithm to improve job shop production scheduling using ant colony optimization method
NASA Astrophysics Data System (ADS)
Pakpahan, Eka KA; Kristina, Sonna; Setiawan, Ari
2017-12-01
This paper deals with the determination of job shop production schedule on an automatic environment. On this particular environment, machines and material handling system are integrated and controlled by a computer center where schedule were created and then used to dictate the movement of parts and the operations at each machine. This setting is usually designed to have an unmanned production process for a specified interval time. We consider here parts with various operations requirement. Each operation requires specific cutting tools. These parts are to be scheduled on machines each having identical capability, meaning that each machine is equipped with a similar set of cutting tools therefore is capable of processing any operation. The availability of a particular machine to process a particular operation is determined by the remaining life time of its cutting tools. We proposed an algorithm based on the ant colony optimization method and embedded them on matlab software to generate production schedule which minimize the total processing time of the parts (makespan). We test the algorithm on data provided by real industry and the process shows a very short computation time. This contributes a lot to the flexibility and timelines targeted on an automatic environment.
An assessment of the connection machine
NASA Technical Reports Server (NTRS)
Schreiber, Robert
1990-01-01
The CM-2 is an example of a connection machine. The strengths and problems of this implementation are considered as well as important issues in the architecture and programming environment of connection machines in general. These are contrasted to the same issues in Multiple Instruction/Multiple Data (MIMD) microprocessors and multicomputers.
Phenomenology tools on cloud infrastructures using OpenStack
NASA Astrophysics Data System (ADS)
Campos, I.; Fernández-del-Castillo, E.; Heinemeyer, S.; Lopez-Garcia, A.; Pahlen, F.; Borges, G.
2013-04-01
We present a new environment for computations in particle physics phenomenology employing recent developments in cloud computing. On this environment users can create and manage "virtual" machines on which the phenomenology codes/tools can be deployed easily in an automated way. We analyze the performance of this environment based on "virtual" machines versus the utilization of physical hardware. In this way we provide a qualitative result for the influence of the host operating system on the performance of a representative set of applications for phenomenology calculations.
ERIC Educational Resources Information Center
Hancock, Thomas E.; And Others
1995-01-01
In machine-mediated learning environments, there is a need for more reliable methods of calculating the probability that a learner's response will be correct in future trials. A combination of domain-independent response-state measures of cognition along with two instructional variables for maximum predictive ability are demonstrated. (Author/LRW)
Human-machine interface for a VR-based medical imaging environment
NASA Astrophysics Data System (ADS)
Krapichler, Christian; Haubner, Michael; Loesch, Andreas; Lang, Manfred K.; Englmeier, Karl-Hans
1997-05-01
Modern 3D scanning techniques like magnetic resonance imaging (MRI) or computed tomography (CT) produce high- quality images of the human anatomy. Virtual environments open new ways to display and to analyze those tomograms. Compared with today's inspection of 2D image sequences, physicians are empowered to recognize spatial coherencies and examine pathological regions more facile, diagnosis and therapy planning can be accelerated. For that purpose a powerful human-machine interface is required, which offers a variety of tools and features to enable both exploration and manipulation of the 3D data. Man-machine communication has to be intuitive and efficacious to avoid long accustoming times and to enhance familiarity with and acceptance of the interface. Hence, interaction capabilities in virtual worlds should be comparable to those in the real work to allow utilization of our natural experiences. In this paper the integration of hand gestures and visual focus, two important aspects in modern human-computer interaction, into a medical imaging environment is shown. With the presented human- machine interface, including virtual reality displaying and interaction techniques, radiologists can be supported in their work. Further, virtual environments can even alleviate communication between specialists from different fields or in educational and training applications.
NASA Astrophysics Data System (ADS)
Ghani, Jaharah A.; Mohd Rodzi, Mohd Nor Azmi; Zaki Nuawi, Mohd; Othman, Kamal; Rahman, Mohd. Nizam Ab.; Haron, Che Hassan Che; Deros, Baba Md
2011-01-01
Machining is one of the most important manufacturing processes in these modern industries especially for finishing an automotive component after the primary manufacturing processes such as casting and forging. In this study the turning parameters of dry cutting environment (without air, normal air and chilled air), various cutting speed, and feed rate are evaluated using a Taguchi optimization methodology. An orthogonal array L27 (313), signal-to-noise (S/N) ratio and analysis of variance (ANOVA) are employed to analyze the effect of these turning parameters on the performance of a coated carbide tool. The results show that the tool life is affected by the cutting speed, feed rate and cutting environment with contribution of 38%, 32% and 27% respectively. Whereas for the surface roughness, the feed rate is significantly controlled the machined surface produced by 77%, followed by the cutting environment of 19%. The cutting speed is found insignificant in controlling the machined surface produced. The study shows that the dry cutting environment factor should be considered in order to produce longer tool life as well as for obtaining a good machined surface.
Han-Markey, T L; Wang, L; Schlotterbeck, S; Jackson, E A; Gurm, R; Leidal, A; Eagle, K
2012-04-01
The school environment has been the focus of many health initiatives over the years as a means to address the childhood obesity crisis. The availability of low-nutrient, high-calorie foods and beverages to students via vending machines further exacerbates the issue of childhood obesity. However, a healthy overhaul of vending machines may also affect revenue on which schools have come to depend. This article describes the experience of one school district in changing the school environment, and the resulting impact on food and beverage vending machines. Observational study in Ann Arbor public schools. The contents and locations of vending machines were identified in 2003 and surveyed repeatedly in 2007. Overall revenues were also documented during this time period. Changes were observed in the contents of both food and beverage vending machines. Revenue in the form of commissions to the contracted companies and the school district decreased. Local and national wellness policy changes may have financial ramifications for school districts. In order to facilitate and sustain school environment change, all stakeholders, including teachers, administrators, students and healthcare providers, should collaborate and communicate on policy implementation, recognizing that change can have negative financial consequences as well as positive, healthier outcomes. Copyright © 2012 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Quantum cloning disturbed by thermal Davies environment
NASA Astrophysics Data System (ADS)
Dajka, Jerzy; Łuczka, Jerzy
2016-06-01
A network of quantum gates designed to implement universal quantum cloning machine is studied. We analyze how thermal environment coupled to auxiliary qubits, `blank paper' and `toner' required at the preparation stage of copying, modifies an output fidelity of the cloner. Thermal environment is described in terms of the Markovian Davies theory. We show that such a cloning machine is not universal any more but its output is independent of at least a part of parameters of the environment. As a case study, we consider cloning of states in a six-state cryptography's protocol. We also briefly discuss cloning of arbitrary input states.
Ergonomics for enhancing detection of machine abnormalities.
Illankoon, Prasanna; Abeysekera, John; Singh, Sarbjeet
2016-10-17
Detecting abnormal machine conditions is of great importance in an autonomous maintenance environment. Ergonomic aspects can be invaluable when detection of machine abnormalities using human senses is examined. This research outlines the ergonomic issues involved in detecting machine abnormalities and suggests how ergonomics would improve such detections. Cognitive Task Analysis was performed in a plant in Sri Lanka where Total Productive Maintenance is being implemented to identify sensory types that would be used to detect machine abnormalities and relevant Ergonomic characteristics. As the outcome of this research, a methodology comprising of an Ergonomic Gap Analysis Matrix for machine abnormality detection is presented.
Human Machine Learning Symbiosis
ERIC Educational Resources Information Center
Walsh, Kenneth R.; Hoque, Md Tamjidul; Williams, Kim H.
2017-01-01
Human Machine Learning Symbiosis is a cooperative system where both the human learner and the machine learner learn from each other to create an effective and efficient learning environment adapted to the needs of the human learner. Such a system can be used in online learning modules so that the modules adapt to each learner's learning state both…
ERIC Educational Resources Information Center
Sukwong, Orathai
2013-01-01
Virtualization enables the ability to consolidate multiple servers on a single physical machine, increasing the infrastructure utilization. Maximizing the ratio of server virtual machines (VMs) to physical machines, namely the consolidation ratio, becomes an important goal toward infrastructure cost saving in a cloud. However, the consolidation…
Draft Genome Sequence of Sphingopyxis sp. Strain MWB1, a Crude-Oil-Degrading Marine Bacterium
Kim, Jonghyun; Kim, Soo Jung; Kim, Seon Hee; Kim, Seung Il; Moon, Yoon-Jung; Park, Sung-Joon
2014-01-01
Sphingopyxis sp. strain MWB1, which is capable of degrading crude oil, diesel, and kerosene, was isolated from crude oil–contaminated seashore in Tae-an, South Korea. Here, we report the draft genome sequence of this strain, which comprises 3,118,428 bp with a G+C content of 62.85 mol%. PMID:25477411
NASA Technical Reports Server (NTRS)
1992-01-01
To convert raw data into environmental products, the National Weather Service and other organizations use the Global 9000 image processing system marketed by Global Imaging, Inc. The company's GAE software package is an enhanced version of the TAE, developed by Goddard Space Flight Center to support remote sensing and image processing applications. The system can be operated in three modes and is combined with HP Apollo workstation hardware.
1987-09-01
doctrine, especially joint doctrine. Because of this we make mistakes. I believe that the Air Force needs to develop a formal doctrinallo education...jresenteo arguments for all three points of view, but ne was particularly critical of tne educacional system within tae United States military. He said tnat
NASA Astrophysics Data System (ADS)
Wang, Ge; Berk, H. L.
2011-10-01
The frequency chirping signal arising from spontaneous a toroidial Alfven eigenmode (TAE) excited by energetic particles is studied for both numerical and analytic models. The time-dependent numerical model is based on the 1D Vlasov equation. We use a sophisticated tracking method to lock onto the resonant structure to enable the chirping frequency to be nearly constant in the calculation frame. The accuracy of the adiabatic approximation is tested during the simulation which justifies the appropriateness of our analytic model. The analytic model uses the adiabatic approximation which allows us to solve the wave evolution equation in frequency space. Then, the resonant interactions between energetic particles and TAE yield predictions for the chirping rate, wave frequency and amplitudes vs. time. Here, an adiabatic invariant J is defined on the separatrix of a chirping mode to determine the region of confinement of the wave trapped distribution function. We examine the asymptotic behavior of the chirping signal for its long time evolution and find agreement in essential features with the results of the simulation. Work supported by Department of Energy contract DE-FC02-08ER54988.
LBQ2D, Extending the Line Broadened Quasilinear Model to TAE-EP Interaction
NASA Astrophysics Data System (ADS)
Ghantous, Katy; Gorelenkov, Nikolai; Berk, Herbert
2012-10-01
The line broadened quasilinear model was proposed and tested on the one dimensional electrostatic case of the bump on tailfootnotetextH.L Berk, B. Breizman and J. Fitzpatrick, Nucl. Fusion, 35:1661, 1995 to study the wave particle interaction. In conventional quasilinear theory, the sea of overlapping modes evolve with time as the particle distribution function self consistently undergo diffusion in phase space. The line broadened quasilinear model is an extension to the conventional theory in a way that allows treatment of isolated modes as well as overlapping modes by broadening the resonant line in phase space. This makes it possible to treat the evolution of modes self consistently from onset to saturation in either case. We describe here the model denoted by LBQ2D which is an extension of the proposed one dimensional line broadened quasilinear model to the case of TAEs interacting with energetic particles in two dimensional phase space, energy as well as canonical angular momentum. We study the saturation of isolated modes in various regimes and present the analytical derivation and numerical results. Finally, we present, using ITER parameters, the case where multiple modes overlap and describe the techniques used for the numerical treatment.
Simulation of Chirping Avalanche in Neighborhood of TAE gap
NASA Astrophysics Data System (ADS)
Berk, Herb; Breizman, Boris; Wang, Ge; Zheng, Linjin
2016-10-01
A new kinetic code, CHIRP, focuses on the nonlinear response of resonant energetic particles (EPs) that destabilize Alfven waves which then can produce hole and clump phase space chirping structures, while the background plasma currents are assumed to respond linearly to the generated fields. EP currents are due to the motion arising from the perturbed field that is time averaged over an equilibrium orbit. A moderate EP source produces TAE chirping structures that have a limited range of chirping that do not reach the continuum. When the source is sufficiently strong, an EPM is excited in the lower continuum and it chirps rapidly downward as its amplitude rapidly grows in time. This response resembles the experimental observation of an avalanche, which occurs after a series of successive chirping events with a modest frequency shift, and then suddenly a rapid large amplitude and rapid frequency burst to low frequency with the loss of EPs. From these simulation observations we propose that in the experiment the EP population is slowly increasing to the point where the EPM is eventually excited. Supported by SCIDAC Center for Nonlinear Simulation of Energetic Particles Burning Plasmas (CSEP).
Kinetic electromagnetic instabilities in an ITB plasma with weak magnetic shear
NASA Astrophysics Data System (ADS)
Chen, W.; Yu, D. L.; Ma, R. R.; Shi, P. W.; Li, Y. Y.; Shi, Z. B.; Du, H. R.; Ji, X. Q.; Jiang, M.; Yu, L. M.; Yuan, B. S.; Li, Y. G.; Yang, Z. C.; Zhong, W. L.; Qiu, Z. Y.; Ding, X. T.; Dong, J. Q.; Wang, Z. X.; Wei, H. L.; Cao, J. Y.; Song, S. D.; Song, X. M.; Liu, Yi.; Yang, Q. W.; Xu, M.; Duan, X. R.
2018-05-01
Kinetic Alfvén and pressure gradient driven instabilities are very common in magnetized plasmas, both in space and the laboratory. These instabilities will be easily excited by energetic particles (EPs) and/or pressure gradients in present-day fusion and future burning plasmas. This will not only cause the loss and redistribution of the EPs, but also affect plasma confinement and transport. Alfvénic ion temperature gradient (AITG) instabilities with the frequency ω_BAE<ω<ω_TAE and the toroidal mode numbers n=2{-}8 are found to be unstable in NBI internal transport barrier plasmas with weak shear and low pressure gradients, where ω_BAE and ω_TAE are the frequencies of the beta- and toroidicity-induced Alfvén eigenmodes, respectively. The measured results are consistent with the general fishbone-like dispersion relation and kinetic ballooning mode equation, and the modes become more unstable the smaller the magnetic shear is in low pressure gradient regions. The interaction between AITG activity and EPs also needs to be investigated with greater attention in fusion plasmas, such as ITER (Tomabechi and The ITER Team 1991 Nucl. Fusion 31 1135), since these fluctuations can be enhanced by weak magnetic shear and EPs.
Problems in modeling man machine control behavior in biodynamic environments
NASA Technical Reports Server (NTRS)
Jex, H. R.
1972-01-01
Reviewed are some current problems in modeling man-machine control behavior in a biodynamic environment. It is given in two parts: (1) a review of the models which are appropriate for manual control behavior and the added elements necessary to deal with biodynamic interfaces; and (2) a review of some biodynamic interface pilot/vehicle problems which have occurred, been solved, or need to be solved.
1990-02-01
human-to- human communication patterns during situation assessment and cooperative problem solving tasks. The research proposed for the second URRP year...Hardware development. In order to create an environment within which to study multi-channeled human-to- human communication , a multi-media observation...that machine-to- human communication can be used to increase cohesion between humans and intelligent machines and to promote human-machine team
2011-01-01
Background Machine learning has a vast range of applications. In particular, advanced machine learning methods are routinely and increasingly used in quantitative structure activity relationship (QSAR) modeling. QSAR data sets often encompass tens of thousands of compounds and the size of proprietary, as well as public data sets, is rapidly growing. Hence, there is a demand for computationally efficient machine learning algorithms, easily available to researchers without extensive machine learning knowledge. In granting the scientific principles of transparency and reproducibility, Open Source solutions are increasingly acknowledged by regulatory authorities. Thus, an Open Source state-of-the-art high performance machine learning platform, interfacing multiple, customized machine learning algorithms for both graphical programming and scripting, to be used for large scale development of QSAR models of regulatory quality, is of great value to the QSAR community. Results This paper describes the implementation of the Open Source machine learning package AZOrange. AZOrange is specially developed to support batch generation of QSAR models in providing the full work flow of QSAR modeling, from descriptor calculation to automated model building, validation and selection. The automated work flow relies upon the customization of the machine learning algorithms and a generalized, automated model hyper-parameter selection process. Several high performance machine learning algorithms are interfaced for efficient data set specific selection of the statistical method, promoting model accuracy. Using the high performance machine learning algorithms of AZOrange does not require programming knowledge as flexible applications can be created, not only at a scripting level, but also in a graphical programming environment. Conclusions AZOrange is a step towards meeting the needs for an Open Source high performance machine learning platform, supporting the efficient development of highly accurate QSAR models fulfilling regulatory requirements. PMID:21798025
Stålring, Jonna C; Carlsson, Lars A; Almeida, Pedro; Boyer, Scott
2011-07-28
Machine learning has a vast range of applications. In particular, advanced machine learning methods are routinely and increasingly used in quantitative structure activity relationship (QSAR) modeling. QSAR data sets often encompass tens of thousands of compounds and the size of proprietary, as well as public data sets, is rapidly growing. Hence, there is a demand for computationally efficient machine learning algorithms, easily available to researchers without extensive machine learning knowledge. In granting the scientific principles of transparency and reproducibility, Open Source solutions are increasingly acknowledged by regulatory authorities. Thus, an Open Source state-of-the-art high performance machine learning platform, interfacing multiple, customized machine learning algorithms for both graphical programming and scripting, to be used for large scale development of QSAR models of regulatory quality, is of great value to the QSAR community. This paper describes the implementation of the Open Source machine learning package AZOrange. AZOrange is specially developed to support batch generation of QSAR models in providing the full work flow of QSAR modeling, from descriptor calculation to automated model building, validation and selection. The automated work flow relies upon the customization of the machine learning algorithms and a generalized, automated model hyper-parameter selection process. Several high performance machine learning algorithms are interfaced for efficient data set specific selection of the statistical method, promoting model accuracy. Using the high performance machine learning algorithms of AZOrange does not require programming knowledge as flexible applications can be created, not only at a scripting level, but also in a graphical programming environment. AZOrange is a step towards meeting the needs for an Open Source high performance machine learning platform, supporting the efficient development of highly accurate QSAR models fulfilling regulatory requirements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tal, J.; Lopez, A.; Edwards, J.M.
1995-04-01
In this paper, an alternative solution to the traditional CNC machine tool controller has been introduced. Software and hardware modules have been described and their incorporation in a CNC control system has been outlined. This type of CNC machine tool controller demonstrates that technology is accessible and can be readily implemented into an open architecture machine tool controller. Benefit to the user is greater controller flexibility, while being economically achievable. PC based, motion as well as non-motion features will provide flexibility through a Windows environment. Up-grading this type of controller system through software revisions will keep the machine tool inmore » a competitive state with minimal effort. Software and hardware modules are mass produced permitting competitive procurement and incorporation. Open architecture CNC systems provide diagnostics thus enhancing maintainability, and machine tool up-time. A major concern of traditional CNC systems has been operator training time. Training time can be greatly minimized by making use of Windows environment features.« less
NASA Technical Reports Server (NTRS)
Phillips, Jennifer K.
1995-01-01
Two of the current and most popular implementations of the Message-Passing Standard, Message Passing Interface (MPI), were contrasted: MPICH by Argonne National Laboratory, and LAM by the Ohio Supercomputer Center at Ohio State University. A parallel skyline matrix solver was adapted to be run in a heterogeneous environment using MPI. The Message-Passing Interface Forum was held in May 1994 which lead to a specification of library functions that implement the message-passing model of parallel communication. LAM, which creates it's own environment, is more robust in a highly heterogeneous network. MPICH uses the environment native to the machine architecture. While neither of these free-ware implementations provides the performance of native message-passing or vendor's implementations, MPICH begins to approach that performance on the SP-2. The machines used in this study were: IBM RS6000, 3 Sun4, SGI, and the IBM SP-2. Each machine is unique and a few machines required specific modifications during the installation. When installed correctly, both implementations worked well with only minor problems.
Building environment analysis based on temperature and humidity for smart energy systems.
Yun, Jaeseok; Won, Kwang-Ho
2012-10-01
In this paper, we propose a new HVAC (heating, ventilation, and air conditioning) control strategy as part of the smart energy system that can balance occupant comfort against building energy consumption using ubiquitous sensing and machine learning technology. We have developed ZigBee-based wireless sensor nodes and collected realistic temperature and humidity data during one month from a laboratory environment. With the collected data, we have established a building environment model using machine learning algorithms, which can be used to assess occupant comfort level. We expect the proposed HVAC control strategy will be able to provide occupants with a consistently comfortable working or home environment.
Garcia, Kristen M; Garney, Whitney R; Primm, Kristin M; McLeroy, Kenneth R
The American Heart Association conducted policy, systems, and environmental (PSE) focused interventions to increase healthy vending in 8 communities. PSE interventions were assessed using the Nutrition Environment Measures Survey Vending Assessment to see changes in the food environment. Baseline and follow-up assessments were conducted with 3 settings and a total of 19 machines. PSE changes resulted in increased availability of healthy options and decreased unhealthy options. Implementation of PSE interventions targeting the food environment can be an effective method of providing increased access to healthy foods and beverages with the goal of increasing consumption to decrease chronic diseases.
ERIC Educational Resources Information Center
Weatherly, Jeffrey N.; Thompson, Bradley J.; Hodny, Marisa; Meier, Ellen
2009-01-01
In a simulated casino environment, 6 nonpathological women played concurrently available commercial slot machines programmed to pay out at different rates. Participants did not always demonstrate preferences for the higher paying machine. The data suggest that factors other than programmed or obtained rate of reinforcement may control gambling…
An Operating Environment for the Jellybean Machine
1988-05-01
MODEL 48 5.4.4 Restarting a Context The operating system provides one primitive message (RESTART-CONTEXT) and two system calls (XFERID and XFER.ADDR) to...efficient, powerful services is reqired to support this "stem. To provide this supportive operating environment, I developed an operating system kernel that...serves many of the initial needs of our machine. This Jellybean Operating System Software provides an object- based storage model, where typed
ERIC Educational Resources Information Center
Pierpont, Katherine
2006-01-01
Greg Tang has a resume that could get his foot in the door to a lot of places. A graduate of Harvard with both a B.A. and M.A. in economics, Tang has found success as a business executive, a speechwriter, a software designer and owner of a Tae Kwon Do school. After the publication of his first best-selling book for children, "The Grapes of Math"…
1991-04-01
Navy Personnel Research and Development Center San Diego, California 92152-6800 TN-91-12 April 1991 AD-A236 411 Troubleshooting Assessment and...Program: Design, Development, and Administration Harry B. Conner Navy Personnel Research and Development Center Cathryn Poirier Randy Ulrich Thomas...Systems Department Approved for public release; distribution is unlimited. Navy Personnel Research and Development Center San Diego, California 92152-6800
An automated system for terrain database construction
NASA Technical Reports Server (NTRS)
Johnson, L. F.; Fretz, R. K.; Logan, T. L.; Bryant, N. A.
1987-01-01
An automated Terrain Database Preparation System (TDPS) for the construction and editing of terrain databases used in computerized wargaming simulation exercises has been developed. The TDPS system operates under the TAE executive, and it integrates VICAR/IBIS image processing and Geographic Information System software with CAD/CAM data capture and editing capabilities. The terrain database includes such features as roads, rivers, vegetation, and terrain roughness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McClements, K. G.; Fredrickson, E. D.
Spherical tokamaks (STs) typically have lower magnetic fields than conventional tokamaks, but similar mass densities. Suprathermal ions with relatively modest energies, in particular beam-injected ions, consequently have speeds close to or exceeding the Alfvén velocity, and can therefore excite a range of Alfvénic instabilities which could be driven by (and affect the behaviour of) fusion α-particles in a burning plasma. STs heated with neutral beams, including the small tight aspect ratio tokamak (START), the mega amp spherical tokamak (MAST), the national spherical torus experiment (NSTX) and Globus-M, have thus provided an opportunity to study toroidal Alfvén eigenmodes (TAEs), together withmore » higher frequency global Alfvén eigenmodes (GAEs) and compressional Alfvén eigenmodes (CAEs), which could affect beam current drive and channel fast ion energy into bulk ions in future devices. In NSTX GAEs were correlated with a degradation of core electron energy confinement. In MAST pulses with reduced magnetic field, CAEs were excited across a wide range of frequencies, extending to the ion cyclotron range, but were suppressed when hydrogen was introduced to the deuterium plasma, apparently due to mode conversion at ion–ion hybrid resonances. At lower frequencies fishbone instabilities caused fast particle redistribution in some MAST and NSTX pulses, but this could be avoided by moving the neutral beam line away from the magnetic axis or by operating the plasma at either high density or elevated safety factor. Fast ion redistribution has been observed during GAE avalanches on NSTX, while in both NSTX and MAST fast ions were transported by saturated kink modes, sawtooth crashes, resonant magnetic perturbations and TAEs. The energy dependence of fast ion redistribution due to both sawteeth and TAEs has been studied in Globus-M. High energy charged fusion products are unconfined in present-day STs, but have been shown in MAST to provide a useful diagnostic of beam ion behaviour, supplementing the information provided by neutron detectors. In MAST electrons were accelerated to highly suprathermal energies as a result of edge localised modes, while in both MAST and NSTX ions were accelerated due to internal reconnection events. Lastly, ion acceleration has also been observed during merging-compression start-up in MAST.« less
Energetic particles in spherical tokamak plasmas
NASA Astrophysics Data System (ADS)
McClements, K. G.; Fredrickson, E. D.
2017-05-01
Spherical tokamaks (STs) typically have lower magnetic fields than conventional tokamaks, but similar mass densities. Suprathermal ions with relatively modest energies, in particular beam-injected ions, consequently have speeds close to or exceeding the Alfvén velocity, and can therefore excite a range of Alfvénic instabilities which could be driven by (and affect the behaviour of) fusion α-particles in a burning plasma. STs heated with neutral beams, including the small tight aspect ratio tokamak (START), the mega amp spherical tokamak (MAST), the national spherical torus experiment (NSTX) and Globus-M, have thus provided an opportunity to study toroidal Alfvén eigenmodes (TAEs), together with higher frequency global Alfvén eigenmodes (GAEs) and compressional Alfvén eigenmodes (CAEs), which could affect beam current drive and channel fast ion energy into bulk ions in future devices. In NSTX GAEs were correlated with a degradation of core electron energy confinement. In MAST pulses with reduced magnetic field, CAEs were excited across a wide range of frequencies, extending to the ion cyclotron range, but were suppressed when hydrogen was introduced to the deuterium plasma, apparently due to mode conversion at ion-ion hybrid resonances. At lower frequencies fishbone instabilities caused fast particle redistribution in some MAST and NSTX pulses, but this could be avoided by moving the neutral beam line away from the magnetic axis or by operating the plasma at either high density or elevated safety factor. Fast ion redistribution has been observed during GAE avalanches on NSTX, while in both NSTX and MAST fast ions were transported by saturated kink modes, sawtooth crashes, resonant magnetic perturbations and TAEs. The energy dependence of fast ion redistribution due to both sawteeth and TAEs has been studied in Globus-M. High energy charged fusion products are unconfined in present-day STs, but have been shown in MAST to provide a useful diagnostic of beam ion behaviour, supplementing the information provided by neutron detectors. In MAST electrons were accelerated to highly suprathermal energies as a result of edge localised modes, while in both MAST and NSTX ions were accelerated due to internal reconnection events. Ion acceleration has also been observed during merging-compression start-up in MAST.
Ali, Habiba I; Jarrar, Amjad H; Abo-El-Enen, Mostafa; Al Shamsi, Mariam; Al Ashqar, Huda
2015-05-28
Increasing the healthfulness of campus food environments is an important step in promoting healthful food choices among college students. This study explored university students' suggestions on promoting healthful food choices from campus vending machines. It also examined factors influencing students' food choices from vending machines. Peer-led semi-structured individual interviews were conducted with 43 undergraduate students (33 females and 10 males) recruited from students enrolled in an introductory nutrition course in a large national university in the United Arab Emirates. Interviews were audiotaped, transcribed, and coded to generate themes using N-Vivo software. Accessibility, peer influence, and busy schedules were the main factors influencing students' food choices from campus vending machines. Participants expressed the need to improve the nutritional quality of the food items sold in the campus vending machines. Recommendations for students' nutrition educational activities included placing nutrition tips on or beside the vending machines and using active learning methods, such as competitions on nutrition knowledge. The results of this study have useful applications in improving the campus food environment and nutrition education opportunities at the university to assist students in making healthful food choices.
Automated visual imaging interface for the plant floor
NASA Astrophysics Data System (ADS)
Wutke, John R.
1991-03-01
The paper will provide an overview of the challenges facing a user of automated visual imaging (" AVI" ) machines and the philosophies that should be employed in designing them. As manufacturing tools and equipment become more sophisticated it is increasingly difficult to maintain an efficient interaction between the operator and machine. The typical user of an AVI machine in a production environment is technically unsophisticated. Also operator and machine ergonomics are often a neglected or poorly addressed part of an efficient manufacturing process. This paper presents a number of man-machine interface design techniques and philosophies that effectively solve these problems.
Intelligible machine learning with malibu.
Langlois, Robert E; Lu, Hui
2008-01-01
malibu is an open-source machine learning work-bench developed in C/C++ for high-performance real-world applications, namely bioinformatics and medical informatics. It leverages third-party machine learning implementations for more robust bug-free software. This workbench handles several well-studied supervised machine learning problems including classification, regression, importance-weighted classification and multiple-instance learning. The malibu interface was designed to create reproducible experiments ideally run in a remote and/or command line environment. The software can be found at: http://proteomics.bioengr. uic.edu/malibu/index.html.
My thoughts through a robot's eyes: an augmented reality-brain-machine interface.
Kansaku, Kenji; Hata, Naoki; Takano, Kouji
2010-02-01
A brain-machine interface (BMI) uses neurophysiological signals from the brain to control external devices, such as robot arms or computer cursors. Combining augmented reality with a BMI, we show that the user's brain signals successfully controlled an agent robot and operated devices in the robot's environment. The user's thoughts became reality through the robot's eyes, enabling the augmentation of real environments outside the anatomy of the human body.
NASA Technical Reports Server (NTRS)
Banda, Carolyn; Bushnell, David; Chen, Scott; Chiu, Alex; Constantine, Betsy; Murray, Jerry; Neukom, Christian; Prevost, Michael; Shankar, Renuka; Staveland, Lowell
1991-01-01
The Man-Machine Integration Design and Analysis System (MIDAS) is an integrated suite of software components that constitutes a prototype workstation to aid designers in applying human factors principles to the design of complex human-machine systems. MIDAS is intended to be used at the very early stages of conceptual design to provide an environment wherein designers can use computational representations of the crew station and operator, instead of hardware simulators and man-in-the-loop studies, to discover problems and ask 'what if' questions regarding the projected mission, equipment, and environment. This document is the Software Product Specification for MIDAS. Introductory descriptions of the processing requirements, hardware/software environment, structure, I/O, and control are given in the main body of the document for the overall MIDAS system, with detailed discussion of the individual modules included in Annexes A-J.
The HEPiX Virtualisation Working Group: Towards a Grid of Clouds
NASA Astrophysics Data System (ADS)
Cass, Tony
2012-12-01
The use of virtual machine images, as for example with Cloud services such as Amazon's Elastic Compute Cloud, is attractive for users as they have a guaranteed execution environment, something that cannot today be provided across sites participating in computing grids such as the Worldwide LHC Computing Grid. However, Grid sites often operate within computer security frameworks which preclude the use of remotely generated images. The HEPiX Virtualisation Working Group was setup with the objective to enable use of remotely generated virtual machine images at Grid sites and, to this end, has introduced the idea of trusted virtual machine images which are guaranteed to be secure and configurable by sites such that security policy commitments can be met. This paper describes the requirements and details of these trusted virtual machine images and presents a model for their use to facilitate the integration of Grid- and Cloud-based computing environments for High Energy Physics.
Building Environment Analysis based on Temperature and Humidity for Smart Energy Systems
Yun, Jaeseok; Won, Kwang-Ho
2012-01-01
In this paper, we propose a new HVAC (heating, ventilation, and air conditioning) control strategy as part of the smart energy system that can balance occupant comfort against building energy consumption using ubiquitous sensing and machine learning technology. We have developed ZigBee-based wireless sensor nodes and collected realistic temperature and humidity data during one month from a laboratory environment. With the collected data, we have established a building environment model using machine learning algorithms, which can be used to assess occupant comfort level. We expect the proposed HVAC control strategy will be able to provide occupants with a consistently comfortable working or home environment. PMID:23202004
NASA Astrophysics Data System (ADS)
Berzano, D.; Blomer, J.; Buncic, P.; Charalampidis, I.; Ganis, G.; Meusel, R.
2015-12-01
Cloud resources nowadays contribute an essential share of resources for computing in high-energy physics. Such resources can be either provided by private or public IaaS clouds (e.g. OpenStack, Amazon EC2, Google Compute Engine) or by volunteers computers (e.g. LHC@Home 2.0). In any case, experiments need to prepare a virtual machine image that provides the execution environment for the physics application at hand. The CernVM virtual machine since version 3 is a minimal and versatile virtual machine image capable of booting different operating systems. The virtual machine image is less than 20 megabyte in size. The actual operating system is delivered on demand by the CernVM File System. CernVM 3 has matured from a prototype to a production environment. It is used, for instance, to run LHC applications in the cloud, to tune event generators using a network of volunteer computers, and as a container for the historic Scientific Linux 5 and Scientific Linux 4 based software environments in the course of long-term data preservation efforts of the ALICE, CMS, and ALEPH experiments. We present experience and lessons learned from the use of CernVM at scale. We also provide an outlook on the upcoming developments. These developments include adding support for Scientific Linux 7, the use of container virtualization, such as provided by Docker, and the streamlining of virtual machine contextualization towards the cloud-init industry standard.
A Concept for Optimizing Behavioural Effectiveness & Efficiency
NASA Astrophysics Data System (ADS)
Barca, Jan Carlo; Rumantir, Grace; Li, Raymond
Both humans and machines exhibit strengths and weaknesses that can be enhanced by merging the two entities. This research aims to provide a broader understanding of how closer interactions between these two entities can facilitate more optimal goal-directed performance through the use of artificial extensions of the human body. Such extensions may assist us in adapting to and manipulating our environments in a more effective way than any system known today. To demonstrate this concept, we have developed a simulation where a semi interactive virtual spider can be navigated through an environment consisting of several obstacles and a virtual predator capable of killing the spider. The virtual spider can be navigated through the use of three different control systems that can be used to assist in optimising overall goal directed performance. The first two control systems use, an onscreen button interface and a touch sensor, respectively to facilitate human navigation of the spider. The third control system is an autonomous navigation system through the use of machine intelligence embedded in the spider. This system enables the spider to navigate and react to changes in its local environment. The results of this study indicate that machines should be allowed to override human control in order to maximise the benefits of collaboration between man and machine. This research further indicates that the development of strong machine intelligence, sensor systems that engage all human senses, extra sensory input systems, physical remote manipulators, multiple intelligent extensions of the human body, as well as a tighter symbiosis between man and machine, can support an upgrade of the human form.
Sallis, James F.; Swartz, Michael D.; Hoelscher, Deanna M.; Peskin, Melissa F.
2013-01-01
Introduction Hospitals are the primary worksite of over 5 million adults in the United States, and millions of meals are procured and consumed in this setting. Because many worksite nutrition initiatives use an ecological framework to improve the dietary habits of employees, the nutrition values of foods served in hospitals is receiving attention. Methods This study used the Hospital Nutrition Environment Scan for Cafeterias, Vending Machines, and Gift Shops to quantitatively describe the consumer nutrition environments of 39 hospitals in Southern California. Data were collected by visiting each facility once from February 2012 through May 2012. Results On average, hospitals achieved only 29%, 33%, and less than 1% of the total possible points for their cafeteria, vending machines, and gift shops sections, respectively; overall, hospitals scored 25% of the total possible points. Large facility size and contracted food service operations were associated with some healthy practices in hospital cafeterias, but we found no association between these variables and the sectional or overall nutrition composite scores. Conclusion The average consumer nutrition environment of hospitals in this sample was minimally conducive to healthful eating. Nutrition-related interventions are warranted in hospital settings. PMID:23823699
Winston, Courtney P; Sallis, James F; Swartz, Michael D; Hoelscher, Deanna M; Peskin, Melissa F
2013-07-03
Hospitals are the primary worksite of over 5 million adults in the United States, and millions of meals are procured and consumed in this setting. Because many worksite nutrition initiatives use an ecological framework to improve the dietary habits of employees, the nutrition values of foods served in hospitals is receiving attention. This study used the Hospital Nutrition Environment Scan for Cafeterias, Vending Machines, and Gift Shops to quantitatively describe the consumer nutrition environments of 39 hospitals in Southern California. Data were collected by visiting each facility once from February 2012 through May 2012. On average, hospitals achieved only 29%, 33%, and less than 1% of the total possible points for their cafeteria, vending machines, and gift shops sections, respectively; overall, hospitals scored 25% of the total possible points. Large facility size and contracted food service operations were associated with some healthy practices in hospital cafeterias, but we found no association between these variables and the sectional or overall nutrition composite scores. The average consumer nutrition environment of hospitals in this sample was minimally conducive to healthful eating. Nutrition-related interventions are warranted in hospital settings.
Virtual C Machine and Integrated Development Environment for ATMS Controllers.
DOT National Transportation Integrated Search
2000-04-01
The overall objective of this project is to develop a prototype virtual machine that fits on current Advanced Traffic Management Systems (ATMS) controllers and provides functionality for complex traffic operations.;Prepared in cooperation with Utah S...
Stochastic subset selection for learning with kernel machines.
Rhinelander, Jason; Liu, Xiaoping P
2012-06-01
Kernel machines have gained much popularity in applications of machine learning. Support vector machines (SVMs) are a subset of kernel machines and generalize well for classification, regression, and anomaly detection tasks. The training procedure for traditional SVMs involves solving a quadratic programming (QP) problem. The QP problem scales super linearly in computational effort with the number of training samples and is often used for the offline batch processing of data. Kernel machines operate by retaining a subset of observed data during training. The data vectors contained within this subset are referred to as support vectors (SVs). The work presented in this paper introduces a subset selection method for the use of kernel machines in online, changing environments. Our algorithm works by using a stochastic indexing technique when selecting a subset of SVs when computing the kernel expansion. The work described here is novel because it separates the selection of kernel basis functions from the training algorithm used. The subset selection algorithm presented here can be used in conjunction with any online training technique. It is important for online kernel machines to be computationally efficient due to the real-time requirements of online environments. Our algorithm is an important contribution because it scales linearly with the number of training samples and is compatible with current training techniques. Our algorithm outperforms standard techniques in terms of computational efficiency and provides increased recognition accuracy in our experiments. We provide results from experiments using both simulated and real-world data sets to verify our algorithm.
DICE: An Object Oriented Programming Environment for Cooperative Engineering Design
1989-03-20
environment called PARMENIDES /FRULEKIT; PARMENIDES /FRULEKIT supports programming in frames and rules and was developed in LISP at Carnegie-Mellon...the domain of building design and construction. The Blackboard in DICEY-BUILDER is represented as frames in PARMENIDES , while the KMs are implemented... PARMENIDES fo rart omat format d a b C /envelope BLACKBOAR D machine to machine (’BLACKBOARD l m message f il transfer message p read •d message format J
NASA Technical Reports Server (NTRS)
Burke, Gary R.; Taft, Stephanie
2004-01-01
State machines are commonly used to control sequential logic in FPGAs and ASKS. An errant state machine can cause considerable damage to the device it is controlling. For example in space applications, the FPGA might be controlling Pyros, which when fired at the wrong time will cause a mission failure. Even a well designed state machine can be subject to random errors us a result of SEUs from the radiation environment in space. There are various ways to encode the states of a state machine, and the type of encoding makes a large difference in the susceptibility of the state machine to radiation. In this paper we compare 4 methods of state machine encoding and find which method gives the best fault tolerance, as well as determining the resources needed for each method.
Theoretical and Experimental Study of Thermoacoustic Engines
1991-12-31
possible. In particulbr, we have considered use of extruded ceramic monolithic catalyst supports (for example, the ceramic used in some automobile...approximation. Heat exchangers retaken r be of negligible thickness and thus not to affect near-standing wave phasing. The TAB (or snack ) of length d is assumed...Heat exchangers were parallel plates of copper and the TAE is a monolithic catalyst support extruded ceramic. 13 15 The two-microphone-technique
U. S. Naval Forces, Vietnam Monthly Historical Supplement for August 1967
1967-11-25
within the perimeter of the base. No personnel injuries occurred during the second attack. On 1 August the NAVSUPPACT detachment previously...Instruction in tae-lcwon-do, the Korean foim of karate . Each month a Vietnamese Navy LSSL (Landing Ship, Support, Large) embarks a group of...held in the language laboratory, and two Korean Amy officers conduct the karate instruc- tion. Assistance in all areas of administration and
Energy Efficient Signal Detection for Army Applications Based on Ordering
2011-09-01
Systems, (07 2010): 0. doi: 10.1109/TAES.2010.5545189 2011/09/03 18:03:52 35 Qian He, Rick S. Blum, Alexander M. Haimovich. Noncoherent MIMO Radar for...Conference Proceeding publications (other than abstracts): PaperReceived . Noncoherent Versus Coherent MIMO Radar for Joint TargetPosition and Velocity... noncoherent signal detection for networked sensors using ordered transmissions, 2011 45th Annual Conference on Information Sciences and Systems (CISS
Deuterium-tritium experiments on the Tokamak Fusion Test reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hosea, J.; Adler, J.H.; Alling, P.
The deuterium-tritium (D-T) experimental program on the Tokamak Fusion Test Reactor (TFTR) is underway and routine tritium operations have been established. The technology upgrades made to the TFTR facility have been demonstrated to be sufficient for supporting both operations and maintenance for an extended D-T campaign. To date fusion power has been increased to {approx}9 MW and several physics results of importance to the D-T reactor regime have been obtained: electron temperature, ion temperature, and plasma stored energy all increase substantially in the D-T regime relative to the D-D regime at the same neutral beam power and comparable limiter conditioning;more » possible alpha electron heating is indicated and energy confinement improvement with average ion mass is observed; and alpha particle losses appear to be classical with no evidence of TAE mode activity up to the PFUS {approx}6 MW level. Instability in the TAE mode frequency range has been observed at PFUS > 7 MW and its effect on performance in under investigation. Preparations are underway to enhance the alpha particle density further by increasing fusion power and by extending the neutral beam pulse length to permit alpha particle effects of relevance to the ITER regime to be more fully explored.« less
Transarterial embolization of metastatic mediastinal hepatocellular carcinoma
Chen, Chia-Chang; Yeh, Hong-Zen; Chang, Chi-Sen; Ko, Chung-Wang; Lien, Han-Chung; Wu, Chun-Ying; Hung, Siu-Wan
2013-01-01
This paper introduces an innovative treatment for extra-hepatic metastasis of hepatocellular carcinoma. A 71-year-old patient had a stable liver condition following treatment for hepatocellular carcinoma, but later developed symptomatic mediastinal metastasis. This rapidly growing mediastinal mass induced symptoms including cough and hoarseness. Serial sessions of transarterial embolization (TAE) successfully controlled this mediastinal mass with limited side effects. The patient’s survival time since the initial diagnosis of the mediastinal hepatocellular carcinoma was 32 mo, significantly longer than the 12 mo mean survival period of patients with similar diagnoses: metastatic hepatocellular carcinoma and a liver condition with a Child-Pugh class A score. Currently, oral sorafenib is the treatment of choice for metastatic hepatocellular carcinoma. Recent studies indicate that locoregional treatment of extra-hepatic metastasis of hepatocellular carcinomas might also significantly improve the prognosis in patients with their primary hepatic lesions under control. Many effective locoregional therapies for extrahepatic metastasis, including radiation and surgical resection, may provide palliative effects for hepatocellular carcinoma-associated mediastinal metastasis. This case report demonstrates that TAE of metastatic mediastinal hepatocellular carcinoma provided this patient with tumor control and increased survival time. This finding is important as it can potentially provide an alternative treatment option for patients with similar symptoms and diagnoses. PMID:23801848
Mangiavillano, Benedetto; Khashab, Mouen A; Eusebi, Leonardo H; Tarantino, Ilaria; Bianchetti, Mario; Semeraro, Rossella; Pellicano, Rinaldo; Traina, Mario; Repici, Alessandro
2018-05-31
The two most relevant endoscopic treatable benign biliary diseases (BBD) are benign biliary strictures (BBSs) and biliary leaks (BLs), often associated with high morbidity. The most common endoscopic treatment for biliary strictures involves placement of multiple plastic stents (PSs), with or without balloon dilation, followed by planned exchange of the stents. Thus, there continues to be high interest in pursuing alternative endoscopic approaches that may achieve better results with fewer interventions. In this setting, the use of a fully-covered, self-expandable metal stent (FCSEMS) is an attractive alternative to single or multiple PSs for the treatment of BBDs. A single metal stent can remain in place for a longer period of time before removal; however, the maximum time the stent can be remain in place is still not well defined. The aim of this review is to determine the removal time of the TaeWoong® FCSEMS, placed for BBD. According to our data analysis, considering the absence of loss of the covering of the FCSEMS and of any adverse events during and after stent removal, leaving the TaeWoong medical FCSEMS in situ for an 8 months' period seems to be acceptable for benign biliary diseases. Further studies need to evaluate their removability at 1 year.
Tae-Eum Type as an Independent Risk Factor for Obstructive Sleep Apnea
Lee, Seung Ku; Yoon, Dae Wui; Yi, Hyeryeon; Lee, Si Woo; Kim, Jong Yeol; Shin, Chol
2013-01-01
Obstructive sleep apnea (OSA) is prevalent and associated with several kinds of chronic diseases. There has been evidence that a specific type of Sasang constitution is a risk factor for metabolic and cardiovascular diseases that can be found in patients with OSA, but there are no studies that address the association between the Sasang constitution type (SCT) and OSA. The purpose of this study was to investigate the association between the SCT and OSA. A total of 652 participants were included. All participants were examined for demographic information, medical history, and completed an interviewer-administered questionnaire on life style and sleep-related variables. Biochemical analyses were performed to determine the glucose and lipid profiles. An objective recording of OSA was done with an unattended home PSG using an Embla portable device. The apnea-hypopnea index (AHI) and oxygen desaturation index (ODI) were significantly higher in the Tae-eum (TE) type as compared to the So-eum (SE) and the So-yang (SY) types. Even after adjusting for confounding variables, the TE type still had a 2.34-fold (95% CI, 1.11–4.94; P = 0.0262) increased risk for OSA. This population-based cohort study found that the TE constitutional type is an independent risk factor for the development of OSA. PMID:23554836
Effect of implementation of safety measures in tae kwon do competition
Burke, D; Barfoot, K; Bryant, S; Schneider, J; Kim, H; Levin, G
2003-01-01
Background: Previous reviews of tae kwon do (TKD) tournaments have documented injury rates of 25/1000 to 12.7/100 athlete exposures. Most injuries have been reported to be to the head and the neck and are occasionally very serious. Many of these studies involved high level TKD competitions with minimal safety precautions. Recently, safety measures have been implemented in many TKD competitions. Objective: To evaluate retrospectively the incidence of injuries in TKD competitions involving a wide range of participants and featuring extensive safety precautions. Methods: A total of 2498 participants ranged in age from 18 to 66, included both men and women, and ranged in rank from yellow to black belt. Traumas, defined as any event requiring interaction with medical staff, were documented with respect to mechanism, diagnosis, treatment, and follow up recommendations. An injury was defined as a trauma that prevented a contestant from resuming competition on the day that the trauma occurred, according to National Collegiate Athletic Association criteria. Results: The injury rate was 0.4/1000 athlete exposures. This is lower than reported in previous studies of TKD tournaments and in many other sports. Conclusion: TKD tournaments that emphasise limited contact, protective equipment, and medical supervision are relatively safe and compare favourably with other sports. PMID:14514529
Ono, Fuminori; Hiraga, Masaki; Omura, Noriyuki; Sato, Manabu; Yamamura, Akihiro; Obara, Megumi; Sato, Jun; Onochi, Shoichi
2012-10-10
We report a rare case in which hemothorax occurred in addition to hemoperitoneum due to spontaneous rupture of hepatocellular carcinoma (HCC) originating from the caudate lobe of the liver. The case pertains to a 56-year-old female who was transported to our hospital for impaired consciousness due to hemorrhagic shock. Computed tomography (CT) demonstrated ruptured HCC originating from the caudate lobe and accompanying hemoperitoneum and right hemothorax. Hemostasis was carried out by transcatheter arterial embolization (TAE), and surgery was conducted approximately one month after TAE. In the present case, no lesions as possible sources of bleeding were observed inside the pleural cavity, and, moreover, the diaphragm had no abnormalities in the intraoperative findings, suggesting that blood from the ruptured tumor may have traversed the intact diaphragm to enter the right pleural cavity soon after the HCC rupture. However, to the best of our knowledge, no similar cases of HCC have been reported to date, and this case is thus believed to be very rare. This unusual phenomenon may therefore be strongly associated with the location of the ruptured tumor and the formation of a hematoma inside the omental bursa. We discuss the mechanism causing hemothorax in the present case and also review the previously reported cases of ruptured HCC complicated by hemothorax.
2012-01-01
We report a rare case in which hemothorax occurred in addition to hemoperitoneum due to spontaneous rupture of hepatocellular carcinoma (HCC) originating from the caudate lobe of the liver. The case pertains to a 56-year-old female who was transported to our hospital for impaired consciousness due to hemorrhagic shock. Computed tomography (CT) demonstrated ruptured HCC originating from the caudate lobe and accompanying hemoperitoneum and right hemothorax. Hemostasis was carried out by transcatheter arterial embolization (TAE), and surgery was conducted approximately one month after TAE. In the present case, no lesions as possible sources of bleeding were observed inside the pleural cavity, and, moreover, the diaphragm had no abnormalities in the intraoperative findings, suggesting that blood from the ruptured tumor may have traversed the intact diaphragm to enter the right pleural cavity soon after the HCC rupture. However, to the best of our knowledge, no similar cases of HCC have been reported to date, and this case is thus believed to be very rare. This unusual phenomenon may therefore be strongly associated with the location of the ruptured tumor and the formation of a hematoma inside the omental bursa. We discuss the mechanism causing hemothorax in the present case and also review the previously reported cases of ruptured HCC complicated by hemothorax. PMID:23046863
Yang, Lin; Li, Guangchao; Zhao, Likun; Pan, Fei; Qiang, Jiankun; Han, Siqi
2014-10-01
Targeted therapy based on ALK tyrosine kinase inhibitors (ALK-TKIs) has made significant achievements in individuals with EML4-ALK (echinoderm microtubule-associated protein-like 4 gene and the anaplastic lymphoma kinase gene) fusion positive nonsmall-cell lung cancer (NSCLC). However, a high fraction of patients receive inferior clinical response to such treatment in the initial therapy, and the exact mechanisms underlying this process need to be further investigated. In this study, we revealed a persistently activated PI3K/AKT signaling that mediates the drug ineffectiveness. We found that genetic or pharmacological inhibition of ALK markedly abrogated phosphorylated STAT3 and ERK, but it failed to suppress AKT activity or induce apoptosis, in EML4-ALK-positive H2228 cells. Furthermore, targeted RNA interference of PI3K pathway components restored sensitivity to TAE684 treatment at least partially due to increased apoptosis. Combined TAE684 with PI3K inhibitor synergistically inhibited the proliferation of EML4-ALK-positive cells in vitro and significantly suppressed the growth of H2228 xenografts in vivo, suggesting the potential clinical application of such combinatorial therapy regimens in patients with EML4-ALK positive lung cancer.
A hardware/software environment to support R D in intelligent machines and mobile robotic systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mann, R.C.
1990-01-01
The Center for Engineering Systems Advanced Research (CESAR) serves as a focal point at the Oak Ridge National Laboratory (ORNL) for basic and applied research in intelligent machines. R D at CESAR addresses issues related to autonomous systems, unstructured (i.e. incompletely known) operational environments, and multiple performing agents. Two mobile robot prototypes (HERMIES-IIB and HERMIES-III) are being used to test new developments in several robot component technologies. This paper briefly introduces the computing environment at CESAR which includes three hypercube concurrent computers (two on-board the mobile robots), a graphics workstation, VAX, and multiple VME-based systems (several on-board the mobile robots).more » The current software environment at CESAR is intended to satisfy several goals, e.g.: code portability, re-usability in different experimental scenarios, modularity, concurrent computer hardware transparent to applications programmer, future support for multiple mobile robots, support human-machine interface modules, and support for integration of software from other, geographically disparate laboratories with different hardware set-ups. 6 refs., 1 fig.« less
An intelligent CNC machine control system architecture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D.J.; Loucks, C.S.
1996-10-01
Intelligent, agile manufacturing relies on automated programming of digitally controlled processes. Currently, processes such as Computer Numerically Controlled (CNC) machining are difficult to automate because of highly restrictive controllers and poor software environments. It is also difficult to utilize sensors and process models for adaptive control, or to integrate machining processes with other tasks within a factory floor setting. As part of a Laboratory Directed Research and Development (LDRD) program, a CNC machine control system architecture based on object-oriented design and graphical programming has been developed to address some of these problems and to demonstrate automated agile machining applications usingmore » platform-independent software.« less
Scheduling of flow shop problems on 3 machines in fuzzy environment with double transport facility
NASA Astrophysics Data System (ADS)
Sathish, Shakeela; Ganesan, K.
2016-06-01
Flow shop scheduling is a decision making problem in production and manufacturing field which has a significant impact on the performance of an organization. When the machines on which jobs are to be processed are placed at different places, the transportation time plays a significant role in production. Further two different transport agents where 1st takes the job from 1st machine to 2nd machine and then returns back to the first machine and the 2nd takes the job from 2nd machine to 3rd machine and then returns back to the 2nd machine are also considered. We propose a method to minimize the total make span; without converting the fuzzy processing time to classical numbers by using a new type of fuzzy arithmetic and a fuzzy ranking method. A numerical example is provided to explain the proposed method.
A machine learning approach to galaxy-LSS classification - I. Imprints on halo merger trees
NASA Astrophysics Data System (ADS)
Hui, Jianan; Aragon, Miguel; Cui, Xinping; Flegal, James M.
2018-04-01
The cosmic web plays a major role in the formation and evolution of galaxies and defines, to a large extent, their properties. However, the relation between galaxies and environment is still not well understood. Here, we present a machine learning approach to study imprints of environmental effects on the mass assembly of haloes. We present a galaxy-LSS machine learning classifier based on galaxy properties sensitive to the environment. We then use the classifier to assess the relevance of each property. Correlations between galaxy properties and their cosmic environment can be used to predict galaxy membership to void/wall or filament/cluster with an accuracy of 93 per cent. Our study unveils environmental information encoded in properties of haloes not normally considered directly dependent on the cosmic environment such as merger history and complexity. Understanding the physical mechanism by which the cosmic web is imprinted in a halo can lead to significant improvements in galaxy formation models. This is accomplished by extracting features from galaxy properties and merger trees, computing feature scores for each feature and then applying support vector machine (SVM) to different feature sets. To this end, we have discovered that the shape and depth of the merger tree, formation time, and density of the galaxy are strongly associated with the cosmic environment. We describe a significant improvement in the original classification algorithm by performing LU decomposition of the distance matrix computed by the feature vectors and then using the output of the decomposition as input vectors for SVM.
NASA Astrophysics Data System (ADS)
Adeyeri, Michael Kanisuru; Mpofu, Khumbulani
2017-06-01
The article is centred on software system development for manufacturing company that produces polyethylene bags using mostly conventional machines in a competitive world where each business enterprise desires to stand tall. This is meant to assist in gaining market shares, taking maintenance and production decisions by the dynamism and flexibilities embedded in the package as customers' demand varies under the duress of meeting the set goals. The production and machine condition monitoring software (PMCMS) is programmed in C# and designed in such a way to support hardware integration, real-time machine conditions monitoring, which is based on condition maintenance approach, maintenance decision suggestions and suitable production strategies as the demand for products keeps changing in a highly competitive environment. PMCMS works with an embedded device which feeds it with data from the various machines being monitored at the workstation, and the data are read at the base station through transmission via a wireless transceiver and stored in a database. A case study was used in the implementation of the developed system, and the results show that it can monitor the machine's health condition effectively by displaying machines' health status, gives repair suggestions to probable faults, decides strategy for both production methods and maintenance, and, thus, can enhance maintenance performance obviously.
A Machine-Learning-Driven Sky Model.
Satylmys, Pynar; Bashford-Rogers, Thomas; Chalmers, Alan; Debattista, Kurt
2017-01-01
Sky illumination is responsible for much of the lighting in a virtual environment. A machine-learning-based approach can compactly represent sky illumination from both existing analytic sky models and from captured environment maps. The proposed approach can approximate the captured lighting at a significantly reduced memory cost and enable smooth transitions of sky lighting to be created from a small set of environment maps captured at discrete times of day. The author's results demonstrate accuracy close to the ground truth for both analytical and capture-based methods. The approach has a low runtime overhead, so it can be used as a generic approach for both offline and real-time applications.
Computers Simulate Human Experts.
ERIC Educational Resources Information Center
Roberts, Steven K.
1983-01-01
Discusses recent progress in artificial intelligence in such narrowly defined areas as medical and electronic diagnosis. Also discusses use of expert systems, man-machine communication problems, novel programing environments (including comments on LISP and LISP machines), and types of knowledge used (factual, heuristic, and meta-knowledge). (JN)
Minaker, Leia M; Storey, Kate E; Raine, Kim D; Spence, John C; Forbes, Laura E; Plotnikoff, Ronald C; McCargar, Linda J
2011-08-01
The increasing prevalence of obesity among youth has elicited calls for schools to become more active in promoting healthy weight. The present study examined associations between various aspects of school food environments (specifically the availability of snack- and beverage-vending machines and the presence of snack and beverage logos) and students' weight status, as well as potential influences of indices of diet and food behaviours. A cross-sectional, self-administered web-based survey. A series of multinomial logistic regressions with generalized estimating equations (GEE) were constructed to examine associations between school environment variables (i.e. the reported presence of beverage- and snack-vending machines and logos) and self-reported weight- and diet-related behaviours. Secondary schools in Alberta, Canada. A total of 4936 students from grades 7 to 10. The presence of beverage-vending machines in schools was associated with the weight status of students. The presence of snack-vending machines and logos was associated with students' frequency of consuming vended goods. The presence of snack-vending machines and logos was associated with the frequency of salty snack consumption. The reported presence of snack- and beverage-vending machines and logos in schools is related to some indices of weight status, diet and meal behaviours but not to others. The present study supported the general hypothesis that the presence of vending machines in schools may affect students' weight through increased consumption of vended goods, but notes that the frequency of 'junk' food consumption does not seem to be related to the presence of vending machines, perhaps reflecting the ubiquity of these foods in the daily lives of students.
Parental attitudes towards soft drink vending machines in high schools.
Hendel-Paterson, Maia; French, Simone A; Story, Mary
2004-10-01
Soft drink vending machines are available in 98% of US high schools. However, few data are available about parents' opinions regarding the availability of soft drink vending machines in schools. Six focus groups with 33 parents at three suburban high schools were conducted to describe the perspectives of parents regarding soft drink vending machines in their children's high school. Parents viewed the issue of soft drink vending machines as a matter of their children's personal choice more than as an issue of a healthful school environment. However, parents were unaware of many important details about the soft drink vending machines in their children's school, such as the number and location of machines, hours of operation, types of beverages available, or whether the school had contracts with soft drink companies. Parents need more information about the number of soft drink vending machines at their children's school, the beverages available, the revenue generated by soft drink vending machine sales, and the terms of any contracts between the school and soft drink companies.
The desktop interface in intelligent tutoring systems
NASA Technical Reports Server (NTRS)
Baudendistel, Stephen; Hua, Grace
1987-01-01
The interface between an Intelligent Tutoring System (ITS) and the person being tutored is critical to the success of the learning process. If the interface to the ITS is confusing or non-supportive of the tutored domain, the effectiveness of the instruction will be diminished or lost entirely. Consequently, the interface to an ITS should be highly integrated with the domain to provide a robust and semantically rich learning environment. In building an ITS for ZetaLISP on a LISP Machine, a Desktop Interface was designed to support a programming learning environment. Using the bitmapped display, windows, and mouse, three desktops were designed to support self-study and tutoring of ZetaLISP. Through organization, well-defined boundaries, and domain support facilities, the desktops provide substantial flexibility and power for the student and facilitate learning ZetaLISP programming while screening the student from the complex LISP Machine environment. The student can concentrate on learning ZetaLISP programming and not on how to operate the interface or a LISP Machine.
Metaphor and Common-Sense Reasoning
1983-03-05
of attacking aircraft, the extent of physical damage, the emotional affect on audiences of theatrical productions, the amount of political muscle (to...information, simply by signailng his audience that information in the source dnmain is applicable to the target domain. Presumab;y the reader has a coherent...of the metahor expects that hi audience will all hav the tae opinion a to which of Laker’s features at* salient. Why certain features awe considered
Armed Forces and National Development in Korea
1988-12-01
2698 Naval Postgraduate School Monterey, CA 93943 7. Ha, Tae Hwan SMC 2588 Naval Postgraduate School Monterey, CA 93943 8. Kim , Dong Hui SMC 2610 Naval...an agreement between the Provisional Government leader Kim Ku and Chiang Kai-Shek. Many of these Korean officers, mostly the Japanese-trained, played...when the military took over the corrupt and inefficient government [Ref. 6:p. 36]. Kim said that the military assumption of power in 1961 was
Figural Aftereffects: An Explanation in Terms of Multiple Mechanisms in the Human Visual System,
1983-04-19
increments. The width of the four TFs was held constant at 30 min (the width of the smallest IF) while tae height varied from 15 ( TF1 ) to 60 (TF4...in width from 15 ( TF1 ) to 30 (TF4) Min. of arc in 5 min. increments and were oriented at 00, or vertical. A range of 900 to 1800 min 2 of visual angle
South Korea’s Commercial Liberal Approach to Security
2002-03-01
Won -Keun Choi . “New Challenges Of The Korean Economy.” The Journal of East Asian Affairs. Vol.XIV, No.2, Fall/Winter 2000,pp...of Defense Analysis, Vol. VIII, No.2, Winter 1996, pp 223-268. Ko, Jong-Moon, Yung-Il So, Won -Keun Choi . “New Challenges Of The... Seung , Ho Joo and Tae Hwan Kwak, eds. Huntington: Nova Science Publishers, Inc, 2001, pp 185. 5 made by the South Korean
Automatic Analyzers and Signal Indicators of Toxic and Dangerously Explosive Substances in Air,
1980-01-09
of air are used also thermo- conductometry and electroconductometric methods. The thermo- conductometry method of analysis is based on a change of the... conductometry gas analyzers is very limited and is reduced in essence to the analysis of two-component mixtures or multicomponent ones, all whose...differs. Rain disadvantage in tae tnormo- conductometry gas analyzers - increased sensitivity to a change in the ambient conditions, in consequence of
1986-03-31
Weinberger to open negotiations over the issue. North Korean Foreign Minister Kim Yong -nam expressed his willingness to comply with the U.S...dummy? The ruling party’s proposal in itself certainly is a change, but it is not reasonable. After a few consultations with Kim Tae-chung, Kim Yong -sam...Hungsadan Hall, making a. human tide which paralyzed traffic. As the crowd was growing out of their control, Yi Min-u and Kim Yong -sam stopped to
Korean Affairs Report No. 308.
1983-09-14
Assemblyman Kim Yong -mok said: A tax evasion incident has finally turned into the fraud of the century. National Assemblyman Kim Chae- yong said...Pong Tu-hwan, Chairman of the National Assembly Foreign Affairs Committee, and Kim Yong -tae, the DJP spokesman, answering a reporter’s question on...debts of the Myongsong Group not been mentioned in the tax investigation report?" Representatives Kim Chae- yong , Han Kwang-ok and Hong Sa-tok from the
2013-05-28
those of the support vector machine and relevance vector machine, and the model runs more quickly than the other algorithms . When one class occurs...incremental support vector machine algorithm for online learning when fewer than 50 data points are available. (a) Papers published in peer-reviewed journals...learning environments, where data processing occurs one observation at a time and the classification algorithm improves over time with new
Non-equilibrium quantum heat machines
NASA Astrophysics Data System (ADS)
Alicki, Robert; Gelbwaser-Klimovsky, David
2015-11-01
Standard heat machines (engine, heat pump, refrigerator) are composed of a system (working fluid) coupled to at least two equilibrium baths at different temperatures and periodically driven by an external device (piston or rotor) sometimes called the work reservoir. The aim of this paper is to go beyond this scheme by considering environments which are stationary but cannot be decomposed into a few baths at thermal equilibrium. Such situations are important, for example in solar cells, chemical machines in biology, various realizations of laser cooling or nanoscopic machines driven by laser radiation. We classify non-equilibrium baths depending on their thermodynamic behavior and show that the efficiency of heat machines powered by them is limited by the generalized Carnot bound.
Bishop, Christopher M
2013-02-13
Several decades of research in the field of machine learning have resulted in a multitude of different algorithms for solving a broad range of problems. To tackle a new application, a researcher typically tries to map their problem onto one of these existing methods, often influenced by their familiarity with specific algorithms and by the availability of corresponding software implementations. In this study, we describe an alternative methodology for applying machine learning, in which a bespoke solution is formulated for each new application. The solution is expressed through a compact modelling language, and the corresponding custom machine learning code is then generated automatically. This model-based approach offers several major advantages, including the opportunity to create highly tailored models for specific scenarios, as well as rapid prototyping and comparison of a range of alternative models. Furthermore, newcomers to the field of machine learning do not have to learn about the huge range of traditional methods, but instead can focus their attention on understanding a single modelling environment. In this study, we show how probabilistic graphical models, coupled with efficient inference algorithms, provide a very flexible foundation for model-based machine learning, and we outline a large-scale commercial application of this framework involving tens of millions of users. We also describe the concept of probabilistic programming as a powerful software environment for model-based machine learning, and we discuss a specific probabilistic programming language called Infer.NET, which has been widely used in practical applications.
Bishop, Christopher M.
2013-01-01
Several decades of research in the field of machine learning have resulted in a multitude of different algorithms for solving a broad range of problems. To tackle a new application, a researcher typically tries to map their problem onto one of these existing methods, often influenced by their familiarity with specific algorithms and by the availability of corresponding software implementations. In this study, we describe an alternative methodology for applying machine learning, in which a bespoke solution is formulated for each new application. The solution is expressed through a compact modelling language, and the corresponding custom machine learning code is then generated automatically. This model-based approach offers several major advantages, including the opportunity to create highly tailored models for specific scenarios, as well as rapid prototyping and comparison of a range of alternative models. Furthermore, newcomers to the field of machine learning do not have to learn about the huge range of traditional methods, but instead can focus their attention on understanding a single modelling environment. In this study, we show how probabilistic graphical models, coupled with efficient inference algorithms, provide a very flexible foundation for model-based machine learning, and we outline a large-scale commercial application of this framework involving tens of millions of users. We also describe the concept of probabilistic programming as a powerful software environment for model-based machine learning, and we discuss a specific probabilistic programming language called Infer.NET, which has been widely used in practical applications. PMID:23277612
Vending machine assessment methodology. A systematic review.
Matthews, Melissa A; Horacek, Tanya M
2015-07-01
The nutritional quality of food and beverage products sold in vending machines has been implicated as a contributing factor to the development of an obesogenic food environment. How comprehensive, reliable, and valid are the current assessment tools for vending machines to support or refute these claims? A systematic review was conducted to summarize, compare, and evaluate the current methodologies and available tools for vending machine assessment. A total of 24 relevant research studies published between 1981 and 2013 met inclusion criteria for this review. The methodological variables reviewed in this study include assessment tool type, study location, machine accessibility, product availability, healthfulness criteria, portion size, price, product promotion, and quality of scientific practice. There were wide variations in the depth of the assessment methodologies and product healthfulness criteria utilized among the reviewed studies. Of the reviewed studies, 39% evaluated machine accessibility, 91% evaluated product availability, 96% established healthfulness criteria, 70% evaluated portion size, 48% evaluated price, 52% evaluated product promotion, and 22% evaluated the quality of scientific practice. Of all reviewed articles, 87% reached conclusions that provided insight into the healthfulness of vended products and/or vending environment. Product healthfulness criteria and complexity for snack and beverage products was also found to be variable between the reviewed studies. These findings make it difficult to compare results between studies. A universal, valid, and reliable vending machine assessment tool that is comprehensive yet user-friendly is recommended. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Skrzypek, Josef; Mesrobian, Edmond; Gungner, David J.
1989-03-01
The development of autonomous land vehicles (ALV) capable of operating in an unconstrained environment has proven to be a formidable research effort. The unpredictability of events in such an environment calls for the design of a robust perceptual system, an impossible task requiring the programming of a system bases on the expectation of future, unconstrained events. Hence, the need for a "general purpose" machine vision system that is capable of perceiving and understanding images in an unconstrained environment in real-time. The research undertaken at the UCLA Machine Perception Laboratory addresses this need by focusing on two specific issues: 1) the long term goals for machine vision research as a joint effort between the neurosciences and computer science; and 2) a framework for evaluating progress in machine vision. In the past, vision research has been carried out independently within different fields including neurosciences, psychology, computer science, and electrical engineering. Our interdisciplinary approach to vision research is based on the rigorous combination of computational neuroscience, as derived from neurophysiology and neuropsychology, with computer science and electrical engineering. The primary motivation behind our approach is that the human visual system is the only existing example of a "general purpose" vision system and using a neurally based computing substrate, it can complete all necessary visual tasks in real-time.
NASA Astrophysics Data System (ADS)
Wang, Ruichen; Lu, Jingyang; Xu, Yiran; Shen, Dan; Chen, Genshe; Pham, Khanh; Blasch, Erik
2018-05-01
Due to the progressive expansion of public mobile networks and the dramatic growth of the number of wireless users in recent years, researchers are motivated to study the radio propagation in urban environments and develop reliable and fast path loss prediction models. During last decades, different types of propagation models are developed for urban scenario path loss predictions such as the Hata model and the COST 231 model. In this paper, the path loss prediction model is thoroughly investigated using machine learning approaches. Different non-linear feature selection methods are deployed and investigated to reduce the computational complexity. The simulation results are provided to demonstratethe validity of the machine learning based path loss prediction engine, which can correctly determine the signal propagation in a wireless urban setting.
de Beer, D A H; Nesbitt, F D; Bell, G T; Rapuleng, A
2017-04-01
The Universal Anaesthesia Machine has been developed as a complete anaesthesia workstation for use in low- and middle-income countries, where the provision of safe general anaesthesia is often compromised by unreliable supply of electricity and anaesthetic gases. We performed a functional and clinical assessment of this anaesthetic machine, with particular reference to novel features and functioning in the intended environment. The Universal Anaesthesia Machine was found to be reliable, safe and consistent across a range of tests during targeted functional testing. © 2016 The Association of Anaesthetists of Great Britain and Ireland.
Block-Module Electric Machines of Alternating Current
NASA Astrophysics Data System (ADS)
Zabora, I.
2018-03-01
The paper deals with electric machines having active zone based on uniform elements. It presents data on disk-type asynchronous electric motors with short-circuited rotors, where active elements are made by integrated technique that forms modular elements. Photolithography, spraying, stamping of windings, pressing of core and combined methods are utilized as the basic technological approaches of production. The constructions and features of operation for new electric machine - compatible electric machines-transformers are considered. Induction motors are intended for operation in hermetic plants with extreme conditions surrounding gas, steam-to-gas and liquid environment at a high temperature (to several hundred of degrees).
NASA Astrophysics Data System (ADS)
Hiatt, Keith L.; Rash, Clarence E.
2011-06-01
Background: Army Aviators rely on the ANVIS for night operations. Human factors literature notes that the ANVIS man-machine interface results in reports of visual and spinal complaints. This is the first study that has looked at these issues in the much harsher combat environment. Last year, the authors reported on the statistically significant (p<0.01) increased complaints of visual discomfort, degraded visual cues, and incidence of static and dynamic visual illusions in the combat environment [Proc. SPIE, Vol. 7688, 76880G (2010)]. In this paper we present the findings regarding increased spinal complaints and other man-machine interface issues found in the combat environment. Methods: A survey was administered to Aircrew deployed in support of Operation Enduring Freedom (OEF). Results: 82 Aircrew (representing an aggregate of >89,000 flight hours of which >22,000 were with ANVIS) participated. Analysis demonstrated high complaints of almost all levels of back and neck pain. Additionally, the use of body armor and other Aviation Life Support Equipment (ALSE) caused significant ergonomic complaints when used with ANVIS. Conclusions: ANVIS use in a combat environment resulted in higher and different types of reports of spinal symptoms and other man-machine interface issues over what was previously reported. Data from this study may be more operationally relevant than that of the peacetime literature as it is derived from actual combat and not from training flights, and it may have important implications about making combat predictions based on performance in training scenarios. Notably, Aircrew remarked that they could not execute the mission without ANVIS and ALSE and accepted the degraded ergonomic environment.
Environmental concept for engineering software on MIMD computers
NASA Technical Reports Server (NTRS)
Lopez, L. A.; Valimohamed, K.
1989-01-01
The issues related to developing an environment in which engineering systems can be implemented on MIMD machines are discussed. The problem is presented in terms of implementing the finite element method under such an environment. However, neither the concepts nor the prototype implementation environment are limited to this application. The topics discussed include: the ability to schedule and synchronize tasks efficiently; granularity of tasks; load balancing; and the use of a high level language to specify parallel constructs, manage data, and achieve portability. The objective of developing a virtual machine concept which incorporates solutions to the above issues leads to a design that can be mapped onto loosely coupled, tightly coupled, and hybrid systems.
Simunovic, Vesna; Müller, Rolf
2007-07-23
It has been proposed that two acyl carrier proteins (ACPs)-TaB and TaE--and two 3-hydroxy-3-methylglutaryl synthases (HMGSs)--TaC and TaF--could constitute two functional ACP-HMGS pairs (TaB/TaC and TaE/TaF) responsible for the incorporation of acetate and propionate units into the myxovirescin A scaffold, leading to the formation of beta-methyl and beta-ethyl groups, respectively. It has been suggested that three more proteins--TaX and TaY, which are members of the superfamily of enoyl-CoA hydratases (ECHs), and a variant ketosynthase (KS) TaK--are shared between two ACP-HMGS pairs, to give the complete set of enzymes required to perform the beta-alkylations. The beta-methyl branch is presumably further hydroxylated (by TaH) and methylated to produce the methoxymethyl group observed in myxovirescin A. To substantiate this hypothesis, a series of gene-deletion mutants were created, and the effects of these mutations on myxovirescin production were examined. As predicted, DeltataB and DeltataE ACP mutants revealed similar phenotypes to their associated HMGS mutants DeltataC and DeltataF, respectively, thus providing direct evidence for the role of TaE/TaF in the formation of the beta-ethyl branch and implying a role for TaB/TaC in the formation of the beta-methyl group. Production of myxovirescin A was dramatically reduced in a DeltataK mutant and abolished in both the DeltataX and the DeltataY mutant backgrounds. Analysis of a DeltataH mutant confirmed the role of the cytochrome P450 TaH in hydroxylation of the beta-methyl group. Taken together, these experiments support a model in which the discrete ACPs TaB and TaE are compatible only with their associated HMGSs TaC and TaF, respectively, and function in a substrate-specific manner. Both TaB and TaC are essential for myxovirescin production, and the TaB/TaC pair can rescue antibiotic production in the absence of either TaE or TaF. Finally, the reduced level of myxovirescin production in the DeltataE mutant, relative to the DeltataF strain, suggests an additional function of the TaE ACP.
Yip, Y B; Tse, Hing-Min Sonny; Wu, Ka Kalina
2007-02-01
To compare the efficacy of combined transcutaneous acupoint electrical stimulation (TAES) and electromagnetic millimeter wave (EMMW) therapy as an add-on treatment for pain relief and physical functional activity enhancement among adults with sub-acute non-specific spinal pain in either the low back or neck. A non-blinded study with data obtained before, immediate, one week and three months after intervention. The Telehealth Clinic and Community Centre, Hong Kong. Forty-seven subjects with either sub-acute neck or low back pain. Subjects were randomly allocated to either an intervention group (n=23) or a control group (n=24). These groups were then divided into subgroups according to the site of their spinal pain-neck or back. The intervention group had eight treatments over a three-week period of TAES and EMMW. Changes from baseline to the end of treatment were assessed at intervals of one week and three months on either neck or low back pain intensity [by Visual Analogue Scale (VAS)]; stiffness level; stress level; neck or low back lateral flexion and forward flexion in cm, and interference with daily activities. The baseline VAS scores for the intervention and control groups were 5.34 and 5.18 out of 10, respectively (P value=0.77). At the one week and three month assessments, there were no significant differences between the groups-VAS (P value=0.09 and 0.27, respectively). A further subgroup of chronic pain sufferers (n=31) was identified and these had significantly reduced pain intensity at the one week assessment (P value=0.04) but this was not sustained at post three months after treatment (P value=0.15). Improvements in stiffness level, stress level, and functional disability level in the intervention group were not significant. Our study shows that there was a reduction in pain intensity, stress and stiffness level immediately after the eight sessions of treatment (TAES and EMMW), though the effect is not sustained after a week. No pain relief was found with the neck pain subgroup. However, the reduction in subjective average pain intensity among the chronic pain subgroup was sustained at the post one week assessment for the intervention group but not at the post three month assessment.
Energetic particles in spherical tokamak plasmas
McClements, K. G.; Fredrickson, E. D.
2017-03-21
Spherical tokamaks (STs) typically have lower magnetic fields than conventional tokamaks, but similar mass densities. Suprathermal ions with relatively modest energies, in particular beam-injected ions, consequently have speeds close to or exceeding the Alfvén velocity, and can therefore excite a range of Alfvénic instabilities which could be driven by (and affect the behaviour of) fusion α-particles in a burning plasma. STs heated with neutral beams, including the small tight aspect ratio tokamak (START), the mega amp spherical tokamak (MAST), the national spherical torus experiment (NSTX) and Globus-M, have thus provided an opportunity to study toroidal Alfvén eigenmodes (TAEs), together withmore » higher frequency global Alfvén eigenmodes (GAEs) and compressional Alfvén eigenmodes (CAEs), which could affect beam current drive and channel fast ion energy into bulk ions in future devices. In NSTX GAEs were correlated with a degradation of core electron energy confinement. In MAST pulses with reduced magnetic field, CAEs were excited across a wide range of frequencies, extending to the ion cyclotron range, but were suppressed when hydrogen was introduced to the deuterium plasma, apparently due to mode conversion at ion–ion hybrid resonances. At lower frequencies fishbone instabilities caused fast particle redistribution in some MAST and NSTX pulses, but this could be avoided by moving the neutral beam line away from the magnetic axis or by operating the plasma at either high density or elevated safety factor. Fast ion redistribution has been observed during GAE avalanches on NSTX, while in both NSTX and MAST fast ions were transported by saturated kink modes, sawtooth crashes, resonant magnetic perturbations and TAEs. The energy dependence of fast ion redistribution due to both sawteeth and TAEs has been studied in Globus-M. High energy charged fusion products are unconfined in present-day STs, but have been shown in MAST to provide a useful diagnostic of beam ion behaviour, supplementing the information provided by neutron detectors. In MAST electrons were accelerated to highly suprathermal energies as a result of edge localised modes, while in both MAST and NSTX ions were accelerated due to internal reconnection events. Lastly, ion acceleration has also been observed during merging-compression start-up in MAST.« less
Tacher, Vania; Duran, Rafael; Lin, MingDe; Sohn, Jae Ho; Sharma, Karun V.; Wang, Zhijun; Chapiro, Julius; Gacchina Johnson, Carmen; Bhagat, Nikhil; Dreher, Matthew R.; Schäfer, Dirk; Woods, David L.; Lewis, Andrew L.; Tang, Yiqing; Grass, Michael; Wood, Bradford J.
2016-01-01
Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70–150-μm radiopaque microspheres in saline (radiopaque microsphere group), 70–150-μm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70–150-μm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. © RSNA, 2015 PMID:26678453
33 CFR 157.124 - COW tank washing machines.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false COW tank washing machines. 157... (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157...
Far Travelers: The Exploring Machines.
ERIC Educational Resources Information Center
Nicks, Oran W.
The National Aeronautics and Space Administration (NASA) program of lunar and planetary exploration produced a flood of scientific information about the moon, planets and the environment of interplanetary space. This book is an account of the people, machines, and the events of this scientific enterprise. It is a story of organizations,…
ERIC Educational Resources Information Center
Nehm, Ross H.; Ha, Minsu; Mayfield, Elijah
2012-01-01
This study explored the use of machine learning to automatically evaluate the accuracy of students' written explanations of evolutionary change. Performance of the Summarization Integrated Development Environment (SIDE) program was compared to human expert scoring using a corpus of 2,260 evolutionary explanations written by 565 undergraduate…
Fantastic Journey through Minds and Machines.
ERIC Educational Resources Information Center
Muir, Michael
Intended for learners with a basic familiarity with the Logo programming language, this manual is designed to introduce them to artificial intelligence and enhance their programming capabilities. Nine chapters discuss the following features of Logo: (1) MAZE.MASTER, a look at robots and how sensors make machines aware of their environment; (2)…
NASA Astrophysics Data System (ADS)
Vogelsberg, Cortnie Sue
Amphidynamic crystals are an extremely promising platform for the development of artificial molecular machines and stimuli-responsive materials. In analogy to skeletal muscle, their function will rely upon the collective operation of many densely packed molecular machines (i.e. actin-bound myosin) that are self-assembled in a highly organized anisotropic medium. By choosing lattice-forming elements and moving "parts" with specific functionalities, individual molecular machines may be synthesized and self-assembled in order to carry out desirable functions. In recent years, efforts in the design of amphidynamic materials based on molecular gyroscopes and compasses have shown that a certain amount of free volume is essential to facilitate internal rotation and reorientation within a crystal. In order to further establish structure/function relationships to advance the development of increasingly complex molecular machinery, molecular rotors and a molecular "spinning" top were synthesized and incorporated into a variety of solid-state architectures with different degrees of periodicity, dimensionality, and free volume. Specifically, lamellar molecular crystals, hierarchically ordered periodic mesoporous organosilicas, and metal-organic frameworks were targeted for the development of solid-state molecular machines. Using an array of solid-state nuclear magnetic resonance spectroscopy techniques, the dynamic properties of these novel molecular machine assemblies were determined and correlated with their corresponding structural features. It was found that architecture type has a profound influence on functional dynamics. The study of layered molecular crystals, composed of either molecular rotors or "spinning" tops, probed functional dynamics within dense, highly organized environments. From their study, it was discovered that: 1) crystallographically distinct sites may be utilized to differentiate machine function, 2) halogen bonding interactions are sufficiently strong to direct an assembly of molecular machines, 3) the relative flexibility of the crystal environment proximate to a dynamic component may have a significant effect on its function, and, 4) molecular machines, which possess both solid-state photochemical reactivity and dynamics may show complex reaction kinetics if the correlation time of the dynamic process and the lifetime of the excited state occur on the same time scale and the dynamic moiety inherently participates as a reaction intermediate. The study of periodic mesoporous organosilica with hierarchical order probed molecular dynamics within 2D layers of molecular rotors, organized in only one dimension and with ca. 50% exposed to the mesopore free volume. From their study, it was discovered that: 1) molecular rotors, which comprise the layers of the mesopore walls, form a 2D rotational glass, 2) rotator dynamics within the 2D rotational glass undergo a transition to a 2D rotational fluid, and, 3) a 2D rotational glass transition may be exploited to develop hyper-sensitive thermally activated molecular machines. The study of a metal-organic framework assembled from molecular rotors probed dynamics in a periodic three-dimensional free-volume environment, without the presence of close contacts. From the study of this solid-state material, it was determined that: 1) the intrinsic electronic barrier is one of the few factors, which may affect functional dynamics in a true free-volume environment, and, 2) molecular machines with dynamic barriers <
Software platform virtualization in chemistry research and university teaching
2009-01-01
Background Modern chemistry laboratories operate with a wide range of software applications under different operating systems, such as Windows, LINUX or Mac OS X. Instead of installing software on different computers it is possible to install those applications on a single computer using Virtual Machine software. Software platform virtualization allows a single guest operating system to execute multiple other operating systems on the same computer. We apply and discuss the use of virtual machines in chemistry research and teaching laboratories. Results Virtual machines are commonly used for cheminformatics software development and testing. Benchmarking multiple chemistry software packages we have confirmed that the computational speed penalty for using virtual machines is low and around 5% to 10%. Software virtualization in a teaching environment allows faster deployment and easy use of commercial and open source software in hands-on computer teaching labs. Conclusion Software virtualization in chemistry, mass spectrometry and cheminformatics is needed for software testing and development of software for different operating systems. In order to obtain maximum performance the virtualization software should be multi-core enabled and allow the use of multiprocessor configurations in the virtual machine environment. Server consolidation, by running multiple tasks and operating systems on a single physical machine, can lead to lower maintenance and hardware costs especially in small research labs. The use of virtual machines can prevent software virus infections and security breaches when used as a sandbox system for internet access and software testing. Complex software setups can be created with virtual machines and are easily deployed later to multiple computers for hands-on teaching classes. We discuss the popularity of bioinformatics compared to cheminformatics as well as the missing cheminformatics education at universities worldwide. PMID:20150997
Software platform virtualization in chemistry research and university teaching.
Kind, Tobias; Leamy, Tim; Leary, Julie A; Fiehn, Oliver
2009-11-16
Modern chemistry laboratories operate with a wide range of software applications under different operating systems, such as Windows, LINUX or Mac OS X. Instead of installing software on different computers it is possible to install those applications on a single computer using Virtual Machine software. Software platform virtualization allows a single guest operating system to execute multiple other operating systems on the same computer. We apply and discuss the use of virtual machines in chemistry research and teaching laboratories. Virtual machines are commonly used for cheminformatics software development and testing. Benchmarking multiple chemistry software packages we have confirmed that the computational speed penalty for using virtual machines is low and around 5% to 10%. Software virtualization in a teaching environment allows faster deployment and easy use of commercial and open source software in hands-on computer teaching labs. Software virtualization in chemistry, mass spectrometry and cheminformatics is needed for software testing and development of software for different operating systems. In order to obtain maximum performance the virtualization software should be multi-core enabled and allow the use of multiprocessor configurations in the virtual machine environment. Server consolidation, by running multiple tasks and operating systems on a single physical machine, can lead to lower maintenance and hardware costs especially in small research labs. The use of virtual machines can prevent software virus infections and security breaches when used as a sandbox system for internet access and software testing. Complex software setups can be created with virtual machines and are easily deployed later to multiple computers for hands-on teaching classes. We discuss the popularity of bioinformatics compared to cheminformatics as well as the missing cheminformatics education at universities worldwide.
Atomic Layer Deposition Enabled Interconnect Technology for Vertical Nanowire Arrays
2009-06-01
Diodes”, Nano Lett., Vol. 5, No. 11, 2005. [5] Hwa-Mok Kim, Tae Won Kang and Kwan Soo Chung,“Nanoscale Ultraviolet-Light- Emitting Diodes Using Wide...Bandgap Gallium Nitride Nanorods”, Adv. Materi. 2003, 15, No. 7-8. [6] Candace K. Chan, Hailin Peng, Gao Liu, Kevin McIlwrath, Xiao Feng Zhang...Coatings”Adv. Mater. (Weinheim, Ger.) 19, 1801 2007. [13] Candace K. Chan, Hailin Peng, Gao Liu, Kevin McIlwrath, Xiao Feng Zhang, Robert A. Huggins
1991-04-01
Navy Personnel Research and Development Center San Diego, California 92152-680 TN-91-11 April 1991 AD-A236 401 Troubleshooting Assessment and...Navy Personnel Research and Development Center San Diego, California 92152-6800 REPORT DOCUMENTATION PAGE J on Appved I CN ft. M 4- in da Pubh npon...ADDRESSES) 8. PERFORMING ORGANIZATION Navy Personnel Research and Development Center REPORT NUMBER San Diego, Ca’ifomia 92152-6800 NPRDC-TN-91-11 9
The Cause of Hypoglycemia in Dogs Exposed to Heat
1959-06-01
the In 2 previously unused dogs we decided respiratory alkalosis . In a series of 11 ex- to produce a combined metabolic and respira- I periments the...Just above control metabolic alkalosis with a respiratory alkalosis . values at the end of 4 1hours. Evidently acid The animal could not satisfactorily...While a combined respiratory and wi~abolic alkalosis is a serfius strain on the regu-tory 1.T tae Insulin a do uuisllke ato NOl mechanism, some animals
Intelligent image processing for machine safety
NASA Astrophysics Data System (ADS)
Harvey, Dennis N.
1994-10-01
This paper describes the use of intelligent image processing as a machine guarding technology. One or more color, linear array cameras are positioned to view the critical region(s) around a machine tool or other piece of manufacturing equipment. The image data is processed to provide indicators of conditions dangerous to the equipment via color content, shape content, and motion content. The data from these analyses is then sent to a threat evaluator. The purpose of the evaluator is to determine if a potentially machine-damaging condition exists based on the analyses of color, shape, and motion, and on `knowledge' of the specific environment of the machine. The threat evaluator employs fuzzy logic as a means of dealing with uncertainty in the vision data.
Wang, Xiao-Ling; Ding, Zhong-Yang; Liu, Gao-Qiang; Yang, Hailong; Zhou, Guo-Ying
2016-10-20
Triterpene acids (TAs) are the major bioactive constituents in the medicinal fungus Ganoderma lingzhi . However, fermentative production of TAs has not been optimized for commercial use, and whether the TAs isolated from G. lingzhi submerged culture mycelia possess antitumor activity needs to be further proven. In this study, enhanced TA yield and productivity were attained with G. lingzhi using response surface methodology. The interactions of three variables were studied using a Box-Benhnken design, namely initial pH, dissolved oxygen (DO) and fermentation temperature. The optimum conditions were an initial pH of 5.9, 20.0% DO and 28.6 °C. These conditions resulted in a TA yield of 308.1 mg/L in a 5-L stirred bioreactor. Furthermore, the optimized conditions were then successfully scaled up to a production scale of 200 L, and maximum TA production and productivity of 295.3 mg/L and 49.2 mg/L/day were achieved, which represented 80.9% and 111.5% increases, respectively, compared with the non-optimized conditions. Additionally, the triterpene acid extract (TAE) from G. lingzhi mycelia was found to be cytotoxic to the SMMC-7721 and SW620 cell lines in vitro, and the TAE exhibited dose-dependent antitumor activity against the solid tumor sarcoma 180 in vivo. Chemical analysis revealed that the key active triterpene compounds, ganoderic acid T and ganoderic acid Me, predominated in the extract.
Wheel inspection system environment.
DOT National Transportation Integrated Search
2008-11-18
International Electronic Machines Corporation (IEM) has developed and is now marketing a state-of-the-art Wheel Inspection System Environment (WISE). WISE provides wheel profile and dimensional measurements, i.e. rim thickness, flange height, flange ...
Respiratory symptoms and conditions related to occupational exposures in machine shops.
Jaakkola, Maritta S; Suuronen, Katri; Luukkonen, Ritva; Järvelä, Merja; Tuomi, Timo; Alanko, Kristiina; Mäkelä, Erja A; Jolanki, Riitta
2009-01-01
Since there are few data on the effects of metalworking in populations representing a variety of metal companies or on dose-response relationships concerning metalworking, this study investigated the relationship between occupational exposures in machine shops and the occurrence of upper and lower respiratory symptoms, asthma, and chronic bronchitis. A cross-sectional study of 726 male machine workers and 84 male office workers from 64 companies was conducted in southern Finland. All of the participants filled out a questionnaire, and aerosol measurements were performed in 57 companies. Exposure to metalworking fluids (MWF) showed a greater risk [odds ratio (OR)>or=2) for upper-airway symptoms, cough, breathlessness, and current asthma than exposures in office work did. Exposure to aerosol levels above the median (>or=0.17 mg/m3 in the general workshop air) was related to an increased risk (OR>or=2) of nasal and throat symptoms, cough, wheezing, breathlessness, chronic bronchitis, and current asthma. Machine workers with a job history of >or=15 years experienced increased throat symptoms, cough, and chronic bronchitis. This large study representing machine shops in southern Finland showed that machine workers experience increased nasal and throat symptoms, cough, wheezing, breathlessness, and asthma even in environments with exposure levels below the current occupational exposure limit for oil mists. The study suggests that improving machine shop environments could benefit the health of this workforce. It also suggests that it is time to consider reducing the current Finnish occupational exposure limit for oil mist or introducing the use of other health-relevant indicators of exposure.
Towards a generalized energy prediction model for machine tools
Bhinge, Raunak; Park, Jinkyoo; Law, Kincho H.; Dornfeld, David A.; Helu, Moneer; Rachuri, Sudarsan
2017-01-01
Energy prediction of machine tools can deliver many advantages to a manufacturing enterprise, ranging from energy-efficient process planning to machine tool monitoring. Physics-based, energy prediction models have been proposed in the past to understand the energy usage pattern of a machine tool. However, uncertainties in both the machine and the operating environment make it difficult to predict the energy consumption of the target machine reliably. Taking advantage of the opportunity to collect extensive, contextual, energy-consumption data, we discuss a data-driven approach to develop an energy prediction model of a machine tool in this paper. First, we present a methodology that can efficiently and effectively collect and process data extracted from a machine tool and its sensors. We then present a data-driven model that can be used to predict the energy consumption of the machine tool for machining a generic part. Specifically, we use Gaussian Process (GP) Regression, a non-parametric machine-learning technique, to develop the prediction model. The energy prediction model is then generalized over multiple process parameters and operations. Finally, we apply this generalized model with a method to assess uncertainty intervals to predict the energy consumed to machine any part using a Mori Seiki NVD1500 machine tool. Furthermore, the same model can be used during process planning to optimize the energy-efficiency of a machining process. PMID:28652687
Towards a generalized energy prediction model for machine tools.
Bhinge, Raunak; Park, Jinkyoo; Law, Kincho H; Dornfeld, David A; Helu, Moneer; Rachuri, Sudarsan
2017-04-01
Energy prediction of machine tools can deliver many advantages to a manufacturing enterprise, ranging from energy-efficient process planning to machine tool monitoring. Physics-based, energy prediction models have been proposed in the past to understand the energy usage pattern of a machine tool. However, uncertainties in both the machine and the operating environment make it difficult to predict the energy consumption of the target machine reliably. Taking advantage of the opportunity to collect extensive, contextual, energy-consumption data, we discuss a data-driven approach to develop an energy prediction model of a machine tool in this paper. First, we present a methodology that can efficiently and effectively collect and process data extracted from a machine tool and its sensors. We then present a data-driven model that can be used to predict the energy consumption of the machine tool for machining a generic part. Specifically, we use Gaussian Process (GP) Regression, a non-parametric machine-learning technique, to develop the prediction model. The energy prediction model is then generalized over multiple process parameters and operations. Finally, we apply this generalized model with a method to assess uncertainty intervals to predict the energy consumed to machine any part using a Mori Seiki NVD1500 machine tool. Furthermore, the same model can be used during process planning to optimize the energy-efficiency of a machining process.
NASA Technical Reports Server (NTRS)
Byman, J. E.
1985-01-01
A brief history of aircraft production techniques is given. A flexible machining cell is then described. It is a computer controlled system capable of performing 4-axis machining part cleaning, dimensional inspection and materials handling functions in an unmanned environment. The cell was designed to: allow processing of similar and dissimilar parts in random order without disrupting production; allow serial (one-shipset-at-a-time) manufacturing; reduce work-in-process inventory; maximize machine utilization through remote set-up; maximize throughput and minimize labor.
Automated fiber pigtailing machine
Strand, Oliver T.; Lowry, Mark E.
1999-01-01
The Automated Fiber Pigtailing Machine (AFPM) aligns and attaches optical fibers to optoelectonic (OE) devices such as laser diodes, photodiodes, and waveguide devices without operator intervention. The so-called pigtailing process is completed with sub-micron accuracies in less than 3 minutes. The AFPM operates unattended for one hour, is modular in design and is compatible with a mass production manufacturing environment. This machine can be used to build components which are used in military aircraft navigation systems, computer systems, communications systems and in the construction of diagnostics and experimental systems.
Adapting human-machine interfaces to user performance.
Danziger, Zachary; Fishbach, Alon; Mussa-Ivaldi, Ferdinando A
2008-01-01
The goal of this study was to create and examine machine learning algorithms that adapt in a controlled and cadenced way to foster a harmonious learning environment between the user of a human-machine interface and the controlled device. In this experiment, subjects' high-dimensional finger motions remotely controlled the joint angles of a simulated planar 2-link arm, which was used to hit targets on a computer screen. Subjects were required to move the cursor at the endpoint of the simulated arm.
Parallel machine architecture and compiler design facilities
NASA Technical Reports Server (NTRS)
Kuck, David J.; Yew, Pen-Chung; Padua, David; Sameh, Ahmed; Veidenbaum, Alex
1990-01-01
The objective is to provide an integrated simulation environment for studying and evaluating various issues in designing parallel systems, including machine architectures, parallelizing compiler techniques, and parallel algorithms. The status of Delta project (which objective is to provide a facility to allow rapid prototyping of parallelized compilers that can target toward different machine architectures) is summarized. Included are the surveys of the program manipulation tools developed, the environmental software supporting Delta, and the compiler research projects in which Delta has played a role.
The remapping of space in motor learning and human-machine interfaces
Mussa-Ivaldi, F.A.; Danziger, Z.
2009-01-01
Studies of motor adaptation to patterns of deterministic forces have revealed the ability of the motor control system to form and use predictive representations of the environment. One of the most fundamental elements of our environment is space itself. This article focuses on the notion of Euclidean space as it applies to common sensory motor experiences. Starting from the assumption that we interact with the world through a system of neural signals, we observe that these signals are not inherently endowed with metric properties of the ordinary Euclidean space. The ability of the nervous system to represent these properties depends on adaptive mechanisms that reconstruct the Euclidean metric from signals that are not Euclidean. Gaining access to these mechanisms will reveal the process by which the nervous system handles novel sophisticated coordinate transformation tasks, thus highlighting possible avenues to create functional human-machine interfaces that can make that task much easier. A set of experiments is presented that demonstrate the ability of the sensory-motor system to reorganize coordination in novel geometrical environments. In these environments multiple degrees of freedom of body motions are used to control the coordinates of a point in a two-dimensional Euclidean space. We discuss how practice leads to the acquisition of the metric properties of the controlled space. Methods of machine learning based on the reduction of reaching errors are tested as a means to facilitate learning by adaptively changing he map from body motions to controlled device. We discuss the relevance of the results to the development of adaptive human machine interfaces and optimal control. PMID:19665553
Self-propulsion and interactions of catalytic particles in a chemically active medium.
Banigan, Edward J; Marko, John F
2016-01-01
Enzymatic "machines," such as catalytic rods or colloids, can self-propel and interact by generating gradients of their substrates. We theoretically investigate the behaviors of such machines in a chemically active environment where their catalytic substrates are continuously synthesized and destroyed, as occurs in living cells. We show how the kinetic properties of the medium modulate self-propulsion and pairwise interactions between machines, with the latter controlled by a tunable characteristic interaction range analogous to the Debye screening length in an electrolytic solution. Finally, we discuss the effective force arising between interacting machines and possible biological applications, such as partitioning of bacterial plasmids.
Job shop scheduling model for non-identic machine with fixed delivery time to minimize tardiness
NASA Astrophysics Data System (ADS)
Kusuma, K. K.; Maruf, A.
2016-02-01
Scheduling non-identic machines problem with low utilization characteristic and fixed delivery time are frequent in manufacture industry. This paper propose a mathematical model to minimize total tardiness for non-identic machines in job shop environment. This model will be categorized as an integer linier programming model and using branch and bound algorithm as the solver method. We will use fixed delivery time as main constraint and different processing time to process a job. The result of this proposed model shows that the utilization of production machines can be increase with minimal tardiness using fixed delivery time as constraint.
Modeling Stochastic Kinetics of Molecular Machines at Multiple Levels: From Molecules to Modules
Chowdhury, Debashish
2013-01-01
A molecular machine is either a single macromolecule or a macromolecular complex. In spite of the striking superficial similarities between these natural nanomachines and their man-made macroscopic counterparts, there are crucial differences. Molecular machines in a living cell operate stochastically in an isothermal environment far from thermodynamic equilibrium. In this mini-review we present a catalog of the molecular machines and an inventory of the essential toolbox for theoretically modeling these machines. The tool kits include 1), nonequilibrium statistical-physics techniques for modeling machines and machine-driven processes; and 2), statistical-inference methods for reverse engineering a functional machine from the empirical data. The cell is often likened to a microfactory in which the machineries are organized in modular fashion; each module consists of strongly coupled multiple machines, but different modules interact weakly with each other. This microfactory has its own automated supply chain and delivery system. Buoyed by the success achieved in modeling individual molecular machines, we advocate integration of these models in the near future to develop models of functional modules. A system-level description of the cell from the perspective of molecular machinery (the mechanome) is likely to emerge from further integrations that we envisage here. PMID:23746505
Intelligent excavator control system for lunar mining system
NASA Astrophysics Data System (ADS)
Lever, Paul J. A.; Wang, Fei-Yue
1995-01-01
A major benefit of utilizing local planetary resources is that it reduces the need and cost of lifting materials from the Earth's surface into Earth orbit. The location of the moon makes it an ideal site for harvesting the materials needed to assist space activities. Here, lunar excavation will take place in the dynamic unstructured lunar environment, in which conditions are highly variable and unpredictable. Autonomous mining (excavation) machines are necessary to remove human operators from this hazardous environment. This machine must use a control system structure that can identify, plan, sense, and control real-time dynamic machine movements in the lunar environment. The solution is a vision-based hierarchical control structure. However, excavation tasks require force/torque sensor feedback to control the excavation tool after it has penetrated the surface. A fuzzy logic controller (FLC) is used to interpret the forces and torques gathered from a bucket mounted force/torque sensor during excavation. Experimental results from several excavation tests using the FLC are presented here. These results represent the first step toward an integrated sensing and control system for a lunar mining system.
A SYSTEMS APPROACH UTILIZING GENERAL-PURPOSE AND SPECIAL-PURPOSE TEACHING MACHINES.
ERIC Educational Resources Information Center
SILVERN, LEONARD C.
IN ORDER TO IMPROVE THE EMPLOYEE TRAINING-EVALUATION METHOD, TEACHING MACHINES AND PERFORMANCE AIDS MUST BE PHYSICALLY AND OPERATIONALLY INTEGRATED INTO THE SYSTEM, THUS RETURNING TRAINING TO THE ACTUAL JOB ENVIRONMENT. GIVEN THESE CONDITIONS, TRAINING CAN BE MEASURED, CALIBRATED, AND CONTROLLED WITH RESPECT TO ACTUAL JOB PERFORMANCE STANDARDS AND…
Adaptive Learning Systems: Beyond Teaching Machines
ERIC Educational Resources Information Center
Kara, Nuri; Sevim, Nese
2013-01-01
Since 1950s, teaching machines have changed a lot. Today, we have different ideas about how people learn, what instructor should do to help students during their learning process. We have adaptive learning technologies that can create much more student oriented learning environments. The purpose of this article is to present these changes and its…
Study on intelligent processing system of man-machine interactive garment frame model
NASA Astrophysics Data System (ADS)
Chen, Shuwang; Yin, Xiaowei; Chang, Ruijiang; Pan, Peiyun; Wang, Xuedi; Shi, Shuze; Wei, Zhongqian
2018-05-01
A man-machine interactive garment frame model intelligent processing system is studied in this paper. The system consists of several sensor device, voice processing module, mechanical parts and data centralized acquisition devices. The sensor device is used to collect information on the environment changes brought by the body near the clothes frame model, the data collection device is used to collect the information of the environment change induced by the sensor device, voice processing module is used for speech recognition of nonspecific person to achieve human-machine interaction, mechanical moving parts are used to make corresponding mechanical responses to the information processed by data collection device.it is connected with data acquisition device by a means of one-way connection. There is a one-way connection between sensor device and data collection device, two-way connection between data acquisition device and voice processing module. The data collection device is one-way connection with mechanical movement parts. The intelligent processing system can judge whether it needs to interact with the customer, realize the man-machine interaction instead of the current rigid frame model.
Dynamic Optical Networks for Future Internet Environments
NASA Astrophysics Data System (ADS)
Matera, Francesco
2014-05-01
This article reports an overview on the evolution of the optical network scenario taking into account the exponential growth of connected devices, big data, and cloud computing that is driving a concrete transformation impacting the information and communication technology world. This hyper-connected scenario is deeply affecting relationships between individuals, enterprises, citizens, and public administrations, fostering innovative use cases in practically any environment and market, and introducing new opportunities and new challenges. The successful realization of this hyper-connected scenario depends on different elements of the ecosystem. In particular, it builds on connectivity and functionalities allowed by converged next-generation networks and their capacity to support and integrate with the Internet of Things, machine-to-machine, and cloud computing. This article aims at providing some hints of this scenario to contribute to analyze impacts on optical system and network issues and requirements. In particular, the role of the software-defined network is investigated by taking into account all scenarios regarding data centers, cloud computing, and machine-to-machine and trying to illustrate all the advantages that could be introduced by advanced optical communications.
NASA Astrophysics Data System (ADS)
Nelson, Kevin; Corbin, George; Blowers, Misty
2014-05-01
Machine learning is continuing to gain popularity due to its ability to solve problems that are difficult to model using conventional computer programming logic. Much of the current and past work has focused on algorithm development, data processing, and optimization. Lately, a subset of research has emerged which explores issues related to security. This research is gaining traction as systems employing these methods are being applied to both secure and adversarial environments. One of machine learning's biggest benefits, its data-driven versus logic-driven approach, is also a weakness if the data on which the models rely are corrupted. Adversaries could maliciously influence systems which address drift and data distribution changes using re-training and online learning. Our work is focused on exploring the resilience of various machine learning algorithms to these data-driven attacks. In this paper, we present our initial findings using Monte Carlo simulations, and statistical analysis, to explore the maximal achievable shift to a classification model, as well as the required amount of control over the data.
Airlift Operation Modeling Using Discrete Event Simulation (DES)
2009-12-01
Java ......................................................................................................20 2. Simkit...JRE Java Runtime Environment JVM Java Virtual Machine lbs Pounds LAM Load Allocation Mode LRM Landing Spot Reassignment Mode LEGO Listener Event...SOFTWARE DEVELOPMENT ENVIRONMENT The following are the software tools and development environment used for constructing the models. 1. Java Java
Ahmadzadeh, Arman; Arjmandi, Hamidreza; Burkovski, Andreas; Schober, Robert
2016-10-01
This paper studies the problem of receiver modeling in molecular communication systems. We consider the diffusive molecular communication channel between a transmitter nano-machine and a receiver nano-machine in a fluid environment. The information molecules released by the transmitter nano-machine into the environment can degrade in the channel via a first-order degradation reaction and those that reach the receiver nano-machine can participate in a reversible bimolecular reaction with receiver receptor proteins. Thereby, we distinguish between two scenarios. In the first scenario, we assume that the entire surface of the receiver is covered by receptor molecules. We derive a closed-form analytical expression for the expected received signal at the receiver, i.e., the expected number of activated receptors on the surface of the receiver. Then, in the second scenario, we consider the case where the number of receptor molecules is finite and the uniformly distributed receptor molecules cover the receiver surface only partially. We show that the expected received signal for this scenario can be accurately approximated by the expected received signal for the first scenario after appropriately modifying the forward reaction rate constant. The accuracy of the derived analytical results is verified by Brownian motion particle-based simulations of the considered environment, where we also show the impact of the effect of receptor occupancy on the derived analytical results.
Adaptive machine and its thermodynamic costs
NASA Astrophysics Data System (ADS)
Allahverdyan, Armen E.; Wang, Q. A.
2013-03-01
We study the minimal thermodynamically consistent model for an adaptive machine that transfers particles from a higher chemical potential reservoir to a lower one. This model describes essentials of the inhomogeneous catalysis. It is supposed to function with the maximal current under uncertain chemical potentials: if they change, the machine tunes its own structure fitting it to the maximal current under new conditions. This adaptation is possible under two limitations: (i) The degree of freedom that controls the machine's structure has to have a stored energy (described via a negative temperature). The origin of this result is traced back to the Le Chatelier principle. (ii) The machine has to malfunction at a constant environment due to structural fluctuations, whose relative magnitude is controlled solely by the stored energy. We argue that several features of the adaptive machine are similar to those of living organisms (energy storage, aging).
Using Phun to Study ``Perpetual Motion'' Machines
NASA Astrophysics Data System (ADS)
Koreš, Jaroslav
2012-05-01
The concept of "perpetual motion" has a long history. The Indian astronomer and mathematician Bhaskara II (12th century) was the first person to describe a perpetual motion (PM) machine. An example of a 13th- century PM machine is shown in Fig. 1. Although the law of conservation of energy clearly implies the impossibility of PM construction, over the centuries numerous proposals for PM have been made, involving ever more elements of modern science in their construction. It is possible to test a variety of PM machines in the classroom using a program called Phun2 or its commercial version Algodoo.3 The programs are designed to simulate physical processes and we can easily simulate mechanical machines using them. They provide an intuitive graphical environment controlled with a mouse; a programming language is not needed. This paper describes simulations of four different (supposed) PM machines.4
That Elusive, Eclectic Thing Called Thermal Environment: What a Board Should Know About It
ERIC Educational Resources Information Center
Schutte, Frederick
1970-01-01
Discussion of proper thermal environment for protection of sophisticated educational equipment such as computer and data-processing machines, magnetic tapes, closed-circuit television and video tape communications systems.
Human Machine Interfaces for Teleoperators and Virtual Environments Conference
NASA Technical Reports Server (NTRS)
1990-01-01
In a teleoperator system the human operator senses, moves within, and operates upon a remote or hazardous environment by means of a slave mechanism (a mechanism often referred to as a teleoperator). In a virtual environment system the interactive human machine interface is retained but the slave mechanism and its environment are replaced by a computer simulation. Video is replaced by computer graphics. The auditory and force sensations imparted to the human operator are similarly computer generated. In contrast to a teleoperator system, where the purpose is to extend the operator's sensorimotor system in a manner that facilitates exploration and manipulation of the physical environment, in a virtual environment system, the purpose is to train, inform, alter, or study the human operator to modify the state of the computer and the information environment. A major application in which the human operator is the target is that of flight simulation. Although flight simulators have been around for more than a decade, they had little impact outside aviation presumably because the application was so specialized and so expensive.
Biomimetics in Intelligent Sensor and Actuator Automation Systems
NASA Astrophysics Data System (ADS)
Bruckner, Dietmar; Dietrich, Dietmar; Zucker, Gerhard; Müller, Brit
Intelligent machines are really an old mankind's dream. With increasing technological development, the requirements for intelligent devices also increased. However, up to know, artificial intelligence (AI) lacks solutions to the demands of truly intelligent machines that have no problems to integrate themselves into daily human environments. Current hardware with a processing power of billions of operations per second (but without any model of human-like intelligence) could not substantially contribute to the intelligence of machines when compared with that of the early AI times. There are great results, of course. Machines are able to find the shortest path between far apart cities on the map; algorithms let you find information described only by few key words. But no machine is able to get us a cup of coffee from the kitchen yet.
1990-04-23
developed Ada Real - Time Operating System (ARTOS) for bare machine environments(Target), ACW 1.1I0. " ; - -M.UIECTTERMS Ada programming language, Ada...configuration) Operating System: CSC developed Ada Real - Time Operating System (ARTOS) for bare machine environments Memory Size: 4MB 2.2...Test Method Testing of the MC Ado V1.2.beta/ Concurrent Computer Corporation compiler and the CSC developed Ada Real - Time Operating System (ARTOS) for
A visual programming environment for the Navier-Stokes computer
NASA Technical Reports Server (NTRS)
Tomboulian, Sherryl; Crockett, Thomas W.; Middleton, David
1988-01-01
The Navier-Stokes computer is a high-performance, reconfigurable, pipelined machine designed to solve large computational fluid dynamics problems. Due to the complexity of the architecture, development of effective, high-level language compilers for the system appears to be a very difficult task. Consequently, a visual programming methodology has been developed which allows users to program the system at an architectural level by constructing diagrams of the pipeline configuration. These schematic program representations can then be checked for validity and automatically translated into machine code. The visual environment is illustrated by using a prototype graphical editor to program an example problem.
Proceedings of Annual Acquisition Research Symposium (7th), Hershey, Pennsylvania, 31 May-2 Jun 1978
1978-06-01
strongly, with DCS/Plans our efforts going during difficult periods, and Operation leadership and heavy MAJCOM but mission area planning and analysis is...implementing DOD required with heavy participation by AFSC. Directives 5000.1 and 5000.2 require new pro- Zero-Base Budgeting is the third part of the...Mission Area Analysis portion, it it -omposed of three logical steps. The fir-t .?p de - velops viable alternatives for tae -.. R&D programs. The second
1982-02-28
in March and potted in April. Seed sowing will ta..-e place in mid-May. The species sown will include a grass. wheat, lettuce and radish and C... effects varied. Soe started negativeLy, and became positive; others remained negative ( radish ), and others were positive aLl the time (wheat). ALL...agronomic plants selected were radish (Webb’s French Break- fast), lettuce (Paris White), wheat (spring), red fescue (Merlin) and ryegrass (S24). Each
Application of Pyrometry and IR-Thermography to High Surface Temperature Measurements
2000-04-01
infrared spectra. Pneumatic thermal detectors use the effect of pres- sure change in a gas chamber due to radiation The second group of quantum detectors ...application of photo conductive detectors is re- a good signal to noise ratio. Each detector has a stricted by the recombination noise due to the elec...tricity. The signal power equal to the noise power of the detector is called the noise equivalent power AE tAE (NEP). It strongly depends on the
A Retail Level Inventory Model for Naval Aviation Repairable Items.
1983-03-01
the sup porn bass for than purocss. Th e Zral-furcnicning Irit tray -then be disposed f or :epaired, a s appropr~a-s. As t:Echnology has advanced...shortcomings and work towards improvement. Jus. ’uch an effcrt has teen underway for the last five years. In 1974, the then Deputy Secretary of Defz.nse, W...actually teen adde:d to any ac-civity’S A VCAL, in 1 czly ths attriticn locrtion additives have bsen apprcveda r. 7 funded. Significantly, however, tae
JPRS Report East Asia Korea: KULLOJA No 4, April 1987.
1988-05-20
Yong -nam] [Text] Ever since he embarked upon the road of revolu- tion in his youth, the great leader Comrade Kim Il-song has constantly dedicated...Comrade Kim Il-song 41090003J Pyongyang KVLLOJA in Korean No 4, Apr 87 pp 81-88 [Article by Kye Ung -tae] [Text] As they mark the respected and...Workers Party published in Pyongyang.] The Great Leader Comrade Kim Il-song Is the Pioneer and Helmsman of the Chuche Cause 1 The Respected and Beloved
2003-01-01
dubbed UIMA . At the heart of UIMA are powerful search capabilities and a data-driven framework for the development, composition and distributed...example, to Processing Resources in the GATE archi- tecture (Cunningham et al., 2000). In UIMA , a TAE is a recursive structure which may be composed of sub...closer look at the analysis engine framework . UIMA specifies an interface for an analysis engine; roughly speaking it is “CAS in” and “CAS out
1987-12-01
Ffld. I-r &I6a ac rXpE~cjAi.Ly Pf~cgEt CiefkBIE bWb&S P-e1* I(j01Wjt SlAUEi. £jtFrc/gPAEA TAE -e.. &~C P.coy MSfi/.Cr ST~ftvh1 C0R* lID~ lA RuDf AS*fb...severe property and economia losses and a potential for environmental Impacts which could be substantially worse than the temporary Impaot to the
Characteristics for electrochemical machining with nanoscale voltage pulses.
Lee, E S; Back, S Y; Lee, J T
2009-06-01
Electrochemical machining has traditionally been used in highly specialized fields, such as those of the aerospace and defense industries. It is now increasingly being applied in other industries, where parts with difficult-to-cut material, complex geometry and tribology, and devices of nanoscale and microscale are required. Electric characteristic plays a principal function role in and chemical characteristic plays an assistant function role in electrochemical machining. Therefore, essential parameters in electrochemical machining can be described current density, machining time, inter-electrode gap size, electrolyte, electrode shape etc. Electrochemical machining provides an economical and effective method for machining high strength, high tension and heat-resistant materials into complex shapes such as turbine blades of titanium and aluminum alloys. The application of nanoscale voltage pulses between a tool electrode and a workpiece in an electrochemical environment allows the three-dimensional machining of conducting materials with sub-micrometer precision. In this study, micro probe are developed by electrochemical etching and micro holes are manufactured using these micro probe as tool electrodes. Micro holes and microgroove can be accurately achieved by using nanoscale voltages pulses.
Clinical quality needs complex adaptive systems and machine learning.
Marsland, Stephen; Buchan, Iain
2004-01-01
The vast increase in clinical data has the potential to bring about large improvements in clinical quality and other aspects of healthcare delivery. However, such benefits do not come without cost. The analysis of such large datasets, particularly where the data may have to be merged from several sources and may be noisy and incomplete, is a challenging task. Furthermore, the introduction of clinical changes is a cyclical task, meaning that the processes under examination operate in an environment that is not static. We suggest that traditional methods of analysis are unsuitable for the task, and identify complexity theory and machine learning as areas that have the potential to facilitate the examination of clinical quality. By its nature the field of complex adaptive systems deals with environments that change because of the interactions that have occurred in the past. We draw parallels between health informatics and bioinformatics, which has already started to successfully use machine learning methods.
Integration of passive driver-assistance systems with on-board vehicle systems
NASA Astrophysics Data System (ADS)
Savchenko, V. V.; Poddubko, S. N.
2018-02-01
Implementation in OIAS such functions as driver’s state monitoring and high-precision calculation of the current navigation coordinates of the vehicle, modularity of the OIAS construction and the possible increase in the functionality through integration with other onboard systems has a promising development future. The development of intelligent transport systems and their components allows setting and solving fundamentally new tasks for the safety of human-to-machine transport systems, and the automatic analysis of heterogeneous information flows provides a synergistic effect. The analysis of cross-modal information exchange in human-machine transport systems, from uniform methodological points of view, will allow us, with an accuracy acceptable for solving applied problems, to form in real time an integrated assessment of the state of the basic components of the human-to-machine system and the dynamics in changing situation-centered environment, including the external environment, in their interrelations.
Operation of micro and molecular machines: a new concept with its origins in interface science.
Ariga, Katsuhiko; Ishihara, Shinsuke; Izawa, Hironori; Xia, Hong; Hill, Jonathan P
2011-03-21
A landmark accomplishment of nanotechnology would be successful fabrication of ultrasmall machines that can work like tweezers, motors, or even computing devices. Now we must consider how operation of micro- and molecular machines might be implemented for a wide range of applications. If these machines function only under limited conditions and/or require specialized apparatus then they are useless for practical applications. Therefore, it is important to carefully consider the access of functionality of the molecular or nanoscale systems by conventional stimuli at the macroscopic level. In this perspective, we will outline the position of micro- and molecular machines in current science and technology. Most of these machines are operated by light irradiation, application of electrical or magnetic fields, chemical reactions, and thermal fluctuations, which cannot always be applied in remote machine operation. We also propose strategies for molecular machine operation using the most conventional of stimuli, that of macroscopic mechanical force, achieved through mechanical operation of molecular machines located at an air-water interface. The crucial roles of the characteristics of an interfacial environment, i.e. connection between macroscopic dimension and nanoscopic function, and contact of media with different dielectric natures, are also described.
Neumark-Sztainer, Dianne; French, Simone A; Hannan, Peter J; Story, Mary; Fulkerson, Jayne A
2005-10-06
This study examined associations between high school students' lunch patterns and vending machine purchases and the school food environment and policies. A randomly selected sample of 1088 high school students from 20 schools completed surveys about their lunch practices and vending machine purchases. School food policies were assessed by principal and food director surveys. The number of vending machines and their hours of operation were assessed by trained research staff. Students at schools with open campus policies during lunchtime were significantly more likely to eat lunch at a fast food restaurant than students at schools with closed campus policies (0.7 days/week vs. 0.2 days/week, p < .001). Student snack food purchases at school were significantly associated with the number of snack machines at schools (p < .001) and policies about the types of food that can be sold. In schools with policies, students reported making snack food purchases an average of 0.5 +/- 1.1 days/week as compared to an average of 0.9 +/- 1.3 days/week in schools without policies (p < .001). In schools in which soft drink machines were turned off during lunch time, students purchased soft drinks from vending machines 1.4 +/- 1.6 days/week as compared to 1.9 +/- 1.8 days/week in schools in which soft drink machines were turned on during lunch (p = .040). School food policies that decrease access to foods high in fats and sugars are associated with less frequent purchase of these items in school among high school students. Schools should examine their food-related policies and decrease access to foods that are low in nutrients and high in fats and sugars.
Neumark-Sztainer, Dianne; French, Simone A; Hannan, Peter J; Story, Mary; Fulkerson, Jayne A
2005-01-01
Objectives This study examined associations between high school students' lunch patterns and vending machine purchases and the school food environment and policies. Methods A randomly selected sample of 1088 high school students from 20 schools completed surveys about their lunch practices and vending machine purchases. School food policies were assessed by principal and food director surveys. The number of vending machines and their hours of operation were assessed by trained research staff. Results Students at schools with open campus policies during lunchtime were significantly more likely to eat lunch at a fast food restaurant than students at schools with closed campus policies (0.7 days/week vs. 0.2 days/week, p < .001). Student snack food purchases at school were significantly associated with the number of snack machines at schools (p < .001) and policies about the types of food that can be sold. In schools with policies, students reported making snack food purchases an average of 0.5 ± 1.1 days/week as compared to an average of 0.9 ± 1.3 days/week in schools without policies (p < .001). In schools in which soft drink machines were turned off during lunch time, students purchased soft drinks from vending machines 1.4 ± 1.6 days/week as compared to 1.9 ± 1.8 days/week in schools in which soft drink machines were turned on during lunch (p = .040). Conclusion School food policies that decrease access to foods high in fats and sugars are associated with less frequent purchase of these items in school among high school students. Schools should examine their food-related policies and decrease access to foods that are low in nutrients and high in fats and sugars. PMID:16209716
The phaco machine: analysing new technology.
Fishkind, William J
2013-01-01
The phaco machine is frequently overlooked as the crucial surgical instrument it is. Understanding how to set parameters is initiated by understanding fundamental concepts of machine function. This study analyses the critical concepts of partial occlusion phaco, occlusion phaco and pump technology. In addition, phaco energy categories as well as variations of phaco energy production are explored. Contemporary power modulations and pump controls allow for the enhancement of partial occlusion phacoemulsification. These significant changes in the anterior chamber dynamics produce a balanced environment for phaco; less complications; and improved patient outcomes.
Advanced Resistive Exercise Device
NASA Technical Reports Server (NTRS)
Raboin, Jasen; Niebuhr, Jason; Cruz, Santana; Lamoreaux, chris
2007-01-01
The advanced resistive exercise device (ARED), now at the prototype stage of development, is a versatile machine that can be used to perform different customized exercises for which, heretofore, it has been necessary to use different machines. Conceived as a means of helping astronauts and others to maintain muscle and bone strength and endurance in low-gravity environments, the ARED could also prove advantageous in terrestrial settings (e.g., health clubs and military training facilities) in which many users are exercising simultaneously and there is heavy demand for use of exercise machines.
Automated fiber pigtailing machine
Strand, O.T.; Lowry, M.E.
1999-01-05
The Automated Fiber Pigtailing Machine (AFPM) aligns and attaches optical fibers to optoelectronic (OE) devices such as laser diodes, photodiodes, and waveguide devices without operator intervention. The so-called pigtailing process is completed with sub-micron accuracies in less than 3 minutes. The AFPM operates unattended for one hour, is modular in design and is compatible with a mass production manufacturing environment. This machine can be used to build components which are used in military aircraft navigation systems, computer systems, communications systems and in the construction of diagnostics and experimental systems. 26 figs.
Modeling stochastic kinetics of molecular machines at multiple levels: from molecules to modules.
Chowdhury, Debashish
2013-06-04
A molecular machine is either a single macromolecule or a macromolecular complex. In spite of the striking superficial similarities between these natural nanomachines and their man-made macroscopic counterparts, there are crucial differences. Molecular machines in a living cell operate stochastically in an isothermal environment far from thermodynamic equilibrium. In this mini-review we present a catalog of the molecular machines and an inventory of the essential toolbox for theoretically modeling these machines. The tool kits include 1), nonequilibrium statistical-physics techniques for modeling machines and machine-driven processes; and 2), statistical-inference methods for reverse engineering a functional machine from the empirical data. The cell is often likened to a microfactory in which the machineries are organized in modular fashion; each module consists of strongly coupled multiple machines, but different modules interact weakly with each other. This microfactory has its own automated supply chain and delivery system. Buoyed by the success achieved in modeling individual molecular machines, we advocate integration of these models in the near future to develop models of functional modules. A system-level description of the cell from the perspective of molecular machinery (the mechanome) is likely to emerge from further integrations that we envisage here. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Large-Scale Distributed Computational Fluid Dynamics on the Information Power Grid Using Globus
NASA Technical Reports Server (NTRS)
Barnard, Stephen; Biswas, Rupak; Saini, Subhash; VanderWijngaart, Robertus; Yarrow, Maurice; Zechtzer, Lou; Foster, Ian; Larsson, Olle
1999-01-01
This paper describes an experiment in which a large-scale scientific application development for tightly-coupled parallel machines is adapted to the distributed execution environment of the Information Power Grid (IPG). A brief overview of the IPG and a description of the computational fluid dynamics (CFD) algorithm are given. The Globus metacomputing toolkit is used as the enabling device for the geographically-distributed computation. Modifications related to latency hiding and Load balancing were required for an efficient implementation of the CFD application in the IPG environment. Performance results on a pair of SGI Origin 2000 machines indicate that real scientific applications can be effectively implemented on the IPG; however, a significant amount of continued effort is required to make such an environment useful and accessible to scientists and engineers.
The AE-8 trapped electron model environment
NASA Technical Reports Server (NTRS)
Vette, James I.
1991-01-01
The machine sensible version of the AE-8 electron model environment was completed in December 1983. It has been sent to users on the model environment distribution list and is made available to new users by the National Space Science Data Center (NSSDC). AE-8 is the last in a series of terrestrial trapped radiation models that includes eight proton and eight electron versions. With the exception of AE-8, all these models were documented in formal reports as well as being available in a machine sensible form. The purpose of this report is to complete the documentation, finally, for AE-8 so that users can understand its construction and see the comparison of the model with the new data used, as well as with the AE-4 model.
DOT National Transportation Integrated Search
2009-03-20
International Electronic Machines Corporation (IEM) has developed and is now marketing a state-of-the-art Wheel Inspection System Environment (WISE). WISE provides wheel profile and dimensional measurements, i.e. rim thickness, flange height, flange ...
Chiappini, L; Delery, L; Leoz, E; Brouard, B; Fagault, Y
2009-06-01
Used as a solvent in the dry-cleaning industry, tetrachloroethylene (C(2)Cl(4)) can be a pollutant of residential indoor air, which can cause long-term harmful exposures because of its neurotoxicity and probable carcinogenicity. In France, dry-cleaning facilities are integrated in urban environments (shopping malls, residential buildings) and can contribute to C(2)Cl(4) exposure for customers and residents. This exploratory work presents the results from five studies carried out in one shopping mall and four residential buildings housing a dry-cleaning facility. These studies involved dry-cleaning machines fitted with a Carbon Adsorber and unfitted, with or without Air Exhaust System. Samples were collected in the cleaning facilities and in the apartments located above with passive samplers allowing measurement of time-integrated concentrations on a 7 days sampling period. It has obviously shown the degradation of indoor air quality in these environments and underlined the contributing role of the machine technology and ventilation system on the amount of released C(2)Cl(4) in the indoor air. To temper these results, it must be pointed out that some parameters (building insulation, amount of solvent used...) which would influence C(2)Cl(4) fugitive release have not been quantified and should be looked at in further studies. In France, dry-cleaning facilities are frequently integrated in urban environments (large shopping malls or residential buildings) and can significantly contribute to tetrachloroethylene (C(2)Cl(4)) population exposure. The amount of fugitive releases in these environments depends on several parameters such as the dry-cleaning machine technology (fitted or unfitted with a carbon adsorber) and the ventilation (air exhaust system). To reduce C(2)Cl(4) exposure in residential buildings and other indoor environments with on-site dry cleaners, carbon adsorber unequipped machine should be replaced by newer technology and dry cleaners should be equipped with mechanical air exhaust systems.
NASA Astrophysics Data System (ADS)
Bondarenko, J. A.; Fedorenko, M. A.; Pogonin, A. A.
2018-03-01
Large parts can be treated without disassembling machines using “Extra”, having technological and design challenges, which differ from the challenges in the processing of these components on the stationary machine. Extension machines are used to restore large parts up to the condition allowing one to use them in a production environment. To achieve the desired accuracy and surface roughness parameters, the surface after rotary grinding becomes recoverable, which greatly increases complexity. In order to improve production efficiency and productivity of the process, the qualitative rotary processing of the machined surface is applied. The rotary cutting process includes a continuous change of the cutting edge surfaces. The kinematic parameters of a rotary cutting define its main features and patterns, the cutting operation of the rotary cutting instrument.
Association Rule-based Predictive Model for Machine Failure in Industrial Internet of Things
NASA Astrophysics Data System (ADS)
Kwon, Jung-Hyok; Lee, Sol-Bee; Park, Jaehoon; Kim, Eui-Jik
2017-09-01
This paper proposes an association rule-based predictive model for machine failure in industrial Internet of things (IIoT), which can accurately predict the machine failure in real manufacturing environment by investigating the relationship between the cause and type of machine failure. To develop the predictive model, we consider three major steps: 1) binarization, 2) rule creation, 3) visualization. The binarization step translates item values in a dataset into one or zero, then the rule creation step creates association rules as IF-THEN structures using the Lattice model and Apriori algorithm. Finally, the created rules are visualized in various ways for users’ understanding. An experimental implementation was conducted using R Studio version 3.3.2. The results show that the proposed predictive model realistically predicts machine failure based on association rules.
Health Promotion and Healthier Products Increase Vending Purchases: A Randomized Factorial Trial.
Hua, Sophia V; Kimmel, Lisa; Van Emmenes, Michael; Taherian, Rafi; Remer, Geraldine; Millman, Adam; Ickovics, Jeannette R
2017-07-01
The current food environment has a high prevalence of nutrient-sparse foods and beverages, most starkly seen in vending machine offerings. There are currently few studies that explore different interventions that might lead to healthier vending machine purchases. To examine how healthier product availability, price reductions, and/or promotional signs affect sales and revenue of snack and beverage vending machines. A 2×2×2 factorial randomized controlled trial was conducted. Students, staff, and employees on a university campus. All co-located snack and beverage vending machines (n=56, 28 snack and 28 beverage) were randomized into one of eight conditions: availability of healthier products and/or 25% price reduction for healthier items and/or promotional signs on machines. Aggregate sales and revenue data for the 5-month study period (February to June 2015) were compared with data from the same months 1 year prior. Analyses were conducted July 2015. The change in units sold and revenue between February through June 2014 and 2015. Linear regression models (main effects and interaction effects) and t test analyses were performed. The interaction between healthier product guidelines and promotional signs in snack vending machines documented increased revenue (P<0.05). Beverage machines randomized to meet healthier product guidelines documented increased units sold (P<0.05) with no revenue change. Price reductions alone had no effect, nor were there any effects for the three-way interaction of the factors. Examining top-selling products for all vending machines combined, pre- to postintervention, we found an overall shift to healthier purchasing. When healthier vending snacks are available, promotional signs are also important to ensure consumers purchase those items in greater amounts. Mitigating potential loss in profits is essential for sustainability of a healthier food environment. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
A pilot study to characterize fine particles in the environment of an automotive machining facility.
Sioutas, C
1999-04-01
The main goal of this study was to characterize fine particles (e.g., smaller than about 3 microns) in an automotive machining environment. The Toledo Machining Plant of Chrysler Corporation was selected for this purpose. The effect of local mechanical processes as aerosol sources was a major part of this investigation. To determine the size-dependent mass concentration of particles in the plant, the Micro-Orifice Uniform Deposit Impactor (MOUDI Model 100, MSP Corp., Minneapolis, Minnesota) was used. The MOUDI was placed at central locations in departments with sources inside the plant, so that the obtained information on the size distribution realistically represents the aerosol to which plant workers are exposed. Sampling was conducted over a 4-day period, and during three periods per day, each matching the work shifts. A special effort was made to place the MOUDI at a central location of a department with relatively homogeneous particle sources. The selected sampling sites included welding, grinding, steel machining, and heat treating processes. The average 24-hour mass concentrations of particles smaller than 3.2 microns in aerodynamic diameter were 167.8, 103.9, 201.7, and 112.7 micrograms/m3 for welding, grinding, mild steel, and heat treating processes, respectively. Finally, the mass median diameters of welding, heat treatment, machining, and grinding operations were approximately 0.5, 0.5, 0.6, and 0.8 micron, respectively.
Nonoperative Management of a Large Extrapleural Hematoma after Blunt Chest Trauma.
Gorospe, Luis; Fernández-Méndez, María Ángeles; Ayala-Carbonero, Ana; Cabañero-Sánchez, Alberto; Muñoz-Molina, Gemma María
2016-08-01
An extrapleural hematoma (EH) is an uncommon and potentially life-threatening condition defined as the accumulation of blood in the extrapleural space between the parietal pleura and the endothoracic fascia. EH usually occurs after blunt thoracic trauma causing fractures of the sternum and ribs, which can tear the intercostal or internal mammary vessels. Typical radiological findings of EH are a biconvex opacity on the involved hemithorax and the so-called displaced "extrapleural fat sign." We present a case of a 36-year-old man with an isolated scapular fracture after a high-energy blunt chest trauma complicated with a large contralateral EH that was successfully managed nonoperatively with transcatheter arterial embolization (TAE) and image-guided drainage with a pig-tail catheter. To the best of our knowledge there is only one previous report describing a large EH after blunt thoracic trauma without rib fractures. Only two previous cases of large EHs have been treated initially with TAE, but both patients ultimately required open surgery. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Patients with EH can present with respiratory distress and hypotension, so early identification is important to facilitate proper treatment. EH has characteristic radiological findings, and contrast-enhanced computed tomography is not only the best imaging tool for confirming an EH, but also the best technique for detecting the source of the bleeding and other serious thoracic complications that may not be evident on chest x-ray studies. Copyright © 2016 Elsevier Inc. All rights reserved.
The attenuation of strike acceleration with the use of safety equipment in tae kwon do.
Gupta, Sanjey
2011-12-01
THE OBJECTIVES OF THIS STUDY INCLUDE: (1) Determination of the attenuation of strike acceleration that Tae Kwon Do sparring safety pads provide from kicks from Olympic style TKD fighters, (2) The sex and weight differentiation in acceleration achieved within the thorax model with the roundhouse kicks. This prospective, observational study utilized 15 Olympic style fighters from an "elite" team kicking a water core heavy bag thorax model with roundhouse kicks. The model was fitted with a tri-axial accelerometer (GCDC, model X250-2) to measure g acceleration from strikes to the bag. The bag was kicked in three, 10 kick phases by all subjects: kicks without padding; kicks with hogu on heavy bag, and kicks with hogu and instep guards on feet. The g acceleration readings were recorded in all phases. Kolmogorov-Smirnov failed for all variables. There were 8 female subjects: median age 14 years, median weight 53.4 kg and 7 male subjects: median age 17 years, median weight 70.45 kg. The ANOVA on ranks of the acceleration from kicks against the bag achieved significance, P=0.001. Spearman rank order correlation between the weights of players and acceleration of strike against the hogu without and with insteps pads was significant, P=0.035/r=0.54 and P=0.018/r=0.59, respectively. Heavier and male subjects tend to produce more force in strikes. Protective chest guard reduces acceleration to the thorax model, but the utility of instep guards is questionable.
Salis, Andrea; Porcu, Elena P; Gavini, Elisabetta; Fois, Giulia R; Icaro Cornaglia, Antonia; Rassu, Giovanna; Diana, Marco; Maestri, Marcello; Giunchedi, Paolo; Nikolakakis, Ioannis
2017-04-01
In situ forming biodegradable poly(ε-caprolactone) (PCL) microspheres (PCL-ISM) system was developed as a novel embolic agent for transarterial embolization (TAE) therapy of hepatocellular carcinoma (HCC). Ibuprofen sodium (Ibu-Na) was loaded on this platform to evaluate its potential for the treatment of post embolization syndrome. The influence of formulation parameters on the size/shape, encapsulation efficiency and drug release was investigated using mixture experimental design. Regression models were derived and used to optimize the formulation for particle size, encapsulation efficiency and drug release profile for TAE therapy. An ex vivo model using isolated rat livers was established to assess the in situ formation of microspheres. All PCL-ISM components affected the studied properties and fitting indices of the regression models were high (Radj 2 = 0.810 for size, 0.964 encapsulation efficiency, and 0.993 or 0.971 for drug release at 30 min or 48 h). The optimized composition was: PCL = 4%, NMP = 43.1%, oil = 48.9%, surfactant = 2% and drug = 2%. Ex vivo studies revealed that PCL-ISM was able to form microspheres in the hepatic arterial bed. PCL-ISM system provides a novel tool for the treatment of HCC and post-embolization syndrome. It is capable of forming microspheres with desirable size and Ibu-Na release profile after injection into blood vessels.
Mimura, Kensuke; Matsumoto, Hidetaka; Morimoto, Masahiro; Akiyama, Hideo
2018-01-01
To evaluate the development of neovascular age-related macular degeneration (nAMD) in the fellow eye in patients with unilateral nAMD treated by a treat-and-extend (TAE) regimen with intravitreal aflibercept injections. We retrospectively studied 104 patients with treatment-naïve unilateral nAMD. We assessed best-corrected visual acuity (BCVA) and exudative changes in the treated eyes and development of nAMD in the fellow eye for 2 years. The subjects included 46 patients with typical AMD (tAMD), 44 with polypoidal choroidal vasculopathy (PCV), and 14 with retinal angiomatous proliferation (RAP). BCVA was significantly improved after the loading phase in all subtypes. Forty-six patients (44.2%) had no recurrence within 2 years after the loading phase, including 12 (26.1%) with tAMD, 23 (52.2%) with PCV, and 11 (78.6%) with RAP (p < 0.01). Eleven patients (10.6%) developed nAMD in the fellow eye within 2 years, including 4 (8.7%) with tAMD, 0 (0%) with PCV, and 7 (50.0%) with RAP (p < 0.001). Patients with RAP had significantly more frequent development of nAMD in the fellow eye compared to other subtypes, while they showed significantly less recurrence during the TAE regimen with intravitreal aflibercept injections. Development of nAMD in the fellow eye should be monitored in RAP when the injection interval is extended. © 2017 S. Karger AG, Basel.
Technology: The Culture of Machine Living. Program in American History and Civilization.
ERIC Educational Resources Information Center
Tufts Univ., Medford, MA. Lincoln Filene Center for Citizenship and Public Affairs.
The readings in this narrative unit are concerned with the machine's role today and its future use in shaping man's environment. The general teaching objectives are to enable the student: 1) to adapt to a society directed toward total living, rather than one in which he earns a living; 2) to understand that uncontrolled technological advance may…
Virtual Machine Language Controls Remote Devices
NASA Technical Reports Server (NTRS)
2014-01-01
Kennedy Space Center worked with Blue Sun Enterprises, based in Boulder, Colorado, to enhance the company's virtual machine language (VML) to control the instruments on the Regolith and Environment Science and Oxygen and Lunar Volatiles Extraction mission. Now the NASA-improved VML is available for crewed and uncrewed spacecraft, and has potential applications on remote systems such as weather balloons, unmanned aerial vehicles, and submarines.
A Flexible Approach to Quantifying Various Dimensions of Environmental Complexity
2004-08-01
dissertation, Cambridge University, Cambridge, England, 1989. [15] C. J. C. H. Watkins and P. Dayan, “Q-learning,” Machine Learning , vol. 8, pp. 279–292, 1992...16] I. Szita, B. Takács, and A. Lörincz, “²-MDPs: Learning in varying environments,” Journal of Machine Learning Research, vol. 3, pp. 145–174, 2002
Code of Federal Regulations, 2010 CFR
2010-07-01
... MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank... used to pass the inspections under § 157.140: (1) Pressure and flow of the crude oil pumped to the COW machines. (2) Revolutions, number of cycles, and length of cycles of each COW machine. (3) Pressure and...
Color machine vision in industrial process control: case limestone mine
NASA Astrophysics Data System (ADS)
Paernaenen, Pekka H. T.; Lemstrom, Guy F.; Koskinen, Seppo
1994-11-01
An optical sorter technology has been developed to improve profitability of a mine by using color line scan machine vision technology. The new technology adapted longers the expected life time of the limestone mine and improves its efficiency. Also the project has proved that color line scan technology of today can successfully be applied to industrial use in harsh environments.
A Virtual Astronomical Research Machine in No Time (VARMiNT)
NASA Astrophysics Data System (ADS)
Beaver, John
2012-05-01
We present early results of using virtual machine software to help make astronomical research computing accessible to a wider range of individuals. Our Virtual Astronomical Research Machine in No Time (VARMiNT) is an Ubuntu Linux virtual machine with free, open-source software already installed and configured (and in many cases documented). The purpose of VARMiNT is to provide a ready-to-go astronomical research computing environment that can be freely shared between researchers, or between amateur and professional, teacher and student, etc., and to circumvent the often-difficult task of configuring a suitable computing environment from scratch. Thus we hope that VARMiNT will make it easier for individuals to engage in research computing even if they have no ready access to the facilities of a research institution. We describe our current version of VARMiNT and some of the ways it is being used at the University of Wisconsin - Fox Valley, a two-year teaching campus of the University of Wisconsin System, as a means to enhance student independent study research projects and to facilitate collaborations with researchers at other locations. We also outline some future plans and prospects.
Harper, Jason C.; Carson, Bryan D.; Bachand, George D.; ...
2015-07-14
Despite significant progress in development of bioanalytical devices cost, complexity, access to reagents and lack of infrastructure have prevented use of these technologies in resource-limited regions. To provide a sustainable tool in the global effort to combat infectious diseases the diagnostic device must be low cost, simple to operate and read, robust, and have sensitivity and specificity comparable to laboratory analysis. Thus, in this mini-review we describe recent work using laser machined plastic laminates to produce diagnostic devices that are capable of a wide variety of bioanalytical measurements and show great promise towards future use in low-resource environments.
NASA Astrophysics Data System (ADS)
Digney, Bruce L.
2007-04-01
Unmanned vehicle systems is an attractive technology for the military, but whose promises have remained largely undelivered. There currently exist fielded remote controlled UGVs and high altitude UAV whose benefits are based on standoff in low complexity environments with sufficiently low control reaction time requirements to allow for teleoperation. While effective within there limited operational niche such systems do not meet with the vision of future military UxV scenarios. Such scenarios envision unmanned vehicles operating effectively in complex environments and situations with high levels of independence and effective coordination with other machines and humans pursing high level, changing and sometimes conflicting goals. While these aims are clearly ambitious they do provide necessary targets and inspiration with hopes of fielding near term useful semi-autonomous unmanned systems. Autonomy involves many fields of research including machine vision, artificial intelligence, control theory, machine learning and distributed systems all of which are intertwined and have goals of creating more versatile broadly applicable algorithms. Cohort is a major Applied Research Program (ARP) led by Defence R&D Canada (DRDC) Suffield and its aim is to develop coordinated teams of unmanned vehicles (UxVs) for urban environments. This paper will discuss the critical science being addressed by DRDC developing semi-autonomous systems.
Full-motion video analysis for improved gender classification
NASA Astrophysics Data System (ADS)
Flora, Jeffrey B.; Lochtefeld, Darrell F.; Iftekharuddin, Khan M.
2014-06-01
The ability of computer systems to perform gender classification using the dynamic motion of the human subject has important applications in medicine, human factors, and human-computer interface systems. Previous works in motion analysis have used data from sensors (including gyroscopes, accelerometers, and force plates), radar signatures, and video. However, full-motion video, motion capture, range data provides a higher resolution time and spatial dataset for the analysis of dynamic motion. Works using motion capture data have been limited by small datasets in a controlled environment. In this paper, we explore machine learning techniques to a new dataset that has a larger number of subjects. Additionally, these subjects move unrestricted through a capture volume, representing a more realistic, less controlled environment. We conclude that existing linear classification methods are insufficient for the gender classification for larger dataset captured in relatively uncontrolled environment. A method based on a nonlinear support vector machine classifier is proposed to obtain gender classification for the larger dataset. In experimental testing with a dataset consisting of 98 trials (49 subjects, 2 trials per subject), classification rates using leave-one-out cross-validation are improved from 73% using linear discriminant analysis to 88% using the nonlinear support vector machine classifier.
A Cooperative Approach to Virtual Machine Based Fault Injection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Naughton III, Thomas J; Engelmann, Christian; Vallee, Geoffroy R
Resilience investigations often employ fault injection (FI) tools to study the effects of simulated errors on a target system. It is important to keep the target system under test (SUT) isolated from the controlling environment in order to maintain control of the experiement. Virtual machines (VMs) have been used to aid these investigations due to the strong isolation properties of system-level virtualization. A key challenge in fault injection tools is to gain proper insight and context about the SUT. In VM-based FI tools, this challenge of target con- text is increased due to the separation between host and guest (VM).more » We discuss an approach to VM-based FI that leverages virtual machine introspection (VMI) methods to gain insight into the target s context running within the VM. The key to this environment is the ability to provide basic information to the FI system that can be used to create a map of the target environment. We describe a proof- of-concept implementation and a demonstration of its use to introduce simulated soft errors into an iterative solver benchmark running in user-space of a guest VM.« less
LHCb experience with running jobs in virtual machines
NASA Astrophysics Data System (ADS)
McNab, A.; Stagni, F.; Luzzi, C.
2015-12-01
The LHCb experiment has been running production jobs in virtual machines since 2013 as part of its DIRAC-based infrastructure. We describe the architecture of these virtual machines and the steps taken to replicate the WLCG worker node environment expected by user and production jobs. This relies on the uCernVM system for providing root images for virtual machines. We use the CernVM-FS distributed filesystem to supply the root partition files, the LHCb software stack, and the bootstrapping scripts necessary to configure the virtual machines for us. Using this approach, we have been able to minimise the amount of contextualisation which must be provided by the virtual machine managers. We explain the process by which the virtual machine is able to receive payload jobs submitted to DIRAC by users and production managers, and how this differs from payloads executed within conventional DIRAC pilot jobs on batch queue based sites. We describe our operational experiences in running production on VM based sites managed using Vcycle/OpenStack, Vac, and HTCondor Vacuum. Finally we show how our use of these resources is monitored using Ganglia and DIRAC.
A consideration of the operation of automatic production machines.
Hoshi, Toshiro; Sugimoto, Noboru
2015-01-01
At worksites, various automatic production machines are in use to release workers from muscular labor or labor in the detrimental environment. On the other hand, a large number of industrial accidents have been caused by automatic production machines. In view of this, this paper considers the operation of automatic production machines from the viewpoint of accident prevention, and points out two types of machine operation - operation for which quick performance is required (operation that is not permitted to be delayed) - and operation for which composed performance is required (operation that is not permitted to be performed in haste). These operations are distinguished by operation buttons of suitable colors and shapes. This paper shows that these characteristics are evaluated as "asymmetric on the time-axis". Here, in order for workers to accept the risk of automatic production machines, it is preconditioned in general that harm should be sufficiently small or avoidance of harm is easy. In this connection, this paper shows the possibility of facilitating the acceptance of the risk of automatic production machines by enhancing the asymmetric on the time-axis.
Notes on a storage manager for the Clouds kernel
NASA Technical Reports Server (NTRS)
Pitts, David V.; Spafford, Eugene H.
1986-01-01
The Clouds project is research directed towards producing a reliable distributed computing system. The initial goal is to produce a kernel which provides a reliable environment with which a distributed operating system can be built. The Clouds kernal consists of a set of replicated subkernels, each of which runs on a machine in the Clouds system. Each subkernel is responsible for the management of resources on its machine; the subkernal components communicate to provide the cooperation necessary to meld the various machines into one kernel. The implementation of a kernel-level storage manager that supports reliability is documented. The storage manager is a part of each subkernel and maintains the secondary storage residing at each machine in the distributed system. In addition to providing the usual data transfer services, the storage manager ensures that data being stored survives machine and system crashes, and that the secondary storage of a failed machine is recovered (made consistent) automatically when the machine is restarted. Since the storage manager is part of the Clouds kernel, efficiency of operation is also a concern.
Detecting Abnormal Machine Characteristics in Cloud Infrastructures
NASA Technical Reports Server (NTRS)
Bhaduri, Kanishka; Das, Kamalika; Matthews, Bryan L.
2011-01-01
In the cloud computing environment resources are accessed as services rather than as a product. Monitoring this system for performance is crucial because of typical pay-peruse packages bought by the users for their jobs. With the huge number of machines currently in the cloud system, it is often extremely difficult for system administrators to keep track of all machines using distributed monitoring programs such as Ganglia1 which lacks system health assessment and summarization capabilities. To overcome this problem, we propose a technique for automated anomaly detection using machine performance data in the cloud. Our algorithm is entirely distributed and runs locally on each computing machine on the cloud in order to rank the machines in order of their anomalous behavior for given jobs. There is no need to centralize any of the performance data for the analysis and at the end of the analysis, our algorithm generates error reports, thereby allowing the system administrators to take corrective actions. Experiments performed on real data sets collected for different jobs validate the fact that our algorithm has a low overhead for tracking anomalous machines in a cloud infrastructure.
A consideration of the operation of automatic production machines
HOSHI, Toshiro; SUGIMOTO, Noboru
2015-01-01
At worksites, various automatic production machines are in use to release workers from muscular labor or labor in the detrimental environment. On the other hand, a large number of industrial accidents have been caused by automatic production machines. In view of this, this paper considers the operation of automatic production machines from the viewpoint of accident prevention, and points out two types of machine operation − operation for which quick performance is required (operation that is not permitted to be delayed) − and operation for which composed performance is required (operation that is not permitted to be performed in haste). These operations are distinguished by operation buttons of suitable colors and shapes. This paper shows that these characteristics are evaluated as “asymmetric on the time-axis”. Here, in order for workers to accept the risk of automatic production machines, it is preconditioned in general that harm should be sufficiently small or avoidance of harm is easy. In this connection, this paper shows the possibility of facilitating the acceptance of the risk of automatic production machines by enhancing the asymmetric on the time-axis. PMID:25739898
NASA Astrophysics Data System (ADS)
Zhang, F. H.; Wang, S. F.; An, C. H.; Wang, J.; Xu, Q.
2017-06-01
Large-aperture potassium dihydrogen phosphate (KDP) crystals are widely used in the laser path of inertial confinement fusion (ICF) systems. The most common method of manufacturing half-meter KDP crystals is ultra-precision fly cutting. When processing KDP crystals by ultra-precision fly cutting, the dynamic characteristics of the fly cutting machine and fluctuations in the fly cutting environment are translated into surface errors at different spatial frequency bands. These machining errors should be suppressed effectively to guarantee that KDP crystals meet the full-band machining accuracy specified in the evaluation index. In this study, the anisotropic machinability of KDP crystals and the causes of typical surface errors in ultra-precision fly cutting of the material are investigated. The structures of the fly cutting machine and existing processing parameters are optimized to improve the machined surface quality. The findings are theoretically and practically important in the development of high-energy laser systems in China.
Machine vision 1992-1996: technology program to promote research and its utilization in industry
NASA Astrophysics Data System (ADS)
Soini, Antti J.
1994-10-01
Machine vision technology has got a strong interest in Finnish research organizations, which is resulting in many innovative products to industry. Despite this end users were very skeptical towards machine vision and its robustness for harsh industrial environments. Therefore Technology Development Centre, TEKES, who funds technology related research and development projects in universities and individual companies, decided to start a national technology program, Machine Vision 1992 - 1996. Led by industry the program boosts research in machine vision technology and seeks to put the research results to work in practical industrial applications. The emphasis is in nationally important, demanding applications. The program will create new industry and business for machine vision producers and encourage the process and manufacturing industry to take advantage of this new technology. So far 60 companies and all major universities and research centers are working on our forty different projects. The key themes that we have are process control, robot vision and quality control.
Machine vision for digital microfluidics
NASA Astrophysics Data System (ADS)
Shin, Yong-Jun; Lee, Jeong-Bong
2010-01-01
Machine vision is widely used in an industrial environment today. It can perform various tasks, such as inspecting and controlling production processes, that may require humanlike intelligence. The importance of imaging technology for biological research or medical diagnosis is greater than ever. For example, fluorescent reporter imaging enables scientists to study the dynamics of gene networks with high spatial and temporal resolution. Such high-throughput imaging is increasingly demanding the use of machine vision for real-time analysis and control. Digital microfluidics is a relatively new technology with expectations of becoming a true lab-on-a-chip platform. Utilizing digital microfluidics, only small amounts of biological samples are required and the experimental procedures can be automatically controlled. There is a strong need for the development of a digital microfluidics system integrated with machine vision for innovative biological research today. In this paper, we show how machine vision can be applied to digital microfluidics by demonstrating two applications: machine vision-based measurement of the kinetics of biomolecular interactions and machine vision-based droplet motion control. It is expected that digital microfluidics-based machine vision system will add intelligence and automation to high-throughput biological imaging in the future.
NASA Astrophysics Data System (ADS)
Michaelis, A.; Nemani, R. R.; Wang, W.; Votava, P.; Hashimoto, H.
2010-12-01
Given the increasing complexity of climate modeling and analysis tools, it is often difficult and expensive to build or recreate an exact replica of the software compute environment used in past experiments. With the recent development of new technologies for hardware virtualization, an opportunity exists to create full modeling, analysis and compute environments that are “archiveable”, transferable and may be easily shared amongst a scientific community or presented to a bureaucratic body if the need arises. By encapsulating and entire modeling and analysis environment in a virtual machine image, others may quickly gain access to the fully built system used in past experiments, potentially easing the task and reducing the costs of reproducing and verify past results produced by other researchers. Moreover, these virtual machine images may be used as a pedagogical tool for others that are interested in performing an academic exercise but don't yet possess the broad expertise required. We built two virtual machine images, one with the Community Earth System Model (CESM) and one with Weather Research Forecast Model (WRF), then ran several small experiments to assess the feasibility, performance overheads costs, reusability, and transferability. We present a list of the pros and cons as well as lessoned learned from utilizing virtualization technology in the climate and earth systems modeling domain.
Operational results for the experimental DOE/NASA Mod-OA wind turbine project
NASA Astrophysics Data System (ADS)
Shaltens, R. K.; Birchenough, A. G.
The Mod-OA wind turbine project which was to gain early experience in the operation of large wind turbines in a utility environment is discussed. The Mod-OA wind turbines were a first generation design, and even though not cost effective, the operating experience and performance characteristics had a significant effect on the design and development of the second and third generation machines. The Mod-OA machines were modified as a result of the operational experience, particularly the blade development and control system strategy. The results of study to investigate the interaction of a Mod-OA wind turbine with an isolated diesel generation system are discussed. The machine configuration, its advantages and disadvantages and the machine performance and availability are discussed.
Operational results for the experimental DOE/NASA Mod-OA wind turbine project
NASA Technical Reports Server (NTRS)
Shaltens, R. K.; Birchenough, A. G.
1983-01-01
The Mod-OA wind turbine project which was to gain early experience in the operation of large wind turbines in a utility environment is discussed. The Mod-OA wind turbines were a first generation design, and even though not cost effective, the operating experience and performance characteristics had a significant effect on the design and development of the second and third generation machines. The Mod-OA machines were modified as a result of the operational experience, particularly the blade development and control system strategy. The results of study to investigate the interaction of a Mod-OA wind turbine with an isolated diesel generation system are discussed. The machine configuration, its advantages and disadvantages and the machine performance and availability are discussed.
An element search ant colony technique for solving virtual machine placement problem
NASA Astrophysics Data System (ADS)
Srija, J.; Rani John, Rose; Kanaga, Grace Mary, Dr.
2017-09-01
The data centres in the cloud environment play a key role in providing infrastructure for ubiquitous computing, pervasive computing, mobile computing etc. This computing technique tries to utilize the available resources in order to provide services. Hence maintaining the resource utilization without wastage of power consumption has become a challenging task for the researchers. In this paper we propose the direct guidance ant colony system for effective mapping of virtual machines to the physical machine with maximal resource utilization and minimal power consumption. The proposed algorithm has been compared with the existing ant colony approach which is involved in solving virtual machine placement problem and thus the proposed algorithm proves to provide better result than the existing technique.
Analysis of Shield Construction in Spherical Weathered Granite Development Area
NASA Astrophysics Data System (ADS)
Cao, Quan; Li, Peigang; Gong, Shuhua
2018-01-01
The distribution of spherical weathered bodies (commonly known as "boulder") in the granite development area directly affects the shield construction of urban rail transit engineering. This paper is based on the case of shield construction of granite globular development area in Southern China area, the parameter control in shield machine selection and shield advancing during the shield tunneling in this special geological environment is analyzed. And it is suggested that shield machine should be selected for shield construction of granite spherical weathered zone. Driving speed, cutter torque, shield machine thrust, the amount of penetration and the speed of the cutter head of shield machine should be controlled when driving the boulder formation, in order to achieve smooth excavation and reduce the disturbance to the formation.
The 1980 Aircraft Safety and Operating Problems, part 1
NASA Technical Reports Server (NTRS)
Stickle, J. W. (Compiler)
1981-01-01
It is difficult to categorize aircraft operating problems, human factors and safety. Much of NASA's research involves all three and considers the important inter-relationships between man, the machine and the environment, whether the environment be man-made or natural. Topics covered in 20 papers include terminal-area operations; avionics and human factors; and the atmospheric environment.
An experimental evaluation of the REE SIFT environment for spaceborne applications
NASA Technical Reports Server (NTRS)
Whistnant, K.; Iyer, R. K.; Jones, P.; Some, R.; Rennels, D.
2002-01-01
This paper presents an experimental evaluation of a software-implemented fault tolerance environment built around a set of self-checking ARMOR proceses running on different machines that provide error detection and recovery services to themselves and to spaceborne scientific applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tikotekar, Anand A; Vallee, Geoffroy R; Naughton III, Thomas J
2008-01-01
The topic of system-level virtualization has recently begun to receive interest for high performance computing (HPC). This is in part due to the isolation and encapsulation offered by the virtual machine. These traits enable applications to customize their environments and maintain consistent software configurations in their virtual domains. Additionally, there are mechanisms that can be used for fault tolerance like live virtual machine migration. Given these attractive benefits to virtualization, a fundamental question arises, how does this effect my scientific application? We use this as the premise for our paper and observe a real-world scientific code running on a Xenmore » virtual machine. We studied the effects of running a radiative transfer simulation, Hydrolight, on a virtual machine. We discuss our methodology and report observations regarding the usage of virtualization with this application.« less
NASA Astrophysics Data System (ADS)
Bai, Ting; Sun, Kaimin; Deng, Shiquan; Chen, Yan
2018-03-01
High resolution image change detection is one of the key technologies of remote sensing application, which is of great significance for resource survey, environmental monitoring, fine agriculture, military mapping and battlefield environment detection. In this paper, for high-resolution satellite imagery, Random Forest (RF), Support Vector Machine (SVM), Deep belief network (DBN), and Adaboost models were established to verify the possibility of different machine learning applications in change detection. In order to compare detection accuracy of four machine learning Method, we applied these four machine learning methods for two high-resolution images. The results shows that SVM has higher overall accuracy at small samples compared to RF, Adaboost, and DBN for binary and from-to change detection. With the increase in the number of samples, RF has higher overall accuracy compared to Adaboost, SVM and DBN.
Pre-use anesthesia machine check; certified anesthesia technician based quality improvement audit.
Al Suhaibani, Mazen; Al Malki, Assaf; Al Dosary, Saad; Al Barmawi, Hanan; Pogoku, Mahdhav
2014-01-01
Quality assurance of providing a work ready machine in multiple theatre operating rooms in a tertiary modern medical center in Riyadh. The aim of the following study is to keep high quality environment for workers and patients in surgical operating rooms. Technicians based audit by using key performance indicators to assure inspection, passing test of machine worthiness for use daily and in between cases and in case of unexpected failure to provide quick replacement by ready to use another anesthetic machine. The anesthetic machines in all operating rooms are daily and continuously inspected and passed as ready by technicians and verified by anesthesiologist consultant or assistant consultant. The daily records of each machines were collected then inspected for data analysis by quality improvement committee department for descriptive analysis and report the degree of staff compliance to daily inspection as "met" items. Replaced machine during use and overall compliance. Distractive statistic using Microsoft Excel 2003 tables and graphs of sums and percentages of item studied in this audit. Audit obtained highest compliance percentage and low rate of replacement of machine which indicate unexpected machine state of use and quick machine switch. The authors are able to conclude that following regular inspection and running self-check recommended by the manufacturers can contribute to abort any possibility of hazard of anesthesia machine failure during operation. Furthermore in case of unexpected reason to replace the anesthesia machine in quick maneuver contributes to high assured operative utilization of man machine inter-phase in modern surgical operating rooms.
NASA Astrophysics Data System (ADS)
Johnson, Bradley; May, Gayle L.; Korn, Paula
The present conference discusses the currently envisioned goals of human-machine systems in spacecraft environments, prospects for human exploration of the solar system, and plausible methods for meeting human needs in space. Also discussed are the problems of human-machine interaction in long-duration space flights, remote medical systems for space exploration, the use of virtual reality for planetary exploration, the alliance between U.S. Antarctic and space programs, and the economic and educational impacts of the U.S. space program.
NASA Technical Reports Server (NTRS)
Kerr, Andrew W.
1989-01-01
Programs related to rotorcraft aeromechanics and man-machine integration are discussed which will support advanced army rotorcraft design. In aeromechanics, recent advances in computational fluid dynamics will be used to characterize the complex unsteady flowfields of rotorcraft, and a second-generation comprehensive helicopter analysis system will be used along with models of aerodynamics, engines, and control systems to study the structural dynamics of rotor/body configurations. The man-machine integration program includes the development of advanced cockpit design technology and the evaluation of cockpit and mission equipment concepts in a real-time full-combat environment.
2008-09-01
Abbreviations ATM automated teller machine BEA business enterprise architecture DOD...Limitations Automated Teller Machines (ATMs)-At-Sea 1988 Localized, shipboard ATMs that received and accounted for a portion of sailors’ and...use smart card technology for electronic retail ransactions and (2) economically justified on the basis of reliable analyses of stimated costs and
L.R. Iverson; A.M. Prasad; A. Liaw
2004-01-01
More and better machine learning tools are becoming available for landscape ecologists to aid in understanding species-environment relationships and to map probable species occurrence now and potentially into the future. To thal end, we evaluated three statistical models: Regression Tree Analybib (RTA), Bagging Trees (BT) and Random Forest (RF) for their utility in...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guan, Qiang
At exascale, the challenge becomes to develop applications that run at scale and use exascale platforms reliably, efficiently, and flexibly. Workflows become much more complex because they must seamlessly integrate simulation and data analytics. They must include down-sampling, post-processing, feature extraction, and visualization. Power and data transfer limitations require these analysis tasks to be run in-situ or in-transit. We expect successful workflows will comprise multiple linked simulations along with tens of analysis routines. Users will have limited development time at scale and, therefore, must have rich tools to develop, debug, test, and deploy applications. At this scale, successful workflows willmore » compose linked computations from an assortment of reliable, well-defined computation elements, ones that can come and go as required, based on the needs of the workflow over time. We propose a novel framework that utilizes both virtual machines (VMs) and software containers to create a workflow system that establishes a uniform build and execution environment (BEE) beyond the capabilities of current systems. In this environment, applications will run reliably and repeatably across heterogeneous hardware and software. Containers, both commercial (Docker and Rocket) and open-source (LXC and LXD), define a runtime that isolates all software dependencies from the machine operating system. Workflows may contain multiple containers that run different operating systems, different software, and even different versions of the same software. We will run containers in open-source virtual machines (KVM) and emulators (QEMU) so that workflows run on any machine entirely in user-space. On this platform of containers and virtual machines, we will deliver workflow software that provides services, including repeatable execution, provenance, checkpointing, and future proofing. We will capture provenance about how containers were launched and how they interact to annotate workflows for repeatable and partial re-execution. We will coordinate the physical snapshots of virtual machines with parallel programming constructs, such as barriers, to automate checkpoint and restart. We will also integrate with HPC-specific container runtimes to gain access to accelerators and other specialized hardware to preserve native performance. Containers will link development to continuous integration. When application developers check code in, it will automatically be tested on a suite of different software and hardware architectures.« less
Cripto-1 in Mammary Gland Development and Carcinogenesis
1998-06-01
and tested a hammerhead ribozyme [20, 37] that recognizes nucleotides 12-28 of the murine CR-I mRNA and cuts after the GUC triplet at nucleotides 18-20...UACACGG- 3’ "A UACICGG31 AAGGCC AUGUGCC-5’ IIII C AGCCGG U A G GA U FIG. 1. CR-l-specific hammerhead ribozyme . (A) Diagram of the processed CR-i mRNA...the CR-1 message and ribozyme is shown RT-PCR reactions were electrophoresed through 1.5% agarose-TAE in Figure 1A, and the folded hammerhead , bound
Cripto-1 in Mammary Gland Development and Carcinogenesis
1999-06-01
4). T.O. 2 We have designed and tested a hammerhead ribozyme [22, 23] that recognizes nucleotides 12-28 of the murine CR-I mRNA and cuts after the GUC...III C AGCCGG U A G GA U FIG. 1. CR-i-specific hammerhead ribozyme . (A) Diagram of the processed CR-1 mRNA, showing the ribozyme recognition sequence...diagram of the CR-1 message and ribozyme is shown RT-PCR reactions were electrophoresed through 1.5% agarose-TAE in Figure 1A, and the folded hammerhead
A Retrospective Analysis of the Carter Koreanization Plan: A Case Study of a Blurred Vision
1992-04-06
SS WD 0 A otrnD V19S9O WMAM Lietennt oloelHowrd .LIMEia Unte tae Am Best Available Copy UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE REPORT...long-standing, overriding aims of Kim Il Sung, the capricious and bellicose leader of the Democratic People’s Republic of Korea (DPRK), has been to...in Northeast Asia in gejneral and, given Kim Il Sung’s belligerence, on South Korean soil in particular. Since the outbreak of the Korean Wa-r the
A Least Cost Study for Book Procurement at the Naval Postgraduate School Library
1990-06-01
NAVAL POSTGRADUATE SCHOOL Monterey, California S7GR W DTIC &ELECTF ~jj N30 1 991TAES 0)0 THESIS B A LEAST COST STUDY FOR BOOK PROCUREMENT AT THE...Monterey, California 93943-5000 Monterey, California 93943-5000 C’ ’. z - I l a-, -.~,:IV A LEAST COST STUDY FOR BOOK PROCUREMENT AT THE NAVAL...Cost Study . , A . O -’U] aL’,"- ) t’ ’’- The primary objective of this thesis is to perform a cost effective- ness analysis of the various purchasing
NASA Technical Reports Server (NTRS)
Hussey, K. J.; Hall, J. R.; Mortensen, R. A.
1986-01-01
Image processing methods and software used to animate nonimaging remotely sensed data on cloud cover are described. Three FORTRAN programs were written in the VICAR2/TAE image processing domain to perform 3D perspective rendering, to interactively select parameters controlling the projection, and to interpolate parameter sets for animation images between key frames. Operation of the 3D programs and transferring the images to film is automated using executive control language and custom hardware to link the computer and camera.
Grinding and its influence to ground surface durability
NASA Astrophysics Data System (ADS)
Holesovsky, F.; Novak, M.
2011-01-01
A number of parameters of running process effect on the formed surface at grinding. Above all, the following influences can be mentioned: grinding wheel speed, workpiece speed, tool properties, rigidity of machine tool, etc. The plastic deformation and thermal load of surface layer are evoked at the action of cutting conditions. A new surface keeps the definite properties, which are given by its roughness, surface profile, geometry accuracy, intensity and residual stress distribution, respectively microhardness course in surface layer and changes of microstructure in this layer. The surface properties predict the surface behaviour in the real machinery at the dynamical, respectively static loading. At the load, the changes of surface properties proceed, e.g. roughness, residual stress. Simultaneously, changes of surface properties influence the durability of machine part and can also lead to surface damage and machine part breakdown. The slackness can also evoke the cracks, which leads to the fracture. The behaviour of part differs in the operating environment without and with oil or in the corrosion environment.
Advanced warfighter machine interface (Invited Paper)
NASA Astrophysics Data System (ADS)
Franks, Erin
2005-05-01
Future military crewmen may have more individual and shared tasks to complete throughout a mission as a result of smaller crew sizes and an increased number of technology interactions. To maintain reasonable workload levels, the Warfighter Machine Interface (WMI) must provide information in a consistent, logical manner, tailored to the environment in which the soldier will be completing their mission. This paper addresses design criteria for creating an advanced, multi-modal warfighter machine interface for on-the-move mounted operations. The Vetronics Technology Integration (VTI) WMI currently provides capabilities such as mission planning and rehearsal, voice and data communications, and manned/unmanned vehicle payload and mobility control. A history of the crewstation and more importantly, the WMI software will be provided with an overview of requirements and criteria used for completing the design. Multiple phases of field and laboratory testing provide the opportunity to evaluate the design and hardware in stationary and motion environments. Lessons learned related to system usability and user performance are presented with mitigation strategies to be tested in the future.
Johnson, Donna B.; Krieger, James; MacDougall, Erin; Payne, Elizabeth; Chan, Nadine L.
2015-01-01
Policies that change environments are important tools for preventing chronic diseases, including obesity. Boards of health often have authority to adopt such policies, but few do so. This study assesses 1) how one local board of health developed a policy approach for healthy food access through vending machine guidelines (rather than regulations) and 2) the impact of the approach. Using a case study design guided by “three streams” policy theory and RE-AIM, we analyzed data from a focus group, interviews, and policy documents. The guidelines effectively supported institutional policy development in several settings. Recognition of the problem of chronic disease and the policy solution of vending machine guidelines created an opening for the board to influence nutrition environments. Institutions identified a need for support in adopting vending machine policies. Communities could benefit from the study board’s approach to using nonregulatory evidence-based guidelines as a policy tool. PMID:25927606
Integrated flexible manufacturing program for manufacturing automation and rapid prototyping
NASA Technical Reports Server (NTRS)
Brooks, S. L.; Brown, C. W.; King, M. S.; Simons, W. R.; Zimmerman, J. J.
1993-01-01
The Kansas City Division of Allied Signal Inc., as part of the Integrated Flexible Manufacturing Program (IFMP), is developing an integrated manufacturing environment. Several systems are being developed to produce standards and automation tools for specific activities within the manufacturing environment. The Advanced Manufacturing Development System (AMDS) is concentrating on information standards (STEP) and product data transfer; the Expert Cut Planner system (XCUT) is concentrating on machining operation process planning standards and automation capabilities; the Advanced Numerical Control system (ANC) is concentrating on NC data preparation standards and NC data generation tools; the Inspection Planning and Programming Expert system (IPPEX) is concentrating on inspection process planning, coordinate measuring machine (CMM) inspection standards and CMM part program generation tools; and the Intelligent Scheduling and Planning System (ISAPS) is concentrating on planning and scheduling tools for a flexible manufacturing system environment. All of these projects are working together to address information exchange, standardization, and information sharing to support rapid prototyping in a Flexible Manufacturing System (FMS) environment.
NASA Astrophysics Data System (ADS)
Iwai, Go
2015-12-01
We describe the development of an environment for Geant4 consisting of an application and data that provide users with a more efficient way to access Geant4 applications without having to download and build the software locally. The environment is platform neutral and offers the users near-real time performance. In addition, the environment consists of data and Geant4 libraries built using low-level virtual machine (LLVM) tools which can produce bitcode that can be embedded in HTML and accessed via a browser. The bitcode is downloaded to the local machine via the browser and can then be configured by the user. This approach provides a way of minimising the risk of leaking potentially sensitive data used to construct the Geant4 model and application in the medical domain for treatment planning. We describe several applications that have used this approach and compare their performance with that of native applications. We also describe potential user communities that could benefit from this approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mcguckin, Theodore
2008-10-01
The Jefferson Lab Accelerator Controls Environment (ACE) was predominantly based on the HP-UX Unix platform from 1987 through the summer of 2004. During this period the Accelerator Machine Control Center (MCC) underwent a major renovation which included introducing Redhat Enterprise Linux machines, first as specialized process servers and then gradually as general login servers. As computer programs and scripts required to run the accelerator were modified, and inherent problems with the HP-UX platform compounded, more development tools became available for use with Linux and the MCC began to be converted over. In May 2008 the last HP-UX Unix login machinemore » was removed from the MCC, leaving only a few Unix-based remote-login servers still available. This presentation will explore the process of converting an operational Control Room environment from the HP-UX to Linux platform as well as the many hurdles that had to be overcome throughout the transition period (including a discussion of« less
NASA Astrophysics Data System (ADS)
Mia, Mozammel; Al Bashir, Mahmood; Dhar, Nikhil Ranjan
2016-10-01
Hard turning is increasingly employed in machining, lately, to replace time-consuming conventional turning followed by grinding process. An excessive amount of tool wear in hard turning is one of the main hurdles to be overcome. Many researchers have developed tool wear model, but most of them developed it for a particular work-tool-environment combination. No aggregate model is developed that can be used to predict the amount of principal flank wear for specific machining time. An empirical model of principal flank wear (VB) has been developed for the different hardness of workpiece (HRC40, HRC48 and HRC56) while turning by coated carbide insert with different configurations (SNMM and SNMG) under both dry and high pressure coolant conditions. Unlike other developed model, this model includes the use of dummy variables along with the base empirical equation to entail the effect of any changes in the input conditions on the response. The base empirical equation for principal flank wear is formulated adopting the Exponential Associate Function using the experimental results. The coefficient of dummy variable reflects the shifting of the response from one set of machining condition to another set of machining condition which is determined by simple linear regression. The independent cutting parameters (speed, rate, depth of cut) are kept constant while formulating and analyzing this model. The developed model is validated with different sets of machining responses in turning hardened medium carbon steel by coated carbide inserts. For any particular set, the model can be used to predict the amount of principal flank wear for specific machining time. Since the predicted results exhibit good resemblance with experimental data and the average percentage error is <10 %, this model can be used to predict the principal flank wear for stated conditions.
Learning in and from brain-based devices.
Edelman, Gerald M
2007-11-16
Biologically based mobile devices have been constructed that differ from robots based on artificial intelligence. These brain-based devices (BBDs) contain simulated brains that autonomously categorize signals from the environment without a priori instruction. Two such BBDs, Darwin VII and Darwin X, are described here. Darwin VII recognizes objects and links categories to behavior through instrumental conditioning. Darwin X puts together the "what,"when," and "where" from cues in the environment into an episodic memory that allows it to find a desired target. Although these BBDs are designed to provide insights into how the brain works, their principles may find uses in building hybrid machines. These machines would combine the learning ability of BBDs with explicitly programmed control systems.
NASA Astrophysics Data System (ADS)
Zhang, Ruiyun; Xu, Shisen; Cheng, Jian; Wang, Hongjian; Ren, Yongqiang
2017-07-01
Low-cost and high-performance matrix materials used in mass production of molten carbonate fuel cell (MCFC) were prepared by automatic casting machine with α-LiAlO2 powder material synthesized by gel-solid method, and distilled water as solvent. The single cell was assembled for generating test, and the good performance of the matrix was verified. The paper analyzed the factors affecting aqueous tape casting matrix preparation, such as solvent content, dispersant content, milling time, blade height and casting machine running speed, providing a solid basis for the mass production of large area environment-friendly matrix used in molten carbonate fuel cell.
Use of containerisation as an alternative to full virtualisation in grid environments.
NASA Astrophysics Data System (ADS)
Long, Robin
2015-12-01
Virtualisation is a key tool on the grid. It can be used to provide varying work environments or as part of a cloud infrastructure. Virtualisation itself carries certain overheads that decrease the performance of the system through requiring extra resources to virtualise the software and hardware stack, and CPU-cycles wasted instantiating or destroying virtual machines for each job. With the rise and improvements in containerisation, where only the software stack is kept separate and no hardware or kernel virtualisation is used, there is scope for speed improvements and efficiency increases over standard virtualisation. We compare containerisation and virtualisation, including a comparison against bare-metal machines as a benchmark.
Winston, Courtney P; Sallis, James F; Swartz, Michael D; Hoelscher, Deanna M; Peskin, Melissa F
2013-08-01
According to ecological models, the physical environment plays a major role in determining individual health behaviors. As such, researchers have started targeting the consumer nutrition environment of large-scale foodservice operations when implementing obesity-prevention programs. In 2010, the American Hospital Association released a call-to-action encouraging health care facilities to join in this movement and improve their facilities' consumer nutrition environments. The Hospital Nutrition Environment Scan (HNES) for Cafeterias, Vending Machines, and Gift Shops was developed in 2011, and the present study evaluated the inter-rater reliability of this instrument. Two trained raters visited 39 hospitals in southern California and completed the HNES. Percent agreement, kappa statistics, and intraclass correlation coefficients were calculated. Percent agreement between raters ranged from 74.4% to 100% and kappa statistics ranged from 0.458 to 1.0. The intraclass correlation coefficient for the overall nutrition composite scores was 0.961. Given these results, the HNES demonstrated acceptable reliability metrics and can now be disseminated to assess the current state of hospital consumer nutrition environments. Copyright © 2013 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
Stability Analysis of Radial Turning Process for Superalloys
NASA Astrophysics Data System (ADS)
Jiménez, Alberto; Boto, Fernando; Irigoien, Itziar; Sierra, Basilio; Suarez, Alfredo
2017-09-01
Stability detection in machining processes is an essential component for the design of efficient machining processes. Automatic methods are able to determine when instability is happening and prevent possible machine failures. In this work a variety of methods are proposed for detecting stability anomalies based on the measured forces in the radial turning process of superalloys. Two different methods are proposed to determine instabilities. Each one is tested on real data obtained in the machining of Waspalloy, Haynes 282 and Inconel 718. Experimental data, in both Conventional and High Pressure Coolant (HPC) environments, are set in four different states depending on materials grain size and Hardness (LGA, LGS, SGA and SGS). Results reveal that PCA method is useful for visualization of the process and detection of anomalies in online processes.
Parallel Computational Fluid Dynamics: Current Status and Future Requirements
NASA Technical Reports Server (NTRS)
Simon, Horst D.; VanDalsem, William R.; Dagum, Leonardo; Kutler, Paul (Technical Monitor)
1994-01-01
One or the key objectives of the Applied Research Branch in the Numerical Aerodynamic Simulation (NAS) Systems Division at NASA Allies Research Center is the accelerated introduction of highly parallel machines into a full operational environment. In this report we discuss the performance results obtained from the implementation of some computational fluid dynamics (CFD) applications on the Connection Machine CM-2 and the Intel iPSC/860. We summarize some of the experiences made so far with the parallel testbed machines at the NAS Applied Research Branch. Then we discuss the long term computational requirements for accomplishing some of the grand challenge problems in computational aerosciences. We argue that only massively parallel machines will be able to meet these grand challenge requirements, and we outline the computer science and algorithm research challenges ahead.
Machine vision and appearance based learning
NASA Astrophysics Data System (ADS)
Bernstein, Alexander
2017-03-01
Smart algorithms are used in Machine vision to organize or extract high-level information from the available data. The resulted high-level understanding the content of images received from certain visual sensing system and belonged to an appearance space can be only a key first step in solving various specific tasks such as mobile robot navigation in uncertain environments, road detection in autonomous driving systems, etc. Appearance-based learning has become very popular in the field of machine vision. In general, the appearance of a scene is a function of the scene content, the lighting conditions, and the camera position. Mobile robots localization problem in machine learning framework via appearance space analysis is considered. This problem is reduced to certain regression on an appearance manifold problem, and newly regression on manifolds methods are used for its solution.
Virtual Environment Training: Auxiliary Machinery Room (AMR) Watchstation Trainer.
ERIC Educational Resources Information Center
Hriber, Dennis C.; And Others
1993-01-01
Describes a project implemented at Newport News Shipbuilding that used Virtual Environment Training to improve the performance of submarine crewmen. Highlights include development of the Auxiliary Machine Room (AMR) Watchstation Trainer; Digital Video Interactive (DVI); screen layout; test design and evaluation; user reactions; authoring language;…
Walking robot: A design project for undergraduate students
NASA Technical Reports Server (NTRS)
1990-01-01
The design and construction of the University of Maryland walking machine was completed during the 1989 to 1990 academic year. It was required that the machine be capable of completing a number of tasks including walking a straight line, turning to change direction, and manuevering over an obstacle such as a set of stairs. The machine consists of two sets of four telescoping legs that alternately support the entire structure. A gear box and crank arm assembly is connected to the leg sets to provide the power required for the translational motion of the machine. By retracting all eight legs, the robot comes to rest on a central Bigfoot support. Turning is accomplished by rotating this machine about this support. The machine can be controlled by using either a user-operated remote tether or the onboard computer for the execution of control commands. Absolute encoders are attached to all motors to provide the control computer with information regarding the status of the motors. Long and short range infrared sensors provide the computer with feedback information regarding the machine's position relative to a series of stripes and reflectors. These infrared sensors simulate how the robot might sense and gain information about the environment of Mars.